  1. Solid-state flat panel imager with avalanche amorphous selenium

    Science.gov (United States)

    Scheuermann, James R.; Howansky, Adrian; Goldan, Amir H.; Tousignant, Olivier; Levéille, Sébastien; Tanioka, K.; Zhao, Wei

    2016-03-01

    Active matrix flat panel imagers (AMFPI) have become the dominant detector technology for digital radiography and fluoroscopy. For low dose imaging, electronic noise from the amorphous silicon thin film transistor (TFT) array degrades imaging performance. We have fabricated the first prototype solid-state AMFPI using a uniform layer of avalanche amorphous selenium (a-Se) photoconductor to amplify the signal to eliminate the effect of electronic noise. We have previously developed a large area solid-state avalanche a-Se sensor structure referred to as High Gain Avalanche Rushing Photoconductor (HARP) capable of achieving gains of 75. In this work we successfully deposited this HARP structure onto a 24 x 30 cm2 TFT array with a pixel pitch of 85 μm. An electric field (ESe) up to 105 Vμm-1 was applied across the a-Se layer without breakdown. Using the HARP layer as a direct detector, an X-ray avalanche gain of 15 +/- 3 was achieved at ESe = 105 Vμm-1. In indirect mode with a 150 μm thick structured CsI scintillator, an optical gain of 76 +/- 5 was measured at ESe = 105 Vμm-1. Image quality at low dose increases with the avalanche gain until the electronic noise is overcome at a constant exposure level of 0.76 mR. We demonstrate the success of a solid-state HARP X-ray imager as well as the largest active area HARP sensor to date.

  2. Amorphous selenium flat panel detectors for medical applications

    Science.gov (United States)

    Zhao, Wei; Hunt, D. C.; Tanioka, Kenkichi; Rowlands, J. A.

    2005-09-01

    Different technologies for making X-ray sensitive active matrix flat-panel imagers (AMFPI) are reviewed for applications in digital radiography and fluoroscopy. Aspects of imaging performance requiring improvement are identified and potential new detector concepts addressing these issues are briefly described. The rationale is given for the investigation of a new detector concept—an indirect conversion FPI with avalanche gain—for low-dose X-ray imaging. This detector consists of an amorphous selenium (a-Se) photoconductor optically coupled to a structured cesium iodide (CsI) scintillator. Under an electric field ESe, the a-Se is sensitive to light and converts the optical photons emitted from CsI into electronic signal that can be stored and read out in the same fashion as in existing AMFPI. When ESe is increased to >90 V/μm, avalanche multiplication occurs. The avalanche gain ranges between 1-800 depending on ESe and the thickness of the a-Se layer. The avalanche a-Se photoconductor is referred to as High-gain Avalanche Rushing amorphous Photoconductor. The feasibility of two detector configurations based on avalanche gain, each using a different image readout method, are under investigation. Their advantages are compared to other AMPFI technologies for digital radiography and fluoroscopy.

  3. Image performance of a new amorphous selenium flat panel x-ray detector designed for digital breast tomosynthesis

    Science.gov (United States)

    Cheung, L. K.; Jing, Z.; Bogdanovich, S.; Golden, K.; Robinson, S.; Beliaevskaia, E.; Parikh, S.

    2005-04-01

    The purpose of this work is to report the performance of an amorphous selenium (a-Se) based flat-panel x-ray imager under development for application in digital breast tomosynthesis. This detector is designed to perform both in the conventional Full Field Digital Mammography (FFDM) mode and the tomosynthesis mode. The large area 24 x 29 cm detector achieves rapid image acquisition rates of up to 4 frames per second with minimal trapped charge induced effects such as ghost or lag images of previously acquired objects. In this work, a new a-Se/TFT detector layer structure is evaluated. The design uses a top conductive layer in direct contact with the a-Se x-ray detection layer. The simple structure has few layers and minimal hole and electron trapping effects. Prototype detectors were built to investigate the basic image performance of this new a-Se/TFT detector. Image signal generation, image ghosting, image lag, and detector DQE were studied. For digital mammography applications, the residual image ghosting was less than 1% at 30 seconds elapsed time. DQE, measured at a field of 5.15 V/um, showed significantly higher values over previously reported data, especially at low exposure levels. For digital breast tomosynthesis, the image lag at dynamic readout rate was < 0.6 % at 0.5-second elapsed time. A prototype tomosynthesis system is being developed utilizing this new a-Se/TFT detector.

  4. Quantitative comparison using generalized relative object detectability (G-ROD) metrics of an amorphous selenium detector with high resolution microangiographic fluoroscopes (MAF) and standard flat panel detectors (FPD)

    Science.gov (United States)

    Russ, M.; Shankar, A.; Jain, A.; Setlur Nagesh, S. V.; Ionita, C. N.; Scott, C.; Karim, K. S.; Bednarek, D. R.; Rudin, S.

    2016-03-01

    A novel amorphous selenium (a-Se) direct detector with CMOS readout has been designed, and relative detector performance investigated. The detector features include a 25μm pixel pitch, and 1000μm thick a-Se layer operating at 10V/μm bias field. A simulated detector DQE was determined, and used in comparative calculations of the Relative Object Detectability (ROD) family of prewhitening matched-filter (PWMF) observer and non-pre-whitening matched filter (NPWMF) observer model metrics to gauge a-Se detector performance against existing high resolution micro-angiographic fluoroscopic (MAF) detectors and a standard flat panel detector (FPD). The PWMF-ROD or ROD metric compares two x-ray imaging detectors in their relative abilities in imaging a given object by taking the integral over spatial frequencies of the Fourier transform of the detector DQE weighted by an object function, divided by the comparable integral for a different detector. The generalized-ROD (G-ROD) metric incorporates clinically relevant parameters (focal- spot size, magnification, and scatter) to show the degradation in imaging performance for detectors that are part of an imaging chain. Preliminary ROD calculations using simulated spheres as the object predicted superior imaging performance by the a-Se detector as compared to existing detectors. New PWMF-G-ROD and NPWMF-G-ROD results still indicate better performance by the a-Se detector in an imaging chain over all sphere sizes for various focal spot sizes and magnifications, although a-Se performance advantages were degraded by focal spot blurring. Nevertheless, the a-Se technology has great potential to provide break- through abilities such as visualization of fine details including of neuro-vascular perforator vessels and of small vascular devices.

  5. Image quality vs. radiation dose for a flat-panel amorphous silicon detector: a phantom study.

    Science.gov (United States)

    Geijer, H; Beckman, K W; Andersson, T; Persliden, J

    2001-01-01

    The aim of this study was to investigate the image quality for a flat-panel amorphous silicon detector at various radiation dose settings and to compare the results with storage phosphor plates and a screen-film system. A CDRAD 2.0 contrast-detail phantom was imaged with a flat-panel detector (Philips Medical Systems, Eindhoven, The Netherlands) at three different dose levels with settings for intravenous urography. The same phantom was imaged with storage phosphor plates at a simulated system speed of 200 and a screen-film system with a system speed of 160. Entrance surface doses were recorded for all images. At each setting, three images were read by four independent observers. The flat-panel detector had equal image quality at less than half the radiation dose compared with storage phosphor plates. The difference was even larger when compared with film with the flat-panel detector having equal image quality at approximately one-fifth the dose. The flat-panel detector has a very favourable combination of image quality vs radiation dose compared with storage phosphor plates and screen film.

  6. Image quality vs radiation dose for a flat-panel amorphous silicon detector: a phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Geijer, H.; Andersson, T. [Dept. of Radiology, Oerebro Medical Centre Hospital (Sweden); Beckman, K.W.; Persliden, J. [Dept. of Medical Physics, Oerebro Medical Centre Hospital (Sweden)

    2001-09-01

    The aim of this study was to investigate the image quality for a flat-panel amorphous silicon detector at various radiation dose settings and to compare the results with storage phosphor plates and a screen-film system. A CDRAD 2.0 contrast-detail phantom was imaged with a flat-panel detector (Philips Medical Systems, Eindhoven, The Netherlands) at three different dose levels with settings for intravenous urography. The same phantom was imaged with storage phosphor plates at a simulated system speed of 200 and a screen-film system with a system speed of 160. Entrance surface doses were recorded for all images. At each setting, three images were read by four independent observers. The flat-panel detector had equal image quality at less than half the radiation dose compared with storage phosphor plates. The difference was even larger when compared with film with the flat-panel detector having equal image quality at approximately one-fifth the dose. The flat-panel detector has a very favourable combination of image quality vs radiation dose compared with storage phosphor plates and screen film. (orig.)

  7. Amorphous and Polycrystalline Photoconductors for Direct Conversion Flat Panel X-Ray Image Sensors

    Directory of Open Access Journals (Sweden)

    Karim S. Karim

    2011-05-01

    Full Text Available In the last ten to fifteen years there has been much research in using amorphous and polycrystalline semiconductors as x-ray photoconductors in various x-ray image sensor applications, most notably in flat panel x-ray imagers (FPXIs. We first outline the essential requirements for an ideal large area photoconductor for use in a FPXI, and discuss how some of the current amorphous and polycrystalline semiconductors fulfill these requirements. At present, only stabilized amorphous selenium (doped and alloyed a-Se has been commercialized, and FPXIs based on a-Se are particularly suitable for mammography, operating at the ideal limit of high detective quantum efficiency (DQE. Further, these FPXIs can also be used in real-time, and have already been used in such applications as tomosynthesis. We discuss some of the important attributes of amorphous and polycrystalline x-ray photoconductors such as their large area deposition ability, charge collection efficiency, x-ray sensitivity, DQE, modulation transfer function (MTF and the importance of the dark current. We show the importance of charge trapping in limiting not only the sensitivity but also the resolution of these detectors. Limitations on the maximum acceptable dark current and the corresponding charge collection efficiency jointly impose a practical constraint that many photoconductors fail to satisfy. We discuss the case of a-Se in which the dark current was brought down by three orders of magnitude by the use of special blocking layers to satisfy the dark current constraint. There are also a number of polycrystalline photoconductors, HgI2 and PbO being good examples, that show potential for commercialization in the same way that multilayer stabilized a-Se x-ray photoconductors were developed for commercial applications. We highlight the unique nature of avalanche multiplication in a-Se and how it has led to the development of the commercial HARP video-tube. An all solid state version of the

  8. Amorphous and polycrystalline photoconductors for direct conversion flat panel x-ray image sensors.

    Science.gov (United States)

    Kasap, Safa; Frey, Joel B; Belev, George; Tousignant, Olivier; Mani, Habib; Greenspan, Jonathan; Laperriere, Luc; Bubon, Oleksandr; Reznik, Alla; DeCrescenzo, Giovanni; Karim, Karim S; Rowlands, John A

    2011-01-01

    In the last ten to fifteen years there has been much research in using amorphous and polycrystalline semiconductors as x-ray photoconductors in various x-ray image sensor applications, most notably in flat panel x-ray imagers (FPXIs). We first outline the essential requirements for an ideal large area photoconductor for use in a FPXI, and discuss how some of the current amorphous and polycrystalline semiconductors fulfill these requirements. At present, only stabilized amorphous selenium (doped and alloyed a-Se) has been commercialized, and FPXIs based on a-Se are particularly suitable for mammography, operating at the ideal limit of high detective quantum efficiency (DQE). Further, these FPXIs can also be used in real-time, and have already been used in such applications as tomosynthesis. We discuss some of the important attributes of amorphous and polycrystalline x-ray photoconductors such as their large area deposition ability, charge collection efficiency, x-ray sensitivity, DQE, modulation transfer function (MTF) and the importance of the dark current. We show the importance of charge trapping in limiting not only the sensitivity but also the resolution of these detectors. Limitations on the maximum acceptable dark current and the corresponding charge collection efficiency jointly impose a practical constraint that many photoconductors fail to satisfy. We discuss the case of a-Se in which the dark current was brought down by three orders of magnitude by the use of special blocking layers to satisfy the dark current constraint. There are also a number of polycrystalline photoconductors, HgI(2) and PbO being good examples, that show potential for commercialization in the same way that multilayer stabilized a-Se x-ray photoconductors were developed for commercial applications. We highlight the unique nature of avalanche multiplication in a-Se and how it has led to the development of the commercial HARP video-tube. An all solid state version of the HARP has been

  9. Full breast digital mammography with an amorphous silicon-based flat panel detector: Physical characteristics of a clinical prototype

    OpenAIRE

    2000-01-01

    The physical characteristics of a clinical prototype amorphous silicon-based flat panel imager for full-breast digital mammography have been investigated. The imager employs a thin thallium doped CsI scintillator on an amorphous silicon matrix of detector elements with a pixel pitch of 100 μm. Objective criteria such as modulation transfer function (MTF), noise power spectrum, detective quantum efficiency (DQE), and noise equivalent quanta were employed for this evaluation. The presampling MT...

  10. Multidetector-row CT with a 64-row amorphous silicon flat panel detector

    Science.gov (United States)

    Shapiro, Edward G.; Colbeth, Richard E.; Daley, Earl T.; Job, Isaias D.; Mollov, Ivan P.; Mollov, Todor I.; Pavkovich, John M.; Roos, Pieter G.; Star-Lack, Josh M.; Tognina, Carlo A.

    2007-03-01

    A unique 64-row flat panel (FP) detector has been developed for sub-second multidetector-row CT (MDCT). The intent was to explore the image quality achievable with relatively inexpensive amorphous silicon (a-Si) compared to existing diagnostic scanners with discrete crystalline diode detectors. The FP MDCT system is a bench-top design that consists of three FP modules. Each module uses a 30 cm x 3.3 cm a-Si array with 576 x 64 photodiodes. The photodiodes are 0.52 mm x 0.52 mm, which allows for about twice the spatial resolution of most commercial MDCT scanners. The modules are arranged in an overlapping geometry, which is sufficient to provide a full-fan 48 cm diameter scan. Scans were obtained with various detachable scintillators, e.g. ceramic Gd IIO IIS, particle-in-binder Gd IIO IIS:Tb and columnar CsI:Tl. Scan quality was evaluated with a Catphan-500 performance phantom and anthropomorphic phantoms. The FP MDCT scans demonstrate nearly equivalent performance scans to a commercial 16-slice MDCT scanner at comparable 10 - 20 mGy/100mAs doses. Thus far, a high contrast resolution of 15 lp/cm and a low contrast resolution of 5 mm @ 0.3 % have been achieved on 1 second scans. Sub-second scans have been achieved with partial rotations. Since the future direction of MDCT appears to be in acquiring single organ coverage per scan, future efforts are planned for increasing the number of detector rows beyond the current 64- rows.

  11. Characterization and application of a GE amorphous silicon flat panel detector in a synchrotron light source

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J.H. [XSD Advanced Photon Source, Argonne National Laboratory (United States)], E-mail: jlee@aps.anl.gov; Almer, J. [XSD Advanced Photon Source, Argonne National Laboratory (United States); Aydiner, C. [Los Alamos National Laboratory (United States); Bernier, J.; Chapman, K.; Chupas, P.; Haeffner, D. [XSD Advanced Photon Source, Argonne National Laboratory (United States); Kump, K. [GE Healthcare (United States); Lee, P.L.; Lienert, U.; Miceli, A. [XSD Advanced Photon Source, Argonne National Laboratory (United States); Vera, G. [GE Healthcare (United States)

    2007-11-11

    Characterization, in the language of synchrotron radiation, was performed on a GE Revolution 41RT flat panel detector using the X-ray light source at the Advanced Photon Source (APS). The detector has an active area of 41x41 cm{sup 2} with 200x200 {mu}m{sup 2} pixel size. The nominal working photon energy is around 80 keV. Modulation transfer function (MTF) was measured in terms of line spread function (LSF) using a 25 {mu}mx1 cm tungsten slit. Memory effects of the detector elements, called lag, were also measured. The large area and fast data capturing rate -8 fps in unbinned mode, 30 fps in binned or region of interest (ROI) mode-make the GE flat panel detector a unique and very versatile detector for synchrotron experiments. In particular, we present data from pair distribution function (PDF) measurements to demonstrate the special features of this detector.

  12. Full breast digital mammography with an amorphous silicon-based flat panel detector: physical characteristics of a clinical prototype.

    Science.gov (United States)

    Vedantham, S; Karellas, A; Suryanarayanan, S; Albagli, D; Han, S; Tkaczyk, E J; Landberg, C E; Opsahl-Ong, B; Granfors, P R; Levis, I; D'Orsi, C J; Hendrick, R E

    2000-03-01

    The physical characteristics of a clinical prototype amorphous silicon-based flat panel imager for full-breast digital mammography have been investigated. The imager employs a thin thallium doped CsI scintillator on an amorphous silicon matrix of detector elements with a pixel pitch of 100 microm. Objective criteria such as modulation transfer function (MTF), noise power spectrum, detective quantum efficiency (DQE), and noise equivalent quanta were employed for this evaluation. The presampling MTF was found to be 0.73, 0.42, and 0.28 at 2, 4, and 5 cycles/mm, respectively. The measured DQE of the current prototype utilizing a 28 kVp, Mo-Mo spectrum beam hardened with 4.5 cm Lucite is approximately 55% at close to zero spatial frequency at an exposure of 32.8 mR, and decreases to approximately 40% at a low exposure of 1.3 mR. Detector element nonuniformity and electronic gain variations were not significant after appropriate calibration and software corrections. The response of the imager was linear and did not exhibit signal saturation under tested exposure conditions.

  13. Design and performance of the prototype full field breast tomosynthesis system with selenium based flat panel detector

    Science.gov (United States)

    Ren, Baorui; Ruth, Chris; Stein, Jay; Smith, Andrew; Shaw, Ian; Jing, Zhenxue

    2005-04-01

    We have developed a breast tomosynthesis system utilizing a selenium-based direct conversion flat panel detector. This prototype system is a modification of Selenia, Hologic"s full field digital mammography system, using an add-on breast holding device to allow 3D tomosynthetic imaging. During a tomosynthesis scan, the breast is held stationary while the x-ray source and detector mounted on a c-arm rotate continuously around the breast over an angular range up to 30 degrees. The x-ray tube is pulsed to acquire 11 projections at desired c-arm angles. Images are reconstructed in planes parallel to the breastplate using a filtered backprojection algorithm. Processing time is typically 1 minute for a 50 mm thick breast at 0.1 mm in-plane pixel size, 1 mm slice-to-slice separation. Clinical studies are in progress. Performance evaluations were carried out at the system and the subsystem levels including spatial resolution, signal-to-noise ratio, spectra optimization, imaging technique, and phantom and patient studies. Experimental results show that we have successfully built a tomosynthesis system with images showing less structure noise and revealing 3D information compared with the conventional mammogram. We introduce, for the first time, the definition of "Depth of Field" for tomosynthesis based on a spatial resolution study. This parameter is used together with Modulation Transfer Function (MTF) to evaluate 3D resolution of a tomosynthesis system as a function of system design, imaging technique, and reconstruction algorithm. Findings from the on-going clinical studies will help the design of the next generation tomosynthesis system offering improved performance.

  14. Plasma technology and its use in flat panel digital radiography.

    Science.gov (United States)

    Zur, Albert

    2010-01-01

    Plasma DR technology is used to produce a cost effective flat panel x-ray detector that acquires digital x-ray images with excellent diagnostic quality. The detector is radiation hard and permanently zero defect, with a full virtual pixel matrix that has no dead lines, pixels, or dead pixel clusters. The technology also allows the full potential of large area amorphous Selenium imaging to finally be realized (see Figure 4).

  15. Performance of a 41X41-cm2 amorphous silicon flat panel x-ray detector for radiographic imaging applications.

    Science.gov (United States)

    Granfors, P R; Aufrichtig, R

    2000-06-01

    We report the performance of a 41 X 41-cm2 amorphous silicon-based flat panel detector designed for radiographic imaging applications. The detector consists of an array of photodiodes and thin film transistor switches on a 0.2-mm pitch with an overlying thallium-doped cesium iodide scintillator. The performance of the detector was evaluated through measurement of the frequency-dependent detective quantum efficiency [DQE(f)]. Measurements of the characteristic curve and modulation transfer function (MTF) are also reported. All measurements were made in a radiographic imaging mode with a readout time of 125 ms. We evaluated a total of 15 detectors. One detector was characterized at a range of exposures and at three different electronic gain settings. Measurements of DQE(f) and MTF were also performed as a function of position on one detector. The measured DQE at an exposure of about 1 mR was 0.66 at zero spatial frequency and fell smoothly with frequency to a value of 0.24 at the Nyquist frequency, 2.5 cycles/mm. The DQE is independent of exposure for exposures in the upper 80% of each gain range, but is reduced somewhat at lower exposures because of the influence of additive system noise. The reduction can be controlled by adjusting the electronic gain. For a gain that allows a maximum exposure of 5 mR, the DQE at 0.056 mR was 0.64 at zero frequency and 0.19 at 2.5 cycles/mm. The standard deviation in DQE among measurements on different detectors was less than 0.02 at any frequency. The presampling MTF was 0.26 at 2.5 cycles/mm. The standard deviation in MTF among measurements on different detectors was less than 0.01 at any frequency. Both MTF and DQE were substantially independent of position on the detector.

  16. Fracture Phenomena in Amorphous Selenium

    DEFF Research Database (Denmark)

    Lindegaard-Andersen, Asger; Dahle, Birgit

    1966-01-01

    the velocities of ultrasonic longitudinal and shear waves were measured to 1820 m/sec and 930 m/sec, respectively. Based on these results the two line systems in the transition zone can be interpreted as ``Wallner lines'' with sources within the zone. ©1966 The American Institute of Physics......Fracture surfaces of amorphous selenium broken in flexure at room temperature have been studied. The fracture velocity was found to vary in different regions of the fracture surface. Peculiar features were observed in a transition zone between fast and slower fracture. In this zone cleavage steps...

  17. Development of an amorphous selenium-based photodetector driven by a diamond cold cathode.

    Science.gov (United States)

    Masuzawa, Tomoaki; Saito, Ichitaro; Yamada, Takatoshi; Onishi, Masanori; Yamaguchi, Hisato; Suzuki, Yu; Oonuki, Kousuke; Kato, Nanako; Ogawa, Shuichi; Takakuwa, Yuji; Koh, Angel T T; Chua, Daniel H C; Mori, Yusuke; Shimosawa, Tatsuo; Okano, Ken

    2013-10-11

    Amorphous-selenium (a-Se) based photodetectors are promising candidates for imaging devices, due to their high spatial resolution and response speed, as well as extremely high sensitivity enhanced by an internal carrier multiplication. In addition, a-Se is reported to show sensitivity against wide variety of wavelengths, including visible, UV and X-ray, where a-Se based flat-panel X-ray detector was proposed. In order to develop an ultra high-sensitivity photodetector with a wide detectable wavelength range, a photodetector was fabricated using a-Se photoconductor and a nitrogen-doped diamond cold cathode. In the study, a prototype photodetector has been developed, and its response to visible and ultraviolet light are characterized.

  18. Comparative Analysis between Two Amorphous Silicon Flat-panel Detector:Radiation Dose and Image Quality%碘化铯和硫氯化钆在DR系统中剂量与图像质量的分析

    Institute of Scientific and Technical Information of China (English)

    张志奎; 梁吉

    2014-01-01

    目的:比较碘化铯和硫氧化钆2种闪烁体材料平板探测器的DR系统在不同成像剂量条件下图像质量的差别。方法:以碘化铯为闪烁体材料的平板探测器系统和以硫氧化钆为闪烁体材料的平板探测器系统分别摄取对比度-细节体模(CDRAD 2.0)在相近成像剂量条件下的X射线图像,计算所对应的成像剂量下图像质量因子反数值(image quality figure inverse,IQFinv),应用ANOVA分析2平板探测器对比度及细节检测能力,应用Wilcoxon检验分析、比较2种平板探测器的图像信息检测能力的差别。结果:在一定剂量范围内,2种平板探测器的图像质量均随着成像剂量的增加而增加(P<0.001)。在管电流量不同mAs时,2种非晶硅DR平板探测器的IQFinv值差异无统计学意义(P>0.05)。结论:成像剂量相同时,2种非晶硅平板探测器具有近似的图像质量,图像质量的提高与成像剂量的增加并不成线性关系。%Objective:To assess and compare the image quality at different exposures ettings using cesium iodide (CsI) flat-panel detector digital radiography system and GOS flat-panel detector digital radiography system. Methods: The images of contrast-detail phantom (CDRAD2.0) were taken at different exposure settings for two flat-panel detector systems. The image quality figure inverse (IQFinv) for different dose settings was calculated. The detectability of two system in contrast and detail was analysed using ANOVA. The statistical significance was evaluated using the Wilcoxon test between two system. Results: At certain dose range, the image quality improved with radiation dose increased for two amorphous silicon flat-panel detector system(P0.05). Conclusion:At the same radiation dose, two flat-panel detector systems have approximately image quality. There is not linear relevance between image quality improvement and radiation dose augment.

  19. Comparative Analysis between Two Amorphous Silicon Flat-panel Detector: Radiation Dose and Image Quality%2种非晶硅DR平板探测器成像剂量与图像质量的比较分析

    Institute of Scientific and Technical Information of China (English)

    曹国全; 许化致; 潘克华; 孙厚长

    2011-01-01

    Objective To assess and compare the image quality at different exposure settings using cesium iodide (CsI) flat-panel detector digital radiography system and GOS flat-panel detector digital radiography system. Methods The images of contrast-detail phantom (CDRAD2. 0) were taken at different exposure settings for two flat-panel detector systems. The image quality figure inverse(IQFinv) for different dose settings was calculated. The detectability of two system in contrast and detail was analysed using ANOVA . The statistical significance was evaluated using the Wilcoxon test between two system. Results At certain dose range, the image quality improved with radiation dose increased for two amorphous silicon flat-panel detector system(P<O. 001). At different mAs value of tube current dosage,the IQFinv was no of statistical significance between two system(P>O. 05). Conclusion At the same radiation dose,two flat-panel detector systems have approximately image quality. There is not linear relevance between image quality improvement and radiation dose augment.%目的 比较碘化铯和硫氧化钆2种闪烁体材料平板探测器的DR系统在不同成像剂量条件下图像质量的差别.方法 以碘化铯为闪烁体材料的平板探测器系统和以硫氧化钆为闪烁体材料的平板探测器系统分别摄取对比度-细节体模(CDRAD 2.0)在相近成像剂量条件下的X射线图像,计算所对应的成像剂量下图像质量因子反数值(image quality figure inverse,IQFinv),应用ANOVA 分析2平板探测器对比度及细节检测能力,应用Wilcoxon检验分析、比较2种平板探测器的图像信息检测能力的差别.结果 在一定剂量范围内,2种平板探测器的图像质量均随着成像剂量的增加而增加(P<0.001).在管电流量不同mAs时,2种非晶硅DR平板探测器的IQFinv值差异无统计学意义(P>0.05).结论 成像剂量相同时,2种非晶硅平板探测器具有近似的图像质量,图像质量的

  20. Flat panel display - Impurity doping technology for flat panel displays

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Toshiharu [Advanced Technology Planning, Sumitomo Eaton Nova Corporation, SBS Tower 9F, 10-1, Yoga 4-chome, Setagaya-ku, 158-0097 Tokyo (Japan)]. E-mail: suzuki_tsh@senova.co.jp

    2005-08-01

    Features of the flat panel displays (FPDs) such as liquid crystal display (LCD) and organic light emitting diode (OLED) display, etc. using low temperature poly-Si (LTPS) thin film transistors (TFTs) are briefly reviewed comparing with other FPDs. The requirements for fabricating TFTs used for high performance FPDs and system on glass (SoG) are addressed. This paper focuses on the impurity doping technology, which is one of the key technologies together with crystallization by laser annealing, formation of high quality gate insulator and gate-insulator/poly-Si interface. The issues to be solved in impurity doping technology for state of the art and future TFTs are clarified.

  1. Digital flat-panel X-ray technology based on cesium iodide and amorphous silicon: experimental studies and preliminary clinical results; Digitale Flachbilddetektortechnik basierend auf Caesiumjodid und amorphem Silizium: Experimentelle Untersuchungen und erste klinische Ergebnisse

    Energy Technology Data Exchange (ETDEWEB)

    Strotzer, M.; Gmeinwieser, J.; Voelk, M.; Fruend, R.; Feuerbach, S. [Regensburg Univ. (Germany). Inst. fuer Roentgendiagnostik

    1999-01-01

    Purpose: Experimental and clinical evaluation of a digital flat-panel X-ray system based on cesium iodide (CsI) and amorphous silicon (a-Si). Methods: Performance of a prototype detector was compared with conventional screen-film radiography (SFR) using several phantom studies. Foreign bodies, fractures, osteolyses, and pulmonary lesions were analyzed. Additionally, 120 patients were studied prospectively, resulting in 400 comparative X-ray studies. The flat-panel detector was exposed with standard dose and with a dose reduction of up to 75%. Detector size was 15x15 cm, pixel matrix was 1x1 k with a pixel size of 143 {mu}m. Modulation-transfer function was determined to be 18% at the maximum spatial resolution of 3.5 Ip/mm. Results: The diagnostic results achieved with the digital detector were similar to those of conventional SFR, even at reduced radiation exposure. A potential for dose reduction was observed: 50% with respect to osteoarthrosis and fractures, and 75% for determining bony alignment. Discussion: This new technology can be used in thoracic and skeletal radiography. A significant dose reduction is possible, depending on the suspected disease. (orig.) [Deutsch] Ziel: Experimentelle und klinische Pruefung eines digitalen Flachbilddetektors aus Caesiumjodid (CsJ) und amorphem Silizium (a-Si). Methoden: Mit Hilfe verschiedener Phantommodelle wurde ein Detektor-Prototyp mit konventionellen Folien-Filmsystemen (FFS) verglichen. Untersucht wurden die Nachweisbarkeit von Fremdkoerpern, Frakturen, Osteolysen und artefiziellen pulmonalen Laesionen. Zusaetzlich erfolgten prospektiv an 120 Patienten insgesamt 400 vergleichende Skelettuntersuchungen. Der Flachbilddetektor wurde mit identischer Dosis bzw. mit um bis zu 75% reduzierter Dosis belichtet. Seine aktive Flaeche betrug ca. 15x15 cm bei einer Pixelmatrix von 1x1 k und eine Pixelgroesse von 143 {mu}m. Bei der Grenzaufloesung von 3,5 Lp/mm betrug der Wert der Modulationsuebertragungsfunktion 18%. Ergebnisse

  2. X-ray imaging using avalanche multiplication in amorphous selenium: investigation of depth dependent avalanche noise.

    Science.gov (United States)

    Hunt, D C; Tanioka, Kenkichi; Rowlands, J A

    2007-03-01

    The past decade has seen the swift development of the flat-panel detector (FPD), also known as the active matrix flat-panel imager, for digital radiography. This new technology is applicable to other modalities, such as fluoroscopy, which require the acquisition of multiple images, but could benefit from some improvements. In such applications where more than one image is acquired less radiation is available to form each image and amplifier noise becomes a serious problem. Avalanche multiplication in amorphous selenium (a-Se) can provide the necessary amplification prior to read out so as to reduce the effect of electronic noise of the FPD. However, in direct conversion detectors avalanche multiplication can lead to a new source of gain fluctuation noise called depth dependent avalanche noise. A theoretical model was developed to understand depth dependent avalanche noise. Experiments were performed on a direct imaging system implementing avalanche multiplication in a layer of a-Se to validate the theory. For parameters appropriate for a diagnostic imaging FPD for fluoroscopy the detective quantum efficiency (DQE) was found to drop by as much as 50% with increasing electric field, as predicted by the theoretical model. This drop in DQE can be eliminated by separating the collection and avalanche regions. For example by having a region of low electric field where x rays are absorbed and converted into charge that then drifts into a region of high electric field where the x-ray generated charge undergoes avalanche multiplication. This means quantum noise limited direct conversion FPD for low exposure imaging techniques are a possibility.

  3. Laser illuminated flat panel display

    Energy Technology Data Exchange (ETDEWEB)

    Veligdan, J.T.

    1995-12-31

    A 10 inch laser illuminated flat panel Planar Optic Display (POD) screen has been constructed and tested. This POD screen technology is an entirely new concept in display technology. Although the initial display is flat and made of glass, this technology lends itself to applications where a plastic display might be wrapped around the viewer. The display screen is comprised of hundreds of planar optical waveguides where each glass waveguide represents a vertical line of resolution. A black cladding layer, having a lower index of refraction, is placed between each waveguide layer. Since the cladding makes the screen surface black, the contrast is high. The prototype display is 9 inches wide by 5 inches high and approximately I inch thick. A 3 milliwatt HeNe laser is used as the illumination source and a vector scanning technique is employed.

  4. Indirect flat-panel detector with avalanche gain: fundamental feasibility investigation for SHARP-AMFPI (scintillator HARP active matrix flat panel imager).

    Science.gov (United States)

    Zhao, Wei; Li, Dan; Reznik, Alla; Lui, B J M; Hunt, D C; Rowlands, J A; Ohkawa, Yuji; Tanioka, Kenkichi

    2005-09-01

    An indirect flat-panel imager (FPI) with avalanche gain is being investigated for low-dose x-ray imaging. It is made by optically coupling a structured x-ray scintillator CsI(Tl) to an amorphous selenium (a-Se) avalanche photoconductor called HARP (high-gain avalanche rushing photoconductor). The final electronic image is read out using an active matrix array of thin film transistors (TFT). We call the proposed detector SHARP-AMFPI (scintillator HARP active matrix flat panel imager). The advantage of the SHARP-AMFPI is its programmable gain, which can be turned on during low dose fluoroscopy to overcome electronic noise, and turned off during high dose radiography to avoid pixel saturation. The purpose of this paper is to investigate the important design considerations for SHARP-AMFPI such as avalanche gain, which depends on both the thickness d(Se) and the applied electric field E(Se) of the HARP layer. To determine the optimal design parameter and operational conditions for HARP, we measured the E(Se) dependence of both avalanche gain and optical quantum efficiency of an 8 microm HARP layer. The results were used in a physical model of HARP as well as a linear cascaded model of the FPI to determine the following x-ray imaging properties in both the avalanche and nonavalanche modes as a function of E(Se): (1) total gain (which is the product of avalanche gain and optical quantum efficiency); (2) linearity; (3) dynamic range; (4) gain nonuniformity resulting from thickness nonuniformity; and (5) effects of direct x-ray interaction in HARP. Our results showed that a HARP layer thickness of 8 microm can provide adequate avalanche gain and sufficient dynamic range for x-ray imaging applications to permit quantum limited operation over the range of exposures needed for radiography and fluoroscopy.

  5. Feasibility of Amorphous Selenium Based Photon Counting Detectors for Digital Breast Tomosynthesis

    Energy Technology Data Exchange (ETDEWEB)

    Chen, J.; O' Connor, P.; Lehnert, J., De Geronimo, G., Dolazza, E., Tousignant, O., Laperriere, L., Greenspan, J., Zhao, W.

    2009-02-27

    Amorphous selenium (a-Se) has been incorporated successfully in direct conversion flat panel x-ray detectors, and has demonstrated superior image quality in screening mammography and digital breast tomosynthesis (DBT) under energy integration mode. The present work explores the potential of a-Se for photon counting detectors in DBT. We investigated major factors contributing to the variation in the charge collected by a pixel upon absorption of each x-ray photon. These factors included x-ray photon interaction, detector geometry, charge transport, and the pulse shaping and noise properties of the photon counting readout circuit. Experimental measurements were performed on a linear array test structure constructed by evaporating an a-Se layer onto an array of 100 {mu}m pitch strip electrodes, which are connected to a 32 channel low noise photon counting integrated circuit. The measured pulse height spectrum (PHS) under polychromatic xray exposure was interpreted quantitatively using the factors identified. Based on the understanding of a-Se photon counting performance, design parameters were proposed for a 2D detector with high quantum efficiency and count rate that could meet the requirements of photon counting detector for DBT.

  6. Low dose digital X-ray imaging with avalanche amorphous selenium

    Science.gov (United States)

    Scheuermann, James R.; Goldan, Amir H.; Tousignant, Olivier; Léveillé, Sébastien; Zhao, Wei

    2015-03-01

    Active Matrix Flat Panel Imagers (AMFPI) based on an array of thin film transistors (TFT) have become the dominant technology for digital x-ray imaging. In low dose applications, the performance of both direct and indirect conversion detectors are limited by the electronic noise associated with the TFT array. New concepts of direct and indirect detectors have been proposed using avalanche amorphous selenium (a-Se), referred to as high gain avalanche rushing photoconductor (HARP). The indirect detector utilizes a planar layer of HARP to detect light from an x-ray scintillator and amplify the photogenerated charge. The direct detector utilizes separate interaction (non-avalanche) and amplification (avalanche) regions within the a-Se to achieve depth-independent signal gain. Both detectors require the development of large area, solid state HARP. We have previously reported the first avalanche gain in a-Se with deposition techniques scalable to large area detectors. The goal of the present work is to demonstrate the feasibility of large area HARP fabrication in an a-Se deposition facility established for commercial large area AMFPI. We also examine the effect of alternative pixel electrode materials on avalanche gain. The results show that avalanche gain > 50 is achievable in the HARP layers developed in large area coaters, which is sufficient to achieve x-ray quantum noise limited performance down to a single x-ray photon per pixel. Both chromium (Cr) and indium tin oxide (ITO) have been successfully tested as pixel electrodes.

  7. Molecular structure of vapor-deposited amorphous selenium

    Science.gov (United States)

    Goldan, A. H.; Li, C.; Pennycook, S. J.; Schneider, J.; Blom, A.; Zhao, W.

    2016-10-01

    The structure of amorphous selenium is clouded with much uncertainty and contradictory results regarding the dominance of polymeric chains versus monomer rings. The analysis of the diffraction radial distribution functions are inconclusive because of the similarities between the crystalline allotropes of selenium in terms of the coordination number, bond length, bond angle, and dihedral angle. Here, we took a much different approach and probed the molecular symmetry of the thermodynamically unstable amorphous state via analysis of structural phase transformations. We verified the structure of the converted metastable and stable crystalline structures using scanning transmission electron microscopy. In addition, given that no experimental technique can tell us the exact three-dimensional atomic arrangements in glassy semiconductors, we performed molecular-dynamic simulations using a well-established empirical three-body interatomic potential. We developed a true vapor-deposited process for the deposition of selenium molecules onto a substrate using empirical molecular vapor compositions and densities. We prepared both vapor-deposited and melt-quenched samples and showed that the simulated radial distribution functions match very well to experiment. The combination of our experimental and molecular-dynamic analyses shows that the structures of vapor- and melt-quenched glassy/amorphous selenium are quite different, based primarily on rings and chains, respectively, reflecting the predominant structure of the parent phase in its thermodynamic equilibrium.

  8. [Present state and future of flat panel detector in Japan].

    Science.gov (United States)

    Higashida, Yoshiharu

    2002-01-01

    In our country, the introduction of flat panel detector is carried out in the diagnosis region since before several years. In flat panel detector with the high image characteristic, large expectation is being placed. In this paper, image characteristic of flat panel detector and effectiveness of clinical application were reviewed. It is anticipated that flat panel detector with the excellent image characteristic gives large effect in the radiological diagnosis.

  9. Phosphors for flat panel emissive displays

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, M.T.; Walko, R.J.; Phillips, M.L.F.

    1995-07-01

    An overview of emissive display technologies is presented. Display types briefly described include: cathode ray tubes (CRTs), field emission displays (FEDs), electroluminescent displays (ELDs), and plasma display panels (PDPs). The critical role of phosphors in further development of the latter three flat panel emissive display technologies is outlined. The need for stable, efficient red, green, and blue phosphors for RGB fall color displays is emphasized.

  10. High-performance low-noise 128-channel readout-integrated circuit for flat-panel x-ray detector systems

    Science.gov (United States)

    Beuville, Eric J.; Belding, Mark; Costello, Adrienne N.; Hansen, Randy; Petronio, Susan M.

    2004-05-01

    A silicon mixed-signal integrated circuit is needed to extract and process x-ray induced signals from a coated flat panel thin film transistor array (TFT) in order to generate a digital x-ray image. Indigo Systems Corporation has designed, fabricated, and tested such a readout integrated circuit (ROIC), the ISC9717. This off-the-shelf, high performance, low-noise, 128-channel device is fully programmable with a multistage pipelined architecture and a 9 to 14-bit programmable A/D converter per channel, making it suitable for numerous X-ray medical imaging applications. These include high-resolution radiography in single frame mode and fluoroscopy where high frame rates are required. The ISC9717 can be used with various flat panel arrays and solid-state detectors materials: Selenium (Se), Cesium Iodide (CsI), Silicon (Si), Amorphous Silicon, Gallium Arsenide (GaAs), and Cadmium Zinc Telluride (CdZnTe). The 80-micron pitch ROIC is designed to interface (wire bonding or flip-chip) along one or two sides of the x-ray panel, where ROICs are abutted vertically, each reading out charge from pixels multiplexed onto 128 horizontal read lines. The paper will present the design and test results of the ROIC, including the mechanical and electrical interface to a TFT array, system performance requirements, output multiplexing of the digital signals to an off-board processor, and characterization test results from fabricated arrays.

  11. Characterization of an amorphous silicon flat panel for controlling the positioning accuracy of sheet; Caracterizacion de un panel plano de silicio amorfo para control de la exactitud en el posicionamiento de laminas

    Energy Technology Data Exchange (ETDEWEB)

    Martinez, J.; Gonzalez, V.; Gimeno, J.; Dolores, V. de los; Pastor, V.; Crispin, V.; Guardino, C.

    2011-07-01

    It has established a method for measuring the position of the blades in a multi leaf collimator (MLC) used to measure dose portal imaging device (EPID) of amorphous silicon, and verified its accuracy using radiochromic films and measures water with diode Cuba, techniques perfectly well validated in our institution. This dose profiles are studied for each sheet and determine their position at the point which has 50% of the dose in the open field.

  12. Flat-panel volume CT: fundamental principles, technology, and applications.

    Science.gov (United States)

    Gupta, Rajiv; Cheung, Arnold C; Bartling, Soenke H; Lisauskas, Jennifer; Grasruck, Michael; Leidecker, Christianne; Schmidt, Bernhard; Flohr, Thomas; Brady, Thomas J

    2008-01-01

    Flat-panel volume computed tomography (CT) systems have an innovative design that allows coverage of a large volume per rotation, fluoroscopic and dynamic imaging, and high spatial resolution that permits visualization of complex human anatomy such as fine temporal bone structures and trabecular bone architecture. In simple terms, flat-panel volume CT scanners can be thought of as conventional multidetector CT scanners in which the detector rows have been replaced by an area detector. The flat-panel detector has wide z-axis coverage that enables imaging of entire organs in one axial acquisition. Its fluoroscopic and angiographic capabilities are useful for intraoperative and vascular applications. Furthermore, the high-volume coverage and continuous rotation of the detector may enable depiction of dynamic processes such as coronary blood flow and whole-brain perfusion. Other applications in which flat-panel volume CT may play a role include small-animal imaging, nondestructive testing in animal survival surgeries, and tissue-engineering experiments. Such versatility has led some to predict that flat-panel volume CT will gain importance in interventional and intraoperative applications, especially in specialties such as cardiac imaging, interventional neuroradiology, orthopedics, and otolaryngology. However, the contrast resolution of flat-panel volume CT is slightly inferior to that of multidetector CT, a higher radiation dose is needed to achieve a comparable signal-to-noise ratio, and a slower scintillator results in a longer scanning time.

  13. [Flat-panel detectors in X-ray systems].

    Science.gov (United States)

    Spahn, M; Heer, V; Freytag, R

    2003-05-01

    For all application segments X-ray systems with flat-panel detectors increasingly enter the market. In digital radiography,mammography and cardiologic angiography flat-panel detectors are already well established while they are made ready for market introduction in general angiography and fluoroscopy. Two flat-panel detector technologies are available. One technology is based on an indirect conversion process of X-rays while the other one uses a direct conversion method. For radiography and dynamic applications the indirect method provides substantial advantages, while the direct method has some benefits for mammography. In radiography and mammography flat-panel detectors lead to clear improvements with respect to workflow, image quality and dose reduction potentials. These improvements are fostered by the immediate availability of the image, the large dynamic range and the high sensitivity to X-rays. New applications and the use of complex image processing algorithms have the potential to enlarge the present diagnostic range of applications. Up to now, image intensifiers are still the well-established technology for angiography and fluoroscopy. Nevertheless flat-panel detectors begin to enter this field, especially in cardiologic angiography. Characteristics of flat-panel detectors such as the availability of distortion-free images, the excellent contrast resolution, the large dynamic range, the high sensitivity to X-rays and the usability in magnetic fields provide the basis for improved and new diagnostic and interventional methods.

  14. Second harmonic generation from an individual amorphous selenium nanosphere

    Science.gov (United States)

    Ma, C. R.; Yan, J. H.; Wei, Y. M.; Yang, G. W.

    2016-10-01

    Among the numerous nonlinear optics effects, second harmonic generation (SHG) is always a hotspot and it is extensively used for optical frequency conversion, biomedical imaging, etc. However, SHG is forbidden in a medium with inversion symmetry under the electric-dipole approximation. Here, we demonstrated SHG from a single amorphous selenium (a-Se) nanosphere under near-infrared femtosecond pulse excitation. It was found that SH spectra are tunable with the size of a-Se nanospheres and the SHG efficiency of a single a-Se sphere with a diameter over 300 nm is estimated at 10-8. We also established two physical mechanisms of SHG from the amorphous nanospheres. There is an electric-dipole contribution to the second-order nonlinearity in view of the inevitable structural discontinuity at the surface. The discontinuity of the normal component of the electric field strength leads to the quadrupole-type contributions arising from the large electric field gradient. The SHG process can be enhanced by resonance near the fundamental wavelength, giving rise to the detectable second harmonic (SH) spectra of a single a-Se nanosphere (d > 300 nm) or two small a-Se nanospheres (d = 200 nm) aggregated into a dimer, while the single nanosphere with smaller size (d > 300 nm) is undetectable. As an essential trace element for animals, a-Se features unique biological compatibility and has specific properties of optical nonlinearity within the optical window in biological tissue. This discovery makes a-Se nanospheres promising both in nonlinear optics and biomedicine.

  15. Flat-panel electronic displays: a triumph of physics, chemistry and engineering.

    Science.gov (United States)

    Hilsum, Cyril

    2010-03-13

    This paper describes the history and science behind the development of modern flat-panel displays, and assesses future trends. Electronic displays are an important feature of modern life. For many years the cathode ray tube, an engineering marvel, was universal, but its shape was cumbersome and its operating voltage too high. The need for a flat-panel display, working at a low voltage, became imperative, and much research has been applied to this need. Any versatile flat-panel display will exploit an electro-optical effect, a transparent conductor and an addressing system to deliver data locally. The first need is to convert an electrical signal into a visible change. Two methods are available, the first giving emission of light, the second modulating ambient illumination. The most useful light-emitting media are semiconductors, historically exploiting III-V or II-VI compounds, but more recently organic or polymer semiconductors. Another possible effect uses gas plasma discharges. The modulating, or subtractive, effects that have been studied include liquid crystals, electrophoresis, electrowetting and electrochromism. A transparent conductor makes it possible to apply a voltage to an extended area while observing the results. The design is a compromise, since the free electrons that carry current also absorb light. The first materials used were metals, but some semiconductors, when heavily doped, give a better balance, with high transmission for a low resistance. Delivering data unambiguously to a million or so picture elements across the display area is no easy task. The preferred solution is an amorphous silicon thin-film transistor deposited at each cross-point in an X-Y matrix. Success in these endeavours has led to many applications for flat-panel displays, including television, flexible displays, electronic paper, electronic books and advertising signs.

  16. Comparison of low-contrast detail perception on storage phosphor radiographs and digital flat panel detector images.

    Science.gov (United States)

    Peer, S; Neitzel, U; Giacomuzzi, S M; Peer, R; Gassner, E; Steingruber, I; Jaschke, W

    2001-03-01

    A contrast detail analysis was performed to compare perception of low-contrast details on X-ray images derived from digital storage phosphor radiography and from a flat panel detector system based on a cesium iodide/amorphous silicon matrix. The CDRAD 2.0 phantom was used to perform a comparative contrast detail analysis of a clinical storage phosphor radiography system and an indirect type digital flat panel detector unit. Images were acquired at exposure levels comparable to film speeds of 50/100/200/400 and 800. Four observers evaluated a total of 50 films with respect to the threshold contrast for each detail size. The numbers of correctly identified objects were determined for all image subsets. The overall results show that low-contrast detail perception with digital flat panel detector images is better than with state of the art storage phosphor screens. This is especially true for the low-exposure setting, where a nearly 10% higher correct observation ratio is reached. Given its high detective quantum efficiency the digital flat panel technology based on the cesium iodide scintillator/amorphous silicon matrix is best suited for detection of low-contrast detail structures, which shows its high potential for clinical imaging.

  17. Electroluminescent Polymers and Carbon Nanotubes for Flat Panel Displays

    Institute of Scientific and Technical Information of China (English)

    Liming Dai; Limin Dong; Mei Gao; Shaoming Huang; Oddvar Johansen; Albert W.H.Mau,Zoran Vasic; Berthold Winkler; Yongyuang Yang

    2000-01-01

    polymeric light-emitting diodes(LEDs) with sufficient brightness. efficiencies, low driving voltages, and various interesting features have been reported. The relatively short device lifetime, however, still remains as a major problem to be solved before any commercial applications will be realized. In this regard,carbon nanotubes have recently been proposed as more robust electron field emitters for flat panel displays. We have synthesised large arrays of vertically aligned carbon nanotubes, from which micropatterns of the aligned nanotubes suitable for flat panel displays were fabricated on various substrates. In this paper, we summarise our work on the synthesis and microfabrication of electroluminescent polymers and carbon nanotubes for flat panel displays with reference to other complementary work as appropriate.

  18. Technical advances of interventional fluoroscopy and flat panel image receptor.

    Science.gov (United States)

    Lin, Pei-Jan Paul

    2008-11-01

    In the past decade, various radiation reducing devices and control circuits have been implemented on fluoroscopic imaging equipment. Because of the potential for lengthy fluoroscopic procedures in interventional cardiovascular angiography, these devices and control circuits have been developed for the cardiac catheterization laboratories and interventional angiography suites. Additionally, fluoroscopic systems equipped with image intensifiers have benefited from technological advances in x-ray tube, x-ray generator, and spectral shaping filter technologies. The high heat capacity x-ray tube, the medium frequency inverter generator with high performance switching capability, and the patient dose reduction spectral shaping filter had already been implemented on the image intensified fluoroscopy systems. These three underlying technologies together with the automatic dose rate and image quality (ADRIQ) control logic allow patients undergoing cardiovascular angiography procedures to benefit from "lower patient dose" with "high image quality." While photoconductor (or phosphor plate) x-ray detectors and signal capture thin film transistor (TFT) and charge coupled device (CCD) arrays are analog in nature, the advent of the flat panel image receptor allowed for fluoroscopy procedures to become more streamlined. With the analog-to-digital converter built into the data lines, the flat panel image receptor appears to become a digital device. While the transition from image intensified fluoroscopy systems to flat panel image receptor fluoroscopy systems is part of the on-going "digitization of imaging," the value of a flat panel image receptor may have to be evaluated with respect to patient dose, image quality, and clinical application capabilities. The advantage of flat panel image receptors has yet to be fully explored. For instance, the flat panel image receptor has its disadvantages as compared to the image intensifiers; the cost of the equipment is probably the most

  19. Unfolding X-ray spectra using a flat panel detector.

    Science.gov (United States)

    Gallardo, Sergio; Juste, Belén; Pozuelo, Fausto; Ródenas, José; Querol, Andrea; Verdú, Gumersindo

    2013-01-01

    It is difficult to measure the energy spectrum of X-ray tubes due to the pile up effect produced by the high fluence of photons. Using attenuating materials, appropriate detector devices and the Monte Carlo method, primary X-ray spectrum of these devices can be estimated. In this work, a flat panel detector with a PMMA wedge has been used to obtain a dose curve corresponding to certain working conditions of a radiodiagnostic X-ray tube. The relation between the dose curve recorded by the flat panel and the primary X-ray spectrum is defined by a response function. Normally this function can be approximated by a matrix, which can be obtained by means of the Monte Carlo method. Knowing the measured dose curve and the response matrix, the primary X-ray spectrum can be unfolded. However, there are some problems that strongly affect the applicability of this method: i.e. technical features of the flat panel and inherent characteristics of the involved radiation physics (ill-posed problem). Both aspects are analyzed in this work, concluding that the proposed method can be applied with an acceptable accuracy for spectra without characteristic lines, for instance, tungsten anode in the 50-70 kVp range.

  20. Reconstruction of Spectra Using X-ray Flat Panel Detector; Reconstruccion de Espectros de Rayos X Utilizando un Detector Flat Panel

    Energy Technology Data Exchange (ETDEWEB)

    Gallardo, S.; Querol, A.; Pozuelo, F.; Juste, B.; Rodenas, J.; Verdu, G.

    2013-07-01

    In this work, we used a flat panel detector with a wedge of PMMA for absorbed dose curve for given working conditions of X-ray tube The relationship between absorbed dose curve recorded by the flat panel and primary X-ray spectrum is defined by a response function that can be obtained using the Monte Carlo method, namely the MCNP5 code. However there are some problems that affect the applicability of this method such as: flat panel characteristics and the characteristics of the physical process (ill-conditioned problem). Both aspects are discussed in this paper.

  1. Data pre-processing for quantification in tomography and radiography with a digital flat panel detector

    Science.gov (United States)

    Rinkel, Jean; Gerfault, Laurent; Estève, François; Dinten, Jean-Marc

    2006-03-01

    In order to obtain accurate quantitative results, flat panel detectors require specific calibration and correction of acquisitions. Main artefacts are due to bad pixels, variations of photodiodes characteristics and inhomogeneity of X-rays sensitivity of the scintillator layer. Other limitations for quantification are the non-linearity of the detector due to charge trapping in the transistors and the scattering generated inside the detector, called detector scattering. Based on physical models of artefacts generation, this paper presents an unified framework for the calibration and correction of these artefacts. The following specific algorithms have been developed to correct them. A new method for correction of deviation to linearity is based on the comparison between experimental and simulated data. A method of detector scattering correction is performed in two steps: off-line characterization of detector scattering by considering its spatial distribution through a convolution model and on-line correction based on a deconvolution approach. Radiographic results on an anthropomorphic thorax phantom imaged with a flat panel detector, that convert X-rays into visible light using scintillator coupled to an amorphous silicon transistor frame for photons to electrons conversion, demonstrate that experimental X-rays attenuation images are significantly improved qualitatively and quantitatively by applying non-linearity correction and detector scattering correction. Results obtained on tomographic reconstructions from pre-processed acquisitions of the phantom are in very good agreement with expected attenuation coefficients values obtained with a multi-slice CT scanner. Thus, this paper demonstrates the efficiency of the proposed pre-processings to perform accurate quantification on radiographies and tomographies.

  2. Rapid, room-temperature synthesis of amorphous selenium/protein composites using Capsicum annuum L extract

    Science.gov (United States)

    Li, Shikuo; Shen, Yuhua; Xie, Anjian; Yu, Xuerong; Zhang, Xiuzhen; Yang, Liangbao; Li, Chuanhao

    2007-10-01

    We describe the formation of amorphous selenium (α-Se)/protein composites using Capsicum annuum L extract to reduce selenium ions (SeO32-) at room temperature. The reaction occurs rapidly and the process is simple and easy to handle. A protein with a molecular weight of 30 kDa extracted from Capsicum annuum L not only reduces the SeO32- ions to Se0, but also controls the nucleation and growth of Se0, and even participates in the formation of α-Se/protein composites. The size and shell thickness of the α-Se/protein composites increases with high Capsicum annuum L extract concentration, and decreases with low reaction solution pH. The results suggest that this eco-friendly, biogenic synthesis strategy could be widely used for preparing inorganic/organic biocomposites. In addition, we also discuss the possible mechanism of the reduction of SeO32- ions by Capsicum annuum L extract.

  3. Carbon Nanotube Thin Film Transistors for Flat Panel Display Application.

    Science.gov (United States)

    Liang, Xuelei; Xia, Jiye; Dong, Guodong; Tian, Boyuan; Peng, Lianmao

    2016-12-01

    Carbon nanotubes (CNTs) are promising materials for both high performance transistors for high speed computing and thin film transistors for macroelectronics, which can provide more functions at low cost. Among macroelectronics applications, carbon nanotube thin film transistors (CNT-TFT) are expected to be used soon for backplanes in flat panel displays (FPDs) due to their superior performance. In this paper, we review the challenges of CNT-TFT technology for FPD applications. The device performance of state-of-the-art CNT-TFTs are compared with the requirements of TFTs for FPDs. Compatibility of the fabrication processes of CNT-TFTs and current TFT technologies are critically examined. Though CNT-TFT technology is not yet ready for backplane production line of FPDs, the challenges can be overcome by close collaboration between research institutes and FPD manufacturers in the short term.

  4. [Clinical study with angiography system using a flat panel detecter].

    Science.gov (United States)

    Ichida, Takao; Okusako, Kenji; Yokoyama, Kouji; Shougaki, Masachika; Ogawa, Takayoshi; Kawahata, Hideki; Nasu, Takehisa; Hosogai, Minoru; Okuyama, Kazuo; Hatagawa, Masakatsu

    2004-08-01

    We have been using an X-ray angiography system that incorporates a flat panel detector (FPD) since December 2001. This system is equipped with the scintillator-type FPD PaxScan 4030A from Varian Medical Systems, and for objective comparison of the image intensifier (I.I.) and FPD, the system is constructed so that these detectors can be used alternatively. Using this system and other X-ray angiography systems, visual studies have been conducted on the digital subtraction angiography (DSA) images acquired by FPD and I.I. We have found from the clinical images that the FPD is superior to the I.I. in depiction of fine blood vessels as well as of physical characteristics. Fluoroscopy images acquired by the FPD were not entirely satisfactory, however the improvement made in its performance now permits equal use of the FPD and I.I. systems.

  5. Optimized anti-scatter grids for flat panel detectors

    Science.gov (United States)

    Lendl, Markus

    2007-03-01

    Anti-scatter grids are well established in the field of X-ray projection imaging. In general these grids consist of a large number of parallel lead lamellae separated by X-ray-transparent material. This regular structure defines the characteristic grid frequency. Modern X-ray imaging systems apply digital receptors, i.e. image intensifiers coupled to a CCD camera or solid state flat-panel detector. Combining a digital detector and an anti-scatter grid may lead to Moire artifacts. This results from sampling an analog X-ray image with signal components higher than half the sampling frequency. Especially in high dose DSA images (Digital Subtraction Angiography) these irritating artifacts may be visible to the user. In this paper we present a concept for minimizing these grid artifacts: Signal propagation in the detector is modeled by three steps, scintillator MTF, aperture MTF, and sampling. Since the scintillator MTF is irrelevant for the grid optimization process, we focus on aperture MTF and sampling. From the given geometry of the detector elements the corresponding 2D Fourier transform is calculated. An evaluation for typical grid frequencies, i.e. arcs around the origin of the 2D Fourier transform, results in profiles exhibiting pronounced minima. From the respective angle values for these minima, grid orientation can be optimized for minimum Moire disturbances. Simulation results for typical detector pixel geometries and for grid frequencies used in practice are validated by measurement for two different anti-scatter grids on a Siemens angiographic system with a digital flat-panel detector.

  6. Cryogenic flat-panel gas-gap heat switch

    Science.gov (United States)

    Vanapalli, S.; Keijzer, R.; Buitelaar, P.; ter Brake, H. J. M.

    2016-09-01

    A compact additive manufactured flat-panel gas-gap heat switch operating at cryogenic temperature is reported in this paper. A guarded-hot-plate apparatus has been developed to measure the thermal conductance of the heat switch with the heat sink temperature in the range of 100-180 K. The apparatus is cooled by a two-stage GM cooler and the temperature is controlled with a heater and a braided copper wire connection. A thermal guard is mounted on the hot side of the device to confine the heat flow axially through the sample. A gas handling system allows testing the device with different gas pressures in the heat switch. Experiments are performed at various heat sink temperatures, by varying gas pressure in the gas-gap and with helium, hydrogen and nitrogen gas. The measured off-conductance with a heat sink temperature of 115 K and the hot plate at 120 K is 0.134 W/K, the on-conductance with helium and hydrogen gases at the same temperatures is 4.80 W/K and 4.71 W/K, respectively. This results in an on/off conductance ratio of 37 ± 7 and 35 ± 6 for helium and hydrogen respectively. The experimental results matches fairly well with the predicted heat conductance at cryogenic temperatures.

  7. Light sharing in multi-flat-panel-PMT PEM detectors.

    Science.gov (United States)

    Raylman, Raymond R; Majewski, Stan; Mayhugh, Michael R

    2006-01-01

    Large are a detectors, such as those used in positron emission mammography (PEM) and scintimammography, utilize arrays of discrete semtillator elements mounted on arrays of position sensitive photomultiplier tubes (PSPMT). Scintillator elements can be packed very densely (minimizing area between elements), allowing good detection sensitivity and spatial resolution. And, while new flat panel PSPMTS have minimal inactive edges, when they are placed in arrays significant dead spaces where scintillation light is undetectable are created. To address this problem, a light guide is often placed between the detector and PSPMT array to spread scintillation light so that these gaps can be bridged. In this investigation we studied the effect of light guides of various thickness on system performance. A 10x10 element array of LYSO detector elements was coupled to the center of a 2x2 array of PSPMTs through varying thicknesses (1 to 4 mm) of UV glass. The spot size of the imaged elements and distortions in the regular square pattern of the imaged scintillator arrays were evaluated. Energy resolution was measured by placing single elements of LYSO at several locations of the PSPMT array. Spatial distortions in the images of the array were reduced by using thicker light guides (3-4 mm). Use of thicker light guides, however, resulted in reduced pixel resolution and slight degradation of energy resolution. Therefore, some loss of pixel and energy resolution will accompany the use of thick light guides (minimum of 3 mm) required for optimum identification of detector elements.

  8. Investigation of hole-blocking contacts for high-conversion-gain amorphous selenium detectors for X-ray imaging

    NARCIS (Netherlands)

    Abbaszadeh, S.; Allec, N.; Ghanbarzadeh, S.; Shafique, U.; Karim, K.S.

    2012-01-01

    In this paper, we investigated different organic and inorganic hole-blocking contacts for amorphous selenium (a-Se)-based photodetectors: CeO2, TiO2, perylene tetracarboxylic bisbenzimidazole (PTCBI), and polyimide (PI). CeO2 has previously been used as a blocking layer for high-gain a-Se devices. T

  9. High-energy X-ray diffraction using the Pixium 4700 flat-panel detector.

    Science.gov (United States)

    Daniels, J E; Drakopoulos, M

    2009-07-01

    The Pixium 4700 detector represents a significant step forward in detector technology for high-energy X-ray diffraction. The detector design is based on digital flat-panel technology, combining an amorphous Si panel with a CsI scintillator. The detector has a useful pixel array of 1910 x 2480 pixels with a pixel size of 154 microm x 154 microm, and thus it covers an effective area of 294 mm x 379 mm. Designed for medical imaging, the detector has good efficiency at high X-ray energies. Furthermore, it is capable of acquiring sequences of images at 7.5 frames per second in full image mode, and up to 60 frames per second in binned region of interest modes. Here, the basic properties of this detector applied to high-energy X-ray diffraction are presented. Quantitative comparisons with a widespread high-energy detector, the MAR345 image plate scanner, are shown. Other properties of the Pixium 4700 detector, including a narrow point-spread function and distortion-free image, allows for the acquisition of high-quality diffraction data at high X-ray energies. In addition, high frame rates and shutterless operation open new experimental possibilities. Also provided are the necessary data for the correction of images collected using the Pixium 4700 for diffraction purposes.

  10. An asynchronous, pipelined, electronic acquisition system for Active Matrix Flat-Panel Imagers (AMFPIs)

    Energy Technology Data Exchange (ETDEWEB)

    Huang, W.; Antonuk, L.E. E-mail: antonuk@umich.edu; Berry, J.; Maolinbay, M.; Martelli, C.; Mody, P.; Nassif, S.; Yeakey, M

    1999-07-11

    The development of a full-custom electronic acquisition system designed for readout of large-area active matrix flat-panel imaging arrays is reported. The arrays, which comprise two-dimensional matrices of pixels utilizing amorphous silicon thin-film transistors, are themselves under development for a wide variety of X-ray imaging applications. The acquisition system was specifically designed to facilitate detailed, quantitative investigations of the properties of these novel imaging arrays and contains significant enhancements compared to a previously developed acquisition system. These enhancements include pipelined preamplifier circuits to allow faster readout speed, expanded addressing capabilities allowing a maximum of 4096 array data lines, and on-board summing of image frames. The values of many acquisition system parameters, including timings and voltages, may be specified and downloaded from a host computer. Once acquisition is enabled, the system operates asynchronously of its host computer. The system allows image capture in both radiographic mode (corresponding to the capture of individual X-ray images), and fluoroscopic mode (corresponding to the capture of a continual series of X-ray images). A detailed description of the system architecture and the underlying motivations for the design is reported in this paper. (author)

  11. Solid-state, flat-panel, digital radiography detectors and their physical imaging characteristics.

    Science.gov (United States)

    Cowen, A R; Kengyelics, S M; Davies, A G

    2008-05-01

    Solid-state, digital radiography (DR) detectors, designed specifically for standard projection radiography, emerged just before the turn of the millennium. This new generation of digital image detector comprises a thin layer of x-ray absorptive material combined with an electronic active matrix array fabricated in a thin film of hydrogenated amorphous silicon (a-Si:H). DR detectors can offer both efficient (low-dose) x-ray image acquisition plus on-line readout of the latent image as electronic data. To date, solid-state, flat-panel, DR detectors have come in two principal designs, the indirect-conversion (x-ray scintillator-based) and the direct-conversion (x-ray photoconductor-based) types. This review describes the underlying principles and enabling technologies exploited by these designs of detector, and evaluates their physical imaging characteristics, comparing performance both against each other and computed radiography (CR). In standard projection radiography indirect conversion DR detectors currently offer superior physical image quality and dose efficiency compared with direct conversion DR and modern point-scan CR. These conclusions have been confirmed in the findings of clinical evaluations of DR detectors. Future trends in solid-state DR detector technologies are also briefly considered. Salient innovations include WiFi-enabled, portable DR detectors, improvements in x-ray absorber layers and developments in alternative electronic media to a-Si:H.

  12. Resolution requirements for monitor viewing of digital flat-panel detector radiographs: a contrast detail analysis

    Science.gov (United States)

    Peer, Siegfried; Steingruber, Iris; Gassner, Eva; Peer, Regina; Giacomuzzi, Salvatore M.

    2002-05-01

    Since the introduction of digital flat panel detectors into clinical routine the discussion on monitor specifications for primary soft copy reading has gained new impetus. Major concerns exist for viewing of tiny opacities such as pulmonary nodules. In this study CDRAD phantom images were acquired on a caesium iodid/amorphous silicon detector at varying exposure levels. Images were read three times by three observers on a clinical 1K and 2K monitor workstation. All typical workstation functions such as magnification and window/level setting were applied during image reading. Correct detection ratios were calculated according to the CDRAD evaluation manual. Observer ratings were highest for high dose exposure and 2K monitor reading. No significant difference was detected in the correct detection ratio of observers. However, the difference between the two types of workstations (1K versus 2K monitors) despite less than 3% was significant at a 95% confidence level. This is in good accordance with recently published clinical studies. However, further clinical work will be needed to strengthen this laboratory based impression. Given these subtle differences in low contrast detail detection on 1K and 2K clinical PACS workstation we should probably rethink the recommendations of various national boards for the use of 2K monitors.

  13. Focal spot measurements using a digital flat panel detector

    Science.gov (United States)

    Jain, Amit; Panse, A.; Bednarek, Daniel R.; Rudin, Stephen

    2014-03-01

    Focal spot size is one of the crucial factors that affect the image quality of any x-ray imaging system. It is, therefore, important to measure the focal spot size accurately. In the past, pinhole and slit measurements of x-ray focal spots were obtained using direct exposure film. At present, digital detectors are replacing film in medical imaging so that, although focal spot measurements can be made quickly with such detectors, one must be careful to account for the generally poorer spatial resolution of the detector and the limited usable magnification. For this study, the focal spots of a diagnostic x-ray tube were measured with a 10-μm pinhole using a 194-μm pixel flat panel detector (FPD). The twodimensional MTF, measured with the Noise Response (NR) Method was used for the correction for the detector blurring. The resulting focal spot sizes based on the FWTM (Full Width at Tenth Maxima) were compared with those obtained with a very high resolution detector with 8-μm pixels. This study demonstrates the possible effect of detector blurring on the focal spot size measurements with digital detectors with poor resolution and the improvement obtained by deconvolution. Additionally, using the NR method for measuring the two-dimensional MTF, any non-isotropies in detector resolution can be accurately corrected for, enabling routine measurement of non-isotropic x-ray focal spots. This work presents a simple, accurate and quick quality assurance procedure for measurements of both digital detector properties and x-ray focal spot size and distribution in modern x-ray imaging systems.

  14. Rapid, room-temperature synthesis of amorphous selenium/protein composites using Capsicum annuum L extract

    Energy Technology Data Exchange (ETDEWEB)

    Li Shikuo; Shen Yuhua; Xie Anjian; Yu Xuerong; Zhang Xiuzhen; Yang Liangbao; Li Chuanhao [School of Chemistry and Chemical Engineering, Anhui University, Hefei 230039 (China)

    2007-10-10

    We describe the formation of amorphous selenium ({alpha}-Se)/protein composites using Capsicum annuum L extract to reduce selenium ions (SeO{sub 3}{sup 2-}) at room temperature. The reaction occurs rapidly and the process is simple and easy to handle. A protein with a molecular weight of 30 kDa extracted from Capsicum annuum L not only reduces the SeO{sub 3}{sup 2-} ions to Se{sup 0}, but also controls the nucleation and growth of Se{sup 0}, and even participates in the formation of {alpha}-Se/protein composites. The size and shell thickness of the {alpha}-Se/protein composites increases with high Capsicum annuum L extract concentration, and decreases with low reaction solution pH. The results suggest that this eco-friendly, biogenic synthesis strategy could be widely used for preparing inorganic/organic biocomposites. In addition, we also discuss the possible mechanism of the reduction of SeO{sub 3}{sup 2-} ions by Capsicum annuum L extract.

  15. Physical and optical properties of binary amorphous selenium-antimony thin films

    Science.gov (United States)

    Sharma, Pankaj; Sharma, Ishu; Katyal, S. C.

    2009-03-01

    Amorphous thin films with compositions Se1-xSbx (x =0, 0.025, 0.05, 0.075, and 0.10 at. %) have been deposited by thermal evaporation (at ˜10-4 Pa) from bulk samples. The compositional dependence of their optical properties, refractive index, extinction coefficient, absorption coefficient, and optical band gap with increasing Sb content is investigated using transmission spectra in the range of 400-1200 nm. The refractive-index dispersion has been analyzed on the basis of the Wemple-DiDomenico single-oscillator approach. It has been found that the refractive index increases with increasing Sb content. The behavior of the optical band gap, when the composition of the material is varied, shows, as expected, just the opposite trends. The optical band gap decreases from 2.025 to 1.753 eV with ±0.001 eV uncertainty. Band gap calculated theoretically also shows a decrease with the increase in Sb content. The optical behavior is supported by physical properties, i.e., decrease in optical band gap is supported by the decrease in cohesive energy of the system. Some other physical properties, viz., coordination number, lone-pair electrons, and glass transition temperature, are also investigated theoretically. The optical results may lead to yield more sensitive detectors based on amorphous selenium, and physical properties may be useful in achieving more stable alloys which are favorable in x-ray imaging applications.

  16. Human health and ecological toxicity potentials due to heavy metal content in waste electronic devices with flat panel displays

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Seong-Rin [Department of Chemical Engineering and Materials Science, University of California, 2017 Kemper Hall, One Shields Avenue, Davis, CA 95616 (United States); Schoenung, Julie M., E-mail: jmschoenung@ucdavis.edu [Department of Chemical Engineering and Materials Science, University of California, 2017 Kemper Hall, One Shields Avenue, Davis, CA 95616 (United States)

    2010-05-15

    Display devices such as cathode-ray tube (CRT) televisions and computer monitors are known to contain toxic substances and have consequently been banned from disposal in landfills in the State of California and elsewhere. New types of flat panel display (FPD) devices, millions of which are now purchased each year, also contain toxic substances, but have not previously been systematically studied and compared to assess the potential impact that could result from their ultimate disposal. In the current work, the focus is on the evaluation of end-of-life toxicity potential from the heavy metal content in select FPD devices with the intent to inform material selection and design-for-environment (DfE) decisions. Specifically, the metals antimony, arsenic, barium, beryllium, cadmium, chromium, cobalt, copper, lead, mercury, molybdenum, nickel, selenium, silver, vanadium, and zinc in plasma TVs, LCD (liquid crystal display) TVs, LCD computer monitors and laptop computers are considered. The human health and ecotoxicity potentials are evaluated through a life cycle assessment perspective by combining data on the respective heavy metal contents, the characterization factors in the U.S. EPA Tool for the Reduction and Assessment of Chemical and other environmental Impacts (TRACI), and a pathway and impact model. Principal contributors to the toxicity potentials are lead, arsenic, copper, and mercury. Although the heavy metal content in newer flat panel display devices creates less human health toxicity potential than that in CRTs, for ecological toxicity, the new devices are worse, especially because of the mercury in LCD TVs and the copper in plasma TVs.

  17. Human health and ecological toxicity potentials due to heavy metal content in waste electronic devices with flat panel displays.

    Science.gov (United States)

    Lim, Seong-Rin; Schoenung, Julie M

    2010-05-15

    Display devices such as cathode-ray tube (CRT) televisions and computer monitors are known to contain toxic substances and have consequently been banned from disposal in landfills in the State of California and elsewhere. New types of flat panel display (FPD) devices, millions of which are now purchased each year, also contain toxic substances, but have not previously been systematically studied and compared to assess the potential impact that could result from their ultimate disposal. In the current work, the focus is on the evaluation of end-of-life toxicity potential from the heavy metal content in select FPD devices with the intent to inform material selection and design-for-environment (DfE) decisions. Specifically, the metals antimony, arsenic, barium, beryllium, cadmium, chromium, cobalt, copper, lead, mercury, molybdenum, nickel, selenium, silver, vanadium, and zinc in plasma TVs, LCD (liquid crystal display) TVs, LCD computer monitors and laptop computers are considered. The human health and ecotoxicity potentials are evaluated through a life cycle assessment perspective by combining data on the respective heavy metal contents, the characterization factors in the U.S. EPA Tool for the Reduction and Assessment of Chemical and other environmental Impacts (TRACI), and a pathway and impact model. Principal contributors to the toxicity potentials are lead, arsenic, copper, and mercury. Although the heavy metal content in newer flat panel display devices creates less human health toxicity potential than that in CRTs, for ecological toxicity, the new devices are worse, especially because of the mercury in LCD TVs and the copper in plasma TVs.

  18. Use and imaging performance of CMOS flat panel imager with LiF/ZnS(Ag) and Gadox scintillation screens for neutron radiography

    Science.gov (United States)

    Cha, B. K.; kim, J. Y.; Kim, T. J.; Sim, C.; Cho, G.; Lee, D. H.; Seo, C.-W.; Jeon, S.; Huh, Y.

    2011-01-01

    In digital neutron radiography system, a thermal neutron imaging detector based on neutron-sensitive scintillating screens with CMOS(complementary metal oxide semiconductor) flat panel imager is introduced for non-destructive testing (NDT) application. Recently, large area CMOS APS (active-pixel sensor) in conjunction with scintillation films has been widely used in many digital X-ray imaging applications. Instead of typical imaging detectors such as image plates, cooled-CCD cameras and amorphous silicon flat panel detectors in combination with scintillation screens, we tried to apply a scintillator-based CMOS APS to neutron imaging detection systems for high resolution neutron radiography. In this work, two major Gd2O2S:Tb and 6LiF/ZnS:Ag scintillation screens with various thickness were fabricated by a screen printing method. These neutron converter screens consist of a dispersion of Gd2O2S:Tb and 6LiF/ZnS:Ag scintillating particles in acrylic binder. These scintillating screens coupled-CMOS flat panel imager with 25x50mm2 active area and 48μm pixel pitch was used for neutron radiography. Thermal neutron flux with 6x106n/cm2/s was utilized at the NRF facility of HANARO in KAERI. The neutron imaging characterization of the used detector was investigated in terms of relative light output, linearity and spatial resolution in detail. The experimental results of scintillating screen-based CMOS flat panel detectors demonstrate possibility of high sensitive and high spatial resolution imaging in neutron radiography system.

  19. Do LCDs have a chance to keep a leading position on flat panel display market?

    Science.gov (United States)

    Zielinski, Jerzy; Olifierczuk, Marek

    2004-09-01

    A lot of significant discoveries and inventions in the field of technology of displays were made in the latter part of the twentieth century. Apart from well-known CRT, the plasma-, luminescence- and liquid crystal-displays are commercially available. One can notice that a leading position on that flat panel displays market belong to LCD. But the progress in Organic LED materials and devices is impressive. Threshold voltage for light emission have fallen from several thousands V to just 2 - 3 V for today's OLEDs (polymer and small molecule). Luminous efficiency has increased from 0,01 to more than 10 lm/W. These improvements have brought PLED technology to the point where serious consideration is being given to OLED graphic and video display product. The question given some years ago by Dr. M. E. Becker, [Display Metrology and Systems]: "...is the current OLED enthusiasm justified because OLED displays feature significant improvements in visual and ergonomic performance, and because they are much cheaper to manufacture; Or it is just another hope for those who missed the LCD train?...," is trite. During SID Conference in Baltimore in 2003 two companies claiming to have built the largest organic LED. International Display Technology demonstrated a 20 inch display driven by "super amorphous silicon" technology; Sony showed off its 24 inch screen, which consists of a 2x2 tiled array of OLED displays. The presented work will be oriented towards specifying the characteristic features of liquid crystal and electro luminescence organic compounds which make these groups of displays so attractive and prospective among other imagery systems devices existing nowadays.

  20. Comparison measurements of DQE for two flat panel detectors: fluoroscopic detector vs. cone beam CT detector

    Science.gov (United States)

    Betancourt Benítez, Ricardo; Ning, Ruola; Conover, David

    2006-03-01

    The physical performance of two flat panel detectors (FPD) has been evaluated using a standard x-ray beam quality set by IEC, namely RQA5. The FPDs evaluated in this study are based on an amorphous silicon photodiode array that is coupled to a thallium-doped Cesium Iodide scintillator and to a thin film transistor (TFT) array. One detector is the PaxScan 2520 that is designed for fluoro imaging, and has a small dynamic range and a large image lag. The other detector is the PaxScan 4030CB that is designed for cone beam CT, and has a large dynamic range (>16-bit), a reduced image lag and many imaging modes. Varian Medical Systems manufactured both detectors. The linearity of the FPDs was investigated by using an ionization chamber and aluminum filtration in order to obtain the beam quality. Since the FPDs are used in fluoroscopic mode, image lag of the FPD was measured in order to investigate its effect on this study, especially its effect on DQE. The spatial resolution of the FPDs was determined by obtaining the pre-sampling modulation transfer function for each detector. A sharp edge was used in accordance to IEC 62220-1. Next, the Normalized Noise Power Spectrum (NNPS) was calculated for various exposures levels at RQA5 radiation quality. Finally, the DQE of each FPD was obtained with a modified version of the international standard set by IEC 62220-1. The results show that the physical performance in DQE and MTF of the PaxScan 4030CB is superior to that of PaxScan2520.

  1. Modeling of photocurrent and lag signals in amorphous selenium x-ray detectors

    Energy Technology Data Exchange (ETDEWEB)

    Siddiquee, Sinchita; Kabir, M. Z., E-mail: kabir@encs.concordia.ca [Department of Electrical and Computer Engineering, Concordia University, 1455 Blvd. de Maisonneuve West, Montreal, Quebec H3G 1M8 (Canada)

    2015-07-15

    A mathematical model for transient photocurrent and lag signal in x-ray imaging detectors has been developed by considering charge carrier trapping and detrapping in the energy distributed defect states under exponentially distributed carrier generation across the photoconductor. The model for the transient and steady-state carrier distributions and hence the photocurrent has been developed by solving the carrier continuity equation for both holes and electrons. The residual (commonly known as lag signal) current is modeled by solving the trapping rate equations considering the thermal release and trap filling effects. The model is applied to amorphous selenium (a-Se) detectors for both chest radiography and mammography. The authors analyze the dependence of the residual current on various factors, such as x-ray exposure, applied electric field, and temperature. The electron trapping and detrapping mostly determines the residual current in a-Se detectors. The lag signal is more prominent in chest radiographic detector than in mammographic detectors. The model calculations are compared with the published experimental data and show a very good agreement.

  2. SWAD: inherent photon counting performance of amorphous selenium multi-well avalanche detector

    Science.gov (United States)

    Stavro, Jann; Goldan, Amir H.; Zhao, Wei

    2016-03-01

    Photon counting detectors (PCDs) have the potential to improve x-ray imaging, however they are still hindered by several performance limitations and high production cost. By using amorphous Selenium (a-Se) the cost of PCDs can be significantly reduced compared to crystalline materials and enable large area detector fabrication. To overcome the problem of low carrier mobility and low charge conversion gain in a-Se, we are developing a novel direct conversion a- Se field-Shaping multi-Well Avalanche Detector (SWAD). SWAD circumvents the charge transport limitation by using a Frisch grid built within the readout circuit, reducing charge collection time to ~200 ns. Field shaping permits depth independent avalanche gain in wells, resulting in total conversion gain that is comparable to Si and CdTe. In the present work we investigate the effects of charge sharing and energy loss to understand the inherent photon counting performance for SWAD at x-ray energies used in breast imaging applications (20-50keV). The energy deposition profile for each interacting x-ray was determined with Monte Carlo simulation. For the energy ranges we are interested in, photoelectric interaction dominates, with a k-fluorescence yield of approximately 60%. Using a monoenergetic 45 keV beam incident on a target pixel in 400um of a-Se, our results show that only 20.42 % and 22.4 % of primary interacting photons have kfluorescence emissions which escape the target pixel for 100um and 85um pixel sizes respectively, demonstrating SWAD's potential for high spatial resolution applications.

  3. Volumetry of human molars with flat panel-based volume CT in vitro

    NARCIS (Netherlands)

    Hannig, C.; Krieger, E.; Dullin, C.; Merten, H.A.; Attin, T.; Grabbe, E.; Heidrich, G.

    2006-01-01

    The flat panel-based volume computed tomography (fpVCT) is a new CT device applicable for experimental, three-dimensional evaluation of teeth at a resolution of about 150 microm in the high contrast region. The aim of this study was to investigate whether fpVCT was suitable for quantification of the

  4. [Flat-panel detector technology -State-of-the-art and future prospects-].

    Science.gov (United States)

    Yamazaki, Tatsuya

    2002-01-01

    A flat-panel detector (FPD) is a long-awaited technology to implement the digital X-ray imaging technology into the radiological department. This paper describes the state-of-the-art technology and future prospects on the FPD technology. State-of-the-art technology was reviewed taking the CXDI series as an example. Several FPD-based systems have been introduced into the Japanese market since CXDI-11 opened it in November 1998. Accompanying CXDI-C2 for control, CXDI-22 for table position and CXDI-31 for portable, the CXDI series fulfills the requirement of the radiography room being a fully digitalized room. The FPD on the CXDI series is comprised of a scintillator (Gd(2)O(2)S:Tb(3+)) as a primary sensor in which the X-ray is captured and an amorphous silicon detector (LANMIT) as a secondary sensor in which the fluorescent light is detected. Since the scintillator is identical to that of the screen-film systems, it can be said as proven, durable and chemically stable and it is expected to produce the same image quality as the screen-film systems. CXDI-31, a portable FPD-based system, was developed targeting thinner dimensions, lightweight, durability and high spatial resolution. Thoroughly re-designing the mechanical structure and reducing the power consumption at the readout IC realized thinner dimensions. Introducing the portable note PC technologies successfully combined lightweight with durability. Improving the sensor process and re-designing the layout made the sensor high resolution without compromising the signal-to-noise ratio. Future prospects were overviewed in the aspect of technology and applications. Sensitivity, spatial resolution, frame rate and portability were described as the upcoming technology. Increasing gain and reducing noise will realize higher sensitivity, especially by adopting the PbI(2), HgI(2) or such photoconductor materials as the primary sensor. Pixelized amplifier will also achieve higher sensitivity. Layered sensor designed such

  5. Blurring artifacts in megavoltage radiography with a flat-panel imaging system: comparison of Monte Carlo simulations with measurements.

    Science.gov (United States)

    Schach von Wittenau, A E; Logan, C M; Aufderheide, M B; Slone, D M

    2002-11-01

    Originally designed for use at medical-imaging x-ray energies, imaging systems comprising scintillating screens and amorphous Si detectors are also used at the megavoltage photon energies typical of portal imaging and industrial radiography. While image blur at medical-imaging x-ray energies is strongly influenced both by K-shell fluorescence and by the transport of optical photons within the scintillator layer, at higher photon energies the image blur is dominated by radiation scattered from the detector housing and internal support structures. We use Monte Carlo methods to study the blurring in a notional detector: a series of semi-infinite layers with material compositions, thicknesses, and densities similar to those of a commercially available flat-panel amorphous Si detector system comprising a protective housing, a gadolinium oxysulfide scintillator screen, and associated electronics. We find that the image blurring, as described by a point-spread function (PSF), has three length scales. The first component, with a submillimeter length scale, arises from electron scatter within the scintillator and detection electronics. The second component, with a millimeter-to-centimeter length scale, arises from electrons produced in the front cover of the detector. The third component, with a length scale of tens of centimeters, arises from photon scatter by the back cover of the detector. The relative contributions of each of these components to the overall PSF vary with incident photon energy. We present an algorithm that includes the energy-dependent sensitivity and energy-dependent PSF within a ray-tracing formalism. We find quantitative agreement (approximately 2%) between predicted radiographs with radiographs of copper step wedges, taken with a 9 MV bremsstrahlung source and a commercially available flat-panel system. The measured radiographs show the blurring artifacts expected from both the millimeter-scale electron transport and from the tens

  6. Establishment of action levels for quality control of IMRT flat panel: experience with the algorithm iGRiMLO; Establecimiento de niveles de accion para el control de calidad de IMRT con panel plano: experiencia con el algoritmo iGRiMLO

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, V.; Dolores, VV. de los; Pastor, V.; Martinez, J.; Gimeno, J.; Guardino, C.; Crispin, V.

    2011-07-01

    Algorithm has been used at our institution iGRiMLO scheduled for individual verification of treatment plans for intensity modulated radiotherapy (IMRT) step and shoot through portal dosimetry pretreatment of non-transmission, triggering the plan directly to a portal imaging device (EPID) of an amorphous silicon flat panel.

  7. Full dynamic resolution low lower DA-Converters for flat panel displays

    Directory of Open Access Journals (Sweden)

    C. Saas

    2006-01-01

    Full Text Available It has been shown that stepwise charging can reduce the power dissipated in the source drivers of a flat panel display. However the solution presented only provided a dynamic resolution of 3 bits which is not sufficient for obtaining a full color resolution display. In this work a further development of the basic idea is presented. The stepwise charging is increased to 4 bits and supplemented by a current source to provide an output signal which represents an 8 bit value with sufficient accuracy. Within this work the application is an AM-OLED flat panel display, but the concept can easily be applied to other display technologies like TFT-LCD as well.

  8. A novel heuristic for optimization aggregate production problem: Evidence from flat panel display in Malaysia

    Science.gov (United States)

    Al-Kuhali, K.; Hussain M., I.; Zain Z., M.; Mullenix, P.

    2015-05-01

    Aim: This paper contribute to the flat panel display industry it terms of aggregate production planning. Methodology: For the minimization cost of total production of LCD manufacturing, a linear programming was applied. The decision variables are general production costs, additional cost incurred for overtime production, additional cost incurred for subcontracting, inventory carrying cost, backorder costs and adjustments for changes incurred within labour levels. Model has been developed considering a manufacturer having several product types, which the maximum types are N, along a total time period of T. Results: Industrial case study based on Malaysia is presented to test and to validate the developed linear programming model for aggregate production planning. Conclusion: The model development is fit under stable environment conditions. Overall it can be recommended to adapt the proven linear programming model to production planning of Malaysian flat panel display industry.

  9. Development of CT and 3D-CT Using Flat Panel Detector Based Real-Time Digital Radiography System

    Science.gov (United States)

    Ravindran, V. R.; Sreelakshmi, C.; Vibin, Vibin

    2008-09-01

    The application of Digital Radiography in the Nondestructive Evaluation (NDE) of space vehicle components is a recent development in India. A Real-time DR system based on amorphous silicon Flat Panel Detector has been developed for the NDE of solid rocket motors at Rocket Propellant Plant of VSSC in a few years back. The technique has been successfully established for the nondestructive evaluation of solid rocket motors. The DR images recorded for a few solid rocket specimens are presented in the paper. The Real-time DR system is capable of generating sufficient digital X-ray image data with object rotation for the CT image reconstruction. In this paper the indigenous development of CT imaging based on the Realtime DR system for solid rocket motor is presented. Studies are also carried out to generate 3D-CT image from a set of adjacent CT images of the rocket motor. The capability of revealing the spatial location and characterisation of defect is demonstrated by the CT and 3D-CT images generated.

  10. Attenuated phase-shift mask (PSM) blanks for flat panel display

    Science.gov (United States)

    Kageyama, Kagehiro; Mochizuki, Satoru; Yamakawa, Hiroyuki; Uchida, Shigeru

    2015-10-01

    The fine pattern exposure techniques are required for Flat Panel display applications as smart phone, tablet PC recently. The attenuated phase shift masks (PSM) are being used for ArF and KrF photomask lithography technique for high end pattern Semiconductor applications. We developed CrOx based large size PSM blanks that has good uniformity on optical characteristics for FPD applications. We report the basic optical characteristics and uniformity, stability data of large sized CrOx PSM blanks.

  11. Competing Technologies and Industry Evolution: The Benefits of Making Mistakes in the Flat Panel Display Industry

    OpenAIRE

    Eggers, J.P.

    2010-01-01

    Managers at firms facing uncertain competing technologies evolving concurrently face a complex decision set, including options to invest in one technology or other, both technologies, or to wait to invest. This study investigates the role that experience, learning and timing play in affecting the firm-level pros and cons of each of these four strategies in a technological competition situation. Using a unique data set on the evolution of the global flat panel display industry, this study offe...

  12. Study of DQE dependence with beam quality on GE essential mammography flat panel.

    Science.gov (United States)

    García-Mollá, Rafael; Linares, Rafael; Ayala, Rafael

    2010-11-25

    This paper deals with the analysis of the behavior of objective image quality parameters for the new GE Senographe Essential FFDM system, in particular its dependence with beam quality. The detector consists of an indirect conversion a-Si flat panel coupled to a CsI:Tl scintillator. The system under study has gone through a series of relevant modifications in flat panel with respect to the previous model (GE Senographe DS 2000). These changes in the detector modify its performance and are intended to favor advanced applications like tomosynthesis, which uses harder beam spectra and lower doses per exposure than conventional FFDM. Although our system does not have tomosynthesis implemented, we noticed that most clinical explorations were performed by automatically selecting a harder spectrum than that of typical use in FFDM (Rh/Rh 28-30 kV instead of Mo/Mo 28 kV). Since flat-panel optimization for tomosynthesis influences the usual FFDM clinical performance, the new detector behavior needed to be investigated. Therefore, the aim of our study is evaluating the dependence of the detector performance for different beam spectra and exposure levels. In this way, we covered the clinical beam quality range (Rh/Rh 28-30 kV) and we extended the study to even harder spectra (Rh/Rh 34 kV). Detector performance is quantified by means of modulation transfer function (MTF), normalized noise power spectrum (NNPS) and detective quantum efficiency (DQE). We found that flat-panel optimization results in slightly - but statistically significant - higher DQE values as beam quality increases, which is contrary to the expected behavior. This positive correlation between beam quality and DQE is also diametrically opposite to that of the previous model by the same manufacturer. As a direct consequence, usual FFDM takes advantage of the changes in the detector, as less exposure is needed to achieve the same DQE if harder beams are used.

  13. Comparison of ring artifact removal methods using flat panel detector based CT images

    OpenAIRE

    2011-01-01

    Abstract Background Ring artifacts are the concentric rings superimposed on the tomographic images often caused by the defective and insufficient calibrated detector elements as well as by the damaged scintillator crystals of the flat panel detector. It may be also generated by objects attenuating X-rays very differently in different projection direction. Ring artifact reduction techniques so far reported in the literature can be broadly classified into two groups. One category of the approac...

  14. Qualification test results for DOE solar photovoltaic flat panel procurement - PRDA 38

    Science.gov (United States)

    Griffith, J. S.

    1980-01-01

    Twelve types of prototypes modules for the DOE Photovoltaic Flat Panel Procurement (PRDA 38) were subjected to qualification tests at the Jet Propulsion Laboratory according to a new specification. Environmental exposures were carried out separately and included temperature cycling, humidity, wind simulation, and hail. The most serious problems discovered were reduced insulation resistance to ground and ground continuity of the metal frames, electrical degradation, erratic power readings, and delamination. The electrical and physical characteristics of the newly received modules are also given.

  15. Preliminary performance of image quality for a low-dose C-arm CT system with a flat-panel detector

    Science.gov (United States)

    Kyung Cha, Bo; Seo, Chang-Woo; Yang, Keedong; Jeon, Seongchae; Huh, Young

    2015-06-01

    Digital flat panel imager (FPI)-based cone-beam computed tomography (CBCT) has been widely used in C-arm imaging for spine surgery and interventional procedures. The system provides real-time fluoroscopy with high spatial resolution and three-dimensional (3D) visualization of anatomical structure without the need for patient transportation in interventional suite. In this work, a prototype CBCT imaging platform with continuous single rotation about the gantry was developed by using a large-area flat-panel detector with amorphous Si-based thin film transistor matrix. The different 2D projection images were acquired during constant gantry velocity for reconstructed images at a tube voltage of 80-120 kVp, and different current (10-50 mA) conditions. Various scan protocols were applied to a chest phantom human by changing the number of projection images and scanning angles. The projections were then reconstructed into a volumetric data of sections by using a 3D reconstruction algorithm (e.g., filtered back projection). The preliminary quantitative X-ray performance of our CBCT system was investigated by using the American Association of Physicists in Medicine CT phantom in terms of spatial resolution, contrast resolution, and CT number linearity for mobile or fixed C-arm based CBCT application with limited rotational geometry. The novel results of the projection data with different scanning angles and angular increments in the orbital gantry platform were acquired and evaluated experimentally.

  16. Preliminary performance of image quality for a low-dose C-arm CT system with a flat-panel detector

    Energy Technology Data Exchange (ETDEWEB)

    Kyung Cha, Bo [Advanced Medical Device Research Center, Korea Electrotechnology Research Institute, Ansan (Korea, Republic of); Seo, Chang-Woo [Department of Radiation Convergence Engineering, College of Health Science, Yonsei University, Wonju (Korea, Republic of); Yang, Keedong [Advanced Medical Device Research Center, Korea Electrotechnology Research Institute, Ansan (Korea, Republic of); Jeon, Seongchae, E-mail: sarim@keri.re.kr [Advanced Medical Device Research Center, Korea Electrotechnology Research Institute, Ansan (Korea, Republic of); Huh, Young [Advanced Medical Device Research Center, Korea Electrotechnology Research Institute, Ansan (Korea, Republic of)

    2015-06-01

    Digital flat panel imager (FPI)-based cone-beam computed tomography (CBCT) has been widely used in C-arm imaging for spine surgery and interventional procedures. The system provides real-time fluoroscopy with high spatial resolution and three-dimensional (3D) visualization of anatomical structure without the need for patient transportation in interventional suite. In this work, a prototype CBCT imaging platform with continuous single rotation about the gantry was developed by using a large-area flat-panel detector with amorphous Si-based thin film transistor matrix. The different 2D projection images were acquired during constant gantry velocity for reconstructed images at a tube voltage of 80–120 kVp, and different current (10–50 mA) conditions. Various scan protocols were applied to a chest phantom human by changing the number of projection images and scanning angles. The projections were then reconstructed into a volumetric data of sections by using a 3D reconstruction algorithm (e.g., filtered back projection). The preliminary quantitative X-ray performance of our CBCT system was investigated by using the American Association of Physicists in Medicine CT phantom in terms of spatial resolution, contrast resolution, and CT number linearity for mobile or fixed C-arm based CBCT application with limited rotational geometry. The novel results of the projection data with different scanning angles and angular increments in the orbital gantry platform were acquired and evaluated experimentally.

  17. Evaluation of image quality and dose on a flat-panel CT-scanner

    Science.gov (United States)

    Grasruck, M.; Suess, Ch.; Stierstorfer, K.; Popescu, S.; Flohr, T.

    2005-04-01

    We developed and evaluated a prototype flat-panel detector based Volume CT (VCT) scanner. We focused on improving the image quality using different detector settings and reducing x-ray scatter intensities. For the presented results we used a Varian 4030CB flat-panel detector mounted in a multislice CT-gantry (Siemens Medical Systems). The scatter intensities may severely impair image quality in flat-panel detector CT systems. To reduce the impact of scatter we tested bowtie shaped filters, anti-scatter grids and post-processing correction algorithms. We evaluated the improvement of image quality by each method and also by a combination of the several methods. To achieve an extended dynamic range in the projection data, we implemented a novel dynamic gain-switching mode. The read out charge amplifier feedback capacitance is changing dynamically in this mode, depending on the signal level. For this scan mode dedicated corrections in the offset and gain calibration are required. We compared image quality in terms of low contrast for both, the dynamic mode and the standard fixed gain mode. VCT scanners require different types of dose parameters. We measured the dose in a 16 cm CTDI phantom and free air in the scanners iso-center and defined a new metric for a VCT dose index (VCTDI). The dose for a high quality VCT scan of this prototype scanner varied between 15 and 40 mGy.

  18. Photodiode forward bias to reduce temporal effects in a-Si based flat panel detectors

    Science.gov (United States)

    Mollov, Ivan; Tognina, Carlo; Colbeth, Richard

    2008-03-01

    Lag and sensitivity modulation are well known temporal artifacts of a-Si photodiode based flat panel detectors. Both effects are caused by charge carriers being trapped in the semiconductor. Trapping and releasing of these carriers is a statistical process with time constants much longer than the frame time of flat panel detectors. One way to reduce these temporal artifacts is to keep the traps filled by applying a pulse of light over the entire detector area every frame before the x-ray exposure. This paper describes an alternative method, forward biasing the a-Si photodiodes and supplying free carriers to fill the traps. The array photodiodes are forward biased and then reversed biased again every frame between the panel readout and x-ray exposure. The method requires no change to the mechanical construction of the detector, only minor modifications of the detector electronics and no image post processing. An existing flat panel detector was modified and evaluated for lag and sensitivity modulation. The required changes of the panel configuration, readout scheme and readout timing are presented in this paper. The results of applying the new technique are presented and compared to the standard mode of operation. The improvements are better than an order of magnitude for both sensitivity modulation and lag; lowering their values to levels comparable to the scintillator afterglow. To differentiate the contribution of the a-Si array, from that of the scintillator, a large area light source was used. Possible implementations and applications of the method are discussed.

  19. Rotational flat-panel computed tomography in diagnostic and interventional neuroradiology

    Energy Technology Data Exchange (ETDEWEB)

    Doerfler, A.; Struffert, T.; Engelhorn, T.; Richter, C. [Abt. fuer Neuroradiologie, Universitaetsklinikum Erlangen, Friedrich-Alexander-Univ. Erlangen-Nuernberg (Germany)

    2008-10-15

    Originally aimed at improving standard radiography by providing higher absorption efficiency and a wider dynamic range than available with X-ray film or film-screen combinations, flat-panel detector technology has become widely accepted for neuroangiographic imaging. In particular flat-panel detector computed tomography (FD-CT) which uses rotational C-arm-mounted flat-panel detector technology is capable of volumetric imaging with high spatial resolution. As ''Angiographic CT'' FD-CT may be helpful during many diagnostic and neurointerventional procedures, i.e. intracranial stenting for cerebrovascular stenoses, stent-assisted coil embolization of wide-necked cerebral aneurysms and embolizations of arteriovenous malformations. By providing morphologic, CT-like images of the brain within the angio suite, FD-CT is able to rapidly visualize periprocedural hemorrhage and may thus improve rapid complication management without the need for patient transfer. In addition, myelography and postmyelographic FD-CT imaging can be carried out using a single machine. Spinal interventions, such as kyphoplasty or vertebroplasty might also benefit from FD-CT. This paper briefly reviews the technical principles of FD technology and then focuses on possible applications in diagnostic and interventional neuroradiology. (orig.)

  20. High-performance flat-panel solar thermoelectric generators with high thermal concentration.

    Science.gov (United States)

    Kraemer, Daniel; Poudel, Bed; Feng, Hsien-Ping; Caylor, J Christopher; Yu, Bo; Yan, Xiao; Ma, Yi; Wang, Xiaowei; Wang, Dezhi; Muto, Andrew; McEnaney, Kenneth; Chiesa, Matteo; Ren, Zhifeng; Chen, Gang

    2011-05-01

    The conversion of sunlight into electricity has been dominated by photovoltaic and solar thermal power generation. Photovoltaic cells are deployed widely, mostly as flat panels, whereas solar thermal electricity generation relying on optical concentrators and mechanical heat engines is only seen in large-scale power plants. Here we demonstrate a promising flat-panel solar thermal to electric power conversion technology based on the Seebeck effect and high thermal concentration, thus enabling wider applications. The developed solar thermoelectric generators (STEGs) achieved a peak efficiency of 4.6% under AM1.5G (1 kW m(-2)) conditions. The efficiency is 7-8 times higher than the previously reported best value for a flat-panel STEG, and is enabled by the use of high-performance nanostructured thermoelectric materials and spectrally-selective solar absorbers in an innovative design that exploits high thermal concentration in an evacuated environment. Our work opens up a promising new approach which has the potential to achieve cost-effective conversion of solar energy into electricity.

  1. Resolution requirements for monitor viewing of digital flat-panel detector radiographs: a contrast detail analysis

    Energy Technology Data Exchange (ETDEWEB)

    Peer, Siegfried; Giacomuzzi, Salvatore M.; Peer, Regina; Gassner, Eva; Steingruber, Iris; Jaschke, Werner [Department of Radiology, University Hospital, Anichstrasse 35, 6020 Innsbruck (Austria)

    2003-02-01

    With the introduction of digital flat-panel detector systems into clinical practice, the still unresolved question of resolution requirements for picture archiving communication system (PACS) workstation monitors has gained new momentum. This contrast detail analysis was thus performed to define the differences in observer performance in the detection of small low-contrast objects on clinical 1K and 2K monitor workstations. Images of the CDRAD 2.0 phantom were acquired at varying exposures on an indirect-type digital flat-panel detector. Three observers evaluated a total of 15 images each with respect to the threshold contrast for each detail size. The numbers of correctly identified objects were determined for all image subsets. No significant difference in the correct detection ratio was detected among the observers; however, the difference between the two types of workstations (1K vs 2K monitors) despite less than 3% was significant at a 95% confidence level. Slight but statistically significant differences exist in the detection of low-contrast nodular details visualized on 1K- and 2K-monitor workstations. Further work is needed to see if this result holds true also for comparison of clinical flat-panel detector images and may, for example, exert an influence on the diagnostic accuracy of chest X-ray readings. (orig.)

  2. SAPHIRE: A New Flat-Panel Digital Mammography Detector With Avalanche Photoconductor and High-Resolution Field Emitter Readout

    Science.gov (United States)

    2006-06-01

    AD_________________ Award Number: W81XWH-04-1-0554 TITLE: SAPHIRE : A New Flat-Panel Digital... SAPHIRE : A New Flat-Panel Digital Mammography Detector with Avalanche Photoconductor and High-Resolution Field Emitter Readout 5b. GRANT NUMBER w81xwh-04...CsI), and form a charge image that is read out by a high-resolution field emitter array (FEA). We call the proposed detector SAPHIRE (Scintillator

  3. Dual-exposure technique for extending the dynamic range of x-ray flat panel detectors.

    Science.gov (United States)

    Sisniega, A; Abella, M; Desco, M; Vaquero, J J

    2014-01-20

    This work presents an approach to extend the dynamic range of x-ray flat panel detectors by combining two acquisitions of the same sample taken with two different x-ray photon flux levels and the same beam spectral configuration. In order to combine both datasets, the response of detector pixels was modelled in terms of mean and variance using a linear model. The model was extended to take into account the effect of pixel saturation. We estimated a joint probability density function (j-pdf) of the pixel values by assuming that each dataset follows an independent Gaussian distribution. This j-pdf was used for estimating the final pixel value of the high-dynamic-range dataset using a maximum likelihood method. The suitability of the pixel model for the representation of the detector signal was assessed using experimental data from a small-animal cone-beam micro-CT scanner equipped with a flat panel detector. The potential extension in dynamic range offered by our method was investigated for generic flat panel detectors using analytical expressions and simulations. The performance of the proposed dual-exposure approach in realistic imaging environments was compared with that of a regular single-exposure technique using experimental data from two different phantoms. Image quality was assessed in terms of signal-to-noise ratio, contrast, and analysis of profiles drawn on the images. The dynamic range, measured as the ratio between the exposure for saturation and the exposure equivalent to instrumentation noise, was increased from 76.9 to 166.7 when using our method. Dual-exposure results showed higher contrast-to-noise ratio and contrast resolution than the single-exposure acquisitions for the same x-ray dose. In addition, image artifacts were reduced in the combined dataset. This technique to extend the dynamic range of the detector without increasing the dose is particularly suited to image samples that contain both low and high attenuation regions.

  4. Designing, Modeling, Constructing, and Testing a Flat Panel Speaker and Sound Diffuser for a Simulator

    Science.gov (United States)

    Dillon, Christina

    2013-01-01

    The goal of this project was to design, model, build, and test a flat panel speaker and frame for a spherical dome structure being made into a simulator. The simulator will be a test bed for evaluating an immersive environment for human interfaces. This project focused on the loud speakers and a sound diffuser for the dome. The rest of the team worked on an Ambisonics 3D sound system, video projection system, and multi-direction treadmill to create the most realistic scene possible. The main programs utilized in this project, were Pro-E and COMSOL. Pro-E was used for creating detailed figures for the fabrication of a frame that held a flat panel loud speaker. The loud speaker was made from a thin sheet of Plexiglas and 4 acoustic exciters. COMSOL, a multiphysics finite analysis simulator, was used to model and evaluate all stages of the loud speaker, frame, and sound diffuser. Acoustical testing measurements were utilized to create polar plots from the working prototype which were then compared to the COMSOL simulations to select the optimal design for the dome. The final goal of the project was to install the flat panel loud speaker design in addition to a sound diffuser on to the wall of the dome. After running tests in COMSOL on various speaker configurations, including a warped Plexiglas version, the optimal speaker design included a flat piece of Plexiglas with a rounded frame to match the curvature of the dome. Eight of these loud speakers will be mounted into an inch and a half of high performance acoustic insulation, or Thinsulate, that will cover the inside of the dome. The following technical paper discusses these projects and explains the engineering processes used, knowledge gained, and the projected future goals of this project

  5. Integration of flat panel X-ray detector for high resolution diagnostic medical imaging

    Science.gov (United States)

    Kim, Min-Woo; Yun, Min-Seok; Kim, Yoon-Suk; Oh, Kyung-Min; Shin, Jung-Wook; Nam, Kyung-Tae; Nam, Sang-Hee

    2011-05-01

    In these days, flat panel X-ray image detectors have shown their potential for replacing traditional screen-film systems. To detect the X-ray photon energy, there are two main methods known as a direct method and an indirect method. The X-rays are converted immediately into electrical signal with the direct method. The indirect method has two conversion steps: the scintillator absorbs the X-rays and converts them to visible light. And then the visible light is converted to electrical signal (e.g. by photodiodes). In this work, the flat panel digital X-ray image detector based on direct method with a high atomic number material was designed and evaluated. The high atomic number material for X-ray conversion is deposited by a rubbing method with about 300 μm. The rubbing method is similar to the screen printing method. It consists of two elements: the screen and the squeegee. The method uses a proper stiff bar stretched tightly over a frame made of wood or metal. Proper tension is essential for proper laminated structure. The detector prototype has 139 μm pixel pitch, total 1280×1536 pixels and 86% fill factor. Twelve readout ICs are installed on digital X-ray detector and simultaneously operated to reach short readout time. The electronics integrated: the preamplifier to amplify generated signal, the Analog to Digital converter and the source of bias voltage (1 V/μm). The system board and interface use an NI-camera program. Finally, we achieved images from this flat panel X-ray image detector.

  6. Image blur in a flat-panel detector due to Compton scattering at its internal mountings

    Science.gov (United States)

    Bub, A.; Gondrom, S.; Maisl, M.; Uhlmann, N.; Arnold, W.

    2007-05-01

    An image-blurring effect observable in digital x-ray flat-panel pixel detectors, used for x-ray computed tomography or radioscopy, has been studied. Our study indicates that the origin of this blurring effect is the Compton scattered radiation within the entrance window, the mounting of the detector scintillator and other parts of the detector. This effect becomes, in particular, noticeable in the presence of a sharp edge of a metallic component being tested, making the scattering in the detector asymmetric.

  7. Autostereoscopic 3D flat panel display using an LCD-pixel-associated parallax barrier

    Science.gov (United States)

    Chen, En-guo; Guo, Tai-liang

    2014-05-01

    This letter reports an autostereoscopic three-dimensional (3D) flat panel display system employing a newly designed LCD-pixel-associated parallax barrier (LPB). The barrier's parameters can be conveniently determined by the LCD pixels and can help to greatly simplify the conventional design. The optical system of the proposed 3D display is built and simulated to verify the design. For further experimental demonstration, a 508-mm autostereoscopic 3D display prototype is developed and it presents good stereoscopic images. Experimental results agree well with the simulation, which reveals a strong potential for 3D display applications.

  8. Perfusion analysis using a wide coverage flat-panel volume CT: feasibility study

    Science.gov (United States)

    Grasruck, M.; Gupta, R.; Reichardt, B.; Klotz, E.; Schmidt, B.; Flohr, T.

    2007-03-01

    We developed a Flat-panel detector based Volume CT (VCT) prototype scanner with large z-coverage. In that prototype scanner a Varian 4030CB a-Si flat-panel detector was mounted in a multi slice CT-gantry (Siemens Medical Solutions) which provides a 25 cm field of view with 18 cm z-coverage at isocenter. The large volume covered in one rotation can be used for visualization of complete organs of small animals, e.g. rabbits. By implementing a mode with continuous scanning, we are able to reconstruct the complete volume at any point in time during the propagation of a contrast bolus. Multiple volumetric reconstructions over time elucidate the first pass dynamics of a bolus of contrast resulting in 4-D angiography and potentially allowing whole organ perfusion analysis. We studied to which extent pixel based permeability and blood volume calculation with a modified Patlak approach was possible. Experimental validation was performed by imaging evolution of contrast bolus in New Zealand rabbits. Despite the short circulation time of a rabbit, the temporal resolution was sufficient to visually resolve various phases of the first pass of the contrast bolus. Perfusion imaging required substantial spatial smoothing but allowed a qualitative discrimination of different types of parenchyma in brain and liver. If a true quantitative analysis is possible, requires further studies.

  9. An iterative algorithm for soft tissue reconstruction from truncated flat panel projections

    Science.gov (United States)

    Langan, D.; Claus, B.; Edic, P.; Vaillant, R.; De Man, B.; Basu, S.; Iatrou, M.

    2006-03-01

    The capabilities of flat panel interventional x-ray systems continue to expand, enabling a broader array of medical applications to be performed in a minimally invasive manner. Although CT is providing pre-operative 3D information, there is a need for 3D imaging of low contrast soft tissue during interventions in a number of areas including neurology, cardiac electro-physiology, and oncology. Unlike CT systems, interventional angiographic x-ray systems provide real-time large field of view 2D imaging, patient access, and flexible gantry positioning enabling interventional procedures. However, relative to CT, these C-arm flat panel systems have additional technical challenges in 3D soft tissue imaging including slower rotation speed, gantry vibration, reduced lateral patient field of view (FOV), and increased scatter. The reduced patient FOV often results in significant data truncation. Reconstruction of truncated (incomplete) data is known an "interior problem", and it is mathematically impossible to obtain an exact reconstruction. Nevertheless, it is an important problem in 3D imaging on a C-arm to address the need to generate a 3D reconstruction representative of the object being imaged with minimal artifacts. In this work we investigate the application of an iterative Maximum Likelihood Transmission (MLTR) algorithm to truncated data. We also consider truncated data with limited views for cardiac imaging where the views are gated by the electrocardiogram(ECG) to combat motion artifacts.

  10. Transmission type flat-panel X-ray source using ZnO nanowire field emitters

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Daokun; Song, Xiaomeng; Zhang, Zhipeng; Chen, Jun, E-mail: stscjun@mail.sysu.edu.cn [State Key Laboratory of Optoelectronic Materials and Technologies, Guangdong Province Key Laboratory of Display Material and Technology, Sun Yat-sen University, Guangzhou 510275 (China); School of Physics and Engineering, Sun Yat-sen University, Guangzhou 510275 (China); Li, Ziping [The First Affiliated Hospital, Sun Yat-sen University, Guangzhou 510275 (China); She, Juncong; Deng, Shaozhi; Xu, Ningsheng [State Key Laboratory of Optoelectronic Materials and Technologies, Guangdong Province Key Laboratory of Display Material and Technology, Sun Yat-sen University, Guangzhou 510275 (China); School of Microelectronics, Sun Yat-sen University, Guangzhou 510275 (China)

    2015-12-14

    A transmission type flat-panel X-ray source in diode structure was fabricated. Large-scale patterned ZnO nanowires grown on a glass substrate by thermal oxidation were utilized as field emitters, and tungsten thin film coated on silica glass was used as the transmission anode. Uniform distribution of X-ray generation was achieved, which benefited from the uniform electron emission from ZnO nanowires. Self-ballasting effect induced by the intrinsic resistance of ZnO nanowire and decreasing of screening effect caused by patterned emitters account for the uniform emission. Characteristic X-ray peaks of W-L lines and bremsstrahlung X-rays have been observed under anode voltages at a range of 18–20 kV, the latter of which were the dominant X-ray signals. High-resolution X-ray images with spatial resolution less than 25 μm were obtained by the flat-panel X-ray source. The high resolution was attributed to the small divergence angle of the emitted X-rays from the transmission X-ray source.

  11. Evaluation of stent visibility by flat panel detector CT in patients treated for intracranial aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Clarencon, Frederic [Groupe Hospitalier Pitie-Salpetriere, Paris (France); Pitie-Salpetriere Hospital, Department of Neuroradiology, Paris (France); Piotin, Michel; Pistocchi, Silvia; Blanc, Raphael [Fondation A. de Rothschild, Paris (France); Babic, Drazenko [Philips Healthcare, Best (Netherlands)

    2012-10-15

    This study aimed to evaluate the visibility of stents using high-resolution computed tomography (CT) acquisitions acquired with flat panel detector (XperCT, Allura series, Philips Healthcare, The Netherlands) for endovascular treatment of intracranial aneurysms. On a 24-month period, 48 patients endovascularly treated by coiling and stenting (59 stents) for intracranial aneurysms were explored by flat panel detector CT technique. A sequence of 620 2D images was acquired over an angle of 240 using a 1,024 x 1,024 pixel matrix detector within a 48-cm field of view. The images were retrospectively analyzed independently by two neuroradiologists. Evaluation criteria were percentage of visualization of the stents and stent deployment (kinking or unsatisfactory deployment of the stent). Evaluation of the stent was feasible for all the patients. Stent visibility by XperCT was overall estimated at 76% of the stent length. Difficulties to analyze the stents were related to coil artifacts but not to packing density or aneurysm location. Stent length visualization was higher when the acquisition was performed before additional coiling (P < 0.0001). Mild kinking/misdeployment was noticed in 22% of the cases. XperCT technique provides multiplanar and 3D reconstructions that allows for a satisfying visualization of intracranial stents. This CT-like acquisition should be performed after the stent deployment and before coiling, in order to obtain better stent visualization. (orig.)

  12. View-dependent geometric calibration for offset flat-panel cone beam computed tomography systems

    Science.gov (United States)

    Nguyen, Van-Giang

    2016-04-01

    Geometric parameters that define the geometry of imaging systems are crucial for image reconstruction and image quality in x-ray computed tomography (CT). The problem of determining geometric parameters for an offset flat-panel cone beam CT (CBCT) system, a recently introduced modality with a large field of view, with the assumption of an unstable mechanism and geometric parameters that vary in each view, is considered. To accurately and rapidly find the geometric parameters for each projection view, we use the projection matrix method and design a dedicated phantom that is partially visible in all projection views. The phantom consists of balls distributed symmetrically in a cylinder to ensure the inclusion of the phantom in all views, and a large portion of the phantom is covered in the projection image. To efficiently use calibrated geometric information in the reconstruction process and get rid of approximation errors, instead of decomposing the projection matrix into actual geometric parameters that are manually corrected before being used in reconstruction, as in conventional methods, we directly use the projection matrix and its pseudo-inverse in projection and backprojection operations of reconstruction algorithms. The experiments illustrate the efficacy of the proposed method with a real offset flat-panel CBCT system in dental imaging.

  13. AAPM/RSNA physics tutorial for residents: physics of flat-panel fluoroscopy systems: Survey of modern fluoroscopy imaging: flat-panel detectors versus image intensifiers and more.

    Science.gov (United States)

    Nickoloff, Edward Lee

    2011-01-01

    This article reviews the design and operation of both flat-panel detector (FPD) and image intensifier fluoroscopy systems. The different components of each imaging chain and their functions are explained and compared. FPD systems have multiple advantages such as a smaller size, extended dynamic range, no spatial distortion, and greater stability. However, FPD systems typically have the same spatial resolution for all fields of view (FOVs) and are prone to ghosting. Image intensifier systems have better spatial resolution with the use of smaller FOVs (magnification modes) and tend to be less expensive. However, the spatial resolution of image intensifier systems is limited by the television system to which they are coupled. Moreover, image intensifier systems are degraded by glare, vignetting, spatial distortions, and defocusing effects. FPD systems do not have these problems. Some recent innovations to fluoroscopy systems include automated filtration, pulsed fluoroscopy, automatic positioning, dose-area product meters, and improved automatic dose rate control programs. Operator-selectable features may affect both the patient radiation dose and image quality; these selectable features include dose level setting, the FOV employed, fluoroscopic pulse rates, geometric factors, display software settings, and methods to reduce the imaging time.

  14. Lateral amorphous selenium metal-insulator-semiconductor-insulator-metal photodetectors using ultrathin dielectric blocking layers for dark current suppression

    Science.gov (United States)

    Chang, Cheng-Yi; Pan, Fu-Ming; Lin, Jian-Siang; Yu, Tung-Yuan; Li, Yi-Ming; Chen, Chieh-Yang

    2016-12-01

    We fabricated amorphous selenium (a-Se) photodetectors with a lateral metal-insulator-semiconductor-insulator-metal (MISIM) device structure. Thermal aluminum oxide, plasma-enhanced chemical vapor deposited silicon nitride, and thermal atomic layer deposited (ALD) aluminum oxide and hafnium oxide (ALD-HfO2) were used as the electron and hole blocking layers of the MISIM photodetectors for dark current suppression. A reduction in the dark current by three orders of magnitude can be achieved at electric fields between 10 and 30 V/μm. The effective dark current suppression is primarily ascribed to electric field lowering in the dielectric layers as a result of charge trapping in deep levels. Photogenerated carriers in the a-Se layer can be transported across the blocking layers to the Al electrodes via Fowler-Nordheim tunneling because a high electric field develops in the ultrathin dielectric layers under illumination. Since the a-Se MISIM photodetectors have a very low dark current without significant degradation in the photoresponse, the signal contrast is greatly improved. The MISIM photodetector with the ALD-HfO2 blocking layer has an optimal signal contrast more than 500 times the contrast of the photodetector without a blocking layer at 15 V/μm.

  15. A typical flat-panel membrane bioreactor with a composite membrane for sulfur removal

    Science.gov (United States)

    Guan, Jian; Xiao, Yuan; Song, Jimin; Miao, Junhe

    2014-03-01

    The aim of this work was to provide a concrete study to understand the effects of operation on biofilm morphology and microstructure and degradation efficiency for the disposal of sulfur dioxide produced by coal-fired power plants. For this purpose, a flat-panel reactor-membrane bioreactor (MBR) with a composite membrane consisting of a dense layer and a support layer was designed; the membrane bioreactors inoculated with Thiobacillus ferrooxidans were further conducted for the removal of sulfur dioxide. Dry weight, active biomass, pressure drop, removal efficiency, morphology and structure of the formed biofilms were investigated and analyzed over period of biofilm formation. The results found that the dry weight, biomass, pressure drops and removal efficiency increased rapidly during biofilm formation, remained relatively stable in the stabilization period of biofilm growth, and finally reached 0.085 g, 7.00 μg, 180 Pa, and 78%, respectively. Our results suggested the MBR is available for flue-gas desulfurization.

  16. Comparison of flat-panel detector and image-intensifier detector for cone-beam CT.

    Science.gov (United States)

    Baba, Rika; Konno, Yasutaka; Ueda, Ken; Ikeda, Shigeyuki

    2002-01-01

    We evaluated a flat-panel detector (FPD) (scintillator screen and a-Si photo-sensor array) for use in a cone-beam computed tomography (CT) detector and compared it with an image-intensifier detector (IID). The FPD cone-beam CT system has a higher spatial resolution than the IID system. At equal pixel sizes, the standard deviation of noise intensity of the FPD system is equal to that of the IID system. However, the circuit noise of the FPD must be reduced, especially at low doses. Our evaluations show that the FPD system has a strong potential for use as a cone-beam CT detector because of high-spatial resolution.

  17. Combination of CT scanning and fluoroscopy imaging on a flat-panel CT scanner

    Science.gov (United States)

    Grasruck, M.; Gupta, R.; Reichardt, B.; Suess, Ch.; Schmidt, B.; Stierstorfer, K.; Popescu, S.; Brady, T.; Flohr, T.

    2006-03-01

    We developed and evaluated a prototype flat-panel detector based Volume CT (fpVCT) scanner. The fpVCT scanner consists of a Varian 4030CB a-Si flat-panel detector mounted in a multi slice CT-gantry (Siemens Medical Solutions). It provides a 25 cm field of view with 18 cm z-coverage at the isocenter. In addition to the standard tomographic scanning, fpVCT allows two new scan modes: (1) fluoroscopic imaging from any arbitrary rotation angle, and (2) continuous, time-resolved tomographic scanning of a dynamically changing viewing volume. Fluoroscopic imaging is feasible by modifying the standard CT gantry so that the imaging chain can be oriented along any user-selected rotation angle. Scanning with a stationary gantry, after it has been oriented, is equivalent to a conventional fluoroscopic examination. This scan mode enables combined use of high-resolution tomography and real-time fluoroscopy with a clinically usable field of view in the z direction. The second scan mode allows continuous observation of a timeevolving process such as perfusion. The gantry can be continuously rotated for up to 80 sec, with the rotation time ranging from 3 to 20 sec, to gather projection images of a dynamic process. The projection data, that provides a temporal log of the viewing volume, is then converted into multiple image stacks that capture the temporal evolution of a dynamic process. Studies using phantoms, ex vivo specimens, and live animals have confirmed that these new scanning modes are clinically usable and offer a unique view of the anatomy and physiology that heretofore has not been feasible using static CT scanning. At the current level of image quality and temporal resolution, several clinical applications such a dynamic angiography, tumor enhancement pattern and vascularity studies, organ perfusion, and interventional applications are in reach.

  18. Modelling of scintillator based flat-panel detectors with Monte-Carlo simulations

    Science.gov (United States)

    Reims, N.; Sukowski, F.; Uhlmann, N.

    2011-01-01

    Scintillator based flat panel detectors are state of the art in the field of industrial X-ray imaging applications. Choosing the proper system and setup parameters for the vast range of different applications can be a time consuming task, especially when developing new detector systems. Since the system behaviour cannot always be foreseen easily, Monte-Carlo (MC) simulations are keys to gain further knowledge of system components and their behaviour for different imaging conditions. In this work we used two Monte-Carlo based models to examine an indirect converting flat panel detector, specifically the Hamamatsu C9312SK. We focused on the signal generation in the scintillation layer and its influence on the spatial resolution of the whole system. The models differ significantly in their level of complexity. The first model gives a global description of the detector based on different parameters characterizing the spatial resolution. With relatively small effort a simulation model can be developed which equates the real detector regarding signal transfer. The second model allows a more detailed insight of the system. It is based on the well established cascade theory, i.e. describing the detector as a cascade of elemental gain and scattering stages, which represent the built in components and their signal transfer behaviour. In comparison to the first model the influence of single components especially the important light spread behaviour in the scintillator can be analysed in a more differentiated way. Although the implementation of the second model is more time consuming both models have in common that a relatively small amount of system manufacturer parameters are needed. The results of both models were in good agreement with the measured parameters of the real system.

  19. Application of the Monte Carlo method to analyze materials used in flat panel detectors to obtain X-ray spectra

    Science.gov (United States)

    Gallardo, Sergio; Pozuelo, Fausto; Querol, Andrea; Ródenas, José; Verdú, Gumersindo

    2014-06-01

    An accurate knowledge of the photon spectra emitted by X-ray tubes in radiodiagnostic is essential to better estimate the imparted dose to patients and to improve the quality image obtained with these devices. In this work, it is proposed the use of a flat panel detector together with a PMMA wedge to estimate the actual X-ray spectrum using the Monte Carlo method and unfolding techniques. The MCNP5 code has been used to model different flat panels (based on indirect and direct methods to produce charge carriers from absorbed X-rays) and to obtain the dose curves and system response functions. Most of the actual flat panel devices use scintillator materials that present K-edge discontinuities in the mass energy-absorption coefficient, which strongly affect the response matrix. In this paper, the applicability of different flat panels for reconstructing X-ray spectra is studied. The effect of the mass energy-absorption coefficient of the scintillator material has been studied on the response matrix and consequently, in the reconstructed spectra. Different unfolding methods are tested to reconstruct the actual X-ray spectrum knowing the dose curve and the response function. It has been concluded that the regularization method MTSVD is appropriate to unfold X-ray spectra in all the scintillators studied.

  20. A ghost story: spatio-temporal response characteristics of an indirect-detection flat-panel imager.

    Science.gov (United States)

    Siewerdsen, J H; Jaffray, D A

    1999-08-01

    Spatial and temporal imaging characteristics of an amorphous silicon flat-panel imager (FPI) were investigated in terms relevant to the application of such devices in cone-beam computed tomography (CBCT) and other x-ray imaging modalities, including general radiography, fluoroscopy, mammography, radiotherapy portal imaging, and nondestructive testing. Specifically, issues of image lag (including the magnitude, spatial uniformity, temporal-frequency characteristics, and dependence upon exposure and frame time) and long-term image persistence ("ghosts") were investigated. As part of the basic characterization of the FPI, pixel dark signal and noise (magnitude, temporal stability, and spatial uniformity) as well as radiation response (signal size, linearity, gain, and reciprocity) were also measured. Image lag was analyzed as a function of frame time and incident exposure. First-frame lag (i.e., the relative residual signal in the first frame following readout of an exposure) was approximately 2-10%, depending upon incident exposure and was spatially nonuniform to a slight degree across the FPI; second-, third-, and fourth-frame lag were approximately 0.7%, 0.4%, and 0.3%, respectively (at 25% sensor saturation). Image lag was also analyzed in terms of the temporal-frequency-dependent transfer function derived from the radiation response, allowing a quantitative description of system components contributing to lag. Finally, the contrast of objects as a function of time following an exposure was measured in order to examine long-term image persistence ("ghosts"). Ghosts were found to persist up to 30 min or longer, depending upon the exposure and frame time. Two means of reducing the apparent contrast of ghost images were tested: (i) rapid scanning of the FPI at maximum frame rate, and (ii) flood-field exposure of the FPI; neither was entirely satisfactory. These results pose important considerations for application of FPIs in CBCT as well as other x-ray imaging

  1. Comparison of ring artifact removal methods using flat panel detector based CT images

    Directory of Open Access Journals (Sweden)

    Lee Soo Y

    2011-08-01

    Full Text Available Abstract Background Ring artifacts are the concentric rings superimposed on the tomographic images often caused by the defective and insufficient calibrated detector elements as well as by the damaged scintillator crystals of the flat panel detector. It may be also generated by objects attenuating X-rays very differently in different projection direction. Ring artifact reduction techniques so far reported in the literature can be broadly classified into two groups. One category of the approaches is based on the sinogram processing also known as the pre-processing techniques and the other category of techniques perform processing on the 2-D reconstructed images, recognized as the post-processing techniques in the literature. The strength and weakness of these categories of approaches are yet to be explored from a common platform. Method In this paper, a comparative study of the two categories of ring artifact reduction techniques basically designed for the multi-slice CT instruments is presented from a common platform. For comparison, two representative algorithms from each of the two categories are selected from the published literature. A very recently reported state-of-the-art sinogram domain ring artifact correction method that classifies the ring artifacts according to their strength and then corrects the artifacts using class adaptive correction schemes is also included in this comparative study. The first sinogram domain correction method uses a wavelet based technique to detect the corrupted pixels and then using a simple linear interpolation technique estimates the responses of the bad pixels. The second sinogram based correction method performs all the filtering operations in the transform domain, i.e., in the wavelet and Fourier domain. On the other hand, the two post-processing based correction techniques actually operate on the polar transform domain of the reconstructed CT images. The first method extracts the ring artifact template

  2. Detector evaluation of a prototype amorphous selenium-based full field digital mammography system

    Science.gov (United States)

    Jesneck, Jonathan L.; Saunders, Robert S.; Samei, Ehsan; Xia, Jessie Q.; Lo, Joseph Y.

    2005-04-01

    This study evaluated the physical performance of a selenium-based direct full-field digital mammography prototype detector (Siemens Mammomat NovationDR), including the pixel value vs. exposure linearity, the modulation transfer function (MTF), the normalized noise power spectrum (NNPS), and the detective quantum efficiency (DQE). The current detector is the same model which received an approvable letter from FDA for release to the US market. The results of the current prototype are compared to those of an earlier prototype. Two IEC standard beam qualities (RQA-M2: Mo/Mo, 28 kVp, 2 mm Al; RQA-M4: Mo/Mo, 35 kVp, 2 mm Al) and two additional beam qualities (MW2: W/Rh, 28 kVp, 2 mm Al; MW4: W/Rh, 35 kVp, 2 mm Al) were investigated. To calculate the modulation transfer function (MTF), a 0.1 mm Pt-Ir edge was imaged at each beam quality. Detector pixel values responded linearly against exposure values (R2 0.999). As before, above 6 cycles/mm Mo/Mo MTF was slightly higher along the chest-nipple axis compared to the left-right axis. MTF was comparable to the previously reported prototype, with slightly reduced resolution. The DQE peaks ranged from 0.71 for 3.31 μC/kg (12.83 mR) to 0.4 for 0.48 μC/kg (1.86 mR) at 1.75 cycles/mm for Mo/Mo at 28 kVp. The DQE range for W/Rh at 28 kVP was 0.81 at 2.03 μC/kg (7.87 mR) to 0.50 at 0.50 μC/kg (1.94 mR) at 1 cycle/mm. NNPS tended to increase with greater exposures, while all exposures had a significant low-frequency component. Bloom and detector edge artifacts observed previously were no longer present in this prototype. The new detector shows marked noise improvement, with slightly reduced resolution. There remain artifacts due to imperfect gain calibration, but at a reduced magnitude compared to a prototype detector.

  3. Investigation of time-resolved proton radiography using x-ray flat-panel imaging system

    Science.gov (United States)

    Jee, K.-W.; Zhang, R.; Bentefour, E. H.; Doolan, P. J.; Cascio, E.; Sharp, G.; Flanz, J.; Lu, H.-M.

    2017-03-01

    Proton beam therapy benefits from the Bragg peak and delivers highly conformal dose distributions. However, the location of the end-of-range is subject to uncertainties related to the accuracy of the relative proton stopping power estimates and thereby the water-equivalent path length (WEPL) along the beam. To remedy the range uncertainty, an in vivo measurement of the WEPL through the patient, i.e. a proton-range radiograph, is highly desirable. Towards that goal, we have explored a novel method of proton radiography based on the time-resolved dose measured by a flat panel imager (FPI). A 226 MeV pencil beam and a custom-designed range modulator wheel (MW) were used to create a time-varying broad beam. The proton imaging technique used exploits this time dependency by looking at the dose rate at the imager as a function of time. This dose rate function (DRF) has a unique time-varying dose pattern at each depth of penetration. A relatively slow rotation of the MW (0.2 revolutions per second) and a fast image acquisition (30 frames per second, ~33 ms sampling) provided a sufficient temporal resolution for each DRF. Along with the high output of the CsI:Tl scintillator, imaging with pixel binning (2  ×  2) generated high signal-to-noise data at a very low radiation dose (~0.1 cGy). Proton radiographs of a head phantom and a Gammex CT calibration phantom were taken with various configurations. The results of the phantom measurements show that the FPI can generate low noise and high spatial resolution proton radiographs. The WEPL values of the CT tissue surrogate inserts show that the measured relative stopping powers are accurate to ~2%. The panel did not show any noticeable radiation damage after the accumulative dose of approximately 3831 cGy. In summary, we have successfully demonstrated a highly practical method of generating proton radiography using an x-ray flat panel imager.

  4. Potential Applications of Flat-Panel Volumetric CT in Morphologic, Functional Small Animal Imaging

    Directory of Open Access Journals (Sweden)

    Susanne Greschus

    2005-08-01

    Full Text Available Noninvasive radiologic imaging has recently gained considerable interest in basic, preclinical research for monitoring disease progression, therapeutic efficacy. In this report, we introduce flat-panel volumetric computed tomography (fpVCT as a powerful new tool for noninvasive imaging of different organ systems in preclinical research. The three-dimensional visualization that is achieved by isotropic high-resolution datasets is illustrated for the skeleton, chest, abdominal organs, brain of mice. The high image quality of chest scans enables the visualization of small lung nodules in an orthotopic lung cancer model, the reliable imaging of therapy side effects such as lung fibrosis. Using contrast-enhanced scans, fpVCT displayed the vascular trees of the brain, liver, kidney down to the subsegmental level. Functional application of fpVCT in dynamic contrast-enhanced scans of the rat brain delivered physiologically reliable data of perfusion, tissue blood volume. Beyond scanning of small animal models as demonstrated here, fpVCT provides the ability to image animals up to the size of primates.

  5. Multi-cusp ion source for doping process of flat panel display manufacturing

    Energy Technology Data Exchange (ETDEWEB)

    Inouchi, Yutaka, E-mail: inouchi-yutaka@nissin.co.jp; Matsumoto, Takeshi; Dohi, Shojiro; Tanii, Masahiro; Takahashi, Genki; Nishimura, Ippei; Tatemichi, Junichi; Konishi, Masashi; Naito, Masao [FPD Machine Business Center, Nissin Ion Equipment Co., Ltd., Shiga 528-0068 (Japan)

    2014-02-15

    We developed a multi-cusp ion source for Nissin ion doping system iG5 which is used in low temperature poly-crystalline silicon processes for flat panel display (FPD) manufacturing. In this ion source, BF{sub 3} or PH{sub 3} diluted H{sub 2} plasmas are produced and large area ribbon ion beams are extracted. In general, ion ratio of B{sup +} in BF{sub 3} plasma is much smaller than BF{sub 2}{sup +} in multi-cusp ion sources. We developed a new method to increase B{sup +} ratio and obtained mass analyzed B{sup +} target current of 130 mA. We employed newly improved multi-slot type electrodes for the beam extraction system and obtained stable beams with the uniformity of below 3%. In BF{sub 3} plasmas, several undesirable metal fluorides are produced in the plasma chamber and deposited on the electrode system, which cause glitches and poor beam uniformity. We introduce several cleaning methods.

  6. Flat panel CT following stapes prosthesis insertion: an experimental and clinical study

    Energy Technology Data Exchange (ETDEWEB)

    Zaoui, K. [University-Hospital Heidelberg, Ludwig-Karls-University Heidelberg, Department of Otorhinolaryngology, Head and Neck Surgery, Heidelberg (Germany); Kromeier, J. [St.-Josefs-Hospital, RkK, Department of Radiology, Freiburg (Germany); Neudert, M.; Zahnert, T. [University-Hospital Dresden, Technical-University Dresden, Department of Otorhinolaryngology, Head and Neck Surgery, Dresden (Germany); Boedeker, C.C.; Laszig, R.; Offergeld, C. [University-Hospital Freiburg, Albert-Ludwigs-University Freiburg, Department of Otorhinolaryngology, Head and Neck Surgery, Freiburg (Germany)

    2012-04-15

    Anatomical information of the middle and inner ear is becoming increasingly important in post-operative evaluation especially after stapesplasty with unsuccessful improvement of the air-bone gap (ABG). So far computed tomography (CT) has been the first choice for detection of reasons for recurrent hearing loss. CT has the disadvantage of metal-induced artefacts after insertion of middle ear implants and of a relatively high irradiation dose. Flat panel CT (fpCT) was performed in three temporal bone specimen after experimental insertion of different stapes prostheses, aiming to validate the accuracy of fpCT of the middle and inner ear. Additionally, 28 consecutive patients, supplied with different stapes prostheses underwent post-operative fpCT to compare the pre- and post-operative hearing results with the determined prosthesis position in the middle and inner ear. In all cases, fpCT showed a statistically significant correlation between hearing improvement and prosthesis position. This technique provided detailed post-operative information of the implant position in patients and temporal bone specimen. The new imaging technique of fpCT allows the immediate and almost artefact-free evaluation of surgical results following stapesplasty. Further benefits are a lower irradiation dose and higher isovolumetric resolution compared with standard CT. (orig.)

  7. Clinical investigation of flat panel CT following middle ear reconstruction: a study of 107 patients

    Energy Technology Data Exchange (ETDEWEB)

    Zaoui, K. [University Hospital Heidelberg, Ruprecht Karls University, Department of Otorhinolaryngology, Head and Neck Surgery, Heidelberg (Germany); Kromeier, J. [St. Josefs Hospital, RkK, Department of Radiology, Freiburg (Germany); Neudert, M.; Beleites, T.; Zahnert, T. [University Hospital Dresden, Technical University, Department of Otorhinolaryngology, Head and Neck Surgery, Dresden (Germany); Laszig, R.; Offergeld, C. [University Hospital Freiburg, Albert Ludwigs University, Department of Otorhinolaryngology, Head and Neck Surgery, Freiburg (Germany)

    2014-03-15

    After middle ear reconstruction using partial or total ossicular replacement prostheses (PORP/TORP), an air-bone gap (ABG) may persist because of prosthesis displacement or malposition. So far, CT of the temporal bone has played the main role in the diagnosis of reasons for postoperative insufficient ABG improvement. Recent experimental and clinical studies have evaluated flat panel CT (fpCT) as an alternative imaging technique that provides images with high isovolumetric resolution, fewer metal-induced artefacts and lower irradiation doses. One hundred and seven consecutive patients with chronic otitis media with or without cholesteatoma underwent reconstruction by PORP (n = 52) or TORP (n = 55). All subjects underwent preoperative and postoperative audiometric testing and postoperative fpCT. Statistical evaluation of all 107 patients as well as the sole sub-assembly groups (PORP or TORP) showed a highly significant correlation between hearing improvement and fpCT-determined prosthesis position. FpCT enables detailed postoperative information on patients with middle ear reconstruction. FpCT is a new imaging technique that provides immediate feedback on surgical results after reconstructive middle ear surgery. Specific parameters evaluated by fpCT may serve as a predictive tool for estimated postoperative hearing improvement. Therefore this imaging technique is suitable for postoperative quality control in reconstructive middle ear surgery. (orig.)

  8. MTF compensation for digital radiography system with indirect conversion flat panel detector

    Science.gov (United States)

    Zhang, Wei; Souchay, Henri; Yang, Chao

    2009-02-01

    The MTF (modulation transfer function) of digital radiography systems can be enhanced in the spatial frequency domain due to their high signal to noise ratio. A Wiener filter, which requires prior estimation of the noise and signal power spectrum of the images, was used to compensate MTF of the detector and thereby optimally restore the images details. We studied the noise characteristics of two flat panel detectors with structured columnar scintillator (CsI) and granular scintillator (Gd2O2S). A noise model formulating noise transfer process was applied to estimate the noise components for the filter. Signal model was based on dose of the application. We revisited the noise and signal model that was used in previous work by Souchay et al. for mammography application [1], considering the difference in detector characteristics and the applications (extremity x-ray) that we are specifically investigating. Starting with real clinical images, we used an observer study method to measure the visually optimal parameter for the Wiener filter. A set of clinical images was used to evaluate the radiologists' preferences to compensated images against the reference images. Statistical results from three experienced radiologists ranking results show that the compensated images are preferred over the reference images.

  9. An Output Channel Nonuniformity Compensation Driving Method in Flat Panel Display Driving Circuits

    Science.gov (United States)

    Kim, Jin-Ho; Ahn, Soon-Sung; Kwon, Christine H.; Kim, Seon-Yung; Lee, Jae-Sic; Choi, Byong-Deok

    2006-12-01

    Modern flat panel displays, including thin-film transistor liquid crystal displays (TFT-LCDs) and organic light-emitting diodes (OLEDs), pursue more and more natural color expression. This requires the data driving system should produce very fine and accurate signal voltages or currents. Especially, the uniformity among channels of a driving system is critically important because the color or luminance differences among columns are easily noticeable. We propose a simple and efficient driving method for solving the artifacts caused by the existing nonuniformity among channels of a driving system, and confirms its impact by simulations using C-programming. The nonuniformity among channels mostly stem from the random offset of the output circuits of a driving system, which in turn is caused by the process variations. The proposed driving method shares N-output circuits between N-output channels such that the existing offsets of the channels are averaged out. Thus, the output signal error due to the offsets spreads out among the channels, improving the uniformity between the channels.

  10. Practical expressions describing detective quantum efficiency in flat-panel detectors

    Science.gov (United States)

    Kim, H. K.

    2011-11-01

    In radiology, image quality excellence is a balance between system performance and patient dose, hence x-ray systems must be designed to ensure the maximum image quality is obtained for the lowest consistent dose. The concept of detective quantum efficiency (DQE) is widely used to quantify, understand, measure, and predict the performance of x-ray detectors and imaging systems. Cascaded linear-systems theory can be used to estimate DQE based on the system design parameters and this theoretical DQE can be utilized for determining the impact of various physical processes, such as secondary quantum sinks, noise aliasing, reabsorption noise, and others. However, the prediction of DQE usually requires tremendous efforts to determine each parameter consisting of the cascaded linear-systems model. In this paper, practical DQE formalisms assessing both the photoconductor- and scintillator-based flat-panel detectors under quantum-noise-limited operation are described. The developed formalisms are experimentally validated and discussed for their limits. The formalisms described in this paper would be helpful for the rapid prediction of the DQE performances of developing systems as well as the optimal design of systems.

  11. [C-MOS flat-panel sensor for real time X-ray imaging].

    Science.gov (United States)

    Nakagawa, K; Aoki, Y; Sasaki, Y; Akanuma, A; Mizuno, S

    1998-02-01

    Flat-panel, self-scanning, solid state diagnostic x-ray imaging devices using complementary metal-oxide-semiconductor (C-MOS) arrays are under investigation. A unit device with a 5 cm by 5 cm sensor area was developed and tested. The device consists of a CsI scintillator and C-MOS detector arrays. The detector arrays are composed of a regular arrangement of pixels (256 x 256), each of which is made of a C-MOS photodiode sensor coupled to a C-MOS FET (field effect transistor). A common FET gate line is connected to all the FET gates along each column. A common date line is connected to all the FET drains of each row. The source contact of each FET is connected to that of its corresponding photodiode. A positive gate pulse applied to a gate turns on all FETs connected to the date lines. The readout continues column by column. Correlated double sampling circuits and an offset variance compensation circuit were installed to reduce noise. A sampling speed of 15 frames per second and spatial resolution of 2.5 line per mm were achieved. Noise level and maximum signal were 1.5 mV rms and 1.8 V, respectively. Image quality was considered acceptable for clinical use. It is also discussed how to fabricate a large area sensor with the unit device.

  12. Reliability of myocardial perfusion quantification in angiography using a digital flat panel cardiac system

    Science.gov (United States)

    Perrin, Muriel; Vaillant, Regis; Gavit-Houdant, Laurence; Lienard, Jean; Benali, Karim

    2002-04-01

    Discordance between lesion severity from angiocardiography and physiological effects has been reported elsewhere. Quantification of myocardial perfusion during the angiography procedure may supply additional information about short- and long-term outcomes and may be helpful for clinical decision making. In previous works, myocardial perfusion has been assessed using time density curves (TDC), which represent the contrast medium dilution over time in the myocardium. The mean transit time (MTT), derived from the TDC, has been reported as a good indicator of the regional myocardial perfusion. Our objective is to estimate the accuracy and reproducibility of MTT estimation on digital flat panel (DFP) images. We have simulated typical myocardium TDC obtained with a DFP cardiac system (Innova 2000, GE), taking into account scatter and noise. Logarithmic or linear subtractions have been applied to derive a contrast medium concentration proportional quantity from image intensity. A non-linear minimisation realises the model curve fitting. MTT estimates are more stable with linear subtraction in presence of scatter. However logarithmic subtraction presents smaller bias when scatter level is small. Both approaches are equally sensible to image noise. Linear subtraction should be preferred. Image noise has a high influence on MTT accuracy and we may reduce.

  13. Continuous production of diatom Entomoneis sp. in mechanically stirred tank and flat-panel airlift photobioreactors.

    Science.gov (United States)

    Viriyayingsiri, Thunyaporn; Sittplangkoon, Pantaporn; Powtongsook, Sorawit; Nootong, Kasidit

    2016-10-02

    Continuous production of diatom Entomonies sp. was performed in mechanically stirred tank and flat-panel airlift photobioreactors (FPAP). The maximum specific growth rate of diatom from the batch experiment was 0.98 d(-1). A series of dilution rate and macronutrient concentration adjustments were performed in a stirred tank photobioreactor and found that the dilution rate ranged from 0.7 to 0.8 d(-1) and modified F/2 growth media containing nitrate at 3.09 mg N/L, phosphate at 2.24 mg P/L, and silicate at 11.91 mg Si/L yielded the maximum cell number density. Finally, the continuous cultivation of Entomonies sp. was conducted in FPAP using the optimal conditions determined earlier, resulting in the maximum cell number density of 19.69 × 10(4) cells/mL, which was approximately 47 and 73% increase from the result using the stirred tank photobioreactor fed with modified and standard F/2 growth media, respectively.

  14. Astaxanthin induction in Microalga H. pluvialis with flat panel airlift photobioreactors under indoor and outdoor conditions.

    Science.gov (United States)

    Poonkum, Woradej; Powtongsook, Sorawit; Pavasant, Prasert

    2015-01-01

    Astaxanthin was induced from Haematococcus pluvialis (NIES-144) under indoor and outdoor conditions using 17-, 50-, and 90-L flat-panel airlift photobioreactors (FP-APBRs). Preliminary experiments in 1.5-L bubble column photobioreactors (BC-PBRs) revealed that sterilized clean water with 3% CO2 aeration (1.47 cm(3) s(-1) CO2 loading) could best encourage astaxanthin accumulation at 18.21 g m(-3) (3.63% by weight). Operating 17-L FP-APBRs with these bubble column parameters under indoor conditions could further enhance astaxanthin to 26.63 g m(-3) (5.34% by weight). This was potentially due to the inherited up-lift force from the reactor that helped avoid cell precipitation by allowing the cells to be circulated within the reactor. In addition, the various sizes of FP-APBRs exhibited similar performance, implying a potential scale-up opportunity. However, similar operation under outdoor condition exhibited slightly poorer performance due to the light inhibition effect. The best outdoor performance was obtained with the FP-APBR covered with one layer of shading net, where 20.11 g m(-3) (4.47% by weight) of astaxanthin was resulted.

  15. Effect of oblique X-ray incidence in flat-panel computed tomography of the breast.

    Science.gov (United States)

    Badano, Aldo; Kyprianou, Iacovos S; Freed, Melanie; Jennings, Robert J; Sempau, Josep

    2009-05-01

    We quantify the variation in resolution due to anisotropy caused by oblique X-ray incidence in indirect flat-panel detectors for computed tomography breast imaging systems. We consider a geometry and detector type utilized in breast computed tomography (CT) systems currently being developed. Our methods rely on mantis, a combined X-ray, electron, and optical Monte Carlo transport open source code. The physics models are the most accurate available in general-purpose Monte Carlo packages in the diagnostic energy range. We consider maximum-obliquity angles of 10 ( degrees ) and 13 ( degrees ) at the centers of the 30 and 40 cm detector edges, respectively, and 16 ( degrees ) at the corner of the detector. Our results indicate that blur is asymmetric and that the resolution properties vary significantly with the angle (or location) of incidence. Our results suggest that the asymmetry can be as high as a factor of 2.6 between orthogonal directions. Anisotropy maps predicted by mantis provide an understanding of the effect that such variations have on the imaging system and allow more accurate modeling and optimization of breast CT systems. These maps of anisotropy across the detector could lead to improved reconstruction and help motivate physics-based strategies for computer detection of breast lesions.

  16. Optimizing the tube potential for lumbar spine radiography with a flat-panel digital detector.

    Science.gov (United States)

    Geijer, H; Norrman, E; Persliden, J

    2009-01-01

    The purpose of this study was to find the optimal settings for lumbar spine radiography with a flat-panel detector. A CDRAD contrast-detail phantom was imaged at various tube potentials, system speeds and filtration settings. Factorial experiments yielded a range of optimized exposure settings, which were submitted to visual grading analysis with images of an Alderson phantom. The first optimized settings involved a system speed increase from 400 to 800. For anteroposterior projection, the optimal tube potential was reduced from the default of 77 kV to 60 kV to give the best image quality without increasing the effective dose, or to 66 kV to give the lowest dose without reducing image quality. For lateral projection, the tube potential was similarly reduced from the default of 90 kV to 70 kV or 77 kV. Visual grading analysis confirmed the results, with significantly better image quality when optimizing for image quality. The study thus shows that the tube potential can be reduced as long as the system speed is increased simultaneously. This leads to a lower effective dose and/or increased image quality depending on the settings chosen. The factorial experiments provided a powerful way to evaluate several parameters concomitantly.

  17. Dual-Energy Subtraction Imaging for Diagnosing Vocal Cord Paralysis with Flat Panel Detector Radiography

    Energy Technology Data Exchange (ETDEWEB)

    Machida, Haruhiko; Yoda, Keiko; Arai, Yasuko [Tokyo Women' s Medical University Medical Center East, Tokyo (Japan)] (and others)

    2010-06-15

    To investigate the clinical feasibility of dual energy subtraction (DES) imaging to improve the delineation of the vocal cord and diagnostic accuracy of vocal cord paralysis as compared with the anterior-posterior view of flat panel detector (FPD) neck radiography. For 122 consecutive patients who underwent both a flexible laryngoscopy and conventional/DES FPD radiography, three blinded readers retrospectively graded the radiographs during phonation and inspiration on a scale of 1 (poor) to 5 (excellent) for the delineation of the vocal cord, and in consensus, reviewed the diagnostic accuracy of vocal cord paralysis employing the laryngoscopy as the reference. We compared vocal cord delineation scores and accuracy of vocal cord paralysis diagnosis by both conventional and DES techniques using ({kappa}statistics and assessing the area under the receiver operating characteristic curve (AUC). Vocal cord delineation scores by DES (mean, 4.2 {+-} 0.4) were significantly higher than those by conventional imaging (mean, 3.3 {+-} 0.5) (p < 0.0001). Sensitivity for diagnosing vocal cord paralysis by the conventional technique was 25%, whereas the specificity was 94%. Sensitivity by DES was 75%, whereas the specificity was 96%. The diagnostic accuracy by DES was significantly superior (({kappa}= 0.60, AUC = 0.909) to that by conventional technique ({kappa}= 0.18, AUC = 0.852) (p = 0.038). Dual energy subtraction is a superior method compared to the conventional FPD radiography for delineating the vocal cord and accurately diagnosing vocal cord paralysis.

  18. Standard practice for radiologic examination of flat panel composites and sandwich core materials used in aerospace applications

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This practice is intended to be used as a supplement to Practices E 1742, E 1255, and E 2033. 1.2 This practice describes procedures for radiologic examination of flat panel composites and sandwich core materials made entirely or in part from fiber-reinforced polymer matrix composites. Radiologic examination is: a) radiographic (RT) with film, b) Computed Radiography (CR) with Imaging Plate, c) Digital Radiology (DR) with Digital Detector Array’s (DDA), and d) Radioscopic (RTR) Real Time Radiology with a detection system such as an Image Intensifier. The composite materials under consideration typically contain continuous high modulus fibers (> 20 GPa), such as those listed in 1.4. 1.3 This practice describes established radiological examination methods that are currently used by industry that have demonstrated utility in quality assurance of flat panel composites and sandwich core materials during product process design and optimization, process control, after manufacture inspection, in service exami...

  19. A flat-panel detector based micro-CT system: performance evaluation for small-animal imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sang Chul; Kim, Ho Kyung; Chun, In Kon; Cho, Myung Hye; Lee, Soo Yeol; Cho, Min Hyoung [Graduate School of East-West Medical Science, Kyung Hee University, 1 Seochun, Kiheung, Yongin, Kyungki 449-701 (Korea, Republic of)

    2003-12-21

    A dedicated small-animal x-ray micro computed tomography (micro-CT) system has been developed to screen laboratory small animals such as mice and rats. The micro-CT system consists of an indirect-detection flat-panel x-ray detector with a field-of-view of 120 x 120 mm{sup 2}, a microfocus x-ray source, a rotational subject holder and a parallel data processing system. The flat-panel detector is based on a matrix-addressed photodiode array fabricated by a CMOS (complementary metal-oxide semiconductor) process coupled to a CsI:Tl (thallium-doped caesium iodide) scintillator as an x-ray-to-light converter. Principal imaging performances of the micro-CT system have been evaluated in terms of image uniformity, voxel noise and spatial resolution. It has been found that the image non-uniformity mainly comes from the structural non-uniform sensitivity pattern of the flat-panel detector and the voxel noise is about 48 CT numbers at the voxel size of 100 x 100 x 200 {mu}m{sup 3} and the air kerma of 286 mGy. When the magnification ratio is 2, the spatial resolution of the micro-CT system is about 14 lp/mm (line pairs per millimetre) that is almost determined by the flat-panel detector showing about 7 lp/mm resolving power. Through low-contrast phantom imaging studies, the minimum resolvable contrast has been found to be less than 36 CT numbers at the air kerma of 95 mGy. Some laboratory rat imaging results are presented.

  20. A flat-panel detector based micro-CT system: performance evaluation for small-animal imaging.

    Science.gov (United States)

    Lee, Sang Chul; Kim, Ho Kyung; Chun, In Kon; Cho, Myung Hye; Lee, Soo Yeol; Cho, Min Hyoung

    2003-12-21

    A dedicated small-animal x-ray micro computed tomography (micro-CT) system has been developed to screen laboratory small animals such as mice and rats. The micro-CT system consists of an indirect-detection flat-panel x-ray detector with a field-of-view of 120 x 120 mm2, a microfocus x-ray source, a rotational subject holder and a parallel data processing system. The flat-panel detector is based on a matrix-addressed photodiode array fabricated by a CMOS (complementary metal-oxide semiconductor) process coupled to a CsI:T1 (thallium-doped caesium iodide) scintillator as an x-ray-to-light converter. Principal imaging performances of the micro-CT system have been evaluated in terms of image uniformity, voxel noise and spatial resolution. It has been found that the image non-uniformity mainly comes from the structural non-uniform sensitivity pattern of the flat-panel detector and the voxel noise is about 48 CT numbers at the voxel size of 100 x 100 x 200 microm3 and the air kerma of 286 mGy. When the magnification ratio is 2, the spatial resolution of the micro-CT system is about 14 1p/mm (line pairs per millimetre) that is almost determined by the flat-panel detector showing about 7 1p/mm resolving power. Through low-contrast phantom imaging studies, the minimum resolvable contrast has been found to be less than 36 CT numbers at the air kerma of 95 mGy. Some laboratory rat imaging results are presented.

  1. Assessment of the CO2 fixation capacity of Anabaena sp. ATCC 33047 outdoor cultures in vertical flat-panel reactors.

    Science.gov (United States)

    Clares, Marta E; Moreno, José; Guerrero, Miguel G; García-González, Mercedes

    2014-10-10

    The extent of biological CO2 fixation was evaluated for outdoor cultures of the cyanobacterium Anabaena sp. ATCC 33047. Culture conditions were optimized indoors in bubble-column photochemostats operating in continuous mode, subjected to irradiance cycles mimicking the light regime outdoors. Highest values achieved for CO2 fixation rate and biomass productivity were 1 and 0.6 g L(-1) day(-1), respectively. The comparison among different reactors operating simultaneously - open pond, horizontal tubular reactor and vertical flat-panel - allowed to assess their relative efficiency for the outdoor development of Anabaena cultures. Despite the higher volumetric CO2 fixation capacity (and biomass productivity) exhibited by the tubular photobioreactor, yield of the flat-panel reactor was 50% higher than that of the tubular option on a per area basis, reaching values over 35 g CO2 fixed m(-2) d(-1). The flat-panel reactor actually represents a most suitable system for CO2 capture coupled to the generation of valuable biomass by Anabaena cultures.

  2. Reducing dose in urography while maintaining image quality - a comparison of storage phosphor plates and a flat-panel detector

    Energy Technology Data Exchange (ETDEWEB)

    Jansson, Margareta; Geijer, Haakan; Andersson, Torbjoern [Oerebro University Hospital, Department of Radiology, Oerebro (Sweden); Persliden, Jan [Oerebro University Hospital, Department of Medical Physics, Oerebro (Sweden); Linkoeping University, Department of Medicine and Care, Faculty of Health Sciences, Linkoeping (Sweden)

    2006-01-01

    The introduction of new flat-panel detector technology often forces us to accept too high dose levels as proposed by the manufacturers. We need a tool to compare the image quality of a new system with the accepted standard. The aim of this study was to obtain a comparable image quality for two systems - storage phosphor plates and a flat-panel system using intravenous urography (IVU) as a clinical model. The image quality figure was calculated using a contrast-detail phantom (CDRAD) for the two evaluated systems. This allowed us to set a dose for the flat-panel system that gave equivalent image quality to the storage phosphor plates. This reduced detector dose was used in an evaluation of clinical images to find out if the dose reduction from the phantom study indeed resulted in images of equal clinical image quality. The image quality was assessed using image criteria of the European guidelines for IVU with visual grading analysis. Equivalent image quality in image pairs was achieved at 30% of the dose. The CDRAD contrast-detail phantom makes it possible to find dose levels that give equal image quality using different imaging systems. (orig.)

  3. Parameter investigation and first results from a digital flat panel detector with forward bias capability

    Science.gov (United States)

    Starman, Jared; Tognina, Carlo; Virshup, Gary; Star-lack, Josh; Mollov, Ivan; Fahrig, Rebecca

    2008-03-01

    Digital flat panel a-Si x-ray detectors can exhibit image lag of several percent. The image lag can limit the temporal resolution of the detector, and introduce artifacts into CT reconstructions. It is believed that the majority of image lag is due to defect states, or traps, in the a-Si layer. Software methods to characterize and correct for the image lag exist, but they may make assumptions such as the system behaves in a linear time-invariant manner. The proposed method of reducing lag is a hardware solution that makes few additional hardware changes. For pulsed irradiation, the proposed method inserts a new stage in between the readout of the detector and the data collection stages. During this stage the photodiode is operated in a forward bias mode, which fills the defect states with charge. Parameters of importance are current per diode and current duration, which were investigated under light illumination by the following design parameters: 1.) forward bias voltage across the photodiode and TFT switch, 2.) number of rows simultaneously forward biased, and 3.) duration of the forward bias current. From measurements, it appears that good design criteria for the particular imager used are 8 or fewer active rows, 2.9V (or greater) forward bias voltage, and a row frequency of 100 kHz or less. Overall, the forward bias method has been found to reduce first frame lag by as much as 95%. The panel was also tested under x-ray irradiation. Image lag improved (94% reduction), but the temporal response of the scintillator became evident in the turn-on step response.

  4. The effect of discontinuous airlift mixing in outdoor flat panel photobioreactors on growth of Scenedesmus obliquus.

    Science.gov (United States)

    Leupold, Marco; Hindersin, Stefan; Kerner, Martin; Hanelt, Dieter

    2013-11-01

    Discontinuous airlift mixing was realized by injecting pressured air at time intervals with a frequency between 0.033 and 0.25 Hz (at 80 kPa; i.e., every 4-30 s; valve opening time 800 ms) into outdoor flat panel photobioreactors ([Formula: see text]). This caused a flow velocity between 2 and 20 cm s(-1) of the culture medium within the photobioreactor and the mixing time was between 38 and 103.5 s, requiring 0.175-1.340 L(gas volume) L(photobioreactor volume)(-1) min(-1) pressured air. In order to detect the effect on growth of Scenedesmus obliquus during outdoor experiments and to be able to compare obtained results, a batch run with an airlift frequency of 0.25 Hz was simultaneously used as control. Growth at different airlift frequencies was measured by the increase of cell dry weight (CDW) during 3-5 days and biomass yield on light energy was calculated. With increasing airlift frequencies, growth increased from 52 to 91 % compared to the control. When CDW was at around 1.0-1.5 g L(-1), airlift frequency had no effect on growth, indicating that mass transfer gradients of nutrients and gas were not the limiting factors of growth. Above 1.5 g CDW L(-1), growth increased with increasing airlift frequency and light limitation for a single cell occurred. This effect was observed during low and high irradiance and it is concluded that a higher mean flow causes a better light distribution, resulting in an enhanced growth. Biomass productivity and demand of pressured air are correlated logarithmically, which enables to save mixing energy during cultivation.

  5. Performance Study of an aSi Flat Panel Detector for Fast Neutron Imaging of Nuclear Waste

    Energy Technology Data Exchange (ETDEWEB)

    Schumann, M.; Mauerhofer, E. [Institute of Energy and Climate Research - Nuclear Waste Management and Reactor Safety, Forschungszentrum Juelich GmbH, 52425 Juelich (Germany); Engels, R.; Kemmerling, G. [Central Institute for Engineering, Electronics and Analytics - Electronic Systems, Forschungszentrum Juelich GmbH, 52425 Juelich (Germany); Frank, M. [MATHCCES - Department of Mathematics, RWTH Aachen University, 52062 Aachen (Germany); Havenith, A.; Kettler, J.; Klapdor-Kleingrothaus, T. [Institute of Nuclear Engineering and Technology Transfer, RWTH Aachen University, 52062 Aachen (Germany); Schitthelm, O. [Corporate Technology, Siemens AG, 91058 Erlangen (Germany)

    2015-07-01

    Radioactive waste must be characterized to check its conformance for intermediate storage and final disposal according to national regulations. For the determination of radio-toxic and chemo-toxic contents of radioactive waste packages non-destructive analytical techniques are preferentially used. Fast neutron imaging is a promising technique to assay large and dense items providing, in complementarity to photon imaging, additional information on the presence of structures in radioactive waste packages. Therefore the feasibility of a compact Neutron Imaging System for Radioactive waste Analysis (NISRA) using 14 MeV neutrons is studied in a cooperation framework of Forschungszentrum Juelich GmbH, RWTH Aachen University and Siemens AG. However due to the low neutron emission of neutron generators in comparison to research reactors the challenging task resides in the development of an imaging detector with a high efficiency, a low sensitivity to gamma radiation and a resolution sufficient for the purpose. The setup is composed of a commercial D-T neutron generator (Genie16GT, Sodern) with a surrounding shielding made of polyethylene, which acts as a collimator and an amorphous silicon flat panel detector (aSi, 40 x 40 cm{sup 2}, XRD-1642, Perkin Elmer). Neutron detection is achieved using a general propose plastic scintillator (EJ-260, Eljen Technology) linked to the detector. The thermal noise of the photodiodes is reduced by employing an entrance window made of aluminium. Optimal gain and integration time for data acquisition are set by measuring the response of the detector to the radiation of a 500 MBq {sup 241}Am-source. Detector performance was studied by recording neutron radiography images of materials with various, but well known, chemical compositions, densities and dimensions (Al, C, Fe, Pb, W, concrete, polyethylene, 5 x 8 x 10 cm{sup 3}). To simulate gamma-ray emitting waste radiographs in presence of a gamma-ray sources ({sup 60}Co, {sup 137}Cs, {sup 241

  6. Impact and Penetration of Thin Aluminum 2024 Flat Panels at Oblique Angles of Incidence

    Science.gov (United States)

    Ruggeri, Charles R.; Revilock, Duane M.; Pereira, J. Michael; Emmerling, William; Queitzsch, Gilbert K., Jr.

    2015-01-01

    under more extreme conditions, using a projectile with a more complex shape and sharp contacts, impacting flat panels at oblique angles of incidence.

  7. An investigation of flat panel equipment variables on image quality with a dedicated cardiac phantom

    Science.gov (United States)

    Dragusin, O.; Bosmans, H.; Pappas, C.; Desmet, W.

    2008-09-01

    Image quality (IQ) evaluation plays a key role in the process of optimization of new x-ray systems. Ideally, this process should be supported by real clinical images, but ethical issues and differences in anatomy and pathology of patients make it impossible. Phantom studies might overcome these issues. This paper presents the IQ evaluation of 30 cineangiographic films acquired with a cardiac flat panel system. The phantom used simulates the anatomy of the heart and allows the circulation of contrast agent boluses through coronary arteries. Variables investigated with influence on IQ and radiation dose are: tube potential, detector dose, added Copper filters, dynamic density optimization (DDO) and viewing angle. The IQ evaluation consisted of scoring 4 simulated calcified lesions located on different coronary artery segments in terms of degree of visualization. Eight cardiologists rated the lesions using a five-point scale ((1) lesion not visible to (5) very good visibility). Radiation doses associated to the angiograms are expressed in terms of incident air kerma (IAK) and effective dose that has been calculated with PCXMX software (STUK, Finland) from the exposure settings assuming a standard sized patient of 70 Kg. Mean IQ scores ranged from 1.68 to 4.88. The highest IQ scores were obtained for the angiograms acquired with tube potential 80 kVp, no added Cu filters, DDO 60%, RAO and LAO views and the highest entrance detector dose that has been used in the present study, namely 0.17 μGy/im. Radiation doses (IAK ~40 mGy and effective dose of 1 mSv) were estimated for angiograms acquired at 15 frames s-1, detector field-of-view 20 cm, and a length of 5 s. The following parameters improved the IQ factor significantly: a change in tube potential from 96 to 80 kVp, detector dose from 0.10 μGy/im to 0.17 μGy/im, the absence of Copper filtration. DDO variable which is a post-processing parameter should be carefully evaluated because it alters the quality of the

  8. Measurement of joint kinematics using a conventional clinical single-perspective flat-panel radiography system

    Energy Technology Data Exchange (ETDEWEB)

    Seslija, Petar; Teeter, Matthew G.; Yuan Xunhua; Naudie, Douglas D. R.; Bourne, Robert B.; MacDonald, Steven J.; Peters, Terry M.; Holdsworth, David W. [Biomedical Engineering Graduate Program, University of Western Ontario, London, Ontario N6A 5B9 (Canada) and Imaging Research Laboratories, Robarts Research Institute, London, Ontario N6A 5K8 (Canada); Department of Medical Biophysics, University of Western Ontario, London, Ontario N6A 5C1 (Canada) and Imaging Research Laboratories, Robarts Research Institute, London, Ontario N6A 5K8 (Canada); Imaging Research Laboratories, Robarts Research Institute, London, Ontario N6A 5K8 (Canada) and Division of Orthopaedic Surgery, University of Western Ontario and London Health Sciences Centre, London, Ontario N6A 4L6 (Canada); Division of Orthopaedic Surgery, University of Western Ontario and London Health Sciences Centre, London, Ontario N6A 4L6 (Canada); Biomedical Engineering Graduate Program, University of Western Ontario, London, Ontario N6A 5B9 (Canada); Department of Medical Biophysics, University of Western Ontario, London, Ontario N6A 5C1 (Canada) and Imaging Research Laboratories, Robarts Research Institute, London, Ontario N6A 5K8 (Canada)

    2012-10-15

    Purpose: The ability to accurately measure joint kinematics is an important tool in studying both normal joint function and pathologies associated with injury and disease. The purpose of this study is to evaluate the efficacy, accuracy, precision, and clinical safety of measuring 3D joint motion using a conventional flat-panel radiography system prior to its application in an in vivo study. Methods: An automated, image-based tracking algorithm was implemented to measure the three-dimensional pose of a sparse object from a two-dimensional radiographic projection. The algorithm was tested to determine its efficiency and failure rate, defined as the number of image frames where automated tracking failed, or required user intervention. The accuracy and precision of measuring three-dimensional motion were assessed using a robotic controlled, tibiofemoral knee phantom programmed to mimic a subject with a total knee replacement performing a stair ascent activity. Accuracy was assessed by comparing the measurements of the single-plane radiographic tracking technique to those of an optical tracking system, and quantified by the measurement discrepancy between the two systems using the Bland-Altman technique. Precision was assessed through a series of repeated measurements of the tibiofemoral kinematics, and was quantified using the across-trial deviations of the repeated kinematic measurements. The safety of the imaging procedure was assessed by measuring the effective dose of ionizing radiation associated with the x-ray exposures, and analyzing its relative risk to a human subject. Results: The automated tracking algorithm displayed a failure rate of 2% and achieved an average computational throughput of 8 image frames/s. Mean differences between the radiographic and optical measurements for translations and rotations were less than 0.08 mm and 0.07 Degree-Sign in-plane, and 0.24 mm and 0.6 Degree-Sign out-of-plane. The repeatability of kinematics measurements performed

  9. Response of a CsI/amorphous-Si flat panel detector as function of incident x-ray angle

    Science.gov (United States)

    Tkaczyk, J. Eric; Claus, Bernhard; Trotter, Dinko Gonzalez; Eberhard, J. W.

    2006-03-01

    Two mechanisms for MTF dependence on incident x-ray angle are demonstrated by an experimental technique that separates the two phenomena. The dominant effect is that travel of x-ray photons through the scintillator at non-normal incidence involves an in-plane component. This mechanism leads to a significant but deterministic blurring of the incident image, but has no effect on the noise transfer characteristics of the detector. A secondary effect is that at large angles to the surface normal, x-ray-to-optical conversion occurs at positions in the scintillator further away from the photodiode surface. This leads to a small net decrease in MTF and NPS at angles above 60 degrees. The deterministic character of the angular dependence of gain, MTF and NPS leads to the conclusion that sufficient angular range can be supported by this detector construction. Excellent functionality in the context of tomography is expected.

  10. Calibration model of a dual gain flat panel detector for 2D and 3D x-ray imaging.

    Science.gov (United States)

    Schmidgunst, C; Ritter, D; Lang, E

    2007-09-01

    The continuing research and further development in flat panel detector technology have led to its integration into more and more medical x-ray systems for two-dimensional (2D) and three-dimensional (3D) imaging, such as fixed or mobile C arms. Besides the obvious advantages of flat panel detectors, like the slim design and the resulting optimum accessibility to the patient, their success is primarily a product of the image quality that can be achieved. The benefits in the physical and performance-related features as opposed to conventional image intensifier systems, (e.g., distortion-free reproduction of imaging information or almost linear signal response over a large dynamic range) can be fully exploited, however, only if the raw detector images are correctly calibrated and postprocessed. Previous procedures for processing raw data contain idealizations that, in the real world, lead to artifacts or losses in image quality. Thus, for example, temperature dependencies or changes in beam geometry, as can occur with mobile C arm systems, have not been taken into account up to this time. Additionally, adverse characteristics such as image lag or aging effects have to be compensated to attain the best possible image quality. In this article a procedure is presented that takes into account the important dependencies of the individual pixel sensitivity of flat panel detectors used in 2D or 3D imaging and simultaneously minimizes the work required for an extensive recalibration. It is suitable for conventional detectors with only one gain mode as well as for the detectors specially developed for 3D imaging with dual gain read-out technology.

  11. Monte Carlo calculation of the spatial response (Modulated Transfer Function) of a scintillation flat panel and comparison with experimental results

    Science.gov (United States)

    Juste, Belén; Miró, Rafael; Monasor, Paula; Verdú, Gumersindo

    2015-11-01

    Phosphor screens are commonly used in many X-ray imaging applications. The design and optimization of these detectors can be achieved using Monte Carlo codes to simulate radiation transport in scintillation materials and to improve the spatial response. This work presents an exhaustive procedure to measure the spatial resolution of a scintillation flat panel image and to evaluate the agreement with data obtained by simulation. To evaluate the spatial response we have used the Modulated Transfer Function (MTF) parameter. According to this, we have obtained the Line Spread Function (LSF) of the system since the Fourier Transform (FT) of the LSF gives the MTF. The experimental images were carried out using a medical X-ray tube (Toshiba E7299X) and a flat panel (Hammamatsu C9312SK). Measurements were based on the slit methodology experimental implementation, which measures the response of the system to a line. LSF measurements have been performed using a 0.2 mm wide lead slit superimposed over the flat panel. The detector screen was modelled with MCNP (version 6) Monte Carlo simulation code in order to analyze the effect of the acquisition setup configuration and to compare the response of scintillator screens with the experimental results. MCNP6 offers the possibility of studying the optical physics parameters (optical scattering and absorption coefficients) that occur in the phosphor screen. The study has been tested for different X-ray tube voltages, from 100 to 140 kV. An acceptable convergence between the MTF results obtained with MCNP6 and the experimental measurements have been obtained.

  12. Volumetric soft tissue brain imaging on xCAT, a mobile flat-panel x-ray CT system

    Science.gov (United States)

    Zbijewski, Wojciech; Stayman, J. Webster

    2009-02-01

    We discuss the ongoing development of soft-tissue imaging capabilities on xCAT, a highly portable, flat-panel based cone-beam X-ray CT platform. By providing the ability to rapidly detect intra-cranial bleeds and other symptoms of stroke directly at the patient's bedside, our new system can potentially significantly improve the management of neurological emergency and intensive care patients. The paper reports on the design of our system, as well as on the methods used to combat artifacts due to scatter, non-linear detector response and scintillator glare. Images of cadaveric head samples are also presented and compared with conventional CT scans.

  13. Radiation dose reduction using a CdZnTe-based computed tomography system: Comparison to flat-panel detectors

    Energy Technology Data Exchange (ETDEWEB)

    Le, Huy Q.; Ducote, Justin L.; Molloi, Sabee [Department of Radiological Sciences, University of California, Irvine, California 92697 (United States)

    2010-03-15

    Purpose: Although x-ray projection mammography has been very effective in early detection of breast cancer, its utility is reduced in the detection of small lesions that are occult or in dense breasts. One drawback is that the inherent superposition of parenchymal structures makes visualization of small lesions difficult. Breast computed tomography using flat-panel detectors has been developed to address this limitation by producing three-dimensional data while at the same time providing more comfort to the patients by eliminating breast compression. Flat panels are charge integrating detectors and therefore lack energy resolution capability. Recent advances in solid state semiconductor x-ray detector materials and associated electronics allow the investigation of x-ray imaging systems that use a photon counting and energy discriminating detector, which is the subject of this article. Methods: A small field-of-view computed tomography (CT) system that uses CdZnTe (CZT) photon counting detector was compared to one that uses a flat-panel detector for different imaging tasks in breast imaging. The benefits afforded by the CZT detector in the energy weighting modes were investigated. Two types of energy weighting methods were studied: Projection based and image based. Simulation and phantom studies were performed with a 2.5 cm polymethyl methacrylate (PMMA) cylinder filled with iodine and calcium contrast objects. Simulation was also performed on a 10 cm breast specimen. Results: The contrast-to-noise ratio improvements as compared to flat-panel detectors were 1.30 and 1.28 (projection based) and 1.35 and 1.25 (image based) for iodine over PMMA and hydroxylapatite over PMMA, respectively. Corresponding simulation values were 1.81 and 1.48 (projection based) and 1.85 and 1.48 (image based). Dose reductions using the CZT detector were 52.05% and 49.45% for iodine and hydroxyapatite imaging, respectively. Image-based weighting was also found to have the least beam

  14. Performance analysis of a CsI-based flat panel detector in a cone beam variable resolution x-ray system

    Science.gov (United States)

    Dahi, Bahram; Keyes, Gary S.; Rendon, David A.; DiBianca, Frank A.

    2007-03-01

    A new Cone-Beam CT (CBCT) system is introduced that uses the concept of Variable Resolution X-ray (VRX) detection, which has previously been demonstrated to significantly increase spatial resolution for small objects. An amorphous silicon Flat Panel Detector (FPD) with a CsI scintillator (PaxScan 2020, Varian, Salt Lake City, UT) is coupled with a micro-focus x-ray tube (35 - 80 kVp, 10 - 250 μA) to form a CBCT. The FPD is installed on a rotating arm that can be adjusted to any angle θ, called the VRX angle, between 90° and 0° with respect to the x-ray direction. A VRX angle of 90° for the detector corresponds to a conventional CBCT whereas a VRX angle of 30° means that the detector is tilted 90° - 30° = 60° from its perpendicular position. Tilting the FPD in this manner reduces both the line-spread function width and the sampling distance by a factor of sin(θ), thereby increasing detector spatial resolution proportionately. An in-house phantom is used to measure the MTF of the reconstructed CT images using different VRX angles. An increase by a factor of 1.67 +/- 0.007 is observed in the MTF cutoff frequency at 30° compared to 90° in images acquired at 75 kVp. Expected theoretical value for this case is 2.0. The new Cone-Beam Variable Resolution X-ray (CB-VRX) CT system is expected to significantly improve the images acquired from small objects - such as small animals - while exploiting the opportunities offered by a conventional CBCT.

  15. The design and imaging characteristics of dynamic, solid-state, flat-panel x-ray image detectors for digital fluoroscopy and fluorography.

    Science.gov (United States)

    Cowen, A R; Davies, A G; Sivananthan, M U

    2008-10-01

    Dynamic, flat-panel, solid-state, x-ray image detectors for use in digital fluoroscopy and fluorography emerged at the turn of the millennium. This new generation of dynamic detectors utilize a thin layer of x-ray absorptive material superimposed upon an electronic active matrix array fabricated in a film of hydrogenated amorphous silicon (a-Si:H). Dynamic solid-state detectors come in two basic designs, the indirect-conversion (x-ray scintillator based) and the direct-conversion (x-ray photoconductor based). This review explains the underlying principles and enabling technologies associated with these detector designs, and evaluates their physical imaging characteristics, comparing their performance against the long established x-ray image intensifier television (TV) system. Solid-state detectors afford a number of physical imaging benefits compared with the latter. These include zero geometrical distortion and vignetting, immunity from blooming at exposure highlights and negligible contrast loss (due to internal scatter). They also exhibit a wider dynamic range and maintain higher spatial resolution when imaging over larger fields of view. The detective quantum efficiency of indirect-conversion, dynamic, solid-state detectors is superior to that of both x-ray image intensifier TV systems and direct-conversion detectors. Dynamic solid-state detectors are playing a burgeoning role in fluoroscopy-guided diagnosis and intervention, leading to the displacement of x-ray image intensifier TV-based systems. Future trends in dynamic, solid-state, digital fluoroscopy detectors are also briefly considered. These include the growth in associated three-dimensional (3D) visualization techniques and potential improvements in dynamic detector design.

  16. Dynamic modeling of the microalgae cultivation phase for energy production in open raceway ponds and flat panel photobioreactors

    Directory of Open Access Journals (Sweden)

    Matteo eMarsullo

    2015-09-01

    Full Text Available A dynamic model of microalgae cultivation phase is presented in this work. Two cultivation technologies are taken into account: the open raceway pond and the flat panel photobioreactor. For each technology, the model is able to evaluate the microalgae areal and volumetric productivity and the energy production and consumption. Differently from the most common existing models in literature, which deal with a specific part of the overall cultivation process, the model presented here includes all physical and chemical quantities that mostly affect microalgae growth: the equation of the specific growth rate for the microalgae is influenced by CO2 and nutrients concentration in the water, light intensity, temperature of the water in the reactor and by the microalgae species being considered. All these input parameters can be tuned to obtain reliable predictions. A comparison with experimental data taken from the literature shows that the predictions are consistent, slightly overestimating the productivity in case of closed photobioreactor. The results obtained by the simulation runs are consistent with those found in literature, being the areal productivity for the open raceway pond between 50 and 70 t/(ha*year in Southern Spain (Sevilla and Brazil (Petrolina and between 250 and 350 t/(ha*year for the flat panel photobioreactor in the same locations.

  17. Use of personal digital assistants for retrieval of medical images and data on high-resolution flat panel displays.

    Science.gov (United States)

    Ratib, Osman; McCoy, J Michael; McGill, D Ric; Li, Minglin; Brown, Allen

    2003-01-01

    For its new acute care hospital, the University of California at Los Angeles is evaluating innovative technology involving high-resolution flat panel display devices configured as "network appliances" that can be wall mounted for use in the retrieval and display of medical images and data. Physicians and healthcare providers can log on with wireless handheld computers, which can serve as an identification device as well as a navigational tool for selecting patient records and data. These data are displayed and manipulated on the flat panel display without the need for a keyboard or mouse. A prototype was developed with commercially available image display software, which was modified to allow the remote control of software functions from a handheld device through an infrared communication port. The system also allows navigation through the patient data in a World Wide Web-based electronic patient record. This prototype illustrates the evolution of radiologic facilities toward "shareable" high-quality display devices that allow more convenient and cost-effective access to medical images and related data in complex clinical environments, resulting in a paradigm shift in data navigation and accessibility.

  18. ELA-beam shaping systems for flat panel display prepared by LTPS%用于平板显示 LTPS制备的 ELA光束整形系统

    Institute of Scientific and Technical Information of China (English)

    尹广玥; 游利兵; 方晓东

    2016-01-01

    介绍了多晶硅薄膜较非晶硅薄膜在平板显示领域的优势以及准分子激光晶化制备多晶硅膜的结晶过程。介绍了透镜阵列实现匀光的原理。阐述了典型的准分子激光退火线型光束整形系统的扩束、匀光、投影等结构。并介绍了连续横向固化技术在准分子激光制备低温多晶硅领域的应用。讨论了准分子激光退火光学系统的发展现状,指出了其在平板显示行业的重要意义。%The advantages to poly silicon film instead of amorphous silicon film in the field of flat panel display were introduced .Crystallization process of poly silicon film by using excimer laser crystallization system was studied .The principle of how lens array achieve the uniformity of output laser energy density was described .The structure of typical excimer laser annealing(ELA) line beam shaping system, which included beam expanding unit , beam energy homogenizing unit , projection unit and so on was focused on .Finally the application of sequential lateral solidification technology in the area of low temperature poly silicon ( LTPS ) using excimer laser nnealing was introduced .The status of ELA optical system was discussed and its significance in flat panel display industry was pointed out .

  19. Robot arm based flat panel CT-guided electromagnetic tracked spine interventions: phantom and animal model experiments

    Energy Technology Data Exchange (ETDEWEB)

    Penzkofer, Tobias; Isfort, Peter; Bruners, Philipp; Mahnken, Andreas H. [RWTH Aachen University, Applied Medical Engineering, Helmholtz-Institute Aachen, Aachen (Germany); RWTH Aachen University, Department of Diagnostic Radiology, Aachen University Hospital, Aachen (Germany); Wiemann, Christian; Guenther, Rolf W. [RWTH Aachen University, Department of Diagnostic Radiology, Aachen University Hospital, Aachen (Germany); Kyriakou, Yiannis; Kalender, Willi A. [Friedrich-Alexander University of Erlangen-Nuremberg, Institute for Medical Physics, Erlangen (Germany); Schmitz-Rode, Thomas [RWTH Aachen University, Applied Medical Engineering, Helmholtz-Institute Aachen, Aachen (Germany)

    2010-11-15

    To evaluate accuracy and procedure times of electromagnetic tracking (EMT) in a robotic arm mounted flat panel setting using phantom and animal cadaveric models. A robotic arm mounted flat panel (RMFP) was used in combination with EMT to perform anthropomorphic phantom (n = 90) and ex vivo pig based punctures (n = 120) of lumbar facet joints (FJ, n = 120) and intervertebral discs (IVD, n = 90). Procedure accuracies and times were assessed and evaluated. FJ punctures were carried out with a spatial accuracy of 0.8 {+-} 0.9 mm (phantom) and 0.6 {+-} 0.8 mm (ex vivo) respectively. While IVD punctures showed puncture deviations of 0.6 {+-} 1.2 mm (phantom) and 0.5 {+-} 0.6 mm (ex vivo), direct and angulated phantom based punctures had accuracies of 0.8 {+-} 0.9 mm and 1.0 {+-} 1.3 mm. Planning took longer for ex vivo IVD punctures compared to phantom model interventions (39.3 {+-} 17.3 s vs. 20.8 {+-} 5.0 s, p = 0.001) and for angulated vs. direct phantom FJ punctures (19.7 {+-} 5.1 s vs. 28.6 {+-} 7.8 s, p < 0.001). Puncture times were longer for ex vivo procedures when compared to phantom model procedures in both FJ (37.9 {+-} 9.0 s vs. 23.6 {+-} 7.2 s, p = 0.001) and IVD punctures (43.9 {+-} 16.1 s vs. 31.1 {+-} 6.4 s, p = 0.026). The combination of RMFP with EMT provides an accurate method of navigation for spinal interventions such as facet joint punctures and intervertebral disc punctures. (orig.)

  20. Performance quantification of a flat-panel imager in industrial mega-voltage X-ray imaging systems

    Science.gov (United States)

    Stritt, Carina; Plamondon, Mathieu; Hofmann, Jürgen; Flisch, Alexander; Sennhauser, Urs

    2017-03-01

    Active matrix flat-panel detectors have gained popularity amongst X-ray imaging systems due to their speed, resolution and high dynamic range. With appropriate shielding modern flat-panel imagers can even be used in high energy Computed Tomography (CT) systems of energies up to several mega-electronvolt (MeV). However, the performance of a digital detector is not independent of the rest of the radiographic system but depends on all other components of the system. Signal and noise transfer properties highly depend on all parameters of an imaging chain. This work focuses on quantifying the resolution capabilities and the noise in the signals of a MeV X-ray imaging system. The performance quantification is done by computing the modulation transfer function (MTF) using the standard edge method as well as the noise power spectrum (NPS) of the imaging system. We performed Monte Carlo (MC) simulations in order to understand the influence of scattered radiation on the measurements. A comparison of the horizontal and vertical MTF showed that the imaging behaviour of the detector is isotropic. Moreover, an additional investigation of the noise performance of the system showed that there is no measurable noise correlation present in the system. It was shown that the thickness of the edge device does not have a significant influence on the resulting system MTF. A rapid drop in the visibility could be observed resulting in a value of 1.2 line pairs per mm at 50% MTF. The visibility limit of line pair patterns was found to be at 2.3 line pairs per mm given by the 10% MTF value.

  1. Evaluation of imaging quality for flat-panel detector based low dose C-arm CT system

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Chang-Woo; Cha, Bo Kyung; Jeon, Sungchae; Huh, Young [Converged Medical Device Research Center, Advanced Medical Device Research Division, KERI, Gyeonggido 426-910 (Korea, Republic of)

    2015-07-01

    The image quality associated with the extent of the angle of gantry rotation, the number of projection views, and the dose of X-ray radiation was investigated in flat-panel detector (FPD) based C-arm cone-beam computed tomography (CBCT) system for medical applications. A prototype CBCT system for the projection acquisition used the X-ray tube (A-132, Varian inc.) having rhenium-tungsten molybdenum target and flat panel a-Si X-ray detector (PaxScan 4030CB, Varian inc.) having a 397 x 298 mm active area with 388 μm pixel pitch and 1024 x 768 pixels in 2 by 2 binning mode. The performance comparison of X-ray imaging quality was carried out using the Feldkamp, Davis, and Kress (FDK) reconstruction algorithm between different conditions of projection acquisition. In this work, head-and-dental (75 kVp/20 mA) and chest (90 kVp/25 mA) phantoms were used to evaluate the image quality. The 361 (30 fps x 12 s) projection data during 360 deg. gantry rotation with 1 deg. interval for the 3D reconstruction were acquired. Parke weighting function were applied to handle redundant data and improve the reconstructed image quality in a mobile C-arm system with limited rotation angles. The reconstructed 3D images were investigated for comparison of qualitative image quality in terms of scan protocols (projection views, rotation angles and exposure dose). Furthermore, the performance evaluation in image quality will be investigated regarding X-ray dose and limited projection data for a FPD based mobile C-arm CBCT system. (authors)

  2. Cone beam breast CT with a high pitch (75 μm), thick (500 μm) scintillator CMOS flat panel detector: Visibility of simulated microcalcifications

    OpenAIRE

    2013-01-01

    Purpose: To measure and investigate the improvement of microcalcification (MC) visibility in cone beam breast CT with a high pitch (75 μm), thick (500 μm) scintillator CMOS/CsI flat panel detector (Dexela 2923, Perkin Elmer).

  3. Implementation of a program of quality assurance of image in an imaging system of flat panel portal; Puesta en marcha de un programa de garantia de calidad de imagen en un sistema de imagen portal de panel plano

    Energy Technology Data Exchange (ETDEWEB)

    Gomez Barrado, A.; Sanchez Jimenez, E.; Benitez, J. A.; Sanchez-Reyes, A.

    2013-07-01

    (IGRT) image-guided radiation therapy is the one in which images are used to locate the area of treatment. Modern irradiation systems are equipped with different modalities for obtaining images, such as flat panel systems, systems conebeam, tomoimagen, etc. This paper describes the start-up and the experience of a quality assurance program based on a flat panel portal Imaging System. (Author)

  4. Edge-Spread Functions Expected for Several Changes in a Commercial Flat-Panel System

    Energy Technology Data Exchange (ETDEWEB)

    Schach von Wittenau, A E

    2002-02-25

    The Bldg. 239 radiography facility uses a 9 MeV bremsstrahlung linac and a commercially available fiat-panel detector system. Ref. [1] discusses the facility in detail. Ref. [1] furthermore discusses the imaging quality of the fiat-panel system, and identifies several sources of image blur for the system in question. The maim'' contributors to the imaging blur are radiation scattered from the front cover of the detector housing, radiation scattered from the back cover of the detector housing, and radiation scattered from the aluminum plate that supports the amorphous-Si detector within the detector housing. The manufacturer of one such fiat-panel system seems willing to modify one of their products as requested, if such modifications may be made easily. Easy modifications would include making the detector housing thinner, decreasing the sizes of air gaps inside tile detector system, etc. Removing the aluminum support plate is considered to be a difficult modification. This memo reports the results of a set of Monte Carlo simulations that were performed to predict the changes in imaging quality, compared to that of the current system, if the detector is modified as suggested above. In particular, the edge-spread function (ESF) was calculated for each modification. ESFs were calculated for three photon energies: 100 keV, 450 keV, and 3 MeV. The results suggest that thinning and moving tile front and back covers of the detector housing should result in improved image quality for all of the photon energies considered. Interestingly, the results also suggest that removing the aluminum support plate would improve tim imaging performance at 100 keV and 450 keV, but that removing the plate has no additional benefit for imaging with 3 MeV photons.

  5. Percutaneous Glycerol Rhizotomy for Trigeminal Neuralgia Using a Single-Plane, Flat Panel Detector Angiography System: Technical Note.

    Science.gov (United States)

    Arishima, Hidetaka; Kawajiri, Satoshi; Arai, Hiroshi; Higashino, Yoshifumi; Kodera, Toshiaki; Kikuta, Ken-Ichiro

    2016-05-15

    Percutaneous treatments for trigeminal neuralgia (TN) including glycerol rhizotomy (GR), radiofrequency thermocoagulation (RT), and balloon compression (BC) are effective for patients with medical comorbidities and risk factors of microvascular decompression (MVD). These procedures are usually performed under fluoroscopy. Surgeons advance the needle to the trigeminal plexus through the foramen ovale while observing landmarks of fluoroscopic images; however, it is sometimes difficult to appropriately place the needle tip in Meckel's cave. We present the technical details of percutaneous GR using a single-plane, flat panel detector angiography system to check the needle positioning. When the needle tip may be located near the trigeminal cistern, three-dimensional (3-D) bone images are taken with cone-beam computed tomography (CT). These images clearly show the position of the needle tip in Meckel's cave. If it is difficult to place it through the foramen ovale, surgeons perform cone beam CT to observe the actual position of the needle tip at the skull base. After confirming the positional relation between the needle tip and foramen ovale, surgeons can advance it in the precise direction. In 10 procedures, we could place the nerve-block needle in about 14.5 minutes on average without complications. We think that our method is simple and convenient for percutaneous treatments for TN, and it may be helpful for surgeons to perform such treatments.

  6. Evaluation of bone substitute materials: comparison of flat-panel based volume CT to conventional multidetector CT.

    Science.gov (United States)

    Sauerbier, Sebastian; Duttenhoefer, Fabian; Sachlos, Elefterios; Haberstroh, Jörg; Scheifele, Christian; Wrbas, Karl-Thomas; Voss, Pit Jacob; Veigel, Egle; Smedek, Jörg; Ganter, Philip; Tuna, Taskin; Gutwald, Ralf; Palmowski, Moritz

    2013-10-01

    Over the last decade tissue engineering has emerged as a key factor in bone regeneration within the field of cranio-maxillofacial surgery. Despite this in vivo analysis of tissue-engineered-constructs to monitor bone rehabilitation are difficult to conduct. Novel high-resolving flat-panel based volume CTs (fp-VCT) are increasingly used for imaging bone structures. This study compares the potential value of novel fp-VCT with conventional multidetector CT (MDCT) based on a sheep sinus floor elevation model. Calcium-hydroxyapatite reinforced collagen scaffolds were populated with autologous osteoblasts and implanted into sheep maxillary sinus. After 8, 16 and 24 weeks MDCT and fp-VCT scans were performed to investigate the volume of the augmented area; densities of cancellous and compact bone were assessed as comparative values. fp-VCT imaging resulted in higher spatial resolution, which was advantageous when separating closely related anatomical structures (i.e. trabecular and compact bone, biomaterials). Fp-VCT facilitated imaging of alterations occurring in test specimens over time. fp-VCTs therefore displayed high volume coverage, dynamic imaging potential and superior performance when investigating superfine bone structures and bone remodelling of biomaterials. Thus, fp-VCTs may be a suitable instrument for intraoperative imaging and future in vivo tissue-engineering studies.

  7. Morphologic Changes of Mammary Carcinomas in Mice over Time as Monitored by Flat-Panel Detector Volume Computed Tomography

    Directory of Open Access Journals (Sweden)

    Jeannine Missbach-Guentner

    2008-07-01

    Full Text Available Noninvasive methods are strongly needed to detect and quantify not only tumor growth in murine tumor models but also the development of vascularization and necrosis within tumors. This study investigates the use of a new imaging technique, flat-panel detector volume computed tomography (fpVCT, to monitor in vivo tumor progression and structural changes within tumors of two murine carcinoma models. After tumor cell inoculation, single fpVCT scans of the entire mice were performed at different time points. The acquired isotropic, high-resolution volume data sets enable an accurate real-time assessment and precise measurements of tumor volumes. Spreading of contrast agent-containing blood vessels around and within the tumors was clearly visible over time. Furthermore, fpVCT permits the identification of differences in the uptake of contrast media within tumors, thus delineating necrosis, tumor tissues, and blood vessels. Classification of tumor tissues based on the decomposition of the underlying mixture distribution of tissue-related Hounsfield units allowed the quantitative acquisition of necrotic tissues at each time point. Morphologic alterations of the tumor depicted by fpVCT were confirmed by histopathologic examination. Concluding, our data show that fpVCT may be highly suitable for the noninvasive evaluation of tumor responses to anticancer therapies during the course of the disease.

  8. Percutaneous Glycerol Rhizotomy for Trigeminal Neuralgia Using a Single-Plane, Flat Panel Detector Angiography System: Technical Note

    Science.gov (United States)

    ARISHIMA, Hidetaka; KAWAJIRI, Satoshi; ARAI, Hiroshi; HIGASHINO, Yoshifumi; KODERA, Toshiaki; KIKUTA, Ken-ichiro

    2016-01-01

    Percutaneous treatments for trigeminal neuralgia (TN) including glycerol rhizotomy (GR), radiofrequency thermocoagulation (RT), and balloon compression (BC) are effective for patients with medical comorbidities and risk factors of microvascular decompression (MVD). These procedures are usually performed under fluoroscopy. Surgeons advance the needle to the trigeminal plexus through the foramen ovale while observing landmarks of fluoroscopic images; however, it is sometimes difficult to appropriately place the needle tip in Meckel’s cave. We present the technical details of percutaneous GR using a single-plane, flat panel detector angiography system to check the needle positioning. When the needle tip may be located near the trigeminal cistern, three-dimensional (3-D) bone images are taken with cone-beam computed tomography (CT). These images clearly show the position of the needle tip in Meckel’s cave. If it is difficult to place it through the foramen ovale, surgeons perform cone beam CT to observe the actual position of the needle tip at the skull base. After confirming the positional relation between the needle tip and foramen ovale, surgeons can advance it in the precise direction. In 10 procedures, we could place the nerve-block needle in about 14.5 minutes on average without complications. We think that our method is simple and convenient for percutaneous treatments for TN, and it may be helpful for surgeons to perform such treatments. PMID:27041633

  9. High-resolution dynamic angiography using flat-panel volume CT: feasibility demonstration for neuro and lower limb vascular applications

    Energy Technology Data Exchange (ETDEWEB)

    Mehndiratta, Amit [Massachusetts General Hospital, Department of Radiology, Harvard Medical School, Boston, MA (United States); University of Oxford, Institute of Biomedical Engineering and Keble College, Oxford (United Kingdom); Indian Institute of Technology Delhi and All India Institute of Medical Science, Centre for Biomedical Engineering, New Delhi (India); Rabinov, James D. [Massachusetts General Hospital, Interventional Neuroradiology, Harvard Medical School, Boston, MA (United States); Grasruck, Michael [Siemens Medical Solutions, Forchheim (Germany); Liao, Eric C. [Massachusetts General Hospital, Department of Plastic and Reconstructive Surgery and Center for Regenerative Medicine, Harvard Medical School, Boston, MA (United States); Crandell, David [Spaulding Rehabilitation Hospital, Department of Physical Medicine and Rehabilitation, Harvard Medical School, Charlestown, MA (United States); Gupta, Rajiv [Massachusetts General Hospital, Department of Radiology, Harvard Medical School, Boston, MA (United States)

    2015-07-15

    This paper evaluates a prototype flat-panel volume CT (fpVCT) for dynamic in vivo imaging in a variety of neurovascular and lower limb applications. Dynamic CTA was performed on 12 patients (neuro = 8, lower limb = 4) using an fpVCT with 120 kVp, 50 mA, rotation time varying from 8 to 19 s, and field of view of 25 x 25 x 18 cm{sup 3}. Four-dimensional data sets (i.e. 3D images over time) were reconstructed and reviewed. Dynamic CTA demonstrated sufficient spatio-temporal resolution to elucidate first-pass and recirculation dynamics of contrast bolus through neurovasclar pathologies and phasic blood flow though lower-limb vasculature and grafts. The high spatial resolution of fpVCT resulted in reduced partial volume and metal beam-hardening artefacts. This facilitated assessment of vascular lumen in the presence of calcified plaque and evaluation of fractures, especially in the presence of fixation hardware. Evaluation of arteriovenous malformation using dynamic fpVCT angiography was of limited utility. Dynamic CTA using fpVCT can visualize time-varying phenomena in neuro and lower limb vascular applications and has sufficient diagnostic imaging quality to evaluate a number of pathologies affecting these regions. (orig.)

  10. Visualization of novel microstents in patients with unruptured intracranial aneurysms with contrast-enhanced flat panel detector CT

    Energy Technology Data Exchange (ETDEWEB)

    Poncyljusz, Wojciech, E-mail: wponcyl@poczta.onet.pl [Departament of Interventional Radiology, Pomeranian Medical University, Neurointerventional Cath Lab MSW Hospital, Al. Powst. Wielkopolskich 72, 70-111 Szczecin (Poland); Zwarzany, Łukasz, E-mail: zwarzany@gmail.com [Departament of Interventional Radiology, Pomeranian Medical University, Neurointerventional Cath Lab MSW Hospital, Al. Powst. Wielkopolskich 72, 70-111 Szczecin (Poland); Safranow, Krzysztof, E-mail: chrissaf@mp.pl [Department of Biochemistry and Chemistry, Pomeranian Medical University, Al. Powst. Wielkopolskich 72, 70-111 Szczecin (Poland)

    2015-07-15

    Highlights: • We examine the feasibility of FPDCT for visualizing intracranial microstents. • Stent deployment and its apposition to the vessel wall are easily assessable. • Coil streaking artifacts hamper the assessment of stent visibility. - Abstract: Objectives: The aim of our study was to evaluate the feasibility of contrast-enhanced flat panel detector CT (FPDCT) for visualizing the novel microstents implanted in patients with unruptured wide-necked intracranial aneurysms. Methods: Forty-four cases of patients who underwent stent assisted coiling at our department were retrospectively analyzed. In each case, FPDCT images were performed after stent and coils deployment and then assessed in the terms of stent struts and all radiopaque markers and tantalum strands visibility separately using a 3-grade scale (1 – inadequate, 2 – good, 3 – excellent). Results: Stent struts visibility was assessed to be inadequate for evaluation in all cases. All radiopaque markers and tantalum strands visibility was excellent in 61.4% and good in 38.6% of cases. We observed 4 (9.09%) cases of incomplete stent opening. Treated aneurysm size <10 mm was an independent predictor of excellent stent all radiopaque markers and tantalum strands visibility (ρ = 0.014). Conclusions: Contrast-enhanced FPDCT is feasible for visualizing stents implanted in patients with intracranial aneurysms as it gives precise visualization of the relationships between the stent tantalum strands and the vessel wall. Stents used in the treatment of aneurysms ≥10 mm in size are worse visualized because of the coil streaking artifacts.

  11. Development and evaluation of a digital radiography system using a large-area flat-panel detector

    Science.gov (United States)

    Suzuki, Katsumi; Ikeda, Shigeyuki; Ishikawa, Ken; Iinuma, Gen; Ogasawara, Satoshi; Moriyama, Noriyuki; Konno, Yasutaka

    2002-05-01

    A new DR system using a large-area flat panel detector (FPD) with a 40 by 30 cm active area and a 194 micrometers pixel pitch, has been developed to compare with a conventional image intensifier and charge-coupled device camera type DR system. After measuring basic characteristics of the new DR system such as signal-to-noise ratio, modulation transfer function, and detective quantum efficiency, we applied the FPD to a Gastro-Intestinal study with contrast media, and discussed its potential for clinical use with a medical doctor. In radiography mode, the new DR system with a large-are FPD has superior image quality compared with the conventional I.I.- CCD camera type DR system because of high SNR and DQE. In fluoroscopy mode, the SNR of the new DR system at the exposure range of over 2(mu) R/frame is similar with the conventional I.I.-CCD camera type DR system. As a result, we considered that new DR system with a large-area FPD could be applied to a clinical study replacing an I.I.-CCD camera type. In the evaluation using various clinical images taken with the new DR system by a medical doctor, the new DR system with a large-are FPD performed sufficiently for a GI study.

  12. Aging of imaging properties of a CMOS flat-panel detector for dental cone-beam computed tomography

    Science.gov (United States)

    Kim, D. W.; Han, J. C.; Yun, S.; Kim, H. K.

    2017-01-01

    We have experimentally investigated the long-term stability of imaging properties of a flat-panel detector in conditions used for dental x-ray imaging. The detector consists of a CsI:Tl layer and CMOS photodiode pixel arrays. Aging simulations were carried out using an 80-kVp x-ray beam at an air-kerma rate of approximately 5 mGy s-1 at the entrance surface of the detector with a total air kerma of up to 0.6 kGy. Dark and flood-field images were periodically obtained during irradiation, and the mean signal and noise levels were evaluated for each image. We also evaluated the modulation-transfer function (MTF), noise-power spectrum (NPS), and detective quantum efficiency (DQE). The aging simulation showed a decrease in both the signal and noise of the gain-offset-corrected images, but there was negligible change in the signal-to-noise performance as a function of the accumulated dose. The gain-offset correction for analyzing images resulted in negligible changes in MTF, NPS, and DQE results over the total dose. Continuous x-ray exposure to a detector can cause degradation in the physical performance factors such the detector sensitivity, but linear analysis of the gain-offset-corrected images can assure integrity of the imaging properties of a detector during its lifetime.

  13. Varied tube potential with constant effective dose at lumbar spine radiography using a flat-panel digital detector.

    Science.gov (United States)

    Geijer, Håkan; Persliden, Jan

    2005-01-01

    The purpose of the study was to evaluate the image quality at different tube potential (kV) settings using anteroposterior lumbar spine radiography as a model. An Alderson phantom was used with a flat-panel detector. The tube potential varied between 48 and 125 kV while the tube charge (mAs) was adjusted to keep an effective dose of 0.11 mSv. Image quality was assessed with a visual grading analysis and with a CDRAD contrast-detail phantom together with a computer program. The VGA showed inferior image quality for the higher kV settings, > or =96 kVwith similar results for the contrast-detail phantom. When keeping the effective dose fixed, it seems beneficial to reduce kV to get the best image quality despite the fact that the mAs is not as high as with automatic exposure. However, this cannot be done with automatic exposure, which is set for a constant detector dose.

  14. Cross Talk Study to the Single Photon Response of a Flat Panel PMT for the RICH Upgrade at LHCb

    CERN Multimedia

    Arnaboldi, C; Calvi, M; Fanchini, E; Gotti, C; Maino, M; Matteuzzi, C; Perego, D L; Pessina, G; Wang, J C

    2009-01-01

    The Ring Imaging CHerenkov, RICH, detector at LHCb is now readout by Hybrid Photon Detectors. In view of its upgrade a possible option is the adoption of the flat panel Photon Multipliers Tubes, PMT. An important issue for the good determination of the rings produced in the sensitive media is a negligible level of cross talk. We have experimentally studied the cross talk from the 64x64 pixels of the H9500 PMT from Hamamatsu. Results have shown that at the single photon signal level, as expected at LHCb, the statistics applied to the small number of electrons generated at the first dynode of the PMT chain leads to a cross talk mechanism that must be interpreted in term of the percentage of the number of induced signals rather than on the amplitude of the induced signals. The threshold to suppress cross talk must be increased to a significant fraction of the single photon signal for the worst case. The number of electrons generated at the first dynode is proportional to the biasing voltage. Measurements have sh...

  15. Clinical evaluation of digital angiographic system equipped with the Safire' flat-panel detector of a direct conversion type

    Energy Technology Data Exchange (ETDEWEB)

    Miura, Yoshiaki; Miura, Yusuke; Goto, Keiichi [Shimadzu Corporation, Medical Systems Division, Research and Development, Kyoto (JP)] [and others

    2003-06-01

    This report presents a report on clinical evaluation of our newly developed flat-panel X-ray detector of a direct conversion type, designed to provide images of a resolution higher than, or at least equal to, that ensured by X-ray photographic films, in clinical digital X-ray cinematography. This new detector was named 'Safire' the acronym of 'Shimadzu advanced flat imaging receptor', emphasizing its high technological level, such as the capability to ensure high quality of images. The clinical evaluation of Shimadzu DIGITEX Premier digital angiography system, equipped with this new flat-panel X-ray detector of a direct conversion type, has been started in March, 2003, at the Kokura Memorial Hospital in Kyushu, Japan. (author)

  16. DR静态平板去除错层伪影的研究%Research on Elimination of Truncation Artifacts with Digital Radiography Static Flat Panel

    Institute of Scientific and Technical Information of China (English)

    王克枢

    2016-01-01

    This paper researched the occasional truncation artifacts during the application of Shimadzu D-vision digital radiography (DR) photographic system. Through analysis of features of abnormal image and design features of the DR equipment, the research found out that truncation artifacts were directly caused by premature movement of the flat panel detector. Based on the finding, the research proposed a resolution plan in which a flat panel detector delay return control circuit was added. Clinical results showed that the flat panel detector delay return control circuit integrated with D-vision DR photographic system could eliminate truncation artifacts caused by flat panel detector motion and improve DR image quality without decreasing examination efficiency, which allowed the design to be used in the improvement of related equipments.%本文对岛津D-vision平板摄影透视系统偶发的图像错层伪影现象进行了研究,通过对异常图像和设备自身设计特点进行分析,发现曝光后平板的过早运动是导致图像伪影的直接原因,基于此提出了加配平板延时返回控制电路的解决方案。改进后结果表明,在平板摄影透视系统加装平板延时返回功能后,图像错层现象消失,DR摄影图像质量得到提升,且改进不会影响检查效率,可应用推广至相关设备的改进。

  17. Comparative study of two flat-panel x-ray detectors applied to small-animal imaging cone-beam micro-CT

    OpenAIRE

    2008-01-01

    Proceeding of: 2008 IEEE Nuclear Science Symposium Conference Record (NSS '08), Dresden, Germany, 19-25 Oct. 2008 This work compares two different X-ray flat-panel detectors for its use in high-speed, cone-beam CT applied to small-animal imaging. The main differences between these two devices are the scintillators and the achievable frame rate. Both devices have been tested in terms of system linearity, sensitivity, resolution, stability and noise properties, taking into account the dif...

  18. X-ray performance of a wafer-scale CMOS flat panel imager for applications in medical imaging and nondestructive testing

    Science.gov (United States)

    Cha, Bo Kyung; Jeon, Seongchae; Seo, Chang-Woo

    2016-09-01

    This paper presents a wafer-scale complementary metal-oxide semiconductor (CMOS)-based X-ray flat panel detector for medical imaging and nondestructive testing applications. In this study, our proposed X-ray CMOS flat panel imager has been fabricated by using a 0.35 μm 1-poly/4-metal CMOS process. The pixel size is 100 μm×100 μm and the pixel array format is 1200×1200 pixels, which provide a field-of-view (FOV) of 120mm×120 mm. The 14.3-bit extended counting analog-to digital converter (ADC) with built-in binning mode was used to reduce the area and simultaneously improve the image resolution. The different screens such as thallium-doped CsI (CsI:Tl) and terbium gadolinium oxysulfide (Gd2O2S:Tb) scintillators were used as conversion materials for X-rays to visible light photons. The X-ray imaging performance such as X-ray sensitivity as a function of X-ray exposure dose, spatial resolution, image lag and X-ray images of various objects were measured under practical medical and industrial application conditions. This paper results demonstrate that our prototype CMOS-based X-ray flat panel imager has the significant potential for medical imaging and non-destructive testing (NDT) applications with high-resolution and high speed rate.

  19. X-ray performance of a wafer-scale CMOS flat panel imager for applications in medical imaging and nondestructive testing

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Bo Kyung, E-mail: goldrain99@kaist.ac.kr [Advanced Medical Device Research Center, Korea Electrotechnology Research Institute, Ansan (Korea, Republic of); Jeon, Seongchae [Advanced Medical Device Research Center, Korea Electrotechnology Research Institute, Ansan (Korea, Republic of); Seo, Chang-Woo [Department of Radiological Science, Yonsei University, Gangwon-do 220-710 (Korea, Republic of)

    2016-09-21

    This paper presents a wafer-scale complementary metal-oxide semiconductor (CMOS)-based X-ray flat panel detector for medical imaging and nondestructive testing applications. In this study, our proposed X-ray CMOS flat panel imager has been fabricated by using a 0.35 µm 1-poly/4-metal CMOS process. The pixel size is 100 µm×100 µm and the pixel array format is 1200×1200 pixels, which provide a field-of-view (FOV) of 120mm×120 mm. The 14.3-bit extended counting analog-to digital converter (ADC) with built-in binning mode was used to reduce the area and simultaneously improve the image resolution. The different screens such as thallium-doped CsI (CsI:Tl) and terbium gadolinium oxysulfide (Gd{sub 2}O{sub 2}S:Tb) scintillators were used as conversion materials for X-rays to visible light photons. The X-ray imaging performance such as X-ray sensitivity as a function of X-ray exposure dose, spatial resolution, image lag and X-ray images of various objects were measured under practical medical and industrial application conditions. This paper results demonstrate that our prototype CMOS-based X-ray flat panel imager has the significant potential for medical imaging and non-destructive testing (NDT) applications with high-resolution and high speed rate.

  20. Reducing dose in urography while maintaining image quality-a comparison of storage phosphor plates and a flat-panel detector.

    Science.gov (United States)

    Jansson, Margareta; Geijer, Håkan; Persliden, Jan; Andersson, Torbjörn

    2006-01-01

    The introduction of new flat-panel detector technology often forces us to accept too high dose levels as proposed by the manufacturers. We need a tool to compare the image quality of a new system with the accepted standard. The aim of this study was to obtain a comparable image quality for two systems-storage phosphor plates and a flat-panel system using intravenous urography (IVU) as a clinical model. The image quality figure was calculated using a contrast-detail phantom (CDRAD) for the two evaluated systems. This allowed us to set a dose for the flat-panel system that gave equivalent image quality to the storage phosphor plates. This reduced detector dose was used in an evaluation of clinical images to find out if the dose reduction from the phantom study indeed resulted in images of equal clinical image quality. The image quality was assessed using image criteria of the European guidelines for IVU with visual grading analysis. Equivalent image quality in image pairs was achieved at 30% of the dose. The CDRAD contrast-detail phantom makes it possible to find dose levels that give equal image quality using different imaging systems.

  1. Cone-beam CT with a flat-panel detector: From image science to image-guided surgery

    Energy Technology Data Exchange (ETDEWEB)

    Siewerdsen, Jeffrey H., E-mail: jeff.siewerdsen@jhu.edu [Department of Biomedical Engineering, Johns Hopkins University, Traylor Building, Room 718, 720 Rutland Avenue, Baltimore, MD 21205 (United States)

    2011-08-21

    The development of large-area flat-panel X-ray detectors (FPDs) has spurred investigation in a spectrum of advanced medical imaging applications, including tomosynthesis and cone-beam CT (CBCT). Recent research has extended image quality metrics and theoretical models to such applications, providing a quantitative foundation for the assessment of imaging performance as well as a general framework for the design, optimization, and translation of such technologies to new applications. For example, cascaded systems models of the Fourier domain metrics, such as noise-equivalent quanta (NEQ), have been extended to these modalities to describe the propagation of signal and noise through the image acquisition and reconstruction chain and to quantify the factors that govern spatial resolution, image noise, and detectability. Moreover, such models have demonstrated basic agreement with human observer performance for a broad range of imaging conditions and imaging tasks. These developments in image science have formed a foundation for the knowledgeable development and translation of CBCT to new applications in image-guided interventions-for example, CBCT implemented on a mobile surgical C-arm for intraoperative 3D imaging. The ability to acquire high-quality 3D images on demand during surgical intervention overcomes conventional limitations of surgical guidance in the context of preoperative images alone. A prototype mobile C-arm developed in academic-industry partnership demonstrates CBCT with low radiation dose, sub-mm spatial resolution, and soft-tissue visibility potentially approaching that of diagnostic CT. Integration of the 3D imaging system with real-time tracking, deformable registration, endoscopic video, and 3D visualization offers a promising addition to the surgical arsenal in interventions ranging from head-and-neck/skull base surgery to spine, orthopaedic, thoracic, and abdominal surgeries. Cadaver studies show the potential for significant boosts in surgical

  2. Cone-beam CT with a flat-panel detector: From image science to image-guided surgery

    Science.gov (United States)

    Siewerdsen, Jeffrey H.

    2011-08-01

    The development of large-area flat-panel X-ray detectors (FPDs) has spurred investigation in a spectrum of advanced medical imaging applications, including tomosynthesis and cone-beam CT (CBCT). Recent research has extended image quality metrics and theoretical models to such applications, providing a quantitative foundation for the assessment of imaging performance as well as a general framework for the design, optimization, and translation of such technologies to new applications. For example, cascaded systems models of the Fourier domain metrics, such as noise-equivalent quanta (NEQ), have been extended to these modalities to describe the propagation of signal and noise through the image acquisition and reconstruction chain and to quantify the factors that govern spatial resolution, image noise, and detectability. Moreover, such models have demonstrated basic agreement with human observer performance for a broad range of imaging conditions and imaging tasks. These developments in image science have formed a foundation for the knowledgeable development and translation of CBCT to new applications in image-guided interventions—for example, CBCT implemented on a mobile surgical C-arm for intraoperative 3D imaging. The ability to acquire high-quality 3D images on demand during surgical intervention overcomes conventional limitations of surgical guidance in the context of preoperative images alone. A prototype mobile C-arm developed in academic-industry partnership demonstrates CBCT with low radiation dose, sub-mm spatial resolution, and soft-tissue visibility potentially approaching that of diagnostic CT. Integration of the 3D imaging system with real-time tracking, deformable registration, endoscopic video, and 3D visualization offers a promising addition to the surgical arsenal in interventions ranging from head-and-neck/skull base surgery to spine, orthopaedic, thoracic, and abdominal surgeries. Cadaver studies show the potential for significant boosts in

  3. SU-E-J-45: The Correlation Between CBCT Flat Panel Misalignment and 3D Image Guidance Accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Kenton, O; Valdes, G; Yin, L; Teo, B [The Hospital of the University of Pennsylvania, Philadelphia, PA (United States); Brousmiche, S; Wikler, D [Ion Beam Application, Louvain-la-neuve (Belgium)

    2015-06-15

    Purpose To simulate the impact of CBCT flat panel misalignment on the image quality, the calculated correction vectors in 3D image guided proton therapy and to determine if these calibration errors can be caught in our QA process. Methods The X-ray source and detector geometrical calibration (flexmap) file of the CBCT system in the AdaPTinsight software (IBA proton therapy) was edited to induce known changes in the rotational and translational calibrations of the imaging panel. Translations of up to ±10 mm in the x, y and z directions (see supplemental) and rotational errors of up to ±3° were induced. The calibration files were then used to reconstruct the CBCT image of a pancreatic patient and CatPhan phantom. Correction vectors were calculated for the patient using the software’s auto match system and compared to baseline values. The CatPhan CBCT images were used for quantitative evaluation of image quality for each type of induced error. Results Translations of 1 to 3 mm in the x and y calibration resulted in corresponding correction vector errors of equal magnitude. Similar 10mm shifts were seen in the y-direction; however, in the x-direction, the image quality was too degraded for a match. These translational errors can be identified through differences in isocenter from orthogonal kV images taken during routine QA. Errors in the z-direction had no effect on the correction vector and image quality.Rotations of the imaging panel calibration resulted in corresponding correction vector rotations of the patient images. These rotations also resulted in degraded image quality which can be identified through quantitative image quality metrics. Conclusion Misalignment of CBCT geometry can lead to incorrect translational and rotational patient correction vectors. These errors can be identified through QA of the imaging isocenter as compared to orthogonal images combined with monitoring of CBCT image quality.

  4. The line-noise-reduction for low dose x-ray fluoroscopy with the flat panel detector

    Science.gov (United States)

    Nakamura, Tadashi; Ikeda, Shigeyuki; Suzuki, Katsumi; Takenouchi, Shinobu

    2006-03-01

    A scintillator type Flat Panel Detector (FPD)1 has a good noise performance especially in Fluoroscopic images because of high DQE. Almost same dose as I.I. and CCD system is accepted in clinical use. According to the clinical study, the dose in fluoroscopy will be decreased if we can reduce the line noise coming from gate line of the Thin Film Transistor (TFT). The purpose of this study is to detect and reduce this line noise from the fluoroscopic images making it possible to perform a lower dose of fluoroscopy imaging. We detected the line noise by acquiring a dark image (without exposure) and then comparing the average of the line data along to the gate line to the neighborhood lines. We have applied this method to the dark area taken by the collimator of the Lucite phantom image and detected it. The detected line will be compensated by interpolation with neighborhood lines. The FPD of our system2 has a big detecting area (40cm x 30cm) and a zoom mode is selected in fluoroscopy because the doctor is watching an edge of the guide-wire and a contrast medium. The collimated area of the detector is displayed in a monitor after the zooming process and we can take a collimated dark area for detecting the line noise. As we applied this method to the dark image (1024pixels x 1024lines) including 54 lines with noise, we can improve 10% of SD. Visible line noise of chest phantom image was reduced with this method. It will help to lower the fluoroscopy dose.

  5. Novel Na(+) doped Alq3 hybrid materials for organic light-emitting diode (OLED) devices and flat panel displays.

    Science.gov (United States)

    Bhagat, S A; Borghate, S V; Kalyani, N Thejo; Dhoble, S J

    2015-05-01

    Pure and Na(+) -doped Alq3 complexes were synthesized by a simple precipitation method at room temperature, maintaining a stoichiometric ratio. These complexes were characterized by X-ray diffraction, Fourier transform infrared (FTIR), UV/Vis absorption and photoluminescence (PL) spectra. The X-ray diffractogram exhibits well-resolved peaks, revealing the crystalline nature of the synthesized complexes, FTIR confirms the molecular structure and the completion of quinoline ring formation in the metal complex. UV/Vis absorption and PL spectra of sodium-doped Alq3 complexes exhibit high emission intensity in comparison with Alq3 phosphor, proving that when doped in Alq3 , Na(+) enhances PL emission intensity. The excitation spectra of the synthesized complexes lie in the range 242-457 nm when weak shoulders are also considered. Because the sharp excitation peak falls in the blue region of visible radiation, the complexes can be employed for blue chip excitation. The emission wavelength of all the synthesized complexes lies in the bluish green/green region ranging between 485 and 531 nm. The intensity of the emission wavelength was found to be elevated when Na(+) is doped into Alq3 . Because both the excitation and emission wavelengths fall in the visible region of electromagnetic radiation, these phosphors can also be employed to improve the power conversion efficiency of photovoltaic cells by using the solar spectral conversion principle. Thus, the synthesized phosphors can be used as bluish green/green light-emitting phosphors for organic light-emitting diodes, flat panel displays, solid-state lighting technology - a step towards the desire to reduce energy consumption and generate pollution free light.

  6. Nonlinear statistical reconstruction for flat-panel cone-beam CT with blur and correlated noise models

    Science.gov (United States)

    Tilley, Steven; Siewerdsen, Jeffrey H.; Zbijewski, Wojciech; Stayman, J. Webster

    2016-03-01

    Flat-panel cone-beam CT (FP-CBCT) is a promising imaging modality, partly due to its potential for high spatial resolution reconstructions in relatively compact scanners. Despite this potential, FP-CBCT can face difficulty resolving important fine scale structures (e.g, trabecular details in dedicated extremities scanners and microcalcifications in dedicated CBCT mammography). Model-based methods offer one opportunity to improve high-resolution performance without any hardware changes. Previous work, based on a linearized forward model, demonstrated improved performance when both system blur and spatial correlations characteristics of FP-CBCT systems are modeled. Unfortunately, the linearized model relies on a staged processing approach that complicates tuning parameter selection and can limit the finest achievable spatial resolution. In this work, we present an alternative scheme that leverages a full nonlinear forward model with both system blur and spatially correlated noise. A likelihood-based objective function is derived from this forward model and we derive an iterative optimization algorithm for its solution. The proposed approach is evaluated in simulation studies using a digital extremities phantom and resolution-noise trade-offs are quantitatively evaluated. The correlated nonlinear model outperformed both the uncorrelated nonlinear model and the staged linearized technique with up to a 86% reduction in variance at matched spatial resolution. Additionally, the nonlinear models could achieve finer spatial resolution (correlated: 0.10 mm, uncorrelated: 0.11 mm) than the linear correlated model (0.15 mm), and traditional FDK (0.40 mm). This suggests the proposed nonlinear approach may be an important tool in improving performance for high-resolution clinical applications.

  7. Semi-automatic classification of skeletal morphology in genetically altered mice using flat-panel volume computed tomography.

    Directory of Open Access Journals (Sweden)

    Christian Dullin

    2007-07-01

    Full Text Available Rapid progress in exploring the human and mouse genome has resulted in the generation of a multitude of mouse models to study gene functions in their biological context. However, effective screening methods that allow rapid noninvasive phenotyping of transgenic and knockout mice are still lacking. To identify murine models with bone alterations in vivo, we used flat-panel volume computed tomography (fpVCT for high-resolution 3-D imaging and developed an algorithm with a computational intelligence system. First, we tested the accuracy and reliability of this approach by imaging discoidin domain receptor 2- (DDR2- deficient mice, which display distinct skull abnormalities as shown by comparative landmark-based analysis. High-contrast fpVCT data of the skull with 200 microm isotropic resolution and 8-s scan time allowed segmentation and computation of significant shape features as well as visualization of morphological differences. The application of a trained artificial neuronal network to these datasets permitted a semi-automatic and highly accurate phenotype classification of DDR2-deficient compared to C57BL/6 wild-type mice. Even heterozygous DDR2 mice with only subtle phenotypic alterations were correctly determined by fpVCT imaging and identified as a new class. In addition, we successfully applied the algorithm to classify knockout mice lacking the DDR1 gene with no apparent skull deformities. Thus, this new method seems to be a potential tool to identify novel mouse phenotypes with skull changes from transgenic and knockout mice on the basis of random mutagenesis as well as from genetic models. However for this purpose, new neuronal networks have to be created and trained. In summary, the combination of fpVCT images with artificial neuronal networks provides a reliable, novel method for rapid, cost-effective, and noninvasive primary screening tool to detect skeletal phenotypes in mice.

  8. Comparison of image quality and radiation dose between an image-intensifier system and a newer-generation flat-panel detector system - technical phantom measurements and evaluation of clinical imaging in children

    Energy Technology Data Exchange (ETDEWEB)

    Weis, Meike; Hagelstein, Claudia; Diehm, Theo; Schoenberg, Stefan O.; Neff, K.W. [University Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Institute of Clinical Radiology and Nuclear Medicine, Mannheim (Germany)

    2016-02-15

    Many image-intensifier fluoroscopy systems have been replaced by flat-panel detectors in recent years. To compare the level of contrast, image resolution and radiation dose between an image-intensifier and a newer-generation flat-panel detector system in a pediatric radiology unit. We compared two systems - a conventional image intensifier and a newer-generation flat-panel system. We measured image quality and radiation dose using a technical phantom. Additionally, we retrospectively compared age-matched fluoroscopic pediatric voiding cystourethrography (n = 15) and upper gastrointestinal investigations (n = 25). In phantom studies image contrast was equal while image resolution was higher and mean radiation dose lower using the flat-panel system (P < 0.0001). In pediatric investigations, mean dose area product was significantly reduced on the flat-panel system for upper gastrointestinal investigation (45 ± 38 μGy*m{sup 2} vs. 11 ± 9 μGy*m{sup 2}; P < 0.0001) and for voiding cystourethrography (18 ± 20 μGy*m{sup 2} vs. 10 ± 12 μGy*m{sup 2}; P = 0.04). The newer flat-panel system performs at lower dose levels with equal to better image quality and therefore seems to be the more suitable technique for pediatric fluoroscopy in comparison to image-intensifier systems. (orig.)

  9. A compact high resolution flat panel PET detector based on the new 4-side buttable MPPC for biomedical applications

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Qiang, E-mail: wangqiang@mir.wustl.edu [Washington University in St Louis, MO 63110 (United States); Wen, Jie; Ravindranath, Bosky; O' Sullivan, Andrew W. [Washington University in St Louis, MO 63110 (United States); Catherall, David [Saint Louis University, St. Louis, MO 63103 (United States); Li, Ke; Wei, Shouyi; Komarov, Sergey [Washington University in St Louis, MO 63110 (United States); Tai, Yuan-Chuan, E-mail: taiy@mir.wustl.edu [Washington University in St Louis, MO 63110 (United States)

    2015-09-11

    Compact high-resolution panel detectors using virtual pinhole (VP) PET geometry can be inserted into existing clinical or pre-clinical PET systems to improve regional spatial resolution and sensitivity. Here we describe a compact panel PET detector built using the new Though Silicon Via (TSV) multi-pixel photon counters (MPPC) detector. This insert provides high spatial resolution and good timing performance for multiple bio-medical applications. Because the TSV MPPC design eliminates wire bonding and has a package dimension which is very close to the MPPC's active area, it is 4-side buttable. The custom designed MPPC array (based on Hamamatsu S12641-PA-50(x)) used in the prototype is composed of 4×4 TSV-MPPC cells with a 4.46 mm pitch in both directions. The detector module has 16×16 lutetium yttrium oxyorthosilicate (LYSO) crystal array, with each crystal measuring 0.92×0.92×3 mm{sup 3} with 1.0 mm pitch. The outer diameter of the detector block is 16.8×16.8 mm{sup 2}. Thirty-two such blocks will be arranged in a 4×8 array with 1 mm gaps to form a panel detector with detection area around 7 cm×14 cm in the full-size detector. The flood histogram acquired with {sup 68}Ge source showed excellent crystal separation capability with all 256 crystals clearly resolved. The detector module's mean, standard deviation, minimum (best) and maximum (worst) energy resolution were 10.19%, ±0.68%, 8.36% and 13.45% FWHM, respectively. The measured coincidence time resolution between the block detector and a fast reference detector (around 200 ps single photon timing resolution) was 0.95 ns. When tested with Siemens Cardinal electronics the performance of the detector blocks remain consistent. These results demonstrate that the TSV-MPPC is a promising photon sensor for use in a flat panel PET insert composed of many high resolution compact detector modules.

  10. A compact high resolution flat panel PET detector based on the new 4-side buttable MPPC for biomedical applications

    Science.gov (United States)

    Wang, Qiang; Wen, Jie; Ravindranath, Bosky; O`Sullivan, Andrew W.; Catherall, David; Li, Ke; Wei, Shouyi; Komarov, Sergey; Tai, Yuan-Chuan

    2015-09-01

    Compact high-resolution panel detectors using virtual pinhole (VP) PET geometry can be inserted into existing clinical or pre-clinical PET systems to improve regional spatial resolution and sensitivity. Here we describe a compact panel PET detector built using the new Though Silicon Via (TSV) multi-pixel photon counters (MPPC) detector. This insert provides high spatial resolution and good timing performance for multiple bio-medical applications. Because the TSV MPPC design eliminates wire bonding and has a package dimension which is very close to the MPPC's active area, it is 4-side buttable. The custom designed MPPC array (based on Hamamatsu S12641-PA-50(x)) used in the prototype is composed of 4×4 TSV-MPPC cells with a 4.46 mm pitch in both directions. The detector module has 16×16 lutetium yttrium oxyorthosilicate (LYSO) crystal array, with each crystal measuring 0.92×0.92×3 mm3 with 1.0 mm pitch. The outer diameter of the detector block is 16.8×16.8 mm2. Thirty-two such blocks will be arranged in a 4×8 array with 1 mm gaps to form a panel detector with detection area around 7 cm×14 cm in the full-size detector. The flood histogram acquired with 68Ge source showed excellent crystal separation capability with all 256 crystals clearly resolved. The detector module's mean, standard deviation, minimum (best) and maximum (worst) energy resolution were 10.19%, ±0.68%, 8.36% and 13.45% FWHM, respectively. The measured coincidence time resolution between the block detector and a fast reference detector (around 200 ps single photon timing resolution) was 0.95 ns. When tested with Siemens Cardinal electronics the performance of the detector blocks remain consistent. These results demonstrate that the TSV-MPPC is a promising photon sensor for use in a flat panel PET insert composed of many high resolution compact detector modules.

  11. A compact high resolution flat panel PET detector based on the new 4-side buttable MPPC for biomedical applications

    Science.gov (United States)

    Wang, Qiang; Wen, Jie; Ravindranath, Bosky; O’Sullivan, Andrew W.; Catherall, David; Li, Ke; Wei, Shouyi; Komarov, Sergey; Tai, Yuan-Chuan

    2015-01-01

    Compact high-resolution panel detectors using virtual pinhole (VP) PET geometry can be inserted into existing clinical or pre-clinical PET systems to improve regional spatial resolution and sensitivity. Here we describe a compact panel PET detector built using the new Though Silicon Via (TSV) multi-pixel photon counters (MPPC) detector. This insert provides high spatial resolution and good timing performance for multiple bio-medical applications. Because the TSV MPPC design eliminates wire bonding and has a package dimension which is very close to the MPPC’s active area, it is 4-side buttable. The custom designed MPPC array (based on Hamamatsu S12641-PA-50(x)) used in the prototype is composed of 4 × 4 TSV-MPPC cells with a 4.46 mm pitch in both directions. The detector module has 16 × 16 lutetium yttrium oxyorthosilicate (LYSO) crystal array, with each crystal measuring 0.92 × 0.92 × 3 mm3 with 1.0 mm pitch. The outer diameter of the detector block is 16.8 × 16.8 mm2. Thirty-two such blocks will be arranged in a 4 × 8 array with 1 mm gaps to form a panel detector with detection area around 7 cm × 14 cm in the full-size detector. The flood histogram acquired with Ge-68 source showed excellent crystal separation capability with all 256 crystals clearly resolved. The detector module’s mean, standard deviation, minimum (best) and maximum (worst) energy resolution were 10.19%, +/−0.68%, 8.36% and 13.45% FWHM, respectively. The measured coincidence time resolution between the block detector and a fast reference detector (around 200 ps single photon timing resolution) was 0.95 ns. When tested with Siemens Cardinal electronics the performance of the detector blocks remain consistent. These results demonstrate that the TSV-MPPC is a promising photon sensor for use in a flat panel PET insert composed of many high resolution compact detector modules. PMID:26085702

  12. 激光切割平板夹具的改进%The improvement of laser cutting flat-panel clamp

    Institute of Scientific and Technical Information of China (English)

    王斌修; 贺敬地

    2011-01-01

    The paper designs a new type of cutting workmanship facility through analyzing domestic laser cutting flat -panel workmanship facility, and points out the shortcomings.The new workmanship facility can be disassembled so that it increases using efficiency greatly.%通过对国内激光平面切割工装的分析对比,指出了现有工装的缺点,设计了一套新型的切割工装.该工装可拆卸,极大地提高了使用效率.

  13. Dual-energy cone-beam CT with a flat-panel detector: Effect of reconstruction algorithm on material classification

    Energy Technology Data Exchange (ETDEWEB)

    Zbijewski, W., E-mail: wzbijewski@jhu.edu; Gang, G. J.; Xu, J.; Wang, A. S.; Stayman, J. W. [Department of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland 21205 (United States); Taguchi, K.; Carrino, J. A. [Russell H. Morgan Department of Radiology, Johns Hopkins University, Baltimore, Maryland 21205 (United States); Siewerdsen, J. H. [Department of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland 21205 and Russell H. Morgan Department of Radiology, Johns Hopkins University, Baltimore, Maryland 21205 (United States)

    2014-02-15

    Purpose: Cone-beam CT (CBCT) with a flat-panel detector (FPD) is finding application in areas such as breast and musculoskeletal imaging, where dual-energy (DE) capabilities offer potential benefit. The authors investigate the accuracy of material classification in DE CBCT using filtered backprojection (FBP) and penalized likelihood (PL) reconstruction and optimize contrast-enhanced DE CBCT of the joints as a function of dose, material concentration, and detail size. Methods: Phantoms consisting of a 15 cm diameter water cylinder with solid calcium inserts (50–200 mg/ml, 3–28.4 mm diameter) and solid iodine inserts (2–10 mg/ml, 3–28.4 mm diameter), as well as a cadaveric knee with intra-articular injection of iodine were imaged on a CBCT bench with a Varian 4343 FPD. The low energy (LE) beam was 70 kVp (+0.2 mm Cu), and the high energy (HE) beam was 120 kVp (+0.2 mm Cu, +0.5 mm Ag). Total dose (LE+HE) was varied from 3.1 to 15.6 mGy with equal dose allocation. Image-based DE classification involved a nearest distance classifier in the space of LE versus HE attenuation values. Recognizing the differences in noise between LE and HE beams, the LE and HE data were differentially filtered (in FBP) or regularized (in PL). Both a quadratic (PLQ) and a total-variation penalty (PLTV) were investigated for PL. The performance of DE CBCT material discrimination was quantified in terms of voxelwise specificity, sensitivity, and accuracy. Results: Noise in the HE image was primarily responsible for classification errors within the contrast inserts, whereas noise in the LE image mainly influenced classification in the surrounding water. For inserts of diameter 28.4 mm, DE CBCT reconstructions were optimized to maximize the total combined accuracy across the range of calcium and iodine concentrations, yielding values of ∼88% for FBP and PLQ, and ∼95% for PLTV at 3.1 mGy total dose, increasing to ∼95% for FBP and PLQ, and ∼98% for PLTV at 15.6 mGy total dose. For a

  14. WE-G-204-04: Focal Spot Deblurring For High Resolution Amorphous Selenium (aSe) Complementary Metal Oxide Semiconductor (CMOS) X-Ray Detector

    Energy Technology Data Exchange (ETDEWEB)

    Nagesh, S Setlur; Rana, R; Russ, M; Ionita, C; Bednarek, D; Rudin, S [Toshiba Stroke and Vascular Research Center, University at Buffalo, SUNY (United States)

    2015-06-15

    Purpose: CMOS-based aSe detectors compared to CsI-TFT-based flat panels have the advantages of higher spatial sampling due to smaller pixel size and decreased blurring characteristic of direct rather than indirect detection. For systems with such detectors, the limiting factor degrading image resolution then becomes the focal-spot geometric unsharpness. This effect can seriously limit the use of such detectors in areas such as cone beam computed tomography, clinical fluoroscopy and angiography. In this work a technique to remove the effect of focal-spot blur is presented for a simulated aSe detector. Method: To simulate images from an aSe detector affected with focal-spot blur, first a set of high-resolution images of a stent (FRED from Microvention, Inc.) were acquired using a 75µm pixel size Dexela-Perkin-Elmer detector and averaged to reduce quantum noise. Then the averaged image was blurred with a known Gaussian blur at two different magnifications to simulate an idealized focal spot. The blurred images were then deconvolved with a set of different Gaussian blurs to remove the effect of focal-spot blurring using a threshold-based, inverse-filtering method. Results: The blur was removed by deconvolving the images using a set of Gaussian functions for both magnifications. Selecting the correct function resulted in an image close to the original; however, selection of too wide a function would cause severe artifacts. Conclusion: Experimentally, focal-spot blur at different magnifications can be measured using a pin hole with a high resolution detector. This spread function can be used to deblur the input images that are acquired at corresponding magnifications to correct for the focal spot blur. For CBCT applications, the magnification of specific objects can be obtained using initial reconstructions then corrected for focal-spot blurring to improve resolution. Similarly, if object magnification can be determined such correction may be applied in fluoroscopy and

  15. An indirect flat-panel detector with avalanche gain for low dose x-ray imaging: SAPHIRE (scintillator avalanche photoconductor with high resolution emitter readout)

    Science.gov (United States)

    Zhao, Wei; Li, Dan; Rowlands, J. A.; Egami, N.; Takiguchi, Y.; Nanba, M.; Honda, Y.; Ohkawa, Y.; Kubota, M.; Tanioka, K.; Suzuki, K.; Kawai, T.

    2008-03-01

    An indirect flat-imager with programmable avalanche gain and field emitter array (FEA) readout is being investigated for low-dose x-ray imaging with high resolution. It is made by optically coupling a structured x-ray scintillator CsI (Tl) to an amorphous selenium (a-Se) avalanche photoconductor called HARP (high-gain avalanche rushing photoconductor). The charge image created by HARP is read out by electron beams generated by the FEA. The proposed detector is called SAPHIRE (Scintillator Avalanche Photoconductor with HIgh Resolution Emitter readout). The avalanche gain of HARP depends on both a-Se thickness and applied electric field E Se. At E Se of > 80 V/μm, the avalanche gain can enhance the signal at low dose (e.g. fluoroscopy) and make the detector x-ray quantum noise limited down to a single x-ray photon. At high exposure (e.g. radiography), the avalanche gain can be turned off by decreasing E Se to < 70 V/μm. In this paper the imaging characteristics of the FEA readout method, including the spatial resolution and noise, were investigated experimentally using a prototype optical HARP-FEA image sensor. The potential x-ray imaging performance of SAPHIRE, especially the aspect of programmable gain to ensure wide dynamic range and x-ray quantum noise limited performance at the lowest exposure in fluoroscopy, was investigated.

  16. Thermo-enhanced field emission from ZnO nanowires: Role of defects and application in a diode flat panel X-ray source

    Science.gov (United States)

    Zhang, Zhipeng; Chen, Daokun; Chen, Wenqing; Chen, Yicong; Song, Xiaomeng; Zhan, Runze; Deng, Shaozhi; Xu, Ningsheng; Chen, Jun

    2017-03-01

    A thermo-enhanced field emission phenomenon was observed from ZnO nanowires. The field emission current increased by almost two orders of magnitude under a constant applied electric field, and the turn-on field decreased from 6.04 MV/m to 5.0 MV/m when the temperature increased from 323 to 723 K. The Poole-Frenkel electron excitation from the defect-induced trapping centers to the conduction band under high electric fields is believed to be the primary cause of the observed phenomenon. The experimental results fit well with the proposed physical model. The field emission from ZnO nanowires with different defect concentrations further confirmed the role of defects. Using the thermo-enhanced field emission phenomenon, a diode flat panel X-ray source was demonstrated, for which the energy and dose can be separately tuned. The thermo-enhanced field emission phenomenon observed from ZnO nanowires could be an effective way to realize a large area flat panel multi-energy X-ray source.

  17. [Correlation between basic imaging properties and subjective evaluations of two digital radiographic X-ray systems based on direct-conversion flat panel detector].

    Science.gov (United States)

    Sakaguchi, Taro; Katayama, Reiji; Morishita, Junji; Sakai, Shinji; Kuroki, Hidefumi; Ohkubo, Seiji; Maeda, Takashi; Hayabuchi, Naofumi

    2010-11-20

    The purpose of this study was to examine the correlation between the basic imaging properties of two digital radiographic X-ray systems with a direct conversion flat-panel detector and their image qualities, which were evaluated by the observer in hard copy and soft copy studies. The subjective image quality was evaluated and compared in terms of the low-contrast detectability and image sharpness in the two digital radiographic X-ray systems. We applied the radiographs of a contrast detail phantom to the evaluation of low-contrast detectability and analyzed the contrast detail diagrams. Finally, low-contrast detectability was evaluated by the image quality figure (IQF) calculated from the contrast detail diagrams. Also, the subjective image sharpness of human dry bones of two systems was examined and evaluated by the normalized-rank method. The results indicated that System A tended to provide superior subjective image quality compared to System B in both observer studies. We also found high correlations between IQFs and basic imaging properties, such as the noise power spectrum (NPS) and the noise equivalent quantum (NEQ). In conclusion, the low-contrast detectability of the two digital radiographic X-ray systems with a direct conversion flat-panel detector corresponded to the NPS and the NEQ in both outputs (soft copy and hard copy). On the other hand, the subjective image sharpness of human dry bones was affected by their noise properties.

  18. Clinical application of flat-panel CT in the angio suite; Klinische Anwendung der Flachdetektor-CT im Angio-OP

    Energy Technology Data Exchange (ETDEWEB)

    Hausegger, K.A.; Fuerstner, M.; Hauser, M.; Smetana, F.; Kau, T. [Landeskrankenhaus Klagenfurt (Austria). Roentgendiagnostisches Zentralinstitut; Klinikum Klagenfurt (Austria). Inst. fuer Diagnostische und Interventionelle Radiologie

    2011-12-15

    The introduction of flat-panel detectors in modern angiographic C-arm systems makes it possible to acquire CT-like images in the angiographic suite (flat-panel CT; FD-CT). In this review, after a short technical introduction of FD-CT including the discussion of the advantages and disadvantages of this new imaging modality, the most commonly and best evaluated indications for FD-CT will be described. FD-CT has become an important adjunctive imaging modality in neurointerventional procedures and embolizations, especially during liver embolization. Another attractive indication for FD-CT is musculoskeletal interventions. FD-CT may provide important additional information in complicated peripheral vascular interventions and stent-graft procedures. FD-CT has a broad spectrum of possible applications, which finally depends on the experience and innovative thinking of the operator. However, it has to be kept in mind that FD-CT causes additional radiation exposure. Roughly, it can be assumed that currently one FD-CT sequence causes at least the same radiation exposure as one spiral CT sequence of the corresponding body region. (orig.)

  19. 数字平板探测器的原理及应用%Principle and Application of Flat Panel Detectors

    Institute of Scientific and Technical Information of China (English)

    王建华

    2011-01-01

    Digital radiographic testing is a hot research direction at present, in which the development process of the digital detector will determine the development direction of digital radiographic testing. The developing history, structure, imaging process, image quality and application advantages of digital flat panel detector were described. By the practical measurement, it was confirmed that flat-panel detector test was expected to replace traditional film imaging and image intensifier mode, and it showed a very broad application prospects.%数字射线检测是当前射线检测的热点研究方向,其中探测器的发展进程直接决定了数字射线检测的发展方向。介绍了目前应用较广的平板探测器的发展历史、平板结构、成像过程、成像质量以及应用优势等。通过实测试验,证实了平板探测器有望取代传统的胶片成像以及图像增强器方式成像,应用前景非常广阔。

  20. Theoretical and Monte Carlo optimization of a stacked three-layer flat-panel x-ray imager for applications in multi-spectral diagnostic medical imaging

    Science.gov (United States)

    Lopez Maurino, Sebastian; Badano, Aldo; Cunningham, Ian A.; Karim, Karim S.

    2016-03-01

    We propose a new design of a stacked three-layer flat-panel x-ray detector for dual-energy (DE) imaging. Each layer consists of its own scintillator of individual thickness and an underlying thin-film-transistor-based flat-panel. Three images are obtained simultaneously in the detector during the same x-ray exposure, thereby eliminating any motion artifacts. The detector operation is two-fold: a conventional radiography image can be obtained by combining all three layers' images, while a DE subtraction image can be obtained from the front and back layers' images, where the middle layer acts as a mid-filter that helps achieve spectral separation. We proceed to optimize the detector parameters for two sample imaging tasks that could particularly benefit from this new detector by obtaining the best possible signal to noise ratio per root entrance exposure using well-established theoretical models adapted to fit our new design. These results are compared to a conventional DE temporal subtraction detector and a single-shot DE subtraction detector with a copper mid-filter, both of which underwent the same theoretical optimization. The findings are then validated using advanced Monte Carlo simulations for all optimized detector setups. Given the performance expected from initial results and the recent decrease in price for digital x-ray detectors, the simplicity of the three-layer stacked imager approach appears promising to usher in a new generation of multi-spectral digital x-ray diagnostics.

  1. Signal and noise analysis of flat-panel sandwich detectors for single-shot dual-energy x-ray imaging

    Science.gov (United States)

    Kim, Dong Woon; Kim, Ho Kyung; Youn, Hanbean; Yun, Seungman; Han, Jong Chul; Kim, Junwoo; Kam, Soohwa; Tanguay, Jesse; Cunningham, Ian A.

    2015-03-01

    We have developed a novel sandwich-style single-shot (single-kV) detector by stacking two indirect-conversion flat-panel detectors for preclinical mouse imaging. In the sandwich detector structure, extra noise due to the direct x-ray absorption in photodiode arrays is inevitable. We develop a simple cascaded linear-systems model to describe signal and noise propagation in the flat-panel sandwich detector considering direct x-ray interactions. The noise-power spectrum (NPS) and detective quantum efficiency (DQE) obtained from the front and rear detectors are analyzed by using the cascaded-systems model. The NPS induced by the absorption of direct x-ray photons that are unattenuated within the photodiode layers is white in the spatial-frequency domain like the additive readout noise characteristic; hence that is harmful to the DQE at higher spatial frequencies at which the number of secondary quanta lessens. The model developed in this study will be useful for determining the optimal imaging techniques with sandwich detectors and their optimal design.

  2. A novel potential source of β-carotene: Eustigmatos cf. polyphem (Eustigmatophyceae) and pilot β-carotene production in bubble column and flat panel photobioreactors.

    Science.gov (United States)

    Li, Zhen; Ma, Xiaoqin; Li, Aifen; Zhang, Chengwu

    2012-08-01

    Carotenoids profile of the unicellular Eustigmatos cf. polyphem (Eustigmatophyceae) and β-carotene production of the microalga in bubble column and large flat panel bioreactors were studied. The microalga which contained β-carotene, violaxanthin and vaucheriaxanthin as the major carotenoids accumulated large amount of β-carotene. The β-carotene production of this microalga in the bubble column bioreactor was considerable, with the maximum intracellular β-carotene content reaching 60.76 mg g(-1), biomass reaching 9.2 g L(-1), and β-carotene yield up to 470.2 mg L(-1). The β-carotene productions in two large flat panel bioreactors were relatively lower, whereas over 100 mg β-carotene L(-1) was achieved. Besides, high light intensity helped to accumulate intracellular β-carotene and biomass. Deficient nitrate supply inhibited biomass growth, though it helped to accumulate β-carotene. Our results first proved that E. cf. polyphem was a potential source and producer of β-carotene, making it an interesting subject for further β-carotene study or commercial exploration.

  3. High-quality 3D correction of ring and radiant artifacts in flat panel detector-based cone beam volume CT imaging.

    Science.gov (United States)

    Anas, Emran Mohammad Abu; Kim, Jae Gon; Lee, Soo Yeol; Hasan, Md Kamrul

    2011-10-07

    The use of an x-ray flat panel detector is increasingly becoming popular in 3D cone beam volume CT machines. Due to the deficient semiconductor array manufacturing process, the cone beam projection data are often corrupted by different types of abnormalities, which cause severe ring and radiant artifacts in a cone beam reconstruction image, and as a result, the diagnostic image quality is degraded. In this paper, a novel technique is presented for the correction of error in the 2D cone beam projections due to abnormalities often observed in 2D x-ray flat panel detectors. Template images are derived from the responses of the detector pixels using their statistical properties and then an effective non-causal derivative-based detection algorithm in 2D space is presented for the detection of defective and mis-calibrated detector elements separately. An image inpainting-based 3D correction scheme is proposed for the estimation of responses of defective detector elements, and the responses of the mis-calibrated detector elements are corrected using the normalization technique. For real-time implementation, a simplification of the proposed off-line method is also suggested. Finally, the proposed algorithms are tested using different real cone beam volume CT images and the experimental results demonstrate that the proposed methods can effectively remove ring and radiant artifacts from cone beam volume CT images compared to other reported techniques in the literature.

  4. High-EPA Biomass from Nannochloropsis salina Cultivated in a Flat-Panel Photo-Bioreactor on a Process Water-Enriched Growth Medium

    DEFF Research Database (Denmark)

    Safafar, Hamed; Hass, Michael Z.; Møller, Per

    2016-01-01

    Nannochloropsis salina was grown on a mixture of standard growth media and pre-gasified industrial process water representing effluent from a local biogas plant. The study aimed to investigate the effects of enriched growth media and cultivation time on nutritional composition of Nannochloropsis...... salina biomass, with a focus on eicosapentaenoic acid (EPA). Variations in fatty acid composition, lipids, protein, amino acids, tocopherols and pigments were studied and results compared to algae cultivated on F/2 media as reference. Mixed growth media and process water enhanced the nutritional quality...... of Nannochloropsis salina in laboratory scale when compared to algae cultivated in standard F/2 medium. Data from laboratory scale translated to the large scaleusing a 4000 L flat panel photo-bioreactor system. The algae growth rate in winter conditions in Denmark was slow, but results revealed that large...

  5. Studies of the performance of different front-end systems for flat-panel multi-anode PMTs with CsI(Tl) scintillator arrays

    Energy Technology Data Exchange (ETDEWEB)

    Sekiya, H. [Department of Physics, Graduate School of Science, Kyoto University, Kitashirakawa, Sakyo, Kyoto 606-8502 (Japan)]. E-mail: sekiya@cr.scphys.kyoto-u.ac.jp; Hattori, K. [Department of Physics, Graduate School of Science, Kyoto University, Kitashirakawa, Sakyo, Kyoto 606-8502 (Japan); Kubo, H. [Department of Physics, Graduate School of Science, Kyoto University, Kitashirakawa, Sakyo, Kyoto 606-8502 (Japan); Miuchi, K. [Department of Physics, Graduate School of Science, Kyoto University, Kitashirakawa, Sakyo, Kyoto 606-8502 (Japan); Nagayoshi, T. [Advanced Research Institute for Science and Engineering, Waseda University, 17 Kikui-cho, Shinjuku, Tokyo 162-0044 (Japan); Nishimura, H. [Department of Physics, Graduate School of Science, Kyoto University, Kitashirakawa, Sakyo, Kyoto 606-8502 (Japan); Okada, Y. [Department of Physics, Graduate School of Science, Kyoto University, Kitashirakawa, Sakyo, Kyoto 606-8502 (Japan); Orito, R. [Department of Physics, Graduate School of Science and Technology, Kobe University, 1-1 Rokkoudai, Nada, Kobe 657-8501 (Japan); Takada, A. [Department of Physics, Graduate School of Science, Kyoto University, Kitashirakawa, Sakyo, Kyoto 606-8502 (Japan); Takeda, A. [Kamioka Observatory, ICRR, University of Tokyo, 456 Higasi-mozumi, Hida-shi, Gifu 506-1205 (Japan); Tanimori, T. [Department of Physics, Graduate School of Science, Kyoto University, Kitashirakawa, Sakyo, Kyoto 606-8502 (Japan); Ueno, K. [Department of Physics, Graduate School of Science, Kyoto University, Kitashirakawa, Sakyo, Kyoto 606-8502 (Japan)

    2006-07-01

    We have studied the performance of two different types of front-end systems for our gamma camera based on Hamamatsu H8500 (flat-panel 64 channels multi-anode PSPMT) with a CsI(Tl) scintillator array. The array consists of 64 pixels of 6x6x20mm{sup 3} which corresponds to the anode pixels of H8500. One of the system is based on commercial ASIC chips in order to read out every anode. The others are based on resistive charge divider network between anodes to reduce readout channels. In both systems, each pixel (6mm) was clearly resolved by flood field irradiation of {sup 137}Cs. We also investigated the energy resolution of these systems and showed the performance of the cascade connection of resistive network between some PMTs for large area detectors.

  6. Studies of the performance of different front-end systems for flat-panel multi-anode PMTs with CsI(Tl) scintillator arrays

    CERN Document Server

    Sekiya, H; Kubo, H; Miuchi, K; Nagayoshi, T; Nishimura, H; Okada, Y; Orito, R; Takada, A; Takeda, A; Tanimori, T; Ueno, K

    2006-01-01

    We have studied the performance of two different types of front-end systems for our gamma camera based on Hamamatsu H8500 (flat-panel 64 channels multi-anode PSPMT) with a CsI(Tl) scintillator array. The array consists of 64 pixels of $6\\times6\\times20{\\rm mm}^3$ which corresponds to the anode pixels of H8500. One of the system is based on commercial ASIC chips in order to readout every anode. The others are based on resistive charge divider network between anodes to reduce readout channels. In both systems, each pixel (6mm) was clearly resolved by flood field irradiation of $^{137}$Cs. We also investigated the energy resolution of these systems and showed the performance of the cascade connection of resistive network between some PMTs for large area detectors.

  7. Studies of the performance of different front-end systems for flat-panel multi-anode PMTs with CsI(Tl) scintillator arrays

    Science.gov (United States)

    Sekiya, H.; Hattori, K.; Kubo, H.; Miuchi, K.; Nagayoshi, T.; Nishimura, H.; Okada, Y.; Orito, R.; Takada, A.; Takeda, A.; Tanimori, T.; Ueno, K.

    2006-07-01

    We have studied the performance of two different types of front-end systems for our gamma camera based on Hamamatsu H8500 (flat-panel 64 channels multi-anode PSPMT) with a CsI(Tl) scintillator array. The array consists of 64 pixels of 6×6×20 mm3 which corresponds to the anode pixels of H8500. One of the system is based on commercial ASIC chips in order to read out every anode. The others are based on resistive charge divider network between anodes to reduce readout channels. In both systems, each pixel (6 mm) was clearly resolved by flood field irradiation of 137Cs. We also investigated the energy resolution of these systems and showed the performance of the cascade connection of resistive network between some PMTs for large area detectors.

  8. Close-Spaced Sublimation Growth and Characterization of Polycrystalline Cd1-xZnxTe Thick Films for Flat-Panel X-ray Detectors

    Science.gov (United States)

    Okamoto, Tamotsu; Kono, Makoto; Jibiki, Takayuki; Imai, Kiyokazu; Kishihara, Hiroyuki; Kaino, Masatomo; Tokuda, Satoshi; Sato, Toshiyuki

    2008-04-01

    Polycrystalline Cd1-xZnxTe thick films (x ˜0.05) with thicknesses above 400 µm were prepared by the close-spaced sublimation (CSS) as a conversion layer for next-generation highly efficient flat-panel X-ray detectors. The effects of the substrate temperature on the properties of the Cd1-xZnxTe layer were investigated, and it was found that the surface morphology and preferred crystallographic orientation depended on the substrate temperature. Furthermore, the control of the initial stage of deposition of Cd1-xZnxTe films was attempted, and high-quality Cd1-xZnxTe thick films were obtained by deposition after removing the surface layer of the sintered CdTe and ZnTe powder source.

  9. Alternating-direction method of multipliers estimation of attenuation and activity distributions in time-of-flight flat-panel positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Hsu, Yueh; Chou, Cheng-Ying [National Taiwan University, Taipei, Taiwan (China)

    2015-05-18

    A quantitative reconstruction of radiotracer activity distribution in positron emission tomography (PET) requires correction of attenuation, which was typically estimated through transmission measurements. The advancement in hardware development has prompted the use of time-of-flight (TOF) to improve PET imaging. Recently, the application of TOF-PET has been further extended to obtain attenuation map in addition to activity distribution simultaneously by use of iterative algorithms. Two flat-panel detectors are employed thus many transaxial lines of response are not detected. In this work, we applied the alternating-direction method of multipliers (ADMM) to simultaneously reconstruct TOF-PET and attenuation estimation in a dualhead small-animal PET system. The results were compared with those obtained by use of the maximum-likelihood algorithm. The computer simulation results showed that the application of the ADMM algorithm could greatly improve the image quality and reduce noisy appearance.

  10. The influence of liquid crystal display monitors on observer performance for the detection of interstitial lung markings on both storage phosphor and flat-panel-detector chest radiography

    Energy Technology Data Exchange (ETDEWEB)

    Sung, Yon Mi [Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50, Ilwon-dong, Kangnam-ku, Seoul 135-710 (Korea, Republic of); Department of Radiology, Gachon University Gil Hospital, 1198, Guwol-dong, Namdong-gu, Incheon 405-760 (Korea, Republic of); Chung, Myung Jin [Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50, Ilwon-dong, Kangnam-ku, Seoul 135-710 (Korea, Republic of)], E-mail: mj1.chung@samsung.com; Lee, Kyung Soo [Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50, Ilwon-dong, Kangnam-ku, Seoul 135-710 (Korea, Republic of); Choe, Bong-Keun [Department of Preventive Medicine, School of Medicine, Kyunghee University, Seoul (Korea, Republic of)

    2010-04-15

    Purpose: To compare observer performance with a flat-panel liquid crystal display (LCD) monitor and with a high-resolution gray-scale cathode ray tube (CRT) monitor in the detection of interstitial lung markings using a silicon flat-panel-detector direct radiography (DR) and storage phosphor computed radiography (CR) in a clinical setting. Materials and methods: We displayed 39 sets of posteroanterior chest radiographs from the patients who were suspected of interstitial lung disease. Each sets consisted of DR, CR and thin-section CT as the reference standard. Image identities were masked, randomly sorted, and displayed on both five mega pixel (2048 x 2560 x 8 bits) LCD and CRT monitors. Ten radiologists independently rated their confidence in detection for the presence of linear opacities in the four fields of the lungs; right upper, left upper, right lower, and left lower quadrant. Performance of a total 6240 (39 sets x 2 detector systems x 2 monitor system x 4 fields x 10 observers) observations was analyzed by multi-reader multi-case receiver operating characteristic (ROC) analysis. Differences between monitor systems in combinations of detector systems were compared using ANOVA and paired-samples t-test. Results: Area under curves (AUC) for the presence of linear opacities measured by ROC analysis was higher on the LCDs than CRTs without statistical significance (p = 0.082). AUC was significantly higher on the DR systems than CR systems (p = 0.006). AUC was significantly higher on the LCDs than CRTs for DR systems (p = 0.039) but not different for CR systems (p = 0.301). Conclusion: In clinical conditions, performance of the LCD monitor appears to be better for detecting interstitial lung markings when interfaced with DR systems.

  11. Model-based iterative reconstruction for flat-panel cone-beam CT with focal spot blur, detector blur, and correlated noise

    Science.gov (United States)

    Tilley, Steven, II; Siewerdsen, Jeffrey H.; Webster Stayman, J.

    2016-01-01

    While model-based reconstruction methods have been successfully applied to flat-panel cone-beam CT (FP-CBCT) systems, typical implementations ignore both spatial correlations in the projection data as well as system blurs due to the detector and focal spot in the x-ray source. In this work, we develop a forward model for flat-panel-based systems that includes blur and noise correlation associated with finite focal spot size and an indirect detector (e.g. scintillator). This forward model is used to develop a staged reconstruction framework where projection data are deconvolved and log-transformed, followed by a generalized least-squares reconstruction that utilizes a non-diagonal statistical weighting to account for the correlation that arises from the acquisition and data processing chain. We investigate the performance of this novel reconstruction approach in both simulated data and in CBCT test-bench data. In comparison to traditional filtered backprojection and model-based methods that ignore noise correlation, the proposed approach yields a superior noise-resolution tradeoff. For example, for a system with 0.34 mm FWHM scintillator blur and 0.70 FWHM focal spot blur, using the correlated noise model instead of an uncorrelated noise model increased resolution by 42% (with variance matched at 6.9  ×  10-8 mm-2). While this advantage holds across a wide range of systems with differing blur characteristics, the improvements are greatest for systems where source blur is larger than detector blur.

  12. The Usage of Flat Panel Solar Heater Balcony Style%平板式阳台壁挂太阳能应用浅析

    Institute of Scientific and Technical Information of China (English)

    张子涵

    2014-01-01

    随着世界范围内的能源短缺和人们环保意识的增强,新能源和可再生能源技术将是21世纪世界经济发展中最具有决定性影响的技术领域之一,而太阳能作为取之不尽、生态学上纯净的和不改变地球上燃料平衡的能源,有着能源总量大,又容易实现小型化的优点,被认为是21世纪最重要的新能源。太阳能热水器将会成为改变人们生活的一大重要产品。平板式阳台壁挂太阳能成功解决了传统太阳能热水器安装中存在的瓶颈问题,成功实现了建筑一体化。本文就平板式阳台壁挂太阳能的应用方面做了一些探索研究。%Along with the shortage of energy and enhance of environment protection, renewable energy industry has become one of the most effective ones in the new century which can greatly affect people's life. As a clean and renewable energy, solar energy has been consid-ered as the most important new energy with the characteristics of renewable, endless and easy to reach. Flat panel solar heater greatly im-proved the traditional solar heaters shortcomings and realized the perfect combination with tal buildings. In this text, we have some study of the usage of flat panel solar heaters.

  13. Microcavity effects in the photoluminescence of hydrogenated amorphous silicon nitride

    Science.gov (United States)

    Serpenguzel, Ali; Aydinli, Atilla; Bek, Alpan

    1998-07-01

    Fabry-Perot microcavities are used for the alteration of photoluminescence in hydrogenated amorphous silicon nitride grown with and without ammonia. The photoluminescence is red-near-infrared for the samples grown without ammonia, and blue-green for the samples grown with ammonia. In the Fabry- Perot microcavities, the amplitude of the photoluminescence is enhanced, while its linewidth is reduced with respect to the bulk hydrogenated amorphous silicon nitride. The microcavity was realized by a metallic back mirror and a hydrogenated amorphous silicon nitride--air or a metallic front mirror. The transmittance, reflectance, and absorbance spectra were also measured and calculated. The calculated spectra agree well with the experimental spectra. The hydrogenated amorphous silicon nitride microcavity has potential for becoming a versatile silicon based optoelectronic device such as a color flat panel display, a resonant cavity enhanced light emitting diode, or a laser.

  14. Report of the results of the fiscal 1997 regional consortium R and D project. Regional consortium energy field/R and D high performance flat panel display technology (first fiscal year); 1997 nendo chiiki consortium kenkyu kaihatsu jigyo. Chiiki consortium energy bun`ya / koseino flat panel display gijutsu no sogo kaihatsu kenkyu (daiichi nendo ) seika hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-01

    One of the subjects in technology supporting the highly information-oriented society which will develop and diversify toward the 21st century is the construction of high grade man/machine interface. For it, high precision/high luminance/energy saving/thin plane displays are strongly requested. This R and D is to indicate models of systematical development in the region of element technology individually existing in the Shikoku area by forming a regional consortium in the industry/universities/government. Creation of new industries by gathering display related enterprises is a first step in a plan to realize `Display Island Shikoku.` As a concrete target, with the use of high-tech diamond semiconducting technology, a development is conducted of the high performance flat panel display using the negative electron affinity (NEA) electron emitter which drastically solves the problems such as luminance, visibility angle and response speed, the subjects on the commercialized liquid crystal flat panel display. 16 refs., 45 figs., 8 tabs.

  15. Hydrogen production by the engineered cyanobacterial strain Nostoc PCC 7120 ΔhupW examined in a flat panel photobioreactor system.

    Science.gov (United States)

    Nyberg, Marcus; Heidorn, Thorsten; Lindblad, Peter

    2015-12-10

    Nitrogenase based hydrogen production was examined in a ΔhupW strain of the filamentous heterocystous cyanobacterium Nostoc PCC 7120, i.e., cells lacking the last step in the maturation system of the large subunit of the uptake hydrogenase and as a consequence with a non-functional uptake hydrogenase. The cells were grown in a developed flat panel photobioreactor system with 3.0L culture volume either aerobically (air) or anaerobically (Ar or 80% N2/20% Ar) and illuminated with a mixture of red and white LED. Aerobic growth of the ΔhupW strain of Nostoc PCC 7120 at 44μmolar photons m(-2)s(-1) PAR gave the highest hydrogen production of 0.7mL H2 L(-1)h(-1), 0.53mmol H2 mg chlorophyll a(-1)h(-1), and a light energy conversion efficiency of 1.2%. Anaerobic growth using 100% argon showed a maximal hydrogen production of 1.7mLL(-1)h(-1), 0.85mmol per mg chlorophyll a(-1) h(-1), and a light energy conversion efficiency of 2.7%. Altering between argon/N2 (20/80) and 100% argon phases resulted in a maximal hydrogen production at hour 128 (100% argon phase) with 6.2mL H2L(-1)h(-1), 0.71mL H2 mg chlorophyll a(-1)h(-1), and a light energy efficiency conversion of 4.0%. The highest buildup of hydrogen gas observed was 6.89% H2 (100% argon phase) of the total photobioreactor system with a maximal production of 4.85mL H2 L(-1)h(-1). The present study clearly demonstrates the potential to use purpose design cyanobacteria in developed flat panel photobioreactor systems for the direct production of the solar fuel hydrogen. Further improvements in the strain used, environmental conditions employed, and growth, production and collection systems used, are needed before a sustainable and economical cyanobacterial based hydrogen production can be realized.

  16. Selenium essentials

    CERN Document Server

    Sams, Prashanth

    2015-01-01

    If you are a developer who wants to migrate from Selenium RC or any other automation tool to Selenium WebDriver, then this book is for you. Knowledge of automation tools is necessary to follow the examples in this book.

  17. A Ring Artifact Correction Method: Validation by Micro-CT Imaging with Flat-Panel Detectors and a 2D Photon-Counting Detector

    Directory of Open Access Journals (Sweden)

    Mohamed Elsayed Eldib

    2017-01-01

    Full Text Available We introduce an efficient ring artifact correction method for a cone-beam computed tomography (CT. In the first step, we correct the defective pixels whose values are close to zero or saturated in the projection domain. In the second step, we compute the mean value at each detector element along the view angle in the sinogram to obtain the one-dimensional (1D mean vector, and we then compute the 1D correction vector by taking inverse of the mean vector. We multiply the correction vector with the sinogram row by row over all view angles. In the third step, we apply a Gaussian filter on the difference image between the original CT image and the corrected CT image obtained in the previous step. The filtered difference image is added to the corrected CT image to compensate the possible contrast anomaly that may appear due to the contrast change in the sinogram after removing stripe artifacts. We applied the proposed method to the projection data acquired by two flat-panel detectors (FPDs and a silicon-based photon-counting X-ray detector (PCXD. Micro-CT imaging experiments of phantoms and a small animal have shown that the proposed method can greatly reduce ring artifacts regardless of detector types. Despite the great reduction of ring artifacts, the proposed method does not compromise the original spatial resolution and contrast.

  18. Does Preinterventional Flat-Panel Computer Tomography Pooled Blood Volume Mapping Predict Final Infarct Volume After Mechanical Thrombectomy in Acute Cerebral Artery Occlusion?

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, Marlies, E-mail: marlies.wagner@kgu.de [Hospital of Goethe University, Institute of Neuroradiology (Germany); Kyriakou, Yiannis, E-mail: yiannis.kyriakou@siemens.com [Siemens AG, Health Care Sector (Germany); Mesnil de Rochemont, Richard du, E-mail: mesnil@em.uni-frankfurt.de [Hospital of Goethe University, Institute of Neuroradiology (Germany); Singer, Oliver C., E-mail: o.singer@em.uni-frankfurt.de [Hospital of Goethe University, Department of Neurology (Germany); Berkefeld, Joachim, E-mail: berkefeld@em.uni-frankfurt.de [Hospital of Goethe University, Institute of Neuroradiology (Germany)

    2013-08-01

    PurposeDecreased cerebral blood volume is known to be a predictor for final infarct volume in acute cerebral artery occlusion. To evaluate the predictability of final infarct volume in patients with acute occlusion of the middle cerebral artery (MCA) or the distal internal carotid artery (ICA) and successful endovascular recanalization, pooled blood volume (PBV) was measured using flat-panel detector computed tomography (FPD CT).Materials and MethodsTwenty patients with acute unilateral occlusion of the MCA or distal ACI without demarcated infarction, as proven by CT at admission, and successful Thrombolysis in cerebral infarction score (TICI 2b or 3) endovascular thrombectomy were included. Cerebral PBV maps were acquired from each patient immediately before endovascular thrombectomy. Twenty-four hours after recanalization, each patient underwent multislice CT to visualize final infarct volume. Extent of the areas of decreased PBV was compared with the final infarct volume proven by follow-up CT the next day.ResultsIn 15 of 20 patients, areas of distinct PBV decrease corresponded to final infarct volume. In 5 patients, areas of decreased PBV overestimated final extension of ischemia probably due to inappropriate timing of data acquisition and misery perfusion.ConclusionPBV mapping using FPD CT is a promising tool to predict areas of irrecoverable brain parenchyma in acute thromboembolic stroke. Further validation is necessary before routine use for decision making for interventional thrombectomy.

  19. Cascaded-Systems Analysis of Flat-Panel Sandwich Detectors for Single-Shot Dual-Energy X-ray Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ho Kyung; Kim, Dong Woon; Kim, Junwoo; Youn, Hanbean [Pusan National University, Busan (Korea, Republic of)

    2015-05-15

    We have developed the cascaded-systems model to investigate the signal and noise characteristics in the flat-panel sandwich detector which was developed for the preclinical single-shot dual-energy x-ray imaging. The model incorporates parallel branches to include direct interaction of x-rays in photodiode that is unavoidable in the sandwich structure with a corresponding potential increase in image noise. The model has been validated in comparison with the experimental. The cascaded-systems analysis shows that direct x-ray interaction noise behaves as additive electronic noise that is white in the frequency domain; hence it is harmful to the DQE at higher frequencies where the number of secondary quanta lessens. Even at zero frequency, the direct x-ray interaction noise can reduce the DQE of the detectors investigated in this study by ∼20% for the 60 kV x-ray spectrum. The DQE of rear detector in the sandwich structure is sensitive to additive electronic noise because of the enhancement in the number of electronic noise quanta relative to that of x-ray quanta that are attenuated through the front layers including the intermediate filter layer (i.e. incident photon fluence times transmission factor)

  20. Flat-Panel Detector—Based Volume Computed Tomography: A Novel 3D Imaging Technique to Monitor Osteolytic Bone Lesions in a Mouse Tumor Metastasis Model

    Directory of Open Access Journals (Sweden)

    Jeannine Missbach-Guentner

    2007-09-01

    Full Text Available Skeletal metastasis is an important cause of mortality in patients with breast cancer. Hence, animal models, in combination with various imaging techniques, are in high demand for preclinical assessment of novel therapies. We evaluated the applicability of flat-panel volume computed tomography (fpVCT to noninvasive detection of osteolytic bone metastases that develop in severe immunodeficient mice after intracardial injection of MDA-MB-231 breast cancer cells. A single fpVCT scan at 200-wm isotropic resolution was employed to detect osteolysis within the entire skeleton. Osteolytic lesions identified by fpVCT correlated with Faxitron X-ray analysis and were subsequently confirmed by histopathological examination. Isotropic three-dimensional image data sets obtained by fpVCT were the basis for the precise visualization of the extent of the lesion within the cortical bone and for the measurement of bone loss. Furthermore, fpVCT imaging allows continuous monitoring of growth kinetics for each metastatic site and visualization of lesions in more complex regions of the skeleton, such as the skull. Our findings suggest that fpVCT is a powerful tool that can be used to monitor the occurrence and progression of osteolytic lesions in vivo and can be further developed to monitor responses to antimetastatic therapies over the course of the disease.

  1. Modeling shift-variant X-ray focal spot blur for high-resolution flat-panel cone-beam CT

    CERN Document Server

    Tilley, Steven; Siewerdsen, Jeffrey H; Stayman, J Webster

    2016-01-01

    Flat-panel cone-beam CT (CBCT) has been applied clinically in a number of high-resolution applications. Increasing geometric magnification can potentially improve resolution, but also increases blur due to an extended x-ray focal-spot. We present a shift-variant focal-spot blur model and incorporate it into a model-based iterative-reconstruction algorithm. We apply this algorithm to simulation and CBCT test-bench data. In a trabecular bone simulation study, we find traditional reconstruction approaches without a blur model exhibit shift-variant resolution properties that depend greatly on the acquisition protocol (e.g. short vs. full scans) and the anode angles of the rays used to reconstruct a particular region. For physical CBCT experiments focal spot blur was characterized and a spatial resolution phantom was scanned and reconstructed. In both experiments image quality using the shift-variant model was significantly improved over approaches that modeled no blur or only a shift-invariant blur, suggesting a ...

  2. A Ring Artifact Correction Method: Validation by Micro-CT Imaging with Flat-Panel Detectors and a 2D Photon-Counting Detector

    Science.gov (United States)

    Eldib, Mohamed Elsayed; Hegazy, Mohamed; Mun, Yang Ji; Cho, Myung Hye; Cho, Min Hyoung; Lee, Soo Yeol

    2017-01-01

    We introduce an efficient ring artifact correction method for a cone-beam computed tomography (CT). In the first step, we correct the defective pixels whose values are close to zero or saturated in the projection domain. In the second step, we compute the mean value at each detector element along the view angle in the sinogram to obtain the one-dimensional (1D) mean vector, and we then compute the 1D correction vector by taking inverse of the mean vector. We multiply the correction vector with the sinogram row by row over all view angles. In the third step, we apply a Gaussian filter on the difference image between the original CT image and the corrected CT image obtained in the previous step. The filtered difference image is added to the corrected CT image to compensate the possible contrast anomaly that may appear due to the contrast change in the sinogram after removing stripe artifacts. We applied the proposed method to the projection data acquired by two flat-panel detectors (FPDs) and a silicon-based photon-counting X-ray detector (PCXD). Micro-CT imaging experiments of phantoms and a small animal have shown that the proposed method can greatly reduce ring artifacts regardless of detector types. Despite the great reduction of ring artifacts, the proposed method does not compromise the original spatial resolution and contrast. PMID:28146088

  3. 聚合物发光二极管面光源的光热特性%Optical and Thermal Analysis for Polymer Light-emitting Diode as A Flat Panel Light Source

    Institute of Scientific and Technical Information of China (English)

    桂宇畅; 林昊天; 刘艳梅; 张剑平; 文尚胜

    2011-01-01

    运用传输矩阵法及MATLAB软件模拟计算了以MEH-PPV为发光材料的PLED面光源出光率,分析了发光层、PEDOT层、ITO层对器件出光率的影响.模拟分析了玻璃表面半球形、圆台形、圆锥形3种微形貌对器件出光率的影响.仿真结果表明,玻璃表面为圆锥形微散射层对提高器件出光率最有利,且出光均匀性最好.最后分析了PLED面光源工作状态下的热特性,发现发光层的热量容易积聚不易导出.该研究为大面积有机发光照明的优化设计提供了理论依据.%The light out-coupling efficiency of polymer light-emitting devices (PLED) flat panel based on poly [2-me-thoxy-5-(2-ethyl-hexyloxy )-l, 4-phenylenevinylene] (MEH-PPV) was simulated by applying the transfer matrix method and software MATLAB. The influence of emitting layer, PEDOT layer, ITO layer on the performance of the PLED flat panel' s out-coupling efficiency was studied. The influence of different micro shapes on glass surface, such as flat panel, hemispherical shape,circular mesa,and conical shape, is simulated by software TRACEPRO. The results show that the light out-coupling efficiency is the largest and the uniformity of flat panel light output is the best when the glass surface is with micro conical shape. At last, the thermal properties were studied during the working of PLED flat panel. A great quantity of heat in emitting layer can not be diffused quickly. These results provided a basis for the optical and thermal optimization of PLED flat panel light source.

  4. Cone-beam CT with a flat-panel detector on a mobile C-arm: preclinical investigation in image-guided surgery of the head and neck

    Science.gov (United States)

    Siewerdsen, J. H.; Chan, Y.; Rafferty, M. A.; Moseley, D. J.; Jaffray, D. A.; Irish, J. C.

    2005-04-01

    A promising imaging platform for combined low-dose fluoroscopy and cone-beam CT (CBCT) guidance of interventional procedures has been developed in our laboratory. Based on a mobile isocentric C-arm (Siemens PowerMobil) incorporating a high-performance flat-panel detector (Varian PaxScan 4030CB), the system demonstrates sub-mm 3D spatial resolution and soft-tissue visibility with field of view sufficient for head and body sites. For pre-clinical studies in head neck tumor surgery, we hypothesize that the 3D intraoperative information provided by CBCT permits precise, aggressive techniques with improved avoidance of critical structures. The objectives include: 1) quantify improvement in surgical performance achieved with CBCT guidance compared to open and endoscopic techniques; and 2) investigate specific, challenging surgical tasks under CBCT guidance. Investigations proceed from an idealized phantom model to cadaveric specimens. A novel surgical performance evaluation method based on statistical decision theory is applied to excision and avoidance tasks. Analogous to receiver operating characteristic (ROC) analysis in medical imaging, the method quantifies surgical performance in terms of Lesion-Excised (True-Positve), Lesion-Remaining (False-Negative), Normal-Excised (False-Positive), and Normal-Remaining (True-Negative) fractions. Conservative and aggressive excision and avoidance tasks are executed in 12 cadaveric specimens with and without CBCT guidance, including: dissection through dura, preservation of posterior lamina, ethmoid air cells removal, exposure of peri-orbita, and excision of infiltrated bone in the skull base (clivus). Intraoperative CBCT data was found to dramatically improve surgical performance and confidence in the execution of such tasks. Pre-clinical investigation of this platform in head and neck surgery, as well as spinal, trauma, biopsy, and other nonvascular procedures, is discussed.

  5. High-EPA Biomass from Nannochloropsis salina Cultivated in a Flat-Panel Photo-Bioreactor on a Process Water-Enriched Growth Medium

    Directory of Open Access Journals (Sweden)

    Hamed Safafar

    2016-07-01

    Full Text Available Nannochloropsis salina was grown on a mixture of standard growth media and pre-gasified industrial process water representing effluent from a local biogas plant. The study aimed to investigate the effects of enriched growth media and cultivation time on nutritional composition of Nannochloropsis salina biomass, with a focus on eicosapentaenoic acid (EPA. Variations in fatty acid composition, lipids, protein, amino acids, tocopherols and pigments were studied and results compared to algae cultivated on F/2 media as reference. Mixed growth media and process water enhanced the nutritional quality of Nannochloropsis salina in laboratory scale when compared to algae cultivated in standard F/2 medium. Data from laboratory scale translated to the large scale using a 4000 L flat panel photo-bioreactor system. The algae growth rate in winter conditions in Denmark was slow, but results revealed that large-scale cultivation of Nannochloropsis salina at these conditions could improve the nutritional properties such as EPA, tocopherol, protein and carotenoids compared to laboratory-scale cultivated microalgae. EPA reached 44.2% ± 2.30% of total fatty acids, and α-tocopherol reached 431 ± 28 µg/g of biomass dry weight after 21 days of cultivation. Variations in chemical compositions of Nannochloropsis salina were studied during the course of cultivation. Nannochloropsis salina can be presented as a good candidate for winter time cultivation in Denmark. The resulting biomass is a rich source of EPA and also a good source of protein (amino acids, tocopherols and carotenoids for potential use in aquaculture feed industry.

  6. MTF characterization in 2D and 3D for a high resolution, large field of view flat panel imager for cone beam CT

    Science.gov (United States)

    Shah, Jainil; Mann, Steve D.; Tornai, Martin P.; Richmond, Michelle; Zentai, George

    2014-03-01

    The 2D and 3D modulation transfer functions (MTFs) of a custom made, large 40x30cm2 area, 600- micron CsI-TFT based flat panel imager having 127-micron pixellation, along with the micro-fiber scintillator structure, were characterized in detail using various techniques. The larger area detector yields a reconstructed FOV of 25cm diameter with an 80cm SID in CT mode. The MTFs were determined with 1x1 (intrinsic) binning. The 2D MTFs were determined using a 50.8 micron tungsten wire and a solid lead edge, and the 3D MTF was measured using a custom made phantom consisting of three nearly orthogonal 50.8 micron tungsten wires suspended in an acrylic cubic frame. The 2D projection data was reconstructed using an iterative OSC algorithm using 16 subsets and 5 iterations. As additional verification of the resolution, along with scatter, the Catphan® phantom was also imaged and reconstructed with identical parameters. The measured 2D MTF was ~4% using the wire technique and ~1% using the edge technique at the 3.94 lp/mm Nyquist cut-off frequency. The average 3D MTF measured along the wires was ~8% at the Nyquist. At 50% MTF, the resolutions were 1.2 and 2.1 lp/mm in 2D and 3D, respectively. In the Catphan® phantom, the 1.7 lp/mm bars were easily observed. Lastly, the 3D MTF measured on the three wires has an observed 5.9% RMSD, indicating that the resolution of the imaging system is uniform and spatially independent. This high performance detector is integrated into a dedicated breast SPECT-CT imaging system.

  7. Effect of x-ray incident direction and scintillator layer design on image quality of indirect-conversion flat-panel detector with GOS phosphor

    Science.gov (United States)

    Sato, K.; Nariyuki, F.; Nomura, H.; Takasu, A.; Fukui, S.; Nakatsu, M.; Okada, Y.; Nabeta, T.; Hosoi, Y.

    2011-03-01

    In this study, we characterized the image quality of two types of indirect-conversion flat-panel detectors: an X-ray incident-side photo-detection system (IS) and an X-ray penetration-side photo-detection system (PS). These detectors consist of a Gd2O2S:Tb (GOS) scintillator coupled with a photodiode thin film transistor (PD-TFT) array on a glass substrate. The detectors have different X-ray incident directions, glass substrates, and scintillators. We also characterized the effects of layered scintillator structures on the image quality by using a single-layered scintillator containing large phosphor grains and a double-layered scintillator consisting of a layer of large phosphor grains and a layer of small phosphor grains. The IS system consistently demonstrated a higher MTF than the PS system for a scintillator of the same thickness. Moreover, the IS system showed a higher DQE than the PS system when a thick scintillator was used. While the double-layered scintillators were useful for improving the MTF in both systems, a thick single-layered scintillator was preferable for obtaining a high DQE when the IS system was applied. These results indicate that an IS system can efficiently utilize the light emitted from the phosphor at the far side of the PD without the occurrence of blurring. The use of IS systems makes it possible to increase the thickness of the scintillator layer for improving the sensitivity without reducing the MTF, which increases the DQE. The DQE of the IS system was 1.2 times that of the PS system, despite the absorption of X-rays at the glass substrate before entering the phosphor.

  8. Imaging responses of on-site CsI and Gd2O2S flat-panel detectors: Dependence on the tube voltage

    Science.gov (United States)

    Jeon, Hosang; Chung, Myung Jin; Youn, Seungman; Nam, Jiho; Lee, Jayoung; Park, Dahl; Kim, Wontaek; Ki, Yongkan; Kim, Ho Kyung

    2015-07-01

    One of the emerging issues in radiography is low-dose imaging to minimize patient's exposure. The scintillating materials employed in most indirect flat-panel detectors show a drastic change of X-ray photon absorption efficiency around their K-edge energies that consequently affects image quality. Using various tube voltages, we investigated the imaging performance of most popular scintillators: cesium iodide (CsI) and gadolinium oxysulfide (Gd2O2S). The integrated detective quantum efficiencies (iDQE) of four detectors installed in the same hospital were evaluated according to the standardized procedure IEC 62220-1 at tube voltages of 40 - 120 kVp. The iDQE values of the Gd2O2S detectors were normalized by those of CsI detectors to exclude the effects of image postprocessing. The contrast-to-noise ratios (CNR) were also evaluated by using an anthropomorphic chest phantom. The iDQE of the CsI detector outperformed that of the Gd2O2S detector over all tube voltages. Moreover, we noted that the iDQE of the Gd2O2S detectors quickly rolled off with decreasing tube voltage under 70 kVp. The CNRs of the two scintillators were similar at 120 kVp. At 60 kVp, however, the CNR of Gd2O2S was about half that of CsI. Compared to the Gd2O2S detectors, variations in the DQE performance of the CsI detectors were relatively immune to variations in the applied tube voltages. Therefore, we claim that Gd2O2S detectors are inappropriate for use in low-tube-voltage imaging (e.g., extremities and pediatrics) with low patient exposure.

  9. Radiation dose reduction in scoliosis patients. Low-dose full-spine radiography with digital flat panel detector and image stitching system

    Energy Technology Data Exchange (ETDEWEB)

    Grieser, T. [Klinikum Augsburg (Germany). Klinik fuer Diagnostische Radiologie und Neuroradiologie; Baldauf, A.Q. [Theresienkrankenhaus Mannheim (Germany). Abt. fuer Radiologie; Ludwig, K. [Klinikum Herford (Germany). Klinik fuer Diagnostische und Interventionelle Radiologie

    2011-07-15

    Purpose: To evaluate the exposure dose reduction with a digital flat panel detector (FPD) and an image stitching system (ISS) in full-spine radiography for scoliosis patients. Materials and Methods: During a 6-month period, all consecutive scoliosis patients with a clinical indication for full-spine radiography (n = 50) were examined with an FPD and ISS. Automatic exposure control adjusted to speed class 1600 was used together with age-adjusted tube voltage and filtration. Dose area products were recorded for all images (antero-posterior n = 50, lateral n = 18). Images were evaluated by two radiologists for the possibility (possible, impossible) of typical scoliosis measurements (Cobb angle, Stagnara angle, lateral deviation, Risser stage). All measurements assessed as impossible underwent a second evaluation categorizing the reason why a measurement was impossible (underlying pathology, projection, image quality). Patient characteristics influencing exposure were recorded (sex, age, weight, height). Mean dose area products were compared to the literature with consideration of patient group and image quality. Results: The mean dose area product was 16.8 {mu}Gy m{sup 2} for antero-posterior images and 26.6 {mu}Gy m{sup 2} for lateral images. A comparison to published values showed an exposure dose reduction of 47 % to 93 %. Measurement of the Cobb and Stagnara angle, lateral deviation and Risser stage was possible in 96 % (n = 50), 83 % (n = 18), 100 % (n = 50) and 100 % (n = 50) of cases. The reasons for impossible measurements were independent of image quality (underlying pathologies, projection). Conclusion: When imaging scoliosis patients, an FPD combined with an ISS can substantially reduce the exposure dose. (orig.)

  10. COCHLEAR LENGTH DETERMINATION IN TEMPORAL BONE SPECIMENS USING HISTOLOGICAL SERIAL MICRO GRINDING IMAGING, MICRO COMPUTED TOMOGRAPHY AND FLAT-PANEL VOLUMETRIC COMPUTED TOMOGRAPHY

    Directory of Open Access Journals (Sweden)

    Waldemar Würfel

    2015-04-01

    Full Text Available The cochlear length virtually describes the length of the cochlea in a straight line. Several theoretical options for measuring the length of the cochlea are conceivable. In choosing the type of cochlear implant electrode, this can play a crucial role. A wide range of electrodes is available, especially among the models designed to preserve residual hearing and structural integrity. It is believed that the depth of cochlear implant electrode insertion has an influence on the functional hearing based on the area of the cochlea that is electrically stimulated. Method: Imaging of nine human temporal bone specimens was performed using histological serial microgrinding imaging, micro computed tomography (microCT and experimental flat-panel volumetric computed tomography (fpVCT. Measurements were then performed by outlining the cochlea in OsiriX (Pixmeo, Los Angeles USA. Results: The cochlear length of 9 human temporal bones was determined in each histological serial microgrinding imaging, fpVCT and microCT. Cochlear length ranges in histological serial grinding imaging from 45.3 mm to 38.7 mm, in microCT from 46.1 mm to 39.3 mm and in fpVCT from 45.8 mm to 39.8 mm. Significant inter- and intraindividual differences in the cochlear length were observed. The presented methodology is capable of determining the cochlear length in each imaging modality. Discussion: A methodology to experimentally determine the cochlear length is interesting from both clinical and preclinical perspectives. Insertion studies are highly relevant to the development and evaluation of new electrode arrays. This study presents a measurement methodology that allows for individualized cochlear length measurement based on three established imaging modalities. The data presented here confirm differences in cochlear length. The method described here can be used to evaluate a cochlea in an experimental setting. This allows an individualized, pre-interventional evaluation of the

  11. SU-E-I-11: Cascaded Linear System Model for Columnar CsI Flat Panel Imagers with Depth Dependent Gain and Blur

    Energy Technology Data Exchange (ETDEWEB)

    Peng, B; Lubinsky, A; Zheng, H; Zhao, W [Stony Brook University, Stony Brook, NY (United States); Teymurazyan, A [Lakehead University, Thunder Bay, Ontario (Canada)

    2014-06-01

    Purpose: To implement a depth dependent gain and blur cascaded linear system model (CLSM) for optimizing columnar structured CsI indirect conversion flat panel imager (FPI) for advanced imaging applications. Methods: For experimental validation, depth dependent escape efficiency, e(z), was extracted from PHS measurement of different CsI scintillators (thickness, substrate and light output). The inherent MTF and DQE of CsI was measured using high resolution CMOS sensor. For CLSM, e(z) and the depth dependent MTF(f,z), were estimated using Monte Carlo simulation (Geant4) of optical photon transport through columnar CsI. Previous work showed that Monte Carlo simulation for CsI was hindered by the non-ideality of its columnar structure. In the present work we allowed variation in columnar width with depth, and assumed diffusive reflective backing and columns. Monte Carlo simulation was performed using an optical point source placed at different depth of the CsI layer, from which MTF(z,f) and e(z) were computed. The resulting e(z) with excellent matching with experimental measurements were then applied to the CLSM, Monte Carlo simulation was repeated until the modeled MTF, DQE(f) also match experimental measurement. Results: For a 150 micron FOS HL type CsI, e(z) varies between 0.56 to 0.45, and the MTF at 14 cycles/mm varies between 62.1% to 3.9%, from the front to the back of the scintillator. The overall MTF and DQE(f) at all frequencies are in excellent agreement with experimental measurements at all frequencies. Conclusion: We have developed a CLSM for columnar CsI scintillators with depth dependent gain and MTF, which were estimated from Monte Carlo simulation with novel optical simulation settings. Preliminary results showed excellent agreement between simulation results and experimental measurements. Future work is aimed at extending this approach to optimize CsI screen optic design and sensor structure for achieving higher DQE(f) in cone-beam CT, which uses

  12. Psychophysical evaluation of the image quality of a dynamic flat-panel digital x-ray image detector using the threshold contrast detail detectability (TCDD) technique

    Science.gov (United States)

    Davies, Andrew G.; Cowen, Arnold R.; Bruijns, Tom J. C.

    1999-05-01

    We are currently in an era of active development of the digital X-ray imaging detectors that will serve the radiological communities in the new millennium. The rigorous comparative physical evaluations of such devices are therefore becoming increasingly important from both the technical and clinical perspectives. The authors have been actively involved in the evaluation of a clinical demonstration version of a flat-panel dynamic digital X-ray image detector (or FDXD). Results of objective physical evaluation of this device have been presented elsewhere at this conference. The imaging performance of FDXD under radiographic exposure conditions have been previously reported, and in this paper a psychophysical evaluation of the FDXD detector operating under continuous fluoroscopic conditions is presented. The evaluation technique employed was the threshold contrast detail detectability (TCDD) technique, which enables image quality to be measured on devices operating in the clinical environment. This approach addresses image quality in the context of both the image acquisition and display processes, and uses human observers to measure performance. The Leeds test objects TO[10] and TO[10+] were used to obtain comparative measurements of performance on the FDXD and two digital spot fluorography (DSF) systems, one utilizing a Plumbicon camera and the other a state of the art CCD camera. Measurements were taken at a range of detector entrance exposure rates, namely 6, 12, 25 and 50 (mu) R/s. In order to facilitate comparisons between the systems, all fluoroscopic image processing such as noise reduction algorithms, were disabled during the experiments. At the highest dose rate FDXD significantly outperformed the DSF comparison systems in the TCDD comparisons. At 25 and 12 (mu) R/s all three-systems performed in an equivalent manner and at the lowest exposure rate FDXD was inferior to the two DSF systems. At standard fluoroscopic exposures, FDXD performed in an equivalent

  13. Daily quality control of collimator multi-leaf for IMRT static through flat panel (EPID); Control de calidad diario del colimador multilamina para IMRT estatica mediante panel plano (EPID)

    Energy Technology Data Exchange (ETDEWEB)

    Gomez Barrado, A.; Benitez Serrano, J. A.; Sanchez Jimenez, E.; Sanchez-Reyes, A.

    2013-07-01

    When techniques are employed such as radiotherapy for intensity modulated (IMRT) is necessary to establish a proper quality assurance program. According to national and international recommendations, such a program must include, in addition to verification of treatment for each patient, a multi-leaf collimator quality control daily, easy to perform and analyze, to ensure the quality of the given treatments daily. This paper intends to make such quality control through the irradiation of a number of fields in the imaging system flat panel portal and its subsequent analysis. (Author)

  14. Nutritional aspects of selenium

    Energy Technology Data Exchange (ETDEWEB)

    Choe, M.

    1987-01-01

    The overall objective of this project was to investigate the effect of protein and/or dietary fiber supplementation on selenium absorption and metabolism. These relationships might be of importance in determining either minimum selenium nutritional requirements or levels of intake at which this mineral becomes toxic. Three studies compose the project. The first study involved the controlled feeding of fifteen young adults mice. Subjects were fed a laboratory-controlled diet with and without supplements of selenium or selenium plus guar gum. Selenium supplementation resulted in increased selenium excretion in urine and feces. Supplementation of guar gum, as a dietary fiber, tended to increase fecal selenium excretion and to decrease selenium balance and glutathione peroxidase (GSH-Px) activity regardless of dietary selenium levels. In study II, seventy two weanling mice were fed varied levels of dietary selenium and protein. Numerically, urinary selenium excretion increased and fecal selenium excretion and selenium balance decreased with increased dietary protein level within the same level of dietary selenium; however, selenium absorption rate tended to decrease with increased dietary protein level. Whole blood and brain tissue glutathione peroxidase activities were higher in animals fed moderate protein level than those fed the other two protein levels. In study III, a survey was conducted to investigate the correlation between dietary fiber or protein intake and urinary selenium excretion. There was a negative correlation between dietary fiber and urinary selenium excretion levels while dietary protein and urinary selenium excretion were positively correlated.

  15. Flat-Panel CT as a new perinterventional imaging modality in aortic stentgraft procedures. Work in progress; Flachdetektor-CT als ergaenzende Untersuchung bei der endoluminalen Behandlung von thorakalen und abdominellen Aortenaneurysmen. Erste klinische Erfahrungen

    Energy Technology Data Exchange (ETDEWEB)

    Rabitsch, E.; Celedin, S.; Kau, T.; Illiasch, H.; Hausegger, K. [Inst. fuer diagnostische und interventionelle Radiologie, LKH Klagenfurt (Austria)

    2008-02-15

    Purpose: to evaluate the value of flat-panel CT (FP-CT) as a new perinterventional imaging modality in aortic stentgraft procedures. Materials and methods: FP-CT was performed in 21 patients (19 males, mean age 77, range 54 to 90) from June 2005 to February 2007 immediately after endovascular treatment of thoracic and abdominal aortic aneurysms on the angiographic table. Nine thoracic aortic aneurysms were treated with Zenith trademark -endoprosthesis. Nine of twelve abdominal aortic aneurysms were treated with Zenith trademark -Endoprosthesis and three with an Excluder trademark -Endoprosthesis. Images were acquired with a rotating C-arm and the following parameters: during an acquisition time of 20 seconds and at a rotation of 217 degrees, 538 projections were acquired. Contrast agent was administered in 14 patients. Images were displayed in MIP, MPR and VRT mode. Results: in all patients the stentgraft was shown exactly and the alignment of the prosthesis along the landing zones was well displayed. The aneurismal sack was well shown in all patients. 1 x an endoleak II was detected, 1 x an angiographically verified endoleak I was not detected. In one patient distal extension was considered due to suspected short stentgraft at the distal neck. Flat-panel CT showed sufficient neck coverage and no extension was inserted. Due to artifacts of the prosthesis, the platinum markers and the guide wire as well as due to pulsation of the aorta, the resolution of detail decreased and reduced the visualization of the alignment. (orig.)

  16. Comparison between radiation exposure levels using an image intensifier and a flat-panel detector-based system in image-guided central venous catheter placement in children weighing less than 10 kg

    Energy Technology Data Exchange (ETDEWEB)

    Miraglia, Roberto; Maruzzelli, Luigi; Cortis, Kelvin; Gerasia, Roberta; Maggio, Simona; Luca, Angelo [Diagnostic and Therapeutic Services, Mediterranean Institute for Transplantation and Advanced Specialized Therapies (ISMETT), Palermo (Italy); Piazza, Marcello [Department of Anesthesia, Mediterranean Institute for Transplantation and Advanced Specialized Therapies (ISMETT), Palermo (Italy); Tuzzolino, Fabio [Department of Information Technology, Mediterranean Institute for Transplantation and Advanced Specialized Therapies (ISMETT), Palermo (Italy)

    2014-09-10

    Ultrasound-guided central venous puncture and fluoroscopic guidance during central venous catheter (CVC) positioning optimizes technical success and lowers the complication rates in children, and is therefore considered standard practice. The purpose of this study was to compare the radiation exposure levels recorded during CVC placement in children weighing less than 10 kg in procedures performed using an image intensifier-based angiographic system (IIDS) to those performed in a flat-panel detector-based interventional suite (FPDS). A retrospective review of 96 image-guided CVC placements, between January 2008 and October 2013, in 49 children weighing less than 10 kg was performed. Mean age was 8.2 ± 4.4 months (range: 1-22 months). Mean weight was 7.1 ± 2.7 kg (range: 2.5-9.8 kg). The procedures were classified into two categories: non-tunneled and tunneled CVC placement. Thirty-five procedures were performed with the IIDS (21 non-tunneled CVC, 14 tunneled CVC); 61 procedures were performed with the FPDS (47 non-tunneled CVC, 14 tunneled CVC). For non-tunneled CVC, mean DAP was 113.5 ± 126.7 cGy cm{sup 2} with the IIDS and 15.9 ± 44.6 cGy . cm{sup 2} with the FPDS (P < 0.001). For tunneled CVC, mean DAP was 84.6 ± 81.2 cGy . cm{sup 2} with the IIDS and 37.1 ± 33.5 cGy cm{sup 2} with the FPDS (P = 0.02). The use of flat-panel angiographic equipment reduces radiation exposure in small children undergoing image-guided CVC placement. (orig.)

  17. Selenium in bovine spermatozoa.

    Science.gov (United States)

    Niemi, S M; Kuzan, F B; Senger, P L

    1981-05-01

    This study investigated the association of selenium with ejaculated bovine spermatozoa. Over 75% of the radioactive spermatozoa. Over 75% of the radioactive selenium-75 was released after 30 min of incubation in 2 X 10(-3) dithiothreitol. Of the selenium-75 released by dithiothreitol, 85% was associated with spermatozoal protein. Protein containing selenium-75 was found predominantly in a single band after polyacrylamide gel electrophoresis. Molecular weight was approximately 21,500 daltons.

  18. Selenium and Human Health

    Directory of Open Access Journals (Sweden)

    M Abedi

    2013-04-01

    Full Text Available Introduction: Selenium is an essential element for human health and it is toxic at high concentrations. Selenium is a constituent component of selenoproteins that have enzymatic and structural roles in human biochemistry. Selenium is a best antioxidant and catalyst for production of thyroid hormone. This element has the key role in the immune function; prevention of AIDS progression and the deactivity of toxins. Furthermore, selenium is essential for sperm motility and can reduce abortions. Selenium deficiency was also associated with adverse mood states. The findings regarding cardiovascular disease risk related to selenium deficiency is unclear, though other conditions such as vascular inflammation, oxidative stress and selenium deficiency can cause this disease too. Moreover, consuming of 60 mg of selenium per day may be associated with reduction of cancer risk. In this study, a review of studies has been performed on the biochemical function of selenium toxicity, and its effects on human health. Furthermore, certain identified cancers associated with selenium have been discussed to absorb more attention to the status of this element and also as a guide for further studies. Selenium plays the dual character (useful and harmful in human health, and then it is necessary to determine the concentration of this element in body fluids and tissues. An appropriate method for routine measurement of selenium in clinical laboratories is electro thermal atomic absorption spectrometry (ETAAS with very low detection limit and good precision.

  19. Selenium in soil

    Directory of Open Access Journals (Sweden)

    Čuvardić Maja S.

    2003-01-01

    Full Text Available Selenium (Se is an essential microelement, necessary for normal functioning of human and animal organisms. Its deficiency in food and feed causes a number of diseases. In high concentrations, selenium is toxic for humans animals and plants. Soil provision with selenium affects its level in food and feed via nutrition chain. However, selenium reactivity and bioavailability depends not only on its total content in soil but also on its chemical forms. Distribution of the different forms of selenium depends on soil properties such as reaction, aeration, contents of clay and organic matter and microbiological activity.

  20. Selenium Adsorption To Aluminum-Based Water Treatment Residuals

    Science.gov (United States)

    Aluminum-based water treatment residuals (WTR) can adsorb water-and soil-borne P, As(V), As(III), and perchlorate, and may be able to adsorb excess environmental selenium. WTR, clay minerals, and amorphous aluminum hydroxide were shaken for 24 hours in selenate or selenite solut...

  1. Selenium cytotoxicity in cancer.

    Science.gov (United States)

    Wallenberg, Marita; Misra, Sougat; Björnstedt, Mikael

    2014-05-01

    Selenium is an essential trace element with growth-modulating properties. Decades of research clearly demonstrate that selenium compounds inhibit the growth of malignant cells in diverse experimental model systems. However, the growth-modulating and cytotoxic mechanisms are diverse and far from clear. Lately, a remarkable tumour selective cytotoxicity of selenium compounds has been shown, indicating the potential of selenium in the treatment of cancer. Of particular interest are the redox-active selenium compounds exhibiting cytotoxic potential to tumour cells. These selenium compounds elicit complex patterns of pharmacodynamics and pharmacokinetics, leading to cell death pathways that differ among compounds. Modern oncology often focuses on targeted ligand-based therapeutic strategies that are specific to their molecular targets. These drugs are initially efficient, but the tumour cells often rapidly develop resistance against these drugs. In contrast, certain redox-active selenium compounds induce complex cascades of pro-death signalling at pharmacological concentrations with superior tumour specificity. The target molecules are often the ones that are important for the survival of cancer cells and often implicated in drug resistance. Therefore, the chemotherapeutic applications of selenium offer great possibilities of multi-target attacks on tumour cells. This MiniReview focuses on the tumour-specific cytotoxic effects of selenium, with special emphasis on cascades of cellular events induced by the major groups of pharmacologically active selenium compounds. Furthermore, the great pharmacological potential of selenium in the treatment of resistant cancers is discussed.

  2. Image lag modeling and correction method for flat panel detector in cone-beam CT%锥束CT平板探测器成像的余晖建模与校正方法

    Institute of Scientific and Technical Information of China (English)

    黄魁东; 张定华; 李明君; 张华

    2013-01-01

    Cone-beam computed tomography (CT) has the notable features, viz high efficiency and high precision, and is widely used in the areas such as medical imaging and industrial non-destructive testing, but the presence of image lag reduces the quality of CT images. By referencing the multi-exponential decay model for the image lag and combining with the actual decay rule of the flat panel detector output signal, a new decay modeling and correction method for the image lag based on multi-exponential fitting is proposed. Firstly, an imaging experiment using cone-beam CT based on flat panel detector is carried out;the results show that the image lag decay of the pixels in the flat panel detector has a good consistency, and is irrelevant to the initial gray value. Then, the rapid image lag correction is achieved according to the image lag decay model, and the comparison of image quality of the projected images and slice images before and after image lag correction indicates that the edge sharpness of the part has been significantly improved after the lag correction. This method does not need to obtain the scintillation compositions and the decay time constants of the detector, and is easily applied to the practical cone-beam CT imaging systems for image lag detection and correction.%锥束CT具有高效率和高精度的显著特点,在医学成像与工业无损检测等领域已得到广泛应用,但余晖的存在降低了CT图像的质量。本文借鉴余晖多指数衰减模型的思想,结合平板探测器输出信号的实际衰减规律,提出了一种新的基于多指数拟合的余晖衰减建模及校正方法。首先进行了基于平板探测器的锥束CT成像实验,结果表明平板探测器各像素的余晖衰减规律具有良好的一致性,且余晖衰减规律与初始灰度的大小无关;其后根据建立的余晖衰减模型实现了余晖的快速校正,并分析比较了余晖校正前后投影图像和切片图像质量,

  3. Absorption, distribution, metabolism and excretion of selenium following oral administration of elemental selenium nanoparticles or selenite in rats

    DEFF Research Database (Denmark)

    Löschner, Katrin; Hadrup, Niels; Hansen, Marianne

    2014-01-01

    A suspension of nanoparticles of BSA-stabilized red amorphous elemental selenium (Se) or an aqueous solution of sodium selenite was repeatedly administered by oral gavage for 28 days at 0.05 mg/kg bw/day (low dose) or at 0.5 mg/kg bw/day (high dose) as Se to female rats. Prior to administration...

  4. Amorphous nanophotonics

    CERN Document Server

    Scharf, Toralf

    2013-01-01

    This book represents the first comprehensive overview over amorphous nano-optical and nano-photonic systems. Nanophotonics is a burgeoning branch of optics that enables many applications by steering the mould of light on length scales smaller than the wavelength with devoted nanostructures. Amorphous nanophotonics exploits self-organization mechanisms based on bottom-up approaches to fabricate nanooptical systems. The resulting structures presented in the book are characterized by a deterministic unit cell with tailored geometries; but their spatial arrangement is not controlled. Instead of periodic, the structures appear either amorphous or random. The aim of this book is to discuss all aspects related to observable effects in amorphous nanophotonic material and aspects related to their design, fabrication, characterization and integration into applications. The book has an interdisciplinary nature with contributions from scientists in physics, chemistry and materials sciences and sheds light on the topic fr...

  5. 不同结构的平板式阳台壁挂太阳能热水系统性能分析%Performance analysis of balcony hanging flat panel solar water heaters

    Institute of Scientific and Technical Information of China (English)

    高立峰; 孙艺霞; 张敏; 何茂涛; 杨荣昆

    2012-01-01

    We perform comparative tests for vertical and horizontal flow solar collectors. We further calculate and comparatively analyze the heat performance of these two water heaters. Results show that the horizontal flat panel solar water heater is superior to the vertical one in instantaneous efficiency, average daily efficiency, daily useful energy and warming performance.%针对竖直式和水平式两种流道结构的集热器进行对比试验,根据相关参数对两种热水系统的热性能进行了计算和对比分析,结果表明水平式流道的平板热水系统在瞬时效率、El平均效率、El有用得热量和升温性能4个方面均优于竖直式流道的平板太阳能热水系统。

  6. Semiautomatic Landmark-Based Two-Dimensional—Three-Dimensional Image Fusion in Living Mice: Correlation of Near-Infrared Fluorescence Imaging of Cy5.5-Labeled Antibodies with Flat-Panel Volume Computed Tomography

    Directory of Open Access Journals (Sweden)

    Christian Dullin

    2009-01-01

    Full Text Available Connecting fluorescence signals with anatomic structures enhances our ability to monitor biologic processes in mice. Here, we present a semiautomated approach to correlate two-dimensional (2D noninvasive near-infrared fluorescence (NIRF imaging with three-dimensional (3D, high-resolution, flat-panel volume computed tomography (fpVCT. We developed an algorithm to colocalize fluorescence signals of NIRF-labeled antibodies directed against matriptase and urokinase plasminogen activator receptor (uPAR to orthotopic carcinomas in mice visualized by fpVCT. For this purpose, mice were anesthetized and fixed on a multimodality animal bed containing fiducial markers filled with iodine-containing contrast agent and fluorescent dye. After intravenous administration of contrast agent and Cy5.5-labeled antibodies, NIRF and fpVCT images were obtained, without repositioning the mice. Binding of Cy5.5-labeled matriptase-specific antibody to pancreatic tumors and Cy5.5-labeled uPAR-specific antibody to mammary carcinomas was assessed by time-domain NIRF imaging measuring the location of fluorescence intensity and its lifetime. In summary, we developed a novel 2D-3D registration technique for image fusion with NIRF imaging and fpVCT to provide complementary information in tumor models on the in vivo association of functional information with anatomic structures. The combination of fpVCT with NIRF imaging will now allow targeted and effective monitoring of preclinical tumor therapies.

  7. Selenium in edible mushrooms.

    Science.gov (United States)

    Falandysz, Jerzy

    2008-01-01

    Selenium is vital to human health. This article is a compendium of virtually all the published data on total selenium concentrations, its distribution in fruitbody, bioconcentration factors, and chemical forms in wild-grown, cultivated, and selenium-enriched mushrooms worldwide. Of the 190 species reviewed (belonging to 21 families and 56 genera), most are considered edible, and a few selected data relate to inedible mushrooms. Most of edible mushroom species examined until now are selenium-poor (cesarea, A. campestris, A. edulis, A. macrosporus, and A. silvaticus. A particularly rich source of selenium could be obtained from selenium-enriched mushrooms that are cultivated on a substrate fortified with selenium (as inorganic salt or selenized-yeast). The Se-enriched Champignon Mushroom could contain up to 30 or 110 microg Se/g dw, while the Varnished Polypore (Ganoderma lucidum) could contain up to 72 microg Se/g dw. An increasingly growing database on chemical forms of selenium of mushrooms indicates that the seleno-compounds identified in carpophore include selenocysteine, selenomethionine, Se-methylselenocysteine, selenite, and several unidentified seleno-compounds; their proportions vary widely. Some aspects of environmental selenium occurrence and human body pharmacokinetics and nutritional needs will also be briefly discussed in this review.

  8. Increase of brightness and transmission efficiency in flat panel display through serial synchronous scanning mode with double buffers%串行同步双缓冲扫描提高平板显示器的显示亮度和传送利用率

    Institute of Scientific and Technical Information of China (English)

    陈章进; 陈峰; 冉峰; 徐美华; 郑方

    2007-01-01

    This paper presents a serial synchronous scanning mode in flat panel display(FPD)by adding a latch buffer between the seriaiizer and the driving buffer.Comparing with conventional techniques,the proposed structure can efficiently reduce the brightness loss and improve the transmission performance.Theoretical analysis and experimental results show that the ratio between the lightest weight display time and the relative transmission time is a tradeoff between brightness loss and transmission efficiency.

  9. Swedish views on selenium.

    Science.gov (United States)

    Bruce, A

    1986-01-01

    For a long time selenium was known only for its toxic characteristics. During the last few decades selenium deficiency has been recognized as an important agricultural problem in Sweden. On average, grains and pastures only contain one tenth of the amount of selenium considered necessary to avoid symptoms of deficiency. However, the incidence of muscle degeneration among the animals has been low, probably due to imported animal feed. Since 1980 selenium has been added to animal feed, but only minor changes in the selenium content of Swedish food stuffs have been recorded. Some studies have shown that the average Swedish dietary intake of selenium is 10-70 micrograms/day. The lowest levels were found in vegan diets, based on locally-grown products. Swedish studies have found depressed glutathione peroxidase (GSH-Px) levels in patients with various skin disorders, including acne; myotonic dystrophy and rheumatic arthritis. Clinical trials with selenium supplementation have given positive results in some of these disorders as well as in some patients with disabling muscular and joint pains. Today there is a large sale of selenium tablets sometimes with additional vitamin E. The marketing of these tablets, however, is often based on unsubstantiated claims.

  10. 平板DR数字成像技术在焊管行业中的应用%Application of Flat Panel Digital Radiography Imaging Technology in Welded Pipe Industry

    Institute of Scientific and Technical Information of China (English)

    王长安; 余国民; 魏雅博

    2014-01-01

    In this article, it introduced the working principle of digital radiography(DR) imaging technology and its application in welded pipe industry. Compared with the detection effect of traditional X-ray industrial TV from sensitivity detection, image resolution, residual magnetization, radiation dose etc. The result showed that the flat panel DR imaging technology is with some advantages, such as high sensitivity of detection, high efficiency, low labour tension, little doses of radiation and so on. It ensures the weld quality, greatly reduces the accident rate of pipeline, and can replace X-ray industrial TV detecting technology. At present, this technology is widely applied in welded pipe industry.%介绍了DR数字成像技术的工作原理及其在焊管行业检测中的应用。在灵敏度检测、图像分辨率、剩磁影响和辐射剂量等方面与传统的X射线工业电视的检测效果进行了比较分析。结果表明, DR数字成像技术具有检测灵敏度和检测效率较高、劳动强度小、辐射剂量小等优点,保证了焊缝质量,大大降低了管线的事故发生率,可以替代传统X射线工业电视检测技术在焊管行业的应用。

  11. Flat-Panel Cone-Beam Ct-Guided Radiofrequency Ablation of Very Small (≤1.5 cm) Liver Tumors: Technical Note on a Preliminary Experience

    Energy Technology Data Exchange (ETDEWEB)

    Cazzato, Roberto Luigi, E-mail: r.cazzato@unicampus.it; Buy, Xavier, E-mail: x.buy@bordeaux.unicancer.fr; Alberti, Nicolas, E-mail: nicoalbertibdx@gmail.com; Fonck, Mariane, E-mail: m.fonk@bordeaux.unicancer.fr [Institut Bergonié 229 Cours de l’Argonne, Department of Radiology (France); Grasso, Rosario Francesco, E-mail: r.grasso@unicampus.it [Università “Campus Bio-Medico di Roma”, Department of Radiology and Diagnostic Imaging (Italy); Palussière, Jean, E-mail: j.palussiere@bordeaux.unicancer.fr [Institut Bergonié 229 Cours de l’Argonne, Department of Radiology (France)

    2015-02-15

    PurposeThe aim of the present study was to investigate the technical feasibility of flat-panel cone-beam CT (CBCT)-guided radiofrequency ablation (RFA) of very small (<1.5 cm) liver tumors.Materials and MethodsPatients included were candidates for hepatic percutaneous RFA as they had single biopsy-proven hepatic tumors sized ≤1.5 cm and poorly defined on ultrasonography. Following apnea induction, unenhanced CBCT scans were acquired and used to deploy the RF electrode with the aid of a virtual navigation system. If the tumor was not clearly identified on the unenhanced CBCT scan, a right retrograde arterial femoral access was established to carry out hepatic angiography and localize the tumor. Patients’ lesions and procedural variables were recorded and analyzed.ResultsThree patients (2 male and 1 female), aged 68, 76, and 87 years were included; 3 lesions (2 hepato-cellular carcinoma and 1 metastasis from colorectal cancer) were treated. One patient required hepatic angiography. Cycles of apnea used to acquire CBCT images and to deploy the electrode lasted <120 s. Mean fluoroscopic time needed to deploy the electrode was 36.6 ± 5.7 min. Mean overall procedural time was 66.0 ± 22.9 min. No peri- or post-procedural complications were noted. No cases of incomplete ablation were noted at 1-month follow-up.ConclusionPercutaneous CBCT-guided liver RFA with or without arterial hepatic angiography is technically feasible.

  12. A study on 100 MeV O{sup 7+} irradiated SnO{sub 2}/Ag/SnO{sub 2} multilayer as transparent electrode for flat panel display application

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Vikas [Department of Physics, Malaviya National Institute of Technology, Jaipur 302017 (India); Singh, Satyavir, E-mail: satyavir84@gmail.com [Department of Physics, Malaviya National Institute of Technology, Jaipur 302017 (India); Asokan, K. [Inter-University Accelerator Centre, Aruna Asaf Ali Road, New Delhi 110067 (India); Sachdev, Kanupriya [Department of Physics, Malaviya National Institute of Technology, Jaipur 302017 (India); Materials Research Centre, Malaviya National Institute of Technology, Jaipur 302017 India (India)

    2016-07-15

    The multilayer thin films of SnO{sub 2}/Ag/SnO{sub 2} were deposited using electron-beam and thermal evaporation for flat panel display application. The as-prepared SnO{sub 2}/Ag/SnO{sub 2} specimen was irradiated with 100 MeV O{sup 7+} ions by varying the fluences 1 × 10{sup 12} and 5 × 10{sup 12} ions/cm{sup 2}. The pristine and irradiated films were investigated using XRD, SEM, AFM and Raman to find out modification in the structure and surface morphology of the films. UV–Vis and Hall measurement techniques were used to investigate the optical and electrical properties respectively. It was observed that the roughness of the film after irradiation (for the fluence of 1 × 10{sup 12} ions/cm{sup 2}) ​ decreased to 0.68 nm from 1.6 nm and showed an increase in roughness to 1.35 nm on increasing the fluence to 5 × 10{sup 12} ions/cm{sup 2}. This oxide/metal/oxide structure fulfills the basic requirements of a TCE, like high-transmittance >75% for pristine and >80% for the fluence of 1 × 10{sup 12} ions/cm{sup 2} over a broad spectrum of visible light for practical applications. The multilayer structure shows change in the electrical resistivity from 1.6 × 10{sup −3} Ω cm to 6.3 × 10{sup −3} Ω cm after irradiation.

  13. Flat panel display characterization: a perceptual approach

    NARCIS (Netherlands)

    Teunissen, C.

    2009-01-01

    Over the last decade, consumer television sets have substantially increased in screen size, with screen diagonals up to 65-inch and beyond. At the same time, their thickness has decreased to only a few centimeters. Right from the start, this combination has been highly appreciated by consumers, resu

  14. Software Simulates Sight: Flat Panel Mura Detection

    Science.gov (United States)

    2008-01-01

    In the increasingly sophisticated world of high-definition flat screen monitors and television screens, image clarity and the elimination of distortion are paramount concerns. As the devices that reproduce images become more and more sophisticated, so do the technologies that verify their accuracy. By simulating the manner in which a human eye perceives and interprets a visual stimulus, NASA scientists have found ways to automatically and accurately test new monitors and displays. The Spatial Standard Observer (SSO) software metric, developed by Dr. Andrew B. Watson at Ames Research Center, measures visibility and defects in screens, displays, and interfaces. In the design of such a software tool, a central challenge is determining which aspects of visual function to include while accuracy and generality are important, relative simplicity of the software module is also a key virtue. Based on data collected in ModelFest, a large cooperative multi-lab project hosted by the Optical Society of America, the SSO simulates a simplified model of human spatial vision, operating on a pair of images that are viewed at a specific viewing distance with pixels having a known relation to luminance. The SSO measures the visibility of foveal spatial patterns, or the discriminability of two patterns, by incorporating only a few essential components of vision. These components include local contrast transformation, a contrast sensitivity function, local masking, and local pooling. By this construction, the SSO provides output in units of "just noticeable differences" (JND) a unit of measure based on the assumed smallest difference of sensory input detectable by a human being. Herein is the truly amazing ability of the SSO, while conventional methods can manipulate images, the SSO models human perception. This set of equations actually defines a mathematical way of working with an image that accurately reflects the way in which the human eye and mind behold a stimulus. The SSO is intended for a wide variety of applications, such as evaluating vision from unmanned aerial vehicles, measuring visibility of damage to aircraft and to the space shuttles, predicting outcomes of corrective laser eye surgery, inspecting displays during the manufacturing process, estimating the quality of compressed digital video, evaluating legibility of text, and predicting discriminability of icons or symbols in a graphical user interface.

  15. Selenium for preventing cancer

    Directory of Open Access Journals (Sweden)

    Gabriele Dennert

    Full Text Available BACKGROUND: Selenium is a trace element essential to humans. Higher selenium exposure and selenium supplements have been suggested to protect against several types of cancers. OBJECTIVE: Two research questions were addressed in this review: What is the evidence for: 1. an aetiological relationship between selenium exposure and cancer risk in women and men?; 2. the efficacy of selenium supplementation for cancer prevention in women and men? SEARCH STRATEGY: We searched electronic databases and bibliographies of reviews and included publications. SELECTION CRITERIA: We included prospective observational studies to answer research question (a and randomised controlled trials (RCTs to answer research question (b. DATA COLLECTION AND ANALYSIS: We conducted random effects meta-analyses of epidemiological data when five or more studies were retrieved for a specific outcome. We made a narrative summary of data from RCTs. MAIN RESULTS: We included 49 prospective observational studies and six RCTs. In epidemiologic data, we found a reduced cancer incidence (summary odds ratio, OR, 0.69; 95% confidence interval, CI, 0.53 to 0.91 and mortality (OR 0.55, 95% CI 0.36 to 0.83 with higher selenium exposure. Cancer risk was more pronouncedly reduced in men (incidence: OR 0.66, 95% CI 0.42 to 1.05 than in women (incidence: OR 0.90, 95% CI 0.45 to 1.77. These findings have potential limitations due to study design, quality and heterogeneity of the data, which complicated the interpretation of the summary statistics. The RCTs found no protective efficacy of selenium yeast supplementation against non-melanoma skin cancer or L-selenomethionine supplementation against prostate cancer. Study results for the prevention of liver cancer with selenium supplements were inconsistent and studies had an unclear risk of bias. The results of the Nutritional Prevention of Cancer Trial (NPCT and SELECT raised concerns about possible harmful effects of selenium supplements. AUTHORS

  16. Why Nature Chose Selenium.

    Science.gov (United States)

    Reich, Hans J; Hondal, Robert J

    2016-04-15

    The authors were asked by the Editors of ACS Chemical Biology to write an article titled "Why Nature Chose Selenium" for the occasion of the upcoming bicentennial of the discovery of selenium by the Swedish chemist Jöns Jacob Berzelius in 1817 and styled after the famous work of Frank Westheimer on the biological chemistry of phosphate [Westheimer, F. H. (1987) Why Nature Chose Phosphates, Science 235, 1173-1178]. This work gives a history of the important discoveries of the biological processes that selenium participates in, and a point-by-point comparison of the chemistry of selenium with the atom it replaces in biology, sulfur. This analysis shows that redox chemistry is the largest chemical difference between the two chalcogens. This difference is very large for both one-electron and two-electron redox reactions. Much of this difference is due to the inability of selenium to form π bonds of all types. The outer valence electrons of selenium are also more loosely held than those of sulfur. As a result, selenium is a better nucleophile and will react with reactive oxygen species faster than sulfur, but the resulting lack of π-bond character in the Se-O bond means that the Se-oxide can be much more readily reduced in comparison to S-oxides. The combination of these properties means that replacement of sulfur with selenium in nature results in a selenium-containing biomolecule that resists permanent oxidation. Multiple examples of this gain of function behavior from the literature are discussed.

  17. Selenium adsorption to aluminum-based water treatment residuals

    Energy Technology Data Exchange (ETDEWEB)

    Ippolito, James A.; Scheckel, Kirk G.; Barbarick, Ken A.; (US-Agriculture); (EPA); (CSU)

    2009-09-02

    Aluminum-based water treatment residuals (WTR) can adsorb water- and soil-borne P, As(V), As(III), and perchlorate, and may be able to adsorb excess environmental selenium. WTR, clay minerals, and amorphous aluminum hydroxide were shaken for 24 h in selenate or selenite solutions at pH values of 5-9, and then analyzed for selenium content. Selenate and selenite adsorption edges were unaffected across the pH range studied. Selenate adsorbed on to WTR, reference mineral phases, and amorphous aluminum hydroxide occurred as outer sphere complexes (relatively loosely bound), while selenite adsorption was identified as inner-sphere complexation (relatively tightly bound). Selenite sorption to WTR in an anoxic environment reduced Se(IV) to Se(0), and oxidation of Se(0) or Se(IV) appeared irreversible once sorbed to WTR. Al-based WTR could play a favorable role in sequestering excess Se in affected water sources.

  18. Selenium in diet

    Science.gov (United States)

    ... needed. Selenium may help: Prevent certain cancers Prevent cardiovascular disease Protect the body from the poisonous effects of ... intakes of healthy people. How much of each vitamin you need depends on your age and gender. ...

  19. Modelling and structure optimization of flat-panel thermal concentrated solar thermoelectric device∗%平板集热太阳热电器件建模及结构优化

    Institute of Scientific and Technical Information of China (English)

    刘磊†; 张锁良; 马亚坤; 吴国浩; 郑树凯; 王永青

    2013-01-01

    Solar thermoelectric conversion is another way to convert solar radiation directly into electricity besides photovoltaic technology, and has become a new hot spot of solar energy utilization in recent years. In this paper a model of flat-panel thermal concentrated solar thermoelectric device is built based on the material of Bi2Te3. And finite element analysis is used to analyze the temperature distribution of the device under AM1.5 illumination. Furthermore, the influences of thermal concentration, cross section area and length of thermal legs on open voltage, maximum output power and conversion efficiency of the device are calculated based on temperature-dependent physical parameters. The results indicate that thermal concentration and length of thermal legs haved a significant influence on device performance, while the cross section area changes the conversion efficiency of device relatively weakly, and the conversion efficiency of the device reaches 1.56%in this model.%  太阳能热电转换是光伏效应外另一种直接将太阳辐射转变为电能的途径,近年来已经成为太阳能利用的热点之一.本文以Bi2Te3材料为基础构建平板集热太阳热电器件模型,采用有限元法分析AM1.5辐射条件下器件温度分布情况,并结合基于温度的物性参数计算集热比、热臂截面积与长度变化等因素对器件的开路电压、最大输出功率及转化效率的影响.研究发现:集热比与热臂长度的变化对器件性能有显著影响,热臂截面积的变化对器件转化效率影响相对较弱;在这一模型中,平板集热太阳热电器件的转化效率达到1.56%.

  20. SU-E-I-53: Comparison of Kerma-Area-Product Between the Micro-Angiographic Fluoroscope (MAF) and a Flat Panel Detector (FPD) as Used in Neuro-Endovascular Procedures

    Energy Technology Data Exchange (ETDEWEB)

    Vijayan, S; Rana, V; Nagesh, S Setlur; Xiong, Z; Rudin, S; Bednarek, D [Toshiba Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY (United States)

    2015-06-15

    Purpose: To determine the reduction of integral dose to the patient when using the micro-angiographic fluoroscope (MAF) compared to when using the standard flat-panel detector (FPD) for the techniques used during neurointerventional procedures. Methods: The MAF is a small field-of-view, high resolution x-ray detector which captures 1024 x 1024 pixels with an effective pixel size of 35μm and is capable of real-time imaging up to 30 frames per second. The MAF was used in neuro-interventions during those parts of the procedure when high resolution was needed and the FPD was used otherwise. The technique parameters were recorded when each detector was used and the kerma-area-product (KAP) per image frame was determined. KAP values were calculated for seven neuro interventions using premeasured calibration files of output as a function of kVp and beam filtration and included the attenuation of the patient table for the frontal projections to be more representative of integral patient dose. The air kerma at the patient entrance was multiplied by the beam area at that point to obtain the KAP values. The ranges of KAP values per frame were determined for the range of technique parameters used during the clinical procedures. To appreciate the benefit of the higher MAF resolution in the region of interventional activity, DA technique parameters were generally used with the MAF. Results: The lowest and highest values of KAP per frame for the MAF in DA mode were 4 and 50 times lower, respectively, compared to those of the FPD in pulsed fluoroscopy mode. Conclusion: The MAF was used in those parts of the clinical procedures when high resolution and image quality was essential. The integral patient dose as represented by the KAP value was substantially lower when using the MAF than when using the FPD due to the much smaller volume of tissue irradiated. This research was supported in part by Toshiba Medical Systems Corporation and NIH Grant R01EB002873.

  1. SU-D-204-05: Quantitative Comparison of a High Resolution Micro-Angiographic Fluoroscopic (MAF) Detector with a Standard Flat Panel Detector (FPD) Using the New Metric of Generalized Measured Relative Object Detectability (GM-ROD)

    Energy Technology Data Exchange (ETDEWEB)

    Russ, M; Ionita, C; Bednarek, D; Rudin, S [Toshiba Stroke and Vascular Research Center, University at Buffalo (SUNY), Buffalo, NY (United States)

    2015-06-15

    Purpose: In endovascular image-guided neuro-interventions, visualization of fine detail is paramount. For example, the ability of the interventionist to visualize the stent struts depends heavily on the x-ray imaging detector performance. Methods: A study to examine the relative performance of the high resolution MAF-CMOS (pixel size 75µm, Nyquist frequency 6.6 cycles/mm) and a standard Flat Panel Detector (pixel size 194µm, Nyquist frequency 2.5 cycles/mm) detectors in imaging a neuro stent was done using the Generalized Measured Relative Object Detectability (GM-ROD) metric. Low quantum noise images of a deployed stent were obtained by averaging 95 frames obtained by both detectors without changing other exposure or geometric parameters. The square of the Fourier transform of each image is taken and divided by the generalized normalized noise power spectrum to give an effective measured task-specific signal-to-noise ratio. This expression is then integrated from 0 to each of the detector’s Nyquist frequencies, and the GM-ROD value is determined by taking a ratio of the integrals for the MAF-CMOS to that of the FPD. The lower bound of integration can be varied to emphasize high frequencies in the detector comparisons. Results: The MAF-CMOS detector exhibits vastly superior performance over the FPD when integrating over all frequencies, yielding a GM-ROD value of 63.1. The lower bound of integration was stepped up in increments of 0.5 cycles/mm for higher frequency comparisons. As the lower bound increased, the GM-ROD value was augmented, reflecting the superior performance of the MAF-CMOS in the high frequency regime. Conclusion: GM-ROD is a versatile metric that can provide quantitative detector and task dependent comparisons that can be used as a basis for detector selection. Supported by NIH Grant: 2R01EB002873 and an equipment grant from Toshiba Medical Systems Corporation.

  2. A comparison between magnetic resonance angiography at 3 teslas (time-of-flight and contrast-enhanced and flat-panel digital subtraction angiography in the assessment of embolized brain aneurysms

    Directory of Open Access Journals (Sweden)

    Guilherme S. Nakiri

    2011-01-01

    Full Text Available PURPOSE: To compare the time-of-flight and contrast-enhanced- magnetic resonance angiography techniques in a 3 Tesla magnetic resonance unit with digital subtraction angiography with the latest flat-panel technology and 3D reconstruction in the evaluation of embolized cerebral aneurysms. INTRODUCTION: Many embolized aneurysms are subject to a recurrence of intra-aneurismal filling. Traditionally, imaging surveillance of coiled aneurysms has consisted of repeated digital subtraction angiography. However, this method has a small but significant risk of neurological complications, and many authors have advocated the use of noninvasive imaging methods for the surveillance of embolized aneurysms. METHODS: Forty-three aneurysms in 30 patients were studied consecutively between November 2009 and May 2010. Two interventional neuroradiologists rated the time-of-flight-magnetic resonance angiography, the contrast-enhanced-magnetic resonance angiography, and finally the digital subtraction angiography, first independently and then in consensus. The status of aneurysm occlusion was assessed according to the Raymond scale, which indicates the level of recanalization according to degrees: Class 1: excluded aneurysm; Class 2: persistence of a residual neck; Class 3: persistence of a residual aneurysm. The agreement among the analyses was assessed by applying the Kappa statistic. RESULTS: Inter-observer agreement was excellent for both methods (K = 0.93; 95 % CI: 0.84-1. Inter-technical agreement was almost perfect between time-of-flight-magnetic resonance angiography and digital subtraction angiography (K = 0.98; 95 % CI: 0.93-1 and between time-of-flight-magnetic resonance angiography and contrast-enhanced-magnetic resonance angiography (K = 0.98; 95% CI: 0.93-1. Disagreement occurred in only one case (2.3%, which was classified as Class I by time-of-flight-magnetic resonance angiography and Class II by digital subtraction angiography. The agreement between

  3. In vivo synthesis of nano-selenium by Tetrahymena thermophila SB210.

    Science.gov (United States)

    Cui, Yin-Hua; Li, Ling-Li; Zhou, Nan-Qing; Liu, Jing-Hua; Huang, Qing; Wang, Hui-Juan; Tian, Jie; Yu, Han-Qing

    2016-12-01

    Nano-selenium has a great potential to be used in chemical, biological, medical and environmental fields. Biological methods for nano-selenium synthesis have attracted wide interests, because they can be operated at ambient temperature and pressure without complicated equipments. In this work, a protozoa, Tetrahymena thermophila (T. thermophila) SB210, was used to in vivo synthesize nano-selenium. The biosynthesized nano-selenium was characterized using transmission electron microscopy, energy dispersive X-ray spectroscopy and Raman spectroscopy. The synthesized amorphous spherical selenium nanoparticles had diameters of 50-500nm with the coexistence of irregular nano-selenium. The expressions of glutathione (GSH) synthesis related gene glutathione synthase, cysteine-rich protein metallothionein related gene metallothionein-1 and [2Fe-2S] cluster-binding protein related gene were up-regulated in the nano-selenium producing group. Also, the subsequent GSH detection and in vitro synthesis experimental results suggest the three proteins were likely to be involved in the nano-selenium synthesis process.

  4. 无线平板探测器在四肢小关节X线摄影中的临床应用%Clinical Application of Wireless Flat-panel Detector in X-ray Photography in the Small Joints of the Limbs

    Institute of Scientific and Technical Information of China (English)

    吴慧钊; 张泽坤; 吴文娟

    2013-01-01

    Purpose To compare the wireless flat-panel detector with gadolinium oxide coating in X-ray photography in the small joints of the limbs compared with conventional flat panel detector with cesium iodide coating. Materials and Methods Comparison was randomly performed between gadolinium oxide coated sulfur wireless flat-panel detector and cesium iodide coated conventional flat-panel detector for 80 patients who received routine X-ray photography, and scoring data were applied with statistical analysis. Results There was no significant difference between the scoring data from two film-reading people (P>0.05). The resolution of anatomical structure of small joint of limbs and tube current showed no significant difference for two types of imaging systems (P>0.05). Conclusion Wireless flat panel detector sulfur with gadolinium oxide coatings can obtain satisfactory image quality at a reasonable inspection doses in the X-ray photography of small joint of limbs. The imaging quality and inspection doses are similar to conventional flat panel detector device with cesium iodide coating, but the posture is more convenient.%目的对硫氧化钆涂层的无线平板探测器与碘化铯涂层的常规平板探测器进行对比,探讨硫氧化钆涂层的无线平板探测器在四肢小关节X线摄影中的应用价值。资料与方法80例行四肢小关节X线摄影患者随机分别使用硫氧化钆涂层的无线平板探测器和碘化铯涂层的常规平板探测器进行检查,对评分数据进行统计学分析。结果2名阅片人评分比较差异无统计学意义(P>0.05)。两种成像系统的四肢小关节解剖结构的显示清晰度差异无统计学意义(P>0.05)。两种成像系统管电流值的差异无统计学意义(P>0.05)。结论在合理的检查剂量下,硫氧化钆涂层的无线平板探测器应用于四肢小关节X线摄影可以获得较满意的图像质量,其成像质量和检查剂量近似于碘化铯涂层

  5. Biological selenium removal from wastewaters

    NARCIS (Netherlands)

    Lenz, M.

    2008-01-01

    In this thesis, microbial conversion of water-soluble, highly toxic forms of selenium (selenate, selenite) to less bioavailable elemental selenium was investigated. By the exploitation of different groups of microorganisms (selenium-respiring, nitrate-reducing and sulfate-reducing bacteria, methanog

  6. Selenium in human mammary carcinogenesis

    DEFF Research Database (Denmark)

    Overvad, Kim; Grøn, P.; Langhoff, Otto;

    1991-01-01

    /l and TNM stage II 76 +/- 13 micrograms selenium/l), indicating disease-mediated changes. The evaluation of selenium as a risk indicator in human breast cancer was therefore restricted to TNM stage I patients (n = 36). Multiple logistic regression analyses including variables associated with selenium levels...... revealed no association between selenium levels and breast cancer risk.......In a case-referent study on the possible role of selenium in human mammary carcinogenesis, serum selenium was found to be 79 +/- 12 micrograms/l in 66 cases and 81 +/- 12 micrograms/l in 93 referents. An internal trend in serum selenium was observed among cases (TNM stage I 81 +/- 11 micrograms...

  7. Electrons and phonons in amorphous semiconductors

    Science.gov (United States)

    Prasai, Kiran; Biswas, Parthapratim; Drabold, D. A.

    2016-07-01

    The coupling between lattice vibrations and electrons is one of the central concepts of condensed matter physics. The subject has been deeply studied for crystalline materials, but far less so for amorphous and glassy materials, which are among the most important for applications. In this paper, we explore the electron-lattice coupling using current tools of a first-principles computer simulation. We choose three materials to illustrate the phenomena: amorphous silicon (a-Si), amorphous selenium (a-Se) and amorphous gallium nitride (a-GaN). In each case, we show that there is a strong correlation between the localization of electron states and the magnitude of thermally induced fluctuations in energy eigenvalues obtained from the density-functional theory (i.e. Kohn-Sham eigenvalues). We provide a heuristic theory to explain these observations. The case of a-GaN, a topologically disordered partly ionic insulator, is distinctive compared to the covalent amorphous examples. Next, we explore the consequences of changing the charge state of a system as a proxy for tracking photo-induced structural changes in the materials. Where transport is concerned, we lend insight into the Meyer-Neldel compensation rule and discuss a thermally averaged Kubo-Greenwood formula as a means to estimate electrical conductivity and especially its temperature dependence. We close by showing how the optical gap of an amorphous semiconductor can be computationally engineered with the judicious use of Hellmann-Feynman forces (associated with a few defect states) using molecular dynamics simulations. These forces can be used to close or open an optical gap, and identify a structure with a prescribed gap. We use the approach with plane-wave density functional methods to identify a low-energy amorphous phase of silicon including several coordination defects, yet with a gap close to that of good quality a-Si models.

  8. Biomarkers of selenium status

    Science.gov (United States)

    The essential trace element selenium (Se) has multiple biological activities, which depend on the level of Se intake. Relatively low Se intakes determine the expression of selenoenzymes in which it serves as an essential constituent. Higher intakes have been shown to have anti-tumorigenic potentia...

  9. Selenium in mammalian spermiogenesis.

    Science.gov (United States)

    Flohé, Leopold

    2007-10-01

    The role of selenium in male fertility is reviewed with special emphasis on selenoprotein P and phospholipid hydroperoxide glutathione peroxidase (GPx4) in spermiogenesis. Inverse genetics reveal that selenoprotein P is required for selenium supply to the testis. GPx4 is abundantly synthesized in spermatids. As a moonlighting protein it is transformed in the later stages of spermiogenesis from an active selenoperoxidase into a structural protein that becomes a constituent of the mitochondrial sheath of spermatozoa. The transformation is paralleled by loss of glutathione. Mechanistically, the process is an alternate substrate inactivation of GPx4 resulting from reactions of its selenenic form with thiols of GPx4 itself and other proteins. Circumstantial evidence and ongoing experimental genetics indicate that the mitochondrially expressed form of the GPx4 gene is the most relevant one in spermiogenesis, with the nuclear form being dispensable for fertility and the role of cytosolic GPx4 remaining unclear. Clinical data reveal a strong association of low sperm GPx4 with infertility. Thus, impaired GPx4 biosynthesis, due to selenium deficiency or to genetic defects in gpx4 itself or in proteins involved in Se distribution and selenoprotein biosynthesis, causes male infertility, but can also be an epiphenomenon due to any perturbation of testicular function.

  10. Selenium accumulation in lettuce germplasm

    Science.gov (United States)

    Selenium (Se) is an essential micronutrient for animals and humans. Increasing Se content in food crops offers an effective approach to reduce the widespread selenium deficiency problem in many parts of the world. In this study, we evaluated thirty diverse accessions of lettuce (Lactuca sativa L.) f...

  11. Reduction of selenite by Azospirillum brasilense with the formation of selenium nanoparticles.

    Science.gov (United States)

    Tugarova, Anna V; Vetchinkina, Elena P; Loshchinina, Ekaterina A; Burov, Andrei M; Nikitina, Valentina E; Kamnev, Alexander A

    2014-10-01

    The ability to reduce selenite (SeO(3)(2-)) ions with the formation of selenium nanoparticles was demonstrated in Azospirillum brasilense for the first time. The influence of selenite ions on the growth of A. brasilense Sp7 and Sp245, two widely studied wild-type strains, was investigated. Growth of cultures on both liquid and solid (2 % agar) media in the presence of SeO(3)(2-) was found to be accompanied by the appearance of the typical red colouration. By means of transmission electron microscopy (TEM), electron energy loss spectroscopy (EELS) and X-ray fluorescence analysis (XFA), intracellular accumulation of elementary selenium in the form of nanoparticles (50 to 400 nm in diameter) was demonstrated for both strains. The proposed mechanism of selenite-to-selenium (0) reduction could involve SeO(3)(2-) in the denitrification process, which has been well studied in azospirilla, rather than a selenite detoxification strategy. The results obtained point to the possibility of using Azospirillum strains as endophytic or rhizospheric bacteria to assist phytoremediation of, and cereal cultivation on, selenium-contaminated soils. The ability of A. brasilense to synthesise selenium nanoparticles may be of interest to nanobiotechnology for "green synthesis" of bioavailable amorphous red selenium nanostructures.

  12. Biocompatibility selenium nanoparticles with an intrinsic oxidase-like activity

    Science.gov (United States)

    Guo, Leilei; Huang, Kaixun; Liu, Hongmei

    2016-03-01

    Selenium nanoparticles (SeNPs) are considered to be the new selenium supplement forms with high biological activity and low toxicity; however, the molecular mechanism by which SeNPs exert the biological function is unclear. Here, we reported that biocompatibility SeNPs possessed intrinsic oxidase-like activity. Using Na2SeO3 as a precursor and glutathione as a reductant, biocompatibility SeNPs were synthesized by the wet chemical reduction method in the presence of bovine serum albumin (BSA). The results of structure characterization revealed that synthesized SeNPs were amorphous red elementary selenium with spherical morphology, and ranged in size from 25 to 70 nm size with a narrow distribution (41.4 ± 6.7 nm). The oxidase-like activity of the as-synthesized SeNPs was tested with 3,3',5,5'-tetramethylbenzidine (TMB) as a substrate. The results indicated that SeNPs could catalyze the oxidization of TMB by dissolved oxygen. These SeNPs showed an optimum catalytic activity at pH 4 and 30 °C, and the oxidase-like activity was higher as the concentration of SeNPs increased and the size of SeNPs decreased. The Michaelis constant ( K m) values and maximal reaction velocity ( V max) of the SeNPs for TMB oxidation were 0.0083 mol/L and 3.042 μmol/L min, respectively.

  13. [Amorphization in pharmaceutical technology].

    Science.gov (United States)

    Révész, Piroska; Laczkovich, Orsolya; Eros, István

    2004-01-01

    The amorphization of crystalline active ingredients may be necessary because of the polymorphism of the active substance, the poor water-solubility of the drug material, difficult processing in the crystalline form and the taking out of a patent for a new (amorphous) form. This article introduces protocols for amorphization, which use methods traditionally applied in pharmaceutical technology. The protocols involve three possible routes: solvent methods, hot-melt technologies and milling procedures. With this presentation, the authors suggest help for practising experts to find the correct amorphization method.

  14. The nutritional selenium status of healthy Greeks.

    Science.gov (United States)

    Bratakos, M S; Kanaki, H C; Vasiliou-Waite, A; Ioannou, P V

    1990-02-01

    The nutritional selenium status of apparently healthy Greeks has been assessed by measuring fluorimetrically the selenium content of whole blood, morning urine, hair and finger nails. The means and standard deviations were 165 +/- 33, 25 +/- 7 ng Se ml-1, 416 +/- 86, and 536 +/- 91 ng Se g-1, respectively. No significant difference was found between the selenium content of whole blood, hair and finger nails, but, for morning urine, there was a significant difference between males and females. The young and the elderly have less selenium in these biological materials than other Greeks. Whole blood selenium correlates significantly with morning urine, hair, and finger nail selenium, as does hair and nail selenium of male, female and male + female Greeks. The results are compared with those in the literature and possible explanations for the observations are presented. It is concluded that the selenium status of Greeks is satisfactory.

  15. Study on selenium extraction from anode slime

    Institute of Scientific and Technical Information of China (English)

    GU; Heng

    2005-01-01

    Taking a copper anode slime as the raw material, a novel process for selenium extraction was studied. The primary selenium recovery can reach above 88.5 % and the quality index of selenium product can be up to 99.5 %. The economic benefit resulted is remarkable and environment has been protected.

  16. Trehalose amorphization and recrystallization.

    Science.gov (United States)

    Sussich, Fabiana; Cesàro, Attilio

    2008-10-13

    The stability of the amorphous trehalose prepared by using several procedures is presented and discussed. Amorphization is shown to occur by melting (T(m)=215 degrees C) or milling (room temperature) the crystalline anhydrous form TRE-beta. Fast dehydration of the di-hydrate crystalline polymorph, TRE-h, also produces an amorphous phase. Other dehydration procedures of TRE-h, such as microwave treatment, supercritical extraction or gentle heating at low scan rates, give variable fractions of the polymorph TRE-alpha, that undergo amorphization upon melting (at lower temperature, T(m)=130 degrees C). Additional procedures for amorphization, such as freeze-drying, spray-drying or evaporation of trehalose solutions, are discussed. All these procedures are classified depending on the capability of the undercooled liquid phase to undergo cold crystallization upon heating the glassy state at temperatures above the glass transition temperature (T(g)=120 degrees C). The recrystallizable amorphous phase is invariably obtained by the melt of the polymorph TRE-alpha, while other procedures always give an amorphous phase that is unable to crystallize above T(g). The existence of two different categories is analyzed in terms of the transformation paths and the hypothesis that the systems may exhibit different molecular mobilities.

  17. Selenium and inflammatory bowel disease.

    Science.gov (United States)

    Kudva, Avinash K; Shay, Ashley E; Prabhu, K Sandeep

    2015-07-15

    Dietary intake of the micronutrient selenium is essential for normal immune functions. Selenium is cotranslationally incorporated as the 21st amino acid, selenocysteine, into selenoproteins that function to modulate pathways involved in inflammation. Epidemiological studies have suggested an inverse association between selenium levels and inflammatory bowel disease (IBD), which includes Crohn's disease and ulcerative colitis that can potentially progress to colon cancer. However, the underlying mechanisms are not well understood. Here we summarize the current literature on the pathophysiology of IBD, which is multifactorial in origin with unknown etiology. We have focused on a few selenoproteins that mediate gastrointestinal inflammation and activate the host immune response, wherein macrophages play a pivotal role. Changes in cellular oxidative state coupled with altered expression of selenoproteins in macrophages drive the switch from a proinflammatory phenotype to an anti-inflammatory phenotype to efficiently resolve inflammation in the gut and restore epithelial barrier integrity. Such a phenotypic plasticity is accompanied by changes in cytokines, chemokines, and bioactive metabolites, including eicosanoids that not only mitigate inflammation but also partake in restoring gut homeostasis through diverse pathways involving differential regulation of transcription factors such as nuclear factor-κB and peroxisome proliferator-activated receptor-γ. The role of the intestinal microbiome in modulating inflammation and aiding in selenium-dependent resolution of gut injury is highlighted to provide novel insights into the beneficial effects of selenium in IBD.

  18. Amorphous iron (II) carbonate

    DEFF Research Database (Denmark)

    Sel, Ozlem; Radha, A.V.; Dideriksen, Knud;

    2012-01-01

    exothermic than that of amorphous calcium carbonate (ACC). This suggests that enthalpy of crystallization in carbonate systems is ionic-size controlled, which may have significant implications in a wide variety of conditions, including geological sequestration of anthropogenic carbon dioxide.......Abstract The synthesis, characterization and crystallization energetics of amorphous iron (II) carbonate (AFC) are reported. AFC may form as a precursor for siderite (FeCO3). The enthalpy of crystallization (DHcrys) of AFC is similar to that of amorphous magnesium carbonate (AMC) and more...

  19. Colloidally stable selenium@copper selenide core@shell nanoparticles as selenium source for manufacturing of copper-indium-selenide solar cells.

    Science.gov (United States)

    Dong, Hailong; Quintilla, Aina; Cemernjak, Marco; Popescu, Radian; Gerthsen, Dagmar; Ahlswede, Erik; Feldmann, Claus

    2014-02-01

    Selenium nanoparticles with diameters of 100-400nm are prepared via hydrazine-driven reduction of selenious acid. The as-prepared amorphous, red selenium (a-Se) particles were neither a stable phase nor were they colloidally stable. Due to phase transition to crystalline (trigonal), grey selenium (t-Se) at or even below room temperature, the particles merged rapidly and recrystallized as micronsized crystal needles. As a consequence, such Se particles were not suited for layer deposition and as a precursor to manufacture thin-film CIS (copper indium selenide/CuInSe2) solar cells. To overcome this restriction, Se@CuSe core@shell particles are presented here. For these Se@CuSe core@shell nanoparticles, the phase transition a-Se→t-Se is shifted to temperatures higher than 100°C. Moreover, a spherical shape of the particles is retained even after phase transition. Composition and structure of the Se@CuSe core@shell nanostructure are evidenced by electron microscopy (SEM/STEM), DLS, XRD, FT-IR and line-scan EDXS. As a conceptual study, the newly formed Se@CuSe core@shell nanostructures with CuSe acting as a protecting layer to increase the phase-transition temperature and to improve the colloidal stability were used as a selenium precursor for manufacturing of thin-film CIS solar cells and already lead to conversion efficiencies up to 3%.

  20. Selenium uptake by edible oyster mushrooms (Pleurotus sp.) from selenium-hyperaccumulated wheat straw.

    Science.gov (United States)

    Bhatia, Poonam; Prakash, Ranjana; Prakash, N Tejo

    2013-01-01

    In an effort to produce selenium (Se)-fortifying edible mushrooms, five species of oyster mushroom (Pleurotus sp.), were cultivated on Se-rich wheat straw collected from a seleniferous belt of Punjab, India. Total selenium was analyzed in the selenium hyperaccumulated wheat straw and the fruiting bodies. Significantly high levels (pmushrooms grown on Se-rich wheat straw. To the best of our knowledge, accumulation and quantification of selenium in mushrooms has hitherto not been reported with substrates naturally enriched with selenium. The results demonstrate the potential of selenium-rich agricultural residues as substrates for production of Se-enriched mushrooms and the ability of different species of oyster mushrooms to absorb and fortify selenium. The study envisages potential use of selenium-rich agricultural residues towards cultivation of Se-enriched mushrooms for application in selenium supplementation or neutraceutical preparations.

  1. Amorphous Solid Water:

    DEFF Research Database (Denmark)

    Wenzel, Jack; Linderstrøm-Lang, C. U.; Rice, Stuart A.

    1975-01-01

    The structure factor of amorphous solid D2O deposited from the vapor at 10°K has been obtained by measuring the neutron diffraction spectrum in the wave vector transfer from 0.8 to 12.3 reciprocal angstroms. The results indicate that the phase investigated is amorphous and has a liquiid-like stru......The structure factor of amorphous solid D2O deposited from the vapor at 10°K has been obtained by measuring the neutron diffraction spectrum in the wave vector transfer from 0.8 to 12.3 reciprocal angstroms. The results indicate that the phase investigated is amorphous and has a liquiid...

  2. Amorphous pharmaceutical solids.

    Science.gov (United States)

    Vranić, Edina

    2004-07-01

    Amorphous forms are, by definition, non-crystalline materials which possess no long-range order. Their structure can be thought of as being similar to that of a frozen liquid with the thermal fluctuations present in a liquid frozen out, leaving only "static" structural disorder. The amorphous solids have always been an essential part of pharmaceutical research, but the current interest has been raised by two developments: a growing attention to pharmaceutical solids in general, especially polymorphs and solvates and a revived interest in the science of glasses and the glass transition. Amorphous substances may be formed both intentionally and unintentionally during normal pharmaceutical manufacturing operations. The properties of amorphous materials can be exploited to improve the performance of pharmaceutical dosage forms, but these properties can also give rise to unwanted effects that need to be understood and managed in order for the systems to perform as required.

  3. Selenium Content in Seafood in Japan

    Directory of Open Access Journals (Sweden)

    Haruka Iida

    2013-01-01

    Full Text Available Selenium is an essential micronutrient for humans, and seafood is one of the major selenium sources, as well as red meat, grains, eggs, chicken, liver and garlic. A substantial proportion of the total amount of selenium is present as selenium containing imidazole compound, selenoneine, in the muscles of ocean fish. In order to characterize the selenium content in seafood, the total selenium levels were measured in the edible portions of commercially important fish and shellfish species. Among the tested edible portions, alfonsino muscle had the highest selenium levels (concentration of 1.27 mg/kg tissue. High levels of selenium (1.20–1.07 mg/kg were also found in the salted ovary products of mullet and Pacific herring. In other fish muscles, the selenium levels ranged between 0.12 and 0.77 mg/kg tissue. The selenium levels were closely correlated with the mercury levels in the white and red muscles in alfonsino. The selenium content in spleen, blood, hepatopancreas, heart, red muscle, white muscle, brain, ovary and testis ranged between 1.10 and 24.8 mg/kg tissue in alfonsino.

  4. Selenium speciation in ground water

    Energy Technology Data Exchange (ETDEWEB)

    Atalay, A.

    1990-07-10

    Selenium toxicity diseases in animals may occur when the intake exceeds 4 mg/kg and selenium deficiency symptoms may occur when dietary intake is less than 0.04 mg/kg. Since the selenium dietary requirement is very close to toxic concentration, it is important to understand the distribution of selenium in the environment. Selenium occurs in four oxidation states (-II, 0, +IV, and +VI) as selenide, elemental selenium, selenite and selenate. Selenate is reported as more soluble and less adsorbed than selenite. Selenate is more easily leached from soils and is the most available form for plants. Increased mobility of Se into the environment via anthropogenic activities, and the potential oxidation-reduction behavior of the element have made it imperative to study the aquatic chemistry of Se. For this purpose, Se species are divided into two different categories: dissolved Se (in material that passes through filters with 0.45 u openings) and particulate Se (in material of particle size > 0.45 mm) typically suspended sediment and other suspended solids. Element and colloidal phase, not truly dissolved, but passing through the filter is deemed to consist of selenium (-2,0). In dissolved state selenium may exist in three of its four oxidation states; Se(-II), Se(+IV), and Se(+VI). Particulate Se may exist in the same oxidation states as dissolved Se and can be found in different phases of the particulate matter. In sediments, Se may be within the organic material, iron and manganese oxides, carbonates or other mineral phases. The actual chemical forms of Se may be adsorbed to or coprecipitated with these phases (primarily selenite, SeO{sub 3}{sup 2{minus}}) and selenate, SeO{sub 4}{sup 2{minus}}. Selenide, Se(-II), can be covalently bound in the organic portion of a sediment. In addition, Se may be found in anoxic sediments as insoluble metal selenide precipitates, an insoluble elemental Se or as ferroselite (FeSe{sub 2}) and Se containing pyrite.

  5. Dissimilatory Reduction of Elemental Selenium to Selenide in Sediments and Anaerobic Cultures of Selenium Respiring Bacteria

    Science.gov (United States)

    Herbel, M. J.; Switzer-Blum, J.; Oremland, R. S.

    2001-12-01

    Selenium contaminated environments often contain elemental Se (Se0) in their sediments that originates from dissimilatory reduction of Se oxyanions. The forms of Se in sedimentary rocks similarly contain high proportions of Se0, but much of the Se is also in the form of metal selenides, Se-2. It is not clear if the occurrence of these selenides is due to microbial reduction of Se0, or some other biological or chemical process. In this investigation we examined the possibility that bacterial respiratory reduction of Se0 to Se-2 could explain the presence of the latter species in sedimentary rocks. We conducted incubations of anoxic sediment slurries amended with different forms of Se0. High levels of Se0 (mM) were added to San Francisco Bay sediments in order to enhance the detection of soluble HSe-, which was precipitated with Cu2+ then redissolved and quantified by ICP-MS. Concentrations of HSe- were highest in live samples amended with red amorphous Se0 formed by either microbial reduction of Se+4 ("biogenic Se0") or by chemical oxidation of H2Se(g) ("chem. Se0"); very little HSe- was formed in those amended with black crystalline Se0, indicating the general lack of reactivity of this allotrope. Controls poisoned with 10% formalin did not produce HSe- from additions of chem. Se0. Reduction of both forms of red amorphous Se0 to HSe- occurred vigorously in growing cultures of Bacillus selenitireducens, an anaerobic halophile previously isolated from sediments of Mono Lake, CA. Up to 73% and 68% of red amorphous, biogenic Se0 or chem. Se0, respectively, was reduced to HSe- during growth of B. selenitireducens, (incubation time ~ 200 hrs): oxidation of lactate to acetate as well as cell density increases indicated that a dissimilatory reduction pathway was likely. Reduction was most enhanced when cells were previously grown on elemental sulfur or Se+4. In contrast to the growth experiments, washed cell suspensions of B. selenitireducens exhibited no HSe- production

  6. Biomarkers of Selenium Status

    Directory of Open Access Journals (Sweden)

    Gerald F. Combs, Jr.

    2015-03-01

    Full Text Available The essential trace element, selenium (Se, has multiple biological activities, which depend on the level of Se intake. Relatively low Se intakes determine the expression of selenoenzymes in which it serves as an essential constituent. Higher intakes have been shown to have anti-tumorigenic potential; and very high Se intakes can produce adverse effects. This hierarchy of biological activities calls for biomarkers informative at different levels of Se exposure. Some Se-biomarkers, such as the selenoproteins and particularly GPX3 and SEPP1, provide information about function directly and are of value in identifying nutritional Se deficiency and tracking responses of deficient individuals to Se-treatment. They are useful under conditions of Se intake within the range of regulated selenoprotein expression, e.g., for humans <55 μg/day and for animals <20 μg/kg diet. Other Se-biomarkers provide information indirectly through inferences based on Se levels of foods, tissues, urine or feces. They can indicate the likelihood of deficiency or adverse effects, but they do not provide direct evidence of either condition. Their value is in providing information about Se status over a wide range of Se intake, particularly from food forms. There is need for additional Se biomarkers particularly for assessing Se status in non-deficient individuals for whom the prospects of cancer risk reduction and adverse effects risk are the primary health considerations. This would include determining whether supranutritional intakes of Se may be required for maximal selenoprotein expression in immune surveillance cells. It would also include developing methods to determine low molecular weight Se-metabolites, i.e., selenoamino acids and methylated Se-metabolites, which to date have not been detectable in biological specimens. Recent analytical advances using tandem liquid chromatography-mass spectrometry suggest prospects for detecting these metabolites.

  7. Selenium and endocrine systems.

    Science.gov (United States)

    Beckett, Geoffrey J; Arthur, John R

    2005-03-01

    The trace element selenium (Se) is capable of exerting multiple actions on endocrine systems by modifying the expression of at least 30 selenoproteins, many of which have clearly defined functions. Well-characterized selenoenzymes are the families of glutathione peroxidases (GPXs), thioredoxin reductases (TRs) and iodothyronine deiodinases (Ds). These selenoenzymes are capable of modifying cell function by acting as antioxidants and modifying redox status and thyroid hormone metabolism. Se is also involved in cell growth, apoptosis and modifying the action of cell signalling systems and transcription factors. During thyroid hormone synthesis GPX1, GPX3 and TR1 are up-regulated, providing the thyrocytes with considerable protection from peroxidative damage. Thyroidal D1 in rats and both D1 and D2 in humans are also up-regulated to increase the production of bioactive 3,5,3'-tri-iodothyronine (T3). In the basal state, GPX3 is secreted into the follicular lumen where it may down-regulate thyroid hormone synthesis by decreasing hydrogen peroxide concentrations. The deiodinases are present in most tissues and provide a mechanism whereby individual tissues may control their exposure to T3. Se is also able to modify the immune response in patients with autoimmune thyroiditis. Low sperm production and poor sperm quality are consistent features of Se-deficient animals. The pivotal link between Se, sperm quality and male fertility is GPX4 since the enzyme is essential to allow the production of the correct architecture of the midpiece of spermatozoa. Se also has insulin-mimetic properties, an effect that is probably brought about by stimulating the tyrosine kinases involved in the insulin signalling cascade. Furthermore, in the diabetic rat, Se not only restores glycaemic control but it also prevents or alleviates the adverse effects that diabetes has on cardiac, renal and platelet function.

  8. Present status of amorphous In–Ga–Zn–O thin-film transistors

    Directory of Open Access Journals (Sweden)

    Toshio Kamiya, Kenji Nomura and Hideo Hosono

    2010-01-01

    Full Text Available The present status and recent research results on amorphous oxide semiconductors (AOSs and their thin-film transistors (TFTs are reviewed. AOSs represented by amorphous In–Ga–Zn–O (a-IGZO are expected to be the channel material of TFTs in next-generation flat-panel displays because a-IGZO TFTs satisfy almost all the requirements for organic light-emitting-diode displays, large and fast liquid crystal and three-dimensional (3D displays, which cannot be satisfied using conventional silicon and organic TFTs. The major insights of this review are summarized as follows. (i Most device issues, such as uniformity, long-term stability against bias stress and TFT performance, are solved for a-IGZO TFTs. (ii A sixth-generation (6G process is demonstrated for 32'' and 37'' displays. (iii An 8G sputtering apparatus and a sputtering target have been developed. (iv The important effect of deep subgap states on illumination instability is revealed. (v Illumination instability under negative bias has been intensively studied, and some mechanisms are proposed. (vi Degradation mechanisms are classified into back-channel effects, the creation of traps at an interface and in the gate insulator, and the creation of donor states in annealed a-IGZO TFTs by the Joule heating; the creation of bulk defects should also be considered in the case of unannealed a-IGZO TFTs. (vii Dense passivation layers improve the stability and photoresponse and are necessary for practical applications. (viii Sufficient knowledge of electronic structures and electron transport in a-IGZO has been accumulated to construct device simulation models.

  9. Chemical Form of Selenium in Naturally Selenium-Rich Lentils (Lens Culinaris L.) From Saskatchewan

    Energy Technology Data Exchange (ETDEWEB)

    Thavarajah, D.; Vandenberg, A.; George, G.N.; Pickering, I.J.

    2009-06-04

    Lentils (Lens culinaris L.) are a source of many essential dietary components and trace elements for human health. In this study we show that lentils grown in the Canadian prairies are additionally enriched in selenium, an essential micronutrient needed for general well-being, including a healthy immune system and protection against cancer. Selenium K near-edge X-ray absorption spectroscopy (XAS) has been used to examine the selenium biochemistry of two lentil cultivars grown in various locations in Saskatchewan, Canada. We observe significant variations in total selenium concentration with geographic location and cultivar; however, almost all the selenium (86--95%) in these field-grown lentils is present as organic selenium modeled as selenomethionine with a small component (5--14%) as selenate. As the toxicities of certain forms of arsenic and selenium are antagonistic, selenium-rich lentils may have a pivotal role to play in alleviating the chronic arsenic poisoning in Bangladesh.

  10. Usefulness of DICOM headers in the analysis of two biplane X-ray systems setting (image intensifier and flat panel) used in pediatric interventional cardiology in Chile;Utilidad de las cabeceras DICOM en el analisis de la configuracion de dos sistemas de rayos X biplano (intensificador de imagen y panel plano) utilizados en cardiologia intervencionista pediatrica en Chile

    Energy Technology Data Exchange (ETDEWEB)

    Ubeda, C.; Vergara, F. [Universidad de Tarapaca, Arica (Chile). Dept. de Ciencias Clinicas; Vano, E. [Universidad Complutense, Madrid, (Spain). Hospital Clinico San Carlos. Dept. de Radiologia; Miranda, P. [Hospital Luis Calvo Mackenna, Santiago (Chile). Dept. de Hemodinamia; Valenzuela, E. [Universidad Catolica de Chile, Santiago (Chile). Hospital Clinico. Servicio de Hemodinamia; Leyton, F. [Instituto de Salud Publica de Chile, Santiago (Chile)

    2009-07-01

    The setting of two biplane X ray systems were evaluated (image intensifier (II) and flat panel (PP)), through DICOM tags from 32 images created during the characterization of both systems. The technical parameters adjusted for systems were: 63,8 to 80,0 kV and 15,0 to 388,0 mA, for the system with II and 52,0 to 77,0 kV and 25,0 to 476,0 mA, for the system with PP detector. Both equipment presented a different mA adjustment, when moving from fluoroscopy modes low dose (FL), medium dose (FM) and high dose (FH) to cine mode (CI). Two dosimetric quantities were evaluated, the first one was the dose-area product (DAP) which gave as a result for FB mode, between 0,03 to 0,35 uGycm{sup 2}/image (II) and from 0,05 a 0,69 uGycm{sup 2}/image (PP), when the polymethyl methacrylate (PMMA) thickness was incremented from 4 to 16 cm. In cine mode the DAP quantity showed, percentage values from 24 to -1 % for the same PMMA increment. Skin cumulative dose was the second quantity evaluated and showed an increment of incident air kerma (KAI)/image in factors from 17 to 35 (II) and 15 to 28 (PP) when used in CI mode instead of FB mode, to the different PMMA thicknesses used. This dose increment for CI mode must be considered by cardiologists, to use the fluoroscopic run as an alternative to document part of the procedures when there is no need to use a high quality image (author)

  11. Baseline selenium status and effects of selenium and vitamin E supplementation on prostate cancer risk

    OpenAIRE

    Kristal, AR; Darke, AK; Morris, JS; Tangen, CM; Goodman, PJ; Thompson, IM; Meyskens, FL; Goodman, GE; Minasian, LM; Parnes, HL; Lippman, SM; Klein, EA

    2014-01-01

    Background The Selenium and Vitamin E Cancer Prevention Trial found no effect of selenium supplementation on prostate cancer (PCa) risk but a 17% increased risk from vitamin E supplementation. This case-cohort study investigates effects of selenium and vitamin E supplementation conditional upon baseline selenium status. Methods There were 1739 total and 489 high-grade (Gleason 7-10) PCa cases and 3117 men in the randomly selected cohort. Proportional hazards models estimated hazard ratios (HR...

  12. Image quality of a digital chest radiography system based on a selenium detector.

    Science.gov (United States)

    Neitzel, U; Maack, I; Günther-Kohfahl, S

    1994-04-01

    A digital chest radiography system has been developed, with a detector based on the photoelectric properties of amorphous selenium. The selenium layer is deposited on a cylindrical aluminium drum, large enough to cover the full field of view for chest imaging. The electrostatic charge image which is formed on the selenium surface after x-ray exposure is read out by electrometer probes using fast drum rotation. For a physical evaluation of the attainable image quality, the characteristic curve, the modulation transfer function, and the noise spectra were measured. From these measurements, the signal-to-noise properties of the detector in terms of detective quantum efficiency (DQE) and noise equivalent quanta (NEQ) were derived. The results show that the selenium-based detector has a wide dynamic range and a significantly better DQE than screen-film and storage phosphor systems for spatial frequencies below the Nyquist limit (2.7 lp/mm). As a consequence, the detectability of small, low-contrast details is considerably improved.

  13. Does selenium supplementation affect thyroid function?

    DEFF Research Database (Denmark)

    Winther, Kristian Hillert; Bonnema, Steen Joop; Cold, Frederik

    2015-01-01

    OBJECTIVE: Selenium is present in the active site of proteins important for thyroid hormone synthesis and metabolism. The objective of this study is to investigate the effect of selenium supplementation in different doses on thyroid function, under conditions of suboptimal dietary selenium intake....... DESIGN: The Danish PREvention of Cancer by Intervention with SElenium pilot study (DK-PRECISE) is a randomized, double-blinded, placebo-controlled trial. A total of 491 males and females aged 60-74 years were randomized to 100 μg (n=124), 200 μg (n=122), or 300 μg (n=119) selenium-enriched yeast......=0.015), respectively, per 100 μg/day increase, with insignificant differences between 6 months and 5 years. No significant effects were found for FT3 and FT3:FT4 ratio. CONCLUSIONS: In euthyroid subjects, selenium supplementation minutely and dose-dependently affects thyroid function, when compared...

  14. Tests of Flat Panels with Four Types of Stiffeners

    Science.gov (United States)

    1943-01-01

    within one-half of 1 percent by a standard tensile test. in this test two Huggenberger tensometers with 1-inch gage lengths were used to measure the...into three equal parts by a lever arrsngement, the loads being 25-pound bags of shot. This lever system wss designed to fit all four stiffener spacings...the platens about an axis normal to the plane of the specimen was very small. In the second and third groups of tests, tensometers were also attached

  15. High-bandwidth remote flat panel display interconnect system

    Science.gov (United States)

    Peterson, Darrel G.

    1999-08-01

    High performance electronic displays (CRT, AMLCD, TFEL, plasma, etc.) require wide bandwidth electrical drive signals to produce the desired display images. When the image generation and/or image processing circuitry is located within the same line replaceable unit (LRU) as the display media, the transmission of the display drive signals to the display media presents no unusual design problems. However, many aircraft cockpits are severely constrained for available space behind the instrument panel. This often forces the system designer to specify that only the display media and its immediate support circuitry are to be mounted in the instrument panel. A wide bandwidth interconnect system is then required to transfer image data from the display generation circuitry to the display unit. Image data transfer rates of nearly 1.5 Gbits/second may be required when displaying full motion video at a 60 Hz field rate. In addition to wide bandwidth, this interconnect system must exhibit several additional key characteristics: (1) Lossless transmission of image data; (2) High reliability and high integrity; (3) Ease of installation and field maintenance; (4) High immunity to HIRF and electrical noise; (5) Low EMI emissions; (6) Long term supportability; and (7) Low acquisition and maintenance cost. Rockwell Collins has developed an avionics grade remote display interconnect system based on the American National Standards Institute Fibre Channel standard which meets these requirements. Readily available low cost commercial off the shelf (COTS) components are utilized, and qualification tests have confirmed system performance.

  16. Beam-Steerable Flat-Panel Reflector Antenna

    Science.gov (United States)

    Lee, Choon Sae; Lee, Chanam; Miranda, Felix A.

    2005-01-01

    Many space applications require a high-gain antenna that can be easily deployable in space. Currently, the most common high-gain antenna for space-born applications is an umbrella-type reflector antenna that can be folded while being lifted to the Earth orbit. There have been a number of issues to be resolved for this type of antenna. The reflecting surface of a fine wire mesh has to be light in weight and flexible while opening up once in orbit. Also the mesh must be a good conductor at the operating frequency. In this paper, we propose a different type of high-gain antenna for easy space deployment. The proposed antenna is similar to reflector antennas except the curved main reflector is replaced by a flat reconfigurable surface for easy packing and deployment in space. Moreover it is possible to steer the beam without moving the entire antenna system.

  17. Human Visual Performance and Flat Panel Display Image Quality

    Science.gov (United States)

    1980-07-01

    In0.42Ga0.58 amber 617 SiC yellow 590 GaN blue 440 GaN green 515 GaAs:Si with green 550 YF3YbEr GaAs:Si with blue 470 YF3:Yb:Tn InSe yellow 590 3.0...nm, from a neon gas. Other gases , and their discharge colors, which have been used in gas dis- charge displays incude argon (blue), cadmium (red

  18. Selenium and magnesium status in fibromyalgia.

    Science.gov (United States)

    Eisinger, J; Plantamura, A; Marie, P A; Ayavou, T

    1994-12-01

    Muscle pain has been associated with magnesium (Mg) and selenium (Se) deficiency: magnesium and selenium status were investigated in fibromyalgia (FM). Erythrocyte (E), leucocyte (L) and serum (S) magnesium, serum selenium and zinc, and vitamin B1, B2, A or E status were assessed in 22 patients with fibromyalgia and in 23 age-matched healthy controls. LMg is significantly increased (P fibromyalgia. These magnesium abnormalities are associated with previously-reported impairment of thiamin metabolism. Antioxidant status (as well as plasma malondialdehyde) is unchanged in fibromyalgia and serum selenium levels, slightly but not significantly correlated with serum magnesium, is normal.

  19. Selenium status of idiopathic infertile Nigerian males.

    Science.gov (United States)

    Akinloye, Oluyemi; Arowojolu, A O; Shittu, O B; Adejuwon, C A; Osotimehin, Babatunde

    2005-04-01

    Selenium concentration in the sera and seminal plasma of 60 infertile males (40 oligospermia and 20 azoospermia) and 40 males with proven evidence of fertility (normospermia; control group) were estimated using atomic absorption spectrophotometry. Results were correlated with spermatogram and hormonal levels in order to determine their relationship and significance in male infertility. The mean serum concentrations of selenium was found to be significantly increased in oligospermic compared to azoospermic subjects and controls (p selenium to seminal plasma selenium was 1: 1 in controls, 4: 1 in oligospermia, and 1: 2 in azoospermic subject.A significant inverse correlation was observed between serum selenium level and sperm count (p selenium correlated with spermatozoa motility, viability, and morphology. Serum selenium level shows positive correlation with the serum testosterone level (p selenium in serum and seminal plasma compartment of control males. A disturbance in this balance has a significant influence on spermatogenesis. Selenium appears to have a positive influence on Leydig cells, thus influencing the secretion of testosterone.

  20. How to use the world's scarce selenium resources efficiently to increase the selenium concentration in food.

    Science.gov (United States)

    Haug, Anna; Graham, Robin D; Christophersen, Olav A; Lyons, Graham H

    2007-12-01

    The world's rare selenium resources need to be managed carefully. Selenium is extracted as a by-product of copper mining and there are no deposits that can be mined for selenium alone. Selenium has unique properties as a semi-conductor, making it of special value to industry, but it is also an essential nutrient for humans and animals and may promote plant growth and quality. Selenium deficiency is regarded as a major health problem for 0.5 to 1 billion people worldwide, while an even larger number may consume less selenium than required for optimal protection against cancer, cardiovascular diseases and severe infectious diseases including HIV disease. Efficient recycling of selenium is difficult. Selenium is added in some commercial fertilizers, but only a small proportion is taken up by plants and much of the remainder is lost for future utilization. Large biofortification programmes with selenium added to commercial fertilizers may therefore be a fortification method that is too wasteful to be applied to large areas of our planet. Direct addition of selenium compounds to food (process fortification) can be undertaken by the food industry. If selenomethionine is added directly to food, however, oxidation due to heat processing needs to be avoided. New ways to biofortify food products are needed, and it is generally observed that there is less wastage if selenium is added late in the production chain rather than early. On these bases we have proposed adding selenium-enriched, sprouted cereal grain during food processing as an efficient way to introduce this nutrient into deficient diets. Selenium is a non-renewable resource. There is now an enormous wastage of selenium associated with large-scale mining and industrial processing. We recommend that this must be changed and that much of the selenium that is extracted should be stockpiled for use as a nutrient by future generations.

  1. Review on Nano SeleniumProduced by Bacteria

    Directory of Open Access Journals (Sweden)

    LI Ji-xiang

    2014-12-01

    Full Text Available Selenium (Se is a kind of essential trace element for people and animal, while ionic state of selenium is toxic with high concentrations and will cause the selenium pollution. Nano-selenium is stable, nontoxic with higher biological activity. Application of bacteria reducing selenite or selenate to biological nano-selenium has great potential in selenium pollution control and nano-selenium production. This review summarizes the research progress of the red elemental nano-selenium reduced by bacteria including characteristics and application of nano-selenium, effects of carbon and nitrogen source, oxygen, temperature and pH in bacteria nano-selenium production, and molecular mechanisms of nano-selenium reduced by bacteria.

  2. Self-aligned top-gate amorphous indium zinc oxide thin-film transistors exceeding low-temperature poly-Si transistor performance.

    Science.gov (United States)

    Park, Jae Chul; Lee, Ho-Nyeon; Im, Seongil

    2013-08-14

    Thin-film transistor (TFT) is a key component of active-matrix flat-panel displays (AMFPDs). These days, the low-temperature poly silicon (LTPS) TFTs are to match with advanced AMFPDs such as the active matrix organic light-emitting diode (AMOLED) display, because of their high mobility for fast pixel switching. However, the manufacturing process of LTPS TFT is quite complicated, costly, and scale-limited. Amorphous oxide semiconductor (AOS) TFT technology is another candidate, which is as simple as that of conventioanl amorphous (a)-Si TFTs in fabrication but provides much superior device performances to those of a-Si TFTs. Hence, various AOSs have been compared with LTPS for active channel layer of the advanced TFTs, but have always been found to be relatively inferior to LTPS. In the present work, we clear the persistent inferiority, innovating the device performaces of a-IZO TFT by adopting a self-aligned coplanar top-gate structure and modifying the surface of a-IZO material. Herein, we demonstrate a high-performance simple-processed a-IZO TFT with mobility of ∼157 cm(2) V(-1) s(-1), SS of ∼190 mV dec(-1), and good bias/photostabilities, which overall surpass the performances of high-cost LTPS TFTs.

  3. Review of selenium thermodynamic data

    Science.gov (United States)

    Cowan, C. E.

    1988-02-01

    This report assesses the accuracy and completeness of available thermodynamic data on selenium. A review of experimental methods from published literature on selenium thermodynamic data focused on chemical reactions responsible for the formation of both aqueous complexes and solid phases of selenate, selenite, and selenide. The reviewer selected best data values, based on the methods used for estimating thermodynamic data. After inclusion of these values into the MINTEQ model, a validation study evaluated model performance for selenite and selenide solid phases. Lack of selenate data precluded model validation for this compound. The review furnished data on 22 aqueous complexes of selenite, 15 of selenide, and 17 of selenate, as well as 21 solid phases of selenite, 20 of selenide and 8 of selenate. These data proved inadequate to represent the formation of species in the solid phase. The validation study gave inconclusive predictions of selenite and selenide solubility and could not be used to assess the accuracy or completeness of the thermodynamic data.

  4. Comparison of Indirect CsI/a:Si and Direct a:Se Digital Radiography. An assessment of contrast and detail visualization

    Energy Technology Data Exchange (ETDEWEB)

    Fischbach, F.; Freund, T.; Pech, M.; Werk, M.; Bassir, C.; Stoever, B.; Felix, R.; Ricke, J. [Humboldt-Univ. Medical School, Campus Virchow-Klinikum, Berlin (Germany). Dept. of Radiology

    2003-11-01

    Purpose: To assess and quantify the image quality at two dose levels for an amorphous Silicon (a:Si) Cesium Iodide (CsI) flat panel system compared with a direct amorphous Selenium (a:Se) digital radiography system. Material and Methods: A contrast detectability test was performed employing the CDRAD-phantom at mAs-values leading to approximately equal phantom entrance doses of 41.4, 57.9, 75.1 and 120.8 {mu}Gy for the a:Se and 39.9, 58.4, 75.6 and 117.9 {mu}Gy for the CsI system. Images were presented to 4 independent observers. For quantitative comparison, the image quality figure (IQF) was calculated. Statistical analysis was performed using Pearson's correlation and the Wilcoxon test. A ROC-analysis was performed employing the TRG-phantom in a high- and a low-dose setting leading to entrance doses of 126.2 and 35 {mu}Gy for the direct, and 125.9 and 34.4 {mu}Gy for the indirect system. Statistical significance was evaluated using the Wilcoxon test. Results: The flat panel a:Si digital system provided superior results compared with the a:Se drum digital system with respect to low-dose settings for CDRAD-phantom and ROC-analysis, ensuring a better image quality with respect to contrast and detail detectability. Higher-dose settings provided similar results for both systems. Conclusion: Image quality of a:Si flat panel digital radiography proved to be superior to a:Se drum digital radiography using low-dose settings. If the primary target is dose reduction indirect flat panel technology should be used. Digital radiography amorphous selenium amorphous silicon chest radiography.

  5. Selenium and prostate cancer prevention: insights from the selenium and vitamin E cancer prevention trial (SELECT).

    Science.gov (United States)

    Nicastro, Holly L; Dunn, Barbara K

    2013-04-03

    The Selenium and Vitamin E Cancer Prevention Trial (SELECT) was conducted to assess the efficacy of selenium and vitamin E alone, and in combination, on the incidence of prostate cancer. This randomized, double-blind, placebo-controlled, 2 × 2 factorial design clinical trial found that neither selenium nor vitamin E reduced the incidence of prostate cancer after seven years and that vitamin E was associated with a 17% increased risk of prostate cancer compared to placebo. The null result was surprising given the strong preclinical and clinical evidence suggesting chemopreventive activity of selenium. Potential explanations for the null findings include the agent formulation and dose, the characteristics of the cohort, and the study design. It is likely that only specific subpopulations may benefit from selenium supplementation; therefore, future studies should consider the baseline selenium status of the participants, age of the cohort, and genotype of specific selenoproteins, among other characteristics, in order to determine the activity of selenium in cancer prevention.

  6. Preparation of selenium yeasts I. Preparation of selenium-enriched Saccharomyces cerevisiae.

    Science.gov (United States)

    Suhajda, A; Hegóczki, J; Janzsó, B; Pais, I; Vereczkey, G

    2000-04-01

    Selenium (Se) is an essential micronutrient for human and animal organisms. Organic selenium complexes and selenium-containing amino acids are considered the most bioavailable. Under appropriate conditions yeasts are capable of accumulating large amounts of trace elements, such as selenium, and incorporating them into organic compounds. It has been found that introduction of water-soluble selenium salt as a component of the culture medium for yeasts produced by conventional batch processing results in a substantial amount of selenium being absorbed by the yeast. Using a culture medium supplemented with 30 microg/mL sodium-selenite added during the exponential growth phase results in selenium-accumulation in the range of 1200-1400 microg/g dried baker's yeast (Saccharomyces cerevisiae) measured by ICP-AES method. In our previous studies it was shown that higher amounts of sodium-selenite in the culture medium have a strong inhibitory effect on the growth of this yeast. As a consequence of variations in cultivation conditions we obtained selenium yeast with different inorganic selenium content. The most important parameters influencing incorporated forms of selenium are pH value and dissolved oxygen level in the culture medium, and depending on these the selenium consumption rate of the yeast. A 0.40-0.50 mg/g h-1 specific selenium consumption rate was found to be appropriate to obtain selenium-enriched bakers' yeast of a high quality. Under suitable conditions the undesirable inorganic selenium content of the yeast could be suppressed to as low as 5-6% at the expense, however, of approximately a 20% decrease in the final biomass.

  7. Substrate and Passivation Techniques for Flexible Amorphous Silicon-Based X-ray Detectors

    Science.gov (United States)

    Marrs, Michael A.; Raupp, Gregory B.

    2016-01-01

    Flexible active matrix display technology has been adapted to create new flexible photo-sensing electronic devices, including flexible X-ray detectors. Monolithic integration of amorphous silicon (a-Si) PIN photodiodes on a flexible substrate poses significant challenges associated with the intrinsic film stress of amorphous silicon. This paper examines how altering device structuring and diode passivation layers can greatly improve the electrical performance and the mechanical reliability of the device, thereby eliminating one of the major weaknesses of a-Si PIN diodes in comparison to alternative photodetector technology, such as organic bulk heterojunction photodiodes and amorphous selenium. A dark current of 0.5 pA/mm2 and photodiode quantum efficiency of 74% are possible with a pixelated diode structure with a silicon nitride/SU-8 bilayer passivation structure on a 20 µm-thick polyimide substrate. PMID:27472329

  8. Substrate and Passivation Techniques for Flexible Amorphous Silicon-Based X-ray Detectors

    Directory of Open Access Journals (Sweden)

    Michael A. Marrs

    2016-07-01

    Full Text Available Flexible active matrix display technology has been adapted to create new flexible photo-sensing electronic devices, including flexible X-ray detectors. Monolithic integration of amorphous silicon (a-Si PIN photodiodes on a flexible substrate poses significant challenges associated with the intrinsic film stress of amorphous silicon. This paper examines how altering device structuring and diode passivation layers can greatly improve the electrical performance and the mechanical reliability of the device, thereby eliminating one of the major weaknesses of a-Si PIN diodes in comparison to alternative photodetector technology, such as organic bulk heterojunction photodiodes and amorphous selenium. A dark current of 0.5 pA/mm2 and photodiode quantum efficiency of 74% are possible with a pixelated diode structure with a silicon nitride/SU-8 bilayer passivation structure on a 20 µm-thick polyimide substrate.

  9. Substrate and Passivation Techniques for Flexible Amorphous Silicon-Based X-ray Detectors.

    Science.gov (United States)

    Marrs, Michael A; Raupp, Gregory B

    2016-07-26

    Flexible active matrix display technology has been adapted to create new flexible photo-sensing electronic devices, including flexible X-ray detectors. Monolithic integration of amorphous silicon (a-Si) PIN photodiodes on a flexible substrate poses significant challenges associated with the intrinsic film stress of amorphous silicon. This paper examines how altering device structuring and diode passivation layers can greatly improve the electrical performance and the mechanical reliability of the device, thereby eliminating one of the major weaknesses of a-Si PIN diodes in comparison to alternative photodetector technology, such as organic bulk heterojunction photodiodes and amorphous selenium. A dark current of 0.5 pA/mm² and photodiode quantum efficiency of 74% are possible with a pixelated diode structure with a silicon nitride/SU-8 bilayer passivation structure on a 20 µm-thick polyimide substrate.

  10. SAPHIRE (scintillator avalanche photoconductor with high resolution emitter readout) for low dose x-ray imaging: Spatial resolution

    OpenAIRE

    2008-01-01

    An indirect flat panel imager (FPI) with programmable avalanche gain and field emitter array (FEA) readout is being investigated for low-dose and high resolution x-ray imaging. It is made by optically coupling a structured x-ray scintillator, e.g., thallium (Tl) doped cesium iodide (CsI), to an amorphous selenium (a-Se) avalanche photoconductor called high-gain avalanche rushing amorphous photoconductor (HARP). The charge image created by the scintillator∕HARP (SHARP) combination is read out ...

  11. 21 CFR 573.920 - Selenium.

    Science.gov (United States)

    2010-04-01

    ..., AND RELATED PRODUCTS FOOD ADDITIVES PERMITTED IN FEED AND DRINKING WATER OF ANIMALS Food Additive... Act; unless the Commissioner of Food and Drugs makes a determination that: (1) Selenium additives are... additive; (4) selenium at such levels does not achieve its intended effect of promoting normal growth...

  12. Learning selenium testing tools with Python

    CERN Document Server

    Gundecha, Unmesh

    2014-01-01

    If you are a quality testing professional, or a software or web application developer looking to create automation test scripts for your web applications, with an interest in Python, then this is the perfect guide for you. Python developers who need to do Selenium testing need not learn Java, as they can directly use Selenium for testing with this book.

  13. Comparison of image quality using a X-ray stereotactical whole-body system and a direct flat-panel X-ray device in examinations of the pelvis and knee; Bildqualitativer Vergleich eines roentgenstereotaktischen Ganzkoerperaufnahmesystems mit der direkten Flachdetektor-Radiografie anhand von Untersuchungen des Beckens und des Knies

    Energy Technology Data Exchange (ETDEWEB)

    Krug, K.B.; Weber, C.; Schwabe, H. [Klinikum der Koeln Univ. (Germany). Inst. fuer Radiologische Diagnostik; and others

    2014-01-15

    Purpose: The novel biplanar X-ray unit 'EOS', EOS Imaging, allows to acquire simultaneously 2 perpendicular planes of full-length spine and limbs and to measure spatially correct angles based on the acquired image data sets. This is to be seen alongside with a low spatial resolution, high investment costs and high operating expenses. The use of the biplanar X-ray unit in morphology based skeletal radiography might improve the cost-benefit-relation. Thus, the purpose of this study was to compare image quality of the EOS-unit and the flat panel (FP)-technology as reference in a clinical setting. Materials and Methods: All 114 patients of the Orthopedic Hospital Dept., who had a biplanar full-length lower limb radiograph and a FP-examination of the pelvis and/or the knee with maximum time interval of 3 months without changes in the clinical and radiological findings were included in the study. All X-ray examinations had been carried out due to clinical indications. Secondary captures comparable to the FP-images were extracted from the electronic EOS-image data sets. 4 radiologists independently from each other compared the visualization of normal anatomical structures of the pseudonymous EOS- and FP-images in a randomized order. Results: In the overview of all readers and all skeletal regions image quality of the FP-images was considered being superior in a mean of 83 {+-} 13 % standard deviation of the pair comparisons (minimum 48 %, maximum 100 %). Image quality of the EOS-images was assessed as being superior in 2 {+-} 3 % of the cases (0 %, 10 %). Image quality of 0.8 {+-} 3 % of the FP-images (0 %, 17 %) and 30 {+-} 34 % (0 %, 100 %) of the EOS-images was estimated as diagnostically inadequate. 30 {+-} 33 % of the pair comparisons (0 %, 100 %) showed a diagnostically inadequate image quality of the EOS-images and a diagnostically good image quality of the FP-images. Conclusion: Image quality of biplanar full-length lower limb X-ray examinations is not

  14. Advanced prostate cancer risk in relation to toenail selenium levels

    NARCIS (Netherlands)

    Geybels, M.S.; Verhage, B.A.J.; Schooten, F.J. van; Goldbohm, A.; Brandt, P.A. van den

    2013-01-01

    BACKGROUND: Selenium may prevent advanced prostate cancer (PCa), but most studies on this topic were conducted in populations with moderate to high selenium status. We investigated the association of toenail selenium, reflecting long-term selenium exposure, and advanced PCa risk in a population from

  15. Biosynthesis of selenium nanoparticles by Pantoea agglomerans and their antioxidant activity

    Energy Technology Data Exchange (ETDEWEB)

    Torres, S. K.; Campos, V. L., E-mail: vcampos@udec.cl; Leon, C. G. [Universidad de Concepcion, Laboratorio de Microbiologia Ambiental, Departamento de Microbiologia (Chile); Rodriguez-Llamazares, S. M. [Centro de Investigacion de Polimeros Avanzados (CIPA) (Chile); Rojas, S. M.; Gonzalez, M. [Universidad de Concepcion, Laboratorio de Fisiologia Vascular, Departamento de Fisiologia (Chile); Smith, C. [Universidad de Concepcion, Departamento de Microbiologia (Chile); Mondaca, M. A. [Universidad de Concepcion, Laboratorio de Microbiologia Ambiental, Departamento de Microbiologia (Chile)

    2012-11-15

    The bio-reduction of selenite (Se (IV)) generates nanoparticles with sizes ranging between 30 and 300 nm. Biologic properties of Se nanoparticles, e.g., antioxidant activity, are dependent on the nanoparticle size; smaller particles have greater activity. In this study, the bio-reduction of selenite by Pantoea agglomerans strain UC-32 under aerobic conditions and room temperature to produce bioactive Se nanoparticles smaller than 100 nm was demonstrated. Isolation and purification of the nanoparticles was performed by alkaline lysis. These purified nanoparticles were stabilized with l-cysteine (4 mM). The visualization and characterization of nanoparticles were performed by transmission electron microscopy, energy dispersive X-ray spectroscopy, and scanning electron microscopy. The antioxidant activity of nanoparticles was determined by production of reactive oxygen species using human umbilical vein endothelial cells. Transmission electron microscopy images showed the accumulation of spherical selenium nanoparticles as intracellular and extracellular deposits. The size of Se nanoparticles varied with incubation time. Amorphous Se nanoparticles with size in the order of 100 nm were obtained before 24 h of incubation; but, at 24 h of incubation, the size of the majority of the nanoparticles was in the desirable order of 100 nm and they were not aggregated. Energy dispersive spectroscopy spectra indicated that nanoparticles were composed entirely of selenium. Antioxidant activity of stabilized selenium nanoparticles demonstrated high antioxidant activity when compared to selenite and selenium nanoparticles without stabilization. Stabilized biologically synthetized selenium (0) nanoparticles with size less than 100 nm have a potential application as a food additive with antioxidant properties relevant to human health.

  16. Properties of amorphous carbon

    CERN Document Server

    2003-01-01

    Amorphous carbon has a wide range of properties that are primarily controlled by the different bond hydridisations possible in such materials. This allows for the growth of an extensive range of thin films that can be tailored for specific applications. Films can range from those with high transparency and are hard diamond-like, through to those which are opaque, soft and graphitic-like. Films with a high degree of sp3 bonding giving the diamond-like properties are used widely by industry for hard coatings. Application areas including field emission cathodes, MEMS, electronic devices, medical and optical coatings are now close to market. Experts in amorphous carbon have been drawn together to produce this comprehensive commentary on the current state and future prospects of this highly functional material.

  17. Magnetostrictive amorphous bimetal sensors

    CERN Document Server

    Mehnen, L; Kaniusas, E

    2000-01-01

    The paper describes the application of a magnetostrictive amorphous ribbon (AR) for the detection of bending. In order to increase sensitivity, a bimetal structure is used which consists of AR and a nonmagnetic carrier ribbon. Several methods for the preparation of the bimetal are discussed. Results of the bending sensitivities are given for various combinations of the material types indicating crucial problems of bimetal preparation.

  18. Blood selenium levels and contribution of food groups to selenium intake in adolescent girls in Iceland

    Directory of Open Access Journals (Sweden)

    Ingibjorg Gunnarsdottir

    2012-08-01

    Full Text Available Background/objectives: Significant changes have been reported in dietary habits and food availability in Iceland that would be expected to compromise selenium intake and status, especially among young people. These include substantial decreases in the consumption of fish and milk, as well as the selenium content of imported wheat. The aim of this study was to assess selenium in the diet and whole blood of adolescent girls, as well as define the most important foods contributing to intake and blood concentrations of selenium. Design: The subjects were 96 randomly selected girls, aged 16–20, who answered a validated food frequency questionnaire (FFQ for dietary assessment. Selenium intake from each food group was calculated in µg/day. Blood samples were collected for measurement of whole blood selenium. Results: Mean dietary selenium was 51±25 µg/day. Milk/dairy products, including cheese, contributed 36±14% of total dietary selenium; fish 18±12%; and bread/cereal products 13±6%. Mean whole blood selenium was 117±12 µg/l (range 90–208; nearly 90% of subjects were above the optimal level of 100 µg/l. Fish and bread/cereal products were the only foods significantly correlated with selenium in blood (r=0.32; P = 0.002 and r=0.22; P = 0.04, respectively while no correlation was found with milk and dairy products in spite of their greater contribution to total selenium intake. Conclusion: In this population of Icelandic adolescent girls, selenium intake and status seem acceptable. Judging from associations between intake and blood levels, fish and cereals may be the most important contributors to blood selenium.

  19. Selenium in Cattle: A Review

    Directory of Open Access Journals (Sweden)

    Youcef Mehdi

    2016-04-01

    Full Text Available This review article examines the role of selenium (Se and the effects of Se supplementation especially in the bovine species. Selenium is an important trace element in cattle. Some of its roles include the participation in the antioxidant defense the cattle farms. The nutritional requirements of Se in cattle are estimated at 100 μg/kg DM (dry matter for beef cattle and at 300 μg/kg DM for dairy cows. The rations high in fermentable carbohydrates, nitrates, sulfates, calcium or hydrogen cyanide negatively influence the organism’s use of the selenium contained in the diet. The Se supplementation may reduce the incidence of metritis and ovarian cysts during the postpartum period. The increase in fertility when adding Se is attributed to the reduction of the embryonic death during the first month of gestation. A use of organic Se in feed would provide a better transfer of Se in calves relative to mineral Se supplementation. The addition of Se yeasts in the foodstuffs of cows significantly increases the Se content and the percentage of polyunsaturated fatty acids (PUFA in milk compared to the addition of sodium selenite. The enzyme 5-iodothyronine deiodinase is a seleno-dependent selenoprotein. It is one of the last proteins to be affected in the event of Se deficiency. This delay in response could explain the fact that several studies did not show the effect of Se supplementation on growth and weight gain of calves. Enrichment of Se in the diet did not significantly affect the slaughter weight and carcass yield of bulls. The impact and results of Se supplementation in cattle depend on physiological stage, Se status of animals, type and content of Se and types of Se administration. Further studies in Se supplementation should investigate the speciation of Se in food and yeasts, as well as understanding their metabolism and absorption. This constitute a path to exploit in order to explain certain different effects of Se.

  20. In Situ Immobilization of Selenium in Sediment

    Energy Technology Data Exchange (ETDEWEB)

    Moore, Robert C. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Stewart, Thomas Austin [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2014-09-01

    This project focused on the use of a sorbent, carbonated apatite, to immobilize selenium in the environment. It is know that apatite will sorb selenium and based on the mechanism of sorption it is theorized that carbonated apatite will be more effective that pure apatite. Immobilization of selenium in the environment is through the use of a sorbent in a permeable reactive barrier (PRB). A PRB can be constructed by trenching and backfill with the sorbent or in the case of apatite as the sorbent formed in situ using the apatite forming solution of Moore (2003, 2004). There is very little data on selenium sorption by carbonated apatite in the literature. Therefore, in this work, the basic sorptive properties of carbonated apatite were investigated. Carbonated apatite was synthesized by a precipitation method and characterized. Batch selenium kinetic and equilibrium experiments were performed. The results indicate the carbonated apatite contained 9.4% carbonate and uptake of selenium as selenite was rapid; 5 hours for complete uptake of selenium vs. more than 100 hours for pure hydroxyapatite reported in the literature. Additionally, the carbonated apatite exhibited significantly higher distribution coefficients in equilibrium experiments than pure apatite under similar experimental conditions. The next phase of this work will be to seek additional funds to continue the research with the goal of eventually demonstrating the technology in a field application.

  1. Selenium in human male reproductive organs.

    Science.gov (United States)

    Oldereid, N B; Thomassen, Y; Purvis, K

    1998-08-01

    The objective of the study was to obtain information on the concentration and distribution of selenium throughout the human male reproductive tract. Material was removed at autopsy from 41 men who had died suddenly and unexpectedly. Semen samples were also provided from 184 men attending an andrology clinic for fertility investigation and from 32 healthy volunteers. Significant positive correlations in the selenium concentration were demonstrated between the different reproductive organs, the testis having the highest concentrations. No correlation was found between the concentration of selenium in the genital organs and liver, kidney or blood, suggesting that its uptake and/or biochemical activity in the reproductive organs may be controlled by similar mechanisms not shared by the other organs. No significant age-dependent changes could be detected in tissue selenium concentrations. In a group of men under fertility investigation, a significant positive correlation was obtained between seminal plasma concentrations of selenium and concentrations of spermatozoa in the same ejaculate. A significant positive correlation between concentrations of zinc and selenium in the same ejaculates indicated that selenium may arise largely from the prostate gland.

  2. Comparison of the electrical and optical properties of direct current and radio frequency sputtered amorphous indium gallium zinc oxide films

    Energy Technology Data Exchange (ETDEWEB)

    Yao, Jianke, E-mail: yaojk@pkusz.edu.cn [School of Computer and Information Engineering, Shenzhen Graduate School of Peking University, Shenzhen 518055 (China); Gong, Li [Instrumental Analysis and Research Center, Sun Yat-Sen University, Guangzhou 10275 (China); Xie, Lei [School of Computer and Information Engineering, Shenzhen Graduate School of Peking University, Shenzhen 518055 (China); Zhang, Shengdong, E-mail: zhangsd@pku.edu.cn [School of Computer and Information Engineering, Shenzhen Graduate School of Peking University, Shenzhen 518055 (China); Institute of Microelectronics, Peking University, Beijing 100871 (China)

    2013-01-01

    The electrical and optical properties of direct current and radio frequency (RF) sputtered amorphous indium gallium zinc oxide (a-IGZO) films are compared. It is found that the RF sputtered a-IGZO films have better stoichiometry (In:Ga:Zn:O = 1:1:1:2.5–3.0), lower electrical conductivity (σ < 8 S/cm), higher refractive index (n = 1.9–2.0) and larger band gap (E{sub g} = 3.02–3.29 eV), and show less shift of Fermi level (△ E{sub F} ∼ 0.26 eV) and increased concentration of electrons (△ N{sub e} ∼ 10{sup 4}) in the conduction band with the reduction concentration of oxygen vacancy (V{sub O}). Although a-IGZO has intensively been studied for a semiconductor channel material of thin film transistors in next-generation flat panel displays, its fundamental material parameters have not been thoroughly reported. In this work, the work function (φ) of a-IGZO films is tested with the ultraviolet photoelectron spectroscopy. It is found that the φ of a-IGZO films is in the range of 4.0–5.0 eV depending on the V{sub O}. - Highlights: ► Amorphous InGaZnO{sub 4} (a-IGZO) films were prepared with different sputtering modes. ► Electrical and optical properties of the different films were compared. ► Fermi level (△E{sub F}) shift in a-IGZO films were tested by X-ray photoelectron spectroscopy. ► The relation of △E{sub F} with the properties of a-IGZO films were discussed. ► Work function was tested by ultraviolet photoelectron spectroscopy.

  3. Effects of SeleniumFertilizers on SeleniumContent and Nutrient Quality of Kiwifruit

    OpenAIRE

    LIU Hong-qin; Chen, Yue; Fang, Yong; Zhang, Jun; ZONG Liang-gang; SUN Hong-jie; Chen, Xi; Xue, Mei; Zhao, Fang-Jie; HU Qiu-hui

    2014-01-01

    The effects of different fertilization methods on selenium content and nutrition quality of kiwifruits were employed for selenium fortification. The fertilization methods were root fertilization, foliar fertilization and combined fertilization on their corresponding fertilizing periods. The results demonstrated that selenium content of these three experimental groups was in the order of foliar fertilization>combined fertilization>root fertilization. Foliar fertilization with the dose of 0.5 k...

  4. Selenium and Prostate Cancer Prevention: Insights from the Selenium and Vitamin E Cancer Prevention Trial (SELECT)

    OpenAIRE

    Nicastro, Holly L.; Dunn, Barbara K.

    2013-01-01

    The Selenium and Vitamin E Cancer Prevention Trial (SELECT) was conducted to assess the efficacy of selenium and vitamin E alone, and in combination, on the incidence of prostate cancer. This randomized, double-blind, placebo-controlled, 2 × 2 factorial design clinical trial found that neither selenium nor vitamin E reduced the incidence of prostate cancer after seven years and that vitamin E was associated with a 17% increased risk of prostate cancer compared to placebo. The null result was ...

  5. Uptake and metabolism of selenium by oysters

    Energy Technology Data Exchange (ETDEWEB)

    Wrench, J.J.

    1979-01-01

    Observation of the equilibration of /sup 75/Se with the tissues of Ostrea edulis suggested that the highest concentration factor occurred in the digestive gland. A study of the form of selenium in this tissue after assimilation of /sup 75/Se from water or labelled phytoplankton showed that the majority of selenium, in both cases, was strongly associated with protein. Enzymic hydrolysis of protein and subsequent chromatography of hydrolytic products revealed the presence of breakdown products of selenium analogues of the common sulphur amino acids.

  6. Encapsulation of selenium in chitosan nanoparticles improves selenium availability and protects cells from selenium-induced DNA damage response

    Science.gov (United States)

    Selenium, an essential mineral, plays important roles in optimizing human health. Chitosan is an effective, naturally oriented material for synthesizing nanoparticles with polyanions and exhibit preferable properties such as biocompatibility, biodegradation and resistance to certain enzymes. We have...

  7. Selenium: environmental significance, pollution, and biological treatment technologies.

    Science.gov (United States)

    Tan, Lea Chua; Nancharaiah, Yarlagadda V; van Hullebusch, Eric D; Lens, Piet N L

    2016-01-01

    Selenium is an essential trace element needed for all living organisms. Despite its essentiality, selenium is a potential toxic element to natural ecosystems due to its bioaccumulation potential. Though selenium is found naturally in the earth's crust, especially in carbonate rocks and volcanic and sedimentary soils, about 40% of the selenium emissions to atmospheric and aquatic environments are caused by various industrial activities such as mining-related operations. In recent years, advances in water quality and pollution monitoring have shown that selenium is a contaminant of potential environmental concern. This has practical implications on industry to achieve the stringent selenium regulatory discharge limit of 5μgSeL(-1) for selenium containing wastewaters set by the United States Environmental Protection Agency. Over the last few decades, various technologies have been developed for the treatment of selenium-containing wastewaters. Biological selenium reduction has emerged as the leading technology for removing selenium from wastewaters since it offers a cheaper alternative compared to physico-chemical treatments and is suitable for treating dilute and variable selenium-laden wastewaters. Moreover, biological treatment has the advantage of forming elemental selenium nanospheres which exhibit unique optical and spectral properties for various industrial applications, i.e. medical, electrical, and manufacturing processes. However, despite the advances in biotechnology employing selenium reduction, there are still several challenges, particularly in achieving stringent discharge limits, the long-term stability of biogenic selenium and predicting the fate of bioreduced selenium in the environment. This review highlights the significance of selenium in the environment, health, and industry and biotechnological advances made in the treatment of selenium contaminated wastewaters. The challenges and future perspectives are overviewed considering recent

  8. Application of flat-panel digital subtraction angiography in interventional therapy for carotid cavernous fistutas:initial clinical experience%平板DSA新技术在介入治疗颈内动脉海绵窦瘘中应用初探

    Institute of Scientific and Technical Information of China (English)

    石强; 梁传声; 臧培卓; 徐克

    2009-01-01

    Objective To assess the clinical value offlat-panel digital subtraction angiography (DSA)in interventional therapy for carotid-cavemous fistula (CCF). Methods Three-dimensional (3D)DSA Was performed in 12 patients with CCF before the interventional therapy.The fistular orifice was located and measured with multiplanar reconstruction technique,and the Landscap roadmap of the fistula was obtained.Fistula embolization was performed according to the location of the fistular orifice and the surrounding bony marker indicated by 3D and Landscap roadmap. Results The fistular orifices were clearly displayed in the 12 patients with an average orifice diameter of 3.7 mm.The intemal carotid artery(ICA)and the bony marker of the cavernous sinus were shown simultaneously.Ten patients received endovascular embolization wiith detachable balloon, and 1 patient was treated wiith coil and 1 with stent placement.The ICA remained patent in 11 cases and carotid artery occlusion was performed in 1 case. Conclusion The 3D flat-panel DSA provides rich infolrmati,Ion on the fistular orifice,,and the bony markers can be identified by landscape roadmap technique..The combination of these two techniques guarantees effective and safe treatment of CCE.%目的 探讨平板DSA新技术在介入治疗颈内动脉海绵窦瘘(CCF)中的应用价值.方法 12例CCF患者术前行3DDSA检查,应用多平面重建技术定位瘘口并对瘘口进行测量.治疗中利用可调控实时透视路途技术(Landscap技术)制作路径图,以3D图像所示瘘口及周围骨性标志作为对照进行封堵治疗.结果 12例CCF均可清晰定位瘘口,瘘口直径平均3.7 mm.利用Landscap技术使颈内动脉路径及海绵窦骨性标志同时可见.球囊栓塞10例,弹簧圈栓塞1例,支架封堵瘘口1例.颈内动脉通畅11例,1例行颈内动脉闭塞.结论 平板DSA 3D技术提供了瘘口的丰富信息,Landscap技术为治疗增加了骨性标志,其联合应用为治疗CCF提供了安全保障.

  9. Selenium in human milk and dietary selenium intake by Greeks.

    Science.gov (United States)

    Bratakos, M S; Ioannou, P V

    1991-06-01

    Fluorimetric determination of selenium in colostrum, transitional and mature human milk gave the following concentrations (mean and standard deviation): 41 +/- 16, 23 +/- 6 and 17 +/- 3 ng Se ml-1, respectively. The ranges for each kind of milk, especially for mature milk, were narrow. For all cases studied, the Se concentration in milk decreased with lactation time, reaching a plateau, at 17 ng Se ml-1, after 20 days. It is estimated that breast-fed-only babies in Greece receive approximately 5-11 micrograms Se day-1 up to 6 months of age. From consumed food data it was estimated that adult Greeks receive 100 +/- 6 micrograms Se day-1, in close agreement with our previously determined value of 110 micrograms Se day-1 estimated from food disappearance data.

  10. Complementary use of molecular and element-specific mass spectrometry for identification of selenium compounds related to human selenium metabolism

    Energy Technology Data Exchange (ETDEWEB)

    Gammelgaard, Bente; Gabel-Jensen, Charlotte; Stuerup, Stefan; Hansen, Helle R. [University of Copenhagen, Department of Pharmaceutics and Analytical Chemistry, Faculty of Pharmaceutical Sciences, Copenhagen (Denmark)

    2008-04-15

    The aim of this paper is to give an overview of analytical data on the identification of selenium compounds in biological samples with relevance for selenium metabolism. Only studies applying the combination of element-specific inductively coupled plasma mass spectrometry as well as molecular electrospray mass spectrometry detection have been included. Hence, selenium compounds are only considered identified if molecular mass spectra obtained by analysis of the authentic biological sample have been provided. Selenium compounds identified in selenium-accumulating plants and yeast are included, as extracts from such plants and yeast have been widely used for examination of the cancer-preventive effect of selenium in cell lines, animal models and human intervention trials. Hence, these selenium compounds are available for absorption and further metabolism. Identification of selenium metabolites in simulated gastric and intestinal juice, intestinal epithelial tissue, liver and urine is described. Hence, selenium metabolites identified in relation to absorption, metabolism and excretion are included. (orig.)

  11. Reproductive impacts of elevated selenium levels

    Data.gov (United States)

    US Fish and Wildlife Service, Department of the Interior — The objectives of this study were to: 1. Evaluate selenium levels in Neotropical migrants and riparian obligate birds on Imperial National Wildlife Refuge. 2....

  12. Review of selenium and prostate cancer prevention.

    Science.gov (United States)

    Yang, Lei; Pascal, Mouracade; Wu, Xiao-Hou

    2013-01-01

    Prostate cancer is the most common malignancy in men in the United States. Surgery or radiation are sometimes unsatisfactory treatments because of the complications such as incontinence or erectile dysfunction. Selenium was found to be effective to prevent prostate cancer in the Nutritional Prevention of Cancer Trial (NPC), which motivated two other clinical trials: the Selenium and Vitamin E Cancer Prevention Trial (SELECT) and a Phase III trial of selenium to prevent prostate cancer in men with high-grade prostatic intraepithelial neoplasia. However, these two trials failed to confirm the results of the NPC trial and indicated that the selenium may not be preventive of prostate cancer. In this article we review the three clinical trials and discuss some different points which might be potential factors underlying variation in results obtained.

  13. Biofortification and phytoremediation of selenium in China

    Science.gov (United States)

    Biofortification is an agricultural process that increases the uptake and accumulation of specific nutrients, e.g. selenium (Se), in agricultural food products through plant breeding, genetic engineering, and manipulation of agronomic practices. The development and uses of biofortified agricultural ...

  14. Selenium supplementation for patients with Graves’ hyperthyroidism (the GRASS trial)

    DEFF Research Database (Denmark)

    Watt, Torquil; Cramon, Per; Bjorner, Jakob Bue

    2013-01-01

    Graves' hyperthyroidism is an autoimmune disease causing hyperfunction of the thyroid gland. The concentration of selenium is high in the thyroid gland and two important groups of enzymes within the thyroid are selenoproteins, that is, they depend on selenium. Selenium may have beneficial effects...... on autoimmune hypothyroidism and on Graves' orbitopathy, but the effects of selenium on Graves' hyperthyroidism is unknown.We hypothesize that adjuvant selenium may be beneficial in the treatment of Graves' hyperthyroidism. The objective is to investigate if selenium supplementation plus standard treatment......, anti-thyroid drug treatment success), and improved quality of life in patients with Graves' hyperthyroidism....

  15. Biomarkers of selenium status in dogs

    OpenAIRE

    Van Zelst, Marielle; Hesta, Myriam; Gray, Kerry; Staunton, Ruth; Du Laing, Gijs; Janssens, Geert

    2016-01-01

    Background: Inadequate dietary selenium (Se) intake in humans and animals can lead to long term health problems, such as cancer. In view of the owner's desire for healthy longevity of companion animals, the impact of dietary Se provision on long term health effects warrants investigation. Little is currently known regards biomarkers, and rate of change of such biomarkers in relation to dietary selenium intake in dogs. In this study, selected biomarkers were assessed for their suitability to d...

  16. The role of selenium in predicting preeclampsia

    Directory of Open Access Journals (Sweden)

    Z Ghaemi

    2013-10-01

    Full Text Available Introduction: Preeclampsia is a common disorder that is a leading cause of perinatal and maternal morbidity and mortality; however its specific etiology has still remained obscure.The first step in preventing preeclampsia is early detection of women at risk. Since there is no valid and reliable screening test, appropriate diagnostic and screening tests are necessary, which are inexpensive, non-invasive and beneficial for pregnant women. Therefore, regarding the role of selenium as an antioxidant in the prevention preeclampsia, this study was designed which aimed to determine the prognostic value of plasma selenium levels in the diagnosis of preeclampsia in primigravida women Methods: In a nested case control design, a sample of 650 normal primigravida women of 24-28 weeks participated in the study. Subjects who involved the case group were followed up for 3 months and 38 were affected by preeclampsia. Blood samples were obtained from these 38patients as well as from 38 subjects as their matched controls. Moreover, the amount of selenium was measured by atomic absorption spectrometry. Results: The mean level of selenium in blood plasma of the cases was significantly lower than in their matched controls. The present study findings revealed that pregnant women with serum Se < 66.1 μg/L had a significantly increased risk of preeclampsia. Conclusion: Lower plasma selenium level in women destines to suffering from preeclampsia which confirms the destructive effect of selenium deficiency as an antioxidant in etiopathology of preeclampsia. Measurement of plasma selenium can improve the prediction of preeclampsia; thus, it seems that plasma selenium level test owns an acceptable sensitivity and specificity for predicting preeclampsia.

  17. Zinc, copper and selenium in reproduction.

    Science.gov (United States)

    Bedwal, R S; Bahuguna, A

    1994-07-15

    Of the nine biological trace elements, zinc, copper and selenium are important in reproduction in males and females. Zinc content is high in the adult testis, and the prostate has a higher concentration of zinc than any other organ of the body. Zinc deficiency first impairs angiotensin converting enzyme (ACE) activity, and this in turn leads to depletion of testosterone and inhibition of spermatogenesis. Defects in spermatozoa are frequently observed in the zinc-deficient rat. Zinc is thought to help to extend the functional life span of the ejaculated spermatozoa. Zinc deficiency in the female can lead to such problems as impaired synthesis/secretion of (FSH) and (LH), abnormal ovarian development, disruption of the estrous cycle, frequent abortion, a prolonged gestation period, teratogenicity, stillbirths, difficulty in parturition, pre-eclampsia, toxemia and low birth weights of infants. The level of testosterone in the male has been suggested to play a role in the severity of copper deficiency. Copper-deficient female rats are protected against mortality due to copper deficiency, and the protection has been suggested to be provided by estrogens, since estrogens alter the subcellular distribution of copper in the liver and increase plasma copper levels by inducing ceruloplasmin synthesis. The selenium content of male gonads increases during pubertal maturation. Selenium is localized in the mitochondrial capsule protein (MCP) of the midpiece. Maximal incorporation in MCP occurs at steps 7 and 12 of spermatogenesis and uptake decreases by step 15. Selenium deficiency in females results in infertility, abortions and retention of the placenta. The newborns from a selenium-deficient mother suffer from muscular weakness, but the concentration of selenium during pregnancy does not have any effect on the weight of the baby or length of pregnancy. The selenium requirements of a pregnant and lactating mother are increased as a result of selenium transport to the fetus via

  18. Dietary Selenium and Human Health

    Directory of Open Access Journals (Sweden)

    Lutz Schomburg

    2016-12-01

    Full Text Available Next year (2017, the micronutrient Selenium (Se is celebrating its birthday—i.e., 200 years after first being identified by the Swedish chemist Jöns Jakob Berzelius. Despite its impressive age, research into the functions of this essential trace element is very alive and reaching out for new horizons. This special issue presents some recent fascinating, exciting, and promising developments in Se research in the form of eight original contributions and seven review articles. Collectively, aspects of Se supply, biochemical, physiological, and chemotherapeutic effects, and geobiological interactions are covered by leading scientists in the areas of nutritional, basic, and clinical research. It is obvious from the contributions that the bicentennial anniversary will celebrate a micronutrient still in its infancy with respect to being understood in terms of its biomedical importance.

  19. Beyond amorphous organic semiconductors

    Science.gov (United States)

    Hanna, Jun-ichi

    2003-07-01

    Recently it has been discovered that some types of liquid crystals, which believed to be governed by ionic conduction, exhibit a very fast electronic conduction. Their charge carrier transport is characterized by high mobility over 10-2 cm2/Vs independent of electric field and temperature. Now, the liquid crystals are being recognized as a new class of organic semiconductors. In this article, a new aspect of liquid crystals as a self-organizing molecular semiconductor are reviewed, focused on their basic charge carrier transport properties and discussed in comparison with those of molecular crystals and amorphous materials. And it is concluded that the liquid crystal is promising as a quality organic semiconductor for the devices that require a high mobility.

  20. SELENIUM MOBILITY IN SOME SOILS OF ROMANIA

    Directory of Open Access Journals (Sweden)

    Mihaela Lungu

    2013-12-01

    Full Text Available Selenium mobility in soil depends on a multitude of physical and chemical factors. The present paper highlights the selenium solubilization degree out of the total soil content in relation with its agrochemical properties. Soils samples were considered collected from different agricultural areas of the Country, with or without certain natural handicaps, from soils under industrial impact and long term agrochemical experiments. The selenium solubilization percentages out of the soil total content ranged between 3.57 and 8.15%. No solubilization percentage was calculated for Central and Southern Dobrudja and the South-Eastern Romanian Plane, because the total selenium quantities in these areas are lower and mobile selenium values are very low. The statistical analysis of the calculated percentage values highlighted homogeneous areas and areas with a higher scattering degree. Thus, in agricultural land, in acknowledged agrarian areas and in long term agricultural experiments, the percentage values are better grouped, showing (expectable soil homogeneousness, on one hand, and a significant soil selenium supply and its adequate solubilization for plant nutrition, on the other. The most scattered values occurred in the Călmăţui and Buzău valleys area in halomorphic soils, and in the Făgăraş Depression which is under the industrial polluting influence of chemical works. Among the causes for these differences is the uniformity or non-uniformity of the terrains, induced by land use and the existence or not of a handicap (polluting impact or halomorphic soils, for example. In general, there are no significant differences between the selenium mobility values and their grouping or scattering degree in the soil depth. A single exception stands out, namely in the Făgăraş Depression, where the selenium solubilization degree tends to increase with soil depth, as well as the scattering degree. In the Danube Delta diked areas Sireasa and Pardina very

  1. Vitamin E, Selenium Don't Cut Colon Cancer Risk

    Science.gov (United States)

    ... page: https://medlineplus.gov/news/fullstory_162669.html Vitamin E, Selenium Don't Cut Colon Cancer Risk: ... 2016 WEDNESDAY, Dec. 21, 2016 (HealthDay News) -- Taking vitamin E and selenium does not appear to reduce ...

  2. Molecular targets of selenium in prostate cancer prevention (Review).

    Science.gov (United States)

    Abdulah, Rizky; Kobayashi, Kenji; Yamazaki, Chiho; Koyama, Hiroshi

    2011-08-01

    Prostate cancer is one of the leading causes of cancer-related deaths among males. Although use of the micro-nutrient selenium in prostate cancer clinical trials is limited, the outcomes indicate that selenium is a promising treatment. Furthermore, selenium inhibits prostate cancer through multiple mechanisms, and it is beneficial in controlling the development of this disease. This review highlights the latest epidemiological and biomolecular research on selenium in prostate cancer, as well as its prospects for future clinical use.

  3. Containerless processing of amorphous ceramics

    Science.gov (United States)

    Weber, J. K. Richard; Krishnan, Shankar; Schiffman, Robert A.; Nordine, Paul C.

    1990-01-01

    The absence of gravity allows containerless processing of materials which could not otherwise be processed. High melting point, hard materials such as borides, nitrides, and refractory metals are usually brittle in their crystalline form. The absence of dislocations in amorphous materials frequently endows them with flexibility and toughness. Systematic studies of the properties of many amorphous materials have not been carried out. The requirements for their production is that they can be processed in a controlled way without container interaction. Containerless processing in microgravity could permit the control necessary to produce amorphous forms of hard materials.

  4. Effect of selenium addition on the GeTe phase change memory alloys

    Energy Technology Data Exchange (ETDEWEB)

    Vinod, E.M., E-mail: vinuem@gmail.com [Department of Physics, Indian Institute of Science, Bangalore 560 012 (India); Singh, A.K.; Ganesan, R. [Department of Physics, Indian Institute of Science, Bangalore 560 012 (India); Sangunni, K.S., E-mail: sangu@physics.iisc.ernet.in [Department of Physics, Indian Institute of Science, Bangalore 560 012 (India)

    2012-10-05

    Highlights: Black-Right-Pointing-Pointer Selenium is used as an additive to GeTe phase change materials. Black-Right-Pointing-Pointer Crystalline structure of GeTe alloys does not affect up to 0.20 at.% of Se. Black-Right-Pointing-Pointer The possibility of Se occupying Ge vacancy sites in GeTe structure is explained. Black-Right-Pointing-Pointer Ge-Se and GeTe{sub 2} bonds increase with increase of Se concentration. Black-Right-Pointing-Pointer T{sub m} is reduced in 0.50 at.% Se alloy, which can reduce RESET current requirements. - Abstract: Compositional dependent investigations of the bulk GeTe chalcogenides alloys added with different selenium concentrations are carried out by X-ray diffraction (XRD), Raman spectroscopy, X-ray photoelectron spectroscopy (XPS), electron probe micro-analyzer (EPMA) and differential scanning calorimetry (DSC). The measurements reveal that GeTe crystals are predominant in alloys up to 0.20 at.% of Se content indicating interstitial occupancy of Se in the Ge vacancies. Raman modes in the GeTe alloys changes to GeSe modes with the addition of Se. Amorphousness in the alloy increases with increase of Se and 0.50 at.% Se alloy forms a homogeneous amorphous phase with a mixture of Ge-Se and Te-Se bonds. Structural changes are explained with the help of bond theory of solids. Crystallization temperature is found to be increasing with increase of Se, which will enable the amorphous stability. For the optimum 0.50 at.% Se alloy, the melting temperature has reduced which will reduce the RESET current requirement for the phase change memory applications.

  5. EURRECA—Estimating Selenium Requirements for Deriving Dietary Reference Values

    NARCIS (Netherlands)

    Hurst, R.; Collings, R.; Harvey, L.J.; King, M.; Hooper, L.; Bouwman, J.; Gurinovic, M.; Fairweather-Tait, S.J.

    2013-01-01

    Current reference values for selenium, an essential micronutrient, are based on the intake of selenium that is required to achieve maximal glutathione peroxidase activity in plasma or erythrocytes. In order to assess the evidence of relevance to setting dietary reference values for selenium, the EUR

  6. NAIL KERATIN AS MONITOR-TISSUE FOR SELENIUM EXPOSURE

    NARCIS (Netherlands)

    VANNOORD, PAH; MAAS, MJ; DEBRUIN, M

    1992-01-01

    Nail clippings might provide a way to monitor exposure to selenium in the recent past of an individual, since a clipping collected from a toe would reflect exposures months before actual clipping date. The relation between levels of exogenous selenium exposure and selenium levels in nail keratin was

  7. Selenium deficiency and the effects of supplementation on preterm infants

    Directory of Open Access Journals (Sweden)

    Renata Germano B. O. N. Freitas

    2014-03-01

    Full Text Available Objective: This study aimed to review the literature about blood concentrations of selenium associated with gestational age, feeding, supplementation and related clinical features in preterm infants. Data sources: Systematic review in the following databases: MEDLINE, PubMed, Google academics, SciELO. org, ScienceDirect (Elsevier and CINAHL-Plus with Full Text (EBSCO. Articles published up to January 2013 with the keywords "selenium deficiency", "selenium supplementation", "neonates", "infants", "newborn" and "preterm infants" were selected. Data synthesis: The studies reported that low blood selenium levels are associated with increased risk of respiratory diseases. Preterm infants, especially with low birth weight, presented lower selenium levels. Selenium deficiency has also been associated with the use of oral infant formula, enteral and parenteral nutrition (with or without selenium addition. The optimal dose and length of selenium supplementation is not well-established, since they are based only on age group and selenium ingestion by breastfed children. Furthermore, the clinical status of the infant affected by conditions that may increase oxidative stress, and consequently, selenium requirements is not taken into account. Conclusions: Prematurity and low birth weight can contribute to low blood selenium in premature infants. Selenium supplementation seems to minimize or prevent clinical complications caused by prematurity.

  8. 21 CFR 520.2100 - Selenium, vitamin E capsules.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Selenium, vitamin E capsules. 520.2100 Section 520...) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS ORAL DOSAGE FORM NEW ANIMAL DRUGS § 520.2100 Selenium, vitamin... to 1 milligram of selenium) and 56.2 milligrams of vitamin E (68 I.U.) (as d-alpha tocopheryl...

  9. Selenistasis: Epistatic Effects of Selenium on Cardiovascular Phenotype

    Directory of Open Access Journals (Sweden)

    Joseph Loscalzo

    2013-01-01

    Full Text Available Although selenium metabolism is intricately linked to cardiovascular biology and function, and deficiency of selenium is associated with cardiac pathology, utilization of selenium in the prevention and treatment of cardiovascular disease remains an elusive goal. From a reductionist standpoint, the major function of selenium in vivo is antioxidant defense via its incorporation as selenocysteine into enzyme families such as glutathione peroxidases and thioredoxin reductases. In addition, selenium compounds are heterogeneous and have complex metabolic fates resulting in effects that are not entirely dependent on selenoprotein expression. This complex biology of selenium in vivo may underlie the fact that beneficial effects of selenium supplementation demonstrated in preclinical studies using models of oxidant stress-induced cardiovascular dysfunction, such as ischemia-reperfusion injury and myocardial infarction, have not been consistently observed in clinical trials. In fact, recent studies have yielded data that suggest that unselective supplementation of selenium may, indeed, be harmful. Interesting biologic actions of selenium are its simultaneous effects on redox balance and methylation status, a combination that may influence gene expression. These combined actions may explain some of the biphasic effects seen with low and high doses of selenium, the potentially harmful effects seen in normal individuals, and the beneficial effects noted in preclinical studies of disease. Given the complexity of selenium biology, systems biology approaches may be necessary to reach the goal of optimization of selenium status to promote health and prevent disease.

  10. Apatite Formation from Amorphous Calcium Phosphate and Mixed Amorphous Calcium Phosphate/Amorphous Calcium Carbonate.

    Science.gov (United States)

    Ibsen, Casper J S; Chernyshov, Dmitry; Birkedal, Henrik

    2016-08-22

    Crystallization from amorphous phases is an emerging pathway for making advanced materials. Biology has made use of amorphous precursor phases for eons and used them to produce structures with remarkable properties. Herein, we show how the design of the amorphous phase greatly influences the nanocrystals formed therefrom. We investigate the transformation of mixed amorphous calcium phosphate/amorphous calcium carbonate phases into bone-like nanocrystalline apatite using in situ synchrotron X-ray diffraction and IR spectroscopy. The speciation of phosphate was controlled by pH to favor HPO4 (2-) . In a carbonate free system, the reaction produces anisotropic apatite crystallites with large aspect ratios. The first formed crystallites are highly calcium deficient and hydrogen phosphate rich, consistent with thin octacalcium phosphate (OCP)-like needles. During growth, the crystallites become increasingly stoichiometric, which indicates that the crystallites grow through addition of near-stoichiometric apatite to the OCP-like initial crystals through a process that involves either crystallite fusion/aggregation or Ostwald ripening. The mixed amorphous phases were found to be more stable against phase transformations, hence, the crystallization was inhibited. The resulting crystallites were smaller and less anisotropic. This is rationalized by the idea that a local phosphate-depletion zone formed around the growing crystal until it was surrounded by amorphous calcium carbonate, which stopped the crystallization.

  11. Amorphous drugs and dosage forms

    DEFF Research Database (Denmark)

    Grohganz, Holger; Löbmann, K.; Priemel, P.;

    2013-01-01

    formulation principles are needed to ensure the stability of amorphous drug forms. The formation of solid dispersions is still the most investigated approach, but additional approaches are desirable to overcome the shortcomings of solid dispersions. Spatial separation by either coating or the use of micro......The transformation to an amorphous form is one of the most promising approaches to address the low solubility of drug compounds, the latter being an increasing challenge in the development of new drug candidates. However, amorphous forms are high energy solids and tend to recry stallize. New......-containers has shown potential to prevent or delay recrystallization. Another recent approach is the formation of co-amorphous mixtures between either two drugs or one drug and one low molecular weight excipient. Molecular interactions between the two molecules provide an energy barrier that has to be overcome...

  12. Selenium and Prostate Cancer Prevention: Insights from the Selenium and Vitamin E Cancer Prevention Trial (SELECT

    Directory of Open Access Journals (Sweden)

    Holly L. Nicastro

    2013-04-01

    Full Text Available The Selenium and Vitamin E Cancer Prevention Trial (SELECT was conducted to assess the efficacy of selenium and vitamin E alone, and in combination, on the incidence of prostate cancer. This randomized, double-blind, placebo-controlled, 2 × 2 factorial design clinical trial found that neither selenium nor vitamin E reduced the incidence of prostate cancer after seven years and that vitamin E was associated with a 17% increased risk of prostate cancer compared to placebo. The null result was surprising given the strong preclinical and clinical evidence suggesting chemopreventive activity of selenium. Potential explanations for the null findings include the agent formulation and dose, the characteristics of the cohort, and the study design. It is likely that only specific subpopulations may benefit from selenium supplementation; therefore, future studies should consider the baseline selenium status of the participants, age of the cohort, and genotype of specific selenoproteins, among other characteristics, in order to determine the activity of selenium in cancer prevention.

  13. Speciation of selenium dietary supplements; formation of S-(methylseleno)cysteine and other selenium compounds

    Energy Technology Data Exchange (ETDEWEB)

    Amoako, Prince O. [Department of Chemistry, University of Massachusetts Amherst, 710 N. Pleasant St., Amherst, MA 01003-9336 (United States); Uden, Peter C., E-mail: pcuden@chem.umass.edu [Department of Chemistry, University of Massachusetts Amherst, 710 N. Pleasant St., Amherst, MA 01003-9336 (United States); Tyson, Julian F. [Department of Chemistry, University of Massachusetts Amherst, 710 N. Pleasant St., Amherst, MA 01003-9336 (United States)

    2009-10-12

    Speciation of selenium is of interest because it is both essential and toxic to humans, depending on the species and the amount ingested. Following indications that selenium supplementation could reduce the incidence of some cancers, selenium-enriched yeast and other materials have been commercialized as supplements. Most dramatically however, the SELECT trial that utilized L-selenomethionine as the active supplement was terminated in 2008 and there is much debate regarding both the planning and the results of efficacy studies. Further, since dietary supplements are not regulated as pharmaceuticals, there are concerns about the quality, storage conditions, stability and selenium content in selenium supplements. Enzymatic hydrolysis enabled selenium speciation profiles to be obtained by high performance liquid chromatography with inductively coupled plasma mass spectrometry (HPLC-ICP-MS) and following derivatization gas chromatography with atomic emission detection (GC-AED). Coated fiber solid phase microextraction (SPME) was used to extract volatile selenium species for determination by GC-AED and GC-MS. Similar speciation patterns were observed between yeast-based supplements subject to extended storage and those heated briefly at elevated temperatures. All the yeast-based supplements and one yeast-free supplement formed S-(methylseleno)cysteine on heating. Evidence was obtained in support of the hypotheses that S-(methylseleno)cysteine is formed from a reaction between dimethyldiselenide and cysteine or cystine.

  14. Serum selenium levels and prostate cancer risk

    Science.gov (United States)

    Cui, Zhigang; Liu, Dezhong; Liu, Chun; Liu, Gang

    2017-01-01

    Abstract Some observational studies have shown that elevated serum selenium levels are associated with reduced prostate cancer risk; however, not all published studies support these results. A literature search of PubMed, Embase, Medline, and the Cochrane Library up until September 2016 identified 17 studies suitable for further investigation. A meta-analysis was conducted on these studies to investigate the association between serum selenium levels and subsequent prostate cancer risk. Pooled odds ratios (ORs) and 95% confidence intervals (CIs) were used to evaluate the overall OR of prostate cancer for the highest versus the lowest levels of serum selenium. We found a pooled OR (95% CI) of 0.76 (0.64, 0.91; P selenium levels and prostate cancer risk was found in each of case–control studies, current and former smokers, high-grade cancer cases, advanced cancer cases, and different populations. Such correlations were not found for subgroups containing each of cohort studies, nonsmokers, low-grade cancer cases, and early stage cancer cases. In conclusion, our study suggests an inverse relationship between serum selenium levels and prostate cancer risk. However, further cohort studies and randomized control trials based on non-Western populations are required. PMID:28151881

  15. Loss of selenium-binding protein 1 decreases sensitivity to clastogens and intracellular selenium content in HeLa cells

    Science.gov (United States)

    Selenium-binding protein 1 (SBP1) is not a selenoprotein but structurally binds selenium. Loss of SBP1 during carcinogenesis usually predicts poor prognosis. Because genome instability is a hallmark of cancer, we hypothesized that loss of SBP1 modulates cellular selenium content and the response of ...

  16. Selenium and selenocysteine: roles in cancer, health, and development.

    Science.gov (United States)

    Hatfield, Dolph L; Tsuji, Petra A; Carlson, Bradley A; Gladyshev, Vadim N

    2014-03-01

    The many biological and biomedical effects of selenium are relatively unknown outside the selenium field. This fascinating element, initially described as a toxin, was subsequently shown to be essential for health and development. By the mid-1990s selenium emerged as one of the most promising cancer chemopreventive agents, but subsequent human clinical trials yielded contradictory results. However, basic research on selenium continued to move at a rapid pace, elucidating its many roles in health, development, and in cancer prevention and promotion. Dietary selenium acts principally through selenoproteins, most of which are oxidoreductases involved in diverse cellular functions.

  17. [The importance of selenium in Hashimoto's disease].

    Science.gov (United States)

    Zagrodzki, Paweł; Kryczyk, Jadwiga

    2014-09-12

    The aim of this study was to present the current state of knowledge on the role of selenium in the treatment of Hashimoto's disease. In recent years, the number of cases of autoimmune Hashimoto's thyroiditis - a chronic disease that usually leads to hypothyroidism - has increased. Most patients have elevated levels of anti-TPO antibodies. The presence of these antibodies has an effect on subsequent thyroid damage. So far we have not developed an effective, standard therapy of this disease. However, more attention is being paid to the relationship between supplementation of selenium deficiency and inhibition of production of anti-TPO antibodies in patients with Hashimoto's thyroiditis. Therefore, selenium supplementation may be an effective option in the treatment of this disease.

  18. Selenium and Thyroid Disease: From Pathophysiology to Treatment

    Science.gov (United States)

    Ventura, Mara; Carrilho, Francisco

    2017-01-01

    Introduction. Selenium is a micronutrient embedded in several proteins. In adults, the thyroid is the organ with the highest amount of selenium per gram of tissue. Selenium levels in the body depend on the characteristics of the population and its diet, geographic area, and soil composition. In the thyroid, selenium is required for the antioxidant function and for the metabolism of thyroid hormones. Methods. We performed a review of the literature on selenium's role in thyroid function using PubMed/MEDLINE. Results. Regarding thyroid pathology, selenium intake has been particularly associated with autoimmune disorders. The literature suggests that selenium supplementation of patients with autoimmune thyroiditis is associated with a reduction in antithyroperoxidase antibody levels, improved thyroid ultrasound features, and improved quality of life. Selenium supplementation in Graves' orbitopathy is associated with an improvement of quality of life and eye involvement, as well as delayed progression of ocular disorders. The organic form of selenium seems to be the preferable formulation for supplementation or treatment. Conclusion. Maintaining a physiological concentration of selenium is a prerequisite to prevent thyroid disease and preserve overall health. Supplementation with the organic form is more effective, and patients with autoimmune thyroiditis seem to have benefits in immunological mechanisms. Selenium supplementation proved to be clinically beneficial in patients with mild to moderate Graves' orbitopathy. PMID:28255299

  19. [The role of selenium in endocrine system diseases].

    Science.gov (United States)

    Balázs, Csaba; Rácz, Károly

    2013-10-13

    Oxygen derived free radicals, generated by a number of cellular reactions, include superoxide anion, hydrogen peroxide and hydroxyl radicals. They exert their cytotoxic effects mainly via peroxidation of the cell membrane resulting in the loss of membrane integrity. The essential trace element, selenium exerts complex effects on the endocrine systems, partly due to its antioxidant capacity. Well-characterized selenoproteins include iodothyronine deiodinases, glutathione peroxidases and thioredoxin reductases involved in thyroid hormone metabolism and protection from oxidative damage. The value of selenium supplementation in autoimmune thyroid disorders has been investigated and most studies confirmed the beneficial effect of selenium supplementation in Hashimoto's and Graves's diseases. Recently, selenium proved to be effective in mild inflammatory orbitopathy. There are a number of reports about the effect of selenium in diabetes mellitus, but the data are controversial as both insulin-like and diabetes-inducing effects of selenium have been described. Selenium was successfully used in both female and male infertility of autoimmune origin.

  20. Selenium speciation in ground water. Quarterly report

    Energy Technology Data Exchange (ETDEWEB)

    Atalay, A.

    1990-07-10

    Selenium toxicity diseases in animals may occur when the intake exceeds 4 mg/kg and selenium deficiency symptoms may occur when dietary intake is less than 0.04 mg/kg. Since the selenium dietary requirement is very close to toxic concentration, it is important to understand the distribution of selenium in the environment. Selenium occurs in four oxidation states (-II, 0, +IV, and +VI) as selenide, elemental selenium, selenite and selenate. Selenate is reported as more soluble and less adsorbed than selenite. Selenate is more easily leached from soils and is the most available form for plants. Increased mobility of Se into the environment via anthropogenic activities, and the potential oxidation-reduction behavior of the element have made it imperative to study the aquatic chemistry of Se. For this purpose, Se species are divided into two different categories: dissolved Se (in material that passes through filters with 0.45 u openings) and particulate Se (in material of particle size > 0.45 mm) typically suspended sediment and other suspended solids. Element and colloidal phase, not truly dissolved, but passing through the filter is deemed to consist of selenium (-2,0). In dissolved state selenium may exist in three of its four oxidation states; Se(-II), Se(+IV), and Se(+VI). Particulate Se may exist in the same oxidation states as dissolved Se and can be found in different phases of the particulate matter. In sediments, Se may be within the organic material, iron and manganese oxides, carbonates or other mineral phases. The actual chemical forms of Se may be adsorbed to or coprecipitated with these phases (primarily selenite, SeO{sub 3}{sup 2{minus}}) and selenate, SeO{sub 4}{sup 2{minus}}. Selenide, Se(-II), can be covalently bound in the organic portion of a sediment. In addition, Se may be found in anoxic sediments as insoluble metal selenide precipitates, an insoluble elemental Se or as ferroselite (FeSe{sub 2}) and Se containing pyrite.

  1. Selenium supplementation in radiotherapy patients: do we need to measure selenium levels in serum or blood regularly prior radiotherapy?

    Science.gov (United States)

    Muecke, Ralph; Micke, Oliver; Schomburg, Lutz; Kisters, Klaus; Buentzel, Jens; Huebner, Jutta; Kriz, Jan

    2014-12-16

    Considering the review by Puspitasari and colleagues, an additional discussion of the endpoints of the Se supplementation studies described would be helpful. In our view, selenium can safely be given to selenium-deficient cancer patients prior to and during radiotherapy. Therefore, in order to help the radiation oncologist in decision making, we strongly advocate to determine the selenium status prior to and during a potential adjuvant selenium supplementation, e.g. when trying to ease the side-effects of radiation treatment or in the aftercare situation when the selenium status may become insufficient.

  2. Investigation of the crystallization process of amorphous silicon thin films%非晶硅薄膜晶化过程的研究

    Institute of Scientific and Technical Information of China (English)

    黄木香; 杨琳; 刘玉琪; 王江涌

    2012-01-01

    Polycrystalline silicon thin film is a high quality material for micro - electronic components, thin film transistors and large flat-panel LCD displays because of its high electrical mobility and stable photoelectric properties. Moreover, it has been regarded as a candidate material for making high efficiency, lower energy consumption and optimized thin film solar cells. Therefore, how to fabricate polycrystalline silicon thin film is a very meaningful research topic. Solid phase crystallization is a usual method to fabricate polycrystalline silicon thin film, by high temperature annealing to transfer amorphous film to polycrystalline phase, In this paper, the solid phase crystallization process of amorphous silicon thin films fabricated by different techniques are studied systematically by XRD and Raman spectroscopy.%多晶硅薄膜具有较高的电迁移率和稳定的光电性能,是制备微电子器件、薄膜晶体管、大面积平板液晶显示的优质材料.多晶硅薄膜被公认为是制备高效、低耗、最理想的薄膜太阳能电池的材料.因此,如何制备多晶硅薄膜是一个非常有意义的研究课题.固相法是制备多晶硅薄膜的一种常用方法,它是在高温退火的条件下,使非晶硅薄膜通过固相相变而成为多晶硅薄膜.本文采用固相法,利用X-ray衍射及拉曼光谱,对用不同方法制备的非晶硅薄膜的晶化过程进行了系统地研究.

  3. In vivo and in vitro testing for selenium and selenium compounds bioavailability assessment in foodstuff.

    Science.gov (United States)

    Moreda-Piñeiro, Jorge; Moreda-Piñeiro, Antonio; Bermejo-Barrera, Pilar

    2017-03-04

    The assessment of selenium and selenium species bioavailability in foodstuff is of special concern on the context of human nutrition. In vivo (human and animal), and in vitro tests are important approaches for estimating the bioavailability of toxic and essential compounds to humans. An overview on in vivo and in vitro bioavailability assays for releasing selenium and selenium species in foodstuffs is summarized. Se and Se species content in a foodstuff critically influence Se bioavailability and bioactivity to humans and animals. Se bioavailability is affected by foodstuff-matrix major composition and minor components. Foodstuffs processing and/or treatments could enhancement or decrease Se bioavailability. Experimental conditions such as the selection of healthy status of examined people (in in vivo humans approaches), the selection of animal model (in vivo animals approaches), or the selection of GI conditions (in in vitro tests) could determines the results. Thus, international standardized protocol for in vivo and in vitro approaches assessment is mandatory.

  4. The effect of consumption of selenium enriched rye/wheat sourdough bread on the body's selenium status.

    Science.gov (United States)

    Bryszewska, Malgorzata A; Ambroziak, Wojciech; Langford, Nicola J; Baxter, Malcolm J; Colyer, Alison; Lewis, D John

    2007-09-01

    The potential of selenium-enriched rye/wheat sourdough bread as a route for supplementing dietary selenium intakes is reported. In addition to their normal diets, 24 female volunteers (24 to 25 years old) were fed either selenium-enriched bread or non-enriched bread each day (68.02 and 0.84 microg selenium day(-1) respectively) for 4 weeks. The chemical form of the selenium in the bread had been characterised using HPLC-ICP-MS, which showed that 42% of the extractable selenium was present as selenomethionine. Plasma selenium levels and plasma platelet glutathione peroxidase (GPx1) activity were measured in the volunteers' blood over a 6-week period. A statistically significant difference (p = 0.001) was observed in the mean percentage change data, calculated from the plasma selenium level measurements for the enriched and control group, over the duration of the study. A comparable difference was not observed for the platelet GPx1 activity (p = 0.756), over the same period. Two weeks after cessation of the feeding stage, i.e., at t = 6 weeks, the mean percentage change value for the selenium plasma levels in the enriched group was still significantly elevated, suggesting that the absorbed selenium had been incorporated into the body's selenium reserves, and was then being slowly released back into the volunteers' blood.

  5. High-resolution imaging of selenium in kidneys: a localized selenium pool associated with glutathione peroxidase 3

    Energy Technology Data Exchange (ETDEWEB)

    Malinouski, M.; Kehr, S.; Finney, L.; Vogt, S.; Carlson, B.A.; Seravalli, J.; Jin, R.; Handy, D.E.; Park, T.J.; Loscalzo, J.; Hatfield, D.L.; Gladyshev, V.N. (Harvard-Med)

    2012-04-17

    Recent advances in quantitative methods and sensitive imaging techniques of trace elements provide opportunities to uncover and explain their biological roles. In particular, the distribution of selenium in tissues and cells under both physiological and pathological conditions remains unknown. In this work, we applied high-resolution synchrotron X-ray fluorescence microscopy (XFM) to map selenium distribution in mouse liver and kidney. Liver showed a uniform selenium distribution that was dependent on selenocysteine tRNA{sup [Ser]Sec} and dietary selenium. In contrast, kidney selenium had both uniformly distributed and highly localized components, the latter visualized as thin circular structures surrounding proximal tubules. Other parts of the kidney, such as glomeruli and distal tubules, only manifested the uniformly distributed selenium pattern that co-localized with sulfur. We found that proximal tubule selenium localized to the basement membrane. It was preserved in Selenoprotein P knockout mice, but was completely eliminated in glutathione peroxidase 3 (GPx3) knockout mice, indicating that this selenium represented GPx3. We further imaged kidneys of another model organism, the naked mole rat, which showed a diminished uniformly distributed selenium pool, but preserved the circular proximal tubule signal. We applied XFM to image selenium in mammalian tissues and identified a highly localized pool of this trace element at the basement membrane of kidneys that was associated with GPx3. XFM allowed us to define and explain the tissue topography of selenium in mammalian kidneys at submicron resolution.

  6. The Outcome of Selenium and Vitamin E Cancer Prevention Trial (SELECT) reveals the need for better understanding of selenium biology.

    Science.gov (United States)

    Hatfield, Dolph L; Gladyshev, Vadim N

    2009-02-01

    The recently completed Selenium and Vitamin E Cancer Prevention Trial (SELECT) was one of the largest human cancer prevention trials ever undertaken. Its purpose was to assess the role of selenium and vitamin E in prostate cancer prevention, but SELECT found no decline in prostate cancer. Comparison of this study to other clinical trials involving selenium and to the results of animal studies suggests that the source of the selenium supplement, L-selenomethionine, and the relatively high initial levels of selenium in the enrolled men may have contributed to this outcome. Further analysis of the clinical and animal data highlights the need for mechanistic studies to better understand selenium biology in order to target dietary selenium to appropriate subsets of the human population: those individuals most likely to benefit from this micronutrient.

  7. Electrocoagulation of colloidal biogenic selenium.

    Science.gov (United States)

    Staicu, Lucian C; van Hullebusch, Eric D; Lens, Piet N L; Pilon-Smits, Elizabeth A H; Oturan, Mehmet A

    2015-02-01

    Colloidal elemental selenium (Se(0)) adversely affects membrane separation processes and aquatic ecosystems. As a solution to this problem, we investigated for the first time the removal potential of Se(0) by electrocoagulation process. Colloidal Se(0) was produced by a strain of Pseudomonas fluorescens and showed limited gravitational settling. Therefore, iron (Fe) and aluminum (Al) sacrificial electrodes were used in a batch reactor under galvanostatic conditions. The best Se(0) turbidity removal (97 %) was achieved using iron electrodes at 200 mA. Aluminum electrodes removed 96 % of colloidal Se(0) only at a higher current intensity (300 mA). At the best Se(0) removal efficiency, electrocoagulation using Fe electrode removed 93 % of the Se concentration, whereas with Al electrodes the Se removal efficiency reached only 54 %. Due to the less compact nature of the Al flocs, the Se-Al sediment was three times more voluminous than the Se-Fe sediment. The toxicity characteristic leaching procedure (TCLP) test showed that the Fe-Se sediment released Se below the regulatory level (1 mg L(-1)), whereas the Se concentration leached from the Al-Se sediment exceeded the limit by about 20 times. This might be related to the mineralogical nature of the sediments. Electron scanning micrographs showed Fe-Se sediments with a reticular structure, whereas the Al-Se sediments lacked an organized structure. Overall, the results obtained showed that the use of Fe electrodes as soluble anode in electrocoagulation constitutes a better option than Al electrodes for the electrochemical sedimentation of colloidal Se(0).

  8. The Relationship between Selenium and T3 in Selenium Supplemented and Nonsupplemented Ewes and Their Lambs

    Directory of Open Access Journals (Sweden)

    Abd Elghany Hefnawy

    2014-01-01

    Full Text Available Twenty pregnant ewes were selected and classified into two groups. The first group received subcutaneous selenium supplementation (0.1 mg of sodium selenite/kg BW at the 8th and 5th weeks before birth and 1st week after birth while the other was control group without selenium injection. Maternal plasma and serum samples were collected weekly from the 8th week before birth until the 8th week after birth and milk samples were taken from ewes weekly, while plasma and serum samples were collected at 48 hours, 1st, 2nd, 3rd, 5th, and 8th weeks after birth from the newborn lambs. Results demonstrated significant positive relationship between maternal plasma selenium and serum T3 in supplemented and control ewes (r=0.69 to 0.72, P<0.05. There was significant (P<0.001 increase in T3 in supplemented ewes and their lambs until the 8th week after birth. There was positive relationship between milk, selenium concentration, and serum T3 in the newborn lambs of the supplemented group (r=0.84, P<0.01, while the relationship was negative in the control one (r=-0.89, P<0.01. Muscular and thyroid pathological changes were independent of selenium supplementation. Selenium supplementation was important for maintaining T3 in ewes and newborn lambs until the 8th week after birth.

  9. Fundamentals of amorphous solids structure and properties

    CERN Document Server

    Stachurski, Zbigniew H

    2014-01-01

    Long awaited, this textbook fills the gap for convincing concepts to describe amorphous solids. Adopting a unique approach, the author develops a framework that lays the foundations for a theory of amorphousness. He unravels the scientific mysteries surrounding the topic, replacing rather vague notions of amorphous materials as disordered crystalline solids with the well-founded concept of ideal amorphous solids. A classification of amorphous materials into inorganic glasses, organic glasses, glassy metallic alloys, and thin films sets the scene for the development of the model of ideal amorph

  10. Nanostructures having crystalline and amorphous phases

    Science.gov (United States)

    Mao, Samuel S; Chen, Xiaobo

    2015-04-28

    The present invention includes a nanostructure, a method of making thereof, and a method of photocatalysis. In one embodiment, the nanostructure includes a crystalline phase and an amorphous phase in contact with the crystalline phase. Each of the crystalline and amorphous phases has at least one dimension on a nanometer scale. In another embodiment, the nanostructure includes a nanoparticle comprising a crystalline phase and an amorphous phase. The amorphous phase is in a selected amount. In another embodiment, the nanostructure includes crystalline titanium dioxide and amorphous titanium dioxide in contact with the crystalline titanium dioxide. Each of the crystalline and amorphous titanium dioxide has at least one dimension on a nanometer scale.

  11. Amorphization of Crystalline Water Ice

    CERN Document Server

    Zheng, Weijun; Kaiser, Ralf I

    2008-01-01

    We conducted a systematic experimental study to investigate the amorphization of crystalline ice by irradiation in the 10-50 K temperature range with 5 keV electrons at a dose of ~140 eV per molecule. We found that crystalline water ice can be converted partially to amorphous ice by electron irradiation. Our experiments showed that some of the 1.65-micrometer band survived the irradiation, to a degree that depends on the temperature, demonstrating that there is a balance between thermal recrystallization and irradiation-induced amorphization, with thermal recrystallizaton dominant at higher temperatures. At 50 K, recrystallization due to thermal effects is strong, and most of the crystalline ice survived. Temperatures of most known objects in the solar system, including Jovian satellites, Saturnian satellites, and Kuiper belt objects, are equal to or above 50 K, this might explain why water ice detected on those objects is mostly crystalline.

  12. Status of selenium in cancer prevention

    Science.gov (United States)

    An abundance of data indicate that selenium (Se) can be antitumorigenic. Those data, mostly from controlled studies using animal tumor models and some from clinical studies in free-living people, indicate that treatment with Se in the absence of nutritional Se-deficiency, can reduce cancer risk. T...

  13. Selenium, glutathione peroxidase and other selenoproteins

    Energy Technology Data Exchange (ETDEWEB)

    Wilhelmsen, E.C.

    1983-01-01

    Selenium, as essential trace element, has long been associated with protein. The essentiality of selenium is partially understood as glutathione peroxidase contains an essential selenocysteine. Glutathione peroxidase has been purified from many tissues including rat liver. An estimated molecular weight of 105,000 was obtained for glutathione peroxidase by comparison to standards. A subunit size of 26,000 was obtained by SDS-gel electrophoresis. Glutathione peroxidase is not the only selenoprotein in the rat. In seven rat tissues examined, there were many different subunit sizes and change groups representing between 9 and 23 selenoproteins. Selenocysteine in glutathione peroxidase accounts for ca. 36% of the selenium in the rat. The mode of synthesis of glutathione peroxidase and the other selenoproteins is not understood. Glutathione peroxidase is strongly and reversibly inhibited by mercaptocarboxylic acids and other mercaptans, including some used as slow-acting drugs for the symtomatic treatment of rheumatoid arthritis. The mechanism and chemistry of this inhibition is discussed. This inhibition may provide a link between selenium and arthritis.

  14. Mercury and selenium content of Taiwanese seafood.

    Science.gov (United States)

    Fang, G C; Nam, D H; Basu, N

    2011-01-01

    Fish consumption is avid in Taiwan (and other Asian nations), but little is known about the mercury and selenium content in local seafood. This paper reports on total mercury, methylmercury and selenium levels from 14 commonly consumed seafood items obtained from Taichung, Taiwan. Mean total mercury concentrations varied nearly 100-fold across species. Fifty per cent of the marlins sampled and 35% of the sharks exceeded the 0.3 µg g(-1) US Environmental Protection Agency (USEPA) guideline. Methylmercury comprised a majority of the total mercury in all species. In all species studied there was a molar excess of selenium over mercury. The rank order of mean selenium-mercury molar ratios was red tilapia (166.8) > abura (87.9) > river prawn (82.4) > whiteleg shrimp (64.2) > butterfish (44.6) > milkfish (37.0) > tuna (15.6) > grouper (13.9) > ayu (13.4) > coral hind (13.0) > weever (11.8) > saury (9.0) > shark (7.8) > marlin (4.2).

  15. [Selenium and oxidative stress in cancer patients].

    Science.gov (United States)

    Gorozhanskaia, É G; Sviridova, S P; Dobrovol'skaia, M M; Zybrikhina, G N; Kashnia, Sh R

    2013-01-01

    In order to identify the features of violations of free-radical processes in blood serum of 94 untreated cancer patients with different localization of the tumor (cancer of the stomach, colon, breast, ovarian, hemoblastoses) were determined selenium levels and indicators of oxidative stress (sum of metabolites of nitrogen--NOx, the level of superoxide dismutase--Cu/ZnSOD and malondiialdehyde-MDA, and the activity of catalase). In addition, 40 patients with malignant liver disease and clinical signs of liver failure in the early postoperative period was carried out a comparative evaluation of the efficacy of selenium-containing drug "Selenaze" (sodium selenite pentahydrate). It was found that selenium levels in cancer patients by 25-30% below the norm of 110-120 mg/l at a rate of 73.0 +/- 2.6 mg/l. Low levels of NOx was detected in patients with all tumor localizations (22.1 +/- 1.1 microM, with normal range 28.4 +/- 0.9 microM). The exceptions were patients with extensive malignant process in the liver, in which the NOx levels were significantly higher than normal (p selenium levels by 10-12%, which was accompanied by a decrease in the content of SOD and NOx, and contributed to earlier recovery of detoxic and synthetic liver function. These findings point to an intensification of oxidative stress and metabolic disorders in the malignant process, which is the basis for metabolic correction.

  16. Selenium speciation in anaerobic granular sludge

    NARCIS (Netherlands)

    Lenz, M.; Gmerek, A.; Lens, P.N.L.

    2006-01-01

    Chromatographic (IC-CD, GC-FID) and spectroscopic (XRD) techniques that allow the specific determination of several selenium species present or formed during bioremediation processes of selenate contaminated drinking, ground, or wastewaters have been established. The developed techniques are shown t

  17. Selenium, selenoproteins and human health: a review.

    Science.gov (United States)

    Brown, K M; Arthur, J R

    2001-04-01

    Selenium is of fundamental importance to human health. It is an essential component of several major metabolic pathways, including thyroid hormone metabolism, antioxidant defence systems, and immune function. The decline in blood selenium concentration in the UK and other European Union countries has therefore several potential public health implications, particularly in relation to the chronic disease prevalence of the Western world such as cancer and cardiovascular disease. Ten years have elapsed since recommended dietary intakes of selenium were introduced on the basis of blood glutathione peroxidase activity. Since then 30 new selenoproteins have been identified, of which 15 have been purified to allow characterisation of their biological function. The long term health implications in relation to declining selenium intakes have not yet been thoroughly examined, yet the implicit importance of selenium to human health is recognised universally. Selenium is incorporated as selenocysteine at the active site of a wide range of selenoproteins. The four glutathione peroxidase enzymes (classical GPx1, gastrointestinal GPx2, plasma GPx3, phospholipid hydroperoxide GPx4)) which represent a major class of functionally important selenoproteins, were the first to be characterised. Thioredoxin reductase (TR) is a recently identified seleno-cysteine containing enzyme which catalyzes the NADPH dependent reduction of thioredoxin and therefore plays a regulatory role in its metabolic activity. Approximately 60% of Se in plasma is incorporated in selenoprotein P which contains 10 Se atoms per molecule as selenocysteine, and may serve as a transport protein for Se. However, selenoprotein-P is also expressed in many tissues which suggests that although it may facilitate whole body Se distribution, this may not be its sole function. A second major class of selenoproteins are the iodothyronine deiodinase enzymes which catalyse the 5'5-mono-deiodination of the prohormone thyroxine (T4

  18. Selenium and Thyroid Disease: From Pathophysiology to Treatment

    Directory of Open Access Journals (Sweden)

    Mara Ventura

    2017-01-01

    Full Text Available Introduction. Selenium is a micronutrient embedded in several proteins. In adults, the thyroid is the organ with the highest amount of selenium per gram of tissue. Selenium levels in the body depend on the characteristics of the population and its diet, geographic area, and soil composition. In the thyroid, selenium is required for the antioxidant function and for the metabolism of thyroid hormones. Methods. We performed a review of the literature on selenium’s role in thyroid function using PubMed/MEDLINE. Results. Regarding thyroid pathology, selenium intake has been particularly associated with autoimmune disorders. The literature suggests that selenium supplementation of patients with autoimmune thyroiditis is associated with a reduction in antithyroperoxidase antibody levels, improved thyroid ultrasound features, and improved quality of life. Selenium supplementation in Graves’ orbitopathy is associated with an improvement of quality of life and eye involvement, as well as delayed progression of ocular disorders. The organic form of selenium seems to be the preferable formulation for supplementation or treatment. Conclusion. Maintaining a physiological concentration of selenium is a prerequisite to prevent thyroid disease and preserve overall health. Supplementation with the organic form is more effective, and patients with autoimmune thyroiditis seem to have benefits in immunological mechanisms. Selenium supplementation proved to be clinically beneficial in patients with mild to moderate Graves’ orbitopathy.

  19. Selenium and the thyroid gland: more good news for clinicians.

    Science.gov (United States)

    Drutel, Anne; Archambeaud, Françoise; Caron, Philippe

    2013-02-01

    The thyroid is the organ with the highest selenium content per gram of tissue because it expresses specific selenoproteins. Since the discovery of myxoedematous cretinism and thyroid destruction following selenium repletion in iodine- and selenium-deficient children, data on links between thyroid metabolism and selenium have multiplied. Although very minor amounts of selenium appear sufficient for adequate activity of deiodinases, thus limiting the impact of its potential deficiency on synthesis of thyroid hormones, selenium status appears to have an impact on the development of thyroid pathologies. The value of selenium supplementation in autoimmune thyroid disorders has been emphasized. Most authors attribute the effect of supplementation on the immune system to the regulation of the production of reactive oxygen species and their metabolites. In patients with Hashimoto's disease and in pregnant women with anti-TPO antibodies, selenium supplementation decreases anti-thyroid antibody levels and improves the ultrasound structure of the thyroid gland. Although clinical applications still need to be defined for Hashimoto's disease, they are very interesting for pregnant women given that supplementation significantly decreases the percentage of postpartum thyroiditis and definitive hypothyroidism. In Graves' disease, selenium supplementation results in euthyroidism being achieved more rapidly and appears to have a beneficial effect on mild inflammatory orbitopathy. A risk of diabetes has been reported following long-term selenium supplementation, but few data are available on the side effects associated with such supplementation and further studies are required.

  20. Theory of Electronic Structures of Selenium and Tellurium with and without Impurities

    Science.gov (United States)

    Cho, Hwa-Suck; Scheicher, R. H.; Jeong, Junho; Das, T. P.; Paudyal, D. D.; Maharjan, N. B.; Mishra, D. R.; Byahut, S. P.

    2003-03-01

    As part of our program to understand at an electronic level the mechanism for influence of impurity ions on glass transition temperatures in chalcogen glasses we are carrying out electronic structure investigations of pure Se and Te and with Te and Se impurities respectively, to examine how well one can explain available nuclear quadrupole interaction (NQI) tensors for ^77Se and ^125Te nuclei in the latter four systems(See for instance, P. Boolchand et al., Phys. Rev. Lett. 30, 1292 (1973); Solid State Commun. 13, 1619 (1973).) and thus obtain an assessment of the accuracy of the electronic structures of these systems. Our results on the chains of selenium and tellurium show good agreement with NQI data for the pure and impurity systems. Investigations are in progress on Se and Te rings that occur in amorphous systems.

  1. DETERMINING OPTICAL CONSTANTS OF SELENIUM THIN FILMS USING THE ENVELOPE METHOD

    Directory of Open Access Journals (Sweden)

    Nehad M. Tashtoush

    2013-01-01

    Full Text Available Two Selenium thin films were deposited on glass substrates using thermal evaporation technique. The optical constants (refractive index, absorption coefficient and extinction coefficient and energy gap were calculated using the Transmittance (T spectrums of the films in the spectral range of 500-900 nm. The envelope method was used to determine optical constants. The calculated refractive index was found to be in the range of 2.60 to 2.85 and the Energy gap (Eg was found to be 1.8 eV which are in agreement with other studies made using other procedures. The films were found to be amorphous according to the results obtained by XRD technique. This method can be used to have a good results for many tranparent thin films with more mathematical tools.

  2. Enrichment of the African catfish Clarias gariepinus (Burchell) with functional selenium originating from garlic: effect of enrichment period and depuration on total selenium level and sensory properties

    NARCIS (Netherlands)

    Schram, E.; Schelvis-Smit, A.A.M.; Heul, van der J.W.; Luten, J.B.

    2010-01-01

    We wanted to optimize the procedure for the selenium enrichment of farmed African catfish, using garlic as dietary selenium source. In the first experiment we established the relation between the length of the selenium enrichment period and the resulting total selenium level in the fillet of the fis

  3. Amorphous titanium-oxide supercapacitors

    Science.gov (United States)

    Fukuhara, Mikio; Kuroda, Tomoyuki; Hasegawa, Fumihiko

    2016-10-01

    The electric capacitance of an amorphous TiO2-x surface increases proportionally to the negative sixth power of the convex diameter d. This occurs because of the van der Waals attraction on the amorphous surface of up to 7 mF/cm2, accompanied by extreme enhanced electron trapping resulting from both the quantum-size effect and an offset effect from positive charges at oxygen-vacancy sites. Here we show that a supercapacitor, constructed with a distributed constant-equipment circuit of large resistance and small capacitance on the amorphous TiO2-x surface, illuminated a red LED for 37 ms after it was charged with 1 mA at 10 V. The fabricated device showed no dielectric breakdown up to 1,100 V. Based on this approach, further advances in the development of amorphous titanium-dioxide supercapacitors might be attained by integrating oxide ribbons with a micro-electro mechanical system.

  4. Selenium Recycling in the United States in 2004

    Science.gov (United States)

    George, Micheal W.; Wagner, Lorie A.

    2009-01-01

    The vast majority of selenium consumption in the United States is in dissipative uses, such as alloys, animal feeds, fertilizers, glass decolorizer, and pigments. The nondissipative use as a photoreceptor for xerographic copiers is declining. As a result of a lack of a substantial supply of selenium-containing scrap, there are no longer selenium recycling facilities in the United States. Selenium-containing materials collected for recycling, primarily selenium-containing photocopier drums, are exported for processing in other countries. Of the estimated 350 metric tons (t) of selenium products that went to the U.S. market in 2004, an estimated 300 t went to dissipative uses. An estimated 4 t was recovered from old scrap and exported for recycling.

  5. Production of selenium-enriched milk and dairy products

    Directory of Open Access Journals (Sweden)

    Csapó J.

    2015-01-01

    Full Text Available Until the middle of the last century, selenium was considered to be toxic, but recently it turned out to be a micronutrient with important physiological effects, whose lack impedes the functioning of several enzymes, while in the case of a prolonged deficiency, disease processes can also occur in the body. Hungary belongs to the selenium-deficient regions in Europe; therefore, our aim was to contribute to the improvement of selenium supply of the population through increasing the selenium content of milk and dairy products. A daily supplementation of 1-6 mg organic selenium to the feed of dairy cows increases the selenium content of milk from the value of 18 μg/kg to 94 μg/kg in 8 weeks, decreasing again to the initial value in 6 weeks after stopping the supplementation.

  6. Speciation of organic and inorganic selenium in selenium-enriched rice by graphite furnace atomic absorption spectrometry after cloud point extraction.

    Science.gov (United States)

    Sun, Mei; Liu, Guijian; Wu, Qianghua

    2013-11-01

    A new method was developed for the determination of organic and inorganic selenium in selenium-enriched rice by graphite furnace atomic absorption spectrometry detection after cloud point extraction. Effective separation of organic and inorganic selenium in selenium-enriched rice was achieved by sequentially extracting with water and cyclohexane. Under the optimised conditions, the limit of detection (LOD) was 0.08 μg L(-1), the relative standard deviation (RSD) was 2.1% (c=10.0 μg L(-1), n=11), and the enrichment factor for selenium was 82. Recoveries of inorganic selenium in the selenium-enriched rice samples were between 90.3% and 106.0%. The proposed method was successfully applied for the determination of organic and inorganic selenium as well as total selenium in selenium-enriched rice.

  7. [Studies on the assimilation of inorganic selenium by yeast].

    Science.gov (United States)

    Xie, L; Ouyang, Z; Xie, X

    1990-02-01

    In the process of assimilation of inorganic selenium by yeast to the organic-selenium, some rules on the relation of the kinds of culture medium, concentration of sodium selenite and methionine to the total selenium and selenomethionine content in the yeast formed have been found; and a new, accurate procedure--modified acid hydrolysis-ion exchange chromatography for determining the content of seleno-amino acid in biological materials has been established.

  8. Test Automation Selenium WebDriver using TestNG

    OpenAIRE

    Bindal, Purnima; Gupta, Sonika

    2014-01-01

    Test automation tools (softwares) are used to control the execution of tests (Application Under Test) and then comparing actual outcomes to the predicted outcomes. Examples of Test Automation tools are HP Quick Test Professional, Selenium, Test Complete, SOAP UI etc. Selenium is a suite of tools for cross-platform automated testing of web applications. It runs on many browsers and operating systems and can be controlled by many programming languages and testing frameworks. Selenium W...

  9. Selenium Poisoning of Wildlife and Western Agriculture: Cause and Effect

    Energy Technology Data Exchange (ETDEWEB)

    Korte, N.E.

    2000-02-01

    This project examined the hypothesis that selenium contamination is not the principal cause of the decline of endemic fish species in the Upper Colorado Basin. Activities employed to test this hypothesis included a reconnaissance of locations altered by recent road construction, a re-interpretation of available literature regarding selenium toxicity, and the interpretation of unpublished data obtained from the Upper Colorado Basin Fish Recovery Program. The project demonstrates that most of the evidence implicating selenium is circumstantial.

  10. Immunomodulatory effect of selenosemicarbazides and selenium inorganic compounds, distribution in organs after selenium supplementation.

    Science.gov (United States)

    Musik, I; Koziol-Montewka, M; Toś-Luty, S; Pasternak, K; Latuszyńska, J; Tokarska, M; Kielczykowska, M

    1999-12-01

    Antioxidant properties of selenium producing a protective barrier against free radicals play an important role in numerous metabolic and immunologic processes associated with oxidation-reduction reactions which take place during intracellular digestion of phagocyted bacteria. The aim of our study was to examine the properties of an organic compound of selenium, 4-(o-tolilo)-selenosemicarbazide of p-chlorobenzoic acid in terms of its retention in organs, effect on erythropoesis and phagocytic abilities of neutrophiles as well as antioxidant properties in neutrophiles tested with NBT test. This compound as well as inorganic sodium selenate was given to Swiss mice at the dose of 10(-3) g Se/kg for the period of 10 days. The concentrations of selenium in livers of mice treated with sodium selenate and selenosemicarbazide were found to be higher than in controls (18.7 micrograms lg-1 and 23.2 micrograms lg-1 vs. 12 micrograms lg-1, respectively). Analysis of blood cells count has shown a significant decrease in neutrophile levels in both groups treated with selenium. The influence of selenium compounds on phagocytosis and especially NBT test has been determined (3.8% of positive cells in the controls vs. 2.2% and 0.9% in the groups treated with sodium selenate and selenosemicarbazide, respectively). Our preliminary investigations suggest that selenosemicarbazides are biologically active compounds and can modify neutrophile functions.

  11. Distribution of Selenium in Corn and Its Relationship With Soil Selenium in Yutangba Mini—Landscape

    Institute of Scientific and Technical Information of China (English)

    朱建明; 毛大均; 等

    2000-01-01

    Within the range of 0.01 km2 mini-landscape in Yutangba,Enshi,Hubei Province,the content of Se in corn is very high,The average Se contents in root,stem,leaf and seed of corn were estimated to be 4.36±3.27mg.kg,3.08±2.24mg/kg,9.74±7.62mg/kg,and 8.07±5.02mg/kg,respectively.The research results show that there is a significantly poistive correlation between corn selenium and soil selenium,and thus according to the distribtuion of Se in corn.Three subregions can be divided in Yutangba,The content of selenium in corn is controlled by that of soil.A little variation in selenium content in soil will lead to a considerable corresponding variation in corn.So it is deduced that the organs that contain relatively high Se in plants may be used as a sensitive selenium indicator of Se levels in the environment.

  12. Randomised clinical trial of parenteral selenium supplementation in preterm infants.

    OpenAIRE

    Daniels, L; Gibson, R.; Simmer, K.

    1996-01-01

    AIM: To determine whether selenium supplementation of parenteral nutrition with 3 micrograms/kg/day of selenious acid is safe and effective in improving the selenium status of preterm infants. METHODS: Thirty eight preterm infants with mean (SEM) birthweight of 1171 (38) g and gestational age 29 (0.3) weeks were randomly allocated to a non-supplemented (PN-selenium, n = 19) or supplemented (PN+selenium, n = 19) group. The study began at 2.8 (0.2) (range 1-5) days of age. Term breastfed (n = 2...

  13. Ecological Importance of Insects in Selenium Biogenic Cycling

    Directory of Open Access Journals (Sweden)

    Nadezhda Golubkina

    2014-01-01

    Full Text Available Selenium is an essential trace element for animal and human beings. Despite the importance of insects in most ecosystems and their significant contribution to the biological cycling of trace elements due to high abundance, population productivity, and diverse ecosystem functions, surprisingly little information is available on selenium bioaccumulation by these arthropods. This review considers selenium essentiality and toxicity to insects as well as insects’ contribution to selenium trophic transfer through the food chains. Data on Se accumulation by insects of the Dniester River Valley with no anthropogenic Se loading reveal typically low Se content in necrophagous insects compared to predators and herbivores and seasonal variations in Se accumulation.

  14. Selenium nanomaterials: applications in electronics, catalysis and sensors.

    Science.gov (United States)

    Chaudhary, Savita; Mehta, S K

    2014-02-01

    This review provides insights into the synthesis, functionalization, and applications of selenium nanoparticles in electronics, optics, catalysis and sensors. The variation of physicochemical properties such as particle size, surface area, and shape of the selenium nanoparticles and the effect of experimental conditions has also been discussed. An overview has also been provided on the fundamental electrical and optical properties of selenium nanomaterials as well as their utilization in different research fields. The work presents an insight on selenium nanoparticles with interesting properties and their future applications.

  15. [Selenium toxicity in domestic animals].

    Science.gov (United States)

    Mihajlović, M

    1992-01-01

    The earliest written report of selenium poisoning is thought to be the description by Marco Polo of a necrotic hoof disease of horses that occurred in China in 13. century. However recognition of Se as toxic principle come in the early 1930s. Severity of Se poisoning depends on chemical forms of the element, species of animals and routes of administration. The soluble Se salts (Na2SeO3 and Na2SeO4) appear to be among the more toxic compounds; the Se inherent in grains and selenoamino acids (selenomethionine and selenocystine) appear to have relative moderate toxicity; the poorly soluble forms (e.g., elemental Se, Na2Se, SeS2 and diphenyl selenide) are among the least toxic of the Se compounds. In general, toxicity of Se compounds are substantially less when they are administered orally than when they are given parenterally. Rosenfeld and Beath described three clinical types of Se intoxication: acute selenosis, subacute selenosis (i.e., blind staggers type), and chronic selenosis (i.e., alkali disease type). Acute poisoning occurs when high Se content plants are consumed in large quantities within short period. Accidental acute poisoning occurs as consequence of errors in formulation of a Se supplemented diet. The most characteristic sign of acute selenosis is garlic breath due to the pulmonary excretion of volatile Se metabolites. Other signs include lethargy, excessive salivation, vomiting, dyspnea, muscle tremors and respiratory distress. Pathological findings are: congestion of the liver and kidney, fatty degeneration and focal necrosis of the liver, endocarditis and myocarditis. Subacute selenosis ("blind staggers") occurs as a consequence of exposure to large doses of Se over a longer period of time and manifests with neurological signs (e.g., blindness, ataxia, disorientation) and respiratory distress. This form of selenosis is most frequently observed in grazing animals that have consumed Se-accumulated plants. Chronic selenosis ("alkali disease") comes

  16. Evaluation of the nutritional quality of veal supplemented with organic selenium and its effect on selenium status of people

    Directory of Open Access Journals (Sweden)

    Klára Vavrišínová

    2016-05-01

    Full Text Available In the first stage of our research we found out a higher content of selenium in the meat of calves of experimental group (with added the organic form of selenium to the feed mixture compared to control group (fed without organic form of selenium. In the second stage of our research we focused on monitoring the impact of selenium enriched veal meat and on selenium concentration in blood serum and the selected biochemical parameters of lipid spectrum of the experimental group of volunteers. Ten people who were participating in the research were at the age range between 29 - 56 years. All the volunteers consumed veal meat enriched with organic selenium for 4 weeks. Before starting the experiment we took venous blood of the volunteers and this blood was considered as a control sample of selenium in blood serum of the experimental group. Selenium concentration in blood serum of the examined group was determined by an average of 58.31 ±5.36 mg.L.-1 and none of them reached the optimal level of selenium. Consequently, we carried out the additional blood sampling after 2 and 4 weeks of the consumption of veal meat. There was registered a slight increasing of selenium status, whereas after the finishing the consumption, we determined the average selenium concentration in blood serum of the experimental group 60.73 ±4.05 mg.L-1. The evaluation of lipid profile of the experimental group showed (after input blood sampling higher values of total cholesterol level and lower levels of HDL cholesterol. This fact shows the higher risk of starting the cardiovascular diseases. Reported research results didn't show statistically significant changes of blood lipid spectrum of the experimental group. We concluded that the consumption of supplemented veal meat can positively affect the level of selenium in our body and thereby increase it can increase the protective effect against the influence of free radicals.

  17. Flexible amorphous metal films with high stability

    Science.gov (United States)

    Liu, M.; Cao, C. R.; Lu, Y. M.; Wang, W. H.; Bai, H. Y.

    2017-01-01

    We report the formation of amorphous Cu50Zr50 films with a large-area of more than 100 cm2. The films were fabricated by ion beam assisted deposition with a slow deposition rate at moderate temperature. The amorphous films have markedly enhanced thermal stability, excellent flexibility, and high reflectivity with atomic level smoothness. The multifunctional properties of the amorphous films are favorites in the promising applications of smart skin or wearable devices. The method of preparing highly stable amorphous metal films by tuning the deposition rate instead of deposition temperature could pave a way for exploring amorphous metal films with unique properties.

  18. Selenium supplementation for critically ill adults

    DEFF Research Database (Denmark)

    Allingstrup, Mikkel; Afshari, Arash

    2015-01-01

    BACKGROUND: Selenium is a trace mineral essential to health and has an important role in immunity, defence against tissue damage and thyroid function. Improving selenium status could help protect against overwhelming tissue damage and infection in critically ill adults. This Cochrane review......, to May 20, 2014), EMBASE (Ovid SP, to May 20, 2014), CAB, BIOSIS and CINAHL. We handsearched the reference lists of the newest reviews and cross-checked with our search in MEDLINE. We contacted the main authors of included studies to request any missed, unreported or ongoing studies. The latest search...... in order to retrieve relevant and missing data. DATA COLLECTION AND ANALYSIS: Two review authors independently extracted data and we resolved any disagreements by discussion. Our primary outcome measure was all-cause mortality. We performed several subgroup and sensitivity analyses to assess the effects...

  19. Selenoprotein P Is the Major Selenium Transport Protein in Mouse Milk

    Science.gov (United States)

    Hill, Kristina E.; Motley, Amy K.; Winfrey, Virginia P.; Burk, Raymond F.

    2014-01-01

    Selenium is transferred from the mouse dam to its neonate via milk. Milk contains selenium in selenoprotein form as selenoprotein P (Sepp1) and glutathione peroxidase-3 (Gpx3) as well as in non-specific protein form as selenomethionine. Selenium is also present in milk in uncharacterized small-molecule form. We eliminated selenomethionine from the mice in these experiments by feeding a diet that contained sodium selenite as the source of selenium. Selenium-replete dams with deletion of Sepp1 or Gpx3 were studied to assess the effects of these genes on selenium transfer to the neonate. Sepp1 knockout caused a drop in milk selenium to 27% of the value in wild-type milk and a drop in selenium acquisition by the neonates to 35%. In addition to decreasing milk selenium by eliminating Sepp1, deletion of Sepp1 causes a decline in whole-body selenium, which likely also contributes to the decreased transfer of selenium to the neonate. Deletion of Gpx3 did not decrease milk selenium content or neonate selenium acquisition by measurable amounts. Thus, when the dam is fed selenium-adequate diet (0.25 mg selenium/kg diet), milk Sepp1 transfers a large amount of selenium to neonates but the transfer of selenium by Gpx3 is below detection by our methods. PMID:25068390

  20. Selenoprotein P is the major selenium transport protein in mouse milk.

    Directory of Open Access Journals (Sweden)

    Kristina E Hill

    Full Text Available Selenium is transferred from the mouse dam to its neonate via milk. Milk contains selenium in selenoprotein form as selenoprotein P (Sepp1 and glutathione peroxidase-3 (Gpx3 as well as in non-specific protein form as selenomethionine. Selenium is also present in milk in uncharacterized small-molecule form. We eliminated selenomethionine from the mice in these experiments by feeding a diet that contained sodium selenite as the source of selenium. Selenium-replete dams with deletion of Sepp1 or Gpx3 were studied to assess the effects of these genes on selenium transfer to the neonate. Sepp1 knockout caused a drop in milk selenium to 27% of the value in wild-type milk and a drop in selenium acquisition by the neonates to 35%. In addition to decreasing milk selenium by eliminating Sepp1, deletion of Sepp1 causes a decline in whole-body selenium, which likely also contributes to the decreased transfer of selenium to the neonate. Deletion of Gpx3 did not decrease milk selenium content or neonate selenium acquisition by measurable amounts. Thus, when the dam is fed selenium-adequate diet (0.25 mg selenium/kg diet, milk Sepp1 transfers a large amount of selenium to neonates but the transfer of selenium by Gpx3 is below detection by our methods.

  1. Selenium uptake and assessment of the biochemical changes in Arthrospira (Spirulina) platensis biomass during the synthesis of selenium nanoparticles.

    Science.gov (United States)

    Zinicovscaia, I; Chiriac, T; Cepoi, L; Rudi, L; Culicov, O; Frontasyeva, M; Rudic, V

    2017-01-01

    The process of selenium uptake by biomass of the cyanobacterium Arthrospira (Spirulina) platensis was investigated by neutron activation analysis at different selenium concentrations in solution and at different contact times. Experimental data showed good fit with the Freundlich adsorption isotherm model, with a regression coefficient value of 0.99. In terms of absorption dependence on time, the maximal selenium content was adsorbed in the first 5 min of interaction without significant further changes. It was also found that A. platensis biomass forms spherical selenium nanoparticles. Biochemical analysis was used to assess the changes in the main components of spirulina biomass (proteins, lipids, carbohydrates, and phycobilin) during nanoparticle formation.

  2. Improvement of Selenium Status of Pasture Crops

    DEFF Research Database (Denmark)

    Nielsen, Gunnar Gissel

    1984-01-01

    Selenium was applied to pasture crops in a field experiment (1) by foliar application of 10 g Se/ha as selenite in the spring, (2) or by 5 g Se/ha in the spring plus 5 g in early August, (3) as selenite-enriched calcium ammonium nitrate (CAN) at 4 g Se/ha after each cut, and (4) as 4 g Se after...

  3. The selenium content of edible mushrooms in Finland.

    Science.gov (United States)

    Piepponen, S; Liukkonen-Lilja, H; Kuusi, T

    1983-01-01

    In this investigation the selenium contents of 142 mushroom samples were determined. The majority of the samples were wild Finnish mushroom species generally used for human consumption. The selenium contents of some cultivated mushrooms were also determined. In all, the material analyzed consisted of 38 different mushroom species. Selenium concentrations were assayed after modified wet and dry ashing, by atomic-absorption spectrometry using the hydride technique and the standard-addition procedure. The reliability of the method was tested with certified standard reference materials. The results of analysis obtained indicate that selenium contents vary considerably between different mushroom species. Of the species investigated, by far the highest selenium contents were found in Boletus edulis (mean 17 mg/kg dry weight). Other mushrooms having considerable selenium contents included Macrolepiota (5.0 mg/kg), wild Agaricus spp. (2.7 mg/kg), Gasteromycetes (1.9 mg/kg), Lactarius torminosus (1.9 mg/kg) and Marasmius oreades (1.6 mg/kg). The contents in these mushrooms are sufficient to provide an amount of selenium that is nutritionally significant in relation to the total daily intake of selenium of the Finnish population. Other edible mushrooms generally used in Finnland, e.g. species belonging to Cantharellaceae, Russula, Boletaceae (other than B. edulis) and Lactarius (other than L. torminosus) contained only small amounts of selenium. The importance of these mushrooms as a source of selenium is therefore marginal. The selenium content of Lactarius torminosus decreased by an average of 32% during the blanching necessary before consumption of these mushrooms.

  4. Cytotoxicity of selenium nanoparticles in rat dermal fibroblasts

    Directory of Open Access Journals (Sweden)

    Ramos JF

    2012-07-01

    Full Text Available Joseph F Ramos,1 Thomas J Webster21School of Engineering, Center of Biomedical Engineering, 2School of Engineering and Department of Orthopedics, Brown University, Providence, RI, USABackground: Ventilator-associated pneumonia is a deadly nosocomial infection caused by contaminated endotracheal tubes. It has been shown that polyvinyl chloride (PVC, the endotracheal tube substrate coated with elemental selenium nanoparticles reduces bacterial adherence and proliferation on PVC by over 99%. However, it is not known if selenium nanoparticles elicit a cytotoxic effect in vitro. The purpose of this study was to investigate the cytotoxic effects of PVC coated with selenium nanoparticles on fibroblasts, which are mammalian cells central to endotracheal tube intubation.Methods: Different concentrations of selenium nanoparticles were precipitated onto the PVC surface by reduction of selenium salts using glutathione. Characterization of PVC coated with selenium nanoparticles was done by scanning electron microscopy, energy dispersive x-ray, and contact angle measurements. For the cytotoxicity experiments, fibroblasts were seeded at a density of 5000 cm2 onto PVC coated with three different concentrations of selenium nanoparticles (high, medium, low and incubated for 4 hours (adhesion as well as for 24 hours and 72 hours (proliferation. The half-maximal inhibitory concentration (IC50 value was determined after 72 hours using an ultrahigh concentration. MTT assays were used to assess cell viability at the indicated time points.Results: The three concentrations of selenium nanoparticles did not elicit a cytotoxic effect after 72 hours (P < 0.01, n = 3. It was found that the IC50 value was at the ultrahigh concentration of selenium nanoparticles. The nanoparticulate elemental selenium concentration previously shown to decrease the function of bacteria was shown not to cause a cytotoxic effect on fibroblasts in vitro.Conclusion: These findings demonstrate

  5. Amorphous metal based nanoelectromechanical switch

    KAUST Repository

    Mayet, Abdulilah M.

    2013-04-01

    Nanoelectromechanical (NEM) switch is an interesting ultra-low power option which can operate in the harsh environment and can be a complementary element in complex digital circuitry. Although significant advancement is happening in this field, report on ultra-low voltage (pull-in) switch which offers high switching speed and area efficiency is yet to be made. One key challenge to achieve such characteristics is to fabricate nano-scale switches with amorphous metal so the shape and dimensional integrity are maintained to achieve the desired performance. Therefore, we report a tungsten alloy based amorphous metal with fabrication process development of laterally actuated dual gated NEM switches with 100 nm width and 200 nm air-gap to result in <5 volts of actuation voltage (Vpull-in). © 2013 IEEE.

  6. Mercury and selenium in wild and experimental seals

    NARCIS (Netherlands)

    Ven, van de W.S.M.; Koeman, J.H.; Svenson, A.

    1979-01-01

    This paper describes the tissue distribution of inorganic mercury, organic mercury selenium in Dutch and British seals as well as in seals which were dosed with methylmercury under experimental conditions. In the experimental animals, a time-related increase of both mercury and selenium was found in

  7. Selenium enrichment pattern in flowering Chinese cabbage, cabbage and asparagus

    NARCIS (Netherlands)

    Mo, H.Z.; Yang Zhu, Yang; Zhang, M.

    2006-01-01

    CONCLUSIONS - Within a certain range, selenium accumulation in three studied vegetables was lineally correlated with spraying concentration. However, a too high concentration caused the reduction of vegetable output and damage in quality. - Twice spraying with lower concentration of selenium was a b

  8. Enrichment of African catfish with functional selenium originating from garlic

    NARCIS (Netherlands)

    Schram, E.; Pedrero, Z.; Camara, C.; Heul, van der J.W.; Luten, J.B.

    2008-01-01

    We wanted to create functional seafood with high concentrations of organic selenium (seleno-methyl-selenocysteine and ¿-glutamyl-seleno-methyl-selenocysteine) with anti-carcinogenic properties for human consumers. Garlic containing high concentrations of these organic selenium compounds was used as

  9. Dietary Selenium and Prostate Cancer Prevention: A Brief Review

    Directory of Open Access Journals (Sweden)

    Surasi VADHANAVIKIT

    2004-01-01

    Full Text Available Evidence suggests that the trace nutrient selenium may reduce the risk of prostate cancer. There is, however, a need to prove that intake of high but not toxic levels of selenium can prevent the disease in the general population, and to conduct further relevant study.

  10. 21 CFR 522.2100 - Selenium, vitamin E injection.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Selenium, vitamin E injection. 522.2100 Section... § 522.2100 Selenium, vitamin E injection. (a)(1) Specifications. The drug is an emulsion containing in... of vitamin E (68 I.U.) (as d-alpha tocopheryl acetate). (2) Sponsor. See No. 000061 in §...

  11. Effect of trichlorfon on selenium distribution in rabbits.

    Science.gov (United States)

    Kossakowski, S; Dziura, A

    1987-01-01

    The investigations were performed on 94 rabbits intoxicated with trichlorfon which were untreated or treated. The intoxicated rabbits were given per os Na75SeO3. Selenium distribution in different organs and tissues was examined radiometrically. In intoxicated untreated rabbits and in those at the beginning of treatment decreased selenium level was found.

  12. A global perspective of selenium deficiency and toxicity

    Science.gov (United States)

    Selenium is an essential nutrient that has a relatively narrow margin between ingested amounts that cause deficiency and toxicosis. Both selenium deficiency and toxicosis occur in several regions in many countries throughout the world and result in substantial losses to the livestock industry. Sel...

  13. Colloidal Photoluminescent Amorphous Porous Silicon, Methods Of Making Colloidal Photoluminescent Amorphous Porous Silicon, And Methods Of Using Colloidal Photoluminescent Amorphous Porous Silicon

    KAUST Repository

    Chaieb, Sahraoui

    2015-04-09

    Embodiments of the present disclosure provide for a colloidal photoluminescent amorphous porous silicon particle suspension, methods of making a colloidal photoluminescent amorphous porous silicon particle suspension, methods of using a colloidal photoluminescent amorphous porous silicon particle suspension, and the like.

  14. Serum selenium and ceruloplasmin in nigerians with peripartum cardiomyopathy.

    Science.gov (United States)

    Karaye, Kamilu M; Yahaya, Isah A; Lindmark, Krister; Henein, Michael Y

    2015-04-07

    The study aimed to determine if selenium deficiency, serum ceruloplasmin and traditional birth practices are risk factors for peripartum cardiomyopathy (PPCM), in Kano, Nigeria. This is a case-control study carried out in three hospitals, and PPCM patients were followed up for six months. Critically low serum selenium concentration was defined as 0.05). Logistic regression showed that rural residency significantly increased the odds for serum selenium <70 µg/L by 2.773-fold (p = 0.037). Baseline serum levels of selenium and ceruloplasmin were not associated with six-month mortality. This study has shown that selenium deficiency is a risk factor for PPCM in Kano, Nigeria, and is related to rural residency. However, serum ceruloplasmin, customary birth practices and some other characteristics were not associated with PPCM in the study area.

  15. Genome-wide association study of serum selenium concentrations

    DEFF Research Database (Denmark)

    Gong, Jian; Hsu, Li; Harrison, Tabitha

    2013-01-01

    Selenium is an essential trace element and circulating selenium concentrations have been associated with a wide range of diseases. Candidate gene studies suggest that circulating selenium concentrations may be impacted by genetic variation; however, no study has comprehensively investigated...... this hypothesis. Therefore, we conducted a two-stage genome-wide association study to identify genetic variants associated with serum selenium concentrations in 1203 European descents from two cohorts: the Prostate, Lung, Colorectal, and Ovarian (PLCO) Cancer Screening and the Women’s Health Initiative (WHI). We...... tested association between 2,474,333 single nucleotide polymorphisms (SNPs) and serum selenium concentrations using linear regression models. In the first stage (PLCO) 41 SNPs clustered in 15 regions had p

  16. Risks and benefits in agricultural uses of selenium.

    Science.gov (United States)

    Oldfield, J E

    1992-10-01

    Selenium deficiency in soils, and subsequently in crops that are grown on them, has been charted in various parts of the world. Use of carefully regulated amounts of supplemental selenium in such areas has been effective in improving productive performance of domestic food-producing animals, and some 30 years' experience has now been gained with various supplementation practices. Coincidentaliy, there have been instances reported of situations where selenium toxicity has resulted from a combination of naturally-high environmental levels, enhanced by agricultural, environmental and industrial practices, and questions have been raised as to whether continued animal supplementation may contribute to selenium toxicity. This paper examines some of the various factors involved and concludes that presently-established animal supplementation uses of selenium are small compared with other sources of the element and that they do not constitute a hazard to animals, including humans, or the environment.

  17. Urinary selenium excretion in patients with cervical uterine cancer.

    Science.gov (United States)

    Navarrete, M; Gaudry, A; Revel, G; Martínez, T; Cabrera, L

    2001-02-01

    In this work, we report on a relationship between urinary selenium and the development of cervical uterine cancer. A simple chemical method was developed to concentrate trace amounts of selenium from relatively large urine samples by use of small activated carbon filters. When these filters are irradiated with thermal neutrons, selenium can be determined either by 77mSe (t1/2 = 17.5 s) or 75Se (t1/2 = 120 d). In this article, we report the results for 82 urine samples from women with cervical uterine cancer in several stages of development and from healthy controls. These results show a statistically significant increase of selenium excretion in cancer patients as compared to controls. Urinary selenium excretion is highest for patients in the intermediate stages of the disease.

  18. Selenium fertilization on lentil (Lens culinaris Medikus) grain yield, seed selenium concentration, and antioxidant activity

    Science.gov (United States)

    Selenium (Se) is an essential element for mammals but has not been considered as an essential element for higher plants. Lentil (Lens culinaris Medik.) is a cool season food legume rich in protein and a range of micronutrients including minerals (iron and zinc), folates, and carotenoids. The objecti...

  19. Biological production of selenium-biofortified products from natural-occurring sources of selenium

    Science.gov (United States)

    Health problems associated with soil selenium (Se) deficiency and its subsequent low accumulation by plants have become major nutritional issues in many countries. Of the many strategies employed to increase animal and human absorption of Se, biofortification is a recent technique that utilizes a pl...

  20. Total Selenium and Selenium Species in Irrigation Drain Inflows to the Salton Sea, California, April and July 2008

    Science.gov (United States)

    May, Thomas W.; Walther, Michael J.; Saiki, Michael K.; Brumbaugh, William G.

    2009-01-01

    This report presents the results for two sampling periods (April 2008 and July 2008) during a 4-year monitoring program to characterize selenium concentrations in selected irrigation drains flowing into the Salton Sea, California. Total selenium, selenium species (dissolved selenite, selenate, organoselenium), and total suspended solids were determined in water samples and total selenium was determined in water column particulates and in sediment, detritus, and biota that included algae, plankton, midge larvae (family, Chironomidae), and two fish species - western mosquitofish (Gambusia affinis) and sailfin molly (Poecilia latipinna). In addition, sediments were analyzed for percent total organic carbon and particle size. Mean total selenium concentrations in water for both sampling periods ranged from 1.93 to 44.2 micrograms per liter, predominately as selenate, which is typical of waters where selenium is leached out of selenium-containing marine shales and associated soils under alkaline and oxidizing conditions. Total selenium concentrations (micrograms per gram dry weight) ranged as follows: algae, 0.75 to 3.39; plankton, 0.88 to 4.03; midges, 2.52 to 44.3; fish, 3.37 to 18.9; detritus, 1.11 to 13.6; sediment, 0.11 to 8.93.

  1. Total Selenium and Selenium Species in Irrigation Drain Inflows to the Salton Sea, California, October 2008 and January 2009

    Science.gov (United States)

    May, Thomas W.; Walther, Michael J.; Saiki, Michael K.; Brumbaugh, William G.

    2009-01-01

    This report presents the results for two sampling periods (October 2008 and January 2009) during a 4-year monitoring program to characterize selenium concentrations in selected irrigation drains flowing into the Salton Sea, California. Total selenium, selenium species (dissolved selenite, selenate, organoselenium), and total suspended solids were determined in water samples. Total selenium also was determined in water column particulates and in sediment, detritus, and biota that included algae, plankton, midge larvae (family, Chironomidae), and two fish species (western mosquitofish, Gambusia affinis, and sailfin molly, Poecilia latipinna). In addition, sediments were analyzed for percent total organic carbon and particle size. Mean total selenium concentrations in water for both sampling periods ranged from 1.00 to 33.6 micrograms per liter, predominately as selenate, which is typical of waters where selenium is leached out of selenium-containing marine shales and associated soils under alkaline and oxidizing conditions. Total selenium concentrations (micrograms per gram dry weight) ranged as follows: algae, 1.52 to 8.26; plankton, 0.79 to 3.66; midges, 2.68 to 50.6; fish, 3.09 to 30.4; detritus, 1.78 to 58.0; and sediment, 0.42 to 10.0.

  2. Total Selenium and Selenium Species in Irrigation Drain Inflows to the Salton Sea, California, October 2007 and January 2008

    Science.gov (United States)

    May, Thomas W.; Walther, Michael J.; Saiki, Michael K.; Brumbaugh, William G.

    2008-01-01

    This report presents the results for two sampling periods (October 2007 and January 2008) during a 4-year monitoring program to characterize selenium concentrations in selected irrigation drains flowing into the Salton Sea, California. Total selenium, selenium species (selenite, selenate, organoselenium), and total suspended solids were determined in water samples, and total selenium was determined in sediment, detritus, and biota that included algae, plankton, midge larvae (family, Chironomidae), and two fish species?western mosquitofish (Gambusia affinis) and sailfin molly (Poecilia latipinna). In addition, sediments were analyzed for percent total organic carbon and particle size. Mean total selenium concentrations in water for both sampling periods ranged from 0.97 to 64.5 micrograms per liter, predominately as selenate, which is typical of waters where selenium is leached out of selenium-containing marine shales and associated soils under alkaline and oxidizing conditions. Total selenium concentrations (micrograms per gram dry weight) ranged as follows: algae, 0.95 to 5.99; plankton, 0.15 to 19.3; midges, 1.39 to 15.4; fish, 3.71 to 25.1; detritus, 0.85 to 21.7; sediment, 0.32 to 7.28.

  3. On Structure and Properties of Amorphous Materials

    Directory of Open Access Journals (Sweden)

    Zbigniew H. Stachurski

    2011-09-01

    Full Text Available Mechanical, optical, magnetic and electronic properties of amorphous materials hold great promise towards current and emergent technologies. We distinguish at least four categories of amorphous (glassy materials: (i metallic; (ii thin films; (iii organic and inorganic thermoplastics; and (iv amorphous permanent networks. Some fundamental questions about the atomic arrangements remain unresolved. This paper focuses on the models of atomic arrangements in amorphous materials. The earliest ideas of Bernal on the structure of liquids were followed by experiments and computer models for the packing of spheres. Modern approach is to carry out computer simulations with prediction that can be tested by experiments. A geometrical concept of an ideal amorphous solid is presented as a novel contribution to the understanding of atomic arrangements in amorphous solids.

  4. The physics and applications of amorphous semiconductors

    CERN Document Server

    Madan, Arun

    1988-01-01

    This comprehensive, detailed treatise on the physics and applications of the new emerging technology of amorphous semiconductors focuses on specific device research problems such as the optimization of device performance. The first part of the book presents hydrogenated amorphous silicon type alloys, whose applications include inexpensive solar cells, thin film transistors, image scanners, electrophotography, optical recording and gas sensors. The second part of the book discusses amorphous chalcogenides, whose applications include electrophotography, switching, and memory elements. This boo

  5. Deletion of apolipoprotein E receptor-2 in mice lowers brain selenium and causes severe neurological dysfunction and death when a low-selenium diet is fed.

    Science.gov (United States)

    Burk, Raymond F; Hill, Kristina E; Olson, Gary E; Weeber, Edwin J; Motley, Amy K; Winfrey, Virginia P; Austin, Lori M

    2007-06-01

    Selenoprotein P (Sepp1) is a plasma and extracellular protein that is rich in selenium. Deletion of Sepp1 results in sharp decreases of selenium levels in the brain and testis with dysfunction of those organs. Deletion of Sepp1 also causes increased urinary selenium excretion, leading to moderate depletion of whole-body selenium. The lipoprotein receptor apolipoprotein E receptor-2 (apoER2) binds Sepp1 and facilitates its uptake by Sertoli cells, thus providing selenium for spermatogenesis. Experiments were performed to assess the effect of apoER2 on the concentration and function of selenium in the brain and on whole-body selenium. ApoER2-/- and apoER2+/+ male mice were fed a semipurified diet with selenite added as the source of selenium. ApoER2-/- mice had depressed brain and testis selenium, but normal levels in liver, kidney, muscle, and the whole body. Feeding a selenium-deficient diet to apoER2-/- mice led to neurological dysfunction and death, with some of the characteristics exhibited by Sepp1-/- mice fed the same diet. Thus, although it does not affect whole-body selenium, apoER2 is necessary for maintenance of brain selenium and for prevention of neurological dysfunction and death under conditions of selenium deficiency, suggesting an interaction of apoER2 with Sepp1 in the brain.

  6. Structural study of amorphous polyaniline

    Science.gov (United States)

    Laridjani, M.; Pouget, J. P.; MacDiarmid, A. G.; Epstein, A. J.

    1992-06-01

    Many materials, especially polymers, have a substantial volume fraction with no long range crystalline order. Through these regions are often termed amorphous, they frequently have a specific local order. We describe and use here a method, base on a non-energy dispersive X-ray diffraction technique, to obtain good quality interference functions and, by Fourier transform, radial distribution functions of the amorphous structure of polymers. We apply this approach to members of a family of electronic polymers of current interest : polyaniline emeraldine bases. We show that the local order exhibits significant differences in type I and type II materials, precipitated as salt and base respectively. These studies demonstrate the importance of sample preparation in evaluating the physical properties of polyaniline, and provide a structural origin for memory effects observed in the doping-dedoping processes. Beaucoup de matériaux, spécialement les polymères, ont une importante fraction de leur volume sans ordre cristallin à longue portée. Bien que ces régions soient souvent appelées amorphes, elles présentent fréquemment un ordre local caractéristique. Nous décrivons et utilisons dans ce papier une méthode, basée sur une technique de diffraction de rayons X non dispersive en énergie, pour obtenir des fonctions d'interférence de bonne qualité et, par transformée de Fourier, la fonction de distribution radiale des polymères amorphes. Nous appliquons cette technique à plusieurs éléments d'une même famille de polymères électroniques d'intérêt actuel : les polyanilines éméraldine bases. Nous montrons que l'ordre local présente d'appréciables différences dans les matériaux de type I et II, préparés respectivement sous forme de sel et de base. Cette étude démontre l'importance des conditions de préparation sur les propriétés physiques du polyaniline et donne une base structurale aux effets observés dans les processus de dopage-dédopage de

  7. Electrical and switching properties of InSe amorphous thin films

    Energy Technology Data Exchange (ETDEWEB)

    Kenawy, M.A.; Zayed, H.A.; El-Zahid, H.A. (Univ. Coll. for Girls, Ain Shams Univ., Cairo (Egypt)); El-Shazly, A.F.; Afifi, M.A. (Faculty of Education, Ain Shams Univ., Cairo (Egypt))

    1991-05-15

    In this work electrical and switching properties of InSe thin films have been studied. The semiconductor compound InSe was obtained by direct synthesis from stoichiometric amounts of spectroscopically pure indium and selenium. By slow cooling of the synthesized InSe a polycrystalline material is obtained. The amorphous films were obtained by thermal evaporation under vacuum of the polycrystalline material on glass or pyrographite substrates. From electrical measurements, it was found that for all films the dark electrical resistivity decreases with an increase in film thickness and temperature. The InSe compound exhibits non-linear I-V characteristics and switching phenomena. The threshold voltage decreases with increasing annealing temperature and increases with increasing film thickness. (orig.).

  8. Preliminary Study on the Standard of Selenium Content in Agricultural Products

    Institute of Scientific and Technical Information of China (English)

    ZHANG Zhi-yuan; YOU Yong; GUO Qing-quan; WANG Yong-hong; DENG Shi-lin

    2012-01-01

    With the improvement of living standards, people pay more attention to the agricultural products with health protection function, and the selenium-rich agricultural products attract more and more consumers. The main biological role of selenium is to resist oxidation and inflammatory response, mainly focusing on resisting aging, preventing cardiovascular disease, protecting eyesight, counteracting or destroying the toxic properties, preventing cancer and thyroid disease. In most areas of China, there is a widespread shortage of selenium, thus producing selenium-rich agricultural products to provide natural selenium-rich health food to the areas in need of selenium, has gradually become a new hot spot of China’s health food industry, but high content of selenium in food is detrimental to human body, even leads to selenium intoxication, and artificially adding inorganic selenium is difficult to guarantee that the selenium content of agricultural products is not exceeded. According to human body’s daily demand for selenium in dietetics and the content of selenium in agricultural products in the Chinese food composition table, we put forward the recommendations on the standard of selenium in agricultural products, in order to provide the basis for China to formulate the health standard of selenium content in selenium-rich agricultural products.

  9. Selenium in blood, semen, seminal plasma and spermatozoa of stallions and its relationship to sperm quality.

    Science.gov (United States)

    Bertelsmann, H; Keppler, S; Höltershinken, M; Bollwein, H; Behne, D; Alber, D; Bukalis, G; Kyriakopoulos, A; Sieme, H

    2010-01-01

    The essential trace element selenium is indispensable for male fertility in mammals. Until now, little data existed regarding the relationship between selenium and sperm quality in the stallion. Selenium, or selenium-dependent glutathione peroxidase activity, was determined in red blood cells, semen, seminal plasma and spermatozoa, and the percentages of spermatozoa with progressive motility (PMS), intact membranes (PMI), altered (positive) acrosomal status (PAS) and detectable DNA damage, determined by the sperm chromatin structure assay, were evaluated in 41 healthy stallions (three samples each). The pregnancy rate per oestrus cycle (PRC) served as an estimation of fertility. An adverse effect on stallion fertility caused by low dietary selenium intake was excluded, as all stallions had sufficient selenium levels in their blood. Interestingly, no significant correlations (P > 0.05) between the selenium level in blood and the selenium level in seminal plasma or spermatozoa were found, suggesting that the selenium level in blood is no indicator of an adequate selenium supply for spermatogenesis. The selenium level in spermatozoa (nmol billion(-1)) was correlated with PMI, PMS and PAS (r = 0.40, r = 0.31 and r = -0.42, respectively; P selenium concentration in spermatozoa (nmol g(-1)) was correlated with PRC (r = 0.40, P selenium status for the male equine reproduction requires the analysis of selenium in spermatozoa. Furthermore, selenium is associated with improved sperm quality and fertility in the stallion.

  10. Study on the sustained-release profile of nano selenium chitosan composite%纳米硒-壳聚糖复合物缓释作用研究

    Institute of Scientific and Technical Information of China (English)

    吴永军

    2012-01-01

    High scattered red amorphous nano selenium was synthesized in the presence of food-grade sodium alginate,employing SeO2 and NH2OH·HCl as the reactants.Then Nano selenium/chitosan composite particles were synthesized by compounding Nano selenium with chitosan and corn starch.The selenium sustained-release behavior of complex had been studied in simulation digestive juice,some factors influencing the release rate of selenium were systematically investigated,such as the pOH of simulation digestive juice,the sustained-release temperature and time.Experiments showed that Nano selenium complex was fit for slow-release.The optimal sustained-release conditions as follows:the pOH of simulation digestive juice was 12.8,sustained-release temperature was 38℃,sustained-release time was 2.8h.Under the condition,the release rate of selenium was up to 68.43%.The analysis capability of model was significant as the relative error between experimental result and model predicted value was 0.48%.%以盐酸羟胺、亚硒酸为反应物,食品级海藻酸钠为软模板,制备了分散性良好的红色无定形纳米硒。辅以壳聚糖、玉米淀粉,合成出了纳米硒-壳聚糖复合颗粒,在模拟消化液中研究了复合物的硒缓释行为,考察了模拟消化液pOH、缓释温度、缓释时间对硒释放率的影响。结果表明,含硒复合物适合于缓释,最佳缓释条件为:模拟消化液pOH=12.80,缓释温度38℃,缓释2.8h,纳米硒-壳聚糖复合物的硒释放率达到68.43%,实测结果与模型预测值的相对误差仅为0.48%。

  11. Serum selenium level and risk of lung cancer mortality

    DEFF Research Database (Denmark)

    Suadicani, P; Hein, H O; Gyntelberg, F

    2011-01-01

    Serum selenium has been implicated as a risk factor for lung cancer, but the issue remains unsettled. We tested in a cohort of 3,333 males aged 53 to 74 years the hypothesis that a low serum selenium would be associated with an increased risk of lung cancer mortality.During 16 years, 167 subjects(5.......1%) died from lung cancer; 48 males (5.0%) among males with low serum selenium, 0.4-1.0 μmol·l(-1), n=965, 57 males (5.1%) among males with medium serum selenium, 1.1-1.2 μmol·l(-1), n=1,141, and 62 males (5.1%) among males with high serum selenium, 1.3-3.0 μmol·l(-1), n=1,227. After adjustment for age...... (chronic bronchitis and peak flow), referencing the lowest level of serum selenium HRs were 1.17(0.79-1.75), and 1.43(0.96-2.14), respectively. Among heavy smokers a high serum selenium was associated with a significantly increased risk of lung cancer mortality after taking into account all potential...

  12. Genome-Wide Association Study of Serum Selenium Concentrations

    Directory of Open Access Journals (Sweden)

    Ulrike Peters

    2013-05-01

    Full Text Available Selenium is an essential trace element and circulating selenium concentrations have been associated with a wide range of diseases. Candidate gene studies suggest that circulating selenium concentrations may be impacted by genetic variation; however, no study has comprehensively investigated this hypothesis. Therefore, we conducted a two-stage genome-wide association study to identify genetic variants associated with serum selenium concentrations in 1203 European descents from two cohorts: the Prostate, Lung, Colorectal, and Ovarian (PLCO Cancer Screening and the Women’s Health Initiative (WHI. We tested association between 2,474,333 single nucleotide polymorphisms (SNPs and serum selenium concentrations using linear regression models. In the first stage (PLCO 41 SNPs clustered in 15 regions had p < 1 × 10−5. None of these 41 SNPs reached the significant threshold (p = 0.05/15 regions = 0.003 in the second stage (WHI. Three SNPs had p < 0.05 in the second stage (rs1395479 and rs1506807 in 4q34.3/AGA-NEIL3; and rs891684 in 17q24.3/SLC39A11 and had p between 2.62 × 10−7 and 4.04 × 10−7 in the combined analysis (PLCO + WHI. Additional studies are needed to replicate these findings. Identification of genetic variation that impacts selenium concentrations may contribute to a better understanding of which genes regulate circulating selenium concentrations.

  13. Iodine and Selenium Intakes of Postmenopausal Women in New Zealand

    Science.gov (United States)

    Brough, Louise; Gunn, Caroline A.; Weber, Janet L.; Coad, Jane; Jin, Ying; Thomson, Jasmine S.; Mauze, Mathilde; Kruger, Marlena C.

    2017-01-01

    Iodine and selenium are required for thyroid function. This study investigated iodine and selenium intakes in healthy, women aged 50–70 years (n = 97) from three cities in the North Island of New Zealand, after mandatory fortification of bread with iodised salt. Iodine and selenium concentrations were determined in 24-h urine samples; daily intakes were extrapolated from amounts in urine (90% and 55% of daily intake, respectively). Three day diet diaries (3DDD) also estimated selenium and iodine (excluding iodised salt) intake. Median urinary iodine concentration (UIC) was 57 (41, 78) µg/L, indicating mild iodine deficiency. Estimated median iodine intake based on urine was 138 (100, 172) µg/day, below Recommended Dietary Intake (RDI) (150 µg/day) with 25% below Estimated Average Requirement (EAR) (100 µg/day). Estimated median selenium intake was 50 (36, 71) µg/day based on urine and 45 (36, 68) µg/day using 3DDD, below RDI (60 µg/day) with 49%–55% below EAR (50 µg/day). Median bread intakes were low at 1.8 (1.1, 2.7) serves/day; 25% consumed ≤1 serve/day. Although population iodine intakes improved following mandatory fortification, some had low intakes. Selenium intakes remain low. Further research should investigate thyroid function of low consumers of iodine fortified bread and/or selenium in New Zealand. PMID:28282932

  14. Prevention of rat breast cancer by genistin and selenium.

    Science.gov (United States)

    Hamdy, Soha M; Latif, Abdel Karim M Abdel; Drees, Ehab A; Soliman, Sahar M

    2012-09-01

    Breast cancer is the second leading cause of cancer death among women and the third most common cancer. In this study, we investigated the chemoprevention efficacy of each of soy genistin, selenium or a combination of them against breast cancer. Seventy-five female rats were divided into five groups : control group (I); 7,12-dimethylbenz(a)anthracene (DMBA) group (II); DMBA treated with genistin group (III); DMBA treated with selenium group (IV); and DMBA treated with genistin combined with selenium group (V). The treatments were daily administered for 3 months. There were a significant decrease in body weight and serum total antioxidant, while a significant elevation in serum total sialic acid, carcinoembryonic antigen, prolactin, estradiol, nitric oxide, and malondialdhyde of DMBA injected rats compared with control group. Administration of genistin and selenium was associated with decreasing levels of tumorigenicity, endocrine derangement, and oxidative stress. Formation of breast carcinoma in DMBA-induced rats and abnormal changes were ameliorated in the rats treated with genistin/selenium or genistin alone. Supplementation of genistin alone or with selenium provided antioxidant defense with high-potential chemopreventive activity against DMBA-induced mammary tumors more than selenium alone.

  15. Serum Selenium and Ceruloplasmin in Nigerians with Peripartum Cardiomyopathy

    Directory of Open Access Journals (Sweden)

    Kamilu M. Karaye

    2015-04-01

    Full Text Available The study aimed to determine if selenium deficiency, serum ceruloplasmin and traditional birth practices are risk factors for peripartum cardiomyopathy (PPCM, in Kano, Nigeria. This is a case-control study carried out in three hospitals, and PPCM patients were followed up for six months. Critically low serum selenium concentration was defined as <70 µg/L. A total of 39 PPCM patients and 50 controls were consecutively recruited after satisfying the inclusion criteria. Mean serum selenium in patients (61.7 ± 14.9 µg/L was significantly lower than in controls (118.4 ± 45.6 µg/L (p < 0.001. The prevalence of serum selenium <70 µg/L was significantly higher among patients (76.9% than controls (22.0% (p < 0.001. The mean ceruloplasmin and prevalence of socio-economic indices, multiparity, pregnancy-induced hypertension, obesity and twin pregnancy were not different between the groups (p > 0.05. Logistic regression showed that rural residency significantly increased the odds for serum selenium <70 µg/L by 2.773-fold (p = 0.037. Baseline serum levels of selenium and ceruloplasmin were not associated with six-month mortality. This study has shown that selenium deficiency is a risk factor for PPCM in Kano, Nigeria, and is related to rural residency. However, serum ceruloplasmin, customary birth practices and some other characteristics were not associated with PPCM in the study area.

  16. COMPARISON OF DETERMINING METHODS REGARDING SELENIUM CONTENT IN WHEAT PLANT

    Directory of Open Access Journals (Sweden)

    Mihaela Monica Stanciu-Burileanu

    2010-01-01

    Full Text Available As a metallic chemical element, selenium has received special attention from biologists because of its dual role as a trace element essential and toxic. The important part of enzymes that protect cells against the effects of free radicals that are produced during normal metabolism of oxygen. Also, selenium is essential for normal immune system and thyroid gland, The concentration of selenium in the soil, which varies by region, determines the default concentration of selenium in plants growing in the soil.The purpose of this paper is to present methods of comparison, dry oxidation at 450ºC and wet digestion – digestion with acids in high concentrations at microwave system digestion, for determining selenium content from wheat samples collected from the south-eastern part of Romania, namely Bărăgan Plain and Central-South Dobrogea. Selenium separation and dosage from obtained extracts carry out through a selective hydride generation atomic absorption spectrophotometry. With the software SURFER, a tendency map of selenium distribution was drawn.

  17. Selenium Nanoparticles for Stress-Resilient Fish and Livestock

    Science.gov (United States)

    Sarkar, Biplab; Bhattacharjee, Surajit; Daware, Akshay; Tribedi, Prosun; Krishnani, K. K.; Minhas, P. S.

    2015-09-01

    The fisheries and livestock sectors capture the highest share of protein-rich animal food and demonstrate accelerated growth as an agriculture subsidiary. Environmental pollution, climate change, as well as pathogenic invasions exert increasing stress impacts that lead the productivity momentum at a crossroads. Oxidative stress is the most common form of stress phenomenon responsible for the retardation of productivity in fisheries and livestock. Essential micronutrients play a determinant role in combating oxidative stress. Selenium, one of the essential micronutrients, appears as a potent antioxidant with reduced toxicity in its nanoscale form. In the present review, different methods of synthesis and characterization of nanoscale selenium have been discussed. The functional characterization of nano-selenium in terms of its effect on growth patterns, feed digestibility, and reproductive system has been discussed to elucidate the mechanism of action. Moreover, its anti-carcinogenic and antioxidant potentiality, antimicrobial and immunomodulatory efficacy, and fatty acid reduction in liver have been deciphered as the new phenomena of nano-selenium application. Biologically synthesized nano-selenium raises hope for pharmacologically enriched, naturally stable nanoscale selenium with high ecological viability. Hence, nano-selenium can be administered with commercial feeds for improvising stress resilience and productivity of fish and livestock.

  18. Laser surface treatment of amorphous metals

    Science.gov (United States)

    Katakam, Shravana K.

    Amorphous materials are used as soft magnetic materials and also as surface coatings to improve the surface properties. Furthermore, the nanocrystalline materials derived from their amorphous precursors show superior soft magnetic properties than amorphous counter parts for transformer core applications. In the present work, laser based processing of amorphous materials will be presented. Conventionally, the nanocrystalline materials are synthesized by furnace heat treatment of amorphous precursors. Fe-based amorphous/nanocrystalline materials due to their low cost and superior magnetic properties are the most widely used soft magnetic materials. However, achieving nanocrystalline microstructure in Fe-Si-B ternary system becomes very difficult owing its rapid growth rate at higher temperatures and sluggish diffusion at low temperature annealing. Hence, nanocrystallization in this system is achieved by using alloying additions (Cu and Nb) in the ternary Fe-Si-B system. Thus, increasing the cost and also resulting in reduction of saturation magnetization. laser processing technique is used to achieve extremely fine nanocrystalline microstructure in Fe-Si-B amorphous precursor. Microstructure-magnetic Property-laser processing co-relationship has been established for Fe-Si-B ternary system using analytical techniques. Laser processing improved the magnetic properties with significant increase in saturation magnetization and near zero coercivity values. Amorphous materials exhibit excellent corrosion resistance by virtue of their atomic structure. Fe-based amorphous materials are economical and due to their ease of processing are of potential interest to synthesize as coatings materials for wear and corrosion resistance applications. Fe-Cr-Mo-Y-C-B amorphous system was used to develop thick coatings on 4130 Steel substrate and the corrosion resistance of the amorphous coatings was improved. It is also shown that the mode of corrosion depends on the laser processing

  19. Nanostructured selenium for preventing biofilm formation on polycarbonate medical devices.

    Science.gov (United States)

    Wang, Qi; Webster, Thomas J

    2012-12-01

    Biofilms are a common cause of persistent infections on medical devices as they are easy to form and hard to treat. The objective of this study was for the first time to coat selenium (a natural element in the body) nanoparticles on the surface of polycarbonate medical devices (such as those used for medical catheters) and to examine their effectiveness at preventing biofilm formation. The size and distribution of selenium coatings were characterized using scanning electron microscopy and atomic force microscopy. The strength of the selenium coating on polycarbonate was assessed by tape-adhesion tests followed by atomic absorption spectroscopy. Results showed that selenium nanoparticles had a diameter of 50-100 nm and were well distributed on the polycarbonate surface. In addition, more than 50% of the selenium coating survived the tape-adhesion test as larger nanoparticles had less adhesion strength to the underlying polycarbonate substrate than smaller selenium nanoparticles. Most significantly, the results of this in vitro study showed that the selenium coatings on polycarbonate significantly inhibited Staphylococcus aureus growth to 8.9% and 27% when compared with an uncoated polycarbonate surface after 24 and 72 h, respectively. Importantly, this was accomplished without using antibiotics but rather with an element (selenium) that is natural to the human body. Thus, this study suggests that coating polymers (particularly, polycarbonate) with nanostructured selenium is a fast and effective way to reduce bacteria functions that lead to medical device infections. © 2012 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 100A: 3205-3210, 2012.

  20. The selenium-rich C-terminal domain of mouse selenoprotein P is necessary for the supply of selenium to brain and testis but not for the maintenance of whole body selenium.

    Science.gov (United States)

    Hill, Kristina E; Zhou, Jiadong; Austin, Lori M; Motley, Amy K; Ham, Amy-Joan L; Olson, Gary E; Atkins, John F; Gesteland, Raymond F; Burk, Raymond F

    2007-04-13

    Selenoprotein P (Sepp1) has two domains with respect to selenium content: the N-terminal, selenium-poor domain and the C-terminal, selenium-rich domain. To assess domain function, mice with deletion of the C-terminal domain have been produced and compared with Sepp1-/- and Sepp1+/+ mice. All mice studied were males fed a semipurified diet with defined selenium content. The Sepp1 protein in the plasma of mice with the C-terminal domain deleted was determined by mass spectrometry to terminate after serine 239 and thus was designated Sepp1Delta240-361. Plasma Sepp1 and selenium concentrations as well as glutathione peroxidase activity were determined in the three types of mice. Glutathione peroxidase and Sepp1Delta240-361 accounted for over 90% of the selenium in the plasma of Sepp1Delta240-361 mice. Calculations using results from Sepp1+/+ mice revealed that Sepp1, with a potential for containing 10 selenocysteine residues, contained an average of 5 selenium atoms per molecule, indicating that shortened and/or selenium-depleted forms of the protein were present in these wild-type mice. Sepp1Delta240-361 mice had low brain and testis selenium concentrations that were similar to those in Sepp1-/- mice but they better maintained their whole body selenium. Sepp1Delta240-361 mice had depressed fertility, even when they were fed a high selenium diet, and their spermatozoa were defective and morphologically indistinguishable from those of selenium-deficient mice. Neurological dysfunction and death occurred when Sepp1Delta240-361 mice were fed selenium-deficient diet. These phenotypes were similar to those of Sepp1-/- mice but had later onset or were less severe. The results of this study demonstrate that the C terminus of Sepp1 is critical for the maintenance of selenium in brain and testis but not for the maintenance of whole body selenium.

  1. Selenium Level and Dyslipidemia in Rural Elderly Chinese.

    Directory of Open Access Journals (Sweden)

    Liqin Su

    Full Text Available Higher selenium level has been hypothesized to have the potential to reduce the risk of cardiovascular diseases including dyslipidemia. However, results from previous studies are inconsistent. This study aims to determine the association between selenium level and dyslipidemia in elderly Chinese with relatively low selenium status.A cross-sectional study of 1859 participants aged 65 or older from four rural counties in China was conducted. Serum total cholesterol (TC, triglycerides (TG, high density lipoprotein-cholesterol (HDLC and low-density lipoprotein-cholesterol (LDLC, nail selenium concentration and APOE genotype were measured in all subjects. The four types of dyslipidemia were defined as >5.17 mmol/L for High-TC, >1.69 mmol/L for High-TG, >3.36 mmol/L for High-LDLC, and <1.04 mmol/L for Low-HDLC according to Chinese Guidelines on Prevention and Treatment of Dyslipidemia in Adults. Logistic models adjusting for age, gender, APOE genotype, body mass index, alcohol consumption, smoking, physical activity, medication use for cardiovascular diseases were used to examine the relationship between selenium levels and the risk of dyslipidemia.Mean nail selenium concentration was 0.465 μg/gin this sample. Rates for High-TC, High-LDLC, High-TG, Low-HDLC were 18.13%, 13.23%, 12.21% and 32.76% respectively. Results from logistic models indicated that higher selenium levels were significantly associated with higher risk of High-TC, High-LDLC and lower risk of Low-HDLC adjusting for covariates (p < 0.0001. Compared with the lowest selenium quartile group, participants in selenium quartile groups 2, 3 and 4 had significantly higher rates of High-TC, High-LDLC, High-TG, and lower rate of Low-HDLC adjusting for covariates. No significant association was observed between selenium level and the risk of High-TG. APOEε4 carriers had higher rates of High-TC and High-LDLC. There was no interaction between selenium level and APOE with the rates of

  2. An Introduction to Testing Web Applications with twill and Selenium

    CERN Document Server

    Brown, Titus; Huggins, Jason

    2007-01-01

    This Short Cut is an introduction tobuilding automated web tests using twotools, twill and Selenium. twill is a simpleweb scripting language that can be usedto automate web tests, while Selenium isa web testing framework that runs in anybrowser and can be used to test complexweb sites that make extensive use ofJavaScript. The best way to use this Short Cut is torun through the examples. We expectthat within an hour you can start writingyour own functional tests in either twillor Selenium, and within a day you willunderstand most, if not all, of the possibilitiesand the limitations of these t

  3. Selenium as an antidote in the treatment of mercury intoxication.

    Science.gov (United States)

    Bjørklund, Geir

    2015-08-01

    Selenium (Se) is an essential trace element for humans. It is found in the enzyme glutathione peroxidase. This enzyme protects the organism against certain types of damage. Some data suggest that Se plays a role in the body's metabolism of mercury (Hg). Selenium has in some studies been found to reduce the toxicity of Hg salts. Selenium and Hg bind in the body to each other. It is not totally clear what impact the amount of Se has in the human body on the metabolism and toxicity of prolonged Hg exposure.

  4. Microgravimetric Studies of Selenium Electrodeposition Onto Different Substrates

    Directory of Open Access Journals (Sweden)

    Kowalik R.

    2014-10-01

    Full Text Available The mechanism of selenium electrodeposition from sulfuric acid solution on different substrates was studied with the electrochemical techniques. The cyclic voltammetry was combined with the quartz crystal microbalance technique to analyze selenium deposition process. The electrochemical reduction of selenous acid on gold, silver and copper electrodes was investigated. It was found that reduction of selenous acid is a very complex process and it strongly depends from the applied substrate. The voltammetric measurements indicate the range of potentials in which the process of reduction of selenous acids on the applied substrate is possible. Additionally, the microgravimetric data confirm the deposition of selenium and they reveal the mechanism of the deposition process.

  5. Microstructural analyses of amorphic diamond, i-C, and amorphous carbon

    DEFF Research Database (Denmark)

    Collins, C. B.; Davanloo, F.; Jander, D.R.;

    1992-01-01

    Recent experiments have identified the microstructure of amorphic diamond with a model of packed nodules of amorphous diamond expected theoretically. However, this success has left in doubt the relationship of amorphic diamond to other noncrystalline forms of carbon. This work reports...... the comparative examinations of the microstructures of samples of amorphic diamond, i-C, and amorphous carbon. Four distinct morphologies were found that correlated closely with the energy densities used in preparing the different materials. Journal of Applied Physics is copyrighted by The American Institute...

  6. Selenium for the Prevention of Cutaneous Melanoma

    Directory of Open Access Journals (Sweden)

    Douglas Grossman

    2013-03-01

    Full Text Available The role of selenium (Se supplementation in cancer prevention is controversial; effects often depend on the nutritional status of the subject and on the chemical form in which Se is provided. We used a combination of in vitro and in vivo models to study two unique therapeutic windows for intervention in the process of cutaneous melanomagenisis, and to examine the utility of two different chemical forms of Se for prevention and treatment of melanoma. We studied the effects of Se in vitro on UV-induced oxidative stress in melanocytes, and on apoptosis and cell cycle progression in melanoma cells. In vivo, we used the HGF transgenic mouse model of UV-induced melanoma to demonstrate that topical treatment with l-selenomethionine results in a significant delay in the time required for UV-induced melanoma development, but also increases the rate of growth of those tumors once they appear. In a second mouse model, we found that oral administration of high dose methylseleninic acid significantly decreases the size of human melanoma xenografts. Our findings suggest that modestly elevation of selenium levels in the skin might risk acceleration of growth of incipient tumors. Additionally, certain Se compounds administered at very high doses could have utility for the treatment of fully-malignant tumors or prevention of recurrence.

  7. Bacterial respiration of arsenic and selenium

    Science.gov (United States)

    Stolz, J.F.; Oremland, R.S.

    1999-01-01

    Oxyanions of arsenic and selenium can be used in microbial anaerobic respiration as terminal electron acceptors. The detection of arsenate and selenate respiring bacteria in numerous pristine and contaminated environments and their rapid appearance in enrichment culture suggest that they are widespread and metabolically active in nature. Although the bacterial species that have been isolated and characterized are still few in number, they are scattered throughout the bacterial domain and include Gram- positive bacteria, beta, gamma and epsilon Proteobacteria and the sole member of a deeply branching lineage of the bacteria, Chrysiogenes arsenatus. The oxidation of a number of organic substrates (i.e. acetate, lactate, pyruvate, glycerol, ethanol) or hydrogen can be coupled to the reduction of arsenate and selenate, but the actual donor used varies from species to species. Both periplasmic and membrane-associated arsenate and selenate reductases have been characterized. Although the number of subunits and molecular masses differs, they all contain molybdenum. The extent of the environmental impact on the transformation and mobilization of arsenic and selenium by microbial dissimilatory processes is only now being fully appreciated.

  8. Pharmacology of selenium-containing compound

    Energy Technology Data Exchange (ETDEWEB)

    Abdullaev, R.A.; Gusenov, D.Ya.; Babakhanov, R.A.; Mirzoev, Kh.M.

    1985-09-01

    Selenium-containing compounds are used in increasing frequency in medicine; they affect biological indices of the human body showing anti-histamine and antioxidative activity; they can cause acute intoxication, promote tumor development in liver, and help regulate the functions of the retina. A selenium compound (I) was investigated in depth. I was a colorless, crystalline powder, soluble in water with a molecular weight of 341.5, and elemental composition C/sub 13/H/sub 25/SeNO/sub 2/. On the basis of experimental data, its LD/sub 50/ on s.c. administration to white mice was 600 mg/kg. I.v. injections of I in doses of 25-50 mg/kg showed no significant effect on the heart activity. A 75 mg/kg dose was fatal within 1-2 minutes after an i.v. administration. I.V. injection to cats at a dose of 50 mg/kg resulted in a transient drop of the arterial pressure which returned to normal after 5-10 minutes. The respiration rate and its amplitude decreased and returned gradually to normal level after 20-30 minutes. 18 references, 2 figures.

  9. Biofortification and phytoremediation of selenium in China

    Directory of Open Access Journals (Sweden)

    Zhilin eWu

    2015-03-01

    Full Text Available Selenium (Se is an essential trace element for humans and animals but at high concentrations, Se becomes toxic to organisms due to Se replacing sulfur in proteins. Selenium biofortification is an agricultural process that increases the accumulation of Se in crops, through plant breeding, genetic engineering, or use of Se fertilizers. While Se phytoremediation is a green biotechnology to clean up Se-contaminated environments, primarily through phytoextraction and phytovolatilization. By integrating Se phytoremediation and biofortification technologies, Se-enriched plant materials harvested from Se phytoremediation can be used as Se-enriched green manures or other supplementary sources of Se for producing Se-biofortified agricultural products. Earlier studies primarily aimed at enhancing efficacy of phytoremediation and biofortification of Se based on natural variation in progenitor or identification of unique plant species. In this review, we discuss promising approaches to improve biofortification and phytoremediation of Se using knowledge acquired from model crops. We also explored the feasibility of applying biotechnologies such as inoculation of microbial strains for improving the efficiency of biofortification and phytoremediation of Se. The key research and practical challenges that remain in improving biofortification and phytoremediation of Se have been highlighted, and the future development and uses of Se-biofortified agricultural products in China has also been discussed.

  10. Selenium toxicosis in wild aquatic birds

    Science.gov (United States)

    Ohlendorf, H.M.; Kilness, A.W.; Simmons, J.L.; Stroud, R.K.; Hoffman, D.J.; Moore, John F.

    1988-01-01

    Severe gross and microscopic lesions and other changes were found in adult aquatic birds and in embryos from Kesterson Reservoir (a portion of Kesterson National Wildlife Refuge), Merced County, Calif., during 1984. Adult birds from that area were emaciated, had subacute to extensive chronic hepatic lesions, and had excess fluid and fibrin in the peritoneal cavity. Biochemical changes in their livers included elevated glycogen and non-protein-bound sulfhydryl concentrations and glutathione peroxidase activity but lowered protein, total sulfhydryl, and protein-bound sulfhydryl concentrations. Congenital malformations observed grossly in embryos were often multiple and included anophthalmia, microphthalmia, abnormal beaks, amelia, micromelia, ectrodactyly, and hydrocephaly. Mean concentrations of selenium in livers (94.4 ppm, dry weight) and kidneys (96.6 ppm) of birds collected at the Kesterson ponds were about 10 times those found at a nearby control area (8.3 and 12.2 ppm). We conclude that selenium present in the agricultural drainage water supplied to the Kesterson ponds accumulated in the food chain of aquatic birds to toxic concentrations and caused the lesion and other changes observed.

  11. Total Selenium and Selenium Species in Irrigation Drain Inflows to the Salton Sea, California, April and July 2007

    Science.gov (United States)

    May, Thomas W.; Walther, Michael J.; Saiki, Michael K.; Brumbaugh, William G.

    2007-01-01

    This report presents the results for two sampling periods during a 4-year monitoring survey to provide a characterization of selenium concentrations in selected irrigation drains flowing into the Salton Sea, California. Total selenium, selenium species, and total suspended solids were determined in water samples, and total selenium was determined in sediment, detritus, and biota that included algae, plankton, midge larvae (family, Chironomidae), and two fish species-western mosquitofish (Gambusia affinis), and sailfin molly (Poecilia latipinna). In addition, sediments were analyzed for percent total organic carbon and particle size. Total selenium concentrations in water for both sampling periods ranged from 1.43 to 47.1 micrograms per liter, predominately as selenate, which is typical of waters leached out of selenium-contaminated marine shales under alkaline and oxidizing conditions. Total selenium concentrations ranged from 0.88 to 20.2 micrograms per gram in biota, and from 0.15 to 28.9 micrograms per gram in detritus and sediment.

  12. Biochemical discrimination between selenium and sulfur 1: a single residue provides selenium specificity to human selenocysteine lyase.

    Directory of Open Access Journals (Sweden)

    Ruairi Collins

    Full Text Available Selenium and sulfur are two closely related basic elements utilized in nature for a vast array of biochemical reactions. While toxic at higher concentrations, selenium is an essential trace element incorporated into selenoproteins as selenocysteine (Sec, the selenium analogue of cysteine (Cys. Sec lyases (SCLs and Cys desulfurases (CDs catalyze the removal of selenium or sulfur from Sec or Cys and generally act on both substrates. In contrast, human SCL (hSCL is specific for Sec although the only difference between Sec and Cys is the identity of a single atom. The chemical basis of this selenium-over-sulfur discrimination is not understood. Here we describe the X-ray crystal structure of hSCL and identify Asp146 as the key residue that provides the Sec specificity. A D146K variant resulted in loss of Sec specificity and appearance of CD activity. A dynamic active site segment also provides the structural prerequisites for direct product delivery of selenide produced by Sec cleavage, thus avoiding release of reactive selenide species into the cell. We thus here define a molecular determinant for enzymatic specificity discrimination between a single selenium versus sulfur atom, elements with very similar chemical properties. Our findings thus provide molecular insights into a key level of control in human selenium and selenoprotein turnover and metabolism.

  13. Bulk amorphous Mg-based alloys

    DEFF Research Database (Denmark)

    Pryds, Nini

    2004-01-01

    The present paper describes the preparation and properties of bulk amorphous quarternary Mg-based alloys and the influence of additional elements on the ability of the alloy to form bulk amorphous. The main goal is to find a Mg-based alloy system which shows both high strength to weight ratio and...

  14. Photoexcitation-induced processes in amorphous semiconductors

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Jai [School of Engineering and Logistics, Charles Darwin University, Darwin, NT 0909 (Australia)]. E-mail: jai.singh@cdu.edu.au

    2005-07-30

    Theories for the mechanism of photo-induced processes of photodarkening (PD), volume expansion (VE) in amorphous chalcogenides are presented. Rates of spontaneous emission of photons by radiative recombination of excitons in amorphous semiconductors are also calculated and applied to study the excitonic photoluminescence in a-Si:H. Results are compared with previous theories.

  15. Band Gaps of an Amorphous Photonic Materials

    Institute of Scientific and Technical Information of China (English)

    WANG Yi-Quan; FENG Zhi-Fang; HU Xiao-Yong; CHENG Bing-Ying; ZHANG Dao-Zhong

    2004-01-01

    @@ A new kind of amorphous photonic materials is presented. Both the simulated and experimental results show that although the disorder of the whole dielectric structure is strong, the amorphous photonic materials have two photonic gaps. This confirms that the short-range order is an essential factor for the formation of the photonic gaps.

  16. Co amorphous systems: A product development perspective.

    Science.gov (United States)

    Chavan, Rahul B; Thipparaboina, Rajesh; Kumar, Dinesh; Shastri, Nalini R

    2016-12-30

    Solubility is one of the major problems associated with most of the new chemical entities that can be reasonably addressed by drug amorphization. However, being a high-energy form, it usually tends to re-crystallize, necessitating new formulation strategies to stabilize amorphous drugs. Polymeric amorphous solid dispersion (PASD) is one of the widely investigated strategies to stabilize amorphous drug, with major limitations like limited polymer solubility and hygroscopicity. Co amorphous system (CAM), a new entrant in amorphous arena is a promising alternative to PASD. CAMs are multi component single phase amorphous solid systems made up of two or more small molecules that may be a combination of drugs or drug and excipients. Excipients explored for CAM preparation include amino acids, carboxylic acids, nicotinamide and saccharine. Advantages offered by CAM include improved aqueous solubility and physical stability of amorphous drug, with a potential to improve therapeutic efficacy. This review attempts to address different aspects in the development of CAM as drug products. Criterion for co-former selection, various methods involved in CAM preparation, characterization tools, stability, scale up and regulatory requirements for the CAM product development are discussed.

  17. Electron beam recrystallization of amorphous semiconductor materials

    Science.gov (United States)

    Evans, J. C., Jr.

    1968-01-01

    Nucleation and growth of crystalline films of silicon, germanium, and cadmium sulfide on substrates of plastic and glass were investigated. Amorphous films of germanium, silicon, and cadmium sulfide on amorphous substrates of glass and plastic were converted to the crystalline condition by electron bombardment.

  18. Selenium Speciation and Management in Wet FGD Systems

    Energy Technology Data Exchange (ETDEWEB)

    Searcy, K; Richardson, M; Blythe, G; Wallschlaeger, D; Chu, P; Dene, C

    2012-02-29

    This report discusses results from bench- and pilot-scale simulation tests conducted to determine the factors that impact selenium speciation and phase partitioning in wet FGD systems. The selenium chemistry in wet FGD systems is highly complex and not completely understood, thus extrapolation and scale-up of these results may be uncertain. Control of operating parameters and application of scrubber additives have successfully demonstrated the avoidance or decrease of selenite oxidation at the bench and pilot scale. Ongoing efforts to improve sample handling methods for selenium speciation measurements are also discussed. Bench-scale scrubber tests explored the impacts of oxidation air rate, trace metals, scrubber additives, and natural limestone on selenium speciation in synthetic and field-generated full-scale FGD liquors. The presence and concentration of redox-active chemical species as well as the oxidation air rate contribute to the oxidation-reduction potential (ORP) conditions in FGD scrubbers. Selenite oxidation to the undesirable selenate form increases with increasing ORP conditions, and decreases with decreasing ORP conditions. Solid-phase manganese [Mn(IV)] appeared to be the significant metal impacting the oxidation of selenite to selenate. Scrubber additives were tested for their ability to inhibit selenite oxidation. Although dibasic acid and other scrubber additives showed promise in early clear liquor (sodium based and without calcium solids) bench-scale tests, these additives did not show strong inhibition of selenite oxidation in tests with higher manganese concentrations and with slurries from full-scale wet FGD systems. In bench-tests with field liquors, addition of ferric chloride at a 250:1 iron-to-selenium mass ratio sorbed all incoming selenite to the solid phase, although addition of ferric salts had no impact on native selenate that already existed in the field slurry liquor sample. As ORP increases, selenite may oxidize to selenate more

  19. Effects of Dietary Selenium, Sulphur and Copper Levels on Selenium Concentration in the Serum and Liver of Lamb

    Science.gov (United States)

    Netto, Arlindo Saran; Zanetti, Marcus Antonio; Correa, Lisia Bertonha; Del Claro, Gustavo Ribeiro; Salles, Márcia Saladini Vieira; Vilela, Flávio Garcia

    2014-01-01

    Thirty-two lambs were distributed in eight treatments under 2×2×2 factorial experiment to compare the effects of two levels of selenium (0.2 to 5 mg/kg dry matter [DM]), sulphur (0.25% and 0.37%) and copper (8 and 25 mg/kg DM) levels on selenium concentration in liver and serum of lambs. A liver biopsy was done on all animals and blood samples were collected from the jugular vein prior to the beginning of the treatments. The blood was sampled every thirty days and the liver was sampled after 90 days, at the slaughter. Increasing differences were noticed during the data collection period for the serum selenium concentration, and it was found to be 0.667 mg/L in animals fed with 5 mg Se/kg DM and normal sulphur and copper concentrations in their diet. However, a three-way interaction and a reduction of selenium concentration to 0.483 mg/L was verified when increasing copper and sulphur concentration levels to 25 ppm and 0.37% respectively. The liver selenium concentration was also high for diets containing higher selenium concentrations, but the antagonist effect with the increased copper and sulphur levels remained, due to interactions between these minerals. Therefore, for regions where selenium is scarce, increasing its concentration in animal diets can be an interesting option. For regions with higher levels of selenium, the antagonistic effect of interaction between these three minerals should be used by increasing copper and sulphur dietary concentrations, thus preventing possible selenium poisoning. PMID:25083101

  20. Effects of dietary selenium, sulphur and copper levels on selenium concentration in the serum and liver of lamb.

    Science.gov (United States)

    Netto, Arlindo Saran; Zanetti, Marcus Antonio; Correa, Lisia Bertonha; Del Claro, Gustavo Ribeiro; Salles, Márcia Saladini Vieira; Vilela, Flávio Garcia

    2014-08-01

    Thirty-two lambs were distributed in eight treatments under 2×2×2 factorial experiment to compare the effects of two levels of selenium (0.2 to 5 mg/kg dry matter [DM]), sulphur (0.25% and 0.37%) and copper (8 and 25 mg/kg DM) levels on selenium concentration in liver and serum of lambs. A liver biopsy was done on all animals and blood samples were collected from the jugular vein prior to the beginning of the treatments. The blood was sampled every thirty days and the liver was sampled after 90 days, at the slaughter. Increasing differences were noticed during the data collection period for the serum selenium concentration, and it was found to be 0.667 mg/L in animals fed with 5 mg Se/kg DM and normal sulphur and copper concentrations in their diet. However, a three-way interaction and a reduction of selenium concentration to 0.483 mg/L was verified when increasing copper and sulphur concentration levels to 25 ppm and 0.37% respectively. The liver selenium concentration was also high for diets containing higher selenium concentrations, but the antagonist effect with the increased copper and sulphur levels remained, due to interactions between these minerals. Therefore, for regions where selenium is scarce, increasing its concentration in animal diets can be an interesting option. For regions with higher levels of selenium, the antagonistic effect of interaction between these three minerals should be used by increasing copper and sulphur dietary concentrations, thus preventing possible selenium poisoning.

  1. Neutron irradiation induced amorphization of silicon carbide

    Energy Technology Data Exchange (ETDEWEB)

    Snead, L.L.; Hay, J.C. [Oak Ridge National Lab., TN (United States)

    1998-09-01

    This paper provides the first known observation of silicon carbide fully amorphized under neutron irradiation. Both high purity single crystal hcp and high purity, highly faulted (cubic) chemically vapor deposited (CVD) SiC were irradiated at approximately 60 C to a total fast neutron fluence of 2.6 {times} 10{sup 25} n/m{sup 2}. Amorphization was seen in both materials, as evidenced by TEM, electron diffraction, and x-ray diffraction techniques. Physical properties for the amorphized single crystal material are reported including large changes in density ({minus}10.8%), elastic modulus as measured using a nanoindentation technique ({minus}45%), hardness as measured by nanoindentation ({minus}45%), and standard Vickers hardness ({minus}24%). Similar property changes are observed for the critical temperature for amorphization at this neutron dose and flux, above which amorphization is not possible, is estimated to be greater than 130 C.

  2. Tritiated amorphous silicon for micropower applications

    Energy Technology Data Exchange (ETDEWEB)

    Kherani, N.P. [Ontario Hydro Technologies, Toronto, Ontario (Canada)]|[Univ. of Toronto, Ontario (Canada); Kosteski, T.; Zukotynski, S. [Univ. of Toronto, Ontario (Canada); Shmayda, W.T. [Ontario Hydro Technologies, Toronto, Ontario (Canada)

    1995-10-01

    The application of tritiated amorphous silicon as an intrinsic energy conversion semiconductor for radioluminescent structures and betavoltaic devices is presented. Theoretical analysis of the betavoltaic application shows an overall efficiency of 18% for tritiated amorphous silicon. This is equivalent to a 330 Ci intrinsic betavoltaic device producing 1 mW of power for 12 years. Photoluminescence studies of hydrogenated amorphous silicon, a-Si:H, show emission in the infra-red with a maximum quantum efficiency of 7.2% at 50 K; this value drops by 3 orders of magnitude at a temperature of 300 K. Similar studies of hydrogenated amorphous carbon show emission in the visible with an estimated quantum efficiency of 1% at 300 K. These results suggest that tritiated amorphous carbon may be the more promising candidate for room temperature radioluminescence in the visible. 18 refs., 5 figs.

  3. Amorphous metals for radial airgap electric machines

    Energy Technology Data Exchange (ETDEWEB)

    Lu Ning; Kokernak, J.M. [Rensselaer Polytechnic Institute, Dept. of Electric Poer Engineering, Troy, NY (United States)

    2000-08-01

    Amorphous steel teas been in use for some time in the transformer industry. The difficulty associated with handling such a hard material paired with the extremely thin nature of the casting has prevented amorphous steel from being seriously considered for radial airgap electric motors. In light of recent advances in manufacturing and handling of the amorphous materials, this paper presents an investigation into the performance advantages of an amorphous brushless dc motor. A two-dimensional, time-stepped, finite element model is used to analyze the electromagnetic field and motor performance for an amorphous brushless dc (BLDC) motor and a M-l9 BLDC motor. Each is modeled with identical structure geometries. Magnetic core losses are also estimated for the two motors operating over a frequency range of 50 to 200 Hz. (orig.)

  4. EXAFS characterization of amorphous GaAs

    Energy Technology Data Exchange (ETDEWEB)

    Ridgway, M.C.; Glover, C.J. [Australia National Univ., Canberra (Australia); Foran, G.J. [Australian Nuclear Science and Technology Organization, Menai (Australia); Yu, K.M. [Lawrence Berkeley National Lab., CA (United States). Materials Sciences Div.

    1998-12-31

    The structural parameters of stoichiometric, amorphous GaAs have been determined with extended x-ray absorption fine structure (EXAFS) measurements performed in transmission mode at 10 K. Amorphous GaAs samples were fabricated with a combination of epitaxial growth, ion implantation and selective chemical etching. Relative to a crystalline sample, the nearest-neighbor bond length and Debye-Waller factor both increased for amorphous material. In contrast, the coordination numbers about both Ga and As atoms in the amorphous phase decreased to {approximately} 3.85 atoms from the crystalline value of four. All structural parameters were independent of implantation conditions and as a consequence, were considered representative of intrinsic, amorphous GaAs as opposed to an implantation-induced extrinsic structure.

  5. Solid-state diffusion in amorphous zirconolite

    Energy Technology Data Exchange (ETDEWEB)

    Yang, C.; Dove, M. T.; Trachenko, K. [School of Physics and Astronomy, Queen Mary University of London, Mile End Road, London E1 4NS (United Kingdom); Zarkadoula, E. [School of Physics and Astronomy, Queen Mary University of London, Mile End Road, London E1 4NS (United Kingdom); Materials Science and Technology Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831-6138 (United States); Todorov, I. T. [STFC Daresbury Laboratory, Warrington WA4 1EP (United Kingdom); Geisler, T. [Steinmann-Institut für Geologie, Mineralogie und Paläontologie, University of Bonn, D-53115 Bonn (Germany); Brazhkin, V. V. [Institute for High Pressure Physics, RAS, 142190 Moscow (Russian Federation)

    2014-11-14

    We discuss how structural disorder and amorphization affect solid-state diffusion, and consider zirconolite as a currently important case study. By performing extensive molecular dynamics simulations, we disentangle the effects of amorphization and density, and show that a profound increase of solid-state diffusion takes place as a result of amorphization. Importantly, this can take place at the same density as in the crystal, representing an interesting general insight regarding solid-state diffusion. We find that decreasing the density in the amorphous system increases pre-factors of diffusion constants, but does not change the activation energy in the density range considered. We also find that atomic species in zirconolite are affected differently by amorphization and density change. Our microscopic insights are relevant for understanding how solid-state diffusion changes due to disorder and for building predictive models of operation of materials to be used to encapsulate nuclear waste.

  6. Drug-excipient behavior in polymeric amorphous solid dispersions.

    OpenAIRE

    Surikutchi Bhanu Teja; Shashank Pralhad Patil; Ganesh Shete; Sarsvatkumar Patel; Arvind Kumar Bansal

    2016-01-01

    Amorphous drug delivery systems are increasingly utilized to enhance aqueous solubility and oral bioavailability. However, they lack physical and/or chemical stability. One of the most common ways of stabilizing an amorphous form is by formulating it as an amorphous solid dispersion. This review focuses on polymeric amorphous solid dispersions wherein polymers are used as excipients to stabilize the amorphous form. A brief introduction to the basic concepts of amorphous systems such as glass ...

  7. Drug excipient behavior in polymeric amorphous solid dispersions

    OpenAIRE

    Bhanu Teja Surikutchi; Shashank Pralhad Patil; Ganesh Shete; Sarsvatkumar Patel; Arvind Kumar Bansal

    2013-01-01

    Amorphous drug delivery system is being increasingly utilized for enhancing aqueous solubility and oral bioavailability. However it suffers from lack of physical/chemical stability. One of the most common ways of stabilizing an amorphous form is by formulating it as amorphous solid dispersion. This review focuses on the polymeric amorphous solid dispersion wherein polymers are used as excipients to stabilize the amorphous form. We present a brief introduction of basic concepts of amorphous sy...

  8. Electronic Structure of Pure Selenium and Tellurium Chains and Selenium Rings and with Impurities

    Science.gov (United States)

    Maharjan, N. B.; Cho, Hwa-Suck; Scheicher, R. H.

    2005-03-01

    We have studied the electronic structures of pure chain-structured Selenium and Tellurium and with chalcogen impurities as well as ring-structured Selenium both pure and with Tellurium impurity atoms. The Hartree-Fock Cluster Theory procedure combined with many-body perturbation theory procedure has been used. The accuracy of the calculated electronic wave functions is tested by the investigation of ^77Se and ^125Te nuclear quadrupole interaction parameters. Good agreement is found with experiment for the pure systems. For the impurity systems, the agreement is reasonable but suggests the need for inclusion of more extensive relaxation around the impurity atoms. (*) Current Address: Dept. of Physics, Uppsala University, Sweden (**) Also: Dept. of Physics, University of Central Florida, Orlando, Florida

  9. The chronic autoimmune thyroiditis quality of life selenium trial (CATALYST)

    DEFF Research Database (Denmark)

    Winther, Kristian Hillert; Watt, Torquil; Bjørner, Jakob Bue;

    2014-01-01

    BACKGROUND: Patients with chronic autoimmune thyroiditis have impaired health-related quality of life. The thyroid gland has a high selenium concentration, and specific selenoprotein enzyme families are crucial to immune function, and catalyze thyroid hormone metabolism and redox processes...... in thyroid cells. Previous randomized controlled trials have found that selenium supplementation decreases thyroid-disease-specific antibody levels. We hypothesize that selenium might be beneficial in the treatment of chronic autoimmune thyroiditis. METHODS/DESIGN: The CATALYST trial is an investigator......-initiated randomized, blinded, multicentre clinical trial of selenium supplementation versus placebo in patients with chronic autoimmune thyroiditis. Inclusion criteria: age ≥18 years; serum thyroid peroxidase antibody level ≥100 IU/ml within the previous 12 months; treatment with levothyroxine and written informed...

  10. Selenium in aquatic habitats at Imperial National Wildlife Refuge

    Data.gov (United States)

    US Fish and Wildlife Service, Department of the Interior — During 1991 and 1992, selenium levels were studied in aquatic communities at Imperial National Wildlife Refuge on the lower Colorado River. Composite samples of...

  11. Union Slough National Wildlife Refuge, Iowa: Avian selenium study

    Data.gov (United States)

    US Fish and Wildlife Service, Department of the Interior — In 2006 and 2007, we tested selenium concentrations in the eggs and nestling carcasses of tree swallows attracted to artificial nest boxes installed around Union...

  12. Selenium content of milk and milk products of Turkey. II.

    Science.gov (United States)

    Yanardağ, R; Orak, H

    1999-04-01

    Selenium content of 1028 milk and milk products of Turkey are presented in this study. The selenium content of human milk (colostrum, transitional, and mature milk), various kinds of milk [cow, sheep, goat, buffalo, paper boxes (3%, 1.5%, 0.012% fat), bottled milk, condensed milk (10% fat), mineral added milk (1.6%), and banana, strawberry, and chocolate milk] and milk products (kefir, yogurt, Ayran, various cheese, coffee cream, ice cream, butter, margarine, milk powder, and fruit yogurt) in Turkey were determined by a spectrofluorometric method. The selenium levels of cow milks collected from 57 cities in Turkey were also determined. Selenium levels in cow milk varied with geographical location in Turkey and were found to be lowest for Van and highest for Aksaray. The results [milk (cow, sheep, goat, buffalo and human) and milks products] were compared with literature data from different countries.

  13. Selenium and lung cancer: a systematic review and meta analysis.

    Directory of Open Access Journals (Sweden)

    Heidi Fritz

    Full Text Available BACKGROUND: Selenium is a natural health product widely used in the treatment and prevention of lung cancers, but large chemoprevention trials have yielded conflicting results. We conducted a systematic review of selenium for lung cancers, and assessed potential interactions with conventional therapies. METHODS AND FINDINGS: Two independent reviewers searched six databases from inception to March 2009 for evidence pertaining to the safety and efficacy of selenium for lung cancers. Pubmed and EMBASE were searched to October 2009 for evidence on interactions with chemo- or radiation-therapy. In the efficacy analysis there were nine reports of five RCTs and two biomarker-based studies, 29 reports of 26 observational studies, and 41 preclinical studies. Fifteen human studies, one case report, and 36 preclinical studies were included in the interactions analysis. Based on available evidence, there appears to be a different chemopreventive effect dependent on baseline selenium status, such that selenium supplementation may reduce risk of lung cancers in populations with lower baseline selenium status (serum<106 ng/mL, but increase risk of lung cancers in those with higher selenium (≥ 121.6 ng/mL. Pooling data from two trials yielded no impact to odds of lung cancer, OR 0.93 (95% confidence interval 0.61-1.43; other cancers that were the primary endpoints of these trials, OR 1.51 (95%CI 0.70-3.24; and all-cause-death, OR 0.93 (95%CI 0.79-1.10. In the treatment of lung cancers, selenium may reduce cisplatin-induced nephrotoxicity and side effects associated with radiation therapy. CONCLUSIONS: Selenium may be effective for lung cancer prevention among individuals with lower selenium status, but at present should not be used as a general strategy for lung cancer prevention. Although promising, more evidence on the ability of selenium to reduce cisplatin and radiation therapy toxicity is required to ensure that therapeutic efficacy is maintained before

  14. Selenium transformation in coal mine spoils: Its environmental impact assessment

    Energy Technology Data Exchange (ETDEWEB)

    Harness, J.; Atalay, A.; Koll, K.J.; Zhang, H.; Maggon, D.

    1991-12-31

    The objective of this program was to conduct an environmental impact assessment study for selenium from coal mine spoils. The use of in-situ lysimetry to predict selenium speciation, transformation, and mobility under natural conditions was evaluated. The scope of the study was to construct and test field-scale lysimeter and laboratory mini-column to assess mobility and speciation of selenium in coal mine overburden and soil systems; to conduct soil and groundwater sampling throughout the state of Oklahoma for an overall environmental impact assessment of selenium; and to conduct an in-depth literature review on the solubility, speciation, mobility, and toxicity of selenium from various sources. Groundwater and surface soil samples were also collected from each county in Oklahoma. Data collected from the lysimeter study indicated that selenium in the overburden of the abandoned mine site was mainly found in the selenite form. The amount of selenite found was too low and immobile to be of concern to the environment. The spoil had equilibrated long enough (over 50 years) that most of the soluble forms of selenium have already been lost. Examination of the overburden indicated the presence of pyrite crystals that precipitated over time. The laboratory mini-column study indicated that selenite is quite immobile and remained on the overburden material even after leaching with dilute acid. Data from groundwater samples indicated that based on the current permissible level for selenium in groundwater (0.01 mg Se/L), Oklahoma groundwater is widely contaminated with the element. However, according to the new regulation (0.05 mg Se/L), which is to be promulgated in 1992, only 9 of the 77 counties in the state exceed the limit.

  15. Selenium toxicity: cause and effects in aquatic birds.

    Science.gov (United States)

    Spallholz, Julian E; Hoffman, David J

    2002-04-01

    There are several manners in which selenium may express its toxicity: (1) an important mechanism appears to involve the formation of CH(3)Se(minus sign) which either enters a redox cycle and generates superoxide and oxidative stress, or forms free radicals that bind to and inhibit important enzymes and proteins. (2) Excess selenium as selenocysteine results in inhibition of selenium methylation metabolism. As a consequence, concentrations of hydrogen selenide, an intermediate metabolite, accumulate in animals and are hepatotoxic, possibly causing other selenium-related adverse effects. (3) It is also possible that the presence of excess selenium analogs of sulfur-containing enzymes and structural proteins play a role in avian teratogenesis. L-selenomethionine is the most likely major dietary form of selenium encountered by aquatic birds, with lesser amounts of L-selenocysteine ingested from aquatic animal foods. The literature is suggestive that L-selenomethionine is not any more toxic to adult birds than other animals. L-Selenomethionine accumulates in tissue protein of adult birds and in the protein of egg white as would be expected to occur in animals. There is no suggestion from the literature that the levels of L-selenomethionine that would be expected to accumulate in eggs in the absence of environmental concentration of selenium pose harm to the developing embryo. For several species of aquatic birds, levels of Se as selenomethionine in the egg above 3 ppm on a wet weight basis result in reduced hatchability and deformed embryos. The toxicity of L-selenomethionine injected directly into eggs is greater than that found from the entry of L-selenomethionine into the egg from the normal adult diet. This suggests that there is unusual if not abnormal metabolism of L-selenomethionine in the embryo not seen when L-selenomethionine is present in egg white protein where it likely serves as a source of selenium for glutathione peroxidase synthesis in the developing

  16. Selenium toxicity: cause and effects in aquatic birds

    Science.gov (United States)

    Spallholz, J.E.; Hoffman, D.J.

    2002-01-01

    There are several manners in which selenium may express its toxicity: (1) an important mechanism appears to involve the formation of CH3Se- which either enters a redox cycle and generates superoxide and oxidative stress, or forms free radicals that bind to and inhibit important enzymes and proteins. (2) Excess selenium as selenocysteine results in inhibition of selenium methylation metabolism. As a consequence, concentrations of hydrogen selenide, an intermediate metabolite, accumulate in animals and are hepatotoxic, possibly causing other selenium-related adverse effects. (3) It is also possible that the presence of excess selenium analogs of sulfur-containing enzymes and structural proteins play a role in avian teratogenesis. l-selenomethionine is the most likely major dietary form of selenium encountered by aquatic birds, with lesser amounts of l-selenocysteine ingested from aquatic animal foods. The literature is suggestive that l-selenomethionine is not any more toxic to adult birds than other animals. l-Selenomethionine accumulates in tissue protein of adult birds and in the protein of egg white as would be expected to occur in animals. There is no suggestion from the literature that the levels of l-selenomethionine that would be expected to accumulate in eggs in the absence of environmental concentration of selenium pose harm to the developing embryo. For several species of aquatic birds, levels of Se as selenomethionine in the egg above 3 ppm on a wet weight basis result in reduced hatchability and deformed embryos. The toxicity of l-selenomethionine injected directly into eggs is greater than that found from the entry of l-selenomethionine into the egg from the normal adult diet. This suggests that there is unusual if not abnormal metabolism of l-selenomethionine in the embryo not seen when l-selenomethionine is present in egg white protein where it likely serves as a source of selenium for glutathione peroxidase synthesis in the developing aquatic chick.

  17. The chronic autoimmune thyroiditis quality of life selenium trial (CATALYST)

    DEFF Research Database (Denmark)

    Winther, Kristian Hillert; Watt, Torquil; Bjørner, Jakob Bue;

    2014-01-01

    . Exclusion criteria: previous diagnosis of toxic nodular goitre, Graves' hyperthyroidism, postpartum thyroiditis, Graves' orbitopathy; previous antithyroid drug treatment, radioiodine therapy or thyroid surgery; immune-modulatory or other medication affecting thyroid function; pregnancy, planned pregnancy...... or breastfeeding; allergy towards any intervention or placebo component; intake of selenium supplementation >55 mug/day; inability to read or understand Danish or lack of informed consent. The trial will include 2 x 236 participants. The experimental intervention and control groups will receive 200 mug selenium...

  18. An accurate determination of the surface energy of solid selenium

    Science.gov (United States)

    Guisbiers, G.; Arscott, S.; Snyders, R.

    2012-12-01

    Selenium is currently a key element for developing nano and micro-technologies. Nevertheless, the surface energy of solid selenium (γSe) reported in the literature is still questionable. In this work, we have measured γSe = 0.291 ± 0.025 J/m2 at 293 K using the sessile drop technique with different probe liquids, namely ethylene glycol, de-ionized water, mercury, and gallium. This value is in excellent agreement with theoretical predictions.

  19. Selenium concentrations of selected medicinal and aromatic plants in Turkey.

    Science.gov (United States)

    Ozkutlu, Faruk; Sekeroglu, Nazim; Koca, Ufuk; Yazici, Gizem

    2011-10-01

    Recent scientific studies have proven the importance of trace elements on human health. The main food supplies are plants and animals, which are significant sources of these minerals. Studies on determining mineral compositions of herbs, spices and some other crops have increased all over the world. Published works revealed that spices, herbs and medicinal plants should be consumed to obtain beneficial trace elements. Selenium (Se), one of the most vital trace elements, has a significant role in human diet acting as a preventative agent against some serious illnesses. Despite numerous scientific works on mineral compositions of medicinal and aromatic plants, investigations of selenium content in these foods could not be successfully studied until recently due to the lack of suitable analytical methods for selenium analysis. Thus, publications on selenium concentrations of foods are recent. In this regard, selenium contents of some medicinal and aromatic plants commonly used as spices, herbal teas and traditional medicines in Turkey were studied in the present research. Selenium contents of the most used parts of these plants were analyzed by ICP-OES (Varian Vista-Pro, Australia). Of the analyzed 26 medicinal and aromatic plants, the highest Se concentration (1133 microg kg-1) was found in sweet basil (Ocimum basilicum L.) and the lowest in sumac (Rhus coriaria L.) fruits (11 microg kg(-1)).

  20. Lithium ion beam impact on selenium nanowires

    Science.gov (United States)

    Panchal, Suresh; Chauhan, R. P.

    2017-03-01

    This study is structured on Li3+ ion irradiation effect on the different properties of selenium (Se) nanowires (NW's) (80 nm). Template technique was employed for the synthesis of Se nanowires. Exploration of the effect of 10 MeV Li3+ ions on Se NW's was done for structural and electrical analysis with the help of characterization tools. X-ray diffraction revealed the variation in peak intensity only, with no peak shifting. The grain size and texture coefficients of various planes were also found to vary. Current-Voltage characteristics (IVC) show an increment in the conductivity up to a fluence of 1×1012 ions/cm2 and a decrease at the next two fluences. The effects of irradiation are presented in this paper and possible reasons for the variation in properties are also discussed in this study.

  1. Normal mode calculations of trigonal selenium

    DEFF Research Database (Denmark)

    Hansen, Flemming Yssing; McMurry, H. L.

    1980-01-01

    symmetry. The intrachain force field is projected from a valence type field including a bond stretch, angle bend, and dihedral torsion. With these coordinates we obtain the strong dispersion of the upper optic modes as observed by neutron scattering, where other models have failed and give flat bands......The phonon dispersion relations for trigonal selenium have been calculated on the basis of a short range potential field model. Electrostatic long range forces have not been included. The force field is defined in terms of symmetrized coordinates which reflect partly the symmetry of the space group....... In this way we have eliminated the ambiguity in the choice of valence coordinates, which has been a problem in previous models which used valence type interactions. Calculated sound velocities and elastic moduli are also given. The Journal of Chemical Physics is copyrighted by The American Institute...

  2. [Selenium and cancer: from prevention to treatment].

    Science.gov (United States)

    Brozmanová, J

    2011-01-01

    Selenium (Se) is an essential dietary component for all animals, including human beings, that is regarded as a protective agent against cancer. Although the mode of its anticancer action is not yet fully understood, several mechanisms, such as antioxidant protection through selenoenzymes, stimulation of DNA repair, and apoptosis in tumor prestages have all been proposed. Despite the unsupported results of the last "SELECT" trial, the cancer-preventing activity of Se has been demonstrated in a majority of epidemiological studies. Moreover, recent studies suggest that Se has a potential to be used not only in cancer prevention but also in cancer treatment, where in combination with other anticancer drugs or radiation it may increase the efficacy of cancer therapy. In combating cancer cells, Se acts as a prooxidant rather than an antioxidant, inducing apoptosis through the generation of oxidative stress. Thus, inorganic Se compounds, having high redox potency, represent a promising option in cancer therapy.

  3. The effect of dietary selenium source on embryonic development in Turkeys.

    Science.gov (United States)

    Stepińska, Monika; Mróz, Emilia; Jankowski, Jan

    2012-01-01

    The objective of this study was to determine the effect of dietary selenium source on the growth and development of turkey embryos, and egg hatchability. White broad-breasted BUT Big 6 turkeys (1800 females and 150 males) were placed under optimum management conditions. Turkey diets were supplemented with organic selenium, and in the other with inorganic selenium, in the amount of 0.3 ppm. Eggs intended for incubation and examination were collected in week 2, 10, 18 and 23 of the laying season. The average egg weight was higher (p selenium than in layers receiving inorganic selenium. The rate of yolk sac retraction was faster in embryos from the group fed a diet with inorganic selenium, and it reached 0.59 of the complete yolk sac on day 25 of incubation (p Selenium source had no effect on the hatching rates of fertilized eggs, which reached 79.61% and 79.84% in laying hens fed organic and inorganic selenium, respectively. In the flocks fed diets supplemented with organic selenium, dead embryos were more frequently characterized by problems with protein utilization (19.28%) and delayed pipping (10.83%). Embryo death rates at the first mortality peak were higher in layers fed inorganic selenium than in those receiving organic selenium (15% vs. 13.5%). The second embryo mortality peak occurred earlier (day 26) in laying hens fed inorganic selenium than in those fed organic selenium (day 28).

  4. Copper and selenium supplementation in the diet of Brangus steers on the nutritional characteristics of meat

    Directory of Open Access Journals (Sweden)

    Arlindo Saran Netto

    2013-01-01

    Full Text Available Twenty-eight Brangus cattle were used to determine the effect of copper and selenium supplementation on the carcass characteristics, fatty acid composition of the longissimus dorsi muscle and on the copper and selenium concentrations in the liver. The treatments were: no supplementation of copper or selenium; 2 mg Se/kg DM as sodium selenite; 40 mg Cu/kg DM as copper sulfate; and 2 mg Se/kg DM as sodium selenite and 40 mg Cu/kg DM as copper sulfate. The fat thickness, rib eye area and fatty acid composition of the longissimus dorsi muscle were not affected by treatments. There was no effect on carcass yield and cooling loss with the supplementation of copper, selenium or selenium × copper in the levels studied. For the ether extract concentration in the longissimus dorsi muscle, no differences were found according to the treatments with selenium, copper or selenium × copper. The treatments with selenium and selenium × copper showed higher selenium concentrations in the liver than the control and copper treatments. For the copper concentration in the liver, the copper and selenium × copper treatments showed higher values than the control and selenium treatments. Despite the little effect on the meat composition, the results of this experiment demonstrate no interaction between selenium and copper in the levels studied.

  5. Selenium Uptake and Volatilization by Marine Algae

    Science.gov (United States)

    Luxem, Katja E.; Vriens, Bas; Wagner, Bettina; Behra, Renata; Winkel, Lenny H. E.

    2015-04-01

    Selenium (Se) is an essential trace nutrient for humans. An estimated one half to one billion people worldwide suffer from Se deficiency, which is due to low concentrations and bioavailability of Se in soils where crops are grown. It has been hypothesized that more than half of the atmospheric Se deposition to soils is derived from the marine system, where microorganisms methylate and volatilize Se. Based on model results from the late 1980s, the atmospheric flux of these biogenic volatile Se compounds is around 9 Gt/year, with two thirds coming from the marine biosphere. Algae, fungi, and bacteria are known to methylate Se. Although algal Se uptake, metabolism, and methylation influence the speciation and bioavailability of Se in the oceans, these processes have not been quantified under environmentally relevant conditions and are likely to differ among organisms. Therefore, we are investigating the uptake and methylation of the two main inorganic Se species (selenate and selenite) by three globally relevant microalgae: Phaeocystis globosa, the coccolithophorid Emiliania huxleyi, and the diatom Thalassiosira oceanica. Selenium uptake and methylation were quantified in a batch experiment, where parallel gas-tight microcosms in a climate chamber were coupled to a gas-trapping system. For E. huxleyi, selenite uptake was strongly dependent on aqueous phosphate concentrations, which agrees with prior evidence that selenite uptake by phosphate transporters is a significant Se source for marine algae. Selenate uptake was much lower than selenite uptake. The most important volatile Se compounds produced were dimethyl selenide, dimethyl diselenide, and dimethyl selenyl sulfide. Production rates of volatile Se species were larger with increasing intracellular Se concentration and in the decline phase of the alga. Similar experiments are being carried out with P. globosa and T. oceanica. Our results indicate that marine algae are important for the global cycling of Se

  6. Determinants of selenium status in healthy adults

    Directory of Open Access Journals (Sweden)

    Hoeg Antonia

    2011-07-01

    Full Text Available Abstract Background Selenium (Se status in non-deficient subjects is typically assessed by the Se contents of plasma/serum. That pool comprises two functional, specific selenoprotein components and at least one non-functional, non-specific components which respond differently to changes in Se intake. A more informative means of characterizing Se status in non-deficient individuals is needed. Methods Multiple biomarkers of Se status (plasma Se, serum selenoprotein P [SEPP1], plasma glutathione peroxidase activity [GPX3], buccal cell Se, urinary Se were evaluated in relation to selenoprotein genotypes (GPX1, GPX3, SEPP1, SEP15, dietary Se intake, and parameters of single-carbon metabolism in a cohort of healthy, non-Se-deficient men (n = 106 and women (n = 155. Conclusions Plasma Se concentration was 142.0 ± 23.5 ng/ml, with GPX3 and serum-derived SEPP1 calculated to comprise 20% and 34%, respectively, of that total. The balance, comprised of non-specific components, accounted for virtually all of the interindividual variation in total plasma Se. Buccal cell Se was associated with age and plasma homocysteine (hCys, but not plasma Se. SEPP1 showed a quadratic relationship with body mass index, peaking at BMI 25-30. Urinary Se was greater in women than men, and was associated with metabolic body weight (kg0.75, plasma folate, vitamin B12 and hCys (negatively. One GPX1 genotype (679T/T was associated with significantly lower plasma Se levels than other allelic variants. Selenium intake, estimated from food frequency questionnaires, did not predict Se status as indicated by any biomarker. These results show that genotype, methyl-group status and BMI contribute to variation in Se biomarkers in Se-adequate individuals.

  7. Comparison of selenium distribution in mice organs after the supplementation with inorganic and organic selenium compound selenosemicarbazide.

    Science.gov (United States)

    Musik, Irena; Kozioł-Montewka, Maria; Toś-Luty, Sabina; Donica, Helena; Pasternak, Kazimierz; Wawrzycki, Sławomir

    2002-01-01

    Studies on selenium organ content and its function in living organisms just like studies on other elements provide interesting results although their interpretation is not always clear. The aim of our study was to determine the concentration and distribution of selenium in several organs and tissues in mice after supplementation with our newly synthesized organic compound of selenium selenosemicarbazide (4-o-tolyl-selenosemicarbazide of o-chlorobenzoic acid) as compared to the effects of the supplementation with inorganic compounds. SWISS mice were fed with both types of compounds at the dose of 10(-3) g Se per kg for the period of 10 days. The concentrations of selenium in brains of mice treated with selenocarbazide and sodium selenite were higher than in controls (38.04 micrograms g-1 and 32.00 micrograms g-1 vs. 26.18 micrograms g-1). There was a statistically significant increase in the selenium contents in lungs after supplementation with selenosemicarbazide and sodium selenite (11.81 micrograms g-1 and 6.79 micrograms g-1 vs. 1.75 micrograms g-1 in controls). We found a statistically insignificant increase in selenium contents in intercostal muscles after supplementation with inorganic selenium compounds and a statistically significant increase after the supplementation with selenosemicarbazide (10.13 micrograms g-1; 14.21 micrograms g-1 and 28.84 micrograms g-1, respectively). Our investigations lead to a conclusion that 4-o-tolyl-seleno-semicarbazide of o-chlorobenzoic acid, an organic selenium compound may be more easily absorbed than inorganic sodium IV selenite.

  8. Effect of foliar application of selenium on the antioxidant activity of aqueous and ethanolic extracts of selenium-enriched rice.

    Science.gov (United States)

    Xu, Juan; Hu, Qiuhui

    2004-03-24

    Selenium fertilizer was foliar applied to determine the effects of antioxidant activity of selenium-enriched rice assessed by alpha,alpha-diphenyl-beta-picylhydrazyl (DPPH) radical scavenging and the ferric thiocyanate (FTC) method. Results showed that selenium concentration in rice was significantly enhanced dose dependently. Aqueous or ethanolic extracts of rice displayed significantly higher antioxidant activity against lipid peroxidation. The activities of aqueous extracts were significantly higher than those of ethanolic extracts and increased with the increasing selenium concentration in rice. The DPPH assay showed that the kinetic behaviors of aqueous extracts were complex and slow, while ethanolic extracts reacted quickly with DPPH radical. Aqueous extracts of rice exhibited higher antiradical efficiencies than ethanolic extracts, and rice (1.275 mg Se kg(-)(1)) presented the lowest EC(50) values of 533.46 +/- 0.58 microg mL(-)(1). As compared to rice extracts, all of the reference antioxidants showed more than 4-fold antiradical efficiencies than rice extracts. This radical scavenging activity was significantly correlated with selenium concentrations in rice (R = 0.862, p < 0.05), while ethanolic extracts were inversely correlated with selenium concentration in rice.

  9. Selenium and vitamin E for prostate cancer: post-SELECT (Selenium and Vitamin E Cancer Prevention Trial) status.

    Science.gov (United States)

    Ledesma, Mark C; Jung-Hynes, Brittney; Schmit, Travis L; Kumar, Raj; Mukhtar, Hasan; Ahmad, Nihal

    2011-01-01

    Various formulations of selenium and vitamin E, both essential human dietary components, have been shown to possess a therapeutic and preventive effect against prostate cancer. Fortuitous results of clinical trials also implied a risk-reduction effect of selenium and vitamin E supplements. The Selenium and Vitamin E Cancer Prevention Trial (SELECT), using oral selenium and vitamin E supplementation in disease-free volunteers, was designed to test a prostate cancer chemoprevention hypothesis. SELECT was terminated early because of both safety concerns and negative data for the formulations and doses given. Here, we review and discuss the studies done before and since the inception of SELECT, as well as the parameters of the trial itself. We believe that there is a lack of appropriate in vivo preclinical studies on selenium and vitamin E despite many promising in vitro studies on these agents. It seems that the most effective doses and formulations of these agents for prostate cancer chemoprevention have yet to be tested. Also, improved understanding of selenium and vitamin E biology may facilitate the discovery of these doses and formulations.

  10. Loss of Selenium-Binding Protein 1 Decreases Sensitivity to Clastogens and Intracellular Selenium Content in HeLa Cells

    Science.gov (United States)

    Zhao, Changhui; Zeng, Huawei; Wu, Ryan T. Y.; Cheng, Wen-Hsing

    2016-01-01

    Selenium-binding protein 1 (SBP1) is not a selenoprotein but structurally binds selenium. Loss of SBP1 during carcinogenesis usually predicts poor prognosis. Because genome instability is a hallmark of cancer, we hypothesize that SBP1 sequesters cellular selenium and sensitizes cancer cells to DNA-damaging agents. To test this hypothesis, we knocked down SBP1 expression in HeLa cervical cancer cells by employing a short hairpin RNA (shRNA) approach. Reduced sensitivity to hydrogen peroxide, paraquat and camptothecin, reactive oxygen species content, and intracellular retention of selenium after selenomethionine treatment were observed in SBP1 shRNA HeLa cells. Results from Western analyses showed that treatment of HeLa cells with selenomethionine resulted in increased SBP1 protein expression in a dose-dependent manner. Knockdown of SBP1 rendered HeLa cells increased expression of glutathione peroxidase-1 but not glutathione peroxidase-4 protein levels and accelerated migration from a wound. Altogether, SBP1 retains supplemental selenium and sensitizes HeLa cancer cells to clastogens, suggesting a new cancer treatment strategy by sequestering selenium through SBP1. PMID:27404728

  11. Corrosion resistant amorphous metals and methods of forming corrosion resistant amorphous metals

    Science.gov (United States)

    Farmer, Joseph C.; Wong, Frank M.G.; Haslam, Jeffery J.; Yang, Nancy; Lavernia, Enrique J.; Blue, Craig A.; Graeve, Olivia A.; Bayles, Robert; Perepezko, John H.; Kaufman, Larry; Schoenung, Julie; Ajdelsztajn, Leo

    2014-07-15

    A system for coating a surface comprises providing a source of amorphous metal, providing ceramic particles, and applying the amorphous metal and the ceramic particles to the surface by a spray. The coating comprises a composite material made of amorphous metal that contains one or more of the following elements in the specified range of composition: yttrium (.gtoreq.1 atomic %), chromium (14 to 18 atomic %), molybdenum (.gtoreq.7 atomic %), tungsten (.gtoreq.1 atomic %), boron (.ltoreq.5 atomic %), or carbon (.gtoreq.4 atomic %).

  12. Polymer-support Selenium-induced Electrophilic Cyclization: Solid-phase Synthesis of Flavonoids

    Institute of Scientific and Technical Information of China (English)

    Jian CAO; E TANG; Xuan HUANG; Lu Ling WU; Xian HUANG

    2006-01-01

    The Lewis acid mediated polystyrene supported selenium induced intramolecular cyclization of chalcones and oxidative cleavage of selenium resins gave the corresponding flavonoids in good yields and purities have been reported.

  13. Biological and chemical investigation of Allium cepa L. response to selenium inorganic compounds.

    Science.gov (United States)

    Michalska-Kacymirow, M; Kurek, E; Smolis, A; Wierzbicka, M; Bulska, E

    2014-06-01

    The aim of this study was to evaluate the biological and chemical response of Allium cepa L. exposed to inorganic selenium compounds. Besides the investigation of the total content of selenium as well as its chemical speciation, the Allium test was used to evaluate the growth of onion roots and mitotic activity in the roots' meristem. The total content of selenium was determined by inductively coupled plasma mass spectrometry (ICP MS). High-performance liquid chromatography (HPLC), coupled to ICP MS, was used for the selenium chemical speciation. Results indicated that A. cepa plants are able to biotransform inorganic selenium compounds into their organic derivatives, e.g., Se-methylselenocysteine from the Se(IV) inorganic precursor. Although the differences in the biotransformation of selenium are due mainly to the oxidation state of selenium, the experiment has also shown a fine effect of counter ions (H(+), Na(+), NH4 (+)) on the response of plants and on the specific metabolism of selenium.

  14. Hazard assessment of selenium contamination at Benton Lake National Wildlife Refuge

    Data.gov (United States)

    US Fish and Wildlife Service, Department of the Interior — This report summarizes a study done to assess selenium levels on Benton Lake NWR. Because selenium is not evenly distributed across wetland units, sampling in 2006...

  15. Final report on biogeochemical cycling of selenium in Benton Lake, Montana

    Data.gov (United States)

    US Fish and Wildlife Service, Department of the Interior — The biogeochemical cycling of selenium in Benton Lake National Wildlife Refuge, west-central Montana was very complicated. Selenium accumulation in sediment was a...

  16. Update to hazard assessment of selenium contamination at Benton Lake National Wildlife Refuge

    Data.gov (United States)

    US Fish and Wildlife Service, Department of the Interior — The levels of selenium in all trophic levels in Unit 1 on the refuge continue to be a concern. The mean concentration of selenium in water, sediment,...

  17. Vitamin E, Selenium Supplements Won't Curb Men's Dementia Risk

    Science.gov (United States)

    ... page: https://medlineplus.gov/news/fullstory_164174.html Vitamin E, Selenium Supplements Won't Curb Men's Dementia ... 20, 2017 (HealthDay News) -- A daily dose of vitamin E or selenium supplements won't keep dementia ...

  18. Update to hazard assessment of selenium contamination at Benton Lake National Wildlife Refuge

    Data.gov (United States)

    US Fish and Wildlife Service, Department of the Interior — This report summarizes a study done to assess selenium levels on Benton Lake NWR. Water was sampled for dissolved selenium in Lake Creek at the point where it enters...

  19. Tracer Diffusion Mechanism in Amorphous Solids

    Directory of Open Access Journals (Sweden)

    P. K. Hung

    2011-01-01

    Full Text Available Tracer diffusion in amorphous solid is studied by mean of nB-bubble statistic. The nB-bubble is defined as a group of atoms around a spherical void and large bubble that represents a structural defect which could be eliminated under thermal annealing. It was found that amorphous alloys such as CoxB100−x (x=90, 81.5 and 70 and Fe80P20 suffer from a large number of vacancy bubbles which function like diffusion vehicle. The concentration of vacancy bubble weakly depends on temperature, but essentially on the relaxation degree of considered sample. The diffusion coefficient estimated for proposed mechanism via vacancy bubbles is in a reasonable agreement with experiment for actual amorphous alloys. The relaxation effect for tracer diffusion in amorphous alloys is interpreted by the elimination of vacancy bubbles under thermal annealing.

  20. Theoretical Considerations in Developing Amorphous Solid Dispersions

    DEFF Research Database (Denmark)

    Laitinen, Riikka; Priemel, Petra Alexandra; Surwase, Sachin;

    2014-01-01

    Before pursuing the laborious route of amorphous solid dispersion formulation and development, which is the topic of many of the subsequent chapters in this book, the formulation scientist would benefit from a priori knowledge whether the amorphous route is a viable one for a given drug and how...... to their glass-forming ability and glass stability. In the main parts of this chapter, we review theoretical approaches to determine amorphous drug polymer miscibility and crystalline drug polymer solubility, as a prerequisite to develop amorphous solid dispersions (glass solutions)....... much solubility improvement, and hence increase in bioavailability, can be expected, and what forms of solid dispersion have been developed in the past. In this chapter, we therefore initially define the various forms of solid dispersions, and then go on to discuss properties of pure drugs with respect...

  1. Surface Acidity of Amorphous Aluminum Hydroxide

    Institute of Scientific and Technical Information of China (English)

    K. FUKUSHI; K. TSUKIMURA; H. YAMADA

    2006-01-01

    The surface acidity of synthetic amorphous Al hydroxide was determined by acid/base titration with several complementary methods including solution analyses of the reacted solutions and XRD characterization of the reacted solids. The synthetic specimen was characterized to be the amorphous material showing four broad peaks in XRD pattern. XRD analyses of reacted solids after the titration experiments showed that amorphous Al hydroxide rapidly transformed to crystalline bayerite at the alkaline condition (pH>10). The solution analyses after and during the titration experiments showed that the solubility of amorphous aluminum hydroxide, Ksp =aAl3+/a3H+,was 1010.3,The amount of consumption of added acid or base during the titration experiment was attributed to both the protonation/deprotonation of dissolved Al species and surface hydroxyl group. The surface acidity constants, surface hydroxyl density and specific surface area were estimated by FITEQL 4.0.

  2. A Magnetic Sensor with Amorphous Wire

    Directory of Open Access Journals (Sweden)

    Dongfeng He

    2014-06-01

    Full Text Available Using a FeCoSiB amorphous wire and a coil wrapped around it, we have developed a sensitive magnetic sensor. When a 5 mm long amorphous wire with the diameter of 0.1 mm was used, the magnetic field noise spectrum of the sensor was about 30 pT/ÖHz above 30 Hz. To show the sensitivity and the spatial resolution, the magnetic field of a thousand Japanese yen was scanned with the magnetic sensor.

  3. Amorphous Carbon-Boron Nitride Nanotube Hybrids

    Science.gov (United States)

    Kim, Jae Woo (Inventor); Siochi, Emilie J. (Inventor); Wise, Kristopher E. (Inventor); Lin, Yi (Inventor); Connell, John (Inventor)

    2016-01-01

    A method for joining or repairing boron nitride nanotubes (BNNTs). In joining BNNTs, the nanotube structure is modified with amorphous carbon deposited by controlled electron beam irradiation to form well bonded hybrid a-C/BNNT structures. In repairing BNNTs, the damaged site of the nanotube structure is modified with amorphous carbon deposited by controlled electron beam irradiation to form well bonded hybrid a-C/BNNT structures at the damage site.

  4. A Magnetic Sensor with Amorphous Wire

    OpenAIRE

    Dongfeng He; Mitsuharu Shiwa

    2014-01-01

    Using a FeCoSiB amorphous wire and a coil wrapped around it, we have developed a sensitive magnetic sensor. When a 5 mm long amorphous wire with the diameter of 0.1 mm was used, the magnetic field noise spectrum of the sensor was about 30 pT/ÖHz above 30 Hz. To show the sensitivity and the spatial resolution, the magnetic field of a thousand Japanese yen was scanned with the magnetic sensor.

  5. Emerging trends in the stabilization of amorphous drugs

    DEFF Research Database (Denmark)

    Laitinen, Riikka; Löbmann, Korbinian; Strachan, Clare J.;

    2013-01-01

    water-soluble drugs can be increased by the formation of stabilized amorphous forms. Currently, formulation as solid polymer dispersions is the preferred method to enhance drug dissolution and to stabilize the amorphous form of a drug. The purpose of this review is to highlight emerging alternative...... methods to amorphous polymer dispersions for stabilizing the amorphous form of drugs. First, an overview of the properties and stabilization mechanisms of amorphous forms is provided. Subsequently, formulation approaches such as the preparation of co-amorphous small-molecule mixtures and the use...... of mesoporous silicon and silica-based carriers are presented as potential means to increase the stability of amorphous pharmaceuticals....

  6. Selenium Concentrations in Irrigation Drain Inflows to the Salton Sea, California, October 2006 and January 2007

    Science.gov (United States)

    May, Thomas W.; Walther, Mike W.; Brumbaugh, William G.

    2007-01-01

    This report presents raw data on selenium concentrations in samples of water, sediment, detritus, and selected food-chain matrices collected from selected agricultural drains in the southern portion of the Salton Sea during October 2006 and January 2007. Total selenium and selenium species were determined in water samples, whereas total selenium was determined in sediment, detritus, algae, plankton, midge larvae (Family Chironomidae), and two fish species (western mosquitofish, Gambusia affinis, and sailfin molly, Poecilia latipinna).

  7. Selenium toxicity in breeding ring-necked pheasants (Phasianus colchicus).

    Science.gov (United States)

    Latshaw, J D; Morishita, T Y; Sarver, C F; Thilsted, J

    2004-12-01

    A flock of breeding ring-necked pheasants received feed with a high selenium content. Within 4 days of eating the toxic feed, the rate of egg production began to decrease, and bird aggression increased. Approximately 12% of the hens died within a week. Necropsy of the hens revealed colorless fluid around the heart and a friable, but otherwise normal, liver. The rapid onset of the problem and signs noted at necropsy suggested toxicosis. Based on analysis, the feed contained 9.3 ppm of selenium. Selenium toxicity was consistent with the histologic diagnosis of degenerative cardiomyopathy, vacuolar degeneration of hepatocytes, and centrilobular hepatic necrosis. After 8 days, the toxic feed was removed and replaced with fresh feed. Egg production, which had dropped to 50%, returned to normal within 10 days of feed replacement. Hatchability of eggs laid from days 8 to 14 after delivery of the toxic feed was 35%. Approximately 10% of the chicks that hatched had deformed beaks and abnormal eyes. Many of the chicks that died in the shell had deformities, bringing the total to more than 50% of all embryos that developed. The selenium content of eggs that had no embryonic development was 2.05 ppm. Hatchability of eggs laid from days 21 to 28 after the toxic feed was delivered was almost 80%, which was slightly lower than normal. The selenium content of these eggs was 0.30 ppm. These results show the rapid onset and correction of selenium toxicity and suggest that specific embryologic defects are diagnostic for selenium toxicity.

  8. Selenium and the thyroid: A close-knit connection

    Directory of Open Access Journals (Sweden)

    Ashok K Bhuyan

    2012-01-01

    Full Text Available Introduction: In areas with severe selenium deficiency higher incidence of thyroiditis has been reported due to a decreased activity of selenium-dependent glutathione peroxidase enzyme within thyroid cells. Aims and Objective: To study the effect of selenium supplementation in patients with autoimmune thyroid disease. Materials and Methods: This is a blinded placebo-controlled prospective study done in 60 patients with autoimmune thyroid disease (as defined by an anti-thyroid peroxidase antibody (TPOAb level more than 150 IU/ml irrespective of the baseline thyroid status. Patients with overt hyperthyroidism who are on antithyroid drugs, patients on any other medication, which may alter the immunity status of the patients, and pregnant patients were excluded from the study. Patients were randomized into two age and TPOAb-matched groups; 30 patients received 200 μg of sodium selenite/day, orally, for 3 months, and 30 patients received placebo. All hypothyroid patients were given l-thyroxine replacement. Results: Of 30 patients in the selenium treated group, 6 patients were overtly hypothyroid, 15 were subclinical hypothyroid, 6 were euthyroid, and 3 were subclinical hyperthyroid. The mean TPOAb concentration decreased significantly by 49.5% (P < 0.013 in the selenium treated group versus 10.1% (P < 0.95 in the placebo-treated group. Conclusion: Selenium substitution has a significant impact on inflammatory activity in thyroid-specific autoimmune disease. It would be of interest to determine whether early treatment with selenium in patients with newly developed autoimmune thyroiditis may delay or even prevent the natural course of these diseases.

  9. Intravenous Selenium Modulates L-Arginine-Induced Experimental Acute Pancreatitis

    Directory of Open Access Journals (Sweden)

    Jonathan Hardman

    2005-09-01

    Full Text Available Context Oxidative stress is understood to have a critical role in the development of acinar injury in experimental acute pancreatitis. We have previously demonstrated that compound multiple antioxidant therapy ameliorates end-organ damage in the intra-peritoneal L-arginine rat model. As the principal co-factor for glutathione, selenium is a key constituent of multiple antioxidant preparations. Objective The intention of this study was to investigate the effect of selenium on pancreatic and remote organ injury in a wellvalidated experimental model of acute pancreatitis. Methods Male Sprague-Dawley rats were randomly allocated to one of 3 groups (n=5/group and sacrificed at 72 hours. Acute pancreatitis was induced by 250 mg per 100 g body weight of 20% L-arginine hydrochloride in 0.15 mol/L sodium chloride. Group allocations were: Group 1, control; Group 2, acute pancreatitis; Group 3, selenium. Main outcome measures Serum amylase, anti-oxidant levels, bronchoalveolar lavage protein, lung myeloperoxidase activity, and histological assessment of pancreatic injury. Results L-arginine induced acute pancreatitis characterised by oedema, neutrophil infiltration, acinar cell degranulation and elevated serum amylase. Selenium treatment was associated with reduced pancreatic oedema and inflammatory cell infiltration. Acinar degranulation and dilatation were completely absent. A reduction in bronchoalveolar lavage protein content was also demonstrated. Conclusion Intravenous selenium given 24 hours after induction of experimental acute pancreatitis was associated with a reduction in the histological stigmata of pancreatic injury and a dramatic reduction in broncho-alveolar lavage protein content. Serum selenium fell during the course of experimental acute pancreatitis and this effect was not reversed by exogenous selenium supplementation.

  10. Concentrations of boron, molybdenum, and selenium in chinook salmon

    Science.gov (United States)

    Hamilton, Steven J.; Wiedmeyer, Raymond H.

    1990-01-01

    The concentrations of boron, molybdenum, and selenium in young chinook salmon Oncorhynchus tshawytscha were determined in three partial life cycle chronic toxicity studies. In each study, fish were exposed to a mixture of boron, molybdenum, selenate, and selenite in the proportions found in subsurface agricultural drainage water in the basin of the San Joaquin Valley, California. Tests were conducted in well water and in site-specific fresh and brackish waters. No boron or molybdenum was detected in fish exposed to concentrations as high as 6,046 μg boron/L and 193 μg molybdenum/L for 90 d in well water or fresh water; however, whole-body concentrations of selenium increased with increasing exposure concentrations in well water and fresh water, but not in brackish water. Concentrations of selenium in chinook salmon were strongly correlated with reduced survival and growth of fish in well water and with reduced survival in a 15-d seawater challenge test of fish from fresh water. Concentrations of selenium in fish seemed to reach a steady state after 60 d of exposure in well water or fresh water. Fish in brackish water had only background concentrations of selenium after 60 d of exposure, and no effects on survival and growth in brackish water or on survival in a 10-d seawater challenge test were exhibited. This lack of effect in brackish water was attributed to initiation of the study with advanced fry, which were apparently better able to metabolize the trace element mixture than were the younger fish used in studies with well water and fresh water. In all three experimental waters, concentration factors (whole-body concentration/waterborne concentration) for selenium decreased with increasing exposure concentrations, suggesting decreased uptake or increased excretion, or both, of selenium at the higher concentrations.

  11. Treating chronic arsenic toxicity with high selenium lentil diets

    Energy Technology Data Exchange (ETDEWEB)

    Sah, Shweta [Department of Ecosystem and Public Health, Faculty of Medicine, University of Calgary, Calgary, AB T2N 4Z6 (Canada); Vandenberg, Albert [Department of Plant Sciences, University of Saskatchewan, Saskatoon, SK S7N 5A8 (Canada); Smits, Judit, E-mail: judit.smits@ucalgary.ca [Department of Ecosystem and Public Health, Faculty of Veterinary Medicine, University of Calgary, Calgary, AB T2N 4Z6 (Canada)

    2013-10-01

    Arsenic (As) toxicity causes serious health problems in humans, especially in the Indo-Gangetic plains and mountainous areas of China. Selenium (Se), an essential micronutrient is a potential mitigator of As toxicity due to its antioxidant and antagonistic properties. Selenium is seriously deficient in soils world-wide but is present at high, yet non-toxic levels in the great plains of North America. We evaluate the potential of dietary Se in counteracting chronic As toxicity in rats through serum biochemistry, blood glutathione levels, immunotoxicity (antibody response), liver peroxidative stress, thyroid response and As levels in tissues and excreta. To achieve this, we compare diets based on high-Se Saskatchewan (SK) lentils versus low-Se lentils from United States. Rats drank control (0 ppm As) or As (40 ppm As) water while consuming SK lentils (0.3 ppm Se) or northwestern USA lentils (< 0.01 ppm Se) diets for 14 weeks. Rats on high Se diets had higher glutathione levels regardless of As exposure, recovered antibody responses in As-exposed group, higher fecal and urinary As excretion and lower renal As residues. Selenium deficiency caused greater hepatic peroxidative damage in the As exposed animals. Thyroid hormones, triiodothyronine (T3) and thyroxine (T4), were not different. After 14 weeks of As exposure, health indicators in rats improved in response to the high Se lentil diets. Our results indicate that high Se lentils have a potential to mitigate As toxicity in laboratory mammals, which we hope will translate into benefits for As exposed humans. - Highlights: • We reduce chronic arsenic toxicity in rats with a whole food solution. • High selenium lentils decrease liver damage and increase blood glutathione levels. • High selenium lentil diets increase urinary and fecal arsenic excretion. • High selenium lentil diets decrease arsenic levels in kidney, the storage organ. • High selenium lentil diets reverse arsenic suppression of the B cell

  12. Thermal transport in amorphous materials: a review

    Science.gov (United States)

    Wingert, Matthew C.; Zheng, Jianlin; Kwon, Soonshin; Chen, Renkun

    2016-11-01

    Thermal transport plays a crucial role in performance and reliability of semiconductor electronic devices, where heat is mainly carried by phonons. Phonon transport in crystalline semiconductor materials, such as Si, Ge, GaAs, GaN, etc, has been extensively studied over the past two decades. In fact, study of phonon physics in crystalline semiconductor materials in both bulk and nanostructure forms has been the cornerstone of the emerging field of ‘nanoscale heat transfer’. On the contrary, thermal properties of amorphous materials have been relatively less explored. Recently, however, a growing number of studies have re-examined the thermal properties of amorphous semiconductors, such as amorphous Si. These studies, which included both computational and experimental work, have revealed that phonon transport in amorphous materials is perhaps more complicated than previously thought. For instance, depending on the type of amorphous materials, thermal transport occurs via three types of vibrations: propagons, diffusons, and locons, corresponding to the propagating, diffusion, and localized modes, respectively. The relative contribution of each of these modes dictates the thermal conductivity of the material, including its magnitude and its dependence on sample size and temperature. In this article, we will review the fundamental principles and recent development regarding thermal transport in amorphous semiconductors.

  13. Sorption of selenium(IV) and selenium(VI) onto magnetite

    Energy Technology Data Exchange (ETDEWEB)

    Martinez, M. [Department Chemical Engineering (ETSEIB-UPC), Av. Diagonal 647, 08028 Barcelona (Spain); Gimenez, J. [Department Chemical Engineering (ETSEIB-UPC), Av. Diagonal 647, 08028 Barcelona (Spain)]. E-mail: francisco.javier.gimenez@upc.edu; Pablo, J. de [Department Chemical Engineering (ETSEIB-UPC), Av. Diagonal 647, 08028 Barcelona (Spain); CTM-UPC, Avda. Bases de Manresa, 1. 08240 Manresa (Spain); Rovira, M. [CTM-UPC, Avda. Bases de Manresa, 1. 08240 Manresa (Spain); Duro, L. [ENVIROS-SPAIN S.L. Passeig de Rubi 29-31, 08197 Valldoreix (Spain)

    2006-03-15

    In this work, we have studied the sorption of selenium ({sup 79}Se is one of the main radionuclides in a spent nuclear fuel repository) on magnetite (Fe{sub 3}O{sub 4}), a mineral present in the near-field of a nuclear waste repository that might represent an important retardation factor for the mobility of many radionuclides. The sorption of both Se(IV) and Se(VI) onto magnetite has been fitted by a non-competitive Langmuir isotherm with {gamma} {sub max} = (3.13 {+-} 0.07) x 10{sup -6} mol m{sup -2} and K {sub L} = (1.19 {+-} 0.07) x 10{sup 6} dm{sup 3} mol{sup -1} for Se(IV) and {gamma} {sub max} = (3.5 {+-} 0.2) x 10{sup -6} mol m{sup -2} and K {sub L} = (3.0 {+-} 0.1) x 10{sup 5} dm{sup 3} mol{sup -1} for Se(VI). The variation of the sorption of selenium with pH has been modeled using the Triple Layer Surface Complexation Model and the equilibrium constants between selenium and magnetite have been obtained using the FITEQL program. For the case of Se(IV), the best fitting has been obtained using two inner-sphere complexes, FeOHSeO{sub 3} {sup 2-} and FeHSeO{sub 3}, while for Se(VI), the best fitting has been obtained considering only an outer-sphere complex, FeOH{sub 2} {sup +} -SeO{sub 4} {sup 2-}. The surface complexation reactions derived in this work are in agreement with those stated by other authors for sorption of Se(IV) and Se(VI) on hydrous iron oxides.

  14. Construction of Chaihu Selenium Industrial Demonstration Area in Zhongxiang City of Hubei Province

    Institute of Scientific and Technical Information of China (English)

    Guangzhong; DAI

    2014-01-01

    In order to develop selenium industry in Jianghan Basin,Hubei Provincial Party Committee decided to build Chaihu selenium industrial demonstration area in Zhongxiang City.This paper introduced general situation of Chaihu Town,analyzed countermeasures for construction of selenium industrial demonstration area in depth,and finally came up with 12 constructive and pertinent recommendations.

  15. Bioavailibility of selenium from fish, yeast and selenate: a comparative study in humans using stable isotopes

    NARCIS (Netherlands)

    Fox, T.E.; Heuvel, van den E.G.H.M.; Atherton, C.A.; Luten, J.B.; Hoek-van Nieuwenhuizen, van M.; Kotterman, M.J.J.

    2004-01-01

    Objective: To measure the bioavailability of selenium from cooked and raw fish in humans by estimating and comparing apparent absorption and retention of selenium in biosynthetically labelled fish with labelled selenate and biosynthetically labelled selenium in brewers yeast. Design: The interventio

  16. Selenium status, thyroid volume, and multiple nodule formation in an area with mild iodine deficiency

    DEFF Research Database (Denmark)

    Rasmussen, Lone Banke; Schomburg, Lutz; Köhrle, Josef;

    2011-01-01

    The objective was to study the associations between serum selenium concentration and thyroid volume, as well as the association between serum selenium concentration and risk for an enlarged thyroid gland in an area with mild iodine deficiency before and after iodine fortification was introduced....... Another objective was to examine the association between serum selenium concentration and prevalence of thyroid nodules....

  17. Speciation of Selenium in Stream Insects Using X-Ray Absorption Spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Andrahennadi, R.; Wayland, M.; Pickering, I.J.

    2009-05-28

    Selenium contamination in the environment is a widespread problem affecting insects and other wildlife. Insects occupy a critical middle link and aid in trophic transfer of selenium in many terrestrial and freshwater food chains, but the mechanisms of selenium uptake through the food chain are poorly understood. In particular, biotransformation of selenium by insects into different chemical forms will greatly influence how toxic or benign the selenium is to that organism or to its predators. We have used X-ray absorption spectroscopy (XAS) to identify the chemical form of selenium in insects inhabiting selenium contaminated streams near Hinton, Alberta (Canada). Selenium K near-edge spectra indicate a variability of selenium speciation among the insects that included mayflies (Ephemeroptera), stoneflies (Plecoptera), caddisflies (Trichoptera), and craneflies (Diptera). Higher percentages of inorganic selenium were observed in primary consumers, detritivores, and filter feeders than in predatory insects. Among the organic forms of selenium, organic selenides constituted a major fraction in most organisms. A species modeled as trimethylselenonium was observed during the pupal stage of caddisflies. These results provide insights into how the insects cope with their toxic cargo, including how the selenium is biotransformed into less toxic forms and how it can be eliminated from the insects. More broadly, this study demonstrates the strengths of XAS to probe the effects of heavy elements at trace levels in insects from the field.

  18. Speciation of selenium in stream insects using X-ray absorption spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Ruwandi Andrahennadi; Mark Wayland; Ingrid J. Pickering [University of Saskatchewan, Saskatoon, SK (Canada). Department of Geological Sciences

    2007-11-15

    Selenium contamination in the environment is a widespread problem affecting insects and other wildlife. Insects occupy a critical middle link and aid in trophic transfer of selenium in many terrestrial and freshwater food chains, but the mechanisms of selenium uptake through the food chain are poorly understood. In particular, biotransformation of selenium by insects into different chemical forms will greatly influence how toxic or benign the selenium is to that organism or to its predators. We have used X-ray absorption spectroscopy (XAS) to identify the chemical form of selenium in insects inhabiting selenium contaminated streams near Hinton, Alberta (Canada). Selenium K near-edge spectra indicate a variability of selenium speciation among the insects that included mayflies (Ephemeroptera), stoneflies (Plecoptera), caddisflies (Trichoptera), and craneflies (Diptera). Higher percentages of inorganic selenium were observed in primary consumers, detritivores, and filter feeders than in predatory insects. Among the organic forms of selenium, organic selenides constituted a major fraction in most organisms. A species modeled as trimethylselenonium was observed during the pupal stage of caddisflies. These results provide insights into how the insects cope with their toxic cargo, including how the selenium is biotransformed into less toxic forms and how it can be eliminated from the insects. More broadly, this study demonstrates the strengths of XAS to probe the effects of heavy elements at trace levels in insects from the field.

  19. Bioavailability of selenium from fish, yeast and selenate: A comparative study in humans using stable isotopes

    NARCIS (Netherlands)

    Fox, T.E.; Heuvel, E.G.H.M. van den; Atherton, C.A.; Dainty, J.R.; Lewis, D.J.; Langford, N.J.; Crews, H.M.; Luten, J.B.; Lorentzen, M.; Sieling, F.W.; Aken-Schneyder, P. van; Hoek, M.; Kotterman, M.J.J.; Dael, P. van; Firweather-Tail, S.J.