WorldWideScience

Sample records for aisi 316l stainless

  1. Biomaterial Studies on AISI 316L Stainless Steel after Magnetoelectropolishing

    Directory of Open Access Journals (Sweden)

    Massimiliano Filippi

    2009-03-01

    Full Text Available The polarisation characteristics of the electropolishing process in a magnetic field (MEP – magnetoelectropolishing, in comparison with those obtained under standard/conventional process (EP conditions, have been obtained. The occurrence of an EP plateau has been observed in view of the optimization of MEP process. Up-to-date stainless steel surface studies always indicated some amount of free-metal atoms apart from the detected oxides and hydroxides. Such a morphology of the surface film usually affects the thermodynamic stability and corrosion resistance of surface oxide layer and is one of the most important features of stainless steels. With this new MEP process we can improve metal surface properties by making the stainless steel more resistant to halides encountered in a variety of environments. Furthermore, in this paper the stainless steel surface film study results have been presented. The results of the corrosion research carried out by the authors on the behaviour of the most commonly used material - medical grade AISI 316L stainless steel both in Ringer’s body fluid and in aqueous 3% NaCl solution have been investigated and presented earlier elsewhere, though some of these results, concerning the EIS Nyquist plots and polarization curves are also revealed herein. In this paper an attempt to explain this peculiar performance of 316L stainless steel has been undertaken. The SEM studies, Auger electron spectroscopy (AES and X-ray photoelectron spectroscopy (XPS were performed on 316L samples after three treatments: MP – abrasive polishing (800 grit size, EP – conventional electrolytic polishing, and MEP – magnetoelectropolishing. It has been found that the proposed magnetoelectropolishing (MEP process considerably modifies the morphology and the composition of the surface film, thus leading to improved corrosion resistance of the studied 316L SS.

  2. Linear friction welding of AISI 316L stainless steel

    Energy Technology Data Exchange (ETDEWEB)

    Bhamji, Imran, E-mail: imran.bhamji@postgrad.manchester.ac.uk [Manchester Materials Science Centre, University of Manchester, Grosvenor Street, M1 7HS (United Kingdom); Preuss, Michael [Manchester Materials Science Centre, University of Manchester, Grosvenor Street, M1 7HS (United Kingdom); Threadgill, Philip L. [Formerly with TWI Ltd., Cambridge, UK (now retired) (United Kingdom); Moat, Richard J. [Manchester Materials Science Centre, University of Manchester, Grosvenor Street, M1 7HS (United Kingdom); Addison, Adrian C. [TWI Ltd., Cambridge (United Kingdom); Peel, Matthew J. [University of Bristol, Queens Building, University Walk, Bristol BS8 1TR (United Kingdom)

    2010-12-15

    Research highlights: {yields} Linear friction welding is a feasible process for joining AISI316L. {yields} Most welds had tensile strengths superior to the parent material. {yields} Welding parameters had a significant impact on weld microstructure. {yields} Control of microstructure by controlling welding parameters is a process benefit. - Abstract: Linear friction welding is a solid state joining process established as a niche technology for the joining of aeroengine bladed disks. However, the process is not limited to this application, and therefore the feasibility of joining a common engineering austenitic steel, AISI 316L, has been explored. It was found that mechanically sound linear friction welds could be produced in 316L, with tensile properties in most welds exceeding those of the parent material. The mechanical properties of the welds were also found to be insensitive to relatively large changes in welding parameters. Texture was investigated in one weld using high energy synchrotron X-ray diffraction. Results showed a strong {l_brace}1 1 1{r_brace}< 1 1 2 > type texture at the centre of the weld, which is a typical shear texture in face centre cubic materials. Variations in welding parameters were seen to have a significant impact on the microstructures of welds. This was particularly evident in the variation of the fraction of delta ferrite, in the thermo-mechanically affected zone of the welds, with different process parameters. Analysis of the variation in delta ferrite, with different welding parameters, has produced some interesting insights into heat generation and dissipation during the process. It is hoped that a greater understanding of the process could help to make the parameter optimisation process, when welding 316L as well as other materials, more efficient.

  3. Influence of the surface finishing on electrochemical corrosion characteristics of AISI 316L stainless steel

    Directory of Open Access Journals (Sweden)

    Sylvia Dundeková

    2015-05-01

    Full Text Available Stainless steels from 316 group are very often and successfully uses for medical applications where the good mechanical and chemical properties in combination with non-toxicity of the material assure its safe and long term usage. Corrosion properties of AISI 361L stainless steel are strongly influenced by surface roughness and treatment of the engineering parts (specimens and testing temperature. Electrochemical characteristics of ground, mechanically polished and passivated AISI 316L stainless steel specimens were examined with the aim to identify the polarization resistance evolution due to the surface roughness decrease. Results obtained on mechanically prepared specimens where only natural oxide layer created due to the exposure of the material to the corrosion environment was protecting the materials were compared to the passivated specimens with artificial oxide layer. Also the influence of temperature and stabilization time before measurement were taken into account when discussing the obtained results. Positive influence of decreasing surface roughness was obtained as well as increase of polarization resistance due to the chemical passivation of the surface. Increase of the testing temperature and short stabilization time of the specimen in the corrosion environment were observed negatively influencing corrosion resistance of AISI 316L stainless steel.

  4. Mechanical Properties of Stellite-6 coated AISI 316L Stainless Steel

    Directory of Open Access Journals (Sweden)

    Pushpinderjit Singh

    2016-01-01

    Full Text Available Present paper describes the mechanical properties of Stellite-6 coated AISI 316 L stainless steel. Specimens were coated using Detonation Gun thermal spray process, with different coating thicknesses of Stellite-6 ranging from 50 µm to 150 µm. Afterwards their properties like tensile strength, impact strength and micro hardness were evaluated on the basis of the results obtained from the experimentation. For comparison of substrate and coated material the graphs were plotted. The coated specimens exhibited superior impact strength and microhardness than that of the bare specimens, whereas the tensile strength of coated specimens decreased marginally with the increase in coating thickness.

  5. Surface Nanostructure Formations in an AISI 316L Stainless Steel Induced by Pulsed Electron Beam Treatment

    Directory of Open Access Journals (Sweden)

    Yang Cai

    2015-01-01

    Full Text Available High current pulsed electron beam (HCPEB is an efficient technique for surface modifications of metallic materials. In the present work, the formations of surface nanostructures in an AISI 316L stainless steel induced by direct HCPEB treatment and HCPEB alloying have been investigated. After HCPEB Ti alloying, the sample surface contained a mixture of the ferrite and austenite phases with an average grain size of about 90 nm, because the addition of Ti favors the formation of ferrite. In contrast, electron backscattered diffraction (EBSD analyses revealed no structural refinement on the direct HCPEB treated sample. However, transmission electron microscope (TEM observations showed that fine cells having an average size of 150 nm without misorientations, as well as nanosized carbide particles, were formed in the surface layer after the direct HCPEB treatment. The formation of nanostructures in the 316L stainless steel is therefore attributed to the rapid solidification and the generation of different phases other than the steel substrate in the melted layer.

  6. Analysis of deformation induced martensite in AISI 316L stainless steel

    Energy Technology Data Exchange (ETDEWEB)

    Jagarinec, Darko; Kirbis, Peter; Predan, Jozef; Vuherer, Tomaz; Gubeljak, Nenad [Maribor Univ. (Slovenia). Faculty of Mechanical Engineering

    2016-08-01

    Metastable austenite stainless steel AISI 316L is sensitive to cold deformation, where transformation from austenite to martensite occurred. The bending deformation as the formation process leads to tensile and compression throughout the thickness of the billet. Tensile testing of the specimen causes differences in the true stress-strain along the contraction neck prior to fracture as well. The aim of the paper is to find correlation between microhardness as brief inspection parameters and extension of martensitic transformation. The total equivalent plastic strain extend diagram obtained by numerical simulation of bending was compared with tensile true stress-strain diagram. Results show very good correlation between hardness, true strain and martesite content. Therefore, one can conclude that by hardness measurement, it is possible to measure the level of equivalent plastic strain until ultimate tensile stress as a linear correlation between hardness, true strain and martesite content.

  7. An investigation of the aseptic loosening of an AISI 316L stainless steel hip prosthesis.

    Science.gov (United States)

    Godec, Matjaz; Kocijan, Aleksandra; Dolinar, Drago; Mandrino, Djordje; Jenko, Monika; Antolic, Vane

    2010-08-01

    The total replacement of joints by the implantation of permanently indwelling prosthetic components has been one of the major successes of modern surgery in terms of relieving pain and correcting deformity. However, the aseptic loosening of a prosthetic-joint component is the most common reason for joint-revision surgery. Furthermore, it is thought that wear particles are one of the major contributors to the development and perpetuation of aseptic loosening. The aim of the present study was to identify the factors related to the aseptic loosening of an AISI 316L stainless steel total hip prosthesis. The stem was evaluated by x-ray photoelectron spectroscopy, with polished and rough regions being analyzed in order to establish the differences in the chemical compositions of both regions. Specific areas were examined using scanning electron microscopy with energy dispersive x-ray spectroscopy and light microscopy.

  8. Investigating the correlation between some of the properties of plasma nitrided AISI 316L stainless steel

    Directory of Open Access Journals (Sweden)

    M. Olzon-Dionysio

    2013-01-01

    Full Text Available When AISI 316L stainless steels are submitted to the nitriding process at temperatures lower than 450 °C, a high nitrogen content expanded austenite phase is formed, which shows higher hardness and higher pitting corrosion resistance compared to the untreated material. As a result, this material becomes adequate for biomedical application. The conditions of the nitriding technique, such as gas mixture, pressure, time and temperature, play an important role in some properties of the modified layer, including: thickness, hardness and N concentration along the layer. This paper explores a set of six samples of AISI 316L, nitrided at different times and temperatures, whose properties show important differences. The aim of this research is to investigate the correlation between the nitrided layer thickness (in the range of 0.77 to 11 µm with both X-ray patterns characteristics and hardness measurements, which used two distinct loads. The results of this study show that: whereas the 3.6 gf load was suitable to measure the real hardness for four of the nitrided layers showing thickness ≥ 2.9 µm, the 50 gf load measured a substrate contribution, probably even for the highest thickness, 11 µm. Moreover, analyzing different reflections of the X-ray patterns showed evidence of the clear consistency between the X-Ray depths and the nitrided layer thicknesses: if the layer thickness is lower than the penetration depth of X-rays, two phases (austenite and expanded substrate are present. If the layer thickness is higher, only the austenite is observed. Finally, concerning the citotoxicity property, all the samples, nitrided or not, were approved in the test for biocompatibility, indicating their potential use for biomedical applications.

  9. Martensite transformation induced by deformation and its phase electrochemical behavior for stainless steels AISI 304 and 316L

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    The martensite transformation induced by tensile elongation and its effect on the behavior of phase electrochemistry of AISI 304 and 316L in 3.5% NaCl solution were studied. The results show that the content of ((-martensite in stainless steel 304 increases with the true strain. As ((-martensite content increased, free corrosion potential and pitting potential of stainless steel 304 in 3.5% NaCl solution appeared the change trend of a minimum. It was also found that pitting nucleated preferentially at the phase interfaces between martensite and austenite. There existed apparent difference between electrochemical properties of austenite and of martensite for stainless steel 304 and 316L in 3.5% NaCl solution.

  10. Effect of Surface Treatment on the Surface Characteristics of AISI 316L Stainless Steel

    Science.gov (United States)

    Trigwell, Steve; Selvaduray, Guna

    2005-01-01

    The ability of 316L stainless steel to maintain biocompatibility, which is dependent upon the surface characteristics, is critical to its effectiveness as an implant material. The surfaces of mechanically polished (MP), electropolished (EP) and plasma treated 316L stainless steel coupons were characterized by X-ray Photoelectron Spectroscopy (XPS) and Auger Electron Spectroscopy (AES) for chemical composition, Atomic Force Microscopy for surface roughness, and contact angle measurements for critical surface tension. All surfaces had a Ni concentration that was significantly lower than the bulk concentration of -43%. The Cr content of the surface was increased significantly by electropolishing. The surface roughness was also improved significantly by electropolishing. Plasma treatment had the reverse effect - the surface Cr content was decreased. It was also found that the Cr and Fe in the surface exist in both the oxide and hydroxide states, with the ratios varying according to surface treatment.

  11. Improvement in cavitation erosion resistance of AISI 316L stainless steel by friction stir processing

    Energy Technology Data Exchange (ETDEWEB)

    Hajian, M. [Department of Materials Engineering, Tarbiat Modares University, P.O. Box 14115-143, Tehran (Iran, Islamic Republic of); Abdollah-zadeh, A., E-mail: zadeh@modares.ac.ir [Department of Materials Engineering, Tarbiat Modares University, P.O. Box 14115-143, Tehran (Iran, Islamic Republic of); Rezaei-Nejad, S.S.; Assadi, H. [Department of Materials Engineering, Tarbiat Modares University, P.O. Box 14115-143, Tehran (Iran, Islamic Republic of); Hadavi, S.M.M. [Department of Materials Science and Engineering, MA University of Technology, Tehran (Iran, Islamic Republic of); Chung, K. [Department of Materials Science and Engineering, Research Institute of Advanced Materials, Engineering Research Institute, Seoul National University, Seoul (Korea, Republic of); Shokouhimehr, M. [Department of Chemical Engineering, College of Engineering, Seoul National University, Seoul 151-742 (Korea, Republic of)

    2014-07-01

    Commercial AISI 316L plates with the initial grain size of 14.8 μm were friction stir processed (FSP) with different processing parameters, resulting in two fine-grained microstructures with the grain sizes of 4.6 and 1.7 μm. The cavitation erosion behavior, before and after FSP, was evaluated in terms of incubation time, cumulative mass loss and mean depth of erosion. A separate cavitation erosion test was performed on the transverse cross section of a FSP sample to reveal the effect of grain structure. It was observed that FSP samples, depending on their grain size, are at least 3–6 times more resistant than the base material against cavitation erosion. The improvement in cavitation erosion resistance is attributed to smaller grain structure, lower fraction of twin boundaries, and favorable crystallographic orientation of grains in FSP samples. The finer the grain size, the more cavitation erosion resistance was achieved. Moreover, the microstructures of eroded surfaces were studied using a scanning electron microscope equipped with EBSD, and an atomic force microscope. The mechanisms controlling the cavitation erosion damage in friction stir processed AISI 316L are also discussed.

  12. Austenitic Stainless Steel AISI 316L Corrosion Test Research%奥氏体不锈钢AISI 316L腐蚀试验研究

    Institute of Scientific and Technical Information of China (English)

    王金刚; 刘江涛; 程珊珊

    2014-01-01

    在精对苯二甲酸(PTA)生产中,选取干燥机BM302壳体常用材料奥氏体不锈钢AISI 316L为研究对象,在醋酸环境中,对AISI 316L 受Br-及Cl-作用的电化学极化试验和电化学阻抗试验进行腐蚀性试验研究。试验结果表明,Br-或Cl-浓度的增加都会导致AISI 316L不锈钢腐蚀速率增加、击穿电位降低、腐蚀反应电阻减小,导致其耐腐蚀性能下降,腐蚀加剧。为PTA设备腐蚀的现场监测和设备维护提供参考依据。%In purified terephthalic acid (PTA) production, selected the drying machine BM302 shell commonly use material austenitic stainless steel AISI 316L as the research object. In the acetic acid environment, for corrosive test research of AISI 316L, through Br-and Cl-the role of electrochemical polarization test and electrochemical impedance test. The test results show that Br-or Cl-will lead to the increasing of the concentration of seawater AISI 316L stainless steel corrosion rate increase, breakdown voltage is reduced, and the corrosion reaction resistance decreases, and lead to its corrosion resistance drop, corrosion intensifies. That will provide reference for PTA equipment corrosion field monitoring and equipment maintenance.

  13. Comportamiento del desgaste del flanco en el torneado en seco de alta velocidad del acero AISI 316L//Flank wear behavior in the dry high‐speed turning of AISI 316L stainless steel

    Directory of Open Access Journals (Sweden)

    Yoandrys Morales-Tamayo

    2013-09-01

    Full Text Available El presente estudio experimental se centra en investigar los efectos de los parámetros corte en el desgaste de flanco con dos insertos recubiertos durante el torneado de acabado en seco a altas velocidades del acero inoxidable AISI 316L. Los efectos de los parámetros de corte fueron determinados utilizando un análisis de varianza y de regresión simple. Como principal resultado se obtuvo el efectosignificativo del avance y del tiempo de maquinado en el desgaste del flanco. El inserto de tres capas no sobrepasó el criterio de fin de vida del desgaste, mientras que el inserto de una capa sufrió un desgaste catastrófico para la mayor velocidad de corte. El desgaste del flanco tuvo mejor comportamiento para el avance de 0,08 mm/rev en todas las velocidades empleadas en este estudio.Palabras claves: torneado de alta velocidad, desgaste de flanco, acero inoxidable AISI 316L, estudio experimental, análisis de varianza y regresión.______________________________________________________________________________AbstractThe current experimental study is focused on investigating the effects of cutting parameters on flank wear in two coated carbide inserts during dry high speed finish turning of AISI 316L stainless steel. The effects of cutting parameters were determinate using analysis of variance and simple regression. As a main resulta significant effect of cutting feed and the machining time on flank wear was found. The three coating layers insert did not exceed the criterion of end of life of wear while the insert with one layer suffered a catastrophic wear at the highest cutting speed. The flank wear showed the best performance for the cuttingfeed of 0,08 mm/rev at all the speeds used in the study.Key words: high speed turning; flank wear; AISI 316L stainless steel, experimental study; analysis of variance and regression.

  14. Corrosion and microstructural analysis data for AISI 316L and AISI 347H stainless steels after exposure to a supercritical water environment

    Directory of Open Access Journals (Sweden)

    A. Ruiz

    2016-06-01

    Full Text Available This article presents corrosion data and microstructural analysis data of austenitic stainless steels AISI 316L and AISI 347H exposed to supercritical water (25 MPa, 550 °C with 2000 ppb of dissolved oxygen. The corrosion tests lasted a total of 1200 h but were interrupted at 600 h to allow measurements to be made. The microstructural data have been collected in the grain interior and at grain boundaries of the bulk of the materials and at the superficial oxide layer developed during the corrosion exposure.

  15. Corrosion and microstructural analysis data for AISI 316L and AISI 347H stainless steels after exposure to a supercritical water environment.

    Science.gov (United States)

    Ruiz, A; Timke, T; van de Sande, A; Heftrich, T; Novotny, R; Austin, T

    2016-06-01

    This article presents corrosion data and microstructural analysis data of austenitic stainless steels AISI 316L and AISI 347H exposed to supercritical water (25 MPa, 550 °C) with 2000 ppb of dissolved oxygen. The corrosion tests lasted a total of 1200 h but were interrupted at 600 h to allow measurements to be made. The microstructural data have been collected in the grain interior and at grain boundaries of the bulk of the materials and at the superficial oxide layer developed during the corrosion exposure.

  16. Effects of X-rays Radiation on AISI 304 Stainless Steel Weldings with AISI 316L Filler Material: A Study of Resistance and Pitting Corrosion Behavior

    Directory of Open Access Journals (Sweden)

    Francisco Javier Cárcel-Carrasco

    2016-04-01

    Full Text Available This article investigates the effect of low-level ionizing radiation, namely X-rays, on the micro structural characteristics, resistance, and corrosion resistance of TIG-welded joints of AISI 304 austenitic stainless steel made using AISI 316L filler rods. The welds were made in two different environments: natural atmospheric conditions and a closed chamber filled with inert argon gas. The influence of different doses of radiation on the resistance and corrosion characteristics of the welds is analyzed. Welded material from inert Ar gas chamber TIG showed better characteristics and lesser irradiation damage effects.

  17. Corrosion resistance of multilayer hybrid sol-gel coatings deposited on the AISI 316L austenitic stainless steel

    Science.gov (United States)

    Caballero, Y. T.; Rondón, E. A.; Rueda, L.; Hernández Barrios, C. A.; Coy, A.; Viejo, F.

    2016-02-01

    In the present work multilayer hybrid sol-gel coatings were synthesized on the AISI 316L austenitic stainless steel employed in the fabrication of orthopaedic implants. Hybrid sols were obtained from a mixture of inorganic precursor, TEOS, and organic, GPTMS, using ethanol as solvent, and acetic acid as catalyst. The characterization of the sols was performed using pH measurements, rheological tests and infrared spectroscopy (FTIR) for different ageing times. On the other hand, the coatings were characterized by scanning electron microscopy (SEM), while the corrosion resistance was evaluated using anodic potentiodynamic polarization in SBF solution at 37±2°C. The results confirmed that sol-gel synthesis employing TEOS-GPTMS systems produces uniform and homogeneous coatings, which enhanced the corrosion resistance with regard to the parent alloy. Moreover, corrosion performance was retained after applying more than one layer (multilayer coatings).

  18. TEM and AES investigations of the natural surface nano-oxide layer of an AISI 316L stainless steel microfibre.

    Science.gov (United States)

    Ramachandran, Dhanya; Egoavil, Ricardo; Crabbe, Amandine; Hauffman, Tom; Abakumov, Artem; Verbeeck, Johan; Vandendael, Isabelle; Terryn, Herman; Schryvers, Dominique

    2016-11-01

    The chemical composition, nanostructure and electronic structure of nanosized oxide scales naturally formed on the surface of AISI 316L stainless steel microfibres used for strengthening of composite materials have been characterised using a combination of scanning and transmission electron microscopy with energy-dispersive X-ray, electron energy loss and Auger spectroscopy. The analysis reveals the presence of three sublayers within the total surface oxide scale of 5.0-6.7 nm thick: an outer oxide layer rich in a mixture of FeO.Fe2 O3 , an intermediate layer rich in Cr2 O3 with a mixture of FeO.Fe2 O3 and an inner oxide layer rich in nickel.

  19. Plasma nitriding of AISI 304L and AISI 316L stainless steels: effect of time in the formation of S phase and the chromium nitrides; Nitretacao a plasma dos acos inoxidaveis AISI 304L e AISI 316L: efeito do tempo na formacao da fase S e dos nitretos de cromo

    Energy Technology Data Exchange (ETDEWEB)

    Souza, D.A. de; Barbosa, G.C.; Pinto, F.A.M.; Gontijo, L.C. [Instituto Federal de Educacao, Ciencia e Tecnologia do Espirito Santo - IFES, Vitoria, ES (Brazil); Canal, G.P.; Cunha, A.G., E-mail: disouzam@yahoo.com.br [Universidade Federal do Espirito Santo (UFES), Vitoria, ES (Brazil). Dept. de Fisica

    2009-07-01

    Plasma nitriding can improve hardness and wear resistance of austenitic stainless steels without losses in corrosion resistance. This fact relies on a nitrided layer constituted only by S phase, without chromium nitrides precipitation. In this work, the effect of nitriding time on phases formed on nitrided layer was investigated in two austenitic stainless steels: AISI 304L e AISI 316L. The samples were nitrided at 420 deg C, using a mixture of 60 % N{sub 2} and 40% H{sub 2}, during 5, 7 and 9 hours. It was noted that chromium nitrides were formed on samples of AISI 304L, nitrided for 7 e 9 hours, while all nitrided samples of AISI 316L showed only formation of S phase. The nitrided layers were characterized using optical microscope and x-ray diffraction. (author)

  20. Electrochemical characterization of AISI 316L stainless steel in contact with simulated body fluid under infection conditions.

    Science.gov (United States)

    López, Danián Alejandro; Durán, Alicia; Ceré, Silvia Marcela

    2008-05-01

    Titanium and cobalt alloys, as well as some stainless steels, are among the most frequently used materials in orthopaedic surgery. In industrialized countries, stainless steel devices are used only for temporary implants due to their lower corrosion resistance in physiologic media when compared to other alloys. However, due to economical reasons, the use of stainless steel alloys for permanent implants is very common in developing countries. The implantation of foreign bodies is sometimes necessary in the modern medical practice. However, the complex interactions between the host and the can implant weaken the local immune system, increasing the risk of infections. Therefore, it is necessary to further study these materials as well as the characteristics of the superficial film formed in physiologic media in infection conditions in order to control their potential toxicity due to the release of metallic ions in the human body. This work presents a study of the superficial composition and the corrosion resistance of AISI 316L stainless steel and the influence of its main alloying elements when they are exposed to an acidic solution that simulates the change of pH that occurs when an infection develops. Aerated simulated body fluid (SBF) was employed as working solution at 37 degrees C. The pH was adjusted to 7.25 and 4 in order to reproduce normal body and disease state respectively. Corrosion resistance was measured by means of electrochemical impedance spectroscopy (EIS) and anodic polarization curves.

  1. Surface interactions of a W-DLC-coated biomedical AISI 316L stainless steel in physiological solution.

    Science.gov (United States)

    Antunes, Renato A; de Lima, Nelson Batista; Rizzutto, Márcia de Almeida; Higa, Olga Zazuco; Saiki, Mitiko; Costa, Isolda

    2013-04-01

    The corrosion stability of a W-DLC coated surgical AISI 316L stainless steel in Hanks' solution has been evaluated. Particle induced X-ray emission (PIXE) measurements were performed to evaluate the incorporation of potentially bioactive elements from the physiological solution. The film structure was analyzed by X-ray diffractometry and micro-Raman spectroscopy. The wear behavior was assessed using the sphere-on-disc geometry. The in vitro biocompatibility of the W-DLC film was evaluated by cytotoxicity tests. The corrosion resistance of the stainless steel substrate decreased in the presence of the PVD layer. EIS measurements suggest that this behavior was closely related to the corrosion attack through the coating pores. PIXE measurements revealed the presence of Ca and P in the W-DLC film after immersion in Hanks' solution. This result shows that the PIXE technique can be applied to identify and evaluate the incorporation of bioactive elements by W-DLC films. The film showed good wear resistance and biocompatibility.

  2. Biocompatibility studies of low temperature nitrided and collagen-I coated AISI 316L austenitic stainless steel.

    Science.gov (United States)

    Martinesi, M; Stio, M; Treves, C; Borgioli, F

    2013-06-01

    The biocompatibility of austenitic stainless steels can be improved by means of surface engineering techniques. In the present research it was investigated if low temperature nitrided AISI 316L austenitic stainless steel may be a suitable substrate for bioactive protein coating consisting of collagen-I. The biocompatibility of surface modified alloy was studied using as experimental model endothelial cells (human umbilical vein endothelial cells) in culture. Low temperature nitriding produces modified surface layers consisting mainly of S phase, the supersaturated interstitial solid solution of nitrogen in the austenite lattice, which allows to enhance surface microhardness and corrosion resistance in PBS solution. The nitriding treatment seems to promote the coating with collagen-I, without chemical coupling agents, in respect of the untreated alloy. For biocompatibility studies, proliferation, lactate dehydrogenase levels and secretion of two metalloproteinases (MMP-2 and MMP-9) were determined. Experimental results suggest that the collagen protection may be favourable for endothelial cell proliferation and for the control of MMP-2 release.

  3. Improving the corrosion wear resistance of AISI 316L stainless steel by particulate reinforced Ni matrix composite alloying layer

    Energy Technology Data Exchange (ETDEWEB)

    Xu Jiang; Zhuo Chengzhi; Tao Jie; Liu Linlin [Department of Material Science and Engineering, Nanjing University of Aeronautics and Astronautics, 29 Yudao Street, Nanjing 210016 (China); Jiang Shuyun [Department of Mechanical Engineering, Southeast University, 2 Sipailou, Nanjing 210096 (China)], E-mail: xujiang73@nuaa.edu.cn

    2009-01-07

    In order to overcome the problem of corrosion wear of AISI 316L stainless steel (SS), two kinds of composite alloying layers were prepared by a duplex treatment, consisting of Ni/nano-SiC and Ni/nano-SiO{sub 2} predeposited by brush plating, respectively, and subsequent surface alloying with Ni-Cr-Mo-Cu by a double glow process. The microstructure of the two kinds of nanoparticle reinforced Ni-based composite alloying layers was investigated by means of SEM and TEM. The electrochemical corrosion behaviour of composite alloying layers compared with the Ni-based alloying layer and 316L SS under different conditions was characterized by potentiodynamic polarization test and electrochemical impedance spectroscopy. Results showed that under alloying temperature (1000 deg. C) conditions, amorphous nano-SiO{sub 2} particles still retained the amorphous structure, whereas nano-SiC particles were decomposed and Ni, Cr reacted with SiC to form Cr{sub 6.5}Ni{sub 2.5}Si and Cr{sub 23}C{sub 6}. In static acidic solution, the corrosion resistance of the composite alloying layer with the brush plating Ni/nano-SiO{sub 2} particles interlayer is lower than that of the Ni-based alloying layer. However, the corrosion resistance of the composite alloying layer with the brush plating Ni/nano-SiO{sub 2} particles interlayer is prominently superior to that of the Ni-based alloying layer under acidic flow medium condition and acidic slurry flow condition. The corrosion resistance of the composite alloying layer with the brush plating Ni/nano-SiC particles interlayer is evidently lower than that of the Ni-based alloying layer, but higher than that of 316L SS under all test conditions. The results show that the highly dispersive nano-SiO{sub 2} particles are helpful in improving the corrosion wear resistance of the Ni-based alloying layer, whereas carbides and silicide phase are deleterious to that of the Ni-based alloying layer due to the fact that the preferential removal of the matrix

  4. On the corrosion resistance of AISI 316L-type stainless steel coated with manganese and annealed with flow of oxygen

    Science.gov (United States)

    Savaloni, Hadi; Agha-Taheri, Ensieh; Abdi, Fateme

    2016-06-01

    AISI 316L-type stainless steel was coated with 300-nm-thick Mn thin films and post-annealed at 673 K with a constant flow of oxygen (250 cm3/min). The films crystallographic and morphological structures were analyzed using X-ray diffraction (XRD) and atomic force microscopy (AFM) before corrosion test and scanning electron microscopy (SEM) after corrosion test. Corrosion behavior of the samples in 0.3, 0.5 and 0.6 M NaCl solutions was investigated by means of potentiodynamic and electrochemical impedance spectroscopy (EIS) techniques. Results showed that the corrosion inhibition of annealed Mn/SS316L in all NaCl solutions with different concentrations is higher than that of bare SS316L. A correlation is achieved between the structural variation of the films with the potentiodynamic and EIS corrosion results.

  5. In vitro response of human peripheral blood mononuclear cells to AISI 316L austenitic stainless steel subjected to nitriding and collagen coating treatments.

    Science.gov (United States)

    Stio, Maria; Martinesi, Maria; Treves, Cristina; Borgioli, Francesca

    2015-02-01

    Surface modification treatments can be used to improve the biocompatibility of austenitic stainless steels. In the present research two different modifications of AISI 316L stainless steel were considered, low temperature nitriding and collagen-I coating, applied as single treatment or in conjunction. Low temperature nitriding produced modified surface layers consisting mainly of S phase, which enhanced corrosion resistance in PBS solution. Biocompatibility was assessed using human peripheral blood mononuclear cells (PBMC) in culture. Proliferation, lactate dehydrogenase (LDH) levels, release of cytokines (TNF-α, IL-1β, IL-12, IL-10), secretion of metalloproteinase (MMP)-9 and its inhibitor TIMP-1, and the gelatinolytic activity of MMP-9 were determined. While the 48-h incubation of PBMC with all the sample types did not negatively influence cell proliferation, LDH and MMP-9 levels, suggesting therefore a good biocompatibility, the release of the pro-inflammatory cytokines was always remarkable when compared to that of control cells. However, in the presence of the nitrided and collagen coated samples, the release of the pro-inflammatory cytokine IL-1β decreased, while that of the anti-inflammatory cytokine IL-10 increased, in comparison with the untreated AISI 316L samples. Our results suggest that some biological parameters were ameliorated by these surface treatments of AISI 316L.

  6. Study of carbonitriding thermochemical treatment by plasma screen in active with pressures main austenitic stainless steels AISI 409 and AISI 316L; Estudo do tratamento termoquimico de carbonitretacao por plasma em tela ativa com pressoes variaveis nos acos inoxidaveis austenitico AISI 316L e ferririco AISI 409

    Energy Technology Data Exchange (ETDEWEB)

    Melo, M.S.; Oliveira, A.M.; Leal, V.S.; Sousa, R.R.M. de; Alves Junior, C. [Centro Federal de Educacao Tecnologica do Maranhao (CEFET/MA), Sao Luis, MA (Brazil); Centro Federal de Educacao Tecnologica do Piaui (CEFET/PI), Teresina, PI (Brazil); Universidade Federal do Rio Grande do Norte (DF/UFRN), Natal, RN (Brazil). Dept. de Fisica. Labplasma

    2010-07-01

    The technique called Active Screen Plasma Nitriding (ASPN) is being used as an alternative once it offers several advantages with respect to conventional DC plasma. In this method, the plasma does not form directly in the sample's surface but on a screen, in such a way that undesired effects such as the edge effect is minimized. Stainless steels present not very satisfactory wearing characteristics. However, plasma carbonitriding has been used as to improve its resistance to wearing due to the formation of a fine surface layer with good properties. In this work, samples of stainless steel AISI 316L and AISI 409 were treated at pressures of 2.5 and 5 mbar. After the treatments they were characterized by microhardness, microscopy and Xray diffraction. Microscopy and hardness analysis showed satisfactory layers and toughness in those steels. (author)

  7. Cross-sectional transmission electron microscopy of ultra-fine wires of AISI 316L stainless steel

    Science.gov (United States)

    Wang, H. S.; Wei, R. C.; Huang, C. Y.; Yang, J. R.

    2006-01-01

    Starting with 190?µm diameter wire of 316L stainless steel, ultra-thin wire just 8?µm in diameter has been made and characterized. There was no intermediate heat treatment used in the process of drawing, and the amount of true stain was about 6.3. A specimen preparation method for the cross-sectional transmission electron microscopy (TEM) of ultra-fine wires of 316L stainless steel has been developed. The ultra-fine wire was sandwiched between silicon chips and the bonded assembly then sliced to produce longitudinal and transverse sections of the wire in a form suitable for further processing into electron transparent samples. TEM reveals that the heavily deformed wire consists of nanoscale fine elongated structures along the drawing direction. The diffraction patterns indicate that a substantial amount of austenite has transformed into martensite. The TEM dark field images show nanosized patches of martensite distributed among the debris of austenite along the drawing direction. The evidence strongly suggests that severe deformation leads to mechanical stabilization of austenite against the growth of martensite.

  8. Corrosion Inhibition of AISI 316L and Modified-AISI 630 Stainless Steel by the New Organic Inhibitor [(CH32N]3PSe in Chloride Media:Electrochemical and Physical Study

    Directory of Open Access Journals (Sweden)

    Yafa ZARGOUNI

    2015-04-01

    Full Text Available We evaluate the effect of the Tris-dimethylaminoselenophosphoramide (SeAPon the corrosion inhibition of modified-AISI 630 and AISI 316L stainless steel (SS in 3 wt. % NaCl. The electrochemical behaviors of tested SS samples are investigated before and after adding the Seep into the chloride media by potentiodynamic polarization technique. The adsorption of SeAP onto both SS surfaces is verified by global discharge optical emission spectroscopy (GDOES.  SeAP is found to be a good inhibitor for SS corrosion, especially when added at a concentration of 0.5 wt. %.

  9. Microstructure, Strength, and Fracture Topography Relations in AISI 316L Stainless Steel, as Seen through a Fractal Approach and the Hall-Petch Law

    Directory of Open Access Journals (Sweden)

    Oswaldo Antonio Hilders

    2015-01-01

    Full Text Available The influence of the fracture surface fractal dimension DF and the fractal dimension of grain microstructure DM on the strength of AISI 316L type austenitic stainless steel through the Hall-Petch relation has been studied. The change in complexity experimented by the net of grains, as measured by DM, is translated into the respective fracture surface irregularity through DF, in such a way that the higher the grain size (lower DM values the lower the fracture surface roughness (lower values of DF and the shallower the dimples on the fractured surfaces. The material was heat-treated at 904, 1010, 1095, and 1194°C, in order to develop equiaxed grain microstructures and then fractured by tension at room temperature. The fracture surfaces were analyzed with a scanning electron microscope, DF was determined using the slit-island method, and the values of DM were taken from the literature. The relation between grain size, DM, mechanical properties, and DF, developed for AISI 316L steel, could be generalized and therefore applied to most of the common micrograined metal alloys currently used in many key engineering areas.

  10. Cultures and co-cultures of human blood mononuclear cells and endothelial cells for the biocompatibility assessment of surface modified AISI 316L austenitic stainless steel.

    Science.gov (United States)

    Stio, Maria; Martinesi, Maria; Treves, Cristina; Borgioli, Francesca

    2016-12-01

    Samples of AISI 316L austenitic stainless steel were subjected either to grinding and polishing procedure, or to grinding and then low temperature glow-discharge nitriding treatment, or to grinding, nitriding and subsequently coating with collagen-I. Nitrided samples, even if only ground, show a higher corrosion resistance in PBS solution, in comparison with ground and polished AISI 316L. Biocompatibility was evaluated in vitro by incubating the samples with either peripheral blood mononuclear cells (PBMC) or human umbilical vein endothelial cells (HUVEC), tested separately or in co-culture. HUVEC-PBMC co-culture and co-incubation of HUVEC with PBMC culture medium, after the previous incubation of PBMC with metallic samples, allowed to determine whether the incubation of PBMC with the different samples might affect HUVEC behaviour. Many biological parameters were considered: cell proliferation, release of cytokines, matrix metalloproteinases (MMPs) and sICAM-1, gelatinolytic activity of MMPs, and ICAM-1 protein expression. Nitriding treatment, with or without collagen coating of the samples, is able to ameliorate some of the biological parameters taken into account. The obtained results point out that biocompatibility may be successfully tested in vitro, using cultures of normal human cells, as blood and endothelial cells, but more than one cell line should be used, separately or in co-culture, and different parameters should be determined, in particular those correlated with inflammatory phenomena.

  11. Effects of nitrogen and pulsed mean welding current in AISI 316 austenitic stainless steel solidification cracks; Efecto del nitrogeno y la corriente media pulsada de soldadura en la formacion de grietas de solidificacion en aceros inoxidables AISI 316L

    Energy Technology Data Exchange (ETDEWEB)

    Trevisan, R. E.; Braga, E.; Fals, H. C.

    2002-07-01

    An analysis of the influence of nitrogen concentration in the weld zone and the pulsed mean welding current in the solidification crack formation is presented in this paper. The AISI 316L austenitic stainless steel was employed as the metal base. The welding was done using CC+ pulsed flux cored are welding process and AWS E316L wire type. The tests were conducted using CO{sub 2} shielding gas with four different nitrogen levels (0,5; 10 and 15%) in order to induce different nitrogen weld metal concentrations. The pulsed mean welding current was varied in three levels and the. Transvarestraint tangential strain test was fixed of 5%. The results showed that the solidification cracking decreased as the pulsed mean welding current increase. It was also verified that an increase of the weld zone nitrogen level was associated with a decrease in both the total length of solidification crack and the amount of {delta} ferrite. (AUthor) 20 refs.

  12. Biocompatibility of MIM 316L stainless steel

    Institute of Scientific and Technical Information of China (English)

    ZHU Shai-hong; WANG Guo-hui; ZHAO Yan-zhong; LI Yi-ming; ZHOU Ke-chao; HUANG Bai-yun

    2005-01-01

    To evaluate the bioeompatibility of MIM 316L stainless steel, the percentage of S-period cells were detected by flow cytometry after L929 incubated with extraction of MIM 316L stainless steel, using titanium implant materials of clinical application as the contrast. Both materials were implanted in animal and the histopathological evaluations were carried out. The statistical analyses show that there are no significant differences between two groups (P>0.05), which demonstrates that MIM 316L stainless steel has a good biocompatibility.

  13. The effect of CO{sub 2} laser beam welded AISI 316L austenitic stainless steel on the viability of fibroblast cells, in vitro

    Energy Technology Data Exchange (ETDEWEB)

    Köse, Ceyhun, E-mail: ceyhun.kose@gop.edu.tr [Faculty of Natural Sciences and Engineering, Department of Mechanical Engineering, Gaziosmanpaşa University, Tokat (Turkey); Kaçar, Ramazan, E-mail: rkacar@karabuk.edu.tr [Faculty of Technology Department of Manufacturing Engineering, Karabuk University, Karabuk 78050 (Turkey); Zorba, Aslı Pınar, E-mail: aslipinarzorba@gmail.com [Graduate School of Natural and Applied Sciences, Department of Bioengineering Cell Culture and Tissue Engineering, Yıldız Technical University, Istanbul (Turkey); Bağırova, Melahat, E-mail: mbagir@yildiz.edu.tr [Department of Bioengineering Cell Culture and Tissue Engineering, Yıldız Technical University, Istanbul (Turkey); Allahverdiyev, Adil M., E-mail: adil@yildiz.edu.tr [Department of Bioengineering Cell Culture and Tissue Engineering, Yıldız Technical University, Istanbul (Turkey)

    2016-03-01

    It has been determined by the literature research that there is no clinical study on the in vivo and in vitro interaction of the cells with the laser beam welded joints of AISI 316L biomaterial. It is used as a prosthesis and implant material and that has adequate mechanical properties and corrosion resistance characteristics. Therefore, the interaction of the CO{sub 2} laser beam welded samples and samples of the base metal of AISI 316L austenitic stainless steel with L929 fibroblast cells as an element of connective tissue under in vitro conditions has been studied. To study the effect of the base metal and the laser welded test specimens on the viability of the fibroblast cells that act as an element of connective tissues in the body, they were kept in DMEMF-12 medium for 7, 14, 28 days and 18 months. The viability study was experimentally studied using the MTT method for 7, 14, 28 days. In addition, the direct interaction of the fibroblast cells seeded on 6 different plates with the samples was examined with an inverted microscope. The MTT cell viability experiment was repeated on the cells that were in contact with the samples. The statistical relationship was analyzed using a Tukey test for the variance with the GraphPad statistics software. The data regarding metallic ion release were identified with the ICP-MS method after the laser welded and main material samples were kept in cell culture medium for 18 months. The cell viability of the laser welded sample has been detected to be higher than that of the base metal and the control based on 7th day data. However, the laser welded sample's viability of the fibroblast cells has diminished by time during the test period of 14 and 28 days and base metal shows better viability when compared to the laser welded samples. On the other hand, the base metal and the laser welded sample show better cell viability effect when compared to the control group. According to the ICP-MS results of the main material and

  14. Caracterização microestrutural de soldas dissimilares dos aços ASTM A-508 e AISI 316L Characterization of dissimilar metal weld between low alloy steel ASTM A-508 and 316L stainless steel

    Directory of Open Access Journals (Sweden)

    Luciana Iglésias Lourenço Lima

    2010-06-01

    Full Text Available As soldas dissimilares (dissimilar metal welds - DMWs são utilizadas em diversos segmentos da indústria. No caso específico de usinas nucleares, tais soldas são necessárias para conectar tubulações de aço inoxidável com componentes fabricados em aços baixa liga. Os materiais de adição mais utilizados neste tipo de solda são as ligas de níquel 82 e 182. Este trabalho consistiu na soldagem de uma junta dissimilar de aço baixa liga ASTM A-508 G3 e aço inoxidável austenítico AISI 316L utilizando as ligas de níquel 82 e 182 como metais de adição. A soldagem foi realizada manualmente empregando os processos de soldagem ao arco SMAW (Shielded Metal Arc Welding e GTAW (Gas Tungsten Arc Welding. Os corpos de prova foram caracterizados microestruturalmente utilizando-se microscópio óptico e microscópio eletrônico de varredura com microanálise por dispersão de energia de raios X (EDS e ensaios de microdureza Vickers. Observou-se uma microestrutura constituída de dendritas de austenita com a presença de precipitados com formas e dimensões definidas pelo aporte térmico e pela direção de soldagem. Não houve variação significativa da dureza ao longo da junta soldada, demonstrando a adequação dos parâmetros de soldagem utilizados.The dissimilar metal welds (DMWs are used in several areas of the industries. In the nuclear power plant, this weld using nickel alloy welding wires is used to connect stainless steel pipes to low alloy steel components on the reactor pressured vessels. The filler materials commonly used in this type of weld are nickel alloys 82 and 182.. In this study, dissimilar metal welds composed of low alloy steel ASTM A-508 G3, nickel alloys 82 e 182 as weld metals, and austenitic stainless steel AISI 316L were prepared by manual shielded metal arc welding (SMAW and gas tungsten arc welding techniques (GTAW. Samples were microstructural characterized by optical microscopy and scanning electron microscopy

  15. The effect of CO2 laser beam welded AISI 316L austenitic stainless steel on the viability of fibroblast cells, in vitro.

    Science.gov (United States)

    Köse, Ceyhun; Kaçar, Ramazan; Zorba, Aslı Pınar; Bağırova, Melahat; Allahverdiyev, Adil M

    2016-03-01

    It has been determined by the literature research that there is no clinical study on the in vivo and in vitro interaction of the cells with the laser beam welded joints of AISI 316L biomaterial. It is used as a prosthesis and implant material and that has adequate mechanical properties and corrosion resistance characteristics. Therefore, the interaction of the CO2 laser beam welded samples and samples of the base metal of AISI 316L austenitic stainless steel with L929 fibroblast cells as an element of connective tissue under in vitro conditions has been studied. To study the effect of the base metal and the laser welded test specimens on the viability of the fibroblast cells that act as an element of connective tissues in the body, they were kept in DMEMF-12 medium for 7, 14, 28 days and 18 months. The viability study was experimentally studied using the MTT method for 7, 14, 28 days. In addition, the direct interaction of the fibroblast cells seeded on 6 different plates with the samples was examined with an inverted microscope. The MTT cell viability experiment was repeated on the cells that were in contact with the samples. The statistical relationship was analyzed using a Tukey test for the variance with the GraphPad statistics software. The data regarding metallic ion release were identified with the ICP-MS method after the laser welded and main material samples were kept in cell culture medium for 18 months. The cell viability of the laser welded sample has been detected to be higher than that of the base metal and the control based on 7th day data. However, the laser welded sample's viability of the fibroblast cells has diminished by time during the test period of 14 and 28 days and base metal shows better viability when compared to the laser welded samples. On the other hand, the base metal and the laser welded sample show better cell viability effect when compared to the control group. According to the ICP-MS results of the main material and laser welded

  16. Influences of deposition strategies and oblique angle on properties of AISI316L stainless steel oblique thin-walled part by direct laser fabrication

    Science.gov (United States)

    Wang, Xinlin; Deng, Dewei; Qi, Meng; Zhang, Hongchao

    2016-06-01

    Direct laser fabrication (DLF) developed from laser cladding and rapid prototyping technique has been widely used to fabricate thin-walled parts exhibiting more functions without expending weight and size. Oblique thin-walled parts accompanied with inhomogeneous mechanical properties are common in application. In the present study, a series of AISI316L stainless steel oblique thin-walled parts are successfully produced by DLF, in addition, deposition strategies, microstructure, and mechanical property of the oblique thin-walled parts are investigated. The results show that parallel deposition way is more valuable to fabricate oblique thin-walled part than oblique deposition way, because of the more remarkable properties. The hardness of high side initially increases until the distance to the substrate reaches about 25 mm, and then decreases with the increase of the deposition height. Oblique angle has a positive effect on the tensile property but a negative effect on microstructure, hardness and elongation due to the more tempering time. The maximum average ultimate tensile strength (UTS) and elongation are presented 744.3 MPa and 13.5% when the angle between tensile loading direction and horizontal direction is 45° and 90°, respectively.

  17. Effect of Welding Current and Time on the Microstructure, Mechanical Characterizations, and Fracture Studies of Resistance Spot Welding Joints of AISI 316L Austenitic Stainless Steel

    Science.gov (United States)

    Kianersi, Danial; Mostafaei, Amir; Mohammadi, Javad

    2014-09-01

    This article aims at investigating the effect of welding parameters, namely, welding current and welding time, on resistance spot welding (RSW) of the AISI 316L austenitic stainless steel sheets. The influence of welding current and welding time on the weld properties including the weld nugget diameter or fusion zone, tensile-shear load-bearing capacity of welded materials, failure modes, energy absorption, and microstructure of welded nuggets was precisely considered. Microstructural studies and mechanical properties showed that the region between interfacial to pullout mode transition and expulsion limit is defined as the optimum welding condition. Electron microscopic studies indicated different types of delta ferrite in welded nuggets including skeletal, acicular, and lathy delta ferrite morphologies as a result of nonequilibrium phases, which can be attributed to a fast cooling rate in the RSW process. These morphologies were explained based on Shaeffler, WRC-1992, and pseudo-binary phase diagrams. The optimum microstructure and mechanical properties were achieved with 8-kA welding current and 4-cycle welding time in which maximum tensile-shear load-bearing capacity or peak load of the welded materials was obtained at 8070 N, and the failure mode took place as button pullout with tearing from the base metal. Finally, fracture surface studies indicated that elongated dimples appeared on the surface as a result of ductile fracture in the sample welded in the optimum welding condition.

  18. Impact of the surface roughness of AISI 316L stainless steel on biofilm adhesion in a seawater-cooled tubular heat exchanger-condenser.

    Science.gov (United States)

    García, Sergio; Trueba, Alfredo; Vega, Luis M; Madariaga, Ernesto

    2016-11-01

    The present study evaluated biofilm growth in AISI 316L stainless steel tubes for seawater-cooled exchanger-condensers that had four different arithmetic mean surface roughness values ranging from 0.14 μm to 1.2 μm. The results of fluid frictional resistance and heat transfer resistance regarding biofilm formation in the roughest surface showed increases of 28.2% and 19.1% respectively, compared with the smoothest surface. The biofilm thickness taken at the end of the experiment showed variations of up to 74% between the smoothest and roughest surfaces. The thermal efficiency of the heat transfer process in the tube with the roughest surface was 17.4% greater than that in the tube with the smoothest surface. The results suggest that the finish of the inner surfaces of the tubes in heat exchanger-condensers is critical for improving energy efficiency and avoiding biofilm adhesion. This may be utilised to reduce biofilm adhesion and growth in the design of heat exchanger-condensers.

  19. Fatigue life of AISI 316L stainless steel welded joints, obtained by GMAW; Vida a la fatiga de juntas soldadas del acero inoxidable AISI 316L obtenidas mediante el proceso GMAW

    Energy Technology Data Exchange (ETDEWEB)

    Puchi-Cabrera, E. S.; Saya-Gamboa, R. A.; Barbera-Sosa, J. G. la; Staia, M. H.; Ignoto-Cardinale, V.; Berrios-Ortiz, J. A.; Mesmacque, G.

    2007-07-01

    An investigation has been conducted in order to determine the effect of both the metallic transfer mode (pulsed arc or short circuit) and the O{sub 2} content in the Ar/O{sub 2} gas mixture, of the gas-metal arc welding process (GMAW), on the fatigue life under uniaxial conditions of welded joints of 316L stainless. it has been concluded that the mixture of the protective gases employed in the process could have an important influence on the fatigue life of the welded joints of such steel in two different ways. firstly, through the modification of the radius of curvature at the joint between the welding tow and the base metal and, secondly, through a more pronounced degree of oxidation of the alloying elements induced by a higher O{sub 2} content in the mixture. As far as the metallic transfer mode is concerned, it has been determined that the welded joints obtained under a pulsed arc mode show a greater fatigue life in comparison with the joints obtained under short circuit for both gas mixtures. (Author) 25 refs.

  20. Residual stress in nano-structured stainless steel (AISI 316L) prompted by Xe+ ion bombardment at different impinging angles

    Science.gov (United States)

    Cucatti, S.; Droppa, R.; Figueroa, C. A.; Klaus, M.; Genzel, Ch.; Alvarez, F.

    2016-10-01

    The effect of low energy (316L steel) is reported. The results take into account the influence of the ion incident angle maintaining constant all other bombarding parameters (i.e., ion energy and current density, temperature, and doses). The bombarded surface topography shows that ions prompt the formation of nanometric regular patterns on the surface crystalline grains and stressing the structure. The paper focalizes on the study of the surface residual stress state stemming from the ion bombardment studied by means of the "sin2 ψ" and "Universal Plot" methods. The analysis shows the absence of shear stress in the affected material region and the presence of compressive in-plane residual biaxial stress (˜200 MPa) expanding up to ˜1 μm depth for all the studied samples. Samples under oblique bombardment present higher compressive stress values in the direction of the projected ion beam on the bombarded surface. The absolute value of the biaxial surface stress difference (σ11-σ22) increases on ion impinging angles, a phenomenon associated with the momentum transfer by the ions. The highest stress level was measured for ion impinging angles of 45° ( σ 11 = -380 ± 10 MPa and σ 22 = -320 ± 10 MPa). The different stresses obtained in the studied samples do not affect significantly the formation of characteristic surface patterns.

  1. Metallurgical and Mechanical Research on Dissimilar Electron Beam Welding of AISI 316L and AISI 4340

    Directory of Open Access Journals (Sweden)

    A. R. Sufizadeh

    2016-01-01

    Full Text Available Dissimilar electron beam welding of 316L austenitic stainless steel and AISI 4340 low alloy high strength steel has been studied. Studies are focused on effect of beam current on weld geometry, optical and scanning electron microscopy, X-ray diffraction of the weld microstructures, and heat affected zone. The results showed that the increase of beam current led to increasing depths and widths of the welds. The optimum beam current was 2.8 mA which shows full penetration with minimum width. The cooling rates were calculated for optimum sample by measuring secondary dendrite arm space and the results show that high cooling rates lead to austenitic microstructure. Moreover, the metallography result shows the columnar and equiaxed austenitic microstructures in weld zone. A comparison of HAZ widths depicts the wider HAZ in the 316L side. The tensile tests results showed that the optimum sample fractured from base metal in AISI 316L side with the UTS values is much greater than the other samples. Moreover, the fractography study presents the weld cross sections with dimples resembling ductile fracture. The hardness results showed that the increase of the beam current led to the formation of a wide softening zone as HAZ in AISI 4340 side.

  2. Effect of ferric ions in AISI 316L stainless steel pickling using an environmentally-friendly H{sub 2}SO{sub 4}-HF-H{sub 2}O{sub 2} mixture

    Energy Technology Data Exchange (ETDEWEB)

    Narvaez, L. [Metallurgical Institute, UASLP Avda. Sierra Leona 550, 78210 San Luis Potosi (Mexico); Cano, E.; Bastidas, J.M. [CENIM-National Centre for Metallurgical Research (CSIC) Avda. Gregorio del Amo 8, 28040 Madrid (Spain)

    2003-02-01

    A mixture of hydrogen peroxide, sulphuric and hydrofluoric acids has been used as pickling solution at pH 2.0 for AISI 316L austenitic stainless steel (SS). The stability of the H{sub 2}SO{sub 4}-HF-H{sub 2}O{sub 2} mixture is assessed varying the ferric ions content from 0 to 40 g/L, the temperature from 25 to 60 C, and with and without stirring of the pickling solution. The AISI 316L SS pickling rate at 50 C was 2.6 and 0.2 mg/dm{sup 2} day (mdd) in the absence and presence of 40 g/L ferric ions, respectively. p-toluene sulphonic acid (PTSA) has been used as stabiliser of hydrogen peroxide. (Abstract Copyright [2003], Wiley Periodicals, Inc.) [German] Es ist ein Gemisch mit einem pH-Wert von 2.0 aus Wasserstoffperoxid, Schwefelsaeure und Fluorwasserstoffsaeure als Beizloesung fuer nichtrostenden Stahl AISI 316L angewandt worden. Die Stabilitaet des Gemisches H{sub 2}SO{sub 4}-HF-H{sub 2}O{sub 2} haengt vom Gehalt der dreiwertigen Eisenionen, zwischen 0 und 40 g/L, von der Temperatur, zwischen 25 und 60 C, und von der Ruehrintensitaet der Beizloesung ab. Die Beizgeschwindigkeit des nichtrostenden Stahls AISI 316L bei 50 C lag bei 2.6 bzw. 0.2 mg/dm{sup 2} taeglich (mdd), je nachdem, ob 40 g/L dreiwertige Eisenionen enthalten waren oder nicht. Als Stabilisator des Wasserstoffperoxids ist para-Toluensulfonsaeure (PTSA) eingesetzt worden. (Abstract Copyright [2003], Wiley Periodicals, Inc.)

  3. Influence of temperature on AISI 316L corrosion in phosphoric acid solutions under hydrodynamic conditions

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez-Tovar, R.; Montanes, M.T.; Garcia-Anton, J. [Valencia Univ. Politecnica, Dept. de Ingenieria Quimica y Nuclear. ETSI Industriales, Valencia (Spain); Ben Bachir, A.; Abdelkebir, B.; Elmandoubi, N. [University Mohammed V-Agdal, Lab. Corrosion-Electrochimie, Faculty of Sciences, Rabat (Morocco)

    2009-07-01

    AISI 316L stainless steel, due to its good mechanical properties and corrosion resistance, is widely used in the phosphoric acid industry, including piping lines. However, phosphoric acid (H{sub 3}PO{sub 4}) is a medium-strong acid, and corrosion problems could occur, especially working with concentrated solutions and increasing temperature. Furthermore, fluid flow can increase corrosion rates. The objective of this work is to study the dynamic corrosion of AISI 316L stainless steel in a range of temperature from 25 C to 60 C by means of cyclic potentiodynamic curves. A hydrodynamic circuit was used in order to study dynamic corrosion. The experiments were carried out in an oxygen-free environment at different Reynolds numbers: 1,456, 3,166 and 5,066. The results show that uniform corrosion mechanisms can be expected for AISI 316L stainless steel in 5.5 M H{sub 3}PO{sub 4} solutions, since no hysteresis loop was observed. Moreover, temperature affects the corrosion parameters obtained from the polarization curves. Temperature shifts corrosion potential to nobler values, reduces the passivity region and enhances passivation current density. On the other hand, little influence of Reynolds number was observed on AISI 316L stainless steel corrosion. (authors)

  4. Metal release rate from AISI 316L stainless steel and pure Fe, Cr and Ni into a synthetic biological medium--a comparison.

    Science.gov (United States)

    Herting, G; Wallinder, I Odnevall; Leygraf, C

    2008-09-01

    Metal release rates from stainless steel grade 316L were investigated in artificial lysosomal fluid (ALF), simulating a human inflammatory cell response. The main focus was placed on release rates of main alloying elements using graphite furnace atomic absorption spectroscopy, and changes in surface oxide composition by means of X-ray photoelectron spectroscopy. To emphasise that alloys and pure metals possess totally different intrinsic properties, comparative studies were performed on the pure alloying constituents: iron, nickel and chromium. Significant differences in release rates were observed due to the presence of a passive surface film on stainless steel. Iron and nickel were released at rates more than 300 times lower from the 316L alloy compared with the pure metals whereas the release rate of chromium was similar. Iron was preferentially released compared with nickel and chromium. Immersion in ALF resulted in the gradual enrichment of chromium in the surface film, a small increase of nickel, and the reduction of oxidized iron with decreasing release rates of alloy constituents as a result. As expected, released metals from stainless steel grade 316L were neither in proportion to the bulk alloy composition nor to the surface film composition.

  5. Corrosion resistance of the welded AISI 316L after various surface treatments

    Directory of Open Access Journals (Sweden)

    Tatiana Liptáková

    2014-01-01

    Full Text Available The main aim of this work is to monitor the surface treatment impact on the corrosion resistance of the welded stainless steel AISI 316L to local corrosion forms. The excellent corrosion resistance of austenitic stainless steel is caused by the existence of stable, thin and well adhering passive layer which quality is strongly influenced by welding. Therefore surface treatment of stainless steel is very important with regard to its local corrosion susceptibility Surfaces of welded stainless steel were treated by various mechanical methods (grinding, garnet blasting. Surface properties were studied by SEM, corrosion resistance was evaluated after exposition tests in chlorides environment using weight and metalographic analysis. The experimental outcomes confirmed that the mechanical finishing has a significant effect on the corrosion behavior of welded stainless steel AISI 316L.

  6. Characterization of Plasma Nitrocarburized Layers Produced on AISI 316L Stainless Steel%AISI 316L不锈钢等离子氮碳共渗层的表征

    Institute of Scientific and Technical Information of China (English)

    L. C. Casteletti; F. A. P. Fernandes; A. Lombardi-Neto; C. A. Picon; G. Tremiliosi-Filho; G. E. Totten

    2009-01-01

    Hardness and consequently wear resistance of austenitic stainless steel can be highly increased, without loosing corrosion resistance by producing plasma nitrocarburizing surface layers. In this work, a AISI 316L stainless steel plasma nitrocarburized at 450℃, and the obtained layers were characterized by optical microscopy, micro-hardness and micro-wear tests. It was verified that the layer is composed by chromium nitrides precipitates and essentially expanded austenite nitrogen rich and with hardness around 850 HV. The total average thickness of the layer was about 45 μm, presenting good uniformity. Its wear resistance was much higher than that of the sub-strate.%奥氏体不锈钢通过等离子氮碳共渗可显著提高其表面硬度,从而提高耐磨性而又不损害其抗腐蚀性能.本文采用光学显微镜、显微硬度和微磨损试验对经于450℃等离子氮碳共渗的AISI 316L不锈钢和所获得的渗层进行了表征.结果证明,等离子氮碳共渗层由氮化铬析出相和富氮奥氏体基体组成,其硬度约850 HV;渗层总深度平均约为45 μm,且很均匀;渗层的耐磨性大大高于基体.

  7. Effect of prior cold work on the degree of sensitisation of welded joints of AISI 316L austenitic stainless steel studied by using an electrochemical minicell

    Energy Technology Data Exchange (ETDEWEB)

    De Tiedra, Pilar [Ciencia de los Materiales e Ingenieria Metalurgica, Departamento CMeIM/EGI/ICGF/IM/IPF, Universidad de Valladolid, Escuela de Ingenierias Industriales, Paseo del Cauce 59, Valladolid 47011 (Spain); Martin, Oscar, E-mail: oml@eis.uva.es [Ciencia de los Materiales e Ingenieria Metalurgica, Departamento CMeIM/EGI/ICGF/IM/IPF, Universidad de Valladolid, Escuela de Ingenierias Industriales, Paseo del Cauce 59, Valladolid 47011 (Spain); Garcia, Cristina; Martin, Fernando; Lopez, Manuel [Ciencia de los Materiales e Ingenieria Metalurgica, Departamento CMeIM/EGI/ICGF/IM/IPF, Universidad de Valladolid, Escuela de Ingenierias Industriales, Paseo del Cauce 59, Valladolid 47011 (Spain)

    2012-01-15

    Highlights: Black-Right-Pointing-Pointer Double loop shows greater sensitivity to interdendritic corrosion than single loop. Black-Right-Pointing-Pointer Fusion line sensitisation is lower than that of weld metal for all prior cold works. Black-Right-Pointing-Pointer Heat affected zone sensitisation is maximum at a prior cold work of 10%. Black-Right-Pointing-Pointer Heat affected zone sensitisation Much-Less-Than base material sensitisation for a prior cold work of 20%. - Abstract: This work aims to assess the effect of prior cold work on the degree of sensitisation of each of the four welding zones of welded joints of AISI 316L subjected to post-welding sensitisation. Electrochemical potentiokinetic reactivation and double loop electrochemical potentiokinetic reactivation tests are performed on each of the four zones by using a small-scale electrochemical cell (minicell). The results show that the degree of sensitisation of heat affected zone, which achieves its maximum at a prior cold work level of 10%, is significantly lower than that of base material for a prior cold work of 20%.

  8. Decomposition of Expanded Austenite in AISI 316 L Stainless Steel Nitrided at 450 ℃%450℃渗氮AISI 316 L不锈钢中膨胀奥氏体的分解

    Institute of Scientific and Technical Information of China (English)

    F.A.P.Fernandes; L.C.Casteletti; G.E.Totten; J.Gallego

    2014-01-01

    Expanded austenite (γN ),which can be produced during plasma nitriding of austenitic stainless steels, provides high levels of strength,toughness and corrosion resistance by comparison with traditional nitride layers. However,expanded austenite properties can be lost due to decomposition caused its thermodynamic metastability. In the present work,austenitic stainless AISI 316L steel was plasma nitrided at 450 ℃ for 5 h at 500 Pa and microstructurally characterised by X-ray diffraction (XRD ),and optical and transmission electron microscopy (TEM)which confirmed the presence of fcc expanded austenite with a lattice parameter up to 9.5% larger than untreated austenite.TEM analyses of thin foils showed that fine nitrides were formed in the N layer and some areas were observed with a singular lamellar morphology very similar to the pearlite colonies found in carbon steels. Selected area electron diffraction (SAED)analysis suggests that these areas are composed of bcc ferrite and cubic chromium nitrides produced after a localised decomposition of the expanded austenite layer.Amorphous expanded austenite was observed in some areas of the investigated samples.The occurrence of N decomposition was associated with microsegregation of ferrite stabilisers (Cr,Mo)and depletion of an austenite stabiliser (Ni)in localised regions of the expanded austenite layer.%奥氏体不锈钢等离子渗氮时会形成膨胀奥氏体(γN),其强度、韧性和耐蚀性均高于传统的氮化物层。然而,膨胀奥氏体在热力学上是亚稳的,其性能会因其发生分解而降低。本文对AISI 316L 不锈钢进行了等离子渗氮,工艺为450℃×5 h,压力500 Pa。对渗氮后试样采用XRD、OM和TEM等进行了显微组织表征。试验结果证明了面心立方膨胀奥氏体的存在,其晶格常数比未经渗氮奥氏体增加多达9.5%。薄片试样的TE M分析表明,N层中有细小的氮化物形成,并且发现一些区域呈奇特的

  9. [Study on biocompatibility of MIM 316L stainless steel].

    Science.gov (United States)

    Wang, Guohui; Zhu, Shaihong; Li, Yiming; Zhao, Yanzhong; Zhou, Kechao; Huang, Boyun

    2007-04-01

    This study was aimed to evaluate the biocompatibility of metal powder injection molding (MIM) 316L stainless steel. The percentage of S-period cells was detected by flow cytometry after L929 cells being incubated with extraction of MIM 316L stainless steel, and titanium implant materials for clinical application were used as control. In addition, both materials were implanted in animals and the histopathological evaluations were carried out. The statistical analyses show that there are no significant differences between the two groups (P > 0.05), which demonstrate that MIM 316L stainless steel has good biocompatibility.

  10. Damage mechanism at different transpassive potentials of solution-annealed 316 and 316l stainless steels

    Institute of Scientific and Technical Information of China (English)

    K Morshed Behbahani; M Pakshir; Z Abbasi; P Najafisayar

    2015-01-01

    Electrochemical impedance spectroscopy (EIS), anodic polarization and scanning electron microscopy techniques were used to investigate the damage mechanism in the transpassive potential region of AISI 316 and AISI 316L solution-annealed stainless steels (SS) with different degrees of sensitization. Depending on the DC potential applied during EIS tests, the AC responses in the transpassive region included three different regions:the first one associated with anodic dissolution of the passive layer, the second one contributed to the disso-lution at the area near grain boundaries, and the last one attributed to pitting corrosion. In addition, the fitting results to experimental data showed that as the DC bias during the EIS test increases the charge transfer resistance (Rct) decreases. Moreover, the Rct values decreased as the sensitization temperature increases but the AISI 316L SS samples exhibited a higher resistance to intergranular corrosion than 316 SS samples.

  11. Nanosized controlled surface pretreatment of biometallic alloy 316L stainless steel.

    Science.gov (United States)

    Abdel-Fattah, Tarek M; Loftis, Derek; Mahapatro, Anil

    2011-12-01

    Stainless steel (AISI 316L) is a medical grade stainless steel alloy used extensively in medical devices and in the biomedical field. 316L stainless steel was successfully electropolished via an ecologically friendly and biocompatible ionic liquid (IL) medium based on Vitamin B4 (NB4) and resulting in nanosized surface roughness and topography. Voltammetry and chronoamperometry tests determined optimum polishing conditions for the stainless steel alloy while atomic force microscopy (AFM) and scanning electron microscopy (SEM) provided surface morphology comparisons to benchmark success of each electropolishing condition. Energy dispersive X-ray analysis (EDX) combined with SEM revealed significantly smoother surfaces for each alloy surface while indicating that the constituent metals comprising each alloy effectively electropolished at uniform rates.

  12. Effects of Ti-C:H coating and plasma nitriding treatment on tribological, electrochemical, and biocompatibility properties of AISI 316L.

    Science.gov (United States)

    Kao, W H; Su, Y L; Horng, J H; Zhang, K X

    2016-08-01

    Ti-C:H coatings were deposited on original, nitrided, and polished-nitrided AISI 316L stainless steel substrates using a closed field unbalanced magnetron sputtering system. Sliding friction wear tests were performed in 0.89 wt.% NaCl solution under a load of 30 N against AISI 316L stainless steel, Si3N4, and Ti6Al4V balls, respectively. The electrochemical properties of the various specimens were investigated by means of corrosion tests performed in 0.89 wt.% NaCl solution at room temperature. Finally, the biocompatibility properties of the specimens were investigated by performing cell culturing experiments using purified mouse leukemic monocyte macrophage cells (Raw264.7). In general, the results showed that plasma nitriding followed by Ti-C:H coating deposition provides an effective means of improving the wear resistance, anti-corrosion properties, and biocompatibility performance of AISI 316L stainless steel.

  13. Study of Ce-modified antibacterial 316L stainless steel

    Directory of Open Access Journals (Sweden)

    Yuan Junping

    2012-11-01

    Full Text Available 316L stainless steel is widely used for fashion jewelry, but it can carry a large number of bacteria and bring the risk of infection since the steel has no antimicrobial performance. In this paper, the effects of Ce on the antibacterial property, corrosion resistance and processability of 316L were studied by microscopic observation, thin-film adhering quantitative bacteriostasis, and electrochemical and mechanical tests. The results show that a trace of Ce can distribute uniformly in the matrix of 316L and slightly improve its corrosion resistance in artificial sweat. With an increase in Ce content, the Ce is prone to form clustering, which degrades the corrosion resistance and the processability. The Ce-containing 316L exhibits Hormesis effect against S. aureus. A small Ce addition stimulates the growth of S. aureus. As the Ce content increases, the modified 316L exhibits an improved antibacterial efficacy. The more Ce is added, the better antibacterial capability is achieved. Overall, if the 316L is modified with Ce alone, it is difficult to obtain the optimal combination of corrosion resistance, antibacterial performance and processability. In spite of that, 0.15 wt.%-0.20 wt.% Ce around is inferred to be the best trade-off.

  14. Laser surface modification of 316L stainless steel.

    Science.gov (United States)

    Balla, Vamsi Krishna; Dey, Sangeetha; Muthuchamy, Adiyen A; Janaki Ram, G D; Das, Mitun; Bandyopadhyay, Amit

    2017-02-28

    Medical grade 316L stainless steel was laser surface melted (LSM) using continuous wave Nd-YAG laser in argon atmosphere at 1 and 5 mm/s. The treated surfaces were characterized using electron backscatter diffraction to study the influence of top surface crystallographic orientation and type of grain boundaries on corrosion resistance, wettability, and biocompatibility. The laser scan velocity was found to have a marginal influence on the surface roughness and the type of grain boundaries. However, the crystal orientation density was found to be relatively high in 1 mm/s samples. The LSM samples showed a higher concentration of {101} and {123} planes parallel to the sample surface as well as a higher fraction of low-angle grain boundaries. The LSM samples were found to exhibit better surface wettability and enhanced the viability and proliferation of human fetal osteoblast cells in vitro when compared to the untreated samples. Further, the corrosion protection efficiency of 316L stainless steel was improved up to 70% by LSM in as-processed condition. The increased concentration of {101} and {123} planes on surfaces of LSM samples increases their surface energy, which is believed to be responsible for the improved in vitro cell proliferation. Further, the increased lattice spacing of these planes and high concentration of low-energy grain boundaries in LSM samples would have contributed to the better in vitro corrosion resistance than untreated 316L stainless steel. Our results indicate that LSM can be a potential treatment option for 316L stainless steel-based biomedical devices to improve biocompatibility and corrosion resistance. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2017.

  15. Quantification of fibrinogen adsorption onto 316L stainless steel.

    Science.gov (United States)

    Gettens, Robert T T; Gilbert, Jeremy L

    2007-05-01

    Adsorption of the plasma protein fibrinogen (Fb) onto 316L stainless steel (316L SS) was observed and quantified using both in situ and ex situ atomic force microscopy techniques. Industry standard mechanical and electrochemical polishing techniques were used to prepare bulk alloy 316L SS samples, rendering the surfaces flat enough to directly observe and measure Fb adsorption. The data were analyzed kinetically using a Langmuir model. Largely irreversible adsorption was found on the 316L SS surface with an adsorption rate constant (k(o)) of 1.9 x 10(-4) mL microg(-1) s(-1) using the ex situ method and 1.7 x 10(-4) mL microg(-1) s(-1) using the in situ method. Additionally, protein conformation and assembly orientation on these surfaces were documented, where the adsorption pattern appeared random. Complete area coverage was never obtained. That is, after adsorption for over 5 time constants (5tau), voids in the structure were always observed.

  16. Fabrication of antibacterial and hydrophilic electroless Ni-B coating on 316L stainless steel

    Science.gov (United States)

    Bülbül, Ferhat; Bülbül, Leman Elif

    2016-01-01

    Biomaterial-associated bacterial infection is one of the most common complications with medical vehicles and implants made of stainless steel. A surface coating treatment like electroless Ni-B deposition, a new candidate to be used in a broad range of engineering applications owing to many advantages such as low cost, thickness uniformity, good wear resistance, may improve the antibacterial activity and physical properties of biomedical devices made of stainless steel. In this study, the antibacterial property of the electroless Ni-B film coated on AISI 316L (UNS S31603) stainless steel is basically investigated. Inhibition halo diameter measurement after incubation at 37 °C and 24 h demonstrates the existence of antimicrobial activity of the electroless Ni-B coating deposited on 316L stainless steel over the Escherichia coli test bacteria. The results of X-ray diffraction, scanning electron microscopy, atomic force microscopy and microhardness measurement studies confirms that the coating deposited on the substrate has an uniform amorphous and a harder structure. Besides, the wettability property of the uncoated substrate and the coating was measured as the contact angle of water. The water contact angle reduced about from 97.7 to 69.25°.

  17. Effect of forming technique BixSiyOz coatings obtained by sol- gel and supported on 316L stainless steel

    Science.gov (United States)

    Bautista Ruiz, J.; Olaya Flórez, J.; Aperador, W.

    2016-02-01

    BixSiyOz type coatings via sol-gel synthesized from bismuth nitrate pentahydrate, and tetraethyl orthosilicate as precursors; glacial acetic acid and 2-ethoxyethanol as solvents, and ethanolamine as complexing. The coatings were supported on AISI 316L stainless steel substrate through dip-coating and spin-coating techniques. The study showed that the spin-coating technique is efficient than dip-coating because it allows more dense and homogeneous films.

  18. Effect of Beam Oscillation on Microstructure and Mechanical Properties of AISI 316L Electron Beam Welds

    Science.gov (United States)

    Kar, Jyotirmaya; Roy, Sanat Kumar; Roy, Gour Gopal

    2017-04-01

    The properties of electron beam-welded AISI 316L stainless steel butt joints prepared with and without beam oscillation were evaluated by microstructural analysis, mechanical testing like microhardness measurements, tensile tests at room and elevated temperature 973 K (700 °C), three-point bend, and Charpy impact tests. All joints, irrespective of being prepared with or without beam oscillation, were found to be defect free. Welds produced by beam oscillation exhibited narrower fusion zone (FZ) with lathy ferrite morphology, while the weld without beam oscillation was characterized by wider FZ and skeletal ferrite morphology. During tensile tests at room and elevated temperature 973 K (700 °C), all samples fractured in the base metal (BM) and showed almost the same tensile properties as that of the BM. However, the notch tensile tests at room temperature demonstrated higher strength for joints prepared with the oscillating beam. Besides, face and root bend tests, as well as Charpy impact tests, showed higher bending strength and notch toughness, respectively, for joints prepared with beam oscillation.

  19. Effect of Beam Oscillation on Microstructure and Mechanical Properties of AISI 316L Electron Beam Welds

    Science.gov (United States)

    Kar, Jyotirmaya; Roy, Sanat Kumar; Roy, Gour Gopal

    2017-02-01

    The properties of electron beam-welded AISI 316L stainless steel butt joints prepared with and without beam oscillation were evaluated by microstructural analysis, mechanical testing like microhardness measurements, tensile tests at room and elevated temperature 973 K (700 °C), three-point bend, and Charpy impact tests. All joints, irrespective of being prepared with or without beam oscillation, were found to be defect free. Welds produced by beam oscillation exhibited narrower fusion zone (FZ) with lathy ferrite morphology, while the weld without beam oscillation was characterized by wider FZ and skeletal ferrite morphology. During tensile tests at room and elevated temperature 973 K (700 °C), all samples fractured in the base metal (BM) and showed almost the same tensile properties as that of the BM. However, the notch tensile tests at room temperature demonstrated higher strength for joints prepared with the oscillating beam. Besides, face and root bend tests, as well as Charpy impact tests, showed higher bending strength and notch toughness, respectively, for joints prepared with beam oscillation.

  20. Effects of nitrogen and hydrogen in argon shielding gas on bead profile, delta-ferrite and nitrogen contents of the pulsed GTAW welds of AISI 316L stainless steel

    Energy Technology Data Exchange (ETDEWEB)

    Viyanit, Ekkarut [National Metal and Materials Technology Center (MTEC), Pathaumthani (Thailand). Failure Analysis and Surface Technology Lab; Hartung, Fritz; Lothongkum, Gobboon [Chulalongkom University, Bangkok (Thailand). Dept. of Metallurgical Engineering,; Phakpeetinan, Panyasak; Chianpairot, Amnuysak

    2016-08-01

    The general effects of 1, 2, 3 and 4 vol.-% nitrogen and 1, 5 and 10 vol.-% hydrogen in argon shielding gas on weld bead profile (depth/width ratio: D/W) and the δ-ferrite content of AISI 316L pulsed GTAW welds were investigated. The limits for imperfections for the quality levels of welds were based on ISO 5817 B. The plates with a thickness of 6 mm were welded at the flat position and the bead on plate. Increasing hydrogen content in argon shielding gas increases the D/W ratio. Excessive hydrogen addition to argon shielding gas will result in incompletely filled groove and excessive penetration of weld. Increasing welding speed decreases the weld-metal volume and the D/W ratios. Nitrogen addition to argon shielding gas has no effect on the D/W ratio. The addition of a mixture of nitrogen and hydrogen to argon shielding gas on the D/W ratio does not show any interaction between them. An effect on the D/W ratio can be exclusively observed as a function of hydrogen content. Increasing hydrogen content in argon shielding gas increases the δ-ferrite content of weld metal. Increasing either nitrogen content in shielding gas or welding speed decreases the δ-ferrite content of weld metal. The nitrogen addition increases the weld metal nitrogen content, however, the hydrogen addition leads to a decrease of weld metal nitrogen content.

  1. Fibrinogen adsorption onto 316L stainless steel under polarized conditions.

    Science.gov (United States)

    Gettens, Robert T T; Gilbert, Jeremy L

    2008-04-01

    Adsorption of the plasma protein fibrinogen onto electrically polarized 316L stainless steel was observed and quantified using both in situ and ex situ atomic force microscopy (AFM) techniques. Significant differences in fibrinogen adsorption were observed across voltages. Ex situ studies showed significantly lower area coverage (theta) and height of adsorbed Fb on cathodically polarized surfaces when compared to anodically polarized surfaces. Conformational differences in the protein may explain the distinctions in Fb surface area coverage (theta) and height between the anodic and cathodic cases. In situ studies showed significantly slower kinetics of Fb adsorption onto surfaces below -100 mV (vs. Ag/AgCl) compared to surfaces polarized above -100 mV. Electrochemical current density data showed large charge transfer processes (approximately 1 x 10(-5) to 1 x 10(-4) A/cm(2)) taking place on the 316L SS surfaces at voltages below -100 mV (vs. Ag/AgCl). These relatively large current densities point to flux of ionic species away from the surface as a major source of the reduction in adsorption kinetics rather than just hydrophilic or electrostatic effects.

  2. Magnetic anisotropy of ultrafine 316L stainless steel fibers

    Science.gov (United States)

    Shyr, Tien-Wei; Huang, Shih-Ju; Wur, Ching-Shuei

    2016-12-01

    An as-received 316L stainless steel fiber with a diameter of 20 μm was drawn using a bundle drawing process at room temperature to form ultrafine stainless steel fibers with diameters of 12, 8, and 6 μm. The crystalline phases of the fibers were analyzed using the X-ray diffraction (XRD) profile fitting technique. The grain sizes of γ-austenite and α‧-martensite were reduced to nanoscale sizes after the drawing process. XRD analysis and focused ion beam-scanning electron microscope observations showed that the newly formed α‧-martensitic grains were closely arrayed in the drawing direction. The magnetic property was measured using a superconducting quantum interference device vibrating sample magnetometer. The magnetic anisotropy of the fibers was observed by applying a magnetic field parallel and perpendicular to the fiber axis. The results showed that the microstructure anisotropy including the shape anisotropy, magnetocrystalline anisotropy, and the orientation of the crystalline phases strongly contributed to the magnetic anisotropy.

  3. Barnacle cement: an etchant for stainless steel 316L?

    Science.gov (United States)

    Sangeetha, R; Kumar, R; Doble, M; Venkatesan, R

    2010-09-01

    Localized corrosion of stainless steel beneath the barnacle-base is an unsolved issue for the marine industry. In this work, we clearly bring out for the first time the role of the barnacle cement in acting as an etchant, preferentially etching the grain boundaries, and initiating the corrosion process in stainless steel 316L. The investigations include structural characterization of the cement and corroded region, and also chemical characterization of the corrosion products generated beneath the barnacle-base. Structural characterization studies using scanning electron microscopy (SEM) reveals the morphological changes in the cement structure across the interface of the base-plate and the substrate, modification of the steel surface by the cement and the corrosion pattern beneath the barnacle-base. Fourier transform infrared spectroscopy (FTIR) of the corrosion products show that they are composed of mainly oxides of iron thereby implying that the corrosion is aerobic in nature. A model for the etching and corrosion mechanism is proposed based on our observations.

  4. Mechanical and Electrochemical Characterization of Super-Solidus Sintered Austenitic Stainless Steel (316L)

    Science.gov (United States)

    Muthuchamy, A.; Raja Annamalai, A.; Ranka, Rishabh

    2016-08-01

    The present study compares the mechanical and electrochemical behaviour of austenitic (AISI 316L) stainless steel compacted at various pressures (200, 400 and 600 MPa) and conventionally sintered at super-solidus temperature of 1,400°C. The electrochemical behaviour was investigated in 0.1 N H2SO4 solution by potentiodynamic polarization and electrochemical impedance spectroscopy (EIS). The shrinkage decreased and densification has been increased with increasing pressure. The mechanical and electrochemical behaviour with pressure has been correlated with densification response and microstructure (pore type, volume and morphology). Highest densification ( 92% theoretical) achieved at 600 MPa (compaction pressure) and 1,400°C (sintering temperature) resulted in excellent combination of tensile strength and ductility (456 ± 40 MPa, 25 ± 1.1%), while showing excellent corrosion resistance (0.1 mmpy or 4.7 mpy).

  5. Inhalation toxicity of 316L stainless steel powder in relation to bioaccessibility.

    Science.gov (United States)

    Stockmann-Juvala, H; Hedberg, Y; Dhinsa, N K; Griffiths, D R; Brooks, P N; Zitting, A; Wallinder, I Odnevall; Santonen, T

    2013-11-01

    The Globally Harmonized System for Classification and Labelling of Chemicals (GHS) considers metallic alloys, such as nickel (Ni)-containing stainless steel (SS), as mixtures of substances, without considering that alloys behave differently compared to their constituent metals. This study presents an approach using metal release, explained by surface compositional data, for the prediction of inhalation toxicity of SS AISI 316L. The release of Ni into synthetic biological fluids is >1000-fold lower from the SS powder than from Ni metal, due to the chromium(III)-rich surface oxide of SS. Thus, it was hypothesized that the inhalation toxicity of SS is significantly lower than what could be predicted based on Ni metal content. A 28-day inhalation study with rats exposed to SS 316L powder (<4 µm, mass median aerodynamic diameter 2.5-3.0 µm) at concentrations up to 1.0 mg/L showed accumulation of metal particles in the lung lobes, but no signs of inflammation, although Ni metal caused lung toxicity in a similar published study at significantly lower concentrations. It was concluded that the bioaccessible (released) fraction, rather than the elemental nominal composition, predicts the toxicity of SS powder. The study provides a basis for an approach for future validation, standardization and risk assessment of metal alloys.

  6. HTS SQUID application for measuring the magnetic properties of AISI type 316L(N) steel

    Energy Technology Data Exchange (ETDEWEB)

    Park, D.G. E-mail: dgpark@nanum.kaeri.re.kr; Kim, D.W.; Hong, J.H.; Timofeev, V.P.; Kim, C.G

    2000-06-02

    A portable RF HTS SQUID-based susceptometer was used for small-size magnetized sample testing in weak DC (up to 200 A/m) and AC (up to 4 A/m) magnetic fields. The system resolution for the magnetic moment is of the order of 1.6x10{sup -10} A m{sup 2}. The measured DC susceptibility of a tested sample of Gd{sub 88}La{sub 12} agrees well with the value obtained by using a commercial liquid helium susceptometer. The measured volume susceptibility of AISI type 316L(N) steel increases after fatigue due to the microcrack induced by cyclic stress.

  7. Physico-chemical properties and microstructure of hydroxyapatite-316L stainless steel biomaterials

    Institute of Scientific and Technical Information of China (English)

    邹俭鹏; 阮建明; 黄伯云; 刘建本; 周小霞

    2004-01-01

    Sintering shrinkage, compressive strength, bending strength, metallurgical morphology, microstructure and chemical composition diffusion of hydroxyapatite-316L stainless steel(HA-316L SS) composites were investigated. The results show that the sintering shrinkage of HA-316L SS composites decreases from 27.38% to 8.87% for cylinder sample or from 27.18% to 8.62% for cuboid sample with decreasing the volume ratio of HA to 316L SS, which leads to higher sintering activity of HA compared with that of 316L SS. The compressive strength of HA-316L SS composites changes just like parabolic curve (245.3→126.3→202.8 MPa) with reducing the volume ratio of HA to 316L SS. Bending strength increases from 86.3MPa to 124. 2 MPa with increasing the content of 316L SS. Furthermore, comprehensive mechanical properties of 1.0∶3.0 (volume ratio of HA to 316L SS) composite are optimal with compressive strength and bending strength equal to 202.8 MPa and 124.2 MPa, respectively. The microstructure and metallurgical structure vary regularly with the volume ratio of HA to 316L SS. Some chemical reaction takes place at the interface of the composites during sintering.

  8. Development of Pack Cementation Aluminizing Process on Inner Surface of 316L Stainless Steel Tube

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    <正>In order to form the FeAl coatings on the inner surface of the 316L stainless steel tube,the pack cementation aluminizing process is introduced in this paper. The outside diameter,wall thickness and

  9. Long-term stability of self-assembled monolayers on 316L stainless steel.

    Science.gov (United States)

    Kaufmann, C R; Mani, G; Marton, D; Johnson, D M; Agrawal, C M

    2010-04-01

    316L stainless steel (316L SS) has been extensively used for making orthopedic, dental and cardiovascular implants. The use of phosphonic acid self-assembled monolayers (SAMs) on 316L SS has been previously explored for potential biomedical applications. In this study, we have investigated the long-term stability of methyl (-CH(3)) and carboxylic acid (-COOH)-terminated phosphonic acid SAMs on 316L under physiological conditions. The stability of SAMs on mechanically polished and electropolished 316L SS was also investigated as a part of this study. Well-ordered and uniform -CH(3)- and -COOH-terminated SAMs were coated on mechanically polished and electropolished 316L SS surfaces. The long-term stability of SAMs on 316L SS was investigated for up to 28 days in Tris-buffered saline (TBS) at 37 degrees C using x-ray photoelectron spectroscopy, atomic force microscopy and contact angle goniometry. A significant amount of phosphonic acid molecules was desorbed from the 316L SS surfaces within 1 to 7 days of TBS immersion followed by a slow desorption of molecules over the remaining days. The -COOH-terminated SAM was found to be more stable than the -CH(3)-terminated SAM on both mechanically and electropolished surfaces. No significant differences in the desorption behavior of SAMs were observed between mechanically and electropolished 316L SS surfaces.

  10. Surface analysis of localized corrosion of austenitic 316L and duplex 2205 stainless steels in simulated body solutions

    Energy Technology Data Exchange (ETDEWEB)

    Conradi, Marjetka, E-mail: marjetka.conradi@imt.si [Institute of Metals and Technology, Lepi pot 11, 1000 Ljubljana (Slovenia); Schoen, Peter M. [Materials Science and Technology of Polymers and MESA Institute for Nanotechnology, University of Twente, Enschede 7500 AE (Netherlands); Kocijan, Aleksandra; Jenko, M. [Institute of Metals and Technology, Lepi pot 11, 1000 Ljubljana (Slovenia); Vancso, G. Julius [Materials Science and Technology of Polymers and MESA Institute for Nanotechnology, University of Twente, Enschede 7500 AE (Netherlands)

    2011-10-17

    Highlights: {yields} In situ steel surface morphology observations in simulated body solutions. {yields} Pitting, square-like and elliptic-like corrosion products. {yields} Corrosion products' shapes related to the growth of Cr and Fe oxides. {yields} Direct relation of the size of the deposition products to surface roughness. - Abstract: We report on cyclic voltammetry and in situ electrochemical atomic force microscopy (EC-AFM) studies of localized corrosion of duplex 2205 stainless steel (DSS 2205) and austenitic stainless steel of the type AISI 316L in two model solutions, including artificial saliva (AS) and a simulated physiological solution known as - Hank's solution (PS). The AFM topography analysis illustrated the higher corrosion resistance of DSS 2205 steel for the chosen range of electrochemical potentials that were applied to the steel surface in both solutions. In contrast, pitting corrosion was observed at the surface of AISI 316L steel, with the pits becoming more evident, larger and deeper, when the sample was electrochemically treated in the PS. On both surfaces the growth of corrosion products formed during the oxidation process was observed. As a result, depending on the sample's metallurgical structure, different types of oxides covered the surface close to the breakdown potential. We distinguished between the square-like type of oxides on the surface of the DSS 2205, and the AISI 316L with its ellipse-like oxide deposits. The X-ray photoelectron spectroscopy (XPS) revealed the chemical composition of the deposition products, which consisted of two main elements, Fe and Cr. However, the oxides of the alloying elements Ni and Mo were negligible compared to the bulk.

  11. Enhancement of cavitation erosion resistance of 316 L stainless steel by adding molybdenum.

    Science.gov (United States)

    Li, D G; Chen, D R; Liang, P

    2017-03-01

    The influence of Mo on ultrasonic cavitation erosion of 316 L stainless steel in 3.5% NaCl solution were investigated using an ultrasonic cavitation erosion (CE) facility. The morphologies of specimen after cavitation erosion were observed by scanning electron microscopy (SEM). The results showed that the addition of Mo can sharply decrease the mean depth of erosion (MDE) of 316 L SS, implying the increased resistance of cavitation erosion. In order to better understanding the influence of Mo on the cavitation erosion of 316 L SS, the semi-conductive property of passive films on 316 L SS containing different concentrations of Mo were studied by Mott-Schottky plot. Based on Mott-Schottky results and semiconductor physics, a physical model was proposed to explain the effect mechanism of Mo on cavitation erosion of 316 L SS.

  12. Corrosion protection performance of porous strontium hydroxyapatite coating on polypyrrole coated 316L stainless steel.

    Science.gov (United States)

    Gopi, D; Ramya, S; Rajeswari, D; Kavitha, L

    2013-07-01

    Polypyrrole/strontium hydroxyapatite bilayer coatings were achieved on 316L stainless steel (316L SS) by the electropolymerisation of pyrrole from sodium salicylate solution followed by the electrodeposition of porous strontium hydroxyapatite. The formation and the morphology of the bilayer coatings were characterised by Fourier transform infrared spectroscopy (FT-IR) and high resolution scanning electron microscopy (HRSEM), respectively. The corrosion resistance of the coated 316L SS specimens was investigated in Ringer's solution by electrochemical techniques and the results were substantiated with inductively coupled plasma atomic emission spectrometry (ICP-AES). The passive film underneath the polypyrrole layer is effective in protecting 316L SS against corrosion in Ringer's solution. Moreover, we believe that the top porous strontium hydroxyapatite layer can provide potential bioactivity to the 316L SS.

  13. Study of the S phase structure on the AISI 316L steel by X-ray diffraction and Moessbauer spectroscopy; Estudo da estrutura da fase S no aco AISI 316L por difracao de raios X e espectroscopia Moessbauer

    Energy Technology Data Exchange (ETDEWEB)

    Gontijo, L.C. [Centro Federal de Educacao Tecnologica do Espirito Santo, Vitoria, ES (Brazil). Coordenadoria de Ciencia e Tecnologia; Machado, R.; Nascente, P.A.P. [Universidade Federal de Sao Carlos, SP (Brazil). Dept. de Engenharia de Materiais]. E-mail: nascente@power.ufscar.br; Miola, E.J. [Universidade Federal de Sao Carlos, SP (Brazil). Dept. de Fisica; Casteletti, L.C. [Universidade de Sao Paulo, Sao Carlos, SP (Brazil). Dept. de Engenharia de Materiais, Aeronautica e Automobilistica

    2005-07-01

    The plasma-nitriding technology has been employed in the industry with the objective of improving the surface properties of metals and alloys. By using the conventional nitriding process at low temperature, some of the properties of the austenitic stainless steels are enhanced by the formation of the S phase, also called expanded austenite. This phase is formed on the surfaces of the austenitic stainless steels nitrided under certain conditions. In the past years, an extensive research has been carried out for the understanding of the S phase, but some questions remain with no answer or with contradictory explanations. In this work, the AISI 316L steel was plasma-nitrided at 350 and 400 deg C, and the samples were characterized by X-ray diffraction (XRD) and conversion electron Moessbauer spectroscopy (CEMS) in order to investigate the S phase. XRD analysis identified the presence of a distorted cubic structure phase. The layer consists of a distribution of nitrogen austenite with different content of nitrogen, ranging from approximately 10 to 40 at-%, and also {gamma}-Fe{sub 4}N and {epsilon}-Fe{sub 2-3}N phases. Moessbauer spectroscopy corroborates these results, and shows a decrease in nitrogen austenite with the increase in nitriding temperature. This decrease is related to the transformation of the nitrogen austenite to the {gamma}-Fe{sub 4}N phase. (author)

  14. Adhesion of composite carbon/hydroxyapatite coatings on AISI 316L medical steel

    Directory of Open Access Journals (Sweden)

    J. Gawroński

    2009-07-01

    Full Text Available In this paper are contains the results of studies concerning the problems associated with increased of hydroxyapatite (HAp adhesion, manufactured by using Pulse Laser Deposition (PLD method, to the austenitic steel (AISI 316L through the coating of carbon interlayer on it. Carbon coating was deposited by Radio Frequency Plasma Assisted Chemical Vapour Deposition (RF PACVD method.Test results unequivocally showed that the intermediate carbon layer in a determined manner increase the adhesion of hydroxyapatite to the metallic substrate. Obtained results give rise to deal with issues of manufacturing composite bilayer – carbon film/HAp – on ready implants, casted from austenitic cast steel by lost-wax process method as well as in gypsum forms.

  15. Reducing Staphylococcus aureus biofilm formation on stainless steel 316L using functionalized self-assembled monolayers

    Energy Technology Data Exchange (ETDEWEB)

    Kruszewski, Kristen M., E-mail: kruszewskik@duq.edu [Duquesne University, Department of Chemistry and Biochemistry, 600 Forbes Avenue, Pittsburgh, PA 15282 (United States); Nistico, Laura, E-mail: lnistico@wpahs.org [Allegheny General Hospital, Center for Genomic Sciences, Allegheny-Singer Research Institute, 320 East North Avenue, 11th floor, South Tower, Pittsburgh, PA 15212 (United States); Longwell, Mark J., E-mail: mlongwel@wpahs.org [Allegheny General Hospital, Center for Genomic Sciences, Allegheny-Singer Research Institute, 320 East North Avenue, 11th floor, South Tower, Pittsburgh, PA 15212 (United States); Hynes, Matthew J., E-mail: mjhynes@go.wustl.edu [Washington University in St. Louis, Department of Chemistry, One Brookings Drive, St. Louis, MO 63130 (United States); Maurer, Joshua A., E-mail: maurer@wustl.edu [Washington University in St. Louis, Department of Chemistry, One Brookings Drive, St. Louis, MO 63130 (United States); Hall-Stoodley, Luanne, E-mail: L.Hall-Stoodley@soton.ac.uk [Southampton Wellcome Trust Clinical Research Facility/NIHR Respiratory BRU, University of Southampton Faculty of Medicine, Southampton General Hospital, Tremona Road, Southampton, Hampshire SO16 6YD (United Kingdom); Gawalt, Ellen S., E-mail: gawalte@duq.edu [Duquesne University, Department of Chemistry and Biochemistry, McGowan Institute for Regenerative Medicine, 600 Forbes Avenue, Pittsburgh, PA 15282 (United States)

    2013-05-01

    Stainless steel 316L (SS316L) is a common material used in orthopedic implants. Bacterial colonization of the surface and subsequent biofilm development can lead to refractory infection of the implant. Since the greatest risk of infection occurs perioperatively, strategies that reduce bacterial adhesion during this time are important. As a strategy to limit bacterial adhesion and biofilm formation on SS316L, self-assembled monolayers (SAMs) were used to modify the SS316L surface. SAMs with long alkyl chains terminated with hydrophobic (− CH{sub 3}) or hydrophilic (oligoethylene glycol) tail groups were used to form coatings and in an orthogonal approach, SAMs were used to immobilize gentamicin or vancomycin on SS316L for the first time to form an “active” antimicrobial coating to inhibit early biofilm development. Modified SS316L surfaces were characterized using surface infrared spectroscopy, contact angles, MALDI-TOF mass spectrometry and atomic force microscopy. The ability of SAM-modified SS316L to retard biofilm development by Staphylococcus aureus was functionally tested using confocal scanning laser microscopy with COMSTAT image analysis, scanning electron microscopy and colony forming unit analysis. Neither hydrophobic nor hydrophilic SAMs reduced biofilm development. However, gentamicin-linked and vancomycin-linked SAMs significantly reduced S. aureus biofilm formation for up to 24 and 48 h, respectively. - Highlights: ► SS316L was modified with glycol terminated SAMs in order to reduce biofilm growth. ► Antibiotics gentamicin and vancomycin were immobilized on SS316L via SAMs. ► Only the antibiotic modifications reduced biofilm development on SS316L.

  16. Evaluation of Direct Diode Laser Deposited Stainless Steel 316L on 4340 Steel Substrate for Aircraft Landing Gear Application

    Science.gov (United States)

    2010-03-01

    AFRL-RX-WP-TP-2010-4149 EVALUATION OF DIRECT DIODE LASER DEPOSITED STAINLESS STEEL 316L ON 4340 STEEL SUBSTRATE FOR AIRCRAFT LANDING GEAR...March 2010 – 01 March 2010 4. TITLE AND SUBTITLE EVALUATION OF DIRECT DIODE LASER DEPOSITED STAINLESS STEEL 316L ON 4340 STEEL SUBSTRATE FOR...Code) N/A Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std. Z39-18 Evaluation of Direct Diode Laser Deposited Stainless Steel 316L on

  17. Laser Surface Alloying of 316L Stainless Steel with Ru and Ni Mixtures

    Directory of Open Access Journals (Sweden)

    M. B. Lekala

    2012-01-01

    Full Text Available The surfaces of AISI 316L stainless steel were laser alloyed with ruthenium powder and a mixture of ruthenium and nickel powders using a cw Nd:YAG laser set at fixed operating parameters. The microstructure, elemental composition, and corrosion characteristics of the alloyed zone were analyzed using optical and scanning electron microscopy (SEM, energy dispersive X-ray spectroscopy (EDX, and corrosion potential measurements. The depth of alloyed zone was measured using the AxioVision program and found to be approximately 1.8 mm for all the alloyed specimens. Hardness profile measurements through the surface-substrate interface showed a significant increase from 160 HV for the substrate to a maximum of 247 HV for the alloyed layer. The sample laser alloyed with 80 wt% Ni-20 wt% presented the most noble corrosion potential (Ecorr of −0.18 V and the lowest corrosion current density (icorr.

  18. Reducing Staphylococcus aureus biofilm formation on stainless steel 316L using functionalized self-assembled monolayers.

    Science.gov (United States)

    Kruszewski, Kristen M; Nistico, Laura; Longwell, Mark J; Hynes, Matthew J; Maurer, Joshua A; Hall-Stoodley, Luanne; Gawalt, Ellen S

    2013-05-01

    Stainless steel 316L (SS316L) is a common material used in orthopedic implants. Bacterial colonization of the surface and subsequent biofilm development can lead to refractory infection of the implant. Since the greatest risk of infection occurs perioperatively, strategies that reduce bacterial adhesion during this time are important. As a strategy to limit bacterial adhesion and biofilm formation on SS316L, self-assembled monolayers (SAMs) were used to modify the SS316L surface. SAMs with long alkyl chains terminated with hydrophobic (-CH3) or hydrophilic (oligoethylene glycol) tail groups were used to form coatings and in an orthogonal approach, SAMs were used to immobilize gentamicin or vancomycin on SS316L for the first time to form an "active" antimicrobial coating to inhibit early biofilm development. Modified SS316L surfaces were characterized using surface infrared spectroscopy, contact angles, MALDI-TOF mass spectrometry and atomic force microscopy. The ability of SAM-modified SS316L to retard biofilm development by Staphylococcus aureus was functionally tested using confocal scanning laser microscopy with COMSTAT image analysis, scanning electron microscopy and colony forming unit analysis. Neither hydrophobic nor hydrophilic SAMs reduced biofilm development. However, gentamicin-linked and vancomycin-linked SAMs significantly reduced S. aureus biofilm formation for up to 24 and 48 h, respectively.

  19. Intragranular cellular segregation network structure strengthening 316L stainless steel prepared by selective laser melting

    Science.gov (United States)

    Zhong, Yuan; Liu, Leifeng; Wikman, Stefan; Cui, Daqing; Shen, Zhijian

    2016-03-01

    A feasibility study was performed to fabricate ITER In-Vessel components by Selective Laser Melting (SLM) supported by Fusion for Energy (F4E). Almost fully dense 316L stainless steel (SS316L) components were prepared from gas-atomized powder and with optimized SLM processing parameters. Tensile tests and Charpy-V tests were carried out at 22 °C and 250 °C and the results showed that SLM SS316L fulfill the RCC-MR code. Microstructure characterization reveals the presence of hierarchical macro-, micro- and nano-structures in as-built samples that were very different from SS316L microstructures prepared by other established methods. The formation of a characteristic intragranular cellular segregation network microstructure appears to contribute to the increase of yield strength without losing ductility. Silicon oxide nano-inclusions were formed during the SLM process that generated a micro-hardness fluctuation in the building direction. The combined influence of a cellular microstructure and the nano-inclusions constraints the size of ductile dimples to nano-scale. The crack propagation is hindered by a pinning effect that improves the defect-tolerance of the SLM SS316L. This work proves that it was possible to manufacture SS316L with properties suitable for ITER First Wall panels. Further studies on irradiation properties of SLM SS316L and manufacturing of larger real-size components are needed.

  20. Highly porous, low elastic modulus 316L stainless steel scaffold prepared by selective laser melting.

    Science.gov (United States)

    Čapek, Jaroslav; Machová, Markéta; Fousová, Michaela; Kubásek, Jiří; Vojtěch, Dalibor; Fojt, Jaroslav; Jablonská, Eva; Lipov, Jan; Ruml, Tomáš

    2016-12-01

    Recently, porous metallic materials have been extensively studied as candidates for use in the fabrication of scaffolds and augmentations to repair trabecular bone defects, e.g. in surroundings of joint replacements. Fabricating these complex structures by using common approaches (e.g., casting and machining) is very challenging. Therefore, rapid prototyping techniques, such as selective laser melting (SLM), have been investigated for these applications. In this study, we characterized a highly porous (87 vol.%) 316L stainless steel scaffold prepared by SLM. 316L steel was chosen because it presents a biomaterial still widely used for fabrication of joint replacements and, from the practical point of view, use of the same material for fabrication of an augmentation and a joint replacement is beneficial for corrosion prevention. The results are compared to the reported properties of two representative nonporous 316L stainless steels prepared either by SLM or casting and subsequent hot forging. The microstructural and mechanical properties and the surface chemical composition and interaction with the cells were investigated. The studied material exhibited mechanical properties that were similar to those of trabecular bone (compressive modulus of elasticity ~0.15GPa, compressive yield strength ~3MPa) and cytocompatibility after one day that was similar to that of wrought 316L stainless steel, which is a commonly used biomaterial. Based on the obtained results, SLM is a suitable method for the fabrication of porous 316L stainless steel scaffolds with highly porous structures.

  1. Processing and mechanical properties of porous 316L stainless steel for biomedical applications

    Institute of Scientific and Technical Information of China (English)

    Montasser M.DEWIDAR; Khalil A.KHALIL; J. K. LIM

    2007-01-01

    Highly porous 316L stainless steel parts were produced by using a powder metallurgy process, which includes the selective laser sintering(SLS) and traditional sintering. Porous 316L stainless steel suitable for medical applications was successfully fabricated in the porosity range of 40%-50% (volume fraction) by controlling the SLS parameters and sintering behaviour. The porosity of the sintered compacts was investigated as a function of the SLS parameters and the furnace cycle. Compressive stress and elastic modulus of the 316L stainless steel material were determined. The compressive strength was found to be ranging from 21 to 32 MPa and corresponding elastic modulus ranging from 26 to 43 GPa. The present parts are promising for biomedical applications since the optimal porosity of implant materials for ingrowths of new-bone tissues is in the range of 20%-59% (volume fraction) and mechanical properties are matching with human bone.

  2. Inlfuence of Marine Aerobic Bioiflms on Corrosion of 316L Stainless Steel

    Institute of Scientific and Technical Information of China (English)

    Feng-ling XU; Ji-zhou DUAN; Cun-guo LIN; Bao-rong HOU

    2015-01-01

    The inlfuence of marine aerobic bioiflms on the corrosion of 316L stainless steel (SS) in aerated and deaerated seawater was studied by electrochemical impedance spectroscopy (EIS), potentiodynamic polarisation curves, current-potential curves and scanning electron microscopy with energy-dispersive spectroscopy (SEM-EDS). EIS and SEM-EDS results showed that the aero-bic bioiflms inhibited 316L SS corrosion within the test duration. Comparison of results under aerated and deaerated conditions revealed that O2 enhanced the inhibition efifciency of the aerobic bioiflms. This result indicated that living cells were necessary for the aerobic bioiflms to inhibit the corrosion of 316L SS. Polarization curves indicated that the bioiflms mainly inhibited anode ac-tion. Current-potential curves under deaerated conditions showed that electron transfer processes occurred between microorganisms and electrodes. Moreover, 316L SS as an electron acceptor was protected from corrosion.

  3. Effect of the La alloying addition on the antibacterial capability of 316L stainless steel.

    Science.gov (United States)

    Yuan, J P; Li, W; Wang, C

    2013-01-01

    316L stainless steel is widely used for fashion jewelry but it can carry a large number of bacteria and cause the potential risk of infection since it has no antimicrobial ability. In this paper, La is used as an alloying addition. The antibacterial capability, corrosion resistance and processability of the La-modified 316L are investigated by microscopic observation, thin-film adhering quantitative bacteriostasis, electrochemical measurement and mechanical test. The investigations reveal that the La-containing 316L exhibits the Hormesis effect against Staphylococcus aureus ATCC 25923 and Escherichia coli DH5α, 0.05 wt.% La stimulates their growth, as La increases, the modified 316L exhibits the improved antibacterial effect. The more amount of La is added, the better antibacterial ability is achieved, and 0.42 wt.% La shows excellent antibacterial efficacy. No more than 0.11 wt.% La addition improves slightly the corrosion resistance in artificial sweat and has no observable impact on the processability of 316L, while a larger La content degrades them. Therefore, the addition of La alone in 316L is difficult to obtain the optimal combination of corrosion resistance, antibacterial capability and processability. In spite of that, 0.15 wt.% La around is inferred to be the trade-off for the best overall performance.

  4. Electrochemical properties of 316L stainless steel with culturing L929 fibroblasts.

    Science.gov (United States)

    Hiromoto, Sachiko; Hanawa, Takao

    2006-08-22

    Potentiodynamic polarization and impedance tests were carried out on 316L stainless steel with culturing murine fibroblast L929 cells to elucidate the corrosion behaviour of 316L steel with L929 cells and to understand the electrochemical interface between 316L steel and cells, respectively. Potential step test was carried out on 316L steel with type I collagen coating and culturing L929 cells to compare the effects of collagen and L929 cells. The open-circuit potential of 316L steel slightly shifted in a negative manner and passive current density increased with cells, indicating a decrease in the protective ability of passive oxide film. The pitting potential decreased with cells, indicating a decrease in the pitting corrosion resistance. In addition, a decrease in diffusivity at the interface was indicated from the decrease in the cathodic current density and the increase in the diffusion resistance parameter in the impedance test. The anodic peak current in the potential step test decreased with cells and collagen. Consequently, the corrosion resistance of 316L steel decreases with L929 cells. In addition, collagen coating would provide an environment for anodic reaction similar to that with culturing cells.

  5. New route to form micro-pores on 316L stainless steel surface

    Energy Technology Data Exchange (ETDEWEB)

    Ma Xinxin [School of Materials Science and Engineering, Harbin Institute of Technology, Harbin, 150001 (China)], E-mail: maxin@hit.edu.cn; Wang Yujiang; Tang Guangze [School of Materials Science and Engineering, Harbin Institute of Technology, Harbin, 150001 (China); Chen Qingfu [Jiangyin Fasten-PLT Materials Science Co., Ltd (Peier), 998 Changjiang Donglu, Jiangyin, 214434 (China)

    2008-11-15

    In order to seek an effective way for preventing restenosis after coronary stent implantation, a proposal of increasing the amount of loaded drug without changing the size of struts was given. Thereafter, a process of fabricating in-situ formed sub-micro-pores on 316L stainless steel (316L SS) was demonstrated. An aluminum thin film was deposited by magnetron sputtering on a 316L substrate. The aluminum film was then anodized in different acids (0.3 M oxalic and 10 vol.% sulfuric) by regulating direct current power supply. Through an appropriate chemical dissolution, the anodic alumina film was removed and the underlying porous 316L was obtained. The morphology of the porous 316L surface was examined by scanning electron microscope and the composition of the pores was investigated by energy dispersive X-ray analysis. The corrosion behavior of the porous 316L was evaluated by the polarization measurement. The results indicate that the shape and size of pores could be affected evidently by the acids used in anodization. The pores density is found to change with variation of the applied voltage in anodization. The corrosion current of the anodized specimens decrease and the corrosion voltage increase, compared with the untreated specimens.

  6. Electrochemical behavior of SUS316L stainless steel after surface modification

    Institute of Scientific and Technical Information of China (English)

    梁成浩; 郭亮; 陈婉; 刘敬肖

    2003-01-01

    The surface modification for SUS316L stainless steel was carried out by electroplating Rh, ion beam assisted deposition Ta2O5 and sol-gel-derived TiO2. In Tyrodes stimulated body fluid, the surface modified samples were investigated with electrochemical techniques. The results indicate that the electrochemical stability and dissolution are improved significantly after surface modification. Moreover, as to ion beam assisted deposition Ta2O5 and sol-gel-derived TiO2 film, the metals d orbit electron holes filled up by the oxygen electrons make against the adsorption of hydrogen. Thus the cathode process, which is controlled by the hydrogen reduction, is held back. X-ray diffraction analysis of SUS316L stainless steel after surface modification reveal that each method forms the uniform and compact film on SUS316L stainless steel. These films prevent the dissolving of elements and improve passivation property of the SUS316L stainless steel.

  7. Effects of simulated inflammation on the corrosion of 316L stainless steel.

    Science.gov (United States)

    Brooks, Emily K; Brooks, Richard P; Ehrensberger, Mark T

    2017-02-01

    Stainless steel alloys, including 316L, find use in orthopaedics, commonly as fracture fixation devices. Invasive procedures involved in the placement of these devices will provoke a local inflammatory response that produces hydrogen peroxide (H2O2) and an acidic environment surrounding the implant. This study assessed the influence of a simulated inflammatory response on the corrosion of 316L stainless steel. Samples were immersed in an electrolyte representing either normal or inflammatory physiological conditions. After 24h of exposure, electrochemical impedance spectroscopy (EIS) and inductively coupled plasma mass spectroscopy (ICPMS) were used to evaluate differences in corrosion behavior and ion release induced by the inflammatory conditions. Scanning electron microscopy (SEM) and energy-dispersive x-ray spectroscopy (EDX) were used to evaluate surface morphology and corrosion products formed on the sample surface. Inflammatory conditions, involving the presence of H2O2 and an acidic pH, significantly alter the corrosion processes of 316L stainless steel, promoting aggressive and localized corrosion. It is demonstrated that particular consideration should be given to 316L stainless steel implants with crevice susceptible areas (ex. screw-head/plate interface), as those areas may have an increased probability of rapid and aggressive corrosion when exposed to inflammatory conditions.

  8. Resistance microwelding of 316L stainless steel wire to block

    DEFF Research Database (Denmark)

    Friis, Kasper Storgaard; Khan, M.I.; Bay, Niels

    2011-01-01

    The excellent corrosion resistance of low carbon vacuum melted 316 stainless steel coupled with its non-magnetic properties makes it ideal for biomedical applications. The typical joint geometry for microcomponents, such as medical implants, includes joining of fine wire to a larger block. However......, this type of joint has received little attention in the current literature. The present study was conducted to examine the microstructure and mechanical properties of low carbon vacuum melted 316 stainless steel wire welded to a larger block. Results revealed solid state bonding occurring at low currents...

  9. Effects of Thermocapillary Forces during Welding of 316L-Type Wrought, Cast and Powder Metallurgy Austenitic Stainless Steels

    CERN Document Server

    Sgobba, Stefano

    2003-01-01

    The Large Hadron Collider (LHC) is now under construction at the European Organization for Nuclear Research (CERN). This 27 km long accelerator requires 1248 superconducting dipole magnets operating at 1.9 K. The cold mass of the dipole magnets is closed by a shrinking cylinder with two longitudinal welds and two end covers at both extremities of the cylinder. The end covers, for which fabrication by welding, casting or Powder Metallurgy (PM) was considered, are dished-heads equipped with a number of protruding nozzles for the passage of the different cryogenic lines. Structural materials and welds must retain high strength and toughness at cryogenic temperature. AISI 316L-type austenitic stainless steel grades have been selected because of their mechanical properties, ductility, weldability and stability of the austenitic phase against low-temperature spontaneous martensitic transformation. 316LN is chosen for the fabrication of the end covers, while the interconnection components to be welded on the protrud...

  10. [Corrosion of stainless steel 201, 304 and 316L in the simulated sewage pipes reactor].

    Science.gov (United States)

    Bao, Guo-Dong; Zuo, Jian-E; Wang, Ya-Jiao; Gan, Li-Li

    2014-08-01

    The corrosion behavior of stainless steel 201, 304 and 316L which would be used as sewer in-situ rehabilitation materials was studied in the simulated sewage pipes reactor. The corrosion potential and corrosion rate of these three materials were studied by potentiodynamic method on the 7th, 14th, 21st, 56th day under two different conditions which were full immersion condition or batch immersion condition with a 2-day cycle. The electrode process was studied by Electrochemical Impedance Spectroscopy (EIS) on the 56th day. The microstructure and composition of the corrosion pitting were analyzed by Scanning Electron Microscope (SEM) and Energy Dispersive Spectrometer (EDS) on the 56th day. The results showed that 304 and 316L had much better corrosion resistance than 201 under both conditions. 304 and 316L had much smaller corrosion rate than 201 under both conditions. The corrosion resistance of all three kinds of stainless steel under the batch immersion condition was much better than those under the full immersion condition. The corrosion rate of all three kinds of stainless steel under the batch immersion condition was much smaller than those under the full immersion condition. Point pitting corrosion was formed on the surfaces of 304 and 316L. In comparison, a large area of corrosion was formed in the surface of 201.

  11. Microstructure and Corrosion Resistance of Laser Additively Manufactured 316L Stainless Steel

    Science.gov (United States)

    Trelewicz, Jason R.; Halada, Gary P.; Donaldson, Olivia K.; Manogharan, Guha

    2016-03-01

    Additive manufacturing (AM) of metal alloys to produce complex part designs via powder bed fusion methods such as laser melting promises to be a transformative technology for advanced materials processing. However, effective implementation of AM processes requires a clear understanding of the processing-structure-properties-performance relationships in fabricated components. In this study, we report on the formation of micro and nanoscale structures in 316L stainless steel samples printed by laser AM and their implications for general corrosion resistance. A variety of techniques including x-ray diffraction, optical, scanning and transmission electron microscopy, x-ray fluorescence, and energy dispersive x-ray spectroscopy were employed to characterize the microstructure and chemistry of the laser additively manufactured 316L stainless steel, which are compared with wrought 316L coupons via electrochemical polarization. Apparent segregation of Mo has been found to contribute to a loss of passivity and an increased anodic current density. While porosity will also likely impact the environmental performance (e.g., facilitating crevice corrosion) of AM alloys, this work demonstrates the critical influence of microstructure and heterogeneous solute distributions on the corrosion resistance of laser additively manufactured 316L stainless steel.

  12. Pitting Corrosion of 316L Stainless Steel under Low Stress below Yield Strength

    Institute of Scientific and Technical Information of China (English)

    L(U) Shengjie; CHENG Xuequn; LI Xiaogang

    2012-01-01

    Pitting corrosion of 316L stainless steel (316L SS) under various stress was studied by potentiodynamic polarization,electrochemical impedance spectroscopy (EIS) and Mott-Schottky (M-S) analysis in 3.5% NaCl solution.The results of polarization curves show that,with the increase of the stress,the pitting potentials and the passive current density markedly decrease firstly (180 MPa),and then increase greatly (200 MPa).The corresponding surface morphologies of the samples after the polarization test well correspond to the results.Mott-Schottky analysis proved the least Cl- adsorbed to the surface of passive film with more positive flat potential,indicating that a moderate stress could increase the pitting corrosion resistance of 316L SS in 3.5% NaCl solution.

  13. Estudio de impedancia de la corrosión del acero inoxidable AISI 316L en las regiones pasiva y de picadura

    Directory of Open Access Journals (Sweden)

    Polo Sanz, José Luis

    1999-12-01

    Full Text Available Impedance measurements were performed on an AISI 316L stainless steel immersed in a 5% NaCl solution at room temperature. Some samples were polarized up to the passive and pitting regions, respectively. The Nyquist plots in the rest potential and in the passive region show high impedance with capacitive behaviour. The impedance diagram in the pitting region shows three loops: a capacitive loop at high frequencies, a loop with inductive effects at intermediate frequencies, and a second capacitive response at low frequencies. To validate the impedance data Kramers-Kronig relations were applied in the pitting región.

    Se estudia la corrosión del acero inoxidable AISI 316L en solución de NaCl al 5% y a temperatura ambiente, utilizándose probetas polarizadas hasta las regiones pasiva y de picadura. Se obtuvieron diagramas de impedancia en el potencial de corrosión y en esas dos regiones. Los diagramas de impedancia en el potencial de corrosión y en la región pasiva muestran comportamiento capacitivo. En la región de picadura los diagramas de impedancia presentan tres bucles capacitivos: un bucle capacitivo a altas frecuencias, un bucle con efectos inductivos a frecuencias intermedias y un segundo bucle capacitivo a bajas frecuencias. Se aplicaron las transformadas de Kramers-Kronig a los resultados de impedancia obtenidos en la región de picadura.

  14. Effect of in site strain on passivated property of the 316L stainless steels.

    Science.gov (United States)

    Jinlong, Lv; Tongxiang, Liang; Chen, Wang; Ting, Guo

    2016-04-01

    The effect of the strain of 316L stainless steel on its corrosion resistance in borate buffer solution was investigated by in site tensile test and the electrochemical impedance spectroscopy measurements. It was found that the corrosion resistance of the 316L stainless steel decreased with the increasing of in site strain. The lower corrosion resistance of the stainless steel during in site strain was mainly attributed to the higher doping concentration in passive film. Especially, with the increasing of in site strain, the concentrations of acceptor (i.e., cation vacancies) in the passive films significantly increased. More acceptor concentrations reduced the compactness of the passive film and its corrosion resistance. Moreover, two exponential relationships were found between in site strain and the charge transfer resistance of the passive film and between in site strain and total doping concentrations in passive film, respectively.

  15. Vida a la fatiga de juntas soldadas del acero inoxidable AISI 316L obtenidas mediante el proceso GMAW

    Directory of Open Access Journals (Sweden)

    Puchi-Cabrera, E. S.

    2007-06-01

    Full Text Available An investigation has been conducted in order to determine the effect of both the metallic transfer mode (pulsed arc or short circuit and the O2 content in the Ar/O2 gas mixture, of the gas-metal arc welding process (GMAW, on the fatigue life under uniaxial conditions of welded joints of 316L stainless steel. It has been concluded that the mixture of the protective gases employed in the process could have an important influence on the fatigue life of the welded joints of such steel in two different ways. Firstly, through the modification of the radius of curvature at the joint between the welding toe and the base metal and, secondly, through a more pronounced degree of oxidation of the alloying elements induced by a higher O2 content in the mixture. As far as the metallic transfer mode is concerned, it has been determined that the welded joints obtained under a pulsed arc mode show a greater fatigue life in comparison with the joints obtained under short circuit for both gas mixtures.

    Se ha llevado a cabo una investigación con la finalidad de determinar el efecto, tanto del modo de transferencia metálica (arco pulsado o cortocircuito como del contenido de O2 en la mezcla de gases protectores Ar/O2, del proceso de soldadura a tope mediante arco metálico con protección gaseosa (GMAW, sobre la vida a la fatiga en condiciones uniaxiales de juntas soldadas del acero inoxidable AISI 316L. Dicho trabajo ha permitido concluir que la composición de la mezcla de gases protectores del proceso GMAW pudiera tener una influencia importante en la vida a la fatiga de las juntas soldadas de dicho material, a través de dos formas distintas: primero, mediante la modificación del radio de curvatura entre la raíz del cordón de soldadura y el metal base y, en segundo lugar, a través del mayor grado de oxidación de los elementos de aleación. En cuanto al modo de transferencia metálica, se determinó que las juntas soldadas mediante arco pulsado

  16. Experimental Study on Uniaxial and Multiaxial Strain Cyclic Characteristics and Ratcheting of 316L Stainless Steel

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    An experimental study was carried out on the strain cycliccharacteristics and ratcheting of 316Lstainless steel subjected to uniaxial and multiaxial cyclic loading. The strain cyclic characteristics were researched under the strain-controlled uniaxial tension-compression and multiaxial circular paths of loading. The ratcheting tests were conducted for the stress-controlled uniaxial tensioncompression and multiaxial circular, rhombic and linear paths of loading with different mean stresses, stress amplitudes and histories. The experiment results show that 316L stainless steel features the cyclic hardening, and its strain cyclic characteristics depend on the strain amplitude and its history apparently. The ratcheting of 316L stainless steel depends greatly on the values of mean stress, stress amplitude and their histories. In the meantime, the shape of load path and its history also apparently influence the ratcheting.

  17. Passivation and electrochemical behavior of 316L stainless steel in chlorinated simulated concrete pore solution

    Science.gov (United States)

    Luo, Hong; Su, Huaizhi; Dong, Chaofang; Li, Xiaogang

    2017-04-01

    In this paper, the passivation and electrochemical behavior of 316L stainless steel in chlorinated simulated concrete pore solutions at different pH was evaluated by potentiodynamic measurements, electrochemical impedance spectroscopy. The composition of the passive film and surface morphology were investigated by X-ray photoelectron spectroscopy (XPS), secondary ion mass spectrometry (SIMS), and scanning electron microscopy, respectively. The results reveal that metastable pitting susceptibility, stable pitting corrosion, and composition of the passive film are influenced by pH value. After long time immersion, a bilayer structure passive film can be formed in this environment. The appearance of molybdates on the outermost surface layer, further enhancing the stability of the passive film. Moreover, the good pitting corrosion resistance of 316L stainless steel in simulated concrete pore solution without carbonated is mainly due to the presence of high Cr/Fe ratio and molybdates ions within the passive film.

  18. Oxide Formation In Metal Injection Molding Of 316L Stainless Steel

    Directory of Open Access Journals (Sweden)

    Jang Jin Man

    2015-06-01

    Full Text Available The effects of sintering condition and powder size on the microstructure of MIMed parts were investigated using water-atomized 316L stainless steel powder. The 316L stainless steel feedstock was injected into micro mold with micro features of various shapes and dimensions. The green parts were debound and pre-sintered at 800°C in hydrogen atmosphere and then sintered at 1300°C and 1350°C in argon atmosphere of 5torr and 760torr, respectively. The oxide particles were formed and distributed homogeneously inside the sample except for the outermost region regardless of sintering condition and powder size. The width of layer without oxide particles are increased with decrease of sintering atmosphere pressure and powder size. The fine oxides act as the obstacle on grain growth and the high sintering temperature causes severe grain growth in micro features due to larger amount of heat gain than that in macro ones.

  19. Fe-Mo-B Enhanced Sintering of P/M 316L Stainless Steel

    Institute of Scientific and Technical Information of China (English)

    YANG Xia; GUO Shi-ju

    2008-01-01

    Liquid-phase enhanced sintering of powder metallurgy (P/M) 316L stainless steel by addition of sintering aids was studied. 2%-8% of pre-alloyed Fe-Mo-B powder with two different particle sizes was added as sintering aids, and the specimens were sintered in vacuum at 1 200-1 350 ℃. The results show that the fine Fe-Mo-B powder (5-10 μm) has stronger activated effect. The sintered density increases with the increase in sintering aid content or sintering temperature. Warm compaction has a better effect on the control of dimensional precision of compacts. The prealloyed Fe-Mo-B powder deviated from Mo2FeB2 component can also be sintering aid of P/M 316L stainless steel.

  20. 316L 超低碳不锈钢的焊接性分析%Analysis of the Welding Character of Extra Low Carbon Stainless Steel 316L

    Institute of Scientific and Technical Information of China (English)

    王敏华; 顾天杰

    2015-01-01

    用不同焊接方式和同一焊接方式不同焊口坡度焊接多种316L超低碳不锈钢焊接试板。通过外观观察、 X射线检验、机械性能检验等方法对成品进行分析,掌握了316L材料的焊接性能。结果表明通过采取适当的工艺措施,316L奥氏体不锈钢焊接接头可以避免热裂纹、晶间腐蚀、刀状腐蚀等缺陷。同时验证了316L焊接接头良好的耐蚀性和机械性能。%A variety of extra low carbon stainless steel 316 L welding test plates were made by different welding ways and different weld slope in the same way.Through visual observation, X-ray inspection, mechanical properties test to analyze the products, the welding properties of 316L materials were mastered.The results showed that by adopting the appropriate process measures, welding joint of 316L austenitic stainless steel can prevent hot crack, intergranular corrosion, knife shaped corrosion.At the same time, it was verified that 316L welded joints had good corrosion resistance and mechanical properties.

  1. Improved corrosion resistance of 316L stainless steel by nanocrystalline and electrochemical nitridation in artificial saliva solution

    Science.gov (United States)

    Lv, Jinlong; Liang, Tongxiang

    2015-12-01

    The fluoride ion in artificial saliva significantly changed semiconductor characteristic of the passive film formed on the surface of 316L stainless steels. The electrochemical results showed that nanocrystalline α‧-martensite improved corrosion resistance of the stainless steel in a typical artificial saliva compared with coarse grained stainless steel. Moreover, comparing with nitrided coarse grained stainless steel, corrosion resistance of the nitrided nanocrystalline stainless steel was also improved significantly, even in artificial saliva solution containing fluoride ion. The present study showed that the cryogenic cold rolling and electrochemical nitridation improved corrosion resistance of 316L stainless steel for the dental application.

  2. Corrosive Metabolic Activity of Desulfovibrio sp. on 316L Stainless Steel

    Science.gov (United States)

    Arkan, Simge; Ilhan-Sungur, Esra; Cansever, Nurhan

    2016-12-01

    The present study investigated the effects of chemical parameters (SO4 2-, PO4 3-, Cl-, pH) and the contents of extracellular polymeric substances (EPS) regarding the growth of Desulfovibrio sp. on the microbiologically induced corrosion of 316L stainless steel (SS). The experiments were carried out in laboratory-scaled test and control systems. 316L SS coupons were exposed to Desulfovibrio sp. culture over 720 h. The test coupons were removed at specific sampling times for enumeration of Desulfovibrio sp., determination of the corrosion rate by the weight loss measurement method and also for analysis of carbohydrate and protein in the EPS. The chemical parameters of the culture were also established. Biofilm/film formation and corrosion products on the 316L SS surfaces were investigated by scanning electron microscopy and energy-dispersive x-ray spectrometry analyses in the laboratory-scaled systems. It was found that Desulfovibrio sp. led to the corrosion of 316L SS. Both the amount of extracellular protein and chemical parameters (SO4 2- and PO4 3-) of the culture caused an increase in the corrosion of metal. There was a significantly positive relationship between the sessile and planktonic Desulfovibrio sp. counts ( p < 0.01). It was detected that the growth phases of the sessile and planktonic Desulfovibrio sp. were different from each other and the growth phases of the sessile Desulfovibrio sp. vary depending on the subspecies of Desulfovibrio sp. and the type of metal when compared with the other published studies.

  3. In vitro biocompatibility of plasma-aided surface-modified 316L stainless steel for intracoronary stents

    Energy Technology Data Exchange (ETDEWEB)

    Bayram, Cem; Denkbas, Emir Baki [Nanotechnology and Nanomedicine Division, The Institute For Graduate Studies in Science and Engineering, Hacettepe University, 06800, Ankara (Turkey); Mizrak, Alpay Koray [Institute of Materials Science and Nanotechnology, Bilkent University, UNAM, 06800, Ankara (Turkey); Aktuerk, Selcuk [Department of Physics, Mugla University, 48000 Koetekli, Mugla (Turkey); Kursaklioglu, Hurkan; Iyisoy, Atila [Department of Cardiology, School of Medicine, Gulhane Military Medicine Academy, 06018, Ankara (Turkey); Ifran, Ahmet, E-mail: denkbas@hacettepe.edu.t [Department of Hematology, School of Medicine, Gulhane Military Medicine Academy, 06018, Ankara (Turkey)

    2010-10-01

    316L-type stainless steel is a raw material mostly used for manufacturing metallic coronary stents. The purpose of this study was to examine the chemical, wettability, cytotoxic and haemocompatibility properties of 316L stainless steel stents which were modified by plasma polymerization. Six different polymeric compounds, polyethylene glycol, 2-hydroxyethyl methacrylate, ethylenediamine, acrylic acid, hexamethyldisilane and hexamethyldisiloxane, were used in a radio frequency glow discharge plasma polymerization system. As a model antiproliferative drug, mitomycin-C was chosen for covalent coupling onto the stent surface. Modified SS 316L stents were characterized by water contact angle measurements (goniometer) and x-ray photoelectron spectroscopy. C1s binding energies showed a good correlation with the literature. Haemocompatibility tests of coated SS 316L stents showed significant latency (t-test, p < 0.05) with respect to SS 316L and control groups in each test.

  4. In vitro biocompatibility of plasma-aided surface-modified 316L stainless steel for intracoronary stents.

    Science.gov (United States)

    Bayram, Cem; Mizrak, Alpay Koray; Aktürk, Selçuk; Kurşaklioğlu, Hurkan; Iyisoy, Atila; Ifran, Ahmet; Denkbaş, Emir Baki

    2010-10-01

    316L-type stainless steel is a raw material mostly used for manufacturing metallic coronary stents. The purpose of this study was to examine the chemical, wettability, cytotoxic and haemocompatibility properties of 316L stainless steel stents which were modified by plasma polymerization. Six different polymeric compounds, polyethylene glycol, 2-hydroxyethyl methacrylate, ethylenediamine, acrylic acid, hexamethyldisilane and hexamethyldisiloxane, were used in a radio frequency glow discharge plasma polymerization system. As a model antiproliferative drug, mitomycin-C was chosen for covalent coupling onto the stent surface. Modified SS 316L stents were characterized by water contact angle measurements (goniometer) and x-ray photoelectron spectroscopy. C1s binding energies showed a good correlation with the literature. Haemocompatibility tests of coated SS 316L stents showed significant latency (t-test, p 316L and control groups in each test.

  5. Infrared Brazing of Ti50Ni50 Shape Memory Alloy and 316L Stainless Steel with Two Sliver-Based Fillers

    Science.gov (United States)

    Shiue, Ren-Kae; Chen, Chia-Pin; Wu, Shyi-Kaan

    2015-06-01

    Dissimilar infrared brazing Ti50Ni50 and AISI 316L stainless steel using two silver-based fillers, Cusil-ABA and Ticusil, was evaluated. The shear strength of the Ticusil brazed joint is higher than that of the Cusil-ABA brazed one due to the formation of better fillet. The maximum shear strength of 237 MPa is obtained for the Ticusil joint brazed at 1223 K (950 °C) for 60 seconds. The presence of interfacial Ti-Fe-(Cu) layer is detrimental to the shear strength of all joints.

  6. Biocompatibility behavior of β–tricalcium phosphate-chitosan coatings obtained on 316L stainless steel

    Energy Technology Data Exchange (ETDEWEB)

    Mina, A. [Tribology, Powder Metallurgy and Processing of Solid Recycled Research Group, Universidad del Valle, Cali (Colombia); Caicedo, H.H. [Department of Anatomy and Cell Biology, University of Illinois at Chicago, IL, 60612 (United States); National Biotechnology & Pharmaceutical Association, Chicago, IL, 60606 (United States); Uquillas, J.A. [Universidad San Francisco de Quito USFQ, Colegio de Ciencias de la Salud COCSA, Escuela de Medicina, Hospital de los Valles, Edificio de Especialidades Médicas, Av. Interoceánica km 12 1/2 Cumbayá, Quito (Ecuador); Biomaterials Innovation Research Center, Department of Medicine, Brigham and Women' s Hospital, Harvard Medical School, Boston, MA, 02139 (United States); Aperador, W. [Departament of Engineering, Universidad Militar Nueva Granada, Bogotá (Colombia); Gutiérrez, O. [Departament of Pharmacology Universidad del Valle, Cali (Colombia); Caicedo, J.C., E-mail: julio.cesar.caicedo@correounivalle.edu.co [Tribology, Powder Metallurgy and Processing of Solid Recycled Research Group, Universidad del Valle, Cali (Colombia)

    2016-06-01

    Biological interfaces involve the interaction of complex macromolecular systems and other biomolecules or biomaterials. Researchers have used a combination of cell, material sciences and engineering approaches to create functional biointerfaces to help improve biological functions. Materials such as hydroxyapatite (HA), β-tricalcium phosphate (β-TCP) and chitosan are important biomaterials to be used in biomedical applications such as bone-prosthesis interfaces. In this work, it was evaluated the effect of different concentrations of chitosan on the structural, electrochemical and biocompatible properties of β-tricalcium phosphate-chitosan ((β-Ca{sub 3}(PO{sub 4}){sub 2})-(C{sub 6}H{sub 11}NO{sub 4})n) hybrid coatings. β–tricalcium phosphate-chitosan coatings were deposited on 316L stainless steel substrates applying 260 mA AC, an agitation velocity of 250 rpm, and temperature deposition of 60 °C. It was possible to obtain coatings of 600 μm of thickness. Structure and surface properties were analyzed by X-ray diffraction (XRD) and dispersive X-ray analysis (EDX). It was found that the arrangement of the β-TCP crystal lattice changed with increasing chitosan weight concentration, showing that the orthorhombic structure of β-TCP is under tensile stress. The electrochemical properties of β–tricalcium phosphate/chitosan (β-TCP–Ch) coatings were analyzed by electrochemical impedance spectroscopy (EIS). Cellular biocompatibility was determined by lactate dehydrogenase (LDH) cytotoxicity assay using primary chinese hamster ovary (CHO) cells. β-TCP–Ch coatings with chitosan concentrations up to 25% caused cytotoxic effects to only 5–10% of CHO cells. Obtained results showed the influence of chitosan in the structural, electrochemical, and biocompatible properties of AISI 316L Stainless Steel. Consequently, the electrochemical and cytotoxic behavior of β-TCP–Ch on 316L Stainless Steel indicated that the coatings might be a promising material in

  7. Cytotoxicity difference of 316L stainless steel and titanium reconstruction plate

    Directory of Open Access Journals (Sweden)

    Ni Putu Mira Sumarta

    2011-03-01

    Full Text Available Background: Pure titanium is the most biocompatible material today and used as a gold standard for metallic implants. However, stainless steel is still being used as implants because of its strength, ductility, lower price, corrosion resistant and biocompatibility. Purpose: This study was done to revealed the cytotoxicity difference between reconstruction plate made of 316L stainless steel and of commercially pure (CP titanium in baby hamster kidney-21 (BHK-21 fibroblast culture through MTT assay. Methods: Eight samples were prepared from reconstruction plates made of stainless steel type 316L grade 2 (Coen’s reconstruction plate® that had been cut into cylindrical form of 2 mm in diameter and 3 mm long. The other one were made of CP titanium (STEMA Gmbh® of 2 mm in diameter and 2,2 mm long; and had been cleaned with silica paper and ultrasonic cleaner, and sterilized in autoclave at 121° C for 20 minutes.9 Both samples were bathed into microplate well containing 50 μl of fibroblast cells with 2 x 105 density in Rosewell Park Memorial Institute-1640 (RPMI-1640 media, spinned at 30 rpm for 5 minutes. Microplate well was incubated for 24 and 48 hours in 37° C. After 24 hours, each well that will be read at 24 hour were added with 50 μl solution containing 5mg/ml MTT reagent in phosphate buffer saline (PBS solutions, then reincubated for 4 hours in CO2 10% and 37° C. Colorometric assay with MTT was used to evaluate viability of the cells population after 24 hours. Then, each well were added with 50 μl dimethyl sulfoxide (DMSO and reincubated for 5 minutes in 37° C. the wells were read using Elisa reader in 620 nm wave length. Same steps were done for the wells that will be read in 48 hours. Each data were tabulated and analyzed using independent T-test with significance of 5%. Results: This study showed that the percentage of living fibroblast after exposure to 316L stainless steel reconstruction plate was 61.58% after 24 hours and 62

  8. Effects of Admixed Titanium on Densification of 316L Stainless Steel Powder during Sintering

    Directory of Open Access Journals (Sweden)

    Aslam Muhammad

    2014-07-01

    Full Text Available Effects of admixed titanium on powder water atomized (PWA and powder gas atomized (PGA 316L stainless steel (SS have been investigated in terms of densification. PGA and PWA powders, having different shapes and sizes, were cold pressed and sintered in argon atmosphere at 1300°C. The admixed titanium compacts of PGA and PWA have shown significant effect on densification through formation of intermetallic compound and reducing porosity during sintering process. PWA, having particle size 8 μm, blended with 1wt% titanium has exhibited higher sintered density and shrinkage as compared to gas atomized powder compacts. Improved densification of titanium blended PGA and PWA 316L SS at sintering temperature 1300°C is probably due to enhanced diffusion kinetics resulting from stresses induced by concentration gradient in powder compacts.

  9. The structural and bio-corrosion barrier performance of Mg-substituted fluorapatite coating on 316L stainless steel human body implant

    Science.gov (United States)

    Sharifnabi, A.; Fathi, M. H.; Eftekhari Yekta, B.; Hossainalipour, M.

    2014-01-01

    In this study, Mg-substituted fluorapatite coatings were deposited on medical grade AISI 316L stainless steel via sol-gel dip coating method. Phase composition, crystallite size and degree of crystallinity of the obtained coatings were evaluated by X-ray diffraction (XRD) analysis. Fourier transform infrared (FTIR) spectroscopy was also used to evaluate functional groups of the obtained coatings. The surface morphology and cross-section of the final coatings were studied using scanning electron microscopy (SEM) and energy dispersive X-ray (EDX) spectroscopy was used to determine elemental chemical composition of the obtained coatings. In order to determine and compare the corrosion behavior of uncoated and Mg-substituted fluorapatite coated 316L stainless steel, electrochemical potentiodynamic polarization tests were performed in physiological solutions at 37 ± 1 °C. Moreover, the released metallic ions from uncoated and coated substrates were measured by inductively coupled plasma-optical emission spectrometry (ICP-OES) within 2 months of immersing in Ringer's solution at 36.5 ± 1 °C as an indication of biocompatibility. The results showed that fluoride and magnesium were successfully incorporated into apatite lattice structure and the prepared coatings were nanostructured with crystallinity of about 70%. Obtained coatings were totally crack-free and uniform and led to decrease in corrosion current densities of 316L stainless steel in physiological solutions. In addition, coated sample released much less ions such as Fe, Cr and Ni in physiological media. Therefore, it was concluded that Mg-substituted fluorapatite coatings could improve the corrosion resistance and biocompatibility of 316L stainless steel human body implants.

  10. The structural and bio-corrosion barrier performance of Mg-substituted fluorapatite coating on 316L stainless steel human body implant

    Energy Technology Data Exchange (ETDEWEB)

    Sharifnabi, A., E-mail: sharifnabi@yahoo.com [Biomaterials Group, Department of Metallurgy and Materials Engineering, Iran University of Science and Technology, Tehran, 16844 (Iran, Islamic Republic of); Fathi, M.H. [Biomaterials Research Group, Department of Materials Engineering, Isfahan University of Technology, Isfahan, 8415683111 (Iran, Islamic Republic of); Dental Materials Research Center, Isfahan University of Medical Sciences, Isfahan (Iran, Islamic Republic of); Eftekhari Yekta, B.; Hossainalipour, M. [Biomaterials Group, Department of Metallurgy and Materials Engineering, Iran University of Science and Technology, Tehran, 16844 (Iran, Islamic Republic of)

    2014-01-01

    In this study, Mg-substituted fluorapatite coatings were deposited on medical grade AISI 316L stainless steel via sol–gel dip coating method. Phase composition, crystallite size and degree of crystallinity of the obtained coatings were evaluated by X-ray diffraction (XRD) analysis. Fourier transform infrared (FTIR) spectroscopy was also used to evaluate functional groups of the obtained coatings. The surface morphology and cross-section of the final coatings were studied using scanning electron microscopy (SEM) and energy dispersive X-ray (EDX) spectroscopy was used to determine elemental chemical composition of the obtained coatings. In order to determine and compare the corrosion behavior of uncoated and Mg-substituted fluorapatite coated 316L stainless steel, electrochemical potentiodynamic polarization tests were performed in physiological solutions at 37 ± 1 °C. Moreover, the released metallic ions from uncoated and coated substrates were measured by inductively coupled plasma-optical emission spectrometry (ICP-OES) within 2 months of immersing in Ringer's solution at 36.5 ± 1 °C as an indication of biocompatibility. The results showed that fluoride and magnesium were successfully incorporated into apatite lattice structure and the prepared coatings were nanostructured with crystallinity of about 70%. Obtained coatings were totally crack-free and uniform and led to decrease in corrosion current densities of 316L stainless steel in physiological solutions. In addition, coated sample released much less ions such as Fe, Cr and Ni in physiological media. Therefore, it was concluded that Mg-substituted fluorapatite coatings could improve the corrosion resistance and biocompatibility of 316L stainless steel human body implants.

  11. Improving the Adhesion Resistance of the Boride Coatings to AISI 316L Steel Substrate by Diffusion Annealing

    Science.gov (United States)

    Campos-Silva, I.; Bernabé-Molina, S.; Bravo-Bárcenas, D.; Martínez-Trinidad, J.; Rodríguez-Castro, G.; Meneses-Amador, A.

    2016-09-01

    In this study, new results about the practical adhesion resistance of boride coating/substrate system formed at the surface of AISI 316 L steel and improved by means of a diffusion annealing process are presented. First, the boriding of AISI 316 L steel was performed by the powder-pack method at 1173 K with different exposure times (4-8 h). The diffusion annealing process was conducted on the borided steels at 1273 K with 2 h of exposure using a diluent atmosphere of boron powder mixture. The mechanical behavior of the boride coating/substrate system developed by both treatments was established using Vickers and Berkovich tests along the depth of the boride coatings, respectively. Finally, for the entire set of experimental conditions, the scratch tests were performed with a continuously increasing normal force, in which the practical adhesion resistance of the boride coating/substrate system was represented by the critical load. The failure mechanisms developed over the surface of the scratch tracks were analyzed; the FeB-Fe2B/substrate system exhibited an adhesive mode, while the Fe2B/substrate system obtained by the diffusion annealing process showed predominantly a cohesive failure mode.

  12. Decapado del acero inoxidable AISI 316L utilizando una mezcla ecológica de H2O2-H2SO4-HF

    Directory of Open Access Journals (Sweden)

    Gómez, P. P.

    2005-12-01

    Full Text Available This study reports the pickling of austenitic AISI 316L stainless steel (SS using a mixture of hydrogen peroxide (H2O2, sulphuric acid (H2SO4 and hydrofluoric acid (HF at pH 2.0. The stability of H2O2 was also studied using different concentrations of ferric ion from 0 to 40 g/l and temperature from 25 to 60 °C. The pickling rate at 50 °C in the presence and absence of 40 g/l ferric ion was 2.6 and 0.2 mg/dm2 day (mdd, respectively. p-Toluene sulphonic acid was used as stabilizer of H2O2.En la presente investigación se estudia el decapado del acero inoxidable AISI 316L utilizando una mezcla de agua oxigenada (H2O2 y los ácidos sulfúrico (H2SO4 y fluorhídrico (HF a pH 2,0. La estabilidad de la mezcla H2O2-H2SO4-HF se ha ensayado variando el contenido de iones férrico de O a 40 g/l y la temperatura de 25 a 60 °C. La velocidad de decapado a 50 °C ha sido de 2,6 y 0,2 mg/dm2 día (mdd, en ausencia y presencia de 40 g/l de iones férrico, respectivamente. Se ha utilizado el ácido p-toluen sulfónico como estabilizante del H2O2.

  13. Microscopic work function anisotropy and surface chemistry of 316L stainless steel using photoelectron emission microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Barrett, N., E-mail: nick.barrett@cea.fr [CEA, IRAMIS, SPEC, LENSIS, F-91191 Gif-sur-Yvette (France); Renault, O. [CEA, LETI, Minatec Campus, F-38054 Grenoble Cedex 09 (France); Lemaître, H. [Université de Cergy-Pontoise, Rue d’Eragny, Neuville sur Oise, 95 031 Cergy-Pontoise (France); Surface Dynamics Laboratory, Institut for Fysik og Astronomi Aarhus Universitet, Ny Munkegade 120, 8000 Aarhus C (Denmark); Bonnaillie, P. [CEA, DEN, DANS, DMN, SRMP, F-91191 Gif-sur-Yvette (France); Barcelo, F. [CEA, DEN, DANS, DMN, SRMA, LA2M, F-91191 Gif-sur-Yvette (France); Miserque, F. [CEA, DEN, DANS, DPC, SCCME, LECA, F-91191 Gif-sur-Yvette (France); Wang, M.; Corbel, C. [Laboratoire des Solides Irradis, Ecole Polytechnique, route de Saclay, F-91128 Palaiseau (France)

    2014-08-15

    Highlights: • PEEM and EBSD study of spatial variations in local work function of 316L steel. • Correlation between work function and crystal grain orientation at the surface of 316L steel. • Spatially resolved chemistry of residual oxide layer. - Abstract: We have studied the variation in the work function of the surface of sputtered cleaned 316L stainless steel with only a very thin residual oxide surface layer as a function of grain orientation using X-ray photoelectron emission microscopy (XPEEM) and Electron Backscattering Diffraction. The grains are mainly oriented [1 1 1] and [1 0 1]. Four distinct work function values spanning a 150 meV energy window are measured. Grains oriented [1 1 1] have a higher work function than those oriented [1 0 1]. From core level XPEEM we deduce that all grain surfaces are Cr enriched and Ni depleted whereas the Cr/Fe ratio is similar for all grains. The [1 1 1] oriented grains show evidence for a Cr{sub 2}O{sub 3} surface oxide and a higher concentration of defective oxygen sites.

  14. Parylene coatings on stainless steel 316L surface for medical applications--mechanical and protective properties.

    Science.gov (United States)

    Cieślik, Monika; Kot, Marcin; Reczyński, Witold; Engvall, Klas; Rakowski, Wiesław; Kotarba, Andrzej

    2012-01-01

    The mechanical and protective properties of parylene N and C coatings (2-20 μm) on stainless steel 316L implant materials were investigated. The coatings were characterized by scanning electron and confocal microscopes, microindentation and scratch tests, whereas their protective properties were evaluated in terms of quenching metal ion release from stainless steel to simulated body fluid (Hanks solution). The obtained results revealed that for parylene C coatings, the critical load for initial cracks is 3-5 times higher and the total metal ions release is reduced 3 times more efficiently compared to parylene N. It was thus concluded that parylene C exhibits superior mechanical and protective properties for application as a micrometer coating material for stainless steel implants.

  15. Influence of enzymatic reactions on the electrochemical behavior of EN X2CrNiMo17-11-2 (AISI 316L) stainless steel in bio-corrosion: role of interfacial processes on the modification of the passive layer; Influence des reactions enzymatiques sur le comportement electrochimique de l'acier inoxydable ENX2CrNiMo17-11-2 (AISI 316L) en biocorrosion: role des processus interfaciaux sur la modification du film passif

    Energy Technology Data Exchange (ETDEWEB)

    Landoulsi, J

    2008-01-15

    The outstanding corrosion behavior of stainless steels (SS) results from the presence of thin oxide layer (some nanometers). In non sterile aqueous media, stainless steels may exhibit a non stable behavior resulting from interactions between microbial species and passive film. In fact, microorganisms can be deeply involved in the corrosion processes usually reported as Microbial Influenced Corrosion (MIC). They can induce the initiation or the acceleration of this phenomenon and they do so when organized in bio-films. From the electrochemical point of view, stainless steels showed an increase of the free corrosion potential (Ecorr) attributed to the bio-film settlement. The Eco' ennoblement was broadly reported in seawater and seems to be confirmed in fresh water according to recent findings. A considerable progress in the comprehension of MIC processes was related to the role of extracellular species, essentially enzymes. Many enzymatic reactions occurring in bio-films consist on using oxygen as electron acceptor to generate hydrogen peroxide and related species. The aim of this work is to understand the mechanisms involved in the electrochemical behavior of stainless steel according to an enzymatic approach in medium simulating fresh water. To this end, glucose oxidase was chosen to globalize aerobic activities of bio-films. Electrochemical measurements in situ and surface analysis allow the comprehension of the role and the nature of interfacial processes. Surface characterization was performed with the help of a new quantitative utilization of XPS analysis and AFM. Results show a significant evolution in term of morphology (surface organization), (ii) chemical composition (passive layer, adsorbed organic species) and (iii) chemical reaction (oxidation, dissolution, effect of enzyme). Finally, a new enzymatic system is proposed to mimic specific physicochemical conditions at the SS / bio-film interface, in particular enzymatic generation of oxidant species

  16. Preparation and characterization of stainless steel 316L/HA biocomposite

    Directory of Open Access Journals (Sweden)

    Gilbert Silva

    2013-04-01

    Full Text Available The austenitic stainless steel 316L is the most used metallic biomaterials in orthopedics applications, especially in the manufacture of articulated prostheses and as structural elements in fracture fixation, since it has high mechanical strength. However, because it is biologically inactive, it does not form chemical bond with bone tissue, it is fixed only by morphology. The development of biocomposites of stainless steel with a bioactive material, such as hydroxyapatite - HA, is presented as an alternative to improve the response in the tissue-implant interface. However significant reductions in mechanical properties of the biocomposite can occur. Different compositions of the biocomposite stainless steel 316L/HA (5, 20 and 50 wt. (% HA were prepared by mechanical alloying. After milling the powders for 10 hours, the different compositions of the biocomposite were compacted isostatically and sintered at 1200 ºC for 2 hours. The mechanical properties of the biocomposites were analyzed by compression tests. The powders and the sintered composites were analyzed by scanning electron microscopy (SEM and X-ray diffraction (XRD.

  17. Systematic Study of Nanocrystalline Plasma Electrolytic Nitrocarburising of 316L Austenitic Stainless Steel for Corrosion Protection

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    A number of studies have been reported on the use of nanocrystalline plasma electrolytic nitrocarburising technology for surface hardening of stainless steels for higher corrosion resistance resulted from this technique. However, very few studies have focused on the optimization of the nanocrystalline plasma electrolytic nitrocarburising process parameters. In this study, a design of experiment (DOE) technique, the Taguchi method, has been used to optimize the nanocrystalline plasma electrolytic nitrocarburising not only for surface hardening but also for the corrosion protection of 316L austenitic stainless steel by controlling the coating process's factors. The experimental design consisted of four factors (Urea concentration, electrical conductivity of electrolyte, voltage and duration of process), each containing three levels. Potentiodynamic polarization measurements were carried out to determine the corrosion resistance of the coated samples. The results were analyzed with related software. An analysis of the mean of signal-to-noise (S/N) ratio indicated that the corrosion resistance of nanocrystalline plasma electrolytic nitrocarburised 316L stainless steel was influenced significantly by the levels in the Taguchi orthogonal array. The optimized coating parameters for corrosion resistance are 1150 g/L for urea concentration, 360 mS/cm for electrical conductivity of electrolyte, 260 V for applied voltage, 6 min for treatment time. The percentage of contribution for each factor was determined by the analysis of variance (ANOVA). The results showed that the applied voltage is the most significant factor affecting the corrosion resistance of the coatings.

  18. Hydrothermal calcium modification of 316L stainless steel and its apatite forming ability in simulated body fluid.

    Science.gov (United States)

    Valanezahad, Alireza; Ishikawa, Kunio; Tsuru, Kanji; Maruta, Michito; Matsuya, Shigeki

    2011-01-01

    To understand the feasibility of calcium (Ca) modification of type 316L stainless steel (316L SS) surface using hydrothermal treatment, 316L SS plates were treated hydrothermally in calcium chloride (CaCl(2)) solution. X-ray photoelectron spectroscopic analysis revealed that the surface of 316L SS plate was modified with Ca after hydrothermal treatment at 200°C. And the immobilized Ca increased with CaCl(2) concentration. However no Ca-modification was occurred for 316L SS plates treated at 100°C. When Ca-modified 316L SS plate was immersed in simulated body fluid (SBF) with ion concentrations nearly equal to those of human blood plasma, low crystalline apatite was precipitated on its surface whereas no precipitate was observed on non Ca-modified 316L SS. The results obtained in the present study indicated that hydrothermal treatment at 200°C in CaCl(2) solution is useful for Ca-modification of 316L SS, and Ca-modification plays important role for apatite precipitation in SBF.

  19. [Measurement of low corrosion rate of coronary stents-made of 316L and 317L stainless steel].

    Science.gov (United States)

    Liang, Chenghao; Guo, Liang; Chen, Wan

    2006-08-01

    Electrochemical constant current linear polarization and atomic absorption spectroscopy were used to measure the corrosion rate of coronary stents made of 316L and 317L stainless steel in 30 degrees C Tyrode's solution. The results indicated that the corrosion rate of 316L and 317L stainless steel was 21 X 10(-3) microm/a, 9.8 X 10(-3) microm/a and 0.8 X 10(-3) m/a, 0.6 X 10(-3) microm/a, respectively. All corrosion rates were lower than the medical materials corrosion rate criteria, i.e. 0.25 microm/a. Moreover the corrosion resistance of 317L stainless steel was much higher than that of 316L stainless steel. The results from atomic absorption spectroscopy may correctly reflect the quantity of releasing metal ions in the solution.

  20. Drug delivery from therapeutic self-assembled monolayers (T-SAMs) on 316L stainless steel.

    Science.gov (United States)

    Mahapatro, Anil; Johnson, Dave M; Patel, Devang N; Feldman, Marc D; Ayon, Arturo A; Agrawal, C Mauli

    2008-01-01

    Delivery of therapeutic agents from self-assembled monolayers (SAMs) on 316L stainless steel (SS) has been demonstrated as a viable method to deliver drugs for localized coronary artery stent application. SAMs are highly-ordered, nano-sized molecular coatings, adding 1-10 nm thickness to a surface. Hydroxyl terminated alkanethiol SAMs of 11-mercapto-1-undecanol (-OH SAM) were formed on 316L SS with 48 hr immersion in ethanolic solutions. Attachment of ibuprofen (a model drug) to the functional SAMs was carried out in toluene for 5 hrs at 60 degrees C using Novozume-435 as a biocatalyst. SAM formation and subsequent attachment of ibuprofen was characterized collectively using X-ray photoelectron spectroscopy (XPS), Fourier transform infrared spectroscopy (FTIR), and contact angle (CA) measure-ments. The quantitative in vitro release of ibuprofen into a "physiological" buffer solution was characterized using reverse phase HPLC. Drug release kinetics showed that 14.1 microg of ibuprofen eluted over a period of 35 days with 2.7microg being eluted in the first day and the remaining being eluted over a period of 35 days. The drug release kinetics showed an increase in ibuprofen elution that occurred during first 14 days (2.7microg in 1 day to 9.5 microg in 14 days), following which there was a decrease in the rate of elution. Thus, functional SAMs on 316L SS could be used as tethers for drug attachment and could serve as a drug delivery mechanism from stainless steel implants such as coronary artery stents.

  1. Effect of boron addition on injection molded 316L stainless steel: mechanical, corrosion properties and in vitro bioactivity.

    Science.gov (United States)

    Bayraktaroglu, Esra; Gulsoy, H Ozkan; Gulsoy, Nagihan; Er, Ozay; Kilic, Hasan

    2012-01-01

    The research was investigated the effect of boron additions on sintering characteristics, mechanical, corrosion properties and biocompatibility of injection molded austenitic grade 316L stainless steel. Addition of boron is promoted to get high density of sintered 316L stainless steels. The amount of boron plays a role in determining the sintered microstructure and all properties. In this study, 316L stainless steel powders have been used with the elemental NiB powders. A feedstock containing 62.5 wt% powders loading was molded at different injection molded temperature. The binders were completely removed from molded components by solvent and thermal debinding at different temperature. The debinded samples were sintered at different temperature for 60 min. Mechanical property, microstructural characterization and electrochemical property of the sintered samples were performed using tensile testing, hardness, optical, scanning electron microscopy and electrochemical corrosion experiments. Sintered samples were immersed in a simulated body fluid (SBF) with elemental concentrations that were comparable to those of human blood plasma for a total period of 15 days. Both materials were implanted in fibroblast culture for biocompatibility evaluations were carried out. Results of study showed that sintered 316L and 316L with NiB addition samples exhibited high mechanical and corrosion properties in a physiological environment. Especially, 316L with NiB addition can be used in some bioapplications.

  2. Passivation Mechanism of 316L Stainless Steel in Oxidizing Acid Solution

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    The compositions and the chemical valence states of elements of 316L stainless steel passive film formed in the oxidizing acid solution were studied by X-ray Photoelectron Spectroscopic (XPS) analysis. The electrochemical polarization curve was measured. The passivation process in the oxidizing acid solution was studied by AC impedance technology. The results indicated that the stable compounds layer was formed on the surface of the sample and the adsorption was the main step in the nitrite solution during passivation process. The catalysis passivation mechanism was put forward according to the experimental results. During passivation process, the water molecule was adsorbed on the surface of the sample at first in the oxidizing acid solution. The oxidizer in the solution played a role as catalyst. The oxide and hydroxide, which could be changed each other and finally formed stable passive film, were generated from adsorbing intermediate under the catalytic action. The mathematical models for predicting the steady polarization curve and the AC impedance spectra at certain conditions have been obtained. The passivation mechanism of 316L stainless steel in the oxidizing acid solution can be interpreted by the catalysis passivation mechanism.

  3. Strain rate dependence of impact properties of sintered 316L stainless steel

    Science.gov (United States)

    Lee, Woei-Shyan; Lin, Chi-Feng; Liu, Tsung-Ju

    2006-12-01

    This paper uses a material testing system (MTS) and a compressive split-Hopkinson bar to investigate the impact behaviour of sintered 316L stainless steel at strain rates ranging from 10 -3 s -1 to 7.5 × 10 3 s -1. It is found that the true stress, the rate of work hardening and the strain rate sensitivity vary significantly as the strain rate increases. The flow behaviour of the sintered 316L stainless steel can be accurately predicted using a constitutive law based on Gurson's yield criterion and the flow rule proposed by Khan, Huang and Liang (KHL). Microstructural observations reveal that the degree of localized grain deformation increases, but the pore density and the grain size decrease, with increasing strain rate. Adiabatic shear bands associated with cracking are developed at strain rates higher than 5.6 × 10 3 s -1. The fracture surfaces exhibit ductile dimples. The depth and density of these dimples decrease with increasing strain rate.

  4. Strain rate dependence of impact properties of sintered 316L stainless steel

    Energy Technology Data Exchange (ETDEWEB)

    Lee, W.-S. [Department of Mechanical Engineering, National Cheng Kung University, Tainan 701, Taiwan (China)]. E-mail: wslee@mail.ncku.edu.tw; Lin, C.-F. [National Center for High-Performance Computing, Hsin-Shi Tainan County 744, Taiwan (China); Liu, T.-J. [Department of Mechanical Engineering, National Cheng Kung University, Tainan 701, Taiwan (China)

    2006-12-15

    This paper uses a material testing system (MTS) and a compressive split-Hopkinson bar to investigate the impact behaviour of sintered 316L stainless steel at strain rates ranging from 10{sup -3} s{sup -1} to 7.5 x 10{sup 3} s{sup -1}. It is found that the true stress, the rate of work hardening and the strain rate sensitivity vary significantly as the strain rate increases. The flow behaviour of the sintered 316L stainless steel can be accurately predicted using a constitutive law based on Gurson's yield criterion and the flow rule proposed by Khan, Huang and Liang (KHL). Microstructural observations reveal that the degree of localized grain deformation increases, but the pore density and the grain size decrease, with increasing strain rate. Adiabatic shear bands associated with cracking are developed at strain rates higher than 5.6 x 10{sup 3} s{sup -1}. The fracture surfaces exhibit ductile dimples. The depth and density of these dimples decrease with increasing strain rate.

  5. Cytocompatibility and mechanical properties of novel porous 316 L stainless steel

    Energy Technology Data Exchange (ETDEWEB)

    Kato, Komei, E-mail: kkato@mmc.co.jp [Mitsubishi Material Corp. 1-297 Kitabukuro-cho, Omiya-ku, Saitama, 330-8508 (Japan); Yamamoto, Akiko [Biomaterials Center, National Institute for Materials Science (NIMS), 1-1 Namiki, Tsukuba, Ibaraki 305-0044 (Japan); International Center for Materials Nanoarchitectonics (WPI-MANA), National Institute for Materials Science (NIMS), 1-1 Namiki, Tsukuba, Ibaraki 305-0044 (Japan); Ochiai, Shojiro [Department of Materials Science and Engineering, Graduate School of Engineering, Kyoto University, Yoshida, Sakyo-ku, Kyoto 606-8501 (Japan); Wada, Masahiro; Daigo, Yuzo [Mitsubishi Materials Corp. Advanced and Tools Company, High Performance Alloy Products Div. 476 Shimoishido-shimo, Kitamoto, Saitama 364-0023 (Japan); Kita, Koichi [Mitsubishi Materials C.M.I. Corp. Alloy Products Div. 46-1 Sempuku Susono Shizuoka-ken 410-1116 (Japan); Omori, Kenichi [Biomaterials Center, National Institute for Materials Science (NIMS), 1-1 Namiki, Tsukuba, Ibaraki 305-0044 (Japan)

    2013-07-01

    Novel 316 L stainless steel (SS) foam with 85% porosity and an open pore diameter of 70–440 μm was developed for hard tissue application. The foam sheet with a 200-μm diameter had superior cell proliferation and penetration as identified through in vitro experiments. Calcification of human osteosarcoma cells in the SS foam was observed. Multi-layered foam preparation is a potential alternative technique that satisfies multi-functional requirements such as cell penetration and binding strength to the solid metal. In tensile tests, Young's modulus and the strength of the SS foam were 4.0 GPa and 11.2 MPa respectively, which is comparable with human cancellous bone. - Highlights: • Novel 316 L stainless steel foam with 85% porosity and a pore diameter of 70–440 μm was developed. • The optimum pore diameter of the foam was 200 μm for cell proliferation and penetration. • Cell penetration in the multi-layered foam was controlled by the pore structures of the top layer. • Calcification of human osteosarcoma was confirmed in the foam and increased with incubation time. • Young's modulus and the tensile strength of the foam were comparable with human cancellous bone.

  6. Corrosion of type 316L stainless steel in a mercury thermal convection loop

    Energy Technology Data Exchange (ETDEWEB)

    DiStefano, J.R.; Manneschmidt, E.T.; Pawel, S.J.

    1999-04-01

    Two thermal convection loops fabricated from 316L stainless steel containing mercury (Hg) and Hg with 1000 wppm gallium (Ga), respectively, were operated continuously for about 5000 h. In each case, the maximum loop temperature was constant at about 305 degrees C and the minimum temperature was constant at about 242 degrees C. Coupons in the hot leg of the Hg-loop developed a posous surface layer substantially depleted of nickel and chromium, which resulted in a transformation to ferrite. The coupon exposed at the top of the hot leg in the Hg-loop experienced the maximum degradation, exhibiting a surface layer extending an average of 9-10 mu m after almost 5000 h. Analysis of the corrosion rate data as a function of temperature (position) in the Hg-loop suggests wetting by the mer cury occurred only above about 255 degrees C and that the rate limiting step in the corrosion process above 255 degrees C is solute diffusion through the saturated liquid boundary layer adjacent to the corroding surface. The latter factor suggests that the corrosion of 316L stainless steel in a mercury loop may be velocity dependent. No wetting and no corrosion were observed on the coupons and wall specimens removed from the Hg/Ga loop after 5000 h of operation.

  7. Partially degradable friction-welded pure iron-stainless steel 316L bone pin.

    Science.gov (United States)

    Nasution, A K; Murni, N S; Sing, N B; Idris, M H; Hermawan, H

    2015-01-01

    This article describes the development of a partially degradable metal bone pin, proposed to minimize the occurrence of bone refracture by avoiding the creation of holes in the bone after pin removal procedure. The pin was made by friction welding and composed of two parts: the degradable part that remains in the bone and the nondegradable part that will be removed as usual. Rods of stainless steel 316L (nondegradable) and pure iron (degradable) were friction welded at the optimum parameters: forging pressure = 33.2 kPa, friction time = 25 s, burn-off length = 15 mm, and heat input = 4.58 J/s. The optimum tensile strength and elongation was registered at 666 MPa and 13%, respectively. A spiral defect formation was identified as the cause for the ductile fracture of the weld joint. A 40-µm wide intermetallic zone was identified along the fusion line having a distinct composition of Cr, Ni, and Mo. The corrosion rate of the pin gradually decreased from the undeformed zone of pure iron to the undeformed zone of stainless steel 316L. All metallurgical zones of the pin showed no toxic effect toward normal human osteoblast cells, confirming the ppb level of released Cr and Ni detected in the cell media were tolerable.

  8. Stability of passivated 316L stainless steel oxide films for cardiovascular stents.

    Science.gov (United States)

    Shih, Chun-Che; Shih, Chun-Ming; Chou, Kuang-Yi; Lin, Shing-Jong; Su, Yea-Yang

    2007-03-15

    Passivated 316L stainless steel is used extensively in cardiovascular stents. The degree of chloride ion attack might increase as the oxide film on the implant degrades from exposure to physiological fluid. Stability of 316L stainless steel stent is a function of the concentration of hydrated and hydrolyated oxide concentration inside the passivated film. A high concentration of hydrated and hydrolyated oxide inside the passivated oxide film is required to maintain the integrity of the passivated oxide film, reduce the chance of chloride ion attack, and prevent any possible leaching of positively charged ions into the surrounding tissue that accelerate the inflammatory process. Leaching of metallic ions from corroded implant surface into surrounding tissue was confirmed by the X-ray mapping technique. The degree of thrombi weight percentage [W(ao): (2.1 +/- 0.9)%; W(ep): (12.5 +/- 4.9)%, p < 0.01] between the amorphous oxide (AO) and the electropolishing (EP) treatment groups was statistically significant in ex-vivo extracorporeal thrombosis experiment of mongrel dog. The thickness of neointima (T(ao): 100 +/- 20 microm; T(ep): 500 +/- 150 microm, p < 0.01) and the area ratio of intimal response at 4 weeks (AR(ao): 0.62 +/- 0.22; AR(ep): 1.15 +/- 0.42, p < 0.001) on the implanted iliac stents of New Zealand rabbit could be a function of the oxide properties.

  9. Preparation and surface characterization of HMDI-activated 316L stainless steel for coronary artery stents.

    Science.gov (United States)

    Chuang, T-W; Chen, M-H; Lin, F-H

    2008-06-01

    Poor compatibility between blood and metallic coronary artery stents is one reason for arterial restenosis. Immobilization of anticoagulant agents on the stent's surface is feasible for improving compatibility. We examined possible surface-coupling agents for anticoagulant agent immobilization. Hexamethylene diisocyanate (HMDI) and 3-aminopropyl-triethoxysilane (APTS) were examined as surface-coupling agents to activate 316L stainless steel (e.g., stent material). The activated surface was characterized using Fourier transformation infrared spectroscopy (FTIR), atomic force microscope (AFM), surface plasmon resonance (SPR), and trinitrobenzene sulfonic acid (TNBS) assay. In FTIR analysis, HMDI and APTS were both covalently linked to 316L stainless steel. In AFM analysis, it was found that the HMDI-activated surface was smoother than the APTS-activated one. In SPR test, the shift of SPR angle for the APTS-activated surface was much higher than that for the HMDI-activated surface after being challenged with acidic solution. TNBS assay was used to determine the amount of immobilized primary amine groups. The HMDI-activated surface was found to consist of about 1.32 micromol/cm(2) amine group, whereas the APTS-activated surface consisted of only 0.89 micromol/cm(2) amine group. We conclude that the HMDI-activated surface has more desirable surface characteristics than the APTS-activated surface has, such as chemical stability and the amount of active amine groups.

  10. The surface cleanliness of 316 L + N stainless steel studied by SIMS and AES

    CERN Document Server

    Mathewson, A G

    1974-01-01

    Some cleaning methods for 316 L+N stainless steel including solvent cleaning, high temperature treatment in vacuo and gas discharge cleaning have been studied by SIMS and AES with a view to providing a clean vacuum chamber surface with low gas desorption under ion bombardment. After solvent cleaning the main surface contaminant was found to be C and its associated compounds. Laboratory investigations on small samples of stainless steel showed that clean surfaces could be obtained by heating in vacuo to 800 degrees C followed by exposure to air and by argon or argon/10% oxygen discharge cleaning. Due to a cross contamination within the vacuum system, the 800 degrees C treated chamber gave positive desorption coefficients under ion bombardment. The pure argon discharge cleaned chambers proved stable giving negative desorption coefficients up to 2200 eV ion energy even after several weeks storage discharge treatment and installation. (10 refs).

  11. Acoustic emission detection of 316L stainless steel welded joints during intergranular corrosion

    Institute of Scientific and Technical Information of China (English)

    Meng-yu Chai; Quan Duan; Wen-jie Bai; Zao-xiao Zhang; Xu-meng Xie

    2015-01-01

    This study analyzes acoustic emission (AE) signals during the intergranular corrosion (IGC) process of 316L stainless steel welded joints under different welding currents in boiling nitric acid. IGC generates several AE signals with high AE activity. The AE tech-nique could hardly distinguish IGC in stainless steel welded joints with different welding heat inputs. However, AE signals can effectively distinguish IGC characteristics in different corrosion stages. The IGC resistance of a heat-affected zone is lower than that of a weld zone. The initiation and rapid corrosion stages can be distinguished using AE results and microstructural analysis. Moreover, energy count rate and am-plitude are considered to be ideal parameters for characterizing different IGC processes. Two types of signals are detected in the rapid corro-sion stage. It can be concluded that grain boundary corrosion and grain separation are the AE sources of type 1 and type 2, respectively.

  12. Study of TiC+TiN Multiple Films On Type of 316L Stainless Steel

    Institute of Scientific and Technical Information of China (English)

    XUE Qi; JIN Yong; HU Dong-ping; HUANG Ben-sheng; DENG Bai-quan

    2004-01-01

    In this paper, the synthesis process of TiC+TiN multiple films on super-low-carbon stainless steels is reported.The TiC layer is coated as the first layer in the multiple film, the change of growth rate of the film on the 316L Stainless steel is not same as the one on carbides substrates, while the mole ratio of CH4 to TiCl4 (mCH4/TiCl4) is changed from 1.2to 2.0. The Ti [C, N], as a kind of inter-layer between TiC and TiN layers, is helpful to improve the adhesion between the TiC and TiN layer. The cooling rate greatly influences the quality of the adhesion between the TiC+TiN film and substrates.

  13. Electrochemical and In Vitro Behavior of Nanostructure Sol-Gel Coated 316L Stainless Steel Incorporated with Rosemary Extract

    Science.gov (United States)

    Motalebi, Abolfazl; Nasr-Esfahani, Mojtaba

    2013-06-01

    The corrosion resistance of AISI 316L stainless steel for biomedical applications, was significantly enhanced by means of hybrid organic-inorganic sol-gel thin films deposited by spin-coating. Thin films of less than 100 nm with different hybrid characters were obtained by incorporating rosemary extract as green corrosion inhibitor. The morphology, composition, and adhesion of hybrid sol-gel coatings have been examined by SEM, EDX, and pull-off test, respectively. Addition of high additive concentrations (0.1%) did not disorganize the sol-gel network. Direct pull-off test recorded a mean coating-substrate bonding strength larger than 21.2 MPa for the hybrid sol-gel coating. The effect of rosemary extract, with various added concentrations from 0.012 to 0.1%, on the anticorrosion properties of sol-gel films have been characterized by electrochemical impedance spectroscopy (EIS) and potentiodynamic polarization tests in simulated body fluid (SBF) solution and has been compared to the bare metal. Rosemary extract additions (0.05%) have significantly increased the corrosion protection of the sol-gel thin film to higher than 90%. The in vitro bioactivity of prepared films indicates that hydroxyapatite nuclei can form and grow on the surface of the doped sol-gel thin films. The present study shows that due to their excellent anticorrosion properties, bioactivity and bonding strength to substrate, doped sol-gel thin films are practical hybrid films in biomedical applications.

  14. Experimental investigations on effects of frequency in ultrasonically-assisted end-milling of AISI 316L: A feasibility study.

    Science.gov (United States)

    Maurotto, A; Wickramarachchi, C T

    2016-02-01

    The effects of frequency in ultrasonic vibration assisted milling (UVAM) with axial vibration of the cutter is investigated in this paper. A series of face-mill experiment in dry conditions were conducted on AISI 316L, an alloy of widespread use in industry. The finished surfaces roughness were studied along with basic considerations on tool wear for both conventional milling and an array of frequencies for UVAM (20–40–60 kHz) in a wide range of cutting conditions. Surface residual stresses and cross-cut metallographic slides were used to investigate the hidden effects of UVAM. Experimental results showed competitive results for both surface roughness and residual stress in UVAM when compared with conventional milling especially in the low range of frequency with similar trend for tool wear.

  15. Effect of Cold-Rolling on Precipitation Phenomena in Sensitized Type 316L and 340L Austenitic Stainless Steels

    Institute of Scientific and Technical Information of China (English)

    H.Tsubakino; A.Yamamoto; T. Yamada; L.Liu; M.Terasawa; S.Nakahigashi; H.Harada

    2004-01-01

    Precipitation phenomena in Type 316L and 304L stainless steels were studied mainly by transmission electron microscopic (TEM) observations after cold-rolling ranging from 0% (as solution annealed) to 80% reduction in thickness,and then by sensitization treatment. Precipitates were identified by electron diffraction analysis and EDS analysis.Precipitates observed in sensitized 316L stainless steel were sigma and chi phases, whereas carbide and sigma were observed in sensitized 304L stainless steel. Recrystallized grains were formed in 30% cold-rolled and sensitized 304L.However, the tendency toward recrystallization in sensitized 316L was much lower than in 304L. Precipitation of sigma and chi phases was accelerated by cold-rolling and they were observed at grain boundaries in lower cold-rolling; they were also seen, in grain interiors in higher cold-rolling. Higher deformation induced partially recrystallization combined with precipitation, resulting in the formation of heterogeneous microstructures.

  16. Electrophoretic deposition of a bioactive Si, Ca-rich glass coating on 316L stainless steel for biomedical applications

    Directory of Open Access Journals (Sweden)

    H. H. Rodríguez

    2011-12-01

    Full Text Available This work consisted in the development and characterization of a vitroceramic coating on 316L stainless steel bymeans of electrophoretic deposition (EPD. This vitroceramic coating was obtained through a Si-, Ca-rich glas coating crystallization. The electrophoretic deposition tests were performed on 316L stainless steel mechanically polished substrates. The results suggest that the electrophoretic coatings adhered well to the metallic surfaces. Theresults demonstrate that the crystallized coatings are potentially bioactive, because a dense and homogeneous apatite layer, similar to a bone, makes up.

  17. Electrodeposition of polypyrrole on 316L stainless steel for corrosion prevention

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, M.B. [Instituto de Ingenieria Electroquimica y Corrosion (INIEC), Departamento de Ingenieria Quimica, Universidad Nacional del Sur, Av. Alem 1253, 8000 Bahia Blanca (Argentina); Saidman, S.B., E-mail: ssaidman@criba.edu.a [Instituto de Ingenieria Electroquimica y Corrosion (INIEC), Departamento de Ingenieria Quimica, Universidad Nacional del Sur, Av. Alem 1253, 8000 Bahia Blanca (Argentina)

    2011-01-15

    Research highlights: {yields} PPy films were electrodeposited on 316L SS in solutions containing MoO{sub 4}{sup 2-} and/or NO{sub 3}{sup -}. {yields} The coatings completely inhibit pitting corrosion in chloride solutions. {yields} At pH 12, the PPy is electroactive and the oxide film is more stable. {yields} The more protective films were obtained in presence of MoO{sub 4}{sup 2-} and NO{sub 3}{sup -} at pH 12. - Abstract: The electrosynthesis of polypyrrole films onto 316L stainless steel from near neutral and alkaline solutions containing molybdate and nitrate is reported. The corrosion behavior of the coated electrodes was investigated in NaCl solutions by electrochemical techniques and scanning electron microscopy. The polymer formed potentiostatically in a solution of pH 12 is the most efficient in terms of adhesion and corrosion protection. The coating significantly reduces the pitting corrosion of the substrate. The results are interpreted in terms of the nature of dopants, the good electroactivity of the polymer formed in alkaline solution and the passivating properties of the oxide layer.

  18. Estudo comparativo entre os aços inoxidáveis dúplex e os inoxidáveis AISI 304L/316L

    Directory of Open Access Journals (Sweden)

    Marcelo Senatore

    2007-03-01

    Full Text Available Os aços inoxidáveis dúplex ferríticos-austeníticos fazem parte de uma classe de materiais com microestrutura bifásica, composta por uma matriz ferrítica e ilhas de austenita, com frações volumétricas aproximadamente iguais dessas fases. Essa classe de materiais é caracterizada por apresentar interessante combinação de elevadas propriedades mecânicas e de resistência à corrosão e, por isso, é considerada bastante versátil. Os aços inoxidáveis dúplex são, freqüentemente, utilizados nas indústrias química e petroquímica, de papel e celulose, siderúrgicas, alimentícias e de geração de energia. O presente trabalho estabelece um comparativo entre as propriedades físicas, mecânicas e de resistência à corrosão dos aços inoxidáveis duplex e os tradicionais aços inoxidáveis austeníticos AISI 304L e 316L, largamente utilizados na indústria brasileira. Resultados de ensaios laboratoriais e dados relevantes de experiências práticas desses materiais também são apresentados.Ferritic-austenitic duplex stainless steels are part of a class of material having a two-phase microestructure, comprised of a ferritic matrix and austenitic islands, with the volumetric fractions approximately the same in these phases. This class of material is characterized by the presentation of an interesting combination of high mechanical properties and corrosion resistance and is therefore considered quite versatile. The duplex stainless steels are often used in the chemical, petrochemical, pulp & paper and food industries, as well as in steel foundaries and energy power plants. This paper shows a comparison between the physical, mechanical and corrosion resistance properties of duplex stainless steels and the traditional austenitic stainless steels 304L and 316L, largely used in the Brazilian industry. Results of laboratory tests and relevant data on practical experiments on these materials are also presented.

  19. Effects of Thermal Aging on Material Properties, Stress Corrosion Cracking, and Fracture Toughness of AISI 316L Weld Metal

    Science.gov (United States)

    Lucas, Timothy; Forsström, Antti; Saukkonen, Tapio; Ballinger, Ronald; Hänninen, Hannu

    2016-08-01

    Thermal aging and consequent embrittlement of materials are ongoing issues in cast stainless steels, as well as duplex, and high-Cr ferritic stainless steels. Spinodal decomposition is largely responsible for the well-known "748 K (475 °C) embrittlement" that results in drastic reductions in ductility and toughness in these materials. This process is also operative in welds of either cast or wrought stainless steels where δ-ferrite is present. While the embrittlement can occur after several hundred hours of aging at 748 K (475 °C), the process is also operative at lower temperatures, at the 561 K (288 °C) operating temperature of a boiling water reactor (BWR), for example, where ductility reductions have been observed after several tens of thousands of hours of exposure. An experimental program was carried out in order to understand how spinodal decomposition may affect changes in material properties in Type 316L BWR piping weld metals. The study included material characterization, nanoindentation hardness, double-loop electrochemical potentiokinetic reactivation (DL-EPR), Charpy-V, tensile, SCC crack growth, and in situ fracture toughness testing as a function of δ-ferrite content, aging time, and temperature. SCC crack growth rates of Type 316L stainless steel weld metal under simulated BWR conditions showed an approximate 2 times increase in crack growth rate over that of the unaged as-welded material. In situ fracture toughness measurements indicate that environmental exposure can result in a reduction of toughness by up to 40 pct over the corresponding at-temperature air-tested values. Material characterization results suggest that spinodal decomposition is responsible for the degradation of material properties measured in air, and that degradation of the in situ properties may be a result of hydrogen absorbed during exposure to the high-temperature water environment.

  20. EFFECT OF NANOCRYSTALLINE AND TWIN BOUNDARIES ON CORROSION BEHAVIOR OF 316L STAINLESS STEEL USING SMAT

    Institute of Scientific and Technical Information of China (English)

    A.Q. Lü; Y. Zhang; Y. Li; G. Liu; Q.H. Zang; C.M. Liu

    2006-01-01

    By means of surface mechanical attrition treatment (SMAT), the grain size with a diameter of about 60nm formed at about 20μm depth and numerous mechanical twins at about 50μm depth from the treated surface were synthesized in 316L stainless steel because of the different distributions of strain and strain rate along depth orientation. For instance the maximum strain rate reached103-104s-1 on the top surface. The relationship between the microstructure and the corrosion property was studied in 0. 05M H2SO4+ 0.25M Na2SO4 aqueous solution, and the results show an extreme improvement of corrosion resistance owing to the appearance of twin boundaries and the obvious reduction in corrosion resistance attributed to the presence of nanocrystaline boundaries.

  1. Investigation on Porosity and Microhardness of 316L Stainless Steel Fabricated by Selective Laser Melting

    Directory of Open Access Journals (Sweden)

    Shahir Mohd Yusuf

    2017-02-01

    Full Text Available This study investigates the porosity and microhardness of 316L stainless steel samples fabricated by selective laser melting (SLM. The porosity content was measured using the Archimedes method and the advanced X-ray computed tomography (XCT scan. High densification level (≥99% with a low average porosity content (~0.82% were obtained from the Archimedes method. The highest porosity content in the XCT-scanned sample was ~0.61. However, the pores in the SLM samples for both cases (optical microscopy and XCT were not uniformly distributed. The higher average microhardness values in the SLM samples compared to the wrought manufactured counterpart are attributed to the fine microstructures from the localised melting and rapid solidification rate of the SLM process.

  2. Study of TiC+TiN Multiple Films On Type of 316L Stainless Steel

    Institute of Scientific and Technical Information of China (English)

    XUEQi; JINYong; HUDong-ping; HUANGBen-sheng; DENGBai-quan

    2004-01-01

    In this paper, the synthesis process of TiC+TiN multiple films on super-low-carbon stainless steels is reported. The TiC layer is coated as the first layer in the multiple film, the change of growth rate of the film on the 316L Stainlesss teel is not same as the one on carbides substrates, while the mole ratio of CH4 to TiCl4 (mCH4/TiCl4) is changed from 1.2 to 2.0. The Ti [C,N], as a kind of inter-layer between TiC and TiN layers, is helpful to improve the adhesion hetween the TiC and TiN layer. The cooling rate greatly influences the quality of the adhesion between the TiC+TiN film and substrates.

  3. Controlling the electrodeposition, morphology and structure of hydroxyapatite coating on 316L stainless steel.

    Science.gov (United States)

    Thanh, Dinh Thi Mai; Nam, Pham Thi; Phuong, Nguyen Thu; Que, Le Xuan; Anh, Nguyen Van; Hoang, Thai; Lam, Tran Dai

    2013-05-01

    Hydroxyapatite (HAp) coatings were prepared on 316L stainless steel (316LSS) substrates by electrochemical deposition in the solutions containing Ca(NO3)2·4H2O and NH4H2PO4 at different electrolyte concentrations. Along with the effect of precursor concentration, the influence of temperature and H2O2 content on the morphology, structure and composition of the coating was thoroughly discussed with the help of X-ray diffraction (XRD), Scanning electron microscopy (SEM), Fourier transform infrared (FTIR) spectra. The in vitro tests in simulated body fluids (SBF) were carried out and then the morphological and structural changes were estimated by SEM and electrochemical techniques (open circuit potential, polarization curves, Nyquist and Bode spectra measurements). Being simple and cost-effective, this method is advantageous for producing HAp implant materials with good properties/characteristics, aiming towards in vivo biomedical applications.

  4. A Shear Strain Route Dependency of Martensite Formation in 316L Stainless Steel.

    Science.gov (United States)

    Kang, Suk Hoon; Kim, Tae Kyu; Jang, Jinsung; Oh, Kyu Hwan

    2015-06-01

    In this study, the effect of simple shearing on microstructure evolution and mechanical properties of 316L austenitic stainless steel were investigated. Two different shear strain routes were obtained by twisting cylindrical specimens in the forward and backward directions. The strain-induced martensite phase was effectively obtained by alteration of the routes. Formation of the martensite phase clearly resulted in significant hardening of the steel. Grain-size reduction and strain-induced martensitic transformation within the deformed structures of the strained specimens were characterized by scanning electron microscopy - electron back-scattered diffraction, X-ray diffraction, and the TEM-ASTAR (transmission electron microscopy - analytical scanning transmission atomic resolution, automatic crystal orientation/phase mapping for TEM) system. Significant numbers of twin networks were formed by alteration of the shear strain routes, and the martensite phases were nucleated at the twin interfaces.

  5. The fracture and fragmentation behaviour of additively manufactured stainless steel 316L

    Science.gov (United States)

    Amott, R.; Harris, E. J.; Winter, R. E.; Stirk, S. M.; Chapman, D. J.; Eakins, D. E.

    2017-01-01

    Expanding cylinder experiments using a gas gun technique allow investigations into the ductility of metals and the fracture and fragmentation mechanisms that occur during rapid tensile failure. These experiments allow the radial strain-rate of the expansion to be varied in the range 102 to 104 s-1. Presented here is a comparative study of the fracture and fragmentation behaviour of rapidly expanded stainless steel 316L cylinders manufactured from either a wrought bar or additive manufacturing techniques. The results show that in the strain-rate regime studied, an additively manufactured cylinder failed at a higher strain and produced larger fragment widths when compared to cylinders manufactured from a wrought bar. In addition, an investigation into the role of macroscopic elongated voids that were introduced into the cylinder wall, at an angle of 45° to the cylinder radius, was undertaken. A comparison between experimental and simulated results (using the Eulerian hydrocode CTH) was also completed.

  6. Corrosion resistance improvement for 316L stainless steel coronary artery stents by trimethylsilane plasma nanocoatings.

    Science.gov (United States)

    Eric Jones, John; Chen, Meng; Yu, Qingsong

    2014-10-01

    To improve their corrosion resistance and thus long-term biocompatibility, 316L stainless steel coronary artery stents were coated with trimethylsilane (TMS) plasma coatings of 20-25 nm in thickness. Both direct current (DC) and radio-frequency (RF) glow discharges were utilized for TMS plasma coatings and additional NH₃/O₂ plasma treatment to tailor the surface properties. X-ray photoelectron spectroscopy (XPS) was used to characterize the coating surface chemistry. It was found that both DC and RF TMS plasma coatings had Si- and C-rich composition, and the O- and N-contents on the surfaces were substantially increased after NH₃/O₂ plasma treatment. Surface contact angle measurements showed that DC TMS plasma nanocoating with NH₃/O₂ plasma treatment generated very hydrophilic surface. The corrosion resistance of TMS plasma coated stents was evaluated through potentiodynamic polarization and electrochemical impedance spectroscopy (EIS) techniques. The potentiodynamic polarization demonstrated that the TMS plasma coated stents imparted higher corrosion potential and pitting potential, as well as lower corrosion current densities as compared with uncoated controls. The surface morphology of stents before and after potentiodynamic polarization testing was analyzed with scanning electron microscopy, which indicated less corrosion on coated stents than uncoated controls. It was also noted that, from EIS data, the hydrophobic TMS plasma nanocoatings showed stable impedance modulus at 0.1 Hz after 21 day immersion in an electrolyte solution. These results suggest improved corrosion resistance of the 316L stainless steel stents by TMS plasma nanocoatings and great promise in reducing and blocking metallic ions releasing into the bloodstream.

  7. Análisis térmico de soldadura GTAW sobre placa de acero AISI 316L empleando el método de elementos finitos GTAW welding thermal analysis on AISI 316L steel plate using the finite elements method

    Directory of Open Access Journals (Sweden)

    Juan A. Pozo-Morejón

    2011-09-01

    Full Text Available En el presente trabajo se realiza la modelación térmica de soldadura GTAW sobre placa de acero inoxidable AISI 316L. Se analizan los aspectos teóricos más relevantes a considerar durante la ejecución de un análisis de este tipo. En la simulación se emplea un software de análisis por elementos finitos de uso general y se enriquece una metodología, previamente desarrollada, para la modelación en 3D no lineal transitoria del proceso de soldeo. En dicha metodología se implementa una subrutina en lenguaje APDL, programada con el modelo volumétrico de fuente calor de doble elipsoide, en un sistema de coordenadas cartesiano. Se analiza la influencia del paso de tiempo seleccionado sobre los resultados de la simulación. Finalmente se valida la metodología enriquecida, en base a la correlación de los resultados del modelo respecto a los resultados experimentales.In the present work, thermal modeling of GTAW welding on AISI 316L stainless steel plate is presented. More relevant theoretical aspects to be considered during the implementation of an analysis of this type are discussed. For the simulation a general purpose finite element analysis software has been used. A previously developed methodology for 3D nonlinear transient modeling of welding process has also been improved. In this methodology a subroutine in APDL language is implemented, programmed with the double ellipsoid volumetric heat source model, in a Cartesian coordinated system. The influence of the selected time step on the simulation results is analyzed. The good correlation obtained among the results calculated by means of the model and the experimental data validates this improved methodology.

  8. Low friction and high strength of 316L stainless steel tubing for biomedical applications.

    Science.gov (United States)

    Amanov, Auezhan; Lee, Soo-Wohn; Pyun, Young-Sik

    2017-02-01

    We propose herein a nondestructive surface modification technique called ultrasonic nanocrystalline surface modification (UNSM) to increase the strength and to improve the tribological performance of 316L stainless steel (SS) tubing. Nanocrystallization along nearly the complete tube thickness of 200μm was achieved by UNSM technique that was confirmed by electron backscatter diffraction (EBSD). Nano-hardness of the untreated and UNSM-treated specimens was measured using a nanoindentation. Results revealed that a substantial increase in hardness was obtained for the UNSM-treated specimen that may be attributed to the nanocrystallization and refined grains. Stress-strain behavior of the untreated and UNSM-treated specimens was assessed by a 3-point bending test. It was found that the UNSM-treated specimen exhibited a much higher strength than that of the untreated specimen. In addition, the tribological behavior of the untreated and UNSM-treated specimens with an outer diameter (OD) of 1.6mm and an inner diameter (ID) of 1.2mm was investigated using a cylinder-on-cylinder (crossed tubes of equal radius) tribo-tester against itself under dry conditions at ambient temperature. The friction coefficient and wear resistance of the UNSM-treated specimen were remarkably improved compared to that of the untreated specimen. The significant increase in hardness after UNSM treatment is responsible for the improved friction coefficient and wear resistance of the tubing. Thus, the UNSM technique was found to be beneficial to improving the mechanical and tribological properties of 316L SS tubing for various potential biomedical applications, in particular for coronary artery stents.

  9. Adipose tissue-derived stem cell response to the differently processed 316L stainless steel substrates.

    Science.gov (United States)

    Faghihi, Shahab; Zia, Sonia; Taha, Masoumeh Fakhr

    2012-12-01

    Stainless steel (SS) is one of the most applicable materials in fabrication of cardiac implants. The aim of this study is to investigate the effect of atomic structure of polycrystalline stainless steel on the response of adipose tissue-derived stem cells (ADSCs). Samples are prepared from differently processed extruded rod and rolled sheet of 316L SS having different crystallographic structure. X-ray diffraction analysis indicated (200) and (111) orientations with distinct volume fractions in the specimens. Morphology and ADSCs behavior including adhesion, proliferation and differentiation are assessed. The expression of cardiac specific protein (cardiac troponin I) and genes of differentiating cardiomyocytes is analyzed by immunofluorescence and RT-PCR. The number of attached and grown cells on the rod sample is higher than the sheet sample also the scanning electron microscopy (SEM) analysis of ADSCs grown on the samples demonstrates higher cell density and spreading pattern on the surface of rod sample. In differentiated ADSCs on the rod sample the expression of all genes except ANF are detectable, while on the sheet sample only the MEF2C and β-MHC are expressed. This study shows that the cellular response is influenced by the crystal structure of the substrate therefore; the skill to alter the structure of substrate may lend itself to engineer a biomaterial which could be suitable for differentiation of stem cells into a definite lineage.

  10. Bone-like apatite formation on HA/316L stainless steel composite surface in simulated body fluid

    Institute of Scientific and Technical Information of China (English)

    FAN Xin; CHEN Jian; ZOU Jian-peng; WAN Qian; ZHOU Zhong-cheng; RUAN Jian-ming

    2009-01-01

    HA/316L stainless steel(316L SS) biocomposites were prepared by hot-pressing technique. The formation of bone-like apatite on the biocomposite surfaces in simulated body fluid(SBF) was analyzed by digital pH meter, plasma emission spectrometer, scanning electron microscope(SEM) and energy dispersive X-ray energy spectrometer(EDX). The results indicate that the pH value in SBF varies slightly during the immersion. It is a dynamic process of dissolution-precipitation for the formation of apatite on the surface. With prolonging immersion time, Ca and P ion concentrations increase gradually, and then approach equilibrium. The bone-like apatite layer forms on the composites surface, which possesses benign bioactivity and favorable biocompatibility and achieves osseointegration, and can provide firm fixation between HA60/316L SS composite implants and human body bone.

  11. Effect of Mercury Velocity on Corrosion of Type 316L Stainless Steel in a Thermal Convection Loop

    Energy Technology Data Exchange (ETDEWEB)

    Pawel, SJ

    2001-03-23

    Two 316L thermal convection loops (TCLs) containing several types of 316L specimens circulated mercury continuously for 2000 h at a maximum temperature of 300 C. Each TCL was fitted with a venturi-shaped reduced section near the top of the hot leg for the purpose of locally increasing the Hg velocity. Results suggest that an increase in velocity from about 1.2 m/min (bulk flow) to about 5 mmin (reduced section) had no significant impact on compatibility of 316L with Hg. In addition, various surface treatments such as gold-plating, chemical etching, polishing, and steam cleaning resulted in little or no influence on compatibility of 316L with Hg when compared to nominal mill-annealed/surface-ground material. A sensitizing heat treatment also had little/no effect on compatibility of 316L with Hg for the bulk specimen, although intergranular attack was observed around the specimen holes in each case. It was determined that carburization of the hole area had occurred as a result of the specimen fabrication process potentially rendering the specimens susceptible to corrosion by Hg at these locations. To avoid sensitization-related compatibility issues for SNS components, selection of low carbon grades of stainless steel and control of the fabrication process is recommended.

  12. Caracterización microestructural de uniones soldadas de acero AISI 316L en tuberías

    Directory of Open Access Journals (Sweden)

    Tomás H. Fernández-Columbié

    2016-03-01

    Full Text Available Se analizó el comportamiento microestructural de uniones soldadas de acero AISI 316L empleado en la fabricación de tuberías, las cuales se ven afectadas por agrietamiento en el cordón de soldadura. Se emplearon electrodos revestidos de acero inoxidables de los tipos E 309–16; 310–16 y E 316L–16, según norma de la AWS, los que fueron evaluados por su depósito en uniones a tope preparadas con biseles en V, soldadas por un solo lado del material de la tubería, así como la selección y preparación de muestra en zonas donde la tubería presenta daños mecánicos, fisuras y corrosión severa con pérdida del espesor de pared crítica para soportar las presiones de trabajo. Se caracterizó la microestructura de la zona fundida y la zona de influencia térmica de cada cordón luego de realizado el proceso de soldadura. Se concluye que la soldadura con electrodos del tipo E 309-16 y del tipo E 316-16 no son recomendables debido a que se obtiene una microestructura sensible al agrietamiento.

  13. Influence of the cutting parameters on flank wear of coated inserts during turning of AISI 316L

    Directory of Open Access Journals (Sweden)

    Yusimit Zamora Hernández

    2015-03-01

    Full Text Available (Received: 2015/01/20 - Accepted: 2015/03/25The continuous improvement of manufacturing processes is critical to achieve optimum levels of productivity, quality and cut production of components and products. This research aims to determine the cutting tool flank wearing progression, during a high speed dry turning, for AISI 316L steel parts. Experimental data were acquired using two cutting feed levels, two material levels, three cutting speeds, and four principal cutting times. A scanning electron microscope (SEM was used to measure and analyze the wear of the cutting tools. Results were compared using analysis of variance and multiple regression for describing the relation between the variables used in the study. The analysis showed that the three layers coating insert did not exceed the end of life wearing criterion, while the one layer insert suffered a catastrophic wearing at the highest cutting speed. It was found that a relation exists between the experimental data and the predicted values for flank wear with a general average error of 4.1182%.

  14. Resistência à corrosão de junta dissimilar soldada pelo processo TIG composta pelos aços inoxidáveis AISI 316L e AISI 444

    Directory of Open Access Journals (Sweden)

    Luis Henrique Guilherme

    2014-03-01

    Full Text Available O aço inoxidável AISI 444 tornou-se uma opção para substituir a liga AISI 316L devido ao seu menor custo e satisfatória resistência à corrosão. Entretanto, o uso da liga AISI 444 no feixe tubular de trocadores de calor acarreta na soldagem de uma junta dissimilar. O presente estudo teve por objetivo avaliar a resistência à corrosão da junta tubo-espelho soldada pelo processo TIG composta pelas ligas AISI 316L e AISI 444. A manufatura das amostras consistiu em replicar o projeto da junta tubo-espelho de trocadores de calor. Realizou-se em juntas soldadas ensaios de sensitização, perda de massa por imersão desde a temperatura ambiente até 90 ºC, e ensaios eletroquímicos de polarização potenciodinâmica nos eletrólitos 0,5 mol/L de HCl e 0,5 mol/L de H2SO4. Os resultados mostraram que a junta dissimilar sofreu corrosão galvânica com maior degradação na zona afetada pelo calor (ZAC do tubo AISI 444. Porém, os mecanismos de corrosão localizada (pite e intergranular demonstraram ser mais ativos para a liga AISI 316L. Conclui-se que a junta dissimilar apresentou melhor resistência à corrosão do que a junta soldada composta unicamente pela liga AISI 316L em temperaturas de até 70 ºC, conforme as condições observadas neste trabalho.

  15. Low-temperature plasma nitriding of sintered PIM 316L austenitic stainless steel

    Energy Technology Data Exchange (ETDEWEB)

    Mendes, Aecio Fernando; Scheuer, Cristiano Jose; Joanidis, Ioanis Labhardt; Cardoso, Rodrigo Perito; Mafra, Marcio; Klein, Aloisio Nelmo; Brunatto, Silvio Francisco, E-mail: brunatto@ufpr.br [Universidade Federal do Parana (UFPR), Curitiba, PR (Brazil). Dept. de Engenharia Mecanica. Grupo de Tecnologia de Fabricacao Assistida pro Plasma e Metalurgia do Po

    2014-08-15

    This work reports experimental results on sintered PIM 316L stainless steel low-temperature plasma nitriding. The effect of treatment temperature and time on process kinetics, microstructure and surface characteristics of the nitrided samples were investigated. Nitriding was carried out at temperatures of 350, 380, 410 and 440 °C , and times of 4, 8 and 16 h, using a gas mixture composed by 60% N2 + 20% H2 + 20% Ar, at a gas flow rate of 5.00 X 10{sup 6} Nm{sup 3-1}, and a pressure of 800 Pa. The treated samples were characterized by scanning electron microscopy, X-ray diffractometry and microhardness measurements. Results indicate that low-temperature plasma nitriding is a diffusion controlled process. The calculated activation energy for nitrided layer growth was 111.4 kJmol{sup -1}. Apparently precipitation-free layers were produced in this study. It was also observed that the higher the treatment temperature and time the higher is the obtained surface hardness. Hardness up to 1343 HV{sub 0.025} was verified for samples nitrided at 440 °C. Finally, the characterization of the treated surface indicates the formation of cracks, which were observed in regions adjacent to the original pores after the treatment. (author)

  16. Study of the Mechanical Properties of a Nanostructured Surface Layer on 316L Stainless Steel

    Directory of Open Access Journals (Sweden)

    F. C. Lang

    2016-01-01

    Full Text Available A nanostructured surface layer (NSSL was generated on a 316L stainless steel plate through surface nanocrystallization (SNC. The grains of the surface layer were refined to nanoscale after SNC treatment. Moreover, the microstructure and mechanical properties of NSSL were analyzed with a transmission electron microscope (TEM and scanning electron microscope (SEM, through nanoindentation, and through reverse analysis of finite element method (FEM. TEM results showed that the grains in the NSSL measured 8 nm. In addition, these nanocrystalline grains took the form of random crystallographic orientation and were roughly equiaxed in shape. In situ SEM observations of the tensile process confirmed that the motions of the dislocations were determined from within the material and that the motions were blocked by the NSSL, thus improving overall yielding stress. Meanwhile, the nanohardness and the elastic modulus of the NSSL, as well as those of the matrix, were obtained with nanoindentation technology. The reverse analysis of FEM was conducted with MARC software, and the process of nanoindentation on the NSSL and the matrix was simulated. The plastic mechanical properties of NSSL can be derived from the simulation by comparing the results of the simulation and of actual nanoindentation.

  17. Effect of nitrogen on creep properties of type 316L stainless steel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, D.W.; Lee, Y.K.; Kuk, I.H.; Ryu, W.S. [Korea Atomic Energy Research Institute, Taejon (Korea)

    1999-03-01

    The effect of nitrogen on the creep properties of type 316L stainless steels with three different nitrogen contents from 0.04 to 0.15% was investigated. The plate was solution treated for 1 hr at 1100 deg C and then water quenched. Specimens were obtained from the plate parallel to the rolling direction. The geometry of specimen was 4mm diameter and 30mm gauge length. Creep tests were carried out using constant-load single-lever machines in the initial stress range from 120 to 380MPa at 550, 600 and 650 deg C and in air. The temperature deviation along the gauge length of the specimen was strictly controlled less than {+-}2 deg C. The time to rupture increased and the minimum creep strain rate decreased with the addition of nitrogen. On the other hand, the rupture elongation and fracture mode was not strongly influenced by the nitrogen content. The effect of nitrogen content on the creep properties were found to be more pronounced at higher temperatures. The intergranular fracture mode was found in all specimens and increased with decreasing applied stress. (author). 7 refs., 41 figs.

  18. Macrophage responses to 316L stainless steel and cobalt chromium alloys with different surface topographies.

    Science.gov (United States)

    Anderson, Jordan A; Lamichhane, Sujan; Mani, Gopinath

    2016-11-01

    The surface topography of a biomaterial plays a vital role in determining macrophage interactions and influencing immune response. In this study, we investigated the effect of smooth and microrough topographies of commonly used metallic biomaterials such as 316 L stainless steel (SS) and cobalt-chromium (CoCr) alloys on macrophage interactions. The macrophage adhesion was greater on CoCr compared to SS, irrespective of their topographies. The macrophage activation and the secretion of most pro-inflammatory cytokines (TNF-α, IL-6, and IP-10) were greater on microrough surfaces than on smooth surfaces by day-1. However, by day-2, the macrophage activation on smooth surfaces was also significantly increased up to the same level as observed on the microrough surfaces, with more amount of cytokines secreted. The secretion of anti-inflammatory cytokine (IL-10) was significantly increased from day-1 to day-2 on all the alloy surfaces with the effect most prominently observed on microrough surfaces. The production of nitric oxide by the macrophages did not show any major substrate-dependent effect. The foreign body giant cells formed by macrophages were least observed on the microrough surfaces of CoCr. Thus, this study demonstrated that the nature of material (SS or CoCr) and their surface topographies (smooth or microrough) strongly influence the macrophage responses. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 104A: 2658-2672, 2016.

  19. Galvanic deposition and characterization of brushite/hydroxyapatite coatings on 316L stainless steel.

    Science.gov (United States)

    Blanda, Giuseppe; Brucato, Valerio; Pavia, Francesco Carfì; Greco, Silvia; Piazza, Salvatore; Sunseri, Carmelo; Inguanta, Rosalinda

    2016-07-01

    In this work, brushite and brushite/hydroxyapatite (BS, CaHPO4·H2O; HA, Ca10(PO4)6(OH)2) coatings were deposited on 316L stainless steel (316LSS) from a solution containing Ca(NO3)2·4H2O and NH4H2PO4 by a displacement reaction based on a galvanic contact, where zinc acts as sacrificial anode. Driving force for the cementation reaction arises from the difference in the electrochemical standard potentials of two different metallic materials (316LSS and Zn) immersed in an electrolyte, so forming a galvanic contact leading to the deposition of BS/HA on nobler metal. We found that temperature and deposition time affect coating features (morphology, structure, and composition). Deposits were characterized by means of several techniques. The morphology was investigated by scanning electron microscopy, the elemental composition was obtained by X-ray energy dispersive spectroscopy, whilst the structure was identified by Raman spectroscopy and X-ray diffraction. BS was deposited at all investigated temperatures covering the 316LSS surface. At low and moderate temperature, BS coatings were compact, uniform and with good crystalline degree. On BS layers, HA crystals were obtained at 50°C for all deposition times, while at 25°C, its presence was revealed only after long deposition time. Electrochemical studies show remarkable improvement in corrosion resistance.

  20. Dynamic Mechanical Response of Biomedical 316L Stainless Steel as Function of Strain Rate and Temperature.

    Science.gov (United States)

    Lee, Woei-Shyan; Chen, Tao-Hsing; Lin, Chi-Feng; Luo, Wen-Zhen

    2011-01-01

    A split Hopkinson pressure bar is used to investigate the dynamic mechanical properties of biomedical 316L stainless steel under strain rates ranging from 1 × 10(3) s(-1) to 5 × 10(3) s(-1) and temperatures between 25°C and 800°C. The results indicate that the flow stress, work-hardening rate, strain rate sensitivity, and thermal activation energy are all significantly dependent on the strain, strain rate, and temperature. For a constant temperature, the flow stress, work-hardening rate, and strain rate sensitivity increase with increasing strain rate, while the thermal activation energy decreases. Catastrophic failure occurs only for the specimens deformed at a strain rate of 5 × 10(3) s(-1) and temperatures of 25°C or 200°C. Scanning electron microscopy observations show that the specimens fracture in a ductile shear mode. Optical microscopy analyses reveal that the number of slip bands within the grains increases with an increasing strain rate. Moreover, a dynamic recrystallisation of the deformed microstructure is observed in the specimens tested at the highest temperature of 800°C.

  1. Reduced graphene oxide growth on 316L stainless steel for medical applications.

    Science.gov (United States)

    Cardenas, L; MacLeod, J; Lipton-Duffin, J; Seifu, D G; Popescu, F; Siaj, M; Mantovani, D; Rosei, F

    2014-08-07

    We report a new method for the growth of reduced graphene oxide (rGO) on the 316L alloy of stainless steel (SS) and its relevance for biomedical applications. We demonstrate that electrochemical etching increases the concentration of metallic species on the surface and enables the growth of rGO. This result is supported through a combination of Raman spectroscopy, X-ray photoelectron spectroscopy (XPS), atomic force microscopy (AFM), scanning electron microscopy (SEM), density functional theory (DFT) calculations and static water contact angle measurements. Raman spectroscopy identifies the G and D bands for oxidized species of graphene at 1595 cm(-1) and 1350 cm(-1), respectively, and gives an ID/IG ratio of 1.2, indicating a moderate degree of oxidation. XPS shows -OH and -COOH groups in the rGO stoichiometry and static contact angle measurements confirm the wettability of rGO. SEM and AFM measurements were performed on different substrates before and after coronene treatment to confirm rGO growth. Cell viability studies reveal that these rGO coatings do not have toxic effects on mammalian cells, making this material suitable for biomedical and biotechnological applications.

  2. Microbiological test results using three urine pretreatment regimes with 316L stainless steel

    Science.gov (United States)

    Huff, Timothy L.

    1993-01-01

    Three urine pretreatments, (1) Oxone (Dupont) and sulfuric acid, (2) sodium hypochlorite and sulfuric acid, (3) and ozone, were studied for their ability to reduce microbial levels in urine and minimize surface attachment to 316L stainless steel coupons. Urine samples inoculated with Bacillus insolitus and a filamentous mold, organisms previously recovered from the vapor compression distillation subsystem of NASA Space Station Freedom water recovery test were tested in glass corrosion cells containing base or weld metal coupons. Microbial levels, changes in pH, color, turbidity, and odor of the fluid were monitored over the course of the 21-day test. Specimen surfaces were examined by scanning electron microscopy at completion of the test for microbial attachment. Ozonated urine samples were less turbid and had lower microbial levels than controls or samples receiving other pretreatments. Base metal coupons receiving pretreatment were relatively free of attached bacteria. However, well-developed biofilms were found in the heat-affected regions of welded coupons receiving Oxone and hypochlorite pretreatments. Few bacteria were observed in the same regions of the ozone pretreatment sample.

  3. Fabrication of low-cost, cementless femoral stem 316L stainless steel using investment casting technique.

    Science.gov (United States)

    Baharuddin, Mohd Yusof; Salleh, Sh-Hussain; Suhasril, Andril Arafat; Zulkifly, Ahmad Hafiz; Lee, Muhammad Hisyam; Omar, Mohd Afian; Abd Kader, Ab Saman; Mohd Noor, Alias; A Harris, Arief Ruhullah; Abdul Majid, Norazman

    2014-07-01

    Total hip arthroplasty is a flourishing orthopedic surgery, generating billions of dollars of revenue. The cost associated with the fabrication of implants has been increasing year by year, and this phenomenon has burdened the patient with extra charges. Consequently, this study will focus on designing an accurate implant via implementing the reverse engineering of three-dimensional morphological study based on a particular population. By using finite element analysis, this study will assist to predict the outcome and could become a useful tool for preclinical testing of newly designed implants. A prototype is then fabricated using 316L stainless steel by applying investment casting techniques that reduce manufacturing cost without jeopardizing implant quality. The finite element analysis showed that the maximum von Mises stress was 66.88 MPa proximally with a safety factor of 2.39 against endosteal fracture, and micromotion was 4.73 μm, which promotes osseointegration. This method offers a fabrication process of cementless femoral stems with lower cost, subsequently helping patients, particularly those from nondeveloped countries.

  4. Human aortic endothelial cell response to 316L stainless steel material microstructure.

    Science.gov (United States)

    Choubey, Animesh; Marton, Denes; Sprague, Eugene A

    2009-10-01

    The role of metal microstructure (e.g. grain sizes) in modulating cell adherence behavior is not well understood. This study investigates the effect of varying grain sizes of 316L stainless steel (SS) on the attachment and spreading of human aortic endothelial cells (HAECs). Four different grain size samples; from 16 to 66 microm (ASTM 9.0-4.9) were sectioned from sheets. Grain structure was revealed by polishing and etching with glycergia. Contact angle measurement was done to assess the hydrophilicity of the specimens. Atomic force microscopy (AFM) and X-ray photoelectron spectroscopy (XPS) were used to characterize the roughness and surface chemistry of the specimens. Cells were seeded on mechanically polished and chemically etched specimens followed by identification of activated focal adhesion sites using fluorescently tagged anti-pFAK (phosphorylated focal adhesion kinase). The 16 microm grain size etched specimens had significantly (P < 0.01) higher number of cells attached per cm(2) than other specimens, which may be attributed to the greater grain boundary area and associated higher surface free energy. This study shows that the underlying material microstructure may influence the HAEC behavior and may have important implications in endothelialization.

  5. Corrosion kinetics of 316L stainless steel bipolar plate with chromiumcarbide coating in simulated PEMFC cathodic environment

    Science.gov (United States)

    Huang, N. B.; Yu, H.; Xu, L. S.; Zhan, S.; Sun, M.; Kirk, Donald W.

    Stainless steel with chromium carbide coating is an ideal candidate for bipolar plates. However, the coating still cannot resist the corrosion of a proton exchange membrane fuel cell (PEMFC) environment. In this work, the corrosion kinetics of 316L stainless steel with chromium carbide is investigated in simulated PEMFC cathodic environment by combining electrochemical tests with morphology and microstructure analysis. SEM results reveal that the steel's surface is completely coated by Cr and chromium carbide but there are pinholes in the coating. After the coated 316L stainless steel is polarized, the diffraction peak of Fe oxide is found. EIS results indicate that the capacitive resistance and the reaction resistance first slowly decrease (2-32 h) and then increase. The potentiostatic transient curve declines sharply within 2000 s and then decreases slightly. The pinholes, which exist in the coating, result in pitting corrosion. The corrosion kinetics of the coated 316L stainless steel are modeled and accords the following equation: i0 = 7.6341t-0.5, with the corrosion rate controlled by ion migration in the pinholes.

  6. Electrochemical study of Type 304 and 316L stainless steels in simulated body fluids and cell cultures.

    Science.gov (United States)

    Tang, Yee-Chin; Katsuma, Shoji; Fujimoto, Shinji; Hiromoto, Sachiko

    2006-11-01

    The electrochemical corrosion behaviour of Type 304 and 316L stainless steels was studied in Hanks' solution, Eagle's minimum essential medium (MEM), serum containing medium (MEM with 10% of fetal bovine serum) without cells, and serum containing medium with cells over a 1-week period. Polarization resistance measurements indicated that the stainless steels were resistant to Hanks' and MEM solutions. Type 304 was more susceptible to pitting corrosion than Type 316L in Hanks' and MEM solutions. The uniform corrosion resistance of stainless steels, determined by R(p), was lower in culturing medium than in Hanks' and MEM. The low corrosion resistance was due to surface passive film with less protective to reveal high anodic dissolution rate. When cells were present, the initial corrosion resistance was low, but gradually increased after 3 days, consistent with the trend of cell coverage. The presence of cells was found to suppress the cathodic reaction, that is, oxygen reduction, and increase the uniform corrosion resistance as a consequence. On the other hand, both Type 304 and 316L stainless steels became more susceptible to pitting corrosion when they were covered with cells.

  7. Ion Beam Analysis, structure and corrosion studies of nc-TiN/a-Si{sub 3}N{sub 4} nanocomposite coatings deposited by sputtering on AISI 316L

    Energy Technology Data Exchange (ETDEWEB)

    García, J. [Departamento de Ingeniería de Proyectos, CUCEI, Universidad de Guadalajara, J. Guadalupe Zuno 48, Los Belenes, Zapopan, Jal. 45101 (Mexico); Canto, C.E. [Instituto de Física, UNAM, Avenida de la Investigación S/N, Coyoacán, México, D.F. 04510 (Mexico); Flores, M. [Departamento de Ingeniería de Proyectos, CUCEI, Universidad de Guadalajara, J. Guadalupe Zuno 48, Los Belenes, Zapopan, Jal. 45101 (Mexico); Andrade, E., E-mail: andrade@fisica.unam.mx [Instituto de Física, UNAM, Avenida de la Investigación S/N, Coyoacán, México, D.F. 04510 (Mexico); Rodríguez, E.; Jiménez, O. [Departamento de Ingeniería de Proyectos, CUCEI, Universidad de Guadalajara, J. Guadalupe Zuno 48, Los Belenes, Zapopan, Jal. 45101 (Mexico); Solis, C.; Lucio, O.G. de [Instituto de Física, UNAM, Avenida de la Investigación S/N, Coyoacán, México, D.F. 04510 (Mexico); Rocha, M.F. [ESIME-Z, Instituto Politécnico Nacional, ALM Zacatenco, México, D.F. 07738 (Mexico)

    2014-07-15

    In this work, nanocomposite coatings of nc-TiN/a-Si{sub 3}N{sub 4}, were deposited on AISI 316L stainless steel substrate by a DC and RF reactive magnetron co-sputtering technique using an Ar–N{sub 2} plasma. The structure of the coatings was characterized by means of XRD (X-ray Diffraction). The substrate and coating corrosion resistance were evaluated by potentiodynamic polarization using a Ringer solution as electrolyte. Corrosion tests were conducted with the purpose to evaluate the potential of this coating to be used on biomedical alloys. IBA (Ion Beam Analysis) techniques were applied to measure the elemental composition profiles of the films and, XPS (X-ray Photoelectron Spectroscopy) were used as a complementary technique to obtain information about the compounds present in the films. The nanocomposite coatings of nc-TiN/a-Si{sub 3}N{sub 4} show crystalline (TiN) and amorphous (Si{sub 3}N{sub 4}) phases which confer a better protection against the corrosion effects compared with that of the AISI 316L.

  8. Effect of Zr, Nb and Ti addition on injection molded 316L stainless steel for bio-applications: Mechanical, electrochemical and biocompatibility properties.

    Science.gov (United States)

    Gulsoy, H Ozkan; Pazarlioglu, Serdar; Gulsoy, Nagihan; Gundede, Busra; Mutlu, Ozal

    2015-11-01

    The research investigated the effect of Zr, Nb and Ti additions on mechanical, electrochemical properties and biocompatibility of injection molded 316L stainless steel. Addition of elemental powder is promoted to get high performance of sintered 316L stainless steels. The amount of additive powder plays a role in determining the sintered microstructure and all properties. In this study, 316L stainless steel powders used with the elemental Zr, Nb and Ti powders. A feedstock containing 62.5 wt% powders loading was molded at different injection molded temperature. The binders were completely removed from molded components by solvent and thermal debinding at different temperatures. The debinded samples were sintered at 1350°C for 60 min. Mechanical, electrochemical property and biocompatibility of the sintered samples were performed mechanical, electrochemical, SBF immersion tests and cell culture experiments. Results of study showed that sintered 316L and 316L with additives samples exhibited high corrosion properties and biocompatibility in a physiological environment.

  9. Laser Rapid Manufacturing of Stainless Steel 316L/Inconel718 Functionally Graded Materials: Microstructure Evolution and Mechanical Properties

    Directory of Open Access Journals (Sweden)

    Dongjiang Wu

    2010-01-01

    Full Text Available Two patterns of functionally graded materials (FGMs were successfully fabricated whose compositions gradually varied from 100% stainless steel 316L to 100% Inconel718 superalloy using laser engineered net shaping process. The microstructure characterization, composition analysis, and microhardness along the graded direction were investigated. The comparison revealed the distinctions in solidification behavior, microstructure evolution of two patterns. In the end, the abrasive wear resistance of the material was investigated.

  10. Microstructure Evolution and Cracking Control of 316L Stainless Steel Manufactured by Multi-layer Laser Cladding

    Institute of Scientific and Technical Information of China (English)

    SONGJian-li; DENGQi-lin; HUDe-jin; SUNKang-kai; ZHOUGuang-cai

    2004-01-01

    Multi-layer laser cladding manufacturing is a newly developed rapid manufacturing technology. It is a powerful tool for direct fabrication of three-dimensional fully dense metal components and part repairing. In this paper, the microstructure evolution and properties of 316L stainless steel deposited with this technology was investigated, compact components with properties similar to the as-cast and wrought annealed material was obtained. Cracking was eliminated by introducing of supersonic vibration and application of parameter adjustment technologies.

  11. The Effect of Constant and Pulsed Current Gas Tungsten Arc Welding on Joint Properties of 2205 Duplex Stainless Steel to 316L Austenitic Stainless Steel

    Science.gov (United States)

    Neissi, R.; Shamanian, M.; Hajihashemi, M.

    2016-05-01

    In this study, dissimilar 316L austenitic stainless steel/2205 duplex stainless steel (DSS) joints were fabricated by constant and pulsed current gas tungsten arc welding process using ER2209 DSS as a filler metal. Microstructures and joint properties were characterized using optical and electron scanning microscopy, tensile, Charpy V-notch impact and micro-hardness tests, and cyclic polarization measurements. Microstructural observations confirmed the presence of chromium nitride and delta ferrite in the heat-affected zone of DSS and 316L, respectively. In addition, there was some deviation in the austenite/ferrite ratio of the surface welding pass in comparison to the root welding pass. Besides having lower pitting potential, welded joints produced by constant current gas tungsten arc welding process, consisted of some brittle sigma phase precipitates, which resulted in some impact energy reduction. The tensile tests showed high tensile strength for the weld joints in which all the specimens were broken in 316L base metal.

  12. A mechanism for the enhanced attachment and proliferation of fibroblasts on anodized 316L stainless steel with nano-pit arrays.

    Science.gov (United States)

    Ni, Siyu; Sun, Linlin; Ercan, Batur; Liu, Luting; Ziemer, Katherine; Webster, Thomas J

    2014-08-01

    In this study, 316L stainless steel with tunable nanometer pit sizes (0, 25, 50, and 60 nm) were fabricated by an anodization procedure in an ethylene glycol electrolyte solution containing 5 vol % perchloric acid. The surface morphology and elemental composition of the 316L stainless steel were characterized by scanning electron microscopy (SEM), atomic force microscopy (AFM), and X-ray photoelectron spectroscopy (XPS). The nano-pit arrays on all of the 316L stainless steel samples were in a regular arrangement. The surface properties of the 316L stainless steel nano-pit surface showed improved wettability properties as compared with the untreated 316L stainless steel, as demonstrated by the lower contact angles which dropped from 83.0° to 28.6 to 45.4°. The anodized 316L stainless steel surfaces with 50 nm and 60 nm diameter pits were also more rough at the nanoscale. According to MTT assays, compared with unanodized (that is, nano-smooth) surfaces, the 50 and 60 nm diameter nano-pit surfaces dramatically enhanced initial human dermal fibroblast attachment and growth for up to 3 days in culture. Mechanistically, this study also provided the first evidence of greater select protein adsorption (specifically, vitronectin and fibronectin which have been shown to enhance fibroblast adhesion) on the anodized 316L stainless steel compared with unanodized stainless steel. Such nano-pit surfaces can be designed to support fibroblast growth and, thus, improve the use of 316L stainless steel for various implant applications (such as for enhanced skin healing for amputee devices and for percutaneous implants).

  13. Galvanic deposition and characterization of brushite/hydroxyapatite coatings on 316L stainless steel

    Energy Technology Data Exchange (ETDEWEB)

    Blanda, Giuseppe [Laboratorio di Chimica Fisica Applicata, Dipartimento di Ingegneria Chimica Gestionale Informatica Meccanica, Università di Palermo, Viale delle Scienze, 90128 Palermo (Italy); Brucato, Valerio; Pavia, Francesco Carfì; Greco, Silvia [Dipartimento di Ingegneria Civile, Ambientale, Aerospaziale, dei Materiali, Università di Palermo, Viale delle Scienze, 90128 Palermo (Italy); Piazza, Salvatore; Sunseri, Carmelo [Laboratorio di Chimica Fisica Applicata, Dipartimento di Ingegneria Chimica Gestionale Informatica Meccanica, Università di Palermo, Viale delle Scienze, 90128 Palermo (Italy); Inguanta, Rosalinda, E-mail: rosalinda.inguanta@unipa.it [Laboratorio di Chimica Fisica Applicata, Dipartimento di Ingegneria Chimica Gestionale Informatica Meccanica, Università di Palermo, Viale delle Scienze, 90128 Palermo (Italy)

    2016-07-01

    In this work, brushite and brushite/hydroxyapatite (BS, CaHPO{sub 4}·H{sub 2}O; HA, Ca{sub 10}(PO{sub 4}){sub 6}(OH){sub 2}) coatings were deposited on 316L stainless steel (316LSS) from a solution containing Ca(NO{sub 3}){sub 2}·4H{sub 2}O and NH{sub 4}H{sub 2}PO{sub 4} by a displacement reaction based on a galvanic contact, where zinc acts as sacrificial anode. Driving force for the cementation reaction arises from the difference in the electrochemical standard potentials of two different metallic materials (316LSS and Zn) immersed in an electrolyte, so forming a galvanic contact leading to the deposition of BS/HA on nobler metal. We found that temperature and deposition time affect coating features (morphology, structure, and composition). Deposits were characterized by means of several techniques. The morphology was investigated by scanning electron microscopy, the elemental composition was obtained by X-ray energy dispersive spectroscopy, whilst the structure was identified by Raman spectroscopy and X-ray diffraction. BS was deposited at all investigated temperatures covering the 316LSS surface. At low and moderate temperature, BS coatings were compact, uniform and with good crystalline degree. On BS layers, HA crystals were obtained at 50 °C for all deposition times, while at 25 °C, its presence was revealed only after long deposition time. Electrochemical studies show remarkable improvement in corrosion resistance. - Highlights: • Brushite/hydroxyapatite coatings were obtained by a galvanic deposition method. • Galvanic deposition is simple and cheap and does not require external power supply. • Temperature is a key parameter to control composition and morphology of coatings. • Ca/P ratio changes with deposition time, from about 1 up to an optimum value of 1.7. • Compact and adherent layer covering substrate surface were obtained on 316LSS.

  14. The effect of hydrogen peroxide on uranium oxide films on 316L stainless steel

    Science.gov (United States)

    Wilbraham, Richard J.; Boxall, Colin; Goddard, David T.; Taylor, Robin J.; Woodbury, Simon E.

    2015-09-01

    For the first time the effect of hydrogen peroxide on the dissolution of electrodeposited uranium oxide films on 316L stainless steel planchets (acting as simulant uranium-contaminated metal surfaces) has been studied. Analysis of the H2O2-mediated film dissolution processes via open circuit potentiometry, alpha counting and SEM/EDX imaging has shown that in near-neutral solutions of pH 6.1 and at [H2O2] ⩽ 100 μmol dm-3 the electrodeposited uranium oxide layer is freely dissolving, the associated rate of film dissolution being significantly increased over leaching of similar films in pH 6.1 peroxide-free water. At H2O2 concentrations between 1 mmol dm-3 and 0.1 mol dm-3, formation of an insoluble studtite product layer occurs at the surface of the uranium oxide film. In analogy to corrosion processes on common metal substrates such as steel, the studtite layer effectively passivates the underlying uranium oxide layer against subsequent dissolution. Finally, at [H2O2] > 0.1 mol dm-3 the uranium oxide film, again in analogy to common corrosion processes, behaves as if in a transpassive state and begins to dissolve. This transition from passive to transpassive behaviour in the effect of peroxide concentration on UO2 films has not hitherto been observed or explored, either in terms of corrosion processes or otherwise. Through consideration of thermodynamic solubility product and complex formation constant data, we attribute the transition to the formation of soluble uranyl-peroxide complexes under mildly alkaline, high [H2O2] conditions - a conclusion that has implications for the design of both acid minimal, metal ion oxidant-free decontamination strategies with low secondary waste arisings, and single step processes for spent nuclear fuel dissolution such as the Carbonate-based Oxidative Leaching (COL) process.

  15. Mechanical and physical behavior of newly developed functionally graded materials and composites of stainless steel 316L with calcium silicate and hydroxyapatite.

    Science.gov (United States)

    Ataollahi Oshkour, Azim; Pramanik, Sumit; Mehrali, Mehdi; Yau, Yat Huang; Tarlochan, Faris; Abu Osman, Noor Azuan

    2015-09-01

    This study aimed to investigate the structural, physical and mechanical behavior of composites and functionally graded materials (FGMs) made of stainless steel (SS-316L)/hydroxyapatite (HA) and SS-316L/calcium silicate (CS) employing powder metallurgical solid state sintering. The structural analysis using X-ray diffraction showed that the sintering at high temperature led to the reaction between compounds of the SS-316L and HA, while SS-316L and CS remained intact during the sintering process in composites of SS-316L/CS. A dimensional expansion was found in the composites made of 40 and 50 wt% HA. The minimum shrinkage was emerged in 50 wt% CS composite, while the maximum shrinkage was revealed in samples with pure SS-316L, HA and CS. Compressive mechanical properties of SS-316L/HA decreased sharply with increasing of HA content up to 20 wt% and gradually with CS content up to 50 wt% for SS-316L/CS composites. The mechanical properties of the FGM of SS-316L/HA dropped with increase in temperature, while it was improved for the FGM of SS-316L/CS with temperature enhancement. It has been found that the FGMs emerged a better compressive mechanical properties compared to both the composite systems. Therefore, the SS-316L/CS composites and their FGMs have superior compressive mechanical properties to the SS-316L/HA composites and their FGMs and also the newly developed FGMs of SS-316L/CS with improved mechanical and enhanced gradation in physical and structural properties can potentially be utilized in the components with load-bearing application.

  16. Properties of passive film formed on 316L/2205 stainless steel by Mott-Schottky theory and constant current polarization method

    Institute of Scientific and Technical Information of China (English)

    CHENG XueQun; LI XiaoGang; DU CuiWei

    2009-01-01

    Semiconductor properties of the passive films formed on 316L and 2205 stainless steel were studied by Electrochemical Impedance Spectroscopy (EIS) in the high-temperature acetic acid.The results showed that the corrosion resistance of 2205 was higher than that of 316L,and the passive films formed on 316L and 2205 stainless steel showed p-type and n-type semiconductor behavior,respectively.Destruction and self-repairing of passive films were studied by using the constant current polarization method.The results showed that for 316L,the self-repairing process would occur when the destruction was lower than the critical extent or it would not do;for 2205,the self-repairing process only happened in a short time when the destruction was in the same extent as 316L.

  17. Hydrophilic property of 316L stainless steel after treatment by atmospheric pressure corona streamer plasma using surface-sensitive analyses

    Energy Technology Data Exchange (ETDEWEB)

    Al-Hamarneh, Ibrahim, E-mail: hamarnehibrahim@yahoo.com [Department of Physics, Faculty of Science, Al-Balqa Applied University, Salt 19117 (Jordan); Pedrow, Patrick [School of Electrical Engineering and Computer Science, Washington State University, Pullman, WA 99164 (United States); Eskhan, Asma; Abu-Lail, Nehal [Gene and Linda Voiland School of Chemical Engineering and Bioengineering, Washington State University, Pullman, WA 99164 (United States)

    2012-10-15

    Highlights: Black-Right-Pointing-Pointer Surface hydrophilic property of surgical-grade 316L stainless steel was enhanced by Ar-O{sub 2} corona streamer plasma treatment. Black-Right-Pointing-Pointer Hydrophilicity, surface morphology, roughness, and chemical composition before and after plasma treatment were evaluated. Black-Right-Pointing-Pointer Contact angle measurements and surface-sensitive analyses techniques, including XPS and AFM, were carried out. Black-Right-Pointing-Pointer Optimum plasma treatment conditions of the SS 316L surface were determined. - Abstract: Surgical-grade 316L stainless steel (SS 316L) had its surface hydrophilic property enhanced by processing in a corona streamer plasma reactor using O{sub 2} gas mixed with Ar at atmospheric pressure. Reactor excitation was 60 Hz ac high-voltage (0-10 kV{sub RMS}) applied to a multi-needle-to-grounded screen electrode configuration. The treated surface was characterized with a contact angle tester. Surface free energy (SFE) for the treated stainless steel increased measurably compared to the untreated surface. The Ar-O{sub 2} plasma was more effective in enhancing the SFE than Ar-only plasma. Optimum conditions for the plasma treatment system used in this study were obtained. X-ray photoelectron spectroscopy (XPS) characterization of the chemical composition of the treated surfaces confirms the existence of new oxygen-containing functional groups contributing to the change in the hydrophilic nature of the surface. These new functional groups were generated by surface reactions caused by reactive oxidation of substrate species. Atomic force microscopy (AFM) images were generated to investigate morphological and roughness changes on the plasma treated surfaces. The aging effect in air after treatment was also studied.

  18. Crack growth behavior of warm-rolled 316L austenitic stainless steel in high-temperature hydrogenated water

    Science.gov (United States)

    Choi, Kyoung Joon; Yoo, Seung Chang; Jin, Hyung-Ha; Kwon, Junhyun; Choi, Min-Jae; Hwang, Seong Sik; Kim, Ji Hyun

    2016-08-01

    To investigate the effects of warm rolling on the crack growth of 316L austenitic stainless steel, the crack growth rate was measured and the oxide structure was characterized in high-temperature hydrogenated water. The warm-rolled specimens showed a higher crack growth rate compared to the as-received specimens because the slip bands and dislocations produced during warm rolling served as paths for corrosion and cracking. The crack growth rate increased with the dissolved hydrogen concentration. This may be attributed to the decrease in performance and stability of the protective oxide layer formed on the surface of stainless steel in high-temperature water.

  19. Microstructural, Micro-hardness and Sensitization Evaluation in HAZ of Type 316L Stainless Steel Joint with Narrow Gap Welds

    Energy Technology Data Exchange (ETDEWEB)

    Islam, Faisal Shafiqul; Jang, Changheui [KAIST, Daejeon (Korea, Republic of); Kang, Shi Chull [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2015-10-15

    From Micro-hardness measurement HAZ zone was found approximately 1-1.5 mm in NGW and DL-EPR test confirmed that 316L NGW HAZ was not susceptible to sensitization as DOS <1% according to sensitization criteria based on reference. In nuclear power plants 316L stainless steels are commonly used material for their metallurgical stability, high corrosion resistance, and good creep and ductility properties at elevated temperatures. Welding zone considered as the weakest and failure initiation source of the components. For safety and economy of nuclear power plants accurate and dependable structural integrity assessment of main components like pressure vessels and piping are need as it joined by different welding process. In similar and dissimilar metal weld it has been observed that weld microstructure cause the variation of mechanical properties through the thickness direction. In the Heat Affected Zone (HAZ) relative to the fusion line face a unique thermal experience during welding.

  20. Process-Structure-Property Relationships for 316L Stainless Steel Fabricated by Additive Manufacturing and Its Implication for Component Engineering

    Science.gov (United States)

    Yang, Nancy; Yee, J.; Zheng, B.; Gaiser, K.; Reynolds, T.; Clemon, L.; Lu, W. Y.; Schoenung, J. M.; Lavernia, E. J.

    2016-12-01

    We investigate the process-structure-property relationships for 316L stainless steel prototyping utilizing 3-D laser engineered net shaping (LENS), a commercial direct energy deposition additive manufacturing process. The study concluded that the resultant physical metallurgy of 3-D LENS 316L prototypes is dictated by the interactive metallurgical reactions, during instantaneous powder feeding/melting, molten metal flow and liquid metal solidification. The study also showed 3-D LENS manufacturing is capable of building high strength and ductile 316L prototypes due to its fine cellular spacing from fast solidification cooling, and the well-fused epitaxial interfaces at metal flow trails and interpass boundaries. However, without further LENS process control and optimization, the deposits are vulnerable to localized hardness variation attributed to heterogeneous microstructure, i.e., the interpass heat-affected zone (HAZ) from repetitive thermal heating during successive layer depositions. Most significantly, the current deposits exhibit anisotropic tensile behavior, i.e., lower strain and/or premature interpass delamination parallel to build direction (axial). This anisotropic behavior is attributed to the presence of interpass HAZ, which coexists with flying feedstock inclusions and porosity from incomplete molten metal fusion. The current observations and findings contribute to the scientific basis for future process control and optimization necessary for material property control and defect mitigation.

  1. Effect of ascorbic acid on the pitting resistance of 316L stainless steel in synthetic tap water

    Science.gov (United States)

    Hong, Min-Sung; Kim, Seon-Hong; Im, Shin-Young; Kim, Jung-Gu

    2016-07-01

    This study examined the effect of L-ascorbic acid (A.A) concentration on the pitting corrosion properties of 316L stainless steel (316L STS) of heat exchanger in synthetic tap water containing 400 ppm of Cl- ion. The pitting corrosion of 316L STS can be effectively inhibited by the 10-4 M of A.A concentration. In this condition, the adsorption of A.A reinforced the passive film of steel by blocking the Cl- ions at the active site. However, the passive film was deteriorated and severe pitting corrosion occurred above the 10-4 M of A.A concentration. Above the 10-4 M of A.A concentration, A.A generates soluble chelate rather than absorbs on the steel surface and it causes passive film deterioration and severe pitting corrosion. The critical ratio, which is a critical ratio of surface coverage of aggressive to inhibitive ion necessary to initiate localized corrosion, calculated 2.93 up to the 10-4 M. It has approximately 2.93:1 ratio of the coverage of local Cl- ions to A.A. Above the critical ratio, the pitting corrosion will occur with degradation of the passive film. On the other hands, above the 10-4 M A.A concentration caused a negative effect because the heat energy for adsorption is increased.

  2. Mechanical properties of type 316L stainless steel welded joint for ITER vacuum vessel (1). Experiment of unirradiated welded joint

    Energy Technology Data Exchange (ETDEWEB)

    Saito, Shigeru; Fukaya, Kiyoshi [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Ishiyama, Shintaro [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment; Takahashi, Hiroyuki; Koizumi, Kouichi [Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan). Naka Fusion Research Establishment

    2001-01-01

    In design activity of ITER, the vacuum vessel (VV) is ranked as one of the most important components in core reactor from the view point of first barrier to tritium release from the reactor. The VV of ITER is designed as double walled structure so that some parts of them are not qualified in the conventional design standards. So it is necessary to prepare the new design standards to be applied them. JAERI has executed the preparation activity of the new design standards and the technical data to support them. In this study, the results of metallographic observation and mechanical properties of unirradiated type 316L stainless steel welded joint were reported. (author)

  3. Effective Duration of Gas Nitriding Process on AISI 316L for the Formation of a Desired Thickness of Surface Nitrided Layer

    Directory of Open Access Journals (Sweden)

    Mahmoud Hassan R. S.

    2014-07-01

    Full Text Available High temperature gas nitriding performed on AISI 316L at the temperature of 1200°C. The microstructure of treated AISI 316L samples were observed to identify the formation of the microstructure of nitrided surface layer. The grain size of austenite tends to be enlarged when the nitriding time increases, but the austenite single phase structure is maintained even after the long-time solution nitriding. Using microhardness testing, the hardness values drop to the center of the samples. The increase in surface hardness is due to the high nitrogen concentration at or near the surface. At 245HV, the graph of the effective duration of nitriding process was plotted to achieve the maximum depth of nitrogen diffuse under the surface. Using Sigma Plot software best fit lines of the experimental result found and plotted to find out effective duration of nitriding equation as Y=1.9491(1-0.7947x, where Y is the thickness of nitrided layer below the surface and X is duration of nitriding process. Based on this equation, the duration of gas nitriding process can be estimated to produce desired thickness of nitrided layer.

  4. Additive manufacturing of 316L stainless steel by electron beam melting for nuclear fusion applications

    Science.gov (United States)

    Zhong, Yuan; Rännar, Lars-Erik; Liu, Leifeng; Koptyug, Andrey; Wikman, Stefan; Olsen, Jon; Cui, Daqing; Shen, Zhijian

    2017-04-01

    A feasibility study was performed to fabricate ITER In-Vessel components by one of the metal additive manufacturing methods, Electron Beam Melting® (EBM®). Solid specimens of SS316L with 99.8% relative density were prepared from gas atomized precursor powder granules. After the EBM® process the phase remains as austenite and the composition has practically not been changed. The RCC-MR code used for nuclear pressure vessels provides guidelines for this study and tensile tests and Charpy-V tests were carried out at 22 °C (RT) and 250 °C (ET). This work provides the first set of mechanical and microstructure data of EBM® SS316L for nuclear fusion applications. The mechanical testing shows that the yield strength, ductility and toughness are well above the acceptance criteria and only the ultimate tensile strength of EBM® SS316L is below the RCC-MR code. Microstructure characterizations reveal the presence of hierarchical structures consisting of solidified melt pools, columnar grains and irregular shaped sub-grains. Lots of precipitates enriched in Cr and Mo are observed at columnar grain boundaries while no sign of element segregation is shown at the sub-grain boundaries. Such a unique microstructure forms during a non-equilibrium process, comprising rapid solidification and a gradient 'annealing' process due to anisotropic thermal flow of accumulated heat inside the powder granule matrix. Relations between process parameters, specimen geometry (total building time) and sub-grain structure are discussed. Defects are formed mainly due to the large layer thickness (100 μm) which generates insufficient bonding between a few of the adjacently formed melt pools during the process. Further studies should focus on adjusting layer thickness to improve the strength of EBM® SS316L and optimizing total building time.

  5. Investigation into the joining of MoSi{sub 2} to 316L stainless steel

    Energy Technology Data Exchange (ETDEWEB)

    Vaidya, R.U.; Bartlett, A.H.; Conzone, S.D.; Butt, D.P.

    1996-10-01

    Partial transient liquid phase joining and low temperature brazing were applied in joining MoSi{sub 2} to 316L ss. Exploratory studies were carried out on various interlayer materials. Mechanical, physical, and chemical compatibilities between various interlayers, brazing material, and substrate materials were investigated. Effect of thermal expansion mismatch between various components of the joint on the overall joint integrity was also studied. Preliminary findings are outlined.

  6. The effect of hydrogen peroxide on uranium oxide films on 316L stainless steel

    Energy Technology Data Exchange (ETDEWEB)

    Wilbraham, Richard J., E-mail: r.wilbraham@lancaster.ac.uk [The Lloyd’s Register Foundation Centre for Nuclear Engineering, Engineering Department, Lancaster University, Bailrigg, Lancashire LA1 4YR (United Kingdom); Boxall, Colin, E-mail: c.boxall@lancaster.ac.uk [The Lloyd’s Register Foundation Centre for Nuclear Engineering, Engineering Department, Lancaster University, Bailrigg, Lancashire LA1 4YR (United Kingdom); Goddard, David T., E-mail: dave.t.goddard@nnl.co.uk [National Nuclear Laboratory, Preston Laboratory, Springfields, Preston, Lancashire PR4 0XJ (United Kingdom); Taylor, Robin J., E-mail: robin.j.taylor@nnl.co.uk [National Nuclear Laboratory, Central Laboratory, Seascale, Cumbria CA20 1PG (United Kingdom); Woodbury, Simon E., E-mail: simon.woodbury@nnl.co.uk [National Nuclear Laboratory, Central Laboratory, Seascale, Cumbria CA20 1PG (United Kingdom)

    2015-09-15

    Highlights: • The first report of the presence of both UO{sub 2} and polymeric UO{sub 2}{sup 2+} in the same electrodeposited U oxide sample. • The action of H{sub 2}O{sub 2} on electrodeposited U oxides is described using corrosion based concepts. • Electrodeposited U oxide freely dissolves at hydrogen peroxide concentrations <100 μmol dm{sup −3}. • At [H{sub 2}O{sub 2}] > 0.1 mmol dm{sup −3} dissolution is inhibited by formation of a studtite passivation layer. • At [H{sub 2}O{sub 2}] ⩾ 1 mol dm{sup −3} studtite formation competes with uranyl–peroxide complex formation. - Abstract: For the first time the effect of hydrogen peroxide on the dissolution of electrodeposited uranium oxide films on 316L stainless steel planchets (acting as simulant uranium-contaminated metal surfaces) has been studied. Analysis of the H{sub 2}O{sub 2}-mediated film dissolution processes via open circuit potentiometry, alpha counting and SEM/EDX imaging has shown that in near-neutral solutions of pH 6.1 and at [H{sub 2}O{sub 2}] ⩽ 100 μmol dm{sup −3} the electrodeposited uranium oxide layer is freely dissolving, the associated rate of film dissolution being significantly increased over leaching of similar films in pH 6.1 peroxide-free water. At H{sub 2}O{sub 2} concentrations between 1 mmol dm{sup −3} and 0.1 mol dm{sup −3}, formation of an insoluble studtite product layer occurs at the surface of the uranium oxide film. In analogy to corrosion processes on common metal substrates such as steel, the studtite layer effectively passivates the underlying uranium oxide layer against subsequent dissolution. Finally, at [H{sub 2}O{sub 2}] > 0.1 mol dm{sup −3} the uranium oxide film, again in analogy to common corrosion processes, behaves as if in a transpassive state and begins to dissolve. This transition from passive to transpassive behaviour in the effect of peroxide concentration on UO{sub 2} films has not hitherto been observed or explored, either in terms

  7. Microstructure of Au-ion irradiated 316L and FeNiCr austenitic stainless steels

    Science.gov (United States)

    Jublot-Leclerc, S.; Li, X.; Legras, L.; Lescoat, M.-L.; Fortuna, F.; Gentils, A.

    2016-11-01

    Thin foils of 316L were irradiated in situ in a Transmission Electron Microscope with 4 MeV Au ions at 450 °C and 550 °C. Similar irradiations were performed at 450 °C in FeNiCr. The void and dislocation microstructure of 316L is found to depend strongly on temperature. At 450 °C, a dense network of dislocation lines is observed in situ to grow from black dot defects by absorption of other black dots and interstitial clusters whilst no Frank loops are detected. At 550 °C, no such network is observed but large Frank loops and perfect loops whose sudden appearance is concomitant with a strong increase in void density as a result of a strong coupling between voids and dislocations. Moreover, differences in both alloys microstructure show the major role played by the minor constituents of 316L, increasing the stacking fault formation energy, and possibly leading to significant differences in swelling behaviour.

  8. Comparative study of mechanical properties of 316L stainless steel between traditional production methods and selective laser melting

    Science.gov (United States)

    Lackey, Alton Dale

    Additive manufacturing, also known as 3D printing, is a technology which has recently seen expanding use, as well as expansion of the materials and methods able to be used. This thesis looks at the comparison of mechanical properties of 316L stainless steel manufactured by both traditional methods and selective laser melting found by tensile testing. The traditional method used here involved cold rolled 316L steel being machined to the desired part geometry. Selective laser melting used additive manufacturing to produce the parts from powdered 316L stainless steel, doing so in two different build orientations, flat and on edge with regards to the build plate. Solid test specimens, as well as specimens containing a circular stress concentration in the center of the parts, were manufactured and tensile tested. The tensile tests of the specimens were used to find the mechanical properties of the material; including yield strength, ultimate tensile strength (UTS), and Young's modulus of elasticity; where statistical analyses were performed to determine if the different manufacturing processes caused significant differences in the mechanical properties of the material. These analysis consisting of f-tests, to test for variance, and t-test, testing for significant difference of means. Through this study it was found that there were statistically significant differences existing between the mechanical properties of selective laser melting, and its orientations, and cold roll forming of production of parts. Even with a statistical difference, it was found that the results were reasonably close between flat oriented SLM parts and purchased parts. So it can be concluded that, with regards to strength, SLM methods produce parts similar to traditional production methods.

  9. Mechanical properties of similar and dissimilar weldments of RAFMS and AISI 316L (N) SS prepared by electron beam welding process

    Energy Technology Data Exchange (ETDEWEB)

    Albert, S.K., E-mail: shaju@igcar.gov.in [Indira Gandhi Center for Atomic Research, Kalpakkam 603 102 (India); Das, C.R. [Indira Gandhi Center for Atomic Research, Kalpakkam 603 102 (India); Sam, Shiju [Institute of Plasma Research, Gandhi Nagar (India); Mastanaiah, P.; Patel, M. [Defence Research and Development Laboratory, Hyderabad (India); Bhaduri, A.K.; Jayakumar, T. [Indira Gandhi Center for Atomic Research, Kalpakkam 603 102 (India); Murthy, C.V.S. [Defence Research and Development Laboratory, Hyderabad (India); Kumar, Rajendra [Institute of Plasma Research, Gandhi Nagar (India)

    2014-10-15

    Highlights: • Increase of W content in RAFM steel can result in retention of delta ferrite in the EB weld of the steel. • Presence of delta ferrite seems to affect the ductile brittle transition temperature of the weld metal. • There is improper mixing of the two base metals in the fusion zone dissimilar welds of RAFM steel and austenitic stainless steel made by EB welding. - Abstract: Effect of weld metal composition on microstructure and toughness of weld metal is studied in this paper. Weld joints of reduced activation ferritic/martensitic (RAFM) steel containing 1.0 and 1.4 wt.% W were prepared using electron beam welding (EBW) process. Dissimilar weld joints between 1.0 wt.% W RAFM steel and AISI 316L (N) SS were also prepared using EBW process. The effect of post weld heat treatment (PWHT) temperatures on microstructure and mechanical properties was also studied. Microstructural observation reveals delta–ferrite in 1.4 wt.% W containing weld metal, which is absent in 1.0 wt.% W weld metal. In the case of the dissimilar weld metal, microstructure shows presence of lath martensite and retained austenite. Austenite was stable even after PWHT and its presence is attributed to high nickel (5–6 wt.%) content in the dissimilar weld metal. Hardness of RAFM steel weld metal was found to be 270–290 VHN after PWHT at 750 °C for 2 h. Impact toughness of both 1.0 and 1.4 wt.% W RAFM steel is high (>250 J) at ambient temperature. However, after PWHT, variation of toughness with temperature is more drastic for 1.4 wt.% W RAFM steel weld metal than the other. As a result, ductile brittle transition temperature (DBTT) for the 1.4 wt.% steel weld metal is close to 0 °C while that of the 1.0 wt.% W steel is close to that of the base metal (∼−80 °C)

  10. Intergranular Corrosion of 316L Stainless Steel by Aging and UNSM (Ultrasonic Nano-crystal Surface Modification) treatment

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J. H.; Kim, Y. S. [School of Materials Science and Engineering, Andong National University, Andong (Korea, Republic of)

    2015-12-15

    Austenitic stainless steels have been widely used in many engineering fields because of their high corrosion resistance and good mechanical properties. However, welding or aging treatment may induce intergranular corrosion, stress corrosion cracking, pitting, etc. Since these types of corrosion are closely related to the formation of chromium carbide in grain boundaries, the alloys are controlled using methods such as lowering the carbon content, solution heat treatment, alloying of stabilization elements, and grain boundary engineering. This work focused on the effects of aging and UNSM (Ultrasonic Nano-crystal Surface Modification) on the intergranular corrosion of commercial 316L stainless steel and the results are discussed on the basis of the sensitization by chromium carbide formation and carbon segregation, residual stress, grain refinement, and grain boundary engineering.

  11. Plasma surface oxidation of 316L stainless steel for improving adhesion strength of silicone rubber coating to metal substrate

    Energy Technology Data Exchange (ETDEWEB)

    Latifi, Afrooz, E-mail: afroozlatifi@yahoo.com [Department of Biomaterials, Biomedical Engineering Faculty, Science and Research Branch, Islamic Azad University, Tehran (Iran, Islamic Republic of); Imani, Mohammad [Novel Drug Delivery Systems Dept., Iran Polymer and Petrochemical Institute, P.O. Box 14965/115, Tehran (Iran, Islamic Republic of); Khorasani, Mohammad Taghi [Biomaterials Dept., Iran Polymer and Petrochemical Institute, P.O. Box 14965/159, Tehran (Iran, Islamic Republic of); Daliri Joupari, Morteza [Animal and Marine Biotechnology Dept., National Institute of Genetic Engineering and Biotechnology, P.O. Box 14965/161, Tehran (Iran, Islamic Republic of)

    2014-11-30

    Highlights: • Stainless steel 316L was surface modified by plasma surface oxidation (PSO) and silicone rubber (SR) coating. • On the PSO substrates, concentration of oxide species was increased ca. 2.5 times comparing to non-PSO substrates. • The surface wettability was improved to 12.5°, in terms of water contact angle, after PSO. • Adhesion strength of SR coating on the PSO substrates was improved by more than two times comparing to non-PSO ones. • After pull-off test, the fractured area patterns for SR coating were dependent on the type of surface modifications received. - Abstract: Stainless steel 316L is one of the most widely used materials for fabricating of biomedical devices hence, improving its surface properties is still of great interest and challenging in biomaterial sciences. Plasma oxidation, in comparison to the conventional chemical or mechanical methods, is one of the most efficient methods recently used for surface treatment of biomaterials. Here, stainless steel specimens were surface oxidized by radio-frequency plasma irradiation operating at 34 MHz under pure oxygen atmosphere. Surface chemical composition of the samples was significantly changed after plasma oxidation by appearance of the chromium and iron oxides on the plasma-oxidized surface. A wettable surface, possessing high surface energy (83.19 mN m{sup −1}), was observed after plasma oxidation. Upon completion of the surface modification process, silicone rubber was spray coated on the plasma-treated stainless steel surface. Morphology of the silicone rubber coating was investigated by scanning electron microscopy (SEM). A uniform coating was formed on the oxidized surface with no delamination at polymer–metal interface. Pull-off tests showed the lowest adhesion strength of coating to substrate (0.12 MPa) for untreated specimens and the highest (0.89 MPa) for plasma-oxidized ones.

  12. Effect of Copper and Bronze Addition on Corrosion Resistance of Alloyed 316L Stainless Steel Cladded on Plain Carbon Steel by Powder Metallurgy

    Institute of Scientific and Technical Information of China (English)

    Wenjue CHEN; Yueying WU; Jianian SHEN

    2004-01-01

    A sandwich structure with cladding alloyed 316L stainless steel on plain carbon steel was prepared by means of powder metallurgy (PM) processing. Electrolytic Cu and prealloyed bronze (95Cu wt pct, 5Sn wt pct) were added in different contents up to 15% into the surface cladded 316L layers and the effect of alloying concentrations on the corrosion resistance of the 316L cladding layers was studied. The corrosion performances of the cladding samples were studied by immersion tests and potentio-dynamic anodic polarization tests in H2SO4 and FeCl3 solutions. Both 316L and alloyed 316L surface layers with 1.0 mm depth produced by PM cladding had an effect to improve corrosion resistance in H2SO4 and FeCl3 solutions. Small Cu and bronze addition (4%) had a positive effect in H2SO4 and FeCl3 solutions. 4% Cu alloyed 316L surface layer produced by PM cladding showed similar anodic polarization behaviour to the 316L cladding layer in H2SO4 and FeCl3 solutions.

  13. Influence of oversized elements (Hf, Zr, Ti and Nb) on the thermal stability of vacancies in type 316L stainless steels

    Energy Technology Data Exchange (ETDEWEB)

    Yabuuchi, A., E-mail: yabuuchi.atsushi@21c.osakafu-u.ac.jp [Advanced Science Research Center, Japan Atomic Energy Agency, 1233 Watanuki, Takasaki, Gunma 370-1292 (Japan); Maekawa, M.; Kawasuso, A. [Advanced Science Research Center, Japan Atomic Energy Agency, 1233 Watanuki, Takasaki, Gunma 370-1292 (Japan)

    2012-11-15

    To reveal the influence of oversized elements on the thermal stability of vacancies in type 316L stainless steels, vacancy recovery processes were investigated by means of positron annihilation spectroscopy. Although vacancies in additive-free 316L stainless steels were mobile at 300 Degree-Sign C, which is a typical nuclear reactor operating temperature, vacancies in oversized elements doped 316L were stable up to 300-350 Degree-Sign C. This result indicates that oversized elements stabilize vacancies in stainless steels. Stability of vacancies inhibits the radiation-induced grain boundary segregation and may also lead to suppression of high-temperature water stress corrosion cracking that is observed in nuclear materials.

  14. State on AISI 304 Stainless Steel

    Directory of Open Access Journals (Sweden)

    A. Fattah-alhosseini

    2011-01-01

    Full Text Available The passivity and protective nature of the passive films are essentially related to ionic and electronic transport processes, which are controlled by the optical and electronic properties of passive films. In this study, the electrochemical behavior of passive films anodically formed on AISI 304 stainless steel in sulfuric acid solution has been examined using electrochemical impedance spectroscopy. AISI 304 in sulphuric acid solution is characterized by high interfacial impedance, thereby illustrating its high corrosion resistance. Results showed that the interfacial impedance and the polarization resistance (pol initially increase with applied potential, within the low potential passive. However, at a sufficiently high potential passive (>0.4 V, the interfacial impedance and the polarization resistance decrease with increasing potential. An electrical equivalent circuit based on the impedance analysis, which describes the behavior of the passive film on stainless steel more satisfactorily than the proposed models, is presented.

  15. 316L stainless steel silver plated plate vacuum heat treatment technology%316L不锈钢镀银板的真空热处理工艺

    Institute of Scientific and Technical Information of China (English)

    王红涛

    2012-01-01

      本文分别通过探讨真空环境下热处理温度和热处理时间对316L不锈钢镀银板性能的影响,从而确定316L不锈钢镀银板的最佳真空热处理工艺。%  This paper through the study of the vacuum heat treatment temperature on properties of 316L stainless steel silver plate, so as to determine the optimal 316L stainless steel silver plated vacuum heat treatment technology.

  16. Investigation into Effects of Scanning Speed on in Vitro Biocompatibility of Selective Laser Melted 316L Stainless Steel Parts

    Directory of Open Access Journals (Sweden)

    Shang Yitong

    2017-01-01

    Full Text Available In recent years, selective laser melting (SLM has gained an important place in fabrication due to their strong individualization which cannot be manufactured using conventional processes such as casting or forging. By proper control of the SLM processing parameters, characteristics of the alloy can be optimized. In the present work, 316L stainless steel (SS, as a widely used biomedical material, is investigated in terms of the effects of scanning speed on in vitro biocompatibility during SLM process. Cytotoxicity assay is adopted to assess the in vitro biocompatibility. The results show the scanning speed strongly affects the in vitro biocompatibility of 316L SS parts and with prolongs of incubation time, the cytotoxicity increase and the in vitro biocompatibility gets worse. The optimal parameters are determined as follows: scanning speed of 900 mm/s, laser power of 195 W, hatch spacing of 0.09 mm and layer thickness of 0.02 mm. The processing parameters lead to the change of surface morphology and microstructures of samples, which can affect the amount of toxic ions release, such as Cr, Mo and Co, that can increase risks to patient health and reduce the biocompatibility.

  17. Effect of copper addition on mechanical properties, corrosion resistance and antibacterial property of 316L stainless steel.

    Science.gov (United States)

    Xi, Tong; Shahzad, M Babar; Xu, Dake; Sun, Ziqing; Zhao, Jinlong; Yang, Chunguang; Qi, Min; Yang, Ke

    2017-02-01

    The effects of addition of different Cu content (0, 2.5 and 3.5wt%) on mechanical properties, corrosion resistance and antibacterial performance of 316L austenitic stainless steel (SS) after solution and aging treatment were investigated by mechanical test, transmission electron microscope (TEM), X-ray diffraction (XRD), electrochemical corrosion, X-ray photoelectron spectroscopy (XPS) and antibacterial test. The results showed that the Cu addition and heat treatment had no obvious influence on the microstructure with complete austenite features. The yield strength (YS) after solution treatment was almost similar, whereas the aging treatment obviously increased the YS due to formation of tiny Cu-rich precipitates. The pitting and protective potential of the solution treated Cu-bearing 316L SS in 0.9wt% NaCl solution increased with increasing Cu content, while gradually declined after aging, owing to the high density Cu-rich precipitation. The antibacterial test proved that higher Cu content and aging were two compulsory processes to exert good antibacterial performance. The XPS results further indicated that aging enhanced the Cu enrichment in passive film, which could effectively stimulate the Cu ions release from the surface of passive film.

  18. Surface modification of 316L stainless steel with magnetron sputtered TiN/VN nanoscale multilayers for bio implant applications.

    Science.gov (United States)

    Subramanian, B; Ananthakumar, R; Kobayashi, Akira; Jayachandran, M

    2012-02-01

    Nanoscale multilayered TiN/VN coatings were developed by reactive dc magnetron sputtering on 316L stainless steel substrates. The coatings showed a polycrystalline cubic structure with (111) preferential growth. XPS analysis indicated the presence of peaks corresponding to Ti2p, V2p, N1s, O1s, and C1s. Raman spectra exhibited the characteristic peaks in the acoustic range of 160-320 cm(-1) and in the optic range between 480 and 695 cm(-1). Columnar structure of the coatings was observed from TEM analysis. The number of adherent platelets on the surface of the TiN/VN multilayer, VN, TiN single layer coating exhibit fewer aggregation and pseudopodium than on substrates. The wear resistance of the multilayer coatings increases obviously as a result of their high hardness. Tafel plots in simulated bodily fluid showed lower corrosion rate for the TiN/VN nanoscale multilayer coatings compared to single layer and bare 316L SS substrate.

  19. A simulation study on the multi-pass rolling bond of 316L/Q345R stainless clad plate

    Directory of Open Access Journals (Sweden)

    Qin Qin

    2015-07-01

    Full Text Available This article describes an investigation into interface bonding research of 316L/Q345R stainless clad plate. A three-dimensional thermal–elastic–plastic model has been established using finite element analysis to model the multi-pass hot rolling process. Results of the model have been compared with those obtained from a rolling experiment of stainless clad plate. The comparisons of temperature and profile of the rolled stainless clad plate have indicated a satisfactory accuracy of finite element analysis simulation. Effects on interface bonding by different parameters including pre-heating temperature, multi-pass thickness reduction rules, rolling speed, covering rate, and different assemble patterns were analyzed systematically. The results show that higher temperature and larger thickness reduction are beneficial to achieve the bonding in vacuum hot rolling process. The critical reduction in the bond at the temperature of 1200 °C is 28%, and the critical thickness reduction reduces by about 2% when the temperature increases by 50 °C during the range from 1000 °C to 1250 °C. And the relationship between the minimum pass number and thickness reduction has been suggested. The results also indicate that large covering rate in the assemble pattern of outer soft and inner hard is beneficial to achieve the bond of stainless clad plate.

  20. Effects of dissolved oxygen on electrochemical and semiconductor properties of 316L stainless steel

    Energy Technology Data Exchange (ETDEWEB)

    Feng Zhicao [Corrosion and Protection Center, University of Science and Technology Beijing, Beijing 100083 (China); Cheng Xuequn, E-mail: chxq2000@hotmail.co [Corrosion and Protection Center, University of Science and Technology Beijing, Beijing 100083 (China); Dong Chaofang; Xu Lin [Corrosion and Protection Center, University of Science and Technology Beijing, Beijing 100083 (China); Li Xiaogang, E-mail: lixiaogang99@263.ne [Corrosion and Protection Center, University of Science and Technology Beijing, Beijing 100083 (China)

    2010-12-31

    The effects of dissolved oxygen on the electrochemical behavior and semiconductor properties of passive film formed on 316L SS in three solutions with different dissolved oxygen were studied by using polarization curve, Mott-Schottky analysis and the point defect model (PDM). The results show that higher dissolved oxygen accelerates both anodic and cathodic process. Based on Mott-Schottky analysis and PDM, the key parameters for passive film, donor density N{sub d}, flat-band potential E{sub fb} and diffusivity of defects D{sub 0} were calculated. The results display that N{sub d}(1-7 x 10{sup 27}m{sup -3}) and D{sub 0}(1-18 x 10{sup -16}cm{sup 2}/s) increase and E{sub fb} value reduces with the dissolved oxygen in solution.

  1. Effect of irradiation on the steels 316L/LN type to 12 dpa at 400 °C

    Science.gov (United States)

    Bulanova, T.; Fedoseev, A.; Kalinin, G.; Rodchenkov, B.; Shamardin, V.

    2004-08-01

    The 316L type stainless steel is widely used as a structural material for the fission reactors internal structures (core, core supports, etc.) and for experimental irradiation facilities. The 316L(N)-IG type steel is proposed as a main structural material for the ITER reactor (first wall, blanket, vacuum vessel, cooling pipe lines). It is obvious that different steel grades should exhibit different reaction to neutron irradiation. The main objective of this work was to study of irradiation behaviour of three different commercial steels: AISI 316LN, AISI 316L (US grades) and 02X17H14M2 (Russian steel grade that is similar to 316L). Irradiation effect on the three commercial steels of 316L family to ˜12 dpa at the temperature ˜370-400 °C on the tensile properties, microstructure, swelling and susceptibility to SCC are described in the paper.

  2. Effect of irradiation on the steels 316L/LN type to 12 dpa at 400 deg. C

    Energy Technology Data Exchange (ETDEWEB)

    Bulanova, T. E-mail: fae@niiar.rukalinig@nikiet.ru; Fedoseev, A.; Kalinin, G.; Rodchenkov, B.; Shamardin, V

    2004-08-01

    The 316L type stainless steel is widely used as a structural material for the fission reactors internal structures (core, core supports, etc.) and for experimental irradiation facilities. The 316L(N)-IG type steel is proposed as a main structural material for the ITER reactor (first wall, blanket, vacuum vessel, cooling pipe lines). It is obvious that different steel grades should exhibit different reaction to neutron irradiation. The main objective of this work was to study of irradiation behaviour of three different commercial steels: AISI 316LN, AISI 316L (US grades) and 02X17H14M2 (Russian steel grade that is similar to 316L). Irradiation effect on the three commercial steels of 316L family to {approx}12 dpa at the temperature {approx}370-400 deg. C on the tensile properties, microstructure, swelling and susceptibility to SCC are described in the paper.

  3. Performance Optimization of Cold Rolled Type 316L Stainless Steel by Sand Blasting and Surface Linishing Treatment

    Science.gov (United States)

    Krawczyk, B.; Heine, B.; Engelberg, D. L.

    2016-03-01

    Sand blasting followed by a surface linishing treatment was applied to optimize the near-surface microstructure of cold rolled type 316L stainless steel. The introduction of cold rolling led to the formation of α-martensite. Specimens with large thickness reductions (40, 53%) were more susceptible to localized corrosion. The application of sand blasting produced a near-surface deformation layer containing compressive residual stresses with significantly increased surface roughness, resulting in reduced corrosion resistance. The most resistant microstructure was obtained with the application of a final linishing treatment after sand blasting. This treatment produced microstructures with compressive near-surface residual stresses, reduced surface roughness, and increased resistance to localized corrosion.

  4. Laser surface alloying of 316L stainless steel coated with a bioactive hydroxyapatite-titanium oxide composite.

    Science.gov (United States)

    Ghaith, El-Sayed; Hodgson, Simon; Sharp, Martin

    2015-02-01

    Laser surface alloying is a powerful technique for improving the mechanical and chemical properties of engineering components. In this study, laser surface irradiation process employed in the surface modification off 316L stainless steel substrate using hydroxyapatite-titanium oxide to provide a composite ceramic layer for the suitability of applying this technology to improve the biocompatibility of medical alloys and implants. Fusion of the metal surface incorporating hydroxyapatite-titania ceramic particles using a 30 W Nd:YAG laser at different laser powers, 40, 50 and 70% power and a scan speed of 40 mm s(-1) was observed to adopt the optimum condition of ceramic deposition. Coatings were evaluated in terms of microstructure, surface morphology, composition biocompatibility using XRD, ATR-FTIR, SEM and EDS. Evaluation of the in vitro bioactivity by soaking the treated metal in SBF for 10 days showed the deposition of biomimetic apatite.

  5. Ti-WC nanocrystalline coating formed by surface mechanical attrition treatment process on 316L stainless steel.

    Science.gov (United States)

    Aliofkhazraei, M; Rouhaghdam, A Sabour; Ghobadi, E

    2011-10-01

    Nanocrystalline coatings were performed on the surface of 316L stainless steel plates mechanically with a mixture of Ti and WC powders under vacuum conditions. The targets were replaced in the end of the high energy milling rig, while Ti-WC mixture was milled as usual. It is shown that the coatings are nanocrystalline in nature with narrow distribution of average size of nanocrystallites. X-ray diffraction and scanning electron microscopy (with energy-dispersive spectrometer) revealed that the top layer of the coatings is uniform. Microhardness, roughness and primary corrosion tests (tafel tests) proved enhancement of coated samples with respect to raw materials. Transmission electron microscope image of deformed surface confirmed surrounding of nanoparticles by dislocation loops after plastic deformation.

  6. Effect of temperature, chloride ions and sulfide ions on the electrochemical properties of 316L stainless steel in simulated cooling water

    Institute of Scientific and Technical Information of China (English)

    Li Jinbo; Zhai Wen; Zheng Maosheng; Zhu Jiewu

    2008-01-01

    The influence of temperature, chloride ions and sulfide ions on the anticorrosion behavior of 316L stainless steel in simulated cooling water was studied by electrochemical impedance spectroscopy and anodic polarization curves. The results show that the film resistance increases with the solution temperature but decreases after 8 days' immersion, which indicates that the film formed at higher temperature has inferior anticorrosion behavior; Chloride ions and sulfide ions have remarkable effects on the electrochemical property of 316L stainless steel in simulated cooling water and the pitting potential declines with the concentration of chloride ions; the passivation current has no obvious effect; the rise of the concentration of sulfide ions obviously increases the passivation current, but the pitting potential changes little, which indicates that the two types of ions may have different effects on destructing passive film of stainless steel. The critical concentration of chloride ions causing anodic potential curve's change in simulated cooling water is 250 mg/L for 316 L stainless. The effect of sulfide ions on the corrosion resistance behavior of stainless steel is increasing the passivation current density Ip. The addition of 6mg/L sulfide ions to the solution makes Ip of 316 L increase by 0.5 times.

  7. Radiative and convective properties of 316L Stainless Steel fabricated using the Laser Engineered Net Shaping process

    Science.gov (United States)

    Knopp, Jonathan

    Temperature evolution of metallic materials during the additive manufacturing process has direct influence in determining the materials microstructure and resultant characteristics. Through the power of Infrared (IR) thermography it is now possible to monitor thermal trends in a build structure, giving the power to adjust building parameters in real time. The IR camera views radiation in the IR wavelengths and determines temperature of an object by the amount of radiation emitted from the object in those wavelengths. Determining the amount of radiation emitted from the material, known as a materials emissivity, can be difficult in that emissivity is affected by both temperature and surface finish. It has been shown that the use of a micro-blackbody cavity can be used as an accurate reference temperature when the sample is held at thermal equilibrium. A micro-blackbody cavity was created in a sample of 316L Stainless Steel after being fabricated during using the Laser Engineered Net Shaping (LENS) process. Holding the sample at thermal equilibrium and using the micro-blackbody cavity as a reference and thermocouple as a second reference emissivity values were able to be obtained. IR thermography was also used to observe the manufacturing of these samples. When observing the IR thermography, patterns in the thermal history of the build were shown to be present as well as distinct cooling rates of the material. This information can be used to find true temperatures of 316L Stainless Steel during the LENS process for better control of desired material properties as well as future work in determining complete energy balance.

  8. The influence of nanostructured features on bacterial adhesion and bone cell functions on severely shot peened 316L stainless steel.

    Science.gov (United States)

    Bagherifard, Sara; Hickey, Daniel J; de Luca, Alba C; Malheiro, Vera N; Markaki, Athina E; Guagliano, Mario; Webster, Thomas J

    2015-12-01

    Substrate grain structure and topography play major roles in mediating cell and bacteria activities. Severe plastic deformation techniques, known as efficient metal-forming and grain refining processes, provide the treated material with novel mechanical properties and can be adopted to modify nanoscale surface characteristics, possibly affecting interactions with the biological environment. This in vitro study evaluates the capability of severe shot peening, based on severe plastic deformation, to modulate the interactions of nanocrystallized metallic biomaterials with cells and bacteria. The treated 316L stainless steel surfaces were first investigated in terms of surface topography, grain size, hardness, wettability and residual stresses. The effects of the induced surface modifications were then separately studied in terms of cell morphology, adhesion and proliferation of primary human osteoblasts (bone forming cells) as well as the adhesion of multiple bacteria strains, specifically Staphylococcus aureus, Staphylococcus epidermidis, Pseudomonas aeruginosa, and ampicillin-resistant Escherichia coli. The results indicated a significant enhancement in surface work hardening and compressive residual stresses, maintenance of osteoblast adhesion and proliferation as well as a remarkable decrease in the adhesion and growth of gram-positive bacteria (S. aureus and S. epidermidis) compared to non-treated and conventionally shot peened samples. Impressively, the decrease in bacteria adhesion and growth was achieved without the use of antibiotics, for which bacteria can develop a resistance towards anyway. By slightly grinding the surface of severe shot peened samples to remove differences in nanoscale surface roughness, the effects of varying substrate grain size were separated from those of varying surface roughness. The expression of vinculin focal adhesions from osteoblasts was found to be singularly and inversely related to grain size, whereas the attachment of gram

  9. Effect of relative humidity in high temperature oxidation of ceria nanoparticles coating on 316L austenitic stainless steel

    Science.gov (United States)

    Giraldez Pizarro, Luis Miguel

    A solution of 20 wt. % colloidal dispersion of Cerium Oxide (CeO2) in 2.5% of acetic acid, was used for depositing a coating film on an austenitic stainless steel 316L. Cerium compounds have been distinguished as potential corrosion inhibitors in coatings over several alloys. The oxidation behavior of the cerium oxide coating on 316L austenitic stainless steel alloy was evaluated in dry and humid environments, the weight changes (W/A) was monitored as a function of time using a custom built Thermogravimetrical Analysis (TGA) instrument at temperatures of 750°C, 800°C and 850°C, and different relative humidity levels (0%, 10% and 20%) respectively. The parabolic oxidation rate and activation energy is calculated experimentally for each relative humidity level. A measurement of the effective diameter size of the ceria nanoparticles was performed using a Light Scattering technique. A characterization of the film morphology and thickness before the oxidation was executed using Atomic Force Microscopy (AFM). Microstructure and chemical composition of the oxidized coated substrates were analyzed using Scanning Electronic Microscopy (SEM) with energy dispersive spectroscopy (EDS). X-Ray Diffractometer (XRD) was used to characterize oxides formed in the surface upon isothermal treatment. A comparison of activation energy values obtained to identify the influence of relative humidity in the oxidation process at high temperature was conducted. Cerium oxides coating may prevent crevice corrosion and increase pitting resistance of 316L relative to the uncoated substrate at high temperatures and different levels of relative humidity acting as a protective oxidation barrier. The calculated parabolic rate constants, kp, at the experimental temperatures tend to increase as a function of humidity levels. The activation energy tends to increase proportionally to higher level of humidity exposures. At 0% relative humidity a value of 319.29 KJ/mol of activation energy is being

  10. Evaluation of weld defects in stainless steel 316L pipe using guided wave

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Joon Hyun [School of Mechanical Engineering, Pusan National University, Busan (Korea, Republic of); Lee, Jin Kyung [Dept. of Mechanical Engineering, Dongeui University, Busan (Korea, Republic of)

    2015-02-15

    Stainless steel is a popular structural materials for liquid-hydrogen storage containers and piping components for transporting high-temperature fluids because of its superior material properties such as high strength and high corrosion resistance at elevated temperatures. In general, tungsten inert gas (TIG) arc welding is used for bonding stainless steel. However, it is often reported that the thermal fatigue cracks or initial defects in stainless steel after welding decreases the reliability of the material. The objective of this paper is to clarify the characteristics of ultrasonic guided wave propagation in relation to a change in the initial crack length in the welding zone of stainless steel. For this purpose, three specimens with different artificial defects of 5 mm, 10 mm, and 20 mm in stainless steel welds were prepared. By considering the thickness of s stainless steel pipe, special attention was given to both the L(0,1) mode and L(0,2) mode in this study. It was clearly found that the L(0,2) mode was more sensitive to defects than the L(0,1) mode. Based on the results of the L(0,1) and L(0,2) mode analyses, the magnitude ratio of the two modes was more effective than studying each mode when evaluating defects near the welded zone of stainless steel because of its linear relationship with the length of the artificial defect.

  11. The electrochemical impedance of polarized 316L stainless steel: structure-property-adsorption correlation.

    Science.gov (United States)

    Gettens, Robert T T; Gilbert, Jeremy L

    2009-07-01

    Electrochemical (EC) impedance and polarization data were synergistically coupled with AFM micrographs providing insight on the polarized alloy-electrolyte interface. Several regions of oxide topography/ impedance characteristic were apparent on a 316L SS surface. A relatively rough surface with apparent EC reaction products was observed below -500 mV. Smooth surfaces were seen from -500 mV to 200 mV. A transition region which displayed the aggregation of particles on the surface was seen from 200 mV to 600 mV. Above 600 mV these particles disappeared revealing a smooth topography. These topographical observations matched closely with the impedance behavior of the system, particularly the capacitance (C), polarization resistance (R(p)) and current density. The presence of pre-adsorbed Fb had a significant impact on C below approximately -500 mV (increased capacitance). The deviation from ideality of the current response as determined by a KWW empirical dielectric decay function showed significant differences between PBS-immersed and pre-adsorbed Fb cases. Earlier, changes in Fb area coverage, height, and eccentricity were observed between voltages lower and higher than 0 mV. The presence of the flat-band potential around -150 mV as well as high cathodic charge-transfer reactions taking place below -100 mV relate to these observations.

  12. Characterization of porous TiO2 surfaces formed on 316L stainless steel by plasma electrolytic oxidation for stent applications

    NARCIS (Netherlands)

    Huan, Z.; Fratila-Apachitei, L.E.; Apachitei, I.; Duszczyk, J.

    2012-01-01

    In this study, a porous oxide layer was formed on the surface of 316L stainless steel (SS) by combining Ti magnetron sputtering and plasma electrolytic oxidation (PEO) with the aim to produce a polymer-free drug carrier for drug eluting stent (DES) applications. The oxidation was performed galvanost

  13. Effect of SUS316L stainless steel surface conditions on the wetting of molten multi-component oxides ceramic

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jin, E-mail: wangjinustb@gmail.com [Graduate School of Life Science and Systems Engineering, Kyushu Institute of Technology, Fukuoka, 808-0196 (Japan); Matsuda, Nozomu [Bar and Wire Product Unit, Nippon steel and Sumitomo Metal Corporation, Fukuoka, 802-8686 (Japan); Shinozaki, Nobuya [Graduate School of Life Science and Systems Engineering, Kyushu Institute of Technology, Fukuoka, 808-0196 (Japan); Miyoshi, Noriko [The Center for Instrumental Analysis, Kyushu Institute of Technology, Fukuoka, 804-8550 (Japan); Shiraishi, Takanobu [Graduate School of Biomedical Sciences, Nagasaki University, Nagasaki, 852-8588 (Japan)

    2015-02-01

    Highlights: • Multi-component oxides had a good wetting on stainless substrates with pretreatments. • Various substrates surface roughness caused the difference of final contact angles. • The wetting rate was slow on polished substrate due to the slow surface oxidation. - Abstract: A study on the effect of SUS316L stainless steel surface conditions on the wetting behavior of molten multi-component oxides ceramic was performed and aimed to contribute to the further understanding of the application of oxides ceramic in penetration treatment of stainless steel coatings and the deposition of stainless steel cermet coatings. The results show that at 1273 K, different surface pre-treatments (polishing and heating) had an important effect on the wetting behavior. The molten multi-component oxides showed good wettability on both stainless steel substrates, however, the wetting process on the polished substrate was significantly slower than that on the heated substrates. The mechanism of the interfacial reactions was discussed based on the microscopic and thermodynamic analysis, the substrates reacted with oxygen generated from the decomposition of the molten multi-component oxides and oxygen contained in the argon atmosphere, and the oxide film caused the molten multi-component oxides ceramic to spread on the substrates surfaces. For the polished substrate, more time was required for the surface oxidation to reach the surface composition of Heated-S, which resulted in relatively slow spreading and wetting rates. Moreover, the variance of the surface roughness drove the final contact angles to slightly different values following the sequence Polished-S > Heated-S.

  14. STUDIES ON WETTABILITY OF STAINLESS STEEL 316L POWDER IN LASER MELTING PROCESS

    Directory of Open Access Journals (Sweden)

    KURIAN ANTONY

    2014-10-01

    Full Text Available Laser sintering is one of the techniques used in additive manufacturing processes. The main objective of the work is to study the effects of process parameters on wetting phenomenon and interfacial energy during laser melting of stainless steel powder. This paper reports wetting of laser melted powder particles and its use for the determination of surface energy of stainless steel powder under laser beam exposure. Process parameters such as laser power, scan speed and beam diameter are considered for study. This study also identifies the process parameters for better wettability which produces smooth surfaces.

  15. Effect of oxygen partial pressure on oxidation performance of iron-aluminide layers on 316L stainless steel

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Hong-guang; Zhan, Qin; Zhao, Wei-wei; Yuan, Xiao-ming [China Institute of Atomic Energy, Beijing (China). Dept. of Reactor Engineering Research and Design

    2009-07-01

    Tritium permeation barriers (TPB) are required in fusion technology in order to reduce the tritium permeation rate through the structural materials such as type 316 stainless steel. Iron-aluminide layers with alumina on top have been selected as the reference materials for TPB. Aluminide were prepared on the 316L (00Cr17Ni14Mo2) stainless steel by a specific aluminizing process and its oxidation behaviors have been studied in CIAE. This paper is focused on the effect of oxygen partial pressure on the characterization of the surface alumina films. Alumina films were formed on the Fe-Al coatings under the oxygen partial pressure below 200Pa, which is mainly composed of Al{sub 2}O{sub 3} with the thickness upto 300nm, and a little CeO{sub 2} and Cr{sub 2}O{sub 3}. It shows the formation of alumina films because of the selective oxidation of the aluminide on the top surface. (orig.)

  16. Effect of thermal treatment on the corrosion resistance of Type 316L stainless steel exposed in supercritical water

    Energy Technology Data Exchange (ETDEWEB)

    Jiao, Y. [Department of Materials Science & Engineering, McMaster University, Hamilton, ON (Canada); Zheng, W. [CanmetMATERIALS, Natural Resources Canada, Hamilton, ON (Canada); Guzonas, D.A. [Canadian Nuclear Laboratories Chalk River Laboratories, ON (Canada); Cook, W.G. [Department of Chemical Engineering, University of New Brunswick, Fredericton, NB (Canada); Kish, J.R., E-mail: kishjr@mcmaster.ca [Department of Materials Science & Engineering, McMaster University, Hamilton, ON (Canada)

    2015-09-15

    There are still unknown aspects about the growth mechanism of oxide scales formed on candidate stainless steel fuel cladding materials during exposure in supercritical water (SCW) under the conditions relevant to the Canadian supercritical water-cooled reactor (SCWR). The tendency for intermetallic precipitates to form within the grains and on grain boundaries during prolonged exposure at high temperatures represents an unknown factor to corrosion resistance, since they tend to bind alloyed Cr. The objective of this study was to better understand the extent to which intermetallic precipitates affects the mode and extent of corrosion in SCW. Type 316L stainless steel, used as a model Fe–Cr–Ni–Mo alloy, was exposed to 25 MPa SCW at 550 °C for 500 h in a static autoclave for this purpose. Mechanically-abraded samples were tested in the mill-annealed (MA) and a thermally-treated (TT) condition. The thermal treatment was conducted at 815 °C for 1000 h to precipitate the carbide (M{sub 23}C{sub 6}), chi (χ), laves (η) and sigma (σ) phases. It was found that although relatively large intermetallic precipitates formed at the scale/alloy interface locally affected the oxide scale formation, their discontinuous formation did not affect the short-term overall apparent corrosion resistance.

  17. MC3T3-E1 cell response to stainless steel 316L with different surface treatments.

    Science.gov (United States)

    Zhang, Hongyu; Han, Jianmin; Sun, Yulong; Huang, Yongling; Zhou, Ming

    2015-11-01

    In the present study, stainless steel 316L samples with polishing, aluminum oxide blasting, and hydroxyapatite (HA) coating were prepared and characterized through a scanning electron microscope (SEM), optical interferometer (surface roughness, Sq), contact angle, surface composition and phase composition analyses. Osteoblast-like MC3T3-E1 cell adhesion on the samples was investigated by cell morphology using a SEM (4h, 1d, 3d, 7d), and cell proliferation was assessed by MTT method at 1d, 3d, and 7d. In addition, adsorption of bovine serum albumin on the samples was evaluated at 1h. The polished sample was smooth (Sq: 1.8nm), and the blasted and HA coated samples were much rougher (Sq: 3.2μm and 7.8μm). Within 1d of incubation, the HA coated samples showed the best cell morphology (e.g., flattened shape and complete spread), but there was no significant difference after 3d and 7d of incubation for all the samples. The absorbance value for the HA coated samples was the highest after 1d and 3d of incubation, indicating better cell viability. However, it reduced to the lowest value at 7d. Protein adsorption on the HA coated samples was the highest at 1h. The results indicate that rough stainless steel surface improves cell adhesion and morphology, and HA coating contributes to superior cell adhesion, but inhibits cell proliferation.

  18. Corrosion of aluminium, stainless steels and AISI 680 nickel alloy in nitrogen-based fuels

    Energy Technology Data Exchange (ETDEWEB)

    Kap, I.; Starostin, M.; Shter, G.E.; Grader, G.S. [Department of Chemical Engineering, Technion-Israel Institute of Technology, Haifa (Israel)

    2012-07-15

    Nitrogen-based compounds can potentially be used as alternative non-carbon or low-carbon fuels. Nevertheless, the corrosion of construction materials at high temperatures and pressures in the presence of such fuel has not been reported yet. This work is focused on the corrosion of AISI Al 6061, 1005 carbon steel (CS), 304, 316L, 310 austenitic stainless steels (SS) and 680 nickel alloy in highly concentrated water solution of ammonium nitrate and urea (ANU). The corrosion at 50 C and ambient pressure and at 350 C and 20 bar was investigated to simulate storage and working conditions. Sodium chloride was added to the fuel (0-5 wt%) to simulate industrial fertilizers and accelerated corrosion environment. Heavy corrosion of CS was observed in ANU solution at 50 C, while Al 6061, 304 and 316L SS showed high resistance both to uniform and pitting corrosion in ANU containing 1% of sodium chloride. Addition of 5% sodium chloride caused pitting of Al 6061 but had no influence on the corrosion of SS. Tests in ANU at 350 C and 20 bar showed pitting on SS 304 and 316L and 680 nickel alloy. The highest corrosion resistance was found for SS 310 due to formation of stable oxide film on its surface. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  19. The effect of Ca/P concentration and temperature of simulated body fluid on the growth of hydroxyapatite coating on alkali-treated 316L stainless steel.

    Science.gov (United States)

    Lin, Feng-Huei; Hsu, Yao-Shan; Lin, Shih-Hsun; Sun, Jui-Sheng

    2002-10-01

    316L-SS is one of the important materials both in orthopaedics and dentistry for bone screw/plate, intra-medullary rod, fixation wire, HIP joint, and knee joint. However, the biocompatibility and bone-bonding ability troubled researches for years. In the study, a simple chemical method was tried so as to establish and induce a bioactive HA layer on the surface of 316L stainless steel. When the metallic substrates treated with 10 M NaOH aqueous solution and subsequently heated at 600 degrees C, a thin sodium chromium oxide layer was formed on the surfaces as the linking layer for HA and 316L-SS. After 316L-SS treated with alkali solution, it would soak into a simulated body fluid with higher concentration of calcium and phosphorous ions to increase the possibility of nucleation of HA. However, the iron oxide and iron chromium oxides were formed on the surface when calcium and phosphorous ions increased. This resulted in loosening the HA layer. When the alkali-treated 316L-SS was soaked into SBF at a temperature of 80 degrees C, it could form a dense and uniform bone-like hydroxyapatite layer on the surface. In the research, the mechanism of the formation of sodium chromium oxide and HA would also be described by the analysis of X-ray diffractometer, scanning electron microscope, energy-dispersion spectrophotometer, and Fourier transformation infrared.

  20. Localized Corrosion Behavior of 6% Mo Super Austenitic & 316L Stainless Steels in Low pH 3% NaCl Solution

    Institute of Scientific and Technical Information of China (English)

    M.M.A.Gad; H.G.Salem; A.M. Nasreldin; H.Sabry; A.A.El-Sayed

    2005-01-01

    Electrochemical techniques were applied to study the crevice corrosion resistance of two types of stainless steel alloys namely, conventional 316L and 6% Mo super austenitic in acidified 3% NaCl solution at room temperature.Potentiodynamic results showed that 6% Mo alloy possessed a remarkable resistance to crevice corrosion compared with 316L alloy when they are tested in the same solution. The breakdown potential at which passivity broke down for 316L alloy was 0.00 mV (SCE). The corresponding value for 6% Mo alloy could not reach up to the potential value of 700 mV (SCE). 316L alloy suffered extremely from crevice corrosion at room temperature (about 25℃), which indicates that the critical crevice corrosion temperature, below which crevice corrosion does not occur, was lower than the test temperature. For 6% Mo alloy, the critical crevice corrosion temperature was higher than the testing temperature. Electrochemical parameters indicated that 6% Mo alloy exhibited higher crevice corrosion resistance than 316L alloy.

  1. MC3T3-E1 cell response to stainless steel 316L with different surface treatments

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Hongyu [State Key Laboratory of Tribology, Department of Mechanical Engineering, Tsinghua University, Beijing 100084 (China); Han, Jianmin, E-mail: siyanghan@163.com [Dental Materials Laboratory, National Engineering Laboratory for Digital and Material Technology of Stomatology, Peking University School and Hospital of Stomatology, Beijing 100081 (China); Sun, Yulong [State Key Laboratory of Tribology, Department of Mechanical Engineering, Tsinghua University, Beijing 100084 (China); Huang, Yongling [Jinghang Biomedicine Engineering Division, Beijing Institute of Aeronautical Material, Beijing 100095 (China); Zhou, Ming [State Key Laboratory of Tribology, Department of Mechanical Engineering, Tsinghua University, Beijing 100084 (China)

    2015-11-01

    In the present study, stainless steel 316L samples with polishing, aluminum oxide blasting, and hydroxyapatite (HA) coating were prepared and characterized through a scanning electron microscope (SEM), optical interferometer (surface roughness, Sq), contact angle, surface composition and phase composition analyses. Osteoblast-like MC3T3-E1 cell adhesion on the samples was investigated by cell morphology using a SEM (4 h, 1 d, 3 d, 7 d), and cell proliferation was assessed by MTT method at 1 d, 3 d, and 7 d. In addition, adsorption of bovine serum albumin on the samples was evaluated at 1 h. The polished sample was smooth (Sq: 1.8 nm), and the blasted and HA coated samples were much rougher (Sq: 3.2 μm and 7.8 μm). Within 1 d of incubation, the HA coated samples showed the best cell morphology (e.g., flattened shape and complete spread), but there was no significant difference after 3 d and 7 d of incubation for all the samples. The absorbance value for the HA coated samples was the highest after 1 d and 3 d of incubation, indicating better cell viability. However, it reduced to the lowest value at 7 d. Protein adsorption on the HA coated samples was the highest at 1 h. The results indicate that rough stainless steel surface improves cell adhesion and morphology, and HA coating contributes to superior cell adhesion, but inhibits cell proliferation. - Highlights: • Rough stainless steel surface improves cell adhesion and proliferation. • HA coating results in superior cell morphology and cell attachment. • HA coating inhibits osteoblast cell proliferation after 7 d of incubation.

  2. Multilayered Zr-C/a-C film on stainless steel 316L as bipolar plates for proton exchange membrane fuel cells

    Science.gov (United States)

    Bi, Feifei; Peng, Linfa; Yi, Peiyun; Lai, Xinmin

    2016-05-01

    A multilayered zirconium-carbon/amorphous carbon (Zr-C/a-C) coating is synthesized by magnetron sputtering in order to improve the corrosion resistance and interfacial conductivity of stainless steel 316L (SS316L) as bipolar plates for proton exchange membrane fuel cells (PEMFCs). Zr-C/a-C film contains an outmost pure amorphous carbon layer and a sub zirconium containing carbon layer. Interfacial contact resistance (ICR) between carbon paper and coated SS316L decreases to 3.63 mΩ cm2 at 1.4 MPa. Potentiodynamic polarization results reveal that the corrosion potential of Zr-C/a-C coated sample is more positive than pure a-C coated sample and the current density is only 0.49 μA cm-2 at the cathode applied potential 0.6 V. Electrochemical impendence spectroscopy also indicates that multilayered Zr-C/a-C film coated SS316L has much higher charge transfer resistance than the bare sample. After potentiostatic polarization, ICR values are 3.92 mΩ cm2 and 3.82 mΩ cm2 in the simulated PEMFCs cathode and anode environment, respectively. Moreover, XPS analysis of the coated samples before and after potential holding tests shows little difference, which disclose the chemical stability of multilayered Zr-C/a-C film. Therefore, the multilayered Zr-C/a-C coating exhibits excellent performance in various aspects and is preferred for the application of stainless steel bipolar plates.

  3. Study on cerium-doped nano-TiO2 coatings for corrosion protection of 316 L stainless steel

    Science.gov (United States)

    Li, Suning; Wang, Qian; Chen, Tao; Zhou, Zhihua; Wang, Ying; Fu, Jiajun

    2012-04-01

    Many methods have been reported on improving the photogenerated cathodic protection of nano-TiO2 coatings for metals. In this work, nano-TiO2 coatings doped with cerium nitrate have been developed by sol-gel method for corrosion protection of 316 L stainless steel. Surface morphology, structure, and properties of the prepared coatings were investigated by X-ray diffraction, X-ray photoelectron spectroscopy, scanning electron microscopy and energy dispersive X-ray spectroscopy. The corrosion protection performance of the prepared coatings was evaluated in 3 wt% NaCl solution by using electrochemical techniques in the presence and absence of simulated sunlight illumination. The results indicated that the 1.2% Ce-TiO2 coating with three layers exhibited an excellent photogenerated cathodic protection under illumination attributed to the higher separation efficiency of electron-hole pairs and higher photoelectric conversion efficiency. The results also showed that after doping with an appropriate concentration of cerium nitrate, the anti-corrosion performance of the TiO2 coating was improved even without irradiation due to the self-healing property of cerium ions.

  4. TEM study of the nucleation of bubbles induced by He implantation in 316L industrial austenitic stainless steel

    Science.gov (United States)

    Jublot-Leclerc, S.; Lescoat, M.-L.; Fortuna, F.; Legras, L.; Li, X.; Gentils, A.

    2015-11-01

    10 keV He ions were implanted in-situ in a TEM into thin foils of 316L industrial austenitic stainless steel at temperatures ranging from 200 to 550 °C. As a result, overpressurized nanometric bubbles are created with density and size depending strongly on both the temperature and fluence of implantation. An investigation on their nucleation and growth is reported through a rigorous statistical analysis whose procedure, including the consideration of free surface effects, is detailed. In the parameter range considered, the results show that an increase of fluence promotes both the nucleation and growth of the bubbles whilst an increase of temperature enhances the growth of the bubbles at the expense of their nucleation. The confrontation of resulting activation energies with existing models for bubble nucleation enables the identification of the underlying mechanisms. In spite of slight differences resulting from different conditions of implantation among which the He concentration, He production rate and He/dpa ratio, it appears that the dominating mechanisms are the same as those obtained in metals in previous studies, which, in addition to corroborating literature results, shows the suitability of in-situ TEM experiments to simulate the production of helium in nuclear materials.

  5. An in vitro evaluation of novel NHA/zircon plasma coating on 316L stainless steel dental implant

    Directory of Open Access Journals (Sweden)

    Ebrahim Karamian

    2014-04-01

    Full Text Available The surface characteristics of an implant that influence the speed and strength of osseointegration include crystal structure and bioactivity. The aim of this study was to evaluate the bioactivity of a novel natural hydroxyapatite/zircon (NHA/zircon nanobiocomposite coating on 316L stainless steel (SS dental implants soaking in simulated body fluid. A novel NHA/zircon nanobiocomposite was fabricated with 0 (control, 5, 10, and 15 wt% of zircon in NHA using ball mill for 1 h. The composite mixture was coated on SS implants using a plasma spray method. Scanning electron microscopy (SEM was used to evaluate surface morphology, and X-ray diffraction (XRD was used to analyze phase composition and crystallinity (Xc. Further, calcium ion release was measured to evaluate the coated nanobiocomposite samples. The prepared NHA/zircon coating had a nanoscale morphological structure with a mean crystallite size of 30–40 nm in diameter and a bone-like composition, which is similar to that of the biological apatite of a bone. For the prepared NHA powder, high bioactivity was observed owing to the formation of apatite crystals on its surface. Both minimum crystallinity (Xc=41.1% and maximum bioactivity occurred in the sample containing 10 wt% of zircon because of minimum Xc and maximum biodegradation of the coating sample.

  6. An in vitro evaluation of novel NHA/zircon plasma coating on 316L stainless steel dental implant

    Institute of Scientific and Technical Information of China (English)

    Ebrahim Karamian; Mahmood Reza Kalantar Motamedi; Amirsalar Khandan; Parisa Soltani; Sahel Maghsoudi

    2014-01-01

    The surface characteristics of an implant that influence the speed and strength of osseointegration include crystal structure and bioactivity. The aim of this study was to evaluate the bioactivity of a novel natural hydroxyapatite/zircon (NHA/zircon) nanobiocomposite coating on 316L stainless steel (SS) dental implants soaking in simulated body fluid. A novel NHA/zircon nanobiocomposite was fabricated with 0 (control), 5, 10, and 15 wt%of zircon in NHA using ball mill for 1 h. The composite mixture was coated on SS implants using a plasma spray method. Scanning electron microscopy (SEM) was used to evaluate surface morphology, and X-ray diffraction (XRD) was used to analyze phase composition and crystallinity (Xc). Further, calcium ion release was measured to evaluate the coated nanobiocomposite samples. The prepared NHA/zircon coating had a nanoscale morphological structure with a mean crystallite size of 30-40 nm in diameter and a bone-like composition, which is similar to that of the biological apatite of a bone. For the prepared NHA powder, high bioactivity was observed owing to the formation of apatite crystals on its surface. Both minimum crystallinity (Xc = 41.1%) and maximum bioactivity occurred in the sample containing 10 wt%of zircon because of minimum Xc and maximum biodegradation of the coating sample.

  7. Effect of Austenitic and Austeno-Ferritic Electrodes on 2205 Duplex and 316L Austenitic Stainless Steel Dissimilar Welds

    Science.gov (United States)

    Verma, Jagesvar; Taiwade, Ravindra V.

    2016-09-01

    This study addresses the effect of different types of austenitic and austeno-ferritic electrodes (E309L, E309LMo and E2209) on the relationship between weldability, microstructure, mechanical properties and corrosion resistance of shielded metal arc welded duplex/austenitic (2205/316L) stainless steel dissimilar joints using the combined techniques of optical, scanning electron microscope, energy-dispersive spectrometer and electrochemical. The results indicated that the change in electrode composition led to microstructural variations in the welds with the development of different complex phases such as vermicular ferrite, lathy ferrite, widmanstatten and intragranular austenite. Mechanical properties of welded joints were diverged based on compositions and solidification modes; it was observed that ferritic mode solidified weld dominated property wise. However, the pitting corrosion resistance of all welds showed different behavior in chloride solution; moreover, weld with E2209 was superior, whereas E309L exhibited lower resistance. Higher degree of sensitization was observed in E2209 weld, while lesser in E309L weld. Optimum ferrite content was achieved in all welds.

  8. Optimum temperature on corrosion resistance for plasma ion nitrided 316L stainless steel in sea water solution

    Science.gov (United States)

    Chong, Sang-Ok; Kim, Seong-Jong

    2017-01-01

    The aim of this research is to investigate the optimum plasma ion nitriding temperature on corrosion resistance in natural sea water for plasma ion nitrided 316L stainless steel. Plasma ion nitriding was conducted at different temperatures of 350, 400, 450, and 500 °C with a mixture of 75% of nitrogen and 25% of hydrogen during 10 h. In conclusion of anodic polarization test, a wide passive potential region and a high corrosion potential were observed at a plasma ion nitriding temperature of 450 °C. Moreover, relatively less damage depth and clean surface micrographs were observed at 450 °C as results of observation of three-dimensional (3D) microscope and scanning electron microscope (SEM) after polarization experiments. In addition, higher corrosion potential and lower corrosion current density were indicated at plasma ion nitrided samples than the value of untreated substrate after Tafel analysis. Hence, plasma ion nitrided at 450 °C in sea water solution represented optimum corrosion resistance among the all the plasma ion nitriding temperature parameters.

  9. Reduced platelet adhesion and improved corrosion resistance of superhydrophobic TiO₂-nanotube-coated 316L stainless steel.

    Science.gov (United States)

    Huang, Qiaoling; Yang, Yun; Hu, Ronggang; Lin, Changjian; Sun, Lan; Vogler, Erwin A

    2015-01-01

    Superhydrophilic and superhydrophobic TiO2 nanotube (TNT) arrays were fabricated on 316L stainless steel (SS) to improve corrosion resistance and hemocompatibility of SS. Vertically-aligned superhydrophilic amorphous TNTs were fabricated on SS by electrochemical anodization of Ti films deposited on SS. Calcination was carried out to induce anatase phase (superhydrophilic), and fluorosilanization was used to convert superhydrophilicity to superhydrophobicity. The morphology, structure and surface wettability of the samples were characterized by scanning electron microscopy (SEM), X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), and contact angle goniometry. The effects of surface wettability on corrosion resistance and platelet adhesion were investigated. The results showed that crystalline phase (anatase vs. amorphous) and wettability strongly affected corrosion resistance and platelet adhesion. The superhydrophilic amorphous TNTs failed to protect SS from corrosion whereas superhydrophobic amorphous TNTs slightly improved corrosion resistance of SS. Both superhydrophilic and superhydrophobic anatase TNTs significantly improved corrosion resistance of SS. The superhydrophilic amorphous TNTs minimized platelet adhesion and activation whereas superhydrophilic anatase TNTs activated the formation of fibrin network. On the contrary, both superhydrophobic TNTs (superhydrophobic amorphous TNTs and superhydrophobic anatase TNTs) reduced platelet adhesion significantly and improved corrosion resistance regardless of crystalline phase. Superhydrophobic anatase TNTs coating on SS surface offers the opportunity for the application of SS as a promising permanent biomaterial in blood contacting biomedical devices, where both reducing platelets adhesion/activation and improving corrosion resistance can be effectively combined.

  10. Effect of Austenitic and Austeno-Ferritic Electrodes on 2205 Duplex and 316L Austenitic Stainless Steel Dissimilar Welds

    Science.gov (United States)

    Verma, Jagesvar; Taiwade, Ravindra V.

    2016-11-01

    This study addresses the effect of different types of austenitic and austeno-ferritic electrodes (E309L, E309LMo and E2209) on the relationship between weldability, microstructure, mechanical properties and corrosion resistance of shielded metal arc welded duplex/austenitic (2205/316L) stainless steel dissimilar joints using the combined techniques of optical, scanning electron microscope, energy-dispersive spectrometer and electrochemical. The results indicated that the change in electrode composition led to microstructural variations in the welds with the development of different complex phases such as vermicular ferrite, lathy ferrite, widmanstatten and intragranular austenite. Mechanical properties of welded joints were diverged based on compositions and solidification modes; it was observed that ferritic mode solidified weld dominated property wise. However, the pitting corrosion resistance of all welds showed different behavior in chloride solution; moreover, weld with E2209 was superior, whereas E309L exhibited lower resistance. Higher degree of sensitization was observed in E2209 weld, while lesser in E309L weld. Optimum ferrite content was achieved in all welds.

  11. Effect of tensile pre-strain at different orientation on martensitic transformation and mechanical properties of 316L stainless steel

    Science.gov (United States)

    Wibowo, F.; Zulfi, F. R.; Korda, A. A.

    2017-01-01

    Deformation induced martensite was studied in 316L stainless steel through tensile pre-strain deformation in the rolling direction (RD) and perpendicular to the rolling direction (LT) at various %pre-strain. The experiment was carried out at various given %pre-strain, which were 0%, 4.6%, 12%, 17.4%, and 25.2% for the RD, whereas for LT were 0%, 4.6%, 12%, 18%, and 26% for LT. Changes in the microstructure and mechanical properties were observed using optical microscope, tensile testing, hardness testing, and X-ray diffraction (XRD) analysis. The experimental results showed that the volume fraction of martensite was increased as the %pre-strain increased. In the same level of deformation by tensile pre-strain, the volume of martensite for RD was higher than that with LT direction. The ultimate tensile strength (UTS), yield strength (YS), and hardness of the steel were increased proportionally with the increases in %pre-strain, while the value of elongation and toughness were decreased with the increases in %pre-strain.

  12. An EBSD investigation on flow localization and microstructure evolution of 316L stainless steel for Gen IV reactor applications

    Science.gov (United States)

    Wu, Xianglin; Pan, Xiao; Mabon, James C.; Li, Meimei; Stubbins, James F.

    2007-09-01

    Type 316L stainless steel has been selected as a candidate structural material in a series of current accelerator driven systems and Generation IV reactor conceptual designs. The material is sensitive to irradiation damage in the temperature range of 150-400 °C: even low levels of irradiation exposure, as small as 0.1 dpa, can cause severe loss of ductility during tensile loading. This process, where the plastic flow becomes highly localized resulting in extremely low overall ductility, is referred as flow localization. The process controlling this confined flow is related to the difference between the yield and ultimate tensile strengths such that large irradiation-induced increases in the yield strength result in very limited plastic flow leading to necking after very small levels of uniform elongation. In this study, the microstructural evolution controlling flow localization is examined. It is found that twinning is an important deformation mechanism at lower temperatures since it promotes the strain hardening process. At higher temperatures, twinning becomes energetically impossible since the activation of twinning is determined by the critical twinning stress, which increases rapidly with temperature. Mechanical twinning and dislocation-based planar slip are competing mechanisms for plastic deformation.

  13. Dynamic strain ageing of deformed nitrogen-alloyed AISI 316 stainless steels

    Energy Technology Data Exchange (ETDEWEB)

    Ehrnsten, U.; Toivonen, A. [Materials and Structural Integrity, VTT Technical Research Centre of Finland, Kemistintie 3, P.O. Box 1704, FIN-02044 VTT (Finland); Ivanchenko, M.; Nevdacha, V.; Yagozinskyy, Y.; Haenninen, H. [Department of Mechanical Engineering, Helsinki University of Technology Puumiehenkuja 3, P.O. Box 4200, FIN-02015 HUT (Finland)

    2004-07-01

    Intergranular stress corrosion cracking has occurred in BWR environment in non-sensitized, deformed austenitic stainless steel materials. The affecting parameters are so far not fully known, but deformation mechanisms may be decisive. The effect of deformation and nitrogen content on the behaviour of austenitic stainless steels was investigated. The materials were austenitic stainless steels of AISI 316L type with different amounts of nitrogen (0.03 - 0.18%) and they were mechanically deformed 0, 5 and 20%. The investigations are focused on the dynamic strain ageing (DSA) behaviour. A few crack growth rate measurements are performed on nuclear grade AISI 316NG material with different degrees of deformation (0, 5 and 20%). The effects of DSA on mechanical properties of these materials are evaluated based on peaks in ultimate tensile strength and strain hardening coefficient and minimum in ductility in the DSA temperature range. Additionally, internal friction measurements have been performed in the temperature range of -100 to 600 deg. C for determining nitrogen interactions with other alloying elements and dislocations (cold-worked samples). The results show an effect of nitrogen on the stainless steel behaviour, e.g. clear indications of dynamic strain ageing and changes in the internal friction peaks as a function of nitrogen content and amount of deformation. (authors)

  14. Degradation of 316L stainless steel sternal wire by steam sterilization.

    Science.gov (United States)

    Shih, Chun-Che; Su, Yea-Yang; Chen, Lung-Ching; Shih, Chun-Ming; Lin, Shing-Jong

    2010-06-01

    Sterilization is an important step prior to the implantation of medical devices inside the human body. In this work we studied the influence of steam sterilization cycles on the oxide film properties of stainless steel sternal wire. Characterization techniques such as open- circuit potential, potentiodynamic measurement, electrochemical impedance spectroscopy, cathodic stripping, transmission electron microscopy, atomic force microscopy and scanning electron microscopy were employed to investigate the cycles of steam sterilization on the corrosion behavior of sternal wire. The results showed that the oxide properties are a function of the number of steam sterilization cycles and deteriorate as the number of cycles increases. Steam sterilization might damage the implant integrity and heavy metals could be released to the surrounding tissues due to deterioration of the oxide film.

  15. Effect of temperature, chloride ions and sulfide ions on the electrochemical properties of 316L stainless steel in simulated cooling water

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    The influence of temperature, chloride ions and sulfide ions on the anticorrosion behavior of 316L stainless steel in simulated cooling water was studied by electrochemical impedance spectroscopy and anodic polarization curves. The results show that the film resistance increases with the solution temperature but decreases after 8 days' immersion, which indicates that the film formed at higher temperature has inferior anticorrosion behavior; Chloride ions and sulfide ions have remarkable effects on the elect...

  16. Characterization of Porous TiO2 Surfaces Formed on 316L Stainless Steel by Plasma Electrolytic Oxidation for Stent Applications

    OpenAIRE

    Iulian Apachitei; Jurek Duszczyk; Zhiguang Huan; Fratila-Apachitei, Lidy E.

    2011-01-01

    In this study, a porous oxide layer was formed on the surface of 316L stainless steel (SS) by combining Ti magnetron sputtering and plasma electrolytic oxidation (PEO) with the    aim to produce a polymer-free drug carrier for drug eluting stent (DES) applications. The oxidation was performed galvanostatically in Na3PO4 electrolyte. The surface porosity, average pore size and roughness varied with PEO treatment duration, and under optimum conditio...

  17. Estudio in vitro de la citotoxicidad y genotoxicidad de los productos liberados del acero inoxidable 316L con recubrimientos cerámicos bioactivos Cytotoxic and genotoxic study of in Vitro released products of stainless Steel 316l with bioactive ceramic Coatings

    Directory of Open Access Journals (Sweden)

    María Elena Márquez Fernández

    2007-03-01

    Full Text Available El acero inoxidable AISI 316L es el biomaterial mas utilizado para la fabricación de implantes temporales, pero presenta limitaciones para implantes permanentes debido a la liberación de iones metálicos hacia los tejidos circundantes, produciendo especies reactivas de oxígeno (ERO y daño en ADN, factores que aumentan el riesgo de aparición de tumores locales y fallas mecánicas del implante. Una estrategia utilizada para disminuir la liberación de iones es la modificación superficial de los implantes metálicos por medio de recubrimientos inorgánicos, cerámicos o vítreos, aplicados por el método sol-gel, el cual presenta una serie de ventajas comparativas con otras técnicas de deposición, como buena adherencia, aplicación sencilla, mínimos problemas de secado, bajas temperaturas de densificación y posibilidad de agregar partículas y/o grupos orgánicos que mejoran la adherencia celular al implante aumentando su biocompatibilidad. En el presente trabajo se evaluaron los efectos citotóxico por medio de la técnica MTT, y genotóxico por electroforesis en gel de células individuales (Ensayo Cometa, sobre células de la línea celular CHO, de los productos liberados en medio MEM por el acero inoxidable 316L sin recubrir, recubierto con una monocapa de vidrio de sílice (MC, o con doble capa que contiene partículas bioactivas de hidroxiapatita (HA, vidrio (V o vitrocerámico (VC, después de un periodo de 30 días. Los resultados muestran que a los 30 días de envejecimiento en medio MEM no se encuentra ningún efecto citotóxico, pero se encontró efecto genotóxico en las probetas de A y MC que no representa un peligro inminente a sistemas celulares. The stainless steel AISI 316L is the must used biomaterial for the making of temporal prosthesis, but it presents severe limitations for permanent implants due to the generation and migration of metallic ions to the surrounding peripheral tissues, which produces oxygen reactive

  18. The hardiness of numerical simulation of TIG welding. Application to stainless steel 316L structures; La robustesse de la simulation numerique du soudage TIG. Application sur des structures en acier 316L

    Energy Technology Data Exchange (ETDEWEB)

    El-Ahmar, Walid; Jullien, Jean-Francois [INSA-Lyon, LaMCoS, CNRS UMR 551, 20 Avenue Albert Einstein, 69621 Villeurbanne, (France); Gilles, Philippe [AREVA NP, 92084 Paris La Defense, (France); Taheri, Said [EDF, 92141 Clamart, (France); Boitout, Frederic [ESI-GROUP, 69458 Lyon, (France)

    2006-07-01

    The welding numerical simulation is considered as one of the mechanics problems the most un-linear on account of the great number of the parameters required. The analysis of the hardiness of the welding numerical simulation is a current questioning whose expectation is to specify welding numerical simulation procedures allowing to guarantee the reliability of the numerical result. In this work has been quantified the aspect 'uncertainties-sensitivity' imputable to different parameters which occur in the simulation of stainless steel 316L structures welded by the TIG process: that is to say the mechanical and thermophysical parameters, the types of modeling, the adopted behaviour laws, the modeling of the heat contribution.. (O.M.)

  19. 医用316L不锈钢表面改性的研究进展%Research Progress in Surface Modification of Biomedical 316L Stainless Steel

    Institute of Scientific and Technical Information of China (English)

    孙建华; 刘金龙; 王庆良; 吴高峰

    2011-01-01

    316L不锈钢作为生物医用材料在近20年内被广泛应用在矫形外科植入物、牙种植体和冠状动脉支架等领域.分析了目前医用316L不锈钢在临床应用中存在的主要问题.指出生物相客性、耐腐蚀性和耐磨损性有待提高和表面改性是改善上述问题的有效途径.综述了医用316L不锈钢表面改性的各种途径及研究成果,并展望了316L不锈钢表面改性的研究趋势.%316L stainless steel is an extensively used biomedical material for orthopedic implants, dental implant and cardiovascular stents in the last two decades. Based on the primary problem of biomedical 316L stainless steel in biocompatibility, corrosion resistance and wear resistance properties, it is pointed out that surface modifacation is an effective way to improve these properties. The various approaches and research achievement of surface modification for biomeical 316L stainless steel are reviewed, and the research trend of surface modification is also presented.

  20. The covalent immobilization of heparin to pulsed-plasma polymeric allylamine films on 316L stainless steel and the resulting effects on hemocompatibility.

    Science.gov (United States)

    Yang, Zhilu; Wang, Jin; Luo, Rifang; Maitz, Manfred F; Jing, Fengjuan; Sun, Hong; Huang, Nan

    2010-03-01

    For an improved hemocompatibility of 316L stainless steel (SS), we develop a facile and effective approach to fabricating a pulsed-plasma polymeric allylamine (P-PPAm) film that possesses a high cross-linking degree and a high density of amine groups, which is used for subsequent bonding of heparin. The P-PPAm film as a stent coating shows good resistance to the deformation behavior of compression and expansion of a stent. Using deionized water as an aging medium, it is demonstrated that the heparin-immobilized P-PPAm (Hep-P-PPAm) surface has a good retention of heparin. The systematic in vitro hemocompatibility evaluation reveals lower platelet adhesion, platelet activation and fibrinogen activation on the Hep-P-PPAm surface, and the activated partial thromboplastin time prolongs for about 15 s compared with 316L SS. The P-PPAm surface significantly promotes adhesion and proliferation of endothelial cells (ECs). For the Hep-P-PPAm, although EC adhesion and proliferation is slightly suppressed initially, after cultivation for 3 days, the growth behavior of ECs is remarkably improved over 316L SS. In vivo results indicate that the Hep-P-PPAm surface successfully restrain thrombus formation by growing a homogeneous and intact shuttle-like endothelium on its surface. The Hep-P-PPAm modified 316L SS shows a promising application for vascular devices.

  1. L2 Milestone 5433: Characterization of Dynamic Behavior of AM and Conventionally Processed Stainless Steel (316L and 304L)

    Energy Technology Data Exchange (ETDEWEB)

    Gray, George Thompson [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Livescu, Veronica [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Rigg, P. A. [Washington State Univ., Pullman, WA (United States). Inst. for Shock Physics; Trujillo, Carl Patrick [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Cady, Carl McElhinney [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Chen, Shuh-Rong [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Carpenter, John S. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Lienert, Thomas J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Fensin, Saryu Jindal [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Knapp, Cameron M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Beal, Roberta Ann [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Morrow, Benjamin [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dippo, Olivia F. [Univ. of California, San Diego, CA (United States); Jones, David Robert [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Martinez, Daniel Tito [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Valdez, James Anthony [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-09-26

    For additive manufacturing (AM) of metallic materials, the certification and qualification paradigm needs to evolve as there currently exists no broadly accepted “ASTM- or DIN-type” additive manufacturing certified process or AM-material produced specifications. Accordingly, design, manufacture, and thereafter implementation and insertion of AM materials to meet engineering applications requires detailed quantification of the constitutive (strength and damage) properties of these evolving materials, across the spectrum of metallic AM methods, in comparison/contrast to conventionally-manufactured metals and alloys. This report summarizes the 316L SS research results and presents initial results of the follow-on study of 304L SS. For the AM-316L SS investigation, cylindrical samples of 316L SS were produced using a LENS MR-7 laser additive manufacturing system from Optomec (Albuquerque, NM) equipped with a 1kW Yb-fiber laser. The microstructure of the AM-316L SS was characterized in both the “as-built” Additively Manufactured state and following a heat-treatment designed to obtain full recrystallization to facilitate comparison with annealed wrought 316L SS. The dynamic shock-loading-induced damage evolution and failure response of all three 316L SS materials was quantified using flyer-plate impact driven spallation experiments at peak stresses of 4.5 and 6.35 GPa. The results of these studies are reported in detail in the first section of the report. Publication of the 316L SS results in an archival journal is planned. Following on from the 316L SS completed work, initial results on a study of AM 304L SS are in progress and presented herein. Preliminary results on the structure/dynamic spallation property behavior of AM-304L SS fabricated using both the directed-energy LENS and an EOS powder-bed AM techniques in comparison to wrought 304L SS is detailed in this Level 2 Milestone report.

  2. Influence of the Carbo-Chromization Process on the Microstructural, Hardness, and Corrosion Properties of 316L Sintered Stainless Steel

    Science.gov (United States)

    Iorga, Sorin; Cojocaru, Mihai; Chivu, Adriana; Ciuca, Sorin; Burdusel, Mihail; Badica, Petre; Leuvrey, Cédric; Schmerber, Guy; Ulhaq-Bouillet, Corinne; Colis, Silviu

    2014-06-01

    We report on the changes on the microstructural, hardness, and corrosion properties induced by carbo-chromization of 316L stainless steel prepared by Spark Plasma Sintering technique. The thermo-chemical treatments have been performed using pack cementation. The carburizing and chromization were carried out between 1153 K (880 °C)/4 h to 1253 K (980 °C)/12 h and 1223 K (950 °C)/6 h to 1273 K (1000 °C)/12 h in a solid powder mixture of charcoal/BaCO3 and ferrochromium/alumina/NH4Cl, respectively. The obtained layers were investigated using X-ray and electron diffraction, optical and scanning electron microscopies, Vickers micro-hardness, and potentiodynamic measurements. The thickness of the carbo-chromized layer ranges between 300 and 500 μm. Besides the host γ-phase, the layers are mainly constituted of carbides (Fe7C3, Cr23C6, Cr7C3, and Fe3C) and traces of α'-martensite. The average hardness values decrease smoothly from 650 HV at the sample surface down to 200 HV at the center of the sample. The potentiodynamic tests revealed that the carbo-chromized samples have smaller corrosion resistance with respect to the untreated material. For strong chromization regimes, the corrosion rate is increased by a factor of four with respect to that of the untreated material, while the micro-hardness of the layer is three times larger. Such materials are suited to be used in environments where good corrosion resistance and wear properties are required.

  3. An electrochemical method for functionalization of a 316L stainless steel surface being used as a stent in coronary surgery: irreversible immobilization of fibronectin for the enhancement of endothelial cell attachment.

    Science.gov (United States)

    Harvey, Jeffrey; Bergdahl, Andreas; Dadafarin, Hesam; Ling, Li; Davis, Elaine C; Omanovic, Sasha

    2012-06-01

    An electrochemistry-based method for the formation of functionalized alkanethiol layers on a 316L stainless steel surface was developed. The method was efficient in forming a very stable, irreversibly-attached COOH-terminated (mercaptoundecanoic acid) surface layer. This layer was used as a 'linker' to immobilize the extracellular matrix protein fibronectin to the 316L stainless steel surface. Fibronectin was irreversibly attached to the surface and, unlike physisorbed fibronectin, resisted detachment more in aggressive 0.1 M NaOH under sonication. The fibronectin-modified 316L stainless steel surface was more biocompatible towards attachment of endothelial cells than a bare (unmodified) 316L stainless steel surface, yielding a 25% improvement in cell density.

  4. Comparing the Formability of AISI 304 and AISI 202 Stainless Steels

    Science.gov (United States)

    du Toit, M.; Steyn, H. G.

    2012-07-01

    The formability of AISI 202 austenitic stainless steel was compared with that of type AISI 304 stainless steel. Type 202 is a low-nickel austenitic stainless steel alloyed with manganese and nitrogen. In this study, the formability of the two grades was examined using Erichsen cupping tests and room temperature uniaxial tensile tests performed at various angles to the rolling direction. AISI 202 appears to work-harden at a slightly higher rate than AISI 304, even though the austenite in type 202 is more stable than that in 304 with respect to the formation of deformation-induced α' martensite. Although both grades are predicted to be susceptible to earing during deep drawing, AISI 202 displays a higher work-hardening exponent, higher average normal anisotropy, and a higher limiting drawing ratio than AISI 304. Similar cup heights were measured during Erichsen cupping tests, confirming that the two grades have very similar deep drawing properties. The results of this investigation therefore suggest that AISI 202 is a suitable alternative for AISI 304 in applications requiring good deep drawing properties.

  5. Effect of Surface Condition and Heat Treatment on Corrosion of Type 316L Stainless Steel in a Mercury Thermal Convection Loop

    Energy Technology Data Exchange (ETDEWEB)

    Pawel, S J

    2001-09-25

    Two thermal convection loops (TCLs) fabricated from 316L stainless steel and containing mercury and a variety of 316L coupons representing variable surface conditions and heat treatments have been operated continuously for 2000 h. Surface conditions included surface ground, polished, gold-coated, chemically etched, bombarded with Fe to simulate radiation damage, and oxidized. Heat treatments included solution treated, welded, and sensitized. In addition, a nitrogen doped 316L material, termed 316LN, was also examined in the solution treated condition. Duplicate TCLs were operated in this experiment--both were operated with a 305 C peak temperature, a 65 C temperature gradient, and mercury velocity of 1.2 m/min--but only one included a 36 h soak in Hg at 310 C just prior to operation to encourage wetting. Results indicate that the soak in Hg at 310 C had no lasting effect on wetting or compatibility with Hg. Further, based on examination of post-test wetting and coupon weight loss, only the gold-coated surfaces revealed significant interaction with Hg. In areas wetted significantly by Hg, the extreme surface of the stainless steel (ca 10 {micro}m) was depleted in Ni and Cr compared to the bulk composition.

  6. Effect of Surface Condition and Heat Treatment on Corrosion of Type 316L Stainless Steel in a Mercury Thermal Convection Loop

    Energy Technology Data Exchange (ETDEWEB)

    Pawel, S.J.

    2000-10-17

    Two thermal convection loops (TCLs) fabricated from 316L stainless steel and containing mercury and a variety of 316L coupons representing variable surface conditions and heat treatments have been operated continuously for 2000 h. Surface conditions included surface ground, polished, gold-coated, chemically etched, bombarded with Fe to simulate radiation damage, and oxidized. Heat treatments included solution treated, welded, and sensitized. In addition, a nitrogen doped 316L material, termed 316LN, was also examined in the solution treated condition. Duplicate TCLs were operated in this experiment--both were operated with a 305 C peak temperature, a 65 C temperature gradient, and mercury velocity of 1.2 m/min--but only one included a 36 h soak in Hg at 310 C just prior to operation to encourage wetting. Results indicate that the soak in Hg at 310 C had no lasting effect on wetting or compatibility with Hg. Further, based on examination of post-test wetting and coupon weight loss, only the gold-coated surfaces revealed significant interaction with Hg. In areas wetted significantly by Hg, the extreme surface of the stainless steel (ca 10 {micro}m) was depleted in Ni and Cr compared to the bulk composition.

  7. The Interfacial Microstructure and Mechanical Properties of Diffusion-Bonded Joints of 316L Stainless Steel and the 4J29 Kovar Alloy Using Nickel as an Interlayer

    Directory of Open Access Journals (Sweden)

    Tingfeng Song

    2016-11-01

    Full Text Available 316L stainless steel (Fe–18Cr–11Ni and a Kovar (Fe–29Ni–17Co or 4J29 alloy were diffusion-bonded via vacuum hot-pressing in a temperature range of 850–950 °C with an interval of 50 °C for 120 min and at 900 °C for 180 and 240 min, under a pressure of 34.66 MPa. Interfacial microstructures of diffusion-bonded joints were characterized by optical microscopy (OM, scanning electron microscopy (SEM, X-ray diffraction (XRD, and energy dispersive spectroscopy (EDS. The inter-diffusion of the elements across the diffusion interface was revealed via electron probe microanalysis (EPMA. The mechanical properties of the joints were investigated via micro Vickers hardness and tensile strength. The results show that an Ni interlayer can serve as an effective diffusion barrier for the bonding of 316L stainless steel and the 4J29 Kovar alloy. The composition of the joints was 316L/Ni s.s (Fe–Cr–Ni/remnant Ni/Ni s.s (Fe–Co–Ni/4J29. The highest tensile strength of 504.91 MPa with an elongation of 38.75% was obtained at 900 °C for 240 min. After the width of nickel solid solution (Fe–Co–Ni sufficiently increased, failure located at the 4J29 side and the fracture surface indicated a ductile nature.

  8. Metallic ions in organs of rats injected with metallic particles of stainless steel 316L and Ti6Al4V alloy

    Directory of Open Access Journals (Sweden)

    Silvia Helena Giertz

    2010-03-01

    Full Text Available Despite the interest in identifying systemic effects caused by the metallic particles released from long term metallic implants in the body, few works support reliable conclusions about the effects of those particles in organs. The aim of the present work is to look for damages in tissues of liver, kidney, lung and heart of rats submitted to injection of Hank's solution contained particles of Ti6Al4V alloy and Stainless Steel 316L, obtained by metal friction. The particles size ranges from 50 to 200 µm for the Ti alloy and from 100 to 500 µm for the 316L. Tissues isolated from the organs after the euthanasia were prepared and analyzed in an optical microscope and Energy Dispersive Spectrometer (EDS. Lesions caused by an inflammatory response such as strange body epithelioid granuloma and giant cells were found in some of the tissues containing yttrium and aluminum.

  9. A three dimensional discrete dislocation dynamics modelling of the early cycles of fatigue in an austenitic stainless steel 316L: dislocation microstructure and damage analysis; Modelisation physique des stades precurseurs de l'endommagement en fatigue dans l'acier inoxydable austenitique 316L

    Energy Technology Data Exchange (ETDEWEB)

    Depres, Ch

    2005-07-01

    A numerical code modelling the collective behaviour of dislocations at a mesoscopic scale (Discrete Dislocation Dynamics code) is used to analyse the cyclic plasticity that occurs in surface grains of an AISI 316L stainless steel, in order to understand the plastic mechanism involved in crack initiation in fatigue. Firstly, the analyses of both the formation and the evolution of the dislocation microstructures show the crucial role of cross-slip played in the strain localization in the form of slip bands. As the cycling proceeds, the slip bands exhibit well-organized dislocation arrangements that substitute to dislocation tangles, involving specific interaction mechanisms between primary and deviate systems. Secondly, both the surface displacements generated by plastic slip and the distortion energy induced by the dislocation microstructure have been analysed. We find that an irreversible surface relief in the form of extrusion/intrusion can be induced by cyclic slip of dislocations. The number of cycles for the crack initiation follows a Manson-Coffin type law. The analyses of the concentration of the distortion energy and its repartition in the slip bands show that beneficial energetic zones may be present at the very beginning of the cycling, and that mode-II crack propagation in the surface grains results from a succession of micro-crack initiations along primary slip plane, which is facilitated by various effects (stress concentration due to surface relief, environment effects...). Finally, a dislocation-based model for cyclic plasticity is proposed from Discrete Dislocation Dynamics results. (author)

  10. Effect of surface passivation on corrosion resistance and antibacterial properties of Cu-bearing 316L stainless steel

    Science.gov (United States)

    Zhao, Jinlong; Xu, Dake; Shahzad, M. Babar; Kang, Qiang; Sun, Ying; Sun, Ziqing; Zhang, Shuyuan; Ren, Ling; Yang, Chunguang; Yang, Ke

    2016-11-01

    The resistance for pitting corrosion, passive film stability and antibacterial performance of 316L-Cu SS passivated by nitric acid solution containing certain concentration of copper sulfate, were studied by electrochemical cyclic polarization, electrochemical impedance spectroscopy (EIS) and co-culture with bacteria. Inductively coupled plasma mass spectrometry (ICP-MS) was used to analyze the Cu2+ ions release from 316L-Cu SS surface. XPS analysis proved that the enrichment of CuO, Cr2O3 and Cr(OH)3 on the surface of specimen could simultaneously guarantee a better corrosion resistance and stable antibacterial properties. The biocompatibility evaluation determined by RTCA assay also indicated that the 316L-Cu SS after antibacterial passivation was completely biocompatible.

  11. Tensile properties of explosively formed 316L(N)-IG stainless steel with and without an electron beam weld

    NARCIS (Netherlands)

    Hegeman, J.B.J.; Luzginova, N.V.; Jong, M.; Groeneveld, H.D.; Borsboom, A.; Stuivinga, M.E.C.; Laan, J.G. van der

    2011-01-01

    The mechanical properties of two explosively formed saddle shaped 60 mm thick plates of 316L(N)-IG steel with and without an electron beam weld have been investigated. Two different conditions have been characterized: (1) Reference condition and (2) ITER relevant condition. The reference material ex

  12. Influence of Prior Fatigue Damage on Tensile Properties of 316L(N) Stainless Steel and Modified 9Cr-1Mo Steel

    Science.gov (United States)

    Mariappan, K.; Shankar, Vani; Sandhya, R.; Mathew, M. D.; Bhaduri, A. K.

    2015-02-01

    In the current study, the effect of prior low-cycle fatigue (LCF) damage on the tensile properties of 316L(N) stainless steel (SS) and modified 9Cr-1Mo steel were systematically investigated. The LCF tests were interrupted at 5, 10, 30, and 50 pct of the total fatigue life followed by tensile tests on the same specimens at the same strain rate (3 × 10-3 s-1) and temperatures of 300 K, 823 K, and 873 K (27 °C, 550 °C, and 600 °C). Prior strain cycling at elevated temperatures had remarkable effect on the tensile properties of both cyclically hardening and cyclically softening materials. An exponential relationship between the yield stress and the amount of pre-strain cycles is obtained for both the materials. The initial drastic change in the yield strength values up to 10 pct of fatigue life may be due to the microstructural changes that lead to hardening or softening in 316L(N) SS and modified 9Cr-1Mo steel, respectively. Saturation in the yield strength values beyond 10 pct of fatigue life has practical importance for remnant fatigue life assessment. Evolution of fatigue damage in both the 316L(N) SS and modified 9Cr-1Mo steel was analyzed using the surface replica technique.

  13. The Kinetics of Anodic Dissolution and Repassivation on 316L Stainless Steel in Borate Buffer Solution Studied by Abrading Electrode Technique

    Energy Technology Data Exchange (ETDEWEB)

    Xu, H. S.; Sun, D. B.; Yu, H. Y.; Meng, H. M. [University of Science and Technology Beijing, Beijing (China)

    2015-12-15

    The capacity of passive metal to repassivate after film damage determines the development of local corrosion and the resistance to corrosion failures. In this work, the repassivation kinetics of 316L stainless steel (316L SS) was investigated in borate buffer solution (pH 9.1) using a novel abrading electrode technique. The repassivation kinetics was analyzed in terms of the current density flowing from freshly bare 316L SS surface as measured by a potentiostatic method. During the early phase of decay (t < 2 s), according to the Avrami kinetics-based film growth model, the transient current was separated into anodic dissolution (i{sub diss}) and film formation (i{sub film}) components and analyzed individually. The film reformation rate and thickness were compared according to applied potential. Anodic dissolution initially dominated the repassivation for a short time, and the amount of dissolution increased with increasing applied potential in the passive region. Film growth at higher potentials occurred more rapidly compared to at lower potentials. Increasing the applied potential from 0 V{sub SCE} to 0.8 V{sub SCE} resulted in a thicker passive film (0.12 to 0.52 nm). If the oxide monolayer covered the entire bare surface (θ=1), the electric field strength through the thin passive film reached 1.6 x 10{sup 7} V/cm.

  14. The use of alkanethiol self-assembled monolayers on 316L stainless steel for coronary artery stent nanomedicine applications: an oxidative and in vitro stability study.

    Science.gov (United States)

    Mahapatro, Anil; Johnson, Dave M; Patel, Devang N; Feldman, Marc D; Ayon, Arturo A; Agrawal, C Mauli

    2006-09-01

    The use of self-assembled monolayers (SAMs) on medical devices offers a methodology for the incorporation of nanotechnology into medicine. SAMs are highly ordered nanosized molecular coatings, adding 1 to 10 nm thickness to a surface. This work is part of an overall goal to deliver therapeutic drugs from the surface of metal coronary stents using SAMs. In this study the oxidative and in vitro stability of functional alkylthiol SAMs on 316L stainless steel (SS) has been demonstrated. SAMs of 11-mercaptoundecanoic acid (-COOH SAM) and 11-mercapto-1-undecanol (-OH SAM) were formed on 316L SS. X-ray photoelectron spectroscopy (XPS), Fourier transform infrared spectroscopy (FTIR), and contact angle (CA) measurements collectively confirmed the formation of functional alkylthiol SAMs on 316L SS. Well-formed SAMs (CA: 82 deg +/- 9 deg) were achieved within 48 hours of immersion in ethanolic solutions, after which no significant improvement in CA was observed. The ratio of the thiolate peak (163.5 eV) to the oxidized sulfur (sulfonates) peak (166.5 eV) gives us an indication of the percentage SAMs that would bind to the metal and serve as a drug reservoir in vivo; which in turn represents the stability and viability of these SAMs, keeping in mind the cardiovascular application under consideration. Oxidative and in vitro stability studies showed that alkanethiol SAMs oxidized completely within 14 days. The SAMs tend to desorb and leave the metal surface after longer time periods (21 days) in phosphate-buffered saline (PBS) immersion, whereas for oxidative exposure the SAMs continue to remain on the metal surface in the form of sulfonates. Although the chemistry of bonding of alkylthiol with the 316L SS is not well understood, the nanosized alkylthiol SAMs demonstrate sufficient stability to justify further study on these systems for potential in vivo drug delivery in the chosen coronary artery stent applications.

  15. Nano-structure TiO2 film coating on 316L stainless steel via sol-gel technique for blood compatibility improvement

    Directory of Open Access Journals (Sweden)

    Mohammadreza Foruzanmehr

    2014-04-01

    Full Text Available   Objective(s: Titanium oxides are known to be appropriate hemocompatible materials which are suggested as coatings for blood-contacting devices. Little is known about the influence of nanometric crystal structure, layer thickness, and semiconducting characteristics of TiO2 on blood hemostasis.   Materials and Methods: Having used sol-gel dip coating method in this study, TiO2 thin films were deposited on nano-scale electro-polished stainless steel 316L with 1 to 5 nano-sized layers. Surface morphology and structure of the film were studied with X-ray diffraction and atomic force microscopy. Blood compatibility was also determined by measuring the platelet activation (CD62P expression, platelet adhesion (Scanning Electron Microscopy, and the blood clotting time on these samples. Results: The films were compact and smooth and existed mainly in the form of anatase. By increasing the number of TiO2 thin layer, clotting time greatly extended, and the population of activated platelet and P-selectine expression changed according to the surface characteristics of each layer. Conclusion: The findings revealed that stainless steel 316L coated with nano-structured TiO2 layer improved blood compatibility, in terms of both blood platelet activity and coagulation cascade, which can decrease the thrombogenicity of blood contacting devices which were made from stainless steel.

  16. Development and Characterization of 316 L Stainless Steel Coated by Melt-derived and Sol-gel derived 45S5 Bioglass for orthopedic applications

    Directory of Open Access Journals (Sweden)

    Seyed Morteza Naghib

    2012-03-01

    Full Text Available The 316L austenitic stainless steel (SS was coated by 45S5 bioactive glass produced by melting and sol-gel techniques to increase the bioactivity and to provide a high mechanical strength for orthopedic and dental applications. The morphologies of coated specimens were investigated by scanning electron microscopy (SEM. Then, the coated specimens were immersed in simulated body fluid (SBF at 37°C for 14 days, and their microstructures after withdrawal were also investigated by SEM. All the specimens were analyzed by FTIR and XRD in order to survey the formation of hydroxyapatite layer.

  17. Laser surface texturing of 316L stainless steel in air and water: A method for increasing hydrophilicity via direct creation of microstructures

    Science.gov (United States)

    Razi, Sepehr; Madanipour, Khosro; Mollabashi, Mahmoud

    2016-06-01

    Laser processing of materials in water contact is sometimes employed for improving the machining, cutting or welding quality. Here, we demonstrate surface patterning of stainless steel grade 316L by nano-second laser processing in air and water. Suitable adjustments of laser parameters offer a variety of surface patterns on the treated targets. Furthermore alterations of different surface features such as surface chemistry and wettability are investigated in various processing circumstances. More than surface morphology, remarkable differences are observed in the surface oxygen content and wettability of the samples treated in air and water at the same laser processing conditions. Mechanisms of the changes are discussed extensively.

  18. Comparative study of high temperature oxidation behaviour in AISI 304 and AISI 439 stainless steels

    Directory of Open Access Journals (Sweden)

    Antônio Claret Soares Sabioni

    2003-06-01

    Full Text Available This work deals with a comparison of high temperature oxidation behaviour in AISI 304 austenitic and AISI 439 ferritic stainless steels. The oxidation experiments were performed between 850 and 950 °C, in oxygen and Ar (100 vpm H2. In most cases, it was formed a Cr2O3 protective scale, whose growth kinetics follows a parabolic law. The exception was for the the AISI 304 steel, at 950 °C, in oxygen atmosphere, which forms an iron oxide external layer. The oxidation resistance of the AISI 439 does not depend on the atmosphere. The AISI 304 has the same oxidation resistance in both atmospheres, at 850 °C, but at higher temperatures, its oxidation rate strongly increases in oxygen atmosphere. Concerning the performance of these steels under oxidation, our results show that the AISI 439 steel has higher oxidation resistance in oxidizing atmosphere, above 850 °C, while, in low pO2 atmosphere, the AISI 304 steel has higher oxidation resistance than the AISI 439, in all the temperature range investigated.

  19. The passive oxide films growth on 316L stainless steel in borate buffer solution measured by real-time spectroscopic ellipsometry

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Haisong; Wang, Lu; Sun, Dongbai [National Center for Materials Service Safety (NCMS), University of Science and Technology Beijing, Beijing 100083 (China); Yu, Hongying, E-mail: hyyu@ustb.edu.cn [Institute of Advanced Materials and Technology, University of Science and Technology Beijing, Beijing 100083 (China)

    2015-10-01

    Highlights: • The optical properties of passive oxide films on 316L stainless steel were studied. • The thickness of the oxide films (1.5–2.6 nm) increased linearly with the potentials. • The growth of passive film followed high electric field ion conduction model. • Selective solubility of oxide induced compositional change of passive film. - Abstract: Passive film growth on 316L stainless steel was investigated in borate buffer electrolyte (pH = 9.1) by real-time spectroscopic ellipsometry (SE) and the composition was estimated by X-ray photoelectron spectroscopy (XPS). Anodic passivation of 316L SS was carried out in the potential range from 0 V{sub SCE} to 0.9 V{sub SCE}, after potentiostatic polarization for 1800s, the current density decayed from 10{sup −2} A cm{sup −2} to 10{sup −6} A cm{sup −2}. The passive film thickness was simulated from Frenel and Drude reflection equations, the average complex refractive index was assumed to be N = 2.3 − j0.445. The estimated thickness increased linearly with potential from 1.5 nm at 0 V to 2.6 nm at 0.8 V. The growth of passive film followed high electric field ion conduction model. The passive film mainly contained the oxide/hydroxide of iron and chromium. The selective solubility of oxide in passive film explained the change of iron and chromium content at different potentials. Few nickel and molybdenum also contributed to the passive film with a constant content.

  20. In-vitro bioactivity, biocorrosion and antibacterial activity of silicon integrated hydroxyapatite/chitosan composite coating on 316 L stainless steel implants.

    Science.gov (United States)

    Sutha, S; Kavitha, K; Karunakaran, G; Rajendran, V

    2013-10-01

    A simple and effective ultrasonication method was applied for the preparation of 0, 0.4, 0.8, 1.0 and 1.6 wt% silicon substituted hydroxyapatite (HAp) (SH). The Ca/P ratio of the synthesised SH nanoparticles were in the range of 1.58-1.70. Morphological changes were noticed in HAp with respect to the amount of Si from 0 to 1.6 wt%. The morphology of the particles changed from spherical shape to rod-like morphology with respect to the amount of Si which was confirmed using transmission electron microscopy. X-ray diffraction studies confirm the formation of phase pure SH nanoparticles without any secondary phase. Chitosan (CTS) blended SH nanocomposites coating on surgical grade 316 L stainless steel (316 L SS) implant was made by spin coating technique. The surface of the coated implant was characterised using scanning electron microscopy which confirms the uniform coating without cracks and pores. The increased corrosion resistance of the 1.6 wt% of SH/CTS-coated SS implant in the simulated body fluid (SBF) indicates the long-term biostability of SH composite-coated ceramics in vitro than the 0 wt% SH/CTS. The testing of SH/CTS nanocomposites with gram-positive and gram-negative bacterial strains confirms that the antibacterial ability improves with the higher substitution of Si. In addition, formation of bone-like apatite layer on the SH/CTS-coated implant in SBF was studied through SEM analysis and it confirms the ability to increase the HAp formation on the surface of 1.0 wt% SH/CTS-coated 316 L SS implant.

  1. Immobilization of the direct thrombin inhibitor-bivalirudin on 316L stainless steel via polydopamine and the resulting effects on hemocompatibility in vitro.

    Science.gov (United States)

    Lu, Lei; Li, Quan-Li; Maitz, Manfred F; Chen, Jia-Long; Huang, Nan

    2012-09-01

    Bivalirudin (BV), a peptidic direct thrombin inhibitor, derived from hirudin, has gained increasing interest in clinical anticoagulant therapy in the recent years. In this work, a hemocompatible surface was prepared by immobilization of BV on 316L stainless steel (SS) using a bonding layer of polydopamine (DA). X-ray photoelectron spectroscopy (XPS) was used to determine the chemical composition of the surfaces to characterize polydopamine intermediate layer and the immobilized BV. The quantity of bound BV was measured by quartz crystal microbalance (QCM). The hemocompatibility in vitro was evaluated by coagulating time of activated partial thromboplastin time (aPTT) and prothrombin time (PT) assay, platelet adhesion and activation, fibrinogen adsorption, and activation and whole blood test. The effect of sterilizing method on the bioactivity of immobilized BV was also evaluated. The results showed that BVs were successfully immobilized on SS surface with the DA interlayer at a density of 98 ng/cm(2) . BV coating surface prolonged aPTT and PT, inhibited the activation of platelet and fibrinogen significantly. Sterilization by ultraviolet radiation was possible with only marginal loss of activity. Thus, the approach described here may provide a basis for the preparation of 316L SS surface modification for use in cardiovascular implants.

  2. Effect of Oxygen Content Upon the Microstructural and Mechanical Properties of Type 316L Austenitic Stainless Steel Manufactured by Hot Isostatic Pressing

    Science.gov (United States)

    Cooper, Adam J.; Cooper, Norman I.; Dhers, Jean; Sherry, Andrew H.

    2016-09-01

    Although hot isostatic pressing (HIP) has been shown to demonstrate significant advances over more conventional manufacture routes, it is important to appreciate and quantify the detrimental effects of oxygen involvement during the HIP manufacture process on the microstructural and material properties of the resulting component. This paper quantifies the effects of oxygen content on the microstructure and Charpy impact properties of HIP'd austenitic stainless steel, through combination of detailed metallographic examination and mechanical testing on HIP'd Type 316L steel containing different concentrations (100 to 190 ppm) of oxygen. Micron-scale pores were visible in the microstructure of the HIP'd materials postmetallographic preparation, which result from the removal of nonmetallic oxide inclusions during metallographic preparation. The area fraction of the resulting pores is shown to correlate with the oxygen concentration which influences the Charpy impact toughness over the temperature range of 77 K to 573 K (-196 °C to 300 °C), and demonstrates the influence of oxygen involved during the HIP manufacture process on Charpy toughness. The same test procedures and microstructural analyses were performed on commercially available forged 316L. This showed comparatively fewer inclusions and exhibited higher Charpy impact toughness over the tested temperature range.

  3. Electrochemical behavior of nanocrystalline Ta/TaN multilayer on 316L stainless steel: Novel bipolar plates for proton exchange membrane fuel-cells

    Science.gov (United States)

    Alishahi, M.; Mahboubi, F.; Mousavi Khoie, S. M.; Aparicio, M.; Hübner, R.; Soldera, F.; Gago, R.

    2016-08-01

    Insufficient corrosion resistance and surface conductivity are two main issues that plague large-scale application of stainless steel (SS) bipolar plates in proton exchange membrane fuel cells (PEMFCs). This study explores the use of nanocrystalline Ta/TaN multilayer coatings to improve the electrical and electrochemical performance of polished 316L SS bipolar plates. The multilayer coatings have been deposited by (reactive) magnetron sputtering and characterized by X-ray diffraction, field-emission scanning electron microscopy and transmission electron microscopy. The electrochemical behavior of bare and coated substrates has been evaluated in simulated PEMFC working environments by potentiodynamic and potentiostatic polarization tests at ambient temperature and 80 °C. The results show that the Ta/TaN multilayer coating increases the polarization resistance of 316L SS by about 30 and 104 times at ambient and elevated temperatures, respectively. The interfacial contact resistance (ICR) shows a low value of 12 mΩ × cm2 before the potentiostatic test. This ICR is significantly lower than for the bare substrate and remains mostly unchanged after potentiostatic polarization for 14 h. In addition, the high contact angle (92°) with water for coated substrates indicates a hydrophobic character, which can improve the water management within the cell in PEMFC stacks.

  4. Evaluation of the Effect of Dynamic Sodium on the Low Cycle Fatigue Properties of 316L(N) Stainless Steel Base and Weld Joints

    Science.gov (United States)

    Ganesan, V.; Kannan, R.; Mariappan, K.; Sukumaran, G.; Sandhya, R.; Rao, K. Bhanu Sankara

    2012-06-01

    Low cycle fatigue (LCF) tests on 316L(N) austenitic stainless steel base and weld joints were at 823 K and 873 K at a constant strain rate of 3 × 10 -3 s -1 with strain ranges varying from {±}0.4% to {±}1.0% in a servo-hydraulic fatigue test system under flowing sodium environment. The cyclic stress response exhibited a similar trend as that in air comprising of an initial rapid hardening, followed by a slight softening stage before saturation. The fatigue lives are significantly improved in sodium environment when compared to identical testing conditions in air environment. The lack of oxidation in sodium environment is attributed to the delayed crack initiation, reduced crack propagation rate and consequent increase in fatigue life. Comparison of the data evaluated in sodium with RCC-MR design code, derived on the basis of data obtained from air shows that the design based on air tests is conservative.

  5. Radiation-induced segregation and corrosion behavior on Σ3 coincidence site lattice and random grain boundaries in proton-irradiated type-316L austenitic stainless steel

    Energy Technology Data Exchange (ETDEWEB)

    Sakaguchi, N., E-mail: sakaguchi@eng.hokudai.ac.jp [Center for Advanced Research of Energy and Materials, Faculty of Engineering, Hokkaido University, Sapporo 060-8628, Hokkaido (Japan); Endo, M.; Watanabe, S. [Center for Advanced Research of Energy and Materials, Faculty of Engineering, Hokkaido University, Sapporo 060-8628, Hokkaido (Japan); Kinoshita, H. [Fukushima National College of Technology, Iwaki 970-8034, Fukushima (Japan); Yamashita, S. [Fuels and Materials Department, O-arai Research and Development Center, Japan Atomic Energy Agency, Ibaraki 311-1393 (Japan); Kokawa, H. [Graduate School of Engineering, Tohoku University, Sendai 980-8579 (Japan)

    2013-03-15

    The behavior of radiation-induced segregation (RIS) and intergranular corrosion at random grain boundaries and Σ3 coincidence site lattice (CSL) boundaries in proton-irradiated 316L stainless steel was examined. The frequency of the CSL boundaries was enhanced up to 86.6% by grain boundary engineering treatment prior to irradiation. Significant nickel enrichment and chromium depletion were induced at the random grain boundary owing to the RIS. At faceted Σ3 CSL boundaries, chromium depletion occurred at the asymmetrical boundary facet plane whereas no RIS was observed at the coherent twin boundary. After the electrochemical etching test, an intergranular corrosion groove was found along the random grain boundaries because of the low chromium concentration (∼12%) at the boundaries. At the faceted Σ3 CSL boundaries, the discontinuous groove along the asymmetric facet plane was completely disrupted by the non-corrosive coherent twin boundary.

  6. Electropolishing of Re-melted SLM Stainless Steel 316L Parts Using Deep Eutectic Solvents: 3 × 3 Full Factorial Design

    Science.gov (United States)

    Alrbaey, K.; Wimpenny, D. I.; Al-Barzinjy, A. A.; Moroz, A.

    2016-07-01

    This three-level three-factor full factorial study describes the effects of electropolishing using deep eutectic solvents on the surface roughness of re-melted 316L stainless steel samples produced by the selective laser melting (SLM) powder bed fusion additive manufacturing method. An improvement in the surface finish of re-melted stainless steel 316L parts was achieved by optimizing the processing parameters for a relatively environmentally friendly (`green') electropolishing process using a Choline Chloride ionic electrolyte. The results show that further improvement of the response value-average surface roughness ( Ra) can be obtained by electropolishing after re-melting to yield a 75% improvement compared to the as-built Ra. The best Ra value was less than 0.5 μm, obtained with a potential of 4 V, maintained for 30 min at 40 °C. Electropolishing has been shown to be effective at removing the residual oxide film formed during the re-melting process. The material dissolution during the process is not homogenous and is directed preferentially toward the iron and nickel, leaving the surface rich in chromium with potentially enhanced properties. The re-melted and polished surface of the samples gave an approximately 20% improvement in fatigue life at low stresses (approximately 570 MPa). The results of the study demonstrate that a combination of re-melting and electropolishing provides a flexible method for surface texture improvement which is capable of delivering a significant improvement in surface finish while holding the dimensional accuracy of parts within an acceptable range.

  7. Ion release and surface oxide composition of AISI 316L, Co–28Cr–6Mo, and Ti–6Al–4V alloys immersed in human serum albumin solutions

    Energy Technology Data Exchange (ETDEWEB)

    Karimi, Shima, E-mail: shimak80@gmail.com; Alfantazi, Akram M.

    2014-07-01

    The long-term weight loss, ion release, and surface composition of 316L, Co–28Cr–6Mo and Ti–6Al–4V alloys were investigated in a simulated body environment. The samples were immersed in phosphate-buffered saline (PBS) solutions with various human serum albumin (HSA) concentrations for 8, 14, and 22 weeks. The specimens initially lost weight up to 14 weeks and then slightly gained weight. The analysis of the released ions was performed by induced coupled plasma-optical emission spectrometer (ICP-OES). The results revealed that the precipitation of the dissolved Fe and Co could cause the weight gain of the 316L and Co–28Cr–6Mo alloys. The surface chemistry of the specimens was determined by X-ray photoelectron spectroscopy (XPS). The XPS analysis of Co–28Cr–6Mo alloy showed that the interaction of Mo with HSA is different from Mo with bovine serum albumin (BSA). This was also observed for Na adsorption into the oxide layer of Ti–6Al–4V alloy in the presence of HSA and BSA. - Highlights: • Long-term study of weight loss, ion release, and surface composition in HSA solution • Comparison between HSA and BSA as protein simulators in PBS solutions • The most ions released from 316L and Co–28Cr–6Mo were Fe and Co. • The oxide composition of 316L contained Fe{sub 2}O{sub 3}, MoO{sub 2}, and MoO{sub 3} in only HSA solutions.

  8. Mechanisms of hardening, wear and corrosion improvement of 316 L stainless steel by low energy high current pulsed electron beam surface treatment

    Energy Technology Data Exchange (ETDEWEB)

    Zou, J.X. [Laboratoire d' Etude des Textures et Applications aux Materiaux (LETAM, UMR-CNRS 7078), Universite Paul Verlaine - Metz, Ile du Saulcy, 57045 Metz (France); Shanghai Engineering Research Center of Mg Materials and Applications and School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240 (China); Key Laboratory of Materials Modification by Laser, Electron and Ion beams, Dalian University of Technology, Dalian 116024 (China); Zhang, K.M. [School of Materials Engineering, Shanghai University of Engineering Science, Shanghai 201620 (China); Hao, S.Z.; Dong, C. [Key Laboratory of Materials Modification by Laser, Electron and Ion beams, Dalian University of Technology, Dalian 116024 (China); Grosdidier, T., E-mail: thierry.grosdidier@univ-metz.f [Laboratoire d' Etude des Textures et Applications aux Materiaux (LETAM, UMR-CNRS 7078), Universite Paul Verlaine - Metz, Ile du Saulcy, 57045 Metz (France); Key Laboratory of Materials Modification by Laser, Electron and Ion beams, Dalian University of Technology, Dalian 116024 (China)

    2010-12-01

    The mechanisms of corrosion and wear improvements by low energy high current pulsed electron beam (LEHCPEB) have been investigated for an AISI 316 L steel. Selective purification followed by epitaxial growth occurred in the top surface melted layer (2-3 {mu}m thick) that was softened by tensile stresses and, to a much lower extent, by lower efficiency of MnS precipitation hardening. Electrochemical impedance spectroscopy and potentiodynamic polarization analyses used to model the corrosion behavior revealed that, while craters initiated at MnS inclusions initially served as pitting sites, the resistance was increased by 3 orders of magnitude after sufficient number of pulses by the formation of a homogeneous covering layer. The wear resistance was effectively improved by sub-surface (over 100 {mu}m) work hardening associated with the combine effect of the quasi-static thermal stress and the thermal stress waves. The overall results demonstrate the potential of the LEHCPEB technique for improving concomitantly the corrosion and wear performances of metallic materials.

  9. Laser Welding Of Thin Sheet Of AISI 301 Stainless Steel

    Science.gov (United States)

    Vilar, R.; Miranda, R. M.

    1989-01-01

    Preliminary results of an investigation on laser welding of AISI 301 stainless steel thin sheet are presented. Welds were made with a CO2 continuous wave laser, varying power density and welding speed. The welds were studied by optical and electron scanning microscopy, X-ray diffraction and hardness tests. Experimental results show that under appropriate conditions, sound welds are obtained, with a negligeable heat affected zoneanda fine microstructure in the fusion zone. The fusion zone shows a cellular - dendritic microstructure, with austenite and ferrite as the major constituents. Ferrite, whose content is 5 to 7%, is predominantly intradendritic with both vermicular and acicular morphologies. However some interdendritic ferrite may also be present. The characteristics of the structure suggest that the solidification mode of AISI 301 stainless steel is essentially ferritic.

  10. RESEARCH AND DEVELOPMENT OF SURFACE MODIFICATION OF MEDICAL 316 L STAINLESS STEEL%医用316 L不锈钢表面改性研究及发展

    Institute of Scientific and Technical Information of China (English)

    徐林; 巴德纯; 王庆; 姜媛媛

    2014-01-01

    316L不锈钢因其优良的性能和低廉的价格广泛应用于临床及医疗领域。通过分析医用316L不锈钢目前存在的主要问题及发展状况,对医用316L不锈钢近年来表面改性的新方法和新成果进行了较为详细的介绍,表明表面改性技术是解决临床应用问题的良好途径,为医用316L不锈钢的医学应用提供了新的发展机遇。%316L stainless steel is widely used in clinical and medical fields owing to its excellent properties and low price. The major existing problems and research progresses of medical 316L stainless steel are analyzed. The new methods and research achievement of surface modification for medical 316L stainless steel in recent years are described in detail. It indicates that surface modification is an effective way to solve clinical application problems. The new opportunities for medi-cal 316L stainless steel in medical applications are provided.

  11. Penetration treatment of plasma spray SUS316L stainless steel coatings by molten MnO–SiO{sub 2} oxides

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jin, E-mail: wangjinustb@gmail.com [Graduate School of Life Science and Systems Engineering, Kyushu Institute of Technology, Kitakyusyu (Japan); Shinozaki, Nobuya [Graduate School of Life Science and Systems Engineering, Kyushu Institute of Technology, Kitakyusyu (Japan); Zeng, Zhensu; Sakoda, Nobuaki [Kurashiki Boring Kiko Co., Ltd., Okayama (Japan); Fukami, Naotaka [Taiko Refractories Co., Ltd., Fukuoka (Japan)

    2015-01-15

    Highlights: • MnO–SiO{sub 2} oxides could penetrate into stainless steel coating with in 5 min. • MnO–SiO{sub 2} oxides infiltrated to interface (300 μm) when treatment extended to 20 min. • Spinel-type MnCr{sub 2}O{sub 4} crystal particles emerged in MnO–SiO{sub 2} oxides after penetration. - Abstract: A study of the penetration treatment of plasma sprayed SUS316L stainless steel coatings by molten MnO–SiO{sub 2} oxides with near-eutectic composition was performed. The penetration treatment was introduced at 1353 K for 5, 20, and 45 min, and the effectiveness of the penetration and the underlying mechanisms of interfacial reactions are discussed on the basis of structural observation (EPMA), high-temperature wetting measurements and further supported by a thermodynamic calculation and analysis. The results indicated that at 1353 K, the MnO–SiO{sub 2} oxides could infiltrate into the stainless steel coating within a depth of approximately 100 μm within 5 min due to the very good wettability of the stainless steel coating by molten MnO–SiO{sub 2} oxides. The oxide could further penetrate to the coating/substrate interface when the treatment was extended to 20 min. During the penetration into the coating, a reaction between the MnO–SiO{sub 2} oxides and adjacent stainless steel particles occurred, which produced MnCr{sub 2}O{sub 4} crystalline particles characterized by a spinel structure. As a result, a variation of the MnO–SiO{sub 2} oxides composition was observed.

  12. In-vitro bioactivity, biocorrosion and antibacterial activity of silicon integrated hydroxyapatite/chitosan composite coating on 316 L stainless steel implants

    Energy Technology Data Exchange (ETDEWEB)

    Sutha, S.; Kavitha, K.; Karunakaran, G.; Rajendran, V., E-mail: veerajendran@gmail.com

    2013-10-15

    A simple and effective ultrasonication method was applied for the preparation of 0, 0.4, 0.8, 1.0 and 1.6 wt% silicon substituted hydroxyapatite (HAp) (SH). The Ca/P ratio of the synthesised SH nanoparticles were in the range of 1.58–1.70. Morphological changes were noticed in HAp with respect to the amount of Si from 0 to 1.6 wt%. The morphology of the particles changed from spherical shape to rod-like morphology with respect to the amount of Si which was confirmed using transmission electron microscopy. X-ray diffraction studies confirm the formation of phase pure SH nanoparticles without any secondary phase. Chitosan (CTS) blended SH nanocomposites coating on surgical grade 316 L stainless steel (316 L SS) implant was made by spin coating technique. The surface of the coated implant was characterised using scanning electron microscopy which confirms the uniform coating without cracks and pores. The increased corrosion resistance of the 1.6 wt% of SH/CTS-coated SS implant in the simulated body fluid (SBF) indicates the long-term biostability of SH composite-coated ceramics in vitro than the 0 wt% SH/CTS. The testing of SH/CTS nanocomposites with gram-positive and gram-negative bacterial strains confirms that the antibacterial ability improves with the higher substitution of Si. In addition, formation of bone-like apatite layer on the SH/CTS-coated implant in SBF was studied through SEM analysis and it confirms the ability to increase the HAp formation on the surface of 1.0 wt% SH/CTS-coated 316 L SS implant. Highlights: • Hydroxyapatite particles are prepared with various silicon concentration • Prepared composites are blended with chitosan and coated on the implant • Corrosion resistance in simulated body fluid improves its stability • Increase in silicon concentration improves the antibacterial activity • Coated plate exhibit high in-vitro bioactivity in simulated body fluid.

  13. Characterization of Stainless Steel 316L Feedstock for Metal Injection Molding (MIM) Using Waste Polystyrene and Palm Kernel Oil Binder System

    Science.gov (United States)

    Asmawi, R.; Ibrahim, M. H. I.; Amin, A. M.; Mustafa, N.

    2016-11-01

    This paper presents the homogeneity characterisation of MIM feedstock consisting Stainless steel alloy (316 L) powder mix with binder 60wt% of waste polystyrene and 40wt% palm kernel oil. It is one of a critical step that must be conducted in MIM process in order to have a feedstock that is homogeneous and moldable. Water atomised Stainless Steel powder was mixed with the newly developed binder system in a Brabender Plastograph EC rotary mixer. Several tests were performed to assess the homogeneity of the feedstock that was produced at 60 vol % powder loading . The 60 vol.% was chosen because the Critical Powder Volume Concentration (CPVC) of the Powder was found to be 64.8 vol.%. The tests conducted were feedstock density, binder burn-out, rheology and SEM morphology observation. Rheological results exhibited pseudoplastic or shear thinning flow behavior, where its viscosity decreased with increasing shear rate. The feedstock viscosity also decreased with increasing temperature and was found to be suitable for molding. From all the tests conducted, it was found that the feedstock shows good homogeneity and suitable for subsequent processes in MIM.

  14. Electrophoretic Deposition of Chitosan/h-BN and Chitosan/h-BN/TiO2 Composite Coatings on Stainless Steel (316L Substrates

    Directory of Open Access Journals (Sweden)

    Namir S. Raddaha

    2014-03-01

    Full Text Available This article presents the results of an experimental investigation designed to deposit chitosan/hexagonal boron nitride (h-BN and chitosan/h-BN/titania (TiO2 composites on SS316L substrates using electrophoretic deposition (EPD for potential antibacterial applications. The influence of EPD parameters (voltage and deposition time and relative concentrations of chitosan, h-BN and TiO2 in suspension on deposition yield was studied. The composition and structure of deposited coatings were investigated by FTIR, XRD and SEM. It was observed that h-BN and TiO2 particles were dispersed in the chitosan matrix through simultaneous deposition. The adhesion between the electrophoretic coatings and the stainless steel substrates was tested by using tape test technique, and the results showed that the adhesion strength corresponded to 3B and 4B classes. Corrosion resistance was evaluated by electrochemical polarization curves, indicating enhanced corrosion resistance of the chitosan/h-BN/TiO2 and chitosan/h-BN coatings compared to the bare stainless steel substrate. In order to investigate the in-vitro inorganic bioactivity, coatings were immersed in simulated body fluid (SBF for 28 days. FTIR and XRD results showed no formation of hydroxyapatite on the surface of chitosan/h-BN/TiO2 and chitosan/h-BN coatings, which are therefore non bioactive but potentially useful as antibacterial coatings.

  15. Ion release and surface oxide composition of AISI 316L, Co-28Cr-6Mo, and Ti-6Al-4V alloys immersed in human serum albumin solutions.

    Science.gov (United States)

    Karimi, Shima; Alfantazi, Akram M

    2014-07-01

    The long-term weight loss, ion release, and surface composition of 316L, Co-28Cr-6Mo and Ti-6Al-4V alloys were investigated in a simulated body environment. The samples were immersed in phosphate-buffered saline (PBS) solutions with various human serum albumin (HSA) concentrations for 8, 14, and 22 weeks. The specimens initially lost weight up to 14 weeks and then slightly gained weight. The analysis of the released ions was performed by induced coupled plasma-optical emission spectrometer (ICP-OES). The results revealed that the precipitation of the dissolved Fe and Co could cause the weight gain of the 316L and Co-28Cr-6Mo alloys. The surface chemistry of the specimens was determined by X-ray photoelectron spectroscopy (XPS). The XPS analysis of Co-28Cr-6Mo alloy showed that the interaction of Mo with HSA is different from Mo with bovine serum albumin (BSA). This was also observed for Na adsorption into the oxide layer of Ti-6Al-4V alloy in the presence of HSA and BSA.

  16. Improvement of stress corrosion cracking (SCC) resistance by cyclic pre-straining of 316L austenitic stainless steel in an aqueous boiling MgCl{sub 2} solution; Amelioration de la tenue a la corrosion sous contrainte (CSC) de l'acier inoxydable austenitique 316L en solution bouillante de MgCl{sub 2} par application d'une predeformation cyclique

    Energy Technology Data Exchange (ETDEWEB)

    Curiere, I. de; Bayle, B.; Magnin, Th. [Ecole Nationale Superieure des Mines, URA CNRS 1884, 42 - Saint-Etienne (France)

    2000-07-01

    Improving the materials resistance to stress corrosion cracking (SCC) has become a topic of wide interest for theoretical, engineering and financial reasons. The aim of this paper is to propose a process to delay the SCC damage. Recent studies of 316L austenitic stainless steel in boiling MgCl{sub 2} solutions show an improvement in SCC resistance by cyclic pre-straining in low cycle fatigue. This improvement consists of an increase in both strain to failure and crack initiation strain, during Slow Rate Tensile (SSRT) tests in aqueous solution. This paper analyses the effect of pre-fatigue in 316L on its mechanical and electrochemical responses to better understand the delay of SCC damage in boiling MgCl{sub 2}. The explanation for this beneficial effect is related to a modification of both surface electrochemical reactions kinetics and corrosion/plasticity interactions at the crack tip, due to the particular dislocation structure. (authors)

  17. Effects of Ag and Cu ions on the microbial corrosion of 316L stainless steel in the presence of Desulfovibrio sp.

    Science.gov (United States)

    Unsal, Tuba; Ilhan-Sungur, Esra; Arkan, Simge; Cansever, Nurhan

    2016-08-01

    The utilization of Ag and Cu ions to prevent both microbial corrosion and biofilm formation has recently increased. The emphasis of this study lies on the effects of Ag and Cu ions on the microbial corrosion of 316L stainless steel (SS) induced by Desulfovibrio sp. Electrochemical impedance spectroscopy (EIS) and potentiodynamic polarization were used to analyze the corrosion behavior. The biofilm formation, corrosion products and Ag and Cu ions on the surfaces were investigated using scanning electron microscopy (SEM), energy dispersive X-ray spectrometry (EDS) and elemental mapping. Through circuit modeling, EIS results were used to interpret the physicoelectric interactions between the electrode, biofilm and culture interfaces. EIS results indicated that the metabolic activity of Desulfovibrio sp. accelerated the corrosion rate of SS in both conditions with and without ions. However, due to the retardation in the growth of Desulfovibrio sp. in the presence of Ag and Cu ions, significant decrease in corrosion rate was observed in the culture with the ions. In addition, SEM and EIS analyses revealed that the presence of the ions leads to the formation on the SS of a biofilm with different structure and morphology. Elemental analysis with EDS detected mainly sulfide- and phosphorous-based corrosion products on the surfaces.

  18. The effects of cold rolling orientation and water chemistry on stress corrosion cracking behavior of 316L stainless steel in simulated PWR water environments

    Science.gov (United States)

    Chen, Junjie; Lu, Zhanpeng; Xiao, Qian; Ru, Xiangkun; Han, Guangdong; Chen, Zhen; Zhou, Bangxin; Shoji, Tetsuo

    2016-04-01

    Stress corrosion cracking behaviors of one-directionally cold rolled 316L stainless steel specimens in T-L and L-T orientations were investigated in hydrogenated and deaerated PWR primary water environments at 310 °C. Transgranular cracking was observed during the in situ pre-cracking procedure and the crack growth rate was almost not affected by the specimen orientation. Locally intergranular stress corrosion cracks were found on the fracture surfaces of specimens in the hydrogenated PWR water. Extensive intergranular stress corrosion cracks were found on the fracture surfaces of specimens in deaerated PWR water. More extensive cracks were found in specimen T-L orientation with a higher crack growth rate than that in the specimen L-T orientation with a lower crack growth rate. Crack branching phenomenon found in specimen L-T orientation in deaerated PWR water was synergistically affected by the applied stress direction as well as the preferential oxidation path along the elongated grain boundaries, and the latter was dominant.

  19. Drug-eluting coating of ginsenoside Rg1 and Re incorporated poly(lactic-co-glycolic acid) on stainless steel 316L: Physicochemical and drug release analyses.

    Science.gov (United States)

    Miswan, Zulaika; Lukman, Siti Khadijah; Abd Majid, Fadzilah Adibah; Loke, Mun Fai; Saidin, Syafiqah; Hermawan, Hendra

    2016-12-30

    Active ingredients of ginsenoside, Rg1 and Re, are able to inhibit the proliferation of vascular smooth muscle cells and promote the growth of vascular endothelial cells. These capabilities are of interest for developing a novel drug-eluting stent to potentially solve the current problem of late-stent thrombosis and poor endotheliazation. Therefore, this study was aimed to incorporate ginsenoside into degradable coating of poly(lactic-co-glycolic acid) (PLGA). Drug mixture composed of ginseng extract and 10% to 50% of PLGA (xPLGA/g) was coated on electropolished stainless steel 316L substrate by using a dip coating technique. The coating was characterized principally by using attenuated total reflectance-Fourier transform infrared spectroscopy, scanning electron microscopy and contact angle analysis, while the drug release profile of ginsenosides Rg1 and Re was determined by using mass spectrometry at a one month immersion period. Full and homogenous coating coverage with acceptable wettability was found on the 30PLGA/g specimen. All specimens underwent initial burst release dependent on their composition. The 30PLGA/g and 50PLGA/g specimens demonstrated a controlled drug release profile having a combination of diffusion- and swelling-controlled mechanisms of PLGA. The study suggests that the 30PLGA/g coated specimen expresses an optimum composition which is seen as practicable for developing a controlled release drug-eluting stent.

  20. Effect of Ringer's Solution on Wear and Friction of Stainless Steel 316L after Plasma Electrolytic Nitrocarburising at Low Voltages

    Institute of Scientific and Technical Information of China (English)

    N. Afsar Kazerooni; M.E. Bahrololoom; M.H. Shariat; F.Mahzoon; T. Jozaghi

    2011-01-01

    A plasma electrolytic nitrocarburising (PEN/C) process was performed on stainless steel 316L to improve the surface properties for using as medical implants. A bath was optimised to reduce the required voltage to 150 volts. Aqueous urea-based solutions with 10% NH4Cl were prepared with slightly different amounts of Na2CO3 to optimise the electrolyte composition. The surface and the cross-section morphologies were studied by scanning electron microscopy. The microstructure and the chemical composition of samples were investigated by X-ray diffraction (XRD) and energy dispersive X-ray (EDX) techniques. The microstructure of the outer layer of the coatings was found to be a complex oxide containing Cr and Fe. The wear properties of the samples were examined by using a pin on disk wear test with Ringer's solution and were compared with their wear properties in the ambient atmosphere. The Ringe(s solution acted as a lubricant, reducing friction coefficient. Hardness and roughness were also studied. The bath with the composition of 10% NH4CI and 3% Na2CO3 exhibited the best tribological properties. The results showed that the tribological properties of treated samples were improved and the wear mechanism was abrasion of the pin.

  1. Comparison between Palm Oil Derivative and Commercial Thermo-Plastic Binder System on the Properties of the Stainless Steel 316L Sintered Parts

    Science.gov (United States)

    Ibrahim, R.; Azmirruddin, M.; Wei, G. C.; Fong, L. K.; Abdullah, N. I.; Omar, K.; Muhamad, M.; Muhamad, S.

    2010-03-01

    Binder system is one of the most important criteria for the powder injection molding (PIM) process. Failure in the selection of the binder system will affect on the final properties of the sintered parts. The objectives of this studied is to develop a novel binder system based on the local natural resources and environmental friendly binder system from palm oil derivative which is easily available and cheap in our country of Malaysia. The novel binder that has been developed will be replaced the commercial thermo-plastic binder system or as an alternative binder system. The results show that the physical and mechanical properties of the final sintered parts fulfill the Metal Powder Industries Federation (MPIF) standard 35 for PIM parts. The biocompatibility test using cell osteosarcoma (MG63) and vero fibroblastic also shows that the cell was successfully growth on the sintered stainless steel 316L parts indicate that the novel binder was not toxic. Therefore, the novel binder system based on palm oil derivative that has been developed as a binder system fulfills the important criteria for the binder system in PIM process.

  2. Diffusion Brazing of Ti-6Al-4V and Stainless Steel 316L Using AgCuZn Filler Metal

    Directory of Open Access Journals (Sweden)

    R. Soltani Tashi

    2013-09-01

    Full Text Available In the present study, vacuum brazing was applied to join Ti-6Al-4V and stainless steel using AgCuZn filler metal. The bonds were characterized by scanning electron microscopy, energy dispersive spectroscopy and X-ray diffraction analysis. Mechanical strengths of the joints were evaluated by the shear test and microhardness. It has been shown that shear strength decreased with increasing the brazing temperature and time. The wettability of the filler alloy was increased by enhancing the wetting test temperature. By increasing the brazing temperature various intermetallic compounds were formed in the bond area. These intermetallic compounds were mainly a combination of CuTi and Fe-Cu-Ti. The shear test results verified the influence of the bonding temperature on the strength of the joints based on the formation of different intermetallics in the bond zone. The fracture analysis also revealed different fracture footpath and morphology for different brazing temperatures.

  3. Glow Discharge Plasma Nitriding of AISI 304 Stainless Steel

    Institute of Scientific and Technical Information of China (English)

    A.QAYYUM; M.A.NAVEED; S.ZEB; G.MURTAZA; M.ZAKAULLAH

    2007-01-01

    Glow discharge plasma nitriding of AISI 304 austenitic stainless steel has been carried out for different processing time under optimum discharge conditions established by spectroscopic analysis.The treated samples were analysed by X-ray diffraction(XRD)to explore the changes induced in the crystallographic structure.The XRD pattern confirmed the formation of an expanded austenite phase(γN)owing to incorporation of nitrogen as an interstitial solid solution in the iron lattice.A Vickers microhardness tester was used to evaluate the surface hardness as a function of indentation depth(μm).The results showed clear evidence of surface changes with substantial increase in surface hardness.

  4. Comparative study of the native oxide on 316L stainless steel by XPS and ToF-SIMS

    Energy Technology Data Exchange (ETDEWEB)

    Tardio, Sabrina, E-mail: s.tardio@surrey.ac.uk; Abel, Marie-Laure; Castle, James E.; Watts, John F. [Department of Mechanical Engineering Sciences, University of Surrey, Guildford, Surrey GU2 7XH (United Kingdom); Carr, Robert H. [Huntsman PU, Everslaan 45, B-3078 Everberg (Belgium)

    2015-09-15

    The very thin native oxide film on stainless steel, of the order of 2 nm, is known to be readily modified by immersion in aqueous media. In this paper, X-ray photoelectron spectroscopy (XPS) and time of flight secondary ions mass spectrometry are employed to investigate the nature of the air-formed film and modification after water emersion. The film is described in terms of oxide, hydroxide, and water content. The preferential dissolution of iron is shown to occur on immersion. It is shown that a water absorbed layer and a hydroxide layer are present above the oxide-like passive film. The concentrations of water and hydroxide appear to be higher in the case of exposure to water. A secure method for the peak fitting of Fe2p and Cr2p XPS spectra of such films on their metallic substrates is described. The importance of XPS survey spectra is underlined and the feasibility of C{sub 60}{sup +} SIMS depth profiling of a thin oxide layer is shown.

  5. COLD ROLLING ORTHODONTIC WIRES OF AUSTENITIC STAINLESS STEEL AISI 304

    Directory of Open Access Journals (Sweden)

    Rodrigo Santos Messner

    2013-03-01

    Full Text Available Austenitic stainless steels wires are widely used in the final stages of orthodontic treatment. The objective of this paper is to study the process of conformation of rectangular wires from round wires commercial austenitic stainless steel AISI 304 by the process of cold rolling. The wire quality is evaluated by means of dimensional analysis, microhardness measurements, tensile strength and fractographic analysis of the wires subjected to tensile tests. Also a study on the application of finite element method to simulate the process, comparing the force and rolling stress obtained in the rolling is done. The simulation results are consistent with those obtained in the actual process and the rolled wires show ductile fracture, tensile strength and dimensional variations appropriate to orthodontic standards. The fracture morphology shows the model cup-cone type besides the high deformation and hardness inherent in the cold rolling process.

  6. Evaluation of the contact corrosion of the nano structured 316L stainless steel by SMAT process; Comportement en corrosion de contact de l'acier inoxydable 316L nanostructure par procede SMAT

    Energy Technology Data Exchange (ETDEWEB)

    Seeva Durmooa [Laboratoire de Mecanique Roberval, FRE CNRS 2833, Universite de Technologie de Compiegne (France); Faculte d' Ingenierie, Universite de Maurice (Mauritius); Caroline Richarda [Laboratoire de Mecanique Roberval, FRE CNRS 2833, Universite de Technologie de Compiegne (France); Jian Lub [Laboratoire des Systemes Mecaniques et d' Ingenierie Simultanee, FRE CNRS 2719, Universite de Technologie de Troyes (France)

    2005-07-01

    This study was carried out in view to evaluate the efficiency of ultrasonic shot peening (Surface Mechanical Attrition Treatment: SMAT), on the tribological behaviour of 316L due to fretting effects. The amount of samples to be prepared was based on an experimental plan which account the various parameters incur in our fretting test. These experimental conditions were the: load, sliding velocity, stroke length and temperature. As a first experimental outcome, it is noted that the surface roughness plays a determinant role in the friction mechanism, i.e when the roughness of the surface is more and more damaged, the wear debris are located in the cavities area and contribute to increase the friction coefficient significantly. Hence, the treatment time of the samples is directly link to the surface roughness. The optimum time of SMAT was 12 minutes, and gave the best tribological properties results. Added to this fretting test, an induce vibration analysis was carried out to appreciate wear mechanism. (author)

  7. A Comparative Evaluation of the Effect of Low Cycle Fatigue and Creep-Fatigue Interaction on Surface Morphology and Tensile Properties of 316L(N) Stainless Steel

    Science.gov (United States)

    Mariappan, K.; Shankar, Vani; Sandhya, R.; Bhaduri, A. K.; Laha, Kinkar

    2016-04-01

    In the present work, the deformation and damage evolution in 316L(N) stainless steel during low cycle fatigue (LCF) and creep-fatigue interaction (CFI) loadings have been compared by evaluating the residual tensile properties. Towards this, LCF and CFI experiments were carried out at constant strain amplitude of ±0.6 pct, strain rate of 3 × 10-3 s-1 and temperature of 873 K (600 °C). During CFI tests, 30 minutes hold period was introduced at peak tensile strain. Experiments were interrupted up to various levels of fatigue life viz. 5, 10, 30, 50, and 60 pct of the total fatigue life ( N f) under both LCF and CFI conditions. The specimens subjected to interrupted fatigue loadings were subsequently monotonically strained at the same strain rate and temperature up to fracture. Optical and scanning electron microscopy and profilometry were conducted on the untested and tested samples to elucidate the damage evolution during the fatigue cycling under both LCF and CFI conditions. The yield strength (YS) increased sharply with the progress of fatigue damage and attained saturation within 10 pct of N f under LCF condition. On the contrary, under CFI loading condition, the YS continuously increased up to 50 pct of N f, with a sharp increase of YS up to 5 pct of N f followed by a more gradual increase up to 50 pct of N f. The difference in the evolution of remnant tensile properties was correlated with the synergistic effects of the underlying deformation and damage processes such as cyclic hardening/softening, oxidation, and creep. The evolution of tensile properties with prior fatigue damage has been correlated with the change in surface roughness and other surface features estimated by surface replica technique and fractography.

  8. The Tribological Performance of Surface Treated Ti6A14V as Sliding Against Si3N4 Ball and 316L Stainless Steel Cylinder

    Science.gov (United States)

    Kao, W. H.; Su, Y. L.; Horng, J. H.; Huang, H. C.

    2016-12-01

    Closed field unbalanced magnetron sputtering was used to deposit diamond-like carbon (Ti-C:H) coatings on Ti6Al4V alloy and gas nitrided Ti6Al4V alloy. Four different specimens were prepared, namely untreated Ti6Al4V alloy (Ti6Al4V), gas nitrided Ti6Al4V alloy (N-Ti6Al4V), Ti-C:H-coated Ti6Al4V alloy (Ti-C:H/Ti6Al4V) and Ti-C:H-coated gas nitrided Ti6Al4V alloy (Ti-C:H/N-Ti6Al4V). The tribological properties of the four specimens were evaluated using a reciprocating wear tester sliding against a Si3N4 ball (point contact mode) and 316L stainless steel cylinder (line contact mode). The wear tests were performed in a 0.89 wt.% NaCl solution. The results showed that the nitriding treatment increased the surface roughness and hardness of the Ti6Al4V alloy and improved the wear resistance as a result. In addition, the Ti-C:H coating also improved the tribological performance of Ti6Al4V. For example, compared to the untreated Ti6Al4V sample, the Ti-C:H coating reduced the wear depth and friction coefficient by 340 times and 10 times, respectively, in the point contact wear mode, and 151 times and 9 times, respectively, in the line contact wear mode. It is thus inferred that diamond-like carbon coatings are of significant benefit in extending the service life of artificial biomedical implants.

  9. Predicción del desgaste del flanco de la herramienta de corte durante el torneado en seco de alta velocidad para piezas de acero AISI 316L en la industria minera

    Directory of Open Access Journals (Sweden)

    Yusimit K. Zamora-Hernández

    2015-07-01

    Full Text Available Se realizó un estudio experimental sobre la influencia de los parámetros de corte en el torneado del acero inoxidable AISI 316L con insertos recubiertos de TiCN, Al2O3, TiN. Un microscopio electrónico de barrido fue utilizado para medir y analizar el desgaste de las herramientas de corte. Los resultados fueron comparados utilizando el análisis de varianza y el análisis de regresión múltiple para describir la relación entre el desgaste del flanco de las herramientas de corte, el tiempo de maquinado y el avance de corte, obteniéndose las ecuaciones de los modelos ajustados. La investigación demostró el efecto significativo del avance y del tiempo de maquinado en el desgaste del flanco. El inserto de tres capas no sobrepasó el criterio de fin de vida del desgaste, mientras que el inserto de una capa sufrió un desgaste elevado para la mayor velocidad de corte. El desgaste del flanco tuvo mejor comportamiento para el avance de 0,08 mm/rev en todas las velocidades empleadas en este estudio. Los errores medios absolutos no superaron el 15 %.

  10. A Study on the Effect of the Boron Potential on the Mechanical Properties of the Borided Layers Obtained by Boron Diffusion at the Surface of AISI 316L Steel

    Directory of Open Access Journals (Sweden)

    E. Hernández-Sánchez

    2014-01-01

    Full Text Available The effect of the boron potential on the thickness and the mechanical properties of borided layers was evaluated. The boron potential was established by means of the available atoms of boron contained in a control volume inside a cylinder. The cylinders were manufactured from AISI 316L steel, and the boriding treatment was performed using the powder pack technique at a temperature of 1273 K over an exposure time of 6 h. Four different internal diameters of the cylinders were evaluated (3.17, 4.76, 6.35, and 7.93 mm. The mechanical properties were evaluated using the Berkovich instrumented indentation technique. The results showed a clear influence of the boron potential on the mechanical properties of the layers. The hardness of the layers was stablished in the range of 16.22 to 21.16 GPa. Young’s modulus values were stablished in the range of 255.96 to 341.37 GPa. Also the fracture toughness and brittleness of the layers reflected the influence of the boron potential supplied during the boriding process. Finally, the influence of the boron potential on the constant of parabolic growth (K was also established as a function of the inner diameter of the cylinders.

  11. Corrosion Behavior of 316L Stainless Steel in High Chloride Ion Ethylene Glycol%316L不锈钢在高含氯离子乙二醇中的腐蚀行为

    Institute of Scientific and Technical Information of China (English)

    邵暘洋; 王斌; 周冬梅

    2011-01-01

    The effect of the temperature and Cl- concentration on the corrosion dynamic behavior of 316L stainless steel using weightlessness method; The intergranular corrosion tendency of 316L was determined. The experimental results shown that the corrosion rate of 316L stainless steel increases with rising of temperature when the Cl~ concentration is 36516 mg/L and Fe3+ concentration is 776 mg/L; When the temperature is over 60 ℃ ,the corrosion rate increases rapidly, and up to maximum 0. 0781 mm/a at 120 ℃; 316L stainless steel has a tendency to intergranular corrosion according to intergranular corrosion standard.%采用失重法实验研究了温度、Cl-浓度对316L不锈钢腐蚀动力学行为的影响;实验判别了316L的晶间腐蚀倾向.结果表明:在C1-质量浓度为36 516 mg/L,Fe3+质量浓度为776 mg/L的情况下,316L的腐蚀速率随温度的升高而增大,温度超出60℃时腐蚀速率迅速增大,120℃时腐蚀速率达到最大值0.0781 mm/a;根据晶间腐蚀标准可知,316L不锈钢在氯离子含量较高的乙二醇溶液中具有晶间腐蚀倾向.

  12. Uptake of nickel from 316L stainless steel into contacting osteoblastic cells and metal ion interference with BMP-2-induced alkaline phosphatase.

    Science.gov (United States)

    Mölders, Martina; Felix, Joachim; Bingmann, Dieter; Hirner, Alfred; Wiemann, Martin

    2007-11-01

    Bone cells contacting nickel (Ni)-containing implant materials may be affected by Ni species via disturbed signaling pathways involved in bone cell development. Here we analyze effects of the Ni-containing steel 316L and major metal constituents thereof on bone morphogenetic protein-2 (BMP-2)-induced alkaline phosphatase (ALP) of MC3T3-E1 cells. While cells grew normally on 316L, cellular Ni content increased 10-fold vs. control within 4 days. With respect to the major components of 316L, Ni2+ (3-50 microM) was most inhibitory to BMP-2-induced ALP, whereas even 50 microM Fe3+, Cr3+, Mo5+, or Mn2+ had no such effect. In line with this, BMP-2-induced ALP was significantly reduced in cells on 316L. This effect was not prevented by the metal ion chelator diethylenetriaminepentaacetic acid (DTPA). Instead, DTPA abolished the stimulatory effect of BMP-2 on ALP, pointing to chelatable metal ions involved. Zn2+, as one possible candidate, antagonized the Ni2+ inhibition of BMP-2-induced ALP in both MC3T3-E1 and human bone marrow stromal cells. Results show that cells contacting 316L steel are exposed to increased concentrations of Ni which suffice to impair BMP-2-induced ALP activity. Zn2+, as a competitor of this inhibition, may help to restore normal osteoblastic function and bone development under these conditions.

  13. Investigation of Machinability Characteristics of AISI 316Ti Stainless Steel

    Directory of Open Access Journals (Sweden)

    Yunus Kayır

    2012-01-01

    Full Text Available In this study, many experiments of machinability were carried out on universal turning lathe. The cutting forces that occur during machining of workpieces were measured. A standard dynamometer was used to measure cutting forces. The Dynamometer were assembled on the lathe efficiently. An apart were designed and machined to assembly the dynamometer. Moreover, AISI 316Ti stainless steel parts were turned by carbide cutting tools coated with TiAlN components. Effects of cutting tools with different radius on cutting forces and surface roughness were investigated by using different cutting parameters. Moreover, machined parts' surface roughness was controlled. The experimental results showed that cutting forces increased with the increasing federate, but the surface roughness decreased with increasing the radius of cutting edge.

  14. The Study of Plasma Nitriding of AISI304 Stainless Steel

    Institute of Scientific and Technical Information of China (English)

    WANG Liang; JI Shi-jun; GAO Yu-zhou; SUN Jun-cai

    2004-01-01

    This paper presents results on the plasma nitriding of AISI 304 stainless steel at different temperatures in NH 3 gas. The working pressure was 100~200 Pa and the discharge voltage was 700~800V. The phase of nitrided layer formed on the surface was confirmed by X-ray diffraction. The hardness of the samples was measured by using a Vickers microhardness tester with the load of 50g. After nitriding at about 400 ℃ for two hours a nitrided layer consisting of single γN phase with thickness of 5μm was obtained. Microhardness measurements showed significant increase in the hardness from 240 HV (for untreated samples) up to 950 HV (for nitrided samples at temperature of 420℃). The phase composition, the thickness, the microstructure and the surface topography of the nitrided layer as well as its properties depend essentially on the process parameters.

  15. Tensile and Impact Properties of Shielded Metal Arc Welded AISI 409M Ferritic Stainless Steel Joints

    Institute of Scientific and Technical Information of China (English)

    K.Shanmugam; A.K.Lakshminarayanan; V.Balasubramanian

    2009-01-01

    The present study is concerned with the effect of filler metals such as austenitic stainless steel, ferritic stainless steel and duplex stainless steel on tensile and impact properties of the ferritic stainless steel conforming to AISI 409M grade. Rolled plates of 4 mm thickness were used as the base material for preparing single pass butt welded joints. Tensile and impact properties, microhardness, microstructure and fracture surface morphology of the joints fabricated by austenitic stainless steel, ferritic stainless steel and duplex stainless steel filler metals were evaluated and the results were reported. From this investigation, it is found that the joints fabricated by duplex stainless steel filler metal showed higher tensile strength and hardness compared to the joints fabricated by austenitic and ferritic stainless steel filler metals. Joints fabricated by austenitic stainless steel filler metal exhibited higher ductility and impact toughness compared with the joints fabricated by ferritic stainless steel and duplex stainless steel filler metals.

  16. Fine structure analysis of biocompatible ceramic materials based hydroxyapatite and metallic biomaterials 316L

    Energy Technology Data Exchange (ETDEWEB)

    Anghelina, F.V.; Ungureanu, D.N.; Bratu, V. [Faculty of Materials Engineering and Mechanics, Valahia University of Targoviste, 18-24 Unirii Bd., 130082 (Romania); Popescu, I.N., E-mail: pinicoleta24@yahoo.com [Faculty of Materials Engineering and Mechanics, Valahia University of Targoviste, 18-24 Unirii Bd., 130082 (Romania); Rusanescu, C.O. [Politehnica University, 060042 Bucharest (Romania)

    2013-11-15

    The aim of this paper was to obtain and characterize (surface morphology and fine structure) two types of materials: Ca{sub 10}(PO{sub 4}){sub 6}(OH){sub 2} hydroxyapatite powder (HAp) as biocompatible ceramic materials and AISI 316L austenitic stainless steels as metallic biomaterials, which are the components of the metal–ceramic composites used for medical implants in reconstructive surgery and prosthetic treatment. The HAp was synthesized by coprecipitation method, heat treated at 200 °C, 800 °C and 1200 °C for 4 h, analyzed by X-ray diffraction (XRD) and scanning electron microscope (SEM). The stainless steel 316L type was made by casting, annealing and machined with a low speed (100 mm/s) in order to obtain a smooth surface and after that has been studied from residual stresses point of view in three polishing regimes conditions: at low speed polishing (150 rpm), at high speed polishing (1500 rpm) and high speed-vibration contact polishing (1500 rpm) using wide angle X-ray diffractions (WAXD). The chemical compositions of AISI 316 steel samples were measured using a Foundry Master Spectrometer equipped with CCD detector for spectral lines and the sparking spots of AISI 316L samples were analyzed using SEM. By XRD the phases of HAp powders have been identified and also the degree of crystallinity and average size of crystallites, and with SEM, we studied the morphology of the HAp. It has been found from XRD analysis that we obtained HAp with a high degree of crystallinity at 800 °C and 1200 °C, no presence of impurity and from SEM analysis we noticed the influence of heat treatment on the ceramic particles morphology. From the study of residual stress profiles of 316L samples were observed that it differs substantially for different machining regimes and from the SEM analysis of sparking spots we revealed the rough surfaces of stainless steel rods necessary for a better adhesion of HAp on it.

  17. Electrochemical properties of the 304 and 316L stainless steel in different sodium bicarbonate solution%基于碳酸氢钠溶液的304与316L不锈钢电化学试验研究

    Institute of Scientific and Technical Information of China (English)

    俞树荣; 陈科丰

    2013-01-01

    采用电化学噪声、动电位极化和电容测量方法研究了304、316L不锈钢在不同NaHCO3溶液中的电化学行为及生成钝化膜的半导体性质.在NaHCO3溶液中,304、316L不锈钢存在明显相近的钝化区间;点蚀电位、零电流电位随着NaHCO3浓度的增大而减小.在0.5V电位形成钝化膜的Mott-Schottky曲线表明,304、316L不锈钢在NaHCO3溶液中生成的钝化膜为双层结构,具有相近的成膜特性.但随着NaHCO3溶液浓度变化所生成钝化膜的性质也不同,304不锈钢形成的表面膜稳定性稍好于316L.%Tha methods of electrochemical noise,potentiodynamic polarization and capacitance measurement have been employed to explore the electrochemical properties of the 304 and 316L stainless steel in different sodium bicarbonate solution and the semiconductor properties of passive formation.The 304 and 316L stainless steel hold an approximate passive area in the NaHCO3 solution.The pitting electric potential and the zero current electric potential decline with the increase of the NaHCO3 concentration.The passive Mott-Schottky curve in 0.5v showed that the passive films of the 304 and 306L stainless steel formed in the NaHCO3 solution are double-layer,both of which had the similar films forming characteristics.However,the passive film properties changed with the different NaHCO3 concentration.Furthermore,the surface film formed on 304 stainless steel exhibits a little better stability than that of 316L.

  18. Effect of Post-Weld Heat Treatment on Mechanical and Electrochemical Properties of Gas Metal Arc-Welded 316L (X2CrNiMo 17-13-2) Stainless Steel

    Science.gov (United States)

    Muhammad, F.; Ahmad, A.; Farooq, A.; Haider, W.

    2016-10-01

    In the present research work, corrosion behavior of post-weld heat-treated (PWHT) AISI 316L (X2CrNiMo 17-13-2) specimens joined by gas metal arc welding is compared with as-welded samples by using potentiodynamic polarization technique. Welded samples were PWHT at 1323 K for 480 s and quenched. Mechanical properties, corrosion behavior and microstructures of as-welded and PWHT specimens were investigated. Microstructural studies have shown grain size refinement after PWHT. Ultimate tensile strength and yield strength were found maximum for PWHT samples. Bend test have shown that PWHT imparted ductility in welded sample. Fractographic analysis has evidenced ductile behavior for samples. Potentiodynamic polarization test was carried out in a solution composed of 1 M H2SO4 and 1 N NaCl. Corrosion rate of weld region was 127.6 mpy, but after PWHT, it was decreased to 13.12 mpy.

  19. Study on tempering behaviour of AISI 410 stainless steel

    Energy Technology Data Exchange (ETDEWEB)

    Chakraborty, Gopa, E-mail: gopa_mjs@igcar.gov.in [Metallurgy & Materials Group, Indira Gandhi Center for Atomic Research, Kalpakkam 603102 (India); Das, C.R.; Albert, S.K.; Bhaduri, A.K.; Thomas Paul, V. [Metallurgy & Materials Group, Indira Gandhi Center for Atomic Research, Kalpakkam 603102 (India); Panneerselvam, G. [Chemistry Group, Indira Gandhi Center for Atomic Research, Kalpakkam 603102 (India); Dasgupta, Arup [Metallurgy & Materials Group, Indira Gandhi Center for Atomic Research, Kalpakkam 603102 (India)

    2015-02-15

    Martensitic stainless steels find extensive applications due to their optimum combination of strength, hardness and wear-resistance in tempered condition. However, this class of steels is susceptible to embrittlement during tempering if it is carried out in a specific temperature range resulting in significant reduction in toughness. Embrittlement of as-normalised AISI 410 martensitic stainless steel, subjected to tempering treatment in the temperature range of 673–923 K was studied using Charpy impact tests followed by metallurgical investigations using field emission scanning electron and transmission electron microscopes. Carbides precipitated during tempering were extracted by electrochemical dissolution of the matrix and identified by X-ray diffraction. Studies indicated that temper embrittlement is highest when the steel is tempered at 823 K. Mostly iron rich carbides are present in the steel subjected to tempering at low temperatures of around 723 K, whereas chromium rich carbides (M{sub 23}C{sub 6}) dominate precipitation at high temperature tempering. The range 773–823 K is the transition temperature range for the precipitates, with both Fe{sub 2}C and M{sub 23}C{sub 6} types of carbides coexisting in the material. The nucleation of Fe{sub 2}C within the martensite lath, during low temperature tempering, has a definite role in the embrittlement of this steel. Embrittlement is not observed at high temperature tempering because of precipitation of M{sub 23}C{sub 6} carbides, instead of Fe{sub 2}C, preferentially along the lath and prior austenite boundaries. Segregation of S and P, which is widely reported as one of the causes for temper embrittlement, could not be detected in the material even through Auger electron spectroscopy studies. - Highlights: • Tempering behaviour of AISI 410 steel is studied within 673–923 K temperature range. • Temperature regime of maximum embrittlement is identified as 773–848 K. • Results show that type of

  20. Corrosion Properties of Laser Welded Stainless Steel

    DEFF Research Database (Denmark)

    Weldingh, Jakob; Olsen, Flemmming Ove

    1997-01-01

    In this paper the corrosion properties of laser welded AISI 316L stainless steel are examined. A number of different welds has been performed to test the influence of the weld parameters of the resulting corrosion properties. It has been chosen to use the potential independent critical pitting...

  1. Corrosion Inhibition Performance of Composite Dopamine/BSA Film on Medical 316 L Stainless Steel Surface%医用316 L不锈钢表面多巴胺/BSA复合膜缓蚀性能研究

    Institute of Scientific and Technical Information of China (English)

    陈玉林; 屈钧娥; 王海人; 曹志勇

    2015-01-01

    ABSTRACT:Objective To study the corrosion inhibition performance of composite dopamine ( DP )/bovine serum albumin (BSA) film on the medical 316L stainless steel surface. Methods The dopamine/BSA composite self-assembled bilayer film was prepared by soaking method on the surface of 316L stainless steel (316L SS) by using DP as the bridge layer. The effect of BSA mass concentration on the adsorption behavior and the corrosion inhibition performance of the bilayer film was studied by potentiody-namic scanning, electrochemical impedance spectroscopy ( EIS) , scanning electron microscopy ( SEM) and energy dispersive X-ray detection ( EDX) . Results The composite self-assembled bilayer film showed corrosion inhibition effect in the appropriate con-dition. Too high and too low BSA mass concentrations were both unfavorable for the corrosion inhibition performance of the film. The optimum corrosion inhibition efficiency for 316L SS in physiological saline environment was obtained at the BSA mass concen-tration of 40 g/L, and the corrosion inhibition efficiency increased form 62. 4% of the single DP film to 83. 9% of the DP/BSA bi-layer film. Conclusion The results show that DP molecules successfully graft BSA onto the surface of 316L stainless steel and the adsorption capacity is great improved compared with the single BSA film. It shows that the modified 316L SS surface with good cor-rosion resistance and biocompatibility can be obtained by using dopamine as the adhesive layer to graft BSA onto the substrate.%目的:研究医用316 L不锈钢表面组装多巴胺/牛血清白蛋白分子( BSA )复合膜的缓蚀性能。方法采用浸泡法在医用316 L不锈钢表面制备以多巴胺自组装膜为桥接层的多巴胺/BSA复合双层自组装膜,通过动电位扫描、交流阻抗测试,SEM,EDX等手段分析BSA组装液质量浓度对复合双层自组装膜吸附行为及耐蚀性能的影响。结果在合适的自组装条件下可获得具有缓蚀效果的

  2. Composition and corrosion resistance of palladium film on 316L stainless steel by brush plating%316L不锈钢上电刷镀钯膜的组成与耐蚀性

    Institute of Scientific and Technical Information of China (English)

    唐鋆磊; 左禹; 唐聿明; 熊金平

    2012-01-01

    利用电刷镀工艺在316L不锈钢上制备了结合力良好的钯膜.使用扫描电子显微镜、X射线能谱、X射线光电子能谱(XPS)、质量损失实验和电化学测试研究了膜层的性能.结果表明,电刷镀钯膜主要是由钯元素构成的;XPS分析表明,膜层中的钯为金属态.电刷镀钯后的不锈钢试样在沸腾的20%硫酸溶液和含0.005 mol/L溴离子的甲酸和乙酸混合溶液中均显示了非常好的耐蚀性能.镀钯试样的腐蚀速率比不锈钢试样的下降了2个数量级.%Palladium films with good adhesive strength were deposited on 316L stainless steel by brush plating.Scanning electronic microscopy,energy dispersive X-ray spectroscopy,X-ray photoelectron spectroscopy (XPS),mass loss tests and electrochemical methods were used to study the properties of the films.The brush plated palladium film mainly consisted of palladium.XPS analysis indicated that palladium was present in the films as metal state.The palladium plated stainless steel samples showed excellent corrosion resistance in boiling 20% H2SO4 solution and boiling acetic/formic acids with 0.005 mol/L Br ions added.The corrosion rates of the palladium plated 316L stainless steel samples were about two orders of magnitude lower than those of the original 316L stainless steel samples.This method provides a possibility to prepare protective palladium films on stainless steel facilities with large areas in industrial sites.

  3. Study on compressed thermal deformation behavior and critical damage value of stainless steel 316 L%316 L不锈钢压缩热变形行为及临界损伤值研究

    Institute of Scientific and Technical Information of China (English)

    刘光辉; 刘华; 王伟钦; 张义帅

    2016-01-01

    The mecheanical properties of materials in Deform-3D material library are quite different from that in actual production. A big error will occur when the mechanical properties were applied directly to the simulation. According to the experimental data, simulation was realized, the results would be more accurate and closer to production. For stainless steel 316L, the compress test at high temperature was carried out by Gleeble-1500D simulation testing machine. The influences of temperature and strain rate on the mechanical properties of stainless steel 316L at high temperature were analyzed. The thermal compression process of stainless steel 316L was simulated by the me-chanical properties data in material library and the experimental data respectively. Under the two cases, the stroke-load curves and stress distributions were analyzed, and the critical damage values of stainless steel 316L were analyzed according to the experimental data. The results show that the thermal deformation resistance decreases with the increase of deformation temperature at a constant of strain rate, and the deformation resistance increases with the increase of strain rate at a constant of deformation temperature. Furthermore, the critical damage value of stainless steel 316L with strain rate of 0. 25 s-1 is within the range of 0. 1604-0. 2369.%Deform-3D材料库中材料的力学性能与实际生产差别较大,直接利用其性能参数进行模拟,误差较大。利用实验数据进行模拟,可以使模拟结果更加准确和接近生产。采用Gleeble-1500D热模拟实验机对316L不锈钢进行高温压缩实验,分析了温度和应变速率对316L不锈钢高温力学性能的影响。并分别利用材料库中316L不锈钢力学性能数据和实验数据进行了压缩热变形模拟,分析了两种情况下的行程-载荷曲线和应力分布云图,并根据实验数据的模拟结果分析了316L不锈钢的临界损伤值。结果表明:应变速率一定时,热变

  4. Deformation induced martensite in AISI 316 stainless steel

    Directory of Open Access Journals (Sweden)

    Solomon, N.

    2010-04-01

    Full Text Available The forming process leads to a considerable differentiation of the strain field within the billet, and finally causes the non-uniform distribution of the total strain, microstrusture and properties of the material over the product cross-section. This paper focus on the influence of stress states on the deformation-induced a’ martensitic transformation in AISI Type 316 austenitic stainless steel. The formation of deformation-induced martensite is related to the austenite (g instability at temperatures close or below room temperature. The structural transformation susceptibility is correlated to the stacking fault energy (SFE, which is a function not only of the chemical composition, but also of the testing temperature. Austenitic stainless steels possess high plasticity and can be easily cold formed. However, during cold processing the hardening phenomena always occurs. Nevertheless, the deformation-induced martensite transformation may enhance the rate of work-hardening and it may or may not be in favour of further material processing. Due to their high corrosion resistance and versatile mechanical properties the austenitic stainless steels are used in pressing of heat exchanger plates. However, this corrosion resistance is influenced by the amount of martensite formed during processing. In order to establish the links between total plastic strain, and martensitic transformation, the experimental tests were followed by numerical simulation.

    El proceso de conformación da a lugar a una considerable diferenciación del campo de tensiones dentro de una barra de extrusión y, finalmente, causa una distribución no uniforme de la tensión total, la microestructura y propiedades del material sobre el corte transversal. En este trabajo se estudia la influencia de los estados de tensión sobre la transformación martensítica inducida por deformación en un acero inoxidable austenítico tipo AISI 316. La formación de martensita inducida por

  5. Electro-chemical Corrosion Property of Nuclear-grade 316L Stainless Steel in Zn-containing Water Environment%加Zn水环境中核级316L不锈钢的电化学腐蚀性能分析

    Institute of Scientific and Technical Information of China (English)

    朱宪龙

    2014-01-01

    The effect of the temperature on the electro-chemical corrosion property of nuclear-grade 316L stainless steel (316L SS) in the Zn-containing water environment was investigated by polarization curves and in-situ impedance spectroscopy (EIS).The results show that the protectiveness of the 316L SS oxide film becomes weak with the increase of the temperature.The surface oxide film changes from the single layer to bilayer when the temperature increases,and the Cr-rich oxide layer suppresses the oxidation of the matrix.The growth mechanism of 316L SS is unchanged in Zn-containing water environment,but the corrosion resistance increases.%通过极化曲线和原位阻抗谱(EIS)研究了加Zn水环境中核级316L不锈钢(316L SS)电化学腐蚀性能受温度的影响.结果表明,316L SS氧化膜的保护性随温度的升高而变弱.当温度升高时,其表面的氧化膜从单层变为双层,其中阻挡基体氧化的主要为富Cr氧化层.在加Zn水环境中,316L SS的生长机制虽然不变,但耐腐蚀性会增强.

  6. Effect of Phytic Acid on Corrosion Resistance of 316L Stainless Steel in Salt Water%植酸对咸水介质中316L不锈钢耐蚀性的影响

    Institute of Scientific and Technical Information of China (English)

    张镇川; 陈友媛; 宋芳; 常钦鹏; 彭涛

    2016-01-01

    滨海区地源热泵中材料耐腐蚀性研究是有效开展利用新能源的基础,具有重要意义.采用动电位极化扫描和电化学阻抗谱方法研究了不同植酸组装浓度和组装时间对316L不锈钢在地下咸水介质中耐蚀性的影响,并探讨了植酸与钼酸钠复配形成的自组装膜对316L不锈钢在地下咸水介质中耐蚀性的影响.结果表明:在Cl-质量浓度为10 g/L的NaCl溶液中,随着植酸浓度的增加,316L不锈钢自腐蚀电流密度呈先减小后增大的趋势,自组装膜对316L不锈钢的防护作用先增强后降低;随着自组装时间的延长,植酸自组装膜对316L不锈钢的缓蚀率先上升后下降.在自组装时间为6 h、植酸浓度为10 mmol/L时形成的自组装膜防护效果最好,缓蚀率达到84.17%.向植酸自组装液中添加钼酸钠后,形成的聚合钼酸根通过络合作用和静电作用使316L不锈钢的耐蚀性降低,说明植酸的复配对提高咸水介质中316L不锈钢的耐蚀性是有选择的.这为咸水地区地源热泵系统中316L不锈钢换热器的防护提供了理论指导.%Corrosion resistance of metal materials in ground source heat pump is the basis study for effective u-tilization of new energy sources in the coastal zone,and has important significance.The effects of phytic acid concen-trations,self-assembled times and the addition of sodium molybdate on the corrosion behaviour of 316L stainless steel were investigated by potentiodynamic polarization curves and electrochemical impedance spectroscopy (EIS).The ex-perimental results showed that with the increase of the self-assembled time and the phytic acid concentration,the pro-tective effect was dropped after a rise in the NaCl solution which contains 10 g/L Cl-.The protective effect gained a maximum of about 84.17% while the self-assembled time and the phytic acid concentration were 6 h and 10 mmol/L, respectively.After adding sodium molybdate in the self-assembled solution

  7. Activated flux tungsten inert gas welding of 8 mm-thick AISI 304 austenitic stainless steel

    Institute of Scientific and Technical Information of China (English)

    刘观辉; 刘美华; 易耀勇; 张宇鹏; 罗子艺; 许磊

    2015-01-01

    AISI 304 stainless steel plates were welded with activated flux tungsten inert gas (A-TIG) method by utilizing self-developed activated flux. It is indicated from the experimental results that for 8 mm-thick AISI 304 stainless steel plate, weld joint of full penetration and one-side welding with good weld appearance can be obtained in a single pass without groove preparation by utilizing A-TIG welding. Moreover, activated flux powders do not cause significant effect on the microstructure of TIG weld and the mechanical properties of A-TIG weld joints are also superior to those of C-TIG (conventional TIG) welding.

  8. Modelling of microstructural creep damage in welded joints of 316L stainless steel; Modelisation de l'endommagement a haute temperature dans le metal d'apport des joints soudes d'acier inoxydable austenitique

    Energy Technology Data Exchange (ETDEWEB)

    Bouche, G

    2000-07-01

    Welded joints of 316L stainless steel under service conditions at elevated temperature are known to be preferential sites of creep damage, as compared to the base material. This damage results in the formation of cavities and the development of creep cracks which can lead to a premature failure of welded components. The complex two-phase microstructure of 316L welds was simulated by manually filling a mould with longitudinal deposited weld beads. The moulded material was then aged during 2000 hours at 600 deg. C. High resolution Scanning Electron Microscopy was largely used to examine the microstructure of the simulated material before and after ageing. Smooth and notched creep specimens were cut from the mould and tested at 600 deg. C under various stress levels. A comparison of the lifetime versus nominal stress curves for the base and welded materials shows a greater dependence of the welded material to creep phenomena. Observation and EBSD analysis show that damage is preferentially located along the austenite grain boundaries. The stress and strain fields in the notched specimens were calculated by finite element method. A correlation of this field to the observed damage was made in order to propose a predictive law relating the creep damage to the mechanical conditions applied locally. Further mechanical tests and simulation on CT specimens and mode II tubular specimens allowed validating the model under various multiaxial loading conditions. (author)

  9. Effect of Al Content in Stainless Steel 316L on Microstructures and Mechanical Properties%Al含量对316L不锈钢显微组织和力学性能的影响

    Institute of Scientific and Technical Information of China (English)

    李伟; 秦春霞; 何国国

    2014-01-01

    The effect of Al content on the microstructures,mechanical properties and corrosion resistance of the stainless steel 316L was investigated.The results show that the main existing forms of Al element in the hot-rolled steel 316L are solid solution and second phase Al4C3.The corrosion resistance,yield and tensile strength increase with the increase of the Al content,but the plasticity of the steel decreases.%研究了Al含量对316L不锈钢显微组织、力学性能和抗腐蚀性能的影响.结果表明,Al元素在热轧态316L不锈钢中的主要存在形式是固溶和第二相Al4C3.随着Al含量的增加,316L不锈钢的耐蚀性、屈服强度和抗拉强度升高,但其塑性降低.

  10. 316L不锈钢在硫酸盐还原菌与铁氧化菌溶液中的腐蚀及电化学行为%Corrosion and Electrochemical Behavior of 316L Stainless Steel in Sulfate-reducing and Iron-oxidizing Bacteria Solutions

    Institute of Scientific and Technical Information of China (English)

    胥聪敏; 张耀亨; 程光旭; 朱文胜

    2006-01-01

    Corrosion and electrochemical behavior of 316L stainless steel was investigated in the presence of aerobic iron-oxidizing bacteria (IOB) and anaerobic sulfate-reducing bacteria (SRB) isolated from cooling water systems in an oil refinery using electrochemical measurement, scanning electron microscopy (SEM) and energy dispersive atom X-ray analysis(EDAX). The results show the corrosion potential and pitting potential of 316L stainless steel decrease distinctly in the presence of bacteria, in comparison with those observed in sterile medium under the same exposure time. SEM morphologies have shown that 316L stainless steel reveals no signs of pitting attack in the sterile medium. However, micrometer-scale corrosion pits were observed on 316L stainless steel surface in the presence of bacteria. The presence of SRB leads to higher corrosion rates than IOB. The interactions between the stainless steel surface, abiotic corrosion products, and bacterial cells and their metabolic products increased the corrosion damage degree of the passive film and accelerated pitting propagation.

  11. Adaptability Evaluation of 316L Stainless Steel Based on Pitting Corrosion in Acid Gas Field%基于点蚀的316L不锈钢在酸性气田环境中的适应性评价

    Institute of Scientific and Technical Information of China (English)

    鲍明昱; 任呈强; 郑云萍; 杜磊; 鲜宁; 姜放; 郭小阳

    2016-01-01

    国内外酸性气田的开发使腐蚀环境越来越苛刻,为满足气液混输的工艺要求,发展了耐蚀合金/碳钢的双金属复合管技术。316L不锈钢被广泛用于双金属管的内衬,在含H2 S和CO2环境中腐蚀速率很低,然而在高含Cl-的溶液中,316L不锈钢容易出现点蚀而诱发集输管线失效,为此,就316L不锈钢在酸性气田集输环境中的点蚀进行评述。讨论了影响316 L不锈钢点蚀的材质因素,Mn和Fe的硫化物及Mg、Al、Ca的氧化物等两种夹杂物均能促进钝化膜的溶解而引起点蚀;分析了316L不锈钢点蚀的H2 S、CO2、温度、Cl-浓度和pH值等环境的适应性条件,发现H2 S环境比CO2环境更容易发生点蚀,H2 S和CO2对点蚀发生存在协同机制,温度升高、Cl-浓度增加和酸性介质均会增加316L不锈钢点蚀的敏感性。为进一步优化选材原则,需重点加强环境因素的协同机制、环境适应性的边界条件、点蚀发展的动力学以及新的标准研究。%The corrosion conditions become more and more severe due to the rapid development of acid gas field.In order to meet the requirements of gas-liquid mixed transportation technology,bimetal-lined pipe composed of anti-corrosion alloy and carbon steel has been manufactured.316L stainless steel has been widely used for the liner of the bimetal-lined pipe because of the low corrosion rate in the H2 S and CO2 environments.However,316L stainless steel has potential failure risk,which is attributed to the pitting corrosion in the solution containing Cl-.Therefore, the pitting corrosion of 316L stainless steel in acid gas field is commented.The material factors affecting the pitting corrosion of 316L stainless steel are discussed.Both the sulfide of manganese,iron and the oxide of magnesium,alu-minum,calcium can promote the local dissolution of the passive film and further cause pitting corrosion.The environ-mental adaptability conditions

  12. The adhesion of hot-filament CVD diamond films on AISI type 316 austenitic stainless steel

    NARCIS (Netherlands)

    Buijnsters, J.G.; Shankar, P.; Enckevort, W.J.P. van; Schermer, J.J.; Meulen, J.J. ter

    2004-01-01

    Steel ball indentation and scratch adhesion testing of hot filament chemical vapour deposited diamond films onto AISI type 316 austenitic stainless steel substrates using two different interlayer systems, namely chromium nitride and borided steel, have been investigated. In order to compare the adhe

  13. Comparison of the thermoelastic phenomenon expressions in stainless steels during cyclic loading

    Directory of Open Access Journals (Sweden)

    M. Sapieta

    2017-01-01

    Full Text Available The main purpose of this paper is to compare the thermoelastic stress in specimens of stainless steel. As material specimens we chose stainless steel of AISI 304, AISI 316Ti and AISI 316L types. The specimens were cyclically loaded with three-point bending. The whole process was recorded using an infrared camera. The thermal differences that occurred during the test were evaluated based on the thermoelastic stress equations. Subsequently, stress distributions in the specimens were compared for different types of stainless steel.

  14. Nitriding Process Characterization of Cold Worked AISI 304 and 316 Austenitic Stainless Steels

    Directory of Open Access Journals (Sweden)

    Waldemar Alfredo Monteiro

    2017-01-01

    Full Text Available The nitriding behavior of austenitic stainless steels (AISI 304 and 316 was studied by different cold work degree (0% (after heat treated, 10%, 20%, 30%, and 40% before nitride processing. The microstructure, layer thickness, hardness, and chemical microcomposition were evaluated employing optical microscopy, Vickers hardness, and scanning electron microscopy techniques (WDS microanalysis. The initial cold work (previous plastic deformations in both AISI 304 and 306 austenitic stainless steels does not show special influence in all applied nitriding kinetics (in layer thicknesses. The nitriding processes have formed two layers, one external layer formed by expanded austenite with high nitrogen content, followed by another thinner layer just below formed by expanded austenite with a high presence of carbon (back diffusion. An enhanced diffusion can be observed on AISI 304 steel comparing with AISI 316 steel (a nitrided layer thicker can be noticed in the AISI 304 steel. The mechanical strength of both steels after nitriding processes reveals significant hardness values, almost 1100 HV, on the nitrided layers.

  15. The corrosion behaviour of austenitic and duplex stainless steels in artificial saliva with the addition of fluoride

    Energy Technology Data Exchange (ETDEWEB)

    Kocijan, Aleksandra, E-mail: Aleksandra.Kocijan@imt.s [Institute of Metals and Technology, Lepi pot 11, 1000 Ljubljana (Slovenia); Merl, Darja Kek [Jozef Stefan Institute, Jamova 39, 1000 Ljubljana (Slovenia); Jenko, Monika [Institute of Metals and Technology, Lepi pot 11, 1000 Ljubljana (Slovenia)

    2011-02-15

    Research highlights: The corrosion behaviour of AISI 316L and 2205 DSS in orthodontics. The increased passive range for DSS 2205 compared to AISI 316L in artificial saliva. Higher R{sub p} values of DSS compared to AISI 316L in artificial saliva. The main constituent of the passive layers on DSS at the OCP in saliva was Cr-oxide. DSS 2205 is suitable for orthodontic applications in artificial saliva. - Abstract: The evolution of the passive films on 2205 duplex stainless steel (2205 DSS) and AISI 316L stainless steel in artificial saliva, and with the addition of fluoride, was studied using electrochemical impedance spectroscopy (EIS) and potentiodynamic measurements. The extent of the passive range increased for the 2205 DSS compared to the AISI 316L in both solutions. The formation of the passive film was studied by EIS at the open-circuit potential (OCP). The passive layers were studied at the OCP by X-ray photoelectron spectroscopy (XPS). The passive films on both materials predominantly contained Cr-oxides, whereas the Fe species were markedly depleted.

  16. Effect of heat treatment on an AISI 304 austenitic stainless steel evaluated by the ultrasonic attenuation coefficient

    Energy Technology Data Exchange (ETDEWEB)

    Moghanizadeh, Abbas; Farzi, Abolfazl [Islamic Azad Univ., Esfarayen (Iran, Islamic Republic of). Dept. of Civil Engineering

    2016-07-01

    The properties of metals can be substantially changed by various methods, one of them is using heat treatment processes. Moreover, ultrasonic testing is the most preferred and effective, nondestructive testing technique for characterization of mechanical material properties. Austenitic stainless steel AISI 304 serves in many applications due to high strength and corrosion resistance. In certain applications, it is important to evaluate the mechanical properties of AISI 304 stainless steel. In this study, the ultrasonic method (attenuation measurement technique) is used to evaluate the hardness of AISI 304 stainless steel samples which were heat treated at different levels. Due to the heat treatment process, each sample has its specific microstructure and hardness which attenuate ultrasonic waves appropriately. The ultrasonic and hardness test show that it is possible to evaluate the hardness of AISI 304 stainless steel by ultrasonic attenuation coefficient. In addition, the relationship between ultrasonic attenuation coefficients and time of heat treatment is investigated.

  17. An experimental investigation on the slow strain rate corrosion of 316L stainless steel containing H2S and Cl-%316L钢在含H2S、Cl-水溶液中的慢应变速率腐蚀试验研究

    Institute of Scientific and Technical Information of China (English)

    董绍平; 袁军国; 方德明; 高增梁; 张庆; 刘富胜

    2001-01-01

    通过慢应变速率法(SSRT)应力腐蚀试验,得到了316L钢的应力腐蚀敏感性指数,回归出计算应力腐蚀敏感性指数的方程,表明水溶液中Cl-对316L钢的应力腐蚀影响较大,而H2S的影响小。%Through the stress corrosion test of slow strain rate test, the sensitive indexes of the stress corrosion of 316L stainless steel was derived, the regression equation was given for calculating the sensitive indexes of stress corrosion of 316L stainless steel. It shows that the influence of Cl- in solution on the stress corrosion of 316L stsinless steel was some strong and the influence of H2S in solution on the stress corrosion of 316L stainless steel was small.

  18. Creep-fatigue propagation of semi-elliptical crack at 650 deg. C in 316L(N) stainless steel plates with or without welded joints; Propagation de fissures semi-elliptiques en fatigue-fluage a 650 deg. C dans des plaques d'acier 316L(N) avec ou sans joints soudes

    Energy Technology Data Exchange (ETDEWEB)

    Curtit, F

    2000-07-01

    This study realised in LISN Laboratory of CEA Saclay, deals with the creep fatigue propagation of semi elliptical crack at the temperature of 650 deg C in 316L(N) stainless steel plates with or without welded joints. A vast majority of the studies on creep fatigue propagation models are based on specimen (CT) especially designed for crack propagation study. The PLAQFLU program performed in LISN laboratory deals with the application and adaptation of these models to complex crack shape, which are more representative of the cracks observed in industrial components. In this scope, we use propagation tests realised at the temperature of 650 deg C with wide plates containing semi elliptical defects. For some of them, the initial defect is machined in the middle of a welded joint, which constitute a privileged site for the crack initiation. The approach used in this study is based on global parameters of fracture mechanics. At first, tests on CT specimen are used in order to determine the propagation laws correlating the crack growth rate to the global parameters K or C{sup *}. These laws are then supposed to be intrinsic to our materials and are used to analysed the semi elliptical crack propagation. The analysis of the comportment of the crack during the hold time demonstrates the possibility to establish a correlation between the crack propagation both in the deepest and the surface point and the local value of C{sup *}. These correlations are coherent in the different points of the crack front for the different applied hold times, and they present a reasonably good agreement with the creep propagation law identified on CT specimen. The simulation of test performed on based metal specimen with a model of summation of both creep and pure fatigue crack growth gives acceptable results when the calculus of the simplified expression of C{sup *}{sub s} considers a continuous evolution of creep deformations rate during the all test. (author)

  19. Evaluation of performance of AISI 444 steel for application in distillation towers; Avaliacao do desempenho do aco AISI 444 para aplicacao como 'lining' em torres de destilacao

    Energy Technology Data Exchange (ETDEWEB)

    Guimaraes, R.F.; Miranda, H.C. de; Farias, J.P. [Universidade Federal do Ceara (DEMM/UFC), Fortaleza, CE (Brazil). Dept. de Engenharia Metalurgica e de Materiais. Lab. de Caracterizacao de Materiais], e-mail: rf.guimaraes@yahoo.com.br

    2008-07-01

    In this work, the behavior of the AISI 444 ferritic stainless steel submitted to thermal fatigue test and their corrosion resistance in heavy crude oil was evaluated. The AWS E309MoL-16 and E316L-17 weld metal was employed as filler metal. Plates of the AISI 444 were welded on ASTM A-516 Gr. 60 plates and submitted to fatigue thermal cycle. Samples were extracted from plates welded and heat treated immersed in heavy crude oil at 300 deg C. Optical microscopy (OM), scanning electron microscopy (SEM) and energy dispersive of X-ray analysis (EDX) were used to characterize the microstructure and the corroded surface. The results show that the AISI 444 stainless steels did not present cracks after the thermal fatigue cycle and the heat treated immerse in heavy crude oil. The electrode AWS E309MoL-16 show better corrosion resistance than the AWS E316L-17. (author)

  20. EFFECTS OF COPPER ION IMPLANTATION ON ANTIBACTERIAL ACTIVITY OF AISI420 STAINLESS STEEL

    Institute of Scientific and Technical Information of China (English)

    Z.G. Dan; H.W. Ni; B.F. Xu; J. Xiong; P. Y. Xiong

    2005-01-01

    Antibacterial activity of AISI420 stainless steel (SS) implanted by copper was investigated. Ions extracted from a metal vapor vacuum arc (MEVVA) are sourced with 100keV energy and a dose range from 0.2×1017 to 2.0×1017ions .cm-2. The saturation dose of Cu implantation in AISI420 SS and Cu surface concentration were calculated at the energy of 100keV. The effect of dose on the antibacterial activity was analyzed. Results of antibacterial test show that the saturation dose is the optimum implantation dose for best antibacterial activity, which is above 99% against both Escherichia coli and Staphylococcus aureus. Novel phases such as Fe4Cu3 and Cu9.9Fe0.1 were found in the implanted layer by glancing angle X-ray diffraction (GXRD). The antibacterial activity of AISI420 SS attributes to Cu-contained phase.

  1. Constitutive modelling and identification of parameters of the plastic strain-induced martensitic transformation in 316L stainless steel at cryogenic temperatures

    CERN Document Server

    Garion, C; Sgobba, Stefano

    2006-01-01

    The present paper is focused on constitutive modelling and identification of parameters of the relevant model of plastic strain- induced martensitic transformation in austenitic stainless steels at low temperatures. The model used to describe the FCCrightward arrow BCC phase transformation in austenitic stainless steels is based on the assumption of linearization of the most intensive part of the transformation curve. The kinetics of phase transformation is described by three parameters: transformation threshold (p/sub xi/), slope (A) and saturation level (xi/sub L/). It is assumed that the phase transformation is driven by the accumulated plastic strain p. In addition, the intensity of plastic deformation is strongly coupled to the phase transformation via the description of mixed kinematic /isotropic linear plastic hardening based on the Mori-Tanaka homogenization. The theory of small strains is applied. Small strain fields, corresponding to phase transformation, are decomposed into the volumic and the shea...

  2. Selective laser melting of 316L stainless steel powder molding process optimization%选择性激光熔化316L不锈钢粉成形优化工艺

    Institute of Scientific and Technical Information of China (English)

    赵灿; 张佳; 刘锦辉

    2013-01-01

    Aimed at addressing a lower density, poorer forming accuracy, and lower surface finish revealed by selective laser melting technology used to machine parts, this paper proposes an orthogonal experiment method to optimize the technology designed for forming 316L stainless steel powder into parts using selective laser melting process. The paper discusses the study of the effect of laser power, scanning speed and scanning interval on parts forming density and an analysis of the surface morphology of the specimen. Experimental results show that directly melting 316L stainless steel powder into forms leads to the sample boasting a higher density, a density up to 80. 1%. The optimized process gives such parameters as 300 W for laser power, 800 mm/s for the scanning speed of, and 0. 08 mm for the scanning interval, capable of successfully manufacturing parts at the set of optimized parameters.%针对选择性激光熔化技术加工零件存在的致密度低、成形精度差和表面光洁度低的问题,利用正交实验的方法优化316L不锈钢粉末成形零件的工艺,研究激光功率、扫描速度、扫描间距对零件成形致密度的影响,分析了试样的表面形貌.实验结果表明:采用选择性激光熔化工艺的316L不锈钢粉末试样有较高致密度,其试样的致密度达80.1%.工艺优化后的参数为激光功率300 W、扫描速度800 mm/s、扫描间距0.08 mm,并在该组优化参数条件下成功制造零件.

  3. In Situ Observation of Solidification Process of AISI 304 Austenitic Stainless Steel

    Institute of Scientific and Technical Information of China (English)

    HUANG Fu-xiang; WANG Xin-hua; ZHANG Jiong-ming; JI Chen-xi; FANG Yuan; YU Yan

    2008-01-01

    The solidification process of AISI 304 stainless steel during cooling at a rate of 0.05 K/s has been observed in situ using a confocal scanning laser microscope(CSLM).The results show that the δ phase appeared first in liquid steel,as the temperature decreased,the γ phase precipitated prior at δ-grain boundary at 1452.2℃,the liquid steel disappeared at 1431.3℃,and then theγphase precipitated on the δ ferrite.Based on the Scheil-GulliVer solidification model,the solidification processes of AISI 304 stainless steel are simulated using the Scheil model in Thermo-Calc.and the simulation results agree well with the results observed in the experiment.

  4. Distribution of soluble and precipitated iron and chromium products generated by anodic dissolution of 316L stainless steel and alloy C-22: final report

    Energy Technology Data Exchange (ETDEWEB)

    Estill, J; Farmer, J; Gordon, S; King, K; Logotetta, L; Silberman, D

    1999-08-11

    At near neutral pH and at applied potentials above the threshold potential for localized breakdown of the passive film, virtually all of the dissolved chromium appeared to be in the hexavalent oxidation state (Cr(VI)). In acidic environments, such as crevice solutions formed during the crevice corrosion of 316L and C-22 samples in 4 M NaCl, virtually all of the dissolved chromium appeared to be in the trivalent oxidation state (Cr(III)). These general observations appear to be consistent with the Pourbaix diagram for chromium (Pourbaix 1974), pp. 307-321. At high pH and high anodic polarization (pH {approximately} 8 and 800 mV vs. SHE), the predominate species is believed to be the soluble chromate anion (CrO{sub 4}{sup 2{minus}}). At the same pH, but lower polarization (pH {approximately} 8 and 0 mV vs. SHE), the predominate species are believed to be precipitates such as trivalent Cr(OH){sub 3} {center_dot} n(H{sub 2}O) and hexavalent Cr{sub 2}O{sub 3}. In acidified environments such as those found in crevices (pH < 3), soluble Cr{sup 3+} is expected to form over a wide range of potential extending from 400 mV vs. SHE to approximately 1200 mV vs. SHE. Again, this is consistent with the observations from the creviced samples. In earlier studies by the principal investigator, it has been found that low-level chromium contamination in ground water is usually in the hexavalent oxidation state (Farmer et al. 1996). In general, dissolved iron measured during the crevice experiments appears to be Fe(II) in acidic media and Fe(III) in near-neutral and alkaline solutions (table 3). In the case of cyclic polarization measurements, the dissolved iron measured at the end of some cyclic polarization measurements with C-22 appeared to be in the Fe(III) state. This is probably due to the high electrochemical potential at which these species were generated during the potential scan. Note that the reversal potential was approximately 1200 mV vs. Ag/AgCl during these scans. These

  5. Welding of AA1050 aluminum with AISI 304 stainless steel by rotary friction welding process

    OpenAIRE

    Chen Ying An; Francisco Piorino Neto; Eder Paduan Alves

    2010-01-01

    The purpose of this work was to assess the development of solid state joints of dissimilar material AA1050 aluminum and AISI 304 stainless steel, which can be used in pipes of tanks of liquid propellants and other components of the Satellite Launch Vehicle. The joints were obtained by rotary friction welding process (RFW), which combines the heat generated from friction between two surfaces and plastic deformation. Tests were conducted with different welding process parameters. The results we...

  6. Cathodic cage nitriding of AISI 409 ferritic stainless steel with the addition of CH4

    Directory of Open Access Journals (Sweden)

    Rômulo Ribeiro Magalhães de Sousa

    2012-04-01

    Full Text Available AISI 409 ferritic stainless steel samples were nitrided using the cathodic cage plasma nitriding technique (CCPN, with the addition of methane to reduce chromium precipitation, increase hardness and wear resistance and reduce the presence of nitrides when compared to plasma carbonitriding. Microhardness profiles and X-Ray analysis confirm the formation of a very hard layer containing mainly ε-Fe3N and expanded ferrite phases.

  7. Mechanical and Microstructural Properties of Friction Welded AISI 304 Stainless Steel to AISI 1060 Steel AISI 1060

    Directory of Open Access Journals (Sweden)

    Ates H.

    2014-10-01

    Full Text Available Rotary Friction welding is one of the most popular methods of joining similar and dissimilar materials. It is widely used with metals and thermoplastics in a wide variety of aviation, transport and aerospace industrial component designs. This study investigates the influence of friction and upsetting pressures on the hardness, tensile properties and microstructure of the welds. The experimental results showed that as the friction and upsetting pressures increased, the hardness and tensile strength values increased, as well. The tensile fracture of welded joint occurred in the AISI 1060 side. The friction processed joints were evaluated for their integrity and quality aspects by optical and scanning electron microscopy. For the perfect interfacial bonding, sufficient upsetting and friction pressures are necessary to reach the optimal temperature and severe plastic deformation to bring these materials within the attraction range.

  8. Response of duplex Cr(N)/S and Cr(C)/S coatings on 316L stainless steel to tribocorrosion in 0.89% NaCl solution under plastic contact conditions.

    Science.gov (United States)

    Sun, Y; Dearnley, P A; Mallia, Bertram

    2016-04-27

    Two duplex coatings, Cr(N)/S and Cr(C)/S, were deposited on 316 L stainless steel by magnetron sputtering. The effectiveness of these duplex coatings in improving the tribocorrosion behavior of medical alloys under elastic contact conditions has been demonstrated in a recent publication. The present work focused on the response of these duplex coatings to tribocorrosion under plastic contact conditions. Tribocorrosion tests were conducted in 0.89% NaCl solution at 37°C at an initial contact pressure of 740 MPa and under unidirectional sliding conditions for sliding duration up to 24 h. The results showed that during sliding in the corrosive solution, the duplex coatings were plastically deformed into the substrate to a depth about 1 μm. The Cr(C)/S duplex coating had sufficient ductility to accommodate the deformation without cracking, such that it was worn through gradually, leading to the gradual increase in open circuit potential (OCP) and coefficient of friction (COF). On the other hand, the Cr(N)/S duplex coating suffered from cracking at all tested potentials, leading to coating blistering after prolonged sliding at OCP and stable pit formation in the substrate beneath the coating at applied anodic potentials. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2016.

  9. Structure and properties of the Stainless steel AISI 316 nitrided with microwave plasma; Estructura y propiedades del acero inoxidable AISI 316 nitrurado con plasmas de microondas

    Energy Technology Data Exchange (ETDEWEB)

    Becerril R, F

    1999-07-01

    In this work were presented the results obtained by nitridation on stainless steel AISI 316 using a plasma generated through a microwave discharge with an external magnetic field using several moistures hydrogen / nitrogen to form a plasma. The purpose of nitridation was to increase the surface hardness of stainless steel through a phase formation knew as {gamma}N which has been reported that produces such effect without affect the corrosion resistance proper of this material. (Author)

  10. Surface integrity and part accuracy in reaming and tapping stainless steel with new vegetable based cutting oils

    DEFF Research Database (Denmark)

    Belluco, Walter; De Chiffre, Leonardo

    2002-01-01

    This paper presents an investigation on the effect of new formulations of vegetable oils on surface integrity and part accuracy in reaming and tapping operations with AISI 316L stainless steel. Surface integrity was assessed with measurements of roughness, microhardness, and using metallographic ...

  11. Preparation of high-performance ultrafine-grained AISI 304L stainless steel under high temperature and pressure

    Directory of Open Access Journals (Sweden)

    Peng Wang

    2016-08-01

    Full Text Available Bulk ultra-fine grained (UFG AISI 304L stainless steel with excellent mechanical properties was prepared by a high-temperature and high-pressure (HTHP method using nanocrystalline AISI 304L stainless steel powders obtained from ball milling. Samples were sintered in high-pressure conditions using the highest martensite content of AISI 304L stainless steel powders milled for 25 h. Analyses of phase composition and grain size were accomplished by X-ray diffraction and Rietveld refinement. By comparing the reverse martensite transformation under vacuum and HTHP treat, we consider that pressure can effectively promote the change in the process of transformation. Compared with the solid-solution-treated 304L, the hardness and yield strength of the samples sintered under HTHP are considerably higher. This method of preparation of UFG bulk stainless steel may be widely popularised and used to obtain UFG metallic materials with good comprehensive performance.

  12. Elaboración del plan HACCP para gestión de inocuidad en la línea de proceso de salchichas de una planta de productos cárnicos cárnicos1 Cytotoxic and genotoxic study of in vitro released productos of stainless steel 316L with bioactive ceramic coatings

    Directory of Open Access Journals (Sweden)

    Diana Cortés

    2003-01-01

    Full Text Available

    La enfermedad transmitida por alimentos (ETA es el síndrome
    originado por la ingestión de alimentos y/o agua con contaminación
    química, física o biológica que puede afectar la salud. La frecuencia de ETA es aproximadamente de mil millones de casos/año en el mundo y está entre las primeras causas de muerte en niños.


    Un alimento inocuo no debe presentar riesgos químicos, físicos
    o biológicos para el consumidor y no genera efectos adversos sobre
    su calidad de vida ni su salud. El Sistema de Análisis de Riesgos y
    Control en Puntos Críticos (HACCP con fundamentos científicos y
    carácter sistemático identifica peligros y medidas para controlarlos,
    para garantizar la inocuidad de los alimentos. El objetivo de este
    trabajo fue aplicar los principios HACCP y elaborar el plan HACCP para
    la línea de proceso de salchichas.

    The stainless steel AISI 316L is the must used biomaterial for the making of temporal prosthesis, but it presents severe limitations for permanent implants due to the generation and migration of metallic ions to the surrounding peripheral tissues, which produces oxygen reactive species (ERO and damages of the ADN, increasing the possibility of local tumors and mechanical failure of the implant. A strategy used to minimize the generation of ions is the superficial modification of the implants by means of inorganic coatings, ceramic or vitreous, applied by the sol-gel process; this method has a series of comparative advantages, compared to other deposition methods, as good adherence, easy application, minimum drying problems, low densification temperatures and the possibility of adding particles and/or organic groups that improve the adhesion of the cell to the implant, increasing the biocompatibility. In the present work, the citotoxic effects were valuated by means of the MTT technique, and the genotoxic ones by electrophoresis of individual cell gels (Cometa

  13. Electrochemical behaviour of iron and AISI 304 stainless steel in simulated acid rain solution

    Energy Technology Data Exchange (ETDEWEB)

    Pilic, Zora; Martinovic, Ivana [Mostar Univ. (Bosnia and Herzegovina). Dept. of Chemistry

    2016-10-15

    The growth mechanism and properties of the oxide films on iron and AISI 304 stainless steel were studied in simulated acid rain (pH 4.5) by means of electrochemical techniques and atomic absorption spectrometry. The layer-pore resistance model was applied to explain a potentiodynamic formation of surface oxides. It was found that the growth of the oxide film on iron takes place by the low-field migration mechanism, while that on the stainless steel takes place by the high-field mechanism. Kinetic parameters were determined. Impedance measurements revealed that Fe surface film has no protective properties at the open circuit potential, while the resistance of stainless steel oxide film is very high. The concentration of the metallic ions released into solution and measured by atomic absorption spectroscopy was in accordance with the results obtained from the electrochemical techniques.

  14. Physical properties of the AISI 348 L{sup *} austenitic stainless steel; Propriedades fisicas do aco inoxidavel austenitico AISI 348 L{sup *}

    Energy Technology Data Exchange (ETDEWEB)

    Teodoro, Celso Antonio; Lucki, Georgi; Silva, Jose Eduardo Rosa da; Terremoto, Luis Antanio Albiac; Castanheira, Myrthes; Damy, Margaret de Almeida [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil)]. E-mail: cteodoro@ipen.br

    2005-07-01

    The study of radiation damage in metals and alloys, used as structural materials of nuclear reactors has a strategic meaning in nuclear technology, because it allows the performance evaluation of these materials in working conditions of PWR. For this sake it is necessary to know the detrimental structural changes that occur during fast neutron irradiation. The aim of the present work is to show some strain-stress results of the AISI 348 L{sup *} stainless steel utilized as a structural material of the fuel elements of PWR, in comparison with the AISI 304. (author)

  15. Microstructures and properties of porous filter parts of selective laser melted 316 L stainless steel%选区激光熔化316 L不锈钢多孔过滤零件的组织性能研究

    Institute of Scientific and Technical Information of China (English)

    孙健峰; 杨洲; 杨永强; 王迪

    2016-01-01

    Objective]To reveal the formation patterns and mechanisms of selective laser melted 316 L stainless steel porous filter parts. [Method]Both cubical and cylindrical 316L stainless steel porous filter parts with 1 mm pore size were designed and formed by selective laser melting ( SLM) . Microstructures and properties of these filter parts were investigated using optical microscope, scanning electron micro-scope and X-ray diffraction. Micro hardness of the parts was measured using microhardness tester.[Re-sult]The formed filter parts were obtained with 95% density and without defects such as pore, crack and segregation . The intra-structure was mainly composed of dendrite crystals which were vertical to the inter-face and grew along the epitaxy. The microstructure obtained had even layers which were metallurgically bonded. There was clear evidence of directional solidification for the formed parts. [Conclusion] The formed parts are composed of austenite, and microhardness ranges from 258 to 294 HV0. 3. SLM can be used in prototyping filter parts with relatively small pore size.%【目的】揭示选区激光熔化316L不锈钢粉末成型多孔过滤零件的成型规律和机理。【方法】试验设计孔洞尺寸为1 mm的圆形、正方形多孔316L不锈钢过滤零件,采用选区激光熔化方法进行成型,选用光学显微镜、扫描电子显微镜、X射线衍射等手段对其组织特征和性能进行分析检测,采用显微硬度计测量其显微硬度。【结果】获得了无气孔、裂纹、偏析等缺陷,且致密度达到95%的成型组织。组织内部主要由垂直于界面呈现外延生长的树枝晶组成,所得组织分层均匀,各层间呈冶金结合,定向凝固特征明显。【结论】多孔过滤零件成型件由奥氏体组成,显微硬度为:258~294 HV0.3。采用选区激光熔化方法可以成型孔洞尺寸较小的过滤零件。

  16. 工艺参数对激光熔覆成形316L不锈钢形状的影响规律%Influences of Processing Parameters on Geometric Characterizations of Laser Cladding Forming 316L Stainless Steel

    Institute of Scientific and Technical Information of China (English)

    黄小伟; 习俊通; J. L. Lebrun; Elcheikh Hussam; Courant Bruno

    2011-01-01

    激光熔覆技术经多年发展已取得许多成功的工业应用,但如何控制工艺以达到最佳成形效果,需要通过研究工艺参数与成形精度之间的关系才能找到最终的解决方案.借助激光熔覆快速成形法制备316L不锈钢实验试样,研究工艺参数组合对成形试样形状的影响规律.通过定义单涂覆层截面形状特征参数,采用线性相关法处理截面形状数据,建立工艺参数组合与截面形状特征参数的线性关系.此外,激光熔覆成形件易出现两类典型缺陷,即晶界间微裂纹和层间熔合不良缺陷.%After years of development of laser cladding forming technology, it has made many successful industrial applications. However, how to control the process to achieve the best forming results? We need study the relationship between the processing parameters and the forming accuracy to find the ultimate best solution. We prepare the 316L stainless steel specimens using the laser cladding forming to investigate the influences of processing parameters on geometric characterizations. Five parameters are defined to describe the geometric characterization of single layer cross section, and then the measurement data is processed with the linear regression method to establish relations between processing parameters and defined parameters. In addition, the laser cladding parts prone to two types of typical defects: micro-cracks between grain boundaries and poor fusion defects between two layers.

  17. Preparation of Honeycomb-like Porous 316L Stainless Steel by Selective Laser Melting%蜂窝状多孔316L不锈钢的选区激光熔化制备

    Institute of Scientific and Technical Information of China (English)

    王志阳; 沈以赴; 顾冬冬; 于秀平

    2011-01-01

    对含预合金316L不锈钢和NH4HCO3(质量比96:4)的混合粉末进行选区激光熔化,制备多孔材料的实验研究.利用扫描电镜分析试样的微观孔隙特征.结果表明,在较高激光功率(800 W)条件下,可形成蜂窝状的多孔结构,孔径分布均匀(2~5 μm),平均孔径约3.5 μm.分析激光功率对多孔结构特征的影响,讨论选区激光熔化蜂窝状多孔结构的形成机制.%The selective laser melting of a blended powder system consisting of 96wt% 316L stainless steel and 4wt% NH4HCO3 was performed to prepare porous materials.The SEM characterizations show the formation of a honeycomb-like porous structure at a relatively high laser power of 800 W.The pore sizes of the porous structure distribute homogeneously, typically in a range of 2-5 μm.The average pore size is about 3.5 μm.The effects of laser power on the microstructural characteristics of the as-obtained microcellular structures were investigated.The formation mechanisms of the honeycomb-like porous structure during selective laser melting were also discussed.

  18. Adsorption of Cd(II) and Pb(II) by in situ oxidized Fe3O4 membrane grafted on 316L porous stainless steel filter tube and its potential application for drinking water treatment.

    Science.gov (United States)

    Zhu, Mengfei; Zhu, Li; Wang, Jianlong; Yue, Tianli; Li, Ronghua; Li, Zhonghong

    2017-03-08

    Removing heavy metal ions from aqueous solutions is one of the most challenging separations. In situ oxidized Fe3O4 membranes using 316L porous stainless steel filter tube have shown great potential for removing anion Cr(VI). Here we report the performances of the in situ oxidized Fe3O4 membranes for removing two toxic cations Cd(II) and Pb(II) commonly existing in water and their potential applications for drinking water purification. The membranes exhibited high removal efficiency: 97% at pH 9.0 for Cd(II) of 1.0 mg/L initial concentration and 100% at pH 5.0-6.0 for Pb(II) of 5.0 mg/L initial concentration. The maximum adsorption capabilities were estimated at 0.800 mg/g and 2.251 mg/g respectively for Cd(II) and Pb(II) at 318 K by the Langmuir model. Results of batch tests revealed the existence of electrostatic attraction and chemisorption. XRD and FT-IR analyses indicated that the chemisorption might be the insertion of Cd(II) and Pb(II) into the Fe3O4 crystal faces of 311 and 511 to form mononuclear or binuclear coordination with O atoms of Fe-O6 groups. Competitive adsorption of Cd(II) and Pb(II) in binary solutions revealed a preferential adsorption for Pb(II). Na2EDTA solution was used to regenerate the membranes, and the maximum desorption ratio was 90.29% and 99.75% respectively for Cd(II) and Pb(II). The membranes were able to efficiently lower Cd(II) and Pb(II) concentrations to meet the drinking water standards recommended by the World Health Organization and are promising for engineering applications aimed at drinking water purification.

  19. Improving by postoxidation of corrosion resistance of plasma nitrocarburized AISI 316 stainless steels

    Science.gov (United States)

    Yenilmez, A.; Karakan, M.; Çelik, İ.

    2017-01-01

    Austenitic stainless steels are widely used in several industries such as chemistry, food, health and space due to their perfect corrosion resistance. However, in addition to corrosion resistance, the mechanic and tribological features such as wear resistance and friction are required to be good in the production and engineering of this type of machines, equipment and mechanic parts. In this study, ferritic (FNC) and austenitic (ANC) nitrocarburizing were applied on AISI 316 stainless steel specimens with perfect corrosion resistance in the plasma environment at the definite time (4 h) and constant gas mixture atmosphere. In order to recover corrosion resistance which was deteriorated after nitrocarburizing again, plasma postoxidation process (45 min) was applied. After the duplex treatment, the specimens' structural analyses with XRD and SEM methods, corrosion analysis with polarization method and surface hardness with microhardness method were examined. At the end of the studies, AISI 316 surface hardness of stainless steel increased with nitrocarburizing process, but the corrosion resistance was deteriorated with FNC (570 °C) and ANC (670 °C) nitrocarburizing. With the following of the postoxidation treatment, it was detected that the corrosion resistance became better and it approached its value before the process.

  20. PARAMETRIC STUDY OF ELECTRICAL DISCHARGE MACHINING OF AISI 304 STAINLESS STEEL

    Directory of Open Access Journals (Sweden)

    P. SRINIVASA RAO,

    2010-08-01

    Full Text Available Electrical discharge machining (EDM is widely used process in the production of mould / dies, aerospace, automobile and electronics industries where intricate complex shapes need to be machined in very hard materials. The selection of the AISI 304 stainless steel was made taking into account its use in almost all industrial applicationsfor approximately 50% of the world’s stainless steel production and consumption. In this work, a study has been carried out on the influence of four design factors: current, open-circuit voltage, servo and dutycycle over material removal rate, tool wear rate, surface roughness and hardness on the die-sinking electrical discharge machining of AISI 304 stainless steel. This has been done using design of experiments (DOE, which allows us to carry out theabove-mentioned analysis performing a relatively small number of experiments. In this case, a 3*24-1 mixed level factorial design, whose resolution is V, has been selected due to the number of factors considered in the study. The resolution of this mixed factorial design allows us to estimate all the main effects, two-factor interactions and pure quadratic effects of the four design factors selected to perform this study.

  1. Physical and Tribological Properties of Nitrided AISI 316 Stainless Steel Balls

    Directory of Open Access Journals (Sweden)

    Yang Shicai

    2016-01-01

    Full Text Available AISI 316 austenitic stainless steel balls (diameters 5.0 and 12.0 mm, typical hardness 250 HV0.3 and flat samples (20×20×2.0 mm were nitrided by a pulsed glow discharge Ar/N2 plasma. Hardness of the ball surfaces was analysed using Vickers indentation. Thermal stability of the nitrided balls (diameter 12.0 mm was studied using a furnace to heat them in air for 8 hours at temperatures up to 700.0°C and then, after cooling to room temperature, the surface hardness of the heated balls was re-measured. Scanning electron microscopy and X-ray diffraction were used to study the microstructures, composition and phase formation of the nitrided sublayers. Unlubricated pin-on-disc wear testing was used to evaluate the wear resistance of nitrided stainless steel balls (5.0 mm diameter and the results were compared with similar testing on hardened Cr-Steel balls (5 mm diameter with hardness of about 650 HV0.3. All the test results indicated that the nitrided AISI 316 austenitic stainless steel balls have advantages over the hardened Cr-Steel balls in terms of retaining high hardness after heat treatment and high resistance to sliding wear at room temperature under higher counterpart stress. These properties are expected to be beneficial for wide range of bearing applications.

  2. Pitting and Intergranular Corrosion Resistance of AISI Type 301LN Stainless Steels

    Science.gov (United States)

    Ningshen, S.; Kamachi Mudali, U.

    2010-03-01

    The pitting and intergranular corrosion (IGC) resistance of AISI type 301LN stainless steels were evaluated using ASTM methods, anodic polarization, and electrochemical impedance techniques. The IGC results indicated that the microstructure of the samples after sensitization heat treatment at 675 °C for 1 h shows step or dual structure for both imported and indigenous materials indicating insignificant Cr23C6 precipitation. The results of immersion tests in boiling 6% copper sulfate + 16% sulfuric acid + copper solution for 24 h followed by the bend test (ASTM A262 Practice-E method) indicated no crack formation in any of the tested specimens. Pitting corrosion resistance carried out in 6% FeCl3 solution at different temperatures of 22 ± 2 and 50 ± 2 °C (ASTM G 48) up to the period of 72 h revealed pitting corrosion attack in all the investigated alloys. The potentiodynamic anodic polarization results in 0.5 M NaCl revealed variation in passive current density and pitting potential depending on the alloy chemistry and metallurgical condition. The passive film properties studied by electrochemical impedance spectroscopy (EIS) correlated well with the polarization results. The x-ray diffraction (XRD) results revealed the presence of austenite (γ) and martensite (α') phases depending on the material condition. The suitability of three indigenously developed AISI type 301LN stainless steels were compared with imported type 301LN stainless steel and the results are highlighted in this article.

  3. Corrosion resistance and its mechanism of Ni-Cu-P coating and 316L stainless steel in hot hydrochloric acid solution%Ni-Cu-P镀层和316L不锈钢在热盐酸溶液中的耐蚀性及机制

    Institute of Scientific and Technical Information of China (English)

    薛亚军

    2013-01-01

    Effect of temperature and concentration on the corrosion behavior of Ni-Cu-P coating and 316L stainless steel was studied by mass loss method.The results show that the corrosion resistance of Ni-Cu-P coating is better than that of 316L stainless steel in hot hydrochloric acid solution.The effect of hydrochloric acid concentration on the corrosive rate of 316L stainless steel is greater than that of Ni-Cu-Pcoating.The corrosive rates of 316L stainless steel and Ni-Cu-P coating increase 2.7 and 0.6 times respectively while increasing hydrochloric acid concentration from 5% to 20%.For the Ni-Cu-P coating,the uniform corrosion occurs in the hydrochloric acid solution.However,the selective corrosion mechanism is found for 316L stainless steel,and the higher temperature and concentration of corrosion medium,the more serious selective corrosion.%采用质量损失法研究了温度和浓度对化学镀Ni-Cu-P镀层和316L不锈钢在盐酸溶液中的腐蚀行为.结果表明,在高温盐酸溶液中,Ni-Cu-P镀层的耐蚀性优于316L不锈钢,盐酸浓度对316L不锈钢腐蚀速率的影响大于Ni-Cu-P镀层,盐酸浓度由5%升高到20%,316L不锈钢和Ni-Cu-P镀层的腐蚀速率分别增大了2.7倍和0.6倍;在盐酸溶液中,Ni-Cu-P镀层发生均匀腐蚀,316L不锈钢发生选择性腐蚀,且温度和浓度越高,选择性腐蚀越严重.

  4. Estimation of embrittlement during aging of AISI 316 stainless steel TIG welds

    Indian Academy of Sciences (India)

    J Nayak; K R Udupa; K R Hebbar; H V S Nayak

    2004-12-01

    Weldments of AISI grade 316 stainless steel, having a ferrite content of 4–6% and a variety of nitrogen concentrations were prepared using a modified element implant technique. Charpy impact specimens prepared from these weldments were subjected to a variety of aging treatments. Impact toughness decreases with aging time at all aging temperatures. Nitrogen is found to be beneficial to toughness. An empirical relation connecting the aging temperature, aging time and nitrogen content with toughness has been developed which can be used to estimate the time for embrittlement.

  5. Biaxial fatigue tests of notched specimens for AISI 304L stainless steel

    Directory of Open Access Journals (Sweden)

    G. Beretta

    2016-07-01

    Full Text Available High cycle fatigue tests were conducted for stainless steel AISI 304L. The geometry was a thin walled tube with a passing through hole. The tests were axial, torsional and in-phase axial-torsional, all of them under load control with R = −1. The S-N curves were constructed following the ASTM E739 standard and the fatigues limits were calculated following the method of maximum likelihood proposed by Bettinelli. The crack direction along the surface was analysed, with especial attention to the crack initiation zones. The notch fatigue limits for different hole diameters were compared with the predictions done with a microstructural fracture mechanics model.

  6. Microstructural changes due to laser surface melting of an AISI 304 stainless steel

    Directory of Open Access Journals (Sweden)

    d?Oliveira A.S.C.M.

    2001-01-01

    Full Text Available Several techniques can be used to improve surface properties. These can involve changes on the surface chemical composition (such as alloying and surface welding processes or on the surface microstructure, such as hardening and melting. In the present work surface melting with a 3kW CO2 cw laser was done to alter surface features of an AISI 304 stainless steel. Microstructure characterisation was done by optical and scanning electron microscopy. Vickers and Knoop microhardness tests evaluated mechanical features after surface melting. Phase transformation during rapid solidification is analysed and discussed.

  7. PITTING CORROSION OF AISI 316Ti STAINLESS STEEL WITH POLISHED SURFACE

    Directory of Open Access Journals (Sweden)

    Viera Zatkalíková

    2010-05-01

    Full Text Available AISI 316Ti is Cr–Ni–Mo austenitic stainless steel with the high Pitting Resistance Equivalent Number (PREN. The effect of the surface finishing by polishing on the pitting corrosion resistance was tested in aggressive 5% FeCl3 solution. The immersion tests were curried out at the temperature 30, 50, 80 °C. The electrochemical cyclic potentiodynamic tests were carried out in the same solution at temperature 30 and 50 °C. The evaluation of the corrosion resistance arose from the comparison of the results of the immersion and the cyclic potentiodynamic tests.

  8. Investigating early stages of biocorrosion with XPS: AISI 304 stainless steel exposed to Burkholderia species

    Science.gov (United States)

    Johansson, Leena-Sisko; Saastamoinen, Tuomas

    1999-04-01

    We have investigated the interactions of an exopolymer-producing bacteria, Burkholderia sp. with polished AISI 304 stainless steel substrates using X-ray photoelectron spectroscopy (XPS). Steel coupons were exposed to the pure bacteria culture in a specially designed flowcell for 6 h during which the experiment was monitored in situ with an optical microscope. XPS results verified the formation of biofilm containing extracellular polymer on all the samples exposed to bacteria. Sputter results indicated that some ions needed for metabolic processes were trapped within the biofilm. Changes in the relative Fe concentration and Fe 2p peak shape indicated that also iron had accumulated into the biofilm.

  9. Effects of cold working on the pitting corrosion behavior s of AISI 304 stainless steels

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Kee Min; Kim, Jong Soo; Kim, Young Jun; Kwon, Houk Sang [KAIST, Daejon (Korea, Republic of)

    2015-12-15

    These microstructural changes by cold working can lead improvement of mechanical properties, however from a corrosion resistant point of view, the effects of cold working on the corrosion resistance of stainless steel have been argued. Several studies has been focused on the influence of cold working on the localized corrosion resistance of stainless steels. However, the opinions about the role of cold working on the localized corrosion resistance are highly in consistence. Some studies report that the pitting potential of austenitic stainless steels decreased with cold working level, on the other hands, other studies claimed that the pitting resistance was increased by cold working. Therefore it is necessary to verify how cold working affects pitting corrosion behavior of austenitic stainless steels. In the present work, the influence of cold working on the localized corrosion of AISI 304stainless steel in the neutral chloride solution was studied based on point defect model (PDM). The fraction of deformation-induced martensite was linearly increased with cold rolling level. Through cold rolling, the pitting potential was decreased, the metastable pitting event density was significantly increased and the repassivation potential was decreased. The overall localized corrosion resistance was decreased with cold working, however cold working level increased from 30 % to 50 %, localized corrosion resistance was recovered. The accumulated cation vacancy generates a void at metal/film interface, therefore film breakdown accelerates for cold worked alloys.

  10. Stoichiometric titanium dioxide ion implantation in AISI 304 stainless steel for corrosion protection

    Science.gov (United States)

    Hartwig, A.; Decker, M.; Klein, O.; Karl, H.

    2015-12-01

    The aim of this study is to evaluate the applicability of highly chemically inert titanium dioxide synthesized by ion beam implantation for corrosion protection of AISI 304 stainless steel in sodium chloride solution. More specifically, the prevention of galvanic corrosion between carbon-fiber reinforced plastic (CFRP) and AISI 304 was investigated. Corrosion performance of TiO2 implanted AISI 304 - examined for different implantation and annealing parameters - is strongly influenced by implantation fluence. Experimental results show that a fluence of 5 × 1016 cm-2 (Ti+) and 1 × 1017 cm-2 (O+) is sufficient to prevent pitting corrosion significantly, while galvanic corrosion with CFRP can already be noticeably reduced by an implantation fluence of 5 × 1015 cm-2 (Ti+) and 1 × 1016 cm-2 (O+). Surface roughness, implantation energy and annealing at 200 °C and 400 °C show only little influence on the corrosion behavior. TEM analysis indicates the existence of stoichiometric TiO2 inside the steel matrix for medium fluences and the formation of a separated metal oxide layer for high fluences.

  11. Martensitic Transformation during Fatigue Testing of an AISI 301LN Stainless Steel

    Science.gov (United States)

    Mateo, A.; Fargas, G.; Zapata, A.

    2012-02-01

    The plastic deformation accumulated during fatigue testing can induce the transformation of austenite to martensite in metastable austenitic stainless steels. To analyze this issue, a metastable austenitic stainless steel grade AISI 301 LN was studied in two different conditions, i.e. annealed and cold rolled. In the first case, the steel was fully austenitic, whereas cold rolled material had almost 30% of martensite. High cycle fatigue tests at a stress ratio of 0.8 were carried out on flat specimens from both steel conditions. Several characterization techniques, including optical microscopy, X-ray diffraction (XRD) and electron back scattered diffraction (EBSD), were used to detect and quantify the martensite induced by the cyclic deformation.

  12. Zircon coatings deposited by electrophoresis on steel 316L; Recubrimientos de circonia depositados por electroforesis sobre acero 316L

    Energy Technology Data Exchange (ETDEWEB)

    Espitia C, I. [Facultad de Ingenieria Quimica, UMSNH, Edificio D, C.U., 58060 Morelia, Michoacan (Mexico); Contreras G, M.E. [Instituto de Investigaciones Metalurgicas, UMSNH, Edificio U, C.U., 58060 Morelia , Michoacan (Mexico); Bartolo P, P.; Pena, J.L. [CINVESTAV-IPN, A.P. 73 Cordemex97310 Merida, Yucatan (Mexico); Reyes G, J. [IFUNAM, 01000 Mexico D.F. (Mexico); Martinez, L. [Centro de Ciencias Fisicas, UNAM, Cuernavaca, Morelos (Mexico)

    2005-07-01

    The present research involved zirconia coatings prepared using electrophoretic deposition (EPD) on 316l stainless steel, via hydrolysis of ZrOCI{sub 2} aqueous solution. Initially, a first zirconia thin film was obtained and treated at 400 C for consolidation. Then a second zirconia film was deposited to obtain a homogeneous and fully covered 316l stainless steel plate. The XPS analyses show that on the first zirconia film, the elements Fe, Cr, O and Zr are present. In this first film the compounds Cr{sub 2}O{sub 3}, Fe{sub 2}O{sub 3} and ZrO{sub 2} are formed. While in the second film only the Zr and O are observed so that the surface is formed by ZrO{sub 2}. (Author)

  13. Study of hydroxyapatite behaviour during sintering of 316L steel

    Directory of Open Access Journals (Sweden)

    A. Szewczyk-Nykiel

    2010-07-01

    Full Text Available 316L stainless steel – hydroxyapatite composite biomaterials with different hydroxyapatite weight fraction in the composite wereinvestigated. Hydroxyapatite (HAp – Ca10(PO46(OH2 is well known biomaterial. HAp reveals excellent chemical and biological affinitywith bony tissues. On the other hand hydroxyapatite shows low mechanical properties. The combination of very good biocompatibility of hydroxyapatite and high mechanical properties of stainless steel seems to be a good solution. In presented research natural originhydroxyapatite and 316L austenitic stainless steel were used. In this work, metal-ceramics composites were fabricated by the powdermetallurgy technology (involving pressing and sintering process. Sintering was carried out at 1250oC in hydrogen atmosphere. Thedensity, porosity and hardness were investigated. Metallographic microscope and SEM were carried out in order to investigate themicrostructure. The horizontal NETZSCH DIL 402E dilatometer was used to evaluate the dimensional changes and phenomena occurringduring sintering. The research displayed that physical properties of sintered 316L-HAp composites decrease with increase ofhydroxyapatite content. Microstructure of investigated composites consists of austenitic and probably inclusions of hydroxyapatite andheterogeneous eutectic occurring on the grain boundaries. It was shown that amount of hydroxyapatite in the powder mixtures influencethe dimensional changes occurring during sintering.

  14. Microstructure and Properties of Plasma Source Nitrided AISI 316 Austenitic Stainless Steel

    Science.gov (United States)

    Li, G. Y.; Lei, M. K.

    2016-11-01

    Plasma source nitriding is a relatively new nitriding technology which can overcome those inherent shortcomings associated with conventional direct current plasma nitriding technology such as the arcing surface damage, the edging effect and the hollow cathode effect. There is considerable study on the properties of nitrided samples for laboratorial scale plasma source nitriding system; however, little information has been reported on the industrial-scale plasma source nitriding system. In this work, AISI 316 austenitic stainless steel samples were nitrided by an industrial-scale plasma source nitriding system at various nitriding temperatures (350, 400, 450 and 500 °C) with a floating potential. A high-nitrogen face-centered-cubic phase (γN) formed on the surface of nitrided sample surface. As the nitriding temperature was increased, the γN phase layer thickness increased, varying from 1.5 μm for the lowest nitriding temperature of 350 °C, to 30 μm for the highest nitriding temperature of 500 °C. The maximum Vickers microhardness of the γN phase layer with a peak nitrogen concentration of 20 at.% is about HV 0.1 N 15.1 GPa at the nitriding temperature of 450 °C. The wear and corrosion experimental results demonstrated that the γN phase was formed on the surface of AISI 316 austenitic stainless steel by plasma source nitriding, which exhibits not only high wear resistance, but also good pitting corrosion resistance.

  15. 不锈钢表面Cr-Pd合金电沉积及镀层在强还原性介质中的耐蚀性%ELECTROPLATING OF Cr-Pd ALLOY ON 316L STAINLESS STEEL AND ITS CORROSION RESISFANCE IN THE STRONG REDUCING MEDIUMS

    Institute of Scientific and Technical Information of China (English)

    徐亮; 唐望磊; 左禹

    2011-01-01

    通过选择络合剂、缓冲剂及采用方波脉冲电流和优化电镀工艺,在酸性镀液中实现了Cr-Pd共镀,并在不锈钢表面制备出均匀致密且与基体结合良好的Cr-Pd合金镀层.通过改变镀液中铬盐和钯盐的相对含量,可以大范围改变镀层成分.Cr-Pd合金镀层可显著提高不锈钢在高温还原性腐蚀介质中的耐蚀性,在沸腾的20%(质量分数)H2SO4溶液中,Cr-Pd合金镀层使316L不锈钢的腐蚀速率降低了4个数量级以上.镀层中的Cr和Pd对致钝具有协同促进作用,当镀层中含有2.5%Pd(质量分数)时即具有明显的促进钝化效果,含33.3%Pd镀层对不锈钢的保护效果与纯Pd镀层相当.%By selecting complexing agent and the buffer agent, using square wave pulsed currents and optimizing electroplating process, the chromium-palladium alloy films were deposited on 316L stainless steel in acidic solution. By appropriate design for the plating bath composition and pulse electroplating, Cr-Pd alloy films were deposited on 316L stainless steel. The films were compact and homogeneous with good adherence to the substrate. By adjusting the composition of the plating bath,the ratio of Cr/Pd could be changed in a large range. The Cr-Pd films significantly improved corrosion resistance of 316L stainless steel in strong reducing mediums. In boiling 20% (mass fraction) H2SO4 solution, corrosion rates of the Cr-Pd plated samples were about four orders of magnitude lower than that of the original 316L stainless steel samples. A synergism effect was observed for Cr and Pd on passivation of stainless steel. When there was only 2.5%Pd (mass fraction) in the Cr-Pd film, corrosion resistance of the sample was obviously improved. The protection effect of Cr-33.3%Pd film was similar to that of pure Pd film on stainless steel.

  16. Complexation- and ligand-induced metal release from 316L particles: importance of particle size and crystallographic structure.

    Science.gov (United States)

    Hedberg, Yolanda; Hedberg, Jonas; Liu, Yi; Wallinder, Inger Odnevall

    2011-12-01

    Iron, chromium, nickel, and manganese released from gas-atomized AISI 316L stainless steel powders (sized 316L particles immersed in ALF. Iron was mainly released, while manganese was preferentially released as a consequence of the reduction of manganese oxide on the surface. These processes resulted in highly complexing media in a partial oxidation of trivalent chromium to hexavalent chromium on the surface. The extent of metal release was partially controlled by surface properties (e.g., availability of elements on the surface and structure of the outermost surface) and partially by the complexation capacity of the different metals with the complexing agents of the different media. In general, compared to the coarse powder (<45 μm), the fine (<4 μm) powder displayed significantly higher released amounts of metals per surface area, increased with increased solution complexation capacity, while less amounts of metals were released into non-complexing solutions. Due to the ferritic structure of lower solubility for nickel of the fine powder, more nickel was released into all solutions compared with the coarser powder.

  17. 振镜扫描激光透射连接PET薄膜与316L不锈钢薄板%Galvanometer Scanning Laser Transmission Joining between PET Films and 316L Stainless Steel

    Institute of Scientific and Technical Information of China (English)

    姜敏凤; 宋新华; 王凯; 张成; 张虎; 刘会霞

    2011-01-01

    laser transmission joining of dissimilar and biocompatible materials has potential application in biomedical implants and their encapsulation process. In this research, 0.1 nun PET films and 0.1mm 316L stainless steel are joint using galvanometer scanning laser transmission joining system. The effect of temperature on joint quality is investigated by using open-loop control and closed -loop control, the profiles of the joints were observed by optical microscopy. The process parameters windows of the laser transmission joining are obtained through open-loop control, the temperature range of getting better joint quality is analyzed by pyrometer. Using closed-loop control based on the temperature range of open-loop control, the better results can be obtained in closed-loop control of galvanometer scanning laser transmission joining system.%激光透射连接异种生物相容性材料在生物医学植入体中具有良好的应用前景.本文采用振镜扫描激光连接系统进行了0.1 mm聚对苯二甲酸乙二酯(PET)薄膜与0.1 mm 316L不锈钢薄板之间的激光透射连接试验.采用开环控制和闭环控制分析温度对连接质量的影响,使用光学显微镜对接头形貌进行观测.开环控制得到了激光透射连接过程的工艺参数窗口,并通过高温计分析出获得较好连接质量时的温度范围;在开环控制得到温度基础上采用闭环控制,所得的试验结果证明振镜扫描系统中闭环控制在激光透射连接过程中能得到更好的连接质量,更具有优势.

  18. Cracking Analysis of Nuclear Class 316L Stainless Steel Pipe with Screwed Hole for Radiographic Test%核级316L不锈钢管道射线插塞孔开裂原因分析

    Institute of Scientific and Technical Information of China (English)

    薛长江; 洪源平; 戴恒才; 操丰; 方江; 丁有元

    2016-01-01

    In order to find out the reason of cracking on one nuclear class 316L stainless steel pipe with screwed hole for radiographic test , the analyses of macrostructure/microstructure ,chemical composition ,mechanical properties ,Vickers‐hardness ,mor‐phology of fracture ,corrosion products and stress distribution of the screwed hole on the cracking pipe were done .The results show that the crack propagates along the grain boundary and the material in the fracture exhibits a rock candy pattern and a large amount of corrosion products with polygonal crystals ,which indicates that the cause of failure is attributed to inter‐granular stress corrosion cracking (IGSCC ) induced by interaction of stagnant water of pressured water reactor and material .The main reason of strain‐hardening is the interference fit between the plug and screwed hole which suffering higher welding residual stress .More non‐destructive tests on the similar struc‐ture in the in‐service NPPs and less uses in new NPPs are strongly suggested .%为查明某核电厂核级316L奥氏体不锈钢管道射线插塞孔裂纹显示的成因,对含插塞孔不锈钢管段的宏/微观形貌、化学成分、力学性能、维氏硬度、断口形貌、腐蚀产物、应力分布等进行了分析。结果表明:裂纹以沿晶方式扩展,断口呈冰糖块脆性断裂花样并伴有大量氧化腐蚀产物,属于典型的压水堆一回路水介质条件下由插塞孔局部应变‐硬化导致的晶间应力腐蚀开裂。引起应变‐硬化的主要原因是插塞孔和插塞的过盈配合以及射线插塞孔密封焊缝焊接残余应力过高。建议加强在役机组同类结构的检查,减少新建机组类似结构的使用。

  19. The effect of cladding speed on phase constitution and properties of AISI 431 stainless steel laser deposited coatings

    NARCIS (Netherlands)

    Hemmati, I.; Ocelik, V.; De Hosson, J. Th. M.

    2011-01-01

    Shorter processing time has given impetus to laser cladding technology and therefore in this research the AISI 431 martensitic stainless steel coatings are laser deposited at high cladding speeds, i.e. up to 117 mm/s. The analysis of phase constitution and functional properties of the coatings are p

  20. Extended X-Ray Absorption Fine Structure Investigation of Carbon Stabilized Expanded Austenite and Carbides in Stainless Steel AISI 316

    DEFF Research Database (Denmark)

    Oddershede, Jette; Christiansen, Thomas; Ståhl, Kenny;

    2011-01-01

    Low temperature carburized AISI 316 stainless steel - carbon expanded austenite - was investigated with EXAFS and synchrotron diffraction together with synthesized carbides of the type M3C2, M7C3 and M23C6. It was found that the chemical environment of carbon expanded austenite is not associated ...

  1. Tribological Properties of Nanometric Atomic Layer Depositions Applied on AISI 420 Stainless Steel

    Directory of Open Access Journals (Sweden)

    E. Marin

    2013-09-01

    Full Text Available Atomic Layer Deposition ( ALD is a modern technique that Allows to deposit nanometric, conformal coatings on almost any kind of substrates, from plastics to ceramic, metals or even composites. ALD coatings are not dependent on the morphology of the substrate and are only regulated by the composition of the precursors, the chamber temperature and the number of cycles. In this work, mono- and bi -layer nanometric, protective low-temperature ALD Coatings, based on Al2O3 and TiO2 were applied on AISI 420 Stainless Steel in orderto enhance its relatively low corrosion resistance in chloride containing environments. Tribological testing were also performed on the ALD coated AISI 420 in order to evaluate the wear and scratch resistance of these nanometric layers and thus evaluate their durability. Scratch tests were performed using a standard Rockwell C indenter, under a variable load condition, in order to evaluate the critical loading condition for each coating. Wear testing were performed using a stainless steel counterpart, in ball-on-discconfiguration, in order to measure the friction coefficient and wear to confront the resistance. All scratch tests scars and wear tracks were then observed by means of Scanning Electron Microscopy (SEM in order to understand the wear mechanisms that occurred on the sample surfaces. Corrosion testing, performed under immersion in 0.2 M NaCl solutions, clearly showed that the ALD coatings have a strong effect in protecting the Stainless Steel Substrate against corrosion, reducing the corrosion current density by two orders of magnitude.Tribological The preliminary results showed that ALD depositions obtained at low Temperatures have a brittle behavior caused by the amorphous nature of their structure, and thus undergo delamination phenomena during Scratch Testing at relatively low applied loads. During ball-on-disc testing, the coatings were removed from the substrate, in particular for monolayer ALD configurations

  2. OPTIMIZATION OF SURFACE ROUGHNESS OF AISI 304 AUSTENITIC STAINLESS STEEL IN DRY TURNING OPERATION USING TAGUCHI DESIGN METHOD

    Directory of Open Access Journals (Sweden)

    D. PHILIP SELVARAJ

    2010-09-01

    Full Text Available The present work is concentrated with the dry turning of AISI 304 Austenitic Stainless Steel (ASS. This paper presents the influence of cutting parameters like cutting speed, feed rate and depth of cut on the surface roughness of austenitic stainless steel during dry turning. A plan of experiments based on Taguchi’s technique has been used to acquire the data. An orthogonal array, the signal to noise (S/N ratio and the analysis of variance (ANOVA are employed to investigate the cutting characteristics of AISI 304 austenitic stainless steel bars using TiC and TiCN coated tungsten carbide cutting tool. Finally the confirmation tests that have been carried out to compare the predicted values with the experimental values confirm its effectiveness in the analysis of surface roughness.

  3. On high-cycle fatigue of 316L stents.

    Science.gov (United States)

    Barrera, Olga; Makradi, Ahmed; Abbadi, Mohammed; Azaouzi, Mohamed; Belouettar, Salim

    2014-01-01

    This paper deals with fatigue life prediction of 316L stainless steel cardiac stents. Stents are biomedical devices used to reopen narrowed vessels. Fatigue life is dominated by the cyclic loading due to the systolic and diastolic pressure and the design against premature mechanical failure is of extreme importance. Here, a life assessment approach based on the Dang Van high cycle fatigue criterion and on finite element analysis is applied to explore the fatigue reliability of 316L stents subjected to multiaxial fatigue loading. A finite element analysis of the stent vessel subjected to cyclic pressure is performed to carry out fluctuating stresses and strain at some critical elements of the stent where cracks or complete fracture may occur. The obtained results show that the loading path of the analysed stent subjected to a pulsatile load pressure is located in the safe region concerning infinite lifetime.

  4. TIG AISI-316 welds using an inert gas welding chamber and different filler metals: Changes in mechanical properties and microstructure

    Directory of Open Access Journals (Sweden)

    Sánchez, A.

    2010-12-01

    Full Text Available This report analyses the influence of the use of an inert gas welding chamber with a totally inert atmosphere on the microstructure and mechanical properties of austenitic AISI 316L stainless steel TIG welds, using AISI ER316L, AISI 308L and Inconel 625 as filler metals. When compared with the typical TIG process, the use of the inert gas chamber induced changes in the microstructure, mainly an increase in the presence of vermicular ferrite and ferrite stringers, what resulted in higher yield strengths and lower values of hardness. Its effect on other characteristics of the joins, such as tensile strength, depended on the filler metal. The best combination of mechanical characteristics was obtained when welding in the inert gas chamber using Inconel 625 as filler metal.

    En este estudio se analiza la influencia que el uso de una cámara de soldadura de gas inerte tiene sobre la microestructura y las propiedades mecánicas de las soldaduras TIG en el acero inoxidable austenítico AISI-316L cuando se emplean AISI ER316L, AISI 308L e Inconel 625 como materiales de aporte. Cuando se compara con el típico proceso de TIG, el uso de una cámara de gas inerte induce cambios en la microestructura, incrementando la presencia de ferrita vermicular y de laminillas de ferrita, resultando en un aumento del límite elástico y una pérdida de dureza. Su influencia sobre otras características de las soldaduras como la carga de rotura depende de la composición del material de aporte. La mejor combinación de propiedades mecánicas se obtuvo usando el Inconel 625 como material de aporte y soldando en la cámara de gas inerte.

  5. An Electrochemical Impedance Study of AISI 321 Stainless Steel in 0.5 M H2SO4

    Directory of Open Access Journals (Sweden)

    A. Fattah-Alhosseini

    2011-01-01

    Full Text Available The electrochemical behavior of passive films formed on AISI 321 has been examined using electrochemical impedance spectroscopy. AISI 321 is characterized by high interfacial impedance, thereby illustrating its high corrosion resistance. Results showed that the interfacial impedance and the polarization resistance initially increase with applied potential, within the low potential. However, at a sufficiently high potential (>0.6 V, the interfacial impedance and the polarization resistance decrease with increasing potential. The impedance data were adequately represented by an equivalent electrical circuit model based on point defect model, which described the behavior of the passive film on stainless steel more satisfactorily than the proposed models.

  6. Corrosion behavior of low energy, high temperature nitrogen ion-implanted AISI 304 stainless steel

    Indian Academy of Sciences (India)

    M Ghorannevis; A Shokouhy; M M Larijani; S H Haji Hosseini; M Yari; A Anvari; M Gholipur Shahraki; A H Sari; M R Hantehzadeh

    2007-01-01

    This work presents the results of a low-energy nitrogen ion implantation of AISI 304 type stainless steel (SS) at a moderate temperature of about 500° C. The nitrogen ions are extracted from a Kauffman-type ion source at an energy of 30 keV, and ion current density of 100 A cm-2. Nitrogen ion concentration of 6 × 1017, 8 × 1017 and 1018 ions cm-2, were selected for our study. The X-ray diffraction results show the formation of CrN polycrystalline phase after nitrogen bombardment and a change of crystallinity due to the change in nitrogen ion concentration. The secondary ion mass spectrometry (SIMS) results show the formation of CrN phases too. Corrosion test has shown that corrosion resistance is enhanced by increasing nitrogen ion concentration.

  7. Stress corrosion cracking of AISI 321 stainless steel in acidic chloride solution

    Indian Academy of Sciences (India)

    Yanliang Huang

    2002-02-01

    The stress corrosion cracking (SCC) of AISI 321 stainless steel in acidic chloride solution was studied by slow strain rate (SSR) technique and fracture mechanics method. The fractured surface was characterized by cleavage fracture. In order to clarify the SCC mechanism, the effects of inhibitor KI on SCC behaviour were also included in this paper. A study showed that the inhibition effects of KI on SCC were mainly attributed to the anodic reaction of the corrosion process. The results of strain distribution in front of the crack tip of the fatigue pre-cracked plate specimens in air, in the blank solution (acidic chloride solution without inhibitor KI) and in the solution added with KI measured by speckle interferometry (SPI) support the unified mechanism of SCC and corrosion fatigue cracking (CFC).

  8. Effect of Plasma Nitriding Temperatures on Characteristics of Aisi 201 Austenitic Stainless Steel

    Science.gov (United States)

    Gao, Yuxin; Zheng, Shaomei

    2016-10-01

    Samples of AISI 201 austenitic stainless steel were produced by plasma nitriding at 350∘C, 390∘C, 420∘C, 450∘C and 480∘C for 5h. Systematic characterization of the nitrided layer was carried out in terms of micrograph observations, phase identification, chemical composition depth profiling, surface microhardness measurements and electrochemical corrosion tests. The results show that the surface hardness and the layer thickness increased with increasing temperature. XRD indicated that a single S-phase layer was formed during low temperature (≤420∘C), while Cr2N or CrN phase was formed besides S-phase when nitrided at 450∘C and 480∘C. The specimen treated at 390∘C presents a much enhanced corrosion resistance compared to the untreated substrate. The corrosion resistance deteriorated for samples treated above 450∘C due to the formation of chromium nitrides.

  9. Influence of nitrogen alloying on hydrogen embrittlement in AISI 304-type stainless steels

    Energy Technology Data Exchange (ETDEWEB)

    Hannula, S.-P.; Hanninen, H.; Tahtinen, S.

    1984-12-01

    Hydrogen embrittlement of AISI 304-type austenitic stainless steels has been studied with special emphasis on the effects of the nitrogen content of the steels. Hydrogen charging was found to degrade the mechanical properties of all the steels studied, as measured by a tensile test. The fracture surfaces of hydrogen charged specimens were brittle cleavage-like whereas the uncharged specimens showed ductile, dimpled fracture. In sensitized materials transgranular cleavage mode of fracture was replaced by an intergranular mode of fracture and the losses of mechanical properties were higher. Nitrogen alloying decreased the hydrogen-induced losses of mechanical properties by increasing the stabilit of austenite. In sensitized steels the stability of austenite and nitrogen content were found to have only a minor effect on hydrogen embrittlement, except when sensitization had caused ..cap alpha..'-martensite transformation at the grain boundaries.

  10. Influence of nitrogen alloying on hydrogen embrittlement in AISI 304-type stainless steels

    Science.gov (United States)

    Hannula, Simo-Pekka; Hänninen, Hannu; Tähtinen, Seppo

    1984-12-01

    Hydrogen embrittlement of AISI 304-type austenitic stainless steels has been studied with special emphasis on the effects of the nitrogen content of the steels. Hydrogen charging was found to degrade the mechanical properties of all the steels studied, as measured by a tensile test. The fracture surfaces of hydrogen charged specimens were brittle cleavage-like whereas the uncharged specimens showed ductile, dimpled fracture. In sensitized materials transgranular cleavage mode of fracture was replaced by an intergranular mode of fracture and the losses of mechanical properties were higher. Nitrogen alloying decreased the hydrogen-induced losses of mechanical properties by increasing the stability of austenite. In sensitized steels the stability of austenite and nitrogen content were found to have only a minor effect on hydrogen embrittlement, except when sensitization had caused α'-martensite transformation at the grain boundaries.

  11. Dynamic fracture toughness and Charpy impact properties of an AISI 403 martensitic stainless steel

    Science.gov (United States)

    Sreenivasan, P. R.; Ray, S. K.; Mannan, S. L.; Rodriguez, P.

    1996-04-01

    Dynamic fracture toughness and Charpy impact properties of a normalised and tempered AISI 403 martensitic stainless steel obtained from instrumented impact tests are presented. Procedures for estimating dynamic fracture toughness ( KId) from the load-time traces obtained in instrumented tests of unprecracked Charpy V-notch (CVN) specimens are considered. The estimated KId values show reasonable agreement with those obtained from instrumented drop-weight and precracked Charpy tests. Also, except in the upper transition and uppershelf regions, the ASME KIR curve is generally conservative (i.e. gives lower KId values) when compared to the above KId estimates. The conservatism of the ASME KIR at the upper transition and uppershelf temperatures needs verification/validation. The lowest KId values estimated at the lower shelf temperatures for the above steel, namely, 33-42 MPa√m are in good agreement with the reported values of 35-50 MPa√m for the same steel in the literature.

  12. Nitrocarburizing of AISI-304 stainless steel using high-voltage plasma immersion ion implantation

    Science.gov (United States)

    Abd El-Rahman, A. M.; Mohamed, S. H.; Ahmed, M. R.; Richter, E.; Prokert, F.

    2009-05-01

    AISI-304 austenitic stainless steel has been nitrocarburized in N 2 and C 2H 2 ambient using high-voltage plasma immersion ion implantation (PIII) technology. The use of different PIII treatment times revealed important hints with respect to the microstructural, mechanical and corrosion properties of the nitrocarburized layer. Grazing incidence X-ray diffraction (GIXRD) shows the presence of nitride ( γN and CrN) and carbide ( γC and Fe 3C) phases. Glow discharge optical spectroscopy (GDOS) has been used to characterize the elemental depth profiles in which the thickness of the modified layers is derived. Dynamic microindentation method is used for the study of mechanical performance of the nitrocarburized layer as well as the untreated material. The microhardness has been increased to a maximum value of more than nine times compared to that of the untreated one. The corrosion performance is characterized by potentiodynamic polarization technique and was found to be treatment time dependent.

  13. Effect of Hydrogen and Strain-Induced Martensite on Mechanical Properties of AISI 304 Stainless Steel

    Directory of Open Access Journals (Sweden)

    Sang Hwan Bak

    2016-07-01

    Full Text Available Plastic deformation and strain-induced martensite (SIM, α′ transformation in metastable austenitic AISI 304 stainless steel were investigated through room temperature tensile tests at strain rates ranging from 2 × 10−6 to 2 × 10−2/s. The amount of SIM was measured on the fractured tensile specimens using a feritscope and magnetic force microscope. Elongation to fracture, tensile strength, hardness, and the amount of SIM increased with decreasing the strain rate. The strain-rate dependence of RT tensile properties was observed to be related to the amount of SIM. Specifically, SIM formed during tensile tests was beneficial in increasing the elongation to fracture, hardness, and tensile strength. Hydrogen suppressed the SIM formation, leading to hydrogen softening and localized brittle fracture.

  14. Effect of Carbon and Nitrogen Content on Deformation and Fracture of AISI 304 Austenitic Stainless Steel

    Directory of Open Access Journals (Sweden)

    C. Menapace

    2008-04-01

    Full Text Available The effect of small differences in the content of carbon and nitrogen on the room temperature tensile deformation and fracture behaviour of an AISI 304 stainless steel was studied. In the steel containing the lower amount of carbon and nitrogen, a higher amount of strain induced alfa’ martensite is formed, which increases strain hardening rate and both uniform and total elongation at fracture. The presence of large martensitic areas in the cross section causes strain localization at the austenite/martensite interface, which promotes the nucleation of cracks and their propagation along the interface. This results in a decrease of Ultimate Tensile Strength. Strain induced transformation slightly reduces strain rate sensitivity, as well.

  15. Surface Modification by Nitrogen Plasma Immersion Ion Implantation on Austenitic AISI 304 Stainless Steel

    Institute of Scientific and Technical Information of China (English)

    Miguel CASTRO-COLIN; William DURRER; Jorge ALPEZ; Enrique RAMIREZ-HOMS

    2016-01-01

    Surfaces of AISI 304 austenitic stainless steel plates nitrided by plasma immersion ion implantation (PIII) technology were studied by means of Auger electron spectroscopy (AES)and X-ray photoelectron spectroscopy (XPS)to determine the effect of the nitriding process on the surface and subjacent layers.Elemental compositions obtained by AES and XPS at varying depths indicate that the saturation of N is relatively constant as a function of depth,indicating the reliability of PIII technology for subsurface saturation.It is concluded that the concentrations of both Cr and O increase with depth,the subjacent oxide is driven by the Ar+ sputtering process used to access the lower layers,and then N is bound to Cr.

  16. Active flux tungsten inert gas welding of austenitic stainless steel AISI 304

    Directory of Open Access Journals (Sweden)

    D. Klobčar

    2016-10-01

    Full Text Available The paper presents the effects of flux assisted tungsten inert gas (A-TIG welding of 4 (10 mm thick austenitic stainless steel EN X5CrNi1810 (AISI 304 in the butt joint. The sample dimensions were 300 ´ 50 mm, and commercially available active flux QuickTIG was used for testing. In the planned study the influence of welding position and weld groove shape was analysed based on the penetration depth. A comparison of microstructure formation, grain size and ferrit number between TIG welding and A-TIG welding was done. The A-TIG welds were subjected to bending test. A comparative study of TIG and A-TIG welding shows that A-TIG welding increases the weld penetration depth.

  17. Microstructure and Hardness of High Temperature Gas Nitrided AISI 420 Martensitic Stainless Steel

    Directory of Open Access Journals (Sweden)

    Ibrahim Nor Nurulhuda Md.

    2014-07-01

    Full Text Available This study examined the microstructure and hardness of as-received and nitrided AISI 420 martensitic stainless steels. High temperature gas nitriding was employed to treat the steels at 1200°C for one hour and four hours using nitrogen gas, followed by furnace cooled. Chromium nitride and iron nitride were formed and concentrated at the outmost surface area of the steels since this region contained the highest concentration of nitrogen. The grain size enlarged at the interior region of the nitrided steels due to nitriding at temperature above the recrystallization temperature of the steel and followed by slow cooling. The nitrided steels produced higher surface hardness compared to as-received steel due to the presence of nitrogen and the precipitation of nitrides. Harder steel was produced when nitriding at four hours compared to one hour since more nitrogen permeated into the steel.

  18. Short-term low-temperature glow discharge nitriding of 316L austenitic steel

    Directory of Open Access Journals (Sweden)

    T. Frączek

    2011-07-01

    Full Text Available The AISI 316L austenitic steel after glow discharge nitriding at temperature of T = 673 K and duration of τ=14,4 ks, for two different variants of specimen arrangement in the glow-discharge chamber was investigated. In order to assess the effectiveness of nitriding process, the surface layers profile analysis examination, surface hardness and hardness profile examination, the analysis of surface layer structures and corrosion resistance tests were performed. It has been found that application of a booster screen effects in a nitrogen diffusion depth increment into the 316L austenitic steel surface, what results in the surface layer thickness escalation.

  19. Effect of the purging gas on properties of Ti stabilized AISI 321 stainless steel TIG welds

    Energy Technology Data Exchange (ETDEWEB)

    Taban, Emel; Kaluc, Erdinc; Aykan, T. Serkan [Kocaeli Univ. (Turkey). Dept. of Mechanical Engineering

    2014-07-01

    Gas purging is necessary to provide a high quality of stainless steel pipe welding in order to prevent oxidation of the weld zone inside the pipe. AISI 321 stabilized austenitic stainless steel pipes commonly preferred in refinery applications have been welded by the TIG welding process both with and without the use of purging gas. As purging gases, Ar, N{sub 2}, Ar + N{sub 2} and N{sub 2} + 10% H{sub 2} were used, respectively. The aim of this investigation is to detect the effect of purging gas on the weld joint properties such as microstructure, corrosion, strength and impact toughness. Macro sections and microstructures of the welds were investigated. Chemical composition analysis to obtain the nitrogen, oxygen and hydrogen content of the weld root was done by Leco analysis. Ferrite content of the beads including root and cap passes were measured by a ferritscope. Vickers hardness (HV10) values were obtained. Intergranular and pitting corrosion tests were applied to determine the corrosion resistance of all welds. Type of the purging gas affected pitting corrosion properties as well as the ferrite content and nitrogen, oxygen and hydrogen contents at the roots of the welds. Any hot cracking problems are not predicted as the weld still solidifies with ferrite in the primary phase as confirmed by microstructural and ferrite content analysis. Mechanical testing showed no significant change according to the purge gas. AISI 321 steel and 347 consumable compositions would permit use of nitrogen rich gases for root shielding without a risk of hot cracking.

  20. High temperature oxidation behavior of austenitic stainless steel AISI 304 in steam of nanofluids contain nanoparticle ZrO2

    Energy Technology Data Exchange (ETDEWEB)

    Prajitno, Djoko Hadi, E-mail: djokohp@batan.go.id; Syarif, Dani Gustaman, E-mail: djokohp@batan.go.id [Research Center for Nuclear Materials and Radiometry, Jl. Tamansari 71, Bandung 40132 (Indonesia)

    2014-03-24

    The objective of this study is to evaluate high temperature oxidation behavior of austenitic stainless steel SS 304 in steam of nanofluids contain nanoparticle ZrO{sub 2}. The oxidation was performed at high temperatures ranging from 600 to 800°C. The oxidation time was 60 minutes. After oxidation the surface of the samples was analyzed by different methods including, optical microscope, scanning electron microscope (SEM) and X-ray diffraction (XRD). X-ray diffraction examination show that the oxide scale formed during oxidation of stainless steel AISI 304 alloys is dominated by iron oxide, Fe{sub 2}O{sub 3}. Minor element such as Cr{sub 2}O{sub 3} is also appeared in the diffraction pattern. Characterization by optical microscope showed that cross section microstructure of stainless steel changed after oxidized with the oxide scale on the surface stainless steels. SEM and x-ray diffraction examination show that the oxide of ZrO{sub 2} appeared on the surface of stainless steel. Kinetic rate of oxidation of austenite stainless steel AISI 304 showed that increasing oxidation temperature and time will increase oxidation rate.

  1. Investigation of the influential parameters of machining of AISI 304 stainless steel

    Indian Academy of Sciences (India)

    R A Mahdavinejad; S Saeedy

    2011-12-01

    Austenitic stainless steels are hard materials to machine, due to their high strength, high ductility and low thermal conductivity. The last characteristic results in heat concentration at the tool cutting edge. This paper aims to optimize turning parameters of AISI 304 stainless steel. Turning tests have been performed in three different feed rates (0.2, 0.3, 0.4 mm/rev) at the cutting speeds of 100, 125, 150, 175 and 200 m/min with and without cutting fluid. A design of experiments (DOE) and an analysis of variance (ANOVA) have been made to determine the effects of each parameter on the tool wear and the surface roughness. It is being inferred that cutting speed has the main influence on the flank wear and as it increases to 175 m/min, the flank wear decreases. The feed rate has the most important influence on the surface roughness and as it decreases, the surface roughness also decreases. Also, the application of cutting fluid results in longer tool life and better surface finish.

  2. Effect of Austenitizing Heat Treatment on the Microstructure and Hardness of Martensitic Stainless Steel AISI 420

    Science.gov (United States)

    Barlow, L. D.; Du Toit, M.

    2012-07-01

    The effect of austenitizing on the microstructure and hardness of two martensitic stainless steels was examined with the aim of supplying heat-treatment guidelines to the user that will ensure a martensitic structure with minimal retained austenite, evenly dispersed carbides and a hardness of between 610 and 740 HV (Vickers hardness) after quenching and tempering. The steels examined during the course of this examination conform in composition to medium-carbon AISI 420 martensitic stainless steel, except for the addition of 0.13% vanadium and 0.62% molybdenum to one of the alloys. Steel samples were austenitized at temperatures between 1000 and 1200 °C, followed by oil quenching. The as-quenched microstructures were found to range from almost fully martensitic structures to martensite with up to 35% retained austenite after quenching, with varying amounts of carbides. Optical and scanning electron microscopy was used to characterize the microstructures, and X-ray diffraction was employed to identify the carbide present in the as-quenched structures and to quantify the retained austenite contents. Hardness tests were performed to determine the effect of heat treatment on mechanical properties. As-quenched hardness values ranged from 700 to 270 HV, depending on the amount of retained austenite. Thermodynamic predictions (using the CALPHAD™ model) were employed to explain these microstructures based on the solubility of the carbide particles at various austenitizing temperatures.

  3. Electrochemical Study of Welded AISI 304 and 904L Stainless Steel in Seawater in View of Corrosion

    Directory of Open Access Journals (Sweden)

    Richárd Székely

    2010-10-01

    Full Text Available This is a comparative study of the corrosion behaviour of welds in AISI 304 and AISI 904L stainless steels carried out in seawater model solution in the temperature range 5-35°C and the standard of corrosion testing of welds was followed. The corrosion rate and corrosion attack characteristics were determined for welds of the examined steels with several type of treatment. The aim of this work was to compare the steels based on their resistance against the corrosion in terms of pitting potential (Epit and repassivation potential (Erepass. Seawater is an electrochemically aggressive medium, which can initiate localised corrosion in welded stainless steels. Different electrochemical and testing methods were used, including cyclic voltammetry, chronopotentiometry, electrochemical impedance spectroscopy (EIS, pH measuring and penetration tests.

  4. OPTIMIZATION OF SURFACE ROUGHNESS AND TOOL FLANK WEAR IN TURNING OF AISI 304 AUSTENITIC STAINLESS STEEL WITH CVD COATED TOOL

    Directory of Open Access Journals (Sweden)

    M. KALADHAR

    2013-04-01

    Full Text Available AISI 304 austenitic stainless steel is a popularly used grade in the various fields of manufacturing because of its high ductility, high durability and excellent corrosion resistance. High work hardening, low heat conductivity and high built up edge (BUE formation made this as difficult-to- machine material. Poor surface quality and rapid tool wear are the common problems encountered while machining it. In the present work, an attempt has been made to explore the influence of machining parameters on the performance measures, surface roughness and flank wear in turning of AISI 304 austenitic stainless steel with a two layer Chemical vapour deposition(CVD coated tool. In order to achieve this, Taguchi approach has been employed. The results revealed that the cutting speed most significantly, influences both surface roughness and flank wear. In addition to this the optimal setting of process parameters and optimal ranges of performance measures are predicted.

  5. LaCrO3 composite coatings for AISI 444 stainless steel solid oxide fuel cell interconnects

    Directory of Open Access Journals (Sweden)

    Wilson Acchar

    2012-12-01

    Full Text Available Doped lanthanum chromite-based ceramics are the most widely used interconnector material in solid fuel cells (SOFC since they exhibit significant electrical and thermal conductivity, substantial corrosion resistance and adequate mechanical strength at ambient and high temperatures. The disadvantage of this material is its high cost and poor ductility. The aim of this study is to determine the mechanical and oxidation behavior of a stainless steel (AISI 444 with a LaCrO3 deposition on its surface obtained through spray pyrolisis. Coated and pure AISI 444 materials were characterized by mechanical properties, oxidation behavior, X-ray diffraction and scanning electronic microscopy. Results indicated that the coated material displays better oxidation behavior in comparison to pure stainless steel, but no improvement in mechanical strength. Both materials indicate that deformation behavior depends on testing temperatures.

  6. 炼油加工过程中氯离子与硫离子对316L不锈钢和Monel合金腐蚀的影响%Effect of Chlorine Ion and Sulfur Ion on Corrosion of 316 L Stainless Steel and Monel Alloy in Oil Refining Process

    Institute of Scientific and Technical Information of China (English)

    孙亮; 侯艳宏; 杨席; 张志恒; 朱元强; 王虎; 唐鋆磊

    2015-01-01

    Objective To investigate the influences of contents of chloride and sulfur ions on corrosion rates of 316L stainless steel and nickel-based alloy Monel in crude oil fractions and overhead aqueous phase of crude oil unit. Methods The corrosion rates of 316L stainless steel and Monel alloy in aqueous phase and oil phase containing different concentrations of chloride ions and sulfur ions were obtained by corrosion coupon experiment. SEM ( scanning electron microscope) was used to observe the surface microstructure of corroded 316L and Monel alloys. The influence of two kinds of ions on the corrosion of 316L stainless steel and Monel alloy was discussed. Results The corrosion rates of 316L stainless steel and Monel alloy in highly acidic desalted crude oil were 0. 0091 mm/a and 0. 0248 mm/a, respectively. And in weak acidic second fraction, the corrosion rates were 0. 0078 mm/a and 0. 0031 mm/a, respectively. In second fraction, after addition of 600 mg/L of chlorine ion and 30 mg/L of sodium sulfide, the corrosion rates of 316L stainless steel and Monel alloy were 0. 1755mm/a and 0. 1707 mm/a, respectively. Meanwhile, in the de-salted crude oil with the same concentrations of chloride ions and sulfide ions, the corrosion rate of 316L stainless steel was 0. 0545 mm/a and that of Monel alloy was 0. 1281 mm/a. Conclusion The results indicated that the naphthenic acid corrosion was the dominant factor when there was little chloride in oil phase and the chloride corrosion turned into the major factor if the content of chloride in oil was at high levels. The corrosion rates of the 316L stainless and Monel alloy raised with the increase of chloride ion concentration in oil phase. Furthermore, the existence of sulfur ions could accelerate corrosion in oil phase. In contrast, chloride and sulfur ions did not have apparent impact on the corrosion of Monel alloy in aqueous phase.%目的 研究常减压装置高温原油馏分及塔顶水相中氯离子、硫离子含量对316

  7. Modification and characterization of the AISI 410 martensitic stainless steels surface; Modificacao e caracterizacao da superficie do aco inoxidavel martensitico AISI 410

    Energy Technology Data Exchange (ETDEWEB)

    Bincoleto, A.V.L. [Universidade Federal de Sao Carlos (PPG-CEM/UFSCar), SP (Brazil). Programa de Pos-Graduacao em Ciencia e Engenharia de Materiais; Nascente, P.A.P. [Universidade Federal de Sao Carlos (DEMa/UFSCar), SP (Brazil). Dept. de Engenharia de Materiais

    2010-07-01

    Steam turbines are used in the generation of more than half the electric energy produced in the world nowadays. It is important the study which aims to improve the efficiency by means of the optimization of leaks and of the aerodynamic profiles, as well as to maintain the integrity of the components. The martensitic stainless steels are widely employed due to the combination of their good mechanical properties with higher corrosion resistance. However, their lower wear resistance and their poor tribological behavior limit their use, since they decrease the component life time. In order to evaluate the improvement in the performance of the AISI 410 stainless steel, several process of surface modification were employed. Five samples were produced: the first one was not treated, the second one received liquid nitriding, the third, gas nitriding, the forth, thermal aspersion of tungsten carbide, and the fifth, boronizing. The samples were characterized by optical microscopy, surface microhardness, and X-ray diffractometry. (author)

  8. Texture analysis of deformation induced martensite in an AISI 301L stainless steel: microtexture and macrotexture aspects

    OpenAIRE

    Hamilton Ferreira Gomes de Abreu; Marcelo José Gomes da Silva; Luís Flávio Gaspar Herculano; Harry Bhadeshia

    2009-01-01

    Experiments have been conducted to study the strain induced transformation from austenite to martensite in a metastable AISI 301LN austenitic stainless steel, deformed by uniaxial tension applied along rolling direction. Samples deformed 10 and 20% have shown the presence of α´ martensite phase. Measured pole figures of martensite phase were compared to calculated ones, assuming no variant selection and selection of variants where interaction between stress and the plate of martensite ad...

  9. Surface modification of investment cast-316L implants: microstructure effects.

    Science.gov (United States)

    El-Hadad, Shimaa; Khalifa, Waleed; Nofal, Adel

    2015-03-01

    Artificial femur stem of 316L stainless steel was fabricated by investment casting using vacuum induction melting. Different surface treatments: mechanical polishing, thermal oxidation and immersion in alkaline solution were applied. Thicker hydroxyapatite (HAP) layer was formed in the furnace-oxidized samples as compared to the mechanically polished ones. The alkaline treatment enhanced the precipitation of HAP on the samples. It was also observed that the HAP precipitation responded differently to the different phases of the microstructure. The austenite phase was observed to have more homogeneous and smoother layer of HAP. In addition, the growth of HAP was sometimes favored on the austenite phase rather than on ferrite phase.

  10. OPTIMIZATION OF SURFACE ROUGHNESS OF AISI 304 AUSTENITIC STAINLESS STEEL IN DRY TURNING OPERATION USING TAGUCHI DESIGN METHOD

    OpenAIRE

    D. PHILIP SELVARAJ; Chandramohan, P.

    2010-01-01

    The present work is concentrated with the dry turning of AISI 304 Austenitic Stainless Steel (ASS). This paper presents the influence of cutting parameters like cutting speed, feed rate and depth of cut on the surface roughness of austenitic stainless steel during dry turning. A plan of experiments based on Taguchi’s technique has been used to acquire the data. An orthogonal array, the signal to noise (S/N) ratio and the analysis of variance (ANOVA) are employed to investigate the cutting cha...

  11. Evaluation of structural behaviour and corrosion resistant of austenitic AISI 304 and duplex AISI 2304 stainless steel reinforcements embedded in ordinary Portland cement mortars; Evaluacion del comportamiento estructural y de resistencia a la corrosion de armaduras de acero inoxidable austenitico AISI 304 y duplex AISI 2304 embebidas en morteros de cemento Portland

    Energy Technology Data Exchange (ETDEWEB)

    Medina, E.; Cobo, A.; Bastidas, D. M.

    2012-07-01

    The mechanical and structural behaviour of two stainless steels reinforcements, with grades austenitic EN 1.4301 (AISI 304) and duplex EN 1.4362 (AISI 2304) have been studied, and compared with the conventional carbon steel B500SD rebar. The study was conducted at three levels: at rebar level, at section level and at structural element level. The different mechanical properties of stainless steel directly influence the behaviour at section level and structural element level. The study of the corrosion behaviour of the two stainless steels has been performed by electrochemical measurements, monitoring the corrosion potential and the lineal polarization resistance (LPR), of reinforcements embedded in ordinary Portland cement (OPC) mortar specimens contaminated with different amount of chloride over one year time exposure. Both stainless steels specimens embedded in OPC mortar remain in the passive state for all the chloride concentration range studied after one year exposure. (Author) 26 refs.

  12. Wear Characteristics of Ni-Based Hardfacing Alloy Deposited on Stainless Steel Substrate by Laser Cladding

    Science.gov (United States)

    Awasthi, Reena; Limaye, P. K.; Kumar, Santosh; Kushwaha, Ram P.; Viswanadham, C. S.; Srivastava, Dinesh; Soni, N. L.; Patel, R. J.; Dey, G. K.

    2015-03-01

    In this study, dry sliding wear characteristics of the Ni-based hardfacing alloy (Ni-Mo-Cr-Si) deposited on stainless steel SS316L substrate by laser cladding have been presented. Dry sliding wear behavior of the laser clad layer was evaluated against two different counter bodies, AISI 52100 chromium steel (~850 VHN) and tungsten carbide ball (~2200 VHN) to study both adhesive and abrasive wear characteristics, in comparison with the substrate SS316L using ball on plate reciprocating wear tester. The wear resistance was evaluated as a function of load and sliding speed for a constant sliding amplitude and sliding distance. The wear mechanisms were studied on the basis of wear surface morphology and microchemical analysis of the wear track using SEM-EDS. Laser clad layer of Ni-Mo-Cr-Si on SS316L exhibited much higher hardness (~700 VHN) than that of substrate SS316L (~200 VHN). The laser clad layer exhibited higher wear resistance as compared to SS316L substrate while sliding against both the counterparts. However, the improvement in the wear resistance of the clad layer as compared to the substrate was much higher while sliding against AISI 52100 chromium steel than that while sliding against WC, at the same contact stress intensity.

  13. Investigation of AISI 441 Ferritic Stainless Steel and Development of Spinel Coatings for SOFC Interconnect Applications

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Zhenguo; Xia, Guanguang; Wang, Chong M.; Nie, Zimin; Templeton, Joshua D.; Singh, Prabhakar; Stevenson, Jeffry W.

    2008-05-30

    As part of an effort to develop cost-effective ferritic stainless steel-based interconnects for solid oxide fuel cell (SOFC) stacks, both bare and spinel coated AISI 441 were studied in terms of metallurgical characteristics, oxidation behavior, and electrical performance. The conventional melt metallurgy used for the bulk alloy fabrication leads to significant processing cost reduction and the alloy chemistry with the presence of minor alloying additions of Nb and Ti facilitate the strengthening by precipitation and formation of Laves phase both inside grains and along grain boundaries during exposure in the intermediate SOFC operating temperature range. The Laves phase formed along the grain boundaries also ties up Si and prevents the formation of an insulating silica layer at the scale/metal interface during prolonged exposure. The substantial increase in ASR during long term oxidation due to oxide scale growth suggested the need for a conductive protection layer, which could also minimize Cr evaporation. In particular, Mn1.5Co1.5O4 based surface coatings on planar coupons drastically improved the electrical performance of the 441, yielding stable ASR values at 800ºC for over 5,000 hours. Ce-modified spinel coatings retained the advantages of the unmodified spinel coatings, and also appeared to alter the scale growth behavior beneath the coating, leading to a more adherent scale. The spinel protection layers appeared also to improve the surface stability of 441 against the anomalous oxidation that has been observed for ferritic stainless steels exposed to dual atmosphere conditions similar to SOFC interconnect environments. Hence, it is anticipated that, compared to unmodified spinel coatings, the Ce-modified coatings may lead to superior structural stability and electrical performance.

  14. Wear and Corrosion Study of Sputtered Zirconium thin films on SS316L for Windmill Application

    Directory of Open Access Journals (Sweden)

    Arunkumar N

    2015-05-01

    Full Text Available The Aim of this study is to observe the Wear and Corrosion behavior of Zirconium coated 316L stainless steel. After polishing, SS316L was coated with Zirconium employing DC sputtering process (a technique of physical vapor deposition.Structure characterization techniques including Scanning Electron Microscope (SEM and X-Ray Diffraction (XRD were utilized to investigate the microstructure and crystallinity of the coating. Salt spray test was performed by spraying Sodium chloride in order to determine corrosion resistance behavior of the coated sample. Pin on disc wear test was performed by hardened and tempered EN31 steel pin in order to determine and compare the Wear resistance behavior of Coated and uncoated samples. The Objective is to recommend the zirconium coated Stainless steel SS316L can be a choice for Off-shore wind mills where the shafts undergo Wear and corrosion problems.

  15. Microstructure analysis of AISI 304 stainless steel produced by twin-roll thin strip casting process

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    The microstructure of AISI 304 austenite stainless steel fabricated by the thin strip casting process were investigated using optical microscope, scanning electron microscope (SEM), transmission electron microscope (TEM), and X-ray diffraction (XRD).The microstructures of the casting strips show a duplex structure consisting of delta ferrite and austenite. The volume fraction of the delta ferrite is about 9.74vol% at the center and 6.77vol% at the surface of the casting thin strip, in vermicular and band shapes. On account of rapid cooling and solidification in the continuous casting process, many kinds of inclusions and precipitates have been found. Most of the inclusions and precipitates are spherical complex compounds consisting of oxides, such as, SiO2, MnO, Al2O3,Cr2O3,and FeO or their multiplicity oxides of MnO·Al2O3,2FeO·SiO2, and 2MnO·SiO2. Many defects including dislocations and stacking faults have also formed during the rapid cooling and solidification process, which is helpful to improve the mechanical properties of the casting strips.

  16. Thermodynamic modeling and kinetics simulation of precipitate phases in AISI 316 stainless steels

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Y., E-mail: yangying@ornl.gov [Materials Science and Technology Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States); Busby, J.T. [Fusion and Materials for Nuclear Systems Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States)

    2014-05-01

    This work aims at utilizing modern computational microstructural modeling tools to accelerate the understanding of phase stability in austenitic steels under extended thermal aging. Using the CALPHAD approach, a thermodynamic database OCTANT (ORNL Computational Thermodynamics for Applied Nuclear Technology), including elements of Fe, C, Cr, Ni, Mn, Mo, Si, and Ti, has been developed with a focus on reliable thermodynamic modeling of precipitate phases in AISI 316 austenitic stainless steels. The thermodynamic database was validated by comparing the calculated results with experimental data from commercial 316 austenitic steels. The developed computational thermodynamics was then coupled with precipitation kinetics simulation to understand the temporal evolution of precipitates in austenitic steels under long-term thermal aging (up to 600,000 h) at a temperature regime from 300 to 900 °C. This study discusses the effect of dislocation density and difusion coefficients on the precipitation kinetics at low temperatures, which shed a light on investigating the phase stability and transformation in austenitic steels used in light water reactors.

  17. Finite Element Simulation of Residual Stresses in Butt Welding of Two AISI 304 Stainless Steel Plates

    Directory of Open Access Journals (Sweden)

    Gurinder Singh Brar

    2013-06-01

    Full Text Available Welding is one of the most reliable and efficient permanent metal joining processes in the industry. When two plates are joined by welding, a very complex thermal cycle is applied to the weldment. Thermal energy applied results in irreversible elastic-plastic deformation and consequently gives rise to the residual stresses in and around fusion zone and heat affected zone (HAZ. It is well established fact that structural integrity of components is substantially affected by the residual stresses when subjected to thermal and structural loads. Presence of residual stresses may be beneficial or harmful for the structural components depending on the nature and magnitude of residual stresses. Using finite element based commercially available software, coupled thermal-mechanical three dimensional finite element model was developed by making an approximate geometry of the butt welded joint. Finite element analysis was performed to understand the complete nature of residual stresses in manual metal arc welded joint of AISI 304 stainless steel plate. Variation of residual stress in the plates in the heat affected zone was also being studied. The results obtained by finite element method agree well with those from X-ray diffraction method as published in literature for the prediction of residual stresses.

  18. Parametric optimization during machining of AISI 304 Austenitic Stainless Steel using CVD coated DURATOMIC cutting insert

    Directory of Open Access Journals (Sweden)

    M. Kaladhar

    2012-08-01

    Full Text Available In this work, Taguchi method is applied to determine the optimum process parameters for turning of AISI 304 austenitic stainless steel on CNC lathe. A Chemical vapour deposition (CVD coated cemented carbide cutting insert is used which is produced by DuratomicTM technology of 0.4 and 0.8 mm nose radii. The tests are conducted at four levels of Cutting speed, feed and depth of cut. The influence of these parameters are investigated on the surface roughness and material removal rate (MRR. The Analysis Of Variance (ANOVA is also used to analyze the influence of cutting parameters during machining. The results revealed that cutting speed significantly (46.05% affected the machined surface roughness values followed by nose radius (23.7%. The influence of the depth of cut (61.31% in affecting material removal rate (MRR is significantly large. The cutting speed (20.40% is the next significant factor. Optimal range and optimal level of parameters are also predicted for responses.

  19. Influence of gas pressure and substrate temperature on PIII nitrocarburizing process of AISI 304 stainless steel

    Energy Technology Data Exchange (ETDEWEB)

    Abd El-Rahman, A.M. [Physics Department, Faculty of Science, South Valley University, Sohag Branch, Sohag (Egypt) and Institute of Ion Beam Physics and Material Research, FWII, Forschungszentrum Rossendorf, 01314 Dresden (Germany)]. E-mail: ahmedphys96@hotmail.com; El-Hossary, F.M. [Physics Department, Faculty of Science, South Valley University, Sohag Branch, Sohag (Egypt); Negm, N.Z. [Physics Department, Faculty of Science, South Valley University, Sohag Branch, Sohag (Egypt); Prokert, F. [Institute of Ion Beam Physics and Material Research, FWII, Forschungszentrum Rossendorf, 01314 Dresden (Germany); Richter, E. [Institute of Ion Beam Physics and Material Research, FWII, Forschungszentrum Rossendorf, 01314 Dresden (Germany); Moeller, W. [Institute of Ion Beam Physics and Material Research, FWII, Forschungszentrum Rossendorf, 01314 Dresden (Germany)

    2004-12-01

    Plasma immersion ion implantation (PIII) has been used to modify the surface properties of 304 austenitic stainless steel (AISI). The influence of working gas pressure, 0.2-1.0 Pa, and substrate temperature, 300-500 deg. C, on the microstructure, treating rate, nitrogen/carbon concentration depth profile, and surface microhardness was investigated. A gas composition of 25% C{sub 2}H{sub 2}, 75% N{sub 2}, r.f. plasma power input of 350 W, and a negatively biased potential of 30 kV were fixed during the experiment. The experimental results show that the substrate temperature and the diffusion process of nitrogen and carbon depend on the gas pressure inside the plasma chamber. The thickness of the modified layer has been found to be more than 30 {mu}m for samples were treated in the plasma for 60 min. The results show also that the values of diffusion coefficient and surface microhardness of the treated samples are high to be 3.4 x 10{sup -1} {mu}m{sup 2}/s and 1880 kg/mm{sup 2}, respectively.

  20. Influence of gas pressure and substrate temperature on PIII nitrocarburizing process of AISI 304 stainless steel

    Science.gov (United States)

    Abd El-Rahman, A. M.; El-Hossary, F. M.; Negm, N. Z.; Prokert, F.; Richter, E.; Möller, W.

    2004-12-01

    Plasma immersion ion implantation (PIII) has been used to modify the surface properties of 304 austenitic stainless steel (AISI). The influence of working gas pressure, 0.2-1.0 Pa, and substrate temperature, 300-500 °C, on the microstructure, treating rate, nitrogen/carbon concentration depth profile, and surface microhardness was investigated. A gas composition of 25% C2H2, 75% N2, r.f. plasma power input of 350 W, and a negatively biased potential of 30 kV were fixed during the experiment. The experimental results show that the substrate temperature and the diffusion process of nitrogen and carbon depend on the gas pressure inside the plasma chamber. The thickness of the modified layer has been found to be more than 30 μm for samples were treated in the plasma for 60 min. The results show also that the values of diffusion coefficient and surface microhardness of the treated samples are high to be 3.4 × 10-1 μm2/s and 1880 kg/mm2, respectively.

  1. Nitrocarburizing of AISI-304 stainless steel using high-voltage plasma immersion ion implantation

    Energy Technology Data Exchange (ETDEWEB)

    Abd El-Rahman, A.M. [Physics Department, Faculty of Science, Sohag University, 82524 Sohag (Egypt)], E-mail: ahmedphys96@hotmail.com; Mohamed, S.H.; Ahmed, M.R. [Physics Department, Faculty of Science, Sohag University, 82524 Sohag (Egypt); Richter, E.; Prokert, F. [Institut fuer Ionenstrahlphysik und Materialforschung, Forschungszentrum Dresden Rossendorf (Germany)

    2009-05-15

    AISI-304 austenitic stainless steel has been nitrocarburized in N{sub 2} and C{sub 2}H{sub 2} ambient using high-voltage plasma immersion ion implantation (PIII) technology. The use of different PIII treatment times revealed important hints with respect to the microstructural, mechanical and corrosion properties of the nitrocarburized layer. Grazing incidence X-ray diffraction (GIXRD) shows the presence of nitride ({gamma}{sub N} and CrN) and carbide ({gamma}{sub C} and Fe{sub 3}C) phases. Glow discharge optical spectroscopy (GDOS) has been used to characterize the elemental depth profiles in which the thickness of the modified layers is derived. Dynamic microindentation method is used for the study of mechanical performance of the nitrocarburized layer as well as the untreated material. The microhardness has been increased to a maximum value of more than nine times compared to that of the untreated one. The corrosion performance is characterized by potentiodynamic polarization technique and was found to be treatment time dependent.

  2. Enhanced mechanical properties of type AISI301LN austenitic stainless steel through advanced thermo mechanical process

    Energy Technology Data Exchange (ETDEWEB)

    Huang Junxia, E-mail: huangjunxia@baosteel.com [Shanghai Baosteel Research Institute, Shanghai 200431 (China); Ye Xiaoning; Gu Jiaqing; Chen Xu [Shanghai Baosteel Research Institute, Shanghai 200431 (China); Xu Zhou [School of Material Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240 (China)

    2012-01-15

    Highlights: Black-Right-Pointing-Pointer 69% of strain induced martensite were obtained after 80% thickness reduction at 0 Degree-Sign C. Black-Right-Pointing-Pointer The best annealing regime was determined for diffusional controlled reversion. Black-Right-Pointing-Pointer The effect of grain size on mechanical properties conforms with the H-P relationship. - Abstract: The effect of annealing temperature and time on the grain size of reversed austenite and mechanical properties was studied based on AISI301LN austenitic stainless steel in this paper. Cold rolling at 0 Degree-Sign C was employed to obtain the strain-induced martensite, followed by annealing treatment at the temperature range of 650-900 Degree-Sign C for 1-20 min. The relationship between the volume fraction of strain-induced martensite and cold reduction was analyzed by Ferritescope MP30 and X-ray diffraction. The grain growth of reversed austenite was observed by FEG-SEM and the mechanical properties were determined by tensile tests and Vickers hardness tests. Austenite grain sizes under 3 {mu}m can be obtained after annealing in the range of 700-900 Degree-Sign C for 1-20 min. The finest austenite grain size was produced after annealing at 700 Degree-Sign C for 20 min, which had a good combination of yield strength ( Almost-Equal-To 830 MPa), tensile strength ( Almost-Equal-To 953 MPa) and elongation ( Almost-Equal-To 36%).

  3. Welding of AA1050 aluminum with AISI 304 stainless steel by rotary friction welding process

    Directory of Open Access Journals (Sweden)

    Chen Ying An

    2010-09-01

    Full Text Available The purpose of this work was to assess the development of solid state joints of dissimilar material AA1050 aluminum and AISI 304 stainless steel, which can be used in pipes of tanks of liquid propellants and other components of the Satellite Launch Vehicle. The joints were obtained by rotary friction welding process (RFW, which combines the heat generated from friction between two surfaces and plastic deformation. Tests were conducted with different welding process parameters. The results were analyzed by means of tensile tests, Vickers microhardness, metallographic tests and SEM-EDX. The strength of the joints varied with increasing friction time and the use of different pressure values. Joints were obtained with superior mechanical properties of the AA1050 aluminum, with fracture occurring in the aluminum away from the bonding interface. The analysis by EDX at the interface of the junction showed that interdiffusion occurs between the main chemical components of the materials involved. The RFW proves to be a great method for obtaining joints between dissimilar materials, which is not possible by fusion welding processes.

  4. Aluminum coating by fluidized bed chemical vapor deposition on austenitic stainless steels AISI 304 and AISI 316

    Directory of Open Access Journals (Sweden)

    Jose Luddey Marulanda-Arevalo

    2015-01-01

    Full Text Available Los revestimientos de aluminio f ueron depositados sobre aceros inoxidables AISI 304 y AISI 316 en el rango de temperatura de 5 60 a 600 °C por deposición química de vapor en lecho fluidizado(CVD – FBR. Se utilizó un lecho que consistía en 10 % de aluminio en polvo y 90 % de lecho inerte (alúmina, el cual fue fluidizado con Ar y como ga ses activadores se utilizó una mezcla de ácido clorhídrico con hidrógeno (HCl/H 2 . En el recubrimiento si n tratamiento térmico están las siguiente s especies: Al 13 Fe 4 , Fe 2 Al 5 , FeAl 2 y Al 5 FeNi, las cuales están presentes para ambos aceros. Además, el tratamiento térmico provoca la difusa de alu minio hacia el sustrato y la difusa de hierro del sustrato haci a la superficie del recubrimiento, haciendo la trans formación de los compuestos ant eriores a FeAl, Fe 2 Al 5 , FeAl 2 , Al 0.99 Fe 0.99 Ni 0.02 , AlNi y el Fe 2 AlCr. Se realizó la simulación termodinámica con el s oftware Thermo Calc para obt ener información de la posible composición y la cantidad de mat erial depositado, para condiciones seleccionadas. Las muestras recubi ertas y sin recubrir, se expus ieron a 750 ºC en una atmósfera d onde el vapor agua se transporta a las muestras usando un flujo de N 2 de 40 ml/min, más 100 % vapor de agua (H 2 O. Los dos sustratos sin revestir se comportaron de manera diferente, ya que el acero AISI 304 soportó bien el a taque y ganó poco peso (0.49 mg/cm 2 , en comparación con el acero AISI 316 que perdió mucho peso (25.4 mg/cm 2 . Los aceros recubiertos ganaron poco de peso durante las mil horas de exposición (0.26 mg/cm 2 y soportaron muy bien el ataque corrosivo en c omparación con sustratos sin r ecubrimiento.

  5. Surface Texturing-Plasma Nitriding Duplex Treatment for Improving Tribological Performance of AISI 316 Stainless Steel

    Directory of Open Access Journals (Sweden)

    Naiming Lin

    2016-10-01

    Full Text Available Surface texturing-plasma nitriding duplex treatment was conducted on AISI 316 stainless steel to improve its tribological performance. Tribological behaviors of ground 316 substrates, plasma-nitrided 316 (PN-316, surface-textured 316 (ST-316, and duplex-treated 316 (DT-316 in air and under grease lubrication were investigated using a pin-on-disc rotary tribometer against counterparts of high carbon chromium bearing steel GCr15 and silicon nitride Si3N4 balls. The variations in friction coefficient, mass loss, and worn trace morphology of the tested samples were systemically investigated and analyzed. The results showed that a textured surface was formed on 316 after electrochemical processing in a 15 wt % NaCl solution. Grooves and dimples were found on the textured surface. As plasma nitriding was conducted on a 316 substrate and ST-316, continuous and uniform nitriding layers were successfully fabricated on the surfaces of the 316 substrate and ST-316. Both of the obtained nitriding layers presented thickness values of more than 30 μm. The nitriding layers were composed of iron nitrides and chromium nitride. The 316 substrate and ST-316 received improved surface hardness after plasma nitriding. When the tribological tests were carried out under dry sliding and grease lubrication conditions, the tested samples showed different tribological behaviors. As expected, the DT-316 samples revealed the most promising tribological properties, reflected by the lowest mass loss and worn morphologies. The DT-316 received the slightest damage, and its excellent tribological performance was attributed to the following aspects: firstly, the nitriding layer had high surface hardness; secondly, the surface texture was able to capture wear debris, store up grease, and then provide continuous lubrication.

  6. Fatigue life improvements of the AISI 304 stainless steel ground surfaces by wire brushing

    Science.gov (United States)

    Ben Fredj, Nabil; Ben Nasr, Mohamed; Ben Rhouma, Amir; Sidhom, Habib; Braham, Chedly

    2004-10-01

    The surface and subsurface integrity of metallic ground components is usually characterized by an induced tensile residual stress, which has a detrimental effect on the fatigue life of these components. In particular, it tends to accelerate the initiation and growth of the fatigue cracks. In this investigation, to deliberately generate compressive residual stresses into the ground surfaces of the AISI 304 stainless steel (SS), wire brushing was applied. It was found that under the experimental conditions selected in this investigation, while the surface roughness was slightly improved by the brushing process, the surface residual stress shifted from a tensile stress (σ‖=+450 MPa) to a compressive stress (σ‖=-435 MPa). On the other hand, the work-hardened deformation layer was almost two times deeper after wire brushing. Concerning the fatigue life, an improvement of 26% in terms of endurance limit at 2×106 cycles was realized. Scanning electron microscope (SEM) observations of the fatigue fracture location and size were carried out to explain the fatigue life improvement. It was found that the enhancement of the fatigue strength could be correlated with the distribution and location of the fatigue fracture nucleation sites. Concerning the ground surfaces, it was seen that the fatigue cracks initiated at the bottom of the grinding grooves and were particularly long (150-200 µm). However, the fatigue cracks at the brushed surfaces were shorter (20-40 µm) and appeared to initiate sideways to the plowed material caused by the wire brushing. The results of the wire-brushed surface characterization have shown that significant advantages can be realized regarding surface integrity by the application of this low-cost process compared to shot peening.

  7. Comparative study of pulsed Nd:YAG laser welding of AISI 304 and AISI 316 stainless steels

    Science.gov (United States)

    Kumar, Nikhil; Mukherjee, Manidipto; Bandyopadhyay, Asish

    2017-02-01

    Laser welding is a potentially useful technique for joining two pieces of similar or dissimilar materials with high precision. In the present work, comparative studies on laser welding of similar metal of AISI 304SS and AISI 316SS have been conducted forming butt joints. A robotic control 600 W pulsed Nd:YAG laser source has been used for welding purpose. The effects of laser power, scanning speed and pulse width on the ultimate tensile strength and weld width have been investigated using the empirical models developed by RSM. The results of ANOVA indicate that the developed models predict the responses adequately within the limits of input parameters. 3-D response surface and contour plots have been developed to find out the combined effects of input parameters on responses. Furthermore, microstructural analysis as well as hardness and tensile behavior of the selected weld of 304SS and 316SS have been carried out to understand the metallurgical and mechanical behavior of the weld. The selection criteria are based on the maximum and minimum strength achieved by the respective weld. It has been observed that the current pulsation, base metal composition and variation in heat input have significant influence on controlling the microstructural constituents (i.e. phase fraction, grain size etc.). The result suggests that the low energy input pulsation generally produce fine grain structure and improved mechanical properties than the high energy input pulsation irrespective of base material composition. However, among the base materials, 304SS depict better microstructural and mechanical properties than the 316SS for a given parametric condition. Finally, desirability function analysis has been applied for multi-objective optimization for maximization of ultimate tensile strength and minimization of weld width simultaneously. Confirmatory tests have been conducted at optimum parametric conditions to validate the optimization techniques.

  8. An evaluation of microbial growth and corrosion of 316L SS in glycol/seawater mixtures

    Science.gov (United States)

    Lee, Jason S.; Ray, Richard I.; Lowe, Kristine L.; Jones-Meehan, Joanne; Little, Brenda J.

    2003-01-01

    Glycol/seawater mixtures containing > 50% glycol inhibit corrosion of 316L stainless steel and do not support bacterial growth. The results indicate bacteria are able to use low concentrations of glycol (10%) as a growth medium, but bacterial growth decreased with increasing glycol concentration. Pitting potential, determined by anodic polarization, was used to evaluate susceptibility of 316L SS to corrosion in seawater-contaminated glycol. Mixture containing a minimum concentration of 50% propylene glycol-based coolant inhibited pitting corrosion. A slightly higher minimum concentration (55%) was needed for corrosion protection in ethylene glycol mixtures.

  9. Formation of amorphous Ti alloy layers by excimer laser mixing of Ti on AISI 304 stainless-steel surfaces

    Science.gov (United States)

    Jervis, T. R.; Nastasi, M.; Zocco, T. G.; Martin, J. A.

    1988-07-01

    We used excimer laser radiation at 308 nm to mix thin layers of Ti into AISI 304 stainless steel. Different numbers of shots at a fluence about twice the threshold for melting varied the amount of mixing. When mixing is sufficiently complete, an amorphous surface layer is formed with Ti substituting for Fe on a one-to-one basis in the alloy. The laser mixing process, unlike Ti ion implantation, does not result in high incorporation of C in the processed layer, although some C from surface and interface contamination is incorporated into the surface layer.

  10. Effect of martensite to austenite reversion on the formation of nano/submicron grained AISI 301 stainless steel

    Energy Technology Data Exchange (ETDEWEB)

    Karimi, M.; Najafizadeh, A. [Department of Materials Engineering, Isfahan University of Technology, Isfahan 84156-83111 (Iran, Islamic Republic of); Kermanpur, A., E-mail: ahmad_k@cc.iut.ac.ir [Department of Materials Engineering, Isfahan University of Technology, Isfahan 84156-83111 (Iran, Islamic Republic of); Eskandari, M. [Department of Materials Engineering, Isfahan University of Technology, Isfahan 84156-83111 (Iran, Islamic Republic of)

    2009-11-15

    The martensite to austenite reversion behavior of 90% cold rolled AISI 301 stainless steel was investigated in order to refine the grain size. Cold rolled specimens were annealed at 600-900 deg. C, and subsequently characterized by scanning electron microscopy, X-ray diffraction, Feritscope, and hardness measurements. The effects of annealing parameters on the formation of fully-austenitic nano/submicron grained structure and the mechanisms involved were studied. It was found that annealing at 800 deg. C for 10 s exhibited the smallest average austenite grain size of 240 {+-} 60 nm with an almost fully-austenitic structure.

  11. Effect of Cl– on the corrosive wear of AISI 321 stainless steel in H2SO4 solution

    Indian Academy of Sciences (India)

    Yanliang Huang; Xiaoxia Jiang; Sizuo Li

    2003-06-01

    The effect of Cl– on the corrosive wear behaviour of AISI 321 stainless steel in H2SO4 solution was studied via the corrosive wear rate, the load bearing capacity of passive film and the relationship between pitting and corrosive wear. There is a critical load at natural potential, below which the corrosive wear rate is slightly lowered by Cl–, while above which is increased. At natural potential there are more pits at low load than that at a higher one in the wear tracks and the pits are also deeper. The load bearing capacity is lowered by Cl– at passive region and then the corrosive wear rate increased.

  12. Studies on corrosion protection of laser hybrid welded AISI 316 by laser remelting

    DEFF Research Database (Denmark)

    Olsen, Flemming Ove; Ambat, Rajan; Rasmussen, A.J.

    2005-01-01

    Unlike in autogenous laser welding, hybrid laser welding of stainless steel could introduce grain boundary carbides due to low cooling rates. Formation of grain boundary carbides leads to reduced corrosion properties. Studies have initially been carried out on hybrid laser welding and subsequent...... laser surface melting on microstructure and corrosion behaviour of AISI 316L welds. Welding and laser treatment parameters were varied. General corrosion behaviour of the weld and laser treated surface was characterised using a gel visualization test. The local electrochemistry of the weld and laser...... treated surface was investigated using a novel micro electrochemical technique with a tip resolution of ~1 mm. Results show that hybrid laser welding of 316L has increased corrosion susceptibility probably as a result of grain boundary carbide formation. However a suitable post laser treatment could...

  13. Characteristics and Modification of Non-metallic Inclusions in Titanium-Stabilized AISI 409 Ferritic Stainless Steel

    Science.gov (United States)

    Kruger, Dirk; Garbers-Craig, Andrie

    2017-02-01

    This study describes an investigation into the improvement of castability, final surface quality and formability of titanium-stabilized AISI 409 ferritic stainless steel on an industrial scale. Non-metallic inclusions found in this industrially produced stainless steel were first characterized using SEM-EDS analyses through the INCA-Steel software platform. Inclusions were found to consist of a MgO·Al2O3 spinel core, which acted as heterogeneous nucleation site for titanium solubility products. Plant-scale experiments were conducted to either prevent the formation of spinel, or to modify it by calcium treatment. Modification to spherical dual-phase spinel-liquid matrix inclusions was achieved with calcium addition, which eliminated submerged entry nozzle clogging for this grade. Complete modification to homogeneous liquid calcium aluminates was achieved at high levels of dissolved aluminum. A mechanism was suggested to explain the extent of modification achieved.

  14. Effect of Welding Processes on Tensile and Impact Properties, Hardness and Microstructure of AISI 409M Ferritic Stainless Joints Fabricated by Duplex Stainless Steel Filler Metal

    Institute of Scientific and Technical Information of China (English)

    A K Lakshminarayanan; K Shanmugam; V Balasubramanian

    2009-01-01

    The effect of welding processes such as shielded metal arc welding, gas metal arc welding and gas tungsten arc welding on tensile and impact properties of the ferritic stainless steel conforming to AISI 409M grade is studied. Rolled plates of 4 mm thickness were used as the base material for preparing single pass butt welded joints. Tensile and impact properties, microhardness, microstructure and fracture surface morphology of the welded joints have been evaluated and the results are compared. From this investigatio.n, it is found that gas tungsten arc welded joints of ferritic stainless steel have superior tensile and impact properties compared with shielded metal are and gas metal arc welded joints and this is mainly due to the presence of finer grains in fusion zone and heat affected zone.

  15. Weldability of dissimilar joint between F82H and SUS316L under fiber laser welding

    Energy Technology Data Exchange (ETDEWEB)

    Serizawa, Hisashi [Joining and Welding Research Institute, Osaka University, 11-1 Mihogaoka, Ibaraki, Osaka 567-0047 (Japan); Mori, Daiki; Shirai, Yuma; Ogiwara, Hiroyuki; Mori, Hiroaki [Graduate School of Engineering, Osaka University, 2-1 Yamadaoka, Suita, Osaka 565-0871 (Japan)

    2013-10-15

    Highlights: • The microstructure of F82H/SUS316L dissimilar joint can be divided into four regions. • In the case without beam position shift, hardness of WM cannot be reduced by PWHT. • The fiber laser welding would be applicable for constructing the dissimilar joint. -- Abstract: As one of the high beam quality heat sources, 4 kW fiber laser was applied for joining between reduced activation ferritic/martensitic steel, F82H and SUS316L austenitic stainless steel, and the microstructural analyses and Vickers hardness measurements were carried out before and after post-weld heat treatment (PWHT). The microstructure of joint can be divided into four regions which are base metal of F82H, heat affected zone (HAZ) in F82H, weld metal (WM) and base metal of SUS316L. Also, it is revealed that the high-power fiber laser can be employed for constructing butt joint between F82H and SUS316L by applying PWHT and shifting the laser beam position to SUS316L, where the distance between the contact face and beam should be set as a range from radius to diameter of laser beam.

  16. Study of corrosion resistance of AISI 444 ferritic stainless steel for application as a biomaterial; Estudo da resistencia a corrosao do aco inoxidavel ferritico AISI 444 para aplicacao como biomaterial

    Energy Technology Data Exchange (ETDEWEB)

    Marques, Rogerio Albuquerque

    2014-09-01

    Ferritic stainless steels are ferromagnetic materials. This property does not allow their use in orthopedic prosthesis. Nevertheless, in some specific applications, this characteristic is very useful, such as, for fixing dental and facial prostheses by using magnetic attachments. In this study, the corrosion resistance and cytotoxicity of the AISI 444 ferritic stainless steel, with low nickel content, extra-low interstitial levels (C and N) and Ti and Nb stabilizers, were investigated for magnetic dental attachments application. The ISO 5832-1 (ASTM F-139) austenitic stainless steel and a commercial universal keeper for dental attachment (Neo-magnet System) were evaluated for comparison reasons. The first stainless steel is the most used metallic material for prostheses, and the second one, is a ferromagnetic keeper for dental prostheses (NeoM). In vitro cytotoxicity analysis was performed by the red neutral incorporation method. The results showed that the AISI 444 stainless steel is non cytotoxic. The corrosion resistance was studied by anodic polarization methods and electrochemical impedance spectroscopy (EIS), in a saline phosphate buffered solution (PBS) at 37 °C. The electronic properties of the passive film formed on AISI 444 SS were evaluated by the Mott-Schottky approach. All tested materials showed passivity in the PBS medium and the passive oxide film presented a duplex nature. The highest susceptibility to pitting corrosion was associated to the NeoM SS. This steel was also associated to the highest dopant concentration. The comparatively low levels of chromium (nearly 12.5%) and molybdenum (0.3%) of NeoM relatively to the other studied stainless steels are the probable cause of its lower corrosion resistance. The NeoM chemical composition does not match that of the SUS444 standards. The AISI 444 SS pitting resistance was equivalent to the ISO 5832-1 pointing out that it is a potential candidate for replacement of commercial ferromagnetic alloys used

  17. The effect of glutaraldehyde on the development of marine biofilms formed on surfaces of AISI 304 stainless steel

    Energy Technology Data Exchange (ETDEWEB)

    Tapper, R.C.; Smith, J.R.; Beech, I.B. [Univ. of Portsmouth (United Kingdom). School of Chemistry, Physics, and Radiography; Viera, M.R.; Guiamet, P.S.; Videla, H. [Univ. of La Plata (Argentina); Swords, C.L.; Edyvean, R.G.J. [Univ. of Sheffield (United Kingdom). Dept. of Mechanical and Process Engineering

    1997-08-01

    The effect of pre-conditioning polished and unpolished AISI 304 stainless steel surfaces with glutaraldehyde on the attachment, growth and morphology of an aerobic consortium of marine bacteria was investigated using total cell number counts, epifluorescence microscopy, Atomic Force Microscopy (AFM), Environmental Scanning Electron Microscopy (ESEM) and grazing-angle Fourier Transform Infrared (FTIR) spectroscopy. Both fully hydrated and dehydrated biofilms were studied using AFM and ESEM. Formation of the conditioning layer on steel surfaces from the culture medium, in the presence and absence of glutaraldehyde was monitored in-situ employing AFM and Grazing Angle FTIR spectroscopy. The influence of both surface area and surface energy upon the numbers of bacteria attached to polished and unpolished coupons was determined. This study has shown the influence of pretreatment of AISI 304 stainless steel with glutaraldehyde upon biofilm formation and has demonstrated the ability of AFM, ESEM and FTIR to be used as valuable tools for the in-situ investigation of the effect of biocides on bacterial biofilms.

  18. Multiaxial elastoplastic cyclic loading of austenitic 316L steel

    Directory of Open Access Journals (Sweden)

    V. Mazánová

    2017-04-01

    Full Text Available Cyclic stress-strain response and fatigue damage character has been investigated in austenitic stainless steel 316L. Hollow cylindrical specimens have been cyclically deformed in combined tension-compression and torsion under constant strain rate condition and different constant strain and shear strain amplitudes. In-phase and 90° out-of-phase cyclic straining was applied and the stress response has been monitored. Cyclic hardening/softening curves were assessed in both channels. Cyclic softening followed for higher strain amplitudes by long-term cyclic hardening was observed. Cyclic stress-strain curves were determined. Study of the surface damage in fractured specimens revealed the types and directions of principal cracks and the sources of fatigue crack initiation in slip bands.

  19. Microstructure, mechanical properties and chemical degradation of brazed AISI 316 stainless steel/alumina systems

    Energy Technology Data Exchange (ETDEWEB)

    Paiva, O.C. [Instituto Superior de Engenharia do Porto (ISEP), Rua Dr. Antonio Bernardino de Almeida 431, 4200-072 Porto (Portugal)], E-mail: omp@isep.ipp.pt; Barbosa, M.A. [Instituto de Engenharia Biomedica (INEB), Rua do Campo Alegre, 823, 4150-180 Porto (Portugal); Faculdade de Engenharia da Universidade do Porto (FEUP), Rua Roberto Frias s/n, 4200-465 Porto (Portugal)

    2008-05-15

    The main aims of the present study are simultaneously to relate the brazing parameters with: (i) the correspondent interfacial microstructure, (ii) the resultant mechanical properties and (iii) the electrochemical degradation behaviour of AISI 316 stainless steel/alumina brazed joints. Filler metals on such as Ag-26.5Cu-3Ti and Ag-34.5Cu-1.5Ti were used to produce the joints. Three different brazing temperatures (850, 900 and 950 deg. C), keeping a constant holding time of 20 min, were tested. The objective was to understand the influence of the brazing temperature on the final microstructure and properties of the joints. The mechanical properties of the metal/ceramic (M/C) joints were assessed from bond strength tests carried out using a shear solicitation loading scheme. The fracture surfaces were studied both morphologically and structurally using scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS) and X-ray diffraction analysis (XRD). The degradation behaviour of the M/C joints was assessed by means of electrochemical techniques. It was found that using a Ag-26.5Cu-3Ti brazing alloy and a brazing temperature of 850 deg. C, produces the best results in terms of bond strength, 234 {+-} 18 MPa. The mechanical properties obtained could be explained on the basis of the different compounds identified on the fracture surfaces by XRD. On the other hand, the use of the Ag-34.5Cu-1.5Ti brazing alloy and a brazing temperature of 850 deg. C produces the best results in terms of corrosion rates (lower corrosion current density), 0.76 {+-} 0.21 {mu}A cm{sup -2}. Nevertheless, the joints produced at 850 deg. C using a Ag-26.5Cu-3Ti brazing alloy present the best compromise between mechanical properties and degradation behaviour, 234 {+-} 18 MPa and 1.26 {+-} 0.58 {mu}A cm{sup -2}, respectively. The role of Ti diffusion is fundamental in terms of the final value achieved for the M/C bond strength. On the contrary, the Ag and Cu distribution along the

  20. Parameter Optimization Of Natural Hydroxyapatite/SS316l Via Metal Injection Molding (MIM)

    Science.gov (United States)

    Mustafa, N.; Ibrahim1, M. H. I.; Amin, A. M.; Asmawi, R.

    2017-01-01

    Metal injection molding (MIM) are well known as a worldwide application of powder injection molding (PIM) where as applied the shaping concept and the beneficial of plastic injection molding but develops the applications to various high performance metals and alloys, plus metal matrix composites and ceramics. This study investigates the strength of green part by using stainless steel 316L/ Natural hydroxyapatite composite as a feedstock. Stainless steel 316L (SS316L) was mixed with Natural hydroxyapatite (NHAP) by adding 40 wt. % Low Density Polyethylene and 60 %wt. Palm Stearin as a binder system at 63 wt. % powder loading consist of 90 % wt. of SS316 L and 10 wt. % NHAP prepared thru critical powder volume percentage (CPVC). Taguchi method was functional as a tool in determining the optimum green strength for Metal Injection Molding (MIM) parameters. The green strength was optimized with 4 significant injection parameter such as Injection temperature (A), Mold temperature (B), Pressure (C) and Speed (D) were selected throughout screening process. An orthogonal array of L9 (3)4 was conducted. The optimum injection parameters for highest green strength were established at A1, B2, C0 and D1 and where as calculated based on Signal to Noise Ratio.

  1. Effect of surface mechanical attrition on surface and properties of low temperature aluminized layer of 316L stainless steel%机械研磨对316L不锈钢表面及其低温渗铝层性能的影响

    Institute of Scientific and Technical Information of China (English)

    宋月鹏; 刘自平; 陈义祥; 李江涛; 高东升; 陈苗苗; 杨增朝; 贺刚

    2016-01-01

    利用扫描电镜(SEM),表面粗糙度测试仪,电化学工作站等仪器,分析了机械研磨对316L不锈钢件表面及其低温渗铝层性能的影响.结果表明:机械研磨过程中,材料表面在研磨球撞击、旋压等多种作用下产生大塑性变形,形成大量组织结构缺陷并细化表层晶粒,导致试样表面粗糙度变大,硬度提高,直接影响到热处理过程及其渗层性能;机械研磨处理的316L不锈钢试样经低温渗铝后,与对比试样相比,渗铝层硬度可提高2倍以上,抗高温氧化性及耐腐蚀性能均有显著提高,同时进行了相关机理的分析探讨.%Effect of surface mechanical attrition(SMA) on properties of aluminized layer of a 316L stainless steel was analyzed by means of scanning electron microscopy (SEM),surface roughness test and corrosion resistance test on an electrochemical workstation.The results indicate that the surface roughness and hardness increase due to the SMA treating.In the SMA process,with the impacting and spinning action of the grinding balls on the material surface,severe plastic deformation,a large number of defects like dislocation,subgrain boundary and grain refining occur.After SMA and aluminizing at low temperature,the properties of the aluminized layer of the 316L stainless steel are improved:hardness of the layer is three times than that of the substrate,high temperature oxidation and corrosion resistance increase significantly.Furthermore,the influence mechanism of the SMA on the properties of the aluminized layer is also explored.

  2. 植酸在316L不锈钢表面的自组装及缓蚀性能研究%Research on Self-assembly Behavior and Corrosion Inhibition Performance of Phytic Acid on 316L Stainless Steel Surface

    Institute of Scientific and Technical Information of China (English)

    王海人; 周洋; 屈钧娥; 王海鹏; 曹志勇

    2013-01-01

    以浸泡法在化学氧化处理前后的316L不锈钢表面制备了植酸自组装膜,通过动电位扫描、SEM观察及FT-IR测试,研究了组装液pH与组装时间对植酸自组装膜吸附行为及耐蚀性能的影响.结果表明:植酸被成功地组装到316L不锈钢表面,并使其耐腐蚀性能大大提高.相比而言,化学氧化处理有利于形成更致密、更耐腐蚀的自组装膜.不经化学氧化处理时,植酸组装的最佳pH为6.90,最佳时间为12 h;而经化学氧化处理时,植酸组装的最佳pH也为6.90,但最佳时间缩短为4h.%The phytic acid self-assembled film (SAM) was prepared on 316L stainless steel surface before and after chemical oxidation by immersion method.The effect of SAM solution pH and SAM time on the adsorption behavior and corrosion inhibition performance of the phytic acid SAM was investigated by potential dynamic scan,SEM (scanning electron microscope) observation and FT-IR (Fourier transformed infrared spectroscopy) testing.The experimental results show that phytic acid has been successfully assembled to the surface of 316L stainless steel,which greatly improves the corrosion resistance of the metal.The chemical oxidation pretreatment is beneficial for the formation of a denser SAM with more notable corrosion resistant performance.For the samples without chemical oxidation treatment,the optimum pH for the assembly of phytic acid is 6.90 and the best assembly time is 12 h.And for those with chemical oxidation,the optimum pH is still 6.90 while the best assembly time reduces to 4 h.

  3. Effects of laser power density on static and dynamic mechanical properties of dissimilar stainless steel welded joints

    Institute of Scientific and Technical Information of China (English)

    Yan-Peng Wei; Mao-Hui Li; Gang Yu; Xian-Qian Wu; Chen-Guang Huang; Zhu-Ping Duan

    2012-01-01

    The mechanical properties of laser welded joints under impact loadings such as explosion and car crash etc.are critical for the engineering designs. The hardness,static and dynamic mechanical properties of AISI304 and AISI316L dissimilar stainless steel welded joints by CO2 laser were experimentally studied. The dynamic strain-stress curves at the strain rate around 103 s-1 were obtained by the split Hopkinson tensile bar (SHTB).The static mechanical properties of the welded joints have little changes with the laser power density and all fracture occurs at 316 L side.However,the strain rate sensitivity has a strong dependence on laser power density.The value of strain rate factor decreases with the increase of laser power density.The welded joint which may be applied for the impact loading can be obtained by reducing the laser power density in the case of welding quality assurance.

  4. Performance evaluation of vegetable-based oils in drilling austenitic stainless steel

    DEFF Research Database (Denmark)

    Belluco, Walter; De Chiffre, Leonardo

    2004-01-01

    The efficiency of six cutting oils was evaluated in drilling AISI 316L austenitic stainless steel using conventional HSS-Co tools by measurements of tool life, tool wear, cutting forces and chip formation. Seven tools were tested with each fluid to catastrophic failure. Cutting forces and chip...... in a measurement capability comparable to that obtained using tool life as a performance criterion. As a consequence, it is suggested that drilling thrust can be used to assess the performance of cutting fluids in drilling stainless steel, resulting in considerable time savings and cost reduction with respect...

  5. Hydrogen Silsesquioxane based silica glass coatings for the corrosion protection of austenitic stainless steel

    DEFF Research Database (Denmark)

    Lampert, Felix; Jensen, Annemette Hindhede; Din, Rameez Ud

    2016-01-01

    The application of stainless steels in hostile environments, such as concentrated acid or hot sea water, requires additional surface treatments, considering that the native surface oxide does not guarantee sufficient corrosion protection under these conditions. In the present work, silica-like thin......-film barrier coatings were deposited on AISI 316L grade austenitic stainless steel with 2B surface finish from Hydrogen Silsesquioxane (HSQ) spin-on-glass precursor and thermally cured to tailor the film properties. Results showed that curing at 500 °C resulted in a film-structure with a polymerized siloxane...

  6. Wear properties of Fe-Cr-C and B{sub 4}C powder coating on AISI 316 stainless steel analyzed by the Taguchi method

    Energy Technology Data Exchange (ETDEWEB)

    Gur, Ali Kaya; Ozay, Cetin; Orhan, Ayhan; Buytoz, Soner; Caligulu, Ugur; Yigitturk, Necmettin [Firat Univ., Elazig (Turkey). Faculty of Technical Education

    2014-06-01

    In this study, the plasma arc welded cladding of FeCrC and B{sub 4}C powder mixtures alloyed with 70 wt.-% Cr on the surface of AISI 316 stainless steel was investigated. Application of the Taguchi method revealed respective effects on the abrasive wear resistance of the cladding layer on the stainless steel. The abrasive wear behaviour of the AISI 316 stainless steel surfaces coated with Fe-Cr-C and with 10 wt.-%, 15 wt.-%, 20 wt.-%, and 25 wt.-% B{sub 4}C was investigated by using four loads and four distances for the 220 mesh SiC abrasive. Results were analyzed by variance analysis using ANOVA, and effects of parameters on the wear rate were determined as percentage rate. Furthermore, the error ratio was statistically evaluated. The experimental results were analyzed by the respective analysis of means and variance which is discussed in detail. (orig.)

  7. Correlation between surface physicochemical properties and the release of iron from stainless steel AISI 304 in biological media.

    Science.gov (United States)

    Hedberg, Yolanda; Karlsson, Maria-Elisa; Blomberg, Eva; Odnevall Wallinder, Inger; Hedberg, Jonas

    2014-10-01

    Stainless steel is widely used in biological environments, for example as implant material or in food applications, where adsorption-controlled ligand-induced metal release is of importance from a corrosion, health, and food safety perspective. The objective of this study was to elucidate potential correlations between surface energy and wettability of stainless steel surfaces and the release of iron in complexing biological media. This was accomplished by studying changes in surface energies calculated from contact angle measurements, surface oxide composition (X-ray photoelectron spectroscopy), and released iron (graphite furnace atomic absorption spectroscopy) for stainless steel grade AISI 304 immersed in fluids containing bovine serum albumin or citric acid, and non-complexing fluids such as NaCl, NaOH, and HNO3. It was shown that the surface wettability and polar surface energy components were all influenced by adventitious atmospheric carbon (surface contamination of low molecular weight), rather than differences in surface oxide composition in non-complexing solutions. Adsorption of both BSA and citrate, which resulted in ligand-induced metal release, strongly influenced the wettability and the surface energy, and correlated well with the measured released amount of iron.

  8. Study on behavior of plasma nitrided 316L in PEMFC working conditions

    Energy Technology Data Exchange (ETDEWEB)

    Tian, Rujin [Institute of Materials and Technology, Dalian Maritime University, Linghailu No.1, Ganjingzi District, Dalian, Lianoing 116026 (China); College of Materials and Engineering, Dalian Jiaotong University, Dalian 116028 (China); Sun, Juncai [Institute of Materials and Technology, Dalian Maritime University, Linghailu No.1, Ganjingzi District, Dalian, Lianoing 116026 (China); Wang, Jianli [Department of Basic Science, Changchun University of Technology, Changchun 130012 (China)

    2008-12-15

    Stainless steel bipolar plates for the polymer electrolyte membrane fuel cell (PEMFC) offer many advantages over conventional machined graphite and graphite-composites. However, the interfacial ohmic loss between the metallic bipolar plate and membrane electrode assembly due to corrosion decreases the overall power output of PEMFC. A lower temperature (at 370 C) plasma nitriding was applied to modify the surface of stainless steel 316L bipolar plates. The results of electrochemical measurements show that corrosion resistance of the plasma nitrided 316L is improved in simulated PEMFC anode/cathode environments purged with H{sub 2}/air at 70 C. The surface conductivity of the nitrided layer is better than that of the air-formed oxide film. The interfacial contact resistance (ICR) between the passive film and carbon paper increases very little after potentiostatic polarization for 4 h, which indicates potential for good stability of this material in highly corrosive fuel cell environments. (author)

  9. Study of the tensile behavior of AISI type 316 stainless steel using acoustic emission and infrared thermography techniques

    Directory of Open Access Journals (Sweden)

    Thodamrakandy Haneef

    2015-07-01

    Full Text Available Acoustic emission (AE and infrared thermography technique (IRT have been used to study the tensile behavior of AISI type 316 stainless steel. Strain rates of tensile testing were varied from 1.4 × 10−3 s−1 to 1.4 × 10−2 s−1. AE root mean square voltage increases with increase in strain rate due to the increase in source activation. Dominant frequency of the AE signals generated during different regions of tensile deformation has also been used to compare the results for different strain rates. The dominant frequency increases from elastic region to around 590 kHz during work hardening and 710 kHz around ultimate tensile strength (UTS for all the strain rates. Temperature changes during different regions of deformation are monitored using infrared thermography. The temperature rise in the work hardening region is found to approximately increase linearly with time and from the slopes of the linear regression analyses the rate of temperature rise in the work-hardening region is obtained which is found to be very sensitive to strain rates. From the experimental results an empirical equation that relates the rate of temperature increase with strain rate and thermal hardening coefficient is obtained. The correlation between the variation of AE dominant frequency and temperature rise during different deformation regions provided better insight into the tensile behavior of AISI type 316 SS for different strain rates.

  10. Phase transformations in an AISI 410S stainless steel observed in directional and laser-induced cooling regimes

    Directory of Open Access Journals (Sweden)

    Milton Sergio Fernandes de Lima

    2012-02-01

    Full Text Available The applications of the chromium ferritic stainless steel AISI 410S have been considerably increased in the last years in many technical fields as chemical industries and oil or gas transportation. However, the phase transformation temperatures are, currently, unknown for this alloy. The aim of this work is to determine the alpha to gamma transformation temperatures of the AISI 410S alloy in different cooling conditions and to analyze them using continuous cooling theory. In order to achieve different cooling rates and thermal conditions, two complementary techniques were used: Bridgman furnace crystal growth and laser remelting technique. The measured solidification temperature was around 1730 and 1750 K. Plate-like and dendritic austenite precipitates were obtained in solid-state phase using growth rates between 5 and 10 µm/s in directional growth experiments. Only plate-like austenite phase was observed in the experiments using growth rates above 100 µm/s. The appearance of dendrites, with the consequent segregation of the elements, can be previously determined by the microstructure modeling currently proposed. Massive austenite can be produced from 0.3 to 10 mm/s rates at temperatures between 1100-1300 K. The structure might be less sensitive to corrosion because this phase is produced without microsegregation.

  11. Optimisation of GTAW parameters for the tensile strength of AISI 304 stainless steel welds using the Taguchi method

    Energy Technology Data Exchange (ETDEWEB)

    Ertan, Rukiye

    2012-07-01

    The influence of welding parameters, i. e. the welding current, root gap and the shielding gas flow rate, on the tensile strength of AISI 304 austenitic stainless steel welded with gas tungsten arc welding was investigated. To determine the optimum levels of the parameters, the Taguchi approach was used to increase the tensile strength. The results were analysed by investigating the variance by which welding parameters significantly affect the response. Mathematical models were developed to describe the influence of the selected parameters on the tensile strength. The results were confirmed by experiments. [German] Der Einfluss der Schweissparameter, d. h. der Schweissstromstaerke, des Wurzelspaltes und des Schutzgasdurchflusses, auf die Zugfestigkeit des WIG-geschweissten hochlegierten Stahles AISI 304 ist in der diesem Beitrag zugrunde liegenden Studie untersucht worden. Um die optimale Groesse der Parameter in Bezug auf eine Erhoehung der Zugfestigkeit zu bestimmen, wurde der Ansatz nach Taguchi gewaehlt. Die Ergebnisse wurden analysiert, indem die Varianz ermittelt wurde, mit der die Schweissparameter signifikant die Ergebnisse veraendern. Es wurden mathematische Modelle entwickelt, um den Einfluss der gewaehlten Parameter auf die Zugfestigkeit zu beschreiben. Die Ergebnisse wurden durch Experimente bestaetigt.

  12. Corrosion behavior of powder metallurgical stainless steels in urban and marine environments

    Directory of Open Access Journals (Sweden)

    Bautista, A.

    2006-06-01

    Full Text Available This work studies the development of corrosive attack on sintered components manufactured from AISI 316L and AISI 304L powders. The stainless steels were sintered in vacuum and in nitrogen-base atmosphere at 1,120 and 1,250 ºC, and their corrosion resistance was then analyzed by electrochemical techniques and by atmospheric corrosion testing (two years at urban and marine test sites. Images are shown of the morphology of the attack on the surface of the stainless steels and the development of this attack in the interior of the material.

    Este trabajo estudia el desarrollo del proceso corrosivo en componentes sinterizados fabricados a partir de polvos de AISI 316L y AISI 304L. Los aceros inoxidables fueron sinterizados en vacío y en atmósfera base nitrógeno a 1.120 y 1.250 ºC y, su resistencia a corrosión se ha analizado mediante técnicas electroquímicas y mediante ensayos de corrosión atmosférica (dos años en ambientes urbano y marino. Se muestran imágenes de la morfología del ataque en la superficie de los aceros inoxidables y del desarrollo de este ataque en el interior del material.

  13. Comparison of Roller Burnishing Method with Other Hole Surface Finishing Processes Applied on AISI 304 Austenitic Stainless Steel

    Science.gov (United States)

    Akkurt, Adnan

    2011-08-01

    Component surface quality and selection of the optimum material are the main factors determining the performance of components used in machine manufacturing. The level of hole surface quality can be evaluated by the measurements regarding surface roughness, micro-hardness, and cylindricity. In this study, data had been obtained for different hole drilling methods. The characteristics of materials obtained after applications were compared for different hole-finishing processes to identify best hole drilling method. AISI 304 austenitic stainless steel material was used. Surface finishing of holes were performed using drilling, turning, reaming, grinding, honing, and roller burnishing methods. The results of the study show that the roller burnishing method gives the best results for mechanical, metallurgical properties, and hole surface quality of the material. On the other hand, the worst characteristics were obtained in the drilling method.

  14. Experimental Determination of Temperature During Rotary Friction Welding of AA1050 Aluminum with AISI 304 Stainless Steel

    Directory of Open Access Journals (Sweden)

    Eder Paduan Alves

    2012-03-01

    Full Text Available The purpose of this study was the temperature monitoring at bonding interface during the rotary friction welding process of dissimilar materials: AA1050 aluminum with AISI 304 stainless steel. As it is directly related to the mechanical strenght of the junction, its experimental determination in real time is of fundamental importance for understanding and characterizing the main process steps, and the definition and optimization of parameters. The temperature gradients were obtained using a system called Thermocouple Data-Logger, which allowed monitoring and recording data in real-time operation. In the graph temperature versus time obtained, the heating rates, cooling were analyzed, and the maximum temperature was determined that occurred during welding, and characterized every phases of the process. The efficiency of this system demonstrated by experimental tests and the knowledge of the temperature at the bonding interface open new lines of research to understand the process of friction welding.

  15. Effect of copper on the formation of strain-induced martensite in two austenitic stainless steels AISI 304

    Energy Technology Data Exchange (ETDEWEB)

    Gilapa, Leonidas Cayo Mamani, E-mail: leonidas@ifsc.edu.br [Instituto Federal de Santa Catarina, Rua Pavão, 1337, Bairro Costa e Silva, Joinville, SC CEP 89220-200 (Brazil); Oliveira, Carlos Augusto Silva de, E-mail: carlos.a@ufsc.br [Universidade Federal de Santa Catarina, Campus Universitário Reitor João David Ferreira Lima, Trindade, Florianópolis, SC CEP 88040-970 (Brazil); Silva, Manoel Ribeiro da, E-mail: mrsilva@unifei.edu.br [Universidade Federal de Itajubá, Instituto de Ciências, Itajubá (Brazil)

    2015-01-12

    The transformation of strain-induced martensite in two metastable austenitic stainless steels, AISI 304, with the same basic composition and concentrations of Cu variables was characterized by transmission electron microscopy and magnetic measurements. The deformations to induce the formation of martensite were performed using the test of conformability with Nakajima tooling at room temperature. The results obtained for the various samples showed that the steel with lower content of Cu presented higher degree of magnetization. Also it was observed that the martensite magnetic α′ and paramagnetic ε are formed at the intersection of dislocation, in the grain boundary, inside and at the edge of twinned and the stacking faults in the austenite.

  16. Application of Deep Cryogenic Treatment to Uncoated Tungsten Carbide Inserts in the Turning of AISI 304 Stainless Steel

    Science.gov (United States)

    Özbek, Nursel Altan; Çİçek, Adem; Gülesİn, Mahmut; Özbek, Onur

    2016-12-01

    This study investigated the effects of deep cryogenic treatment (DCT) on the wear performance of uncoated tungsten carbide inserts. AISI 304 austenitic stainless steel, widely used in industry, was selected as the workpiece material. Cutting experiments showed that the amount of wear significantly increased with increasing cutting speed. In addition, it was found that DCT contributed to the wear resistance of the turning inserts. The treated turning inserts were less worn by 48 and 38 pct in terms of crater wear and notch wear, respectively, whereas they exhibited up to 18 pct superior wear performance in terms of flank wear. This was attributed to the precipitation of new and finer η-carbides and their homogeneous distribution in the microstructure of the tungsten carbide material after deep cryogenic treatment. Analyses via image processing, hardness measurements, and SEM observations confirmed these findings.

  17. Application of Deep Cryogenic Treatment to Uncoated Tungsten Carbide Inserts in the Turning of AISI 304 Stainless Steel

    Science.gov (United States)

    Özbek, Nursel Altan; Çİçek, Adem; Gülesİn, Mahmut; Özbek, Onur

    2016-09-01

    This study investigated the effects of deep cryogenic treatment (DCT) on the wear performance of uncoated tungsten carbide inserts. AISI 304 austenitic stainless steel, widely used in industry, was selected as the workpiece material. Cutting experiments showed that the amount of wear significantly increased with increasing cutting speed. In addition, it was found that DCT contributed to the wear resistance of the turning inserts. The treated turning inserts were less worn by 48 and 38 pct in terms of crater wear and notch wear, respectively, whereas they exhibited up to 18 pct superior wear performance in terms of flank wear. This was attributed to the precipitation of new and finer η-carbides and their homogeneous distribution in the microstructure of the tungsten carbide material after deep cryogenic treatment. Analyses via image processing, hardness measurements, and SEM observations confirmed these findings.

  18. Tribological behavior of AISI302 austenitic stainless steel modified by elevated temperature nitrogen plasma immersion ion implantation

    Institute of Scientific and Technical Information of China (English)

    JIANG Shao-qun; MA Xin-xin; SUN Yue

    2004-01-01

    AISI302 stainless steel samples were modified by elevated temperature nitrogen plasma immersion ion implantation at temperature ranging from 330 ℃ to 450 ℃. The tribological behaviors of the implanted layers of the samples were investigated. The samples were characterized by Auger electron spectroscopy (AES), glancing angle X-ray diffraction (GXRD), and nanoindentation. The results show that the implantation temperature plays an important rule on the microstructure and surface properties of the implanted layers. The thickness of the modified layer implanted at 390 ℃ is about 9 μm. It is improved about two orders compared with that of the implanted at room temperature. The surface nanohardness and the wear resistance of elevated temperature implanted layers increase significantly, and the friction coefficient decreases obviously in comparison with the unimplanted one. These data suggests that the improvement results from the formation of new phases such as ε-(Fe, Cr, Ni)2+xN, or noncrystal phase.

  19. High Speed Milling Parameter Optimization for 316L Stainless Steel Based on Taguchi Method and PCA%基于田口法和主成分分析法的高速铣削316L不锈钢的参数优化

    Institute of Scientific and Technical Information of China (English)

    阙燚彬

    2016-01-01

    In order to fully consider the comprehensive effects of cutting parameters on cutting force and vibration in the cutting process, combining with Taguchi method and PCA, using SPASS software, taking the cutting force and the cutting vibration as com⁃prehensive targets, the optimization of the cutting parameters was done. The best cutting parameters for small diameter cutter high speed milling of 316L stainless steel profile were gotten and the correctness of the result was verified.%为了全面考虑切削参数对切削过程中切削力和振动的综合影响,将田口法与主成分分析法相结合,应用SPASS软件,以切削合力和切削振动为综合目标进行切削参数优化,得出小直径铣刀高速铣削316L不锈钢外形轮廓的最优的切削参数组合,并验证了结果的正确性。

  20. Surface-protein interactions on different stainless steel grades: effects of protein adsorption, surface changes and metal release.

    Science.gov (United States)

    Hedberg, Y; Wang, X; Hedberg, J; Lundin, M; Blomberg, E; Wallinder, I Odnevall

    2013-04-01

    Implantation using stainless steels (SS) is an example where an understanding of protein-induced metal release from SS is important when assessing potential toxicological risks. Here, the protein-induced metal release was investigated for austenitic (AISI 304, 310, and 316L), ferritic (AISI 430), and duplex (AISI 2205) grades in a phosphate buffered saline (PBS, pH 7.4) solution containing either bovine serum albumin (BSA) or lysozyme (LSZ). The results show that both BSA and LSZ induce a significant enrichment of chromium in the surface oxide of all stainless steel grades. Both proteins induced an enhanced extent of released iron, chromium, nickel and manganese, very significant in the case of BSA (up to 40-fold increase), whereas both proteins reduced the corrosion resistance of SS, with the reverse situation for iron metal (reduced corrosion rates and reduced metal release in the presence of proteins). A full monolayer coverage is necessary to induce the effects observed.

  1. Nickel release from nickel-plated metals and stainless steels.

    Science.gov (United States)

    Haudrechy, P; Foussereau, J; Mantout, B; Baroux, B

    1994-10-01

    Nickel release from nickel-plated metals often induces allergic contact dermatitis, but, for nickel-containing stainless steels, the effect is not well-known. In this paper, AISI 304, 316L, 303 and 430 type stainless steels, nickel and nickel-plated materials were investigated. 4 tests were performed: patch tests, leaching experiments, dimethylglyoxime (DMG) spot tests and electrochemical tests. Patch tests showed that 96% of the patients were intolerant to Ni-plated samples, and 14% to a high-sulfur stainless steel (303), while nickel-containing stainless steels with a low sulfur content elicited no reactions. Leaching experiments confirmed the patch tests: in acidic artificial sweat, Ni-plated samples released about 100 micrograms/cm2/week of nickel, while low-sulfur stainless steels released less than 0.03 microgram/cm2/week of nickel, and AISI 303 about 1.5 micrograms/cm2/week. Attention is drawn to the irrelevance of the DMG spot test, which reveals Ni present in the metal bulk but not its dissolution rate. Electrochemical experiments showed that 304 and 316 grades remain passive in the environments tested, while Ni-plated steels and AISI 303 can suffer significant cation dissolution. Thus, Ni-containing 304 and 316 steels should not induce contact dermatitis, while 303 should be avoided. A reliable nitric acid spot test is proposed to distinguish this grade from other stainless steels.

  2. Development of nanostructured SUS316L-2%TiC with superior tensile properties

    Science.gov (United States)

    Sakamoto, T.; Kurishita, H.; Matsuo, S.; Arakawa, H.; Takahashi, S.; Tsuchida, M.; Kobayashi, S.; Nakai, K.; Terasawa, M.; Yamasaki, T.; Kawai, M.

    2015-11-01

    Structural materials used in radiation environments require radiation tolerance and sufficient mechanical properties in the controlled state. In order to offer SUS316L austenitic stainless steel with the assumed requirements, nanostructured SUS316L with TiC addition of 2% (SUS316L-2TiC) that is capable of exhibiting enhanced tensile ductility and flow strength sufficient for structural applications was fabricated by advanced powder metallurgical methods. The methods include MA (Mechanical Alloying), HIP (Hot Isostatic Pressing), GSMM (Grain boundary Sliding Microstructural Modification) for ductility enhancement, cold rolling at temperatures below Md (the temperature where the martensite phase occurs by plastic deformation) for phase transformation from austenite to martensite and heat treatment for reverse transformation from martensite to austenite. It is shown that the developed SUS316L-2TiC exhibits ultrafine grains with sizes of 90-270 nm, accompanied by TiC precipitates with 20-50 nm in grain interior and 70-110 nm at grain boundaries, yield strengths of 1850 to 900 MPa, tensile strengths of 1920 to 1100 MPa and uniform elongations of 0.6-21%, respectively, depending on the heat treatment temperature after rolling at -196 °C.

  3. Martensitic Transformation in Ultrafine-Grained Stainless Steel AISI 304L Under Monotonic and Cyclic Loading

    Directory of Open Access Journals (Sweden)

    Heinz Werner Höppel

    2012-02-01

    Full Text Available The monotonic and cyclic deformation behavior of ultrafine-grained metastable austenitic steel AISI 304L, produced by severe plastic deformation, was investigated. Under monotonic loading, the martensitic phase transformation in the ultrafine-grained state is strongly favored. Under cyclic loading, the martensitic transformation behavior is similar to the coarse-grained condition, but the cyclic stress response is three times larger for the ultrafine-grained condition.

  4. Contribution to the Study of Effects of Surface State of Welded Joints in Stainless Steel Upon Resistance Towards Pitting Corrosion

    Directory of Open Access Journals (Sweden)

    Juraga, I.

    2007-01-01

    Full Text Available Successful corrosion resistance of stainless steels is based on their natural ability of passivation, i.e. formation of film of chromium oxides that prevents corrosion in many environments. Any nonuniformity of surface layers may be initial spot for corrosion processes and damages. In this contribution, beside real corrosion damages occurred in practice, results of testing of pitting corrosion resistance of weld beads made applying TIG process on AISI 316L steel grade are presented. SEM and EDX testing, as well as electrochemical corrosion testing confirmed adverse effects of heat tints zones upon corrosion resistance of stainless steels.

  5. Algunas observaciones sobre la sinterización del acero austenítico 316L en atmósfera de argón

    Directory of Open Access Journals (Sweden)

    Gómez, F.

    1998-05-01

    Full Text Available PM high speed steels are prone to higher corrosion rates due to residual porosity as well as chromium depletion of the matrix during sintering AISI 316L powders have been cold compacted (100-1,000 MPa and sintered (1,000-1,250°C, 15-240 min under several argon containing or vacuum atmospheres. Better densification rates can be achieved as sintering time or temperature increase in the presence of argon. No surface oxidation has been observed with the use of low pressure argon atmospheres, as long as samples are protected in a stainless steel partially sealed container.

    La utilización de acero inoxidable pulvimetalúrgico está limitada, entre otras razones, por la presencia de porosidad que pueda favorecer procesos corrosivos, así como a posibles pérdidas de cromo en la matriz durante los procesos de sinterización. Se han realizado experiencias de procesado de polvos de acero 316L con distintas presiones de compactación (100-1.000 MPa, temperaturas de sinterización (1.100-1.250°C, tiempos de sinterización (15-240 min y en distintas atmósferas de sinterización, de argón y vacío. Se obtiene una mejor densificación con elevada temperatura y tiempos de sinterización en atmósferas de argón a baja presión. En dicha atmósfera, no se produce oxidación superficial aislando parcialmente las muestras del flujo directo del argón.

  6. Exploration of surface hydrophilic properties on AISI 304 stainless steel and silicon wafer against aging after atmospheric pressure plasma treatment

    Science.gov (United States)

    Chuang, Shang-I.; Duh, Jenq-Gong

    2014-11-01

    The aim of this work is to seek the enhanced surface hydrophilic properties on AISI 304 stainless steel and silicon wafer after atmospheric pressure plasma treatment using a specifically designed atmospheric pressure plasma jet. The aging tendency of surface hydrophilic property under air is highlighted. It is concluded that both of the silicon wafer and stainless steel treated with plasma generated from supply gas of argon 15 slm mixed with oxygen 40 sccm shows a better tendency on remaining high water contact angle as compared to that with pure argon and nitrogen addition. Additional peaks of O I (777, 844 nm), O II (408 nm) are detected by optical emission spectroscope indicating the presence of the oxygen radicals and ionic species, which interact with surfaces and thus contribute to low water contact angle (WCA) surfaces. Moreover, the result acquired from X-ray photoelectron spectroscopy (XPS) indicates that the increase in the oxygen-related bonding exhibits a better contribution on remaining high surface energy over a period of time.

  7. Parametric Optimization Of Gas Metal Arc Welding Process By Using Grey Based Taguchi Method On Aisi 409 Ferritic Stainless Steel

    Science.gov (United States)

    Ghosh, Nabendu; Kumar, Pradip; Nandi, Goutam

    2016-10-01

    Welding input process parameters play a very significant role in determining the quality of the welded joint. Only by properly controlling every element of the process can product quality be controlled. For better quality of MIG welding of Ferritic stainless steel AISI 409, precise control of process parameters, parametric optimization of the process parameters, prediction and control of the desired responses (quality indices) etc., continued and elaborate experiments, analysis and modeling are needed. A data of knowledge - base may thus be generated which may be utilized by the practicing engineers and technicians to produce good quality weld more precisely, reliably and predictively. In the present work, X-ray radiographic test has been conducted in order to detect surface and sub-surface defects of weld specimens made of Ferritic stainless steel. The quality of the weld has been evaluated in terms of yield strength, ultimate tensile strength and percentage of elongation of the welded specimens. The observed data have been interpreted, discussed and analyzed by considering ultimate tensile strength ,yield strength and percentage elongation combined with use of Grey-Taguchi methodology.

  8. Effect of electromagnetic interaction during fusion welding of AISI 2205 duplex stainless steel on the corrosion resistance

    Science.gov (United States)

    García-Rentería, M. A.; López-Morelos, V. H.; González-Sánchez, J.; García-Hernández, R.; Dzib-Pérez, L.; Curiel-López, F. F.

    2017-02-01

    The effect of electromagnetic interaction of low intensity (EMILI) applied during fusion welding of AISI 2205 duplex stainless steel on the resistance to localised corrosion in natural seawater was investigated. The heat affected zone (HAZ) of samples welded under EMILI showed a higher temperature for pitting initiation and lower dissolution under anodic polarisation in chloride containing solutions than samples welded without EMILI. The EMILI assisted welding process developed in the present work enhanced the resistance to localised corrosion due to a modification on the microstructural evolution in the HAZ and the fusion zone during the thermal cycle involved in fusion welding. The application of EMILI reduced the size of the HAZ, limited coarsening of the ferrite grains and promoted regeneration of austenite in this zone, inducing a homogeneous passive condition of the surface. EMILI can be applied during fusion welding of structural or functional components of diverse size manufactured with duplex stainless steel designed to withstand aggressive environments such as natural seawater or marine atmospheres.

  9. The role of martensitic transformation on bimodal grain structure in ultrafine grained AISI 304L stainless steel

    Energy Technology Data Exchange (ETDEWEB)

    Sabooni, S., E-mail: s.sabooni@ma.iut.ac.ir [Department of Materials Engineering, Isfahan University of Technology, 84156-83111 Isfahan (Iran, Islamic Republic of); Karimzadeh, F.; Enayati, M.H. [Department of Materials Engineering, Isfahan University of Technology, 84156-83111 Isfahan (Iran, Islamic Republic of); Ngan, A.H.W. [Department of Mechanical Engineering, The University of Hong Kong, Pokfulam Road, Hong Kong (China)

    2015-06-11

    In the present study, metastable AISI 304L austenitic stainless steel samples were subjected to different cold rolling reductions from 70% to 93%, followed by annealing at 700 °C for 300 min to form ultrafine grained (UFG) austenite with different grain structures. Transmission electron microscopy (TEM) and nanoindentation were used to characterize the martensitic transformation, in order to relate it to the bimodal distribution of the austenite grain size after subsequent annealing. The results showed that the martensite morphology changed from lath type in the 60% rolled sample to a mixture of lath and dislocation-cell types in the higher rolling reductions. Calculation of the Gibbs free energy change during the reversion treatment showed that the reversion mechanism is shear controlled at the annealing temperature and so the morphology of the reverted austenite is completely dependent on the morphology of the deformation induced martensite. It was found that the austenite had a bimodal grain size distribution in the 80% rolled and annealed state and this is related to the existence of different types of martensite. Increasing the rolling reduction to 93% followed by annealing caused changing of the grain structure to a monomodal like structure, which was mostly covered with small grains of around 300 nm. The existence of bimodal austenite grain size in the 80% rolled and annealed 304L stainless steel led to the improvement of ductility while maintaining a high tensile strength in comparison with the 93% rolled and annealed sample.

  10. Martensite phase reversion-induced nano/ ultrafine grained AISI 304L stainless steel with magnificent mechanical properties

    Directory of Open Access Journals (Sweden)

    Mohammad Shirdel

    2015-06-01

    Full Text Available Austenitic stainless steels are extensively used in various applications requiring good corrosion resistance and formability. In the current study, the formation of nano/ ultrafine grained austenitic microstructure in a microalloyed AISI 304L stainless steel was investigated by the advanced thermomechanical process of reversion of strain-induced martensite. For this purpose, samples were subjected to heavy cold rolling to produce a nearly complete martensitic structure. Subsequently, a wide range of annealing temperatures (600 to 800°C and times (1 to 240 min were employed to assess the reversion behavior and to find the best annealing condition for the production of the nano/ultrafine grained austenitic microstructure. Microstructural characterizations have been performed using X-ray diffraction (XRD, scanning electron microscopy (SEM, and magnetic measurement, whereas the mechanical properties were assessed by tensile and hardness tests. After thermomechanical treatment, a very fine austenitic structure was obtained, which was composed of nano sized grains of ~ 85 nm in an ultrafine grained matrix with an average grain size of 480 nm. This microstructure exhibited superior mechanical properties: high tensile strength of about 1280 MPa with a desirable elongation of about 41%, which can pave the way for the application of these sheets in the automotive industry.

  11. Standard test method for electrochemical reactivation (EPR) for detecting sensitization of AISI type 304 and 304L stainless steels

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1994-01-01

    1.1 This test method covers a laboratory procedure for conducting an electrochemical reactivation (EPR) test on AISI Type 304 and 304L (UNS No. S30400 and S30403, respectively) stainless steels. This test method can provide a nondestructive means of quantifying the degree of sensitization in these steels (1, 2, 3). This test method has found wide acceptance in studies of the effects of sensitization on intergranular corrosion and intergranular stress corrosion cracking behavior (see Terminology G15). The EPR technique has been successfully used to evaluate other stainless steels and nickel base alloys (4), but the test conditions and evaluation criteria used were modified in each case from those cited in this test method. 1.2 The values stated in SI units are to be regarded as the standard. The inch-pound units given in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this...

  12. Physisorption of ammonia on AISI 304L stainless steel at different surface temperature under high vacuum conditions

    Directory of Open Access Journals (Sweden)

    A. de Castro

    2016-12-01

    Full Text Available The physisorption of ammonia molecules (sticking on the walls of a stainless steel pipe (AISI 304L has been studied at different wall temperatures (323-473K. The total amount of ammonia that is retained on the walls, once equilibrium is reached, has been measured by differentially-pumped mass spectrometry in gas exposure laboratory experiments. The results show ammonia retentions in the range of μg/cm2 resulting in a multilayer adsorption with lower amounts of stuck ammonia at higher temperatures of the stainless steel surface. The sticking coefficient follows an exponential decay evolution with time. The activation energy of the process has been estimated by an Arrhenius fit, assuming that the characteristic time for this decay is inversely proportional to the kinetic adsorption constant. A value of 0.15eV per ammonia molecule has been obtained, being in agreement with nominal values for the physisorption of small molecules or atoms (CO, N2, Ar… that can be found in the specialized literature. The implication of these results in the possible extrapolation to the ITER vacuum system under nitrogen seeded plasma operation is also addressed.

  13. Characterization Of Oxide Layers Produced On The AISI 321 Stainless Steel After Annealing

    Directory of Open Access Journals (Sweden)

    Bochnowski W.

    2015-09-01

    Full Text Available In this study, the structure, chemical composition and topography of oxide layers produced on the surface of the AISI 321 austenitic steel in the annealing process were analyzed. Heat treatment was done at 980°C temperature for 1 hour time in different conditions. The annealing was done in a ceramic furnace in oxidation atmosphere and in vacuum furnaces with cylindrical molybdenum and graphite chambers. The analysis was carried out using the following methods: a scanning electron microscope (SEM equipped with an energy-dispersive X-ray spectrometer (EDX, a transmission electron microscope (TEM equipped with an energy-dispersive X-ray spectrometer (EDX, an X-ray diffractometer (XRD, a secondary ion mass spectrometer with time-of-flight mass analyzer (TOF SIMS and an atomic force microscope (AFM. The oxide layer formed during annealing of the AISI 321 steel at 980°C consisted of sub-layers, diversified in the chemical composition. The thickness of the oxidized layer is depended on the annealing conditions. In a ceramic furnace in oxidation atmosphere, the thickness of the oxide layer was of 300-500 nm, in a vacuum furnace with molybdenum and graphite heating chambers, it ranged from 40 to 300 nm and from a few to 50 nm, respectively. TOF SIMS method allows to get average (for the surface of 100 μm × 100 μm depth profiles of concentration of particular elements and elements combined with oxygen. In oxide layers formed in vacuum furnaces there are no iron oxides. Titanium, apart from being bounded with carbon in carbides, is a component of the oxide layer formed on the surface of the AISI 321 steel.

  14. Attenuation of the in vitro neurotoxicity of 316L SS by graphene oxide surface coating.

    Science.gov (United States)

    Tasnim, Nishat; Kumar, Alok; Joddar, Binata

    2017-04-01

    A persistent theme in biomaterials research comprises of surface engineering and modification of bare metallic substrates for improved cellular response and biocompatibility. Graphene Oxide (GO), a derivative of graphene, has outstanding chemical and mechanical properties; its large surface to volume ratio, ease of surface modification and processing make GO an attractive coating material. GO-coatings have been extensively studied as biosensors. Further owing to its surface nano-architecture, GO-coated surfaces promote cell adhesion and growth, making it suitable for tissue engineering applications. The need to improve the long-term durability and therapeutic effectiveness of commercially available bare 316L stainless steel (SS) surfaces led us to adopt a polymer-free approach which is cost-effective and scalable. GO was immobilized on to 316L SS utilizing amide linkage, to generate a strongly adherent uniform coating with surface roughness. GO-coated 316L SS surfaces showed increased hydrophilicity and biocompatibility with SHSY-5Y neuronal cells, which proliferated well and showed decreased reactive oxygen species (ROS) expression. In contrast, cells did not adhere to bare uncoated 316L SS meshes nor maintain viability when cultured in the vicinity of bare meshes. Therefore the combination of the improved surface properties and biocompatibility implies that GO-coating can be utilized to overcome pertinent limitations of bare metallic 316L SS implant surfaces, especially SS neural electrodes. Also, the procedure for making GO-based protective coatings can be applied to numerous other implants where the development of such protective films is necessary.

  15. Irradiation behavior of Ti-stabilized 316L type steel

    Science.gov (United States)

    Rodchenkov, B. S.; Kalinin, G. M.; Strebkov, Yu. S.; Shamardin, V. K.; Prokhorov, V. I.; Bulanova, T. M.

    2009-04-01

    Type 316L austenitic steels are widely used for the in-vessel internal structures of fission reactors (core, core support, etc.) and for experimental irradiation facilities. The modifications of 316L Type steel (316L, 316L(N), US 316, J 316, JPCA, etc.) have been considered as structural material for International Thermonuclear Experimental Reactor (ITER). The results of investigation the irradiation behaviour of Ti-stabilized 316 L type steel (0.04 C-15 Cr-11 Ni-2.5 Mo-0.5 Ti) are presented in this work. The specimens cut out from 316L-Ti steel forging were irradiated in the SM-2 reactor up to a dose ˜4 and 10 dpa at 265 ± 15 °C. The tensile properties, fracture toughness and changes in resistance to intergranular stress corrosion cracking (IGSCC) have been investigated after irradiation. The results for Ti-stabilized 316L steel were compared with those for 316L(N)-IG steel irradiated at the same condition.

  16. Irradiation behavior of Ti-stabilized 316L type steel

    Energy Technology Data Exchange (ETDEWEB)

    Rodchenkov, B.S. [Research and Development Institute of Power Engineering (RDIPE), P.O. Box 788, 101000 Moscow (Russian Federation)], E-mail: rodchen@nikiet.ru; Kalinin, G.M.; Strebkov, Yu.S. [Research and Development Institute of Power Engineering (RDIPE), P.O. Box 788, 101000 Moscow (Russian Federation); Shamardin, V.K.; Prokhorov, V.I.; Bulanova, T.M. [State Scientific Center ' Research Institute of Atomic Reactors' , Dimitrovgrad-10, 433510 Ulyanovsk Region (Russian Federation)

    2009-04-30

    Type 316L austenitic steels are widely used for the in-vessel internal structures of fission reactors (core, core support, etc.) and for experimental irradiation facilities. The modifications of 316L Type steel (316L, 316L(N), US 316, J 316, JPCA, etc.) have been considered as structural material for International Thermonuclear Experimental Reactor (ITER). The results of investigation the irradiation behaviour of Ti-stabilized 316 L type steel (0.04 C-15 Cr-11 Ni-2.5 Mo-0.5 Ti) are presented in this work. The specimens cut out from 316L-Ti steel forging were irradiated in the SM-2 reactor up to a dose {approx}4 and 10 dpa at 265 {+-} 15 deg. C. The tensile properties, fracture toughness and changes in resistance to intergranular stress corrosion cracking (IGSCC) have been investigated after irradiation. The results for Ti-stabilized 316L steel were compared with those for 316L(N)-IG steel irradiated at the same condition.

  17. Cladding of aluminum on AISI 304L stainless steel by cold roll bonding: Mechanism, microstructure, and mechanical properties

    Energy Technology Data Exchange (ETDEWEB)

    Akramifard, H.R., E-mail: akrami.1367@ut.ac.ir [School of Metallurgy and Materials Engineering, College of Engineering, University of Tehran, P.O. Box 11155-4563, Tehran (Iran, Islamic Republic of); Mirzadeh, H., E-mail: hmirzadeh@ut.ac.ir [School of Metallurgy and Materials Engineering, College of Engineering, University of Tehran, P.O. Box 11155-4563, Tehran (Iran, Islamic Republic of); Advanced Metalforming and Thermomechanical Processing Laboratory, School of Metallurgy and Materials Engineering, University of Tehran, Tehran (Iran, Islamic Republic of); Parsa, M.H., E-mail: mhparsa@ut.ac.ir [School of Metallurgy and Materials Engineering, College of Engineering, University of Tehran, P.O. Box 11155-4563, Tehran (Iran, Islamic Republic of); Center of Excellence for High Performance Materials, School of Metallurgy and Materials Engineering, University of Tehran, Tehran (Iran, Islamic Republic of); Advanced Metalforming and Thermomechanical Processing Laboratory, School of Metallurgy and Materials Engineering, University of Tehran, Tehran (Iran, Islamic Republic of)

    2014-09-08

    The AA1050 aluminum alloy and AISI 304L stainless steel sheets were stacked together to fabricate Al/304L/Al clad sheet composites by the cold roll bonding process, which was performed at temperatures of ∼100 and 23 °C to produce austenitic and austenitic–martensitic microstructures in the AISI 304L counterpart, respectively. The peel test results showed that the threshold reduction required to make a suitable bond at room temperature is below 10%, which is significantly lower than the required reduction for cold roll bonding of Al sheets. The tearing of the Al sheet during the peel test signified that the bond strength of the roll bonded sheets by only 38% reduction has reached the strength of Al, which is a key advantage of the developed sheets. The extrusion of Al through the surface cracks and settling inside the 304L surface valleys due to strong affinity between Al and Fe was found to be the bonding mechanism. Subsequently, the interface and tensile behaviors of three-layered clad sheets after soaking at 200–600 °C for 1 h were investigated to characterize the effect of annealing treatment on the formation and thickening of intermetallic compound layer and the resultant mechanical properties. Field emission scanning electron microscopy, X-ray diffraction, and optical microscopy techniques revealed that an intermediate layer composed mainly of Al{sub 13}Fe{sub 4}, FeC and Al{sub 8}SiC{sub 7} forms during annealing at 500–600 °C. A significant drop in tensile stress–strain curves after the maximum point (UTS) was correlated to the interface debonding. It was found that the formation of intermediate layer by post heat treatment deteriorates the bond quality and encourages the debonding process. Moreover, the existence of strain-induced martensite in clad sheets was found to play a key role in the enhancement of tensile strength.

  18. Surface nanocrystallization by surface mechanical attrition treatment and its effect on structure and properties of plasma nitrided AISI 321 stainless steel

    Energy Technology Data Exchange (ETDEWEB)

    Lin Yimin [State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, 18 Middle Tianshui Road, Lanzhou 730000 (China) and Graduate School of the Chinese Academy of Sciences, Beijing 100039 (China)]. E-mail: linyimin_2001@yahoo.com.cn; Lu Jian [LASMIS, University of Technology of Troyes, 10000 Troyes (France); Wang Liping [State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, 18 Middle Tianshui Road, Lanzhou 730000 (China); Graduate School of the Chinese Academy of Sciences, Beijing 100039 (China); Xu Tao [State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, 18 Middle Tianshui Road, Lanzhou 730000 (China); Xue Qunji [State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, 18 Middle Tianshui Road, Lanzhou 730000 (China)]. E-mail: qjxue@ns.lzb.ac.cn

    2006-12-15

    A plastic deformation surface layer with nanocrystalline grains was produced on AISI 321 austenitic stainless steel by means of surface mechanical attrition treatment (SMAT). Low-temperature nitriding of SMAT and un-SMAT AISI 321 stainless steel was carried out in pulsed-DC glow discharge. The effect of SMAT pretreatment on the microstructure and properties of the stainless steel were investigated using X-ray diffraction, scanning electron microscopy, transmission electron microscopy, Vickers hardness tester and UMT-2MT tribometer. The results show that the plasma nitriding of AISI 321 steel can be enhanced considerably by means of SMAT process before nitriding, and a much thicker nitrogen diffusion layer with higher hardness was obtained for the SMAT samples when compared with un-SMAT samples. In addition, the wear resistance and load capacity of the nitrided layers on the SMAT samples was much higher than that of the un-SMAT samples due to the thicker S phase case and the gradient nitrogen diffusion layer.

  19. Preliminary Comparison of Properties between Ni-electroplated Stainless Steel Parts Fabricated with Laser Additive Manufacturing and Conventional Machining

    Science.gov (United States)

    Mäkinen, Mika; Jauhiainen, Eeva; Matilainen, Ville-Pekka; Riihimäki, Jaakko; Ritvanen, Jussi; Piili, Heidi; Salminen, Antti

    Laser additive manufacturing (LAM) is a fabrication technology, which enables production of complex parts from metallic materials with mechanical properties comparable to those of conventionally machined parts. These LAM parts are manufactured via melting metallic powder layer by layer with laser beam. Aim of this study is to define preliminarily the possibilities of using electroplating to supreme surface properties. Electrodeposited nickel and chromium as well as electroless (autocatalytic) deposited nickel was used to enhance laser additive manufactured and machined parts properties, like corrosion resistance, friction and wearing. All test pieces in this study were manufactured with a modified research AM equipment, equal to commercial EOS M series. The laser system used for tests was IPG 200 W CW fiber laser. The material used in this study for additive manufacturing was commercial stainless steel powder grade named SS316L. This SS316L is not equal to AISI 316L grade, but commercial name of this kind of powder is widely known in additive manufacturing as SS316L. Material used for fabrication of comparison test pieces (i.e. conventionally manufactured) was AISI 316L stainless steel bar. Electroplating was done in matrix cell and electroless was done in plastic sink properties of plated parts were tested within acetic acid salt spray corrosion chamber (AASS, SFS-EN-ISO 9227 standard). Adhesion of coating, friction and wearing properties were tested with Pin-On-Rod machine. Results show that in these preliminary tests, LAM parts and machined parts have certain differences due to manufacturing route and surface conditions. These have an effect on electroplated and electroless parts features on adhesion, corrosion, wearing and friction. However, further and more detailed studies are needed to fully understand these phenomena.

  20. Corrosion, haemocompatibility and bacterial adhesion behaviour of TiZrN-coated 316L SS for bioimplants

    Indian Academy of Sciences (India)

    Gobi Saravanan Kaliaraj; Vinita Vishwakarma; Ananthakumar Ramadoss; D Ramachandran; Arul Maximus Rabel

    2015-08-01

    TiZrN coating was deposited on 316L stainless steel (SS) by the reactive magnetron co-sputtering technique. Cubic phase of TiZrN with uniform surface morphology was observed by X-ray diffraction and atomic force microscopy. Bacterial adhesion, haemocompatibility and corrosion behaviour of TiZrN coating were examined in order to evaluate the coating’s compatibility for ideal implant. Results revealed that TiZrN coatings exhibited less bacterial attachment against Staphylococcus aureus and Escherichia coli bacteria, negligible platelets activation and superior corrosion resistance than the uncoated 316L SS.

  1. Improvement of adhesion and barrier properties of biomedical stainless steel by deposition of YSZ coatings using RF magnetron sputtering

    Energy Technology Data Exchange (ETDEWEB)

    Sánchez-Hernández, Z.E. [Instituto Politécnico Nacional, CICATA-Altamira, Grupo CIAMS, Km 14.5, Carretera Tampico-Puerto Industrial Altamira, C. P. 89600, Altamira, Tamps, México (Mexico); CICATA—Altamira, IPN. Grupo CIAMS, Km 14.5, Carretera Tampico-Puerto Industrial Altamira, C. P. 89600, Altamira, Tamps, México (Mexico); Domínguez-Crespo, M.A., E-mail: mdominguezc@ipn.mx [Instituto Politécnico Nacional, CICATA-Altamira, Grupo CIAMS, Km 14.5, Carretera Tampico-Puerto Industrial Altamira, C. P. 89600, Altamira, Tamps, México (Mexico); Torres-Huerta, A.M.; Onofre-Bustamante, E. [Instituto Politécnico Nacional, CICATA-Altamira, Grupo CIAMS, Km 14.5, Carretera Tampico-Puerto Industrial Altamira, C. P. 89600, Altamira, Tamps, México (Mexico); Andraca Adame, J. [Instituto Politécnico Nacional, Centro de Nanociencias Micro y Nanotecnologías, Departamento de DRX, C. P. 07300, Mexico, DF, México (Mexico); Dorantes-Rosales, H. [Instituto Politécnico Nacional, ESIQIE, Departamento de Metalurgia, C. P. 07300 Mexico, DF, México (Mexico)

    2014-05-01

    The AISI 316L stainless steel (SS) has been widely used in both artificial knee and hip joints in biomedical applications. In the present study, yttria stabilized zirconia (YSZ, ZrO{sub 2} + 8% Y{sub 2}O{sub 3}) films were deposited on AISI 316L SS by radio-frequency magnetron sputtering using different power densities (50–250 W) and deposition times (30–120 min) from a YSZ target. The crystallographic orientation and surface morphology were studied using X-ray diffraction (XRD), scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The effects of the surface modification on the corrosion performance of AISI 316L SS were evaluated in phosphate buffered saline (PBS) solution using an electrochemical test on both the virgin and coated samples. The YSZ coatings have a (111) preferred orientation during crystal growth along the c-axis for short deposition times (30–60 min), whereas a polycrystalline structure forms during deposition times from 90 to 120 min. The corrosion protective character of the YSZ coatings depends on the crystal size and film thickness. A significant increase in adhesion and corrosion resistance by at least a factor of 46 and a higher breakdown potential were obtained for the deposited coatings at 200 W (120 min). - Highlights: • Well-formed and protective YSZ coatings were achieved on AISI 316L SS substrates. • Films grown at high power and long deposition time have polycrystalline structures. • The crystal size varies from ∼ 5 to 30 nm as both power and deposition time increased. • The differences of corrosion resistance are attributed to internal film structure.

  2. 316L-20G双金属复合管焊缝组织元素扩散分析%Analysis on weld metal and element migration of 316L-20G clad pipe

    Institute of Scientific and Technical Information of China (English)

    范兆廷; 张胜涛; 殷林亮; 刘佳; 戴志向

    2012-01-01

    The proliferation of weld and major alloying elements are studied and analyzed by scanning the EDS element of 316L/20G clad pipe weld joint,316L substrate and 20G steel,and by scanning the electron microscopy and the energy spectrum analysis of 316L-weld zone and 20G steel-weld zone.The results show that the alloying elements in the weld transition layer are diluted by carbon steel,and the carbon atoms spread to the 316L and weld,while alloying elements in the 316L and wire,such as Cr,Ni,penetrate to the carbon steel,but the transition layer plays a good role in isolation,resulting in 316L stainless steel alloy element content is not significantly reduced,maintaining the 316L base metal resistant to corrosion.%通过对20G钢内衬316L金属复合管的焊缝区、316L基体以及20G钢进行EDS元素扫描,再采用扫描电镜对316L焊缝区、20G钢焊缝区进行线扫描分析,对焊缝组织主要合金元素的扩散进行了研究。结果表明:焊缝过渡层中合金元素被碳钢稀释,碳原子向316L和焊缝扩散,同时316L和焊丝中的合金元素Cr、Ni也向碳钢中渗透,但过渡层起到了良好的隔离作用,致使316L不锈钢金属中合金元素含量没有明显降低,保持了316L母材耐腐蚀性能。

  3. Effect of laser beam position on mechanical properties of F82H/SUS316L butt-joint welded by fiber laser

    Energy Technology Data Exchange (ETDEWEB)

    Serizawa, Hisashi, E-mail: serizawa@jwri.osaka-u.ac.jp [Joining and Welding Research Institute, Osaka University, 11-1 Mihogaoka, Ibaraki, Osaka 567-0047 (Japan); Mori, Daiki; Ogiwara, Hiroyuki; Mori, Hiroaki [Graduate School of Engineering, Osaka University, 2-1 Yamadaoka, Suita, Osaka 565-0871 (Japan)

    2014-10-15

    Highlights: • The micro hardness of weld metal in F82H/SUS316L joint partially decreases after PWHT by shifting beam position to SUS316L. • Charpy impact energy of F82H/SUS316L joint obviously increases after PWHT due to the release of residual stress. • The tensile strength of weld metal in F82H/SUS316L joint is higher than that of SUS316L. • The fiber laser welding seems to be one of the most candidate methods to join between F82H and SUS316L pipes practically. - Abstract: A dissimilar butt-joint between reduced activation ferritic/martensitic steel F82H and SUS316L austenitic stainless steel was made by 4 kW fiber laser and the influence of laser beam position on its mechanical properties before and after post-weld heat treatment (PWHT) was examined at room temperature. From the nano-indentation measurements and the microstructural observations, it is found that the micro hardness of weld metal partially decreases after PWHT by shifting beam position to SUS316L because its phase seems to move from only the martensitic phase to the mixture of austenitic and martensitic phases. In addition, Charpy impact test suggests that the impact energy slightly increases by shifting beam position before PWHT and obviously increases after PWHT due to the release of residual stress. Moreover, the tensile test indicates that the tensile strength of weld metal is higher than that of SUS316L and the fracture occurs at the base metal of SUS316L r