WorldWideScience

Sample records for airway pressure breathing

  1. Comparison of nasal continuous positive airway pressure delivered by seven ventilators using simulated neonatal breathing.

    Science.gov (United States)

    Drevhammar, Thomas; Nilsson, Kjell; Zetterström, Henrik; Jonsson, Baldvin

    2013-05-01

    Nasal continuous positive airway pressure (NCPAP) is an established treatment for respiratory distress in neonates. Most modern ventilators are able to provide NCPAP. There have been no large studies examining the properties of NCPAP delivered by ventilators. The aim of this study was to compare pressure stability and imposed work of breathing (iWOB) for NCPAP delivered by ventilators using simulated neonatal breathing. Experimental in vitro study. Research laboratory in Sweden. None. Neonatal breathing was simulated using a mechanical lung simulator. Seven ventilators were tested at different CPAP levels using two breath profiles. Pressure stability and iWOB were determined. Results from three ventilators revealed that they provided a slight pressure support. For these ventilators, iWOB could not be calculated. There were large differences in pressure stability and iWOB between the tested ventilators. For simulations using the 3.4-kg breath profile, the pressure swings around the mean pressure were more than five times greater, and iWOB more than four times higher, for the system with the highest measured values compared with the system with the lowest. Overall, the Fabian ventilator was the most pressure stable system. Evita XL and SERVO-i were found more pressure stable than Fabian in some simulations. The results for iWOB were in accordance with pressure stability for systems that allowed determination of this variable. Some of the tested ventilators unexpectedly provided a minor degree of pressure support. In terms of pressure stability, we have not found any advantages of ventilators as a group compared with Bubble CPAP, Neopuff, and variable flow generators that were tested in our previous study. The variation between individual systems is great within both categories. The clinical importance of these findings needs further investigation.

  2. Treatment of sleep-disordered breathing with positive airway pressure devices: technology update.

    Science.gov (United States)

    Johnson, Karin Gardner; Johnson, Douglas Clark

    2015-01-01

    Many types of positive airway pressure (PAP) devices are used to treat sleep-disordered breathing including obstructive sleep apnea, central sleep apnea, and sleep-related hypoventilation. These include continuous PAP, autoadjusting CPAP, bilevel PAP, adaptive servoventilation, and volume-assured pressure support. Noninvasive PAP has significant leak by design, which these devices adjust for in different manners. Algorithms to provide pressure, detect events, and respond to events vary greatly between the types of devices, and vary among the same category between companies and different models by the same company. Many devices include features designed to improve effectiveness and patient comfort. Data collection systems can track compliance, pressure, leak, and efficacy. Understanding how each device works allows the clinician to better select the best device and settings for a given patient. This paper reviews PAP devices, including their algorithms, settings, and features.

  3. Treatment of sleep-disordered breathing with positive airway pressure devices: technology update

    Directory of Open Access Journals (Sweden)

    Johnson KG

    2015-10-01

    Full Text Available Karin Gardner Johnson, Douglas Clark Johnson Department of Medicine, Baystate Medical Center, Springfield, MA, USA Abstract: Many types of positive airway pressure (PAP devices are used to treat sleep-disordered breathing including obstructive sleep apnea, central sleep apnea, and sleep-related hypoventilation. These include continuous PAP, autoadjusting CPAP, bilevel PAP, adaptive servoventilation, and volume-assured pressure support. Noninvasive PAP has significant leak by design, which these devices adjust for in different manners. Algorithms to provide pressure, detect events, and respond to events vary greatly between the types of devices, and vary among the same category between companies and different models by the same company. Many devices include features designed to improve effectiveness and patient comfort. Data collection systems can track compliance, pressure, leak, and efficacy. Understanding how each device works allows the clinician to better select the best device and settings for a given patient. This paper reviews PAP devices, including their algorithms, settings, and features. Keywords: BiPAP, CPAP, iVAPS, AVAPS, ASV, positive pressure respiration, instrumentation, treatment algorithm

  4. Continuous positive airway pressure breathing increases cranial spread of sensory blockade after cervicothoracic epidural injection of lidocaine.

    NARCIS (Netherlands)

    Visser, W.A.; Eerd, M.J. van; Seventer, R. van; Gielen, M.J.M.; Giele, J.L.P.; Scheffer, G.J.

    2007-01-01

    BACKGROUND: Continuous positive airway pressure (CPAP) increases the caudad spread of sensory blockade after low-thoracic epidural injection of lidocaine. We hypothesized that CPAP would increase cephalad spread of blockade after cervicothoracic epidural injection. METHODS: Twenty patients with an

  5. Influence of upper body position on middle cerebral artery blood velocity during continuous positive airway pressure breathing

    DEFF Research Database (Denmark)

    Højlund Rasmussen, J; Mantoni, T; Belhage, B

    2007-01-01

    Continuous positive airway pressure (CPAP) is a treatment modality for pulmonary oxygenation difficulties. CPAP impairs venous return to the heart and, in turn, affects cerebral blood flow (CBF) and augments cerebral blood volume (CBV). We considered that during CPAP, elevation of the upper body ...

  6. Mechanical breath profile of airway pressure release ventilation: the effect on alveolar recruitment and microstrain in acute lung injury.

    Science.gov (United States)

    Kollisch-Singule, Michaela; Emr, Bryanna; Smith, Bradford; Roy, Shreyas; Jain, Sumeet; Satalin, Joshua; Snyder, Kathy; Andrews, Penny; Habashi, Nader; Bates, Jason; Marx, William; Nieman, Gary; Gatto, Louis A

    2014-11-01

    Improper mechanical ventilation settings can exacerbate acute lung injury by causing a secondary ventilator-induced lung injury. It is therefore important to establish the mechanism by which the ventilator induces lung injury to develop protective ventilation strategies. It has been postulated that the mechanism of ventilator-induced lung injury is the result of heterogeneous, elevated strain on the pulmonary parenchyma. Acute lung injury has been associated with increases in whole-lung macrostrain, which is correlated with increased pathology. However, the effect of mechanical ventilation on alveolar microstrain remains unknown. To examine whether the mechanical breath profile of airway pressure release ventilation (APRV), consisting of a prolonged pressure-time profile and brief expiratory release phase, reduces microstrain. In a randomized, nonblinded laboratory animal study, rats were randomized into a controlled mandatory ventilation group (n = 3) and an APRV group (n = 3). Lung injury was induced by polysorbate lavage. A thoracotomy was performed and an in vivo microscope was placed on the lungs to measure alveolar mechanics. In the controlled mandatory ventilation group, multiple levels of positive end-expiratory pressure (PEEP; 5, 10, 16, 20, and 24 cm H2O) were tested. In the APRV group, decreasing durations of expiratory release (time at low pressure [T(low)]) were tested. The T(low) was set to achieve ratios of termination of peak expiratory flow rate (T-PEFR) to peak expiratory flow rate (PEFR) of 10%, 25%, 50%, and 75% (the smaller this ratio is [ie, 10%], the more time the lung is exposed to low pressure during the release phase, which decreases end-expiratory lung volume and potentiates derecruitment). Alveolar perimeters were measured at peak inspiration and end expiration using digital image analysis, and strain was calculated by normalizing the change in alveolar perimeter length to the original length. Macrostrain was measured by volume

  7. Continuous Positive Airway Pressure (CPAP)

    Science.gov (United States)

    ... ENT Doctor Near You Continuous Positive Airway Pressure (CPAP) Continuous Positive Airway Pressure (CPAP) Patient Health Information ... relations staff at newsroom@entnet.org . What Is CPAP? The most common and effective nonsurgical treatment for ...

  8. Work of breathing as a tool to diagnose severe fixed upper airway obstruction.

    Science.gov (United States)

    Khirani, S; Pierrot, S; Leboulanger, N; Ramirez, A; Breton, D; Couloigner, V; Fauroux, B

    2014-03-01

    A 4-year-old girl with bilateral vocal fold palsy was successfully decannulated from tracheotomy after seven laryngeal procedures. But an important stridor and dyspnea recurred 13 months after decannulation. Nocturnal gas exchange was normal but her daytime work of breathing was increased by fourfold, without any beneficial effect of nasal noninvasive continuous positive airway pressure ventilation (CPAP), reflecting a severe fixed airway obstruction. Endoscopic examination confirmed the work of breathing findings showing glottic and supraglottic stenosis. This upper airway obstruction was successfully treated with a recannulation. In conclusion, the major message of this case report is that measurement of the work of breathing was able to document the "fixed" nature of the airway obstruction, by showing no improvement even with highest tolerated levels of nasal CPAP. As such, the work of breathing may be proposed as a screening tool to quantify and assess the reversibility of severe upper airway obstruction in children. © 2013 Wiley Periodicals, Inc.

  9. Continuous positive airway pressure breathing increases the spread of sensory blockade after low-thoracic epidural injection of lidocaine.

    NARCIS (Netherlands)

    Visser, W.A.; Gielen, M.J.M.; Giele, J.L.P.

    2006-01-01

    Factors affecting the distribution of sensory blockade after epidural injection of local anesthetics remain incompletely clarified. To evaluate if increasing intrathoracic pressure affects the spread of thoracic epidural anesthesia, we randomized 20 patients who received an epidural catheter at the

  10. The role of arterial chemoreceptors in the breath-by-breath augmentation of inspiratory effort in rabbits during airway occlusion or elastic loading.

    Science.gov (United States)

    Callanan, D; Read, D J

    1974-08-01

    1. The breath-by-breath augmentation of inspiratory effort in the five breaths following airway occlusion or elastic loading was assessed in anaesthetized rabbits from changes of airway pressure, diaphragm e.m.g. and lung volume.2. When the airway was occluded in animals breathing air, arterial O(2) tension fell by 20 mmHg and CO(2) tension rose by 7 mmHg within the time of the first five loaded breaths.3. Inhalation of 100% O(2) or carotid denervation markedly reduced the breath-by-breath progression but had little or no effect on the responses at the first loaded breath.4. These results indicate that the breath-by-breath augmentation of inspiratory effort following addition of a load is mainly due to asphyxial stimulation of the carotid bodies, rather than to the gradual emergence of a powerful load-compensating reflex originating in the chest-wall, as postulated by some workers.5. The small residual progression seen in animals breathing 100% O(2) or following carotid denervation was not eliminated (a) by combining these procedures or (b) by addition of gas to the lungs to prevent the progressive lung deflation which occurred during airway occlusion.6. Bilateral vagotomy, when combined with carotid denervation, abolished the residual breath-by-breath progression of inspiratory effort.

  11. COMPARISON OF 3 NORMAL BREATHING TECHNIQUES TO ASSESS REVERSIBILITY OF AIRWAY-OBSTRUCTION

    NARCIS (Netherlands)

    GIMENO, F; POSTMA, DS; VANALTENA, R

    1992-01-01

    Measurement of forced expiratory volume in one second (FEV1) is generally used to assess airway obstruction. Function tests during normal breathing are used as complementary tests as well as alternatives. Studies have been done comparing the esophageal pressure method with body plethysmography, and

  12. Effects of Depth of Propofol and Sevoflurane Anesthesia on Upper Airway Collapsibility, Respiratory Genioglossus Activation, and Breathing in Healthy Volunteers

    DEFF Research Database (Denmark)

    Simons, Jeroen C P; Pierce, Eric; Diaz-Gil, Daniel

    2016-01-01

    . Measurements included bispectral index, genioglossus electromyography, ventilation, hypopharyngeal pressure, upper airway closing pressure, and change in end-expiratory lung volume during mask pressure drops. RESULTS: A total of 393 attempted breaths during occlusion maneuvers were analyzed. Upper airway......BACKGROUND: Volatile anesthetics and propofol impair upper airway stability and possibly respiratory upper airway dilator muscle activity. The magnitudes of these effects have not been compared at equivalent anesthetic doses. We hypothesized that upper airway closing pressure is less negative...... closing pressure was significantly less negative at deep versus shallow anesthesia (-10.8 ± 4.5 vs. -11.3 ± 4.4 cm H2O, respectively [mean ± SD]) and correlated with the bispectral index (P airway at deep anesthesia. Respiratory genioglossus activity during airway...

  13. Increased airway reactivity in a neonatal mouse model of Continuous Positive Airway Pressure (CPAP)

    OpenAIRE

    Mayer, Catherine A.; Martin, Richard J.; MacFarlane, Peter M.

    2015-01-01

    Background Continuous positive airway pressure (CPAP) is a primary form of respiratory support used in the intensive care of preterm infants, but its long-term effects on airway (AW) function are unknown. Methods We developed a neonatal mouse model of CPAP treatment to determine whether it modifies later AW reactivity. Un-anesthetized spontaneously breathing mice were fitted with a mask to deliver CPAP (6cmH2O, 3hrs/day) for 7 consecutive days starting at postnatal day 1. Airway reactivity to...

  14. Positive airway pressure treatment

    Science.gov (United States)

    ... it. After using PAP regularly, you may notice: Better concentration and memory Feeling more alert and less sleepy during the day Improved sleep for your bed partner Being more productive at ... and a better mood Normal sleep patterns Lower blood pressure (in ...

  15. Improvised bubble continuous positive airway pressure (BCPAP ...

    African Journals Online (AJOL)

    Improvised bubble continuous positive airway pressure (BCPAP) device at the National Hospital Abuja gives immediate improvement in respiratory rate and oxygenation in neonates with respiratory distress.

  16. Pressure breathing in fighter aircraft for G accelerations and loss of cabin pressurization at altitude--a brief review.

    Science.gov (United States)

    Lauritzsen, Lars P; Pfitzner, John

    2003-04-01

    The purpose of this brief review is to outline the past and present use of pressure breathing, not by patients but by fighter pilots. Of the historical and recent references quoted, most are from aviation-medicine journals that are not often readily available to anesthesiologists. Pressure breathing at moderate levels of airway pressure gave World War II fighter pilots a tactical altitude advantage. With today's fast and highly maneuverable jet fighters, very much higher airway pressures of the order of 8.0 kPa (identical with 60 mmHg) are used. They are used in conjunction with a counterpressure thoracic vest and an anti-G suit for the abdomen and lower body. Pressurization is activated automatically in response to +Gz accelerations, and to a potentially catastrophic loss of cabin pressurization at altitude. During +Gz accelerations, pressure breathing has been shown to maintain cerebral perfusion by raising the systemic arterial pressure, so increasing the level of G-tolerance that is afforded by the use of anti-G suits and seat tilt-back angles alone. This leaves the pilot less reliant on rigorous, and potentially distracting, straining maneuvers. With loss of cabin pressurization at altitude, pressure breathing of 100% oxygen at high airway pressures enables the pilot's alveolar PO(2) to be maintained at a safe level during emergency descent. Introduced in military aviation, pressure breathing for G-tolerance and pressure breathing for altitude presented as concepts that may be of general physiological interest to many anesthesiologists.

  17. Nasal continuous positive airway pressure

    DEFF Research Database (Denmark)

    Scholze, Alexandra; Lamwers, Stephanie; Tepel, Martin

    2012-01-01

    Obstructive sleep apnoea (OSA) is linked to increased cardiovascular risk. This risk can be reduced by nasal continuous positive airway pressure (nCPAP) treatment. As OSA is associated with an increase of several vasoconstrictive factors, we investigated whether nCPAP influences the digital volume...... pulse wave. We performed digital photoplethysmography during sleep at night in 94 consecutive patients who underwent polysomnography and 29 patients treated with nCPAP. Digital volume pulse waves were obtained independently of an investigator and were quantified using an algorithm for continuous.......01; n = 94) and the arousal index (Spearman correlation, r = 0.21; p CPAP treatment, the AHI was significantly reduced from 27 ± 3 events · h(-1) to 4 ± 2 events · h(-1) (each n = 29; p

  18. Coaxial Tubing Systems Increase Artificial Airway Resistance and Work of Breathing.

    Science.gov (United States)

    Wenzel, Christin; Schumann, Stefan; Spaeth, Johannes

    2017-09-01

    Tubing systems are an essential component of the ventilation circuit, connecting the ventilator to the patient's airways. Coaxial tubing systems incorporate the inspiratory tube within the lumen of the expiratory one. We hypothesized that by design, these tubing systems increase resistance to air flow compared with conventional ones. We investigated the flow-dependent pressure gradient across coaxial, conventional disposable, and conventional reusable tubing systems from 3 different manufacturers. Additionally, the additional work of breathing and perception of resistance during breathing through the different devices were determined in 18 healthy volunteers. The pressure gradient across coaxial tubing systems was up to 6 times higher compared with conventional ones (1.90 ± 0.03 cm H 2 O vs 0.34 ± 0.01 cm H 2 O, P tubing systems, accordingly. Our findings suggest that the use of coaxial tubing systems should be carefully considered with respect to their increased resistance. Copyright © 2017 by Daedalus Enterprises.

  19. Continuous Positive Airway Pressure Strategies with Bubble Nasal Continuous Positive Airway Pressure: Not All Bubbling Is the Same: The Seattle Positive Airway Pressure System.

    Science.gov (United States)

    Welty, Stephen E

    2016-12-01

    Premature neonates are predisposed to complications, including bronchopulmonary dysplasia (BPD). BPD is associated with long-term pulmonary and neurodevelopmental consequences. Noninvasive respiratory support with nasal continuous positive airway pressure (CPAP) has been recommended strongly by the American Academy of Pediatrics. However, CPAP implementation has shown at least a 50% failure rate. Enhancing nasal CPAP effectiveness may decrease the need for mechanical ventilation and reduce the incidence of BPD. Bubble nasal CPAP is better than nasal CPAP using mechanical devices and the bubbling provides air exchange in distal respiratory units. The Seattle PAP system reduces parameters that assess work of breathing. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Continuous positive airway pressure (CPAP).

    Science.gov (United States)

    Sahni, R; Wung, J T

    1998-01-01

    Progress in neonatal intensive care is closely linked to improvements in the management of respiratory failure in small infants. This applies to the care of the preterm infants with immature lungs, and also to treatment of the preterm or full term infants with specific diseases that are associated with respiratory failure. Respiratory distress of the newborn continues to account for significant morbidity in the intensive care unit. The spectrum of disease ranges from mild distress to severe respiratory failure requiring varying degrees of support. The current modalities of ventilatory assistance range from the more benign continuous positive airway pressure (CPAP) to conventional mechanical ventilation, and on to high frequency ventilation. It is a reasonable supposition that the type of ventilatory assistance provided to these infants should be graded according to the severity of the disease. However, the principal objective in selecting the mode of respiratory support should be to use a modality which results in minimal volo- or barotrauma to the infant. The following detailed description on CPAP explains its physiological effects, delivery system, indications for use, application, maintenance, and associated complications. The equipment described is simple to use, has a greater cost benefit, and has a more universal application, which is of help to smaller units including those in the developing parts of the world. We have also included our institutional clinical experience of CPAP usage in very low birth weight infants from the periods before and after commercial availability of surfactant in the United States.

  1. Proportional positive airway pressure: a new concept to treat obstructive sleep apnoea.

    Science.gov (United States)

    Juhász, J; Becker, H; Cassel, W; Rostig, S; Peter, J H

    2001-03-01

    Proportional positive airway pressure (PPAP) was designed to optimize airway pressure for the therapy of obstructive sleep apnoea (OSA). In a randomized crossover prospective study, the clinical feasibility of PPAP and its immediate effects on the breathing disorder and sleep in comparison with continuous positive airway pressure (CPAP) was evaluated. Twelve patients requiring CPAP therapy underwent CPAP and PPAP titration in a random order. Obstructive and mixed respiratory events could be completely abolished with both forms of treatment. This efficacy could be achieved at a significantly lower mean mask pressure during PPAP titration (8.45+/-2.42 cmH2O) compared to CPAP (9.96+/-2.7 cmH2O) (p=0.002). The mean minimal arterial oxygen saturation (Sa,O2) (82.8+/-6.5%) on the diagnostic night increased significantly (pPPAP titration. Total sleep time, slow wave sleep and rapid eye movement (REM) sleep increased significantly by the same amount during both CPAP and PPAP titration (pPPAP titration night, four patients did not have a preference, and two patients preferred CPAP. The present data show that proportional positive airway pressure is as effective as continuous positive airway pressure in eliminating obstructive events and has the same immediate effect on sleep. The lower average mask pressure during proportional positive airway pressure implies potential advantages compared to continuous positive airway pressure. Proportional positive airway pressure presents a new effective therapeutic approach to obstructive sleep apnoea.

  2. Improvised bubble continuous positive airway pressure

    African Journals Online (AJOL)

    PROF. EZECHUKWU

    2014-08-15

    Aug 15, 2014 ... Abstract: Background: Prematur- ity accounts for 25% of Neonatal mortality in Nigeria and Respira- tory Distress Syndrome is respon- sible for half of these deaths. Introducing continuous positive airway pressure for the treatment of RDS in Nigeria where health care financing is predominantly out-of-pocket ...

  3. Effects of condensate in the exhalation limb of neonatal circuits on airway pressure during bubble CPAP.

    Science.gov (United States)

    Youngquist, Tiffany M; Richardson, C Peter; Diblasi, Robert M

    2013-11-01

    Bubble CPAP is frequently used in spontaneously breathing infants with lung disease. Often bubble CPAP systems lack pressure alarms and pressure-release valves. We observed a large volume of condensate in the exhalation limb of a patient circuit and conducted a series of experiments to test the hypothesis that accumulated condensate could affect delivered pressures. An anatomically accurate nasal airway model of a preterm infant was attached to a spontaneously breathing lung model. A bubble CPAP system was attached to the nasal airway with bi-nasal short prongs, and the rate of fluid condensation was measured. Next, tracheal pressures were monitored digitally to detect changes in airway pressure related to condensate accumulation. Measurements were obtained with volumes of 0, 5, 10, 15, and 20 mL of water in the exhalation limb, at flows of 4, 6, 8, and 10 L/min. Measurements with 20 mL in the exhalation limb were recorded with and without a pressure-relief valve in the circuit. The rate of condensate accumulation was 3.8 mL/h. At volumes of ≥ 10 mL, noticeable alterations in the airway pressure waveforms and significant increases in mean tracheal pressure were observed. The pressure-relief valve effectively attenuated peak tracheal pressure, but only decreased mean pressure by 0.5-1.5 cm H2O. Condensate in the exhalation limb of the patient circuit during bubble CPAP can significantly increase pressure delivered to the patient. The back and forth movement of this fluid causes oscillations in airway pressure that are much greater than the oscillations created by gas bubbling out the exhalation tube into the water bath. We recommend continuously monitoring pressure at the nasal airway interface, placing an adjustable pressure-relief valve in the circuit, set to 5 cm H2O above the desired mean pressure, and emptying fluid from the exhalation limb every 2-3 hours.

  4. The relationship between partial upper-airway obstruction and inter-breath transition period during sleep.

    Science.gov (United States)

    Mann, Dwayne L; Edwards, Bradley A; Joosten, Simon A; Hamilton, Garun S; Landry, Shane; Sands, Scott A; Wilson, Stephen J; Terrill, Philip I

    2017-10-01

    Short pauses or "transition-periods" at the end of expiration and prior to subsequent inspiration are commonly observed during sleep in humans. However, the role of transition periods in regulating ventilation during physiological challenges such as partial airway obstruction (PAO) has not been investigated. Twenty-nine obstructive sleep apnea patients and eight controls underwent overnight polysomnography with an epiglottic catheter. Sustained-PAO segments (increased epiglottic pressure over ≥5 breaths without increased peak inspiratory flow) and unobstructed reference segments were manually scored during apnea-free non-REM sleep. Nasal pressure data was computationally segmented into inspiratory (T I , shortest period achieving 95% inspiratory volume), expiratory (T E , shortest period achieving 95% expiratory volume), and inter-breath transition period (T Trans , period between T E and subsequent T I ). Compared with reference segments, sustained-PAO segments had a mean relative reduction in T Trans (-24.7±17.6%, P<0.001), elevated T I (11.8±10.5%, P<0.001), and a small reduction in T E (-3.9±8.0, P≤0.05). Compensatory increases in inspiratory period during PAO are primarily explained by reduced transition period and not by reduced expiratory period. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Increased airway reactivity in a neonatal mouse model of Continuous Positive Airway Pressure (CPAP)

    Science.gov (United States)

    Mayer, Catherine A.; Martin, Richard J.; MacFarlane, Peter M.

    2015-01-01

    Background Continuous positive airway pressure (CPAP) is a primary form of respiratory support used in the intensive care of preterm infants, but its long-term effects on airway (AW) function are unknown. Methods We developed a neonatal mouse model of CPAP treatment to determine whether it modifies later AW reactivity. Un-anesthetized spontaneously breathing mice were fitted with a mask to deliver CPAP (6cmH2O, 3hrs/day) for 7 consecutive days starting at postnatal day 1. Airway reactivity to methacholine was assessed using the in vitro living lung slice preparation. Results One week of CPAP increased AW responsiveness to methacholine in male, but not female mice, compared to untreated control animals. The AW hyper-reactivity of male mice persisted for 2 weeks (at P21) after CPAP treatment ended. 4 days of CPAP, however, did not significantly increase AW reactivity. Females also exhibited AW hyper-reactivity at P21, suggesting a delayed response to early (7 days) CPAP treatment. The effects of 7 days of CPAP on hyper-reactivity to methacholine were unique to smaller AWs whereas larger ones were relatively unaffected. Conclusion These data may be important to our understanding of the potential long-term consequences of neonatal CPAP therapy used in the intensive care of preterm infants. PMID:25950451

  6. Effect of Filters on the Noise Generated by Continuous Positive Airway Pressure Delivered via a Helmet

    Directory of Open Access Journals (Sweden)

    Ricardo Hernández-Molina

    2017-01-01

    Full Text Available Introduction: One of the problems that the delivery of continuous positive airway pressure (CPAP via a helmet poses is the generation of noise. The objective of our study was to assess the effect that the use of filter has on sound pressure levels generated by the delivery of positive airway pressure at different gas flow rates. Materials and Methods: Sound pressure levels generated by neonatal helmet CPAP delivery were measured at different gas flows (20, 30, and 40 l/min with and without a breathing filter. Noise intensity was measured by installing microphones in the inner ear of dummy heads wearing helmets. Results: The sound pressure level increased by 38% at a gas flow of 40 l/min, as compared to a gas flow of 20 l/min {74 dBA [interquartile range (IQR 2,2] vs 52 dBA (IQR 5,9, respectively}. Using the breathing filter as a diffuser has a variety of effects on sound pressure levels according to the gas flow rate. Conclusion: The intensity of the noise generated by helmet delivery of positive airway pressure depends on the type of helmet used, gas flow, and use or not of a diffuser filter. Breathing filters with gas flows over 30 l/min might not be recommended since they would not attenuate but will rather amplify sound pressure.

  7. Within-breath respiratory impedance and airway obstruction in patients with chronic obstructive pulmonary disease.

    Science.gov (United States)

    Silva, Karla Kristine Dames da; Faria, Alvaro Camilo Dias; Lopes, Agnaldo José; Melo, Pedro Lopes de

    2015-07-01

    Recent work has suggested that within-breath respiratory impedance measurements performed using the forced oscillation technique may help to noninvasively evaluate respiratory mechanics. We investigated the influence of airway obstruction on the within-breath forced oscillation technique in smokers and chronic obstructive pulmonary disease patients and evaluated the contribution of this analysis to the diagnosis of chronic obstructive pulmonary disease. Twenty healthy individuals and 20 smokers were assessed. The study also included 74 patients with stable chronic obstructive pulmonary disease. We evaluated the mean respiratory impedance (Zm) as well as values for the inspiration (Zi) and expiration cycles (Ze) at the beginning of inspiration (Zbi) and expiration (Zbe), respectively. The peak-to-peak impedance (Zpp=Zbe-Zbi) and the respiratory cycle dependence (ΔZrs=Ze-Zi) were also analyzed. The diagnostic utility was evaluated by investigating the sensitivity, the specificity and the area under the receiver operating characteristic curve. ClinicalTrials.gov: NCT01888705. Airway obstruction increased the within-breath respiratory impedance parameters that were significantly correlated with the spirometric indices of airway obstruction (R=-0.65, pdisease patients presented significant expiratory-inspiratory differences (p90%). We conclude the following: (1) chronic obstructive pulmonary disease introduces higher respiratory cycle dependence, (2) this increase is proportional to airway obstruction, and (3) the within-breath forced oscillation technique may provide novel parameters that facilitate the diagnosis of respiratory abnormalities in chronic obstructive pulmonary disease.

  8. Within-breath respiratory impedance and airway obstruction in patients with chronic obstructive pulmonary disease

    Directory of Open Access Journals (Sweden)

    Karla Kristine Dames da Silva

    2015-07-01

    Full Text Available OBJECTIVE: Recent work has suggested that within-breath respiratory impedance measurements performed using the forced oscillation technique may help to noninvasively evaluate respiratory mechanics. We investigated the influence of airway obstruction on the within-breath forced oscillation technique in smokers and chronic obstructive pulmonary disease patients and evaluated the contribution of this analysis to the diagnosis of chronic obstructive pulmonary disease. METHODS: Twenty healthy individuals and 20 smokers were assessed. The study also included 74 patients with stable chronic obstructive pulmonary disease. We evaluated the mean respiratory impedance (Zm as well as values for the inspiration (Zi and expiration cycles (Ze at the beginning of inspiration (Zbi and expiration (Zbe, respectively. The peak-to-peak impedance (Zpp=Zbe-Zbi and the respiratory cycle dependence (ΔZrs=Ze-Zi were also analyzed. The diagnostic utility was evaluated by investigating the sensitivity, the specificity and the area under the receiver operating characteristic curve. ClinicalTrials.gov: NCT01888705. RESULTS: Airway obstruction increased the within-breath respiratory impedance parameters that were significantly correlated with the spirometric indices of airway obstruction (R=−0.65, p90%. CONCLUSIONS: We conclude the following: (1 chronic obstructive pulmonary disease introduces higher respiratory cycle dependence, (2 this increase is proportional to airway obstruction, and (3 the within-breath forced oscillation technique may provide novel parameters that facilitate the diagnosis of respiratory abnormalities in chronic obstructive pulmonary disease.

  9. Risk assessment of sleeping disorder breathing based on upper airway centerline evaluation

    Science.gov (United States)

    Alsufyani, Noura; Shen, Rui; Cheng, Irene; Major, Paul

    2013-02-01

    One of the most important breathing disorders in childhood is obstructive sleep apnea syndrome which affects 2-3% of children, and the reported failure rate of surgical treatment was as high as 54%. A possible reason in respiratory complications is having reduced dimensions of the upper airway which are further compressed when muscle tone is decreased during sleep. In this study, we use Cone-beam computed tomography (CBCT) to assess the location or cause of the airway obstruction. To date, all studies analyzing the upper airway in subjects with Sleeping Disorder Breathing were based on linear, area, or volumetric measurements, which are global computations and can easily ignore local significance. Skeletonization was initially introduced as a 3D modeling technique by which representative medial points of a model are extracted to generate centerlines for evaluations. Although centerlines have been commonly used in guiding surgical procedures, our novelty lies in comparing its geometric properties before and after surgeries. We apply 3D data refinement, registration and projection steps to quantify and localize the geometric deviation in target airway regions. Through cross validation with corresponding subjects' therapy data, we expect to quantify the tolerance threshold beyond which reduced dimensions of the upper airway are not clinically significant. The ultimate goal is to utilize this threshold to identify patients at risk of complications. Outcome from this research will also help establish a predictive model for training and to estimate treatment success based on airway measurements prior to intervention. Preliminary results demonstrate the feasibility of our approach.

  10. Continuous positive airway pressure therapy: new generations.

    LENUS (Irish Health Repository)

    Garvey, John F

    2010-02-01

    Continuous positive airway pressure (CPAP) is the treatment of choice for obstructive sleep apnoea syndrome (OSAS). However, CPAP is not tolerated by all patients with OSAS and alternative modes of pressure delivery have been developed to overcome pressure intolerance, thereby improving patient comfort and adherence. Auto-adjustable positive airway pressure (APAP) devices may be utilised for the long-term management of OSAS and may also assist in the initial diagnosis of OSAS and titration of conventional CPAP therapy. Newer modalities such as C-Flex and A-Flex also show promise as treatment options in the future. However, the evidence supporting the use of these alternative modalities remains scant, in particular with regard to long-term cardiovascular outcomes. In addition, not all APAP devices use the same technological algorithms and data supporting individual APAP devices cannot be extrapolated to support all. Further studies are required to validate the roles of APAP, C-Flex and A-Flex. In the interim, standard CPAP therapy should continue as the mainstay of OSAS management.

  11. Continuous positive airway pressure therapy: new generations.

    LENUS (Irish Health Repository)

    Garvey, John F

    2012-02-01

    Continuous positive airway pressure (CPAP) is the treatment of choice for obstructive sleep apnoea syndrome (OSAS). However, CPAP is not tolerated by all patients with OSAS and alternative modes of pressure delivery have been developed to overcome pressure intolerance, thereby improving patient comfort and adherence. Auto-adjustable positive airway pressure (APAP) devices may be utilised for the long-term management of OSAS and may also assist in the initial diagnosis of OSAS and titration of conventional CPAP therapy. Newer modalities such as C-Flex and A-Flex also show promise as treatment options in the future. However, the evidence supporting the use of these alternative modalities remains scant, in particular with regard to long-term cardiovascular outcomes. In addition, not all APAP devices use the same technological algorithms and data supporting individual APAP devices cannot be extrapolated to support all. Further studies are required to validate the roles of APAP, C-Flex and A-Flex. In the interim, standard CPAP therapy should continue as the mainstay of OSAS management.

  12. Aerosol delivery and humidification with the Boussignac continuous positive airway pressure device.

    Science.gov (United States)

    Thille, Arnaud W; Bertholon, Jean-François; Becquemin, Marie-Hélène; Roy, Monique; Lyazidi, Aissam; Lellouche, François; Pertusini, Esther; Boussignac, Georges; Maître, Bernard; Brochard, Laurent

    2011-10-01

    A simple method for effective bronchodilator aerosol delivery while administering continuing continuous positive airway pressure (CPAP) would be useful in patients with severe bronchial obstruction. To assess the effectiveness of bronchodilator aerosol delivery during CPAP generated by the Boussignac CPAP system and its optimal humidification system. First we assessed the relationship between flow and pressure generated in the mask with the Boussignac CPAP system. Next we measured the inspired-gas humidity during CPAP, with several humidification strategies, in 9 healthy volunteers. We then measured the bronchodilator aerosol particle size during CPAP, with and without heat-and-moisture exchanger, in a bench study. Finally, in 7 patients with acute respiratory failure and airway obstruction, we measured work of breathing and gas exchange after a β(2)-agonist bronchodilator aerosol (terbutaline) delivered during CPAP or via standard nebulization. Optimal humidity was obtained only with the heat-and-moisture exchanger or heated humidifier. The heat-and-moisture exchanger had no influence on bronchodilator aerosol particle size. Work of breathing decreased similarly after bronchodilator via either standard nebulization or CPAP, but P(aO(2)) increased significantly only after CPAP aerosol delivery. CPAP bronchodilator delivery decreases the work of breathing as effectively as does standard nebulization, but produces a greater oxygenation improvement in patients with airway obstruction. To optimize airway humidification, a heat-and-moisture exchanger could be used with the Boussignac CPAP system, without modifying aerosol delivery.

  13. Upper airway resistance syndrome. Central electroencephalographic power and changes in breathing effort.

    Science.gov (United States)

    Black, J E; Guilleminault, C; Colrain, I M; Carrillo, O

    2000-08-01

    Upper airway resistance syndrome (UARS) is defined by excessive daytime sleepiness and tiredness, and is associated with increased breathing effort. Its polygraphic features involve progressive increases in esophageal pressure (Pes), terminated by arousal (AR) as defined by the American Sleep Disorders Association (ASDA). With the arousal there is an abrupt decrease in Pes, called Pes reversal. However, Pes reversal can be seen without the presence of an AR. We performed spectral analysis on electroencephalographic data from a central lead for both AR and nonarousal (N-AR) events obtained from 15 UARS patients (eight men and seven women). Delta band activity was increased before and surrounding Pes reversal regardless of the presence or absence of AR. In the period after Pes reversal, alpha, sigma, and beta activity showed a greater increase in AR events than in N-AR events. The Pes measures were identical leading up to the point of reversal, but showed a longer-lasting and significantly greater decrease in respiratory effort after an AR. The data indicate that substantial electroencephalographic changes can be identified in association with Pes events, even when ARs cannot be detected according to standard criteria; however, visually identifiable electroencephalographic arousals clearly have a greater impact on ongoing inspiratory effort.

  14. 21 CFR 868.1780 - Inspiratory airway pressure meter.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Inspiratory airway pressure meter. 868.1780 Section 868.1780 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... meter. (a) Identification. An inspiratory airway pressure meter is a device used to measure the amount...

  15. The 30-year evolution of airway pressure release ventilation (APRV).

    Science.gov (United States)

    Jain, Sumeet V; Kollisch-Singule, Michaela; Sadowitz, Benjamin; Dombert, Luke; Satalin, Josh; Andrews, Penny; Gatto, Louis A; Nieman, Gary F; Habashi, Nader M

    2016-12-01

    Airway pressure release ventilation (APRV) was first described in 1987 and defined as continuous positive airway pressure (CPAP) with a brief release while allowing the patient to spontaneously breathe throughout the respiratory cycle. The current understanding of the optimal strategy to minimize ventilator-induced lung injury is to "open the lung and keep it open". APRV should be ideal for this strategy with the prolonged CPAP duration recruiting the lung and the minimal release duration preventing lung collapse. However, APRV is inconsistently defined with significant variation in the settings used in experimental studies and in clinical practice. The goal of this review was to analyze the published literature and determine APRV efficacy as a lung-protective strategy. We reviewed all original articles in which the authors stated that APRV was used. The primary analysis was to correlate APRV settings with physiologic and clinical outcomes. Results showed that there was tremendous variation in settings that were all defined as APRV, particularly CPAP and release phase duration and the parameters used to guide these settings. Thus, it was impossible to assess efficacy of a single strategy since almost none of the APRV settings were identical. Therefore, we divided all APRV studies divided into two basic categories: (1) fixed-setting APRV (F-APRV) in which the release phase is set and left constant; and (2) personalized-APRV (P-APRV) in which the release phase is set based on changes in lung mechanics using the slope of the expiratory flow curve. Results showed that in no study was there a statistically significant worse outcome with APRV, regardless of the settings (F-ARPV or P-APRV). Multiple studies demonstrated that P-APRV stabilizes alveoli and reduces the incidence of acute respiratory distress syndrome (ARDS) in clinically relevant animal models and in trauma patients. In conclusion, over the 30 years since the mode's inception there have been no strict

  16. Noninvasive Positive Pressure Ventilation or Conventional Mechanical Ventilation for Neonatal Continuous Positive Airway Pressure Failure

    Directory of Open Access Journals (Sweden)

    Zohreh Badiee

    2014-01-01

    Full Text Available Background: The aim of this study was to assess the success rate of nasal intermittent positive pressure ventilation (NIPPV for treatment of continuous positive airway pressure (CPAP failure and prevention of conventional ventilation (CV in preterm neonates. Methods: Since November 2012 to April 2013, a total number of 55 consecutive newborns with gestational ages of 26-35 weeks who had CPAP failure were randomly assigned to one of the two groups. The NIPPV group received NIPPV with the initial peak inspiratory pressure (PIP of 16-20 cmH 2 O and frequency of 40-60 breaths/min. The CV group received PIP of 12-20 cmH 2 O and frequency of 40-60 breaths/min. Results: About 74% of newborns who received NIPPV for management of CPAP failure responded to NIPPV and did not need intubation and mechanical ventilation. Newborns with lower postnatal age at entry to the study and lower 5 min Apgar score more likely had NIPPV failure. In addition, treatment failure was higher in newborns who needed more frequent doses of surfactant. Duration of oxygen therapy was 9.28 days in CV group and 7.77 days in NIPPV group (P = 0.050. Length of hospital stay in CV group and NIPPV groups were 48.7 and 41.7 days, respectively (P = 0.097. Conclusions: NIPPV could decrease the need for intubation and mechanical ventilation in preterm infants with CPAP failure.

  17. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Active Cycle of Breathing Technique Airway Clearance Techniques Autogenic Drainage Basics of Lung Care Chest Physical Therapy ... clearance. Facebook Twitter Email More Related Content Medications Autogenic Drainage Positive Expiratory Pressure High-Frequency Chest Wall ...

  18. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Cycle of Breathing Technique Airway Clearance Techniques Autogenic Drainage Basics of Lung Care Chest Physical Therapy Coughing ... Facebook Twitter Email More Related Content Medications Autogenic Drainage Positive Expiratory Pressure High-Frequency Chest Wall Oscillation ( ...

  19. Chest physiotherapy with positive expiratory pressure breathing after abdominal and thoracic surgery: a systematic review.

    Science.gov (United States)

    Orman, J; Westerdahl, E

    2010-03-01

    A variety of chest physiotherapy techniques are used following abdominal and thoracic surgery to prevent or reduce post-operative complications. Breathing techniques with a positive expiratory pressure (PEP) are used to increase airway pressure and improve pulmonary function. No systematic review of the effects of PEP in surgery patients has been performed previously. The purpose of this systematic review was to determine the effect of PEP breathing after an open upper abdominal or thoracic surgery. A literature search of randomised-controlled trials (RCT) was performed in five databases. The trials included were systematically reviewed by two independent observers and critically assessed for methodological quality. We selected six RCT evaluating the PEP technique performed with a mechanical device in spontaneously breathing adult patients after abdominal or thoracic surgery via thoracotomy. The methodological quality score varied between 4 and 6 on the Physiotherapy Evidence Database score. The studies were published between 1979 and 1993. Only one of the included trials showed any positive effects of PEP compared to other breathing techniques. Today, there is scarce scientific evidence that PEP treatment is better than other physiotherapy breathing techniques in patients undergoing abdominal or thoracic surgery. There is a lack of studies investigating the effect of PEP over placebo or no physiotherapy treatment.

  20. Airway pressure release ventilation and biphasic positive airway pressure: a systematic review of definitional criteria.

    Science.gov (United States)

    Rose, Louise; Hawkins, Martyn

    2008-10-01

    The objective of this study was to identify the definitional criteria for the pressure-limited and time-cycled modes: airway pressure release ventilation (APRV) and biphasic positive airway pressure (BIPAP) available in the published literature. Systematic review. Medline, PubMed, Cochrane, and CINAHL databases (1982-2006) were searched using the following terms: APRV, BIPAP, Bilevel and lung protective strategy, individually and in combination. Two independent reviewers determined the paper eligibility and abstracted data from 50 studies and 18 discussion articles. Of the 50 studies, 39 (78%) described APRV, and 11 (22%) described BIPAP. Various study designs, populations, or outcome measures were investigated. Compared to BIPAP, APRV was described more frequently as extreme inverse inspiratory:expiratory ratio [18/39 (46%) vs. 0/11 (0%), P = 0.004] and used rarely as a noninverse ratio [2/39 (5%) vs. 3/11 (27%), P = 0.06]. One (9%) BIPAP and eight (21%) APRV studies used mild inverse ratio (>1:1 to branding may further add to confusion. Generic naming of modes and consistent definitional parameters may improve consistency of patient response for a given mode and assist with clinical implementation.

  1. Exploring Airway Diseases by NMR-Based Metabonomics: A Review of Application to Exhaled Breath Condensate

    Directory of Open Access Journals (Sweden)

    Matteo Sofia

    2011-01-01

    Full Text Available There is increasing evidence that biomarkers of exhaled gases or exhaled breath condensate (EBC may help in detecting abnormalities in respiratory diseases mirroring increased, oxidative stress, airways inflammation and endothelial dysfunction. Beside the traditional techniques to investigate biomarker profiles, “omics” sciences have raised interest in the clinical field as potentially improving disease phenotyping. In particular, metabonomics appears to be an important tool to gain qualitative and quantitative information on low-molecular weight metabolites present in cells, tissues, and fluids. Here, we review the potential use of EBC as a suitable matrix for metabonomic studies using nuclear magnetic resonance (NMR spectroscopy. By using this approach in airway diseases, it is now possible to separate specific EBC profiles, with implication in disease phenotyping and personalized therapy.

  2. Treatment response of airway clearance assessed by single-breath washout in children with cystic fibrosis.

    Science.gov (United States)

    Abbas, Chiara; Singer, Florian; Yammine, Sophie; Casaulta, Carmen; Latzin, Philipp

    2013-12-01

    We studied the ability of 4 single-breath gas washout (SBW) tests to measure immediate effects of airway clearance in children with CF. 25 children aged 4-16 years with CF performed pulmonary function tests to assess short-term variability at baseline and response to routine airway clearance. Tidal helium and sulfur hexafluoride (double-tracer gas: DTG) SBW, tidal capnography, tidal and vital capacity nitrogen (N2) SBW and spirometry were applied. We analyzed the gasses' phase III slope (SnIII--normalized for tidal volume) and FEV1 from spirometry. SnIII from tidal DTG-SBW, SnIII from vital capacity N2-SBW, and FEV1 improved significantly after airway clearance. From these tests, individual change of SnIII from tidal DTG-SBW and FEV1 exceeded short-term variability in 10 and 6 children. With the tidal DTG-SBW, an easy and promising test for peripheral gas mixing efficiency, immediate pulmonary function response to airway clearance can be assessed in CF children. Copyright © 2013 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  3. Efficacy of the addition of positive airway pressure to conventional chest physiotherapy in resolution of pleural effusion after drainage: protocol for a randomised controlled trial

    Directory of Open Access Journals (Sweden)

    Elinaldo da Conceição dos Santos

    2015-04-01

    Discussion: Conventional chest physiotherapy and intermittent positive airway pressure breathing are widely indicated for people with pleural effusion and chest drains; however, no studies have evaluated the real benefit of this type of treatment. Our hypothesis is that optimised lung expansion achieved through the application of intermittent positive airway pressure will accelerate the reabsorption of pleural effusion, decrease the duration of chest drainage and respiratory system impairment, reduce the length of hospital stay, and reduce the incidence of pulmonary complications.

  4. Sibutramine versus continuous positive airway pressure in obese obstructive sleep apnoea patients.

    Science.gov (United States)

    Ferland, A; Poirier, P; Sériès, F

    2009-09-01

    The aim of the present study was to compare the efficacy of 1 yr of sibutramine-induced weight loss versus continuous positive airway pressure (CPAP) treatment on sleep-disordered breathing, cardiac autonomic function and systemic blood pressure in obese patients with obstructive sleep apnoea. Subjects with a body mass index of > or =30 kg.m(-2) without previous treatment for obstructive sleep apnoea underwent either sibutramine (n = 22) or CPAP (n = 18) treatment for 1 yr. Sibutramine induced a 5.4+/-1.4 kg decrease in body weight compared to the CPAP group, in which no changes in anthropometric variables were observed. The CPAP treatment improved all sleep and respiratory variables, whereas sibutramine-induced weight loss improved only nocturnal arterial oxygen saturation profile. Only CPAP treatment improved night-time systolic and diastolic blood pressure and 24-h and daytime ambulatory diastolic blood pressure. Sibutramine-induced weight loss had no impact on indices of heart rate variability, whereas CPAP treatment increased daytime time domain indices. CPAP treatment for 1 yr had beneficial impacts on nocturnal breathing disturbances, and improved nocturnal oxygenation, night-time systolic and diastolic blood pressure, and daytime cardiac parasympathetic modulation. Sibutramine did not improve sleep-disordered breathing, systemic blood pressure or heart rate variability. There were no adverse effects, such as increment in blood pressure or arrhythmias, associated with this treatment regimen.

  5. Short-term effects of positive expiratory airway pressure in patients being weaned from mechanical ventilation

    Directory of Open Access Journals (Sweden)

    Marcelo de Mello Rieder

    2009-05-01

    Full Text Available OBJECTIVE: To investigate the feasibility and the cardiorespiratory effects of using positive expiratory airway pressure, a physiotherapeutic tool, in comparison with a T-tube, to wean patients from mechanical ventilation. METHODS/DESIGN: A prospective, randomized, cross-over study. SETTING: Two intensive care units. PATIENTS AND INTERVENTIONS: We evaluated forty patients who met weaning criteria and had been mechanically-ventilated for more than 48 hours, mean age 59 years, including 23 males. All patients were submitted to the T-tube and Expiratory Positive Airway Pressure devices, at 7 cm H2O, during a 30-minute period. Cardiorespiratory variables including work of breathing, respiratory rate (rr, peripheral oxygen saturation (SpO2, heart rate (hr, systolic, diastolic and mean arterial pressures (SAP, DAP, MAP were measured in the first and thirtieth minutes. The condition was analyzed as an entire sample set (n=40 and was also divided into subconditions: chronic obstructive pulmonary disease (n=14 and non-chronic obstructive pulmonary disease (non- chronic obstructive pulmonary disease (n=26 categories. Comparisons were made using a t-test and Analysis of Variance. The level of significance was p < 0.05. RESULTS: Our data showed an increase in work of breathing in the first and thirtieth minutes in the EPAP condition (0.86+ 0.43 and 1.02+1.3 as compared with the T-tube condition (0.25+0.26 and 0.26+0.35 (p<0.05, verified by the flow-sensor monitor (values in J/L. No statistical differences were observed when comparing the Expiratory Positive Airway Pressure and T-tube conditions with regard to cardiorespiratory measurements. The same result was observed for both chronic obstructive pulmonary disease and non- chronic obstructive pulmonary disease subconditions. CONCLUSIONS: Our study demonstrated that, in weaning patients from mechanical ventilation, the use of a fixed level of Expiratory Positive Airway Pressure caused an increase in work of

  6. Exhaled breath condensate cysteinyl leukotrienes and airway remodeling in childhood asthma: a pilot study

    Directory of Open Access Journals (Sweden)

    Kharitonov Sergei A

    2006-04-01

    Full Text Available Abstract Background It has been suggested that cysteinyl leukotrienes (cysLTs play an important role in airway remodeling. Previous reports have indicated that cysLTs augment human airway smooth muscle cell proliferation. Recently, cysLTs have been measured in exhaled breath condensate (EBC. The aim of this study was to evaluate the relationship between cysLTs in EBC and another marker of airway remodeling, reticular basement membrane (RBM thickening, in endobronchial biopsies in children. Methods 29 children, aged 4–15 years, with moderate to severe persistent asthma, who underwent bronchoscopy as part of their clinical assessment, were included. Subjects underwent spirometry and EBC collection for cysLTs analysis, followed by bronchoscopy and endobronchial biopsy within 24 hours. Results EBC cysLTs were significantly lower in asthmatic children who were treated with montelukast than in those who were not (median (interquartile range 36.62 (22.60–101.05 versus 249.1 (74.21–526.36 pg/ml, p = 0.004. There was a significant relationship between EBC cysLTs and RBM thickness in the subgroup of children who were not treated with montelukast (n = 13, r = 0.75, p = 0.003. Conclusion EBC cysLTs appear to be associated with RBM thickening in asthma.

  7. A Comparative Study of Cuffed Pharyngeal Tube (CPR with Endotracheal Tube in Airway Management and Ventilation of Spontaneously Breathing Patients Undergoing General Anesthesia

    Directory of Open Access Journals (Sweden)

    F Mir Mohammad Sadeghi

    2002-09-01

    Full Text Available Background: Cuffed pharyngeal tube is a device designed for ventilation of anesthetized patients. CPT has advantages over face mask including: maintaining of face mask can be difficult and boring after several minutes and mobility of the practitioner is reduced due to involvement of hands. Mask pressure can cause soft tissue and nerve damage around the nose. Anesthetic gas leakage from the mask adds to the operation room pollution. In difficult intubation CPT can be life-saving. Materials and Methods: In our study CPT was compared with endotracheal tube (ET in anesthetized patients. A scoring system for evaluating ventilation of patients was designed using symmetric chest wall motion during ventilation with anesthesia bag and sensing lung compliance through it, auscultation of breathing sounds, oscilation of bag with breathing and peripheral oxygen saturation by pulse oxymetry. Respiratory complications (pulmonary aspiration, Iaryngospasm and bronchospasm, nausea and vomiting were looked for during anesthesia. Results: The results showed that CPT was successful as ET in ventilation of spontaneously breathing patients and incidence of respiratory complications with CPT was no more than ET. Airway resistance was significantly greater with CPT than ET (P<0.05. Patients with ET had significantly greater incidence of sore throat than with CPT (P<0.05. Conclusion: Thus we concluded that CPT can be used for ventilation of anesthetized patients not predisposed to pulmonary aspiration and whose peak airway pressure does not exceed 20-25 CmH2O.

  8. Synchronized imaging and acoustic analysis of the upper airway in patients with sleep-disordered breathing

    International Nuclear Information System (INIS)

    Chang, Yi-Chung; Pham, Van-Truong; Wang, Yung-Hung; Lin, Chen; Lo, Men-Tzung; Huon, Leh-Kiong; Wang, Pa-Chun; Chen, Yunn-Jy; Jiang, Sun-Fen; Shih, Tiffany Ting-Fang; Tran, Thi-Thao; Tsao, Jenho

    2014-01-01

    Progressive narrowing of the upper airway increases airflow resistance and can produce snoring sounds and apnea/hypopnea events associated with sleep-disordered breathing due to airway collapse. Recent studies have shown that acoustic properties during snoring can be altered with anatomic changes at the site of obstruction. To evaluate the instantaneous association between acoustic features of snoring and the anatomic sites of obstruction, a novel method was developed and applied in nine patients to extract the snoring sounds during sleep while performing dynamic magnetic resonance imaging (MRI). The degree of airway narrowing during the snoring events was then quantified by the collapse index (ratio of airway diameter preceding and during the events) and correlated with the synchronized acoustic features. A total of 201 snoring events (102 pure retropalatal and 99 combined retropalatal and retroglossal events) were recorded, and the collapse index as well as the soft tissue vibration time were significantly different between pure retropalatal (collapse index, 24  ±  11%; vibration time, 0.2  ±  0.3 s) and combined (retropalatal and retroglossal) snores (collapse index, 13  ±  7% [P ≤ 0.0001]; vibration time, 1.2  ±  0.7 s [P ≤ 0.0001]). The synchronized dynamic MRI and acoustic recordings successfully characterized the sites of obstruction and established the dynamic relationship between the anatomic site of obstruction and snoring acoustics. (paper)

  9. Use of tidal breathing curves for evaluating expiratory airway obstruction in infants.

    Science.gov (United States)

    Hevroni, Avigdor; Goldman, Aliza; Blank-Brachfeld, Miriam; Abu Ahmad, Wiessam; Ben-Dov, Lior; Springer, Chaim

    2018-01-15

    To evaluate tidal breathing (TB) flow-volume and flow-time curves for identification of expiratory airway obstruction in infants. Pulmonary function tests were analyzed retrospectively in 156 infants aged 3-24 months with persistent or recurrent respiratory complaints. Parameters derived from TB curves were compared to maximal expiratory flow at functional residual capacity ([Formula: see text]maxFRC) measured by rapid thoracoabdominal compression technique. Analyzed parameters were: inspiratory time (t I ), expiratory time (t E ), tidal volume, peak tidal expiratory flow (PTEF), time to peak tidal expiratory flow (t PTEF ), expiratory flow when 50% and 25% of tidal volume remains in the lungs (FEF 50 , FEF 25 , respectively), and the ratios t PTEF /t E , t I /t E , FEF 50 /PTEF, and FEF 25 /PTEF. Statistical comparisons between flow indices and TB parameters were performed using mean squared error and Pearson's sample correlation coefficient. The study population was also divided into two groups based on severity of expiratory obstruction (above or below z-score for [Formula: see text]maxFRC of -2) to generate receiver operating characteristic (ROC) curves and calculate discriminatory values between the groups. TB parameters that were best correlated to [Formula: see text]maxFRC were: t PTEF /t E , FEF 50 /PTEF, and FEF 25 /PTEF, with r = 0.61, 0.67, 0.65, respectively (p < 0.0001 for all). ROC curves for FEF 50 /PTEF, FEF 25 /PTEF and t PTEF /t E showed areas under the curve of 0.813, 0.797, and 0.796, respectively. Cutoff value z-scores of -0.35, -0.34, and -0.43 for these three parameters, respectively, showed an 86% negative predictive value for severe airway obstructions. TB curves can assist in ruling out severe expiratory airway obstruction in infants.

  10. Boussignac continuous positive airway pressure for weaning with tracheostomy tubes

    NARCIS (Netherlands)

    Dieperink, Willem; Aarts, Leon P. H. J.; Rodgers, Michael G. G.; Delwig, Hans; Nijsten, Maarten W. N.

    2008-01-01

    Background: In patients who are weaned with a tracheostomy tube ( TT), continuous positive airway pressure ( CPAP) is frequently used. Dedicated CPAP systems or ventilators with bulky tubing are usually applied. However, CPAP can also be effective without a ventilator by the disposable Bous-signac

  11. Nasal continuous positive airway pressure: does bubbling improve gas exchange?

    Science.gov (United States)

    Morley, C J; Lau, R; De Paoli, A; Davis, P G

    2005-07-01

    In a randomised crossover trial, 26 babies, treated with Hudson prong continuous positive airway pressure (CPAP) from a bubbling bottle, received vigorous, high amplitude, or slow bubbling for 30 minutes. Pulse oximetry, transcutaneous carbon dioxide, and respiratory rate were recorded. The bubbling rates had no effect on carbon dioxide, oxygenation, or respiratory rate.

  12. Multiple applications of the Boussignac continuous positive airway pressure system

    NARCIS (Netherlands)

    Dieperink, Willem

    2008-01-01

    Continuous positive airway pressure, (CPAP) is a form of treatment to support patients with dyspnea. For the application of CPAP a mechanical ventilator or complex CPAP apparatus is mostly used. The Boussignac CPAP (BCPAP) system developed by George Boussignac does not need such apparatus. The BCPAP

  13. Duration of continuous positive airway pressure in premature infants

    Science.gov (United States)

    Bamat, Nicolas; Jensen, Erik A.; Kirpalani, Haresh

    2016-01-01

    SUMMARY Continuous positive airway pressure (CPAP) has been used for respiratory support in premature infants for more than 40 years and is now a cornerstone of modern neonatal care. Clinical research on CPAP has primarily focused on understanding which devices and pressure sources best implement this therapy. In contrast, less research has examined the optimal duration over which CPAP is administered. We review this aspect of CPAP therapy. PMID:26948885

  14. Duration of continuous positive airway pressure in premature infants

    OpenAIRE

    Bamat, Nicolas; Jensen, Erik A.; Kirpalani, Haresh

    2016-01-01

    Continuous positive airway pressure (CPAP) has been used for respiratory support in premature infants for more than 40 years and is now a cornerstone of modern neonatal care. Clinical research on CPAP has primarily focused on understanding which devices and pressure sources best implement this therapy. In contrast, less research has examined the optimal duration over which CPAP is administered. We review this aspect of CPAP therapy.

  15. Unidirectional Expiratory Valve Method to Assess Maximal Inspiratory Pressure in Individuals without Artificial Airway.

    Directory of Open Access Journals (Sweden)

    Samantha Torres Grams

    Full Text Available Maximal Inspiratory Pressure (MIP is considered an effective method to estimate strength of inspiratory muscles, but still leads to false positive diagnosis. Although MIP assessment with unidirectional expiratory valve method has been used in patients undergoing mechanical ventilation, no previous studies investigated the application of this method in subjects without artificial airway.This study aimed to compare the MIP values assessed by standard method (MIPsta and by unidirectional expiratory valve method (MIPuni in subjects with spontaneous breathing without artificial airway. MIPuni reproducibility was also evaluated.This was a crossover design study, and 31 subjects performed MIPsta and MIPuni in a random order. MIPsta measured MIP maintaining negative pressure for at least one second after forceful expiration. MIPuni evaluated MIP using a unidirectional expiratory valve attached to a face mask and was conducted by two evaluators (A and B at two moments (Tests 1 and 2 to determine interobserver and intraobserver reproducibility of MIP values. Intraclass correlation coefficient (ICC[2,1] was used to determine intraobserver and interobserver reproducibility.The mean values for MIPuni were 14.3% higher (-117.3 ± 24.8 cmH2O than the mean values for MIPsta (-102.5 ± 23.9 cmH2O (p<0.001. Interobserver reproducibility assessment showed very high correlation for Test 1 (ICC[2,1] = 0.91, and high correlation for Test 2 (ICC[2,1] = 0.88. The assessment of the intraobserver reproducibility showed high correlation for evaluator A (ICC[2,1] = 0.86 and evaluator B (ICC[2,1] = 0.77.MIPuni presented higher values when compared with MIPsta and proved to be reproducible in subjects with spontaneous breathing without artificial airway.

  16. Improved fireman's compressed air breathing system pressure vessel development program

    Science.gov (United States)

    King, H. A.; Morris, E. E.

    1973-01-01

    Prototype high pressure glass filament-wound, aluminum-lined pressurant vessels suitable for use in a fireman's compressed air breathing system were designed, fabricated, and acceptance tested in order to demonstrate the feasibility of producing such high performance, lightweight units. The 4000 psi tanks have a 60 standard cubic foot (SCF) air capacity, and have a 6.5 inch diamter, 19 inch length, 415 inch volume, weigh 13 pounds when empty, and contain 33 percent more air than the current 45 SCF (2250 psi) steel units. The current steel 60 SCF (3000 psi) tanks weigh approximately twice as much as the prototype when empty, and are 2 inches, or 10 percent shorter. The prototype units also have non-rusting aluminum interiors, which removes the hazard of corrosion, the need for internal coatings, and the possibility of rust particles clogging the breathing system.

  17. The New Perilaryngeal Airway (CobraPLA™)1 Is as Efficient as the Laryngeal Mask Airway (LMA™)2, But Provides Better Airway Sealing Pressures

    Science.gov (United States)

    Akça, Ozan; Wadhwa, Anupama; Sengupta, Papiya; Durrani, Jaleel; Hanni, Keith; Wenke, Mary; Yücel, Yüksel; Lenhardt, Rainer; Doufas, Anthony G.; Sessler, Daniel I.

    2006-01-01

    The Laryngeal Mask Airway (LMA) is a frequently-used efficient airway device, yet it sometimes seals poorly, thus reducing the efficacy of positive-pressure ventilation. The Perilaryngeal Airway (CobraPLA) is a novel airway device with a larger pharyngeal cuff (when inflated). We tested the hypothesis that the CobraPLA was superior to LMA with regard to insertion time and airway sealing pressure and comparable to LMA in airway adequacy and recovery characteristics. After midazolam and fentanyl, 81 ASA I-II outpatients having elective surgery were randomized to receive an LMA or CobraPLA. Anesthesia was induced with propofol (2.5 mg/kg, IV), and the airway inserted. We measured 1) insertion time; 2) adequacy of the airway (no leak at 15-cm-H2O peak pressure or tidal volume of 5 ml/kg); 3) airway sealing pressure; 4) number of repositioning attempts; and 5) sealing quality (no leak at tidal volume of 8 ml/kg). At the end of surgery, gastric insufflation, postoperative sore throat, dysphonia, and dysphagia were evaluated. Data were compared with unpaired t-tests, chi-square tests, or Fisher’s Exact tests; P<0.05 was significant. Patient characteristics, insertion times, airway adequacy, number of repositioning attempts, and recovery were similar in each group. Airway sealing pressure was significantly greater with CobraPLA (23±6 cm H2O) than LMA (18±5 cm H2O, P<0.001). The CobraPLA has insertion characteristics similar to LMA, but better airway sealing capabilities. PMID:15281543

  18. Sleep apnea is associated with bronchial inflammation and continuous positive airway pressure-induced airway hyperresponsiveness.

    Science.gov (United States)

    Devouassoux, Gilles; Lévy, Patrick; Rossini, Eliane; Pin, Isabelle; Fior-Gozlan, Michèle; Henry, Mireille; Seigneurin, Daniel; Pépin, Jean-Louis

    2007-03-01

    Obstructive sleep apnea syndrome (OSA) is associated with systemic and upper airway inflammation. Pharyngeal inflammation has a potential role in upper airway collapse, whereas systemic inflammation relates to cardiovascular morbidity. However, the presence of an inflammatory involvement of lower airway has been poorly investigated. The aim of the study was to demonstrate an inflammatory process at the bronchial level in patients with OSA and to analyze effects of continuous positive airway pressure (CPAP) application and humidification on bronchial mucosa. The study was conducted by using sequential induced sputum for cell analysis and IL-8 production, nitric oxide exhalation measurement, and methacholine challenge before and after CPAP. Bronchial neutrophilia and a high IL-8 concentration were observed in untreated OSA compared with controls (75% +/- 20% vs 43% +/- 12%, P Obstructive sleep apnea syndrome is associated with bronchial inflammation. Our data demonstrate CPAP effect on the development of AHR, possibly facilitated by the pre-existing inflammation. Both issues should be evaluated during long-term CPAP use. Results showing a spontaneous bronchial inflammation in OSA and the development of a CPAP-related AHR require a long-term follow-up to evaluate consequences on chronic bronchial obstruction.

  19. Firefighter's compressed air breathing system pressure vessel development program

    Science.gov (United States)

    Beck, E. J.

    1974-01-01

    The research to design, fabricate, test, and deliver a pressure vessel for the main component in an improved high-performance firefighter's breathing system is reported. The principal physical and performance characteristics of the vessel which were required are: (1) maximum weight of 9.0 lb; (2) maximum operating pressure of 4500 psig (charge pressure of 4000 psig); (3) minimum contained volume of 280 in. 3; (4) proof pressure of 6750 psig; (5) minimum burst pressure of 9000 psig following operational and service life; and (6) a minimum service life of 15 years. The vessel developed to fulfill the requirements described was completely sucessful, i.e., every category of performence was satisfied. The average weight of the vessel was found to be about 8.3 lb, well below the 9.0 lb specification requirement.

  20. Social Stress Induced Pressure Breathing and Consequent Blood Pressure Oscillation

    NARCIS (Netherlands)

    Fokkema, Dirk S.; Koolhaas, Jaap M.; Meulen, Jan van der; Schoemaker, Regien

    1986-01-01

    A large amplitude blood pressure oscillation occurs during social defeat in a territorial fight between male rats, and during the application of a psychosocial stimulus associated with this defeat. Synchronous recording of blood pressure, intrathoracic pressure and diaphragm activity shows that the

  1. Impact of microarousal associated with increased negative esophageal pressure in sleep-disordered breathing.

    Science.gov (United States)

    Sukegawa, Mayo; Noda, Akiko; Yasuda, Yoshinari; Nakata, Seiichi; Sugiura, Tatsuki; Miyata, Seiko; Honda, Kumiko; Hasegawa, Yoshinori; Nakashima, Tsutomu; Koike, Yasuo

    2009-11-01

    "Microarousals" during sleep have not been analyzed systematically. We investigated the importance of "microarousals" (lasting 1.5-3 s). Standard polysomnography including esophageal pressure (Pes) assessment was performed on ten patients (aged 54.0 +/- 5.0 years) with respiratory effort-related arousal > or =5/h. We measured the number of arousals per hour (American Sleep Disorders Association (ASDA) arousal index) and the number of microarousals lasting 1.5-3 s per hour (mASDA arousal index). On the night after the baseline sleep study, we performed overnight continuous positive airway pressure (CPAP) titration. mASDA arousals, characterized by lower Pes values, were observed more frequently in patients with sleep-disordered breathing. The Pes results did not differ significantly between ASDA and mASDA arousals (-15.6 +/- -5.0 vs -15.0 +/- -4.4 cmH(2)O). mASDA arousals were significantly improved by CPAP treatment (mASDA arousals, 82.6 +/- 60.1 vs 6.0 +/- 1.4/h). mASDA arousals were characterized by an increase in Pes. mASDA arousals are thus key to our understanding of clinical manifestations in patients with sleep-disordered breathing.

  2. Comparison of Efficacy and Tolerance of Automatic Continuous Positive Airway Pressure Devices With the Optimum Continuous Positive Airway Pressure.

    Science.gov (United States)

    Tommi, George; Aronow, Wilbert S; Sheehan, John C; McCleay, Matthew T; Meyers, Patrick G

    Patients diagnosed with obstructive sleep apnea syndrome were randomly placed on automatic continuous positive airway pressure (ACPAP) for 2 hours followed by manual titration for the rest of the night. One hundred sixty-one patients entered the study, with at least 50 patients titrated with each of 3 ACPAP devices. The optimum continuous positive airway pressure (CPAP) was defined as the lowest pressure with an apnea-hypoxia index of ≤5/hr, which ranged from 4 cm to 18 cm. Success with ACPAP was approximately 60%-80% when the optimum CPAP was 4-6 cm but fell to below 30% if the optimum CPAP was ≥8 cm (P = 0.001). Average ACPAP ranged from 2 to 10 cm below the optimum level if the optimum CPAP was ≥8 cm. Patients who responded to a low CPAP but deteriorated on higher pressures failed to respond to any of the automatic devices. We recommend that CPAP titration be performed manually before initiation of ACPAP in patients with obstructive sleep apnea. The basal pressure for ACPAP should be the optimum pressure obtained by manual titration. Limits on the upper level of ACPAP may be necessary for patients who deteriorate on higher positive pressures.

  3. Continuous positive airway pressure treatment increases bronchial reactivity in obstructive sleep apnea patients.

    Science.gov (United States)

    Korczynski, Piotr; Gorska, Katarzyna; Przybylowski, Tadeusz; Bielicki, Piotr; Zielinski, Jan; Chazan, Ryszarda

    2009-01-01

    The effects of continuous positive airway pressure (CPAP) treatment on the function of the lower airways are poorly understood. One of the methods used to determine the influence of positive pressure breathing on lower airways is the bronchial hyperreactivity test. Some authors report that CPAP increases bronchial hyperreactivity, while others report decreases. To assess the influence of CPAP treatment on bronchial reactivity and the effects of bronchial hyperreactivity on compliance to CPAP treatment. The study group consisted of 101 obstructive sleep apnea syndrome patients (88 men and 13 women) with a mean age of 51 ± 11 years, mean apnea-hypopnea index of 53 ± 20 and mean body mass index of 32.6 ± 5.4. Patients were randomly assigned to a treatment group that received 3 weeks of CPAP therapy (group 1) or to a nontreatment control group (group 2). Pulmonary function tests and the methacholine bronchial provocation test were performed at baseline and 3 weeks later. There were no statistically significant differences between treated and control groups in anthropometry and polysomnography variables. At baseline, bronchial hyperreactivity was found in 6 patients from group 1 and 5 patients from group 2. A significant increase in bronchial reactivity was observed after CPAP treatment. Log PC20M decreased from 1.38 ± 0.30 at baseline to 1.26 ± 0.50 (p bronchial hyperreactivity during CPAP treatment were characterized by significantly lower FEV1, FVC and MEF50 values. CPAP produces statistically significant bronchial hyperreactivity. However, there were no clinical symptoms and it is not necessary to withdraw previous therapies. Copyright © 2009 S. Karger AG, Basel.

  4. Continuous positive airway pressure: Physiology and comparison of devices.

    Science.gov (United States)

    Gupta, Samir; Donn, Steven M

    2016-06-01

    Nasal continuous positive airway pressure (CPAP) is increasingly used for respiratory support in preterm babies at birth and after extubation from mechanical ventilation. Various CPAP devices are available for use that can be broadly grouped into continuous flow and variable flow. There are potential physiologic differences between these CPAP systems and the choice of a CPAP device is too often guided by individual expertise and experience rather than by evidence. When interpreting the evidence clinicians should take into account the pressure generation sources, nasal interface, and the factors affecting the delivery of pressure, such as mouth position and respiratory drive. With increasing use of these devices, better monitoring techniques are required to assess the efficacy and early recognition of babies who are failing and in need of escalated support. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Home continuous positive airway pressure for cardiopulmonary indications in infants and children.

    Science.gov (United States)

    Al-Iede, Montaha; Kumaran, Radhagini; Waters, Karen

    2018-04-30

    A number of reports exist regarding the use of continuous positive airway pressure (CPAP) to manage obstructive sleep apnoea (OSA) in children, which we term 'conventional CPAP'. In contrast, there are few reports of home CPAP use for other indications, which we have grouped under the term 'cardiopulmonary'. The aims of this study were to (1) document cardiopulmonary indications for CPAP use in a cohort of infants and children, and (2) evaluate its effectiveness in this group. Hospital records were reviewed for 645 patients who were commenced on long-term CPAP over a 10-year period at a single-tertiary hospital (Children's Hospital at Westmead). This study evaluated the group where the primary indication for CPAP was not OSA ('cardiopulmonary CPAP'). Data evaluated included: demographics, diagnoses, indications for CPAP, hours of use (compliance) and sleep study results at baseline and on CPAP. Of 645 children, 148 (23%) used home CPAP for cardiopulmonary indications; and 130 (87.8%) of these were included. For this group, mean age at CPAP initiation was 18.6 ± 33.6 months (range one week to 16.8 years). Cardiopulmonary indications for CPAP use included: primary airway diseases 65 (50%), chronic lung diseases 33 (25.4%), congenital heart disease (CHD) 20 (15.4%), and both CHD and airway malacia 12 (9.2%). All sleep study variables improved on CPAP relative to the diagnostic sleep study (p 4 h/night). Interstitial lung diseases and other cardiorespiratory disorders, often of congenital origin, can be effectively treated with home CPAP whether they are associated with OSA or not. Sleep studies demonstrated improved gas exchange, sleep and reduced work of breathing with CPAP use. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Can a central blood volume deficit be detected by systolic pressure variation during spontaneous breathing?

    DEFF Research Database (Denmark)

    Dahl, Michael; Hayes, Chris; Steen Rasmussen, Bodil

    2016-01-01

    BACKGROUND: Whether during spontaneous breathing arterial pressure variations (APV) can detect a volume deficit is not established. We hypothesized that amplification of intra-thoracic pressure oscillations by breathing through resistors would enhance APV to allow identification of a reduced card...

  7. Insomnia complaints in lean patients with obstructive sleep apnea negatively affect positive airway pressure treatment adherence.

    Science.gov (United States)

    Eysteinsdottir, Bjorg; Gislason, Thorarinn; Pack, Allan I; Benediktsdottir, Bryndís; Arnardottir, Erna S; Kuna, Samuel T; Björnsdottir, Erla

    2017-04-01

    The objective of this study was to evaluate the determinants of long-term adherence to positive airway pressure treatment among patients with obstructive sleep apnea, with special emphasis on patients who stop positive airway pressure treatment within 1 year. This is a prospective long-term follow-up of subjects in the Icelandic Sleep Apnea Cohort who were diagnosed with obstructive sleep apnea between 2005 and 2009, and started on positive airway pressure treatment. In October 2014, positive airway pressure adherence was obtained by systematically evaluating available clinical files (n = 796; 644 males, 152 females) with moderate to severe obstructive sleep apnea (apnea-hypopnea index ≥15 events per h). The mean follow-up time was 6.7 ± 1.2 years. In total, 123 subjects (15.5%) returned their positive airway pressure device within the first year, 170 (21.4%) returned it later and 503 (63.2%) were still using positive airway pressure. The quitters within the first year had lower body mass index, milder obstructive sleep apnea, less sleepiness, and more often had symptoms of initial and late insomnia compared with long-term positive airway pressure users at baseline. Both initial and late insomnia were after adjustment still significantly associated with being an early quitter among subjects with body mass index insomnia are associated with early quitting on positive airway pressure among non-obese subjects. © 2016 European Sleep Research Society.

  8. Effect of nasal continuous and biphasic positive airway pressure on lung volume in preterm infants

    NARCIS (Netherlands)

    Miedema, Martijn; van der Burg, Pauline S.; Beuger, Sabine; de Jongh, Frans H.; Frerichs, Inez; van Kaam, Anton H.

    2013-01-01

    To monitor regional changes in end-expiratory lung volume (EELV), tidal volumes, and their ventilation distribution during different levels of nasal continuous positive airway pressure (nCPAP) and nasal biphasic positive airway pressure (BiPAP) in stable preterm infants. By using electrical

  9. Early nasal continuous positive airway pressure in a cohort of the smallest infants in Denmark

    DEFF Research Database (Denmark)

    Hansen, Bo M; Esbjørn, Barbara Hoff; Greisen, G

    2004-01-01

    To evaluate neurodevelopmental outcome at age 5 y of age in a cohort of preterm children treated mainly with nasal continuous positive airway pressure (CPAP) in the neonatal period.......To evaluate neurodevelopmental outcome at age 5 y of age in a cohort of preterm children treated mainly with nasal continuous positive airway pressure (CPAP) in the neonatal period....

  10. Higher levels of spontaneous breathing reduce lung injury in experimental moderate acute respiratory distress syndrome.

    Science.gov (United States)

    Carvalho, Nadja C; Güldner, Andreas; Beda, Alessandro; Rentzsch, Ines; Uhlig, Christopher; Dittrich, Susanne; Spieth, Peter M; Wiedemann, Bärbel; Kasper, Michael; Koch, Thea; Richter, Torsten; Rocco, Patricia R; Pelosi, Paolo; de Abreu, Marcelo Gama

    2014-11-01

    To assess the effects of different levels of spontaneous breathing during biphasic positive airway pressure/airway pressure release ventilation on lung function and injury in an experimental model of moderate acute respiratory distress syndrome. Multiple-arm randomized experimental study. University hospital research facility. Thirty-six juvenile pigs. Pigs were anesthetized, intubated, and mechanically ventilated. Moderate acute respiratory distress syndrome was induced by repetitive saline lung lavage. Biphasic positive airway pressure/airway pressure release ventilation was conducted using the airway pressure release ventilation mode with an inspiratory/expiratory ratio of 1:1. Animals were randomly assigned to one of four levels of spontaneous breath in total minute ventilation (n = 9 per group, 6 hr each): 1) biphasic positive airway pressure/airway pressure release ventilation, 0%; 2) biphasic positive airway pressure/airway pressure release ventilation, > 0-30%; 3) biphasic positive airway pressure/airway pressure release ventilation, > 30-60%, and 4) biphasic positive airway pressure/airway pressure release ventilation, > 60%. The inspiratory effort measured by the esophageal pressure time product increased proportionally to the amount of spontaneous breath and was accompanied by improvements in oxygenation and respiratory system elastance. Compared with biphasic positive airway pressure/airway pressure release ventilation of 0%, biphasic positive airway pressure/airway pressure release ventilation more than 60% resulted in lowest venous admixture, as well as peak and mean airway and transpulmonary pressures, redistributed ventilation to dependent lung regions, reduced the cumulative diffuse alveolar damage score across lungs (median [interquartile range], 11 [3-40] vs 18 [2-69]; p ventilation more than 0-30% and more than 30-60% showed a less consistent pattern of improvement in lung function, inflammation, and damage compared with biphasic positive airway

  11. Imaging of mucus clearance in the airways of living spontaneously breathing mice by optical coherence microscopy (Conference Presentation)

    Science.gov (United States)

    Pieper, Mario; Schulz-Hildebrandt, Hinnerk; Hüttmann, Gereon; König, Peter

    2016-03-01

    Mucus transport is essential to remove inhaled particles and pathogens from the lung. Impaired removal of mucus often results in worsening of lung diseases. To understand the mechanisms of mucus transport and to monitor the impact of therapeutic strategies, it is essential to visualize airways and mucus in living animals without disturbing transport processes by intubation or surgically opening the airways. We developed a custom-built optical coherence microscope (OCM) providing a lateral and axial resolution of approximately 1.5 µm with a field of view of 2 mm at up to 150 images/s. Images of the intact trachea and its mucus transport were recorded in anesthetized spontaneously breathing mice. NaCl solution (0.9% and 7%) or Lipopolysaccharide were applied intranasally. OCM resolved detailed structure of the trachea and enabled measuring the airway surface liquid (ASL) thickness through the tracheal wall. Without stimulation, the amount of ASL was only a few µm above the epithelium and remained constant. After intranasal application of 30 µl saline at different concentrations, an early fast cough-like fluid removal with velocities higher than 1 mm/s was observed that removed a high amount of liquid. The ASL thickness increased transiently and quickly returned to levels before stimulation. In contrast to saline, application of Lipopolysaccharide induced substantial mucus release and an additional slow mucus transport by ciliary beating (around 100 µm/s) towards the larynx was observed. In conclusion, OCM is appropriate unique tool to study mechanisms of mucus transport in the airways and effects of therapeutic interventions in living animals.

  12. Transpulmonary pressures and lung mechanics with glossopharyngeal insufflation and exsufflation beyond normal lung volumes in competitive breath-hold divers.

    Science.gov (United States)

    Loring, Stephen H; O'Donnell, Carl R; Butler, James P; Lindholm, Peter; Jacobson, Francine; Ferrigno, Massimo

    2007-03-01

    Throughout life, most mammals breathe between maximal and minimal lung volumes determined by respiratory mechanics and muscle strength. In contrast, competitive breath-hold divers exceed these limits when they employ glossopharyngeal insufflation (GI) before a dive to increase lung gas volume (providing additional oxygen and intrapulmonary gas to prevent dangerous chest compression at depths recently greater than 100 m) and glossopharyngeal exsufflation (GE) during descent to draw air from compressed lungs into the pharynx for middle ear pressure equalization. To explore the mechanical effects of these maneuvers on the respiratory system, we measured lung volumes by helium dilution with spirometry and computed tomography and estimated transpulmonary pressures using an esophageal balloon after GI and GE in four competitive breath-hold divers. Maximal lung volume was increased after GI by 0.13-2.84 liters, resulting in volumes 1.5-7.9 SD above predicted values. The amount of gas in the lungs after GI increased by 0.59-4.16 liters, largely due to elevated intrapulmonary pressures of 52-109 cmH(2)O. The transpulmonary pressures increased after GI to values ranging from 43 to 80 cmH(2)O, 1.6-2.9 times the expected values at total lung capacity. After GE, lung volumes were reduced by 0.09-0.44 liters, and the corresponding transpulmonary pressures decreased to -15 to -31 cmH(2)O, suggesting closure of intrapulmonary airways. We conclude that the lungs of some healthy individuals are able to withstand repeated inflation to transpulmonary pressures far greater than those to which they would normally be exposed.

  13. The importance of clinical monitoring for compliance with Continuous Positive Airway Pressure.

    Science.gov (United States)

    Pelosi, Lucas B; Silveira, Mariana L C; Eckeli, Alan L; Chayamiti, Emilia M P C; Almeida, Leila A; Sander, Heidi H; Küpper, Daniel S; Valera, Fabiana C P

    Obstructive sleep apnea syndrome is currently a public health problem of great importance. When misdiagnosed or improperly treated, it can lead to serious consequences on patients' quality of life. The gold standard treatment for cases of obstructive sleep apnea syndrome, especially in mild to severe and symptomatic cases, is continuous positive airway pressure therapy. Compliance with continuous positive airway pressure therapy is directly dependent on the active participation of the patient, which can be influenced by several factors. The objective of this study is to describe the factors related to compliance with continuous positive airway pressure therapy, and to analyze which associated factors directly influence the efficiency of the treatment. Patients who received continuous positive airway pressure therapy through the Municipal Health Department of the city of Ribeirão Preto were recruited. A structured questionnaire was administered to the patients. Compliance with continuous positive airway pressure therapy was assessed by average hours of continuous positive airway pressure therapy usage per night. Patients with good compliance (patients using continuous positive airway pressure therapy ≥4h/night) were compared to those with poor compliance (patients using <4h/night). 138 patients were analyzed: 77 (55.8%) were considered compliant while 61 (44.2%) were non-compliant. The comparison between the two groups showed that regular monitoring by a specialist considerably improved compliance with continuous positive airway pressure therapy (odds ratio, OR=2.62). Compliance with continuous positive airway pressure therapy is related to educational components, which can be enhanced with continuous and individualized care to patients with obstructive sleep apnea syndrome. Copyright © 2016 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  14. Deep breathing exercises with positive expiratory pressure in patients with multiple sclerosis - a randomized controlled trial.

    Science.gov (United States)

    Westerdahl, Elisabeth; Wittrin, Anna; Kånåhols, Margareta; Gunnarsson, Martin; Nilsagård, Ylva

    2016-11-01

    Breathing exercises with positive expiratory pressure are often recommended to patients with advanced neurological deficits, but the potential benefit in multiple sclerosis (MS) patients with mild and moderate symptoms has not yet been investigated in randomized controlled trials. To study the effects of 2 months of home-based breathing exercises for patients with mild to moderate MS on respiratory muscle strength, lung function, and subjective breathing and health status outcomes. Forty-eight patients with MS according to the revised McDonald criteria were enrolled in a randomized controlled trial. Patients performing breathing exercises (n = 23) were compared with a control group (n = 25) performing no breathing exercises. The breathing exercises were performed with a positive expiratory pressure device (10-15 cmH 2 O) and consisted of 30 slow deep breaths performed twice a day for 2 months. Respiratory muscle strength (maximal inspiratory and expiratory pressure at the mouth), spirometry, oxygenation, thoracic excursion, subjective perceptions of breathing and self-reported health status were evaluated before and after the intervention period. Following the intervention, there was a significant difference between the breathing group and the control group regarding the relative change in lung function, favoring the breathing group (vital capacity: P < 0.043; forced vital capacity: P < 0.025). There were no other significant differences between the groups. Breathing exercises may be beneficial in patients with mild to moderate stages of MS. However, the clinical significance needs to be clarified, and it remains to be seen whether a sustainable effect in delaying the development of respiratory dysfunction in MS can be obtained. © 2015 The Authors. The Clinical Respiratory Journal published by John Wiley & Sons Ltd.

  15. Positive airway pressure adherence and subthreshold adherence in posttraumatic stress disorder patients with comorbid sleep apnea

    Directory of Open Access Journals (Sweden)

    Krakow BJ

    2017-11-01

    Full Text Available Barry J Krakow,1–3 Jessica J Obando,2 Victor A Ulibarri,1,2 Natalia D McIver1,2 1Sleep & Human Health Institute, 2Maimonides Sleep Arts & Sciences, Albuquerque, 3Los Alamos Medical Center, Los Alamos, NM, USA Study objectives: Patients with comorbid posttraumatic stress disorder (PTSD and obstructive sleep apnea (OSA manifest low adherence to continuous positive airway pressure (CPAP due to fixed, pressure-induced expiratory pressure intolerance (EPI, a subjective symptom and objective sign aggravated by anxiety sensitivity and somatosensory amplification. As advanced PAP therapy modes (ie, auto-bilevel PAP [ABPAP] or adaptive servo-ventilation [ASV] may address these side effects, we hypothesized such treatment would be associated with decreased expiratory intolerance and increased adherence in posttraumatic stress patients with co-occurring OSA.Methods: We reviewed charts of 147 consecutive adult patients with moderately severe posttraumatic stress symptoms and objectively diagnosed OSA. All patients failed or rejected CPAP and were manually titrated on auto-adjusting, dual-pressure ABPAP or ASV modes in the sleep laboratory, a technique to eliminate flow limitation breathing events while resolving EPI. Patients were then prescribed either mode of therapy. Follow-up encounters assessed patient use, and objective data downloads (ODDs measured adherence.Results: Of 147 charts reviewed, 130 patients were deemed current PAP users, and 102 provided ODDs: 64 used ASV and 38 used ABPAP. ODDs yielded three groups: 59 adherent per insurance conventions, 19 subthreshold compliant partial users, and 24 noncompliant. Compliance based on available downloads was 58%, notably higher than recently reported rates in PTSD patients with OSA. Among the 19 partial users, 17 patients were minutes of PAP use or small percentages of nights removed from meeting insurance compliance criteria for PAP devices.Conclusion: Research is warranted on advanced PAP modes in

  16. Work of breathing using different interfaces in spontaneous positive pressure ventilation: helmet, face-mask, and endotracheal tube.

    Science.gov (United States)

    Oda, Shinya; Otaki, Kei; Yashima, Nozomi; Kurota, Misato; Matsushita, Sachiko; Kumasaka, Airi; Kurihara, Hutaba; Kawamae, Kaneyuki

    2016-08-01

    Noninvasive positive pressure ventilation (NPPV) using a helmet is expected to cause inspiratory trigger delay due to the large collapsible and compliant chamber. We compared the work of breathing (WOB) of NPPV using a helmet or a full face-mask with that of invasive ventilation by tracheal intubation. We used a lung model capable of simulating spontaneous breathing (LUNGOO; Air Water Inc., Japan). LUNGOO was set at compliance (C) = 50 mL/cmH2O and resistance (R) = 5 cmH2O/L/s for normal lung simulation, C = 20 mL/cmH2O and R = 5 cmH2O/L/s for restrictive lung, and C = 50 mL/cmH2O and R = 20 cmH2O/L/s for obstructive lung. Muscle pressure was fixed at 25 cmH2O and respiratory rate at 20 bpm. Pressure support ventilation and continuous positive airway pressure were performed with each interface placed on a dummy head made of reinforced plastic that was connected to LUNGOO. We tested the inspiratory WOB difference between the interfaces with various combinations of ventilator settings (positive end-expiratory pressure 5 cmH2O; pressure support 0, 5, and 10 cmH2O). In the normal lung and restrictive lung models, WOB decreased more with the face-mask than the helmet, especially when accompanied by the level of pressure support. In the obstructive lung model, WOB with the helmet decreased compared with the other two interfaces. In the mixed lung model, there were no significant differences in WOB between the three interfaces. NPPV using a helmet is more effective than the other interfaces for WOB in obstructive lung disease.

  17. Routine use of humidification with nasal continuous positive airway pressure.

    Science.gov (United States)

    Worsnop, C J; Miseski, S; Rochford, P D

    2010-09-01

    Heated humidification can reduce nasal symptoms caused by continuous positive airway pressure (CPAP) treatment, but its routine use has not been studied over the medium term in a randomized controlled trial. The aim of this study is to determine if heated humidification would reduce nasal symptoms and improve adherence with CPAP treatment in all patients with sleep apnoea irrespective of whether they had nasal symptoms initially. A randomized, parallel group design. Patients were treated for 3 months with a Fisher & Paykel HC201 pump with built-in heated humidification, or with the heater disabled and without water. Adherence was measured with a timer built into the pumps. Nasal symptoms were measured with a 10-cm visual analogue scale. There were 25 in the humidification group and 29 in the non-humidification group. After 12 weeks mean (standard deviation) adherence with CPAP was 4.7 (2.4) and 4.5 (2.2) hours per night respectively. Nasal symptoms that were reduced were nose blocked* 6 (12), 18 (26); sneezing* 4 (8), 15 (25); dry nose* 8 (12), 24 (33); stuffy nose* 7 (14), 22(31); dry mouth* 13 (18), 33(36); and runny nose* 6 (17), 14 (29). Parameters marked with an asterisk '*' had P humidification with CPAP in all patients with sleep apnoea reduced nasal symptoms, but did not improve adherence. © 2010 The Authors. Internal Medicine Journal © 2010 Royal Australasian College of Physicians.

  18. Nasal continuous positive airway pressure treatment: current realities and future.

    Science.gov (United States)

    Berthon-Jones, M; Lawrence, S; Sullivan, C E; Grunstein, R

    1996-11-01

    Nasal continuous positive airway pressure (CPAP) is a highly effective treatment for obstructive sleep apnea syndrome. The apnea/hypopnea index (AHI) is reduced 10-fold, but the patient dropout rate is up to 30%, and usage is typically 20/hour were recruited, with written informed consent. Subjects slept for a diagnostic night, followed by a treatment night, in the laboratory, using the AutoSet system with full polysomnographic monitoring of respiratory and sleep variables. Arousals were scored using ASDA criteria. Hypopneas were scored when there was a 50% reduction in ventilation for > 10 seconds, associated with a 4% drop in oxygen saturation. For comparison, the ASDA arousal index in 16 normal subjects (without nasal CPAP) is provided. Results are given as mean +/- standard error of the mean. AHI was reduced from 55 +/- 3 to 1.5 +/- 0.35 events/hour (p < 0.0001). The arousal index was reduced from 65 +/- 3 to 18 +/- 2 events/hour (p < 0.0001), identical to the value in the 16 healthy normal subjects. There was a 158% +/- 21% increase in slow-wave sleep (p = 0.01) and a 186% +/- 27% increase in rapid eye movement sleep (p = 0.013). The AutoSet self-adjusting nasal CPAP system adequately treats obstructive sleep apnea syndrome on the first night under laboratory conditions.

  19. Continuous positive airway pressure with helmet versus mask in infants with bronchiolitis: an RCT.

    Science.gov (United States)

    Chidini, Giovanna; Piastra, Marco; Marchesi, Tiziana; De Luca, Daniele; Napolitano, Luisa; Salvo, Ida; Wolfler, Andrea; Pelosi, Paolo; Damasco, Mirco; Conti, Giorgio; Calderini, Edoardo

    2015-04-01

    Noninvasive continuous positive airway pressure (CPAP) is usually applied with a nasal or facial mask to treat mild acute respiratory failure (ARF) in infants. A pediatric helmet has now been introduced in clinical practice to deliver CPAP. This study compared treatment failure rates during CPAP delivered by helmet or facial mask in infants with respiratory syncytial virus-induced ARF. In this multicenter randomized controlled trial, 30 infants with respiratory syncytial virus-induced ARF were randomized to receive CPAP by helmet (n = 17) or facial mask (n = 13). The primary endpoint was treatment failure rate (defined as due to intolerance or need for intubation). Secondary outcomes were CPAP application time, number of patients requiring sedation, and complications with each interface. Compared with the facial mask, CPAP by helmet had a lower treatment failure rate due to intolerance (3/17 [17%] vs 7/13 [54%], P = .009), and fewer infants required sedation (6/17 [35%] vs 13/13 [100%], P = .023); the intubation rates were similar. In successfully treated patients, CPAP resulted in better gas exchange and breathing pattern with both interfaces. No major complications due to the interfaces occurred, but CPAP by mask had higher rates of cutaneous sores and leaks. These findings confirm that CPAP delivered by helmet is better tolerated than CPAP delivered by facial mask and requires less sedation. In addition, it is safe to use and free from adverse events, even in a prolonged clinical setting. Copyright © 2015 by the American Academy of Pediatrics.

  20. Randomized trial of prongs or mask for nasal continuous positive airway pressure in preterm infants.

    LENUS (Irish Health Repository)

    Kieran, Emily A

    2012-11-01

    To determine whether nasal continuous positive airway pressure (NCPAP) given with nasal prongs compared with nasal mask reduces the rate of intubation and mechanical ventilation in preterm infants within 72 hours of starting therapy.

  1. Reduced local immune response with continuous positive airway pressure during one-lung ventilation for oesophagectomy

    NARCIS (Netherlands)

    Verhage, R. J. J.; Boone, J.; Rijkers, G. T.; Cromheecke, G. J.; Kroese, A. C.; Weijs, T. J.; Borel Rinkes, I. H. M.; van Hillegersberg, R.

    2014-01-01

    Background. Transthoracic oesophagectomy requires prolonged one-lung ventilation causing systemic and local inflammatory responses. Application of continuous positive airway pressure (CPAP) to the collapsed lung potentially reduces pulmonary damage, hypoxia, and consequent inflammation. This

  2. Negative Pressure Pulmonary Edema Following use of Laryngeal Mask Airway (LMA

    Directory of Open Access Journals (Sweden)

    Yesim Bayraktar

    2013-06-01

    Full Text Available Negative pressure pulmonary edema (NPPE following upper airway obstruction is a non-cardiogenic pulmonary edema. The first cause in the etiology of NPPE is developed laryngospasm after intubation or extubation, while the other causes are epiglotitis, croup, hiccups, foreign body aspiration, pharyngeal hematoma and oropharyngeal tumors.The Late diagnosis and treatment causes high morbidity and mortality. The protection of the airway and maintainance of arterial oxygenation will be life saving.In this article we aimed to report  a case of negative pressure pulmonary edema, resolved succesfully after treatment, following use of laryngeal mask airway (LMA.

  3. Evaluation of a new pediatric positive airway pressure mask.

    Science.gov (United States)

    Kushida, Clete A; Halbower, Ann C; Kryger, Meir H; Pelayo, Rafael; Assalone, Valerie; Cardell, Chia-Yu; Huston, Stephanie; Willes, Leslee; Wimms, Alison J; Mendoza, June

    2014-09-15

    The choice and variety of pediatric masks for continuous positive airway pressure (CPAP) is limited in the US. Therefore, clinicians often prescribe modified adult masks. Until recently a mask for children aged mask for children aged 2-7 years (Pixi; ResMed Ltd, Sydney, Australia). Patients aged 2-7 years were enrolled and underwent in-lab baseline polysomnography (PSG) using their previous mask, then used their previous mask and the VPAP III ST-A flow generator for ≥ 10 nights at home. Thereafter, patients switched to the Pixi mask for ≥ 2 nights before returning for a PSG during PAP therapy via the Pixi mask. Patients then used the Pixi mask at home for ≥ 21 nights. Patients and their parents/guardians returned to the clinic for follow-up and provided feedback on the Pixi mask versus their previous mask. AHI with the Pixi mask was 1.1 ± 1.5/h vs 2.6 ± 5.4/h with the previous mask (p = 0.3538). Parents rated the Pixi mask positively for: restfulness of the child's sleep, trouble in getting the child to sleep, and trouble in having the child stay asleep. The Pixi mask was also rated highly for leaving fewer or no marks on the upper lip and under the child's ears, and being easy to remove. The Pixi mask is suitable for children aged 2-7 years and provides an alternative to other masks available for PAP therapy in this age group. © 2014 American Academy of Sleep Medicine.

  4. Use of Respiratory Support in the Biphase Ventilation Airway Mode in the Newborn

    OpenAIRE

    S. N. Koval; A. Ye. Kulagin

    2006-01-01

    Biphasic positive airway pressure (BIPAP) (also known as DuoPAP, BiLevel, BiVent, PCV+, SPAP) is a mode of ventilation with cycling variations between two continuous positive airway pressure levels. It is a mixture of pressure controlled ventilation and spontaneous breathing, which is unrestricted in each phase of the respiratory cycle. The volume displacement caused by the difference between Phigh and Plow airway pressure level. The phase time ratio (PTR — the BIPAP frequency) is calculated ...

  5. A comparison between the v-gel supraglottic airway device and the cuffed endotracheal tube for airway management in spontaneously breathing cats during isoflurane anaesthesia

    NARCIS (Netherlands)

    van Oostrom, H.; Krauss, M.W.; Sap, R.

    2013-01-01

    Abstract OBJECTIVE: To compare airway management using the v-gel supraglottic airway device (v-gel SGAD) to that using an endotracheal tube (ETT), with respect to practicability, leakage of volatile anaesthetics and upper airway discomfort in cats. STUDY DESIGN: Prospective, randomized clinical

  6. Randomised Comparison of the AMBU AuraOnce Laryngeal Mask and the LMA Unique Laryngeal Mask Airway in Spontaneously Breathing Adults

    OpenAIRE

    Williams, Daryl Lindsay; Zeng, James M.; Alexander, Karl D.; Andrews, David T.

    2012-01-01

    We conducted a randomised single-blind controlled trial comparing the LMA-Unique (LMAU) and the AMBU AuraOnce (AMBU) disposable laryngeal mask in spontaneously breathing adult patients undergoing general anaesthesia. Eighty-two adult patients (ASA status I–IV) were randomly allocated to receive the LMAU or AMBU and were blinded to device selection. Patients received a standardized anesthetic and all airway devices were inserted by trained anaesthetists. Size selection was guided by manufactur...

  7. Absence of effect of nasal continuous positive airway pressure on the esophageal phase of nutritive swallowing in newborn lambs.

    Science.gov (United States)

    Djeddi, Djamal; Cantin, Danny; Samson, Nathalie; Tian, Hao; Praud, Jean-Paul

    2013-08-01

    It is presently recommended that oral feeding be started in premature infants as soon as possible, often at an age at which nasal continuous positive airway pressure (nCPAP) is still required for ventilatory support. Our previous data showed that application of nCPAP up to 10 cmH2O in full-term lambs had no deleterious effect on cardiorespiratory safety, feeding efficiency, or on nutritive swallowing-breathing coordination. Besides fear of swallowing-breathing coordination disturbances, esophageal motility disruption by nCPAP could be a reason to delay oral feeding. To our knowledge, no study has focused on the effects of nCPAP on esophageal motility in the neonatal period. The aim of the present study was therefore to further assess the effects of nCPAP on oral feeding by assessing its effects on the esophageal phase of nutritive swallowing (nutritive esophagodeglutition). Six full-term lambs, ages 2 to 3 days, underwent esophageal multichannel intraluminal impedance-pH monitoring. Lambs were bottle-fed under 2 randomized conditions, namely spontaneous breathing and nCPAP 6 cmH(2)O. Beyond confirmation of unaltered feeding efficiency, analysis of multiple variables measured by impedance monitoring revealed that nCPAP 6 does not alter nutritive esophagodeglutition in any way (nCPAP vs spontaneous breathing, P > 0.1 for all variables). offering further support to neonatologists pleading for initiation of oral feeding in infants still on nCPAP, the present results set the foundations for similar clinical studies in preterm human infants to confirm the absence of effects of nCPAP on nutritive swallowing.

  8. Comparison of Ambient and Atmospheric Pressure Ion Sources for Cystic Fibrosis Exhaled Breath Condensate Ion Mobility-Mass Spectrometry Metabolomics

    Science.gov (United States)

    Zang, Xiaoling; Pérez, José J.; Jones, Christina M.; Monge, María Eugenia; McCarty, Nael A.; Stecenko, Arlene A.; Fernández, Facundo M.

    2017-08-01

    Cystic fibrosis (CF) is an autosomal recessive disorder caused by mutations in the gene that encodes the cystic fibrosis transmembrane conductance regulator (CFTR) protein. The vast majority of the mortality is due to progressive lung disease. Targeted and untargeted CF breath metabolomics investigations via exhaled breath condensate (EBC) analyses have the potential to expose metabolic alterations associated with CF pathology and aid in assessing the effectiveness of CF therapies. Here, transmission-mode direct analysis in real time traveling wave ion mobility spectrometry time-of-flight mass spectrometry (TM-DART-TWIMS-TOF MS) was tested as a high-throughput alternative to conventional direct infusion (DI) electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) methods, and a critical comparison of the three ionization methods was conducted. EBC was chosen as the noninvasive surrogate for airway sampling over expectorated sputum as EBC can be collected in all CF subjects regardless of age and lung disease severity. When using pooled EBC collected from a healthy control, ESI detected the most metabolites, APCI a log order less, and TM-DART the least. TM-DART-TWIMS-TOF MS was used to profile metabolites in EBC samples from five healthy controls and four CF patients, finding that a panel of three discriminant EBC metabolites, some of which had been previously detected by other methods, differentiated these two classes with excellent cross-validated accuracy.

  9. Pressure Dependence of the Radial Breathing Mode of Carbon Nanotubes: The Effect of Fluid Adsorption

    Science.gov (United States)

    Longhurst, M. J.; Quirke, N.

    2007-04-01

    The pressure dependence of shifts in the vibrational modes of individual carbon nanotubes is strongly affected by the nature of the pressure transmitting medium as a result of adsorption at the nanotube surface. The adsorbate is treated as an elastic shell which couples with the radial breathing mode (RBM) of the nanotube via van der Waal interactions. Using analytical methods as well as molecular simulation, we observe a low frequency breathing mode for the adsorbed fluid at ˜50cm-1, as well as diameter dependent upshifts in the RBM frequency with pressure, suggesting metallic nanotubes may wet more than semiconducting ones.

  10. Moderately high frequency ventilation with a conventional ventilator allows reduction of tidal volume without increasing mean airway pressure.

    Science.gov (United States)

    Cordioli, Ricardo Luiz; Park, Marcelo; Costa, Eduardo Leite Vieira; Gomes, Susimeire; Brochard, Laurent; Amato, Marcelo Britto Passos; Azevedo, Luciano Cesar Pontes

    2014-12-01

    The aim of this study was to explore if positive-pressure ventilation delivered by a conventional ICU ventilator at a moderately high frequency (HFPPV) allows a safe reduction of tidal volume (V T) below 6 mL/kg in a porcine model of severe acute respiratory distress syndrome (ARDS) and at a lower mean airway pressure than high-frequency oscillatory ventilation (HFOV). This is a prospective study. In eight pigs (median weight 34 [29,36] kg), ARDS was induced by pulmonary lavage and injurious ventilation. The animals were ventilated with a randomized sequence of respiratory rates: 30, 60, 90, 120, 150, followed by HFOV at 5 Hz. At each step, V T was adjusted to allow partial pressure of arterial carbon dioxide (PaCO2) to stabilize between 57 and 63 mmHg. Data are shown as median [P25th,P75th]. After lung injury, the PaO2/FiO2 (P/F) ratio was 92 [63,118] mmHg, pulmonary shunt 26 [17,31]%, and static compliance 11 [8,14] mL/cmH2O. Positive end-expiratory pressure (PEEP) was 14 [10,17] cmH2O. At 30 breaths/min, V T was higher than 6 (7.5 [6.8,10.2]) mL/kg, but at all higher frequencies, V T could be reduced and PaCO2 maintained, leading to reductions in plateau pressures and driving pressures. For frequencies of 60 to 150/min, V T progressively fell from 5.2 [5.1,5.9] to 3.8 [3.7,4.2] mL/kg (p mechanics, auto-PEEP generation, hemodynamics, or gas exchange. Mean airway pressure was maintained constant and was increased only during HFOV. During protective mechanical ventilation, HFPPV delivered by a conventional ventilator in a severe ARDS swine model safely allows further tidal volume reductions. This strategy also allowed decreasing airway pressures while maintaining stable PaCO2 levels.

  11. Short term evaluation of respiratory effort by premature infants supported with bubble nasal continuous airway pressure using Seattle-PAP and a standard bubble device

    Science.gov (United States)

    Welty, Stephen E.; Rusin, Craig G.; Stanberry, Larissa I.; Mandy, George T.; Gest, Alfred L.; Ford, Jeremy M.; Backes, Carl H.; Richardson, C. Peter; Howard, Christopher R.; Hansen, Thomas N.

    2018-01-01

    Background Almost one million prematurely born infants die annually from respiratory insufficiency, predominantly in countries with limited access to respiratory support for neonates. The primary hypothesis tested in the present study was that a modified device for bubble nasal continuous positive airway pressure (Bn-CPAP) would provide lower work of spontaneous breathing, estimated by esophageal pressure-rate products. Methods Infants born CPAP with FiO2 CPAP, then 2 h with Bn-CPAP using a modified bubble device presently termed Seattle-PAP, which produces a different pattern of pressure fluctuations and which provided greater respiratory support in preclinical studies, then 2 h on standard Bn-CPAP. Results All 40 infants enrolled completed the study and follow-up through 36 wks post menstrual age or hospital discharge, whichever came first. No infants were on supplemental oxygen at completion of follow-up. No infants developed pneumothoraces or nasal trauma, and no adverse events attributed to the study were observed. Pressure-rate products on the two devices were not different, but effort of breathing, assessed by areas under esophageal pressure-time curves, was lower with Seattle-PAP than with standard Bn-CPAP. Conclusion Use of Seattle-PAP to implement Bn-CPAP lowers the effort of breathing exerted even by relatively healthy spontaneously breathing premature neonates. Whether the lower effort of breathing observed with Seattle-PAP translates to improvements in neonatal mortality or morbidity will need to be determined by studies in appropriate patient populations. PMID:29590143

  12. Influence of mouth opening on oropharyngeal humidification and temperature in a bench model of neonatal continuous positive airway pressure.

    Science.gov (United States)

    Fischer, Hendrik S; Ullrich, Tim L; Bührer, Christoph; Czernik, Christoph; Schmalisch, Gerd

    2017-02-01

    Clinical studies show that non-invasive respiratory support by continuous positive airway pressure (CPAP) affects gas conditioning in the upper airways, especially in the presence of mouth leaks. Using a new bench model of neonatal CPAP, we investigated the influence of mouth opening on oropharyngeal temperature and humidity. The model features the insertion of a heated humidifier between an active model lung and an oropharyngeal head model to simulate the recurrent expiration of heated, humidified air. During unsupported breathing, physiological temperature and humidity were attained inside the model oropharynx, and mouth opening had no significant effect on oropharyngeal temperature and humidity. During binasal CPAP, the impact of mouth opening was investigated using three different scenarios: no conditioning in the CPAP circuit, heating only, and heated humidification. Mouth opening had a strong negative impact on oropharyngeal humidification in all tested scenarios, but heated humidification in the CPAP circuit maintained clinically acceptable humidity levels regardless of closed or open mouths. The model can be used to test new equipment for use with CPAP, and to investigate the effects of other methods of non-invasive respiratory support on gas conditioning in the presence of leaks. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  13. The Impact of Resonance Frequency Breathing on Measures of Heart Rate Variability, Blood Pressure, and Mood

    Directory of Open Access Journals (Sweden)

    Patrick R. Steffen

    2017-08-01

    Full Text Available Heart rate variability biofeedback (HRVB significantly improves heart rate variability (HRV. Breathing at resonance frequency (RF, approximately 6 breaths/min constitutes a key part of HRVB training and is hypothesized to be a pathway through which biofeedback improves HRV. No studies to date, however, have experimentally examined whether RF breathing impacts measures of HRV. The present study addressed this question by comparing three groups: the RF group breathed at their determined RF for 15 min; the RF + 1 group breathed at 1 breath/min higher than their determined RF for 15 min; and the third group sat quietly for 15 min. After this 15-min period, all groups participated in the Paced Auditory Serial Addition Task (PASAT for 8 min, and then sat quietly during a 10-min recovery period. HRV, blood pressure, and mood were measured throughout the experiment. Groups were not significantly different on any of the measures at baseline. After the breathing exercise, the RF group reported higher positive mood than the other two groups and a significantly higher LF/HF HRV ratio relative to the control group, a key goal in HRVB training (p < 0.05. Additionally, the RF group showed lower systolic blood pressure during the PASAT and during the recovery period relative to the control group, with the RF + 1 group not being significantly different from either group (p < 0.05. Overall, RF breathing appears to play an important role in the positive effect HRVB has on measures of HRV.

  14. Continuous Positive Airway Pressure During Exercise Improves Walking Time in Patients Undergoing Inpatient Cardiac Rehabilitation After Coronary Artery Bypass Graft Surgery: A RANDOMIZED CONTROLLED TRIAL.

    Science.gov (United States)

    Pantoni, Camila Bianca Falasco; Di Thommazo-Luporini, Luciana; Mendes, Renata Gonçalves; Caruso, Flávia Cristina Rossi; Mezzalira, Daniel; Arena, Ross; Amaral-Neto, Othon; Catai, Aparecida Maria; Borghi-Silva, Audrey

    2016-01-01

    Continuous positive airway pressure (CPAP) has been used as an effective support to decrease the negative pulmonary effects of coronary artery bypass graft (CABG) surgery. However, it is unknown whether CPAP can positively influence patients undergoing CABG during exercise. This study evaluated the effectiveness of CPAP on the first day of ambulation after CABG in patients undergoing inpatient cardiac rehabilitation (CR). Fifty-four patients after CABG surgery were randomly assigned to receive either inpatient CR and CPAP (CPG) or standard CR without CPAP (CG). Cardiac rehabilitation included walking and CPAP pressures were set between 10 to 12 cmH2O. Participants were assessed on the first day of walking at rest and during walking. Outcome measures included breathing pattern variables, exercise time in seconds (ETs), dyspnea/leg effort ratings, and peripheral oxygen saturation (SpO2). Twenty-seven patients (13 CPG vs 14 CG) completed the study. Compared with walking without noninvasive ventilation assistance, CPAP increased ETs by 43.4 seconds (P = .040) during walking, promoted better thoracoabdominal coordination, increased ventilation during walking by 12.5 L/min (P = .001), increased SpO2 values at the end of walking by 2.6% (P = .016), and reduced dyspnea ratings by 1 point (P = .008). Continuous positive airway pressure can positively influence exercise tolerance, ventilatory function, and breathing pattern in response to a single bout of exercise after CABG.

  15. Airway obstruction and gas leak during mask ventilation of preterm infants in the delivery room.

    LENUS (Irish Health Repository)

    2011-07-01

    Preterm infants with inadequate breathing receive positive pressure ventilation (PPV) by mask with variable success. The authors examined recordings of PPV given to preterm infants in the delivery room for prevalence of mask leak and airway obstruction.

  16. Association of Lung Inflammatory Cells with Small Airways Function and Exhaled Breath Markers in Smokers - Is There a Specific Role for Mast Cells?

    Directory of Open Access Journals (Sweden)

    Yvonne Nussbaumer-Ochsner

    Full Text Available Smoking is associated with a mixed inflammatory infiltrate in the airways. We evaluated whether airway inflammation in smokers is related to lung function parameters and inflammatory markers in exhaled breath.Thirty-seven smokers undergoing lung resection for primary lung cancer were assessed pre-operatively by lung function testing including single-breath-nitrogen washout test (sb-N2-test, measurement of fractional exhaled nitric oxide (FeNO and pH/8-isoprostane in exhaled breath condensate (EBC. Lung tissue sections containing cancer-free large (LA and small airways (SA were stained for inflammatory cells. Mucosal (MCT respectively connective tissue mast cells (MCTC and interleukin-17A (IL-17A expression by mast cells was analysed using a double-staining protocol.The median number of neutrophils, macrophages and mast cells infiltrating the lamina propria and adventitia of SA was higher than in LA. Both MCTC and MCT were higher in the lamina propria of SA compared to LA (MCTC: 49 vs. 27.4 cells/mm2; MCT: 162.5 vs. 35.4 cells/mm2; P<0.005 for both instances. IL-17A expression was predominantly detected in MCTC of LA. Significant correlations were found for the slope of phase III % pred. of the sb-N2-test (rs= -0.39, for the FEV1% pred. (rs= 0.37 and for FEV1/FVC ratio (rs=0.38 with MCT in SA (P<0.05 for all instances. 8-isoprostane concentration correlated with the mast cells in the SA (rs=0.44, there was no correlation for pH or FeNO with cellular distribution in SA.Neutrophils, macrophages and mast cells are more prominent in the SA indicating that these cells are involved in the development of small airway dysfunction in smokers. Among these cell types, the best correlation was found for mast cells with lung function parameters and inflammatory markers in exhaled breath. Furthermore, the observed predominant expression of IL-17A in mast cells warrants further investigation to elucidate their role in smoking-induced lung injury, despite the

  17. Comparison of trapezius squeeze test and jaw thrust as clinical indicators for laryngeal mask airway insertion in spontaneously breathing children

    Science.gov (United States)

    Dinesh Kumar, K. K.; Bhardwaj, Neerja; Yaddanapudi, Sandhya

    2017-01-01

    Background and Aims: It is not known whether trapezius squeeze test (TPZ) is a better clinical test than jaw thrust (JT) to assess laryngeal mask airway (LMA) insertion conditions in children under sevoflurane anesthesia. Material and Methods: After the Institutional Ethics Committee approval and written informed parental consent, 124 American Society of Anesthesiologists I and II children of 2–8 years of age undergoing minor surgical procedures were randomized into TPZ and JT groups. The children were induced with 8% sevoflurane in oxygen at a fresh gas flow of 4 L/min. TPZ or JT was performed after 1 min of start of sevoflurane and then every 20 s till the test was negative, when end-tidal (ET) sevoflurane concentration was noted. Classic LMA of requisite size was inserted by a blinded anesthetist and conditions at the insertion of LMA, insertion time, and the number of attempts of LMA insertion were recorded. Results: The mean LMA insertion time was significantly longer (P < 0.001) for TPZ (145 ± 28.7 sec) compared to JT group (111.8 ± 31.0 sec). ET sevoflurane concentration at the time of LMA insertion was comparable in the two groups. LMA insertion conditions were similar in the two groups. There was no difference between the two groups regarding total number of attempts of LMA insertion. Heart rate (HR) decreased in both groups after LMA insertion (P < 0.001) but TPZ group had significantly lower HR compared with the JT group up to 5 min after LMA insertion (P = 0.03). Conclusion: Both JT and TPZ are equivalent clinical indicators in predicting the optimal conditions of LMA insertion in spontaneously breathing children; however, it takes a longer time to achieve a negative TPZ squeeze test. PMID:28413275

  18. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... specialized CF care and a range of treatment options. Airway Clearance Active Cycle of Breathing Technique Airway ... on their own. Share Facebook Twitter Email More options Print Share Facebook Twitter Email Print Permalink All ...

  19. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... a range of treatment options. Airway Clearance Active Cycle of Breathing Technique Airway Clearance Techniques Autogenic Drainage ... LEGACY GIFT Sponsor a Participant CF Climb CF Cycle for Life Great Strides Xtreme Hike Participate In ...

  20. EXTUBATE: A randomised controlled trial of nasal biphasic positive airway pressure vs. nasal continuous positive airway pressure following extubation in infants less than 30 weeks' gestation: study protocol for a randomised controlled trial

    Directory of Open Access Journals (Sweden)

    Victor Suresh

    2011-12-01

    Full Text Available Abstract Background Respiratory distress syndrome remains a significant problem among premature infants. Mechanical ventilation through an endotracheal tube remains the mainstay of respiratory support but may be associated with lung injury and the development of chronic lung disease of prematurity. Efforts are needed to reduce the duration of mechanical ventilation in favour of less invasive forms of respiratory support and to improve rates of successful extubation. Non-invasive respiratory support has been demonstrated to be less injurious to the premature lung. Standard practice is to use nasal continuous positive airway pressure (n-CPAP following extubation to support the baby's breathing. Many clinicians also use nasal biphasic positive airway pressure (n-BiPAP in efforts to improve rates of successful extubation. However, there is currently no evidence that this confers any advantage over conventional nasal continuous positive airway pressure. Methods We propose an unblinded multi-centre randomised trial comparing n-CPAP with n-BiPAP in babies born before 30 weeks' gestation and less than two weeks old. Babies with congenital abnormalities and severe intra-ventricular haemorrhage will be excluded. 540 babies admitted to neonatal centres in England will be randomised at the time of first extubation attempt. The primary aim of this study is to compare the rate of extubation failure within 48 hours following the first attempt at extubation. The secondary aims are to compare the effect of n-BiPAP and n-CPAP on the following outcomes: 1. Maintenance of successful extubation for 7 days post extubation 2. Oxygen requirement at 28 days of age and at 36 weeks' corrected gestational age 3. Total days on ventilator, n-CPAP/n-BiPAP 4. Number of ventilator days following first extubation attempt 5. pH and partial pressure of carbon dioxide in the first post extubation blood gas 6. Duration of hospital stay 7. Rate of abdominal distension requiring

  1. Bi-level positive airway pressure ventilation for treating heart failure with central sleep apnea that is unresponsive to continuous positive airway pressure.

    Science.gov (United States)

    Dohi, Tomotaka; Kasai, Takatoshi; Narui, Koji; Ishiwata, Sugao; Ohno, Minoru; Yamaguchi, Tetsu; Momomura, Shin-Ichi

    2008-07-01

    Cheyne-Stokes respiration with central sleep apnea (CSR-CSA) is associated with a poor prognosis in patients with heart failure (HF). However, some patients do not respond to continuous positive airway pressure (CPAP), so other therapeutic modalities should be considered, such as bi-level positive airway pressure (PAP), which also assists respiration and might be effective for such patients. The 20 patients with HF because of left ventricular systolic dysfunction were assessed: 8 had ischemic etiology, and all had severe CSA according to the apnea - hypopnea index (AHI) determined by polysomnography. All diagnosed patients underwent repeat polysomnography using CPAP. The AHI improved significantly in 11 (AHI or=15). Bi-level PAP titration significantly improved the AHI in the latter group. Those who were unresponsive to CPAP had significantly lower PaCO(2), higher plasma brain natriuretic peptide (BNP), longer mean duration of CSR and fewer obstructive episodes than CPAP responders. After 6 months of positive airway support with either CPAP (n=9) or bi-level PAP (n=7), BNP levels significantly decreased and left ventricular ejection fraction significantly increased. Bi-level PAP could be an effective alternative for patients with HF and pure CSR-CSA who are unresponsive to CPAP.

  2. Nap-titration : An effective alternative for continuous positive airway pressure titration

    NARCIS (Netherlands)

    Hoekema, A; Stegenga, B; Meinesz, AF; van der Hoeven, JH; Wijkstra, PJ

    When treating Obstructive Steep Apnea-Hypopnea Syndrome (OSAHS) several alternatives for standard (manual) continuous positive airway pressure (CPAP) titration are feasible. A practical alternative is titration without polysomnography during an afternoon nap (Nap-titration). The aim of the present

  3. Adherence to continuous positive airway pressure in adults with an intellectual disability

    NARCIS (Netherlands)

    Luijks, K.A.; Vandenbussche, N.L.; Pevernagie, D.; Overeem, S.; Pillen, S.

    STUDY OBJECTIVES: This retrospective study evaluated the feasibility of continuous positive airway pressure (CPAP) therapy in adults with intellectual disabilities (ID). METHODS: CPAP therapy of 24 obstructive sleep apnea syndrome (OSA) patients with ID were compared to age- and sex-matched adults

  4. Improved oxygenation during standing performance of deep breathing exercises with positive expiratory pressure after cardiac surgery: A randomized controlled trial.

    Science.gov (United States)

    Pettersson, Henrik; Faager, Gun; Westerdahl, Elisabeth

    2015-09-01

    Breathing exercises after cardiac surgery are often performed in a sitting position. It is unknown whether oxygenation would be better in the standing position. The aim of this study was to evaluate oxygenation and subjective breathing ability during sitting vs standing performance of deep breathing exercises on the second day after cardiac surgery. Patients undergoing coronary artery bypass grafting (n = 189) were randomized to sitting (controls) or standing. Both groups performed 3 × 10 deep breaths with a positive expiratory pressure device. Peripheral oxygen saturation was measured before, directly after, and 15 min after the intervention. Subjective breathing ability, blood pressure, heart rate, and pain were assessed. Oxygenation improved significantly in the standing group compared with controls directly after the breathing exercises (p < 0.001) and after 15 min rest (p = 0.027). The standing group reported better deep breathing ability compared with controls (p = 0.004). A slightly increased heart rate was found in the standing group (p = 0.047). After cardiac surgery, breathing exercises with positive expiratory pressure, performed in a standing position, significantly improved oxygenation and subjective breathing ability compared with sitting performance. Performance of breathing exercises in the standing position is feasible and could be a valuable treatment for patients with postoperative hypoxaemia.

  5. Effect of different levels of continuous positive airway pressure on the 99mTc-DTPA lung clearance

    Directory of Open Access Journals (Sweden)

    Dulciane Nunes Paiva

    2014-04-01

    Full Text Available Backgound and Objectives: Positive airway pressure continues (CPAP produces significant hemodynamic changes that may influence the variability of breathing pattern and heart rate, acting as an additional therapy to prevent atelectasis and to combat hypoxia. The rate of inhaled 99 m Technetiumdiethylenetriaminepentaacetic acid (99mTc-DTPA, along with changes in the lung epithelium cause an increase in the rate of clearance of this compound. The aim of this study was evaluate the pulmonary clearance rate of 99mTechnetium Diethylenetriaminepentaacetic acid (99mTc-DTPA through the use of different levels of CPAP. Methods: It was a quasi-experimental study involving 17 healthy individuals with normal lung functional. 99mTc-DTPA, as aerosol, was nebulized for 3 minutes with the individual in a sitting position. The pulmonary clearance rate was assessed through pulmonary scintigraphy under spontaneous breathing and under 20 and 10 cmH2 O CPAP in the sitting position. The clearance rate was expressed as the half-time (T½ that is the time for the activity to decrease to 50% of the peak value. Results: 20 cmH2 O CPAP produced significant reduction of the T½ of 99mTc-DTPA in the sitting position (p=0.005. However, 10 cmH2 O CPAP did not alter the T½ of DTPA in the same positions. Conclusion: High levels of continuos positive pressure in normal lungs resulted in faster 99mTc-DTPA clearance moreover, 10 cmH2 O did not alter its clearance rate. KEYWORDS: Noninvasive ventilation. Technetium Tc 99m Pentetate. Radionuclide Imaging.

  6. Verifying the Relative Efficacy between Continuous Positive Airway Pressure Therapy and Its Alternatives for Obstructive Sleep Apnea: A Network Meta-analysis

    Directory of Open Access Journals (Sweden)

    Tingwei Liu

    2017-06-01

    Full Text Available Obstructive sleep apnea (OSA is a common breathing disorder, and continuous positive airway pressure (CPAP therapy together with its alternatives has been developed to treat this disease. This network meta-analysis (NMA was aimed to compare the efficacy of treatments for OSA. Cochrane Library, MEDLINE, and Embase were searched for eligible studies. A conventional and NMA was carried out to compare all therapies. Sleeping characteristics, including Apnea–Hypopnea Index (AHI, Epworth Sleepiness Scale (ESS, arterial oxygen saturation, and arousal index (AI, and changes of blood pressure were selected as outcomes. A total of 84 studies were finally included after rigorous screenings. For the primary outcomes of AHI and ESS, the value of auto-adjusting positive airway pressure (APAP, CPAP, and oral appliance (OA all showed statistically reduction compared with inactive control (IC. Similar observation was obtained in AI, with treatments of the three active interventions. A lower effect of IC in SaO2 was exhibited when compared with APAP, CPAP, and OA. Similar statistically significant results were presented in 24 h systolic blood pressure and 24 h DBP when comparing with CPAP. Our NMA identified CPAP as the most efficacious treatment for OSA patients after the evaluation of sleeping characteristics and blood pressures. In addition, more clinical trials are needed for further investigation due to the existence of inconsistency observed in this study.

  7. Role of Positive Airway Pressure Therapy for Obstructive Sleep Apnea in Patients With Stroke: A Randomized Controlled Trial

    Science.gov (United States)

    Gupta, Anupama; Shukla, Garima; Afsar, Mohammed; Poornima, Shivani; Pandey, Ravindra M.; Goyal, Vinay; Srivastava, Achal; Vibha, Deepti; Behari, Madhuri

    2018-01-01

    Registration: Registry: Clinical Trials Registry - India, CTRI Registration No: CTRI/2016/07.007104, Title: Sleep Disordered Breathing in stroke patients: Effect of treatment trial, URL: http://ctri.nic.in/Clinicaltrials/showallp.php?mid1=8682&EncHid=&userName=sleep%20disordered%20breathing Citation: Gupta A, Shukla G, Afsar M, Poornima S, Pandey RM, Goyal V, Srivastava A, Vibha D, Behari M. Role of positive airway pressure therapy for obstructive sleep apnea in patients with stroke: a randomized controlled trial. J Clin Sleep Med. 2018;14(4):511–521. PMID:29609704

  8. Simulation of late inspiratory rise in airway pressure during pressure support ventilation.

    Science.gov (United States)

    Yu, Chun-Hsiang; Su, Po-Lan; Lin, Wei-Chieh; Lin, Sheng-Hsiang; Chen, Chang-Wen

    2015-02-01

    Late inspiratory rise in airway pressure (LIRAP, Paw/ΔT) caused by inspiratory muscle relaxation or expiratory muscle contraction is frequently seen during pressure support ventilation (PSV), although the modulating factors are unknown. We investigated the effects of respiratory mechanics (normal, obstructive, restrictive, or mixed), inspiratory effort (-2, -8, or -15 cm H2O), flow cycle criteria (5-40% peak inspiratory flow), and duration of inspiratory muscle relaxation (0.18-0.3 s) on LIRAP during PSV using a lung simulator and 4 types of ventilators. LIRAP occurred with all lung models when inspiratory effort was medium to high and duration of inspiratory muscle relaxation was short. The normal lung model was associated with the fastest LIRAP, whereas the obstructive lung model was associated with the slowest. Unless lung mechanics were normal or mixed, LIRAP was unlikely to occur when inspiratory effort was low. Different ventilators were also associated with differences in LIRAP speed. Except for within the restrictive lung model, changes in flow cycle level did not abolish LIRAP if inspiratory effort was medium to high. Increased duration of inspiratory relaxation also led to the elimination of LIRAP. Simulation of expiratory muscle contraction revealed that LIRAP occurred only when expiratory muscle contraction occurred sometime after the beginning of inspiration. Our simulation study reveals that both respiratory resistance and compliance may affect LIRAP. Except for under restrictive lung conditions, LIRAP is unlikely to be abolished by simply lowering flow cycle criteria when inspiratory effort is strong and relaxation time is rapid. LIRAP may be caused by expiratory muscle contraction when it occurs during inspiration. Copyright © 2015 by Daedalus Enterprises.

  9. Breath-Hold Diving.

    Science.gov (United States)

    Fitz-Clarke, John R

    2018-03-25

    Breath-hold diving is practiced by recreational divers, seafood divers, military divers, and competitive athletes. It involves highly integrated physiology and extreme responses. This article reviews human breath-hold diving physiology beginning with an historical overview followed by a summary of foundational research and a survey of some contemporary issues. Immersion and cardiovascular adjustments promote a blood shift into the heart and chest vasculature. Autonomic responses include diving bradycardia, peripheral vasoconstriction, and splenic contraction, which help conserve oxygen. Competitive divers use a technique of lung hyperinflation that raises initial volume and airway pressure to facilitate longer apnea times and greater depths. Gas compression at depth leads to sequential alveolar collapse. Airway pressure decreases with depth and becomes negative relative to ambient due to limited chest compliance at low lung volumes, raising the risk of pulmonary injury called "squeeze," characterized by postdive coughing, wheezing, and hemoptysis. Hypoxia and hypercapnia influence the terminal breakpoint beyond which voluntary apnea cannot be sustained. Ascent blackout due to hypoxia is a danger during long breath-holds, and has become common amongst high-level competitors who can suppress their urge to breathe. Decompression sickness due to nitrogen accumulation causing bubble formation can occur after multiple repetitive dives, or after single deep dives during depth record attempts. Humans experience responses similar to those seen in diving mammals, but to a lesser degree. The deepest sled-assisted breath-hold dive was to 214 m. Factors that might determine ultimate human depth capabilities are discussed. © 2018 American Physiological Society. Compr Physiol 8:585-630, 2018. Copyright © 2018 American Physiological Society. All rights reserved.

  10. Spontaneous breathing during lung-protective ventilation in an experimental acute lung injury model: high transpulmonary pressure associated with strong spontaneous breathing effort may worsen lung injury.

    Science.gov (United States)

    Yoshida, Takeshi; Uchiyama, Akinori; Matsuura, Nariaki; Mashimo, Takashi; Fujino, Yuji

    2012-05-01

    We investigated whether potentially injurious transpulmonary pressure could be generated by strong spontaneous breathing and exacerbate lung injury even when plateau pressure is limited to ventilation, each combined with weak or strong spontaneous breathing effort. Inspiratory pressure for low tidal volume ventilation was set at 10 cm H2O and tidal volume at 6 mL/kg. For moderate tidal volume ventilation, the values were 20 cm H2O and 7-9 mL/kg. The groups were: low tidal volume ventilation+spontaneous breathingweak, low tidal volume ventilation+spontaneous breathingstrong, moderate tidal volume ventilation+spontaneous breathingweak, and moderate tidal volume ventilation+spontaneous breathingstrong. Each group had the same settings for positive end-expiratory pressure of 8 cm H2O. Respiratory variables were measured every 60 mins. Distribution of lung aeration and alveolar collapse were histologically evaluated. Low tidal volume ventilation+spontaneous breathingstrong showed the most favorable oxygenation and compliance of respiratory system, and the best lung aeration. By contrast, in moderate tidal volume ventilation+spontaneous breathingstrong, the greatest atelectasis with numerous neutrophils was observed. While we applied settings to maintain plateau pressure at ventilation+spontaneous breathingstrong, transpulmonary pressure rose >33 cm H2O. Both minute ventilation and respiratory rate were higher in the strong spontaneous breathing groups. Even when plateau pressure is limited to mechanical ventilation, transpulmonary pressure and tidal volume should be strictly controlled to prevent further lung injury.

  11. Flexible hemispheric microarrays of highly pressure-sensitive sensors based on breath figure method.

    Science.gov (United States)

    Wang, Zhihui; Zhang, Ling; Liu, Jin; Jiang, Hao; Li, Chunzhong

    2018-05-30

    Recently, flexible pressure sensors featuring high sensitivity, broad sensing range and real-time detection have aroused great attention owing to their crucial role in the development of artificial intelligent devices and healthcare systems. Herein, highly sensitive pressure sensors based on hemisphere-microarray flexible substrates are fabricated via inversely templating honeycomb structures deriving from a facile and static breath figure process. The interlocked and subtle microstructures greatly improve the sensing characteristics and compressibility of the as-prepared pressure sensor, endowing it a sensitivity as high as 196 kPa-1 and a wide pressure sensing range (0-100 kPa), as well as other superior performance, including a lower detection limit of 0.5 Pa, fast response time (10 000 cycles). Based on the outstanding sensing performance, the potential capability of our pressure sensor in capturing physiological information and recognizing speech signals has been demonstrated, indicating promising application in wearable and intelligent electronics.

  12. Comparison of sprinting vs non-sprinting to wean nasal continuous positive airway pressure off in very preterm infants.

    Science.gov (United States)

    Eze, N; Murphy, D; Dhar, V; Rehan, V K

    2018-02-01

    Though nasal continuous positive airway pressure (NCPAP) is commonly used for non-invasive neonatal respiratory support, the optimal method of weaning NCPAP is not established. In this prospective, two-center randomized control trial we hypothesize that gradually increasing spontaneous breathing time off NCPAP increases successful weaning from NCPAP in infants born 0.05). It took 1.3 (1 to 1.75) (median (IQR)) attempts and 7 (7 to 7) days to wean NCPAP off in the sprinting group vs 1.3 (1 to 1.75) attempts and 7 (7 to 10) days in the non-sprinting group (P>0.05). Additionally, no differences in the secondary outcomes of bronchopulmonary dysplasia, severe retinopathy of prematurity (⩾stage 3), periventricular leukomalacia and length of stay were noted between the two groups. Weaning NCPAP via sprinting or non-sprinting protocol is comparable, not only for successful weaning but also for the occurrence of common neonatal morbidities that impact the long-term outcome in premature infants (ClinicalTrials.gov number, NCT02819050).

  13. Comparison of airway pressure release ventilation to conventional mechanical ventilation in the early management of smoke inhalation injury in swine.

    Science.gov (United States)

    Batchinsky, Andriy I; Burkett, Samuel E; Zanders, Thomas B; Chung, Kevin K; Regn, Dara D; Jordan, Bryan S; Necsoiu, Corina; Nguyen, Ruth; Hanson, Margaret A; Morris, Michael J; Cancio, Leopoldo C

    2011-10-01

    The role of airway pressure release ventilation in the management of early smoke inhalation injury has not been studied. We compared the effects of airway pressure release ventilation and conventional mechanical ventilation on oxygenation in a porcine model of acute respiratory distress syndrome induced by wood smoke inhalation. Prospective animal study. Government laboratory animal intensive care unit. Thirty-three Yorkshire pigs. Smoke inhalation injury. Anesthetized female Yorkshire pigs (n = 33) inhaled room-temperature pine-bark smoke. Before injury, the pigs were randomized to receive conventional mechanical ventilation (n = 15) or airway pressure release ventilation (n = 12) for 48 hrs after smoke inhalation. As acute respiratory distress syndrome developed (PaO2/Fio2 ratio conventional mechanical ventilation for 48 hrs and served as time controls. Changes in PaO2/Fio2 ratio, tidal volume, respiratory rate, mean airway pressure, plateau pressure, and hemodynamic variables were recorded. Survival was assessed using Kaplan-Meier analysis. PaO2/Fio2 ratio was lower in airway pressure release ventilation vs. conventional mechanical ventilation pigs at 12, 18, and 24 hrs (p conventional mechanical ventilation animals between 30 and 48 hrs post injury (p animals between 6 and 48 hrs (p conventional mechanical ventilation and airway pressure release ventilation pigs. In this model of acute respiratory distress syndrome caused by severe smoke inhalation in swine, airway pressure release ventilation-treated animals developed acute respiratory distress syndrome faster than conventional mechanical ventilation-treated animals, showing a lower PaO2/Fio2 ratio at 12, 18, and 24 hrs after injury. At other time points, PaO2/Fio2 ratio was not different between conventional mechanical ventilation and airway pressure release ventilation.

  14. Clinical predictors of central sleep apnea evoked by positive airway pressure titration

    OpenAIRE

    Bianchi, Matt; Gannon,Karen; Lovell,Kathy; Merlino,Margaret; Mojica,James; Moro,Marilyn

    2016-01-01

    Marilyn Moro,1 Karen Gannon,1 Kathy Lovell,1 Margaret Merlino,1 James Mojica,2 Matt T Bianchi,1,3 1Neurology Department, 2Pulmonary and Critical Care Medicine, Massachusetts General Hospital, Boston, MA, USA; 3Division of Sleep Medicine, Harvard Medical School, Boston, MA, USA Purpose: Treatment-emergent central sleep apnea (TECSA), also called complex apnea, occurs in 5%–15% of sleep apnea patients during positive airway pressure (PAP) therapy, but the clinical predictors are not w...

  15. Randomised trial of elective continuous positive airway pressure (CPAP) compared with rescue CPAP after extubation

    OpenAIRE

    Robertson, N; Hamilton, P

    1998-01-01

    AIM—To determine if a weaning regimen on flow driver continuous positive airway pressure (CPAP) would decrease the number of ventilator days but increase the number of CPAP days when compared with a rescue regimen.
METHODS—Fifty eight babies of 24-32 weeks gestation with respiratory distress syndrome (RDS) were studied prospectively. After extubation they were randomly allocated to receive CPAP for 72 hours (n=29) according to a weaning regimen, or were placed in headbox ...

  16. The NOFLO trial: low-flow nasal prongs therapy in weaning nasal continuous positive airway pressure in preterm infants.

    LENUS (Irish Health Repository)

    O'Donnell, Sinéad M

    2013-07-01

    To determine if low-flow nasal prongs therapy with room air, compared with no treatment, facilitates weaning from nasal continuous positive airway pressure (NCPAP) in very low birth weight (VLBW, birth weight <1500 g) infants.

  17. Continuous Positive Airway Pressure for Motion Management in Stereotactic Body Radiation Therapy to the Lung: A Controlled Pilot Study

    Energy Technology Data Exchange (ETDEWEB)

    Goldstein, Jeffrey D. [Department of Radiation Oncology, Chaim Sheba Medical Center, Tel Hashomer, Tel Aviv (Israel); Lawrence, Yaacov R. [Department of Radiation Oncology, Chaim Sheba Medical Center, Tel Hashomer, Tel Aviv (Israel); Sackler School of Medicine, Tel Aviv University, Tel Aviv (Israel); Appel, Sarit; Landau, Efrat; Ben-David, Merav A.; Rabin, Tatiana; Benayun, Maoz; Dubinski, Sergey; Weizman, Noam; Alezra, Dror; Gnessin, Hila; Goldstein, Adam M.; Baidun, Khader [Department of Radiation Oncology, Chaim Sheba Medical Center, Tel Hashomer, Tel Aviv (Israel); Segel, Michael J.; Peled, Nir [Department of Pulmonary Medicine, Chaim Sheba Medical Center, Tel Hashomer, Tel Aviv (Israel); Sackler School of Medicine, Tel Aviv University, Tel Aviv (Israel); Symon, Zvi, E-mail: symonz@sheba.health.gov.il [Department of Radiation Oncology, Chaim Sheba Medical Center, Tel Hashomer, Tel Aviv (Israel); Sackler School of Medicine, Tel Aviv University, Tel Aviv (Israel)

    2015-10-01

    Objective: To determine the effect of continuous positive airway pressure (CPAP) on tumor motion, lung volume, and dose to critical organs in patients receiving stereotactic body radiation therapy (SBRT) for lung tumors. Methods and Materials: After institutional review board approval in December 2013, patients with primary or secondary lung tumors referred for SBRT underwent 4-dimensional computed tomographic simulation twice: with free breathing and with CPAP. Tumor excursion was calculated by subtracting the vector of the greatest dimension of the gross tumor volume (GTV) from the internal target volume (ITV). Volumetric and dosimetric determinations were compared with the Wilcoxon signed-rank test. CPAP was used during treatment if judged beneficial. Results: CPAP was tolerated well in 10 of the 11 patients enrolled. Ten patients with 18 lesions were evaluated. The use of CPAP decreased tumor excursion by 0.5 ± 0.8 cm, 0.4 ± 0.7 cm, and 0.6 ± 0.8 cm in the superior–inferior, right–left, and anterior–posterior planes, respectively (P≤.02). Relative to free breathing, the mean ITV reduction was 27% (95% confidence interval [CI] 16%-39%, P<.001). CPAP significantly augmented lung volume, with a mean absolute increase of 915 ± 432 cm{sup 3} and a relative increase of 32% (95% CI 21%-42%, P=.003), contributing to a 22% relative reduction (95% CI 13%-32%, P=.001) in mean lung dose. The use of CPAP was also associated with a relative reduction in mean heart dose by 29% (95% CI 23%-36%, P=.001). Conclusion: In this pilot study, CPAP significantly reduced lung tumor motion compared with free breathing. The smaller ITV, the planning target volume (PTV), and the increase in total lung volume associated with CPAP contributed to a reduction in lung and heart dose. CPAP was well tolerated, reproducible, and simple to implement in the treatment room and should be evaluated further as a novel strategy for motion management in radiation therapy.

  18. Continuous Positive Airway Pressure for Motion Management in Stereotactic Body Radiation Therapy to the Lung: A Controlled Pilot Study

    International Nuclear Information System (INIS)

    Goldstein, Jeffrey D.; Lawrence, Yaacov R.; Appel, Sarit; Landau, Efrat; Ben-David, Merav A.; Rabin, Tatiana; Benayun, Maoz; Dubinski, Sergey; Weizman, Noam; Alezra, Dror; Gnessin, Hila; Goldstein, Adam M.; Baidun, Khader; Segel, Michael J.; Peled, Nir; Symon, Zvi

    2015-01-01

    Objective: To determine the effect of continuous positive airway pressure (CPAP) on tumor motion, lung volume, and dose to critical organs in patients receiving stereotactic body radiation therapy (SBRT) for lung tumors. Methods and Materials: After institutional review board approval in December 2013, patients with primary or secondary lung tumors referred for SBRT underwent 4-dimensional computed tomographic simulation twice: with free breathing and with CPAP. Tumor excursion was calculated by subtracting the vector of the greatest dimension of the gross tumor volume (GTV) from the internal target volume (ITV). Volumetric and dosimetric determinations were compared with the Wilcoxon signed-rank test. CPAP was used during treatment if judged beneficial. Results: CPAP was tolerated well in 10 of the 11 patients enrolled. Ten patients with 18 lesions were evaluated. The use of CPAP decreased tumor excursion by 0.5 ± 0.8 cm, 0.4 ± 0.7 cm, and 0.6 ± 0.8 cm in the superior–inferior, right–left, and anterior–posterior planes, respectively (P≤.02). Relative to free breathing, the mean ITV reduction was 27% (95% confidence interval [CI] 16%-39%, P<.001). CPAP significantly augmented lung volume, with a mean absolute increase of 915 ± 432 cm 3 and a relative increase of 32% (95% CI 21%-42%, P=.003), contributing to a 22% relative reduction (95% CI 13%-32%, P=.001) in mean lung dose. The use of CPAP was also associated with a relative reduction in mean heart dose by 29% (95% CI 23%-36%, P=.001). Conclusion: In this pilot study, CPAP significantly reduced lung tumor motion compared with free breathing. The smaller ITV, the planning target volume (PTV), and the increase in total lung volume associated with CPAP contributed to a reduction in lung and heart dose. CPAP was well tolerated, reproducible, and simple to implement in the treatment room and should be evaluated further as a novel strategy for motion management in radiation therapy

  19. Radial breathing vibration of double-walled carbon nanotubes subjected to pressure

    International Nuclear Information System (INIS)

    Lei, Xiao-Wen; Natsuki, Toshiaki; Shi, Jin-Xing; Ni, Qing-Qing

    2011-01-01

    A theoretical vibrational analysis of the radial breathing mode (RBM) of double-walled carbon nanotubes (DWCNTs) subjected to pressure is presented based on an elastic continuum model. The results agree with reported experimental results obtained under different conditions. Frequencies of the RBM in DWCNTs subjected to increasing pressure depend strongly on circumferential wave numbers, but weakly on the aspect ratio and axial half-wave numbers. For the inner and outer tubes of DWCNTs, the frequency of the RBM increases obviously as the pressure increases under different conditions. The range of variation is smaller for the inner tube than the outer tube. -- Highlights: → An elastic continuum model is used in the theoretical analysis of RBM of DWCNTs. → The RBM of DWCNTs subjected to pressure is analyzed. → Frequency of RBM depends on wave number and aspect ratio. → Frequencies of RBM in inner and outer tubes change in different trends and ranges.

  20. An Acute Bout of a Controlled Breathing Frequency Lowers Sympathetic Neural Outflow but not Blood Pressure in Healthy Normotensive Subjects

    Science.gov (United States)

    MCCLAIN, SHANNON L.; BROOKS, ALEXA M.; JARVIS, SARA S.

    2017-01-01

    Controlled or paced breathing is often used as a stress reduction technique but the impact on blood pressure (BP) and sympathetic outflow have not been consistently reported. The purpose of this study was to determine whether a controlled breathing (12 breaths/min, CB) rate would be similar to an individual’s spontaneous breathing (SB) rate. Secondly, would a CB rate of 12 breaths/min alter heart rate (HR), BP, and indices of muscle sympathetic nerve activity (MSNA). Twenty-one subjects (10 women, 11 men) performed two trials: SB, where the subject chose a comfortable breathing rate; and CB, where the subject breathed at a pace of 12 breaths/min. Each trial was 6 min during which respiratory waveforms, HR, BP (systolic, SBP; diastolic, DBP), and MSNA were recorded. During CB, the 6 min average breathing frequency (14±4 vs 12±1 breaths/min, P<0.05 for SB and CB, respectively), MSNA burst frequency (18±12 vs 14±10 bursts/min, P<0.01) and MSNA burst incidence (28±19 vs 21± 6 bursts/100 heart beats, P<0.01) were significantly lower than during SB. HR (66±9 vs 67±9 beats/min, P<0.05) was higher during CB. SBP (120±13 vs 121±15 mmHg, P=0.741), DBP (56±8 vs 57±9 mmHg, P=0.768), and MSNA total activity (166±94 vs 145±102 a.u./min, P=0.145) were not different between the breathing conditions. In conclusion, an acute reduction in breathing frequency such as that observed during CB elicited a decrease in indices of MSNA (burst frequency and incidence) with no change in BP. PMID:28344733

  1. A new device for administration of continuous positive airway pressure in preterm infants: comparison with a standard nasal CPAP continuous positive airway pressure system.

    Science.gov (United States)

    Trevisanuto, Daniele; Grazzina, Nicoletta; Doglioni, Nicoletta; Ferrarese, Paola; Marzari, Francesco; Zanardo, Vincenzo

    2005-06-01

    We compared the effectiveness of a new continuous positive airway pressure (CPAP) device (neonatal helmet CPAP) with a conventional nasal CPAP system in preterm neonates needing continuous distending pressure. Randomized, physiological, cross-over study in a tertiary referral, neonatal intensive care unit in a university teaching hospital. Twenty very low birth weight infants with a postnatal age greater than 24 h who were receiving nasal CPAP for apnea and/or mild respiratory distress were enrolled. CPAP delivered by neonatal helmet CPAP and nasal CPAP in random order for two subsequent 90-min periods. Were continuously measured the Neonatal Infant Pain Scale (NIPS) score, oxygen requirements, respiratory rate, heart rate, oxygen saturation, transcutaneous PO(2) (tcPO(2)) and PCO(2) (tcPCO(2)), blood pressure, and desaturations. NIPS scores were significantly lower when the infants were on the neonatal helmet CPAP than when they were on nasal CPAP (0.26+/-0.07 vs. 0.63+/-0.12). The other studied parameters did not differ between the two CPAP modes. The number of desaturations was reduced during the neonatal helmet CPAP treatment (18 vs. 32), although this difference was not significant. In this short-term physiological study the neonatal helmet CPAP appears to be as good as the golden standard for managing preterm infants needing continuous distending pressure, with enhanced tolerability. Further evaluation in a randomized clinical trial is needed to confirm these findings.

  2. Efficacy of the addition of positive airway pressure to conventional chest physiotherapy in resolution of pleural effusion after drainage: protocol for a randomised controlled trial.

    Science.gov (United States)

    da Conceição Dos Santos, Elinaldo; Lunardi, Adriana Claudia

    2015-04-01

    Chest drainage for pleural effusion can cause pain and changes in respiratory function. It can also increase the risk of pulmonary complications and impair functional ability, which may increase length of hospital stay and the associated costs. For these reasons, surgical and clinical strategies have been adopted to reduce the duration of chest drainage. To evaluate the efficacy of the addition of intermittent positive airway pressure applied by the Muller reanimator via a rubber facial mask versus conventional physiotherapy on the duration of chest drainage (primary objective), and its effect on the recovery of respiratory function, length of hospital stay and incidence of pulmonary complications (secondary objectives). Randomised, controlled trial. Inpatients with pleural effusion, aged over 18 years, who have had chest drainage in situ for drain will be a transudate output ≤ 200ml over 24hours and full lung expansion on chest radiography, as assessed by a blinded physician. Duration of chest drainage, length of hospital stay, and any pulmonary complications diagnosed during hospitalisation will be recorded. Intention to treat using: survival analysis for duration of chest drainage, and length of hospital stay; analysis of variance for chest-tube output, lung function and peripheral oxygen saturation; and chi-square tests for comparing the incidence of pulmonary complications between groups. Conventional chest physiotherapy and intermittent positive airway pressure breathing are widely indicated for people with pleural effusion and chest drains; however, no studies have evaluated the real benefit of this type of treatment. Our hypothesis is that optimised lung expansion achieved through the application of intermittent positive airway pressure will accelerate the reabsorption of pleural effusion, decrease the duration of chest drainage and respiratory system impairment, reduce the length of hospital stay, and reduce the incidence of pulmonary complications

  3. Continuous positive airway pressure for the treatment of obstructive sleep apnea.

    Science.gov (United States)

    Nurwidya, Fariz; Susanto, Agus Dwi; Juzar, Dafsah A; Kobayashi, Isao; Yunus, Faisal

    2016-01-01

    Obstructive sleep apnea (OSA) is a recurrent episode of partial or complete upper airway obstruction during sleep despite ongoing respiratory efforts and is implicated as the risk factor of cardiovascular disease. The OSA syndrome is typified by recurring partial or total occlusion of the pharynx, sleep fragmentation, episodes of gasping, and, eventually, daytime sleepiness. If it is left untreated, OSA syndrome can cause hypertension, coronary artery disease congestive heart disease, insulin resistance and death. In this review, we describe the pathogenesis and diagnosis of OSA. We also focused on the continuous positive airway pressure (CPAP) as the main therapy for OSA. CPAP has been shown to provide benefit for not only respiratory system, but also for cardiovascular system and metabolic system. Finally, we discussed briefly about the issue of adherence of using CPAP that could contribute to lower compliant in patient with OSA.

  4. Cerebral hemodynamics in patients with obstructive sleep apnea syndrome monitored with near-infrared spectroscopy (NIRS) during positive airways pressure (CPAP) therapy: a pilot study

    Science.gov (United States)

    Zhang, Zhongxing; Schneider, Maja; Laures, Marco; Fritschi, Ursula; Lehner, Isabella; Qi, Ming; Khatami, Ramin

    2014-03-01

    In obstructive sleep apnea syndrome (OSA) the periodic reduction or cessation of breathing due to narrowing or occlusion of the upper airway during sleep leads to daytime symptoms and increased cardiovascular risk, including stroke. The higher risk of stroke is related to the impairment in cerebral vascular autoregulation. Continuous positive airways pressure (CPAP) therapy at night is the most effective treatment for OSA. However, there is no suitable bedside monitoring method evaluating the treatment efficacy of CPAP therapy, especially to monitor the recovery of cerebral hemodynamics. NIRS is ideally suited for non-invasive monitoring the cerebral hemodynamics during sleep. In this study, we will for first time assess dynamic changes of cerebral hemodynamics during nocturnal CPAP therapy in 3 patients with OSA using NIRS. We found periodic oscillations in HbO2, HHb, tissue oxygenation index (TOI) and blood volume associated with periodic apnea events without CPAP in all OSA patients. These oscillations were gradually attenuated and finally eliminated with the stepwise increments of CPAP pressures. The oscillations were totally eliminated in blood volume earlier than in other hemodynamic parameters. These results suggested that 1) the cerebral hemodynamic oscillations induced by OSA events can effectively be attenuated by CPAP therapy, and 2) blood flow and blood volume recovered first during CPAP therapy, followed by the recovery of oxygen consumption. Our study suggested that NIRS is a useful tool to evaluate the efficacy of CPAP therapy in patients with OSA bedside and in real time.

  5. Pressure oscillation delivery to the lung: Computer simulation of neonatal breathing parameters.

    Science.gov (United States)

    Al-Jumaily, Ahmed M; Reddy, Prasika I; Bold, Geoff T; Pillow, J Jane

    2011-10-13

    Preterm newborn infants may develop respiratory distress syndrome (RDS) due to functional and structural immaturity. A lack of surfactant promotes collapse of alveolar regions and airways such that newborns with RDS are subject to increased inspiratory effort and non-homogeneous ventilation. Pressure oscillation has been incorporated into one form of RDS treatment; however, how far it reaches various parts of the lung is still questionable. Since in-vivo measurement is very difficult if not impossible, mathematical modeling may be used as one way of assessment. Whereas many models of the respiratory system have been developed for adults, the neonatal lung remains essentially ill-described in mathematical models. A mathematical model is developed, which represents the first few generations of the tracheo-bronchial tree and the 5 lobes that make up the premature ovine lung. The elements of the model are derived using the lumped parameter approach and formulated in Simulink™ within the Matlab™ environment. The respiratory parameters at the airway opening compare well with those measured from experiments. The model demonstrates the ability to predict pressures, flows and volumes in the alveolar regions of a premature ovine lung. Copyright © 2011 Elsevier Ltd. All rights reserved.

  6. Auto-trilevel versus bilevel positive airway pressure ventilation for hypercapnic overlap syndrome patients.

    Science.gov (United States)

    Su, Mei; Huai, De; Cao, Juan; Ning, Ding; Xue, Rong; Xu, Meijie; Huang, Mao; Zhang, Xilong

    2018-03-01

    Although bilevel positive airway pressure (Bilevel PAP) therapy is usually used for overlap syndrome (OS), there is still a portion of OS patients in whom Bilevel PAP therapy could not simultaneously eliminate residual apnea events and hypercapnia. The current study was expected to explore whether auto-trilevel positive airway pressure (auto-trilevel PAP) therapy with auto-adjusting end expiratory positive airway pressure (EEPAP) can serve as a better alternative for these patients. From January of 2014 to June of 2016, 32 hypercapnic OS patients with stable chronic obstructive pulmonary diseases (COPD) and moderate-to-severe obstructive sleep apnea syndrome (OSAS) were recruited. Three variable modes of positive airway pressure (PAP) from the ventilator (Prisma25ST, Weinmann Inc., Germany) were applicated for 8 h per night. We performed the design of each mode at each night with an interval of two nights with no PAP treatment as a washout period among different modes. In Bilevel-1 mode (Bilevel-1), the expiratory positive airway pressure (EPAP) delivered from Bilevel PAP was always set as the lowest PAP for abolishment of snoring. For each patient, the inspiratory positive airway pressure (IPAP) was constantly set the same as the minimal pressure for keeping end-tidal CO 2 (ETCO 2 ) ≤45 mmHg for all three modes. However, the EPAP issued by Bilevel PAP in Bilevel-2 mode (Bilevel-2) was kept 3 cmH 2 O higher than that in Bilevel-1. In auto-trilevel mode (auto-trilevel) with auto-trilevel PAP, the initial part of EPAP was fixed at the same PAP as that in Bilevel-1 while the EEPAP was automatically regulated to rise at a range of ≤4 cmH 2 O based on nasal airflow wave changes. Comparisons were made for parameters before and during or following treatment as well as among different PAP therapy modes. The following parameters were compared such as nocturnal apnea hypopnea index (AHI), minimal SpO 2 (minSpO 2 ), arousal index, sleep structure and efficiency

  7. Paradoxical reaction of blood pressure on sleep apnoea patients treated with Positive Airway Pressure

    Directory of Open Access Journals (Sweden)

    C. Chaves Loureiro

    2011-03-01

    Full Text Available Introduction: Obstructive Sleep Apnoea Syndrome (OSAS patients may develop hypertension and Positive Airway Pressure (PAP is an effective treatment in blood pressure (BP control. Objectives: Analyse a hypertensive OSAS population with unexpected BP rise after PAP usage and verify correlations between BP rise, either with OSAS severity index or nocturnal ventilatory support compliance. Methods: Descriptive, retrospective analysis of 30 patients with PAP treated OSA, for one year, on average, and with previous controlled hypertension, who developed a rise in BP, defined as augmentation of > 5 mmHg in systolic (SBP and/or diastolic BP (DBP, after PAP usage. Co-relational analysis of BP increase, with OSAS severity indexes and therapy compliance, using Pearson coefficient. Results: Of 508 consecutive patients followed in our Department, treated with nocturnal ventilatory support, 30 evolved with BP rise after initiating treatment (age 58 ± 10.8 years; Apnoea-Hypopnoea Index [AHI], 46.1 ± 18.68. After PAP usage, mean blood pressure (MBP, Systolic BP (SBP and Diastolic BP (DBP variation was 16 ± 15 mmHg, 20 ± 25 mmHg and 6 ± 19.4 mmHg, respectively. No patient showed significant BMI increase. Epworth Sleepiness Scale (ESS value decreased 8.9 ± 5.48 points. MBP, SBP and DBP variations were not correlated with P90/P95, residual AHI, leaks or PAP compliance. Conclusions: No specific characteristics were identified in the group who developed a rise in BP with PAP usage. No correlations were found between rises in BP and OSAS severity indexes or PAP compliance. Neither BMI nor variation in wakefulness status explained the rise in BP. Studies relate polymorphisms of b1-adrenoreceptors with different BP responses to ventilatory support. More studies are needed to clarify the cause of this paradoxical response. Resumo: Introdução: Doentes com síndrome de Apneia Obstrutiva do Sono (SAOS podem desenvolver hipertensão arterial (HTA sendo a

  8. Continuous Positive Airway Pressure Prevents Hypoxia in Dental Patient with Obstructive Sleep Apnea Syndrome under Intravenous Sedation.

    Science.gov (United States)

    Kasatkin, Anton A; Reshetnikov, Aleksei P; Urakov, Aleksandr L; Baimurzin, Dmitrii Y

    2017-01-01

    Use of sedation in patients with obstructive sleep apnea (OSA) in dentistry is limited. Hypoxia may develop during medication sleep in dental patients with OSA because of repetitive partial or complete obstruction of the upper airway. In this regard, anesthesiologists prefer not to give any sedative to surgical patients with OSA or support the use of general anesthesia due to good airway control. We report a case where we could successfully sedate a dental patient with OSA using intraoperative continuous positive airway pressure (CPAP) without hypoxia. Use of sedation and intraoperative CPAP in patients with OSA may be considered only if the effectiveness at home CPAP therapy is proven.

  9. Using an expiratory resistor, arterial pulse pressure variations predict fluid responsiveness during spontaneous breathing: an experimental porcine study.

    Science.gov (United States)

    Dahl, Michael K; Vistisen, Simon T; Koefoed-Nielsen, Jacob; Larsson, Anders

    2009-01-01

    Fluid responsiveness prediction is difficult in spontaneously breathing patients. Because the swings in intrathoracic pressure are minor during spontaneous breathing, dynamic parameters like pulse pressure variation (PPV) and systolic pressure variation (SPV) are usually small. We hypothesized that during spontaneous breathing, inspiratory and/or expiratory resistors could induce high arterial pressure variations at hypovolemia and low variations at normovolemia and hypervolemia. Furthermore, we hypothesized that SPV and PPV could predict fluid responsiveness under these conditions. Eight prone, anesthetized and spontaneously breathing pigs (20 to 25 kg) were subjected to a sequence of 30% hypovolemia, normovolemia, and 20% and 40% hypervolemia. At each volemic level, the pigs breathed in a randomized order either through an inspiratory and/or an expiratory threshold resistor (7.5 cmH2O) or only through the tracheal tube without any resistor. Hemodynamic and respiratory variables were measured during the breathing modes. Fluid responsiveness was defined as a 15% increase in stroke volume (DeltaSV) following fluid loading. Stroke volume was significantly lower at hypovolemia compared with normovolemia, but no differences were found between normovolemia and 20% or 40% hypervolemia. Compared with breathing through no resistor, SPV was magnified by all resistors at hypovolemia whereas there were no changes at normovolemia and hypervolemia. PPV was magnified by the inspiratory resistor and the combined inspiratory and expiratory resistor. Regression analysis of SPV or PPV versus DeltaSV showed the highest R2 (0.83 for SPV and 0.52 for PPV) when the expiratory resistor was applied. The corresponding sensitivity and specificity for prediction of fluid responsiveness were 100% and 100%, respectively, for SPV and 100% and 81%, respectively, for PPV. Inspiratory and/or expiratory threshold resistors magnified SPV and PPV in spontaneously breathing pigs during hypovolemia

  10. The effect of continuous positive airway pressure on blood pressure in patients with obstructive sleep apnea syndrome

    Directory of Open Access Journals (Sweden)

    Giorgiana Dediu

    2017-12-01

    Full Text Available Introduction. Obstructive sleep apnea syndrome (OSAS is a disease with increasing prevalence nowadays, being associated with multiple cardiovascular diseases, such as arterial hypertension. The objective of the study was to evaluate the effect of continuous positive airway pressure (CPAP on blood pressure values. Materials and methods. We performed a prospective interventional study on 52 patients with obstructive sleep apnea syndrome. The patients were divided into 2 groups: Group A (who received both pharmacological and CPAP treatment and Group B (who received only pharmacological treatment, and were followed up at 3 and 6 months. The statistical analysis was made with SPSS and Microsoft Excel. At the same time, using the surrogate marker –RDW, we tried to evaluate the persistence of systemic inflammation, knowing that OSAS is associated with inflammation. Results. The systolic blood pressure values decreased at 6 months in all OSAS patients who have used CPAP, including patients with normal values of blood pressure. At the same time, the lack of OSAS treatment led to increased values of blood pressure by approximately 10 mmHg. We noticed a link between RDW, age and blood pressure values, respectively the increase of RDW and age may result in an increase in blood pressure. Conclusions. The OSAS treatment can decrease the blood pressure values. A higher RDW may be considered a negative prognostic factor for these patients, reflecting the role of systemic inflammation in the appearance of cardiovascular disorders.

  11. Clinical predictors of central sleep apnea evoked by positive airway pressure titration.

    Science.gov (United States)

    Moro, Marilyn; Gannon, Karen; Lovell, Kathy; Merlino, Margaret; Mojica, James; Bianchi, Matt T

    2016-01-01

    Treatment-emergent central sleep apnea (TECSA), also called complex apnea, occurs in 5%-15% of sleep apnea patients during positive airway pressure (PAP) therapy, but the clinical predictors are not well understood. The goal of this study was to explore possible predictors in a clinical sleep laboratory cohort, which may highlight those at risk during clinical management. We retrospectively analyzed 728 patients who underwent PAP titration (n=422 split-night; n=306 two-night). Demographics and self-reported medical comorbidities, medications, and behaviors as well as standard physiological parameters from the polysomnography (PSG) data were analyzed. We used regression analysis to assess predictors of binary presence or absence of central apnea index (CAI) ≥5 during split-night PSG (SN-PSG) versus full-night PSG (FN-PSG) titrations. CAI ≥5 was present in 24.2% of SN-PSG and 11.4% of FN-PSG patients during titration. Male sex, maximum continuous positive airway pressure, and use of bilevel positive airway pressure were predictors of TECSA, and rapid eye movement dominance was a negative predictor, for both SN-PSG and FN-PSG patients. Self-reported narcotics were a positive predictor of TECSA, and the time spent in stage N2 sleep was a negative predictor only for SN-PSG patients. Self-reported history of stroke and the CAI during the diagnostic recording predicted TECSA only for FN-PSG patients. Clinical predictors of treatment-evoked central apnea spanned demographic, medical history, sleep physiology, and titration factors. Improved predictive models may be increasingly important as diagnostic and therapeutic modalities move away from the laboratory setting, even as PSG remains the gold standard for characterizing primary central apnea and TECSA.

  12. Bilateral diaphragmatic paralysis after cardiac surgery: ventilatory assistance by nasal mask continuous positive airway pressure.

    Science.gov (United States)

    Hoch, B; Zschocke, A; Barth, H; Leonhardt, A

    2001-01-01

    The case of an 8-month-old boy with bilateral diaphragmatic paralysis after surgical reoperation for congenital heart disease is presented. In order to avoid repeated intubation and long-term mechanical ventilation or tracheotomy, we used nasal mask continuous positive airway pressure (CPAP) as an alternative method for assisted ventilation. Within 24 hours the boy accepted the nasal mask and symptoms such as dyspnea and sweating disappeared. Respiratory movements became regular and oxygen saturation increased. Nasal mask CPAP may serve as an alternative treatment of bilateral diaphragmatic paralysis in infants, thereby avoiding tracheotomy or long-term mechanical ventilation.

  13. Oral continuous positive airway pressure (CPAP) following nasal injury in a preterm infant.

    Science.gov (United States)

    Carlisle, H R; Kamlin, C O F; Owen, L S; Davis, P G; Morley, C J

    2010-03-01

    Non-invasive respiratory support is increasingly popular but is associated with complications including nasal trauma. The present report describes a novel method of oral continuous positive airway pressure (CPAP) delivery in an extremely premature infant with severe nasal septum erosion. The distal end of a cut down endotracheal tube was passed through a small hole made in the teat of a dummy (infant pacifier) and sutured in place. The dummy was secured in the infant's mouth and CPAP was delivered to the pharynx. The device was well tolerated and the infant was successfully managed using this technique for 48 days, avoiding endotracheal intubation and ventilation.

  14. Predicting uptake of continuous positive airway pressure (CPAP) therapy in obstructive sleep apnoea (OSA)

    DEFF Research Database (Denmark)

    Skinner, Timothy; McNeil, Lindsay; Olaithe, Michelle

    2013-01-01

    diagnosed with OSA. Epworth sleepiness scale (ESS), Fatigue Severity Scale, Depression Anxiety Stress Scale and Illness Perception Questionnaire-Revised (IPQ-R) were administered at time of sleep study. These, patient demographics and sleep study variables were used to determine factors predicting patient......Purpose: Obstructive sleep apnoea (OSA) is a common disorder, for which continuous positive airway pressure (CPAP) therapy is a standard treatment. Despite its well-established efficacy, many patients choose not to initiate CPAP treatment. The present study investigated the degree to which...

  15. Extubation success in premature infants with respiratory distress syndrome treated with bi-level nasal continuous positive airway pressure versus nasal intermittent positive pressure ventilation.

    Science.gov (United States)

    Thomas, Patricia E; LeFlore, Judy

    2013-01-01

    Infants born prematurely with respiratory distress syndrome are at high risk for complications from mechanical ventilation. Strategies are needed to minimize their days on the ventilator. The purpose of this study was to compare extubation success rates in infants treated with 2 different types of continuous positive airway pressure devices. A retrospective cohort study design was used. Data were retrieved from electronic medical records for patients in a large, metropolitan, level III neonatal intensive care unit. A sample of 194 premature infants with respiratory distress syndrome was selected, 124 of whom were treated with nasal intermittent positive pressure ventilation and 70 with bi-level variable flow nasal continuous positive airway pressure (bi-level nasal continuous positive airway pressure). Infants in both groups had high extubation success rates (79% of nasal intermittent positive pressure ventilation group and 77% of bi-level nasal continuous positive airway pressure group). Although infants in the bi-level nasal continuous positive airway pressure group were extubated sooner, there was no difference in duration of oxygen therapy between the 2 groups. Promoting early extubation and extubation success is a vital strategy to reduce complications of mechanical ventilation that adversely affect premature infants with respiratory distress syndrome.

  16. Positive expiratory pressure therapy versus other airway clearance techniques for bronchiectasis.

    Science.gov (United States)

    Lee, Annemarie L; Burge, Angela T; Holland, Anne E

    2017-09-27

    People with bronchiectasis experience chronic cough and sputum production and require the prescription of airway clearance techniques (ACTs). A common type of ACT prescribed is positive expiratory pressure (PEP) therapy. A previous review has suggested that ACTs including PEP therapy are beneficial compared to no treatment in people with bronchiectasis. However, the efficacy of PEP therapy in a stable clinical state or during an acute exacerbation compared to other ACTs in bronchiectasis is unknown. The primary aim of this review was to determine the effects of PEP therapy compared with other ACTs on health-related quality of life (HRQOL), rate of acute exacerbations, and incidence of hospitalisation in individuals with stable or an acute exacerbation of bronchiectasis.Secondary aims included determining the effects of PEP therapy upon physiological outcomes and clinical signs and symptoms compared with other ACTs in individuals with stable or an acute exacerbation of bronchiectasis. We searched the Cochrane Airways Group Specialised Register of Trials, PEDro and clinical trials registries from inception to February 2017 and we handsearched relevant journals. Randomised controlled parallel and cross-over trials that compared PEP therapy versus other ACTs in participants with bronchiectasis. We used standard methodological procedures as outlined by Cochrane. Nine studies involving 213 participants met the inclusion criteria, of which seven were cross-over in design. All studies included adults with bronchiectasis, with eight including participants in a stable clinical state and one including participants experiencing an acute exacerbation. Eight studies used oscillatory PEP therapy, using either a Flutter or Acapella device and one study used Minimal PEP therapy. The comparison intervention differed between studies. The methodological quality of studies was poor, with cross-over studies including suboptimal or no washout period, and a lack of blinding of

  17. Choosing an Oronasal Mask to Deliver Continuous Positive Airway Pressure May Cause More Upper Airway Obstruction or Lead to Higher Continuous Positive Airway Pressure Requirements than a Nasal Mask in Some Patients: A Case Series.

    Science.gov (United States)

    Ng, Justin R; Aiyappan, Vinod; Mercer, Jeremy; Catcheside, Peter G; Chai-Coetzer, Ching Li; McEvoy, R Doug; Antic, Nick

    2016-09-15

    The choice of mask interface used with continuous positive airway pressure (CPAP) therapy can affect the control of upper airway obstruction (UAO) in obstructive sleep apnea (OSA). We describe a case series of four patients with paradoxical worsening of UAO with an oronasal mask and the effect of changing to a nasal mask. We retrospectively reviewed the case histories of 4 patients and recorded patient demographics, in-laboratory and ambulatory CPAP titration data, CPAP therapy data, type of mask interface used and potential confounding factors. The 4 cases (mean ± SD: age = 59 ± 16 y; BMI = 30.5 ± 4.5 kg/m(2)) had a high residual apnoea-hypopnea index (AHI) (43 ± 14.2 events/h) and high CPAP pressure requirements (14.9 ± 6.6 cmH2O) with an oronasal mask. Changing to a nasal mask allowed adequate control of UAO with a significant reduction in the average residual AHI (3.1 ± 1.5 events/h). In two of the four cases, it was demonstrated that control of UAO was obtained at a much lower CPAP pressure compared to the oronasal mask (Case one = 17.5 cmH2O vs 12cmH2O; Case two = 17.9 cmH2O vs 7.8 cmH2O). Other potential confounding factors were unchanged. There are various physiological observations that may explain these findings but it is uncertain which individuals are susceptible to these mechanisms. If patients have OSA incompletely controlled by CPAP with evidence of residual UAO and/or are requiring surprisingly high CPAP pressure to control OSA with an oronasal mask, the choice of mask should be reviewed and consideration be given to a trial of a nasal mask. A commentary on this article appears in this issue on page 1209. © 2016 American Academy of Sleep Medicine.

  18. Experimental intra-abdominal hypertension influences airway pressure limits for lung protective mechanical ventilation.

    Science.gov (United States)

    Cortes-Puentes, Gustavo A; Cortes-Puentes, Luis A; Adams, Alexander B; Anderson, Christopher P; Marini, John J; Dries, David J

    2013-06-01

    Intra-abdominal hypertension (IAH) and abdominal compartment syndrome (ACS) may complicate monitoring of pulmonary mechanics owing to their impact on the respiratory system. However, recommendations for mechanical ventilation of patients with IAH/ACS and the interpretation of thoracoabdominal interactions remain unclear. Our study aimed to characterize the influence of elevated intra-abdominal pressure (IAP) and positive end-expiratory pressure (PEEP) on airway plateau pressure (PPLAT) and bladder pressure (PBLAD). Nine deeply anesthetized swine were mechanically ventilated via tracheostomy: volume-controlled mode at tidal volume (VT) of 10 mL/kg, frequency of 15, inspiratory-expiratory ratio of 1:2, and PEEP of 1 and 10 cm H2O (PEEP1 and PEEP10, respectively). A tracheostomy tube was placed in the peritoneal cavity, and IAP levels of 5, 10, 15, 20, and 25 mm Hg were applied, using a continuous positive airway pressure system. At each IAP level, PBLAD and airway pressure measurements were performed during both PEEP1 and PEEP10. PBLAD increased as experimental IAP rose (y = 0.83x + 0.5; R = 0.98; p < 0.001 at PEEP1). Minimal underestimation of IAP by PBLAD was observed (-2.5 ± 0.8 mm Hg at an IAP of 10-25 mm Hg). Applying PEEP10 did not significantly affect the correlation between experimental IAP and PBLAD. Approximately 50% of the PBLAD (in cm H2O) was reflected by changes in PPLAT, regardless of the PEEP level applied. Increasing IAP did not influence hemodynamics at any level of IAP generated. With minimal underestimation, PBLAD measurements closely correlated with experimentally regulated IAP, independent of the PEEP level applied. For each PEEP level applied, a constant proportion (approximately 50%) of measured PBLAD (in cm H2O) was reflected in PPLAT. A higher safety threshold for PPLAT should be considered in the setting of IAH/ACS as the clinician considers changes in VT. A strategy of reducing VT to cap PPLAT at widely recommended values may not be

  19. Effect of a patient engagement tool on positive airway pressure adherence: analysis of a German healthcare provider database.

    Science.gov (United States)

    Woehrle, Holger; Arzt, Michael; Graml, Andrea; Fietze, Ingo; Young, Peter; Teschler, Helmut; Ficker, Joachim H

    2018-01-01

    This study investigated the addition of a real-time feedback patient engagement tool on positive airway pressure (PAP) adherence when added to a proactive telemedicine strategy. Data from a German healthcare provider (ResMed Healthcare Germany) were retrospectively analyzed. Patients who first started PAP therapy between 1 September 2009 and 30 April 2014, and were managed using telemedicine (AirView™; proactive care) or telemedicine + patient engagement tool (AirView™ + myAir™; patient engagement) were eligible. Patient demographics, therapy start date, sleep-disordered breathing indices, device usage hours, and therapy termination rate were obtained and compared between the two groups. The first 500 patients managed by telemedicine-guided care and a patient engagement tool were matched with 500 patients managed by telemedicine-guided care only. The proportion of nights with device usage ≥4 h was 77 ± 25% in the patient engagement group versus 63 ± 32% in the proactive care group (p < 0.001). Therapy termination occurred less often in the patient engagement group (p < 0.001). The apnea-hypopnea index was similar in the two groups, but leak was significantly lower in the patient engagement versus proactive care group (2.7 ± 4.0 vs 4.1 ± 5.3 L/min; p < 0.001). Addition of a patient engagement tool to telemonitoring-guided proactive care was associated with higher device usage and lower leak. This suggests that addition of an engagement tool may help improve PAP therapy adherence and reduce mask leak. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  20. Boussignac continuous positive airway pressure for the management of acute cardiogenic pulmonary edema: prospective study with a retrospective control group

    Directory of Open Access Journals (Sweden)

    Aarts Leon PHJ

    2007-12-01

    Full Text Available Abstract Background Continuous positive airway pressure (CPAP treatment for acute cardiogenic pulmonary edema can have important benefits in acute cardiac care. However, coronary care units are usually not equipped and their personnel not adequately trained for applying CPAP with mechanical ventilators. Therefore we investigated in the coronary care unit setting the feasibility and outcome of the simple Boussignac mask-CPAP (BCPAP system that does not need a mechanical ventilator. Methods BCPAP was introduced in a coronary care unit where staff had no CPAP experience. All consecutive patients transported to our hospital with acute cardiogenic pulmonary edema, a respiratory rate > 25 breaths/min and a peripheral arterial oxygen saturation of Results During the 2-year prospective BCPAP study period 108 patients were admitted with acute cardiogenic pulmonary edema. Eighty-four of these patients (78% were treated at the coronary care unit of which 66 (61% were treated with BCPAP. During the control period 66 patients were admitted over a 1-year period of whom 31 (47% needed respiratory support in the intensive care unit. BCPAP treatment was associated with a reduced hospital length of stay and fewer transfers to the intensive care unit for intubation and mechanical ventilation. Overall estimated savings of approximately € 3,800 per patient were achieved with the BCPAP strategy compared to conventional treatment. Conclusion At the coronary care unit, BCPAP was feasible, medically effective, and cost-effective in the treatment of acute cardiogenic pulmonary edema. Endpoints included mortality, coronary care unit and hospital length of stay, need of ventilatory support, and cost (savings.

  1. Effectiveness and safety of a prehospital program of continuous positive airway pressure (CPAP) in an urban setting.

    Science.gov (United States)

    Willmore, Andrew; Dionne, Richard; Maloney, Justin; Ouston, Ed; Stiell, Ian

    2015-11-01

    Continuous positive airway pressure (CPAP) is commonly used in the treatment of acute cardiogenic pulmonary edema (ACPE) and acute exacerbations of chronic obstructive pulmonary disease (AECOPD). In-hospital evidence is robust: CPAP has been shown to improve respiratory status and to reduce intubation rates. There is less evidence on prehospital CPAP, although the emergency medical services (EMS) adoption of this modality is increasing. The objectives of this study were to 1) measure the effectiveness of prehospital CPAP on morbidity, mortality, and transport times; and 2) audit the selection of patients by medics for appropriateness and safety. We conducted a before-and-after study from August 1 to October 31 in 2010 and 2011, before and after the implementation of prehospital CPAP in a city of one million people with large rural areas. Medics were trained to apply CPAP to patients with respiratory distress and a presumed diagnosis of ACPE or AECOPD. Charts were selected using the search criteria of the chief complaint of shortness of breath, emergent transport to hospital, and any patients receiving CPAP in the field. Data extracted from ambulance call reports and hospital records were analysed with appropriate univariate statistics. A total of 373 patients enrolled (186 pre-non-invasive ventilation [NIV] and 187 post-NIV), mean age 71.5 years, female 51.4%, and final diagnoses of ACPE 18.9%, AECOPD 21.9%. In the post group of 84 patients meeting NIV criteria, 41.6% received NIV; and of 102 patients not meeting the criteria, 5.2% received NIV. There were 12 minor adverse events in 36 applications (33.3%) as per protocol. Comparing post versus pre, there were higher rates of emergency department (ED) NIV (20.0% v. 13.4%, pCPAP in our prehospital setting with respect to morbidity, mortality, and length of stay. EMS must exercise caution in making the decision to invest in the equipment and training required to implement prehospital CPAP.

  2. Grain Entrapment Pressure on the Torso: Can You Breathe while Buried in Grain?

    Science.gov (United States)

    Moore, Kevin G; Jones, Carol L

    2017-04-26

    The pressure applied to the chest and back of a simulated grain entrapment victim was measured. Pressure sensors were attached to the chest and back of a manikin that was buried in grain in the vertical position. Measurements were made in four grain types at four grain depths ranging from the top of the manikin's shoulders to 0.61 m (24 in.) over the head. The pressure ranged from 1.6 to 4.0 kPa (0.23 to 0.57 psi). Based on available physiological information, this amount of pressure is unlikely to limit the respiration of an otherwise healthy adult male victim. However, other factors, such as the victim's age, gender, and body position in the grain, may influence respiration. The aspiration of grain appears to be the most likely asphyxiation risk during grain bin entrapment. Entering a grain storage bin is inherently dangerous, and Occupational Safety and Health Administration (OSHA) guidelines for permit-required confined spaces and grain handling facilities must be followed. Due to the risk of grain aspiration during engulfment, the development of safety equipment that could help protect the airway of a victim should be investigated. Copyright© by the American Society of Agricultural Engineers.

  3. The effects of progressive muscular relaxation and breathing control technique on blood pressure during pregnancy

    Directory of Open Access Journals (Sweden)

    Mahboobeh Aalami

    2016-01-01

    Full Text Available Background: Hypertensive disorders in pregnancy are the main cause of maternal and fetal mortality; however, they have no definite effective treatment. The researchers aimed to study the effects of progressive muscular relaxation and breathing control technique on blood pressure (BP during pregnancy. Materials and Methods: This three-group clinical trial was conducted in Mashhad health centers and governmental hospitals. Sixty pregnant (after 20 weeks of gestational age women with systolic BP ≥ 135 mmHg or diastolic BP ≥ 85 mmHg were assigned to three groups. Progressive muscular relaxation and breathing control exercises were administered to the two experimental groups once a week in person and in the rest of the days by instructions given on a CD for 4 weeks. BP was checked before and after the interventions. BP was measured before and after 15 min subjects' waiting without any especial intervention in the control group. Results: After 4 weeks of intervention, the systolic (by a mean of 131.3 to 117.2, P = 0.001 and by a mean of 131.05 to 120.5, P = 0.004, respectively and diastolic (by a mean of 79.2 to 72.3, P = 0.001 and by a mean of 80.1 to 76.5, P = 0.047, respectively BPs were significantly decreased in progressive muscular relaxation and breathing control groups, but they were not statistically significant in the control group. Conclusions: The interventions were effective on decreasing systolic and diastolic BP to normal range after 4 weeks in both the groups. The effects of both the interventions were more obvious on systolic BP compared to diastolic BP.

  4. Efficacy of daytime continuous positive airway pressure titration in severe obstructive sleep apnoea.

    Science.gov (United States)

    Rudkowski, J C; Verschelden, P; Kimoff, R J

    2001-09-01

    The aim of this study was to evaluate manual nasal continuous positive airway pressure (nCPAP) titration during daytime polysomnography compared with conventional overnight titration for patients with severe obstructive sleep apnoea. Thirty-two patients who underwent daytime titration were retrospectively matched (for age, sex, body mass index and apnoea/hypopnoea index (AHI)) to a group titrated overnight during the same period. Successful titration was defined as the identification of the nCPAP level (effective nCPAP (Peff)) required to eliminate respiratory events during all sleep stages. After 3 months of therapy on nCPAP at Peff, nCPAP utilization history was obtained and a group of patients underwent a repeat polysomnogram (PSG) and completed a follow-up Epworth Sleepiness Scale (ESS) score. Initial titration was successful in 91% of daytime patients and 91% of overnight patients. The success of daytime titration was not related to diagnostic AHI or ESS score. Subjective nCPAP utilization was statistically similar in both groups. On the follow-up PSG, there were no significant differences between daytime (n=11) and overnight (n=11) patients in measures of sleep quality or respiratory disturbance. Both groups demonstrated similar and significant improvements in ESS score. These findings suggest that the effective nasal continuous positive airway pressure can be accurately established during daytime titration in a substantial proportion of severe, symptomatic obstructive sleep apnoea patients.

  5. Hyperinflation and intrinsic positive end-expiratory pressure: less room to breathe.

    Science.gov (United States)

    Krieger, Bruce P

    2009-01-01

    Clinically, the symptoms and limited exercise capabilities of patients with chronic obstructive pulmonary disease (COPD) correlate better with changes in lung volumes than with airflow measurements. The realization of the clinical importance of hyperinflation has been overshadowed for decades by the use of forced expiratory volume during 1 s (FEV(1)) and the ratio of the FEV(1) to the forced expiratory vital capacity (FEV(1)/FVC) to categorize the severity and progression of COPD. Hyperinflation is defined as an elevation in the end-expiratory lung volume or functional residual capacity. When severe hyperinflation encroaches upon inspiratory capacity and limits vital capacity, it results in elevated intrinsic positive end-expiratory pressure (PEEPi) that places the diaphragm at a mechanical disadvantage and increases the work of breathing. Severe hyperinflation is the major physiologic cause of the resulting hypercarbic respiratory failure and patients' inability to transition (i.e. wean) from mechanical ventilatory support to spontaneous breathing. This paper reviews the basic physiologic principles of hyperinflation and its clinical manifestations as demonstrated by PEEPi. Also reviewed are the adverse effects of hyperinflation and PEEPi in critically ill patients with COPD, and methods for minimizing or counterbalancing these effects. Copyright 2009 S. Karger AG, Basel.

  6. [Comparison of different continuous positive airway pressure titration methods for obstructive sleep apnea hypopnea syndrome].

    Science.gov (United States)

    Li, Jingjing; Ye, Jingying; Zhang, Peng; Kang, Dan; Cao, Xin; Zhang, Yuhuan; Ding, Xiu; Zheng, Li; Li, Hongguang; Bian, Qiuli

    2014-10-01

    To explore whether there were differences between the results of automatic titration and the results of manual titration for positive airway pressure treatment in patients with obstructive sleep apnea hypopnea syndrome (OSAHS) and its influencing factors, the results might provide a theoretical basis for the rational use of two pressure titration methods. Sixty one patients with OSAHS were included in this study. All patients underwent a manual titration and an automatic titration within one week. The clinical informations, polysomnography data, and the results of both two titration of all patients were obtained for analysis. The overall apnea/hypopnea index was (63.1 ± 17.7)/h, with a range of 14.9/h to 110.4/h. The treatment pressure of manual titration was (8.4 ± 2.1) cmH(2)O, which was significantly lower than the treatment pressure of automatic titration, (11.5 ± 2.7) cmH(2)O (t = -9.797, P titration and manual titration), it was found that the pressure of automatic titration was significantly higher in patients with a ΔP > 3 cmH(2)O than in patients with a ΔP ≤ 3 cmH(2)O, which was (13.3 ± 2.3) cmH(2)O vs (10.0 ± 2.0) cmH(2)O (t = -6.159, P titration between these two groups, which was (8.6 ± 2.4) cmH(2)O vs (8.3 ± 2.0)cmH(2)O (P > 0.05). There was no significant difference in age, body mass index, neck circumference, abdomen circumference, apnea hypopnea index, and arterial oxygen saturation between these two groups. The treatment pressure of automatic titration is usually higher than that of manual titration. For patients with a high treatment pressure which is derived from automatic titration, a suggestion about manual titration could be given to decrease the potential treatment pressure of continuous positive airway pressure, which may be helpful in improving the comfortableness and the compliance of this treatment.

  7. Nasal continuous positive airways pressure immediately after extubation for preventing morbidity in preterm infants.

    Science.gov (United States)

    Davis, P G; Henderson-Smart, D J

    2003-01-01

    Preterm infants being extubated following a period of intermittent positive pressure ventilation via an endotracheal tube are at risk of developing respiratory failure as a result of apnea, respiratory acidosis and hypoxia. Nasal continuous positive airway pressure appears to stabilise the upper airway, improve lung function and reduce apnea and may therefore have a role in facilitating extubation in this population. In preterm infants having their endotracheal tube removed following a period of intermittent positive pressure ventilation (IPPV), does management with nasal continuous positive airways pressure (NCPAP) lead to an increased proportion remaining free of additional ventilatory support, compared to extubation directly to headbox oxygen? Searches were made of the Oxford Database of Perinatal Trials, MEDLINE up to November 2002, Cochrane Controlled Trials Register (The Cochrane Library, Issue 4, 2002), previous reviews including cross references, abstracts of conferences and symposia proceedings, expert informants and journal handsearching mainly in the English language. All trials utilising random or quasi-random patient allocation, in which NCPAP (delivered by any method) was compared with headbox oxygen for post-extubation care were included. Methodological quality was assessed independently by the two authors. Data were extracted independently by the two authors. Prespecified subgroup analysis to determine the impact of different levels of NCPAP, differences in duration of IPPV and use of aminophylline were also performed using the same package. Data were analysed using relative risk (RR), risk difference (RD) and number needed to treat (NNT). Nasal CPAP, when applied to preterm infants being extubated following IPPV, reduces the incidence of adverse clinical events (apnea, respiratory acidosis and increased oxygen requirements) indicating the need for additional ventilatory support [RR 0.62 (0.49, 0.77), RD -0.17 (-0.24,-0.10), NNT 6 (4,10)]. nasal

  8. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... a Family Parenting as an Adult With CF Treatments and Therapies People with cystic fibrosis are living ... to specialized CF care and a range of treatment options. Airway Clearance Active Cycle of Breathing Technique ...

  9. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... a Family Parenting as an Adult With CF Treatments and Therapies People with cystic fibrosis are living longer and ... to specialized CF care and a range of treatment options. Airway Clearance Active Cycle of Breathing Technique ...

  10. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... decisions about your health care. CF Genetics: The Basics CF Mutations Video Series Find Out More About ... of Breathing Technique Airway Clearance Techniques Autogenic Drainage Basics of Lung Care Chest Physical Therapy Coughing and ...

  11. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... many challenges, including medical, social, and financial. By learning more about how you can manage your disease every day, you can ultimately help find a ... Cycle of Breathing Technique Airway Clearance Techniques Autogenic ...

  12. High altitude pulmonary edema and exercise at 4,400 meters on Mount McKinley. Effect of expiratory positive airway pressure.

    Science.gov (United States)

    Schoene, R B; Roach, R C; Hackett, P H; Harrison, G; Mills, W J

    1985-03-01

    Breathing against positive expiratory pressure has been used to improve gas exchange in many forms of pulmonary edema, and forced expiration against resistance during exercise has been advocated for climbing at high altitude as a method to optimize performance. To evaluate the effect of expiratory positive airway pressure (EPAP) on climbers with high altitude pulmonary edema (HAPE) and on exercise at high altitude, we studied four climbers with HAPE at rest and 13 healthy climbers during exercise on a bicycle ergometer at 4400 m. We measured minute ventilation (VI, L/min), arterial oxygen saturation (SaO2 percent), end-tidal carbon dioxide (PACO2, mm Hg), respiratory rate (RR), and heart rate (HR) during the last minute of a five minute interval at rest in the climbers with HAPE, and at rest, 300, and 600 kpm/minute workloads on a bicycle ergometer in the healthy subjects. The HAPE subjects demonstrated an increased SaO2 percent, no change in HR or VI, and a decrease in RR on EPAP as compared to control. In normal subjects, SaO2 percent, VI, and heart rate were significantly higher on EPAP 10 cm H2O than 0 cm H2O control (p less than 0.01, 0.01, and 0.05, respectively). The RR and PaCO2 were not significantly different. In summary, EPAP improves gas exchange in HAPE subjects at rest. The EPAP in normal subjects at high altitude resulted in a higher SaO2 percent at the expense of a higher VI and higher HR. These results suggest that the work of breathing is higher and the stroke volume lower on EPAP. The positive pressure mask may be an effective temporizing measure for victims of HAPE who cannot immediately go to a lower altitude.

  13. Comparison of quiet breathing and controlled ventilation in the high-resolution CT assessment of airway disease in infants with cystic fibrosis

    Energy Technology Data Exchange (ETDEWEB)

    Long, Frederick R.; Adler, Brent H. [Children' s Radiological Institute, Children' s Hospital, Columbus, OH (United States); Williams, Roger S. [Christiana Hospitals, Department of Radiology, Newark, DE (United States); Castile, Robert G. [Children' s Hospital, Section of Pulmonary Medicine, Department of Pediatrics, Columbus, OH (United States)

    2005-11-01

    Respiratory motion and low lung volumes limit the quality of HRCT examinations in infants and young children. To assess the effects of respiratory motion and lung inflation on the ability to diagnose airway abnormalities and air trapping (AT) using HRCT in infants with cystic fibrosis (CF). HRCT images of the lungs were obtained at four anatomical levels in 16 sedated children (age 2.4{+-}1.1 years, mean{+-}SD) with CF using controlled ventilation at full lung inflation (CVCT-I), at resting end exhalation (CVCT-E), and during quiet breathing (CT-B). Two blinded reviewers independently and then by consensus scored all images for the presence or absence of bronchiectasis (BE), bronchial wall thickening (BWT), and AT. Of the 64 images evaluated, BE was identified in 19 (30%) of the CVCT-I images compared to 6 (9%) of the CVCT-E images (P=0.006) and 4 (6%) of the CT-B images (P=0.044). AT was seen in 29 (45%) of the CVCT-E images compared to 14 (22%) of the CVCT-I images (P=0.012) and 12 (19%) of the CT-B images (P=0.012). There were no significant differences in the detection of BWT among the three methods. Summary: In infants with CF, fully inflating the lung improved the ability to diagnose early BE, and obtaining motion-free images at end exhalation enhanced the detection of AT. (orig.)

  14. Clinical predictors of central sleep apnea evoked by positive airway pressure titration

    Directory of Open Access Journals (Sweden)

    Moro M

    2016-07-01

    Full Text Available Marilyn Moro,1 Karen Gannon,1 Kathy Lovell,1 Margaret Merlino,1 James Mojica,2 Matt T Bianchi,1,3 1Neurology Department, 2Pulmonary and Critical Care Medicine, Massachusetts General Hospital, Boston, MA, USA; 3Division of Sleep Medicine, Harvard Medical School, Boston, MA, USA Purpose: Treatment-emergent central sleep apnea (TECSA, also called complex apnea, occurs in 5%–15% of sleep apnea patients during positive airway pressure (PAP therapy, but the clinical predictors are not well understood. The goal of this study was to explore possible predictors in a clinical sleep laboratory cohort, which may highlight those at risk during clinical management.Methods: We retrospectively analyzed 728 patients who underwent PAP titration (n=422 split night; n=306 two-night. Demographics and self-reported medical comorbidities, medications, and behaviors as well as standard physiological parameters from the polysomnography (PSG data were analyzed. We used regression analysis to assess predictors of binary presence or absence of central apnea index (CAI ≥5 during split PSG (SN-PSG versus full-night PSG (FN-PSG titrations.Results: CAI ≥5 was present in 24.2% of SN-PSG and 11.4% of FN-PSG patients during titration. Male sex, maximum continuous positive airway pressure, and use of bilevel positive airway pressure were predictors of TECSA, and rapid eye movement dominance was a negative predictor, for both SN-PSG and FN-PSG patients. Self-reported narcotics were a positive predictor of TECSA, and the time spent in stage N2 sleep was a negative predictor only for SN-PSG patients. Self-reported history of stroke and the CAI during the diagnostic recording predicted TECSA only for FN-PSG patients.Conclusion: Clinical predictors of treatment-evoked central apnea spanned demographic, medical history, sleep physiology, and titration factors. Improved predictive models may be increasingly important as diagnostic and therapeutic modalities move away from the

  15. Impact of Polysomnographic Parameters on Continuous Positive Airway Pressure in Patient with Obstructive Sleep Apnea in 2012

    Directory of Open Access Journals (Sweden)

    Abolfazl Mozafari

    2014-06-01

    Full Text Available Background & objectives : O bstructive sleep apnea is a preventable and prevalent major health hazard with serious health consequences including excessive daytime sleepiness, cognitive disturbances, depression, cardiovascular diseases and hypertension. Obstructive sleep apnea is a disorder affecting 2 to 4% of the adult population. The continuous positive airway pressur e (CPAP i s the most efficacious therapy and is often the first option for these patients. The pressure titration during laboratory polysomnography is required for treatment by CPAP.   Methods: The patients with obstructive sleep apnea requiring continuous positive airway pressure treatment were selected . CPAP titration was done according to American Academy of Sleep Medicine protocol. Comparison among continuous positive airway pressure with polysomnographic parameters was performed and analyzed with Pearson correlation coefficient. For analysis of qualitative parameters, we used chi-square and then checked with SPSS version 18 software.   Results: From 125 patients with obstructive sleep apnea, there were 112 cases with inclusion criteria. Mean age of participants was 55.07 ± 12, male frequency was 59.2%, apnea hypopnea index was 43.62 and mean continuous positive airway pressure was 12.50 . There was significant relationship among the pressure of continuous positive airway pressure with apnea hypopnea index (P=0.028, arousal index (P=0.011, body mass index (P=0.041 and O2 desaturation index (P=0.022, although age was not significantly related.   Conclusion: In accordance to this data, we found out a prediction equation for optimal CPAP in our patients

  16. Gadolinium prevents high airway pressure-induced permeability increases in isolated rat lungs.

    Science.gov (United States)

    Parker, J C; Ivey, C L; Tucker, J A

    1998-04-01

    To determine the initial signaling event in the vascular permeability increase after high airway pressure injury, we compared groups of lungs ventilated at different peak inflation pressures (PIPs) with (gadolinium group) and without (control group) infusion of 20 microM gadolinium chloride, an inhibitor of endothelial stretch-activated cation channels. Microvascular permeability was assessed by using the capillary filtration coefficient (Kfc), a measure of capillary hydraulic conductivity. Kfc was measured after ventilation for 30-min periods with 7, 20, and 30 cmH2O PIP with 3 cmH2O positive end-expiratory pressure and with 35 cmH2O PIP with 8 cmH2O positive end-expiratory pressure. In control lungs, Kfc increased significantly to 1.8 and 3.7 times baseline after 30 and 35 cmH2O PIP, respectively. In the gadolinium group, Kfc was unchanged from baseline (0.060 +/- 0.010 ml . min-1 . cmH2O-1 . 100 g-1) after any PIP ventilation period. Pulmonary vascular resistance increased significantly from baseline in both groups before the last Kfc measurement but was not different between groups. These results suggest that microvascular permeability is actively modulated by a cellular response to mechanical injury and that stretch-activated cation channels may initiate this response through increases in intracellular calcium concentration.

  17. Comparison of three continuous positive airway pressure (CPAP) interfaces in healthy Beagle dogs during medetomidine-propofol constant rate infusions.

    Science.gov (United States)

    Meira, Carolina; Joerger, Fabiola B; Kutter, Annette P N; Waldmann, Andreas; Ringer, Simone K; Böehm, Stephan H; Iff, Samuel; Mosing, Martina

    2018-03-01

    To compare the efficacy of three continuous positive airway pressure (CPAP) interfaces in dogs on gas exchange, lung volumes, amount of leak during CPAP and rebreathing in case of equipment failure or disconnection. Randomized, prospective, crossover, experimental trial. Ten purpose-bred Beagle dogs. Dogs were in dorsal recumbency during medetomidine-propofol constant rate infusions, breathing room air. Three interfaces were tested in each dog in a consecutive random order: custom-made mask (M), conical face mask (FM) and helmet (H). End-expiratory lung impedance (EELI) measured by electrical impedance tomography was assessed with no interface (baseline), with the interface only (No-CPAP for 3 minutes) and at 15 minutes of 7 cmH 2 O CPAP (CPAP-delivery). PaO 2 was assessed at No-CPAP and CPAP-delivery, partial pressure of inspired carbon dioxide (PICO 2 ; rebreathing assessment) at No-CPAP and the interface leak (ΔP leak ) at CPAP-delivery. Mixed-effects linear regression models were used for statistical analysis (pCPAP-delivery, all interfaces increased EELI by 7% (pCPAP, less rebreathing occurred with M (0.5 kPa, 4 mmHg) than with FM (1.8 kPa, 14 mmHg) and with H (1.4 kPa, 11 mmHg), but also lower PaO 2 was measured with M (9.3 kPa, 70 mmHg) than with H (11.9 kPa, 90 mmHg) and FM (10.8 kPa, 81 mmHg). All three interfaces can be used to provide adequate CPAP in dogs. The leak during CPAP-delivery and the risk of rebreathing and hypoxaemia, when CPAP is not maintained, can be significant. Therefore, animals should always be supervised during administration of CPAP with any of the three interfaces. The performance of the custom-made M was not superior to the other interfaces. Copyright © 2017 Association of Veterinary Anaesthetists and American College of Veterinary Anesthesia and Analgesia. Published by Elsevier Ltd. All rights reserved.

  18. Continuous positive airway pressure and conventional mechanical ventilation in the treatment of meconium aspiration syndrome.

    Science.gov (United States)

    Goldsmith, J P

    2008-12-01

    Meconium aspiration syndrome (MAS) is a complex syndrome that ranges in severity from mild respiratory distress to severe respiratory failure, persistent pulmonary hypertension of the newborn and sometimes death. Understanding of the syndrome's complicated pathophysiology will help determine the appropriate treatment strategy, including the use of continuous positive airway pressure (CPAP), conventional mechanical ventilation (CMV) and other therapies. Approximately 30 to 50% of infants diagnosed with MAS will require CPAP or mechanical ventilation. The optimum modes of ventilation for MAS are not known. Very few studies have been conducted to determine 'best' ventilatory strategies. Despite the introduction, over the last two decades, of innovative ventilatory treatments for this disease (for example, surfactant, high-frequency ventilation, inhaled nitric oxide, extracorporeal membrane oxygenation), the majority of infants can be successfully managed with CPAP or mechanical ventilation alone.

  19. Cardiovascular risk in patients with sleep apnoea with or without continuous positive airway pressure therapy

    DEFF Research Database (Denmark)

    Lamberts, Morten; Nielsen, O W; Lip, G Y H

    2014-01-01

    BACKGROUND: The prognostic significance of age and continuous positive airway pressure (CPAP) therapy on cardiovascular disease in patients with sleep apnoea has not been assessed previously. METHODS: Using nationwide databases, the entire Danish population was followed from 2000 until 2011. First......-time sleep apnoea diagnoses and use of CPAP therapy were determined. Incidence rate ratios (IRRs) of ischaemic stroke and myocardial infarction (MI) were analysed using Poisson regression models. RESULTS: Amongst 4.5 million individuals included in the study, 33 274 developed sleep apnoea (mean age 53, 79......% men) of whom 44% received persistent CPAP therapy. Median time to initiation of CPAP therapy was 88 days (interquartile range 34-346). Patients with sleep apnoea had more comorbidities compared to the general population. Crude rates of MI and ischaemic stroke were increased for sleep apnoea patients...

  20. Sleep architecture, insulin resistance and the nasal cycle: Implications for positive airway pressure therapy

    Directory of Open Access Journals (Sweden)

    Catherine A.P. Crofts

    2018-03-01

    Full Text Available Background: The global pandemic of metabolic disease is worsening. The metabolic theory of obesity proposes that hormonal changes, especially hyperinsulinaemia, precede metabolic disease development. Although quality sleep is recognised as a key factor for good health, less is known about disrupted sleep as a risk factor for hyperinsulinaemia.   Aim: To explore the relationship between sleep, especially sleep architecture and the nasal cycle, on insulin secretion in obstructive sleep apnoea (OSA with comorbid metabolic disease. This review includes a discussion of the potential role of Rest-Activity-Cycler positive airway pressure (RACer-PAP, a novel non-pharmacological OSA treatment strategy.   Methods: A narrative review of all the relevant papers known to the authors was conducted. This review also included results from a polysomnographic sleep clinic pilot study (n = 3 comparing sleep efficiency of RACer-PAP to nasal continuous positive airways pressure (n-CPAP in OSA patients.   Results: Metabolic disease is strongly associated with disturbed sleep. Sleep architecture influences cerebral hormonal secretion, lateral shifts in the autonomic nervous system and nasal airflow dominance. Disturbed sleep shortens short-wave sleep periods, decreasing insulin sensitivity and glucose tolerance. Improvements to metabolic function during n-CPAP treatment are inconsistent. If RACer-PAP demonstrates superior effects on sleep architecture and autonomic function, it may offer advantages in OSA patients with comorbid metabolic disease.   Conclusion: Improving sleep architecture by maintaining the nasal cycle proposes a novel non-pharmacological treatment paradigm for treating OSA with comorbid metabolic disease. Research is required to demonstrate if RACer-PAP therapy influences whole night sleep architecture, sympathovagal balance and markers of metabolic disease.

  1. Treatment of presumed acute cardiogenic pulmonary oedema in an ambulance system by nurses using Boussignac continuous positive airway pressure

    NARCIS (Netherlands)

    Dieperink, Willem; Weelink, E. E. M.; van der Horst, I. C. C.; de Vos, R.; Jaarsma, T.; Aarts, L. P. H. J.; Zijlstra, F.; Nijsten, M. W. N.

    Background: Early initiation of continuous positive airway pressure (CPAP) applied by face mask benefits patients with acute cardiogenic pulmonary oedema (ACPE). The simple disposable Boussignac CPAP (BCPAP) has been used in ambulances by physicians. In the Netherlands, ambulances are manned by

  2. Simulated driving in obstructive sleep apnoea-hypopnoea : effects of oral appliances and continuous positive airway pressure

    NARCIS (Netherlands)

    Hoekema, Aarnoud; Stegenga, Boudewijn; Bakker, Marije; Brouwer, Wiebo H.; de Bont, Lambert G. M.; Wijkstra, Peter J.; van der Hoeven, Johannes H.

    Impaired simulated driving performance has been demonstrated in obstructive sleep apnoea-hypopnoea syndrome (OSAHS) patients. Although continuous positive airway pressure (CPAP) generally improves simulated driving performance, the effects of oral-appliance (OA) therapy are unknown. The aims of this

  3. Does personality play a role in continuous positive airway pressure compliance?

    Directory of Open Access Journals (Sweden)

    Emily L. Maschauer

    2017-03-01

    Continuous positive airway pressure (CPAP adherence is low among individuals with obstructive sleep apnoea. Type D personality and high scores on the depression and hypochondriasis scales on the Minnesota Multiphasic Personality Inventory (MMPI have been identified as factors contributing to non-compliance with CPAP. Further research into personality type may assist in understanding why some people adhere to CPAP, while others fail. Obstructive sleep apnoea (OSA is a condition characterised by repetitive, intermittent partial or complete collapse/obstruction of the upper airway during sleep. Continuous positive airway pressure (CPAP is highly efficacious in treating OSA but its effectiveness is limited due to suboptimal acceptance and adherence rates, with as many as 50% of OSA patients discontinuing CPAP treatment within the first year. Until recently, research has focused on examining mechanistic and demographic factors that could explain nonadherence (e.g. age, sex, race and education level with limited applicability in a prospective or clinical manner. More recent research has focused on personality factors or types of patients with OSA who comply and do not comply with CPAP adherence in an attempt to enhance the accuracy of predicting treatment compliance. Type D personality has been found to be prevalent in one third of patients with OSA. The presence of Type D personality increases noncompliance and poor treatment outcomes due to negative affectivity, social inhibition, unhealthy lifestyle, and a reluctance to consult and/or follow medical advice. Conversely, individuals who are more likely to adhere to CPAP treatment tend to have a high internal locus of control and high self-efficacy, self-refer for treatment, and have active coping skills. By assessing personality and coping skills, the clinician may gain insight into the likelihood of a patient’s adherence to treatment. If the patient displays potential risk factors for CPAP noncompliance, the

  4. Understanding the use of continuous oscillating positive airway pressure (bubble CPAP) to treat neonatal respiratory disease: an engineering approach.

    Science.gov (United States)

    Manilal-Reddy, P I; Al-Jumaily, A M

    2009-01-01

    A continuous oscillatory positive airway pressure with pressure oscillations incidental to the mean airway pressure (bubble CPAP) is defined as a modified form of traditional continuous positive airway pressure (CPAP) delivery where pressure oscillations in addition to CPAP are administered to neonates with lung diseases. The mechanical effect of the pressure oscillations on lung performance is investigated by formulating mathematical models of a typical bubble CPAP device and a simple representation of a neonatal respiratory system. Preliminary results of the respiratory system's mechanical response suggest that bubble CPAP may improve lung performance by minimizing the respiratory system impedance and that the resonant frequency of the respiratory system may be a controlling factor. Additional steps in terms of clinical trials and a more complex respiratory system model are required to gain a deeper insight into the mechanical receptiveness of the respiratory system to pressure oscillations. However, the current results are promising in that they offer a deeper insight into the trends of variations that can be expected in future extended models as well as the model philosophies that need to be adopted to produce results that are compatible with experimental verification.

  5. Prevention of Hypoxemia During Apnea Testing: A Comparison of Oxygen Insufflation And Continuous Positive Airway Pressure.

    Science.gov (United States)

    Kramer, Andreas H; Couillard, Philippe; Bader, Ryan; Dhillon, Peter; Kutsogiannis, Demetrios J; Doig, Christopher J

    2017-08-01

    Apnea testing is an essential step in the clinical diagnosis of brain death. Current international guidelines recommend placement of an oxygen (O 2 ) insufflation catheter into the endotracheal tube to prevent hypoxemia, but use of a continuous positive airway pressure (CPAP) valve may be more effective at limiting arterial partial pressure of O 2 (PO 2 ) reduction. We performed a multicenter study assessing consecutive apnea tests in 14 intensive care units (ICUs) in two cities utilizing differing protocols. In one city, O 2 catheters are placed and arterial blood gases (ABGs) performed at intervals determined by the attending physician. In the other city, a resuscitation bag with CPAP valve is attached to the endotracheal tube, and ABGs performed every 3-5 min. We assessed arterial PO 2 , partial pressure of carbon dioxide (PCO 2 ), pH, and blood pressure at the beginning and termination of each apnea test. Thirty-six apnea tests were performed using an O 2 catheter and 50 with a CPAP valve. One test per group was aborted because of physiological instability. There were no significant differences in the degree of PO 2 reduction (-59 vs. -32 mmHg, p = 0.72), rate of PCO 2 rise (3.2 vs. 3.9 mmHg per min, p = 0.22), or pH decline (-0.02 vs. -0.03 per min, p = 0.06). Performance of ABGs at regular intervals was associated with shorter test duration (10 vs. 7 min, p pressure decline (p = 0.006). Both methods of O 2 supplementation are associated with similar changes in arterial PO 2 and PCO 2 . Performance of ABGs at regular intervals shortens apnea test duration and may avoid excessive pH reduction and consequent hemodynamic effects.

  6. Type of mask may impact on continuous positive airway pressure adherence in apneic patients.

    Science.gov (United States)

    Borel, Jean Christian; Tamisier, Renaud; Dias-Domingos, Sonia; Sapene, Marc; Martin, Francis; Stach, Bruno; Grillet, Yves; Muir, Jean François; Levy, Patrick; Series, Frederic; Pepin, Jean-Louis

    2013-01-01

    In obstructive sleep apnea patients (OSA), continuous positive airway pressure (CPAP) adherence is crucial to improve symptoms and cardiometabolic outcomes. The choice of mask may influence CPAP adherence but this issue has never been addressed properly. To evaluate the impact of nasal pillows, nasal and oronasal masks on CPAP adherence in a cohort of OSA. Newly CPAP treated OSA participating in "Observatoire Sommeil de la Fédération de Pneumologie", a French national prospective cohort, were included between March 2009 and December 2011. Anthropometric data, medical history, OSA severity, sleepiness, depressive status, treatment modalities (auto-CPAP versus fixed pressure, pressure level, interface type, use of humidifiers) and CPAP-related side effects were included in multivariate analysis to determine independent variables associated with CPAP adherence. 2311 OSA (age = 57(12) years, apnea+hypopnea index = 41(21)/h, 29% female) were included. Nasal masks, oronasal masks and nasal pillows were used by 62.4, 26.2 and 11.4% of the patients, respectively. In univariate analysis, oronasal masks and nasal pillows were associated with higher risk of CPAP non-adherence. CPAP non-adherence was also associated with younger age, female gender, mild OSA, gastroesophageal reflux, depression status, low effective pressure and CPAP-related side effects. In multivariate analysis, CPAP non-adherence was associated with the use of oronasal masks (OR = 2.0; 95%CI = 1.6; 2.5), depression, low effective pressure, and side effects. As oronasal masks negatively impact on CPAP adherence, a nasal mask should be preferred as the first option. Patients on oronasal masks should be carefully followed.

  7. Type of mask may impact on continuous positive airway pressure adherence in apneic patients.

    Directory of Open Access Journals (Sweden)

    Jean Christian Borel

    Full Text Available RATIONALE: In obstructive sleep apnea patients (OSA, continuous positive airway pressure (CPAP adherence is crucial to improve symptoms and cardiometabolic outcomes. The choice of mask may influence CPAP adherence but this issue has never been addressed properly. OBJECTIVE: To evaluate the impact of nasal pillows, nasal and oronasal masks on CPAP adherence in a cohort of OSA. METHODS: Newly CPAP treated OSA participating in "Observatoire Sommeil de la Fédération de Pneumologie", a French national prospective cohort, were included between March 2009 and December 2011. Anthropometric data, medical history, OSA severity, sleepiness, depressive status, treatment modalities (auto-CPAP versus fixed pressure, pressure level, interface type, use of humidifiers and CPAP-related side effects were included in multivariate analysis to determine independent variables associated with CPAP adherence. RESULTS: 2311 OSA (age = 57(12 years, apnea+hypopnea index = 41(21/h, 29% female were included. Nasal masks, oronasal masks and nasal pillows were used by 62.4, 26.2 and 11.4% of the patients, respectively. In univariate analysis, oronasal masks and nasal pillows were associated with higher risk of CPAP non-adherence. CPAP non-adherence was also associated with younger age, female gender, mild OSA, gastroesophageal reflux, depression status, low effective pressure and CPAP-related side effects. In multivariate analysis, CPAP non-adherence was associated with the use of oronasal masks (OR = 2.0; 95%CI = 1.6; 2.5, depression, low effective pressure, and side effects. CONCLUSION: As oronasal masks negatively impact on CPAP adherence, a nasal mask should be preferred as the first option. Patients on oronasal masks should be carefully followed.

  8. BreathSens: A Continuous On-Bed Respiratory Monitoring System With Torso Localization Using an Unobtrusive Pressure Sensing Array.

    Science.gov (United States)

    Liu, Jason J; Huang, Ming-Chun; Xu, Wenyao; Zhang, Xiaoyi; Stevens, Luke; Alshurafa, Nabil; Sarrafzadeh, Majid

    2015-09-01

    The ability to continuously monitor respiration rates of patients in homecare or in clinics is an important goal. Past research showed that monitoring patient breathing can lower the associated mortality rates for long-term bedridden patients. Nowadays, in-bed sensors consisting of pressure sensitive arrays are unobtrusive and are suitable for deployment in a wide range of settings. Such systems aim to extract respiratory signals from time-series pressure sequences. However, variance of movements, such as unpredictable extremities activities, affect the quality of the extracted respiratory signals. BreathSens, a high-density pressure sensing system made of e-Textile, profiles the underbody pressure distribution and localizes torso area based on the high-resolution pressure images. With a robust bodyparts localization algorithm, respiratory signals extracted from the localized torso area are insensitive to arbitrary extremities movements. In a study of 12 subjects, BreathSens demonstrated its respiratory monitoring capability with variations of sleep postures, locations, and commonly tilted clinical bed conditions.

  9. Low flow anesthesia: Efficacy and outcome of laryngeal mask airway versus pressure-optimized cuffed-endotracheal tube

    Directory of Open Access Journals (Sweden)

    El-Seify Zeinab

    2010-01-01

    Full Text Available Background: Low flow anesthesia can lead to reduction of anesthetic gas and vapor consumption. Laryngeal mask airway (LMA has proved to be an effective and safe airway device. The aim of this study is to assess the feasibility of laryngeal mask airway during controlled ventilation using low fresh gas flow (1.0 L/min as compared to endotracheal tube (ETT. Patients and Methods : Fifty nine non-smoking adult patients; ASA I or II, being scheduled for elective surgical procedures, with an expected duration of anesthesia 60 minutes or more, were randomly allocated into two groups - Group I (29 patients had been ventilated using LMA size 4 for females and 5 for males respectively; and Group II (30 patients were intubated using ETT. After 10 minutes of high fresh gas flow, the flow was reduced to 1 L/min. Patients were monitored for airway leakage, end-tidal CO 2 (ETCO 2 , inspiratory and expiratory isoflurane and nitrous oxide fraction concentrations, and postoperative airway-related complications Results : Two patients in the LMA-group developed initial airway leakage (6.9% versus no patient in ETT-group. Cough and sore throat were significantly higher in ETT patients. There were no evidences of differences between both groups regarding ETCO 2 , uptake of gases, nor difficulty in swallowing. Conclusion : The laryngeal mask airway proved to be effective and safe in establishing an airtight seal during controlled ventilation under low fresh gas flow of 1 L/min, inducing less coughing and sore throat during the immediate postoperative period than did the ETT, with continuous measurement and readjustment of the tube cuff pressure.

  10. Pressure support ventilation vs Continuous positive airway pressure for treating of acute cardiogenic pulmonary edema: A pilot study.

    Science.gov (United States)

    Pagano, Antonio; Numis, Fabio G; Rosato, Valerio; Russo, Teresa; Porta, Giovanni; Bosso, Giorgio; Serra, Claudia; Masarone, Mario; Visone, Giuseppe; Paladino, Fiorella

    2018-04-24

    Non-invasive ventilation is usually adopted as a support to medical therapy in patients with acute pulmonary edema, but which modality between Pressure Support Ventilation (PSV) and Continuous Positive Airway Pressure (CPAP) has better favourable effects is not been yet well known. Aim of this observational study was to provide data on these different non-invasive ventilation modalities in the management of acute cardiogenic pulmonary edema. One-hundred-fifty-three patients consecutively admitted to the Emergency Room of two different Center were enrolled and randomly assigned to CPAP or PSV. Data relative to mortality, need of endotracheal intubation, sequential blood gas analysis were compared. Furthermore, there were no significant differences regarding mortality in the two groups, but patients treated with PSV had a significant lower rate of endotracheal intubation and a higher improvement of blood gas analyses parameters. In conclusion, our data support only a slight advantage in favour to PSV versus CPAP. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Comparison of Laryngeal Mask Airway Supreme and Laryngeal Mask Airway Proseal with respect to oropharyngeal leak pressure during laparoscopic cholecystectomy: a randomised controlled trial.

    Science.gov (United States)

    Beleña, José M; Núñez, Mónica; Anta, Diego; Carnero, Maria; Gracia, José L; Ayala, José L; Alvarez, Raquel; Yuste, Javier

    2013-03-01

    A comparison of the efficacy and safety of the Laryngeal Mask Airway (LMA) Supreme (LMAS) versus the LMA Proseal (LMAP) in elective laparoscopic cholecystectomy. To compare the LMAS with LMAP in terms of ventilatory efficacy, airway leak pressure (airway protection), ease-of-use and complications. Prospective, single-blind, randomised, controlled study. The Hospital del Sureste and Hospital Ramon y Cajal, Madrid, between May 2009 and March 2011. The Hospital del Sureste is a secondary hospital and Hospital Ramon y Cajal is a tertiary hospital. Patients undergoing elective laparoscopic cholecystectomy were studied following informed consent. Inclusion criteria were American Society of Anesthesiologists physical status I to III and age 18 or more. Exclusion criteria were BMI more than 40 kg m, symptomatic hiatus hernia or severe gastro-oesophageal reflux. Anaesthesiologists experienced in the use of LMAP and LMAS participated in the trial. One hundred twenty-two patients were randomly allocated to LMAS or LMAP. Our primary outcome measure was the oropharyngeal leak pressure (OLP). Secondary outcomes were the time and number of attempts for insertion, ease of insertion of the drain tube, adequacy of ventilation and the incidence of complication. Patients were interviewed postoperatively to evaluate the presence of sore throat, dysphagia or dysphonia. Two patients were excluded when surgery changed from laparoscopic to open. A total of 120 patients were finally included in the analysis. The mean OLP in the LMAP group was significantly higher than that in the LMAS group (30.7 ± 6.2 versus 26.8 ± 4.1 cmH2O;P drain tube, complications and postoperative pharyngolaryngeal adverse events were similar in both groups. The LMAP has a higher OLP and achieves a higher maximum tidal volume compared to the LMAS, in patients undergoing elective laparoscopic cholecystectomy. The success of the first attempt insertion was higher for the LMAS.

  12. Bilateral parotitis in a patient under continuous positive airway pressure treatment.

    Science.gov (United States)

    Abdullayev, Ruslan; Saral, Filiz Cosku; Kucukebe, Omer Burak; Sayiner, Hakan Sezgin; Bayraktar, Cem; Akgun, Sadik

    Many conditions such as bacterial and viral infectious diseases, mechanical obstruction due to air and calculi and drugs can cause parotitis. We present a case of unusual bilateral parotitis in a patient under non-invasive continuous positive airway pressure (CPAP) therapy for chronic obstructive pulmonary disease exacerbation in intensive care unit. A 36-year-old patient was admitted to intensive care unit with the diagnosis of chronic obstructive pulmonary disease exacerbation. Antibiotherapy, bronchodilator therapy and non-invasive positive pressure ventilation were applied as treatment regimen. Painless swellings developed on the 3rd day of admission on the right and a day after this on the left parotid glands. Amylase levels were increased and ultrasonographic evaluation revealed bilateral parotitis. No intervention was made and the therapy was continued. The patient was discharged on the 6th day with clinical improvement and regression of parotid swellings without any complications. Parotitis may have occurred after retrograde air flow in the Stensen duct during CPAP application. After the exclusion of possible viral and bacteriological etiologies and possible drug reactions we can focus on this diagnosis. Copyright © 2014 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.

  13. Delivery room continuous positive airway pressure and early pneumothorax in term newborn infants.

    Science.gov (United States)

    Clevenger, L; Britton, J R

    2017-01-01

    To assess the association between delivery room (DR) continuous positive airway pressure (CPAP) and pneumothorax (PT) in term newborns. Two studies performed in community hospitals used data extracted from computerized records of term newborns. Infants receiving positive pressure ventilation in the DR were excluded. Tabulated data included receipt of DR CPAP, PT on the day of birth, and gestational age (GA). In a case-control study from 2001-2013, infants with PT were compared to controls without PT but with respiratory distress or hypoxia persisting from birth for receipt of DR CPAP. In a cohort study from 2014-2016, infants receiving and not receiving DR CPAP were compared for the incidence of PT. In the case-control study, data were obtained for 169 cases and 850 controls. Compared to controls, PT infants were more likely to have received DR CPAP (16.8% vs. 40.2%, respectively, P CPAP (Adjusted Odds Ratio [AOR] = 3.30, 95% confidence interval [CI] = 2.31, 4.72, P CPAP and 4.8% of 228 infants receiving DR CPAP (P CPAP significantly predicted PT (OR = 59.59, 95% CI = 23.34, 147.12, P CPAP in delivery rooms are associated with increased risk of PT. A cause-and-effect relationship between CPAP and PT cannot be claimed in this study. Further research is needed to better understand this relationship.

  14. Phosphotyrosine phosphatase and tyrosine kinase inhibition modulate airway pressure-induced lung injury.

    Science.gov (United States)

    Parker, J C; Ivey, C L; Tucker, A

    1998-11-01

    We determined whether drugs which modulate the state of protein tyrosine phosphorylation could alter the threshold for high airway pressure-induced microvascular injury in isolated perfused rat lungs. Lungs were ventilated for successive 30-min periods with peak inflation pressures (PIP) of 7, 20, 30, and 35 cmH2O followed by measurement of the capillary filtration coefficient (Kfc), a sensitive index of hydraulic conductance. In untreated control lungs, Kfc increased by 1.3- and 3.3-fold relative to baseline (7 cmH2O PIP) after ventilation with 30 and 35 cmH2O PIP. However, in lungs treated with 100 microM phenylarsine oxide (a phosphotyrosine phosphatase inhibitor), Kfc increased by 4.7- and 16.4-fold relative to baseline at these PIP values. In lungs treated with 50 microM genistein (a tyrosine kinase inhibitor), Kfc increased significantly only at 35 cmH2O PIP, and the three groups were significantly different from each other. Thus phosphotyrosine phosphatase inhibition increased the susceptibility of rat lungs to high-PIP injury, and tyrosine kinase inhibition attenuated the injury relative to the high-PIP control lungs.

  15. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Physical Therapy Coughing and Huffing High-Frequency Chest Wall Oscillation Positive Expiratory Pressure Clinical Trials Clinical Trials ... clapping) or vibration to loosen mucus from airway walls. See how different airway clearance techniques work to ...

  16. Is the Relationship between Race and Continuous Positive Airway Pressure Adherence Mediated by Sleep Duration?

    Science.gov (United States)

    Billings, Martha E.; Rosen, Carol L.; Wang, Rui; Auckley, Dennis; Benca, Ruth; Foldvary-Schaefer, Nancy; Iber, Conrad; Zee, Phyllis; Redline, Susan; Kapur, Vishesh K.

    2013-01-01

    Study Objectives: Black race has been associated with decreased continuous positive airway pressure (CPAP) adherence. Short sleep duration, long sleep latency, and insomnia complaints may affect CPAP adherence as they affect sleep and opportunity to use CPAP. We assessed whether self-reported sleep measures were associated with CPAP adherence and if racial variations in these sleep characteristics may explain racial differences in CPAP adherence. Design: Analysis of data from a randomized controlled trial (HomePAP), which investigated home versus laboratory-based diagnosis and treatment of obstructive sleep apnea. Setting: Seven American Academy of Sleep Medicine-accredited sleep centers in five cities in the United States. Patients or Participants: Enrolled subjects (n = 191) with apnea-hypopnea index ≥ 15 and sleepiness (Epworth Sleepiness Scale > 12). Interventions: N/A. Measurements and Results: Multivariable regression was used to assess if subjective sleep measures and symptoms predicted 3-mo CPAP use. Mediation analysis was used to assess if sleep measures mediated the association of race with CPAP adherence. Black participants reported shorter sleep duration and longer sleep latency at baseline than white and Hispanic participants. Shorter sleep duration and longer sleep latency predicted worse CPAP adherence. Sleep duration mediated the association of black race with lower CPAP adherence. However, insomnia symptoms were not associated with race or CPAP adherence. Conclusions: Among subjects with similar severity of obstructive sleep apnea and sleepiness, baseline self-reported sleep duration and latency, but not perceived insomnia, predicted CPAP adherence over 3 mo. Sleep duration explains some of the observed differences in CPAP use by race. Sleep duration and latency should be considered when evaluating poor CPAP adherence. Clinical Trial Information: Portable Monitoring for Diagnosis and Management of Sleep Apnea (HomePAP) URL: http

  17. Effect of Continuous Positive Airway Pressure on Stroke Rehabilitation: A Pilot Randomized Sham-Controlled Trial

    Science.gov (United States)

    Khot, Sandeep P.; Davis, Arielle P.; Crane, Deborah A.; Tanzi, Patricia M.; Li Lue, Denise; Claflin, Edward S.; Becker, Kyra J.; Longstreth, W.T.; Watson, Nathaniel F.; Billings, Martha E.

    2016-01-01

    Study Objectives: Obstructive sleep apnea (OSA) predicts poor functional outcome after stroke and increases the risk for recurrent stroke. Less is known about continuous positive airway pressure (CPAP) treatment on stroke recovery. Methods: In a pilot randomized, double-blind, sham-controlled trial, adult stroke rehabilitation patients were assigned to auto-titrating or sham CPAP without diagnostic testing for OSA. Change in Functional Independence Measure (FIM), a measure of disability, was assessed between rehabilitation admission and discharge. Results: Over 18 months, 40 patients were enrolled and 10 withdrew from the study: 7 from active and 3 from sham CPAP (p > 0.10). For the remaining 30 patients, median duration of CPAP use was 14 days. Average CPAP use was 3.7 h/night, with at least 4 h nightly use among 15 patients. Adherence was not influenced by treatment assignment or stroke severity. In intention-to-treat analyses (n = 40), the median change in FIM favored active CPAP over sham but did not reach statistical significance (34 versus 26, p = 0.25), except for the cognitive component (6 versus 2.5, p = 0.04). The on-treatment analyses (n = 30) yielded similar results (total FIM: 32 versus 26, p = 0.11; cognitive FIM: 6 versus 2, p = 0.06). Conclusions: A sham-controlled CPAP trial among stroke rehabilitation patients was feasible in terms of recruitment, treatment without diagnostic testing and adequate blinding—though was limited by study retention and CPAP adherence. Despite these limitations, a trend towards a benefit of CPAP on recovery was evident. Tolerance and adherence must be improved before the full benefits of CPAP on recovery can be assessed in larger trials. Citation: Khot SP, Davis AP, Crane DA, Tanzi PM, Li Lue D, Claflin ES, Becker KJ, Longstreth WT, Watson NF, Billings ME. Effect of continuous positive airway pressure on stroke rehabilitation: a pilot randomized sham-controlled trial. J Clin Sleep Med 2016;12(7):1019–1026. PMID

  18. Nasal bi-level positive airway pressure (BiPAP) versus nasal continuous positive airway pressure (CPAP) in preterm infants ≤32 weeks: A retrospective cohort study.

    Science.gov (United States)

    Rong, Zhi-Hui; Li, Wen-Bin; Liu, Wei; Cai, Bao-Huan; Wang, Jing; Yang, Min; Li, Wei; Chang, Li-Wen

    2016-05-01

    To investigate whether Bi-level positive airway pressure (BiPAP), compared with nasal continuous positive airway pressure (CPAP), is a more effective therapeutic strategy in preterm infants ≤32 weeks. All inborn infants between 26(+1) and 32(+6) weeks' gestation, admitted to the neonatal intensive care unit (NICU ) of Tongji Medical Hospital between 1 January, 2010 and 31 December, 2011 (the 2010-2011 cohort or CPAP cohort) and between 1 January, 2012 and 31 December, 2013 (the 2012-2013 cohort or BiPAP cohort), were retrospectively identified. The primary outcome was intubation in infants CPAP were subsequently intubated (P CPAP, reduced the need for intubation within the first 72 h of age. © 2016 Paediatrics and Child Health Division (The Royal Australasian College of Physicians).

  19. Prediction of high airway pressure using a non-linear autoregressive model of pulmonary mechanics.

    Science.gov (United States)

    Langdon, Ruby; Docherty, Paul D; Schranz, Christoph; Chase, J Geoffrey

    2017-11-02

    For mechanically ventilated patients with acute respiratory distress syndrome (ARDS), suboptimal PEEP levels can cause ventilator induced lung injury (VILI). In particular, high PEEP and high peak inspiratory pressures (PIP) can cause over distension of alveoli that is associated with VILI. However, PEEP must also be sufficient to maintain recruitment in ARDS lungs. A lung model that accurately and precisely predicts the outcome of an increase in PEEP may allow dangerous high PIP to be avoided, and reduce the incidence of VILI. Sixteen pressure-flow data sets were collected from nine mechanically ventilated ARDs patients that underwent one or more recruitment manoeuvres. A nonlinear autoregressive (NARX) model was identified on one or more adjacent PEEP steps, and extrapolated to predict PIP at 2, 4, and 6 cmH 2 O PEEP horizons. The analysis considered whether the predicted and measured PIP exceeded a threshold of 40 cmH 2 O. A direct comparison of the method was made using the first order model of pulmonary mechanics (FOM(I)). Additionally, a further, more clinically appropriate method for the FOM was tested, in which the FOM was trained on a single PEEP prior to prediction (FOM(II)). The NARX model exhibited very high sensitivity (> 0.96) in all cases, and a high specificity (> 0.88). While both FOM methods had a high specificity (> 0.96), the sensitivity was much lower, with a mean of 0.68 for FOM(I), and 0.82 for FOM(II). Clinically, false negatives are more harmful than false positives, as a high PIP may result in distension and VILI. Thus, the NARX model may be more effective than the FOM in allowing clinicians to reduce the risk of applying a PEEP that results in dangerously high airway pressures.

  20. A passive quantitative measurement of airway resistance using depth data.

    Science.gov (United States)

    Ostadabbas, Sarah; Bulach, Christoph; Ku, David N; Anderson, Larry J; Ghovanloo, Maysam

    2014-01-01

    The Respiratory Syncytial Virus (RSV) is the most common cause of serious lower respiratory tract infections in infants and young children. RSV often causes increased airway resistance, clinically detected as wheezing by chest auscultation. In this disease, expiratory flows are significantly reduced due to the high resistance in patient's airway passages. A quantitative method for measuring resistance can have a great benefit to diagnosis and management of children with RSV infections as well as with other lung diseases. Airway resistance is defined as the lung pressure divided by the airflow. In this paper, we propose a method to quantify resistance through a simple, non-contact measurement of chest volume that can act as a surrogate measure of the lung pressure and volumetric airflow. We used depth data collected by a Microsoft Kinect camera for the measurement of the lung volume over time. In our experimentation, breathing through a number of plastic straws induced different airway resistances. For a standard spirometry test, our volume/flow estimation using Kinect showed strong correlation with the flow data collected by a commercially-available spirometer (five subjects, each performing 20 breathing trials, correlation coefficient = 0.88, with 95% confidence interval). As the number of straws decreased, emulating a higher airway obstruction, our algorithm was sufficient to distinguish between several levels of airway resistance.

  1. Asthma outcomes improve with continuous positive airway pressure for obstructive sleep apnea.

    Science.gov (United States)

    Serrano-Pariente, J; Plaza, V; Soriano, J B; Mayos, M; López-Viña, A; Picado, C; Vigil, L

    2017-05-01

    Continuous positive airway pressure (CPAP) in asthma patients with concomitant obstructive sleep apnea syndrome (OSAS) seems to have a favorable impact on asthma, but data are inconsistent due to methodological limitations of previous studies. Prospective, multicenter study. We examined asthma outcomes after 6 months of CPAP in 99 adult asthma patients (mean age 57 years) with OSAS (respiratory disturbance index ≥20). Asthma control and quality of life were assessed with the Asthma Control Questionnaire (ACQ) and the Mini Asthma Quality of Life Questionnaire (MiniAQLQ), respectively. Data were analyzed by intention-to-treat basis. The mean ± SD score of the ACQ decreased from 1.39 ± 0.91 at baseline to 1.0 ± 0.78 at 6 months (P = 0.003), the percentage of patients with uncontrolled asthma from 41.4% to 17.2% (P = 0.006), and the percentage of patients with asthma attacks in the 6 months before and after treatment from 35.4% to 17.2% (P = 0.015). The score of the mAQLQ increased from 5.12 ± 1.38 to 5.63 ± 1.17 (P = 0.009). There were also significant improvements in symptoms of gastroesophageal reflux and rhinitis, bronchial reversibility, and exhaled nitric oxide values (all P obstructive sleep apnea syndrome. © 2016 The Authors. Allergy published by John Wiley & Sons Ltd.

  2. Dynamic airway pressure-time curve profile (Stress Index): a systematic review.

    Science.gov (United States)

    Terragni, Pierpaolo; Bussone, Guido; Mascia, Luciana

    2016-01-01

    The assessment of respiratory mechanics at the bedside is necessary in order to identify the most protective ventilatory strategy. Indeed in the last 20 years, adverse effects of positive ventilation to the lung structures have led to a reappraisal of the objectives of mechanical ventilation. The ventilator setting requires repeated readjustment over the period of mechanical ventilation dependency and careful respiratory monitoring to minimize the risks, preventing further injury and permitting the lung and airways healing. Among the different methods that have been proposed and validated, the analysis of dynamic P-t curve (named Stress Index, SI) represents an adequate tool available at the bedside, repeatable and, therefore, able to identify the amount of overdistension occurring in the daily clinical practice, when modifying positive end-expiratory pressure. In this review we will analyze the evidence that supports respiratory mechanics assessment at the bedside and the application of the dynamic P/t curve profile (SI) to optimize protective ventilation in patients with acute respiratory failure.

  3. Continuous Positive Airway Pressure Device Time to Procurement in a Disadvantaged Population

    Directory of Open Access Journals (Sweden)

    Lourdes M. DelRosso

    2015-01-01

    Full Text Available Introduction. The management of obstructive sleep apnea (OSA in patients who cannot afford a continuous positive airway pressure (CPAP device is challenging. In this study we compare time to CPAP procurement in three groups of patients diagnosed with OSA: uninsured subsidized by a humanitarian grant (Group 1, uninsured unsubsidized (Group 2, and those with Medicare or Medicaid (Group 3. We evaluate follow-up and adherence in Group 1. We hypothesize that additional factors, rather than just the ability to obtain CPAP, may uniquely affect follow-up and adherence in uninsured patients. Methods. 30 patients were in Groups 1 and 2, respectively. 12 patients were in Group 3. Time of CPAP procurement from OSA diagnosis to CPAP initiation was assessed in all groups. CPAP adherence data was collected for Group 1 patients at 1, 3, 6, and 9 months. Results. There were no significant differences between groups in gender, age, body mass index, or apnea hypopnea index. The mean time to procurement in Group 1 was shorter compared to Group 2 but not significant. Compared to both Group 1 and Group 2, Group 3 patients had significantly shorter times to device procurement. Conclusion. Time to procurement of CPAP was significantly shorter in those with Medicaid/Medicare insurance compared to the uninsured.

  4. Determinants of compliance with nasal continuous positive airway pressure treatment applied in a community setting.

    Science.gov (United States)

    Ball, E M.; Banks, M B.

    2001-05-01

    Objectives: To assess determinants of nasal continuous positive airway pressure (CPAP) compliance when applied in a community setting.Background: One-third of obstructive sleep apnea patients eventually refuse CPAP therapy. Treatment outcomes may be improved by identifying predictors of CPAP failure, including whether management by primary care physicians without sleep consultation affects results.Methods: Polysomnogram, chart review, and questionnaire results for regular CPAP users (n=123) were compared with those returning the CPAP machine (n=26).Results: Polysomnographic data and the presence of multiple sleep disorders were only modestly predictive of CPAP compliance. Striking differences in questionnaire responses separated CPAP users from non-users, who reported less satisfaction with all phases of their diagnosis and management. Rates of CPAP use were not significantly different between patients managed solely by their primary care physician or by a sleep consultant.Conclusions: Polysomnographic findings are unlikely to identify eventual CPAP non-compliers in a cost-effective fashion. Improvements in sleep apnea management may result from addressing the role of personality factors and multiple sleep disorders in determining compliance. In this practice setting, management by primary care physicians did not significantly degrade CPAP compliance.

  5. Continuous Positive Airway Pressure: Is it a route for infection in those with Obstructive Sleep Apnoea?

    Directory of Open Access Journals (Sweden)

    Liam Mercieca

    Full Text Available Introduction: Continuous positive airway pressure (CPAP is the standard treatment for obstructive sleep apnoea (OSA, with limited data about the prevalence of respiratory infections and microbial colonization in these patients. Objectives: The aim of this study was to determine if CPAP use is associated with respiratory infections and to identify the organisms that colonize or infect these patients. Method: A retrospective, case-controlled study in patients diagnosed with OSA was carried out. 137 patients were recruited and interviewed using a questionnaire. A nasal swab was taken from each patient. Patients using CPAP machines had swabs taken from masks and humidifiers. Results: 66 (48.2% patients received CPAP treatment with 60.6% of them having a heated humidifier. 78.8% were male, with the majority using a full face mask (63.6%. No significant difference was seen in the prevalence of rhinosinusitis, lower respiratory tract infections and hospital admissions for pneumonia between CPAP and non-CPAP treated patients. The presence of a humidifier did not influence the prevalence of infections. Commensal flora was predominantly cultured from nasal swabs from both patient groups. Coagulase Negative Staphylococci and Diphtheroids were the main organisms cultured from masks and humidifiers respectively. Conclusions: This study shows that the use of CPAP, choice of mask and humidifier have no significant impact on the prevalence of infections and micro-organisms isolated. This is very reassuring to the physician prescribing CPAP therapy and users.

  6. Improvement in Physical Activity in Persons With Obstructive Sleep Apnea Treated With Continuous Positive Airway Pressure.

    Science.gov (United States)

    Jean, Raymonde E; Duttuluri, Manideep; Gibson, Charlisa D; Mir, Sadaf; Fuhrmann, Katherine; Eden, Edward; Supariwala, Azhar

    2017-03-01

    Exercise improves sleep quality, yet people with untreated obstructive sleep apnea (OSA) may engage in less physical activity (PA) due to fatigue and daytime sleepiness. We examined changes in PA and sleep quality before and after treatment with continuous positive airway pressure (CPAP) in OSA patients. In this prospective longitudinal study, persons with a primary diagnosis of OSA were enrolled at a community-based hospital in New York City. At 3 time intervals pre- and post-CPAP (3-8 months), we measured sleep quality using validated questionnaires, perceived PA using the International Physical Activity Questionnaire (IPAQ), and actual PA using pedometer steps per day. We sought to investigate how CPAP use and changes in sleep quality impacted the number of steps taken, as recorded in pedometer steps. In total, 62 patients were enrolled in the study from March 2012 to July 2014. In all, patients averaged 53 years of age, and 26 patients (42%) were female. Among all participants, 86% of persons had moderate to severe sleep apnea (AHI ≥15). Approximately 73% of participants were compliant with CPAP use. Poor sleep quality correlated with lower actual PA (P = .004) at baseline. At 3 and 7 months, there was significant improvement in sleep quality (Δ -2.63 ± 3.4 and Δ -3.5 ± 3.8; P improvement in sleep quality and actual PA.

  7. The Role of Continuous Positive Airway Pressure Therapy in the Management of Respiratory Distress in Extremely Premature Infants

    OpenAIRE

    Sekar, Kris

    2006-01-01

    The use of mechanical ventilation for the treatment of respiratory distress syndrome (RDS) in low birth weight infants may cause barotrauma, volutrauma, and chronic lung disease. Different continuous positive airway pressure (CPAP) delivery systems exist, each with its own practical and clinical advantages and disadvantages. CPAP can be used as either a primary or an adjunctive respiratory support for RDS. Research demonstrates that CPAP decreases the incidence of respiratory failure after ex...

  8. The protracted demise of medical technology. The case of intermittent positive pressure breathing.

    Science.gov (United States)

    Duffy, S Q; Farley, D E

    1992-08-01

    In this study, the effects of hospital, staff, and patient characteristics on the rates of use and abandonment of an outmoded medical technology, intermittent positive pressure breathing (IPPB) are analyzed. The study focuses specifically on the use of IPPB to treat inpatients with chronic obstructive pulmonary disease in a national sample of more than 500 community hospitals from 1980 to 1987. Cross-sectionally, hospitals with shorter case-mix-adjusted lengths of stay, private nonprofit or investor-owned hospitals, and hospitals located outside of the north central United States were more likely to abandon IPPB by 1980. Teaching status, location, ownership, volume, and source of payment all appeared to affect rates of IPPB use in 1980. The longitudinal analysis examines both the probability a hospital abandoned IPPB and declines in rates of IPPB use over the study period, conditioned on the availability of IPPB in 1980. The results show that changes in the characteristics of hospitals, patients, and physicians all help to explain variations in the abandonment of IPPB. These findings contrast with previous studies of technological change, which find hospital size to be the most important variable. Size is important in explaining the rate of use in 1980, but it has no effect on the rate of decline in use or abandonment after 1980. In general, the analysis demonstrates that a combination of factors, economic incentives as well as information, contribute to the abandonment of outmoded medical technologies. Given the surprisingly long time periods required for this process to occur, the analysis underscores the need to strengthen financial incentives that encourage appropriate medical decisions and to disseminate information about the efficacy of specific procedures more widely and effectively.

  9. The Effect of Sleep Disordered Breathing on the Outcome of Stroke and Transient Ischemic Attack

    DEFF Research Database (Denmark)

    Birkbak, Johannes; Clark, Alice J; Rod, Naja Hulvej

    2014-01-01

    The primary objective was to systematically review the literature on how sleep disordered breathing (SDB) affects recurrence and death among stroke or transient ischemic attack (TIA) patients. A secondary objective was to evaluate how treatment of SDB with continuous positive airway pressure (CPAP...

  10. Continuous positive airway pressure (CPAP after lung resection: a randomized clinical trial

    Directory of Open Access Journals (Sweden)

    Ligia dos Santos Roceto

    Full Text Available CONTEXT AND OBJECTIVE: Noninvasive mechanical ventilation during the postoperative period (PO following lung resection can restore residual functional capacity, improve oxygenation and spare the inspiratory muscles. The objective of this study was to assess the efficacy of continuous positive airway pressure (CPAP associated with physiotherapy, compared with physiotherapy alone after lung resection. DESIGN AND SETTING: Open randomized clinical trial conducted in the clinical hospital of Universidade Estadual de Campinas. METHOD: Sessions were held in the immediate postoperative period (POi and on the first and second postoperative days (PO1 and PO2, and the patients were reassessed on the discharge day. CPAP was applied for two hours and the pressure adjustment was set between 7 and 8.5 cmH2O. The oxygenation index (OI, Borg scale, pain scale and presence of thoracic drains and air losses were evaluated. RESULTS : There was a significant increase in the OI in the CPAP group in the POi compared to the Chest Physiotherapy (CP group, P = 0.024. In the CP group the OI was significantly lower on PO1 (P = 0,042, than CPAP group. The air losses were significantly greater in the CPAP group in the POi and on PO1 (P = 0.001, P = 0.028, but there was no significant difference between the groups on PO2 and PO3. There was a statistically significant difference between the groups regarding the Borg scale in the POi (P < 0.001, but there were no statistically significant differences between the groups regarding the pain score. CONCLUSION: CPAP after lung resection is safe and improves oxygenation, without increasing the air losses through the drains. CLINICAL TRIAL REGISTRATION: NCT01285648

  11. Impact of heated humidification with automatic positive airway pressure in obstructive sleep apnea therapy.

    Science.gov (United States)

    Salgado, Sara Moreira da Silva Trindade; Boléo-Tomé, José Pedro Correia Fernandes; Canhão, Cristina Maria Sardinha; Dias, Ana Rita Tavares; Teixeira, Joana Isaac; Pinto, Paula Maria Gonçalves; Caetano, Maria Cristina de Brito Eusébio Bárbara Prista

    2008-09-01

    To study the impact that heated humidification instituted in the beginning of automatic positive airway pressure (APAP) therapy has on compliance with and the side effects of the treatment. Thirty-nine treatment-naïve patients with obstructive sleep apnea were randomized into two groups to receive APAP using one of two modalities: with heated humidification (APAPwith group); and without heated humidification (APAPw/o group).Patients were evaluated at 7 and 30 days after APAP initiation. The following parameters were analyzed: compliance with treatment (mean number of hours/night); side effects (dry nose or mouth, nasal obstruction and rhinorrhea); daytime sleepiness (Epworth sleepiness scale score) and subjective comfort (visual analog scale score). Patients were also evaluated in terms of residual apnea-hypopnea index (AHI), as well as mean pressures and leaks registered in the ventilators. There were no differences between the two groups in terms of mean age (APAPwith: 57.4 +/- 9.2; APAPw/o: 56.5 +/- 10.7 years), AHI (APAPwith: 28.1 +/- 14.0; APAPw/o: 28.8 +/- 20.5 events/hour of sleep), baseline Epworth score (APAPwith: 11.2 +/- 5.8; APAPw/o: 11.9 +/- 6.3) and initial nasal symptoms. Compliance was similar in both groups (APAPwith: 5.3 +/- 2.4; APAPw/o: 5.2 +/- 2.3 h/night). There were no differences in any of the other parameters analyzed. The introduction of heated humidification at the beginning of APAP therapy provided no advantage in terms of treatment compliance or side effects of treatment.

  12. Effects of Continuous Positive Airway Pressure on Cognitive and Functional Outcome of Stroke Patients with Obstructive Sleep Apnea : A Randomized Controlled Trial

    NARCIS (Netherlands)

    Aaronson, J.A.; Hofman, W.F.; van Bennekom, C.A.M.; van Bezeij, T.; van den Aardweg, J.G.; Groet, E.; Kylstra, W.A.; Schmand, B.

    2016-01-01

    STUDY OBJECTIVES: Obstructive sleep apnea (OSA) in stroke patients is associated with worse functional and cognitive status during inpatient rehabilitation. We hypothesized that a four-week period of continuous positive airway pressure (CPAP) treatment would improve cognitive and functional

  13. Symptoms of insomnia among patients with obstructive sleep apnea before and after two years of positive airway pressure treatment.

    Science.gov (United States)

    Björnsdóttir, Erla; Janson, Christer; Sigurdsson, Jón F; Gehrman, Philip; Perlis, Michael; Juliusson, Sigurdur; Arnardottir, Erna S; Kuna, Samuel T; Pack, Allan I; Gislason, Thorarinn; Benediktsdóttir, Bryndis

    2013-12-01

    To assess the changes of insomnia symptoms among patients with obstructive sleep apnea (OSA) from starting treatment with positive airway pressure (PAP) to a 2-y follow-up. Longitudinal cohort study. Landspitali--The National University Hospital of Iceland. There were 705 adults with OSA who were assessed prior to and 2 y after starting PAP treatment. PAP treatment for OSA. All patients underwent a medical examination along with a type 3 sleep study and answered questionnaires on health and sleep before and 2 y after starting PAP treatment. The change in prevalence of insomnia symptoms by subtype was assessed by questionnaire and compared between individuals who were using or not using PAP at follow-up. Symptoms of middle insomnia were most common at baseline and improved significantly among patients using PAP (from 59.4% to 30.7%, P insomnia tended to persist regardless of PAP treatment, and symptoms of late insomnia were more likely to improve among patients not using PAP. Patients with symptoms of initial and late insomnia at baseline were less likely to adhere to PAP (odds ratio [OR] 0.56, P = 0.007, and OR 0.53, P insomnia. Symptoms of initial and late insomnia, however, tended to persist regardless of positive airway pressure treatment and had a negative effect on adherence. Targeted treatment for insomnia may be beneficial for patients with obstructive sleep apnea comorbid with insomnia and has the potential to positively affect adherence to positive airway pressure.

  14. A mechanical design principle for tissue structure and function in the airway tree.

    Science.gov (United States)

    LaPrad, Adam S; Lutchen, Kenneth R; Suki, Béla

    2013-01-01

    With every breath, the dynamically changing mechanical pressures must work in unison with the cells and soft tissue structures of the lung to permit air to efficiently traverse the airway tree and undergo gas exchange in the alveoli. The influence of mechanics on cell and tissue function is becoming apparent, raising the question: how does the airway tree co-exist within its mechanical environment to maintain normal cell function throughout its branching structure of diminishing dimensions? We introduce a new mechanical design principle for the conducting airway tree in which mechanotransduction at the level of cells is driven to orchestrate airway wall structural changes that can best maintain a preferred mechanical microenvironment. To support this principle, we report in vitro radius-transmural pressure relations for a range of airway radii obtained from healthy bovine lungs and model the data using a strain energy function together with a thick-walled cylinder description. From this framework, we estimate circumferential stresses and incremental Young's moduli throughout the airway tree. Our results indicate that the conducting airways consistently operate within a preferred mechanical homeostatic state, termed mechanical homeostasis, that is characterized by a narrow range of circumferential stresses and Young's moduli. This mechanical homeostatic state is maintained for all airways throughout the tree via airway wall dimensional and mechanical relationships. As a consequence, cells within the airway walls throughout the airway tree experience similar oscillatory strains during breathing that are much smaller than previously thought. Finally, we discuss the potential implications of how the maintenance of mechanical homeostasis, while facilitating healthy tissue-level alterations necessary for maturation, may lead to airway wall structural changes capable of chronic asthma.

  15. A mechanical design principle for tissue structure and function in the airway tree.

    Directory of Open Access Journals (Sweden)

    Adam S LaPrad

    Full Text Available With every breath, the dynamically changing mechanical pressures must work in unison with the cells and soft tissue structures of the lung to permit air to efficiently traverse the airway tree and undergo gas exchange in the alveoli. The influence of mechanics on cell and tissue function is becoming apparent, raising the question: how does the airway tree co-exist within its mechanical environment to maintain normal cell function throughout its branching structure of diminishing dimensions? We introduce a new mechanical design principle for the conducting airway tree in which mechanotransduction at the level of cells is driven to orchestrate airway wall structural changes that can best maintain a preferred mechanical microenvironment. To support this principle, we report in vitro radius-transmural pressure relations for a range of airway radii obtained from healthy bovine lungs and model the data using a strain energy function together with a thick-walled cylinder description. From this framework, we estimate circumferential stresses and incremental Young's moduli throughout the airway tree. Our results indicate that the conducting airways consistently operate within a preferred mechanical homeostatic state, termed mechanical homeostasis, that is characterized by a narrow range of circumferential stresses and Young's moduli. This mechanical homeostatic state is maintained for all airways throughout the tree via airway wall dimensional and mechanical relationships. As a consequence, cells within the airway walls throughout the airway tree experience similar oscillatory strains during breathing that are much smaller than previously thought. Finally, we discuss the potential implications of how the maintenance of mechanical homeostasis, while facilitating healthy tissue-level alterations necessary for maturation, may lead to airway wall structural changes capable of chronic asthma.

  16. Effectiveness of prehospital continuous positive airway pressure in the management of acute pulmonary edema.

    Science.gov (United States)

    Hubble, Michael W; Richards, Michael E; Jarvis, Roger; Millikan, Tori; Young, Dwayne

    2006-01-01

    To compare the effectiveness of continuous positive airway pressure (CPAP) with standard pharmacologic treatment in the management of prehospital acute pulmonary edema. Using a nonrandomized control group design, all consecutive patients presenting to two participating emergency medical services (EMS) systems with a field impression of acute pulmonary edema between July 1, 2004, and June 30, 2005, were included in the study. The control EMS system patients received standard treatment with oxygen, nitrates, furosemide, morphine, and, if indicated, endotracheal intubation. The intervention EMS system patients received CPAP via face mask at 10 cm H2O in addition to standard therapy. Ninety-five patients received standard therapy, and 120 patients received CPAP and standard therapy. Intubation was required in 8.9% of CPAP-treated patients compared with 25.3% in the control group (p = 0.003), and mortality was lower in the CPAP group than in the control group (5.4% vs. 23.2%; p = 0.000). When compared with the control group, the CPAP group had more improvement in respiratory rate (-4.55 vs. -1.81; p = 0.001), pulse rate (-4.77 vs. 0.82; p = 0.013), and dyspnea score (-2.11 vs. -1.36; p = 0.008). Using logistic regression to control for potential confounders, patients receiving standard treatment were more likely to be intubated (odds ratio, 4.04; 95% confidence interval, 1.64 to 9.95) and more likely to die (odds ratio, 7.48; 95% confidence interval, 1.96 to 28.54) than those receiving standard therapy and CPAP. The prehospital use of CPAP is feasible, may avert the need for endotracheal intubation, and may reduce short-term mortality.

  17. Natural history of treatment-emergent central sleep apnea on positive airway pressure: A systematic review.

    Science.gov (United States)

    Nigam, Gaurav; Riaz, Muhammad; Chang, Edward T; Camacho, Macario

    2018-01-01

    Treatment-emergent central sleep apnea (TECSA) is observed in some patients when they are treated with positive airway pressure (PAP) after significant resolution of the preexisting obstructive events in patients with obstructive sleep apnea. The objective of this study was to systematically review the literature for studies describing the natural history of TECSA. PubMed, Medline, Scopus, Web of Science, and Cochran Library databases were searched through June 29, 2017. Five studies were identified that discussed the natural history of TECSA. TECSA developed in 3.5%-19.8% of PAP-treated patients. Treatment-persistent central sleep apnea (TPCSA), representing protracted periods of PAP therapy-related central apneas, was noted in 14.3%-46.2% of patients with TECSA. Delayed-TECSA (D-TECSA) represents an anomalous TECSA entity appearing weeks to months after initial PAP therapy. D-TECSA was observed in 0.7%-4.2% of OSA patients undergoing PAP treatment (after at least 1 month). In patients with TECSA, a higher apnea-hypopnea index (AHI) and central apnea index at their baseline study or a higher residual AHI at their titration study may be associated with an increased likelihood of conversion to TPCSA. Overall, TECSA developed in 3.5%-19.8% of PAP-treated patients with OSA. The vast majority will experience complete resolution of central apneas over a few weeks to months. Unfortunately, about a third of patients with TECSA may continue to exhibit persistence of central sleep apnea on reevaluation. A small proportion may experience D-TECSA after few weeks to several months of initial exposure to PAP therapy.

  18. Plasma apelin levels in obstructive sleep apnea and the effect of continuous positive airway pressure therapy.

    Science.gov (United States)

    Henley, David E; Buchanan, Fiona; Gibson, Rosemary; Douthwaite, Jennie A; Wood, Susan A; Woltersdorf, Wolfram W; Catterall, James R; Lightman, Stafford L

    2009-10-01

    Apelin is a peptide hormone with cardiovascular and glucose homeostasis properties, and obstructive sleep apnea (OSA) is complicated by cardiovascular and metabolic comorbidities. Plasma apelin has not been previously assessed in OSA. We investigated the response of plasma apelin to a 2-h 75 g oral glucose tolerance test (OGTT) and the effect of 3 months compliant continuous positive airway pressure (CPAP) therapy in 15 obese males with newly diagnosed OSA. Plasma apelin and serum cortisol were recorded 10 minutely, while serum insulin and glucose were measured 30 minutely. Ten subjects had plasma apelin measured at intervals across a 24-h period to investigate for circadian variation in apelin levels, and this was repeated following 3 months compliant CPAP therapy. Fasting (0.342+/-0.038 vs 0.288+/-0.024 ng/ml, P=0.04), 30 min (0.399+/-0.035 vs 0.312+/-0.036 ng/ml, P=0.007) and 120 min (0.402+/-0.030 vs 0.259+/-0.024 ng/ml, P<0.001) apelin levels were reduced following CPAP. The area under curve for apelin OGTT response was lower post-CPAP (44.1+/-3.3 vs 35.8+/-2.3 ng/ml per min, P<0.001). Mean OGTT apelin levels showed a significant treatment effect (P=0.006) and a time effect (P<0.001), and the effect of time was different pre- versus post-CPAP (P=0.005). No significant variability in apelin levels existed across the 24-h period at diagnosis. Lower levels were evident overnight following treatment (P=0.004). Improvements in insulin and glucose parameters and reduced cortisol levels were found post-CPAP. In summary, untreated OSA was associated with elevated plasma apelin levels, altered apelin secretory dynamics in response to oral glucose and lack of an apparent circadian variability, which was restored following CPAP.

  19. Self-Efficacy and Short-Term Adherence to Continuous Positive Airway Pressure Treatment in Children.

    Science.gov (United States)

    Xanthopoulos, Melissa S; Kim, Ji Young; Blechner, Michael; Chang, Ming-Yu; Menello, Mary Kate; Brown, Christina; Matthews, Edward; Weaver, Terri E; Shults, Justine; Marcus, Carole L

    2017-07-01

    Infants, children, and adolescents are increasingly being prescribed continuous positive airway pressure (CPAP) for treatment of obstructive sleep apnea syndrome (OSAS), yet adherence is often poor. The purpose of this study was to examine the relationship between caregiver and patient-reported health cognitions about CPAP prior to starting CPAP and CPAP adherence at 1 month. We hypothesized that greater caregiver-reported self-efficacy would be positively associated with CPAP adherence in children. We also evaluated patient-reported self-efficacy and caregiver- and patient-reported risk perception and outcome expectations as they related to adherence, as well as how demographic factors influenced these relationships. A pediatric modification of the Self-Efficacy Measure for Sleep Apnea Questionnaire was administered to children and adolescents with OSAS-prescribed CPAP and their caregivers during the clinical CPAP-initiation visit. The primary outcome variable for adherence was the average total minutes of CPAP usage across all days from the date that CPAP was initiated to 31 days later. Unadjusted ordinary least-square regression showed a significant association between caregiver-reported self-efficacy and adherence (p = .007), indicating that mean daily CPAP usage increased by 48.4 minutes when caregiver-reported self-efficacy increased by one point (95% confidence interval 13.4-83.4 minutes). No other caregiver- or patient-reported cognitive health variables were related to CPAP use. This study indicates that caregiver CPAP-specific self-efficacy is an important factor to consider when starting youth on CPAP therapy for OSAS. Employing strategies to improve caregiver self-efficacy, beginning at CPAP initiation, may promote CPAP adherence. © Sleep Research Society 2017. Published by Oxford University Press on behalf of the Sleep Research Society. All rights reserved. For permissions, please e-mail journals.permissions@oup.com.

  20. Continuous Positive Airway Pressure Adherence In Patients with Obstructive Sleep Apnea & Symptomatic BPH.

    Science.gov (United States)

    Metta, Ramesh V V S; Zaka, Awais; Lee, Vincent C; Mador, M Jeffery

    2017-04-01

    Purpose To determine the short-term and long-term adherence rates with continuous positive airway pressure (CPAP) therapy in sleep apnea patients with benign prostatic hyperplasia (BPH) compared to matched controls. Methods A case-control retrospective analysis was performed in a veterans affairs hospital. All symptomatic patients with BPH (n = 107) ever started on CPAP therapy between 2006 and 2012 were compared with controls matched for severity of sleep apnea (AHI). Adherence measures were obtained at the third and twelfth month visits. The cases included symptomatic BPH patients on active medical therapy. Diuretic use among cases and controls, and severity of nocturia among the cases were also analyzed. Results The mean AHI among cases and controls was 35.6 ± 27.3 and 35.5 ± 31 (p = 0.96). The population was male and predominantly Caucasian. There was no statistically significant difference in percent days CPAP device use ≥4 h. between symptomatic BPH patients and controls at 3-month (51.6 ± 38 vs. 47.2 ± 36; p = 0.43) and 1-year (64 ± 40.5 vs. 64.7 ± 31.3; p = 0.90) visits. The use of diuretics in the cases and controls, and the severity of nocturia in the cases did not influence adherence with CPAP therapy. Conclusions BPH or diuretic use did not affect adherence with CPAP therapy in obstructive sleep apnea. Severity of nocturia did not have any influence on adherence among the cases. BPH, regardless of the severity of nocturia, and diuretic use does not influence CPAP adherence in patients with OSA.

  1. Financial Analysis of an Intensive Pediatric Continuous Positive Airway Pressure Program.

    Science.gov (United States)

    Riley, E Brooks; Fieldston, Evan S; Xanthopoulos, Melissa S; Beck, Suzanne E; Menello, Mary Kate; Matthews, Edward; Marcus, Carole L

    2017-02-01

    Continuous positive airway pressure (CPAP) is effective in treating obstructive sleep apnea in children, but adherence to therapy is low. Our center created an intensive program that aimed to improve adherence. Our objective was to estimate the program's efficacy, cost, revenue and break-even point in a generalizable manner relative to a standard approach. The intensive program included device consignment, behavioral psychology counseling, and follow-up telephone calls. Economic modeling considered the costs, revenue and break-even point. Costs were derived from national salary reports and the Pediatric Health Information System. The 2015 Medicare reimbursement schedule provided revenue estimates. Prior to the intensive CPAP program, only 67.6% of 244 patients initially prescribed CPAP appeared for follow-up visits and only 38.1% had titration polysomnograms. In contrast, 81.4% of 275 patients in the intensive program appeared for follow-up visits (p break-even points would need to be 1.29-2.08 times higher to cover the costs. An intensive CPAP program leads to substantially higher follow-up and CPAP titration rates, but costs are higher. While affordable at our institution due to the local payer mix and revenue, Medicare reimbursement levels would not cover estimated costs. This study highlights the need for enhanced funding for pediatric CPAP programs, due to the special needs of this population and the long-term health risks of suboptimally treated obstructive sleep apnea. © Sleep Research Society 2016. Published by Oxford University Press on behalf of the Sleep Research Society. All rights reserved. For permissions, please e-mail journals.permissions@oup.com.

  2. Treatment of obstructive sleep apnea syndrome with nasal positive airway pressure improves golf performance.

    Science.gov (United States)

    Benton, Marc L; Friedman, Neil S

    2013-12-15

    Obstructive sleep apnea syndrome (OSAS) is associated with impairment of cognitive function, and improvement is often noted with treatment. Golf is a sport that requires a range of cognitive skills. We evaluated the impact of nasal positive airway pressure (PAP) therapy on the handicap index (HI) of golfers with OSAS. Golfers underwent a nocturnal polysomnogram (NPSG) to determine whether they had significant OSAS (respiratory disturbance index > 15). Twelve subjects with a positive NPSG were treated with PAP. HI, an Epworth Sleepiness Scale (ESS), and sleep questionnaire (SQ) were submitted upon study entry. After 20 rounds of golf on PAP treatment, the HI was recalculated, and the questionnaires were repeated. A matched control group composed of non-OSAS subjects was studied to assess the impact of the study construct on HI, ESS, and SQ. Statistical comparisons between pre- and post-PAP treatment were calculated. The control subjects demonstrated no significant change in HI, ESS, or SQ during this study, while the OSAS group demonstrated a significant drop in average HI (11.3%, p = 0.01), ESS, (p = 0.01), and SQ (p = 0.003). Among the more skilled golfers (defined as HI ≤ 12), the average HI dropped by an even greater degree (31.5%). Average utilization of PAP was 91.4% based on data card reporting. Treatment of OSAS with PAP enhanced performance in golfers with this condition. Treatment adherence was unusually high in this study. Non-medical performance improvement may be a strong motivator for selected subjects with OSAS to seek treatment and maximize adherence.

  3. Continuous positive airway pressure improves gait control in severe obstructive sleep apnoea: A prospective study.

    Directory of Open Access Journals (Sweden)

    Sébastien Baillieul

    Full Text Available Severe obstructive sleep apnoea (OSA can lead to neurocognitive alterations, including gait impairments. The beneficial effects of continuous positive airway pressure (CPAP on improving excessive daytime sleepiness and daily functioning have been documented. However, a demonstration of CPAP treatment efficacy on gait control is still lacking. This study aims to test the hypothesis that CPAP improves gait control in severe OSA patients.In this prospective controlled study, twelve severe OSA patients (age = 57.2±8.9 years, body mass index = 27.4±3.1 kg·m-2, apnoea-hypopnoea index = 46.3±11.7 events·h-1 and 10 healthy matched subjects were included. Overground gait parameters were recorded at spontaneous speed and stride time variability, a clinical marker of gait control, was calculated. To assess the role of executive functions in gait and postural control, a dual-task paradigm was applied using a Stroop test as secondary cognitive task. All assessments were performed before and after 8 weeks of CPAP treatment.Before CPAP treatment, OSA patients had significantly larger stride time variability (3.1±1.1% vs 2.1±0.5% and lower cognitive performances under dual task compared to controls. After CPAP treatment, stride time variability was significantly improved and no longer different compared to controls. Cognitive performance under dual task also improved after CPAP treatment.Eight weeks of CPAP treatment improves gait control of severe OSA patients, suggesting morphological and functional cerebral improvements. Our data provide a rationale for further mechanistic studies and the use of gait as a biomarker of OSA brain consequences.

  4. Nasal continuous positive airway pressure (n-CPAP) does not change cardiac output in preterm infants.

    Science.gov (United States)

    Moritz, Barbara; Fritz, Michael; Mann, Christian; Simma, Burkhard

    2008-02-01

    Our objective was to study how invasive mechanical ventilation impairs cardiac output (CO) in children and adults. Although the application of continuous positive airway pressure (CPAP) is widely practiced in neonatal intensive care, its hemodynamic consequences have not yet been investigated. A prospective study to assess the hemodynamic effects was conducted in 21 preterm infants CPAP (n-CPAP). Gestational age was 28.0 +/- 1.9 weeks (mean +/- standard deviation); birthweight, 1000 +/- 238 g; age at study entry, 200 +/- 155 hours; total maintenance fluid, 154 +/- 42 mL/kg/day; and n-CPAP level, 4.4 +/- 0.9 cm H(2)O. None of the infants received inotropic support, and n-CPAP did not cause any significant difference in the parameters measured: stroke volume, 3.1 +/- 1.0 mL (with n-CPAP) versus 3.1 +/- 1.0 mL (without n-CPAP); cardiac output, 487 +/- 156 mL/minute versus 500 +/- 176 mL/minute; left ventricular diastolic diameter, 1.22 +/- 0.15 cm versus 1.24 +/- 0.14 cm; fractional shortening, 0.30 +/- 0.05% versus 0.29 +/- 0.04%; and aortic velocity-time integral, 8.64 +/- 1.80 cm versus 8.70 +/- 1.65 cm. The n-CPAP level did not influence CO; n-CPAP (up to 7 cm H (2)O) has no echocardiographically detectable hemodynamic effect in preterm infants. Our data imply there is no need to withhold n-CPAP support to prevent circulatory compromise in these infants.

  5. Quality Improvement of Nasal Continuous Positive Airway Pressure Therapy in Neonatal Intensive Care Unit.

    Science.gov (United States)

    Chen, Chien-Yi; Chou, An-Kuo; Chen, Yu-Lien; Chou, Hung-Chieh; Tsao, Po-Nien; Hsieh, Wu-Shiun

    2017-06-01

    Nasal continuous positive airway pressure (NCPAP) therapy is widely used in neonates, but the clinical practice varies. However, nursing practice differs among individuals, and an inappropriate application method may delay the respiratory therapy, influence the beneficial effect of NCPAP, and increase complications. We introduced a quality improvement project to expedite the application of NCPAP therapy and decrease the incidence of nasal trauma. A new strategy of mobile NCPAP cart with prepacked fixation kits and a written protocol was implemented from April 2006. All medical staff answered a questionnaire to assess their basic knowledge before and after intensive training. The records of the patients who were treated with NCPAP from October 2005 to November 2006 were reviewed. Fifty-nine medical staff were involved in the project, and their mean score for the questionnaire improved from 69.2 points to 98.3 points after training. From October 2005 to November 2006, 113 infants were recruited in total and 82 of them were admitted after the protocol was implemented. The NCPAP cart dramatically shortened the preparation time (from 520 seconds to 72 seconds) and the application time (from 468 seconds to 200 seconds). The use of the nursing protocol significantly decreased the incidence of nasal trauma in the study population (45.2% vs. 19.6%, p = 0.006), but not in infants with a birth weight of < 1000 g. Risk factors for nasal skin trauma included lower gestational age and birth weight, longer duration of NCPAP use, and lack of standardized nursing care. The mobile NCPAP cart with prepacked fixation kits is a practical way of expediting the initiation of NCPAP therapy. The written nursing protocol decreased the incidence of nasal trauma in infants, except for those with an extremely low birth weight. Copyright © 2016. Published by Elsevier B.V.

  6. Relationship between loss in parenchymal elastic recoil pressure and maximal airway narrowing in subjects with alpha1-antitrypsin deficiency

    NARCIS (Netherlands)

    Cheung, D.; Schot, R.; Zwinderman, A. H.; Zagers, H.; Dijkman, J. H.; Sterk, P. J.

    1997-01-01

    Airway hyperresponsiveness is characterized by an increase in sensitivity and excessive airway narrowing to inhaled bronchoconstrictor stimuli. There is experimental evidence that maximal airway narrowing is related to lung elasticity in normal and asthmatic subjects. We hypothesized that reduced

  7. Features of motivation of the crewmembers in an enclosed space at atmospheric pressure changes during breathing inert gases.

    Science.gov (United States)

    Komarevcev, Sergey

    Since the 1960s, our psychologists are working on experimenting with small groups in isolation .It was associated with the beginning of spaceflight and necessity to study of human behaviors in ways different from the natural habitat of man .Those, who study human behavior especially in isolation, know- that the behavior in isolation markedly different from that in the natural situations. It associated with the development of new, more adaptive behaviors (1) What are the differences ? First of all , isolation is achieved by the fact ,that the group is in a closed space. How experiments show - the crew members have changed the basic personality traits, such as motivation Statement of the problem and methods. In our experimentation we were interested in changing the features of human motivation (strength, stability and direction of motivation) in terms of a closed group in the modified atmosphere pressure and breathing inert gases. Also, we were interested in particular external and internal motivation of the individual in the circumstances. To conduct experimentation , we used an experimental barocomplex GVK -250 , which placed a group of six mans. A task was to spend fifteen days in isolation on barokomplex when breathing oxigen - xenon mixture of fifteen days in isolation on the same complex when breathing oxygen- helium mixture and fifteen days of isolation on the same complex when breathing normal air All this time, the subjects were isolated under conditions of atmospheric pressure changes , closer to what you normally deal divers. We assumed that breathing inert mixtures can change the strength and stability , and with it , the direction and stability of motivation. To check our results, we planned on using the battery of psychological techniques : 1. Schwartz technique that measures personal values and behavior in society, DORS procedure ( measurement of fatigue , monotony , satiety and stress ) and riffs that give the test once a week. Our assumption is

  8. Breathing circuit compliance and accuracy of displayed tidal volume during pressure-controlled ventilation of infants: A quality improvement project.

    Science.gov (United States)

    Glenski, Todd A; Diehl, Carrie; Clopton, Rachel G; Friesen, Robert H

    2017-09-01

    Anesthesia machines have evolved to deliver desired tidal volumes more accurately by measuring breathing circuit compliance during a preuse self-test and then incorporating the compliance value when calculating expired tidal volume. The initial compliance value is utilized in tidal volume calculation regardless of whether the actual compliance of the breathing circuit changes during a case, as happens when corrugated circuit tubing is manually expanded after the preuse self-test but before patient use. We noticed that the anesthesia machine preuse self-test was usually performed on nonexpanded pediatric circuit tubing, and then the breathing circuit was subsequently expanded for clinical use. We aimed to demonstrate that performing the preuse self-test in that manner could lead to incorrectly displayed tidal volume on the anesthesia machine monitor. The goal of this quality improvement project was to change the usual practice and improve the accuracy of displayed tidal volume in infants undergoing general anesthesia. There were four stages of the project: (i) gathering baseline data about the performance of the preuse self-test and using infant and adult test lungs to measure discrepancies of displayed tidal volumes when breathing circuit compliance was changed after the initial preuse self-test; (ii) gathering clinical data during pressure-controlled ventilation comparing anesthesia machine displayed tidal volume with actual spirometry tidal volume in patients less than 10 kg before (machine preuse self-test performed while the breathing circuit was nonexpanded) and after an intervention (machine preuse self-test performed after the breathing circuit was fully expanded); (iii) performing department-wide education to help implement practice change; (iv) gathering postintervention data to determine the prevalence of proper machine preuse self-test. At constant pressure-controlled ventilation through fully expanded circuit tubing, displayed tidal volume was 83

  9. Gel pillow designed specifically for obstructive sleep apnea treatment with continuous positive airway pressure.

    Science.gov (United States)

    Salvaggio, Adriana; Lo Bue, Anna; Isidoro, Serena Iacono; Romano, Salvatore; Marrone, Oreste; Insalaco, Giuseppe

    2016-01-01

    To determine whether the use of a gel pillow with side cutouts designed to accommodate a continuous positive airway pressure (CPAP) mask and reduce head temperature improves the efficacy of and adherence to auto-CPAP therapy. Twenty-three consecutive CPAP-naïve patients with obstructive sleep apnea were enrolled in the study. Patients were given an auto-CPAP machine with an appropriate CPAP mask and were instructed to use CPAP for 15 nights. They were instructed to sleep with their own pillow (the control pillow) from nights 1 to 5 and with either a foam pillow or a gel pillow, both of which had side cutouts, for 5 consecutive nights each, in random order. After night 15, auto-CPAP machine data were downloaded and patients rated their satisfaction with each pillow on a visual analog scale. Twenty-two patients completed the protocol. The pressures administered, residual apnea-hypopnea index, air leaks, and mean duration of CPAP use did not differ among the periods during which each pillow was used. Patients were significantly more satisfied with the gel pillow than with the control pillow and the foam pillow (p = 0.022 and p = 0.004, respectively), their level of satisfaction with the gel pillow correlating significantly with excessive daytime sleepiness (r2 = 0.19; p = 0.0443). Among obstructive sleep apnea patients treated with nasal CPAP, the use of a gel pillow with side cutouts appears to have no impact on treatment effectiveness. Nevertheless, such patients seem to prefer a gel pillow over other types of pillows. Determinar se o uso de um travesseiro de gel com recortes laterais para acomodar a máscara de continuous positive airway pressure (CPAP, pressão positiva contínua nas vias aéreas) e diminuir a temperatura em torno da cabeça melhora a eficácia do tratamento com auto-CPAP e a adesão dos pacientes ao tratamento. Foram incluídos no estudo 23 pacientes consecutivos com apneia obstrutiva do sono que nunca haviam recebido tratamento com CPAP. Os

  10. A multiscale MDCT image-based breathing lung model with time-varying regional ventilation

    Energy Technology Data Exchange (ETDEWEB)

    Yin, Youbing, E-mail: youbing-yin@uiowa.edu [Department of Mechanical and Industrial Engineering, The University of Iowa, Iowa City, IA 52242 (United States); IIHR-Hydroscience and Engineering, The University of Iowa, Iowa City, IA 52242 (United States); Department of Radiology, The University of Iowa, Iowa City, IA 52242 (United States); Choi, Jiwoong, E-mail: jiwoong-choi@uiowa.edu [Department of Mechanical and Industrial Engineering, The University of Iowa, Iowa City, IA 52242 (United States); IIHR-Hydroscience and Engineering, The University of Iowa, Iowa City, IA 52242 (United States); Hoffman, Eric A., E-mail: eric-hoffman@uiowa.edu [Department of Radiology, The University of Iowa, Iowa City, IA 52242 (United States); Department of Biomedical Engineering, The University of Iowa, Iowa City, IA 52242 (United States); Department of Internal Medicine, The University of Iowa, Iowa City, IA 52242 (United States); Tawhai, Merryn H., E-mail: m.tawhai@auckland.ac.nz [Auckland Bioengineering Institute, The University of Auckland, Auckland (New Zealand); Lin, Ching-Long, E-mail: ching-long-lin@uiowa.edu [Department of Mechanical and Industrial Engineering, The University of Iowa, Iowa City, IA 52242 (United States); IIHR-Hydroscience and Engineering, The University of Iowa, Iowa City, IA 52242 (United States)

    2013-07-01

    A novel algorithm is presented that links local structural variables (regional ventilation and deforming central airways) to global function (total lung volume) in the lung over three imaged lung volumes, to derive a breathing lung model for computational fluid dynamics simulation. The algorithm constitutes the core of an integrative, image-based computational framework for subject-specific simulation of the breathing lung. For the first time, the algorithm is applied to three multi-detector row computed tomography (MDCT) volumetric lung images of the same individual. A key technique in linking global and local variables over multiple images is an in-house mass-preserving image registration method. Throughout breathing cycles, cubic interpolation is employed to ensure C{sub 1} continuity in constructing time-varying regional ventilation at the whole lung level, flow rate fractions exiting the terminal airways, and airway deformation. The imaged exit airway flow rate fractions are derived from regional ventilation with the aid of a three-dimensional (3D) and one-dimensional (1D) coupled airway tree that connects the airways to the alveolar tissue. An in-house parallel large-eddy simulation (LES) technique is adopted to capture turbulent-transitional-laminar flows in both normal and deep breathing conditions. The results obtained by the proposed algorithm when using three lung volume images are compared with those using only one or two volume images. The three-volume-based lung model produces physiologically-consistent time-varying pressure and ventilation distribution. The one-volume-based lung model under-predicts pressure drop and yields un-physiological lobar ventilation. The two-volume-based model can account for airway deformation and non-uniform regional ventilation to some extent, but does not capture the non-linear features of the lung.

  11. A multiscale MDCT image-based breathing lung model with time-varying regional ventilation

    Science.gov (United States)

    Yin, Youbing; Choi, Jiwoong; Hoffman, Eric A.; Tawhai, Merryn H.; Lin, Ching-Long

    2012-01-01

    A novel algorithm is presented that links local structural variables (regional ventilation and deforming central airways) to global function (total lung volume) in the lung over three imaged lung volumes, to derive a breathing lung model for computational fluid dynamics simulation. The algorithm constitutes the core of an integrative, image-based computational framework for subject-specific simulation of the breathing lung. For the first time, the algorithm is applied to three multi-detector row computed tomography (MDCT) volumetric lung images of the same individual. A key technique in linking global and local variables over multiple images is an in-house mass-preserving image registration method. Throughout breathing cycles, cubic interpolation is employed to ensure C1 continuity in constructing time-varying regional ventilation at the whole lung level, flow rate fractions exiting the terminal airways, and airway deformation. The imaged exit airway flow rate fractions are derived from regional ventilation with the aid of a three-dimensional (3D) and one-dimensional (1D) coupled airway tree that connects the airways to the alveolar tissue. An in-house parallel large-eddy simulation (LES) technique is adopted to capture turbulent-transitional-laminar flows in both normal and deep breathing conditions. The results obtained by the proposed algorithm when using three lung volume images are compared with those using only one or two volume images. The three-volume-based lung model produces physiologically-consistent time-varying pressure and ventilation distribution. The one-volume-based lung model under-predicts pressure drop and yields un-physiological lobar ventilation. The two-volume-based model can account for airway deformation and non-uniform regional ventilation to some extent, but does not capture the non-linear features of the lung. PMID:23794749

  12. Cost-effectiveness of Out-of-Hospital Continuous Positive Airway Pressure for Acute Respiratory Failure.

    Science.gov (United States)

    Thokala, Praveen; Goodacre, Steve; Ward, Matt; Penn-Ashman, Jerry; Perkins, Gavin D

    2015-05-01

    We determine the cost-effectiveness of out-of-hospital continuous positive airway pressure (CPAP) compared with standard care for adults presenting to emergency medical services with acute respiratory failure. We developed an economic model using a United Kingdom health care system perspective to compare the costs and health outcomes of out-of-hospital CPAP to standard care (inhospital noninvasive ventilation) when applied to a hypothetical cohort of patients with acute respiratory failure. The model assigned each patient a probability of intubation or death, depending on the patient's characteristics and whether he or she had out-of-hospital CPAP or standard care. The patients who survived accrued lifetime quality-adjusted life-years (QALYs) and health care costs according to their age and sex. Costs were accrued through intervention and hospital treatment costs, which depended on patient outcomes. All results were converted into US dollars, using the Organisation for Economic Co-operation and Development purchasing power parities rates. Out-of-hospital CPAP was more effective than standard care but was also more expensive, with an incremental cost-effectiveness ratio of £20,514 per QALY ($29,720/QALY) and a 49.5% probability of being cost-effective at the £20,000 per QALY ($29,000/QALY) threshold. The probability of out-of-hospital CPAP's being cost-effective at the £20,000 per QALY ($29,000/QALY) threshold depended on the incidence of eligible patients and varied from 35.4% when a low estimate of incidence was used to 93.8% with a high estimate. Variation in the incidence of eligible patients also had a marked influence on the expected value of sample information for a future randomized trial. The cost-effectiveness of out-of-hospital CPAP is uncertain. The incidence of patients eligible for out-of-hospital CPAP appears to be the key determinant of cost-effectiveness. Copyright © 2015 American College of Emergency Physicians. Published by Elsevier Inc. All

  13. Acute Effects of Positive Airway Pressure on Functional Mitral Regurgitation in Patients with Systolic Heart Failure

    Directory of Open Access Journals (Sweden)

    Takao Kato

    2017-11-01

    Full Text Available Background: Acute effects of positive airway pressure (PAP [including continuous PAP (CPAP and adaptive servo-ventilation, an advanced form of bi-level PAP] on functional mitral regurgitation (fMR in patients with heart failure (HF with left ventricular (LV systolic dysfunction remain unclear. Thus, whether PAP therapy reduces fMR in such patients with HF was investigated.Methods and Results: Twenty patients with HF and LV systolic dysfunction defined as LV ejection fraction (LVEF <50% (14 men; mean LVEF, 35.0 ± 11.5% with fMR underwent echocardiography during 10-min CPAP (4 and 8 cm H2O and adaptive servo-ventilation. For fMR assessment, MR jet area fraction, defined as the ratio of MR jet on color Doppler to the left atrial area, was measured. The forward stroke volume (SV index (fSVI was calculated from the time-velocity integral, cross-sectional area of the aortic annulus, and body surface area. fMR significantly reduced on CPAP at 8 cm H2O (0.30 ± 0.12 and adaptive servo-ventilation (0.29 ± 0.12, compared with the baseline phase (0.37 ± 0.12 and CPAP at 4 cm H2O (0.34 ± 0.12 (P < 0.001. The fSVI did not change in any of the PAP sessions (P = 0.888. However, significant differences in fSVI responses to PAP were found between sexes (P for interaction, 0.006, with a significant reduction in fSVI in women (P = 0.041 and between patients with baseline fSVI ≥ and < the median value (27.8 ml/m2, P for interaction, 0.018, with a significant fSVI reduction in patients with high baseline fSVI (P = 0.028. In addition, significant differences were found in fSVI responses to PAP between patients with LV end-systolic volume (LVESV index ≥ and < the median value (62.0 ml/m2, P for interaction, 0.034, with a significant fSVI increase in patients with a high LVESV index (P = 0.023.Conclusion: In patients with HF, LV systolic dysfunction, and fMR, PAP can alleviate fMR without any overall changes in forward SV. However, MR alleviation due to PAP

  14. Improvement in headaches with continuous positive airway pressure for obstructive sleep apnea: a retrospective analysis.

    Science.gov (United States)

    Johnson, Karin G; Ziemba, Alexis M; Garb, Jane L

    2013-02-01

    We aimed to identify clinical features in patients with severe headaches that predicted obstructive sleep apnea (OSA) and determine clinical and sleep study characteristics that predicted headache improvement with continuous positive airway pressure (CPAP). Many patients with headaches complain of sleep symptoms and have OSA. There is often improvement of headaches with CPAP treatment. We conducted a retrospective chart review of all patients referred to adult neurology clinic for headaches and sent for polysomnography between January 2008 and December 2009. Follow-up ranged from 18 to 42 months. Eighty-two headache patients (70 females, 12 males) were studied. Mean age was 45±13 years (females 45±13, males 43±11) and mean body mass index was 32±9. Headache types included 17% chronic migraine without aura, 22% episodic migraine without aura, 32% migraine with aura, 21% tension-type headache, 6% chronic post-traumatic headache, 11% medication overuse headache, and 7% other types. All patients were receiving standard treatment for their headaches by their neurologist. Fifty-two patients (63%) had OSA. Increasing age, female gender, and chronic migraine without aura were predictive of OSA. Of the patients with OSA, 33 (63%) used CPAP and 27 (82%) were adherent to CPAP. Headache improvement was reported by 40 patients (49%) due to either standard medical therapy or CPAP. Patients with OSA who were CPAP adherent (21/27) were more likely to have improvement in headaches than patients intolerant of CPAP (2/6), those that did not try CPAP (8/19), and those who did not have OSA (16/30) (P=.045). Of the 33 patients who used CPAP, 13 reported improvement in headaches specifically due to CPAP therapy and 10 additional patients noted benefit in sleep symptoms. The presence of witnessed apneas (P=.045) and male gender (P=.021) predicted improvement in headaches due to CPAP. Headache patients should be evaluated for the presence of OSA. Treating OSA improves headaches in some

  15. Effects of a short course of eszopiclone on continuous positive airway pressure adherence: a randomized trial.

    Science.gov (United States)

    Lettieri, Christopher J; Shah, Anita A; Holley, Aaron B; Kelly, William F; Chang, Audrey S; Roop, Stuart A

    2009-11-17

    Adherence to short-term continuous positive airway pressure (CPAP) may predict long-term use. Unfortunately, initial CPAP intolerance may lead to poor adherence or abandonment of therapy. To determine whether a short course of eszopiclone at the onset of therapy improves long-term CPAP adherence more than placebo in adults with obstructive sleep apnea. Parallel randomized, placebo-controlled trial from March 2007 to December 2008. Randomization, maintained and concealed centrally by pharmacy personnel, was computer-generated using fixed blocks of 10. Referring physicians, investigators, and patients were blinded to the treatment assignment until after the final data were collected. (ClinicalTrials.gov registration number: NCT00612157). Academic sleep disorder center. 160 adults (mean age, 45.7 years [SD, 7.3]; mean apnea-hypopnea index, 36.9 events/h [SD, 23]) with newly diagnosed obstructive sleep apnea initiating CPAP. Eszopiclone, 3 mg (n = 76), or matching placebo (n = 78) for the first 14 nights of CPAP. Use of CPAP was measured weekly for 24 weeks. Adherence to CPAP (primary outcome) and the rate of CPAP discontinuation and improvements in symptoms (secondary outcomes) were compared. Follow-up at 1, 3, and 6 months was completed by 150, 136, and 120 patients, respectively. Patients in the eszopiclone group used CPAP for 20.8% more nights (95% CI, 7.2% to 34.4%; P = 0.003), 1.3 more hours per night for all nights (CI, 0.4 to 2.2 hours; P = 0.005), and 1.1 more hours per night of CPAP use (CI, 0.2 to 2.1 hours; P = 0.019). The hazard ratio for discontinuation of CPAP was 1.90 (CI, 1.1 to 3.4; P = 0.033) times higher in the placebo group. Side effects were reported in 7.1% of patients and did not differ between groups. Patients had severe obstructive sleep apnea treated at a specialized sleep center with frequent follow-up; results may not be generalizable to different settings. Patients' tolerance to CPAP and their reasons for discontinuation were not assessed

  16. A Randomized Trial of Low-Flow Oxygen versus Nasal Continuous Positive Airway Pressure in Preterm Infants

    DEFF Research Database (Denmark)

    Heiring, Christian; Steensberg, Jesper; Bjerager, Mia

    2015-01-01

    BACKGROUND: Nasal continuous positive airway pressure (nCPAP) stabilizes the residual volume and may decrease the risk of 'atelectotrauma', potentially promoting lung development in neonates. OBJECTIVES: To assess whether replacing nCPAP by low-flow O2 by nasal cannula affects lung function...... the a/A pO2 ratio or weight gain negatively. Thus, prolonged nCPAP seems not to have a positive effect on lung function at 28 days of life and replacement by low-flow O2 could reduce the cost of equipment and increase the ease of nursing....

  17. Effects of continuous positive airway pressure on energy intake in obstructive sleep apnea: A pilot sham-controlled study

    OpenAIRE

    Shechter, Ari; Kovtun, Kyle; St-Onge, Marie-Pierre

    2016-01-01

    Obesity is among the leading risk factors for obstructive sleep apnea (OSA). A reciprocal relationship between obesity and OSA has been proposed, which may be due to excessive food intake. We conducted a pilot study to test the effects of continuous positive airway pressure (CPAP) on energy intake (EI) in OSA patients using a sham-controlled crossover design. In-laboratory total daily EI was assessed after 2 mo of active and sham CPAP. Four men were enrolled (age ± SEM: 51.8 ± 2.1 y; body mas...

  18. Anticholinergic treatment in airways diseases.

    LENUS (Irish Health Repository)

    Flynn, Robert A

    2009-10-01

    The prevalence of chronic airways diseases such as chronic obstructive pulmonary disease and asthma is increasing. They lead to symptoms such as a cough and shortness of breath, partially through bronchoconstriction. Inhaled anticholinergics are one of a number of treatments designed to treat bronchoconstriction in airways disease. Both short-acting and long-acting agents are now available and this review highlights their efficacy and adverse event profile in chronic airways diseases.

  19. Sleep-disordered breathing in epilepsy: epidemiology, mechanisms, and treatment.

    Science.gov (United States)

    Sivathamboo, Shobi; Perucca, Piero; Velakoulis, Dennis; Jones, Nigel C; Goldin, Jeremy; Kwan, Patrick; O'Brien, Terence J

    2018-04-01

    Epilepsy is a group of neurological conditions in which there is a pathological and enduring predisposition to generate recurrent seizures. Evidence over the last few decades suggests that epilepsy may be associated with increased sleep-disordered breathing, which may contribute towards sleep fragmentation, daytime somnolence, reduced seizure control, and cardiovascular-related morbidity and mortality. Chronic sleep-disordered breathing can result in loss of gray matter and cause deficits to memory and global cognitive function. Sleep-disordered breathing is a novel and independent predictor of sudden cardiac death and, as such, may be involved in the mechanisms leading to sudden unexpected death in epilepsy. Despite this, the long-term consequences of sleep-disordered breathing in epilepsy remain unknown, and there are no guidelines for screening or treating this population. There is currently insufficient evidence to indicate continuous positive airway pressure (CPAP) for the primary or secondary prevention of cardiovascular disease, and recent evidence has failed to show any reduction of fatal or nonfatal cardiovascular endpoints. Treatment of sleep-disordered breathing may potentially improve seizure control, daytime somnolence, and neurocognitive outcomes, but few studies have examined this relationship. In this review, we examine sleep-disordered breathing in epilepsy, and discuss the potential effect of epilepsy treatments. We consider the role of CPAP and other interventions for sleep-disordered breathing and discuss their implications for epilepsy management.

  20. Negative pressure pulmonary oedema following use of ProSeal LMA

    Directory of Open Access Journals (Sweden)

    Richa Jain

    2013-01-01

    Full Text Available Negative pressure pulmonary oedema (NPPO is a life threatening condition, manifested due to upper airway obstruction in a spontaneously breathing patient. Upper airway obstruction caused by classic laryngeal mask airway (cLMA and ProSeal laryngeal mask airway (PLMA has been reported, and NPPO has also been reported following the use of cLMA. Search of literature did not confirm NPPO following the use of PLMA. We encountered a female patient of NPPO scheduled for incision and drainage of an abscess who had signs of airway obstruction following PLMA insertion. Multiple attempts were made to get patent airway without success. PLMA was replaced with endotracheal tube following which pink frothy secretion appeared in breathing circuit. Patient was managed successfully with ICU care.

  1. Deep breathing exercises with positive expiratory pressure at a higher rate improve oxygenation in the early period after cardiac surgery--a randomised controlled trial.

    Science.gov (United States)

    Urell, Charlotte; Emtner, Margareta; Hedenström, Hans; Tenling, Arne; Breidenskog, Marie; Westerdahl, Elisabeth

    2011-07-01

    In addition to early mobilisation, a variety of breathing exercises are used to prevent postoperative pulmonary complications after cardiac surgery. The optimal duration of the treatment is not well evaluated. The aim of this study was to determine the effect of 30 versus 10 deep breaths hourly, while awake, with positive expiratory pressure on oxygenation and pulmonary function the first days after cardiac surgery. A total of 181 patients, undergoing cardiac surgery, were randomised into a treatment group, performing 30 deep breaths hourly the first postoperative days, or into a control group performing 10 deep breaths hourly. The main outcome measurement arterial blood gases and the secondary outcome pulmonary function, evaluated with spirometry, were determined on the second postoperative day. Preoperatively, both study groups were similar in terms of age, SpO(2), forced expiratory volume in 1s and New York Heart Association classification. On the second postoperative day, arterial oxygen tension (PaO(2)) was 8.9 ± 1.7 kPa in the treatment group and 8.1 ± 1.4 kPa in the control group (p = 0.004). Arterial oxygen saturation (SaO(2)) was 92.7 ± 3.7% in the treatment group and 91.1 ± 3.8% in the control group (p = 0.016). There were no differences in measured lung function between the groups or in compliance to the breathing exercises. Compliance was 65% of possible breathing sessions. A significantly increased oxygenation was found in patients performing 30 deep breaths the first two postoperative days compared with control patients performing 10 deep breaths hourly. These results support the implementation of a higher rate of deep breathing exercises in the initial phase after cardiac surgery. Copyright © 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

  2. Dispersal kinetics of deuterated water in the lungs and airways following mouth inhalation: real-time breath analysis by flowing afterglow mass spectrometry (FA-MS)

    Czech Academy of Sciences Publication Activity Database

    Tan, B. K.; Smith, D.; Španěl, Patrik; Davies, S. J.

    2010-01-01

    Roč. 4, č. 1 (2010), 017109 ISSN 1752-7155 Institutional research plan: CEZ:AV0Z40400503 Keywords : mass spectrometry * breath analysis * pulmonary-edema Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 1.828, year: 2010

  3. Titration effectiveness of two autoadjustable continuous positive airway pressure devices driven by different algorithms in patients with obstructive sleep apnoea.

    Science.gov (United States)

    Damiani, Mario Francesco; Quaranta, Vitaliano Nicola; Tedeschi, Ersilia; Drigo, Riccardo; Ranieri, Teresa; Carratù, Pierluigi; Resta, Onofrio

    2013-08-01

    Nocturnal application of continuous positive airway pressure (CPAP) is the standard treatment for patients with obstructive sleep apnoea (OSA). Determination of the therapeutic pressure (CPAP titration) is usually performed by a technician in the sleep laboratory during attended polysomnography. One possible alternative to manual titration is automated titration. Indeed, during the last 15 years, devices have been developed that deliver autoadjustable CPAP (A-CPAP). The aim of the present study was to compare the titration effectiveness of two A-CPAP devices using different flow-based algorithms in patients with OSA. This is a randomized study; 79 subjects underwent two consecutive unattended home A-CPAP titration nights with two different devices (Autoset Resmed; Remstar Auto Respironics); during the third and the fourth night, patients underwent portable monitoring in the sleep laboratory during fixed CPAP at the A-CPAP recommended pressure. Bland Altman plots showed good agreement between the recommended median and maximal pressure levels obtained with the two devices. A significant improvement was observed in all the sleep parameters by both A-CPAP machines to a similar degree. It was observed that the two A-CPAP devices using different algorithms are equally effective in initial titration of CPAP. © 2013 The Authors. Respirology © 2013 Asian Pacific Society of Respirology.

  4. Leukotriene-B4 concentrations in exhaled breath condensate and lung function after thirty minutes of breathing technically dried compressed air.

    Science.gov (United States)

    Neubauer, Birger; Struck, Niclas; Mutzbauer, Till S; Schotte, Ulrich; Langfeldt, Norbert; Tetzlaff, Kay

    2002-01-01

    In previous studies it had been shown that leukotriene-B4 [LTB4] concentrations in the exhaled breath mirror the inflammatory activity of the airways if the respiratory tract has been exposed to occupational hazards. In diving the respiratory tract is exposed to cold and dry air and the nasopharynx, as the site of breathing-gas warming and humidification, is bypassed. The aim of the present study was to obtain LTB4-concentrations in the exhaled breath and spirometric data of 17 healthy subjects before and after thirty minutes of technically dried air breathing at normobar ambient pressure. The exhaled breath was collected non-invasively, via a permanently cooled expiration tube. The condensate was measured by a standard enzyme immunoassay for LTB4. Lung function values (FVC, FEV1, MEF 25, MEF 50) were simultaneously obtained by spirometry. The measured pre- and post-exposure LTB4- concentrations as well as the lung function values were in the normal range. The present data gave no evidence for any inflammatory activity in the subjects' airways after thirty minutes breathing technically dried air.

  5. Early nasal continuous positive airway pressure versus INSURE in VLBW neonates

    Directory of Open Access Journals (Sweden)

    Ana Saianda

    2010-09-01

    Full Text Available Background: Evidence suggests the INSURE strategy (INtubate-SURfactant administration and Extubate to nasal continuous positive airway pressure [nCPAP] is superior to mechanical ventilation (MV with rescue surfactant for the management of respiratory distress syndrome (RDS in very low birth weight (VLBW neonates. There is limited data, however, to assess whether INSURE is superior to nCPAP alone. We aimed to compare these two strategies regarding early and late outcomes. Methods: Retrospective cohort study from Jan/2002 to Aug/2008. We included VLBW neonateswith gestational age (GA ≤ 30 weeks registered in the Vermont Oxford Network that used either nCPAP alone (nCPAP group, N = 40, or with INSURE (INSURE group, N = 56. We assessed early (RDS, need for rescue surfactant, and CPAP failure with MV and late outcomes (chronic lung disease of prematurity (CLD, mortality, and composite outcome of mortality and/or CLD. Results: Neonates in the INSURE group had lower mean GA, while other baseline variables were comparable. The proportion of RDS was significantly superior in the nCPAP group (53% vs. 30%; adjusted OR [95% CI] – 0.2 [0.1-0.6]. Therapeutic surfactant was administered to all cases with RDS in the nCPAP group, but to none from the INSURE group. MV was more frequently required in the nCPAP group (11/ 40, 28% vs. 9/ 56, 12%; p = 0.04. No statistically significant differences were found in either of the late outcomes. Conclusion: The use of nCPAP alone in VLBW neonates with GA ≤ 30 weeks may be associated with slightly poorer early outcomes than the INSURE strategy, but there were no significant differences in CLD or mortality. Resumo: Introdução: Pretende-se determinar se a utilização do método INSURE em recém-nascidos de muito baixo peso, com idade gestacional (IG ≤ 30 semanas se associa a menor morbilidade e mortalidade quando comparado com uso de nCPAP isolado. Métodos: Estudo de

  6. Effect of device-guided breathing exercises on blood pressure in hypertensive patients with type 2 diabetes mellitus : A randomized controlled trial

    NARCIS (Netherlands)

    Logtenberg, Susan J.; Kleefstra, Nanne; Houweling, Sebastlaan T.; Groenier, Klaas H.; Bilo, Henk J.

    Objective In patients with type 2 diabetes mellitus (DM2), it is hard to reach treatment objectives for blood pressure (BP) with classical treatment options. Recently, reducing breathing frequency has been advocated as a method to reduce BP. We examined if an electronic device such as Resperate, by

  7. Bubble vs conventional continuous positive airway pressure for prevention of extubation failure in preterm very low birth weight infants: a pilot study.

    Science.gov (United States)

    Yadav, Sucheta; Thukral, Anu; Sankar, M Jeeva; Sreenivas, V; Deorari, Ashok K; Paul, Vinod K; Agarwal, Ramesh

    2012-09-01

    To compare the efficacy of bubble and conventional nasal continuous positive airway pressure (CPAP) in preventing extubation failure (EF) in preterm infants. Infants of gestation ≤32 wk and birth weight <1500 g, ready for initial extubation within first wk of life were randomly allocated to either bubble (n = 16) or conventional (n = 16) CPAP. A standardized protocol was used for extubation. Bubble CPAP was delivered by Fischer and Paykel equipment using short binasal prongs and conventional CPAP was delivered by a ventilator using Argyle short binasal prongs. CPAP was initiated at a pressure of 4-6 cm of H(2)O and FiO(2) of 0.4-0.5 and adjusted to maintain normal saturation (90-93%) and comfortable breathing. Primary outcome was EF, defined as need for mechanical ventilation within 72 h of extubation. Baseline characteristics including birth weight (g; 1027 ± 243 vs. 1018 ± 227; p = 0.83), gestation (wk; 28.7 ± 1.8 vs. 28.4 ± 1.6; p = 0.30), infants <28 wk gestation (6 vs. 7, p = 0.72) were comparable between the two groups. Respiratory distress syndrome was the indication for ventilation in 13 (81%) and 14 (87%) infants on bubble CPAP and conventional CPAP groups respectively. (p = 0.99). There was no difference in the EF rates between the bubble (n = 4) and conventional CPAP (n = 9) groups. (RR 0.49; 95% CI 0.20-1.2; p = 0.14). Median time to extubation failure was also comparable between the two groups (h; median [range]: 29 [14-49] vs. 17 [7-28]; p = 0.35). The possibility that bubble CPAP may be associated with reduced EF as suggested in this pilot study requires further investigation in an adequately powered multicentric study.

  8. Four-Hour Dives with Exercise While Breathing Oxygen Partial Pressure of 1.3 ATM

    National Research Council Canada - National Science Library

    Shykoff, B

    2006-01-01

    ...) or less but does not address the possible accumulation of effects over multiple days. We have conducted experimental four-hour dives with oxygen partial pressure (Po2) of approximately 1.4 atmospheres (atm...

  9. Three-Hour Dives with Exercise While Breathing Oxygen Partial Pressure of 1.3 ATM

    National Research Council Canada - National Science Library

    Shykoff, B

    2007-01-01

    ...) or less but does not address the possible accumulation of effects over multiple days. When we conducted experimental four-hour dives with oxygen partial pressure (Po2) of approximately 1.4 atmospheres (atm...

  10. Combination of intravenous dexmedetomidine with topicalization of airway for placement of double lumen tube in a spontaneously breathing patient of giant lung bullae

    Directory of Open Access Journals (Sweden)

    Vikas Karne

    2016-10-01

    Here we present a patient with giant lung bulla in left lower lobe with severely reduced pulmonary reserves and significant air-trapping posted for VAT assisted bullectomy. Anaesthesia challenges including pathological changes, its effects during induction of anaesthesia, and issues related to placement of double lumen tube in a spontaneously breathing patient are discussed with possible advantages of dexmedetomidine in this special group of patients.

  11. Early application of airway pressure release ventilation may reduce the duration of mechanical ventilation in acute respiratory distress syndrome.

    Science.gov (United States)

    Zhou, Yongfang; Jin, Xiaodong; Lv, Yinxia; Wang, Peng; Yang, Yunqing; Liang, Guopeng; Wang, Bo; Kang, Yan

    2017-11-01

    Experimental animal models of acute respiratory distress syndrome (ARDS) have shown that the updated airway pressure release ventilation (APRV) methodologies may significantly improve oxygenation, maximize lung recruitment, and attenuate lung injury, without circulatory depression. This led us to hypothesize that early application of APRV in patients with ARDS would allow pulmonary function to recover faster and would reduce the duration of mechanical ventilation as compared with low tidal volume lung protective ventilation (LTV). A total of 138 patients with ARDS who received mechanical ventilation for mechanical ventilation from enrollment to day 28. The secondary endpoints included oxygenation, P plat , respiratory system compliance, and patient outcomes. Compared with the LTV group, patients in the APRV group had a higher median number of ventilator-free days {19 [interquartile range (IQR) 8-22] vs. 2 (IQR 0-15); P mechanical ventilation and ICU stay.

  12. Dynamic Characteristics of Mechanical Ventilation System of Double Lungs with Bi-Level Positive Airway Pressure Model

    Directory of Open Access Journals (Sweden)

    Dongkai Shen

    2016-01-01

    Full Text Available In recent studies on the dynamic characteristics of ventilation system, it was considered that human had only one lung, and the coupling effect of double lungs on the air flow can not be illustrated, which has been in regard to be vital to life support of patients. In this article, to illustrate coupling effect of double lungs on flow dynamics of mechanical ventilation system, a mathematical model of a mechanical ventilation system, which consists of double lungs and a bi-level positive airway pressure (BIPAP controlled ventilator, was proposed. To verify the mathematical model, a prototype of BIPAP system with a double-lung simulators and a BIPAP ventilator was set up for experimental study. Lastly, the study on the influences of key parameters of BIPAP system on dynamic characteristics was carried out. The study can be referred to in the development of research on BIPAP ventilation treatment and real respiratory diagnostics.

  13. Effect of continuous positive airway pressure ventilation on prethrombotic state in patients with obstructive sleep apnea-hypopnea syndrome

    International Nuclear Information System (INIS)

    Guo Dianbao; Chen Xiangkun; Sheng Chunyong; Zhang Yingying

    2009-01-01

    To investigate the prethrombotic state (PTS) in patients with obstructive sleep apnea syndrome (OS-AS) and the effect of continuous positive airway pressure ventilation (CPAP) on their PTS, the blood samples of 49 patients with OSAS were taken before treatment and on day 30 after treatment respectively. The platelet aggregation ( PAG), P-selections, endothdlin-1 (ET-1) and plasma vom willebrand factor (vWF) in 49 patients and 42 health controls were detected by radioimmunoassay and enzyme-immunoassay. The results showed that the PAG, P-selections, ET-1 and vWF in patients with OSAS before treatment were significantly higher than those after treatment and in control group (P 0.05). The results indicate that there were PTS in most patients with OSAS before treatment. The activity of platelet could be corrected, and the function of endotheliocyte could be repaired after CPAP treatment. It had certain effect in lightening the clinical symptoms. (authors)

  14. Continuous positive airway pressure (CPAP) to treat respiratory distress in newborns in low- and middle-income countries.

    Science.gov (United States)

    Dewez, Juan Emmanuel; van den Broek, Nynke

    2017-01-01

    Severe respiratory distress is a serious complication common to the three major causes of neonatal mortality and morbidity (prematurity, intra-partum-related hypoxia and infections). In low- and middle-income countries (LMICs), 20% of babies presenting with severe respiratory distress die.Continuous positive airway pressure (CPAP), is an effective intervention for respiratory distress in newborns and widely used in high-income countries. Following the development of simple, safe and relatively inexpensive CPAP devices, there is potential for large-scale implementation in the developing world.In this article, we describe existing CPAP systems and present a review of the current literature examining the effectiveness of CPAP compared to standard care (oxygen) in newborns with respiratory distress. We also discuss the evidence gap which needs to be addressed prior to its integration into health systems in LMICs. © The Author(s) 2016.

  15. Experience of nasal continuous positive airway pressure (cpap) by infant flow driver in a neonatal unit of a developing country

    International Nuclear Information System (INIS)

    Iqbal, A.; Waqar, T.; Safdar, C.A.; Iqbal, T.

    2014-01-01

    Objective: To study the safety and efficacy of nasal continuous positive airways pressure by infant flow drivers in neonates admitted with respiratory problems. Study Design: Quasi-experimental study. Place and Duration of Study: This study was conducted at CMH Lahore from April 2012 to March 2013. Subjects and Methods: All infants who were treated with nasal continuous positive airway pressure (nCPAP) for various indications at neonatal intensive care unit (NICU) of CMH Lahore were evaluated for gestational, age, weight, gender, indications and duration on nCPAP, pre-defined outcomes, complications and length of hospital stay. Efficacy was defined as the ability to manage an infant on nCPAP alone thus avoiding the need for mechanical ventilation. Results: During the study period, 343 neonates were admitted in NICU, forty five neonates were placed on nCPAP. Mean gestational age was 33.85+ 3 weeks. Mean weight was 2043 + 770 grams. Main indications for applying nCPAP were respiratory distress syndrome (48.9%) and neonatal pneumonia (17.8%). Most common complication was abdominal distension (6.7%). Out of 45 infants placed on nCPAP, 32 (71.1%) were managed on nCPAP alone while 13 (28.9%) needed mechanical ventilation after nCPAP failure. Conclusion: Nasal CPAP by an infant flow driver is a useful method to manage respiratory distress in neonates. It reduces the need for mechanical ventilation and can be used as first line respiratory support before mechanical ventilation. (author)

  16. Oral appliance therapy versus nasal continuous positive airway pressure in obstructive sleep apnea: a randomized, placebo-controlled trial on psychological distress

    NARCIS (Netherlands)

    Aarab, Ghizlane; Nikolopoulou, Maria; Ahlberg, Jari; Heymans, Martijn W.; Hamburger, Hans L.; de Lange, Jan; Lobbezoo, Frank

    2017-01-01

    The aim of this randomized placebo-controlled trail was to compare the effects of an objectively titrated mandibular advancement device (MAD) with those of nasal continuous positive airway pressure (nCPAP) and an intraoral placebo device on symptoms of psychological distress in OSA patients. In a

  17. A 64-year old man who sustained many episodes of acute cardiogenic pulmonary edema successfully treated with Boussignac continuous positive airway pressure : A case report

    NARCIS (Netherlands)

    Dieperink, Willem; van der Horst, Iwan C. C.; Nannenberg-Koops, Jaqueline W.; Brouwer, Henk W.; Jaarsma, T.; Nieuwland, Wybe; Zijlstra, Felix; Nijsten, Maarten W. N.

    2007-01-01

    Continuous positive airway pressure (CPAP) is standard treatment for patients with acute cardiogenic pulmonary edema. We describe a patient who had 21 episodes of acute cardiogenic pulmonary edema due to very poor patient compliance. This 64-year old man had end-stage congestive heart failure based

  18. Sexual function and obstructive sleep apnea-hypopnea : A randomized clinical trial evaluating the effects of oral-appliance and continuous positive airway pressure therapy

    NARCIS (Netherlands)

    Hoekema, Aarnoud; Stel, Anna-Lucia; Stegenga, Boudewijn; van der Hoeven, Johannes H.; Wijkstra, Peter J.; van Driel, Mels F.; de Bont, Lambert G. M.

    Introduction. The obstructive sleep apnea-hypopnea syndrome (OSAHS) is associated with sexual dysfunction. Although successful treatment with continuous positive airway pressure (CPAP) has been demonstrated to improve sexual function, the effects of oral-appliance therapy are unknown. Aim. The aims

  19. The effect of obstructive sleep apnea and treatment with continuous positive airway pressure on stroke rehabilitation: rationale, design and methods of the TOROS study

    NARCIS (Netherlands)

    Aaronson, Justine A.; van Bennekom, Coen A. M.; Hofman, Winni F.; van Bezeij, Tijs; van den Aardweg, Joost G.; Groet, Erny; Kylstra, Wytske A.; Schmand, Ben A.

    2014-01-01

    Obstructive sleep apnea is a common sleep disorder in stroke patients. Obstructive sleep apnea is associated with stroke severity and poor functional outcome. Continuous positive airway pressure seems to improve functional recovery in stroke rehabilitation. To date, the effect of continuous positive

  20. The effect of obstructive sleep apnea and treatment with continuous positive airway pressure on stroke rehabilitation: rationale, design and methods of the TOROS study

    NARCIS (Netherlands)

    Aaronson, J.A.; van Bennekom, C.A.M.; Hofman, W.F.; van Bezeij, T.; van den Aardweg, J.G.; Groet, E.; Kylstra, W.A.; Schmand, B.A.

    2014-01-01

    BACKGROUND: Obstructive sleep apnea is a common sleep disorder in stroke patients. Obstructive sleep apnea is associated with stroke severity and poor functional outcome. Continuous positive airway pressure seems to improve functional recovery in stroke rehabilitation. To date, the effect of

  1. All-cause mortality from obstructive sleep apnea in male and female patients with and without continuous positive airway pressure treatment

    DEFF Research Database (Denmark)

    Jennum, Poul; Tønnesen, Philip; Ibsen, Rikke

    2015-01-01

    BACKGROUND: More information is needed about the effect on mortality of continuous positive airway pressure (CPAP) in patients with obstructive sleep apnea (OSA), especially in women. METHODS: We employed a historical cohort study design, using data from 25,389 patients with a diagnosis of OSA...

  2. Effects of Continuous Positive Airway Pressure on Cognitive and Functional Outcome of Stroke Patients with Obstructive Sleep Apnea: A Randomized Controlled Trial

    NARCIS (Netherlands)

    Aaronson, Justine A.; Hofman, Winni F.; van Bennekom, Coen A. M.; van Bezeij, Tijs; van den Aardweg, Joost G.; Groet, Erny; Kylstra, Wytske A.; Schmand, Ben

    2016-01-01

    Obstructive sleep apnea (OSA) in stroke patients is associated with worse functional and cognitive status during inpatient rehabilitation. We hypothesized that a four-week period of continuous positive airway pressure (CPAP) treatment would improve cognitive and functional outcomes. We performed a

  3. Comparison of manual versus automatic continuous positive airway pressure titration and the development of a predictive equation for therapeutic continuous positive airway pressure in Chinese patients with obstructive sleep apnoea.

    Science.gov (United States)

    Luo, Jiaying; Xiao, Sichang; Qiu, Zhihui; Song, Ning; Luo, Yuanming

    2013-04-01

    Whether the therapeutic nasal continuous positive airway pressure (CPAP) derived from manual titration is the same as derived from automatic titration is controversial. The purpose of this study was to compare the therapeutic pressure derived from manual titration with automatic titration. Fifty-one patients with obstructive sleep apnoea (OSA) (mean apnoea/hypopnoea index (AHI) = 50.6 ± 18.6 events/h) who were newly diagnosed after an overnight full polysomnography and who were willing to accept CPAP as a long-term treatment were recruited for the study. Manual titration during full polysomnography monitoring and unattended automatic titration with an automatic CPAP device (REMstar Auto) were performed. A separate cohort study of one hundred patients with OSA (AHI = 54.3 ± 18.9 events/h) was also performed by observing the efficacy of CPAP derived from manual titration. The treatment pressure derived from automatic titration (9.8 ± 2.2 cmH(2)O) was significantly higher than that derived from manual titration (7.3 ± 1.5 cmH(2)O; P titration (54.3 ± 18.9 events/h before treatment and 3.3 ± 1.7 events/h after treatment; P titration pressure derived from REMstar Auto is usually higher than the pressure derived from manual titration. © 2013 The Authors. Respirology © 2013 Asian Pacific Society of Respirology.

  4. Optimal level of continuous positive airway pressure: auto-adjusting titration versus titration with a predictive equation.

    Science.gov (United States)

    Choi, Ji Ho; Jun, Young Joon; Oh, Jeong In; Jung, Jong Yoon; Hwang, Gyu Ho; Kwon, Soon Young; Lee, Heung Man; Kim, Tae Hoon; Lee, Sang Hag; Lee, Seung Hoon

    2013-05-01

    The aims of the present study were twofold. We sought to compare two methods of titrating the level of continuous positive airway pressure (CPAP) - auto-adjusting titration and titration using a predictive equation - with full-night manual titration used as the benchmark. We also investigated the reliability of the two methods in patients with obstructive sleep apnea syndrome (OSAS). Twenty consecutive adult patients with OSAS who had successful, full-night manual and auto-adjusting CPAP titration participated in this study. The titration pressure level was calculated with a previously developed predictive equation based on body mass index and apnea-hypopnea index. The mean titration pressure levels obtained with the manual, auto-adjusting, and predictive equation methods were 9.0 +/- 3.6, 9.4 +/- 3.0, and 8.1 +/- 1.6 cm H2O,respectively. There was a significant difference in the concordance within the range of +/- 2 cm H2O (p = 0.019) between both the auto-adjusting titration and the titration using the predictive equation compared to the full-night manual titration. However, there was no significant difference in the concordance within the range of +/- 1 cm H2O (p > 0.999). When compared to full-night manual titration as the standard method, auto-adjusting titration appears to be more reliable than using a predictive equation for determining the optimal CPAP level in patients with OSAS.

  5. Continuous positive airway pressure reduces blood pressure in patients with obstructive sleep apnea; a systematic review and meta-analysis with 1000 patients.

    Science.gov (United States)

    Schein, Andressa S O; Kerkhoff, Alessandra C; Coronel, Christian C; Plentz, Rodrigo D M; Sbruzzi, Graciele

    2014-09-01

    Obstructive sleep apnea (OSA) may lead to the development of hypertension and therapy with continuous positive airway pressure (CPAP) can promote reduction in blood pressure. The objective of this study is to review systematically the effects of CPAP on blood pressure in patients with OSA. The search was conducted in the following databases, from their beginning until February 2013: MEDLINE, Embase, Cochrane CENTRAL, Lilacs and PEDro. In addition, a manual search was performed on references of published studies. Randomized clinical trials (RCTs) that used CPAP compared with placebo CPAP or subtherapeutic CPAP for treatment of patients with OSA and that evaluated office SBP and DBP and 24-h ambulatory blood pressure were selected. Sixteen RCTs were included among 3409 publications, totaling 1166 patients. The use of CPAP resulted in reductions in office SBP [-3.20  mmHg; 95% confidence interval (CI) -4.67 to -1.72] and DBP (-2.87  mmHg; 95% CI -5.18 to -0.55); in night-time SBP (-4.92  mmHg; 95% CI -8.70 to -1.14); in mean 24-h blood pressure (-3.56  mmHg; 95% CI -6.79 to -0.33), mean night-time blood pressure (-2.56  mmHg; 95% CI -4.43 to -0.68) and 24-h DBP (-3.46  mmHg; 95% CI -6.75 to -0.17). However, no significant change was observed in daytime SBP (-0.74  mmHg; 95% CI -3.90 to 2.41) and daytime DBP (-1.86  mmHg; 95% CI -4.55 to 0.83). Treatment with CPAP promoted significantly but small reductions in blood pressure in individuals with OSA. Further studies should be performed to evaluate the effects of long-term CPAP and the impact on cardiovascular risk.

  6. A novel animal model for hyperdynamic airway collapse.

    Science.gov (United States)

    Tsukada, Hisashi; O'Donnell, Carl R; Garland, Robert; Herth, Felix; Decamp, Malcolm; Ernst, Armin

    2010-12-01

    Tracheobronchomalacia (TBM) is increasingly recognized as a condition associated with significant pulmonary morbidity. However, treatment is invasive and complex, and because there is no appropriate animal model, novel diagnostic and treatment strategies are difficult to evaluate. We endeavored to develop a reliable airway model to simulate hyperdynamic airway collapse in humans. Seven 20-kg male sheep were enrolled in this study. Tracheomalacia was created by submucosal resection of > 50% of the circumference of 10 consecutive cervical tracheal cartilage rings through a midline cervical incision. A silicone stent was placed in the trachea to prevent airway collapse during recovery. Tracheal collapsibility was assessed at protocol-specific time points by bronchoscopy and multidetector CT imaging while temporarily removing the stent. Esophageal pressure and flow data were collected to assess flow limitation during spontaneous breathing. All animals tolerated the surgical procedure well and were stented without complications. One sheep died at 2 weeks because of respiratory failure related to stent migration. In all sheep, near-total forced inspiratory airway collapse was observed up to 3 months postprocedure. Esophageal manometry demonstrated flow limitation associated with large negative pleural pressure swings during rapid spontaneous inhalation. Hyperdynamic airway collapse can reliably be induced with this technique. It may serve as a model for evaluation of novel diagnostic and therapeutic strategies for TBM.

  7. Responses to negative pressure surrounding the neck in anesthetized animals.

    Science.gov (United States)

    Wolin, A D; Strohl, K P; Acree, B N; Fouke, J M

    1990-01-01

    Continuous positive pressure applied at the nose has been shown to cause a decrease in upper airway resistance. The present study was designed to determine whether a similar positive transmural pressure gradient, generated by applying a negative pressure at the body surface around the neck, altered upper airway patency. Studies were performed in nine spontaneously breathing anesthetized supine dogs. Airflow was measured with a pneumotachograph mounted on an airtight muzzle placed over the nose and mouth of each animal. Upper airway pressure was measured as the differential pressure between the extrathoracic trachea and the inside of the muzzle. Upper airway resistance was monitored as an index of airway patency. Negative pressure (-2 to -20 cmH2O) was applied around the neck by using a cuirass extending from the jaw to the thorax. In each animal, increasingly negative pressures were transmitted to the airway wall in a progressive, although not linear, fashion. Decreasing the pressure produced a progressive fall in upper airway resistance, without causing a significant change in respiratory drive or respiratory timing. At -5 cmH2O pressure, there occurred a significant fall in upper airway resistance, comparable with the response of a single, intravenous injection of sodium cyanide (0.5-3.0 mg), a respiratory stimulant that produces substantial increases in respiratory drive. We conclude that upper airway resistance is influenced by the transmural pressure across the airway wall and that such a gradient can be accomplished by making the extraluminal pressure more negative.(ABSTRACT TRUNCATED AT 250 WORDS)

  8. Retrospective, nonrandomized controlled study on autoadjusting, dual-pressure positive airway pressure therapy for a consecutive series of complex insomnia disorder patients

    Directory of Open Access Journals (Sweden)

    Krakow B

    2017-03-01

    Full Text Available Barry Krakow,1–3 Natalia D McIver,1,2 Victor A Ulibarri,1,2 Michael R Nadorff4,5 1Sleep & Human Health Institute, 2Maimonides Sleep Arts & Sciences, Ltd, Albuquerque, 3Los Alamos Medical Center, Los Alamos, NM, 4Department of Psychology, Mississippi State University, Mississippi, MS, 5Department of Psychiatry and Behavioral Sciences, Baylor College of Medicine, Houston, TX, USA Purpose: Emerging evidence shows that positive airway pressure (PAP treatment of obstructive sleep apnea (OSA and upper airway resistance syndrome (UARS in chronic insomnia patients (proposed “complex insomnia” disorder leads to substantial decreases in insomnia severity. Although continuous PAP (CPAP is the pressure mode most widely researched, intolerance to fixed pressurized air is rarely investigated or described in comorbidity patients. This retrospective study examined dual pressure, autoadjusting PAP modes in chronic, complex insomnia disorder patients.Patients and methods: Chronic insomnia disorder patients (mean [SD] insomnia severity index [ISI] =19.11 [3.34] objectively diagnosed with OSA or UARS and using either autobilevel PAP device or adaptive servoventilation (ASV device after failing CPAP therapy (frequently due to intolerance to pressurized air, poor outcomes, or emergence of CSA were divided into PAP users (≥20 h/wk and partial users (<20 h/wk for comparison. Subjective and objective baseline and follow-up measures were analyzed.Results: Of the 302 complex insomnia patients, PAP users (n=246 averaged 6.10 (1.78 nightly hours and 42.71 (12.48 weekly hours and partial users (n=56 averaged 1.67 (0.76 nightly hours and 11.70 (5.31 weekly hours. For mean (SD decreases in total ISI scores, a significant (group × time interaction was observed (F[1,300]=13.566; P<0.0001 with PAP users (–7.59 [5.92]; d=1.63 showing superior results to partial users (-4.34 [6.13]; d=0.81. Anecdotally, patients reported better tolerability with advanced PAP

  9. Nasal pillows as an alternative interface in patients with obstructive sleep apnoea syndrome initiating continuous positive airway pressure therapy.

    LENUS (Irish Health Repository)

    Ryan, Silke

    2012-02-01

    Side-effects directly due to the nasal mask are common in patients with obstructive sleep apnoea syndrome (OSAS) commencing continuous positive airway pressure (CPAP). Recently, nasal pillows have been designed to overcome these issues. Limited evidence exists of the benefits and effectiveness of these devices. Twenty-one patients (19 male, 49+\\/-10years) with the established diagnosis of OSAS [apnoea\\/hypopnoea index (AHI): 52+\\/-22] and who had a successful CPAP titration were commenced on CPAP therapy (10+\\/-2cmH2O), and randomized to 4weeks of a nasal pillow (P) and a standard nasal mask (M) in a crossover design. Outcome measures were objective compliance, AHI, quality of life, Epworth Sleepiness Score (ESS) and CPAP side-effects. There was no difference in compliance (M versus P: 5.1+\\/-1.9h versus 5.0+\\/-1.7h; P=0.701) and AHI (2.6+\\/-2.7 versus 3.0+\\/-2.9; P=0.509). Quality of life and ESS improved with CPAP, but there was no difference in the extent of improvement between both devices. Usage of nasal pillows resulted in less reported pressure on the face and more subjects found the nasal pillow the more comfortable device. However, there was no clear overall preference for either device at the end of the study (mask=57%, pillow=43%; P=0.513). The applied CPAP pressure did not correlate with compliance, AHI and ESS. Furthermore, no differences in outcome parameters were noted comparing groups with CPAP pressure <10 and >\\/=10cm H(2) O. Nasal pillows are equally effective in CPAP therapy, but do not generally lead to improved compliance.

  10. A real-world comparison of apnea-hypopnea indices of positive airway pressure device and polysomnography.

    Directory of Open Access Journals (Sweden)

    Ritwick Agrawal

    Full Text Available The apnea hypopnea index (AHI reported by positive airway pressure (PAP device is widely used in clinical practice, yet its correlation with standardized AHI obtained during the sleep study is not established. The current study was conducted to investigate the correlation between AHI estimated by the PAP device and reported on the smart card with the AHI found during the PAP polysomnography (PSG in the "real world" setting at an academic sleep center. We retrospectively reviewed the medical records of 280 patients who underwent a PAP titration PSG at Drexel sleep center, and were later prescribed a PAP device. The AHI was categorized in clinically relevant subgroups (as AHI ≤5 and AHI >5. The AHI at the final pressure on the PSG and the average AHI from the prescribed PAP device were compared. The results showed that in the majority (77.3% of patients (126 of 163, the AHI from both PAP device and PSG correlated well and were in the same category (AHI ≤5 and AHI >5 respectively. The majority of patients (80.7% with PSG AHI of 5, 61.5% patients reported good control, with AHI <5 on PAP device AHI. We conclude that in a majority of patients who were optimally titrated in the sleep laboratory, the PAP device continued to show optimal control at home.

  11. Nasal Continuous Positive Airway Pressure Inhibits Gastroesophageal Reflux in Newborn Lambs

    Science.gov (United States)

    Djeddi, Djamal; Cantin, Danny; Samson, Nathalie; Praud, Jean-Paul

    2014-01-01

    Background Using esophageal pHmetry, nasal CPAP (nCPAP) has been shown to decrease acid gastroesophageal reflux (GER) in adult humans. Although both GER (mainly non-acid) and nCPAP use are very frequent in newborns, the effect of nCPAP on GER in early life is unknown. Having recently shown that the newborn lamb is a unique model for studying neonatal GER, our main objective was to assess the effect of nCPAP on GER in newborn lambs. Methods Eight newborn lambs, aged 2–3 days, were studied. Continuous esophageal pH-Impedance monitoring and polysomnography were performed for six hours during both spontaneous breathing and nCPAP application at 6 cmH2O (nCPAP6), in a randomized order. Results were compared in the two experimental conditions, as well as without CPAP during the following 6 hours. Results i) nCPAP6 virtually abolished GER [mean ±SD reflux number for 6 h = 9.1±8.6 without nCPAP6 vs. 0.6±1 with nCPAP6, PCPAP are needed to confirm this result in human infants. PMID:25226514

  12. Upper airway resistance syndrome.

    Science.gov (United States)

    Montserrat, J M; Badia, J R

    1999-03-01

    This article reviews the clinical picture, diagnosis and management of the upper airway resistance syndrome (UARS). Presently, there is not enough data on key points like the frequency of UARS and the morbidity associated with this condition. Furthermore, the existence of LIARS as an independent sleep disorder and its relation with snoring and obstructive events is in debate. The diagnosis of UARS is still a controversial issue. The technical limitations of the classic approach to monitor airflow with thermistors and inductance plethysmography, as well as the lack of a precise definition of hypopnea, may have led to a misinterpretation of UARS as an independent diagnosis from the sleep apnea/hypopnea syndrome. The diagnosis of this syndrome can be missed using a conventional polysomnographic setting unless appropriate techniques are applied. The use of an esophageal balloon to monitor inspiratory effort is currently the gold standard. However, other sensitive methods such as the use of a pneumotachograph and, more recently, nasal cannula/pressure transducer systems or on-line monitoring of respiratory impedance with the forced oscillation technique may provide other interesting possibilities. Recognition and characterization of this subgroup of patients within sleep breathing disorders is important because they are symptomatic and may benefit from treatment. Management options to treat UARS comprise all those currently available for sleep apnea/hypopnea syndrome (SAHS). However, the subset of patients classically identified as LIARS that exhibit skeletal craneo-facial abnormalities might possibly obtain further benefit from maxillofacial surgery.

  13. Effects of continuous positive airway pressure on neurocognitive function in obstructive sleep apnea patients: The Apnea Positive Pressure Long-term Efficacy Study (APPLES).

    Science.gov (United States)

    Kushida, Clete A; Nichols, Deborah A; Holmes, Tyson H; Quan, Stuart F; Walsh, James K; Gottlieb, Daniel J; Simon, Richard D; Guilleminault, Christian; White, David P; Goodwin, James L; Schweitzer, Paula K; Leary, Eileen B; Hyde, Pamela R; Hirshkowitz, Max; Green, Sylvan; McEvoy, Linda K; Chan, Cynthia; Gevins, Alan; Kay, Gary G; Bloch, Daniel A; Crabtree, Tami; Dement, William C

    2012-12-01

    To determine the neurocognitive effects of continuous positive airway pressure (CPAP) therapy on patients with obstructive sleep apnea (OSA). The Apnea Positive Pressure Long-term Efficacy Study (APPLES) was a 6-month, randomized, double-blind, 2-arm, sham-controlled, multicenter trial conducted at 5 U.S. university, hospital, or private practices. Of 1,516 participants enrolled, 1,105 were randomized, and 1,098 participants diagnosed with OSA contributed to the analysis of the primary outcome measures. Active or sham CPAP MEASUREMENTS: THREE NEUROCOGNITIVE VARIABLES, EACH REPRESENTING A NEUROCOGNITIVE DOMAIN: Pathfinder Number Test-Total Time (attention and psychomotor function [A/P]), Buschke Selective Reminding Test-Sum Recall (learning and memory [L/M]), and Sustained Working Memory Test-Overall Mid-Day Score (executive and frontal-lobe function [E/F]) The primary neurocognitive analyses showed a difference between groups for only the E/F variable at the 2 month CPAP visit, but no difference at the 6 month CPAP visit or for the A/P or L/M variables at either the 2 or 6 month visits. When stratified by measures of OSA severity (AHI or oxygen saturation parameters), the primary E/F variable and one secondary E/F neurocognitive variable revealed transient differences between study arms for those with the most severe OSA. Participants in the active CPAP group had a significantly greater ability to remain awake whether measured subjectively by the Epworth Sleepiness Scale or objectively by the maintenance of wakefulness test. CPAP treatment improved both subjectively and objectively measured sleepiness, especially in individuals with severe OSA (AHI > 30). CPAP use resulted in mild, transient improvement in the most sensitive measures of executive and frontal-lobe function for those with severe disease, which suggests the existence of a complex OSA-neurocognitive relationship. Registered at clinicaltrials.gov. Identifier: NCT00051363. Kushida CA; Nichols DA; Holmes

  14. Supplemental Carbon Dioxide Stabilizes the Upper Airway in Volunteers Anesthetized with Propofol.

    Science.gov (United States)

    Ruscic, Katarina Jennifer; Bøgh Stokholm, Janne; Patlak, Johann; Deng, Hao; Simons, Jeroen Cedric Peter; Houle, Timothy; Peters, Jürgen; Eikermann, Matthias

    2018-05-10

    Propofol impairs upper airway dilator muscle tone and increases upper airway collapsibility. Preclinical studies show that carbon dioxide decreases propofol-mediated respiratory depression. We studied whether elevation of end-tidal carbon dioxide (PETCO2) via carbon dioxide insufflation reverses the airway collapsibility (primary hypothesis) and impaired genioglossus muscle electromyogram that accompany propofol anesthesia. We present a prespecified, secondary analysis of previously published experiments in 12 volunteers breathing via a high-flow respiratory circuit used to control upper airway pressure under propofol anesthesia at two levels, with the deep level titrated to suppression of motor response. Ventilation, mask pressure, negative pharyngeal pressure, upper airway closing pressure, genioglossus electromyogram, bispectral index, and change in end-expiratory lung volume were measured as a function of elevation of PETCO2 above baseline and depth of propofol anesthesia. PETCO2 augmentation dose-dependently lowered upper airway closing pressure with a decrease of 3.1 cm H2O (95% CI, 2.2 to 3.9; P < 0.001) under deep anesthesia, indicating improved upper airway stability. In parallel, the phasic genioglossus electromyogram increased by 28% (23 to 34; P < 0.001). We found that genioglossus electromyogram activity was a significant modifier of the effect of PETCO2 elevation on closing pressure (P = 0.005 for interaction term). Upper airway collapsibility induced by propofol anesthesia can be reversed in a dose-dependent manner by insufflation of supplemental carbon dioxide. This effect is at least partly mediated by increased genioglossus muscle activity.

  15. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... today. ANNUAL FUND Become a Corporate Supporter Cause Marketing Make a Charitable Gift Our Corporate Supporters Workplace ... for airway clearance. Facebook Twitter Email More Related Content Medications Autogenic Drainage Positive Expiratory Pressure High-Frequency ...

  16. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Clinician Career Development Awards Clinician Training Awards Mutation Analysis Program Network News Network News: March 2018 Network ... for airway clearance. Facebook Twitter Email More Related Content Medications Autogenic Drainage Positive Expiratory Pressure High-Frequency ...

  17. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Clinician Career Development Awards Clinician Training Awards Mutation Analysis Program Network News Network News: June 2018 Network ... for airway clearance. Facebook Twitter Email More Related Content Medications Autogenic Drainage Positive Expiratory Pressure High-Frequency ...

  18. Airway Clearance Techniques (ACTs)

    Science.gov (United States)

    ... infant or child manage their lung health, watch parents of children with CF and a respiratory therapist talk about the different techniques they use for airway ... Positive Expiratory Pressure High-Frequency Chest Wall Oscillation (the Vest) Follow ...

  19. Utility of formulas predicting the optimal nasal continuous positive airway pressure in a Greek population.

    Science.gov (United States)

    Schiza, Sophia E; Bouloukaki, Izolde; Mermigkis, Charalampos; Panagou, Panagiotis; Tzanakis, Nikolaos; Moniaki, Violeta; Tzortzaki, Eleni; Siafakas, Nikolaos M

    2011-09-01

    There have been reports that optimal CPAP pressure can be predicted from a previously derived formula, with the Hoffstein formula being the most accurate and accepted in the literature so far. However, the validation of this predictive model has not been applied in different clinical settings. Our aim was to compare both the Hoffstein prediction formula and a newly derived formula to the CPAP pressure setting assessed during a formal CPAP titration study. We prospectively studied 1,111 patients (871 males/240 females) with obstructive sleep apnea hypopnea syndrome (OSAHS) undergoing a CPAP titration procedure. In this large population sample, we tested the Hoffstein formula, utilizing body mass index (BMI), neck circumference and apnea/hypopnea index (AHI), and we compared it with our new formula that included not only AHI and BMI but also smoking history and gender adjustment. We found that using the Hoffstein prediction formula, successful prediction (predicted CPAP pressure within ±2 cm H(2)O compared to the finally assessed optimum CPAP pressure during titration) was accomplished in 873 patients (79%), with significant correlation between CPAP predicted pressure (CPAPpred(1)) and the optimum CPAP pressure (CPAPopt) [r = 0.364, p history and gender adjustment, successful prediction was accomplished in 1,057 patients (95%), with significant correlation between CPAP predicted pressure (CPAPpred(2)) and the CPAPopt (r = 0.392, p titration. It may also be possible to shorten CPAP titration and perhaps in selected cases to combine it with the initial diagnostic study.

  20. Interaction between peri-operative blood transfusion, tidal volume, airway pressure and postoperative ARDS: an individual patient data meta-analysis.

    Science.gov (United States)

    Serpa Neto, Ary; Juffermans, Nicole P; Hemmes, Sabrine N T; Barbas, Carmen S V; Beiderlinden, Martin; Biehl, Michelle; Fernandez-Bustamante, Ana; Futier, Emmanuel; Gajic, Ognjen; Jaber, Samir; Kozian, Alf; Licker, Marc; Lin, Wen-Qian; Memtsoudis, Stavros G; Miranda, Dinis Reis; Moine, Pierre; Paparella, Domenico; Ranieri, Marco; Scavonetto, Federica; Schilling, Thomas; Selmo, Gabriele; Severgnini, Paolo; Sprung, Juraj; Sundar, Sugantha; Talmor, Daniel; Treschan, Tanja; Unzueta, Carmen; Weingarten, Toby N; Wolthuis, Esther K; Wrigge, Hermann; de Abreu, Marcelo Gama; Pelosi, Paolo; Schultz, Marcus J

    2018-01-01

    Transfusion of blood products and mechanical ventilation with injurious settings are considered risk factors for postoperative lung injury in surgical Patients. A systematic review and individual patient data meta-analysis was done to determine the independent effects of peri-operative transfusion of blood products, intra-operative tidal volume and airway pressure in adult patients undergoing mechanical ventilation for general surgery, as well as their interactions on the occurrence of postoperative acute respiratory distress syndrome (ARDS). Observational studies and randomized trials were identified by a systematic search of MEDLINE, CINAHL, Web of Science, and CENTRAL and screened for inclusion into a meta-analysis. Individual patient data were obtained from the corresponding authors. Patients were stratified according to whether they received transfusion in the peri-operative period [red blood cell concentrates (RBC) and/or fresh frozen plasma (FFP)], tidal volume size [≤7 mL/kg predicted body weight (PBW), 7-10 and >10 mL/kg PBW] and airway pressure level used during surgery (≤15, 15-20 and >20 cmH 2 O). The primary outcome was development of postoperative ARDS. Seventeen investigations were included (3,659 patients). Postoperative ARDS occurred in 40 (7.2%) patients who received at least one blood product compared to 40 patients (2.5%) who did not [adjusted hazard ratio (HR), 2.32; 95% confidence interval (CI), 1.25-4.33; P=0.008]. Incidence of postoperative ARDS was highest in patients ventilated with tidal volumes of >10 mL/kg PBW and having airway pressures of >20 cmH 2 O receiving both RBC and FFP, and lowest in patients ventilated with tidal volume of ≤7 mL/kg PBW and having airway pressures of ≤15 cmH 2 O with no transfusion. There was a significant interaction between transfusion and airway pressure level (P=0.002) on the risk of postoperative ARDS. Peri-operative transfusion of blood products is associated with an increased risk of

  1. Nasal continuous positive airway pressure inhibits gastroesophageal reflux in newborn lambs.

    Directory of Open Access Journals (Sweden)

    Djamal Djeddi

    Full Text Available BACKGROUND: Using esophageal pHmetry, nasal CPAP (nCPAP has been shown to decrease acid gastroesophageal reflux (GER in adult humans. Although both GER (mainly non-acid and nCPAP use are very frequent in newborns, the effect of nCPAP on GER in early life is unknown. Having recently shown that the newborn lamb is a unique model for studying neonatal GER, our main objective was to assess the effect of nCPAP on GER in newborn lambs. METHODS: Eight newborn lambs, aged 2-3 days, were studied. Continuous esophageal pH-Impedance monitoring and polysomnography were performed for six hours during both spontaneous breathing and nCPAP application at 6 cmH2O (nCPAP(6, in a randomized order. Results were compared in the two experimental conditions, as well as without CPAP during the following 6 hours. RESULTS: i nCPAP(6 virtually abolished GER [mean ± SD reflux number for 6 h = 9.1 ± 8.6 without nCPAP(6 vs. 0.6 ± 1 with nCPAP(6, P<0.05]; ii GER number was also reduced during the 6 h-period following nCPAP(6 application (18 ± 16 without nCPAP(6 vs. 7 ± 8.1 with nCPAP(6, P<0.05; iii nCPAP(6 decreased the depth and duration of lower esophageal sphincter relaxation. CONCLUSIONS: nCPAP inhibits GER in the newborn lamb. Further clinical studies using different levels of nasal CPAP are needed to confirm this result in human infants.

  2. Sleep Apnea Related Risk of Motor Vehicle Accidents is Reduced by Continuous Positive Airway Pressure: Swedish Traffic Accident Registry Data

    Science.gov (United States)

    Karimi, Mahssa; Hedner, Jan; Häbel, Henrike; Nerman, Olle; Grote, Ludger

    2015-01-01

    Study Objectives: Obstructive sleep apnea (OSA) is associated with an increased risk of motor vehicle accidents (MVAs). The rate of MVAs in patients suspected of having OSA was determined and the effect of continuous positive airway pressure (CPAP) was investigated. Design: MVA rate in patients referred for OSA was compared to the rate in the general population using data from the Swedish Traffic Accident Registry (STRADA), stratified for age and calendar year. The risk factors for MVAs, using demographic and polygraphy data, and MVA rate before and after CPAP were evaluated in the patient group. Setting: Clinical sleep laboratory and population based control (n = 635,786). Patients: There were 1,478 patients, male sex 70.4%, mean age 53.6 (12.8) y. Interventions: CPAP. Measurements and Results: The number of accidents (n = 74) among patients was compared with the expected number (n = 30) from a control population (STRADA). An increased MVA risk ratio of 2.45 was found among patients compared with controls (P accident risk was most prominent in the elderly patients (65–80 y, seven versus two MVAs). In patients, driving distance (km/y), EDS (Epworth Sleepiness score ≥ 16), short habitual sleep time (≤ 5 h/night), and use of hypnotics were associated with increased MVA risk (odds ratios 1.2, 2.1, 2.7 and 2.1, all P ≤ 0.03). CPAP use ≥ 4 h/night was associated with a reduction of MVA incidence (7.6 to 2.5 accidents/1,000 drivers/y). Conclusions: The motor vehicle accident risk in this large cohort of unselected patients with obstructive sleep apnea suggests a need for accurate tools to identify individuals at risk. Sleep apnea severity (e.g., apnea-hypopnea index) failed to identify patients at risk. Citation: Karimi M, Hedner J, Häbel H, Nerman O, Grote L. Sleep apnea related risk of motor vehicle accidents is reduced by continuous positive airway pressure: Swedish traffic accident registry data. SLEEP 2015;38(3):341–349. PMID:25325460

  3. Development and evaluation of a self-efficacy instrument for Japanese sleep apnea patients receiving continuous positive airway pressure treatment

    Directory of Open Access Journals (Sweden)

    Saito A

    2015-01-01

    Full Text Available Ayako Saito,1 Shigeko Kojima,2 Fumihiko Sasaki,3 Masamichi Hayashi,4 Yuki Mieno,4 Hiroki Sakakibara,5 Shuji Hashimoto1 1Department of Hygiene, School of Medicine, Fujita Health University, Toyoake, Japan; 2Department of Rehabilitation, Faculty of Health Sciences, Nihon Fukushi University, Handa, Japan; 3SDB Research Laboratory, Takaoka Clinic, Nagoya, Japan; 4Department of Internal Medicine, Division of Respiratory Medicine and Clinical Allergy, Fujita Health University, Toyoake, Japan; 5Tokushige Kokyuki Clinic, Nagoya, Japan Abstract: The purpose of this study was to develop and evaluate a self-efficacy instrument for Japanese obstructive sleep apnea (OSA patients treated with continuous positive airway pressure (CPAP. Analyzed subjects were 653 Japanese OSA patients (619 males and 34 females treated with CPAP at a sleep laboratory in a respiratory clinic in a Japanese city. Based on Bandura's social cognitive theory, the CPAP Self-Efficacy Questionnaire for Sleep Apnea in Japanese (CSESA-J was developed by a focus group of experts, using a group interview of OSA patients for the items of two previous self-efficacy scales for Western sleep apnea patients receiving CPAP treatment. CSESA-J has two subscales, one for self-efficacy and the other for outcome expectancy, and consists of a total of 15 items. Content validity was confirmed by the focus group. Confirmatory factor analysis showed that the factor loadings of self-efficacy and outcome expectancy were 0.47–0.76 and 0.41–0.92, respectively, for the corresponding items. CSESA-J had a significant but weak positive association with the General Self-Efficacy Scale, and a strong positive association with “Self-efficacy scale on health behavior in patients with chronic disease.” Cronbach’s alpha coefficient was 0.85 for the self-efficacy subscale and 0.89 for the outcome expectancy subscale. The intraclass correlation coefficient using data from the first and second measurements with

  4. A randomised controlled trial on the effect of mask choice on residual respiratory events with continuous positive airway pressure treatment.

    Science.gov (United States)

    Ebben, Matthew R; Narizhnaya, Mariya; Segal, Alan Z; Barone, Daniel; Krieger, Ana C

    2014-06-01

    It has been found that mask style can affect the amount of continuous positive airway pressure (CPAP) required to reduce an apnoea/hyponoea index (AHI) to mask style to another post titration could affect the residual AHI with CPAP. The purpose of this study was to investigate the differences in residual AHI with CPAP treatment between oronasal and nasal masks. Twenty-one subjects (age mean (M)=62.9, body mass index (BMI) M=29.6 kg/m2) were randomised (14 subjects completed the protocol) to undergo an in-laboratory CPAP titration with either a nasal mask or an oronasal mask. Subjects were then assigned this mask for 3weeks of at-home CPAP use with the optimal treatment pressure determined on the laboratory study (CPAP M=8.4 cm of H2O). At the end of this 3-week period, data were collected from the CPAP machine and the subject was given the other mask to use with the same CPAP settings for the next 3weeks at home (if the nasal mask was given initially, the oronasal one was given later and vice versa). On completion of the second 3-week period, data on residual AHI were again collected and compared with the first 3-week period on CPAP. A Wilcoxon Signed-Rank Test (two-tailed) revealed that residual AHI with CPAP treatment was significantly higher with the oronasal compared with the nasal mask (z = -3.296, pmask, and 50% of the subjects had a residual AHI >10/h in the oronasal mask condition, even though all of these subjects were titrated to an AHI of mask compared with a nasal mask. Switching to an oronasal mask post titration results in an increase in residual AHI with CPAP treatment, and pressure adjustment may be warranted. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. [Influence of nasal continuous positive airway pressure on response to exercise in patients with obstructive sleep apnea syndrome].

    Science.gov (United States)

    Przybyłowski, Tadeusz; Bielicki, Piotr; Kumor, Marta; Hildebrand, Katarzyna; Maskey-Warzechowska, Marta; Wiwała, Joanna; Kościuch, Justyna; Korczyński, Piotr; Chazan, Ryszarda

    2006-01-01

    Obstructive sleep apnea syndrome (OSAS) patients are at risk of cardiovascular complications. The aim of this study was to assess the effect of treatment with continuous positive airway pressure (CPAP) on the response to symptom limited exercise test. twenty nine OSAS patients (1 F, 28 M), mean age 50.7+/-9.7 yrs with body mass index of 32.6+/-4.5 kg/m2 participated in the study. OSAS was diagnosed by overnight polysomnography. Incremental cardiopulmonary exercise test (CPET) on a treadmill was performed twice: before and after 2-3 weeks of regular treatment with CPAP. mean apnea + hypopnea index (AHI) before therapy was 57.6+/-12 h(-1). CPAP treatment did not change peak oxygen consumption (VO2max) (38.3+/-9.0 vs. 38.9+/-6.9 mlO2/kg/min, p=ns) or peak heart rate (153.4+/-21 min- vs. 155.5+/-22 min(-1), p=ns). There were no significant changes in ventilation or gas exchange variables. However, a decrease in peak systolic blood pressure from 194.5+/-24 mmHg to 186.7+/-27.9 mmHg (prate (at 1st minute and minutes 3 - 6) and mean arterial pressure (MAP) (minutes 4-7) with CPAP treatment was observed. Significant correlations between VO2max and AHI (r=-0,38, p<0,05); MAP at peak exercise and: AHI, mean oxygen saturation (SaO2) during sleep, minutes of sleep with SaO2<90% (T90); MAP at recovery (minutes 3-8) and T90 before CPAP treatment were also noted. OSAS patients are not limited on exercise. Treatment with nasal CPAP attenuates circulatory response to incremental exercise on a treadmill.

  6. Comparison of intermittent positive pressure breathing and temporary positive expiratory pressure in patients with severe chronic obstructive pulmonary disease.

    Science.gov (United States)

    Nicolini, Antonello; Mollar, Elena; Grecchi, Bruna; Landucci, Norma

    2014-01-01

    Results supporting the use and the effectiveness of positive expiratory, pressure devices in chronic obstructive pulmonary disease (COPD) patients are still controversial, We have tested the hypothesis that adding TPEP or IPPB to standard pharmacological therapy may provide additional clinical benefit over, pharmacological therapy only in patients with severe COPD. Fourty-five patients were randomized in three groups: a group was treated; with IPPB,a group was treated with TPEP and a group with pharmacological; therapy alone (control group). Primary outcome measures included the measurement of scale or, questionnaire concerning dyspnea (MRC scale),dyspnea,cough, and, sputum (BCSS) and quality of life (COPD assessment test) (CAT). Secondary, outcome measures were respiratory function testing,arterial blood gas,analysis,and hematological examinations. Both patients in the IPPB group and in the TPEP group showed a significant, improvement in two of three tests (MRC,CAT) compared to the control, group.However,in the group comparison analysis for, the same variables between IPPB group and TPEP group we observed a, significant improvement in the IPPB group (P≤.05 for MRC and P≤.01 for, CAT). The difference of action of the two techniques are evident in the results of, pulmonary function testing: IPPB increases FVC, FEV1, and MIP; this reflects, its capacity to increase lung volume. Also TPEP increases FVC and FEV1 (less, than IPPB), but increases MEP, while decreasing total lung capacity and, residual volume. The two techniques (IPPB and TPEP) improves significantly dyspnea; quality of; life tools and lung function in patients with severe COPD. IPPB demonstrated a greater effectiveness to improve dyspnea and quality of life tools (MRC, CAT) than TPEP. Copyright © 2013 SEPAR. Published by Elsevier Espana. All rights reserved.

  7. Cystic fibrosis airway secretions exhibit mucin hyperconcentration and increased osmotic pressure

    Science.gov (United States)

    Henderson, Ashley G.; Ehre, Camille; Button, Brian; Abdullah, Lubna H.; Cai, Li-Heng; Leigh, Margaret W.; DeMaria, Genevieve C.; Matsui, Hiro; Donaldson, Scott H.; Davis, C. William; Sheehan, John K.; Boucher, Richard C.; Kesimer, Mehmet

    2014-01-01

    The pathogenesis of mucoinfective lung disease in cystic fibrosis (CF) patients likely involves poor mucus clearance. A recent model of mucus clearance predicts that mucus flow depends on the relative mucin concentration of the mucus layer compared with that of the periciliary layer; however, mucin concentrations have been difficult to measure in CF secretions. Here, we have shown that the concentration of mucin in CF sputum is low when measured by immunologically based techniques, and mass spectrometric analyses of CF mucins revealed mucin cleavage at antibody recognition sites. Using physical size exclusion chromatography/differential refractometry (SEC/dRI) techniques, we determined that mucin concentrations in CF secretions were higher than those in normal secretions. Measurements of partial osmotic pressures revealed that the partial osmotic pressure of CF sputum and the retained mucus in excised CF lungs were substantially greater than the partial osmotic pressure of normal secretions. Our data reveal that mucin concentration cannot be accurately measured immunologically in proteolytically active CF secretions; mucins are hyperconcentrated in CF secretions; and CF secretion osmotic pressures predict mucus layer–dependent osmotic compression of the periciliary liquid layer in CF lungs. Consequently, mucin hypersecretion likely produces mucus stasis, which contributes to key infectious and inflammatory components of CF lung disease. PMID:24892808

  8. Positive airway pressure adherence and mask interface in the setting of sinonasal symptoms.

    Science.gov (United States)

    Schell, Amy E; Soose, Ryan J

    2017-10-01

    Despite reports of lower positive pressure adherence rates with oronasal masks, patients with sinonasal problems are often prescribed this interface over a nasal interface. The aim of this study was to characterize the relationship between mask type and therapy adherence in the setting of sinonasal symptoms. Retrospective case series with chart review. We reviewed 328 patients who underwent positive pressure titration between January 2012 and May 2015. Follow-up adherence data were available for 218 patients (66.5%). Multivariate analysis examined whether patients with sinonasal symptoms have improved adherence with oronasal masks compared to nasal or nasal pillow interfaces. At a median follow-up of 95 days, positive pressure adherence in patients with sinonasal symptoms was highest with the nasal pillow interface. When compared with oronasal interfaces, the odds of adequate therapy adherence were >5 times greater with nasal pillow interfaces (odds ratio [OR] = 5.20, 95% confidence interval [CI] = 1.61-16.80, P = .006) and >3 times greater with nasal interfaces (OR = 3.67, 95% CI = 1.20-11.26, P = .02) in these symptomatic patients. The presence of nasal problems does not predict the need for an oronasal mask. Positive pressure adherence rates are higher with nasal and nasal pillow interfaces compared to oronasal masks, even in patients with sinonasal complaints. 4. Laryngoscope, 127:2418-2422, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  9. Effects of positive airway pressure therapy on cardiovascular and metabolic markers in males with obstructive sleep apnea.

    Science.gov (United States)

    Feliciano, A; Oliveira, M J; Cysneiros, A; Martinho, C; Reis, R P; Penque, D; Pinto, P; Bárbara, C

    Obstructive sleep apnea syndrome (OSAS) is associated with cardiovascular/metabolic complications. Some analytical parameters (homocysteine, glycemic and lipidic profiles) are recognized markers of these consequences. Limited data is available on the association of these markers and OSAS's severity/response to positive airway pressure therapy (PAP). In this prospective study we analyzed polysomnographic and analytical data of male patients admitted to sleep laboratory. The aim was to evaluate metabolic/cardiovascular markers in snorers and OSAS patients, to relate with sleep parameters and PAP response. One-hundred and three patients were included, and 73 (71%) were OSAS patients. OSAS patients were similar to snorers except for higher body mass index (BMI) and dyslipidemia. Severe OSAS patients showed higher glycemia, HbA1c, insulin, and insulin resistance, and lower HDL cholesterol in comparison to mild-moderate (pprofile and triglycerides were slightly correlated with OSAS severity. 46 OSAS patients were submitted to 6 months of PAP, with a statistical decrease in mean values of homocysteine, glycemia, total and LDL cholesterol (pprofiles changed significantly after 6 months of PAP therapy in OSAS, supporting its cardiovascular and metabolic protective effect. Our study has reinforced the importance of analytical cardiovascular/metabolic evaluation as complementary tool of diagnosis/treatment response in OSAS. Copyright © 2017 Sociedade Portuguesa de Pneumologia. Published by Elsevier España, S.L.U. All rights reserved.

  10. Estimates of cost-effectiveness of prehospital continuous positive airway pressure in the management of acute pulmonary edema.

    Science.gov (United States)

    Hubble, Michael W; Richards, Michael E; Wilfong, Denise A

    2008-01-01

    To estimate the cost-effectiveness of continuous positive airway pressure (CPAP) in managing prehospital acute pulmonary edema in an urban EMS system. Using estimates from published reports on prehospital and emergency department CPAP, a cost-effectiveness model of implementing CPAP in a typical urban EMS system was derived from the societal perspective as well as the perspective of the implementing EMS system. To assess the robustness of the model, a series of univariate and multivariate sensitivity analyses was performed on the input variables. The cost of consumables, equipment, and training yielded a total cost of $89 per CPAP application. The theoretical system would be expected to use CPAP 4 times per 1000 EMS patients and is expected to save 0.75 additional lives per 1000 EMS patients at a cost of $490 per life saved. CPAP is also expected to result in approximately one less intubation per 6 CPAP applications and reduce hospitalization costs by $4075 per year for each CPAP application. Through sensitivity analyses the model was verified to be robust across a wide range of input variable assumptions. Previous studies have demonstrated the clinical effectiveness of CPAP in the management of acute pulmonary edema. Through a theoretical analysis which modeled the costs and clinical benefits of implementing CPAP in an urban EMS system, prehospital CPAP appears to be a cost-effective treatment.

  11. Effects of 12 months continuous positive airway pressure on sympathetic activity related brainstem function and structure in obstructive sleep apnea.

    Directory of Open Access Journals (Sweden)

    Luke Anthony Henderson

    2016-03-01

    Full Text Available Muscle sympathetic nerve activity (MSNA is greatly elevated in patients with obstructive sleep apnoea (OSA during normoxic daytime wakefulness. Increased MSNA is a precursor to hypertension and elevated cardiovascular morbidity and mortality. However, the mechanisms underlying the high MSNA in OSA are not well understood. In this study we used concurrent microneurography and magnetic resonance imaging to explore MSNA-related brainstem activity changes and anatomical changes in 15 control and 15 subjects with OSA prior to and following 6 and 12 months of continuous positive airway pressure (CPAP treatment. We found that 6 and 12 months of CPAP treatment significantly reduced the elevated resting MSNA in individuals with OSA. Furthermore, this MSNA reduction was associated with restoration of MSNA-related activity and structural changes in the medullary raphe, rostral ventrolateral medulla, dorsolateral pons and ventral midbrain. This restoration occurred after 6 months of CPAP treatment and was maintained following 12 months CPAP. These findings show that continual CPAP treatment is an effective long-term treatment for elevated MNSA likely due to its effects on restoring brainstem structure and function.

  12. Influence of continuous positive airway pressure on outcomes of rehabilitation in stroke patients with obstructive sleep apnea.

    Science.gov (United States)

    Ryan, Clodagh M; Bayley, Mark; Green, Robin; Murray, Brian J; Bradley, T Douglas

    2011-04-01

    In stroke patients, obstructive sleep apnea (OSA) is associated with poorer functional outcomes than in those without OSA. We hypothesized that treatment of OSA by continuous positive airway pressure (CPAP) in stroke patients would enhance motor, functional, and neurocognitive recovery. This was a randomized, open label, parallel group trial with blind assessment of outcomes performed in stroke patients with OSA in a stroke rehabilitation unit. Patients were assigned to standard rehabilitation alone (control group) or to CPAP (CPAP group). The primary outcomes were the Canadian Neurological scale, the 6-minute walk test distance, sustained attention response test, and the digit or spatial span-backward. Secondary outcomes included Epworth Sleepiness scale, Stanford Sleepiness scale, Functional Independence measure, Chedoke McMaster Stroke assessment, neurocognitive function, and Beck depression inventory. Tests were performed at baseline and 1 month later. Patients assigned to CPAP (n=22) experienced no adverse events. Regarding primary outcomes, compared to the control group (n=22), the CPAP group experienced improvement in stroke-related impairment (Canadian Neurological scale score, PStroke assessment of upper and lower limb motor recovery test of the leg (P=0.001), and the affective component of depression (P=0.006), but not neurocognitive function. Treatment of OSA by CPAP in stroke patients undergoing rehabilitation improved functional and motor, but not neurocognitive outcomes. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00221065.

  13. [Intraabdominal fat redistribution in long-term continuous positive airway pressure treatment in obstructive sleep apnea patients].

    Science.gov (United States)

    Català, Raquel; Ferré, Raimón; Sangenís, Sandra; Cabré, Anna; Hernández-Flix, Salvador; Masana, Lluís

    2016-06-03

    Obesity is the main risk factor for obstructive sleep apnoea (OSA). The aim was to evaluate the long-term effect of continuous positive airway pressure (CPAP) on intraabdominal fat distribution in OSA patients. Fifty OSA patients with and 35 without CPAP treatment criteria were followed-up for 2 years. Visceral and subcutaneous adipose tissue (VAT and SAT) and preaortic intraabdominal fat (PIF) were assessed by sonography. In the non CPAP treated group, SAT and VAT mean values didn't change, while a significantly PIF growth was observed (55.19 [23.44] vs. 63.45 [23.94] mm, P=.021). In the CPAP treated group, VAT and PIF mean were not changed, while SAT decreased significantly (11.29 [5.69] vs. 10.47 [5.71] mm, P=.012). Long-term CPAP treatment produces intraabdominal fat redistribution and is associated with an anthropometric profile of lower cardiovascular risk in OSA patients. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.

  14. Effect of Continuous Positive Airway Pressure on Adiponectin in Patients with Obstructive Sleep Apnea: A Meta-Analysis.

    Directory of Open Access Journals (Sweden)

    Li-Da Chen

    Full Text Available Obstructive sleep apnea (OSA has been suggested to be associated with low levels of adiponectin. Continuous positive airway pressure (CPAP is the gold standard treatment for OSA; however, previous studies assessing the effect of CPAP on adiponectin in patients with OSA yielded conflicting results. The present meta-analysis was performed to determine whether CPAP therapy could increase adiponectin levels.Two reviewers independently searched PubMed, Cochrane library, Embase and Web of Science before February 2015. Information on characteristics of subjects, study design and pre- and post-CPAP treatment of serum adiponectin was extracted for analysis. Standardized mean difference (SMD was used to analyze the summary estimates for CPAP therapy.Eleven studies involving 240 patients were included in this meta-analysis, including ten observational studies and one randomized controlled study. The meta-analysis showed that there was no change of adiponectin levels before and after CPAP treatment in OSA patients (SMD = 0.059, 95% confidence interval (CI = -0.250 to 0.368, z = 0.37, p = 0.710. Subgroup analyses indicated that the results were not affected by age, baseline body mass index, severity of OSA, CPAP therapy duration, sample size and racial differences.This meta-analysis suggested that CPAP therapy has no impact on adiponectin in OSA patients, without significant changes in body weight. Further large-scale, well-designed long-term interventional investigations are needed to clarify this issue.

  15. Oxidative stress mediated arterial dysfunction in patients with obstructive sleep apnoea and the effect of continuous positive airway pressure treatment

    Directory of Open Access Journals (Sweden)

    Del Ben Maria

    2012-07-01

    Full Text Available Abstract Background Several studies suggest an increase of oxidative stress and a reduction of endothelial function in obstructive sleep apnoea syndrome (OSAS. We assessed the association between OSAS, endothelial dysfunction and oxidative stress. Further aim was to evaluate the effect of nasal continuous positive airway pressure (nCPAP on oxidative stress and arterial dysfunction. Methods We studied 138 consecutive patients with heavy snoring and possible OSAS. Patients underwent unattended overnight home polysomnography. Ten patients with severe OSAS were revaluated after 6 months of nCPAP therapy. To assess oxidative stress in vivo, we measured urinary 8-iso-PGF2α and serum levels of soluble NOX2-derived peptide (sNOX2-dp. Serum levels of nitrite/nitrate (NOx were also determined. Flow-mediated brachial artery dilation (FMD was measured to asses endothelial function. Results Patients with severe OSAS had higher urinary 8-iso-PGF2α (p Conclusions The results of our study indicate that patients with OSAS and cardiometabolic comorbidities have increased oxidative stress and arterial dysfunction that are partially reversed by nCPAP treatment.

  16. Self-Reported Napping Behavior Change After Continuous Positive Airway Pressure Treatment in Older Adults with Obstructive Sleep Apnea.

    Science.gov (United States)

    Hsieh, Cheng-Fang; Riha, Renata L; Morrison, Ian; Hsu, Chung-Yao

    2016-08-01

    To assess the effect of continuous positive airway pressure (CPAP) on napping behavior in adults aged 60 and older with obstructive sleep apnea-hypopnea syndrome (OSAHS). Retrospective cohort study using questionnaires. Sleep center. Individuals starting CPAP treatment between April 2010 and March 2012 (mean age 65.2 ± 4.7; M:F = 3.9:1; N = 107). All subjects underwent sleep studies, clinical reviews, and CPAP adherence checks and completed a questionnaire regarding CPAP adherence, current employment status, sleep patterns before and after CPAP, and factors affecting their current sleep patterns. CPAP treatment duration was 82.7 ± 30.0 weeks, and objective adherence was 5.4 ± 2.0 hours per night overall. Daytime nap frequency before CPAP treatment was higher in those with a history of stroke or cardiovascular disease. Both sexes had a significant reduction in daytime napping (men, P napping (men, P nap duration (men, P nap duration was associated with younger age (odds ratio (OR) = 0.86, P = .04), a decrease in ESS score (OR = 1.20, P = .03), and longer self-reported daily nap duration at baseline (OR = 31.52, P nap frequency and daily nap duration. Aging or shorter baseline daily nap duration may attenuate this effect. © 2016, Copyright the Authors Journal compilation © 2016, The American Geriatrics Society.

  17. Effects of continuous positive airway pressure on hemorheology and serum inflammatory factors in patients with obstructive sleep apnea hypopnea syndrome

    Directory of Open Access Journals (Sweden)

    Ye-Jun Liu

    2016-02-01

    Full Text Available Objective: To investigate the effects of continuous positive airway pressure (CPAP on hemorheology and serum inflammatory factors in patients with obstructive sleep apnea hypopnea syndrome (OSAHS. Methods: A total of 87 patients with moderate and severe OSAHS from Department of Otolaryngology-Head and Neck Surgery of South Central Hospital of Wuhan University and Qianjiang Central Hospital were selected as research objects in the treatment group, while 37 healthy individuals were chosen as objects in the control group. The changes of hemorheology indexes including hematocrit (HCT, whole blood viscosity, platelet aggregation (PAG and endothelin (ET as well as serum inflammatory factors including interleukin-6 (IL-6, IL-18 and tumor necrosis factor-α (TNF-α were measured in the control group and the treatment group, and comparisons involving these indexes were made between the two groups. Results: Before treatment, the hemorheology indexes HCT, whole blood viscosity (high, medium and low sheer rates, PAG and ET as well as the inflammatory factors IL-6, IL-18 and TNF-α levels were significantly higher than those in the control group; after CPAP treatment, all these indexed mentioned above in the treatment group were significantly decreased compared with before treatment. Conclusion: CPAP treatment has a reliable therapeutic effect on OSAHS patients, which can obviously improve the hemorheology and largely reduce the inflammatory response.

  18. Continuous Positive Airway Pressure versus Mechanical Ventilation on the Fist Day of Life in Very Low-Birth-Weight Infants

    Science.gov (United States)

    Flannery, Dustin D.; O’Donnell, Elizabeth; Kornhauser, Mike; Dysart, Kevin; Greenspan, Jay; Aghai, Zubair H.

    2017-01-01

    Objective The objective of this study was to determine differences in the incidence of bronchopulmonary dysplasia (BPD) or death in very low-birth-weight (VLBW) infants managed successfully on continuous positive airway pressure (CPAP) versus mechanical ventilation on the first day of life (DOL). Study Design This is a retrospective analysis of the Alere neonatal database for infants born between January 2009 and December 2014, weighing ≤ 1,500 g. Baseline demographics, clinical characteristics, and outcomes were compared between the two groups. Multivariate regression analysis was performed to control the variables that differ in bivariate analysis. Results In this study, 4,629 infants (birth weight 1,034 ± 290 g, gestational age 28.1 ± 2.5 weeks) met the inclusion criteria. The successful use of early CPAP was associated with a significant reduction in BPD or death (p CPAP on the first DOL in VLBW infants is associated with a reduced risk of BPD or death. PMID:27057767

  19. [The clinical effect of airway pressure release ventilation for acute lung injury/acute respiratory distress syndrome].

    Science.gov (United States)

    Song, Shaohua; Tian, Huiyu; Yang, Xiufen; Hu, Zhenjie

    2016-01-01

    To evaluate the effect of airway pressure release ventilation (APRV) in patients with acute lung injury/acute respiratory distress syndrome (ALI/ARDS), to evaluate the extent of ventilator-induced lung injury (VILI), and to explore its possible mechanism. A prospective study was conducted in the Department of Critical Care Medicine of the First Hospital of Hebei Medical University from December 2010 to February 2012. The patients with ALI/ARDS were enrolled. They were randomly divided into two groups. The patients in APRV group were given APRV pattern, while those in control group were given lung protection ventilation, synchronized intermittent mandatory ventilation with positive end-expiratory pressure (SIMV+PEEP). All patients were treated with AVEA ventilator. The parameters such as airway peak pressure (Ppeak), mean airway pressure (Pmean), pulse oxygen saturation (SpO2), mean arterial pressure (MAP), heart rate (HR), central venous pressure (CVP), arterial blood gas, urine output (UO), the usage of sedation and muscle relaxation drugs were recorded. AVEA ventilator "turning point (Pflex) operation" was used to describe the quasi-static pressure volume curve (P-V curve). High and low inflection point (UIP, LIP) and triangular Pflex volume (Vdelta) were automatically measured and calculated. The ventilation parameters were set, and the 24-hour P-V curve was recorded again in order to be compared with subsequent results. Venous blood was collected before treatment, 24 hours and 48 hours after ventilation to measure lung surfactant protein D (SP-D) and large molecular mucus in saliva (KL-6) by enzyme linked immunosorbent assay (ELISA), and the correlation between the above two parameters and prognosis on 28 days was analyzed by multinomial logistic regression. Twenty-six patients with ALI/ARDS were enrolled, and 22 of them completed the test with 10 in APRV group and 12 in control group. The basic parameters and P-V curves between two groups were similar before

  20. Role of spousal involvement in continuous positive airway pressure (CPAP adherence in patients with obstructive sleep apnea (OSA

    Directory of Open Access Journals (Sweden)

    Batool-Anwar S

    2017-05-01

    Full Text Available Introduction: Little is known about the impact of spousal involvement on continuous positive airway pressure (CPAP adherence. The aim of this study was to determine whether spouse involvement affects adherence with CPAP therapy, and how this association varies with gender. Methods: 194 subjects recruited from Apnea Positive Pressure Long Term Efficacy Study (APPLES completed the Dyadic Adjustment Scale (DAS. The majority of participants were Caucasian (83%, and males (73%, with mean age of 56 years, mean BMI of 31 kg/m2. & 62% had severe OSA. The DAS is a validated 32-item self-report instrument measuring dyadic consensus, satisfaction, cohesion, and affectional expression. A high score in the DAS is indicative of a person’s adjustment to the marriage. Additionally, questions related to spouse involvement with general health and CPAP use were asked. CPAP use was downloaded from the device and self-report, and compliance was defined as usage > 4 h per night. Results: There were no significant differences in overall marital quality between the compliant and noncompliant subjects. However, level of spousal involvement was associated with increased CPAP adherence at 6 months (p=0.01. After stratifying for gender these results were significant only among males (p=0.03. Three years after completing APPLES, level of spousal involvement was not associated with CPAP compliance even after gender stratification. Conclusion: Spousal involvement is important in determining CPAP compliance in males in the 1st 6 months after initiation of therapy but is not predictive of longer-term adherence. Involvement of the spouse should be considered an integral part of CPAP initiation procedures.

  1. Slow loaded breathing training improves blood pressure, lung capacity and arm exercise endurance for older people with treated and stable isolated systolic hypertension.

    Science.gov (United States)

    Ublosakka-Jones, Chulee; Tongdee, Phailin; Pachirat, Orathai; Jones, David A

    2018-03-28

    Hypertension and reduced lung function are important features of aging. Slow loaded breathing training reduces resting blood pressure and the question is whether this can also improve lung function. Thirty-two people (67 ± 5 years, 16 male) with controlled isolated systolic hypertension undertook an eight weeks randomised controlled training trial with an inspiratory load of 25% maximum inspiratory pressure (MIP) at 6 breaths per minute (slow loaded breathing; SLB) or deep breathing control (CON). Outcome measures were resting blood pressure (BP) and heart rate; MIP; lung capacity; chest and abdominal expansion; arm cranking exercise endurance at 50% heart rate reserve. Home based measurement of resting systolic BP decreased by 20 mm Hg (15 to 25) (Mean and 95%CI) for SLB and by 5 mm Hg (1 to 7) for CON. Heart rate and diastolic BP also decreased significantly for SLB but not CON. MIP increased by 15.8 cm H 2 O (11.8 to 19.8) and slow vital capacity by 0.21 L (0.15 to 0.27) for SLB but not for CON. Chest and abdominal expansion increased by 2.3 cm (2.05 to 2.55) and 2.5 cm (2.15 to 2.85), respectively for SLB and by 0.5 cm (0.26 to 0.74) and 1.7 cm (1.32 to 2.08) for CON. Arm exercise time increased by 4.9 min (3.65 to 5.15) for SLB with no significant change for CON. Slow inspiratory muscle training is not only effective in reducing resting BP, even in older people with well controlled isolated systolic hypertension but also increases inspiratory muscle strength, lung capacity and arm exercise duration. Copyright © 2018. Published by Elsevier Inc.

  2. Work of breathing during lung-protective ventilation in patients with acute lung injury and acute respiratory distress syndrome: a comparison between volume and pressure-regulated breathing modes.

    Science.gov (United States)

    Kallet, Richard H; Campbell, Andre R; Dicker, Rochelle A; Katz, Jeffrey A; Mackersie, Robert C

    2005-12-01

    Pressure-control ventilation (PCV) and pressure-regulated volume-control (PRVC) ventilation are used during lung-protective ventilation because the high, variable, peak inspiratory flow rate (V (I)) may reduce patient work of breathing (WOB) more than the fixed V (I) of volume-control ventilation (VCV). Patient-triggered breaths during PCV and PRVC may result in excessive tidal volume (V(T)) delivery unless the inspiratory pressure is reduced, which in turn may decrease the peak V (I). We tested whether PCV and PRVC reduce WOB better than VCV with a high, fixed peak V (I) (75 L/min) while also maintaining a low V(T) target. Fourteen nonconsecutive patients with acute lung injury or acute respiratory distress syndrome were studied prospectively, using a random presentation of ventilator modes in a crossover, repeated-measures design. A target V(T) of 6.4 + 0.5 mL/kg was set during VCV and PRVC. During PCV the inspiratory pressure was set to achieve the same V(T). WOB and other variables were measured with a pulmonary mechanics monitor (Bicore CP-100). There was a nonsignificant trend toward higher WOB (in J/L) during PCV (1.27 + 0.58 J/L) and PRVC (1.35 + 0.60 J/L), compared to VCV (1.09 + 0.59 J/L). While mean V(T) was not statistically different between modes, in 40% of patients, V(T) markedly exceeded the lung-protective ventilation target during PRVC and PCV. During lung-protective ventilation, PCV and PRVC offer no advantage in reducing WOB, compared to VCV with a high flow rate, and in some patients did not allow control of V(T) to be as precise.

  3. Chest wall restriction limits high airway pressure-induced lung injury in young rabbits.

    Science.gov (United States)

    Hernandez, L A; Peevy, K J; Moise, A A; Parker, J C

    1989-05-01

    High peak inspiratory pressures (PIP) during mechanical ventilation can induce lung injury. In the present study we compare the respective roles of high tidal volume with high PIP in intact immature rabbits to determine whether the increase in capillary permeability is the result of overdistension of the lung or direct pressure effects. New Zealand White rabbits were assigned to one of three protocols, which produced different degrees of inspiratory volume limitation: intact closed-chest animals (CC), closed-chest animals with a full-body plaster cast (C), and isolated excised lungs (IL). The intact animals were ventilated at 15, 30, or 45 cmH2O PIP for 1 h, and the lungs of the CC and C groups were placed in an isolated lung perfusion system. Microvascular permeability was evaluated using the capillary filtration coefficient (Kfc). Base-line Kfc for isolated lungs before ventilation was 0.33 +/- 0.31 ml.min-1.cmH2O-1.100g-1 and was not different from the Kfc in the CC group ventilated with 15 cmH2O PIP. Kfc increased by 850% after ventilation with only 15 cmH2O PIP in the unrestricted IL group, and in the CC group Kfc increased by 31% after 30 cmH2O PIP and 430% after 45 cmH2O PIP. Inspiratory volume limitation by the plaster cast in the C group prevented any significant increase in Kfc at the PIP values used. These data indicate that volume distension of the lung rather than high PIP per se produces microvascular damage in the immature rabbit lung.

  4. Impact of continuous positive airway pressure on the pulmonary changes promoted by immersion in water

    Directory of Open Access Journals (Sweden)

    Danize Aparecida Rizzetti

    Full Text Available ABSTRACT Objective: To determine whether different levels of CPAP improve the lung volumes and capacities of healthy subjects immersed in water. Methods: This was a randomized clinical trial, conducted between April and June of 2016, involving healthy female volunteers who were using oral contraceptives. Three 20-min immersion protocols were applied: control (no CPAP; CPAP5 (CPAP at 5 cmH2O; and CPAP10 (CPAP at 10 cmH2O. We evaluated HR, SpO2, FVC, FEV1, the FEV1/FVC ratio, peak expiratory flow rate (PEFR, and FEF25-75% at three time points: pre-immersion; 10 min after immersion; and 10 min after the end of each protocol. Results: We evaluated 13 healthy volunteers. The CPAP10 protocol reversed the restrictive pattern of lung function induced by immersion in water, maintaining pulmonary volumes and capacities for a longer period than did the CPAP5 protocol. Conclusions: When the hemodynamic change causing a persistent lung disorder, only the application of higher positive pressures is effective in maintaining long-term improvements in the pulmonary profile.

  5. Impact of continuous positive airway pressure on the pulmonary changes promoted by immersion in water.

    Science.gov (United States)

    Rizzetti, Danize Aparecida; Quadros, Janayna Rodembuch Borba; Ribeiro, Bruna Esmerio; Callegaro, Letícia; Veppo, Aline Arebalo; Wiggers, Giulia Alessandra; Peçanha, Franck Maciel

    2017-01-01

    To determine whether different levels of CPAP improve the lung volumes and capacities of healthy subjects immersed in water. This was a randomized clinical trial, conducted between April and June of 2016, involving healthy female volunteers who were using oral contraceptives. Three 20-min immersion protocols were applied: control (no CPAP); CPAP5 (CPAP at 5 cmH2O); and CPAP10 (CPAP at 10 cmH2O). We evaluated HR, SpO2, FVC, FEV1, the FEV1/FVC ratio, peak expiratory flow rate (PEFR), and FEF25-75%) at three time points: pre-immersion; 10 min after immersion; and 10 min after the end of each protocol. We evaluated 13 healthy volunteers. The CPAP10 protocol reversed the restrictive pattern of lung function induced by immersion in water, maintaining pulmonary volumes and capacities for a longer period than did the CPAP5 protocol. When the hemodynamic change causing a persistent lung disorder, only the application of higher positive pressures is effective in maintaining long-term improvements in the pulmonary profile.

  6. Numerical Simulation for Mechanism of Airway Narrowing in Asthma

    Science.gov (United States)

    Bando, Kiyoshi; Yamashita, Daisuke; Ohba, Kenkichi

    A calculation model is proposed to examine the generation mechanism of the numerous lobes on the inner-wall of the airway in asthmatic patients and to clarify luminal occlusion of the airway inducing breathing difficulties. The basement membrane in the airway wall is modeled as a two-dimensional thin-walled shell having inertia force due to the mass, and the smooth muscle contraction effect is replaced by uniform transmural pressure applied to the basement membrane. A dynamic explicit finite element method is used as a numerical simulation method. To examine the validity of the present model, simulation of an asthma attack is performed. The number of lobes generated in the basement membrane increases when transmural pressure is applied in a shorter time period. When the remodeling of the basement membrane occurs characterized by thickening and hardening, it is demonstrated that the number of lobes decreases and the narrowing of the airway lumen becomes severe. Comparison of the results calculated by the present model with those measured for animal experiments of asthma will be possible.

  7. Randomized controlled trial comparing nasal intermittent positive pressure ventilation and nasal continuous positive airway pressure in premature infants after tracheal extubation

    Directory of Open Access Journals (Sweden)

    Daniela Franco Rizzo Komatsu

    Full Text Available Summary Objective: To analyze the frequency of extubation failure in premature infants using conventional mechanical ventilation (MV after extubation in groups subjected to nasal intermittent positive pressure ventilation (nIPPV and continuous positive airway pressure (nCPAP. Method: Seventy-two premature infants with respiratory failure were studied, with a gestational age (GA ≤ 36 weeks and birth weight (BW > 750 g, who required tracheal intubation and mechanical ventilation. The study was controlled and randomized in order to ensure that the members of the groups used in the research were chosen at random. Randomization was performed at the time of extubation using sealed envelopes. Extubation failure was defined as the need for re-intubation and mechanical ventilation during the first 72 hours after extubation. Results: Among the 36 premature infants randomized to nIPPV, six (16.6% presented extubation failure in comparison to 11 (30.5% of the 36 premature infants randomized to nCPAP. There was no statistical difference between the two study groups regarding BW, GA, classification of the premature infant, and MV time. The main cause of extubation failure was the occurrence of apnea. Gastrointestinal and neurological complications did not occur in the premature infants participating in the study. Conclusion: We found that, despite the extubation failure of the group of premature infants submitted to nIPPV being numerically smaller than in premature infants submitted to nCPAP, there was no statistically significant difference between the two modes of ventilatory support after extubation.

  8. Study into the use of continuous positive airway pressure in obstructive sleep apnoea-hypopnoea syndrome patients with daytime drowsiness

    Directory of Open Access Journals (Sweden)

    Clélia Maria Ribeiro Franco

    2009-03-01

    Full Text Available Background: Obstructive sleep apnoea-hypopnoea syndrome (OSAHS is a respiratory disorder with high morbidity and mortality. Continuous positive airway pressure (CPAP is the most commonly prescribed conservative treatment for adults with OSAHS. CPAP therapy normalises or decreases OSAHS symptoms and can reduce and prevent OSAHS complications. Aims: To evaluate adherence to nasal CPAP treatment and CPAP impact on daytime drowsiness. Method: A sample of 20 patients evaluated for daytime drowsiness using the Epworth sleepiness scale and interviewed for adherence to nasal CPAP use. Results: There was a significant decrease in the level of daytime sleepiness of the patients users of nasal CPAP (p=0.017; patients not using nasal CPAP experienced a decrease without statistical significance (p=0.162. 100% of CPAP users reported benefits and 50% of these reported related discomforts. Conclusions: Patients with OSAHS that use CPAP have a greater reduced level of sleepiness than those who do not use it. Resumo: Introdução: A síndroma da apneia-hipopneia obstrutiva do sono (SAHOS é um distúrbio respiratório de elevada morbimortalidade. A terapia com pressão positiva contínua das vias aéreas (CPAP representa o tratamento conservador mais prescrito para a SAHOS e tem o intuito de restabelecer a patência das vias aéreas, normalizando o índice de eventos respiratórios obstrutivos, corrigindo os sintomas. Objectivo: Avaliar o impacto do uso do CPAP nasal sobre a hipersonia diurna em portadores de SAHOS. Método: Amostra de vinte doentes portadores de SAHOS diagnosticados por estudo de polissonografia de noite inteira, usuários ou não de CPAP nasal, todos avaliados quanto à hipersonia diurna através da escala de sonolência de Epworth. Resultados: O decréscimo do nível de sonolência diurna dos usuários de CPAP nasal foi significante (p=0,017, enquanto para não usuários de CPAP nasal a m

  9. [Compliance with continuous positive airway pressure therapy in patients with sleep apnea/hypopnea syndrome].

    Science.gov (United States)

    Gallego, Claudio W; Dibur, Eduardo; Salomone, César; Di Bartolo, Carlos G

    2004-01-01

    Predictive factors and compliance level were evaluated in a group of patients with sleep apnea syndrome under CPAP treatment, assessing side effects and equipment condition: silicone interface (SI), mask-conectors (M-C), air tube (AT) and head strap (HS). Patients with >3mo treatment were included, clock counter reading was registered at the beginning, 2 and 4 mo. Patients were considered compliant (C+) when usage was >4h/day and >5day/week. Of 46 patients (male 34; age 62 +/- 9years; BMI 33 +/- 7kg/m2; AHI 38 +/- 18/h; time of therapy 2.1 +/- 1.7years; CPAP 9 +/- 1.4 cmH2O), 34 had a clock counter and 24 (71%) were C+. Initial symptoms included: somnolence (65%), snoring (39%), bed-partner witnessed apneas (28%). Comparing C+ and C- we didn't find significant difference in age, BMI, CPAP pressure, length of therapy, AHI and pre-treatment Epworth classification. Referred vs. measured time of use in C+ and C- were 6.6 +/- 1 vs. 6.1 +/- 1 h/d (p=0.02) and 5.6 +/- 1 vs. 2.4 +/- 1 h/d (pcongestion 27%, sleep disruption 11%, CPAP noisy 9%, dry nose, rhinorrhea and skin irritation 7%. Twenty seven percent of patients reduced the CPAP use because of the SE. Correction strategies included: humidifier, nasal steroid, surgery or infiltration of turbinates. Comparing the condition of SI, M-C, AT and HS between 1year of use, we observed a lower percentage of fine elements (87 to 44%, 74 to 44%, 83 to 44%, 91 to 78%, respectively). Most common defects included stiffness of SI, cracks in SI, M-C and AT, loose conexions. The study confirms the importance of objective monitoring in patients with CPAP. Side effects and equipment condition require special attention because this could affect an effective treatment.

  10. Restoring the salivary cortisol awakening response through nasal continuous positive airway pressure therapy in obstructive sleep apnea.

    Science.gov (United States)

    Ghiciuc, Cristina Mihaela; Dima Cozma, Lucia Corina; Bercea, Raluca Mihaela; Lupusoru, Catalina Elena; Mihaescu, Traian; Szalontay, Andreea; Gianfreda, Angela; Patacchioli, Francesca Romana

    2013-10-01

    Partial and largely conflicting data are currently available on the interplay between obstructive sleep apnea (OSA) and hypothalamus-pituitary-adrenal axis (HPA) activity in adult obese men. This study was performed to evaluate the daily trajectories of salivary cortisol, specifically with respect to the salivary cortisol awakening response (CAR), a common method used to assess HPA axis activity. The main findings of this study were that adult male obese subjects who were newly diagnosed with severe OSA showed the following: (1) a flattening of the CAR; (2) levels of cortisol at awakening that were lower than those of the controls; and (3) maintenance of the physiological circadian activity of the HPA axis, with the highest hormone concentrations produced in the morning and the lowest in the evening. This study was also designed to investigate the effects of 3 and 6 mos of treatment with continuous airways positive pressure (CPAP). CPAP use resulted in a significant recovery of the sleep patterns disrupted by OSA; moreover, mild neuropsychological signs of depression and anxiety in severe OSA patients were concomitantly progressively improved by CPAP treatment. Furthermore, this study reports that 3 and 6 mos of CPAP therapy restored the presence of CAR and was able to significantly reduce the difference in the morning cortisol levels between the OSA and control groups. In conclusion, we report here that compared with obese nonapneic matched controls, OSA patients present a dysregulation of HPA axis activity, as shown by the flattening of the diurnal pattern of cortisol production in response to repeated challenge due to hypoxia and sleep fragmentation. This dysregulation was especially detectable in the first hour after awakening and restored after 3 and 6 mos of treatment with CPAP.

  11. Effect of continuous positive airway pressure treatment for obstructive sleep apnoea on visual processing of degraded words.

    Science.gov (United States)

    Proudlove, Katie; Manuel, Ari; Hall, Rachel; Rieu, Romelie; Villarroel, Mauricio; Stradling, John

    2014-01-01

    In a previous uncontrolled study, continuous positive airway pressure (CPAP) therapy for obstructive sleep apnoea (OSA) improved vision in patients with diabetic macular oedema. We investigated whether the above improvement in vision (or visual processing) might have been due to reduced sleepiness, rather than a true improvement in retinal function. Twelve normal control subjects and 20 patients with OSA were tested for their ability to recognise degraded words, by means of a computer programme displaying 5-letter words every 4 s for 10 min, with variable amounts of the bottom half of the word missing; the percentage of the word necessary to achieve correct identification on average half the time was 'hunted' (the test score). All subjects were tested twice, 2-3 weeks apart; the OSA group after the commencement of CPAP. The Epworth Sleepiness Score (ESS) in patients was measured at the same visit. The test score at visit 1 was 26.7% for normal subjects and 31.6% for patients with OSA. At visit 2, the test score was 25.0% for normal subjects and 29.9% for patients with OSA. The groups showed a small and identical improvement over the trial period in the test score, of 1.7% (p = 0.01 and p = 0.03 for the normal and OSA groups, respectively). The group with OSA experienced a drop in ESS of 7.5 (SD 5.5) points following treatment. The small and identical improvement in both groups suggests only a similar learning effect rather than any improvement due to reduced sleepiness.

  12. Determination of new prediction formula for nasal continuous positive airway pressure in Turkish patients with obstructive sleep apnea syndrome.

    Science.gov (United States)

    Basoglu, Ozen K; Tasbakan, Mehmet Sezai

    2012-12-01

    Race/ethnicity may play an important role in determining body size, severity of obstructive sleep apnea syndrome (OSAS), and effective continuous positive airway pressure (CPAP) (Peff). Turkey is composed of different ethnic groups. Therefore, the aims of this study were to determine new prediction formula for CPAP (Ppred) in Turkish OSAS patients, validate performance of this formula, and compare with Caucasian and Asian formulas. Peff of 250 newly diagnosed moderate-to-severe OSAS patients were calculated by in-laboratory manual titration. Correlation and multiple linear regression analysis were used to model effects of ten anthropometric and polysomnographic variables such as neck circumference (NC) and oxygen desaturation index (ODI) on Peff. New formula was validated in different 130 OSAS patients and compared with previous formulas. The final prediction formula was [Formula: see text]. When Peff of control group was assessed, it was observed that mean Peff was 8.39 ± 2.00 cmH(2)O and Ppred was 8.23 ± 1.22 cmH(2)O. Ppred was within ±3 cmH(2)O of Peff in 96.2% patients. Besides, Peff was significantly correlated with new formula, and prediction formulas developed for Caucasian and Asian populations (r = 0.651, p < 0.001, r = 0.648, p < 0.001, and r = 0.622, p < 0.001, respectively). It is shown that level of CPAP can be successfully predicted from our prediction formula, using NC and ODI and validated in Turkish OSAS patients. New equation correlates with other formulas developed for Caucasian and Asian populations. Our simple formula including ODI, marker of intermittent hypoxia, may be used easily in different populations.

  13. The use of continuous positive airway pressure in preterm babies with respiratory distress syndrome: a report from Baghdad, Iraq.

    Science.gov (United States)

    Hameed, Numan Nafie; Abdul Jaleel, Ra'id Khalil; Saugstad, Ola Didrik

    2014-04-01

    To study maternal and neonatal risk factors related to outcome of preterm babies with respiratory distress syndrome (RDS) on Continuous Positive Airway Pressure (CPAP) in a tertiary Iraqi NICU. A prospective case study carried out from January 5, 2011 to January 5, 2012, on 70 preterm neonates with RDS who were started on CPAP. Maternal and infant variables of preterm babies with successful or failed CPAP therapy were compared. Seventy neonates, 44 (63%) males and 26 (37%) females were included. Mean (SD) gestation was 32.8 (2.8) weeks and mean (SD) birth weight was 1860 (656) g. Thirty-seven (52.9%) babies failed CPAP, of them 29 (78.3%) were started on mechanical ventilation. The variables associated with failure of CPAP were: Birth weight ≤1500 g, gestational age ≤30 weeks, white out on the chest X-ray, FiO2 ≥50% at 20 min of CPAP, PEEP ≥5.5 cm H2O. Mortality rates were 94.6% in CPAP failures versus 5.4% in CPAP successes (p = 0.001). In infants surviving till discharge, duration of hospital stay was longer in babies who were CPAP successes (9.6 ± 3.7 versus 3.0 ± 2.7 days, p = 0.001). Gestational age, birth weight, whiteout chest X-ray, and FiO2 are important predictive values for success of CPAP therapy. A larger prospective multicenter controlled trial is needed to determine the benefits and risks of CPAP and predictors of its failure in our setting. Our results may be useful for others practicing in similar settings as us.

  14. Nasal continuous positive airway pressure therapy in a non-tertiary neonatal unit: reduced need for up-transfers.

    Science.gov (United States)

    Kiran, Sai; Murki, Srinivas; Pratap, Oleti Tejo; Kandraju, Hemasree; Reddy, Anupama

    2015-02-01

    To evaluate the need for up-transfer after starting of nasal continuous positive airway pressure (n-CPAP) services in a Level II special newborn care unit (SNCU). Five hundred fifty infants admitted to Level II SNCU, 252 infants during one year prior to introduction of n-CPAP (retrospective data from case records and electronic data base) and 298 infants during one year after introduction of n-CPAP services (prospective data in predefined case reporting form) were evaluated in this before and after intervention trial. The primary outcome was proportion of infants needing up-transfers from Level II SNCU for any indication. Baseline demographic data like birth weight, gestation and other perinatal factors were similar between the two epochs. Among the infants admitted to Level II SNCU, up-transfer for any reason was significantly higher in the pre-CPAP epoch compared with CPAP epoch (n = 93, 36 % vs. n = 74, 24.8 %, p = 0.002, OR 0.56, 95 % CI 0.38 to 0.83). However parent desired up-transfers were similar between the two epochs (n = 9, 3 % vs. n = 16, 5 %, p = 0.40). Introduction of n-CPAP treatment modality reduced up-transfers in subgroups of very low birth weight infants (VLBW) (n = 20, 74 % vs. n = 15, 37 %, p = 0.003) and also in preterm infants (n = 50, 54 % vs. n = 34, 32 %, p = 0.002). Introduction of n-CPAP services in a non-tertiary care neonatal unit, significantly reduced the need for up-transfers, especially in VLBW and preterm infants.

  15. Prevalence and variability of use of home mechanical ventilators, positive airway pressure and oxygen devices in the Lombardy region, Italy.

    Science.gov (United States)

    Vitacca, Michele; Barbano, Luca; Colombo, Daniele; Leoni, Olivia; Guffanti, Enrico

    2018-01-29

    Few studies have analyzed the prevalence and accessibility of home mechanical ventilation (HMV) in Italy. We aimed to investigate the prevalence and prescription variability of HMV as well as of long-term oxygen therapy (LTOT) and continuous positive airway pressure (CPAP), in the Lombardy Region. Prescribing rates of HMV (both noninvasive and tracheostomies), CPAP (auto-CPAP, CPAP/other sleep machines) and LTOT (liquid-O2, O2-gas, concentrators) in the 15 Local Healthcare districts of Lombardy were gathered from billing data for 2012 and compared. Crude rates (per 100,000 population) and rates for the different healthcare districts were calculated. In 2012, 6325 patients were on HMV (crude prescription rate: 63/100,000) with a high variation across districts (8/100,000 in Milano 1 vs 150/100,000 in Pavia). There were 14,237 patients on CPAP (crude prescription rate: 142/100,000; CPAP/other sleep machines 95.3% vs auto-CPAP 4.7%) with also high intra-regional variation (56/100,000 in Mantova vs. 260/100,000 in Pavia). There were 21,826 patients on LTOT (prescription rate: 217/100,000 rate; liquid-O2 94%, O2-gas 2.08%, O2-concentrators 3.8%), with again high intra-regional variation (100/100,000 in Bergamo vs 410/100,000 in Valle Camonica). The crude rate of HMV prescriptions in Lombardy is very high, with a high intra-regional variability in prescribing HMV, LTOT and CPAP which is partly explainable by the accessibility to specialist centers with HMV/sleep-study facilities. Analysis of administrative data and variability mapping can help identify areas of reduced access for an improved standardization of services. An audit among Health Payer and prescribers to interpret the described huge variability could be welcomed.

  16. Effects of continuous positive airway pressure on energy intake in obstructive sleep apnea: A pilot sham-controlled study

    Science.gov (United States)

    Shechter, Ari; Kovtun, Kyle; St-Onge, Marie-Pierre

    2016-01-01

    Obesity is among the leading risk factors for obstructive sleep apnea (OSA). A reciprocal relationship between obesity and OSA has been proposed, which may be due to excessive food intake. We conducted a pilot study to test the effects of continuous positive airway pressure (CPAP) on energy intake (EI) in OSA patients using a sham-controlled crossover design. In-laboratory total daily EI was assessed after 2 mo of active and sham CPAP. Four men were enrolled (age ± SEM: 51.8 ± 2.1 y; body mass index: 31.5 ± 1.5 kg/m2). All received active treatment first. Meals (breakfast, lunch, dinner, snack) were served in excess portions at fixed times and additional palatable snacks were freely available throughout the day. Total EI was lower after active (3744 ± 511 kcal/d) vs. sham (4030 ± 456 kcal/d) CPAP but this difference was not significant (p = 0.51) due to variability in the free snack intake. When only fixed eating occasions were considered, daily EI was significantly lower in the active (3105 ± 513 kcal/d) vs. sham (3559 ± 420 kcal/d) condition (p = 0.006). This small pilot and feasibility study is the first to utilize a sham-controlled design to investigate the effects of CPAP treatment on objective measures of EI. Findings suggest that CPAP may cause a reduction in fixed meal intake. In demonstrating feasibility of study methodology, our study also suggests a larger randomized sham-controlled trial be conducted to fully characterize the effects of CPAP treatment on EI and energy balance overall. PMID:27769851

  17. Analysis of Exhaled Breath for Disease Detection

    Science.gov (United States)

    Amann, Anton; Miekisch, Wolfram; Schubert, Jochen; Buszewski, Bogusław; Ligor, Tomasz; Jezierski, Tadeusz; Pleil, Joachim; Risby, Terence

    2014-06-01

    Breath analysis is a young field of research with great clinical potential. As a result of this interest, researchers have developed new analytical techniques that permit real-time analysis of exhaled breath with breath-to-breath resolution in addition to the conventional central laboratory methods using gas chromatography-mass spectrometry. Breath tests are based on endogenously produced volatiles, metabolites of ingested precursors, metabolites produced by bacteria in the gut or the airways, or volatiles appearing after environmental exposure. The composition of exhaled breath may contain valuable information for patients presenting with asthma, renal and liver diseases, lung cancer, chronic obstructive pulmonary disease, inflammatory lung disease, or metabolic disorders. In addition, oxidative stress status may be monitored via volatile products of lipid peroxidation. Measurement of enzyme activity provides phenotypic information important in personalized medicine, whereas breath measurements provide insight into perturbations of the human exposome and can be interpreted as preclinical signals of adverse outcome pathways.

  18. Plethysmographic measurements of specific airway resistance in young children

    DEFF Research Database (Denmark)

    Bisgaard, Hans; Nielsen, Kim G

    2005-01-01

    allowed discrimination of young children with respiratory disease. Bronchial hyperresponsiveness can be determined with acceptable short-term and long-term repeatability and provides good discrimination between asthmatics and healthy young children. The effects of the major antiasthmatic therapies have......Validated methods for lung function measurements in young children are lacking. Plethysmographic measurement of specific airway resistance (sRaw) provides such a method applicable from 2 years of age. sRaw gauges airway resistance from the measurements of the pressure changes driving the airflow...... during tidal breathing. These measurements require no active cooperation and are therefore feasible in children from 2 years of age. The within-observer and between-observer variability of sRaw in young children compare favorably with alternative methods. Reference values are available for sRaw and have...

  19. Impediment in upper airway stabilizing forces assessed by phrenic nerve stimulation in sleep apnea patients

    Directory of Open Access Journals (Sweden)

    Vérin E

    2005-09-01

    Full Text Available Abstract Background The forces developed during inspiration play a key role in determining upper airway stability and the occurrence of nocturnal breathing disorders. Phrenic nerve stimulation applied during wakefulness is a unique tool to assess Upper airway dynamic properties and to measure the overall mechanical effects of the inspiratory process on UA stability. Objectives To compare the flow/pressure responses to inspiratory and expiratory twitches between sleep apnea subjects and normal subjects. Methods Inspiratory and expiratory twitches using magnetic nerve stimulation completed in eleven untreated sleep apnea subjects and ten normal subjects. Results In both groups, higher flow and pressure were reached during inspiratory twitches. The two groups showed no differences in expiratory twitch parameters. During inspiration, the pressure at which flow-limitation occurred was more negative in normals than in apneic subjects, but not reaching significance (p = 0.07. The relationship between pharyngeal pressure and flow adequately fitted with a polynomial regression model providing a measurement of upper airway critical pressure during twitch. This pressure significantly decreased in normals from expiratory to inspiratory twitches (-11.1 ± 1.6 and -15.7 ± 1.0 cm H2O respectively, 95% CI 1.6–7.6, p Conclusion Inspiratory-related upper airway dilating forces are impeded in sleep apnea patients.

  20. Can resistive breathing injure the lung? Implications for COPD exacerbations

    Directory of Open Access Journals (Sweden)

    Vassilakopoulos T

    2016-09-01

    Full Text Available Theodoros Vassilakopoulos, Dimitrios Toumpanakis Pulmonary and Critical Care Medicine, Medical School, National and Kapodistrian University of Athens, Greece Abstract: In obstructive lung diseases, airway inflammation leads to bronchospasm and thus resistive breathing, especially during exacerbations. This commentary discusses experimental evidence that resistive breathing per se (the mechanical stimulus in the absence of underlying airway inflammation leads to lung injury and inflammation (mechanotransduction. The potential implications of resistive breathing-induced mechanotrasduction in COPD exacerbations are presented along with the available clinical evidence. Keywords: resistive breathing, COPD, mechanotransduction, bronchoconstriction, inflammation

  1. Mechanisms of breathing instability in patients with obstructive sleep apnea.

    Science.gov (United States)

    Younes, Magdy; Ostrowski, Michele; Atkar, Raj; Laprairie, John; Siemens, Andrea; Hanly, Patrick

    2007-12-01

    The response to chemical stimuli (chemical responsiveness) and the increases in respiratory drive required for arousal (arousal threshold) and for opening the airway without arousal (effective recruitment threshold) are important determinants of ventilatory instability and, hence, severity of obstructive apnea. We measured these variables in 21 obstructive apnea patients (apnea-hypopnea index 91 +/- 24 h(-1)) while on continuous-positive-airway pressure. During sleep, pressure was intermittently reduced (dial down) to induce severe hypopneas. Dial downs were done on room air and following approximately 30 s of breathing hypercapneic and/or hypoxic mixtures, which induced a range of ventilatory stimulation before dial down. Ventilation just before dial down and flow during dial down were measured. Chemical responsiveness, estimated as the percent increase in ventilation during the 5(th) breath following administration of 6% CO(2) combined with approximately 4% desaturation, was large (187 +/- 117%). Arousal threshold, estimated as the percent increase in ventilation associated with a 50% probability of arousal, ranged from 40% to >268% and was chemical drive. Effective recruitment threshold, estimated as percent increase in pre-dial-down ventilation associated with a significant increase in dial-down flow, ranged from zero to >174% and was chemical drive, but instability results because of a low arousal threshold and a brisk increase in drive following brief reduction in alveolar ventilation.

  2. Treatment of upper airway resistance syndrome in adults: Where do we stand?

    Directory of Open Access Journals (Sweden)

    Luciana B.M. de Godoy

    2015-01-01

    Full Text Available Objective: To evaluate the available literature regarding Upper Airway Resistance Syndrome (UARS treatment. Methods: Keywords “Upper Airway Resistance Syndrome,” “Sleep-related Breathing Disorder treatment,” “Obstructive Sleep Apnea treatment” and “flow limitation and sleep” were used in main databases. Results: We found 27 articles describing UARS treatment. Nasal continuous positive airway pressure (CPAP has been the mainstay therapy prescribed but with limited effectiveness. Studies about surgical treatments had methodological limitations. Oral appliances seem to be effective but their efficacy is not yet established. Conclusion: Randomized controlled trials with larger numbers of patients and long-term follow-up are important to establish UARS treatment options.

  3. Effects of positive airway pressure therapy on cardiovascular and metabolic markers in males with obstructive sleep apnea

    Directory of Open Access Journals (Sweden)

    A. Feliciano

    2017-07-01

    Full Text Available Introduction: Obstructive sleep apnea syndrome (OSAS is associated with cardiovascular/metabolic complications. Some analytical parameters (homocysteine, glycemic and lipidic profiles are recognized markers of these consequences. Limited data is available on the association of these markers and OSAS's severity/response to positive airway pressure therapy (PAP. Material and methods: In this prospective study we analyzed polysomnographic and analytical data of male patients admitted to sleep laboratory. The aim was to evaluate metabolic/cardiovascular markers in snorers and OSAS patients, to relate with sleep parameters and PAP response. One-hundred and three patients were included, and 73 (71% were OSAS patients. OSAS patients were similar to snorers except for higher body mass index (BMI and dyslipidemia. Severe OSAS patients showed higher glycemia, HbA1c, insulin, and insulin resistance, and lower HDL cholesterol in comparison to mild–moderate (p < 0.05, p < 0.05, p < 0.001, p < 0.001, p < 0.05, respectively. Glycemic profile and triglycerides were slightly correlated with OSAS severity. 46 OSAS patients were submitted to 6 months of PAP, with a statistical decrease in mean values of homocysteine, glycemia, total and LDL cholesterol (p < 0.05, p < 0.05, p < 0.05, respectively, and in glycemia and LDL cholesterol in severe group only (p < 0.05, p < 0.05, respectively. Results: This study demonstrated an association between glucose metabolism parameters and triglycerides with OSAS severity underlying the complexity of the process leading to cardiovascular/metabolic complications in this disorder. Moreover, homocysteine, glycemic and lipidic profiles changed significantly after 6 months of PAP therapy in OSAS, supporting its cardiovascular and metabolic protective effect. Conclusion: Our study has reinforced the importance of analytical cardiovascular/metabolic evaluation as

  4. Erectile Dysfunction and Sexual Hormone Levels in Men With Obstructive Sleep Apnea: Efficacy of Continuous Positive Airway Pressure.

    Science.gov (United States)

    Zhang, Xiao-Bin; Lin, Qi-Chang; Zeng, Hui-Qing; Jiang, Xing-Tang; Chen, Bo; Chen, Xiao

    2016-01-01

    In this study, the prevalence of erectile dysfunction (ED) and serum sexual hormone levels were evaluated in men with obstructive sleep apnea (OSA). In these patients, the efficacy of continuous positive airway pressure (CPAP) was determined. The 207 men (mean age 44.0 ± 11.1 years) enrolled in the study were stratified within four groups based on their apnea-hypopnea index score: simple snoring (n = 32), mild OSA (n = 29), moderate OSA (n = 38), and severe OSA (n = 108). The International Index of Erectile Dysfunction-5 (IIEF-5) score was obtained from each patient, and blood samples for the analysis of sexual hormones (prolactin, luteotropin, follicle-stimulating hormone, estradiol, progestin, and testosterone) were drawn in the morning after polysomnography. The IIEF-5 test and serum sexual hormone measurements were repeated after 3 months of CPAP treatment in 53 men with severe OSA. The prevalence of ED was 60.6 % in OSA patients overall and 72.2 % in those with severe OSA. Compared with the simple snoring group, patients with severe OSA had significantly lower testosterone levels (14.06 ± 5.62 vs. 17.02 ± 4.68, p = .018) and lower IIEF-5 scores (16.33 ± 6.50 vs. 24.09 ± 1.94, p = .001). The differences in the other sexual hormones between groups were not significant. After 3 months of CPAP treatment, there were no significant changes in sexual hormone levels, but the IIEF-5 score had improved significantly (18.21 ± 4.05 vs. 19.21 ± 3.86, p = .001). Severe OSA patients have low testosterone concentration and high ED prevalence. IIEF-5 scores increased significantly after CPAP treatment, but there was no effect on serum testosterone levels.

  5. Obstructive sleep apnea is associated with increased QT corrected interval dispersion: the effects of continuous positive airway pressure.

    Science.gov (United States)

    Bilal, Nagihan; Dikmen, Nursel; Bozkus, Fulsen; Sungur, Aylin; Sarica, Selman; Orhan, Israfil; Samur, Anil

    2017-03-31

    Severe obstructive sleep apnea (OSA) is associated with increased QT corrected interval dispersion (QTcd) and continuous positive airway pressure (CPAP) is thought to improve this arrhythmogenic marker. The aim of the study was to determine the decrease of ratio of cardiovascular risk in patients with obstructive sleep apnea. The study included 65 patients with severe OSA who had an apnea-hypopnea index (AHI) score of >30. Each patient underwent 12-channel electrocardiogram (ECG) monitoring and polysomnography. Patients with an AHI score of <5 were used as the control group. The control group also underwent ECG monitoring and polysomnography testing. The QTcd levels of both groups were calculated. Three months after CPAP treatment, ECG recordings were obtained from the 65 patients with severe OSA again, and their QTcd values were calculated. There were 44 male and 21 female patients with severe OSA syndrome. The age, gender, body mass index, initial saturation, minimum saturation, average saturation, and desaturation index were determined in both groups. The QTc intervals of the OSA patients (62.48±16.29ms) were significantly higher (p=0.001) than those of the control group (29.72±6.30ms). There were statistically significant differences between the QTc values before and after the CPAP treatment, with pretreatment QTc intervals of 62.48±16.29ms and 3-month post-treatment values of 41.42±16.96ms (p=0.001). There was a positive and significant correlation between QTcd periods and the AHI and hypopnea index (HI) in OSA patients (p=0.001; r=0.71; p=0.001; r=0.679, respectively). CPAP treatment reduced the QTcd in patients with severe OSA. In addition, shortening the QTcd periods in patients with severe OSA may reduce their risk of arrhythmias and cardiovascular disease. Copyright © 2017 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  6. Canadian Thoracic Society 2011 Guideline Update: Diagnosis and Treatment of Sleep Disordered Breathing

    Directory of Open Access Journals (Sweden)

    John Fleetham

    2011-01-01

    Full Text Available The Canadian Thoracic Society (CTS published an executive summary of guidelines for the diagnosis and treatment of sleep disordered breathing in 2006/2007. These guidelines were developed during several meetings by a group of experts with evidence grading based on committee consensus. These guidelines were well received and the majority of the recommendations remain unchanged. The CTS embarked on a more rigorous process for the 2011 guideline update, and addressed eight areas that were believed to be controversial or in which new data emerged. The CTS Sleep Disordered Breathing Committee posed specific questions for each area. The recommendations regarding maximum assessment wait times, portable monitoring, treatment of asymptomatic adult obstructive sleep apnea patients, treatment with conventional continuous positive airway pressure compared with automatic continuous positive airway pressure, and treatment of central sleep apnea syndrome in heart failure patients replace the recommendations in the 2006/2007 guidelines. The recommendations on bariatric surgery, complex sleep apnea and optimum positive airway pressure technologies are new topics, which were not covered in the 2006/2007 guidelines.

  7. A possible way to assess tidal exhaled nitric oxide in neonates and infants treated with nasal continuous positive airway pressure

    DEFF Research Database (Denmark)

    Schmidt, Birgitte Johanne; Reim, Pauline Schibler; Pedersen, Ole Find

    2018-01-01

    The endogenous compound nitric oxide (NO) is released into the airways via inducible NO synthase (1),which has the capacity to produce NO when up-regulated by pro-inflammatory cytokines or exogenous factors, like hypoxia, bacterial toxins and viruses (2). Prematurely born infants are susceptible...

  8. Enhanced airway dilation by positive-pressure inflation of the lungs compared with active deep inspiration in patients with asthma

    NARCIS (Netherlands)

    Slats, Annelies M.; Janssen, Kirsten; de Jeu, Ronald C.; van der Plas, Dirk T.; Schot, Robert; van den Aardweg, Joost G.; Sterk, Peter J.

    2008-01-01

    Deep inspiration temporarily reduces induced airways obstruction in healthy subjects. This bronchodilatory effect of deep inspiration is impaired in asthma. Passive machine-assisted lung inflation may augment bronchodilation compared with an active deep inspiration in patients with asthma by either

  9. Effects of short-term pressure-controlled ventilation on gas exchange, airway pressures, and gas distribution in patients with acute lung injury/ARDS: comparison with volume-controlled ventilation.

    Science.gov (United States)

    Prella, Maura; Feihl, François; Domenighetti, Guido

    2002-10-01

    The potential clinical benefits of pressure-controlled ventilation (PCV) over volume-controlled ventilation (VCV) in patients with acute lung injury (ALI) or ARDS still remain debated. We compared PCV with VCV in patients with ALI/ARDS with respect to the following physiologic end points: (1) gas exchange and airway pressures, and (2) CT scan intrapulmonary gas distribution at end-expiration. Prospective, observational study. A multidisciplinary ICU in a nonuniversity, acute-care hospital. Ten patients with ALI or ARDS (9 men and 1 woman; age range, 17 to 80 years). Sequential ventilation in PCV and VCV with a constant inspiratory/expiratory ratio, tidal volume, respiratory rate, and total positive end-expiratory pressure; measurement of gas exchange and airway pressures; and achievement of CT sections at lung base, hilum, and apex for the quantitative analysis of lung densities and of aerated vs nonaerated zones. PaO(2), PaCO(2), and PaO(2)/fraction of inspired oxygen ratio levels did not differ between PCV and VCV. Peak airway pressure (Ppeak) was significantly lower in PCV compared with VCV (26 +/- 2 cm H(2)O vs 31 +/- 2 cm H(2)O; p mean +/- SEM). The surface areas of the nonaerated zones as well as the total areas at each section level were unchanged in PCV compared with VCV, except at the apex level, where there was a significantly greater nonaerated area in VCV (11 +/- 2 cm(2) vs 9 +/- 2 cm(2); p mean CT number of each lung (20 lungs from 10 patients) was similar in the two modes, as were the density values at the basal and apical levels; the hilum mean CT number was - 442 +/- 28 Hounsfield units (HU) in VCV and - 430 +/- 26 HU in PCV (p lower Ppeaks through the precise titration of the lung distending pressure, and might be applied to avoid regional overdistension by means of a more homogeneous gas distribution.

  10. The effects of breath-holding on pulmonary regurgitation measured by cardiovascular magnetic resonance velocity mapping

    Directory of Open Access Journals (Sweden)

    Babu-Narayan Sonya V

    2009-01-01

    Full Text Available Abstract Background Pulmonary regurgitation is a common and clinically important residual lesion after repair of tetralogy of Fallot. Cardiovascular magnetic resonance (CMR phase contrast velocity mapping is widely used for measurement of pulmonary regurgitant fraction. Breath-hold acquisitions, usually acquired during held expiration, are more convenient than the non-breath-hold approach, but we hypothesized that breath-holding might affect the amount of pulmonary regurgitation. Methods Forty-three adult patients with a previous repair of tetralogy of Fallot and residual pulmonary regurgitation were investigated with CMR. In each, pulmonary regurgitant fraction was measured from velocity maps transecting the pulmonary trunk, acquired during held expiration, held inspiration, by non-breath-hold acquisition, and also from the difference of right and left ventricular stroke volume measurements. Results Pulmonary regurgitant fraction was lower when measured by velocity mapping in held expiration compared with held inspiration, non-breath-hold or stroke volume difference (30.8 vs. 37.0, 35.6, 35.4%, p = 0.00017, 0.0035, 0.026. The regurgitant volume was lower in held expiration than in held inspiration (41.9 vs. 48.3, p = 0.0018. Pulmonary forward flow volume was larger during held expiration than during non-breath-hold (132 vs. 124 ml, p = 0.0024. Conclusion Pulmonary regurgitant fraction was significantly lower in held expiration compared with held inspiration, free breathing and stroke volume difference. Altered airway pressure could be a contributory factor. This information is relevant if breath-hold acquisition is to be substituted for non-breath-hold in the investigation of patients with a view to re-intervention.

  11. Airway malacia in children with achondroplasia.

    Science.gov (United States)

    Dessoffy, Kimberly E; Modaff, Peggy; Pauli, Richard M

    2014-02-01

    This study was undertaken to assess the frequency of airway malacia in infants and young children with achondroplasia, a population well known to be at risk for a variety of respiratory problems. We also wished to evaluate what, if any, contribution airway malacia makes to the complex respiratory issues that may be present in those with achondroplasia. Retrospective chart review of all infants and young children with achondroplasia who were assessed through the Midwest Regional Bone Dysplasia Clinics from 1985 through 2012 (n = 236) was completed. Records of comprehensive clinical examinations, polysomnographic assessments, and airway visualization were reviewed and abstracted using a data collection form. Analyses were completed comparing the group with and those without evidence for airway malacia. Thirteen of 236 patients (5.5%) were found to have airway malacia. Most of those affected had lower airway involvement (9/13). The presence of airway malacia was correlated with an increased occurrence of obstructive sleep apnea as well as need for oxygen supplementation, airway surgeries and tracheostomy placement. Although estimates of the frequency of airway malacia in the general population are limited, its frequency in children with achondroplasia appears to be much higher than any published general population estimate. The presence of airway malacia appears to confound other breathing abnormalities in this population and results in the need for more invasive airway treatments. © 2013 Wiley Periodicals, Inc.

  12. Auto-titrating versus fixed continuous positive airway pressure for the treatment of obstructive sleep apnea: a systematic review with meta-analyses

    Directory of Open Access Journals (Sweden)

    Ip Stanley

    2012-03-01

    Full Text Available Abstract Background Obstructive sleep apnea is a relatively common disorder that can lead to lost productivity and cardiovascular disease. The form of positive airway treatment that should be offered is unclear. Methods MEDLINE and the Cochrane Central Trials registry were searched for English language randomized controlled trials comparing auto-titrating positive airway pressure (APAP with continuous positive airway pressure (CPAP in adults with obstructive sleep apnea (inception through 9/2010. Six researchers extracted information on study design, potential bias, patient characteristics, interventions and outcomes. Data for each study were extracted by one reviewer and confirmed by another. Random effects model meta-analyses were performed for selected outcomes. Results Twenty-four randomized controlled trials met the inclusion criteria. In individual studies, APAP and fixed CPAP resulted in similar changes from baseline in the apnea-hypopnea index, most other sleep study measures and quality of life. By meta-analysis, APAP improved compliance by 11 minutes per night (95% CI, 3 to 19 minutes and reduced sleepiness as measured by the Epworth Sleepiness Scale by 0.5 points (95% CI, 0.8 to 0.2 point reduction compared with fixed CPAP. Fixed CPAP improved minimum oxygen saturation by 1.3% more than APAP (95% CI, 0.4 to 2.2%. Studies had relatively short follow-up and generally excluded patients with significant comorbidities. No study reported on objective clinical outcomes. Conclusions Statistically significant differences were found but clinical importance is unclear. Because the treatment effects are similar between APAP and CPAP, the therapy of choice may depend on other factors such as patient preference, specific reasons for non-compliance and cost.

  13. Use of Respiratory Support in the Biphase Ventilation Airway Mode in the Newborn

    Directory of Open Access Journals (Sweden)

    S. N. Koval

    2006-01-01

    Full Text Available Biphasic positive airway pressure (BIPAP (also known as DuoPAP, BiLevel, BiVent, PCV+, SPAP is a mode of ventilation with cycling variations between two continuous positive airway pressure levels. It is a mixture of pressure controlled ventilation and spontaneous breathing, which is unrestricted in each phase of the respiratory cycle. The volume displacement caused by the difference between Phigh and Plow airway pressure level. The phase time ratio (PTR — the BIPAP frequency is calculated as the ratio between the durations of the two pressure phases, a PTR greater than 1:1 is called APRV (airway pressure release ventilation. In patients with ARDS maintained spontaneous breathing with BIPAP resulted in lower venous admixture and better arterial blood oxygenation as compared with A/C. Only a few studies with BIPAP have been performed in newborn and infants until now. We studied the use of BIPAP in newborn (body mass > 3kg and randomised 40 patients with respiratory failure for ventilation with BIPAP (n=20 or conventional mechanical ventilatory support (assist-control A/C — synchronised intermittent mandatory ventilation (SIMV (n=20. The Pediatric Risk of Mortality score (PRISM were collected for each patient. Fentanyl, diazepam, GABA were used as sedatives and adjusted in accordance with the Cook scale. We compared ventilatory parameters, information pertaining to pulmonary function and oxygen delivery, cardiac output, additional descriptors of organ system functions, duration and complications of ventilation and number and dosages of sedatives administered. All the patients that we intended to ventilate with BIPAP were successfully ventilated, we can conclude that biphasic ventilatory support suitable mode of ventilation for newborn with a decreased need of analgetics and sedatives than A/C. Finally, BIPAP is an a effective safe, and easy to use for personal mode of mechanical ventilatory support in newborn. 

  14. Clearing the airway by an emergency care provider in the prehospital emergency care

    OpenAIRE

    NOVOTNÁ, Magdalena

    2008-01-01

    Clearing an obstructed airway to facilitate breathing is a critical element of airway management. It is the emergency care provider who administers first aid and he/she has to master the technique of opening the airway as well as the aspiration prevention. The right airway management may avert the life-threatening condition of an injured person. The thesis is focused on the possibilities of clearing the airway by the emergency care provider in the Central Bohemian region. Techniques of openin...

  15. Effect Of Pressure Support Versus Unassisted Breathing Through A Tracheostomy Collar On Weaning Duration In Patients Requiring Prolonged Mechanical Ventilation: A Randomized Trial

    Science.gov (United States)

    Jubran, Amal; Grant, Brydon J.B.; Duffner, Lisa A.; Collins, Eileen G.; Lanuza, Dorothy M.; Hoffman, Leslie A.; Tobin, Martin J.

    2013-01-01

    Context Patients requiring prolonged mechanical ventilation (more than 21 days) are commonly weaned at long-term acute care hospitals (LTACHs). The most effective method of weaning such patients has not been investigated. Objective To compare weaning duration with pressure support versus unassisted breathing through a tracheostomy (trach collar) in patients transferred to a LTACH for weaning from prolonged ventilation. Design, Settings, and Participants Between 2000 and 2010, a randomized study was conducted in tracheotomized patients transferred to a single LTACH for weaning from prolonged ventilation. Of 500 patients who underwent a five-day screening procedure, 316 failed and were randomly assigned to wean with pressure support (n=155) or a trach collar (n=161). Six- and twelve-month survival was also determined. Main outcome measure Primary outcome was weaning duration. Secondary outcome was survival at six and twelve months after enrollment. Results Of 316 patients, four were withdrawn and not included in analysis. Of 152 patients in the pressure-support arm, 68 (44.7%) were weaned; 22 (14.5%) died. Of 160 patients in the trach-collar arm, 85 (53.1%) were weaned; 16 (10.0%) died. Median weaning time was shorter with trach collar than with pressure support: 15 [interquartile range, 8–25] versus 19 [12–31] days, p=0.004. The hazard ratio (HR) for successful weaning rate was higher with trach collar than with pressure support (HR, 1.43; 95% confidence interval [CI], 1.03–1.98, p<0.03) after adjusting for baseline clinical covariates. Trach collar achieved faster weaning than did pressure support among subjects who failed the screening procedure at 12–120 hours (HR, 3.33; 95% CI, 1.44–7.70, p<0.01), whereas weaning time was equivalent with the two methods in patients who failed the screening procedure within 0–12 hours. Mortality was equivalent in the pressure-support and trach-collar arms at six months (55.9% versus 51.3%; 4.7 difference, 95% CI −6

  16. Effect of pressure support vs unassisted breathing through a tracheostomy collar on weaning duration in patients requiring prolonged mechanical ventilation: a randomized trial.

    Science.gov (United States)

    Jubran, Amal; Grant, Brydon J B; Duffner, Lisa A; Collins, Eileen G; Lanuza, Dorothy M; Hoffman, Leslie A; Tobin, Martin J

    2013-02-20

    Patients requiring prolonged mechanical ventilation (>21 days) are commonly weaned at long-term acute care hospitals (LTACHs). The most effective method of weaning such patients has not been investigated. To compare weaning duration with pressure support vs unassisted breathing through a tracheostomy collar in patients transferred to an LTACH for weaning from prolonged ventilation. Between 2000 and 2010, a randomized study was conducted in tracheotomized patients transferred to a single LTACH for weaning from prolonged ventilation. Of 500 patients who underwent a 5-day screening procedure, 316 did not tolerate the procedure and were randomly assigned to receive weaning with pressure support (n = 155) or a tracheostomy collar (n = 161). Survival at 6- and 12-month time points was also determined. Primary outcome was weaning duration. Secondary outcome was survival at 6 and 12 months after enrollment. Of 316 patients, 4 were withdrawn and not included in analysis. Of 152 patients in the pressure-support group, 68 (44.7%) were weaned; 22 (14.5%) died. Of 160 patients in the tracheostomy collar group, 85 (53.1%) were weaned; 16 (10.0%) died. Median weaning time was shorter with tracheostomy collar use (15 days; interquartile range [IQR], 8-25) than with pressure support (19 days; IQR, 12-31), P = .004. The hazard ratio (HR) for successful weaning rate was higher with tracheostomy collar use than with pressure support (HR, 1.43; 95% CI, 1.03-1.98; P = .033) after adjusting for baseline clinical covariates. Use of the tracheostomy collar achieved faster weaning than did pressure support among patients who did not tolerate the screening procedure between 12 and 120 hours (HR, 3.33; 95% CI, 1.44-7.70; P = .005), whereas weaning time was equivalent with the 2 methods in patients who did not tolerate the screening procedure within 0 to 12 hours. Mortality was equivalent in the pressure-support and tracheostomy collar groups at 6 months (55.92% vs 51.25%; 4.67% difference, 95

  17. An expiratory assist during spontaneous breathing can compensate for endotracheal tube resistance.

    Science.gov (United States)

    Uchiyama, Akinori; Chang, Cheng; Suzuki, Shinya; Mashimo, Takashi; Fujino, Yuji

    2009-08-01

    Although inspiratory assist of spontaneous breathing in intubated patients is common, expiratory assist functions have rarely been reported. Effective expiratory support (ES) could be used to compensate for endotracheal tube (ETT) resistance during spontaneous breathing. In this study, we examined the performance of a new system designed to provide both inspiratory support (IS) and ES during spontaneous breathing with the goal of reducing the effective resistance of the ETT. The ES system consisted of a ventilator demand valve and a computer-controlled piston cylinder, which aspirated gas from the respiratory circuit during the expiratory phase. The movement of the piston was synchronized with spontaneous breathing. We compared the pressures at the tip of the ETT and in the breathing circuit during spontaneous breathing through an ETT of internal diameter (ID) 5 mm with that of an ETT with ID 8 mm in nine healthy adult male volunteers. The ventilatory mode was set to maintain a continuous airway pressure of 0 cm H(2)O. Three ventilator settings (no support, IS only, and IS plus ES) were compared using ID 5 mm ETT. We monitored pressure in the breathing circuit (P(aw)), ETT tip pressure (P(tip)), and respiratory flow. The P(tip) of the ID 5 mm ETT showed a large negative deflection during inspiration and a positive deflection during expiration without support. IS alone did not improve the respiratory pattern through the small ETT. However, IS plus ES resulted in negative P(aw) during expiration in addition to positive deflection of P(aw) during inspiration, making the pressure characteristics of P(tip) similar to those of ID 8 mm ETT. Moreover, IS plus ES produced a respiratory pattern through the ID 5 mm ETT that was similar to that through the ID 8 mm ETT. In this study of healthy volunteers, IS plus ES compensated for the airway resistance imposed by a ID 5.0 mm ETT to create pressure changes at the tip of the ETT similar to those of an ID 8.0 mm ETT.

  18. [Treatment compliance with continuous positive airway pressure device among adults with obstructive sleep apnea (OSA): how many adhere to treatment?].

    Science.gov (United States)

    Sarrell, E Michael; Chomsky, Ofer; Shechter, Dalia

    2013-03-01

    Obstructive sleep apnea syndrome (OSA) afflicts approximately 5% of the adult population and increases with age. The gold standard treatment is with the Continuous Positive Airways Pressure (CPAP) machine. Well-designed prospective trials to elucidate long term compliance with CPAP machine are rare. Assessing compliance and long-term use of CPAP machines among patients with OSA who were referred for treatment with this machine. A 4 years prospective cohort observational study was conducted using telephone interviews of 371 newly diagnosed patients with moderate to severe OSA, who received a specialist recommendation to use the CPAP machine which was bought and adjusted to their use. At the end of the first year, 126 (34%) of the OSA patients used the CPAP machine on a nightly basis (regular users), 120 (32.3%) had not used it at all, and 125 (33.7%) had used it only intermittently. The number of regular users increased between the 1st and 2nd year from 126 (34%), to 163 (44%) (p < 0.07) due to additions from the intermittent users group. The non-users group grew from 120 (32.3%) in the first year, and every year afterwards, up to 221 (59.6%) in the fourth year (p < 0.02). In contrast, there was a significant decrease in the intermittent users group, which declined from 125 (33.7%) in the first year to only 18 (4.8%) in the 4th year (p < 0.005). Most of the patients (92.9%) were males. The average age of the regular users was 59.6 years (+/- 11), which was higher in comparison to 55.9 years (+/- 10.3) for the non-users or 58.9 years (+/- 12.6) among the intermittent users (p = 0.064). There were no statistical differences in co-morbidities or demographics between the three groups. However, the regular users were found to have a higher score in the Epworth Sleepiness Scale (ESS) and a minimal arterial oxygen saturation (SaO2) level lower than the patients in the non-users and intermittent users groups (p = 0.019 and p = 0.03 respectively). Four years follow

  19. The role of high airway pressure and dynamic strain on ventilator-induced lung injury in a heterogeneous acute lung injury model.

    Science.gov (United States)

    Jain, Sumeet V; Kollisch-Singule, Michaela; Satalin, Joshua; Searles, Quinn; Dombert, Luke; Abdel-Razek, Osama; Yepuri, Natesh; Leonard, Antony; Gruessner, Angelika; Andrews, Penny; Fazal, Fabeha; Meng, Qinghe; Wang, Guirong; Gatto, Louis A; Habashi, Nader M; Nieman, Gary F

    2017-12-01

    Acute respiratory distress syndrome causes a heterogeneous lung injury with normal and acutely injured lung tissue in the same lung. Improperly adjusted mechanical ventilation can exacerbate ARDS causing a secondary ventilator-induced lung injury (VILI). We hypothesized that a peak airway pressure of 40 cmH 2 O (static strain) alone would not cause additional injury in either the normal or acutely injured lung tissue unless combined with high tidal volume (dynamic strain). Pigs were anesthetized, and heterogeneous acute lung injury (ALI) was created by Tween instillation via a bronchoscope to both diaphragmatic lung lobes. Tissue in all other lobes was normal. Airway pressure release ventilation was used to precisely regulate time and pressure at both inspiration and expiration. Animals were separated into two groups: (1) over-distension + high dynamic strain (OD + H DS , n = 6) and (2) over-distension + low dynamic strain (OD + L DS , n = 6). OD was caused by setting the inspiratory pressure at 40 cmH 2 O and dynamic strain was modified by changing the expiratory duration, which varied the tidal volume. Animals were ventilated for 6 h recording hemodynamics, lung function, and inflammatory mediators followed by an extensive necropsy. In normal tissue (N T ), OD + L DS caused minimal histologic damage and a significant reduction in BALF total protein (p < 0.05) and MMP-9 activity (p < 0.05), as compared with OD + H DS . In acutely injured tissue (ALI T ), OD + L DS resulted in reduced histologic injury and pulmonary edema (p < 0.05), as compared with OD + H DS . Both N T and ALI T are resistant to VILI caused by OD alone, but when combined with a H DS , significant tissue injury develops.

  20. Bad Breath

    Science.gov (United States)

    ... garlic, onions, cheese, orange juice, and soda poor dental hygiene (say: HI-jeen), meaning not brushing and flossing regularly smoking and other tobacco use Poor oral hygiene leads to bad breath because when food particles ...

  1. Breathing Difficulties

    Science.gov (United States)

    ... symptoms. Symptoms associated with weak respiratory muscles: Air “hunger” (gasping, labored breathing) with an without activity Fatigue ... Start your own fundraising event & help create a world without ALS Start an Event Site Map | Press ...

  2. Bad Breath

    Science.gov (United States)

    ... cabbage. And of course smoking causes its own bad smell. Some diseases and medicines can cause a specific breath odor. Having good dental habits, like brushing and flossing regularly, help fight bad ...

  3. A 4DCT imaging-based breathing lung model with relative hysteresis

    Energy Technology Data Exchange (ETDEWEB)

    Miyawaki, Shinjiro; Choi, Sanghun [IIHR – Hydroscience & Engineering, The University of Iowa, Iowa City, IA 52242 (United States); Hoffman, Eric A. [Department of Biomedical Engineering, The University of Iowa, Iowa City, IA 52242 (United States); Department of Medicine, The University of Iowa, Iowa City, IA 52242 (United States); Department of Radiology, The University of Iowa, Iowa City, IA 52242 (United States); Lin, Ching-Long, E-mail: ching-long-lin@uiowa.edu [IIHR – Hydroscience & Engineering, The University of Iowa, Iowa City, IA 52242 (United States); Department of Mechanical and Industrial Engineering, The University of Iowa, 3131 Seamans Center, Iowa City, IA 52242 (United States)

    2016-12-01

    To reproduce realistic airway motion and airflow, the authors developed a deforming lung computational fluid dynamics (CFD) model based on four-dimensional (4D, space and time) dynamic computed tomography (CT) images. A total of 13 time points within controlled tidal volume respiration were used to account for realistic and irregular lung motion in human volunteers. Because of the irregular motion of 4DCT-based airways, we identified an optimal interpolation method for airway surface deformation during respiration, and implemented a computational solid mechanics-based moving mesh algorithm to produce smooth deforming airway mesh. In addition, we developed physiologically realistic airflow boundary conditions for both models based on multiple images and a single image. Furthermore, we examined simplified models based on one or two dynamic or static images. By comparing these simplified models with the model based on 13 dynamic images, we investigated the effects of relative hysteresis of lung structure with respect to lung volume, lung deformation, and imaging methods, i.e., dynamic vs. static scans, on CFD-predicted pressure drop. The effect of imaging method on pressure drop was 24 percentage points due to the differences in airflow distribution and airway geometry. - Highlights: • We developed a breathing human lung CFD model based on 4D-dynamic CT images. • The 4DCT-based breathing lung model is able to capture lung relative hysteresis. • A new boundary condition for lung model based on one static CT image was proposed. • The difference between lung models based on 4D and static CT images was quantified.

  4. Sustained inflation and incremental mean airway pressure trial during conventional and high-frequency oscillatory ventilation in a large porcine model of acute respiratory distress syndrome

    Directory of Open Access Journals (Sweden)

    Wunder Christian

    2006-06-01

    Full Text Available Abstract Background To compare the effect of a sustained inflation followed by an incremental mean airway pressure trial during conventional and high-frequency oscillatory ventilation on oxygenation and hemodynamics in a large porcine model of early acute respiratory distress syndrome. Methods Severe lung injury (Ali was induced in 18 healthy pigs (55.3 ± 3.9 kg, mean ± SD by repeated saline lung lavage until PaO2 decreased to less than 60 mmHg. After a stabilisation period of 60 minutes, the animals were randomly assigned to two groups: Group 1 (Pressure controlled ventilation; PCV: FIO2 = 1.0, PEEP = 5 cmH2O, VT = 6 ml/kg, respiratory rate = 30/min, I:E = 1:1; group 2 (High-frequency oscillatory ventilation; HFOV: FIO2 = 1.0, Bias flow = 30 l/min, Amplitude = 60 cmH2O, Frequency = 6 Hz, I:E = 1:1. A sustained inflation (SI; 50 cmH2O for 60s followed by an incremental mean airway pressure (mPaw trial (steps of 3 cmH2O every 15 minutes were performed in both groups until PaO2 no longer increased. This was regarded as full lung inflation. The mPaw was decreased by 3 cmH2O and the animals reached the end of the study protocol. Gas exchange and hemodynamic data were collected at each step. Results The SI led to a significant improvement of the PaO2/FiO2-Index (HFOV: 200 ± 100 vs. PCV: 58 ± 15 and TAli: 57 ± 12; p 2-reduction (HFOV: 42 ± 5 vs. PCV: 62 ± 13 and TAli: 55 ± 9; p Ali: 6.1 ± 1 vs. T75: 3.4 ± 0.4; PCV: TAli: 6.7 ± 2.4 vs. T75: 4 ± 0.5; p Conclusion A sustained inflation followed by an incremental mean airway pressure trial in HFOV improved oxygenation at a lower mPaw than during conventional lung protective ventilation. HFOV but not PCV resulted in normocapnia, suggesting that during HFOV there are alternatives to tidal ventilation to achieve CO2-elimination in an "open lung" approach.

  5. Effect of different breathing aids on ventilation distribution in adults with cystic fibrosis.

    Directory of Open Access Journals (Sweden)

    Markus Wettstein

    Full Text Available BACKGROUND AND OBJECTIVES: We investigated the effect of different breathing aids on ventilation distribution in healthy adults and subjects with cystic fibrosis (CF. METHODS: In 11 healthy adults and 9 adults with CF electrical impedance tomography measurements were performed during spontaneous breathing, continuous positive airway pressure (CPAP and positive expiratory pressure (PEP therapy randomly applied in upright and lateral position. Spatial and temporal ventilation distribution was assessed. RESULTS: The proportion of ventilation directed to the dependent lung significantly increased in lateral position compared to upright in healthy and CF. This effect was enhanced with CPAP but neutralised with PEP, whereas the effect of PEP was larger in the healthy group. Temporal ventilation distribution showed exactly the opposite with homogenisation during CPAP and increased inhomogeneity with PEP. CONCLUSIONS: PEP shows distinct differences to CPAP with respect to its impact on ventilation distribution in healthy adults and CF subjects EIT might be used to individualise respiratory physiotherapy.

  6. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... infant or child manage their lung health, watch parents of children with CF and a respiratory therapist talk about the different techniques they use for airway ... Positive Expiratory Pressure High-Frequency Chest Wall Oscillation (the Vest) Follow ...

  7. The contribution of airway smooth muscle to airway narrowing and airway hyperresponsiveness in disease.

    Science.gov (United States)

    Martin, J G; Duguet, A; Eidelman, D H

    2000-08-01

    Airway hyperresponsiveness (AHR), the exaggerated response to constrictor agonists in asthmatic subjects, is incompletely understood. Changes in either the quantity or properties of airway smooth muscle (ASM) are possible explanations for AHR. Morphometric analyses demonstrate structural changes in asthmatic airways, including subepithelial fibrosis, gland hyperplasia/hypertrophy, neovascularization and an increase in ASM mass. Mathematical modelling of airway narrowing suggests that, of all the changes in structure, the increase in ASM mass is the most probable cause of AHR. An increase in ASM mass in the large airways is more closely associated with a greater likelihood of dying from asthma than increases in ASM mass in other locations within the airway tree. ASM contraction is opposed by the elastic recoil of the lungs and airways, which appears to limit the degree of bronchoconstriction in vivo. The cyclical nature of tidal breathing applies stresses to the airway wall that enhance the bronchodilating influence of the lung tissues on the contracting ASM, in all probability by disrupting cross-bridges. However, the increase in ASM mass in asthma may overcome the limitation resulting from the impedances to ASM shortening imposed by the lung parenchyma and airway wall tissues. Additionally, ASM with the capacity to shorten rapidly may achieve shorter lengths and cause a greater degree of bronchoconstriction when stimulated to contract than slower ASM. Changes in ASM properties are induced by the process of sensitization and allergen-exposure such as enhancement of phospholipase C activity and inositol phosphate turnover, and increases in myosin light chain kinase activity. Whether changes in ASM mass or biochemical/biomechanical properties form the basis for asthma remains to be determined.

  8. Sleep-disordered breathing and mortality: a prospective cohort study.

    OpenAIRE

    Naresh M Punjabi; Brian S Caffo; James L Goodwin; Daniel J Gottlieb; Anne B Newman; George T O'Connor; David M Rapoport; Susan Redline; Helaine E Resnick; John A Robbins; Eyal Shahar; Mark L Unruh; Jonathan M Samet

    2009-01-01

    Editors' Summary Background About 1 in 10 women and 1 in 4 men have a chronic condition called sleep-disordered breathing although most are unaware of their problem. Sleep-disordered breathing, which is commonest in middle-aged and elderly people, is characterized by numerous, brief (10 second or so) interruptions of breathing during sleep. These interruptions, which usually occur when relaxation of the upper airway muscles decreases airflow, lower the level of oxygen in the blood and, as a r...

  9. Oronasal mask may compromise the efficacy of continuous positive airway pressure on OSA treatment: is there evidence for avoiding the oronasal route?

    Science.gov (United States)

    Andrade, Rafaela Garcia Santos; Madeiro, Fernanda; Genta, Pedro Rodrigues; Lorenzi-Filho, Geraldo

    2016-11-01

    Continuous positive airway pressure (CPAP) delivered by nasal mask is the gold standard treatment for obstructive sleep apnea (OSA). However, oral and oronasal masks are also available. We considered experimental evidence and reviewed clinical trials that evaluated the impact of oral and oronasal mask on OSA treatment. One recent study in 18 OSA patients that slept with a customized oronasal mask with two sealed compartments showed that the change of CPAP flow from nasal to oronasal and oral caused upper airway obstruction because of posterior displacement of the tongue demonstrated by nasoendoscopy. Oral masks use a mouthpiece that may stabilize the jaw and the tongue and have shown to be effective. However, oral masks are not widely used in clinical practice. Four out of five observational studies and all five reviewed randomized studies showed a worse performance of oronasal when compared with nasal masks. Oronasal masks were associated with higher residual apnea-hypopnea index, lower adherence, more leaks, and less satisfaction than nasal mask in the majority of the studies. Nasal CPAP must be the first choice to treat OSA. Patients on oronasal mask should be carefully followed. VIDEO ABSTRACT.

  10. Small airways dysfunction and neutrophilic inflammation in bronchial biopsies and BAL in COPD

    NARCIS (Netherlands)

    Lapperre, Thérèse S.; Willems, Luuk N. A.; Timens, Wim; Rabe, Klaus F.; Hiemstra, Pieter S.; Postma, Dirkje S.; Sterk, Peter J.

    2007-01-01

    BACKGROUND: The single-breath N(2) test (sbN(2)-test) is closely related to small airways pathology in resected lung specimens of smokers. We investigated whether uneven ventilation and airway closure are associated with specific markers of airway inflammation as obtained by bronchial biopsies, BAL,

  11. Small airways dysfunction and neutrophilic inflammation in bronchial biopsies and BAL in COPD

    NARCIS (Netherlands)

    Lapperre, Therese S.; Willems, Luuk N. A.; Timens, Wim; Rabe, Klaus F.; Hiemstra, Pieter S.; Postma, Dirkje S.; Sterk, Peter J.

    Background: The single-breath N-2 test (sbN(2)-test) is closely related to small airways pathology in resected lung specimens of smokers. We investigated whether uneven ventilation and airway closure are associated with specific markers of airway inflammation as obtained by bronchial biopsies, BAIL,

  12. Lung function, diagnosis, and treatment of sleep-disordered breathing in children with achondroplasia.

    Science.gov (United States)

    Julliand, Sébastien; Boulé, Michèle; Baujat, Geneviève; Ramirez, Adriana; Couloigner, Vincent; Beydon, Nicole; Zerah, Michel; di Rocco, Federico; Lemerrer, Martine; Cormier-Daire, Valérie; Fauroux, Brigitte

    2012-08-01

    Children with achondroplasia are at risk of sleep-disordered breathing. The aim of the study was to evaluate lung function and sleep-disordered breathing in children with achondroplasia. An interview, clinical examination, lung function tests with blood gases, and a polygraphic sleep study were obtained as part of routine annual evaluation in consecutive children with achondroplasia. We included 30 children (median age 3.0 years, range: 0.4-17.1) over a period of 21 months. Habitual snoring and witnessed apneas were observed in 77% and 33% of the patients, respectively. Prior to the sleep study, 10/29 (34%) patients had undergone upper airway surgery and 5/29 (17%) craniocervical decompression operation. Arterial blood gases were abnormal in two (7%) patients. Sleep findings were abnormal in 28/30 (93%) patients. Eleven (37%) patients had an apnea index≥1 event/hr and 26 (87%) had an apnea-hypopnea index≥5 events/hr. The ≥3% desaturation index was >5/hr in 22 (73%) patients. Sixteen (53%) patients had a minimal pulse oximetry50 mmHg during sleep. As a consequence, the following therapeutic interventions were performed: upper airway surgery in four patients and noninvasive positive pressure ventilation (NPPV) in five other patients, resulting in an improvement in sleep studies in all nine patients. Systematic sleep studies are recommended in children with achondroplasia because of the high prevalence of sleep-disordered breathing. Upper airway surgery and NPPV are effective treatments of sleep-disordered breathing. Copyright © 2012 Wiley Periodicals, Inc.

  13. Corneal Neovascularization with Associated Lipid Keratopathy in a Patient with Obstructive Sleep Apnea-Hypopnea Syndrome Using a Continuous Positive Airway Pressure Machine

    Directory of Open Access Journals (Sweden)

    Konstantinos Oikonomakis

    2017-08-01

    Full Text Available Objective: To report a case of corneal neovascularization with secondary lipid keratopathy in a patient treated with continuous positive airway pressure (CPAP for obstructive sleep apnea-hypopnea syndrome (OSAHS. Case Report: A 49-year-old male had been diagnosed with obstructive sleep apnea syndrome 10 years ago and has been treated with the application of a CPAP machine during night sleep ever since. For the past year, the patient had been complaining for ocular irritation and excessive tearing of the left eye on awakening. Slit-lamp biomicroscopy revealed the presence of neovascularization and lipid exudation in the inferior third of the cornea of the left eye. Ocular patching during night sleep resulted in recession of the reported symptoms and shrinkage of the neovascularization, while the area of lipid exudation ceased to enlarge. Conclusion: To the best of our knowledge, this is the first report of corneal neovascularization in a patient using a CPAP machine for OSAHS.

  14. Corneal Neovascularization with Associated Lipid Keratopathy in a Patient with Obstructive Sleep Apnea-Hypopnea Syndrome Using a Continuous Positive Airway Pressure Machine.

    Science.gov (United States)

    Oikonomakis, Konstantinos; Petrelli, Myrsini; Andreanos, Konstantinos; Mouchtouris, Andreas; Petrou, Petros; Georgalas, Ilias; Papaconstantinou, Dimitrios; Kymionis, George

    2017-01-01

    To report a case of corneal neovascularization with secondary lipid keratopathy in a patient treated with continuous positive airway pressure (CPAP) for obstructive sleep apnea-hypopnea syndrome (OSAHS). A 49-year-old male had been diagnosed with obstructive sleep apnea syndrome 10 years ago and has been treated with the application of a CPAP machine during night sleep ever since. For the past year, the patient had been complaining for ocular irritation and excessive tearing of the left eye on awakening. Slit-lamp biomicroscopy revealed the presence of neovascularization and lipid exudation in the inferior third of the cornea of the left eye. Ocular patching during night sleep resulted in recession of the reported symptoms and shrinkage of the neovascularization, while the area of lipid exudation ceased to enlarge. To the best of our knowledge, this is the first report of corneal neovascularization in a patient using a CPAP machine for OSAHS.

  15. Effect of Continuous Positive Airway Pressure Ventilation on Platelet-activating Factor and Blood Coagulation Function in Patients with Obstructive Sleep Apnea-hypopnea Syndrome

    International Nuclear Information System (INIS)

    Chen Xiangkun; Sheng Chunyong

    2010-01-01

    To investigate the effect of continuous positive airway pressure ventilation (CPAP) on platelet-activating factor (PAF) expression and blood coagulation function in patients with obstructive sleep apnea-hypopnea syndrome (OSAS), the blood sample of 40 patients with OSAS were taken before treatment and on the day 30 after treatment respectively. PAF, thromboxane B 2 (TXB2), prothrombin time (PT), activated partial thromboplastin time (APTT) and fibrin(FIB) in patients and 37 health controls were detected. The results showed that PAF, TXB2, FIB in OSAS patients before treatment were significantly higher than those of after treatment and control group (P 0.05). There were abnormal expression of PAF and hypercoagulability in OSAS patients. CPAP could effectively decrease the expression of PAF, TXB 2 and could also correct dysfunction of blood coagulation. It had certain effect in lightening the clinical symptoms in OSAS patients. (authors)

  16. Development and Implementation of a Training-of-Trainers Program for Continuous Positive Airway Pressure in Neonatal and Pediatric Patients in Five Low- and Middle-Income Countries.

    Science.gov (United States)

    Wilson, Patrick T; Benckert, Megan M; Moresky, Rachel T; Morris, Marilyn C

    2017-10-01

    We describe a pragmatic training-of-trainers program for the use of continuous positive airway pressure (CPAP) for neonatal and pediatric patients. The program is designed for medical professionals working in low- and middle-income countries and involves 2 days of in-class training followed by 1 day of in-service training. The program was created after training in Cambodia, Ghana, Honduras, Kenya and Rwanda and addresses the issues of resource availability, cultural context and local buy-in and partnership in low- and middle-income countries. We hope others will use the training program to increase knowledge and use of CPAP with the ultimate goal of improving neonatal and pediatric survival globally. © The Author [2017]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. 46 CFR 197.456 - Breathing supply hoses.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Breathing supply hoses. 197.456 Section 197.456 Shipping....456 Breathing supply hoses. (a) The diving supervisor shall insure that— (1) Each breathing supply....5 times its maximum working pressure; (2) Each breathing supply hose assembly, prior to being placed...

  18. Fluid structure interaction simulations of the upper airway in obstructive sleep apnea patients before and after maxillomandibular advancement surgery.

    Science.gov (United States)

    Chang, Kwang K; Kim, Ki Beom; McQuilling, Mark W; Movahed, Reza

    2018-06-01

    The purpose of this study was to analyze pharyngeal airflow using both computational fluid dynamics (CFD) and fluid structure interactions (FSI) in obstructive sleep apnea patients before and after maxillomandibular advancement (MMA) surgery. The airflow characteristics before and after surgery were compared with both CFD and FSI. In addition, the presurgery and postsurgery deformations of the airway were evaluated using FSI. Digitized pharyngeal airway models of 2 obstructive sleep apnea patients were generated from cone-beam computed tomography scans before and after MMA surgery. CFD and FSI were used to evaluate the pharyngeal airflow at a maximum inspiration rate of 166 ml per second. Standard steady-state numeric formulations were used for airflow simulations. Airway volume increased, pressure drop decreased, maximum airflow velocity decreased, and airway resistance dropped for both patients after the MMA surgery. These findings occurred in both the CFD and FSI simulations. The FSI simulations showed an area of marked airway deformation in both patients before surgery, but this deformation was negligible after surgery for both patients. Both CFD and FSI simulations produced airflow results that indicated less effort was needed to breathe after MMA surgery. The FSI simulations demonstrated a substantial decrease in airway deformation after surgery. These beneficial changes positively correlated with the large improvements in polysomnography outcomes after MMA surgery. Copyright © 2018 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  19. Oral appliance therapy versus nasal continuous positive airway pressure in obstructive sleep apnoea syndrome: a randomised, placebo-controlled trial on self-reported symptoms of common sleep disorders and sleep-related problems

    NARCIS (Netherlands)

    Nikolopoulou, M.; Byraki, A.; Ahlberg, J.; Heymans, M. W.; Hamburger, H. L.; de Lange, J.; Lobbezoo, F.; Aarab, G.

    2017-01-01

    Obstructive sleep apnoea syndrome (OSAS) is associated with several sleep disorders and sleep-related problems. Therefore, the aim of this study was to compare the effects of a mandibular advancement device (MAD) with those of nasal continuous positive airway pressure (nCPAP) on self-reported

  20. Lung sound analysis helps localize airway inflammation in patients with bronchial asthma

    Directory of Open Access Journals (Sweden)

    Shimoda T

    2017-03-01

    Full Text Available Terufumi Shimoda,1 Yasushi Obase,2 Yukio Nagasaka,3 Hiroshi Nakano,1 Akiko Ishimatsu,1 Reiko Kishikawa,1 Tomoaki Iwanaga1 1Clinical Research Center, Fukuoka National Hospital, Fukuoka, 2Second Department of Internal Medicine, School of Medicine, Nagasaki University, Nagasaki, 3Kyoto Respiratory Center, Otowa Hospital, Kyoto, Japan Purpose: Airway inflammation can be detected by lung sound analysis (LSA at a single point in the posterior lower lung field. We performed LSA at 7 points to examine whether the technique could identify the location of airway inflammation in patients with asthma. Patients and methods: Breath sounds were recorded at 7 points on the body surface of 22 asthmatic subjects. Inspiration sound pressure level (ISPL, expiration sound pressure level (ESPL, and the expiration-to-inspiration sound pressure ratio (E/I were calculated in 6 frequency bands. The data were analyzed for potential correlation with spirometry, airway hyperresponsiveness (PC20, and fractional exhaled nitric oxide (FeNO. Results: The E/I data in the frequency range of 100–400 Hz (E/I low frequency [LF], E/I mid frequency [MF] were better correlated with the spirometry, PC20, and FeNO values than were the ISPL or ESPL data. The left anterior chest and left posterior lower recording positions were associated with the best correlations (forced expiratory volume in 1 second/forced vital capacity: r=–0.55 and r=–0.58; logPC20: r=–0.46 and r=–0.45; and FeNO: r=0.42 and r=0.46, respectively. The majority of asthmatic subjects with FeNO ≥70 ppb exhibited high E/I MF levels in all lung fields (excluding the trachea and V50%pred <80%, suggesting inflammation throughout the airway. Asthmatic subjects with FeNO <70 ppb showed high or low E/I MF levels depending on the recording position, indicating uneven airway inflammation. Conclusion: E/I LF and E/I MF are more useful LSA parameters for evaluating airway inflammation in bronchial asthma; 7-point lung

  1. Airway stents

    Science.gov (United States)

    Keyes, Colleen

    2018-01-01

    Stents and tubes to maintain the patency of the airways are commonly used for malignant obstruction and are occasionally employed in benign disease. Malignant airway obstruction usually results from direct involvement of bronchogenic carcinoma, or by extension of carcinomas occurring in the esophagus or the thyroid. External compression from lymph nodes or metastatic disease from other organs can also cause central airway obstruction. Most malignant airway lesions are surgically inoperable due to advanced disease stage and require multimodality palliation, including stent placement. As with any other medical device, stents have significantly evolved over the last 50 years and deserve an in-depth understanding of their true capabilities and complications. Not every silicone stent is created equal and the same holds for metallic stents. Herein, we present an overview of the topic as well as some of the more practical and controversial issues surrounding airway stents. We also try to dispel the myths surrounding stent removal and their supposed use only in central airways. At the end, we come to the long-held conclusion that stents should not be used as first line treatment of choice, but after ruling out the possibility of curative surgical resection or repair. PMID:29707506

  2. [Comparison of efficacy between continuous positive airway pressure and renal artery sympathetic denervation by radiofrequency ablation in obstructive sleep apnea syndrome patients with hypertension].

    Science.gov (United States)

    Zhao, Meng-meng; Tan, Xue-xue; Ding, Ning; Zhang, Xi-long

    2013-04-23

    To compare the efficacy of renal arterial sympathetic denervation (RSD) and continuous positive airway pressure (CPAP) in patients with coexisting moderate-to-severe obstructive sleep apnea syndrome (OSAS) and hypertension. Retrospective analysis was conducted for patients with coexisting moderate to severe OSAS and hypertension for the efficacy of RSD (RSD group, n = 15) and CPAP (CPAP group, n = 16). Comparison was made for polysomnographic parameters and 24 hours ambulatory blood pressure (Bp) between two groups. There was no significant difference in age, gender, body mass index, nocturnal apnea hypopnea index (AHI), mean and minimal pulse oxygen saturation (mean SpO2 and mini SpO2) between two groups. Compared with those at pre-treatment, the following changes were observed at Day 30 post-treatment: in RSD group, the nocturnal AHI and T90 statistically decreased (27 ± 14 vs 32 ± 12, 8.7% ± 7.8% vs 13.8% ± 13.1%, all P 0.05); in CPAP group during treatment, nocturnal AHI and the ratio of duration SpO2 hypertension, both RSD and CPAP may improve sleep respiratory parameters and blood pressure to varying degrees. There is a more significant improvement of nocturnal AHI and SpO2 in CPAP group and more lower MSBp in RSD group.

  3. Medical Issues: Breathing

    Science.gov (United States)

    ... Information Packets Equipment Pool Living With SMA Medical Issues Palliative Breathing Orthopedics Nutrition Equipment Daily Life At ... curesma.org > support & care > living with sma > medical issues > breathing Breathing Breathing problems are the most common ...

  4. The Influence of Fundamental Frequency and Sound Pressure Level Range on Breathing Patterns in Female Classical Singing

    Science.gov (United States)

    Collyer, Sally; Thorpe, C. William; Callaghan, Jean; Davis, Pamela J.

    2008-01-01

    Purpose: This study investigated the influence of fundamental frequency (F0) and sound pressure level (SPL) range on respiratory behavior in classical singing. Method: Five trained female singers performed an 8-s messa di voce (a crescendo and decrescendo on one F0) across their musical F0 range. Lung volume (LV) change was estimated, and…

  5. A pilot study to examine the effect of the Tulip oropharyngeal airway on ventilation immediately after mask ventilation following the induction of anaesthesia.

    Science.gov (United States)

    Robinson, P N; Shaikh, A; Sabir, N M; Vaughan, D J A; Kynoch, M; Hasan, M

    2014-07-01

    The Tulip airway is an adult, disposable, single-sized oropharyngeal airway, that is connectable to an anaesthetic circuit. After a standardised induction of anaesthesia in 75 patients, the ease of insertion, intracuff pressure and intracuff volume were measured, as were the end-tidal carbon dioxide levels, airway pressures and tidal volumes over three breaths. Successful first-time insertion was achieved in 72 patients (96%, CI 88.8-99.2%) and after two attempts in 74 patients (99%, CI 92.8-100%). There was outright failure only in one patient. In 60 patients (80%, CI 72.2-90.4%), the Tulip airway provided a patent airway without additional manoeuvres, but in 14 patients, jaw thrust or head extension was necessary for airway patency. The main need for these adjuncts appeared to be an initial under-inflation of the cuff. These promising results are consistent with recent manikin studies using this device. © 2014 The Association of Anaesthetists of Great Britain and Ireland.

  6. Determination of viscous pressure losssand resistance upstream from the choke point from breathing gases of different physical properties

    DEFF Research Database (Denmark)

    Pedersen, O.F.

    2007-01-01

    /mair)2- a  (JAP 48:313-319,1980), where r is gas  density and  m  is viscosity. a is an exponent  = 1 for laminar flow and  2 for turbulent flow MATERIAL AND METHOD: Nine healthy males , mean age (sd) = 32 (10) years examined in a pressure corrected flow body-plethysmograph, with measurement of maximum...

  7. Effect of oxygenation on breath-by-breath response of the genioglossus muscle during occlusion.

    Science.gov (United States)

    Gauda, E B; Carroll, J L; McColley, S; Smith, P L

    1991-10-01

    We investigated the effect of different levels of O2 tension (hypoxia, normoxia, and hyperoxia) on the breath-by-breath onset and peak electromyographic (EMG) activity of the genioglossus (GG) muscle during a five-breath end-expiratory tracheal occlusion of 20- to 30-s duration. GG and diaphragmatic (DIA) EMG activity were measured with needle electrodes in eight anesthetized tracheotomized adult cats. In response to occlusion, the increase in the number of animals with GG EMG activity was different during hypoxia, normoxia, and hyperoxia (P = 0.003, Friedman). During hypoxia, eight of eight of the animals had GG EMG activity by the third occluded effort. In contrast, during normoxia, only four of eight and, during hyperoxia, only three of eight animals had GG EMG activity throughout the entire five-breath occlusion. Similarly, at release of the occlusion, more animals had persistent GG EMG activity on the postocclusion breaths during hypoxia than during normoxia or hyperoxia. Breath-by-breath augmentation of peak amplitude of the GG and DIA EMGs on each occluded effort was accentuated during hypoxia (P less than 0.01) and abolished during hyperoxia (P = 0.10). These results suggest that hypoxemia is a major determinant of the rapidity of onset, magnitude, and sustained activity of upper airway muscles during airway occlusion.

  8. Minimum concentrations of NO/sub 2/ causing acute effects on the respiratory gas exchange and airway-resistance in patients with chronic bronchitis

    Energy Technology Data Exchange (ETDEWEB)

    von Nieding, G; Wagner, M; Krekeler, H; Smidt, U; Muysers, K

    1971-01-01

    Nitrogen dioxide-air mixtures containing 0.5 to 5.0 ppM NO/sub 2/ were inhaled by 88 patients with chronic bronchitis over a 15-minute period for a total of 30 breaths during studies investigating the effects of the gas on airway resistance and respiratory gas exchange. End-expiratory oxygen pressures remained nearly constant during inhalation of 4 or 5 ppM NO/sub 2/, though significant decreases in arterial oxygen pressure accompanied by increases in end-expiratory-arterial oxygen pressure difference occurred. Inhalation of 2 ppM NO/sub 2/ did not decrease arterial oxygen pressure. Airway resistances increased significantly down to 1.5 ppM NO/sub 2/ concentrations. Lower concentrations caused no significant effects.

  9. Stroke and sleep-disordered breathing: A relationship under construction.

    Science.gov (United States)

    Parra, Olga; Arboix, Adrià

    2016-02-16

    The association between sleep-disordered breathing (SDB) and cardiovascular risk has been the focus of attention in recent years. Sleep disorders are emerging risk factors for cardiovascular disease and have been related to the whole spectrum of stroke, including transient ischemic attack, ischemic cerebral infarction and intracerebral haemorrhage. It has been shown that lacunar stroke or lacunar infarctions affecting the internal capsule or the protuberance are associated with a higher frequency of SDB. Acute stroke patients with associated SDB have a worse prognosis and a higher mortality as compared to patients with first-ever stroke without SDB. Preliminary studies provide evidence of the usefulness of treatment with continuous positive airway pressure when SDB is present in stroke patients.

  10. Curative effect of continuous positive airway pressure on treatment of patients with obstructive sleep apnea hypopnea syndrome and hypertension: A Meta-analysis

    Directory of Open Access Journals (Sweden)

    Bi-fang MIAO

    2016-12-01

    Full Text Available Objective  To systematically evaluate the curative effect of continuous positive airway pressure (CPAP on treatment of patients with obstructive sleep apnea hypopnea syndrome (OSAHS and hypertension. Methods  The data were retrieved of randomized controlled trials (RCTs about the curative effect of CPAP on treatment of patients with OSAHS and hypertension from PubMed, Cochrane Library, CNKI, VIP, CBM and WanFang database from inception to Oct. 2015. Literature screening, data extraction and risk bias assessment were performed by two independent reviewers, and meta-analysis was then carried out by using RevMan 5.3 software. Results  A total of 16 RCTs involving 2101 patients were included. Meta-analysis revealed that, compared with the antihypertensive drug therapy alone, CPAP plus antihypertensive drug therapy significantly reduced the daytime systolic pressure [MD=–12.60, 95%CI(–17.68 to –7.52, P<0.00001], nighttime systolic pressure [MD=–21.90, 95%CI(–25.94 to –17.86, P<0.00001] and nighttime diastolic pressure [MD=–11.90, 95%CI(–15.44 to –8.36, P<0.00001], while created no significant difference in daytime diastolic pressure, 24-h mean systolic pressure and 24-h mean diastolic pressure in a following-up less than 12 weeks. Whereas in the following-up no less than 12 weeks, compared with the antihypertensive drug therapy alone, CPAP plus antihypertensive drug therapy significantly reduced the 24-h mean systolic pressure [MD=–7.88, 95%CI(–12.09 to –3.66, P=0.00002], 24-h mean diastolic pressure [MD=–5.14, 95%CI(–6.00 to –4.28, P<0.00001], daytime systolic pressure [MD=–5.89, 95%CI(–8.79 to –2.98, P<0.0001], daytime diastolic pressure [MD=–4.34, 95%CI(–6.32 to –2.36, P<0.0001]; nighttime systolic pressure [MD=–7.06, 95%CI(–11.12 to –2.99, P=0.0007] and nighttime diastolic pressure [MD=–4.49, 95%CI (–7.39 to –1.58, P=0.006]. Conclusions  The current evidences suggest that on the basis

  11. [Study of setting of ventilator volume tidal and airway pressure alarm threshold with continuous extra-sternum heart compression in cardiopulmonary resuscitation].

    Science.gov (United States)

    Luo, Jian-yu; Wang, Xiao-yuan; Cai, Tian-bin; Jiang, Wen-fang

    2013-02-01

    To investigate the setting of ventilator volume tidal (VT) and airway pressure alarm threshold during cardiopulmonary resuscitation (CPR) by continuous extra-sternum heart compression. Forty cases with respiration and cardiac arrest in the department of critical care medicine were randomly divided into low VT ventilation group and conventional VT group. Both groups were given the volume control mode. In the low VT ventilation group, VT was set on 6 - 7 ml/kg, and high pressure alarm threshold was adjusted to 60 cm H2O by the conventional 40 cm H2O during CPR. In the conventional VT group, VT and high pressure alarm threshold were set at 8 - 12 ml/kg and 40 cm H2O, respectively. Real-time actual VT, peak inspiratory pressure (PIP), and arterial blood gas test, blood lactic acid at 10 minutes and 30 minutes after CPR were observed. At 10 minutes after CPR, in the low VT ventilation group, arterial blood pH, arterial partial pressure of oxygen (PaO2), arterial partial pressure of carbon dioxide (PaCO2), HCO3(-), arterial oxygen saturation (SaO2) and blood lactic acid were better as compared with those in the conventional VT ventilation group (pH: 7.21±0.09 vs. 7.13±0.07, PaO2: 45.35±5.92 mm Hg vs. 40.70±4.70 mm Hg, PaCO2: 57.10±7.59 mm Hg vs. 61.60±5.47 mm Hg, HCO3(-): 18.50±3.50 mmol/L vs. 14.75±2.65 mmol/L, SaO2: 0.796±0.069 vs. 0.699±0.066, blood lactic acid: 7.07±1.60 mmol/L vs. 8.13±1.56 mmol/L, all P<0.05). The success rate of resuscitation in the low VT ventilation group was higher than that of the conventional VT ventilation group (45% vs. 15%, P<0.05), and PIP (cm H2O) of low VT ventilation group was lower than that of the conventional VT group (37.25±7.99 cm H2O vs. 42.70±7.40 cm H2O, P<0.05). In all the patients in both groups barotrauma did not occur. The strategy of low ventilator VT (6 - 7 ml/kg) with appropriate elevation of airway pressure alarm threshold was better than that of conventional ventilation setting, with no increase in

  12. Effect of airway acidosis and alkalosis on airway vascular smooth muscle responsiveness to albuterol.

    Science.gov (United States)

    Cancado, Jose E; Mendes, Eliana S; Arana, Johana; Horvath, Gabor; Monzon, Maria E; Salathe, Matthias; Wanner, Adam

    2015-04-02

    In vitro and animal experiments have shown that the transport and signaling of β2-adrenergic agonists are pH-sensitive. Inhaled albuterol, a hydrophilic β2-adrenergic agonist, is widely used for the treatment of obstructive airway diseases. Acute exacerbations of obstructive airway diseases can be associated with changes in ventilation leading to either respiratory acidosis or alkalosis thereby affecting albuterol responsiveness in the airway. The purpose of this study was to determine if airway pH has an effect on albuterol-induced vasodilation in the airway. Ten healthy volunteers performed the following respiratory maneuvers: quiet breathing, hypocapnic hyperventilation, hypercapnic hyperventilation, and eucapnic hyperventilation (to dissociate the effect of pH from the effect of ventilation). During these breathing maneuvers, exhaled breath condensate (EBC) pH and airway blood flow response to inhaled albuterol (ΔQ̇aw) were assessed. Mean ± SE EBC pH (units) and ΔQ̇aw (μl.min(-1).mL(-1)) were 6.4 ± 0.1 and 16.8 ± 1.9 during quiet breathing, 6.3 ± 0.1 and 14.5 ± 2.4 during eucapnic hyperventilation, 6.6 ± 0.2 and -0.2 ± 1.8 during hypocapnic hyperventilation (p = 0.02 and <0.01 vs. quiet breathing), and 5.9 ± 0.1 and 2.0 ± 1.5 during hypercapnic hyperventilation (p = 0.02 and <0.02 vs quiet breathing). Albuterol responsiveness in the airway as assessed by ΔQ̇aw is pH sensitive. The breathing maneuver associated with decreased and increased EBC pH both resulted in a decreased responsiveness independent of the level of ventilation. These findings suggest an attenuated response to hydrophilic β2-adrenergic agonists during airway disease exacerbations associated with changes in pH. Registered at clinicaltrials.gov: NCT01216748 .

  13. Control of upper airway muscle activity in younger versus older men during sleep onset

    Science.gov (United States)

    Fogel, Robert B; White, David P; Pierce, Robert J; Malhotra, Atul; Edwards, Jill K; Dunai, Judy; Kleverlaan, Darci; Trinder, John

    2003-01-01

    Pharyngeal dilator muscles are clearly important in the pathophysiology of obstructive sleep apnoea syndrome (OSA). We have previously shown that the activity of both the genioglossus (GGEMG) and tensor palatini (TPEMG) are decreased at sleep onset, and that this decrement in muscle activity is greater in the apnoea patient than in healthy controls. We have also previously shown this decrement to be greater in older men when compared with younger ones. In order to explore the mechanisms responsible for this decrement in muscle activity nasal continuous positive airway pressure (CPAP) was applied to reduce negative pressure mediated muscle activation. We then investigated the effect of sleep onset (transition from predominantly α to predominantly θ EEG activity) on ventilation, upper airway muscle activation and upper airway resistance (UAR) in middle-aged and younger healthy men. We found that both GGEMG and TPEMG were reduced by the application of nasal CPAP during wakefulness, but that CPAP did not alter the decrement in activity in either muscle seen in the first two breaths following an α to θ transition. However, CPAP prevented both the rise in UAR at sleep onset that occurred on the control night, and the recruitment in GGEMG seen in the third to fifth breaths following the α to θ transition. Further, GGEMG was higher in the middle-aged men than in the younger men during wakefulness and was decreased more in the middle-aged men with the application of nasal CPAP. No differences were seen in TPEMG between the two age groups. These data suggest that the initial sleep onset reduction in upper airway muscle activity is due to loss of a ‘wakefulness’ stimulus, rather than to loss of responsiveness to negative pressure. In addition, it suggests that in older men, higher wakeful muscle activity is due to an anatomically more collapsible upper airway with more negative pressure driven muscle activation. Sleep onset per se does not appear to have a greater

  14. Comparison Study of Airway Reactivity Outcomes due to a Pharmacologic Challenge Test: Impulse Oscillometry versus Least Mean Squared Analysis Techniques

    Directory of Open Access Journals (Sweden)

    Elena Rodriguez

    2013-01-01

    Full Text Available The technique of measuring transpulmonary pressure and respiratory airflow with manometry and pneumotachography using the least mean squared analysis (LMS has been used broadly in both preclinical and clinical settings for the evaluation of neonatal respiratory function during tidal volume breathing for lung tissue and airway frictional mechanical properties measurements. Whereas the technique of measuring respiratory function using the impulse oscillation technique (IOS involves the assessment of the relationship between pressure and flow using an impulse signal with a range of frequencies, requires less cooperation and provides more information on total respiratory system resistance (chest wall, lung tissue, and airways. The present study represents a preclinical animal study to determine whether these respiratory function techniques (LMS and IOS are comparable in detecting changes in respiratory resistance derived from a direct pharmacological challenge.

  15. Effects of Heated Humidification and Topical Steroids on Compliance, Nasal Symptoms, and Quality of Life in Patients with Obstructive Sleep Apnea Syndrome Using Nasal Continuous Positive Airway Pressure

    Science.gov (United States)

    Ryan, Silke; Doherty, Liam S.; Nolan, Geraldine M.; McNicholas, Walter T.

    2009-01-01

    Background: Nasal side effects are common in patients with obstructive sleep apnea syndrome (OSAS) starting on nasal continuous positive airway pressure (CPAP) therapy. We tested the hypothesis that heated humidification or nasal topical steroids improve compliance, nasal side effects and quality of life in this patient group. Methods: 125 patients with the established diagnosis of OSAS (apnea/hypopnea index ≥ 10/h), who tolerated CPAP via a nasal mask, and who had a successful CPAP titration were randomized to 4 weeks of dry CPAP, humidified CPAP or CPAP with additional topical nasal steroid application (fluticasone, GlaxoWellcome). Groups were similar in all demographic variables and in frequency of nasal symptoms at baseline. Outcome measures were objective compliance, quality of life (short form 36), subjective sleepiness (Epworth Sleepiness Scale score) and nasal symptoms such as runny, dry or blocked nose, sneezing and headaches; all variables assessed using a validated questionnaire and by direct interview. Results: There was no difference in compliance between groups after 4 weeks (dry: 5.21 ± 1.66 h/night, fluticasone: 5.66 ± 1.68, humidifier: 5.21 ± 1.84; p = 0.444). Quality of life and subjective sleepiness improved in all groups, but there were no differences in the extent of improvement. Nasal Symptoms were less frequently reported in the humidifier group (28%) than in the remaining groups (dry: 70%, fluticasone: 53%, p = 0.002). However, the addition of fluticasone resulted in increased frequency of sneezing. Conclusion: The addition of a humidifier, but not nasal steroids decreases the frequency of nasal symptoms in unselected OSAS patients initiating CPAP therapy; however compliance and quality of life remain unaltered. Citation: Ryan S; Doherty LS; Nolan GM; McNicholas WT. Effects of heated humidification and topical steroids on compliance, nasal symptoms, and quality of life in patients with obstructive sleep apnea syndrome using nasal

  16. Comparisons of different mean airway pressure settings during high-frequency oscillation in inflammatory response to oleic acid-induced lung injury in rabbits

    Directory of Open Access Journals (Sweden)

    Koichi Ono

    2009-03-01

    Full Text Available Koichi Ono1, Tomonobu Koizumi2, Rikimaru Nakagawa1, Sumiko Yoshikawa2, Tetsutarou Otagiri11Department of Anesthesiology and Resuscitation; 2First Department of Internal Medicine, Shinshu University School of Medicine, Matsumoto, JapanPurpose: The present study was designed to examine effects of different mean airway pressure (MAP settings during high-frequency oscillation (HFO on oxygenation and inflammatory responses to acute lung injury (ALI in rabbits.Methods: Anesthetized rabbits were mechanically ventilated with a conventional mechanical ventilation (CMV mode (tidal volume 6 ml/kg, inspired oxygen fraction [FIo2] of 1.0, respiratory rate [RR] of 30/min, positive end-expiratory pressure [PEEP] of 5 cmH2O. ALI was induced by intravenous administration of oleic acid (0.08 ml/kg and the animals were randomly allocated to the following three experimental groups; animals (n = 6 ventilated using the same mode of CMV, or animals ventilated with standard MAP (MAP 10 cmH2O, n = 7, and high MAP (15 cmH2O, n = 6 settings of HFO (Hz 15. The MAP settings were calculated by the inflation limb of the pressure-volume curve during CMV.Results: HFO with a high MAP setting significantly improved the deteriorated oxygenation during oleic acid-induced ALI and reduced wet/dry ratios, neutrophil counts and interleukin-8 concentration in bronchoalveolar lavage fluid, compared to those parameters in CMV and standard MAP-HFO.Conclusions: These findings suggest that only high MAP setting during HFO could contribute to decreased lung inflammation as well as improved oxygenation during the development of ALI.Keywords: lung protective ventilation, open lung ventilation, IL-8, neutrophil

  17. New frontiers in CT imaging of airway disease

    International Nuclear Information System (INIS)

    Grenier, Philippe A.; Beigelman-Aubry, Catherine; Fetita, Catalin; Preteux, Francoise; Brauner, Michel W.; Lenoir, Stephane

    2002-01-01

    Combining helical volumetric CT acquisition and thin-slice thickness during breath hold provides an accurate assessment of both focal and diffuse airway diseases. With multiple detector rows, compared with single-slice helical CT, multislice CT can cover a greater volume, during a simple breath hold, and with better longitudinal and in-plane spatial resolution and improved temporal resolution. The result in data set allows the generation of superior multiplanar and 3D images of the airways, including those obtained from techniques developed specifically for airway imaging, such as virtual bronchography and virtual bronchoscopy. Complementary CT evaluation at suspended or continuous full expiration is mandatory to detect air trapping that is a key finding for depicting an obstruction on the small airways. Indications for CT evaluation of the airways include: (a) detection of endobronchial lesions in patients with an unexplained hemoptysis; (b) evaluation of extent of tracheobronchial stenosis for planning treatment and follow-up; (c) detection of congenital airway anomalies revealed by hemoptysis or recurrent infection; (d) detection of postinfectious or postoperative airway fistula or dehiscence; and (e) diagnosis and assessment of extent of bronchiectasis and small airway disease. Improvement in image analysis technique and the use of spirometrically control of lung volume acquisition have made possible accurate and reproducible quantitative assessment of airway wall and lumen areas and lung density. This contributes to better insights in physiopathology of obstructive lung disease, particularly in chronic obstructive pulmonary disease and asthma. (orig.)

  18. Medication effects on sleep and breathing.

    Science.gov (United States)

    Seda, Gilbert; Tsai, Sheila; Lee-Chiong, Teofilo

    2014-09-01

    Sleep respiration is regulated by circadian, endocrine, mechanical and chemical factors, and characterized by diminished ventilatory drive and changes in Pao2 and Paco2 thresholds. Hypoxemia and hypercapnia are more pronounced during rapid eye movement. Breathing is influenced by sleep stage and airway muscle tone. Patient factors include medical comorbidities and body habitus. Medications partially improve obstructive sleep apnea and stabilize periodic breathing at altitude. Potential adverse consequences of medications include precipitation or worsening of disorders. Risk factors for adverse medication effects include aging, medical disorders, and use of multiple medications that affect respiration. Published by Elsevier Inc.

  19. The effect of positive and negative message framing on short term continuous positive airway pressure compliance in patients with obstructive sleep apnea.

    Science.gov (United States)

    Pengo, Martino F; Czaban, Marcin; Berry, Marc P; Nirmalan, Prajeshan; Brown, Richard; Birdseye, Adam; Woroszyl, Asia; Chapman, Julia; Kent, Brian D; Hart, Nicholas; Rossi, Gian Paolo; Steier, Joerg

    2018-01-01

    Continuous positive airway pressure (CPAP), the best available treatment for obstructive sleep apnea (OSA), requires long-term compliance to be effective. Behavioral interventions may be used to improve adherence to CPAP. We aimed to investigate whether positive or negative message framing impacts on CPAP compliance in patients with OSA, when compared to standard care. Consenting patients with confirmed OSA were randomly allocated to receive along with their CPAP either positively or negatively framed messages (Pos; Neg), or standard care (Con). Standardized motivational messages were read out to patients during an initial teaching session and through weekly telephone calls. Patients' compliance data were reviewed 2 and 6 weeks following CPAP initiation. We randomized 112 patients to groups that were matched for age, BMI, and OSA severity. The positively framed group (Pos) showed greater CPAP usage after 2 weeks (total use 53.7±31.4 hours) as compared to the negatively framed and the control group (35.6±27.4 and 40.8±33.5 hours, Pframed groups (Pos n=5; Neg n=8; Con n=11; Pframed messages can improve CPAP adherence in patients with OSA in the short-term; however, strategies for implementing its long-term use need to be developed.

  20. Adolescents with obstructive sleep apnea adhere poorly to positive airway pressure (PAP, but PAP users show improved attention and school performance.

    Directory of Open Access Journals (Sweden)

    Dean W Beebe

    2011-03-01

    Full Text Available Obstructive Sleep Apnea (OSA is associated with medical and neurobehavioral morbidity across the lifespan. Positive airway pressure (PAP treatment has demonstrated efficacy in treating OSA and has been shown to improve daytime functioning in adults, but treatment adherence can be problematic. There are nearly no published studies examining functional outcomes such as academic functioning in adolescents treated with PAP. This study was conducted as an initial step towards determining whether PAP treatment improves daytime functioning among adolescents with OSA.Self-reported academic grades, self- and parent-reported academic quality of life, and objectively-measured attention were assessed before and after PAP was clinically initiated in a sample of 13 obese adolescents with OSA, as well as 15 untreated obese Controls without OSA. Based on adherence data, the treated group was divided into PAP Users (n = 6 and Non-Adherent participants (n = 7.Though demographically similar, the three groups significantly differed in how their academic performance and attention scores changed from baseline to follow-up. Non-Adherent participants showed worsening functioning over time, while PAP Users showed stable or improved functioning, similar to controls.Although many adolescents prescribed PAP for OSA are non-adherent to the treatment, those who adhere to treatment can display improved attention and academic functioning.

  1. Effect of continuous positive airway pressure treatment on short-term memory performance over 24 h of sustained wakefulness in patients with obstructive sleep apnea-hypopnea syndrome.

    Science.gov (United States)

    Grenèche, Jérôme; Krieger, Jean; Bertrand, Frédéric; Erhardt, Christine; Maumy, Myriam; Tassi, Patricia

    2013-10-01

    Few studies have examined the impact of continuous positive airway pressure (CPAP) therapy on short-term memory (STM) over sustained wakefulness in patients with obstructive sleep apnea-hypopnea syndrome (OSAHS). We have investigated if impaired STM can be reversed by CPAP treatment in a 24-h sustained wakefulness paradigm. Our follow-up study was conducted with repeated-memory tasks within 12 OSAHS patients and 10 healthy controls who underwent three 32-h sessions, one before CPAP (T0) and the second (T3) and the third (T6), after 3 and 6 months of treatment, respectively, for OSAHS patients. Each session included one night of sleep followed by 24h of sustained wakefulness, during which both groups performed STM tasks including both digit span (DS) and Sternberg tasks. Untreated OSAHS patients had no deficit in the forward DS task measuring immediate memory but were impaired in STM, especially working memory assessed by the complex Sternberg task and the backward DS. However, only performance in the latter was improved after 6 months of CPAP treatment. Because the high level of memory scanning required high speed in information processing, persistent impairment on the complex Sternberg task may be attributable to working memory slowing, possibly enhanced by sustained wakefulness. Crown Copyright © 2013. Published by Elsevier B.V. All rights reserved.

  2. Efficacy of Bilevel-auto Treatment in Patients with Obstructive Sleep Apnea Not Responsive to or Intolerant of Continuous Positive Airway Pressure Ventilation.

    Science.gov (United States)

    Carlucci, Annalisa; Ceriana, Piero; Mancini, Marco; Cirio, Serena; Pierucci, Paola; D'Artavilla Lupo, Nadia; Gadaleta, Felice; Morrone, Elisa; Fanfulla, Francesco

    2015-09-15

    Ventilation with continuous positive airway pressure (CPAP) is the gold standard therapy for obstructive sleep apnea (OSA). However, it was recently suggested that a novel mode of ventilation, Bilevel-auto, could be equally effective in treating patients unable to tolerate CPAP. The aim of this study was to investigate the ability of Bilevel-auto to treat OSA patients whose nocturnal ventilatory disturbances are not completely corrected by CPAP. We enrolled 66 consecutive OSA patients, not responsive to (group A) or intolerant of (group B) CPAP treatment, after a full night of manual CPAP titration in a laboratory. Full polysomnography data and daytime sleepiness score were compared for each group in the three different conditions: basal, during CPAP, and during Bilevel-auto. The apnea-hypopnea index decreased significantly during CPAP in both groups; however, in the group A, there was a further significant improvement during Bilevel-auto. The same trend was observed for oxygenation indices, while the distribution and the efficiency of sleep did not differ following the switch from CPAP to Bilevel-auto. This study confirmed the role of Bilevel-auto as an effective therapeutic alternative to CPAP in patients intolerant of this latter mode of ventilation. Moreover, extending the use of Bilevel-auto to those OSA patients not responsive to CPAP, we showed a significantly better correction of nocturnal respiratory disturbances. © 2015 American Academy of Sleep Medicine.

  3. Impact of the type of mask on the effectiveness of and adherence to continuous positive airway pressure treatment for obstructive sleep apnea*

    Science.gov (United States)

    de Andrade, Rafaela Garcia Santos; Piccin, Vivien Schmeling; Nascimento, Juliana Araújo; Viana, Fernanda Madeiro Leite; Genta, Pedro Rodrigues; Lorenzi-Filho, Geraldo

    2014-01-01

    Continuous positive airway pressure (CPAP) is the gold standard for the treatment of obstructive sleep apnea (OSA). Although CPAP was originally applied with a nasal mask, various interfaces are currently available. This study reviews theoretical concepts and questions the premise that all types of interfaces produce similar results. We revised the evidence in the literature about the impact that the type of CPAP interface has on the effectiveness of and adherence to OSA treatment. We searched the PubMed database using the search terms "CPAP", "mask", and "obstructive sleep apnea". Although we identified 91 studies, only 12 described the impact of the type of CPAP interface on treatment effectiveness (n = 6) or adherence (n = 6). Despite conflicting results, we found no consistent evidence that nasal pillows and oral masks alter OSA treatment effectiveness or adherence. In contrast, most studies showed that oronasal masks are less effective and are more often associated with lower adherence and higher CPAP abandonment than are nasal masks. We concluded that oronasal masks can compromise CPAP OSA treatment adherence and effectiveness. Further studies are needed in order to understand the exact mechanisms involved in this effect. PMID:25610507

  4. Impact of the type of mask on the effectiveness of and adherence to continuous positive airway pressure treatment for obstructive sleep apnea.

    Science.gov (United States)

    Andrade, Rafaela Garcia Santos de; Piccin, Vivien Schmeling; Nascimento, Juliana Araújo; Viana, Fernanda Madeiro Leite; Genta, Pedro Rodrigues; Lorenzi-Filho, Geraldo

    2014-01-01

    Continuous positive airway pressure (CPAP) is the gold standard for the treatment of obstructive sleep apnea (OSA). Although CPAP was originally applied with a nasal mask, various interfaces are currently available. This study reviews theoretical concepts and questions the premise that all types of interfaces produce similar results. We revised the evidence in the literature about the impact that the type of CPAP interface has on the effectiveness of and adherence to OSA treatment. We searched the PubMed database using the search terms "CPAP", "mask", and "obstructive sleep apnea". Although we identified 91 studies, only 12 described the impact of the type of CPAP interface on treatment effectiveness (n = 6) or adherence (n = 6). Despite conflicting results, we found no consistent evidence that nasal pillows and oral masks alter OSA treatment effectiveness or adherence. In contrast, most studies showed that oronasal masks are less effective and are more often associated with lower adherence and higher CPAP abandonment than are nasal masks. We concluded that oronasal masks can compromise CPAP OSA treatment adherence and effectiveness. Further studies are needed in order to understand the exact mechanisms involved in this effect.

  5. The Effect of Body Position on Pain Due to Nasal Continuous Positive Airway Pressure (CPAP in Premature Neonates: A Cross-Over Clinical Trial Study

    Directory of Open Access Journals (Sweden)

    Mahnaz Jabraeili

    2018-01-01

    Full Text Available Background The most common cause of admission to neonatal intensive care units (NICU is respiratory distress syndrome. One of the respiratory assistance methods is using nasal continuous positive airway pressure (CPAP. Regarding the importance of pain control which is one of the major priorities in neonatal nursing care, this study aimed to evaluate the effect of body position on pain due to nasal CPAP in premature neonates. Materials and Methods In this cross-over clinical trial, 50 premature neonates who were receiving nasal CPAP admitted to the NICU of Imam Reza Hospital, Kermanshah, Iran, were included. The neonates were randomly placed at three body positions (fetal, supine, and prone positions. Pain was measured by Astrid Lindgren Children’s Hospital Pain Scale Neonates (ALPS-Neo pain assessment scale. The collected data were analyzed using the SPSS software (Version 22.0. Results Significant difference existed regarding pain of nasal CPAP among body positions (p< 0.001. Mean (SD pain was 5.15 (0.822 in fetal position, 6.260 (0.747 in prone position and 7.326 (0.792 in supine position. Conclusion Body positioning in premature neonates under nasal CPAP in NICU can be effective as a non-pharmacologic method in alleviating pain due to nasal CPAP. Among the studied positions, the lowest pain score was seen in fetal position.

  6. Impact of Prophylactic Continuous Positive Airway Pressure on Transient Tachypnea of the Newborn and Neonatal Intensive Care Admission in Newborns Delivered by Elective Cesarean Section.

    Science.gov (United States)

    Celebi, Miray Yilmaz; Alan, Serdar; Kahvecioglu, Dilek; Cakir, Ufuk; Yildiz, Duran; Erdeve, Omer; Arsan, Saadet; Atasay, Begum

    2016-01-01

    This study aims to evaluate the effect of the prophylactic continuous positive airway pressure (CPAP) administration in the delivery room to newborns who were delivered by elective cesarean section (CS). Inborn infants with gestational age between 34(0/7) to 38(6/7) and born by elective CS were prospectively randomized to receive either prophylactic CPAP for 20 minutes via face mask or standardized care without CPAP in the delivery room. Primary outcomes were the incidence of transient tachypnea of the newborn (TTN) and neonatal intensive care unit (NICU) admission due to respiratory distress. A total of 259 infants with a mean gestational age of 37.7 ± 0.8 weeks and birth weight of 3,244 ± 477 g were included. A total of 134 infants received prophylactic CPAP and 125 received control standard care. The rate of NICU admission was significantly lower in prophylactic CPAP group (p = 0.045). Although the rate of TTN was lower in the prophylactic CPAP group, the difference was not statistically significant (p = 0.059). The rate of NICU admission due to respiratory distress was significantly higher in late-preterm cohort than early-term cohort (p CPAP administration decreases the rate of NICU admission without any side effect in late-preterm and early-term infants delivered by elective CS. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  7. [Effect of Continuous Positive Airway Pressure Treatment on Depression, Anxiety and Perceived Stress Levels in Patients with Obstructive Sleep Apnea Syndrome].

    Science.gov (United States)

    Çelik, Mustafa; Sarıkaya, Yasin; Acar, Mustafa; Kalenderoğlu, Aysun; Doğan, Sedat; Kaskalan, Emin; Karataş, Mehmet

    2016-01-01

    The aim of this study is to determine the effects of continuous positive airway pressure (CPAP) treatment on depression, anxiety, and perceived stress levels and to identify factors predictive of treatment efficacy in patients with obstructive sleep apnea syndrome (OSAS). This study included 51 patients admitted to the Adiyaman University Medical School Otorhinolaryngology Department or Eskisehir Yunus Emre State Hospital between January and September 2014 with one or more complaints including snoring, excessive daytime sleepiness, or apnea witnessed by the partner. Diagnosis of OSAS was made by polysomnography and CPAP treatment was initiated. Depression levels were assessed in all study subjects using the Hospital Anxiety and Depression Scale (HADS) at the start of treatment and at 3 months. Anxiety levels were assessed using both the HADS and the State and Trait Anxiety Inventory (STAI), and perceived stress level was assessed using the Perceived Stress Questionnaire (PSQ). After CPAP treatment, we observed significant decreases in both the Depression and Anxiety Subscales of the HADS, in the Trait Anxiety subscale of the STAI, and in the PSQ. An evaluation of the initial parameters that predict improvements in these scales revealed that snoring time predicted decreases in all scale scores. In OSAS patients CPAP treatment has positive effects on psychological parameters like depression, anxiety, and perceived stress. We suggest that possible psychogenic benefits should be considered when deciding to start CPAP treatment, particularly in patients with pronounced and extended snoring who may also have social problems.

  8. Role of bronchodilation and pattern of breathing in increasing tidal expiratory flow with progressive induced hypercapnia in chronic obstructive pulmonary disease.

    Science.gov (United States)

    Finucane, Kevin E; Singh, Bhajan

    2018-01-01

    Hypercapnia (HC) in vitro relaxes airway smooth muscle; in vivo, it increases respiratory effort, tidal expiratory flows (V̇ exp ), and, by decreasing inspiratory duration (Ti), increases elastic recoil pressure (Pel) via lung viscoelasticity; however, its effect on airway resistance is uncertain. We examined the contributions of bronchodilation, Ti, and expiratory effort to increasing V̇ exp with progressive HC in 10 subjects with chronic obstructive pulmonary disease (COPD): mean forced expiratory volume in 1 s (FEV 1 ) 53% predicted. Lung volumes (Vl), V̇ exp , esophageal pressure (Pes), Ti, and end-tidal Pco 2 ([Formula: see text]) were measured during six tidal breaths followed by an inspiratory capacity (IC), breathing air, and at three levels of HC. V̇ exp and V̇ with submaximal forced vital capacities breathing air (V̇ sFVC ) were compared. Pulmonary resistance ( Rl) was measured from the Pes-V̇ relationship. V̇ exp and Pes at end-expiratory lung volume (EELV) + 0.3 tidal volume [V̇ (0.3Vt) and Pes (0.3Vt) , respectively], Ti, and Rl correlated with [Formula: see text] ( P pulmonary disease (COPD), progressive HC increases tidal expiratory flows by inducing bronchodilation and via an increased rate of inspiration and lung viscoelasticity, a probable increase in lung elastic recoil pressure, both changes increasing expiratory flows, promoting lung emptying and a stable end-expiratory volume. Bronchodilation with HC occurred despite optimal standard bronchodilator therapy, suggesting that in COPD further bronchodilation is possible.

  9. Rapid shallow breathing

    Science.gov (United States)

    Tachypnea; Breathing - rapid and shallow; Fast shallow breathing; Respiratory rate - rapid and shallow ... Shallow, rapid breathing has many possible medical causes, including: Asthma Blood clot in an artery in the ...

  10. Sex differences in sleep disordered breathing in adults.

    Science.gov (United States)

    Lozo, Tijana; Komnenov, Dragana; Badr, M Safwan; Mateika, Jason H

    2017-11-01

    The prevalence of sleep disordered breathing is greater in men compared to women. This disparity could be due to sex differences in the diagnosis and presentation of sleep apnea, and the pathophysiological mechanisms that instigate this disorder. Women tend to report more non-typical symptoms of sleep apnea compared to men, and the presentation of apneic events are more prevalent in rapid compared to non-rapid eye movement sleep. In addition, there is evidence of sex differences in upper airway structure and mechanics and in neural mechanisms that impact on the control of breathing. The purpose of this review is to summarize the literature that addresses sex differences in sleep-disordered breathing, and to discuss the influence that upper airway mechanics, chemoreflex properties, and sex hormones have in modulating breathing during sleep in men and women. Published by Elsevier B.V.

  11. Use of continuous positive airway pressure (CPAP) in neonatal units--a survey of current preferences and practice in Germany.

    Science.gov (United States)

    Roehr, C C; Schmalisch, G; Khakban, A; Proquitté, H; Wauer, R R

    2007-04-26

    There is only limited evidence regarding the equipment or the settings (pressure and flow) at which CPAP should be applied in neonatal care. Aims of this nationwide survey of German neonatal units were to investigate (1) for which clinical indications CPAP was employed, (2) which CPAP equipment was used, (3) which CPAP settings were applied. A questionnaire on the use of CPAP was sent to all children's hospitals in Germany. Data were stratified and compared by level of medical care provided (non-academic children's hospital, academic teaching hospital and university children's hospital). 274 institutions were contacted by mailed questionnaire. The response rate was 86%, 90 non-academic children's hospitals, 119 academic teaching hospitals and 26 university children's hospitals replied. (1) There were no statistically significant difference in CPAP use between the institutions: 231 (98%) used CPAP for treating respiratory distress syndrome, 225 (96%) for treating apnoea-bradycardia-syndrome and 230 (98%) following extubation. (2) Commercial CPAP systems were employed by 71% of units, the others used a combination of different devices. Respirator generated CPAP was most commonly used. Exclusively mononasal CPAP was used by only 9%, and binasal CPAP by 55% of institutions. (3) Median CPAP was 4.5 cm H2O (range 3-7), median maximum CPAP was 7 cm H2O (range 4-10), with no statistically significant differences between the hospitals. Between units, CPAP was given via a broad range of CPAP systems and at varying pressure settings. The reported differences reflects personal experiences and preferences, rather than sound evidence from clinical trials.

  12. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Treatments and Therapies Airway Clearance Airway Clearance Techniques (ACTs) There are different ways to clear your airways. ... or caregiver. Older kids and adults can choose ACTs that they can do on their own. Share ...

  13. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... to loosen mucus from airway walls. See how different airway clearance techniques work to help you clear the thick, sticky mucus ... Offer their tips for fitting ACTs into daily life Airway Clearance Techniques | Webcast ... Facebook Twitter ...

  14. Sleep-Disordered Breathing in Heart Failure - A Therapeutic Dilemma.

    Science.gov (United States)

    Haruki, Nobuhiko; Floras, John S

    2017-06-23

    Sleep-disordered breathing (SDB) occurs in approximately 50% of patients with reduced left ventricular ejection fraction receiving contemporary heart failure (HF) therapies. Obstructive (OSA) and central sleep apneas (CSA) interrupt breathing by different mechanisms but impose qualitatively similar autonomic, chemical, mechanical, and inflammatory burdens on the heart and circulation. Because contemporary evidence-based drug and device HF therapies have little or no mitigating effect on the acute or long-term consequences of such stimuli, there is a sound mechanistic rationale for targeting SDB to reduce cardiovascular event rates and prolong life. However, the promise of observational studies and randomized trials of small size and duration describing a beneficial effect of treating SDB in HF via positive airway pressure was not realized in 2 recent randomized outcome-driven trials: SAVE, which evaluated the cardiovascular effect of treating OSA in a cohort without HF, and SERVE-HF, which reported the results of a strategy of random allocation of minute-ventilation-triggered adaptive servo-ventilation (ASV) for HF patients with CSA. Whether effective treatment of either OSA or CSA improves the HF trajectory by reducing cardiovascular morbidity or mortality has yet to be definitively established. ADVENT-HF, designed to determine the effect of treating both CSA and non-sleepy OSA HF patients with a peak-airflow triggered ASV algorithm, could resolve this present clinical equipoise concerning the treatment of SDB.

  15. Relationships between hippocampal activity and breathing patterns

    DEFF Research Database (Denmark)

    Harper, R M; Poe, G R; Rector, D M

    1998-01-01

    Single cell discharge, EEG activity, and optical changes accompanying alterations in breathing patterns, as well as the knowledge that respiratory musculature is heavily involved in movement and other behavioral acts, implicate hippocampal regions in some aspects of breathing control. The control...... is unlikely to reside in oscillatory breathing movements, because such patterns emerge in preparations retaining only the medulla (and perhaps only the spinal cord). However, momentary changes in breathing patterns induced by affect, startle, whole-body movement changes, or compensatory ventilatory changes...... of hippocampal contributions to breathing control should be viewed in the context that significant interactions exist between blood pressure changes and ventilation, and that modest breathing challenges, such as exposure to hypercapnia or to increased resistive loads, bring into action a vast array of brain...

  16. Impact of Compression Stockings vs. Continuous Positive Airway Pressure on Overnight Fluid Shift and Obstructive Sleep Apnea among Patients on Hemodialysis

    Directory of Open Access Journals (Sweden)

    Bruno C. Silva

    2017-05-01

    Full Text Available IntroductionObstructive sleep apnea (OSA is common in edematous states, notably in hemodialysis patients. In this population, overnight fluid shift can play an important role on the pathogenesis of OSA. The effect of compression stockings (CS and continuous positive airway pressure (CPAP on fluid shift is barely known. We compared the effects of CS and CPAP on fluid dynamics in a sample of patients with OSA in hemodialysis, through a randomized crossover study.MethodsEach participant performed polysomnography (PSG at baseline, during CPAP titration, and after 1 week of wearing CS. Neck circumference (NC and segmental bioelectrical impedance were done before and after PSG.ResultsFourteen patients were studied (53 ± 9 years; 57% men; body mass index 29.7 ± 6.8 kg/m2. Apnea–hypopnea index (AHI decreased from 20.8 (14.2; 39.6 at baseline to 7.9 (2.8; 25.4 during CPAP titration and to 16.7 (3.5; 28.9 events/h after wearing CS (CPAP vs. baseline, p = 0.004; CS vs. baseline, p = 0.017; and CPAP vs. CS, p = 0.017. Nocturnal intracellular trunk water was higher after wearing CS in comparison to baseline and CPAP (p = 0.03. CS reduced the fluid accumulated in lower limbs during the day, although not significantly. Overnight fluid shift at baseline, CPAP, and CS was −183 ± 72, −343 ± 220, and −290 ± 213 ml, respectively (p = 0.006. Overnight NC increased at baseline (0.7 ± 0.4 cm, decreased after CPAP (−1.0 ± 0.4 cm, and while wearing CS (−0.4 ± 0.8 cm (CPAP vs. baseline, p < 0.0001; CS vs. baseline, p = 0.001; CPAP vs. CS, p = 0.01.ConclusionCS reduced AHI by avoiding fluid retention in the legs, favoring accumulation of water in the intracellular component of the trunk, thus avoiding fluid shift to reach the neck. CPAP improved OSA by exerting local pressure on upper airway, with no impact on fluid redistribution. CPAP performed significantly better than CS

  17. Efficiency of Continuous Positive Airway Pressure or High-Frequency Jet Ventilation by Means a Nasooral Mask in the Treatment of Pulmonary Edema

    Directory of Open Access Journals (Sweden)

    J. Salantay

    2008-01-01

    Full Text Available Objective: to compare the efficiency of continuous positive airway pressure (CPAP and high-frequency jet ventilation by means of a mask (HFJV-M in the treatment of cardiogenic edema of the lung. Design: a retrospective study. Setting: Department of Anesthesiology and Intensive Medicine, Hospital NsP, Vranov, Slovakia. Subjects and methods. A hundred and ninety-six patients with varying cardiogenic edema of the lung were divided into 3 groups according to the severity of pulmonary edema (PE. By taking into account comparable pharmacotherapy, mean airway pressure, and FiO2, the authors compared the efficiency of CPAP (n=64 and HFJV-M (n=101 from the rate of changes in respiration rate, blood oxygenation, acid-base balance, and the duration of ventilation support and the length of stay in the intensive care unit (ICU. The results were assessed by the unpaired Student’s test. The procedure of artificial ventilation via HFJV-M was approved by the Professional and Ethics Committee, Ministry of Health in the Republic of Slovakia, in 1989 for clinical application. Results. Comparison of CPAP or HFJV-M used in mild PE that was called Phase 1 of PE revealed no statistically significant differences in the parameters being assessed. In severer forms of PE characterized as Phases 2 and 3, the use of HFJV-M in the first 3 hours of ventilation maintenance caused a rapider reduction in spontaneous respiration rate from 25—33 per min to 18—22 per min (p>0.01. The application of HFJV-M also showed a statistically significant difference in the correction rate of PaO2, pH, and oxygenation index (PaO2/FIO2 (p>0.01 predominantly within the first 2 hours of therapy. Comparison of the mean duration of necessary ventilation maintenance (CPAP versus HFJV-M: 10.9 versus 6.8 hours and the mean length of stay in the ICU (CPAP versus HFJV-N: 2.7 versus 2 days revealed a statistically significant difference (p>0.01 and p>0.05, respectively. Only 6.6% of the HFJV-M group

  18. 46 CFR 197.312 - Breathing supply hoses.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Breathing supply hoses. 197.312 Section 197.312 Shipping... GENERAL PROVISIONS Commercial Diving Operations Equipment § 197.312 Breathing supply hoses. (a) Each breathing supply hose must— (1) Have a maximum working pressure that is equal to or exceeds— (i) The maximum...

  19. Effects of heated humidification and topical steroids on compliance, nasal symptoms, and quality of life in patients with obstructive sleep apnea syndrome using nasal continuous positive airway pressure.

    LENUS (Irish Health Repository)

    Ryan, Silke

    2012-02-01

    BACKGROUND: Nasal side effects are common in patients with obstructive sleep apnea syndrome (OSAS) starting on nasal continuous positive airway pressure (CPAP) therapy. We tested the hypothesis that heated humidification or nasal topical steroids improve compliance, nasal side effects and quality of life in this patient group. METHODS: 125 patients with the established diagnosis of OSAS (apnea\\/hypopnea index > or = 10\\/h), who tolerated CPAP via a nasal mask, and who had a successful CPAP titration were randomized to 4 weeks of dry CPAP, humidified CPAP or CPAP with additional topical nasal steroid application (fluticasone, GlaxoWellcome). Groups were similar in all demographic variables and in frequency of nasal symptoms at baseline. Outcome measures were objective compliance, quality of life (short form 36), subjective sleepiness (Epworth Sleepiness Scale score) and nasal symptoms such as runny, dry or blocked nose, sneezing and headaches; all variables assessed using a validated questionnaire and by direct interview. RESULTS: There was no difference in compliance between groups after 4 weeks (dry: 5.21 +\\/- 1.66 h\\/night, fluticasone: 5.66 +\\/- 1.68, humidifier: 5.21 +\\/- 1.84; p = 0.444). Quality of life and subjective sleepiness improved in all groups, but there were no differences in the extent of improvement. Nasal Symptoms were less frequently reported in the humidifier group (28%) than in the remaining groups (dry: 70%, fluticasone: 53%, p = 0.002). However, the addition of fluticasone resulted in increased frequency of sneezing. CONCLUSION: The addition of a humidifier, but not nasal steroids decreases the frequency of nasal symptoms in unselected OSAS patients initiating CPAP therapy; however compliance and quality of life remain unaltered.

  20. Sleep apnea-related risk of motor vehicle accidents is reduced by continuous positive airway pressure: Swedish Traffic Accident Registry data.

    Science.gov (United States)

    Karimi, Mahssa; Hedner, Jan; Häbel, Henrike; Nerman, Olle; Grote, Ludger

    2015-03-01

    Obstructive sleep apnea (OSA) is associated with an increased risk of motor vehicle accidents (MVAs). The rate of MVAs in patients suspected of having OSA was determined and the effect of continuous positive airway pressure (CPAP) was investigated. MVA rate in patients referred for OSA was compared to the rate in the general population using data from the Swedish Traffic Accident Registry (STRADA), stratified for age and calendar year. The risk factors for MVAs, using demographic and polygraphy data, and MVA rate before and after CPAP were evaluated in the patient group. Clinical sleep laboratory and population based control (n = 635,786). There were 1,478 patients, male sex 70.4%, mean age 53.6 (12.8) y. CPAP. The number of accidents (n = 74) among patients was compared with the expected number (n = 30) from a control population (STRADA). An increased MVA risk ratio of 2.45 was found among patients compared with controls (P accident risk was most prominent in the elderly patients (65-80 y, seven versus two MVAs). In patients, driving distance (km/y), EDS (Epworth Sleepiness score ≥ 16), short habitual sleep time (≤5 h/night), and use of hypnotics were associated with increased MVA risk (odds ratios 1.2, 2.1, 2.7 and 2.1, all P ≤ 0.03). CPAP use ≥ 4 h/night was associated with a reduction of MVA incidence (7.6 to 2.5 accidents/1,000 drivers/y). The MVA risk in this large cohort of unselected patients with OSA suggests a need for accurate tools to identify individuals at risk. Sleep apnea severity (e.g., apnea-hypopnea index) failed to identify patients at risk. © 2015 Associated Professional Sleep Societies, LLC.

  1. Control of OSA during automatic positive airway pressure titration in a clinical case series: predictors and accuracy of device download data.

    Science.gov (United States)

    Huang, Hsin-Chia Carol; Hillman, David R; McArdle, Nigel

    2012-09-01

    To investigate the factors associated with physiologic control of obstructive sleep apnea (OSA) during automatic positive airway pressure (APAP) titration in a clinical series. To also assess the usefulness of apnea-hypopnea index (AHI) data downloaded from the APAP device (Dev AHI). Retrospective review of a consecutive series of patients with OSA who underwent APAP titration (Autoset Spirit, ResMed, Bella Vista, New South Wales, Australia ) with simultaneous polysomnographic (PSG) monitoring in the sleep laboratory. Tertiary sleep clinic. There were 190 consecutive patients with OSA referred for APAP titration. There were 58% of patients who achieved optimal or good control of OSA (titration PSG AHI titration. The independent predictors of titration PSG AHI were a history of cardiac disease and elevated central apnea and arousal indices during the diagnostic study. Although the median and interquartile range (IQR) AHI from the device (7.0, 3.9-11.6 events/hr) was only slightly less than the PSG AHI (7.8, 3.9-14.4 events/hr, P = 0.04) during titration, case-by-case agreement between the two measures was poor (chi-square titration is often poor, and close clinical follow-up is particularly needed in patients with a history of cardiac disease or with high arousal or central apnea indices on the diagnostic study. Device AHI does not reliably assess control during APAP titration, and PSG assessment may be required if clinical response to treatment is poor. The findings relate to the ResMed AutoSet device and may not apply to other devices.

  2. The Effects of Massage with Coconut and Sunflower Oils on Oxygen Saturation of Premature Infants with Respiratory Distress Syndrome Treated With Nasal Continuous Positive Airway Pressure

    Directory of Open Access Journals (Sweden)

    Sousan Valizadeh

    2012-11-01

    Full Text Available Introduction: Nowadays particular emphasis is placed on the developmental aspects of premature infants care. Massage therapy is one of the best-known methods of caring. Due to the minimal touch policy in neonatal intensive care units (NICUs, massaging is not usually performed on premature infants. However, there is not sufficient evidence to support the claim that newborn infants with complex medical conditions should not be massaged. This study aimed to determine the effects of massage with coconut and sunflower oils on oxygen saturation of infants with respiratory distress syndrome (RDS treated with nasal continuous positive airway pressure (NCPAP. Methods: This was a randomized controlled trial on 90 newborns who were admitted to Alzahra Hospital (Tabriz, Iran. The infants were divided into control and massage therapy groups (massage with coconut and sunflower oils. Data was collected using a hospital documentation form. A 15-minute daily massage was performed for 3 days. Respiratory rate (RR, fraction of inspired oxygen (FiO2 and oxygen saturation were measured 5 minutes before the massage, 3 times during the massage, and 5 minutes after the massage. The collected data was analyzed using a mixed model. Results: In comparison to coconut oil and control groups, mean oxygen saturation of sunflower oil group was improved. In addition, the coconut massage group showed lower oxygen saturation than the control group but was all values were within the normal range. Although massage decreased oxygen saturation, there was no need to increase FiO2. Conclusion: Massage therapy can provide developmental care for infants treated with NCPAP.

  3. The Effect of Non-nutritive Sucking on Transcutaneous Oxygen Saturation in Neonates under the Nasal Continuous Positive Airway Pressure (CPAP

    Directory of Open Access Journals (Sweden)

    Mousa Ahmadpour-kacho

    2017-03-01

    Full Text Available BackgroundSeveral beneficial effects of non-nutritive sucking in infants, including the physiological stability, relaxation, better transition from tube feeding to oral feeding have been reported. But its effect on oxygen saturation in neonates under the Nasal Continuous Positive Airway Pressure (NCPAPو (is not so clear. This study aimed to investigate the effects of non-nutritive sucking on transcutaneous oxygen saturation levels of neonates treated with NCPAP.Materials and MethodsThis quasi-experimental study was done on 25 preterm neonates, hospitalized with a diagnosis of respiratory distress, required NCPAP, in the neonatal intensive care unit (NICU at the Ayatollah Rouhani Hospital and Babol Clinic, North of Iran. Non-nutritive sucking was elicited by a standard pacifier appropriate to their age one hour a day, and the mean oxygen saturation was measured before and after intervention by cardiopulmonary monitoring (Saadat Co., Iran. Data analyzed using SPSS-18.0 software.ResultsIn the 25 cases studied, the mean oxygen saturation values ​​before performing non-nutritive sucking was 96.31±2.88%, which was changed to 98.35±1.6% after intervention, and this increase was statistically significant (P = 0.004.Results showed that the gender, birth weight and gestational age of neonates had no effect on mean Blood oxygen saturation (SpO2level.ConclusionAccording to the results, using the non-nutritive sucking in premature neonates under the NCPAP, can improve oxygenation.

  4. Influence of marital status and employment status on long-term adherence with continuous positive airway pressure in sleep apnea patients.

    Science.gov (United States)

    Gagnadoux, Frédéric; Le Vaillant, Marc; Goupil, François; Pigeanne, Thierry; Chollet, Sylvaine; Masson, Philippe; Humeau, Marie-Pierre; Bizieux-Thaminy, Acya; Meslier, Nicole

    2011-01-01

    Long-term adherence is a major issue in patients receiving home continuous positive airway pressure (CPAP) therapy for obstructive sleep apnea-hypopnea syndrome (OSAHS). In a multicenter prospective cohort (the Institut de Recherche en Santé Respiratoire des Pays de la Loire [IRSR] sleep cohort) of consecutive OSAHS patients in whom CPAP had been prescribed for at least 90 days, we studied the impact on long-term treatment adherence of socioeconomic factors, patients and disease characteristics prior to CPAP initiation. Among 1,141 patients in whom CPAP had been prescribed for an average of 504±251 days (range: 91 to 1035), 674 (59%) were adherent with a mean daily use of CPAP≥4 h (mean: 6.42±1.35 h). Stepwise regression analysis identified 4 independent factors of CPAP adherence including apnea-hypopnea index (AHI) (OR: 1.549, 95%CI 1.163 to 2.062 for AHI≥30 vs. AHIstatus (OR: 1.414, 95%CI 1.097-1.821 for retired vs. employed; p = 0.007) and marital status (OR: 1.482, 95%CI 1.088-2.019 for married or living as a couple vs. living alone; p = 0.01). Age, gender, Epworth sleepiness scale, depressive syndrome, associated cardiovascular morbidities, educational attainment and occupation category did not influence CPAP adherence. Marital status and employment status are independent factors of CPAP adherence in addition to BMI and disease severity. Patients living alone and/or working patients are at greater risk of non-adherence, whereas adherence is higher in married and retired patients. These findings suggest that the social context of daily life should be taken into account in risk screening for CPAP non-adherence. Future interventional studies targeting at-risk patients should be designed to address social motivating factors and work-related barriers to CPAP adherence.

  5. Transitory increased blood pressure after upper airway surgery for snoring and sleep apnea correlates with the apnea-hypopnea respiratory disturbance index

    Directory of Open Access Journals (Sweden)

    M.T.M. Araújo

    2003-12-01

    Full Text Available A transitory increase in blood pressure (BP is observed following upper airway surgery for obstructive sleep apnea syndrome but the mechanisms implicated are not yet well understood. The objective of the present study was to evaluate changes in BP and heart rate (HR and putative factors after uvulopalatopharyngoplasty and septoplasty in normotensive snorers. Patients (N = 10 were instrumented for 24-h ambulatory BP monitoring, nocturnal respiratory monitoring and urinary catecholamine level evaluation one day before surgery and on the day of surgery. The influence of postsurgery pain was prevented by analgesic therapy as confirmed using a visual analog scale of pain. Compared with preoperative values, there was a significant (P < 0.05 increase in nighttime but not daytime systolic BP (119 ± 5 vs 107 ± 3 mmHg, diastolic BP (72 ± 4 vs 67 ± 2 mmHg, HR (67 ± 4 vs 57 ± 2 bpm, respiratory disturbance index (RDI characterized by apnea-hypopnea (30 ± 10 vs 13 ± 4 events/h of sleep and norepinephrine levels (22.0 ± 4.7 vs 11.0 ± 1.3 µg l-1 12 h-1 after surgery. A positive correlation was found between individual variations of BP and individual variations of RDI (r = 0.81, P < 0.01 but not between BP or RDI and catecholamines. The visual analog scale of pain showed similar stress levels on the day before and after surgery (6.0 ± 0.8 vs 5.0 ± 0.9 cm, respectively. These data strongly suggest that the cardiovascular changes observed in patients who underwent uvulopalatopharyngoplasty and septoplasty were due to the increased postoperative RDI.

  6. News from the Breath Analysis Summit 2011.

    Science.gov (United States)

    Corradi, Massimo; Mutti, Antonio

    2012-06-01

    (oxygen, nitrogen, water vapour and CO(2)) in patient respiratory monitoring have served as a platform for technological growth in clinical breath-testing applications. A few exhaled breath tests have demonstrated clinical utility and are in widespread use, and several FDA-approved devices are available. These widely used exhaled breath tests include detection of blood alcohol concentration and exhaled CO(2). Other clinical applications of exhaled breath analysis include testing for H. pylori infection, lactose intolerance, heart transplant rejection and, more recently, monitoring of airway inflammation by means of exhaled NO. Examination of exhaled breath has the potential to change the existing routine approaches in human medicine. The rapidly developing new analytical and computer technologies along with novel, unorthodox ideas are prerequisites for future advances in this field. Scientists who participated in the Breath Analysis Summit 2011 were invited to submit a full length paper to the Journal of Breath Research and this issue includes eight articles which describe the different applications of breath analysis. We thank all the authors for their valuable contribution and we trust that this collection will provide useful information and an update to this rapidly evolving field, giving an example of integration among scientists who address the same topic-breath analysis-from different and complementary perspectives, from basic to clinical research.

  7. Retrotracheal Extraskeletal Ewing's Sarcoma: Case Report and Discussion on Airway Management.

    Science.gov (United States)

    Van Der Meer, Graeme; Linkhorn, Hannah; Gruber, Maayan; Mahadevan, Murali; Barber, Colin

    2017-03-01

    Extraskeletal Ewing's sarcoma is a rare tumor, and the management of airway compromise in case of cervical Ewing's sarcoma has not been established. This report describes the case of a patient with retrotracheal Ewing's sarcoma and discusses a successful approach to airway management. A 12-year-old male presented with a 2-week history of sore throat and sleep-disordered breathing and 48 hours of stridor. Imaging confirmed a retrotracheal soft tissue mass with airway compromise. A planned and controlled approach to his airway management resulted in a secure airway prior to definitive treatment.

  8. Tonsillectomy or adenotonsillectomy versus non-surgical management for obstructive sleep-disordered breathing in children

    NARCIS (Netherlands)

    Venekamp, Roderick P; Hearne, Benjamin J; Chandrasekharan, Deepak; Blackshaw, Helen; Lim, Jerome; Schilder, Anne G M

    2015-01-01

    BACKGROUND: Obstructive sleep-disordered breathing (oSDB) is a condition that encompasses breathing problems when asleep, due to an obstruction of the upper airways, ranging in severity from simple snoring to obstructive sleep apnoea syndrome (OSAS). It affects both children and adults. In children,

  9. Wire-guided (Seldinger technique intubation through a face mask in urgent, difficult and grossly distorted airways

    Directory of Open Access Journals (Sweden)

    Jake M Heier

    2012-01-01

    Full Text Available We report two cases of successful urgent intubation using a Seldinger technique for airway management through an anesthesia facemask, while maintaining ventilation in patients with difficult airways and grossly distorted airway anatomy. In both cases, conventional airway management techniques were predicted to be difficult or impossible, and a high likelihood for a surgical airway was present. This technique was chosen as it allows tracheal tube placement through the nares during spontaneous ventilation with the airway stented open and oxygen delivery with either continuous positive airway pressure and/or pressure support ventilation. This unhurried technique may allow intubation when other techniques are unsuitable, while maintaining control of the airway.

  10. Influence of Head and Neck Position on Oropharyngeal Leak Pressure and Cuff Position with the ProSeal Laryngeal Mask Airway and the I-Gel: A Randomized Clinical Trial

    Directory of Open Access Journals (Sweden)

    Sandeep Kumar Mishra

    2015-01-01

    Full Text Available Background. This study was designed to assess and compare the effect of head and neck position on the oropharyngeal leak pressures and cuff position (employing fibreoptic view of the glottis and ventilation scores between ProSeal LMA and the I-gel. Material and Methods. After induction of anesthesia, the supraglottic device was inserted and ventilation confirmed. The position of the head was randomly changed from neutral to flexion, extension, and lateral rotation (left. The oropharyngeal leak pressures, fibreoptic view of glottis, ventilation scores, and delivered tidal volumes and end tidal CO2 were noted in all positions. Results. In both groups compared with neutral position, oropharyngeal leak pressures were significantly higher with flexion and lower with extension but similar with rotation of head and neck. However the oropharyngeal leak pressure was significantly higher for ProSeal LMA compared with the I-gel in all positions. Peak airway pressures were significantly higher with flexion in both groups (however this did not affect ventilation, lower with extension in ProSeal group, and comparable in I-gel group but did not change significantly with rotation of head and neck in both groups. Conclusion. Effective ventilation can be done with both ProSeal LMA and I-gel with head in all the above positions. ProSeal LMA has a better margin of safety than I-gel due to better sealing pressures except in flexion where the increase in airway pressure is more with the former. Extreme precaution should be taken in flexion position in ProSeal LMA.

  11. Continuous Positive Airway Pressure (CPAP)

    Science.gov (United States)

    ... Sleep Apnea? Lifestyle change including weight loss and exercise can help to improve sleep apnea and its related health problems. Sleep positioning and oral appliances have also been found to be effective. In cases when non-invasive treatments fail, a ...

  12. The effect of sleep onset on upper airway muscle activity in patients with sleep apnoea versus controls

    Science.gov (United States)

    Fogel, Robert B; Trinder, John; White, David P; Malhotra, Atul; Raneri, Jill; Schory, Karen; Kleverlaan, Darci; Pierce, Robert J

    2005-01-01

    Pharyngeal dilator muscles are important in the pathophysiology of obstructive sleep apnoea syndrome (OSA). We have previously shown that during wakefulness, the activity of both the genioglossus (GGEMG) and tensor palatini (TPEMG) is greater in patients with OSA compared with controls. Further, EMG activity decreases at sleep onset, and the decrement is greater in apnoea patients than in healthy controls. In addition, it is known that the prevalence of OSA is greater in middle-aged compared with younger men. Thus, we had two goals in this study. First we compared upper airway muscle activity between young and middle-aged healthy men compared with men with OSA. We also explored the mechanisms responsible for the decrement in muscle activity at sleep onset in these groups. We investigated muscle activity, ventilation , and upper airway resistance (UAR) during wakefulness and sleep onset (transition from α to θ EEG activity) in all three groups. Measurements were obtained during basal breathing (BB) and nasal continuous positive airway pressure (CPAP) was applied to reduce negative pressure-mediated muscle activation). We found that during wakefulness there was a gradation of GGEMG and UAR (younger < older < OSA) and that muscle activity was reduced by the application of nasal CPAP (to a greater degree in the OSA patients). Although CPAP eliminated differences in UAR during wakefulness and sleep, GGEMG remained greater in the OSA patients. During sleep onset, a greater initial fall in GGEMG was seen in the OSA patients followed by subsequent muscle recruitment in the third to fifth breaths following the α to θ transition. On the CPAP night, and GGEMG still fell further in the OSA patients compared with control subjects. CPAP prevented the rise in UAR at sleep onset along with the associated recruitment in GGEMG. Differences in TPEMG among the groups were not significant. These data suggest that the middle-aged men had upper airway function midway between that of

  13. Optimal ventilatory patterns in periodic breathing.

    Science.gov (United States)

    Ghazanshahi, S D; Khoo, M C

    1993-01-01

    The goal of this study was to determine whether periodic breathing (PB), which is highly prevalent during sleep at high altitudes, imposes physiological penalties on the respiratory system in the absence of any accompanying disease. Using a computer model of respiratory gas exchange, we compared the effects of a variety of PB patterns on the chemical and mechanical costs of breathing to those resulting from regular tidal breathing. Although PB produced considerable fluctuation in arterial blood gas tensions, for the same cycle-averaged ventilation, higher arterial oxygen saturation and lower arterial carbon dioxide levels were achieved. This result can be explained by the fact that the combination of large breaths and apnea in PB leads to a substantial reduction in dead space ventilation. At the same time, the savings in mechanical cost achieved by the respiratory muscles during apnea partially offset the increase during the breathing phase. Consequently, the "pressure cost," a criterion based on mean inspiratory pressure, was elevated only slightly, although the average work rate of breathing increased significantly. We found that, at extreme altitudes, PB patterns with clusters of 2 to 4 large breaths that alternate with apnea produce the highest arterial oxygenation levels and lowest pressure costs. The common occurrence of PB patterns with closely similar features has been reported in sleeping healthy sojourners at extreme altitudes. Taken together, these findings suggest that PB favors a reduction in the oxygen demands of the respiratory muscles and therefore may not be as detrimental as it is generally believed to be.

  14. Optimization of sampling parameters for standardized exhaled breath sampling.

    Science.gov (United States)

    Doran, Sophie; Romano, Andrea; Hanna, George B

    2017-09-05

    The lack of standardization of breath sampling is a major contributing factor to the poor repeatability of results and hence represents a barrier to the adoption of breath tests in clinical practice. On-line and bag breath sampling have advantages but do not suit multicentre clinical studies whereas storage and robust transport are essential for the conduct of wide-scale studies. Several devices have been developed to control sampling parameters and to concentrate volatile organic compounds (VOCs) onto thermal desorption (TD) tubes and subsequently transport those tubes for laboratory analysis. We conducted three experiments to investigate (i) the fraction of breath sampled (whole vs. lower expiratory exhaled breath); (ii) breath sample volume (125, 250, 500 and 1000ml) and (iii) breath sample flow rate (400, 200, 100 and 50 ml/min). The target VOCs were acetone and potential volatile biomarkers for oesophago-gastric cancer belonging to the aldehyde, fatty acids and phenol chemical classes. We also examined the collection execution time and the impact of environmental contamination. The experiments showed that the use of exhaled breath-sampling devices requires the selection of optimum sampling parameters. The increase in sample volume has improved the levels of VOCs detected. However, the influence of the fraction of exhaled breath and the flow rate depends on the target VOCs measured. The concentration of potential volatile biomarkers for oesophago-gastric cancer was not significantly different between the whole and lower airway exhaled breath. While the recovery of phenols and acetone from TD tubes was lower when breath sampling was performed at a higher flow rate, other VOCs were not affected. A dedicated 'clean air supply' overcomes the contamination from ambient air, but the breath collection device itself can be a source of contaminants. In clinical studies using VOCs to diagnose gastro-oesophageal cancer, the optimum parameters are 500mls sample volume

  15. A Novel Therapy for Chronic Sleep-Onset Insomnia: A Retrospective, Nonrandomized Controlled Study of Auto-Adjusting, Dual-Level, Positive Airway Pressure Technology.

    Science.gov (United States)

    Krakow, Barry; Ulibarri, Victor A; McIver, Natalia D; Nadorff, Michael R

    2016-09-29

    Evidence indicates that behavioral or drug therapy may not target underlying pathophysiologic mechanisms for chronic insomnia, possibly due to previously unrecognized high rates (30%-90%) of sleep apnea in chronic insomnia patients. Although treatment studies with positive airway pressure (PAP) demonstrate decreased severity of chronic sleep maintenance insomnia in patients with co-occurring sleep apnea, sleep-onset insomnia has not shown similar results. We hypothesized advanced PAP technology would be associated with decreased sleep-onset insomnia severity in a sample of predominantly psychiatric patients with comorbid sleep apnea. We reviewed charts of 74 severe sleep-onset insomnia patients seen from March 2011 to August 2015, all meeting American Academy of Sleep Medicine Work Group criteria for a chronic insomnia disorder and all affirming behavioral and psychological origins for insomnia (averaging 10 of 18 indicators/patient), as well as averaging 2 or more psychiatric symptoms or conditions: depression (65.2%), anxiety (41.9%), traumatic exposure (35.1%), claustrophobia (29.7%), panic attacks (28.4%), and posttraumatic stress disorder (20.3%). All patients failed continuous or bilevel PAP and were manually titrated with auto-adjusting PAP modes (auto-bilevel and adaptive-servo ventilation). At 1-year follow-up, patients were compared through nonrandom assignment on the basis of a PAP compliance metric of > 20 h/wk (56 PAP users) versus insomnia severity (Hedges' g = 1.72) and sleep-onset insomnia (g = 2.07) compared to partial users (g = 1.04 and 0.91, respectively). Both global and sleep-onset insomnia severity decreased below moderate levels in PAP users compared to partial users whose outcomes persisted at moderately severe levels. In a nonrandomized controlled retrospective study, advanced PAP technology (both auto-bilevel and adaptive servo-ventilation) were associated with large decreases in insomnia severity for sleep-onset insomnia patients who

  16. Oral health in patients treated by positive airway pressure for obstructive sleep apnea: a population-based case-control study.

    Science.gov (United States)

    Carra, M C; Thomas, F; Schmitt, A; Pannier, B; Danchin, N; Bouchard, Ph

    2016-03-01

    Recent epidemiological evidence suggests that patients with obstructive sleep apnea (OSA) have an increased risk of periodontal disease. Little is known about the oral health of OSA patients treated by continuous or bi-level positive airway pressure (CPAP/BiPAP). The aim of this population-based case-control study was to compare oral health variables (amount of plaque, calculus, gingival inflammation, and masticatory function) between CPAP/BiPAP users and control subjects. The study population was retrieved from a French cohort examined between 2012 and 2013 at the Centre d'Investigations Préventives et Cliniques of Paris. Cases were selected if they reported to be treated by CPAP/BiPAP; controls were age-, gender-, and BMI-matched based on a 1:2 ratio. Univariate and logistic regression analyses were performed for group comparisons. Over a total of 20,436 subjects, 287 CPAP/BiPAP users (mean age (SD) 57.6 years (11.5); 76.3 % males) who underwent medical and dental examinations were compared with 574 matched controls (no OSA, no CPAP/BiPAP). CPAP/BiPAP users reported significantly higher prevalence of diabetes (15.6 vs. 10.3 %; p = 0.012; odds ratio (OR) 1.68), history of hypertension (36.5 vs. 26.1 %; p = 0.003; OR 1.62), cardiovascular diseases (14.1 vs. 8.8 %; p = 0.029; OR 1.69), and sleep complaints (59 vs. 34.4 %; p = 0.0001; OR 2.75). CPAP/BiPAP users also showed higher levels of depression and stress compared to controls. However, no group difference was observed for the amount of dental plaque, calculus, gingival inflammation, and masticatory function. Oral health of OSA patients treated by CPAP/BiPAP is comparable to that of matched controls in terms of amount of plaque, gingival inflammation, and masticatory function.

  17. Effects of continuous positive airway pressure on anxiety, depression, and major cardiac and cerebro-vascular events in obstructive sleep apnea patients with and without coronary artery disease.

    Science.gov (United States)

    Lee, Ming-Chung; Shen, Yu-Chih; Wang, Ji-Hung; Li, Yu-Ying; Li, Tzu-Hsien; Chang, En-Ting; Wang, Hsiu-Mei

    2017-01-01

    Obstructive sleep apnea (OSA) is associated with bad cardiovascular outcomes and a high prevalence of anxiety and depression. This study investigated the effects of continuous positive airway pressure (CPAP) on the severity of anxiety and depression in OSA patients with or without coronary artery disease (CAD) and on the rate of cardio- and cerebro-vascular events in those with OSA and CAD. This prospective study included patients with moderate-to-severe OSA, with or without a recent diagnosis of CAD; all were started on CPAP therapy. Patients completed the Chinese versions of the Beck Anxiety Inventory (BAI) and Beck Depression Inventory-II (BDI-II) at baseline and after 6-month follow-up. The occurrence of major adverse cardiac and cerebrovascular events (MACCE) was assessed every 3 months up to 1 year. BAI scores decreased from 8.5 ± 8.4 at baseline to 5.4 ± 6.9 at 6 months in CPAP-compliant OSA patients without CAD ( P < 0.05). BAI scores also decreased from 20.7 ± 14.9 to 16.1 ± 14.5 in CPAP-compliant OSA patients with CAD. BDI-II scores decreased in CPAP-compliant OSA patients without CAD (from 11.1 ± 10.7 at baseline to 6.6 ± 9.5 at 6 months) and in CPAP-compliant OSA patients with CAD (from 20.4 ± 14.3 to 15.9 ± 7.3). In addition, there was a large effect size (ES) of BAI and BDI in 6-month CPAP treatment of OSA patients with CAD and a large ES in those with OSA under CPAP treatment. In OSA patients with CAD, the occurrence of MACCE was significantly lower in CPAP-compliant patients than that in CPAP noncompliant patients (11% in CPAP compliant and 50% in noncompliant; P < 0.05). CPAP improved anxiety and depression in OSA patients regardless of CAD. In OSA patients with CAD, CPAP-compliant patients had a lower 1-year rate of MACCE than CPAP-noncompliant patients.

  18. A randomised controlled trial of flow driver and bubble continuous positive airway pressure in preterm infants in a resource-limited setting.

    Science.gov (United States)

    Mazmanyan, P; Mellor, K; Doré, C J; Modi, N

    2016-01-01

    The variable-flow flow driver (FD; EME) and continuous-flow bubble (Fisher-Paykel) continuous positive airway pressure (CPAP) systems are widely used. As these differ in cost and technical requirements, determining comparative efficacy is important particularly where resources are limited. We performed a randomised, controlled, equivalence trial of CPAP systems. We specified the margin of equivalence as 2 days. We analysed binary variables by logistical regression adjusted for gestation, and log transformed continuous variables by multiple linear regression adjusted for gestation, sex and antenatal steroids. A neonatal unit with no blood gas analyser or surfactant availability and limited X-ray and laboratory facilities Neonates CPAP at delivery followed by randomisation to FD or bubble (B). Primary outcome included total days receiving CPAP; secondary outcomes included days receiving CPAP, supplemental oxygen, ventilation, death, pneumothorax and nasal excoriation. We randomised 125 infants (B 66, FD 59). Differences in infant outcomes on B and FD were not statistically significant. The median (range) for CPAP days for survivors was B 0.8 (0.04 to 17.5), FD 0.5 (0.04 to 5.3). B:FD (95% CI) ratios were CPAP days 1.3 (0.9 to 2.1), CPAP plus supplementary oxygen days 1.2 (0.7 to 1.9). B:FD (95% CI) ORs were death 2.3 (0.2 to 28), ventilation 2.1 (0.5 to 9), nasal excoriation 1.2 (0.2 to 8) and pneumothorax 2.4 (0.2 to 26). In a resource-limited setting we found B CPAP equivalent to FD CPAP in the total number of days receiving CPAP within a margin of 2 days. ISRCTN22578364. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  19. Initial treatment of respiratory distress syndrome with nasal intermittent mandatory ventilation versus nasal continuous positive airway pressure: A randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Amir-Mohammad Armanian

    2014-01-01

    Full Text Available Background: Neonatal respiratory distress syndrome (RDS in premature infants who survived and its complications are a common problem. Due to high morbidity and mechanical ventilation (MV nowadays researchers in interested minimizing MV. To determine, in very low birth weight (BW preterm neonates with RDS, if initial treatment with nasal intermittent mandatory ventilation (early NIMV compared with early nasal continuous positive airway pressure (early NCPAP obtains more favorable outcomes in terms of the duration of treatment, and the need for endotracheal tube ventilation. Methods: In this single-center randomized control trial study, infants (BW ≤ 1500 g and/or gestational age ≤ 34 weeks with respiratory distress were considered eligible. Forty-four infants were randomly assigned to receive early-NIMV and 54 comparable infants to early-NCPAP. Surfactants were given, when FIO 2 requirement was of >30%. Primary outcomes were failure of noninvasive respiratory support, that is, the need for MV in the first 48 h of life and for the duration of noninvasive respiratory support in each group. Results: 98 infants were enrolled (44 in the NIMV and 54 in the NCPAP group. The Preventive power of MV of NIMV usage (95.5% was not lower than the NCPAP (98.1% strength (hazard ratio: 0.21 (95% confidence interval: 0.02-2.66; P: 0.23. The duration of noninvasive respiratory support in the NIMV group was significantly shorter than NCPAP (the median (range was 24 (18.00-48.00 h versus 48.00 (22.00-120.00 h in NIMV versus NCPAP groups; P < 0.001. Similarly, the duration of dependency on oxygen was less, for NIMV (the median (range was 96.00 (41.00-504.00 h versus144.00 (70.00-1130.00 h in NIMV versus NCPAP groups; P: 0.009. Interestingly, time to full enteral feeds and length of hospital stay were more favorable in the NIMV versus the NCPAP group. Conclusions: Initial treatment of RDS with NIMV was safe, and well tolerated. Furthermore, NIMV had excellent

  20. Auto-titrating continuous positive airway pressure treatment for obstructive sleep apnoea after acute quadriplegia (COSAQ): study protocol for a randomized controlled trial.

    Science.gov (United States)

    Berlowitz, David J; Ayas, Najib; Barnes, Maree; Brown, Douglas J; Cistulli, Peter A; Geraghty, Tim; Graham, Alison; Lee, Bonsan Bonne; Morris, Meg; O'Donoghue, Fergal; Rochford, Peter D; Ross, Jack; Singhal, Balraj; Spong, Jo; Wadsworth, Brooke; Pierce, Robert J

    2013-06-19

    Quadriplegia is a severe, catastrophic injury that predominantly affects people early in life, resulting in lifelong physical disability. Obstructive sleep apnoea is a direct consequence of quadriplegia and is associated with neurocognitive deficits, sleepiness and reduced quality of life. The usual treatment for sleep apnoea is nasal continuous positive airway pressure (CPAP); however, this is poorly tolerated in quadriplegia. To encourage patients to use this therapy, we have to demonstrate that the benefits outweigh the inconvenience. We therefore propose a prospective, multinational randomized controlled trial of three months of CPAP for obstructive sleep apnoea after acute quadriplegia. Specialist spinal cord injury centres across Australia, New Zealand, the UK and Canada will recruit medically stable individuals who have sustained a (new) traumatic quadriplegia (complete or incomplete second cervical to first thoracic level lesions). Participants will be screened for obstructive sleep apnoea using full, portable sleep studies. Those with an apnoea hypopnoea index greater than 10 per hour will proceed to an initial three-night trial of CPAP. Those who can tolerate CPAP for at least 4 hours on at least one night of the initial trial will be randomized to either usual care or a 3-month period of auto-titrating CPAP. The primary hypothesis is that nocturnal CPAP will improve neuropsychological functioning more than usual care alone. The secondary hypothesis is that the magnitude of improvement of neuropsychological function will be predicted by the severity of baseline sleepiness measures, sleep fragmentation and sleep apnoea. Neuropsychological tests and full polysomnography will be performed at baseline and 3 months with interim measures of sleepiness and symptoms of autonomic dysfunction measured weekly. Spirometry will be performed monthly. Neuropsychological tests will be administered by blinded assessors. Recruitment commenced in July 2009. The results of

  1. Unsteady flow characteristics through a human nasal airway.

    Science.gov (United States)

    Lee, Jong-Hoon; Na, Yang; Kim, Sung-Kyun; Chung, Seung-Kyu

    2010-07-31

    Time-dependent characteristics of the flow in a human nasal airway constructed from the CT image of a healthy volunteer were investigated using a computational fluid dynamics (CFD) technique. To capture the time-varying nature of the flow as well as pressure and temperature fields, the large eddy simulation (LES) technique instead of the RANS (Reynolds Averaged Navier-Stokes) approach was adopted. To make the present analysis more relevant to a real human breathing cycle, the flow was designed to be induced by the pressure difference and the time-varying pressure at the end of trachea was described to reproduce the flow rate data from the measurement. Comparison of the present results with those of typical steady simulations showed that the difference in flow characteristics is magnified in the expiration phase. This fact may suggest that the inertial effect associated with unsteady flow is more important during the expiration period. Also, the fact that the distribution of the flow rate in a given cross-section of the airway changes significantly with time implies the importance of unsteady data for clinical decision. The wall shear stress was found to have relatively high values at the locations near nasopharynx and larynx but the magnitude changes with time during the whole respiratory cycle. Analysis of the temperature field showed that most of the temperature change occurs in the nasal cavity when the air is incoming and thus, the nasal cavity acts as a very efficient heat exchanger during an inspiration period. Copyright 2010 Elsevier B.V. All rights reserved.

  2. Upper airway muscles awake and asleep.

    Science.gov (United States)

    Sériès, Frédéric

    2002-06-01

    Upper airway (UA) structures are involved in different respiratory and non-respiratory tasks. The coordination of agonist and antagonist UA dilators is responsible for their mechanical function and their ability to maintain UA patency throughout the respiratory cycle. The activity of these muscles is linked with central respiratory activity but also depends on UA pressure changes and is greatly influenced by sleep. UA muscles are involved in determining UA resistance and stability (i.e. closing pressure), and the effect of sleep on these variables may be accounted for by its effect on tonic and phasic skeletal muscle activities. The mechanical effects of UA dilator contraction also depend on their physiological properties (capacity to generate tension in vitro, activity of the anaerobic enzymatic pathway, histo-chemical characteristics that may differ between subjects who may or may not have sleep-related obstructive breathing disorders). These characteristics may represent an adaptive process to an increased resistive loading of these muscles. The apparent discrepancy between the occurrence of UA closure and an increased capacity to generate tension in sleep apnea patients may be due to a reduction in the effectiveness of UA muscle contraction in these patients; such an increase in tissue stiffness could be accounted for by peri-muscular tissue characteristics. Therefore, understanding of UA muscle physiological characteristics should take into account its capacity for force production and its mechanical coupling with other UA tissues. Important research goals for the future will be to integrate these issues with other physiological features of the disease, such as UA size and dimension, histological characteristics of UA tissues and the effect of sleep on muscle function. Such integration will better inform understanding of the role of pharyngeal UA muscles in the pathophysiology of the sleep apnea/hypopnea syndrome.

  3. Computationally efficient analysis of particle transport and deposition in a human whole-lung-airway model. Part I: Theory and model validation.

    Science.gov (United States)

    Kolanjiyil, Arun V; Kleinstreuer, Clement

    2016-12-01

    Computational predictions of aerosol transport and deposition in the human respiratory tract can assist in evaluating detrimental or therapeutic health effects when inhaling toxic particles or administering drugs. However, the sheer complexity of the human lung, featuring a total of 16 million tubular airways, prohibits detailed computer simulations of the fluid-particle dynamics for the entire respiratory system. Thus, in order to obtain useful and efficient particle deposition results, an alternative modeling approach is necessary where the whole-lung geometry is approximated and physiological boundary conditions are implemented to simulate breathing. In Part I, the present new whole-lung-airway model (WLAM) represents the actual lung geometry via a basic 3-D mouth-to-trachea configuration while all subsequent airways are lumped together, i.e., reduced to an exponentially expanding 1-D conduit. The diameter for each generation of the 1-D extension can be obtained on a subject-specific basis from the calculated total volume which represents each generation of the individual. The alveolar volume was added based on the approximate number of alveoli per generation. A wall-displacement boundary condition was applied at the bottom surface of the first-generation WLAM, so that any breathing pattern due to the negative alveolar pressure can be reproduced. Specifically, different inhalation/exhalation scenarios (rest, exercise, etc.) were implemented by controlling the wall/mesh displacements to simulate realistic breathing cycles in the WLAM. Total and regional particle deposition results agree with experimental lung deposition results. The outcomes provide critical insight to and quantitative results of aerosol deposition in human whole-lung airways with modest computational resources. Hence, the WLAM can be used in analyzing human exposure to toxic particulate matter or it can assist in estimating pharmacological effects of administered drug-aerosols. As a practical

  4. A clinical comparison of disposable airway devices | Strydom ...

    African Journals Online (AJOL)

    Cuff pressures were significantly higher in the Ambu™ and LMA Unique™ (p = 0.001). Maximum airway pressure attainable after 5 minutes was significantly higher in the Ambu™ (p = 0.036). Airway trauma as graded by visible blood on the device was low, and similar between groups (p = 0.237). Secretions were negligible ...

  5. Numerical investigation of inspiratory airflow in a realistic model of the human tracheobronchial airways and a comparison with experimental results.

    Science.gov (United States)

    Elcner, Jakub; Lizal, Frantisek; Jedelsky, Jan; Jicha, Miroslav; Chovancova, Michaela

    2016-04-01

    In this article, the results of numerical simulations using computational fluid dynamics (CFD) and a comparison with experiments performed with phase Doppler anemometry are presented. The simulations and experiments were conducted in a realistic model of the human airways, which comprised the throat, trachea and tracheobronchial tree up to the fourth generation. A full inspiration/expiration breathing cycle was used with tidal volumes 0.5 and 1 L, which correspond to a sedentary regime and deep breath, respectively. The length of the entire breathing cycle was 4 s, with inspiration and expiration each lasting 2 s. As a boundary condition for the CFD simulations, experimentally obtained flow rate distribution in 10 terminal airways was used with zero pressure resistance at the throat inlet. CCM+ CFD code (Adapco) was used with an SST k-ω low-Reynolds Number RANS model. The total number of polyhedral control volumes was 2.6 million with a time step of 0.001 s. Comparisons were made at several points in eight cross sections selected according to experiments in the trachea and the left and right bronchi. The results agree well with experiments involving the oscillation (temporal relocation) of flow structures in the majority of the cross sections and individual local positions. Velocity field simulation in several cross sections shows a very unstable flow field, which originates in the tracheal laryngeal jet and propagates far downstream with the formation of separation zones in both left and right airways. The RANS simulation agrees with the experiments in almost all the cross sections and shows unstable local flow structures and a quantitatively acceptable solution for the time-averaged flow field.

  6. What Causes Bad Breath?

    Science.gov (United States)

    ... Videos for Educators Search English Español What Causes Bad Breath? KidsHealth / For Teens / What Causes Bad Breath? Print en español ¿Qué es lo que provoca el mal aliento? Bad breath, or halitosis , can be a major problem, ...

  7. Physiological techniques for detecting expiratory flow limitation during tidal breathing

    Directory of Open Access Journals (Sweden)

    N.G. Koulouris

    2011-09-01

    Full Text Available Patients with severe chronic obstructive pulmonary disease (COPD often exhale along the same flow–volume curve during quiet breathing as they do during the forced expiratory vital capacity manoeuvre, and this has been taken as an indicator of expiratory flow limitation at rest (EFLT. Therefore, EFLT, namely attainment of maximal expiratory flow during tidal expiration, occurs when an increase in transpulmonary pressure causes no increase in expiratory flow. EFLT leads to small airway injury and promotes dynamic pulmonary hyperinflation, with concurrent dyspnoea and exercise limitation. In fact, EFLT occurs commonly in COPD patients (mainly in Global Initiative for Chronic Obstructive Lung Disease III and IV stage, in whom the latter symptoms are common, but is not exclusive to COPD, since it can also be detected in other pulmonary and nonpulmonary diseases like asthma, acute respiratory distress syndrome, heart failure and obesity, etc. The existing up to date physiological techniques of assessing EFLT are reviewed in the present work. Among the currently available techniques, the negative expiratory pressure has been validated in a wide variety of settings and disorders. Consequently, it should be regarded as a simple, noninvasive, practical and accurate new technique.

  8. Dimensions of the cleft nasal airway in adults: a comparison with subjects without cleft.

    Science.gov (United States)

    Hairfield, W M; Warren, D W

    1989-01-01

    The prevalence of mouthbreathing among individuals with cleft lip and palate is significantly higher than in the normal population. This has been attributed to nasal deformities that tend to reduce nasal airway size. The purpose of the present study was to determine how a heterogeneous adult group with cleft lip and palate differs in terms of nasal airway cross-sectional area from an adult group without cleft during the inspiratory and expiratory phases of breathing. The pressure-flow technique was used to estimate nasal airway size in 15 adults without cleft (15 years or older) and 37 adults with cleft lip, cleft palate, or both. Mean areas and standard deviations for subjects without cleft were 0.63 cm2 +/- 0.17 during inspiration and 0.56 cm2 +/- 0.14 during expiration. This difference is statistically significant (p less than 0.01). Mean areas and standard deviations for all subjects with cleft were 0.37 cm2 +/- 0.18 during inspiration and 0.40 cm2 +/- 0.20 during expiration. This difference is not statistically significant (p greater than 0.15). Twenty-two of the subjects with cleft had nasal areas considered to be impaired (below 0.40 cm2) as compared with only three of the subjects without cleft. A two factor analysis of variance (ANOVA) demonstrated that area changes during respiration are different for subjects with and without cleft (p less than 0.005), and that cleft nasal areas are smaller than noncleft areas for both phases of breathing (p less than 0.001). Inspiratory-expiratory differences between subjects with and without cleft are probably the result of developmental defects, reparative surgery or both.(ABSTRACT TRUNCATED AT 250 WORDS)

  9. Variability of breath condensate pH may contribute to the better understanding of non-allergic seasonal respiratory diseases

    Science.gov (United States)

    Kullmann, Tamás; Szipőcs, Annamária

    2017-09-01

    The seasonal variability of certain non-allergic respiratory diseases is not clearly understood. Analysis of the breath condensate, the liquid that can be collected by breathing into a cold tube, has been proposed to bring closer to the understanding of airway pathologies. It has been assumed, that (1) airway lining fluid was a stable body liquid and (2) the breath condensate samples were representative of the airway lining fluid. Research was focussed on the identification of biomarkers indicative of respiratory pathologies. Despite 30 years of extended investigations breath condensate analysis has not gained any clinical implementation so far. The pH of the condensate is the characteristic that can be determined with the highest reproducibility. The present paper shows, that contrary to the initial assumptions, breath condensate is not a representative of the airway lining fluid, and the airway lining fluid is not a stable body liquid. Condensate pH shows baseline variability and it is influenced by drinking and by the ambient temperature. The changes in condensate pH are linked to changes in airway lining fluid pH. The variability of airway lining fluid pH may explain seasonal incidence of certain non-allergic respiratory diseases such as the catching of a common cold and the increased incidence of COPD exacerbations and exercise-induced bronchoconstriction in cold periods.

  10. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Make a Charitable Gift Our Corporate Supporters Workplace Engagement DONATE YOUR PROPERTY eCards for a Cure About ... airway walls. See how different airway clearance techniques work to help you clear the thick, sticky mucus ...

  11. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... today. ANNUAL FUND Become a Corporate Supporter Cause Marketing Make a Charitable Gift Our Corporate Supporters Workplace ... Clearance Airway Clearance Techniques (ACTs) There are different ways to clear your airways. Most are easy to ...

  12. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... ACTs involve coughing or huffing . Many of them use percussion (clapping) or vibration to loosen mucus from airway walls. See how different airway clearance techniques work to help you clear the thick, sticky mucus ...

  13. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... D Structure Consortium CFTR Folding Consortium Epithelial Stem Cell Consortium Mucociliary Clearance Consortium SUCCESS WITH THERAPIES RESEARCH ... clapping) or vibration to loosen mucus from airway walls. See how different airway clearance techniques work to ...

  14. Effects of tidal volume on work of breathing during lung-protective ventilation in patients with acute lung injury and acute respiratory distress syndrome.

    Science.gov (United States)

    Kallet, Richard H; Campbell, Andre R; Dicker, Rochelle A; Katz, Jeffrey A; Mackersie, Robert C

    2006-01-01

    To assess the effects of step-changes in tidal volume on work of breathing during lung-protective ventilation in patients with acute lung injury (ALI) or the acute respiratory distress syndrome (ARDS). Prospective, nonconsecutive patients with ALI/ARDS. Adult surgical, trauma, and medical intensive care units at a major inner-city, university-affiliated hospital. Ten patients with ALI/ARDS managed clinically with lung-protective ventilation. Five patients were ventilated at a progressively smaller tidal volume in 1 mL/kg steps between 8 and 5 mL/kg; five other patients were ventilated at a progressively larger tidal volume from 5 to 8 mL/kg. The volume mode was used with a flow rate of 75 L/min. Minute ventilation was maintained constant at each tidal volume setting. Afterward, patients were placed on continuous positive airway pressure for 1-2 mins to measure their spontaneous tidal volume. Work of breathing and other variables were measured with a pulmonary mechanics monitor (Bicore CP-100). Work of breathing progressively increased (0.86 +/- 0.32, 1.05 +/- 0.40, 1.22 +/- 0.36, and 1.57 +/- 0.43 J/L) at a tidal volume of 8, 7, 6, and 5 mL/kg, respectively. In nine of ten patients there was a strong negative correlation between work of breathing and the ventilator-to-patient tidal volume difference (R = -.75 to -.998). : The ventilator-delivered tidal volume exerts an independent influence on work of breathing during lung-protective ventilation in patients with ALI/ARDS. Patient work of breathing is inversely related to the difference between the ventilator-delivered tidal volume and patient-generated tidal volume during a brief trial of unassisted breathing.

  15. A multicentre randomised controlled trial and economic evaluation of continuous positive airway pressure for the treatment of obstructive sleep apnoea syndrome in older people: PREDICT.

    Science.gov (United States)

    McMillan, Alison; Bratton, Daniel J; Faria, Rita; Laskawiec-Szkonter, Magda; Griffin, Susan; Davies, Robert J; Nunn, Andrew J; Stradling, John R; Riha, Renata L; Morrell, Mary J

    2015-06-01

    The therapeutic and economic benefits of continuous positive airway pressure (CPAP) for the treatment of obstructive sleep apnoea syndrome (OSAS) have been established in middle-aged people. In older people there is a lack of evidence. To determine the clinical efficacy of CPAP in older people with OSAS and to establish its cost-effectiveness. A randomised, parallel, investigator-blinded multicentre trial with within-trial and model-based cost-effectiveness analysis. Two hundred and seventy-eight patients, aged ≥ 65 years with newly diagnosed OSAS [defined as oxygen desaturation index at ≥ 4% desaturation threshold level for > 7.5 events/hour and Epworth Sleepiness Scale (ESS) score of ≥ 9] recruited from 14 hospital-based sleep services across the UK. CPAP with best supportive care (BSC) or BSC alone. Autotitrating CPAP was initiated using standard clinical practice. BSC was structured advice on minimising sleepiness. Subjective sleepiness at 3 months, as measured by the ESS (ESS mean score: months 3 and 4) and cost-effectiveness over 12 months, as measured in quality-adjusted life-years (QALYs) calculated using the European Quality of Life-5 Dimensions (EQ-5D) and health-care resource use, information on which was collected monthly from patient diaries. Subjective sleepiness at 12 months (ESS mean score: months 10, 11 and 12) and objective sleepiness, disease-specific and generic quality of life, mood, functionality, nocturia, mobility, accidents, cognitive function, cardiovascular risk factors and events at 3 and 12 months. Two hundred and seventy-eight patients were randomised to CPAP (n = 140) or BSC (n = 138) over 27 months and 231 (83%) patients completed the trial. Baseline ESS score was similar in both groups [mean (standard deviation; SD) CPAP 11.5 (3.3), BSC 11.4 (4.2)]; groups were well balanced for other characteristics. The mean (SD) in ESS score at 3 months was -3.8 (0.4) in the CPAP group and -1.6 (0.3) in the BSC group. The

  16. Heated, Humidified High-Flow Nasal Cannula vs Nasal Continuous Positive Airway Pressure for Respiratory Distress Syndrome of Prematurity: A Randomized Clinical Noninferiority Trial.

    Science.gov (United States)

    Lavizzari, Anna; Colnaghi, Mariarosa; Ciuffini, Francesca; Veneroni, Chiara; Musumeci, Stefano; Cortinovis, Ivan; Mosca, Fabio

    2016-08-08

    Heated, humidified high-flow nasal cannula (HHHFNC) has gained increasing popularity as respiratory support for newborn infants thanks to ease of use and improved patient comfort. However, its role as primary therapy for respiratory distress syndrome (RDS) of prematurity needs to be further elucidated by large, randomized clinical trials. To determine whether HHHFNC provides respiratory support noninferior to nasal continuous positive airway pressure (nCPAP) or bilevel nCPAP (BiPAP) as a primary approach to RDS in infants older than 28 weeks' gestational age (GA). An unblinded, monocentric, randomized clinical noninferiority trial at a tertiary neonatal intensive care unit. Inborn infants at 29 weeks 0 days to 36 weeks 6 days of GA were eligible if presenting with mild to moderate RDS requiring noninvasive respiratory support. Criteria for starting noninvasive respiratory support were a Silverman score of 5 or higher or a fraction of inspired oxygen higher than 0.3 for a target saturation of peripheral oxygen of 88% to 93%. Infants were ineligible if they had major congenital anomalies or severe RDS requiring early intubation. Infants were enrolled between January 5, 2012, and June 28, 2014. Randomization to either HHHFNC at 4 to 6 L/min or nCPAP/BiPAP at 4 to 6 cm H2O. Need for mechanical ventilation within 72 hours from the beginning of respiratory support. The absolute risk difference in the primary outcome and its 95% confidence interval were calculated to determine noninferiority (noninferiority margin, 10%). An intention-to-treat analysis was performed. A total of 316 infants were enrolled in the study: 158 in the HHHFNC group (mean [SD] GA, 33.1 [1.9] weeks; 52.5% female) and 158 in the nCPAP/BiPAP group (mean [SD] GA, 33.0 [2.1] weeks; 47.5% female). The use of HHHFNC was noninferior to nCPAP with regard to the primary outcome: failure occurred in 10.8% vs 9.5% of infants, respectively (95% CI of risk difference, -6.0% to 8.6% [within the noninferiority

  17. A new method of maintaining airway during nasotracheal intubation--the hand mask technique.

    Science.gov (United States)

    Wu, R S; Wong, D S; Chung, P C; Tan, P P

    1993-09-01

    The efficacy of a new method (The hand mask technique) for airway maintenance during nasotracheal intubation was evaluated in our randomized crossover study. Sixty, age less than 50, ASA physical status class I-II patients undergoing surgery for the extremities with informed consent were randomly chosen for the study. Pulse oximeter, capnometer, EKG, blood pressure monitor and a peripheral nerve stimulator were attached to the patients before induction for continuous monitoring. An arterial cannula was inserted for intermittent blood gas sampling. After baseline room air blood gas data had been obtained from the spontaneously breathing patients, a flow rate of 6L/min pure oxygen was applied through a loosely fitted face mask and a semi-closed anesthesia breathing circuit for a period of 5 minutes. An arterial blood sample was drawn and the patients were put under general anesthesia with full muscle relaxation thereafter. Patients were then randomly assigned into two groups according to the ventilation technique used. Group A patients (n = 30) were manually ventilated first through a face mask for ten minutes and then the hand mask technique for another ten minutes. Blood gas data was sampled and heart rate, blood pressure, peak inspiratory airway pressure and end tidal CO2 were recorded immediately after each ventilation technique. For patients in Group B (n = 30), the sequence of the two ventilation technique were reversed. The results showed significant increases in PaO2 after artificial ventilation in both groups (No significant difference in results between the two groups) and less incidence of nasal bleeding in Group A.(ABSTRACT TRUNCATED AT 250 WORDS)

  18. Mechanisms of mechanical strain memory in airway smooth muscle.

    Science.gov (United States)

    Kim, Hak Rim; Hai, Chi-Ming

    2005-10-01

    We evaluated the hypothesis that mechanical deformation of airway smooth muscle induces structural remodeling of airway smooth muscle cells, thereby modulating mechanical performance in subsequent contractions. This hypothesis implied that past experience of mechanical deformation was retained (or "memorized") as structural changes in airway smooth muscle cells, which modulated the cell's subsequent contractile responses. We termed this phenomenon mechanical strain memory. Preshortening has been found to induce attenuation of both force and isotonic shortening velocity in cholinergic receptor-activated airway smooth muscle. Rapid stretching of cholinergic receptor-activated airway smooth muscle from an initial length to a final length resulted in post-stretch force and myosin light chain phosphorylation that correlated significantly with initial length. Thus post-stretch muscle strips appeared to retain memory of the initial length prior to rapid stretch (mechanical strain memory). Cytoskeletal recruitment of actin- and integrin-binding proteins and Erk 1/2 MAPK appeared to be important mechanisms of mechanical strain memory. Sinusoidal length oscillation led to force attenuation during oscillation and in subsequent contractions in intact airway smooth muscle, and p38 MAPK appeared to be an important mechanism. In contrast, application of local mechanical strain to cultured airway smooth muscle cells induced local actin polymerization and cytoskeletal stiffening. It is conceivable that deep inspiration-induced bronchoprotection may be a manifestation of mechanical strain memory such that mechanical deformation from past breathing cycles modulated the mechanical performance of airway smooth muscle in subsequent cycles in a continuous and dynamic manner.

  19. Lung and chest wall impedances in the dog in normal range of breathing: effects of pulmonary edema.

    Science.gov (United States)

    Barnas, G M; Stamenović, D; Lutchen, K R

    1992-09-01

    We evaluated the effect of pulmonary edema on the frequency (f) and tidal volume (VT) dependences of respiratory system mechanical properties in the normal ranges of breathing. We measured resistance and elastance of the lungs (RL and EL) and chest wall of four anesthetized-paralyzed dogs during sinusoidal volume oscillations at the trachea (50-300 ml, 0.2-2 Hz), delivered at a constant mean airway pressure. Measurements were made before and after severe pulmonary edema was produced by injection of 0.06 ml/kg oleic acid into the right atrium. Chest wall properties were not changed by the injection. Before oleic acid, EL increased slightly with increasing f in each dog but was independent of VT. RL decreased slightly and was independent of VT from 0.2 to 0.4 Hz, but above 0.4 Hz it tended to increase with increasing flow, presumably due to the airway contribution. After oleic acid injection, EL and RL increased greatly. Large negative dependences of EL on VT and of RL on f were also evident, so that EL and RL after oleic acid changed two- and fivefold, respectively, within the ranges of f and VT studied. We conclude that severe pulmonary edema changes lung properties so as to make behavior VT dependent (i.e., nonlinear) and very frequency dependent in the normal range of breathing.

  20. Airway distensibility in Chronic Obstructive Airway Disease

    DEFF Research Database (Denmark)

    Winkler Wille, Mathilde Marie; Pedersen, Jesper Holst; Dirksen, Asger

    2013-01-01

    Rationale – Chronic Obstructive Pulmonary Disease (COPD) is a combination of chronic bronchitis and emphysema, which both may lead to airway obstruction. Under normal circumstances, airway dimensions vary as a function of inspiration level. We aim to study the influence of COPD and emphysema......-20% (mild), 20%-30% (moderate) or >30% (severe). Spirometry was performed annually and participants were divided into severity groups according to the Global Initiative for Chronic Obstructive Lung Disease (GOLD). Data were analysed in a mixed effects regression model with log(airway lumen diameter...... and emphysema, respectively. Conclusions – Airway distensibility decreases significantly with increasing severity of both GOLD status and emphysema, indicating that in COPD the dynamic change in airway calibre during respiration is compromised. Chronic bronchitis and emphysema appear to be interacting...

  1. Increased respiratory neural drive and work of breathing in exercise-induced laryngeal obstruction.

    Science.gov (United States)

    Walsted, Emil S; Faisal, Azmy; Jolley, Caroline J; Swanton, Laura L; Pavitt, Matthew J; Luo, Yuan-Ming; Backer, Vibeke; Polkey, Michael I; Hull, James H

    2018-02-01

    Exercise-induced laryngeal obstruction (EILO), a phenomenon in which the larynx closes inappropriately during physical activity, is a prevalent cause of exertional dyspnea in young individuals. The physiological ventilatory impact of EILO and its relationship to dyspnea are poorly understood. The objective of this study was to evaluate exercise-related changes in laryngeal aperture on ventilation, pulmonary mechanics, and respiratory neural drive. We prospectively evaluated 12 subjects (6 with EILO and 6 healthy age- and gender-matched controls). Subjects underwent baseline spirometry and a symptom-limited incremental exercise test with simultaneous and synchronized recording of endoscopic video and gastric, esophageal, and transdiaphragmatic pressures, diaphragm electromyography, and respiratory airflow. The EILO and control groups had similar peak work rates and minute ventilation (V̇e) (work rate: 227 ± 35 vs. 237 ± 35 W; V̇e: 103 ± 20 vs. 98 ± 23 l/min; P > 0.05). At submaximal work rates (140-240 W), subjects with EILO demonstrated increased work of breathing ( P respiratory neural drive ( P respiratory mechanics and diaphragm electromyography with endoscopic video, we demonstrate, for the first time, increased work of breathing and respiratory neural drive in association with the development of EILO. Future detailed investigations are now needed to understand the role of upper airway closure in causing exertional dyspnea and exercise limitation. NEW & NOTEWORTHY Exercise-induced laryngeal obstruction is a prevalent cause of exertional dyspnea in young individuals; yet, how laryngeal closure affects breathing is unknown. In this study we synchronized endoscopic video with respiratory physiological measurements, thus providing the first detailed commensurate assessment of respiratory mechanics and neural drive in relation to laryngeal closure. Laryngeal closure was associated with increased work of breathing and respiratory neural drive preceded by an

  2. A fibre-optic oxygen sensor for monitoring human breathing

    International Nuclear Information System (INIS)

    Chen, Rongsheng; Formenti, Federico; Hahn, Clive E W; Farmery, Andrew D; Obeid, Andy

    2013-01-01

    The development and construction of a tapered-tip fibre-optic fluorescence based oxygen sensor is described. The sensor is suitable for fast and real-time monitoring of human breathing. The sensitivity and response time of the oxygen sensor were evaluated in vitro with a gas pressure chamber system, where oxygen partial pressure was rapidly changed between 5 and 15 kPa, and then in vivo in five healthy adult participants who synchronized their breathing to a metronome set at 10, 20, 30, 40, 50, and 60 breaths min –1 . A Datex Ultima medical gas analyser was used to monitor breathing rate as a comparator. The sensor's response time in vitro was less than 150 ms, which allows accurate continuous measurement of inspired and expired oxygen pressure. Measurements of breathing rate by means of our oxygen sensor and of the Datex Ultima were in strong agreement. The results demonstrate that the device can reliably resolve breathing rates up to 60 breaths min –1 , and that it is a suitable cost-effective alternative for monitoring breathing rates and end-tidal oxygen partial pressure in the clinical setting. The rapid response time of the sensor may allow its use for monitoring rapid breathing rates as occur in children and the newborn. (note)

  3. Bronchoscopic lung-volume reduction with Exhale airway stents for emphysema (EASE trial) : randomised, sham-controlled, multicentre trial

    NARCIS (Netherlands)

    Shah, P. L.; Slebos, D-J; Cardoso, P. F. G.; Cetti, E.; Voelker, K.; Levine, B.; Russell, M. E.; Goldin, J.; Brown, M.; Cooper, J. D.; Sybrecht, G. W.

    2011-01-01

    Background Airway bypass is a bronchoscopic lung-volume reduction procedure for emphysema whereby transbronchial passages into the lung are created to release trapped air, supported with paclitaxel-coated stents to ease the mechanics of breathing. The aim of the EASE (Exhale airway stents for

  4. Cardiorespiratory interactions during resistive load breathing.

    Science.gov (United States)

    Calabrese, P; Perrault, H; Dinh, T P; Eberhard, A; Benchetrit, G

    2000-12-01

    The addition to the respiratory system of a resistive load results in breathing pattern changes and in negative intrathoracic pressure increases. The aim of this study was to use resistive load breathing as a stimulus to the cardiorespiratory interaction and to examine the extent of the changes in heart rate variability (HRV) and respiratory sinus arrhythmia (RSA) in relation to the breathing pattern changes. HRV and RSA were studied in seven healthy subjects where four resistive loads were applied in a random order during the breath and 8-min recording made in each condition. The HRV spectral power components were computed from the R-R interval sequences, and the RSA amplitude and phase were computed from the sinusoid fitting the instantaneous heart rate within each breath. Adding resistive loads resulted in 1) increasing respiratory period, 2) unchanging heart rate, and 3) increasing HRV and changing RSA characteristics. HRV and RSA characteristics are linearly correlated to the respiratory period. These modifications appear to be linked to load-induced changes in the respiratory period in each individual, because HRV and RSA characteristics are similar at a respiratory period obtained either by loading or by imposed frequency breathing. The present results are discussed with regard to the importance of the breathing cycle duration in these cardiorespiratory interactions, suggesting that these interactions may depend on the time necessary for activation and dissipation of neurotransmitters involved in RSA.

  5. The patient inflating valve in anaesthesia and resuscitation breathing systems.

    Science.gov (United States)

    Fenton, P M; Bell, G

    2013-03-01

    Patient inflating valves combined with self-inflating bags are known to all anaesthetists as resuscitation devices and are familiar as components of draw-over anaesthesia systems. Their variants are also commonplace in transfer and home ventilators. However, the many variations in structure and function have led to difficulties in their optimal use, definition and classification. After reviewing the relevant literature, we defined a patient inflating valve as a one-way valve that closes an exit port to enable lung inflation, also permitting exhalation and spontaneous breathing, the actions being automatic. We present a new classification based on the mechanism of valve opening/closure; namely elastic recoil of a flexible flap/diaphragm, sliding spindle opened by a spring/magnet or a hollow balloon collapsed by external pressure. The evolution of these valves has been driven by the difficulties documented in critical incidents, which we have used along with information from modern International Organization for Standardization standards to identify 13 ideal properties, the top six of which are non-jamming, automatic, no bypass effect, no rebreathing or air entry at patient end, low resistance, robust and easy to service. The Ambu and the Laerdal valves have remained popular due to their simplicity and reliability. Two new alternatives, the Fenton and Diamedica valves, offer the benefits of location away from the patient while retaining a small functional dead space. They also offer the potential for greater use of hybrid continuous flow/draw-over systems that can operate close to atmospheric pressure. The reliable application of positive end-expiratory pressure/continuous positive airway pressure remains a challenge.

  6. Practice parameters for the surgical modifications of the upper airway for obstructive sleep apnea in adults.

    Science.gov (United States)

    Aurora, R Nisha; Casey, Kenneth R; Kristo, David; Auerbach, Sanford; Bista, Sabin R; Chowdhuri, Susmita; Karippot, Anoop; Lamm, Carin; Ramar, Kannan; Zak, Rochelle; Morgenthaler, Timothy I

    2010-10-01

    appliances, which are more often appropriate in mild and moderate OSA patients, have been considered and found ineffective or undesirable (Option). UPPP as a sole procedure, with or without tonsillectomy, does not reliably normalize the AHI when treating moderate to severe obstructive sleep apnea syndrome. Therefore, patients with severe OSA should initially be offered positive airway pressure therapy, while those with moderate OSA should initially be offered either PAP therapy or oral appliances (Option). Use of multi-level or stepwise surgery (MLS), as a combined procedure or as stepwise multiple operations, is acceptable in patients with narrowing of multiple sites in the upper airway, particularly if they have failed UPPP as a sole treatment (Option). LAUP is not routinely recommended as a treatment for obstructive sleep apnea syndrome (Standard). RFA can be considered as a treatment in patients with mild to moderate obstructive sleep apnea who cannot tolerate or who are unwilling to adhere to positive airway pressure therapy, or in whom oral appliances have been considered and found ineffective or undesirable (Option). Palatal implants may be effective in some patients with mild obstructive sleep apnea who cannot tolerate or who are unwilling to adhere to positive airway pressure therapy, or in whom oral appliances have been considered and found ineffective or undesirable (Option). Postoperatively, after an appropriate period of healing, patients should undergo follow-up evaluation including an objective measure of the presence and severity of sleep-disordered breathing and oxygen saturation, as well as clinical assessment for residual symptoms. Additionally, patients should be followed over time to detect the recurrence of disease (Standard). While there has been significant progress made in surgical techniques for the treatment of OSA, there is a lack of rigorous data evaluating surgical modifications of the upper airway. Systematic and methodical investigations are

  7. Management of Sleep Disordered Breathing in Patients with Heart Failure.

    Science.gov (United States)

    Oates, Connor P; Ananthram, Manjula; Gottlieb, Stephen S

    2018-04-03

    This paper reviews treatment options for sleep disordered breathing (SDB) in patients with heart failure. We sought to identify therapies for SDB with the best evidence for long-term use in patients with heart failure and to minimize uncertainties in clinical practice by examining frequently discussed questions: what is the role of continuous positive airway pressure (CPAP) in patients with heart failure? Is adaptive servo-ventilation (ASV) safe in patients with heart failure? To what extent is SDB a modifiable risk factor? Consistent evidence has demonstrated that the development of SDB in patients with heart failure is a poor prognostic indicator and a risk factor for cardiovascular mortality. However, despite numerous available interventions for obstructive sleep apnea and central sleep apnea, it remains unclear what effect these therapies have on patients with heart failure. To date, all major randomized clinical trials have failed to demonstrate a survival benefit with SDB therapy and one major study investigating the use of adaptive servo-ventilation demonstrated harm. Significant questions persist regarding the management of SDB in patients with heart failure. Until appropriately powered trials identify a treatment modality that increases cardiovascular survival in patients with SDB and heart failure, a patient's heart failure management should remain the priority of medical care.

  8. A prospective crossover comparison of neurally adjusted ventilatory assist and pressure-support ventilation in a pediatric and neonatal intensive care unit population.

    LENUS (Irish Health Repository)

    Breatnach, Cormac

    2012-02-01

    OBJECTIVE: To compare neurally adjusted ventilatory assist ventilation with pressure-support ventilation. DESIGN: Prospective, crossover comparison study. SETTING: Tertiary care pediatric and neonatal intensive care unit. PATIENTS: Sixteen ventilated infants and children: mean age = 9.7 months (range = 2 days-4 yrs) and mean weight = 6.2 kg (range = 2.4-13.7kg). INTERVENTIONS: A modified nasogastric tube was inserted and correct positioning was confirmed. Patients were ventilated in pressure-support mode with a pneumatic trigger for a 30-min period and then in neurally adjusted ventilatory assist mode for up to 4 hrs. MEASUREMENTS AND MAIN RESULTS: Data collected for comparison included activating trigger (neural vs. pneumatic), peak and mean airway pressures, expired minute and tidal volumes, heart rate, respiratory rate, pulse oximetry, end-tidal CO2 and arterial blood gases. Synchrony was improved in neurally adjusted ventilatory assist mode with 65% (+\\/-21%) of breaths triggered neurally vs. 35% pneumatically (p < .001) and 85% (+\\/-8%) of breaths cycled-off neurally vs. 15% pneumatically (p = .0001). The peak airway pressure in neurally adjusted ventilatory assist mode was significantly lower than in pressure-support mode with a 28% decrease in pressure after 30 mins (p = .003) and 32% decrease after 3 hrs (p < .001). Mean airway pressure was reduced by 11% at 30 mins (p = .13) and 9% at 3 hrs (p = .31) in neurally adjusted ventilatory assist mode although this did not reach statistical significance. Patient hemodynamics and gas exchange remained stable for the study period. No adverse patient events or device effects were noted. CONCLUSIONS: In a neonatal and pediatric intensive care unit population, ventilation in neurally adjusted ventilatory assist mode was associated with improved patient-ventilator synchrony and lower peak airway pressure when compared with pressure-support ventilation with a pneumatic trigger. Ventilating patients in this new mode

  9. Exploring effects of therapeutic massage and patient teaching in the practice of diaphragmatic breathing on blood pressure, stress, and anxiety in hypertensive African-American women: an intervention study.

    Science.gov (United States)

    Jefferson, Lenetra L

    2010-07-01

    The problem of hypertension among African-Americans is one of the major areas of health disparities. The American Heart Association (2009) noted that the prevalence of hypertension among African-Americans is perhaps among the highest in the world and this is particularly so among African-American women (44.0%). The purpose of this study was to determine how therapeutic chair massage and patient teaching in diaphragmatic breathing affected African-American women's blood pressure, stress, and anxiety levels over one week or six weeks time periods. A Modified Stress, Coping, and Adaptation Model (Roy, 1976; Lazarus, 1966), Descriptives, T-tests, Pearson Product Moment Correlations, Multivariate analysis of variance (MANOVA), and Multivariate analysis of variance with covariate (MANCOVA) were used. Descriptive statistics indicated a significance for decreased systolic blood pressure levels for the one week post massage intervention measurement with p = .01, diastolic blood pressure level significance for the same group p = .02, significance for this group's State Trait Anxiety Inventory (STAI) Y2 Scale score p = .01, and Roy's Largest Root p = .03.

  10. Sports-related lung injury during breath-hold diving

    Directory of Open Access Journals (Sweden)

    Tanja Mijacika

    2016-12-01

    Full Text Available The number of people practising recreational breath-hold diving is constantly growing, thereby increasing the need for knowledge of the acute and chronic effects such a sport could have on the health of participants. Breath-hold diving is potentially dangerous, mainly because of associated extreme environmental factors such as increased hydrostatic pressure, hypoxia, hypercapnia, hypothermia and strenuous exercise. In this article we focus on the effects of breath-hold diving on pulmonary function. Respiratory symptoms have been reported in almost 25% of breath-hold divers after repetitive diving sessions. Acutely, repetitive breath-hold diving may result in increased transpulmonary capillary pressure, leading to noncardiogenic oedema and/or alveolar haemorrhage. Furthermore, during a breath-hold dive, the chest and lungs are compressed by the increasing pressure of water. Rapid changes in lung air volume during descent or ascent can result in a lung injury known as pulmonary barotrauma. Factors that may influence individual susceptibility to breath-hold diving-induced lung injury range from underlying pulmonary or cardiac dysfunction to genetic predisposition. According to the available data, breath-holding does not result in chronic lung injury. However, studies of large populations of breath-hold divers are necessary to firmly exclude long-term lung damage.

  11. Mucociliary clearance, airway inflammation and nasal symptoms in urban motorcyclists

    Directory of Open Access Journals (Sweden)

    Tereza C.S. Brant

    2014-01-01

    Full Text Available OBJECTIVES: There is evidence that outdoor workers exposed to high levels of air pollution exhibit airway inflammation and increased airway symptoms. We hypothesized that these workers would experience increased airway symptoms and decreased nasal mucociliary clearance associated with their exposure to air pollution. METHODS: In total, 25 non-smoking commercial motorcyclists, aged 18-44 years, were included in this study. These drivers work 8-12 hours per day, 5 days per week, driving on urban streets. Nasal mucociliary clearance was measured by the saccharine transit test; airway acidification was measured by assessing the pH of exhaled breath condensate; and airway symptoms were measured by the Sino-nasal Outcome Test-20 questionnaire. To assess personal air pollution exposure, the subjects used a passive-diffusion nitrogen dioxide (NO2 concentration-monitoring system during the 14 days before each assessment. The associations between NO2 and the airway outcomes were analyzed using the Mann-Whitney test and the Chi-Square test. Clinicaltrials.gov: NCT01976039. RESULTS: Compared with clearance in healthy adult males, mucociliary clearance was decreased in 32% of the motorcyclists. Additionally, 64% of the motorcyclists had airway acidification and 92% experienced airway symptoms. The median personal NO2 exposure level was 75 mg/m3 for these subjects and a significant association was observed between NO2 and impaired mucociliary clearance (p = 0.036. CONCLUSION: Non-smoking commercial motorcyclists exhibit increased airway symptoms and airway acidification as well as decreased nasal mucociliary clearance, all of which are significantly associated with the amount of exposure to air pollution.

  12. The usefulness of dynamic MRI for diagnosing and assessing sleep breathing disorder

    International Nuclear Information System (INIS)

    Moriwaki, Hiroto; Uchida, Akira; Chiba, Sachiko; Moriyama, Hiroshi; Tokunaga, Masakazu

    2003-01-01

    Polysomnography is useful for assessing the severity of sleep breathing disorder, including obstructive sleep apnea hypopnea syndrome. The clinical condition is difficult to understand completely, however, based on the apnea hypopnea index (AHI) alone, however, and longitudinal change of shape in the upper airway must be clarified. Most diagnoses of obstructive sites in the upper airway were diagnosed statically, so we attempted to assess changes in upper airway shape using dynamic magnetic resonance imaging (MRI), emphasizing the movement of tongue and lower chin, to analyze the relationship between AHI. Subjects were 62 patients with sleep breathing disorder examined by nocturnal polysomnography and dynamic MRI, assessing the change of shape in the upper airway. We concluded that: the group whose rotation angle of the tongue exceeded 6 deg and that the group whose distance of lower chin movement was longer during sleep than while awake were severe cases. (author)

  13. The usefulness of dynamic MRI for diagnosing and assessing sleep breathing disorder

    Energy Technology Data Exchange (ETDEWEB)

    Moriwaki, Hiroto; Uchida, Akira; Chiba, Sachiko; Moriyama, Hiroshi [Jikei Univ., Tokyo (Japan). School of Medicine; Chiba, Shintarou; Yagi, Asako; Ohta, Masaji [Ohta General Hospital, Kawasaki, Kanagawa (Japan); Tokunaga, Masakazu [Kanagawa Prefecture Midwives and Nurses Training School (Japan). Hospital

    2003-04-01

    Polysomnography is useful for assessing the severity of sleep breathing disorder, including obstructive sleep apnea hypopnea syndrome. The clinical condition is difficult to understand completely, however, based on the apnea hypopnea index (AHI) alone, however, and longitudinal change of shape in the upper airway must be clarified. Most diagnoses of obstructive sites in the upper airway were diagnosed statically, so we attempted to assess changes in upper airway shape using dynamic magnetic resonance imaging (MRI), emphasizing the movement of tongue and lower chin, to analyze the relationship between AHI. Subjects were 62 patients with sleep breathing disorder examined by nocturnal polysomnography and dynamic MRI, assessing the change of shape in the upper airway. We concluded that: the group whose rotation angle of the tongue exceeded 6 deg and that the group whose distance of lower chin movement was longer during sleep than while awake were severe cases. (author)

  14. Lung hyperinflation stimulates the release of inflammatory mediators in spontaneously breathing subjects

    Directory of Open Access Journals (Sweden)

    L.M.S. Malbouisson

    2010-02-01

    Full Text Available Lung hyperinflation up to vital capacity is used to re-expand collapsed lung areas and to improve gas exchange during general anesthesia. However, it may induce inflammation in normal lungs. The objective of this study was to evaluate the effects of a lung hyperinflation maneuver (LHM on plasma cytokine release in 10 healthy subjects (age: 26.1 ± 1.2 years, BMI: 23.8 ± 3.6 kg/m². LHM was performed applying continuous positive airway pressure (CPAP with a face mask, increased by 3-cmH2O steps up to 20 cmH2O every 5 breaths. At CPAP 20 cmH2O, an inspiratory pressure of 20 cmH2O above CPAP was applied, reaching an airway pressure of 40 cmH2O for 10 breaths. CPAP was then decreased stepwise. Blood samples were collected before and 2 and 12 h after LHM. TNF-α, IL-1β, IL-6, IL-8, IL-10, and IL-12 were measured by flow cytometry. Lung hyperinflation significantly increased (P < 0.05 all measured cytokines (TNF-α: 1.2 ± 3.8 vs 6.4 ± 8.6 pg/mL; IL-1β: 4.9 ± 15.6 vs 22.4 ± 28.4 pg/mL; IL-6: 1.4 ± 3.3 vs 6.5 ± 5.6 pg/mL; IL-8: 13.2 ± 8.8 vs 33.4 ± 26.4 pg/mL; IL-10: 3.3 ± 3.3 vs 7.7 ± 6.5 pg/mL, and IL-12: 3.1 ± 7.9 vs 9 ± 11.4 pg/mL, which returned to basal levels 12 h later. A significant correlation was found between changes in pro- (IL-6 and anti-inflammatory (IL-10 cytokines (r = 0.89, P = 0.004. LHM-induced lung stretching was associated with an early inflammatory response in healthy spontaneously breathing subjects.

  15. EIT based pulsatile impedance monitoring during spontaneous breathing in cystic fibrosis.

    Science.gov (United States)

    Krueger-Ziolek, Sabine; Schullcke, Benjamin; Gong, Bo; Müller-Lisse, Ullrich; Moeller, Knut

    2017-06-01

    both subject groups were speculated to be caused by higher breathing efforts of the CF patients due to airway obstruction leading to higher intrathoracic pressures, and thus to greater changes in lung perfusion.

  16. Secondhand smoke exposure induces acutely airway acidification and oxidative stress.

    Science.gov (United States)

    Kostikas, Konstantinos; Minas, Markos; Nikolaou, Eftychia; Papaioannou, Andriana I; Liakos, Panagiotis; Gougoura, Sofia; Gourgoulianis, Konstantinos I; Dinas, Petros C; Metsios, Giorgos S; Jamurtas, Athanasios Z; Flouris, Andreas D; Koutedakis, Yiannis

    2013-02-01

    Previous studies have shown that secondhand smoke induces lung function impairment and increases proinflammatory cytokines. The aim of the present study was to evaluate the acute effects of secondhand smoke on airway acidification and airway oxidative stress in never-smokers. In a randomized controlled cross-over trial, 18 young healthy never-smokers were assessed at baseline and 0, 30, 60, 120, 180 and 240 min after one-hour secondhand smoke exposure at bar/restaurant levels. Exhaled NO and CO measurements, exhaled breath condensate collection (for pH, H(2)O(2) and NO(2)(-)/NO(3)(-) measurements) and spirometry were performed at all time-points. Secondhand smoke exposure induced increases in serum cotinine and exhaled CO that persisted until 240 min. Exhaled breath condensate pH decreased immediately after exposure (p secondhand smoke induced airway acidification and increased airway oxidative stress, accompanied by significant impairment of lung function. Despite the reversal in EBC pH and lung function, airway oxidative stress remained increased 4 h after the exposure. Clinical trial registration number (EudraCT): 2009-013545-28. Copyright © 2012 Elsevier Ltd. All rights reserved.

  17. Breath acidification in adolescent runners exposed to atmospheric pollution: A prospective, repeated measures observational study

    Directory of Open Access Journals (Sweden)

    Van Sickle David

    2008-03-01

    Full Text Available Abstract Background Vigorous outdoors exercise during an episode of air pollution might cause airway inflammation. The purpose of this study was to examine the effects of vigorous outdoor exercise during peak smog season on breath pH, a biomarker of airway inflammation, in adolescent athletes. Methods We measured breath pH both pre- and post-exercise on ten days during peak smog season in 16 high school athletes engaged in daily long-distance running in a downwind suburb of Atlanta. The association of post-exercise breath pH with ambient ozone and particulate matter concentrations was tested with linear regression. Results We collected 144 pre-exercise and 146 post-exercise breath samples from 16 runners (mean age 14.9 years, 56% male. Median pre-exercise breath pH was 7.58 (interquartile range: 6.90 to 7.86 and did not change significantly after exercise. We observed no significant association between ambient ozone or particulate matter and post-exercise breath pH. However both pre- and post-exercise breath pH were strikingly low in these athletes when compared to a control sample of 14 relatively sedentary healthy adults and to published values of breath pH in healthy subjects. Conclusion Although we did not observe an acute effect of air pollution exposure during exercise on breath pH, breath pH was surprisingly low in this sample of otherwise healthy long-distance runners. We speculate that repetitive vigorous exercise may induce airway acidification.

  18. Importance of Functional Airway Surgery in Orthognathic Surgery Performed Patients

    Directory of Open Access Journals (Sweden)

    Erkan Yüce

    2017-06-01

    Full Text Available Le Fort I osteotomy is usually combined with mandibular ramus procedures (sagittal split in order to correct dentofacial deformities that cause malocclusion. Patients who have dentofacial anomalies involving the maxilla carry a higher risk of difficulty in breathing due to septal deviation and inferior turbinate hypertrophy. If these conditions are ignored preoperatively, severe airway problems may come up after orthognathic surgery. A detailed examination regarding nasal airway should be conducted in such patients, and they should be informed about their condition which may require an additional intervention during or after their main surgery.

  19. Airway management in neuroanesthesiology.

    Science.gov (United States)

    Aziz, Michael

    2012-06-01

    Airway management for neuroanesthesiology brings together some key principles that are shared throughout neuroanesthesiology. This article appropriately targets the cervical spine with associated injury and the challenges surrounding airway management. The primary focus of this article is on the unique airway management obstacles encountered with cervical spine injury or cervical spine surgery, and unique considerations regarding functional neurosurgery are addressed. Furthermore, topics related to difficult airway management for those with rheumatoid arthritis or pituitary surgery are reviewed. Copyright © 2012 Elsevier Inc. All rights reserved.

  20. Randomized crossover comparison of the laryngeal mask airway classic with i-gel laryngeal mask airway in the management of difficult airway in post burn neck contracture patients

    Directory of Open Access Journals (Sweden)

    Jeevan Singh

    2012-01-01

    Full Text Available Purpose: The objective of the study was to compare the performance of i-gel supraglottic airway with cLMA in difficult airway management in post burn neck contracture patients and assess the feasibility of i-gel use for emergency airway management in difficult airway situation with reduced neck movement and limited mouth opening. Methods: Prospective, crossover, randomized controlled trial was performed amongst forty eight post burn neck contracture patients with limited mouth opening and neck movement. i-gel and cLMA were placed in random order in each patient. Primary outcome was overall success rate. Other measurements were time to successful ventilation, airway leak pressure, fiberoptic glottic view, visualization of square wave pattern. Results: Success rate for the i-gel was 91.7% versus 79.2% for the cLMA. i-gel required shorter insertion time (19.3 seconds vs. 23.5 seconds, P=0.000. Airway leak pressure difference was statistically significant (i-gel 21.2 cm H20; cLMA 16.9 cm H 2 0; P=0.00. Fiberoptic view through the i-gel showed there were less epiglottic downfolding and better fiberoptic view of the glottis than cLMA. Overall agreement in insertion outcome for i-gel was 22/24 (91.7% successes and 2/24(8.3% failure and for cLMA, 19/24 (79.16% successes and 5/24 (16.7% failure in the first attempt. Conclusion: The i-gel is cheap, effective airway device which is easier to insert and has better clinical performance in the difficult airway management of the airway in the post burn contracture of the neck. Our study shows that i-gel is feasible for emergency airway management in difficult airway situation with reduced neck movement and limited mouth opening in post burn neck.

  1. Breath biomarkers in toxicology.

    Science.gov (United States)

    Pleil, Joachim D

    2016-11-01

    Exhaled breath has joined blood and urine as a valuable resource for sampling and analyzing biomarkers in human media for assessing exposure, uptake metabolism, and elimination of toxic chemicals. This article focuses current use of exhaled gas, aerosols, and vapor in human breath, the methods for collection, and ultimately the use of the resulting data. Some advantages of breath are the noninvasive and self-administered nature of collection, the essentially inexhaustible supply, and that breath sampling does not produce potentially infectious waste such as needles, wipes, bandages, and glassware. In contrast to blood and urine, breath samples can be collected on demand in rapid succession and so allow toxicokinetic observations of uptake and elimination in any time frame. Furthermore, new technologies now allow capturing condensed breath vapor directly, or just the aerosol fraction alone, to gain access to inorganic species, lung pH, proteins and protein fragments, cellular DNA, and whole microorganisms from the pulmonary microbiome. Future applications are discussed, especially the use of isotopically labeled probes, non-targeted (discovery) analysis, cellular level toxicity testing, and ultimately assessing "crowd breath" of groups of people and the relation to dose of airborne and other environmental chemicals at the population level.

  2. The Tulip GT® airway versus the facemask and Guedel airway: a randomised, controlled, cross-over study by Basic Life Support-trained airway providers in anaesthetised patients.

    Science.gov (United States)

    Shaikh, A; Robinson, P N; Hasan, M

    2016-03-01

    We performed a randomised, controlled, cross-over study of lung ventilation by Basic Life Support-trained providers using either the Tulip GT® airway or a facemask with a Guedel airway in 60 anaesthetised patients. Successful ventilation was achieved if the provider produced an end-tidal CO2 > 3.5 kPa and a tidal volume > 250 ml in two of the first three breaths, within 60 sec and within two attempts. Fifty-seven (95%) providers achieved successful ventilation using the Tulip GT compared with 35 (58%) using the facemask (p Basic Life Support-trained airway providers. © 2015 The Association of Anaesthetists of Great Britain and Ireland.

  3. Obstetric airway management

    African Journals Online (AJOL)

    of stomach contents into the lungs during obstetric anesthesia.8 ... Both of the mortalities occurred secondary to solid ... The large number of deaths ... subcategories of patients as a first-line airway device, and are increasingly being ... outline the problems with obstetric airway management, and then focus on a few of the ...

  4. Breathing and Relaxation

    Science.gov (United States)

    ... Find a Doctor Relaxation is the absence of tension in muscle groups and a minimum or absence ... Drill Meditation Progressive Muscle Relaxation Minimizing Shortness of Breath Visualization This information has been approved by Shelby ...

  5. Learn More Breathe Better

    Centers for Disease Control (CDC) Podcasts

    Chronic obstructive pulmonary disease (COPD) is a serious lung disease that makes breathing very difficult and can affect your quality of life. Learn the causes of COPD and what you can do to prevent it.

  6. Shortness of Breath

    Science.gov (United States)

    ... filled with air (called pneumotho- rax), it will hinder expansion of the lung, resulting in shortness of ... of Chest Physi- cians. Shortness of Breath: Patient Education. http: / / www. onebreath. org/ document. doc? id= 113. ...

  7. Breath-Holding Spells

    Science.gov (United States)

    ... reviewed: October 2016 More on this topic for: Parents Is It Normal for Children to Hold Their Breath? Taming Tempers Disciplining Your Child Disciplining Your Toddler Temper Tantrums Separation Anxiety View more About Us Contact Us Partners ...

  8. Airway smooth muscle cells : regulators of airway inflammation

    NARCIS (Netherlands)

    Zuyderduyn, Suzanne

    2007-01-01

    Airways from asthmatic subjects are more responsive to bronchoconstrictive stimuli than airways from healthy subjects. Airway smooth muscle (ASM) cells mediate contraction of the airways by responding to the bronchoconstrictive stimuli, which was thought to be the primary role of ASM cells. In this

  9. Ultrafast CT in the diagnosis of sleep apnea during awake tidal breathing

    International Nuclear Information System (INIS)

    Galvin, J.R.; Rooholamini, S.A.; Stanford, W.

    1988-01-01

    With sleep there is normally a decrease in neural output to upper airway muscles. If this decrease is superimposed on a structurally abnormal airway, then sleep apnea may result. Ultrafast CT axially images the upper airway in near real time. The authors compared 11 awake patients with sleep apnea with 24 healthy volunteers during quiet tidal breathing. They found that apneic patients have a small oropharyngeal airway (31.3 mm 2 +- 30.2 vs 134.2 mm 2 +- 46.6[P=<.0001]). Apneic patients also have significant collapsibility of the nasopharynx (75% +- 18% vs 27% +- 14% [P=<.0001]). Ultrafast CT gives dynamic anatomic definition of the upper airway and provides a means to eulcidate further the pathogenesis of sleep apnea

  10. Rule-based detection of intrathoracic airway trees

    International Nuclear Information System (INIS)

    Sonka, M.; Park, W.; Hoffman, E.A.

    1996-01-01

    New sensitive and reliable methods for assessing alterations in regional lung structure and function are critically important for the investigation and treatment of pulmonary diseases. Accurate identification of the airway tree will provide an assessment of airway structure and will provide a means by which multiple volumetric images of the lung at the same lung volume over time can be used to assess regional parenchymal changes. The authors describe a novel rule-based method for the segmentation of airway trees from three-dimensional (3-D) sets of computed tomography (CT) images, and its validation. The presented method takes advantage of a priori anatomical knowledge about pulmonary airway and vascular trees and their interrelationships. The method is based on a combination of 3-D seeded region growing that is used to identify large airways, rule-based two-dimensional (2-D) segmentation of individual CT slices to identify probable locations of smaller diameter airways, and merging of airway regions across the 3-D set of slices resulting in a tree-like airway structure. The method was validated in 40 3-mm-thick CT sections from five data sets of canine lungs scanned via electron beam CT in vivo with lung volume held at a constant pressure. The method's performance was compared with that of the conventional 3-D region growing method. The method substantially outperformed an existing conventional approach to airway tree detection

  11. Chronic adaptations of lung function in breath-hold diving fishermen

    Directory of Open Access Journals (Sweden)

    Cristiane Diniz

    2014-04-01

    Full Text Available Objectives: The aim of this study was to verify and analyze the existence of chronic adaptations of lung function in freediving fishermen whose occupation is artisanal fishing. Material and Methods: This was a cross-sectional study involving 11 breath-hold diving fishermen and 10 non-breath-hold diving fishermen (control from the village of Bitupitá in the municipality of Barroquinha (Ceará - Brazil. Anthropometric measurements, chest and abdominal circumferences as well as spirometric and respiratory muscle strength tests were conducted according to the specifications of the American Thoracic Society/European Respiratory Society (ATS/ERS. In order to compare the measured values versus the predicted values, Student t test was used in the case of parametric test and Wilcoxon test in the case of nonparametric test. To compare the inter-group means Student t test was used for parametric test and Mann-Whitney test for the nonparametric one. The level of significance was set at α = 5%. Results: The forced vital capacity (FVC (4.9±0.6 l vs. 4.3±0.4 l and forced expiratory volume in 1 s (FEV1 (4.0±0.5 l vs. 3.6±0.3 l were, respectively, higher in the group of divers compared to the control group (p ≤ 0.05. Furthermore, in the group of free divers, the measured FVC, FEV1 and FEV1/FVC ratios were significantly greater than the predicted ones. No differences were found between the measured respiratory pressures. Conclusions: These results indicate that breath-hold diving seems to produce chronic adaptations of the respiratory system, resulting in elevated lung volumes with no airway obstruction.

  12. Breath in the technoscientific imaginary

    OpenAIRE

    Rose, Arthur

    2016-01-01

    Breath has a realist function in most artistic media. It serves to remind the reader, the viewer or the spectator of the exigencies of the body. In science fiction (SF) literature and films, breath is often a plot device for human encounters with otherness, either with alien peoples, who may not breathe oxygen, or environments, where there may not be oxygen to breathe. But while there is a technoscientific quality to breath in SF, especially in its attention to physiological systems, concentr...

  13. THE INFLUENCE OF BIOFEEDBACK SESSIONS IN CLOSED LOOP OF HEART RATE VARIABILITY AND PACED BREATHING ON SYSTOLIC BLOOD PRESSURE CONTROL DURING STANDARD DRUG THERAPY IN PATIENTS WITH ARTERIAL HYPERTENSION

    Directory of Open Access Journals (Sweden)

    S. A. S. Belal

    2015-06-01

    Full Text Available Changes of systolic blood pressure (SBP in biofeedback (BFB sessions with closed loop of paced breathing (PB and heart rate variability (HRV during standard drug therapy of arterial hypertension (AH was studied. 275 patients with 1-3 degree of AH (143 men and 132 women, mean age 58,55 ± 7,99 years was divided into two comparable groups: 1 - BFB (139 patients in investigated PB loop, 2 - control group (136 patients with BFB without PB. In both groups was performed 10 sessions of BFB. Changes of SBP depending on the stage and degree of AH, gender and age was assessed. BP was measured by the method of Korotkov’s with monometer Microlife BP AG1-20 in same conditions. Data were processed by parametric and nonparametric statistics. It is proved that the use of biofeedback in the loop of PB and HRV significantly (p < 0.01 exceeds in efficiency an isolated drug therapy in control of SBP at any stage and degree of AH in patients of both sexes in all age groups. Extent of the effect increases with the stage and degree of the disease and not related to the sex and age of the patient. Findings allow to recommend this technique in clinical practice.

  14. Use of extraglottic airways in patients undergoing ambulatory laparoscopic surgery without the need for tracheal intubation

    Directory of Open Access Journals (Sweden)

    T Suhitharan

    2013-01-01

    Full Text Available Background: Second generation extraglottic airway devices with gastric access and separate breathing channels have ushered in a new era where their use is increasingly prevalent in surgical patients who would have been traditionally intubated for general anesthesia. New innovations like the i-gel, which is constructed of a thermoplastic elastomer, provide an airtight seal around patient′s perilaryngeal anatomy without the inflatable cuff mechanism found in the laryngeal mask airway supreme (LMAS. Methods: We conducted a randomized controlled trial comparing the LMAS with the i-gel in 70 anesthetized paralyzed patients undergoing laparoscopic female sterilization. Our primary outcome measure was the oropharyngeal leak pressure (OLP. We studied secondary outcomes of successful first attempt insertion rates, time and ease of the airway and gastric tube insertion, leak fractions and pharyngeal morbidity. Results: We found no difference in the OLP between LMAS and i-gel, 25.9 (4.2 versus 24.4 (4.3 s, P=0.153. Both devices had similar first attempt insertion rates (LMAS 94% vs. i-gel 91% with similar ease and comparable times to achieve an effective airway, LMAS 14.7 (2.7 versus i-gel 16.5 (9.6 s, P=0.306, although gastric tube insertion was easier and faster for the LMAS, 7.9 (1.9 versus i-gel 14.8 (7.7 s, P<0.005. Intraoperatively, there was a significantly greater leak fraction with the i-gel of 0.06 (0.03 versus 0.04 (0.02 with the LMAS, P=0.013. Three patients (8.6% with LMAS had mild sore throat; one patient (2.9% had mucosal injury. No complications were documented in the i-gel group. Conclusions: Both these extraglottic airway devices offer similar OLPs, high insertion success rates at the first attempt with similar ease and insertion times (albeit longer gastric tube insertion with i-gel. Both provided effective ventilation despite a higher leak fraction with i-gel that was clinically inconsequential.

  15. Imposed Work of Breathing and Breathing Comfort of Nonintubated Volunteers Breathing with Three Portable Ventilators and a Critical Care Ventilator

    National Research Council Canada - National Science Library

    Austin, Paul

    2001-01-01

    .... The purpose of this study was to assess the imposed inspiratory work of breathing and breathing comfort of nonintubated healthy volunteers breathing spontaneously through three portable ventilators...

  16. Liquid breathing - Prevention of pulmonary arterial-venous shunting during acceleration.

    Science.gov (United States)

    Sass, D. J.; Ritman, E. L.; Caskey, P. E.; Banchero, N.; Wood, E. H.

    1972-01-01

    Dependent pulmonary atelectasis, arterial-venous shunting, and downward displacement of the heart caused by the gravitational-inertial force environment were prevented in dogs breathing oxygenated liquid fluorocarbon in a whole-body water-immersion respirator. Partial closure of the major airways during part of the expiratory phase of liquid respiration was a significant problem initially but was minimized in subsequent studies.

  17. Role of Aquaporin Water Channels in Airway Fluid Transport, Humidification, and Surface Liquid Hydration

    Science.gov (United States)

    Song, Yuanlin; Jayaraman, Sujatha; Yang, Baoxue; Matthay, Michael A.; Verkman, A.S.

    2001-01-01

    Several aquaporin-type water channels are expressed in mammalian airways and lung: AQP1 in microvascular endothelia, AQP3 in upper airway epithelia, AQP4 in upper and lower airway epithelia, and AQP5 in alveolar epithelia. Novel quantitative methods were developed to compare airway fluid transport–related functions in wild-type mice and knockout mice deficient in these aquaporins. Lower airway humidification, measured from the moisture content of expired air during mechanical ventilation with dry air through a tracheotomy, was 54–56% efficient in wild-type mice, and reduced by only 3–4% in AQP1/AQP5 or AQP3/AQP4 double knockout mice. Upper airway humidification, measured from the moisture gained by dry air passed through the upper airways in mice breathing through a tracheotomy, decreased from 91 to 50% with increasing ventilation from 20 to 220 ml/min, and reduced by 3–5% in AQP3/AQP4 knockout mice. The depth and salt concentration of the airway surface liquid in trachea was measured in vivo using fluorescent probes and confocal and ratio imaging microscopy. Airway surface liquid depth was 45 ± 5 μm and [Na+] was 115 ± 4 mM in wild-type mice, and not significantly different in AQP3/AQP4 knockout mice. Osmotic water permeability in upper airways, measured by an in vivo instillation/sample method, was reduced by ∼40% by AQP3/AQP4 deletion. In doing these measurements, we discovered a novel amiloride-sensitive isosmolar fluid absorption process in upper airways (13% in 5 min) that was not affected by aquaporin deletion. These results establish the fluid transporting properties of mouse airways, and indicate that aquaporins play at most a minor role in airway humidification, ASL hydration, and isosmolar fluid absorption. PMID:11382807

  18. The effect of CO2 on ventilation and breath-holding during exercise and while breathing through an added resistance.

    Science.gov (United States)

    Clark, T J; Godfrey, S

    1969-05-01

    1. Ventilation was measured while subjects were made to rebreathe from a bag containing CO(2) and O(2) in order to expose them to a steadily rising CO(2) tension (P(CO2)). The object of the experiments was to determine the effect of a variety of stimuli upon the increase in ventilation and fall in breath-holding time which occurs in response to the rising P(CO2).2. Steady-state exercise at 200 kg.m/min resulted in a small fall in the slope of the ventilation-CO(2) response curve (S(V)) and a small, though not statistically significant, fall in the P(CO2) at which ventilation would be zero by extrapolation (B(V)). There was a marked fall in the slope of the breath-holding-CO(2) response curve (S(BH)) and an increase in the P(CO2) at which breath-holding time became zero by extrapolation (B(BH)).3. These results have been interpreted with the aid of a model of the control of breath-holding and it is suggested that there is no change in CO(2) sensitivity on exercise, either during rebreathing or breath-holding.4. An increase in the resistance to breathing caused a marked reduction in S(V) and B(V), but no change in the breath-holding-CO(2) response curve. These findings suggest that the flattening of the ventilation-CO(2) response curve is mechanical in origin and acute airway obstruction produces no change in CO(2) sensitivity.5. On the basis of these results, we suggest that more information about CO(2) sensitivity can be obtained by a combination of ventilation and breath-holding-CO(2) response curves.

  19. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... There are different ways to clear your airways. Most are easy to do. Infants and toddlers will ... best ACT is the one that you are most likely to perform as part of your daily ...

  20. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... about the needs of people with cystic fibrosis so that they make smart decisions about CF-related ... then move the mucus out of the airways so it can be coughed out. These medications can ...

  1. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... in CF Clinical Care Guidelines Cystic Fibrosis-Related Diabetes Clinical Care Guidelines Liver Disease Clinical Care Guidelines Respiratory Care Guidelines CF Airway Clearance Therapies Clinical Care Guidelines Chronic Medications to Maintain Lung ...

  2. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Community in Health Care Reform Milestones in Health Care Reform How Tax Reform Could Impact People With CF The ... Home Life With CF Treatments and Therapies Airway Clearance ...

  3. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Clinical Care Guidelines Liver Disease Clinical Care Guidelines Respiratory Care Guidelines CF Airway Clearance Therapies Clinical Care ... attack bacteria. Choose What's Best for You Your respiratory therapist or another member of your CF care ...

  4. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... toddlers will need help from a parent or caregiver. Older kids and adults can choose ACTs that ... into the smaller airways to attack bacteria. Choose What's Best for You Your respiratory therapist or another ...

  5. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... that help thin and move the mucus, and antibiotics. Bronchodilators should be inhaled before you start ACTs. This medication helps to widen your airways (bronchi) by relaxing the ...

  6. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... people with cystic fibrosis so that they make smart decisions about CF-related research, treatment, and access ... Facebook Twitter YouTube Instagram Email DONATE Breadcrumb Navigation Home Life With CF Treatments and Therapies Airway Clearance ...

  7. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... in part to specialized CF care and a range of treatment options. Airway Clearance Active Cycle of ... a cure for CF and supports a broad range of research initiatives to tackle the disease from ...

  8. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... huffing . Many of them use percussion (clapping) or vibration to loosen mucus from airway walls. See how ... What is CF? About Cystic Fibrosis CF Genetics Diagnosis Testing for CF Life With CF Caring for ...

  9. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... CFTR Modulator Therapies Mucus Thinners Nebulizer Care at Home Vascular Access Devices PICCs and Ports Partnerships for ... Facebook Twitter YouTube Instagram Email DONATE Breadcrumb Navigation Home Life With CF Treatments and Therapies Airway Clearance ...

  10. Fisioterapia respiratória associada à pressão positiva nas vias aéreas na evolução pós-operatória da cirurgia bariátrica Respiratory physiotherapy associated with airway positive pressure in the postoperative bariatric surgery evolution

    Directory of Open Access Journals (Sweden)

    Fabiana Sobral Peixoto-Souza

    2012-09-01

    Full Text Available Analisar volume corrente (VC, volume minuto (VM e frequência respiratória (FR de obesas mórbidas no pós-operatório de cirurgia bariátrica (CB, após a fisioterapia respiratória convencional (FRC associada ou não à pressão positiva contínua nas vias aéreas (CPAP no pré-operatório. Foram estudadas 36 mulheres, com idade de 40,1±8,41 anos, que seriam submetidas à CB por laparotomia e que realizaram FRC (exercícios respiratórios diafragmáticos, de inspirações profundas, fracionadas e associados a movimentos de membros superiores, 1 série de 10 repetições de cada exercício por 30 dias antes da cirurgia. Após internação, 18 delas foram submetidas a 20 minutos de CPAP, 1 hora antes da indução anestésica e compuseram o grupo FRC+CPAP. As outras 18 não receberam o CPAP e compuseram o grupo FRC. Foram avaliados VM, VC e FR por meio do ventilômetro, no momento da internação e 24 horas após a realização da cirurgia. Constatou-se que as medidas de VC, VM e FR não apresentaram significância estatística quando comparados os resultados do pré e pós-operatório em ambos os grupos, bem como quando comparados os dois grupos entre si tanto no pré como no pós-operatório. Os resultados sugerem que a tanto a aplicação da FRC como a aplicação da FRC+CPAP no período pré-operatório contribui para a manutenção das variáveis respiratórias no pós-operatório. A aplicação do CPAP antes da indução anestésica não promoveu benefícios adicionais no pós-operatório de CB no que se refere aos volumes pulmonares.To assess the tidal volume (VT, minute volume (MV and respiratory rate (RR of morbidly obese women in postoperative bariatric surgery (BS, after the conventional respiratory physiotherapy (CRP with or without preoperatively continuous positive airway pressure (CPAP. Thirty-six women, aged 40.1±8.41 years, that would be submitted to BS by laparotomy were studied. All of them underwent preoperative outpatient

  11. Imposed Work of Breathing for Flow Meters with In-Line versus Flow-Through Technique during Simulated Neonatal Breathing.

    Directory of Open Access Journals (Sweden)

    Snorri Donaldsson

    Full Text Available The ability to determine airflow during nasal CPAP (NCPAP treatment without adding dead space or resistance would be useful when investigating the physiologic effects of different NCPAP systems on breathing. The aim of this study was to investigate the effect on pressure stability of different flow measuring devices at the in-line and flow-through position, using simulated neonatal breathing.Six different flow measure devices were evaluated by recording pressure changes and imposed work of breathing for breaths with 16 and 32 ml tidal volumes. The tests were performed initially with the devices in an in line position and with 5 and 10 L/min using flow through technique, without CPAP. The flow meters were then subsequently tested with an Infant Flow CPAP system at 3, 5 and 8 cm H2O pressure using flow through technique. The quality of the recorded signals was compared graphically.The resistance of the measuring devices generated pressure swings and imposed work of breathing. With bias flow, the resistance also generated CPAP pressure. Three of the devices had low resistance and generated no changes in pressure stability or CPAP pressure. The two devices intended for neonatal use had the highest measured resistance.The importance of pressure stability and increased work of breathing during non-invasive respiratory support are insufficiently studied. Clinical trials using flow-through technique have not focused on pressure stability. Our results indicate that a flow-through technique might be a way forward in obtaining a sufficiently high signal quality without the added effects of rebreathing and increased work of breathing. The results should stimulate further research and the development of equipment for dynamic flow measurements in neonates.

  12. Imposed Work of Breathing for Flow Meters with In-Line versus Flow-Through Technique during Simulated Neonatal