WorldWideScience

Sample records for ambient vibration measurements

  1. NIF Ambient Vibration Measurements

    International Nuclear Information System (INIS)

    LLNL has an ongoing research and development project that includes developing data acquisition systems with remote wireless communication for monitoring the vibrations of large civil engineering structures. In order to establish the capability of performing remote sensing over an extended period of time, the researchers needed to apply this technology to a real structure. The construction of the National Ignition Facility provided an opportunity to test the data acquisition system on a large structure to monitor whether the facility is remaining within the strict ambient vibration guidelines. This document will briefly discuss the NIF ambient vibration requirements and summarize the vibration measurements performed during the Spring and Summer of 1999. In addition, a brief description of the sensors and the data acquisition systems will be provided in Appendix B

  2. Measurement of concrete E-modulus evolution since casting: A novel method based on ambient vibration

    International Nuclear Information System (INIS)

    The use of ambient vibration tests to characterize the evolution of E-modulus of concrete right after casting is investigated in this paper. A new methodology is proposed, which starts by casting a concrete cylindrical beam inside a hollow acrylic formwork. This beam is then placed horizontally, simply supported at both extremities, and vertical accelerations resulting from ambient vibration are measured at mid-span. Processing these mid-span acceleration time series using power spectral density functions allows a continuous identification of the first flexural frequency of vibration of the composite beam, which in turn is correlated with the evolutive E-modulus of concrete since casting. Together with experiments conducted with the proposed methodology, a complementary validation campaign for concrete E-modulus determination was undertaken by static loading tests performed on the composite beam, as well as by standard compressive tests of concrete cylinders of the same batch loaded at different ages.

  3. Underdetermined blind modal identification of structures by earthquake and ambient vibration measurements via sparse component analysis

    Science.gov (United States)

    Amini, Fereidoun; Hedayati, Yousef

    2016-03-01

    Sparse component analysis (SCA) approach was adopted to handle underdetermined blind modal identification of structures, where the number of sensors is less than the number of active modes. To exploit the sparsity of structural responses in time-frequency domain, Short Time Fourier Transform (STFT) was used in this study. The proposed SCA-based approach has two main stages: modal matrix estimation and modal displacement estimation. In the first stage, hierarchical clustering algorithm was used to estimate the modal matrix. The clustering algorithm was preceded by a preprocessing step to select the points in time-frequency domain that only one mode makes contribution in the responses. These points were fed to the clustering algorithm as an input. Performing this analysis enhanced the modal matrix estimation accuracy and reduced the computational cost while conducting clustering analysis. Having estimated mixing matrix, the complex-valued modal responses in the transformed domain were recovered via Smoothed zero-norm (SL-0) algorithm. In a broad sense, using the SL-0 algorithm permits researchers to use any kind of transform in seeking sparsity, regardless of obtaining real-valued or complex-valued signals in transformed domain. Natural frequencies and damping ratios were extracted from the recovered modal responses. Performance of the proposed method was investigated using a synthetic example and a benchmark structure with earthquake and ambient excitation, respectively.

  4. Numerical modeling of the dynamic response of prone-to-fall columns to ambient vibrations: comparison with measurements and potential application

    Science.gov (United States)

    Capron, Alexandre; Valentin, Johann; Jongmans, Denis; Baillet, Laurent; Larose, Eric; Bottelin, Pierre; Donze, Frédéric; Mangeney, Anne

    2015-04-01

    During the last two decades, seismic noise measurements have been increasingly used in gravitational hazard assessment for both investigation and monitoring purposes. The wide frequency range allows ambient vibrations to be applied for investigating geological and civil engineering structures in a great variety of sizes, from the lithospheric or crust scale to a few m-thick landslide and rock column or buildings. On unstable slopes, ambient vibrations have been applied in very different ways for reconnaissance, depending on the investigation purpose and the landslide type. The simplest way to extract information from ambient vibrations on a given site is to perform single-station measurements with a 3-C sensor and to process the records computing Fourier spectra of the three components or the spectral ratio between the horizontal and vertical components (the so-called H/V method). On landslide sites, several studies revealed significant spectral amplification at given frequency and polarization of the wave-field in the direction of maximum slope displacement. They show that different characteristics of the seismic noise (resonant frequencies, polarization, and spectral amplification) could be used from the spectral analysis of the motion or of spectral ratios for characterizing the landslides. For cliff-like sites, this study aims to identify the pertinent and applicable parameters that could be extracted from ambient vibrations and used to gain information on the prone-to-fall column geometry. We first use 2D numerical modeling for better understanding the influence of the rear fracture characteristics (wideness w and depth L) on the horizontal motion H(f), as well as on the spectral ratios H(f)/V(f) and H(f)/Hr(f), where Hr(f) is the horizontal motion measured at a reference site. We then identify the seismic parameters able to characterize the column decoupling and we compare numerical results to data acquired at two rocky sites exhibiting cliff-like geometry

  5. Damage localization under ambient vibration using changes in flexibility

    Science.gov (United States)

    Gao, Yong; Spencer, B. F.

    2002-06-01

    In recent years, Structural Health Monitoring (SHM) has emerged as a new research area in civil engineering. Most existing health monitoring methodologies require direct measurement of input excitation for implementation. However, in many cases, there is no easy way to measure these inputs - or alternatively to externally excite the structure. Therefore, SHM methods based on ambient vibration have become important in civil engineering. In this paper, an approach is proposed based on the Damage Location Vector (DLV) method to handle the ambient vibration case. Here, this flexibility-matrix-based damage localization method is combined with a modal expansion technique to eliminate the need to measure the input excitation. As a by-product of this approach, in addition to determining the location of the damage, an estimate of the damage extent also can be determined. Finally, a numerical example analyzing a truss structure with limited sensors and noisy measurement is provided to verify the efficacy of the proposed approach.

  6. Ambient Vibration Test for a Multi-story Residential Building and the Vibration Mitigation Measures%多层住宅环境振动影响测试与减振措施分析

    Institute of Scientific and Technical Information of China (English)

    朱斌; 陈龙珠; 丁力

    2014-01-01

    Brick-concrete buildings have been extensively used in urban and rural areas.However,this type of building,which frequently contains a shallow foundation,demonstrates poor struc-tural integrity and is susceptible to influence from ambient vibrations.This case is especially validfor buildings that were constructed in previous eras.With the development of modern cities andthe increasing demand for an enhanced quality of life,environmental interference caused by ambi-ent vibrations has become a critical issue.In areas with soft soil,traffic is a primary source ofambient vibrations.Vehicle vibrations caused by road surface roughness or speed changes cancause vibrations throughout the foundation of a building.Therefore,the vibration of brick-con-crete buildings is related not only to the excitation source of the vibration but also the soil charac-teristics,the foundation conditions,and the structural style.The human response to the vibra-tions of housing structures is closely correlated with a person's cognitive level and their currentphysical and psychological conditions.Thus,the potential difference in the reactions amongbuilding occupants is significant.Residents in a six-story brick-concrete building,which is located in an area of Shanghai withsoft ground,frequently complained about the intermittent interference from vibrations,particularly residents on the upper two stories.The measures confirmed that the environmental vibra-tions were generated by heavy vehicles traveling on a road that was located approximately 80 mnorth of the building.The frequency and amplitude characteristics of the ambient vibrations andthe human comfort levels for the different stories of the building were analyzed according to the"standard for allowable vibration of building engineering"(GB50868-2013).To comprehensivelyevaluate the impact induced by the transversely horizontal vibrations,which influences humancomfort levels for the three components of building vibration,a numerical finite

  7. Blade Vibration Measurement System

    Science.gov (United States)

    Platt, Michael J.

    2014-01-01

    The Phase I project successfully demonstrated that an advanced noncontacting stress measurement system (NSMS) could improve classification of blade vibration response in terms of mistuning and closely spaced modes. The Phase II work confirmed the microwave sensor design process, modified the sensor so it is compatible as an upgrade to existing NSMS, and improved and finalized the NSMS software. The result will be stand-alone radar/tip timing radar signal conditioning for current conventional NSMS users (as an upgrade) and new users. The hybrid system will use frequency data and relative mode vibration levels from the radar sensor to provide substantially superior capabilities over current blade-vibration measurement technology. This frequency data, coupled with a reduced number of tip timing probes, will result in a system capable of detecting complex blade vibrations that would confound traditional NSMS systems. The hardware and software package was validated on a compressor rig at Mechanical Solutions, Inc. (MSI). Finally, the hybrid radar/tip timing NSMS software package and associated sensor hardware will be installed for use in the NASA Glenn spin pit test facility.

  8. Analysis of soil-structure interaction due to ambient vibration

    Energy Technology Data Exchange (ETDEWEB)

    Tabatabaie, M., Sommer, S.C.

    1998-03-27

    This paper presents the results of a study to evaluate the effects of soil-structure interaction (SSI) on the ambient vibration response of the switchyard/target area (S/TA) buildings at the National Ignition Facility (NIF) presently under construction at the Lawrence Livermore National Laboratory (LLNL) in Livermore, California. This laser facility houses optical and other special equipment whose alignment stability is sensitive to vibrations caused by ambient vibrations or other vibrating sources. In evaluating the deformations and displacements of the S/TA structures, the contribution of the SSI to the overall system flexibility can be very significant. The present study examines the results of fixed-base and SSI analyses of these massive stiff structures to develop an understanding of the potential contribution of SSI to the overall system displacements and deformations. A simple procedure using a set of factors is recommended for scaling the results of fixed-base analyses to approximately account for SSI effects.

  9. Identification of aeroelastic forces and static drag coefficients of a twin cable bridge stay from full-scale ambient vibration measurements

    DEFF Research Database (Denmark)

    Acampora, Antonio; Georgakis, Christos T.; Macdonald, J.H.G.;

    2014-01-01

    excitation from the deck and/or towers. Although there have been many observations of large cable vibrations on bridges, there are relatively few cases of direct full-scale cable vibration and wind measurements, and most research has been based on wind tunnel tests and theoretical modelling.This paper...... presents results from full-scale measurements on the special arrangement of twin cables adopted for the Øresund Bridge. The monitoring system records wind and weather conditions, as well as accelerations of certain cables and a few locations on the deck and tower. Using the Eigenvalue Realization Algorithm......-scale measurements are compared with the theoretical damping matrices based on the quasi-steady theory, using three different sets of wind tunnel measurements of static force coefficients on similar shaped twin or single cables, with good agreement. The damping terms are found to be dependent on Reynolds number...

  10. Ambient vibrations efficiency for building dynamic characteristics estimate and seismic evaluation.

    OpenAIRE

    Dunand, François

    2005-01-01

    Ambient vibrations are mechanical low amplitude vibrations generated by human and natural activities. By forcing into vibration engineering structures, these vibrations can be used to estimate the structural dynamic characteristics.The goal of this study is to compare building dynamic characteristics derived from ambient vibrations to those derived from more energetic solicitations (e.g. earthquake). This study validates the efficiency of this method and shows that ambient vibrations results ...

  11. Damping Estimation Using Free Decays and Ambient Vibration Tests

    DEFF Research Database (Denmark)

    Magalhães, Filipe; Brincker, Rune; Cunha, Álvaro

    The accurate identification of modal damping ratios of Civil Engineering structures is a subject of major importance, as the amplitude of structural vibrations in resonance is inversely proportional to these coefficients. Their experimental identification can be performed either from ambient...... in Civil Engineering structures have shown some discrepancies [1, 2]. Thus, it is important to evaluate the accuracy of the available testing alternatives....

  12. FEM Updating of Tall Buildings using Ambient Vibration Data

    DEFF Research Database (Denmark)

    Ventura, C. E.; Lord, J. F.; Turek, M.;

    2005-01-01

    Ambient vibration testing is the most economical non-destructive testing method to acquire vibration data from large civil engineering structures. The purpose of this paper is to demonstrate how ambient vibration Modal Identification techniques can be effectively used with Model Updating tools to...... develop reliable finite element models of large civil engineering structures. A fifteen story and a forty-eight story reinforced concrete buildings are used as case studies for this purpose. The dynamic characteristics of interest for this study were the first few lateral and torsional natural frequencies...... parameters to be modified by the updating software in order to ensure that the necessary changes to the model were realistic and physically realisable and meaningful. The paper highlights the model updating process and provides an assessment of the usefulness of using an automatic model updating procedure...

  13. Response of APS storage ring basemat to ambient vibration

    International Nuclear Information System (INIS)

    The storage ring of the Advanced Photon Source (APS) facility at Argonne is very sensitive to vibration. Large vibration amplitudes would result in degraded machine performance. Because the storage ring assembly is supported on the storage ring basemat, the dynamics of the basemat are critical to successful operation. Before construction began, a survey of site ground vibration indicated that the site was acceptable from a vibration standpoint. When construction of the linear accelerator (Linac) floor slab and shielding walls was completed, dynamic-response measurements were conducted. The slab/wall system showed attenuation of soilborne vibrations in the horizontal directions, but an amplification (approximately a factor of 1.5) of vertical vibration at a frequency of 7.7 Hz. Vibration response of the slab/wall system at all other frequencies showed attenuation of soilborne vibrations. Dynamic-response measurements were also conducted on an incomplete section of the storage ring basemat. Although this section was not prototypical, results were similar to those of the Linac floor in the horizontal direction, showing large damping and attenuation of horizontal soilborne vibrations. While the basemat followed the soil vibration in the vertical direction, no large amplification was observed. However, measured vertical amplitudes on the basemat were a function of location, indicating a modal response. A series of vibration response measurements was conducted on a completed section of the storage ring basemat/tunnel adjacent and to the west of the Early Assembly Area (EAA) on May 21, 1992, and is the subject of this report

  14. The Health Monitoring Method of Concrete Dams Based on Ambient Vibration Testing and Kernel Principle Analysis

    OpenAIRE

    Lin Cheng; Jie Yang; Dongjian Zheng; Bo Li; Jie Ren

    2015-01-01

    The ambient vibration testing (AVT) measurement of concrete dams on full-scale can show the practical dynamic properties of structure in the operation state. For most current researches, the AVT data is generally analyzed to identify the structural vibration characteristics, that is, modal parameters. The identified modal parameters, which can provide the global damage information or the damage location information of structure, can be used as the basis of structure health monitoring. Therefo...

  15. On Modal Parameter Estimates from Ambient Vibration Tests

    DEFF Research Database (Denmark)

    Agneni, A.; Brincker, Rune; Coppotelli, B.

    2004-01-01

    Modal parameter estimates from ambient vibration testing are turning into the preferred technique when one is interested in systems under actual loadings and operational conditions. Moreover, with this approach, expensive devices to excite the structure are not needed, since it can be adequately...... excited by human activities, wind, gust, etc. In this paper, the comparison between two differeiit vibration testing techniques is presented. The first approach takes advantage of the Frequency Domain Decomposition, FDD, of the response cross power spectral densities to estimate both the natural...... parameters of two simple structures (a beam and a plate), excited by an acoustical random signal....

  16. Vibration of a Cantilever Beam in Ambient Fluid

    CERN Document Server

    Metzger, C; Zypman, F

    2016-01-01

    Here we obtain analytical expressions for the frequency response of a cantilever beam in the presence of ambient fluid. The advantage of our approach, besides its simplicity of use, is that it explicitly contains the viscosity and the density of the ambient fluid. Thus, if measuring the frequency spectrum, the expression can be used in the design of viscometers. Conversely, if the ambient fluid is known, the expression can be used in the design of force gauges such as in Atomic Force Microscopy.

  17. Effects of ambient vibrations on heritage buildings: overview and wireless dynamic monitoring application

    International Nuclear Information System (INIS)

    Growing awareness of the negative effects due to ambient vibrations caused by transportations infrastructures in Historical centres is attributable to the high vulnerability of heritage buildings as a consequence of deterioration phenomena and damages that reduced the structural capacity of such valuable constructions over the past centuries. As the mobility demand increases, several cities hosting heritage buildings are subjected to raising traffic loadings, so that constructions of new infrastructures is often required. Hence, assessing the effects of short-term vibrations due to construction activities or the consequences of the long-term vibrations caused by traffic is very important for the preservation of cultural heritage. An operative approach for evaluating the effects of ambient vibrations based on experimental measurements is a useful tool when a new infrastructure is being built, and can support strategic decisions for the elaboration of transportation plans at the urban level. Therefore, an overview is here presented of existing studies, guidelines and codes that provide pertinent information on this topic. Of special importance is the analysis of existing proposed thresholds, i.e. limit values that, if compiled with, damage due to ambient vibrations is not likely to occur. On the basis of such overview, the selection of threshold values for the Flavian Amphitheater is discussed, along with current efforts towards a wireless dynamic monitoring of its dynamic response.

  18. Underground measurements of seismic vibrations at the SSC site

    International Nuclear Information System (INIS)

    The results of underground measurements of seismic vibrations at the tunnel depth of the Superconducting Super Collider (SSC) site are presented. Spectral analysis of the data obtained in the frequency band from 0.05 Hz to 1500 Hz is performed. It is found that amplitudes of ambient ground motion are less than requirements for the Collider, but cultural vibrations are unacceptably large and will cause fast growth of transverse emittance of the SSC beams

  19. Surveying techniques in vibration measurement

    OpenAIRE

    Kuras Przemyslaw

    2015-01-01

    In order to determine the actual dynamic characteristics of engineering structures, it is necessary to perform direct measurements. The paper focuses on the problem of using various devices to measure vibration, with particular emphasis on surveying instruments. The main tool used in this study is the radar interferometer, which has been compared to: robotic total station, GNSS receivers and sensors (accelerometer and encoder). The results of four dynamic experiments are presented. They were ...

  20. Ambient Vibration Based Damage Diagnosis Using Statistical Modal Filtering and Genetic Algorithm: A Bridge Case Study

    Directory of Open Access Journals (Sweden)

    S. El-Ouafi Bahlous

    2013-01-01

    Full Text Available The authors recently developed a damage identification method which combines ambient vibration measurements and a Statistical Modal Filtering approach to predict the location and degree of damage. The method was then validated experimentally via ambient vibration tests conducted on full-scale reinforced concrete laboratory specimens. The main purpose of this paper is to demonstrate the feasibility of the identification method for a real bridge. An important challenge in this case is to overcome the absence of vibration measurements for the structure in its undamaged state which corresponds ideally to the reference state of the structure. The damage identification method is, therefore, modified to adapt it to the present situation where the intact state was not subjected to measurements. An additional refinement of the method consists of using a genetic algorithm to improve the computational efficiency of the damage localization method. This is particularly suited for a real case study where the number of damage parameters becomes significant. The damage diagnosis predictions suggest that the diagnosed bridge is damaged in four elements among a total of 168 elements with degrees of damage varying from 6% to 18%.

  1. Surveying techniques in vibration measurement

    Directory of Open Access Journals (Sweden)

    Kuras Przemyslaw

    2015-01-01

    Full Text Available In order to determine the actual dynamic characteristics of engineering structures, it is necessary to perform direct measurements. The paper focuses on the problem of using various devices to measure vibration, with particular emphasis on surveying instruments. The main tool used in this study is the radar interferometer, which has been compared to: robotic total station, GNSS receivers and sensors (accelerometer and encoder. The results of four dynamic experiments are presented. They were performed on: industrial chimney, drilling tower, railway bridge and pedestrian footbridge. The obtained results have been discussed in terms of the requirements imposed by the standard ISO 4866:2010.

  2. Measurement of vibration in machine tools

    OpenAIRE

    Helienek, Matúš

    2014-01-01

    This thesis contains general introduction to vibrodiagnostics starting with definition and classification of vibrations. Furthermore the thesis describes the theory of data acquisition of vibration intensity. This section includes also types of sensors, which are used for vibration measuring. Practical part deals with measurement as well as evaluation of cutting process.

  3. Vibration measurement and modal analysis for tunneller

    Institute of Scientific and Technical Information of China (English)

    HUANG Min; WU Miao; WEI Ren-zhi

    2001-01-01

    In this paper, the method of vibration measurement and modal analysis for AM~50 Tunneller machine is presented. When the machine was used for cutting man-made coal bed and real coal bed, the vibration of the machine was measured and the results of signal analysis show that the vibration characteristics under the two kinds of working situations are similar. The modal model of the machine is established, and then, the intrinsic vibration characteristics of AM50 tunneller are investigated by means of the method of experimental modal analysis. The vibration response simulation under a set of loading spectra measured is carried out by force response simulation software.

  4. Estimation of Subjective Difficulty and Psychological Stress by Ambient Sensing of Desk Panel Vibrations

    Science.gov (United States)

    Hamaguchi, Nana; Yamamoto, Keiko; Iwai, Daisuke; Sato, Kosuke

    We investigate ambient sensing techniques that recognize writer's psychological states by measuring vibrations of handwriting on a desk panel using a piezoelectric contact sensor attached to its underside. In particular, we describe a technique for estimating the subjective difficulty of a question for a student as the ratio of the time duration of thinking to the total amount of time spent on the question. Through experiments, we confirm that our technique correctly recognizes whether or not a person writes something down on paper by measured vibration data at the accuracy of over 80 %, and that the order of computed subjective difficulties of three questions is coincident with that reported by the subject in 60 % of experiments. We also propose a technique to estimate a writer's psychological stress by using the standard deviation of the spectrum of the measured vibration. Results of a proof-of-concept experiment show that the proposed technique correctly estimates whether or not the subject feels stress at least 90 % of the time.

  5. The Health Monitoring Method of Concrete Dams Based on Ambient Vibration Testing and Kernel Principle Analysis

    Directory of Open Access Journals (Sweden)

    Lin Cheng

    2015-01-01

    Full Text Available The ambient vibration testing (AVT measurement of concrete dams on full-scale can show the practical dynamic properties of structure in the operation state. For most current researches, the AVT data is generally analyzed to identify the structural vibration characteristics, that is, modal parameters. The identified modal parameters, which can provide the global damage information or the damage location information of structure, can be used as the basis of structure health monitoring. Therefore, in this paper, the health monitoring method of concrete dams based on the AVT is studied. The kernel principle analysis (KPCA based method is adopted to eliminate the effect of environmental variables and monitor the health of dam under varying environments. By taking full advantage of the AVT data obtained from vibration observation system of dam, the identification capabilities and the warning capabilities of structural damage can be improved. With the simulated AVT data of the numerical model of a concrete gravity dam and the measured AVT data of a practical engineering, the performance of the dam health monitoring method proposed in this paper is verified.

  6. Materials for Damping Ambient Acoustic and Vibration Signals Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Long-term exposure to even relatively low levels of acoustic and vibration signals has been shown to be potentially harmful to humans. A new class of piezoelectric...

  7. Ocean Ambient Noise Measurement and Theory

    CERN Document Server

    Carey, William M

    2011-01-01

    This book develops the theory of ocean ambient noise mechanisms and measurements, and also describes general noise characteristics and computational methods.  It concisely summarizes the vast ambient noise literature using theory combined with key representative results.  The air-sea boundary interaction zone is described in terms of non-dimensional variables requisite for future experiments.  Noise field coherency, rare directional measurements, and unique basin scale computations and methods are presented.  The use of satellite measurements in these basin scale models is demonstrated.  Finally, this book provides a series of appendices giving in-depth mathematical treatments.  With its complete and careful discussions of both theory and experimental results, this book will be of the greatest interest to graduate students and active researchers working in fields related to ambient noise in the ocean.

  8. A Hybrid Indoor Ambient Light and Vibration Energy Harvester for Wireless Sensor Nodes

    OpenAIRE

    Hua Yu; Qiuqin Yue; Jielin Zhou; Wei Wang

    2014-01-01

    To take advantage of applications where both light and vibration energy are available, a hybrid indoor ambient light and vibration energy harvesting scheme is proposed in this paper. This scheme uses only one power conditioning circuit to condition the combined output power harvested from both energy sources so as to reduce the power dissipation. In order to more accurately predict the instantaneous power harvested from the solar panel, an improved five-parameter model for small-scale solar p...

  9. Dynamic test and finite element model updating of bridge structures based on ambient vibration

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    The dynamic characteristics of bridge structures are the basis of structural dynamic response and seismic analysis,and are also an important target of health condition monitoring.In this paper,a three-dimensional finite-element model is first established for a highway bridge over a railroad on No.312 National Highway.Based on design drawings,the dynamic characteristics of the bridge are studied using finite element analysis and ambient vibration measurements.Thus,a set of data is selected based on sensitivity analysis and optimization theory;the finite element model of the bridge is updated.The numerical and experimental results show that the updated method is more simple and effective,the updated finite element model can reflect the dynamic characteristics of the bridge better,and it can be used to predict the dynamic response under complex external forces.It is also helpful for further damage identification and health condition monitoring.

  10. Some measurements of ambient air pollution

    International Nuclear Information System (INIS)

    Ambient air pollution arising from different sources in Karachi and its surroundings has been studied. The urban centres like Karachi are mostly confronted with eye-irritation, reduce visibility, heart-diseases, nervous disorder, smog and other unpleasant experiences. In this paper quantitative estimations of some air-pollutants such as sulphur dioxide, carbon monoxide, oxides of nitrogen, chlorine and particular matters are presented with their hazardous effects. The remedial measures for the control of major air emissions are also discussed. (author)

  11. A METHOD OF ONLINE DAMAGE IDENTIFICATION FOR STRUCTURES BASED ON AMBIENT VIBRATION

    Institute of Scientific and Technical Information of China (English)

    YAO Zhi-yuan; WANG Feng-quan; ZHAO Chun-sheng

    2005-01-01

    A method of damage identification for engineering structures based on ambient vibration is put forward, in which output data are used only. Firstly, it was identification of the statistic parameters to associate with the exterior excitation for undamaged structures.Then it was detection and location of the structural damages for damaged structures. The ambient identification method includes a theoretical model and numerical method. The numerical experiment results show the method is precise and effective. This method may be used in health monitoring for bridges and architectures.

  12. SMA actuators for vibration control and experimental determination of model parameters dependent on ambient airflow velocity

    Science.gov (United States)

    Suzuki, Y.

    2016-05-01

    This article demonstrates the practical applicability of a method of modelling shape memory alloys (SMAs) as actuators. For this study, a pair of SMA wires was installed in an antagonistic manner to form an actuator, and a linear differential equation that describes the behaviour of the actuator’s generated force relative to its input voltage was derived for the limited range below the austenite onset temperature. In this range, hysteresis need not be considered, and the proposed SMA actuator can therefore be practically applied in linear control systems, which is significant because large deformations accompanied by hysteresis do not necessarily occur in most vibration control cases. When specific values of the parameters used in the differential equation were identified experimentally, it became clear that one of the parameters was dependent on ambient airflow velocity. The values of this dependent parameter were obtained using an additional SMA wire as a sensor. In these experiments, while the airflow distribution around the SMA wires was varied by changing the rotational speed of the fans in the wind tunnels, an input voltage was conveyed to the SMA actuator circuit, and the generated force was measured. In this way, the parameter dependent on airflow velocity was estimated in real time, and it was validated that the calculated force was consistent with the measured one.

  13. Study of the Ambient Vibration Energy Harvesting Based on Piezoelectric Effect

    Science.gov (United States)

    Si, Hongyu; Dong, Jinlu; Chen, Lei; Sun, Laizhi; Zhang, Xiaodong; Gao, Mintian

    2014-01-01

    The resonance between piezoelectric vibrator and the vibration source is the key to maximize the ambient vibration energy harvesting by using piezoelectric generator. In this paper, the factors that influence the output power of a single piezoelectric vibrator are analyzed. The effect of geometry size (length, thickness, width of piezoelectric chip and thickness of metal shim) of a single cantilever piezoelectric vibrator to the output power is analyzed and simulated with the help of MATLAB (matrix laboratory). The curves that output power varies with geometry size are obtained when the displacement and load at the free end are constant. Then the paper points out multi-resonant frequency piezoelectric power generation, including cantilever multi-resonant frequency piezoelectric power generation and disc type multi-resonant frequency piezoelectric generation. Multi-resonant frequency of cantilever piezoelectric power generation can be realized by placing different quality mass at the free end, while disc type multi-resonant frequency piezoelectric generation can be realized through series and parallel connection of piezoelectric vibrator.

  14. Ambient Vibration Tests of an Arch Dam with Different Reservoir Water Levels: Experimental Results and Comparison with Finite Element Modelling

    Directory of Open Access Journals (Sweden)

    Sergio Vincenzo Calcina

    2014-01-01

    Full Text Available This paper deals with the ambient vibration tests performed in an arch dam in two different working conditions in order to assess the effect produced by two different reservoir water levels on the structural vibration properties. The study consists of an experimental part and a numerical part. The experimental tests were carried out in two different periods of the year, at the beginning of autumn (October 2012 and at the end of winter (March 2013, respectively. The measurements were performed using a fast technique based on asynchronous records of microtremor time-series. In-contact single-station measurements were done by means of one single high resolution triaxial tromometer and two low-frequency seismometers, placed in different points of the structure. The Standard Spectral Ratio method has been used to evaluate the natural frequencies of vibration of the structure. A 3D finite element model of the arch dam-reservoir-foundation system has been developed to verify analytically determined vibration properties, such as natural frequencies and mode shapes, and their changes linked to water level with the experimental results.

  15. Optical Measurement of Cable and String Vibration

    Directory of Open Access Journals (Sweden)

    Y. Achkire

    1998-01-01

    Full Text Available This paper describes a non contacting measurement technique for the transverse vibration of small cables and strings using an analog position sensing detector. On the one hand, the sensor is used to monitor the cable vibrations of a small scale mock-up of a cable structure in order to validate the nonlinear cable dynamics model. On the other hand, the optical sensor is used to evaluate the performance of an active tendon control algorithm with guaranteed stability properties. It is demonstrated experimentally, that a force feedback control law based on a collocated force sensor measuring the tension in the cable is feasible and provides active damping in the cable.

  16. A hybrid indoor ambient light and vibration energy harvester for wireless sensor nodes.

    Science.gov (United States)

    Yu, Hua; Yue, Qiuqin; Zhou, Jielin; Wang, Wei

    2014-01-01

    To take advantage of applications where both light and vibration energy are available, a hybrid indoor ambient light and vibration energy harvesting scheme is proposed in this paper. This scheme uses only one power conditioning circuit to condition the combined output power harvested from both energy sources so as to reduce the power dissipation. In order to more accurately predict the instantaneous power harvested from the solar panel, an improved five-parameter model for small-scale solar panel applying in low light illumination is presented. The output voltage is increased by using the MEMS piezoelectric cantilever arrays architecture. It overcomes the disadvantage of traditional MEMS vibration energy harvester with low voltage output. The implementation of the maximum power point tracking (MPPT) for indoor ambient light is implemented using analog discrete components, which improves the whole harvester efficiency significantly compared to the digital signal processor. The output power of the vibration energy harvester is improved by using the impedance matching technique. An efficient mechanism of energy accumulation and bleed-off is also discussed. Experiment results obtained from an amorphous-silicon (a-Si) solar panel of 4.8 × 2.0 cm2 and a fabricated piezoelectric MEMS generator of 11 × 12.4 mm2 show that the hybrid energy harvester achieves a maximum efficiency around 76.7%. PMID:24854054

  17. A Hybrid Indoor Ambient Light and Vibration Energy Harvester for Wireless Sensor Nodes

    Directory of Open Access Journals (Sweden)

    Hua Yu

    2014-05-01

    Full Text Available To take advantage of applications where both light and vibration energy are available, a hybrid indoor ambient light and vibration energy harvesting scheme is proposed in this paper. This scheme uses only one power conditioning circuit to condition the combined output power harvested from both energy sources so as to reduce the power dissipation. In order to more accurately predict the instantaneous power harvested from the solar panel, an improved five-parameter model for small-scale solar panel applying in low light illumination is presented. The output voltage is increased by using the MEMS piezoelectric cantilever arrays architecture. It overcomes the disadvantage of traditional MEMS vibration energy harvester with low voltage output. The implementation of the maximum power point tracking (MPPT for indoor ambient light is implemented using analog discrete components, which improves the whole harvester efficiency significantly compared to the digital signal processor. The output power of the vibration energy harvester is improved by using the impedance matching technique. An efficient mechanism of energy accumulation and bleed-off is also discussed. Experiment results obtained from an amorphous-silicon (a-Si solar panel of 4.8 × 2.0 cm2 and a fabricated piezoelectric MEMS generator of 11 × 12.4 mm2 show that the hybrid energy harvester achieves a maximum efficiency around 76.7%.

  18. Measuring vibrations in fuel channels CNE

    International Nuclear Information System (INIS)

    This paper present a description of implementation and execution of vibration measurements made at the request of NUCLEOELECTRICA ARGENTINA S.A. on the ends of the reactor fuel channels of Embalse Nuclear Power Plant to explore possible differences between the dynamic behavior of empty fuel channel and with full charge of fuel elements inside. (author)

  19. Laser Measurement of Building Vibration and Displacement

    OpenAIRE

    A.J. Bougard; B.R. Ellis

    2000-01-01

    This paper considers four laser systems used by the Building Research Establishment (BRE) to investigate the behaviour of structures. Lasers enable remote measurements of vibration and displacement to be taken where access to a structure is difficult or where fire, explosion or structural collapse creates a hazardous environment. Each system will be described, and its use illustrated using measurements taken on real structures.The four systems are:1. Laser Interferometer: This is used to meas...

  20. Measurements of vibrational parameters for pump testing

    International Nuclear Information System (INIS)

    Determining a pump's condition by vibration measurement requires an understanding of the generated forces, the equations of motion of the machine's structure, and the effect that instrumentation has on the measurements. Unbalance, misalignment, bearing damage, off design operation (miniflow, cavitation), and other machinery problems generate forces inside the machine which usually can be inferred by the motion of the outside of the machine. These forces are usually generated on the rotor and may cause damage to the rotor or bearings by wear, overload, or fatigue. These forces also cause motion of the structure of the machine which can be measured as displacement, velocity, or acceleration. Within certain limits, this vibration can be used in categorizing the severity of the machine's condition. The measurement system including the transducer, conditioning electronics, calculation choices, and measurement electronics will significantly affect the results. Transducers, with some distortion, transform vibration into electronic signals. Various parameters may be calculated from the resulting wave forms, including four different kinds of amplitude. The waveform can be Fourier transformed, and the resultant spectra analyzed for amplitudes and frequencies

  1. Vibration Measurements on the Frejlev Mast

    DEFF Research Database (Denmark)

    Kirkegaard, Poul Henning; Hansen, Lars Pilegaard

    The present report presents full-scale measurements on the Frejlev-mast which is a 200 meter hight guyed steel mast located 10 km. from Aalborg. The goal of the research was to investigate various techniques which could be used to estimate cable forces from vibration measurements. The cables of the...... Frejlev mast were instrumented in order to measure strains in the cables. However, it was found that the strain signals had a too low signal to noise ratio to be used for further analysis. Since the strain signals could not be used some of the five cables became instrumented with accelerators of cables in...

  2. An Innovative Transponder-Based Interferometric Radar for Vibration Measurements

    International Nuclear Information System (INIS)

    Ground-based radar interferometry has recently emerged as an innovative technology of remote sensing, able to accurately measure the static or dynamic displacement of several points of a structure. This technique in the last couple of years has been applied to different types of structures, such as bridges, towers and chimneys. This paper presents a prototype system developed by IDS, originally aimed at measuring the structural vibrations of helicopter rotor blades, based on an interferometric technique and constituted by combination of a radar sensor and a series of transponders installed on the target structure. The main advantages of this solution with respect to conventional interferometric radars, are related to the increased spatial resolution of the system, provided by the possibility to discriminate different transponders installed within the same resolution cell of the radar sensor, and to the reduction of the ambient noise (e.g. multi-path) on the radar measurement. The first feature allows the use of the microwave technology even on target areas with limited dimensions, such as industrial facilities, while the second aspect may extend the use of radar interferometric systems to complex scenarios, where multi-reflections are expected due to the presence of natural targets with high reflectivity to the radar signal. In the paper, the system and its major characteristics are first described; subsequently, application to the measurement of ambient vibration response of a lab set-up is summarized. Then the data acquired on a rotating mock-up are reported and analyzed to identify natural frequencies and mode shapes of the investigated structure.

  3. An Innovative Transponder-Based Interferometric Radar for Vibration Measurements

    Science.gov (United States)

    Coppi, F.; Cerutti, A.; Farina, P.; De Pasquale, G.; Novembrini, G.

    2010-05-01

    Ground-based radar interferometry has recently emerged as an innovative technology of remote sensing, able to accurately measure the static or dynamic displacement of several points of a structure. This technique in the last couple of years has been applied to different types of structures, such as bridges, towers and chimneys. This paper presents a prototype system developed by IDS, originally aimed at measuring the structural vibrations of helicopter rotor blades, based on an interferometric technique and constituted by combination of a radar sensor and a series of transponders installed on the target structure. The main advantages of this solution with respect to conventional interferometric radars, are related to the increased spatial resolution of the system, provided by the possibility to discriminate different transponders installed within the same resolution cell of the radar sensor, and to the reduction of the ambient noise (e.g. multi-path) on the radar measurement. The first feature allows the use of the microwave technology even on target areas with limited dimensions, such as industrial facilities, while the second aspect may extend the use of radar interferometric systems to complex scenarios, where multi-reflections are expected due to the presence of natural targets with high reflectivity to the radar signal. In the paper, the system and its major characteristics are first described; subsequently, application to the measurement of ambient vibration response of a lab set-up is summarized. Then the data acquired on a rotating mock-up are reported and analyzed to identify natural frequencies and mode shapes of the investigated structure.

  4. Blade Vibration Measurement System for Unducted Fans

    Science.gov (United States)

    Marscher, William

    2014-01-01

    With propulsion research programs focused on new levels of efficiency and noise reduction, two avenues for advanced gas turbine technology are emerging: the geared turbofan and ultrahigh bypass ratio fan engines. Both of these candidates are being pursued as collaborative research projects between NASA and the engine manufacturers. The high bypass concept from GE Aviation is an unducted fan that features a bypass ratio of over 30 along with the accompanying benefits in fuel efficiency. This project improved the test and measurement capabilities of the unducted fan blade dynamic response. In the course of this project, Mechanical Solutions, Inc. (MSI) collaborated with GE Aviation to (1) define the requirements for fan blade measurements; (2) leverage MSI's radar-based system for compressor and turbine blade monitoring; and (3) develop, validate, and deliver a noncontacting blade vibration measurement system for unducted fans.

  5. Laser measurement method of forced vibration in optical systems

    International Nuclear Information System (INIS)

    A forced vibration measurement method by laser combining the laser signal and high frequency CCD in optical systems is introduced. The method solves the conversion problem between the vibration signal and laser signal in optical systems, which can not only measure the impact of vibration on the beam stability, but also acquire the frequency characteristics of vibration signals. Forced vibration in an optical system is measured when the frequencies of vibration signals are 150 Hz and 200 Hz by using the method and the attributes of the vibration signals obtained fits those of the input signals. Test and analysis results demonstrate that the method has a time amplitude uncertainty of 6.25 μm and frequency resolution of 2 Hz. The handy and efficient method, whose measurement is precise, has been applied to the beam pointing stability study of the multiplexing excimer MOPA laser targeting test platform accordingly. (authors)

  6. Noise and Vibrations Measurements. External noise and vibrations measurements for offshore SODAR application

    International Nuclear Information System (INIS)

    The partners in the WISE project investigate whether application of the SODAR (sonic detection and ranging) measurement technique in wind energy experimental work is feasible as a replacement for cup anemometers, wind direction sensors and tall meteorological masts. In Work Package 2 of the WISE project extensive controlled experiments with the SODAR are performed. For example SODAR measurements are compared with measurements from nearby masts and different brands of SODARs are compared. Part of the work package is the measurement of vibration and noise on an offshore SODAR system. The results of these measurements are presented in this report. ECN performed measurements at an offshore location to investigate the influence of noise and vibrations on the performance of a MiniSODAR measurement system. The aim of the measurements is to quantify the effect of these external noise and vibrations disturbances on the MiniSODAR's performance. Measurements on an identical SODAR system onshore are carried out to compare the disturbances of offshore and onshore external conditions. The effect of background noise on SODAR operation has clearly been established in literature. Therefore, measurements have been performed only to establish the absolute sound pressure levels. This is done at the Measuring Platform Noordwijk (MPN) located in the North Sea, nine kilometres out of the coast at Noordwijk, The Netherlands, and at two locations onshore. At the MPN-platform, the SODAR has been moved from the middle deck to the upper deck to diminish the influence of the diesel generator needed for the electric powering of the island. Although the absolute sound pressure level became higher at the new location, this level became lower at the most important frequencies inside the SODAR, due to the use of absorbing foam. With regards to the sound pressure level the move improved the situation. The sound pressure levels measured offshore were 6 to 15 dB higher than for the two locations

  7. A bio-inspired structural health monitoring system based on ambient vibration

    Science.gov (United States)

    Lin, Tzu-Kang; Kiremidjian, Anne; Lei, Chi-Yang

    2010-11-01

    A structural health monitoring (SHM) system based on naïve Bayesian (NB) damage classification and DNA-like expression data was developed in this research. Adapted from the deoxyribonucleic acid (DNA) array concept in molecular biology, the proposed structural health monitoring system is constructed utilizing a double-tier regression process to extract the expression array from the structural time history recorded during external excitations. The extracted array is symbolized as the various genes of the structure from the viewpoint of molecular biology and reflects the possible damage conditions prevalent in the structure. A scaled down, six-story steel building mounted on the shaking table of the National Center for Research on Earthquake Engineering (NCREE) was used as the benchmark. The structural response at different damage levels and locations under ambient vibration was collected to support the database for the proposed SHM system. To improve the precision of detection in practical applications, the system was enhanced by an optimization process using the likelihood selection method. The obtained array representing the DNA array of the health condition of the structure was first evaluated and ranked. A total of 12 groups of expression arrays were regenerated from a combination of four damage conditions. To keep the length of the array unchanged, the best 16 coefficients from every expression array were selected to form the optimized SHM system. Test results from the ambient vibrations showed that the detection accuracy of the structural damage could be greatly enhanced by the optimized expression array, when compared to the original system. Practical verification also demonstrated that a rapid and reliable result could be given by the final system within 1 min. The proposed system implements the idea of transplanting the DNA array concept from molecular biology into the field of SHM.

  8. A bio-inspired structural health monitoring system based on ambient vibration

    International Nuclear Information System (INIS)

    A structural health monitoring (SHM) system based on naïve Bayesian (NB) damage classification and DNA-like expression data was developed in this research. Adapted from the deoxyribonucleic acid (DNA) array concept in molecular biology, the proposed structural health monitoring system is constructed utilizing a double-tier regression process to extract the expression array from the structural time history recorded during external excitations. The extracted array is symbolized as the various genes of the structure from the viewpoint of molecular biology and reflects the possible damage conditions prevalent in the structure. A scaled down, six-story steel building mounted on the shaking table of the National Center for Research on Earthquake Engineering (NCREE) was used as the benchmark. The structural response at different damage levels and locations under ambient vibration was collected to support the database for the proposed SHM system. To improve the precision of detection in practical applications, the system was enhanced by an optimization process using the likelihood selection method. The obtained array representing the DNA array of the health condition of the structure was first evaluated and ranked. A total of 12 groups of expression arrays were regenerated from a combination of four damage conditions. To keep the length of the array unchanged, the best 16 coefficients from every expression array were selected to form the optimized SHM system. Test results from the ambient vibrations showed that the detection accuracy of the structural damage could be greatly enhanced by the optimized expression array, when compared to the original system. Practical verification also demonstrated that a rapid and reliable result could be given by the final system within 1 min. The proposed system implements the idea of transplanting the DNA array concept from molecular biology into the field of SHM

  9. Vibration Measurement for Rotatory Machines : Importance of maintenance practices

    OpenAIRE

    Tatis, Rolando

    2012-01-01

    This thesis work was done in cooperation with Hi-Tekno Engineering and consulting office. The purpose of this thesis was to demonstrate the importance of vibration measurements in modern day production systems. The aim was to explain how vibration measurements are performed in the field and what kind of machinery diagnosis can be achieved. Effective maintenance services in the production systems of today are vital for any company as to the profitability figures. Vibration measurements giv...

  10. Noncontact vibration measurements using magnetoresistive sensing elements

    Science.gov (United States)

    Tomassini, R.; Rossi, G.

    2016-06-01

    Contactless instrumentations is more and more used in turbomachinery testing thanks to the non-intrusive character and the possibility to monitor all the components of the machine at the same time. Performances of blade tip timing (BTT) measurement systems, used for noncontact turbine blade vibration measurements, in terms of uncertainty and resolution are strongly affected by sensor characteristics and processing methods. The sensors used for BTT generate pulses, used for precise measurements of turbine blades time of arrival. Nowadays proximity sensors used in this application are based on optical, capacitive, eddy current and microwave measuring principle. Pressure sensors has been also tried. This paper summarizes the results achieved using a novel instrumentation based on the magnetoresistive sensing elements. The characterization of the novel probe has been already published. The measurement system was validated in test benches and in a real jet-engine comparing different sensor technologies. The whole instrumentation was improved. The work presented in this paper focuses on the current developments. In particular, attention is given to the data processing software and new sensor configurations.

  11. Analysis of the measurement sensitivity of multidimensional vibrating microprobes

    International Nuclear Information System (INIS)

    A comparison is made between tactile and vibrating microprobes regarding the measurement of typical high aspect ratio microfeatures. It is found that vibrating probes enable the use of styli with higher aspect ratios than tactile probes and are still capable of measuring with high sensitivity. In addition to the one dimensional sensitivity, the directional measurement sensitivity of a vibrating probe is investigated. A vibrating microprobe can perform measurements with high sensitivity in a space spanned by its mode shapes. If the natural frequencies that correspond to these mode shapes are different, the probe shows anisotropic and sub-optimal measurement sensitivity. It is shown that the closer the natural frequencies of the probe are, the better its performance is when regarding optimal and isotropic measurement sensitivity. A novel proof-of-principle setup of a vibrating probe with two nearly equal natural frequencies is realized. This system is able to perform measurements with high and isotropic sensitivity. (paper)

  12. Vibration transfers to measure the performance of vibration isolated platforms on site using background noise excitation

    NARCIS (Netherlands)

    Segerink, F.B.; Korterik, J.P.; Offerhaus, H.L.

    2011-01-01

    This article demonstrates a quick and easy way of quantifying the performance of a vibration-isolated platform. We measure the vibration transfer from floor to table using background noise excitation from the floor. As no excitation device is needed, our setup only requires two identical sensors (in

  13. Vibration monitoring of machines - measurements, diagnosis, status-dependent maintenance

    International Nuclear Information System (INIS)

    In the 'basic' group of subjects, it is explained how measured vibrations on machines can be interpreted by means of vibration technology hypothetical postulates, in order to identify a cracked shaft, increased play in bearings due to wear or a change of out-of-balance, for example. All the examples chosen are practical ones. In the 'operating experience' group of subjects, a survey is given on guidelines in systems of regulations and their application, using concrete examples. Reports on vibration monitoring follow. Modern vibration monitoring systems are introduced, extending from signal detection to information on the operating state of the machine. In the 'monitoring and diagnostic systems' group of subjects, a new solid body noise monitoring system and a modern system of vibration monitoring are introduced by workers from the industry, new ways of processing measured data to improve the information obtained in vibration monitoring are shown and the question of the reliability of monitoring systems is also treated. (orig./GL)

  14. Study of Three-Component FBG Vibration Sensor for Simultaneous Measurement of Vibration, Temperature, and Verticality

    OpenAIRE

    Jiang Shan-chao; Wang Jing; Sui Qing-mei; Ye Qing-lin; Wang Li-jun

    2015-01-01

    To achieve simultaneous measurement of measurand vibration, temperature, and verticality, a three-component fiber Brag grating (TVFBG) vibration sensor is proposed in this paper. Polymer and metal diaphragm sensitization methods are utilized to improve this sensor measurement sensitivity. Project matrix theory is adopted to analyze this sensor. Theoretically, 9×9 nonsingular measuring coefficient matrix of this TVFBG sensor made up by three 3×3 measurand coefficient matrixes is established. ...

  15. Recent Trends of Measurement and Development of VibrationSensors

    OpenAIRE

    Himanshu Chaurasiya

    2012-01-01

    In recent trends, Sensors are devices which monitor a parameter of a system, hopefully without disturbing that parameter. Vibration measurement has become an important method in mechanical structural products research, design, produce, apply and maintenance. Vibration sensor is more and more important as key devices. Nowadays, with the development of computer technology, electronic technology and manufacturing process, a variety of vibration sensors have come forth in succession.

  16. Ambient radiation exposure: measurements and effects

    International Nuclear Information System (INIS)

    A brief review of the available literature, data and reports of various radiation exposure and protection studies and various measurements techniques are presented. A linear quadratic model has been given illustrating the validity of radiation hormesis

  17. Measurement of Vibration Mode Structure for Adaptive Vibration Suppression System by Digital Holography

    Czech Academy of Sciences Publication Activity Database

    Psota, Pavel; Lédl, Vít; Doleček, Roman; Mokrý, P.; Kopecký, V.

    Prague: IEEE-UFFC, 2013 - (Kamba, S.), s. 215-217 ISBN 978-1-4673-5996-2. [2013 Joint UFFC, EFTF and PFM Symposium. Prague (CZ), 21.07.2013-25.07.2013] R&D Projects: GA MŠk(CZ) ED2.1.00/03.0079 Institutional support: RVO:61389021 Keywords : digital holography * vibration measurement * vibration suppression Subject RIV: JB - Sensors, Measurment, Regulation http://ieee2013.fzu.cz/

  18. Energy Harvesting from Ambient Vibrations with Arbitrary In-Plane Motion Directions Using a Magnetostrictive/Piezoelectric Laminate Composite Transducer

    Science.gov (United States)

    Yang, Jin; Wen, Yumei; Li, Ping; Yue, Xihai; Yu, Qiangmo

    2014-07-01

    A magnetoelectric (ME) vibration energy harvester has been designed to scavenge sufficient energy from ambient vibration with arbitrary motion directions in a plane and over a range of frequencies. In the harvester, a circular-cross-section cantilever rod is adopted to extract the vibration energy due to its ability to host accelerations in arbitrary in-plane motion directions. The magnetic coupling between the magnet and the ME transducer results in nonlinear oscillation of the cantilever rod with increased frequency bandwidth. To achieve optimal vibration energy harvesting performance, the effects of the nonlinear vibration and the harvester parameters including the magnetic circuit and the separation distance on the electrical output and the␣working bandwidth are analyzed. The experimental results show that the harvester can scavenge vibration energy in arbitrary in-plane directions, exhibiting a bandwidth of 4.0 Hz and maximum power of 0.22 mW at acceleration of 0.6 g (with g = 9.8 m s-2).

  19. Nondestructive Evaluation of Railway Bridge by System Identification Using Field Vibration Measurement

    International Nuclear Information System (INIS)

    This paper presents a nondestructive evaluation approach for system identification (SID) of real railway bridges using field vibration test results. First, a multi-phase SID scheme designed on the basis of eigenvalue sensitivity concept is presented. Next, the proposed multi-phase approach is evaluated from field vibration tests on a real railway bridge (Wondongcheon bridge) located in Yangsan, Korea. On the steel girder bridge, a few natural frequencies and mode shapes are experimentally measured under the ambient vibration condition. The corresponding modal parameters are numerically calculated from a three-dimensional finite element (FE) model established for the target bridge. Eigenvalue sensitivities are analyzed for potential model-updating parameters of the FE model. Then, structural subsystems are identified phase-by-phase using the proposed model-updating procedure. Based on model-updating results, a baseline model and a nondestructive evaluation of test bridge are identified

  20. Piping vibrations measured during FFTF startup

    International Nuclear Information System (INIS)

    An extensive vibration survey was conducted on the Fast Flux Test Facility piping during the plant acceptance test program. The purpose was to verify that both mechanical and flow induced vibration amplitudes were of sufficiently low level so that pipe and pipe support integrity would not be compromised over the plant design lifetime. Excitation sources included main heat transport sodium pumps, reciprocating auxiliary system pumps, EM pumps, and flow oscillations. Pipe sizes varied from one-inch to twenty-eight-inches in diameter. This paper describes the test plan; the instrumentation and procedures utilized; and the test results

  1. Effect of vehicle weight on natural frequencies of bridges measured from traffic-induced vibration

    Institute of Scientific and Technical Information of China (English)

    2003-01-01

    Recently, ambient vibration test (AVT) is widely used to estimate dynamic characteristics of large civil structures. Dynamic characteristics can be affected by various environmental factors such as humidity, intensity of wind, and temperature. Besides these environmental conditions, the mass of vehicles may change the measured values when traffic-induced vibration is used as a source of AVT for bridges. The effect of vehicle mass on dynamic characteristics is investigated through traffic-induced vibration tests on three bridges; (1) three-span suspension bridge (128m+404m+128m), (2) five-span continuous steel box girder bridge (59m+3@95m+59m), (3) simply supported plate girder bridge (46m). Acceleration histories of each measurement location under normal traffic are recorded for 30 minutes at field. These recorded histories are divided into individual vibrations and are combined into two groups according to the level of vibration; one by heavy vehicles such as trucks and buses and the other by light vehicles such as passenger cars. Separate processing of the two groups of signals shows that, for the middle and long-span bridges, the difference can be hardly detected, but, for the short span bridges whose mass is relatively small, the measured natural frequencies can change up to 5.4%.

  2. Vibration measurements of a wire scanner - Experimental setup and models

    Science.gov (United States)

    Herranz, Juan; Barjau, Ana; Dehning, Bernd

    2016-03-01

    In the next years the luminosity of the LHC will be significantly increased. This will require a much higher accuracy of beam profile measurement than actually achievable by the current wire scanner. The new performance demands a wire travelling speed up to 20 m s-1 and a position measurement accuracy of the order of 1 μm. The vibrations of the mechanical parts of the system and particularly the vibrations of the thin carbon wire have been identified as the major error sources of wire position uncertainty. Therefore the understanding of the wire vibrations has been given high priority for the design and operation of the new device. This article presents a new strategy to measure the wire vibrations based on the piezoresistive effect of the wire itself. An electronic readout system based on a Wheatstone bridge is used to measure the variation of the carbon wire resistance, which is directly proportional to the wire elongation caused by the oscillations.

  3. Investigation of the effect of vibration amplitude on vibration measurements of polarimetric fiber sensors embedded in composite beams

    International Nuclear Information System (INIS)

    Glass fiber reinforced composite material beams embedded with two types of polarimetric sensors are fabricated by the hand layup method and characterized. Two types of polarimetric sensors, a high strain sensitive Panda type fiber and a low strain sensitive polarization maintaining photonic crystal fiber (PM-PCF), are compared for low frequency vibration measurements from 0 to 100 Hz. Different lengths of glass fiber reinforced composite samples with embedded polarimetric sensors are fabricated and compared for different vibration amplitudes and vibration frequencies. The influence of the vibration amplitude of the composite beams on the accuracy of vibration measurements using the two types of polarimetric sensors is investigated. At high amplitude vibrations the low strain sensitive PM-PCF polarimetric sensors offer a wider linear range and thus reproduce the vibration frequency and vibration amplitude accurately. However for high amplitude vibrations the high sensitivity and low dynamic strain range of Panda type fibers result in a multiple-peak intensity pattern within one vibration cycle which leads to inaccurate vibration frequency and vibration amplitude measurements. The experimental results show that the strain sensitivity of polarimetric sensors limits the vibration measurements to a certain range of vibration amplitudes. The vibration amplitude range over which the polarimetric sensors provide accurate information about the vibration frequency is experimentally investigated and the results are presented. Also, for a composite beam undergoing deflections in the ‘simply–simply supported’ configuration, a theoretical method to predict the allowable maximum measurable vibration amplitude for any type of polarimetric sensor, is derived in this paper. It is envisaged that the results from the studies will provide significant information, which can be used in composite material applications such as marine and aerospace for selecting an appropriate type

  4. Dynamic Tire Pressure Sensor for Measuring Ground Vibration

    OpenAIRE

    Wang, Ming L.; James Gregory McDaniel; Qi Wang

    2012-01-01

    This work presents a convenient and non-contact acoustic sensing approach for measuring ground vibration. This approach, which uses an instantaneous dynamic tire pressure sensor (DTPS), possesses the capability to replace the accelerometer or directional microphone currently being used for inspecting pavement conditions. By measuring dynamic pressure changes inside the tire, ground vibration can be amplified and isolated from environmental noise. In this work, verifications of the DTPS concep...

  5. Vibration compensating beam scanning interferometer for surface measurement

    OpenAIRE

    Jiang, Xiang; Martin, Haydn; Wang, Kaiwei

    2007-01-01

    Light beam scanning using a dispersive element and wavelength tuning is coupled with fibre-optic interferometry to realize a new surface measurement instrument. The instrument is capable of measuring nano-scale surface structures and form deviation. It features active vibration compensation and a small optical probe size that may be placed remotely from the main apparatus. Active vibration compensation is provided by the multiplexing of two interferometers with near common paths. Closed loop ...

  6. MEASUREMENT OF ANGULAR VIBRATION AMPLITUDE BY ACTIVELY BLURRED IMAGES

    Institute of Scientific and Technical Information of China (English)

    GUAN Baiqing; WANG Shigang; LIU Chong; LI Qian

    2007-01-01

    A novel motion-blur-based method for measuring the angular amplitude of a high-frequency rotational vibration is schemed. The proposed approach combines the active vision concept and the mechanism of motion-from-blur, generates motion blur on the image plane actively by extending exposure time, and utilizes the motion blur information in polar images to estimate the angular amplitude of a high-frequency rotational vibration. This method obtains the analytical results of the angular vibration amplitude from the geometric moments of a motion blurred polar image and an unblurred image for reference. Experimental results are provided to validate the presented scheme.

  7. ambiental

    Directory of Open Access Journals (Sweden)

    Roque Leal Salcedo

    2008-01-01

    Full Text Available El derecho internacional ambiental es un conocimiento de carácter transversal, que entre otras consideraciones refleja las preocupaciones de la sociedad por la implementación de un modelo de desarrollo sustentable para el respeto a las reglas del medio natural que garantizan la integridad y renovación de los sistemas naturales. El presente artículo enfoca esta visión a través del análisis de material documental revisado, entre ellos tratados internacionales que permiten distinguir el desarrollo del derecho internacional ambiental y el papel de Organización de las Naciones Unidas (ONU, en el propósito común del derecho individual y colectivo de disfrutar de una vida, un ambiente seguro, sano y ecológicamente equilibrado. En función a estas disertaciones las consideraciones finales exponen parte de la visión que ha estructurado la ONU y que representan un aporte considerable en el fomento de la conciencia mundial sobre la necesidad de establecer vínculos entre las naciones para el continuo desarrollo de esta rama del derecho.

  8. Fringe free holographic measurements of large amplitude vibrations

    CERN Document Server

    Joud, Fadwa; Laloë, Franck; Michael, Atlan; Hare, Jean; Gross, Michel

    2010-01-01

    In the measurement of the amplitude of vibration of objects, holographic imaging techniques usually involve fringe counting; due to the limited resolution of images, measurements of large amplitudes are not accessible. We demonstrate a technique that suppresses the necessity of fringe counting: frequency sideband imaging, where the order of the sideband is considered as a marker of the amplitude. The measurement is completely local: no comparison with another reference point on the object is necessary. It involves a sharp variation of a signal, which makes it robust against perturbations. The method is demonstrated in an experiment made with a vibrating clarinet reed; phase modulations as large as 1000 radians have been measured.

  9. Measurement of rabbit eardrum vibration through stroboscopic digital holography

    Energy Technology Data Exchange (ETDEWEB)

    De Greef, Daniël; Dirckx, Joris J. J. [University of Antwerp, Laboratory of BioMedical Physics, Groenenborgerlaan 171, B-2020 Antwerp (Belgium)

    2014-05-27

    In this work, we present a setup for high-power single shot stroboscopic digital holography and demonstrate it in an application on rabbit eardrum vibration measurement. The setup is able to make full-field time-resolved measurements of vibrating surfaces with a precision in the nanometer range in a broad frequency range. The height displacement of the measured object is visualized over the entire surface as a function of time. Vibration magnitude and phase maps can be extracted from these data, the latter proving to be very useful to reveal phase delays across the surface. Such deviations from modal motion indicate energy losses due to internal damping, in contrast to purely elastic mechanics. This is of great interest in middle ear mechanics and finite element modelling. In our setup, short laser pulses are fired at selected instants within the surface vibration period and are recorded by a CCD camera. The timing of the pulses and the exposure of the camera are synchronized to the vibration phase by a microprocessor. The high-power frequency-doubled Nd:YAG laser produces pulses containing up to 5 mJ of energy, which is amply sufficient to record single-shot holograms. As the laser pulse length is 8 ns and the smallest time step of the trigger electronics is 1 μs, vibration measurements of frequencies up to 250 kHz are achievable through this method, provided that the maximum vibration amplitude exceeds a few nanometers. In our application, middle ear mechanics, measuring frequencies extend from 5 Hz to 20 kHz. The experimental setup will be presented, as well as results of measurements on a stretched circular rubber membrane and a rabbit's eardrum. Two of the challenges when measuring biological tissues, such as the eardrum, are low reflectivity and fast dehydration. To increase reflectivity, a coating is applied and to counteract the undesirable effects of tissue dehydration, the measurement setup and software have been optimized for speed without

  10. Overhead traveling crane vibration research using experimental wireless measuring system

    Directory of Open Access Journals (Sweden)

    Tomasz HANISZEWSKI

    2013-01-01

    Full Text Available The paper contains an operations and constructions description of theexperimental wireless measuring system for measuring accelerations in bridge cranes,based on PHIDGET 1056 sensors. Developed experimental research and measuringmethodology allows the use of the proposed wireless system on other cranesconstructions. The paper also shows examples of the results of vibration measurementsand FFT spectra, obtained on the basis of accelerations measurements.

  11. The CLARITY modular ambient health and wellness measurement platform

    OpenAIRE

    Walsh, Michael; O'Grady, Michael J; Dragone, Mauro; Tynan, Richard; Ruzzelli, Antonio G.; Barton, John,; O'Flynn, Brendan; O'Hare, G. M. P.; O Mathuna, Cian

    2010-01-01

    Emerging healthcare applications can benefit enormously from recent advances in pervasive technology and computing. This paper introduces the CLARITY Modular Ambient Health and Wellness Measurement Platform:, which is a heterogeneous and robust pervasive healthcare solution currently under development at the CLARITY Center for Sensor Web Technologies. This intelligent and context-aware platform comprises the Tyndall Wireless Sensor Network prototyping system, augmented with an agent-based mid...

  12. Ambient dose measurement in some CT departments in Khartoum State

    International Nuclear Information System (INIS)

    Computerized Tomography (CT) is now one of the most important radiological examinations world wide.The frequency of CT examinations is increasing rapidly from 2% of all radiological examinations in some countries a decade age to 10-15% now. During the imaging procedure, staff may expose to a significant dose. Therefore, ambient dose measurement is important in the shortage of regular personal monitoring in sudan. This study intended to evaluate the ambient dose at some CT departments (Medical Military hospital, Alamal National Hospital, Elnelin Diagnostic Center and Modern Medical Centre). These departments were equipped with daul, 16 and 64 multi detector CT machines. A survey meter (Radios) was used to measure ambient doses in three locations: Doors, Control Rooms and Adjacent Rooms. The ambient dose equivalent (scatter dose) was measured at various distances from the isocenter of the CT unit at various angles to establish isodose cartography. The mean and range of radiation at control room is 10.00-0.20 and mean (7.05μSv/hr,) reception 1.0-0 (0.40) and doors 4.00-100.00 (73.5) for height 1 meter above the ground. For height 2 meters at control room 0-10.00 (6,75), reception 0-90.00 (30) at door 9.00-90.00 (49.50). This study confirms that low levels of radiation dose are received by staff during CT imaging and these levels are within safe limits as prescribed by the national and international regulations. (Author)

  13. Ambient sesquiterpene concentration and its link to air ion measurements

    Directory of Open Access Journals (Sweden)

    B. Bonn

    2006-12-01

    Full Text Available Ambient air ion size distributions have been measured continuously at the Finnish boreal forest site in Hyytiälä since spring 2003. In general, these measurements show a maximum of air ions below 1.0 nm in diameter. But this physical characterization does not provide any information about the ion's chemical composition, which is one key question regarding the explanation of nucleation events observed. In this study we propose a link of the observed maximum of negative air ions between 0.56 and 0.75 nm to the so-called stabilised Criegee biradical, formed in the reaction of biogenic sesquiterpenes with ozone and predominantly destroyed by its reaction with ambient water vapour. Calculations of the electron and proton affinities of 120 kJ mol−1 (1.24 eV and of 960 kJ mol−1 support this link. Other possible candidates such as sulphuric acid derived clusters are unable to explain the observations made. By using this approach, we are able to calculate the ambient concentration of sesquiterpenes at the air ion instrument inlet with a high time resolution on the daily and seasonal scale. The estimated concentration is found to reveal the same seasonal pattern as emission measurements conducted at shoot level. As expected for biogenic VOCs, the concentration is obtained highest during summer (maximum values of about 100 pptv and smallest during winter (minimum less than 1 pptv. Because of the sesquiterpenes high reactivity and its low ambient concentrations, this approach can be a first step in understanding their emission and their impact on atmospheric chemistry in more detail. The findings presented are highly relevant for emission budgets too, since boreal forests are extended over large areas of the globe.

  14. Vibration measurement based on Multiple Self-Mixing Interferometry

    Science.gov (United States)

    Jiang, Chunlei; Zhang, Zihua; Li, Chengwei

    2016-05-01

    We propose a novel algorithm for Multiple Self-Mixing Interferometry (MSMI). The algorithm is able to measure nanometer scale vibration by the power spectrum analysis. In the paper, the principles of the method are introduced in detail. The experimental setup has been built. The validity of the proposed algorithm was confirmed by conducting a series of experimental measurements at different reflection times, feedback factors, and vibrational frequencies using PZT as a reference. Experimental results showed that the method can quickly demodulate parameters of vibration and good correspondence between theory and experiment. The proposed algorithm, thus, furnishes nanometer measurements with a very high resolution using a self-aligned, cost effective and compact experimental setup.

  15. Dynamic tire pressure sensor for measuring ground vibration.

    Science.gov (United States)

    Wang, Qi; McDaniel, James Gregory; Wang, Ming L

    2012-01-01

    This work presents a convenient and non-contact acoustic sensing approach for measuring ground vibration. This approach, which uses an instantaneous dynamic tire pressure sensor (DTPS), possesses the capability to replace the accelerometer or directional microphone currently being used for inspecting pavement conditions. By measuring dynamic pressure changes inside the tire, ground vibration can be amplified and isolated from environmental noise. In this work, verifications of the DTPS concept of sensing inside the tire have been carried out. In addition, comparisons between a DTPS, ground-mounted accelerometer, and directional microphone are made. A data analysis algorithm has been developed and optimized to reconstruct ground acceleration from DTPS data. Numerical and experimental studies of this DTPS reveal a strong potential for measuring ground vibration caused by a moving vehicle. A calibration of transfer function between dynamic tire pressure change and ground acceleration may be needed for different tire system or for more accurate application. PMID:23202206

  16. Dynamic Tire Pressure Sensor for Measuring Ground Vibration

    Directory of Open Access Journals (Sweden)

    Ming L. Wang

    2012-11-01

    Full Text Available This work presents a convenient and non-contact acoustic sensing approach for measuring ground vibration. This approach, which uses an instantaneous dynamic tire pressure sensor (DTPS, possesses the capability to replace the accelerometer or directional microphone currently being used for inspecting pavement conditions. By measuring dynamic pressure changes inside the tire, ground vibration can be amplified and isolated from environmental noise. In this work, verifications of the DTPS concept of sensing inside the tire have been carried out. In addition, comparisons between a DTPS, ground-mounted accelerometer, and directional microphone are made. A data analysis algorithm has been developed and optimized to reconstruct ground acceleration from DTPS data. Numerical and experimental studies of this DTPS reveal a strong potential for measuring ground vibration caused by a moving vehicle. A calibration of transfer function between dynamic tire pressure change and ground acceleration may be needed for different tire system or for more accurate application.

  17. A three-dimensional electret-based micro power generator for low-level ambient vibrational energy harvesting

    International Nuclear Information System (INIS)

    A novel three-dimensional (3D) electret-based micro power generator with multiple vibration modes has been developed, which is capable of converting low-level ambient kinetic energy to electrical energy. The device is based on a rotational symmetrical resonator which consists of a movable disc-shaped seismic mass suspended by three sets of spiral springs. Experimental analysis shows that the proposed generator operates at an out-of-plane direction at mode I of 66 Hz and two in-plane directions at mode II of 75 Hz and mode III of 78.5 Hz with a phase difference of about 90°. A corona localized charging method is also proposed that employs a shadow mask and multiple discharge needles for the production of micro-sized electret array. From tests conducted at an acceleration of 0.05 g, the prototype can generate a maximum power of 4.8 nW, 0.67 nW and 1.2 nW at vibration modes of I, II and III, respectively. These values correspond to the normalized power densities of 16 µW cm−3 g−2, 2.2 µW cm−3 g−2 and 4 µW cm−3 g−2, respectively. The results show that the generator can potentially offer an intriguing alternative for scavenging low-level ambient energy from 3D vibration sources. (paper)

  18. Frequency and damping ratio assessment of high-rise buildings using an Automatic Model-Based Approach applied to real-world ambient vibration recordings

    Science.gov (United States)

    Nasser, Fatima; Li, Zhongyang; Gueguen, Philippe; Martin, Nadine

    2016-06-01

    This paper deals with the application of the Automatic Model-Based Approach (AMBA) over actual buildings subjected to real-world ambient vibrations. In a previous paper, AMBA was developed with the aim of automating the estimation process of the modal parameters and minimizing the estimation error, especially that of the damping ratio. It is applicable over a single-channel record, has no parameters to be set, and no manual initialization phase. The results presented in this paper should be regarded as further documentation of the approach over real-world ambient vibration signals.

  19. Measurement of Piezoelectric Transformer Vibrations by Digital Holography

    Czech Academy of Sciences Publication Activity Database

    Psota, Pavel; Lédl, Vít; Doleček, Roman; Erhart, J.; Kopecký, V.

    2014-01-01

    Roč. 59, č. 9 (2014), s. 1962-1968. ISSN 0885-3010 R&D Projects: GA MŠk(CZ) ED2.1.00/03.0079 Institutional support: RVO:61389021 Keywords : digital holographic * ime-averaged holographic * small amplitude * vibrations amplitude measurement * piezoelectric transformers Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 1.512, year: 2014

  20. Novel Applications of Laser Doppler Vibration Measurements to Medical Imaging

    Science.gov (United States)

    Tabatabai, Habib; Oliver, David E.; Rohrbaugh, John W.; Papadopoulos, Christopher

    2013-06-01

    Laser Doppler Vibrometry (LDV) has been widely used in engineering applications involving non-contact vibration and sound measurements. This technique has also been used in some biomedical applications including hearing research. The detectable frequencies are in the range of near-DC to 1 GHz or higher. This paper reviews applications of LDV in biomedical engineering and proposes new medical imaging applications based on measuring surface vibrations of tissues and organs. Tests were conducted on human skin using single point and scanning laser vibrometers. These tests suggest that skin vibrations due to the forcing excitation from the heart can be used in imaging of blood flow. The results of these tests illustrate the potential of such vibration measurements in a variety of diagnostic medical imaging applications including blood flow/restrictions, real-time monitoring of blood pressure variations, wound healing, muscle movements, etc. The fact that the measurements can be conducted remotely (non-contact) is an important benefit that adds to the promise of this approach.

  1. Measuring ambient radon using a scintillating optical fiber bundle

    International Nuclear Information System (INIS)

    Complete text of publication follows. Several years ago a new approach to monitoring radon and its radioactive progeny using a bundle of scintillating optical fibers was introduced, and studies on the characteristics of this detector were reported. It was demonstrated that a bundle of thin optical fibers constructed from a scintillating glass could serve as a detector of radon in air by providing a large accessible surface area and a means of trapping and concentrating radon gas so as to increase the effective contact time between the radon and the scintillating material. We now report the first ambient radon measurements made with this detector. Details of the sensor construction will be supplied and diagrammed. Briefly, several thousand scintillating glass fibers are packed into a 6 mm i.d. quartz tube through which radon-laden ambient air is drawn. Light produced by the interaction of alpha particles from radon and its radioactive progeny is directed by a reflector onto a photomultiplier tube, and the resulting pulses are sorted and displayed by a multichannel scalar. The instrument has been used in laboratory studies, and in field measurements at a location in Slovenia with high radon levels. Radon was simultaneously monitored in the same location using an Alphaguard radon monitor, which is a commercial passive ionization chamber instrument. It was found that the fiber optic sensor detected ambient radon with a sensitivity of approximately 50 counts per minute per Bq per liter of air. Since the sensitive volume is only 1 ml. we conclude that significant concentration of radon on the the sensor is occurring. These results will be presented and discussed

  2. Surface Acoustic Wave Vibration Sensors for Measuring Aircraft Flutter

    Science.gov (United States)

    Wilson, William C.; Moore, Jason P.; Juarez, Peter D.

    2016-01-01

    Under NASA's Advanced Air Vehicles Program the Advanced Air Transport Technology (AATT) Project is investigating flutter effects on aeroelastic wings. To support that work a new method for measuring vibrations due to flutter has been developed. The method employs low power Surface Acoustic Wave (SAW) sensors. To demonstrate the ability of the SAW sensor to detect flutter vibrations the sensors were attached to a Carbon fiber-reinforced polymer (CFRP) composite panel which was vibrated at six frequencies from 1Hz to 50Hz. The SAW data was compared to accelerometer data and was found to resemble sine waves and match each other closely. The SAW module design and results from the tests are presented here.

  3. Measurement of Radiation Pressure in an Ambient Environment

    Science.gov (United States)

    Ma, Dakang; Garrett, Joseph; Munday, Jeremy

    2015-03-01

    Light has momentum and thus exerts ``radiation pressure'' when it is reflected or absorbed due to the conservation of momentum. Micromechanical transducers and oscillators are suitable for measurement and utilization of radiation pressure due to their high sensitivities. However, other light-induced mechanical deformations such as photothermal effects often obscure accurate measurements of radiation pressure in these systems. In this work, we investigate the radiation pressure and photothermal force on an uncoated silicon nitride microcantilever under illumination by a 660 nm laser in an ambient environment. To magnify the mechanical effects, the cantilever is driven optically from dc across its resonance frequency, and the amplitude and phase of its oscillation are acquired by an optical beam deflection method and a lockin amplifier. We show that radiation pressure and photothermal effects can be distinguished through the cantilever's frequency response. Furthermore, in a radiation pressure dominant regime, our measurement of the radiation force agrees quantitatively with the theoretical calculation.

  4. Fringe-free holographic measurements of large-amplitude vibrations.

    Science.gov (United States)

    Joud, F; Verpillat, F; Laloë, F; Atlan, M; Hare, J; Gross, M

    2009-12-01

    In the measurement of the amplitude of vibration of objects, holographic imaging techniques usually involve fringe counting; because of the limited resolution of the images, measurements of large amplitudes are not accessible. We demonstrate a technique that suppresses the necessity of fringe counting--frequency sideband imaging--where the order of the sideband is considered a marker of the amplitude. The measurement is completely local: no comparison with another reference point on the object is necessary. It involves a sharp variation of a signal, which makes it robust against perturbations. The method is demonstrated in an experiment made with a vibrating clarinet reed; phase modulations as large as 1000 rad have been measured. PMID:19953166

  5. Measurement of dynamic surface tension by mechanically vibrated sessile droplets

    Science.gov (United States)

    Iwata, Shuichi; Yamauchi, Satoko; Yoshitake, Yumiko; Nagumo, Ryo; Mori, Hideki; Kajiya, Tadashi

    2016-04-01

    We developed a novel method for measuring the dynamic surface tension of liquids using mechanically vibrated sessile droplets. Under continuous mechanical vibration, the shape of the deformed droplet was fitted by numerical analysis, taking into account the force balance at the drop surface and the momentum equation. The surface tension was determined by optimizing four parameters: the surface tension, the droplet's height, the radius of the droplet-substrate contact area, and the horizontal symmetrical position of the droplet. The accuracy and repeatability of the proposed method were confirmed using drops of distilled water as well as viscous aqueous glycerol solutions. The vibration frequency had no influence on surface tension in the case of pure liquids. However, for water-soluble surfactant solutions, the dynamic surface tension gradually increased with vibration frequency, which was particularly notable for low surfactant concentrations slightly below the critical micelle concentration. This frequency dependence resulted from the competition of two mechanisms at the drop surface: local surface deformation and surfactant transport towards the newly generated surface.

  6. Measurement of dynamic surface tension by mechanically vibrated sessile droplets.

    Science.gov (United States)

    Iwata, Shuichi; Yamauchi, Satoko; Yoshitake, Yumiko; Nagumo, Ryo; Mori, Hideki; Kajiya, Tadashi

    2016-04-01

    We developed a novel method for measuring the dynamic surface tension of liquids using mechanically vibrated sessile droplets. Under continuous mechanical vibration, the shape of the deformed droplet was fitted by numerical analysis, taking into account the force balance at the drop surface and the momentum equation. The surface tension was determined by optimizing four parameters: the surface tension, the droplet's height, the radius of the droplet-substrate contact area, and the horizontal symmetrical position of the droplet. The accuracy and repeatability of the proposed method were confirmed using drops of distilled water as well as viscous aqueous glycerol solutions. The vibration frequency had no influence on surface tension in the case of pure liquids. However, for water-soluble surfactant solutions, the dynamic surface tension gradually increased with vibration frequency, which was particularly notable for low surfactant concentrations slightly below the critical micelle concentration. This frequency dependence resulted from the competition of two mechanisms at the drop surface: local surface deformation and surfactant transport towards the newly generated surface. PMID:27131706

  7. Ambient solar UVR measurement : evaluation of currently available detectors

    International Nuclear Information System (INIS)

    Full text: The Australian Radiation Laboratory (ARL) has maintained a solar ultraviolet radiation (UVR) measurement network covering numerous sites around Australia and Antarctica since the late 1980's using a variety of radiometric detectors. Each datalogger system generally has a UVB (280-315 nm) detector, UVR (290-390 nm) detector and a detector which attempts to measure biologically effective UVR (either an International Light actinic detector or a Solar Light Model 501 UV-Biometer). The network, which covers all the capital cities is underpinned by a double monochromator spectroradiometer and calibrated standard lamps at ARL. This allows each radiometer to be individually calibrated against simultaneous spectral measurements of solar UVR. Concern over ozone depletion and the possibility of a concomitant increase in solar UVB at the earth's surface has lead to a rapid increase in the number of UW measurement systems deployed worldwide. The 501 UV- Biometer is now used extensively on a global basis and it is important that its performance characteristics are known. The ARL network covers a very wide latitude and longitude band, with conditions ranging from tropical to Antarctic. Prior to installation all detectors were intercompared at ARL although complete characterisation was not possible. Analysis of the data collected from the network has commenced and has begun to highlight the strengths and weaknesses of the UVR detectors. Data from the network provides input for the daily UVB chart for television, for UVR personal exposure studies and for UVB climatology. Results for Melbourne and Brisbane will be presented and these show the importance of solar zenith angle, atmospheric ozone and cloud in determining levels of ambient UVB. Recently a 501 W-Biometer was used in separate short-term measurement campaigns in Finland and Townsville. Results were inconsistent with calibrations performed at ARL and subsequent laboratory characterisations revealed a significant

  8. Bridge health monitoring system based on vibration measurements

    OpenAIRE

    Ntotsios, Evangelos; Papadimitriou, Costas; Panetsos, Panagiotis; Karaiskos, Grigorios; Perros, Kyriakos; Perdikaris, Filippos

    2009-01-01

    A bridge health monitoring system is presented based on vibration measurements collected from a network of acceleration sensors. Sophisticated structural identification methods, combining information from the sensor network with the theoretical information built into a finite element model for simulating bridge behaviour, are incorporated into the system in order to monitor structural condition, track structural changes and identify the location, type and extent of damage. This work starts wi...

  9. Customized DSP-based vibration measurement for wind turbines

    Energy Technology Data Exchange (ETDEWEB)

    LaWhite, N.E.; Cohn, K.E. [Second Wind Inc., Somerville, MA (United States)

    1996-12-31

    As part of its Advanced Distributed Monitoring System (ADMS) project funded by NREL, Second Wind Inc. is developing a new vibration measurement system for use with wind turbines. The system uses low-cost accelerometers originally designed for automobile airbag crash-detection coupled with new software executed on a Digital Signal Processor (DSP) device. The system is envisioned as a means to monitor the mechanical {open_quotes}health{close_quotes} of the wind turbine over its lifetime. In addition the system holds promise as a customized emergency vibration detector. The two goals are very different and it is expected that different software programs will be executed for each function. While a fast Fourier transform (FFT) signature under given operating conditions can yield much information regarding turbine condition, the sampling period and processing requirements make it inappropriate for emergency condition monitoring. This paper briefly reviews the development of prototype DSP and accelerometer hardware. More importantly, it reviews our work to design prototype vibration alarm filters. Two-axis accelerometer test data from the experimental FloWind vertical axis wind turbine is analyzed and used as a development guide. Two levels of signal processing are considered. The first uses narrow band pre-processing filters at key fundamental frequencies such as the 1P, 2P and 3P. The total vibration energy in each frequency band is calculated and evaluated as a possible alarm trigger. In the second level of signal processing, the total vibration energy in each frequency band is further decomposed using the two-axis directional information. Directional statistics are calculated to differentiate between linear translations and circular translations. After analyzing the acceleration statistics for normal and unusual operating conditions, the acceleration processing system described could be used in automatic early detection of fault conditions. 9 figs.

  10. VIBRATION MEASUREMENTS IN A RHIC QUADRUPOLE AT CRYOGENIC TEMPERATURES.

    Energy Technology Data Exchange (ETDEWEB)

    JAIN, A.; AYDIN, S.; HE, P.; ANERELLA, M.; GANETIS, G.; HARRISON, M.; PARKER, B.; PLATE, S.

    2005-10-17

    One of the concerns in using compact superconducting magnets in the final focus region of the ILC is the influence of the cryogen flow on the vibration characteristics. As a first step towards characterizing such motion at nanometer levels, a project was undertaken at BNL to measure the vibrations in a spare RHIC quadrupole under cryogenic conditions. Given the constraints of cryogenic operation, and limited space available, it was decided to use a dual head laser Doppler vibrometer for this work. The performance of the laser vibrometer was tested in a series of room temperature tests and compared with results from Mark L4 geophones. The laser system was then used to measure the vibration of the cold mass of the quadrupole with respect to the outside warm enclosure. These measurements were carried out both with and without the flow of cold helium through the magnet. The results indicate only a minor increase in motion in the horizontal direction (where the cold mass is relatively free to move).

  11. Development of remote vibration measurement technique through turbulent media

    International Nuclear Information System (INIS)

    The effect of wavefront distortion of laser beam of a LDV(Laser Doppler Vibrometer) in the turbulence media was investigated for application of adaptive optics to LDV. The high-speed tip/tilt adaptive optics system and closed-loop steering algorithm were developed for real-time correction of the direction fluctuation of the laser beam of LDV. The measuring performance of the LDV was improved when the steering system was applied to LDV at the vibration frequency range of 10 Hz - 30 Hz. The high-speed Shack-Hartmann wavefront sensor(400 Hz) was developed to measure the performance of the LDV due to wavefront distortion. The wavefront distortion due to the turbulence media induced low visibility and degraded the performance of the vibrometer. From the experiments, when the wavefront distortion is above 2 wavelengths in the cross section of the laser beam(dia. 20 mm), the vibration signal from laser vibrometer was severely degraded. When the wavefront distortion is smaller than one wave, the vibration signal was good. From the this research, high-speed closed-loop tip/tilt control technique of the laser beam was developed and applied to the laser metrology area. In the future, the adaptive optics system for wavefront correction will be applied to other research area

  12. Vibrational spectra of nanowires measured using laser doppler vibrometry and STM studies of epitaxial graphene : an LDRD fellowship report.

    Energy Technology Data Exchange (ETDEWEB)

    Biedermann, Laura Butler

    2009-09-01

    A few of the many applications for nanowires are high-aspect ratio conductive atomic force microscope (AFM) cantilever tips, force and mass sensors, and high-frequency resonators. Reliable estimates for the elastic modulus of nanowires and the quality factor of their oscillations are of interest to help enable these applications. Furthermore, a real-time, non-destructive technique to measure the vibrational spectra of nanowires will help enable sensor applications based on nanowires and the use of nanowires as AFM cantilevers (rather than as tips for AFM cantilevers). Laser Doppler vibrometry is used to measure the vibration spectra of individual cantilevered nanowires, specifically multiwalled carbon nanotubes (MWNTs) and silver gallium nanoneedles. Since the entire vibration spectrum is measured with high frequency resolution (100 Hz for a 10 MHz frequency scan), the resonant frequencies and quality factors of the nanowires are accurately determined. Using Euler-Bernoulli beam theory, the elastic modulus and spring constant can be calculated from the resonance frequencies of the oscillation spectrum and the dimensions of the nanowires, which are obtained from parallel SEM studies. Because the diameters of the nanowires studied are smaller than the wavelength of the vibrometer's laser, Mie scattering is used to estimate the lower diameter limit for nanowires whose vibration can be measured in this way. The techniques developed in this thesis can be used to measure the vibrational spectra of any suspended nanowire with high frequency resolution Two different nanowires were measured - MWNTs and Ag{sub 2}Ga nanoneedles. Measurements of the thermal vibration spectra of MWNTs under ambient conditions showed that the elastic modulus, E, of plasma-enhanced chemical vapor deposition (PECVD) MWNTs is 37 {+-} 26 GPa, well within the range of E previously reported for CVD-grown MWNTs. Since the Ag{sub 2}Ga nanoneedles have a greater optical scattering efficiency than

  13. Direct Measurements of Pore Fluid Density by Vibrating Tube Densimetry

    Energy Technology Data Exchange (ETDEWEB)

    Gruszkiewicz, Miroslaw {Mirek} S [ORNL; Rother, Gernot [ORNL; Wesolowski, David J [ORNL; Cole, David R [ORNL; Wallacher, Dirk [Helmholtz-Zentrum Berlin

    2012-01-01

    The densities of pore-confined fluids were measured for the first time by means of a vibrating tube method. Isotherms of total adsorption capacity were measured directly making the method complementary to the conventional gravimetric or volumetric/piezometric adsorption techniques, which yield the excess adsorption (the Gibbsian surface excess). A custom-made high-pressure, high-temperature vibrating tube densimeter (VTD) was used to measure the densities of subcritical and supercritical propane (between 35 C and 97 C) and supercritical carbon dioxide (between 32 C and 50 C) saturating hydrophobic silica aerogel (0.2 g/cm3, 90% porosity) synthesized inside Hastelloy U-tubes. Additionally, excess adsorption isotherms for supercritical CO2 and the same porous solid were measured gravimetrically using a precise magnetically-coupled microbalance. Pore fluid densities and total adsorption isotherms increased monotonically with increasing density of the bulk fluid, in contrast to excess adsorption isotherms, which reached a maximum at a subcritical density of the bulk fluid, and then decreased towards zero or negative values at supercritical densities. Compression of the confined fluid significantly beyond the density of the bulk liquid at the same temperature was observed at subcritical temperatures. The features of the isotherms of confined fluid density are interpreted to elucidate the observed behavior of excess adsorption. The maxima of excess adsorption were found to occur below the critical density of the bulk fluid at the conditions corresponding to the beginning of the plateau of total adsorption, marking the end of the transition of pore fluid to a denser, liquid-like pore phase. The results for propane and carbon dioxide showed similarity in the sense of the principle of corresponding states. No measurable effect of pore confinement on the liquid-vapor critical point was found. Quantitative agreement was obtained between excess adsorption isotherms determined

  14. Honeybee Colony Vibrational Measurements to Highlight the Brood Cycle.

    Directory of Open Access Journals (Sweden)

    Martin Bencsik

    Full Text Available Insect pollination is of great importance to crop production worldwide and honey bees are amongst its chief facilitators. Because of the decline of managed colonies, the use of sensor technology is growing in popularity and it is of interest to develop new methods which can more accurately and less invasively assess honey bee colony status. Our approach is to use accelerometers to measure vibrations in order to provide information on colony activity and development. The accelerometers provide amplitude and frequency information which is recorded every three minutes and analysed for night time only. Vibrational data were validated by comparison to visual inspection data, particularly the brood development. We show a strong correlation between vibrational amplitude data and the brood cycle in the vicinity of the sensor. We have further explored the minimum data that is required, when frequency information is also included, to accurately predict the current point in the brood cycle. Such a technique should enable beekeepers to reduce the frequency with which visual inspections are required, reducing the stress this places on the colony and saving the beekeeper time.

  15. Experimental Study on the Measurement of Water Bottom Vibration Induced by Underwater Drilling Blasting

    OpenAIRE

    Gu Wenbin; Chen Jianghai; Wang Zhenxiong; Wang Zhihua; Liu Jianqing; Lu Ming

    2015-01-01

    Due to the lack of proper instrumentations and the difficulties in underwater measurements, the studies about water bottom vibration induced by underwater drilling blasting are seldom reported. In order to investigate the propagation and attenuation laws of blasting induced water bottom vibration, a water bottom vibration monitor was developed with consideration of the difficulties in underwater measurements. By means of this equipment, the actual water bottom vibration induced by underwater ...

  16. Ambient Intelligence Application Based on Environmental Measurements Performed with an Assistant Mobile Robot

    Directory of Open Access Journals (Sweden)

    Dani Martinez

    2014-03-01

    Full Text Available This paper proposes the use of an autonomous assistant mobile robot in order to monitor the environmental conditions of a large indoor area and develop an ambient intelligence application. The mobile robot uses single high performance embedded sensors in order to collect and geo-reference environmental information such as ambient temperature, air velocity and orientation and gas concentration. The data collected with the assistant mobile robot is analyzed in order to detect unusual measurements or discrepancies and develop focused corrective ambient actions. This paper shows an example of the measurements performed in a research facility which have enabled the detection and location of an uncomfortable temperature profile inside an office of the research facility. The ambient intelligent application has been developed by performing some localized ambient measurements that have been analyzed in order to propose some ambient actuations to correct the uncomfortable temperature profile.

  17. The correction of vibration in frequency scanning interferometry based absolute distance measurement system for dynamic measurements

    Science.gov (United States)

    Lu, Cheng; Liu, Guodong; Liu, Bingguo; Chen, Fengdong; Zhuang, Zhitao; Xu, Xinke; Gan, Yu

    2015-10-01

    Absolute distance measurement systems are of significant interest in the field of metrology, which could improve the manufacturing efficiency and accuracy of large assemblies in fields such as aircraft construction, automotive engineering, and the production of modern windmill blades. Frequency scanning interferometry demonstrates noticeable advantages as an absolute distance measurement system which has a high precision and doesn't depend on a cooperative target. In this paper , the influence of inevitable vibration in the frequency scanning interferometry based absolute distance measurement system is analyzed. The distance spectrum is broadened as the existence of Doppler effect caused by vibration, which will bring in a measurement error more than 103 times bigger than the changes of optical path difference. In order to decrease the influence of vibration, the changes of the optical path difference are monitored by a frequency stabilized laser, which runs parallel to the frequency scanning interferometry. The experiment has verified the effectiveness of this method.

  18. Power spectral density function and spatial autocorrelation of the ambient vibration full-wavefield generated by a distribution of spatially correlated surface sources

    Science.gov (United States)

    Lunedei, Enrico; Albarello, Dario

    2016-03-01

    Synthetic dispersion curves are here computed in the frame of an ambient-vibration full-wavefield model, which relies on the description of both ambient-vibration ground displacement and its sources as stochastic fields defined on the Earth's surface, stationary in time and homogeneous in space. In this model, previously developed for computing synthetic Horizontal-to-Vertical Spectral Ratio curves, the power spectral density function and the spatial autocorrelation of the displacement are naturally described as functions of the power spectral density function of the generating forces and of the subsoil properties (via the relevant Green's function), by also accounting for spatial correlation of these forces. Dispersion curves are computed from the displacement power spectral density function and from the spatial autocorrelation according with the well-known f-k and SPAC techniques, respectively. Two examples illustrate the way this new ambient-vibration model works, showing its possible use in better understanding the role of the surface waves in forming the dispersion curves, as well as its capability to capture some remarkable experimental findings.

  19. Application of Story-wise Shear Building Identification Method to Actual Ambient Vibration

    Directory of Open Access Journals (Sweden)

    Kohei eFujita

    2015-02-01

    Full Text Available A sophisticated and smart story stiffness System Identification (SI method for a shear building model is applied to a full-scale building frame subjected to micro-tremors. The advantageous and novel feature is that not only the modal parameters, such as natural frequencies and damping ratios, but also the physical model parameters, such as story stiffnesses and damping coefficients, can be identified using micro-tremors. While the building responses to earthquake ground motions are necessary in the previous SI method, it is shown in this paper that the micro-tremor measurements in a full-scale 5 story building frame can be used for identification within the same framework. The SI using micro-tremor measurements leads to the enhanced usability of the previously proposed story-wise shear building identification method. The degree of ARX models and cut-off frequencies of band-pass filter are determined to derive reliable results.

  20. Low temperature vibrating reed measurements of Zr based metallic glasses

    International Nuclear Information System (INIS)

    The low temperature thermal and acoustic behavior of glasses, dielectric or metallic, is dominated by two-level systems caused by the tunneling of small groups of atoms between two almost equivalent sites. Specific distributions of the relevant parameters are suggested by the well established tunneling model. Acoustic measurements of various superconducting metallic glasses demonstrate that conduction electrons not only drastically change the dynamics of tunneling systems as compared to insulating glasses but also seem to influence the apparent density of states of the tunneling systems. The advent of bulk metallic glasses (BMG) considerably facilitates acoustic experiments. Our vibrating reed measurements of the BMG Zr59Ti3Cu20Ni8Al10 and the splat cooled metallic glass Zr65Al7.5Cu27.5 reveal interesting differences in the internal friction which presumably reflect the quite different cooling rates in the preparation procedures of the two metallic glasses.

  1. Measurement of whole-body vibration in taxi drivers.

    Science.gov (United States)

    Funakoshi, Mitsuhiko; Taoda, Kazushi; Tsujimura, Hiroji; Nishiyama, Katsuo

    2004-03-01

    In a previous epidemiological study we reported that the prevalence (45.8%) of low-back pain (LBP) and the two-year incidence (25.9%) of LBP in 284 male taxi drivers in Japan was comparable with rates reported for other occupational drivers in which LBP frequently occurs. LBP was significantly related with the level of uncomfortable road vibrations, and, importantly, increased with total mileage. The aim of this study was to measure whole-body vibration (WBV) on the driver's seat pan of 12 taxis operating under actual working conditions. The results were evaluated according to the health guidelines in International Standard ISO 2631-1:1997. Finally, the relation between total mileage and WBV was investigated. The majority of the frequency-weighted r.m.s. accelerations of the taxis fell into the "potential health risks" zone, under ISO 2631-1:1997. It was clear that the taxi drivers were exposed to serious WBV magnitudes. Therefore, occupational health and safety management should be carried out to help prevent adverse health effects in taxi drivers. In particular, reduction of WBV in taxis and shortening of driving time to reduce duration of WBV exposure should be considered. Moreover, because many taxi drivers work 18 h every other day, the shortening of working hours and taking of rest breaks while working should be considered. Frequency-weighted r.m.s. accelerations of taxis had a tendency to decrease as total mileage increased. The relation between total mileage and WBV should be investigated by taking measurements on the floor and the back rest in addition to the seat pan. PMID:15090686

  2. Vibration measurements of high-heat-load monochromators for DESY PETRA III extension

    International Nuclear Information System (INIS)

    Vibration measurements of a cryocooled double-crystal monochromator are presented. The origins of the vibrations are identified. The minimum achieved vibration of the relative pitch between the two crystals is 48 nrad RMS and the minimum achieved absolute vibration of the second crystal is 82 nrad RMS. The requirement for vibrational stability of beamline optics continues to evolve rapidly to comply with the demands created by the improved brilliance of the third-generation low-emittance storage rings around the world. The challenge is to quantify the performance of the instrument before it is installed at the beamline. In this article, measurement techniques are presented that directly and accurately measure (i) the relative vibration between the two crystals of a double-crystal monochromator (DCM) and (ii) the absolute vibration of the second-crystal cage of a DCM. Excluding a synchrotron beam, the measurements are conducted under in situ conditions, connected to a liquid-nitrogen cryocooler. The investigated DCM utilizes a direct-drive (no gearing) goniometer for the Bragg rotation. The main causes of the DCM vibration are found to be the servoing of the direct-drive goniometer and the flexibility in the crystal cage motion stages. It is found that the investigated DCM can offer relative pitch vibration down to 48 nrad RMS (capacitive sensors, 0–5 kHz bandwidth) and absolute pitch vibration down to 82 nrad RMS (laser interferometer, 0–50 kHz bandwidth), with the Bragg axis brake engaged

  3. Vibration measurements of high-heat-load monochromators for DESY PETRA III extension

    Energy Technology Data Exchange (ETDEWEB)

    Kristiansen, Paw, E-mail: paw.kristiansen@fmb-oxford.com [FMB Oxford Ltd, Unit 1 Ferry Mills, Oxford OX2 0ES (United Kingdom); Horbach, Jan; Döhrmann, Ralph; Heuer, Joachim [DESY, Deutsches Elektronen-Synchrotron Hamburg, Notkestrasse 85, 22607 Hamburg (Germany)

    2015-05-09

    Vibration measurements of a cryocooled double-crystal monochromator are presented. The origins of the vibrations are identified. The minimum achieved vibration of the relative pitch between the two crystals is 48 nrad RMS and the minimum achieved absolute vibration of the second crystal is 82 nrad RMS. The requirement for vibrational stability of beamline optics continues to evolve rapidly to comply with the demands created by the improved brilliance of the third-generation low-emittance storage rings around the world. The challenge is to quantify the performance of the instrument before it is installed at the beamline. In this article, measurement techniques are presented that directly and accurately measure (i) the relative vibration between the two crystals of a double-crystal monochromator (DCM) and (ii) the absolute vibration of the second-crystal cage of a DCM. Excluding a synchrotron beam, the measurements are conducted under in situ conditions, connected to a liquid-nitrogen cryocooler. The investigated DCM utilizes a direct-drive (no gearing) goniometer for the Bragg rotation. The main causes of the DCM vibration are found to be the servoing of the direct-drive goniometer and the flexibility in the crystal cage motion stages. It is found that the investigated DCM can offer relative pitch vibration down to 48 nrad RMS (capacitive sensors, 0–5 kHz bandwidth) and absolute pitch vibration down to 82 nrad RMS (laser interferometer, 0–50 kHz bandwidth), with the Bragg axis brake engaged.

  4. Multi-purpose whole-body vibration measurement and evaluation system

    OpenAIRE

    Ruotsalainen, Keijo

    2011-01-01

    The minimization of health risks associated with regular and continuous exposure to mechanical vibration has been taken into account in the EU directive 2002/44/EC. Employers are responsible for estimating the daily vibration exposure of an employee based, preferably on measurements. The objective of this article is to describe a comprehensive system designed for long-term whole-body vibration measurements as well as for serving research related needs. The system architecture comprises wirele...

  5. Measuring correlated electronic and vibrational spectral dynamics using line shapes in two-dimensional electronic-vibrational spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, Nicholas H. C.; Dong, Hui; Oliver, Thomas A. A.; Fleming, Graham R., E-mail: grfleming@lbl.gov [Department of Chemistry, University of California, Berkeley, California 94720 (United States); Physical Biosciences Division, Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States); Kavli Energy NanoSciences Institute at Berkeley, Berkeley, California 94720 (United States)

    2015-05-07

    Two-dimensional electronic-vibrational (2DEV) spectroscopy is an experimental technique that shows great promise in its ability to provide detailed information concerning the interactions between the electronic and vibrational degrees of freedom in molecular systems. The physical quantities 2DEV is particularly suited for measuring have not yet been fully determined, nor how these effects manifest in the spectra. In this work, we investigate the use of the center line slope of a peak in a 2DEV spectrum as a measure of both the dynamic and static correlations between the electronic and vibrational states of a dye molecule in solution. We show how this center line slope is directly related to the solvation correlation function for the vibrational degrees of freedom. We also demonstrate how the strength with which the vibration on the electronic excited state couples to its bath can be extracted from a set of 2DEV spectra. These analytical techniques are then applied to experimental data from the laser dye 3,3′-diethylthiatricarbocyanine iodide in deuterated chloroform, where we determine the lifetime of the correlation between the electronic transition frequency and the transition frequency for the backbone C = C stretch mode to be ∼1.7 ps. Furthermore, we find that on the electronic excited state, this mode couples to the bath ∼1.5 times more strongly than on the electronic ground state.

  6. Measuring correlated electronic and vibrational spectral dynamics using line shapes in two-dimensional electronic-vibrational spectroscopy.

    Science.gov (United States)

    Lewis, Nicholas H C; Dong, Hui; Oliver, Thomas A A; Fleming, Graham R

    2015-05-01

    Two-dimensional electronic-vibrational (2DEV) spectroscopy is an experimental technique that shows great promise in its ability to provide detailed information concerning the interactions between the electronic and vibrational degrees of freedom in molecular systems. The physical quantities 2DEV is particularly suited for measuring have not yet been fully determined, nor how these effects manifest in the spectra. In this work, we investigate the use of the center line slope of a peak in a 2DEV spectrum as a measure of both the dynamic and static correlations between the electronic and vibrational states of a dye molecule in solution. We show how this center line slope is directly related to the solvation correlation function for the vibrational degrees of freedom. We also demonstrate how the strength with which the vibration on the electronic excited state couples to its bath can be extracted from a set of 2DEV spectra. These analytical techniques are then applied to experimental data from the laser dye 3,3'-diethylthiatricarbocyanine iodide in deuterated chloroform, where we determine the lifetime of the correlation between the electronic transition frequency and the transition frequency for the backbone C = C stretch mode to be ∼1.7 ps. Furthermore, we find that on the electronic excited state, this mode couples to the bath ∼1.5 times more strongly than on the electronic ground state. PMID:25956093

  7. Measuring Work Functions Of "Dirty" Surfaces With A Vibrating Capacitive Probe

    Science.gov (United States)

    Yost, William T.

    1995-01-01

    Apparatus measures work function of possibly contaminated surface of specimen of metal or other electrically conductive material. Measures work function of specimen indirectly, by vibrating capacitive measurement of contact potential. Work function of specimen affected by microstructure and by contamination.

  8. Study of undulator magnetic field measurement using vibrating wire method

    International Nuclear Information System (INIS)

    A test accelerator for a terahertz source project (t-ACTS) has been progressed at the Electron Light Science Centre, Tohoku University, in which a generation of intense coherent terahertz radiation from the very short electron bunch will be demonstrated. A narrow-band coherent terahertz radiation using an undulator has been considered to be implemented. We have constructed a planer undulator that is basically a Halbach type composed of permanent magnet blocks. The period length of the undulator and the number of periods are 100 mm and 25, respectively. The vibrating wire method is studied to measure the periodic magnetic field of the undulator. A thin copper-beryllium wire is placed on beam axis in the undulator, and an AC current flow is applied in the wire. By measuring amplitudes and phases of standing waves excited on the wire by the Lorentz force between AC current and magnetic field, we can reconstruct the magnetic field distribution along the wire. We discuss relations between reproducibility of the undulator field and the mode harmonics number used for the reconstruction of undulator field. (author)

  9. Wide-field heterodyne interferometric vibrometry for two-dimensional surface vibration measurement

    Science.gov (United States)

    Choi, Samuel; Maruyama, Yuta; Suzuki, Takamasa; Nin, Fumiaki; Hibino, Hiroshi; Sasaki, Osami

    2015-12-01

    Conventional laser Doppler vibrometry and heterodyne interferometry suffer during the simultaneous measurement of the spatial distribution of vibration parameters such as the amplitude, frequency and phase in a wide field of view. Although demand is increasing for methods that can measure vibrations over a wide field of view for a wide range of applications from industrial product inspections to biological measurements, full-field (FF) techniques for high-speed vibration measurements without a spatial scan are untapped. We propose a new method for high-speed FF vibration measurement that can easily be combined with profilometry and tomographic interferometry using a conventional CCD or CMOS camera. In principle, the measurable vibration frequency is unrestricted because the heterodyne signal produced by the modulated interferogram can be controlled to accommodate the CCD frame rate. The validity of the proposed method and the measurement accuracy of the spatial vibration amplitude were evaluated through simulations and experiments. In experiments, the spatial vibration parameters of a mirror vibrated at a frequency of 1 kHz and amplitude of approximately 5-65 nm were successfully measured with a spatial fluctuation of 3%-6.5%.

  10. Simple method for measuring vibration amplitude of high power airborne ultrasonic transducer: using thermo-couple.

    Science.gov (United States)

    Saffar, Saber; Abdullah, Amir

    2014-03-01

    Vibration amplitude of transducer's elements is the influential parameters in the performance of high power airborne ultrasonic transducers to control the optimum vibration without material yielding. The vibration amplitude of elements of provided high power airborne transducer was determined by measuring temperature of the provided high power airborne transducer transducer's elements. The results showed that simple thermocouples can be used both to measure the vibration amplitude of transducer's element and an indicator to power transmission to the air. To verify our approach, the power transmission to the air has been investigated by other common method experimentally. The experimental results displayed good agreement with presented approach. PMID:24246149

  11. Fluid flow measurements by means of vibration monitoring

    Science.gov (United States)

    Campagna, Mauro M.; Dinardo, Giuseppe; Fabbiano, Laura; Vacca, Gaetano

    2015-11-01

    The achievement of accurate fluid flow measurements is fundamental whenever the control and the monitoring of certain physical quantities governing an industrial process are required. In that case, non-intrusive devices are preferable, but these are often more sophisticated and expensive than those which are more common (such as nozzles, diaphrams, Coriolis flowmeters and so on). In this paper, a novel, non-intrusive, simple and inexpensive methodology is presented to measure the fluid flow rate (in a turbulent regime) whose physical principle is based on the acquisition of transversal vibrational signals induced by the fluid itself onto the pipe walls it is flowing through. Such a principle of operation would permit the use of micro-accelerometers capable of acquiring and transmitting the signals, even by means of wireless technology, to a control room for the monitoring of the process under control. A possible application (whose feasibility will be investigated by the authors in a further study) of this introduced technology is related to the employment of a net of micro-accelerometers to be installed on pipeline networks of aqueducts. This apparatus could lead to the faster and easier detection and location of possible leaks of fluid affecting the pipeline network with more affordable costs. The authors, who have previously proven the linear dependency of the acceleration harmonics amplitude on the flow rate, here discuss an experimental analysis of this functional relation with the variation in the physical properties of the pipe in terms of its diameter and constituent material, to find the eventual limits to the practical application of the measurement methodology.

  12. Analysis of In-Flight Vibration Measurements from Helicopter Transmissions

    Science.gov (United States)

    Mosher, Marianne; Huff, Ed; Barszcz

    2004-01-01

    In-flight vibration measurements from the transmission of an OH-58C KIOWA are analyzed. In order to understand the effect of normal flight variation on signal shape, the first gear mesh components of the planetary gear system and bevel gear are studied in detail. Systematic patterns occur in the amplitude and phase of these signal components with implications for making time synchronous averages and interpreting gear metrics in flight. The phase of the signal component increases as the torque increases; limits on the torque range included in a time synchronous average may now be selected to correspond to phase change limits on the underlying signal. For some sensors and components, an increase in phase variation and/or abrupt change in the slope of the phase dependence on torque are observed in regions of very low amplitude of the signal component. A physical mechanism for this deviation is postulated. Time synchronous averages should not be constructed in torque regions with wide phase variation.

  13. New System for Measuring Impact Vibration on Floor Decking Sheets

    Directory of Open Access Journals (Sweden)

    Carlos Moron

    2014-12-01

    Full Text Available Currently, there is a narrow range of materials that are used as attenuators of impact noise and building vibrations. Materials used in construction, such as elastic materials, must meet the requirement of having very low elastic modulus values. For the determination of the material’s elastic modulus and the acoustic insulation of the same, costly and difficult to execute testing is required. The present paper exposes an alternative system that is simpler and more economic, consisting of a predefined striking device and a sensor able to determine, once the strike is produced, the energy absorbed by the plate. After the impact is produced, the plate undergoes a deformation, which absorbs part of the energy, the remaining part being transmitted to the slab and, at the same time, causing induced airborne noise in the adjoining room. The plate absorbs the power through its own deformation, which is measured with the help of a capacitive sensor. This way, it would be possible to properly define the geometry of the plates, after the execution of the test, and we will try to establish a relationship between the values proposed in this research and the acoustic behavior demanded by the Spanish standards.

  14. Active low-frequency vertical vibration isolation system for precision measurements

    Science.gov (United States)

    Wu, Kang; Li, Gang; Hu, Hua; Wang, Lijun

    2016-06-01

    Low-frequency vertical vibration isolation systems play important roles in precision measurements to reduce seismic and environmental vibration noise. Several types of active vibration isolation systems have been developed. However, few researches focus on how to optimize the test mass install position in order to improve the vibration transmissibility. An active low-frequency vertical vibration isolation system based on an earlier instrument, the Super Spring, is designed and implemented. The system, which is simple and compact, consists of two stages: a parallelogram-shaped linkage to ensure vertical motion, and a simple spring-mass system. The theoretical analysis of the vibration isolation system is presented, including terms erroneously ignored before. By carefully choosing the mechanical parameters according to the above analysis and using feedback control, the resonance frequency of the system is reduced from 2.3 to 0.03 Hz, a reduction by a factor of more than 75. The vibration isolation system is installed as an inertial reference in an absolute gravimeter, where it improved the scatter of the absolute gravity values by a factor of 5. The experimental results verifies the improved performance of the isolation system, making it particularly suitable for precision experiments. The improved vertical vibration isolation system can be used as a prototype for designing high-performance active vertical isolation systems. An improved theoretical model of this active vibration isolation system with beam-pivot configuration is proposed, providing fundamental guidelines for vibration isolator design and assembling.

  15. 环境振动下的钢管混凝土拱桥试验与分析%Ambient Vibration Testing and Analysis of Concrete Filled Steel Tube Arch Bridge

    Institute of Scientific and Technical Information of China (English)

    王立宪; 狄生奎; 刘云帅; 花尉攀

    2011-01-01

    环境振动试验是检测大型桥梁结构的主要方法,检测得到的模态参数是判定桥梁健康状况的重要依据.本文基于随机振动理论,从雁滩黄河大桥在环境激励下获得的加速度测试信号中提取高信噪比的响应信号,采用频域峰值法和时域随机子空间法识别得到了该桥的固有频率、阻尼比和振型等模态参数,并与有限元模型计算结果进行了对比,验证了识别结果的可靠性,结果可作为该桥的损伤检测、使用状态评估和健康监测的基础.%Ambient vibration test is the main method of detecting a large bridge structure, Modal parameters is important to determine the health status of the bridge. Based on random vibration theory, as a high signal-to-noise ratio response,virtual response is obtained from the measured acceleration signal of Yantan Yellow River Bridge of Lanzhou under ambient excitation. Yantan Yellow River bridge's modal parameters, such as natural frequency, damping ratio and mode of vibration, are identified by using the peak picking and stochastic subspace identification, and are compared with the finite element model results and verified the reliability of recognition results. The identified dynamic properties can be served as the basis in the finite element model updating, damage detection, condition assessment and health monitoring of the bridge.

  16. Measurement of Mechatronic Property of Biological Gel with Micro-Vibrating Electrode at Ultrasonic Frequency

    Directory of Open Access Journals (Sweden)

    Shigehiro Hashimoto

    2008-10-01

    Full Text Available A measurement system has been designed with a micro-vibrating electrode at ultrasonic frequency to measure local impedance of biological gel in vitro. The designed system consists of two electrodes, where one of the electrodes vibrates with a piezoelectric actuator. The component of variation at impedance between two electrodes with vibration of one electrode is analyzed at the corresponding spectrum. The manufactured system was applied to measure impedance of a physiological saline solution, a potassium chloride solution, a dextran aqueous solution, and an egg. The experimental results show that the designed system is effective to measure local mechatronic property of biological gel.

  17. Monitoring and evaluating civil structures using measured vibration

    Science.gov (United States)

    Straser, Erik G.; Kiremidjian, Anne S.

    1996-04-01

    The need for a rapid assessment of the state of critical and conventional civil structures, such as bridges, control centers, airports, and hospitals, among many, has been amply demonstrated during recent natural disasters. Research is underway at Stanford University to develop a state-of-the-art automated damage monitoring system for long term and extreme event monitoring based on both ambient and forced response measurements. Such research requires a multi-disciplinary approach harnessing the talents and expertise of civil, electrical, and mechanical engineering to arrive at a novel hardware and software solution. Recent advances in silicon micro-machining and microprocessor design allow for the economical integration of sensing, processing, and communication components. Coupling these technological advances with parameter identification algorithms allows for the realization of extreme event damage monitoring systems for civil structures. This paper addresses the first steps toward the development of a near real-time damage diagnostic and monitoring system based on structural response to extreme events. Specifically, micro-electro-mechanical- structures (MEMS) and microcontroller embedded systems (MES) are demonstrated to be an effective platform for the measurement and analysis of civil structures. Experimental laboratory tests with small scale model specimens and a preliminary sensor module are used to evaluate hardware and obtain structural response data from input accelerograms. A multi-step analysis procedure employing ordinary least squares (OLS), extended Kalman filtering (EKF), and a substructuring approach is conducted to extract system characteristics of the model. Results from experimental tests and system identification (SI) procedures as well as fundamental system design issues are presented.

  18. Ambient dose measurement and personal dosimetry in nuclear medicine

    International Nuclear Information System (INIS)

    The dose measurements reported were performed with TLD dosemeters consisting of two glass tubes filled with CaSO4:TM powder. The measurements were done around a positron emission tomograph, in a nuclear medicine outpatient department, and in a hospital (therapy with unsealed radioactive substances). The personal doses measured during the campaign reported did not exceed the range of radiation doses and its fluctuations due to natural radiation exposure of the population. (DG)

  19. Health monitoring of aeronautical structures based on vibrations measurements

    Science.gov (United States)

    Bovio, Igor; Lecce, Leonardo

    2006-03-01

    Purpose of the paper is to present an innovative application inside the Non Destructive Testing field based on vibrations measurements, developed by the authors during the last three years, and already tested for analysing damage of many structural elements. The proposed new method is based on the acquisition and comparison of Frequency Response Functions (FRFs) of the monitored structure before and after an occurred damage. Structural damage modify the dynamical behaviour of the structure such as mass, stiffened and damping, and consequently the FRFs of the damaged structure in comparison with the FRFs of the sound structure, making possible to identify, to localize and quantify a structural damage. The activities, presented in the paper, mostly focused on a new FRFs processing technique based on the determining of a representative "Damage Index" for identifying and analysing damage both on real scale aeronautical structural components, like large-scale fuselage reinforced panels, and on aeronautical composite panels. Besides it has been carried out a dedicated neural network algorithm aiming at obtaining a "recognition-based learning"; this kind of learning methodology permits to train the neural network in order to let it recognises only "positive" examples discarding as a consequence the "negative" ones. Within the structural NDT a "positive" example means "healthy" state of the analysed structural component and, obviously, a "negative" one means a "damaged" or perturbed state. From an architectural point of view piezoceramic patches have been tested as actuators and sensors. Besides it has been used a laser-scanning vibrometer system to validate the behaviour of the piezoceramic patches.

  20. Discrete time interval measurement system: fundamentals, resolution and errors in the measurement of angular vibrations

    International Nuclear Information System (INIS)

    The traditional method for measuring the velocity and the angular vibration in the shaft of rotating machines using incremental encoders is based on counting the pulses at given time intervals. This method is generically called the time interval measurement system (TIMS). A variant of this method that we have developed in this work consists of measuring the corresponding time of each pulse from the encoder and sampling the signal by means of an A/D converter as if it were an analog signal, that is to say, in discrete time. For this reason, we have denominated this method as the discrete time interval measurement system (DTIMS). This measurement system provides a substantial improvement in the precision and frequency resolution compared with the traditional method of counting pulses. In addition, this method permits modification of the width of some pulses in order to obtain a mark-phase on every lap. This paper explains the theoretical fundamentals of the DTIMS and its application for measuring the angular vibrations of rotating machines. It also displays the required relationship between the sampling rate of the signal, the number of pulses of the encoder and the rotating velocity in order to obtain the required resolution and to delimit the methodological errors in the measurement

  1. Crack propagation analysis of rotating shafts by vibration measurement

    International Nuclear Information System (INIS)

    The valuation of rotor crack damage is done by shaft vibration monitoring followed by an interpretatioin of the results, which are frequently supported by calculations. The connection between crack depth, contour and shape of the crack surfaces of propagating transverse crack and the vibration response of a slender uniform shaft made of a material, which is tough to fracture, is experimentally found and is illustrated with the help of examples. Beach marks are set in the structural surface to mark the correct contour of the cracked cross section at selected points of time. Suggestions are made how cracked rotors can be modelled. (orig.)

  2. Vibration isolation measures due to the high sensitive linear accelerator at the Paul Scherrer Institute

    Directory of Open Access Journals (Sweden)

    Trombik Peter

    2015-01-01

    Full Text Available The new 735m long linear accelerator “SwissFEL” at the Paul Scherrer Institute (PSI in Würenlingen is extremely sensitive against vibrations coming from surrounding equipment (pumps, ventilators, transformers, etc.. The manufacturer’s vibration limit for this linear accelerator is 0.1μm displacement amplitude. Therefore, all vibration sources must strictly be isolated to the highest-possible degree from the rest of the structure. This paper discusses the vibration situation in general for this unique construction (ground vibrations, vibration propagations / structural amplifications, vibration limits, etc. and as a case study the isolation of a pump located in the building. Steel springs were used and it was achieved to reduce the vibration transmitted to the floor by more than 99%, to a level where the coherent component of the motion recorded on the floor next to the linear accelerator is non-measurable / below the ground motions. The measurements were found to be in good accordance with the FEM model used.

  3. Ambient aromatic hydrocarbon measurements at Welgegund, South Africa

    Energy Technology Data Exchange (ETDEWEB)

    Jaars, K.; Beukes, J. P.; van Zyl, P. G.; Venter, A. D.; Josipovic, M.; Pienaar, J. J.; Vakkari, Ville; Aaltonen, H.; Laakso, H.; Kulmala, M.; Tiitta, P.; Guenther, Alex B.; Hellen, H.; Laakso, L.; Hakola, H.

    2014-07-11

    Aromatic hydrocarbons are associated with direct adverse human health effects and can have negative impacts on ecosystems due to their toxicity, as well as indirect negative effects through the formation of tropospheric ozone and secondary organic aerosol that affect human health, crop production and regional climate. Measurements were conducted at the Welgegund measurement station (South Africa) that is considered to be a regionally representative background site. However, the site is occasionally impacted by plumes from major anthropogenic source regions in the interior of South Africa, which include the western Bushveld Igneous Complex (e.g. platinum, base metal and ferrochrome smelters), the eastern Bushveld Igneous Complex (platinum and ferrochrome smelters), the Johannesburg-Pretoria metropolitan conurbation (>10 million people), the Vaal Triangle (e.g. petrochemical and industries), the Mpumalanga Highveld (e.g. coal-fired power plants and petrochemical industry) and also a region of anti-cyclonic recirculation of air mass over the interior of South Africa. The aromatic hydrocarbon measurements were conducted with an automated sampler on Tenax-TA and Carbopack-B adsorbent tubes with heated inlet for one year. Samples were collected twice a week for two hours during daytime and two hours 1 during night-time. A thermal desorption unit, connected to a gas chromatograph and a mass 2 selective detector was used for sample preparation and analysis. Results indicated that the 3 monthly median total aromatic hydrocarbon concentrations ranged between 0.01 to 3.1 ppb. 4 Benzene levels did not exceed local air quality standards. Toluene was the most abundant 5 species, with an annual median concentration of 0.63 ppb. No statistically significant 6 differences in the concentrations measured during daytime and night-time were found and no distinct seasonal patterns were observed. Air mass back trajectory analysis proved that the lack of seasonal cycles could be

  4. Ambient aromatic hydrocarbon measurements at Welgegund, South Africa

    Directory of Open Access Journals (Sweden)

    K. Jaars

    2014-02-01

    Full Text Available Aromatic hydrocarbons are associated with direct adverse human health effects and can have negative impacts on ecosystems due to their toxicity, as well as indirect negative effects through the formation of tropospheric ozone and secondary organic aerosol that affect human health, crop production and regional climate. Measurements were conducted at the Welgegund measurement station (South Africa that is considered to be a regionally representative background site. However, the site is occasionally impacted by plumes from major anthropogenic source regions in the interior of South Africa, which include the western Bushveld Igneous Complex (e.g. platinum, base metal and ferrochrome smelters, the eastern Bushveld Igneous Complex (platinum and ferrochrome smelters, the Johannesburg–Pretoria metropolitan conurbation (>10 million people, the Vaal Triangle (e.g. petrochemical and pyrometallurgical industries, the Mpumalanga Highveld (e.g. coal-fired power plants and petrochemical industry and also a region of anti-cyclonic recirculation of air mass over the interior of South Africa. The aromatic hydrocarbon measurements were conducted with an automated sampler on Tenax-TA and Carbopack-B adsorbent tubes with heated inlet for one year. Samples were collected twice a week for two hours during daytime and two hours during night-time. A thermal desorption unit, connected to a gas chromatograph and a mass selective detector was used for sample preparation and analysis. Results indicated that the monthly median total aromatic hydrocarbon concentrations ranged between 0.01 to 3.1 ppb. Benzene levels did not exceed local air quality standards. Toluene was the most abundant species, with an annual median concentration of 0.63 ppb. No statistically significant differences in the concentrations measured during daytime and night-time were found and no distinct seasonal patterns were observed. Air mass back trajectory analysis proved that the lack of seasonal

  5. Transverse vibrations of electron beam and ground motion measurements at VEPP-3 storage ring

    International Nuclear Information System (INIS)

    This paper is devoted to measurements of electron beam vibration at VEPP-3 storage ring. We measured simultaneously the beam vertical position by synchrotron radiation monitor, floor and magnetic quadrupole lens vibrations. The analysis of spectra of power and correlations points on strong connection of mechanical vibrations of lenses and beam movement at frequencies below 40 Hz and on definite influence of current supply fluctuations in the frequency range above hundred Hz. These results could be applied for design of various accelerator facilities such as SR sources, B-factories and large future colliders. 4 refs.; 8 figs

  6. Vibration characteristics of composite fan blades and comparison with measured data

    Science.gov (United States)

    Chamis, C. C.

    1976-01-01

    The vibration characteristics of a composite fan blade for high-tip-speed applications were determined theoretically and the results compared with measured data. The theoretical results were obtained using a computerized capability consisting of NASTRAN coupled with composite mechanics by way of pre- and postprocessors. The predicted vibration frequencies and mode shapes were in reasonable agreement with the measured data. Theoretical results showed that different laminate configurations from the same composite system had only small effects on the blade frequency. However, the use of adhesively bonded titanium/beryllium laminar composites may improve considerably the blade vibration characteristics.

  7. Simultaneous Static Strain, Temperature and Vibration Measurement Using an Integrated FBG/EFPI Sensor

    Institute of Scientific and Technical Information of China (English)

    曾祥楷; 饶云江

    2001-01-01

    A novel technique for simultaneous measurement of static strain, temperature and vibration in health monitoring of structures is demonstrated using an integrated in-fibre Bragg grating (FBG)/extrinsic Fabry-Pérot interferometer (EFPI) sensor. The EFPI sensor provides static strain and vibration information simultaneously by using the channel-spectrum method and the low-coherence interferometric technique, respectively. The FBG sensor is used for temperature measurement. The experimental results show that a static-strain accuracy of l20με, a temperature accuracy of +l℃ and a vibration resolution of 1 nm have been achieved with a good repeatability.

  8. Blade Vibration Measurement System for Characterization of Closely Spaced Modes and Mistuning Project

    Data.gov (United States)

    National Aeronautics and Space Administration — There are several ongoing challenges in non-contacting blade vibration and stress measurement systems that can address closely spaced modes and blade-to-blade...

  9. Vibration measurements and analysis for the reactor vessel and internals of the SNR-300

    International Nuclear Information System (INIS)

    During normal operation the SNR-300 LMFBR power plant has a well defined coolant flow distribution with a moderate velocity level. The flow induced vibration potential is therefore very low. Nevertheless much effort has been devoted to study the vibrational behaviour of the reactor internals and the vessel structure. In recent years a number of flow vibration tests in water loops and performance tests in sodium have been conducted with SNR fuel assemblies. Although some uncertainty will remain due to the reactor environment, the experimental evidence from these tests indicates that flow induced vibration in SNR-300 fuel assemblies will be insignificant. In order to meet the licensing conditions for securing the integrity of the internals, an iterative procedure is planned, consisting of theoretical and experimental structure analysis and a final vibration measurement during reactor commissioning. First results are presented. (author)

  10. Methods for calibration of the vibration measurement system EVME used on the JAS 39 Gripen engine.

    OpenAIRE

    Backlund, Ludvig; Martin, Anna; Svantesson, Gustaf

    2014-01-01

    This project investigates methods for calibrating and functional testing an Engine Vibration Measurement Equipment. The equipment uses accelerometers to measure vibrations on the JAS 39 Gripen aircraft engine to ensure that the engine is correctly installed. A model for emulating the electronic signals generated by the accelerometers was created in Simulink and different ways for utilizing the model as a part of a complete test system were examined. Upon examination of different calibration m...

  11. Development of method to measure vibrational stress with multiple displacement sensors. Examination of applicability by vibration test using mock-up piping

    International Nuclear Information System (INIS)

    In the nuclear power plants, many small-bore piping are frequently oscillated by vibrational sources like pumps, and it is important to evaluate vibration stress of the piping efficiently to prevent the fatigue failure. This study proposes a new method developed to calculate vibration stress using displacements measured by multiple contactless displacement sensors. In this study, the applicability of the proposed method was verified with vibration experiments by using an actual mock-up piping. The experiments were conducted under sweep operations or steady operations of rotation frequency of pump. The stress calculated by the proposed method was compared with the stress measured by strain gauge. As the results, the calculated stress was in good agreement with the measured stress though having some error which was negligible comparing to endurance limit of failure. Therefore, the method developed was applicable to measure vibration stress of small-bore piping in the actual plants. (author)

  12. Application of range imaging lidar for measurement of mechanical vibration and frequency mode distribution

    Science.gov (United States)

    Zhang, Hua A.; Zhu, Yonghao; He, Yun

    1993-05-01

    This article reports the application of laser range imaging radar in the measurement of mechanical vibration frequency and the mode distribution, and the periodic motion of the mechanical parts such as a piston rod. The principle of the laser range imaging radar is based on the phase shift of the reflected amplitude modulated laser beam. The mechanical vibration frequency up to 20 KHZ and the minimal retrieved amplitude (or the motion displacement) of 0.5 mm have been achieved with the laser modulating frequency of 40 MHZ. With appropriate modulating frequency, this laser range system can measure the mechanical vibration amplitude, or the moving displacement, from 10-1 mm up to 102 mm, or even higher to the order of meters, which will be useful to measure the vibration and the periodic motion of machines and their parts for field test.

  13. Vibration-Induced Conductivity Fluctuation Measurement for Soil Bulk Density Analysis

    CERN Document Server

    Kishne, Andrea Sz; Chang, Hung-Chih; Kish, Laszlo B

    2007-01-01

    Soil bulk density affects water storage, water and nutrient movement, and plant root activity in the soil profile. Its measurement is difficult in field conditions. Vibration-induced conductivity fluctuation was investigated to quantify soil bulk density with possible field applications in the future. The AC electrical conductivity of soil was measured using a pair of blade-like electrodes while exposing the soil to periodic vibration. The blades were positioned longitudinally and transversally to the direction of the induced vibration to enable the calculation of a normalized index. The normalized index was expected to provide data independent from the vibration strength and to reduce the effect of soil salinity and water content. The experiment was conducted on natural and salinized fine sand at two moisture conditions and four bulk densities. The blade-shaped electrodes improved electrode-soil contact compared to cylindrical electrodes, and thereby, reduced measurement noise. Simulations on a simplified re...

  14. Semiconductor laser self-mixing micro-vibration measuring technology based on Hilbert transform

    Science.gov (United States)

    Tao, Yufeng; Wang, Ming; Xia, Wei

    2016-06-01

    A signal-processing synthesizing Wavelet transform and Hilbert transform is employed to measurement of uniform or non-uniform vibrations in self-mixing interferometer on semiconductor laser diode with quantum well. Background noise and fringe inclination are solved by decomposing effect, fringe counting is adopted to automatic determine decomposing level, a couple of exact quadrature signals are produced by Hilbert transform to extract vibration. The tempting potential of real-time measuring micro vibration with high accuracy and wide dynamic response bandwidth using proposed method is proven by both simulation and experiment. Advantages and error sources are presented as well. Main features of proposed semiconductor laser self-mixing interferometer are constant current supply, high resolution, simplest optical path and much higher tolerance to feedback level than existing self-mixing interferometers, which is competitive for non-contact vibration measurement.

  15. Vibration isolation for seismocardiogram measurement in the openMRI-guided operating theater

    International Nuclear Information System (INIS)

    The purpose of this study is to establish a method of measuring precisely the seismocardiogram (SCG) of a patient who lying in an open magnetic resonance imaging (openMRI) machine for myocardial ischemia monitoring during surgery. Vibration isolation was examined by analyzing the gantry vibration during MRI scanning and the SCG of a healthy volunteer. The MRI gantry vibration had maximum amplitude of 2.5 m/s2, which are several peaks more than 100 Hz up to 500 Hz. Up to 94% reduction in amplitude was observed in the patient bed vibration under both T1-weighted and T2-weighted sequences. The power spectrum center of the patient bed vibration was more than 30 Hz. The maximum amplitude of SCG was 0.92 m/s2 and a FET analysis revealed that the SCG was not higher than 25 Hz. The signal-to-noise ratio between the SCG and the patient bed vibration was calculated to be from 4 to 7. These results demonstrate that the peak acceleration of the SCG can be monitored during open MRI scanning. In conclusion, vibration analysis showed the feasibility of using the piezoelectric acceleration sensor for seismocardiogram measurement in the open MRI-guided operating theater. (author)

  16. A New Approach for Reliability Life Prediction of Rail Vehicle Axle by Considering Vibration Measurement

    Directory of Open Access Journals (Sweden)

    Meral Bayraktar

    2014-01-01

    Full Text Available The effect of vibration on the axle has been considered. Vibration measurements at different speeds have been performed on the axle of a running rail vehicle to figure out displacement, acceleration, time, and frequency response. Based on the experimental works, equivalent stress has been used to find out life of the axles for 90% and 10% reliability. Calculated life values of the rail vehicle axle have been compared with the real life data and it is found that the life of a vehicle axle taking into account the vibration effects is in good agreement with the real life of the axle.

  17. Effects of Cation Disordering in Magnesium Aluminate Spinel on the Rectangular Parallelepiped Resonance and Raman Measurements of Vibrational Spectra

    Science.gov (United States)

    Cynn, Hyunchae

    The effects of cation disordering of a natural MgAl_2O_4^inel on acoustic and optic vibration were measured for the first time using the rectangular parallelepiped resonance method and Raman measurements. In the resonant frequency measurements of a natural spinel at high temperatures over the temperature range 298 to 1068 K, a discontinuous increase in the measured acoustic resonant vibrations of the lower harmonic modes and a discontinuous decrease in the measured acoustic resonant vibrations of the higher harmonic modes were observed at around 1000 K. Similar differences among the resonant frequencies were also observed at ambient conditions between a less disordered spinel and the highly disordered states of a natural spinel. In the Raman measurements of the same natural spinel over the temperature range 298 to 1424 K, plots of the Raman vibrational frequencies of the external and internal vibrational modes versus temperature change slopes at around 1000 K. These two measurements clearly indicate that a major change occurred at 1000 K, which I label as a transition temperature. I interpret the change that occurred around 1000 K as the onset of cation disordering in the natural spinel. The interpretation is consistent with the following observations: (1) an abrupt decrease in oxygen positional parameter in an x-ray single crystal structure analysis of a synthetic spinel between 873 and 973 K; (2) a discontinuous decrease of linear thermal expansion coefficients in a synthetic spinel at 933 K by dilatometry, and (3) a discontinuous decrease of the unit cell parameter of a natural spinel at around 1073 K by x-ray diffraction. The adiabatic elastic moduli found here for the natural spinel are different from results which have been previously reported by others, however, the moduli of a disordered natural spinel are similar to those previously reported for synthetic spinels. These observations demonstrate that cation disordering of a spinel clearly affects the

  18. Interactive effects of ambient ozone and climate measured on growth of mature loblolly pine trees

    Energy Technology Data Exchange (ETDEWEB)

    McLaughlin, S.B. [Oak Ridge National Lab., TN (United States). Environmental Sciences Div.; Downing, D.J. [Oak Ridge National Lab., TN (United States). Engineering Physics and Mathematics Div.

    1996-04-01

    The effects of ambient ozone on the growth of large trees were evaluated. A 6-year study was conducted at a site in eastern Tennessee where seasonal growth patterns of mature loblolly pine trees were analysed. Patterns of stem expansion and contraction of 34 trees were studied using serial measurements with dendrometer band systems. Soil moisture, soil fertility and stand density were varied. Levels of ozone, rainfall and temperature also varied. Results showed that ozone interacted with both soil moisture stress and high temperatures. It was concluded that relatively low levels of ambient ozone can significantly reduce growth of mature forest tress and interactions between ambient ozone and climate were important modifiers of future forest growth and function. 49 refs., 6 tabs., 4 figs.

  19. Double resonant absorption measurement of acetylene symmetric vibrational states probed with cavity ring down spectroscopy

    CERN Document Server

    Karhu, J; Vainio, M; Metsälä, M; Hoekstra, S; Halonen, L

    2016-01-01

    A novel mid-infrared/near-infrared double resonant absorption setup for studying infrared-inactive vibrational states is presented. A strong vibrational transition in the mid-infrared region is excited using an idler beam from a singly resonant continuous-wave optical parametric oscillator, to populate an intermediate vibrational state. High output power of the optical parametric oscillator and the strength of the mid-infrared transition result in efficient population transfer to the intermediate state, which allows measuring secondary transitions from this state with a high signal-to-noise ratio. A secondary, near-infrared transition from the intermediate state is probed using cavity ring down spectroscopy, which provides high sensitivity in this wavelength region. Due to the narrow linewidths of the excitation sources, the rovibrational lines of the secondary transition are measured with sub-Doppler resolution. The setup is used to access a previously unreported symmetric vibrational state of acetylene, $\

  20. Measurement and suppression of cutting tool vibration using piezoelectric ceramic in ansys

    International Nuclear Information System (INIS)

    To measure vibration produced in lathe cutting tool various kinds of procedures are adopted. Small patch of piezoelectric ceramic material is successfully incorporated into turning cutting which is modeled in Pro Engineer and examined in finite element analysis to check vibrations in material cutting processes. Model and harmonic analysis are performed. The relative amplitudes of mode shapes and frequencies are identified by analyses which are causing chatter. The results are compared with the analysis which is performed without using piezoelectric material patch. (author)

  1. Application of blasting vibration measurement to underground deep-hole blasting of a uranium deposit

    International Nuclear Information System (INIS)

    Aimed at the potential vibration damage to residents' houses on surface after underground deep-hole blasting of a uranium deposit in stope leaching, two real-time blasting vibration measurements were made. The safe distance and safety criterion of maximum charge weight on millisecond delay explosive in large-scale blasting of the uranium deposit were summed up. These data can provide the design basis for future large scale ore stacking by blasting. (authors)

  2. Identification of Critical Speeds of Rotating Machines Using On-Shaft Wireless Vibration Measurement

    International Nuclear Information System (INIS)

    On-shaft vibration (OSV) together with the wireless router has been used for the vibration based condition monitoring (VCM) and the method has been applied to a small experimental rig. The observations made on the measured OSV data during the rig run-up operation, in particular the identification of the rig critical speeds from the OSV run-up data are presented in this paper.

  3. Features of measurement and processing of vibration signals registered on the moving parts of electrical machines

    OpenAIRE

    Gyzhko, Yuri

    2011-01-01

    Measurement and processing of vibration signals registered on the moving parts of the electrical machines using the diagnostic information-measuring system that uses Bluetooth wireless standard for the transmission of the measured data from moving parts of electrical machine is discussed.

  4. Photon burst mass spectrometry for the measurement of Krypton-85 at ambient levels

    International Nuclear Information System (INIS)

    Photon Burst Mass Spectrometry has been used to measure 85Kr in a sample with an abundance of 6 x 10-9. Improvements in detection efficiency by the use of avalanche photodiodes cooled to liquid nitrogen temperature are reported, which should make possible measurement of 85Kr at the ambient atmospheric abundance of 10-11. Potential applications include nuclear monitoring, atmospheric transport, and dating young ground water up to 40 years

  5. Atomic oxygen in a cold argon plasma jet: TALIF spectroscopy in ambient air with modelling and measurements of ambient species diffusion

    International Nuclear Information System (INIS)

    By investigating the atomic oxygen density in its effluent, two-photon absorption laser-induced fluorescence (TALIF) spectroscopy measurements are for the first time performed in a cold argon/oxygen atmospheric pressure plasma jet. The measurements are carried out in ambient air and quenching by inflowing air species is considered. We propose a novel absorption technique in the VUV spectral range, where emission originating from within the discharge is used as light source to determine the inflow of atmospheric oxygen into the effluent. Furthermore, we propose a modelling solution for the on-axis density of inflowing ambient air based on the stationary convection–diffusion equation. (paper)

  6. Measurement of Vibrational Non-Equilibrium in a Supersonic Freestream Using Dual-Pump CARS

    Science.gov (United States)

    Cutler, Andrew D.; Magnotti, Gaetano; Cantu, Luca M. L.; Gallo, Emanuela C. A.; Danehy, Paul M.; Burle, Rob; Rockwell, Robert; Goyne, Christopher; McDaniel, James

    2012-01-01

    Measurements have been conducted at the University of Virginia Supersonic Combustion Facility of the flow in a constant area duct downstream of a Mach 2 nozzle, where the airflow has first been heated to approximately 1200 K. Dual-pump CARS was used to acquire rotational and vibrational temperatures of N2 and O2 at two planes in the duct at different downstream distances from the nozzle exit. Wall static pressures in the nozzle are also reported. With a flow of clean air, the vibrational temperature of N2 freezes at close to the heater stagnation temperature, while the O2 vibrational temperature is about 1000 K. The results are well predicted by computational fluid mechanics models employing separate "lumped" vibrational and translational/rotational temperatures. Experimental results are also reported for a few percent steam addition to the air and the effect of the steam is to bring the flow to thermal equilibrium.

  7. Vibration measurement based on electronic speckle pattern interferometry and radial basis function

    Science.gov (United States)

    Dai, Xiangjun; Shao, Xinxing; Geng, Zhencen; Yang, Fujun; Jiang, Yijun; He, Xiaoyuan

    2015-11-01

    A method incorporating amplitude-fluctuation electronic speckle pattern interferometry (AF-ESPI) with radial basis function (RBF) was proposed to investigate vibration characteristics of structures. The vibration patterns were obtained by AF-ESPI. A novel pre-filtering RBF method was presented to improve the quality of patterns. The out-of-plane vibration amplitude was rebuilt after fringe analysis. Ideal pre-filtering widow sizes for the presented RBF were given based on numerical experiments. For validation, an aluminum circular plate with fixed boundary was determined and compared with FEM, confirming the effectiveness of the proposed method. Finally, vibration characteristics of sandwich panels with honeycomb core were measured. The influence of presence of a pre-notch at different location was also investigated.

  8. Intercomparison of tunable diode laser and gas filter correlation measurements of ambient carbon monoxide

    Science.gov (United States)

    Fried, Alan; Henry, Bruce; Parrish, David D.; Carpenter, James R.; Buhr, Martin P.

    An intercomparison that involved a standards intercomparison, interferant spiking tests and simultaneous ambient measurements was carried out between two CO measurement systems: a tunable diode laser absorption spectrometer (TDLAS) and a gas filter correlation, non-dispersive infrared absorption instrument (GFC). Both the TDLAS and the GFC techniques responded to CO. No major interferences were found for the TDLAS system; tested species included H 2O, O 3 and OCS. The GFC instrument exhibited no interference from H 2O or O 3, but only a relatively high upper limit could be placed on the O 3 interference. For CO measurements in ambient air at levels from 100 to 1500 ppbv, the results from the two instruments agreed within their combined uncertainties. On average the GFC technique was 6% higher than the TDLAS system, and there was no systematic, constant offset. The precision of the GFC instrument was about 10%, and the precision of the TDLAS system was better than 4%.

  9. Measurement of unsteady flow forces in inline and staggered tube bundles with fixed and vibrating tubes

    International Nuclear Information System (INIS)

    Unsteady flow forces arising in heat exchangers with cross-flow may lead to serious vibrations of the tubes. These vibrations can destroy the tubes in the end supports or in the baffles, which would require expensive repairs. The flow forces reach unexpectedly by high values if the vibration of the tube intensifies these forces. To clear up this coupling mechanism the flow forces and the vibration amplitude were measured simultaneously in a staggered and in an inline tube bundle. Considering the tube as a one-mass oscillator excited by the flow force, the main parameters can be derived, i.e. dynamic pressure, reduced mass, eigenfrequency and damping. These parameters form a dimensionless model number describing the coherence of the vibration amplitude and the force coefficient. The validity of this number has been confirmed by varying the test conditions. With the aid of this model number, the expected force coefficient can be calculated and then using a finite-element program information can be obtained about mechanical tensions and the lifetime of the heat exchanger tubes. With this model number the results of other authors, who measured the vibration amplitude only, could be confirmed in good agreement. The experiments were carried out in air with Reynolds numbers 1045. (orig.)

  10. Sum frequency generation vibrational spectroscopy at solid gas interfaces: CO adsorption on Pd model catalysts at ambient pressure

    Science.gov (United States)

    Rupprechter, Günther; Unterhalt, Holger; Morkel, Matthias; Galletto, Paolo; Hu, Linjie; Freund, Hans-Joachim

    2002-04-01

    Carbon monoxide adsorption on Pd(1 1 1) and Pd nanoparticles supported by Al 2O 3/NiAl(1 1 0) was examined by vibrational sum frequency generation spectroscopy from 10 -8 to 1000 mbar, and from 100 to 400 K. Identical CO saturation structures were observed on Pd(1 1 1) under ultrahigh vacuum (˜10 -7 mbar, 95 K) and at high pressure (e.g. ⩾1 mbar, 190 K) with no indications of pressure-induced surface rearrangements. Special attention was paid to experimental artifacts that may occur under elevated pressure and may be misinterpreted as "high pressure effects". Vibrational spectra of CO on defect-rich Pd(1 1 1) exhibited an additional peak that originated from CO bound to defect (step or edge) sites. The CO adsorbate structure on supported Pd nanoparticles was different from Pd(1 1 1) but more similar to stepped Pd(1 1 1). At low pressure (10 -7 mbar CO) the adsorbate structure depended strongly on the Pd morphology revealing specific differences in the adsorption properties of supported nanoparticles and single crystal surfaces. At high pressure (e.g. 200 mbar CO) these differences were even more pronounced. Prominent high coverage CO structures on Pd(1 1 1) could not be established on Pd particles. However, in spite of structural differences between well faceted and rough Pd nanoparticles nearly identical adsorption site occupancies were observed in both cases at 200 mbar CO. Initial tests of the catalytic activity of Pd/Al 2O 3/NiAl(1 1 0) for ethylene hydrogenation at 1 bar revealed a remarkable activity and stability of the model system with catalytic properties similar to impregnated catalysts.

  11. Characteristics of Ambient Volatile Organic Compounds (VOCs Measured in Shanghai, China

    Directory of Open Access Journals (Sweden)

    Guang-Qiang Zhou

    2010-08-01

    Full Text Available To better understand the characteristics of ambient abundance of volatile organic compounds (VOCs in Shanghai, one of the biggest metropolis of China, VOCs were measured with a gas chromatography system equipped with a mass-selective detector (GC/MSD from July 2006 to February 2010. An intensive measurement campaign was conducted (eight samples per day with a 3 hour interval during May 2009. The comparison of ambient VOCs collected in different regions of Shanghai shows that the concentrations are slightly higher in the busy commercial area (28.9 ppbv at Xujiaui than in the urban administrative area (24.3 ppbv at Pudong. However, during the intensive measurement period, the concentrations in the large steel industrial area (28.7 ppbv at Baoshan were much higher than in the urban administrative area (18 ppbv at Pudong, especially for alkanes, alkenes, and toluene. The seasonal variations of ambient VOC concentrations measured at the Xujiahui sampling site indicate that the VOC concentrations are significantly affected by meteorological conditions (such as wind direction and precipitation. In addition, although alkanes are the most abundant VOCs at the Xujiahui measurement site, the most important VOCs contributing to ozone formation potential (OFP are aromatics, accounting for 57% of the total OFP. The diurnal variations of VOC concentrations show that VOC concentrations are higher on weekdays than in weekends at the Xujiahui sampling site, suggesting that traffic condition and human activities have important impacts on VOC emissions in Shanghai. The evidence also shows that the major sources of isoprene are mainly resulted from gasoline evaporation at a particular time (06:00–09:00 in the busy commercial area. The results gained from this study provide useful information for better understanding the characteristics of ambient VOCs and the sources of VOCs in Shanghai.

  12. Combined Amplitude and Frequency Measurements for Non-Contacting Turbomachinery Blade Vibration

    Science.gov (United States)

    Platt, Michael J. (Inventor); Jagodnik, John J. (Inventor)

    2013-01-01

    A method and apparatus for measuring the vibration of rotating blades, such as turbines, compressors, fans, or pumps, including sensing the return signal from projected energy and/or field changes from a plurality of sensors mounted on the machine housing. One or more of the sensors has a narrow field of measurement and the data is processed to provide the referenced time of arrival of each blade, and therefore the blade tip deflection due to vibration. One or more of the sensors has a wide field of measurement, providing a time history of the approaching and receding blades, and the data is processed to provide frequency content and relative magnitudes of the active mode(s) of blade vibration. By combining the overall tip deflection magnitude with the relative magnitudes of the active modes, the total vibratory stress state of the blade can be determined.

  13. Quantitative estimation of the influence of external vibrations on the measurement error of a coriolis mass-flow meter

    OpenAIRE

    Ridder, de, J.; Hakvoort, W.B.J.; van Dijk; Lötters, J.C.; Boer, de, J.W.; Dimitrovova, Z.; Almeida, De

    2013-01-01

    In this paper the quantitative influence of external vibrations on the measurement value of a Coriolis Mass-Flow Meter for low flows is investigated, with the eventual goal to reduce the influence of vibrations. Model results are compared with experimental results to improve the knowledge on how external vibrations affect the measurement error. A Coriolis Mass-Flow Meter (CMFM) is an active device based on the Coriolis force principle for direct mass-flow measurements, independent of fluid pr...

  14. On measuring surface wave phase velocity from station-station cross-correlation of ambient signal

    OpenAIRE

    Boschi, Lapo; Weemstra, Cornelis; Verbeke, Julie; Ekström, Göran; Zunino, Andrea; Giardini, Domenico

    2013-01-01

    International audience We apply two different algorithms to measure surface wave phase velocity, as a function of frequency, from seismic ambient noise recorded at pairs of stations from a large European network. The two methods are based on consistent theoretical formulations, but differ in the implementation: one method involves the time-domain cross-correlation of signal recorded at different stations; the other is based on frequency-domain cross-correlation, and requires finding the ze...

  15. On-site vibration fault diagnosis and solution measures of a centrifugal charging pump in nuclear power plant

    International Nuclear Information System (INIS)

    Vibration measurement of equipment during commissioning of nuclear power plants is one of important measures to ensure the plant safety. In this paper, through vibration measurement of the centrifugal charging pump during commission of a certain nuclear power plant, vibration fault of the pump is found. According to the signal features measured, faults of mass unbalance and uneven torque for the foundation bolts are diagnosed, and corresponding measures are implemented, which finally solve the vibration problem of this pump. The diagnosis process of the pump demonstrates that vibration faults of on-site equipment often have several causes, and even the same symptoms have different reasons. The vibration problem of the centrifugal charging pump in this paper is meaningful for solving practical engineering problems, and will provide important instructions and reference for disposing similar problems. (authors)

  16. Model-based failure detection for cylindrical shells from noisy vibration measurements.

    Science.gov (United States)

    Candy, J V; Fisher, K A; Guidry, B L; Chambers, D H

    2014-12-01

    Model-based processing is a theoretically sound methodology to address difficult objectives in complex physical problems involving multi-channel sensor measurement systems. It involves the incorporation of analytical models of both physical phenomenology (complex vibrating structures, noisy operating environment, etc.) and the measurement processes (sensor networks and including noise) into the processor to extract the desired information. In this paper, a model-based methodology is developed to accomplish the task of online failure monitoring of a vibrating cylindrical shell externally excited by controlled excitations. A model-based processor is formulated to monitor system performance and detect potential failure conditions. The objective of this paper is to develop a real-time, model-based monitoring scheme for online diagnostics in a representative structural vibrational system based on controlled experimental data. PMID:25480059

  17. Operational military helicopter interior noise and vibration measurements with comparisons to ride quality criteria

    Science.gov (United States)

    Clevenson, S. A.; Leatherwood, J. D.; Hollenbaugh, D. D.

    1983-01-01

    Balka (1981) has identified the attainment of a 'jet-smooth' ride as a primary goal of the helicopter industry for commercial and certain military helicopters. It was noted that criteria accounting for both multiple axis vibration and interior noise are needed. The present investigation has the objective to present a vibration and interior noise data base in a format suitable for direct evaluation of aircraft ride quality. The investigation is also concerned with an assessment of the measured environment against available criteria as an indication of the state-of-the-art for current machines. Interior noise and vibration measurements were obtained on eight military helicopters during routine operational flights. The data are presented in the form of a number of parameters.

  18. Interactive effects of ambient ozone and climate measured on growth of mature loblolly pine trees

    Energy Technology Data Exchange (ETDEWEB)

    McLaughlin, S.B.; Downing, D.J.

    1995-02-01

    Analysis of the seasonal growth patterns of mature loblolly pine trees over the interval 1988-1993 has provided the first direct measurement of reductions of stem growth of large forest trees by ambient ozone. Patterns of stem expansion and contraction of 34 trees were examined in eastern Tennessee using serial measurements with sensitive dendrometer bind systems. Study sites varied in soil moisture, soil fertility, and stand density. Levels of ozone, rainfall, and temperature varied widely over the six year study interval. Regression analysis identified statistically and biologically significant influences of ozone on stem growth. Acting either individually or in interaction with high temperature and moisture stress, higher levels of ozone were associated with reduced stem expansion of individual trees within and across years. Observed responses to ozone were relatively rapid, differed widely among trees, and across years, and were significantly amplified by low soil moisture and high air temperatures. Both short term responses, clearly tied to changing stem water status, and longer term cumulative responses were identified. These data indicate that relatively low levels of ambient ozone can significantly reduce growth of mature forest trees and that interactions between ambient ozone and climate are likely to be important modifiers of future forest growth and function. Additional studies of mechanisms of short term response and inter species comparisons are clearly needed.

  19. Experimental flight test vibration measurements and nondestructive inspection on a USCG HC-130H aircraft

    Energy Technology Data Exchange (ETDEWEB)

    Moore, D.G.; Jones, C.R. [Sandia National Labs., Albuquerque, NM (United States). FAA Airworthiness Assurance NDI Validation Center; Mihelic, J.E.; Barnes, J.D. [Coast Guard Aircraft Repair and Supply Center, Elizabeth City, NC (United States)

    1998-08-01

    This paper presents results of experimental flight test vibration measurements and structural inspections performed by the Federal Aviation Administration`s Airworthiness Assurance NDI Validation Center (AANC) at Sandia National Laboratories and the US Coast Guard Aircraft Repair and Supply Center (ARSC). Structural and aerodynamic changes induced by mounting a Forward Looking Infrared (FLIR) system on a USCG HC-130H aircraft are described. The FLIR adversely affected the air flow characteristics and structural vibration on the external skin of the aircraft`s right main wheel well fairing. Upon initial discovery of skin cracking and visual observation of skin vibration in flight by the FLIR, a baseline flight without the FLIR was conducted and compared to other measurements with the FLIR installed. Nondestructive inspection procedures were developed to detect cracks in the skin and supporting structural elements and document the initial structural condition of the aircraft. Inspection results and flight test vibration data revealed that the FLIR created higher than expected flight loading and was the possible source of the skin cracking. The Coast Guard performed significant structural repair and enhancement on this aircraft, and additional in-flight vibration measurements were collected on the strengthened area both with and without the FLIR installed. After three months of further operational FLIR usage, the new aircraft skin with the enhanced structural modification was reinspected and found to be free of flaws. Additional US Coast Guard HC-130H aircraft are now being similarly modified to accommodate this FLIR system. Measurements of in-flight vibration levels with and without the FLIR installed, and both before and after the structural enhancement and repair were conducted on the skin and supporting structure in the aircraft`s right main wheel fairing. Inspection results and techniques developed to verify the aircraft`s structural integrity are discussed.

  20. Ambient Sensors

    OpenAIRE

    Börner, Dirk; Specht, Marcus

    2014-01-01

    This software sketches comprise two custom-built ambient sensors, i.e. a noise and a movement sensor. Both sensors measure an ambient value and process the values to a color gradient (green > yellow > red). The sensors were built using the Processing 1.5.1 development environment. Available under the GNU LGPL licence version 3 or higher.

  1. Ambient Sensors

    NARCIS (Netherlands)

    Börner, Dirk; Specht, Marcus

    2014-01-01

    This software sketches comprise two custom-built ambient sensors, i.e. a noise and a movement sensor. Both sensors measure an ambient value and process the values to a color gradient (green > yellow > red). The sensors were built using the Processing 1.5.1 development environment. Available under th

  2. Standardization of Laser Methods and Techniques for Vibration Measurements and Calibrations

    International Nuclear Information System (INIS)

    The realization and dissemination of the SI units of motion quantities (vibration and shock) have been based on laser interferometer methods specified in international documentary standards. New and refined laser methods and techniques developed by national metrology institutes and by leading manufacturers in the past two decades have been swiftly specified as standard methods for inclusion into in the series ISO 16063 of international documentary standards. A survey of ISO Standards for the calibration of vibration and shock transducers demonstrates the extended ranges and improved accuracy (measurement uncertainty) of laser methods and techniques for vibration and shock measurements and calibrations. The first standard for the calibration of laser vibrometers by laser interferometry or by a reference accelerometer calibrated by laser interferometry (ISO 16063-41) is on the stage of a Draft International Standard (DIS) and may be issued by the end of 2010. The standard methods with refined techniques proved to achieve wider measurement ranges and smaller measurement uncertainties than that specified in the ISO Standards. The applicability of different standardized interferometer methods to vibrations at high frequencies was recently demonstrated up to 347 kHz (acceleration amplitudes up to 350 km/s2). The relative deviations between the amplitude measurement results of the different interferometer methods that were applied simultaneously, differed by less than 1% in all cases.

  3. Quantitative measurement of tip sample forces by dynamic force spectroscopy in ambient conditions

    Science.gov (United States)

    Hölscher, H.; Anczykowski, B.

    2005-03-01

    We introduce a dynamic force spectroscopy technique enabling the quantitative measurement of conservative and dissipative tip-sample forces in ambient conditions. In difference to the commonly detected force-vs-distance curves dynamic force microscopy allows to measure the full range of tip-sample forces without hysteresis effects caused by a jump-to-contact. The approach is based on the specific behavior of a self-driven cantilever (frequency-modulation technique). Experimental applications on different samples (Fischer-sample, silicon wafer) are presented.

  4. Biogenic contribution to PM-2.5 ambient aerosol from radiocarbon measurements

    Science.gov (United States)

    Lewis, C.; Klouda, G.; Ellenson, W.

    2003-04-01

    Knowledge of the relative contributions of biogenic versus anthropogenic sources to ambient aerosol is of great interest in the formulation of strategies to achieve nationally mandated air quality standards. Radiocarbon (14C) measurements provide a means to quantify the biogenic fraction of any carbon-containing sample of ambient aerosol. In the absence of an impact from biomass burning (e.g., during summertime) such measurements can provide an estimate of the contribution of biogenic secondary organic aerosol, from biogenic volatile organic compound precursors. Radiocarbon results for 11.5-h PM-2.5 samples collected near Nashville, Tennessee, USA, during summer 1999 will be presented. On average the measured biogenic fraction was surprisingly large (more than half), with the average biogenic fraction for night samples being only slightly smaller than for day samples. Discussion will include (a) description of the radiocarbon methodology, (b) use of radiocarbon measurements on local vegetation and fuel samples as calibration data, (c) concurrent measurements of organic carbon and elemental carbon ambient concentrations, (d) assessment of organic aerosol sampling artifact through use of organic vapor denuders, variable face velocities, and filter extraction, and (e) comparison with published radiocarbon results obtained in Houston, Texas in a similar study. Disclaimer: This work has been funded wholly or in part by the United States Environmental Protection Agency under Interagency Agreement No. 13937923 to the National Institute of Standards and Technology, and Contract No. 68-D5-0049 to ManTech Environmental Tecnology, Inc. It has been subjected to Agency review and approved for publication.

  5. Observation of neutral sulfuric acid-amine containing clusters in laboratory and ambient measurements

    Directory of Open Access Journals (Sweden)

    J. Zhao

    2011-11-01

    Full Text Available Recent ab initio calculations showed that amines can enhance atmospheric sulfuric acid-water nucleation more effectively than ammonia, and this prediction has been substantiated in laboratory measurements. Laboratory studies have also shown that amines can effectively displace ammonia in several types of ammonium clusters. However, the roles of amines in cluster formation and growth at a microscopic molecular scale (from molecular sizes up to 2 nm have not yet been well understood. Processes that must be understood include the incorporation of amines into sulfuric acid clusters and the formation of organic salts in freshly nucleated particles, which contributes significantly to particle growth rates. We report the first laboratory and ambient measurements of neutral sulfuric acid-amine clusters using the Cluster CIMS, a recently-developed mass spectrometer designed for measuring neutral clusters formed in the atmosphere during nucleation. An experimental technique, which we refer to as Semi-Ambient Signal Amplification (SASA, was employed. Sulfuric acid was added to ambient air, and the concentrations and composition of clusters in this mixture were analyzed by the Cluster CIMS. This experimental approach led to significantly higher cluster concentrations than are normally found in ambient air, thereby increasing signal-to-noise levels and allowing us to study reactions between gas phase species in ambient air and sulfuric acid containing clusters. Mass peaks corresponding to clusters containing four H2SO4 molecules and one amine molecule were clearly observed, with the most abundant sulfuric acid-amine clusters being those containing a C2- or C4-amine (i.e. amines with masses of 45 and 73 amu. Evidence for C3- and C5-amines (i.e. amines with masses of 59 and 87 amu was also found, but their correlation with sulfuric acid tetramer was not as strong as was observed for the C2- and C4-amines. The formation mechanisms for

  6. The Comparative Reactivity Method ─ a new tool to measure total OH Reactivity in ambient air

    Directory of Open Access Journals (Sweden)

    J. Lelieveld

    2008-04-01

    Full Text Available Hydroxyl (OH radicals play a vital role in maintaining the oxidizing capacity of the atmosphere. To understand variations in OH radicals both source and sink terms must be understood. Currently the overall sink term, or the total atmospheric reactivity to OH, is poorly constrained. Here, we present a new on-line method to directly measure the total OH reactivity (i.e.~total loss rate of OH radicals in a sampled air mass. In this method, a reactive molecule (X, not normally present in air, is passed through a glass reactor and its concentration is monitored with a suitable detector. OH radicals are then introduced in the glass reactor at a constant rate to react with X, first in the presence of zero air and then in the presence of ambient air containing VOCs and other OH reactive species. Comparing the amount of X exiting the reactor with and without the ambient air allows the air reactivity to be determined. In our existing set up, X is pyrrole and the detector used is a proton transfer reaction mass spectrometer. The present dynamic range for ambient air reactivity is about 6 to 300 s−1, with an overall maximum uncertainty of 25% above 8 s−1 and up to 50% between 6–8 s−1. The system has been tested and calibrated with different single and mixed hydrocarbon standards showing excellent linearity and accountability with the reactivity of the standards. Potential interferences such as high NO in ambient air, varying relative humidity and photolysis of pyrrole within the setup have also been investigated. While interferences due changing humidity and photolysis of pyrrole are easily overcome by ensuring that humidity in the set up does not change drastically and the photolytic loss of pyrrole is measured and taken into account, respectively, NO>10 ppb in ambient air remains a significant interference for the current configuration of the instrument. Field tests in the tropical rainforest of Suriname (~53 s and the urban atmosphere of Mainz

  7. Measurement of Soluble and Total Hexavalent Chromium in the Ambient Airborne Particles in New Jersey

    Science.gov (United States)

    Huang, Lihui; Yu, Chang Ho; Hopke, Philip K.; Lioy, Paul J.; Buckley, Brian T.; Shin, Jin Young; Fan, Zhihua (Tina)

    2015-01-01

    Hexavalent chromium (Cr(VI)) in ambient airborne particulate matter (PM) is a known pulmonary carcinogen and may have both soluble and insoluble forms. The sum of the two forms is defined as total Cr(VI). Currently, there were no methods suitable for large-scale monitoring of total Cr(VI) in ambient PM. This study developed a method to measure total Cr(VI) in ambient PM. This method includes PM collection using a Teflon filter, microwave extraction with 3% Na2CO3-2% NaOH at 95°C for 60 minutes, and Cr(VI) analysis by 1,5-diphenylcarbazide colorimetry at 540 nm. The recoveries of total Cr(VI) were 119.5 ± 10.4% and 106.3 ± 16.7% for the Cr(VI)-certified reference materials, SQC 012 and SRM 2700, respectively. Total Cr(VI) in the reference urban PM (NIST 1648a) was 26.0 ± 3.1 mg/kg (%CV = 11.9%) determined by this method. The method detection limit was 0.33 ng/m3. This method and the one previously developed to measure ambient Cr(VI), which is soluble in pH ~9.0 aqueous solution, were applied to measure Cr(VI) in ambient PM10 collected from three urban areas and one suburban area in New Jersey. The total Cr(VI) concentrations were 1.05–1.41 ng/m3 in the winter and 0.99–1.56 ng/m3 in the summer. The soluble Cr(VI) concentrations were 0.03–0.19 ng/m3 in the winter and 0.12–0.37 ng/m3 in the summer. The summer mean ratios of soluble to total Cr(VI) were 14.3–43.7%, significantly higher than 4.2–14.4% in the winter. The winter concentrations of soluble and total Cr(VI) in the suburban area were significantly lower than in the three urban areas. The results suggested that formation of Cr(VI) via atmospheric chemistry may contribute to the higher soluble Cr(VI) concentrations in the summer. PMID:26120324

  8. Push-pull slab coupled optical sensor for measuring electric fields in a vibrational environment.

    Science.gov (United States)

    Seng, Frederick; Stan, Nikola; Josephson, Chad; King, Rex; Shumway, LeGrand; Selfridge, Richard; Schultz, Stephen

    2015-06-01

    Vibration-insensitive fiber optic electric field sensor is created by fabricating two sensing elements in close proximity onto the same optical fiber and subtracting the two signals. The device is used to measure an electric field of 10  kV/m, while the sensor is being bent and impacted. PMID:26192684

  9. Selection of optimal threshold to construct recurrence plot for structural operational vibration measurements

    Science.gov (United States)

    Yang, Dong; Ren, Wei-Xin; Hu, Yi-Ding; Li, Dan

    2015-08-01

    The structural health monitoring (SHM) involves the sampled operational vibration measurements over time so that the structural features can be extracted accordingly. The recurrence plot (RP) and corresponding recurrence quantification analysis (RQA) have become a useful tool in various fields due to its efficiency. The threshold selection is one of key issues to make sure that the constructed recurrence plot contains enough recurrence points. Different signals have in nature different threshold values. This paper is aiming at presenting an approach to determine the optimal threshold for the operational vibration measurements of civil engineering structures. The surrogate technique and Taguchi loss function are proposed to generate reliable data and to achieve the optimal discrimination power point where the threshold is optimum. The impact of selecting recurrence thresholds on different signals is discussed. It is demonstrated that the proposed method to identify the optimal threshold is applicable to the operational vibration measurements. The proposed method provides a way to find the optimal threshold for the best RP construction of structural vibration measurements under operational conditions.

  10. Measurements and analysis of vibrations at Virilla Bridge, national route N° 1

    Directory of Open Access Journals (Sweden)

    Francisco Navarro-Henríquez

    2015-06-01

    The measurements allowed quantifying the vibration magnitudes and deformation in various sections of the bridge, on condition of vehicular traffic service (environmental performance. The experimental results are compared with computational analytical modeling of the structure and also with national and international standards.

  11. Subspace identification of wind turbine shaft vibrations measured with a piezoelectric sensor

    Directory of Open Access Journals (Sweden)

    Dominik Kujawa

    Full Text Available The paper presents a new approach to the parameter identification of a wind turbine shaft vibrations measured with piezoelectric sensor. The system order and unknown processes matrices are determined using the wind force as the model input and wind turbin ...

  12. Analysis of a Mechanical System’s Dynamic Proper-ties by Vibrations Measurements

    Directory of Open Access Journals (Sweden)

    Radu Panaitescu-Liess

    2010-01-01

    Full Text Available This paper aims to present some theoretical notions about the solution of the reverse problem in the dynamic response study of a mechanical system. Thus, by measuring vibration, some dynamic properties of the mechanical system considered can be determined.

  13. Interior noise and vibration measurements on operational military helicopters and comparisons with various ride quality criteria

    Science.gov (United States)

    Clevenson, S. A.; Leatherwood, J. D.; Hollenbaugh, D. D.

    1983-01-01

    The results of physical measurements of the interior noise and vibration obtained within eight operational military helicopters are presented. The data were extensively analyzed and are presented in the following forms: noise and vibration spectra, overall root-mean-square acceleration levels in three linear axes, peak accelerations at dominant blade passage frequencies, acceleration exceedance data, and overall and ""A'' weighted sound pressure levels. Peak acceleration levels were compared to the ISO 1-hr reduced comfort and fatigue decreased proficiency boundaries and the NASA discomfort criteria. The ""A'' weighted noise levels were compared to the NASA annoyance criteria, and the overall noise spectra were compared to MIL-STD-1294 (""Acoustical Noise Limits in Helicopters''). Specific vibration components at blade passage frequencies for several aircraft exceeded both the ISO reduced comfort boundary and the NASA passenger discomfort criteria. The ""A'' weighted noise levels, corrected for SPH-4 helmet attenuation characteristics, exceeded the NASA annoyance threshold for several aircraft.

  14. Piping vibration management combining measurements and numerical simulation

    International Nuclear Information System (INIS)

    In an ongoing project a practical method is being developed to monitor the condition and remaining lifetime of process piping. This method combines both measurements - using a minimum number of fixed continuous measurements - and an adequate computational model. Relatively simple piping was chosen as the first pilot analysis case. This paper outlines the contents of the project and describes the finite element analyses, based on design documents, detailed observation of the piping geometry and supports and results obtained by updated FE (finite element) model. (orig.)

  15. Ultrafast Measurements of Coherent Vibrations in Benzenethiol Monolayer Film

    Directory of Open Access Journals (Sweden)

    Takeda J.

    2013-03-01

    Full Text Available Ultrafast photo-reflectance at a monolayer film of benzentiol molecule adsorbed on a gold surface was measured by means of pump-probe method using an ultrashort pulse laser. The surface-sensitive transient response in THz region revealed coherent motion of the molecules affected by the adsorption.

  16. Measurement of vibration rate of manually operated percussion machines

    Science.gov (United States)

    Aleksandrov, Y. V.; Flavitskiy, Y. V.

    1973-01-01

    A special apparatus for measurement of accelerations of between 1 and 5000 g and shock stress pulses from 20 kg/cu cm up, with durations of 50.1 million sec and higher was designed and built. The amplitudes and shapes of the peak vibroshock pulses, arising during operation of a hammer, are obtained; the recording time of the continuous process is determined by the time of one revolution of the drum of a specially made mechanical photo attachment.

  17. Direct measurement of time dependent diffusion for Ag and Au under ambient conditions

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Pil Sun; Jo, Han Yeol; Kim, Tae Kyeong [Hankuk University of Foreign Studies, Yongin (Korea, Republic of)

    2014-12-15

    Time-dependent diffusion for Ag and Au metal atoms was measured using the scanning tunneling microscope break-junction technique in ambient conditions. We observed that Ag contacts do not form long single-atomic chains compared to Au contacts during the elongation of each metal electrode, and Ag atoms diffuse more quickly than Au atoms after metal contact rupture. This is consistent with previous results of molecular dynamic simulations. Further, we found a correlation between diffusion length and the evolution time on an atomic scale to reveal the time-dependent diffusion for Ag and Au metal atoms.

  18. Measurement of ambient aerosol hydration state at Great Smoky Mountains National Park in the Southeastern United States

    Directory of Open Access Journals (Sweden)

    N. F. Taylor

    2011-08-01

    Full Text Available We present results from two field deployments of a unique tandem differential mobility analyzer (TDMA configuration with two primary capabilities: identifying alternative stable or meta-stable ambient aerosol hydration states associated with hysteresis in aerosol hydration behavior and determining the actual Ambient hydration State (AS-TDMA. This data set is the first to fully classify the ambient hydration state of aerosols despite recognition that hydration state significantly impacts the roles of aerosols in climate, visibility and heterogeneous chemistry. The AS-TDMA was installed at a site in eastern Tennessee on the border of Great Smoky Mountains National Park for projects during the summer of 2006 and winter of 2007–2008. During the summer, 12 % of the aerosols sampled in continuous AS-TDMA measurements were found to posses two possible hydration states under ambient conditions. In every case, the more hydrated of the possible states was occupied. The remaining 88 % did not posses multiple possible states. In continuous measurements during the winter, 49 % of the aerosols sampled possessed two possible ambient hydration states; the remainder possessed only one. Of those aerosols with multiple possible ambient hydration states, 65 % occupied the more hydrated state; 35 % occupied the less hydrated state. This seasonal contrast is supported by differences in the fine particulate (PM2.5 composition and ambient RH as measured during the two study periods. In addition to seasonal summaries, this work includes case studies depicting the variation of hydration state with changing atmospheric conditions.

  19. Measurement of ambient aerosol hydration state at Great Smoky Mountains National Park in the southeastern United States

    Directory of Open Access Journals (Sweden)

    N. F. Taylor

    2011-12-01

    Full Text Available We present results from two field deployments of a unique tandem differential mobility analyzer (TDMA configuration with two primary capabilities: identifying alternative stable or meta-stable ambient aerosol hydration states associated with hysteresis in aerosol hydration behavior and determining the actual Ambient hydration State (AS-TDMA. This data set is the first to fully classify the ambient hydration state of aerosols despite recognition that hydration state significantly impacts the roles of aerosols in climate, visibility and heterogeneous chemistry. The AS-TDMA was installed at a site in eastern Tennessee on the border of Great Smoky Mountains National Park for projects during the summer of 2006 and winter of 2007–2008. During the summer, 12% of the aerosols sampled in continuous AS-TDMA measurements were found to posses two possible hydration states under ambient conditions. In every case, the more hydrated of the possible states was occupied. The remaining 88% did not posses multiple possible states. In continuous measurements during the winter, 49% of the aerosols sampled possessed two possible ambient hydration states; the remainder possessed only one. Of those aerosols with multiple possible ambient hydration states, 65% occupied the more hydrated state; 35% occupied the less hydrated state. This seasonal contrast is supported by differences in the fine particulate (PM2.5 composition and ambient RH as measured during the two study periods. In addition to seasonal summaries, this work includes case studies depicting the variation of hydration state with changing atmospheric conditions.

  20. Vibration measurement of electrical machines using integrated fibre Bragg gratings

    Science.gov (United States)

    Fabian, M.; Borg Bartolo, J.; Ams, M.; Gerada, C.; Sun, T.; Grattan, K. T. V.

    2015-09-01

    In this paper a method to track the rotating force vector set up within the air-gap of radial flux rotating electrical machines using fibre Bragg gratings is reported. The proposed technique offers the potential for simultaneous rotor speed and position monitoring. This specific sensor design, together with other FBG-based multi-parameter measurements, is aimed to create an all-optical sensor solution for electrical machines, reducing the component count of existing systems and addressing noise issues traditionally associated with electrical sensors used. In this work, an optical fibre sensor system has been successfully integrated into an off-the-shelf four-pole 11kW induction motor.

  1. The Comparative Reactivity Method – a new tool to measure total OH reactivity in ambient air

    Directory of Open Access Journals (Sweden)

    J. Lelieveld

    2007-12-01

    Full Text Available Hydroxyl (OH radicals play a vital role in maintaining the oxidizing capacity of the atmosphere. To understand variations in OH radicals both source and sink terms must be understood. Currently the overall sink term, or the total atmospheric reactivity to OH, is poorly constrained. Here, we present a new on-line method to directly measure the total OH reactivity (i.e.~total loss rate of OH radicals in a sampled air mass. In this method, a reactive molecule (X, not normally present in air, is passed through a glass reactor and its concentration is monitored with a suitable detector. OH radicals are then introduced in the glass reactor at a constant rate to react with X, first in the presence of zero air and then in the presence of ambient air containing VOCs and other OH reactive species. Comparing the amount of X exiting the reactor with and without the ambient air allows the air reactivity to be determined. In our existing set up, X is pyrrole and the detector used is a proton transfer reaction mass spectrometer. The present dynamic range for ambient air reactivity is about 6 to 300 s−1. The system has been tested and calibrated with different single and mixed hydrocarbon standards showing excellent linearity and accountability with the reactivity of the standards. Field tests in the tropical rainforest of Suriname (~53 s−1 and the urban atmosphere of Mainz (~10 s−1 Germany, show the promise of the new method and indicate that a significant fraction of OH reactive species in the tropical forests is likely missed by current measurements. Suggestions for improvements to the technique and future applications are discussed.

  2. Measuring electric fields and noncovalent interactions using the vibrational stark effect.

    Science.gov (United States)

    Fried, Stephen D; Boxer, Steven G

    2015-04-21

    Over the past decade, we have developed a spectroscopic approach to measure electric fields inside matter with high spatial (field (electric fields. Therefore, the frequency of a vibrational probe encodes information about the local electric field in the vicinity around the probe. The VSE method has enabled us to understand in great detail the underlying physical nature of several important biomolecular phenomena, such as drug-receptor selectivity in tyrosine kinases, catalysis by the enzyme ketosteroid isomerase, and unidirectional electron transfer in the photosynthetic reaction center. Beyond these specific examples, the VSE has provided a conceptual foundation for how to model intermolecular (noncovalent) interactions in a quantitative, consistent, and general manner. The starting point for research in this area is to choose (or design) a vibrational probe to interrogate the particular system of interest. Vibrational probes are sometimes intrinsic to the system in question, but we have also devised ways to build them into the system (extrinsic probes), often with minimal perturbation. With modern instruments, vibrational frequencies can increasingly be recorded with very high spatial, temporal, and frequency resolution, affording electric field maps correspondingly resolved in space, time, and field magnitude. In this Account, we set out to explain the VSE in broad strokes to make its relevance accessible to chemists of all specialties. Our intention is not to provide an encyclopedic review of published work but rather to motivate the underlying framework of the methodology and to describe how we make and interpret the measurements. Using certain vibrational probes, benchmarked against computer models, it is possible to use the VSE to measure absolute electric fields in arbitrary environments. The VSE approach provides an organizing framework for thinking generally about intermolecular interactions in a quantitative way and may serve as a useful conceptual tool

  3. Analysis of classical guitars' vibrational behavior based on scanning laser vibrometer measurements

    Science.gov (United States)

    Czajkowska, Marzena

    2012-06-01

    One of the main goals in musical acoustics research is to link measurable, physical properties of a musical instrument with subjective assessments of its tone quality. The aim of the research discussed in this paper was to observe the structural vibrations of different class classical guitars in relation to their quality. This work focuses on mid-low-and low-class classical (nylon-stringed) guitars. The main source of guitar body vibrations come from top and back plate vibrations therefore these were the objects of structural mode measurements and analysis. Sixteen classical guitars have been investigated, nine with cedar and seven with spruce top plate. Structural modes of top and back plates have been measured with the aid of a scanning laser vibrometer and the instruments were excited with a chirp signal transferred by bone vibrator. The issues related to excitor selection have been discussed. Correlation and descriptive statistics of top and back plates measurement results have been investigated in relation to guitar quality. The frequency range of 300 Hz to 5 kHz as well as selected narrowed frequency bands have been analyzed for cedar and spruce guitars. Furthermore, the influence of top plate wood type on vibration characteristics have been observed on three pairs of guitars. The instruments were of the same model but different top plate material. Determination and visualization of both guitar plates' modal patterns in relation to frequency are a significant attainment of the research. Scanning laser vibrometer measurements allow particular mode observation and therefore mode identification, as opposed to sound pressure response measurements. When correlating vibration characteristics of top and back plates it appears that Pearson productmoment correlation coefficient is not a parameter that associates with guitar quality. However, for best instruments with cedar top, top-back correlation coefficient has relatively greater value in 1-2 kHz band and lower in

  4. An Evaluation of Uncertainty Associated to Analytical Measurements of Selected Polycyclic Aromatic Compounds in Ambient Air

    International Nuclear Information System (INIS)

    This paper presents an evaluation of uncertainty associated to analytical measurement of eighteen polycyclic aromatic compounds (PACs) in ambient air by liquid chromatography with fluorescence detection (HPLC/FD). The study was focused on analyses of PM10, PM2.5 and gas phase fractions. Main analytical uncertainty was estimated for eleven polycyclic aromatic hydrocarbons (PAHs), four nitro polycyclic aromatic hydrocarbons (nitro-PAHs) and two hydroxy polycyclic aromatic hydrocarbons (OH-PAHs) based on the analytical determination, reference material analysis and extraction step. Main contributions reached 15-30% and came from extraction process of real ambient samples, being those for nitro- PAHs the highest (20-30%). Range and mean concentration of PAC mass concentrations measured in gas phase and PM10/PM2.5 particle fractions during a full year are also presented. Concentrations of OH-PAHs were about 2-4 orders of magnitude lower than their parent PAHs and comparable to those sparsely reported in literature. (Author)

  5. Estimates of site response based on spectral ratio between horizontal and vertical components of ambient vibrations in the source zone of 2001 Bhuj earthquake

    Science.gov (United States)

    Natarajan, Thulasiraman; Rajendran, Kusala

    2015-02-01

    We investigated the site response characteristics of Kachchh rift basin over the meizoseismal area of the 2001, Mw 7.6, Bhuj (NW India) earthquake using the spectral ratio of the horizontal and vertical components of ambient vibrations. Using the available knowledge on the regional geology of Kachchh and well documented ground responses from the earthquake, we evaluated the H/V curves pattern across sediment filled valleys and uplifted areas generally characterized by weathered sandstones. Although our H/V curves showed a largely fuzzy nature, we found that the hierarchical clustering method was useful for comparing large numbers of response curves and identifying the areas with similar responses. Broad and plateau shaped peaks of a cluster of curves within the valley region suggests the possibility of basin effects within valley. Fundamental resonance frequencies (f0) are found in the narrow range of 0.1-2.3 Hz and their spatial distribution demarcated the uplifted regions from the valleys. In contrary, low H/V peak amplitudes (A0 = 2-4) were observed on the uplifted areas and varying values (2-9) were found within valleys. Compared to the amplification factors, the liquefaction indices (kg) were able to effectively indicate the areas which experienced severe liquefaction. The amplification ranges obtained in the current study were found to be comparable to those obtained from earthquake data for a limited number of seismic stations located on uplifted areas; however the values on the valley region may not reflect their true amplification potential due to basin effects. Our study highlights the practical usefulness as well as limitations of the H/V method to study complex geological settings as Kachchh.

  6. Validation of emission inventories by measurements of ambient volatile organic compounds in Beijing, China

    Directory of Open Access Journals (Sweden)

    M. Wang

    2013-10-01

    Full Text Available Understanding the sources of volatile organic compounds (VOCs is essential for ground-level ozone and secondary organic aerosols (SOA abatement measures. We made measurements at 28 sites and online observations at an urban site in Beijing from July 2009 to January 2012. From these we determined the spatial and temporal distributions of VOCs, estimated their annual emission strengths based on their emission ratios relative to CO, and quantified the relative contributions of various sources using the chemical mass balance (CMB model. The results from ambient measurements were compared with existing emission inventories to evaluate the spatial distribution, species-specific emissions, and source structure of VOCs. The measured VOC distributions revealed a hotspot in the southern suburban area of Beijing, whereas current emission inventories suggested that VOC emissions were concentrated in downtown areas. Compared with results derived from ambient measurements, the annual inventoried emissions of oxygenated VOC (OVOC species and C2–C4 alkanes might be underestimated, while the emissions of styrene and 1,3-butadiene might be overestimated by current inventories. Source apportionment using the CMB model identified vehicular exhaust as the most important VOC source, contributing 46%, in good agreement with the 40–51% assumed by emission inventories. However, the relative contribution of solvent and paint usage obtained from the CMB model was only 5%, significantly lower than the values reported by emission inventories (14–32%. Meanwhile, the relative contribution of industrial processes calculated using the CMB model was 17%, slightly higher than that in emission inventories. These results suggested that VOCs emission strengths in southern suburban area of Beijing, annual emissions of alkenes and OVOCs, and the contributions of solvent and paint usage and industrial processes in current inventories, all require significant revision.

  7. Raman Channel Temperature Measurement of SiC MESFET as a Function of Ambient Temperature and DC Power

    Science.gov (United States)

    Ponchak, George E.; Eldridge, Jeffrey J.; Krainsky, Isay L.

    2009-01-01

    Raman spectroscopy is used to measure the junction temperature of a Cree SiC MESFET as a function of the ambient temperature and DC power. The carrier temperature, which is approximately equal to the ambient temperature, is varied from 25 C to 450 C, and the transistor is biased with VDS=10V and IDS of 50 mA and 100 mA. It is shown that the junction temperature is approximately 52 and 100 C higher than the ambient temperature for the DC power of 500 and 1000 mW, respectively.

  8. A MEMS Resonant Sensor to Measure Fluid Density and Viscosity under Flexural and Torsional Vibrating Modes.

    Science.gov (United States)

    Zhao, Libo; Hu, Yingjie; Wang, Tongdong; Ding, Jianjun; Liu, Xixiang; Zhao, Yulong; Jiang, Zhuangde

    2016-01-01

    Methods to calculate fluid density and viscosity using a micro-cantilever and based on the resonance principle were put forward. Their measuring mechanisms were analyzed and the theoretical equations to calculate the density and viscosity were deduced. The fluid-solid coupling simulations were completed for the micro-cantilevers with different shapes. The sensing chips with micro-cantilevers were designed based on the simulation results and fabricated using the micro electromechanical systems (MEMS) technology. Finally, the MEMS resonant sensor was packaged with the sensing chip to measure the densities and viscosities of eight different fluids under the flexural and torsional vibrating modes separately. The relative errors of the measured densities from 600 kg/m³ to 900 kg/m³ and viscosities from 200 μPa·s to 1000 μPa·s were calculated and analyzed with different microcantilevers under various vibrating modes. The experimental results showed that the effects of the shape and vibrating mode of micro-cantilever on the measurement accuracies of fluid density and viscosity were analyzed in detail. PMID:27275823

  9. IEEE 802.11-Based Wireless Sensor System for Vibration Measurement

    Directory of Open Access Journals (Sweden)

    Yutaka Uchimura

    2010-01-01

    Full Text Available Network-based wireless sensing has become an important area of research and various new applications for remote sensing are expected to emerge. One of the promising applications is structural health monitoring of building or civil engineering structure and it often requires vibration measurement. For the vibration measurement via wireless network, time synchronization is indispensable. In this paper, we introduce a newly developed time synchronized wireless sensor network system. The system employs IEEE 802.11 standard-based TSF-counter and sends the measured data with the counter value. TSF based synchronization enables consistency on common clock among different wireless nodes. We consider the scale effect on synchronization accuracy and evaluated the effect by taking beacon collisions into account. The scalability issue by numerical simulations is also studied. This paper also introduces a newly developed wireless sensing system and the hardware and software specifications are introduced. The experiments were conducted in a reinforced concrete building to evaluate synchronization accuracy. The developed system was also applied for a vibration measurement of a 22-story steel structured high rise building. The experimental results showed that the system performed more than sufficiently.

  10. A MEMS Resonant Sensor to Measure Fluid Density and Viscosity under Flexural and Torsional Vibrating Modes

    Science.gov (United States)

    Zhao, Libo; Hu, Yingjie; Wang, Tongdong; Ding, Jianjun; Liu, Xixiang; Zhao, Yulong; Jiang, Zhuangde

    2016-01-01

    Methods to calculate fluid density and viscosity using a micro-cantilever and based on the resonance principle were put forward. Their measuring mechanisms were analyzed and the theoretical equations to calculate the density and viscosity were deduced. The fluid-solid coupling simulations were completed for the micro-cantilevers with different shapes. The sensing chips with micro-cantilevers were designed based on the simulation results and fabricated using the micro electromechanical systems (MEMS) technology. Finally, the MEMS resonant sensor was packaged with the sensing chip to measure the densities and viscosities of eight different fluids under the flexural and torsional vibrating modes separately. The relative errors of the measured densities from 600 kg/m3 to 900 kg/m3 and viscosities from 200 μPa·s to 1000 μPa·s were calculated and analyzed with different microcantilevers under various vibrating modes. The experimental results showed that the effects of the shape and vibrating mode of micro-cantilever on the measurement accuracies of fluid density and viscosity were analyzed in detail. PMID:27275823

  11. A MEMS Resonant Sensor to Measure Fluid Density and Viscosity under Flexural and Torsional Vibrating Modes

    Directory of Open Access Journals (Sweden)

    Libo Zhao

    2016-06-01

    Full Text Available Methods to calculate fluid density and viscosity using a micro-cantilever and based on the resonance principle were put forward. Their measuring mechanisms were analyzed and the theoretical equations to calculate the density and viscosity were deduced. The fluid-solid coupling simulations were completed for the micro-cantilevers with different shapes. The sensing chips with micro-cantilevers were designed based on the simulation results and fabricated using the micro electromechanical systems (MEMS technology. Finally, the MEMS resonant sensor was packaged with the sensing chip to measure the densities and viscosities of eight different fluids under the flexural and torsional vibrating modes separately. The relative errors of the measured densities from 600 kg/m3 to 900 kg/m3 and viscosities from 200 μPa·s to 1000 μPa·s were calculated and analyzed with different microcantilevers under various vibrating modes. The experimental results showed that the effects of the shape and vibrating mode of micro-cantilever on the measurement accuracies of fluid density and viscosity were analyzed in detail.

  12. A hybrid Φ/B-OTDR for simultaneous vibration and strain measurement

    Science.gov (United States)

    Peng, Fei; Cao, Xuli

    2016-06-01

    A hybrid phase-sensitive optical time domain reflectometry (Φ-OTDR) and Brillouin optical time domain reflectometry (B-OTDR) system which can realize simultaneous measurement of both dynamic vibration and static strain is proposed. Because the Rayleigh scattering light and spontaneous Brilliouin scattering light are naturally frequency-multiplexed, the heterodyne asynchronous demodulation of frequency shift keying (FSK) in optical fiber communications is utilized, and the demodulations of the two scattering signals are synchronized. In addition, the forward Raman amplification is introduced to the system, which not only makes up for the deficiency of spontaneous Brilliouin scattering based distributed fiber sensor, but also has the merit of the single end measurement of B-OTDR. The designed Φ/B-OTDR hybrid system has the sensing range of 49 km with 10 m spatial resolution. The vibration and strain experiments show that this hybrid system has great potential for use in long-distance structural health monitoring.

  13. Hybrid predictions of railway induced ground vibration using a combination of experimental measurements and numerical modelling

    Science.gov (United States)

    Kuo, K. A.; Verbraken, H.; Degrande, G.; Lombaert, G.

    2016-07-01

    Along with the rapid expansion of urban rail networks comes the need for accurate predictions of railway induced vibration levels at grade and in buildings. Current computational methods for making predictions of railway induced ground vibration rely on simplifying modelling assumptions and require detailed parameter inputs, which lead to high levels of uncertainty. It is possible to mitigate against these issues using a combination of field measurements and state-of-the-art numerical methods, known as a hybrid model. In this paper, two hybrid models are developed, based on the use of separate source and propagation terms that are quantified using in situ measurements or modelling results. These models are implemented using term definitions proposed by the Federal Railroad Administration and assessed using the specific illustration of a surface railway. It is shown that the limitations of numerical and empirical methods can be addressed in a hybrid procedure without compromising prediction accuracy.

  14. New high-temperature transducer for sound and vibration measurements in nuclear power stations

    International Nuclear Information System (INIS)

    With the ever increasing demands made concerning the monitoring of nuclear power stations, sound and vibration measurement is of growing importance. Prerequisites for its successful application are transducers of sufficient sensitivity, high-temperature, radiation and corrosion resistivity, as well as high reliability. In sodium-cooled nuclear power stations, these transducers may be used for integral and local boiling detection. Vibration and sound measurements in all types of nuclear power stations have lately begun to play an important part, too. The different conditions of application in sodium-cooled fast breeders, light-water-cooled plants, and high-temperature nuclear power stations can be accounted for by two physical methods: the piezoelectric and the magnetostrictive technique. Both of these methods are discussed. (orig./AK)

  15. A Procedure for Accurately Measuring the Shaker Overturning Moment During Random Vibration Tests

    Science.gov (United States)

    Nayeri, Reza D.

    2011-01-01

    Motivation: For large system level random vibration tests, there may be some concerns about the shaker's capability for the overturning moment. It is the test conductor's responsibility to predict and monitor the overturning moment during random vibration tests. If the predicted moment is close to the shaker's capability, test conductor must measure the instantaneous moment at low levels and extrapolate to higher levels. That data will be used to decide whether it is safe to proceed to the next test level. Challenge: Kistler analog formulation for computing the real-time moment is only applicable to very limited cases in which we have 3 or 4 load cells installed at shaker interface with hardware. Approach: To overcome that limitation, a simple procedure was developed for computing the overturning moment time histories using the measured time histories of the individual load cells.

  16. Influence of ambient temperature on whole body and segmental bioimpedance spectroscopy measurements

    Science.gov (United States)

    Medrano, G.; Bausch, R.; Ismail, A. H.; Cordes, A.; Pikkemaat, R.; Leonhardt, S.

    2010-04-01

    Bioimpedance spectroscopy (BIS) measurements are easy to implement and could be used for continuous monitoring. However, several factors (e.g. environment temperature) influence the measurements limiting the accuracy of the technology. Changes in skin temperature produced by changes in ambient temperature are related with changes in skin blood flow and skin impedance. It is assumed that skin impedance change is responsible for the error observed in whole body and segmental measurements. Measurements including body parts more distant from the torso seem to be more affected. In the present article skin and segment impedance have been performed on healthy subjects under extreme changes in environment temperature (13-39 °C). A commercial BIS device with a range between 5 kHz and 1 MHz has been used for the measurements. The results indicate that not only skin impedance, but also impedance of deeper tissue (e.g. muscle) may be responsible for the influence of environment temperature on BIS measurements. Segmental (knee-to-knee) BIS measurements show a relative change of only 2 %, while forearm and whole body impedance changed 14 % and 8 % respectively.

  17. Self-mixing digital closed-loop vibrometer for high accuracy vibration measurements

    Science.gov (United States)

    Magnani, Alessandro; Melchionni, Dario; Pesatori, Alessandro; Norgia, Michele

    2016-04-01

    The novelty of Self-mixing interferometry is represented by the combination of high accuracy and contactless operation with compact, very-low-cost and user-friendly setup. This paper introduces state of the art techniques to monitor vibrations focusing on a novel digital feedback vibrometer. It exploits a control loop to delete interferometric signal distortion and improve measurement accuracy. A digital implementation is proposed to enhance system performances through a real-time elaboration.

  18. Measurement of Ambient Air Particle (TSP, PM10, PM2,5) Around Candidate Location of PLTN Semenanjung Lemahabang

    International Nuclear Information System (INIS)

    Measurement analysis of ambient air particle (TSP, PM10, PM2,5) around location candidate of PLTN (Power Station of Nuclear Energy) Semenanjung Lemahabang has been carried out. The measurement was conducted in May 2007 with a purpose to providing information about concentration of ambient air particle (TSP, PM10, PM2,5) and diameter distribution of its air particle. The measurement was conducted in three locations i.e. 1). Balong village 2). Bayuran 3). Bondo. Concentration of TSP, PM10, and PM2,5 per 24 hours in all measured locations in area candidate of PLTN exceed quality standard of national ambient air is specified by government. All measurement locations for the TSP, PM10, and PM2,5 was include category of ISPU (Standard Index of Air Pollution) moderate. (author)

  19. LDV measurement of bird ear vibrations to determine inner ear impedance and middle ear power flow

    Science.gov (United States)

    Muyshondt, Pieter G. G.; Pires, Felipe; Dirckx, Joris J. J.

    2016-06-01

    The mechanical behavior of the middle ear structures in birds and mammals is affected by the fluids in the inner ear (IE) that are present behind the oval window. In this study, the aim was to gather knowledge of the acoustic impedance of the IE in the ostrich, to be able to determine the effect on vibrations and power flow in the single-ossicle bird middle ear for future studies. To determine the IE impedance, vibrations of the ossicle were measured for both the quasi-static and acoustic stimulus frequencies. In the acoustic regime, vibrations were measured with a laser Doppler vibrometer and electromagnetic stimulation of the ossicle. The impedance of the inner ear could be determined by means of a simple RLC model in series, which resulted in a stiffness reactance of KIE = 0.20.1012 Pa/m3, an inertial impedance of MIE = 0.652.106 Pa s2/m3, and a resistance of RIE = 1.57.109 Pa s/m. The measured impedance is found to be considerably smaller than what is found for the human IE.

  20. Improved Holographic Method for Vibration Amplitude Measurement from Nano to Microscale

    Czech Academy of Sciences Publication Activity Database

    Psota, Pavel; Lédl, Vít; Doleček, Roman; Václavík, Jan; Kopecký, V.

    Vol. 1600. New York : American Institute of Physics Inc, 2014 - (Tomasini, E.), s. 228-236 ISBN 978-0-7354-1234-7. ISSN 0094-243X. - (1600). [International Conference on Vibration Measurements by Laser and Noncontact Techniques - AIVELA 2014/11./. Ancona (IT), 25.06.2014-27.06.2014] R&D Projects: GA ČR GA13-10365S Institutional support: RVO:61389021 Keywords : Amplitude measurement * Digital holography * Full-field reconstruction Subject RIV: JB - Sensors, Measurment, Regulation http://scitation.aip.org/content/aip/proceeding/aipcp/10.1063/1.4879587

  1. A concept of an automated function control for ambient aerosol measurements using mobility particle size spectrometers

    Science.gov (United States)

    Bastian, S.; Löschau, G.; Wiedensohler, A.

    2014-04-01

    An automated function control unit was developed to regularly check the ambient particle number concentration derived from a mobility particle size spectrometer as well as its zero-point behaviour. The function control allows unattended quality assurance experiments at remote air quality monitoring or research stations under field conditions. The automated function control also has the advantage of being able to get a faster system stability response than the recommended on-site comparisons with reference instruments. The method is based on a comparison of the total particle number concentration measured by a mobility particle size spectrometer and a condensation particle counter while removing diffusive particles smaller than 20 nm in diameter. In practice, the small particles are removed by a set of diffusion screens, as traditionally used in a diffusion battery. Another feature of the automated function control is to check the zero-point behaviour of the ambient aerosol passing through a high-efficiency particulate air (HEPA) filter. The performance of the function control is illustrated with the aid of a 1-year data set recorded at Annaberg-Buchholz, a station in the Saxon air quality monitoring network. During the period of concern, the total particle number concentration derived from the mobility particle size spectrometer slightly overestimated the particle number concentration recorded by the condensation particle counter by 2 % (grand average). Based on our first year of experience with the function control, we developed tolerance criteria that allow a performance evaluation of a tested mobility particle size spectrometer with respect to the total particle number concentration. We conclude that the automated function control enhances the quality and reliability of unattended long-term particle number size distribution measurements. This will have beneficial effects for intercomparison studies involving different measurement sites, and help provide a higher

  2. On measuring surface wave phase velocity from station–station cross-correlation of ambient signal

    DEFF Research Database (Denmark)

    Boschi, Lapo; Weemstra, Cornelis; Verbeke, Julie;

    2012-01-01

    We apply two different algorithms to measure surface wave phase velocity, as a function of frequency, from seismic ambient noise recorded at pairs of stations from a large European network. The two methods are based on consistent theoretical formulations, but differ in the implementation: one...... method involves the time-domain cross-correlation of signal recorded at different stations; the other is based on frequency-domain cross-correlation, and requires finding the zero-crossings of the real part of the cross-correlation spectrum. Furthermore, the time-domain method, as implemented here and in...... the literature, practically involves the important approximation that interstation distance be large compared to seismic wavelength. In both cases, cross-correlations are ensemble-averaged over a relatively long period of time (1 yr). We verify that the two algorithms give consistent results, and...

  3. Measurement of major ambient air pollution components at sub-urban area of Karachi

    International Nuclear Information System (INIS)

    Base line study for the measurement of major ambient air pollution components such as O/sub 3/, SO/sub 2/, CO, NO, NO/sub x/,PM10, methane, non-methane along with the meteorological parameters was carried out by air pollution Monitoring Mobile Laboratory at an urban back ground site of Karachi. The average concentration of O/sub 3/ was found to be between 4.62 and 20.36 ppb, SO/sub 2/ 0.73 and 4.69 ppb, CO 0.14 and 0.77 ppm. NO 0.92 and 2.73 ppb, NO/sub x/ 3.1 and 7.5 ppb, PM10 142 and 251 mu g m/sup -3/, methane 1.09 and 2.7 ppm, non-methane hydrocarbon 0.41 and 0.96 ppm. (author)

  4. Measurement of mechanical quality factors of polymers in flexural vibration for high-power ultrasonic application.

    Science.gov (United States)

    Wu, Jiang; Mizuno, Yosuke; Tabaru, Marie; Nakamura, Kentaro

    2016-07-01

    A method for measuring the mechanical quality factor (Q factor) of materials in large-amplitude flexural vibrations was devised on the basis of the original definition of the Q factor. The Q factor, the ratio of the reactive energy to the dissipated energy, was calculated from the vibration velocity distribution. The bar thickness was selected considering the effect of the thickness on the estimation error. In the experimental setup, a 1-mm-thick polymer-based bar was used as a sample and fixed on the top of a longitudinal transducer. Using transducers of different lengths, flexural waves in the frequency range of 20-90kHz were generated on the bar. The vibration strain in the experiment reached 0.06%. According to the Bernoulli-Euler model, the reactive energy and dissipated energy were estimated from the vertical velocity distribution on the bar, and the Q factors were measured as the driving frequency and strain were varied. The experimental results showed that the Q factors decrease as the driving frequencies and strains increase. At a frequency of 28.30kHz, the Q factor of poly(phenylene sulfide) (PPS) reached approximately 460 when the strain was smaller than 0.005%. PPS exhibited a much higher Q factor than the other tested polymers, which implies that it is a potentially applicable material as the elastomer for high-power ultrasonic devices. PMID:27065470

  5. Low frequency noise and vibrations measurements at a modern wind farm

    International Nuclear Information System (INIS)

    Low frequency noise and vibration levels at a modern wind farm have been measured at distances up to 1km. Noise and vibration levels have been found to comply with recommended residential criteria even on the wind turbine site itself and the acoustic signal is below accepted thresholds of perception below 20 Hz. Nevertheless low level infrasonic, periodic noise from the windfarm may occasionally be detected by instrumentation at distances up to 1 km, despite other sources of noise. Subjective detection of the wind turbines may also be just apparent at this distance but is due to higher frequency components. A greater knowledge of building sound transmission functions would be useful in assessing the effects of both audible and infrasonic noise inside dwellings. (author)

  6. Measurement of the ambient organic aerosol volatility distribution: application during the Finokalia Aerosol Measurement Experiment (FAME-2008

    Directory of Open Access Journals (Sweden)

    B. H. Lee

    2010-07-01

    Full Text Available A variable residence time thermodenuder (TD was combined with an Aerodyne Aerosol Mass Spectrometer (AMS and a Scanning Mobility Particle Sizer (SMPS to measure the volatility distribution of aged organic aerosol in the Eastern Mediterranean during the Finokalia Aerosol Measurement Experiment in May of 2008 (FAME-2008. A new method for the quantification of the organic aerosol volatility distribution was developed combining measurements of all three instruments together with an aerosol dynamics model.

    Challenges in the interpretation of ambient thermodenuder-AMS measurements include the potential resistances to mass transfer during particle evaporation, the effects of particle size on the evaporated mass fraction, the changes in the AMS collection efficiency and particle density as the particles evaporate partially in the TD, and finally potential losses inside the TD. Our proposed measurement and data analysis method accounts for all of these problems combining the AMS and SMPS measurements.

    The AMS collection efficiency of the aerosol that passed through the TD was found to be approximately 10% lower than the collection efficiency of the aerosol that passed through the bypass. The organic aerosol measured at Finokalia is approximately 2 orders of magnitude less volatile than fresh laboratory-generated biogenic secondary organic aerosol. This low volatility is consistent with its highly oxygenated AMS mass spectrum. The results are found to be highly sensitive to the mass accommodation coefficient of the evaporating species.

  7. Smartphones as experimental tools to measure acoustical and mechanical properties of vibrating rods

    Science.gov (United States)

    González, Manuel Á.; González, Miguel Á.

    2016-07-01

    Modern smartphones have calculation and sensor capabilities that make them suitable for use as versatile and reliable measurement devices in simple teaching experiments. In this work a smartphone is used, together with low cost materials, in an experiment to measure the frequencies emitted by vibrating rods of different materials, shapes and lengths. The results obtained with the smartphone have been compared with theoretical calculations and the agreement is good. Alternatively, physics students can perform the experiment described here and use their results to determine the dependencies of the obtained frequencies on the rod characteristics. In this way they will also practice research methods that they will probably use in their professional life.

  8. Vibration parameter measurement using the temporal digital hologram sequence and windowed Fourier transform

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    Real time digital recording and numerical reconstruction of a temporal digital hologram sequence have become feasible in recent years.They provide a new measurement method which enjoys the valuable advantages of being full-field,noncontact and high precision.In this paper,a combined method of temporal digital hologram sequence and windowed Fourier transform is proposed to measure the kinematic parameters of random vibration.A series of holograms are recorded by CCD camera and the original phase can be recon...

  9. Study of Ф-OTDR stability for dynamic strain measurement in piezoelectric vibration

    Science.gov (United States)

    Ren, Meiqi; Lu, Ping; Chen, Liang; Bao, Xiaoyi

    2016-06-01

    In a phase-sensitive optical-time domain reflectometry (Φ-OTDR) system, the challenge for dynamic strain measurement lies in large intensity fluctuations from trace to trace. The intensity fluctuation caused by stochastic characteristics of Rayleigh backscattering sets detection limit for the minimum strength of vibration measurement and causes the large measurement uncertainty. Thus, a trace-to-trace correlation coefficient is introduced to quantify intensity fluctuation of Φ-OTDR traces and stability of the sensor system theoretically and experimentally. A novel approach of measuring dynamic strain induced by various driving voltages of lead zirconate titanate (PZT) in Φ-OTDR is also demonstrated. Piezoelectric vibration signals are evaluated through analyzing peak values of fast Fourier transform spectra at the fundamental frequency and high-order harmonics based on Bessel functions. High trace-to-trace correlation coefficients varying from 0.824 to 0.967 among 100 measurements are obtained in experimental results, showing the good stability of our sensor system, as well as small uncertainty of measured peak values.

  10. Selection of instruments used for vibration measurement of fuel bundles in a pressure tube under CANDU reactor operating conditions

    International Nuclear Information System (INIS)

    Vibration characteristics of CANDU fuel bundle and fuel elements is a key parameter considered in the design of a fuel bundle. Out-reactor frequency and temperature sweep tests, under reactor operating conditions, are performed to verify vibration characteristics of CANDU fuel bundles. Several options have been considered in the selection of vibration instrumentation to perform out-reactor frequency and temperature sweep tests. This paper compares the benefits and disadvantages of various vibration instruments and summarizes the rationale behind the selection of instruments used for vibration measurements over a range of temperature and pressure pulsation frequencies. The conclusions are presented from the bench tests performed, which confirm the use of the selected instruments. (author)

  11. Wind turbine blades condition assessment based on vibration measurements and the level of an empirically decomposed feature

    International Nuclear Information System (INIS)

    Highlights: ► We used finite element method to model wind turbine induced vibration characteristics. ► We developed a technique for eliminating wind turbine’s vibration modulation problems. ► We use empirical mode decomposition to decompose the vibration into its fundamental elements. ► We show the area under shaft speed is a good indicator for assessing wind blades condition. ► We validate the technique under different wind turbine speeds and blade (cracks) conditions. - Abstract: Vibration based monitoring techniques are well understood and widely adopted for monitoring the condition of rotating machinery. However, in the case of wind turbines the measured vibration is complex due to the high number of vibration sources and modulation phenomenon. Therefore, extracting condition related information of a specific element e.g. blade condition is very difficult. In the work presented in this paper wind turbine vibration sources are outlined and then a three bladed wind turbine vibration was simulated by building its model in the ANSYS finite element program. Dynamic analysis was performed and the fundamental vibration characteristics were extracted under two healthy blades and one blade with one of four cracks introduced. The cracks were of length (10 mm, 20 mm, 30 mm and 40 mm), all had a consistent 3 mm width and 2 mm depth. The tests were carried out for three rotation speeds; 150, 250 and 360 r/min. The effects of the seeded faults were revealed by using a novel approach called empirically decomposed feature intensity level (EDFIL). The developed EDFIL algorithm is based on decomposing the measured vibration into its fundamental components and then determines the shaft rotational speed amplitude. A real model of the simulated wind turbine was constructed and the simulation outcomes were compared with real-time vibration measurements. The cracks were seeded sequentially in one of the blades and their presence and severity were determined by decomposing

  12. Development, enhancement, and evaluation of aircraft measurement techniques for national ambient air quality standard criteria pollutants

    Science.gov (United States)

    Brent, Lacey Cluff

    The atmospheric contaminants most harmful to human health are designated Criteria Pollutants. To help Maryland attain the national ambient air quality standards (NAAQS) for Criteria Pollutants, and to improve our fundamental understanding of atmospheric chemistry, I conducted aircraft measurements in the Regional Atmospheric Measurement Modeling Prediction Program (RAMMPP). These data are used to evaluate model simulations and satellite observations. I developed techniques for improving airborne observation of two NAAQS pollutants, particulate matter (PM) and nitrogen dioxide (NO2). While structure and composition of organic aerosol are important for understanding PM formation, the molecular speciation of organic ambient aerosol remains largely unknown. The spatial distribution of reactive nitrogen is likewise poorly constrained. To examine water-soluble organic aerosol (WSOA) during an air pollution episode, I designed and implemented a shrouded aerosol inlet system to collect PM onto quartz fiber filters from a Cessna 402 research aircraft. Inlet evaluation conducted during a side-by-side flight with the NASA P3 demonstrated agreement to within 30%. An ion chromatographic mass spectrometric method developed using the NIST Standard Reference Material (SRM) 1649b Urban Dust, as a surrogate material resulted in acidic class separation and resolution of at least 34 organic acids; detection limits approach pg/g concentrations. Analysis of aircraft filter samples resulted in detection of 8 inorganic species and 16 organic acids of which 12 were quantified. Aged, re-circulated metropolitan air showed a greater number of dicarboxylic acids compared to air recently transported from the west. While the NAAQS for NO2 is rarely exceeded, it is a precursor molecule for ozone, America's most recalcitrant pollutant. Using cavity ringdown spectroscopy employing a light emitting diode (LED), I measured vertical profiles of NO2 (surface to 2.5 km) west (upwind) of the Baltimore

  13. Experimental and theoretical vibration analysis by noise measurements of a sodium cooled reactor

    International Nuclear Information System (INIS)

    Studies of mechanical vibrations of primary components and their correlations with pressure and neutron flux at the compact sodium cooled reactor KNK (20 MWe), Karlsruhe, gave substantial information on the movements of the reactor vessel and its internals. The maximum of the power spectral density together with the observed natural frequencies of reactor components were investigated. The most powerful peaks in the spectra were flow-induced stochastic spectra parts as well as two deterministic lines, excited mechanically by the pumps. Some of these maxima could also be observed by correlating them with the noise of pressure and neutron flux. By means of a model the influence of the process dynamics on the power density spectra of the measured variables was checked. The comparison of power spectral densities and coherences of mechanical vibrations of the vessel at different power levels showed natural frequencies down to 25 cps. Phases of cross power spectral densities revealed a combined horizontal and vertical movement of the reactor vessel. The impact of a free falling control rod was successfully used as a mechanical excitation of the system. The measurements showed natural frequencies of various reactor internals (e.g. core support, shock shield). Tests with variable pump speed gave information on global mechanical characteristics of the reactor system. The use of Donnell's equation for the inner and outer reactor vessel and the shock shield showed good agreement between theoretical and measured natural frequencies and explained the complex structure of the spectra. The employed measurement principles are being investigated with regard to their application for a vibration surveillance system

  14. Design of A Vibration and Stress Measurement System for an Advanced Power Reactor 1400 Reactor Vessel Internals Comprehensive Vibration Assessment Program

    International Nuclear Information System (INIS)

    In accordance with the US Nuclear Regulatory Commission (US NRC), Regulatory Guide 1.20, the reactor vessel internals comprehensive vibration assessment program (RVI CVAP) has been developed for an Advanced Power Reactor 1400 (APR1400). The purpose of the RVI CVAP is to verify the structural integrity of the reactor internals to flow-induced loads prior to commercial operation. The APR1400 RVI CVAP consists of four programs (analysis, measurement, inspection, and assessment). Thoughtful preparation is essential to the measurement program, because data acquisition must be performed only once. The optimized design of a vibration and stress measurement system for the RVI CVAP is essential to verify the integrity of the APR1400 RVI. We successfully designed a vibration and stress measurement system for the APR1400 RVI CVAP based on the design materials, the hydraulic and structural analysis results, and performance tests of transducers in an extreme environment. The measurement system designed in this paper will be utilized for the APR1400 RVI CVAP as part of the first construction project in Korea

  15. Somatosensory Nerve Function, Measured by Vibration Thresholds in Asymptomatic Tennis Players: A Pilot Study

    Directory of Open Access Journals (Sweden)

    Sarah Harrisson

    2015-06-01

    Full Text Available Tennis players are vulnerable to injury in their upper limbs due to the repetitive exposure to racket vibrations and torsional forces during play, leading to musculoskeletal adaptations in the dominant arm including some evidence of changes in nerve function (Colak et al., 2004. Vibration is a sensitive technique for diagnosing mild pathology in clinically asymptomatic participant groups. It has been used in participants with various musculoskeletal disorders (Laursen et al., 2006 (Tucker et al., 2007 showing widespread and bilateral increases in vibration threshold. Tests of somatosensory function by vibration will be abnormal prior to changes in nerve conduction velocity. Thus vibration testing in a sub-clinical group of participants may a more sensitive measure of nerve function compared to nerve conduction by electrodiagnostic testing. The aim of this pilot study was to conduct an exploratory investigation to establish whether tennis players have a reduction in their somatosensory nerve function compared to non- tennis playing controls. It also set out to compare the somatosensory nerve function of the dominant compared to the non-dominant upper limb in tennis players. Healthy tennis players (males, n = 8, females, n = 2, mean age 22 years and control non- tennis playing volunteers (males, n = 6, females, n = 4, mean age 22 years were recruited on an opportunistic basis from a tennis centre in London UK. Participants were excluded if they had any history of neurological impairment, serious injury or fracture or any arthritic condition affecting the upper limbs, cervical or thoracic spine. Control participants were excluded if it was deemed that they played a sport where there was exposure to repetitive use of the upper body. Ethical approval was obtained from the University College London Ethics Committee and all participants gave written informed consent. A preliminary clinical examination was carried out on all participants followed by

  16. Annual report of the ambient air quality measurements in Austria 2000

    International Nuclear Information System (INIS)

    This report presents the result of the ambient air quality measurements conducted according to the air quality act (Austrian Federal Law Gazette I 115/97) in Austria in 2000. This act defines ambient air quality limit values for sulphur dioxide, nitrogen dioxide, total suspended particulates (TSP), carbon monoxide, benzene, lead in air, deposition (total mass including lead and cadmium) and a target value for ozone. The report also comprises results of explorative measurements of PM10 and PM2,5. Only one exceedance of the limit value for sulphur dioxide (0,20 mg/m3 as half hour mean value, not to be exceeded more than three times a day; 0,50 mg/m3 as half hour mean value) was observed. The exceedance was caused by air pollution transport from Slovenia. The limit values for nitrogen dioxide and total suspended particulates were exceeded quite frequently in 2000. For nitrogen dioxide, mainly traffic stations were affected. Exceedances of the limit value (0,20 mg/m3 as half hour mean value) were observed both during winter episodes with unfavourable conditions for dispersion, as well as in spring/summer at a heavily frequented road during episodes with high ozone levels, causing rapid oxidation of NO to NO2. Exceedances of the limit value for total suspended particulates (0,15 mg/m3 as daily mean value) were predominately recorded in urban areas in the vicinity of heavily frequented streets, especially in southern alpine basins and valleys with unfavourable dispersion conditions. The highest pollution was recorded at a heavily frequented crossroad in Graz. For carbon monoxide (eight hour mean value of 10 mg/m3), benzene ( 10 μg/m3 as annual mean value) and lead (1 μg/m3, as annual mean value), no exceedances were recorded. The pollution levels of sulphur dioxide and carbon monoxide show a strong decrease during the last decade, whereas for nitrogen dioxide and particulate matter no clear trend can be identified. The target value of ozone is exceeded at all of the

  17. Vibration measurement-based simple technique for damage detection of truss bridges: A case study

    Directory of Open Access Journals (Sweden)

    Sudath C. Siriwardane

    2015-10-01

    Full Text Available The bridges experience increasing traffic volume and weight, deteriorating of components and large number of stress cycles. Therefore, assessment of the current condition of steel railway bridges becomes necessary. Most of the commonly available approaches for structural health monitoring are based on visual inspection and non-destructive testing methods. The visual inspection is unreliable as those depend on uncertainty behind inspectors and their experience. Also, the non-destructive testing methods are found to be expensive. Therefore, recent researches have noticed that dynamic modal parameters or vibration measurement-based structural health monitoring methods are economical and may also provide more realistic predictions to damage state of civil infrastructure. Therefore this paper proposes a simple technique to locate the damage region of railway truss bridges based on measured modal parameters. The technique is discussed with a case study. Initially paper describes the details of considered railway bridge. Then observations of visual inspection, material testing and in situ load testing are discussed under separate sections. Development of validated finite element model of the considered bridge is comprehensively discussed. Hence, variations of modal parameters versus position of the damage are plotted. These plots are considered as the main reference for locating the damage of the railway bridge in future periodical inspection by comparing the measured corresponding modal parameters. Finally the procedure of periodical vibration measurement and damage locating technique are clearly illustrated.

  18. Study on viscosity measurement using fiber Bragg grating micro-vibration

    International Nuclear Information System (INIS)

    It is now ascertained that traditional electric sensors are vulnerable to electromagnetic interference when measuring viscosity. Here, we propose a new viscosity-sensitive structure based on the fiber Bragg grating (FBG) sensing principle and a micro-vibration measurement method. The symmetric micro-vibration motivation method is also described, and a mathematical model for compensational voltage and fluid viscosity is established. The probe amplitude, which is produced by reciprocating stimulation, is accessible by means of an FBG sensor mounted on an equal-strength beam. Viscosity can be therefore calculated using a demodulation technique based on linear edge filtering with long period grating. After performing a group of verifying tests, the sensor has been subsequently calibrated with a series of standard fluids to determine uncertain parameters in the mathematical model. The results of the experiment show that the relative measurement error was less than 2% when the viscosity ranged from 200 to 500 mPa s. The proposed architecture utilizes the characteristics of anti-interference, fast response speed, high resolution and compact structure of FBG, thereby offering a novel modality to achieve an online viscosity measurement. (paper)

  19. Experimental and theoretical vibration analysis by noise measurements of a sodium cooled reactor

    International Nuclear Information System (INIS)

    Studies of mechanical vibrations of primary components and their correlations with pressure and neutron flux at the compact sodium cooled reactor KNK (20 MWe), Karlsruhe, gave substantial information of the movement of the reactor vessel and its internals. Displacement measurements and noise measurements of pressure and neutron flux were performed in the power range of 27%-100%. The maximum of the power spectral densities together with the observed natural frequencies of reactor components were investigated. By calculating the power spectral densities with different filter bandwidths deterministic and stochastic parts of the spectra were separated. The most powerful peaks in the spectra were flow-induced stochastic spectra parts as well as two deterministic lines, excited mechanically by the pumps. Some of these maxima could also be observed by correlating them with the noise of pressure and neutron flux. By means of a model the influence of the process dynamics on the power density spectra of the measured variables was checked. The comparison of power spectral densities and coherences of mechanical vibrations of the vessel at different power levels showed natural frequencies down to 25 cps. Phases of cross power spectral densities revealed a combined horizontal and vertical movement of the reactor vessel. The impact of a free falling control rod was successfully used as a mechanical excitation of the system. The measurements showed natural frequencies of various reactor internals (e.g. core support, shock shield). Tests with variable pump speed gave information on global mechanical characteristics of the reactor system. (Auth.)

  20. Measuring Very Low Precipitation Events Using a Vibrating Wire All-Weather Precipitation Gauge

    Science.gov (United States)

    Duchon, C. E.

    2005-12-01

    Standard U.S. tipping-bucket precipitation gauges measure event amounts that equal or exceed 0.01 inch (0.254 mm). However, very low precipitation events, defined to be accumulations less than 0.01 inch (0.254 mm), are as much a part of the climate record of precipitation as are event totals that exceed this amount. They indicate the presence of clouds and thus impact the surface energy budget. An increase or decrease in their frequency of occurrence over long periods of time may reflect a changing climate of precipitation. While traditional tipping-bucket gauges cannot record very low precipitation events, the application of vibrating wire technology to the measurement of precipitation can. Very low precipitation events comprising one-minute accumulations will be described as measured by a Geonor T-200B vibrating wire gauge, the primary gauge used in the U.S. Climate Reference Network. Comparisons will be made with a co-located 2-dimensional video disdrometer and a nearby tipping-bucket gauge. Sources of differences among these three independent measurement systems also will be discussed. Faithful numerical weather prediction and climate models need to account for very low precipitation events.

  1. Monitoring method for an ambient Gamma exposure rate and its measurement analysis

    International Nuclear Information System (INIS)

    Daily and seasonal variations of the ambient gamma ray exposure rates were measured by using a pressurized ion chamber from January 2003 to December 2005 in the Cheongju Regional Radiation Monitoring Post and the patterns of the distributions were studied. The annual average of the daily variation of the exposure rate was ∼0.17 μR/h. The exposure rate was found to be maximum during 8:00 am to 9:00 am and minimum during 8:00 pm to 10:00 pm. For the annual data, the exposure rate was the minimum during the month of February. The exposure rate increased from February to mid-October (except during the period from May to July with no change) and decreased from October to February. The seasonal variation was found to be about 1 μR/h. Most of the measured values (96%) of the exposure rates fell under the normal distribution with a deviation of less than 4.8% and the remaining 4% had large fluctuations caused mainly by the rainfalls

  2. Annual report on the ambient air quality measurement in Austria 2004

    International Nuclear Information System (INIS)

    A summary of the ambient air quality situation (measurements) conducted according to the Air Quality Act and the Ozone Act in Austria during 2004 is presented. The situation was assessed mainly in relation to Austrian limit and target values of sulfur dioxide, nitrogen oxides, particulate matter (this is measured using two different indicators: total suspended particulates (TSP) and PM10), carbon monoxide, benzene and lead. The PM10 limit value - 35 days with average concentrations above 50 μg/m3 - was exceeded at 27 sites. The highest exceedances were measured at traffic related sites in large cities, in particular the city of Graz, in Vienna, at industrial sites (e.g. Linz). Main sources for primary particulate matter are road traffic, domestic heating (in particular wood burning), industrial emissions, construction activities and off-road sources. For nitrogen dioxide, the short term limit value was exceeded at few traffic related sites, mainly - but not only - in larger towns. The limit value for the protection of vegetation of 30 μg/m3 NOx was exceeded at one site in Tyrol (Kramsach). Limit values for sulfur dioxide were exceeded at three sites. Neither the limit values for carbon monoxide, lead and benzene nor the alert thresholds for nitrogen dioxide or sulfur dioxide were exceeded in this year. Deposition of total particulates limit value was exceeded at a few sites, lead and cadmium in two industrial sites. Low ozone levels were measured at most monitoring sites, the information threshold of 180 μg/m3 ozone as one hour mean was exceeded at 21 sites on all together 9 days and the alert threshold of 240 μg/m3 as one hour mean was not exceeded. 45 figs., 57 tabs. (nevyjel)

  3. Measurement of the ambient organic aerosol volatility distribution: application during the Finokalia Aerosol Measurement Experiment (FAME-2008

    Directory of Open Access Journals (Sweden)

    B. H. Lee

    2010-12-01

    Full Text Available A variable residence time thermodenuder (TD was combined with an Aerodyne Aerosol Mass Spectrometer (AMS and a Scanning Mobility Particle Sizer (SMPS to measure the volatility distribution of aged organic aerosol in the Eastern Mediterranean during the Finokalia Aerosol Measurement Experiment in May of 2008 (FAME-2008. A new method for the quantification of the organic aerosol volatility distribution was developed combining measurements of all three instruments together with an aerosol dynamics model.

    Challenges in the interpretation of ambient thermodenuder-AMS measurements include the potential resistances to mass transfer during particle evaporation, the effects of particle size on the evaporated mass fraction, the changes in the AMS collection efficiency and particle density as the particles evaporate partially in the TD, and finally potential losses inside the TD. Our proposed measurement and data analysis method accounts for all of these problems combining the AMS and SMPS measurements.

    The AMS collection efficiency of the aerosol that passed through the TD was found to be approximately 10% lower than the collection efficiency of the aerosol that passed through the bypass. The organic aerosol measured at Finokalia is approximately 2 or more orders of magnitude less volatile than fresh laboratory-generated monoterpene (α-pinene, β-pinene and limonene under low NOx conditions secondary organic aerosol. This low volatility is consistent with its highly oxygenated AMS mass spectrum. The results are found to be highly sensitive to the mass accommodation coefficient of the evaporating species. This analysis is based on the assumption that there were no significant reactions taking place inside the thermodenuder.

  4. Measurement of the ambient organic aerosol volatility distribution: application during the Finokalia Aerosol Measurement Experiment (FAME-2008)

    Science.gov (United States)

    Lee, B. H.; Kostenidou, E.; Hildebrandt, L.; Riipinen, I.; Engelhart, G. J.; Mohr, C.; Decarlo, P. F.; Mihalopoulos, N.; Prevot, A. S. H.; Baltensperger, U.; Pandis, S. N.

    2010-12-01

    A variable residence time thermodenuder (TD) was combined with an Aerodyne Aerosol Mass Spectrometer (AMS) and a Scanning Mobility Particle Sizer (SMPS) to measure the volatility distribution of aged organic aerosol in the Eastern Mediterranean during the Finokalia Aerosol Measurement Experiment in May of 2008 (FAME-2008). A new method for the quantification of the organic aerosol volatility distribution was developed combining measurements of all three instruments together with an aerosol dynamics model. Challenges in the interpretation of ambient thermodenuder-AMS measurements include the potential resistances to mass transfer during particle evaporation, the effects of particle size on the evaporated mass fraction, the changes in the AMS collection efficiency and particle density as the particles evaporate partially in the TD, and finally potential losses inside the TD. Our proposed measurement and data analysis method accounts for all of these problems combining the AMS and SMPS measurements. The AMS collection efficiency of the aerosol that passed through the TD was found to be approximately 10% lower than the collection efficiency of the aerosol that passed through the bypass. The organic aerosol measured at Finokalia is approximately 2 or more orders of magnitude less volatile than fresh laboratory-generated monoterpene (α-pinene, β-pinene and limonene under low NOx conditions) secondary organic aerosol. This low volatility is consistent with its highly oxygenated AMS mass spectrum. The results are found to be highly sensitive to the mass accommodation coefficient of the evaporating species. This analysis is based on the assumption that there were no significant reactions taking place inside the thermodenuder.

  5. Estimation of the in-plane vibrations of a rotating spindle, using out-of-plane laser vibrometry measurements

    Science.gov (United States)

    Tatar, Kourosh; Gren, Per

    2016-05-01

    A method for estimating the in-plane vibrations of a rotating spindle using out-of-plane laser vibrometry measurements is described. This method enables the possibility to obtain the two orthogonal radial vibration components of a rotating spindle. The method uses the fact that the laser vibrometer signal is a total surface velocity of the measurement point in the laser direction. Measurements are conducted on a rotating milling machine spindle. The spindle is excited in a controlled manner by an active magnetic bearing and the response is measured by laser vibrometer in one of the two orthogonal directions and inductive displacement sensors in two orthogonal directions simultaneously. The work shows how the laser vibrometry crosstalk can be used for resolving the in-plane vibration component, that is the vibrations in the laser vibrometer cross direction. The result is compared to independent measurement signals from the displacement sensors. The measurement method can be used for vibration measurements on rotating parts, for example, where there is lack of space for orthogonal measurements.

  6. Influence of ambient meteorology on the accuracy of radiation measurements: insights from field and laboratory experiments

    Science.gov (United States)

    Oswald, Sandro M.; Pietsch, Helga; Baumgartner, Dietmar J.; Rieder, Harald E.

    2016-04-01

    A precise knowledge of the surface energy budget, which includes the solar and terrestrial radiation fluxes, is needed to accurately characterize the global energy balance which is largely determining Earth's climate. To this aim national and global monitoring networks for surface radiative fluxes have been established in recent decades. The most prominent among these networks is the so-called Baseline Surface Radiation Network (BSRN) operating under the auspices of the World Climate Research Programme (WCRP) (Ohmura et al., 1998). National monitoring networks such as the Austrian RADiation Monitoring Network (ARAD), which has been established in 2010 by a consortium of the Central Agency of Meteorology and Geodynamics (ZAMG), the University of Graz, the University of Innsbruck, and the University of Natural Resources and Applied Sciences, Vienna (BOKU), orient themselves on BSRN standards (McArthur, 2005). ARAD comprises to date five sites (Wien Hohe Warte, Graz/University, Innsbruck/University, Kanzelhöhe Observatory and Sonnblick (which is also a BSRN site)) and aims to provide long-term monitoring of radiation budget components at highest accuracy and to capture the spatial patterns of radiation climate in Austria (Olefs et al., 2015). Given the accuracy requirement for the local monitoring of radiative fluxes instrument offsets, triggered by meteorological factors and/or instrumentation, pose a major challenge in radiation monitoring. Within this study we investigate effects of ambient meteorology on the accuracy of radiation measurements performed with pyranometers contained in various heating/ventilation systems (HV-systems), all of which used in regular operation within the ARAD network. We focus particularly on instrument offsets observed following precipitation events. To quantify pyranometer responses to precipitation we performed a series of controlled laboratory experiments as well as targeted field campaigns in 2015 and 2016. Our results indicate

  7. Comparison of ambient aerosol extinction coefficients obtained from in-situ, MAX-DOAS and LIDAR measurements at Cabauw

    NARCIS (Netherlands)

    Zieger, P.; Weingartner, E.; Henzing, J.; Moerman, M.; Leeuw, G. de; Mikkilä, J.; Ehn, M.; Petäjä, T.; Clémer, K.; Roozendael, M. van; Yilmaz, S.; Frieß, U.; Irie, H.; Wagner, T.; Shaiganfar, R.; Beirle, S.; Apituley, A.; Wilson, K.; Baltensperger, U.

    2011-01-01

    In the field, aerosol in-situ measurements are often performed under dry conditions (relative humidity RH<30-40%). Since ambient aerosol particles experience hygroscopic growth at enhanced RH, their microphysical and optical properties especially the aerosol light scattering are also strongly depend

  8. Fiber-optic sensor family for the measurement of temperature, vibration, and pressure

    International Nuclear Information System (INIS)

    A family of fiberoptic sensors for measuring temperature, vibration and pressure is described with respect to measurement principle, sensor design and optical construction. Non-coherent optical luminescence phenomena are used as information carriers for the measuring parameters. The sensors contain luminescent materials (gallium arsenide or neodymium-doped glass) and have a mechanical design that is determined by the specific application. The optical design of the system is based on beam splitters with interference filters and other micro-components. Experimental results of present designs are described and the development potential of the sensors is discussed. Finally, an overview of present application areas is given together with results from recent field experiments and reference installations in progress at present. (orig.)

  9. Measurement of ambient aerosols in northern Mexico City by single particle mass spectrometry

    Directory of Open Access Journals (Sweden)

    R. C. Moffet

    2007-05-01

    Full Text Available Continuous ambient measurements with aerosol time-of-flight mass spectrometry (ATOFMS were carried out in an industrial/residential section in the northern part of Mexico City as part of the Mexico City Metropolitan Area – 2006 campaign (MCMA-2006 between 7–27 March, 2006. Biomass and organic carbon (OC particle types were found to dominate the accumulation mode both day and night. The concentrations of both organic carbon and biomass particles were roughly equal early in the morning, but biomass became the largest contributor to the accumulation mode mass from the late morning until early evening. The diurnal pattern can be attributed to aging and/or a change in meteorology. Fresh elemental carbon (EC particles were observed during rush hour. The majority of the EC particles were mixed with nitrate, sulfate, organic carbon and potassium. Submicron particles from industrial sources in the northeast were composed of an internal mixture of Pb, Zn, EC and Cl and peaked early in the morning. A unique nitrogen-containing organic (NOC particle type was observed, and is hypothesized to be from industrial emissions based on the temporal profile and back trajectory analysis. This study provides unique insights into the real-time changes in single particle mixing state as a function of size and time for aerosols in Mexico City. These new findings indicate that biomass burning and industrial operations make significant contributions to particles in Mexico City. These sources have received relatively little attention in previous intensive field campaigns.

  10. Water and organic nitrate detection in an AMS. Laboratory characterization and application to ambient measurements

    Energy Technology Data Exchange (ETDEWEB)

    Mensah, Amewu A.

    2011-08-12

    Atmospheric aerosols were studied by three different means. Laboratory experiments determined the relative ionization efficiency of water (RIE{sub H2O}) in an Aerodyne Aerosol Mass Spectrometers (AMS), simulation chamber experiments gave insight to the reaction products of biogenic volatile organic compounds (BVOC) oxidation products, and the findings were applied to two field campaign measurements at Cabauw, NL, in May 2008 and February 2009. Knowing the liquid water content of aerosol particles is vital for the assessment of their climate forcing potential. A value of 2 for RIE{sub H2O} was determined by studying oxalate salts with different amounts of crystal water. BVOCs contribute much more to the global budget of VOCs than anthropogenic ones but oxidation products in terms of secondary organic aerosol often correlate to anthropogenic tracers such as NO{sub x} from fossil fuel burning. In atmospheric simulation chamber experiments, organic nitrates from BVOC-NO{sub 3} oxidation showed higher vapor pressures than pure organic compounds produced in the same reactions. Organic nitrates comprised up to approx. 41 % of the particulate phase. A specific fragmentation ratio of nitrate (NO{sub 2}{sup +}/NO{sup +}) of 0.1 was found by high resolution AMS analysis differing strongly from the value of 0.4 known for the most abundant ambient NO{sub 3} specie (NH{sub 4}NO{sub 3}). Ambient average particulate mass loadings were 9.72 {mu}g/m{sup 3} dominated by organics (40 %) in 2008 and 5.62 {mu}g/m{sup 3} dominated by nitrate (42 %) in 2009. Data comparison to collocated instruments showed good agreement. Positive Matrix Factorization analysis of the particulate organic fraction distinguished semi and low volatile oxygenated organic aerosol (OOA) as well as hydrocarbon like organic aerosol (HOA) in both campaigns. An additional highly oxygenated OA with a mass spectrum very similar to fulvic acid was found in 2008. The average contribution of organic nitrate to the

  11. Simultaneous measurements of global vibrational spectra and dephasing times of molecular vibrational modes by broadband time-resolved coherent anti-Stokes Raman scattering spectrography

    Institute of Scientific and Technical Information of China (English)

    Yin Jun; Yu Ling-Yao; Liu Xing; Wan Hui; Lin Zi-Yang; Niu Han-Ben

    2011-01-01

    In broadband coherent anti-Stokes Raman scattering (CARS) spectroscopy with supercontinuum (SC), the simultaneously detectable spectral coverage is limited by the spectral continuity and the simultaneity of various spectral components of SC in an enough bandwidth. By numerical simulations, the optimal experimental conditions for improving the SC are obtained. The broadband time-resolved CARS spectrography based on the SC with required temporal and spectral distributions is realised. The global molecular vibrational spectrum with well suppressed nonresonant background noise can be obtained in a single measurement. At the same time, the measurements of dephasing times of verious molecular vibrational modes can be conveniently achieved from intensities of a sequence of time-resolved CARS signals. It will be more helpful to provide a complete picture of molecular vibrations, and to exhibit a potential to understand not only both the solvent dynamics and the solute-solvent interactions, but also the mechanisms of chemical reactious in the fields of biology, chemistry and naterial science.

  12. Simultaneous measurements of global vibrational spectra and dephasing times of molecular vibrational modes by broadband time-resolved coherent anti-Stokes Raman scattering spectrography

    International Nuclear Information System (INIS)

    In broadband coherent anti-Stokes Raman scattering (CARS) spectroscopy with supercontinuum (SC), the simultaneously detectable spectral coverage is limited by the spectral continuity and the simultaneity of various spectral components of SC in an enough bandwidth. By numerical simulations, the optimal experimental conditions for improving the SC are obtained. The broadband time-resolved CARS spectrography based on the SC with required temporal and spectral distributions is realised. The global molecular vibrational spectrum with well suppressed nonresonant background noise can be obtained in a single measurement. At the same time, the measurements of dephasing times of various molecular vibrational modes can be conveniently achieved from intensities of a sequence of time-resolved CARS signals. It will be more helpful to provide a complete picture of molecular vibrations, and to exhibit a potential to understand not only both the solvent dynamics and the solute-solvent interactions, but also the mechanisms of chemical reactions in the fields of biology, chemistry and material science. (electromagnetism, optics, acoustics, heat transfer, classical mechanics, and fluid dynamics)

  13. Brachial Artery Responses to Ambient Pollution, Temperature, and Humidity in People with Type 2 Diabetes: A Repeated-Measures Study

    OpenAIRE

    Zanobetti, Antonella; Luttmann-Gibson, Heike; Horton, Edward S.; Cohen, Allison; Coull, Brent A.; Hoffmann, Barbara; Schwartz, Joel D; Mittleman, Murray A.; Li, Yongsheng; Stone, Peter H.; de Souza, Celine; Lamparello, Brooke; Koutrakis, Petros; Gold, Diane R.

    2014-01-01

    Background: Extreme weather and air pollution are associated with increased cardiovascular risk in people with diabetes. Objectives: In a population with diabetes, we conducted a novel assessment of vascular brachial artery responses both to ambient pollution and to weather (temperature and water vapor pressure, a measure of humidity). Methods: Sixty-four 49- to 85-year-old Boston residents with type 2 diabetes completed up to five study visits (279 repeated measures). Brachial artery diamete...

  14. Design of a quasi-zero-stiffness based sensor system for the measurement of absolute vibration displacement of moving platforms

    Science.gov (United States)

    Jing, Xingjian; Wang, Yu; Li, Quankun; Sun, Xiuting

    2016-09-01

    This study presents the analysis and design of a novel sensor system for measuring the absolute vibration displacement of moving platforms based on the concept of quasi-zero-stiffness (QZS). The sensor system is constructed using positive- and negative-stiffness springs, which make it possible to achieve an equivalent QZS and consequently to create a broadband vibration-free point for absolute vibration displacement measurement in moving platforms. Theoretical analysis is conducted for the analysis and design of the influence of structure parameters on system measurement performance. A prototype is designed which can avoid the drawback of instability in existing QZS systems with negative stiffness, and corresponding data-processing software is developed to fulfill time domain measurements. Both the simulation and experimental results verify the effectiveness of this novel sensor system.

  15. An automated fringe counting laser interferometer for low frequency vibration measurements

    Science.gov (United States)

    Payne, B. F.; Federman, Charles

    Low-frequency accelerometers and velocity transducers are widely used to investigate vibrations on structures such as buildings, bridges, aircraft, ships, power plant equipment, and in seismic applications. Previous work at NBS in this area has focused on the development of accurate calibration methods for transducers by optical methods in the frequency range of 2-100 Hz. This paper describes a computer-controlled fringe-counting interferometric system for transducer calibration. The calibration system uses digital signal analysis for accurate low-frequency voltage measurements. The measurement procedures are fully automated, with menu-driven programs using the computer soft keys for controlling the test frequencies and acceleration, setting test parameters, collecting and storing data and producing reports and graphs. An error analysis is given and experimental data are presented for a typical transducer calibrated on this system.

  16. Novel approach for non-invasive glucose sensing using vibrational contrast CD absorption measurements (Conference Presentation)

    Science.gov (United States)

    Yakovlev, Vladislav V.; Tovar, Carlos; Hokr, Brett; Petrov, Georgi I.

    2016-03-01

    Noninvasive glucose sensing is a Holy Grail of diabetes mellitus management. Unfortunately, despite a number of innovative concepts and a long history of continuous instrumental improvements, the problem remains largely unsolved. Here we propose and experimentally demonstrate the first successful implementation of a novel strategy based on vibrational overtone circular dichroism absorption measurements. Such an approach uses a short-wavelength infrared excitation (1000-2000 nm), which takes the advantage of lower light scattering and intrinsic chemical contrast provided by the chemical structure of D-glucose molecule. We model the propagation of circular polarized light in scattering medium using Monte Carlo simulations to show the feasibility of such approach in turbid medium and demonstrate the proof of principle using optical detection. We also investigate the possibility of using ultrasound detection through circular dichroism absorption measurements to achieve simple and sensitive glucose monitoring.

  17. Fault Diagnosis for Rotating Machinery Using Vibration Measurement Deep Statistical Feature Learning

    Directory of Open Access Journals (Sweden)

    Chuan Li

    2016-06-01

    Full Text Available Fault diagnosis is important for the maintenance of rotating machinery. The detection of faults and fault patterns is a challenging part of machinery fault diagnosis. To tackle this problem, a model for deep statistical feature learning from vibration measurements of rotating machinery is presented in this paper. Vibration sensor signals collected from rotating mechanical systems are represented in the time, frequency, and time-frequency domains, each of which is then used to produce a statistical feature set. For learning statistical features, real-value Gaussian-Bernoulli restricted Boltzmann machines (GRBMs are stacked to develop a Gaussian-Bernoulli deep Boltzmann machine (GDBM. The suggested approach is applied as a deep statistical feature learning tool for both gearbox and bearing systems. The fault classification performances in experiments using this approach are 95.17% for the gearbox, and 91.75% for the bearing system. The proposed approach is compared to such standard methods as a support vector machine, GRBM and a combination model. In experiments, the best fault classification rate was detected using the proposed model. The results show that deep learning with statistical feature extraction has an essential improvement potential for diagnosing rotating machinery faults.

  18. Development of stable support stand using cordierite ceramic and its vibration measurement

    International Nuclear Information System (INIS)

    A stable ceramic stand has been developed in order to support the high-precision BPMs: beam position monitors and focusing elements along the undulator line in SCSS X-ray FEL project, which is aiming at generating coherent X-rays in 1 A wavelength before a year of 2010. The ceramic support made by cordierite material that has a very low thermal expansion coefficient of ∼2 x 10-6/0K. This is about ten times lower than that of steel, thus provides higher stability against temperature variation. Additionally, position adjustment screws were removed from supporting structure design, i.e., the ceramic stand will be directly placed on a very flat concrete floor, which is polished by a special grinding machine, and accelerator components will be directly mounted on the top flange of the stand without using level adjustment screws. This is for rigid mechanical structure, and provides lower mechanical vibration amplification and a stable positioning function against transverse forces due to various connections, such as vacuum pipes, electric cables, and cooling water pipes. In this paper, we report development and vibration measurement of the stable ceramic support, and show how stable the stand is as compared with a steel stand. (author)

  19. Fault Diagnosis for Rotating Machinery Using Vibration Measurement Deep Statistical Feature Learning.

    Science.gov (United States)

    Li, Chuan; Sánchez, René-Vinicio; Zurita, Grover; Cerrada, Mariela; Cabrera, Diego

    2016-01-01

    Fault diagnosis is important for the maintenance of rotating machinery. The detection of faults and fault patterns is a challenging part of machinery fault diagnosis. To tackle this problem, a model for deep statistical feature learning from vibration measurements of rotating machinery is presented in this paper. Vibration sensor signals collected from rotating mechanical systems are represented in the time, frequency, and time-frequency domains, each of which is then used to produce a statistical feature set. For learning statistical features, real-value Gaussian-Bernoulli restricted Boltzmann machines (GRBMs) are stacked to develop a Gaussian-Bernoulli deep Boltzmann machine (GDBM). The suggested approach is applied as a deep statistical feature learning tool for both gearbox and bearing systems. The fault classification performances in experiments using this approach are 95.17% for the gearbox, and 91.75% for the bearing system. The proposed approach is compared to such standard methods as a support vector machine, GRBM and a combination model. In experiments, the best fault classification rate was detected using the proposed model. The results show that deep learning with statistical feature extraction has an essential improvement potential for diagnosing rotating machinery faults. PMID:27322273

  20. Virtual additive moments measured by a vibrating sample magnetometer on superconducting thin films

    International Nuclear Information System (INIS)

    Virtual additive magnetic moment was observed on a series of YBaCuO thin films in an external field perpendicular to the film plane: magnetic hysteresis loops measured by a PAR 155 vibrating sample magnetometer up to fields of ±2 T were symmetrical at high field sweep rates, whereas at low sweep rates they exhibited a large additive offset of the reversible magnetic moment. This effect increased particularly at high fields and it was especially noticeable at intermediate temperatures, typically between 40 and 65 K. We identified this phenomenon as an artefact originating from vibrations of a sample possessing a high differential susceptibility in a slightly inhomogeneous bias field. This undesirable effect is quite general and it can be generated in any type of VSM with even very slight inhomogeneity of magnetic field. It can however, be found only on laterally large, thin samples with a high differential susceptibility (typically thin films). Experimental results are consistently explained by the proposed model. We present expressions which enable us to estimate this effect from the differential susceptibility of the sample and known inhomogeneity of the bias magnetic field. (author)

  1. Integrating Oil Debris and Vibration Measurements for Intelligent Machine Health Monitoring. Degree awarded by Toledo Univ., May 2002

    Science.gov (United States)

    Dempsey, Paula J.

    2003-01-01

    A diagnostic tool for detecting damage to gears was developed. Two different measurement technologies, oil debris analysis and vibration were integrated into a health monitoring system for detecting surface fatigue pitting damage on gears. This integrated system showed improved detection and decision-making capabilities as compared to using individual measurement technologies. This diagnostic tool was developed and evaluated experimentally by collecting vibration and oil debris data from fatigue tests performed in the NASA Glenn Spur Gear Fatigue Rig. An oil debris sensor and the two vibration algorithms were adapted as the diagnostic tools. An inductance type oil debris sensor was selected for the oil analysis measurement technology. Gear damage data for this type of sensor was limited to data collected in the NASA Glenn test rigs. For this reason, this analysis included development of a parameter for detecting gear pitting damage using this type of sensor. The vibration data was used to calculate two previously available gear vibration diagnostic algorithms. The two vibration algorithms were selected based on their maturity and published success in detecting damage to gears. Oil debris and vibration features were then developed using fuzzy logic analysis techniques, then input into a multi sensor data fusion process. Results show combining the vibration and oil debris measurement technologies improves the detection of pitting damage on spur gears. As a result of this research, this new diagnostic tool has significantly improved detection of gear damage in the NASA Glenn Spur Gear Fatigue Rigs. This research also resulted in several other findings that will improve the development of future health monitoring systems. Oil debris analysis was found to be more reliable than vibration analysis for detecting pitting fatigue failure of gears and is capable of indicating damage progression. Also, some vibration algorithms are as sensitive to operational effects as they

  2. Vibration control of a flexible clamped-clamped plate based on an improved FULMS algorithm and laser displacement measurement

    Science.gov (United States)

    Xie, Lingbo; Qiu, Zhi-cheng; Zhang, Xian-min

    2016-06-01

    This paper presents a novel active resonant vibration control experiment of a flexible clamped-clamped plate using an improved filtered-U least mean square (FULMS) algorithm and laser displacement measurement. Different from the widely used PZT sensors or acceleration transducers, the vibration of the flexible clamped-clamped plate is measured by a non-contact laser displacement measurement sensor with higher measurement accuracy and without additional load to the plate. The conventional FULMS algorithm often uses fixed step size and needs reference signal related to the external disturbance signal. However, the fixed step size method cannot obtain a fast convergence speed and it will result in a low residual error. Thus, a variable step size method is investigated. In addition, it is difficult to extract reference signal related to the vibration source directly in the practical application. Therefore, it is practically useful that a reference signal is constructed by both the controller parameters and the vibration residual signal. The experimental results demonstrate that the improved FULMS algorithm has better vibration control effect than the proportional derivative (PD) feedback control algorithm and the fixed step-size control algorithm.

  3. Handbook Of Noise And Vibration

    International Nuclear Information System (INIS)

    This book is about noise and vibration. The first chapter has explanations of noise such as basic of sound, influence of noise, assessment of noise, measurement of prevention of noise and technology, case of noise measurement and soundproof. The second chapter describes vibration with outline, theory of vibration, interpretation of vibration, measurement for reduction of vibration, case of design of protection against vibration. It deals with related regulation and method of measurement.

  4. Measurements on very small single crystals of NdFeB using a vibrating reed magnetometer

    International Nuclear Information System (INIS)

    Nd2Fe14B single crystals with magnetic moments ranging from 1.6 x 10-8 Acm2 to 9.5 x 10-7 Acm2 are measured using the ultra high sensitivity vibrating reed magnetometer. The hysteresis loops are compared to those of BaFe12O19 single crystals. It turns out that the magnetization reversal of the Nd2Fe14B samples is similar to that of BaFe12O19 single crystals if the ferrite samples are considerably bigger in size. This does not hold for bigger Nd2Fe14B particles where stronger domain wall pinning is observed. For very small grains of Nd2Fe14B there is still evidence of domain wall processes while for BaFe12O19 grains of the same size true single domain behaviour can be observed

  5. Harvestable vibrational energy from an avian source: theoretical predictions vs. measured values

    Science.gov (United States)

    Shafer, Michael W.; MacCurdy, Robert; Garcia, Ephrahim; Winkler, David

    2012-04-01

    For many reasons, it would be beneficial to have the capability of powering a wildlife tag over the course of multiple migratory seasons. Such an energy harvesting system would allow for more data collection and eliminate the need to replace depleted batteries. In this work, we investigate energy harvesting on birds and focus on vibrational energy harvesting. We review a method of predicting the amount of power that can be safely harvested from the birds such that the effect on their longterm survivability is not compromised. After showing that the safely harvestable power is significant in comparison to the circuits used in avian tags, we present testing results for the flight accelerations of two species of birds. Using these measured values, we then design harvesters that matched the flight acceleration frequency and are sufficiently low mass to be carried by the birds.

  6. Vortex-induced vibration of a harbor-vibrissa-shaped cylinder: Experimental measurements.

    Science.gov (United States)

    Liu, Yingzheng; Wang, Shaofei

    2015-11-01

    Influence of the unique surface variation of the harbor seal vibrissa on its vortex-induced vibration was extensively investigated in a low-speed wind tunnel. Toward this end, a scaled-up model of the harbor-vibrissa-shaped cylinder was employed for measurement, while a circular cylinder sharing the same hydraulic diameter, mass ratio and nature frequency was used as baseline case. Two configurations with and without the approaching Karman-vortex street were respectively tested for both cylinders at various free stream flow speeds. Here, the Karman-vortex street was generated by placing a circular cylinder far up stream. A laser displacement sensor having a high time-spatial resolution was used to capture the cross-stream displacement of the cylinders. The fluctuating pressure distribution on the surface and the wake flow pattern were captured by microphone array and the planar Particle Image Velocimetry, respectively. National Natural Science Foundation of China (grant nos. 51176108, and 11372189).

  7. Fast-adaptive fiber-optic sensor for ultra-small vibration and deformation measurement

    International Nuclear Information System (INIS)

    Adaptive fiber-optic interferometer measuring system based on a dynamic hologram recorded in photorefractive CdTe crystal without applying an external electric field is developed. Vectorial mixing of two waves with different polarizations in the anisotropic diffraction geometry allows for the realization of linear regime of phase demodulation at the diffusion hologram. High sensitivity of the interferometer is achieved due to recording of the hologram in reflection geometry at high spatial frequencies in a crystal with sufficient concentration of photorefractive centers. The sensitivity obtained makes possible a broadband detection of ultra-small vibrations with amplitude of less then 0.1 nm. High cut-off frequency of the interferometer achieved using low-power light sources due to fast response of CdTe crystal allows one to eliminate temperature fluctuations and other industrial noises

  8. A vibrating reed apparatus to measure the natural frequency of multilayered thin films

    Science.gov (United States)

    Gamboa, F.; López, A.; Avilés, F.; Corona, J. E.; Oliva, A. I.

    2016-04-01

    An apparatus for measuring the natural frequency of sub-micrometric layered films in cantilever beam configuration is presented. The instrument comprises a specially designed test rig with a sample holder, an electronic excitation source, a vibration sensor and an automated software for the excitation and data recollection. The beam is excited by means of an air pulse and the oscillation amplitude of its free end is measured through a laser diode-photosensor arrangement. The instrument provides a very low uncertainty (˜1 mHz, for frequencies of the order of tens Hz) for repeated sequential tests and the major source of uncertainty (˜0.2 Hz, corresponding to a coefficient of variation of 0.18%) arises from the difficulty of placing the sample in an exactly identical location upon clamping. This high sensitivity renders the capability of measuring very small frequency shifts upon deposition of sub-micrometric films over thicker substrates. In order to assess the reliability of the apparatus, cantilever beams of 125 μm thick neat Kapton (substrate) and thin layered films of Au/Kapton and Al/Au/Kapton of 200-250 nm film thickness were fabricated and their natural frequency and damping factor were measured. Calculations of the natural frequency of such beams by finite element analysis further support the accuracy of the experimental measurements.

  9. Vortex phase and Jc from magnetisation measurement of MgB2 prepared at ambient pressure

    International Nuclear Information System (INIS)

    Magnetisation data of polycrystalline MgB2 samples prepared at ambient pressure are presented. Data were analyzed with respect to the critical current density and irreversible magnetic field. Vortex phase was ascertained to be vortex glass separated by vortex liquid. Thermo-magnetic instabilities were observed at low temperatures. Jc-B relation revealed weak pinning scenario of the flux lines. (author)

  10. Application of Ambient Analysis Techniques for the Estimation of Electromechanical Oscillations from Measured PMU Data in Four Different Power Systems

    DEFF Research Database (Denmark)

    Vanfretti, Luigi; Dosiek, Luke; Pierre, John W.;

    2011-01-01

    methodologies have been included in off-line analysis software, and are now being incorporated into software tools used in control rooms for monitoring the near real-time behavior of power system dynamics. In this paper we illustrate the practical application of some ambient analysis methods for......The application of advanced signal processing techniques to power system measurement data for the estimation of dynamic properties has been a research subject for over two decades. Several techniques have been applied to transient (or ringdown) data, ambient data, and to probing data. Some of these...... electromechanicalmode estimation in different power systems. We apply these techniques to phasor measurement unit (PMU) data from stored archives of several hours originating from the US Eastern Interconnection (EI), the Western Electricity Coordinating Council (WECC), the Nordic Power System, and time...

  11. On dithiothreitol (DTT) as a measure of oxidative potential for ambient particles: evidence for the importance of soluble transition metals

    OpenAIRE

    J. G. Charrier; Anastasio, C.

    2012-01-01

    The rate of consumption of dithiothreitol (DTT) is increasingly used to measure the oxidative potential of particulate matter (PM), which has been linked to the adverse health effects of PM. While several quinones are known to be very reactive in the DTT assay, it is unclear what other chemical species might contribute to the loss of DTT in PM extracts. To address this question, we quantify the rate of DTT loss from individual redox-active species that are common in ambient particulat...

  12. Measurement of the neutron spectrum and ambient neutron dose rate equivalent from the small 252Cf source at 1 meter

    International Nuclear Information System (INIS)

    NASA Langley Research Center requested a measurement of the neutron spectral distribution and fluence from the 252Cf source (model NS-120, LLNL serial # 7001677, referred as the SMALL Cf source) and determination of the ambient neutron dose rate equivalent and kerma at 100 cm for the Radiation Budget Instrument Experiment (Rad-X). The dosimetric quantities should be based on the neutron spectrum and the current neutron-to-dose conversion coefficients.

  13. Experimental measurement of energy density in a vibrating plate and comparison with energy finite element analysis

    Science.gov (United States)

    Navazi, H. M.; Nokhbatolfoghahaei, A.; Ghobad, Y.; Haddadpour, H.

    2016-08-01

    In this paper, a new method and formulation is presented for experimental measurement of energy density of high frequency vibrations of a plate. By use of the new proposed method and eight accelerometers, both kinetic and potential energy densities are measured. Also, a computer program is developed based on energy finite element method to evaluate the proposed method. For several points, the results of the developed experimental formulation are compared with those of the energy finite element analysis results. It is observed that, there is a good agreement between experimental results and analyses. Finally, another test setup with reduced accelerometer spacing was prepared and based on the comparison between kinetic and potential results, it is concluded that, the kinetic and potential counterparts of the energy density are equal in high frequency bands. Based on this conclusion, the measurement procedure was upgraded to an efficient and very simple one for high frequency ranges. According to the new test procedure, another experimental measurement was performed and the results had a good agreement with the EFEA results.

  14. Measurement Model and Precision Analysis of Accelerometers for Maglev Vibration Isolation Platforms

    Directory of Open Access Journals (Sweden)

    Qianqian Wu

    2015-08-01

    Full Text Available High precision measurement of acceleration levels is required to allow active control for vibration isolation platforms. It is necessary to propose an accelerometer configuration measurement model that yields such a high measuring precision. In this paper, an accelerometer configuration to improve measurement accuracy is proposed. The corresponding calculation formulas of the angular acceleration were derived through theoretical analysis. A method is presented to minimize angular acceleration noise based on analysis of the root mean square noise of the angular acceleration. Moreover, the influence of installation position errors and accelerometer orientation errors on the calculation precision of the angular acceleration is studied. Comparisons of the output differences between the proposed configuration and the previous planar triangle configuration under the same installation errors are conducted by simulation. The simulation results show that installation errors have a relatively small impact on the calculation accuracy of the proposed configuration. To further verify the high calculation precision of the proposed configuration, experiments are carried out for both the proposed configuration and the planar triangle configuration. On the basis of the results of simulations and experiments, it can be concluded that the proposed configuration has higher angular acceleration calculation precision and can be applied to different platforms.

  15. Wavelet analysis on vibration modal frequency measurement at a low level of strain of the turbine blade using FBG sensors

    International Nuclear Information System (INIS)

    Vibration modal frequency measurement of a turbine blade was investigated by using fiber Bragg grating (FBG) sensors for their adaptation for a low level of strain at high frequency. However, the signal-to-noise ratio was so low that it was very difficult to identify dominant modal frequency from a raw signal acquired. An attempt was made to solve this problem. First, a bi-linear transform elliptic filter with pass-band and stop-band was proposed to remove electromagnetic interference noise. Second, discrete stationary wavelet transform with a soft threshold was utilized to de-noise the high-frequency part. Third, wavelet packet transform was exploited to decompose the time signal and to obtain the power spectrum and identification of dominant modal frequency. Experimental and analytic results demonstrated that four stages of dominant modal frequencies of the turbine blade without any constraint condition (free vibration) and three stages of dominant modal frequencies with a constraint condition (A-type vibration) were obtained, respectively. To testify to the validity of analytic results, a professional computer random signal and vibration analysis system (CRAS) was used to measure modal frequency. The results illustrated that modal frequencies obtained by the CRAS platform yielded close agreement with those based on FBG sensors. Obviously, wavelet analysis is successfully employed to decode vibration modal frequency from a raw signal of FBG sensors

  16. Measurement of ambient aerosols in northern Mexico City by single particle mass spectrometry

    Directory of Open Access Journals (Sweden)

    R. C. Moffet

    2008-08-01

    Full Text Available Continuous ambient measurements with aerosol time-of-flight mass spectrometry (ATOFMS were made in an industrial/residential section in the northern part of Mexico City as part of the Mexico City Metropolitan Area-2006 campaign (MCMA-2006. Results are presented for the period of 15–27 March 2006. The submicron size mode contained both fresh and aged biomass burning, aged organic carbon (OC mixed with nitrate and sulfate, elemental carbon (EC, nitrogen-organic carbon, industrial metal, and inorganic NaK inorganic particles. Overall, biomass burning and aged OC particle types comprised 40% and 31%, respectively, of the submicron mode. In contrast, the supermicron mode was dominated by inorganic NaK particle types (42% which represented a mixture of dry lake bed dust and industrial NaK emissions mixed with soot. Additionally, aluminosilicate dust, transition metals, OC, and biomass burning contributed to the supermicron particles. Early morning periods (2–6 a.m. showed high fractions of inorganic particles from industrial sources in the northeast, composed of internal mixtures of Pb, Zn, EC and Cl, representing up to 73% of the particles in the 0.2–3μm size range. A unique nitrogen-containing organic carbon (NOC particle type, peaking in the early morning hours, was hypothesized to be amines from local industrial emissions based on the time series profile and back trajectory analysis. A strong dependence on wind speed and direction was observed in the single particle types that were present during different times of the day. The early morning (3:30–10 a.m. showed the greatest contributions from industrial emissions. During mid to late mornings (7–11 a.m., weak northerly winds were observed along with the most highly aged particles. Stronger winds from the south picked up in the late morning (after 11 a.m., resulting in a decrease in the concentrations of the major aged particle types and an increase in the number fraction of fresh

  17. Soot measurements for diesel and biodiesel spray combustion under high temperature highly diluted ambient conditions

    KAUST Repository

    Zhang, Ji

    2014-11-01

    This paper presents the soot temperature and KL factor for biodiesel, namely fatty acid methyl ester (FAME) and diesel fuel combustion in a constant volume chamber using a two-color technique. The KL factor is a parameter for soot concentration, where K is an absorption coefficient and proportional to the number density of soot particles, L is the geometric thickness of the flame along the optical detection axis, and KL factor is proportional to soot volume fraction. The main objective is to explore a combustion regime called high-temperature and highly-diluted combustion (HTHDC) and compare it with the conventional and low-temperature combustion (LTC) modes. The three different combustion regimes are implemented under different ambient temperatures (800 K, 1000 K, and 1400 K) and ambient oxygen concentrations (10%, 15%, and 21%). Results are presented in terms of soot temperature and KL factor images, time-resolved pixel-averaged soot temperature, KL factor, and spatially integrated KL factor over the soot area. The time-averaged results for these three regimes are compared for both diesel and biodiesel fuels. Results show complex combined effects of the ambient temperature and oxygen concentration, and that two-color temperature for the HTHDC mode at the 10% oxygen level can actually be lower than the conventional mode. Increasing ambient oxygen and temperature increases soot temperature. Diesel fuel results in higher soot temperature than biodiesel for all three regimes. Results also show that diesel and biodiesel fuels have very different burning and sooting behavior under the three different combustion regimes. For diesel fuel, the HTHDC regime offers better results in terms of lower soot than the conventional and LTC regimes, and the 10% O2, 1400 K ambient condition shows the lowest soot concentration while maintaining a moderate two-color temperature. For biodiesel, the 15% O2, 800 K ambient condition shows some advantages in terms of reducing soot

  18. Vibration syndrome and vibration in pedestal grinding.

    OpenAIRE

    Starck, J; Färkkilä, M; Aatola, S; Pyykkö, I; Korhonen, O.

    1983-01-01

    At one Finnish foundry all the workers had typical symptoms of vibration induced white finger (VWF) after they began using a new type of pedestal grinding machine. The objectives of this study were to establish the severity of the symptoms and the difference in vibration exposure between the new and the old machines. Vibration detection thresholds and grip forces were measured, as well as the vibration in the casting and in the wrist simultaneously. The mean latency for VWF among the grinders...

  19. Detailed characterization of a Comparative Reactivity Method (CRM) instrument for ambient OH reactivity measurements: experiments vs. modeling

    Science.gov (United States)

    Michoud, Vincent; Locoge, Nadine; Dusanter, Sébastien

    2015-04-01

    The Hydroxyl radical (OH) is the main daytime oxidant in the troposphere, leading to the oxidation of Volatile Organic Compounds (VOCs) and the formation of harmful pollutants such as ozone (O3) and Secondary Organic Aerosols (SOA). While OH plays a key role in tropospheric chemistry, recent studies have highlighted that there are still uncertainties associated with the OH budget, i.e the identification of sources and sinks and the quantification of production and loss rates of this radical. It has been demonstrated that ambient measurements of the total OH loss rate (also called total OH reactivity) can be used to identify and reduce these uncertainties. In this context, the Comparative Reactivity Method (CRM), developed by Sinha et al. (ACP, 2008), is a promising technique to measure total OH reactivity in ambient air and has already been used during several field campaigns. This technique relies on monitoring competitive reactions of OH with ambient trace gases and a reference compound (pyrrole) in a sampling reactor to derive ambient OH reactivity. However, this technique requires a complex data processing chain that has yet to be carefully investigated in the laboratory. In this study, we present a detailed characterization of a CRM instrument developed at Mines Douai, France. Experiments have been performed to investigate the dependence of the CRM response on humidity, ambient NOx levels, and the pyrrole-to-OH ratio inside the sampling reactor. Box modelling of the chemistry occurring in the reactor has also been performed to assess our theoretical understanding of the CRM measurement. This work shows that the CRM response is sensitive to both humidity and NOx, which can be accounted for during data processing using parameterizations depending on the pyrrole-to-OH ratio. The agreement observed between laboratory studies and model results suggests a good understanding of the chemistry occurring in the sampling reactor and gives confidence in the CRM

  20. The radiation factor computation of energy systems by means of vibration and noise measurements: The case study of a cogenerative internal combustion engine

    International Nuclear Information System (INIS)

    Highlights: ► A vibration analysis of an internal combustion engine was carried out. ► Sound intensity and surface vibration velocity measurements have been employed. ► The radiation factor of the engine vibrating surfaces was determined. ► The radiation factor can be applied for diagnostic scopes. -- Abstract: The present work deals with the problem of monitoring and diagnosis, through non-intrusive methodologies, of stationary internal combustion engine, with particular attention to the cogenerative 1 MW unit installed at the Engineering Faculty of the University of Perugia. Specifically, acoustic and vibrational measurements have been performed to correlate the engine functional status (and therefore the vibration of mechanical surfaces) with the acoustic emissions features through the characteristic radiation factor. The ISO/TS 7849 normative for the correlation of vibration and acoustic measurement has been employed.

  1. Viscosity measurements of hydrogen at high temperatures up to 573 K by a curved vibrating wire method

    International Nuclear Information System (INIS)

    Highlights: • Viscosity measurements of hydrogen at high temperatures up to 573 K. • Vibrating wire method using a curved thin wire. • Viscosity determination from resonant curve and calibration of wire properties. - Abstract: The viscosities of hydrogen were measured at temperatures of (296 to 573) K and at pressures up to 0.7 MPa by the vibrating wire method. In this study, a tungsten wire 50 μm in diameter and 24 mm in length is bent into semicircular form. The direction of the vibrating motion is fixed using the curved wire, and a more compact sample vessel can be used than in a traditional straight vibrating wire method requiring weight for the tension in the wire. Alternating voltages with different frequencies were supplied to the curved wire, which was set between samarium cobalt magnets. The generated induced voltages depending on the supplied frequencies were measured by a lock-in amplifier, and the resonant curve was obtained. The resonant frequency and half-width of the resonant curve were determined by curve fitting. The wire’s effective diameter and internal friction coefficient, which represents the damping from the wire material and the magnetic force, are very important parameters for evaluating the viscosities, and they were precisely calibrated by measuring helium and nitrogen as reference fluids. Finally, the viscosities of hydrogen were obtained with an uncertainty of 1.4% (k = 2)

  2. Farfield Ion Current Density Measurements before and after the NASA HiVHAc EDU2 Vibration Test

    Science.gov (United States)

    Huang, Wensheng; Kamhawi, Hani; Shastry, Rohit

    2012-01-01

    There is an increasing need to characterize the plasma plume of the NASA HiVHAc thruster in order to better understand the plasma physics and to obtain data for spacecraft interaction studies. To address this need, the HiVHAc research team is in the process of developing a number of plume diagnostic systems. This paper presents the initial results of the farfield current density probe diagnostic system. Farfield current density measurements were carried out before and after a vibration test of the HiVHAc engineering development unit 2 that simulate typical launch conditions. The main purposes of the current density measurements were to evaluate the thruster plume divergence and to investigate any changes in the plasma plume that may occur as a result of the vibration test. Radial sweeps, as opposed to the traditional polar sweeps, were performed during these tests. The charged-weighted divergence angles were found to vary from 16 to 28 degrees. Charge density profiles measured pre- and post-vibration-test were found to be in excellent agreement. This result, alongside thrust measurements reported in a companion paper, confirm that the operation of the HiVHAc engineering development unit 2 were not altered by full-level/random vibration testing.

  3. Vibrational density of states measurement of hydrogen trapped at dislocations in deformed PdH0.0008

    International Nuclear Information System (INIS)

    The vibrational density of states (DOS) of hydrogen trapped at dislocations in deformed PdH0.0008 has been measured at 4 and 295 K with incoherent inelastic neutron scattering. The vibrational DOS at 4 K exhibits features characteristic of the low-temperature β-Pd hydride phase while the characteristic peak in the 295 K DOS corresponds to the solid-solution α-Pd phase. This is evidence of a α→β transition at low temperature within the distorted environment of dislocations

  4. Group and phase velocities from deterministic and ambient sources measured during the AlpArray-EASI experiment

    Science.gov (United States)

    Kolínský, Petr; Zigone, Dimitri; Fuchs, Florian; Bianchi, Irene; Qorbani, Ehsan; Apoloner, Maria-Theresia; Bokelmann, Götz; AlpArray-EASI Working Group

    2016-04-01

    The Eastern Alpine Seismic Investigation (EASI) was a complementary experiment to the AlpArray project. EASI was composed of 55 broadband seismic stations deployed in a winding swath of 540 km length along longitude 13.350 E from the Czech-German border to the Adriatic Sea. Average north-south inter-station distance was 10 km, the distance of each station to either side of the central line was 6 km. Such a dense linear network allows for surface wave dispersion measurements by both deterministic and ambient noise sources along the same paths. During the experiment (July 2014 - August 2015), three earthquakes ML = 2.6, 2.9 and 4.2 occurred in Austria and Northern Italy only several kilometers off the swath. We measure Rayleigh and Love wave group velocities between the source and a single station for the recorded earthquakes, as well as phase velocities between selected pairs of stations using the standard two-station method. We also calculate cross-correlations of ambient noise between selected pairs of stations and we determine the corresponding group velocity dispersion curves. We propose a comparison of phase velocities between two stations measured from earthquakes with group velocities obtained from cross-correlations for the same station pairs. We also compare group velocities measured at single station using earthquakes, which occurred along the swath, with group velocities measured from cross-correlations. That way we analyze velocities of both deterministic and ambient noise reconstructed surface waves propagating along the same path. We invert the resulting dispersion curves for 1D shear wave velocity profiles with depth and we compile a quasi-2D velocity model along the EASI swath.

  5. Development and evaluation of a novel monitor for online measurement of iron, manganese, and chromium in ambient particulate matter (PM).

    Science.gov (United States)

    Wang, Dongbin; Sowlat, Mohammad H; Shafer, Martin M; Schauer, James J; Sioutas, Constantinos

    2016-09-15

    A prototype atmospheric aerosol monitor was developed for online measurement of three toxicologically relevant redox-active metals (Fe, Mn, and Cr) in ambient fine particulate matter (PM2.5). The monitor has the unique ability to quantify these metals in specific chemical oxidation states in addition to both their total and water-soluble fractions in the ambient PM2.5. This information is critical for advancing our understanding of mechanisms of PM-induced toxicity as well as chemical processing of aerosol in the atmosphere. The metal monitor utilizes a high flow rate aerosol-into-liquid collector to collect ambient PM2.5 directly as concentrated aqueous slurry samples. The concentrations of target metals in the collected slurries are subsequently measured in a aerosol-into-liquid collector, micro volume flow cell (MVFC) using spectrophotometry to quantify the light absorption of colored complexes resulting from the reaction between the target metals and added analytical reagents. Our experimental evaluation indicated that, overall, this novel monitor can achieve accurate and reliable measurements over long sampling periods (i.e. at least several weeks). The online measurements for all three target elements were in good agreement (i.e., with slopes of the linear regression lines ranging between 0.90 and 1.07, and R(2) values between 0.76 and 0.95) with time-integrated filter samples collected in parallel and analyzed by magnetic sector inductively coupled plasma mass spectrometry (SF-ICPMS). Moreover, this metal monitor can provide semi-continuous measurements (i.e., every 2h) for at least 5 consecutive days without obvious shortcomings in its field operation. The online monitor measured total concentrations of Fe that ranged between 4.8 and 65.6ng/m(3), for Mn from below detection limit to 10.0ng/m(3), and for Cr from below detection limit to 6.6ng/m(3), respectively. Our results indicate that the developed metal monitor is a promising technology for online

  6. In vitro measurement of ambient pressure changes using a realistic clinical setup

    DEFF Research Database (Denmark)

    Andersen, Klaus Scheldrup; Jensen, Jørgen Arendt

    2008-01-01

    flexible offering completely arbitrary excitation and data acquisition, fast and accurate ambient pressure control, and precise timing. More importantly, it resembles a realistic clinical setup using a single array transducer for transmit and receive. The standard signal processing steps usually seen for...... 32 cycles cosine tapered pulse with a center frequency of 4 MHz and an acoustic pressure of 485 kPa was used for excitation. 64 elements were used in receive and the RF data was filtered and beamformed before further processing. To compensate for variations in bubble response and to make the...

  7. Review of measured vibration and noise environments experienced by passengers in aircraft and in ground transportation systems

    Science.gov (United States)

    Stephens, D. G.

    1975-01-01

    Measured vibration and interior noise data are presented for a number of air and surface vehicles. Consideration is given to the importance of direction effects; of vehicle operations such as take-off, cruise, and landing; and of measurement location on the level and frequency of the measurements. Various physical measurement units or descriptors are used to quantify and compare the data. Results suggest the range of vibration and noise associated with a particular mode of transportation and illustrate the comparative levels in terms of each of the descriptors. Collectively, the results form a data base which may be useful in assessing the ride of existing or future systems relative to vehicles in current operation.

  8. Effects of ambient air pollution on functional status in patients with chronic congestive heart failure: a repeated-measures study

    Directory of Open Access Journals (Sweden)

    Phillips Russell S

    2007-09-01

    Full Text Available Abstract Background Studies using administrative data report a positive association between ambient air pollution and the risk of hospitalization for congestive heart failure (HF. Circulating levels of B-type natriuretic peptide (BNP are directly associated with cardiac hemodynamics and symptom severity in patients with HF and, therefore, serves as a marker of functional status. We tested the hypothesis that BNP levels would be positively associated with short-term changes in ambient pollution levels among 28 patients with chronic stable HF and impaired systolic function. Methods BNP was measured in whole blood at 0, 6, and 12 weeks. We used linear mixed models to evaluate the association between fine particulate matter (PM2.5, carbon monoxide, sulfur dioxide, nitrogen dioxide, ozone, and black carbon and log(BNP. Lags of 0 to 3 days were considered in separate models. We calculated the intraclass correlation coefficient and within-subject coefficient of variation as measures of reproducibility. Results We found no association between any pollutant and measures of BNP at any lag. For example, a 10 μg/m3 increase in PM2.5 was associated with a 0.8% (95% CI: -16.4, 21.5; p = 0.94 increase in BNP on the same day. The within-subject coefficient of variation was 45% on the natural scale and 9% on the log scale. Conclusion These results suggest that serial BNP measurements are unlikely to be useful in a longitudinal study of air pollution-related acute health effects. The magnitude of expected ambient air pollution health effects appears small in relation to the considerable within-person variability in BNP levels in this population.

  9. Measurements of correlation coefficients of vibration on a car body shell

    Science.gov (United States)

    Bonilha, M. W.; Fahy, F. J.

    1993-08-01

    Probabilistic approaches such as Statistical Energy Analysis (SEA) and deterministic approaches such as The Finite Element Method (FEM) are widely used in Automotive Engineering to predict sound pressure levels in the passenger compartment. Due to particular characteristics of each method neither is optimum when applied in mid-frequency ranges (around 100-300 Hz). The use of a hybrid model SEA/FEM is one solution to close the gap between the two methods in this frequency range. The main assumption of such a hybrid model is that the car-body-shell structural wave field is diffuse. In the present work the diffuseness of a car body shell is assessed using correlation coefficients of acceleration measured on a fully trimmed car. Some evidence of diffuse wave field behavior in the 100-300 Hz frequency range is found on the roof vibrational field. However, in view of other results, it is not possible to regard the entire car body structural wave field as diffuse in this frequency range. Reasons for this deviation are given based upon number of excited modes, local perturbations and type of excitation used.

  10. Measurements of seismic vibrations induced by Quarry blasts at the Mostecká basin

    Czech Academy of Sciences Publication Activity Database

    Kaláb, Zdeněk

    -, č. 271 (2006), s. 49-58. ISSN 0372-9508 Institutional research plan: CEZ:AV0Z30860518 Keywords : seismic vibration * slope stability * quarry blast Subject RIV: DC - Siesmology, Volcanology, Earth Structure

  11. Measurement of the effect of an oil additive on vibration, noise and smokiness

    International Nuclear Information System (INIS)

    The contents of this article provides a analysis of vibration, noise and smokiness in compression ignition engines. Further explanation has been given on types of lubrication and oils with their characteristic. Series of experiments has been conducted on vibration. Noise and smokiness before and after adding additive. Presentation has been given of data obtained from examination of the vehicle. At the end comparison of data analysis and conclusion has been done. (Author)

  12. EMRP JRP MetNH3: Towards a Consistent Metrological Infrastructure for Ammonia Measurements in Ambient Air

    Science.gov (United States)

    Leuenberger, Daiana; Balslev-Harder, David; Braban, Christine F.; Ebert, Volker; Ferracci, Valerio; Gieseking, Bjoern; Hieta, Tuomas; Martin, Nicholas A.; Pascale, Céline; Pogány, Andrea; Tiebe, Carlo; Twigg, Marsailidh M.; Vaittinen, Olavi; van Wijk, Janneke; Wirtz, Klaus; Niederhauser, Bernhard

    2016-04-01

    Measuring ammonia in ambient air is a sensitive and priority issue due to its harmful effects on human health and ecosystems. In addition to its acidifying effect on natural waters and soils and to the additional nitrogen input to ecosystems, ammonia is an important precursor for secondary aerosol formation in the atmosphere. The European Directive 2001/81/EC on "National Emission Ceilings for Certain Atmospheric Pollutants (NEC)" regulates ammonia emissions in the member states. However, there is a lack of regulation regarding certified reference material (CRM), applicable analytical methods, measurement uncertainty, quality assurance and quality control (QC/QA) procedures as well as in the infrastructure to attain metrological traceability. As shown in a key comparison in 2007, there are even discrepancies between reference materials provided by European National Metrology Institutes (NMIs) at amount fraction levels up to three orders of magnitude higher than ambient air levels. MetNH3 (Metrology for ammonia in ambient air), a three-year project that started in June 2014 in the framework of the European Metrology Research Programme (EMRP), aims to reduce the gap between requirements set by the European emission regulations and state-of-the-art of analytical methods and reference materials. The overarching objective of the JRP is to achieve metrological traceability for ammonia measurements in ambient air from primary certified reference material CRM and instrumental standards to the field level. This requires the successful completion of the three main goals, which have been assigned to three technical work packages: To develop improved reference gas mixtures by static and dynamic gravimetric generation methods Realisation and characterisation of traceable preparative calibration standards (in pressurised cylinders as well as mobile generators) of ammonia amount fractions similar to those in ambient air based on existing methods for other reactive analytes. The

  13. Measurement of polycyclic aromatic hydrocarbons in ambient air by fluorescence spectroscopic techniques

    OpenAIRE

    Elcoroaristizabal Martin, Saioa

    2015-01-01

    250 p. + anexos Este proyecto de Tesis Doctoral se inició en marzo de 2011 gracias a la becapredoctoral otorgada por la Universidad del País Vasco (UPV/EHU), a través delprograma de ¿Formación de Personal Investigador¿, para trabajar en el Grupo deInvestigación Atmosférica (GIA) del Departamento de Ingeniería Química y del MedioAmbiente de la Escuela Técnica Superior de Ingeniería de Bilbao (Universidad delPaís Vasco, UPV/EHU). Asimismo, parte de este trabajo de investigación se hadesarrol...

  14. Vibrational relaxation in H2--CO and D2--CO mixtures, measured via stimulated Raman-ir fluorescence

    International Nuclear Information System (INIS)

    Rate constants for vibration--vibration and vibration--translation energy transfers were measured by exciting the hydrogenic species in a stimulated Raman cavity and recording the subsequent rise and decay of ir fluorescence from the admixed CO at 4.7 μm. Under the justifiable assumption that the intraspecies redistribution of vibrational energy is very rapid, the time variation of fluorescence intensities and their dependence on the sample composition can be accounted for by the following processes: CO/sup μ/ + H2 → CO + H2, k/sub C, H/ = 14 + or - 0.7 sec-1 torr-1; H2/sup ν/ + H2 → H2 + H2, H/ = 4.3 + or - 0.1; D2/sup ν/ + D2 → D2 + D2, k/sub D,D/ = 0.9 + or - 0.3; H2/sup ν/ + CO → H2 + CO/sup ν/, k/sub H,C//sup ν/ = 4.5 + 2.1 or -1.5; D2/sup ν/ + CO → D2 + CO/sup ν/, k/sub D,C//sup ν/ = 138 + or - 25. The ratio k/sub H,C//sup ν/ to k/sub D,C//sup ν/ is surprisingly small in view of the near resonant condition for Δν(H2) = -1 coupled with Δν(CO) = +2

  15. Vibrational and rotational CARS measurements of nitrogen in afterglow of streamer discharge in atmospheric pressure fuel/air mixtures

    International Nuclear Information System (INIS)

    The use of nonequilibrium plasma generated by nanosecond discharges to ignite fuel/air mixtures, known as transient plasma ignition (TPI), has been shown to effectively reduce ignition delay and improve engine performance relative to spark ignition for combustion engines. While this method is potentially useful for many engine applications, at present the underlying physics are poorly understood. This work uses coherent anti-Stokes Raman spectroscopy (CARS) to measure the rotational and vibrational excitation of nitrogen molecules in the discharge afterglow in a variety of fuel/air mixtures outside the limits of combustion in order to elucidate the thermal behaviour of TPI. The time evolution of relative populations of vibrationally excited states of nitrogen in the electronic ground state are reported for each gas mixture; it is shown that generation of these vibrationally excited states is inefficient during the discharge in air but that generation occurs at a high rate roughly 5 µs following the discharge; with the addition of fuels vibrationally excited states are observed during the discharge but an increase in population is still seen at 5 µs. Possible mechanisms for this behaviour are discussed. In addition, rotational temperature increases of at least 500 K are reported for all gas mixtures. The effect of this temperature increase on ignition, reaction rates, and thermal energy pathways are discussed.

  16. Flow-Induced Vibration Measurement of an Inner Cladding Tube in a Simulated Dual-Cooled Fuel Rod

    International Nuclear Information System (INIS)

    To create an internal coolant flow passage in a dual cooled fuel rod, an inner cladding tube cannot have intermediate supports enough to relieve its vibration. Thus it can be suffered from a flow-induced vibration (FIV) more severely than an outer cladding tube which will be supported by series of spacer grids. It may cause a fatigue failure at welding joints on the cladding's end plug or fluid elastic instability of long, slender inner cladding due to decrease of a critical flow velocity. This is one of the challenging technical issues when a dual cooled fuel assembly is to be realized into a conventional reactor core To study an actual vibration phenomenon of a dual cooled fuel rod, FIV tests using a small-scale test bundle are being carried out. Measurement results of inner cladding tube of two typically simulated rods are presented. Causes of the differences in the vibration amplitude and response spectrum of the inner cladding tube in terms of intermediate support condition and pellet stacking are discussed

  17. Vibration sensor

    OpenAIRE

    Matěj, J.

    2015-01-01

    This paper lays out a design of a system for reading the radar antenna gearbox vibrations. Firstly it names different types of sensors and defines their suitability for this usage. It describes their important electric and frequency properties. Secondly it shows a design of the data transmission system from the transducer to a computer and describes measured data changes according to the gearbox faults.

  18. Experimental Investigation of Wave-Induced Ship Hydroelastic Vibrations by Large-Scale Model Measurement in Coastal Waves

    Directory of Open Access Journals (Sweden)

    Jialong Jiao

    2016-01-01

    Full Text Available Ship hydroelastic vibration is an issue involving mutual interactions among inertial, hydrodynamic, and elastic forces. The conventional laboratory tests for wave-induced hydroelastic vibrations of ships are performed in tank conditions. An alternative approach to the conventional laboratory basin measurement, proposed in this paper, is to perform tests by large-scale model measurement in real sea waves. In order to perform this kind of novel experimental measurement, a large-scale free running model and the experiment scheme are proposed and introduced. The proposed testing methodology is quite general and applicable to a wide range of ship hydrodynamic experimental research. The testing procedure is presented by illustrating a 5-hour voyage trial of the large-scale model carried out at Huludao harbor of China in August 2015. Hammer tests were performed to identify the natural frequencies of the ship model at the beginning of the tests. Then a series of tests under different sailing conditions were carried out to investigate the vibrational characteristics of the model. As a postvoyage analysis, load, pressure, acceleration, and motion responses of the model are studied with respect to different time durations based on the measured data.

  19. Vibration control in accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Montag, C.

    2011-01-01

    In the vast majority of accelerator applications, ground vibration amplitudes are well below tolerable magnet jitter amplitudes. In these cases, it is necessary and sufficient to design a rigid magnet support structure that does not amplify ground vibration. Since accelerator beam lines are typically installed at an elevation of 1-2m above ground level, special care has to be taken in order to avoid designing a support structure that acts like an inverted pendulum with a low resonance frequency, resulting in untolerable lateral vibration amplitudes of the accelerator components when excited by either ambient ground motion or vibration sources within the accelerator itself, such as cooling water pumps or helium flow in superconducting magnets. In cases where ground motion amplitudes already exceed the required jiter tolerances, for instance in future linear colliders, passive vibration damping or active stabilization may be considered.

  20. Comparative Study of Bridge Structure Vortex-induced Vibration Examples and Vibration Reduction Measures%桥梁结构涡激振动实例及减振措施比较研究

    Institute of Scientific and Technical Information of China (English)

    桑建设

    2013-01-01

    针对设计中不被重视的涡激共振问题,讨论了桥梁结构涡激振动及其响应分析的复杂性,介绍了几座国外大跨度桥梁结构的涡激振动问题,并比较分析了这些桥梁结构所采用的不同减振措施方案,推荐设计阶段首先选择气动控制措施来抑制桥梁涡激振动,而已建成的桥梁发生涡振病害则更适宜选用机械减振措施。%In view of the ignored problem of vortex-induced resonance in design, this article analyzes vortex-induced vibration of bridge structure and the complexity of response analysis. The vortex-induced vibration problem of some foreign large span bridge structures is introduced and different vibration reducing measures of these bridges are analyzed and compared. It is recommended that pneumatic control measures be firstly used to control the vortex-induced vibration of bridges in design phase, while for vortex-induced vibration of built-up bridges, mechanical vibration reduction measures are more appropriate.

  1. Comparative Study of Bridge Structure Vortex-induced Vibration Examples and Vibration Reduction Measures%桥梁结构涡激振动实例及减振措施比较研究

    Institute of Scientific and Technical Information of China (English)

    桑建设

    2013-01-01

    In view of the ignored problem of vortex-induced resonance in design, this article analyzes vortex-induced vibration of bridge structure and the complexity of response analysis. The vortex-induced vibration problem of some foreign large span bridge structures is introduced and different vibration reducing measures of these bridges are analyzed and compared. It is recommended that pneumatic control measures be firstly used to control the vortex-induced vibration of bridges in design phase, while for vortex-induced vibration of built-up bridges, mechanical vibration reduction measures are more appropriate.%针对设计中不被重视的涡激共振问题,讨论了桥梁结构涡激振动及其响应分析的复杂性,介绍了几座国外大跨度桥梁结构的涡激振动问题,并比较分析了这些桥梁结构所采用的不同减振措施方案,推荐设计阶段首先选择气动控制措施来抑制桥梁涡激振动,而已建成的桥梁发生涡振病害则更适宜选用机械减振措施。

  2. Hazard surveillance for workplace magnetic fields. 1: Walkaround sampling method for measuring ambient field magnitude; 2: Field characteristics from waveform measurements

    Energy Technology Data Exchange (ETDEWEB)

    Methner, M.M.; Bowman, J.D.

    1998-03-01

    Recent epidemiologic research has suggested that exposure to extremely low frequency (ELF) magnetic fields (MF) may be associated with leukemia, brain cancer, spontaneous abortions, and Alzheimer`s disease. A walkaround sampling method for measuring ambient ELF-MF levels was developed for use in conducting occupational hazard surveillance. This survey was designed to determine the range of MF levels at different industrial facilities so they could be categorized by MF levels and identified for possible subsequent personal exposure assessments. Industries were selected based on their annual electric power consumption in accordance with the hypothesis that large power consumers would have higher ambient MFs when compared with lower power consumers. Sixty-two facilities within thirteen 2-digit Standard Industrial Classifications (SIC) were selected based on their willingness to participate. A traditional industrial hygiene walkaround survey was conducted to identify MF sources, with a special emphasis on work stations.

  3. Fault diagnosis and performance monitoring for pumps by means of vibration measurement and pattern recognition

    International Nuclear Information System (INIS)

    In recent years the early detection of malfunctions with noise and vibration analysis techniques has become a more and more important method for increasing availability and safety of various components in technical plants. The possibility of pattern recognition assisted vibration monitoring and its practical realization are demonstrated by failure diagnosis and trend analysis of the condition of large centrifugal pumps in hydraulic circuits. Some problems as, e.g., the finding of dynamic failure models, signal analysis, feature extraction and statistical pattern recognition, which helps automatically to decide whether the pump works normally or not, are discussed in more detail. In the paper it is shown that for various types of machines the chance of success of condition based maintenance can be enhanced by such an automatic vibration monitoring. (author)

  4. Camera-based measurement for transverse vibrations of moving catenaries in mine hoists using digital image processing techniques

    International Nuclear Information System (INIS)

    This paper proposes a novel, non-contact, sensing method to measure the transverse vibrations of hoisting catenaries in mine hoists. Hoisting catenaries are typically moving cables and it is not feasible to use traditional methods to measure their transverse vibrations. In order to obtain the transverse displacements of an arbitrary point in a moving catenary, by superposing a mask image having the predefined reference line perpendicular to the hoisting catenaries on each frame of the processed image sequence, the dynamic intersecting points with a grey value of 0 in the image sequence could be identified. Subsequently, by traversing the coordinates of the pixel with a grey value of 0 and calculating the distance between the identified dynamic points from the reference, the transverse displacements of the selected arbitrary point in the hoisting catenary can be obtained. Furthermore, based on a theoretical model, the reasonability and applicability of the proposed camera-based method were confirmed. Additionally, a laboratory experiment was also carried out, which then validated the accuracy of the proposed method. The research results indicate that the proposed camera-based method is suitable for the measurement of the transverse vibrations of moving cables. (paper)

  5. Adaptive Model-Based Mine Detection/Localization using Noisy Laser Doppler Vibration Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Sullivan, E J; Xiang, N; Candy, J V

    2009-04-06

    The acoustic detection of buried mines is hampered by the fact that at the frequencies required for obtaining useful penetration, the energy is quickly absorbed by the ground. A recent approach which avoids this problem, is to excite the ground with a high-level low frequency sound, which excites low frequency resonances in the mine. These resonances cause a low-level vibration on the surface which can be detected by a Laser Doppler Vibrometer. This paper presents a method of quickly and efficiently detecting these vibrations by sensing a change in the statistics of the signal when the mine is present. Results based on real data are shown.

  6. Ambient in-situ immersion freezing measurements - findings from the ZAMBIS 2014 field campaign for three ice nucleation techniques

    Science.gov (United States)

    Kohn, Monika; Atkinson, James D.; Lohmann, Ulrike; Kanji, Zamin A.

    2015-04-01

    To estimate the influence of clouds on the Earth's radiation budget, it is crucial to understand cloud formation processes in the atmosphere. A key process, which significantly affects cloud microphysical properties and the initiation of precipitation thus contributing to the hydrological cycle, is the prevailing type of ice nucleation mechanism. In mixed-phase clouds immersion freezing is the dominant ice crystal forming mechanism, whereby ice nucleating particles (INP) first act as cloud condensation nuclei (CCN) and are activated to cloud droplets followed by freezing upon supercooling. There are a number of experimental methods and techniques to investigate the ice nucleating ability in the immersion mode, however most techniques are offline for field sampling or only suitable for laboratory measurements. In-situ atmospheric studies are needed to understand the ice formation processes of 'real world' particles. Laboratory experiments simulate conditions of atmospheric processes like ageing or coating but are still idealized. Our method is able to measure ambient in-situ immersion freezing on single immersed aerosol particles. The instrumental setup consists of the recently developed portable immersion mode cooling chamber (PIMCA) as a vertical extension to the portable ice nucleation chamber (PINC, [1]), where the frozen fraction of activated aerosol particles are detected by the ice optical depolarization detector (IODE, [2]). Two additional immersion freezing techniques based on a droplet freezing array [3,4] are used to sample ambient aerosol particles either in a suspension (fraction larger ~0.6 μm) or on PM10-filters to compare different ice nucleation techniques. Here, we present ambient in-situ measurements at an urban forest site in Zurich, Switzerland held during the Zurich ambient immersion freezing study (ZAMBIS) in spring 2014. We investigated the ice nucleating ability of natural atmospheric aerosol with the PIMCA/PINC immersion freezing setup as

  7. Design of a compensated signal rod for low magnetic moment sample measurements with a vibrating sample magnetometer.

    Science.gov (United States)

    Carignan, Louis-Philippe; Cochrane, Robert W; Ménard, David

    2008-03-01

    A zero-signal sample holder is proposed for the measurement of weak magnetic signals with vibrating sample magnetometers. With proper shape of the support rod, a nearly vanishing signal can be obtained as a function of the magnetic field and the temperature. In particular, it is shown that the addition of an extra part to a standard glass sample holder can reduce the diamagnetic signal by more than three orders of magnitude with no noise increase. The proposed method is applicable to field, temperature, and angular measurements; it is also ideally suited to direct measurement of nanometer thick magnetic layers deposited on much thicker diamagnetic substrates. PMID:18377045

  8. Application of 10B counter with moderator for neutron ambient dose equivalent measurement in radiation monitoring at JINR

    International Nuclear Information System (INIS)

    The possibility to use the instrument based on the 10B-counter (CHM-14) with polyethylene moderator as a dosimeter of the neutron ambient dose equivalent H*(10) in the field of nuclear installations of JINR was investigated. It was shown that the instrument can be used to measure H*(10) of neutrons in the energy range from 0.4 eV to 20 MeV with the uncertainty within 30% due to the dependence of response on neutron energy. The use of the correction factors can extend the energy range of measurement of the neutron dose H*(10) up to hundreds of MeV. The uncertainty due to angular dependence of the instrument response is not more than 35%

  9. Speciated mercury measurements in ambient air from 2009 to 2011 at a Central European rural background monitoring site

    Directory of Open Access Journals (Sweden)

    Weigelt A.

    2013-04-01

    Full Text Available Since January 2009 highly time-resolved mercury speciation measurements in ambient air are carried out at the Central European German EMEP monitoring station and measurement site of the German Federal Environment Agency “Waldhof“, providing the longest Central European dataset for mercury species. First statistical analyses do not indicate long term trends for the concentrations of gaseous elemental mercury (GEM and particle bound mercury (TPM. A potential increasing trend for reactive gaseous mercury (RGM will have to be verified in the coming years and should be regarded as indicative only at present. A seasonal cycle for TPM could be observed with higher concentrations during winter time. Furthermore a diurnal cycle for RGM is apparent with highest concentrations in the early afternoon.

  10. Long duration measurements of whole-body vibration exposures associated with surface coal mining equipment compared to previous short-duration measurements.

    Science.gov (United States)

    Burgess-Limerick, Robin; Lynas, Danellie

    2016-01-01

    Previous measurements of whole-body vibration associated with earth-moving equipment at surface coal mines have highlighted the significance of the hazard. Considerable variability in measurement amplitudes, even within the same equipment type operated at the same site, has been noted. However, the measurements have previously been undertaken for relatively short durations. Fifty-nine measurements were collected from a range of earth-moving equipment in operation at a surface coal mine. Measurement durations ranged from 100-460 min (median = 340 min). The results indicate that the measurements previously observed are not an artifact of the relatively short durations and confirm that operators of dozers and off-road haul trucks, in particular, are frequently exposed to vertical whole-body vibration levels which lie within, or above, the Health Guidance Caution Zone defined by ISO2631.1. Further investigations are justified to identify opportunities for reducing operators' exposure to high amplitude vibrations. PMID:26771238

  11. Comparison of ambient aerosol extinction coefficients obtained from in-situ, MAX-DOAS and LIDAR measurements at Cabauw

    Directory of Open Access Journals (Sweden)

    P. Zieger

    2011-03-01

    Full Text Available In the field, aerosol in-situ measurements are often performed under dry conditions (relative humidity RH<30–40%. Since ambient aerosol particles experience hygroscopic growth at enhanced RH, their microphysical and optical properties – especially the aerosol light scattering – are also strongly dependent on RH. The knowledge of this RH effect is of crucial importance for climate forcing calculations or for the comparison of remote sensing with in-situ measurements. Here, we will present results from a four-month campaign which took place in summer 2009 in Cabauw, The Netherlands. The aerosol scattering coefficient σsp(λ was measured dry and at various, predefined RH conditions between 20 and 95% with a humidified nephelometer. The scattering enhancement factor f(RH,λ is the key parameter to describe the effect of RH on σsp(λ and is defined as σsp(RH,λ measured at a certain RH divided by the dry σsp(dry,λ. The measurement of f(RH,λ together with the dry absorption measurement (assumed not to change with RH allows the determination of the actual extinction coefficient σep(RH,λ at ambient RH. In addition, a wide range of other aerosol properties were measured in parallel. The measurements were used to characterize the effects of RH on the aerosol optical properties. A closure study showed the consistency of the aerosol in-situ measurements. Due to the large variability of air mass origin (and thus aerosol composition a simple parameterization of f(RH,λ could not be established. If f(RH,λ needs to be predicted, the chemical composition and size distribution need to be known. Measurements of four MAX-DOAS (multi-axis differential optical absorption spectroscopy instruments were used to retrieve vertical profiles of σep(λ. The values of the lowest layer were compared to the in-situ values after conversion of the latter ones to ambient

  12. Comparison of ambient aerosol extinction coefficients obtained from in-situ, MAX-DOAS and LIDAR measurements at Cabauw

    Directory of Open Access Journals (Sweden)

    P. Zieger

    2010-12-01

    Full Text Available In the field, aerosol in-situ measurements are often performed under dry conditions (relative humidity RH<30–40%. Since ambient aerosol particles experience hygroscopic growth at enhanced RH, also their microphysical and optical properties – especially the aerosol light scattering – are strongly dependent on RH. The knowledge of this RH effect is of crucial importance for climate forcing calculations or for the comparison of remote sensing with in-situ measurements. Here, we will present results from a four-month campaign which took place in summer 2009 in Cabauw, The Netherlands. The aerosol scattering coefficient σsp(λ was measured dry and at various, predefined RH conditions between 20 and 95% with a humidified nephelometer. The scattering enhancement factor f(RH,λ is the key parameter to describe the effect of RH on σsp(λ and is defined as σsp(RH,λ measured at a certain RH divided by the dry σsp(dry,λ. The measurement of f(RH,λ together with the dry absorption measurement (assumed not to change with RH allows the determination of the actual extinction coefficient σep(RH,λ at ambient RH. In addition, a wide range of other aerosol properties were measured in parallel. The measurements were used to characterize the effects of RH on the aerosol optical properties. A closure study showed the consistency of the aerosol in-situ measurements. Due to the large variability of air mass origin (and thus aerosol composition a simple parameterization of f(RH,λ could not be established. If f(RH,λ needs to be predicted, the chemical composition and size distribution needs to be known. Measurements of four MAX-DOAS (multi-axis differential optical absorption spectroscopy instruments were used to retrieve vertical profiles of σep(λ. The values of the lowest layer were compared to the in-situ values after conversion of the latter to ambient RH

  13. Measurements and source apportionment of particle-associated polycyclic aromatic hydrocarbons in ambient air in Riyadh, Saudi Arabia

    Science.gov (United States)

    Bian, Qijing; Alharbi, Badr; Collett, Jeffrey; Kreidenweis, Sonia; Pasha, Mohammad J.

    2016-07-01

    Ambient air samples were obtained in Riyadh, the capital and largest city of Saudi Arabia, during two measurement campaigns spanning September 2011 to September 2012. Sixteen particle-phase polycyclic aromatic hydrocarbons (PAH) were quantified in 167 samples. Pyrene and fluoranthene were the most abundant PAH, with average of 3.37 ± 14.01 ng m-3 and 8.00 ± 44.09 ng m-3, respectively. A dominant contribution from low molecular weight (LMW) PAH (MW industrial emissions on PAH concentrations. Monte Carlo source apportionment using diagnostic ratios showed that 80 ± 10% of the average LMW PAH concentrations were contributed by petroleum vapor emissions, while 53 ± 19% of high molecular weight (HMW) PAH were from solid fuel combustion emissions. The positive matrix factorization model estimated that oil combustion emissions dominated total PAH concentrations, accounting for on average 96%, likely due to widespread use of oil fuels in energy production (power plants and industries). Our results demonstrate the significant influence of petroleum product production and consumption on particulate-phase PAH concentrations in Riyadh, but also point to the importance of traffic and solid fuel burning, including coke burning and seasonal biomass burning, especially as they contribute to the ambient levels of HMW PAH.

  14. A liquid nitrogen-free preconcentration unit for measurements of ambient N2O isotopomers by QCLAS

    Directory of Open Access Journals (Sweden)

    L. Emmenegger

    2010-05-01

    Full Text Available Important information about the biogeochemical cycle of nitrous oxide (N2O can be obtained by measuring its three main isotopic species, 14N15N16O, 15N14N16O, and 14N14N16O, and the respective site-specific relative isotope ratio differences δ15Nα and δ15Nβ. Absorption laser spectroscopy in the mid-infrared is a direct method for the analysis of the 15N isotopic composition of N2O, yet not sensitive enough for atmospheric N2O mixing ratios (320 ppb. To enable a fully-automated high precision analysis of N2O isotopic species at ambient mixing ratios, we built and optimized a liquid nitrogen-free preconcentration unit to be coupled to a quantum cascade laser (QCL based spectrometer. During standard operation 10 l of ambient air are preconcentrated on a HayeSep D trap and desorbed in 50 ml of synthetic air. Rigorous tests were conducted, using FTIR, quantum cascade laser absorption spectroscopy (QCLAS, GC-FID and component-specific ozone and oxygen analysers to investigate recovery rates, conservation of isotopic signatures and spectral interferences after preconcentration. We achieve quantitative N2O recovery of >99% with only minor, statistically not significant isotopic fractionation and no relevant spectral interferences from other atmospheric constituents. The developed preconcentration unit also has the potential to be applied to other trace gases and their isotopic composition.

  15. Depth-kymography of vocal fold vibrations: part II. Simulations and direct comparisons with 3D profile measurements

    Energy Technology Data Exchange (ETDEWEB)

    Mul, Frits F M de; George, Nibu A; Qiu Qingjun; Rakhorst, Gerhard; Schutte, Harm K [Department of Biomedical Engineering BMSA, Faculty of Medicine, University Medical Center Groningen UMCG, University of Groningen, PO Box 196, 9700 AD Groningen (Netherlands)], E-mail: ffm@demul.net

    2009-07-07

    We report novel direct quantitative comparisons between 3D profiling measurements and simulations of human vocal fold vibrations. Until now, in human vocal folds research, only imaging in a horizontal plane was possible. However, for the investigation of several diseases, depth information is needed, especially when the two folds act differently, e.g. in the case of tumour growth. Recently, with our novel depth-kymographic laryngoscope, we obtained calibrated data about the horizontal and vertical positions of the visible surface of the vibrating vocal folds. In order to find relations with physical parameters such as elasticity and damping constants, we numerically simulated the horizontal and vertical positions and movements of the human vocal folds while vibrating and investigated the effect of varying several parameters on the characteristics of the phonation: the masses and their dimensions, the respective forces and pressures, and the details of the vocal tract compartments. Direct one-to-one comparison with measured 3D positions presents-for the first time-a direct means of validation of these calculations. This may start a new field in vocal folds research.

  16. Depth-kymography of vocal fold vibrations: part II. Simulations and direct comparisons with 3D profile measurements

    International Nuclear Information System (INIS)

    We report novel direct quantitative comparisons between 3D profiling measurements and simulations of human vocal fold vibrations. Until now, in human vocal folds research, only imaging in a horizontal plane was possible. However, for the investigation of several diseases, depth information is needed, especially when the two folds act differently, e.g. in the case of tumour growth. Recently, with our novel depth-kymographic laryngoscope, we obtained calibrated data about the horizontal and vertical positions of the visible surface of the vibrating vocal folds. In order to find relations with physical parameters such as elasticity and damping constants, we numerically simulated the horizontal and vertical positions and movements of the human vocal folds while vibrating and investigated the effect of varying several parameters on the characteristics of the phonation: the masses and their dimensions, the respective forces and pressures, and the details of the vocal tract compartments. Direct one-to-one comparison with measured 3D positions presents-for the first time-a direct means of validation of these calculations. This may start a new field in vocal folds research.

  17. The impact of vibrational Raman scattering of air on DOAS measurements of atmospheric trace gases

    Science.gov (United States)

    Lampel, J.; Frieß, U.; Platt, U.

    2015-09-01

    In remote sensing applications, such as differential optical absorption spectroscopy (DOAS), atmospheric scattering processes need to be considered. After inelastic scattering on N2 and O2 molecules, the scattered photons occur as additional intensity at a different wavelength, effectively leading to "filling-in" of both solar Fraunhofer lines and absorptions of atmospheric constituents, if the inelastic scattering happens after the absorption. Measured spectra in passive DOAS applications are typically corrected for rotational Raman scattering (RRS), also called Ring effect, which represents the main contribution to inelastic scattering. Inelastic scattering can also occur in liquid water, and its influence on DOAS measurements has been observed over clear ocean water. In contrast to that, vibrational Raman scattering (VRS) of N2 and O2 has often been thought to be negligible, but it also contributes. Consequences of VRS are red-shifted Fraunhofer structures in scattered light spectra and filling-in of Fraunhofer lines, additional to RRS. At 393 nm, the spectral shift is 25 and 40 nm for VRS of O2 and N2, respectively. We describe how to calculate VRS correction spectra according to the Ring spectrum. We use the VRS correction spectra in the spectral range of 420-440 nm to determine the relative magnitude of the cross-sections of VRS of O2 and N2 and RRS of air. The effect of VRS is shown for the first time in spectral evaluations of Multi-Axis DOAS data from the SOPRAN M91 campaign and the MAD-CAT MAX-DOAS intercomparison campaign. The measurements yield in agreement with calculated scattering cross-sections that the observed VRS(N2) cross-section at 393 nm amounts to 2.3 ± 0.4 % of the cross-section of RRS at 433 nm under tropospheric conditions. The contribution of VRS(O2) is also found to be in agreement with calculated scattering cross-sections. It is concluded, that this phenomenon has to be included in the spectral evaluation of weak absorbers as it

  18. On dithiothreitol (DTT) as a measure of oxidative potential for ambient particles: evidence for the importance of soluble transition metals

    Science.gov (United States)

    Charrier, J. G.; Anastasio, C.

    2012-10-01

    The rate of consumption of dithiothreitol (DTT) is increasingly used to measure the oxidative potential of particulate matter (PM), which has been linked to the adverse health effects of PM. While several quinones are known to be very reactive in the DTT assay, it is unclear what other chemical species might contribute to the loss of DTT in PM extracts. To address this question, we quantify the rate of DTT loss from individual redox-active species that are common in ambient particulate matter. While most past research has indicated that the DTT assay is not sensitive to metals, our results show that seven out of the ten transition metals tested do oxidize DTT, as do three out of the five quinones tested. While metals are less efficient at oxidizing DTT compared to the most reactive quinones, concentrations of soluble transition metals in fine particulate matter are generally much higher than those of quinones. The net result is that metals appear to dominate the DTT response for typical ambient PM2.5 samples. Based on particulate concentrations of quinones and soluble metals from the literature, and our measured DTT responses for these species, we estimate that for typical PM2.5 samples approximately 80% of DTT loss is from transition metals (especially copper and manganese), while quinones account for approximately 20%. We find a similar result for DTT loss measured in a small set of PM2.5 samples from the San Joaquin Valley of California. Because of the important contribution from metals, we also tested how the DTT assay is affected by EDTA, a chelator that is sometimes used in the assay. EDTA significantly suppresses the response from both metals and quinones; we therefore recommend that EDTA should not be included in the DTT assay.

  19. On dithiothreitol (DTT as a measure of oxidative potential for ambient particles: evidence for the importance of soluble transition metals

    Directory of Open Access Journals (Sweden)

    J. G. Charrier

    2012-05-01

    Full Text Available The rate of consumption of dithiothreitol (DTT is increasingly used to measure the oxidative potential of particulate matter (PM, which has been linked to the adverse health effects of PM. While several quinones are known to be very reactive in the DTT assay, it is unclear what other chemical species might contribute to the loss of DTT in PM extracts. To address this question, we quantify the rate of DTT loss from individual redox-active species that are common in ambient particulate matter. While most past research has indicated that the DTT assay is not sensitive to metals, our results show that seven out of the ten transition metals tested do oxidize DTT, as do three out of the five quinones tested. While metals are less efficient at oxidizing DTT compared to the most reactive quinones, concentrations of soluble transition metals in fine particulate matter are generally much higher than those of quinones. The net result is that metals appear to dominate the DTT response for typical ambient PM2.5 samples. Based on particulate concentrations of quinones and soluble metals from the literature, and our measured DTT responses for these species, we estimate that for typical fine particle samples approximately 80% of DTT loss is from transition metals (especially copper and manganese, while quinones account for approximately 20%. We find a similar result for DTT loss measured in a small set of PM2.5 samples from the San Joaquin Valley of California. Because of the important contribution from metals, we also tested how the DTT assay is affected by EDTA, a chelator that is sometimes used in the assay. EDTA significantly suppresses the response from both metals and quinones; we therefore recommend that EDTA should not be included in the DTT assay.

  20. Calibrating MMS Electron Drift Instrument (EDI) Ambient Electron Flux Measurements and Characterizing 3D Electric Field Signatures of Magnetic Reconnection

    Science.gov (United States)

    Shuster, J. R.; Torbert, R. B.; Vaith, H.; Argall, M. R.; Li, G.; Chen, L. J.; Ergun, R. E.; Lindqvist, P. A.; Marklund, G. T.; Khotyaintsev, Y. V.; Russell, C. T.; Magnes, W.; Le Contel, O.; Pollock, C. J.; Giles, B. L.

    2015-12-01

    The electron drift instruments (EDIs) onboard each MMS spacecraft are designed with large geometric factors (~0.01cm2 str) to facilitate detection of weak (~100 nA) electron beams fired and received by the two gun-detector units (GDUs) when EDI is in its "electric field mode" to determine the local electric and magnetic fields. A consequence of the large geometric factor is that "ambient mode" electron flux measurements (500 eV electrons having 0°, 90°, or 180° pitch angle) can vary depending on the orientation of the EDI instrument with respect to the magnetic field, a nonphysical effect that requires a correction. Here, we present determinations of the θ- and ø-dependent correction factors for the eight EDI GDUs, where θ (ø) is the polar (azimuthal) angle between the GDU symmetry axis and the local magnetic field direction, and compare the corrected fluxes with those measured by the fast plasma instrument (FPI). Using these corrected, high time resolution (~1,000 samples per second) ambient electron fluxes, combined with the unprecedentedly high resolution 3D electric field measurements taken by the spin-plane and axial double probes (SDP and ADP), we are equipped to accurately detect electron-scale current layers and electric field waves associated with the non-Maxwellian (anisotropic and agyrotropic) particle distribution functions predicted to exist in the reconnection diffusion region. We compare initial observations of the diffusion region with distributions and wave analysis from PIC simulations of asymmetric reconnection applicable for modeling reconnection at the Earth's magnetopause, where MMS will begin Science Phase 1 as of September 1, 2015.

  1. Vibration measurements based on demodulating the phase of a fiber 3dB-coupler Michelson interferometer

    Science.gov (United States)

    Li, Min; Xie, Fang; Ren, Junyu

    2009-11-01

    A fiber interferometric vibration measurement system which is based on demodulating the phase of a fiber Michelson interferometer which is made with a fiber 3dB-coupler is presented. In the work, the system employed the characteristics of fiber Brag gratings (FBGs) to interleave two fiber Michelson interferometers which share almost the same part of the main optical path. One of the fiber interferometers is used to stabilize the system, employing an electronic feedback loop to drive a piezoelectric actuator to tune the optical path of the reference beam in order to keep the interferometer in quadrature state. By this way, the low frequency drifts in the phase of the interferometric signals which are resulted from environmental disturbances are compensated for. The other one is used to perform the measurement task. By employing the characteristics of 3dB-coupler, the interferometric signals from the two outputs of the 3dB-couper are 180º out of phase. The two interferometric signals are input into an electronic processor and convert into currents, which are linear to the power of the optical interferometric light. The signals are collected by NI USB-5132 acquisition card and processed by a program in a personal computer. The measurement system is configured with fiber and fiber components which are integrated together. As the cutoff frequency of the feedback loop is 1.5Hz, the measurement system is capable of measuring vibration with frequencies bigger than 1.5Hz and the amplitude of the measured vibration is not limited.

  2. Measurement and Correlation of Ambient VOCs in Windsor, Ontario, Canada and Detroit, Michigan, USA

    Science.gov (United States)

    Miller, L. J.; You, H.; Xu, X.; Molaroni, S.; Lemke, L.; Weglicki, L.; Krouse, H.; Krajenta, R.

    2009-05-01

    An air quality study has been carried out in Windsor, Ontario, Canada and Detroit, Michigan, USA as part of a pilot research study undertaken by the Geospatial Determinants of Health Outcomes Consortium (GeoDHOC), a multidisciplinary, international effort aimed at understanding the health effects of air pollution in urban environments. Exposure to volatile organic compounds has long been associated with adverse health conditions such as atrophy of skeletal muscles, loss of coordination, neurological damage, dizziness, throat, nose, and eye irritation, nervous system depression, liver damage, and respiratory symptoms. Twenty-six species of ambient volatile organic compounds (VOCs) were monitored during a 2-week period in September, 2008 at 100 sites across Windsor and Detroit, using 3M # 3500 Organic Vapour Monitors. Ten species with highest concentrations were selected for further investigation; Toluene (mean concentration =4.14 μm/m3), (m+p)-Xylene (2.30 μm/m3), Hexane (1.87 μm/m3), Benzene (1.37 μm/m3), 1,2,4-Trimethylbenzene (0.87 μm/m3), Dichloromethane (0.77 μm/m3), Ethylbenzene (0.68 μm/m3), o-Xylene (0.63 μm/m3), n-Decane (0.42 μm/m3), and 1,3,5-Trimethylbenzene (0.39 μm/m3). Comparison to a similar investigation in Sarnia, Ontario in October 2005 revealed that the mean concentrations of VOCs were higher in Windsor-Detroit for all species by a significant margin (31-958%), indicating substantial impact of local industrial and vehicular emissions in the WindsorVDetroit area. For most VOCs, the concentrations were higher in Detroit than in Windsor. The mean concentration of total VOC was 9.7 μm/m3 in Windsor, which is slightly higher than that in Sarnia in 2005 (7.9 um/m3), whilst total VOC concentration in Detroit was much higher (16.5 μm/m3). There were strong correlations among several of the 10 species, with the highest Pearson correlation coefficients (r=0.78 - 0.99, p<0.05) amongst the BTEX (benzene, toluene, ethylbenzene, and xylenes) group

  3. A contactless vibrating sample technique for the measurement of normal state resistivity, AC susceptibility and magnetization of single crystals of high Tc superconductors

    International Nuclear Information System (INIS)

    The technique relies on a measurement of the out-of-balance signal from an AC (5-100 kHz) bridge, one arm of which contains a coil into and out of which the specimen is vibrated. Locked-in detection at both the AC and the vibration frequencies leads to high sensitivity, sufficient to measure the resistivity of a small high-Tc crystal in the normal state, as well as the real and imaginary parts of the susceptibility in the superconducting state. A simple modification of the circuit, with no disturbance to the specimen, allows the apparatus to be used as a vibrating sample magnetometer. (author)

  4. Volatile organic compounds in urban atmospheres: Long-term measurements of ambient air concentrations in differently loaded regions of Leipzig

    Energy Technology Data Exchange (ETDEWEB)

    Knobloch, T.; Asperger, A.; Engewald, W. [University of Leipzig, Institute of Analytical Chemistry, Leipzig (Germany)

    1997-09-01

    For the comprehensive characterization of ambient air concentrations of a broad spectrum of volatile organic compounds (VOCs) an analytical method is described, consisting of adsorptive enrichment, thermal desorption without cryofocusing, and capillary gas chromatographic separation. The method was applied during two-week measuring campaigns in winter and summer 1995, and in the winter of 1996. Long-term sampling was carried out at sampling points in residential areas in the suburbs and near the city center of Leipzig. About 70 VOCs - mainly hydrocarbons from propene to hexadecane - were identified both by GC-MS and chromatographic retention data and quantified after external calibration. Mean values of VOC concentrations obtained during the sampling periods are reported and discussed with regard to the topographical location of the sampling points in the Leipzig area, seasonal variations, and possible emission sources. (orig.) With 7 figs., 3 tabs., 18 refs.

  5. Twenty years of measurement of polycyclic aromatic hydrocarbons (PAHs) in UK ambient air by nationwide air quality networks.

    Science.gov (United States)

    Brown, Andrew S; Brown, Richard J C; Coleman, Peter J; Conolly, Christopher; Sweetman, Andrew J; Jones, Kevin C; Butterfield, David M; Sarantaridis, Dimitris; Donovan, Brian J; Roberts, Ian

    2013-06-01

    The impact of human activities on the health of the population and of the wider environment has prompted action to monitor the presence of toxic compounds in the atmosphere. Toxic organic micropollutants (TOMPs) are some of the most insidious and persistent of these pollutants. Since 1991 the United Kingdom has operated nationwide air quality networks to assess the presence of TOMPs, including polycyclic aromatic hydrocarbons (PAHs), in ambient air. The data produced in 2010 marked 20 years of nationwide PAH monitoring. This paper marks this milestone by providing a novel and critical review of the data produced since nationwide monitoring began up to the end of 2011 (the latest year for which published data is available), discussing how the networks performing this monitoring has evolved, and elucidating trends in the concentrations of the PAHs measured. The current challenges in the area and a forward look to the future of air quality monitoring for PAHs are also discussed briefly. PMID:23636622

  6. ENHANCED CHARACTERIZATION OF AMBIENT FINE PARTICULATE MATTER THROUGH COMPLEMENTARY DATA INTEGRATION AND IMPROVED MEASUREMENT INSTRUMENTATION

    Science.gov (United States)

    Improvements in fine particle characterization will allow for a more complete understanding of the processes particle in the atmosphere undergo. The integration of complementary measurements into a compact mathematical form, allows for ease of transfer from particle measureme...

  7. Ambient concentrations of aldehydes in relation to Beijing Olympic air pollution control measures

    OpenAIRE

    J. C. Gong; Zhu, T.; M. Hu; L. W. Zhang; Cheng, H.; L. Zhang; Tong, J; Zhang, J.

    2010-01-01

    Aldehydes are ubiquitous constituents of the atmosphere. Their concentrations are elevated in polluted urban atmospheres. The present study was carried out to characterize three aldehydes of most health concern (formaldehyde, acetaldehyde, and acrolein) in a central Beijing site in the summer and early fall of 2008 (from June to October). Measurements were made before, during, and after the Beijing Olympics to examine whether the air pollution control measures implemented to improve Beijing's...

  8. In situ measurements in an immerged environment of ambient gamma radiation activity and associated spectrometry

    International Nuclear Information System (INIS)

    A set of site measurement devices composed of an ictometer, an air ionization chamber and a gamma ray spectrometry chain was modified so that the type of measurements could be carried out in an immerged environment with the equipment lying on the sediments of the prospected area. The different detectors can be controlled-and the data stored in a portable and autonomous 'PC' microcomputer from a light craft

  9. Ambient Space and Ambient Sensation

    DEFF Research Database (Denmark)

    Schmidt, Ulrik

    The ambient is the aesthetic production of the sensation of being surrounded. As a concept, 'ambient' is mostly used in relation to the music genre 'ambient music' and Brian Eno's idea of environmental background music. However, the production of ambient sensations must be regarded as a central...... aspect of the aesthetization of modern culture in general, from architecture, transport and urbanized lifeforms to film, sound art, installation art and digital environments. This presentation will discuss the key aspects of ambient aesthetization, including issues such as objectlessness...

  10. IN-SITU MEASUREMENTS OF VIBRATIONS OF ELASTICALLY SUPPORTED STEEL REINFORCED CONCRETE BRIDGE DURING CAR BRAKING

    Directory of Open Access Journals (Sweden)

    S. Yu. Gridnev

    2011-02-01

    Full Text Available Problem statement. Dynamic effect of increasing transport flows is produced not only on bearing structures of bridges but also on supports, which leads to their uniform non-steady state deformation.Results and conclusions. An optical displacement controller is proposed to be used for remote record of vibrations of elastically supported steel reinforced concrete bridge and supporting part's deformation. Device structure, scheme of its calibration and of determination of maximum accuracy are described, as well as technique and results of dynamic tests of vibrations of elastically supported span of steel reinforced concrete bridge during single car braking with different accelerations in the beginning of braking in different cross-sections. The analysis of the results is performed.

  11. Evaluation of protection measurements for rural environments; Avaliacao de medidas de protecao para ambientes rurais

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Diogo N.G.; Silva, Fernanda L.; Conti, Luiz F., E-mail: dneves@ird.gov.b, E-mail: lfcconti@ird.gov.b, E-mail: fleite@ird.gov.b [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Wasserman, Maria Angelica V., E-mail: maria.wasserman@pq.cnpq.b [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Rochedo, Elaine R.R., E-mail: erochedo@cnen.gov.b [Comissao Nacional de Energia Nuclear (CODIN/CNEN), Rio de Janeiro, RJ (Brazil). Coord. de Instalacoes Nucleares

    2011-10-26

    Among the planning activities of actuation in nuclear/radiological emergences, it is included the efficiency evaluation of protection and remediation measurements. From the development of a data base on such measurements for the agricultural areas, the program SIEM was used for effectuation the simulations involving the {sup 137}Cs, {sup 131}I and {sup 90}Sr radionuclides, in scenery previously established for simulation those areas of a 50 km surrounding the Admiral Alvaro Alberto nuclear power plant. The obtained results indicate that the scenery is determinant of efficiency measurements involving various specific factors of each place, such as: agricultural and cattle breeding products, consumption habits of population and the grade of subsistence by the diet items, making not practical the elaboration of predefined generic sceneries. The great dependence on seasoning related to the moment of accident makes inadequate any previous evaluation what soever for evaluation of efficiency of protection and remediation measurements. Therefore, previous decisions are not recommended about the relevance of protection measurements for rural areas. Two classification criteria were defined: (i) the efficiency in reduction the doses in the firs year; and, (i i) efficiency in reduction the dose at long term

  12. A New Vibration Measurement Procedure for On-Line Quality Control of Electronic Devices

    Directory of Open Access Journals (Sweden)

    Gian Marco Revel

    2002-01-01

    Full Text Available In this paper the problem of experimentally testing the mechanical reliability of electronic components for quality control is approached. In general, many tests are performed on electronic devices (personal computers, power supply units, lamps, etc., according to the relevant international standards (IEC, in order to verify their resistance to shock and vibrations, but these are mainly “go no-go” experiments, performed on few samples taken from the production batches.

  13. IN-SITU MEASUREMENTS OF VIBRATIONS OF ELASTICALLY SUPPORTED STEEL REINFORCED CONCRETE BRIDGE DURING CAR BRAKING

    OpenAIRE

    S. Yu. Gridnev; Volkov, V. V.

    2011-01-01

    Problem statement. Dynamic effect of increasing transport flows is produced not only on bearing structures of bridges but also on supports, which leads to their uniform non-steady state deformation.Results and conclusions. An optical displacement controller is proposed to be used for remote record of vibrations of elastically supported steel reinforced concrete bridge and supporting part's deformation. Device structure, scheme of its calibration and of determination of maximum accuracy are de...

  14. Measurement and Prediction of the Cooling Characteristics of a Generalized Vibrating Piezoelectric Fan

    OpenAIRE

    Kimber, Mark; Garimella, Suresh V.

    2009-01-01

    Piezoelectric fans are thin elastic beams whose vibratory motion is actuated by means of a piezoelectric material bonded to the beam. These fans have found use as a means to enhance convective heat transfer while requiring only small amounts of power. The objective of the present work is to quantify the influence of each operational parameter and its relative impact on thermal performance. Of particular interest are the vibration frequency and amplitude as well as the geometry of the vibratin...

  15. Quantitative measurement of local carrier concentration of semiconductor from displacement current-voltage curve using a scanning vibrating tip

    Energy Technology Data Exchange (ETDEWEB)

    Majima, Yutaka; Oyama, Yutaka; Iwamoto, Mitsumasa

    2000-07-01

    A new scanning probe method for evaluating the local carrier concentration of semiconductors is presented. The distance between a semiconductor surface and a vibrating tip is changed sinusoidally, and is adjusted to as small as a few nm across which tunneling current I{sub T} flows between the semiconductor surface and the vibrating tip. Displacement current I{sub D} due to the change in electric flux from the semiconductor surface to the vibrating tip flows periodically in accordance with the vibration of the tip. I{sub T} also flows when the distance becomes minimum. Both I{sub T} and I{sub D} flow simultaneously when a d.c. tip voltage V is applied, and these two currents are separated by using a two-phase lock-in amplifier. I{sub D}-V curve is analyzed by taking into account two-dimensional electric flux profile under the tip. In the tip voltage range within which majority carriers are accumulated, I{sub D}-V curve is extrapolated by a straight line. On the contrary, the slope of the curve decreases as the tip voltage is reduced from the voltage range of the accumulation, indicating that the majority carriers are depleted at the center of the Si surface. The theoretical I{sub D}-V curves are in good agreement with the measurement in the tip voltage region where the majority carriers are both accumulated and depleted. The local carrier concentration is able to be determined by making the theoretical I{sub D}-V curve fit the experimental results without contacting the semiconductor surface.

  16. Evaluation of protection measurements for urban environments; Avaliacao de medidas de protecao para ambientes urbanos

    Energy Technology Data Exchange (ETDEWEB)

    Rochedo, Elaine R.R., E-mail: erochedo@cnen.gov.b [Comissao Nacional de Energia Nuclear (CODIN/CNEN), Rio de Janeiro, RJ (Brazil). Coord. de Instalacoes Nucleares; Silva, Diogo N.G.; Nascimento, Udilma; Conti, Luiz F., E-mail: dneves@ird.gov.b, E-mail: lfcconti@ird.gov.b, E-mail: udilma@ird.gov.b [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Wasserman, Maria Angelica V., E-mail: maria.wasserman@pq.cnpq.b [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2011-10-26

    Radioactive accidents has shown the necessity of a previous evaluation planning of exposure and directives for implementation of protection measurements. The description or measurements in the literature usually is associated to reduction of concentrations in the medium where they are applied. For verification the efficiency in dose reduction, it is necessary to proceed simulations. Through the development of data base on protection measurements, it was established basic sceneries, typically tropical as far the building type is concerned and the construction material. The program SIEM was used for simulation of contamination with {sup 137}Cs. The results indicates that generic solutions persuade not to and the decision make processes should be effectuated according to the real conditions of contamination and the use of affected area. For affected areas, two classification criteria were defined: (1) efficiency in reducing the dose in the first year; and (2) efficiency in dose reducing at long term

  17. Contact-free measurement of respiratory rate using infrared and vibration sensors

    Science.gov (United States)

    Erden, Fatih; Alkar, Ali Ziya; Cetin, Ahmet Enis

    2015-11-01

    Respiratory rate is an essential parameter in many practical applications such as apnea detection, patient monitoring, and elderly people monitoring. In this paper, we describe a novel method and a contact-free multi-modal system which is capable of detecting human breathing activity. The multimodal system, which uses both differential pyro-electric infrared (PIR) and vibration sensors, can also estimate the respiratory rate. Vibration sensors pick up small vibrations due to the breathing activity. Similarly, PIR sensors pick up the thoracic movements. Sensor signals are sampled using a microprocessor board and analyzed on a laptop computer. Sensor signals are processed using wavelet analysis and empirical mode decomposition (EMD). Since breathing is almost periodic, a new multi-modal average magnitude difference function (AMDF) is used to detect the periodicity and the period in the processed signals. By fusing the data of two different types of sensors we achieve a more robust and reliable contact-free human breathing activity detection system compared to systems using only one specific type of sensors.

  18. Estimation of Eastern Denmark’s Electromechanical Modes from Ambient Phasor Measurement Data

    DEFF Research Database (Denmark)

    Vanfretti, Luigi; Garcia-Valle, Rodrigo; Uhlen, Kjetil; Johansson, Emil; Trudnowski, Daniel; Pierre, John W.; Chow, Joe H.; Samuelsson, Olof; Østergaard, Jacob; Martin, Kenneth E.

    2010-01-01

    In this paper we report on the preliminary results of a collaborative investigation effort between researchers in North America and Europe aiming to baseline the electromechanical modes and mode shapes of the Nordic system from synchronized phasor measurement data. We provide an overview on the...

  19. Ambient concentrations of aldehydes in relation to Beijing Olympic air pollution control measures

    Directory of Open Access Journals (Sweden)

    J. C. Gong

    2010-08-01

    Full Text Available Aldehydes are ubiquitous constituents of the atmosphere. Their concentrations are elevated in polluted urban atmospheres. The present study was carried out to characterize three aldehydes of most health concern (formaldehyde, acetaldehyde, and acrolein in a central Beijing site in the summer and early fall of 2008 (from June to October. Measurements were made before, during, and after the Beijing Olympics to examine whether the air pollution control measures implemented to improve Beijing's air quality during the Olympics had any impact on concentrations of the three aldehydes. Average concentrations of formaldehyde, acetaldehyde and acrolein were 29.34 ± 15.12 μg/m3, 27.09 ± 15.74 μg/m3 and 2.32 ± 0.95 μg/m3, respectively, for the entire period of measurements, all being the highest among the levels measured in cities around the world in photochemical smog seasons. Among the three measured aldehydes, only acetaldehyde had a substantially reduced mean concentration during the Olympic air pollution control period compared to the pre-Olympic period. Formaldehyde and acrolein followed the changing pattern of temperature and were each significantly correlated with ozone (a secondary product of photochemical reactions. In contrast, acetaldehyde was significantly correlated with several pollutants emitted mainly from local emission sources (e.g., NO2, CO, and PM2.5. These findings suggest that local direct emissions had a larger impact on acetaldehyde than formaldehyde and acrolein.

  20. High voltage surface potential measurements in ambient conditions: Application to organic thin-film transistor injection and transport characterization

    Science.gov (United States)

    de Tournadre, Grégoire; Reisdorffer, Frédéric; Rödel, Reinhold; Simonetti, Olivier; Klauk, Hagen; Giraudet, Louis

    2016-03-01

    A scanning surface potential measurement technique suited for thin-film devices operating under high voltages is reported. A commercial atomic force microscope has been customized to enable a feedback-controlled and secure surface potential measurement based on phase-shift detection under ambient conditions. Measurements of the local potential profile along the channel of bottom-gate organic thin-film transistors (TFTs) are shown to be useful to disentangle the contributions from the channel and contacts to the device performance. Intrinsic contact current-voltage characteristics have been measured on bottom-gate, top-contact (staggered) TFTs based on the small-molecule semiconductor dinaphtho[2,3-b:2',3-f]thieno[3,2-b]thiophene (DNTT) and on bottom-gate, bottom-contact (coplanar) TFTs based on the semiconducting polymer polytriarylamine (PTAA). Injection has been found to be linear in the staggered DNTT TFTs and nonlinear in the coplanar PTAA TFTs. In both types of TFT, the injection efficiency has been found to improve with increasing gate bias in the accumulation regime. Contact resistances as low as 130 Ω cm have been measured in the DNTT TFTs. A method that eliminates the influence of bias-stress-induced threshold-voltage shifts when measuring the local charge-carrier mobility in the channel is also introduced, and intrinsic channel mobilities of 1.5 cm2 V-1 s-1 and 1.1 × 10-3 cm2 V-1 s-1 have been determined for DNTT and PTAA. In both semiconductors, the mobility has been found to be constant with respect to the gate bias. Despite its simplicity, the Kelvin probe force microscopy method reported here provides robust and accurate surface potential measurements on thin-film devices under operation and thus paves the way towards more extensive studies of particular interest in emerging fields of solid-state electronics.

  1. In-flight measured and predicted ambient dose equivalent and latitude differences on effective dose estimates

    International Nuclear Information System (INIS)

    The results from 2 years (2001-2002) of experimental measurements of in-board radiation doses received at Iberia commercial flights are presented. The routes studied cover the most significant destinations and provide a good estimate of the route doses as required by the new Spanish regulations on air crew radiation protection. Details on the experimental procedures and calibration methods are given. The experimental measurements from the different instruments (Tissue Equivalent Proportional Counter and the combination of a high pressure ion chamber and a high-energy neutron compensated rem-counter) and their comparison with the predictions from some route-dose codes (CARI-6, EPCARD 3.2) are discussed. In contrast with the already published data, which are mainly focused on North latitudes over parallel 50, many of the data presented in this work have been obtained for routes from Spain to Central and South America. (authors)

  2. Viscoelastic material properties’ identification using high speed full field measurements on vibrating plates

    Directory of Open Access Journals (Sweden)

    Pierron F.

    2010-06-01

    Full Text Available The paper presents an experimental application of a method leading to the identification of the elastic and damping material properties of isotropic vibrating plates. The theory assumes that the searched parameters can be extracted from curvature and deflection fields measured on the whole surface of the plate at two particular instants of the vibrating motion. The experimental application consists in an original excitation fixture, a particular adaptation of an optical full-field measurement technique, a data preprocessing giving the curvature and deflection fields and finally in the identification process using the Virtual Fields Method (VFM. The principle of the deflectometry technique used for the measurements is presented. First results of identification on an acrylic plate are presented and compared to reference values. Details about a new experimental arrangement, currently in progress, is presented. It uses a high speed digital camera to over sample the full-field measurements.

  3. Instrument for measuring total alpha particle energies of alpha emitters in ambient air

    Energy Technology Data Exchange (ETDEWEB)

    Kronenberg, S.; Brucker, G.J.; Cummings, B.; Bechtel, E.; Gentner, F.; Horne, S

    2000-11-11

    This paper describes the design, fabrication, testing and evaluation of a self-reading, carbon fiber, electrometer-type instrument. It is used for measuring the total energy of alpha particles emitted in air by progenies of {sup 222}Rn ({sup 218}Po, {sup 214}Pb, and {sup 214}Bi), and sometimes by other types of alpha emitters (e.g. {sup 212}Pb, {sup 238}U, and {sup 239}Pu). The purpose of these measurements is to assess the energy delivered by alpha emission from these sources to the lung tissue. A sample (charged progenies attached to aerosols) is collected on filter paper from a known volume of air and placed on the instrument. The discharge rate indicates the alpha energy in MeV l{sup -1} of air per min that is produced by the alpha emitters. The calibration procedure shows that the instrument has an energy sensitivity for alpha particles of 800.5 MeV/scale unit. The range of the readout scale is 30 units. Measurements of alpha contamination in air were made using this instrument in buildings, private homes and in a standard chamber. The value of the radon concentration in this chamber is traceable back to the US Environmental Protection Agency (EPA) and to the National Institute of Standards and Technology (NIST)

  4. Ambient Aerosol in Southeast Asia: High Resolution Aerosol Mass Spectrometer Measurements Over Oil Palm (Elaeis guineensis)

    Science.gov (United States)

    Phillips, G.; Dimarco, C.; Misztal, P.; Nemitz, E.; Farmer, D.; Kimmel, J.; Jimenez, J.

    2008-12-01

    The emission of organic compounds in the troposphere is important factor in the formation of secondary organic aerosol (SOA). A very large proportion of organic material emitted globally is estimated to arise from biogenic sources, with almost half coming from tropical and sub-tropical forests. Preliminary analyses of leave cuvette emission studies suggest that oil palm (Elaeis guineensis) is a significantly larger source of isoprene than tropical forest. Much larger sources of isoprene over oil palm allied with a larger anthropogenic component of local emissions contrast greatly with the remote tropical forest environment and therefore the character of SOA formed may differ significantly. These issues, allied with the high price of palm oil on international markets leading to increased use of land for oil palm production, could give rise to rapidly changing chemical and aerosol regimes in the tropics. It is therefore important to understand the current emissions and composition of organic aerosol over all important land-uses in the tropical environment. This in turn will lead to a greater understanding of the present, and to an improvement in predictive capacity for the future system. To help address these issues, a high resolution time of flight aerosol mass spectrometer (HR-ToF-AMS) was deployed in the Sabahmas (PPB OIL) oil palm plantation near Lahad Datu, in Eastern Sabah, as part of the field component of the Aerosol Coupling in the Earth System (ACES) project, part of the UK NERC APPRAISE program. This project was allied closely with measurements made of similar chemical species and aerosol components at a forest site in the Danum Valley as part of the UK Oxidant and Particle Photochemical Processes above a Southeast Asian tropical rainforest (OP3) project. Measurements of submicron non- refractory aerosol composition are presented along with some preliminary analysis of chemically resolved aerosol fluxes made with a new eddy covariance system, based on the

  5. Water Uptake and Carbon Assimilation in Maize at Elevated and ambient CO2: Modeling and Measurement.

    Science.gov (United States)

    Timlin, Dennis; Chun, Jong-Ahn; Kim, Soo-Hyung; Yang, Yang; Fleisher, David; Reddy, Vangimalla

    2013-04-01

    Potential transpiration in crops is dependent on both plant and environmental properties. Carbon dioxide content of the atmosphere is linked to potential transpiration because CO2 diffuses onto water saturated surfaces within plant stomata. At high CO2 concentrations, CO2 diffuses rapidly into stomata and therefore stomata do not have to remain open to the atmosphere for long periods of time. This results in lower transpiration rates per unit CO2 assimilated at elevated CO2 concentrations. The objective of this study was to measure CO2 assimilation and water uptake by maize under different irrigation regimes and two CO2 concentrations. The data were then used to evaluate the ability of the maize model MaizSim to simulate the effects of water stress and CO2 on water use and photosynthesis. MaizSim uses a Farquhar type photosynthesis model coupled a Ball-Berry stomatal control model. Non-linear beta functions are used to estimate the effects of temperature on growth and development processes. The experimental data come from experiments in outdoor, sunlit growth chambers at the USDA-ARS Beltsville Agricultural Research Center. The eight treatments comprised two levels of carbon dioxide concentrations (400 and 800 ppm) and four levels of water stress (well-watered control, mild, moderate, and severe). The water stress treatments were applied at both CO2 levels. Water contents were monitored hourly by a Time Domain Reflectometry (TDR) system. The model simulated higher water contents at the same time after applying water stress at the high CO2 treatment than for the low CO2 treatment as was found in the measured data. Measurement of water uptake by roots and carbon assimilation rates in the chambers will be addressed.

  6. Robust, accurate, and non-contacting vibration measurement systems: Supplemental appendices presenting comparison measurements of the robust laser interferometer and typical accelerometer systems. Volume 2

    International Nuclear Information System (INIS)

    Epoch Engineering, Incorporated (EEI) has completed a series of vibration measurements comparing their newly-developed Robust Laser Interferometer (RLI) with accelerometer-based instrumentation systems. EEI has successfully demonstrated, on several pieces of commonplace machinery, that non-contact, line-of-sight measurements are practical and yield results equal to or, in some cases, better than customary field implementations of accelerometers. The demonstration included analysis and comparison of such phenomena as nonlinearity, transverse sensitivity, harmonics, and signal-to-noise ratio. Fast Fourier Transformations were performed on the accelerometer and the laser system outputs to provide a comparison basis. The RLI was demonstrated, within the limits o the task, to be a viable, line-of-sight, non-contact alternative to accelerometer systems. Several different kinds of machinery were instrumented and. compared, including a small pump, a gear-driven cement mixer, a rotor kit, and two small fans. Known machinery vibration sources were verified and RLI system output file formats were verified to be compatible with commercial computer programs used for vibration monitoring and trend analysis. The RLI was also observed to be less subject to electromagnetic interference (EMI) and more capable at very low frequencies. This document, Volume 2, provides the appendices to this report

  7. Robust, accurate, and non-contacting vibration measurement systems: Summary of comparison measurements of the robust laser interferometer and typical accelerometer systems. Volume 1

    International Nuclear Information System (INIS)

    Epoch Engineering, Incorporated (EEI) has completed a series of vibration measurements comparing their newly-developed Robust Laser Interferometer (RLI) with accelerometer-based instrumentation systems. EEI has successfully demonstrated, on several pieces of commonplace machinery, that non-contact, line-of-sight measurements are practical and yield results equal to or, in some cases, better than customary field implementations of accelerometers. The demonstration included analysis and comparison of such phenomena as nonlinearity, transverse sensitivity, harmonics, and signal-to-noise ratio. Fast Fourier Transformations were performed on the accelerometer and the laser system outputs to provide a comparison basis. The RLI was demonstrated, within the limits of the task, to be a viable, line-of-sight, non-contact alternative to accelerometer systems. Several different kinds of machinery were instrumented and compared, including a small pump, a gear-driven cement mixer, a rotor kit, and two small fans. Known machinery vibration sources were verified and RLI system output file formats were verified to be compatible with commercial computer programs used for vibration monitoring and trend analysis. The RLI was also observed to be less subject to electromagnetic interference (EMI) and more capable at very low frequencies

  8. Body temperature of the parasitic wasp Pimpla turionellae (Hymenoptera) during host location by vibrational sounding.

    Science.gov (United States)

    Kroder, Stefan; Samietz, Jörg; Stabentheiner, Anton; Dorn, Silvia

    2008-03-01

    The pupal parasitoid Pimpla turionellae (L.) uses self-produced vibrations transmitted on the plant substrate, so-called vibrational sounding, to locate immobile concealed pupal hosts. The wasps are able to use vibrational sounding reliably over a broad range of ambient temperatures and even show an increased signal frequency and intensity at low temperatures. The present study investigates how control of body temperature in the wasps by endothermic mechanisms may facilitate host location under changing thermal environments. Insect body temperature is measured with real-time IR thermography on plant-stem models at temperature treatments of 10, 18, 26 and 30 °C, whereas behaviour is recorded with respect to vibrational host location. The results reveal a low-level endothermy that likely interferes with vibrational sound production because it occurs only in nonsearching females. At the lowest temperature of 10 °C, the thoracic temperature is 1.15 °C warmer than the ambient surface temperature whereas, at the high temperatures of 26 and 30 ° C, the wasps cool down their thorax by 0.29 and 0.47 °C, respectively, and their head by 0.45 and 0.61 °C below ambient surface temperature. By contrast, regardless of ambient temperature, searching females always have a slightly elevated body temperature of at most 0.30 °C above the ambient surface temperature. Behavioural observations indicate that searching females interrupt host location more frequently at suboptimal temperatures, presumably due to the requirements of thermoregulation. It is assumed that both mechanisms, producing vibrations for host location and low-level endothermy, are located in the thorax. Endothermy by thoracic muscle work probably disturbs signal structure of vibrational sounding, so the processes cannot be used at the same time. PMID:22140295

  9. Attofarad resolution capacitance-voltage measurement of nanometer scale field effect transistors utilizing ambient noise.

    Science.gov (United States)

    Gokirmak, Ali; Inaltekin, Hazer; Tiwari, Sandip

    2009-08-19

    A high resolution capacitance-voltage (C-V) characterization technique, enabling direct measurement of electronic properties at the nanoscale in devices such as nanowire field effect transistors (FETs) through the use of random fluctuations, is described. The minimum noise level required for achieving sub-aF (10(-18) F) resolution, the leveraging of stochastic resonance, and the effect of higher levels of noise are illustrated through simulations. The non-linear DeltaC(gate-source/drain)-V(gate) response of FETs is utilized to determine the inversion layer capacitance (C(inv)) and carrier mobility. The technique is demonstrated by extracting the carrier concentration and effective electron mobility in a nanoscale Si FET with C(inv) = 60 aF. PMID:19636094

  10. Predicting ambient aerosol thermal-optical reflectance measurements from infrared spectra: elemental carbon

    Science.gov (United States)

    Dillner, A. M.; Takahama, S.

    2015-10-01

    Elemental carbon (EC) is an important constituent of atmospheric particulate matter because it absorbs solar radiation influencing climate and visibility and it adversely affects human health. The EC measured by thermal methods such as thermal-optical reflectance (TOR) is operationally defined as the carbon that volatilizes from quartz filter samples at elevated temperatures in the presence of oxygen. Here, methods are presented to accurately predict TOR EC using Fourier transform infrared (FT-IR) absorbance spectra from atmospheric particulate matter collected on polytetrafluoroethylene (PTFE or Teflon) filters. This method is similar to the procedure developed for OC in prior work (Dillner and Takahama, 2015). Transmittance FT-IR analysis is rapid, inexpensive and nondestructive to the PTFE filter samples which are routinely collected for mass and elemental analysis in monitoring networks. FT-IR absorbance spectra are obtained from 794 filter samples from seven Interagency Monitoring of PROtected Visual Environment (IMPROVE) sites collected during 2011. Partial least squares regression is used to calibrate sample FT-IR absorbance spectra to collocated TOR EC measurements. The FT-IR spectra are divided into calibration and test sets. Two calibrations are developed: one developed from uniform distribution of samples across the EC mass range (Uniform EC) and one developed from a uniform distribution of Low EC mass samples (EC < 2.4 μg, Low Uniform EC). A hybrid approach which applies the Low EC calibration to Low EC samples and the Uniform EC calibration to all other samples is used to produce predictions for Low EC samples that have mean error on par with parallel TOR EC samples in the same mass range and an estimate of the minimum detection limit (MDL) that is on par with TOR EC MDL. For all samples, this hybrid approach leads to precise and accurate TOR EC predictions by FT-IR as indicated by high coefficient of determination (R2; 0.96), no bias (0.00 μg m-3, a

  11. Predicting ambient aerosol Thermal Optical Reflectance (TOR) measurements from infrared spectra: elemental carbon

    Science.gov (United States)

    Dillner, A. M.; Takahama, S.

    2015-06-01

    Elemental carbon (EC) is an important constituent of atmospheric particulate matter because it absorbs solar radiation influencing climate and visibility and it adversely affects human health. The EC measured by thermal methods such as Thermal-Optical Reflectance (TOR) is operationally defined as the carbon that volatilizes from quartz filter samples at elevated temperatures in the presence of oxygen. Here, methods are presented to accurately predict TOR EC using Fourier Transform Infrared (FT-IR) absorbance spectra from atmospheric particulate matter collected on polytetrafluoroethylene (PTFE or Teflon) filters. This method is similar to the procedure tested and developed for OC in prior work (Dillner and Takahama, 2015). Transmittance FT-IR analysis is rapid, inexpensive, and non-destructive to the PTFE filter samples which are routinely collected for mass and elemental analysis in monitoring networks. FT-IR absorbance spectra are obtained from 794 filter samples from seven Interagency Monitoring of PROtected Visual Environment (IMPROVE) sites collected during 2011. Partial least squares regression is used to calibrate sample FT-IR absorbance spectra to collocated TOR EC measurements. The FTIR spectra are divided into calibration and test sets. Two calibrations are developed, one which is developed from uniform distribution of samples across the EC mass range (Uniform EC) and one developed from a~uniform distribution of low EC mass samples (EC < 2.4 μg, Low Uniform EC). A hybrid approach which applies the low EC calibration to low EC samples and the Uniform EC calibration to all other samples is used to produces predictions for low EC samples that have mean error on par with parallel TOR EC samples in the same mass range and an estimate of the minimum detection limit (MDL) that is on par with TOR EC MDL. For all samples, this hybrid approach leads to precise and accurate TOR EC predictions by FT-IR as indicated by high coefficient of variation (R2; 0.96), no

  12. Identifying Hydrocarbon Source Region Emission Signatures for Oil and Gas Facilities and Beyond Using Ambient Concentration Measurements

    Science.gov (United States)

    Nathan, B.; Lary, D. J.

    2014-12-01

    The Texas Commission on Environmental Quality (TCEQ) has fourteen stations in the Barnett Shale that take ambient concentration measurements of forty-six non-methane hydrocarbons. We gathered all measurements for the period of October 16-31, 2013, and applied Lagrangian trajectories to each air parcel that was measured, to achieve a domain filling of the Barnett region. Regular grids of concentration values for each VOC at each hour were constructed, then implemented into an unsupervised machine learning classification. This self-organizing map assigned classification numbers to each grid cell in each hourly grid, where a class number essentially corresponded with a signature of representative concentration values for all forty-six hydrocarbons. Two hundred was determined to be an appropriate number of classes for this classification. Similarly, we applied a self-organizing map to the wind speed and resultant direction measurements recorded at each station. This classification grouped together the hours in our time frame into six distinct wind regimes. Concentration class numbers were analyzed for different wind regimes, and for the whole time period. A grouping of classes with numbers in the middle-to-upper forties was discovered near and downwind of oil and gas facilities. The validity and accuracy of this method was confirmed by performing a site-by-site comparison against an independent study which analyzed the VOC concentrations at three TCEQ stations. This opened the door to expand the dataset to include other ground-based measurements of both non-methane VOC and methane concentrations, to further trace back emission sources.

  13. 地铁列车振动和噪声源分析及减振降噪措施%Subway Train Vibration and Noise Source Analysis and Vibration and Noise Reduction Measures

    Institute of Scientific and Technical Information of China (English)

    吴刚

    2014-01-01

    地铁列车的振动与噪声涉及到多个学科,是一个整体的系统工程。研究列车振动和噪声控制首先需要了解噪声产生机理和噪声单元的声贡献,从而了解所有振动和噪声的特性,进而加强地铁机车的噪声控制和预测,减小地铁列车噪声污染。阐述了地铁列车振动和噪声源的产生原理,列举了现如今地铁列车噪声预测的方法、列车噪声的测量技术和减振降噪技术。%The vibration and noise subway train involves multiple disciplines, is a whole system works. Train vibration and noise control research first need to understand the mechanism of noise and noise sound unit contribution to understand the characteristics of all the vibration and noise, noise control and predict further strengthen metro locomotives, subway trains to reduce noise pollution. Describes the generation principle subway train vibration and noise sources, is now listed subway train noise prediction methods, measurement techniques and train noise vibration and noise reduction technology.

  14. Det ambiente

    DEFF Research Database (Denmark)

    Schmidt, Ulrik

    Om begrebet "det ambiente", der beskriver, hvad der sker, når vi fornemmer baggrundsmusikkens diskrete beats, betragter udsigten gennem panoramavinduet eller tager 3D-brillerne på og læner os tilbage i biografsædet. Bogen analyserer, hvorfan ambiente oplevelser skabes, og hvilke konsekvenser det...

  15. Observing Brownian motion and measuring temperatures in vibration-fluidized granular matter

    International Nuclear Information System (INIS)

    Understanding the behaviour of granular media, either at rest or moving under external driving, is a difficult task, although it is important and of very practical interest. Describing the motion of each individual grain is complicated, not only because of the large number of grains, but also because the mechanisms of interaction at the grain level involve complex contact forces. One would like to have, in fact, a description in terms of a few macroscopic quantities. Since a granular medium resembles a liquid or a gas when strongly vibrated or when flowing out of a container, a natural approach is to adopt usual equilibrium statistical mechanics tools in order to test if such a macroscopic description is possible. In other words, an interesting question is to investigate whether one can model granular media, when close to a liquid-like state for example, using viscosity, temperature, and so on, as one does for normal liquids. With this aim in view, we have developed a non-equilibrium version of the classical Brownian motion experiment. In particular, we have observed the motion of a torsion oscillator immersed in an externally vibrated granular medium of glass spheres, and have collected evidence that the motion is Brownian-like. An approximate fluctuation-dissipation relation holds, and we can define temperature-like and viscosity-like parameters

  16. 3D synthetic aperture PIV measurements from artificial vibrating vocal folds

    CERN Document Server

    Daily, Jesse; Belden, Jesse; Thomson, Scott; Truscott, Tadd

    2011-01-01

    During speech, air from the lungs is forced past the vocal folds which vibrate, producing sound. A pulsatile jet of air is formed downstream of the vibrating folds which interacts with the various structures in the airway. Currently, it is postulated that the way this jet interacts with the downstream structures in the airway directly affects the quality of human speech. In order to better understand this jet, it is desirable to visualize the jet in three dimensions. We present the results of a method that reconstructs the three dimensional velocity field using Synthetic aperture PIV (SAPIV) \\cite{Belden:2010}. SAPIV uses an array of high-speed cameras to artificially create a single camera with a variable focal length. This is accomplished by overlapping the images from the array to create a "focal stack". As the images are increasingly overlapped, more distant image planes come into focus. 3D PIV is then performed on the "refocused" focal stack to reconstruct the flow field in three dimensions. SAPIV has th...

  17. Investigation of multilayer printed circuit board (PCB) film warpage using viscoelastic properties measured by a vibration test

    International Nuclear Information System (INIS)

    Woven glass fabric/BT (bismaleimide triazine) composite laminate (BT core), copper (Cu), and photoimageable solder resist (PSR) are the most widely used materials for semiconductors in electronic devices. Among these materials, BT core and PSR contain polymeric materials that exhibit viscoelastic behavior. For this reason, these materials are considered to have time- and temperature-dependent moduli during warpage analysis. However, the thin geometry of multilayer printed circuit board (PCB) film makes it difficult to identify viscoelastic characteristics. In this work, a vibration test method was proposed for measuring the viscoelastic properties of a multilayer PCB film at different temperatures. The beam-shaped specimens, composed of a BT core, Cu laminated on a BT core, and PSR and Cu laminated on a BT core, were used in the vibration test. The frequency-dependent variation of the complex bending stiffness was determined using a transfer function method. The storage modulus (E′) of the BT core, Cu, and PSR as a function of temperature and frequency were obtained, and their temperature-dependent variation was identified. The obtained properties were fitted using a viscoelastic model for the BT core and the PSR, and a linear elastic model for the Cu. Warpage of a line pattern specimen due to temperature variation was measured using a shadow Moiré analysis and compared to predictions using a finite element model. The results provide information on the mechanism of warpage, especially warpage due to temperature-dependent variation in viscoelastic properties. (paper)

  18. Test And Measuring Methods To Analyse Undulation Effects On Micromachined Optical Surfaces Generated By Vibration On Precision Machinery

    Science.gov (United States)

    Weck, Manfred; Hartel, Robert

    1986-11-01

    Transmitting and illuminating optical surfaces are machined by different processes. Grinding and polishing technologies are mainly used for glass or other non metallic materials to get the right surface figure and optical function. Milling processes like "fly-cutting"using a single point crystal diamond tool are major processes to machine metal optics. The static, kinematic and dynamic behaviour of inserted machining tool is responsible for the design quality of the optical products. Testing and analyzing methods to describe the dynaknic compliance behaviour of machine tool are well known for common milling, turning and grinding machines. This paper describes an improved testing method to analyze undulation problems on micro-machined surfaces for precision machines. The process influencing machine behaviour is recognized by the frequency depending com-pliance characteristic. A non contact laser vibration measurement is used to registrate vibrating machine tool parts. Measuring methods like modal analysis are applied to give a good impression of machine tool deformation behaviour. Results of different tests are presented. An illustration for plottable test statements will be given for a precision milling machine. Selected parts of the machine structure were rebuilt and improved the dynamic behaviour of the tested machine. Increasing undulation marks and a good surface figure are recorded on process tests.

  19. Investigation of multilayer printed circuit board (PCB) film warpage using viscoelastic properties measured by a vibration test

    Science.gov (United States)

    Joo, Sung-Jun; Park, Buhm; Kim, Do-Hyoung; Kwak, Dong-Ok; Song, In-Sang; Park, Junhong; Kim, Hak-Sung

    2015-03-01

    Woven glass fabric/BT (bismaleimide triazine) composite laminate (BT core), copper (Cu), and photoimageable solder resist (PSR) are the most widely used materials for semiconductors in electronic devices. Among these materials, BT core and PSR contain polymeric materials that exhibit viscoelastic behavior. For this reason, these materials are considered to have time- and temperature-dependent moduli during warpage analysis. However, the thin geometry of multilayer printed circuit board (PCB) film makes it difficult to identify viscoelastic characteristics. In this work, a vibration test method was proposed for measuring the viscoelastic properties of a multilayer PCB film at different temperatures. The beam-shaped specimens, composed of a BT core, Cu laminated on a BT core, and PSR and Cu laminated on a BT core, were used in the vibration test. The frequency-dependent variation of the complex bending stiffness was determined using a transfer function method. The storage modulus (E‧) of the BT core, Cu, and PSR as a function of temperature and frequency were obtained, and their temperature-dependent variation was identified. The obtained properties were fitted using a viscoelastic model for the BT core and the PSR, and a linear elastic model for the Cu. Warpage of a line pattern specimen due to temperature variation was measured using a shadow Moiré analysis and compared to predictions using a finite element model. The results provide information on the mechanism of warpage, especially warpage due to temperature-dependent variation in viscoelastic properties.

  20. Det Ambiente

    DEFF Research Database (Denmark)

    Schmidt, Ulrik

    Det ambiente er iscenesættelsen af en karakteristisk sanseoplevelse, der er kendetegnet ved fornemmelsen af at være omgivet. I dag bliver begrebet om det ambiente mest anvendt i forbindelse med musikgenren ’ambient musik’. Det ambiente er dog ikke essentielt knyttet til det musikalske, men må...... forstås som et betydeligt bredere fænomen i den moderne æstetiske kultur, der spiller en væsentlig rolle i oplevelsen af moderne transportformer, arkitektur, film, lydkunst, installationskunst og digitale multimedieiscenesættelser. En forståelse af det ambiente er derfor centralt for forståelsen af en...... moderne æstetiseret oplevelseskultur i almindelighed. Da det ambiente ikke hidtil har været gjort til genstand for en mere indgående teoretisk behandling, er der dog stor usikkerhed omkring, hvad fænomenet overhovedet indebærer. Hovedformålet med Det ambiente – Sansning, medialisering, omgivelse er derfor...

  1. Measurement of vibrationally excited O{sub 2}(v = 6) in the afterglow of pulsed positive corona discharge

    Energy Technology Data Exchange (ETDEWEB)

    Ono, Ryo [Department of Advanced Energy, University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa, Chiba, 227-8568 (Japan); Oda, Tetsuji [Department of Electrical Engineering, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8656 (Japan)], E-mail: ryo-ono@k.u-tokyo.ac.jp

    2009-08-01

    The density of vibrationally excited O{sub 2}(v = 6) in the afterglow of a pulsed positive corona discharge is measured using time-resolved laser-induced predissociation fluorescence. Discharge occurs in a 13 mm point-to-plane gap in humid air under atmospheric pressure. When the discharge voltage is 32 kV, the O{sub 2}(v = 6) density at a distance of 2.5 mm from the anode tip is 4 x 10{sup 14} cm{sup -3} at t = 2 {mu}s, where t is the postdischarge time, then decreases to 3 x 10{sup 13} cm{sup -3} by t = 15 {mu}s. The corresponding vibrational temperatures of O{sub 2}, T{sub v}, are 1400 K at t = 2 {mu}s and 1100 K at t = 15 {mu}s, which are calculated by assuming the vibrational equilibrium of O{sub 2}. It is shown that the T{sub v} of O{sub 2} in the secondary streamer channel is much higher than that in the primary streamer channel. Since the cross section of dissociative attachment (e + O{sub 2} {yields} O + O{sup -}) for a low electron energy (<5 eV) increases markedly with the T{sub v} of O{sub 2}, the high T{sub v} in the secondary streamer may lead to a marked increase in O atom production in the secondary streamer in spite of its low mean electron energy (1-2 eV)

  2. Use of a helical resonator as a capacitive transducer in vibrating reed measurements

    Science.gov (United States)

    Xiang, X.-D.; Brill, J. W.; Fuqua, W. L.

    1989-09-01

    A new design of vibrating reed apparatus for studying high-resonant overtones of very small samples is described. Using the high Q (about 1000) helical RF resonator as a capacitive transducer, great sensitivity has been obtained. The theoretical sensitivity of the detector is investigated with transmission-line theory, and the result shows that the Johnson-noise-limited sensitivity is proportional to the Q of the resonator instead of Q exp 1/2, as is the case of lumped LC-tuned circuit analyses. For a nonsuperconducting resonator, the Johnson-noise-limited minimum detectable displacement at room temperature, with bandwidth B, is about 10 to the -7th A sq rt B/Hz, if the RF electrical field level is only limited by vacuum breakdown. An application of the apparatus in studying the temperature-dependent changes in the Young's modulus of single crystals of TaS3 is shown.

  3. A liquid nitrogen-free preconcentration unit for measurements of ambient N2O isotopomers by QCLAS

    Directory of Open Access Journals (Sweden)

    L. Emmenegger

    2009-12-01

    Full Text Available Important information about the biogeochemical cycle of nitrous oxide (N2O can be obtained by measuring its three main isotopomers, 14N15N16O, 15N14N16O, and 14N14N16O, and the respective site-specific isotope ratios δ15Nα and δ15Nβ. Absorption laser spectroscopy in the mid-infrared is a direct method for N2O isotopomer analysis, yet not sensitive enough for atmospheric N2O concentrations (320 ppb. To enable a fully-automated high precision N2O isotopomer analysis at ambient concentrations, we built and optimized a liquid nitrogen-free preconcentration unit to be coupled to a quantum cascade laser (QCL based spectrometer. Rigorous tests were conducted, using FTIR and quantum cascade laser absorption spectroscopy (QCLAS, to investigate recovery rates, conservation of isotopic signatures and spectral interferences after preconcentration. We achieve quantitative N2O recovery of >99% with only minor, statistically not significant isotopic fractionation and no relevant spectral interferences from other atmospheric constituents. The developed preconcentration unit also has the potential to be applied to other trace gases and their isotopic composition.

  4. Optimisation of a secondary standard chamber for the measurement of the ambient dose equivalent, H*(10), for low photon energies

    International Nuclear Information System (INIS)

    A secondary standard ionisation chamber for photon radiation for measuring an ionisation current, which is directly proportional to the conventionally true value of the ambient dose equivalent, H* (10), was optimised. The chamber was developed in the Austrian Research Centers Seibersdorf and is used successfully worldwide by dosimetry laboratories. The chamber response with respect to H*(10) for photon energies from 40 to 1250 keV is nearly constant. For lower photon energies the response is strongly energy-dependent and does not fulfil the requirements concerning the quality of a secondary standard given in ISO 4037-2, i.e. for energies for which the determination of the conventionally true value of H*(10) is very difficult. Considering the dose limits defined in the Directive 96/29/Euratom, in the case of whole-body irradiation the knowledge of the personal dose equivalent is of importance down to energies of ∼12 keV. For area dosimetry, this means that the knowledge of H*(10) for energies approximately ≥12 keV is necessary. To get one secondary standard chamber for H*(10) for the whole photon energy range and to close the gap for low energies in the dissemination of the conventionally true value of H*(10), the chamber was optimised for a flat response for energies from ∼12 to 1250 keV. (authors)

  5. Measuring Ambient Densities and Lorentz Factors of Gamma-Ray Bursts from GeV and Optical Observations

    CERN Document Server

    Hascoët, Romain; Beloborodov, Andrei M

    2015-01-01

    Fermi satellite discovered that cosmological gamma-ray bursts (GRBs) are accompanied by long GeV flashes. In two GRBs, an optical counterpart of the GeV flash has been detected. Recent work suggests that the GeV+optical flash is emitted by the external blast wave from the explosion in a medium loaded with copious $e^\\pm$ pairs. The full light curve of the flash is predicted by a first-principle radiative transfer simulation and can be tested against observations. Here we examine a sample of 7 bursts with best GeV+optical data and test the model. We find that the observed light curves are in agreement with the theoretical predictions and allow us to measure three parameters for each burst: the Lorentz factor of the explosion, its isotropic kinetic energy, and the external density. With one possible exception of GRB 090510 (which is the only short burst in the sample) the ambient medium is consistent with a wind from a Wolf-Rayet progenitor. The wind density parameter $A=\\rho r^2$ varies in the sample around $1...

  6. An Experimental Measurement on Laminar Burning Velocities and Markstein Length of Iso-Butane-Air Mixtures at Ambient Conditions

    Directory of Open Access Journals (Sweden)

    Yousif Alaeldeen Altag

    2016-01-01

    Full Text Available In the present work, experimental investigation on laminar combustion of iso-butane-air mixtures was conducted in constant volume explosion vessel. The experiments were conducted at wide range of equivalence ratios ranging between Ф = 0.6 and 1.4 and atmospheric pressure of 0.1 MPa and ambient temperature of 303K. Using spherically expanding flame method, flame parameters including stretched, unstretched flame propagation speeds, laminar burning velocities and Markstein length were calculated. For laminar burning velocities the method of error bars of 95% confidence level was applied. In addition, values of Markstein lengths were measured in wide range of equivalence ratios to study the influence of stretch rate on flame instability and burning velocity. It was found that the stretched flame speed and laminar burning velocities increased with equivalence ratios and the peak value was obtained at equivalence ratio of Ф = 1.1. The Markstein length decreased with the increases in equivalence ratios, which indicates that the diffusion thermal flame instability increased at high equivalence ratios in richer mixture side. However, the total deviations in the laminar burning velocities have discrepancies of 1.2-2.9% for all investigated mixtures.

  7. Effects of Ambient Air Pollution on Functional Status in Patients with Chronic Congestive Heart Failure: a Repeated-Measures Study

    OpenAIRE

    Phillips Russell S; Suh Helen H; Coull Brent A; Yeh Gloria Y; Wellenius Gregory A; Mittleman Murray A

    2007-01-01

    Abstract Background Studies using administrative data report a positive association between ambient air pollution and the risk of hospitalization for congestive heart failure (HF). Circulating levels of B-type natriuretic peptide (BNP) are directly associated with cardiac hemodynamics and symptom severity in patients with HF and, therefore, serves as a marker of functional status. We tested the hypothesis that BNP levels would be positively associated with short-term changes in ambient pollut...

  8. Ambient Gestures

    OpenAIRE

    Karam, Maria; Hare, Jonathon; Lewis, Paul; schraefel, m.c.

    2006-01-01

    We present Ambient Gestures, a novel gesture-based system designed to support ubiquitous ‘in the environment’ interactions with everyday computing technology. Hand gestures and audio feedback allow users to control computer applications without reliance on a graphical user interface, and without having to switch from the context of a non-computer task to the context of the computer. The Ambient Gestures system is composed of a vision recognition software application, a set of gestures to be p...

  9. Spectral aerosol extinction (SpEx): a new instrument for in situ ambient aerosol extinction measurements across the UV/visible wavelength range

    Science.gov (United States)

    Jordan, C. E.; Anderson, B. E.; Beyersdorf, A. J.; Corr, C. A.; Dibb, J. E.; Greenslade, M. E.; Martin, R. F.; Moore, R. H.; Scheuer, E.; Shook, M. A.; Thornhill, K. L.; Troop, D.; Winstead, E. L.; Ziemba, L. D.

    2015-11-01

    We introduce a new instrument for the measurement of in situ ambient aerosol extinction over the 300-700 nm wavelength range, the spectral aerosol extinction (SpEx) instrument. This measurement capability is envisioned to complement existing in situ instrumentation, allowing for simultaneous measurement of the evolution of aerosol optical, chemical, and physical characteristics in the ambient environment. In this work, a detailed description of the instrument is provided along with characterization tests performed in the laboratory. Measured spectra of NO2 and polystyrene latex spheres (PSLs) agreed well with theoretical calculations. Good agreement was also found with simultaneous aerosol extinction measurements at 450, 530, and 630 nm using CAPS PMex instruments in a series of 22 tests including nonabsorbing compounds, dusts, soot, and black and brown carbon analogs. SpEx measurements are expected to help identify the presence of ambient brown carbon due to its 300 nm lower wavelength limit compared to measurements limited to longer UV and visible wavelengths. Extinction spectra obtained with SpEx contain more information than can be conveyed by a simple power law fit (typically represented by Ångström exponents). Planned future improvements aim to lower detection limits and ruggedize the instrument for mobile operation.

  10. Vibrational properties of uracil

    Institute of Scientific and Technical Information of China (English)

    WANG Zhiping; ZHANG Fengshou; ZENG Xianghua; ZHOU Hongyu; GU Bin; CHENG Wei

    2006-01-01

    A semiempirical molecular dynamics model is developed to study the vibrational frequencies of uracil at very low kinetic temperature by using the Fourier transform of velocity autocorrelation function of trajectories of molecular dynamics simulations. The finite difference harmonic method is used to assign the vibrational frequency of each mode. The calculated frequencies are found to be in good agreement with experimental measurements. Moreover, we make up for the lost vibrational modes in experiments self-consistently. A total of 30 vibrational modes and their corresponding frequencies are reported.

  11. Measurement of overall uptake coefficients for HO2 radicals by aerosol particles sampled from ambient air at Mts. Tai and Mang (China)

    OpenAIRE

    Taketani, F.; Y. Kanaya; P. Pochanart; Liu, Y; Li, J.; K. Okuzawa; K. Kawamura; Z. Wang; H. Akimoto

    2012-01-01

    HO2 uptake coefficients for ambient aerosol particles, collected on quartz fiber filter using a high-volume air sampler in China, were measured using an aerosol flow tube coupled with a chemical conversion/laser-induced fluorescence technique at 760 Torr and 298 K, with a relative humidity of 75%. Aerosol particles were regenerated with an atomizer using the water extracts from the aerosol particles. Over 10 samples, the measured HO2 uptake coefficients for the aerosol parti...

  12. Measurement of overall uptake coefficients for HO2 radicals by aerosol particles sampled from ambient air at Mts. Tai and Mang, China

    OpenAIRE

    H. Akimoto; Z. Wang; K. Okuzawa; K. Kawamura; Li, J.; Liu, Y; P. Pochanart; Taketani, F.; Y. Kanaya

    2012-01-01

    HO2 uptake coefficients for ambient aerosol particles, collected on quartz filter using a high-volume air sampler in China, were measured using an aerosol flow tube coupled with a chemical conversion/laser-induced fluorescence technique at 760 Torr and 298 K, with a relative humidity of 75%. Aerosol particles were regenerated with an atomizer using the water extracts from the aerosol particles. Over 10 samples, the measured HO2 uptake coefficients for the aerosol particles at the Mt. ...

  13. Electrostatic interaction between Interball-2 and the ambient plasma. 2. Influence on the low energy ion measurements with Hyperboloid

    Directory of Open Access Journals (Sweden)

    M. Hamelin

    Full Text Available The measurement of the thermal ion distributions in space is always strongly influenced by the ion motion through the complex 3D electrostatic potential structure built around a charged spacecraft. In this work, we study the related aberrations of the ion distribution detected on board, with special application to the case of the Hyperboloid instrument borne by the Interball-2 auroral satellite. Most of the time, the Interball-2 high altitude auroral satellite is charged at some non-negligible positive potential with respect to the ambient plasma, as shown in part 1; in consequence, the measurement of magnetospheric low energy ions (< 80 eV with the Hyperboloid instrument can be disturbed by the complex electric potential environment of the satellite. In the case of positive charging, as in previous experiments, a negative bias is applied to the Hyperboloid structure in order to reduce this effect and to keep as much as possible the opportunity to detect very low energy ions. Then, the ions reaching the Hyperboloid entrance windows would have travelled across a continuous huge electrostatic lens involving various spatial scales from ~ 10 cm (detector radius to ~ 10 m (satellite antennas. Neglecting space charge effects, we have computed the ion trajectories that are able to reach the Hyperboloid windows within their acceptance angles. There are three main results: (i for given values of the satellite potential, and for each direction of arrival (each window, we deduced the related energy cutoff; (ii we found that all ions in the energy channel, including the cutoff, can come from a large range of directions in the unperturbed plasma, especially when the solar panels or antennas act as electrostatic mirrors; (iii for higher energy channels, the disturbances are reduced to small angular shifts. Biasing of the aperture is not very effective with the Hyperboloid instrument (as on previous missions with instruments installed close to the spacecraft

  14. Measurements of rotational and vibrational temperatures in a high density nitrogen negative corona discharge

    International Nuclear Information System (INIS)

    Previous studies of the electrical conduction of nitrogen, using point-plane electrodes, have shown that corona discharges occur in all the range of density from low pressure gas to the liquid. Moreover, electrical and transport parameters are mainly a function of fluid density. At each density, above a threshold voltage Vo, the electric current I is correlated to an emitted light current IL and IL is proportional to I. The spectral analysis of this emitted light can be used to evaluate the temperatures (electronic Te, rotational Tr and vibrational Tv) in the corona discharge. However, in corona discharge where temperatures are different from each other, these evaluated temperatures are only open-quotes effectiveclose quotes ones (i.e. not thermodynamic temperatures in the sense of equilibrium). The aim of our work is to investigate the processes of corona discharges in superdense fluids and, in particular, to determine corona temperatures as a function of nitrogen density (from 1.4 x 1020 up to 2 x 1021 cm-3). These temperatures are deduced from a comparison between computer generated synthetic spectra and experimental low-resolution spectra of the second positif system and the first negative system of nitrogen

  15. Measured and modelled tritium concentrations in freshwater Barnes mussels (Elliptio complanata) exposed to an abrupt increase in ambient tritium levels

    International Nuclear Information System (INIS)

    To improve understanding of environmental tritium behaviour, the International Atomic Energy Agency (IAEA) included a Tritium and C-14 Working Group (WG) in its EMRAS (Environmental Modelling for Radiation Safety) program. One scenario considered by the WG involved the prediction of time-dependent tritium concentrations in freshwater mussels that were subjected to an abrupt increase in ambient tritium levels. The experimental data used in the scenario were obtained from a study in which freshwater Barnes mussels (Elliptio complanata) were transplanted from an area with background tritium concentrations to a small Canadian Shield lake that contains elevated tritium. The mussels were then sampled over 88 days, and concentrations of free-water tritium (HTO) and organically-bound tritium (OBT) were measured in the soft tissues to follow the build-up of tritium in the mussels over time. The HTO concentration in the mussels reached steady state with the concentration in lake water within one or two hours. Most models predicted a longer time (up to a few days) to equilibrium. All models under-predicted the OBT concentration in the mussels one hour after transplantation, but over-predicted the rate of OBT formation over the next 24 h. Subsequent dynamics were not well modelled, although all participants predicted OBT concentrations that were within a factor of three of the observation at the end of the study period. The concentration at the final time point was over-predicted by all but one of the models. The relatively low observed concentration at this time was likely due to the loss of OBT by mussels during reproduction.

  16. Measuring Ambient Densities and Lorentz Factors of Gamma-Ray Bursts from GeV and Optical Observations

    Science.gov (United States)

    Hascoët, Romain; Vurm, Indrek; Beloborodov, Andrei M.

    2015-11-01

    The Fermi satellite detected GeV flashes from cosmological gamma-ray bursts (GRBs). In two GRBs, an optical counterpart of the GeV flash was detected. Such flashes are predicted by the model of a blast wave running into a medium loaded with copious {e}+/- pairs. Here we examine a sample of seven bursts with the best GeV+optical data and further test the model. We find that the observed light curves are in agreement with the theoretical predictions, which allows us to measure three parameters for each burst: the Lorentz factor of the explosion, its isotropic kinetic energy, and the external density. With the possible exception of GRB 090510 (the only short burst in the sample), the ambient medium is consistent with a wind from a Wolf-Rayet progenitor. The wind density parameter A=ρ {r}2 varies in the sample around 1011 g cm-1. The initial Lorentz factor of the blast wave varies from 200 to 540, and correlates with the burst luminosity. Radiative efficiency of the prompt emission varies between 0.1 and 0.8. For the two bursts with a detected optical flash, GRB 120711A and GRB 130427A, we also estimate the magnetization of the external blast wave. Remarkably, despite its small number of free parameters, the model reproduces the entire optical light curve of GRB 120711A (with its sharp peak, fast decay, plateau, and break) as well as the GeV data. The spectra of GeV flashes are predicted to extend above 0.1 TeV, where they can be detected by ground-based Cherenkov telescopes.

  17. Measurement of dynamic patterns of an elastic membrane at bi-modal vibration using high speed electronic speckle pattern interferometry

    Science.gov (United States)

    Preciado, Jorge Sanchez; Lopez, Carlos Perez; Santoyo, Fernando Mendoza

    2014-05-01

    Implementing a hybrid arrangement of Laser Doppler Vibrometry (LDV) and high speed Electronic Speckle Pattern Interferometry (ESPI) we were able to measure the dynamic patterns of a flat rectangular elastic membrane clamped at its edges stimulated with the sum of two resonance frequencies. ESPI is a versatile technique to analyze in real-time the deformation of a membrane since its low computational cost and easy implementation of the optical setup. Elastic membranes present nonlinear behaviors when stimulated with low amplitude signals. The elastic membrane under test, with several non rational related vibrating modals below the 200 Hz, was stimulated with two consecutives resonant frequencies. The ESPI patterns, acquired at high speed rates, shown a similar behavior for the dual frequency stimulation as in the case of patterns formed with the entrainment frequency. We think this may be related to the effects observed in the application of dual frequency stimulation in ultrasound.

  18. Measurement of dynamic patterns of an elastic membrane at bi-modal vibration using high speed electronic speckle pattern interferometry

    Energy Technology Data Exchange (ETDEWEB)

    Preciado, Jorge Sanchez; Lopez, Carlos Perez; Santoyo, Fernando Mendoza [Grupo de Metrología Optica, Centro de Investigaciones en Óptica, A. C. Loma del Bosque 115, Col. Lomas del Campestre, León, Guanajuato, 37150 (Mexico)

    2014-05-27

    Implementing a hybrid arrangement of Laser Doppler Vibrometry (LDV) and high speed Electronic Speckle Pattern Interferometry (ESPI) we were able to measure the dynamic patterns of a flat rectangular elastic membrane clamped at its edges stimulated with the sum of two resonance frequencies. ESPI is a versatile technique to analyze in real-time the deformation of a membrane since its low computational cost and easy implementation of the optical setup. Elastic membranes present nonlinear behaviors when stimulated with low amplitude signals. The elastic membrane under test, with several non rational related vibrating modals below the 200 Hz, was stimulated with two consecutives resonant frequencies. The ESPI patterns, acquired at high speed rates, shown a similar behavior for the dual frequency stimulation as in the case of patterns formed with the entrainment frequency. We think this may be related to the effects observed in the application of dual frequency stimulation in ultrasound.

  19. An Evaluation of Uncertainty Associated to Analytical Measurements of Selected Polycyclic Aromatic Compounds in Ambient Air; Estudio sobre las Incertidumbres Asociadas al Metodo de Determinacion de PAC's Seleccionados en Muestras de Aire Ambiente

    Energy Technology Data Exchange (ETDEWEB)

    Barrado, A. I.; Garcia, S.; Perez, R. M.

    2013-06-01

    This paper presents an evaluation of uncertainty associated to analytical measurement of eighteen polycyclic aromatic compounds (PACs) in ambient air by liquid chromatography with fluorescence detection (HPLC/FD). The study was focused on analyses of PM{sub 1}0, PM{sub 2}.5 and gas phase fractions. Main analytical uncertainty was estimated for eleven polycyclic aromatic hydrocarbons (PAHs), four nitro polycyclic aromatic hydrocarbons (nitro-PAHs) and two hydroxy polycyclic aromatic hydrocarbons (OH-PAHs) based on the analytical determination, reference material analysis and extraction step. Main contributions reached 15-30% and came from extraction process of real ambient samples, being those for nitro- PAHs the highest (20-30%). Range and mean concentration of PAC mass concentrations measured in gas phase and PM{sub 1}0/PM{sub 2}.5 particle fractions during a full year are also presented. Concentrations of OH-PAHs were about 2-4 orders of magnitude lower than their parent PAHs and comparable to those sparsely reported in literature. (Author) 7 refs.

  20. Liquid damping of the stator vibrations at the true mass flow meter 50, a mass flow measuring instrument for non-steady-state two-phase flow

    International Nuclear Information System (INIS)

    The liquid damping system used in the TMFM 50 True Mass Flowmeter for damping the stator vibrations excited by the two-phase mixture is reviewed from performance and theoretical points of view. The results furnished by a computer code elaborated for parameter studies are compared with that obtained in a series of vibrations tests on original components. The TMFM 50, nominal range of measurement 50 kg/s, is suitable for direct measurement of the two-phase mass flow under transient PWR conditions. (orig.)

  1. Quantitative measurement of the vibrational amplitude and phase in photorefractive time-average interferometry: A comparison with electronic speckle pattern interferometry

    DEFF Research Database (Denmark)

    Rohleder, Henrik; Petersen, Paul Michael; Marrakchi, A.

    1994-01-01

    Time-average interferometry is dealt with using four-wave mixing in photorefractive Bi12SiO20. By introducing a proper sinusoidal phase shift in the forward pump beam it is possible to measure the amplitude and phase everywhere on a vibrating object. Quantitative measurements of the phase and...... amplitude of the vibrating structure are demonstrated in photorefractive time average interferometry. The photorefractive interferometer is compared with the performance of a commercial electronic speckle pattern interferometer (ESPI). It is shown that the dynamic photorefractive holographic interferometer...

  2. Vibrationally-Fluidized Granular Flows: Impact and Bulk Velocity Measurements Compared with Discrete Element and Continuum Models

    Science.gov (United States)

    Hashemnia, Kamyar

    A new laser displacement probe was developed to measure the impact velocities of particles within vibrationally-fluidized beds. The sensor output was also used to measure bulk flow velocity along the probe window and to provide a measure of the media packing. The displacement signals from the laser sensors were analyzed to obtain the probability distribution functions of the impact velocity of the particles. The impact velocity was affected by the orientation of the laser probe relative to the bulk flow velocity, and the density and elastic properties of the granular media. The impact velocities of the particles were largely independent of their bulk flow speed and packing density. Both the local impact and bulk flow velocities within a tub vibratory finisher were predicted using discrete element modelling (DEM) and compared to the measured values for spherical steel media. It was observed that the impact and bulk flow velocities were relatively insensitive to uncertainties in the contact coefficients of friction and restitution. It was concluded that the predicted impact and bulk flow velocities were dependent on the number of layers in the model. Consequently, the final DE model mimicked the key aspects of the experimental setup, including the submerged laser sensor. The DE method predictions of both impact velocity and bulk flow velocity were in reasonable agreement with the experimental measurements, with maximum differences of 20% and 30%, respectively. Discrete element modeling of granular flows is effective, but requires large numerical models. In an effort to reduce computational effort, this work presents a finite element (FE) continuum model of a vibrationally-fluidized granular flow. The constitutive equations governing the continuum model were calibrated using the discrete element method (DEM). The bulk flow behavior of the equivalent continuum media was then studied using both Lagrangian and Eulerian FE formulations. The bulk flow velocities predicted

  3. Vibrational optical activity

    International Nuclear Information System (INIS)

    Recent vibrational activity (VOA) research is discussed. The vibrational circular dichroism (VCD) experiments were carried out with a Fourier transform infrared spectrometer. One of the major anticipations from VOA spectroscopy is to be able to derive new pathways for determining the molecular structure. Shown is Fourier transform infrared absorption and VCD spectra of lyxopyranose in pyradine-d5 solvent. Raman optical activity measurements are discussed, and depolarized Raman and Raman optical activity spectra for (+)-alpha-pinene are presented. It was concluded that at present Raman optical activity can be measured in the entire vibrational spectral region, where as VCD has not been measured below 600 cm-1

  4. Identification of vibration excitations from acoustic measurements using near field acoustic holography and the force analysis technique

    Science.gov (United States)

    Pézerat, C.; Leclère, Q.; Totaro, N.; Pachebat, M.

    2009-10-01

    This study presents a method of using acoustic holography and the force analysis technique to identify vibration sources from radiated noise measurements. The structure studied is a plate excited by a shaker on which three measurements were performed: the first is a reference measurement of plate velocity obtained by scanning laser vibrometry, the second is based on sound pressure measurements in the near field of the structure, and the third is the measurement of normal acoustic velocities by using a p-U probe recently developed by Microflown Technologies. This was followed by the application of classical NAH, known as pressure-to-velocity holography and velocity-to-velocity holography to predict the plate velocity field from acoustic measurements at distances of 1 and 5 cm. Afterwards, the force analysis technique, also known as the RIFF technique, is applied with these five data sets. The principle is to inject the displacement field of the structure into its equation of motion and extract the resulting force distribution. This technique requires regularization done by a low-pass filter in the wavenumber domain. Apart from pressure-to-velocity holography at 5 cm, the reconstructed force distribution allows localizing the excitation point in the measurement area. FAT regularization is also shown to improve results as its cutoff wavenumber is optimized with the natural wavenumber of the plate. Lastly, quantitative force values are extracted from force distributions at all frequencies of the band 0-4 kHz studied and compared with the force spectrum measured directly by a piezoelectric sensor.

  5. Review on vibration transducers

    International Nuclear Information System (INIS)

    The vibrational behavior of a rotating machine at a certain rotational speed is carried out by a suitable non-contact transducer placed in precise selected position relative to the rotating machine. For the proper application of vibration measuring devices to the vibration parameters, these devices are classified with respect to the citation frequency and machine frequency. Sensors and transducers are categorized according to their applications. One variable can be converted into other by using electrical integrating or differentiating circuit. The differentiation accentuates the high frequency end of the spectrum while integration reduces the high frequency components. This paper presents different types of transducers, which can be used for vibration analysis purposes in rotating machinery. Factually sensors play an important role in the measurement of vibrations. Their characteristics are discussed and the sensitivity of mounting, installation and working principle is presented. The transduction mechanism has been discussed in a straightforward manner and comparison between different sensors and transduction is presented here. (author)

  6. Evaluation and Comparison of Methods for Measuring Ozone and NO2 Concentrations in Ambient Air during DISCOVER-AQ

    Science.gov (United States)

    Ambient evaluations of the various ozone and NO2 methods were conducted during field intensive studies as part of the NASA DISCOVER-AQ project conducted during July 2011 near Baltimore, MD; January – February 2013 in the San Juaquin valley, CA; September 2013 in Houston, TX...

  7. Measurement of the neutron spectrum and ambient neutron dose rate equivalent from the small 252Cf source at 1 meter

    Energy Technology Data Exchange (ETDEWEB)

    Radev, R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2015-07-07

    NASA Langley Research Center requested a measurement of the neutron spectral distribution and fluence from the 252Cf source (model NS-120, LLNL serial # 7001677, referred as the SMALL Cf source) and determination of the ambient neutron dose rate equivalent and kerma at 100 cm for the Radiation Budget Instrument Experiment (Rad-X). The dosimetric quantities should be based on the neutron spectrum and the current neutron-to-dose conversion coefficients.

  8. Natural vibration dynamics of Rainbow Bridge, Utah

    Science.gov (United States)

    Moore, J. R.; Thorne, M. S.; Wood, J. R.; Doyle, S.; Stanfield, E.; White, B.

    2015-12-01

    We measured resonant frequencies of Rainbow Bridge, Utah, one of the world's longest rock spans, during a field experiment recording ambient vibration data. Measurements were generated over 20 hours on March 23-24, 2015 using two broadband three-component seismometers placed on the bridge, and compared to concurrent data from nearby reference stations 20 and 220 m distant. We identified seven distinct modes of vibration for Rainbow Bridge between 1 and 6 Hz. Data for each resonant frequency was then analyzed to determine the frequency-dependent polarization vector in an attempt to clarify mode shapes; e.g. the fundamental mode represents out-of-plane horizontal flexure. We compared experimental data to results of 3D numerical modal analysis, using a new photogrammetric model of Rainbow Bridge generated in this study imported into COMSOL Multiphysics. Results compare well with measured data for seven of the first eight modeled modes, matching vibrational frequencies and polarization orientations generally within 10%. Only predicted mode 6 was not explicitly apparent in our experimental data. Large site-to-reference spectral ratios resolved from experimental data indicate high amplification on the bridge as compared to nearby bedrock.

  9. Ambient intelligence

    OpenAIRE

    Sanders, David; Gegov, Alexander

    2006-01-01

    This paper considers some history and the state of the art of Ambient Intelligence and from that seeks to identify new topics and future work. Ubiquitous computing, communications, human-centric computer interaction, embedded systems, context awareness, adaptive systems and distributed device networks are considered.

  10. Ambient intelligence

    CERN Document Server

    Weber, W; Aarts, E

    2005-01-01

    Addresses ambient intelligence used to support human contacts and accompany an individual''s path through the complicated modern world, from applications that are imminent, since they use essentially existing technologies, to ambitious ideas whose realization is still far away, due to major unsolved technical challenges.

  11. Ambient measurements of biological aerosol particles near Killarney, Ireland: a comparison between real-time fluorescence and microscopy techniques

    Directory of Open Access Journals (Sweden)

    D. A. Healy

    2014-02-01

    Full Text Available Primary biological aerosol particles (PBAP can contribute significantly to the coarse particle burden in many environments, may thus influence climate and precipitation systems as cloud nuclei, and can spread disease to humans, animals, and plants. Measurements of PBAP in natural environments taken at high time- and size- resolution are, however, sparse and so large uncertainties remain in the role that biological particles play in the Earth system. In this study two commercial real-time fluorescence particle sensors and a Sporewatch single-stage particle impactor were operated continuously from 2 August to 2 September 2010 at a rural sampling location in Killarney National Park in south western Ireland. A cascade impactor was operated periodically to collect size-resolved particles during exemplary periods. Here we report the first ambient comparison of the waveband integrated bioaerosol sensor (WIBS-4 with the ultraviolet aerodynamic particle sizer (UV-APS and also compare these real-time fluorescence techniques with results of fluorescence and optical microscopy of impacted samples. Both real-time instruments showed qualitatively similar behaviour, with increased fluorescent bioparticle concentrations at night when relative humidity was highest and temperature was lowest. The fluorescent particle number from the FL3 channel of the WIBS-4 and from the UV-APS were strongly correlated and dominated by a 3 μm mode in the particle size distribution. The WIBS FL2 channel exhibited particle modes at approx. 1 and 3 μm, and each were correlated with the concentration of fungal spores commonly observed in air samples collected at the site (ascospores, basidiospores, Ganoderma spp.. The WIBS FL1 channel exhibited variable multi-modal distributions turning into a broad featureless single mode after averaging and exhibited poor correlation with fungal spore concentrations, which may be due to the detection of bacterial and non-biological fluorescent

  12. Ambient measurements of biological aerosol particles near Killarney, Ireland: a comparison between real-time fluorescence and microscopy techniques

    Science.gov (United States)

    Healy, D. A.; Huffman, J. A.; O'Connor, D. J.; Pöhlker, C.; Pöschl, U.; Sodeau, J. R.

    2014-08-01

    Primary biological aerosol particles (PBAPs) can contribute significantly to the coarse particle burden in many environments. PBAPs can thus influence climate and precipitation systems as cloud nuclei and can spread disease to humans, animals, and plants. Measurement data and techniques for PBAPs in natural environments at high time- and size resolution are, however, sparse, and so large uncertainties remain in the role that biological particles play in the Earth system. In this study two commercial real-time fluorescence particle sensors and a Sporewatch single-stage particle impactor were operated continuously from 2 August to 2 September 2010 at a rural sampling location in Killarney National Park in southwestern Ireland. A cascade impactor was operated periodically to collect size-resolved particles during exemplary periods. Here we report the first ambient comparison of a waveband integrated bioaerosol sensor (WIBS-4) with a ultraviolet aerodynamic particle sizer (UV-APS) and also compare these real-time fluorescence techniques with results of fluorescence and optical microscopy of impacted samples. Both real-time instruments showed qualitatively similar behavior, with increased fluorescent bioparticle concentrations at night, when relative humidity was highest and temperature was lowest. The fluorescent particle number from the FL3 channel of the WIBS-4 and from the UV-APS were strongly correlated and dominated by a 3 μm mode in the particle size distribution. The WIBS FL2 channel exhibited particle modes at approx. 1 and 3 μm, and each was correlated with the concentration of fungal spores commonly observed in air samples collected at the site (ascospores, basidiospores, Ganoderma spp.). The WIBS FL1 channel exhibited variable multimodal distributions turning into a broad featureless single mode after averaging, and exhibited poor correlation with fungal spore concentrations, which may be due to the detection of bacterial and non-biological fluorescent

  13. Blade Vibration Measurement System for Characterization of Closely Spaced Modes and Mistuning Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The Phase I project successfully demonstrated that the advanced non-contacting stress measurement system (NSMS) was able to address closely spaced modes and...

  14. Real-time measurements of secondary organic aerosol formation and aging from ambient air in an oxidation flow reactor in the Los Angeles area

    Directory of Open Access Journals (Sweden)

    A. M. Ortega

    2015-08-01

    Full Text Available Field studies in polluted areas over the last decade have observed large formation of secondary organic aerosol (SOA that is often poorly captured by models. The study of SOA formation using ambient data is often confounded by the effects of advection, vertical mixing, emissions, and variable degrees of photochemical aging. An Oxidation Flow Reactor (OFR was deployed to study SOA formation in real-time during the CalNex campaign in Pasadena, CA, in 2010. A high-resolution aerosol mass spectrometer (AMS and a scanning mobility particle sizer (SMPS alternated sampling ambient and reactor-aged air. The reactor produced OH concentrations up to 4 orders of magnitude higher than in ambient air, achieving equivalent atmospheric aging from hours up to several weeks in 3 min of processing. OH radical concentration was continuously stepped, obtaining measurements of real-time SOA formation and oxidation at multiple equivalent ages from 0.8 days–6.4 weeks. Enhancement of OA from aging showed a maximum net SOA production between 0.8–6 days of aging with net OA mass loss beyond 2 weeks. Reactor SOA mass peaked at night, in the absence of ambient photochemistry, and correlated with trimethylbenzene concentrations. Reactor SOA formation was inversely correlated with ambient SOA and Ox, which along with the short-lived VOC correlation, indicates the importance of relatively reactive (τOH ∼ 0.3 day SOA precursors in the LA-Basin. Evolution of the elemental composition in the reactor was similar to trends observed in the atmosphere (O : C vs. H : C slope ∼ -0.65. Oxidation state of carbon (OSC in reactor SOA increased steeply with age and remained elevated (OSC ∼ 2 at the highest photochemical ages probed. The ratio of OA in the reactor output to excess CO (ΔCO, ambient CO above regional background vs. photochemical age is similar to previous studies at low to moderate ages and also extends to higher ages where OA loss dominates. The mass added at low

  15. Measurement of 3-D Vibrational Motion by Dynamic Photogrammetry Using Least-Square Image Matching for Sub-Pixel Targeting to Improve Accuracy.

    Science.gov (United States)

    Lee, Hyoseong; Rhee, Huinam; Oh, Jae Hong; Park, Jin Ho

    2016-01-01

    This paper deals with an improved methodology to measure three-dimensional dynamic displacements of a structure by digital close-range photogrammetry. A series of stereo images of a vibrating structure installed with targets are taken at specified intervals by using two daily-use cameras. A new methodology is proposed to accurately trace the spatial displacement of each target in three-dimensional space. This method combines the correlation and the least-square image matching so that the sub-pixel targeting can be obtained to increase the measurement accuracy. Collinearity and space resection theory are used to determine the interior and exterior orientation parameters. To verify the proposed method, experiments have been performed to measure displacements of a cantilevered beam excited by an electrodynamic shaker, which is vibrating in a complex configuration with mixed bending and torsional motions simultaneously with multiple frequencies. The results by the present method showed good agreement with the measurement by two laser displacement sensors. The proposed methodology only requires inexpensive daily-use cameras, and can remotely detect the dynamic displacement of a structure vibrating in a complex three-dimensional defection shape up to sub-pixel accuracy. It has abundant potential applications to various fields, e.g., remote vibration monitoring of an inaccessible or dangerous facility. PMID:26978366

  16. Application of DALYs in Measuring Health Effect of Ambient Air Pollution: A Case Study in Shanghai, China

    Institute of Scientific and Technical Information of China (English)

    YUN-HUI ZHANG; CHANG-HONG CHEN; GUO-HAI CHEN; GUI-XIANG SONG; BING-HENG CHEN; QING-YAN FU; HAI-DONG KAN

    2006-01-01

    To investigate the effect of ambient air pollution on human health and the subsequent disability-adjusted life years (DALYs) lost in Shanghai. Methods We used epidemiology-based exposure-response functions to calculate the attributable number of cases due to air pollution in Shanghai in 2000, and then we estimated the corresponding DALYs lost in Shanghai based on unit DALYs values of the health consequences. Results Ambient air pollution caused 103 064 DALYs lost in Shanghai in 2000. Among all the health endpoints, premature deaths and chronic bronchitis predominated in the value of total DALYs lost. Conclusion The air pollution levels have an adverse effect on the general population health and strengthen the rationale for limiting the levels of air pollution in outdoor air in Shanghai.

  17. Flexible Helicoids, Atomic Force Microscopy (AFM Cantilevers in High Mode Vibration, and Concave Notch Hinges in Precision Measurements and Research

    Directory of Open Access Journals (Sweden)

    Yakov Tseytlin

    2012-05-01

    Full Text Available Flexible structures are the main components in many precision measuring and research systems. They provide miniaturization, repeatability, minimal damping, low measuring forces, and very high resolution. This article focuses on the modeling, development, and comparison of three typical flexible micro- nano-structures: flexible helicoids, atomic force microscopy (AFM cantilevers, and concave notch hinges. Our theory yields results which allow us to increase the accuracy and functionality of these structures in new fields of application such as the modeling of helicoidal DNA molecules’ mechanics, the definition of instantaneous center of rotation in concave flexure notch hinges, and the estimation of the increase of spring constants and resolution at higher mode vibration in AFM cantilevers with an additional concentrated and end extended mass. We developed the original kinetostatic, reverse conformal mapping of approximating contours, and non-linear thermomechanical fluctuation methods for calculation, comparison, and research of the micromechanical structures. These methods simplify complicated solutions in micro elasticity but provide them with necessary accuracy. All our calculation results in this article and in all corresponding referenced author’s publications are in a good agreement with experimental and finite element modeling data within 10% or less.

  18. Vibrational power flow and structural intensity: Measurements and limitations at low frequencies

    DEFF Research Database (Denmark)

    Ohlrich, Mogens

    1991-01-01

    The cross-spectral methods and their sensitivity to phase errors are investigated for the two and four-accelerometer arrays. From experiments on a beam structure it is attempted to verify the influence of phase errors and to determine the usable frequency ranges of the two methods. Measurements are...

  19. Wind tunnel measurements of flow-induced vibration of a NACA0015 airfoil model

    Czech Academy of Sciences Publication Activity Database

    Šidlof, P.; Vlček, Václav; Štěpán, M.; Horáček, Jaromír; Luxa, Martin; Šimurda, David; Kozánek, Jan

    Anaheim: ASME, 2014, PVP2014-28294. ISBN 978-0-7918-4601-8. [ASME 2014 Pressure Vessels & Piping Conference. Anaheim, California (US), 20.07.2014-24.07.2014] R&D Projects: GA ČR GA13-10527S Institutional support: RVO:61388998 Keywords : aeroelasticity * flutter limit cycle oscillations (LCO) measurement * visualization of unsteady flow field Subject RIV: BI - Acoustics

  20. Turbocharger blade vibration: Measurement and validation through laser tip-timing

    OpenAIRE

    Allport, John; Jupp, Martyn

    2012-01-01

    High Cycle Fatigue (HCF) of turbine blades is a major cause of failure in turbochargers. In order to validate changes to blades intended to reduce fatigue failure, accurate measurement of blade dynamics is necessary. Strain gauging has limitations, so an alternative method is investigated. A description of the tip-timing method is given, applied to turbocharger testing. The advantages and disadvantages of laser probes are assessed. Examples of output data and interpretation are presented and ...

  1. The impact of vibrational Raman scattering of air on DOAS measurements of atmospheric trace gases

    OpenAIRE

    J. Lampel; Frieß, U.; Platt, U.

    2015-01-01

    In remote sensing applications, such as differential optical absorption spectroscopy (DOAS), atmospheric scattering processes need to be considered. After inelastic scattering on N2 and O2 molecules, the scattered photons occur as additional intensity at a different wavelength, effectively leading to "filling-in" of both solar Fraunhofer lines and absorptions of atmospheric constituents, if the inelastic scattering happens after the absorption. Measured spectra in p...

  2. The impact of vibrational Raman scattering of air on DOAS measurements of atmospheric trace gases

    OpenAIRE

    Lampel, J; Frieß, U.; U. Platt

    2015-01-01

    In remote sensing applications, such as differential optical absorption spectroscopy (DOAS), atmospheric scattering processes need to be considered. After inelastic scattering on N2 and O2 molecules, the scattered photons occur as additional intensity at a different wavelength, effectively leading to filling-in of both solar Fraunhofer lines and absorptions of atmospheric constituents. Measured spectra in passive DOAS applications are typically corrected for rotationa...

  3. Bias Errors in Measurement of Vibratory Power and Implication for Active Control of Structural Vibration

    DEFF Research Database (Denmark)

    Ohlrich, Mogens; Henriksen, Eigil; Laugesen, Søren

    1997-01-01

    Uncertainties in power measurements performed with piezoelectric accelerometers and force transducers are investigated. It is shown that the inherent structural damping of the transducers is responsible for a bias phase error, which typically is in the order of one degree. Fortunately, such bias...... errors can be largely compensated for by an absolute calibration of the transducers and inverse filtering that results in very small residual errors. Experimental results of this study indicate that these uncertainties will be in the order of one percent with respect to amplitude and two tenth of a...

  4. 3D Blade Vibration Measurements on an 80 m Diameter Wind Turbine by Using Non-contact Remote Measurement Systems

    Science.gov (United States)

    Ozbek, Muammer; Rixen, Daniel J.

    Non-contact optical measurement systems photogrammetry and laser interferometry are introduced as cost efficient alternatives to the conventional wind turbine/farm monitoring systems that are currently in use. The proposed techniques are proven to provide an accurate measurement of the dynamic behavior of a 2.5 MW—80 m diameter—wind turbine. Several measurements are taken on the test turbine by using 4 CCD cameras and 1 laser vibrometer and the response of the turbine is monitored from a distance of 220 m. The results of the infield tests and the corresponding analyses show that photogrammetry (also can be called as videogrammetry or computer vision technique) enable the 3D deformations of the rotor to be measured at 33 different points simultaneously with an average accuracy of ±25 mm, while the turbine is rotating. Several important turbine modes can also be extracted from the recorded data. Similarly, laser interferometry (used for the parked turbine only) provides very valuable information on the dynamic properties of the turbine structure. Twelve different turbine modes can be identified from the obtained response data.

  5. MARVEL: Measured active rotational-vibrational energy levels. II. Algorithmic improvements

    International Nuclear Information System (INIS)

    When determining energy levels from several, in cases many, measured and assigned high-resolution molecular spectra according to the Ritz principle, it is advantageous to investigate the spectra via the concept of spectroscopic networks (SNs). Experimental SNs are finite, weighted, undirected, multiedge, rooted graphs, whereby the vertices are the energy levels, the edges are the transitions, and the weights are provided by transition intensities. A considerable practical problem arises from the fact that SNs can be very large for isotopologues of molecules widely studied; for example, the experimental dataset for the H216O molecule contains some 160,000 measured transitions and 20,000 energy levels. In order to treat such large SNs and extract the maximum amount of information from them, sophisticated algorithms are needed when inverting the transition data. To achieve numerical effectiveness, we found the following efficient algorithms applicable to very large SNs: reading the input data employs hash codes, building the components of the SN utilizes a recursive depth-first search algorithm, solving the linear least-squares problem is via the conjugate gradient method, and determination of the uncertainties of the energy levels takes advantage of the robust reweighting algorithm.

  6. Vibration considerations in the design of the Advanced Photon Source at Argonne National Laboratory

    International Nuclear Information System (INIS)

    The Advanced Photon Source (APS), a new synchrotron radiation facility being built at Argonne National Laboratory, will provide the world's most brilliant X-ray beams for research in a wide range of technical fields. Successful operation of the APS requires an extremely stable positron closed orbit. Vibration of the storage ring quadrupole magnets, even in the submicron range, can lead to distortion of the positron closed orbit and to potentially unacceptable beam emittance growth, which results in degraded performance. This paper presents an overview of the technical approach used to minimize vibration response, beginning at the conceptual stage, through design and construction, and on to successful operation. Acceptance criteria relating to maximum allowable quadrupole magnet vibration are discussed. Soil properties are used to determine resonant frequencies of foundations and to predict attenuation characteristics. Two sources are considered to have the potential to excite the foundation: far-field sources, which are produced external to the facility, and near-field sources, which are produced within the facility. Measurements of ambient ground motion, monitored to determine far- field excitation, are presented. Ambient vibration was measured at several operating facilities within Argonne to gain insight on typical near-field excitation sources. Discussion covers the dynamic response characteristics of a prototypic magnet support structure to various excitations, including ambient floor motion, coolant flow, and magnet power. 19 refs., 10 figs., 5 tabs

  7. 地铁轨道减振措施的分析与探讨%Analysis and Research on Metro Vibration Mitigation Measures

    Institute of Scientific and Technical Information of China (English)

    潘炜; 刘晓华

    2015-01-01

    The principles of main measures taken by track traffic to decrease vibration were analyzed inclu-ding the steel spring floating slab track,type Ⅲ rail vibration absorber fastener,and vanguard fastener,and their actual damping effects were tested by field monitoring.The results showed that although three kinds of vibration damping measures could basically control the vibration induced by subway train within the standard limits,the abnormal rail corrugation phenomenon appears in the course,and there are some issues exist that the low fre-quency damping effect is poor,and the gap between theoretical and practical damping effect is present.%分析轨道交通采取的主要减振措施(钢弹簧浮置板道床、Ⅲ型减振器扣件和先锋扣件)的减振原理,并对其实际减振效果实地考察。结果表明,虽然3种减振措施基本可将地铁运行的振动控制在标准限值范围内,但在使用过程中出现钢轨异常波磨现象,还存在低频段减振效果差、理论与实际减振效果存在差距等问题。

  8. Identification of mistuning and model updating of an academic blisk based on geometry and vibration measurements

    Science.gov (United States)

    Nyssen, F.; Golinval, J.-C.

    2016-02-01

    In this work, an experimental modal analysis is performed on an academic bladed disk using a base excitation to identify the mistuning of each blade. Optical measurement is used to obtain the exact geometry of the structure and to be able to associate geometric mistuning to each blade. Differences are observed between the experimentally identified mistuning and the geometric mistuning. Since the bladed disk is a one-piece structure, there are no welded connections between the blades and the disk and the material properties can be assumed to be uniform. It can be shown that these differences come from non uniform clamping conditions, and that this mistuning is of the same order of magnitude than the variations in the geometry of the structure. It follows that the precise characterization of mistuning for industrial structures is in practice illusory because of the numerous factors introducing mistuning, such as the clamping conditions, aerodynamic damping, wear in service, etc.

  9. Simultaneous measurement of magnitude and phase in interferometric sum-frequency vibrational spectroscopy.

    Science.gov (United States)

    Covert, Paul A; FitzGerald, William R; Hore, Dennis K

    2012-07-01

    We present a visible-infrared sum-frequency spectroscopic technique that is capable of simultaneously determining the magnitude and phase of the sample response from a single set of experimental conditions. This is especially valuable in cases where the phase stability is high, as in collinear beam geometries, as it enables multiple experiments to be performed without re-measuring the local oscillator phase or the reference phase. After illustrating the phase stability achievable with such a geometry, we provide a technique for quantitatively determining the magnitude and phase from a single set of two-dimensional spectral-temporal interference fringes. A complete demonstration is provided for the C-H stretching frequency region at the surface of an octadecyltricholosilane film. PMID:22779640

  10. Measurements of Nitric-Oxide Nitrogen-Dioxide and Nitric Acid in Ambient and Captive Air by Second Harmonic Detection with Tunable Diode Lasers.

    Science.gov (United States)

    Iguchi, Toshio

    A Tropospheric Air Monitoring System (TAMS) was designed and constructed to measure trace gases in ambient air. The second harmonic component of the modulated light from a tunable diode laser due to an absorption line was measured to determine the mixing ratio of a trace gas in the sample. The technique of second harmonic detection increased the signal-to-noise ratio so that a species with mixing ratios in the sub-ppbv range could be detected. Second harmonic signals of an absorption line was calculated at different pressures (line shapes) and different modulation amplitudes to understand the optimum conditions for trace gas measurements. Also examined were the properties of the second harmonic signals due to etalon fringes, wavelength dependence of the laser power, tails of other absorption lines and interferences by these factors. The reduction of random noise by second harmonic detection was also investigated. The TAMS was intercalibrated with a chemiluminescence instrument of the University of Michigan. The system was transported to Los Angeles in fall of 1981 to join a captive air measurement programme. Both the captive and ambient air in Los Angeles was monitored for a one month period. The agreement with the University of Michigan was excellent for NO and satisfactory for NO(,2) and HNO(,3). The results of the intercalibrations and measurements are described.

  11. Picosecond CARS measurements of nitrogen vibrational loading and rotational/translational temperature in non-equilibrium discharges

    International Nuclear Information System (INIS)

    Picosecond coherent anti-Stokes Raman spectroscopy (CARS) is used to study vibrational energy loading and relaxation kinetics in nitrogen and air ns pulsed non-equilibrium plasmas, in both plane-to-plane and pin-to-pin geometries. In 10 kHz repetitively pulsed plane-to-plane plasmas, up to ∼50% of coupled discharge power is found to load vibrations, in good agreement with a master equation kinetic model. In the pin-to-pin geometry, ∼40% of total discharge energy in a single pulse in air at 100 Torr is found to couple directly to nitrogen vibrations by electron impact, also in good agreement with model predictions. Post-discharge, the total quanta in vibrational levels v = 0–9 is found to increase by ∼60% in air and by a factor of ∼3 in nitrogen, respectively, a result in direct contrast to modelling results which predict the total number of quanta to be essentially constant until ultimately decaying by V–T relaxation and mass diffusion. More detailed comparison between experiment and model show that the vibrational distribution function (VDF) predicted by the model during, and directly after, the discharge pulse is in good agreement with that determined experimentally. However, for time delays exceeding ∼1 µs, the experimental VDF shows populations of vibrational levels v ⩾ 2 greatly exceeding modelling results, which predict their predominant decay due to net downward V–V transfer and corresponding increase in v = 1 population. This is at variance with the experimental results, which show a significant monotonic increase in the populations of levels v = 2–9 at t ∼ 1–10 µs after the discharge pulse, both in nitrogen and air, before gradually switching to relaxation at t ∼ 10–100 µs. It is concluded that a collisional process is likely feeding high vibrational levels at a rate which is comparable to the rate at which population of the high levels is lost due to net downward V–V energy transfer. A likely candidate for

  12. Ambient intelligence

    CERN Document Server

    Basten, Twan; de Groot, Harmke

    2007-01-01

    ""This book is truly an eye-opener as it is the first book that relates the dream scenarios of Ambient Intelligence quantitatively to the technical challenges and requirements of the huge distributed and interoperable embedded systems needed to implement AmI systems in the real world. This book is strongly recommended to a wide spectrum of engineers interested to embark in this rapidly emerging and fascinating technology."" (From the foreword by Hugo De Man, Professor K.U. Leuven and Senior Research Fellow IMEC)

  13. Historical Ambient Air Quality Data Inventory

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Historical Ambient Air Quality Data Inventory contains measured and estimated data on ambient air pollution for use in assessing air quality, assisting in...

  14. Ship Vibrations

    DEFF Research Database (Denmark)

    Sørensen, Herman

    1997-01-01

    Methods for calculating natural frequencies for ship hulls and for plates and panels.Evaluation of the risk for inconvenient vibrations on board......Methods for calculating natural frequencies for ship hulls and for plates and panels.Evaluation of the risk for inconvenient vibrations on board...

  15. Animal Communications Through Seismic Vibrations

    Energy Technology Data Exchange (ETDEWEB)

    Hill, Peggy (University of Tulsa)

    2001-05-02

    Substrate vibration has been important to animals as a channel of communication for millions of years, but our literature on vibration in this context of biologically relevant information is only decades old. The jaw mechanism of the earliest land vertebrates allowed them to perceive substrate vibrations as their heads lay on the ground long before airborne sounds could be heard. Although the exact mechanism of vibration production and the precise nature of the wave produced are not always understood, recent development of affordable instrumentation to detect and measure vibrations has allowed researchers to answer increasingly sophisticated questions about how animals send and receive vibration signals. We now know that vibration provides information used in predator defense, prey detection, recruitment to food, mate choice, intrasexual competition, and maternal/brood social interactions in a variety of insect orders, spiders, crabs, scorpions, chameleons, frogs, golden moles, mole rats, kangaroos rats, wallabies, elephants and bison.

  16. On the impact of Vibrational Raman Scattering of N2/O2 on MAX-DOAS Measurements of atmospheric trace gases

    Science.gov (United States)

    Lampel, Johannes; Zielcke, Johannes; Frieß, Udo; Platt, Ulrich; Wagner, Thomas

    2015-04-01

    In remote sensing applications, such as the applications of differential optical absorption spectroscopy (DOAS), atmospheric scattering processes need to be considered since they can modify the observed spectra. Inelastic scattering of photons by N2 and O2 molecules can be observed as additional intensity, effectively leading to filling-in of both, solar Fraunhofer lines and absorption bands of atmospheric constituents. The main contribution is due to rotational Raman scattering, which can lead to changes in observed optical densities of absorption lines up to several percent. Measured optical densities are typically corrected for this effect (also known as Ring Effect). In contrast to that Vibrational Raman scattering of N2 and O2 was often thought to be negligible, but also contributes to this effect. We present calculations of Vibrational Raman cross-sections for O2 and N2 for the application in passive DOAS measurements. Consequences of vibrational Raman scattering are red-shifted Fraunhofer structures, so called 'Fraunhofer Ghost' lines (FGL), in scattered light spectra and filling-in of Fraunhofer lines, additional to rotational Raman scattering. We also present first unequivocal observations of FGL at optical densities of up to several 104. From our measurements and calculations of the optical density of these FGL, we conclude, that this phenomenon has to be included in the spectral evaluation of weak absorbers. Its relevance is demonstrated in spectral evaluations of Multi-Axis (MAX)-DOAS data and an agreement with calculated scattering cross-sections is found. To exclude cross-sensitivities with other absorbers, such as water vapour, MAX-DOAS data from different latitudes and different instruments were analysed. We evaluate the influence of the additional intensities due to vibrational Raman scattering on the spectral retrieval of IO, Glyoxal, H2O and NO2 in the blue wavelength range. In the case of NO2 the column densities derived from certain wavelength

  17. Obtaining and Estimating Low Noise Floors in Vibration Sensors

    DEFF Research Database (Denmark)

    Brincker, Rune; Larsen, Jesper Abildgaard

    2007-01-01

    For some applications like seismic applications and measuring ambient vibrations in structures, it is essential that the noise floors of the sensors and other system components are low and known to the user. Some of the most important noise sources are reviewed and it is discussed how the sensor...... can be designed in order to obtain a low noise floor. Techniques to estimate the noise floors for sensors are reviewed and are demonstrated on a commercial commonly used sensor for vibration testing. It is illustrated how the noise floor can be calculated using the coherence between simultaneous...... measurements on two channels, and it is illustrated how the singular values decomposition can be used for estimating noise floors and signals in multi-channel applications....

  18. Ambient measurements of aromatic and oxidized VOCs by PTR-MS and GC-MS: intercomparison between four instruments in a boreal forest in Finland

    Directory of Open Access Journals (Sweden)

    M. K. Kajos

    2015-04-01

    Full Text Available Proton transfer reaction mass spectrometry (PTR-MS and gas chromatography mass spectrometry GC-MS allow real-time measurements of various atmospheric volatile organic compounds (VOC. By taking parallel measurements in ambient conditions, two PTR-MSs and two GC-MSs were studied for their ability to measure methanol, acetaldehyde, acetone, benzene and toluene. The measurements were conducted at a rural boreal forest site in southern Finland between 13 April and 14 May 2012. This paper presents correlations and possible biases between the concentrations measured using the four instruments. This paper presents correlations and possible biases between the concentrations measured using the four instruments. A very good correlation was found for benzene and acetone measurements between all instruments (the mean R value was 0.88 for both compounds, while for acetaldehyde and toluene the correlation was weaker (with a mean R value of 0.50 and 0.62, respectively. For some compounds, notably for methane, there were considerable systematic differences in the mixing ratios measured by the different instruments, despite the very good correlation between the instruments (mean R = 0.90. The systematic difference arises as a difference in the linear regression slope between measurements conducted between instruments, rather than as an offset. This mismatch indicates that the systematic uncertainty in the sensitivity of a given instrument can lead to an uncertainty of 50–100% in the methanol emissions measured by commonly used methods.

  19. Ambient measurements of aromatic and oxidized VOCs by PTR-MS and GC-MS: intercomparison between four instruments in a boreal forest in Finland

    Science.gov (United States)

    Kajos, M. K.; Rantala, P.; Hill, M.; Hellén, H.; Aalto, J.; Patokoski, J.; Taipale, R.; Hoerger, C. C.; Reimann, S.; Ruuskanen, T. M.; Rinne, J.; Petäjä, T.

    2015-04-01

    Proton transfer reaction mass spectrometry (PTR-MS) and gas chromatography mass spectrometry GC-MS) allow real-time measurements of various atmospheric volatile organic compounds (VOC). By taking parallel measurements in ambient conditions, two PTR-MSs and two GC-MSs were studied for their ability to measure methanol, acetaldehyde, acetone, benzene and toluene. The measurements were conducted at a rural boreal forest site in southern Finland between 13 April and 14 May 2012. This paper presents correlations and possible biases between the concentrations measured using the four instruments. This paper presents correlations and possible biases between the concentrations measured using the four instruments. A very good correlation was found for benzene and acetone measurements between all instruments (the mean R value was 0.88 for both compounds), while for acetaldehyde and toluene the correlation was weaker (with a mean R value of 0.50 and 0.62, respectively). For some compounds, notably for methane, there were considerable systematic differences in the mixing ratios measured by the different instruments, despite the very good correlation between the instruments (mean R = 0.90). The systematic difference arises as a difference in the linear regression slope between measurements conducted between instruments, rather than as an offset. This mismatch indicates that the systematic uncertainty in the sensitivity of a given instrument can lead to an uncertainty of 50-100% in the methanol emissions measured by commonly used methods.

  20. Active Pneumatic Vibration Control by Using Pressure and Velocity Measurements and Adaptive Fuzzy Sliding-Mode Controller

    Directory of Open Access Journals (Sweden)

    Jia-Wei Wu

    2013-07-01

    Full Text Available This paper presents an intelligent control strategy to overcome nonlinear and time-varying characteristics of a diaphragm-type pneumatic vibration isolator (PVI system. By combining an adaptive rule with fuzzy and sliding-mode control, the method has online learning ability when it faces the system’s nonlinear and time-varying behaviors during an active vibration control process. Since the proposed scheme has a simple structure, it is easy to implement. To validate the proposed scheme, a composite control which adopts both chamber pressure and payload velocity as feedback signal is implemented. During experimental investigations, sinusoidal excitation at resonance and random-like signal are input on a floor base to simulate ground vibration. Performances obtained from the proposed scheme are compared with those obtained from passive system and PID scheme to illustrate the effectiveness of the proposed intelligent control.

  1. 新型振动样品磁强计测量材料磁性%Material magnetic properties measured by new vibrating sample magnetometer

    Institute of Scientific and Technical Information of China (English)

    郇维亮; 高峰; 徐小龙

    2012-01-01

    简述新型振动样品磁强计测量原理,介绍自制的采用电动机驱动的振动样品磁强计,并通过用已知饱和磁矩的镍球对仪器进行定标,分别测量了铁氧体多晶小球和普通小钢球的磁化曲线,取得理想的实验结果.自制新型振动样品磁强计具有测量信号大和能判定磁矩方向的特点,该仪器可应用于高校近代物理实 验的教学.%This paper introduceds the measuring principle of a new type vibrating sample magnetometer and the home-made motor-driven vibrating sample magnetometer, and the magnetometer has been calibrated by the known saturation magnetic moment nickel ball and measured the magnetization curves of polycrystalline ferrite small ball and ordinary one respectively, and ideal experimental results are obtained. The home-made vibrating sample magnetometer with the characteristics of large measurement signal can detect the direction of magnetic moment, and the instrument can be used to modern physics experiments teaching in colleges and universities.

  2. Vibration energy harvester optimization using artificial intelligence

    Science.gov (United States)

    Hadas, Z.; Ondrusek, C.; Kurfurst, J.; Singule, V.

    2011-06-01

    This paper deals with an optimization study of a vibration energy harvester. This harvester can be used as autonomous source of electrical energy for remote or wireless applications, which are placed in environment excited by ambient mechanical vibrations. The ambient energy of vibrations is usually on very low level but the harvester can be used as alternative source of energy for electronic devices with an expected low level of power consumption of several mW. The optimized design of the vibration energy harvester was based on previous development and the sensitivity of harvester design was improved for effective harvesting from mechanical vibrations in aeronautic applications. The vibration energy harvester is a mechatronic system which generates electrical energy from ambient vibrations due to precision tuning up generator parameters. The optimization study for maximization of harvested power or minimization of volume and weight are the main goals of our development. The optimization study of such complex device is complicated therefore artificial intelligence methods can be used for tuning up optimal harvester parameters.

  3. Self-powered autonomous wireless sensor node using vibration energy harvesting

    OpenAIRE

    Torah, Russel; Glynne-Jones, Peter; Tudor, John; O'Donnell, T.; Roy, S.; Beeby, Steve

    2008-01-01

    This paper reports the development and implementation of an energy aware autonomous wireless condition monitoring sensor system (ACMS) powered by ambient vibrations. An electromagnetic (EM) generator has been designed to harvest sufficient energy to power a radio-frequency (RF) linked accelerometer-based sensor system. The ACMS is energy aware and will adjust the measurement/transmit duty cycle according to the available energy; this is typically every 3 s at 0.6 m s?2 rms acceleration and ca...

  4. Vibration sensor

    International Nuclear Information System (INIS)

    This invention relates to a sensor for detecting the vibrations of a liquid, specifically designed for detecting low frequency vibrations transmitted by a high temperature liquid, particularly the liquid metal coolant of a fast reactor. It comprises a piezoelectric transducer inside a cavity closed by a membrane in contact with the liquid and in which a vacuum is made. The membrane is connected to one of the sides of the transducer, called the first side, through a mechanical vibration transmitting part made of a thermal insulation material. The other side of the transducer, termed second side, is blocked and the cavity has at least one leak-tight passage for an electric conductor

  5. Evaluation of innovative air-monitoring technologies for the measurement of ambient concentrations of ozone and its precursors at the 1996 Summer Olympics

    Science.gov (United States)

    Gamiles, Donald S.; Rodgers, Michael; Meeker, Charles; Olive, Brent S.; Simpson, Orman A.

    1997-05-01

    An open path Fourier transform IR spectrometer and an ultra- violet differential optical absorption spectrometer were used during the 1996 Atlanta Olympics games to monitor for ambient ozone and its precursors near the Olympic Village. Both systems were operated continuously before, during, and after the increase in Atlanta's population associated with the Summer games. The study utilized the massive changes in population patterns to observe and measure changes in local air quality due to an increased local population. A second goal of the program was to evaluate both open path instruments in continuous field use over a period of several weeks. The evaluation included the following criteria: instrumentation operability, system precision and accuracy, detection capability, and over-all ease of use. Both open path systems selected and measured ambient levels of ozone. A limited number of ozone precursors were detected. The study was sponsored by the Georgia Institute of Technology's Air Quality Laboratory, the US Department of Energy, and the US Environmental Protection Agency.

  6. A system for ocean ambient noise measurement based on subsurface buoy%基于潜标的海洋环境噪声测量系统

    Institute of Scientific and Technical Information of China (English)

    吕云飞; 张殿伦; 邹吉武; 兰华林; 孙大军

    2009-01-01

    This paper aims to design the system of ocean ambient noise measurement, the system is deployed with subsurface buoy, low frequency ambient noise of shallow water is measured by vector hydrophone. Vector hydrophone measures pressure and all three orthogonal components of particle velocity at a single point in space,the measured signal is preprocessed and sampled, the sampled data can be self-stored in subsurface buoy or transmitted to shore station by buoy. The method of noise measurement is discussed, the results of the sea trials show that the system is feasible and reliable.%对海洋环境噪声测量系统技术进行了研究,设计和实现了一种基于潜标的海洋环境噪声测量系统,并进行了海上试验.该系统采用潜标的布放方式,利用矢量水听器测量浅海海洋环境噪声场的低频噪声.矢量水听器同步测量声场空间一点处的声压和质点振速三个正交分量, 测量信号经预处理后,对信号进行数模变换,得到的噪声数据可以在潜标中自记录或通过水面浮标传输到岸站存储.对噪声测量方法进行的分析和海上试验的结果表明,该系统稳定可靠,能正确地拾取海洋环境噪声.

  7. Numerical Investigation of the Effects of Wind Tunnel Model Vibrations on the Measured Aerodynamic Properties of Airfoils and Wings

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    This paper presents a numerical prediction of the unsteady flow field around oscillating airfoils at high angles of attack by solving unsteady Reynolds-averaged Navier-Stokes equations with SST turbulence model in order to simulate the effects of wind tunnel model vibrations on the aerodynamic properties of airfoils,especially high-aspect-ratio wings in a wind tunnel.The effects of the phase lagging between different modes of oscillations,i.e.,the airfoil plunging oscillation mode,the pitching oscillation mode,and the forward-backward oscillation mode,are also studied.It is shown that the vibrations (oscillations) of airfoils can cause the unsteady shedding of large-size separated vortex to precede the stationary stall incidence,hence lead to a stall onset at some earlier (lower) incidence than that in the steady sense.The different phase lagging has different effect on the flow field.When the pitching oscillation mode has small phase lagging behind the plunging oscillation mode,the effect of vibrations is large.Besides,if the amplitude of the oscillations is large enough,and the different modes of vibrations match or combine appropriately,the unsteady stall may occur 2° earlier in angle of attack than the case where airfoils keep stationary.

  8. Development, implementation, and characterization of a standalone embedded viscosity measurement system based on the impedance spectroscopy of a vibrating wire sensor

    Science.gov (United States)

    Santos, José; Janeiro, Fernando M.; Ramos, Pedro M.

    2015-10-01

    This paper presents an embedded liquid viscosity measurement system based on a vibrating wire sensor. Although multiple viscometers based on different working principles are commercially available, there is still a market demand for a dedicated measurement system capable of performing accurate, fast measurements and requiring little or no operator training for simple systems and solution monitoring. The developed embedded system is based on a vibrating wire sensor that works by measuring the impedance response of the sensor, which depends on the viscosity and density of the liquid in which the sensor is immersed. The core of the embedded system is a digital signal processor (DSP) which controls the waveform generation and acquisitions for the measurement of the impedance frequency response. The DSP also processes the acquired waveforms and estimates the liquid viscosity. The user can interact with the measurement system through a keypad and an LCD or through a computer with a USB connection for data logging and processing. The presented system is tested on a set of viscosity standards and the estimated values are compared with the standard manufacturer specified viscosity values. A stability study of the measurement system is also performed.

  9. Development, implementation, and characterization of a standalone embedded viscosity measurement system based on the impedance spectroscopy of a vibrating wire sensor

    International Nuclear Information System (INIS)

    This paper presents an embedded liquid viscosity measurement system based on a vibrating wire sensor. Although multiple viscometers based on different working principles are commercially available, there is still a market demand for a dedicated measurement system capable of performing accurate, fast measurements and requiring little or no operator training for simple systems and solution monitoring. The developed embedded system is based on a vibrating wire sensor that works by measuring the impedance response of the sensor, which depends on the viscosity and density of the liquid in which the sensor is immersed. The core of the embedded system is a digital signal processor (DSP) which controls the waveform generation and acquisitions for the measurement of the impedance frequency response. The DSP also processes the acquired waveforms and estimates the liquid viscosity. The user can interact with the measurement system through a keypad and an LCD or through a computer with a USB connection for data logging and processing. The presented system is tested on a set of viscosity standards and the estimated values are compared with the standard manufacturer specified viscosity values. A stability study of the measurement system is also performed. (paper)

  10. Vibration Compensation for Scanning Tunneling Microscope

    Institute of Scientific and Technical Information of China (English)

    LI Meng-chao; FU Xing; WEI Xiao-lei; HU Xiao-tang

    2003-01-01

    The influence of vibration is already one of main obstacles for improving the nano measuring accuracy.The techniques of anti-vibration,vibration isolation and vibration compensation become an important branch in nano measuring field.Starting with the research of sensitivity to vibration of scanning tunneling microscope(STM),the theory,techniques and realization methods of nano vibration sensor based on tunnel effect are initially investigated,followed by developing the experimental devices.The experiments of the vibration detection and vibration compensation are carried out.The experimental results show that vibration sensor based on tunnel effect is characterized by high sensitivity,good frequency characteristic and the same vibratory response characteristic consistent with STM.

  11. Air Pollution and Preterm Birth in the U.S. State of Georgia (2002–2006): Associations with Concentrations of 11 Ambient Air Pollutants Estimated by Combining Community Multiscale Air Quality Model (CMAQ) Simulations with Stationary Monitor Measurements

    OpenAIRE

    Hao, Hua; Chang, Howard H.; Holmes, Heather A.; Mulholland, James A.; Klein, Mitch; Darrow, Lyndsey A.; Strickland, Matthew J

    2015-01-01

    Background: Previous epidemiologic studies suggest associations between preterm birth and ambient air pollution. Objective: We investigated associations between 11 ambient air pollutants, estimated by combining Community Multiscale Air Quality model (CMAQ) simulations with measurements from stationary monitors, and risk of preterm birth (< 37 weeks of gestation) in the U.S. state of Georgia. Methods: Birth records for singleton births ≥ 27 weeks of gestation with complete covariate informatio...

  12. A new high-transmission inlet for the Caltech nano-RDMA for size distribution measurements of sub-3 nm ions at ambient concentrations

    Science.gov (United States)

    Franchin, Alessandro; Downard, Andy; Kangasluoma, Juha; Nieminen, Tuomo; Lehtipalo, Katrianne; Steiner, Gerhard; Manninen, Hanna E.; Petäjä, Tuukka; Flagan, Richard C.; Kulmala, Markku

    2016-06-01

    Reliable and reproducible measurements of atmospheric aerosol particle number size distributions below 10 nm require optimized classification instruments with high particle transmission efficiency. Almost all differential mobility analyzers (DMAs) have an unfavorable potential gradient at the outlet (e.g., long column, Vienna type) or at the inlet (nano-radial DMA), preventing them from achieving a good transmission efficiency for the smallest nanoparticles. We developed a new high-transmission inlet for the Caltech nano-radial DMA (nRDMA) that increases the transmission efficiency to 12 % for ions as small as 1.3 nm in Millikan-Fuchs mobility equivalent diameter, Dp (corresponding to 1.2 × 10-4 m2 V-1 s-1 in electrical mobility). We successfully deployed the nRDMA, equipped with the new inlet, in chamber measurements, using a particle size magnifier (PSM) and as a booster a condensation particle counter (CPC). With this setup, we were able to measure size distributions of ions within a mobility range from 1.2 × 10-4 to 5.8 × 10-6 m2 V-1 s-1. The system was modeled, tested in the laboratory and used to measure negative ions at ambient concentrations in the CLOUD (Cosmics Leaving Outdoor Droplets) 7 measurement campaign at CERN. We achieved a higher size resolution (R = 5.5 at Dp = 1.47 nm) than techniques currently used in field measurements (e.g., Neutral cluster and Air Ion Spectrometer (NAIS), which has a R ˜ 2 at largest sizes, and R ˜ 1.8 at Dp = 1.5 nm) and maintained a good total transmission efficiency (6.3 % at Dp = 1.5 nm) at moderate inlet and sheath airflows (2.5 and 30 L min-1, respectively). In this paper, by measuring size distributions at high size resolution down to 1.3 nm, we extend the limit of the current technology. The current setup is limited to ion measurements. However, we envision that future research focused on the charging mechanisms could extend the technique to measure neutral aerosol particles as well, so that it will be possible

  13. A comparison of measured and calculated neutron inelastic scattering cross sections for vibrational states from 680 to 1060 keV in 238U

    International Nuclear Information System (INIS)

    Measured and calculated data are presented on neutron inelastic scattering cross sections for vibrational states from 680 to 1060 keV in 238U. Time-of-flight measurements were made at the University of Lowell, Massachusettes, (U.S.A.) using incident neutrons up to 2.2 MeV, and are compared with theoretical calculations carried out at the Los Alamos National Laboratory (U.S.A.). The paper was given at the International Conference on 'Nuclear data for basic and applied science', Santa Fe, (U.S.A.) 1985. (UK)

  14. Development of a phase-sensitive Fourier domain optical coherence tomography system to measure mouse organ of Corti vibrations in two cochlear turns

    International Nuclear Information System (INIS)

    In this study, we have developed a phase-sensitive Fourier-domain optical coherence tomography system to simultaneously measure the in vivo inner ear vibrations in the hook area and second turn of the mouse cochlea. This technical development will enable measurement of intra-cochlear distortion products at ideal locations such as the distortion product generation site and reflection site. This information is necessary to un-mix the complex mixture of intra-cochlear waves comprising the DPOAE and thus leads to the non-invasive identification of the local region of cochlear damage

  15. Development of a phase-sensitive Fourier domain optical coherence tomography system to measure mouse organ of Corti vibrations in two cochlear turns

    Science.gov (United States)

    Ramamoorthy, Sripriya; Zhang, Yuan; Petrie, Tracy; Jacques, Steven; Wang, Ruikang; Nuttall, Alfred L.

    2015-12-01

    In this study, we have developed a phase-sensitive Fourier-domain optical coherence tomography system to simultaneously measure the in vivo inner ear vibrations in the hook area and second turn of the mouse cochlea. This technical development will enable measurement of intra-cochlear distortion products at ideal locations such as the distortion product generation site and reflection site. This information is necessary to un-mix the complex mixture of intra-cochlear waves comprising the DPOAE and thus leads to the non-invasive identification of the local region of cochlear damage.

  16. Development of a phase-sensitive Fourier domain optical coherence tomography system to measure mouse organ of Corti vibrations in two cochlear turns

    Energy Technology Data Exchange (ETDEWEB)

    Ramamoorthy, Sripriya [Oregon Hearing Research Center, Oregon Health & Science University, Portland, Oregon (United States); Zhang, Yuan; Jacques, Steven [Department of Biomedical Engineering, Oregon Health & Science University, Portland, Oregon (United States); Petrie, Tracy; Wang, Ruikang [Department of Bioengineering, University of Washington, Seattle, Washington (United States); Nuttall, Alfred L. [Oregon Hearing Research Center, Oregon Health & Science University, Portland, Oregon (United States); Kresge Hearing Research Institute, The University of Michigan, Ann Arbor, Michigan (United States)

    2015-12-31

    In this study, we have developed a phase-sensitive Fourier-domain optical coherence tomography system to simultaneously measure the in vivo inner ear vibrations in the hook area and second turn of the mouse cochlea. This technical development will enable measurement of intra-cochlear distortion products at ideal locations such as the distortion product generation site and reflection site. This information is necessary to un-mix the complex mixture of intra-cochlear waves comprising the DPOAE and thus leads to the non-invasive identification of the local region of cochlear damage.

  17. The multi-axis vibration environment and man.

    Science.gov (United States)

    Lovesey, E J

    1970-12-01

    Many investigations into the effects of vibration on man have been performed since Mallock's first study of London Underground vibrations in 1902. The vibration research has tended to be confined to the vertical (heave) axis, yet recent experiments have indicated that low frequency vibration along the lateral (sway) axis has a greater adverse effect upon comfort and performance. Measurements of the vibration environments in current forms of transport including motor vehicles, hovercraft and aircraft etc have shown that appreciable quantities of vibration along all three axes exist. Further vibration research should consider the effects of multi-axis vibrations upon man rather than limit tests to single axis vibration. PMID:15676336

  18. Random Vibrations

    Science.gov (United States)

    Messaro. Semma; Harrison, Phillip

    2010-01-01

    Ares I Zonal Random vibration environments due to acoustic impingement and combustion processes are develop for liftoff, ascent and reentry. Random Vibration test criteria for Ares I Upper Stage pyrotechnic components are developed by enveloping the applicable zonal environments where each component is located. Random vibration tests will be conducted to assure that these components will survive and function appropriately after exposure to the expected vibration environments. Methodology: Random Vibration test criteria for Ares I Upper Stage pyrotechnic components were desired that would envelope all the applicable environments where each component was located. Applicable Ares I Vehicle drawings and design information needed to be assessed to determine the location(s) for each component on the Ares I Upper Stage. Design and test criteria needed to be developed by plotting and enveloping the applicable environments using Microsoft Excel Spreadsheet Software and documenting them in a report Using Microsoft Word Processing Software. Conclusion: Random vibration liftoff, ascent, and green run design & test criteria for the Upper Stage Pyrotechnic Components were developed by using Microsoft Excel to envelope zonal environments applicable to each component. Results were transferred from Excel into a report using Microsoft Word. After the report is reviewed and edited by my mentor it will be submitted for publication as an attachment to a memorandum. Pyrotechnic component designers will extract criteria from my report for incorporation into the design and test specifications for components. Eventually the hardware will be tested to the environments I developed to assure that the components will survive and function appropriately after exposure to the expected vibration environments.

  19. Ambient dose equivalent measurements in secondary radiation fields at proton therapy facility CCB IFJ PAN in Krakow using recombination chambers

    Directory of Open Access Journals (Sweden)

    Jakubowska Edyta A.

    2016-03-01

    Full Text Available This work presents recombination methods used for secondary radiation measurements at the Facility for Proton Radiotherapy of Eye Cancer at the Institute for Nuclear Physics, IFJ, in Krakow (Poland. The measurements of H*(10 were performed, with REM-2 tissue equivalent chamber in two halls of cyclotrons AIC-144 and Proteus C-235 and in the corridors close to treatment rooms. The measurements were completed by determination of gamma radiation component, using a hydrogen-free recombination chamber. The results were compared with the measurements using rem meter types FHT 762 (WENDI-II and NM2 FHT 192 gamma probe and with stationary dosimetric system.

  20. On dithiothreitol (DTT as a measure of oxidative potential for ambient particles: evidence for the importance of soluble ewline transition metals

    Directory of Open Access Journals (Sweden)

    J. G. Charrier

    2012-10-01

    Full Text Available The rate of consumption of dithiothreitol (DTT is increasingly used to measure the oxidative potential of particulate matter (PM, which has been linked to the adverse health effects of PM. While several quinones are known to be very reactive in the DTT assay, it is unclear what other chemical species might contribute to the loss of DTT in PM extracts. To address this question, we quantify the rate of DTT loss from individual redox-active species that are common in ambient particulate matter. While most past research has indicated that the DTT assay is not sensitive to metals, our results show that seven out of the ten transition metals tested do oxidize DTT, as do three out of the five quinones tested. While metals are less efficient at oxidizing DTT compared to the most reactive quinones, concentrations of soluble transition metals in fine particulate matter are generally much higher than those of quinones. The net result is that metals appear to dominate the DTT response for typical ambient PM2.5 samples. Based on particulate concentrations of quinones and soluble metals from the literature, and our measured DTT responses for these species, we estimate that for typical PM2.5 samples approximately 80% of DTT loss is from transition metals (especially copper and manganese, while quinones account for approximately 20%. We find a similar result for DTT loss measured in a small set of PM2.5 samples from the San Joaquin Valley of California. Because of the important contribution from metals, we also tested how the DTT assay is affected by EDTA, a chelator that is sometimes used in the assay. EDTA significantly suppresses the response from both metals and quinones; we therefore recommend that EDTA should not be included in the DTT assay.

  1. Aircraft crew radiation workplaces: Comparison of measured and calculated ambient dose equivalent rate data using the EURADOS in-flight radiation data base

    International Nuclear Information System (INIS)

    In May 2000, the chairman of the European Radiation Dosimetry Group (EURADOS) invited a number of experts with experience of cosmic radiation dosimetry to form a working group (WG 5) on aircraft crew dosimetry. Three observers from the Article 31 Group of Experts as well as one observer from the Joint Aviation Authorities (JAA) were also appointed. The European Commission funded the meetings. Full meetings were organised in January 2001 and in November 2001. An editorial group, who are the authors of this publication, started late in 2002 to finalise a draft report, which was submitted to the Article 31 Group of Experts in June 2003. The methods and data reported are the product of the work of 26 research institutes from the EU, USA and Canada. Some of the work was supported by contracts with the European Commission, Directorate General XII, Science, Research and Development. A first overview of the EC report was published late in 2004. In this publication we focus on a comparison of measured and calculated ambient dose rate data using the EURADOS In-Flight Data Base. The evaluation of results obtained by different methods and groups, and comparison of measurement results and the results of calculations were performed in terms of the operational quantity ambient dose equivalent, H*(10). Aspects of measurement uncertainty are reported also. The paper discusses the estimation of annual doses for given flight hours and gives an outline of further research needed in the field of aircraft crew dosimetry, such as the influence of solar particle events. (authors)

  2. Vibrational relaxation in pyridine upon supersonic expansion

    Science.gov (United States)

    Maris, Assimo; Favero, Laura B.; Danieli, Roberto; Favero, Paolo G.; Caminati, Walther

    2000-11-01

    The rotational spectra of five vibrational states of pyridine have been assigned and measured by millimeter wave absorption spectroscopy in a supersonic expansion. The intensities of the lines of the vibrational satellites with respect to the ground state after the supersonic expansion depend on the kind of carrier gas, backing pressure, pyridine concentration, and symmetry of the rotational and vibrational states. Several rotational transitions of the vibrational satellites have also been measured in a conventional cell to complete the spectral assignment.

  3. Study of the vibrations induced by two-phase flow in steam generator: measurement of void fraction in a two-phase flow

    International Nuclear Information System (INIS)

    Two-phase flow can trigger vibration phenomena that are not well predicted by models like the homogeneous model. Concerning the steam generator of a Candu type reactor, these vibrations may lead to the failure of tubes. The coupling between thermo-hydraulic and vibration phenomena requires models that treat sliding between liquid and vapor phases. The purpose of this work is to study a series of experiments performed in a freon loop. These experiments simulate a two-phase flow through a bundle of tubes. Most estimations of vibratory parameters are based on the assumption of a uniform distribution of the void fraction. An optic probe has been used to measure the void fraction. The first part of this study is devoted to the processing of the response spectra given by the probe. The second part presents an estimation of the void fraction given by different models, a comparison between experimental and theoretical results allows to discuss their validity range. (A.C.)

  4. Laboratory measurements of vortex- and wake-induced vibrations of a tandem arrangement of two flexible risers

    Science.gov (United States)

    Liu, Huai-zeng; Wang, Fei; Jiang, Guo-sheng; Guo, Hai-yan; Li, Xiao-min

    2016-03-01

    The dynamic response of two flexible model risers in tandem arrangement immersed in a stepped current was analyzed. The risers, with an external diameter of 20 mm and a total length of 6200 mm, had an aspect ratio of 310. They were hinged to the support structure at the center-to-center distances away 3-12 times the external diameter. The top 1200 mm was exposed to a uniform current at a speed which was up to 0.9 m/s (the Reynolds number was 18000) and the rest in still water. The dynamic responses, which were obtained through the Fiber Bragg Grating strain gauges mounted on the surface, were analyzed by studying the cross-flow amplitudes and modal weights. The cross-flow vibration were observed up to the third mode, and the modal transformation from the second mode to the third mode was clearly observed. The experiment confirmed that the typical vortex-induced vibration (VIV) had occurred on the up-stream riser. But for the down-stream riser, the main excitation mechanism was wake-induced vibration (WIV). The modal transformation of WIV was more complex than that of VIV, which might be helpful for other researchers to study the interference effect.

  5. Laboratory Measurements of Vortex-and Wake-Induced Vibrations of A Tandem Arrangement of Two Flexible Risers

    Institute of Scientific and Technical Information of China (English)

    刘怀增; 王飞; 蒋国盛; 郭海燕; 李效民

    2016-01-01

    The dynamic response of two flexible model risers in tandem arrangement immersed in a stepped current was analyzed. The risers, with an external diameter of 20 mm and a total length of 6200 mm, had an aspect ratio of 310. They were hinged to the support structure at the center-to-center distances away 3-12 times the external diameter. The top 1200 mm was exposed to a uniform current at a speed which was up to 0.9 m/s (the Reynolds number was 18000) and the rest in still water. The dynamic responses, which were obtained through the Fiber Bragg Grating strain gauges mounted on the surface, were analyzed by studying the cross-flow amplitudes and modal weights. The cross-flow vibration were observed up to the third mode, and the modal transformation from the second mode to the third mode was clearly observed. The experiment confirmed that the typical vortex-induced vibration (VIV) had occurred on the up-stream riser. But for the down-stream riser, the main excitation mechanism was wake-induced vibration (WIV). The modal transformation of WIV was more complex than that of VIV, which might be helpful for other researchers to study the interference effect.

  6. Emissions estimates based on ambient N2O concentrations measured at a 200m high tower in the Netherlands 1995-1997

    International Nuclear Information System (INIS)

    In the period 1995 to 1997 the N2O concentration in ambient air at 200 m height was measured at the 200 m tower in Cabauw in the center of the Netherlands. These measurements were carried out simultaneously with CO2 and CH4 measurements. In this paper the time series for the different trace gas species are compared for the year 1995. This comparison shows the different nature of N2O as compared to the two more abundant trace gases, methane (CH4) and carbon dioxide (CO2). The diffuse character of the main N2O source in our region, the agricultural soils, in combination with the relatively poor resolution of the measurements as compared to the resolution of the CO2 and CH4 data, makes a detailed evaluation of the emissions impossible. Alternatively a simple calculation is proposed to evaluate the N2O emission for a region up to about 200 km upwind of the measurement location. This calculation uses the sudden increase in concentration that is observed after the break-up of a nocturnal inversion layer. The results of 26 nights show an emission level of 31 ±13 kton N/year. This level is lower compared to the emission level of 47.4 kton N/year that is reported for 1996 for the Netherlands using bottom up inventories. 4 refs

  7. Studies of Heterogeneously Catalyzed Liquid-Phase Alcohol Oxidation on Platinum bySum-frequency Generation Vibrational Spectroscopy and Reaction Rate Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Thompson, Christopher [Univ. of California, Berkeley, CA (United States)

    2014-05-15

    Compared to many branches of chemistry, the molecular level study of catalytically active surfaces is young. Only with the invention of ultrahigh vacuum technology in the past half century has it been possible to carry out experiments that yield useful molecular information about the reactive occurrences at a surface. The reason is two-fold: low pressure is necessary to keep a surface clean for an amount of time long enough to perform an experiment, and most atomic scale techniques that are surface speci c (x-ray photoelectron spectroscopy, electron energy loss spectroscopy, Auger electron spectroscopy, etc.) cannot be used at ambient pressures, because electrons, which act as chemical probes in these techniques, are easily scattered by molecules. Sum-frequency generation (SFG) vibrational spectroscopy is one technique that can provide molecular level information from the surface without the necessity for high vacuum. Since the advent of SFG as a surface spectroscopic tool it has proved its worth in the studies of surface catalyzed reactions in the gas phase, with numerous reactions in the gas phase having been investigated on a multitude of surfaces. However, in situ SFG characterization of catalysis at the solid-liquid interface has yet to be thoroughly pursued despite the broad interest in the use of heterogeneous catalysts in the liquid phase as replacements for homogeneous counterparts. This work describes an attempt to move in that direction, applying SFG to study the solid-liquid interface under conditions of catalytic alcohol oxidation on platinum.

  8. Model Study of the Influence of Ambient Temperature and Installation Types on Surface Temperature Measurement by Using a Fiber Bragg Grating Sensor.

    Science.gov (United States)

    Liu, Yi; Zhang, Jun

    2016-01-01

    Surface temperature is an important parameter in clinical diagnosis, equipment state control, and environmental monitoring fields. The Fiber Bragg Grating (FBG) temperature sensor possesses numerous significant advantages over conventional electrical sensors, thus it is an ideal choice to achieve high-accuracy surface temperature measurements. However, the effects of the ambient temperature and installation types on the measurement of surface temperature are often overlooked. A theoretical analysis is implemented and a thermal transfer model of a surface FBG sensor is established. The theoretical and simulated analysis shows that both substrate strain and the temperature difference between the fiber core and hot surface are the most important factors which affect measurement accuracy. A surface-type temperature standard setup is proposed to study the measurement error of the FBG temperature sensor. Experimental results show that there are two effects influencing measurement results. One is the "gradient effect". This results in a positive linear error with increasing surface temperature. Another is the "substrate effect". This results in a negative non-linear error with increasing surface temperature. The measurement error of the FBG sensor with single-ended fixation are determined by the gradient effect and is a linear error. It is not influenced by substrate expansion. Thus, it can be compensated easily. The measurement errors of the FBG sensor with double-ended fixation are determined by the two effects and the substrate effect is dominant. The measurement error change trend of the FBG sensor with fully-adhered fixation is similar to that with double-ended fixation. The adhesive layer can reduce the two effects and measurement error. The fully-adhered fixation has lower error, however, it is easily affected by substrate strain. Due to its linear error and strain-resistant characteristics, the single-ended fixation will play an important role in the FBG sensor

  9. Model Study of the Influence of Ambient Temperature and Installation Types on Surface Temperature Measurement by Using a Fiber Bragg Grating Sensor

    Directory of Open Access Journals (Sweden)

    Yi Liu

    2016-07-01

    Full Text Available Surface temperature is an important parameter in clinical diagnosis, equipment state control, and environmental monitoring fields. The Fiber Bragg Grating (FBG temperature sensor possesses numerous significant advantages over conventional electrical sensors, thus it is an ideal choice to achieve high-accuracy surface temperature measurements. However, the effects of the ambient temperature and installation types on the measurement of surface temperature are often overlooked. A theoretical analysis is implemented and a thermal transfer model of a surface FBG sensor is established. The theoretical and simulated analysis shows that both substrate strain and the temperature difference between the fiber core and hot surface are the most important factors which affect measurement accuracy. A surface-type temperature standard setup is proposed to study the measurement error of the FBG temperature sensor. Experimental results show that there are two effects influencing measurement results. One is the “gradient effect”. This results in a positive linear error with increasing surface temperature. Another is the “substrate effect”. This results in a negative non-linear error with increasing surface temperature. The measurement error of the FBG sensor with single-ended fixation are determined by the gradient effect and is a linear error. It is not influenced by substrate expansion. Thus, it can be compensated easily. The measurement errors of the FBG sensor with double-ended fixation are determined by the two effects and the substrate effect is dominant. The measurement error change trend of the FBG sensor with fully-adhered fixation is similar to that with double-ended fixation. The adhesive layer can reduce the two effects and measurement error. The fully-adhered fixation has lower error, however, it is easily affected by substrate strain. Due to its linear error and strain-resistant characteristics, the single-ended fixation will play an

  10. Model Study of the Influence of Ambient Temperature and Installation Types on Surface Temperature Measurement by Using a Fiber Bragg Grating Sensor

    Science.gov (United States)

    Liu, Yi; Zhang, Jun

    2016-01-01

    Surface temperature is an important parameter in clinical diagnosis, equipment state control, and environmental monitoring fields. The Fiber Bragg Grating (FBG) temperature sensor possesses numerous significant advantages over conventional electrical sensors, thus it is an ideal choice to achieve high-accuracy surface temperature measurements. However, the effects of the ambient temperature and installation types on the measurement of surface temperature are often overlooked. A theoretical analysis is implemented and a thermal transfer model of a surface FBG sensor is established. The theoretical and simulated analysis shows that both substrate strain and the temperature difference between the fiber core and hot surface are the most important factors which affect measurement accuracy. A surface-type temperature standard setup is proposed to study the measurement error of the FBG temperature sensor. Experimental results show that there are two effects influencing measurement results. One is the “gradient effect”. This results in a positive linear error with increasing surface temperature. Another is the “substrate effect”. This results in a negative non-linear error with increasing surface temperature. The measurement error of the FBG sensor with single-ended fixation are determined by the gradient effect and is a linear error. It is not influenced by substrate expansion. Thus, it can be compensated easily. The measurement errors of the FBG sensor with double-ended fixation are determined by the two effects and the substrate effect is dominant. The measurement error change trend of the FBG sensor with fully-adhered fixation is similar to that with double-ended fixation. The adhesive layer can reduce the two effects and measurement error. The fully-adhered fixation has lower error, however, it is easily affected by substrate strain. Due to its linear error and strain-resistant characteristics, the single-ended fixation will play an important role in the FBG

  11. Measurement of the ambient gamma dose equivalent and kerma from the small 252Cf source at 1 meter and the small 60Co source at 2 meters

    Energy Technology Data Exchange (ETDEWEB)

    Carl, W. F. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2015-07-30

    NASA Langley Research Center requested a measurement and determination of the ambient gamma dose equivalent rate and kerma at 100 cm from the 252Cf source and determination of the ambient gamma dose equivalent rate and kerma at 200 cm from the 60Co source for the Radiation Budget Instrument Experiment (Rad-X). An Exradin A6 ion chamber with Shonka air-equivalent plastic walls in combination with a Supermax electrometer were used to measure the exposure rate and free-in-air kerma rate of the two sources at the requested distances. The measured gamma exposure, kerma, and dose equivalent rates are tabulated.

  12. Development of traceable precision dynamic dilution method to generate dimethyl sulphide gas mixtures at sub-nanomole per mole levels for ambient measurement.

    Science.gov (United States)

    Kim, Mi Eon; Kim, Yong Doo; Kang, Ji Hwan; Heo, Gwi Suk; Lee, Dong Soo; Lee, Sangil

    2016-04-01

    Dimethyl sulphide (DMS) is an important compound in global atmospheric chemistry and climate change. Traceable international standards are essential for measuring accurately the long-term global trend in ambient DMS. However, developing accurate gas standards for sub-nanomole per mole (nmol/mol) mole fractions of DMS in a cylinder is challenging, because DMS is reactive and unstable. In this study, a dynamic dilution method that is traceable and precise was developed to generate sub-nmol/mol DMS gas mixtures with a dynamic dilution system based on sonic nozzles and a long-term (>5 years) stable 10 μmol/mol parent DMS primary standard gas mixtures (PSMs). The dynamic dilution system was calibrated with traceable methane PSMs, and its estimated dilution factors were used to calculate the mole fractions of the dynamically generated DMS gas mixtures. A dynamically generated DMS gas mixture and a 6 nmol/mol DMS PSM were analysed against each other by gas chromatography with flame-ionisation detection (GC/FID) to evaluate the dilution system. The mole fractions of the dynamically generated DMS gas mixture determined against a DMS PSM and calculated with the dilution factor agreed within 1% at 6 nmol/mol. In addition, the dynamically generated DMS gas mixtures at various mole fractions between 0.4 and 11.7 nmol/mol were analysed by GC/FID and evaluated for their linearity. The analytically determined mole fractions showed good linearity with the mole fractions calculated with the dilution factors. Results showed that the dynamic dilution method generates DMS gas mixtures ranging between 0.4 nmol/mol and 12 nmol/mol with relative expanded uncertainties of less than 2%. Therefore, the newly developed dynamic dilution method is a promising reference method for generating sub-nmol/mol DMS gas standards for accurate ambient measurements. PMID:26838438

  13. Urban vibrations

    DEFF Research Database (Denmark)

    Morrison, Ann; Knudsen, L.; Andersen, Hans Jørgen

    2012-01-01

    In   this   paper   we   describe   a   field   study   conducted   with   a   wearable   vibration   belt   where   we   test   to   determine   the   vibration   intensity   sensitivity   ranges   on   a   large   diverse   group   of   participants   with   evenly   distributed  ages  and......   lab   studies   in   that   we   found   a   decreased   detection   rate   in   busy   environments.   Here   we   test   with   a   much   larger   sample   and   age   range,   and   contribute   with   the   first   vibration  sensitivity  testing  outside  the  lab  in  an  urban   public...

  14. A portable smart phone-based plasmonic nanosensor readout platform that measures transmitted light intensities of nanosubstrates using an ambient light sensor.

    Science.gov (United States)

    Fu, Qiangqiang; Wu, Ze; Xu, Fangxiang; Li, Xiuqing; Yao, Cuize; Xu, Meng; Sheng, Liangrong; Yu, Shiting; Tang, Yong

    2016-05-21

    Plasmonic nanosensors may be used as tools for diagnostic testing in the field of medicine. However, quantification of plasmonic nanosensors often requires complex and bulky readout instruments. Here, we report the development of a portable smart phone-based plasmonic nanosensor readout platform (PNRP) for accurate quantification of plasmonic nanosensors. This device operates by transmitting excitation light from a LED through a nanosubstrate and measuring the intensity of the transmitted light using the ambient light sensor of a smart phone. The device is a cylinder with a diameter of 14 mm, a length of 38 mm, and a gross weight of 3.5 g. We demonstrated the utility of this smart phone-based PNRP by measuring two well-established plasmonic nanosensors with this system. In the first experiment, the device measured the morphology changes of triangular silver nanoprisms (AgNPRs) in an immunoassay for the detection of carcinoembryonic antigen (CEA). In the second experiment, the device measured the aggregation of gold nanoparticles (AuNPs) in an aptamer-based assay for the detection of adenosine triphosphate (ATP). The results from the smart phone-based PNRP were consistent with those from commercial spectrophotometers, demonstrating that the smart phone-based PNRP enables accurate quantification of plasmonic nanosensors. PMID:27137512

  15. Measurements of the ambient dose equivalent of produced x-rays at the linear accelerator UNILAC of GSI

    International Nuclear Information System (INIS)

    At the UNILAC (UNIversal Linear ACcelerator) of the GSI (Gesellschaft fuer Schwerionenforschung, facility for the research with heavy ions, Darmstadt, Germany) two different pre-stripper sections deliver ions for further acceleration. One of these consists of an ECR - ion source (Electron Cyclotron Resonance), a RFQ (Radio Frequency Quadrupole) - and an IH (Interdigital H-field) - accelerating structure. After leaving the IH - structure the ions have a specific energy of 1.4 MeV/nucleon. The ion source and the accelerating structures produce x-rays during operation. Recently various accelerator facilities for carbon ion cancer treatment - consisting of linacs and synchrotrons - were planned, are under construction or are already in operation. It turned out that data of the radiation fields near linac structures (RFQ, IH) are scarce. The aim of this paper is to improve the knowledge of the production of x-rays in the ion source and the sections of the preaccelerator. Measurements have been performed by means of various passive and active dosemeter systems. For the passive dose measurements, TLD cards (Harshaw type with 4 TLD-700 elements) partially covered by absorption layers and surrounded by a polyethylene cylinder were used, in order to adapt their reading to the x-ray energy spectra at the measurement positions. A recently developed dosemeter at GSI suitable to measure the dose quantity H*(10) in the energy range 10 keV to several MeV was applied. The measurements are carried out in the vicinity of the ECR - ion source during the production of 7Li, 12C and 48Ca ion beams. A x-ray spectrum measured with a HPGe-detector near the ECR - ion source together with the dosemeter readings give hints on the fraction of the dose caused by low energy x-rays. Spatial dose distributions of the radiation fields around the RFQ and IH structures have been measured during their operation with different accelerating voltages (the produced radiation depends strongly on the

  16. Evaluation of mobile emissions contributions to Mexico City's emissions inventory using on-road and cross-road emission measurements and ambient data

    Directory of Open Access Journals (Sweden)

    M. Zavala

    2009-03-01

    Full Text Available Mobile emissions represent a significant fraction of the total anthropogenic emissions burden in the Mexico City Metropolitan Area (MCMA and, therefore, it is crucial to use top-down techniques informed by on-road exhaust measurements to evaluate and improve traditional bottom-up official emissions inventory (EI for the city. We present the measurements of on-road fleet-average emission factors obtained using the Aerodyne mobile laboratory in the MCMA in March 2006 as part of the MILAGRO/MCMA-2006 field campaign. A comparison of our on-road emission measurements with those obtained in 2003 using essentially the same measurement techniques and analysis methods indicates that, in the three year span, NO emission factors remain within the measured variability ranges whereas emission factors of aldehydes and aromatics species were reduced for all sampled driving conditions.

    We use a top-down fuel-based approach to evaluate the mobile emissions from the gasoline fleet estimated in the bottom-up official 2006 MCMA mobile sources. Within the range of measurement uncertainties, we found probable slight overpredictions of mean EI estimates on the order of 20–28% for CO and 14–20% for NO. However, we identify a probable EI underprediction of VOC mobile emissions between 1.4 and 1.9; although estimated benzene and toluene mobile emissions in the inventory seem to be well within the uncertainties of the corresponding emissions estimates. Aldehydes mobile emissions in the inventory, however, seem to be under predicted by factors of 3 for HCHO and 2 for CH3CHO. Our on-road measurement based estimate of annual emissions of organic mass from PM1 particles suggests a severe underprediction (larger than a factor of 4 of PM2.5 mobile emissions in the inventory.

    Analyses of ambient CO, NOx and CO/NOx concentration trends in the MCMA indicate that the early morning ambient CO

  17. Evaluation of mobile emissions contributions to Mexico City's emissions inventory using on-road and cross-road emission measurements and ambient data

    Science.gov (United States)

    Zavala, M.; Herndon, S. C.; Wood, E. C.; Onasch, T. B.; Knighton, W. B.; Marr, L. C.; Kolb, C. E.; Molina, L. T.

    2009-09-01

    Mobile emissions represent a significant fraction of the total anthropogenic emissions burden in the Mexico City Metropolitan Area (MCMA) and, therefore, it is crucial to use top-down techniques informed by on-road exhaust measurements to evaluate and improve traditional bottom-up official emissions inventory (EI) for the city. We present the measurements of on-road fleet-average emission factors obtained using the Aerodyne mobile laboratory in the MCMA in March 2006 as part of the MILAGRO/MCMA-2006 field campaign. A comparison of our on-road emission measurements with those obtained in 2003 using essentially the same measurement techniques and analysis methods indicates that, in the three year span, NO emission factors remain within the measured variability ranges whereas emission factors of aldehydes and aromatics species were reduced for all sampled driving conditions. We use a top-down fuel-based approach to evaluate the mobile emissions from the gasoline fleet estimated in the bottom-up official 2006 MCMA mobile sources. Within the range of measurement uncertainties, we found probable slight overpredictions of mean EI estimates on the order of 20-28% for CO and 14-20% for NO. However, we identify a probable EI discrepancy of VOC mobile emissions between 1.4 and 1.9; although estimated benzene and toluene mobile emissions in the inventory seem to be well within the uncertainties of the corresponding emissions estimates. Aldehydes mobile emissions in the inventory, however, seem to be underpredicted by factors of 3 for HCHO and 2 for CH3CHO. Our on-road measurement-based estimate of annual emissions of organic mass from PM1 particles suggests a severe underprediction (larger than a factor of 4) of PM2.5 mobile emissions in the inventory. Analyses of ambient CO, NOx and CO/NOx concentration trends in the MCMA indicate that the early morning ambient CO/NOx ratio has decreased at a rate of about 1.9 ppm/ppm/year over the last two decades due to reductions in CO

  18. Analysis of algorithms for detection of resonance frequencies in vibration measurements on super heater tubes; Analys av algoritmer foer detektering av resonansfrekvenser i vibrationsmaetningar paa oeverhettartuber

    Energy Technology Data Exchange (ETDEWEB)

    Eriksson, Daniel

    2010-07-01

    Combustion of fuel in thermal power plants emits particles which creates coatings on the super heater tubes. The coatings isolate the tubes and impairs the efficiency of the heat transfer. Cleaning the tubes occurs while the power plant is running but without any knowledge of the actual coating. A change in frequency corresponds to a change in mass of the coatings. This thesis has been focusing in estimating resonance frequencies in vibration measurements made by strain gauges on the tubes. To improve the estimations a target tracking algorithm had been added. The results indicates that it is possible to estimate the resonance frequencies but the algorithms need to be verified on more signals.

  19. Measurement of CO concentrations in indoor and atmospheric ambient air of Birjand (September 2012 to March 2013

    Directory of Open Access Journals (Sweden)

    Ali Naghizadeh

    2015-10-01

    Full Text Available Background and Aim: One of the notorious  air pllutants on which air quality is determined is  carbon monoxide (CO. The aim of the present study was to measure the concentration of CO outdoor and indoor urban environments and compare it with air quality standards within buildings  and open spaces. Materials and Methods: This research was a descriptive-analytical study of CO estimation in outdoor and indoor air of Birjand. Concentration of CO at the height of 150 cm and in the closest street leading to the specific building and also, inside the building (i.e.drawing room-at the hight of 75 cm was measured using a CO meter. For data analysis, statistical softwares SPSS (V:18 and Excel were used applying Mann-Whitney, Friedman, and Wilcoxon statistical tests. Results: It was found that the highest concentrations of CO in the outdoor air in Birjand were 11 and 10 ppm in December and March, respectively. And highest concentrations of CO in indoor air were 11 and 9 ppm in February, respectively. But, in general, the average concentration of CO measured in outdoor and indoor air quality in both months were less than the standard measure air pollution outside (9ppm and the quality of indoor air pollution (25ppm. Conclusion: Regarding to results of the present study, concentrations of indoor and outdoor CO of Birjand air were in standard ranges.

  20. First Measurements of Ambient Total Gaseous Mercury (TGM at the EvK2CNR Pyramid Observatory in Nepal

    Directory of Open Access Journals (Sweden)

    Gratz L. E.

    2013-04-01

    Full Text Available As part of the Global Mercury Observation System (GMOS project, a global-scale network of ground-based atmospheric monitoring sites is being developed with the objective of expanding the global coverage of atmospheric mercury (Hg measurements and improving our understanding of global atmospheric Hg transport. An important addition to the GMOS monitorng network has been the high altitude EvK2CNR Pyramid Observatory, located at an elevation of 5,050 meters a.s.l. in the eastern Himalaya Mountains of Nepal. Monitoring of total gaseous mercury (TGM using the Tekran 2537A Mercury Vapor Analyzer began at the EvK2CNR Pyramid Observatory in November 2011. From 17 November 2011 to 23 April 2012, the mean concentration of TGM at the Pyramid was 1.2 ng m−3. A range of concentrations from 0.7 to 2.6 ng m−3 has been observed. These are the first reported measurements of atmospheric Hg in Nepal, and currently this is the highest altitude monitoring station for atmospheric Hg in the world. It is anticipated that these high quality measurements, in combination with the other continuous atmospheric measurments being collected at the Pyramid station, will help to further our understanding of Hg concentrations in the free troposphere and the transport of atmospheric Hg on the global scale.

  1. Ambient measurements of OH and HO2 radicals and the OH reactivity in and above the Borneo Rainforest

    Science.gov (United States)

    Heard, D. E.; Whalley, L. K.; Furneaux, K. L.; Edwards, P.; Commane, R.; Goddard, A.; Ingham, T.; Evans, M.

    2008-12-01

    Ground-based measurements of OH, HO2 and the OH reactivity have been made as part of the OP3 project that took place at the Bukit Atur Global Atmospheric Watch station in the Danum Valley forest conservation area in Sabah, Borneo in 2008. The project consisted of two intensive measurement periods in April and July. Aircraft measurements of OH and HO2 above the ground site were also performed and preliminary data will be presented. The OH and HO2 radicals exhibit a distinct diurnal profile, broadly following the j(O1D) profile that was measured simultaneously (daytime [OH] ~ 2 - 5 x 106 molecule cm-3, [HO2] ~ 1 - 1.5 x 108 molecule cm-3). NO, which peaked in the early morning hours ([NO] ~ 100 pptV) and isoprene, which peaked in the afternoon ([isoprene] ~ 2 - 5 ppbV) were found to influence the OH profile. Both OH and HO2 persisted into the night and were detectable even after j(O1D) had fallen to zero (nighttime [OH] ~ 2.5 x 105 molecule cm-3, [HO2] ~ 2 x 107 molecule cm-3), suggesting night-time radical sources. The OH reactivity tracked the isoprene concentration, exhibiting maximum reactivity just after midday when isoprene levels peaked. Zero dimensional models, using a variety of mechanisms, have been used to predict the [OH], [HO2] and the OH reactivity that were observed. The models, constrained with measured OH sources and sinks, are used to test the hypothesis that OH is recycled from isoprene oxidation in this low NOx environment

  2. Characteristics of Vibration Induced by Cavitation

    Institute of Scientific and Technical Information of China (English)

    WANG Guo-yu; TAO Lei; LIU Shu-yan; QIAN Jian-jun

    2005-01-01

    Cavitation-induced vibration characteristics and the relations between the vibration and cavitation are studied. Cavitation vibrations are measured around a model hollow-jet valve by an accelerometer under cavitating and non-cavitating conditions. The measurement data is analyzed by FFT method. The corresponding cavitating flow patterns are photographed by a high-speed camera with an xenon flash lamp. The frequency band of the vibration induced by cavitation is determined. To compare the vibration intensities under different cavitation conditions, a definition of vibration acceleration level is introduced based on power spectral density of the vibration. By the analysis of vibration, the definitions of characteristic cavitation number are suggested. According to these cavitation numbers, the cavitation process is divided into three stages, that is, incipient cavitation, subcavitation and supercavitation.

  3. A Novel Self-Powered Wireless Sensor Node Based on Energy Harvesting for Mechanical Vibration Monitoring

    Directory of Open Access Journals (Sweden)

    Xihai Zhang

    2014-01-01

    Full Text Available Wireless sensor networks (WSNs have been expected to improve the capability of capturing mechanical vibration dynamic behaviors and evaluating the current health status of equipment. While the expectation for mechanical vibration monitoring using WSNs has been high, one of the key limitations is the limited lifetime of batteries for sensor node. The energy harvesting technologies have been recently proposed. One of them shares the same main idea, that is, energy harvesting from ambient vibration can be converted into electric power. Employing the vibration energy harvesting, a novel self-powered wireless sensor node has been developed to measure mechanical vibration in this paper. The overall architecture of node is proposed. The wireless sensor node is described into four main components: the energy harvesting unit, the microprocessor unit, the radio transceiver unit, and accelerometer. Moreover, the software used to control the operation of wireless node is also suggested. At last, in order to achieve continuous self-powered for nodes, two operation modes including the charging mode and discharging mode are proposed. This design can effectively solve the problem of continuous supply power of sensor node for mechanical vibration monitoring.

  4. Advanced time average holographic method for measurement in extensive vibration amplitude range with quantitative single-pixel analysis

    Czech Academy of Sciences Publication Activity Database

    Psota, P.; Lédl, Vít; Vojtíšek, P.; Václavík, Jan; Doleček, Roman; Mokrý, P.

    Vol. 9508. Bellingham : SPIE-INT SOC OPTICAL ENGINEERING, 2015 - (Hrabovsky, M.; Sheridan, J.; Fimia, A.), 95080N-95080N ISBN 978-1-62841-629-9. ISSN 0277-786X. - (SPIE). [Conference on Holography - Advances and Modern Trends IV. Prague (CZ), 15.04.2015-16.04.2015] R&D Projects: GA ČR GA13-10365S Institutional support: RVO:61389021 Keywords : Time average holography * frequency modulation * phase modulation * digital holography * vibration analysis Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering http://spie.org/Publications/Proceedings/Volume/9508

  5. Vibrating minds

    CERN Multimedia

    2009-01-01

    Ed Witten is one of the leading scientists in the field of string theory, the theory that describes elementary particles as vibrating strings. This week he leaves CERN after having spent a few months here on sabbatical. His wish is that the LHC will unveil supersymmetry.

  6. Vibrating Manipulation

    Institute of Scientific and Technical Information of China (English)

    SHEN Guo-quan; CUI Yi-jun

    2003-01-01

    @@ As a manipulation with unique therapeutic effect in TCM Tuina manipulations, Vibrating manipulation has significantly stronger effection on viscera, blood vessel, smooth muscle and gland secretion than other Tuina manipulations and it is mainly used in internal medicine, gynecology and miscellaneous diseases.

  7. Practical measuring system for the ambient equivalent dose rate by PSF driven by USB and its actual results

    International Nuclear Information System (INIS)

    This paper describes the detailed system in the title developed, and results obtained by its actual application to a contaminated region around Fukushima prefecture. The system is driven by USB, measures the linear distribution of the dose with plastic scintillation fiber (PSF), by parallel moving of which, the plane distribution of the dose can be measurable. The system is composed from 4 components of the radio-sensor PSF, photon detectors, pulse processor where the photon signal is converted to position information with time-of-flight principle, and display on PC. Three kinds of exchangeable PSF (length 20 m) with different bundle numbers (12, 7 and 1) are prepared to measure the low, middle and high dose levels of radiation, respectively, and each is rigidified by insertion in the individual metal flexible tube. The processor can convert the count rate to dose rate with linearity corrected by 137Cs gamma source; e.g., for the low dose rate, 0.1-10 mcSv, linearity is confirmed. The processor has 3 cables and 550 g weight in contrast to the ordinary machine's 12 cables and 20 kg. PSF and processor are waterproof for outdoor use. A software for mapping the measured results is also developed for color display. Mapping results of the application of the system to 80 m x 60 m site around a public hall and the swimming pool of a primary school are quite persuasive before and after de-contamination work like disappearance of hot spots after the work, and suggestive of its usefulness in dealing with the Fukushima contamination problems. (T.T.)

  8. [Study on the measurement of ambient ammonia in urban area based on open-path DOAS technique].

    Science.gov (United States)

    Wang, Jie; Xie, Pin-hua; Qin, Min; Ling, Liu-yi; Ye, Cong-lei; Liu, Jian-guo; Liu, Wen-qing

    2012-02-01

    As a key role in the acid-deposition and the generation of secondary particle matter (PM), measurement of the concentration of atmospheric ammonia in urban area has been attracting the scientists' interests nowadays. After studying the special absorption features of ammonia in short UV wavelength range, detailed concernful issues were put forward in the present paper. The decision of using xenon lamp as the light source was made after the evaluation of measurement of light spectroscopy. Retrieval wavelength band for NH3 was fixed from 204 to 214 nm and optimal method of deducting other interferential gases was also shown. A home-made open-path DOAS (OP-DOAS) system was set up for the measurement of the concentration of atmospheric NH3. The detection limit of such system was calculated with the typical noise level as low as 0.33 microg x m(-3) with the optical path 228 m. Through field experiment in Guangzhou city, such a system can be competent for the online and high time-resolution monitoring of the concentration of atmospheric ammonia. With a significant diurnal variation, the atmospheric ammonia changed from 0.83 to 3.11 microg x m(-3) with the mean value 1.59 microg x m(-3). The representative character of the diurnal variation is that the concentration of NH3 peaks during night while drops to bottom in the daytime. After the error analysis procedure, typical measurement accuracy of such OP-DOAS system was within 10%. PMID:22512193

  9. Thermal conductivity of silver loaded conductive epoxy from cryogenic to ambient temperature and its application for precision cryogenic noise measurements

    Science.gov (United States)

    Amils, Ricardo I.; Gallego, Juan Daniel; Sebastián, José Luis; Muñoz, Sagrario; Martín, Agustín; Leuther, Arnulf

    2016-06-01

    The pressure to increase the sensitivity of instrumentation has pushed the use of cryogenic Low Noise Amplifier (LNA) technology into a growing number of fields. These areas range from radio astronomy and deep space communications to fundamental physics. In this context manufacturing for cryogenic environments requires a proper thermal knowledge of the materials to be able to achieve adequate design behavior. In this work, we present experimental measurements of the thermal conductivity of a silver filled conductive epoxy (EPO-TEK H20E) which is widely used in cryogenic electronics applications. The characterization has been made using a sample preparation which mimics the practical use of this adhesive in the fabrication of cryogenic devices. We apply the data obtained to a detailed analysis of the effects of the conductive epoxy in a monolithic thermal noise source used for high accuracy cryogenic microwave noise measurements. In this application the epoxy plays a fundamental role since its limited thermal conductivity allows heating the chip with relatively low power. To our knowledge, the cryogenic thermal conductivity data of this epoxy has not been reported before in the literature in the 4-300 K temperature range. A second non-conductive epoxy (Gray Scotch-Weld 2216 B/A), also widely used in cryogenic applications, has been measured in order to validate the method by comparing with previous published data.

  10. Fiber optic vibration sensor

    Science.gov (United States)

    Dooley, Joseph B.; Muhs, Jeffrey D.; Tobin, Kenneth W.

    1995-01-01

    A fiber optic vibration sensor utilizes two single mode optical fibers supported by a housing with one optical fiber fixedly secured to the housing and providing a reference signal and the other optical fiber having a free span length subject to vibrational displacement thereof with respect to the housing and the first optical fiber for providing a signal indicative of a measurement of any perturbation of the sensor. Damping or tailoring of the sensor to be responsive to selected levels of perturbation is provided by altering the diameter of optical fibers or by immersing at least a portion of the free span length of the vibration sensing optical fiber into a liquid of a selected viscosity.

  11. Predicting the behavior of a grid-connected photovoltaic system from measurements of solar radiation and ambient temperature

    International Nuclear Information System (INIS)

    Highlights: ► A model to predict in a reliable way the behavior of a GCPV system is presented. ► Radiation and temperature behavior were shaped with probability density functions. ► This probability density functions were made from real measurements. ► This model was verified for comparing their behavior with real measurements. ► It can be used in any electrical systems language which have programming routines. - Abstract: This paper presents a methodology to predict in a statistically reliable way the behavior of a grid-connected photovoltaic system. The methodology developed can be implemented either in common programming software or through an off-the-shelf simulation of electrical systems. Initially, the atmospheric parameters that influence the behavior of PV generators (radiation and temperature) are characterized in a probabilistic manner. In parallel, a model compound by various PV generator components is defined: the modules (and their electrical and physical characteristics), their connection to form the generator, and the inverter type. This model was verified for comparing their behavior with output measured on a real installed system of 3.6 kWp. The solar resource characterized and the photovoltaic system model are integrated in a non-deterministic approach using the stochastic Monte Carlo method, developed in the programming language DPL of the electrical-systems simulation software DIGSILENT®. It is done to estimate the steady-state electrical parameters describing the influence of the grid-connected photovoltaic system. Specifically, we estimated the nominal peak power of the PV generator to minimize network losses, subject to constraints on nodes voltages and conductor currents

  12. Measurement of CO concentrations in indoor and atmospheric ambient air of Birjand (September 2012 to March 2013)

    OpenAIRE

    Ali Naghizadeh; Gholamreza Sharifzadeh; Marzieh Khavari

    2015-01-01

    Background and Aim: One of the notorious  air pllutants on which air quality is determined is  carbon monoxide (CO). The aim of the present study was to measure the concentration of CO outdoor and indoor urban environments and compare it with air quality standards within buildings  and open spaces. Materials and Methods: This research was a descriptive-analytical study of CO estimation in outdoor and indoor air of Birjand. Concentration of CO at the height of 150 cm and in ...

  13. Vertical and Horizontal Measurements of Ambient Ozone over a Gas and Oil Production Area using a UAV Platform

    Science.gov (United States)

    Jensen, A.; Gowing, I.; Martin, R. S.

    2013-12-01

    During the 2013 wintertime Uintah Basin Ozone Study (UBOS13), an autonomous unmanned aerial vehicle (UAV) platform, coupled with an on-board UV ozone monitor, flew several spatial profiles near the location (Horse Pool) of other concentrated measurements by other co-investigators. The airframe, part of the Utah Water Research Laboratory's (UWRL) AggieAir UAV program, consisted of a custom-built, battery-operated plane with and 2.4 m (8 ft) wing span and a 12.7 cm x 12.7 cm x 30.5 cm payload bay with a carrying capacity of approximately 2.0 kg. With the current power system, the fully-loaded AggieAir UAV can fly for approximately 45 minutes at a nominal airspeed of 13.4 m/s (30 mph). The system can be operated either in manual control or be flown autonomously following preprogrammed waypoints via a built in GPS system. The AggieAir UAV systems were primarily designed for photographic and telemetry tracking projects. For the UBOS13 flights, a 2B Technologies Model 205 Ozone (O3) monitor was modified for minimal weight optimization, wrapped with lightweight insulation and secured into the UAV payload bay. Additionally, HOBO Model H08-001-02 shielded temperature/datalogger was secured to the exterior of the UAV from parallel thermal profile determination. During the study period, three demonstration flight profiles were obtained on February 17 and 18, 2013: two vertical 'curtain' profiles and a pair of 'stacked' horizontal profiles. As recorded by numerous ground-based monitoring sites, the ozone during the UAV test periods was characterized by initial trends of daytime O3 maximums over 130 ppb, followed by a meteorological front partially ventilating the Basin on the evening of Feb. 17th leading to decreased O3 minimums around 40 ppb. However, the ground level O3 rebuilt quickly to ground level maximums approaching 100 ppb. The vertical 'curtain' flown on the evening of Feb. 17th only reached a maximum elevation of about 2160 m ASL (600 m AGL) due to encountering

  14. Environmental radioactivity measurements in the autonomous community of Aragon; Medidas de la radiactividad ambiental en la comunidad autonoma de Aragon

    Energy Technology Data Exchange (ETDEWEB)

    Calvete, H.; Carrion, A.; Gale, C.; Garcia, E.; Nunez-Lagos, R.; Perez, C.; Puimedon, J.; Rodriguez, S.; Sanchez, P.; Sarsa, M. L.; Villar, J. A.

    2011-07-01

    To know the level of environmental radioactivity in the Autonomous Community of Aragon thermoluminescent dosimeters used to measure the cumulative dose over a period of time in each of its 33 counties. The project, funded by the Government of Aragon and La Caixa to carry a map of environmental radioactivity with the collaboration of Secondary Schools and public schools for the renovation and shipment of dosimeters. The selection of the different locations was carried out taking into account the points of interest in the project reflected Marna, by ENUSA and the CSN, on natural gamma radiation. The work program began in 2009 and to date working with 43 centers distributed throughout the community tried to cover a wide surface area of Aragon. (Author)

  15. A method for the direct measurement of electronic site populations in a molecular aggregate using two-dimensional electronic-vibrational spectroscopy.

    Science.gov (United States)

    Lewis, Nicholas H C; Dong, Hui; Oliver, Thomas A A; Fleming, Graham R

    2015-09-28

    Two dimensional electronic spectroscopy has proved to be a valuable experimental technique to reveal electronic excitation dynamics in photosynthetic pigment-protein complexes, nanoscale semiconductors, organic photovoltaic materials, and many other types of systems. It does not, however, provide direct information concerning the spatial structure and dynamics of excitons. 2D infrared spectroscopy has become a widely used tool for studying structural dynamics but is incapable of directly providing information concerning electronic excited states. 2D electronic-vibrational (2DEV) spectroscopy provides a link between these domains, directly connecting the electronic excitation with the vibrational structure of the system under study. In this work, we derive response functions for the 2DEV spectrum of a molecular dimer and propose a method by which 2DEV spectra could be used to directly measure the electronic site populations as a function of time following the initial electronic excitation. We present results from the response function simulations which show that our proposed approach is substantially valid. This method provides, to our knowledge, the first direct experimental method for measuring the electronic excited state dynamics in the spatial domain, on the molecular scale. PMID:26429003

  16. A method for the direct measurement of electronic site populations in a molecular aggregate using two-dimensional electronic-vibrational spectroscopy

    International Nuclear Information System (INIS)

    Two dimensional electronic spectroscopy has proved to be a valuable experimental technique to reveal electronic excitation dynamics in photosynthetic pigment-protein complexes, nanoscale semiconductors, organic photovoltaic materials, and many other types of systems. It does not, however, provide direct information concerning the spatial structure and dynamics of excitons. 2D infrared spectroscopy has become a widely used tool for studying structural dynamics but is incapable of directly providing information concerning electronic excited states. 2D electronic-vibrational (2DEV) spectroscopy provides a link between these domains, directly connecting the electronic excitation with the vibrational structure of the system under study. In this work, we derive response functions for the 2DEV spectrum of a molecular dimer and propose a method by which 2DEV spectra could be used to directly measure the electronic site populations as a function of time following the initial electronic excitation. We present results from the response function simulations which show that our proposed approach is substantially valid. This method provides, to our knowledge, the first direct experimental method for measuring the electronic excited state dynamics in the spatial domain, on the molecular scale

  17. Multifrequency swept common-path en-face OCT for wide-field measurement of interior surface vibrations in thick biological tissues.

    Science.gov (United States)

    Choi, Samuel; Watanabe, Tomoya; Suzuki, Takamasa; Nin, Fumiaki; Hibino, Hiroshi; Sasaki, Osami

    2015-08-10

    Microvibrations that occur in bio-tissues are considered to play pivotal roles in organ function; however techniques for their measurement have remained underdeveloped. To address this issue, in the present study we have developed a novel optical coherence tomography (OCT) method that utilizes multifrequency swept interferometry. The OCT volume data can be acquired by sweeping the multifrequency modes produced by combining a tunable Fabry-Perot filter and an 840 nm super-luminescent diode with a bandwidth of 160 nm. The system employing the wide-field heterodyne method does not require mechanical scanning probes, which are usually incorporated in conventional Doppler OCTs and heterodyne-type interferometers. These arrangements allow obtaining not only 3D tomographic images but also various vibration parameters such as spatial amplitude, phase, and frequency, with high temporal and transverse resolutions over a wide field. Indeed, our OCT achieved the axial resolution of ~2.5 μm when scanning the surface of a glass plate. Moreover, when examining a mechanically resonant multilayered bio-tissue in full-field configuration, we captured 22 nm vibrations of its internal surfaces at 1 kHz by reconstructing temporal phase variations. This so-called "multifrequency swept common-path en-face OCT" can be applied for measuring microdynamics of a variety of biological samples, thus contributing to the progress in life sciences research. PMID:26367958

  18. A method for the direct measurement of electronic site populations in a molecular aggregate using two-dimensional electronic-vibrational spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, Nicholas H. C.; Dong, Hui; Oliver, Thomas A. A.; Fleming, Graham R., E-mail: grfleming@lbl.gov [Department of Chemistry, University of California, Berkeley, California 94720 (United States); Physical Biosciences Division, Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States); Kavli Energy Nanosciences Institute at Berkeley, Berkeley, California 94720 (United States)

    2015-09-28

    Two dimensional electronic spectroscopy has proved to be a valuable experimental technique to reveal electronic excitation dynamics in photosynthetic pigment-protein complexes, nanoscale semiconductors, organic photovoltaic materials, and many other types of systems. It does not, however, provide direct information concerning the spatial structure and dynamics of excitons. 2D infrared spectroscopy has become a widely used tool for studying structural dynamics but is incapable of directly providing information concerning electronic excited states. 2D electronic-vibrational (2DEV) spectroscopy provides a link between these domains, directly connecting the electronic excitation with the vibrational structure of the system under study. In this work, we derive response functions for the 2DEV spectrum of a molecular dimer and propose a method by which 2DEV spectra could be used to directly measure the electronic site populations as a function of time following the initial electronic excitation. We present results from the response function simulations which show that our proposed approach is substantially valid. This method provides, to our knowledge, the first direct experimental method for measuring the electronic excited state dynamics in the spatial domain, on the molecular scale.

  19. SU-E-T-403: Measurement of the Neutron Ambient Dose Equivalent From the TrueBeam Linac Head and Varian 2100 Clinac

    International Nuclear Information System (INIS)

    Purpose: High-energy x-ray therapy produces an undesirable source of stray neutron dose to healthy tissues, and thus, poses a risk for second cancer induction years after the primary treatment. Hence, the purpose of this study was to measure the neutron ambient dose equivalent, H*(10), produced from the TrueBeam and Varian 2100 linac heads, respectively. Of particular note is that there is no measured data available in the literature on H*(10) production from the TrueBeam treatment head. Methods: Both linacs were operated in flattening filter mode using a 15 MV x-ray beam on TrueBeam and an 18 MV x-ray beam for the Varian 2100 Clinac with the jaws and multileaf collimators in the fully closed position. A dose delivery rate of 600 MU/min was delivered on the TrueBeam and the Varian 2100 Clinac, respectively and the H*(10) rate was measured in triplicate using the WENDI-2 detector located at multiple positions including isocenter and longitudinal (gun-target) to the isocenter. Results: For each measurement, the H*(10) rate was relatively constant with increasing distance away from the isocenter with standard deviations on the order of a tenth of a mSv/h or less for the given beam energy. In general, fluctuations in the longitudinal H*(10) rate between the anterior-posterior couch directions were approximately a percent for both beam energies. Conclusion: Our preliminary results suggest an H*(10) rate of about 30 mSv/h (40 mSv/h) or less for TrueBeam (Varian Clinac 2100) for all measurements considered in this study indicating a relatively low contribution of produced secondary neutrons to the primary therapeutic beam

  20. Retrieving historical ambient PM2.5 concentrations using existing visibility measurements in Xi'an, Northwest China

    Science.gov (United States)

    Shen, Zhenxing; Cao, Junji; Zhang, Leiming; Zhang, Qian; Huang, R.-J.; Liu, Suixin; Zhao, Zhuzi; Zhu, Chongshu; Lei, Yali; Xu, Hongmei; Zheng, Chunli

    2016-02-01

    Long term fine particulate matter (PM2.5) data are needed to assess air quality and climate issues, but PM2.5 data have only been monitored in the recent decade in Chinese cities. Considering strong correlations between PM2.5 and visibility, regression models can be useful tools for retrieving historical PM2.5 data from available visibility data. In this study, PM2.5 and visibility data are both available during 2004-2011 in Xi'an, a megacity in northwest China. Data from 2004 to 2007 were used to develop a regression model and those from 2008 to 2011 were used to evaluate the model. An exponential regression model was then chosen to retrieve the historical PM2.5 data from 1979 to 2003, which were then analyzed together with the measured data from 2004 to 2011 for long term trends. Seasonal PM2.5 increased from 1979 to 2011 with the fastest increase in winter and the slowest in summer. Annual average PM2.5 followed into three distinct periods with a slow decreasing trend from 1979 to 1996, a sharp increasing trend from 1997 to 2006, and a slow decreasing trend from 2007 to 2011. These increasing and decreasing trends are in agreement with the evolution of industrial development in Xi'an.

  1. Nonlinear effects in electrostatic vibration energy harvesters: current progress and perspectives

    OpenAIRE

    Galayko, Dimitri; Blokhina, Elena

    2013-01-01

    In this review paper, we discuss the principles of electrostatic (capacitive) vibration energy harvesters and nonlinear techniques that can be applied to improve the performance of harvesters. Electrostatic vibration energy harvesters are devices that contain mechanical resonators driven by ambient vibrations and coupled with conditioning electronic circuits through a capacitive transducer. While the devices can be fabricated using MEMS technology and miniaturised, intern...

  2. Analysis of multi-band pyrometry for emissivity and temperature measurements of gray surfaces at ambient temperature

    Science.gov (United States)

    Araújo, António

    2016-05-01

    A multi-band pyrometry model is developed to evaluate the potential of measuring temperature and emissivity of assumably gray target surfaces at 300 K. Twelve wavelength bands between 2 and 60 μm are selected to define the spectral characteristics of the pyrometers. The pyrometers are surrounded by an enclosure with known background temperature. Multi-band pyrometry modeling results in an overdetermined system of equations, in which the solution for temperature and emissivity is obtained through an optimization procedure that minimizes the sum of the squared residuals of each system equation. The Monte Carlo technique is applied to estimate the uncertainties of temperature and emissivity, resulting from the propagation of the uncertainties of the pyrometers. Maximum reduction in temperature uncertainty is obtained from dual-band to tri-band systems, a small reduction is obtained from tri-band to quad-band, with a negligible reduction above quad-band systems (a reduction between 6.5% and 12.9% is obtained from dual-band to quad-band systems). However, increasing the number of bands does not always reduce uncertainty, and uncertainty reduction depends on the specific band arrangement, indicating the importance of choosing the most appropriate multi-band spectral arrangement if uncertainty is to be reduced. A reduction in emissivity uncertainty is achieved when the number of spectral bands is increased (a reduction between 6.3% and 12.1% is obtained from dual-band to penta-band systems). Besides, emissivity uncertainty increases for pyrometers with high wavelength spectral arrangements. Temperature and emissivity uncertainties are strongly dependent on the difference between target and background temperatures: uncertainties are low when the background temperature is far from the target temperature, tending to very high values as the background temperature approaches the target temperature.

  3. An intercomparison of GC-FID and PTR-MS toluene measurements in ambient air under conditions of enhanced monoterpene loading

    Directory of Open Access Journals (Sweden)

    J. L. Ambrose

    2010-01-01

    Full Text Available Toluene was measured using both a gas chromatographic system (GC, with a flame ionization detector (FID, and a proton transfer reaction-mass spectrometer (PTR-MS at the AIRMAP atmospheric monitoring station Thompson Farm (THF in rural Durham, NH during the summer of 2004. Simultaneous measurements of monoterpenes, including α- and β-pinene, camphene, Δ3-carene, and d-limonene, by GC-FID demonstrated large enhancements in monoterpene mixing ratios relative to toluene, with median and maximum enhancement ratios of ~2 and ~30, respectively. A detailed intercomparison among the GC-FID and PTR-MS toluene measurements was conducted to test the specificity of PTR-MS for atmospheric toluene measurements under conditions often dominated by biogenic emissions. We derived quantitative estimates of potential interferences in the PTR-MS toluene measurements related to sampling and analysis of monoterpenes, including fragmentation of the monoterpenes and some of their primary carbonyl oxidation products via reactions with H3O+, O2+ and NO+ in the PTR-MS drift tube. The PTR-MS and GC-FID toluene measurements were in good quantitative agreement and the two systems tracked one another well from the instrumental limits of detection to maximum mixing ratios of ~0.5 ppbv. Discrepancies in the measured mixing ratios were not well correlated with enhancements in the monoterpenes. Better quantitative agreement between the two systems was obtained by correcting the PTR-MS measurements for contributions from monoterpene fragmentation in the PTR-MS drift tube; however, the improvement was minor. Interferences in the PTR-MS measurements from fragmentation of the monoterpene oxidation products pinonaldehyde, caronaldehyde and α-pinene oxide were also likely negligible. The results from THF suggest that toluene can be reliably quantified by PTR-MS using our operating conditions under the ambient

  4. The origins of vibration theory

    Science.gov (United States)

    Dimarogonas, A. D.

    1990-07-01

    The Ionian School of natural philosophy introduced the scientific method of dealing with natural phenomena and the rigorous proofs for abstract propositions. Vibration theory was initiated by the Pythagoreans in the fifth century BC, in association with the theory of music and the theory of acoustics. They observed the natural frequency of vibrating systems and proved that it is a system property and that it does not depend on the excitation. Pythagoreans determined the fundamental natural frequencies of several simple systems, such as vibrating strings, pipes, vessels and circular plates. Aristoteles and the Peripatetic School founded mechanics and developed a fundamental understanding of statics and dynamics. In Alexandrian times there were substantial engineering developments in the field of vibration. The pendulum as a vibration, and probably time, measuring device was known in antiquity, and was further developed by the end of the first millennium AD.

  5. Vibration sensors

    International Nuclear Information System (INIS)

    These sensors, which aim is the surveillance of the fast breeder reactor internal structure, were designed considering the following requirements: - long term utilization under low frequencies conditions (1 to 50 Hz) and detection of accelerations lower than 0,01 g, - operation with a temperature up to 6000C and receiving important neutron and gamma flux. Monoaxial sensors with a liquid vibrating mass (sodium) were thus developed, based on the electromagnetic flow meter principles (Faraday effect)

  6. Vibration Principles and Measures of Discharge Piping in Reciprocating Compressor%往复式压缩机出口管道振动原理及解决措施

    Institute of Scientific and Technical Information of China (English)

    李力

    2015-01-01

    Reciprocating compressor is widely used in chemical plants.If its discharge piping is not designed properly, it will result in vibrating and threatening the safety of the plant.This article analyzes the vibration principles of reciprocating compressor discharge piping, expounds its vibration-proof design, and puts forward measures to reduce vibration.%往复式压缩机在化工装置中应用非常广泛,但其出口管道如果设计不当,则很容易引起振动,从而对装置的安全造成威胁. 本文剖析了往复式压缩机出口管道的振动原理,论述了往复式压缩机出口管道的防振设计,并提出了消减振动的措施.

  7. Seeing the vibrational breathing of a single molecule through time-resolved coherent anti-Stokes Raman scattering

    CERN Document Server

    Yampolsky, Steven; Dey, Shirshendu; Hulkko, Eero; Banik, Mayukh; Potma, Eric O; Apkarian, Vartkess A

    2014-01-01

    The motion of chemical bonds within molecules can be observed in real time, in the form of vibrational wavepackets prepared and interrogated through ultrafast nonlinear spectroscopy. Such nonlinear optical measurements are commonly performed on large ensembles of molecules, and as such, are limited to the extent that ensemble coherence can be maintained. Here, we describe vibrational wavepacket motion on single molecules, recorded through time-resolved, surface-enhanced, coherent anti-Stokes Raman scattering. The required sensitivity to detect the motion of a single molecule, under ambient conditions, is achieved by equipping the molecule with a dipolar nano-antenna (a gold dumbbell). In contrast with measurements in ensembles, the vibrational coherence on a single molecule does not dephase. It develops phase fluctuations with characteristic statistics. We present the time evolution of discretely sampled statistical states, and highlight the unique information content in the characteristic, early-time probabi...

  8. Ambient noise near the sea-route

    Institute of Scientific and Technical Information of China (English)

    HE Li; LI ZhengLin; PENG ZhaoHui

    2009-01-01

    Ambient noise data measured in an experiment conducted in shallow water near a sea-route were analyzed. It was observed that, at low frequency, the horizontal correlation has an obvious difference from that predicted by the classical ambient noise model. The theoretical analyses show that this phenomenon is caused by wind noise together with the discrete shipping noise nearby. An ambient noise model was proposed to include the effects caused by both the noise sources. Data measured at different times verify that the proposed model can be used to forecast the ambient noise field in shal-low water near the sea-route.

  9. Ambient noise near the sea-route

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    Ambient noise data measured in an experiment conducted in shallow water near a sea-route were analyzed. It was observed that, at low frequency, the horizontal correlation has an obvious difference from that predicted by the classical ambient noise model. The theoretical analyses show that this phenomenon is caused by wind noise together with the discrete shipping noise nearby. An ambient noise model was proposed to include the effects caused by both the noise sources. Data measured at different times verify that the proposed model can be used to forecast the ambient noise field in shallow water near the sea-route.

  10. Vibrational Dynamics of Biological Molecules: Multi-quantum Contributions

    OpenAIRE

    Bogdan M. Leu; Timothy Sage, J.; Zgierski, Marek Z.; Wyllie, Graeme R. A.; Ellison, Mary K.; Robert Scheidt, W.; Sturhahn, Wolfgang; Ercan Alp, E.; Durbin, Stephen M.

    2005-01-01

    High-resolution X-ray measurements near a nuclear resonance reveal the complete vibrational spectrum of the probe nucleus. Because of this, nuclear resonance vibrational spectroscopy (NRVS) is a uniquely quantitative probe of the vibrational dynamics of reactive iron sites in proteins and other complex molecules. Our measurements of vibrational fundamentals have revealed both frequencies and amplitudes of 57Fe vibrations in proteins and model compounds. Information on the direction of Fe moti...

  11. Adaptability of drowsiness level detection that measures blinks utilizing image processing to changes in the ambient light; Hikari kankyo no henka ni tekiosuru kao gazo shori ni yoru inemuri unten kenchi

    Energy Technology Data Exchange (ETDEWEB)

    Kaneda, M.; Obara, H.; Nasu, T. [Nissan Motor Co. Ltd, Tokyo (Japan)

    1997-10-01

    A drowsiness warning system that measures blinks utilizing image processing technology has a number of issues that need to be resolved. One issue is the adaptability of the system to changes in the ambient light environment in the actual vehicle interior. We have devised image processing software which is robust to changes in the ambient light. The drowsiness detection performance of the system was evaluated in laboratory tests and actual driving tests. It was found that the system can has a positive effect on detecting drowsiness level. 3 refs., 10 figs.

  12. A comparison of GC-FID and PTR-MS toluene measurements in ambient air under conditions of enhanced monoterpene loading

    Directory of Open Access Journals (Sweden)

    J. L. Ambrose

    2010-07-01

    correcting the PTR-MS measurements for contributions from monoterpene fragmentation in the PTR-MS drift tube; however, the improvement was minor (<10%. Interferences in the PTR-MS measurements from fragmentation of the monoterpene oxidation products pinonaldehyde, caronaldehyde and α-pinene oxide were also likely negligible. A relatively large and variable toluene background in the PTR-MS instrument likely drove the measurement bias; however, the precise contribution was difficult to accurately quantify and thus was not corrected for in this analysis. The results from THF suggest that toluene can be reliably quantified by PTR-MS using our operating conditions (drift tube pressure, temperature and voltage of 2.0 mbar, 45 °C and 600 V, respectively under the ambient compositions probed. This work extends the range of field conditions under which PTR-MS validation studies have been conducted.

  13. Identification of potential sources and source regions of fine ambient particles measured at Gosan background site in Korea using advanced hybrid receptor model combined with positive matrix factorization

    Science.gov (United States)

    Han, J. S.; Moon, K. J.; Kim, Y. J.

    2006-11-01

    The size- and time-resolved measurement of particulate trace elements was made using an eight-stage Davis Rotating Unit for Monitoring sampler and synchrotron X-ray fluorescence system from 29 March to 29 May in 2002 at Gosan, Korea, which is one of the representative background sites in east Asia. As a result, continuous 3-hour average concentrations were obtained for 19 elements including S, Si, Al, Fe, Ca, Cl, Cu, Zn, Ti, K, Mn, Pb, Ni, V, Se, As, Rb, Cr, and Br. Positive matrix factorization (PMF) method was applied to the size-resolved aerosol data sets in order to identify the possible sources and to estimate their contribution to particulate matter mass in each size range. Twelve sources were then resolved in the fine size range (0.07 ˜ 1.15 μm), including continental aerosol, biomass burning, coal combustion, oil heating furnace, residual oil fired boiler, municipal incineration, nonferrous metal source, ferrous metal source, gasoline vehicle, diesel vehicle, copper smelter, and volcanic emission. A newly developed hybrid receptor model, concentration, retention time, and source emission weighted trajectory (CRSWT), was then applied to the source intensities derived from the PMF analysis by incorporating meteorological and source inventory information of the study region in order to suggest the regional information of long-range transported fine aerosol sources. The CRSWT model was able to resolve highly potential source areas and pathways for the fine ambient aerosol at the Gosan background site.

  14. Seasonal variations and sources of ambient fossil and biogenic-derived carbonaceous aerosols based on 14C measurements in Lhasa, Tibet

    Science.gov (United States)

    Huang, Jie; Kang, Shichang; Shen, Chengde; Cong, Zhiyuan; Liu, Kexin; Wang, Wei; Liu, Lichao

    2010-06-01

    A total of 30 samples of total suspended particles were collected at an urban site in Lhasa, Tibet from August 2006 to July 2007 for investigating carbonaceous aerosol features. The fractions of contemporary carbon ( fc) in total carbon (TC) of ambient aerosols are presented using radiocarbon ( 14C) measurements. The value of fc represents the biogenic contribution to TC, as the biosphere releases organic compounds with the present 14C/ 12C level ( fc = 1), whereas 14C has become extinct in anthropogenic emissions of fossil carbon ( fc = 0). The fc values in Lhasa ranging from 0.357 to 0.702, are higher than Beijing and Tokyo, but clearly lower than the rural region of Launceston, which indicates a major biogenic influence in Lhasa. Seasonal variations of fc values corresponded well with variations of pollutants concentrations (e.g. NO 2). Higher fc values appeared in winter indicating carbonaceous aerosol is more dominated by wood burning and incineration of agricultural wastes within this season. The lower fc values in summer and autumn may be caused by increased diesel and petroleum emissions related to tourism in Lhasa. δ13C values ranged from - 26.40‰ to - 25.10‰, with relative higher values in spring and summer, reflecting the increment of fossil carbon emissions.

  15. Differential optical absorption spectrometer measurement of NO 2, SO 2, O 3, HCHO and aromatic volatile organics in ambient air of Kaohsiung Petroleum Refinery in Taiwan

    Science.gov (United States)

    Chiu, Kong Hwa; Sree, Usha; Hong Tseng, Sen; Wu, Chien-Hou; Lo, Jiunn-Guang

    UV-differential optical absorption spectrometer (DOAS) technique is considered as a promising technique to detect gaseous pollutants and was applied to conduct one-week continuous measurements in the Chinese Petroleum (CPC) refinery plant located in Lin Yuan industrial park of Kaohsiung, Southern Taiwan. With the combination of local meteorological information, including solar radiation, wind direction and speed, the results showed that the concentrations of aromatic compounds and formaldehyde (HCHO) were higher at night while the values of ozone, NO 2 and SO 2 were high during the day. The major source of aromatics was the aromatic extraction unit in the refinery while NO 2 and SO 2 were mainly emitted from chimneys with not very high average concentrations. Formaldehyde concentration was above 50 ppbv during night. There exists an apparent correlation between the variation of ground-level ozone concentration and photochemical reactions. The results indicate that in addition to benzene and toluene, ozone is a deleterious pollutant. The commercial DOAS system provides reliable information on distribution patterns of major air pollutants depending on their concentration levels in ambient air.

  16. Modal Parameter Identification of Offshore Platforms under Ambient Excitation

    Institute of Scientific and Technical Information of China (English)

    Yang Hezhen(杨和振); Li Huajun

    2004-01-01

    This paper intends to identify the modal parameters of an offshore platform under ambient excitation, and to compare the identified results with theoretical solutions. Using ambient sources of excitation to determine the modal characteristics of large civil engineering structures is desirable for several reasons. The forced vibration testing of such structures generally requires a large amount of specialized equipment and makes the tests quite expensive. Also, an automated health monitoring system for a large civil structure will most likely use ambient excitation. The Eigensystem Realization Algorithm (ERA) is applied in conjunctied acceleration information. Finally, offshore platform numerical model gets output response data under ambient excitation. Simulated data from numerical model of an offshore platform under ambient excitation is used for the identification of the system. According to the comparison results, the proposed method is shown to be effective for modal parameter identification under ambient excitation.

  17. Putting a damper on drilling's bad vibrations

    Energy Technology Data Exchange (ETDEWEB)

    Jardine, S. (Sedco forex, Montrouge (France)); Malone, D. (Anadrill, Sugar Land, TX (United States)); Sheppard, M. (Schlumberger Cambridge Research, Cambridge (United Kingdom))

    1994-01-01

    Harmful drilling vibrations are costing the industry dearly. Three main vibration types (axial, torsional and transverse) are explained and its causes discussed. Technology exists to eliminate most vibrations, but requires more systematic deployment than is usual. Hardware that eliminates vibrations is reviewed, including downhole shock measurement, torque feedback shock guards and antiwhirl bits. 9 figs., 11 refs.

  18. Electron kinetic energies from vibrationally promoted surface exoemission: evidence for a vibrational autodetachment mechanism.

    Science.gov (United States)

    LaRue, Jerry L; Schäfer, Tim; Matsiev, Daniel; Velarde, Luis; Nahler, N Hendrik; Auerbach, Daniel J; Wodtke, Alec M

    2011-12-22

    We report kinetic energy distributions of exoelectrons produced by collisions of highly vibrationally excited NO molecules with a low work function Cs dosed Au(111) surface. These measurements show that energy dissipation pathways involving nonadiabatic conversion of vibrational energy to electronic energy can result in electronic excitation of more than 3 eV, consistent with the available vibrational energy. We measured the dependence of the electron energy distributions on the translational and vibrational energy of the incident NO and find a clear positive correlation between final electron kinetic energy and initial vibrational excitation and a weak but observable inverse dependence of electron kinetic energy on initial translational energy. These observations are consistent with a vibrational autodetachment mechanism, where an electron is transferred to NO near its outer vibrational turning point and ejected near its inner vibrational turning point. Within the context of this model, we estimate the NO-to-surface distance for electron transfer. PMID:22112161

  19. Pickin’ up good vibrations

    CERN Multimedia

    Katarina Anthony

    2015-01-01

    In preparation for the civil engineering work on the HL-LHC, vibration measurements were carried out at the LHC’s Point 1 last month. These measurements will help evaluate how civil engineering work could impact the beam, and will provide crucial details about the site’s geological make-up before construction begins.   A seismic truck at Point 1 generated wave-like vibrations measured by EN/MME. From carrying out R&D to produce state-of-the-art magnets to developing innovative, robust materials capable of withstanding beam impact, the HL-LHC is a multi-faceted project involving many groups and teams across CERN’s departments. It was in this framework that the project management mandated CERN's Mechanical and Materials Engineering (EN/MME) group to measure the propagation of vibrations around Point 1. Their question: can civil engineering work for the HL-LHC – the bulk of which is scheduled for LS2 – begin while the LHC is running? Alth...

  20. General vibration monitoring: Experimental hall

    International Nuclear Information System (INIS)

    The reported vibration data were generated from measurements made on the experimental hall floor on December 2, 1992. At the time of the measurements, the ESRF hydrolevel was set-up in the Early Assembly Area (EAA) of the experimental hall and was being used to measure static displacement (settlement) of the floor. The vibration measurement area was on and adjacent to the EAA, in the vicinity of the ESRF hydrolevel test which was in progress. This report summarizes the objectives, instrumentation, measurement locations, observations, and conclusions, and provides selected results in the form of RMS vs. time plots, and power spectral densities from which frequency information can be derived. Measured response amplitudes were within the vibration criteria established for the APS

  1. Psicologia do Ambiente

    OpenAIRE

    Antunes, Dalila; Bernardo, Fátima; Palma-Oliveira, José-Manuel

    2011-01-01

    Na aplicação da Psicologia à área do AMBIENTE importa em primeiro lugar definir o que se entende, neste contexto, por ambiente. O conceito é entendido como toda a envolvente que rodeia o ser humano. Referimo-nos pois ao espaço físico e aos estímulos que nele existem (som, ar, paisagem…), dirigindo-se a Psicologia do Ambiente ao estudo e intervenção sobre a forma como o ambiente influencia o indivíduo ou grupos, e sobre o modo como o comportamento dos indivíduos e grupos influenciam o ambiente...

  2. Vibrational spectroscopy at electrified interfaces

    CERN Document Server

    Wieckowski, Andrzej; Braunschweig, Björn

    2013-01-01

    Reviews the latest theory, techniques, and applications Surface vibrational spectroscopy techniques probe the structure and composition of interfaces at the molecular level. Their versatility, coupled with their non-destructive nature, enables in-situ measurements of operating devices and the monitoring of interface-controlled processes under reactive conditions. Vibrational Spectroscopy at Electrified Interfaces explores new and emerging applications of Raman, infrared, and non-linear optical spectroscopy for the study of charged interfaces. The book draws from hu

  3. Atmosphere and Ambient Space

    DEFF Research Database (Denmark)

    Schmidt, Ulrik

    Atmosphere and Ambient Space This paper explores the relation between atmosphere and ambient space. Atmosphere and ambient space share many salient properties. They are both ontologically indeterminate, constantly varying and formally diffuse and they are both experienced as a subtle, non......-signifying property of a given space. But from a certain point of view, the two concepts also designate quite dissimilar experiences of space. To be ’ambient’ means to surround. Accordingly, ambient space is that space, which surrounds something or somebody. (Gibson 1987: 65) Since space is essentially...... of a surrounding character, all space can thus be described as having a fundamentally ambient character. So what precisely is an ambient space, then? As I will argue in my presentation, ambient space is a sensory effect of spatiality when a space is experienced as being particularly surrounding: a ‘space effect...

  4. Identification of chemical composition and measurement of V, As, Cr and Fe in Yogyakarta ambient air particulate by neutron activation method

    International Nuclear Information System (INIS)

    Activation neutron analysis can be used to identify chemical composition and measure V, As, Cr and Fe contents in Yogyakarta ambient particulate. The air sampling has been done around Yogyakarta city such as: Gg. Narada Gandok around North Ring road (A1 post), Mentri Supeno cross road (A2 post), Purbanegaran GK II (A3 post), Wirobrajan cross road (A4 post), Adisutjipto (A5 post), and in front of Sentul market on JI. Sultan Agung with low volume sampler equipped with AP millipore fiber glass filter. Other places used for air sampling were around PPNY, JI. Babarsari (B1) and Jl. Gejayan (B2) by using high volume sampler equipped with TF A 21133 series filter. The filter was irradiated at Kartini reactor at the average of 1.04 x 1011 n.cm-2.s-1 on January 10, 1995. The V, As, Cr and Fe content in air around Yogyakarta respectively was: 81.5 - 264.9 ng/m3 air; 56.7 - 596.4 ng/m3 air; 30.5 - 153.8 ng/m3 air and 22.4 - 108μg/m3 air. The accuracy of the analysis method was checked by comparing the analysis result to the certificate label of the reference material SRM 1633a. The accuracy was: 21.1%; 13.9%; 7.7% and 13.3% for V, As, Cr and Fe. The V, As, Cr and Fe content in air particulate around Yogyakarta is still the below permissible level of the World Health Organization (WHO) in 1987

  5. Laboratory and Ambient Measurements of Oxidized Organic Compounds in the Gas Phase Using Nitrate Ion Chemical Ionization Coupled with High Resolution Time-of-Flight Mass Spectrometry

    Science.gov (United States)

    Massoli, P.; Stark, H.; Canagaratna, M. R.; Krechmer, J.; Lambe, A. T.; Isaacman-VanWertz, G. A.; Nowak, J. B.; Kimmel, J.; Kroll, J. H.; Jayne, J. T.; Worsnop, D. R.

    2015-12-01

    Chemical Ionization Mass Spectrometry (CIMS) is a widely used technique for molecular level characterization of inorganic and organic gas phase species. Here we present laboratory and ambient measurements of gaseous organic compounds by means of a High Resolution Time-of-Flight Chemical Ionization Mass Spectrometry (HR-ToF-CIMS) using nitrate ion (NO3-) chemistry, which recently has proven capable of selectively detecting oxidized organic molecules in the gas-phase via clustering with NO3- and its high order clusters. Such low and extremely low volatility organic compounds (LVOC, ELVOC) have an important role in particulate phase chemistry and formation of secondary organic aerosol (SOA). The HR-ToF-CIMS was deployed during the Southern Oxidant and Aerosol Study (SOAS) at the forest site in Centreville, AL (June 1 - July 15, 2013), where emissions were dominated by biogenic volatile organic compounds (BVOC), occasionally mixing with anthropogenic emissions. During SOAS, the HR-ToF-CIMS detected oxidation products of both isoprene (typically C5 LVOC) and terpenes (typically C10 ELVOC). The isoprene-related LVOC showed a diurnal cycle with a day time peak, while two groups of terpene ELVOC were identified, one peaking at night and one peaking during the day. Positive Matrix Factorization (PMF) analyses are applied to the dataset to further interpret these observations. The effect of anthropogenic pollution on the biogenic-dominated environment was also investigated during periods of elevated nitrous and sulfur dioxide levels. To further aid in interpretation of the SOAS dataset, oxidized organic molecules were produced via OH and O3 initiated oxidation of biogenic gas-phase precursors in targeted laboratory studies and detected using the HR-ToF-CIMS. Spectra were obtained in these studies over a range of simulated atmospheric conditions.

  6. Modeling and control of vibration in mechanical structures

    OpenAIRE

    Nauclér, Peter

    2005-01-01

    All mechanical systems exhibit vibrational response when exposed to external disturbances. In many engineering applications vibrations are undesirable and may even have harmful effects. Therefore, control of mechanical vibration is an important topic and extensive research has been going on in the field over the years. In active control of vibration, the ability to actuate the system in a controlled manner is incorporated into the structure. Sensors are used to measure the vibrations and seco...

  7. The Book Of Explanation Of Terminology On Noise And Vibration

    International Nuclear Information System (INIS)

    This is the book of explanation of terminology on noise and vibration. It has list of committee members of publish for the book explanation of term of noise and vibration. This book contains the glossary of noise like noise pollution and measurement of noise decibel, logarithm, sound pressure, and the number of vibration, and vibration such as whipping, slamming, sloshing, forced vibration analysis high frequency, acoustic enclosure and damping material.

  8. Monitoring Vibration of A Model of Rotating Machine

    OpenAIRE

    Arko Djajadi; Arsi Azavi; Rusman Rusyadi; Erikson Sinaga

    2012-01-01

    Mechanical movement or motion of a rotating machine normally causes additional vibration. A vibration sensing device must be added to constantly monitor vibration level of the system having a rotating machine, since the vibration frequency and amplitude cannot be measured quantitatively by only sight or touch. If the vibration signals from the machine have a lot of noise, there are possibilities that the rotating machine has defects that can lead to failure. In this experimental research proj...

  9. Theory of vibration protection

    CERN Document Server

    Karnovsky, Igor A

    2016-01-01

    This text is an advancement of the theory of vibration protection of mechanical systems with lumped and distributed parameters. The book offers various concepts and methods of solving vibration protection problems, discusses the advantages and disadvantages of different methods, and the fields of their effective applications. Fundamental approaches of vibration protection, which are considered in this book, are the passive, parametric and optimal active vibration protection. The passive vibration protection is based on vibration isolation, vibration damping and dynamic absorbers. Parametric vibration protection theory is based on the Shchipanov-Luzin invariance principle. Optimal active vibration protection theory is based on the Pontryagin principle and the Krein moment method. The book also contains special topics such as suppression of vibrations at the source of their occurrence and the harmful influence of vibrations on humans. Numerous examples, which illustrate the theoretical ideas of each chapter, ar...

  10. Determination of primary combustion source organic carbon-to-elemental carbon (OC / EC) ratio using ambient OC and EC measurements: secondary OC-EC correlation minimization method

    Science.gov (United States)

    Wu, Cheng; Zhen Yu, Jian

    2016-05-01

    Elemental carbon (EC) has been widely used as a tracer to track the portion of co-emitted primary organic carbon (OC) and, by extension, to estimate secondary OC (SOC) from ambient observations of EC and OC. Key to this EC tracer method is to determine an appropriate OC / EC ratio that represents primary combustion emission sources (i.e., (OC / EC)pri) at the observation site. The conventional approaches include regressing OC against EC within a fixed percentile of the lowest (OC / EC) ratio data (usually 5-20 %) or relying on a subset of sampling days with low photochemical activity and dominated by local emissions. The drawback of these approaches is rooted in its empirical nature, i.e., a lack of clear quantitative criteria in the selection of data subsets for the (OC / EC)pri determination. We examine here a method that derives (OC / EC)pri through calculating a hypothetical set of (OC / EC)pri and SOC followed by seeking the minimum of the coefficient of correlation (R2) between SOC and EC. The hypothetical (OC / EC)pri that generates the minimum R2(SOC,EC) then represents the actual (OC / EC)pri ratio if variations of EC and SOC are independent and (OC / EC)pri is relatively constant in the study period. This Minimum R Squared (MRS) method has a clear quantitative criterion for the (OC / EC)pri calculation. This work uses numerically simulated data to evaluate the accuracy of SOC estimation by the MRS method and to compare with two commonly used methods: minimum OC / EC (OC / ECmin) and OC / EC percentile (OC / EC10 %). Log-normally distributed EC and OC concentrations with known proportion of SOC are numerically produced through a pseudorandom number generator. Three scenarios are considered, including a single primary source, two independent primary sources, and two correlated primary sources. The MRS method consistently yields the most accurate SOC estimation. Unbiased SOC estimation by OC / ECmin and OC / EC10 % only occurs when the left tail of OC / EC

  11. Elimination of flow-induced pulsations and vibrations in a process installation: a combination of on site measurements, calculations and scale modeling

    NARCIS (Netherlands)

    Bokhorst, E. van; Peters, M.C.A.M.

    2008-01-01

    The aim of the work described in this paper was to trace and eliminate vibration sources in a low pressure system with high flow velocities. Considerable vibration on the pipe system between a flashing vessel (6.5 m diameter) and heat-exchangers resulted in fatigue failure, leakage and subsequent sh

  12. Ground motion measurements at the SSC

    International Nuclear Information System (INIS)

    The results of measurements of seismic vibrations in the Exploratory Shaft (at the tunnel depth) and in the ASST building (on the surface) of the Superconducting Super Collider (SSC) site are presented. Spectral and correlation analysis of the data obtained in the frequency band 0.05--1500 Hz is performed. It is found that amplitudes of ambient ground motion are lower than collider requirements, but cultural vibrations are unacceptably large and will cause fast growth of transverse emittance of the SSC beams. The issues of uncorrelated slow ground motion governed by the ''ATL law'' are also discussed on the example of the SSC collider. copyright 1995 American Institute of Physics

  13. Characterisation of an Electrostatic Vibration Harvester

    CERN Document Server

    Sterken, T; Fiorini, P; Puers, R

    2008-01-01

    Harvesting energy from ambient vibration is proposed as an alternative to storage based power supplies for autonomous systems. The system presented converts the mechanical energy of a vibration into electrical energy by means of a variable capacitor, which is polarized by an electret. A lumped element model is used to study the generator and design a prototype. The device has been micromachined in silicon, based on a two-wafer process. The prototype was successfully tested, both using an external polarization source and an electret.

  14. Nonlinear interferometric vibrational imaging

    CERN Document Server

    Marks, D L

    2003-01-01

    Coherent Anti-Stokes Raman Scattering (CARS) processes are ``coherent,'' but the phase of the anti-Stokes radiation is usually lost by most incoherent spectroscopic CARS measurements. We propose a novel Raman microscopy imaging method called Nonlinear Interferometric Vibrational Imaging, which measures Raman spectra by obtaining the temporal anti-Stokes signal through nonlinear interferometry. With a more complete knowledge of the anti-Stokes signal, we show through simulations that a high-resolution Raman spectrum can be obtained of a molecule in a single pulse using broadband radiation. This could be useful for identifying the three-dimensional spatial distribution of molecular species in tissue.

  15. Comparison of System Identification Methods using Ambient Bridge Test Data

    DEFF Research Database (Denmark)

    Andersen, P.; Peeters, B.; Hermans, L.;

    In this paper the performance of four different system identification methods is compared using operational data obtained from an ambient vibration test of the Swiss Z24 highway bridge. The four methods are the frequency domain based peak-picking methods, the polyreference LSCE method, the...

  16. Comparison of System Identification Methods using Ambient Bridge Test Data

    DEFF Research Database (Denmark)

    Andersen, P.; Brincker, Rune; Peeters, B.;

    1999-01-01

    In this paper the performance of four different system identification methods is compared using operational data obtained from an ambient vibration test of the Swiss Z24 highway bridge. The four methods are the frequency domain based peak-picking methods, the polyreference LSCE method, the...

  17. 往复压缩机工艺管道振动分析及消减措施%Vibration Analysis of Reciprocating Compressor Process Pipeline and Eliminating Measures

    Institute of Scientific and Technical Information of China (English)

    董立新; 陈军; 沈磊; 张旭; 胡志毅

    2012-01-01

    This paper has discussed the vibration damage of methanol reciprocating compressor process pipeline, analyzed the reason of abnormal vibration and pointed out the implementation measures of controlling and reducing vibration.lt has achieved good effect in the practical production and effectively ensured the normal operation of CM-203E unit.%通过对甲醇往复压缩机工艺管道振动危害进行讨论,分析引起振动异常的原因,提出抑制和消减振动的实施办法,并在生产实践中取得了良好的效果,有效地保证了解决了CM-203E机组正常的运行.

  18. Shear-wave velocity model of the basin of Santiago de Chile derived from ambient noise measurements for the determination of seismic site conditions and amplification

    Science.gov (United States)

    Pilz, M.; Parolai, S.; Picozzi, M.; Wang, R.; Leyton, F.; Campos, J. A.; Zschau, J.

    2009-12-01

    Generally, the most intense shaking during an earthquake occurs near the rupture fault and decreases with distance away from the fault. However, in a single earthquake the shaking at one site can easily be several times stronger than at another site, even when their distance from the rupture fault is the same. Such site effects are mainly caused by the softness of the soil near the surface and by the thickness of the sediments above hard rock. Seismic site characterization therefore requires usually substantial investment both in time and money for geophysical data acquisition. On the other hand, the necessity of estimating seismic risk for large urban areas like Santiago de Chile wants for at least a first order classification of soil and building vulnerability and therefore needs the definition of proxies. Recently, Wald and Allen (2007) suggested that the slope of topography might serve as a suitable parameter for the estimation of site effects irrespective of the spatial resolution used. Measurements of seismic noise at 146 sites have been carried out in the northern part of Santiago de Chile to determine the fundamental resonance frequency of the sites. The spatial variation in the thickness of the sedimentary cover, known from previous gravimetric investigations, varies significantly over short scale and is roughly retrieved from the peak in the horizontal-to-vertical (H/V) ratios of ambient noise. We inverted the H/V spectra individually for receiving local S-wave velocity profiles. For the inversion procedure, we also used additional geological and geophysical information. The resulting 3D model was derived for a 26 km X 12 km area by interpolation between the single S-wave velocity profiles with a kriging technique and shows good agreement with the few existing velocity profiles but also allows to image the entire area as well as deeper parts of the basin in more detail. Significant variations in the S-wave velocity-depth gradient are found. The wealth of

  19. Theory And Working Of Noise And Vibration

    International Nuclear Information System (INIS)

    This book deals with theory of noise including physical property of noise like term and characteristic of sound, occurrence of sound, characteristic of noise pollution and main cause of occurrence of noise, technique of prevention of noise with noise reduction, construction guide for prevention of noise, and measure of interior noise. It also has the theory of vibration such as an introduction of vibration, and technology of prevention of vibration, official test method of environmental pollution, and summary of protection of the environment.

  20. Large cross section for super energy transfer from hyperthermal atoms to ambient molecules

    Science.gov (United States)

    Ma, Jianqiang; Wilhelm, Michael J.; Smith, Jonathan M.; Dai, Hai-Lung

    2016-04-01

    The experimentally measured cross section for super energy transfer collisions between a hyperthermal H atom and an ambient molecule is presented here. This measurement substantiates an emerging energy transfer mechanism with significant cross section, whereby a major fraction of atomic translational energy is converted into molecular vibrational energy through a transient collision-induced reactive complex. Specifically, using nanosecond time-resolved infrared emission spectroscopy, it is revealed that collisions between hyperthermal hydrogen atoms (with 59 kcal/mol of kinetic energy) and ambient SO2 result in the production of vibrationally highly excited SO2 with >14 000 cm-1 of internal energy. The lower limit of the cross section for this super energy transfer process is determined to be 0.53 ±0.05 Å2, i.e., 2% of all hard-sphere collisions. This cross section is orders of magnitude greater than that predicted by the exponential energy gap law, which is commonly used for describing collisional energy transfer through repulsive interactions.