WorldWideScience

Sample records for aircraft multispectral scanner

  1. Inland wetland change detection using aircraft MSS [multispectral scanner] data

    International Nuclear Information System (INIS)

    Jensen, J.R.; Ramsey, E.W.; Mackey, H.E. Jr.; Sharitz, R.R.; Christensen, E.J.

    1986-01-01

    Nontidal wetlands in a portion of the Savannah River swamp forest affected by reactor cooling water discharges were mapped using March 31, 1981 and April 29, 1985 high-resolution aircraft multispectral scanner (MSS) data. Due to the inherent distortion in the aircraft MSS data and the complex spectral characteristics of the wetland vegetation, it was necessary to implement multiple techniques in the registration and classification of the MSS imagery of the Pen Branch Delta on each date. In particular, it was necessary to use a piecewise-linear registration process over relatively small regions to perform image-to-image registration. When performing unsupervised classification, an iterative ''cluster busting'' technique was used, which simplified the cluster labeling process. These procedures allowed important wetland vegetation categories to be identified on each date. The multiple-date classification maps were then evaluated using a post-classification comparison technique yielding change classes that were of value in determining the extent of inland wetland change in this region

  2. Quantitative analysis of aircraft multispectral-scanner data and mapping of water-quality parameters in the James River in Virginia

    Science.gov (United States)

    Johnson, R. W.; Bahn, G. S.

    1977-01-01

    Statistical analysis techniques were applied to develop quantitative relationships between in situ river measurements and the remotely sensed data that were obtained over the James River in Virginia on 28 May 1974. The remotely sensed data were collected with a multispectral scanner and with photographs taken from an aircraft platform. Concentration differences among water quality parameters such as suspended sediment, chlorophyll a, and nutrients indicated significant spectral variations. Calibrated equations from the multiple regression analysis were used to develop maps that indicated the quantitative distributions of water quality parameters and the dispersion characteristics of a pollutant plume entering the turbid river system. Results from further analyses that use only three preselected multispectral scanner bands of data indicated that regression coefficients and standard errors of estimate were not appreciably degraded compared with results from the 10-band analysis.

  3. Demonstration of wetland vegetation mapping in Florida from computer-processed satellite and aircraft multispectral scanner data

    Science.gov (United States)

    Butera, M. K.

    1979-01-01

    The success of remotely mapping wetland vegetation of the southwestern coast of Florida is examined. A computerized technique to process aircraft and LANDSAT multispectral scanner data into vegetation classification maps was used. The cost effectiveness of this mapping technique was evaluated in terms of user requirements, accuracy, and cost. Results indicate that mangrove communities are classified most cost effectively by the LANDSAT technique, with an accuracy of approximately 87 percent and with a cost of approximately 3 cent per hectare compared to $46.50 per hectare for conventional ground survey methods.

  4. A Cost Effective Multi-Spectral Scanner for Natural Gas Detection

    Energy Technology Data Exchange (ETDEWEB)

    Yudaya Sivathanu; Jongmook Lim; Vinoo Narayanan; Seonghyeon Park

    2005-12-07

    The objective of this project is to design, fabricate and demonstrate a cost effective, multi-spectral scanner for natural gas leak detection in transmission and distribution pipelines. During the first year of the project, a laboratory version of the multi-spectral scanner was designed, fabricated, and tested at EnUrga Inc. The multi-spectral scanner was also evaluated using a blind Department of Energy study at the Rocky Mountain Oilfield Testing Center. The performance of the scanner was inconsistent during the blind study. However, most of the leaks were outside the view of the multi-spectral scanner that was developed during the first year of the project. Therefore, a definite evaluation of the capability of the scanner was not obtained. Despite the results, sufficient number of plumes was detected fully confirming the feasibility of the multi-spectral scanner. During the second year, the optical design of the scanner was changed to improve the sensitivity of the system. Laboratory tests show that the system can reliably detect small leaks (20 SCFH) at 30 to 50 feet. A prototype scanner was built and evaluated during the second year of the project. Only laboratory evaluations were completed during the second year. The laboratory evaluations show the feasibility of using the scanner to determine natural gas pipeline leaks. Further field evaluations and optimization of the scanner are required before commercialization of the scanner can be initiated.

  5. Landsat 1-5 Multispectral Scanner V1

    Data.gov (United States)

    National Aeronautics and Space Administration — Abstract: The Landsat Multispectral Scanner (MSS) was a sensor onboard Landsats 1 through 5 and acquired images of the Earth nearly continuously from July 1972 to...

  6. A multispectral scanner survey of the Idaho National Engineering Laboratory and the Hanford Reservation

    International Nuclear Information System (INIS)

    Brewster, S.B. Jr.; Howard, M.E.; Shines, J.E.

    1994-09-01

    An airborne multispectral scanner survey of selected sites on the Idaho National Engineering Laboratory and the Hanford Reservation was performed in mid-November 1993. Aerial multispectral scanner and photography data were acquired coincidentally with the Big O experiment at both locations. To illustrate two potential applications, the multispectral scanner data were digitally enhanced to facilitate the detection of soil disturbance and evidence of surface water transport. The main conclusion of this study was that multispectral data acquired under these conditions can be useful for soil disturbance detection. The imagery did not prove as useful, however, for direct indications of surface water transport. It was possible to infer some water transport patterns from dry water beds, but only if surface indications were present

  7. A multispectral scanner survey of the Rocky Flats Environmental Technology Site and surrounding area, Golden, Colorado

    International Nuclear Information System (INIS)

    Brewster, S.B. Jr.; Brickey, D.W.; Ross, S.L.; Shines, J.E.

    1997-04-01

    Aerial multispectral scanner imagery was collected of the Rocky Flats Environmental Technology Site in Golden, Colorado, on June 3, 5, 6, and 7, 1994, using a Daedalus AADS1268 multispectral scanner and coincident aerial color and color infrared photography. Flight altitudes were 4,500 feet (1372 meters) above ground level to match prior 1989 survey data; 2,000 feet (609 meters) above ground level for sitewide vegetation mapping; and 1,000 feet (304 meters) above ground level for selected areas of special interest. A multispectral survey was initiated to improve the existing vegetation classification map, to identify seeps and springs, and to generate ARC/INFO Geographic Information System compatible coverages of the vegetation and wetlands for the entire site including the buffer zone. The multispectral scanner imagery and coincident aerial photography were analyzed for the detection, identification, and mapping of vegetation and wetlands. The multispectral scanner data were processed digitally while the color and color infrared photography were manually photo-interpreted to define vegetation and wetlands. Several standard image enhancement techniques were applied to the multispectral scanner data to assist image interpretation. A seep enhancement was applied and a color composite consisting of multispectral scanner channels 11, 7, and 5 (thermal infrared, mid-infrared, and red bands, respectively) proved most useful for detecting seeps, seep zones, and springs. The predawn thermal infrared data were also useful in identifying and locating seeps. The remote sensing data, mapped wetlands, and ancillary Geographic Information System compatible data sets were spatially analyzed for seeps

  8. Multi-spectral optical scanners for commercial earth observation missions

    Science.gov (United States)

    Schröter, Karin; Engel, Wolfgang; Berndt, Klaus

    2017-11-01

    In recent years, a number of commercial Earth observation missions have been initiated with the aim to gather data in the visible and near-infrared wavelength range. Some of these missions aim at medium resolution (5 to 10 m) multi-spectral imaging with the special background of daily revisiting. Typical applications aim at monitoring of farming area for growth control and harvest prediction, irrigation control, or disaster monitoring such as hail damage in farming, or flood survey. In order to arrive at profitable business plans for such missions, it is mandatory to establish the space segment, i.e. the spacecraft with their opto -electronic payloads, at minimum cost while guaranteeing maximum reliability for mission success. As multiple spacecraft are required for daily revisiting, the solutions are typically based on micro-satellites. This paper presents designs for multi-spectral opto-electric scanners for this type of missions. These designs are drive n by minimum mass and power budgets of microsatellites, and the need for minimum cost. As a consequence, it is mandatory to arrive at thermally robust, compact telescope designs. The paper gives a comparison between refractive, catadioptric, and TMA optics. For mirror designs, aluminium and Zerodur mirror technologies are briefly discussed. State-of-the art focal plane designs are presented. The paper also addresses the choice of detector technologies such as CCDs and CMOS Active Pixel Sensors. The electronics of the multi-spectral scanners represent the main design driver regarding power consumption, reliability, and (most often) cost. It can be subdivided into the detector drive electronics, analog and digital data processing chains, the data mass memory unit, formatting and down - linking units, payload control electronics, and local power supply. The paper gives overviews and trade-offs between data compression strategies and electronics solutions, mass memory unit designs, and data formatting approaches

  9. A demonstration of wetland vegetation mapping in Florida from computer-processed satellite and aircraft multispectral scanner data

    Science.gov (United States)

    Butera, M. K. (Principal Investigator)

    1978-01-01

    The author has identified the following significant results. Major vegetative classes identified by the remote sensing technique were cypress swamp, pine, wetland grasses, salt grass, mixed mangrove, black mangrove, Brazilian pepper. Australian pine and melaleuca were not satisfactorily classified from LANDSAT. Aircraft scanners provided better resolution resulting in a classification of finer surface detail. An edge effect, created by the integration of diverse spectral responses within boundary elements of digital data, affected the wetlands classification. Accuracy classification for aircraft was 68% and for LANDSAT was 74%.

  10. Multispectral data compression through transform coding and block quantization

    Science.gov (United States)

    Ready, P. J.; Wintz, P. A.

    1972-01-01

    Transform coding and block quantization techniques are applied to multispectral aircraft scanner data, and digitized satellite imagery. The multispectral source is defined and an appropriate mathematical model proposed. The Karhunen-Loeve, Fourier, and Hadamard encoders are considered and are compared to the rate distortion function for the equivalent Gaussian source and to the performance of the single sample PCM encoder.

  11. A multispectral scanner survey of the Tonopah Test Range, Nevada. Date of survey: August 1993

    International Nuclear Information System (INIS)

    Brewster, S.B. Jr.; Howard, M.E.; Shines, J.E.

    1994-08-01

    The Multispectral Remote Sensing Department of the Remote Sensing Laboratory conducted an airborne multispectral scanner survey of a portion of the Tonopah Test Range, Nevada. The survey was conducted on August 21 and 22, 1993, using a Daedalus AADS1268 scanner and coincident aerial color photography. Flight altitudes were 5,000 feet (1,524 meters) above ground level for systematic coverage and 1,000 feet (304 meters) for selected areas of special interest. The multispectral scanner survey was initiated as part of an interim and limited investigation conducted to gather preliminary information regarding historical hazardous material release sites which could have environmental impacts. The overall investigation also includes an inventory of environmental restoration sites, a ground-based geophysical survey, and an aerial radiological survey. The multispectral scanner imagery and coincident aerial photography were analyzed for the detection, identification, and mapping of man-made soil disturbances. Several standard image enhancement techniques were applied to the data to assist image interpretation. A geologic ratio enhancement and a color composite consisting of AADS1268 channels 10, 7, and 9 (mid-infrared, red, and near-infrared spectral bands) proved most useful for detecting soil disturbances. A total of 358 disturbance sites were identified on the imagery and mapped using a geographic information system. Of these sites, 326 were located within the Tonopah Test Range while the remaining sites were present on the imagery but outside the site boundary. The mapped site locations are being used to support ongoing field investigations

  12. Multispectral remote sensing of inland wetlands in South Carolina: selecting the appropriate sensor

    International Nuclear Information System (INIS)

    Jensen, J.R.; Hodgson, M.; Christensen, E.J.; Mackey, H.E.; Sharitz, R.R.

    1984-01-01

    This research summarizes the utility of remote sensing for mapping both local (SRP) and regional wetlands including: stream delta areas, using aircraft multispectral scanner (MSS) imagery and large scale aerial photography; the SRP river swamp, using aircraft MSS and LANDSAT thematic mapper imagery; the Savannah River watershed, using LANDSAT MSS Imagery

  13. The role of multispectral scanners as data sources for EPA hydrologic models

    Science.gov (United States)

    Slack, R.; Hill, D.

    1982-01-01

    An estimated cost savings of 30% to 50% was realized from using LANDSAT-derived data as input into a program which simulates hydrologic and water quality processes in natural and man-made water systems. Data from the satellite were used in conjunction with EPA's 11-channel multispectral scanner to obtain maps for characterizing the distribution of turbidity plumes in Flathead Lake and to predict the effect of increasing urbanization in Montana's Flathead River Basin on the lake's trophic state. Multispectral data are also being studied as a possible source of the parameters needed to model the buffering capability of lakes in an effort to evaluate the effect of acid rain in the Adirondacks. Water quality in Lake Champlain, Vermont is being classified using data from the LANDSAT and the EPA MSS. Both contact-sensed and MSS data are being used with multivariate statistical analysis to classify the trophic status of 145 lakes in Illinois and to identify water sampling sites in Appalachicola Bay where contaminants threaten Florida's shellfish.

  14. Assessment of Landsat multispectral scanner spectral indexes for monitoring arid rangeland

    Science.gov (United States)

    Musick, H. B.

    1984-01-01

    Correlations between spectral indices and vegetation parameters in south-central New Mexico were used to determine the utility of Landsat Multispectral Scanner (MSS) spectral indices in arid rangeland monitoring. In addition, spectral index change for 1976-1980 was calculated from retrospective MSS data and compared with qualitative ground truth in order to evaluate vegetation change detection by means of spectral indices. Brightness index change consistently differentiated between cover increase and decrease, but index change appears to have been offset from true cover change; this may at least partly be attributed to the failure of the methods used to standardize MSS scenes for differences in sensor response. Green vegetation indices, by contrast to brightness indices, failed to consistently differentiate between cover increase and decrease.

  15. A multilevel multispectral data set analysis in the visible and infrared wavelength regions. [for land use remote sensing

    Science.gov (United States)

    Biehl, L. L.; Silva, L. F.

    1975-01-01

    Skylab multispectral scanner data, digitized Skylab color infrared (IR) photography, digitized Skylab black and white multiband photography, and Earth Resources Technology Satellite (ERTS) multispectral scanner data collected within a 24-hr time period over an area in south-central Indiana near Bloomington on June 9 and 10, 1973, were compared in a machine-aided land use analysis of the area. The overall classification performance results, obtained with nine land use classes, were 87% correct classification using the 'best' 4 channels of the Skylab multispectral scanner, 80% for the channels on the Skylab multispectral scanner which are spectrally comparable to the ERTS multispectral scanner, 88% for the ERTS multispectral scanner, 83% for the digitized color IR photography, and 76% for the digitized black and white multiband photography. The results indicate that the Skylab multispectral scanner may yield even higher classification accuracies when a noise-filtered multispectral scanner data set becomes available in the near future.

  16. Object-based analysis of multispectral airborne laser scanner data for land cover classification and map updating

    Science.gov (United States)

    Matikainen, Leena; Karila, Kirsi; Hyyppä, Juha; Litkey, Paula; Puttonen, Eetu; Ahokas, Eero

    2017-06-01

    During the last 20 years, airborne laser scanning (ALS), often combined with passive multispectral information from aerial images, has shown its high feasibility for automated mapping processes. The main benefits have been achieved in the mapping of elevated objects such as buildings and trees. Recently, the first multispectral airborne laser scanners have been launched, and active multispectral information is for the first time available for 3D ALS point clouds from a single sensor. This article discusses the potential of this new technology in map updating, especially in automated object-based land cover classification and change detection in a suburban area. For our study, Optech Titan multispectral ALS data over a suburban area in Finland were acquired. Results from an object-based random forests analysis suggest that the multispectral ALS data are very useful for land cover classification, considering both elevated classes and ground-level classes. The overall accuracy of the land cover classification results with six classes was 96% compared with validation points. The classes under study included building, tree, asphalt, gravel, rocky area and low vegetation. Compared to classification of single-channel data, the main improvements were achieved for ground-level classes. According to feature importance analyses, multispectral intensity features based on several channels were more useful than those based on one channel. Automatic change detection for buildings and roads was also demonstrated by utilising the new multispectral ALS data in combination with old map vectors. In change detection of buildings, an old digital surface model (DSM) based on single-channel ALS data was also used. Overall, our analyses suggest that the new data have high potential for further increasing the automation level in mapping. Unlike passive aerial imaging commonly used in mapping, the multispectral ALS technology is independent of external illumination conditions, and there are

  17. Assessment of Pen Branch delta and corridor vegetation changes using multispectral scanner data 1992--1994

    International Nuclear Information System (INIS)

    1996-01-01

    Airborne multispectral scanner data were used to monitor natural succession of wetland vegetation species over a three-year period from 1992 through 1994 for Pen Branch on the Savannah River Site in South Carolina. Image processing techniques were used to identify and measure wetland vegetation communities in the lower portion of the Pen Branch corridor and delta. The study provided a reliable means for monitoring medium- and large-scale changes in a diverse environment. Findings from the study will be used to support decisions regarding remediation efforts following the cessation of cooling water discharge from K reactor at the Department of Energy's Savannah River Site in South Carolina

  18. Conical scan impact study. Volume 2: Small local user data processing facility. [multispectral band scanner design alternatives for earth resources data

    Science.gov (United States)

    Ebert, D. H.; Chase, P. E.; Dye, J.; Fahline, W. C.; Johnson, R. H.

    1973-01-01

    The impact of a conical scan versus a linear scan multispectral scanner (MSS) instrument on a small local-user data processing facility was studied. User data requirements were examined to determine the unique system rquirements for a low cost ground system (LCGS) compatible with the Earth Observatory Satellite (EOS) system. Candidate concepts were defined for the LCGS and preliminary designs were developed for selected concepts. The impact of a conical scan MSS versus a linear scan MSS was evaluated for the selected concepts. It was concluded that there are valid user requirements for the LCGS and, as a result of these requirements, the impact of the conical scanner is minimal, although some new hardware development for the LCGS is necessary to handle conical scan data.

  19. Preliminary analysis of the forest health state based on multispectral images acquired by Unmanned Aerial Vehicle

    Directory of Open Access Journals (Sweden)

    Czapski Paweł

    2015-09-01

    Full Text Available The main purpose of this publication is to present the current progress of the work associated with the use of a lightweight unmanned platforms for various environmental studies. Current development in information technology, electronics and sensors miniaturisation allows mounting multispectral cameras and scanners on unmanned aerial vehicle (UAV that could only be used on board aircraft and satellites. Remote Sensing Division in the Institute of Aviation carries out innovative researches using multisensory platform and lightweight unmanned vehicle to evaluate the health state of forests in Wielkopolska province. In this paper, applicability of multispectral images analysis acquired several times during the growing season from low altitude (up to 800m is presented. We present remote sensing indicators computed by our software and common methods for assessing state of trees health. The correctness of applied methods is verified using analysis of satellite scenes acquired by Landsat 8 OLI instrument (Operational Land Imager.

  20. Restoration of Hyperspectral Push-Broom Scanner Data

    DEFF Research Database (Denmark)

    Larsen, Rasmus; Nielsen, Allan Aasbjerg; Conradsen, Knut

    1997-01-01

    Several effects combine to distort the multispectral data that are obtained from push-broom scanners. We develop an algorithm for restoration of such data, illustrated on images from the ROSIS scanner. In push-broom scanners variation between elements in the detector array results in a strong...... back into the original spectral space results in noise corrected variables. The noise components will now have been removed from the entire original data set by working on a smaller set of noise contaminated transformed variables only. The application of the above techniques results in a dramatic...

  1. An aerial multispectral thermographic survey of the Oak Ridge Reservation for selected areas K-25, X-10, and Y-12, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    Ginsberg, I.W.

    1996-10-01

    During June 5-7, 1996, the Department of Energy's Remote Sensing Laboratory performed day and night multispectral surveys of three areas at the Oak Ridge Reservation: K-25, X-10, and Y-12. Aerial imagery was collected with both a Daedalus DS1268 multispectral scanner and National Aeronautics and Space Administration's Thermal Infrared Multispectral System, which has six bands in the thermal infrared region of the spectrum. Imagery from the Thermal Infrared Multispectral System was processed to yield images of absolute terrain temperature and of the terrain's emissivities in the six spectral bands. The thermal infrared channels of the Daedalus DS1268 were radiometrically calibrated and converted to apparent temperature. A recently developed system for geometrically correcting and geographically registering scanner imagery was used with the Daedalus DS1268 multispectral scanner. The corrected and registered 12-channel imagery was orthorectified using a digital elevation model. 1 ref., 5 figs., 5 tabs

  2. Multispectral Landsat images of Antartica

    Energy Technology Data Exchange (ETDEWEB)

    Lucchitta, B.K.; Bowell, J.A.; Edwards, K.L.; Eliason, E.M.; Fergurson, H.M.

    1988-01-01

    The U.S. Geological Survey has a program to map Antarctica by using colored, digitally enhanced Landsat multispectral scanner images to increase existing map coverage and to improve upon previously published Landsat maps. This report is a compilation of images and image mosaic that covers four complete and two partial 1:250,000-scale quadrangles of the McMurdo Sound region.

  3. Airborne Thermal Infrared Multispectral Scanner (TIMS) images over disseminated gold deposits, Osgood Mountains, Humboldt County, Nevada

    Science.gov (United States)

    Krohn, M. Dennis

    1986-01-01

    The U.S. Geological Survey (USGS) acquired airborne Thermal Infrared Multispectral Scanner (TIMS) images over several disseminated gold deposits in northern Nevada in 1983. The aerial surveys were flown to determine whether TIMS data could depict jasperoids (siliceous replacement bodies) associated with the gold deposits. The TIMS data were collected over the Pinson and Getchell Mines in the Osgood Mountains, the Carlin, Maggie Creek, Bootstrap, and other mines in the Tuscarora Mountains, and the Jerritt Canyon Mine in the Independence Mountains. The TIMS data seem to be a useful supplement to conventional geochemical exploration for disseminated gold deposits in the western United States. Siliceous outcrops are readily separable in the TIMS image from other types of host rocks. Different forms of silicification are not readily separable, yet, due to limitations of spatial resolution and spectral dynamic range. Features associated with the disseminated gold deposits, such as the large intrusive bodies and fault structures, are also resolvable on TIMS data. Inclusion of high-resolution thermal inertia data would be a useful supplement to the TIMS data.

  4. Discrimination techniques employing both reflective and thermal multispectral signals. [for remote sensor technology

    Science.gov (United States)

    Malila, W. A.; Crane, R. B.; Richardson, W.

    1973-01-01

    Recent improvements in remote sensor technology carry implications for data processing. Multispectral line scanners now exist that can collect data simultaneously and in registration in multiple channels at both reflective and thermal (emissive) wavelengths. Progress in dealing with two resultant recognition processing problems is discussed: (1) More channels mean higher processing costs; to combat these costs, a new and faster procedure for selecting subsets of channels has been developed. (2) Differences between thermal and reflective characteristics influence recognition processing; to illustrate the magnitude of these differences, some explanatory calculations are presented. Also introduced, is a different way to process multispectral scanner data, namely, radiation balance mapping and related procedures. Techniques and potentials are discussed and examples presented.

  5. Foreign object detection in multispectral X-ray images of food items using sparse discriminant analysis

    DEFF Research Database (Denmark)

    Einarsson, Gudmundur; Jensen, Janus Nørtoft; Paulsen, Rasmus Reinhold

    2017-01-01

    Non-invasive food inspection and quality assurance are becoming viable techniques in food production due to the introduction of fast and accessible multispectral X-ray scanners. However, the novel devices produce massive amount of data and there is a need for fast and accurate algorithms for proc......Non-invasive food inspection and quality assurance are becoming viable techniques in food production due to the introduction of fast and accessible multispectral X-ray scanners. However, the novel devices produce massive amount of data and there is a need for fast and accurate algorithms...... computational properties, which allows for fast classification of items in new images....

  6. Aircraft scanner data availability via the version 0 Information Management System

    Science.gov (United States)

    Mah, G. R.

    1995-01-01

    As part of the Earth Observing System Data and Information System (EOSDIS) development, NASA and other government agencies have developed an operational prototype of the Information Management System (IMS). The IMS provides access to the data archived at the Distributed Active Archive Centers (DAAC's) that allows users to search through metadata describing the (image) data. Criteria based on sensor name or type, date and time, and geographic location are used to search the archive. Graphical representations of coverage and browse images are available to further refine a user's selection. previously, the EROS Data Center (EDC) DAAC had identified the Advanced SOlid-state Array Spectrometer (ASAS), Airborne Visible and infrared Imaging Spectrometer (AVIRIS), NS-001, and Thermal Infrared Multispectral Scanner (TIMS) as precursor data sets similar to those the DAAC will handle in the Earth Observing System era. Currently, the EDC DAAC staff, in cooperation with NASA, has transcribed TIMS, NS-001, and Thematic Mapper Simulation (TMS) data from Ames Research Center and also TIMS data from Stennis Space Center. During the transcription process, the IMS metadata and browse images were created to populate the inventory at the EDC DAAC. These data sets are now available in the IMS and may be requested from the any of the DAAC's via the IMS.

  7. Ikhana: Unmanned Aircraft System Western States Fire Missions. Monographs in Aerospace History, Number 44

    Science.gov (United States)

    Merlin, Peter W.

    2009-01-01

    In 2006, NASA Dryden Flight Research Center, Edwards, Calif., obtained a civil version of the General Atomics MQ-9 unmanned aircraft system and modified it for research purposes. Proposed missions included support of Earth science research, development of advanced aeronautical technology, and improving the utility of unmanned aerial systems in general. The project team named the aircraft Ikhana a Native American Choctaw word meaning intelligent, conscious, or aware in order to best represent NASA research goals. Building on experience with these and other unmanned aircraft, NASA scientists developed plans to use the Ikhana for a series of missions to map wildfires in the western United States and supply the resulting data to firefighters in near-real time. A team at NASA Ames Research Center, Mountain View, Calif., developed a multispectral scanner that was key to the success of what became known as the Western States Fire Missions. Carried out by team members from NASA, the U.S. Department of Agriculture Forest Service, National Interagency Fire Center, National Oceanic and Atmospheric Administration, Federal Aviation Administration, and General Atomics Aeronautical Systems Inc., these flights represented an historic achievement in the field of unmanned aircraft technology.

  8. An integrated compact airborne multispectral imaging system using embedded computer

    Science.gov (United States)

    Zhang, Yuedong; Wang, Li; Zhang, Xuguo

    2015-08-01

    An integrated compact airborne multispectral imaging system using embedded computer based control system was developed for small aircraft multispectral imaging application. The multispectral imaging system integrates CMOS camera, filter wheel with eight filters, two-axis stabilized platform, miniature POS (position and orientation system) and embedded computer. The embedded computer has excellent universality and expansibility, and has advantages in volume and weight for airborne platform, so it can meet the requirements of control system of the integrated airborne multispectral imaging system. The embedded computer controls the camera parameters setting, filter wheel and stabilized platform working, image and POS data acquisition, and stores the image and data. The airborne multispectral imaging system can connect peripheral device use the ports of the embedded computer, so the system operation and the stored image data management are easy. This airborne multispectral imaging system has advantages of small volume, multi-function, and good expansibility. The imaging experiment results show that this system has potential for multispectral remote sensing in applications such as resource investigation and environmental monitoring.

  9. Aircraft and satellite remote sensing of desert soils and landscapes

    Science.gov (United States)

    Petersen, G. W.; Connors, K. F.; Miller, D. A.; Day, R. L.; Gardner, T. W.

    1987-01-01

    Remote sensing data on desert soils and landscapes, obtained by the Landsat TM, Heat Capacity Mapping Mission (HCMM), Simulated SPOT, and Thermal IR Multispectral Scanner (TIMS) aboard an aircraft, are discussed together with the analytical techniques used in the studies. The TM data for southwestern Nevada were used to discriminate among the alluvial fan deposits with different degrees of desert pavement and varnish, and different vegetation cover. Thermal-IR data acquired from the HCMM satellite were used to map the spatial distribution of diurnal surface temperatures and to estimate mean annual soil temperatures in central Utah. Simulated SPOT data for northwestern New Mexico identified geomorphic features, such as differences in eolian sand cover and fluvial incision, while the TIMS data depicted surface geologic features of the Saline Valley in California.

  10. Feasibility study and quality assessment of unmanned aircraft system-derived multispectral images

    Science.gov (United States)

    Chang, Kuo-Jen

    2017-04-01

    The purpose of study is to explore the precision and the applicability of UAS-derived multispectral images. In this study, the Micro-MCA6 multispectral camera was mounted on quadcopter. The Micro-MCA6 shoot images synchronized of each single band. By means of geotagged images and control points, the orthomosaic images of each single band generated firstly by 14cm resolution. The multispectral image was merged complete with 6 bands. In order to improve the spatial resolution, the 6 band image fused with 9cm resolution image taken from RGB camera. Quality evaluation of the image is verified of the each single band by using control points and check points. The standard deviations of errors are within 1 to 2 pixel resolution of each band. The quality of the multispectral image is compared with 3 cm resolution orthomosaic RGB image gathered from UAV in the same mission, as well. The standard deviations of errors are within 2 to 3 pixel resolution. The result shows that the errors resulting from the blurry and the band dislocation of the objects edge identification. To the end, the normalized difference vegetation index (NDVI) extracted from the image to explore the condition of vegetation and the nature of the environment. This study demonstrates the feasibility and the capability of the high resolution multispectral images.

  11. POTENTIAL OF UAV-BASED LASER SCANNER AND MULTISPECTRAL CAMERA DATA IN BUILDING INSPECTION

    Directory of Open Access Journals (Sweden)

    D. Mader

    2016-06-01

    Full Text Available Conventional building inspection of bridges, dams or large constructions in general is rather time consuming and often cost expensive due to traffic closures and the need of special heavy vehicles such as under-bridge inspection units or other large lifting platforms. In consideration that, an unmanned aerial vehicle (UAV will be more reliable and efficient as well as less expensive and simpler to operate. The utilisation of UAVs as an assisting tool in building inspections is obviously. Furthermore, light-weight special sensors such as infrared and thermal cameras as well as laser scanner are available and predestined for usage on unmanned aircraft systems. Such a flexible low-cost system is realized in the ADFEX project with the goal of time-efficient object exploration, monitoring and damage detection. For this purpose, a fleet of UAVs, equipped with several sensors for navigation, obstacle avoidance and 3D object-data acquisition, has been developed and constructed. This contribution deals with the potential of UAV-based data in building inspection. Therefore, an overview of the ADFEX project, sensor specifications and requirements of building inspections in general are given. On the basis of results achieved in practical studies, the applicability and potential of the UAV system in building inspection will be presented and discussed.

  12. A summary of the test procedures and operational details of an ocean dumping pollution monitoring experiment conducted 7 October 1976

    Science.gov (United States)

    Hypes, W. D.; Wallace, J. W.; Gurganus, E. A.

    1977-01-01

    A remote sensor experiment was conducted at a sewage sludge dump site off the Delaware/Maryland coast. Two aircraft serving as remote sensor platforms flew over the dump site during a sludge dump. One aircraft carried a multispectral scanner and the other aircraft carried a rapid scanning spectrometer. Data from sea-truth stations were collected concurrent with overpasses of the aircraft. All sensors were operational and produced good digital data.

  13. Remote detection of canopy water stress in coniferous forests using the NS001 Thematic Mapper Simulator and the thermal infrared multispectral scanner

    Science.gov (United States)

    Pierce, Lars L.; Running, Steven W.; Riggs, George A.

    1990-01-01

    Water stress was induced in two coniferous forest stands in West Germany by severing tree sapwood. Leaf water potential, Psi(L), measurements indicated that maximum, naturally occurring levels of water stress developed in the stressed plots while control plots exhibited natural diurnal trends. Images of each site were obtained with the Thematic Mapper Simulator (NS001) and the Thermal Infrared Multispectral Scanner (TIMS) 12 to 15 days after stress induction. NS001 bands 2 to 6, NS001 indices combining bands 4 and 6, and NS001 and TIMS thermal bands showed significant radiance differences between stressed and control plots when large differences in Psi(L) and relative water content (RWC) existed during the morning overflights at Munich. However, the NS001 and TIMS sensors could not detect the slightly smaller differences in Psi(L) and RWC during the Munich afternoon and Frankfurt overflights. The results suggest that routine detection of canopy water stress under operational conditions is difficult utilizing current sensor technology.

  14. Potential utility of the thematic mapper for surface mine monitoring

    International Nuclear Information System (INIS)

    Irons, J.R.; Lachowski, H.M.

    1981-01-01

    One of many potential applications of the thematic mapper (TM) is surface mine monitoring. To assess this potential, data acquired by an aircraft multispectral scanner over Pennsylvania surface mines were preprocessed to simulate the anticipated spectral, spatial, and radiometric characteristics of TM data. False color imagery and thematic maps were derived from the simulated data and compared to imagery and maps derived from LANDSAT multispectral scanner subsystems data. On the basis of this comparison, TM data should definitely increase the detail and accuracy of remotely acquired surface mine information and may enable the remote determination of compliance with reclamation regulations

  15. Use of airborne multispectral scanner data to map alteration related to roll-front uranium migration

    International Nuclear Information System (INIS)

    Peters, D.C.

    1983-01-01

    Computer-enhanced airborne multispectral scanner (MSS) images have been used to detect and map red oxidized alteration related to roll-front uranium migration in the southern Powder River basin, Wyoming. Information in the 0.4- to 1.1-μm spectral region was used to produce a color ratio composite image, upon which the red-altered areas can be differentiated. The red-altered and incipiently altered sandstones result from the migration of a roll-front (or geochemical cell) through the sandstone in the direction of the hydrologic gradient. Most uranium deposits in the Powder River basin occur at the boundary between this oxidized sandstone and reduced sandstone. Therefore, the ability to detect and map this alteration reliably can provide important information about the potential for uranium mineralization down gradient from the altered areas, at the surface in an area of interest. Spectral reflectance studies indicate that a shift in the absorption band edge from 0.52 μm (for goethitic sandstone) to 0.58 μm (for hematitic sandstone) and an intensification of an absorption band at 0.85 μm (for hematitic sandstone) are the bases for identifying the red-altered sandstone as green anomalous areas on the color ratio composite image. Some of the incipiently altered sandstone also appears green, whereas unaltered material and white-altered sandstone appear as blue to cyan colors. Therefore, the composite image is useful in discriminating hematitic sandstone from goethitic sandstone. At high densities (>65%), vegetation masks the sandstones on the color ratio composite image. Artemisia tridentata (sage) and Stipa comata (grass) are the species that have the greatest individual effect on the image

  16. Application of computer processed multispectral data to the discrimination of land collapse (sinkhole) prone areas in Florida

    Science.gov (United States)

    Coker, A. E.; Marshall, R.; Thomson, N. S.

    1977-01-01

    Data were collected near Bartow, Florida, for the purpose of studying land collapse phenomena using remote sensing techniques. Data obtained using the multispectral scanner system consisted of various combinations of 18 spectral bands ranging from 0.4-14.0 microns and several types of photography. The multispectral data were processed on a special-purpose analog computer in order to detect moisture-stressed vegetation and to enhance terrain surface temperatures. The processed results were printed on film to show the patterns of distribution of the proposed hydrogeologic indicators.

  17. Extension of ERIM multispectral data processing capabilities through improved data handling techniques

    Science.gov (United States)

    Kriegler, F. J.

    1973-01-01

    The improvement and extension of the capabilities of the Environmental Research Institute of Michigan processing facility in handling multispectral data are discussed. Improvements consisted of implementing hardware modifications which permitted more rapid access to the recorded data through improved numbering and indexing of such data. In addition, techniques are discussed for handling data from sources other than the ERIM M-5 and M-7 scanner systems.

  18. The composite sequential clustering technique for analysis of multispectral scanner data

    Science.gov (United States)

    Su, M. Y.

    1972-01-01

    The clustering technique consists of two parts: (1) a sequential statistical clustering which is essentially a sequential variance analysis, and (2) a generalized K-means clustering. In this composite clustering technique, the output of (1) is a set of initial clusters which are input to (2) for further improvement by an iterative scheme. This unsupervised composite technique was employed for automatic classification of two sets of remote multispectral earth resource observations. The classification accuracy by the unsupervised technique is found to be comparable to that by traditional supervised maximum likelihood classification techniques. The mathematical algorithms for the composite sequential clustering program and a detailed computer program description with job setup are given.

  19. Multispectral Imaging in Cultural Heritage Conservation

    Science.gov (United States)

    Del Pozo, S.; Rodríguez-Gonzálvez, P.; Sánchez-Aparicio, L. J.; Muñoz-Nieto, A.; Hernández-López, D.; Felipe-García, B.; González-Aguilera, D.

    2017-08-01

    This paper sums up the main contribution derived from the thesis entitled "Multispectral imaging for the analysis of materials and pathologies in civil engineering, constructions and natural spaces" awarded by CIPA-ICOMOS for its connection with the preservation of Cultural Heritage. This thesis is framed within close-range remote sensing approaches by the fusion of sensors operating in the optical domain (visible to shortwave infrared spectrum). In the field of heritage preservation, multispectral imaging is a suitable technique due to its non-destructive nature and its versatility. It combines imaging and spectroscopy to analyse materials and land covers and enables the use of a variety of different geomatic sensors for this purpose. These sensors collect both spatial and spectral information for a given scenario and a specific spectral range, so that, their smaller storage units save the spectral properties of the radiation reflected by the surface of interest. The main goal of this research work is to characterise different construction materials as well as the main pathologies of Cultural Heritage elements by combining active and passive sensors recording data in different ranges. Conclusions about the suitability of each type of sensor and spectral range are drawn in relation to each particular case study and damage. It should be emphasised that results are not limited to images, since 3D intensity data from laser scanners can be integrated with 2D data from passive sensors obtaining high quality products due to the added value that metric brings to multispectral images.

  20. MULTISPECTRAL IMAGING IN CULTURAL HERITAGE CONSERVATION

    Directory of Open Access Journals (Sweden)

    S. Del Pozo

    2017-08-01

    Full Text Available This paper sums up the main contribution derived from the thesis entitled "Multispectral imaging for the analysis of materials and pathologies in civil engineering, constructions and natural spaces" awarded by CIPA-ICOMOS for its connection with the preservation of Cultural Heritage. This thesis is framed within close-range remote sensing approaches by the fusion of sensors operating in the optical domain (visible to shortwave infrared spectrum. In the field of heritage preservation, multispectral imaging is a suitable technique due to its non-destructive nature and its versatility. It combines imaging and spectroscopy to analyse materials and land covers and enables the use of a variety of different geomatic sensors for this purpose. These sensors collect both spatial and spectral information for a given scenario and a specific spectral range, so that, their smaller storage units save the spectral properties of the radiation reflected by the surface of interest. The main goal of this research work is to characterise different construction materials as well as the main pathologies of Cultural Heritage elements by combining active and passive sensors recording data in different ranges. Conclusions about the suitability of each type of sensor and spectral range are drawn in relation to each particular case study and damage. It should be emphasised that results are not limited to images, since 3D intensity data from laser scanners can be integrated with 2D data from passive sensors obtaining high quality products due to the added value that metric brings to multispectral images.

  1. Application of EREP, LANDSAT, and aircraft image data to environmental problems related to coal mining

    Science.gov (United States)

    Amato, R. V.; Russell, O. R.; Martin, K. R.; Wier, C. E.

    1975-01-01

    Remote sensing techniques were used to study coal mining sites within the Eastern Interior Coal Basin (Indiana, Illinois, and western Kentucky), the Appalachian Coal Basin (Ohio, West Virginia, and Pennsylvania) and the anthracite coal basins of northeastern Pennsylvania. Remote sensor data evaluated during these studies were acquired by LANDSAT, Skylab and both high and low altitude aircraft. Airborne sensors included multispectral scanners, multiband cameras and standard mapping cameras loaded with panchromatic, color and color infrared films. The research conducted in these areas is a useful prerequisite to the development of an operational monitoring system that can be peridically employed to supply state and federal regulatory agencies with supportive data. Further research, however, must be undertaken to systematically examine those mining processes and features that can be monitored cost effectively using remote sensors and for determining what combination of sensors and ground sampling processes provide the optimum combination for an operational system.

  2. Nimbus 7 Coastal Zone Color Scanner (CZCS). Level 1 data product users' guide

    Science.gov (United States)

    Williams, S. P.; Szajna, E. F.; Hovis, W. A.

    1985-01-01

    The coastal zone color scanner (CZCS) is a scanning multispectral radiometer designed specifically for the remote sensing of Ocean Color parameters from an Earth orbiting space platform. A technical manual which is intended for users of NIMBUS 7 CZCS Level 1 data products is presented. It contains information needed by investigators and data processing personnel to operate on the data using digital computers and related equipment.

  3. Daytime multispectral scanner aerial surveys of the Oak Ridge Reservation, 1992--1994: Overview of data processing and analysis by the Environmental Restoration Remote Sensing Program, Fiscal year 1995

    International Nuclear Information System (INIS)

    Smyre, J.L.; Hodgson, M.E.; Moll, B.W.; King, A.L.; Cheng, Yang.

    1995-11-01

    Environmental Restoration (ER) Remote Sensing and Special Surveys Program was in 1992 to apply the benefits of remote sensing technologies to Environmental Restoration Management (ERWM) programs at all of the five United States Department of Energy facilities operated and managed by Martin Marietta Energy Systems, Inc. (now Lockheed Martin Energy Systems)-the three Oak Ridge Reservation (ORR) facilities, the Paducah Gaseous Diffusion Plant (PGDP), the Portsmouth Gaseous Diffusion Plant (PORTS)-and adjacent off-site areas. The Remote Sensing Program includes the management of routine and special surveys at these sites, application of state-of-the-art remote sensing and geophysical technologies, and data transformation, integration, and analyses required to make the information valuable to ER. Remotely-sensed data collected of the ORR include natural color and color infrared (IR) aerial photography, 12-band multispectral scanner imagery, predawn thermal IR sensor imagery, magnetic and electromagnetic geophysical surveys, and gamma radiological data

  4. Capability Assessment and Performance Metrics for the Titan Multispectral Mapping Lidar

    Directory of Open Access Journals (Sweden)

    Juan Carlos Fernandez-Diaz

    2016-11-01

    Full Text Available In this paper we present a description of a new multispectral airborne mapping light detection and ranging (lidar along with performance results obtained from two years of data collection and test campaigns. The Titan multiwave lidar is manufactured by Teledyne Optech Inc. (Toronto, ON, Canada and emits laser pulses in the 1550, 1064 and 532 nm wavelengths simultaneously through a single oscillating mirror scanner at pulse repetition frequencies (PRF that range from 50 to 300 kHz per wavelength (max combined PRF of 900 kHz. The Titan system can perform simultaneous mapping in terrestrial and very shallow water environments and its multispectral capability enables new applications, such as the production of false color active imagery derived from the lidar return intensities and the automated classification of target and land covers. Field tests and mapping projects performed over the past two years demonstrate capabilities to classify five land covers in urban environments with an accuracy of 90%, map bathymetry under more than 15 m of water, and map thick vegetation canopies at sub-meter vertical resolutions. In addition to its multispectral and performance characteristics, the Titan system is designed with several redundancies and diversity schemes that have proven to be beneficial for both operations and the improvement of data quality.

  5. Nimbus 7 Coastal Zone Color Scanner (CZCS). Level 2 data product users' guide

    Science.gov (United States)

    Williams, S. P.; Szajna, E. F.; Hovis, W. A.

    1985-01-01

    The coastal zone color scanner (CZCS) is a scanning multispectral radiometer designed for the remote sensing of ocean color parameters from an earth orbiting space platform. A Technical Manual was designed for users of NIMBUS 7 CZCS Level 2 data products. It contains information which describes how the Level 1 data was process to obtain the Level 2 (derived) product. It contains information needed to operate on the data using digital computers and related equipment.

  6. Shifts in Forest Structure in Northwest Montana from 1972 to 2015 Using the Landsat Archive from Multispectral Scanner to Operational Land Imager

    Directory of Open Access Journals (Sweden)

    Shannon L. Savage

    2018-03-01

    Full Text Available There is a pressing need to map changes in forest structure from the earliest time period possible given forest management policies and accelerated disturbances from climate change. The availability of Landsat data from over four decades helps researchers study an ecologically meaningful length of time. Forest structure is most often mapped utilizing lidar data, however these data are prohibitively expensive and cover a narrow temporal window relative to the Landsat archive. Here we describe a technique to use the entire length of the Landsat archive from Multispectral Scanner to Operational Land Imager (M2O to produce three novel outcomes: (1 we used the M2O dataset and standard change vector analysis methods to classify annual forest structure in northwestern Montana from 1972 to 2015, (2 we improved the accuracy of each yearly forest structure classification by applying temporal continuity rules to the whole time series, with final accuracies ranging from 97% to 68% respectively for two and six-category classifications, and (3 we demonstrated the importance of pre-1984 Landsat data for long-term change studies. As the Landsat program continues to acquire Earth imagery into the foreseeable future, time series analyses that aid in classifying forest structure accurately will be key to the success of any land management changes in the future.

  7. An investigative study of multispectral data compression for remotely-sensed images using vector quantization and difference-mapped shift-coding

    Science.gov (United States)

    Jaggi, S.

    1993-01-01

    A study is conducted to investigate the effects and advantages of data compression techniques on multispectral imagery data acquired by NASA's airborne scanners at the Stennis Space Center. The first technique used was vector quantization. The vector is defined in the multispectral imagery context as an array of pixels from the same location from each channel. The error obtained in substituting the reconstructed images for the original set is compared for different compression ratios. Also, the eigenvalues of the covariance matrix obtained from the reconstructed data set are compared with the eigenvalues of the original set. The effects of varying the size of the vector codebook on the quality of the compression and on subsequent classification are also presented. The output data from the Vector Quantization algorithm was further compressed by a lossless technique called Difference-mapped Shift-extended Huffman coding. The overall compression for 7 channels of data acquired by the Calibrated Airborne Multispectral Scanner (CAMS), with an RMS error of 15.8 pixels was 195:1 (0.41 bpp) and with an RMS error of 3.6 pixels was 18:1 (.447 bpp). The algorithms were implemented in software and interfaced with the help of dedicated image processing boards to an 80386 PC compatible computer. Modules were developed for the task of image compression and image analysis. Also, supporting software to perform image processing for visual display and interpretation of the compressed/classified images was developed.

  8. Pattern Decomposition Method and a New Vegetation Index for Hyper-Multispectral Satellite Data Analysis

    Science.gov (United States)

    Muramatsu, K.; Furumi, S.; Hayashi, A.; Shiono, Y.; Ono, A.; Fujiwara, N.; Daigo, M.; Ochiai, F.

    We have developed the ``pattern decomposition method'' based on linear spectral mixing of ground objects for n-dimensional satellite data. In this method, spectral response patterns for each pixel in an image are decomposed into three components using three standard spectral shape patterns determined from the image data. Applying this method to AMSS (Airborne Multi-Spectral Scanner) data, eighteen-dimensional data are successfully transformed into three-dimensional data. Using the three components, we have developed a new vegetation index in which all the multispectral data are reflected. We consider that the index should be linear to the amount of vegetation and vegetation vigor. To validate the index, its relations to vegetation types, vegetation cover ratio, and chlorophyll contents of a leaf were studied using spectral reflectance data measured in the field with a spectrometer. The index was sensitive to vegetation types and vegetation vigor. This method and index are very useful for assessment of vegetation vigor, classifying land cover types and monitoring vegetation changes

  9. Some aspects of adaptive transform coding of multispectral data

    Science.gov (United States)

    Ahmed, N.; Natarajan, T.

    1977-01-01

    This paper concerns a data compression study pertaining to multi-spectral scanner (MSS) data. The motivation for this undertaking is the need for securing data compression of images obtained in connection with the Landsat Follow-On Mission, where a compression of at least 6:1 is required. The MSS data used in this study consisted of four scenes: Tristate, consisting of 256 pels per row and a total of 512 rows - i.e., (256x512), (2) Sacramento (256x512), (3) Portland (256x512), and (4) Bald Knob (200x256). All these scenes were on digital tape at 6 bits/pel. The corresponding reconstructed scenes of 1 bit/pel (i.e., a 6:1 compression) are included.

  10. Comparison of sea-ice freeboard distributions from aircraft data and cryosat-2

    DEFF Research Database (Denmark)

    Ricker, Robert; Hendricks, Stefan; Helm, Veit

    2012-01-01

    highly accurate range measurements. During the CryoSat Validation Experiment (CryoVEx) 2011 in the Lincoln Sea Cryosat-2 underpasses were accomplished with two aircraft which carried an airborne laser scanner, a radar altimeter and an electromagnetic induction device for direct sea ice thickness...... retrieval. Both aircraft flew in close formation at the same time of a CryoSat-2 overpass. This is a study about the comparison of the sea-ice freeboard distribution of laser scanner and radar altimeter measurements with the CryoSat-2 product within the multi-year sea ice region of the Lincoln Sea in spring...

  11. Crop water-stress assessment using an airborne thermal scanner

    Science.gov (United States)

    Millard, J. P.; Jackson, R. D.; Reginato, R. J.; Idso, S. B.; Goettelman, R. C.

    1978-01-01

    An airborne thermal scanner was used to measure the temperature of a wheat crop canopy in Phoenix, Arizona. The results indicate that canopy temperatures acquired about an hour and a half past solar noon were well correlated with presunrise plant water tension, a parameter directly related to plant growth and development. Pseudo-colored thermal images reading directly in stress degree days, a unit indicative of crop irrigation needs and yield potential, were produced. The aircraft data showed significant within-field canopy temperature variability, indicating the superiority of the synoptic view provided by aircraft over localized ground measurements. The standard deviation between airborne and ground-acquired canopy temperatures was 2 C or less.

  12. Appendix C: A comparative study of small scale remotely sensed data for monitoring clearcutting in hardwood forests. M.S. Thesis; [Allegheny National Forest, Pennsylvania and the Adirondacks, New York

    Science.gov (United States)

    Hafker, W. R.

    1980-01-01

    Manual photointerpretation techniques were used to analyze images acquired by high altitude aircraft, the Skylab multispectral and Earth terrain camera (ETC), the LANDSAT multispectral scanner, and the LANDSAT-3 return beam vidicon camera. A color-additive viewer, and digital image analysis were also used on the LANDSAT MSS imagery. The value of each type of remotely sensed data was judged by the ease and accuracy of clearcut identification, and by the amount of detail discernible, especially regarding revegetation. Results of a site study in the Allegheny National Forest, Pennsylvania indicate that high altitude aerial photography, especially color infrared photography acquired during the growing season, is well suited for identifying clearcuts and assessing revegetation. Although photographs acquired with Skylab's ETC also yielded good results, only incomplete inventories of clearcuts could be made using LANDSAT imagery. Results for the Adirondack region of New York State were similar for the aircraft and satellite photography, but even less satisfactory for the LANDSAT imagery.

  13. Radiometric calibration of the reflective bands of NS001-Thematic Mapper Simulator (TMS) and modular multispectral radiometers (MMR)

    Science.gov (United States)

    Markham, Brian L.; Wood, Frank M., Jr.; Ahmad, Suraiya P.

    1988-01-01

    The NS001 Thematic Mapper Simulator scanner (TMS) and several modular multispectral radiometers (MMRs) are among the primary instruments used in the First ISLSCP (International Satellite Land Surface Climatology Project) Field Experiment (FIFE). The NS001 has a continuously variable gain setting. Calibration of the NS001 data is influenced by drift in the dark current level of up to six counts during a mirror scan at typical gain settings. The MMR instruments are being used in their 1 deg FOV configuration on the helicopter and 15 deg FOV on the ground.

  14. TESTING OF LAND COVER CLASSIFICATION FROM MULTISPECTRAL AIRBORNE LASER SCANNING DATA

    Directory of Open Access Journals (Sweden)

    K. Bakuła

    2016-06-01

    Full Text Available Multispectral Airborne Laser Scanning provides a new opportunity for airborne data collection. It provides high-density topographic surveying and is also a useful tool for land cover mapping. Use of a minimum of three intensity images from a multiwavelength laser scanner and 3D information included in the digital surface model has the potential for land cover/use classification and a discussion about the application of this type of data in land cover/use mapping has recently begun. In the test study, three laser reflectance intensity images (orthogonalized point cloud acquired in green, near-infrared and short-wave infrared bands, together with a digital surface model, were used in land cover/use classification where six classes were distinguished: water, sand and gravel, concrete and asphalt, low vegetation, trees and buildings. In the tested methods, different approaches for classification were applied: spectral (based only on laser reflectance intensity images, spectral with elevation data as additional input data, and spectro-textural, using morphological granulometry as a method of texture analysis of both types of data: spectral images and the digital surface model. The method of generating the intensity raster was also tested in the experiment. Reference data were created based on visual interpretation of ALS data and traditional optical aerial and satellite images. The results have shown that multispectral ALS data are unlike typical multispectral optical images, and they have a major potential for land cover/use classification. An overall accuracy of classification over 90% was achieved. The fusion of multi-wavelength laser intensity images and elevation data, with the additional use of textural information derived from granulometric analysis of images, helped to improve the accuracy of classification significantly. The method of interpolation for the intensity raster was not very helpful, and using intensity rasters with both first and

  15. Weed detection using unmanned aircraft vehicles

    Directory of Open Access Journals (Sweden)

    Pflanz, Michael

    2014-03-01

    Full Text Available In contrast to agricultural remote sensing technologies, which are based on images from satellites or manned aircrafts, photogrammetry at low altitude from unmanned aircraft vehicles lead to higher spatial resolution, real-time processing and lower costs. Moreover multicopter aircrafts are suitable vehicles to perform precise path or stationary flights. In terms of vegetation photogrammetry this minimises motion blur and provide better image overlapping for stitching and mapping procedures. Through improved image analyses and through the recent increase in the availability of powerful batteries, microcontrollers and multispectral cameras, it can be expected in future that spatial mapping of weeds from low altitudes will be promoted. A small unmanned aircraft vehicle with a modified RGB camera was tested taking images from agricultural fields. A microcopter with six rotors was applied. The hexacopter in particular is GPS controlled and operates within predefined areas at given altitudes (from 5 to 10 m. Different scenarios of photogrammetrically weed detection have been carried out regarding to variable altitude, image resolution, weed and crop growth stages. First experiences with microcopter showed a high potential for site-specific weed control. Images analyses with regards to recognition of weed patches can be used to adapt herbicide applications to varying weed occurrence across a field.

  16. Spectral signature selection for mapping unvegetated soils

    Science.gov (United States)

    May, G. A.; Petersen, G. W.

    1975-01-01

    Airborne multispectral scanner data covering the wavelength interval from 0.40-2.60 microns were collected at an altitude of 1000 m above the terrain in southeastern Pennsylvania. Uniform training areas were selected within three sites from this flightline. Soil samples were collected from each site and a procedure developed to allow assignment of scan line and element number from the multispectral scanner data to each sampling location. These soil samples were analyzed on a spectrophotometer and laboratory spectral signatures were derived. After correcting for solar radiation and atmospheric attenuation, the laboratory signatures were compared to the spectral signatures derived from these same soils using multispectral scanner data. Both signatures were used in supervised and unsupervised classification routines. Computer-generated maps using the laboratory and multispectral scanner derived signatures resulted in maps that were similar to maps resulting from field surveys. Approximately 90% agreement was obtained between classification maps produced using multispectral scanner derived signatures and laboratory derived signatures.

  17. MULTISPECTRAL AIRBORNE LASER SCANNING - A NEW TREND IN THE DEVELOPMENT OF LIDAR TECHNOLOGY

    Directory of Open Access Journals (Sweden)

    Bakuła Krzysztof

    2015-12-01

    Full Text Available Airborne laser scanning (ALS is the one of the most accurate remote sensing techniques for data acquisition where the terrain and its coverage is concerned. Modern scanners have been able to scan in two or more channels (frequencies of the laser recently. This gives the rise to the possibility of obtaining diverse information about an area with the different spectral properties of objects. The paper presents an example of a multispectral ALS system - Titan by Optech - with the possibility of data including the analysis of digital elevation models accuracy and data density. As a result of the study, the high relative accuracy of LiDAR acquisition in three spectral bands was proven. The mean differences between digital terrain models (DTMs were less than 0.03 m. The data density analysis showed the influence of the laser wavelength. The points clouds that were tested had average densities of 25, 23 and 20 points per square metre respectively for green (G, near-infrared (NIR and shortwave-infrared (SWIR lasers. In this paper, the possibility of the generation of colour composites using orthoimages of laser intensity reflectance and its classification capabilities using data from airborne multispectral laser scanning for land cover mapping are also discussed and compared with conventional photogrammetric techniques.

  18. Aircraft versus spacecraft for remote monitoring of water quality in U.S. coastal zones

    Science.gov (United States)

    Darnell, W. L.

    1977-01-01

    To provide guidance for conducting future water monitoring missions over U.S. coasts, aircraft and spacecraft approaches were defined and quantitatively compared. Sensors, aircraft and spacecraft were selected from current or developmental types for the hardware concepts and monitoring was assumed to begin in 1981-1983. Comparative data are presented on capabilities and costs to monitor both recognized pollution sites and broad shelf areas. For these mission requirements, a large fleet of light aircraft provided better coverage and at lower costs generally than one spacecraft, assuming a single, multi-spectral sensor on each platform. This result could change, however, should additional useful sensors with low cost penalties be found for the spacecraft.

  19. Remote sensing for vineyard management

    Science.gov (United States)

    Philipson, W. R.; Erb, T. L.; Fernandez, D.; Mcleester, J. N.

    1980-01-01

    Cornell's Remote Sensing Program has been involved in a continuing investigation to assess the value of remote sensing for vineyard management. Program staff members have conducted a series of site and crop analysis studies. These include: (1) panchromatic aerial photography for planning artificial drainage in a new vineyard; (2) color infrared aerial photography for assessing crop vigor/health; and (3) color infrared aerial photography and aircraft multispectral scanner data for evaluating yield related factors. These studies and their findings are reviewed.

  20. CLASSIFICATION BY USING MULTISPECTRAL POINT CLOUD DATA

    Directory of Open Access Journals (Sweden)

    C. T. Liao

    2012-07-01

    Full Text Available Remote sensing images are generally recorded in two-dimensional format containing multispectral information. Also, the semantic information is clearly visualized, which ground features can be better recognized and classified via supervised or unsupervised classification methods easily. Nevertheless, the shortcomings of multispectral images are highly depending on light conditions, and classification results lack of three-dimensional semantic information. On the other hand, LiDAR has become a main technology for acquiring high accuracy point cloud data. The advantages of LiDAR are high data acquisition rate, independent of light conditions and can directly produce three-dimensional coordinates. However, comparing with multispectral images, the disadvantage is multispectral information shortage, which remains a challenge in ground feature classification through massive point cloud data. Consequently, by combining the advantages of both LiDAR and multispectral images, point cloud data with three-dimensional coordinates and multispectral information can produce a integrate solution for point cloud classification. Therefore, this research acquires visible light and near infrared images, via close range photogrammetry, by matching images automatically through free online service for multispectral point cloud generation. Then, one can use three-dimensional affine coordinate transformation to compare the data increment. At last, the given threshold of height and color information is set as threshold in classification.

  1. Classification by Using Multispectral Point Cloud Data

    Science.gov (United States)

    Liao, C. T.; Huang, H. H.

    2012-07-01

    Remote sensing images are generally recorded in two-dimensional format containing multispectral information. Also, the semantic information is clearly visualized, which ground features can be better recognized and classified via supervised or unsupervised classification methods easily. Nevertheless, the shortcomings of multispectral images are highly depending on light conditions, and classification results lack of three-dimensional semantic information. On the other hand, LiDAR has become a main technology for acquiring high accuracy point cloud data. The advantages of LiDAR are high data acquisition rate, independent of light conditions and can directly produce three-dimensional coordinates. However, comparing with multispectral images, the disadvantage is multispectral information shortage, which remains a challenge in ground feature classification through massive point cloud data. Consequently, by combining the advantages of both LiDAR and multispectral images, point cloud data with three-dimensional coordinates and multispectral information can produce a integrate solution for point cloud classification. Therefore, this research acquires visible light and near infrared images, via close range photogrammetry, by matching images automatically through free online service for multispectral point cloud generation. Then, one can use three-dimensional affine coordinate transformation to compare the data increment. At last, the given threshold of height and color information is set as threshold in classification.

  2. Multispectral recordings and analysis of psoriasis lesions

    DEFF Research Database (Denmark)

    Clemmensen, Line Katrine Harder; Ersbøll, Bjarne Kjær

    2006-01-01

    An objective method to evaluate the severeness of psoriasis lesions is proposed. In order to obtain objectivity multi-spectral imaging is used. The multi-spectral images give rise to a large p, small n problem which is solved by use of elastic net model selection. The method is promising for furt......An objective method to evaluate the severeness of psoriasis lesions is proposed. In order to obtain objectivity multi-spectral imaging is used. The multi-spectral images give rise to a large p, small n problem which is solved by use of elastic net model selection. The method is promising...

  3. Analysis of Eocene depositional environments - Preliminary TM and TIMS results, Wind River Basin, Wyoming

    Science.gov (United States)

    Stucky, Richard K.; Krishtalka, Leonard; Redline, Andrew D.; Lang, Harold R.

    1987-01-01

    Both Landsat TM and aircraft Thermal IR Multispectral Scanner (TIMS) data have been used to map the lithofacies of the Wind River Basin's Eocene physical and biological environments. Preliminary analyses of these data have furnished maps of a fault contact boundary and a complex network of fluvial ribbon channel sandstones. The synoptic view thereby emerging for Eocene fluvial facies clarifies the relationships of ribbon channel sandstones to fossil-bearing overbank/floodplain facies and certain peleosols. The utility of TM and TIMS data is thereby demonstrated.

  4. Side scanner for supermarkets: a new scanner design standard

    Science.gov (United States)

    Cheng, Charles K.; Cheng, J. K.

    1996-09-01

    High speed UPC bar code has become a standard mode of data capture for supermarkets in the US, Europe, and Japan. The influence of the ergonomics community on the design of the scanner is evident. During the past decade the ergonomic issues of cashier in check-outs has led to occupational hand-wrist cumulative trauma disorders, in most cases causing carpal tunnel syndrome, a permanent hand injury. In this paper, the design of a side scanner to resolve the issues is discussed. The complex optical module and the sensor for aforesaid side scanner is described. The ergonomic advantages offer the old counter mounted vertical scanner has been experimentally proved by the industrial funded study at an independent university.

  5. Multispectral imaging for biometrics

    Science.gov (United States)

    Rowe, Robert K.; Corcoran, Stephen P.; Nixon, Kristin A.; Ostrom, Robert E.

    2005-03-01

    Automated identification systems based on fingerprint images are subject to two significant types of error: an incorrect decision about the identity of a person due to a poor quality fingerprint image and incorrectly accepting a fingerprint image generated from an artificial sample or altered finger. This paper discusses the use of multispectral sensing as a means to collect additional information about a finger that significantly augments the information collected using a conventional fingerprint imager based on total internal reflectance. In the context of this paper, "multispectral sensing" is used broadly to denote a collection of images taken under different polarization conditions and illumination configurations, as well as using multiple wavelengths. Background information is provided on conventional fingerprint imaging. A multispectral imager for fingerprint imaging is then described and a means to combine the two imaging systems into a single unit is discussed. Results from an early-stage prototype of such a system are shown.

  6. Multispectral Palmprint Recognition Using a Quaternion Matrix

    Directory of Open Access Journals (Sweden)

    Yafeng Li

    2012-04-01

    Full Text Available Palmprints have been widely studied for biometric recognition for many years. Traditionally, a white light source is used for illumination. Recently, multispectral imaging has drawn attention because of its high recognition accuracy. Multispectral palmprint systems can provide more discriminant information under different illuminations in a short time, thus they can achieve better recognition accuracy. Previously, multispectral palmprint images were taken as a kind of multi-modal biometrics, and the fusion scheme on the image level or matching score level was used. However, some spectral information will be lost during image level or matching score level fusion. In this study, we propose a new method for multispectral images based on a quaternion model which could fully utilize the multispectral information. Firstly, multispectral palmprint images captured under red, green, blue and near-infrared (NIR illuminations were represented by a quaternion matrix, then principal component analysis (PCA and discrete wavelet transform (DWT were applied respectively on the matrix to extract palmprint features. After that, Euclidean distance was used to measure the dissimilarity between different features. Finally, the sum of two distances and the nearest neighborhood classifier were employed for recognition decision. Experimental results showed that using the quaternion matrix can achieve a higher recognition rate. Given 3000 test samples from 500 palms, the recognition rate can be as high as 98.83%.

  7. Multispectral imaging of wok fried vegetables

    DEFF Research Database (Denmark)

    Løje, Hanne; Dissing, Bjørn Skovlund; Clemmensen, Line Katrine Harder

    2011-01-01

    This paper shows how multispectral images can be used to assess color change over time in wok fried vegetables. We present results where feature selection was performed with sparse methods from the multispectral images to detect the color changes of wok fried carrots and celeriac stored at +5°C...

  8. Object Classification Using Airborne Multispectral LiDAR Data

    Directory of Open Access Journals (Sweden)

    PAN Suoyan

    2018-02-01

    Full Text Available Airborne multispectral LiDAR system,which obtains surface geometry and spectral data of objects,simultaneously,has become a fast effective,large-scale spatial data acquisition method.Multispectral LiDAR data are characteristics of completeness and consistency of spectrum and spatial geometric information.Support vector machine (SVM,a machine learning method,is capable of classifying objects based on small samples.Therefore,by means of SVM,this paper performs land cover classification using multispectral LiDAR data. First,all independent point cloud with different wavelengths are merged into a single point cloud,where each pixel contains the three-wavelength spectral information.Next,the merged point cloud is converted into range and intensity images.Finally,land-cover classification is performed by means of SVM.All experiments were conducted on the Optech Titan multispectral LiDAR data,containing three individual point cloud collected by 532 nm,1024 nm,and 1550 nm laser beams.Experimental results demonstrate that ①compared to traditional single-wavelength LiDAR data,multispectral LiDAR data provide a promising solution to land use and land cover applications;②SVM is a feasible method for land cover classification of multispectral LiDAR data.

  9. Computational multispectral video imaging [Invited].

    Science.gov (United States)

    Wang, Peng; Menon, Rajesh

    2018-01-01

    Multispectral imagers reveal information unperceivable to humans and conventional cameras. Here, we demonstrate a compact single-shot multispectral video-imaging camera by placing a micro-structured diffractive filter in close proximity to the image sensor. The diffractive filter converts spectral information to a spatial code on the sensor pixels. Following a calibration step, this code can be inverted via regularization-based linear algebra to compute the multispectral image. We experimentally demonstrated spectral resolution of 9.6 nm within the visible band (430-718 nm). We further show that the spatial resolution is enhanced by over 30% compared with the case without the diffractive filter. We also demonstrate Vis-IR imaging with the same sensor. Because no absorptive color filters are utilized, sensitivity is preserved as well. Finally, the diffractive filters can be easily manufactured using optical lithography and replication techniques.

  10. Design and development of an airborne multispectral imaging system

    Science.gov (United States)

    Kulkarni, Rahul R.; Bachnak, Rafic; Lyle, Stacey; Steidley, Carl W.

    2002-08-01

    Advances in imaging technology and sensors have made airborne remote sensing systems viable for many applications that require reasonably good resolution at low cost. Digital cameras are making their mark on the market by providing high resolution at very high rates. This paper describes an aircraft-mounted imaging system (AMIS) that is being designed and developed at Texas A&M University-Corpus Christi (A&M-CC) with the support of a grant from NASA. The approach is to first develop and test a one-camera system that will be upgraded into a five-camera system that offers multi-spectral capabilities. AMIS will be low cost, rugged, portable and has its own battery power source. Its immediate use will be to acquire images of the Coastal area in the Gulf of Mexico for a variety of studies covering vast spectra from near ultraviolet region to near infrared region. This paper describes AMIS and its characteristics, discusses the process for selecting the major components, and presents the progress.

  11. Multispectral histogram normalization contrast enhancement

    Science.gov (United States)

    Soha, J. M.; Schwartz, A. A.

    1979-01-01

    A multispectral histogram normalization or decorrelation enhancement which achieves effective color composites by removing interband correlation is described. The enhancement procedure employs either linear or nonlinear transformations to equalize principal component variances. An additional rotation to any set of orthogonal coordinates is thus possible, while full histogram utilization is maintained by avoiding the reintroduction of correlation. For the three-dimensional case, the enhancement procedure may be implemented with a lookup table. An application of the enhancement to Landsat multispectral scanning imagery is presented.

  12. Multispectral analytical image fusion

    International Nuclear Information System (INIS)

    Stubbings, T.C.

    2000-04-01

    With new and advanced analytical imaging methods emerging, the limits of physical analysis capabilities and furthermore of data acquisition quantities are constantly pushed, claiming high demands to the field of scientific data processing and visualisation. Physical analysis methods like Secondary Ion Mass Spectrometry (SIMS) or Auger Electron Spectroscopy (AES) and others are capable of delivering high-resolution multispectral two-dimensional and three-dimensional image data; usually this multispectral data is available in form of n separate image files with each showing one element or other singular aspect of the sample. There is high need for digital image processing methods enabling the analytical scientist, confronted with such amounts of data routinely, to get rapid insight into the composition of the sample examined, to filter the relevant data and to integrate the information of numerous separate multispectral images to get the complete picture. Sophisticated image processing methods like classification and fusion provide possible solution approaches to this challenge. Classification is a treatment by multivariate statistical means in order to extract analytical information. Image fusion on the other hand denotes a process where images obtained from various sensors or at different moments of time are combined together to provide a more complete picture of a scene or object under investigation. Both techniques are important for the task of information extraction and integration and often one technique depends on the other. Therefore overall aim of this thesis is to evaluate the possibilities of both techniques regarding the task of analytical image processing and to find solutions for the integration and condensation of multispectral analytical image data in order to facilitate the interpretation of the enormous amounts of data routinely acquired by modern physical analysis instruments. (author)

  13. Online Multi-Spectral Meat Inspection

    DEFF Research Database (Denmark)

    Nielsen, Jannik Boll; Larsen, Anders Boesen Lindbo

    2013-01-01

    We perform an explorative study on multi-spectral image data from a prototype device developed for fast online quality inspection of meat products. Because the camera setup is built for speed, we sacrifice exact pixel correspondences between the different bands of the multi-spectral images. Our...... work is threefold as we 1) investigate the color distributions and construct a model to describe pork loins, 2) classify the different components in pork loins (meat, fat, membrane), and 3) detect foreign objects on the surface of pork loins. Our investigation shows that the color distributions can...

  14. Color enhancement in multispectral image of human skin

    Science.gov (United States)

    Mitsui, Masanori; Murakami, Yuri; Obi, Takashi; Yamaguchi, Masahiro; Ohyama, Nagaaki

    2003-07-01

    Multispectral imaging is receiving attention in medical color imaging, as high-fidelity color information can be acquired by the multispectral image capturing. On the other hand, as color enhancement in medical color image is effective for distinguishing lesion from normal part, we apply a new technique for color enhancement using multispectral image to enhance the features contained in a certain spectral band, without changing the average color distribution of original image. In this method, to keep the average color distribution, KL transform is applied to spectral data, and only high-order KL coefficients are amplified in the enhancement. Multispectral images of human skin of bruised arm are captured by 16-band multispectral camera, and the proposed color enhancement is applied. The resultant images are compared with the color images reproduced assuming CIE D65 illuminant (obtained by natural color reproduction technique). As a result, the proposed technique successfully visualizes unclear bruised lesions, which are almost invisible in natural color images. The proposed technique will provide support tool for the diagnosis in dermatology, visual examination in internal medicine, nursing care for preventing bedsore, and so on.

  15. Multispectral colormapping using penalized least square regression

    DEFF Research Database (Denmark)

    Dissing, Bjørn Skovlund; Carstensen, Jens Michael; Larsen, Rasmus

    2010-01-01

    The authors propose a novel method to map a multispectral image into the device independent color space CIE-XYZ. This method provides a way to visualize multispectral images by predicting colorvalues from spectral values while maintaining interpretability and is tested on a light emitting diode...... that the interpretability improves significantly but comes at the cost of slightly worse predictability....

  16. Multispectral Image Feature Points

    Directory of Open Access Journals (Sweden)

    Cristhian Aguilera

    2012-09-01

    Full Text Available This paper presents a novel feature point descriptor for the multispectral image case: Far-Infrared and Visible Spectrum images. It allows matching interest points on images of the same scene but acquired in different spectral bands. Initially, points of interest are detected on both images through a SIFT-like based scale space representation. Then, these points are characterized using an Edge Oriented Histogram (EOH descriptor. Finally, points of interest from multispectral images are matched by finding nearest couples using the information from the descriptor. The provided experimental results and comparisons with similar methods show both the validity of the proposed approach as well as the improvements it offers with respect to the current state-of-the-art.

  17. Optimal wavelength band clustering for multispectral iris recognition.

    Science.gov (United States)

    Gong, Yazhuo; Zhang, David; Shi, Pengfei; Yan, Jingqi

    2012-07-01

    This work explores the possibility of clustering spectral wavelengths based on the maximum dissimilarity of iris textures. The eventual goal is to determine how many bands of spectral wavelengths will be enough for iris multispectral fusion and to find these bands that will provide higher performance of iris multispectral recognition. A multispectral acquisition system was first designed for imaging the iris at narrow spectral bands in the range of 420 to 940 nm. Next, a set of 60 human iris images that correspond to the right and left eyes of 30 different subjects were acquired for an analysis. Finally, we determined that 3 clusters were enough to represent the 10 feature bands of spectral wavelengths using the agglomerative clustering based on two-dimensional principal component analysis. The experimental results suggest (1) the number, center, and composition of clusters of spectral wavelengths and (2) the higher performance of iris multispectral recognition based on a three wavelengths-bands fusion.

  18. Design and fabrication of multispectral optics using expanded glass map

    Science.gov (United States)

    Bayya, Shyam; Gibson, Daniel; Nguyen, Vinh; Sanghera, Jasbinder; Kotov, Mikhail; Drake, Gryphon; Deegan, John; Lindberg, George

    2015-06-01

    As the desire to have compact multispectral imagers in various DoD platforms is growing, the dearth of multispectral optics is widely felt. With the limited number of material choices for optics, these multispectral imagers are often very bulky and impractical on several weight sensitive platforms. To address this issue, NRL has developed a large set of unique infrared glasses that transmit from 0.9 to > 14 μm in wavelength and expand the glass map for multispectral optics with refractive indices from 2.38 to 3.17. They show a large spread in dispersion (Abbe number) and offer some unique solutions for multispectral optics designs. The new NRL glasses can be easily molded and also fused together to make bonded doublets. A Zemax compatible glass file has been created and is available upon request. In this paper we present some designs, optics fabrication and imaging, all using NRL materials.

  19. Lossless compression of multispectral images using spectral information

    Science.gov (United States)

    Ma, Long; Shi, Zelin; Tang, Xusheng

    2009-10-01

    Multispectral images are available for different purposes due to developments in spectral imaging systems. The sizes of multispectral images are enormous. Thus transmission and storage of these volumes of data require huge time and memory resources. That is why compression algorithms must be developed. A salient property of multispectral images is that strong spectral correlation exists throughout almost all bands. This fact is successfully used to predict each band based on the previous bands. We propose to use spectral linear prediction and entropy coding with context modeling for encoding multispectral images. Linear prediction predicts the value for the next sample and computes the difference between predicted value and the original value. This difference is usually small, so it can be encoded with less its than the original value. The technique implies prediction of each image band by involving number of bands along the image spectra. Each pixel is predicted using information provided by pixels in the previous bands in the same spatial position. As done in the JPEG-LS, the proposed coder also represents the mapped residuals by using an adaptive Golomb-Rice code with context modeling. This residual coding is context adaptive, where the context used for the current sample is identified by a context quantization function of the three gradients. Then, context-dependent Golomb-Rice code and bias parameters are estimated sample by sample. The proposed scheme was compared with three algorithms applied to the lossless compression of multispectral images, namely JPEG-LS, Rice coding, and JPEG2000. Simulation tests performed on AVIRIS images have demonstrated that the proposed compression scheme is suitable for multispectral images.

  20. High resolution imaging of impacted CFRP composites with a fiber-optic laser-ultrasound scanner

    Directory of Open Access Journals (Sweden)

    Ivan Pelivanov

    2016-06-01

    Full Text Available Damage induced in polymer composites by various impacts must be evaluated to predict a component’s post-impact strength and residual lifetime, especially when impacts occur in structures related to human safety (in aircraft, for example. X-ray tomography is the conventional standard to study an internal structure with high resolution. However, it is of little use when the impacted area cannot be extracted from a structure. In addition, X-ray tomography is expensive and time-consuming. Recently, we have demonstrated that a kHz-rate laser-ultrasound (LU scanner is very efficient both for locating large defects and evaluating the material structure. Here, we show that high-quality images of damage produced by the LU scanner in impacted carbon-fiber reinforced polymer (CFRP composites are similar to those produced by X-ray tomograms; but they can be obtained with only single-sided access to the object under study. Potentially, the LU method can be applied to large components in-situ.

  1. High resolution imaging of impacted CFRP composites with a fiber-optic laser-ultrasound scanner.

    Science.gov (United States)

    Pelivanov, Ivan; Ambroziński, Łukasz; Khomenko, Anton; Koricho, Ermias G; Cloud, Gary L; Haq, Mahmoodul; O'Donnell, Matthew

    2016-06-01

    Damage induced in polymer composites by various impacts must be evaluated to predict a component's post-impact strength and residual lifetime, especially when impacts occur in structures related to human safety (in aircraft, for example). X-ray tomography is the conventional standard to study an internal structure with high resolution. However, it is of little use when the impacted area cannot be extracted from a structure. In addition, X-ray tomography is expensive and time-consuming. Recently, we have demonstrated that a kHz-rate laser-ultrasound (LU) scanner is very efficient both for locating large defects and evaluating the material structure. Here, we show that high-quality images of damage produced by the LU scanner in impacted carbon-fiber reinforced polymer (CFRP) composites are similar to those produced by X-ray tomograms; but they can be obtained with only single-sided access to the object under study. Potentially, the LU method can be applied to large components in-situ.

  2. Complete-arch accuracy of intraoral scanners.

    Science.gov (United States)

    Treesh, Joshua C; Liacouras, Peter C; Taft, Robert M; Brooks, Daniel I; Raiciulescu, Sorana; Ellert, Daniel O; Grant, Gerald T; Ye, Ling

    2018-04-30

    Intraoral scanners have shown varied results in complete-arch applications. The purpose of this in vitro study was to evaluate the complete-arch accuracy of 4 intraoral scanners based on trueness and precision measurements compared with a known reference (trueness) and with each other (precision). Four intraoral scanners were evaluated: CEREC Bluecam, CEREC Omnicam, TRIOS Color, and Carestream CS 3500. A complete-arch reference cast was created and printed using a 3-dimensional dental cast printer with photopolymer resin. The reference cast was digitized using a laboratory-based white light 3-dimensional scanner. The printed reference cast was scanned 10 times with each intraoral scanner. The digital standard tessellation language (STL) files from each scanner were then registered to the reference file and compared with differences in trueness and precision using a 3-dimensional modeling software. Additionally, scanning time was recorded for each scan performed. The Wilcoxon signed rank, Kruskal-Wallis, and Dunn tests were used to detect differences for trueness, precision, and scanning time (α=.05). Carestream CS 3500 had the lowest overall trueness and precision compared with Bluecam and TRIOS Color. The fourth scanner, Omnicam, had intermediate trueness and precision. All of the scanners tended to underestimate the size of the reference file, with exception of the Carestream CS 3500, which was more variable. Based on visual inspection of the color rendering of signed differences, the greatest amount of error tended to be in the posterior aspects of the arch, with local errors exceeding 100 μm for all scans. The single capture scanner Carestream CS 3500 had the overall longest scan times and was significantly slower than the continuous capture scanners TRIOS Color and Omnicam. Significant differences in both trueness and precision were found among the scanners. Scan times of the continuous capture scanners were faster than the single capture scanners

  3. Reproducible high-resolution multispectral image acquisition in dermatology

    Science.gov (United States)

    Duliu, Alexandru; Gardiazabal, José; Lasser, Tobias; Navab, Nassir

    2015-07-01

    Multispectral image acquisitions are increasingly popular in dermatology, due to their improved spectral resolution which enables better tissue discrimination. Most applications however focus on restricted regions of interest, imaging only small lesions. In this work we present and discuss an imaging framework for high-resolution multispectral imaging on large regions of interest.

  4. Multispectral Imaging for Determination of Astaxanthin Concentration in Salmonids

    DEFF Research Database (Denmark)

    Dissing, Bjørn Skovlund; Nielsen, Michael Engelbrecht; Ersbøll, Bjarne Kjær

    2011-01-01

    Multispectral imaging has been evaluated for characterization of the concentration of a specific cartenoid pigment; astaxanthin. 59 fillets of rainbow trout, Oncorhynchus mykiss, were filleted and imaged using a rapid multispectral imaging device for quantitative analysis. The multispectral imaging...... device captures reflection properties in 19 distinct wavelength bands, prior to determination of the true concentration of astaxanthin. The samples ranged from 0.20 to 4.34 mu g per g fish. A PLSR model was calibrated to predict astaxanthin concentration from novel images, and showed good results...... concentration in rainbow trout fillets....

  5. Compact multispectral photodiode arrays using micropatterned dichroic filters

    Science.gov (United States)

    Chandler, Eric V.; Fish, David E.

    2014-05-01

    The next generation of multispectral instruments requires significant improvements in both spectral band customization and portability to support the widespread deployment of application-specific optical sensors. The benefits of spectroscopy are well established for numerous applications including biomedical instrumentation, industrial sorting and sensing, chemical detection, and environmental monitoring. In this paper, spectroscopic (and by extension hyperspectral) and multispectral measurements are considered. The technology, tradeoffs, and application fits of each are evaluated. In the majority of applications, monitoring 4-8 targeted spectral bands of optimized wavelength and bandwidth provides the necessary spectral contrast and correlation. An innovative approach integrates precision spectral filters at the photodetector level to enable smaller sensors, simplify optical designs, and reduce device integration costs. This method supports user-defined spectral bands to create application-specific sensors in a small footprint with scalable cost efficiencies. A range of design configurations, filter options and combinations are presented together with typical applications ranging from basic multi-band detection to stringent multi-channel fluorescence measurement. An example implementation packages 8 narrowband silicon photodiodes into a 9x9mm ceramic LCC (leadless chip carrier) footprint. This package is designed for multispectral applications ranging from portable color monitors to purpose- built OEM industrial and scientific instruments. Use of an eight-channel multispectral photodiode array typically eliminates 10-20 components from a device bill-of-materials (BOM), streamlining the optical path and shrinking the footprint by 50% or more. A stepwise design approach for multispectral sensors is discussed - including spectral band definition, optical design tradeoffs and constraints, and device integration from prototype through scalable volume production

  6. Performing and updating an inventory of Oregon's expanding irrigated agricultural lands utilizing remote sensing technology

    Science.gov (United States)

    Hall, M. J.

    1981-01-01

    An inventory technique based upon using remote sensing technology, interpreting both high altitude aerial photography and LANDSAT multispectral scanner imagery, is discussed. It is noted that once the final land use inventory maps of irrigated agricultural lands are available and approximately scaled they may be overlaid directly onto either multispectral scanner or return beam vidicon prints, thereby providing an inexpensive updating procedure.

  7. Semiconductor Laser Multi-Spectral Sensing and Imaging

    Directory of Open Access Journals (Sweden)

    Han Q. Le

    2010-01-01

    Full Text Available Multi-spectral laser imaging is a technique that can offer a combination of the laser capability of accurate spectral sensing with the desirable features of passive multispectral imaging. The technique can be used for detection, discrimination, and identification of objects by their spectral signature. This article describes and reviews the development and evaluation of semiconductor multi-spectral laser imaging systems. Although the method is certainly not specific to any laser technology, the use of semiconductor lasers is significant with respect to practicality and affordability. More relevantly, semiconductor lasers have their own characteristics; they offer excellent wavelength diversity but usually with modest power. Thus, system design and engineering issues are analyzed for approaches and trade-offs that can make the best use of semiconductor laser capabilities in multispectral imaging. A few systems were developed and the technique was tested and evaluated on a variety of natural and man-made objects. It was shown capable of high spectral resolution imaging which, unlike non-imaging point sensing, allows detecting and discriminating objects of interest even without a priori spectroscopic knowledge of the targets. Examples include material and chemical discrimination. It was also shown capable of dealing with the complexity of interpreting diffuse scattered spectral images and produced results that could otherwise be ambiguous with conventional imaging. Examples with glucose and spectral imaging of drug pills were discussed. Lastly, the technique was shown with conventional laser spectroscopy such as wavelength modulation spectroscopy to image a gas (CO. These results suggest the versatility and power of multi-spectral laser imaging, which can be practical with the use of semiconductor lasers.

  8. Semiconductor laser multi-spectral sensing and imaging.

    Science.gov (United States)

    Le, Han Q; Wang, Yang

    2010-01-01

    Multi-spectral laser imaging is a technique that can offer a combination of the laser capability of accurate spectral sensing with the desirable features of passive multispectral imaging. The technique can be used for detection, discrimination, and identification of objects by their spectral signature. This article describes and reviews the development and evaluation of semiconductor multi-spectral laser imaging systems. Although the method is certainly not specific to any laser technology, the use of semiconductor lasers is significant with respect to practicality and affordability. More relevantly, semiconductor lasers have their own characteristics; they offer excellent wavelength diversity but usually with modest power. Thus, system design and engineering issues are analyzed for approaches and trade-offs that can make the best use of semiconductor laser capabilities in multispectral imaging. A few systems were developed and the technique was tested and evaluated on a variety of natural and man-made objects. It was shown capable of high spectral resolution imaging which, unlike non-imaging point sensing, allows detecting and discriminating objects of interest even without a priori spectroscopic knowledge of the targets. Examples include material and chemical discrimination. It was also shown capable of dealing with the complexity of interpreting diffuse scattered spectral images and produced results that could otherwise be ambiguous with conventional imaging. Examples with glucose and spectral imaging of drug pills were discussed. Lastly, the technique was shown with conventional laser spectroscopy such as wavelength modulation spectroscopy to image a gas (CO). These results suggest the versatility and power of multi-spectral laser imaging, which can be practical with the use of semiconductor lasers.

  9. BEE FORAGE MAPPING BASED ON MULTISPECTRAL IMAGES LANDSAT

    Directory of Open Access Journals (Sweden)

    A. Moskalenko

    2016-10-01

    Full Text Available Possibilities of bee forage identification and mapping based on multispectral images have been shown in the research. Spectral brightness of bee forage has been determined with the use of satellite images. The effectiveness of some methods of image classification for mapping of bee forage is shown. Keywords: bee forage, mapping, multispectral images, image classification.

  10. Comparison of sea-ice freeboard and thickness distributions from aircraft data and cryosat-2

    DEFF Research Database (Denmark)

    accurate range measurements. During the CryoSat Validation Experiment (CryoVEx) 2011 in the Lincoln Sea, Cryosat-2 underpasses were accomplished with two aircraft, which carried an airborne laser-scanner, a radar altimeter and an electromagnetic induction device for direct sea-ice thickness retrieval. Both...... aircraft flew in close formation at the same time of a CryoSat-2 overpass. This is a study about the comparison of the sea-ice freeboard and thickness distribution of airborne validation and CryoSat-2 measurements within the multi-year sea-ice region of the Lincoln Sea in spring, with respect...

  11. Neurosurgical operating computerized tomographic scanner system. The CT scanner in the operating theater

    Energy Technology Data Exchange (ETDEWEB)

    Okudera, Hiroshi; Sugita, Kenichiro; Kobayashi, Shigeaki; Kimishima, Sakae; Yoshida, Hisashi

    1988-12-01

    A neurosurgical operating computerized tomography scanner system is presented. This system has been developed for obtaining intra- and postoperative CT images in the operating room. A TCT-300 scanner (manufactured by the Toshiba Co., Tokyo) is placed in the operating room. The realization of a true intraoperative CT image requires certain improvements in the CT scanner and operating table. To adjust the axis of the co-ordinates of the motor system of the MST-7000 microsurgical operating table (manufactured by the Mizuho Ika Co., Tokyo) to the CT scanner, we have designed an interface and a precise motor system so that the computer of the CT scanner can directly control the movement of the operating table. Furthermore, a new head-fixation system has been designed for producing artifact-free intraoperative CT images. The head-pins of the head-fixation system are made of carbon-fiber bars and titanium tips. A simulation study of the total system in the operating room with the CT scanner, operating table, and head holder using a skull model yielded a degree of error similar to that in the phantom testing of the original scanner. Three patients underwent resection of a glial tumor using this system. Intraoperative CT scans taken after dural opening showed a bulging of the cortex, a shift in the central structure, and a displacement of the cortical subarachnoid spaces under the influence of gravity. With a contrast medium the edge of the surrounding brain after resection was enhanced and the residual tumor mass was demonstrated clearly. This system makes it possible to obtain a noninvasive intraoperative image in a situation where structural shifts are taking place.

  12. Lattice algebra approach to multispectral analysis of ancient documents.

    Science.gov (United States)

    Valdiviezo-N, Juan C; Urcid, Gonzalo

    2013-02-01

    This paper introduces a lattice algebra procedure that can be used for the multispectral analysis of historical documents and artworks. Assuming the presence of linearly mixed spectral pixels captured in a multispectral scene, the proposed method computes the scaled min- and max-lattice associative memories to determine the purest pixels that best represent the spectra of single pigments. The estimation of fractional proportions of pure spectra at each image pixel is used to build pigment abundance maps that can be used for subsequent restoration of damaged parts. Application examples include multispectral images acquired from the Archimedes Palimpsest and a Mexican pre-Hispanic codex.

  13. Novel instrumentation of multispectral imaging technology for detecting tissue abnormity

    Science.gov (United States)

    Yi, Dingrong; Kong, Linghua

    2012-10-01

    Multispectral imaging is becoming a powerful tool in a wide range of biological and clinical studies by adding spectral, spatial and temporal dimensions to visualize tissue abnormity and the underlying biological processes. A conventional spectral imaging system includes two physically separated major components: a band-passing selection device (such as liquid crystal tunable filter and diffraction grating) and a scientific-grade monochromatic camera, and is expensive and bulky. Recently micro-arrayed narrow-band optical mosaic filter was invented and successfully fabricated to reduce the size and cost of multispectral imaging devices in order to meet the clinical requirement for medical diagnostic imaging applications. However the challenging issue of how to integrate and place the micro filter mosaic chip to the targeting focal plane, i.e., the imaging sensor, of an off-shelf CMOS/CCD camera is not reported anywhere. This paper presents the methods and results of integrating such a miniaturized filter with off-shelf CMOS imaging sensors to produce handheld real-time multispectral imaging devices for the application of early stage pressure ulcer (ESPU) detection. Unlike conventional multispectral imaging devices which are bulky and expensive, the resulting handheld real-time multispectral ESPU detector can produce multiple images at different center wavelengths with a single shot, therefore eliminates the image registration procedure required by traditional multispectral imaging technologies.

  14. Remote sensing of acid sulfate soils using multispectral and gamma-ray data

    International Nuclear Information System (INIS)

    Bierwirth, P.N.; Graham, T.L.

    1998-01-01

    Acid sulfate soils are a significant environmental problem in coastal regions of Australia. Drainage and disturbance of coastal lands can result in acid soil degradation and the release of sulfuric acid and toxic metals into coastal waters. Remote sensing can provide a useful tool for detection of these soils and monitoring of their disturbance. As acid sulfate soils become oxidised with exposure to air, iron-minerals are produced and precipitate at the surface. This results from the breakdown of pyrite to form hydrated iron minerals and elemental sulfur, the oxidation of which produces acidity. The concentration of iron minerals at the surface can be an indicator of the level of acid sulfate soil activity in the near subsurface. These iron minerals include goethite, ferrihydrite and jarosite. Space-borne remote sensing scanners such as Landsat TM are capable of detecting iron minerals as a result of ferric ion absorption of solar radiation. Hyperspectral scanners are capable of further discrimination of individual minerals. This paper will discuss spectral characteristics of active acid sulfate soils and demonstrate the use of spectral unmixing algorithms on Landsat TM to detect problem areas at the surface. This method matches multispectral data to material reflectance-spectra known as end-members. These end-members or materials are then resolved mathematically as to their respective contributions to the overall reflectance (Bierwirth, 1990). In this way, abundances for particular materials can be derived.Digital elevation data was used to distinguish between the iron minerals due to weathering of bedrock in upland areas and acid sulfate soils on the plains. Also, the results of a high resolution (200m linespacing) airborne gamma-ray survey are presented. This data senses the concentration of radioelements down to about 40 cm depth and is largely unaffected by vegetation. Concentrations of gamma-emitting elements can indicate the type and depth of alluvium that

  15. Long-Range WindScanner System

    DEFF Research Database (Denmark)

    Vasiljevic, Nikola; Lea, Guillaume; Courtney, Michael

    2016-01-01

    The technical aspects of a multi-Doppler LiDAR instrument, the long-range WindScanner system, are presented accompanied by an overview of the results from several field campaigns. The long-range WindScanner system consists of three spatially-separated, scanning coherent Doppler LiDARs and a remote......-rangeWindScanner system measures the wind field by emitting and directing three laser beams to intersect, and then scanning the beam intersection over a region of interest. The long-range WindScanner system was developed to tackle the need for high-quality observations of wind fields on scales of modern wind turbine...

  16. Utilization of Multispectral Images for Meat Color Measurements

    DEFF Research Database (Denmark)

    Trinderup, Camilla Himmelstrup; Dahl, Anders Lindbjerg; Carstensen, Jens Michael

    2013-01-01

    This short paper describes how the use of multispectral imaging for color measurement can be utilized in an efficient and descriptive way for meat scientists. The basis of the study is meat color measurements performed with a multispectral imaging system as well as with a standard colorimeter...... of color and color variance than what is obtained by the standard colorimeter....

  17. The cobalt-60 container scanner

    International Nuclear Information System (INIS)

    Jigang, A.; Liye, Z.; Yisi, L.; Haifeng, W.; Zhifang, W.; Liqiang, W.; Yuanshi, Z.; Xincheng, X.; Furong, L.; Baozeng, G.; Chunfa, S.

    1997-01-01

    The Institute of Nuclear Energy Technology (INET) has successfully designed and constructed a container (cargo) scanner, which uses cobalt-60 of 100-300 Ci as radiation source. The following performances of the Cobalt-60 container scanner have been achieved at INET: a) IQI (Image Quality Indicator) - 2.5% behind 100 mm of steel; b) CI (Contrast Indicator) - 0.7% behind 100 mm of steel; c) SP (Steel Penetration) - 240 mm of steel; d) Maximum Dose per Scanning - 0.02mGy; e) Throughput - twenty 40-foot containers per hour. These performances are equal or similar to those of the accelerator scanners. Besides these nice enough inspection properties, the Cobalt-60 scanner possesses many other special features which are better than accelerator scanners: a) cheap price - it will be only or two tenths of the accelerator scanner's; b) low radiation intensity - the radiation protection problem is much easier to solve and a lot of money can be saved on the radiation shielding building; c) much smaller area for installation and operation; d) simple operation and convenient maintenance; e) high reliability and stability. The Cobalt-60 container (or cargo) scanner is satisfied for boundary customs, seaports, airports and railway stations etc. Because of the nice special features said above, it is more suitable to be applied widely. Its high properties and low price will make it have much better application prospects

  18. Multispectral Imaging of Wok-Fried Vegetables

    DEFF Research Database (Denmark)

    Clemmensen, Line Katrine Harder; Dissing, Bjørn Skovlund; Hyldig, Grethe

    2012-01-01

    Quality control in the food industry is often performed by measuring various chemical compounds in the food involved. The authors propose an imaging concept for acquiring high-quality multispectral images to evaluate optical reflection changes in carrots and celeriac over a period of 14 days....... For comparison, sensory analysis was performed on the same samples. Prior to multispectral image recording, the vegetables were prefried and frozen at -30 °C for 4 months. During the 14 days of image recording, the vegetables were kept at +5 °C. In this period, surface changes and thereby reflectance properties...

  19. Scanner calibration revisited

    Directory of Open Access Journals (Sweden)

    Pozhitkov Alexander E

    2010-07-01

    Full Text Available Abstract Background Calibration of a microarray scanner is critical for accurate interpretation of microarray results. Shi et al. (BMC Bioinformatics, 2005, 6, Art. No. S11 Suppl. 2. reported usage of a Full Moon BioSystems slide for calibration. Inspired by the Shi et al. work, we have calibrated microarray scanners in our previous research. We were puzzled however, that most of the signal intensities from a biological sample fell below the sensitivity threshold level determined by the calibration slide. This conundrum led us to re-investigate the quality of calibration provided by the Full Moon BioSystems slide as well as the accuracy of the analysis performed by Shi et al. Methods Signal intensities were recorded on three different microarray scanners at various photomultiplier gain levels using the same calibration slide from Full Moon BioSystems. Data analysis was conducted on raw signal intensities without normalization or transformation of any kind. Weighted least-squares method was used to fit the data. Results We found that initial analysis performed by Shi et al. did not take into account autofluorescence of the Full Moon BioSystems slide, which led to a grossly distorted microarray scanner response. Our analysis revealed that a power-law function, which is explicitly accounting for the slide autofluorescence, perfectly described a relationship between signal intensities and fluorophore quantities. Conclusions Microarray scanners respond in a much less distorted fashion than was reported by Shi et al. Full Moon BioSystems calibration slides are inadequate for performing calibration. We recommend against using these slides.

  20. Multispectral biometrics systems and applications

    CERN Document Server

    Zhang, David; Gong, Yazhuo

    2016-01-01

    Describing several new biometric technologies, such as high-resolution fingerprint, finger-knuckle-print, multi-spectral backhand, 3D fingerprint, tongueprint, 3D ear, and multi-spectral iris recognition technologies, this book analyzes a number of efficient feature extraction, matching and fusion algorithms and how potential systems have been developed. Focusing on how to develop new biometric technologies based on the requirements of applications, and how to design efficient algorithms to deliver better performance, the work is based on the author’s research with experimental results under different challenging conditions described in the text. The book offers a valuable resource for researchers, professionals and postgraduate students working in the fields of computer vision, pattern recognition, biometrics, and security applications, amongst others.

  1. Low SWaP multispectral sensors using dichroic filter arrays

    Science.gov (United States)

    Dougherty, John; Varghese, Ron

    2015-06-01

    The benefits of multispectral imaging are well established in a variety of applications including remote sensing, authentication, satellite and aerial surveillance, machine vision, biomedical, and other scientific and industrial uses. However, many of the potential solutions require more compact, robust, and cost-effective cameras to realize these benefits. The next generation of multispectral sensors and cameras needs to deliver improvements in size, weight, power, portability, and spectral band customization to support widespread deployment for a variety of purpose-built aerial, unmanned, and scientific applications. A novel implementation uses micro-patterning of dichroic filters1 into Bayer and custom mosaics, enabling true real-time multispectral imaging with simultaneous multi-band image acquisition. Consistent with color image processing, individual spectral channels are de-mosaiced with each channel providing an image of the field of view. This approach can be implemented across a variety of wavelength ranges and on a variety of detector types including linear, area, silicon, and InGaAs. This dichroic filter array approach can also reduce payloads and increase range for unmanned systems, with the capability to support both handheld and autonomous systems. Recent examples and results of 4 band RGB + NIR dichroic filter arrays in multispectral cameras are discussed. Benefits and tradeoffs of multispectral sensors using dichroic filter arrays are compared with alternative approaches - including their passivity, spectral range, customization options, and scalable production.

  2. Twisting wire scanner

    International Nuclear Information System (INIS)

    Gharibyan, V.; Delfs, A.; Koruptchenkov, I.; Noelle, D.; Tiessen, H.; Werner, M.; Wittenburg, K.

    2012-11-01

    A new type of 'two-in-one' wire scanner is proposed. Recent advances in linear motors' technology make it possible to combine translational and rotational movements. This will allow to scan the beam in two perpendicular directions using a single driving motor and a special fork attached to it. Vertical or horizontal mounting will help to escape problems associated with the 45 deg scanners. Test results of the translational part with linear motors is presented.

  3. A Novel Perceptual Hash Algorithm for Multispectral Image Authentication

    Directory of Open Access Journals (Sweden)

    Kaimeng Ding

    2018-01-01

    Full Text Available The perceptual hash algorithm is a technique to authenticate the integrity of images. While a few scholars have worked on mono-spectral image perceptual hashing, there is limited research on multispectral image perceptual hashing. In this paper, we propose a perceptual hash algorithm for the content authentication of a multispectral remote sensing image based on the synthetic characteristics of each band: firstly, the multispectral remote sensing image is preprocessed with band clustering and grid partition; secondly, the edge feature of the band subsets is extracted by band fusion-based edge feature extraction; thirdly, the perceptual feature of the same region of the band subsets is compressed and normalized to generate the perceptual hash value. The authentication procedure is achieved via the normalized Hamming distance between the perceptual hash value of the recomputed perceptual hash value and the original hash value. The experiments indicated that our proposed algorithm is robust compared to content-preserved operations and it efficiently authenticates the integrity of multispectral remote sensing images.

  4. Recent micro-CT scanner developments at UGCT

    Energy Technology Data Exchange (ETDEWEB)

    Dierick, Manuel, E-mail: Manuel.Dierick@UGent.be [UGCT-Department of Physics and Astronomy, Faculty of Sciences, Ghent University, Proeftuinstraat 86, 9000 Ghent (Belgium); XRE, X-Ray Engineering bvba, De Pintelaan 111, 9000 Ghent (Belgium); Van Loo, Denis, E-mail: info@XRE.be [XRE, X-Ray Engineering bvba, De Pintelaan 111, 9000 Ghent (Belgium); Masschaele, Bert [UGCT-Department of Physics and Astronomy, Faculty of Sciences, Ghent University, Proeftuinstraat 86, 9000 Ghent (Belgium); XRE, X-Ray Engineering bvba, De Pintelaan 111, 9000 Ghent (Belgium); Van den Bulcke, Jan [UGCT-Woodlab-UGent, Department of Forest and Water Management, Faculty of Bioscience Engineering, Ghent University, Coupure Links 653, 9000 Ghent (Belgium); Van Acker, Joris, E-mail: Joris.VanAcker@UGent.be [UGCT-Woodlab-UGent, Department of Forest and Water Management, Faculty of Bioscience Engineering, Ghent University, Coupure Links 653, 9000 Ghent (Belgium); Cnudde, Veerle, E-mail: Veerle.Cnudde@UGent.be [UGCT-SGIG, Department of Geology and Soil Science, Faculty of Sciences, Ghent University, Krijgslaan 281, S8, 9000 Ghent (Belgium); Van Hoorebeke, Luc, E-mail: Luc.VanHoorebeke@UGent.be [UGCT-Department of Physics and Astronomy, Faculty of Sciences, Ghent University, Proeftuinstraat 86, 9000 Ghent (Belgium)

    2014-04-01

    This paper describes two X-ray micro-CT scanners which were recently developed to extend the experimental possibilities of microtomography research at the Centre for X-ray Tomography ( (www.ugct.ugent.be)) of the Ghent University (Belgium). The first scanner, called Nanowood, is a wide-range CT scanner with two X-ray sources (160 kV{sub max}) and two detectors, resolving features down to 0.4 μm in small samples, but allowing samples up to 35 cm to be scanned. This is a sample size range of 3 orders of magnitude, making this scanner well suited for imaging multi-scale materials such as wood, stone, etc. Besides the traditional cone-beam acquisition, Nanowood supports helical acquisition, and it can generate images with significant phase-contrast contributions. The second scanner, known as the Environmental micro-CT scanner (EMCT), is a gantry based micro-CT scanner with variable magnification for scanning objects which are not easy to rotate in a standard micro-CT scanner, for example because they are physically connected to external experimental hardware such as sensor wiring, tubing or others. This scanner resolves 5 μm features, covers a field-of-view of about 12 cm wide with an 80 cm vertical travel range. Both scanners will be extensively described and characterized, and their potential will be demonstrated with some key application results.

  5. Recent micro-CT scanner developments at UGCT

    International Nuclear Information System (INIS)

    Dierick, Manuel; Van Loo, Denis; Masschaele, Bert; Van den Bulcke, Jan; Van Acker, Joris; Cnudde, Veerle; Van Hoorebeke, Luc

    2014-01-01

    This paper describes two X-ray micro-CT scanners which were recently developed to extend the experimental possibilities of microtomography research at the Centre for X-ray Tomography ( (www.ugct.ugent.be)) of the Ghent University (Belgium). The first scanner, called Nanowood, is a wide-range CT scanner with two X-ray sources (160 kV max ) and two detectors, resolving features down to 0.4 μm in small samples, but allowing samples up to 35 cm to be scanned. This is a sample size range of 3 orders of magnitude, making this scanner well suited for imaging multi-scale materials such as wood, stone, etc. Besides the traditional cone-beam acquisition, Nanowood supports helical acquisition, and it can generate images with significant phase-contrast contributions. The second scanner, known as the Environmental micro-CT scanner (EMCT), is a gantry based micro-CT scanner with variable magnification for scanning objects which are not easy to rotate in a standard micro-CT scanner, for example because they are physically connected to external experimental hardware such as sensor wiring, tubing or others. This scanner resolves 5 μm features, covers a field-of-view of about 12 cm wide with an 80 cm vertical travel range. Both scanners will be extensively described and characterized, and their potential will be demonstrated with some key application results

  6. Multi-spectral confocal microendoscope for in-vivo imaging

    Science.gov (United States)

    Rouse, Andrew Robert

    The concept of in-vivo multi-spectral confocal microscopy is introduced. A slit-scanning multi-spectral confocal microendoscope (MCME) was built to demonstrate the technique. The MCME employs a flexible fiber-optic catheter coupled to a custom built slit-scan confocal microscope fitted with a custom built imaging spectrometer. The catheter consists of a fiber-optic imaging bundle linked to a miniature objective and focus assembly. The design and performance of the miniature objective and focus assembly are discussed. The 3mm diameter catheter may be used on its own or routed though the instrument channel of a commercial endoscope. The confocal nature of the system provides optical sectioning with 3mum lateral resolution and 30mum axial resolution. The prism based multi-spectral detection assembly is typically configured to collect 30 spectral samples over the visible chromatic range. The spectral sampling rate varies from 4nm/pixel at 490nm to 8nm/pixel at 660nm and the minimum resolvable wavelength difference varies from 7nm to 18nm over the same spectral range. Each of these characteristics are primarily dictated by the dispersive power of the prism. The MCME is designed to examine cellular structures during optical biopsy and to exploit the diagnostic information contained within the spectral domain. The primary applications for the system include diagnosis of disease in the gastro-intestinal tract and female reproductive system. Recent data from the grayscale imaging mode are presented. Preliminary multi-spectral results from phantoms, cell cultures, and excised human tissue are presented to demonstrate the potential of in-vivo multi-spectral imaging.

  7. MULTI-TEMPORAL ASSESSMENT OF LYCHEE TREE CROP STRUCTURE USING MULTI-SPECTRAL RPAS IMAGERY

    Directory of Open Access Journals (Sweden)

    K. Johansen

    2017-08-01

    Full Text Available The lychee tree is native to China and produce small fleshy fruit up to 5 cm in diameter. Lychee production in Australia is worth > $20 million annually. Pruning of trees encourages new growth, has a positive effect on fruiting of lychee, makes fruit-picking easier, and may increase yield, as it increases light interception and tree crown surface area. The objective of this research was to assess changes in tree structure, i.e. tree crown circumference, width, height and Plant Projective Cover (PPC using multi-spectral Remotely Piloted Aircraft System (RPAS imagery collected before and after pruning of a lychee plantation. A secondary objective was to assess any variations in the results as a function of various flying heights (30, 50 and 70 m. Pre- and post-pruning results showed significant differences in all measured tree structural parameters, including an average decrease in: tree crown circumference of 1.94 m; tree crown width of 0.57 m; tree crown height of 0.62 m; and PPC of 14.8 %. The different flying heights produced similar measurements of tree crown width and PPC, whereas tree crown circumference and height measurements decreased with increasing flying height. These results show that multi-spectral RPAS imagery can provide a suitable means of assessing pruning efforts undertaken by contractors based on changes in tree structure of lychee plantations and that it is important to collect imagery in a consistent manner, as varying flying heights may cause changes to tree structural measurements.

  8. Twisting wire scanner

    Energy Technology Data Exchange (ETDEWEB)

    Gharibyan, V.; Delfs, A.; Koruptchenkov, I.; Noelle, D.; Tiessen, H.; Werner, M.; Wittenburg, K.

    2012-11-15

    A new type of 'two-in-one' wire scanner is proposed. Recent advances in linear motors' technology make it possible to combine translational and rotational movements. This will allow to scan the beam in two perpendicular directions using a single driving motor and a special fork attached to it. Vertical or horizontal mounting will help to escape problems associated with the 45 deg scanners. Test results of the translational part with linear motors is presented.

  9. Inverse analysis of non-uniform temperature distributions using multispectral pyrometry

    Science.gov (United States)

    Fu, Tairan; Duan, Minghao; Tian, Jibin; Shi, Congling

    2016-05-01

    Optical diagnostics can be used to obtain sub-pixel temperature information in remote sensing. A multispectral pyrometry method was developed using multiple spectral radiation intensities to deduce the temperature area distribution in the measurement region. The method transforms a spot multispectral pyrometer with a fixed field of view into a pyrometer with enhanced spatial resolution that can give sub-pixel temperature information from a "one pixel" measurement region. A temperature area fraction function was defined to represent the spatial temperature distribution in the measurement region. The method is illustrated by simulations of a multispectral pyrometer with a spectral range of 8.0-13.0 μm measuring a non-isothermal region with a temperature range of 500-800 K in the spot pyrometer field of view. The inverse algorithm for the sub-pixel temperature distribution (temperature area fractions) in the "one pixel" verifies this multispectral pyrometry method. The results show that an improved Levenberg-Marquardt algorithm is effective for this ill-posed inverse problem with relative errors in the temperature area fractions of (-3%, 3%) for most of the temperatures. The analysis provides a valuable reference for the use of spot multispectral pyrometers for sub-pixel temperature distributions in remote sensing measurements.

  10. Wire Scanner Motion Control Card

    CERN Document Server

    Forde, S E

    2006-01-01

    Scientists require a certain beam quality produced by the accelerator rings at CERN. The discovery potential of LHC is given by the reachable luminosity at its interaction points. The luminosity is maximized by minimizing the beam size. Therefore an accurate beam size measurement is required for optimizing the luminosity. The wire scanner performs very accurate profile measurements, but as it can not be used at full intensity in the LHC ring, it is used for calibrating other profile monitors. As the current wire scanner system, which is used in the present CERN accelerators, has not been made for the required specification of the LHC, a new design of a wire scanner motion control card is part of the LHC wire scanner project. The main functions of this card are to control the wire scanner motion and to acquire the position of the wire. In case of further upgrades at a later stage, it is required to allow an easy update of the firmware, hence the programmable features of FPGAs will be used for this purpose. The...

  11. Multispectral Panoramic Imaging System, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — International Electronic Machines Corporation, a leader in the design of precision imaging systems, will develop an innovative multispectral, panoramic imaging...

  12. Monte Carlo dose calibration in CT scanner

    International Nuclear Information System (INIS)

    Yadav, Poonam; Ramasubramanian, V.; Subbaiah, K.V.; Thayalan, K.

    2008-01-01

    Computed Tomography (CT) scanner is a high radiation imaging modality compared to radiography. The dose from a CT examination can vary greatly depending on the particular CT scanner used, the area of the body examined, and the operating parameters of the scan. CT is a major contributor to collective effective dose in diagnostic radiology. Apart from the clinical benefits, the widespread use of multislice scanner is increasing radiation level to patient in comparison with conventional CT scanner. So, it becomes necessary to increase awareness about the CT scanner. (author)

  13. Wetland Vegetation Integrity Assessment with Low Altitude Multispectral Uav Imagery

    Science.gov (United States)

    Boon, M. A.; Tesfamichael, S.

    2017-08-01

    The use of multispectral sensors on Unmanned Aerial Vehicles (UAVs) was until recently too heavy and bulky although this changed in recent times and they are now commercially available. The focus on the usage of these sensors is mostly directed towards the agricultural sector where the focus is on precision farming. Applications of these sensors for mapping of wetland ecosystems are rare. Here, we evaluate the performance of low altitude multispectral UAV imagery to determine the state of wetland vegetation in a localised spatial area. Specifically, NDVI derived from multispectral UAV imagery was used to inform the determination of the integrity of the wetland vegetation. Furthermore, we tested different software applications for the processing of the imagery. The advantages and disadvantages we experienced of these applications are also shortly presented in this paper. A JAG-M fixed-wing imaging system equipped with a MicaScene RedEdge multispectral camera were utilised for the survey. A single surveying campaign was undertaken in early autumn of a 17 ha study area at the Kameelzynkraal farm, Gauteng Province, South Africa. Structure-from-motion photogrammetry software was used to reconstruct the camera position's and terrain features to derive a high resolution orthoretified mosaic. MicaSense Atlas cloud-based data platform, Pix4D and PhotoScan were utilised for the processing. The WET-Health level one methodology was followed for the vegetation assessment, where wetland health is a measure of the deviation of a wetland's structure and function from its natural reference condition. An on-site evaluation of the vegetation integrity was first completed. Disturbance classes were then mapped using the high resolution multispectral orthoimages and NDVI. The WET-Health vegetation module completed with the aid of the multispectral UAV products indicated that the vegetation of the wetland is largely modified ("D" PES Category) and that the condition is expected to

  14. Skin condition measurement by using multispectral imaging system (Conference Presentation)

    Science.gov (United States)

    Jung, Geunho; Kim, Sungchul; Kim, Jae Gwan

    2017-02-01

    There are a number of commercially available low level light therapy (LLLT) devices in a market, and face whitening or wrinkle reduction is one of targets in LLLT. The facial improvement could be known simply by visual observation of face, but it cannot provide either quantitative data or recognize a subtle change. Clinical diagnostic instruments such as mexameter can provide a quantitative data, but it costs too high for home users. Therefore, we designed a low cost multi-spectral imaging device by adding additional LEDs (470nm, 640nm, white LED, 905nm) to a commercial USB microscope which has two LEDs (395nm, 940nm) as light sources. Among various LLLT skin treatments, we focused on getting melanin and wrinkle information. For melanin index measurements, multi-spectral images of nevus were acquired and melanin index values from color image (conventional method) and from multi-spectral images were compared. The results showed that multi-spectral analysis of melanin index can visualize nevus with a different depth and concentration. A cross section of wrinkle on skin resembles a wedge which can be a source of high frequency components when the skin image is Fourier transformed into a spatial frequency domain map. In that case, the entropy value of the spatial frequency map can represent the frequency distribution which is related with the amount and thickness of wrinkle. Entropy values from multi-spectral images can potentially separate the percentage of thin and shallow wrinkle from thick and deep wrinkle. From the results, we found that this low cost multi-spectral imaging system could be beneficial for home users of LLLT by providing the treatment efficacy in a quantitative way.

  15. NMR-CT scanner

    International Nuclear Information System (INIS)

    Kose, Katsumi; Sato, Kozo; Sugimoto, Hiroshi; Sato, Masataka.

    1983-01-01

    A brief explanation is made on the imaging methods for a practical diagnostic NMR-CT scanner : A whole-body NMR-CT scanner utilizing a resistive magnet has been developed by Toshiba in cooperation with the Institute for Solid State Physics, the University of Tokyo. Typical NMR-CT images of volunteers and patients obtained in the clinical experiments using this device are presented. Detailed specifications are also shown about the practical NMR-CTs which are to be put on the market after obtaining the government approval. (author)

  16. Statistical Quality Assessment of Pre-fried Carrots Using Multispectral Imaging

    DEFF Research Database (Denmark)

    Sharifzadeh, Sara; Clemmensen, Line Katrine Harder; Løje, Hanne

    2013-01-01

    Multispectral imaging is increasingly being used for quality assessment of food items due to its non-invasive benefits. In this paper, we investigate the use of multispectral images of pre-fried carrots, to detect changes over a period of 14 days. The idea is to distinguish changes in quality from...

  17. Light Detection and Ranging (LiDAR and Multispectral Scanner (MSS Studies Examine Coastal Environments Influenced by Mining

    Directory of Open Access Journals (Sweden)

    W. Charles Kerfoot

    2014-01-01

    Full Text Available There are numerous examples of past and present mine disposal into freshwater and marine coastal bays and riverine environments. Due to its high spatial resolution and extended water penetration, coastal light detection and ranging (LiDAR, coupled with multispectral scanning (MSS, has great promise for resolving disturbed shoreline features in low turbidity environments. Migrating mine tailings present serious issues for Lake Superior and coastal marine environments. Previous investigations in Lake Superior uncovered a metal-rich “halo” around the Keweenaw Peninsula, related to past copper mining practices. For over a century, waste rock migrating from shoreline tailing piles has moved along extensive stretches of coastline, compromising critical fish breeding grounds, damming stream outlets, transgressing into wetlands and along recreational beaches and suppressing benthic invertebrate communities. In Grand (Big Traverse Bay, Buffalo Reef is an important spawning area for lake trout and whitefish threatened by drifting tailings. The movement of tailings into Buffalo Reef cobble fields may interfere with the hatching of fish eggs and fry survival, either by filling in crevices where eggs are deposited or by toxic effects on eggs, newly hatched larvae or benthic communities. Here, we show that the coastal tailing migration is not “out of sight, out of mind”, but clearly revealed by using a combination of LiDAR and MSS techniques.

  18. New Capabilities in the Astrophysics Multispectral Archive Search Engine

    Science.gov (United States)

    Cheung, C. Y.; Kelley, S.; Roussopoulos, N.

    The Astrophysics Multispectral Archive Search Engine (AMASE) uses object-oriented database techniques to provide a uniform multi-mission and multi-spectral interface to search for data in the distributed archives. We describe our experience of porting AMASE from Illustra object-relational DBMS to the Informix Universal Data Server. New capabilities and utilities have been developed, including a spatial datablade that supports Nearest Neighbor queries.

  19. Wide field-of-view dual-band multispectral muzzle flash detection

    Science.gov (United States)

    Montoya, J.; Melchor, J.; Spiliotis, P.; Taplin, L.

    2013-06-01

    Sensor technologies are undergoing revolutionary advances, as seen in the rapid growth of multispectral methodologies. Increases in spatial, spectral, and temporal resolution, and in breadth of spectral coverage, render feasible sensors that function with unprecedented performance. A system was developed that addresses many of the key hardware requirements for a practical dual-band multispectral acquisition system, including wide field of view and spectral/temporal shift between dual bands. The system was designed using a novel dichroic beam splitter and dual band-pass filter configuration that creates two side-by-side images of a scene on a single sensor. A high-speed CMOS sensor was used to simultaneously capture data from the entire scene in both spectral bands using a short focal-length lens that provided a wide field-of-view. The beam-splitter components were arranged such that the two images were maintained in optical alignment and real-time intra-band processing could be carried out using only simple arithmetic on the image halves. An experiment related to limitations of the system to address multispectral detection requirements was performed. This characterized the system's low spectral variation across its wide field of view. This paper provides lessons learned on the general limitation of key hardware components required for multispectral muzzle flash detection, using the system as a hardware example combined with simulated multispectral muzzle flash and background signatures.

  20. Estimating Aircraft Heading Based on Laserscanner Derived Point Clouds

    Science.gov (United States)

    Koppanyi, Z.; Toth, C., K.

    2015-03-01

    Using LiDAR sensors for tracking and monitoring an operating aircraft is a new application. In this paper, we present data processing methods to estimate the heading of a taxiing aircraft using laser point clouds. During the data acquisition, a Velodyne HDL-32E laser scanner tracked a moving Cessna 172 airplane. The point clouds captured at different times were used for heading estimation. After addressing the problem and specifying the equation of motion to reconstruct the aircraft point cloud from the consecutive scans, three methods are investigated here. The first requires a reference model to estimate the relative angle from the captured data by fitting different cross-sections (horizontal profiles). In the second approach, iterative closest point (ICP) method is used between the consecutive point clouds to determine the horizontal translation of the captured aircraft body. Regarding the ICP, three different versions were compared, namely, the ordinary 3D, 3-DoF 3D and 2-DoF 3D ICP. It was found that 2-DoF 3D ICP provides the best performance. Finally, the last algorithm searches for the unknown heading and velocity parameters by minimizing the volume of the reconstructed plane. The three methods were compared using three test datatypes which are distinguished by object-sensor distance, heading and velocity. We found that the ICP algorithm fails at long distances and when the aircraft motion direction perpendicular to the scan plane, but the first and the third methods give robust and accurate results at 40m object distance and at ~12 knots for a small Cessna airplane.

  1. Monitoring temporal microstructural variations of skeletal muscle tissues by multispectral Mueller matrix polarimetry

    Science.gov (United States)

    Dong, Yang; He, Honghui; He, Chao; Ma, Hui

    2017-02-01

    Mueller matrix polarimetry is a powerful tool for detecting microscopic structures, therefore can be used to monitor physiological changes of tissue samples. Meanwhile, spectral features of scattered light can also provide abundant microstructural information of tissues. In this paper, we take the 2D multispectral backscattering Mueller matrix images of bovine skeletal muscle tissues, and analyze their temporal variation behavior using multispectral Mueller matrix parameters. The 2D images of the Mueller matrix elements are reduced to the multispectral frequency distribution histograms (mFDHs) to reveal the dominant structural features of the muscle samples more clearly. For quantitative analysis, the multispectral Mueller matrix transformation (MMT) parameters are calculated to characterize the microstructural variations during the rigor mortis and proteolysis processes of the skeletal muscle tissue samples. The experimental results indicate that the multispectral MMT parameters can be used to judge different physiological stages for bovine skeletal muscle tissues in 24 hours, and combining with the multispectral technique, the Mueller matrix polarimetry and FDH analysis can monitor the microstructural variation features of skeletal muscle samples. The techniques may be used for quick assessment and quantitative monitoring of meat qualities in food industry.

  2. Multispectral Video-Microscope Modified for Skin Diagnostics

    Directory of Open Access Journals (Sweden)

    Rubins U.

    2014-12-01

    Full Text Available Commercial DinoLite AD413 digital microscope was modified for skin diagnostics purposes. The original LED ring (4 white and 4 ultraviolet light emitters of microscope was replaced by a custom-designed 16-LED ring module consisting of four LED groups (450, 545, 660 and 940 nm, and an onboard LED controller with USB hub was added. The video acquisition and LED switching are performed using custom-designed Matlab software which provides real-time spectral analysis of multi-spectral images and calculation of skin chromophore optical density. The developed multispectral video-microscope is mainly meant for diagnostics of skin malformations, e.g. skin cancerous lesions.

  3. Color and textural quality of packaged wild rocket measured by multispectral imaging

    DEFF Research Database (Denmark)

    Løkke, Mette Marie; Seefeldt, Helene Fast; Skov, Thomas

    2013-01-01

    Green color and texture are important attributes for the perception of freshness of wild rocket. Packaging of green leafy vegetables can postpone senescence and yellowing, but a drawback is the risk of anaerobic respiration leading to loss of tissue integrity and development of an olive-brown color....... The hypothesis underlying this paper is that color and textural quality of packaged wild rocket leaves can be predicted by multispectral imaging for faster evaluation of visual quality of leafy green vegetables in scientific experiments. Multispectral imaging was correlated to sensory evaluation of packaged wild...... rocket quality. CIELAB values derived from the multispectral images and from a spectrophotometer changed during storage, but the data were insufficient to describe variation in sensory perceived color and texture. CIELAB values from the multispectral images allowed for a more detailed determination...

  4. Overview of the aerial radiological measuring system (ARMS) program

    International Nuclear Information System (INIS)

    Deal, L.J.; Doyle, J.F. III.

    1975-01-01

    Since 1960 EG and G, Inc. has developed and maintained for the U.S. Energy Research and Development Administration (ERDA) a state-of-the-art radiation surveillance program called the Aerial Radiological Measuring System (ARMS). Radiological surveys covering more than 300,000 square miles have been performed. In addition to the radiation detector gear, the system includes an inertial navigation system, radar altimeter, meteorological probes, air sampler, air sample analyzer, multispectral cameras, aerial mapping camera and infrared scanner. The recently improved data acquisition system, REDAR, records all inputs digitally on magnetic tape and is readily mounted in fixed-wing aircraft or helicopters. The data analysis system, REDAC, is mounted in a mobile processing laboratory which accompanies the aircraft on surveys. Radiation isopleth maps, both for gross counts and selected isotopes, can be prepared in the field. Special computer software enables the ARMS to detect changes of less than 1.0 μR/hr in exposure rates between successive surveys of a given site

  5. The feasibility of a scanner-independent technique to estimate organ dose from MDCT scans: Using CTDIvol to account for differences between scanners

    International Nuclear Information System (INIS)

    Turner, Adam C.; Zankl, Maria; DeMarco, John J.; Cagnon, Chris H.; Zhang Di; Angel, Erin; Cody, Dianna D.; Stevens, Donna M.; McCollough, Cynthia H.; McNitt-Gray, Michael F.

    2010-01-01

    Purpose: Monte Carlo radiation transport techniques have made it possible to accurately estimate the radiation dose to radiosensitive organs in patient models from scans performed with modern multidetector row computed tomography (MDCT) scanners. However, there is considerable variation in organ doses across scanners, even when similar acquisition conditions are used. The purpose of this study was to investigate the feasibility of a technique to estimate organ doses that would be scanner independent. This was accomplished by assessing the ability of CTDI vol measurements to account for differences in MDCT scanners that lead to organ dose differences. Methods: Monte Carlo simulations of 64-slice MDCT scanners from each of the four major manufacturers were performed. An adult female patient model from the GSF family of voxelized phantoms was used in which all ICRP Publication 103 radiosensitive organs were identified. A 120 kVp, full-body helical scan with a pitch of 1 was simulated for each scanner using similar scan protocols across scanners. From each simulated scan, the radiation dose to each organ was obtained on a per mA s basis (mGy/mA s). In addition, CTDI vol values were obtained from each scanner for the selected scan parameters. Then, to demonstrate the feasibility of generating organ dose estimates from scanner-independent coefficients, the simulated organ dose values resulting from each scanner were normalized by the CTDI vol value for those acquisition conditions. Results: CTDI vol values across scanners showed considerable variation as the coefficient of variation (CoV) across scanners was 34.1%. The simulated patient scans also demonstrated considerable differences in organ dose values, which varied by up to a factor of approximately 2 between some of the scanners. The CoV across scanners for the simulated organ doses ranged from 26.7% (for the adrenals) to 37.7% (for the thyroid), with a mean CoV of 31.5% across all organs. However, when organ doses

  6. Occurrence and characteristics of mutual interference between LIDAR scanners

    Science.gov (United States)

    Kim, Gunzung; Eom, Jeongsook; Park, Seonghyeon; Park, Yongwan

    2015-05-01

    The LIDAR scanner is at the heart of object detection of the self-driving car. Mutual interference between LIDAR scanners has not been regarded as a problem because the percentage of vehicles equipped with LIDAR scanners was very rare. With the growing number of autonomous vehicle equipped with LIDAR scanner operated close to each other at the same time, the LIDAR scanner may receive laser pulses from other LIDAR scanners. In this paper, three types of experiments and their results are shown, according to the arrangement of two LIDAR scanners. We will show the probability that any LIDAR scanner will interfere mutually by considering spatial and temporal overlaps. It will present some typical mutual interference scenario and report an analysis of the interference mechanism.

  7. Spatial Quality of Manually Geocoded Multispectral and Multiresolution Mosaics

    Directory of Open Access Journals (Sweden)

    Andrija Krtalić

    2008-05-01

    Full Text Available The digital airborne multisensor and multiresolution system for collection of information (images about mine suspected area was created, within European commission project Airborne Minefield Area Reduction (ARC, EC IST-2000-25300, http://www.arc.vub.ac.be to gain a better perspective in mine suspected areas (MSP in the Republic of Croatia. The system consists of a matrix camera (visible and near infrared range of electromagnetic spectrum, 0.4-1.1 µm, thermal (thermal range of electromagnetic spectrum, 8-14 µm and a hyperspectral linear scanner. Because of a specific purpose and seeking object on the scene, the flights for collecting the images took place at heights from 130 m to 900 m above the ground. The result of a small relative flight height and large MSPs was a large number of images which cover MSPs. Therefore, the need for merging images in largest parts, for a better perspective in whole MSPs and the interaction of detected object influences on the scene appeared. The mentioned system did not dispose of the module for automatic mosaicking and geocoding, so mosaicking and after that geocoding were done manually. This process made the classification of the scene (better distinguishing of objects on the scene and fusion of multispectral and multiresolution images after that possible. Classification and image fusion can be even done by manually mosaicking and geocoding. This article demonstrated this claim.

  8. Using remotely piloted aircraft and onboard processing to optimize and expand data collection

    Science.gov (United States)

    Fladeland, M. M.; Sullivan, D. V.; Chirayath, V.; Instrella, R.; Phelps, G. A.

    2016-12-01

    Remotely piloted aircraft (RPA) have the potential to revolutionize local to regional data collection for geophysicists as platform and payload size decrease while aircraft capabilities increase. In particular, data from RPAs combine high-resolution imagery available from low flight elevations with comprehensive areal coverage, unattainable from ground investigations and difficult to acquire from manned aircraft due to budgetary and logistical costs. Low flight elevations are particularly important for detecting signals that decay exponentially with distance, such as electromagnetic fields. Onboard data processing coupled with high-bandwidth telemetry open up opportunities for real-time and near real-time data processing, producing more efficient flight plans through the use of payload-directed flight, machine learning and autonomous systems. Such applications not only strive to enhance data collection, but also enable novel sensing modalities and temporal resolution. NASA's Airborne Science Program has been refining the capabilities and applications of RPA in support of satellite calibration and data product validation for several decades. In this paper, we describe current platforms, payloads, and onboard data systems available to the research community. Case studies include Fluid Lensing for littoral zone 3D mapping, structure from motion for terrestrial 3D multispectral imaging, and airborne magnetometry on medium and small RPAs.

  9. Urban Surface Radiative Energy Budgets Determined Using Aircraft Scanner Data

    Science.gov (United States)

    Luvall, Jeffrey C.; Quattrochi, Dale A.; Rickman, Doug L.; Estes, Maury G.; Arnold, James E. (Technical Monitor)

    2002-01-01

    the surface energy budget. Knowledge of it is important in any attempt to describe the radiative and mass fluxes which occur at the surface. Use of energy terms in modeling surface energy budgets allows the direct comparison of various land surfaces encountered in a urban landscape, from vegetated (forest and herbaceous) to non-vegetated (bare soil, roads, and buildings). These terms are also easily measured using remote sensing from aircraft or satellite platforms allowing one to examine the spacial variability. The partitioning of energy budget terms depends on the surface type. In natural landscapes, the partitioning is dependent on canopy biomass, leaf area index, aerodynamic roughness, and moisture status, all of which are influenced by the development stage of the ecosystem. In urban landscapes, coverage by man-made materials substantially alters the surface face energy budget. The remotely sensed data obtained from aircraft and satellites, when properly calibrated allows the measurement of important terms in the radiative surface energy budget a urban landscape scale.

  10. Utility of multispectral imaging for nuclear classification of routine clinical histopathology imagery

    Directory of Open Access Journals (Sweden)

    Harvey Neal R

    2007-07-01

    Full Text Available Abstract Background We present an analysis of the utility of multispectral versus standard RGB imagery for routine H&E stained histopathology images, in particular for pixel-level classification of nuclei. Our multispectral imagery has 29 spectral bands, spaced 10 nm within the visual range of 420–700 nm. It has been hypothesized that the additional spectral bands contain further information useful for classification as compared to the 3 standard bands of RGB imagery. We present analyses of our data designed to test this hypothesis. Results For classification using all available image bands, we find the best performance (equal tradeoff between detection rate and false alarm rate is obtained from either the multispectral or our "ccd" RGB imagery, with an overall increase in performance of 0.79% compared to the next best performing image type. For classification using single image bands, the single best multispectral band (in the red portion of the spectrum gave a performance increase of 0.57%, compared to performance of the single best RGB band (red. Additionally, red bands had the highest coefficients/preference in our classifiers. Principal components analysis of the multispectral imagery indicates only two significant image bands, which is not surprising given the presence of two stains. Conclusion Our results indicate that multispectral imagery for routine H&E stained histopathology provides minimal additional spectral information for a pixel-level nuclear classification task than would standard RGB imagery.

  11. Multispectral image analysis for object recognition and classification

    Science.gov (United States)

    Viau, C. R.; Payeur, P.; Cretu, A.-M.

    2016-05-01

    Computer and machine vision applications are used in numerous fields to analyze static and dynamic imagery in order to assist or automate decision-making processes. Advancements in sensor technologies now make it possible to capture and visualize imagery at various wavelengths (or bands) of the electromagnetic spectrum. Multispectral imaging has countless applications in various fields including (but not limited to) security, defense, space, medical, manufacturing and archeology. The development of advanced algorithms to process and extract salient information from the imagery is a critical component of the overall system performance. The fundamental objective of this research project was to investigate the benefits of combining imagery from the visual and thermal bands of the electromagnetic spectrum to improve the recognition rates and accuracy of commonly found objects in an office setting. A multispectral dataset (visual and thermal) was captured and features from the visual and thermal images were extracted and used to train support vector machine (SVM) classifiers. The SVM's class prediction ability was evaluated separately on the visual, thermal and multispectral testing datasets.

  12. Multispectral Image Compression Based on DSC Combined with CCSDS-IDC

    Directory of Open Access Journals (Sweden)

    Jin Li

    2014-01-01

    Full Text Available Remote sensing multispectral image compression encoder requires low complexity, high robust, and high performance because it usually works on the satellite where the resources, such as power, memory, and processing capacity, are limited. For multispectral images, the compression algorithms based on 3D transform (like 3D DWT, 3D DCT are too complex to be implemented in space mission. In this paper, we proposed a compression algorithm based on distributed source coding (DSC combined with image data compression (IDC approach recommended by CCSDS for multispectral images, which has low complexity, high robust, and high performance. First, each band is sparsely represented by DWT to obtain wavelet coefficients. Then, the wavelet coefficients are encoded by bit plane encoder (BPE. Finally, the BPE is merged to the DSC strategy of Slepian-Wolf (SW based on QC-LDPC by deep coupling way to remove the residual redundancy between the adjacent bands. A series of multispectral images is used to test our algorithm. Experimental results show that the proposed DSC combined with the CCSDS-IDC (DSC-CCSDS-based algorithm has better compression performance than the traditional compression approaches.

  13. Multispectral image compression based on DSC combined with CCSDS-IDC.

    Science.gov (United States)

    Li, Jin; Xing, Fei; Sun, Ting; You, Zheng

    2014-01-01

    Remote sensing multispectral image compression encoder requires low complexity, high robust, and high performance because it usually works on the satellite where the resources, such as power, memory, and processing capacity, are limited. For multispectral images, the compression algorithms based on 3D transform (like 3D DWT, 3D DCT) are too complex to be implemented in space mission. In this paper, we proposed a compression algorithm based on distributed source coding (DSC) combined with image data compression (IDC) approach recommended by CCSDS for multispectral images, which has low complexity, high robust, and high performance. First, each band is sparsely represented by DWT to obtain wavelet coefficients. Then, the wavelet coefficients are encoded by bit plane encoder (BPE). Finally, the BPE is merged to the DSC strategy of Slepian-Wolf (SW) based on QC-LDPC by deep coupling way to remove the residual redundancy between the adjacent bands. A series of multispectral images is used to test our algorithm. Experimental results show that the proposed DSC combined with the CCSDS-IDC (DSC-CCSDS)-based algorithm has better compression performance than the traditional compression approaches.

  14. Computer Tomography Scanners in Portugal (1990-2011

    Directory of Open Access Journals (Sweden)

    Ricardo Crispim

    2014-06-01

    Full Text Available The use of Computed Tomography (CT has increased every year since its introduction into medicine in 1972. Technological developments have made CT one of the most important imaging modalities in modern medicine. This importance is evidenced in the increasing demand and number of CT scanners installed in Portugal and worldwide. This review compiles the most recent national statistics from official publications on the number of CT scanners installed in Portugal and compares them with data available in international publications. We conclude that the number of CT scanners installed in Portugal exceeded the EU27 average by 61.5 % and the OECD average by 78.2 %, and that in 2011 there were 203 CT scanners installed in hospitals in Portugal, which equated to 19.23 CT scanners per million inhabitants.

  15. Neurosurgical operating computerized tomographic scanner system

    International Nuclear Information System (INIS)

    Okudera, Hiroshi; Sugita, Kenichiro; Kobayashi, Shigeaki; Kimishima, Sakae; Yoshida, Hisashi.

    1988-01-01

    A neurosurgical operating computerized tomography scanner system is presented. This system has been developed for obtaining intra- and postoperative CT images in the operating room. A TCT-300 scanner (manufactured by the Toshiba Co., Tokyo) is placed in the operating room. The realization of a true intraoperative CT image requires certain improvements in the CT scanner and operating table. To adjust the axis of the co-ordinates of the motor system of the MST-7000 microsurgical operating table (manufactured by the Mizuho Ika Co., Tokyo) to the CT scanner, we have designed an interface and a precise motor system so that the computer of the CT scanner can directly control the movement of the operating table. Furthermore, a new head-fixation system has been designed for producing artifact-free intraoperative CT images. The head-pins of the head-fixation system are made of carbon-fiber bars and titanium tips. A simulation study of the total system in the operating room with the CT scanner, operating table, and head holder using a skull model yielded a degree of error similar to that in the phantom testing of the original scanner. Three patients underwent resection of a glial tumor using this system. Intraoperative CT scans taken after dural opening showed a bulging of the cortex, a shift in the central structure, and a displacement of the cortical subarachnoid spaces under the influence of gravity. With a contrast medium the edge of the surrounding brain after resection was enhanced and the residual tumor mass was demonstrated clearly. This system makes it possible to obtain a noninvasive intraoperative image in a situation where structural shifts are taking place. (author)

  16. Product development of Indian cargo scanner

    International Nuclear Information System (INIS)

    2017-01-01

    A cargo scanner is required for nonintrusive screening of suspected cargo containers in trade, using high energy X-ray, to detect any mis-declarations, contraband goods concealment or hidden ammunition or explosives. The cargo scanners help authorities to process large number of suspected cargo with a high level of confidence with other additional benefit of faster clearance, minimised intrusive inspection and generating secured digital record of the process. BARC is in process of developing Indian Cargo Scanner with indigenous X-ray source. Proof of concept and conformance of the results to the international standards has been demonstrated in laboratory. Full scale equipment named as Portal scanner shall be demonstrated at Gamma field Trombay in year 2017. Subsequently the technology transfer may be done to a suitable Indian vendor

  17. Multi-spectral endogenous fluorescence imaging for bacterial differentiation

    Science.gov (United States)

    Chernomyrdin, Nikita V.; Babayants, Margarita V.; Korotkov, Oleg V.; Kudrin, Konstantin G.; Rimskaya, Elena N.; Shikunova, Irina A.; Kurlov, Vladimir N.; Cherkasova, Olga P.; Komandin, Gennady A.; Reshetov, Igor V.; Zaytsev, Kirill I.

    2017-07-01

    In this paper, the multi-spectral endogenous fluorescence imaging was implemented for bacterial differentiation. The fluorescence imaging was performed using a digital camera equipped with a set of visual bandpass filters. Narrowband 365 nm ultraviolet radiation passed through a beam homogenizer was used to excite the sample fluorescence. In order to increase a signal-to-noise ratio and suppress a non-fluorescence background in images, the intensity of the UV excitation was modulated using a mechanical chopper. The principal components were introduced for differentiating the samples of bacteria based on the multi-spectral endogenous fluorescence images.

  18. Multi-spectral band selection for satellite-based systems

    International Nuclear Information System (INIS)

    Clodius, W.B.; Weber, P.G.; Borel, C.C.; Smith, B.W.

    1998-01-01

    The design of satellite based multispectral imaging systems requires the consideration of a number of tradeoffs between cost and performance. The authors have recently been involved in the design and evaluation of a satellite based multispectral sensor operating from the visible through the long wavelength IR. The criteria that led to some of the proposed designs and the modeling used to evaluate and fine tune the designs will both be discussed. These criteria emphasized the use of bands for surface temperature retrieval and the correction of atmospheric effects. The impact of cost estimate changes on the final design will also be discussed

  19. Multispectral image pansharpening based on the contourlet transform

    Energy Technology Data Exchange (ETDEWEB)

    Amro, Israa; Mateos, Javier, E-mail: iamro@correo.ugr.e, E-mail: jmd@decsai.ugr.e [Departamento de Ciencias de la Computacion e I.A., Universidad de Granada, 18071 Granada (Spain)

    2010-02-01

    Pansharpening is a technique that fuses the information of a low resolution multispectral image (MS) and a high resolution panchromatic image (PAN), usually remote sensing images, to provide a high resolution multispectral image. In the literature, this task has been addressed from different points of view being one of the most popular the wavelets based algorithms. Recently, the contourlet transform has been proposed. This transform combines the advantages of the wavelets transform with a more efficient directional information representation. In this paper we propose a new pansharpening method based on contourlets, compare with its wavelet counterpart and assess its performance numerically and visually.

  20. ESTIMATING AIRCRAFT HEADING BASED ON LASERSCANNER DERIVED POINT CLOUDS

    Directory of Open Access Journals (Sweden)

    Z. Koppanyi

    2015-03-01

    Full Text Available Using LiDAR sensors for tracking and monitoring an operating aircraft is a new application. In this paper, we present data processing methods to estimate the heading of a taxiing aircraft using laser point clouds. During the data acquisition, a Velodyne HDL-32E laser scanner tracked a moving Cessna 172 airplane. The point clouds captured at different times were used for heading estimation. After addressing the problem and specifying the equation of motion to reconstruct the aircraft point cloud from the consecutive scans, three methods are investigated here. The first requires a reference model to estimate the relative angle from the captured data by fitting different cross-sections (horizontal profiles. In the second approach, iterative closest point (ICP method is used between the consecutive point clouds to determine the horizontal translation of the captured aircraft body. Regarding the ICP, three different versions were compared, namely, the ordinary 3D, 3-DoF 3D and 2-DoF 3D ICP. It was found that 2-DoF 3D ICP provides the best performance. Finally, the last algorithm searches for the unknown heading and velocity parameters by minimizing the volume of the reconstructed plane. The three methods were compared using three test datatypes which are distinguished by object-sensor distance, heading and velocity. We found that the ICP algorithm fails at long distances and when the aircraft motion direction perpendicular to the scan plane, but the first and the third methods give robust and accurate results at 40m object distance and at ~12 knots for a small Cessna airplane.

  1. Body scanners: are they dangerous for health?; Scanners corporels: dangereux pour la sante?

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2010-07-01

    As there is a debate about the risk of cancer and of congenital malformation associated with the use of body scanners, notably in airports, this document recalls and comments the IAEA statement on this issue. According to a study performed by this international agency, the irradiation dose is very low. But the French IRSN is more prudent and recommends not to use X ray scanner, but to look for technologies which do not use ionizing radiation

  2. Use of Multispectral Imaging in Varietal Identification of Tomato

    DEFF Research Database (Denmark)

    Shrestha, Santosh; Deleuran, Lise Christina; Olesen, Merete Halkjær

    2015-01-01

    Abstract: Multispectral imaging is an emerging non-destructive technology. In this work its potential for varietal discrimination and identification of tomato cultivars of Nepal was investigated. Two sample sets were used for the study, one with two parents and their crosses and other with eleven...... obtained provide an opportunity of using multispectral imaging technology as a primary tool in a scientific community for identification/discrimination of plant varieties in regard to genetic purity and plant variety protection/registration.......Abstract: Multispectral imaging is an emerging non-destructive technology. In this work its potential for varietal discrimination and identification of tomato cultivars of Nepal was investigated. Two sample sets were used for the study, one with two parents and their crosses and other with eleven...... cultivars to study parents and offspring relationship and varietal identification respectively. Normalized canonical discriminant analysis (nCDA) and principal component analysis (PCA) were used to analyze and compare the results for parents and offspring study. Both the results showed clear discrimination...

  3. Multispectral processing of ERTS-A (LANDSAT) data for uranium exploration in the Wind River Basin, Wyoming: a visible region ratio to enhance surface alteration associated with roll-type uraium deposits. Final report, June 1974--July 1975

    International Nuclear Information System (INIS)

    Salmon, B.C.; Pillars, W.W.

    1975-07-01

    The purpose of this report is to document possible detection capabilities of the LANDSAT multispectral scanner data for use in exploration for uranium roll-type deposits. Spectral reflectivity, mineralogy, iron content, and color paramenters were measured for twenty natural surface samples collected from a semiarid region. The relationships of these properties to LANDSAT response-weighted reflectances and to reflectance ratios are discussed. It was found that the single ratio technique of multispectral processing is likely to be sensitive enough to separate hematitic stain, but not limonitic. A combination of the LANDSAT R/sub 5,4/ and R/sub 7,6/ ratios, and a processing technique sensitive to vegetative cover is recommended for detecting areas of limonitic stain. Digital level slicing of LANDSAT R/sub 5,4/ over the Wind River Basin, after geometric correction, resulted in adequate enhancement of Triassic redbeds and lighter red materials, but not for limonitic areas. No recommendations for prospects in the area were made. Information pertaining to techniques of evaluating laboratory reflectance spectra for remote sensing applications, ratio processing, and planimetric correction of LANDSAT data is presented qualitatively

  4. Geometric Calibration and Radiometric Correction of the Maia Multispectral Camera

    Science.gov (United States)

    Nocerino, E.; Dubbini, M.; Menna, F.; Remondino, F.; Gattelli, M.; Covi, D.

    2017-10-01

    Multispectral imaging is a widely used remote sensing technique, whose applications range from agriculture to environmental monitoring, from food quality check to cultural heritage diagnostic. A variety of multispectral imaging sensors are available on the market, many of them designed to be mounted on different platform, especially small drones. This work focuses on the geometric and radiometric characterization of a brand-new, lightweight, low-cost multispectral camera, called MAIA. The MAIA camera is equipped with nine sensors, allowing for the acquisition of images in the visible and near infrared parts of the electromagnetic spectrum. Two versions are available, characterised by different set of band-pass filters, inspired by the sensors mounted on the WorlView-2 and Sentinel2 satellites, respectively. The camera details and the developed procedures for the geometric calibrations and radiometric correction are presented in the paper.

  5. Compensation strategies for PET scanners with unconventional scanner geometry

    CERN Document Server

    Gundlich, B; Oehler, M

    2006-01-01

    The small animal PET scanner ClearPET®Neuro, developed at the Forschungszentrum Julich GmbH in cooperation with the Crystal Clear Collaboration (CERN), represents scanners with an unconventional geometry: due to axial and transaxial detector gaps ClearPet®Neuro delivers inhomogeneous sinograms with missing data. When filtered backprojection (FBP) or Fourier rebinning (FORE) are applied, strong geometrical artifacts appear in the images. In this contribution we present a method that takes the geometrical sensitivity into account and converts the measured sinograms into homogeneous and complete data. By this means artifactfree images are achieved using FBP or FORE. Besides an advantageous measurement setup that reduces inhomogeneities and data gaps in the sinograms, a modification of the measured sinograms is necessary. This modification includes two steps: a geometrical normalization and corrections for missing data. To normalize the measured sinograms, computed sinograms are used that describe the geometric...

  6. Fingerprint enhancement using a multispectral sensor

    Science.gov (United States)

    Rowe, Robert K.; Nixon, Kristin A.

    2005-03-01

    The level of performance of a biometric fingerprint sensor is critically dependent on the quality of the fingerprint images. One of the most common types of optical fingerprint sensors relies on the phenomenon of total internal reflectance (TIR) to generate an image. Under ideal conditions, a TIR fingerprint sensor can produce high-contrast fingerprint images with excellent feature definition. However, images produced by the same sensor under conditions that include dry skin, dirt on the skin, and marginal contact between the finger and the sensor, are likely to be severely degraded. This paper discusses the use of multispectral sensing as a means to collect additional images with new information about the fingerprint that can significantly augment the system performance under both normal and adverse sample conditions. In the context of this paper, "multispectral sensing" is used to broadly denote a collection of images taken under different illumination conditions: different polarizations, different illumination/detection configurations, as well as different wavelength illumination. Results from three small studies using an early-stage prototype of the multispectral-TIR (MTIR) sensor are presented along with results from the corresponding TIR data. The first experiment produced data from 9 people, 4 fingers from each person and 3 measurements per finger under "normal" conditions. The second experiment provided results from a study performed to test the relative performance of TIR and MTIR images when taken under extreme dry and dirty conditions. The third experiment examined the case where the area of contact between the finger and sensor is greatly reduced.

  7. Experience with a fuel rod enrichment scanner

    International Nuclear Information System (INIS)

    Kubik, R.N.; Pettus, W.G.

    1975-01-01

    This enrichment scanner views all fuel rods produced at B and W's Commercial Nuclear Fuel Plant. The scanner design is derived from the PAPAS System reported by R. A. Forster, H. D. Menlove, and their associates at Los Alamos. The spatial resolution of the system and smoothing of the data are discussed in detail. The cost-effectiveness of multi-detector versus single detector scanners of this general design is also discussed

  8. Detecting early stage pressure ulcer on dark skin using multispectral imager

    Science.gov (United States)

    Yi, Dingrong; Kong, Linghua; Sprigle, Stephen; Wang, Fengtao; Wang, Chao; Liu, Fuhan; Adibi, Ali; Tummala, Rao

    2010-02-01

    We are developing a handheld multispectral imaging device to non-invasively inspect stage I pressure ulcers in dark pigmented skins without the need of touching the patient's skin. This paper reports some preliminary test results of using a proof-of-concept prototype. It also talks about the innovation's impact to traditional multispectral imaging technologies and the fields that will potentially benefit from it.

  9. Multi-parameter CAMAC compatible ADC scanner

    Energy Technology Data Exchange (ETDEWEB)

    Midttun, G J; Ingebretsen, F [Oslo Univ. (Norway). Fysisk Inst.; Johnsen, P J [Norsk Data A.S., Box 163, Oekern, Oslo 5, Norway

    1979-02-15

    A fast ADC scanner for multi-parameter nuclear physics experiments is described. The scanner is based on a standard CAMAC crate, and data from several different experiments can be handled simultaneously through a direct memory access (DMA) channel. The implementation on a PDP-7 computer is outlined.

  10. Scintillation scanner

    International Nuclear Information System (INIS)

    Mehrbrodt, A.W.; Mog, W.F.; Brunnett, C.J.

    1977-01-01

    A scintillation scanner having a visual image producing means coupled through a lost motion connection to the boom which supports the scintillation detector is described. The lost motion connection is adjustable to compensate for such delays as may occur between sensing and recording scintillations. 13 claims, 5 figures

  11. Radiographic scanners and shutter mechanisms in CT scanners

    International Nuclear Information System (INIS)

    Braden, A.B.; Kuwik, J.J.; Taylor, S.K.; Covic, J.

    1981-01-01

    This patent claim relates especially to the design of a shutter mechanism in a CT scanner having a rotatable source of radiation and a series of stationary radiation detectors coplanar with the path of the source and spaced about the axis of rotation of the source, and only partially encircling the path of the source. (U.K.)

  12. Imaging system models for small-bore DOI-PET scanners

    International Nuclear Information System (INIS)

    Takahashi, Hisashi; Kobayashi, Tetsuya; Yamaya, Taiga; Murayama, Hideo; Kitamura, Keishi; Hasegawa, Tomoyuki; Suga, Mikio

    2006-01-01

    Depth-of-interaction (DOI) information, which improves resolution uniformity in the field of view (FOV), is expected to lead to high-sensitivity PET scanners with small-bore detector rings. We are developing small-bore PET scanners with DOI detectors arranged in hexagonal or overlapped tetragonal patterns for small animal imaging or mammography. It is necessary to optimize the imaging system model because these scanners exhibit irregular detector sampling. In this work, we compared two imaging system models: (a) a parallel sub-LOR model in which the detector response functions (DRFs) are assumed to be uniform along the line of responses (LORs) and (b) a sub-crystal model in which each crystal is divided into a set of smaller volumes. These two models were applied to the overlapped tetragonal scanner (FOV 38.1 mm in diameter) and the hexagonal scanner (FOV 85.2 mm in diameter) simulated by GATE. We showed that the resolution non-uniformity of system model (b) was improved by 40% compared with that of system model (a) in the overlapped tetragonal scanner and that the resolution non-uniformity of system model (a) was improved by 18% compared with that of system model (b) in the hexagonal scanner. These results indicate that system model (b) should be applied to the overlapped tetragonal scanner and system model (a) should be applied to the hexagonal scanner. (author)

  13. Scanner OPC signatures: automatic vendor-to-vendor OPE matching

    Science.gov (United States)

    Renwick, Stephen P.

    2009-03-01

    As 193nm lithography continues to be stretched and the k1 factor decreases, optical proximity correction (OPC) has become a vital part of the lithographer's tool kit. Unfortunately, as is now well known, the design variations of lithographic scanners from different vendors cause them to have slightly different optical-proximity effect (OPE) behavior, meaning that they print features through pitch in distinct ways. This in turn means that their response to OPC is not the same, and that an OPC solution designed for a scanner from Company 1 may or may not work properly on a scanner from Company 2. Since OPC is not inexpensive, that causes trouble for chipmakers using more than one brand of scanner. Clearly a scanner-matching procedure is needed to meet this challenge. Previously, automatic matching has only been reported for scanners of different tool generations from the same manufacturer. In contrast, scanners from different companies have been matched using expert tuning and adjustment techniques, frequently requiring laborious test exposures. Automatic matching between scanners from Company 1 and Company 2 has remained an unsettled problem. We have recently solved this problem and introduce a novel method to perform the automatic matching. The success in meeting this challenge required three enabling factors. First, we recognized the strongest drivers of OPE mismatch and are thereby able to reduce the information needed about a tool from another supplier to that information readily available from all modern scanners. Second, we developed a means of reliably identifying the scanners' optical signatures, minimizing dependence on process parameters that can cloud the issue. Third, we carefully employed standard statistical techniques, checking for robustness of the algorithms used and maximizing efficiency. The result is an automatic software system that can predict an OPC matching solution for scanners from different suppliers without requiring expert intervention.

  14. MEMS temperature scanner: principles, advances, and applications

    Science.gov (United States)

    Otto, Thomas; Saupe, Ray; Stock, Volker; Gessner, Thomas

    2010-02-01

    Contactless measurement of temperatures has gained enormous significance in many application fields, ranging from climate protection over quality control to object recognition in public places or military objects. Thereby measurement of linear or spatially temperature distribution is often necessary. For this purposes mostly thermographic cameras or motor driven temperature scanners are used today. Both are relatively expensive and the motor drive devices are limited regarding to the scanning rate additionally. An economic alternative are temperature scanner devices based on micro mirrors. The micro mirror, attached in a simple optical setup, reflects the emitted radiation from the observed heat onto an adapted detector. A line scan of the target object is obtained by periodic deflection of the micro scanner. Planar temperature distribution will be achieved by perpendicularly moving the target object or the scanner device. Using Planck radiation law the temperature of the object is calculated. The device can be adapted to different temperature ranges and resolution by using different detectors - cooled or uncooled - and parameterized scanner parameters. With the basic configuration 40 spatially distributed measuring points can be determined with temperatures in a range from 350°C - 1000°C. The achieved miniaturization of such scanners permits the employment in complex plants with high building density or in direct proximity to the measuring point. The price advantage enables a lot of applications, especially new application in the low-price market segment This paper shows principle, setup and application of a temperature measurement system based on micro scanners working in the near infrared range. Packaging issues and measurement results will be discussed as well.

  15. Nogle muligheder i scanner data

    DEFF Research Database (Denmark)

    Juhl, Hans Jørn

    2000-01-01

    I artiklen gives en diskussion af en række af de muligheder for effektivisering af marketingaktiviteter, der er til stede for såvel mærkevareudbyder som detaillist, ved udnyttelse af information fra scanner data......I artiklen gives en diskussion af en række af de muligheder for effektivisering af marketingaktiviteter, der er til stede for såvel mærkevareudbyder som detaillist, ved udnyttelse af information fra scanner data...

  16. The number and distribution of computerised tomography scanners in Turkey

    International Nuclear Information System (INIS)

    Semin, S.; Amato, Z.

    1999-01-01

    The goal of this study was to investigate the number and distribution of CT scanners in Turkey. Our results show 173 CT scanners in Turkey in 1994, which equals 2.9 scanners per million people. All of the scanners are located in 45 cities, where 81 % of the population resides. The other 31 cities in Turkey have no scanners. Of the 173 scanners, 103 (59.6 %) are owned by the private sector and the other 70 are owned by the public sector. Of Turkey's CT scanners, 49.2 % are located in private health centres, 21.9 % in university hospitals, 16.7 % in Ministry of Health (MOH) hospitals, 10.4 % in private hospitals and 1.8 % in social security hospitals. (orig.)

  17. A Comparative Study of Land Cover Classification by Using Multispectral and Texture Data

    Directory of Open Access Journals (Sweden)

    Salman Qadri

    2016-01-01

    Full Text Available The main objective of this study is to find out the importance of machine vision approach for the classification of five types of land cover data such as bare land, desert rangeland, green pasture, fertile cultivated land, and Sutlej river land. A novel spectra-statistical framework is designed to classify the subjective land cover data types accurately. Multispectral data of these land covers were acquired by using a handheld device named multispectral radiometer in the form of five spectral bands (blue, green, red, near infrared, and shortwave infrared while texture data were acquired with a digital camera by the transformation of acquired images into 229 texture features for each image. The most discriminant 30 features of each image were obtained by integrating the three statistical features selection techniques such as Fisher, Probability of Error plus Average Correlation, and Mutual Information (F + PA + MI. Selected texture data clustering was verified by nonlinear discriminant analysis while linear discriminant analysis approach was applied for multispectral data. For classification, the texture and multispectral data were deployed to artificial neural network (ANN: n-class. By implementing a cross validation method (80-20, we received an accuracy of 91.332% for texture data and 96.40% for multispectral data, respectively.

  18. 3D whole body scanners revisited

    NARCIS (Netherlands)

    Daanen, H.A.M.; Haar, F.B. ter

    2013-01-01

    An overview of whole body scanners in 1998 (H.A.M. Daanen, G.J. Van De Water. Whole body scanners, Displays 19 (1998) 111-120) shortly after they emerged to the market revealed that the systems were bulky, slow, expensive and low in resolution. This update shows that new developments in sensing and

  19. New uses of shadow enhancement. [interpretation of geologic structures from photographic or scanner imagery of Colorado

    Science.gov (United States)

    Lee, K. (Principal Investigator); Sawatzky, D. L.

    1974-01-01

    The author has identified the following significant results. Shadow enhancement of topographic linears in photographic or scanner images is a valuable tool for interpretation of geologic structures. Whether linears will be enhanced or subdued depends on sun angle and azimuth. The relationship of the sun's attitude to topographic slopes determines which trends are available for interpretation in existing imagery, and it can be used to select the time of day, surface properties, and film and filter characteristics in planning aircraft flights or satellite orbital passes. The technique of selective shadow enhancement can be applied to all photographic or imaging experiments, but its best for snow-covered scenes, side-looking radar images, and painted relief models.

  20. Water Mapping Using Multispectral Airborne LIDAR Data

    Science.gov (United States)

    Yan, W. Y.; Shaker, A.; LaRocque, P. E.

    2018-04-01

    This study investigates the use of the world's first multispectral airborne LiDAR sensor, Optech Titan, manufactured by Teledyne Optech to serve the purpose of automatic land-water classification with a particular focus on near shore region and river environment. Although there exist recent studies utilizing airborne LiDAR data for shoreline detection and water surface mapping, the majority of them only perform experimental testing on clipped data subset or rely on data fusion with aerial/satellite image. In addition, most of the existing approaches require manual intervention or existing tidal/datum data for sample collection of training data. To tackle the drawbacks of previous approaches, we propose and develop an automatic data processing workflow for land-water classification using multispectral airborne LiDAR data. Depending on the nature of the study scene, two methods are proposed for automatic training data selection. The first method utilizes the elevation/intensity histogram fitted with Gaussian mixture model (GMM) to preliminarily split the land and water bodies. The second method mainly relies on the use of a newly developed scan line elevation intensity ratio (SLIER) to estimate the water surface data points. Regardless of the training methods being used, feature spaces can be constructed using the multispectral LiDAR intensity, elevation and other features derived from these parameters. The comprehensive workflow was tested with two datasets collected for different near shore region and river environment, where the overall accuracy yielded better than 96 %.

  1. Methods for CT automatic exposure control protocol translation between scanner platforms.

    Science.gov (United States)

    McKenney, Sarah E; Seibert, J Anthony; Lamba, Ramit; Boone, John M

    2014-03-01

    An imaging facility with a diverse fleet of CT scanners faces considerable challenges when propagating CT protocols with consistent image quality and patient dose across scanner makes and models. Although some protocol parameters can comfortably remain constant among scanners (eg, tube voltage, gantry rotation time), the automatic exposure control (AEC) parameter, which selects the overall mA level during tube current modulation, is difficult to match among scanners, especially from different CT manufacturers. Objective methods for converting tube current modulation protocols among CT scanners were developed. Three CT scanners were investigated, a GE LightSpeed 16 scanner, a GE VCT scanner, and a Siemens Definition AS+ scanner. Translation of the AEC parameters such as noise index and quality reference mAs across CT scanners was specifically investigated. A variable-diameter poly(methyl methacrylate) phantom was imaged on the 3 scanners using a range of AEC parameters for each scanner. The phantom consisted of 5 cylindrical sections with diameters of 13, 16, 20, 25, and 32 cm. The protocol translation scheme was based on matching either the volumetric CT dose index or image noise (in Hounsfield units) between two different CT scanners. A series of analytic fit functions, corresponding to different patient sizes (phantom diameters), were developed from the measured CT data. These functions relate the AEC metric of the reference scanner, the GE LightSpeed 16 in this case, to the AEC metric of a secondary scanner. When translating protocols between different models of CT scanners (from the GE LightSpeed 16 reference scanner to the GE VCT system), the translation functions were linear. However, a power-law function was necessary to convert the AEC functions of the GE LightSpeed 16 reference scanner to the Siemens Definition AS+ secondary scanner, because of differences in the AEC functionality designed by these two companies. Protocol translation on the basis of

  2. Wire scanner software and firmware issues

    International Nuclear Information System (INIS)

    Gilpatrick, John Doug

    2008-01-01

    The Los Alamos Neutron Science Center facility presently has 110 slow wire scanning profile measurement instruments located along its various beam lines. These wire scanners were developed and have been operating for at least 30 years. While the wire scanners solved many problems to operate and have served the facility well they have increasingly suffered from several problems or limitations, such as maintenance and reliability problems, antiquated components, slow data acquisition, and etc. In order to refurbish these devices, these wire scanners will be replaced with newer versions. The replacement will consist of a completely new beam line actuator, new cables, new electronics and brand new software and firmware. This note describes the functions and modes of operation that LabVIEW VI software on the real time controller and FPGA LabVIEW firmware will be required. It will be especially interesting to understand the overall architecture of these LabVIEW VIs. While this note will endeavor to describe all of the requirements and issues for the wire scanners, undoubtedly, there will be missing details that will be added as time progresses.

  3. Airborne Multi-Spectral Minefield Survey

    Science.gov (United States)

    2005-05-01

    Swedish Defence Research Agency), GEOSPACE (Austria), GTD ( Ingenieria de Sistemas y Software Industrial, Spain), IMEC (Ineruniversity MicroElectronic...RTO-MP-SET-092 18 - 1 UNCLASSIFIED/UNLIMITED UNCLASSIFIED/UNLIMITED Airborne Multi-Spectral Minefield Survey Dirk-Jan de Lange, Eric den...actions is the severe lack of baseline information. To respond to this in a rapid way, cost-efficient data acquisition methods are a key issue. de

  4. Comparison of Epson scanner quality for radiochromic film evaluation.

    Science.gov (United States)

    Alnawaf, Hani; Yu, Peter K N; Butson, Martin

    2012-09-06

    Epson Desktop scanners have been quoted as devices which match the characteristics required for the evaluation of radiation dose exposure by radiochromic films. Specifically, models such as the 10000XL have been used successfully for image analysis and are recommended by ISP for dosimetry purposes. This note investigates and compares the scanner characteristics of three Epson desktop scanner models including the Epson 10000XL, V700, and V330. Both of the latter are substantially cheaper models capable of A4 scanning. As the price variation between the V330 and the 10000XL is 20-fold (based on Australian recommended retail price), cost savings by using the cheaper scanners may be warranted based on results. By a direct comparison of scanner uniformity and reproducibility we can evaluate the accuracy of these scanners for radiochromic film dosimetry. Results have shown that all three scanners can produce adequate scanner uniformity and reproducibility, with the inexpensive V330 producing a standard deviation variation across its landscape direction of 0.7% and 1.2% in the portrait direction (reflection mode). This is compared to the V700 in reflection mode of 0.25% and 0.5% for landscape and portrait directions, respectively, and 0.5% and 0.8% for the 10000XL. In transmission mode, the V700 is comparable in reproducibility to the 10000XL for portrait and landscape mode, whilst the V330 is only capable of scanning in the landscape direction and produces a standard deviation in this direction of 1.0% compared to 0.6% (V700) and 0.25% (10000XL). Results have shown that the V700 and 10000XL are comparable scanners in quality and accuracy with the 10000XL obviously capable of imaging over an A3 area as opposed to an A4 area for the V700. The V330 scanner produced slightly lower accuracy and quality with uncertainties approximately twice as much as the other scanners. However, the results show that the V330 is still an adequate scanner and could be used for radiation

  5. Using multi-spectral sensors for vegetation mapping

    CSIR Research Space (South Africa)

    Van Deventer, Heidi

    2016-07-01

    Full Text Available Wetland and estuarine vegetation is often difficult to detect and separate from adjacent land covers with multispectral sensors for a number of reasons. The spatial resolution of space-borne sensors is often insufficient for these features which...

  6. PROCEDURES FOR ACCURATE PRODUCTION OF COLOR IMAGES FROM SATELLITE OR AIRCRAFT MULTISPECTRAL DIGITAL DATA.

    Science.gov (United States)

    Duval, Joseph S.

    1985-01-01

    Because the display and interpretation of satellite and aircraft remote-sensing data make extensive use of color film products, accurate reproduction of the color images is important. To achieve accurate color reproduction, the exposure and chemical processing of the film must be monitored and controlled. By using a combination of sensitometry, densitometry, and transfer functions that control film response curves, all of the different steps in the making of film images can be monitored and controlled. Because a sensitometer produces a calibrated exposure, the resulting step wedge can be used to monitor the chemical processing of the film. Step wedges put on film by image recording machines provide a means of monitoring the film exposure and color balance of the machines.

  7. High-speed multispectral videography with a periscope array in a spectral shaper.

    Science.gov (United States)

    Hashimoto, Kazuki; Mizuno, Hikaru; Nakagawa, Keiichi; Horisaki, Ryoichi; Iwasaki, Atsushi; Kannari, Fumihiko; Sakuma, Ichiro; Goda, Keisuke

    2014-12-15

    We present a simple method for continuous snapshot multispectral imaging or multispectral videography that achieves high-speed spectral video recording without the need for mechanical scanning and much computation for datacube construction. The enabling component of this method is an array of periscopes placed in a prism-based spectral shaper that spectrally separates the image without image deformation. As a proof-of-principle demonstration, we show five-color multispectral video recording in the visible range (200×200 pixels per spectral image frame) at a record high frame rate of at least 2800 frames per second. Our experimental results indicate that this method holds promise for various industrial and biomedical applications such as remote sensing, food inspection, and endoscopy.

  8. Multispectral code excited linear prediction coding and its application in magnetic resonance images.

    Science.gov (United States)

    Hu, J H; Wang, Y; Cahill, P T

    1997-01-01

    This paper reports a multispectral code excited linear prediction (MCELP) method for the compression of multispectral images. Different linear prediction models and adaptation schemes have been compared. The method that uses a forward adaptive autoregressive (AR) model has been proven to achieve a good compromise between performance, complexity, and robustness. This approach is referred to as the MFCELP method. Given a set of multispectral images, the linear predictive coefficients are updated over nonoverlapping three-dimensional (3-D) macroblocks. Each macroblock is further divided into several 3-D micro-blocks, and the best excitation signal for each microblock is determined through an analysis-by-synthesis procedure. The MFCELP method has been applied to multispectral magnetic resonance (MR) images. To satisfy the high quality requirement for medical images, the error between the original image set and the synthesized one is further specified using a vector quantizer. This method has been applied to images from 26 clinical MR neuro studies (20 slices/study, three spectral bands/slice, 256x256 pixels/band, 12 b/pixel). The MFCELP method provides a significant visual improvement over the discrete cosine transform (DCT) based Joint Photographers Expert Group (JPEG) method, the wavelet transform based embedded zero-tree wavelet (EZW) coding method, and the vector tree (VT) coding method, as well as the multispectral segmented autoregressive moving average (MSARMA) method we developed previously.

  9. Multispectral thermal imaging

    Energy Technology Data Exchange (ETDEWEB)

    Weber, P.G.; Bender, S.C.; Borel, C.C.; Clodius, W.B.; Smith, B.W. [Los Alamos National Lab., NM (United States). Space and Remote Sensing Sciences Group; Garrett, A.; Pendergast, M.M. [Westinghouse Savannah River Corp., Aiken, SC (United States). Savannah River Technology Center; Kay, R.R. [Sandia National Lab., Albuquerque, NM (United States). Monitoring Systems and Technology Center

    1998-12-01

    Many remote sensing applications rely on imaging spectrometry. Here the authors use imaging spectrometry for thermal and multispectral signatures measured from a satellite platform enhanced with a combination of accurate calibrations and on-board data for correcting atmospheric distortions. The approach is supported by physics-based end-to-end modeling and analysis, which permits a cost-effective balance between various hardware and software aspects. The goal is to develop and demonstrate advanced technologies and analysis tools toward meeting the needs of the customer; at the same time, the attributes of this system can address other applications in such areas as environmental change, agriculture, and volcanology.

  10. 21 CFR 882.1925 - Ultrasonic scanner calibration test block.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ultrasonic scanner calibration test block. 882... Ultrasonic scanner calibration test block. (a) Identification. An ultrasonic scanner calibration test block is a block of material with known properties used to calibrate ultrasonic scanning devices (e.g., the...

  11. Mitigating the effect of optical back-scatter in multispectral underwater imaging

    International Nuclear Information System (INIS)

    Mortazavi, Halleh; Oakley, John P; Barkat, Braham

    2013-01-01

    Multispectral imaging is a very useful technique for extracting information from the underwater world. However, optical back-scatter changes the intensity value in each spectral band and this distorts the estimated spectrum. In this work, a filter is used to detect the level of optical back-scatter in each spectral band from a set of multispectral images. Extraction of underwater object spectra can be done by subtracting the estimated level of optical back-scatter and scaling the remainder in each spectral band from the captured image in the corresponding band. An experiment has been designed to show the performance of the proposed filter for correcting the set of multispectral underwater images and recovering the pixel spectra. The multispectral images are captured by a B/W CCD digital camera with a fast tunable liquid-crystal filter in 33 narrow spectral bands in clear and different levels of turbid water. Reference estimates for the optical back-scatter spectra are found by comparing a clear and a degraded set of multispectral images. The accuracy and consistency of the proposed method, the extended Oakley–Bu cost function, is examined by comparing the estimated values with the reference level of an optical back-scatter spectrum. The same comparison is made for the simple estimation approach. The results show that the simple method is not reliable and fail to estimate the level of optical back-scatter spectrum accurately. The results from processing experimental images in turbid water show that the effect of optical back-scatter can be mitigated in the image of each spectral band and, as a result, the spectra of the object can be recovered. However, for a very high level of turbid water the recovery is limited because of the effect of extinction. (paper)

  12. PAN-SHARPENING APPROACHES BASED ON UNMIXING OF MULTISPECTRAL REMOTE SENSING IMAGERY

    Directory of Open Access Journals (Sweden)

    G. Palubinskas

    2016-06-01

    Full Text Available Model based analysis or explicit definition/listing of all models/assumptions used in the derivation of a pan-sharpening method allows us to understand the rationale or properties of existing methods and shows a way for a proper usage or proposal/selection of new methods ‘better’ satisfying the needs of a particular application. Most existing pan-sharpening methods are based mainly on the two models/assumptions: spectral consistency for high resolution multispectral data (physical relationship between multispectral and panchromatic data in a high resolution scale and spatial consistency for multispectral data (so-called Wald’s protocol first property or relationship between multispectral data in different resolution scales. Two methods, one based on a linear unmixing model and another one based on spatial unmixing, are described/proposed/modified which respect models assumed and thus can produce correct or physically justified fusion results. Earlier mentioned property ‘better’ should be measurable quantitatively, e.g. by means of so-called quality measures. The difficulty of a quality assessment task in multi-resolution image fusion or pan-sharpening is that a reference image is missing. Existing measures or so-called protocols are still not satisfactory because quite often the rationale or assumptions used are not valid or not fulfilled. From a model based view it follows naturally that a quality assessment measure can be defined as a combination of error model residuals using common or general models assumed in all fusion methods. Thus in this paper a comparison of the two earlier proposed/modified pan-sharpening methods is performed. Preliminary experiments based on visual analysis are carried out in the urban area of Munich city for optical remote sensing multispectral data and panchromatic imagery of the WorldView-2 satellite sensor.

  13. Quality assessment of butter cookies applying multispectral imaging

    Science.gov (United States)

    Andresen, Mette S; Dissing, Bjørn S; Løje, Hanne

    2013-01-01

    A method for characterization of butter cookie quality by assessing the surface browning and water content using multispectral images is presented. Based on evaluations of the browning of butter cookies, cookies were manually divided into groups. From this categorization, reference values were calculated for a statistical prediction model correlating multispectral images with a browning score. The browning score is calculated as a function of oven temperature and baking time. It is presented as a quadratic response surface. The investigated process window was the intervals 4–16 min and 160–200°C in a forced convection electrically heated oven. In addition to the browning score, a model for predicting the average water content based on the same images is presented. This shows how multispectral images of butter cookies may be used for the assessment of different quality parameters. Statistical analysis showed that the most significant wavelengths for browning predictions were in the interval 400–700 nm and the wavelengths significant for water prediction were primarily located in the near-infrared spectrum. The water prediction model was found to correctly estimate the average water content with an absolute error of 0.22%. From the images it was also possible to follow the browning and drying propagation from the cookie edge toward the center. PMID:24804036

  14. Quantitatively differentiating microstructural variations of skeletal muscle tissues by multispectral Mueller matrix imaging

    Science.gov (United States)

    Dong, Yang; He, Honghui; He, Chao; Ma, Hui

    2016-10-01

    Polarized light is sensitive to the microstructures of biological tissues and can be used to detect physiological changes. Meanwhile, spectral features of the scattered light can also provide abundant microstructural information of tissues. In this paper, we take the backscattering polarization Mueller matrix images of bovine skeletal muscle tissues during the 24-hour experimental time, and analyze their multispectral behavior using quantitative Mueller matrix parameters. In the processes of rigor mortis and proteolysis of muscle samples, multispectral frequency distribution histograms (FDHs) of the Mueller matrix elements can reveal rich qualitative structural information. In addition, we analyze the temporal variations of the sample using the multispectral Mueller matrix transformation (MMT) parameters. The experimental results indicate that the different stages of rigor mortis and proteolysis for bovine skeletal muscle samples can be judged by these MMT parameters. The results presented in this work show that combining with the multispectral technique, the FDHs and MMT parameters can characterize the microstructural variation features of skeletal muscle tissues. The techniques have the potential to be used as tools for quantitative assessment of meat qualities in food industry.

  15. Detection of Melanoma Metastases in Resected Human Lymph Nodes by Noninvasive Multispectral Photoacoustic Imaging

    Directory of Open Access Journals (Sweden)

    Gerrit Cornelis Langhout

    2014-01-01

    Full Text Available Objective. Sentinel node biopsy in patients with cutaneous melanoma improves staging, provides prognostic information, and leads to an increased survival in node-positive patients. However, frozen section analysis of the sentinel node is not reliable and definitive histopathology evaluation requires days, preventing intraoperative decision-making and immediate therapy. Photoacoustic imaging can evaluate intact lymph nodes, but specificity can be hampered by other absorbers such as hemoglobin. Near infrared multispectral photoacoustic imaging is a new approach that has the potential to selectively detect melanin. The purpose of the present study is to examine the potential of multispectral photoacoustic imaging to identify melanoma metastasis in human lymph nodes. Methods. Three metastatic and nine benign lymph nodes from eight melanoma patients were scanned ex vivo using a Vevo LAZR© multispectral photoacoustic imager and were spectrally analyzed per pixel. The results were compared to histopathology as gold standard. Results. The nodal volume could be scanned within 20 minutes. An unmixing procedure was proposed to identify melanoma metastases with multispectral photoacoustic imaging. Ultrasound overlay enabled anatomical correlation. The penetration depth of the photoacoustic signal was up to 2 cm. Conclusion. Multispectral three-dimensional photoacoustic imaging allowed for selective identification of melanoma metastases in human lymph nodes.

  16. Primer on Use of Multi-Spectral and Infra Red Imaging for On-Site Inspections

    Energy Technology Data Exchange (ETDEWEB)

    Henderson, J R

    2010-10-26

    The purpose of an On-Site Inspection (OSI) is to determine whether a nuclear explosion has occurred in violation of the Comprehensive Nuclear Test Ban Treaty (CTBT), and to gather information which might assist in identifying the violator (CTBT, Article IV, Paragraph 35) Multi-Spectral and Infra Red Imaging (MSIR) is allowed by the treaty to detect observables which might help reduce the search area and thus expedite an OSI and make it more effective. MSIR is permitted from airborne measurements, and at and below the surface to search for anomalies and artifacts (CTBT, Protocol, Part II, Paragraph 69b). The three broad types of anomalies and artifacts MSIR is expected to be capable of observing are surface disturbances (disturbed earth, plant stress or anomalous surface materials), human artifacts (man-made roads, buildings and features), and thermal anomalies. The purpose of this Primer is to provide technical information on MSIR relevant to its use for OSI. It is expected that this information may be used for general background information, to inform decisions about the selection and testing of MSIR equipment, to develop operational guidance for MSIR use during an OSI, and to support the development of a training program for OSI Inspectors. References are provided so readers can pursue a topic in more detail than the summary information provided here. The following chapters will provide more information on how MSIR can support an OSI (Section 2), a short summary what Multi-Spectral Imaging and Infra Red Imaging is (Section 3), guidance from the CTBT regarding the use of MSIR (Section 4), and a description of several nuclear explosion scenarios (Section 5) and consequent observables (Section 6). The remaining sections focus on practical aspects of using MSIR for an OSI, such as specification and selection of MSIR equipment, operational considerations for deployment of MISR equipment from an aircraft, and the conduct of field exercises to mature MSIR for an OSI

  17. Scanners for analytic print measurement: the devil in the details

    Science.gov (United States)

    Zeise, Eric K.; Williams, Don; Burns, Peter D.; Kress, William C.

    2007-01-01

    Inexpensive and easy-to-use linear and area-array scanners have frequently substituted as colorimeters and densitometers for low-frequency (i.e., large area) hard copy image measurement. Increasingly, scanners are also being used for high spatial frequency, image microstructure measurements, which were previously reserved for high performance microdensitometers. In this paper we address characteristics of flatbed reflection scanners in the evaluation of print uniformity, geometric distortion, geometric repeatability and the influence of scanner MTF and noise on analytic measurements. Suggestions are made for the specification and evaluation of scanners to be used in print image quality standards that are being developed.

  18. Free-space wavelength-multiplexed optical scanner demonstration.

    Science.gov (United States)

    Yaqoob, Zahid; Riza, Nabeel A

    2002-09-10

    Experimental demonstration of a no-moving-parts free-space wavelength-multiplexed optical scanner (W-MOS) is presented. With fast tunable lasers or optical filters and planar wavelength dispersive elements such as diffraction gratings, this microsecond-speed scanner enables large several-centimeter apertures for subdegree angular scans. The proposed W-MOS design incorporates a unique optical amplifier and variable optical attenuator combination that enables the calibration and modulation of the scanner response, leading to any desired scanned laser beam power shaping. The experimental setup uses a tunable laser centered at 1560 nm and a 600-grooves/mm blazed reflection grating to accomplish an angular scan of 12.92 degrees as the source is tuned over an 80-nm bandwidth. The values for calculated maximum optical beam divergance, required wavelength resolution, beam-pointing accuracy, and measured scanner insertion loss are 1.076 mrad, 0.172 nm, 0.06 mrad, and 4.88 dB, respectively.

  19. Portable CT scanners for use on live trees and standing columns

    International Nuclear Information System (INIS)

    Onoe, M.; Tsao, J.W.; Yamada, H.; Nakamura, H.; Kogure, J.; Kawamura, H.; Isono, E.; Maeda, Y.; Matsumoto, S.

    1985-01-01

    Computed tomography (CT) is a technique to reconstruct a crosssection of a test object from multiple projections obtained using e.g. x-rays. A large number of medical CT scanners and a few industrial CT scanners have been used. Most of these scanners are fixed installations. In contrast, we developed portable CT scanners for nondestructive testing of live trees and standing building columns in field environment. The resolution of these scanners is high enough to reveal details of annual rings of trees and timbers. The scanners have been useful in a wide range of applications. This paper presents two types of scanners with small and large apertures, a system for quick look of reconstruction and a few examples of applications

  20. Active Multispectral Band Selection and Reflectance Measurement System

    National Research Council Canada - National Science Library

    Rennich, Bradley

    1999-01-01

    .... To aid in the selection of these bands, a novel multispectral band selection technique is presented based on the cross-correlation of the material class reflectance spectra over a wavelength range of 1 - 5 microns...

  1. Multispectral colour analysis for quantitative evaluation of pseudoisochromatic color deficiency tests

    Science.gov (United States)

    Ozolinsh, Maris; Fomins, Sergejs

    2010-11-01

    Multispectral color analysis was used for spectral scanning of Ishihara and Rabkin color deficiency test book images. It was done using tunable liquid-crystal LC filters built in the Nuance II analyzer. Multispectral analysis keeps both, information on spatial content of tests and on spectral content. Images were taken in the range of 420-720nm with a 10nm step. We calculated retina neural activity charts taking into account cone sensitivity functions, and processed charts in order to find the visibility of latent symbols in color deficiency plates using cross-correlation technique. In such way the quantitative measure is found for each of diagnostics plate for three different color deficiency carrier types - protanopes, deutanopes and tritanopes. Multispectral color analysis allows to determine the CIE xyz color coordinates of pseudoisochromatic plate design elements and to perform statistical analysis of these data to compare the color quality of available color deficiency test books.

  2. Multispectral imaging reveals biblical-period inscription unnoticed for half a century.

    Directory of Open Access Journals (Sweden)

    Shira Faigenbaum-Golovin

    Full Text Available Most surviving biblical period Hebrew inscriptions are ostraca-ink-on-clay texts. They are poorly preserved and once unearthed, fade rapidly. Therefore, proper and timely documentation of ostraca is essential. Here we show a striking example of a hitherto invisible text on the back side of an ostracon revealed via multispectral imaging. This ostracon, found at the desert fortress of Arad and dated to ca. 600 BCE (the eve of Judah's destruction by Nebuchadnezzar, has been on display for half a century. Its front side has been thoroughly studied, while its back side was considered blank. Our research revealed three lines of text on the supposedly blank side and four "new" lines on the front side. Our results demonstrate the need for multispectral image acquisition for both sides of all ancient ink ostraca. Moreover, in certain cases we recommend employing multispectral techniques for screening newly unearthed ceramic potsherds prior to disposal.

  3. Multimodality Registration without a Dedicated Multimodality Scanner

    Directory of Open Access Journals (Sweden)

    Bradley J. Beattie

    2007-03-01

    Full Text Available Multimodality scanners that allow the acquisition of both functional and structural image sets on a single system have recently become available for animal research use. Although the resultant registered functional/structural image sets can greatly enhance the interpretability of the functional data, the cost of multimodality systems can be prohibitive, and they are often limited to two modalities, which generally do not include magnetic resonance imaging. Using a thin plastic wrap to immobilize and fix a mouse or other small animal atop a removable bed, we are able to calculate registrations between all combinations of four different small animal imaging scanners (positron emission tomography, single-photon emission computed tomography, magnetic resonance, and computed tomography [CT] at our disposal, effectively equivalent to a quadruple-modality scanner. A comparison of serially acquired CT images, with intervening acquisitions on other scanners, demonstrates the ability of the proposed procedures to maintain the rigidity of an anesthetized mouse during transport between scanners. Movement of the bony structures of the mouse was estimated to be 0.62 mm. Soft tissue movement was predominantly the result of the filling (or emptying of the urinary bladder and thus largely constrained to this region. Phantom studies estimate the registration errors for all registration types to be less than 0.5 mm. Functional images using tracers targeted to known structures verify the accuracy of the functional to structural registrations. The procedures are easy to perform and produce robust and accurate results that rival those of dedicated multimodality scanners, but with more flexible registration combinations and while avoiding the expense and redundancy of multimodality systems.

  4. Utilization pattern of whole body computed tomography scanner

    International Nuclear Information System (INIS)

    Youn, Chul Ho; Lee, Sang Suk

    1986-01-01

    Computed tomography scanner (CT scanner) is one of the most expensive and sophisticated diagnostic tool and has already been utilized in many hospitals in Korea. The price as well as operating costs of CT scanner is so expensive as to regulate its installment by government even in the United States. In order to identify the efficient utilization of the CT scanner, the utilization pattern for CT scanning was analyzed at three general hospital in seoul. The results are as follows: 1. Five out of one thousand outpatients and five out of one hundred inpatients were CT scanned. 2. Eighty percent of patients who were scanned were those of inpatients of the hospitals where the scanned are installed. 3. Head standings constitute 45.6 percent of examinations, internal medicine 63.8 percent, and 38.5 percent neurosurgery respectively. 4. The rate of indication for CT scanning showed no statistically significant difference between insured and non-insured groups. 5. Computed tomography scanner units were operated 5.5 days a week in average and full operation rate was 79.5% in average. 6. The major diagnoses mode by head scanning were: hematoma (56.7%), infarction (12.6%), tumor (8.2%), and hydrocephalus (4.4%). 7. Number of patients taken CT Scanning was 43 persons a week in average for each whole body scanner unit

  5. Input Scanners: A Growing Impact In A Diverse Marketplace

    Science.gov (United States)

    Marks, Kevin E.

    1989-08-01

    Just as newly invented photographic processes revolutionized the printing industry at the turn of the century, electronic imaging has affected almost every computer application today. To completely emulate traditionally mechanical means of information handling, computer based systems must be able to capture graphic images. Thus, there is a widespread need for the electronic camera, the digitizer, the input scanner. This paper will review how various types of input scanners are being used in many diverse applications. The following topics will be covered: - Historical overview of input scanners - New applications for scanners - Impact of scanning technology on select markets - Scanning systems issues

  6. SCT-4800T whole body X-ray CT scanner

    International Nuclear Information System (INIS)

    Okumura, Yoshitaka; Sato, Yukio; Kuwahara, Hiroshi

    1994-01-01

    A whole body X-ray CT scanner, the SCT-4800T (trade name: INTELLECT series), has been developed. This system is the first CT scanner that is combined with general radiographic functions. The general radiographic functions include a patient couch with film casette and several tube support systems along with the CT scanner. This newly designed CT scanner also features a compact and light-weight gantry with a 700 mm diameter apperture and user-friendly operater's console. The SCT-4800T brings a new level of patient and operator comfort to the emergency radiology examination site. (author)

  7. UAV MULTISPECTRAL SURVEY TO MAP SOIL AND CROP FOR PRECISION FARMING APPLICATIONS

    Directory of Open Access Journals (Sweden)

    G. Sona

    2016-06-01

    Full Text Available New sensors mounted on UAV and optimal procedures for survey, data acquisition and analysis are continuously developed and tested for applications in precision farming. Procedures to integrate multispectral aerial data about soil and crop and ground-based proximal geophysical data are a recent research topic aimed to delineate homogeneous zones for the management of agricultural inputs (i.e., water, nutrients. Multispectral and multitemporal orthomosaics were produced over a test field (a 100 m x 200 m plot within a maize field, to map vegetation and soil indices, as well as crop heights, with suitable ground resolution. UAV flights were performed in two moments during the crop season, before sowing on bare soil, and just before flowering when maize was nearly at the maximum height. Two cameras, for color (RGB and false color (NIR-RG images, were used. The images were processed in Agisoft Photoscan to produce Digital Surface Model (DSM of bare soil and crop, and multispectral orthophotos. To overcome some difficulties in the automatic searching of matching points for the block adjustment of the crop image, also the scientific software developed by Politecnico of Milan was used to enhance images orientation. Surveys and image processing are described, as well as results about classification of multispectral-multitemporal orthophotos and soil indices.

  8. Exploiting physical constraints for multi-spectral exo-planet detection

    Science.gov (United States)

    Thiébaut, Éric; Devaney, Nicholas; Langlois, Maud; Hanley, Kenneth

    2016-07-01

    We derive a physical model of the on-axis PSF for a high contrast imaging system such as GPI or SPHERE. This model is based on a multi-spectral Taylor series expansion of the diffraction pattern and predicts that the speckles should be a combination of spatial modes with deterministic chromatic magnification and weighting. We propose to remove most of the residuals by fitting this model on a set of images at multiple wavelengths and times. On simulated data, we demonstrate that our approach achieves very good speckle suppression without additional heuristic parameters. The residual speckles1, 2 set the most serious limitation in the detection of exo-planets in high contrast coronographic images provided by instruments such as SPHERE3 at the VLT, GPI4, 5 at Gemini, or SCExAO6 at Subaru. A number of post-processing methods have been proposed to remove as much as possible of the residual speckles while preserving the signal from the planets. These methods exploit the fact that the speckles and the planetary signal have different temporal and spectral behaviors. Some methods like LOCI7 are based on angular differential imaging8 (ADI), spectral differential imaging9, 10 (SDI), or on a combination of ADI and SDI.11 Instead of working on image differences, we propose to tackle the exo-planet detection as an inverse problem where a model of the residual speckles is fit on the set of multi-spectral images and, possibly, multiple exposures. In order to reduce the number of degrees of freedom, we impose specific constraints on the spatio-spectral distribution of stellar speckles. These constraints are deduced from a multi-spectral Taylor series expansion of the diffraction pattern for an on-axis source which implies that the speckles are a combination of spatial modes with deterministic chromatic magnification and weighting. Using simulated data, the efficiency of speckle removal by fitting the proposed multi-spectral model is compared to the result of using an approximation

  9. Developments in holographic-based scanner designs

    Science.gov (United States)

    Rowe, David M.

    1997-07-01

    Holographic-based scanning systems have been used for years in the high resolution prepress markets where monochromatic lasers are generally utilized. However, until recently, due to the dispersive properties of holographic optical elements (HOEs), along with the high cost associated with recording 'master' HOEs, holographic scanners have not been able to penetrate major scanning markets such as the laser printer and digital copier markets, low to mid-range imagesetter markets, and the non-contact inspection scanner market. Each of these markets has developed cost effective laser diode based solutions using conventional scanning approaches such as polygon/f-theta lens combinations. In order to penetrate these markets, holographic-based systems must exhibit low cost and immunity to wavelength shifts associated with laser diodes. This paper describes recent developments in the design of holographic scanners in which multiple HOEs, each possessing optical power, are used in conjunction with one curved mirror to passively correct focal plane position errors and spot size changes caused by the wavelength instability of laser diodes. This paper also describes recent advancements in low cost production of high quality HOEs and curved mirrors. Together these developments allow holographic scanners to be economically competitive alternatives to conventional devices in every segment of the laser scanning industry.

  10. Multi-spectral lifetime imaging: methods and applications

    NARCIS (Netherlands)

    Fereidouni, F.

    2013-01-01

    The aim of this PhD project is to further develop multispectral life time imaging hardware and analyses methods. The hardware system, Lambda-Tau, generates a considerable amount of data at high speed. To fully exploit the power of this new hardware, fast and reliable data analyses methods are

  11. Circumference estimation using 3D-whole body scanners and shadow scanner

    NARCIS (Netherlands)

    Daanen, H.A.M.

    1998-01-01

    Clothing designers and manufacturers use traditional body dimensions as their basis. When 3D-whole body scanners are introduced to determine the body dimensions, a conversion has to be made, since scan determined circumference measures are slightly larger than the traditional values. This pilot

  12. Manually operated small envelope scanner system

    Energy Technology Data Exchange (ETDEWEB)

    Sword, Charles Keith

    2017-04-18

    A scanner system and method for acquisition of position-based ultrasonic inspection data are described. The scanner system includes an inspection probe and a first non-contact linear encoder having a first sensor and a first scale to track inspection probe position. The first sensor is positioned to maintain a continuous non-contact interface between the first sensor and the first scale and to maintain a continuous alignment of the first sensor with the inspection probe. The scanner system may be used to acquire two-dimensional inspection probe position data by including a second non-contact linear encoder having a second sensor and a second scale, the second sensor positioned to maintain a continuous non-contact interface between the second sensor and the second scale and to maintain a continuous alignment of the second sensor with the first sensor.

  13. Particle discrimination by an automatic scanner for nuclear emulsion plates

    International Nuclear Information System (INIS)

    Heinecke, W.; Fischer, B.E.

    1976-01-01

    An automatic scanner for nuclear emulsion plates has been improved by adding particle discrimination. By determination of the mean luminosity of tracks in darkfield illumination in addition to the track length a clear discrimination has been obtained, at least for lighter particles. The scanning speed of the original automatic scanner has not been reduced. The scanner works up to 200 times faster than a human scanner. Besides the particle discrimination the determination of the mean track luminosity led to a lower perturbation sensitivity with respect to a high background of accidentally developed silvergrains, scratches in emulsion etc. The reproducibility of the results obtained by the automatic scanner is better than 5%. (Auth.)

  14. Multispectral Microimager for Astrobiology

    Science.gov (United States)

    Sellar, R. Glenn; Farmer, Jack D.; Kieta, Andrew; Huang, Julie

    2006-01-01

    A primary goal of the astrobiology program is the search for fossil records. The astrobiology exploration strategy calls for the location and return of samples indicative of environments conducive to life, and that best capture and preserve biomarkers. Successfully returning samples from environments conducive to life requires two primary capabilities: (1) in situ mapping of the mineralogy in order to determine whether the desired minerals are present; and (2) nondestructive screening of samples for additional in-situ testing and/or selection for return to laboratories for more in-depth examination. Two of the most powerful identification techniques are micro-imaging and visible/infrared spectroscopy. The design and test results are presented from a compact rugged instrument that combines micro-imaging and spectroscopic capability to provide in-situ analysis, mapping, and sample screening capabilities. Accurate reflectance spectra should be a measure of reflectance as a function of wavelength only. Other compact multispectral microimagers use separate LEDs (light-emitting diodes) for each wavelength and therefore vary the angles of illumination when changing wavelengths. When observing a specularly-reflecting sample, this produces grossly inaccurate spectra due to the variation in the angle of illumination. An advanced design and test results are presented for a multispectral microimager which demonstrates two key advances relative to previous LED-based microimagers: (i) acquisition of actual reflectance spectra in which the flux is a function of wavelength only, rather than a function of both wavelength and illumination geometry; and (ii) increase in the number of spectral bands to eight bands covering a spectral range of 468 to 975 nm.

  15. Multispectral open-air intraoperative fluorescence imaging.

    Science.gov (United States)

    Behrooz, Ali; Waterman, Peter; Vasquez, Kristine O; Meganck, Jeff; Peterson, Jeffrey D; Faqir, Ilias; Kempner, Joshua

    2017-08-01

    Intraoperative fluorescence imaging informs decisions regarding surgical margins by detecting and localizing signals from fluorescent reporters, labeling targets such as malignant tissues. This guidance reduces the likelihood of undetected malignant tissue remaining after resection, eliminating the need for additional treatment or surgery. The primary challenges in performing open-air intraoperative fluorescence imaging come from the weak intensity of the fluorescence signal in the presence of strong surgical and ambient illumination, and the auto-fluorescence of non-target components, such as tissue, especially in the visible spectral window (400-650 nm). In this work, a multispectral open-air fluorescence imaging system is presented for translational image-guided intraoperative applications, which overcomes these challenges. The system is capable of imaging weak fluorescence signals with nanomolar sensitivity in the presence of surgical illumination. This is done using synchronized fluorescence excitation and image acquisition with real-time background subtraction. Additionally, the system uses a liquid crystal tunable filter for acquisition of multispectral images that are used to spectrally unmix target fluorescence from non-target auto-fluorescence. Results are validated by preclinical studies on murine models and translational canine oncology models.

  16. submitter Dynamical Models of a Wire Scanner

    CERN Document Server

    Barjau, Ana; Dehning, Bernd

    2016-01-01

    The accuracy of the beam profile measurements achievable by the current wire scanners at CERN is limited by the vibrations of their mechanical parts. In particular, the vibrations of the carbon wire represent the major source of wire position uncertainty which limits the beam profile measurement accuracy. In the coming years, due to the Large Hadron Collider (LHC) luminosity upgrade, a wire traveling speed up to 20 $m s^{−1}$ and a position measurement accuracy of the order of 1 μm will be required. A new wire scanner design based on the understanding of the wire vibration origin is therefore needed. We present the models developed to understand the main causes of the wire vibrations observed in an existing wire scanner. The development and tuning of those models are based on measurements and tests performed on that CERN proton synchrotron (PS) scanner. The final model for the (wire + fork) system has six degrees-of-freedom (DOF). The wire equations contain three different excitation terms: inertia...

  17. Preliminary data for the 20 May 1974, simultaneous evaluation of remote sensors experiment. [water pollution monitoring

    Science.gov (United States)

    Johnson, R. W.; Batten, C. E.; Bowker, D. E.; Bressette, W. E.; Grew, G. W.

    1975-01-01

    Several remote sensors were simultaneously used to collect data over the tidal James River from Hopewell to Norfolk, Virginia. Sensors evaluated included the Multichannel-Ocean Color Sensor, multispectral scanners, and multispectral photography. Ground truth measurements and remotely sensed data are given. Preliminary analysis indicates that suspended sediment and concentrated industrial effluent are observable from all sensors.

  18. Myocardium scintigraphy and coronaries scanner: results and respective contribution of these two examinations; Scintigraphie myocardique et scanner coronaire: resultats et apport respectif des deux examens

    Energy Technology Data Exchange (ETDEWEB)

    Songy, B.; Balestrini, V.; Sablayrolles, J.L.; Vigoni, F.; Lussato, D. [Centre cardiologique du Nord (CCN), Saint-Denis, (France); Faccio, F. [fondation San Geronimo, Santa Fe, (Argentina)

    2009-05-15

    The objective were to evaluate the results and the respective contribution of the myocardium scintigraphy and the coro-scanner. It exists an excellent correlation between a normal scanner and a normal scintigraphy (97%). 30% of patients having non tight stenosis at scanner and 60% of these ones having tight stenosis have a scintigraphy ischemia; An abnormal scanner, whatever be the the degree of stenosis must be completed by a test of myocardium ischemia. The actual limitations of the coro-scanner (64 gills) are in relation with its spatial resolution (quantification) and temporal resolution (right coronary). The choice of the diagnosis examination to realize in first intention must depend on the age and prevalence of the coronary disease. (N.C.)

  19. APLIKASI INFO HALAL MENGGUNAKAN BARCODE SCANNER UNTUK SMARTPHONE ANDROID

    Directory of Open Access Journals (Sweden)

    Beki Subeki

    2016-05-01

    Full Text Available Abstract – In the production and trade of food products in the era of globalization, people are consuming, especially Muslims need to be given the knowledge, information and access to adequate in order to obtain the correct information about the halal status of products bought. The use of barcode scanners halal product information using the mobile platform is effective and useful for the public to find out information on a product. Barcode scanners can be read by optical scanners called barcode readers or scanned from an image by special software. In Indonesia, most mobile phones have the scanning software for 2D codes, and similar devices available via smartphone.   Keywords : Barcode Scanner, Mobile Platform, Halal Products, Smartphone     Abstrak - Dalam kegiatan produksi dan perdagangan produk pangan di era globalisasi ini, masyarakat yang mengkonsumsi, khususnya umat islam perlu diberikan pengetahuan tentang kehalalan produk, informasi dan akses yang memadai agar memperoleh informasi yang benar tentang status kehalalan produk yang dibelinya. Penggunaan barcode scanner informasi produk halal dengan menggunakan mobile platform dinilai cukup efektif dan berguna bagi masyarakat luas untuk mengetahui informasi sebuah produk. Barcode scanner dapat dibaca oleh pemindai optik yang disebut pembaca kode batang atau dipindai dari sebuah gambar oleh perangkat lunak khusus. Di Indonesia, kebanyakan telepon genggam memiliki perangkat lunak pemindai untuk kode 2D, dan perangkat sejenis tersedia melalui smartphone.   Kata Kunci: Barcode Scanner, Mobile Platform, Produk Halal, Smartphone

  20. Fusion of multispectral and panchromatic images using multirate filter banks

    Institute of Scientific and Technical Information of China (English)

    Wang Hong; Jing Zhongliang; Li Jianxun

    2005-01-01

    In this paper, an image fusion method based on the filter banks is proposed for merging a high-resolution panchromatic image and a low-resolution multispectral image. Firstly, the filter banks are designed to merge different signals with minimum distortion by using cosine modulation. Then, the filter banks-based image fusion is adopted to obtain a high-resolution multispectral image that combines the spectral characteristic of low-resolution data with the spatial resolution of the panchromatic image. Finally, two different experiments and corresponding performance analysis are presented. Experimental results indicate that the proposed approach outperforms the HIS transform, discrete wavelet transform and discrete wavelet frame.

  1. A simple scanner for Compton tomography

    CERN Document Server

    Cesareo, R; Brunetti, A; Golosio, B; Castellano, A

    2002-01-01

    A first generation CT-scanner was designed and constructed to carry out Compton images. This CT-scanner is composed of a 80 kV, 5 mA X-ray tube and a NaI(Tl) X-ray detector; the tube is strongly collimated, generating a X-ray beam of 2 mm diameter, whilst the detector is not collimated to collect Compton photons from the whole irradiated cylinder. The performances of the equipment were tested contemporaneous transmission and Compton images.

  2. MRO CRISM MULTISPECTRAL REDUCED DATA RECORD V1.0

    Data.gov (United States)

    National Aeronautics and Space Administration — This dataset contains CRISM Multispectral Reduced Data Records (MRDRs). MRDRs are organized into 30 subdirectories named by the Mars Chart containing the MRDR, e.g....

  3. Automated detection and mapping of crown discolouration caused by jack pine budworm with 2.5 m resolution multispectral imagery

    Science.gov (United States)

    Leckie, Donald G.; Cloney, Ed; Joyce, Steve P.

    2005-05-01

    Jack pine budworm ( Choristoneura pinus pinus (Free.)) is a native insect defoliator of mainly jack pine ( Pinus banksiana Lamb.) in North America east of the Rocky Mountains. Periodic outbreaks of this insect, which generally last two to three years, can cause growth loss and mortality and have an important impact ecologically and economically in terms of timber production and harvest. The jack pine budworm prefers to feed on current year needles. Their characteristic feeding habits cause discolouration or reddening of the canopy. This red colouration is used to map the distribution and intensity of defoliation that has taken place that year (current defoliation). An accurate and consistent map of the distribution and intensity of budworm defoliation (as represented by the red discolouration) at the stand and within stand level is desirable. Automated classification of multispectral imagery, such as is available from airborne and new high resolution satellite systems, was explored as a viable tool for objectively classifying current discolouration. Airborne multispectral imagery was acquired at a 2.5 m resolution with the Multispectral Electro-optical Imaging Sensor (MEIS). It recorded imagery in six nadir looking spectral bands specifically designed to detect discolouration caused by budworm and a near-infrared band viewing forward at 35° was also used. A 2200 nm middle infrared image was acquired with a Daedalus scanner. Training and test areas of different levels of discolouration were created based on field observations and a maximum likelihood supervized classification was used to estimate four classes of discolouration (nil-trace, light, moderate and severe). Good discrimination was achieved with an overall accuracy of 84% for the four discolouration levels. The moderate discolouration class was the poorest at 73%, because of confusion with both the severe and light classes. Accuracy on a stand basis was also good, and regional and within stand

  4. Multispectral and polarimetric photodetection using a plasmonic metasurface

    Science.gov (United States)

    Pelzman, Charles; Cho, Sang-Yeon

    2018-01-01

    We present a metasurface-integrated Si 2-D CMOS sensor array for multispectral and polarimetric photodetection applications. The demonstrated sensor is based on the polarization selective extraordinary optical transmission from periodic subwavelength nanostructures, acting as artificial atoms, known as meta-atoms. The meta-atoms were created by patterning periodic rectangular apertures that support optical resonance at the designed spectral bands. By spatially separating meta-atom clusters with different lattice constants and orientations, the demonstrated metasurface can convert the polarization and spectral information of an optical input into a 2-D intensity pattern. As a proof-of-concept experiment, we measured the linear components of the Stokes parameters directly from captured images using a CMOS camera at four spectral bands. Compared to existing multispectral polarimetric sensors, the demonstrated metasurface-integrated CMOS system is compact and does not require any moving components, offering great potential for advanced photodetection applications.

  5. LANDSAT 8 MULTISPECTRAL AND PANSHARPENED IMAGERY PROCESSING ON THE STUDY OF CIVIL ENGINEERING ISSUES

    Directory of Open Access Journals (Sweden)

    M. A. Lazaridou

    2016-06-01

    Full Text Available Scientific and professional interests of civil engineering mainly include structures, hydraulics, geotechnical engineering, environment, and transportation issues. Topics included in the context of the above may concern urban environment issues, urban planning, hydrological modelling, study of hazards and road construction. Land cover information contributes significantly on the study of the above subjects. Land cover information can be acquired effectively by visual image interpretation of satellite imagery or after applying enhancement routines and also by imagery classification. The Landsat Data Continuity Mission (LDCM – Landsat 8 is the latest satellite in Landsat series, launched in February 2013. Landsat 8 medium spatial resolution multispectral imagery presents particular interest in extracting land cover, because of the fine spectral resolution, the radiometric quantization of 12bits, the capability of merging the high resolution panchromatic band of 15 meters with multispectral imagery of 30 meters as well as the policy of free data. In this paper, Landsat 8 multispectral and panchromatic imageries are being used, concerning surroundings of a lake in north-western Greece. Land cover information is extracted, using suitable digital image processing software. The rich spectral context of the multispectral image is combined with the high spatial resolution of the panchromatic image, applying image fusion – pansharpening, facilitating in this way visual image interpretation to delineate land cover. Further processing concerns supervised image classification. The classification of pansharpened image preceded multispectral image classification. Corresponding comparative considerations are also presented.

  6. Landsat 8 Multispectral and Pansharpened Imagery Processing on the Study of Civil Engineering Issues

    Science.gov (United States)

    Lazaridou, M. A.; Karagianni, A. Ch.

    2016-06-01

    Scientific and professional interests of civil engineering mainly include structures, hydraulics, geotechnical engineering, environment, and transportation issues. Topics included in the context of the above may concern urban environment issues, urban planning, hydrological modelling, study of hazards and road construction. Land cover information contributes significantly on the study of the above subjects. Land cover information can be acquired effectively by visual image interpretation of satellite imagery or after applying enhancement routines and also by imagery classification. The Landsat Data Continuity Mission (LDCM - Landsat 8) is the latest satellite in Landsat series, launched in February 2013. Landsat 8 medium spatial resolution multispectral imagery presents particular interest in extracting land cover, because of the fine spectral resolution, the radiometric quantization of 12bits, the capability of merging the high resolution panchromatic band of 15 meters with multispectral imagery of 30 meters as well as the policy of free data. In this paper, Landsat 8 multispectral and panchromatic imageries are being used, concerning surroundings of a lake in north-western Greece. Land cover information is extracted, using suitable digital image processing software. The rich spectral context of the multispectral image is combined with the high spatial resolution of the panchromatic image, applying image fusion - pansharpening, facilitating in this way visual image interpretation to delineate land cover. Further processing concerns supervised image classification. The classification of pansharpened image preceded multispectral image classification. Corresponding comparative considerations are also presented.

  7. Dual multispectral and 3D structured light laparoscope

    Science.gov (United States)

    Clancy, Neil T.; Lin, Jianyu; Arya, Shobhit; Hanna, George B.; Elson, Daniel S.

    2015-03-01

    Intraoperative feedback on tissue function, such as blood volume and oxygenation would be useful to the surgeon in cases where current clinical practice relies on subjective measures, such as identification of ischaemic bowel or tissue viability during anastomosis formation. Also, tissue surface profiling may be used to detect and identify certain pathologies, as well as diagnosing aspects of tissue health such as gut motility. In this paper a dual modality laparoscopic system is presented that combines multispectral reflectance and 3D surface imaging. White light illumination from a xenon source is detected by a laparoscope-mounted fast filter wheel camera to assemble a multispectral image (MSI) cube. Surface shape is then calculated using a spectrally-encoded structured light (SL) pattern detected by the same camera and triangulated using an active stereo technique. Images of porcine small bowel were acquired during open surgery. Tissue reflectance spectra were acquired and blood volume was calculated at each spatial pixel across the bowel wall and mesentery. SL features were segmented and identified using a `normalised cut' algoritm and the colour vector of each spot. Using the 3D geometry defined by the camera coordinate system the multispectral data could be overlaid onto the surface mesh. Dual MSI and SL imaging has the potential to provide augmented views to the surgeon supplying diagnostic information related to blood supply health and organ function. Future work on this system will include filter optimisation to reduce noise in tissue optical property measurement, and minimise spot identification errors in the SL pattern.

  8. Remote sensing of wetlands at the Savannah River Plant

    International Nuclear Information System (INIS)

    Christensen, E.J.; Jensen, J.R.; Sharitz, R.R.

    1985-01-01

    The Savannah River Plant (SRP) occupies about 300 sq mi along a 10-mile stretch of the Savannah River. Large areas of wetlands cover the site, especially along tributary stream floodplains and the Savannah River. Some of these areas have been altered by cooling water discharges from nuclear production reactors onsite. To assess the effects of current and future plant operations on SRP and regional wetlands, an accurate quantitative survey was needed. Several studies were initiated to provide wetland acreage and distribution information: regional wetland inventories were provided from an analysis of LANDSAT multispectral scanner (MSS) satellite data. Wetlands were mapped throughout the entire Savannah River watershed and in the Savannah River floodplain. SRP wetlands were identified using a combination of LANDSAT MSS and Thematic Mapper satellite data and aerial photography. Wetlands in the SRP Savannah River swamp and thermally affected areas were mapped using high resolution MSS data collected from a low-flying aircraft. Vegetation communities in areas receiving cooling water discharges were then compared to surface temperatures measured from the airborne scanner at the same time to evaluate plant temperature tolerance. Historic changes to SRP wetlands from cooling water discharges were tabulated using aerial photography

  9. UTILIZING SAR AND MULTISPECTRAL INTEGRATED DATA FOR EMERGENCY RESPONSE

    Directory of Open Access Journals (Sweden)

    S. Havivi

    2016-06-01

    Full Text Available Satellite images are used widely in the risk cycle to understand the exposure, refine hazard maps and quickly provide an assessment after a natural or man-made disaster. Though there are different types of satellite images (e.g. optical, radar these have not been combined for risk assessments. The characteristics of different remote sensing data type may be extremely valuable for monitoring and evaluating the impacts of disaster events, to extract additional information thus making it available for emergency situations. To base this approach, two different change detection methods, for two different sensor's data were used: Coherence Change Detection (CCD for SAR data and Covariance Equalization (CE for multispectral imagery. The CCD provides an identification of the stability of an area, and shows where changes have occurred. CCD shows subtle changes with an accuracy of several millimetres to centimetres. The CE method overcomes the atmospheric effects differences between two multispectral images, taken at different times. Therefore, areas that had undergone a major change can be detected. To achieve our goals, we focused on the urban areas affected by the tsunami event in Sendai, Japan that occurred on March 11, 2011 which affected the surrounding area, coastline and inland. High resolution TerraSAR-X (TSX and Landsat 7 images, covering the research area, were acquired for the period before and after the event. All pre-processed and processed according to each sensor. Both results, of the optical and SAR algorithms, were combined by resampling the spatial resolution of the Multispectral data to the SAR resolution. This was applied by spatial linear interpolation. A score representing the damage level in both products was assigned. The results of both algorithms, high level of damage is shown in the areas closer to the sea and shoreline. Our approach, combining SAR and multispectral images, leads to more reliable information and provides a

  10. Oximetry using multispectral imaging: theory and application

    Science.gov (United States)

    MacKenzie, Lewis E.; Harvey, Andrew R.

    2018-06-01

    Multispectral imaging (MSI) is a technique for measurement of blood oxygen saturation in vivo that can be applied using various imaging modalities to provide new insights into physiology and disease development. This tutorial aims to provide a thorough introduction to the theory and application of MSI oximetry for researchers new to the field, whilst also providing detailed information for more experienced researchers. The optical theory underlying two-wavelength oximetry, three-wavelength oximetry, pulse oximetry, and multispectral oximetry algorithms are described in detail. The varied challenges of applying MSI oximetry to in vivo applications are outlined and discussed, covering: the optical properties of blood and tissue, optical paths in blood vessels, tissue auto-fluorescence, oxygen diffusion, and common oximetry artefacts. Essential image processing techniques for MSI are discussed, in particular, image acquisition, image registration strategies, and blood vessel line profile fitting. Calibration and validation strategies for MSI are discussed, including comparison techniques, physiological interventions, and phantoms. The optical principles and unique imaging capabilities of various cutting-edge MSI oximetry techniques are discussed, including photoacoustic imaging, spectroscopic optical coherence tomography, and snapshot MSI.

  11. A flexible and wearable terahertz scanner

    Science.gov (United States)

    Suzuki, D.; Oda, S.; Kawano, Y.

    2016-12-01

    Imaging technologies based on terahertz (THz) waves have great potential for use in powerful non-invasive inspection methods. However, most real objects have various three-dimensional curvatures and existing THz technologies often encounter difficulties in imaging such configurations, which limits the useful range of THz imaging applications. Here, we report the development of a flexible and wearable THz scanner based on carbon nanotubes. We achieved room-temperature THz detection over a broad frequency band ranging from 0.14 to 39 THz and developed a portable THz scanner. Using this scanner, we performed THz imaging of samples concealed behind opaque objects, breakages and metal impurities of a bent film and multi-view scans of a syringe. We demonstrated a passive biometric THz scan of a human hand. Our results are expected to have considerable implications for non-destructive and non-contact inspections, such as medical examinations for the continuous monitoring of health conditions.

  12. A Multispectral Photon-Counting Double Random Phase Encoding Scheme for Image Authentication

    Directory of Open Access Journals (Sweden)

    Faliu Yi

    2014-05-01

    Full Text Available In this paper, we propose a new method for color image-based authentication that combines multispectral photon-counting imaging (MPCI and double random phase encoding (DRPE schemes. The sparsely distributed information from MPCI and the stationary white noise signal from DRPE make intruder attacks difficult. In this authentication method, the original multispectral RGB color image is down-sampled into a Bayer image. The three types of color samples (red, green and blue color in the Bayer image are encrypted with DRPE and the amplitude part of the resulting image is photon counted. The corresponding phase information that has nonzero amplitude after photon counting is then kept for decryption. Experimental results show that the retrieved images from the proposed method do not visually resemble their original counterparts. Nevertheless, the original color image can be efficiently verified with statistical nonlinear correlations. Our experimental results also show that different interpolation algorithms applied to Bayer images result in different verification effects for multispectral RGB color images.

  13. A multispectral photon-counting double random phase encoding scheme for image authentication.

    Science.gov (United States)

    Yi, Faliu; Moon, Inkyu; Lee, Yeon H

    2014-05-20

    In this paper, we propose a new method for color image-based authentication that combines multispectral photon-counting imaging (MPCI) and double random phase encoding (DRPE) schemes. The sparsely distributed information from MPCI and the stationary white noise signal from DRPE make intruder attacks difficult. In this authentication method, the original multispectral RGB color image is down-sampled into a Bayer image. The three types of color samples (red, green and blue color) in the Bayer image are encrypted with DRPE and the amplitude part of the resulting image is photon counted. The corresponding phase information that has nonzero amplitude after photon counting is then kept for decryption. Experimental results show that the retrieved images from the proposed method do not visually resemble their original counterparts. Nevertheless, the original color image can be efficiently verified with statistical nonlinear correlations. Our experimental results also show that different interpolation algorithms applied to Bayer images result in different verification effects for multispectral RGB color images.

  14. Design of active-neutron fuel rod scanner

    International Nuclear Information System (INIS)

    Griffith, G.W.; Menlove, H.O.

    1996-01-01

    An active-neutron fuel rod scanner has been designed for the assay of fissile materials in mixed oxide fuel rods. A 252 Cf source is located at the center of the scanner very near the through hole for the fuel rods. Spontaneous fission neutrons from the californium are moderated and induce fissions within the passing fuel rod. The rod continues past a combined gamma-ray and neutron shield where delayed gamma rays above 1 MeV are detected. We used the Monte Carlo code MCNP to design the scanner and review optimum materials and geometries. An inhomogeneous beryllium, graphite, and polyethylene moderator has been designed that uses source neutrons much more efficiently than assay systems using polyethylene moderators. Layers of borated polyethylene and tungsten are used to shield the detectors. Large NaI(Tl) detectors were selected to measure the delayed gamma rays. The enrichment zones of a thermal reactor fuel pin could be measured to within 1% counting statistics for practical rod speeds. Applications of the rod scanner include accountability of fissile material for safeguards applications, quality control of the fissile content in a fuel rod, and the verification of reactivity potential for mixed oxide fuels. (orig.)

  15. Generating Multispectral VIIRS Imagery in Near Real-Time for Use by the National Weather Service in Alaska

    Science.gov (United States)

    Broderson, D.; Dierking, C.; Stevens, E.; Heinrichs, T. A.; Cherry, J. E.

    2016-12-01

    The Geographic Information Network of Alaska (GINA) at the University of Alaska Fairbanks (UAF) uses two direct broadcast antennas to receive data from a number of polar-orbiting weather satellites, including the Suomi National Polar Partnership (S-NPP) satellite. GINA uses data from S-NPP's Visible Infrared Imaging Radiometer Suite (VIIRS) to generate a variety of multispectral imagery products developed with the needs of the National Weather Service operational meteorologist in mind. Multispectral products have two primary advantages over single-channel products. First, they can more clearly highlight some terrain and meteorological features which are less evident in the component single channels. Second, multispectral present the information from several bands through just one image, thereby sparing the meteorologist unnecessary time interrogating the component single bands individually. With 22 channels available from the VIIRS instrument, the number of possible multispectral products is theoretically huge. A small number of products will be emphasized in this presentation, with the products chosen based on their proven utility in the forecasting environment. Multispectral products can be generated upstream of the end user or by the end user at their own workstation. The advantage and disadvantages of both approaches will be outlined. Lastly, the technique of improving the appearance of multispectral imagery by correcting for atmospheric reflectance at the shorter wavelengths will be described.

  16. Automated segmentation of pigmented skin lesions in multispectral imaging

    International Nuclear Information System (INIS)

    Carrara, Mauro; Tomatis, Stefano; Bono, Aldo; Bartoli, Cesare; Moglia, Daniele; Lualdi, Manuela; Colombo, Ambrogio; Santinami, Mario; Marchesini, Renato

    2005-01-01

    The aim of this study was to develop an algorithm for the automatic segmentation of multispectral images of pigmented skin lesions. The study involved 1700 patients with 1856 cutaneous pigmented lesions, which were analysed in vivo by a novel spectrophotometric system, before excision. The system is able to acquire a set of 15 different multispectral images at equally spaced wavelengths between 483 and 951 nm. An original segmentation algorithm was developed and applied to the whole set of lesions and was able to automatically contour them all. The obtained lesion boundaries were shown to two expert clinicians, who, independently, rejected 54 of them. The 97.1% contour accuracy indicates that the developed algorithm could be a helpful and effective instrument for the automatic segmentation of skin pigmented lesions. (note)

  17. Accuracy of single-abutment digital cast obtained using intraoral and cast scanners.

    Science.gov (United States)

    Lee, Jae-Jun; Jeong, Ii-Do; Park, Jin-Young; Jeon, Jin-Hun; Kim, Ji-Hwan; Kim, Woong-Chul

    2017-02-01

    Scanners are frequently used in the fabrication of dental prostheses. However, the accuracy of these scanners is variable, and little information is available. The purpose of this in vitro study was to compare the accuracy of cast scanners with that of intraoral scanners by using different image impression techniques. A poly(methyl methacrylate) master model was fabricated to replicate a maxillary first molar single-abutment tooth model. The master model was scanned with an accurate engineering scanner to obtain a true value (n=1) and with 2 intraoral scanners (CEREC Bluecam and CEREC Omnicam; n=6 each). The cast scanner scanned the master model and duplicated the dental stone cast from the master model (n=6). The trueness and precision of the data were measured using a 3-dimensional analysis program. The Kruskal-Wallis test was used to compare the different sets of scanning data, followed by a post hoc Mann-Whitney U test with a significance level modified by Bonferroni correction (α/6=.0083). The type 1 error level (α) was set at .05. The trueness value (root mean square: mean ±standard deviation) was 17.5 ±1.8 μm for the Bluecam, 13.8 ±1.4 μm for the Omnicam, 17.4 ±1.7 μm for cast scanner 1, and 12.3 ±0.1 μm for cast scanner 2. The differences between the Bluecam and the cast scanner 1 and between the Omnicam and the cast scanner 2 were not statistically significant (P>.0083), but a statistically significant difference was found between all the other pairs (POmnicam, 9.2 ±1.2 μm for cast scanner 1, and 6.9 ±2.6 μm for cast scanner 2. The differences between Bluecam and Omnicam and between Omnicam and cast scanner 1 were not statistically significant (P>.0083), but there was a statistically significant difference between all the other pairs (POmnicam in video image impression had better trueness than a cast scanner but with a similar level of precision. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by

  18. Scanner Uniformity improvements for radiochromic film analysis with matt reflectance backing

    International Nuclear Information System (INIS)

    Butson, M.; Yu, P.K.N.

    2011-01-01

    Full text: A simple and reproducible method for increasing desktop scanner uniformity for the analysis of radiochromic films is presented. Scanner uniformity, especially in the non-scan direction, for transmission scanning is well known to be problematic for radiochromic film analysis and normally corrections need to be applied. These corrections are dependant on scanner coordinates and dose level applied which complicates dosimetry procedures. This study has highlighted that using reflectance scanning in combination with a matt, white backing material instead of the conventional gloss scanner finish, substantial increases in the scanner uniformity can be achieved within 90% of the scanning area. Uniformity within ±I% over the scanning area for our epsonV700 scanner tested was found. This is compared to within ±3% for reflection scanning with the gloss backing material and within ±4% for transmission scanning. The matt backing material used was simply 5 layers of standard quality white printing paper (80 g/m It was found that 5 layers was the optimal result for backing material however most of the improvements were seen with a minimum of 3 layers. Above 5 layers, no extra benefit was seen. This may eliminate the need to perform scanner corrections for position on the desktop scanners for radiochromic film dosimetry. (author)

  19. How flatbed scanners upset accurate film dosimetry

    Science.gov (United States)

    van Battum, L. J.; Huizenga, H.; Verdaasdonk, R. M.; Heukelom, S.

    2016-01-01

    Film is an excellent dosimeter for verification of dose distributions due to its high spatial resolution. Irradiated film can be digitized with low-cost, transmission, flatbed scanners. However, a disadvantage is their lateral scan effect (LSE): a scanner readout change over its lateral scan axis. Although anisotropic light scattering was presented as the origin of the LSE, this paper presents an alternative cause. Hereto, LSE for two flatbed scanners (Epson 1680 Expression Pro and Epson 10000XL), and Gafchromic film (EBT, EBT2, EBT3) was investigated, focused on three effects: cross talk, optical path length and polarization. Cross talk was examined using triangular sheets of various optical densities. The optical path length effect was studied using absorptive and reflective neutral density filters with well-defined optical characteristics (OD range 0.2-2.0). Linear polarizer sheets were used to investigate light polarization on the CCD signal in absence and presence of (un)irradiated Gafchromic film. Film dose values ranged between 0.2 to 9 Gy, i.e. an optical density range between 0.25 to 1.1. Measurements were performed in the scanner’s transmission mode, with red-green-blue channels. LSE was found to depend on scanner construction and film type. Its magnitude depends on dose: for 9 Gy increasing up to 14% at maximum lateral position. Cross talk was only significant in high contrast regions, up to 2% for very small fields. The optical path length effect introduced by film on the scanner causes 3% for pixels in the extreme lateral position. Light polarization due to film and the scanner’s optical mirror system is the main contributor, different in magnitude for the red, green and blue channel. We concluded that any Gafchromic EBT type film scanned with a flatbed scanner will face these optical effects. Accurate dosimetry requires correction of LSE, therefore, determination of the LSE per color channel and dose delivered to the film.

  20. How flatbed scanners upset accurate film dosimetry

    International Nuclear Information System (INIS)

    Van Battum, L J; Verdaasdonk, R M; Heukelom, S; Huizenga, H

    2016-01-01

    Film is an excellent dosimeter for verification of dose distributions due to its high spatial resolution. Irradiated film can be digitized with low-cost, transmission, flatbed scanners. However, a disadvantage is their lateral scan effect (LSE): a scanner readout change over its lateral scan axis. Although anisotropic light scattering was presented as the origin of the LSE, this paper presents an alternative cause. Hereto, LSE for two flatbed scanners (Epson 1680 Expression Pro and Epson 10000XL), and Gafchromic film (EBT, EBT2, EBT3) was investigated, focused on three effects: cross talk, optical path length and polarization. Cross talk was examined using triangular sheets of various optical densities. The optical path length effect was studied using absorptive and reflective neutral density filters with well-defined optical characteristics (OD range 0.2–2.0). Linear polarizer sheets were used to investigate light polarization on the CCD signal in absence and presence of (un)irradiated Gafchromic film. Film dose values ranged between 0.2 to 9 Gy, i.e. an optical density range between 0.25 to 1.1. Measurements were performed in the scanner’s transmission mode, with red–green–blue channels. LSE was found to depend on scanner construction and film type. Its magnitude depends on dose: for 9 Gy increasing up to 14% at maximum lateral position. Cross talk was only significant in high contrast regions, up to 2% for very small fields. The optical path length effect introduced by film on the scanner causes 3% for pixels in the extreme lateral position. Light polarization due to film and the scanner’s optical mirror system is the main contributor, different in magnitude for the red, green and blue channel. We concluded that any Gafchromic EBT type film scanned with a flatbed scanner will face these optical effects. Accurate dosimetry requires correction of LSE, therefore, determination of the LSE per color channel and dose delivered to the film. (paper)

  1. Concentric circular ring and nanodisk optical antenna enhanced multispectral quantum dot infrared photodetector with spectral localization

    International Nuclear Information System (INIS)

    Zhang, Yingjie; Kemsri, Thitikorn; Li, Lin; Lu, Xuejun; Gu, Guiru

    2017-01-01

    In this paper, we report a concentric circular ring and nanodisk plasmonic optical antenna (POA) enhanced multispectral quantum dot infrared photodetector (QDIP). The circular ring and the nanodisk POA structures are designed to have plasmonic resonant wavelengths in the longwave infrared (LWIR) and the midwave infrared (MWIR) spectral regimes, respectively. The electric field ( E -field) distributions are simulated and show spectral localization due to the distinct plasmonic resonant wavelengths of the POA structures. The circular ring is found to enhance the E -fields in the nanodisk regions due to the mutual coupling. A concentric circular ring and nanodisk POA enhanced multispectral QDIP was fabricated and tested. Multispectral enhancement was observed. The enhancement is compared to that of a QDIP with only the circular ring POA structure. The experiment data agree with the simulation. The concentric circular ring and nanodisk POA provides a compact planar structure for multispectral QDIP enhancement. (paper)

  2. Was the Scanner Calibration Slide used for its intended purpose?

    Directory of Open Access Journals (Sweden)

    Zong Yaping

    2011-04-01

    Full Text Available Abstract In the article, Scanner calibration revisited, BMC Bioinformatics 2010, 11:361, Dr. Pozhitkov used the Scanner Calibration Slide, a key product of Full Moon BioSystems to generate data in his study of microarray scanner PMT response and proposed a mathematic model for PMT response 1. In the end, the author concluded that "Full Moon BioSystems calibration slides are inadequate for performing calibration," and recommended "against using these slides." We found these conclusions are seriously flawed and misleading, and his recommendation against using the Scanner Calibration Slide was not properly supported.

  3. COMPARISON OF RETINAL PATHOLOGY VISUALIZATION IN MULTISPECTRAL SCANNING LASER IMAGING.

    Science.gov (United States)

    Meshi, Amit; Lin, Tiezhu; Dans, Kunny; Chen, Kevin C; Amador, Manuel; Hasenstab, Kyle; Muftuoglu, Ilkay Kilic; Nudleman, Eric; Chao, Daniel; Bartsch, Dirk-Uwe; Freeman, William R

    2018-03-16

    To compare retinal pathology visualization in multispectral scanning laser ophthalmoscope imaging between the Spectralis and Optos devices. This retrospective cross-sectional study included 42 eyes from 30 patients with age-related macular degeneration (19 eyes), diabetic retinopathy (10 eyes), and epiretinal membrane (13 eyes). All patients underwent retinal imaging with a color fundus camera (broad-spectrum white light), the Spectralis HRA-2 system (3-color monochromatic lasers), and the Optos P200 system (2-color monochromatic lasers). The Optos image was cropped to a similar size as the Spectralis image. Seven masked graders marked retinal pathologies in each image within a 5 × 5 grid that included the macula. The average area with detected retinal pathology in all eyes was larger in the Spectralis images compared with Optos images (32.4% larger, P < 0.0001), mainly because of better visualization of epiretinal membrane and retinal hemorrhage. The average detection rate of age-related macular degeneration and diabetic retinopathy pathologies was similar across the three modalities, whereas epiretinal membrane detection rate was significantly higher in the Spectralis images. Spectralis tricolor multispectral scanning laser ophthalmoscope imaging had higher rate of pathology detection primarily because of better epiretinal membrane and retinal hemorrhage visualization compared with Optos bicolor multispectral scanning laser ophthalmoscope imaging.

  4. Multi-spectral Image Analysis for Astaxanthin Coating Classification

    DEFF Research Database (Denmark)

    Ljungqvist, Martin Georg; Ersbøll, Bjarne Kjær; Nielsen, Michael Engelbrecht

    2011-01-01

    Industrial quality inspection using image analysis on astaxanthin coating in aquaculture feed pellets is of great importance for automatic production control. In this study multi-spectral image analysis of pellets was performed using LDA, QDA, SNV and PCA on pixel level and mean value of pixels...

  5. Scanner qualification with IntenCD based reticle error correction

    Science.gov (United States)

    Elblinger, Yair; Finders, Jo; Demarteau, Marcel; Wismans, Onno; Minnaert Janssen, Ingrid; Duray, Frank; Ben Yishai, Michael; Mangan, Shmoolik; Cohen, Yaron; Parizat, Ziv; Attal, Shay; Polonsky, Netanel; Englard, Ilan

    2010-03-01

    Scanner introduction into the fab production environment is a challenging task. An efficient evaluation of scanner performance matrices during factory acceptance test (FAT) and later on during site acceptance test (SAT) is crucial for minimizing the cycle time for pre and post production-start activities. If done effectively, the matrices of base line performance established during the SAT are used as a reference for scanner performance and fleet matching monitoring and maintenance in the fab environment. Key elements which can influence the cycle time of the SAT, FAT and maintenance cycles are the imaging, process and mask characterizations involved with those cycles. Discrete mask measurement techniques are currently in use to create across-mask CDU maps. By subtracting these maps from their final wafer measurement CDU map counterparts, it is possible to assess the real scanner induced printed errors within certain limitations. The current discrete measurement methods are time consuming and some techniques also overlook mask based effects other than line width variations, such as transmission and phase variations, all of which influence the final printed CD variability. Applied Materials Aera2TM mask inspection tool with IntenCDTM technology can scan the mask at high speed, offer full mask coverage and accurate assessment of all masks induced source of errors simultaneously, making it beneficial for scanner qualifications and performance monitoring. In this paper we report on a study that was done to improve a scanner introduction and qualification process using the IntenCD application to map the mask induced CD non uniformity. We will present the results of six scanners in production and discuss the benefits of the new method.

  6. Vision Assisted Laser Scanner Navigation for Autonomous Robots

    DEFF Research Database (Denmark)

    Andersen, Jens Christian; Andersen, Nils Axel; Ravn, Ole

    2008-01-01

    This paper describes a navigation method based on road detection using both a laser scanner and a vision sensor. The method is to classify the surface in front of the robot into traversable segments (road) and obstacles using the laser scanner, this classifies the area just in front of the robot ...

  7. Supervised Classification Performance of Multispectral Images

    OpenAIRE

    Perumal, K.; Bhaskaran, R.

    2010-01-01

    Nowadays government and private agencies use remote sensing imagery for a wide range of applications from military applications to farm development. The images may be a panchromatic, multispectral, hyperspectral or even ultraspectral of terra bytes. Remote sensing image classification is one amongst the most significant application worlds for remote sensing. A few number of image classification algorithms have proved good precision in classifying remote sensing data. But, of late, due to the ...

  8. An image compression method for space multispectral time delay and integration charge coupled device camera

    International Nuclear Information System (INIS)

    Li Jin; Jin Long-Xu; Zhang Ran-Feng

    2013-01-01

    Multispectral time delay and integration charge coupled device (TDICCD) image compression requires a low-complexity encoder because it is usually completed on board where the energy and memory are limited. The Consultative Committee for Space Data Systems (CCSDS) has proposed an image data compression (CCSDS-IDC) algorithm which is so far most widely implemented in hardware. However, it cannot reduce spectral redundancy in multispectral images. In this paper, we propose a low-complexity improved CCSDS-IDC (ICCSDS-IDC)-based distributed source coding (DSC) scheme for multispectral TDICCD image consisting of a few bands. Our scheme is based on an ICCSDS-IDC approach that uses a bit plane extractor to parse the differences in the original image and its wavelet transformed coefficient. The output of bit plane extractor will be encoded by a first order entropy coder. Low-density parity-check-based Slepian—Wolf (SW) coder is adopted to implement the DSC strategy. Experimental results on space multispectral TDICCD images show that the proposed scheme significantly outperforms the CCSDS-IDC-based coder in each band

  9. Precise Multi-Spectral Dermatological Imaging

    DEFF Research Database (Denmark)

    Gomez, David Delgado; Carstensen, Jens Michael; Ersbøll, Bjarne Kjær

    2004-01-01

    In this work, an integrated imaging system to obtain accurate and reproducible multi-spectral dermatological images is proposed. The system is made up of an integrating sphere, light emitting diodes and a generic monochromatic camera. The system can collect up to 10 different spectral bands....... These spectral bands vary from ultraviolet to near infrared. The welldefined and diffuse illumination of the optically closed scene aims to avoid shadows and specular reflections. Furthermore, the system has been developed to guarantee the reproducibility of the collected images. This allows for comparative...

  10. Automated road network extraction from high spatial resolution multi-spectral imagery

    Science.gov (United States)

    Zhang, Qiaoping

    For the last three decades, the Geomatics Engineering and Computer Science communities have considered automated road network extraction from remotely-sensed imagery to be a challenging and important research topic. The main objective of this research is to investigate the theory and methodology of automated feature extraction for image-based road database creation, refinement or updating, and to develop a series of algorithms for road network extraction from high resolution multi-spectral imagery. The proposed framework for road network extraction from multi-spectral imagery begins with an image segmentation using the k-means algorithm. This step mainly concerns the exploitation of the spectral information for feature extraction. The road cluster is automatically identified using a fuzzy classifier based on a set of predefined road surface membership functions. These membership functions are established based on the general spectral signature of road pavement materials and the corresponding normalized digital numbers on each multi-spectral band. Shape descriptors of the Angular Texture Signature are defined and used to reduce the misclassifications between roads and other spectrally similar objects (e.g., crop fields, parking lots, and buildings). An iterative and localized Radon transform is developed for the extraction of road centerlines from the classified images. The purpose of the transform is to accurately and completely detect the road centerlines. It is able to find short, long, and even curvilinear lines. The input image is partitioned into a set of subset images called road component images. An iterative Radon transform is locally applied to each road component image. At each iteration, road centerline segments are detected based on an accurate estimation of the line parameters and line widths. Three localization approaches are implemented and compared using qualitative and quantitative methods. Finally, the road centerline segments are grouped into a

  11. Multispectral fingerprinting for improved in vivo cell dynamics analysis

    Directory of Open Access Journals (Sweden)

    Cooper Cameron HJ

    2010-09-01

    Full Text Available Abstract Background Tracing cell dynamics in the embryo becomes tremendously difficult when cell trajectories cross in space and time and tissue density obscure individual cell borders. Here, we used the chick neural crest (NC as a model to test multicolor cell labeling and multispectral confocal imaging strategies to overcome these roadblocks. Results We found that multicolor nuclear cell labeling and multispectral imaging led to improved resolution of in vivo NC cell identification by providing a unique spectral identity for each cell. NC cell spectral identity allowed for more accurate cell tracking and was consistent during short term time-lapse imaging sessions. Computer model simulations predicted significantly better object counting for increasing cell densities in 3-color compared to 1-color nuclear cell labeling. To better resolve cell contacts, we show that a combination of 2-color membrane and 1-color nuclear cell labeling dramatically improved the semi-automated analysis of NC cell interactions, yet preserved the ability to track cell movements. We also found channel versus lambda scanning of multicolor labeled embryos significantly reduced the time and effort of image acquisition and analysis of large 3D volume data sets. Conclusions Our results reveal that multicolor cell labeling and multispectral imaging provide a cellular fingerprint that may uniquely determine a cell's position within the embryo. Together, these methods offer a spectral toolbox to resolve in vivo cell dynamics in unprecedented detail.

  12. Multispectral Imaging of Meat Quality - Color and Texture

    DEFF Research Database (Denmark)

    Trinderup, Camilla Himmelstrup

    transformations to the CIELAB color space, the common color space within food science. The results show that meat color assessment with a multispectral imaging is a great alternative to the traditional colorimeter, i.e. the vision system meets some of the limitations that the colorimeter possesses. To mention one...

  13. Comparison of two intraoral scanners based on three-dimensional surface analysis

    Directory of Open Access Journals (Sweden)

    Kyung-Min Lee

    2018-02-01

    Full Text Available Abstract Background This in vivo study evaluated the difference of two well-known intraoral scanners used in dentistry, namely iTero (Align Technology and TRIOS (3Shape. Methods Thirty-two participants underwent intraoral scans with TRIOS and iTero scanners, as well as conventional alginate impressions. The scans obtained with the two intraoral scanners were compared with each other and were also compared with the corresponding model scans by means of three-dimensional surface analysis. The average differences between the two intraoral scans on the surfaces were evaluated by color-mapping. The average differences in the three-dimensional direction between each intraoral scans and its corresponding model scan were calculated at all points on the surfaces. Results The average differences between the two intraoral scanners were 0.057 mm at the maxilla and 0.069 mm at the mandible. Color histograms showed that local deviations between the two scanners occurred in the posterior area. As for difference in the three-dimensional direction, there was no statistically significant difference between two scanners. Conclusions Although there were some deviations in visible inspection, there was no statistical significance between the two intraoral scanners.

  14. Ionization beam scanner

    CERN Multimedia

    CERN PhotoLab

    1973-01-01

    Inner structure of an ionization beam scanner, a rather intricate piece of apparatus which permits one to measure the density distribution of the proton beam passing through it. On the outside of the tank wall there is the coil for the longitudinal magnetic field, on the inside, one can see the arrangement of electrodes creating a highly homogeneous transverse electric field.

  15. Quality assurance of computed tomography (CT) scanners

    International Nuclear Information System (INIS)

    Sankaran, A.; Sanu, K.K. . Email : a_sankaran@vsnl.com

    2004-01-01

    This article reviews the present status of research work and development of various test objects, phantoms and detector/instrumentation systems for quality assurance (QA) of computed tomography (CT) scanners, carried out in advanced countries, with emphasis on similar work done in this research centre. CT scanner is a complex equipment and routine quality control procedures are essential to the maintenance of image quality with optimum patient dose. Image quality can be ensured only through correlation between prospective monitoring of system components and tests of overall performance with standard phantoms. CT examinations contribute a large share to the population dose in advanced countries. The unique dosimetry problems in CT necessitate special techniques. This article describes a comprehensive kit developed indigenously for the following QA and type approval tests as well as for research studies on image quality/dosimetry on CT scanners

  16. A LabVIEW® based generic CT scanner control software platform.

    Science.gov (United States)

    Dierick, M; Van Loo, D; Masschaele, B; Boone, M; Van Hoorebeke, L

    2010-01-01

    UGCT, the Centre for X-ray tomography at Ghent University (Belgium) does research on X-ray tomography and its applications. This includes the development and construction of state-of-the-art CT scanners for scientific research. Because these scanners are built for very different purposes they differ considerably in their physical implementations. However, they all share common principle functionality. In this context a generic software platform was developed using LabVIEW® in order to provide the same interface and functionality on all scanners. This article describes the concept and features of this software, and its potential for tomography in a research setting. The core concept is to rigorously separate the abstract operation of a CT scanner from its actual physical configuration. This separation is achieved by implementing a sender-listener architecture. The advantages are that the resulting software platform is generic, scalable, highly efficient, easy to develop and to extend, and that it can be deployed on future scanners with minimal effort.

  17. Recovery of Forest Canopy Parameters by Inversion of Multispectral LiDAR Data

    Directory of Open Access Journals (Sweden)

    Andrew Wallace

    2012-02-01

    Full Text Available We describe the use of Bayesian inference techniques, notably Markov chain Monte Carlo (MCMC and reversible jump MCMC (RJMCMC methods, to recover forest structural and biochemical parameters from multispectral LiDAR (Light Detection and Ranging data. We use a variable dimension, multi-layered model to represent a forest canopy or tree, and discuss the recovery of structure and depth profiles that relate to photochemical properties. We first demonstrate how simple vegetation indices such as the Normalized Differential Vegetation Index (NDVI, which relates to canopy biomass and light absorption, and Photochemical Reflectance Index (PRI which is a measure of vegetation light use efficiency, can be measured from multispectral data. We further describe and demonstrate our layered approach on single wavelength real data, and on simulated multispectral data derived from real, rather than simulated, data sets. This evaluation shows successful recovery of a subset of parameters, as the complete recovery problem is ill-posed with the available data. We conclude that the approach has promise, and suggest future developments to address the current difficulties in parameter inversion.

  18. Compression of Multispectral Images with Comparatively Few Bands Using Posttransform Tucker Decomposition

    Directory of Open Access Journals (Sweden)

    Jin Li

    2014-01-01

    Full Text Available Up to now, data compression for the multispectral charge-coupled device (CCD images with comparatively few bands (MSCFBs is done independently on each multispectral channel. This compression codec is called a “monospectral compressor.” The monospectral compressor does not have a removing spectral redundancy stage. To fill this gap, we propose an efficient compression approach for MSCFBs. In our approach, the one dimensional discrete cosine transform (1D-DCT is performed on spectral dimension to exploit the spectral information, and the posttransform (PT in 2D-DWT domain is performed on each spectral band to exploit the spatial information. A deep coupling approach between the PT and Tucker decomposition (TD is proposed to remove residual spectral redundancy between bands and residual spatial redundancy of each band. Experimental results on multispectral CCD camera data set show that the proposed compression algorithm can obtain a better compression performance and significantly outperforms the traditional compression algorithm-based TD in 2D-DWT and 3D-DCT domain.

  19. Evaluation of PeneloPET Simulations of Biograph PET/CT Scanners

    Science.gov (United States)

    Abushab, K. M.; Herraiz, J. L.; Vicente, E.; Cal-González, J.; España, S.; Vaquero, J. J.; Jakoby, B. W.; Udías, J. M.

    2016-06-01

    Monte Carlo (MC) simulations are widely used in positron emission tomography (PET) for optimizing detector design, acquisition protocols, and evaluating corrections and reconstruction methods. PeneloPET is a MC code based on PENELOPE, for PET simulations which considers detector geometry, acquisition electronics and materials, and source definitions. While PeneloPET has been successfully employed and validated with small animal PET scanners, it required a proper validation with clinical PET scanners including time-of-flight (TOF) information. For this purpose, we chose the family of Biograph PET/CT scanners: the Biograph True-Point (B-TP), Biograph True-Point with TrueV (B-TPTV) and the Biograph mCT. They have similar block detectors and electronics, but a different number of rings and configuration. Some effective parameters of the simulations, such as the dead-time and the size of the reflectors in the detectors, were adjusted to reproduce the sensitivity and noise equivalent count (NEC) rate of the B-TPTV scanner. These parameters were then used to make predictions of experimental results such as sensitivity, NEC rate, spatial resolution, and scatter fraction (SF), from all the Biograph scanners and some variations of them (energy windows and additional rings of detectors). Predictions agree with the measured values for the three scanners, within 7% (sensitivity and NEC rate) and 5% (SF). The resolution obtained for the B-TPTV is slightly better (10%) than the experimental values. In conclusion, we have shown that PeneloPET is suitable for simulating and investigating clinical systems with good accuracy and short computational time, though some effort tuning of a few parameters of the scanners modeled may be needed in case that the full details of the scanners studied are not available.

  20. Radiation dosimetry of computed tomography x-ray scanners

    International Nuclear Information System (INIS)

    Poletti, J.L.; Williamson, B.D.P.; Le Heron, J.C.

    1983-01-01

    This report describes the development and application of the methods employed in National Radiation Laboratory (NRL) surveys of computed tomography x-ray scanners (CT scanners). It includes descriptions of the phantoms and equipment used, discussion of the various dose parameters measured, the principles of the various dosimetry systems employed and some indication of the doses to occupationally exposed personnel

  1. Free-space wavelength-multiplexed optical scanner.

    Science.gov (United States)

    Yaqoob, Z; Rizvi, A A; Riza, N A

    2001-12-10

    A wavelength-multiplexed optical scanning scheme is proposed for deflecting a free-space optical beam by selection of the wavelength of the light incident on a wavelength-dispersive optical element. With fast tunable lasers or optical filters, this scanner features microsecond domain scan setting speeds and large- diameter apertures of several centimeters or more for subdegree angular scans. Analysis performed indicates an optimum scan range for a given diffraction order and grating period. Limitations include beam-spreading effects based on the varying scanner aperture sizes and the instantaneous information bandwidth of the data-carrying laser beam.

  2. Miniaturized Fourier-plane fiber scanner for OCT endoscopy

    International Nuclear Information System (INIS)

    Vilches, Sergio; Kretschmer, Simon; Ataman, Çağlar; Zappe, Hans

    2017-01-01

    A forward-looking endoscopic optical coherence tomography (OCT) probe featuring a Fourier-plane fiber scanner is designed, manufactured and characterized. In contrast to common image-plane fiber scanners, the Fourier-plane scanner is a telecentric arrangement that eliminates vignetting and spatial resolution variations across the image plane. To scan the OCT beam in a spiral pattern, a tubular piezoelectric actuator is used to resonate an optical fiber bearing a collimating GRIN lens at its tip. The free-end of the GRIN lens sits at the back focal plane of an objective lens, such that its rotation replicates the beam angles in the collimated region of a classical telecentric 4f optical system. Such an optical arrangement inherently has a low numerical aperture combined with a relatively large field-of-view, rendering it particularly useful for endoscopic OCT imaging. Furthermore, the optical train of the Fourier-plane scanner is shorter than that of a comparable image-plane scanner by one focal length of the objective lens, significantly shortening the final arrangement. As a result, enclosed within a 3D printed housing of 2.5 mm outer diameter and 15 mm total length, the developed probe is the most compact forward-looking endoscopic OCT imager to date. Due to its compact form factor and compatibility with real-time OCT imaging, the developed probe is also ideal for use in the working channel of flexible endoscopes as a potential optical biopsy tool. (paper)

  3. Miniaturized Fourier-plane fiber scanner for OCT endoscopy

    Science.gov (United States)

    Vilches, Sergio; Kretschmer, Simon; Ataman, Çağlar; Zappe, Hans

    2017-10-01

    A forward-looking endoscopic optical coherence tomography (OCT) probe featuring a Fourier-plane fiber scanner is designed, manufactured and characterized. In contrast to common image-plane fiber scanners, the Fourier-plane scanner is a telecentric arrangement that eliminates vignetting and spatial resolution variations across the image plane. To scan the OCT beam in a spiral pattern, a tubular piezoelectric actuator is used to resonate an optical fiber bearing a collimating GRIN lens at its tip. The free-end of the GRIN lens sits at the back focal plane of an objective lens, such that its rotation replicates the beam angles in the collimated region of a classical telecentric 4f optical system. Such an optical arrangement inherently has a low numerical aperture combined with a relatively large field-of-view, rendering it particularly useful for endoscopic OCT imaging. Furthermore, the optical train of the Fourier-plane scanner is shorter than that of a comparable image-plane scanner by one focal length of the objective lens, significantly shortening the final arrangement. As a result, enclosed within a 3D printed housing of 2.5 mm outer diameter and 15 mm total length, the developed probe is the most compact forward-looking endoscopic OCT imager to date. Due to its compact form factor and compatibility with real-time OCT imaging, the developed probe is also ideal for use in the working channel of flexible endoscopes as a potential optical biopsy tool.

  4. Multi Texture Analysis of Colorectal Cancer Continuum Using Multispectral Imagery.

    Directory of Open Access Journals (Sweden)

    Ahmad Chaddad

    Full Text Available This paper proposes to characterize the continuum of colorectal cancer (CRC using multiple texture features extracted from multispectral optical microscopy images. Three types of pathological tissues (PT are considered: benign hyperplasia, intraepithelial neoplasia and carcinoma.In the proposed approach, the region of interest containing PT is first extracted from multispectral images using active contour segmentation. This region is then encoded using texture features based on the Laplacian-of-Gaussian (LoG filter, discrete wavelets (DW and gray level co-occurrence matrices (GLCM. To assess the significance of textural differences between PT types, a statistical analysis based on the Kruskal-Wallis test is performed. The usefulness of texture features is then evaluated quantitatively in terms of their ability to predict PT types using various classifier models.Preliminary results show significant texture differences between PT types, for all texture features (p-value < 0.01. Individually, GLCM texture features outperform LoG and DW features in terms of PT type prediction. However, a higher performance can be achieved by combining all texture features, resulting in a mean classification accuracy of 98.92%, sensitivity of 98.12%, and specificity of 99.67%.These results demonstrate the efficiency and effectiveness of combining multiple texture features for characterizing the continuum of CRC and discriminating between pathological tissues in multispectral images.

  5. Absolute dosimetric characterization of Gafchromic EBT3 and HDv2 films using commercial flat-bed scanners and evaluation of the scanner response function variability

    Energy Technology Data Exchange (ETDEWEB)

    Chen, S. N.; Revet, G.; Fuchs, J. [LULI-CNRS, Ecole Polytechnique, CEA: Universite Paris-Saclay, UPMC Univ Paris 06, Sorbonne Universities, F-91128 Palaiseau Cedex (France); Institute of Applied Physics, 46 Ulyanov Street, 603950 Nizhny Novgorod (Russian Federation); Gauthier, M.; Glenzer, S.; Propp, A. [SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, California 94025 (United States); Bazalova-Carter, M. [Department of Physics and Astronomy, University of Victoria, Victoria, British Columbia V8P 5C2 (Canada); Bolanos, S. [LULI-CNRS, Ecole Polytechnique, CEA: Universite Paris-Saclay, UPMC Univ Paris 06, Sorbonne Universities, F-91128 Palaiseau Cedex (France); Riquier, R. [LULI-CNRS, Ecole Polytechnique, CEA: Universite Paris-Saclay, UPMC Univ Paris 06, Sorbonne Universities, F-91128 Palaiseau Cedex (France); CEA, DAM, DIF, F-91297 Arpajon (France); Antici, P. [INRS-EMT, Varennes, J3X1S2 Québec (Canada); Morabito, A. [ELI-ALPS, ELI-HU non profit kft, Dugonics ter 13, H-6720, Szeged (Hungary); Starodubtsev, M. [Institute of Applied Physics, 46 Ulyanov Street, 603950 Nizhny Novgorod (Russian Federation)

    2016-07-15

    Radiochromic films (RCF) are commonly used in dosimetry for a wide range of radiation sources (electrons, protons, and photons) for medical, industrial, and scientific applications. They are multi-layered, which includes plastic substrate layers and sensitive layers that incorporate a radiation-sensitive dye. Quantitative dose can be retrieved by digitizing the film, provided that a prior calibration exists. Here, to calibrate the newly developed EBT3 and HDv2 RCFs from Gafchromic™, we used the Stanford Medical LINAC to deposit in the films various doses of 10 MeV photons, and by scanning the films using three independent EPSON Precision 2450 scanners, three independent EPSON V750 scanners, and two independent EPSON 11000XL scanners. The films were scanned in separate RGB channels, as well as in black and white, and film orientation was varied. We found that the green channel of the RGB scan and the grayscale channel are in fact quite consistent over the different models of the scanner, although this comes at the cost of a reduction in sensitivity (by a factor ∼2.5 compared to the red channel). To allow any user to extend the absolute calibration reported here to any other scanner, we furthermore provide a calibration curve of the EPSON 2450 scanner based on absolutely calibrated, commercially available, optical density filters.

  6. Quality assessment of butter cookies applying multispectral imaging

    DEFF Research Database (Denmark)

    Stenby Andresen, Mette; Dissing, Bjørn Skovlund; Løje, Hanne

    2013-01-01

    calculated for a statistical prediction model correlating multispectral images with a browning score. The browning score is calculated as a function of oven temperature and baking time. It is presented as a quadratic response surface. The investigated process window was the intervals 4–16 min and 160–200°C...

  7. Evaluation of Handheld Scanners for Automotive Applications

    Directory of Open Access Journals (Sweden)

    Wadea Ameen

    2018-01-01

    Full Text Available The process of generating a computerized geometric model for an existing part is known as Reverse Engineering (RE. It is a very useful technique in product development and plays a significant role in automotive, aerospace, and medical industries. In fact, it has been getting remarkable attention in manufacturing industries owing to its advanced data acquisition technologies. The process of RE is based on two primary steps: data acquisition (also known as scanning and data processing. To facilitate point data acquisition, a variety of scanning systems is available with different capabilities and limitations. Although the optical control of 3D scanners is fully developed, still several factors can affect the quality of the scanned data. As a result, the proper selection of scanning parameters, such as resolution, laser power, shutter time, etc., becomes very crucial. This kind of investigation can be very helpful and provide its users with guidelines to identify the appropriate factors. Moreover, it is worth noting that no single system is ideal in all applications. Accordingly, this work has compared two portable (handheld systems based on laser scanning and white light optical scanning for automotive applications. A car door containing a free-form surface has been used to achieve the above-mentioned goal. The design of experiments has been employed to determine the effects of different scanning parameters and optimize them. The capabilities and limitations have been identified by comparing the two scanners in terms of accuracy, scanning time, triangle numbers, ease of use, and portability. Then, the relationships between the system capabilities and the application requirements have been established. The results revealed that the laser scanner performed better than the white light scanner in terms of accuracy, while the white light scanner performed better in terms of acquisition speed and triangle numbers.

  8. [Practicability of the mobile one-finger scanner Cross Match MV5 in fingerprinting of corpses: are mobile fingerprinting scanners suitable for use in mass disasters?].

    Science.gov (United States)

    Breitmeier, Dirk; Landmesser, Britta; Schulz, Yvonne; Albrecht, Knut

    2008-01-01

    Dactyloscopy is a special field in the police records department and a suitable means for identifying unknown dead persons as well as solving crimes by taking fingerprints from living persons. Apart from the conventional methods of dactyloscopy, mobile and more compact instruments are to facilitate taking prints of fingertips and palms also at the scene of mass disasters. In the presented study, living persons and corpses were examined to find out the possible uses and limits of mobile one-finger scanners. The concrete issue of the investigation was whether the mobile one-finger scanner Cross Match MV5 is suitable for application in mass disasters. The device was used in 12 corpses aged 5 weeks to 76 years (mean postmortem interval 5.5 days) and in 28 living persons aged 6 weeks to 87 years. In summary, the scanner produced qualitatively good prints in all age groups of the living individuals. In the corpses, the prints were only partly evaluable. In particular, fingers and fingertips with soot blackening and livid discoloration were difficult to analyse. Postmortem rigidity also complicated the handling of the scanner. In fresh corpses, the scanner can be recommended without reservation. Even if the epidermis was detached, the scanner was able to produce evaluable prints of the dermis of the hypothenar.

  9. Acquisition performance of LAPAN-A3/IPB multispectral imager in real-time mode of operation

    Science.gov (United States)

    Hakim, P. R.; Permala, R.; Jayani, A. P. S.

    2018-05-01

    LAPAN-A3/IPB satellite was launched in June 2016 and its multispectral imager has been producing Indonesian coverage images. In order to improve its support for remote sensing application, the imager should produce images with high quality and quantity. To improve the quantity of LAPAN-A3/IPB multispectral image captured, image acquisition could be executed in real-time mode from LAPAN ground station in Bogor when the satellite passes west Indonesia region. This research analyses the performance of LAPAN-A3/IPB multispectral imager acquisition in real-time mode, in terms of image quality and quantity, under assumption of several on-board and ground segment limitations. Results show that with real-time operation mode, LAPAN-A3/IPB multispectral imager could produce twice as much as image coverage compare to recorded mode. However, the images produced in real-time mode will have slightly degraded quality due to image compression process involved. Based on several analyses that have been done in this research, it is recommended to use real-time acquisition mode whenever it possible, unless for some circumstances that strictly not allow any quality degradation of the images produced.

  10. Multispectral medical image fusion in Contourlet domain for computer based diagnosis of Alzheimer’s disease

    International Nuclear Information System (INIS)

    Bhateja, Vikrant; Moin, Aisha; Srivastava, Anuja; Bao, Le Nguyen; Lay-Ekuakille, Aimé; Le, Dac-Nhuong

    2016-01-01

    Computer based diagnosis of Alzheimer’s disease can be performed by dint of the analysis of the functional and structural changes in the brain. Multispectral image fusion deliberates upon fusion of the complementary information while discarding the surplus information to achieve a solitary image which encloses both spatial and spectral details. This paper presents a Non-Sub-sampled Contourlet Transform (NSCT) based multispectral image fusion model for computer-aided diagnosis of Alzheimer’s disease. The proposed fusion methodology involves color transformation of the input multispectral image. The multispectral image in YIQ color space is decomposed using NSCT followed by dimensionality reduction using modified Principal Component Analysis algorithm on the low frequency coefficients. Further, the high frequency coefficients are enhanced using non-linear enhancement function. Two different fusion rules are then applied to the low-pass and high-pass sub-bands: Phase congruency is applied to low frequency coefficients and a combination of directive contrast and normalized Shannon entropy is applied to high frequency coefficients. The superiority of the fusion response is depicted by the comparisons made with the other state-of-the-art fusion approaches (in terms of various fusion metrics).

  11. Multispectral medical image fusion in Contourlet domain for computer based diagnosis of Alzheimer’s disease

    Energy Technology Data Exchange (ETDEWEB)

    Bhateja, Vikrant, E-mail: bhateja.vikrant@gmail.com, E-mail: nhuongld@hus.edu.vn; Moin, Aisha; Srivastava, Anuja [Shri Ramswaroop Memorial Group of Professional Colleges (SRMGPC), Lucknow, Uttar Pradesh 226028 (India); Bao, Le Nguyen [Duytan University, Danang 550000 (Viet Nam); Lay-Ekuakille, Aimé [Department of Innovation Engineering, University of Salento, Lecce 73100 (Italy); Le, Dac-Nhuong, E-mail: bhateja.vikrant@gmail.com, E-mail: nhuongld@hus.edu.vn [Duytan University, Danang 550000 (Viet Nam); Haiphong University, Haiphong 180000 (Viet Nam)

    2016-07-15

    Computer based diagnosis of Alzheimer’s disease can be performed by dint of the analysis of the functional and structural changes in the brain. Multispectral image fusion deliberates upon fusion of the complementary information while discarding the surplus information to achieve a solitary image which encloses both spatial and spectral details. This paper presents a Non-Sub-sampled Contourlet Transform (NSCT) based multispectral image fusion model for computer-aided diagnosis of Alzheimer’s disease. The proposed fusion methodology involves color transformation of the input multispectral image. The multispectral image in YIQ color space is decomposed using NSCT followed by dimensionality reduction using modified Principal Component Analysis algorithm on the low frequency coefficients. Further, the high frequency coefficients are enhanced using non-linear enhancement function. Two different fusion rules are then applied to the low-pass and high-pass sub-bands: Phase congruency is applied to low frequency coefficients and a combination of directive contrast and normalized Shannon entropy is applied to high frequency coefficients. The superiority of the fusion response is depicted by the comparisons made with the other state-of-the-art fusion approaches (in terms of various fusion metrics).

  12. Portable multispectral imaging system for oral cancer diagnosis

    Science.gov (United States)

    Hsieh, Yao-Fang; Ou-Yang, Mang; Lee, Cheng-Chung

    2013-09-01

    This study presents the portable multispectral imaging system that can acquire the image of specific spectrum in vivo for oral cancer diagnosis. According to the research literature, the autofluorescence of cells and tissue have been widely applied to diagnose oral cancer. The spectral distribution is difference for lesions of epithelial cells and normal cells after excited fluorescence. We have been developed the hyperspectral and multispectral techniques for oral cancer diagnosis in three generations. This research is the third generation. The excited and emission spectrum for the diagnosis are acquired from the research of first generation. The portable system for detection of oral cancer is modified for existing handheld microscope. The UV LED is used to illuminate the surface of oral cavity and excite the cells to produce fluorescent. The image passes through the central channel and filters out unwanted spectrum by the selection of filter, and focused by the focus lens on the image sensor. Therefore, we can achieve the specific wavelength image via fluorescence reaction. The specificity and sensitivity of the system are 85% and 90%, respectively.

  13. Monte Carlo simulation of efficient data acquisition for an entire-body PET scanner

    Energy Technology Data Exchange (ETDEWEB)

    Isnaini, Ismet; Obi, Takashi [Tokyo Institute of Technology, 4259 Nagatsuta-cho, Midori-ku, Yokohama 226-8503 (Japan); Yoshida, Eiji, E-mail: rush@nirs.go.jp [National Institute of Radiological Sciences, 4-9-1 Inage-ku, Chiba 263-8555 (Japan); Yamaya, Taiga [National Institute of Radiological Sciences, 4-9-1 Inage-ku, Chiba 263-8555 (Japan)

    2014-07-01

    Conventional PET scanners can image the whole body using many bed positions. On the other hand, an entire-body PET scanner with an extended axial FOV, which can trace whole-body uptake images at the same time and improve sensitivity dynamically, has been desired. The entire-body PET scanner would have to process a large amount of data effectively. As a result, the entire-body PET scanner has high dead time at a multiplex detector grouping process. Also, the entire-body PET scanner has many oblique line-of-responses. In this work, we study an efficient data acquisition for the entire-body PET scanner using the Monte Carlo simulation. The simulated entire-body PET scanner based on depth-of-interaction detectors has a 2016-mm axial field-of-view (FOV) and an 80-cm ring diameter. Since the entire-body PET scanner has higher single data loss than a conventional PET scanner at grouping circuits, the NECR of the entire-body PET scanner decreases. But, single data loss is mitigated by separating the axially arranged detector into multiple parts. Our choice of 3 groups of axially-arranged detectors has shown to increase the peak NECR by 41%. An appropriate choice of maximum ring difference (MRD) will also maintain the same high performance of sensitivity and high peak NECR while at the same time reduces the data size. The extremely-oblique line of response for large axial FOV does not contribute much to the performance of the scanner. The total sensitivity with full MRD increased only 15% than that with about half MRD. The peak NECR was saturated at about half MRD. The entire-body PET scanner promises to provide a large axial FOV and to have sufficient performance values without using the full data.

  14. Moths on the Flatbed Scanner: The Art of Joseph Scheer

    Directory of Open Access Journals (Sweden)

    Stephen L. Buchmann

    2011-12-01

    Full Text Available During the past decade a few artists and even fewer entomologists discovered flatbed scanning technology, using extreme resolution graphical arts scanners for acquiring high magnification digital images of plants, animals and inanimate objects. They are not just for trip receipts anymore. The special attributes of certain scanners, to image thick objects is discussed along with the technical features of the scanners including magnification, color depth and shadow detail. The work of pioneering scanner artist, Joseph Scheer from New York’s Alfred University is highlighted. Representative flatbed-scanned images of moths are illustrated along with techniques to produce them. Collecting and preparing moths, and other objects, for scanning are described. Highlights of the Fulbright sabbatical year of professor Scheer in Arizona and Sonora, Mexico are presented, along with comments on moths in science, folklore, art and pop culture. The use of flatbed scanners is offered as a relatively new method for visualizing small objects while acquiring large files for creating archival inkjet prints for display and sale.

  15. High performance multi-spectral interrogation for surface plasmon resonance imaging sensors.

    Science.gov (United States)

    Sereda, A; Moreau, J; Canva, M; Maillart, E

    2014-04-15

    Surface plasmon resonance (SPR) sensing has proven to be a valuable tool in the field of surface interactions characterization, especially for biomedical applications where label-free techniques are of particular interest. In order to approach the theoretical resolution limit, most SPR-based systems have turned to either angular or spectral interrogation modes, which both offer very accurate real-time measurements, but at the expense of the 2-dimensional imaging capability, therefore decreasing the data throughput. In this article, we show numerically and experimentally how to combine the multi-spectral interrogation technique with 2D-imaging, while finding an optimum in terms of resolution, accuracy, acquisition speed and reduction in data dispersion with respect to the classical reflectivity interrogation mode. This multi-spectral interrogation methodology is based on a robust five parameter fitting of the spectral reflectivity curve which enables monitoring of the reflectivity spectral shift with a resolution of the order of ten picometers, and using only five wavelength measurements per point. In fine, such multi-spectral based plasmonic imaging system allows biomolecular interaction monitoring in a linear regime independently of variations of buffer optical index, which is illustrated on a DNA-DNA model case. © 2013 Elsevier B.V. All rights reserved.

  16. Scanner-based macroscopic color variation estimation

    Science.gov (United States)

    Kuo, Chunghui; Lai, Di; Zeise, Eric

    2006-01-01

    Flatbed scanners have been adopted successfully in the measurement of microscopic image artifacts, such as granularity and mottle, in print samples because of their capability of providing full color, high resolution images. Accurate macroscopic color measurement relies on the use of colorimeters or spectrophotometers to provide a surrogate for human vision. The very different color response characteristics of flatbed scanners from any standard colorimetric response limits the utility of a flatbed scanner as a macroscopic color measuring device. This metamerism constraint can be significantly relaxed if our objective is mainly to quantify the color variations within a printed page or between pages where a small bias in measured colors can be tolerated as long as the color distributions relative to the individual mean values is similar. Two scenarios when converting color from the device RGB color space to a standardized color space such as CIELab are studied in this paper, blind and semi-blind color transformation, depending on the availability of the black channel information. We will show that both approaches offer satisfactory results in quantifying macroscopic color variation across pages while the semi-blind color transformation further provides fairly accurate color prediction capability.

  17. Impedance Characterisation of the SPS Wire Scanner

    CERN Document Server

    AUTHOR|(CDS)2091911; Prof. Sillanpää, Mika

    As a beam diagnostic tool, the SPS wire scanner interacts with the proton bunches traversing the vacuum pipes of the Super Proton Synchrotron particle accelerator. Following the interaction, the bunches decelerate or experience momentum kicks off-axis and couple energy to the cavity walls, resonances and to the diagnostic tool, the scanning wire. The beam coupling impedance and, in particular, the beam induced heating of the wire motivate the characterisation and redesign of the SPS wire scanner. In this thesis, we characterise RF-wise the low frequency modes of the SPS wire scanner. These have the highest contribution to the impedance. We measure the cavity modes in terms of resonance frequency and quality factor by traditional measurement techniques and data analysis. We carry out a 4-port measurement to evaluate the beam coupling to the scanning wire, that yields the spectral heating power. If combined with the simulations, one is able to extract the beam coupling impedance and deduce the spectral dissipa...

  18. A scanner for single photon emission tomography

    International Nuclear Information System (INIS)

    Smith, D.B.; Cumpstey, D.E.; Evans, N.T.S.; Coleman, J.D.; Ettinger, K.V.; Mallard, J.R.

    1982-01-01

    The technique of single photon ECT has now been available for some eighteen years, but has yet still to be exploited fully. The difficulties of doing this lie in the need for gathering data of sufficiently good statistical accuracy in a reasonable counting time, in the uniformity of detector sensitivity, and in the means for correcting the image satisfactorily for photon attenuation within the body. The relative ease with which a general purpose gamma camera can be adapted to give rotation around the patient makes this an attractive practical approach to the problem. However, the sensitivity of gamma cameras over their field of view is by no means uniform, and their sensitivity is less good than that of purpose-designed scanners when no more than about ten sections through the body are required. There is therefore a need to assess the clinical usefulness of a whole body tomographic scanner of high sensitivity and uniformity. Such a machine is the Aberdeen Section Scanner Mark II described

  19. Geometric calibration between PET scanner and structured light scanner

    DEFF Research Database (Denmark)

    Kjer, Hans Martin; Olesen, Oline Vinter; Paulsen, Rasmus Reinhold

    2011-01-01

    Head movements degrade the image quality of high resolution Positron Emission Tomography (PET) brain studies through blurring and artifacts. Manny image reconstruction methods allows for motion correction if the head position is tracked continuously during the study. Our method for motion tracking...... is a structured light scanner placed just above the patient tunnel on the High Resolution Research Tomograph (HRRT, Siemens). It continuously registers point clouds of a part of the patient's face. The relative motion is estimated as the rigid transformation between frames. A geometric calibration between...

  20. Method for calibration of an axial tomographic scanner

    International Nuclear Information System (INIS)

    Sparks, R.A.

    1977-01-01

    The method of calibrating an axial tomographic scanner including frame means having an opening therein in which an object to be examined is to be placed, source and detector means mounted on the frame means for directing one or more beams of penetrating radiation through the object from the source to the detector means, and means to rotate the scanner including the source and detector means about the object whereby a plurality of sets of data corresponding to the transmission or absorption by the object of a plurality of beams of penetrating radiation are collected; the calibration method comprising mounting calibration means supporting an adjustable centering member onto the frame means, positioning the adjustable centering member at approximately the center of rotation of the scanner, placing position-sensitive indicator means adjacent the approximately centered member, rotating the scanner and the calibration means mounted thereon at least one time and, if necessary, adjusting the positioning of the centering member until the centering member is coincident with the center of rotation of the scanner as determined by minimum deflection of the position-sensitive indicator means, rotating and translating the source and detector means and determining for each angular orientation of the frame means supporting the source and detector means the central position of each translational scan relative to the centered member and/or if a plurality of detectors are utilized with the detector means for each planar slice of the object being examined, the central position of each translational scan for each detector relative to the centered member

  1. Vicarious Radiometric Calibration of a Multispectral Camera on Board an Unmanned Aerial System

    Directory of Open Access Journals (Sweden)

    Susana Del Pozo

    2014-02-01

    Full Text Available Combinations of unmanned aerial platforms and multispectral sensors are considered low-cost tools for detailed spatial and temporal studies addressing spectral signatures, opening a broad range of applications in remote sensing. Thus, a key step in this process is knowledge of multi-spectral sensor calibration parameters in order to identify the physical variables collected by the sensor. This paper discusses the radiometric calibration process by means of a vicarious method applied to a high-spatial resolution unmanned flight using low-cost artificial and natural covers as control and check surfaces, respectively.

  2. Performance of an improved first generation optical CT scanner for 3D dosimetry

    International Nuclear Information System (INIS)

    Qian, Xin; Wuu, Cheng-Shie; Adamovics, John

    2013-01-01

    Performance analysis of a modified 3D dosimetry optical scanner based on the first generation optical CT scanner OCTOPUS is presented. The system consists of PRESAGE™ dosimeters, the modified 3D scanner, and a new developed in-house user control panel written in Labview program which provides more flexibility to optimize mechanical control and data acquisition technique. The total scanning time has been significantly reduced from initial 8 h to ∼2 h by using the modified scanner. The functional performance of the modified scanner has been evaluated in terms of the mechanical integrity uncertainty of the data acquisition process. Optical density distribution comparison between the modified scanner, OCTOPUS and the treatment plan system has been studied. It has been demonstrated that the agreement between the modified scanner and treatment plans is comparable with that between the OCTOPUS and treatment plans. (note)

  3. A virtual seed file: the use of multispectral image analysis in the management of genebank seed accessions

    DEFF Research Database (Denmark)

    Adsetts Edberg Hansen, Michael; R. Hay, Fiona; Carstensen, Jens Michael

    2015-01-01

    We present a method for multispectral seed phenotyping as a fast and robust tool for managing genebank accessions. A multispectral vision system was used to take images of the seeds of 20 diverse varieties of rice (approximately 30 seeds for each variety). This was followed by extraction of feature...

  4. Accuracy of automated volumetry of pulmonary nodules across different multislice CT scanners

    International Nuclear Information System (INIS)

    Das, Marco; Muehlenbruch, Georg; Mahnken, Andreas H.; Katoh, Markus; Guenther, Rolf W.; Wildberger, Joachim E.; Ley-Zaporozhan, Julia; Kauczor, Hans-Ulrich; Gietema, H.A.; Prokop, Mathias; Czech, Andre; Diederich, Stefan; Bakai, Annemarie; Salganicoff, Marcos

    2007-01-01

    The purpose of this study was to compare the accuracy of an automated volumetry software for phantom pulmonary nodules across various 16-slice multislice spiral CT (MSCT) scanners from different vendors. A lung phantom containing five different nodule categories (intraparenchymal, around a vessel, vessel attached, pleural, and attached to the pleura), with each category comprised of 7-9 nodules (total, n = 40) of varying sizes (diameter 3-10 mm; volume 6.62 mm 3 -525 mm 3 ), was scanned with four different 16-slice MSCT scanners (Siemens, GE, Philips, Toshiba). Routine and low-dose chest protocols with thin and thick collimations were applied. The data from all scanners were used for further analysis using a dedicated prototype volumetry software. Absolute percentage volume errors (APE) were calculated and compared. The mean APE for all nodules was 8.4% (±7.7%) for data acquired with the 16-slice Siemens scanner, 14.3% (±11.1%) for the GE scanner, 9.7% (±9.6%) for the Philips scanner and 7.5% (±7.2%) for the Toshiba scanner, respectively. The lowest APEs were found within the diameter size range of 5-10 mm and volumes >66 mm 3 . Nodule volumetry is accurate with a reasonable volume error in data from different scanner vendors. This may have an important impact for intraindividual follow-up studies. (orig.)

  5. Adaptive Residual Interpolation for Color and Multispectral Image Demosaicking.

    Science.gov (United States)

    Monno, Yusuke; Kiku, Daisuke; Tanaka, Masayuki; Okutomi, Masatoshi

    2017-12-01

    Color image demosaicking for the Bayer color filter array is an essential image processing operation for acquiring high-quality color images. Recently, residual interpolation (RI)-based algorithms have demonstrated superior demosaicking performance over conventional color difference interpolation-based algorithms. In this paper, we propose adaptive residual interpolation (ARI) that improves existing RI-based algorithms by adaptively combining two RI-based algorithms and selecting a suitable iteration number at each pixel. These are performed based on a unified criterion that evaluates the validity of an RI-based algorithm. Experimental comparisons using standard color image datasets demonstrate that ARI can improve existing RI-based algorithms by more than 0.6 dB in the color peak signal-to-noise ratio and can outperform state-of-the-art algorithms based on training images. We further extend ARI for a multispectral filter array, in which more than three spectral bands are arrayed, and demonstrate that ARI can achieve state-of-the-art performance also for the task of multispectral image demosaicking.

  6. Hyperspectral and multispectral data fusion based on linear-quadratic nonnegative matrix factorization

    Science.gov (United States)

    Benhalouche, Fatima Zohra; Karoui, Moussa Sofiane; Deville, Yannick; Ouamri, Abdelaziz

    2017-04-01

    This paper proposes three multisharpening approaches to enhance the spatial resolution of urban hyperspectral remote sensing images. These approaches, related to linear-quadratic spectral unmixing techniques, use a linear-quadratic nonnegative matrix factorization (NMF) multiplicative algorithm. These methods begin by unmixing the observable high-spectral/low-spatial resolution hyperspectral and high-spatial/low-spectral resolution multispectral images. The obtained high-spectral/high-spatial resolution features are then recombined, according to the linear-quadratic mixing model, to obtain an unobservable multisharpened high-spectral/high-spatial resolution hyperspectral image. In the first designed approach, hyperspectral and multispectral variables are independently optimized, once they have been coherently initialized. These variables are alternately updated in the second designed approach. In the third approach, the considered hyperspectral and multispectral variables are jointly updated. Experiments, using synthetic and real data, are conducted to assess the efficiency, in spatial and spectral domains, of the designed approaches and of linear NMF-based approaches from the literature. Experimental results show that the designed methods globally yield very satisfactory spectral and spatial fidelities for the multisharpened hyperspectral data. They also prove that these methods significantly outperform the used literature approaches.

  7. Application of multispectral imaging to determine quality attributes and ripeness stage in strawberry fruit.

    Directory of Open Access Journals (Sweden)

    Changhong Liu

    Full Text Available Multispectral imaging with 19 wavelengths in the range of 405-970 nm has been evaluated for nondestructive determination of firmness, total soluble solids (TSS content and ripeness stage in strawberry fruit. Several analysis approaches, including partial least squares (PLS, support vector machine (SVM and back propagation neural network (BPNN, were applied to develop theoretical models for predicting the firmness and TSS of intact strawberry fruit. Compared with PLS and SVM, BPNN considerably improved the performance of multispectral imaging for predicting firmness and total soluble solids content with the correlation coefficient (r of 0.94 and 0.83, SEP of 0.375 and 0.573, and bias of 0.035 and 0.056, respectively. Subsequently, the ability of multispectral imaging technology to classify fruit based on ripeness stage was tested using SVM and principal component analysis-back propagation neural network (PCA-BPNN models. The higher classification accuracy of 100% was achieved using SVM model. Moreover, the results of all these models demonstrated that the VIS parts of the spectra were the main contributor to the determination of firmness, TSS content estimation and classification of ripeness stage in strawberry fruit. These results suggest that multispectral imaging, together with suitable analysis model, is a promising technology for rapid estimation of quality attributes and classification of ripeness stage in strawberry fruit.

  8. Remote Sensing of Smoke, Land and Clouds from the NASA ER-2 during SAFARI 2000

    Science.gov (United States)

    King, Michael D.; Platnick, Steven; Moeller, Christopher C.; Revercomb, Henry E.; Chu, D. Allen

    2002-01-01

    The NASA ER-2 aircraft was deployed to southern Africa between August 17 and September 25, 2000 as part of the Southern Africa Regional Science Initiative (SAFARI) 2000. This aircraft carried a sophisticated array of multispectral scanners, multiangle spectroradiometers, a monostatic lidar, a gas correlation radiometer, upward and downward spectral flux radiometers, and two metric mapping cameras. These observations were obtained over a 3200 x 2800 km region of savanna, woody savanna, open shrubland, and grassland ecosystems throughout southern Africa, and were quite often coordinated with overflights by NASA's Terra and Landsat 7 satellites. The primary purpose of this sophisticated high altitude observing platform was to obtain independent observations of smoke, clouds, and land surfaces that could be used to check the validity of various remote sensing measurements derived by Earth-orbiting satellites. These include such things as the accuracy of the Moderate Resolution Imaging Spectro-radiometer (MODIS) cloud mask for distinguishing clouds and heavy aerosol from land and ocean surfaces, and Terra analyses of cloud optical and micro-physical properties, aerosol properties, leaf area index, vegetation index, fire occurrence, carbon monoxide, and surface radiation budget. In addition to coordination with Terra and Landsat 7 satellites, numerous flights were conducted over surface AERONET sites, flux towers in South Africa, Botswana, and Zambia, and in situ aircraft from the University of Washington, South Africa, and the United Kingdom.

  9. High Spatial Resolution Airborne Multispectral Thermal Infrared Remote Sensing Data for Analysis of Urban Landscape Characteristics

    Science.gov (United States)

    Quattrochi, Dale A.; Luvall, Jeffrey C.; Estes, Maurice G., Jr.; Arnold, James E. (Technical Monitor)

    2000-01-01

    We have used airborne multispectral thermal infrared (TIR) remote sensing data collected at a high spatial resolution (i.e., 10m) over several cities in the United States to study thermal energy characteristics of the urban landscape. These TIR data provide a unique opportunity to quantify thermal responses from discrete surfaces typical of the urban landscape and to identify both the spatial arrangement and patterns of thermal processes across the city. The information obtained from these data is critical to understanding how urban surfaces drive or force development of the Urban Heat Island (UHI) effect, which exists as a dome of elevated air temperatures that presides over cities in contrast to surrounding non-urbanized areas. The UHI is most pronounced in the summertime where urban surfaces, such as rooftops and pavement, store solar radiation throughout the day, and release this stored energy slowly after sunset creating air temperatures over the city that are in excess of 2-4'C warmer in contrast with non-urban or rural air temperatures. The UHI can also exist as a daytime phenomenon with surface temperatures in downtown areas of cities exceeding 38'C. The implications of the UHI are significant, particularly as an additive source of thermal energy input that exacerbates the overall production of ground level ozone over cities. We have used the Airborne Thermal and Land Applications Sensor (ATLAS), flown onboard a Lear 23 jet aircraft from the NASA Stennis Space Center, to acquire high spatial resolution multispectral TIR data (i.e., 6 bandwidths between 8.2-12.2 (um) over Huntsville, Alabama, Atlanta, Georgia, Baton Rouge, Louisiana, Salt Lake City, Utah, and Sacramento, California. These TIR data have been used to produce maps and other products, showing the spatial distribution of heating and cooling patterns over these cities to better understand how the morphology of the urban landscape affects development of the UHI. In turn, these data have been used

  10. Efficient system modeling for a small animal PET scanner with tapered DOI detectors

    International Nuclear Information System (INIS)

    Zhang, Mengxi; Zhou, Jian; Yang, Yongfeng; Qi, Jinyi; Rodríguez-Villafuerte, Mercedes

    2016-01-01

    A prototype small animal positron emission tomography (PET) scanner for mouse brain imaging has been developed at UC Davis. The new scanner uses tapered detector arrays with depth of interaction (DOI) measurement. In this paper, we present an efficient system model for the tapered PET scanner using matrix factorization and a virtual scanner geometry. The factored system matrix mainly consists of two components: a sinogram blurring matrix and a geometrical matrix. The geometric matrix is based on a virtual scanner geometry. The sinogram blurring matrix is estimated by matrix factorization. We investigate the performance of different virtual scanner geometries. Both simulation study and real data experiments are performed in the fully 3D mode to study the image quality under different system models. The results indicate that the proposed matrix factorization can maintain image quality while substantially reduce the image reconstruction time and system matrix storage cost. The proposed method can be also applied to other PET scanners with DOI measurement. (paper)

  11. An evaluation of simulated Thematic Mapper data and Landsat MSS data for discriminating suburban and regional land use and land cover

    Science.gov (United States)

    Toll, D. L.

    1984-01-01

    An airborne multispectral scanner, operating in the same spectral channels as the Landsat Thematic Mapper (TM), was used in a region east of Denver, CO, for a simulation test performed in the framework of using TM to discriminate the level I and level II classes. It is noted that at the 30-m spatial resolution of the Thematic Mapper Simulator (TMS) the overall discrimination for such classes as commercial/industrial land, rangeland, irrigated sod, irrigated alfalfa, and irrigated pasture was superior to that of the Landsat Multispectral Scanner, primarily due to four added spectral bands. For residential and other spectrally heterogeneous classes, however, the higher resolution of TMS resulted in increased variability within the class and a larger spectral overlap.

  12. Characterization of a Large, Low-Cost 3D Scanner

    Directory of Open Access Journals (Sweden)

    Jeremy Straub

    2015-01-01

    Full Text Available Imagery-based 3D scanning can be performed by scanners with multiple form factors, ranging from small and inexpensive scanners requiring manual movement around a stationary object to large freestanding (nearly instantaneous units. Small mobile units are problematic for use in scanning living creatures, which may be unwilling or unable to (or for the very young and animals, unaware of the need to hold a fixed position for an extended period of time. Alternately, very high cost scanners that can capture a complete scan within a few seconds are available, but they are cost prohibitive for some applications. This paper seeks to assess the performance of a large, low-cost 3D scanner, presented in prior work, which is able to concurrently capture imagery from all around an object. It provides the capabilities of the large, freestanding units at a price point akin to the smaller, mobile ones. This allows access to 3D scanning technology (particularly for applications requiring instantaneous imaging at a lower cost. Problematically, prior analysis of the scanner’s performance was extremely limited. This paper characterizes the efficacy of the scanner for scanning both inanimate objects and humans. Given the importance of lighting to visible light scanning systems, the scanner’s performance under multiple lighting configurations is evaluated, characterizing its sensitivity to lighting design.

  13. A near-infrared confocal scanner

    International Nuclear Information System (INIS)

    Lee, Seungwoo; Yoo, Hongki

    2014-01-01

    In the semiconductor industry, manufacturing of three-dimensional (3D) packages or 3D integrated circuits is a high-performance technique that requires combining several functions in a small volume. Through-silicon vias, which are vertical electrical connections extending through a wafer, can be used to direct signals between stacked chips, thus increasing areal density by stacking and connecting multiple patterned chips. While defect detection is essential in the semiconductor manufacturing process, it is difficult to identify defects within a wafer or to monitor the bonding results between bonded surfaces because silicon and many other semiconductor materials are opaque to visible wavelengths. In this context, near-infrared (NIR) imaging is a promising non-destructive method to detect defects within silicon chips, to inspect bonding between chips and to monitor the chip alignment since NIR transmits through silicon. In addition, a confocal scanner provides high-contrast, optically-sectioned images of the specimen due to its ability to reject out-of-focus noise. In this study, we report an NIR confocal scanner that rapidly acquires high-resolution images with a large field of view through silicon. Two orthogonal line-scanning images can be acquired without rotating the system or the specimen by utilizing two orthogonally configured resonant scanning mirrors. This NIR confocal scanner can be efficiently used as an in-line inspection system when manufacturing semiconductor devices by rapidly detecting defects on and beneath the surface. (paper)

  14. Automated oil spill detection with multispectral imagery

    Science.gov (United States)

    Bradford, Brian N.; Sanchez-Reyes, Pedro J.

    2011-06-01

    In this publication we present an automated detection method for ocean surface oil, like that which existed in the Gulf of Mexico as a result of the April 20, 2010 Deepwater Horizon drilling rig explosion. Regions of surface oil in airborne imagery are isolated using red, green, and blue bands from multispectral data sets. The oil shape isolation procedure involves a series of image processing functions to draw out the visual phenomenological features of the surface oil. These functions include selective color band combinations, contrast enhancement and histogram warping. An image segmentation process then separates out contiguous regions of oil to provide a raster mask to an analyst. We automate the detection algorithm to allow large volumes of data to be processed in a short time period, which can provide timely oil coverage statistics to response crews. Geo-referenced and mosaicked data sets enable the largest identified oil regions to be mapped to exact geographic coordinates. In our simulation, multispectral imagery came from multiple sources including first-hand data collected from the Gulf. Results of the simulation show the oil spill coverage area as a raster mask, along with histogram statistics of the oil pixels. A rough square footage estimate of the coverage is reported if the image ground sample distance is available.

  15. Use of Terrestrial Laser Scanner for Rigid Airport Pavement Management

    Directory of Open Access Journals (Sweden)

    Maurizio Barbarella

    2017-12-01

    Full Text Available The evaluation of the structural efficiency of airport infrastructures is a complex task. Faulting is one of the most important indicators of rigid pavement performance. The aim of our study is to provide a new method for faulting detection and computation on jointed concrete pavements. Nowadays, the assessment of faulting is performed with the use of laborious and time-consuming measurements that strongly hinder aircraft traffic. We proposed a field procedure for Terrestrial Laser Scanner data acquisition and a computation flow chart in order to identify and quantify the fault size at each joint of apron slabs. The total point cloud has been used to compute the least square plane fitting those points. The best-fit plane for each slab has been computed too. The attitude of each slab plane with respect to both the adjacent ones and the apron reference plane has been determined by the normal vectors to the surfaces. Faulting has been evaluated as the difference in elevation between the slab planes along chosen sections. For a more accurate evaluation of the faulting value, we have then considered a few strips of data covering rectangular areas of different sizes across the joints. The accuracy of the estimated quantities has been computed too.

  16. Use of Terrestrial Laser Scanner for Rigid Airport Pavement Management.

    Science.gov (United States)

    Barbarella, Maurizio; D'Amico, Fabrizio; De Blasiis, Maria Rosaria; Di Benedetto, Alessandro; Fiani, Margherita

    2017-12-26

    The evaluation of the structural efficiency of airport infrastructures is a complex task. Faulting is one of the most important indicators of rigid pavement performance. The aim of our study is to provide a new method for faulting detection and computation on jointed concrete pavements. Nowadays, the assessment of faulting is performed with the use of laborious and time-consuming measurements that strongly hinder aircraft traffic. We proposed a field procedure for Terrestrial Laser Scanner data acquisition and a computation flow chart in order to identify and quantify the fault size at each joint of apron slabs. The total point cloud has been used to compute the least square plane fitting those points. The best-fit plane for each slab has been computed too. The attitude of each slab plane with respect to both the adjacent ones and the apron reference plane has been determined by the normal vectors to the surfaces. Faulting has been evaluated as the difference in elevation between the slab planes along chosen sections. For a more accurate evaluation of the faulting value, we have then considered a few strips of data covering rectangular areas of different sizes across the joints. The accuracy of the estimated quantities has been computed too.

  17. Use of multispectral images and chemometrics in tomato seed studies

    DEFF Research Database (Denmark)

    Shrestha, Santosh; Deleuran, Lise Christina; Gislum, René

    During the production of tomato seeds, green tomatoes are normally discarded before seed extraction irrespective of their maturity stage. Studies indicate that seeds from green tomatoes may reach be able to reach full germination capacity. Thus the potential of multispectral imaging for non......-destructive discrimination of seeds based on their germination capacity was investigated. A total of 840 seeds extracted from green and red tomatoes were divided into two sets; a training set and a test set consisting of 648 and 192 seeds respectively. Each set consisted of 96 seeds from green tomatoes. The multispectral...... images of the seeds were captured and normalized canonical discriminant analysis was used to analyse the images. Germination tests were performed and seeds that subsequently germinated were recorded as viable. The viable seeds were classified with 99% and 98% accuracy for the training and test set...

  18. A Direct and Fast Methodology for Ship Recognition in Sentinel-2 Multispectral Imagery

    Directory of Open Access Journals (Sweden)

    Henning Heiselberg

    2016-12-01

    Full Text Available The European Space Agency satellite Sentinel-2 provides multispectral images with pixel sizes down to 10 m. This high resolution allows for ship detection and recognition by determining a number of important ship parameters. We are able to show how a ship position, its heading, length and breadth can be determined down to a subpixel resolution. If the ship is moving, its velocity can also be determined from its Kelvin waves. The 13 spectrally different visual and infrared images taken using multispectral imagery (MSI are “fingerprints” that allow for the recognition and identification of ships. Furthermore, the multispectral image profiles along the ship allow for discrimination between the ship, its turbulent wakes, and the Kelvin waves, such that the ship’s length and breadth can be determined more accurately even when sailing. The ship’s parameters are determined by using satellite imagery taken from several ships, which are then compared to known values from the automatic identification system. The agreement is on the order of the pixel resolution or better.

  19. The performance characteristics of the Philips Gemini PET/CT scanner

    International Nuclear Information System (INIS)

    O'Keefe, G.J.; Papenfuss, A.T.; Scott, A.M.; Rowe, C.C.

    2002-01-01

    Full text: The Department of Nuclear Medicine, Centre for PET at the ARMC is commissioning a next generation PET/CT scanner based on gadolinium silicic dioxide (GSO) crystal technology to replace the BGO crystal PET scanner that has been in operation since 1992. The Gemini PET/CT scanner is a fully 3D PET system which offers significantly increased resolution and sensitivity allowing wholebody scans in under 30 minutes. Until the late 90's, PET scanners were largely used with septa for neurological imaging and the performance characteristics of PET scanners were presented according to the NEMA-NU2-94 standard which specifically addresses the performance of PET scanners for neurological applications. PET is now largely used without septa for oncological imaging and as such, the NEMA-NU2-94 standard does not adequately reflect performance. The NEMA-NU2-2001 standard was designed to incorporate the effects of out-of-FOV activity and its contribution to performance by virtue of the increased scatter and randoms that result when performing wholebody scans without the use of septa. As part of the acceptance program of the Allegro/Gemini systems, the NEMA-NU2-2001 standard will be used to characterise the spatial resolution, sensitivity, randoms and scatter contributions and the Noise Equivalent Count rate (NECr). These results will be presented and compared with the ECAT 951/31R performance characteristics. Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  20. Aerial Photography and Imagery, Ortho-Corrected - VOLUSIA 2006 Orthophotography

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — 2006, 6 inch Pixel Color Orthophotography - - Panchromatic, red, green, blue and near infrared imagery was acquired using the Leica ADS40 multi-spectral scanner (see...

  1. Addressing Spatial Variability of Surface-Layer Wind with Long-Range WindScanners

    DEFF Research Database (Denmark)

    Berg, Jacob; Vasiljevic, Nikola; Kelly, Mark C.

    2015-01-01

    of the WindScanner data is high, although the fidelity of the estimated vertical velocity component is significantly limited by the elevation angles of the scanner heads. The system of long-range WindScanners presented in this paper is close to being fully operational, with the pilot study herein serving...

  2. NOAA-9 Earth Radiation Budget Experiment (ERBE) scanner offsets determination

    Science.gov (United States)

    Avis, Lee M.; Paden, Jack; Lee, Robert B., III; Pandey, Dhirendra K.; Stassi, Joseph C.; Wilson, Robert S.; Tolson, Carol J.; Bolden, William C.

    1994-01-01

    The Earth Radiation Budget Experiment (ERBE) instruments are designed to measure the components of the radiative exchange between the Sun, Earth and space. ERBE is comprised of three spacecraft, each carrying a nearly identical set of radiometers: a three-channel narrow-field-of-view scanner, a two-channel wide-field-of-view (limb-to-limb) non-scanning radiometer, a two-channel medium field-of view (1000 km) non-scanning radiometer, and a solar monitor. Ground testing showed the scanners to be susceptible to self-generated and externally generated electromagnetic noise. This paper describes the pre-launch corrective measures taken and the post-launch corrections to the NOAA-9 scanner data. The NOAA-9 scanner has met the mission objectives in accuracy and precision, in part because of the pre-launch reductions of and post-launch data corrections for the electromagnetic noise.

  3. Improved quality of image got through whole-body CT scanner

    International Nuclear Information System (INIS)

    Asahina, Kiyotaka

    1980-01-01

    The quality of brain images taken with a whole-body CT scanner has so far been generally inferior in quality to those got through a CT scanner exclusively used for brains. In order to improve the whole-body CT scanner so as to get better brain image, its detection system has been made multichannel; the capacity of its X-ray tube, increased; and its software, innovated. As a result, the spatial resolution has been improved from 5.51 p/cm to 9.01 p/cm, the contrast resolution has been improved from 3.2 mm% to 1.5 mm%, with the noise maintained at 0.5%. In clinical examination, the image quality has been improved equally well for brains, abdomens and lungs. Especially high appreciation is given to the diagnosis information got through this new scanner. (author)

  4. Spectral correction algorithm for multispectral CdTe x-ray detectors

    DEFF Research Database (Denmark)

    Christensen, Erik D.; Kehres, Jan; Gu, Yun

    2017-01-01

    Compared to the dual energy scintillator detectors widely used today, pixelated multispectral X-ray detectors show the potential to improve material identification in various radiography and tomography applications used for industrial and security purposes. However, detector effects, such as charge...

  5. Off-Resonance Suppression for Multispectral MR Imaging Near Metallic Implants

    NARCIS (Netherlands)

    den Harder, J. Chiel; van Yperen, Gert H.; Blume, Ulrike A.; Bos, Clemens

    Purpose: Metal artifact reduction in MRI within clinically feasible scan-times without through-plane aliasing. Theory and Methods: Existing metal artifact reduction techniques include view angle tilting (VAT), which resolves in-plane distortions, and multispectral imaging (MSI) techniques, such as

  6. The CT scanner as a therapy machine

    International Nuclear Information System (INIS)

    Iwamoto, K.S.; Norman, A.

    1990-01-01

    Many tumors in the brain and in other tissues can be delineated precisely in images obtained with a CT scanner. After the scan is obtained the patient is taken to another room for radiation therapy and is positioned in the beam with the aid of external markers, simulators or stereotactic devices. This procedure is time consuming and subject to error when precise localization of the beam is desired. The CT scanner itself, with the addition of the collimator, is capable of delivering radiation therapy with great precision without the need for external markers. The patient can be scanned and treated on the same table, the isocenter of the beam can be placed precisely in the center of the lesion, the beam can be restricted to just those planes in which the lesion appears, several arcs can be obtained by simply tilting the gantry, and the position of the patient in the beam can be monitored continuously during therapy. The authors describe the properties of the CTX, the CT scanner modified for therapy. (author). 6 refs.; 6 figs

  7. A comparison of autonomous techniques for multispectral image analysis and classification

    Science.gov (United States)

    Valdiviezo-N., Juan C.; Urcid, Gonzalo; Toxqui-Quitl, Carina; Padilla-Vivanco, Alfonso

    2012-10-01

    Multispectral imaging has given place to important applications related to classification and identification of objects from a scene. Because of multispectral instruments can be used to estimate the reflectance of materials in the scene, these techniques constitute fundamental tools for materials analysis and quality control. During the last years, a variety of algorithms has been developed to work with multispectral data, whose main purpose has been to perform the correct classification of the objects in the scene. The present study introduces a brief review of some classical as well as a novel technique that have been used for such purposes. The use of principal component analysis and K-means clustering techniques as important classification algorithms is here discussed. Moreover, a recent method based on the min-W and max-M lattice auto-associative memories, that was proposed for endmember determination in hyperspectral imagery, is introduced as a classification method. Besides a discussion of their mathematical foundation, we emphasize their main characteristics and the results achieved for two exemplar images conformed by objects similar in appearance, but spectrally different. The classification results state that the first components computed from principal component analysis can be used to highlight areas with different spectral characteristics. In addition, the use of lattice auto-associative memories provides good results for materials classification even in the cases where some spectral similarities appears in their spectral responses.

  8. Database on aircraft accidents

    International Nuclear Information System (INIS)

    Nishio, Masahide; Koriyama, Tamio

    2012-09-01

    The Reactor Safety Subcommittee in the Nuclear Safety and Preservation Committee published the report 'The criteria on assessment of probability of aircraft crash into light water reactor facilities' as the standard method for evaluating probability of aircraft crash into nuclear reactor facilities in July 2002. In response to the report, Japan Nuclear Energy Safety Organization has been collecting open information on aircraft accidents of commercial airplanes, self-defense force (SDF) airplanes and US force airplanes every year since 2003, sorting out them and developing the database of aircraft accidents for latest 20 years to evaluate probability of aircraft crash into nuclear reactor facilities. This year, the database was revised by adding aircraft accidents in 2010 to the existing database and deleting aircraft accidents in 1991 from it, resulting in development of the revised 2011 database for latest 20 years from 1991 to 2010. Furthermore, the flight information on commercial aircrafts was also collected to develop the flight database for latest 20 years from 1991 to 2010 to evaluate probability of aircraft crash into reactor facilities. The method for developing the database of aircraft accidents to evaluate probability of aircraft crash into reactor facilities is based on the report 'The criteria on assessment of probability of aircraft crash into light water reactor facilities' described above. The 2011 revised database for latest 20 years from 1991 to 2010 shows the followings. The trend of the 2011 database changes little as compared to the last year's one. (1) The data of commercial aircraft accidents is based on 'Aircraft accident investigation reports of Japan transport safety board' of Ministry of Land, Infrastructure, Transport and Tourism. 4 large fixed-wing aircraft accidents, 58 small fixed-wing aircraft accidents, 5 large bladed aircraft accidents and 114 small bladed aircraft accidents occurred. The relevant accidents for evaluating

  9. Computer-aided analysis of digital dental impressions obtained from intraoral and extraoral scanners.

    Science.gov (United States)

    Bohner, Lauren Oliveira Lima; De Luca Canto, Graziela; Marció, Bruno Silva; Laganá, Dalva Cruz; Sesma, Newton; Tortamano Neto, Pedro

    2017-11-01

    The internal and marginal adaptation of a computer-aided design and computer-aided manufacturing (CAD-CAM) prosthesis relies on the quality of the 3-dimensional image. The quality of imaging systems requires evaluation. The purpose of this in vitro study was to evaluate and compare the trueness of intraoral and extraoral scanners in scanning prepared teeth. Ten acrylic resin teeth to be used as a reference dataset were prepared according to standard guidelines and scanned with an industrial computed tomography system. Data were acquired with 4 scanner devices (n=10): the Trios intraoral scanner (TIS), the D250 extraoral scanner (DES), the Cerec Bluecam intraoral scanner (CBIS), and the Cerec InEosX5 extraoral scanner (CIES). For intraoral scanners, each tooth was digitized individually. Extraoral scanning was obtained from dental casts of each prepared tooth. The discrepancy between each scan and its respective reference model was obtained by deviation analysis (μm) and volume/area difference (μm). Statistical analysis was performed using linear models for repeated measurement factors test and 1-way ANOVA (α=.05). No significant differences in deviation values were found among scanners. For CBIS and CIES, the deviation was significantly higher (PDentistry. Published by Elsevier Inc. All rights reserved.

  10. Initial results of the quality control in 11 computed tomography scanners at Curitiba

    International Nuclear Information System (INIS)

    Kodlulovich, S; Oliveira, L.; Jakubiak, R.R.; Miquelin, C.A.

    2008-01-01

    The aim of this study was to evaluate the image quality of 11 scanners installed in public and private centers of Curitiba, Brazil. This sample represents 30% of the CT scanners in the city so far. The ACR CT accreditation phantom was used to verify the accomplishment of the scanners performance to the international quality requirements. The results indicate that efforts should be concentrated in the maintenance of the equipments and specific training of the technicians. Most of the scanners have showed some non-conformity. In 27,5% of the sample the positioning requirement wasn't accomplished. The CT number accuracy evaluation showed that in 72,3 % of the scanners the CT numbers were out of the tolerance range, reaching values 35% greater than the limit. The low contrast resolution criteria weren't accomplished in 9% of the scanners. The main concern is that there isn't a specific program to evaluate the image quality of the CT scanners neither to estimate the CT doses in the procedures. (author)

  11. 14 CFR 21.6 - Manufacture of new aircraft, aircraft engines, and propellers.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Manufacture of new aircraft, aircraft... Manufacture of new aircraft, aircraft engines, and propellers. (a) Except as specified in paragraphs (b) and (c) of this section, no person may manufacture a new aircraft, aircraft engine, or propeller based on...

  12. Database on aircraft accidents

    International Nuclear Information System (INIS)

    Nishio, Masahide; Koriyama, Tamio

    2013-11-01

    The Reactor Safety Subcommittee in the Nuclear Safety and Preservation Committee published 'The criteria on assessment of probability of aircraft crash into light water reactor facilities' as the standard method for evaluating probability of aircraft crash into nuclear reactor facilities in July 2002. In response to this issue, Japan Nuclear Energy Safety Organization has been collecting open information on aircraft accidents of commercial airplanes, self-defense force (SDF) airplanes and US force airplanes every year since 2003, sorting out them and developing the database of aircraft accidents for the latest 20 years to evaluate probability of aircraft crash into nuclear reactor facilities. In this report the database was revised by adding aircraft accidents in 2011 to the existing database and deleting aircraft accidents in 1991 from it, resulting in development of the revised 2012 database for the latest 20 years from 1992 to 2011. Furthermore, the flight information on commercial aircrafts was also collected to develop the flight database for the latest 20 years from 1992 to 2011 to evaluate probability of aircraft crash into reactor facilities. The method for developing the database of aircraft accidents to evaluate probability of aircraft crash into reactor facilities is based on the report 'The criteria on assessment of probability of aircraft crash into light water reactor facilities' described above. The 2012 revised database for the latest 20 years from 1992 to 2011 shows the followings. The trend of the 2012 database changes little as compared to the last year's report. (1) The data of commercial aircraft accidents is based on 'Aircraft accident investigation reports of Japan transport safety board' of Ministry of Land, Infrastructure, Transport and Tourism. The number of commercial aircraft accidents is 4 for large fixed-wing aircraft, 58 for small fixed-wing aircraft, 5 for large bladed aircraft and 99 for small bladed aircraft. The relevant accidents

  13. Multispectral x-ray CT: multivariate statistical analysis for efficient reconstruction

    DEFF Research Database (Denmark)

    Kheirabadi, Mina; Mustafa, Wail; Lyksborg, Mark

    2017-01-01

    Recent developments in multispectral X-ray detectors allow for an efficient identification of materials based on their chemical composition. This has a range of applications including security inspection, which is our motivation. In this paper, we analyze data from a tomographic setup employing...

  14. Development of a Mobile Multispectral Imaging Platform for Precise Field Phenotyping

    Czech Academy of Sciences Publication Activity Database

    Svensgaard, J.; Roitsch, Thomas; Christensen, C.

    2014-01-01

    Roč. 4, č. 3 (2014), s. 322-336 ISSN 2073-4395 Institutional support: RVO:67179843 Keywords : field phenotyping * multispectral imaging * supervised classification * canonical discriminant analysis * vegetation coverage * NDVI Subject RIV: EH - Ecology, Behaviour

  15. Design Optimization of a TOF, Breast PET Scanner

    OpenAIRE

    Lee, Eunsin; Werner, Matthew E.; Karp, Joel S.; Surti, Suleman

    2013-01-01

    A dedicated breast positron emission tomography (PET) scanner with limited angle geometry can provide flexibility in detector placement around the patient as well as the ability to combine it with other imaging modalities. A primary challenge of a stationary limited angle scanner is the reduced image quality due to artifacts present in the reconstructed image leading to a loss in quantitative information. Previously it has been shown that using time-of-flight (TOF) information in image recons...

  16. A rural CT scanner: evaluating the effect on local health care

    International Nuclear Information System (INIS)

    Merkens, B.J.; Mowbray, R.D.; Creeden, L.; Engels, P.T.; Rothwell, D.M.; Chan, B.T.B.; Tu, K.

    2006-01-01

    The first small rural hospital in Ontario to propose a computed tomography (CT) scanner was in Walkerton, a town 160 km north of London. The Ontario Ministry of Health approved the proposal as a pilot project to evaluate the effect on local health care of a rural scanner. This evaluation study had 3 parts: a survey of physicians, a survey of patients, and an analysis of population CT scanning rates. The physicians in the area served by the scanner were asked about its impact on their care of their patients in a mailed questionnaire and in semistructured interviews. Scanner outpatients were given a questionnaire in which they rated the importance of its advantages. The analysis of scanning rates--the ratio of number of scans to estimated population--compared rates in the area with other Ontario rates before and after the scanner was introduced. The physicians reported that local CT allowed them to diagnose and treat patients sooner, closer to home, and with greater confidence. On average, 75% of the patients ranked faster and closer access as very important. Scanning rates in the area rose, although they did not match urban rates. The study confirms that the rural scanner changed the area's health care in significant ways and that it helped to narrow the gap between rural and urban service levels. We recommend that CT be expanded to other rural regions. (author)

  17. Verification of a CT scanner using a miniature step gauge

    DEFF Research Database (Denmark)

    Cantatore, Angela; Andreasen, J.L.; Carmignato, S.

    2011-01-01

    The work deals with performance verification of a CT scanner using a 42mm miniature replica step gauge developed for optical scanner verification. Errors quantification and optimization of CT system set-up in terms of resolution and measurement accuracy are fundamental for use of CT scanning...

  18. Multispectral linear array (MLA) focal plane mechanical and thermal design

    Science.gov (United States)

    Mitchell, A. S.; Kaminski, E. F.

    1982-01-01

    The mechanical and thermal design of an integrated focal plane subsystem of a Multispectral Linear Array (MLA) instrument is discussed in terms of focal-plane alignment, thermoelastic performance, and thermal requirements. The modular construction and thermal control of the focal plane array are discussed.

  19. Comparing Individual Tree Segmentation Based on High Resolution Multispectral Image and Lidar Data

    Science.gov (United States)

    Xiao, P.; Kelly, M.; Guo, Q.

    2014-12-01

    This study compares the use of high-resolution multispectral WorldView images and high density Lidar data for individual tree segmentation. The application focuses on coniferous and deciduous forests in the Sierra Nevada Mountains. The tree objects are obtained in two ways: a hybrid region-merging segmentation method with multispectral images, and a top-down and bottom-up region-growing method with Lidar data. The hybrid region-merging method is used to segment individual tree from multispectral images. It integrates the advantages of global-oriented and local-oriented region-merging strategies into a unified framework. The globally most-similar pair of regions is used to determine the starting point of a growing region. The merging iterations are constrained within the local vicinity, thus the segmentation is accelerated and can reflect the local context. The top-down region-growing method is adopted in coniferous forest to delineate individual tree from Lidar data. It exploits the spacing between the tops of trees to identify and group points into a single tree based on simple rules of proximity and likely tree shape. The bottom-up region-growing method based on the intensity and 3D structure of Lidar data is applied in deciduous forest. It segments tree trunks based on the intensity and topological relationships of the points, and then allocate other points to exact tree crowns according to distance. The accuracies for each method are evaluated with field survey data in several test sites, covering dense and sparse canopy. Three types of segmentation results are produced: true positive represents a correctly segmented individual tree, false negative represents a tree that is not detected and assigned to a nearby tree, and false positive represents that a point or pixel cluster is segmented as a tree that does not in fact exist. They respectively represent correct-, under-, and over-segmentation. Three types of index are compared for segmenting individual tree

  20. Quality assurance for MR stereotactic imaging for three Siemens scanners

    International Nuclear Information System (INIS)

    Kozubikova, P.; Novotny, J. Jr.; Kulhova, K.; Mihalova, P.; Tamasova, J.; Veselsk, T.

    2014-01-01

    Quality assurance of stereotactic imaging, especially with MRI (magnetic resonance imaging), is a complex issue. It can be divided in the basic verification and commissioning of a particular new scanner or a new scanning MRI protocol that is being implemented into a clinical practice and the routine quality assurance performed for each single radiosurgical case. The aim of this study was geometric distortion assessment in MRI with a special PTGR (Physikalisch-Technische Gesellschaft fuer Radiologie - GmbH, Tuebingen, Germany) target phantom. PTGR phantom consists of 21 three-dimensional cross-hairs filled with contrast medium. Cross hairs are positioned at known Leksell coordinates with a precision of better than 0.1 mm and covering the whole stereotactic space. The phantom can be fixed in the Leksell stereotactic frame and thus stereotactic imaging procedures can be reproduced following exactly the same steps as for a real patient, including also the stereotactic image definition in the Leksell GammaPlan. Since the geometric position (stereotactic coordinates) of each cross-hair is known based on the construction of the phantom, it can be compared with the actual measured Leksell coordinates based on the stereotactic MRI. Deviations between expected and actual coordinates provide information about the level of distortion. The measured distortions proved satisfactory accuracy precision for stereotactic localization at 1.5 T Siemens Magnetom Avanto scanner, Siemens Magnetom Symphony scanner and 3T Siemens Magnetom Skyra scanner (Na Homolce Hospital, Prague). The mean distortion for these MR scanners for standard imaging protocol (T1 weighted 3D images) were 0.8 mm, 1.1 mm and 1.1 mm and maximum distortions were 1.3 mm, 1.9 mm and 2.2 mm, respectively.There was detected dependence of the distortions on the slice orientation and the type of imaging protocol. Image distortions are also property of each particular scanner, the worst distortion were observed for 3T

  1. Portable Multispectral Colorimeter for Metallic Ion Detection and Classification.

    Science.gov (United States)

    Braga, Mauro S; Jaimes, Ruth F V V; Borysow, Walter; Gomes, Osmar F; Salcedo, Walter J

    2017-07-28

    This work deals with a portable device system applied to detect and classify different metallic ions as proposed and developed, aiming its application for hydrological monitoring systems such as rivers, lakes and groundwater. Considering the system features, a portable colorimetric system was developed by using a multispectral optoelectronic sensor. All the technology of quantification and classification of metallic ions using optoelectronic multispectral sensors was fully integrated in the embedded hardware FPGA ( Field Programmable Gate Array) technology and software based on virtual instrumentation (NI LabView ® ). The system draws on an indicative colorimeter by using the chromogen reagent of 1-(2-pyridylazo)-2-naphthol (PAN). The results obtained with the signal processing and pattern analysis using the method of the linear discriminant analysis, allows excellent results during detection and classification of Pb(II), Cd(II), Zn(II), Cu(II), Fe(III) and Ni(II) ions, with almost the same level of performance as for those obtained from the Ultravioled and visible (UV-VIS) spectrophotometers of high spectral resolution.

  2. An Algorithm for Pedestrian Detection in Multispectral Image Sequences

    Science.gov (United States)

    Kniaz, V. V.; Fedorenko, V. V.

    2017-05-01

    The growing interest for self-driving cars provides a demand for scene understanding and obstacle detection algorithms. One of the most challenging problems in this field is the problem of pedestrian detection. Main difficulties arise from a diverse appearances of pedestrians. Poor visibility conditions such as fog and low light conditions also significantly decrease the quality of pedestrian detection. This paper presents a new optical flow based algorithm BipedDetet that provides robust pedestrian detection on a single-borad computer. The algorithm is based on the idea of simplified Kalman filtering suitable for realization on modern single-board computers. To detect a pedestrian a synthetic optical flow of the scene without pedestrians is generated using slanted-plane model. The estimate of a real optical flow is generated using a multispectral image sequence. The difference of the synthetic optical flow and the real optical flow provides the optical flow induced by pedestrians. The final detection of pedestrians is done by the segmentation of the difference of optical flows. To evaluate the BipedDetect algorithm a multispectral dataset was collected using a mobile robot.

  3. Portable Multispectral Colorimeter for Metallic Ion Detection and Classification

    Directory of Open Access Journals (Sweden)

    Mauro S. Braga

    2017-07-01

    Full Text Available This work deals with a portable device system applied to detect and classify different metallic ions as proposed and developed, aiming its application for hydrological monitoring systems such as rivers, lakes and groundwater. Considering the system features, a portable colorimetric system was developed by using a multispectral optoelectronic sensor. All the technology of quantification and classification of metallic ions using optoelectronic multispectral sensors was fully integrated in the embedded hardware FPGA ( Field Programmable Gate Array technology and software based on virtual instrumentation (NI LabView®. The system draws on an indicative colorimeter by using the chromogen reagent of 1-(2-pyridylazo-2-naphthol (PAN. The results obtained with the signal processing and pattern analysis using the method of the linear discriminant analysis, allows excellent results during detection and classification of Pb(II, Cd(II, Zn(II, Cu(II, Fe(III and Ni(II ions, with almost the same level of performance as for those obtained from the Ultravioled and visible (UV-VIS spectrophotometers of high spectral resolution.

  4. Defense Commissaries: Issues Related to the Sale of Electronic Scanner Data

    National Research Council Canada - National Science Library

    1998-01-01

    In response to your request that we review DeCA'S sale of scanner data and its implementation of category management, this report identifies DeCA'S total revenue from selling scanner data and compares license revenues...

  5. Ultra-High-Resolution Computed Tomography of the Lung: Image Quality of a Prototype Scanner

    Science.gov (United States)

    Kakinuma, Ryutaro; Moriyama, Noriyuki; Muramatsu, Yukio; Gomi, Shiho; Suzuki, Masahiro; Nagasawa, Hirobumi; Kusumoto, Masahiko; Aso, Tomohiko; Muramatsu, Yoshihisa; Tsuchida, Takaaki; Tsuta, Koji; Maeshima, Akiko Miyagi; Tochigi, Naobumi; Watanabe, Shun-ichi; Sugihara, Naoki; Tsukagoshi, Shinsuke; Saito, Yasuo; Kazama, Masahiro; Ashizawa, Kazuto; Awai, Kazuo; Honda, Osamu; Ishikawa, Hiroyuki; Koizumi, Naoya; Komoto, Daisuke; Moriya, Hiroshi; Oda, Seitaro; Oshiro, Yasuji; Yanagawa, Masahiro; Tomiyama, Noriyuki; Asamura, Hisao

    2015-01-01

    Purpose The image noise and image quality of a prototype ultra-high-resolution computed tomography (U-HRCT) scanner was evaluated and compared with those of conventional high-resolution CT (C-HRCT) scanners. Materials and Methods This study was approved by the institutional review board. A U-HRCT scanner prototype with 0.25 mm x 4 rows and operating at 120 mAs was used. The C-HRCT images were obtained using a 0.5 mm x 16 or 0.5 mm x 64 detector-row CT scanner operating at 150 mAs. Images from both scanners were reconstructed at 0.1-mm intervals; the slice thickness was 0.25 mm for the U-HRCT scanner and 0.5 mm for the C-HRCT scanners. For both scanners, the display field of view was 80 mm. The image noise of each scanner was evaluated using a phantom. U-HRCT and C-HRCT images of 53 images selected from 37 lung nodules were then observed and graded using a 5-point score by 10 board-certified thoracic radiologists. The images were presented to the observers randomly and in a blinded manner. Results The image noise for U-HRCT (100.87 ± 0.51 Hounsfield units [HU]) was greater than that for C-HRCT (40.41 ± 0.52 HU; P < .0001). The image quality of U-HRCT was graded as superior to that of C-HRCT (P < .0001) for all of the following parameters that were examined: margins of subsolid and solid nodules, edges of solid components and pulmonary vessels in subsolid nodules, air bronchograms, pleural indentations, margins of pulmonary vessels, edges of bronchi, and interlobar fissures. Conclusion Despite a larger image noise, the prototype U-HRCT scanner had a significantly better image quality than the C-HRCT scanners. PMID:26352144

  6. Ultra-High-Resolution Computed Tomography of the Lung: Image Quality of a Prototype Scanner.

    Directory of Open Access Journals (Sweden)

    Ryutaro Kakinuma

    Full Text Available The image noise and image quality of a prototype ultra-high-resolution computed tomography (U-HRCT scanner was evaluated and compared with those of conventional high-resolution CT (C-HRCT scanners.This study was approved by the institutional review board. A U-HRCT scanner prototype with 0.25 mm x 4 rows and operating at 120 mAs was used. The C-HRCT images were obtained using a 0.5 mm x 16 or 0.5 mm x 64 detector-row CT scanner operating at 150 mAs. Images from both scanners were reconstructed at 0.1-mm intervals; the slice thickness was 0.25 mm for the U-HRCT scanner and 0.5 mm for the C-HRCT scanners. For both scanners, the display field of view was 80 mm. The image noise of each scanner was evaluated using a phantom. U-HRCT and C-HRCT images of 53 images selected from 37 lung nodules were then observed and graded using a 5-point score by 10 board-certified thoracic radiologists. The images were presented to the observers randomly and in a blinded manner.The image noise for U-HRCT (100.87 ± 0.51 Hounsfield units [HU] was greater than that for C-HRCT (40.41 ± 0.52 HU; P < .0001. The image quality of U-HRCT was graded as superior to that of C-HRCT (P < .0001 for all of the following parameters that were examined: margins of subsolid and solid nodules, edges of solid components and pulmonary vessels in subsolid nodules, air bronchograms, pleural indentations, margins of pulmonary vessels, edges of bronchi, and interlobar fissures.Despite a larger image noise, the prototype U-HRCT scanner had a significantly better image quality than the C-HRCT scanners.

  7. Development of a Portable 3CCD Camera System for Multispectral Imaging of Biological Samples

    Science.gov (United States)

    Lee, Hoyoung; Park, Soo Hyun; Noh, Sang Ha; Lim, Jongguk; Kim, Moon S.

    2014-01-01

    Recent studies have suggested the need for imaging devices capable of multispectral imaging beyond the visible region, to allow for quality and safety evaluations of agricultural commodities. Conventional multispectral imaging devices lack flexibility in spectral waveband selectivity for such applications. In this paper, a recently developed portable 3CCD camera with significant improvements over existing imaging devices is presented. A beam-splitter prism assembly for 3CCD was designed to accommodate three interference filters that can be easily changed for application-specific multispectral waveband selection in the 400 to 1000 nm region. We also designed and integrated electronic components on printed circuit boards with firmware programming, enabling parallel processing, synchronization, and independent control of the three CCD sensors, to ensure the transfer of data without significant delay or data loss due to buffering. The system can stream 30 frames (3-waveband images in each frame) per second. The potential utility of the 3CCD camera system was demonstrated in the laboratory for detecting defect spots on apples. PMID:25350510

  8. Evaluation of a LED-based flatbed document scanner for radiochromic film dosimetry in transmission mode.

    Science.gov (United States)

    Lárraga-Gutiérrez, José Manuel; García-Garduño, Olivia Amanda; Treviño-Palacios, Carlos; Herrera-González, José Alfredo

    2018-03-01

    Flatbed scanners are the most frequently used reading instrument for radiochromic film dosimetry because its low cost, high spatial resolution, among other advantages. These scanners use a fluorescent lamp and a CCD array as light source and detector, respectively. Recently, manufacturers of flatbed scanners replaced the fluorescent lamp by light emission diodes (LED) as a light source. The goal of this work is to evaluate the performance of a commercial flatbed scanner with LED based source light for radiochromic film dosimetry. Film read out consistency, response uniformity, film-scanner sensitivity, long term stability and total dose uncertainty was evaluated. In overall, the performance of the LED flatbed scanner is comparable to that of a cold cathode fluorescent lamp (CCFL). There are important spectral differences between LED and CCFL lamps that results in a higher sensitivity of the LED scanner in the green channel. Total dose uncertainty, film response reproducibility and long-term stability of LED scanner are slightly better than those of the CCFL. However, the LED based scanner has a strong non-uniform response, up to 9%, that must be adequately corrected for radiotherapy dosimetry QA. The differences in light emission spectra between LED and CCFL lamps and its potential impact on film-scanner sensitivity suggest that the design of a dedicated flat-bed scanner with LEDs may improve sensitivity and dose uncertainty in radiochromic film dosimetry. Copyright © 2018 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  9. SU-E-T-135: Investigation of Commercial-Grade Flatbed Scanners and a Medical- Grade Scanner for Radiochromic EBT Film Dosimetry.

    Science.gov (United States)

    Syh, J; Patel, B; Syh, J; Wu, H; Rosen, L; Durci, M; Katz, S; Sibata, C

    2012-06-01

    To evaluate the characteristics of commercial-grade flatbed scanners and medical-grade scanners for radiochromic EBT film dosimetry. Performance aspects of a Vidar Dosimetry Pro Advantage (Red), Epson 750 Pro, Microtek ArtixScan 1800f, and Microtek ScanMaker 8700 scanner for EBT2 Gafchromic film were evaluated in the categories of repeatability, maximum distinguishable optical density (OD) differentiation, OD variance, and dose curve characteristics. OD step film by Stouffer Industries containing 31 steps ranging from 0.05 to 3.62 OD was used. EBT films were irradiated with dose ranging from 20 to 600 cGy in 6×6 cm 2 field sizes and analyzed 24 hours later using RIT113 and Tomotherapy Film Analyzer software. Scans were performed in transmissive mode, landscape orientation, 16-bit image. The mean and standard deviation Analog to Digital (A/D) scanner value was measured by selecting a 3×3 mm 2 uniform area in the central region of each OD step from a total of 20 scans performed over several weeks. Repeatability was determined from the variance of OD step 0.38. Maximum distinguishable OD was defined as the last OD step whose range of A/D values does not overlap with its neighboring step. Repeatability uncertainty ranged from 0.1% for Vidar to 4% for Epson. Average standard deviation of OD steps ranged from 0.21% for Vidar to 6.4% for ArtixScan 1800f. Maximum distinguishable optical density ranged from 3.38 for Vidar to 1.32 for ScanMaker 8700. A/D range of each OD step corresponds to a dose range. Dose ranges of OD steps varied from 1% for Vidar to 20% for ScanMaker 8700. The Vidar exhibited a dose curve that utilized a broader range of OD values than the other scanners. Vidar exhibited higher maximum distinguishable OD, smaller variance in repeatability, smaller A/D value deviation per OD step, and a shallower dose curve with respect to OD. © 2012 American Association of Physicists in Medicine.

  10. Accuracy of complete-arch model using an intraoral video scanner: An in vitro study.

    Science.gov (United States)

    Jeong, Il-Do; Lee, Jae-Jun; Jeon, Jin-Hun; Kim, Ji-Hwan; Kim, Hae-Young; Kim, Woong-Chul

    2016-06-01

    Information on the accuracy of intraoral video scanners for long-span areas is limited. The purpose of this in vitro study was to evaluate and compare the trueness and precision of an intraoral video scanner, an intraoral still image scanner, and a blue-light scanner for the production of digital impressions. Reference scan data were obtained by scanning a complete-arch model. An identical model was scanned 8 times using an intraoral video scanner (CEREC Omnicam; Sirona) and an intraoral still image scanner (CEREC Bluecam; Sirona), and stone casts made from conventional impressions of the same model were scanned 8 times with a blue-light scanner as a control (Identica Blue; Medit). Accuracy consists of trueness (the extent to which the scan data differ from the reference scan) and precision (the similarity of the data from multiple scans). To evaluate precision, 8 scans were superimposed using 3-dimensional analysis software; the reference scan data were then superimposed to determine the trueness. Differences were analyzed using 1-way ANOVA and post hoc Tukey HSD tests (α=.05). Trueness in the video scanner group was not significantly different from that in the control group. However, the video scanner group showed significantly lower values than those of the still image scanner group for all variables (P<.05), except in tolerance range. The root mean square, standard deviations, and mean negative precision values for the video scanner group were significantly higher than those for the other groups (P<.05). Digital impressions obtained by the intraoral video scanner showed better accuracy for long-span areas than those captured by the still image scanner. However, the video scanner was less accurate than the laboratory scanner. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  11. Laser measuring scanners and their accuracy limits

    Science.gov (United States)

    Jablonski, Ryszard

    1993-09-01

    Scanning methods have gained the greater importance for some years now due to a short measuring time and wide range of application in flexible manufacturing processes. This paper is a summing up of the autho?s creative scientific work in the field of measuring scanners. The research conducted allowed to elaborate the optimal configurations of measuring systems based on the scanning method. An important part of the work was the analysis of a measuring scanner - as a transducer of an angle rotation into the linear displacement which resulted in obtaining its much higher accuracy and finally in working out a measuring scanner eliminating the use of an additional reference standard. The completion of the work is an attempt to determine an attainable accuracy limit of scanning measurement of both length and angle. Using a high stability deflector and a corrected scanning lens one can obtain the angle determination over 30 (or 2 mm) to an accuracy 0 (or 0 tm) when the measuring rate is 1000 Hz or the range d60 (4 mm) with accuracy 0 " (0 jim) and measurement frequency 6 Hz.

  12. Quantitative Assay for Starch by Colorimetry Using a Desktop Scanner

    Science.gov (United States)

    Matthews, Kurt R.; Landmark, James D.; Stickle, Douglas F.

    2004-01-01

    The procedure to produce standard curve for starch concentration measurement by image analysis using a color scanner and computer for data acquisition and color analysis is described. Color analysis is performed by a Visual Basic program that measures red, green, and blue (RGB) color intensities for pixels within the scanner image.

  13. Characterization of Canberra's Tomographic Gamma-Ray Can Scanner ('Can-TGS') - 13311

    Energy Technology Data Exchange (ETDEWEB)

    LeBlanc, P.J.; Lagana, J.; Kirkpatrick, J.; Nakazawa, D.; Smith, S. Kane; Venkataraman, R.; Villani, M.; Young, B.M. [Canberra Industries, 800 Research Parkway, Meriden, CT 06450 (United States)

    2013-07-01

    The Tomographic Gamma-ray Scanner (TGS) for large volume drummed waste has been successfully commercialized by Canberra over the last several years. As part of an R and D effort to continually improve this technology, we have developed a scaled down version of the standard commercial product (Can-TGS). The Can-TGS is able to accommodate cans and pails of various sizes, ranging from sub-liter to 20 liter volumes with densities of up to 4 g/cc. The Can-TGS has three diamond-shaped collimators (6.35 mm [0.25''], 12.7 mm [0.5''], and 25.4 mm [1'']) to facilitate a range of container volumes and heights. As with the standard TGS, the Can-TGS has a transmission source sub-system, where the transmission source can be easily swapped between sources of various strengths and type. The acquisition portion of the Can-TGS is powered by the Canberra Lynx{sup R} MCA which accommodates both multi-spectral scaling (MSS) and list-mode. Recently, the Can-TGS has been successfully characterized for an 18.93 L [5-gallon] container for the 25.4 mm diamond-shaped collimator. In principle, a single measurement (with good statistics) is required for each configuration in order to characterize the system. However, for this study, measurements were performed for several different matrices. For each matrix used, 6 different measurements were acquired. For each of these measurements, the drum was rotated 60 deg. with respect to the previous starting position. This procedure was followed in order to average out any radial bias that might be produced from just a single measurement. A description of the Can-TGS system is given. The details of the recent characterization measurements and the associated data analysis and results are presented. TGS results are compared with Segmented Gamma Scanner (SGS) results for the same source configuration. Additionally, the future outlook for Canberra's R and D efforts with this system is discussed. These efforts include TGS

  14. Highly Protable Airborne Multispectral Imaging System

    Science.gov (United States)

    Lehnemann, Robert; Mcnamee, Todd

    2001-01-01

    A portable instrumentation system is described that includes and airborne and a ground-based subsytem. It can acquire multispectral image data over swaths of terrain ranging in width from about 1.5 to 1 km. The system was developed especially for use in coastal environments and is well suited for performing remote sensing and general environmental monitoring. It includes a small,munpilotaed, remotely controlled airplance that carries a forward-looking camera for navigation, three downward-looking monochrome video cameras for imaging terrain in three spectral bands, a video transmitter, and a Global Positioning System (GPS) reciever.

  15. An improved feature extraction algorithm based on KAZE for multi-spectral image

    Science.gov (United States)

    Yang, Jianping; Li, Jun

    2018-02-01

    Multi-spectral image contains abundant spectral information, which is widely used in all fields like resource exploration, meteorological observation and modern military. Image preprocessing, such as image feature extraction and matching, is indispensable while dealing with multi-spectral remote sensing image. Although the feature matching algorithm based on linear scale such as SIFT and SURF performs strong on robustness, the local accuracy cannot be guaranteed. Therefore, this paper proposes an improved KAZE algorithm, which is based on nonlinear scale, to raise the number of feature and to enhance the matching rate by using the adjusted-cosine vector. The experiment result shows that the number of feature and the matching rate of the improved KAZE are remarkably than the original KAZE algorithm.

  16. Evaluation of Unmanned Aircraft Systems (UAS) for Weather and Climate using the Multi-testbed approach

    Science.gov (United States)

    Baker, B.; Lee, T.; Buban, M.; Dumas, E. J.

    2017-12-01

    Evaluation of Unmanned Aircraft Systems (UAS) for Weather and Climate using the Multi-testbed approachC. Bruce Baker1, Ed Dumas1,2, Temple Lee1,2, Michael Buban1,21NOAA ARL, Atmospheric Turbulence and Diffusion Division, Oak Ridge, TN2Oak Ridge Associated Universities, Oak Ridge, TN The development of a small Unmanned Aerial System (sUAS) testbeds that can be used to validate, integrate, calibrate and evaluate new technology and sensors for routine boundary layer research, validation of operational weather models, improvement of model parameterizations, and recording observations within high-impact storms is important for understanding the importance and impact of using sUAS's routinely as a new observing platform. The goal of the multi-testbed approach is to build a robust set of protocols to assess the cost and operational feasibility of unmanned observations for routine applications using various combinations of sUAS aircraft and sensors in different locations and field experiments. All of these observational testbeds serve different community needs, but they also use a diverse suite of methodologies for calibration and evaluation of different sensors and platforms for severe weather and boundary layer research. The primary focus will be to evaluate meteorological sensor payloads to measure thermodynamic parameters and define surface characteristics with visible, IR, and multi-spectral cameras. This evaluation will lead to recommendations for sensor payloads for VTOL and fixed-wing sUAS.

  17. Ghost signals in Allison emittance scanners

    International Nuclear Information System (INIS)

    Stockli, Martin P.; Leitner, M.; Moehs, D.P.; Keller, R.; Welton, R.F.

    2004-01-01

    For over 20 years, Allison scanners have been used to measure emittances of low-energy ion beams. We show that scanning large trajectory angles produces ghost signals caused by the sampled beamlet impacting on an electric deflection plate. The ghost signal strength is proportional to the amount of beam entering the scanner. Depending on the ions, and their velocity, the ghost signals can have the opposite or the same polarity as the main beam signals. The ghost signals cause significant errors in the emittance estimates because they appear at large trajectory angles. These ghost signals often go undetected because they partly overlap with the real signals, are mostly below the 1% level, and often hide in the noise. A simple deflection plate modification is shown to reduce the ghost signal strength by over 99%

  18. Ghost Signals In Allison Emittance Scanners

    International Nuclear Information System (INIS)

    Stockli, Martin P.; Leitner, M.; Keller, R.; Moehs, D.P.; Welton, R. F.

    2005-01-01

    For over 20 years, Allison scanners have been used to measure emittances of low-energy ion beams. We show that scanning large trajectory angles produces ghost signals caused by the sampled beamlet impacting on an electric deflection plate. The ghost signal strength is proportional to the amount of beam entering the scanner. Depending on the ions, and their velocity, the ghost signals can have the opposite or the same polarity as the main beam signals. The ghost signals cause significant errors in the emittance estimates because they appear at large trajectory angles. These ghost signals often go undetected because they partly overlap with the real signals, are mostly below the 1% level, and often hide in the noise. A simple deflection plate modification is shown to reduce the ghost signal strength by over 99%

  19. Comparison of working efficiency of terrestrial laser scanner in day and night conditions

    Science.gov (United States)

    Arslan, A. E.; Kalkan, K.

    2013-10-01

    Terrestrial Laser Scanning is a popular and widely used technique to scan existing objects, document historical sites and items, and remodel them if and when needed. Their ability to collect thousands of point data per second makes them an invaluable tool in many areas from engineering to historical reconstruction. There are many scanners in the market with different technical specifications. One main technical specification of laser scanners is range and illumination. In this study, it is tested to be determined the optimal working times of a laser scanner and the scanners consistency with its specifications sheet. In order to conduct this work, series of GNSS measurements in Istanbul Technical University have been carried out, connected to the national reference network, to determine precise positions of target points and the scanner, which makes possible to define a precise distance between the scanner and targets. Those ground surveys has been used for calibration and registration purposes. Two different scan campaigns conducted at 12 am and 11 pm to compare working efficiency of laser scanner in different illumination conditions and targets are measured with a handheld spectro-radiometer in order to determine their reflective characteristics. The obtained results are compared and their accuracies have been analysed.

  20. FormScanner: Open-Source Solution for Grading Multiple-Choice Exams

    Science.gov (United States)

    Young, Chadwick; Lo, Glenn; Young, Kaisa; Borsetta, Alberto

    2016-01-01

    The multiple-choice exam remains a staple for many introductory physics courses. In the past, people have graded these by hand or even flaming needles. Today, one usually grades the exams with a form scanner that utilizes optical mark recognition (OMR). Several companies provide these scanners and particular forms, such as the eponymous…

  1. The accuracy of the CAD system using intraoral and extraoral scanners for designing of fixed dental prostheses.

    Science.gov (United States)

    Shimizu, Sakura; Shinya, Akikazu; Kuroda, Soichi; Gomi, Harunori

    2017-07-26

    The accuracy of prostheses affects clinical success and is, in turn, affected by the accuracy of the scanner and CAD programs. Thus, their accuracy is important. The first aim of this study was to evaluate the accuracy of an intraoral scanner with active triangulation (Cerec Omnicam), an intraoral scanner with a confocal laser (3Shape Trios), and an extraoral scanner with active triangulation (D810). The second aim of this study was to compare the accuracy of the digital crowns designed with two different scanner/CAD combinations. The accuracy of the intraoral scanners and extraoral scanner was clinically acceptable. Marginal and internal fit of the digital crowns fabricated using the intraoral scanner and CAD programs were inferior to those fabricated using the extraoral scanner and CAD programs.

  2. Performance evaluation of 8 CT scanners for clinical use in Italy

    International Nuclear Information System (INIS)

    Pinto, I.; De Denaro, M.; Giribona, P.; Gicericin, C.; Bravar, D.

    1988-01-01

    In the past few years the use of CT scanners has widely spread in Italian care institutions. This methodology has thus become an important creates the need for an accurate study of the various aspects of the phenomenon, e.g. technological, diagnostic and economic. In order to evaluate the quality of the CT scanners used in our country, the majors suppliers of the Italian market were asked to provide us with a unit from their production. Six out of 7 companies complied with our request. A standard protocol was used to evaluate the performance of 8 CT scanners, currently used in Italy. The following parameters were evaluated: spatial resolution, contrast resolution, noise, slice thickness, uniformity, linearity and radiation dose. Five currently-used operating modalities were employed. The results allow an overall assessment of the performance of the 8 CT scanners

  3. Mechanical optimisation of a high-precision fast wire scanner at CERN

    CERN Document Server

    Samuelsson, Sebastian; Veness, Raymond

    Wire scanners are instruments used to measure the transverse beam prole in particle accelerators by passing a thin wire through the particle beam. To avoid the issues of vacuum leakage through the bellows and wire failure related to current designs of wire scanners, a new concept for a wire scanner has been developed at CERN. This design has all moving parts inside the beam vacuum and has a nominal wire scanning speed of 20 m/s. The demands on the design associated with this together with the high precision requirements create a need for\

  4. Transmitting Performance Evaluation of ASICs for CMUT-Based Portable Ultrasound Scanners

    DEFF Research Database (Denmark)

    Llimos Muntal, Pere; Diederichsen, Søren Elmin; Jørgensen, Ivan Harald Holger

    2017-01-01

    Portable ultrasound scanners (PUS) have, in recent years, raised a lot of attention, as they can potentially overcome some of the limitations of static scanners. However, PUS have a lot of design limitations including size and power consumption. These restrictions can compromise the image quality...... of the scanner. In order to overcome these restrictions, application specific integrated circuits (ASICs) are needed to implement the electronics. In this work, a comparative study of the transmitting performance of a capacitive micromachined ultrasonic transducer (CMUT) driven by a commercial generic ultrasound...

  5. Sensor Pods: Multi-Resolution Surveys from a Light Aircraft

    Directory of Open Access Journals (Sweden)

    Conor Cahalane

    2017-02-01

    Full Text Available Airborne remote sensing, whether performed from conventional aerial survey platforms such as light aircraft or the more recent Remotely Piloted Airborne Systems (RPAS has the ability to compliment mapping generated using earth-orbiting satellites, particularly for areas that may experience prolonged cloud cover. Traditional aerial platforms are costly but capture spectral resolution imagery over large areas. RPAS are relatively low-cost, and provide very-high resolution imagery but this is limited to small areas. We believe that we are the first group to retrofit these new, low-cost, lightweight sensors in a traditional aircraft. Unlike RPAS surveys which have a limited payload, this is the first time that a method has been designed to operate four distinct RPAS sensors simultaneously—hyperspectral, thermal, hyper, RGB, video. This means that imagery covering a broad range of the spectrum captured during a single survey, through different imaging capture techniques (frame, pushbroom, video can be applied to investigate different multiple aspects of the surrounding environment such as, soil moisture, vegetation vitality, topography or drainage, etc. In this paper, we present the initial results validating our innovative hybrid system adapting dedicated RPAS sensors for a light aircraft sensor pod, thereby providing the benefits of both methodologies. Simultaneous image capture with a Nikon D800E SLR and a series of dedicated RPAS sensors, including a FLIR thermal imager, a four-band multispectral camera and a 100-band hyperspectral imager was enabled by integration in a single sensor pod operating from a Cessna c172. However, to enable accurate sensor fusion for image analysis, each sensor must first be combined in a common vehicle coordinate system and a method for triggering, time-stamping and calculating the position/pose of each sensor at the time of image capture devised. Initial tests were carried out over agricultural regions with

  6. ERTS-1 Virgin Islands experiment 589: Determine boundaries of ERTS and aircraft data within which useful water quality information can be obtained. [water pollution in St. Thomas harbor, Virgin Islands

    Science.gov (United States)

    Coulbourn, W. C.; Egan, W. G.; Olsen, D. A. (Principal Investigator); Heaslip, G. B.

    1973-01-01

    The author has identified the following significant results. The boundaries of application of ERTS-1 and aircraft data are established for St. Thomas harbor within which useful water quality information can be obtained. In situ physical, chemical, and biological water quality and benthic data were collected. Moored current meters were employed. Optical measurements of solar irradiance, color test panel radiance and water absorption were taken. Procedures for correlating in situ optical, biological, and chemical data with underflight aircraft I2S data and ERTS-1 MSS scanner data are presented. Comparison of bulk and precision CCT computer printout data for this application is made, and a simple method for geometrically locating bulk data individual pixels based on land-water interface is described. ERTS spacecraft data and I2S aircraft imagery are correlated with optical in situ measurements of the harbor water, with the aircraft green photographic and ERTS-1 MSS-4 bands being the most useful. The biological pigments correlate inversely with the optical data for inshore areas and directly further seaward. Automated computer data processing facilitated analysis.

  7. Active Damping of a Piezoelectric Tube Scanner using Self-Sensing Piezo Actuation

    Science.gov (United States)

    Kuiper, S.; Schitter, G.

    2010-01-01

    In most Atomic Force Microscopes (AFM), a piezoelectric tube scanner is used to position the sample underneath the measurement probe. Oscillations stemming from the weakly damped resonances of the tube scanner are a major source of image distortion, putting a limitation on the achievable imaging speed. This paper demonstrates active damping of these oscillations in multiple scanning axes without the need for additional position sensors. By connecting the tube scanner in a capacitive bridge circuit the scanner oscillations can be measured in both scanning axes, using the same piezo material as an actuator and sensor simultaneously. In order to compensate for circuit imbalance caused by hysteresis in the piezo element, an adaptive balancing circuit is used. The obtained measurement signal is used for feedback control, reducing the resonance peaks in both scanning axes by 18 dB and the cross-coupling at those frequencies by 30 dB. Experimental results demonstrate a significant reduction in scanner oscillations when applying the typical triangular scanning signals, as well as a strong reduction in coupling induced oscillations. Recorded AFM images show a considerable reduction in image distortion due to the proposed control method, enabling artifact free AFM imaging at a speed of 122 lines per second with a standard piezoelectric tube scanner. PMID:26412944

  8. Remote sensing and uranium exploration at Lisbon Valley, Utah

    International Nuclear Information System (INIS)

    Conel, J.E.; Niesen, P.L.

    1981-01-01

    Use was made of aircraft-acquired multispectral scanner data to investigate the distribution of bleaching in Wingate sandstone exposed in Lisbon Valley anticline, Utah. All of the large ore bodies contained in lower Chinle Triassic age or Cutler Permian age strate in this area lie beneath or closely adjacent to such bleached outcrops. The distribution of ore bodies and of bleached Wingate strata known from surface outcrops in the Big Indian District are also nearly completely contained within the oil and gas-producing limits of the Lisbon oil and gas and Big Indian gas fields. While there is little direct geologic connection discernible between the surface outcropping sandstones and ore bearing strata, the coincidences suggested this as a possible example of hydrocarbon or sour gas leakage influencing uranium ore deposition and rock alteration in superjacent strata. From a remote sensing point-of-view this study focuses on the distribution of Wingate bleaching. 7 refs

  9. Integration of heterogeneous data bases for development of a large-scale environmental data atlas for multi-platform PC and workstation users

    International Nuclear Information System (INIS)

    Bresnaham, P.J.; Cowen, D.J.; Jensen, J.R.; Ehler, G.B.; Mackey, H.E. Jr.

    1994-01-01

    Environmental monitoring and restoration at the Department of Energy's Savannah River Site (SRS) requires efficient access to large amounts of diverse spatial data. In order to handle this task the Environmental Sciences Section (ESS) of the Westinghouse Savannah River Company (WSRC) created an environmental data atlas that would use spatial keys to link all data sources to a common data base. These data include extensive information relating to both environmental and man-made features. The data were available in a multitude of different data structures, coordinate systems and formats. The final database also included multimedia information such as airborne multispectral scanner data, aircraft video, photography, bibliographic data, and scanned map bases. It was important that all of the data be readily accessible on the desktop of scientists regardless of the type of computer system they used. The purpose of this paper is to describe the creation of this extensive digital environmental data atlas

  10. Cyclone: A laser scanner for mobile robot navigation

    Science.gov (United States)

    Singh, Sanjiv; West, Jay

    1991-09-01

    Researchers at Carnegie Mellon's Field Robotics Center have designed and implemented a scanning laser rangefinder. The device uses a commercially available time-of-flight ranging instrument that is capable of making up to 7200 measurements per second. The laser beam is reflected by a rotating mirror, producing up to a 360 degree view. Mounted on a robot vehicle, the scanner can be used to detect obstacles in the vehicle's path or to locate the robot on a map. This report discusses the motivation, design, and some applications of the scanner.

  11. Science Applications of a Multispectral Microscopic Imager for the Astrobiological Exploration of Mars

    Science.gov (United States)

    Farmer, Jack D.; Sellar, R. Glenn; Swayze, Gregg A.; Blaney, Diana L.

    2014-01-01

    Abstract Future astrobiological missions to Mars are likely to emphasize the use of rovers with in situ petrologic capabilities for selecting the best samples at a site for in situ analysis with onboard lab instruments or for caching for potential return to Earth. Such observations are central to an understanding of the potential for past habitable conditions at a site and for identifying samples most likely to harbor fossil biosignatures. The Multispectral Microscopic Imager (MMI) provides multispectral reflectance images of geological samples at the microscale, where each image pixel is composed of a visible/shortwave infrared spectrum ranging from 0.46 to 1.73 μm. This spectral range enables the discrimination of a wide variety of rock-forming minerals, especially Fe-bearing phases, and the detection of hydrated minerals. The MMI advances beyond the capabilities of current microimagers on Mars by extending the spectral range into the infrared and increasing the number of spectral bands. The design employs multispectral light-emitting diodes and an uncooled indium gallium arsenide focal plane array to achieve a very low mass and high reliability. To better understand and demonstrate the capabilities of the MMI for future surface missions to Mars, we analyzed samples from Mars-relevant analog environments with the MMI. Results indicate that the MMI images faithfully resolve the fine-scale microtextural features of samples and provide important information to help constrain mineral composition. The use of spectral endmember mapping reveals the distribution of Fe-bearing minerals (including silicates and oxides) with high fidelity, along with the presence of hydrated minerals. MMI-based petrogenetic interpretations compare favorably with laboratory-based analyses, revealing the value of the MMI for future in situ rover-mediated astrobiological exploration of Mars. Key Words: Mars—Microscopic imager—Multispectral imaging

  12. Science applications of a multispectral microscopic imager for the astrobiological exploration of Mars.

    Science.gov (United States)

    Núñez, Jorge I; Farmer, Jack D; Sellar, R Glenn; Swayze, Gregg A; Blaney, Diana L

    2014-02-01

    Future astrobiological missions to Mars are likely to emphasize the use of rovers with in situ petrologic capabilities for selecting the best samples at a site for in situ analysis with onboard lab instruments or for caching for potential return to Earth. Such observations are central to an understanding of the potential for past habitable conditions at a site and for identifying samples most likely to harbor fossil biosignatures. The Multispectral Microscopic Imager (MMI) provides multispectral reflectance images of geological samples at the microscale, where each image pixel is composed of a visible/shortwave infrared spectrum ranging from 0.46 to 1.73 μm. This spectral range enables the discrimination of a wide variety of rock-forming minerals, especially Fe-bearing phases, and the detection of hydrated minerals. The MMI advances beyond the capabilities of current microimagers on Mars by extending the spectral range into the infrared and increasing the number of spectral bands. The design employs multispectral light-emitting diodes and an uncooled indium gallium arsenide focal plane array to achieve a very low mass and high reliability. To better understand and demonstrate the capabilities of the MMI for future surface missions to Mars, we analyzed samples from Mars-relevant analog environments with the MMI. Results indicate that the MMI images faithfully resolve the fine-scale microtextural features of samples and provide important information to help constrain mineral composition. The use of spectral endmember mapping reveals the distribution of Fe-bearing minerals (including silicates and oxides) with high fidelity, along with the presence of hydrated minerals. MMI-based petrogenetic interpretations compare favorably with laboratory-based analyses, revealing the value of the MMI for future in situ rover-mediated astrobiological exploration of Mars. Mars-Microscopic imager-Multispectral imaging-Spectroscopy-Habitability-Arm instrument.

  13. Thermo-mechanical design of a CW sweep plate emittance scanner

    International Nuclear Information System (INIS)

    Rathke, J.; Peacock, M.; Sredniawski, J.

    1996-01-01

    A sweep plate emittance scanner for use with high power, continuous wave (CW) beams has been designed, fabricated and commissioned at Northrop Grumman. The design is capable of scanning beams of up to 20 kW beam power with a spot diameter as small as 2 cm. The scanner pod is mounted on a ball screw driven linear bearing table that is driven through the beam by a stepper motor at velocities up to 30 cm/sec. This paper presents the thermo-mechanical analysis of the pod moving through a gaussian beam and the details of the mechanical design of the pod and motion system. Analyses to determine scanner cooling schemes and structural materials are presented. (author)

  14. Out of lab calibration of a rotating 2D scanner for 3D mapping

    Science.gov (United States)

    Koch, Rainer; Böttcher, Lena; Jahrsdörfer, Maximilian; Maier, Johannes; Trommer, Malte; May, Stefan; Nüchter, Andreas

    2017-06-01

    Mapping is an essential task in mobile robotics. To fulfil advanced navigation and manipulation tasks a 3D representation of the environment is required. Applying stereo cameras or Time-of-flight cameras (TOF cameras) are one way to archive this requirement. Unfortunately, they suffer from drawbacks which makes it difficult to map properly. Therefore, costly 3D laser scanners are applied. An inexpensive way to build a 3D representation is to use a 2D laser scanner and rotate the scan plane around an additional axis. A 3D point cloud acquired with such a custom device consists of multiple 2D line scans. Therefore the scanner pose of each line scan need to be determined as well as parameters resulting from a calibration to generate a 3D point cloud. Using external sensor systems are a common method to determine these calibration parameters. This is costly and difficult when the robot needs to be calibrated outside the lab. Thus, this work presents a calibration method applied on a rotating 2D laser scanner. It uses a hardware setup to identify the required parameters for calibration. This hardware setup is light, small, and easy to transport. Hence, an out of lab calibration is possible. Additional a theoretical model was created to test the algorithm and analyse impact of the scanner accuracy. The hardware components of the 3D scanner system are an HOKUYO UTM-30LX-EW 2D laser scanner, a Dynamixel servo-motor, and a control unit. The calibration system consists of an hemisphere. In the inner of the hemisphere a circular plate is mounted. The algorithm needs to be provided with a dataset of a single rotation from the laser scanner. To achieve a proper calibration result the scanner needs to be located in the middle of the hemisphere. By means of geometric formulas the algorithms determine the individual deviations of the placed laser scanner. In order to minimize errors, the algorithm solves the formulas in an iterative process. First, the calibration algorithm was

  15. Viability Prediction of Ricinus cummunis L. Seeds Using Multispectral Imaging

    DEFF Research Database (Denmark)

    Olesen, Merete Halkjær; Nikneshan, Pejman; Shrestha, Santosh

    2015-01-01

    The purpose of this study was to highlight the use of multispectral imaging in seed quality testing of castor seeds. Visually, 120 seeds were divided into three classes: yellow, grey and black seeds. Thereafter, images at 19 different wavelengths ranging from 375–970 nm were captured of all the s...

  16. Perancangan dan Pembuatan Alat Scanner 3D Menggunakan Sensor Kinect Xbox 360

    Directory of Open Access Journals (Sweden)

    Arif Armansyah

    2018-04-01

    Full Text Available Abstrak Scanner 3D adalah teknologi yang digunakan untuk memindai objek nyata untuk mendapatkan bentuk, ukuran dan fitur lainnya agar menghasilkan gambar yang sangat akurat. Dalam perancangan alat scanner 3D sebelumnya, yaitu scanner 3D menggunakan sensor ultrasonik, infra merah, dan line laser. Maka dapat disimpulkan terdapat beberapa kekurangan yaitu masih terbatasnya objek yang di scan serta hasil scan yang belum akurat karena hanya menghasilkan garis-garis yang membentuk objek. Pada penelitian ini, penulis membuat scanner 3D dengan hasil akurasi yang tinggi. Scanner 3D yang dibuat adalah menggunakan sensor Kinect xbox 360. Cara kerja dari kinect yaitu dengan menggabungkan antara beberapa kamera, Color Cimos (VNA38209015 kamera ini berfungsi membantu dalam pengenalan objek dan fitur deteksi lainnya, serta kamera IR CMOS (VCA379C7130, dan IR Projector (OG12 yaitu sebagai depth sensor atau sensor kedalaman yang merupakan sebuah proyektor infrared dan sebuah sensor monochrome CMOS yang bekerja secara bersama-sama untuk melihat ruangan atau area dalam bentuk 3D tanpa memperdulikan kondisi cahaya. Untuk mengolah serta menampilkan hasil dari objek yang sudah di scan menggunakan aplikasi KScan3D. Kemudian untuk koneksi antara PC dengan media penggerak menggunakan Bluetooth HC-06. Setelah dilakukan pengujian didapatkan model gambar 3D dengan dengan hasil akurasi yang cukup tinggi. Kata Kunci: Bluetooth HC-06, Infra Merah, Line Laser, Kinect, KScan3D, Scanner 3D, Ultrasonik Abstract Scanner 3D is the technology used to scan real objects to get the form, size and other features in order to produce pictures that are very accurate. In the design of the appliance scanner 3D previously, namely scanner 3D using the ultrasonic sensor, infrared and laser line. It can be concluded there are some disadvantages that is still limited objects in the scan and the scans are not accurate because only produces lines that formed the object. In this research, author

  17. Fast neutron radiography scanner for the detection of contraband in air cargo containers

    International Nuclear Information System (INIS)

    Eberhardt, J.E.; Rainey, S.; Stevens, R.J.; Sowerby, B.D.; Tickner, J.R.

    2005-01-01

    There is a growing need to rapidly scan bulk air cargo for contraband such as illicit drugs and explosives. The Commonwealth Science and Industrial Research Organisation (CSIRO) have been working with Australian Customs Service to develop a scanner capable of directly scanning airfreight containers in 1-2 minutes without unpacking. The scanner combines fast neutron and gamma-ray radiography to provide high-resolution images that include information on material composition. A full-scale prototype scanner has been successfully tested in the laboratory and a commercial-scale scanner is due to be installed at Brisbane airport in 2005

  18. Fast neutron radiography scanner for the detection of contraband in air cargo containers

    Energy Technology Data Exchange (ETDEWEB)

    Eberhardt, J.E. [CSIRO Minerals, Private Mail Bag 5, Menai, NSW 2234 (Australia); Rainey, S. [CSIRO Minerals, Private Mail Bag 5, Menai, NSW 2234 (Australia); Stevens, R.J. [CSIRO Minerals, Private Mail Bag 5, Menai, NSW 2234 (Australia); Sowerby, B.D. [CSIRO Minerals, Private Mail Bag 5, Menai, NSW 2234 (Australia)]. E-mail: brian.sowerby@csiro.au; Tickner, J.R. [CSIRO Minerals, Private Mail Bag 5, Menai, NSW 2234 (Australia)

    2005-08-01

    There is a growing need to rapidly scan bulk air cargo for contraband such as illicit drugs and explosives. The Commonwealth Science and Industrial Research Organisation (CSIRO) have been working with Australian Customs Service to develop a scanner capable of directly scanning airfreight containers in 1-2 minutes without unpacking. The scanner combines fast neutron and gamma-ray radiography to provide high-resolution images that include information on material composition. A full-scale prototype scanner has been successfully tested in the laboratory and a commercial-scale scanner is due to be installed at Brisbane airport in 2005.

  19. A survey of classical methods and new trends in pansharpening of multispectral images

    Directory of Open Access Journals (Sweden)

    Katsaggelos Aggelos

    2011-01-01

    Full Text Available Abstract There exist a number of satellites on different earth observation platforms, which provide multispectral images together with a panchromatic image, that is, an image containing reflectance data representative of a wide range of bands and wavelengths. Pansharpening is a pixel-level fusion technique used to increase the spatial resolution of the multispectral image while simultaneously preserving its spectral information. In this paper, we provide a review of the pan-sharpening methods proposed in the literature giving a clear classification of them and a description of their main characteristics. Finally, we analyze how the quality of the pansharpened images can be assessed both visually and quantitatively and examine the different quality measures proposed for that purpose.

  20. A fast ADC scanner for multiparameter nuclear physics experiments

    International Nuclear Information System (INIS)

    Midttun, G.; Ingebretsen, F.; Holt, K.; Skaali, B.

    1983-04-01

    A fast readout system for multiparameter experiments in nuclear physics is described. The central part of the CAMAC aquisition hardware is an ADC scanner module. The scanner incorporates a new arbitration logic and direct memory access for simultaneous transfer of singles and correlated data. Together with specially designed ADC interfaces the system can be set up for any configuration of singles and multiparameter events from 1 up to 15 ADC's in one crate

  1. A fast ADC scanner for multiparameter nuclear physics experiments

    International Nuclear Information System (INIS)

    Midttun, G.; Holt, K.; Ingebretsen, F.; Skaali, B.

    1983-01-01

    A fast readout system for multiparameter experiments in nuclear physics is described. The central part of the CAMAC aquisition hardware is an ADC scanner module. The scanner incorporates a new arbitration logic and direct memory access for simultaneous transfer of singles and correlated data. Together with specially designed ADC interfaces the system can be set up for any configurations of singles and multiparameter events from 1 up to 15 ADC's in one crate

  2. A Cross-Platform Smartphone Brain Scanner

    DEFF Research Database (Denmark)

    Larsen, Jakob Eg; Stopczynski, Arkadiusz; Stahlhut, Carsten

    We describe a smartphone brain scanner with a low-costwireless 14-channel Emotiv EEG neuroheadset interfacingwith multiple mobile devices. This personal informaticssystem enables minimally invasive and continuouscapturing of brain imaging data in natural settings. Thesystem applies an inverse...

  3. Robotic Prostate Biopsy in Closed MRI Scanner

    National Research Council Canada - National Science Library

    Fischer, Gregory

    2008-01-01

    .... This work enables prostate brachytherapy and biopsy procedures in standard high-field diagnostic MRI scanners through the development of a robotic needle placement device specifically designed...

  4. Development of high pressure pipe scanners

    International Nuclear Information System (INIS)

    Kim, Jae H.; Lee, Jae C.; Moon, Soon S.; Eom, Heung S.; Choi, Yu R.

    1998-12-01

    This report describes an automatic ultrasonic scanning system for pressure pipe welds, which was developed in this project using recent advanced technologies on mobile robot and computer. The system consists of two modules: a robot scanner module which navigates and manipulates scanning devices, and a data acquisition module which generates ultrasonic signal and processes the data from the scanner. The robot has 4 magnetic wheels and 2 -axis manipulator on which ultrasonic transducer attached. The wheeled robot can navigate curved surface such as outer wall of circular pipes. Magnetic wheels were optimally designed through magnetic field analysis. Free surface sensing and line tracking control algorithm were developed and implemented, and the control devices and software can be used in practical inspection works. We expect our system can contribute to reduction of inspection time, performance enhancement, and effective management of inspection results

  5. Airborne multispectral identification of individual cotton plants using consumer-grade cameras

    Science.gov (United States)

    Although multispectral remote sensing using consumer-grade cameras has successfully identified fields of small cotton plants, improvements to detection sensitivity are needed to identify individual or small clusters of plants. The imaging sensor of consumer-grade cameras are based on a Bayer patter...

  6. Unmixing chromophores in human skin with a 3D multispectral optoacoustic mesoscopy system

    Science.gov (United States)

    Schwarz, Mathias; Aguirre, Juan; Soliman, Dominik; Buehler, Andreas; Ntziachristos, Vasilis

    2016-03-01

    The absorption of visible light by human skin is governed by a number of natural chromophores: Eumelanin, pheomelanin, oxyhemoglobin, and deoxyhemoglobin are the major absorbers in the visible range in cutaneous tissue. Label-free quantification of these tissue chromophores is an important step of optoacoustic (photoacoustic) imaging towards clinical application, since it provides relevant information in diseases. In tumor cells, for instance, there are metabolic changes (Warburg effect) compared to healthy cells, leading to changes in oxygenation in the environment of tumors. In malignant melanoma changes in the absorption spectrum have been observed compared to the spectrum of nonmalignant nevi. So far, optoacoustic imaging has been applied to human skin mostly in single-wavelength mode, providing anatomical information but no functional information. In this work, we excited the tissue by a tunable laser source in the spectral range from 413-680 nm with a repetition rate of 50 Hz. The laser was operated in wavelengthsweep mode emitting consecutive pulses at various wavelengths that allowed for automatic co-registration of the multispectral datasets. The multispectral raster-scan optoacoustic mesoscopy (MSOM) system provides a lateral resolution of melanin, oxyhemoglobin, and deoxyhemoglobin, three-dimensional absorption maps of all three absorbers were calculated from the multispectral dataset.

  7. Ship-Iceberg Discrimination in Sentinel-2 Multispectral Imagery by Supervised Classification

    Directory of Open Access Journals (Sweden)

    Peder Heiselberg

    2017-11-01

    Full Text Available The European Space Agency Sentinel-2 satellites provide multispectral images with pixel sizes down to 10 m. This high resolution allows for fast and frequent detection, classification and discrimination of various objects in the sea, which is relevant in general and specifically for the vast Arctic environment. We analyze several sets of multispectral image data from Denmark and Greenland fall and winter, and describe a supervised search and classification algorithm based on physical parameters that successfully finds and classifies all objects in the sea with reflectance above a threshold. It discriminates between objects like ships, islands, wakes, and icebergs, ice floes, and clouds with accuracy better than 90%. Pan-sharpening the infrared bands leads to classification and discrimination of ice floes and clouds better than 95%. For complex images with abundant ice floes or clouds, however, the false alarm rate dominates for small non-sailing boats.

  8. Analysis of the Performance of a Laser Scanner for Predictive Automotive Applications

    Science.gov (United States)

    Zeisler, J.; Maas, H.-G.

    2015-08-01

    In this paper we evaluate the use of a laser scanner for future advanced driver assistance systems. We focus on the important task of predicting the target vehicle for longitudinal ego vehicle control. Our motivation is to decrease the reaction time of existing systems during cut-in maneuvers of other traffic participants. A state-of-the-art laser scanner, the Ibeo Scala B2 R , is presented, providing its sensing characteristics and the subsequent high level object data output. We evaluate the performance of the scanner towards object tracking with the help of a GPS real time kinematics system on a test track. Two designed scenarios show phases with constant distance and velocity as well as dynamic motion of the vehicles. We provide the results for the error in position and velocity of the scanner and furthermore, review our algorithm for target vehicle prediction. Finally we show the potential of the laser scanner with the estimated error, that leads to a decrease of up to 40% in reaction time with best conditions.

  9. Applying Neural Networks to Hyperspectral and Multispectral Field Data for Discrimination of Cruciferous Weeds in Winter Crops

    Directory of Open Access Journals (Sweden)

    Ana-Isabel de Castro

    2012-01-01

    Full Text Available In the context of detection of weeds in crops for site-specific weed control, on-ground spectral reflectance measurements are the first step to determine the potential of remote spectral data to classify weeds and crops. Field studies were conducted for four years at different locations in Spain. We aimed to distinguish cruciferous weeds in wheat and broad bean crops, using hyperspectral and multispectral readings in the visible and near-infrared spectrum. To identify differences in reflectance between cruciferous weeds, we applied three classification methods: stepwise discriminant (STEPDISC analysis and two neural networks, specifically, multilayer perceptron (MLP and radial basis function (RBF. Hyperspectral and multispectral signatures of cruciferous weeds, and wheat and broad bean crops can be classified using STEPDISC analysis, and MLP and RBF neural networks with different success, being the MLP model the most accurate with 100%, or higher than 98.1%, of classification performance for all the years. Classification accuracy from hyperspectral signatures was similar to that from multispectral and spectral indices, suggesting that little advantage would be obtained by using more expensive airborne hyperspectral imagery. Therefore, for next investigations, we recommend using multispectral remote imagery to explore whether they can potentially discriminate these weeds and crops.

  10. Aerial radiological measuring system program

    International Nuclear Information System (INIS)

    Doyle, J.F.; Boyns, P.K.

    1972-01-01

    The present ARMS aircraft has an effective survey time of four hours. Typical survey altitudes are 300 to 500 feet for terrain surveys and up to 20,000 feet for cloud tracks. A number of special airframe modifications have been made to accommodate the various sensor systems. The ARMS radiation measurement system consists of fourteen 4-inch diameter by 4-inch thick sodium iodide (NaI) detectors, a summing network for the detector signals, single and multichannel analyzers, analog computers, digital display and recording equipment, a doppler radar position computer, and strip chart recorders. Major subsystems include meteorology sensors, multispectral camera systems, and an infrared scanner for thermal mapping. Additional radiation detectors include an alpha spectrometer and a beta counter, used to count filter samples taken from a 150 cfm air sampler, which is a permanent part of the aircraft. A small lead shield houses a 1 / 2 -in. x 3-in. NaI crystal for beta and gamma counting of air filter samples. Several BF 3 neutron detectors are also available for neutron counting. The raw data from the gross gamma count and the gamma spectral measurements are permanently recorded on paper tape, and they must undergo reduction and analysis for final characterization of the radiological properties of the surveyed area. (U.S.)

  11. A new generation of PET scanners for small animal studies

    International Nuclear Information System (INIS)

    Hegyesi, G.; Imrek, J.; Kalinka, G.; Molnar, J.; Novak, D.; Valastyan, I.; Balkay, L.; Emri, M.; Kis, S.; Tron, L.

    2008-01-01

    Complete text of publication follows. Research on small animal PET scanners has been a hot topic in recent years. These devices are used in the preclinical phases of drug tests and during the development of new radiopharmaceuticals. They also provide a cost efficient way to test new materials, new design concepts and new technologies that later can be used to build more efficient human medical imaging devices. The development of a PET scanner requires expertise on different fields, therefore a consortium was formed that brought together Hungarian academic and industrial partners: the Nuclear Research Institute (which has experience in the development of nuclear detectors and data acquisition systems), the PET Center of the University of Debrecen (which has clinical experience in the application of nuclear imaging devices and background in image processing software), Mediso Ltd. (which has been developing, manufacturing, selling and servicing medical imaging devices since 1990) and other academic partners. This consortium has been working together since 2003: the knowledge base acquired during the development of our small animal PET scanners (miniPET-I and miniPET-II) is now being utilized to build a commercial multimodal human PET scanner. The operation of a PET scanner is based on the simultaneous detection ('coincidence') of two gamma photons originating from a positron annihilation. In traditional PET scanners coincidence is detected by a central unit during the measurement. In our system there is no such central module: all detected single gamma events are recorded (list mode data acquisition), and the list of events are processed using a computer cluster (built from PCs). The usage of independent detector modules and commercial components reduce both development and maintenance costs. Also, this mode of data acquisition is more suitable for development purposes, since once the data is collected and stored it can be used many times to test different signal

  12. A dedicated tool for PET scanner simulations using FLUKA

    International Nuclear Information System (INIS)

    Ortega, P.G.; Boehlen, T.T.; Cerutti, F.; Chin, M.P.W.; Ferrari, A.; Mancini, C.; Vlachoudis, V.; Mairani, A.; Sala, Paola R.

    2013-06-01

    Positron emission tomography (PET) is a well-established medical imaging technique. It is based on the detection of pairs of annihilation gamma rays from a beta+-emitting radionuclide, usually inoculated in the body via a biologically active molecule. Apart from its wide-spread use for clinical diagnosis, new applications are proposed. This includes notably the usage of PET for treatment monitoring of radiation therapy with protons and ions. PET is currently the only available technique for non-invasive monitoring of ion beam dose delivery, which was tested in several clinical pilot studies. For hadrontherapy, the distribution of positron emitters, produced by the ion beam, can be analyzed to verify the correct treatment delivery. The adaptation of previous PET scanners to new environments and the necessity of more precise diagnostics by better image quality triggered the development of new PET scanner designs. The use of Monte Carlo (MC) codes is essential in the early stages of the scanner design to simulate the transport of particles and nuclear interactions from therapeutic ion beams or radioisotopes and to predict radiation fields in tissues and radiation emerging from the patient. In particular, range verification using PET is based on the comparison of detected and simulated activity distributions. The accuracy of the MC code for the relevant physics processes is obviously essential for such applications. In this work we present new developments of the physics models with importance for PET monitoring and integrated tools for PET scanner simulations for FLUKA, a fully-integrated MC particle-transport code, which is widely used for an extended range of applications (accelerator shielding, detector and target design, calorimetry, activation, dosimetry, medical physics, radiobiology, ...). The developed tools include a PET scanner geometry builder and a dedicated scoring routine for coincident event determination. The geometry builder allows the efficient

  13. Spot-5 multispectral image for 60-75 days of rice mapping

    International Nuclear Information System (INIS)

    Ramli, Mohd Amiruddin; Shariff, Abdul Rashid Mohamed; Bejo, Siti Khairunniza

    2014-01-01

    The objective of this study is to investigate the potential application of Spot-5 multispectral satellite data in monitoring rice cultivation areas in IADA (Integrated Agriculture Development Area) located at Kerian District, Perak Malaysia. Information of the rice cultivation areas is a global economic and environmental significance. Multi-spectral images acquired at high spatial resolution are an important tool, especially in agricultural applications. This paper addresses the relationship between normalize difference vegetation index (NDVI) and ancillary data acquired from Farmers Organization Authority (PPK) for 217 farmer's field in IADA Kerian. The results indicated that NDVI range 0.62 – 0.75 has a strong positive relationship with the ground survey area estimation with (r = 0.85; p <0.01) (r 2 = 0.722). The r 2 value of 0.722 indicated a statistically significant linear relationship between the rice area estimate using NDVI range 0.62 – 0.75 and on the ground surveyed data for 217 farmers' fields. The equation of unstandardized distribution can be described as Ŷ=0.0197+0.852x. The equation for standardized regression formula for this distribution is Ŷ= 0.850x. Thus, the results indicate that 60-75 days of rice area can be estimated from the following equation Ŷ=0.197+0.852x, where Ŷ is the predicted rice area and x is area calculated using NDVI range 0.62-0.75 in IADA Kerian Perak Malaysia. The results appear promising and rice mapping operations using SPOT-5 multispectral image data can be foreseen

  14. Large angle and high linearity two-dimensional laser scanner based on voice coil actuators

    Science.gov (United States)

    Wu, Xin; Chen, Sihai; Chen, Wei; Yang, Minghui; Fu, Wen

    2011-10-01

    A large angle and high linearity two-dimensional laser scanner with an in-house ingenious deflection angle detecting system is developed based on voice coil actuators direct driving mechanism. The specially designed voice coil actuators make the steering mirror moving at a sufficiently large angle. Frequency sweep method based on virtual instruments is employed to achieve the natural frequency of the laser scanner. The response shows that the performance of the laser scanner is limited by the mechanical resonances. The closed-loop controller based on mathematical model is used to reduce the oscillation of the laser scanner at resonance frequency. To design a qualified controller, the model of the laser scanner is set up. The transfer function of the model is identified with MATLAB according to the tested data. After introducing of the controller, the nonlinearity decreases from 13.75% to 2.67% at 50 Hz. The laser scanner also has other advantages such as large deflection mirror, small mechanical structure, and high scanning speed.

  15. Panoramic, Macro and Micro Multispectral Imaging: An Affordable System for Mapping Pigments on Artworks

    Directory of Open Access Journals (Sweden)

    Antonino Cosentino

    2015-07-01

    Full Text Available Multispectral imaging systems are used in art examinations to map and identify pigments, binders and areas of retouching. A monochromatic camera is combined with an appropriate wavelength selection system and acquires a variable number of spectral images of a scene. These images are then stacked into a reflectance imaging cube to reconstruct reflectance spectra from each of the images’ pixels. This paper presents an affordable multispectral imaging system composed of a monochromatic CCD camera and a set of only 12 interference filters for mapping pigments on works of art and for the tentative identification of such pigments. This work demonstrates the versatility of this set-up, a versatility enabling it to be applied to different tasks, involving examination and documentation of objects of varying size. Use of this multispectral camera for both panoramic and macro photography is discussed, together with the possibilities facilitated from the coupling of the system to a stereomicroscope and a compound microscope. This system is of particular interest for the cultural heritage sector because of its hardware simplicity and acquisition speed, as well as its lightness and small dimensions.

  16. Multispectral mid-infrared imaging using frequency upconversion

    DEFF Research Database (Denmark)

    Sanders, Nicolai Højer; Dam, Jeppe Seidelin; Jensen, Ole Bjarlin

    2013-01-01

    It has recently been shown that it is possible to upconvert infrared images to the near infrared region with high quantum efficiency and low noise by three-wave mixing with a laser field [1]. If the mixing laser is single-frequency, the upconverted image is simply a band-pass filtered version...... parameter, allowing for fast tuning and hence potentially fast image acquisition, paving the way for upconversion based real time multispectral imaging. In the present realization the upconversion module consists of an external cavity tapered diode laser in a Littrow configuration with a computer controlled...

  17. Does the Use of Body Scanners Discriminate Overweight Flight Passengers? The Effect of Body Scanners on Body Image

    Directory of Open Access Journals (Sweden)

    Magdalena Laib

    2016-06-01

    Full Text Available Whereas the introduction of body scanners at airports has been accompanied by critical voices raising concerns that body scanners might have a negative impact on different minority groups, it has not been investigated thus far whether they might also have negative impacts on the average flight passenger and if the provision of adequate information might attenuate such negative impacts. Using a pre/post-design the current study examines the effect of a body scan in a controlled laboratory setting on the explicit and implicit body image of normal-weight and overweight people as assessed by questionnaires and an Implicit Association Test. Half of the sample received an information sheet concerning body scanners before they were scanned. While there was a negative impact of the body scan on the implicit body image of overweight participants, there was a positive impact on their explicit body image. The negative effect of the body scan was unaffected by receiving information. This study demonstrates that body scans do not only have negative effects on certain minority groups but potentially on a large proportion of the general public which suggests a critical reconsideration of the control procedures at airports, the training of the airport staff who is in charge of these procedures and the information flight passengers get about these procedures.

  18. Unsteady pressures on a blunt trailing edge measured with an embedded pressure scanner

    Science.gov (United States)

    Naughton, Jonathan; Nikoueeyan, Pourya; Hind, Michael; Strike, John; Dahland, Matz; Keeter, Steven

    2017-11-01

    Development of direct-mount pressure scanners can decrease the pneumatic tubing length required to connect the measurement ports to the scanner manifold resulting in improved dynamic range for unsteady pressure measurements. In this work, the performance of a direct-mount pressure scanner for time-resolved pressure measurement is demonstrated in a well-established flow; the pressure fluctuations near the base of flat plate is considered. The additive manufactured model is instrumented with a pressure scanner and flush-mounted high-speed pressure transducers. The configuration of the ports on the model allows for side-by-side comparison of the pressures measured via embedded pneumatic tubing routed to a pressure scanner with that measured by high-speed transducers. Prior to testing, the dynamic response of each embedded pressure port is dynamically calibrated via an in-situ calibration technique. Pressure data is then acquired for fixed angle-of-attack and different dynamic pitching conditions. The dynamic range of the measurements acquired via direct-mount scanner will be compared to those acquired by the high speed transducers for both static and dynamic pitching configurations. The uncertainties associated with Weiner deconvolution are also quantified for the measurements.

  19. The design of the detector and collimators for a hybrid scanner

    International Nuclear Information System (INIS)

    Vauramo, E.; Virjo, A.

    1977-01-01

    The hybrid scanner is a scanning device in which a long crystal with two or more photomultiplier (PM) tubes acts as a gamma camera along the crystal axis; the device acts as a linear scanner in a direction perpendicular to the crystal axis. A detailed analysis of the intrinsic resolution and uniformity is given for a two-PM-tube hybrid scanner (with one PM tube at each end) and the expressions derived should help the designer to choose the best crystal system. Collimation theory is discussed for the general hybrid scanner. Expressions and graphs are given to help in the design of a collimator with the best balance between the conflicting requirements of resolution, sensitivity, depth independence and freedom from artifacts (collimator holes may be seen in the image at high energy). Examples of practical collimators are given for energies of 80 to 140, 364, 511, 662 and 840 keV. (author)

  20. Multispectral fluorescence image algorithms for detection of frass on mature tomatoes

    Science.gov (United States)

    A multispectral algorithm derived from hyperspectral line-scan fluorescence imaging under violet LED excitation was developed for the detection of frass contamination on mature tomatoes. The algorithm utilized the fluorescence intensities at five wavebands, 515 nm, 640 nm, 664 nm, 690 nm, and 724 nm...

  1. Digital image processing techniques in archaeology

    Digital Repository Service at National Institute of Oceanography (India)

    Santanam, K.; Vaithiyanathan, R.; Tripati, S.

    Digital image processing involves the manipulation and interpretation of digital images with the aid of a computer. This form of remote sensing actually began in the 1960's with a limited number of researchers analysing multispectral scanner data...

  2. Accuracy and efficiency of full-arch digitalization and 3D printing: A comparison between desktop model scanners, an intraoral scanner, a CBCT model scan, and stereolithographic 3D printing.

    Science.gov (United States)

    Wesemann, Christian; Muallah, Jonas; Mah, James; Bumann, Axel

    2017-01-01

    The primary objective of this study was to compare the accuracy and time efficiency of an indirect and direct digitalization workflow with that of a three-dimensional (3D) printer in order to identify the most suitable method for orthodontic use. A master model was measured with a coordinate measuring instrument. The distances measured were the intercanine width, the intermolar width, and the dental arch length. Sixty-four scans were taken with each of the desktop scanners R900 and R700 (3Shape), the intraoral scanner TRIOS Color Pod (3Shape), and the Promax 3D Mid cone beam computed tomography (CBCT) unit (Planmeca). All scans were measured with measuring software. One scan was selected and printed 37 times on the D35 stereolithographic 3D printer (Innovation MediTech). The printed models were measured again using the coordinate measuring instrument. The most accurate results were obtained by the R900. The R700 and the TRIOS intraoral scanner showed comparable results. CBCT-3D-rendering with the Promax 3D Mid CBCT unit revealed significantly higher accuracy with regard to dental casts than dental impressions. 3D printing offered a significantly higher level of deviation than digitalization with desktop scanners or an intraoral scanner. The chairside time required for digital impressions was 27% longer than for conventional impressions. Conventional impressions, model casting, and optional digitization with desktop scanners remains the recommended workflow process. For orthodontic demands, intraoral scanners are a useful alternative for full-arch scans. For prosthodontic use, the scanning scope should be less than one quadrant and three additional teeth.

  3. Diagnosing hypoxia in murine models of rheumatoid arthritis from reflectance multispectral images

    Science.gov (United States)

    Glinton, Sophie; Naylor, Amy J.; Claridge, Ela

    2017-07-01

    Spectra computed from multispectral images of murine models of Rheumatoid Arthritis show a characteristic decrease in reflectance within the 600-800nm region which is indicative of the reduction in blood oxygenation and is consistent with hypoxia.

  4. Radiometric Cross-Calibration of GF-4 in Multispectral Bands

    Directory of Open Access Journals (Sweden)

    Aixia Yang

    2017-03-01

    Full Text Available The GaoFen-4 (GF-4, launched at the end of December 2015, is China’s first high-resolution geostationary optical satellite. A panchromatic and multispectral sensor (PMS is onboard the GF-4 satellite. Unfortunately, the GF-4 has no onboard calibration assembly, so on-orbit radiometric calibration is required. Like the charge-coupled device (CCD onboard HuanJing-1 (HJ or the wide field of view sensor (WFV onboard GaoFen-1 (GF-1, GF-4 also has a wide field of view, which provides challenges for cross-calibration with narrow field of view sensors, like the Landsat series. A new technique has been developed and used to calibrate HJ-1/CCD and GF-1/WFV, which is verified viable. The technique has three key steps: (1 calculate the surface using the bi-directional reflectance distribution function (BRDF characterization of a site, taking advantage of its uniform surface material and natural topographic variation using Landsat Enhanced Thematic Mapper Plus (ETM+/Operational Land Imager (OLI imagery and digital elevation model (DEM products; (2 calculate the radiance at the top-of-the atmosphere (TOA with the simulated surface reflectance using the atmosphere radiant transfer model; and (3 fit the calibration coefficients with the TOA radiance and corresponding Digital Number (DN values of the image. This study attempts to demonstrate the technique is also feasible to calibrate GF-4 multispectral bands. After fitting the calibration coefficients using the technique, extensive validation is conducted by cross-validation using the image pairs of GF-4/PMS and Landsat-8/OLI with similar transit times and close view zenith. The validation result indicates a higher accuracy and frequency than that given by the China Centre for Resources Satellite Data and Application (CRESDA using vicarious calibration. The study shows that the new technique is also quite feasible for GF-4 multispectral bands as a routine long-term procedure.

  5. Detector Position Estimation for PET Scanners.

    Science.gov (United States)

    Pierce, Larry; Miyaoka, Robert; Lewellen, Tom; Alessio, Adam; Kinahan, Paul

    2012-06-11

    Physical positioning of scintillation crystal detector blocks in Positron Emission Tomography (PET) scanners is not always exact. We test a proof of concept methodology for the determination of the six degrees of freedom for detector block positioning errors by utilizing a rotating point source over stepped axial intervals. To test our method, we created computer simulations of seven Micro Crystal Element Scanner (MiCES) PET systems with randomized positioning errors. The computer simulations show that our positioning algorithm can estimate the positions of the block detectors to an average of one-seventh of the crystal pitch tangentially, and one-third of the crystal pitch axially. Virtual acquisitions of a point source grid and a distributed phantom show that our algorithm improves both the quantitative and qualitative accuracy of the reconstructed objects. We believe this estimation algorithm is a practical and accurate method for determining the spatial positions of scintillation detector blocks.

  6. Detector position estimation for PET scanners

    International Nuclear Information System (INIS)

    Pierce, Larry; Miyaoka, Robert; Lewellen, Tom; Alessio, Adam; Kinahan, Paul

    2012-01-01

    Physical positioning of scintillation crystal detector blocks in Positron Emission Tomography (PET) scanners is not always exact. We test a proof of concept methodology for the determination of the six degrees of freedom for detector block positioning errors by utilizing a rotating point source over stepped axial intervals. To test our method, we created computer simulations of seven Micro Crystal Element Scanner (MiCES) PET systems with randomized positioning errors. The computer simulations show that our positioning algorithm can estimate the positions of the block detectors to an average of one-seventh of the crystal pitch tangentially, and one-third of the crystal pitch axially. Virtual acquisitions of a point source grid and a distributed phantom show that our algorithm improves both the quantitative and qualitative accuracy of the reconstructed objects. We believe this estimation algorithm is a practical and accurate method for determining the spatial positions of scintillation detector blocks.

  7. AN AUTOMATIC PROCEDURE FOR COMBINING DIGITAL IMAGES AND LASER SCANNER DATA

    Directory of Open Access Journals (Sweden)

    W. Moussa

    2012-07-01

    Full Text Available Besides improving both the geometry and the visual quality of the model, the integration of close-range photogrammetry and terrestrial laser scanning techniques directs at filling gaps in laser scanner point clouds to avoid modeling errors, reconstructing more details in higher resolution and recovering simple structures with less geometric details. Thus, within this paper a flexible approach for the automatic combination of digital images and laser scanner data is presented. Our approach comprises two methods for data fusion. The first method starts by a marker-free registration of digital images based on a point-based environment model (PEM of a scene which stores the 3D laser scanner point clouds associated with intensity and RGB values. The PEM allows the extraction of accurate control information for the direct computation of absolute camera orientations with redundant information by means of accurate space resection methods. In order to use the computed relations between the digital images and the laser scanner data, an extended Helmert (seven-parameter transformation is introduced and its parameters are estimated. Precedent to that, in the second method, the local relative orientation parameters of the camera images are calculated by means of an optimized Structure and Motion (SaM reconstruction method. Then, using the determined transformation parameters results in having absolute oriented images in relation to the laser scanner data. With the resulting absolute orientations we have employed robust dense image reconstruction algorithms to create oriented dense image point clouds, which are automatically combined with the laser scanner data to form a complete detailed representation of a scene. Examples of different data sets are shown and experimental results demonstrate the effectiveness of the presented procedures.

  8. Propulsion controlled aircraft computer

    Science.gov (United States)

    Cogan, Bruce R. (Inventor)

    2010-01-01

    A low-cost, easily retrofit Propulsion Controlled Aircraft (PCA) system for use on a wide range of commercial and military aircraft consists of an propulsion controlled aircraft computer that reads in aircraft data including aircraft state, pilot commands and other related data, calculates aircraft throttle position for a given maneuver commanded by the pilot, and then displays both current and calculated throttle position on a cockpit display to show the pilot where to move throttles to achieve the commanded maneuver, or is automatically sent digitally to command the engines directly.

  9. Ultra-High-Resolution Computed Tomography of the Lung: Image Quality of a Prototype Scanner

    OpenAIRE

    Kakinuma, Ryutaro; Moriyama, Noriyuki; Muramatsu, Yukio; Gomi, Shiho; Suzuki, Masahiro; Nagasawa, Hirobumi; Kusumoto, Masahiko; Aso, Tomohiko; Muramatsu, Yoshihisa; Tsuchida, Takaaki; Tsuta, Koji; Maeshima, Akiko Miyagi; Tochigi, Naobumi; Watanabe, Shun-ichi; Sugihara, Naoki

    2015-01-01

    Purpose: The image noise and image quality of a prototype ultra-high-resolution computed tomography (U-HRCT) scanner was evaluated and compared with those of conventional high-resolution CT (C-HRCT) scanners. Materials and Methods: This study was approved by the institutional review board. A U-HRCT scanner prototype with 0.25 mm × 4 rows and operating at 120 mAs was used. The C-HRCT images were obtained using a 0.5 mm × 16 or 0.5 mm × 64 detector-row CT scanner operating at 150 mAs. Images fr...

  10. Radiation safety concerns and diagnostic reference levels for computed tomography scanners in Tamil Nadu

    International Nuclear Information System (INIS)

    Livingstone, Roshan S.; Dinakaran, Paul M.

    2011-01-01

    Radiation safety in computed tomography (CT) scanners is of concern due its widespread use in the field of radiological imaging. This study intends to evaluate radiation doses imparted to patients undergoing thorax, abdomen and pelvic CT examinations and formulate regional diagnostic reference levels (DRL) in Tamil Nadu, South India. In-site CT dose measurement was performed in 127 CT scanners in Tamil Nadu for a period of 2 years as a part of the Atomic Energy Regulatory Board (AERB)-funded project. Out of the 127 CT scanners,13 were conventional; 53 single-slice helical scanners (SSHS); 44 multislice CT (MSCT) scanners; and 17 refurbished scanners. CT dose index (CTDI) was measured using a 32-cm polymethyl methacrylate (PMMA)-body phantom in each CT scanner. Dose length product (DLP) for different anatomical regions was generated using CTDI values. The regional DRLs for thorax, abdomen and pelvis examinations were 557, 521 and 294 mGy cm, respectively. The mean effective dose was estimated using the DLP values and was found to be 8.04, 6.69 and 4.79 mSv for thorax, abdomen and pelvic CT examinations, respectively. The establishment of DRLs in this study is the first step towards optimization of CT doses in the Indian context. (author)

  11. Calibration of passive remote observing optical and microwave instrumentation; Proceedings of the Meeting, Orlando, FL, Apr. 3-5, 1991

    Science.gov (United States)

    Guenther, Bruce W.

    Various papers on the calibration of passive remote observing optical and microwave instrumentation are presented. Individual topics addressed include: on-board calibration device for a wide field-of-view instrument, calibration for the medium-resolution imaging spectrometer, cryogenic radiometers and intensity-stabilized lasers for EOS radiometric calibrations, radiometric stability of the Shuttle-borne solar backscatter ultraviolet spectrometer, ratioing radiometer for use with a solar diffuser, requirements of a solar diffuser and measurements of some candidate materials, reflectance stability analysis of Spectralon diffuse calibration panels, stray light effects on calibrations using a solar diffuser, radiometric calibration of SPOT 23 HRVs, surface and aerosol models for use in radiative transfer codes. Also addressed are: calibrated intercepts for solar radiometers used in remote sensor calibration, radiometric calibration of an airborne multispectral scanner, in-flight calibration of a helicopter-mounted Daedalus multispectral scanner, technique for improving the calibration of large-area sphere sources, remote colorimetry and its applications, spatial sampling errors for a satellite-borne scanning radiometer, calibration of EOS multispectral imaging sensors and solar irradiance variability. (For individual items see A93-23576 to A93-23603)

  12. Indirect identification and compensation of lateral scanner resonances in atomic force microscopes

    International Nuclear Information System (INIS)

    Burns, D J; Youcef-Toumi, K; Fantner, G E

    2011-01-01

    Improving the imaging speed of atomic force microscopy (AFM) requires accurate nanopositioning at high speeds. However, high speed operation excites resonances in the AFM's mechanical scanner that can distort the image, and therefore typical users of commercial AFMs elect to operate microscopes at speeds below which scanner resonances are observed. Although traditional robust feedforward controllers and input shaping have proven effective at minimizing the influence of scanner distortions, the lack of direct measurement and use of model-based controllers have required disassembling the microscope to access lateral scanner motion with external sensors in order to perform a full system identification experiment, which places excessive demands on routine microscope operators. Further, since the lightly damped instrument dynamics often change from experiment to experiment, model-based controllers designed from offline system identification experiments must trade off high speed performance for robustness to modeling errors. This work represents a new way to automatically characterize the lateral scanner dynamics without addition of lateral sensors, and shape the commanded input signals in such a way that disturbing dynamics are not excited. Scanner coupling between the lateral and out-of-plane directions is exploited and used to build a minimal model of the scanner that is also sufficient to describe the nature of the distorting resonances. This model informs the design of an online input shaper used to suppress spectral components of the high speed command signals. The method presented is distinct from alternative approaches in that neither an information-complete system identification experiment nor microscope modification are required. Because the system identification is performed online immediately before imaging, no tradeoff of performance is required. This approach has enabled an increase in the scan rates of unmodified commercial AFMs from 1-4 lines s -1 to over

  13. Inter-operator and inter-device agreement and reliability of the SEM Scanner.

    Science.gov (United States)

    Clendenin, Marta; Jaradeh, Kindah; Shamirian, Anasheh; Rhodes, Shannon L

    2015-02-01

    The SEM Scanner is a medical device designed for use by healthcare providers as part of pressure ulcer prevention programs. The objective of this study was to evaluate the inter-rater and inter-device agreement and reliability of the SEM Scanner. Thirty-one (31) volunteers free of pressure ulcers or broken skin at the sternum, sacrum, and heels were assessed with the SEM Scanner. Each of three operators utilized each of three devices to collect readings from four anatomical sites (sternum, sacrum, left and right heels) on each subject for a total of 108 readings per subject collected over approximately 30 min. For each combination of operator-device-anatomical site, three SEM readings were collected. Inter-operator and inter-device agreement and reliability were estimated. Over the course of this study, more than 3000 SEM Scanner readings were collected. Agreement between operators was good with mean differences ranging from -0.01 to 0.11. Inter-operator and inter-device reliability exceeded 0.80 at all anatomical sites assessed. The results of this study demonstrate the high reliability and good agreement of the SEM Scanner across different operators and different devices. Given the limitations of current methods to prevent and detect pressure ulcers, the SEM Scanner shows promise as an objective, reliable tool for assessing the presence or absence of pressure-induced tissue damage such as pressure ulcers. Copyright © 2015 Bruin Biometrics, LLC. Published by Elsevier Ltd.. All rights reserved.

  14. A double-bent planar leaf flexure guide for a nano-scanner: experimental report

    International Nuclear Information System (INIS)

    Jeon, Jeong-Woo; Kim, Jong-Moon; Lee, Young-Hyoung; Lee, Dong-Yeon

    2014-01-01

    We describe an experimental study on the double-bent leaf flexure-guided nano-scanner introduced in a previous paper [J. Korean Phy. Soc. 57, 1581 (2010)]. The optimally-designed nanoscanner was fabricated. Its performances were verified using a finite element analysis (FEA). The nano-scanner is actuated by a voice coil motor. Its characteristics were measured with a laser interferometer. The first resonant frequency is calculated as 17.1 Hz. The performances of the nano-scanner, including sine tracking capability, a multi-step response, and range of travel check were evaluated using various experimental procedures. Test results reveal that the scanner traveled over a 4.0 mm range and had good nano-precision (4 nm).

  15. A sweep plate emittance scanner for high-power CW ion beams

    International Nuclear Information System (INIS)

    Debiak, T.W.; Ng, Y.; Sredniawski, J.; Stasi, W.

    1996-01-01

    Sweep plate scanners are preferred for emittance measurement due to their versatility, simplicity, and precision. At the Advanced Technology and Development Center of Northrop Grumman, we have routinely used these devices for characterization of injector beams with less than 20 W/cm 2 average power density. To characterize higher power beams, like those required for production of tritium or for radioactive waste transmutation, the scanner pod and data collection algorithm must be redesigned due to the possibility of melting the scanner's protective front face or distorting the precision entrance knife edges. Among the methods we have used to mitigate these effects, one consists of drastically reducing the amount of time required for data collection. In this method, the emittance scanner pod traverses the beam in two passes, each requiring less than 0.5 second. In the first pass, the phase space limits of the beam are determined. In the second pass, data is collected primarily within the phase space region limits determined in the first pass. In this way, enough points are collected to assure that the precision of the measurement is high, even though the data collection time for each scan is less than 0.5 second. This paper will describe the layout of the scanner components, the data collection electronics and algorithm, and the data analysis. (author)

  16. Important considerations for radiochromic film dosimetry with flatbed CCD scanners and EBT GAFCHROMIC[reg] film

    International Nuclear Information System (INIS)

    Lynch, Bart D.; Kozelka, Jakub; Ranade, Manisha K.; Li, Jonathan G.; Simon, William E.; Dempsey, James F.

    2006-01-01

    In this study, we present three significant artifacts that have the potential to negatively impact the accuracy and precision of film dosimetry measurements made using GAFCHROMIC[reg] EBT radiochromic film when read out with CCD flatbed scanners. Films were scanned using three commonly employed instruments: a Macbeth TD932 spot densitometer, an Epson Expression 1680 CCD array scanner, and a Microtek ScanMaker i900 CCD array scanner. For the two scanners we assessed the variation in optical density (OD) of GAFCHROMIC EBT film with scanning bed position, angular rotation of the film with respect to the scan line direction, and temperature inside the scanner due to repeated scanning. Scanning uniform radiochromic films demonstrated a distinct bowing effect in profiles in the direction of the CCD array with a nonuniformity of up to 17%. Profiles along a direction orthogonal to the CCD array demonstrated a 7% variation. A strong angular dependence was found in measurements made with the flatbed scanners; the effect could not be reproduced with the spot densitometer. An IMRT quality assurance film was scanned twice rotating the film 90 deg. between the scans. For films scanned on the Epson scanner, up to 12% variation was observed in unirradiated EBT films rotated between 0 deg. and 90 deg. , which decreased to approximately 8% for EBT films irradiated to 300 cGy. Variations of up to 80% were observed for films scanned with the Microtek scanner. The scanners were found to significantly increase the film temperature with repeated scanning. Film temperature between 18 and 33 deg. C caused OD changes of approximately 7%. Considering these effects, we recommend adherence to a strict scanning protocol that includes: maintaining the orientation of films scanned on flatbed scanners, limiting scanning to the central portion of the scanner bed, and limiting the number of consecutive scans to minimize changes in OD caused by film heating

  17. Distant Determination of Bilirubin Distribution in Skin by Multi-Spectral Imaging

    Science.gov (United States)

    Saknite, I.; Jakovels, D.; Spigulis, J.

    2011-01-01

    For mapping the bilirubin distribution in bruised skin the multi-spectral imaging technique was employed, which made it possible to observe temporal changes of the bilirubin content in skin photo-types II and III. The obtained results confirm the clinical potential of this technique for skin bilirubin diagnostics.

  18. Scanner and irradiation: optimization of protocols

    International Nuclear Information System (INIS)

    Duchemin, J.; Martine-Rollet, B.; Lienart, S.; Mobailly, M.; Florin, J.P.; Beregi, J.P.; Puech, N.

    2006-01-01

    The irradiation of the patient or the personnel increased with the arrival of the multi-detector scanners. The objective of this work is to realize a didactic poster to inform and make sensitive on the irradiation with scan so that to propose solutions of protection. (N.C.)

  19. Small transport aircraft technology

    Science.gov (United States)

    Williams, L. J.

    1983-01-01

    Information on commuter airline trends and aircraft developments is provided to upgrade the preliminary findings of a NASA-formed small transport aircraft technology (STAT) team, established to determine whether the agency's research and development programs could help commuter aircraft manufacturers solve technical problems related to passenger acceptance and use of 19- to 50-passenger aircraft. The results and conclusions of the full set of completed STAT studies are presented. These studies were performed by five airplane manufacturers, five engine manufacturers, and two propeller manufacturers. Those portions of NASA's overall aeronautics research and development programs which are applicable to commuter aircraft design are summarized. Areas of technology that might beneficially be expanded or initiated to aid the US commuter aircraft manufacturers in the evolution of improved aircraft for the market are suggested.

  20. Linac beam core modeling from wire-scanner data

    International Nuclear Information System (INIS)

    Law, A.G.

    1977-08-01

    This study introduces mathematical modeling of accelerator beams from data collected by wire scanners. Details about a beam core D(x,x',y,y') are examined in several situations: (a) for a discretization of the projection into xy-space, a maximum-entropy solution and a minimum-norm solution are developed and discussed, (b) for undiscretized xy-subspace, a two-dimensional Gaussian approximation D(x,.,y,.) = a exp [α(x-x 0 ) 2 + β(x-x 0 )(y-y 0 ) + γ(y-y 0 ) 2 ] is obtained by least squares, and (c) for four-dimensional space, the fit of a single Gaussian to data from a succession of wire scanners is investigated

  1. Isocount scintillation scanner with preset statistical data reliability

    International Nuclear Information System (INIS)

    Ikebe, J.; Yamaguchi, H.; Nawa, O.A.

    1975-01-01

    A scintillation detector scans an object such as a live body along horizontal straight scanning lines in such a manner that the scintillation detector is stopped at a scanning point during the time interval T required for counting a predetermined number of N pulses. The rate R/sub N/ = N/T is then calculated and the output signal pulses the number of which represents the rate R or the corresponding output signal is used as the recording signal for forming the scintigram. In contrast to the usual scanner, the isocount scanner scans an object stepwise in order to gather data with statistically uniform reliability

  2. A novel multispectral glacier mapping method and its performance in Greenland

    Science.gov (United States)

    Citterio, M.; Fausto, R. S.; Ahlstrom, A. P.; Andersen, S. B.

    2014-12-01

    Multispectral land surface classification methods are widely used for mapping glacier outlines. Significant post-classification manual editing is typically required, and mapping glacier outlines over larger regions remains a rather labour intensive task. In this contribution we introduce a novel method for mapping glacier outlines from multispectral satellite imagery, requiring only minor manual editing.Over the last decade GLIMS (Global Land Ice Measurements from Space) improved the availability of glacier outlines, and in 2012 the Randolph Glacier Inventory (RGI) attained global coverage by compiling existing and new data sources in the wake of the Fifth Assessment Report of the Intergovernmental Panel on Climate Change (IPCC AR5). With the launch of Landsat 8 in 2013 and the upcoming ESA (European Space Agency) Sentinel 2 missions, the availability of multispectral imagery may grow faster than our ability to process it into timely and reliable glacier outline products. Improved automatic classification methods would enable a full exploitation of these new data sources.We outline the theoretical basis of the proposed classification algorithm, provide a step by step walk-through from raw imagery to finished ice cover grids and vector glacier outlines, and evaluate the performance of the new method in mapping the outlines of glaciers, ice caps and the Greenland Ice Sheet from Landsat 8 OLI imagery. The classification output is compared against manually digitized ice margin positions, the RGI vectors, and the PROMICE (Programme for Monitoring of the Greenland Ice Sheet) aerophotogrammetric map of Greenland ice masses over a sector of the Disko Island surge cluster in West Greenland, the Qassimiut ice sheet lobe in South Greenland, and the A.P. Olsen ice cap in NE Greenland.

  3. Methods and apparatus for laser beam scanners with different actuating mechanisms

    Science.gov (United States)

    Chen, Si-hai; Xiang, Si-hua; Wu, Xin; Dong, Shan; Xiao, Ding; Zheng, Xia-wei

    2009-07-01

    In this paper, 3 types of laser beam scanner are introduced. One is transmissive beam scanner, which is composed of convex and concave microlens arrays (MLAs). By moving the concave lens in the plane vertical to the optical axis, the incident beam can be deflected in two dimensions. Those two kinds of MLAs are fabricated by thermal reflow and replication process. A set of mechanical scanner frame is fabricated with the two MLAs assembling in it. The testing result shown that the beam deflection angles are 9.5° and 9.6°, in the 2 dimension(2D) with the scanning frequency of 2 HZ and 8 HZ, respectively. The second type of laser beam scanner is actuated by voice coil actuators (VCAs). Based on ANSOFT MAXWELL software, we have designed VCAs with small size and large force which have optimized properties. The model of VCAs is built using AutoCAD and is analyzed by Ansoft maxwell. According to the simulation results, high performance VCAs are fabricated and tested. The result is that the force of the VCAs is 6.39N/A, and the displacement is +/-2.5mm. A set up of beam scanner is fabricated and actuated by the designed VCAs. The testing result shown that the two dimensional scanning angle is 15° and 10° respectively at the frequency of 60HZ. The two dimensional scanning angle is 8.3° and 6° respectively at the frequency of 100HZ. The third type of scanner is actuated by amplified piezoelectric actuators (APAs). The scanning mirror is actuated by the piezoelectric (PZ) actuators with the scanning frequency of 700HZ, 250HZ and 87HZ respectively. The optical scanning angle is +/-0.5° at the three frequencies.

  4. Registration of 3D and Multispectral Data for the Study of Cultural Heritage Surfaces

    Science.gov (United States)

    Chane, Camille Simon; Schütze, Rainer; Boochs, Frank; Marzani, Franck S.

    2013-01-01

    We present a technique for the multi-sensor registration of featureless datasets based on the photogrammetric tracking of the acquisition systems in use. This method is developed for the in situ study of cultural heritage objects and is tested by digitizing a small canvas successively with a 3D digitization system and a multispectral camera while simultaneously tracking the acquisition systems with four cameras and using a cubic target frame with a side length of 500 mm. The achieved tracking accuracy is better than 0.03 mm spatially and 0.150 mrad angularly. This allows us to seamlessly register the 3D acquisitions and to project the multispectral acquisitions on the 3D model. PMID:23322103

  5. High-picture quality industrial CT scanner

    International Nuclear Information System (INIS)

    Shoji, Takao; Nishide, Akihiko; Fujii, Masashi.

    1989-01-01

    Industrial X-ray-CT-scanners, which provide cross-sectional images of a tested sample without destroying it, are attracting attention as a new nondestructive inspection device. In 1982, Toshiba commenced the development of industrial CT scanners, and introduced the 'TOSCANER' -3000 and-4000 series. Now, the state of the art 'TOSCANER'-20000 series of CT systems has been developed incorporating the latest computer tomography and image processing technology, such as the T9506 image processor. One of the advantages of this system is its applicability to a wide range of X-ray energy . The 'TOSCANER'-20000 series can be utilized for inspecting castings and other materials with relatively low-transparency to X-rays, as well as ceramics, composite materials and other materials with high X-ray transparency. A further feature of the new system is its high-picture quality, with a high-spatial resolution resulting from a pixel size of 0.2x0.2(mm). (author)

  6. Interferometric Laser Scanner for Direction Determination

    Directory of Open Access Journals (Sweden)

    Gennady Kaloshin

    2016-01-01

    Full Text Available In this paper, we explore the potential capabilities of new laser scanning-based method for direction determination. The method for fully coherent beams is extended to the case when interference pattern is produced in the turbulent atmosphere by two partially coherent sources. The performed theoretical analysis identified the conditions under which stable pattern may form on extended paths of 0.5–10 km in length. We describe a method for selecting laser scanner parameters, ensuring the necessary operability range in the atmosphere for any possible turbulence characteristics. The method is based on analysis of the mean intensity of interference pattern, formed by two partially coherent sources of optical radiation. Visibility of interference pattern is estimated as a function of propagation pathlength, structure parameter of atmospheric turbulence, and spacing of radiation sources, producing the interference pattern. It is shown that, when atmospheric turbulences are moderately strong, the contrast of interference pattern of laser scanner may ensure its applicability at ranges up to 10 km.

  7. Interferometric Laser Scanner for Direction Determination

    Science.gov (United States)

    Kaloshin, Gennady; Lukin, Igor

    2016-01-01

    In this paper, we explore the potential capabilities of new laser scanning-based method for direction determination. The method for fully coherent beams is extended to the case when interference pattern is produced in the turbulent atmosphere by two partially coherent sources. The performed theoretical analysis identified the conditions under which stable pattern may form on extended paths of 0.5–10 km in length. We describe a method for selecting laser scanner parameters, ensuring the necessary operability range in the atmosphere for any possible turbulence characteristics. The method is based on analysis of the mean intensity of interference pattern, formed by two partially coherent sources of optical radiation. Visibility of interference pattern is estimated as a function of propagation pathlength, structure parameter of atmospheric turbulence, and spacing of radiation sources, producing the interference pattern. It is shown that, when atmospheric turbulences are moderately strong, the contrast of interference pattern of laser scanner may ensure its applicability at ranges up to 10 km. PMID:26805841

  8. New multispectral MRI data fusion technique for white matter lesion segmentation: method and comparison with thresholding in FLAIR images

    International Nuclear Information System (INIS)

    Del C Valdes Hernandez, Maria; Ferguson, Karen J.; Chappell, Francesca M.; Wardlaw, Joanna M.

    2010-01-01

    Brain tissue segmentation by conventional threshold-based techniques may have limited accuracy and repeatability in older subjects. We present a new multispectral magnetic resonance (MR) image analysis approach for segmenting normal and abnormal brain tissue, including white matter lesions (WMLs). We modulated two 1.5T MR sequences in the red/green colour space and calculated the tissue volumes using minimum variance quantisation. We tested it on 14 subjects, mean age 73.3 ± 10 years, representing the full range of WMLs and atrophy. We compared the results of WML segmentation with those using FLAIR-derived thresholds, examined the effect of sampling location, WML amount and field inhomogeneities, and tested observer reliability and accuracy. FLAIR-derived thresholds were significantly affected by the location used to derive the threshold (P = 0.0004) and by WML volume (P = 0.0003), and had higher intra-rater variability than the multispectral technique (mean difference ± SD: 759 ± 733 versus 69 ± 326 voxels respectively). The multispectral technique misclassified 16 times fewer WMLs. Initial testing suggests that the multispectral technique is highly reproducible and accurate with the potential to be applied to routinely collected clinical MRI data. (orig.)

  9. Modeling and Calibration of a Novel One-Mirror Galvanometric Laser Scanner

    Directory of Open Access Journals (Sweden)

    Chengyi Yu

    2017-01-01

    Full Text Available A laser stripe sensor has limited application when a point cloud of geometric samples on the surface of the object needs to be collected, so a galvanometric laser scanner is designed by using a one-mirror galvanometer element as its mechanical device to drive the laser stripe to sweep along the object. A novel mathematical model is derived for the proposed galvanometer laser scanner without any position assumptions and then a model-driven calibration procedure is proposed. Compared with available model-driven approaches, the influence of machining and assembly errors is considered in the proposed model. Meanwhile, a plane-constraint-based approach is proposed to extract a large number of calibration points effectively and accurately to calibrate the galvanometric laser scanner. Repeatability and accuracy of the galvanometric laser scanner are evaluated on the automobile production line to verify the efficiency and accuracy of the proposed calibration method. Experimental results show that the proposed calibration approach yields similar measurement performance compared with a look-up table calibration method.

  10. Accuracy of four different digital intraoral scanners: effects of the presence of orthodontic brackets and wire.

    Science.gov (United States)

    Jung, Yoo-Ran; Park, Ji-Man; Chun, Youn-Sic; Lee, Kkot-Nim; Kim, Minji

    The objective of this study was to compare the accuracy of four different digital intraoral scanners and the effects of buccal brackets and orthodontic wire. For this study, three sets of models (Control model, BKT model with buccal bracket, and WBKT model with buccal bracket and orthodontic wire) were scanned using four different types of intraoral scanners: E4D dentist, iTero, Trios, and Zfx IntraScan. The mesiodistal width of the teeth, intercanine width, and intermolar width measured by four scanners were compared. Three-dimensional (3D) images of the brackets were taken using the four scanners. Data were analyzed with one-way ANOVA, independent t test, and post-hoc Tukey test at a significance level of P brackets and orthodontic wire. Comparison of 3D bracket images scanned by the four scanners showed differences in image distortion among the scanners. Bracket characteristics did not affect the 3D bracket images. The four intraoral scanners used in this study differed in accuracy. However, the results acquired by iTero and Trios were more reliable. Effects of buccal brackets and orthodontic wire on the 3D images taken by intraoral scanners were not clinically significant.

  11. The mechatronic design of a fast wire scanner in IHEP U-70 accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Baranov, V.T. [Institute for High Energy Physics in National Research Centre “Kurchatov Institute”, Protvino 142281 (Russian Federation); Makhov, S.S. [Microprivod Ltd., Moscow 111123 (Russian Federation); Savin, D.A.; Terekhov, V.I. [Institute for High Energy Physics in National Research Centre “Kurchatov Institute”, Protvino 142281 (Russian Federation)

    2016-10-11

    This paper presents the mechatronic design of a fast wire scanner based on a servomotor. The design of the wire scanner is motivated by the need to measure the transverse profile of the high power proton and carbon beams at the IHEP U-70 accelerator. This paper formulates the requirements to the fast wire scanner system for the high intensity proton beam at the U-70 accelerator. The results on the design of electro-mechanical device for the wire scanner with a wire traveling speed 10–20 m/s are presented. The solution consists in a brushless servomotor and standard motor control electronics. High radiation levels in the accelerator enclosure dictate the use of a resolver as the position feedback element.

  12. In vivo cellular imaging with microscopes enabled by MEMS scanners

    Science.gov (United States)

    Ra, Hyejun

    High-resolution optical imaging plays an important role in medical diagnosis and biomedical research. Confocal microscopy is a widely used imaging method for obtaining cellular and sub-cellular images of biological tissue in reflectance and fluorescence modes. Its characteristic optical sectioning capability also enables three-dimensional (3-D) image reconstruction. However, its use has mostly been limited to excised tissues due to the requirement of high numerical aperture (NA) lenses for cellular resolution. Microscope miniaturization can enable in vivo imaging to make possible early cancer diagnosis and biological studies in the innate environment. In this dissertation, microscope miniaturization for in vivo cellular imaging is presented. The dual-axes confocal (DAC) architecture overcomes limitations of the conventional single-axis confocal (SAC) architecture to allow for miniaturization with high resolution. A microelectromechanical systems (MEMS) scanner is the central imaging component that is key in miniaturization of the DAC architecture. The design, fabrication, and characterization of the two-dimensional (2-D) MEMS scanner are presented. The gimbaled MEMS scanner is fabricated on a double silicon-on-insulator (SOI) wafer and is actuated by self-aligned vertical electrostatic combdrives. The imaging performance of the MEMS scanner in a DAC configuration is shown in a breadboard microscope setup, where reflectance and fluorescence imaging is demonstrated. Then, the MEMS scanner is integrated into a miniature DAC microscope. The whole imaging system is integrated into a portable unit for research in small animal models of human biology and disease. In vivo 3-D imaging is demonstrated on mouse skin models showing gene transfer and siRNA silencing. The siRNA silencing process is sequentially imaged in one mouse over time.

  13. Nondestructive and intuitive determination of circadian chlorophyll rhythms in soybean leaves using multispectral imaging

    Science.gov (United States)

    Pan, Wen-Juan; Wang, Xia; Deng, Yong-Ren; Li, Jia-Hang; Chen, Wei; Chiang, John Y.; Yang, Jian-Bo; Zheng, Lei

    2015-01-01

    The circadian clock, synchronized by daily cyclic environmental cues, regulates diverse aspects of plant growth and development and increases plant fitness. Even though much is known regarding the molecular mechanism of circadian clock, it remains challenging to quantify the temporal variation of major photosynthesis products as well as their metabolic output in higher plants in a real-time, nondestructive and intuitive manner. In order to reveal the spatial-temporal scenarios of photosynthesis and yield formation regulated by circadian clock, multispectral imaging technique has been employed for nondestructive determination of circadian chlorophyll rhythms in soybean leaves. By utilizing partial least square regression analysis, the determination coefficients R2, 0.9483 for chlorophyll a and 0.8906 for chlorophyll b, were reached, respectively. The predicted chlorophyll contents extracted from multispectral data showed an approximately 24-h rhythm which could be entrained by external light conditions, consistent with the chlorophyll contents measured by chemical analyses. Visualization of chlorophyll map in each pixel offers an effective way to analyse spatial-temporal distribution of chlorophyll. Our results revealed the potentiality of multispectral imaging as a feasible nondestructive universal assay for examining clock function and robustness, as well as monitoring chlorophyll a and b and other biochemical components in plants. PMID:26059057

  14. Financing technical-medical activities. CT scanner example in France (1986)

    International Nuclear Information System (INIS)

    Meyer, C.; Lefaure, C.; Fagnani, F.

    1988-01-01

    To analyze the french methods for financing technical-medical activities as CT scanners, and to assess if they can face, or not, the management constraints of such activities a financial simulation has been executed. First, current expenditures are totalized (including depreciations and financial charges) with variations according to the numer of examinations per year. Costs are classified especially according to fixed and variable charges: the weight of fixed charges, especially equipment charges, is the most significant. It's very high in yearly expenditures. Most, that involves a very fast decreasing cost with increasing number of procedures. Second, consequences of such accounts are analyzed: - on private CT scanners, Payed with a charge per examination whatever would be the factor's cost; - on public CT scanners, payed with an annual allowance; in this case charges equal receipts whatever would be the cost for a procedure. Third, a break point is defined; either the annual activity is higher: there would be an excedent; either it is lower: there would be a deficit. Then, those results are reported to CT-scanners activity's data in France (1986). After all, financing systems themselves, are discussed and a few hypothesis to explain those desadjustments between charges and their financing way are suggested [fr

  15. Determination of astaxanthin concentration in Rainbow trout (Oncorhynchus mykiss) by multispectral image analysis

    DEFF Research Database (Denmark)

    Frosch, Stina; Dissing, Bjørn Skovlund; Ersbøll, Bjarne Kjær

    Astaxanthin is the single most expensive constituent in salmonide fish feed. Therefore control and optimization of the astaxanthin concentration from feed to fish is of paramount importance for a cost effective salmonide production. Traditionally, methods for astaxanthin determination include...... extraction of astaxanthin from the minced sample into a suitable solvent such as acetone or hexane before further analysis. The existing methods have several drawbacks including being destructive and labour consuming. Current state-of-the art vision systems for quality and process control in the fish...... to a larger degree than in a trichromatic image. In this study multispectral imaging has been evaluated for characterization of the concentration of astaxanthin in rainbow trout fillets. Rainbow trout’s (Oncorhynchus mykiss), were filleted and imaged using a rapid multispectral imaging device...

  16. Novelty Detection Classifiers in Weed Mapping: Silybum marianum Detection on UAV Multispectral Images.

    Science.gov (United States)

    Alexandridis, Thomas K; Tamouridou, Afroditi Alexandra; Pantazi, Xanthoula Eirini; Lagopodi, Anastasia L; Kashefi, Javid; Ovakoglou, Georgios; Polychronos, Vassilios; Moshou, Dimitrios

    2017-09-01

    In the present study, the detection and mapping of Silybum marianum (L.) Gaertn. weed using novelty detection classifiers is reported. A multispectral camera (green-red-NIR) on board a fixed wing unmanned aerial vehicle (UAV) was employed for obtaining high-resolution images. Four novelty detection classifiers were used to identify S. marianum between other vegetation in a field. The classifiers were One Class Support Vector Machine (OC-SVM), One Class Self-Organizing Maps (OC-SOM), Autoencoders and One Class Principal Component Analysis (OC-PCA). As input features to the novelty detection classifiers, the three spectral bands and texture were used. The S. marianum identification accuracy using OC-SVM reached an overall accuracy of 96%. The results show the feasibility of effective S. marianum mapping by means of novelty detection classifiers acting on multispectral UAV imagery.

  17. Oceanic turbidity and chlorophyll as inferred from ERTS-1 observations

    Science.gov (United States)

    Curran, R. J.

    1973-01-01

    Spectral signatures of phytoplankton and other obscuring effects are considered in order to determine how to best use satellite data. The results of this study were then used to analyze the spectral data obtained from the ERTS-1 multispectral scanner (MSS). The analyzed satellite data were finally compared with surface ship measurements of chlorophyll concentration. It was found that the effects of water turbidity on the multispectral imagery can be discriminated by rationing the two shortest wavelength channels so that the effect of phytoplankton is enhanced.

  18. Digital simulation of staining in histopathology multispectral images: enhancement and linear transformation of spectral transmittance.

    Science.gov (United States)

    Bautista, Pinky A; Yagi, Yukako

    2012-05-01

    Hematoxylin and eosin (H&E) stain is currently the most popular for routine histopathology staining. Special and/or immuno-histochemical (IHC) staining is often requested to further corroborate the initial diagnosis on H&E stained tissue sections. Digital simulation of staining (or digital staining) can be a very valuable tool to produce the desired stained images from the H&E stained tissue sections instantaneously. We present an approach to digital staining of histopathology multispectral images by combining the effects of spectral enhancement and spectral transformation. Spectral enhancement is accomplished by shifting the N-band original spectrum of the multispectral pixel with the weighted difference between the pixel's original and estimated spectrum; the spectrum is estimated using M transformed to the spectral configuration associated to its reaction to a specific stain by utilizing an N × N transformation matrix, which is derived through application of least mean squares method to the enhanced and target spectral transmittance samples of the different tissue components found in the image. Results of our experiments on the digital conversion of an H&E stained multispectral image to its Masson's trichrome stained equivalent show the viability of the method.

  19. SPECTRUM analysis of multispectral imagery in conjunction with wavelet/KLT data compression

    Energy Technology Data Exchange (ETDEWEB)

    Bradley, J.N.; Brislawn, C.M.

    1993-12-01

    The data analysis program, SPECTRUM, is used for fusion, visualization, and classification of multi-spectral imagery. The raw data used in this study is Landsat Thematic Mapper (TM) 7-channel imagery, with 8 bits of dynamic range per channel. To facilitate data transmission and storage, a compression algorithm is proposed based on spatial wavelet transform coding and KLT decomposition of interchannel spectral vectors, followed by adaptive optimal multiband scalar quantization. The performance of SPECTRUM clustering and visualization is evaluated on compressed multispectral data. 8-bit visualizations of 56-bit data show little visible distortion at 50:1 compression and graceful degradation at higher compression ratios. Two TM images were processed in this experiment: a 1024 x 1024-pixel scene of the region surrounding the Chernobyl power plant, taken a few months before the reactor malfunction, and a 2048 x 2048 image of Moscow and surrounding countryside.

  20. Self-training-based spectral image reconstruction for art paintings with multispectral imaging.

    Science.gov (United States)

    Xu, Peng; Xu, Haisong; Diao, Changyu; Ye, Zhengnan

    2017-10-20

    A self-training-based spectral reflectance recovery method was developed to accurately reconstruct the spectral images of art paintings with multispectral imaging. By partitioning the multispectral images with the k-means clustering algorithm, the training samples are directly extracted from the art painting itself to restrain the deterioration of spectral estimation caused by the material inconsistency between the training samples and the art painting. Coordinate paper is used to locate the extracted training samples. The spectral reflectances of the extracted training samples are acquired indirectly with a spectroradiometer, and the circle Hough transform is adopted to detect the circle measuring area of the spectroradiometer. Through simulation and a practical experiment, the implementation of the proposed method is explained in detail, and it is verified to have better reflectance recovery performance than that using the commercial target and is comparable to the approach using a painted color target.

  1. Design and evaluation of a low thermal electromotive force guarded scanner for resistance measurements

    Science.gov (United States)

    Jarrett, Dean G.; Marshall, James A.; Marshall, Thomas A.; Dziuba, Ronald F.

    1999-06-01

    The design and testing of a low thermal electromotive force guarded scanner, developed to provide completely guarded switching when used with actively guarded resistance bridge networks, is described. The design provides a continuous guard circuit trace on the scanner circuit boards that surrounds the relay contacts and protects the measurement circuit from leakages to ground. Modification to the circuit boards and relays of the guarded scanner are explained. Several tests were developed to evaluate the guarding effectiveness, including isolating sections of the guard circuit to create a potential drop between the main and guard circuits. Calibration of standard resistors using the guarded scanner has shown relative differences less than 1×10-6, 30×10-6, and 150×10-6 for measurements made with and without the guarded scanner at nominal resistances of 1, 10, and 100 GΩ, respectively. The substitution method was used to significantly reduce the relative differences between channels to less than 0.5×10-6, 3×10-6, and 30×10-6 for nominal resistances of 1, 10, and 100 GΩ, respectively. Applications for the guarded scanner in automated direct current measurement systems are presented.

  2. A two-dimensional micro scanner integrated with a piezoelectric actuator and piezoresistors.

    Science.gov (United States)

    Zhang, Chi; Zhang, Gaofei; You, Zheng

    2009-01-01

    A compact two-dimensional micro scanner with small volume, large deflection angles and high frequency is presented and the two-dimensional laser scanning is achieved by specular reflection. To achieve large deflection angles, the micro scanner excited by a piezoelectric actuator operates in the resonance mode. The scanning frequencies and the maximum scanning angles of the two degrees of freedom are analyzed by modeling and simulation of the structure. For the deflection angle measurement, piezoresistors are integrated in the micro scanner. The appropriate directions and crystal orientations of the piezoresistors are designed to obtain the large piezoresistive coefficients for the high sensitivities. Wheatstone bridges are used to measure the deflection angles of each direction independently and precisely. The scanner is fabricated and packaged with the piezoelectric actuator and the piezoresistors detection circuits in a size of 28 mm×20 mm×18 mm. The experiment shows that the two scanning frequencies are 216.8 Hz and 464.8 Hz, respectively. By an actuation displacement of 10 μm, the scanning range of the two-dimensional micro scanner is above 26° × 23°. The deflection angle measurement sensitivities for two directions are 59 mV/deg and 30 mV/deg, respectively.

  3. High-speed two-dimensional laser scanner based on Bragg gratings stored in photothermorefractive glass.

    Science.gov (United States)

    Yaqoob, Zahid; Arain, Muzammil A; Riza, Nabeel A

    2003-09-10

    A high-speed free-space wavelength-multiplexed optical scanner with high-speed wavelength selection coupled with narrowband volume Bragg gratings stored in photothermorefractive (PTR) glass is reported. The proposed scanner with no moving parts has a modular design with a wide angular scan range, accurate beam pointing, low scanner insertion loss, and two-dimensional beam scan capabilities. We present a complete analysis and design procedure for storing multiple tilted Bragg-grating structures in a single PTR glass volume (for normal incidence) in an optimal fashion. Because the scanner design is modular, many PTR glass volumes (each having multiple tilted Bragg-grating structures) can be stacked together, providing an efficient throughput with operations in both the visible and the infrared (IR) regions. A proof-of-concept experimental study is conducted with four Bragg gratings in independent PTR glass plates, and both visible and IR region scanner operations are demonstrated.

  4. Current segmented gamma-ray scanner technology

    International Nuclear Information System (INIS)

    Bjork, C.W.

    1987-01-01

    A new generation of segmented gamma-ray scanners has been developed at Los Alamos for scrap and waste measurements at the Savannah River Plant and the Los Alamos Plutonium Facility. The new designs are highly automated and exhibit special features such as good segmentation and thorough shielding to improve performance

  5. [A Method to Reconstruct Surface Reflectance Spectrum from Multispectral Image Based on Canopy Radiation Transfer Model].

    Science.gov (United States)

    Zhao, Yong-guang; Ma, Ling-ling; Li, Chuan-rong; Zhu, Xiao-hua; Tang, Ling-li

    2015-07-01

    Due to the lack of enough spectral bands for multi-spectral sensor, it is difficult to reconstruct surface retlectance spectrum from finite spectral information acquired by multi-spectral instrument. Here, taking into full account of the heterogeneity of pixel from remote sensing image, a method is proposed to simulate hyperspectral data from multispectral data based on canopy radiation transfer model. This method first assumes the mixed pixels contain two types of land cover, i.e., vegetation and soil. The sensitive parameters of Soil-Leaf-Canopy (SLC) model and a soil ratio factor were retrieved from multi-spectral data based on Look-Up Table (LUT) technology. Then, by combined with a soil ratio factor, all the parameters were input into the SLC model to simulate the surface reflectance spectrum from 400 to 2 400 nm. Taking Landsat Enhanced Thematic Mapper Plus (ETM+) image as reference image, the surface reflectance spectrum was simulated. The simulated reflectance spectrum revealed different feature information of different surface types. To test the performance of this method, the simulated reflectance spectrum was convolved with the Landsat ETM + spectral response curves and Moderate Resolution Imaging Spectrometer (MODIS) spectral response curves to obtain the simulated Landsat ETM+ and MODIS image. Finally, the simulated Landsat ETM+ and MODIS images were compared with the observed Landsat ETM+ and MODIS images. The results generally showed high correction coefficients (Landsat: 0.90-0.99, MODIS: 0.74-0.85) between most simulated bands and observed bands and indicated that the simulated reflectance spectrum was well simulated and reliable.

  6. Basic study of entire whole-body PET scanners based on the OpenPET geometry

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Eiji, E-mail: rush@nirs.go.j [National Institute of Radiological Sciences, 4-9-1 Inage-ku, Chiba 263-8555 (Japan); Yamaya, Taiga; Nishikido, Fumihiko; Inadama, Naoko; Murayama, Hideo [National Institute of Radiological Sciences, 4-9-1 Inage-ku, Chiba 263-8555 (Japan)

    2010-09-21

    A conventional PET scanner has a 15-25 cm axial field-of-view (FOV) and images a whole body using about six bed positions. An OpenPET geometry can extend the axial FOV with a limited number of detectors. The entire whole-body PET scanner must be able to process a large amount of data effectively. In this work, we study feasibility of the fully 3D entire whole-body PET scanner using the GATE simulation. The OpenPET has 12 block detector rings with the ring diameter of 840 mm and each block detector ring consists of 48 depth-of-interaction (DOI) detectors. The OpenPET has the axial length of 895.95 mm with five parts of 58.95 mm open gaps. The OpenPET has higher single data loss than a conventional PET scanner at grouping circuits. NECR of the OpenPET decreases by single data loss. But single data loss is mitigated by separating the axially arranged detector into two parts. Also, multiple coincidences are found to be important for the entire whole-body PET scanner. The entire whole-body PET scanner with the OpenPET geometry promises to provide a large axial FOV with the open space and to have sufficient performance values. But single data loss at the grouping circuits and multiple coincidences are limited to the peak noise equivalent count rate (NECR) for the entire whole-body PET scanner.

  7. Evaluation of scattered radiation emitted from X-ray security scanners on occupational dose to airport personnel

    International Nuclear Information System (INIS)

    Dalah, Entesar; Fakhry, Angham; Mukhtar, Asma; Al Salti, Farah; Bader, May; Khouri, Sara; Al-Zahmi, Reem

    2017-01-01

    Based on security issues and regulations airports are provided with luggage cargo scanners. These scanners utilize ionizing radiation that in principle present health risks toward humans. The study aims to investigate the amount of backscatter produced by passenger luggage and cargo toward airport personnel who are located at different distances from the scanners. To approach our investigation a Thermo Electron Radeye-G probe was used to quantify the backscattered radiation measured in terms of dose-rate emitted from airport scanners, Measurements were taken at the entrance and exit positions of the X-ray tunnel at three different distances (0, 50, and 100 cm) for two different scanners; both scanners include shielding curtains that reduce scattered radiation. Correlation was demonstrated using the Pearson coefficient test. Measurements confirmed an inverse relationship between dose rate and distance. An estimated occupational accumulative dose of 0.88 mSv/y, and 2.04 mSv/y were obtained for personnel working in inspection of carry-on, and cargo, respectively. Findings confirm that the projected dose of security and engineering staff are being well within dose limits. - Highlights: • Backscattered radiation emitted from the airport security scanners is estimated. • Inverse relation observed between backscattered radiation and scanners distance. • Occupational dose for personnel inspecting the scanners were up to 2.04 mSv/y. • The projected dose of security and engineering staff are well within dose limits.

  8. Determining the surface roughness coefficient by 3D Scanner

    Directory of Open Access Journals (Sweden)

    Karmen Fifer Bizjak

    2010-12-01

    Full Text Available Currently, several test methods can be used in the laboratory to determine the roughness of rock joint surfaces.However, true roughness can be distorted and underestimated by the differences in the sampling interval of themeasurement methods. Thus, these measurement methods produce a dead zone and distorted roughness profiles.In this paper a new rock joint surface roughness measurement method is presented, with the use of a camera-typethree-dimensional (3D scanner as an alternative to current methods. For this study, the surfaces of ten samples oftuff were digitized by means of a 3D scanner, and the results were compared with the corresponding Rock JointCoefficient (JRC values. Up until now such 3D scanner have been mostly used in the automotive industry, whereastheir use for comparison with obtained JRC coefficient values in rock mechanics is presented here for the first time.The proposed new method is a faster, more precise and more accurate than other existing test methods, and is apromising technique for use in this area of study in the future.

  9. Precision of dosimetry-related measurements obtained on current multidetector computed tomography scanners

    International Nuclear Information System (INIS)

    Mathieu, Kelsey B.; McNitt-Gray, Michael F.; Zhang, Di; Kim, Hyun J.; Cody, Dianna D.

    2010-01-01

    Purpose: Computed tomography (CT) intrascanner and interscanner variability has not been well characterized. Thus, the purpose of this study was to examine the within-run, between-run, and between-scanner precision of physical dosimetry-related measurements collected over the course of 1 yr on three different makes and models of multidetector row CT (MDCT) scanners. Methods: Physical measurements were collected using nine CT scanners (three scanners each of GE VCT, GE LightSpeed 16, and Siemens Sensation 64 CT). Measurements were made using various combinations of technical factors, including kVp, type of bowtie filter, and x-ray beam collimation, for several dosimetry-related quantities, including (a) free-in-air CT dose index (CTDI 100,air ); (b) calculated half-value layers and quarter-value layers; and (c) weighted CT dose index (CTDI w ) calculated from exposure measurements collected in both a 16 and 32 cm diameter CTDI phantom. Data collection was repeated at several different time intervals, ranging from seconds (for CTDI 100,air values) to weekly for 3 weeks and then quarterly or triannually for 1 yr. Precision of the data was quantified by the percent coefficient of variation (%CV). Results: The maximum relative precision error (maximum %CV value) across all dosimetry metrics, time periods, and scanners included in this study was 4.33%. The median observed %CV values for CTDI 100,air ranged from 0.05% to 0.19% over several seconds, 0.12%-0.52% over 1 week, and 0.58%-2.31% over 3-4 months. For CTDI w for a 16 and 32 cm CTDI phantom, respectively, the range of median %CVs was 0.38%-1.14% and 0.62%-1.23% in data gathered weekly for 3 weeks and 1.32%-2.79% and 0.84%-2.47% in data gathered quarterly or triannually for 1 yr. Conclusions: From a dosimetry perspective, the MDCT scanners tested in this study demonstrated a high degree of within-run, between-run, and between-scanner precision (with relative precision errors typically well under 5%).

  10. Evaluation of radiation leakage of the scanner HCV-mobile of the port of Toamasina and the scanner THSCAN of the station of Soarano Antananarivo

    International Nuclear Information System (INIS)

    RAZAKARIMANANA, T.

    2011-01-01

    This work was performed at Madagascar-INSTN in collaboration with the GasyNet Company.In order to improve the use of X-rays scanners for control of containers at the SPAT Toamasina and the Soarano Antananarivo's station, the protection of workers and the public against the harmful effects of the ionizing radiation should be strengthen. According to the results obtained in two scanners (HCV-Mobile and THSCAN), the company GasyNet has a system of radiation protection appropriate, dose rates measured do not exceed the regulation standards.The use of devices for checking a leak radiations and the respect of three means of protection (time, distance, and screen) are the most effective means to protect the workers and public against the harmful effects of ionizing radiation emitted by scanners of x-ray. However, to avoid the incidents and accidents, it is necessary to respect and to apply the standards and the national regulations in force. [fr

  11. Predicting visibility of aircraft.

    Directory of Open Access Journals (Sweden)

    Andrew Watson

    Full Text Available Visual detection of aircraft by human observers is an important element of aviation safety. To assess and ensure safety, it would be useful to be able to be able to predict the visibility, to a human observer, of an aircraft of specified size, shape, distance, and coloration. Examples include assuring safe separation among aircraft and between aircraft and unmanned vehicles, design of airport control towers, and efforts to enhance or suppress the visibility of military and rescue vehicles. We have recently developed a simple metric of pattern visibility, the Spatial Standard Observer (SSO. In this report we examine whether the SSO can predict visibility of simulated aircraft images. We constructed a set of aircraft images from three-dimensional computer graphic models, and measured the luminance contrast threshold for each image from three human observers. The data were well predicted by the SSO. Finally, we show how to use the SSO to predict visibility range for aircraft of arbitrary size, shape, distance, and coloration.

  12. Application of intra-oral dental scanners in the digital workflow of implantology

    NARCIS (Netherlands)

    van der Meer, Wicher J; Andriessen, Frank S; Wismeijer, Daniel; Ren, Yijin

    2012-01-01

    UNLABELLED: Intra-oral scanners will play a central role in digital dentistry in the near future. In this study the accuracy of three intra-oral scanners was compared. MATERIALS AND METHODS: A master model made of stone was fitted with three high precision manufactured PEEK cylinders and scanned

  13. Application of intra-oral dental scanners in the digital workflow of implantology

    NARCIS (Netherlands)

    van der Meer, W.J.; Andriessen, F.S.; Wismeijer, D.; Ren, Y.

    2012-01-01

    Intra-oral scanners will play a central role in digital dentistry in the near future. In this study the accuracy of three intra-oral scanners was compared. Materials and methods: A master model made of stone was fitted with three high precision manufactured PEEK cylinders and scanned with three

  14. The development of a mobile CT-scanner gantry for use in the operating room

    International Nuclear Information System (INIS)

    Okudera, Hiroshi; Kobayashi, Shigeaki; Koike, Jouji; Harada, Takanobu; Kanemaru, Kei

    1989-01-01

    We report the development of a mobile CT-scanner gantry which uses a gantry platter. This system has been developed for use in the operating room. We designed a small lift to move the gantry unit of the scanner: the gantry carrier. The scanner gantry is fixed to the gantry carrier. A phantom test with a digitalized operating table worked well in the laboratory, and operating-room use showed that there was no deterioration in image quality. The mobile gantry system has been developed to increase the efficiency of the operating CT-scanner system. This system enables us to obtain CT images during surgery of immediately after surgery in the operating room, i.e., in cases that are not transferable to the radiological department. The operability is basically the same as that of a conventional mobile X-ray unit. Theoretically, this unit could be used with any CT scanner and in any operating room. (author)

  15. LANSCE-R WIRE-SCANNER ANALOG FRONT-END ELECTRONICS

    International Nuclear Information System (INIS)

    Gruchalla, Michael E.

    2011-01-01

    A new AFE is being developed for the new LANSCE-R wire-scanner systems. The new AFE is implemented in a National Instruments Compact RIO (cRIO) module installed a BiRa 4U BiRIO cRIO chassis specifically designed to accommodate the cRIO crate and all the wire-scanner interface, control and motor-drive electronics. A single AFE module provides interface to both X and Y wire sensors using true DC coupled transimpedance amplifiers providing collection of the wire charge signals, real-time wire integrity verification using the normal dataacquisition system, and wire bias of 0V to +/-50V. The AFE system is designed to accommodate comparatively long macropulses (>1ms) with high PRF (>120Hz) without the need to provide timing signals. The basic AFE bandwidth is flat from true DC to 50kHz with a true first-order pole at 50kHz. Numeric integration in the cRIO FPGA provides real-time pulse-to-pulse numeric integration of the AFE signal to compute the total charge collected in each macropulse. This method of charge collection eliminates the need to provide synchronization signals to the wire-scanner AFE while providing the capability to accurately record the charge from long macropulses at high PRF.

  16. Impact of aircraft systems within aircraft operation: A MEA trajectory optimisation study

    OpenAIRE

    Seresinhe, R.

    2014-01-01

    Air transport has been a key component of the socio-economic globalisation. The ever increasing demand for air travel and air transport is a testament to the success of the aircraft. But this growing demand presents many challenges. One of which is the environmental impact due to aviation. The scope of the environmental impact of aircraft can be discussed from many viewpoints. This research focuses on the environmental impact due to aircraft operation. Aircraft operation causes...

  17. Accuracy of five intraoral scanners compared to indirect digitalization.

    Science.gov (United States)

    Güth, Jan-Frederik; Runkel, Cornelius; Beuer, Florian; Stimmelmayr, Michael; Edelhoff, Daniel; Keul, Christine

    2017-06-01

    Direct and indirect digitalization offer two options for computer-aided design (CAD)/ computer-aided manufacturing (CAM)-generated restorations. The aim of this study was to evaluate the accuracy of different intraoral scanners and compare them to the process of indirect digitalization. A titanium testing model was directly digitized 12 times with each intraoral scanner: (1) CS 3500 (CS), (2) Zfx Intrascan (ZFX), (3) CEREC AC Bluecam (BLU), (4) CEREC AC Omnicam (OC) and (5) True Definition (TD). As control, 12 polyether impressions were taken and the referring plaster casts were digitized indirectly with the D-810 laboratory scanner (CON). The accuracy (trueness/precision) of the datasets was evaluated by an analysing software (Geomagic Qualify 12.1) using a "best fit alignment" of the datasets with a highly accurate reference dataset of the testing model, received from industrial computed tomography. Direct digitalization using the TD showed the significant highest overall "trueness", followed by CS. Both performed better than CON. BLU, ZFX and OC showed higher differences from the reference dataset than CON. Regarding the overall "precision", the CS 3500 intraoral scanner and the True Definition showed the best performance. CON, BLU and OC resulted in significantly higher precision than ZFX did. Within the limitations of this in vitro study, the accuracy of the ascertained datasets was dependent on the scanning system. The direct digitalization was not superior to indirect digitalization for all tested systems. Regarding the accuracy, all tested intraoral scanning technologies seem to be able to reproduce a single quadrant within clinical acceptable accuracy. However, differences were detected between the tested systems.

  18. METHOD OF RADIOMETRIC DISTORTION CORRECTION OF MULTISPECTRAL DATA FOR THE EARTH REMOTE SENSING

    Directory of Open Access Journals (Sweden)

    A. N. Grigoriev

    2015-07-01

    Full Text Available The paper deals with technologies of ground secondary processing of heterogeneous multispectral data. The factors of heterogeneous data include uneven illumination of objects on the Earth surface caused by different properties of the relief. A procedure for the image restoration of spectral channels by means of terrain distortion compensation is developed. The object matter of this paper is to improve the quality of the results during image restoration of areas with large and medium landforms. Methods. Researches are based on the elements of the digital image processing theory, statistical processing of the observation results and the theory of multi-dimensional arrays. Main Results. The author has introduced operations on multidimensional arrays: concatenation and elementwise division. Extended model description for input data about the area is given. The model contains all necessary data for image restoration. Correction method for multispectral data radiometric distortions of the Earth remote sensing has been developed. The method consists of two phases: construction of empirical dependences for spectral reflectance on the relief properties and restoration of spectral images according to semiempirical data. Practical Relevance. Research novelty lies in developme nt of the application theory of multidimensional arrays with respect to the processing of multispectral data, together with data on the topography and terrain objects. The results are usable for development of radiometric data correction tools. Processing is performed on the basis of a digital terrain model without carrying out ground works connected with research of the objects reflective properties.

  19. Aircraft to aircraft intercomparison during SEMAPHORE

    Science.gov (United States)

    Lambert, Dominique; Durand, Pierre

    1998-10-01

    During the Structure des Echanges Mer-Atmosphère, Propriétés des Hétérogénéités Océaniques: Recherche Expérimentale (SEMAPHORE) experiment, performed in the Azores region in 1993, two French research aircraft were simultaneously used for in situ measurements in the atmospheric boundary layer. We present the results obtained from one intercomparison flight between the two aircraft. The mean parameters generally agree well, although the temperature has to be slightly shifted in order to be in agreement for the two aircraft. A detailed comparison of the turbulence parameters revealed no bias. The agreement is good for variances and is satisfactory for fluxes and skewness. A thorough study of the errors involved in flux computation revealed that the greatest accuracy is obtained for latent heat flux. Errors in sensible heat flux are considerably greater, and the worst results are obtained for momentum flux. The latter parameter, however, is more accurate than expected from previous parameterizations.

  20. SU-E-P-11: Comparison of Image Quality and Radiation Dose Between Different Scanner System in Routine Abdomen CT

    Energy Technology Data Exchange (ETDEWEB)

    Liao, S; Wang, Y; Weng, H [Chiayi Chang Gung Memorial Hospital of The C.G.M.F, Puzi City, Chiayi County, Taiwan (China)

    2015-06-15

    Purpose To evaluate image quality and radiation dose of routine abdomen computed tomography exam with the automatic current modulation technique (ATCM) performed in two different brand 64-slice CT scanners in our site. Materials and Methods A retrospective review of routine abdomen CT exam performed with two scanners; scanner A and scanner B in our site. To calculate standard deviation of the portal hepatic level with a region of interest of 12.5 mm x 12.5mm represented to the image noise. The radiation dose was obtained from CT DICOM image information. Using Computed tomography dose index volume (CTDIv) to represented CT radiation dose. The patient data in this study were with normal weight (about 65–75 Kg). Results The standard deviation of Scanner A was smaller than scanner B, the scanner A might with better image quality than scanner B. On the other hand, the radiation dose of scanner A was higher than scanner B(about higher 50–60%) with ATCM. Both of them, the radiation dose was under diagnostic reference level. Conclusion The ATCM systems in modern CT scanners can contribute a significant reduction in radiation dose to the patient. But the reduction by ATCM systems from different CT scanner manufacturers has slightly variation. Whatever CT scanner we use, it is necessary to find the acceptable threshold of image quality with the minimum possible radiation exposure to the patient in agreement with the ALARA principle.

  1. SU-E-P-11: Comparison of Image Quality and Radiation Dose Between Different Scanner System in Routine Abdomen CT

    International Nuclear Information System (INIS)

    Liao, S; Wang, Y; Weng, H

    2015-01-01

    Purpose To evaluate image quality and radiation dose of routine abdomen computed tomography exam with the automatic current modulation technique (ATCM) performed in two different brand 64-slice CT scanners in our site. Materials and Methods A retrospective review of routine abdomen CT exam performed with two scanners; scanner A and scanner B in our site. To calculate standard deviation of the portal hepatic level with a region of interest of 12.5 mm x 12.5mm represented to the image noise. The radiation dose was obtained from CT DICOM image information. Using Computed tomography dose index volume (CTDIv) to represented CT radiation dose. The patient data in this study were with normal weight (about 65–75 Kg). Results The standard deviation of Scanner A was smaller than scanner B, the scanner A might with better image quality than scanner B. On the other hand, the radiation dose of scanner A was higher than scanner B(about higher 50–60%) with ATCM. Both of them, the radiation dose was under diagnostic reference level. Conclusion The ATCM systems in modern CT scanners can contribute a significant reduction in radiation dose to the patient. But the reduction by ATCM systems from different CT scanner manufacturers has slightly variation. Whatever CT scanner we use, it is necessary to find the acceptable threshold of image quality with the minimum possible radiation exposure to the patient in agreement with the ALARA principle

  2. Survey of damage to 602 MR scanners after the Great East Japan Earthquake

    International Nuclear Information System (INIS)

    Nakai, Toshiharu; Yamaguchi-Sekino, Sachiko; Tsuchihashi, Toshio

    2013-01-01

    An earthquake of 9.0 magnitude, the largest in modern Japanese history, struck east Japan on March 11, 2011. We investigated hazards and observations related to magnetic resonance (MR) scanners in this earthquake to evaluate potential risks and consider further prevention or minimization of damage from and injury of patients in such large earthquakes. The investigation team funded by MHLW sent questionnaires to the 984 facilities with installed MR scanners in the 7 prefectures of east Japan (Iwate, Miyagi, Fukushima, Ibaraki, Chiba, Tokyo, Saitama) and collected 458 responses (46.6%) with information on 602 MR scanners (144 units≤0.5 tesla; 31 one-T units; 371 1.5-T units; and 56 units≥3 T). Significant differences in damage were observed between seismic scale 5 and 6 (χ 2 test, P<0.001 for all items of damage checked). The frequencies of typical damage were displacement of magnets (12.4%), failure of the chiller or air conditioning (9.6%), rapid decrease in liquid helium (8.4%), damage to magnet enclosure and its equipment (7.6%), damage to shielding of the MR scanner room (6.1%), damage to the quench duct (4.5%), breakage of devices anchoring system cabinets (4.4%), damage to the magnet base (3.9%), and flying of metal components (1.5%). Twelve facilities reported flooding by the subsequent tsunami, and quench was confirmed in 19 facilities. No fire damage was reported. It was confirmed that no one was severely injured in MR scanners, and base isolation of the building was very useful in completely preventing damage even at seismic scale 7. In the future, training for evacuation and establishment of a standard protocol for emergency shutdown of MR scanners, onsite checking by MR operators, and emergency power plant equipment to maintain chiller for MR scanners will further ensure MR safety in an earthquake. (author)

  3. Scanner baseliner monitoring and control in high volume manufacturing

    Science.gov (United States)

    Samudrala, Pavan; Chung, Woong Jae; Aung, Nyan; Subramany, Lokesh; Gao, Haiyong; Gomez, Juan-Manuel

    2016-03-01

    We analyze performance of different customized models on baseliner overlay data and demonstrate the reduction in overlay residuals by ~10%. Smart Sampling sets were assessed and compared with the full wafer measurements. We found that performance of the grid can still be maintained by going to one-third of total sampling points, while reducing metrology time by 60%. We also demonstrate the feasibility of achieving time to time matching using scanner fleet manager and thus identify the tool drifts even when the tool monitoring controls are within spec limits. We also explore the scanner feedback constant variation with illumination sources.

  4. Modelling the Siemens SOMATOM Sensation 64 Multi-Slice CT (MSCT) Scanner

    International Nuclear Information System (INIS)

    Amin, A T Mohd; Rahni, A A Abd

    2017-01-01

    Reconstructing large volumetric 3D images with minimal radiation dosage exposure with reduced scanning time has been one of the main objectives in the advancement of CT development. One of its advancement is the introduction of multi-slice arc detector geometry from a cone-beam source in third generation scanners. In solving this complex geometry, apart from the known vast computations in CT image reconstruction due to large CT images, iterative reconstruction methods are preferred compared to analytic methods due to its flexibility in image reconstruction. A scanner of interest that has this type of geometry is the Siemens SOMATOM Sensation 64 Multi-Slice CT (MSCT) Scanner , which has a total of 32 slices with 672 detector elements on each slice. In this paper, the scanner projection is modelled via the intersecting lengths between each ray (exhibited from the source to the detector elements) with the scanned image voxels, which are evaluated using the classical Siddon’s algorithm to generate the system matrix, H . This is a prerequisite to perform various iterative reconstruction methods, which involves solving the inverse problem arising from the linear equation: S = H· I; where S is the projections produced from the image, I. Due to the ‘cone-beam geometry’ along the z -axis, the effective field-of-view (FOV) with voxel dimensions (0.4×0.4×0.4) mm 3 is 512×512×32 voxels. The scanner model is demonstrated by reconstructing an image from simulated projections using the analytic Feldkamp-Davis-Kress (FDK) method against basic iterative image reconstruction methods. (paper)

  5. Temperature dependence of APD-based PET scanners

    International Nuclear Information System (INIS)

    Keereman, Vincent; Van Holen, Roel; Vandenberghe, Stefaan; Vanhove, Christian

    2013-01-01

    Purpose: Solid state detectors such as avalanche photodiodes (APDs) are increasingly being used in PET detectors. One of the disadvantages of APDs is the strong decrease of their gain factor with increasing ambient temperature. The light yield of most scintillation crystals also decreases when ambient temperature is increased. Both effects lead to considerable temperature dependence of the performance of APD-based PET scanners. In this paper, the authors propose a model for this dependence and the performance of the LabPET8 APD-based small animal PET scanner is evaluated at different temperatures.Methods: The model proposes that the effect of increasing temperature on the energy histogram of an APD-based PET scanner is a compression of the histogram along the energy axis. The energy histogram of the LabPET system was acquired at 21 °C and 25 °C to verify the validity of this model. Using the proposed model, the effect of temperature on system sensitivity was simulated for different detector temperature coefficients and temperatures. Subsequently, the effect of short term and long term temperature changes on the peak sensitivity of the LabPET system was measured. The axial sensitivity profile was measured at 21 °C and 24 °C following the NEMA NU 4-2008 standard. System spatial resolution was also evaluated. Furthermore, scatter fraction, count losses and random coincidences were evaluated at different temperatures. Image quality was also investigated.Results: As predicted by the model, the photopeak energy at 25 °C is lower than at 21 °C with a shift of approximately 6% per °C. Simulations showed that this results in an approximately linear decrease of sensitivity when temperature is increased from 21 °C to 24 °C and energy thresholds are constant. Experimental evaluation of the peak sensitivity at different temperatures showed a strong linear correlation for short term (2.32 kcps/MBq/°C = 12%/°C, R = −0.95) and long term (1.92 kcps/MBq/°C = 10%/

  6. Optical detection of Prorocentrum donghaiense blooms based on multispectral reflectance

    Institute of Scientific and Technical Information of China (English)

    TAO Bangyi; PAN Delu; MAO Zhihua; SHEN Yuzhang; ZHU Qiankun; CHEN Jianyu

    2013-01-01

    Prorocentrum donghaiense is one of the most common red tide causative dinoflagellates in the Changjiang (Yangtze) River Estuary and the adjacent area of the East China Sea. It causes large-scale blooms in late spring and early summer that lead to widespread ecologic and economic damage. A means for distinguish-ing dinoflagellate blooms from diatom (Skeletonema costatum) blooms is desired. On the basis of measure-ments of remote sensing reflectance [Rrs(λ)] and inherent optical parameters, the potential of using a mul-tispectral approach is assessed for discriminating the algal blooms due to P. donghaiense from those due to S. costatum. The behavior of two reflectance ratios [R1 =Rrs(560)/Rrs(532) and R2 =Rrs(708)/Rrs(665)], suggests that differentiation of P. donghaiense blooms from diatom bloom types is possible from the current band setup of ocean color sensors. It is found that there are two reflectance ratio regimes that indicate a bloom is dominated by P. donghaiense: (1) R1 >1.55 and R2 1.75 and R2 ?1.0. Various sensitivity analyses are conducted to investigate the effects of the variation in varying levels of chlorophyll concentration and colored dissolved organic matter (CDOM) as well as changes in the backscattering ratio (bbp/bp) on the efficacy of this multispectral approach. Results indicate that the intensity and inherent op-tical properties of the algal species explain much of the behavior of the two ratios. Although backscattering influences the amplitude of Rrs(λ), especially in the 530 and 560 nm bands, the discrimination between P. donghaiense and diatoms is not significantly affected by the variation of bbp/bp. Since a CDOM(440) in coastal areas of the ECS is typically lower than 1.0 m−1 in most situations, the presence of CDOM does not interfere with this discrimination, even as SCDOM varies from 0.01 to 0.026 nm−1. Despite all of these effects, the dis-crimination of P. donghaiense blooms from diatom blooms based on multispectral

  7. Automatic Tree Data Removal Method for Topography Measurement Result Using Terrestrial Laser Scanner

    Science.gov (United States)

    Yokoyama, H.; Chikatsu, H.

    2017-02-01

    Recently, laser scanning has been receiving greater attention as a useful tool for real-time 3D data acquisition, and various applications such as city modelling, DTM generation and 3D modelling of cultural heritage sites have been proposed. And, former digital data processing were demanded in the past digital archive techniques for cultural heritage sites. However, robust filtering method for distinguishing on- and off-terrain points by terrestrial laser scanner still have many issues. In the past investigation, former digital data processing using air-bone laser scanner were reported. Though, efficient tree removal methods from terrain points for the cultural heritage are not considered. In this paper, authors describe a new robust filtering method for cultural heritage using terrestrial laser scanner with "the echo digital processing technology" as latest data processing techniques of terrestrial laser scanner.

  8. A Two-Dimensional Micro Scanner Integrated with a Piezoelectric Actuator and Piezoresistors

    Directory of Open Access Journals (Sweden)

    Zheng You

    2009-01-01

    Full Text Available A compact two-dimensional micro scanner with small volume, large deflection angles and high frequency is presented and the two-dimensional laser scanning is achieved by specular reflection. To achieve large deflection angles, the micro scanner excited by a piezoelectric actuator operates in the resonance mode. The scanning frequencies and the maximum scanning angles of the two degrees of freedom are analyzed by modeling and simulation of the structure. For the deflection angle measurement, piezoresistors are integrated in the micro scanner. The appropriate directions and crystal orientations of the piezoresistors are designed to obtain the large piezoresistive coefficients for the high sensitivities. Wheatstone bridges are used to measure the deflection angles of each direction independently and precisely. The scanner is fabricated and packaged with the piezoelectric actuator and the piezoresistors detection circuits in a size of 28 mm×20 mm×18 mm. The experiment shows that the two scanning frequencies are 216.8 Hz and 464.8 Hz, respectively. By an actuation displacement of 10 μm, the scanning range of the two-dimensional micro scanner is above 26º × 23º. The deflection angle measurement sensitivities for two directions are 59 mV/deg and 30 mV/deg, respectively.

  9. Landscape functioning assessment using Landsat multispectral remote sensing data

    OpenAIRE

    Hesslerová, Petra

    2009-01-01

    The main aim of the dissertation thesis was to develop method, based on the use of multispectral satellite data and the theory of dissipation, allowing the analysis of landscape functioning. The theoretical basis is Prigogine's theory of dissipation and self-organization of structures in which energy dissipation is seen as the transformation of solar energy to other forms of energy. In this process the essential role play water availability and vegetation, which is able to bind solar radiatio...

  10. Comparison of coronary artery calcium screening image quality between C-150 and e-Speed electron beam scanners.

    Science.gov (United States)

    Budoff, Matthew J; Shinbane, Jerold S; Oudiz, Ronald J; Child, Janis; Carson, Sivi; Chau, Alex; Tseng, Philip; Gao, Yanlin; Mao, Songshou

    2005-03-01

    The newest generation of electron beam tomographic scanner (e-Speed) has increased spatial and temporal resolution compared with the C-150 XP scanner. The aim of this study was to evaluate coronary artery calcium screening image quality between the e-Speed and C-150 scanners (GE Imatron, San Francisco, CA). Studies from 41 patients (14 women and 27 men) who underwent serial coronary artery calcium screening with the C-150 (first study) and the e-Speed (second study) were analyzed. Individual computed tomography (CT) slices were assessed for coronary artery motion artifacts, and CT Hounsfield units (HU) and noise values (CT HU standard deviation) at 16 discrete cardiac sites were measured and averaged. With the e-Speed scanner, there were significant decreases in right coronary artery motion artifacts compared with the C-150 scanner (0.3% versus 1.8%, P Image quality is significantly improved with use of the e-Speed scanner, due to its improved temporal and spatial resolution, compared with the C-150 scanner.

  11. An Enhanced Rule-Based Web Scanner Based on Similarity Score

    Directory of Open Access Journals (Sweden)

    LEE, M.

    2016-08-01

    Full Text Available This paper proposes an enhanced rule-based web scanner in order to get better accuracy in detecting web vulnerabilities than the existing tools, which have relatively high false alarm rate when the web pages are installed in unconventional directory paths. Using the proposed matching method based on similarity score, the proposed scheme can determine whether two pages have the same vulnerabilities or not. With this method, the proposed scheme is able to figure out the target web pages are vulnerable by comparing them to the web pages that are known to have vulnerabilities. We show the proposed scanner reduces 12% false alarm rate compared to the existing well-known scanner through the performance evaluation via various experiments. The proposed scheme is especially helpful in detecting vulnerabilities of the web applications which come from well-known open-source web applications after small customization, which happens frequently in many small-sized companies.

  12. Dental impressions using 3D digital scanners: virtual becomes reality.

    Science.gov (United States)

    Birnbaum, Nathan S; Aaronson, Heidi B

    2008-10-01

    The technologies that have made the use of three-dimensional (3D) digital scanners an integral part of many industries for decades have been improved and refined for application to dentistry. Since the introduction of the first dental impressioning digital scanner in the 1980s, development engineers at a number of companies have enhanced the technologies and created in-office scanners that are increasingly user-friendly and able to produce precisely fitting dental restorations. These systems are capable of capturing 3D virtual images of tooth preparations, from which restorations may be fabricated directly (ie, CAD/CAM systems) or fabricated indirectly (ie, dedicated impression scanning systems for the creation of accurate master models). The use of these products is increasing rapidly around the world and presents a paradigm shift in the way in which dental impressions are made. Several of the leading 3D dental digital scanning systems are presented and discussed in this article.

  13. A workflow for extracting plot-level biophysical indicators from aerially acquired multispectral imagery

    Science.gov (United States)

    Advances in technologies associated with unmanned aerial vehicles (UAVs) has allowed for researchers, farmers and agribusinesses to incorporate UAVs coupled with various imaging systems into data collection activities and aid expert systems for making decisions. Multispectral imageries allow for a q...

  14. Deepwater Horizon - Estimating surface oil volume distribution in real time

    Science.gov (United States)

    Lehr, B.; Simecek-Beatty, D.; Leifer, I.

    2011-12-01

    Spill responders to the Deepwater Horizon (DWH) oil spill required both the relative spatial distribution and total oil volume of the surface oil. The former was needed on a daily basis to plan and direct local surface recovery and treatment operations. The latter was needed less frequently to provide information for strategic response planning. Unfortunately, the standard spill observation methods were inadequate for an oil spill this size, and new, experimental, methods, were not ready to meet the operational demands of near real-time results. Traditional surface oil estimation tools for large spills include satellite-based sensors to define the spatial extent (but not thickness) of the oil, complemented with trained observers in small aircraft, sometimes supplemented by active or passive remote sensing equipment, to determine surface percent coverage of the 'thick' part of the slick, where the vast majority of the surface oil exists. These tools were also applied to DWH in the early days of the spill but the shear size of the spill prevented synoptic information of the surface slick through the use small aircraft. Also, satellite images of the spill, while large in number, varied considerably in image quality, requiring skilled interpretation of them to identify oil and eliminate false positives. Qualified staff to perform this task were soon in short supply. However, large spills are often events that overcome organizational inertia to the use of new technology. Two prime examples in DWH were the application of hyper-spectral scans from a high-altitude aircraft and more traditional fixed-wing aircraft using multi-spectral scans processed by use of a neural network to determine, respectively, absolute or relative oil thickness. But, with new technology, come new challenges. The hyper-spectral instrument required special viewing conditions that were not present on a daily basis and analysis infrastructure to process the data that was not available at the command

  15. Algorithms for Coastal-Zone Color-Scanner Data

    Science.gov (United States)

    1986-01-01

    Software for Nimbus-7 Coastal-Zone Color-Scanner (CZCS) derived products consists of set of scientific algorithms for extracting information from CZCS-gathered data. Software uses CZCS-generated Calibrated RadianceTemperature (CRT) tape as input and outputs computer-compatible tape and film product.

  16. REMOTELY SENSEDC IMAGE COMPRESSION BASED ON WAVELET TRANSFORM

    Directory of Open Access Journals (Sweden)

    Heung K. Lee

    1996-06-01

    Full Text Available In this paper, we present an image compression algorithm that is capable of significantly reducing the vast mount of information contained in multispectral images. The developed algorithm exploits the spectral and spatial correlations found in multispectral images. The scheme encodes the difference between images after contrast/brightness equalization to remove the spectral redundancy, and utilizes a two-dimensional wavelet trans-form to remove the spatial redundancy. The transformed images are than encoded by hilbert-curve scanning and run-length-encoding, followed by huffman coding. We also present the performance of the proposed algorithm with KITSAT-1 image as well as the LANDSAT MultiSpectral Scanner data. The loss of information is evaluated by peak signal to noise ratio (PSNR and classification capability.

  17. An Approach for Unsupervised Change Detection in Multitemporal VHR Images Acquired by Different Multispectral Sensors

    Directory of Open Access Journals (Sweden)

    Yady Tatiana Solano-Correa

    2018-03-01

    Full Text Available This paper proposes an approach for the detection of changes in multitemporal Very High Resolution (VHR optical images acquired by different multispectral sensors. The proposed approach, which is inspired by a recent framework developed to support the design of change-detection systems for single-sensor VHR remote sensing images, addresses and integrates in the general approach a strategy to effectively deal with multisensor information, i.e., to perform change detection between VHR images acquired by different multispectral sensors on two dates. This is achieved by the definition of procedures for the homogenization of radiometric, spectral and geometric image properties. These procedures map images into a common feature space where the information acquired by different multispectral sensors becomes comparable across time. Although the approach is general, here we optimize it for the detection of changes in vegetation and urban areas by employing features based on linear transformations (Tasseled Caps and Orthogonal Equations, which are shown to be effective for representing the multisensor information in a homogeneous physical way irrespectively of the considered sensor. Experiments on multitemporal images acquired by different VHR satellite systems (i.e., QuickBird, WorldView-2 and GeoEye-1 confirm the effectiveness of the proposed approach.

  18. Removal of Optically Thick Clouds from Multi-Spectral Satellite Images Using Multi-Frequency SAR Data

    Directory of Open Access Journals (Sweden)

    Robert Eckardt

    2013-06-01

    Full Text Available This study presents a method for the reconstruction of pixels contaminated by optical thick clouds in multi-spectral Landsat images using multi-frequency SAR data. A number of reconstruction techniques have already been proposed in the scientific literature. However, all of the existing techniques have certain limitations. In order to overcome these limitations, we expose the Closest Spectral Fit (CSF method proposed by Meng et al. to a new, synergistic approach using optical and SAR data. Therefore, the term Closest Feature Vector (CFV is introduced. The technique facilitates an elegant way to avoid radiometric distortions in the course of image reconstruction. Furthermore the cloud cover removal is independent from underlying land cover types and assumptions on seasonality, etc. The methodology is applied to mono-temporal, multi-frequency SAR data from TerraSAR-X (X-Band, ERS (C-Band and ALOS Palsar (L-Band. This represents a way of thinking about Radar data not as foreign, but as additional data source in multi-spectral remote sensing. For the assessment of the image restoration performance, an experimental framework is established and a statistical evaluation protocol is designed. The results show the potential of a synergistic usage of multi-spectral and SAR data to overcome the loss of data due to cloud cover.

  19. Laser scanner 3D terrestri e mobile

    Directory of Open Access Journals (Sweden)

    Mario Ciamba

    2013-08-01

    Full Text Available Recentemente si è svolto a Roma un evento dimostrativo per informare, professionisti e ricercatori del settore inerente il rilievo strumentale, sulle recenti innovazioni che riguardano i laser scanner 3d. Il mercato della strumentazione dedicata al rilevamento architettonico e dell'ambiente, offre molte possibilità di scelta. Oggi i principali marchi producono strumenti sempre più efficienti ed ideati per ambiti di applicazione specifici, permettendo ai professionisti, la giusta scelta in termini di prestazioni ed economia. A demonstration event was recently held in Rome with the aim to inform professionals and researchers on recent innovations on instrumental survey related to the 3d laser scanner. The market of instrumentation for architectural survey offers many possibilitiesof choice. Today the major brands produce instruments that are more efficient and designed for specific areas of application, allowing the right choice in terms of performance and economy.

  20. Laser scanner 3D terrestri e mobile

    Directory of Open Access Journals (Sweden)

    Mario Ciamba

    2013-08-01

    Full Text Available Recentemente si è svolto a Roma un evento dimostrativo per informare, professionisti e ricercatori del settore inerente il rilievo strumentale, sulle recenti innovazioni che riguardano i laser scanner 3d. Il mercato della strumentazione dedicata al rilevamento architettonico e dell'ambiente, offre molte possibilità di scelta. Oggi i principali marchi producono strumenti sempre più efficienti ed ideati per ambiti di applicazione specifici, permettendo ai professionisti, la giusta scelta in termini di prestazioni ed economia.A demonstration event was recently held in Rome with the aim to inform professionals and researchers on recent innovations on instrumental survey related to the 3d laser scanner. The market of instrumentation for architectural survey offers many possibilitiesof choice. Today the major brands produce instruments that are more efficient and designed for specific areas of application, allowing the right choice in terms of performance and economy.

  1. Simulation-based investigation of the generality of Lyzenga's multispectral bathymetry formula in Case-1 coral reef water

    Science.gov (United States)

    Manessa, Masita Dwi Mandini; Kanno, Ariyo; Sagawa, Tatsuyuki; Sekine, Masahiko; Nurdin, Nurjannah

    2018-01-01

    Lyzenga's multispectral bathymetry formula has attracted considerable interest due to its simplicity. However, there has been little discussion of the effect that variation in optical conditions and bottom types-which commonly appears in coral reef environments-has on this formula's results. The present paper evaluates Lyzenga's multispectral bathymetry formula for a variety of optical conditions and bottom types. A noiseless dataset of above-water remote sensing reflectance from WorldView-2 images over Case-1 shallow coral reef water is simulated using a radiative transfer model. The simulation-based assessment shows that Lyzenga's formula performs robustly, with adequate generality and good accuracy, under a range of conditions. As expected, the influence of bottom type on depth estimation accuracy is far greater than the influence of other optical parameters, i.e., chlorophyll-a concentration and solar zenith angle. Further, based on the simulation dataset, Lyzenga's formula estimates depth when the bottom type is unknown almost as accurately as when the bottom type is known. This study provides a better understanding of Lyzenga's multispectral bathymetry formula under various optical conditions and bottom types.

  2. Radical advancement in multi-spectral imaging for autonomous vehicles (UAVs, UGVs, and UUVs) using active compensation.

    Energy Technology Data Exchange (ETDEWEB)

    Clark, Brian F.; Bagwell, Brett E.; Wick, David Victor

    2007-01-01

    The purpose of this LDRD was to demonstrate a compact, multi-spectral, refractive imaging systems using active optical compensation. Compared to a comparable, conventional lens system, our system has an increased operational bandwidth, provides for spectral selectivity and, non-mechanically corrects aberrations induced by the wavelength dependent properties of a passive refractive optical element (i.e. lens). The compact nature and low power requirements of the system lends itself to small platforms such as autonomous vehicles. In addition, the broad spectral bandwidth of our system would allow optimized performance for both day/night use, and the multi-spectral capability allows for spectral discrimination and signature identification.

  3. New Spectral Index for Detecting Wheat Yellow Rust Using Sentinel-2 Multispectral Imagery

    Directory of Open Access Journals (Sweden)

    Qiong Zheng

    2018-03-01

    Full Text Available Yellow rust is one of the most destructive diseases for winter wheat and has led to a significant decrease in winter wheat quality and yield. Identifying and monitoring yellow rust is of great importance for guiding agricultural production over large areas. Compared with traditional crop disease discrimination methods, remote sensing technology has proven to be a useful tool for accomplishing such a task at large scale. This study explores the potential of the Sentinel-2 Multispectral Instrument (MSI, a newly launched satellite with refined spatial resolution and three red-edge bands, for discriminating between yellow rust infection severities (i.e., healthy, slight, and severe in winter wheat. The corresponding simulative multispectral bands for the Sentinel-2 sensor were calculated by the sensor’s relative spectral response (RSR function based on the in situ hyperspectral data acquired at the canopy level. Three Sentinel-2 spectral bands, including B4 (Red, B5 (Re1, and B7 (Re3, were found to be sensitive bands using the random forest (RF method. A new multispectral index, the Red Edge Disease Stress Index (REDSI, which consists of these sensitive bands, was proposed to detect yellow rust infection at different severity levels. The overall identification accuracy for REDSI was 84.1% and the kappa coefficient was 0.76. Moreover, REDSI performed better than other commonly used disease spectral indexes for yellow rust discrimination at the canopy scale. The optimal threshold method was adopted for mapping yellow rust infection at regional scales based on realistic Sentinel-2 multispectral image data to further assess REDSI’s ability for yellow rust detection. The overall accuracy was 85.2% and kappa coefficient was 0.67, which was found through validation against a set of field survey data. This study suggests that the Sentinel-2 MSI has the potential for yellow rust discrimination, and the newly proposed REDSI has great robustness and

  4. New Spectral Index for Detecting Wheat Yellow Rust Using Sentinel-2 Multispectral Imagery.

    Science.gov (United States)

    Zheng, Qiong; Huang, Wenjiang; Cui, Ximin; Shi, Yue; Liu, Linyi

    2018-03-15

    Yellow rust is one of the most destructive diseases for winter wheat and has led to a significant decrease in winter wheat quality and yield. Identifying and monitoring yellow rust is of great importance for guiding agricultural production over large areas. Compared with traditional crop disease discrimination methods, remote sensing technology has proven to be a useful tool for accomplishing such a task at large scale. This study explores the potential of the Sentinel-2 Multispectral Instrument (MSI), a newly launched satellite with refined spatial resolution and three red-edge bands, for discriminating between yellow rust infection severities (i.e., healthy, slight, and severe) in winter wheat. The corresponding simulative multispectral bands for the Sentinel-2 sensor were calculated by the sensor's relative spectral response (RSR) function based on the in situ hyperspectral data acquired at the canopy level. Three Sentinel-2 spectral bands, including B4 (Red), B5 (Re1), and B7 (Re3), were found to be sensitive bands using the random forest (RF) method. A new multispectral index, the Red Edge Disease Stress Index (REDSI), which consists of these sensitive bands, was proposed to detect yellow rust infection at different severity levels. The overall identification accuracy for REDSI was 84.1% and the kappa coefficient was 0.76. Moreover, REDSI performed better than other commonly used disease spectral indexes for yellow rust discrimination at the canopy scale. The optimal threshold method was adopted for mapping yellow rust infection at regional scales based on realistic Sentinel-2 multispectral image data to further assess REDSI's ability for yellow rust detection. The overall accuracy was 85.2% and kappa coefficient was 0.67, which was found through validation against a set of field survey data. This study suggests that the Sentinel-2 MSI has the potential for yellow rust discrimination, and the newly proposed REDSI has great robustness and generalized ability

  5. Employing airborne multispectral digital imagery to map Brazilian pepper infestation in south Texas.

    Science.gov (United States)

    A study was conducted in south Texas to determine the feasibility of using airborne multispectral digital imagery for differentiating the invasive plant Brazilian pepper (Schinus terebinthifolius) from other cover types. Imagery obtained in the visible, near infrared, and mid infrared regions of th...

  6. MULTISPECTRAL PANSHARPENING APPROACH USING PULSE-COUPLED NEURAL NETWORK SEGMENTATION

    Directory of Open Access Journals (Sweden)

    X. J. Li

    2018-04-01

    Full Text Available The paper proposes a novel pansharpening method based on the pulse-coupled neural network segmentation. In the new method, uniform injection gains of each region are estimated through PCNN segmentation rather than through a simple square window. Since PCNN segmentation agrees with the human visual system, the proposed method shows better spectral consistency. Our experiments, which have been carried out for both suburban and urban datasets, demonstrate that the proposed method outperforms other methods in multispectral pansharpening.

  7. Digital data storage of core image using high resolution full color core scanner; Kokaizodo full color scanner wo mochiita core image no digital ka

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, W; Ujo, S; Osato, K; Takasugi, S [Geothermal Energy Research and Development Co. Ltd., Tokyo (Japan)

    1996-05-01

    This paper reports on digitization of core images by using a new type core scanner system. This system consists of a core scanner unit (equipped with a CCD camera), a personal computer and ancillary devices. This is a modification of the old type system, with measurable core length made to 100 cm/3 scans, and resolution enhanced to 5100 pixels/m (1024 pixels/m in the old type). The camera was changed to that of a color specification, and the A/D conversion was improved to 24-bit full color. As a result of carrying out a detail reproduction test on digital images of this core scanner, it was found that objects can be identified at a level of about the size of pixels constituting the image in the case when the best contrast is obtained between the objects and the background, and that in an evaluation test on visibility of concaves and convexes on core surface, reproducibility is not very good in large concaves and convexes. 2 refs., 6 figs.

  8. Radiation exposure and privacy concerns surrounding full-body scanners in airports

    Directory of Open Access Journals (Sweden)

    Julie Accardo

    2014-04-01

    Full Text Available Millions of people filter through airport security check points in the United States every year. These security checks, in response to the post 9/11 and 2009 “Underwear Bomber” terrorist threats, have become increasingly burdensome to the general public due to the wide spread deployment of “enhanced screening systems.” The enhanced screening systems that have generated the most controversy are the passenger “full-body scanners.” These systems enable airport security personnel to effectively detect contraband (often concealed under clothing without the physical contact necessitated by a strip search. The two types of full-body scanners (also known as Advanced Imaging Technology systems, used in airports in the United States and around the world are referred to as backscatter technology units and millimeter-wave technology units. Although their respective radiation emissions vary, both scanners serve the same purpose; that is, the detection of concealed metallic and non-metallic threats in the form of liquids, gels, plastics, etc. Although enhanced screening systems were deployed to further public safety efforts, they have also generated wide spread public concern. Specifically, these concerns address the potential of adverse health and privacy issues that may result from continued public exposure to full-body scanner systems.

  9. Advanced optical 3D scanners using DMD technology

    Science.gov (United States)

    Muenstermann, P.; Godding, R.; Hermstein, M.

    2017-02-01

    Optical 3D measurement techniques are state-of-the-art for highly precise, non-contact surface scanners - not only in industrial development, but also in near-production and even in-line configurations. The need for automated systems with very high accuracy and clear implementation of national precision standards is growing extremely due to expanding international quality guidelines, increasing production transparency and new concepts related to the demands of the fourth industrial revolution. The presentation gives an overview about the present technical concepts for optical 3D scanners and their benefit for customers and various different applications - not only in quality control, but also in design centers or in medical applications. The advantages of DMD-based systems will be discussed and compared to other approaches. Looking at today's 3D scanner market, there is a confusing amount of solutions varying from lowprice solutions to high end systems. Many of them are linked to a very special target group or to special applications. The article will clarify the differences of the approaches and will discuss some key features which are necessary to render optical measurement systems suitable for industrial environments. The paper will be completed by examples for DMDbased systems, e. g. RGB true-color systems with very high accuracy like the StereoScan neo of AICON 3D Systems. Typical applications and the benefits for customers using such systems are described.

  10. Measurement properties and usability of non-contact scanners for measuring transtibial residual limb volume.

    Science.gov (United States)

    Kofman, Rianne; Beekman, Anna M; Emmelot, Cornelis H; Geertzen, Jan H B; Dijkstra, Pieter U

    2018-06-01

    Non-contact scanners may have potential for measurement of residual limb volume. Different non-contact scanners have been introduced during the last decades. Reliability and usability (practicality and user friendliness) should be assessed before introducing these systems in clinical practice. The aim of this study was to analyze the measurement properties and usability of four non-contact scanners (TT Design, Omega Scanner, BioSculptor Bioscanner, and Rodin4D Scanner). Quasi experimental. Nine (geometric and residual limb) models were measured on two occasions, each consisting of two sessions, thus in total 4 sessions. In each session, four observers used the four systems for volume measurement. Mean for each model, repeatability coefficients for each system, variance components, and their two-way interactions of measurement conditions were calculated. User satisfaction was evaluated with the Post-Study System Usability Questionnaire. Systematic differences between the systems were found in volume measurements. Most of the variances were explained by the model (97%), while error variance was 3%. Measurement system and the interaction between system and model explained 44% of the error variance. Repeatability coefficient of the systems ranged from 0.101 (Omega Scanner) to 0.131 L (Rodin4D). Differences in Post-Study System Usability Questionnaire scores between the systems were small and not significant. The systems were reliable in determining residual limb volume. Measurement systems and the interaction between system and residual limb model explained most of the error variances. The differences in repeatability coefficient and usability between the four CAD/CAM systems were small. Clinical relevance If accurate measurements of residual limb volume are required (in case of research), modern non-contact scanners should be taken in consideration nowadays.

  11. A comparison of the accuracy of intraoral scanners using an intraoral environment simulator.

    Science.gov (United States)

    Park, Hye-Nan; Lim, Young-Jun; Yi, Won-Jin; Han, Jung-Suk; Lee, Seung-Pyo

    2018-02-01

    The aim of this study was to design an intraoral environment simulator and to assess the accuracy of two intraoral scanners using the simulator. A box-shaped intraoral environment simulator was designed to simulate two specific intraoral environments. The cast was scanned 10 times by Identica Blue (MEDIT, Seoul, South Korea), TRIOS (3Shape, Copenhagen, Denmark), and CS3500 (Carestream Dental, Georgia, USA) scanners in the two simulated groups. The distances between the left and right canines (D3), first molars (D6), second molars (D7), and the left canine and left second molar (D37) were measured. The distance data were analyzed by the Kruskal-Wallis test. The differences in intraoral environments were not statistically significant ( P >.05). Between intraoral scanners, statistically significant differences ( P Kruskal-Wallis test with regard to D3 and D6. No difference due to the intraoral environment was revealed. The simulator will contribute to the higher accuracy of intraoral scanners in the future.

  12. Inter laboratory comparison of industrial CT scanners

    DEFF Research Database (Denmark)

    Angel, Jais Andreas Breusch; Cantatore, Angela; De Chiffre, Leonardo

    2012-01-01

    In this report results from an intercomparison of industrial CT scanners are presented. Three audit items, similar to common industrial parts, were selected for circulation: a single polymer part with complex geometry (Item 1), a simple geometry part made of two polymers (Item 2) and a miniature...

  13. Get Mobile – The Smartphone Brain Scanner

    DEFF Research Database (Denmark)

    Stahlhut, Carsten; Stopczynski, Arkadiusz; Petersen, Michael Kai

    This demonstration will provide live-interaction with a smartphone brain scanner consisting of a low-cost wireless 14-channel EEG headset (Emotiv Epoc) and a mobile device. With our system it is possible to perform real-time functional brain imaging on a smartphone device, including stimulus...

  14. A PET scanner developed by CERN

    CERN Multimedia

    Laurent Guiraud

    1998-01-01

    This image shows a Position Emission Tomography (PET) scanner at the Hopital Cantonal Universitaire de Genève. Development of the multiwire proportional chamber at CERN in the mid-1970s was soon seen as a potential device for medical imaging. It is much more sensitive than previous devices and greatly reduced the dose of radiation received by the patient.

  15. NMR of geophysical drill cores with a mobile Halbach scanner

    International Nuclear Information System (INIS)

    Talnishnikh, E.

    2007-01-01

    This thesis is devoted to a mobile NMR with an improved Halbach scanner. This is a lightweight tube-shaped magnet with sensitive volume larger and a homogeneity of the magnetic field higher than the previous prototype version. The improved Halbach scanner is used for analysis of water-saturated drill cores and plugs with diameters up to 60 mm. To provide the analysis, the standard 1D technique with the CPMG sequence as well as 2D correlation experiments were successfully applied and adapted to study properties of fluid-saturated sediments. Afterwards the Halbach scanner was calibrated to fast non-destructive measurements of porosity, relaxation time distributions, and estimation of permeability. These properties can be calculated directly from the NMR data using the developed methodology. Any independent measurements of these properties with other methods are not needed. One of the main results of this work is the development of a new NMR on-line core scanner for measurements of porosity in long cylindrical and semi cylindrical drill cores. Also dedicated software was written to operate the NMR on-line core scanner. The physical background of this work is the study of the diffusion influence on transverse relaxation. The diffusion effect in the presence of internal gradients in porous media was probed by 1D and 2D experiments. The transverse relaxation time distributions obtained from 1D and from 2D experiments are comparable but different in fine details. Two new methodologies were developed based on the results of this study. First is the methodology quantifying the influence of diffusion in the internal gradients of water-saturated sediments on transverse relaxation from 2D correlation experiments. The second one is the correction of the permeability estimation from the NMR data taking in account the influence of the diffusion. Furthermore, PFG NMR technique was used to study restricted diffusion in the same kind of samples. Preliminary results are reported

  16. NMR of geophysical drill cores with a mobile Halbach scanner

    Energy Technology Data Exchange (ETDEWEB)

    Talnishnikh, E.

    2007-08-21

    This thesis is devoted to a mobile NMR with an improved Halbach scanner. This is a lightweight tube-shaped magnet with sensitive volume larger and a homogeneity of the magnetic field higher than the previous prototype version. The improved Halbach scanner is used for analysis of water-saturated drill cores and plugs with diameters up to 60 mm. To provide the analysis, the standard 1D technique with the CPMG sequence as well as 2D correlation experiments were successfully applied and adapted to study properties of fluid-saturated sediments. Afterwards the Halbach scanner was calibrated to fast non-destructive measurements of porosity, relaxation time distributions, and estimation of permeability. These properties can be calculated directly from the NMR data using the developed methodology. Any independent measurements of these properties with other methods are not needed. One of the main results of this work is the development of a new NMR on-line core scanner for measurements of porosity in long cylindrical and semi cylindrical drill cores. Also dedicated software was written to operate the NMR on-line core scanner. The physical background of this work is the study of the diffusion influence on transverse relaxation. The diffusion effect in the presence of internal gradients in porous media was probed by 1D and 2D experiments. The transverse relaxation time distributions obtained from 1D and from 2D experiments are comparable but different in fine details. Two new methodologies were developed based on the results of this study. First is the methodology quantifying the influence of diffusion in the internal gradients of water-saturated sediments on transverse relaxation from 2D correlation experiments. The second one is the correction of the permeability estimation from the NMR data taking in account the influence of the diffusion. Furthermore, PFG NMR technique was used to study restricted diffusion in the same kind of samples. Preliminary results are reported

  17. Multispectral imaging as a potential tool for seed health testing of spinach (Spinacia oleracea L.)

    DEFF Research Database (Denmark)

    Olesen, M. Halkjaer; Carstensen, Jens Michael; Boelt, B.

    2011-01-01

    Seed health tests are time consuming and require substantial training for characterization of pathogenic fungi on seed. A new approach to use a multispectral vision system for identifying surface properties of different fungal infections has been tested in spinach (Spinacia oleracea L.) at Aarhus...... University. Our study demonstrates that multispectral imaging with wavelengths ranging from 395-970 nm can be used to distinguish between uninfected spinach seeds and seeds infected with Verticillium spp., Fusarium spp., Stemphylium botryosum, Cladosporium spp. and Alternaria alternata. Analytical separation...... based on mean pixel intensity, Canonical Discriminant Analysis (CDA) and classification by Jeffries-Matusita (JM) distance illustrates that a combination of Near Infrared spectra (NIR) and Visual spectra (VIS) is able to identify uninfected seeds from infected seeds ranging from 80-100%. Classification...

  18. Comparison of a multispectral vision system and a colorimeter for the assessment of meat color

    DEFF Research Database (Denmark)

    Trinderup, Camilla Himmelstrup; Dahl, Anders Bjorholm; Jensen, Kirsten

    2015-01-01

    The color assessment ability of a multispectral vision system is investigated by a comparison study with color measurements from a traditional colorimeter. The experiment involves fresh and processed meat samples. Meat is a complex material; heterogeneous with varying scattering and reflectance...... are equally capable of measuring color. Moreover the vision system provides a more color rich assessment of fresh meat samples with a glossier surface, than the colorimeter. Careful studies of the different sources of variation enable an assessment of the order of magnitude of the variability between methods...... accounting for other sources of variation leading to the conclusion that color assessment using a multispectral vision system is superior to traditional colorimeter assessments. (C) 2014 Elsevier Ltd. All rights reserved....

  19. Development of Monte Carlo simulations to provide scanner-specific organ dose coefficients for contemporary CT

    Science.gov (United States)

    Jansen, Jan T. M.; Shrimpton, Paul C.

    2016-07-01

    The ImPACT (imaging performance assessment of CT scanners) CT patient dosimetry calculator is still used world-wide to estimate organ and effective doses (E) for computed tomography (CT) examinations, although the tool is based on Monte Carlo calculations reflecting practice in the early 1990’s. Subsequent developments in CT scanners, definitions of E, anthropomorphic phantoms, computers and radiation transport codes, have all fuelled an urgent need for updated organ dose conversion factors for contemporary CT. A new system for such simulations has been developed and satisfactorily tested. Benchmark comparisons of normalised organ doses presently derived for three old scanners (General Electric 9800, Philips Tomoscan LX and Siemens Somatom DRH) are within 5% of published values. Moreover, calculated normalised values of CT Dose Index for these scanners are in reasonable agreement (within measurement and computational uncertainties of  ±6% and  ±1%, respectively) with reported standard measurements. Organ dose coefficients calculated for a contemporary CT scanner (Siemens Somatom Sensation 16) demonstrate potential deviations by up to around 30% from the surrogate values presently assumed (through a scanner matching process) when using the ImPACT CT Dosimetry tool for newer scanners. Also, illustrative estimates of E for some typical examinations and a range of anthropomorphic phantoms demonstrate the significant differences (by some 10’s of percent) that can arise when changing from the previously adopted stylised mathematical phantom to the voxel phantoms presently recommended by the International Commission on Radiological Protection (ICRP), and when following the 2007 ICRP recommendations (updated from 1990) concerning tissue weighting factors. Further simulations with the validated dosimetry system will provide updated series of dose coefficients for a wide range of contemporary scanners.

  20. SPEKTROP DPU: optoelectronic platform for fast multispectral imaging

    Science.gov (United States)

    Graczyk, Rafal; Sitek, Piotr; Stolarski, Marcin

    2010-09-01

    In recent years it easy to spot and increasing need of high-quality Earth imaging in airborne and space applications. This is due fact that government and local authorities urge for up to date topological data for administrative purposes. On the other hand, interest in environmental sciences, push for ecological approach, efficient agriculture and forests management are also heavily supported by Earth images in various resolutions and spectral ranges. "SPEKTROP DPU: Opto-electronic platform for fast multi-spectral imaging" paper describes architectural datails of data processing unit, part of universal and modular platform that provides high quality imaging functionality in aerospace applications.

  1. COMPARATIVE ANALYSIS OF TRANSPORT AIRCRAFT, BACKROUND FOR SHORT/ MEDIUM COURIER TRANSPORT AIRCRAFT PROCUREMENT

    Directory of Open Access Journals (Sweden)

    Matei POPA

    2010-03-01

    Full Text Available In accordance with Air Force requirements, the comparative analysis of short/medium transport aircraft comes to sustain procurement decision of short/medium transport aircraft. This paper presents, in short, the principles and the results of the comparative analysis for short/medium military transport aircraft.

  2. Kite aerial photography for low-cost, ultra-high spatial resolution multi-spectral mapping of intertidal landscapes.

    Directory of Open Access Journals (Sweden)

    Mitch Bryson

    Full Text Available Intertidal ecosystems have primarily been studied using field-based sampling; remote sensing offers the ability to collect data over large areas in a snapshot of time that could complement field-based sampling methods by extrapolating them into the wider spatial and temporal context. Conventional remote sensing tools (such as satellite and aircraft imaging provide data at limited spatial and temporal resolutions and relatively high costs for small-scale environmental science and ecologically-focussed studies. In this paper, we describe a low-cost, kite-based imaging system and photogrammetric/mapping procedure that was developed for constructing high-resolution, three-dimensional, multi-spectral terrain models of intertidal rocky shores. The processing procedure uses automatic image feature detection and matching, structure-from-motion and photo-textured terrain surface reconstruction algorithms that require minimal human input and only a small number of ground control points and allow the use of cheap, consumer-grade digital cameras. The resulting maps combine imagery at visible and near-infrared wavelengths and topographic information at sub-centimeter resolutions over an intertidal shoreline 200 m long, thus enabling spatial properties of the intertidal environment to be determined across a hierarchy of spatial scales. Results of the system are presented for an intertidal rocky shore at Jervis Bay, New South Wales, Australia. Potential uses of this technique include mapping of plant (micro- and macro-algae and animal (e.g. gastropods assemblages at multiple spatial and temporal scales.

  3. Kite aerial photography for low-cost, ultra-high spatial resolution multi-spectral mapping of intertidal landscapes.

    Science.gov (United States)

    Bryson, Mitch; Johnson-Roberson, Matthew; Murphy, Richard J; Bongiorno, Daniel

    2013-01-01

    Intertidal ecosystems have primarily been studied using field-based sampling; remote sensing offers the ability to collect data over large areas in a snapshot of time that could complement field-based sampling methods by extrapolating them into the wider spatial and temporal context. Conventional remote sensing tools (such as satellite and aircraft imaging) provide data at limited spatial and temporal resolutions and relatively high costs for small-scale environmental science and ecologically-focussed studies. In this paper, we describe a low-cost, kite-based imaging system and photogrammetric/mapping procedure that was developed for constructing high-resolution, three-dimensional, multi-spectral terrain models of intertidal rocky shores. The processing procedure uses automatic image feature detection and matching, structure-from-motion and photo-textured terrain surface reconstruction algorithms that require minimal human input and only a small number of ground control points and allow the use of cheap, consumer-grade digital cameras. The resulting maps combine imagery at visible and near-infrared wavelengths and topographic information at sub-centimeter resolutions over an intertidal shoreline 200 m long, thus enabling spatial properties of the intertidal environment to be determined across a hierarchy of spatial scales. Results of the system are presented for an intertidal rocky shore at Jervis Bay, New South Wales, Australia. Potential uses of this technique include mapping of plant (micro- and macro-algae) and animal (e.g. gastropods) assemblages at multiple spatial and temporal scales.

  4. A dedicated breast-PET/CT scanner: Evaluation of basic performance characteristics.

    Science.gov (United States)

    Raylman, Raymond R; Van Kampen, Will; Stolin, Alexander V; Gong, Wenbo; Jaliparthi, Gangadhar; Martone, Peter F; Smith, Mark F; Sarment, David; Clinthorne, Neal H; Perna, Mark

    2018-04-01

    Application of advanced imaging techniques, such as PET and x ray CT, can potentially improve detection of breast cancer. Unfortunately, both modalities have challenges in the detection of some lesions. The combination of the two techniques, however, could potentially lead to an overall improvement in diagnostic breast imaging. The purpose of this investigation is to test the basic performance of a new dedicated breast-PET/CT. The PET component consists of a rotating pair of detectors. Its performance was evaluated using the NEMA NU4-2008 protocols. The CT component utilizes a pulsed x ray source and flat panel detector mounted on the same gantry as the PET scanner. Its performance was assessed using specialized phantoms. The radiation dose to a breast during CT imaging was explored by the measurement of free-in-air kerma and air kerma measured at the center of a 16 cm-diameter PMMA cylinder. Finally, the combined capabilities of the system were demonstrated by imaging of a micro-hot-rod phantom. Overall, performance of the PET component is comparable to many pre-clinical and other dedicated breast-PET scanners. Its spatial resolution is 2.2 mm, 5 mm from the center of the scanner using images created with the single-sliced-filtered-backprojection algorithm. Peak NECR is 24.6 kcps; peak sensitivity is 1.36%; the scatter fraction is 27%. Spatial resolution of the CT scanner is 1.1 lp/mm at 10% MTF. The free-in-air kerma is 2.33 mGy, while the PMMA-air kerma is 1.24 mGy. Finally, combined imaging of a micro-hot-rod phantom illustrated the potential utility of the dual-modality images produced by the system. The basic performance characteristics of a new dedicated breast-PET/CT scanner are good, demonstrating that its performance is similar to current dedicated PET and CT scanners. The potential value of this system is the capability to produce combined duality-modality images that could improve detection of breast disease. The next stage in development of this system

  5. SOLAR AIRCRAFT DESIGN

    OpenAIRE

    RAHMATI, Sadegh; GHASED, Amir

    2015-01-01

    Abstract. Generally domain Aircraft uses conventional fuel. These fuel having limited life, high cost and pollutant. Also nowadays price of petrol and other fuels are going to be higher, because of scarcity of those fuels. So there is great demand of use of non-exhaustible unlimited source of energy like solar energy. Solar aircraft is one of the ways to utilize solar energy. Solar aircraft uses solar panel to collect the solar radiation for immediate use but it also store the remaining part ...

  6. Experimental characterization of the Clear-PEM scanner spectrometric performance

    Energy Technology Data Exchange (ETDEWEB)

    Bugalho, R; Carrico, B; Ferreira, C S; Frade, M; Ferreira, M; Moura, R; Ortigao, C; Pinheiro, J F; Rodrigues, P; Rolo, I; Silva, J C; Trindade, A; Varela, J [Laboratorio de Instrumentacao e Fisica Experimental de Particulas (LIP), Av. Elias Garcia 14-1, 1000-149 Lisboa (Portugal)], E-mail: frade@lip.pt

    2009-10-15

    In the framework of the Clear-PEM project for the construction of a high-resolution and high-specificity scanner for breast cancer imaging, a Positron Emission Mammography tomograph has been developed and installed at the Instituto Portugues de Oncologia do Porto hospital. The Clear-PEM scanner is mainly composed by two planar detector heads attached to a robotic arm, trigger/data acquisition electronics system and computing servers. The detector heads hold crystal matrices built from 2 x 2 x 20 mm{sup 3} LYSO:Ce crystals readout by Hamamatsu S8550 APD arrays. The APDs are optically coupled to both ends of the 6144 crystals in order to extract the DOI information for each detected event. Each one of 12288 APD's pixels is read and controlled by Application Specific Integrated Circuits water-cooled by an external cooling unit. The Clear-PEM frontend boards innovative design results in a unprecedented integration of the crystal matrices, APDs and ASICs, making Clear-PEM the PET scanner with the highest number of APD pixels ever integrated so far. In this paper, the scanner's main technical characteristics, calibration strategies and the first spectrometric performance evaluation in a clinical environment are presented. The first commissioning results show 99.7% active channels, which, after calibration, have inter-pixel and absolute gain distributions with dispersions of, respectively, 12.2% and 15.3%, demonstrating that despite the large number of channels, the system is uniform. The mean energy resolution at 511 keV is of 15.9%, with a 8.8% dispersion, and the mean C{sub DOI}{sup -1} is 5.9%/mm, with a 7.8% dispersion. The coincidence time resolution, at 511 keV, for a energy window between 400 and 600 keV, is 5.2 ns FWHM.

  7. Using Non-Invasive Multi-Spectral Imaging to Quantitatively Assess Tissue Vasculature

    Energy Technology Data Exchange (ETDEWEB)

    Vogel, A; Chernomordik, V; Riley, J; Hassan, M; Amyot, F; Dasgeb, B; Demos, S G; Pursley, R; Little, R; Yarchoan, R; Tao, Y; Gandjbakhche, A H

    2007-10-04

    This research describes a non-invasive, non-contact method used to quantitatively analyze the functional characteristics of tissue. Multi-spectral images collected at several near-infrared wavelengths are input into a mathematical optical skin model that considers the contributions from different analytes in the epidermis and dermis skin layers. Through a reconstruction algorithm, we can quantify the percent of blood in a given area of tissue and the fraction of that blood that is oxygenated. Imaging normal tissue confirms previously reported values for the percent of blood in tissue and the percent of blood that is oxygenated in tissue and surrounding vasculature, for the normal state and when ischemia is induced. This methodology has been applied to assess vascular Kaposi's sarcoma lesions and the surrounding tissue before and during experimental therapies. The multi-spectral imaging technique has been combined with laser Doppler imaging to gain additional information. Results indicate that these techniques are able to provide quantitative and functional information about tissue changes during experimental drug therapy and investigate progression of disease before changes are visibly apparent, suggesting a potential for them to be used as complementary imaging techniques to clinical assessment.

  8. Internal calibration for equipment AR-2000 radio-TLC imaging scanner

    International Nuclear Information System (INIS)

    Yayan Tahyan; Enny Lestari; Endang Sarmini; Sri Setiyowati

    2013-01-01

    Testing quality system ISO / IEC 17025:2008 requires that equipment and software used in testing have to give good precision and accuracy. Internal calibration is needed to assess the precision and accuracy of the testing device. The equipment AR-2000 radio-TLC Imaging Scanner in the field of nuclear medicine used in radiochemical purity testing. Determined with precision by the coefficient of variation (% CV) and accuracy, while the deviation value based on internal calibration of the retention factor value reading three peaks Carbon-standard sources mentioned that the reference 14. Standard value % CV ≤ 15% and ≤ 3 mm deviation value. Internal calibration results show that the tool AR-2000 radio-TLC Imaging Scanner provides precision values with a mean coefficient of variation (% CV) and accuracy gained 3.1% for the peak value of unity deviation of 1.79 mm, 0.39 mm and the second peak of the peak three 0.55 mm. This suggests that AR-2000 radio tool-TLC Imaging Scanner in good condition. (author)

  9. Comparative Performance Analysis of Different Fingerprint Biometric Scanners for Patient Matching.

    Science.gov (United States)

    Kasiiti, Noah; Wawira, Judy; Purkayastha, Saptarshi; Were, Martin C

    2017-01-01

    Unique patient identification within health services is an operational challenge in healthcare settings. Use of key identifiers, such as patient names, hospital identification numbers, national ID, and birth date are often inadequate for ensuring unique patient identification. In addition approximate string comparator algorithms, such as distance-based algorithms, have proven suboptimal for improving patient matching, especially in low-resource settings. Biometric approaches may improve unique patient identification. However, before implementing the technology in a given setting, such as health care, the right scanners should be rigorously tested to identify an optimal package for the implementation. This study aimed to investigate the effects of factors such as resolution, template size, and scan capture area on the matching performance of different fingerprint scanners for use within health care settings. Performance analysis of eight different scanners was tested using the demo application distributed as part of the Neurotech Verifinger SDK 6.0.

  10. A 3D airborne ultrasound scanner

    Science.gov (United States)

    Capineri, L.; Masotti, L.; Rocchi, S.

    1998-06-01

    This work investigates the feasibility of an ultrasound scanner designed to reconstruct three-dimensional profiles of objects in air. There are many industrial applications in which it is important to obtain quickly and accurately the digital reconstruction of solid objects with contactless methods. The final aim of this project was the profile reconstruction of shoe lasts in order to eliminate the mechanical tracers from the reproduction process of shoe prototypes. The feasibility of an ultrasonic scanner was investigated in laboratory conditions on wooden test objects with axial symmetry. A bistatic system based on five airborne polyvinylidenedifluoride (PVDF) transducers was mechanically moved to emulate a cylindrical array transducer that can host objects of maximum width and height 20 cm and 40 cm respectively. The object reconstruction was based on a simplified version of the synthetic aperture focusing technique (SAFT): the time of flight (TOF) of the first in time echo for each receiving transducer was taken into account, a coarse spatial sampling of the ultrasonic field reflected on the array transducer was delivered and the reconstruction algorithm was based on the ellipsoidal backprojection. Measurements on a wooden cone section provided submillimetre accuracy in a controlled environment.

  11. Use of ERTS data for a multidisciplinary analysis of Michigan resources. [forests, agriculture, soils, and landforms

    Science.gov (United States)

    Andersen, A. L.; Myers, W. L.; Safir, G.; Whiteside, E. P. (Principal Investigator)

    1974-01-01

    The author has identified the following significant results. The results of this investigation of ratioing simulated ERTS spectral bands and several non-ERTS bands (all collected by an airborne multispectral scanner) indicate that significant terrain information is available from band-ratio images. Ratio images, which are based on the relative spectral changes which occur from one band to another, are useful for enhancing differences and aiding the image interpreter in identifying and mapping the distribution of such terrain elements as seedling crops, all bare soil, organic soil, mineral soil, forest and woodlots, and marsh areas. In addition, the ratio technique may be useful for computer processing to obtain recognition images of large areas at lower costs than with statistical decision rules. The results of this study of ratio processing of aircraft MSS data will be useful for future processing and evaluation of ERTS-1 data for soil and landform studies. Additionally, the results of ratioing spectral bands other than those currently collected by ERTS-1 suggests that some other bands (particularly a thermal band) would be useful in future satellites.

  12. [Multispectral Radiation Algorithm Based on Emissivity Model Constraints for True Temperature Measurement].

    Science.gov (United States)

    Liang, Mei; Sun, Xiao-gang; Luan, Mei-sheng

    2015-10-01

    Temperature measurement is one of the important factors for ensuring product quality, reducing production cost and ensuring experiment safety in industrial manufacture and scientific experiment. Radiation thermometry is the main method for non-contact temperature measurement. The second measurement (SM) method is one of the common methods in the multispectral radiation thermometry. However, the SM method cannot be applied to on-line data processing. To solve the problems, a rapid inversion method for multispectral radiation true temperature measurement is proposed and constraint conditions of emissivity model are introduced based on the multispectral brightness temperature model. For non-blackbody, it can be drawn that emissivity is an increasing function in the interval if the brightness temperature is an increasing function or a constant function in a range and emissivity satisfies an inequality of emissivity and wavelength in that interval if the brightness temperature is a decreasing function in a range, according to the relationship of brightness temperatures at different wavelengths. The construction of emissivity assumption values is reduced from multiclass to one class and avoiding the unnecessary emissivity construction with emissivity model constraint conditions on the basis of brightness temperature information. Simulation experiments and comparisons for two different temperature points are carried out based on five measured targets with five representative variation trends of real emissivity. decreasing monotonically, increasing monotonically, first decreasing with wavelength and then increasing, first increasing and then decreasing and fluctuating with wavelength randomly. The simulation results show that compared with the SM method, for the same target under the same initial temperature and emissivity search range, the processing speed of the proposed algorithm is increased by 19.16%-43.45% with the same precision and the same calculation results.

  13. Aircraft operations management manual

    Science.gov (United States)

    1992-01-01

    The NASA aircraft operations program is a multifaceted, highly diverse entity that directly supports the agency mission in aeronautical research and development, space science and applications, space flight, astronaut readiness training, and related activities through research and development, program support, and mission management aircraft operations flights. Users of the program are interagency, inter-government, international, and the business community. This manual provides guidelines to establish policy for the management of NASA aircraft resources, aircraft operations, and related matters. This policy is an integral part of and must be followed when establishing field installation policy and procedures covering the management of NASA aircraft operations. Each operating location will develop appropriate local procedures that conform with the requirements of this handbook. This manual should be used in conjunction with other governing instructions, handbooks, and manuals.

  14. Shielding design for testing room of large container scanner

    International Nuclear Information System (INIS)

    Liu Yisi; Miao Qitian; Zhou Liye

    1997-01-01

    Testing facility for large container scanner is a most advanced anti-smuggle tool. The X-ray scanning principle is adopted in this system. The X-ray was collimated a ted as a fan-shape beam. The accelerator only supplies the ray beam when the container is scanned. The irradiation time is less than one minute per test. The X-ray burst irradiation and highly collimated a ted scanning beam of this system is different from the common industrial irradiation accelerator. The shielding design of the 1:1 large container scanner introduced has better collimation level because of tri-collimation. The irradiation dose is less than 150 μGy per test, which is obviously lower than importations

  15. Accuracy of 3-dimensional curvilinear measurements on digital models with intraoral scanners.

    Science.gov (United States)

    Mack, Spencer; Bonilla, Tammy; English, Jeryl D; Cozad, Benjamin; Akyalcin, Sercan

    2017-09-01

    Our objectives were to evaluate and compare the digital dental models generated from 2 commercial intraoral scanners with manual measurements when performing 3-dimensional surface measurements along a curved line (curvilinear). Dry mandibles (n = 61) with intact dentition were used. The mandibles were digitized using 2 chair-side intraoral scanners: Cadent iTero (Align Technology, San Jose, Calif) and Lythos Digital Impression system (Ormco, Orange, Calif). Digitized 3-dimensional models were converted to individual stereolithography files and used with commercial software to obtain the curvilinear measurements. Manual measurements were carried out directly on the mandibular teeth. Measurements were made on different locations on the dental arch in various directions. One-sample t tests and linear regression analyses were performed. To further graphically examine the accuracy between the different methods, Bland-Altman plots were computed. The level of significance was set at P 0.05). Bland-Altman analysis showed no fixed bias of 1 approach vs the other, and random errors were detected in all comparisons. Although the mean biases of the digital models obtained by the iTero and Lythos scanners, when compared with direct caliper measurements, were low, the comparison of the 2 intraoral scanners yielded the lowest mean bias. No comparison displayed statistical significance for the t scores; this indicated the absence of proportional bias in these comparisons. The intraoral scanners tested in this study produced digital dental models that were comparatively accurate when performing direct surface measurements along a curved line in 3 dimensions. Copyright © 2017 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  16. Multispectral analysis tools can increase utility of RGB color images in histology

    Science.gov (United States)

    Fereidouni, Farzad; Griffin, Croix; Todd, Austin; Levenson, Richard

    2018-04-01

    Multispectral imaging (MSI) is increasingly finding application in the study and characterization of biological specimens. However, the methods typically used come with challenges on both the acquisition and the analysis front. MSI can be slow and photon-inefficient, leading to long imaging times and possible phototoxicity and photobleaching. The resulting datasets can be large and complex, prompting the development of a number of mathematical approaches for segmentation and signal unmixing. We show that under certain circumstances, just three spectral channels provided by standard color cameras, coupled with multispectral analysis tools, including a more recent spectral phasor approach, can efficiently provide useful insights. These findings are supported with a mathematical model relating spectral bandwidth and spectral channel number to achievable spectral accuracy. The utility of 3-band RGB and MSI analysis tools are demonstrated on images acquired using brightfield and fluorescence techniques, as well as a novel microscopy approach employing UV-surface excitation. Supervised linear unmixing, automated non-negative matrix factorization and phasor analysis tools all provide useful results, with phasors generating particularly helpful spectral display plots for sample exploration.

  17. Conceptual design of high speed supersonic aircraft: A brief review on SR-71 (Blackbird) aircraft

    Science.gov (United States)

    Xue, Hui; Khawaja, H.; Moatamedi, M.

    2014-12-01

    The paper presents the conceptual design of high-speed supersonic aircraft. The study focuses on SR-71 (Blackbird) aircraft. The input to the conceptual design is a mission profile. Mission profile is a flight profile of the aircraft defined by the customer. This paper gives the SR-71 aircraft mission profile specified by US air force. Mission profile helps in defining the attributes the aircraft such as wing profile, vertical tail configuration, propulsion system, etc. Wing profile and vertical tail configurations have direct impact on lift, drag, stability, performance and maneuverability of the aircraft. A propulsion system directly influences the performance of the aircraft. By combining the wing profile and the propulsion system, two important parameters, known as wing loading and thrust to weight ratio can be calculated. In this work, conceptual design procedure given by D. P. Raymer (AIAA Educational Series) is applied to calculate wing loading and thrust to weight ratio. The calculated values are compared against the actual values of the SR-71 aircraft. Results indicates that the values are in agreement with the trend of developments in aviation.

  18. Near-infrared multispectral photoacoustic microscopy using a graded-index fiber amplifier

    Directory of Open Access Journals (Sweden)

    Takashi Buma

    2016-09-01

    Full Text Available We demonstrate optical resolution photoacoustic microscopy (OR-PAM of lipid-rich tissue using a multi-wavelength pulsed laser based on nonlinear fiber optics. 1047 nm laser pulses are converted to 1098, 1153, 1215, and 1270 nm pulses via stimulated Raman scattering in a graded-index multimode fiber. Multispectral PAM of a lipid phantom is demonstrated with our low-cost and simple technique.

  19. Study on a high resolution positron emission tomography scanner for brain study

    International Nuclear Information System (INIS)

    Nohara, N.; Tomitani, T.; Yamamoto, M.; Murayama, H.; Tanaka, E.

    1990-01-01

    The spatial resolution of positron emission tomography (PET) scanners is usually limited by the finite size of crystals such as bismuth germanate (BGO). To attain high resolution as well as high sensitivity, it is essential to use a large number of small BGO crystals arranged in close-packing on circular rings. In developing high resolution PET scanners, however, there are two physical factors limiting the spatial resolution. One is the finite range of positrons before annihilation and the other the deviation from 180 degrees of annihilation photons. The effect of the factors on the spatial resolution has been evaluated for positron-emitting sources as a function of detector ring radius. A high resolution PET scanner has been developed for brain study, aiming to have spatial resolutions as high as less than 4-mm FWHM in tomographic plane and less than 6-mm FWHM in axial direction at the detector ring center. For the goal of the high resolutions a multi-segment type of photomultiplier tubes has been specially designed and developed, which allows one tube to be directly coupled by four BGO crystals. The scanner consists of five detector rings of 47-cm in diameter, using all 1200 BGO crystals each measuring 5 mm x 12 mm x 30 mm. The scanner provides simultaneous 9 images by combination of in-plane and cross-plane, offering a 24-cm dia. x7.4-cm field-of-view. Physical performance of the scanner was investigated. At the ring center, the spatial resolution in the tomographic plane was measured to be 3.5-mm FWHM. The axial resolution was measured to be 5.7-mm FWHM for in-plane and 5.3-mm FWHM for cross-plane. Sensitivity for a 20-cm dia. uniform source was measured to be 9.5 kcps/μCi/ml for in-plane and 15.3 kcps/μCi/ml for cross-plane. (J.P.N.)

  20. Investigating the Potential of Using the Spatial and Spectral Information of Multispectral LiDAR for Object Classification

    Directory of Open Access Journals (Sweden)

    Wei Gong

    2015-09-01

    Full Text Available The abilities of multispectral LiDAR (MSL as a new high-potential active instrument for remote sensing have not been fully revealed. This study demonstrates the potential of using the spectral and spatial features derived from a novel MSL to discriminate surface objects. Data acquired with the MSL include distance information and the intensities of four wavelengths at 556, 670, 700, and 780 nm channels. A support vector machine was used to classify diverse objects in the experimental scene into seven types: wall, ceramic pots, Cactaceae, carton, plastic foam block, and healthy and dead leaves of E. aureum. Different features were used during classification to compare the performance of different detection systems. The spectral backscattered reflectance of one wavelength and distance represented the features from an equivalent single-wavelength LiDAR system; reflectance of the four wavelengths represented the features from an equivalent multispectral image with four bands. Results showed that the overall accuracy of using MSL data was as high as 88.7%, this value was 9.8%–39.2% higher than those obtained using a single-wavelength LiDAR, and 4.2% higher than for multispectral image.

  1. Erosion can't hide from laser scanner

    International Nuclear Information System (INIS)

    Konstant, D.A.

    1991-01-01

    Particles of topsoil blown by wind will bounce along the soil surface and finally escape a field, leaving it less able to support crops. Water will wash away valuable topsoil and nutrients. And how rough the soil surface is influences whether the soil will erode. Until now, soil scientists have had no suitable technique to measure soil roughness - or microtopography - on the small scale. ARS soil scientists Joe M. Bradford and Chi-hua Huang, of the National Soil Erosion Research Laboratory in West Lafayette, Indiana, have developed a portable scanner that can. It measures the tiny ridges left in the soil by tilling or clods of soil particles that clump together naturally. What does the scanner do? It measures soil elevation by shining a low-power laser beam onto the surface and detecting the position of the laser spot reflected from the soil with a 35-mm camera. In place of film, the scanner camera uses electronic circuitry somewhat similar to that in a video camera to transmit the spot's position to a small computer about 30,000 times a minute. The laser and camera are mounted on the frame of a motor-driven carriage. The computer controls the carriage movement. At the end of a scan, a microtopographic map is stored in the computer. Scientists can analyze it immediately and can compare it to previous maps to see whether erosion has occurred

  2. Development of the Shimadzu computed tomographic scanner SCT-200N

    International Nuclear Information System (INIS)

    Ishihara, Hiroshi; Yamaoka, Nobuyuki; Saito, Masahiro

    1982-01-01

    The Shimadzu Computed Tomographic Scanner SCT-200N has been developed as an ideal CT scanner for diagnosing the head and spine. Due to the large aperture, moderate scan time and the Zoom Scan Mode, any part of the body can be scanned. High quality image can be obtained by adopting the precisely stabilized X-ray unit and densely packed array of 64-detectors. As for its operation, capability of computed radiography (CR) prior to patient positioning and real time reconstruction ensure efficient patient through-put. Details of the SCT-200N are described in this paper. (author)

  3. Solar thermal aircraft

    Science.gov (United States)

    Bennett, Charles L.

    2007-09-18

    A solar thermal powered aircraft powered by heat energy from the sun. A heat engine, such as a Stirling engine, is carried by the aircraft body for producing power for a propulsion mechanism, such as a propeller. The heat engine has a thermal battery in thermal contact with it so that heat is supplied from the thermal battery. A solar concentrator, such as reflective parabolic trough, is movably connected to an optically transparent section of the aircraft body for receiving and concentrating solar energy from within the aircraft. Concentrated solar energy is collected by a heat collection and transport conduit, and heat transported to the thermal battery. A solar tracker includes a heliostat for determining optimal alignment with the sun, and a drive motor actuating the solar concentrator into optimal alignment with the sun based on a determination by the heliostat.

  4. Multi-spectral and fluorescence diffuse optical tomography of breast cancer

    Science.gov (United States)

    Corlu, Alper

    Multi-spectral and fluorescence diffuse optical tomography (DOT) techniques are explored and applied to image human breast cancer in vivo. Image reconstruction algorithms that utilize first and second order gradient information are described in detail. Breast DOT requires large computational memory and long run times. To this end, parallel computation techniques were developed appropriate to each reconstruction algorithm. A parallel plate DOT instrument developed for breast cancer imaging is described. The system relies heavily on continuous-wave (CW) transmission measurements and utilizes frequency domain (FD) measurements on the reemission side. However, traditional DOT image reconstruction methods based on CW measurements fail to separate tissue absorption and scattering uniquely. In this manuscript, multi-spectral DOT is shown to be capable of minimizing cross-talk and retrieving spectral parameters almost uniquely when the measurement wavelengths are optimized. A theoretical framework to select optimum wavelengths is provided, and tested with computer simulations. Results from phantom spectroscopy experiments and in vivo patient measurements support the notion that multi-spectral methods are superior to traditional DOT image reconstruction schemes. The same breast DOT instrument is improved and utilized to obtain the first in vivo images of human breast cancer based on fluorescence DOT (FDOT). To this end the fluorophore Indocyanine Green (ICG) is injected intravenously and fluorescence excitation and detection are accomplished in the soft-compression, parallel-plane, transmission geometry using laser sources at 786 nm and spectrally filtered CCD detection. Careful phantom and in vivo measurements are carried on to assure that the signals are due to ICG fluorescence, rather than tissue autofluorescence and excitation light leakage. An in vivo measurement protocol is designed to maximize the ICG contrast by acquiring full fluorescence tomographic scan during

  5. Digital Data Matrix Scanner Developnent At Marshall Space Flight Center

    Science.gov (United States)

    2004-01-01

    Research at NASA's Marshall Space Flight Center has resulted in a system for reading hidden identification codes using a hand-held magnetic scanner. It's an invention that could help businesses improve inventory management, enhance safety, improve security, and aid in recall efforts if defects are discovered. Two-dimensional Data Matrix symbols consisting of letters and numbers permanently etched on items for identification and resembling a small checkerboard pattern are more efficient and reliable than traditional bar codes, and can store up to 100 times more information. A team led by Fred Schramm of the Marshall Center's Technology Transfer Department, in partnership with PRI,Torrance, California, has developed a hand-held device that can read this special type of coded symbols, even if covered by up to six layers of paint. Before this new technology was available, matrix symbols were read with optical scanners, and only if the codes were visible. This latest improvement in digital Data Matrix technologies offers greater flexibility for businesses and industries already using the marking system. Paint, inks, and pastes containing magnetic properties are applied in matrix symbol patterns to objects with two-dimensional codes, and the codes are read by a magnetic scanner, even after being covered with paint or other coatings. The ability to read hidden matrix symbols promises a wide range of benefits in a number of fields, including airlines, electronics, healthcare, and the automotive industry. Many industries would like to hide information on a part, so it can be read only by the party who put it there. For instance, the automotive industry uses direct parts marking for inventory control, but for aesthetic purposes the marks often need to be invisible. Symbols have been applied to a variety of materials, including metal, plastic, glass, paper, fabric and foam, on everything from electronic parts to pharmaceuticals to livestock. The portability of the hand

  6. A new self-made digital slide scanner and microscope for imaging and quantification of fluorescent microspheres

    DEFF Research Database (Denmark)

    Henning, William; Bjerglund Andersen, Julie; Højgaard, Liselotte

    2015-01-01

    Objective: A low-cost microscope slide scanner was constructed for the purpose of digital imaging of newborn piglet brain tissue and to quantify fluorescent microspheres in tissue. Methods: Using a standard digital single-lens reflex (DSLR) camera, fluorescent imaging of newborn piglet brain tissue......-field imaging was tested by adding light diffuser film. Results: Cost of the slide scanner was a fraction of the cost of a commercial slide scanner. The slide scanner was able to image a large number of tissue slides in a semiautomatic manner and provided a large field of view (FOV) of 101 mm2 combined...... and an automatic algorithm to detect fluorescent microspheres in tissue was developed and validated and showed an acceptable difference to “gold standard” manual counting. The slide scanner can be regarded as a low-cost alternative for researchers when digital slide imaging and quantification of fluorescent...

  7. Validity and Repeatability of the Sizestream 3D Scanner and Poikos Modeling System

    NARCIS (Netherlands)

    Vonk, T.E.; Daanen, H.A.M.

    2015-01-01

    Three-dimensional (3D) body scanning becomes increasingly important in the medical, ergonomical and apparel industry. The SizeStream 3D body scanner is a 3D body scanner in the shape of a fitting room that can generate a 3D copy of the human body in a few seconds. The Poikos modeling system

  8. Multispectral optical tweezers for molecular diagnostics of single biological cells

    Science.gov (United States)

    Butler, Corey; Fardad, Shima; Sincore, Alex; Vangheluwe, Marie; Baudelet, Matthieu; Richardson, Martin

    2012-03-01

    Optical trapping of single biological cells has become an established technique for controlling and studying fundamental behavior of single cells with their environment without having "many-body" interference. The development of such an instrument for optical diagnostics (including Raman and fluorescence for molecular diagnostics) via laser spectroscopy with either the "trapping" beam or secondary beams is still in progress. This paper shows the development of modular multi-spectral imaging optical tweezers combining Raman and Fluorescence diagnostics of biological cells.

  9. [A cloud detection algorithm for MODIS images combining Kmeans clustering and multi-spectral threshold method].

    Science.gov (United States)

    Wang, Wei; Song, Wei-Guo; Liu, Shi-Xing; Zhang, Yong-Ming; Zheng, Hong-Yang; Tian, Wei

    2011-04-01

    An improved method for detecting cloud combining Kmeans clustering and the multi-spectral threshold approach is described. On the basis of landmark spectrum analysis, MODIS data is categorized into two major types initially by Kmeans method. The first class includes clouds, smoke and snow, and the second class includes vegetation, water and land. Then a multi-spectral threshold detection is applied to eliminate interference such as smoke and snow for the first class. The method is tested with MODIS data at different time under different underlying surface conditions. By visual method to test the performance of the algorithm, it was found that the algorithm can effectively detect smaller area of cloud pixels and exclude the interference of underlying surface, which provides a good foundation for the next fire detection approach.

  10. A laser scanner for imaging fluorophore labeled molecules in electrophoretic gels

    Energy Technology Data Exchange (ETDEWEB)

    Fisk, D.J.; Sutherland, J.C. [Brookhaven National Lab., Upton, NY (United States). Biology Dept.

    1995-08-01

    A laser scanner for imaging electrophoretic gels was constructed and tested. The scanner incorporates a green helium-neon (HeNe) laser (543.5nm wavelength) and can achieve a spatial resolution of 19{micro}m. The instrument can function in two modes : snap-shot and finish-line. In snapshot mode, all samples are electrophoresed for the same time and the gel is scanned after completion of electrophoresis, while in finish-line mode, fluorophore labeled samples are electrophoresed for a constant distance and the image is formed as the samples pass under the detector. The resolving power of the finish-line mode of imaging is found to be greater than that of the snapshot mode of imaging. This laser scanner is also compared with a Charge Coupled Device (CCD) camera and in terms of resolving power is found to be superior. Sensitivity of the instrument is presented in terms of the minimum amount of DNA that can be detected verses its molecular length.

  11. A passive gamma scanner for estimation of plutonium in fabrication waste

    International Nuclear Information System (INIS)

    Venkatesan, P.P.; Burte, P.P.; Manohar, S.B.; Satya Prakash; Ramaniah, M.V.

    1978-01-01

    The solid plutonium wastes arising from plutonium handling laboratories and fuel fabrication facilities by their very nature (heterogeneous) are not amenable to proper sampling and hence to the standard techniques of estimation. For the proper accounting of nuclear materials a non-destructive method of waste assay is essential. A passive gamma-ray scanner developed in the Radiochemistry Division is described in the present report. The scanner detects the 384 KeV gamma complex of plutonium in a (3'' x 3'') NaI(Tl) detector. The rotation-collimation technique is used to achieve the flat response with respect to the plutonium distribution inside the waste can. The sensitivity of the scanner is 200 mg of Pu per can at 2 sigma level and 20% accuracy for a total scan time of 2000 sec. The assay results of typical waste cans and comparison of a few of these with chemical assay results are presented. This non-destructive method is fast, simple and has satisfactory accuracy. (author)

  12. Multispectral Image Analysis for Robust Prediction of Astaxanthin Coating

    DEFF Research Database (Denmark)

    Ljungqvist, Martin Georg; Frosch, Stina; Nielsen, Michael Engelbrecht

    2013-01-01

    The aim of this study was to investigate the possibility of predicting the type and concentration level of astaxanthin coating of aquaculture feed pellets using multispectral image analysis. We used both natural and synthetic astaxanthin, and we used several different concentration levels...... of synthetic astaxanthin in combination with four different recipes of feed pellets. We used a VideometerLab with 20 spectral bands in the range of 385-1050 nm. We used linear discriminant analysis and sparse linear discriminant analysis for classification and variable selection. We used partial least squares...

  13. Multispectral atmospheric mapping sensor of mesoscale water vapor features

    Science.gov (United States)

    Menzel, P.; Jedlovec, G.; Wilson, G.; Atkinson, R.; Smith, W.

    1985-01-01

    The Multispectral atmospheric mapping sensor was checked out for specified spectral response and detector noise performance in the eight visible and three infrared (6.7, 11.2, 12.7 micron) spectral bands. A calibration algorithm was implemented for the infrared detectors. Engineering checkout flights on board the ER-2 produced imagery at 50 m resolution in which water vapor features in the 6.7 micron spectral band are most striking. These images were analyzed on the Man computer Interactive Data Access System (McIDAS). Ground truth and ancillary data was accessed to verify the calibration.

  14. Method using in vivo quantitative spectroscopy to guide design and optimization of low-cost, compact clinical imaging devices: emulation and evaluation of multispectral imaging systems

    Science.gov (United States)

    Saager, Rolf B.; Baldado, Melissa L.; Rowland, Rebecca A.; Kelly, Kristen M.; Durkin, Anthony J.

    2018-04-01

    With recent proliferation in compact and/or low-cost clinical multispectral imaging approaches and commercially available components, questions remain whether they adequately capture the requisite spectral content of their applications. We present a method to emulate the spectral range and resolution of a variety of multispectral imagers, based on in-vivo data acquired from spatial frequency domain spectroscopy (SFDS). This approach simulates spectral responses over 400 to 1100 nm. Comparing emulated data with full SFDS spectra of in-vivo tissue affords the opportunity to evaluate whether the sparse spectral content of these imagers can (1) account for all sources of optical contrast present (completeness) and (2) robustly separate and quantify sources of optical contrast (crosstalk). We validate the approach over a range of tissue-simulating phantoms, comparing the SFDS-based emulated spectra against measurements from an independently characterized multispectral imager. Emulated results match the imager across all phantoms (<3 % absorption, <1 % reduced scattering). In-vivo test cases (burn wounds and photoaging) illustrate how SFDS can be used to evaluate different multispectral imagers. This approach provides an in-vivo measurement method to evaluate the performance of multispectral imagers specific to their targeted clinical applications and can assist in the design and optimization of new spectral imaging devices.

  15. Coastal Zone Color Scanner studies

    Science.gov (United States)

    Elrod, J.

    1988-01-01

    Activities over the past year have included cooperative work with a summer faculty fellow using the Coastal Zone Color Scanner (CZCS) imagery to study the effects of gradients in trophic resources on coral reefs in the Caribbean. Other research included characterization of ocean radiances specific to an acid-waste plume. Other activities include involvement in the quality control of imagery produced in the processing of the global CZCS data set, the collection of various other data global sets, and the subsequent data comparison and analysis.

  16. Beam hardening artifacts by dental implants: Comparison of cone-beam and 64-slice computed tomography scanners

    Directory of Open Access Journals (Sweden)

    Farzad Esmaeili

    2013-01-01

    Full Text Available Background: Cone beam computed tomography (CBCT is an alternative to a computed tomography (CT scan, which is appropriate for a wide range of craniomaxillofacial indications. The long-term use of metallic materials in dentistry means that artifacts caused by metallic restorations in the oral cavity should be taken into account when utilizing CBCT and CT scanners. The aim of this study was to quantitatively compare the beam hardening artifacts produced by dental implants between CBCT and a 64-Slice CT scanner. Materials and Methods: In this descriptive study , an implant drilling model similar to the human mandible was used in the present study. The implants (Dentis were placed in the canine, premolar and molar areas. Three series of scans were provided from the implant areas using Somatom Sensation 64-slice and NewTom VGi (CBCT CT scanners. Identical images were evaluated by three radiologists. The artifacts in each image were determined based on pre-determined criteria. Kruskal-Wallis test was used to compare mean values; Mann-Whitney U test was used for two-by-two comparisons when there was a statistical significance ( P < 0.05. Results: The images of the two scanners had similar resolutions in axial sections ( P = 0.299. In coronal sections, there were significant differences in the resolutions of the images produced by the two scanners ( P < 0.001, with a higher resolution in the images produced by NewTom VGi scanner. On the whole, there were significant differences between the resolutions of the images produced by the two CT scanners ( P < 0.001, with higher resolution in the images produced by NewTom VGi scanner in comparison to those of Somatom Sensation. Conclusion: Given the high quality of the images produced by NewTom VGi and the lower costs in comparison to CT, the use of the images of this scanner in dental procedures is recommended, especially in patients with extensive restorations, multiple prostheses and previous implants.

  17. Two-Dimensional Metrology with Flatbed Scanners at Room and Liquid Nitrogen Temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Grau Carles, A.; Grau Malonda, A. [CIEMAT. Madrid (Spain)

    2000-07-01

    We study the capability of the commercial flatbed scanner as a measuring instrument of two-coordinate sample both at room and liquid nitrogen temperatures. We describes simple procedure to calibrate the scanner, and the most adequate standard configuration to carry out the measurements. To illustrate the procedure, we measure the relative positions of the conductors in a cross-section of a superconducting magnet of CERN. (Author) 8 refs.

  18. Two-Dimensional Metrology with Flatbed Scanners at Room and Liquid Nitrogen Temperatures

    International Nuclear Information System (INIS)

    Grau Carles, A.; Grau Malonda, A.

    2000-01-01

    We study the capability of the commercial flatbed scanner as a measuring instrument of two-coordinate sample both at room and liquid nitrogen temperatures. We describes simple procedure to calibrate the scanner, and the most adequate standard configuration to carry out the measurements. To illustrate the procedure, we measure the relative positions of the conductors in a cross-section of a superconducting magnet of CERN. (Author) 8 refs

  19. A Multispectral Micro-Imager for Lunar Field Geology

    Science.gov (United States)

    Nunez, Jorge; Farmer, Jack; Sellar, Glenn; Allen, Carlton

    2009-01-01

    Field geologists routinely assign rocks to one of three basic petrogenetic categories (igneous, sedimentary or metamorphic) based on microtextural and mineralogical information acquired with a simple magnifying lens. Indeed, such observations often comprise the core of interpretations of geological processes and history. The Multispectral Microscopic Imager (MMI) uses multi-wavelength, light-emitting diodes (LEDs) and a substrate-removed InGaAs focal-plane array to create multispectral, microscale reflectance images of geological samples (FOV 32 X 40 mm). Each pixel (62.5 microns) of an image is comprised of 21 spectral bands that extend from 470 to 1750 nm, enabling the discrimination of a wide variety of rock-forming minerals, especially Fe-bearing phases. MMI images provide crucial context information for in situ robotic analyses using other onboard analytical instruments (e.g. XRD), or for the selection of return samples for analysis in terrestrial labs. To further assess the value of the MMI as a tool for lunar exploration, we used a field-portable, tripod-mounted version of the MMI to image a variety of Apollo samples housed at the Lunar Experiment Laboratory, NASA s Johnson Space Center. MMI images faithfully resolved the microtextural features of samples, while the application of ENVI-based spectral end member mapping methods revealed the distribution of Fe-bearing mineral phases (olivine, pyroxene and magnetite), along with plagioclase feldspars within samples. Samples included a broad range of lithologies and grain sizes. Our MMI-based petrogenetic interpretations compared favorably with thin section-based descriptions published in the Lunar Sample Compendium, revealing the value of MMI images for astronaut and rover-mediated lunar exploration.

  20. Feature-space transformation improves supervised segmentation across scanners

    DEFF Research Database (Denmark)

    van Opbroek, Annegreet; Achterberg, Hakim C.; de Bruijne, Marleen

    2015-01-01

    Image-segmentation techniques based on supervised classification generally perform well on the condition that training and test samples have the same feature distribution. However, if training and test images are acquired with different scanners or scanning parameters, their feature distributions...