WorldWideScience

Sample records for air study 1999-2001

  1. KUALITAS FISIK DAN KIMIA AIR PAM DI JAKARTA, BOGOR, TANGERANG, BEKASI TAHUN 1999 - 2001

    Directory of Open Access Journals (Sweden)

    Mariana Raini

    2012-09-01

    Full Text Available Drinking water quality of PAM in Jakarta, Bogor, Tangerang and Bekasi between the year of 1999 - 2001 has been studied. Water quality was determined by a series of physical and chemical test at Chemical Laboratory Pusat Penelitian dan Pengembangan Farmasi dan Obat Tradisional as stated in Permenkes no.416/Menkes/Per/IX/1990 on condition and water quality control including smell, color, turbidity, contents of manganese, iron, nitrite, sulphate, organic subtance, turbidity, hardness and pH. Total sampling was done on all drinking water samples from DKI Jakarta, Bogor, Tangerang and Bekasi delivered to be tested at Pusat Penelitian dan Pengembangan Farmasi dan Obat Tradisional between 1999-2001 and destilled water as control. Result of the study from 431 drinking water samples shows that samples that met the requirements as drinking water is 91,65% and 8,35% sub standard, most of the the sub standard drinking water is cause by the contents of manganese (4,41%, iron (2,09%, organic subtance (1,62%, chloride (0,93% and high water hardness (0,23% as well as pH (3,15%, turbidity (1,86% and colors (1,62% Statistically, the water quality of PAM in Jakarta, Bogor, Tangerang and Bekasi at 1999, 2000 and 2001 is not different.  Key word : water quality of PAM, drinking water, physical test, chemical test.

  2. Patterns of pretreatment diagnostic assessment and staging for patients with cervical cancer (1999-2001). Patterns of care study in Japan

    International Nuclear Information System (INIS)

    Toita, Takafumi; Kodaira, Takeshi; Uno, Takashi; Shinoda, Atsunori; Akino, Yuichi; Teshima, Teruki; Mitsumori, Michihide

    2008-01-01

    The objective of this study was to evaluate the patterns of pretreatment diagnostic assessment in uterine cervical cancer patients treated with definitive radiotherapy in Japan. The Japanese Patterns of Care Study working group conducted a second extramural audit survey of 68 institutions and collected specific information on 631 patients with cervical cancer. All patients were treated with radiotherapy in 1999-2001. Of these, 324 patients treated without surgery were the subjects of this study. International Federation of Gynecology and Obstetrics-prescribed diagnostic procedures were performed at moderate rates in our study cohort. The performance rates of chest X-ray, intravenous urography, cystoscopy, and proctoscopy were 74, 54, 53, and 33%, respectively. Cross sectional imaging studies were frequently performed. Pelvic CT, abdominal CT, and pelvic MRI were performed in 88, 80, and 76%, respectively. Lymphangiography (1%) and surgical evaluation (1%) were rarely done. Only one patient underwent positron emission tomography (PET) scans in this survey period. This study demonstrated the patterns of pretreatment diagnostic assessment in cervical cancer patients treated with definitive radiotherapy in Japan. (author)

  3. Patterns of Radiotherapy Practice for Patients With Cervical Cancer (1999-2001): Patterns of Care Study in Japan

    International Nuclear Information System (INIS)

    Toita, Takafumi; Kodaira, Takeshi; Shinoda, Atsunori; Uno, Takashi; Akino, Yuichi; Mitsumori, Michihide; Teshima, Teruki

    2008-01-01

    Purpose: To describe the patterns of definitive radiotherapy practice for patients with uterine cervical cancer from 1999 to 2001 in Japan. Methods and Materials: The Japanese Patterns of Care Study (JPCS) working group conducted a third extramural audit survey of 68 institutions and collected specific information on 324 cervical cancer patients treated with definitive radiotherapy. Results: Almost all patients (96%) were treated with whole pelvic radiotherapy using opposing anteroposterior fields (87%). A midline block was used in 70% of the patients. Intracavitary brachytherapy (ICBT) was applied in 82% of cases. Most patients (89%) were treated with high-dose rate (HDR) ICBT. Calculation of doses to organs at risk (ICRU 38) was performed for rectum in 25% of cases and for bladder in 18% of cases. Only 3% of patients were given intravenous conscious sedation during ICBT applicator insertions. The median total biologically effective dose at point A (EBRT+ICBT) was 74 Gy 10 in cases treated with HDR-ICBT. There was no significant difference in total biologically effective dose between stages. The median overall treatment time was 47 days. Concurrent chemoradiation was applied in 17% of patients. Conclusions: This study describes the general patterns of radiotherapy practice for uterine cervical cancer in Japan. Although methods of external radiotherapy seemed to be appropriate, there was room for improvement in ICBT practice, such as pretreatment. A substantial difference in total radiotherapy dose between Japan and the United States was observed

  4. Suicide risk in relation to social class: a national register-based study of adult suicides in Korea, 1999-2001.

    Science.gov (United States)

    Kim, Moon-Doo; Hong, Seong-Chul; Lee, Sang-Yi; Kwak, Young-Sook; Lee, Chang-In; Hwang, Seung-Wook; Shin, Tae-Kyun; Lee, Seung-Min; Shin, Ji-Nam

    2006-03-01

    Few controlled studies have examined social class as a risk factor for suicide in Korea. The objective of the present study was to investigate the effects of social class on suicide risk in Korea. A case-control design was constructed from cause-of-death statistics for the period 1999 to 2001, in Korea, as published by the Korean National Statistical Office. The cases were defined as people aged between 20 and 64 who died by suicide, while the controls were defined as those who died of natural causes in the same age groups. The proportions and odds ratios for suicide were higher in young people than in elderly people, and higher for divorced subjects than for cohabitants. They were also higher for residents of rural areas, as opposed to residents of Seoul and other metropolitan areas, and for people in social classes III and IV, than they were for those in social class I. To control the variables that influence risk of suicide, such as age, marital status and area of residence, we used multiple logistic regression. Compared with class I, risk of suicide was higher in social classes III and IV, in both sexes. The principal conclusion of this study is that, regardless of sex, lower social class constitutes a high risk for suicide in Korea, even after controlling for variables such as age, marital status and area of residence. We conclude that a well-controlled and balanced social welfare system could reduce suicide risk, especially among people in lower social class.

  5. Association Between History of Multiple Concussions and Health Outcomes Among Former College Football Players: 15-Year Follow-up From the NCAA Concussion Study (1999-2001).

    Science.gov (United States)

    Kerr, Zachary Y; Thomas, Leah C; Simon, Janet E; McCrea, Michael; Guskiewicz, Kevin M

    2018-06-01

    Previous research has examined associations between concussion history and adverse health outcomes among former professional football players. Less is known about the potential effects of concussion among former college football players without additional exposure at the professional level. To examine the association between concussion and adverse health outcomes in a cohort of former college football players without exposure to professional football, 15 years after their playing careers ended. Cross-sectional study; Level of evidence, 3. A sample of 204 former collegiate football players (23.4% of eligible athletes with available contact information)-all of whom played at least 1 season of football from 1999 to 2001 in the National Collegiate Athletic Association (NCAA) and had no professional football exposure-completed a general health survey that assessed lifetime concussion history and included the following: the Veterans RAND 36 Item Health Survey, containing a physical composite score (PCS) and mental composite score (MCS); the depression module of the Patient Health Questionnaire; and the 4-item CAGE alcohol dependence questionnaire (for "cutting down, annoyance by criticism, guilty feeling, and eye-openers"). Multivariable binomial regression models estimated adjusted prevalence ratios (PRs) with 95% CIs while controlling for demographics and playing history covariates through forward selection model building. Most participants reported a concussion history (84.3%). Overall, 22.1% and 39.2% of participants reported a PCS and an MCS history of multiple concussions and adverse health outcomes were found among former collegiate football players without professional football exposure but were limited to those reporting ≥3 prior concussions. Because only 23.4% of eligible athletes responded to the survey, the possibility of ascertainment bias exists, and our findings should thus be interpreted with some caution. Continued examination within nonprofessional

  6. Epidemiology of multiple Acinetobacter outbreaks in The Netherlands during the period 1999-2001

    NARCIS (Netherlands)

    van den Broek, P. J.; Arends, J.; Bernards, A. T.; De Brauwer, E.; Mascini, E. M.; van der Reijden, T. J. K.; Spanjaard, L.; Thewessen, E. A. P. M.; van der Zee, A.; van Zeijl, J. H.; Dijkshoorn, L.

    An increase in the number of outbreaks of Acinetobacter infection was notified in The Netherlands during 1999-2001. The present study compared the outbreaks at the species and strain levels, and analysed the epidemiology and control measures at the different locations. For each institute, three

  7. Pelagic Charter Boat Patrons (1999-2001)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This study describes several aspects of the charter fishing experience, including patrons' motivations for coming to Hawaii and going charter fishing, their related...

  8. Hawaii Coral Reef Assessment and Monitoring Program (CRAMP): benthic data from 1999 - 2001 (NODC Accession 0000969)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This dataset consists of CRAMP surveys taken in 1999-2001 and includes quantitative estimates of substrate type, species type, and percent coverage. Fish data are...

  9. Epidemiologia delle batteriemie nosocomiali in Lombardia nel triennio 1999-2001

    Directory of Open Access Journals (Sweden)

    Egidio Franco Viganò

    2004-12-01

    Full Text Available We analyzed bloodstream infection(BI performed in eight hospitals in Region Lombardia in the period 1999- 2001 following criteria and methods as in the study performed in the year 1997.Data were evaluated from 434.000 hospital patients (one third of hospital patients annualy recovered in Lombardia Region each year. Of these 56.3 positive blood coltures /1000 patients were observed. Data were similar as 1997. In total 3063 episodes of bacteriemia were observed (6.98 BI / 1000 hospital patients.53% of cases correlated to hospital infection. Organism identification of causative organisms resulted 22.5% for E.coli and 10.6% for KES; 17.7% S.aureus,4.5% Yeast .Anaerobic bacteria resulted involved in 3.4%.Among the frequency of isolates difference was noted in different wards In intensive care unit E.coli was pathogenic in 5.9% of patients, but KES in 25.5% of cases. Differences were noted if nosocomial or comunity infections were involved. It was concluded that epidemiological data of BI from all the hospital of Region Lombardia could support the knowledge of bacteriemic episodes in different wards as useful method of surveillance particularly in order to control economic aspects and efficacy of prevention.

  10. Monitoring of radionuclides in the vicinities of Finnish nuclear power plants in 1999-2001

    International Nuclear Information System (INIS)

    Ikaeheimonen, T.K.; Klemola, S.; Illus, E.; Vartti, V.P.; Mattila, J.

    2006-09-01

    Monitoring of the radioactive substances around Finnish nuclear power plants continued in 1999-2001 in accordance with the regular environmental monitoring programmes. Altogether some 1000 samples are analysed annually from the terrestrial and aquatic environs of the two power plants. Trace amounts of activation products originating from airborne releases from the local power plants were detected in several air and deposition samples. At Loviisa, observations were made in five aerosol samples; at Olkiluoto in three samples during the reporting period. The concentrations were very low, being a few microbequerels per cubic metre. A similar pattern was tenable for the deposition samples, too. No traces of local discharge nuclides were detected in foodstuffs, drinking water or garden products. In mushrooms and wild berries picked from the Loviisa and Olkiluoto areas, only Chernobyl-derived cesium isotopes and natural 40 K were found. Local discharge nuclides were more abundant in the aquatic environment, especially in samples of indicator organisms, sinking matter and sediments. The dominant artificial radionuclides in the vicinity of the power plants were still the caesium isotopes, especially 137 Cs, originating from the Chernobyl accident. In seawater, elevated 3 H concentrations were more frequent at Loviisa, but no traces of other discharge nuclides were detected. In indicator organisms and sinking matter the concentrations of local discharge nuclides were somewhat higher and their distribution range was wider in the sea area off Olkiluoto. Small amounts of 60 Co originating from the local power plant were detected in sediments at a distance of about 15 km from the Olkiluoto NPP. (orig.)

  11. Comparison of Toxoplasma gondii Seroprevalence in Shelter Cats and Dogs during 1999-2001 and 2009-2011 in Tokyo, Japan.

    Science.gov (United States)

    Oi, Masaaki; Yoshikawa, Souichi; Maruyama, Soichi; Nogami, Sadao

    2015-01-01

    Toxoplasma gondii is an important human health concern with respect to abortion, congenital hydrocephalus, and encephalitis in immunocompromised people. Cats and dogs both are potential sources of T. gondii because they have close contact with humans. However, no epidemiological surveys have been conducted in Tokyo over the past decade. Therefore, the present study investigated and compared the seroprevalence of T. gondii infection in shelter cats and dogs during 1999-2001 and 2009-2011 in Tokyo, Japan. Serum samples were collected from 337 shelter cats and 325 shelter dogs in urban and suburban areas of Tokyo, during 1999-2001 (233 cats and 219 dogs) and 2009-2011 (104 cats and 106 dogs). T. gondii antibodies were measured in the serum samples using a commercial latex agglutination test. Data were compared using the Fisher's exact test, and significance was indicated at P cats was 5.6% (13 of 233) in 1999-2001 and 6.7% (7 of 104) in 2009-2011, and that in dogs was 1.8% (4 of 219) and 1.9% (2 of 106), respectively. Significantly higher seroprevalence was observed in cats from suburban areas compared with cats in urban areas during both periods (P cats and dogs in Tokyo is considerably low as the seroprevalence has reached a steady state.

  12. Comparison of Toxoplasma gondii Seroprevalence in Shelter Cats and Dogs during 1999-2001 and 2009-2011 in Tokyo, Japan.

    Directory of Open Access Journals (Sweden)

    Masaaki Oi

    Full Text Available Toxoplasma gondii is an important human health concern with respect to abortion, congenital hydrocephalus, and encephalitis in immunocompromised people. Cats and dogs both are potential sources of T. gondii because they have close contact with humans. However, no epidemiological surveys have been conducted in Tokyo over the past decade. Therefore, the present study investigated and compared the seroprevalence of T. gondii infection in shelter cats and dogs during 1999-2001 and 2009-2011 in Tokyo, Japan. Serum samples were collected from 337 shelter cats and 325 shelter dogs in urban and suburban areas of Tokyo, during 1999-2001 (233 cats and 219 dogs and 2009-2011 (104 cats and 106 dogs. T. gondii antibodies were measured in the serum samples using a commercial latex agglutination test. Data were compared using the Fisher's exact test, and significance was indicated at P < 0.05. The overall seroprevalence of T. gondii infection in cats was 5.6% (13 of 233 in 1999-2001 and 6.7% (7 of 104 in 2009-2011, and that in dogs was 1.8% (4 of 219 and 1.9% (2 of 106, respectively. Significantly higher seroprevalence was observed in cats from suburban areas compared with cats in urban areas during both periods (P < 0.05. These results reveal that there has been little change in the feline and canine seroprevalence over the past decade, indicating that the risk of T. gondii exposure for cats and dogs in Tokyo is considerably low as the seroprevalence has reached a steady state.

  13. Possible seismogenic origin of changes in the ULF EM resonant structure observed at Teoloyucan geomagnetic station, Mexico, 1999-2001

    Directory of Open Access Journals (Sweden)

    A. Kotsarenko

    2005-01-01

    Full Text Available The evolution of the ULF resonant structure observed at Teoloyucan geomagnetic station has been provisionally studied in a possible relation with seismic activity in Mexico in the period 1999-2001. Two resonant lines were observed in the H-component (linear polarization in the frequency bands fR2=10.2–11.1 mHz and fR2=13.6–14.5 mHz, sometimes accompanied by other harmonics. The source of the observed resonances is possibly related with the geomagnetic location of the station (geomagnetic latitude λ=29.1° and its proximity to the equatorial electrojet (λ~30°. An enhancement of the carrier frequency of both resonances in the period 1 month–2 weeks was found before the strongest EQs. Also, a depression of the resonant structure just a few days before and a few days after some EQs seems to be correlated with seismic activity.

  14. Transports and tidal current estimates in the Taiwan Strait from shipboard ADCP observations (1999-2001)

    Science.gov (United States)

    Wang, Y. H.; Jan, S.; Wang, D. P.

    2003-05-01

    Tidal and mean flows in the Taiwan Strait are obtained from analysis of 2.5 years (1999-2001) of shipboard ADCP data using a spatial least-squares technique. The average tidal current amplitude is 0.46 ms -1, the maximum amplitude is 0.80 ms -1 at the northeast and southeast entrances and the minimum amplitude is 0.20 ms -1 in the middle of the Strait. The tidal current ellipses derived from the shipboard ADCP data compare well with the predictions of a high-resolution regional tidal model. For the mean currents, the average velocity is about 0.40 ms -1. The mean transport through the Strait is northward (into the East China Sea) at 1.8 Sv. The transport is related to the along Strait wind by a simple regression, transport (Sv)=2.42+0.12×wind (ms -1). Using this empirical formula, the maximum seasonal transport is in summer, about 2.7 Sv, the minimum transport is in winter, at 0.9 Sv, and the mean transport is 1.8 Sv. For comparison, this result indicates that the seasonal amplitude is almost identical to the classical estimate by Wyrtki (Physical oceanography of the southeast Asian waters, scientific results of marine investigations of the South China Sea and Gulf of Thailand, 1959-1961. Naga Report 2, Scripps Institute of Oceanography, 195 pp.) based on the mass balance in the South China Sea, while the mean is close to the recent estimate by Isobe [Continental Shelf Research 19 (1999) 195] based on the mass balance in the East China Sea.

  15. Rakendusuuringute ja analüüside tellimine valitsusasutustes 1999-2001 : teel teadmistepõhisema poliitika, õigusloome ja avaliku halduse poole / Aare Kasemets

    Index Scriptorium Estoniae

    Kasemets, Aare, 1963-

    2002-01-01

    Ülevaade Riigikogu Toimetiste poolt korraldatud parlamendiuuringust ja selle eesmärkidest, valitsusasutustes aastail 1999-2001 tellitud uuringute arvust ja kuludest ning võimalikest lahendusideedest uuringute tellimise korraldusega seonduvatele probleemidele. Tabelid

  16. Self-reported health as a cultural health determinant in Arab and Jewish Israelis MABAT--National Health and Nutrition Survey 1999-2001.

    Science.gov (United States)

    Baron-Epel, Orna; Kaplan, Giora; Haviv-Messika, Amalia; Tarabeia, Jalal; Green, Manfred S; Kaluski, Dorit Nitzan

    2005-09-01

    Subjective health (SH) status serves as a measure of health in many studies of health-related issues as it is a good predictor of mortality, morbidity, and use of health services. The measure is used in many population groups. However, the degree to which it measures the same condition in different ethnic groups is not clear. Within Israel's first National Health and Nutrition Survey (MABAT) conducted during 1999-2001, face-to-face interviews were held with 3222 Israeli interviewees, 2379 Jews and 843 Arabs, aged between 25-64 years. Respondents reported their SH, co-morbidity, and other socioeconomic characteristics. Arabs reported higher levels of SH than Jews. In logistic regression analysis, co-morbidity was a much stronger correlate of poorer SH in the Arab than in the Jewish population. The association between socioeconomic variables depended on ethnic group and sex. The findings indicate that SH in Jews and Arabs does not necessarily have the same meaning in relation to objective measures of health, and caution should be exercised in the use of this measure in different population groups with different cultures. Arabs tend to evaluate health better than Jews even though life expectancy is lower and morbidity and mortality are higher in the former population group. Yet diagnosis of a disease increases the frequency of reporting lower SH, more in Arabs than in Jews.

  17. Changing patterns of spatial clustering of schistosomiasis in Southwest China between 1999-2001 and 2007-2008: assessing progress toward eradication after the World Bank Loan Project.

    Science.gov (United States)

    Hu, Yi; Xiong, Chenglong; Zhang, Zhijie; Luo, Can; Cohen, Ted; Gao, Jie; Zhang, Lijuan; Jiang, Qingwu

    2014-01-03

    We compared changes in the spatial clustering of schistosomiasis in Southwest China at the conclusion of and six years following the end of the World Bank Loan Project (WBLP), the control strategy of which was focused on the large-scale use of chemotherapy. Parasitological data were obtained through standardized surveys conducted in 1999-2001 and again in 2007-2008. Two alternate spatial cluster methods were used to identify spatial clusters of cases: Anselin's Local Moran's I test and Kulldorff's spatial scan statistic. Substantial reductions in the burden of schistosomiasis were found after the end of the WBLP, but the spatial extent of schistosomiasis was not reduced across the study area. Spatial clusters continued to occur in three regions: Chengdu Plain, Yangtze River Valley, and Lancang River Valley during the two periods, and regularly involved five counties. These findings suggest that despite impressive reductions in burden, the hilly and mountainous regions of Southwest China remain at risk of schistosome re-emergence. Our results help to highlight specific locations where integrated control programs can focus to speed the elimination of schistosomiasis in China.

  18. REVIEW OF THE NATIONAL RESTOCKING PROGRAMME “ACTIVE PROTECTION OF NATIVE CRAYFISH IN POLAND” 1999-2001

    Directory of Open Access Journals (Sweden)

    ŠMIETANA P.

    2004-01-01

    Full Text Available After the first spread of crayfish plague (aphanomycosis at the end of the nineteenth century, the formerly abundant populations of native crayfish in Poland declined drastically. Analysis of historical data on the occurrence and distribution of crayfish in Poland led to the conclusion that without human intervention the native crayfish species would be at high risk of being made extinct. The largest programme concerning crayfish monitoring and restocking in Poland was “Active protection of native crayfish in Poland” conducted by the Inland Fisheries Institute, the Department of Ecology, University of Szczecin, the Department of Zoology, Warsaw Agricultural University and the University of Warmia and Mazury that was funded by the EkoFundusz Foundation and Inland Fisheries Institute in 1999-2001. One of the main objectives and results of this programme was the determination of indigenous crayfish distribution in Poland (mainly Astacus astacus and Astacus leptodactylus and the restocking of suitable habitats with indigenous crayfish. The densest populations (> 2 500 adult individuals per hectare were used as a source of restocking material. Restocking was performed in 54 water bodies using a total of 45 200 individuals of A. astacus and 9 800 of A. leptodactylus. Between 2001-2002, the success of the restocking programme was monitored. According to the results obtained so far, the restocking exercise has been successful in at least 60.8% of the cases.

  19. LBA-ECO ND-04 Termite Mound and Soil Characterization, Amazonas, Brazil: 1999-2001

    Data.gov (United States)

    National Aeronautics and Space Administration — ABSTRACT: This data set reports the results of a comprehensive study of mound building termites at the Embrapa research station in the Distrito Agropecuario da...

  20. LBA-ECO ND-04 Termite Mound and Soil Characterization, Amazonas, Brazil: 1999-2001

    Data.gov (United States)

    National Aeronautics and Space Administration — This data set reports the results of a comprehensive study of mound building termites at the Embrapa research station in the Distrito Agropecuario da SUFRAMA,...

  1. Access block in NSW hospitals, 1999-2001: does the definition matter?

    Science.gov (United States)

    Forero, Roberto; Mohsin, Mohammed; Bauman, Adrian E; Ieraci, Sue; Young, Lis; Phung, Hai N; Hillman, Kenneth M; McCarthy, Sally M; Hugelmeyer, C David

    2004-01-19

    To estimate the magnitude of access block and its trend over time in New South Wales hospitals, using different definitions of access block, and to explore its association with clinical and non-clinical factors. An epidemiological study using the Emergency Department Information System datasets (1 January 1999 to 31 December 2001) from a sample of 55 NSW hospitals. Prevalence of access block measured by four different definitions; strength of association between access block, type of hospital, year of presentation, mode and time of arrival, triage category (an indicator of urgency), age and sex. Rates of access block (for all four definitions) increased between 1999 and 2001 by 1%-2% per year. There were increases across all regions of NSW, but urban regions in particular. Patients presenting to Principal Referral hospitals and those who arrived at night were more likely to experience access block. After adjusting for triage category and year of presentation, the mode of arrival, time of arrival, type of hospital, age and sex were significantly associated with access block. Access block continues to increase across NSW, whatever the definition used. We recommend that hospitals in NSW and Australia move to the use of one standard definition of access block, as our study suggests there is no significant additional information emerging from the use of multiple definitions.

  2. An update of hydrologic conditions and distribution of selected constituents in water, Snake River Plain aquifer, Idaho National Laboratory, Idaho, Emphasis 1999-2001

    Science.gov (United States)

    Davis, Linda C.

    2006-01-01

    Radiochemical and chemical wastewater discharged since 1952 to infiltration ponds, evaporation ponds, and disposal wells at the Idaho National Laboratory (INL) has affected water quality in the Snake River Plain aquifer underlying the INL. The U.S. Geological Survey (USGS), in cooperation with the U.S. Department of Energy, maintains ground-water monitoring networks at the INL to determine hydrologic trends, and to delineate the movement of radiochemical and chemical wastes in the aquifer. This report presents an analysis of water-level and water-quality data collected from wells in the USGS ground-water monitoring networks during 1999-2001. Water in the Snake River Plain aquifer moves principally through fractures and interflow zones in basalt, generally flows southwestward, and eventually discharges at springs along the Snake River. The aquifer is recharged principally from infiltration of irrigation water, infiltration of streamflow, ground-water inflow from adjoining mountain drainage basins, and infiltration of precipitation. Water levels in wells rose in the northern and west-central parts of the INL by 1 to 3 feet, and declined in the southwestern parts of the INL by up to 4 feet during 1999-2001. Detectable concentrations of radiochemical constituents in water samples from wells in the Snake River Plain aquifer at the INL generally decreased or remained constant during 1999-2001. Decreases in concentrations were attributed to decreased rates of radioactive-waste disposal, radioactive decay, changes in waste-disposal methods, and dilution from recharge. Tritium concentrations in water samples decreased as much as 8.3 picocuries per milliliter (pCi/mL) during 1999-2001, ranging from 0.43?0.14 to 13.6?0.6 pCi/mL in October 2001. Tritium concentrations in five wells near the Idaho Nuclear Technology and Engineering Center (INTEC) increased a few picocuries per milliliter from October 2000 to October 2001. Strontium-90 concentrations decreased or remained

  3. Geochemical characterization of water, sediment, and biota affected by mercury contamination and acidic drainage from historical gold mining, Greenhorn Creek, Nevada County, California, 1999-2001

    Science.gov (United States)

    Alpers, Charles N.; Hunerlach, Michael P.; May, Jason T.; Hothem, Roger L.; Taylor, Howard E.; Antweiler, Ronald C.; De Wild, John F.; Lawler, David A.

    2005-01-01

    In 1999, the U.S. Geological Survey (USGS) initiated studies of mercury and methylmercury occurrence, transformation, and transport in the Bear River and Yuba River watersheds of the northwestern Sierra Nevada. Because these watersheds were affected by large-scale, historical gold extraction using mercury amalgamation beginning in the 1850s, they were selected for a pilot study of mercury transport by the USGS and other cooperating agencies. This report presents data on methylmercury (MeHg) and total mercury (THg) concentrations in water, bed sediment, invertebrates, and frogs collected at 40 stations during 1999-2001 in the Greenhorn Creek drainage, a major tributary to Bear River. Results document several mercury contamination ?hot spots? that represent potential targets for ongoing and future remediation efforts at abandoned mine sites in the study area. Water-quality samples were collected one or more times at each of 29 stations. The concentrations of total mercury in 45 unfiltered water samples ranged from 0.80 to 153,000 nanograms per liter (ng/L); the median was 9.6 ng/L. Total mercury concentrations in filtered water (41 samples) ranged from less than 0.3 to 8,000 ng/L; the median was 2.7 ng/L. Concentrations of methylmercury in the unfiltered water (40 samples) ranged from less than 0.04 to 9.1 ng/L; the median was 0.07 ng/L. Methylmercury in filtered water (13 samples) ranged from less than 0.04 to 0.27 ng/L; the median was 0.04 ng/L. Acidic drainage with pH values as low as 3.4 was encountered in some of the mined areas. Elevated concentrations of aluminum, cadmium, copper, iron, manganese, nickel, and zinc were found at several stations, especially in the more acidic water samples. Total mercury concentrations in sediment were determined by laboratory and field methods. Total mercury concentrations (determined by laboratory methods) in ten samples from eight stations ranged from about 0.0044 to 12 ?g/g (microgram per gram, equivalent to parts per

  4. An update of the distribution of selected radiochemical and chemical constituents in perched ground water, Idaho National Laboratory, Idaho, Emphasis 1999-2001

    Science.gov (United States)

    Davis, Linda C.

    2006-01-01

    Radiochemical and chemical wastes generated at facilities at the Idaho National Laboratory (INL) were discharged since 1952 to infiltration ponds at the Reactor Technology Complex (RTC) (known as the Test Reactor Area [TRA] until 2005), and the Idaho Nuclear Technology and Engineering Center (INTEC) and buried at the Radioactive Waste Management Complex (RWMC). Disposal of wastewater to infiltration ponds and infiltration of surface water at waste burial sites resulted in formation of perched ground water in basalts and in sedimentary interbeds above the Snake River Plain aquifer. Perched ground water is an integral part of the pathway for waste-constituent migration to the aquifer. The U.S. Geological Survey (USGS), in cooperation with the U.S. Department of Energy, maintains ground-water monitoring networks at the INL to determine hydrologic trends, and to monitor the movement of radiochemical and chemical constituents in wastewater discharged from facilities to both perched ground water and the aquifer. This report presents an analysis of water-quality and water-level data collected from wells completed in perched ground water at the INL during 1999-2001, and summarizes historical disposal data and water-level-and water-quality trends. At the RTC, tritium, strontium-90, cesium-137, dissolved chromium, chloride, sodium, and sulfate were monitored in shallow and deep perched ground water. In shallow perched ground water, no tritium was detected above the reporting level. In deep perched ground water, tritium concentrations generally decreased or varied randomly during 1999-2001. During October 2001, tritium concentrations ranged from less than the reporting level to 39.4?1.4 picocuries per milliliter (pCi/mL). Reportable concentrations of tritium during July-October 2001 were smaller than the reported concentrations measured during July-December 1998. Tritium concentrations in water from wells at the RTC were likely affected by: well's distance from the

  5. Risøs treårsplan 1999-2001. Rullende 3-årsplan med hovedlinier for året 1999 og perspektiver for årene 2000 og 2001

    DEFF Research Database (Denmark)

    Forskningscenter Risø, Roskilde

    1999-01-01

    Denne treårsplan fastlægger rammerne for Forskningscenter Risøs virksomhed i perioden 1999-2001. Risø hører under Forskningsministeriet og driver naturvidenskabelig og teknisk-videnskabelig forskning med det formål at skabe nye udviklingsmuligheder forerhvervsliv og samfund rettet mod anvendelse ...

  6. Algumas repercussões emocionais negativas da gravidez precoce em adolescentes do Município do Rio de Janeiro (1999-2001 Some emotional repercussions of adolescent pregnancy in Rio de Janeiro, Brazil (1999-2001

    Directory of Open Access Journals (Sweden)

    Adriane Reis Sabroza

    2004-01-01

    Full Text Available Analisou-se a associação entre gravidez precoce e as repercussões emocionais negativas para a adolescente, segundo variáveis sócio-demográficas e psicossociais. Foram entrevistadas 1.228 adolescentes em maternidades do Município do Rio de Janeiro. Avaliou-se as repercussões emocionais por meio das variáveis autovalorização negativa, pouca ou nenhuma expectativa frente ao futuro e sofrimento psíquico. O teste do chi2 e a Odds Ratio foram usadas para análise dos dados. As adolescentes que referiram uma reação negativa da família se sentiram menos valorizadas (OR 1,8, com poucas expectativas em relação ao futuro (OR 2,3 e manifestaram grande sofrimento psíquico (OR 1,5. As que estavam fora da escola quando engravidaram tiveram também uma pior autovalorização (OR 1,9 e menores expectativas em relação ao futuro (OR 2,2. Um grande nível de sofrimento psíquico relacionou-se inversamente à freqüência ao pré-natal (0,7. Pode-se concluir que o suporte familiar, independente da condição social de origem, foi identificado neste estudo como o principal fator minimizador das repercussões emocionais negativas da gestação na adolescência.This study analyzed the association between early pregnancy and negative emotional repercussions for adolescents, according to socio-demographic and psychosocial variables. The study interviewed 1,228 adolescents in maternity hospitals in the City of Rio de Janeiro. Emotional repercussions were evaluated with negative self-assessment variables, showing little or no expectation towards the future, as well as psychological distress. The chi2 test and odds ratio were used to analyze the data. Adolescents who reported a negative reaction by the family felt less valued (OR 1.8, with little expectation towards the future (OR 2.3, and presented major psychological distress (OR 1.5. Those not enrolled in school when they became pregnant also showed worse self-esteem (OR 1.9 and fewer expectations

  7. Wisconsin Air Cargo Study

    Science.gov (United States)

    2011-04-01

    Air cargo is a key economic lifeline for the communities that have airports. Manufacturers, businesses, hospitals and : other community cornerstone employers depend on air cargo to successfully operate. While there is no doubt that air : cargo repres...

  8. Baltimore Air Toxics Study (BATS)

    Energy Technology Data Exchange (ETDEWEB)

    Sullivan, D.A. [Sullivan Environmental Consulting, Inc., Alexandria, VA (United States)

    1996-12-31

    The Baltimore Air Toxics Study is one of the three urban air toxics initiatives funded by EPA to support the development of the national air toxics strategy. As part of this project, the Air Quality Integrated Management System (AIMS) is under development. AIMS is designed to bring together the key components of urban air quality management into an integrated system, including emissions assessment, air quality modeling, and air quality monitoring. Urban area source emissions are computed for a wide range of pollutants and source categories, and are joined with existing point source emissions data. Measured air quality data are used to evaluate the adequacy of the emissions data and model treatments as a function of season, meteorological parameters, and daytime/nighttime conditions. Based on tested model performance, AIMS provides the potential to improve the ability to predict air quality benefits of alternative control options for criteria and toxic air pollutants. This paper describes the methods used to develop AIMS, and provides examples from its application in the Baltimore metropolitan area. The use of AIMS in the future to enhance environmental management of major industrial facilities also will be addressed in the paper.

  9. Infants Can Study Air Science.

    Science.gov (United States)

    Ward, Alan

    1983-01-01

    Provided are activities and demonstrations which can be used to teach infants about the nature of air, uses of air, and objects that fly in the air. The latter include airships, hot-air balloons, kites, parachutes, airplanes, and Hovercraft. (JN)

  10. Promoting anti-corruption reforms. Evaluating the implementation of a World Bank anti-corruption program in seven African countries (1999-2001)

    NARCIS (Netherlands)

    Klein Haarhuis, C.M.

    2005-01-01

    This study offers an investigation of the implementation of a World Bank anti-corruption program, by applying various relevant social science theories and methods. The aim of the program is to provide countries with tools to build a relevant and participatory anti-corruption program. The study

  11. Promoting anti-corruption reforms : Evaluating the implementation of a World Bank anti-corruption program in seven African countries (1999-2001)

    NARCIS (Netherlands)

    Klein Haarhuis, Carolien Maria

    2005-01-01

    This study offers an investigation of the implementation of a World Bank anti-corruption program, by applying various relevant social science theories and methods. The aim of the program is to provide countries with tools to build a relevant and participatory anti-corruption program. The study

  12. Interaction patterns of major air pollutants in Hong Kong territory

    International Nuclear Information System (INIS)

    Lu, W.Z.; Wang, X.K.

    2004-01-01

    Air pollution in a metropolitan city like Hong Kong is a major obstacle to improve air quality and living environment due to the high population density and the vehicle emission increases. The high air pollutant levels impose harm to the human health and impair the city image. The characteristic analysis of air pollutants is very important and necessary to pollutant monitoring, forecasting and controlling. In this study, the interaction patterns of principle air pollutants, e.g. nitrogen dioxide (NO 2 ), nitric oxide (NO), nitric oxides (NO x ) and ozone (O 3 ), a secondary pollutant, are investigated based on the measured database in four selected areas, which covers two urban types (i.e. residential area, mixed residential/commercial/industrial area) in Hong Kong, during the period of 1999-2001. The study involves analyzing the chemical and physical properties, the characteristics of air pollutants and the factors affecting such interactions using statistical method. The results reveal several routines in urban air pollutants' variations, interaction and trends from macro aspect

  13. The use of brain CT Scan in craniocerebral trauma with Glasgow coma scale scores of 13 – 15 in Dr. Cipto Mangunkusumo Hospital 1999-2001

    Directory of Open Access Journals (Sweden)

    Jofizal Jannis

    2004-09-01

    Full Text Available There is still a controversy among the neurologists whether brain CT scan must be performed on the mild head trauma patients. This study was executed to find out the correlation between the brain CT scan image findings and its clinical impairment among the mild head trauma patients with Glasgow coma scale (GCS score of 13 to 15. The study was a retrospective study by analyzing the uniform medical records of the head trauma patients hospitalized at the Neurology ward of Dr. Cipto Mangunkusumo Hospital within the period of 1999 to 2001. During that period 1,663 patients were hospitalized due to head trauma, and 1,166 of them (70.1 % were suffered from mild head trauma patients with GCS score of 13-15. Among those with brain CT scan examinations (N: 271, the neurological abnormalities were found on 144 (53.1% of patients, consisted of cerebral edema (11,4%, intracerebral hemorrhage (5.5%, epidural hemorrhage (16.2%, subdural hemorrhage (18.1%, subarachnoid hemorrhage (5.5%, and combination (13.8%. The further analysis showed that cranial nerves disturbance, amnesia, loss of conciousness for more than 10 minutes, and vomiting are significantly correlated to the brain CT scan abnormality. Combination of the above four clinical signs and symptoms have sensitivity of 90 % in predicting brain insults. This findings may be used as a simple set of clinical criteria for identifying mild head trauma patients who need undergo CT scan examination. (Med J Indones 2004; 13: 156-60 Keywords: mild head injury, brain CT scan

  14. Water-quality characteristics of quaternary unconsolidated-deposit aquifers and lower tertiary aquifers of the Bighorn Basin, Wyoming and Montana, 1999-2001

    Science.gov (United States)

    Bartos, Timothy T.; Eddy-Miller, Cheryl A.; Norris, Jody R.; Gamper, Merry E.; Hallberg, Laura L.

    2004-01-01

    As part of the Yellowstone River Basin National Water Quality Assessment study, ground-water samples were collected from Quaternary unconsolidated-deposit and lower Tertiary aquifers in the Bighorn Basin of Wyoming and Montana from 1999 to 2001. Samples from 54 wells were analyzed for physical characteristics, major ions, trace elements, nutrients, dissolved organic carbon, radionuclides, pesticide compounds, and volatile organic compounds (VOCs) to evaluate current water-quality conditions in both aquifers. Water-quality samples indicated that waters generally were suitable for most uses, and that natural conditions, rather than the effects of human activities, were more likely to limit uses of the waters. Waters in both types of aquifers generally were highly mineralized, and total dissolved-solids concentrations frequently exceeded the U.S. Environmental Protection Agency (USEPA) Secondary Maximum Contaminant Level (SMCL) of 500 milligrams per liter (mg/L). Because of generally high mineralization, waters from nearly one-half of the samples from Quaternary aquifers and more than one-half of the samples from lower Tertiary aquifers were not classified as fresh (dissolved-solids concentration were not less than 1,000 mg/L). The anions sulfate, fluoride, and chloride were measured in some ground-water samples at concentrations greater than SMCLs. Most waters from the Quaternary aquifers were classified as very hard (hardness greater than 180 mg/L), but hardness varied much more in waters from the lower Tertiary aquifers and ranged from soft (less than 60 mg/L) to very hard (greater than 180 mg/L). Major-ion chemistry varied with dissolved-solids concentrations. In both types of aquifers, the predominant anion changes from bicarbonate to sulfate with increasing dissolved-solids concentrations. Samples from Quaternary aquifers with fresh waters generally were calcium-bicarbonate, calcium-sodium-bicarbonate, and calcium-sodium-sulfate-bicarbonate type waters, whereas

  15. Portland cement concrete air content study.

    Science.gov (United States)

    1987-04-20

    This study took the analysis of Portland cement concrete air content. Based on the information gathered, this study hold the results were : 1) air-entrained concrete was more durable than non-air entrained concrete all other factors being equal; 2) A...

  16. Air Quality Case Studies Report

    Science.gov (United States)

    1995-08-01

    The Federal Highway Administration (FHWA) recognizes that many metropolitan areas are struggling with how to respond adequately to the 1990 Clean Air Act Amendments (CAAA) and the 1991 Intermodal Surface Transportation Efficiency Act (ISTEA), particu...

  17. Aplicación del método captura-recaptura en la evaluación del sistema de vigilancia epidemiológica de la enfermedad meningocócica en Tenerife (1999-2001

    Directory of Open Access Journals (Sweden)

    Ana Izquierdo Carreño

    2003-01-01

    Full Text Available Fundamento: La vigilancia de la Enfermedad Meningocócica en Canarias es fundamentalmente pasiva, sirviéndose del circuito habitual de las Enfermedades de Declaración Obligatoria. El objetivo de este trabajo incluye describir los atributos cualitativos y cuantitativos del sistema y evaluar la exhaustividad mediante el sistema de captura-recaptura de tres fuentes de información. Métodos:El estudio abarca los años 1999-2001 en Tenerife. La información se obtuvo de tres fuentes: el Sistema de las Enfermedades de Declaración Obligatoria, los Laboratorios de Microbiología y el Conjunto Mínimo Básico de Datos hospitalario. Se aplicaron los Protocolos de Evaluación de un Sistema de Vigilancia de los Centers of Disease Control and Prevention, de Atlanta. Para la estimación del número de casos se usó un modelo log-linear. Los cálculos de la exhaustividad y los intervalos de confianza al 95% se realizaron en el paquete estadístico SPSS10. Resultados:La sensibilidad del sistema resultó ser del 84,9% y el valor predictivo positivo del 80,4%. El retraso en la notificación (oportunidad osciló entre los 0,5 y 13 días, con una mediana de 3 días. La aceptabilidad global del sistema ha sido del 76,64%. El valor de la exhaustividad fue del 98,1%. Conclusiones: La vigilancia de esta enfermedad es buena, con una sensibilidad que hablaría de un buen nivel de declaración, reafirmada por la exhaustividad. Aunque el valor predictivo positivo es alto, podría apuntar hacia la rápida instauración de tratamiento antibiótico que impediría la confirmación microbiológica. El sistema es oportuno, permitiendo la rápida adopción de medidas de intervención.

  18. Aplicación del método captura-recaptura en la evaluación del sistema de vigilancia epidemiológica de la enfermedad meningocócica en Tenerife (1999-2001

    Directory of Open Access Journals (Sweden)

    Izquierdo Carreño Ana

    2003-01-01

    Full Text Available Fundamento: La vigilancia de la Enfermedad Meningocócica en Canarias es fundamentalmente pasiva, sirviéndose del circuito habitual de las Enfermedades de Declaración Obligatoria. El objetivo de este trabajo incluye describir los atributos cualitativos y cuantitativos del sistema y evaluar la exhaustividad mediante el sistema de captura-recaptura de tres fuentes de información. Métodos: El estudio abarca los años 1999-2001 en Tenerife. La información se obtuvo de tres fuentes: el Sistema de las Enfermedades de Declaración Obligatoria, los Laboratorios de Microbiología y el Conjunto Mínimo Básico de Datos hospitalario. Se aplicaron los Protocolos de Evaluación de un Sistema de Vigilancia de los Centers of Disease Control and Prevention, de Atlanta. Para la estimación del número de casos se usó un modelo log-linear. Los cálculos de la exhaustividad y los intervalos de confianza al 95% se realizaron en el paquete estadístico SPSS10. Resultados: La sensibilidad del sistema resultó ser del 84,9% y el valor predictivo positivo del 80,4%. El retraso en la notificación (oportunidad osciló entre los 0,5 y 13 días, con una mediana de 3 días. La aceptabilidad global del sistema ha sido del 76,64%. El valor de la exhaustividad fue del 98,1%. Conclusiones: La vigilancia de esta enfermedad es buena, con una sensibilidad que hablaría de un buen nivel de declaración, reafirmada por la exhaustividad. Aunque el valor predictivo positivo es alto, podría apuntar hacia la rápida instauración de tratamiento antibiótico que impediría la confirmación microbiológica. El sistema es oportuno, permitiendo la rápida adopción de medidas de intervención.

  19. Study of air traffic over KLFIR

    Science.gov (United States)

    Nusyirwan, I. F.; Rohani, J. Mohd

    2017-12-01

    This paper shares the overview of the work currently being conducted with the Department of Civil Aviation Malaysia related to the air traffic. The aim is to study air traffic performance over KL and KK FIR, and the area of interest in this paper is the Kuala Lumpur Flight Information Region (KLFIR). The air traffic performance parameters includes general air traffic movement such as level allocation, number of movements, sector load analysis and also more specific parameters such as airborne delays, effects of weather to the air movements as well as ground delays. To achieve this, a huge effort has been undertaken that includes live data collection algorithm development and real time statistical analysis algorithm development. The main outcome from this multi-disciplinary work is the long-term analysis on the air traffic performance in Malaysia, which will put the country at par in the aviation community, namely the International Civil Aviation Organization (ICAO).

  20. Perfil sócio-demográfico e psicossocial de puérperas adolescentes do Município do Rio de Janeiro, Brasil - 1999-2001 A socioeconomic and psychosocial profile of post-partum adolescents in the City of Rio de Janeiro, Brazil, 1999-2001

    Directory of Open Access Journals (Sweden)

    Adriane Reis Sabroza

    2004-01-01

    Full Text Available Identificar o perfil sócio-demográfico de puérperas adolescentes, segundo a faixa etária e a situação conjugal. Foram entrevistadas 1.228 adolescentes no pós-parto imediato em maternidades públicas, conveniadas com o SUS e privadas do Município do Rio de Janeiro. A análise estatística consistiu em utilizar testes qui-quadrado (chi2 para testar hipóteses de homogeneidade de proporções. Ao comparar os dois grupos, observa-se que as adolescentes mais jovens e sem união consensual estão mais sujeitas a engravidar de outros adolescentes, muitos dos quais desempregados; a não desejar a gestação; a não receber apoio familiar ou do pai do bebê e a realizar mais tentativas de aborto. A aderência às consultas pré-natais foi influenciada pela presença de uma união consensual. As adolescentes com menos idade e sem união consensual demonstraram maior insatisfação com a gestação, e a união conjugal influenciou positivamente a maneira como a gestação foi percebida pela família e pela própria adolescente. Os resultados obtidos revelam que as adolescentes em idade mais precoce e sem união consensual apresentam piores condições sócio-demográficas e psicossociais.This study aimed to describe the socioeconomic and psychosocial characteristics of a sample of teenage mothers classified according to marital status and age group. A sample of 1,228 adolescent mothers was interviewed in the immediate post-partum, selected from public and private hospitals in the City of Rio de Janeiro, Brazil. The chi-square test (chi2 was used to verify the hypothesis of homogeneity of proportions. Comparing the groups, we found that single and younger adolescents were at increased risk of unwanted pregnancy, less family support, and more abortions. Fathers of the infants also tended to be adolescents and unemployed. Adherence to prenatal care was influenced by the adolescent's marital status. The results showed that the most disadvantaged

  1. Advances in Understanding Air Pollution and Cardiovascular Diseases: The Multi-Ethnic Study of Atherosclerosis and Air Pollution (MESA Air)

    Science.gov (United States)

    Kaufman, Joel D.; Spalt, Elizabeth W.; Curl, Cynthia L.; Hajat, Anjum; Jones, Miranda R.; Kim, Sun-Young; Vedal, Sverre; Szpiro, Adam A.; Gassett, Amanda; Sheppard, Lianne; Daviglus, Martha L.; Adar, Sara D.

    2016-01-01

    The Multi-Ethnic Study of Atherosclerosis and Air Pollution (MESA Air) leveraged the platform of the MESA cohort into a prospective longitudinal study of relationships between air pollution and cardiovascular health. MESA Air researchers developed fine-scale, state-of-the-art air pollution exposure models for the MESA Air communities, creating individual exposure estimates for each participant. These models combine cohort-specific exposure monitoring, existing monitoring systems, and an extensive database of geographic and meteorological information. Together with extensive phenotyping in MESA—and adding participants and health measurements to the cohort—MESA Air investigated environmental exposures on a wide range of outcomes. Advances by the MESA Air team included not only a new approach to exposure modeling but also biostatistical advances in addressing exposure measurement error and temporal confounding. The MESA Air study advanced our understanding of the impact of air pollutants on cardiovascular disease and provided a research platform for advances in environmental epidemiology. PMID:27741981

  2. Controlled air incinerator conceptual design study

    International Nuclear Information System (INIS)

    1982-01-01

    This report presents a conceptual design study for a controlled air incinerator facility for incineration of low level combustible waste at Three Mile Island Unit 2 (TMI-2). The facility design is based on the use of a Helix Process Systems controlled air incinerator. Cost estimates and associated engineering, procurement, and construction schedules are also provided. The cost estimates and schedules are presented for two incinerator facility designs, one with provisions for waste ash solidification, the other with provisions for packaging the waste ash for transport to an undefined location

  3. Study of air pollution in Buenos Aires city. Appendix 1

    International Nuclear Information System (INIS)

    Pla, R.R.; Moreno, M.A.; Tafuri, V.; Cussto, G.S.; Adler, M.

    1995-01-01

    The work performed since 1993 on the study of the elemental profile of Buenos Aires atmosphere is presented. Both aerosol direct sampling and biomonitors have been used and the samples have been analyzed mainly by Instrumental Neutron Activation Analysis (INAA). Due to problems with XRF, Anodic Stripping Voltammetry has been chosen for lead determination and Ion Chromatography for soluble anions. For aerosol direct sampling, analytical and sampling methods are described, as well as the sampling campaigns. Experiments have been performed for studying differences between day/night elemental concentrations along the week and a possible seasonal dependence. Some results of mass concentrations and others from INAA are presented. Sampling with the 'Gent sampler' began during August 1994 at an urban residential area of the city. The results of mass concentrations for the first 28 pairs of samples are shown together with some INAA results, as this is the only technique used for the analysis. Lichens and tree bark were the chosen biomonitors. Sampling and analytical methods by INAA are exposed, presenting some of the results that have been obtained. The participation in the aerosol analysis for the Ushuaia Global Atmospheric Watch Station is also commented. (author)

  4. Civil Air Patrol (CAP) Aircraft Requirement Study

    National Research Council Canada - National Science Library

    Mercher, Christopher

    1999-01-01

    The Air Force Audit Agency (AFAA) concluded in its Report of Audit EB0980013 (13 May 98), Air Force Oversight of CY 1996 Civil Air Patrol Corporation Activities, CAP-USAF, Maxwell AFB, AL 36112-6323...

  5. Elemental bioaccumulators in air pollution studies

    International Nuclear Information System (INIS)

    Freitas, M.C.

    1995-01-01

    K 0 -Based instrumental neutron activation analysis (k 0 INAA) was used to determine the concentrations of Cr, Fe, Co, Zn, Se, Sb and Hg in the vascular plants Cistus salvifolius and Inula viscosa and in the lichen Parmelia sulcata. The samples were collected in the neighbourhood of industrial complexes. The elemental accumulation in the vascular plants and the lichen are compared to optimize the choice of the bioaccumulator. It is concluded that P.sulcata seems to be the best accumulator of the three species for the element studied; Cistus salvifolius is sensitive to the contents of Zn, Fe, Cr and Sb in the air; Inula viscosa seems to accumulate Fe, Sb, Co, Cr and Zn. Nevertheless, it is concluded that lichen is a good air pollution indicator, while the vascular plants are not due to the large seasonal variations found in the elemental concentrations. (author) 11 refs.; 7 figs.; 2 tabs

  6. Study of urban air pollution in Thailand

    International Nuclear Information System (INIS)

    Chueinta, W.; Bunprapob, S.; Suksamran, C.; Sirinuntavid, A.

    2004-01-01

    The Office of Atoms for Peace has conducted a monitoring study of urban air pollution in Thailand for years. The primary objective of the project was to support the use of nuclear-related techniques for research and monitoring studies on air pollution. The databases obtained have been analyzed and interpreted by statistical methods including source identification using receptor model. This paper reports the work of 2002 at a heavy traffic area in Bangkok. A Gent sampler was set at the curbside of a major road in Bangkok to collect fine and coarse particles routinely on a weekday for 24 hours, once a week. The filter samples were analyzed for elemental concentrations by use of instrumental neutron activation analysis. Black carbon was separately determined by means of the reflectance measurement of the filter sample. In the report, the methodologies and the results of analyses of fine and coarse particles on filters collected in 2002 are presented. The study of the applicability of certified reference material was done by analyses of two standard reference materials provided by JAERI, i.e., NIST 1632c and NIES No.8. The comparisons of the measured and certified values are also given in the paper. (author)

  7. Experimental studies of the air hybrid engine charging operation

    OpenAIRE

    Zhao, H; Ma, T; Lee, CY

    2014-01-01

    Over the last few years, theoretical and modelling studies have been carried out on the feasibility and potential of novel mild air hybrid engine concepts based on production components. These mild air hybrid concepts are able to convert vehicle brake energy into pneumatic energy in the form of compressed air stored in the air tank. The compressed air can then be used to crank-start the engine by either injecting and expanding in the cylinder or driving a production air starter. Thus, the reg...

  8. Los Alamos controlled-air incineration studies

    International Nuclear Information System (INIS)

    Koenig, R.A.; Warner, C.L.

    1983-01-01

    Current regulations of the Environmental Protection Agency (EPA) require that PCBs in concentrations greater than 500 ppM be disposed of in EPA-permitted incinerators. Four commercial incineration systems in the United States have EPA operating permits for receiving and disposing of concentrated PCBs, but none can accept PCBs contaminated with nuclear materials. The first section of this report presents an overview of an EPA-sponsored program for studying PCB destruction in the large-scale Los Alamos controlled-air incinerator. A second major FY 1983 program, sponsored by the Naval Weapons Support Center, Crane, Indiana, is designed to determine operating conditions that will destroy marker smoke compounds without also forming polycyclic aromatic hydrocarbons (PAHs), some of which are known or suspected to be carcinogenic. We discuss the results of preliminary trial burns in which various equipment and feed formulations were tested. We present qualitative analyses for PAHs in the incinerator offgas as a result of these tests

  9. Interactions between particulate air pollution and temperature in air pollution mortality time series studies

    International Nuclear Information System (INIS)

    Roberts, Steven

    2004-01-01

    In many community time series studies on the effect of particulate air pollution on mortality, particulate air pollution is modeled additively. In this study, we investigated the interaction between daily particulate air pollution and daily mean temperature in Cook County, Illinois and Allegheny County, Pennsylvania, using data for the period 1987-1994. This was done through the use of joint particulate air pollution-temperature response surfaces and by stratifying the effect of particulate air pollution on mortality by temperature. Evidence that the effect of particulate air pollution on mortality may depend on temperature is found. However, the results were sensitive to the number of degrees of freedom used in the confounder adjustments, the particulate air pollution exposure measure, and how the effects of temperature on mortality are modeled. The results were less sensitive to the estimation method used--generalized linear models and natural cubic splines or generalized additive models and smoothing splines. The results of this study suggest that in community particulate air pollution mortality time series studies the possibility of an interaction between daily particulate air pollution and daily mean temperature should be considered

  10. Effects of radon in indoor air studied

    International Nuclear Information System (INIS)

    Auvinen, A.

    1994-01-01

    Radon is an odorless, tasteless and colourless radioactive noble gas that enters indoor air from the ground. Radon causes lung cancer. A committee set up to evaluate the health risks of chemical substances has been drafting a report on radon, which will compile the major research findings on the lung cancer risk posed by radon. Animal tests have shown that even small doses of radon can cause lung cancer. Smokers seem to contract radon-induced lung cancer more readily than non-smokers. Because research findings have been conflicting, however, it is not known exactly how high the risk of lung cancer caused by indoor radon exposure really is. Several major research projects are under way to obtain increasingly accurate risk assessments. An on-going European joint project brings together several studies - some already finished, some still being worked on. In this way it will be possible to get more accurate risk assessments than from individual studies. In order to prevent lung cancer, it is important to continue the work of determining and reducing radon connects and to combat smoking. (orig.)

  11. Summary of surface-water-quality data collected for the Northern Rockies Intermontane Basins National Water-Quality Assessment Program in the Clark Fork-Pend Oreille and Spokane River basins, Montana, Idaho, and Washington, water years 1999-2001

    Science.gov (United States)

    Beckwith, Michael A.

    2003-01-01

    Water-quality samples were collected at 10 sites in the Clark Fork-Pend Oreille and Spokane River Basins in water years 1999 – 2001 as part of the Northern Rockies Intermontane Basins (NROK) National Water-Quality Assessment (NAWQA) Program. Sampling sites were located in varied environments ranging from small streams and rivers in forested, mountainous headwater areas to large rivers draining diverse landscapes. Two sampling sites were located immediately downstream from the large lakes; five sites were located downstream from large-scale historical mining and oreprocessing areas, which are now the two largest “Superfund” (environmental remediation) sites in the Nation. Samples were collected during a wide range of streamflow conditions, more frequently during increasing and high streamflow and less frequently during receding and base-flow conditions. Sample analyses emphasized major ions, nutrients, and selected trace elements. Streamflow during the study ranged from more than 130 percent of the long-term average in 1999 at some sites to 40 percent of the long-term average in 2001. River and stream water in the study area exhibited small values for specific conductance, hardness, alkalinity, and dissolved solids. Dissolved oxygen concentrations in almost all samples were near saturation. Median total nitrogen and total phosphorus concentrations in samples from most sites were smaller than median concentrations reported for many national programs and other NAWQA Program study areas. The only exceptions were two sites downstream from large wastewater-treatment facilities, where median concentrations of total nitrogen exceeded the national median. Maximum concentrations of total phosphorus in samples from six sites exceeded the 0.1 milligram per liter threshold recommended for limiting nuisance aquatic growth. Concentrations of arsenic, cadmium, copper, lead, mercury, and zinc were largest in samples from sites downstream from historical mining and ore

  12. Study of containment air cooler capacity in steam air environment during accident conditions

    International Nuclear Information System (INIS)

    Kansal, M.; Mohan, N.; Bhawal, R.N.; Bajaj, S.S.

    2002-01-01

    Full text: The air coolers are provided for controlling the temperature in the reactor building during normal operation. These air coolers also serve as the main heat sink for the removal of energy from high enthalpy air-steam mixture expected in reactor building under accident conditions. A subroutine COOLER has been developed to estimate the heat removal rate of the air coolers at high temperature and steam conditions. The subroutine COOLER has been attached with the code PACSR (post accident containment system response) used for containment pressure temperature calculation. The subroutine was validated using design parameters at normal operating condition. A study was done to estimate the heat removal rate for some postulated accident conditions. The study reveals that, under accident conditions, the heat removal rate of air coolers increases several times compared with normal operating conditions

  13. Peacekeeping in the Congo, 1999-2001: Success or Failure?

    Science.gov (United States)

    2014-05-22

    War. President Nelson Mandela was the chairman of the South African Development Community (SADC) in the summer of 1998 when the war broke out in the...DRC. President Mandela attempted to use his influence to bring peace to the region. On 3 September 1998, after high-level SADC meetings, President... Mandela announced the community’s support for the military interventions by its member states in the DRC conflict. President Mandela and his

  14. Wind Turbine Lightning Protection Project: 1999-2001

    Energy Technology Data Exchange (ETDEWEB)

    McNiff, B.

    2002-05-01

    A lightning protection research and support program was instituted by NREL to help minimize lightning damage to wind turbines in the United States. This paper provides the results of a field test program, an evaluation of protection on selected turbines, and a literature search as well as the dissemination of the accumulated information.

  15. WATER QUALITY ASSESSMENT OF LAKE TEXOMA BEACHES, 1999-2001

    Science.gov (United States)

    A biological and inorganic assessment of five beaches on Lake Texoma was conducted from September 1999 through July 2001. Water samples for each beach site were divided into two groups, a swimming season and non-swimming season. Water properties such as temperature, alkalinity,...

  16. Experimental study on air cleaning effect of clean air heat pump and its impact on ventilation requirement

    DEFF Research Database (Denmark)

    Fang, Lei; Sheng, Ying; Nie, Jinzhe

    2017-01-01

    This study investigated air purification effect of a Clean-Air Heat Pump (CAHP) which combined a desiccant wheel with a heat pump for both air cleaning and HVAC of buildings. The experiment was conducted in a field lab at four different outdoor air supply rates with and without air cleaning by CAHP....... Both sensory assessments of perceived air quality and chemical measurements of TVOC concentrations were conducted for evaluating the air cleaning performance of the CAHP. The results of experiment showed that running the CAHP improved significantly perceived air quality. At 2 L/s per person of outdoor...... air supply rate with operating the CAHP, the air quality was equivalent to the value at the higher outdoor air supply rate of 10 L/s per person without running CAHP. The TVOC measurements observed over 92% of efficiency on removal of indoor air VOCs and no VOCs accumulation on the desiccant wheel...

  17. Experimental Setup For Study of Drop Deformation In Air Flow

    Directory of Open Access Journals (Sweden)

    Basalaev Sergey

    2017-01-01

    Full Text Available Experimental study for study of deformation of drops in air flow is considered. Experimental setup includes a module for obtaining the drops, an air flow system and measuring system. Module for formation of drops is in the form of vertically arranged dropper with capillary with the possibility of formation of fixed drops. Air flow supply system comprises an air pump coupled conduit through a regulating valve with a cylindrical pipe, installed coaxially with dropper. The measuring system includes the video camera located with possibility of visualization of drop and the Pitot gage for measurement of flow rate of air located in the output section of branch pipe. This experimental setup allows to provide reliable and informative results of the investigation of deformation of drops in the air flow.

  18. Public Perception of Urban Air Pollution: An Exploratory Study

    International Nuclear Information System (INIS)

    Sala, R.; Oltra, C.; Goncalves, L.

    2014-01-01

    This report presents the results of a qualitative study using focus groups aimed at understanding the beliefs and attitudes of the population towards air pollution, its levels, causes, health impacts and possible mitigation and protection actions. The study sample consisted of members of the general population, between 18 and 65 years living in Barcelona. The analysis of the group discussion indicates that there is little awareness among participants about air pollution risks. The causes of air pollution are relatively known but there is little knowledge about pollution levels and types of pollutants. We found a low level of perceived personal risk associated to air pollution that coexists with a general awareness of the health impacts of air pollution, a low level of concern about the problem and a low level of personal involvement in mitigation and self protection measures. Participants reported no use of existing information services about air pollution. (Author)

  19. Clean indoor air increases physical independence : a pilot study

    NARCIS (Netherlands)

    Snijders, M.C.L.; Koren, L.G.H.; Kort, H.S.M.; Bronswijk, van J.E.M.H.

    2001-01-01

    Clean indoor air enhances health. In a pilot study, we examined whether a good indoor air quality increases the activity potential of older persons with chronic lung disease. Five older persons were studied while performing kitchen activities. Body movement and heart rate were monitored.

  20. [Study on emission standard system of air pollutants].

    Science.gov (United States)

    Jiang, Mei; Zhang, Guo-Ning; Zhang, Ming-Hui; Zou, Lan; Wei, Yu-Xia; Ren, Chun

    2012-12-01

    Scientific and reasonable emission standard system of air pollutants helps to systematically control air pollution, enhance the protection of the atmospheric environment effect and improve the overall atmospheric environment quality. Based on the study of development, situation and characteristics of national air pollutants emission standard system, the deficiencies of system were pointed out, which were not supportive, harmonious and perfect, and the improvement measures of emission standard system were suggested.

  1. Urban air pollution, study of Mexico City

    Energy Technology Data Exchange (ETDEWEB)

    Bauer, M [PUE-UNAM (Mexico); Guzman, F [Inst. Mexicano del Petroleo (Mexico); Navarro, B [Univ. Autonoma Metropolitana (Mexico)

    1996-12-01

    The Metropolitan Area of Mexico City (MAMC) is an outstanding case of a fast urban development with lagging, and thus insufficient, massive transportation facilities. This has given rise to a distorted transportation system that accounts for most of the air pollution problem of the city and constitutes a drag on economic development. In this paper, we first describe the MAMC geographical conditions, its growth in physical and economic terms, its transportation system, the ensuring air pollution problems together with some of the mitigation actions undertaken. Afterwards the results of a survey of the displacements of individuals within the city and the time spent on these are presented, to then draw some considerations on the negative economic impact it represents. (EG)

  2. Study of the air fluorescence by AIRFLY

    Czech Academy of Sciences Publication Activity Database

    Boháčová, Martina

    2009-01-01

    Roč. 190, May (2009), s. 266-271 ISSN 0920-5632. [Cosmic Ray International Seminar 2008. Malfa, 15.09.2008-19.09.2008] R&D Projects: GA MŠk(CZ) LA08016; GA MŠk(CZ) 1M06002 Institutional research plan: CEZ:AV0Z10100502; CEZ:AV0Z10100522 Keywords : air fluorescence * cosmic rays Subject RIV: BF - Elementary Particles and High Energy Physics

  3. Rural southeast Texas air quality measurements during the 2006 Texas Air Quality Study.

    Science.gov (United States)

    Schade, Gunnar W; Khan, Siraj; Park, Changhyoun; Boedeker, Ian

    2011-10-01

    The authors conducted air quality measurements of the criteria pollutants carbon monoxide, nitrogen oxides, and ozone together with meteorological measurements at a park site southeast of College Station, TX, during the 2006 Texas Air Quality Study II (TexAQS). Ozone, a primary focus of the measurements, was above 80 ppb during 3 days and above 75 ppb during additional 8 days in summer 2006, suggestive of possible violations of the ozone National Ambient Air Quality Standard (NAAQS) in this area. In concordance with other air quality measurements during the TexAQS II, elevated ozone mixing ratios coincided with northerly flows during days after cold front passages. Ozone background during these days was as high as 80 ppb, whereas southerly air flows generally provided for an ozone background lower than 40 ppb. Back trajectory analysis shows that local ozone mixing ratios can also be strongly affected by the Houston urban pollution plume, leading to late afternoon ozone increases of as high as 50 ppb above background under favorable transport conditions. The trajectory analysis also shows that ozone background increases steadily the longer a southern air mass resides over Texas after entering from the Gulf of Mexico. In light of these and other TexAQS findings, it appears that ozone air quality is affected throughout east Texas by both long-range and regional ozone transport, and that improvements therefore will require at least a regionally oriented instead of the current locally oriented ozone precursor reduction policies.

  4. Indoor Air Quality and Student Performance [and Case Studies].

    Science.gov (United States)

    Environmental Protection Agency, Washington, DC. Office of Radiation and Indoor Air.

    This report examines how indoor air quality (IAQ) affects a child's ability to learn and provides several case studies of schools that have successfully addressed their indoor air problems, the lessons learned from that experience, and what long-term practices and policies emerged from the effort. The report covers the effects from…

  5. Respirators: Air Purifying, Self-Study, Course 40723

    Energy Technology Data Exchange (ETDEWEB)

    Chochoms, Michael [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-12-21

    Respirators: Air Purifying Self-Study (COURSE 40723) is designed for Los Alamos National Laboratory (LANL) workers, support services subcontractors, and other LANL subcontractors who work under the LANL Respiratory Protection Program (RPP). This course also meets the air-purifying respirators (APRs) retraining requirement.

  6. Air pollution and health studies in China--policy implications.

    Science.gov (United States)

    Chen, Bingheng; Kan, Haidong; Chen, Renjie; Jiang, Songhui; Hong, Chuanjie

    2011-11-01

    During the rapid economic development in China, ambient air pollutants in major cities, including PM10 (particulate matter with aerodynamic diameter air pollution levels in China are still at the higher end of the world level. Less information is available regarding changes in national levels of other pollutants such as PM2.5 and ozone. The Chinese Ministry of Environmental Protection (MOEP) set an index for "controlling/reducing total SO2 emissions" to evaluate the efficacy of air pollution control strategy in the country. Total SO2 emissions declined for the first time in 2007. Chinese epidemiologic studies evidenced adverse health effects of ambient air pollution similar to those reported from developed countries, though risk estimates on mortality/morbidity per unit increase of air pollutant are somewhat smaller than those reported in developed countries. Disease burden on health attributable to air pollution is relatively greater in China because of higher pollution levels. Improving ambient air quality has substantial and measurable public health benefits in China. It is recommended that the current Chinese air quality standards be updated/revised and the target for "controlling/reducing total SO2 emissions" be maintained and another target for "reducing total NO2 emissions" be added in view of rapid increase in motor vehicles. Continuous and persistent efforts should be taken to improve ambient air quality.

  7. Studies on ultraviolet inactivation of air-borne microorganisms, 1

    International Nuclear Information System (INIS)

    Adachi, Shin-ichi; Doi, Hitoshi; Yamayoshi, Takao; Nunoura, Masako; Tatsumi, Noriyuki.

    1989-01-01

    UV(254nm) inactivation of air-borne bacteria in an air-controlling apparatus was studied. The appratus was composed of a chamber for vaporizing a bacterial suspension and an irradiation duct equipped with an UV lamp(GL-30). The bacterial which passed through the irradiation duct impinged on a petri dish by an air slit sampler. Selected bacteria for the experiment were Serratia marcescens, Escherichia coli, Sarcina lutea and Bacillus subtilis(spores). The apparatus was useful for the study of the susceptibility of air-borne bacteria to UV radiation. UV dose necessary to inhibit colony formation in 90% of individual bacteria in the controlled air was as low as 27 to 35% of the dose required for the agar plate method. (author)

  8. [Experimental study on spectra of compressed air microwave plasma].

    Science.gov (United States)

    Liu, Yong-Xi; Zhang, Gui-Xin; Wang, Qiang; Hou, Ling-Yun

    2013-03-01

    Using a microwave plasma generator, compressed air microwave plasma was excited under 1 - 5 atm pressures. Under different pressures and different incident microwave power, the emission spectra of compressed air microwave plasma were studied with a spectra measuring system. The results show that continuum is significant at atmospheric pressure and the characteristic will be weakened as the pressure increases. The band spectra intensity will be reduced with the falling of the incident microwave power and the band spectra were still significant. The experimental results are valuable to studying the characteristics of compressed air microwave plasma and the generating conditions of NO active groups.

  9. The Lavelle Affair: An Air Force Case Study in Ethics

    Science.gov (United States)

    2016-06-01

    THE LAVELLE AFFAIR: AN AIR FORCE CASE STUDY IN ETHICS BY KRISTINA ELLIS A THESIS PRESENTED TO THE FACULTY OF THE SCHOOL OF... ethical transgressions. As such, the story of General Lavelle’s wartime command experiences became a case study in ethics and integrity within Air...1 1 THE LIFE AND CAREER OF GENERAL LAVELLE 8 1 VIETNAM 14 2 CIVIL-MILITARY RELATIONS 25 2 ETHICAL

  10. Air pollution and sick-leaves. A case study using air pollution data from Oslo

    International Nuclear Information System (INIS)

    Hansen, A.C.; Selte, H.K.

    2000-01-01

    During the last decade an increasing amount of studies have investigated the relationship between air pollution and human health effects. In this study we investigate how these effects in turn induce reduced labour productivity in terms of sick-leaves, which is an important factor in assessment of air pollution costs in urban areas. For this purpose we employ a logit model along with data on sick-leaves from a large office in Oslo and different air pollutants. Our results indicate that sick-leaves are significantly associated with particulate matter (PM 1 0), while the associations with SO 2 and NO 2 are more ambiguous. We also try to estimate the induced social costs in terms of lost labour productivity and increased governmental expenditures, although these estimates are more uncertain. 17 refs

  11. Analysis of air temperature and relative humidity: study of microclimates

    OpenAIRE

    Elis Dener Lima Alves; Marcelo Sacardi Biudes

    2012-01-01

    Understanding the variability of climate elements in time and space is fundamental to the knowledge of the dynamics of microclimate. Thus, the objective was to analyze the variability of air temperature and relative humidity on the Cuiabá campus of the Federal University of Mato Grosso, and, through the clustering technique, to analyze the formation of groups to propose a zoning microclimate in the area study. To this end, collection data of air temperature and relative humidity at 15 points ...

  12. Studies of urban climates and air pollution in Switzerland

    International Nuclear Information System (INIS)

    Wanner, H.; Hertig, J.

    1984-01-01

    In addition to an assessment of the factors that are responsible for urban climate change, this paper describes climatological studies and peculiarities of some Swiss cities. Although these cities are small, urban air pollution presents a real problem for urban planning. This is a result of the narow street canyons, the high traffic concentration and the complex topography, which favors air stagnation during anticyclonic weather conditions

  13. Mobile Air Quality Studies (MAQS-an international project

    Directory of Open Access Journals (Sweden)

    Sudik Claudia

    2010-04-01

    Full Text Available Abstract Due to an increasing awareness of the potential hazardousness of air pollutants, new laws, rules and guidelines have recently been implemented globally. In this respect, numerous studies have addressed traffic-related exposure to particulate matter using stationary technology so far. By contrast, only few studies used the advanced technology of mobile exposure analysis. The Mobile Air Quality Study (MAQS addresses the issue of air pollutant exposure by combining advanced high-granularity spatial-temporal analysis with vehicle-mounted, person-mounted and roadside sensors. The MAQS-platform will be used by international collaborators in order 1 to assess air pollutant exposure in relation to road structure, 2 to assess air pollutant exposure in relation to traffic density, 3 to assess air pollutant exposure in relation to weather conditions, 4 to compare exposure within vehicles between front and back seat (children positions, and 5 to evaluate "traffic zone"-exposure in relation to non-"traffic zone"-exposure. Primarily, the MAQS-platform will focus on particulate matter. With the establishment of advanced mobile analysis tools, it is planed to extend the analysis to other pollutants including NO2, SO2, nanoparticles and ozone.

  14. Bioventing and air sparging: a field research study

    International Nuclear Information System (INIS)

    Moore, B.J.; Armstrong, J.E.; Hardisty, P.E.; Dupont, R.R.

    1997-01-01

    A study was conducted at Gulf Canada Resources' Strachan Gas Plant in Alberta, in which bioventing and air sparging were used individually and in combination to remediate a free-phase natural gas condensate plume estimated to cover approximately 65,000 m 2 . The condensate was composed of light hydrocarbons. Benzene, toluene, ethylbenzene and total xylenes (BTEX) made up a large portion of the dissolved plume. The objectives of the bioventing program were to: (1) study the use of biodegradation respiration rates and hydrocarbon vapour concentrations as indicators of soil clean-up progress, (2) study the effectiveness of bioventing during winter operations, (3) assess the degree of soil clean-up achievable through bioventing, and (4) evaluate the economics of bioventing. It was shown that bioventing is an economical in-situ remediation technique, costing about $10/m 3 . Air sparging involves the injection of air below the groundwater table to remove dissolved phased contaminants in-situ. The objectives of the air sparging program were to: (1) determine the zone of influence achievable through air sparging, (2) assess bioventing for treating hydrocarbon vapours introduced into the unsaturated zone during sparging, and (3) evaluate hydrocarbon mass removal effectiveness due to volatilization and biodegradation. It was shown that 90 per cent of the saturated zone hydrocarbon mass was removed during eight months of air sparging. 11 refs., 1 tab., 5 figs

  15. Participant evaluation results for two indoor air quality studies

    International Nuclear Information System (INIS)

    Hawthorne, A.R.; Dudney, C.S.; Cohen, M.A.; Spengler, J.D.

    1987-01-01

    After two surveys for indoor air pollutants (radon and other chemicals) the homeowners were surveyed for their reactions. The results of these participant evaluation surveys, assuming that the participants that responded to the survey were representative, indicate that homeowners will accept a significant level of monitoring activity as part of an indoor air quality field study. Those participants completing surveys overwhelmingly enjoyed being in the studies and would do it again. We believe that the emphasis placed on positive homeowner interactions and efforts made to inform participants throughout our studies were positive factors in this result. There was no substantial differences noted in the responses between the 70-house study, which included a homeowner compensation payment of $100, and the 300-house study, which did not include a compensation payment. These results provide encouragement to conduct future complex, multipollutant indoor air quality studies when they are scientifically sound and cost effective

  16. Conceptual study on air ingress mitigation for VHTRs

    International Nuclear Information System (INIS)

    Oh, Chang H.; Kim, Eung Soo

    2012-01-01

    Highlights: ► Important factors that affect air-ingress process in the VHTRs were investigated and identified. ► Two air ingress mitigation concepts were developed using a root-cause analysis. ► These concepts were validated using computational fluid dynamic method. ► In-vessel helium injection and ex-vessel enclosure concept will mitigate air-ingress effectively. - Abstract: An air ingress accident following a postulated pipe break is considered a critical event for a very high temperature gas-cooled reactor (VHTR) safety. Following helium depressurization, it is anticipated that air will enter the core through the break leading to oxidation of the in-core graphite structures. Under extreme circumstances and without mitigation features this accident may lead to exothermic chemical reactions between graphite and oxygen depending on the accident scenario and the design. Under extreme circumstances (beyond design basis), a loss of structural integrity may occur in some core structures and lead to elevated release of radiological inventory for the fuel matrix. This paper discusses various air ingress mitigation concepts applicable for the VHTRs that would prevent core damage even in the most extreme scenarios. The study begins with identifying important factors (or phenomena) associated with the air ingress accident using root-cause analysis. By preventing main causes of the important events identified in the root-cause diagram, the basic air ingress mitigation ideas were conceived and developed. Among them, two concepts were finally evaluated as effective candidates. One concept is to inject helium directly into the lower plenum (direct in-vessel injection); the other concept is to enclose the reactor with a non-pressure boundary with an opening at the bottom (ex-vessel enclosure). Computational fluid dynamics (CFD) methods were used to evaluate these concepts for proof of these principles. Results indicate that both concepts can effectively suppress air

  17. Conceptual study on air ingress mitigation for VHTRs

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Chang H., E-mail: Chang.Oh@inl.gov [Idaho National Laboratory, P.O. Box 1625, Idaho Falls, ID 83415-3870 (United States); Kim, Eung Soo [Department of Nuclear Engineering, Seoul National University, 559 Gwanak-ro, Gwanak-gu, Seoul (Korea, Republic of)

    2012-09-15

    Highlights: Black-Right-Pointing-Pointer Important factors that affect air-ingress process in the VHTRs were investigated and identified. Black-Right-Pointing-Pointer Two air ingress mitigation concepts were developed using a root-cause analysis. Black-Right-Pointing-Pointer These concepts were validated using computational fluid dynamic method. Black-Right-Pointing-Pointer In-vessel helium injection and ex-vessel enclosure concept will mitigate air-ingress effectively. - Abstract: An air ingress accident following a postulated pipe break is considered a critical event for a very high temperature gas-cooled reactor (VHTR) safety. Following helium depressurization, it is anticipated that air will enter the core through the break leading to oxidation of the in-core graphite structures. Under extreme circumstances and without mitigation features this accident may lead to exothermic chemical reactions between graphite and oxygen depending on the accident scenario and the design. Under extreme circumstances (beyond design basis), a loss of structural integrity may occur in some core structures and lead to elevated release of radiological inventory for the fuel matrix. This paper discusses various air ingress mitigation concepts applicable for the VHTRs that would prevent core damage even in the most extreme scenarios. The study begins with identifying important factors (or phenomena) associated with the air ingress accident using root-cause analysis. By preventing main causes of the important events identified in the root-cause diagram, the basic air ingress mitigation ideas were conceived and developed. Among them, two concepts were finally evaluated as effective candidates. One concept is to inject helium directly into the lower plenum (direct in-vessel injection); the other concept is to enclose the reactor with a non-pressure boundary with an opening at the bottom (ex-vessel enclosure). Computational fluid dynamics (CFD) methods were used to evaluate these concepts

  18. Air

    International Nuclear Information System (INIS)

    Gugele, B.; Scheider, J.; Spangl, W.

    2001-01-01

    In recent years several regulations and standards for air quality and limits for air pollution were issued or are in preparation by the European Union, which have severe influence on the environmental monitoring and legislation in Austria. This chapter of the environmental control report of Austria gives an overview about the legal situation of air pollution control in the European Union and in specific the legal situation in Austria. It gives a comprehensive inventory of air pollution measurements for the whole area of Austria of total suspended particulates, ozone, volatile organic compounds, nitrogen oxides, sulfur dioxide, carbon monoxide, heavy metals, benzene, dioxin, polycyclic aromatic hydrocarbons and eutrophication. For each of these pollutants the measured emission values throughout Austria are given in tables and geographical charts, the environmental impact is discussed, statistical data and time series of the emission sources are given and legal regulations and measures for an effective environmental pollution control are discussed. In particular the impact of fossil-fuel power plants on the air pollution is analyzed. (a.n.)

  19. A study of air breathing rockets. 3: Supersonic mode combustors

    Science.gov (United States)

    Masuya, G.; Chinzel, N.; Kudo, K.; Murakami, A.; Komuro, T.; Ishii, S.

    An experimental study was made on supersonic mode combustors of an air breathing rocket engine. Supersonic streams of room-temperature air and hot fuel-rich rocket exhaust were coaxially mixed and burned in a concially diverging duct of 2 deg half-angle. The effect of air inlet Mach number and excess air ratio was investigated. Axial wall pressure distribution was measured to calculate one dimensional change of Mach number and stagnation temperature. Calculated results showed that supersonic combustion occurred in the duct. At the exit of the duct, gas sampling and Pitot pressure measurement was made, from which radial distributions of various properties were deduced. The distribution of mass fraction of elements from rocket exhaust showed poor mixing performance in the supersonic mode combustors compared with the previously investigated cylindrical subsonic mode combustors. Secondary combustion efficiency correlated well with the centerline mixing parameter, but not with Annushkin's non-dimensional combustor length. No major effect of air inlet Mach number or excess air ratio was seen within the range of conditions under which the experiment was conducted.

  20. Performance of air sparging systems -- A review of case studies

    International Nuclear Information System (INIS)

    Bass, D.H.; Brown, R.A.

    1995-01-01

    In situ air sparging is a commonly used remediation technology which volatilizes and enhances aerobic biodegradation of contamination in Groundwater and saturated zone soil. Recently, some questions have been raised regarding the effectiveness of air sparging. To address these questions the results of 21 sparging case studies have been compiled to shed light on how well air sparging achieves permanent reduction in groundwater contaminant concentrations. The case studies included both chlorinated solvents and petroleum hydrocarbon contamination, and covered a wide range of soil conditions and sparge system parameters. In each case study, groundwater concentrations were compared before sparging was initiated, just before sparging was terminated, and in the months following shutdown of the sparging system

  1. Acute effect of ambient air pollution on stroke mortality in the China air pollution and health effects study.

    Science.gov (United States)

    Chen, Renjie; Zhang, Yuhao; Yang, Chunxue; Zhao, Zhuohui; Xu, Xiaohui; Kan, Haidong

    2013-04-01

    There have been no multicity studies on the acute effects of air pollution on stroke mortality in China. This study was undertaken to examine the associations between daily stroke mortality and outdoor air pollution (particulate matter air pollution with daily stroke mortality. Air pollution was associated with daily stroke mortality in 8 Chinese cities. In the combined analysis, an increase of 10 μg/m(3) of 2-day moving average concentrations of particulate matter air pollution and risk of stroke mortality. To our knowledge, this is the first multicity study in China, or even in other developing countries, to report the acute effect of air pollution on stroke mortality. Our results contribute to very limited data on the effect of air pollution on stroke for high-exposure settings typical in developing countries.

  2. Economic and technical feasibility study of compressed air storage

    Energy Technology Data Exchange (ETDEWEB)

    1976-03-01

    The results of a study of the economic and technical feasibility of compressed air energy storage (CAES) are presented. The study, which concentrated primarily on the application of underground air storage with combustion turbines, consisted of two phases. In the first phase a general assessment of the technical alternatives, economic characteristics and the institutional constraints associated with underground storage of compressed air for utility peaking application was carried out. The goal of this assessment was to identify potential barrier problems and to define the incentive for the implementation of compressed air storage. In the second phase, the general conclusions of the assessment were tested by carrying out the conceptual design of a CAES plant at two specific sites, and a program of further work indicated by the assessment study was formulated. The conceptual design of a CAES plant employing storage in an aquifer and that of a plant employing storage in a conventionally excavated cavern employing a water leg to maintain constant pressure are shown. Recommendations for further work, as well as directions of future turbo-machinery development, are made. It is concluded that compressed air storage is technically feasible for off-peak energy storage, and, depending on site conditions, CAES plants may be favored over simple cycle turbine plants to meet peak demands. (LCL)

  3. The Gulf of Mexico air quality study: An industry perspective

    International Nuclear Information System (INIS)

    Shannon, B.E.

    1994-01-01

    Section 328 of the Clean Air Act Amendments of 1990 required the EPA to promulgate a rule establishing air pollution control requirements for Outer Continental Shelf (OCS) sources. Congress exempted Gulf of Mexico OCS sources west of 87.5 degrees longitude (near the border of Alabama and Florida) pending the results of a ''three year'' study conducted by the Department of Interior (DOI) - Minerals Management Service (MMS). The study required an examination of the impacts of emissions from OCS activities in such areas that fail to meet the National Ambient Air Quality Standard (NAAQS) for either ozone or nitrogen dioxide. This paper reviews the MMS Gulf of Mexico Air Quality Study's (GMAQS) emission inventory development, historical ozone episode modeling, field sampling, and preliminary photochemical modeling results. Industry has developed a standardized spreadsheet to calculate emissions and a software package to allow operators to figure out the cost to control OCS sources for NO x and VOCs under the EPA's OCS Air Regulations (40 CFR Part 55). Cost estimates are provided for various regulatory scenarios currently being reviewed by the EPA and MMS

  4. Study of electric discharges between moving electrodes in air

    International Nuclear Information System (INIS)

    Andreev, V. V.; Pichugin, Yu. P.; Telegin, V. G.; Telegin, G. G.

    2011-01-01

    A barrier electric discharge excited between a fixed electrode and a rotating electrode covered with a dielectric layer in atmospheric-pressure air is studied experimentally. A distinctive feature of this type of discharge is that it operates at a constant voltage between the electrodes. An advantage of the proposed method for plasma generation in the boundary layer of the rotating electrode (e.g., for studying the influence of plasma on air flows) is the variety of forms of the discharge and conditions for its initiation, simplicity of the design of the discharge system, and ease of its practical implementation

  5. Study of electric discharges between moving electrodes in air

    Energy Technology Data Exchange (ETDEWEB)

    Andreev, V. V.; Pichugin, Yu. P.; Telegin, V. G.; Telegin, G. G. [Chuvash State University (Russian Federation)

    2011-12-15

    A barrier electric discharge excited between a fixed electrode and a rotating electrode covered with a dielectric layer in atmospheric-pressure air is studied experimentally. A distinctive feature of this type of discharge is that it operates at a constant voltage between the electrodes. An advantage of the proposed method for plasma generation in the boundary layer of the rotating electrode (e.g., for studying the influence of plasma on air flows) is the variety of forms of the discharge and conditions for its initiation, simplicity of the design of the discharge system, and ease of its practical implementation.

  6. Air Pollution Exposure Modeling for Health Studies | Science ...

    Science.gov (United States)

    Dr. Michael Breen is leading the development of air pollution exposure models, integrated with novel personal sensor technologies, to improve exposure and risk assessments for individuals in health studies. He is co-investigator for multiple health studies assessing the exposure and effects of air pollutants. These health studies include participants with asthma, diabetes, and coronary artery disease living in various U.S. cities. He has developed, evaluated, and applied novel exposure modeling and time-activity tools, which includes the Exposure Model for Individuals (EMI), GPS-based Microenvironment Tracker (MicroTrac) and Exposure Tracker models. At this seminar, Dr. Breen will present the development and application of these models to predict individual-level personal exposures to particulate matter (PM) for two health studies in central North Carolina. These health studies examine the association between PM and adverse health outcomes for susceptible individuals. During Dr. Breen’s visit, he will also have the opportunity to establish additional collaborations with researchers at Harvard University that may benefit from the use of exposure models for cohort health studies. These research projects that link air pollution exposure with adverse health outcomes benefit EPA by developing model-predicted exposure-dose metrics for individuals in health studies to improve the understanding of exposure-response behavior of air pollutants, and to reduce participant

  7. Studies on air ingress for pebble bed reactors

    International Nuclear Information System (INIS)

    Moore, R.L.; Oh, C.H.; Merrill, B.J.; Petti, D.A.

    2002-01-01

    A loss-of-coolant accident (LOCA) has been considered a critical event for helium-cooled pebbled bed reactors. Following helium depressurization, it is anticipated that unless countermeasures are taken air will enter the core through the break and then by molecular diffusion and ultimately by natural convection leading to oxidation of the in-core graphite structure and graphite pebbles. Thus, without any mitigating features a LOCA will lead to an air ingress event. The INEEL is studying such an event with two well-respected light water reactor transient response codes: RELAP5/ATHENA and MELCOR. To study the degree of graphite oxidation occurring due to an air ingress event, a MELCOR model of a reference pebble bed design was constructed. A modified version of MELCOR developed at INEEL, which includes graphite oxidation capabilities, and molecular diffusion of air into helium was used for these calculations. Results show that the lower reflector graphite consumes all of the oxygen before reaching the core. The results also show a long time delay between the time that the depressurization phase of the accident is over and the time that natural circulation air through the core occurs. (author)

  8. Motor vehicle-related air toxics study. Final report

    International Nuclear Information System (INIS)

    1993-04-01

    Section 202 (1)(1) of the Clean Air Act (CAA), as amended (Section 206 of the Clean Air Act Amendments) (CAAA) of 1990 added paragraph (1) to Section 202 of the (CAA), directs the Environmental Protection Agency (EPA) to complete a study by May 15, 1992 of the need for, and feasibility of, controlling emissions of toxic air pollutants which are unregulated under the Act and associated with motor vehicles and motor vehicle fuels. The report has been prepared in response to Section 202 (1)(1). Specific pollutants or pollutant categories which are discussed in the report include benezene, formaldehyde, 1,3-butadiene, acetaldehyde, diesel particulate matter, gasoline particulate matter, and gasoline vapors as well as certain of the metals and motor vehicle-related pollutants identified in Section 112 of the Clean Air Act. The focus of the report is on carcinogenic risk. The study attempts to summarize what is known about motor vehicle-related air toxics and to present all significant scientific opinion on each issue

  9. Study of air pollution in Chile using biomonitors

    International Nuclear Information System (INIS)

    Cortes, E.; Gras, N.; Guzman, G.; Pereira, I.

    1999-01-01

    A project has been undertaken within the framework of a Co-ordinated Research Programme (CRP) supported by the International Atomic Energy Agency (IAEA) to carry out a long term study on atmospheric air pollution in Chile using biomonitors. The present project aims at the selection of appropriate plants and other indicators for monitoring of air pollution in several cities and rural areas in Chile. Nuclear analytical techniques, in particular neutron activation analysis (NAA) will be used complemented by AAS for the analysis of selected elements and to determine the sources of pollutants and the applicability of biomonitors to study air pollution in large areas, using indicators either naturally grown or artificially introduced to the region under examination. (author)

  10. Air Pollution Exposure Modeling for Epidemiology Studies and Public Health

    Science.gov (United States)

    Air pollution epidemiology studies of ambient fine particulate matter (PM2.5) often use outdoor concentrations as exposure surrogates. These surrogates can induce exposure error since they do not account for (1) time spent indoors with ambient PM2.5 levels attenuated from outdoor...

  11. Activation of coagulation system during air travel: a crossover study

    NARCIS (Netherlands)

    Schreijer, A. J. M.; Cannegieter, S. C.; Meijers, J. C. M.; Middeldorp, S.; Büller, H. R.; Rosendaal, F. R.

    2006-01-01

    BACKGROUND: There is an increased risk of venous thrombosis after air travel, but the underlying mechanism is unclear. Our aim was to ascertain whether flying leads to a hypercoagulable state. METHODS: We did a crossover study in 71 healthy volunteers (15 men, 56 women), in whom we measured markers

  12. Radon diffusion studies in air, gravel, sand, soil and water

    International Nuclear Information System (INIS)

    Singh, B.; Singh, S.; Virk, H.S.

    1993-01-01

    Radon isotopes are practically inert and have properties of gases under conditions of geological interest. During their brief lives their atoms are capable of moving from sites of their generation. Radon diffusion studies were carried out in air, gravel, sand, soil and water using silicon diffused junction electronic detector, Alphameter-400. Diffusion constant and diffusion length is calculated for all these materials. (author)

  13. Methodological issues in studies of air pollution and reproductive health.

    Science.gov (United States)

    Woodruff, Tracey J; Parker, Jennifer D; Darrow, Lyndsey A; Slama, Rémy; Bell, Michelle L; Choi, Hyunok; Glinianaia, Svetlana; Hoggatt, Katherine J; Karr, Catherine J; Lobdell, Danelle T; Wilhelm, Michelle

    2009-04-01

    In the past decade there have been an increasing number of scientific studies describing possible effects of air pollution on perinatal health. These papers have mostly focused on commonly monitored air pollutants, primarily ozone (O(3)), particulate matter (PM), sulfur dioxide (SO(2)), carbon monoxide (CO), and nitrogen dioxide (NO(2)), and various indices of perinatal health, including fetal growth, pregnancy duration, and infant mortality. While most published studies have found some marker of air pollution related to some types of perinatal outcomes, variability exists in the nature of the pollutants and outcomes associated. Synthesis of the findings has been difficult for various reasons, including differences in study design and analysis. A workshop was held in September 2007 to discuss methodological differences in the published studies as a basis for understanding differences in study findings and to identify priorities for future research, including novel approaches for existing data. Four broad topic areas were considered: confounding and effect modification, spatial and temporal exposure variations, vulnerable windows of exposure, and multiple pollutants. Here we present a synopsis of the methodological issues and challenges in each area and make recommendations for future study. Two key recommendations include: (1) parallel analyses of existing data sets using a standardized methodological approach to disentangle true differences in associations from methodological differences among studies; and (2) identification of animal studies to inform important mechanistic research gaps. This work is of critical public health importance because of widespread exposure and because perinatal outcomes are important markers of future child and adult health.

  14. Vaal Triangle air pollution health study. Addressing South African problems

    Energy Technology Data Exchange (ETDEWEB)

    Terblanche, P; Nel, R [CSIR Environmental Services, Pretoria (South Africa); Surridge, T [Dept. of Mineral and Energy Affairs (South Africa); Annegarn, H [Annegarn Environmental Research, Johannesburg (South Africa); Tosen, G [Eskom, Johannesburg (South Africa); Pols, A [CSIR Informationtek, Pretoria (South Africa)

    1996-12-31

    Situated in the central region of South Africa, the Vaal Triangle is an area which plays a vital role in driving the economic dynamo of South Africa. Also, because of the concentration of heavy industry, it is an area which provides a challenge in effective air pollution control. The Vaal Triangle lies within the Vaal River Basin, at an altitude of 1 500 m above sea level. Meteorological conditions in the area are highly conducive to the formation of surface temperature inversions, resulting in a poor dispersion potential. Because of multiple sources of air pollution in the area, poor dispersion conditions increase the risk pollution build-up and subsequent adverse impacts. The situation is further exacerbated by the continued combustion of coal in households, even after the electrification of residences. This is particularly chronic in the developing communities and during winter. Vaal Triangle Air Pollution Health Study (VAPS) was initiated in 1990 by the Department of Health, the Medical Research Council and major industries in the area to determine effects of air pollution on the health of the community. The final results of that study summarised in this article, and options to ameliorate problems are addressed. (author)

  15. Vaal Triangle air pollution health study. Addressing South African problems

    Energy Technology Data Exchange (ETDEWEB)

    Terblanche, P.; Nel, R. [CSIR Environmental Services, Pretoria (South Africa); Surridge, T. [Dept. of Mineral and Energy Affairs (South Africa); Annegarn, H. [Annegarn Environmental Research, Johannesburg (South Africa); Tosen, G. [Eskom, Johannesburg (South Africa); Pols, A. [CSIR Informationtek, Pretoria (South Africa)

    1995-12-31

    Situated in the central region of South Africa, the Vaal Triangle is an area which plays a vital role in driving the economic dynamo of South Africa. Also, because of the concentration of heavy industry, it is an area which provides a challenge in effective air pollution control. The Vaal Triangle lies within the Vaal River Basin, at an altitude of 1 500 m above sea level. Meteorological conditions in the area are highly conducive to the formation of surface temperature inversions, resulting in a poor dispersion potential. Because of multiple sources of air pollution in the area, poor dispersion conditions increase the risk pollution build-up and subsequent adverse impacts. The situation is further exacerbated by the continued combustion of coal in households, even after the electrification of residences. This is particularly chronic in the developing communities and during winter. Vaal Triangle Air Pollution Health Study (VAPS) was initiated in 1990 by the Department of Health, the Medical Research Council and major industries in the area to determine effects of air pollution on the health of the community. The final results of that study summarised in this article, and options to ameliorate problems are addressed. (author)

  16. Air dan Konflik: Studi Kasus Kabupaten Timor Tengah Selatan

    Directory of Open Access Journals (Sweden)

    Hary Jocom

    2016-04-01

    / water conflict, but did not occur in the context of the community in the district Kolbano and Kualin, and other areas in the district TTS.   Keywords: Conflict, natural resources, water resources, water scarcity Cara sitasi: Jocom, H., Kameo, D.D., Utami, I., dan Kristijanto, A.I. (2016. Air dan Konflik: Studi Kasus Kabupaten Timor Tengah Selatan. Jurnal Ilmu Lingkungan. 14(1,51-61, doi:10.14710/jil.14.1.51-61

  17. Long-term effects of traffic-related air pollution on mortality in a Dutch cohort (NLCS-AIR study)

    NARCIS (Netherlands)

    Beelen, R.; Hoek, G.; Brandt, P.A. van den; Goldbohm, R.A.; Fischer, P.; Schouten, L.J.; Jerrett, M.; Hughes, E.; Armstrong, B.; Brunekreef, B.

    2008-01-01

    Background: Several studies have found an effect on mortality of between-city contrasts in long-term exposure to air pollution. The effect of within-city contrasts is still poorly understood. Objectives: We studied the association between long-term exposure to traffic-related air pollution and

  18. Theoretical study for solar air pretreatment collector/regenerator

    Energy Technology Data Exchange (ETDEWEB)

    Peng Donggen; Zhang Xiaosong; Yin Yonggao [School of Energy and Environment, Southeast Univ., Nanjing (China)

    2008-07-01

    A new liquid regeneration equipment - solar air pretreatment collector/regenerator for liquid desiccant cooling system is put forward in this paper, which is preferable to solution regeneration in hot and moist climate in South China. The equipment can achieve liquid regeneration in lower temperature. When the solution and the air are in ''match'' state in collector/ regenerator, a match air to salt mass ratio ASMR* is found by theoretical study in which there is the largest theoretical storage capacity SC{sub max}. After two new concepts of the effective solution proportion (EPS) and the effective storage capacity (ESC) are defined, it is found by theoretical calculation that when ESP drops from 100% to 67%, ESC raises lowly, not drops and liquid outlet concentration C{sub str} {sub sol} increases from 40% to 49% in which its increment totals to 90%. All these data explain fully that air pretreatment liquid regeneration equipment enables to improve the performance of liquid desiccant cooling system. (orig.)

  19. Comparison of Descemet stripping under continuous air flow, manual air injection and balanced salt solution for DMEK: a pilot study.

    Science.gov (United States)

    Gabbay, I E; Bahar, I; Nahum, Y; Livny, E

    2017-08-01

    Descemet's membrane endothelial keratoplasty (DMEK) involves removal of the recipient's Descemet membrane (DM) prior to transplanting the donor's DM. When using balanced salt solution (BSS) or ophthalmic viscosurgical devices (OVDs), visualization of the host's DM during its stripping may be inadequate and may result in Descemet remnants and could lead to sub-optimal surgical results. Previous articles described excellent visualization when utilizing air injection but this requires repeated air injection into the anterior chamber (AC). We present a pilot study that compares different techniques under which DM stripping can be performed: with continuous automated air infusion, with manual air infusion, and with BSS. We retrospectively compared video footage of DM stripping with BSS, with continuous air and with manual injection of air into the AC to determine DM stripping duration and the number of times the surgeon had to insert and retrieve a surgical instrument from the AC. Thirty videos of 10 consecutive cases of the three DM stripping techniques were evaluated. DM stripping duration was 3.26 (±1.32), 3.92 (±1.2) and 12.9 (±3.98) minutes for BSS, continuous air flow, and manual air injection, respectively. Frequency of instrument retrieval (FIR) was 3.6 (±1.71), 1.5 (±0.71) and 15.1 (±3.28) for BSS, continuous air flow, and manual air injection, respectively. Continuous air flow and BSS were both statistically different than manual air injection into the AC (p air in the AC contributes to better visualization and an efficient surgery.

  20. STUDY OF THE AIR FLOWS AROUND AN AIRPLANE

    Directory of Open Access Journals (Sweden)

    Diaconescu Olivian

    2013-06-01

    Full Text Available This material presents a stage of the designing of an airplane capable to work with low capacity engines of 2.5 and 4 cmc namely the simulation of the air flow around the fuselage and the wings. The study proves the correctness of the choice made in the wing’s positioning and of the horizontal stabilizer of the airplane’s axis,for the chosen airplane type namely acrobat.

  1. STUDY OF THE AIR FLOWS AROUND AN AIRPLANE

    OpenAIRE

    Diaconescu Olivian

    2013-01-01

    This material presents a stage of the designing of an airplane capable to work with low capacity engines of 2.5 and 4 cmc namely the simulation of the air flow around the fuselage and the wings. The study proves the correctness of the choice made in the wing’s positioning and of the horizontal stabilizer of the airplane’s axis,for the chosen airplane type namely acrobat.

  2. Hybrid Air Quality Modeling Approach For Use in the Near-Road Exposures to Urban Air Pollutant Study (NEXUS)

    Science.gov (United States)

    The Near-road EXposures to Urban air pollutant Study (NEXUS) investigated whether children with asthma living in close proximity to major roadways in Detroit, MI, (particularly near roadways with high diesel traffic) have greater health impacts associated with exposure to air pol...

  3. Valdez air health study - Exposure monitoring and risk assessment

    International Nuclear Information System (INIS)

    Murray, D.R.; Mikkelsen, R.

    1991-01-01

    In Valdez, Alaska there is concern about exposure of the public to benzene and other light hydrocarbons emitted during the loading of tankers from the Trans-Alaska Pipeline. As part of an overall risk assessment, the Valdez Air Health Study, a personal, indoor and outdoor air sampling program patterned after EPA's TEMA Study was designed and carried out. A unique feature of the study is that, during sampling periods, SF 6 tracer was released at the terminal site to represent terminal hydrocarbon emissions to provide a basis for directly quantitating any contribution of terminal emissions to personal exposure. Sixty citizens at Valdez were selected to wear vests containing sampling equipment for 24-hour periods summer and winter. At the homes of 30 of the participants simultaneous indoor and outdoor samples for hydrocarbons and tracer were collected during the period that each participant collected personal air samples. The paper reviews the design of the program, details of the procedures used, results of the August, 1990 program and preliminary results from the February-March, 1991 program

  4. Study on sampling conditions for the monitoring of waste air

    International Nuclear Information System (INIS)

    Moeller, T.J.; Buetefisch, K.A.

    1998-01-01

    The technical codes for radiological monitoring of the waste air released from a radwaste repository demand that sampling for determination of aerosol-borne radioactivity is to be made with a screener equipped with a suitable number of measuring probes extending over the entire cross-sectional surface of the vent. Another requirement is to ensure that the waste air stream passing through the measuring channel is representative, containing the typical, operation-induced distribution of aerosols across the surface to be scanned. The study reported was intended to determine in a scaled-down model (1:10) of a repository ventilating duct the typical spatial distribution of aerosols (3D particulate density) in order to establish information on the type of typical distributions of aerosols, to be used for optimisation of the measuring site and monitoring instruments. (orig./CB) [de

  5. Study of air pollution scavenging. Fourteenth progress report

    Energy Technology Data Exchange (ETDEWEB)

    Semonin, R.G.

    1976-04-01

    The field experiments were continued to estimate convective storm particulate scavenging efficiency in proximity to the St. Louis, Missouri urban-industrial complex. Complementary studies of the urban aerosol characterization, source strength, and removal processes were also studied. The 1975 field effort shifted emphasis from the immediate St. Louis area to the Alton-Wood River industrial complex. Along with the change in size and configuration of the network, there were increases in the numbers of most types of samplers. The new network yielded the following types of samples for analysis and interpretation: 1065 total rain samples from 85 sites; 68 sequential rainwater samples from 2 locations; 272 wet/dry samples from 7 locations; 216 air filter samples from 7 locations; 36 air filter samples from aircraft; and raindrop spectrometer data from 11 sites for the period 17 June-18 August. The analysis procedures require that all water samples undergo filtering for separate analyses of soluble and insoluble fractions of the elemental concentrations. This data collection effort provided a record number of samples for chemical analysis. Approximately 4000 pibals and over 370 radiosondes were released in the operational period, providing wind and thermodynamic data on 33 days. Aircraft missions were flown on 24 days, with one air tracer release of cesium on 19 July 1975. The status of the analysis of all types of data is described.

  6. Plant air systems safety study: Portsmouth Gaseous Diffusion Plant

    International Nuclear Information System (INIS)

    1982-05-01

    The Portsmouth Gaseous Diffusion Plant Air System facilities and operations are reviewed for potential safety problems not covered by standard industrial safety procedures. Information is presented under the following section headings: facility and process description (general); air plant equipment; air distribution system; safety systems; accident analysis; plant air system safety overview; and conclusion

  7. A Study on establishment of air preservation policy strategy in 21st century

    Energy Technology Data Exchange (ETDEWEB)

    Han, Hwa Jin; Kang, Kwang Kyu; Yoon, Jung Im [Korea Environment Institute, Seoul (Korea)

    1998-12-01

    For the air preservation and entire global environmental preservation in 21st century, it was implemented as a pre-work to maintain clean and clear air quality and to prepare a preventive air preservation policy. This study was focused on proposing the basic strategy of air preservation policy by deriving problems and evaluating actual results. 34 refs., 2 figs., 43 tabs.

  8. Assessment on air quality pattern: a case study in Putrajaya, Malaysia

    African Journals Online (AJOL)

    Nowadays, air quality problem has become a major issue in Malaysia for the past two decades, This study aims to determine the pattern of the air quality status, investigate the significant pollutant, relationship between air pollutants and API and evaluate the pattern of air pollution. Data from Putrajaya monitoring station ...

  9. Air Quality in Lanzhou, a Major Industrial City in China: Characteristics of Air Pollution and Review of Existing Evidence from Air Pollution and Health Studies

    Science.gov (United States)

    Zhang, Yaqun; Li, Min; Bravo, Mercedes A.; Jin, Lan; Nori-Sarma, Amruta; Xu, Yanwen; Guan, Donghong; Wang, Chengyuan; Chen, Mingxia; Wang, Xiao; Tao, Wei; Qiu, Weitao; Zhang, Yawei

    2015-01-01

    Air pollution contributes substantially to global health burdens; however, less is known about pollution patterns in China and whether they differ from those elsewhere. We evaluated temporal and spatial heterogeneity of air pollution in Lanzhou, an urban Chinese city (April 2009–December 2012), and conducted a systematic review of literature on air pollution and health in Lanzhou. Average levels were 141.5, 42.3, and 47.2 µg/m3 for particulate matter with an aerodynamic diameter ≤10 µm (PM10), NO2, and SO2, respectively. Findings suggest some seasonality, particularly for SO2, with higher concentrations during colder months relative to warmer months, although a longer time frame of data is needed to evaluate seasonality fully. Correlation coefficients generally declined with distance between monitors, while coefficients of divergence increased with distance. However, these trends were not statistically significant. PM10 levels exceeded Chinese and other health-based standards and guidelines. The review identified 13 studies on outdoor air pollution and health. Although limited, the studies indicate that air pollution is associated with increased risk of health outcomes in Lanzhou. These studies and the high air pollution levels suggest potentially serious health consequences. Findings can provide guidance to future epidemiological studies, monitor placement programs, and air quality policies. PMID:25838615

  10. Report of study 7.3: cooling and air conditioning

    Energy Technology Data Exchange (ETDEWEB)

    Russo, F.

    2000-07-01

    This report describes the results of the study carried out by the study group 7.3 in the triennium 1997-2000. The study was focused on industrial refrigeration and air conditioning for the large building utilising natural gas. The goal of this study, carried out in collaboration of the members of study group 7.3, was to analyse the markets of industrial refrigeration and air conditioning for large buildings to identify possibilities to increase the natural gas share in these sectors. The available technology in the two sectors of the market are described in a single section, i.e. the 'State of the art of the technology'. In this section, technical characteristics, applications, performances, new developments and others topics are discussed for absorbers, gas engines, gas turbines and fuel cells. In the 'Industrial Refrigeration' section an analysis of the present global market for the industrial sector is presented. Economics, advantages and barriers to gas units compared with the electrical units are discussed. Information on existing industrial plants, possible application options and new technology developments are described as well. The 'Air conditioning for the large building' section deals with offices, hotels, commercial buildings, hospitals and shopping centres with a cooling capacity of 350 kW or higher. It appears that the use of natural gas for cooling of large buildings has been increasing during the last decade, thanks to the greater availability of natural gas and the development of new technologies. A marketing survey of gas air-conditioning was carried out in cooperation with a group of Intergas Marketing. Based on the survey, the report describes the market position of natural gas relative to electricity. It provides the strategic prospects for further developing natural gas as a competitive option for air-conditioning of large buildings using a combination of state-of-the-art technologies. It is important to highlight

  11. Air Force Nuclear Enterprise Organization: A Case Study

    Science.gov (United States)

    2016-09-15

    changes. To address the objectives of this study, five investigative questions ( IQ ) are posed: IQ1. What constitutes the Air Force Nuclear Enterprise...are an effective tool being used to raise the level of training. But it is not only necessary to move away from training that merely checks a box...down to an authoritative brain trust of just a few pertinent players (e.g. AFGSC/CC, HAF/A10 Director, AFNWC/CC, etc). As this study has portrayed

  12. A study on contaminant transport in indoor air

    International Nuclear Information System (INIS)

    Pujala, Usha; Sen, Soubhadra; Subramanian, V.; Srinivas, C.V.; Baskaran, R.; Venkatraman, B.

    2016-01-01

    In case of an accidental release of radioactive contaminant inside a well-ventilated room, the same will be transported to the different parts of the room due to the circulation of indoor air. To ensure safety of the operating personnel, it is important to identify the ideal locations for keeping the warning alarm systems. To address the problem, a detailed study is required where numerical simulation has to be supported by experimental verification. A computational methodology has already been verified for this purpose (IGC report-no.323). In this work, a study on the transport of an inert aerosol inside a well-ventilated isolated room has been carried out

  13. Indoor air quality study of forty east Tennessee homes

    Energy Technology Data Exchange (ETDEWEB)

    Hawthorne, A.R.; Gammage, R.B.; Dudney, C.S.; Hingerty, B.E.; Schuresko, D.D.; Parzyck, D.C.; Womack, D.R.; Morris, S.A.; Westley, R.R.; White, D.A.

    1984-12-01

    Over a one-year period, measurements of indoor air pollutants (CO/sub x/, NO/sub x/, formaldehyde, volatile organics, particulates, and radon) were made in 40 homes in East Tennessee. The houses were of various ages with different types of insulation and heating. Over one-half of the houses exceeded the ASHRAE indoor ceiling guideline of 0.1 ppM for formaldehyde on at least one occasion. Over the duration of the study, older houses averaged 0.04 ppM of formaldehyde while houses less than 5 years old averaged 0.08 ppM (P < 0.01). The highest concentration of formaldehyde measured was 0.4 ppM in a new home. Diurnal and seasonal fluctuations in levels of formaldehyde in some homes were as much as twofold and tenfold, respectively. The highest levels of formaldehyde were usually recorded during summer months. The concentration in indoor air of various organics was at least tenfold higher than in outdoor air. Carbon monoxide and nitrgen oxides were usually <2 and <0.02 ppM, respectively, except when gas stoves or kerosene space heaters were operating, or when a car was running in the garage. In 30% of the houses, the annual indoor guideline for radon, 4 pCi/L, was exceeded. The mean radon level in houses built on the ridgelines was 4.4 pCi/L, while houses located in the valleys had a mean level of 1.7 pCi/L (P < 0.01). The factor having the most impact on infiltration was operation of the central duct fan of the heating, ventilation, and air conditioning system. The mean rate of air exchange increased from 0.39 to 0.74 h/sup -1/ when the duct fan was operated (measurements prior to December 1982). This report presents the study design and implementation, describes the monitoring protocols, and provides a complete set of the data collected during the project. 25 references, 29 figures, 42 tables.

  14. STUDY ABOUT THE INCIDENCE OF HEARING-SPEAKING DISORDERS IN A POPULATION WITH MENTAL DEFICIENCY

    Directory of Open Access Journals (Sweden)

    Ioana Mihaela Tomulescu

    2003-01-01

    Full Text Available This study is about the incidence of hearing-speaking disorders in a population with mental deficiency. We studied 596 children interned in Neurology and Psychiatry Clinical Hospital of Oradea during the 1999 - 2001 period. In 596 children, 393 presented different types of mental deficiency. The most frequent disorders observed are hearing loss or deafness, deaf-mutism, mutism and speaking retardation. Also, we related an increased frequency in rural area and in group of children with severe mental deficiency.

  15. Experimental study on energy performance of clean air heat pump

    DEFF Research Database (Denmark)

    Fang, Lei; Nie, Jinzhe; Olesen, Bjarne W.

    2014-01-01

    An innovative clean air heat pump (CAHP) was designed and developed based on the air purification capacity of regenerative silica gel rotor. The clean air heat pump integrated air purification, dehumidification and cooling in one unit. A prototype of the clean air heat pump was developed...... to investigate its energy performance. Energy consumption of the prototype of CAHP was measured in laboratory at different climate conditions including mild-cold, mildhot and extremely hot and humid climates. The energy saving potential of the clean air heat pump compared to a conventional ventilation and air......-conditioning system was calculated. The experimental results showed that the clean air heat pump saved substantial amount of energy compared to the conventional system. For example, the CAHP can save up to 59% of electricity in Copenhagen, up to 40% of electricity in Milan and up to 30% of electricity in Colombo...

  16. Experimental study of photocatalytic concrete products for air purification

    Energy Technology Data Exchange (ETDEWEB)

    Huesken, G.; Hunger, M.; Brouwers, H.J.H. [Department of Civil Engineering, Faculty of Engineering Technology, University of Twente, P.O. Box 217, 7500 AE Enschede (Netherlands)

    2009-12-15

    Air quality in inner-city areas is a topic which receives much attention nowadays but in the coming years, the overall interest on this topic will become even bigger. One major concern is caused by the reduction of the limiting values given by the European Council Directive 1999/30/EC [Relating to limit values for sulphur dioxide, nitrogen dioxide and oxides of nitrogen, particulate matter and lead in ambient air. Official Journal of the European Communities 1999, L 163/41-60] and increasing traffic rates especially for diesel powered passenger cars and freight vehicles. A promising approach for solving the problem of nitrogen oxides (NO{sub x}) is the photochemical conversion of nitrogen oxides to low concentrated nitrates due to heterogeneous photocatalytic oxidation (PCO) using titanium dioxide (TiO{sub 2}) as photocatalyst. A variety of products containing TiO{sub 2} are already available on the European market and their working mechanism under laboratory conditions is proven. However, there is still a lack of transforming the experimental results obtained under laboratory conditions to practical applications considering real world conditions. This paper presents the research conducted on photocatalytic concrete products with respect to the evaluation of air-purifying properties. The degradation process of nitric oxide (NO) under laboratory conditions is studied using a test setup for measuring the performance of photocatalytic active concrete products. The test setup uses the UV-A induced degradation of NO and is oriented on the ISO standard ISO 22197-1:2007. Besides the introduction of the test setup, a uniform measuring procedure is presented to the reader which allows for an evaluation and direct comparison of the performance of photocatalytic active concrete products. This kind of direct comparison was not possible so far. Furthermore, the results of a comparative study on varying photocatalytic concrete products of the European market will be discussed

  17. Technology Solutions Case Study: Air Leakage and Air Transfer Between Garage and Living Space, Waldorf, Maryland

    Energy Technology Data Exchange (ETDEWEB)

    None

    2014-11-01

    In this project, Building Science Corporation worked with production homebuilder K. Hovnanian to evaluate air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multipoint fan pressurization tests and additional zone pressure diagnostic testing measured the garage and house air leakage, the garage-to-house air leakage, and garage and house pressure relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed. For houses employing whole-house supply ventilation (positive pressure) or balanced ventilation (same pressure effect as the baseline condition), adherence to the EPA Indoor airPLUS house-to-garage air sealing requirements should be sufficient to expect little to no garage-to-house air transfer.

  18. STUDY AND NUMERICAL SIMULATION OF SOLAR SYSTEM FOR AIR HEATING

    Directory of Open Access Journals (Sweden)

    M. Ghodbane

    2016-01-01

    Full Text Available The use of solar energy in sunny countries, is an effective outil for compensate the lack in the energy, their benefits are not related only to its economic benefits but especially for the environmental protection, so we must find solutions to the problems of pollution. This work is a theoretical study of a solar flat plate collector ; air is used as the heat transfer fluid. In this study, we established in first step the calculation of solar radiation in various sites in Algeria (Adrar, El Oued, Bechar, Biskra and Tamanrasset. The second step is the parameters influence study of the sites and climate on the performance of our collector. The results obtained are encouraging for the use of this type in the heating in the winter, also it can be used in different kinds of drying.

  19. Air Pollution in Shanghai Studied by Nuclear Analysis Techniques

    International Nuclear Information System (INIS)

    Zhang, G.; Tan, M.; Chen, J.; Jin, C.; Lin, J.; Li, X.; Li, Y.

    2009-01-01

    In this paper PIXE, μ-PIXE, XAFS, Moessbauer effect and radioisotope labelling method are briefly introduced. Those methods were used to study the pollution of atmospheric particulate matter (PM) in Shanghai. The speciation of Cr, Mn, Cu, and Zn in the PM10 and PM2.5 and different character of vehicle exhausted particles from other emission sources were studied. Source apportionment of the atmospheric lead was calculated with a combined method of lead isotope ratios and lead mass balance, along with μ-PIXE analysis of single particles and pattern recognition of the spectra. The fabricated ultrafine particles to simulate aerosol particle was used to study the translocation from alveolus into circulation across the air blood barrier

  20. Network-Centric Operations Case Study: Air-to-Air Combat With and Without Link 16

    National Research Council Canada - National Science Library

    Gonzales, Daniel; Hollywood, John; Kingston, Gina; Signori, David

    2005-01-01

    ...) Operational Special Project. In this exercise, the capabilities of F-15 air superiority aircraft equipped with voice-only communications were compared with F-15s equipped with voice and JTIDS Link 16 data link communications...

  1. Study on the air quality near vegetation along the highway

    International Nuclear Information System (INIS)

    Weijers, E.P.; Kos, G.P.A.; Van den Bulk, W.C.M.; Vermeulen, A.T.

    2007-08-01

    The results of downwind measurements of air quality around vegetation near a motorway are presented and discussed. The study (first ever in the Netherlands) was performed by order of the Innovation Programme Air Quality. At a carefully selected location measurements of PM and NOx were carried out downwind from a motorway in front of and (at various distances) behind a parallel orientated vegetation strip. Results are compared with synchronized data collected at a nearby location without vegetation (the 'reference' situation) and at the same distances from the motorway. Major findings are: Comparing measurements in front of and behind the vegetation strip show that the presence of vegetation tends to lower PM10 and PM2.5 concentrations immediately behind the vegetation. However, no such change is apparent in the concentrations of NO and NO2. The comparison with measurements executed without vegetation ('reference') indicate that concentration levels close to the vegetation strip are similar or somewhat higher. At a larger distance from motorway and vegetation (>30 m) NO and NO2 concentrations tend to be lower than what is observed in the reference situation. This could not be determined for PM [nl

  2. Kansas City Transportation and Local-Scale Air Quality Study (KC-TRAQS) Fact Sheet

    Science.gov (United States)

    In fall 2017, the U.S. Environmental Protection Agency (EPA) launched the Kansas City Transportation Local-Scale Air Quality Study (KC-TRAQS) to learn more about local community air quality in three neighborhoods in Kansas City, KS.

  3. Indoor air quality study of forty east Tennessee homes

    International Nuclear Information System (INIS)

    Hawthorne, A.R.; Gammage, R.B.; Dudney, C.S.

    1984-12-01

    Over a one-year period, measurements of indoor air pollutants (CO/sub x/, NO/sub x/, formaldehyde, volatile organics, particulates, and radon) were made in 40 homes in East Tennessee. The houses were of various ages with different types of insulation and heating. Over one-half of the houses exceeded the ASHRAE indoor ceiling guideline of 0.1 ppM for formaldehyde on at least one occasion. Over the duration of the study, older houses averaged 0.04 ppM of formaldehyde while houses less than 5 years old averaged 0.08 ppM (P -1 when the duct fan was operated (measurements prior to December 1982). This report presents the study design and implementation, describes the monitoring protocols, and provides a complete set of the data collected during the project. 25 references, 29 figures, 42 tables

  4. Feasibility study on novel room air conditioner with natural cooling capability

    International Nuclear Information System (INIS)

    Han, Zongwei; Liu, Qiankun; Zhang, Yanqing; Zhang, Shuwei; Liu, Jiangzhen; Li, Weiliang

    2016-01-01

    Highlights: • A novel heat pipe combined evaporative cooling room air conditioner is constructed. • The mathematical model of the air conditioner is established. • The reliability of the model is verified by experiments. • The performance of the novel and conventional air conditioner is compared. • The applicability of the novel air conditioner in different areas is investigated. - Abstract: In order to improve the energy efficiency of room air conditioners, this paper proposed a new air conditioner that combined evaporative cooling technology, separate type heat pipe technology, and vapour compression refrigeration technology (called “combined air conditioner”). The mathematical model of the air conditioner was established and its reliability was verified by experiments. Based on the model, the simulation of the operating performance of the combined air conditioner and a conventional air conditioner was studied in typical climate regions during the cooling period, with the following results: In cold and dry areas like Shenyang, compared with the conventional air conditioner, the average cooling coefficient of performance (COP) of the combined air conditioner was increased by 27.40%. As the climate gradually became warmer and humidity gradually increased, the running time of the heat pipe cooling mode was gradually reduced, and then the energy-saving effect of the combined air conditioner became worse. For example, in the hot and humid Guangzhou, the energy saving rate was only 11.81%. Therefore, it was found that the combined air conditioner had good energy-saving potential in cold and dry areas.

  5. Globalisation and Air Transportation Industry: A Case Study of Malaysia

    OpenAIRE

    Kamaruddin, Shahrul Kamal

    2010-01-01

    Air transportation remains a large and growing industry that is central to the globalisation process. The globalisation impact on the air transportation industry remains largely focused on the airlines, while the impact on airports is rarely defined. The objective of this research is to identify the processes of globalisation that impact the air transportation industry specifically on airport development and operations that will greatly influence the changing nature of airports. A survey ques...

  6. Study of air ingress accident of an HTGR

    International Nuclear Information System (INIS)

    Hishida, Makoto

    1995-01-01

    Inherent properties of high temperature gas cooled reactors (HTGR) facilitate the design of HTGRs with high degree of passive safety performances. In this context, it is very important to establish a design criteria for a passive safe function for the air ingress accident. However, it is absolutely necessary to investigate the air ingress behavior during the accident before exploring the design criteria. The present paper briefly describes major activities and results of the air ingress research in our laboratory. (author)

  7. A Study on health damage due to air pollution

    Energy Technology Data Exchange (ETDEWEB)

    Han, Hwa Jin; Oh, So Young [Korea Environment Institute, Seoul (Korea)

    1998-12-01

    According to the domestic and foreign change in given conditions of air preservation policy, the air preservation policy in Korea should be implemented scientifically and reasonably. A gradual turnover to receptor-oriented reflecting human health and ecological effect is needed to establish and promote the air preservation policy systemically and in a long-term basis. Based on the quantified health damage of a people, air preservation policy in Korea should develop as a management policy to develop and implement an optimum management mechanism to minimized health damage of receptor. 19 refs., 2 figs., 25 tabs.

  8. Study of air purification in the production of radioactive compounds

    International Nuclear Information System (INIS)

    Fradin, J.; Desroches, J.

    1958-12-01

    As the fabrication of radio-elements takes place in almost airtight enclosures in which a frequent air renewal is required, and while taking the purification rate into account (1.000 to 5.000 m 3 /h), the authors report the study of wet purification in conjunction with dry purification through paper filters, in order to capture dusts. An apparatus has been implemented which allows high gas flow rates. A radioactive aerosol has been introduced in this apparatus and its efficiency has been measured by different means. The authors describe the instrumentation (column, aerosol generator), operation, rate adjustment, and losses. Aerosols of manganese and sodium have been used. Their particle granulometry has been determined. The authors report several types of tests [fr

  9. Study of air pollution in Chile using biomonitors

    International Nuclear Information System (INIS)

    Cortes, Eduardo; Gras, Nuri; Andonie, Oscar; Sepulveda, Susana; Pereira, Iris

    2001-01-01

    A project has been undertaken within the framework of a Co-ordinated Research Programme (CRP) supported by the International Atomic Energy Agency (IAEA) to carry out a long term study on atmospheric air pollution in Chile using biomonitors. The present paper describes the activities undertaken within the framework of this project. Sampling of different lichens species has been performed in clean areas (native forest), preparation of such samples has been done under controlled, cryogenic conditions and analysed by neutron activation analysis. Participation in an intercomparison run organized by the IAEA for the determination of trace and minor elements in two lichens samples, has also been carried out. Transplant of lichens collected in clean areas has been done in Santiago. (author)

  10. People maintain their sun exposure behaviour in a 5-7-year follow-up study using personal electronic UVR dosimeters

    DEFF Research Database (Denmark)

    Thieden, Elisabeth; Heydenreich, Jakob; Philipsen, Peter A

    2013-01-01

    The main purpose of this study was to investigate whether people change their sun behaviour over a period of 7 years. Thus 32 volunteers, who had all participated in earlier sun exposure studies in 1999-2001, were enrolled in a follow-up study in 2006. They were selected to represent a previous low......, medium and high UVR exposure. They participated for mean 121 days (range 65-157 days) wearing a personal, electronic wrist-borne UVR dosimeter and completed sun exposure diaries. No statistically significant differences were seen from year to year in the estimated annual UVR dose, mean UVR dose per day...... they received a mean for the previous participation years (1999-2001) of 236 SED (median 153 SED, range 24-980 SED). The estimated annual UVR dose for each of the previous sun years and the estimated annual dose for 2006 correlated significantly (R(2) = 0.51; p...

  11. Study of Air Quality Health Index and its Application in Seven Cities of Iran in 2011

    Directory of Open Access Journals (Sweden)

    Majid Kermani

    2017-03-01

    Full Text Available Abstract Background: Poor air quality has a lot of damage on the environment and humans. Awareness of the air quality situation reduces health effects of air pollution. This study was performed with the aim of the comparative investigation of Air Quality Health Index (AQHI and its application in seven major cities of Iran in 2011. Materials and Methods: This study was a descriptive–analytic one. First, the required data of four criteria pollutants were taken from Department of Environment in seven major cities of Iran. The data were validated by the World Health Organization criteria. The air quality health index was measured based on the instructions and classified into low, medium, high and very high degrees according to the air quality standard tables. Results: The results demonstrate that according to air quality health index, the level of air pollution in seven major cities of Iran has been undesirable and air quality has exceeded the standard level in Ahvaz 85%, Arak73%, Tehran70%, Esfahan60%, Shiraz 47%, Tabriz 43% and, Mashhad 29% of days. Conclusion: Due to poor air quality and health consequences resulting from it, importance of Air Quality Health Index is explored in planning to control and reduce air pollution and awareness of peoples from daily status of air quality and its health effects.

  12. Performance Study of Solar Air Heater Having Absorber Plate with Half-Perforated Baffles

    OpenAIRE

    Maheshwari, B. K.; Karwa, Rajendra; Gharai, S. K.

    2011-01-01

    The paper presents a detailed mathematical model for performance prediction of a smooth duct solar air heater validated against the experimental results. Experimental study on a solar air heater having absorber plate with half-perforated baffles on the air flow side shows thermal efficiency enhancement of 28%–45% over that of the smooth duct solar air heater, which is attributed to the heat transfer enhancement (of the order of 180%–235%) due to the perforated baffles attached to the absorber...

  13. [Study on the groundwater petroleum contaminant remediation by air sparging].

    Science.gov (United States)

    Wang, Zhi-Qiang; Wu, Qiang; Zou, Zu-Guang; Chen, Hong; Yang, Xun-Chang; Zhao, Ji-Chu

    2007-04-01

    The groundwater petroleum contaminant remediation effect by air sparging was investigated in an oil field. The results show that the soil geological situation has great influence on the air distribution, and the shape of air distribution is not symmetrical to the air sparging (AS) well as axis. The influence distance in the left of AS well is 6 m, and only 4 m in the right. The petroleum removal rate can reach 70% in the zone with higher air saturation, but only 40% in the zone with lower air saturation, and the average petroleum removal rate reaches 60% in the influence zone for 40 days continuous air sparging. The petroleum components in groundwater were analyzed by GC/MS (gas chromatogram-mass spectrograph) before and after experiments, respectively. The results show that the petroleum removal rate has relationship with the components and their properties. The petroleum components with higher volatility are easily removed by volatilization, but those with lower volatility are difficult to remove, so a tailing effect of lingering residual contaminant exists when the air sparging technology is adopted to treat groundwater contaminated by petroleum products.

  14. Health effects from indoor air pollution: case studies.

    Science.gov (United States)

    White, L E; Clarkson, J R; Chang, S N

    1987-01-01

    In recent years there has been a growing awareness of the health effects associated with the presence of contaminants in indoor air. Numerous agents can accumulate in public buildings, homes and automobiles as a result of ongoing activities that normally occur in these closed spaces. Ventilation is a major factor in the control of indoor air pollutants since proper movement of air can prevent or minimize the build up of compounds in buildings. The recent emphasis on energy conservation has lead to measures which economize on energy for heating and air conditioning, but which also trap pollutants within a building. Three cases of indoor air pollution were investigated. A typical investigation of indoor air pollutant problems includes the following: interviews with building occupants; history of the building with regard to maintenance, pesticide treatment, etc.; a survey of the building and ventilation; and when warranted, sampling and analysis of air. Each case presented is unique in that atypical situations caused agents to accumulate in a building or section of a building. The indoor air problems in these cases were solved by identifying and removing the source of the offending agent and/or improving the ventilation in the building.

  15. Experimental study of air evaporative cooling process using microporous membranes

    Directory of Open Access Journals (Sweden)

    Englart Sebastian

    2017-01-01

    Full Text Available This article describes the potential use of microporous membranes in evaporative cooling applications for air conditioning. The structure of membrane contractor and the measuring device are described. On the basis of the results of the measurements air cooling effectiveness coefficient has been determined.

  16. An indoor air filtration study in homes of elderly

    DEFF Research Database (Denmark)

    Karottki, Dorina Gabriela; Spilak, Michal; Frederiksen, Marie

    2013-01-01

    Exposure to particulate air pollution increases respiratory and cardiovascular morbidity and mortality, especially in elderly, possibly through inflammation and vascular dysfunction.......Exposure to particulate air pollution increases respiratory and cardiovascular morbidity and mortality, especially in elderly, possibly through inflammation and vascular dysfunction....

  17. Vegetation studies on Vandenberg Air Force Base, California

    Science.gov (United States)

    Schmalzer, Paul A.; Hickson, Diana E.; Hinkle, C. Ross

    1988-01-01

    Vandenburg Air Force Base, located in coastal central California with an area of 98,400 ac, contains resources of considerable biological significance. Available information on the vegetation and flora of Vandenburg is summarized and new data collected in this project are presented. A bibliography of 621 references dealing with vegetation and related topics related to Vanderburg was compiled from computer and manual literature searches and a review of past studies of the base. A preliminary floristic list of 642 taxa representing 311 genera and 80 families was compiled from past studies and plants identified in the vegetation sampling conducted in this project. Fifty-two special interest plant species are known to occur or were suggested to occur. Vegetation was sampled using permanent plots and transects in all major plant communities including chaparral, Bishop pine forest, tanbark oak forest, annual grassland, oak woodland, coastal sage scrub, purple sage scrub, coastal dune scrub, coastal dunes, box elder riparian woodland, will riparian woodland, freshwater marsh, salt marsh, and seasonal wetlands. Comparison of the new vegetation data to the compostie San Diego State University data does not indicate major changes in most communities since the original study. Recommendations are made for additional studies needed to maintain and extend the environmental data base and for management actions to improve resource protection.

  18. Study of air pollution in Buenos Aires city using neutron activation analysis and x-ray fluorescence

    International Nuclear Information System (INIS)

    Pla, R.R.; Tafuri, V.; Custo, G.S.

    1994-01-01

    Buenos Aires city and its surroundings, has a huge population and very dense traffic. There are many possible pollution sources that can be identified, but other characteristics such as weather and location counteract some of these sources to the benefit of the atmosphere of the city. Although several groups have been working on these subjects, there is not enough information about which elements are present in Buenos Aires air. The aim of this project is to provide information about the elemental profile of the atmosphere of the city and to evaluate and to make an interpretation of the obtained data. Both XRF and INAA are going to be used for analyzing the air filter samples with the participation of the Meteorological Service in sampling and interpretation of the results. By choosing adequate sampling sites and times, differences between day/night, week day/weekend will be looked for. The influence of non-leaded petrols will be studied. Some work on air samples was done before the beginning of this contract to settle future working conditions. Some results from this study are presented only as preliminary ones. Sampling will begin during this April at two sites with different traffic density. For both XRF and NAA suitable standards will be prepared. Medium and long lived nuclides are going to be analyzed by INAA. Plans for 1993 are given as well as possible collaboration with other groups in the country. (author). 3 refs, 1 tab

  19. VENOUS AIR-EMBOLISM, PRESERVATION REPERFUSION INJURY, AND THE PRESENCE OF INTRAVASCULAR AIR COLLECTIONS IN HUMAN DONOR LIVERS - A RETROSPECTIVE CLINICAL-STUDY

    NARCIS (Netherlands)

    WOLF, RFE; SLUITER, WJ; BALLAST, A; VANDAM, RM; SLOOFF, MJH

    In human liver transplantation, air embolism is seldom encountered after graft reperfusion. Nevertheless, despite adequate flushing and clamping routines, air emboli have been reported in transesophageal echocardiography (TEE) studies performed during the reperfusion phase, We retrospectively

  20. Air pollution and health in Sri Lanka: a review of epidemiologic studies

    Directory of Open Access Journals (Sweden)

    Sathiakumar Nalini

    2010-06-01

    Full Text Available Abstract Background Air pollution is increasingly documented as a threat to public health in most developing countries. Evaluation of current air quality levels, regulatory standards and scientific literature on outdoor and indoor air pollution, and health effects are important to identify the burden, develop and implement interventions and to fill knowledge gaps in Sri Lanka. Methods PUBMED and Medline databases, local journals and conference proceedings were searched for epidemiologic studies pertaining to air pollution and health effects in Sri Lanka. All the studies pertaining to air pollution and health effects were considered. Results Sixteen studies investigated the association between exposure to ambient or indoor air pollution (IAP and various health outcomes ranging from respiratory symptoms, low birth weight and lung cancers. Of the sixteen, three used a case control design. Half of the studies collected exposure data only through questionnaires. There were positive associations between air pollution and adverse health effects in all studies. Methodological limitations in most of the studies resulted in poor quantification of risk estimates. Conclusion A limited number of epidemiological studies in Sri Lanka have investigated the health effects of air pollution. Based on findings of studies and reported air quality levels, air pollution may be considered a neglected public health problem in Sri Lanka.

  1. Air pollution and health in Sri Lanka: a review of epidemiologic studies.

    Science.gov (United States)

    Nandasena, Yatagama Lokuge S; Wickremasinghe, Ananda R; Sathiakumar, Nalini

    2010-06-02

    Air pollution is increasingly documented as a threat to public health in most developing countries. Evaluation of current air quality levels, regulatory standards and scientific literature on outdoor and indoor air pollution, and health effects are important to identify the burden, develop and implement interventions and to fill knowledge gaps in Sri Lanka. PUBMED and Medline databases, local journals and conference proceedings were searched for epidemiologic studies pertaining to air pollution and health effects in Sri Lanka. All the studies pertaining to air pollution and health effects were considered. Sixteen studies investigated the association between exposure to ambient or indoor air pollution (IAP) and various health outcomes ranging from respiratory symptoms, low birth weight and lung cancers. Of the sixteen, three used a case control design. Half of the studies collected exposure data only through questionnaires. There were positive associations between air pollution and adverse health effects in all studies. Methodological limitations in most of the studies resulted in poor quantification of risk estimates. A limited number of epidemiological studies in Sri Lanka have investigated the health effects of air pollution. Based on findings of studies and reported air quality levels, air pollution may be considered a neglected public health problem in Sri Lanka.

  2. Training Studies with Compressed Air Breathing Apparatus – Methodology, Exercises

    Directory of Open Access Journals (Sweden)

    Buks Roberts

    2015-11-01

    Full Text Available The current article describes topics ranging from the respiratory physiology and the structure of compressed air breathing apparatus to the performance of practical training exercises in an unbreathable environment (hereinafter referred to as UE.

  3. CFD study on the effects of boundary conditions on air flow through an air-cooled condenser

    Science.gov (United States)

    Sumara, Zdeněk; Šochman, Michal

    2018-06-01

    This study focuses on the effects of boundary conditions on effectiveness of an air-cooled condenser (ACC). Heat duty of ACC is very often calculated for ideal uniform velocity field which does not correspond to reality. Therefore, this study studies the effect of wind and different landscapes on air flow through ACC. For this study software OpenFOAM was used and the flow was simulated with the use of RANS equations. For verification of numerical setup a model of one ACC cell with dimensions of platform 1.5×1.5 [m] was used. In this experiment static pressures behind fan and air flows through a model of surface of condenser for different rpm of fan were measured. In OpenFOAM software a virtual clone of this experiment was built and different meshes, turbulent models and numerical schemes were tested. After tuning up numerical setup virtual model of real ACC system was built. Influence of wind, landscape and height of ACC on air flow through ACC has been investigated.

  4. Sitewide feasibility study Eielson Air Force Base, Alaska

    Energy Technology Data Exchange (ETDEWEB)

    Last, G.V.; Lanigan, D.C.; Josephson, G.B.; Bagaasen, L.M.

    1995-09-01

    The Sitewide Feasibility Study (FS) is required under the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA), the National Contingency Plan (NCP), and the Federal Facility Agreement (FFA) for Eielson Air Force Base (AFB). It is based on findings presented in the Sitewide Remedial Investigation (RI) Report (USAF 1995a), and the Sitewide Baseline Risk Assessment (BLRA) Report (USAF 1995b). Under the FFA, 64 potential source areas were placed in one of six operable units, based on similar contaminant and environmental characteristics, or were included for evaluation under a Source Evaluation Report (SER). The sitewide RI was directed at contamination that was not confined to an operable unit (OU) or SER source area. The objectives of the sitewide RI were to: Provide information about site characteristics to support individual OU RI/FS efforts and the sitewide RI/FS, including site hydrogeology and determination of background soil and groundwater characteristics; identify and characterize contamination that is not confined or attributable to a specific source area through sitewide monitoring of groundwater and surface water; evaluate cumulative risks to human health and the environment from contamination on a sitewide basis; and provide a mechanism for continued cohesive sitewide monitoring.

  5. Effect of air humidification on the sick building syndrome and perceived indoor air quality in hospitals: a four month longitudinal study.

    Science.gov (United States)

    Nordström, K; Norbäck, D; Akselsson, R

    1994-01-01

    The sensation of dryness and irritation is essential in the sick building syndrome (SBS), and such symptoms are common in both office and hospital employees. In Scandinavia, the indoor relative humidity in well ventilated buildings is usually in the range 10-35% in winter. The aim of this study was to evaluate the effect of steam air humidification on SBS and perceived air quality during the heating season. The study base consisted of a dynamic population of 104 hospital employees, working in four new and well ventilated geriatric hospital units in southern Sweden. Air humidification raised the relative air humidity to 40-45% in two units during a four months period, whereas the other two units served as controls with relative humidity from 25-35%. Symptoms and perceived indoor air quality were measured before and after the study period by a standardised self administered questionnaire. The technical measurements comprised room temperature, air humidity, static electricity, exhaust air flow, aerosols, microorganisms, and volatile organic compounds in the air. The most pronounced effect of the humidification was a significant decrease of the sensation of air dryness, static electricity, and airway symptoms. After four months of air humidification during the heating season, 24% reported a weekly sensation of dryness in humidified units, compared with 73% in controls. No significant changes in symptoms of SBS or perceived air quality over time were found in the control group. The room temperature in all units was between 21-23 degrees C, and no significant effect of air humidification on the air concentration of aerosols or volatile organic compounds was found. No growth of microorganisms was found in the supply air ducts, and no legionella bacteria were found in the supply water of the humidifier. Air humidification, however, significantly reduced the measured personal exposure to static electricity. It is concluded that air humidification during the heating season

  6. A Comparison of Exposure Metrics for Traffic-Related Air Pollutants: Application to Epidemiology Studies in Detroit, Michigan

    Science.gov (United States)

    Vehicles are major sources of air pollutant emissions, and individuals living near large roads endure high exposures and health risks associated with traffic-related air pollutants. Air pollution epidemiology, health risk, environmental justice, and transportation planning studi...

  7. A Longitudinal Study of Myers-Briggs Personality Types in Air Traffic Controllers

    National Research Council Canada - National Science Library

    Dollar, Carolyn S; Schroeder, David J

    2004-01-01

    .... The study investigated the relationship between MBTI types and initial success in the Air Traffic Control Academy Screen Program, subsequent field training outcomes, and transition to a supervisory...

  8. A Study on Public Opinion Poll and Policy on Indoor Air Pollution

    Energy Technology Data Exchange (ETDEWEB)

    Kim, K.S.; Lee, H.S.; Kong, S.Y.; Ku, H.J. [Korea Environment Institute, Seoul (Korea)

    2001-12-01

    The purpose of this study is to review previous studies on indoor air pollution and to propose national strategies and policy measures for protecting public health from indoor air pollution based on the results of public survey research. Indoor air has the potential to be polluted by hazardous materials that might lead to serious health problems. It is well known that the indoor spaces are more polluted than outdoor ones, which can be a major health problem for those that live in urban areas who spend most of their time indoors. In Korea, studies on indoor air pollution are usually conducted under the auspices of academic research, which only focus on particular types of indoor spaces and certain concepts of indoor air quality. Thus, at present, the studies on the policies or policy measures concerning indoor air quality management are difficult to find in the country. The governmental agencies that are presently involved in the management of indoor air quality include: the Ministry of Health and Welfare, Ministry of Construction and Transportation, Ministry of Education and Human Resources Development, and Ministry of Environment. However, due to differing regulatory standards between the concerned agencies, the national management of indoor air quality has so far proven to be ineffective. Although the Ministry of Environment recently proposed a law to manage indoor air quality, it is only focuses on managing particular types of indoor spaces not regulated by other governmental bodies and is not effective in the effort towards a national managing system for indoor air pollution. According to a survey conducted by the Korea Environment Institute (KEI), the residents of the Seoul metropolitan area have been felt that environmental pollution negatively affects their health, and especially consider outdoor air pollution to be the most harmful type of pollution. Although these urban residents spend more than 20 hours a day indoors, the survey shows that they do not

  9. An experimental study of thermal comfort at different combinations of air and mean radiant temperature

    DEFF Research Database (Denmark)

    Simone, Angela; Olesen, Bjarne W.

    2009-01-01

    It is often discussed if a person prefers a low air temperature (ta) and a high mean radiant temperature (tr), vice-versa or it does not matter as long as the operative temperature is acceptable. One of the hypotheses is that it does not matter for thermal comfort but for perceived air quality......, a lower air temperature is preferred. This paper presents an experimental study with 30 human subjects exposed to three different combinations of air- and mean radiant temperature with an operative temperature around 23 °C. The subjects gave subjective evaluations of thermal comfort and perceived air...... quality during the experiments. The PMV-index gave a good estimation of thermal sensation vote (TSV) when the air and mean radiant temperature were the same. In the environment with different air- and mean radiant temperatures, a thermal comfort evaluation shows an error up to 1 scale unit on the 7-point...

  10. Study of air pollution scavenging. Fifteenth progress report. [Air pollution over St. Louis, Missouri and rural Illinois

    Energy Technology Data Exchange (ETDEWEB)

    Semonin, R.G.; Ackerman, B.; Gatz, D.F.; Rilberg, S.D.; Peden, M.E.; Stahlhut, R.K.; Stensland, G.J.

    1977-07-01

    Selected analyses of air and rainwater chemistry and meteorological data are presented as part of the final efforts on the 5-year METROMEX study. The size characterization, air concentration, and source identification of aerosols over and near St. Louis are related to the urban-industrial activities of the metropolitan area. The precipitation studies are comprised of a comparison of chemical analyses of simulated rain samples between several laboratories, including the Survey. The results showed that the analytical technique used by the Survey for the chemical analysis of the METROMEX samples is excellent for increasing confidence in the published data. Other precipitation analyses are directed toward the acid rain problem as demonstrated by historical and current measurements in Illinois. The meteorological investigations consist of analysis of diurnal temperature and moisture cycles at urban and rural sites which relates to the development of the planetary boundary layer (PBL) as perturbed by the city. The three-dimensional character of the PBL is also presented as determined by the radiosonde operations during METROMEX. Finally, the technique to calculate three-dimensional trajectories of air motion using the numerous pilot balloon observations acquired during the project is presented. These data are essential for the full interpretation of the air and rain chemistry observations, and the development of empirical models of pollutant scavenging.

  11. Scattering study at free air ionization chamber diaphragm

    International Nuclear Information System (INIS)

    Santos, Alexandre Lo Bianco dos

    2011-01-01

    The maim of this work consisted in the assessment of the correction factor for air kerma, due to scattered radiation in the diaphragm of the free-air ionization chamber model 481. LNMRl measurements were made to acquire x-ray spectra corresponding to the Qualities RQR-M, described in IEC 61627 standards (2005). These spectra were used as input data in the MC simulations. The operational range of energy spectra provide up to 35 keV. This energy range is typically used in diagnostic radiology, although there is not primary standard for air kerma. The determination of this factor is a fundamental process in the primary standardization of the air kerma. These factors were obtained by computer simulation using the Penelope code. The results are k RQR-M1 =0,9946, k RQR -M2 =0,9932, k RQR-M3 =0,9978 and k RQR-M4 =0,9885; with uncertainties of 0,007 and coverage factor equal to 2. lt can be concluded that, with respect to the diaphragm, the chamber can be used in the primary standard of air kerma. (author)

  12. Statistical Methodological Issues in Studies of Air Pollution and Respiratory Disease.

    OpenAIRE

    Hyndman, R.J.; Erbas, B.

    2001-01-01

    Epidemiological studies have consistently shown short term associations between levels of air pollution and respiratory disease in countries of diverse populations, geographical locations and varying levels of air pollution and climate. The aims of this paper are: (1) to assess the sensitivity of the observed pollution effects to model specification, with particular emphasis on the inclusion of seasonally adjusted covariates; and (2) to study the effect of air pollution on respiratory disease...

  13. Pilot study on indoor air quality: Managing indoor air-quality risks. Report on a meeting held in St. Michaels, Maryland on October 25-27, 1989

    International Nuclear Information System (INIS)

    1990-06-01

    Included in this study are the following: quantifying future trends of indoor air quality as a basis for government policy plans; assessing indoor air quality risks of pesticides; formaldehyde emission standards in the Federal Republic of Germany; orientations and actions of the European Community in the assessment and prevention of indoor air pollution; EPA and indoor air quality; the non-regulatory approach to reducing risks from radon exposure; U.S. consumer product safety commission; a builders guide to healthy homes; WHO air quality guidelines for Europe; the approach to control indoor air quality in Italy; guidelines - ventilation classes; energy consequences of upgrading indoor air quality; Canada's guidelines for residential indoor air quality: rationale and scope; Canadian ventilation and venting standards; indoor air quality building surveys case studies; design of indoor air quality studies; summary findings of inter-ministerial committee on indoor air quality (Ontario); the Quebec approach; employee survey EPA headquarters; pollution in closed spaces and its consequences in conservation of works of art; and how Norwegian health authorities will handle indoor air quality problems

  14. Study of 222Rn variations in the soil air

    International Nuclear Information System (INIS)

    Holy, K.; Boehm, R.; Matos, M.; Polaskova, A.; Hola, O.

    1998-01-01

    A significant source of radon in the indoor atmosphere is represented by 222 Rn in the soil air, ie., by the fraction of radon atoms produced by alpha decay of 226 Ra in soil grains that escaped into soil pores. In the paper the results are presented of a three year monitoring of radon in soil air, using a 125 ml Lucas type scintillation cell. Radon concentration depth profiles in the soil in various seasons of the year were also measured, and saturated concentration of radon in soil air was found at a depth of about 2 m. Monthly variations in the radon concentration were observed over several months and the possible causes of the variations are discussed. Daily courses of radon concentration were also measured and the results are presented. (A.K.)

  15. Studies of air plasma techniques in mutating Penicillium chrysogenum

    International Nuclear Information System (INIS)

    Gui Fang; Liu Hui; Wang Hui; Wang Peng; Yuan Chengling; Zheng Zhiming

    2011-01-01

    penicillin producing strain Penicillium chrysogenum Pc05 as the starting strain was mutated by low-temperature air plasma technology. As the result revealed, in 30 minutes, the survival rate of spores followed the saddle-shaped curve. The positive mutants accounted for 44.19% of all mutants while the negative mutation was low. After primary and secondary screening, the mutant aPc051310 was obtained, and eventually its penicillin titer increased 42.1% compared with that of starting strain. Synergetic effect between chemical reactive species and charged particles was considered as the main mutation mechanism involved in low temperature air plasma. All the results have been proved that as a new industrial microbial strains mutation method, low temperature air plasma has potential applications. (authors)

  16. An indoor air quality study of 40 East Tennessee homes

    International Nuclear Information System (INIS)

    Hawthorne, A.R.; Gammage, R.B.; Dudney, C.S.

    1986-01-01

    Over a 1-yr period, measurements of indoor air pollutants (COsub(x), NOsub(x), formaldehyde, volatile organics, particulate matter, and radon) were made in 40 homes in east Tennessee. The houses were of various ages with different types of insulation and heating. In 30% of the houses, the radon concentration exceeded 4 pCi/L. The mean radon level in houses built near ridgelines was 4.4 pCi/L, while houses located in the valleys had a mean level of 1.7 pCi/L. The factor having the most impact on infiltration was operation of the central duct fan of the heating, ventilation, and air conditioning system. For measurements made before December 1984, the mean rate of air exchange increased from 0.39 to 0.74 h -1 when the duct fan was operated. (author)

  17. Using GIS to study the health impact of air emissions.

    Science.gov (United States)

    Dent, A L; Fowler, D A; Kaplan, B M; Zarus, G M; Henriques, W D

    2000-02-01

    Geographical Information Systems (GIS) is a fast-developing technology with an ever-increasing number of applications. Air dispersion modeling is a well-established discipline that can produce results in a spatial context. The marriage of these two applications is optimal because it leverages the predictive capacity of modeling with the data management, analysis, and display capabilities of GIS. In the public health arena, exposure estimation techniques are invaluable. The utilization of air emission data, such as U.S. EPA Toxic Release Inventory (TRI) data, and air dispersion modeling with GIS enable public health professionals to identify and define the potentially exposed population, estimate the health risk burden of that population, and determine correlations between point-based health outcome results with estimated health risk.

  18. WIPP air-intake shaft disturbed-rock zone study

    International Nuclear Information System (INIS)

    Dale, T.; Hurtado, L.D.

    1996-01-01

    The disturbed-rock zone surrounding the air-intake shaft at the Waste Isolation Pilot Plant (WIPP) site was investigated to determine the extent and the permeability of the disturbed-rock zone as a function of radial distance from the 6.1 m diameter shaft, at different elevations within the Salado. Gas- and brine-permeability tests were performed in the bedded halite of the Salado formation at two levels within the air-intake shaft. The gas- and brine-permeability test results demonstrated that the radial distance to an undisturbed formation permeability of 1 x 10 -21 m 2 was less than 3.0 m

  19. Multisite study of particle number concentrations in urban air.

    Science.gov (United States)

    Harrison, Roy M; Jones, Alan M

    2005-08-15

    Particle number concentration data are reported from a total of eight urban site locations in the United Kingdom. Of these, six are central urban background sites, while one is an urban street canyon (Marylebone Road) and another is influenced by both a motorway and a steelworks (Port Talbot). The concentrations are generally of a similar order to those reported in the literature, although higher than those in some of the other studies. Highest concentrations are at the Marylebone Road site and lowest are at the Port Talbot site. The central urban background locations lie somewhere between with concentrations typically around 20 000 cm(-3). A seasonal pattern affects all sites, with highest concentrations in the winter months and lowest concentrations in the summer. Data from all sites show a diurnal variation with a morning rush hour peak typical of an anthropogenic pollutant. When the dilution effects of windspeed are accounted for, the data show little directionality at the central urban background sites indicating the influence of sources from all directions as might be expected if the major source were road traffic. At the London Marylebone Road site there is high directionality driven by the air circulation in the street canyon, and at the Port Talbot site different diurnal patterns are seen for particle number count and PM10 influenced by emissions from road traffic (particle number count) and the steelworks (PM10) and local meteorological factors. Hourly particle number concentrations are generally only weakly correlated to NO(x) and PM10, with the former showing a slightly closer relationship. Correlations between daily average particle number count and PM10 were also weak. Episodes of high PM10 concentration in summer typically show low particle number concentrations consistent with transport of accumulation mode secondary aerosol, while winter episodes are frequently associated with high PM10 and particle number count arising from poor dispersion of

  20. Winter season air pollution in El Paso-Ciudad Juarez. A review of air pollution studies in an international airshed

    Energy Technology Data Exchange (ETDEWEB)

    Einfeld, W.; Church, H.W.

    1995-03-01

    This report summarizes a number of research efforts completed over the past 20 years in the El Paso del Norte region to characterize pollution sources and air quality trends. The El Paso del Norte region encompasses the cities of El Paso, Texas and Ciudad Juarez, Chihuahua and is representative of many US-Mexico border communities that are facing important air quality issues as population growth and industrialization of Mexican border communities continue. Special attention is given to a group of studies carried out under special US Congressional funding and administered by the US Environmental Protection Agency. Many of these studies were fielded within the last several years to develop a better understanding of air pollution sources and trends in this typical border community. Summary findings from a wide range of studies dealing with such issues as the temporal and spatial distribution of pollutants and pollution potential from both stationary and mobile sources in both cities are presented. Particular emphasis is given to a recent study in El Paso-Ciudad Juarez that focussed on winter season PM{sub 10} pollution in El Paso-Ciudad Juarez. Preliminary estimates from this short-term study reveal that biomass combustion products and crustal material are significant components of winter season PM{sub 10} in this international border community.

  1. Molecular epidemiology studies of the effects of air polution

    Czech Academy of Sciences Publication Activity Database

    Šrám, Radim; Binková, Blanka; Dejmek, Jan; Chvátalová, Irena; Machala, M.; Solanský, I.

    2002-01-01

    Roč. 13, č. 4 (2002), s. 93 ISSN 1044-3983. [Conference of the ISEA /12./, Conference of the ISEE /14./. 11.08.2002-15.08.2002, Vancouver - Canada] R&D Projects: GA MŽP SI/340/2/00 Keywords : air pollution Subject RIV: DN - Health Impact of the Environment Quality

  2. A Study of the Effects of Air Pollution on Children

    Science.gov (United States)

    Bury, Irene B.

    1970-01-01

    An investigation of the possible effects of air pollution on the absenteeism of elementary school children showed that a greater percent of absences occurred in the test group than in a comparable group. There is little question as to the importance that such information should have for educators, informed parents, and other adults in community…

  3. Electric air filtration: theory, laboratory studies, hardware development, and field evaluations

    International Nuclear Information System (INIS)

    Bergman, W.; Biermann, A.; Kuhl, W.

    1983-09-01

    We summarize the results of a seven-year research project for the US Department of Energy (DOE) to develop electric air filters that extend the service life of high-efficiency particulate air (HEPA) filters used in the nuclear industry. This project was unique to Lawrence Livermore National Laboratory (LLNL), and it entailed comprehensive theory, laboratory studies, and hardware development. We present our work in three major areas: (1) theory of and instrumentation for filter test methods, (2) theoretical and laboratory studies of electric air filters, and (3) development and evaluation of eight experimental electric air filters

  4. Real scale experimental study for performance evaluation of unidirectional air diffuser perforated panels

    Science.gov (United States)

    Tăcutu, Laurenţiu; Nastase, Ilinca; Iordache, Vlad; Catalina, Tiberiu; Croitoru, Cristiana Verona

    2018-02-01

    Nowadays, there is an increasing emphasis on indoor air quality due to technological evolution and the fact that people spend most of the time in enclosed spaces. Also, energy efficiency is another related factor that gains more and more attention. Improving air distribution in an enclosure can lead to achieve these goals. This improvement can be done by adjustingthe air terminals position, theredimensions or the air diffuser perforations. The paper presents the study of 8 types of panels with different perforations shapes. The systems were characterized by flow, pressure loss and noise. Usualand special geometries were chosen, all having the same flowsurface. The perforated panels were mounted in a unidirectional air flow (UAF)diffuser, also called a laminar air flow (LAF)diffuser, that is placed in a real scale operating room (OR) in our laboratory.The purpose of this study is to determine whether changing the shape in the perforated panels can improve the technical parameters of the diffuser.

  5. Ships, ports and particulate air pollution - an analysis of recent studies

    Directory of Open Access Journals (Sweden)

    Mueller Daniel

    2011-12-01

    Full Text Available Abstract The duration of use is usually significantly longer for marine vessels than for roadside vehicles. Therefore, these vessels are often powered by relatively old engines which may propagate air pollution. Also, the quality of fuel used for marine vessels is usually not comparable to the quality of fuels used in the automotive sector and therefore, port areas may exhibit a high degree of air pollution. In contrast to the multitude of studies that addressed outdoor air pollution due to road traffic, only little is known about ship-related air pollution. Therefore the present article aims to summarize recent studies that address air pollution, i.e. particulate matter exposure, due to marine vessels. It can be stated that the data in this area of research is still largely limited. Especially, knowledge on the different air pollutions in different sea areas is needed.

  6. Evaluation of Legionella Air Contamination in Healthcare Facilities by Different Sampling Methods: An Italian Multicenter Study

    Science.gov (United States)

    Montagna, Maria Teresa; De Giglio, Osvalda; Cristina, Maria Luisa; Napoli, Christian; Pacifico, Claudia; Agodi, Antonella; Baldovin, Tatjana; Casini, Beatrice; Coniglio, Maria Anna; D’Errico, Marcello Mario; Delia, Santi Antonino; Deriu, Maria Grazia; Guida, Marco; Laganà, Pasqualina; Liguori, Giorgio; Moro, Matteo; Mura, Ida; Pennino, Francesca; Privitera, Gaetano; Romano Spica, Vincenzo; Sembeni, Silvia; Spagnolo, Anna Maria; Tardivo, Stefano; Torre, Ida; Valeriani, Federica; Albertini, Roberto; Pasquarella, Cesira

    2017-01-01

    Healthcare facilities (HF) represent an at-risk environment for legionellosis transmission occurring after inhalation of contaminated aerosols. In general, the control of water is preferred to that of air because, to date, there are no standardized sampling protocols. Legionella air contamination was investigated in the bathrooms of 11 HF by active sampling (Surface Air System and Coriolis®μ) and passive sampling using settling plates. During the 8-hour sampling, hot tap water was sampled three times. All air samples were evaluated using culture-based methods, whereas liquid samples collected using the Coriolis®μ were also analyzed by real-time PCR. Legionella presence in the air and water was then compared by sequence-based typing (SBT) methods. Air contamination was found in four HF (36.4%) by at least one of the culturable methods. The culturable investigation by Coriolis®μ did not yield Legionella in any enrolled HF. However, molecular investigation using Coriolis®μ resulted in eight HF testing positive for Legionella in the air. Comparison of Legionella air and water contamination indicated that Legionella water concentration could be predictive of its presence in the air. Furthermore, a molecular study of 12 L. pneumophila strains confirmed a match between the Legionella strains from air and water samples by SBT for three out of four HF that tested positive for Legionella by at least one of the culturable methods. Overall, our study shows that Legionella air detection cannot replace water sampling because the absence of microorganisms from the air does not necessarily represent their absence from water; nevertheless, air sampling may provide useful information for risk assessment. The liquid impingement technique appears to have the greatest capacity for collecting airborne Legionella if combined with molecular investigations. PMID:28640202

  7. Evaluation of Legionella Air Contamination in Healthcare Facilities by Different Sampling Methods: An Italian Multicenter Study.

    Science.gov (United States)

    Montagna, Maria Teresa; De Giglio, Osvalda; Cristina, Maria Luisa; Napoli, Christian; Pacifico, Claudia; Agodi, Antonella; Baldovin, Tatjana; Casini, Beatrice; Coniglio, Maria Anna; D'Errico, Marcello Mario; Delia, Santi Antonino; Deriu, Maria Grazia; Guida, Marco; Laganà, Pasqualina; Liguori, Giorgio; Moro, Matteo; Mura, Ida; Pennino, Francesca; Privitera, Gaetano; Romano Spica, Vincenzo; Sembeni, Silvia; Spagnolo, Anna Maria; Tardivo, Stefano; Torre, Ida; Valeriani, Federica; Albertini, Roberto; Pasquarella, Cesira

    2017-06-22

    Healthcare facilities (HF) represent an at-risk environment for legionellosis transmission occurring after inhalation of contaminated aerosols. In general, the control of water is preferred to that of air because, to date, there are no standardized sampling protocols. Legionella air contamination was investigated in the bathrooms of 11 HF by active sampling (Surface Air System and Coriolis ® μ) and passive sampling using settling plates. During the 8-hour sampling, hot tap water was sampled three times. All air samples were evaluated using culture-based methods, whereas liquid samples collected using the Coriolis ® μ were also analyzed by real-time PCR. Legionella presence in the air and water was then compared by sequence-based typing (SBT) methods. Air contamination was found in four HF (36.4%) by at least one of the culturable methods. The culturable investigation by Coriolis ® μ did not yield Legionella in any enrolled HF. However, molecular investigation using Coriolis ® μ resulted in eight HF testing positive for Legionella in the air. Comparison of Legionella air and water contamination indicated that Legionella water concentration could be predictive of its presence in the air. Furthermore, a molecular study of 12 L. pneumophila strains confirmed a match between the Legionella strains from air and water samples by SBT for three out of four HF that tested positive for Legionella by at least one of the culturable methods. Overall, our study shows that Legionella air detection cannot replace water sampling because the absence of microorganisms from the air does not necessarily represent their absence from water; nevertheless, air sampling may provide useful information for risk assessment. The liquid impingement technique appears to have the greatest capacity for collecting airborne Legionella if combined with molecular investigations.

  8. Study on air pollution monitoring in Korea using low volume air sampler by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Yong Sam Chung; Jong Hwa Moon, Young Ju Chung; Seung Yeon Cho; Sang Hun Kang

    1999-01-01

    The aim of this research was to enhance the use of nuclear analytical techniques for air pollution studies and to study the feasibility of the use of instrumental neutron activation analysis (INAA) as a routine monitoring tool to reveal environmental pollution sources. For the collection of air particulate samples, the Gent stacked filter unit, low volume sampler with Nucleopore membrane filters were used. Trace elements in samples collected at two suburban residential sites, Taejon and Wonju city in the Republic of Korea, were analyzed by INAA. Variations of the elemental concentrations were measured monthly and the enrichment factors were calculated for the fine (< 2 μm EAD) and coarse size (2-10 μm EAD) fractions. The analytical data were treated statistically to estimate the relationship between the two variables, the concentrations of elements and the total suspended particulate matter. The results were used to describe the emission source and their correlation. (author)

  9. A Case Study On Human Capital Mismanagement In The United States Air Force

    Science.gov (United States)

    2016-05-08

    AIR COMMAND AND STAFF COLLEGE AIR UNIVERSITY A Case Study on Human Capital Mismanagement in the United States Air Force By John P...Force does not effectively manage its human capital to develop and retain a technically literate acquisitions workforce. A detailed look at the...Several solutions are suggested to improve the human capital management and increase the quality and relevancy of the acquisitions community at

  10. Air pollution and health in Sri Lanka: a review of epidemiologic studies

    OpenAIRE

    Sathiakumar Nalini; Wickremasinghe Ananda R; Nandasena Yatagama

    2010-01-01

    Abstract Background Air pollution is increasingly documented as a threat to public health in most developing countries. Evaluation of current air quality levels, regulatory standards and scientific literature on outdoor and indoor air pollution, and health effects are important to identify the burden, develop and implement interventions and to fill knowledge gaps in Sri Lanka. Methods PUBMED and Medline databases, local journals and conference proceedings were searched for epidemiologic studi...

  11. Mortality, migration, income, and air pollution: a comparative study

    Energy Technology Data Exchange (ETDEWEB)

    Bozzo, S.R.; Novak, K.M.; Galdos, F.; Hakoopian, R.; Hamilton, L.D.

    1978-06-02

    The interrelationships among different demographic factors, specific causes of death, median family income, and estimated air pollution emissions were examined. Using the Medical Data Base (MEDABA) developed at Brookhaven National Laboratory, the entire population of the United States was cross-tabulated by income and emission levels of air pollutants. Path analysis was used to examine a number of patterns and relationships for each age, race, and sex group containing a minimum of 10,000 persons. Competitive and complementary effects were observed. These effects were frequently age dependent and occasionaly sex related. This specialized data base, the application of path analysis, and the development of a dynamic population and mortality model, in combination, proved to be a useful tool for investigating the effects of energy related pollutants on the exposed population.

  12. Experimental study on fundamental phenomena in HTGR small break air-ingress accident

    International Nuclear Information System (INIS)

    Kim, Jae Soon; Hwang, Jin-Seok; Kim, Eung Soo; Kim, Byung Jun; Oh, Chang Ho

    2016-01-01

    Highlights: • Air-ingress phenomena on the small break in a HTGR are experimentally investigated. • Experiment is investigated for various break sizes, angles, and density ratios. • Maximum air-ingress rate is observed at 120° in break angle. • This study reveals that air-ingress in the small break is governed by; buoyancy and flow inertia. • A non-dimensional parameter is newly proposed to determine the air-ingress flow regimes. • Newly proposed parameter is based on buoyancy versus inertia force. - Abstract: This study experimentally investigates fundamental phenomena in the HTGR small break air-ingress accident. Several important parameters including density ratio, break angle, break size, and main flow velocity are considered in the measurement and the analysis. The test-section is made of a circular pipe with small holes drilled around the surface and it is installed in the helium/air flow circulation loop. Oxygen concentrations and flow rates are recorded during the tests with fixed break angles, break sizes, and flow velocities for measurement of the air-ingress rates. According to the experimental results, the higher density difference leads to the higher rates of air-ingress with large sensitivity of the break angles. It is also found that the break angle significantly affects the air-ingress rates, which is gradually increased from 0° to 120° and suddenly decreased to 180°. The minimum air ingress rate is found at 0° and the maximum, at 110°. The air-ingress rate increases with the break size due to the increased flow-exchange area. However, it is not directly proportional to the break area due to the complexity of the phenomena. The increased flow velocity in the channel inside enhances the air-ingress process. However, among all the parameters, the main flow velocity exhibits the lowest effect on this process. In this study, the Froude Number relevant to the small break air-ingress conditions are newly defined considering both heavy

  13. Study of Naval Air Station Operations to Reduce Fuel Consumption

    Science.gov (United States)

    2014-06-01

    reasons and loyalty of frequent business customers , schedules rarely change significantly from week to week. Following the schedule generation, aircraft...Air Station ppm pounds per minute xiv rft ready for tasking SHARP Sierra Hotel Aviation Readiness Program Simio Simulation Modeling Framework...America, the U.S. airline industry experienced a total of $7.18 billion in delay costs in 2013 at an average cost per minute of $78.17 (Airlines

  14. Air quality study of the Islamabad/Rawalpindi region

    International Nuclear Information System (INIS)

    Siddique, N.; Waheed, S.; Daud, M.; Khalid, N.; Arif, M.

    2012-01-01

    Over 1100 pairs of coarse and fine filters were collected using Gent samplers and polycarbonate filters from 4 sites in Islamabad and Rawalpindi from the period 1998 to 2010. The Black carbon (BC) in these samples was determined by reflectance measurement while their elemental composition were determined using the techniques of instrumental neutron activation analysis (INAA), ion beam analysis (IBA) and X-ray fluorescence (XRF) spectrometry. Islamabad is a well planned and relatively small city as compared to Rawalpindi, Lahore or Karachi therefore its air quality is better than the air quality of other major Pakistani cities. It was found that the new air quality standards to be implemented in Pakistan with effect from January 2012 may not be attained even in Islamabad without the implementation of control and remedial measures. An overview of the elemental data obtained and calculation of enrichment factors (EF) and application of positive matrix factorization (PMF) showed that the particles in Islamabad originated from re-suspended soil, vehicular emissions and coal combustion. (Orig./A.B.)

  15. A study on the treatment of radioactive liquid wastes using synthetic by air intake system

    Energy Technology Data Exchange (ETDEWEB)

    Kim, T. G.; Lee, Y. H.; An, S. J.; Son, J. S.; Hong, K. P. [KAERI, Taejon (Korea, Republic of)

    2003-07-01

    In this study based on the mass transfer theory, experiments for the evaporation rates depending on various conditions were carried out through the operation of the existing Natural Evaporation Facility in KAERI. Evaporation media were made of the cotton and polyester. Air circulation in the facility was forced by exhausting fans. The evaporation rate and the decontamination factor were calculated by the result of experiment. The evaporation rate increased as the flow rate of air supply, the feed rate of liquid waste, and the temperature of supplied air increased. As for the humility of supplied air, the evaporation rate was getting higher as the humidity was getting lower. As the result of this study, operation conditions of the Natural Evaporation Facility are optimized as follows; The air temperature above 8C .deg., the air humidity below 70%, the air flow rate 1.14-1.47 m/sec, and the liquid waste feed rate 4.6l/hr.m{sup 2}. The decontamination factor and the radioactivity are 5.1x10{sup 3} and 4.7x10{sup -13}{mu}Ci/ml respectively, at the above mentioned optimum operation conditions. The air factor in the Dalton's equation for evaporation was determined from results of experiment on the temperature, the humidity, and the flow rate of supplied air as following; Eh=(0.0168+0.0141V){delta}H.

  16. A study on the treatment of radioactive liquid wastes using synthetic by air intake system

    International Nuclear Information System (INIS)

    Kim, T. G.; Lee, Y. H.; An, S. J.; Son, J. S.; Hong, K. P.

    2003-01-01

    In this study based on the mass transfer theory, experiments for the evaporation rates depending on various conditions were carried out through the operation of the existing Natural Evaporation Facility in KAERI. Evaporation media were made of the cotton and polyester. Air circulation in the facility was forced by exhausting fans. The evaporation rate and the decontamination factor were calculated by the result of experiment. The evaporation rate increased as the flow rate of air supply, the feed rate of liquid waste, and the temperature of supplied air increased. As for the humility of supplied air, the evaporation rate was getting higher as the humidity was getting lower. As the result of this study, operation conditions of the Natural Evaporation Facility are optimized as follows; The air temperature above 8C .deg., the air humidity below 70%, the air flow rate 1.14-1.47 m/sec, and the liquid waste feed rate 4.6l/hr.m 2 . The decontamination factor and the radioactivity are 5.1x10 3 and 4.7x10 -13 μCi/ml respectively, at the above mentioned optimum operation conditions. The air factor in the Dalton's equation for evaporation was determined from results of experiment on the temperature, the humidity, and the flow rate of supplied air as following; Eh=(0.0168+0.0141V)ΔH

  17. A longitudinal study of air contaminants in a newly built preschool. [Sweden

    Energy Technology Data Exchange (ETDEWEB)

    Berglund, B. (Univ. of Stockholm, Sweden); Johansson, I.; Lindvall, T.

    1982-01-01

    The air quality in a newly built preschool was investigated in a longitudinal study. Typical air contaminants emanating from building materials were determined, their variation over time (0-18 months) was measured, and the influence of the ventilation system (81%-91% recirculation of return air) on contaminant concentrations was studied. Volatile organic compounds were sampled by adsorption on porous polymer, analysed by a GC/FID system, and identified by MS. A spatial build-up in concentration (ppb or ..mu..g/m/sup 3/ levels) is evident for all the organic compounds, as well as for CO/sub 2/, from the outdoor air, through the ventilation system, and through the rooms to the exhaust air. The longitudinal comparison over time shows that all the organic compounds decline in concentration mainly within the first 6 months of occupancy: 1-buttanol 4-14 times, toluene and pentanal + hexanal 2-4 times, while formaldehyde remained at a constant low level of 90 ppb (110 ..mu..g/m/sup 3/). It is difficult to believe that the problems of poor air quality in 100 preschools in Stockholm are caused by the organic compounds alone unless interactions occur. A preschool building needs to be gassed off during the first 6 months after its construction with no recirculation of return air allowed (outdoor air rate approx 4-5 ach). During at least 1-2 additional years, it is desired that the recirculation rate of return air is restricted, perhaps to 50%.

  18. The use of biomonitors and neutron activation analysis in the study of air pollution of Buenos Aires city

    International Nuclear Information System (INIS)

    Pla, R.R.; Moreno, M.A.; Adler, M.

    2000-01-01

    Biomonitors were used as part of a pollution study of Buenos Aires city atmosphere under the International Atomic Energy Agency Research Contract ARG 7251, from the Co-ordinated Research Programme on Applied Research on Air Pollution using Nuclear Related Analytical Techniques. Lichens were primarily selected as indicators. Two different approaches were conducted, direct sampling of Parmotrema reticulatum, at a few places and the use of lichen bags, filled with Usnea sulcata from a northern national park, and hung at different sites. Simultaneously, tree bark was tried as biomonitor. Platanus acerifolia and Melia azedarach were selected as candidates, for being the most common trees in the city, but only P. acerifolia was analyzed. All the samples were analyzed using instrumental neutron activation analysis at the Ezeiza Atomic Centre of the National Atomic Energy Commission. RA-3) reactor was used for the irradiations, determining: As, Ba, Br, Ce, Co, Cr, Cs, Eu, Fe, Hf, K, La, Lu, Na, Rb, Sb, Sc, Sm, Ta, Tb, Th, U, Yb and Zn. Concentration values for P. reticulatum compared well with values from literature. For U. sulcata differences were found among the tested sites and also, for some elements an increasing trend with time was observed. Enrichment factors calculated using Sc as reference and Mason's crustal average concentrations showed vehicules and refuse incineration as contributing sources to the aerosol. Tree bark from Buenos Aires and from a smaller city with mainly agricultural activities were analyzed and the results are coincident with those from lichens. This work is the first and preliminar contribution to the study of Buenos Aires aerosol using biomonitors. (author)

  19. Air quality measurements in urban green areas - a case study

    Science.gov (United States)

    Kuttler, W.; Strassburger, A.

    The influence of traffic-induced pollutants (e.g. CO, NO, NO 2 and O 3) on the air quality of urban areas was investigated in the city of Essen, North Rhine-Westphalia (NRW), Germany. Twelve air hygiene profile measuring trips were made to analyse the trace gas distribution in the urban area with high spatial resolution and to compare the air hygiene situation of urban green areas with the overall situation of urban pollution. Seventeen measurements were made to determine the diurnal concentration courses within urban parks (summer conditions: 13 measurements, 530 30 min mean values, winter conditions: 4 measurements, 128 30 min mean values). The measurements were carried out during mainly calm wind and cloudless conditions between February 1995 and March 1996. It was possible to establish highly differentiated spatial concentration patterns within the urban area. These patterns were correlated with five general types of land use (motorway, main road, secondary road, residential area, green area) which were influenced to varying degrees by traffic emissions. Urban parks downwind from the main emission sources show the following typical temporal concentration courses: In summer rush-hour-dependent CO, NO and NO 2 maxima only occurred in the morning. A high NO 2/NO ratio was established during weather conditions with high global radiation intensities ( K>800 W m -2), which may result in a high O 3 formation potential. Some of the values measured found in one of the parks investigated (Gruga Park, Essen, area: 0.7 km 2), which were as high as 275 μg m -3 O 3 (30-min mean value) were significantly higher than the German air quality standard of 120 μg m -3 (30-min mean value, VDI Guideline 2310, 1996) which currently applies in Germany and about 20% above the maximum values measured on the same day by the network of the North Rhine-Westphalian State Environment Agency. In winter high CO and NO concentrations occur in the morning and during the afternoon rush-hour. The

  20. Performance study of desiccant coated heat exchanger air conditioning system in winter

    International Nuclear Information System (INIS)

    Ge, T.S.; Dai, Y.J.; Wang, R.Z.

    2016-01-01

    mass of humidification and COP increase with increasing regeneration temperature under simulation condition. Also, influences of ambient air temperature and humidity ratio on system performance are discussed to study the feasibility of such system regarding different climatic conditions. Results show that higher humidity ratio of ambient air results in increased humidity ratio of supply air, temperature of ambient air has neglectable effect on supply air. In conclusion, DCHE air conditioning system can be adopted for winter operation with moderate selection of regeneration temperature as well as switch time.

  1. The usefulness of air quality monitoring and air quality impact studies before the introduction of reformulated gasolines in developing countries. Mexico City, a real case study

    Energy Technology Data Exchange (ETDEWEB)

    Bravo, H.A.; Torres, R.J. [Universidad Nacional Autonoma de Mexico (Mexico). Section de Contaminacion Ambiental

    2000-07-01

    Urban air pollution is a major environmental problem in several developing countries in the world. This phenomenon seems to be related to the growth of both the urban population in large cities and the number of old and poorly maintained car fleets. The expected rise of population in the next century in countries which suffer from lack of capital for air pollution control, means that there is a great potential for the worsening of the air quality. The worldwide promote policy to phase out lead in gasolines has not proved to be an adequate option in improving the environmental quality. Mexico City Metropolitan Area (MCMA) represents a case in which the introduction of reformulated gasolines in an old car fleet has resulted in the reduction of the airborne lead levels but has worsened the ozone concentration of its urban atmosphere. This paper critically analyzes the chronological evolution of the ozone air pollution problem in MCMA after the successive occurrence of several changes in the formulation of low leaded and unleaded gasolines. It also presents evidences of the usefulness potential of air quality monitoring activities and air quality impact studies on the definition of realistic fuel reformulation policies of developing countries. (author)

  2. Spatial assessment on ambient air quality status: a case study in ...

    African Journals Online (AJOL)

    Klang as the center of economic and industrial zone in Malaysia has been exposed to poor air quality condition over the years. This study was conducted to evaluate the spatial variation pattern of air quality status in Klang, Selangor by using a four years (2010-2013) secondary database from the Malaysian Department of ...

  3. Extra-Curricular Social Studies in an Open Air History Museum

    Science.gov (United States)

    Morris, Ronald Vaughan

    2008-01-01

    This article discusses extra-curricular social studies in an Open Air History Museum. Open Air History Museum, Conner Prairie Interpretive Park in Fishers, Indiana, is a cultural institution that encourages and supports talented students as they participate in an extra-curricular program. Ten-to sixteen-year-old youths "apply for jobs"…

  4. Relationship Between Air Quality and Outdoor Exercise Behavior in China: a Novel Mobile-Based Study.

    Science.gov (United States)

    Hu, Liang; Zhu, Li; Xu, Yaping; Lyu, Jiaying; Imm, Kellie; Yang, Lin

    2017-08-01

    Based on data collected from an exercise app, the study aims to provide empirical evidence on the relationship between air quality and patterns of outdoor exercise in China. Objective outdoor exercise data spanning 160 days were collected from 153 users of an exercise app, Tulipsport in China. Each exercise mode (running, biking, and walking, respectively) was organized into five air quality categories based on Air Quality Index (AQI): excellent, good, mild pollution, moderate pollution, and serious pollution. Key parameters of each app user were calculated and analyzed: the total number of exercise bouts, the average duration, and the average distance of each exercise mode in each air quality category. Multivariate analyses of variance indicate that the users were less likely to participate in outdoor running, biking, and walking (F = 24.16, p air pollution increased. However, there is no difference in terms of average distance and duration of exercise across different air pollution categories. People's participation in outdoor exercise is impeded by air pollution severity, but they stick to their exercise routines once exercise is initiated. Although people should protect themselves from health damages caused by exercising under pollution, the decreases in physical activity associated with air pollution may also pose an indirect risk to public health. The interactive relationship between air quality, exercise, and health warrants more empirical and interdisciplinary explorations.

  5. Revealing transboundary and local air pollutant sources affecting Metro Manila through receptor modeling studies

    International Nuclear Information System (INIS)

    Pabroa, Preciosa Corazon B.; Bautista VII, Angel T.; Santos, Flora L.; Racho, Joseph Michael D.

    2011-01-01

    Ambient fine particulate matter (PM 2 .5) levels at the Metro Manila air sampling stations of the Philippine Nuclear Research Research Institute were found to be above the WHO guideline value of 10 μg m 3 indicating, in general, very poor air quality in the area. The elemental components of the fine particulate matter were obtained using the energy-dispersive x-ray fluorescence spectrometry. Positive matrix factorization, a receptor modelling tool, was used to identify and apportion air pollution sources. Location of probable transboundary air pollutants were evaluated using HYSPLIT (Hybrid Single Particle Lagrangian Integrated Trajectory Model) while location of probable local air pollutant sources were determined using the conditional probability function (CPF). Air pollutant sources can either be natural or anthropogenic. This study has shown natural air pollutant sources such as volcanic eruptions from Bulusan volcano in 2006 and from Anatahan volcano in 2005 to have impacted on the region. Fine soils was shown to have originated from China's Mu US Desert some time in 2004. Smoke in the fine fraction in 2006 show indications of coming from forest fires in Sumatra and Borneo. Fine particulate Pb in Valenzuela was shown to be coming from the surrounding area. Many more significant air pollution impacts can be evaluated with the identification of probable air pollutant sources with the use of elemental fingerprints and locating these sources with the use of HYSPLIT and CPF. (author)

  6. Vandenberg Air Force Base Pressure Gradient Wind Study

    Science.gov (United States)

    Shafer, Jaclyn A.

    2013-01-01

    Warning category winds can adversely impact day-to-day space lift operations at Vandenberg Air Force Base (VAFB) in California. NASA's Launch Services Program and other programs at VAFB use wind forecasts issued by the 30 Operational Support Squadron Weather Flight (30 OSSWF) to determine if they need to limit activities or protect property such as a launch vehicle. The 30 OSSWF tasked the AMU to develop an automated Excel graphical user interface that includes pressure gradient thresholds between specific observing stations under different synoptic regimes to aid forecasters when issuing wind warnings. This required the AMU to determine if relationships between the variables existed.

  7. A study on thoron decay products in the air

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, A A; Abul-Hussein, A; Mahmoud, M [Physics Dept. Faculty of Science, El-minia Univ., El-Minia (Egypt)

    1997-12-31

    Low pressure Berner cascade impactor technique was used as sampling device to determine the concentration ansd activity size distribution of {sup 212}Pb in the open air. The collected activity in each stage of the impactor was measured by a {gamma} spectrometer with 5 x 5 Nal(tl)detector. The activity size distribution of {sup 212}Pb was described by one long-normal distribution. The mean AMAD was 345 nm with {alpha}{sub 9}=2.7 o. 4 figs., 3 tabs.

  8. Compressed Air Quality, A Case Study In Paiton Coal Fired Power Plant Unit 1 And 2

    Science.gov (United States)

    Indah, Nur; Kusuma, Yuriadi; Mardani

    2018-03-01

    The compressed air system becomes part of a very important utility system in a Plant, including the Steam Power Plant. In PLN’S coal fired power plant, Paiton units 1 and 2, there are four Centrifugal air compressor types, which produce compressed air as much as 5.652 cfm and with electric power capacity of 1200 kW. Electricity consumption to operate centrifugal compressor is 7.104.117 kWh per year. Compressed air generation is not only sufficient in quantity (flow rate) but also meets the required air quality standards. compressed air at Steam Power Plant is used for; service air, Instrument air, and for fly Ash. This study aims to measure some important parameters related to air quality, followed by potential disturbance analysis, equipment breakdown or reduction of energy consumption from existing compressed air conditions. These measurements include counting the number of dust particles, moisture content, relative humidity, and also compressed air pressure. From the measurements, the compressed air pressure generated by the compressor is about 8.4 barg and decreased to 7.7 barg at the furthest point, so the pressure drop is 0.63 barg, this number satisfies the needs in the end user. The measurement of the number of particles contained in compressed air, for particle of 0.3 micron reaches 170,752 particles, while for the particle size 0.5 micron reaches 45,245 particles. Measurements of particles conducted at several points of measurement. For some point measurements the number of dust particle exceeds the standard set by ISO 8573.1-2010 and also NACE Code, so it needs to be improved on the air treatment process. To see the amount of moisture content in compressed air, it is done by measuring pressure dew point temperature (PDP). Measurements were made at several points with results ranging from -28.4 to 30.9 °C. The recommendation of improving compressed air quality in steam power plant, Paiton unit 1 and 2 has the potential to extend the life of

  9. Investigation of heat transfer inside a PCM-air heat exchanger: a numerical parametric study

    Science.gov (United States)

    Herbinger, Florent; Bhouri, Maha; Groulx, Dominic

    2017-07-01

    In this paper, the use of PCMs for thermal storage of energy in HVAC applications was investigated by studying numerically the thermal performance of a PCM-air heat exchanger. The PCM used in this study was dodecanoic acid. A symmetric 3D model, incorporating conductive and convective heat transfer (air only) as well as laminar flow, was created in COMSOL Multiphysics 5.0. Simulations examined the dependence of the heat transfer rate on the temperature and velocity of the incoming air as well as the size of the channels in the heat exchanger. Results indicated that small channels size lead to a higher heat transfer rates. A similar trend was also obtained for high incoming air temperature, whereas the heat transfer rate was less sensitive to the incoming air velocity.

  10. Numerical study of a PCM-air heat exchanger's thermal performance

    Science.gov (United States)

    Herbinger, F.; Bhouri, M.; Groulx, D.

    2016-09-01

    In this paper, the use of PCMs in HVAC applications is investigated by studying numerically the thermal performance of a PCM-air heat exchanger. The PCM used in this study is dodecanoic acid. A symmetric 3D model, incorporating conductive and convective heat transfer (air only) as well as laminar flow, was created in COMSOL Multiphysics 5.0. Simulations examined the dependence of the heat transfer rate on the temperature and velocity of the incoming air as well as the size of the channels in the heat exchanger. Results indicated that small channels size lead to a higher heat transfer rates. A similar trend was also obtained for high incoming air temperature, whereas the heat transfer rate was less sensitive to the incoming air velocity.

  11. Sensitivity studies of air ingress accidents in modular HTGRs

    International Nuclear Information System (INIS)

    Ball, Syd; Richards, Matt; Shepelev, Sergey

    2008-01-01

    Postulated air ingress accidents, while of very low probability in a modular high-temperature gas-cooled reactor (HTGR), are of considerable interest to the plant designer, operator, and regulator because of the possibility that the core could sustain significant damage under some circumstances. Sensitivity analyses are described that cover a wide spectrum of conditions affecting outcomes of the postulated accident sequences, for both prismatic and pebble-bed core designs. The major factors affecting potential core damage are the size and location of primary system leaks, flow path resistances, the core temperature distribution, and the long-term availability of oxygen in the incoming gas from a confinement building. Typically, all the incoming oxygen entering the core area is consumed within the reactor vessel, so it is more a matter of where, not whether, oxidation occurs. An air ingress model with example scenarios and means for mitigating damage are described. Representative designs of modular HTGRs included here are a 400-MW(th) pebble-bed reactor (PBR), and a 600-MW(th) prismatic-core modular reactor (PMR) design such as the gas-turbine modular helium reactor (GT-MHR)

  12. Study of air flow and temperature distribution in ship's crew cabins

    Energy Technology Data Exchange (ETDEWEB)

    Elsafty, A.F. [Arab Academy for Science and Technology and Maritime Transport, Alexandria (Egypt). Dept. of Mechanical and Marine Engineering; Ali, A.A.; Nasr, A.N. [Arab Academy for Science and Technology and Maritime Transport, Alexandria (Egypt). Dept. of Marine Engineering Technology

    2007-07-01

    Because of low internal heights in ship's crew cabins, the supplied air is directed to the persons at low mixing ratios. However, this does not allow the mixing process between the supplied air and the indoor air to be completed before the air enters human lungs. This paper presented an experimental and numerical simulation study that used computational fluid dynamics (CFD) to investigate the effect of the air supply location on thermal air diffusion in the ship's crew cabins space. The paper presented the results in terms of air diffusion performance index. The paper presented the CFD model, including selected space configurations; CFD simulation; boundary conditions; and CFD results. The CFD airflow simulation programs CFD were utilized to calculate the spatial distribution of temperature and velocity. The study focused on the typical Middle East region working vessel under thermal and boundary conditions including the high cooling load used in this region. Experimental data were also introduced to verify the CFD results package. It was concluded that the supply should be located near the high sidewall of the cabin. This gives better air distribution inside the space rather than the center of the room. 5 refs., 1 tab., 6 figs.

  13. Numerical study of the air-flow in an oscillating water column wave energy converter

    Energy Technology Data Exchange (ETDEWEB)

    Paixao Conde, J.M. [Department of Mechanical and Industrial Engineering, Faculty of Sciences and Technology, New University of Lisbon, Monte de Caparica, 2829-516 Caparica (Portugal); IDMEC, Instituto Superior Tecnico, Technical University of Lisbon, 1049-001 Lisboa (Portugal); Gato, L.M.C. [IDMEC, Instituto Superior Tecnico, Technical University of Lisbon, 1049-001 Lisboa (Portugal)

    2008-12-15

    The paper presents a numerical study of the air-flow in a typical pneumatic chamber geometry of an oscillating water column (OWC)-type wave energy converter (WEC), equipped with two vertical-axis air turbines, asymmetrically placed on the top of the chamber. Outwards and inwards, steady and periodic, air-flow calculations were performed to investigate the flow distribution at the turbines' inlet sections, as well as the properties of the air-jet impinging on the water free-surface. The original design of the OWC chamber is likely to be harmful for the operation of the turbines due to the possible air-jet-produced water-spray at the water free-surface subsequently ingested by the turbine. A geometry modification of the air chamber, using a horizontal baffle-plate to deflect the air from the turbines, is proposed and proved to be very effective in reducing the risk of water-spray production from the inwards flow. The flow distribution at the turbines' inlet sections for the outwards flow was found to be fairly uniform for the geometries considered, providing good inlet flow conditions for the turbines. Steady flow was found to be an acceptable model to study the air-flow inside the pneumatic chamber of an OWC-WEC. (author)

  14. Spatial Air Quality Modelling Using Chemometrics Techniques: A Case Study in Peninsular Malaysia

    International Nuclear Information System (INIS)

    Azman Azid; Hafizan Juahir; Mohammad Azizi Amran; Zarizal Suhaili; Mohamad Romizan Osman; Asyaari Muhamad; Asyaari Muhamad; Ismail Zainal Abidin; Nur Hishaam Sulaiman; Ahmad Shakir Mohd Saudi

    2015-01-01

    This study shows the effectiveness of hierarchical agglomerative cluster analysis (HACA), discriminant analysis (DA), principal component analysis (PCA), and multiple linear regressions (MLR) for assessment of air quality data and recognition of air pollution sources. 12 months data (January-December 2007) consisting of 14 stations in Peninsular Malaysia with 14 parameters were applied. Three significant clusters - low pollution source (LPS), moderate pollution source (MPS), and slightly high pollution source (SHPS) were generated via HACA. Forward stepwise of DA managed to discriminate eight variables, whereas backward stepwise of DA managed to discriminate nine variables out of fourteen variables. The PCA and FA results show the main contributor of air pollution in Peninsular Malaysia is the combustion of fossil fuel from industrial activities, transportation and agriculture systems. Four MLR models show that PM_1_0 account as the most and the highest pollution contributor to Malaysian air quality. From the study, it can be stipulated that the application of chemometrics techniques can disclose meaningful information on the spatial variability of a large and complex air quality data. A clearer review about the air quality and a novelty design of air quality monitoring network for better management of air pollution can be achieved via these methods. (author)

  15. Public Health and Air Pollution in Asia (PAPA): A Multicity Study of Short-Term Effects of Air Pollution on Mortality

    OpenAIRE

    Wong, Chit-Ming; Vichit-Vadakan, Nuntavarn; Kan, Haidong; Qian, Zhengmin

    2008-01-01

    Background and Objectives: Although the deleterious effects of air pollution from fossil fuel combustion have been demonstrated in many Western nations, fewer studies have been conducted in Asia. The Public Health and Air Pollution in Asia (PAPA) project assessed the effects of short-term exposure to air pollution on daily mortality in Bangkok, Thailand, and in three cities in China: Hong Kong, Shanghai, and Wuhan. Methods: Poisson regression models incorporating natural spline smoothing func...

  16. Studi Kelayakan Pengolahan Air Laut Menjadi Air Bersih di Kawasan Wisata dan Pelabuhan Perikanan Nusantara (PPN Pantai Prigi, Trenggalek

    Directory of Open Access Journals (Sweden)

    Agista Ayuningtyas Puspita Dwijayani

    2013-09-01

    Full Text Available Ketersediaan air bersih diperlukan pula dalam bidang kepariwisataan. Salah satunya ialah kawasan wisata alam Pantai Prigi, Trenggalek. Namun kondisi air saat ini masih memiliki kandungan TDS (Total Dissolved Solid dan salinitas yang cukup tinggi sehingga dibutuhkan suatu teknologi untuk mengolah air asin menjadi air tawar agar memenuhi standar baku mutu air bersih. Salah satu teknologi yang dapat diterapkan untuk mengolah air asin atau payau menjadi air tawar adalah dengan sistem Reverse Osmosis (RO. Penentuan kapasitas SWRO ditentukan dengan memproyeksikan jumlah pengunjung kawasan wisata Pantai Prigi dan kebutuhan air kolam apung hingga tahun 2023. Hasil proyeksi diperoleh kebutuhan air sebesar 729,40 m3/hari pada penggunaan maksimum. Dengan desain SWRO yaitu menggunakan pretreatment rapid sand filter dan filter karbon aktif untuk meremoval kandungan TDS, kesadahan total, khlorida, sulfat, dan bilangan KMnO4 (zat organik. Biaya yang dibutuhkan untuk membuat sistem pengolahan air laut dengan SWRO sebesar Rp 5.077.307.500,00.Perencanaan sistem pengolahan air laut menjadi layak jika air reject dari SWRO sebesar 1463,28 m3/hari dimanfaatkan menjadi wisata kolam apung, garam, dan air nigari dengan investasi total sebesar Rp 7.326.095.500,00. Dengan analisa kelayakan secara ekonomi  menggunakan prinsip ekonomi teknik, pada alternatif ini diperoleh nilai NPV sebesar Rp 25.024.360.250,24 ; IRR sebesar 23,7% ; dan Payback periode pada tahun ke-3 dengan keuntungan yang diperoleh Rp 3.915.665.044,80 per tahun.

  17. Ftir study of gamma irradiation LDPE film in air

    International Nuclear Information System (INIS)

    Moura, Esperidiana A.B.; Silva, Andre L.A.; Gouvea, Paulo H.D.; Silva, Leonardo G. Andrade e; Gouvea, Douglas; Castro, Ricardo H.R.; Wiebeck, Helio; Kawano, Yoshio

    2003-01-01

    The use of the ionizing radiation for application in plastic packaging, to improve some of properties and for radiation sterilization, has been gaining popularity in the packaging industry. As a consequence of the irradiation, plastic packaging materials can undergo some chemical and physical alterations in their basic function, mainly concerning the protection characteristics. Since changes in physical properties of irradiated packaging films reflect radiation-induced chemical changes in molecular structure, in this work, an investigation was performed by Ftir analysis of LDPE film before and after radiation. Film samples were irradiated with doses between 0 Gy and 100 kGy, at room temperature and in the presence of air. The results showed alterations in the molecular structure, according to the absorbed radiation dose. (author)

  18. Air pollution studies using PIXE and ICP methods

    International Nuclear Information System (INIS)

    Stihi, Claudia; Bancuta, Anca; Popescu, I V; Virgolici, M; Cimpoca, V; Gugiu, M; Vlaicu, Gh

    2006-01-01

    In the present work the moss biomonitoring technique and the combination of two analytical techniques - Particle Induced X-ray Emission (PIXE) and Inductively Coupled Plasma (ICP) - were applied for assessing environmental situation from the point of view of air polluting along the transect from north to south of the Dambovita County. PIXE analysis at the Tandem Accelerator FN-8 of the National Institute of Nuclear Physics - Horia Hulubei of Magurele, Bucharest, allowed determination of P, S, Cl, K, Ca, Mn, Fe, Ni, Cu, Zn, As, Sr, Cd and Pb in samples. ICP analyses were made using a Baird ICP2070 - Sequential Plasma Spectrometer in Targoviste and we determined in samples the concentration of Li, B, Na, and Mg together with Cd and Pb. The obtained results will permit to determine the regional extent of heavy metals and toxic elements atmospheric pollution and to identify specially affected areas and local sources of

  19. Study on heat and mass transfer characteristics of humid air-flow in a fin bundle

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong-Hwi [Air-Conditioner Research Laboratory, LG Electronics, Seoul 153-082 (Korea); Koyama, Shigeru; Kuwahara, Ken [Department of Energy and Environmental Engineering, Kyushu University, Kasuga, Fukuoka 816-8580 (Japan); Kwon, Jeong-Tae [Department of Mechanical Engineering, Hoseo University, Asan, Chungnam 336-795 (Korea); Park, Byung-Duck [School of Mechanical and Automotive Engineering, Kyungpook National University, Sangju, Gyeongbuk 742-711 (Korea)

    2010-11-15

    This paper deals with the heat and mass transfer characteristics of humid air-flow under frosting conditions. A slit fin bundle was used for the simulation of fins of a heat exchanger. The effects of the cooling block temperature, air humidity and air velocity on the frosting characteristics were experimentally investigated. The frosted mass was affected considerably by the cooling block temperature and air humidity. However, the effect of air velocity on it was not so large. The pressure drop was affected remarkably by all experimental parameters in this study. Local heat flux distribution and frost thickness distribution on each fin were predicted from the measured fin temperatures and the mass and energy conservation equations on the frost surface and inside the frost layer. (author)

  20. Experimental and simulation studies on a single pass, double duct solar air heater

    Energy Technology Data Exchange (ETDEWEB)

    Forson, F.K. [Kwame Nkrumah Univ. of Science and Technology, Dept. of Mechanical Engineering, Kumasi (Ghana); Rajakaruna, H. [De Montfort Univ., School of Engineering and Technology, Leicester (United Kingdom)

    2003-05-01

    A mathematical model of a single pass, double duct solar air heater (SPDDSAH) is described. The model provides a design tool capable of predicting: incident solar radiation, heat transfer coefficients, mean air flow rates, mean air temperature and relative humidity at the exit. Results from the simulation are presented and compared with experimental ones obtained on a full scale air heater and a small scale laboratory one. Reasonable agreement between the predicted and measured values is demonstrated. Predicted results from a parametric study are also presented. It is shown that significant improvement in the SPDDSAH performance can be obtained with an appropriate choice of the collector parameters and the top to bottom channel depth ratio of the two ducts. The air mass flow rate is shown to be the dominant factor in determining the overall efficiency of the heater. (Author)

  1. An experimental setup for the study of the steady air flow in a diesel engine chamber

    Directory of Open Access Journals (Sweden)

    Montanero José María

    2012-04-01

    Full Text Available We present an experimental setup for studying the steady air flow in a diesel engine chamber. An engine block containing the inlet manifold was placed on a test bench. A steady air stream crossed the inlet manifold and entered a glass chamber driven by a fan. A PIV system was set up around the bench to measure the in-chamber flow. An air spray gun was used as seed generator to producing sub-millimeter droplets, easily dragged by the air stream. Images of the in-flow chamber were acquired in the course of the experiments, and processed to measure the velocity field. The pressure drop driven the air current and the mass flow rate were also measured.

  2. Studies on the tritium contamination of the ambient air near nuclear facilities with large tritium inventory

    International Nuclear Information System (INIS)

    Friedrich, W.; Knieper, J.; Printz, H.; Sauermann, P.F.

    1976-01-01

    A part of gaseous T is converted to HTO with the humidity in the air. Since HTO has considerably more radiotoxicity than T-gas it is very important to know the extent of this conversion. This question was studied on a 14-MeV-neutron generator with open target system in which, as we know, a major part of the gaseous T originally contained in the T-target is released into the waste air via the vacuum system. The exchange rates in the breathing air in working rooms, in the waste air duct and in the free atmosphere under different meteorological conditions were measured. Furthermore the exchange rate in closed test-circulations was tested in dependence on air humidity, temperature, T-concentration, and time. The T-test instruments were calibrated with gaseous T. (orig./HP) [de

  3. A longitudinal study of mortality and air pollution for São Paulo, Brazil.

    Science.gov (United States)

    Botter, Denise A; Jørgensen, Bent; Peres, Antonieta A Q

    2002-09-01

    We study the effects of various air-pollution variables on the daily death counts for people over 65 years in São Paulo, Brazil, from 1991 to 1993, controlling for meteorological variables. We use a state space model where the air-pollution variables enter via the latent process, and the meteorological variables via the observation equation. The latent process represents the potential mortality due to air pollution, and is estimated by Kalman filter techniques. The effect of air pollution on mortality is found to be a function of the variation in the sulphur dioxide level for the previous 3 days, whereas the other air-pollution variables (total suspended particulates, nitrogen dioxide, carbon monoxide, ozone) are not significant when sulphur dioxide is in the equation. There are significant effects of humidity and up to lag 3 of temperature, and a significant seasonal variation.

  4. Clean air renewable energy (CARE) coalition : a case study

    Energy Technology Data Exchange (ETDEWEB)

    Lambert, G. [Suncor Energy, Fort McMurray, AB (Canada); Pollock, D. [Pembina Institute for Appropriate Development, Drayton Valley, AB (Canada)

    2002-07-01

    This paper highlights the opportunity for new partnerships between business and non-governmental organizations in the field of sustainable development through the growing convergence of interests. The authors also briefly describe both Suncor Energy and the Pembina Institute for Appropriate Development stances on sustainable development. Since 1990, both organizations have collaborated on the future of the emerging renewable energy industry. Renewable energy represents an energy source diversification through the regional creation of jobs and improved air quality and associated benefits resulting from the reductions in greenhouse gas emissions. The Clean Air Renewable Energy Coalition (Coalition) was established in December 2000 in order to assess the barriers to capital investment in the renewable energy industry. It was revealed that the international community as a whole was further ahead than Canada in terms of renewable support, production and export of technology and services. Some of the challenges facing the industry are: low demand for renewables and low supply. The coalition allowed for the joint identification of desired policy changes, such as new tax incentives for renewable energy supply and demand. Efforts were made in inviting the support of industry, municipalities and environmental non governmental organizations. The list of members that have joined the coalition to date was shown. The coalition is asking for consumer green energy credit, designed for the creation of demand and the education of the general public, and producer incentives to increase supply. The proposals were explained, as well as the strategic principles underlying them. A new tax incentive was announced in the December 2001 Canadian federal budget. The authors concluded by mentioning some future opportunities and the lessons learned on the importance of the right partners, of broad-based advocacy, of targeted and focuses messages, and of evolutionary change.

  5. Clean air renewable energy (CARE) coalition : a case study

    International Nuclear Information System (INIS)

    Lambert, G.; Pollock, D.

    2002-01-01

    This paper highlights the opportunity for new partnerships between business and non-governmental organizations in the field of sustainable development through the growing convergence of interests. The authors also briefly describe both Suncor Energy and the Pembina Institute for Appropriate Development stances on sustainable development. Since 1990, both organizations have collaborated on the future of the emerging renewable energy industry. Renewable energy represents an energy source diversification through the regional creation of jobs and improved air quality and associated benefits resulting from the reductions in greenhouse gas emissions. The Clean Air Renewable Energy Coalition (Coalition) was established in December 2000 in order to assess the barriers to capital investment in the renewable energy industry. It was revealed that the international community as a whole was further ahead than Canada in terms of renewable support, production and export of technology and services. Some of the challenges facing the industry are: low demand for renewables and low supply. The coalition allowed for the joint identification of desired policy changes, such as new tax incentives for renewable energy supply and demand. Efforts were made in inviting the support of industry, municipalities and environmental non governmental organizations. The list of members that have joined the coalition to date was shown. The coalition is asking for consumer green energy credit, designed for the creation of demand and the education of the general public, and producer incentives to increase supply. The proposals were explained, as well as the strategic principles underlying them. A new tax incentive was announced in the December 2001 Canadian federal budget. The authors concluded by mentioning some future opportunities and the lessons learned on the importance of the right partners, of broad-based advocacy, of targeted and focuses messages, and of evolutionary change

  6. Pathologic analysis of control plans for air pollution management in tehran metropolis: a qualitative study.

    Science.gov (United States)

    Shahrabi, Narges Salehi; Pourezzat, Aliasghar; Ahmad, Fayaz-Bakhsh; Mafimoradi, Shiva; Poursafa, Parinaz

    2013-09-01

    Regarding the importance of air pollution issue for large cities, as Tehran metropolis, many plans, programs, projects and regulations have been developed to manage urban air pollution. However, most of them failed to decline the pollution. The purpose of this study is to pathologically analyze air-pollution control plans in order to offer effective solutions for Tehran metropolis. A qualitative content analysis and a semi-structured interview with 14 practicing professionals were used to identify key causes and sources of Tehran's air pollution, to recognize challenges and obstacles towards effective performance of air-pollution control plans in this metropolitan area, and to suggest the most effective controlling solutions. Challenges related to air-pollution control plans can be divided into two major categories: Firstly lack of integrated and organized stewardship and secondly those related to political, economical, social and technical environmental abbreviated as PEST, challenges. For effective control of the Tehran air pollution, the following eight controlling alternatives were identified: Systematization of plan preparation process, organizing the stewardship, standardization and utilization of new technologies and professional experts, cultural and infrastructural development, realization of social justice, developing coordination and controlling mechanisms, improving citizen's participatory capacity, and focusing on effective management of fuel and energy. Controlling air pollution in Tehran should be considered as a priority for policymakers to make enforcements through applying a systemic cycle of preparation effective and comprehensive plans. Further, implement the enforcements and evaluate the environmental impact of the plans through involving all stakeholders.

  7. Situation of regional plans for air quality. Acknowledgement of sanitary aspects. Situation of realised impact studies of urban air pollution

    International Nuclear Information System (INIS)

    D'Helf, M.; Cassadou, S.

    2005-01-01

    The law on air and use of energy recommended in 1996 the implementation of regional plans for air quality (P.Q.R.A.) that have to rely on an evaluation of air pollution effects on health. 21 P.Q.R.A. have been published and the report gives the situation, their sanitary orientations and their applications. An inquiry lead in the 21 regions, near the different regional actors in the air and health field completes the report. (N.C.)

  8. Use of a sealant to prevent prolonged air leaks after lung resection: a prospective randomized study.

    Science.gov (United States)

    Lequaglie, Cosimo; Giudice, Gabriella; Marasco, Rita; Morte, Aniello Della; Gallo, Massimiliano

    2012-10-08

    Pulmonary air leaks are common complications of lung resection and result in prolonged hospital stays and increased costs. The purpose of this study was to investigate whether, compared with standard care, the use of a synthetic polyethylene glycol matrix (CoSeal®) could reduce air leaks detected by means of a digital chest drain system (DigiVent™), in patients undergoing lung resection (sutures and/or staples alone). Patients who intraoperatively showed moderate or severe air leaks (evaluated by water submersion tests) were intraoperatively randomized to receive just sutures/staples (control group) or sutures/staples plus CoSeal® (sealant group). Differences among the groups in terms of air leaks, prolonged air leaks, time to chest tube removal, length of hospital stay and related costs were assessed. In total, 216 lung resection patients completed the study. Nineteen patients (18.1%) in the control group and 12 (10.8%) patients in the sealant group experienced postoperative air leaks, while a prolonged air leak was recorded in 11.4% (n=12) of patients in the control group and 2.7% (n=3) of patients in the sealant group. The difference in the incidence of air leaks and prolonged air leaks between the two groups was statistically significant (p=0.0002 and p=0.0013). The mean length of hospital stay was significantly shorter in the sealant group (4 days) than the control group (8 days) (p=0.0001). We also observed lower costs in the sealant group than the control group. The use of CoSeal® may decrease the occurrence and severity of postoperative air leaks after lung resection and is associated with shorter hospital stay. Not registered. The trial was approved by the Institutional Review Board of the IRCCS-CROB Basilicata Regional Cancer Institute, Rionero in Vulture, Italy.

  9. A simulation study of the effects of communication delay on air traffic control

    Science.gov (United States)

    1990-09-01

    This study was conducted to examine the impacts of voice communications delays : characteristic of Voice Switching and Control System (VSCS) and satellite : communications systems on air traffic system performance, controller stress : and workload, a...

  10. A comparative study on indoor air quality in a low cost and a green ...

    African Journals Online (AJOL)

    user

    A statistical correlation analysis of indoor concentration levels with outdoor concentrations was carried ... New studies around the world on the health effects of air pollution ... benefits at all levels from using green affordable housing practices ...

  11. A Study of Air Quality and its Effect on Health: A Geographical Perspective of Lucknow city

    Directory of Open Access Journals (Sweden)

    Dipak Prasad

    2016-06-01

    Full Text Available Erudite groups of people, scientists, planners, and policy-makers of different countries have come to realise that quality of environment is not necessarily a simple function of nature as in primitive earth. Today nature’s self-regulatory functions are inoperative. All the developed and developing countries are deeply concerned to make balance between their environmental anxiety and their economic development. Dreadful environmental conditions are affecting the biological segment of the ecosystem of these areas. Human being, ‘one of the most precious component in biosphere’, have regular predicament situation with accretion of sullied air, water, and soil degradation. Though water and land pollution is extremely dangerous, air pollution has its own peculiarities, due to its trans-boundary dispersion of pollutants over the entire world. The effect of air pollution on health is very complex as there are many different sources and their individual effect varying from one to other. It is not only the ambient air quality in the cities but also the indoor air quality in the rural and urban areas that are causing concern. The study is confined with the health impact of deteriorating air quality in Lucknow city. The aim of the present study is also to determine the consequences of ambient air quality on health of the people in the study area.

  12. Experimental study of air delivery into water-conveyance system of the radial-axial turbine

    Science.gov (United States)

    Maslennikova, Alexandra; Platonov, Dmitry; Minakov, Andrey; Dekterev, Dmitry

    2017-10-01

    The paper presents an experimental study of oscillatory response in the Francis turbine of hydraulic unit. The experiment was performed on large-scale hydrodynamic test-bench with impeller diameter of 0.3 m. The effect of air injection on the intensity of pressure pulsations was studied at the maximum pressure pulsations in the hydraulic unit. It was revealed that air delivery into the water-conveyance system of the turbine results in almost two-fold reduction of pressure pulsations.

  13. Study of short atmospheric pressure dc glow microdischarge in air

    Science.gov (United States)

    Kudryavtsev, Anatoly; Bogdanov, Eugene; Chirtsov, Alexander; Emelin, Sergey

    2011-10-01

    The results of experiments and simulations of short (without positive column) atmospheric pressure dc glow discharge in air are presented. We used metal steel electrodes with a gap of 5-100 microns. The experimental voltage-current characteristic's (VAC) have a constant or slightly increasing form at low gap. The most stable microdischarges were burning with a flat cathode and rounded anode, when the length of the discharge is automatically established near the minimum of the Paschen curve by changing their binding on the anode. In this case microdischarge was stable and it had growing VAC. For simulations we used 2D fluid model with kinetic description of electrons. We solved the balance equations for the vibrationally- and the electronically-excited states of a nitrogen and oxygen molecules; nitrogen and oxygen atoms; ozone molecule; and different nitrogen and oxygen ions with different plasmochemical reactions between them. Simulations predicted the main regions of the dc glow discharges including cathode and anode sheath and plasma of negative glow, Faraday dark space and transition region. Gas heating plays an important role in shaping the discharge profiles. The results of experiments and simulations of short (without positive column) atmospheric pressure dc glow discharge in air are presented. We used metal steel electrodes with a gap of 5-100 microns. The experimental voltage-current characteristic's (VAC) have a constant or slightly increasing form at low gap. The most stable microdischarges were burning with a flat cathode and rounded anode, when the length of the discharge is automatically established near the minimum of the Paschen curve by changing their binding on the anode. In this case microdischarge was stable and it had growing VAC. For simulations we used 2D fluid model with kinetic description of electrons. We solved the balance equations for the vibrationally- and the electronically-excited states of a nitrogen and oxygen molecules; nitrogen

  14. Prevalence of systemic air-embolism after prolonged cardiopulmonary resuscitation in newborns: A pilot study.

    Science.gov (United States)

    Halbertsma, Feico J J; Mohns, Thilo; Bok, Levinus A; Niemarkt, Hendrik J; Kramer, Boris W

    2015-08-01

    Chest compressions (CC) during cardiopulmonary resuscitation (CPR) are the cornerstone of adult CPR protocols and are meant to restore circulation and improve outcome. Although adverse effects such as air-embolisms have been reported, these are rare and considered to be outweighed by beneficial effect. In newborns, however, the lung tissue is more fragile. Thus, the high intra-thoracic pressures resulting from CC may make the newborns more vulnerable for air-embolisms. We studied the postmortem prevalence of air-embolism in neonates that have received CPR. Prospective cohort analysis of newborns receiving CC during CPR. CPR was performed by trained staff according to ILCOR guidelines, in a tertiary hospital. Air-embolisms were sought after using CT/MRI and autopsy. During a 61/2 year period (2007-2014), n = 56 newborns received CC. Newborns were resuscitated following severe perinatal hypoxia, or due to complications during NICU treatment. In n = 14 (25.0%) circulation could not be restored (mean CPR duration: 32.7 ± 15.2 min). Post-mortem CT/MRI was performed in n = 9, of whom n = 8 (88.9%) had air-embolisms. Autopsy was performed in n = 9. The air-embolisms could not be retraced on autopsy except for n = 1 patient. In patients with CPR resulting in restored circulation (n = 42), no CT or MRI was performed for comparison due to radiation and/or hemodynamic instability. Cerebral ultrasound could not identify or exclude air-embolisms in this subgroup. Post-mortem CT after prolonged resuscitation showed a high prevalence of intravascular air-embolism. Autopsy was not suited to detect air-embolism. The clinical importance of air-embolisms on the lethal outcome needs further research. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  15. Effects of long-term exposure to traffic-related air pollution on respiratory and cardiovascular mortality in the Netherlands: the NLCS-AIR study.

    NARCIS (Netherlands)

    Brunekreef, B.|info:eu-repo/dai/nl/067548180; Beelen, R.M.J.|info:eu-repo/dai/nl/30483100X; Hoek, G.|info:eu-repo/dai/nl/069553475; Schouten, L.J.; Bausch-Goldbohm, S.; Fischer, P.; Armstrong, B.; Hughes, E.; Jerrett, M.; v.d. Brandt, P.A.

    2009-01-01

    Evidence is increasing that long-term exposure to ambient air pollution is associated with deaths from cardiopulmonary diseases. In a 2002 pilot study, we reported clear indications that traffic-related air pollution, especially at the local scale, was related to cardiopulmonary mortality in a

  16. Spatial and temporal air quality pattern recognition using environmetric techniques: a case study in Malaysia.

    Science.gov (United States)

    Syed Abdul Mutalib, Sharifah Norsukhairin; Juahir, Hafizan; Azid, Azman; Mohd Sharif, Sharifah; Latif, Mohd Talib; Aris, Ahmad Zaharin; Zain, Sharifuddin M; Dominick, Doreena

    2013-09-01

    The objective of this study is to identify spatial and temporal patterns in the air quality at three selected Malaysian air monitoring stations based on an eleven-year database (January 2000-December 2010). Four statistical methods, Discriminant Analysis (DA), Hierarchical Agglomerative Cluster Analysis (HACA), Principal Component Analysis (PCA) and Artificial Neural Networks (ANNs), were selected to analyze the datasets of five air quality parameters, namely: SO2, NO2, O3, CO and particulate matter with a diameter size of below 10 μm (PM10). The three selected air monitoring stations share the characteristic of being located in highly urbanized areas and are surrounded by a number of industries. The DA results show that spatial characterizations allow successful discrimination between the three stations, while HACA shows the temporal pattern from the monthly and yearly factor analysis which correlates with severe haze episodes that have happened in this country at certain periods of time. The PCA results show that the major source of air pollution is mostly due to the combustion of fossil fuel in motor vehicles and industrial activities. The spatial pattern recognition (S-ANN) results show a better prediction performance in discriminating between the regions, with an excellent percentage of correct classification compared to DA. This study presents the necessity and usefulness of environmetric techniques for the interpretation of large datasets aiming to obtain better information about air quality patterns based on spatial and temporal characterizations at the selected air monitoring stations.

  17. Impact of wood burning on outdoor air quality: existing French data and current studies

    International Nuclear Information System (INIS)

    Leoz-Garziandia, E.; Mandin, C.; Collet, S.; Besombes, J.L.; Pissot, N.; Allemand, N.; Riberon, J.; Jaffrezo, J.L.

    2009-01-01

    French source apportionment studies of air quality including the wood combustion source become widespread. Quantify a single source contribution to air quality requires to be provided with a specific measurable data to this source. For that reason, numerous studies have focused on the determination, in the atmospheric samples, of the source-specific compounds, usually called molecular tracers. Since 2000, trend works focused on the 'wood combustion' contribution to air quality have been based on the use of some tracers such as levoglucosan and metoxyphenols. Obtained results have been compared to atmospheric particles global characteristics: organic carbon (OC), elementary carbon (EC), PM 10 , PM 2.5 and polycyclic aromatic hydrocarbons (PAH). The results presented in this article show not only the interest but also the limits of such an approach, as well as the need to develop and complete the current studies in order to quantify the different sources contribution to air quality. (author)

  18. Braking and cornering studies on an air cushion landing system

    Science.gov (United States)

    Daugherty, R. H.

    1983-01-01

    An experimental investigation was conducted to evaluate several concepts for braking and steering a vehicle equipped with an air cushion landing system (ACLS). The investigation made use of a modified airboat equipped with an ACLS. Braking concepts were characterized by the average deceleration of the vehicle. Reduced lobe flow and cavity venting braking concepts were evaluated in this program. The cavity venting braking concept demonstrated the best performance, producing decelerations on the test vehicle on the same order as moderate braking with conventional wheel brakes. Steering concepts were evaluated by recording the path taken while attempting to follow a prescribed maneuver. The steering concepts evaluated included using rudders only, using differential lobe flow, and using rudders combined with a lightly loaded, nonsteering center wheel. The latter concept proved to be the most accurate means of steering the vehicle on the ACLS, producing translational deviations two to three times higher than those from conventional nose-gear steering. However, this concept was still felt to provide reasonably precise steering control for the ACLS-equipped vehicle.

  19. STUDI OZONISASI SENYAWA ORGANIK AIR LINDI TEMPAT PEMROSESAN AKHIR SARIMUKTI

    Directory of Open Access Journals (Sweden)

    Arya Rezagama

    2013-10-01

    Full Text Available Existing treatment leachate from Sarimukti Landfill doesn’t meet the quality standards of waste water.Preliminary treatment is necessary to break down persistent leachate compounds. Ozone can act directly orindirectly with organic material (Glaze 1986. Column batch reactor system use one liter volume. Ozone ispumped into the leachate in the form of fine bubbles. Variations include Ozone Pumping Flow, Ratio ofhigh/diameter (t/d, and pH. Kinetic Reaction of oxygen dissolution in the average leachate is zero order.Increased pumping air discharge and increased pH makes ozone transfer process better. Best value occurs at pH11, where the value of the reaction rate constant ozone 1.48. The average percentage of organic materialallowance 31% COD and 26% TOC. The decline TOC and COD have a tendency to be influenced by the pHoptimum 8-9. At alkaline pH makes carbonate (CO3 formed the greater, that make ozone compounds killquickly. FTIR results showed the intensity of hydroxyl groups increased after ozone oxidation where thesubstitution of functional groups of organic matter associated with electrophilic addition reaction of oxygenatoms. Existence Fulfic acid also increased the effect compounds and Humic Acid, Humad large has been cut byradicals.

  20. Particulate air pollution and vascular reactivity: the bus stop study.

    Science.gov (United States)

    Dales, Robert; Liu, Ling; Szyszkowicz, Mietek; Dalipaj, Mary; Willey, Jeff; Kulka, Ryan; Ruddy, Terrence D

    2007-11-01

    Particulate air pollution is associated with cardiovascular morbidity but mechanisms are not well understood. We tested the effects on vascular reactivity of exposure to fine particulates matter mass (PM(2.5)), number of particles bus stops. Flow-mediated vasodilation (FMD) of the brachial artery was then measured by ultrasound and expressed as: (maximum artery diameter after release of a blood pressure cuff inflated above systolic pressure-baseline resting diameter)/baseline resting diameter. A 30 microg/m(3) increase in PM(2.5) exposure corresponded to a 0.48% reduction in FMD, P=0.05 representing a 5% relative change in the maximum ability to dilate. Results were consistent between the two bus stops and not sensitive to type of analysis. No significant association was found between FMD and NO(2), PM(1.0) or traffic density. PM(2.5) may reduce the capacity to vasodilate, a potential explanation for the documented association with cardiovascular morbidity.

  1. An experimental study of the air humidification process using a membrane contactor

    Directory of Open Access Journals (Sweden)

    Englart Sebastian

    2017-01-01

    Full Text Available The article presents the results of the experimental examination of the effectiveness of air humidification using a membrane module. The construction of the membrane module and the measuring stand is also discussed. In order to assess the effectiveness of air humidification using the membrane module, the measurements of temperature and humidity at the membrane module’s inlet and outlet, air flow rate, water flow rate and water temperature were taken. Based on the measurements, the effectiveness coefficients, E, have been determined. The power demand for the solution under study has also been discussed.

  2. A case study on determining air monitoring requirements in a radioactive materials handling area

    International Nuclear Information System (INIS)

    Newton, G.J.; Bechtold, W.E.; Hoover, M.D.; Ghanbari, F.; Herring, P.S.; Jow, Hong-Nian

    1993-01-01

    A technical, defensible basis for the number and placement of air sampling instruments in a radioactive materials handling facility was developed. Historical air sampling data, process and physicochemical knowledge, qualitative smoke dispersion studies with video documentation, and quantitative trace gas dispersion studies were used to develop a strategy for number and placement of air samplers. These approaches can be used in other facilities to provide a basis for operational decisions. The requirements for retrospective sampling, personal sampling, and real-time monitoring are included. Other relevant operational decisions include selecting the numbers, placement, and appropriate sampling rates for instruments, identifying areas of stagnation or recirculation, and determining the adequacy and efficiency of any sampling transport lines. Justification is presented for using a graded approach to characterizing the workplace and determining air sampling and monitoring needs

  3. Analytical and Experimental Study of Recycling Baffled Double-Pass Solar Air Heaters with Attached Fins

    Directory of Open Access Journals (Sweden)

    Chun Sheng Lin

    2013-03-01

    Full Text Available The study of the heat transfer of solar air heaters with a new design using an absorbing plate with fins and baffles, which facilitate the recycling of flowing air, is reported. The mathematical formulation and analytical analysis for such a recyclic baffled double-pass solar air heater were developed theoretically. The performance of the device was studied experimentally as well. The theoretical predicted and experimental results were compared with another design, i.e., a downward-type single-pass solar air heater without recycle and double-pass operations reported in our previous work. Significant improvement in heat-transfer efficiency is achieved with the baffle and fin design due to the recycling heating and the extended heat transfer area. The effects of mass flow rate and recycle ratio on the heat-transfer efficiency enhancement as well as on the power consumption increment are also discussed.

  4. Experimental study on 800 nm femtosecond laser ablation of fused silica in air and vacuum

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Shi-zhen, E-mail: xusz@uestc.edu.cn [School of Physical Electronics, University of Electronic Science and Technology of China, Chengdu 610054 (China); Research Center of Laser Fusion, China Academy of Engineering Physics, Mianyang 621900 (China); Yao, Cai-zhen; Liao, Wei [Research Center of Laser Fusion, China Academy of Engineering Physics, Mianyang 621900 (China); Yuan, Xiao-dong, E-mail: yxd66my@163.com [Research Center of Laser Fusion, China Academy of Engineering Physics, Mianyang 621900 (China); Wang, Tao [School of Physical Electronics, University of Electronic Science and Technology of China, Chengdu 610054 (China); Research Center of Laser Fusion, China Academy of Engineering Physics, Mianyang 621900 (China); Zu, Xiao-tao [School of Physical Electronics, University of Electronic Science and Technology of China, Chengdu 610054 (China)

    2016-10-15

    Ablation rates of fused silica were studied as a function of femtosecond laser pulse fluences (0.7–41 J/cm{sup 2}) in air and vacuum. The experiment was conducted by using a Ti:sapphire laser that emits radiation at 800 nm with a pulse width of 35 fs and a repetition rate of 10 Hz. The morphology and ablation depth of laser-induced damage crater were evaluated by using optical microscopy and scanning electron microscopy (SEM). Ablation rates were calculated from the depth of craters induced by multiple laser pulses. Results showed that two ablation regimes, i.e. non-thermal and thermal ablation co-existed in air and vacuum at low and moderate fluences. A drop of ablation rate was observed at high fluence (higher than 9.5 J/cm{sup 2}) in air. While in vacuum, the ablation rate increased continuously with the increasing of laser fluence and much higher than that in air. The drop of ablation rate observed at high fluence in air was due to the strong defocusing effects associated with the non-equilibrium ionization of air. Furthermore, the laser-induced damage threshold (LIDT), which was determined from the relationship between crater area and the logarithm of laser energy, was found to depend on the number of incident pulses on the same spot, and similar phenomenon was observed in air and vacuum.

  5. Exposure to Air Ions in Indoor Environments: Experimental Study with Healthy Adults

    Directory of Open Access Journals (Sweden)

    Peter Wallner

    2015-11-01

    Full Text Available Since the beginning of the 20th century there has been a scientific debate about the potential effects of air ions on biological tissues, wellbeing and health. Effects on the cardiovascular and respiratory system as well as on mental health have been described. In recent years, there has been a renewed interest in this topic. In an experimental indoor setting we conducted a double-blind cross-over trial to determine if higher levels of air ions, generated by a special wall paint, affect cognitive performance, wellbeing, lung function, and cardiovascular function. Twenty healthy non-smoking volunteers (10 female, 10 male participated in the study. Levels of air ions, volatile organic compounds and indoor climate factors were determined by standardized measurement procedures. Air ions affected the autonomous nervous system (in terms of an increase of sympathetic activity accompanied by a small decrease of vagal efferent activity: In the test room with higher levels of air ions (2194/cm3 vs. 1038/cm3 a significantly higher low to high frequency ratio of the electrocardiography (ECG beat-to-beat interval spectrogram was found. Furthermore, six of nine subtests of a cognitive performance test were solved better, three of them statistically significant (verbal factor, reasoning, and perceptual speed, in the room with higher ion concentration. There was no influence of air ions on lung function and on wellbeing. Our results indicate slightly activating and cognitive performance enhancing effects of a short-term exposure to higher indoor air ion concentrations.

  6. Research project on “A Study in Urban Air Pollution Improvement in Asia”

    OpenAIRE

    2017-01-01

    This final report of the joint research project “A study in urban air pollution improvement in Asia” is submitted by the Asian Institute of Technology (AIT) on behalf of the project team following the contract between AIT and the Japan International Cooperation Agency (JICA) for the project period of March 2015 - December 2017. Technical support is provided by the Asia Center for Air Pollution Research (ACAP) Japan and the operational support is provided by the Pollution Control Department (P...

  7. PubMed search filters for the study of putative outdoor air pollution determinants of disease

    OpenAIRE

    Curti, Stefania; Gori, Davide; Di Gregori, Valentina; Farioli, Andrea; Baldasseroni, Alberto; Fantini, Maria Pia; Christiani, David C; Violante, Francesco S; Mattioli, Stefano

    2016-01-01

    Objectives: Several PubMed search filters have been developed in contexts other than environmental. We aimed at identifying efficient PubMed search filters for the study of environmental determinants of diseases related to outdoor air pollution. Methods: We compiled a list of Medical Subject Headings (MeSH) and non-MeSH terms seeming pertinent to outdoor air pollutants exposure as determinants of diseases in the general population. We estimated proportions of potentially pertinent articles to...

  8. Use of a sealant to prevent prolonged air leaks after lung resection: a prospective randomized study

    OpenAIRE

    Lequaglie Cosimo; Giudice Gabriella; Marasco Rita; Morte Aniello; Gallo Massimiliano

    2012-01-01

    Abstract Background Pulmonary air leaks are common complications of lung resection and result in prolonged hospital stays and increased costs. The purpose of this study was to investigate whether, compared with standard care, the use of a synthetic polyethylene glycol matrix (CoSeal®) could reduce air leaks detected by means of a digital chest drain system (DigiVent™), in patients undergoing lung resection (sutures and/or staples alone). Methods Patients who intraoperatively showed moderate o...

  9. Simulation study of huff-n-puff air injection for enhanced oil recovery in shale oil reservoirs

    Directory of Open Access Journals (Sweden)

    Hu Jia

    2018-03-01

    Full Text Available This paper is the first attempt to evaluate huff-n-puff air injection in a shale oil reservoir using a simulation approach. Recovery mechanisms and physical processes of huff-n-puff air injection in a shale oil reservoir are investigated through investigating production performance, thermal behavior, reservoir pressure and fluid saturation features. Air flooding is used as the basic case for a comparative study. The simulation study suggests that thermal drive is the main recovery mechanism for huff-n-puff air injection in the shale oil reservoir, but not for simple air flooding. The synergic recovery mechanism of air flooding in conventional light oil reservoirs can be replicated in shale oil reservoirs by using air huff-n-puff injection strategy. Reducing huff-n-puff time is better for performing the synergic recovery mechanism of air injection. O2 diffusion plays an important role in huff-n-puff air injection in shale oil reservoirs. Pressure transmissibility as well as reservoir pressure maintenance ability in huff-n-puff air injection is more pronounced than the simple air flooding after primary depletion stage. No obvious gas override is exhibited in both air flooding and air huff-n-puff injection scenarios in shale reservoirs. Huff-n-puff air injection has great potential to develop shale oil reservoirs. The results from this work may stimulate further investigations.

  10. Linking Meteorology, Air Quality Models and Observations to Characterize Human Exposures in Support of the Environmental Health Studies

    Science.gov (United States)

    Epidemiologic studies are critical in establishing the association between exposure to air pollutants and adverse health effects. Results of epidemiologic studies are used by U.S. EPA in developing air quality standards to protect the public from the health effects of air polluta...

  11. Harvard Air Pollution Health Study in six cites in the USA

    Energy Technology Data Exchange (ETDEWEB)

    Spengler, J D; Ferris, Jr, B G

    1985-08-01

    The Harvard Air Pollution Health Study has been a ten year prospective study of respiratory symptoms and pulmonary function of children and adults living in six US communities. Indices of acute and chronic effects of air pollution exposures have been studied. Evidence is presented for adverse effects of ambient and indoor air pollution on children. Relationships between ambient TSP concentrations and hospital emergency room admissions, temporary decreases in pulmonary functions and prevalence of community bronchitis all indicate a slight adverse effect. Refinements of these relationships will occur when fine fraction and acid sulfate aerosol concentrations are incorporated into the health analysis. Exposures to cigarette smoke at home are associated with increased reported respiratory symptoms in children. There is a negative relationship between maternal smoking and age and sex adjusted height for children. Results from indoor and personal exposure studies have lead to the design of an acute symptoms and indoor air pollution study. Between 1985 and 1988 1800 children will be tracked for a year while respirable particles, nitrogen dioxide, water vapor and air exchange will be measured in their homes. Using continuous sulfate/sulfuric acid monitors built at Harvard, we are characterizing the magnitude, duration and frequency of acid aerosol events in each of our study cities. This information will be utilized in the analysis of the respiratory symptom data. The Harvard Air Pollution Health Study is providing information on the relationship among health variables and air pollutant exposures. In addition, this study will add to our understanding of lung growth and aging and the risk factors associated with chronic respiratory disabilities.

  12. Modelling studies for influence factors of gas bubble in compressed air energy storage in aquifers

    International Nuclear Information System (INIS)

    Guo, Chaobin; Zhang, Keni; Li, Cai; Wang, Xiaoyu

    2016-01-01

    CAES (Compressed air energy storage) is credited with its potential ability for large-scale energy storage. Generally, it is more convenient using deep aquifers than employing underground caverns for energy storage, because of extensive presence of aquifers. During the first stage in a typical process of CAESA (compressed air energy storage in aquifers), a large amount of compressed air is injected into the target aquifer to develop an initial space (a gas bubble) for energy storage. In this study, numerical simulations were conducted to investigate the influence of aquifer's permeability, geological structure and operation parameters on the formation of gas bubble and the sustainability for the later cycling operation. The SCT (system cycle times) was designed as a parameter to evaluate the reservoir performance and the effect of operation parameters. Simulation results for pressure and gas saturation results of basic model confirm the feasibility of compressed air energy storage in aquifers. The results of different permeability cases show that, for a certain scale of CAESA system, there is an optimum permeability range for a candidate aquifer. An aquifer within this permeability range will not only satisfy the injectivity requirement but also have the best energy efficiency. Structural impact analysis indicates that the anticline structure has the best performance to hold the bubble under the same daily cycling schedule with the same initial injected air mass. In addition, our results indicate that the SCT shows a logarithmic growth as the injected air mass increase. During the formation of gas bubble, compressed air should be injected into aquifers with moderate rate and the injection can be done in several stages with different injection rate to avoid onset pressure. - Highlights: • Impact of permeability, geological structure, operation parameters was investigated. • With certain air production rate, an optimum permeability exists for performance.

  13. Atlanta Rail Yard Study: Evaluation of local-scale air pollution ...

    Science.gov (United States)

    Intermodal rail yards are important nodes in the freight transportation network, where freight is organized and moved from one mode of transport to another, critical equipment is serviced, and freight is routed to its next destination. Rail yard environments are also areas with multiple sources of air pollutant emissions (e.g., heavy-duty vehicles, locomotives, cranes), which may affect local air quality in residential areas nearby. In order to understand emissions and related air quality impacts, two field studies took place over the time span of 2010-2012 to measure air pollution trends in close proximity to the Inman and Tilford rail yard complex in Atlanta, GA. One field study involved long-term stationary monitoring of black carbon, fine particles, and carbon dioxide at two stations nearby the rail yard. In addition, a second field study performed intensive mobile air monitoring for a one month period in the summer of 2012 at a roadway network surrounding the rail yard complex and measured a comprehensive array of pollutants. Real-time mobile particulate measurements included particle counts, extinction coefficient, black carbon via light-absorption and particle incandescence, and particle composition derived by aerosol mass spectrometry. Gas-phase measurements included oxides of nitrogen, sulfur dioxide, carbon dioxide, and air toxics (e.g., benzene). Both sets of measurements determined detectable local influence from rail yard-related emissions.

  14. Air pollution and case fatality of SARS in the People's Republic of China: an ecologic study

    Directory of Open Access Journals (Sweden)

    Yu Shun-Zhang

    2003-11-01

    Full Text Available Abstract Background Severe acute respiratory syndrome (SARS has claimed 349 lives with 5,327 probable cases reported in mainland China since November 2002. SARS case fatality has varied across geographical areas, which might be partially explained by air pollution level. Methods Publicly accessible data on SARS morbidity and mortality were utilized in the data analysis. Air pollution was evaluated by air pollution index (API derived from the concentrations of particulate matter, sulfur dioxide, nitrogen dioxide, carbon monoxide and ground-level ozone. Ecologic analysis was conducted to explore the association and correlation between air pollution and SARS case fatality via model fitting. Partially ecologic studies were performed to assess the effects of long-term and short-term exposures on the risk of dying from SARS. Results Ecologic analysis conducted among 5 regions with 100 or more SARS cases showed that case fatality rate increased with the increment of API (case fatality = - 0.063 + 0.001 * API. Partially ecologic study based on short-term exposure demonstrated that SARS patients from regions with moderate APIs had an 84% increased risk of dying from SARS compared to those from regions with low APIs (RR = 1.84, 95% CI: 1.41–2.40. Similarly, SARS patients from regions with high APIs were twice as likely to die from SARS compared to those from regions with low APIs. (RR = 2.18, 95% CI: 1.31–3.65. Partially ecologic analysis based on long-term exposure to ambient air pollution showed the similar association. Conclusion Our studies demonstrated a positive association between air pollution and SARS case fatality in Chinese population by utilizing publicly accessible data on SARS statistics and air pollution indices. Although ecologic fallacy and uncontrolled confounding effect might have biased the results, the possibility of a detrimental effect of air pollution on the prognosis of SARS patients deserves further investigation.

  15. Studying the fate of non-volatile organic compounds in a commercial plasma air purifier

    Energy Technology Data Exchange (ETDEWEB)

    Schmid, Stefan [ETH Zürich, Department of Chemistry and Applied Biosciences, CH-8093 Zürich (Switzerland); Seiler, Cornelia; Gerecke, Andreas C. [Swiss Federal Laboratories for Material Science and Technology (EMPA), CH-8600 Dübendorf (Switzerland); Hächler, Herbert [University of Zürich, Institute for Food Safety and Hygiene, National Centre for Enteropathogenic Bacteria and Listeria (NENT), CH-8057 Zürich (Switzerland); Hilbi, Hubert [Ludwig-Maximilians-Universität München Max von Pettenkofer-Institut, D-80336 München (Germany); Frey, Joachim [University of Bern, Institute for Veterinary Bacteriology, CH-3001 Bern (Switzerland); Weidmann, Simon; Meier, Lukas; Berchtold, Christian [ETH Zürich, Department of Chemistry and Applied Biosciences, CH-8093 Zürich (Switzerland); Zenobi, Renato, E-mail: zenobi@org.chem.ethz.ch [ETH Zürich, Department of Chemistry and Applied Biosciences, CH-8093 Zürich (Switzerland)

    2013-07-15

    Highlights: • Degradation of environmental toxins, a protein, and bioparticles were studied. • A commercial air purifier based on a cold plasma was used. • Passage through the device reduced the concentration of the compounds/particles. • Deposition inside the plasma air purifier was the main removal process. -- Abstract: Degradation of non-volatile organic compounds–environmental toxins (methyltriclosane and phenanthrene), bovine serum albumin, as well as bioparticles (Legionella pneumophila, Bacillus subtilis, and Bacillus anthracis)–in a commercially available plasma air purifier based on a cold plasma was studied in detail, focusing on its efficiency and on the resulting degradation products. This system is capable of handling air flow velocities of up to 3.0 m s{sup −1} (3200 L min{sup −1}), much higher than other plasma-based reactors described in the literature, which generally are limited to air flow rates below 10 L min{sup −1}. Mass balance studies consistently indicated a reduction in concentration of the compounds/particles after passage through the plasma air purifier, 31% for phenanthrene, 17% for methyltriclosane, and 80% for bovine serum albumin. L. pneumophila did not survive passage through the plasma air purifier, and cell counts of aerosolized spores of B. subtilis and B. anthracis were reduced by 26- and 15-fold, depending on whether it was run at 10 Hz or 50 Hz, respectively. However rather than chemical degradation, deposition on the inner surfaces of the plasma air purifier occured. Our interpretation is that putative “degradation” efficiencies were largely due to electrostatic precipitation rather than to decomposition into smaller molecules.

  16. Radioactivity measurements of soil samples in the Republic of Serbia for the period 1999-2001

    International Nuclear Information System (INIS)

    Eremic Savkovic, M.; Pantelic, G.; Javorina, L.; Tanaskovic, I.; Vuletic, V.

    2002-01-01

    The soil is the basic environment of migration of radionuclides into plants, from which they reach the people and animals through food. The type of soil affects the distribution of radionuclides in the soil itself and their transfer into plants, respectively. Systemic testing of radioactivity of soils is performed on specific locations in the Federal Republic of Yugoslavia, in particular time periods according to methods defined by regulations. As result of NATO aggression and use of ammunition with depleted uranium in 1999, the existing radioactivity monitoring program of Yugoslavia was modified. Besides measurement of activity of artificial radionuclides, that were present in living environment after Chernobyl accident in 1986, the testing of activity of natural radionuclides, especially of uranium, was carried out as well. Uranium in Serbia derives from natural sources, considering the geological composition of rocks and geochemical composition of soil, and their concentrations as well as the concentrations of its descendants represent the significant component of natural sources of ionizing irradiation. In Serbia, the major uranium sources are igneous, carbonic and sedimentary rocks, and granite. According to perennial geological investigation of uranium in our country, several geological regions have been found to have uranium in higher or lower concentration. The uranium concentration in these regions ranged from 0.003g/t for ultra basic rocks to 3.5g/t for igneous, sedimentary rocks and granite. One of considerable uranium sources is specific technological procedure in industry such as production and combustion of coal in thermal plants, production of phosphate mineral fertilizers, production of phosphoric acid, phosphoric plaster, etc

  17. Campaign 1999-2001 of radon measurement in the establishments receiving public

    International Nuclear Information System (INIS)

    2001-11-01

    After some elements of context on the radon measurement in France, and a presentation of realised actions in 2001 by the Ministry in charge of health to manage the radon risk, this document exposes a synthesis in three parts on the situation of radon measurement campaigns in the establishments receiving public. The first part gives the methodology followed to make this state, the second part presents the synthetic results by department, and the last one the results at the regional level. (N.C.)

  18. SAFARI 2000 TOVS Surface and Atmospheric Parameters, 1-Deg, 1999-2001

    Data.gov (United States)

    National Aeronautics and Space Administration — ABSTRACT: NOAA's TIROS (Television Infrared Observation Satellite) Operational Vertical Sounder (TOVS) is a suite of three sensors: the Microwave Sounding Unit...

  19. [Statistical analysis of the incidence of some cancers in the province of Taranto 1999-2001].

    Science.gov (United States)

    Graziano, Giusi; Bilancia, Massimo; Bisceglia, Lucia; de Nichilo, Gigliola; Pollice, Alessio; Assennato, Giorgio

    2009-01-01

    to estimate the spatial distribution of risk, in order to assess its correlation to environmental pollution exposure around the large production facilities located in the Taranto area, and to identify high risk areas not previously reported. Italy, Taranto province (581,508 inhabitants). incidence data in 29 municipalities of the Taranto province were extracted from the Jonico Salentino Cancer Registry (RTJS) for the following cancer sites: lung (ICDX C33-C34); pleura, pleuric mesothelioma (ICDX C45.0); bladder, malignancies only (ICDX C67); brain (ICDX C70-72); non-Hodgkin lymphoma (ICDX C82-85, C96); leukaemia (ICDX C91-5). Age standardized incidence rates for the whole province were computed. High-level risk areas were classified using a Poisson model, computing area-specific p-values associated to the null hypothesis of no increased risk (i.e. relative risk equal to 1). A hierarchical spatial Bayesian model was estimated to strengthen results: specifically two additional variance components, accounting for relative risk spatial autocorrelation and excess heterogeneity respectively, were considered in the model specification. Bayesian mapping of disease incidence allows for the drawing of regularized (smoothed) maps. To adjust for the effect of socio-economic deprivation, a five-variable index was introduced into the model as an ecological covariate. an increased risk of lung, pleura and bladder cancer was observed among male residents in the city of Taranto (respectively: SIR 1.24, p-value sexe risk (especially among males) of lung, pleura and bladder cancer is likely related to the chemical pollutants and asbestos, due to the presence of many industries and shipyards in the city of Taranto.

  20. SAFARI 2000 FEWS 10-day Rainfall Estimate, 8-Km, 1999-2001

    Data.gov (United States)

    National Aeronautics and Space Administration — ABSTRACT: The U.S. Agency for International Development (USAID) Famine Early Warning System (FEWS) has been supporting the production of 10-day Rainfall Estimate...

  1. LBA-ECO ND-02 Trace Gas Flux from Forest Soil, Para, Brazil : 1999-2001

    Data.gov (United States)

    National Aeronautics and Space Administration — This data set contains soil emissions of nitric oxide (NO), carbon dioxide (CO2), nitrous oxide (N2O), and methane (CH4) measured in plots of a secondary-growth...

  2. LBA-ECO ND-02 Trace Gas Flux from Forest Soil, Para, Brazil : 1999-2001

    Data.gov (United States)

    National Aeronautics and Space Administration — ABSTRACT: This data set contains soil emissions of nitric oxide (NO), carbon dioxide (CO2), nitrous oxide (N2O), and methane (CH4) measured in plots of a...

  3. Arctic Sea Ice Melt Pond Statistics and Maps, 1999-2001

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Visible band imagery from high-resolution satellites were acquired over four Arctic Ocean sites (three in 1999) during the summers of 1999, 2000, and 2001. The sites...

  4. Kailua Bay, Oahu, Hawaii benthic mapping data for 1999-2001 (NODC Accession 0001239)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Benthic mapping surveys were conducted from March 1999 to January 2001 aperiodically in support of research related to sedimentology, sea level history, and reef...

  5. SAFARI 2000 TOVS Surface and Atmospheric Parameters, 1-Deg, 1999-2001

    Data.gov (United States)

    National Aeronautics and Space Administration — NOAA's TIROS (Television Infrared Observation Satellite) Operational Vertical Sounder (TOVS) is a suite of three sensors: the Microwave Sounding Unit (MSU), the High...

  6. Monitoring the hygene of chicken hatcheries in Taiwan during 1999-2001.

    Science.gov (United States)

    Chen, Su-Jen; Lee, Tsui-Er; Wang, Eve-Ming; Cho, Ta-Jen; Wang, Ching-Ho

    2002-12-01

    Microorganism contamination in hatcheries and eggs has a serious impact on the viability and quality of chicks as well as on the overall growth performance of chickens. Microbiological agents are present in the fluff when chicks hatch. Detecting microorganisms in fluff is a convenient method for evaluating the hygienic status in a hatchery. Fluff samples from 31 hatcheries collected over 3 years were tested for the total bacterial count, the presence of Salmonella spp., and fungus to evaluate the hygienic status of hatcheries in Taiwan from 1999 through 2001. The total bacterial score from the fluff samples was calculated and expressed as a bacterial score in a log scale. Most hatcheries had a bacterial count ranged from scale 1 to 3. Among the hatcheries, 13% to 29% were contaminated with Salmonella spp.; and 33% to 73% were contaminated with fungi in different quarters. The third quarter of each year was the most contaminated period (phatcheries keep their hygienic status and supply good quality chicks by cleaning and disinfecting.

  7. Study on heat transfer from hot water to air with evaporation. 2nd report

    International Nuclear Information System (INIS)

    Yamaji, Tatsuya; Hirota, Tatsuya; Koizumi, Yasuo; Murase, Michio

    2013-01-01

    Heat transfer from hot water flow to cold air flow was examined. In the present study, the air flow was in turbulent flow condition. When the heat flux from the water flow to the air flow is divides into two terms of an evaporation term and a convection term, the evaporation term is much higher than the convection term; approximately 80 ∼ 60% of the total heat flux since latent heat is taken into the air flow by evaporating vapor. The convection term was approximately two times of the single-phase heat transfer rate with no evaporation. By making use of the analogy between the mass transfer and the heat transfer, and the single-phase heat transfer correlation, the predicting method of the heat transfer rate with the evaporation was developed. (author)

  8. Neurotoxicants Are in the Air: Convergence of Human, Animal, and In Vitro Studies on the Effects of Air Pollution on the Brain

    Directory of Open Access Journals (Sweden)

    Lucio G. Costa

    2014-01-01

    Full Text Available In addition to increased morbidity and mortality caused by respiratory and cardiovascular diseases, air pollution may also negatively affect the brain and contribute to central nervous system diseases. Air pollution is a mixture comprised of several components, of which ultrafine particulate matter (UFPM; <100 nm is of much concern, as these particles can enter the circulation and distribute to most organs, including the brain. A major constituent of ambient UFPM is represented by traffic-related air pollution, mostly ascribed to diesel exhaust (DE. Human epidemiological studies and controlled animal studies have shown that exposure to air pollution may lead to neurotoxicity. In addition to a variety of behavioral abnormalities, two prominent effects caused by air pollution are oxidative stress and neuroinflammation, which are seen in both humans and animals and are confirmed by in vitro studies. Among factors which can affect neurotoxic outcomes, age is considered the most relevant. Human and animal studies suggest that air pollution (and DE may cause developmental neurotoxicity and may contribute to the etiology of neurodevelopmental disorders, including autistic spectrum disorders. In addition, air pollution exposure has been associated with increased expression of markers of neurodegenerative disease pathologies.

  9. COLONOSCOPY: RANDOMIZED COMPARATIVE STUDY OF INSUFFLATION WITH CARBON DIOXIDE VERSUS AIR

    Science.gov (United States)

    DE-QUADROS, Luiz Gustavo; KAISER-JÚNIOR, Roberto Luiz; FELIX, Valter Nilton; VILLAR, Lucio; CAMPOS, Josemberg Marins; NOGUEIRA, Vinicius Quintiliano Moutinho; TEIXEIRA, André; ZOTARELLI-FILHO, Idiberto José

    2017-01-01

    ABSTRACT Background: In Brazil, an increasing number of people are submitted to colonoscopy, either for screening or for therapeutic purposes. Aim: To evaluate whether there are advantages of using carbon dioxide (CO2) over air for insufflation. Methods: Two hundred and ten of 219 patients were considered eligible for this study and were randomized into two groups according to the gas insufflation used: Air Group (n=104) and CO2 Group (n=97). The study employed a double-blind design. Results: The Air and CO2 Groups were similar in respect to bowel preparation evaluated using the Boston scale, age, gender, previous surgery, maneuvers necessary for the advancement of the device, and presence of polyps, tumors or signs of diverticulitis. However, “waking up with pain” and “pain at discharge” were more prevalent in the Air Group, albeit not statistically significant, with post-exam bloating seen only in the Air Group. The responses to a questionnaire, applied to analyze the late post-exam period, showed more comfort with the use of CO2. Conclusions: The use of CO2 is better than air as it avoids post-examination bloating, thereby providing greater comfort to patients. PMID:29019557

  10. Study, Evaluation and Implementation of Improvement in a Compressed Air Plant

    Directory of Open Access Journals (Sweden)

    Carlos Roberto Altafini

    2013-12-01

    Full Text Available This paper presents a study of a compressed air generation system in a bus manufacturer, being evaluated the operation of the compressors to identify the electric energy consumption. A maintenance plan is elaborated to correct the air system leaks and also proposes the reuse of thermal energy generated by the compressors. Initially, as for the purpose of this paper, a revision of fundamentals related to thermodynamics transformation is presented. Afterwards, some important electric energy concepts will lead to the understanding of the energy consumption of the compressors. Then, an overview about compressed air generation systems will be showed with the goal of understanding techniques of energetic efficiency. The tools used in this study for collecting data were the software of a compressor manufacturer with pressure transducers and an energy analyzer. The basic concepts and their uses will be shown along this paper. The proposal of electric energy consumption reduction was achieved with the installation of compressor operation managers and yields a reduction about 60,600 kWh per month, which provided a monthly saving of R$19,400.00, validating the collected data. For heat recovery from the cooling air compressors, externally finned coils were sized to heat water up to 55◦C and used in a process of heating rubber gaskets. For air leakage reduction, a working methodology to perform the corrective and preventive maintenance has been prepared, and a control system in the form of internal audit. The obtained air leakage reduction was about 50%.

  11. Determinants of perceived air pollution annoyance and association between annoyance scores and air pollution (PM 2.5, NO 2) concentrations in the European EXPOLIS study

    Science.gov (United States)

    Rotko, Tuulia; Oglesby, Lucy; Künzli, Nino; Carrer, Paolo; Nieuwenhuijsen, Mark J.; Jantunen, Matti

    Apart from its traditionally considered objective impacts on health, air pollution can also have perceived effects, such as annoyance. The psychological effects of air pollution may often be more important to well-being than the biophysical effects. Health effects of perceived annoyance from air pollution are so far unknown. More knowledge of air pollution annoyance levels, determinants and also associations with different air pollution components is needed. In the European air pollution exposure study, EXPOLIS, the air pollution annoyance as perceived at home, workplace and in traffic were surveyed among other study objectives. Overall 1736 randomly drawn 25-55-yr-old subjects participated in six cities (Athens, Basel, Milan, Oxford, Prague and Helsinki). Levels and predictors of individual perceived annoyances from air pollution were assessed. Instead of the usual air pollution concentrations at fixed monitoring sites, this paper compares the measured microenvironment concentrations and personal exposures of PM 2.5 and NO 2 to the perceived annoyance levels. A considerable proportion of the adults surveyed was annoyed by air pollution. Female gender, self-reported respiratory symptoms, downtown living and self-reported sensitivity to air pollution were directly associated with high air pollution annoyance score while in traffic, but smoking status, age or education level were not significantly associated. Population level annoyance averages correlated with the city average exposure levels of PM 2.5 and NO 2. A high correlation was observed between the personal 48-h PM 2.5 exposure and perceived annoyance at home as well as between the mean annoyance at work and both the average work indoor PM 2.5 and the personal work time PM 2.5 exposure. With the other significant determinants (gender, city code, home location) and home outdoor levels the model explained 14% (PM 2.5) and 19% (NO 2) of the variation in perceived air pollution annoyance in traffic. Compared to

  12. Kriged and modeled ambient air levels of benzene in an urban environment: an exposure assessment study

    Directory of Open Access Journals (Sweden)

    Lai Dejian

    2011-03-01

    Full Text Available Abstract Background There is increasing concern regarding the potential adverse health effects of air pollution, particularly hazardous air pollutants (HAPs. However, quantifying exposure to these pollutants is problematic. Objective Our goal was to explore the utility of kriging, a spatial interpolation method, for exposure assessment in epidemiologic studies of HAPs. We used benzene as an example and compared census tract-level kriged predictions to estimates obtained from the 1999 U.S. EPA National Air Toxics Assessment (NATA, Assessment System for Population Exposure Nationwide (ASPEN model. Methods Kriged predictions were generated for 649 census tracts in Harris County, Texas using estimates of annual benzene air concentrations from 17 monitoring sites operating in Harris and surrounding counties from 1998 to 2000. Year 1999 ASPEN modeled estimates were also obtained for each census tract. Spearman rank correlation analyses were performed on the modeled and kriged benzene levels. Weighted kappa statistics were computed to assess agreement between discretized kriged and modeled estimates of ambient air levels of benzene. Results There was modest correlation between the predicted and modeled values across census tracts. Overall, 56.2%, 40.7%, 31.5% and 28.2% of census tracts were classified as having 'low', 'medium-low', 'medium-high' and 'high' ambient air levels of benzene, respectively, comparing predicted and modeled benzene levels. The weighted kappa statistic was 0.26 (95% confidence interval (CI = 0.20, 0.31, indicating poor agreement between the two methods. Conclusions There was a lack of concordance between predicted and modeled ambient air levels of benzene. Applying methods of spatial interpolation for assessing exposure to ambient air pollutants in health effect studies is hindered by the placement and number of existing stationary monitors collecting HAP data. Routine monitoring needs to be expanded if we are to use these data

  13. A study of air-operated valves in U.S. nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Rothberg, O. [Idaho National Engineering and Environmental Laboratory, Idaho Falls, ID (United States); Khericha, S. [Idaho National Engineering and Environmental Laboratory, Idaho Falls, ID (United States); Watkins, J. [Idaho National Engineering and Environmental Laboratory, Idaho Falls, ID (United States); Holbrook, M. [Idaho National Engineering and Environmental Laboratory, Idaho Falls, ID (United States)

    2000-02-01

    A study of air-operated valves in nuclear power plant applications was conducted for the NRC Office of Research (the project was initiated by NRC/AEOD). The results of the study were based on visits to seven nuclear power plant sites, literature studies, and examinations of event records in databases available to the NRC. The purpose is to provide information to the NRC staff concerning capabilities and performance of air-operated valves (AOVs). Descriptions of air systems and AOVs were studied along with the support systems and equipment. Systems and equipment that contain AOVs and SOVs were studied to determine their dependencies. Applications of AOVs and SOVs were listed along with current NRC requirements.

  14. A study of air-operated valves in U.S. nuclear power plants

    International Nuclear Information System (INIS)

    Rothberg, O.; Khericha, S.; Watkins, J.; Holbrook, M.

    2000-01-01

    A study of air-operated valves in nuclear power plant applications was conducted for the NRC Office of Research (the project was initiated by NRC/AEOD). The results of the study were based on visits to seven nuclear power plant sites, literature studies, and examinations of event records in databases available to the NRC. The purpose is to provide information to the NRC staff concerning capabilities and performance of air-operated valves (AOVs). Descriptions of air systems and AOVs were studied along with the support systems and equipment. Systems and equipment that contain AOVs and SOVs were studied to determine their dependencies. Applications of AOVs and SOVs were listed along with current NRC requirements.

  15. Particulate matter concentrations in residences: an intervention study evaluating stand-alone filters and air conditioners.

    Science.gov (United States)

    Batterman, S; Du, L; Mentz, G; Mukherjee, B; Parker, E; Godwin, C; Chin, J-Y; O'Toole, A; Robins, T; Rowe, Z; Lewis, T

    2012-06-01

    This study, a randomized controlled trial, evaluated the effectiveness of free-standing air filters and window air conditioners (ACs) in 126 low-income households of children with asthma. Households were randomized into a control group, a group receiving a free-standing HEPA filter placed in the child's sleeping area, and a group receiving the filter and a window-mounted AC. Indoor air quality (IAQ) was monitored for week-long periods over three to four seasons. High concentrations of particulate matter (PM) and carbon dioxide were frequently seen. When IAQ was monitored, filters reduced PM levels in the child's bedroom by an average of 50%. Filter use varied greatly among households and declined over time, for example, during weeks when pollutants were monitored, filter use was initially high, averaging 84±27%, but dropped to 63±33% in subsequent seasons. In months when households were not visited, use averaged only 34±30%. Filter effectiveness did not vary in homes with central or room ACs. The study shows that measurements over multiple seasons are needed to characterize air quality and filter performance. The effectiveness of interventions using free-standing air filters depends on occupant behavior, and strategies to ensure filter use should be an integral part of interventions. Environmental tobacco smoke (ETS) increased particulate matter (PM) levels by about 14 μg/m3 and was often detected using ETS-specific tracers despite restrictions on smoking in the house as reported on questionnaires administered to caregivers. PM concentrations depended on season, filter usage, relative humidity, air exchange ratios, number of children, outdoor PM levels, sweeping/dusting, and presence of a central air conditioner (AC). Free-standing air filters can be an effective intervention that provides substantial reductions in PM concentrations if the filters are used. However, filter use was variable across the study population and declined over the study duration, and

  16. Acute symptoms related to air pollution in urban areas: a study protocol

    Directory of Open Access Journals (Sweden)

    Forouzanfar Mohammad

    2006-08-01

    Full Text Available Abstract Background The harmful effects of urban air pollution on general population in terms of annoying symptoms are not adequately evaluated. This is in contrast to the hospital admissions and short term mortality. The present study protocol is designed to assess the association between the level of exposure to certain ambient air pollutants and a wide range of relevant symptoms. Awareness of the impact of pollution on the population at large will make our estimates of the pertinent covert burden imposed on the society more accurate. Methods/design A cross sectional study with spatial analysis for the addresses of the participants was conducted. Data were collected via telephone interviews administered to a representative sample of civilians over age four in the city. Households were selected using random digit dialling procedures and randomization within each household was also performed to select the person to be interviewed. Levels of exposure are quantified by extrapolating the addresses of the study population over the air pollution matrix of the city at the time of the interview and also for different lag times. This information system uses the data from multiple air pollution monitoring stations in conjunction with meteorological data. General linear models are applied for statistical analysis. Discussion The important limitations of cross-sectional studies on acute effects of air pollution are personal confounders and measurement error for exposure. A wide range of confounders in this study are controlled for in the statistical analysis. Exposure error may be minimised by employing a validated geographical information system that provides accurate estimates and getting detailed information on locations of individual participants during the day. The widespread operation of open air conditioning systems in the target urban area which brings about excellent mixing of the outdoor and indoor air increases the validity of outdoor pollutants

  17. Experimental study of air distribution and ventilation effectiveness in a room heated by warm air and/or floor heating

    DEFF Research Database (Denmark)

    Simone, Angela; Olesen, Bjarne W.; Krajčík, Michal

    2010-01-01

    The levels of required ventilation depend on the criteria for indoor air quality in existing standards and guidelines. On top of that, the resulting ventilation in air changes per hour is depending on the ventilation effectiveness. In the standard CR 1752 the recommended values for ventilation ef...

  18. Air Pollution Awareness in the Scope of the Community Service Practices Course: An Interdisciplinary Study

    Science.gov (United States)

    Aydin-Güç, Funda; Aygün, Müge; Ceylan, Derya; Çavus-Güngören, Seda; Durukan, Ümmü Gülsüm; Hacioglu, Yasemin; Yekeler, Ayse Dilek

    2018-01-01

    The aim of this study is to determine the effect of the interdisciplinary (the disciplines of Turkish, Social Science, Natural Sciences, Mathematics and Public Administration) activities performed in the scope of the Community Service Practices Course on the air pollution awareness (APW). This study has been performed as a multiple case study.…

  19. Air Pollution and Mortality in Seven Million Adults : The Dutch Environmental Longitudinal Study (DUELS)

    NARCIS (Netherlands)

    Fischer, Paul H; Marra, Marten; Ameling, Caroline B; Hoek, Gerard|info:eu-repo/dai/nl/069553475; Beelen, Rob|info:eu-repo/dai/nl/30483100X; de Hoogh, Kees; Breugelmans, Oscar; Kruize, Hanneke; Janssen, Nicole A H; Houthuijs, Danny

    BACKGROUND: Long-term exposure to air pollution has been associated with mortality in urban cohort studies. Few studies have investigated this association in large-scale population registries, including non-urban populations. OBJECTIVES: The aim of the study was to evaluate the associations between

  20. Validation of traffic-related air pollution exposure estimates for long-term studies

    NARCIS (Netherlands)

    Van Roosbroeck, S.

    2007-01-01

    This thesis describes a series of studies that investigate the validity of using outdoor concentrations and/or traffic-related indicator exposure variables as a measure for exposure assessment in epidemiological studies on the long-term effect of traffic-related air pollution. A pilot study was

  1. Why participation matters for air quality studies: risk perceptions, understandings of air pollution and mobilization in a poor neighborhood in Nairobi, Kenya.

    Science.gov (United States)

    Ngo, N S; Kokoyo, S; Klopp, J

    2017-01-01

    With high urbanization rates, Sub-Saharan Africa is facing growing problems of poor air quality in its cities. We make a case for participatory approaches in air quality studies especially including those living in poor neighborhoods who may be particularly at risk from this trend. We used collaboration with a community based organization, interviews, focus group discussions and a community forum. We conducted a pilot study to assess health risk perceptions of air pollution for civic-minded residents in Mathare, an informal settlement in Nairobi, Kenya. Simultaneously, we involved Mathare residents in measuring levels of PM 2.5 and later presented these data at a community forum with the participants of the monitoring study and the focus group discussions. We found that participation in conducting and interpreting air quality studies helped residents improve their understanding of air pollution and also helped them develop responses to it. Initially, participants associated air pollution with a bad odor or discomfort rather than their health, but once the connection to health was made through participation, they sought more information about air quality data and its hazards. Some residents also came up with strategies for coping with their environment and its risks. These results point to the potential of including participation in air quality monitoring as a way to increase awareness and support local action to address it. Discussion and sharing of results at the local level as well as at a wider policy level will be critical for advocacy to improve air quality. Copyright © 2015 The Royal Society for Public Health. Published by Elsevier Ltd. All rights reserved.

  2. A study on the air pollution related human diseases in Thiruvananthapuram City, Kerala

    Energy Technology Data Exchange (ETDEWEB)

    Bency, K.T.; Jansy, J.; Thakappan, B.; Kumar, B.; Sreelekha, T.T.; Hareendran, N.K.; Nair, P.K.K.; Krishnan Nair, M. [National Inst. of Environmental Health, Thiruvananthapuram, Kerala (India). Regional Cancer Centre

    2005-07-01

    This paper contains the results of a study that examined the impacts of air pollution on human health in Thiruvananthapuram City, India. The study compared health impacts arising from air pollution in three different zones including residential, commercial, and industrial. The paper presents the findings from the study according to each of these zones and presents conclusions.The study found that each zone had its individual environmental problems which were characterized by specific diseases. In the residential zone, there was a prevalence of diseases such as breast cancer and cardiac-related problems as well as dietary problems linked to obesity. In the industrial zone, respiratory illnesses related to air pollution were prevalent. Cardiac and vector-borne diseases, related to environmental hazards like waste water stagnation, dust and solid waste problem, were high in the commercial zone. 14 refs., 3 figs.

  3. Traffic-related air pollution, preterm birth and term birth weight in the PIAMA birth cohort study

    NARCIS (Netherlands)

    Gehring, Ulrike; Wijga, Alet H.; Fischer, Paul; de Jongste, Johan C.; Kerkhof, Marjan; Koppelman, Gerard H.; Smit, Henriette A.; Brunekreef, Bert

    Background: Maternal exposure to air pollution has been associated with adverse pregnancy outcomes. Few studies took into account the spatial and temporal variation of air pollution levels. Objectives: To evaluate the impact of maternal exposure to traffic-related air pollution during pregnancy on

  4. Experimental study of a combined system of solar Kang and solar air collector

    International Nuclear Information System (INIS)

    Wei, Wei; Ji, Jie; Chow, Tin-Tai; He, Wei; Chen, Haifei; Guo, Chao; Yu, Hancheng

    2015-01-01

    Highlights: • A combined system of solar Kang and solar air collector is proposed. • An experimental study on the combined system is made. • The mean air temperature reaches 18.5 °C and maintains above 18 °C for 13 h. • The corresponding mean indoor air temperature of the reference room is 8.9 °C. • The Kang surface temperature reaches 27 °C and maintains above 18 °C for 23 h. - Abstract: Chinese Kang is widely used as heated bed and for heat recovery of cooking stove in Northern China. However there are main drawbacks of indoor and outdoor air pollutant generation and heavy demands on solid fuel handling. A novel combined Kang system, which integrates solar Kang and solar air collector, is here proposed. Experiments were conducted to examine the alternative operating modes: (i) only solar air collector in service, (ii) only solar Kang in service, and (iii) both solar Kang and solar air collector in service. The results show that these three modes behave differently and have distinct effects on room thermal environment in winter. When this pollution-free system operates under the third combined mode, the room temperature increases significantly and the vertical temperature gradient reduces. The Kang surface temperature increases and its uniformity is improved. It is also found that the room air temperature is closely related to the Kang surface temperature. Furthermore, most of the time the thermal environment meets the occupant need. This paper reports the experimental work and investigates into the effects on indoor thermal environment as in rural residences in Northern China

  5. An experimental study of the exergetic performance of an underground air tunnel system for greenhouse cooling

    International Nuclear Information System (INIS)

    Ozgener, Leyla; Ozgener, Onder

    2010-01-01

    The present study highlights the exergetic performance characteristics of an underground air tunnel for greenhouse cooling with a 47 m horizontal, 56 cm nominal diameter U-bend buried galvanized ground heat exchanger. This system was designed and installed in the Solar Energy Institute, Ege University, Izmir, Turkey. Underground air tunnel systems, also known as earth-to-air heat exchangers, are recognized to be outstanding heating, cooling and air heating systems. On the other hand, they have not been used yet in the Turkish market. Greenhouses also have important economical potential in Turkey's agricultural sector. Greenhouses should be cooled during the summer or hot days. In order to establish optimum growth conditions in greenhouses, renewable energy sources should be utilized as much as possible. It is expected that effective use of underground air tunnels with a suitable technology in the modern greenhouses will play a leading role in Turkey in the foreseeable future. The exergy transports between the components and the destructions in each of the components of the system are determined for the average measured parameters obtained from the experimental results. Exergetic efficiencies of the system components are determined in an attempt to assess their individual performances and the potential for improvements is also presented. The daily maximum cooling coefficient of performances (COP) values for the system are also obtained to be 15.8. The total average COP in the experimental period is found to be 10.09. The system COP was calculated based on the amount of cooling produced by the air tunnel and the amount of power required to move the air through the tunnel, while the exergetic efficiency of the air tunnel is found to be in a range among 57.8-63.2%. The overall exergy efficiency value for the system on a product/fuel basis is found to be 60.7%. (author)

  6. Study of Air Ingress Across the Duct During the Accident Conditions

    International Nuclear Information System (INIS)

    Hassan, Yassin

    2013-10-01

    The goal of this project is to study the fundamental physical phenomena associated with air ingress in very high temperature reactors (VHTRs). Air ingress may occur due to a rupture of primary piping and a subsequent breach in the primary pressure boundary in helium-cooled and graphite-moderated VHTRs. Significant air ingress is a concern because it introduces potential to expose the fuel, graphite support rods, and core to a risk of severe graphite oxidation. Two of the most probable air ingress scenarios involve rupture of a control rod or fuel access standpipe, and rupture in the main coolant pipe on the lower part of the reactor pressure vessel. Therefore, establishing a fundamental understanding of air ingress phenomena is critical in order to rationally evaluate safety of existing VHTRs and develop new designs that minimize these risks. But despite this importance, progress toward development these predictive capabilities has been slowed by the complex nature of the underlying phenomena. The combination of inter-diffusion among multiple species, molecular diffusion, natural convection, and complex geometries, as well as the multiple chemical reactions involved, impose significant roadblocks to both modeling and experiment design. The project team will employ a coordinated experimental and computational effort that will help gain a deeper understanding of multiphased air ingress phenomena. This project will enhance advanced modeling and simulation methods, enabling calculation of nuclear power plant transients and accident scenarios with a high degree of confidence. The following are the project tasks: Perform particle image velocimetry measurement of multiphase air ingresses; and, Perform computational fluid dynamics analysis of air ingress phenomena.

  7. Pathologic analysis of control plans for air pollution management in tehran metropolis: A qualitative study

    Directory of Open Access Journals (Sweden)

    Narges Salehi Shahrabi

    2013-01-01

    Full Text Available Background: Regarding the importance of air pollution issue for large cities, as Tehran metropolis, many plans, programs, projects and regulations have been developed to manage urban air pollution. However, most of them failed to decline the pollution. The purpose of this study is to pathologically analyze air-pollution control plans in order to offer effective solutions for Tehran metropolis. Methods: A qualitative content analysis and a semi-structured interview with 14 practicing professionals were used to identify key causes and sources of Tehran′s air pollution, to recognize challenges and obstacles towards effective performance of air-pollution control plans in this metropolitan area, and to suggest the most effective controlling solutions. Results: Challenges related to air-pollution control plans can be divided into two major categories: Firstly lack of integrated and organized stewardship and secondly those related to political, economical, social and technical environmental abbreviated as PEST, challenges. For effective control of the Tehran air pollution, the following eight controlling alternatives were identified: Systematization of plan preparation process, organizing the stewardship, standardization and utilization of new technologies and professional experts, cultural and infrastructural development, realization of social justice, developing coordination and controlling mechanisms, improving citizen′s participatory capacity, and focusing on effective management of fuel and energy. Conclusions: Controlling air pollution in Tehran should be considered as a priority for policymakers to make enforcements through applying a systemic cycle of preparation effective and comprehensive plans. Further, implement the enforcements and evaluate the environmental impact of the plans through involving all stakeholders.

  8. Study of Air Ingress Across the Duct During the Accident Conditions

    Energy Technology Data Exchange (ETDEWEB)

    Hassan, Yassin [Texas A & M Univ., College Station, TX (United States)

    2013-05-06

    The goal of this project is to study the fundamental physical phenomena associated with air ingress in very high temperature reactors (VHTRs). Air ingress may occur due to a rupture of primary piping and a subsequent breach in the primary pressure boundary in helium-cooled and graphite-moderated VHTRs. Significant air ingress is a concern because it introduces potential to expose the fuel, graphite support rods, and core to a risk of severe graphite oxidation. Two of the most probable air ingress scenarios involve rupture of a control rod or fuel access standpipe, and rupture in the main coolant pipe on the lower part of the reactor pressure vessel. Therefore, establishing a fundamental understanding of air ingress phenomena is critical in order to rationally evaluate safety of existing VHTRs and develop new designs that minimize these risks. But despite this importance, progress toward development these predictive capabilities has been slowed by the complex nature of the underlying phenomena. The combination of inter-diffusion among multiple species, molecular diffusion, natural convection, and complex geometries, as well as the multiple chemical reactions involved, impose significant roadblocks to both modeling and experiment design. The project team will employ a coordinated experimental and computational effort that will help gain a deeper understanding of multiphased air ingress phenomena. This project will enhance advanced modeling and simulation methods, enabling calculation of nuclear power plant transients and accident scenarios with a high degree of confidence. The following are the project tasks: Perform particle image velocimetry measurement of multiphase air ingresses; and, Perform computational fluid dynamics analysis of air ingress phenomena.

  9. Investigation of air pollutants in rural nursery school - a case study

    Science.gov (United States)

    Mainka, Anna; Zajusz-Zubek, Elwira; Kozielska, Barbara; Brągoszewska, Ewa

    2018-01-01

    Children's exposure to air pollutants is an important public health challenge. Indoor air quality (IAQ) in nursery school is believed to be different from elementary school. Moreover, younger children are more vulnerable to air pollution than higher grade children because they spend more time indoors, and their immune systems and bodies are less mature. The purpose of this study was to evaluate the indoor air quality (IAQ) at naturally ventilated rural nursery schools located in Upper Silesia, Poland. We investigated the concentrations of volatile organic compounds (VOCs), particulate matter (PM), bacterial and fungal bioaerosols, as well as carbon dioxide (CO2) concentrations in younger and older children's classrooms during the winter and spring seasons. The concentration of the investigated pollutants in indoor environments was higher than those in outdoor air. The results indicate the problem of elevated concentrations of PM2.5 and PM10 inside the examined classrooms, as well as that of high levels of CO2 exceeding 1,000 ppm in relation to outdoor air. The characteristics of PM and CO2 levels were significantly different, both in terms of classroom occupation (younger or older children) and of season (winter or spring).

  10. Comparative Study of Convective Heat Transfer Performance of Steam and Air Flow in Rib Roughened Channels

    Science.gov (United States)

    Ma, Chao; Ji, Yongbin; Ge, Bing; Zang, Shusheng; Chen, Hua

    2018-04-01

    A comparative experimental study of heat transfer characteristics of steam and air flow in rectangular channels roughened with parallel ribs was conducted by using an infrared camera. Effects of Reynolds numbers and rib angles on the steam and air convective heat transfer have been obtained and compared with each other for the Reynolds number from about 4,000 to 15,000. For all the ribbed channels the rib pitch to height ratio (p/e) is 10, and the rib height to the channel hydraulic diameter ratio is 0.078, while the rib angles are varied from 90° to 45°. Based on experimental results, it can be found that, even though the heat transfer distributions of steam and air flow in the ribbed channels are similar to each other, the steam flow can obtain higher convective heat transfer enhancement capability, and the heat transfer enhancement of both the steam and air becomes greater with the rib angle deceasing from 90° to 45°. At Reynolds number of about 12,000, the area-averaged Nusselt numbers of the steam flow is about 13.9%, 14.2%, 19.9% and 23.9% higher than those of the air flow for the rib angles of 90°, 75°, 60° and 45° respectively. With the experimental results the correlations for Nusselt number in terms of Reynolds number and rib angle for the steam and air flow in the ribbed channels were developed respectively.

  11. Research on Value Assessment and Compensation for Health Hazards of Urban Air Pollution-A Case Study of Urumqi

    OpenAIRE

    Yu, Chen; Hui, Sun

    2016-01-01

    ABSTRACT With the acceleration of urbanization and industrialization, urban air pollution has become a serious threat to the health of urban residents. In this study, to investigate health hazards caused by air pollution for urban residents, concentrations of main air pollutants and annual coal consumption amounts during the period from 2000 to 2013 were analyzed. Our results showed that economic losses of Urumqi caused by air pollution amounted to 63.155 million yuan in 2013, accounting for ...

  12. Anaerobic culture by Total Air Barrier: A preliminary study

    Directory of Open Access Journals (Sweden)

    Soma Sarkar

    2010-03-01

    Full Text Available BackgroundFor study with obligate anaerobes, inoculated platescontaining suitable reduced media need handling andincubation under strict anaerobic condition. Instead ofensuring a confined oxygen free chamber for placing seededplates, same purpose may be achieved by creating total airbarrier to the surface.MethodUpper moist surface of freshly prepared anaerobic media inPetri plates were intimately covered with very thintransparent bacteriological inert sterile polyester sheets.Stock culture of Bacteroides fragilis, ATCC 23745 andClostridium sporogenes, ATCC 11437 were grown in cookedmeat broth and then sub-cultured on respective plates, afterlifting the cover sheets. Sheets were again covered andincubated at 37oC ordinary incubator. To performantimicrobial susceptibility test, similarly covered seededplates with well inoculums were inverted en-block afterstripping sides with the help of a spatula. Now antibiotic diskswere placed on upper bare surfaces. After short pre-diffusion,plates were incubated keeping inoculated surface below.Same study was performed by conventional method usingGaspak.ResultsGood growths were noted in both sets of the study;however discrete colonies appeared more flat in nature intest set. Almost identical zones of inhibition were noted inboth sets of sensitivity study. Seven days old growths incovered blood agar plates were found viable when subculturedin cooked meat broths.ConclusionIsolation, identification and susceptibility study for mostclinically important obligate anaerobes may be performedby simple barrier method after appropriatestandardization.

  13. Public Health and Air Pollution in Asia (PAPA): a multicity study of short-term effects of air pollution on mortality.

    Science.gov (United States)

    Wong, Chit-Ming; Vichit-Vadakan, Nuntavarn; Kan, Haidong; Qian, Zhengmin

    2008-09-01

    Although the deleterious effects of air pollution from fossil fuel combustion have been demonstrated in many Western nations, fewer studies have been conducted in Asia. The Public Health and Air Pollution in Asia (PAPA) project assessed the effects of short-term exposure to air pollution on daily mortality in Bangkok, Thailand, and in three cities in China: Hong Kong, Shanghai, and Wuhan. Poisson regression models incorporating natural spline smoothing functions were used to adjust for seasonality and other time-varying covariates that might confound the association between air pollution and mortality. Effect estimates were determined for each city and then for the cities combined using a random effects method. In individual cities, associations were detected between most of the pollutants [nitrogen dioxide, sulfur dioxide, particulate matter air pollution than those in Western industrial nations because they spend more time outdoors and less time in air conditioning. Although the social and environmental conditions may be quite different, it is reasonable to apply estimates derived from previous health effect of air pollution studies in the West to Asia.

  14. Multicity study of air pollution and mortality in Latin America (the ESCALA study).

    Science.gov (United States)

    Romieu, Isabelle; Gouveia, Nelson; Cifuentes, Luis A; de Leon, Antonio Ponce; Junger, Washington; Vera, Jeanette; Strappa, Valentina; Hurtado-Díaz, Magali; Miranda-Soberanis, Victor; Rojas-Bracho, Leonora; Carbajal-Arroyo, Luz; Tzintzun-Cervantes, Guadalupe

    2012-10-01

    The ESCALA* project (Estudio de Salud y Contaminación del Aire en Latinoamérica) is an HEI-funded study that aims to examine the association between exposure to outdoor air pollution and mortality in nine Latin American cities, using a common analytic framework to obtain comparable and updated information on the effects of air pollution on several causes of death in different age groups. This report summarizes the work conducted between 2006 and 2009, describes the methodologic issues addressed during project development, and presents city-specific results of meta-analyses and meta-regression analyses. The ESCALA project involved three teams of investigators responsible for collection and analysis of city-specific air pollution and mortality data from three different countries. The teams designed five different protocols to standardize the methods of data collection and analysis that would be used to evaluate the effects of air pollution on mortality (see Appendices B-F). By following the same protocols, the investigators could directly compare the results among cities. The analysis was conducted in two stages. The first stage included analyses of all-natural-cause and cause-specific mortality related to particulate matter Chile, and México. Analyses for PM10 and O3 were also stratified by age group and O3 analyses were stratified by season. Generalized linear models (GLM) in Poisson regression were used to fit the time-series data. Time trends and seasonality were modeled using natural splines with 3, 6, 9, or 12 degrees of freedom (df) per year. Temperature and humidity were also modeled using natural splines, initially with 3 or 6 df, and then with degrees of freedom chosen on the basis of residual diagnostics (i.e., partial autocorrelation function [PACF], periodograms, and a Q-Q plot) (Appendix H, available on the HEI Web site). Indicator variables for day-of-week and holidays were used to account for short-term cyclic fluctuations. To assess the

  15. A Visualization Approach to Air Pollution Data Exploration—A Case Study of Air Quality Index (PM2.5 in Beijing, China

    Directory of Open Access Journals (Sweden)

    Huan Li

    2016-02-01

    Full Text Available In recent years, frequent occurrences of significant air pollution events in China have routinely caused panic and are a major topic of discussion by the public and air pollution experts in government and academia. Therefore, this study proposed an efficient visualization method to represent directly, quickly, and clearly the spatio-temporal information contained in air pollution data. Data quality check and cleansing during a preliminary visual analysis is presented in tabular form, heat matrix, or line chart, upon which hypotheses can be deduced. Further visualizations were designed to verify the hypotheses and obtain useful findings. This method was tested and validated in a year-long case study of the air quality index (AQI of PM2.5 in Beijing, China. We found that PM2.5, PM10, and NO2 may be emitted by the same sources, and strong winds may accelerate the spread of pollutants. The average concentration of PM2.5 in Beijing was greater than the AQI value of 50 over the six-year study period. Furthermore, arable lands exhibited considerably higher concentrations of air pollutants than vegetation-covered areas. The findings of this study showed that our visualization method is intuitive and reliable through data quality checking and information sharing with multi-perspective air pollution graphs. This method allows the data to be easily understood by the public and inspire or aid further studies in other fields.

  16. Relationship of Indoor, Outdoor and Personal Air (RIOPA) study: study design, methods and quality assurance/control results.

    Science.gov (United States)

    Weisel, Clifford P; Zhang, Junfeng; Turpin, Barbara J; Morandi, Maria T; Colome, Steven; Stock, Thomas H; Spektor, Dalia M; Korn, Leo; Winer, Arthur; Alimokhtari, Shahnaz; Kwon, Jaymin; Mohan, Krishnan; Harrington, Robert; Giovanetti, Robert; Cui, William; Afshar, Masoud; Maberti, Silvia; Shendell, Derek

    2005-03-01

    The Relationship of Indoor, Outdoor and Personal Air (RIOPA) Study was undertaken to evaluate the contribution of outdoor sources of air toxics, as defined in the 1990 Clean Air Act Amendments, to indoor concentrations and personal exposures. The concentrations of 18 volatile organic compounds (VOCs), 17 carbonyl compounds, and fine particulate matter mass (PM(2.5)) were measured using 48-h outdoor, indoor and personal air samples collected simultaneously. PM2.5 mass, as well as several component species (elemental carbon, organic carbon, polyaromatic hydrocarbons and elemental analysis) were also measured; only PM(2.5) mass is reported here. Questionnaires were administered to characterize homes, neighborhoods and personal activities that might affect exposures. The air exchange rate was also measured in each home. Homes in close proximity (<0.5 km) to sources of air toxics were preferentially (2:1) selected for sampling. Approximately 100 non-smoking households in each of Elizabeth, NJ, Houston, TX, and Los Angeles, CA were sampled (100, 105, and 105 respectively) with second visits performed at 84, 93, and 81 homes in each city, respectively. VOC samples were collected at all homes, carbonyls at 90% and PM(2.5) at 60% of the homes. Personal samples were collected from nonsmoking adults and a portion of children living in the target homes. This manuscript provides the RIOPA study design and quality control and assurance data. The results from the RIOPA study can potentially provide information on the influence of ambient sources on indoor air concentrations and exposure for many air toxics and will furnish an opportunity to evaluate exposure models for these compounds.

  17. Preliminary study on aluminum-air battery applying disposable soft drink cans and Arabic gum polymer

    Science.gov (United States)

    Alva, S.; Sundari, R.; Wijaya, H. F.; Majlan, E. H.; Sudaryanto; Arwati, I. G. A.; Sebayang, D.

    2017-09-01

    This study is in relation to preliminary investigation of aluminium-air battery using disposable soft drink cans as aluminium source for anode. The cathode uses commercial porous carbon sheet to trap oxygen from air. This work applies a commercial cashing to place carbon cathode, electrolyte, Arabic gum polymer, and aluminium anode in a sandwich-like arrangement to form the aluminium-air battery. The Arabic gum as electrolyte polymer membrane protects anode surface from corrosion due to aluminium oxide formation. The study result shows that the battery discharge test using constant current loading of 0.25 mA yields battery capacity of 0.437 mAh with over 100 minute battery life times at 4M NaOH electrolyte and 20 % Arabic gum polymer as the best performance in this investigation. This study gives significant advantage in association with beneficiation of disposable soft drink cans from municipal solid waste as aluminium source for battery anode.

  18. Performance study of solar air heater duct having absorber plate with V down perforated baffles

    Directory of Open Access Journals (Sweden)

    Sunil Chamoli

    2014-04-01

    Full Text Available This paper presents results of a study of the performance of solar air heaters with V down perforated baffles as roughness on the air flow side of the absorber plate. Investigations have been carried out using a mathematical model to study the effects of ambient conditions, operating and design parameters on effective efficiency of such air heaters. The thermal and effective efficiencies differ only marginally at lower flow rates. With an increase in the flow rate, the difference between the thermal and effective efficiencies increases because of the increase in the pumping power. The results of the study are presented in the form of plots to show the effect of ambient, design and operating conditions on thermal and effective efficiency.

  19. Air Force Leadership Study: The Need for Deliberate Development

    Science.gov (United States)

    2012-02-01

    Abraham Maslow , once the basic needs of survival and security are met, people concern themselves with higher needs like affection, be- longing, the...maintaining the data needed , and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of...Study: The Need for Deliberate Development 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER 5e

  20. Technician Hiring in the Air National Guard: A Timeline Study

    Science.gov (United States)

    2017-06-01

    probability, convenience type. SECTION 2: CASE STUDY RESULTS AND DISCUSSION The research conducted for this paper identifies several major themes...hiring timelines. As with the Wings’ responses, some of the HQs indicated they do not track the re- quested data or provided qualitative data not...Wing and state leadership. The A1 sub-council of the MSG/CCs’ Council must form a group of subject matter experts in ANG hiring (with re- gional

  1. Building America Case Study: Air Leakage and Air Transfer Between Garage and Living Space, Waldorf, Maryland (Fact Sheet)

    Energy Technology Data Exchange (ETDEWEB)

    2014-11-01

    This research project focused on evaluation of air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multi-point fan pressurization tests and additional zone pressure diagnostic testing characterized the garage and house air leakage, the garage-to-house air leakage, and garage and house pressure relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed. For houses employing whole-house supply ventilation (positive pressure) or balanced ventilation (same pressure effect as the Baseline condition), adherence to the EPA Indoor airPLUS house-to-garage air sealing requirements should be sufficient to expect little to no garage-to-house air transfer.

  2. Use of a sealant to prevent prolonged air leaks after lung resection: a prospective randomized study

    Directory of Open Access Journals (Sweden)

    Lequaglie Cosimo

    2012-10-01

    Full Text Available Abstract Background Pulmonary air leaks are common complications of lung resection and result in prolonged hospital stays and increased costs. The purpose of this study was to investigate whether, compared with standard care, the use of a synthetic polyethylene glycol matrix (CoSeal® could reduce air leaks detected by means of a digital chest drain system (DigiVent™, in patients undergoing lung resection (sutures and/or staples alone. Methods Patients who intraoperatively showed moderate or severe air leaks (evaluated by water submersion tests were intraoperatively randomized to receive just sutures/staples (control group or sutures/staples plus CoSeal® (sealant group. Differences among the groups in terms of air leaks, prolonged air leaks, time to chest tube removal, length of hospital stay and related costs were assessed. Results In total, 216 lung resection patients completed the study. Nineteen patients (18.1% in the control group and 12 (10.8% patients in the sealant group experienced postoperative air leaks, while a prolonged air leak was recorded in 11.4% (n = 12 of patients in the control group and 2.7% (n = 3 of patients in the sealant group. The difference in the incidence of air leaks and prolonged air leaks between the two groups was statistically significant (p = 0.0002 and p = 0.0013. The mean length of hospital stay was significantly shorter in the sealant group (4 days than the control group (8 days (p = 0.0001. We also observed lower costs in the sealant group than the control group. Conclusion The use of CoSeal® may decrease the occurrence and severity of postoperative air leaks after lung resection and is associated with shorter hospital stay. Trial registration Not registered. The trial was approved by the Institutional Review Board of the IRCCS-CROB Basilicata Regional Cancer Institute, Rionero in Vulture, Italy.

  3. Comparitive study of ambient air quality status for big cities of Punjab (Pakistan)

    International Nuclear Information System (INIS)

    Shahid, M.A.K.; Mahmood, A.

    2010-01-01

    This study was undertaken to investigate the quality of air in Lahore and Faisalabad at selected sites. Total eight sampling stations were selected and all the sampling locations fall in different environmental backdrops such as residential, commercial, industrial and rural (control) areas. To study the quality of air, Suspended Particulate Matter (SPM), Nitrogen dioxide (NO/sub 2/) and Sulphur dioxide (SO/sub 2/) were selected In the present study, it was found that the SPM NO/sub 2/ and SO/sub 2/ levels in all the sampling locations are within the permissible limits. However, the raising levels indicated at Residential cum Industrial area (shopping complex along with banks) followed by pure industrial area. The source of these pollutants is primarily transport sector and secondly industries. The ambient air quality reported to be low except 2Kl reported as medium. Sociological survey was conducted to determine the health hazards and the diseases related to air pollution. The results were alarming and found to be compatible with Punjab Public Health and Engineering Department (PPHE). There fore it is suggested that air quality management demands. (author)

  4. Public engagement on urban air pollution: an exploratory study of two interventions.

    Science.gov (United States)

    Oltra, Christian; Sala, Roser; Boso, Àlex; Asensio, Sergi López

    2017-06-01

    The use of portable sensors to measure air quality is a promising approach for the management of urban air quality given its potential to improve public participation in environmental issues and to promote healthy behaviors. However, not all the projects that use air quality mobile sensors consider the potential effects of their use on the attitudes and behaviors of non-expert individuals. This study explores the experiences, perceptions, attitudes, and behavioral intentions of 12 participants who used a real-time NO 2 sensor over a period of 7 days in the metropolitan area of Barcelona and compares them with 16 participants who did not have access to the device but rather to documentary information. The study design is based on recombined focus groups who met at the beginning and end of a 7-day activity. The results suggest that the experience with the sensors, in comparison with the traditional information, generates greater motivation among participants. Also, that the use of the sensor seems to support a more specific awareness of the problem of air pollution. In relation to risk perception, the textual and visual information seems to generate stronger beliefs of severity among participants. In both groups, beliefs of low controllability and self-efficacy are observed. Neither using the sensor nor reading the documentary information seems to contribute positively in this sense. The results of the study aim to contribute to the design of public involvement strategies in urban air pollution.

  5. Experimental study of an air conditioning system to control a greenhouse microclimate

    International Nuclear Information System (INIS)

    Attar, I.; Naili, N.; Khalifa, N.; Hazami, M.; Lazaar, M.; Farhat, A.

    2014-01-01

    Highlights: • Contribution in the control of the greenhouse microclimate for pepper cultivation. • The energy storing in the ground and in the water ensure the greenhouse heating. • The circulation of the cold water in the exchangers ensures the greenhouse cooling. • The system makes the greenhouse appropriate for the pepper cultivation whole year. - Abstract: In this papper, a thermal model is developed to investigate the possibility to use the ground thermal energy for the greenhouse heating or cooling. A control system of the ground heat storing is integrated in a chapel greenhouse located in the premises of the Technology and Research Energy Center, Tunis, Tunisia. Polypropylene capillary heat exchangers, suspended in the air and buried into the ground of the greenhouse, are used to store or destore solar energy excess. During the day, the air-suspended exchangers recuperate the solar energy in excess. This recuperated energy is then stored into the ground through the buried exchangers. At night the stored thermal energy is brought back by the suspended exchangers to heat the greenhouse air. The purpose of this study is to contribute in the greenhouse microclimate control. In order to maintain the greenhouse air temperature at 20 °C, suitable for a defined agriculture, the solar energy and the cold water are respectively used for heating and cooling the greenhouse inside air. The design and construction of a chapel greenhouse equipped with the control system is carried out. The studied system is used, at the same time for; heating, cooling the greenhouse air and storing the solar energy in excess. Experiments were conducted during the years 2012–2013, to evaluate the effectiveness of the control system achieved. The measured values of the greenhouse air temperatures with and without the control system are discussed

  6. Air pollution and respiratory health of children: the PEACE panel study in Umea., Sweden.

    NARCIS (Netherlands)

    Forsberg, B.; Segerstedt, B.; Stjernberg, N.; Roemer, W.

    1998-01-01

    The Pollution Effects on Asthmatic Children in Europe (PEACE) study examined the acute effects of short-term changes in air pollution on symptomatic children. We were one of 14 research centres in Europe that used a common study protocol. Seventy five children in an urban panel and 72 children in a

  7. Air pollution and respiratory health of children: the PEACE panel study in Teplice, Czech Republic.

    NARCIS (Netherlands)

    Kotesovec, F.; Vitnerova, N.; Leixner, M.; Benes, I.; Skoorkovsky, J.; Roemer, W.

    1998-01-01

    As part of a multicentre study (the Pollution Effects on Asthmatic Children in Europe (PEACE) project) the acute effects of air pollution on the health of susceptible children was investigated. Eighty nine children in the urban and 77 children in the rural area were followed during the study period

  8. Air pollution and respiratory health of children: the PEACE panel study in Krakow., Poland.

    NARCIS (Netherlands)

    Haluszka, J.; Pisiewics, K.; Miczynski, J.; Roemer, W.; Tomalak, W.

    1998-01-01

    The Krakow panel study was performed as part of the Pollution Effects on Asthmatic Children in Europe (PEACE) project. The aim of the study was to examine the acute effects of short-term changes in air pollution on symptomatic children. Krakow served as the urban area and Rabka, a small health

  9. STUDY ON POLLEN VIABILITY AS BIOINDICATOR OF AIR QUALITY

    Directory of Open Access Journals (Sweden)

    Florentina ŞTEFLEA

    2012-01-01

    Full Text Available The aim of this research is to estimate the relationship between pollen viability and atmospheric pollution (in polluted and non-polluted conditions. The study was carried out in the city of Timisoara. Two areas, with different intensity of road traffic (very high and absent but all characterized by the presence of the same plant species, were selected. The pollen of herbaceous spontaneous species, arboreal species and a shrub species was used (Robinia pseudacacia, Aesculus x carnea, Catalpa bignonioides, Albizzia julibrissin, Rosa canina, Sambucus nigra, Malva neglecta, Ranunculus acer, Trifolium repens, Cichorium intybus. The pollen of these species was treated with TTC (2, 3, 5 Tryphenil-Tetrazolium-Chloride staining solution and viability was then estimated by light microscopy. The results of the mean pollen viability percentage of the examined species are reported. Pollen viability of herbaceous plants is significantly different between the two environments.

  10. Experimental study of perforated suspended ceilings as diffuse ventilation air inlets

    DEFF Research Database (Denmark)

    Hviid, Christian Anker; Svendsen, Svend

    2013-01-01

    An experimental study is reported in this paper for a diffuse ceiling ventilation concept. The analyses were carried out with two different porous surfaces mounted in a suspended ceiling: perforated tiles of aluminium and of gypsum. Ventilation air was supplied above the suspended ceiling effecti...... surface which increases the potential and applicability of the concept. Risk of thermal discomfort was not disclosed but the study did show evidence of large fluctuating air movements which could stem from transient behaviour creating sensations of draught to the occupants....

  11. Air pollution and cardiovascular and respiratory disease: Rationale and methodology of CAPACITY study

    Science.gov (United States)

    Rabiei, Katayoun; Hosseini, Sayed Mohsen; Sadeghi, Erfan; Jafari-Koshki, Tohid; Rahimi, Mojtaba; Shishehforoush, Mansour; Lahijanzadeh, Ahmadreza; Sadeghian, Babak; Moazam, Elham; Mohebi, Mohammad Bagher; Ezatian, Victoria; Sarrafzadegan, Nizal

    2017-01-01

    BACKGROUND Considering the high level of air pollution and its impact on health, we aimed to study the correlation of air pollution with hospitalization and mortality of cardiovascular (CVD) and respiratory diseases (ResD) (CAPACITY) to determine the effects of air pollutants on CVD and ResD hospitalizations and deaths in Isfahan, Iran. METHODS Hourly levels of air pollutants including particulate matter (PM), carbon monoxide (CO), nitrogen dioxide (NO2), sulfur dioxide (SO2), and ozone (O3), information of CVD and ResD admissions and death certificate were obtained respectively from Department of Environment (DOE), Iran, hospitals and cemetery. Time series and case-crossover model were used to find the impact of air pollutants. This paper only summarizes the descriptive findings of the CAPACITY study. RESULTS The total number of hospitalized patients were 23781 in 2010 and 22485 in 2011. The most frequent cause of hospitalization and death was ischemic heart diseases in both years. While the mean annual levels of O3, CO, and PM10 were lower in 2011 than in 2010, NO2 and SO2 levels higher in 2011. In both years, PM10 was similarly increased during last month of fall, late spring and early summer. In 2011, the PM2.5 and PM10 monthly trend of change were similar. CONCLUSION The CAPACITY study is one of the few large-scale studies that evaluated the effects of air pollutants on a variety of CVD and ResD in a large city of Iran. This study can provide many findings that could clarify the effects of these pollutants on the incidence and burden of both disease groups. PMID:29643921

  12. Air pollution and cardiovascular and respiratory disease: Rationale and methodology of CAPACITY study.

    Science.gov (United States)

    Rabiei, Katayoun; Hosseini, Sayed Mohsen; Sadeghi, Erfan; Jafari-Koshki, Tohid; Rahimi, Mojtaba; Shishehforoush, Mansour; Lahijanzadeh, Ahmadreza; Sadeghian, Babak; Moazam, Elham; Mohebi, Mohammad Bagher; Ezatian, Victoria; Sarrafzadegan, Nizal

    2017-11-01

    Considering the high level of air pollution and its impact on health, we aimed to study the correlation of air pollution with hospitalization and mortality of cardiovascular (CVD) and respiratory diseases (ResD) (CAPACITY) to determine the effects of air pollutants on CVD and ResD hospitalizations and deaths in Isfahan, Iran. Hourly levels of air pollutants including particulate matter (PM), carbon monoxide (CO), nitrogen dioxide (NO2), sulfur dioxide (SO2), and ozone (O3), information of CVD and ResD admissions and death certificate were obtained respectively from Department of Environment (DOE), Iran, hospitals and cemetery. Time series and case-crossover model were used to find the impact of air pollutants. This paper only summarizes the descriptive findings of the CAPACITY study. The total number of hospitalized patients were 23781 in 2010 and 22485 in 2011. The most frequent cause of hospitalization and death was ischemic heart diseases in both years. While the mean annual levels of O3, CO, and PM10 were lower in 2011 than in 2010, NO2 and SO2 levels higher in 2011. In both years, PM10 was similarly increased during last month of fall, late spring and early summer. In 2011, the PM2.5 and PM10 monthly trend of change were similar. The CAPACITY study is one of the few large-scale studies that evaluated the effects of air pollutants on a variety of CVD and ResD in a large city of Iran. This study can provide many findings that could clarify the effects of these pollutants on the incidence and burden of both disease groups.

  13. Air pollution and cardiovascular and respiratory disease: Rationale and methodology of CAPACITY study

    Directory of Open Access Journals (Sweden)

    Katayoun Rabiei

    2017-11-01

    Full Text Available BACKGROUND: Considering the high level of air pollution and its impact on health, we aimed to study the correlation of air pollution with hospitalization and mortality of cardiovascular (CVD and respiratory diseases (ResD (CAPACITY to determine the effects of air pollutants on CVD and ResD hospitalizations and deaths in Isfahan, Iran.METHODS: Hourly levels of air pollutants including particulate matter (PM, carbon monoxide (CO, nitrogen dioxide (NO2, sulfur dioxide (SO2, and ozone (O3, information of CVD and ResD admissions and death certificate were obtained respectively from Department of Environment (DOE, Iran, hospitals and cemetery. Time series and case-crossover model were used to find the impact of air pollutants. This paper only summarizes the descriptive findings of the CAPACITY study.RESULTS: The total number of hospitalized patients were 23781 in 2010 and 22485 in 2011. The most frequent cause of hospitalization and death was ischemic heart diseases in both years. While the mean annual levels of O3, CO, and PM10 were lower in 2011 than in 2010, NO2 and SO2 levels higher in 2011. In both years, PM10 was similarly increased during last month of fall, late spring and early summer. In 2011, the PM2.5 and PM10 monthly trend of change were similar.CONCLUSION: The CAPACITY study is one of the few large-scale studies that evaluated the effects of air pollutants on a variety of CVD and ResD in a large city of Iran. This study can provide many findings that could clarify the effects of these pollutants on the incidence and burden of both disease groups. 

  14. [Prevention and control of air pollution needs to strengthen further study on health damage caused by air pollution].

    Science.gov (United States)

    Wu, T C

    2016-08-06

    Heath issues caused by air pollution such as particulate matter (PM) are much concerned and focused among air, water and soil pollutions because human breathe air for whole life span. Present comments will review physical and chemical characteristics of PM2.5 and PM10; Dose-response associations of PM10, PM2.5 and their components with mortality and risk of cardiopulmonary diseases, early health damages such as the decrease of lung functions and heart rate variability, DNA damage; And the roles of genetic variations and epigenetic changes in lung functions and heart rate variability, DNA damage related to PMs and their components. This comments list some limitations and perspectives about the associations of air pollution with health.

  15. New Results from Air Pollution Studies in Romania

    CERN Document Server

    Stan, O A; Frontasyeva, M V; Steinnes, E

    2000-01-01

    Results from the next stage of the project "Atmospheric Deposition of Heavy Metals in Rural and Urban Areas of Romania Studied by the Moss Biomonitoring Technique Employing Nuclear and Related Analytical Techniques", carried out under the auspieces of the International Atomic Energy Agency, Vienna, are reported. A total of 70 moss samples (Hypnum Cupressiforme) were collected from highly polluted areas in the north-eastern part of Transylvania during the summer of 1999. The samples were analyzed by epithermal neutron activation analysis at the pulsed fast reactor IBR-2 at JINR, Dubna, for a wide range of elements including heavy metals and rare earths (Na, Mg, Al, Cl, K, Ca, Sc, V, Cr, Mn, Fe, Co, Ni ((n,p) reaction), Cu, Zn, As, Se, Br, Rb, Sr, Zr, Mo, Ag, Sn, Sb, I, Cs, Ba, La, Ce, Nb, Sm, Eu, Gd, Tb, Hf, Ta, W, Au, Th, and U). IAEA certified reference materials were used to ensure the quality of the measurements. The regional extent of pollution patterns of specific metals was determined. Like another stro...

  16. Numerical study on the characteristics of air bubble oscillation in water

    International Nuclear Information System (INIS)

    Kim, Hwan Yeol; Bae, Yoon Yeong

    2003-01-01

    In both a boiling water reactor and an advanced type of pressurized water reactor under construction in Korea named APR1400, when a pressure relieving system is in operation, water, air and steam discharge successively into a sub-cooled water pool through spargers. Among the phenomena occurring during the discharging processes, the air bubble clouds with a low-frequency and high-amplitude oscillation may result in significant damage to the submerged structures if the resonance between the bubble clouds and structures occur. The phenomena involved are so complicated that most predictions of frequency and pressure loads have resorted to experimental work and computational approach has been precluded. This study deals with a numerical prediction of the pressure field generated by the oscillation of air bubble. The analysis was performed by using a commercial thermal hydraulic analysis code, FLUENT, version 4.5. The multiphase flows of water, air and steam were simulated by the VOF (Volume Of Fluid) model contained in the code. Unlike the author's previous study, the LRR (Load Reduction Ring) of the sparger is artificially blocked for the investigation of LRR effects on the pressure field. It also includes the effect of air mass and inlet pressure in the piping on the pressure field. (author)

  17. Roadside air quality and implications for control measures: A case study of Hong Kong

    Science.gov (United States)

    Ai, Z. T.; Mak, C. M.; Lee, H. C.

    2016-07-01

    Traffic related air pollution is one of major environmental issues in densely populated urban areas including Hong Kong. A series of control measures has been implemented by Hong Kong government to cut traffic related air pollutants, including retrofitting the Euro II and Euro III buses with selective catalytic reduction (SCR) devices to lower nitrogen dioxide (NO2) emissions. In order to reveal the real-life roadside air quality and evaluate the effectiveness of the control measures, this study first analyzed the recent six-year data regarding concentrations of pollutants typically associated with traffic recorded in two governmental roadside monitoring stations and second conducted on-site measurements of concentration of pollutants at pedestrian level near five selected roads. Given that there is a possibility of ammonia leakage as a secondary pollutant from SCR devices, a special attention was paid to the measurements of ammonia level in bus stations and along roadsides. Important influencing factors, such as traffic intensity, street configuration and season, were analyzed. Control measures implemented by the government are effective to decrease the traffic emissions. In 2014, only NO2 cannot achieve the annual air quality objective of Hong Kong. However, it is important to find that particulate matters, rather than NO2, post potentially a short-term exposure risk to passengers and pedestrians. Based on the findings of this study, specific control measures are suggested, which are intended to further improve the roadside air quality.

  18. Respiratory alterations due to urban air pollution: An experimental study in rats

    International Nuclear Information System (INIS)

    Saldiva, P.H.N.; King, M.; Delmonte, V.L.C.; Macchione, M.; Parada, M.A.C.; Daliberto, M.L.; Sakae, R.S.; Criado, P.M.P.; Silveira, P.L.P.; Zin, W.A.; Boehm, G.M.

    1992-01-01

    In order to assess the adverse effects of urban levels of air pollution, rats were used as biological indicators in a chronic exposure experiment. Animals were housed for 6 months in the center of Sao Paulo and were compared to controls kept for the same period in a clean area. Pollution levels were obtained from a State air pollution monitoring station, 200 m distant from the exposure place, which provided the levels of CO, SO 2 , particulates, and ozone. The animals were submitted to several tests focusing on the respiratory system, comprising pulmonary function tests, studies on mucociliary clearance and mucus rheology, histochemical evaluation of airways, bronchoalveolar lavage, and ultrastructural studies of the epithelium of the airways. Rats exposed to air pollution developed secretory cell hyperplasia in the airways, ultrastructural ciliary alterations, and a more rigid mucus, changes that caused mucociliary clearance impairment. In addition, nasal resistance and the number of inflammatory cells recovered by bronchoalveolar lavage were increased in air pollution exposed animals. The results obtained in the present investigation suggest that chronic exposure to urban levels of air pollution may cause respiratory lesions in rats

  19. Two studies on the effects of small exhaust fans on indoor air quality: Field study of exhaust fans for mitigating indoor air quality problems; Indoor air quality, exhaust fan mitigation

    International Nuclear Information System (INIS)

    1987-07-01

    Overall, the findings show that exhaust fans basically provide small amounts of ventilation compensation. By monitoring the common indoor air pollutants (radon, formaldehyde, carbon monoxide, nitrogen dioxide, and water vapor), it was found that the quality of the indoor air was not adversely affected by the use of exhaust fans. Nor did their use provide any measurable or significant benefits since no improvement in air quality was ascertained. While exhaust fans of this small size did not increase radon, which is the contaminant of most concern, the researchers caution that operation of a larger fan or installation in a very tight home could result in higher levels because depressurization is greater. The daily energy consumption for use of these appliances during the heating season was calculated to be 1.5 kilowatt hours or approximately 3% of the energy consumption in the study homes. The information collected in this collaborative field study indicates that the use of these particular ventilation systems has no significant effect on indoor air quality

  20. Numerical study of turbulent normal diffusion flame CH4-air stabilized by coaxial burner

    Directory of Open Access Journals (Sweden)

    Riahi Zouhair

    2013-01-01

    Full Text Available The practical combustion systems such as combustion furnaces, gas turbine, engines, etc. employ non-premixed combustion due to its better flame stability, safety, and wide operating range as compared to premixed combustion. The present numerical study characterizes the turbulent flame of methane-air in a coaxial burner in order to determine the effect of airflow on the distribution of temperature, on gas consumption and on the emission of NOx. The results in this study are obtained by simulation on FLUENT code. The results demonstrate the influence of different parameters on the flame structure, temperature distribution and gas emissions, such as turbulence, fuel jet velocity, air jet velocity, equivalence ratio and mixture fraction. The lift-off height for a fixed fuel jet velocity is observed to increase monotonically with air jet velocity. Temperature and NOx emission decrease of important values with the equivalence ratio, it is maximum about the unity.

  1. A Study of Fatigue and Performance Considerations in Air Mobility Cargo Aircrews Flying Transatlantic Missions

    National Research Council Canada - National Science Library

    Levin, Julian

    1997-01-01

    The U.S. Air Force Air Mobility Command (AMC) is responsible for movement of supplies and personnel, air refueling operations and air evacuation operations throughout the world in support of the United States' national interest...

  2. Influence of urban vegetation on air pollution and noise exposure - A case study in Gothenburg, Sweden.

    Science.gov (United States)

    Klingberg, Jenny; Broberg, Malin; Strandberg, Bo; Thorsson, Pontus; Pleijel, Håkan

    2017-12-01

    Air pollution levels (NO 2 , PAHs, O 3 ) were investigated, before (BLE) and after (ALE) leaf emergence, in the urban landscape of Gothenburg, Sweden. The aims were to study the 1) spatial and temporal variation in pollution levels between urban green areas, 2) effect of urban vegetation on air pollution levels at the same distance from a major emission source (traffic route), 3) improvement of urban air quality in urban parks compared to adjacent sites near traffic, 4) correlation between air pollution and noise in a park. O 3 varied little over the urban landscape. NO 2 varied strongly and was higher in situations strongly influenced by traffic. Four PAH variables were included: total PAH, total particle-bound PAH, the quantitatively important gaseous phenanthrene and the highly toxic particle-bound benzo(a)pyrene. The variation of PAHs was similar to NO 2 , but for certain PAHs the difference between highly and less polluted sites was larger than for NO 2 . At a vegetated site, NO 2 and particulate PAH levels were lower than at a non-vegetated site at a certain distance from a busy traffic route. This effect was significantly larger ALE compared to BLE for NO 2 , indicating green leaf area to be highly significant factor for air quality improvement. For particulate PAHs, the effect was similar BLE and ALE, indicating that tree bark and branches also could be an important factor in reducing air pollution. Parks represented considerably cleaner local environments (park effect), which is likely to be a consequence of both a dilution (distance effect) and deposition. Noise and air pollution (NO 2 and PAH) levels were strongly correlated. Comparison of noise levels BLE and ALE also showed that the presence of leaves significantly reduced noise levels. Our results are evidence that urban green spaces are beneficial for urban environmental quality, which is important to consider in urban planning. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Rancang Bangun dan Studi Eksperimen Alat Penukar Panas untuk Memanfaatkan Energi Refrigerant Keluar Kompresor AC sebagai Pemanas Air pada ST/D=8 dengan Variasi Volume Air

    Directory of Open Access Journals (Sweden)

    Fajri Chairbowo

    2017-01-01

    Full Text Available Abstrak­- Kebutuhan masyarakat terhadap air hangat semakin meningkat. Hal itu disebabkan air hangat mempunyai berbagai manfaat. Air hangat efektif dalam melarutkan lemak ataupun sabun, serta air hangat dapat melancarkan peredaran darah manusia ketika digunakan. Demi efisiensi dalam penggunaan energi, penelitian yang dilakukan tentang pemanfaatan panas buang dari sistem refrigerasi.. Sebelum panas dibuang ke lingkungan, water heater ditambahkan oleh penulis ke sistem refrigerasi yang peletakkannya sesudah proses kompresi. Dimana water heater akan mengambil kalor dari refrigeran pemanas yang melintas sesudah dari kompresor. Sistem refrigerasi yang digunakan mempunyai daya  1 HP (746 Watt. Dalam penelitian ini sudah ditetapkan diameter tube dari water heater adalah 1 cm dengan jarak transversal setiap tube 8 cm, fluida yang mengalir di dalam tube adalah R-22 dan fluida diam yang berada di dalam tangki adalah air. Langkah awal dari penelitian ini  adalah melakukan pengujian  sistem AC split untuk mendapatkan data-data yang dibutuhkan dalam perancangan water heater. Tahap selanjutnya adalah studi numerik dimana studi numerik dilakukan secara dua dimensi dengan kondisi steady, incompressible, dan laminar dengan prinsip Computational Fluid Dynamics (CFD, menggunakan perangkat lunak GAMBIT 2.4.6 untuk tahap pembuatan domain dan disimulasikan dengan perangkat lunak FLUENT 6.3.26. Tahap terakhir adalah eksperimen yang bertujuan untuk mengetahui water heater yang dibuat sesuai dengan rancangan penulis. Kemudian water heater yang sudah dibuat, dipasang ke sistem AC split. Pada tahap eksperimen, penulis melakukan variasi terhadap volume air di tangki, yaitu 75 liter, 85 liter dan 100 liter. Hasil dari simulasi numerik menunjukkan fenomena perpindahan panas pada water heater, yang berupa kontur temperatur, kontur kecepatan dan velocity vector dalam bentuk dua dimensi tampak samping water heater. Hasil dari studi eksperimen ini menunjukkan nilai

  4. Remediation of Chlorinated Solvent Plumes Using In-Situ Air Sparging—A 2-D Laboratory Study

    Directory of Open Access Journals (Sweden)

    Jeffrey A. Adams

    2011-06-01

    Full Text Available In-situ air sparging has evolved as an innovative technique for soil and groundwater remediation impacted with volatile organic compounds (VOCs, including chlorinated solvents. These may exist as non-aqueous phase liquid (NAPL or dissolved in groundwater. This study assessed: (1 how air injection rate affects the mass removal of dissolved phase contamination, (2 the effect of induced groundwater flow on mass removal and air distribution during air injection, and (3 the effect of initial contaminant concentration on mass removal. Dissolved-phase chlorinated solvents can be effectively removed through the use of air sparging; however, rapid initial rates of contaminant removal are followed by a protracted period of lower removal rates, or a tailing effect. As the air flow rate increases, the rate of contaminant removal also increases, especially during the initial stages of air injection. Increased air injection rates will increase the density of air channel formation, resulting in a larger interfacial mass transfer area through which the dissolved contaminant can partition into the vapor phase. In cases of groundwater flow, increased rates of air injection lessened observed downward contaminant migration effect. The air channel network and increased air saturation reduced relative hydraulic conductivity, resulting in reduced groundwater flow and subsequent downgradient contaminant migration. Finally, when a higher initial TCE concentration was present, a slightly higher mass removal rate was observed due to higher volatilization-induced concentration gradients and subsequent diffusive flux. Once concentrations are reduced, a similar tailing effect occurs.

  5. Field Study on Humidification Performance of a Desiccant Air-Conditioning System Combined with a Heat Pump

    Directory of Open Access Journals (Sweden)

    Koichi Kawamoto

    2016-01-01

    Full Text Available A desiccant air-conditioning system was developed as a latent-load-processing air conditioner in a dedicated outdoor air system during the summer. This study investigated the application of this air-conditioning system to humidification during the winter without using make-up water, thereby eliminating the cause of microbial contamination in air-conditioning systems. The experiments were conducted with a system used for summer applications to determine the feasibility of adsorbing vapor from outdoor air and supplying it to an indoor space. The humidification performance, energy efficiency, and operating conditions were examined. Although the conditions were subpar because the experiments were performed with an actual dedicated outdoor air system, the results showed that it is possible to supply air with a minimum humidity ratio of 5.8 g/kg dry air (DA when the humidity ratio of outdoor air ranges from 1.8 to 2.3 g/kg DA. The minimum humidification performance required for a dedicated outdoor air system was achieved by increasing the airflow rate of the moisture-adsorption side to 2–3 times that of the humidification side. In addition, air leaking from the moisture-adsorption side to the humidification side, improving the mechanical structure, such as by the insulation of the moisture-adsorption side, and an efficient operating method were examined for humidification during the winter.

  6. Ambient air pollution the risk of stillbirth: A prospective birth cohort study in Wuhan, China.

    Science.gov (United States)

    Yang, Shaoping; Tan, Yafei; Mei, Hui; Wang, Fang; Li, Na; Zhao, Jinzhu; Zhang, Yiming; Qian, Zhengmin; Chang, Jen Jen; Syberg, Kevin M; Peng, Anna; Mei, Hong; Zhang, Dan; Zhang, Yan; Xu, Shunqing; Li, Yuanyuan; Zheng, Tongzhang; Zhang, Bin

    2018-04-01

    Recent studies suggest that ambient air pollution exposure during pregnancy is associated with stillbirth occurrence. However, the results on the associations between ambient air pollutants and stillbirths are inconsistent and little is known about the gestational timing of sensitive periods for the effects of ambient air pollutants exposure on stillbirth. This study aimed to examine whether exposure to high levels of ambient air pollutants in a Chinese population is associated with an increased risk of stillbirth, and determine the gestational period when the fetus is most susceptible. We conducted a population-based cohort study in Wuhan, China, involving 95,354 births between June 10, 2011 and June 9, 2013. The exposure assessments were based on the daily mean concentrations of air pollutants obtained from the exposure monitor nearest to the pregnant women's residence. Logistic regression analyses were performed to determine the associations between stillbirths and exposure to each of the air pollutants at different pregnancy periods with adjustment for confounding factors. Stillbirth increased with a 10 μg/m 3 increase in particulate matter 2.5 (PM 2.5 ) in each stage of pregnancy, and a significant association between carbon monoxide (CO) exposure and stillbirth was found during the third trimester (adjusted odds ratio (aOR): 1.01, 95% confidence interval (CI): 1.00-1.01) and in the entire pregnancy (aOR: 1.18, 95% CI: 1.04-1.34). Furthermore, an increased risk of stillbirth in the third trimester was associated with a 10 μg/m 3 increase in PM 10 (aOR: 1.08, 95% CI: 1.04-1.11), nitrogen dioxide (NO 2 ) (aOR: 1.13, 95% CI: 1.07-1.21) and sulfur dioxide (SO 2 ) (aOR: 1.26, 95% CI: 1.16-1.35). However, no positive association was observed between ozone exposure and stillbirth. In the two-pollutant models, PM 2.5 and CO exposures were found to be consistently associated with stillbirth. Our study revealed that exposure to high levels of PM 2.5 , PM 10 , SO 2

  7. A case study of air quality - Pesticides and odorous phytochemicals on Kauai, Hawaii, USA.

    Science.gov (United States)

    Wang, Jun; Boesch, Robert; Li, Qing X

    2017-12-01

    This study was conducted after a series of incidences occurred at Waimea Canyon Middle School on Kauai, Hawaii. Some students and staff members exhibited symptoms such as throat irritation, tearing, and dizziness. These symptoms could be associated with natural causes or human activities, which include exposures to pesticides and odorous phytochemicals. At the time of the occurrences, Cleome gynandra (known locally as stinkweed) was growing in the fields near the school and might be a potential cause of the reported symptoms. This work was designed to study pesticides and phytochemicals in ambient air around Waimea Canyon Middle School in comparison with other locations on Kauai. Among many chemicals, top 29 were selected for the analysis of stinkweed-emitted chemicals in a chamber study. One out of the 29 chemicals was methyl isothiocyanate (MITC) that is a highly foul-smelling, noxious chemical at high concentrations. Approximately half of the 29 chemicals produced by stinkweed and trace amounts of five pesticides were detected in indoor and outdoor air samples collected from the passive and high volume air samplers. The average concentrations of MITC in Waimea outdoor air during daytime and nighttime were 13.1 and 5.6 ng m -3 , respectively. The average concentrations of the five pesticides DDTs, HCHs, chlorpyrifos, bifenthrin, and metolachlor in Waimea outdoor air were respectively 2.5, 2.3, 35, 43, and 23 ng m -3 during daytime and 2.4, 1.7, 33, 29, and 19 ng m -3 during nighttime. The concentrations of the pesticide and phytochemicals found in air on Kauai were below health concern levels. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Air contamination for predicting wound contamination in clean surgery: A large multicenter study.

    Science.gov (United States)

    Birgand, Gabriel; Toupet, Gaëlle; Rukly, Stephane; Antoniotti, Gilles; Deschamps, Marie-Noelle; Lepelletier, Didier; Pornet, Carole; Stern, Jean Baptiste; Vandamme, Yves-Marie; van der Mee-Marquet, Nathalie; Timsit, Jean-François; Lucet, Jean-Christophe

    2015-05-01

    The best method to quantify air contamination in the operating room (OR) is debated, and studies in the field are controversial. We assessed the correlation between 2 types of air sampling and wound contaminations before closing and the factors affecting air contamination. This multicenter observational study included 13 ORs of cardiac and orthopedic surgery in 10 health care facilities. For each surgical procedure, 3 microbiologic air counts, 3 particles counts of 0.3, 0.5, and 5 μm particles, and 1 bacteriologic sample of the wound before skin closure were performed. We collected data on surgical procedures and environmental characteristics. Of 180 particle counts during 60 procedures, the median log10 of 0.3, 0.5, and 5 μm particles was 7 (interquartile range [IQR], 6.2-7.9), 6.1 (IQR, 5.4-7), and 4.6 (IQR, 0-5.2), respectively. Of 180 air samples, 50 (28%) were sterile, 90 (50%) had 1-10 colony forming units (CFU)/m(3) and 40 (22%) >10 CFU/m(3). In orthopedic and cardiac surgery, wound cultures at closure were sterile for 24 and 9 patients, 10 and 11 had 1-10 CFU/100 cm(2), and 0 and 6 had >10 CFU/100 cm(2), respectively (P air microbial counts (P contamination (P = .22). This study suggests that particle counting is a good surrogate of airborne microbiologic contamination in the OR. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  9. SU-F-T-656: Monte Carlo Study On Air Activation Around a Medical Electron Linac

    International Nuclear Information System (INIS)

    Horst, F; Fehrenbacher, G; Zink, K

    2016-01-01

    Purpose: In high energy photon therapy, several radiation protection issues result from photonuclear reactions. The activation of air - directly by photonuclear reactions as well as indirectly by capture of photoneutrons generated inside the linac head - is a major point of concern for the medical staff. The purpose of this study was to estimate the annual effective dose to medical workers due to activated air around a medical high energy electron linac by means of Monte Carlo simulations. Methods: The treatment head of a Varian Clinac in 18 MV-X mode as well as the surrounding concrete bunker were modeled and the radiation transport was simulated using the Monte Carlo code FLUKA, starting from the primary electron striking the bremsstrahlung target. The activation yields in air from photo-disintegration of O-16 and N-14 nuclei as well as from neutron capture on Ar-40 nuclei were obtained from the simulations. The activation build-up, radioactive decay and air ventilation were studied using a mathematical model. The annual effective dose to workers was estimated by using published isotope specific conversion factors. Results: The oxygen and nitrogen activation yields were in contrast to the argon activation yield found to be field size dependent. The impact of the treatment room ventilation on the different air activation products was investigated and quantified. An estimate with very conservative assumptions gave an annual effective dose to workers of < 1 mSv/a. Conclusion: From the results of this study it can be concluded that the contribution of air activation to the radiation exposure to medical workers should be negligible in modern photon therapy, especially when it is compared to the dose due to prompt neutrons and the activation of heavy solid materials such as the jaws and the collimators inside the linac head.

  10. Exposure to traffic noise and air pollution and risk for febrile seizure: a cohort study.

    Science.gov (United States)

    Hjortebjerg, Dorrit; Nybo Andersen, Anne-Marie; Ketzel, Matthias; Raaschou-Nielsen, Ole; Sørensen, Mette

    2018-03-25

    Objectives Exposure to traffic noise and air pollution is suspected to increase susceptibility to viral infections - the main triggering factor for febrile seizures. No studies have examined these two exposures in relation to febrile seizures. We aimed to investigate whether exposure to road traffic noise and air pollution are associated with risk of febrile seizures in childhood. Methods From our study base of 51 465 singletons from a national birth cohort, we identified 2175 cases with febrile seizures using a nationwide registry. Residential address history from conception to six years of age were found in national registers, and road traffic noise (L den ) and air pollution (NO 2 ) were modeled for all addresses. Analyses were done using Cox proportional hazard model with adjustment for potential confounders, including mutual exposure adjustment. Results An interquartile range (IQR) increase in childhood exposure to road traffic noise and air pollution was associated with an 11% [incidence rate ratio (IRR) 1.11, 95% confidence interval (CI) 1.04-1.19) and 5% (IRR 1.05, 95% CI 1.02-1.07) higher risk for febrile seizures, respectively, after adjustment for potential confounders. Weaker tendencies were seen for pregnancy exposure. In models with mutual exposure adjustment, the estimates were slightly lower, with IRR of 1.08 (95% CI 1.00-1.16) and 1.03 (95% CI 0.99-1.06) per IQR increase in childhood exposure to road traffic noise and air pollution, respectively. Conclusions This study suggests that residential exposure to road traffic noise and air pollution is associated with higher risk for febrile seizures.

  11. SU-F-T-656: Monte Carlo Study On Air Activation Around a Medical Electron Linac

    Energy Technology Data Exchange (ETDEWEB)

    Horst, F [Institute of Medical Physics and Radiation Protection, University of Applied Sciences, Giessen (Germany); GSI Helmholtz Centre for Heavy Ion Research, Darmstadt (Germany); Fehrenbacher, G [GSI Helmholtz Centre for Heavy Ion Research, Darmstadt (Germany); Zink, K [Institute of Medical Physics and Radiation Protection, University of Applied Sciences, Giessen (Germany); University Hospital Giessen-Marburg, Marburg (Germany)

    2016-06-15

    Purpose: In high energy photon therapy, several radiation protection issues result from photonuclear reactions. The activation of air - directly by photonuclear reactions as well as indirectly by capture of photoneutrons generated inside the linac head - is a major point of concern for the medical staff. The purpose of this study was to estimate the annual effective dose to medical workers due to activated air around a medical high energy electron linac by means of Monte Carlo simulations. Methods: The treatment head of a Varian Clinac in 18 MV-X mode as well as the surrounding concrete bunker were modeled and the radiation transport was simulated using the Monte Carlo code FLUKA, starting from the primary electron striking the bremsstrahlung target. The activation yields in air from photo-disintegration of O-16 and N-14 nuclei as well as from neutron capture on Ar-40 nuclei were obtained from the simulations. The activation build-up, radioactive decay and air ventilation were studied using a mathematical model. The annual effective dose to workers was estimated by using published isotope specific conversion factors. Results: The oxygen and nitrogen activation yields were in contrast to the argon activation yield found to be field size dependent. The impact of the treatment room ventilation on the different air activation products was investigated and quantified. An estimate with very conservative assumptions gave an annual effective dose to workers of < 1 mSv/a. Conclusion: From the results of this study it can be concluded that the contribution of air activation to the radiation exposure to medical workers should be negligible in modern photon therapy, especially when it is compared to the dose due to prompt neutrons and the activation of heavy solid materials such as the jaws and the collimators inside the linac head.

  12. Measurement error in epidemiologic studies of air pollution based on land-use regression models.

    Science.gov (United States)

    Basagaña, Xavier; Aguilera, Inmaculada; Rivera, Marcela; Agis, David; Foraster, Maria; Marrugat, Jaume; Elosua, Roberto; Künzli, Nino

    2013-10-15

    Land-use regression (LUR) models are increasingly used to estimate air pollution exposure in epidemiologic studies. These models use air pollution measurements taken at a small set of locations and modeling based on geographical covariates for which data are available at all study participant locations. The process of LUR model development commonly includes a variable selection procedure. When LUR model predictions are used as explanatory variables in a model for a health outcome, measurement error can lead to bias of the regression coefficients and to inflation of their variance. In previous studies dealing with spatial predictions of air pollution, bias was shown to be small while most of the effect of measurement error was on the variance. In this study, we show that in realistic cases where LUR models are applied to health data, bias in health-effect estimates can be substantial. This bias depends on the number of air pollution measurement sites, the number of available predictors for model selection, and the amount of explainable variability in the true exposure. These results should be taken into account when interpreting health effects from studies that used LUR models.

  13. A comparison study of exploding a Cu wire in air, water, and solid powders

    Science.gov (United States)

    Han, Ruoyu; Wu, Jiawei; Ding, Weidong; Zhou, Haibin; Qiu, Aici; Wang, Yanan

    2017-11-01

    In this paper, an experimental study on exploding a copper wire in air, water, incombustible powders, and energetic materials is performed. We examined the effects of the surrounding media on the explosion process and its related phenomena. Experiments were first carried out with copper wire explosions driven by microsecond timescale pulsed currents in air, water, and the half-half case. Then, the copper wires were exploded in air, water, SiO2 powders, quartz sand, NaCl powders, and energetic-material cylinders, respectively. Our experimental results indicated that the explosion process was significantly influenced by the surrounding media, resulting in noticeable differences in energy deposition, optical emission, and shock waves. In particular, incombustible powders could throttle the current flow completely when a fine wire was adopted. We also found that an air or incombustible-powder layer could drastically attenuate the shock wave generated by a wire explosion. As for energetic-material loads, obvious discrepancies were found in voltage/current waveforms from vaporization when compared with a wire explosion in air/water, which meant the metal vapor/liquid drops play a significant role in the ignition process.

  14. STUDY ON THE CONTENT OF SEDIMENT PARTICLES IN THE AIR AROUND TG. JIU TOWN

    Directory of Open Access Journals (Sweden)

    Ramona Violeta Cazalbașu

    2016-12-01

    Full Text Available One of the most important problems of the modern era is the air pollution. This phenomenon, highly complex, has become the focus of several international organizations since the consequences of air pollution are felt outside the country borders. By and large wecan speak of a regional pollution, which consists of atmospheric contamination by waste or by products liquids, solids gas, threatening the health of people, plants and animals or which can attack materials, reduce visibility and cause unpleasant odors. On a planetary scale, the elimination or accumulation in the atmosphere of certain products, leads to irreparable consequences on the planet's natural balance: ozone depletion and global warming of the atmosphere. This paper presents the study on the sedimentparticles in the air in Tg-Jiu. Determination of particulate matter from the air was done according to Standard no. 10195 / 75.Air purity.Determination of settled particles. In 2014 no exceeding of the maximum allowable concentration of sediment particles has been found in the four sampling points and in2015, out of a total of 60 measurements in four sampling points only one was above the maximum permissible concentration

  15. Preliminary study of the distribution of gaseous mercury species in the air of Guiyang city, China

    Science.gov (United States)

    Shang, L.; Feng, X.; Zheng, W.; Yan, H.

    2003-05-01

    Total gaseous mercury (TGM) in ambient air consists of Hg^0 and reactive gaseous mercury (RGM) in general. Although RGM only constitutes a small portion of TGM in the air, it contributes the most to both dry and wet deposition of mercury from the atmosphere. TGM and RGM concentrations in ambient air at one site of Guiyang City were determined in March 2002. TGM concentrations were monitored using an automated mercury vapor analyzer Tekran2537A, and RGM in ambient air was sampled using KCI coated tubular denuders. The sampled RGM denuders were analyzed using thermal desorption coupled with CVAFS detection. The average concentrations of TGM and RGM are 7.09 ng m^{-3} and 37.5pg m^{-3} respectively during the sampling period. The primary anthropogenic source for both Hg^0 and RGM is coal combustion in the study area. TGM concentrations are significantly elevated comparing to the global background values, whereas RGM concentrations are only slightly higher than the reported values in remote areas in Europe and US. RGM only constitutes 0.5% ofTGM in the air at the sampling period. There is a significant negative correlation between RGM concentration and relative humidity (RH), with a coefficient correlation of 0.39 (αRGM concentrations observed.

  16. Application of a 2D air flow model to soil vapor extraction and bioventing case studies

    International Nuclear Information System (INIS)

    Mohr, D.H.; Merz, P.H.

    1995-01-01

    Soil vapor extraction (SVE) is frequently the technology of choice to clean up hydrocarbon contamination in unsaturated soil. A two-dimensional air flow model provides a practical tool to evaluate pilot test data and estimate remediation rates for soil vapor extraction systems. The model predictions of soil vacuum versus distance are statistically compared to pilot test data for 65 SVE wells at 44 sites. For 17 of 21 sites where there was asphalt paving, the best agreement was obtained for boundary conditions with no barrier to air flow at the surface. The model predictions of air flow rates and stream lines around the well allow an estimate of the gasoline removal rates by both evaporation and bioremediation. The model can be used to quickly estimate the effective radius of influence, defined here as the maximum distance from the well where there is enough air flow to remove the contaminant present within the allowable time. The effective radius of influence is smaller than a radius of influence defined by soil vacuum only. For a case study, in situ bioremediation rates were estimated using the air flow model and compared to independent estimates based on changes in soil temperature. These estimate bioremediation rates for heavy fuel oil ranged from 2.5 to 11 mg oil degraded per kg soil per day, in agreement with values in the literature

  17. Air pollution and decreased semen quality: A comparative study of Chongqing urban and rural areas

    International Nuclear Information System (INIS)

    Zhou, Niya; Cui, Zhihong; Yang, Sanming; Han, Xue; Chen, Gangcai; Zhou, Ziyuan; Zhai, Chongzhi; Ma, Mingfu; Li, Lianbing; Cai, Min; Li, Yafei; Ao, Lin; Shu, Weiqun; Liu, Jinyi; Cao, Jia

    2014-01-01

    To investigate the association and effects of air pollution level on male semen quality in urban and rural areas, this study examines the outdoor concentrations of particulate matter (PM 10 ), sulfur dioxide (SO 2 ), nitrous dioxide (NO 2 ) and semen quality outcomes for 1346 volunteers in both urban and rural areas in Chongqing, China. We found the urban area has a higher pollution level than the rural area, contrasted with better semen quality in the rural residents, especially for sperm morphology and computer assistant semen analysis (CASA) motility parameters. A multivariate linear regression analysis demonstrates that concentrations of PM 10 , SO 2 , and NO 2 significantly and negatively are associated with normal sperm morphology percentage (P  10 , SO 2 , and NO 2 in urban ambient air may account for worse semen quality in urban males. - Highlights: • We investigate the distributions of PM 10 , SO 2 and NO 2 in urban and rural areas in Chongqing, China. • We explore the associations of air pollution and male semen quality. • The concentrations of PM 10 , SO 2 , and NO 2 are significantly higher in urban areas. • Median values of some semen quality parameters in rural male were higher than urban male. • PM 10 , SO 2 , and NO 2 were negatively associated with semen quality parameters. - Air pollution is higher in the urban area while there is better semen quality in rural males. Polluted air may thus account for worse semen quality in urban males

  18. Theoretical and numerical studies of transonic flow of moist air around a thin airfoil

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jang-Chang [School of Mechanical Engineering, Andong National University, Kyongbuk (Korea); Rusak, Zvi [Department of Mechanical, Aerospace, and Nuclear Engineering, Rensselaer Polytechnic Institute, Troy, NY (United States)

    2002-07-01

    Numerical studies of a two-dimensional and steady transonic flow of moist air around a thin airfoil with condensation are presented. The computations are guided by a recent transonic small-disturbance (TSD) theory of Rusak and Lee (2000) on this topic. The asymptotic model provides a simplified framework to investigate the changes in the flow field caused by the heat addition from a nonequilibrium process of condensation of water vapor in the air by homogeneous nucleation. An iterative method which is based on a type-sensitive difference scheme is applied to solve the governing equations. The results demonstrate the similarity rules for transonic flow of moist air and the effects of energy supply by condensation on the flow behavior. They provide a method to formulate various cases with different flow properties that have a sufficiently close behavior and that can be used in future computations, experiments, and design of flow systems operating with moist air. Also, the computations show that the TSD solutions of moist air flows represent the essence of the flow character computed from the inviscid fluid flow equations. (orig.)

  19. Effect of Air Pollution on the Emergency Admissions of Cardiovascular and Respiratory Patients, Using the Air Quality Model: A Study in Tehran, 2005-2014

    Directory of Open Access Journals (Sweden)

    Majid Kermani

    2016-04-01

    Full Text Available Background: Air pollution is one of the most important factors threatening the health of citizens. It increases the prevalence of cardiovascular and respiratory diseases as well as emergency admissions to hospitals in the polluted metropolitan cities. The present study was conducted using Air Quality (AirQ model and aimed to investigate the effects of air pollution on the number of emergency cardiovascular and respiratory patients admissions in Tehran hospitals during 2005-2014. Materials and Methods: This was cross-sectional study. First, the needed hourly information was received from the Bureau of Air Quality Control, and the Environmental Protection Agency of Tehran City. Then, the information was validated according to WHO criteria, and the statistical indicators and the stages required to quantify the harmful effects of air pollutants were calculated by using appropriate application. Results: According to the results, the number of cases admitted to the emergency ward of hospitals due to heart diseases (by exposure to particulate matter during the years 2005 to 2014 were respectively 1797, 1280, 1766, 1980, 2132, 2703, 2389, 2594, 2158, and 2291 cases, totaling 20990 persons, and for respiratory diseases (due to exposure to particulate matter during the same years were respectively 4643, 3301, 4650, 5117, 5511, 6999, 6180, 6452, 5577, and 5922 cases, totaling 54352 people. Also, the number of cases admitted to the emergency wards of hospitals due to chronic obstructive pulmonary disease caused by exposure to emissions of pollutants such as sulfur dioxide, nitrogen dioxide, and ozone were respectively, 1806, 2454, and 2941 cases. Conclusion: Air pollution in Tehran increases the load of emergency visits to hospitals and increases the risk of respiratory and heart diseases. Therefore, measures to reduce and control air pollution and to prepare, equip, and mobilize hospitals, particularly emergency wards, are among important priorities that

  20. Stroke and Long-Term Exposure to Outdoor Air Pollution From Nitrogen Dioxide A Cohort Study

    DEFF Research Database (Denmark)

    Andersen, Zorana Jovanovic; Kristiansen, Luise Cederkvist; Andersen, Klaus K.

    2012-01-01

    Background and Purpose-Years of exposure to tobacco smoke substantially increase the risk for stroke. Whether long-term exposure to outdoor air pollution can lead to stroke is not yet established. We examined the association between long-term exposure to traffic-related air pollution and incident...... and fatal stroke in a prospective cohort study.Methods-We followed 57 053 participants of the Danish Diet, Cancer and Health cohort in the Hospital Discharge Register for the first-ever hospital admission for stroke (incident stroke) between baseline (1993-1997) and 2006 and defined fatal strokes as death...

  1. Air Pollution with Heavy Metals and Radionuclides in Slovakia Studied by the Moss Biomonitoring Technique

    CERN Document Server

    Florek, M; Mankovska, B; Oprea, K; Pavlov, S S; Steinnes, E; Sykora, I

    2001-01-01

    Applying the moss biomonitoring technique to air pollution studies in Slovakia, heavy metals, rare-earth elements, actinides (U and Th) were determined in 86 moss samples from the European moss survey 2000 by means of epithermal neutron activation analysis at the IBR-2 reactor (Dubna). Such elements as In, Cu, Cd, Hg and Pb were determined by AAS in the Forest Research Institute, Zvolen (Slovakia). The results of measurement of the natural radionuclides ^{210}Pb, ^{7}Be, ^{137}Cs and ^{40}K in 11 samples of moss are also reported. A comparison with the results from moss surveys 1991 and 1995 revealed previously unknown tendencies of air pollution in the examined areas.

  2. Experimental Study on Indoor Air Cleaning Technique of Nano-Titania Catalysis Under Plasma Discharge

    International Nuclear Information System (INIS)

    Gao Deli; Yang Xuechang; Zhou Fei; Wu Yuhuang

    2008-01-01

    In this study, a new technique of air cleaning by plasma combined with catalyst was proposed, which consisted of electrostatic precipitation, volatile organic compounds (VOCs) decomposition and sterilization. A novel indoor air purifier based on this technique was adopted. The experimental results showed that formaldehyde decomposition by the plasma-catalyst hybrid system was more efficient than that by plasma only. Positive discharge was better than negative discharge in formaldehyde removal. Meanwhile, the outlet concentration of ozone byproduct was effectively reduced by the nano-titania catalyst.

  3. A comparative study of turbulence models for dissolved air flotation flow analysis

    International Nuclear Information System (INIS)

    Park, Min A; Lee, Kyun Ho; Chung, Jae Dong; Seo, Seung Ho

    2015-01-01

    The dissolved air flotation (DAF) system is a water treatment process that removes contaminants by attaching micro bubbles to them, causing them to float to the water surface. In the present study, two-phase flow of air-water mixture is simulated to investigate changes in the internal flow analysis of DAF systems caused by using different turbulence models. Internal micro bubble distribution, velocity, and computation time are compared between several turbulence models for a given DAF geometry and condition. As a result, it is observed that the standard κ-ε model, which has been frequently used in previous research, predicts somewhat different behavior than other turbulence models

  4. A study of physical and chemical forms of 7BE in air particulates of Damascus city

    International Nuclear Information System (INIS)

    Al-Masri, M.S.; Al-Kharfan, K.; Hasan, M.

    1999-01-01

    Physical and chemical forms of 7B e in air particulates of Damascus city during 1997-1998 have been studied. Results have shown that 7B e is mainly attached to particulates having 0.95 μ diameters. In addition, a difference between 7B e concentrations in air particulates collected by TSP filters and PM10 filters has been observed. This difference could be used to evaluate the amount of 7B e due to air suspension. Moreover, results have also shown that the chemical forms of 7B e differ from one month to another according to weather conditions, 7B e was found to be in an exchangeable form in wet months and undissolved form in dry months. (author)

  5. THERMAL COMFORT STUDY OF AN AIR-CONDITIONED DESIGN STUDIO IN TROPICAL SURABAYA

    Directory of Open Access Journals (Sweden)

    Agus Dwi Hariyanto

    2005-01-01

    Full Text Available This paper evaluates the current thermal comfort condition in an air-conditioned design studio using objective measurement and subjective assessment. Objective measurement is mainly to quantify the air temperature, MRT, relative humidity, and air velocity. Subjective assessment is conducted using a questionnaire to determine the occupants thermal comfort sensations and investigate their perception of the thermal comfort level. A design studio in an academic institution in Surabaya was chosen for the study. Results show that more than 80% of the occupants accepted the indoor thermal conditions even though both the environmental and comfort indices exceeded the limit of the standard (ASHRAE Standard 55 and ISO 7730. In addition, non-uniformity of spatial temperature was present in this studio. Some practical recommendations were made to improve the thermal comfort in the design studio.

  6. Air Quality Scoping Study for Ash Meadows National Wildlife Refuge, Nevada (EMSI April 2007)

    Energy Technology Data Exchange (ETDEWEB)

    Engelbrecht, Johann; Kavouras, Ilias; Campbell, Dave; Campbell, Scott; Kohl, Steven; Shafer, David

    2007-04-01

    The Desert Research Institute (DRI) is performing a scoping study as part of the U.S.Department of Energy’s Yucca Mountain Environmental Monitoring Systems Initiative (EMSI). The main objective is to obtain baseline air quality information for Yucca Mountain and an area surrounding the Nevada Test Site (NTS). Air quality and meteorological monitoring and sampling equipment housed in a mobile trailer (shelter) is collecting data at seven sites outside the NTS, including Ash Meadows National Wildlife Refuge, Sarcobatus Flat, Beatty, Rachel, Caliente, Pahranagat National Wildlife Refuge, and Crater Flat, and at four sites on the NTS. The trailer is stationed at any one site for approximately eight weeks at a time. Letter reports provide summaries of air quality and meteorological data, on completion of each site’s sampling program.

  7. Does consideration of larger study areas yield more accurate estimates of air pollution health effects?

    DEFF Research Database (Denmark)

    Pedersen, Marie; Siroux, Valérie; Pin, Isabelle

    2013-01-01

    BACKGROUND: Spatially-resolved air pollution models can be developed in large areas. The resulting increased exposure contrasts and population size offer opportunities to better characterize the effect of atmospheric pollutants on respiratory health. However the heterogeneity of these areas may......: Simulations indicated that adjustment for area limited the bias due to unmeasured confounders varying with area at the costs of a slight decrease in statistical power. In our cohort, rural and urban areas differed for air pollution levels and for many factors associated with respiratory health and exposure....... Area tended to modify effect measures of air pollution on respiratory health. CONCLUSIONS: Increasing the size of the study area also increases the potential for residual confounding. Our simulations suggest that adjusting for type of area is a good option to limit residual confounding due to area...

  8. Experimental and numerical study of flow deflection effects on electronic air-cooling

    International Nuclear Information System (INIS)

    Arfaoui, Ahlem; Ben Maad, Rejeb; Hammami, Mahmoud; Rebay, Mourad; Padet, Jacques

    2009-01-01

    This work present a numerical and experimental investigation of the influence of transversal flow deflector on the cooling of a heated block mounted on a flat plate. The deflector is inclined and therefore it guides the air flow to the upper surface of the block. This situation is simulating the air-cooling of a rectangular integrated circuit or a current converter mounted on an electronic board. The electronic component are assumed dissipating a low or medium heat flux (with a density lower than 5000 W/m 2 ), as such the forced convection air cooling without fan or heat sink is still sufficient. The study details the effects of the angle of deflector on the temperature and the heat transfer coefficient along the surface of the block and around it. The results of the numerical simulations and the InfraRed camera measurements show that the deviation caused by deflector may significantly enhance the heat transfer on the top face of block

  9. Experimental study of heat transfer and thermal performance with longitudinal fins of solar air heater

    Directory of Open Access Journals (Sweden)

    Foued Chabane

    2014-03-01

    Full Text Available The thermal performance of a single pass solar air heater with five fins attached was investigated experimentally. Longitudinal fins were used inferior the absorber plate to increase the heat exchange and render the flow fluid in the channel uniform. The effect of mass flow rate of air on the outlet temperature, the heat transfer in the thickness of the solar collector, and the thermal efficiency were studied. Experiments were performed for two air mass flow rates of 0.012 and 0.016 kg s−1. Moreover, the maximum efficiency values obtained for the 0.012 and 0.016 kg s−1 with and without fins were 40.02%, 51.50% and 34.92%, 43.94%, respectively. A comparison of the results of the mass flow rates by solar collector with and without fins shows a substantial enhancement in the thermal efficiency.

  10. Experimental study of heat transfer and thermal performance with longitudinal fins of solar air heater.

    Science.gov (United States)

    Chabane, Foued; Moummi, Noureddine; Benramache, Said

    2014-03-01

    The thermal performance of a single pass solar air heater with five fins attached was investigated experimentally. Longitudinal fins were used inferior the absorber plate to increase the heat exchange and render the flow fluid in the channel uniform. The effect of mass flow rate of air on the outlet temperature, the heat transfer in the thickness of the solar collector, and the thermal efficiency were studied. Experiments were performed for two air mass flow rates of 0.012 and 0.016 kg s(-1). Moreover, the maximum efficiency values obtained for the 0.012 and 0.016 kg s(-1) with and without fins were 40.02%, 51.50% and 34.92%, 43.94%, respectively. A comparison of the results of the mass flow rates by solar collector with and without fins shows a substantial enhancement in the thermal efficiency.

  11. Air-borne heavy metal contamination to dietary vegetables: a case study from India.

    Science.gov (United States)

    Pandey, J; Pandey, Richa; Shubhashish, K

    2009-12-01

    Contamination of edible parts of three dietary vegetables, Spinach (Spinacia oleracea L.), Radish (Raphanus sativus L.), and Tomato (Lycopersicon esculentum Mill.) by air-borne cadmium (Cd), chromium (Cr), copper (Cu), nickel (Ni), and lead (Pb) was determined using pot culture experiments at three sites in the city of Varanasi, India. The data revealed that although Cr and Cu in vegetables remained below their safe limits, about 68% of the total samples contained Cd, Ni, and Pb above their respective safe limits of 1.5, 1.5, and 2.5 μg g(-1). Site wise synchrony and air accumulation factor (AAF) indicated that atmospheric deposition was the main contributor of metal contamination to vegetables. The study suggests that if the present trends of atmospheric deposition are continued, air-borne heavy metals will contaminate the agricultural produce with long-term health implications.

  12. An experimental study of solar desalination using free jets and an auxiliary hot air stream

    Science.gov (United States)

    Eid, Eldesouki I.; Khalaf-Allah, Reda A.; Dahab, Mohamed A.

    2018-04-01

    An experimental study for a solar desalination system based on jet-humidification with an auxiliary perpendicular hot air stream was carried out at Suez city, Egypt 29.9668°N, 32.5498°E. The tests were done from May to October 2016. The effects of nozzles situations and nozzle diameter with and without hot air stream on fresh water productivity were monitored. The results show that; the lateral and downward jets from narrow nozzles have more productivities than other situations. The hot air stream has to be adapted at a certain flow rate to get high values of productivity. The system productivity is (5.6 L/m 2 ), the estimated cost is (0.030063 / L) and the efficiency is 32.8%.

  13. Ignition Study on a Rotary-valved Air-breathing Pulse Detonation Engine

    Science.gov (United States)

    Wu, Yuwen; Han, Qixiang; Shen, Yujia; Zhao, Wei

    2017-05-01

    In the present study, the ignition effect on detonation initiation was investigated in the air-breathing pulse detonation engine. Two kinds of fuel injection and ignition methods were applied. For one method, fuel and air was pre-mixed outside the PDE and then injected into the detonation tube. The droplet sizes of mixtures were measured. An annular cavity was used as the ignition section. For the other method, fuel-air mixtures were mixed inside the PDE, and a pre-combustor was utilized as the ignition source. At firing frequency of 20 Hz, transition to detonation was obtained. Experimental results indicated that the ignition position and initial flame acceleration had important effects on the deflagration-to-detonation transition.

  14. Effect of air pollution on peri-urban agriculture: a case study

    International Nuclear Information System (INIS)

    Agrawal, M.; Singh, B.; Rajput, M.; Marshall, F.; Bell, J.N.B.

    2003-01-01

    Peri-urban agriculture is vital for the urban populations of many developing countries. Increases in both industrialization and urbanization, and associated air pollution threaten urban food production and its quality. Six hour mean concentrations were monitored for SO 2 , NO 2 and O 3 and plant responses were measured in terms of physiological characteristics, pigment, biomass and yield. Parameter reductions in mung bean (Vigna radiata), palak (Beta vulgaris), wheat (Triticum aestivum) and mustard (Brassica compestris) grown within the urban fringes of Varanasi, India correlated directly with the gaseous pollutants levels. The magnitude of response involved all three gaseous pollutants at peri-urban sites; O 3 had more influence at a rural site. The study concluded that air pollution in Varanasi could negatively influence crop yield. - Urban air pollution has a negative impact on peri-urban agriculture

  15. Effect of air pollution on peri-urban agriculture: a case study

    Energy Technology Data Exchange (ETDEWEB)

    Agrawal, M.; Singh, B.; Rajput, M.; Marshall, F.; Bell, J.N.B

    2003-12-01

    Peri-urban agriculture is vital for the urban populations of many developing countries. Increases in both industrialization and urbanization, and associated air pollution threaten urban food production and its quality. Six hour mean concentrations were monitored for SO{sub 2}, NO{sub 2} and O{sub 3} and plant responses were measured in terms of physiological characteristics, pigment, biomass and yield. Parameter reductions in mung bean (Vigna radiata), palak (Beta vulgaris), wheat (Triticum aestivum) and mustard (Brassica compestris) grown within the urban fringes of Varanasi, India correlated directly with the gaseous pollutants levels. The magnitude of response involved all three gaseous pollutants at peri-urban sites; O{sub 3} had more influence at a rural site. The study concluded that air pollution in Varanasi could negatively influence crop yield. - Urban air pollution has a negative impact on peri-urban agriculture.

  16. Exploring the concept of compressed air energy storage (CAES) in lined rock caverns at shallow depth: A modeling study of air tightness and energy balance

    International Nuclear Information System (INIS)

    Kim, Hyung-Mok; Rutqvist, Jonny; Ryu, Dong-Woo; Choi, Byung-Hee; Sunwoo, Choon; Song, Won-Kyong

    2012-01-01

    Highlights: ► We carried out coupled thermodynamic, multiphase fluid flow and heat transport analysis. ► Coupled behavior associated with underground lined caverns for CAES was investigated. ► Air leakage could be reduced by controlling the permeability of concrete lining. ► Heat loss during compression would be gained back at subsequent decompression phase. -- Abstract: This paper presents a numerical modeling study of coupled thermodynamic, multiphase fluid flow and heat transport associated with underground compressed air energy storage (CAES) in lined rock caverns. Specifically, we explored the concept of using concrete lined caverns at a relatively shallow depth for which constructing and operation costs may be reduced if air tightness and stability can be assured. Our analysis showed that the key parameter to assure long-term air tightness in such a system was the permeability of both the concrete lining and the surrounding rock. The analysis also indicated that a concrete lining with a permeability of less than 1 × 10 −18 m 2 would result in an acceptable air leakage rate of less than 1%, with the operation pressure range between 5 and 8 MPa at a depth of 100 m. It was further noted that capillary retention properties and the initial liquid saturation of the lining were very important. Indeed, air leakage could be effectively prevented when the air-entry pressure of the concrete lining is higher than the operation air pressure and when the lining is kept at relatively high moisture content. Our subsequent energy-balance analysis demonstrated that the energy loss for a daily compression and decompression cycle is governed by the air-pressure loss, as well as heat loss by conduction to the concrete liner and surrounding rock. For a sufficiently tight system, i.e., for a concrete permeability of less than 1 × 10 −18 m 2 , heat loss by heat conduction tends to become proportionally more important. However, the energy loss by heat conduction can be

  17. The effects of outdoor air pollution on the respiratory health of Canadian children: A systematic review of epidemiological studies.

    Science.gov (United States)

    Rodriguez-Villamizar, Laura Andrea; Magico, Adam; Osornio-Vargas, Alvaro; Rowe, Brian H

    2015-01-01

    Outdoor air pollution is a global problem with serious effects on human health, and children are considered to be highly susceptible to the effects of air pollution. To conduct a comprehensive and updated systematic review of the literature reporting the effects of outdoor air pollution on the respiratory health of children in Canada. Searches of four electronic databases between January 2004 and November 2014 were conducted to identify epidemiological studies evaluating the effect of exposure to outdoor air pollutants on respiratory symptoms, lung function measurements and the use of health services due to respiratory conditions in Canadian children. The selection process and quality assessment, using the Newcastle-Ottawa Scale, were conducted independently by two reviewers. Twenty-seven studies that were heterogeneous with regard to study design, population, respiratory outcome and air pollution exposure were identified. Overall, the included studies reported adverse effects of outdoor air pollution at concentrations that were below Canadian and United States standards. Heterogeneous effects of air pollutants were reported according to city, sex, socioeconomic status and seasonality. The present review also describes trends in research related to the effect of air pollution on Canadian children over the past 25 years. The present study reconfirms the adverse effects of outdoor air pollution on the respiratory health of children in Canada. It will help researchers, clinicians and environmental health authorities identify the available evidence of the adverse effect of outdoor air pollution, research gaps and the limitations for further research.

  18. LONGITUDINAL STUDY OF SEMEN QUALITY AFTER INTERMITTENT EXPOSURE TO AIR POLLUTION

    Science.gov (United States)

    LONGITUDINAL STUDY OF SEMEN QUALITY AFTER INTERMITTENT EXPOSURE TO AIR POLLUTION. J. Rubes*, D. Zudova*, Veterinary Research Institute, Brno, CR, S.G. Selevan*, US EPA/ORD/NCEA, Washington, DC, D.P. Evenson, South Dakota State University, Brookings, SD, and S.D. Perreault, US ...

  19. Experimental studies on removal of airborne haloanisoles by non-thermal plasma air purifiers

    DEFF Research Database (Denmark)

    Fang, Lei; Hallam, David; Bermúdez, Raúl

    2016-01-01

    A laboratory study was conducted to test the performance of non-thermal plasma air purifiers on its removal effectiveness of two haloanisoles – 2,4,6-trichloroanisole (TCA) and 2,4,6-Tribromoanisole (TBA). TCA and TBA are the two major compounds found in wine cellars that can contaminate wine to ...

  20. Air pollution and respiratory health of children: the PEACE panel study in Prague, Czech Republic.

    NARCIS (Netherlands)

    Vondra, V.; Branis, M.; Reisova, M.; Maly, M.; Hoek, G.

    1998-01-01

    A multicentre study (Pollution Effects on Asthmatic Children in Europe (PEACE)) project investigated the relationship between the air pollution and daily variation of respiratory health in children with chronic respiratory symptoms. Data were collected on 66 children in Prague and 68 children in

  1. A comparative study on indoor air quality in a low cost and a green ...

    African Journals Online (AJOL)

    A study on Indoor Air Quality (IAQ) is important because people spend most of their time inside houses. IAQ was monitored in two different types of rural houses namely a low cost house and a “green” house built with pyramidal shape of roof in the rural area. Carbon monoxide (CO) and Carbon Dioxide (CO2) concentrations ...

  2. Experimental study of hard X-rays emitted from meter-scale positive discharges in air

    NARCIS (Netherlands)

    P.O. Kochkin (Pavlo); C.V. Nguyen; A. van Deursen (Arie); U. M. Ebert (Ute)

    2012-01-01

    textabstractWe investigate structure and evolution of long positive spark breakdown; and we study at which stage pulses of hard x-rays are emitted. Positive high-voltage pulses of standardized lightning impulse wave form of about 1 MV were applied to about 1 m of ambient air. The discharge evolution

  3. Investigation of indoor air quality at residential homes in Hong Kong - case study

    International Nuclear Information System (INIS)

    Shun Cheng Lee; Waiming Li; Chiohang Ao

    2002-01-01

    Indoor air quality (IAQ) has been a matter of public concern in Hong Kong. Recently, the Hong Kong Government has recognized the potential risk and problems related to indoor air pollution, and it is striving to establish IAQ objectives for different types of indoor environments. This study attempts to provide more information about the present IAQ of local resident flats. Air pollutants measured in this study included carbon dioxide (CO 2 ), respirable suspended particulate matter (PM 10 ), formaldehyde (HCHO), volatile organic compounds (VOCs) and airborne bacteria. The results of this study indicate that the 8-h average concentrations of CO 2 and PM 10 in the domestic kitchens investigated were 14% and 67% higher than those measured in the living rooms. The indoor air pollution caused by PM 10 was more serious in domestic kitchens than in living rooms as almost all of the kitchens investigated had higher indoor levels of PM 10 . The majority of the domestic living rooms and kitchens studied had average concentrations of airborne bacteria higher than 500CFU/m 3 . The mean total bacteria count recorded in kitchens was greater than that obtained in living rooms by 23%. In homes where occupants smoke, the negative impact of benzene, toluene and m,p-xylene on the IAQ was greatly enhanced. The use of liquefied petroleum gas (LPG) stove has more significant impact on indoor VOCs than the use of cooking stoves with natural gas as cooking fuel. (Author)

  4. A study on air pollution concentration at Desa parkcity construction site

    African Journals Online (AJOL)

    This study assesses the effect of construction workers exposure towards the air pollution to the correlation between meteorological factor with the particulate matter and other gases concentration at a construction site in DesaParkcity. The concentration of PM was collected by using low volume sampler meanwhile CO, CO2, ...

  5. Energy efficient piston configuration for effective air motion – A CFD study

    International Nuclear Information System (INIS)

    Gnana Sagaya Raj, Antony Raj; Mallikarjuna, Jawali Maharudrappa; Ganesan, Venkitachalam

    2013-01-01

    Highlights: ► All piston crown show similar flow pattern for experimental and simulated studies. ► Piston position plays a predominant role in the air pattern inside the cylinder. ► The flat bowl piston shows higher TKE compared to all other piston crown shape. ► The turbulence intensity and length scale are higher for flat bowl piston. ► The quantitative error between the CFD and PIV analysis is about 5%. -- Abstract: Air motion inside the cylinder is very important from the point of view of energy efficiency. In this direction, piston configuration plays a very crucial role. This study is concerned with the CFD analysis of in-cylinder air motion coupled with the comparison of predicted results with the experimental results available in the literature. Four configurations viz., flat, inclined, centre bowl and inclined offset bowl pistons have been studied. For numerical analysis STAR-CD CFD software has been used. Experimental results available in the literature for comparison are obtained by PIV measurements. From this study, it is concluded that a centre bowl on flat piston is found to be the best from the point of view of tumble ratio, turbulent kinetic energy, turbulent intensity and turbulent length scale which play very important role in imparting proper air motion, there by increasing the energy efficiency of the engine.

  6. Air travel and venous thrombosis. Results of the WRIGHT study. Part II : Mechanism

    NARCIS (Netherlands)

    Schreijer, Anja Johanna Maria

    2009-01-01

    Air travel has become a well-known risk factor for venous thrombosis with an absolute risk of 1 in 4600 long-haul flights and a dose-response relationship with duration and number of flights. In this thesis we studied the pathophysiology that underlies the risk as well as the effect of behaviour

  7. EC multicentre study on small area variations in air quality and health (SAVIAH)

    Energy Technology Data Exchange (ETDEWEB)

    Lebret, E [National Inst. of Public Health and Environmental Protection (Netherlands); Elliott, P [London School of Hygiene and Tropical Medicine (United Kingdom); Briggs, D [Huddersfield Univ. (United Kingdom). Inst. of Environmental and Policy Analysis; Gorynski, P [National Inst. of Hygiene, Warsaw (Poland); Kriz, B [National Inst. of Public Health, Prague (Czech Republic)

    1996-12-31

    SAVIAH is an EC-funded methodological study coordinated by Dr. Paul Elliott at the LSHTM (London School of Hygiene and Tropical Medicine). The project aims to apply, test and evaluate new and emerging methodologies in the fields of epidemiology, geography, air pollution modelling and small area health statistics, and to bring the data together in a consistent geographic framework. The study was carried out in the U.K., The Netherlands, Poland and the Czech Republic, using the example of childhood wheeze and outdoor air pollution. Specific aims of the study were, in each centre, (1) to carry out a questionnaire survey among parents of guardians of around 4000 to 5000 children aged between 7 and 11, (2) to carry out a series of air pollution surveys for NO{sub 2} as a proxy for the complex of traffic-related pollutants, and SO{sub 2} (PL), using a dense network of passive samplers, (3) to build up a detailed Geographical Information System (GIS) for each of the study areas; (4) to construct an air pollution `map` based on the NO{sub 2} and SO{sub 2} measurements and a health `map` based on `map smoothing` techniques and (5) to explore methods to examine relationships between health, pollution, socio-economic and other data. (author)

  8. Air pollution and forest health studies along a south-north transect in Poland

    Science.gov (United States)

    Stefan Godzik; Jerzy Szdzuj; Tomasz Staszewski; Wlodzimierz Lukasik

    1998-01-01

    Air pollution, bulk deposition and throughfall, soil characteristics, needle chemistry, and forest injury were studied on six permanent plots from the south (Brenna and Salmopol in the Beskidy Mountains) to the north (Gac, the Baltic Sea coastal area) in Poland. The concentrations of sulfur dioxide and nitrogen dioxide were the highest at the Katowice location and the...

  9. EC multicentre study on small area variations in air quality and health (SAVIAH)

    Energy Technology Data Exchange (ETDEWEB)

    Lebret, E. [National Inst. of Public Health and Environmental Protection (Netherlands); Elliott, P. [London School of Hygiene and Tropical Medicine (United Kingdom); Briggs, D. [Huddersfield Univ. (United Kingdom). Inst. of Environmental and Policy Analysis; Gorynski, P. [National Inst. of Hygiene, Warsaw (Poland); Kriz, B. [National Inst. of Public Health, Prague (Czech Republic)

    1995-12-31

    SAVIAH is an EC-funded methodological study coordinated by Dr. Paul Elliott at the LSHTM (London School of Hygiene and Tropical Medicine). The project aims to apply, test and evaluate new and emerging methodologies in the fields of epidemiology, geography, air pollution modelling and small area health statistics, and to bring the data together in a consistent geographic framework. The study was carried out in the U.K., The Netherlands, Poland and the Czech Republic, using the example of childhood wheeze and outdoor air pollution. Specific aims of the study were, in each centre, (1) to carry out a questionnaire survey among parents of guardians of around 4000 to 5000 children aged between 7 and 11, (2) to carry out a series of air pollution surveys for NO{sub 2} as a proxy for the complex of traffic-related pollutants, and SO{sub 2} (PL), using a dense network of passive samplers, (3) to build up a detailed Geographical Information System (GIS) for each of the study areas; (4) to construct an air pollution `map` based on the NO{sub 2} and SO{sub 2} measurements and a health `map` based on `map smoothing` techniques and (5) to explore methods to examine relationships between health, pollution, socio-economic and other data. (author)

  10. A Novice-Expert Study of Modeling Skills and Knowledge Structures about Air Quality

    Science.gov (United States)

    Hsu, Ying-Shao; Lin, Li-Fen; Wu, Hsin-Kai; Lee, Dai-Ying; Hwang, Fu-Kwun

    2012-01-01

    This study compared modeling skills and knowledge structures of four groups as seen in their understanding of air quality. The four groups were: experts (atmospheric scientists), intermediates (upper-level graduate students in a different field), advanced novices (talented 11th and 12th graders), and novices (10th graders). It was found that when…

  11. Self-directed learning skills in air-traffic control; A cued retrospective reporting study

    NARCIS (Netherlands)

    Van Meeuwen, Ludo; Brand-Gruwel, Saskia; Van Merriënboer, Jeroen; Kirschner, Paul A.; De Bock, Jeano

    2011-01-01

    Van Meeuwen, L. W., Brand-Gruwel, S., Van Merriënboer, J. J. G., Kirschner, P. A., & De Bock, J. J. P. R. (2010, May). Self-directed learning skills in air-traffic control; A cued retrospective reporting study. Presented at the Scandinavian Workshop on Applied Eye-tracking. Lund, Sweden.

  12. Expertise differences in air traffic control: An eye-tracking study

    NARCIS (Netherlands)

    Van Meeuwen, Ludo; Jarodzka, Halszka; Brand-Gruwel, Saskia; Kirschner, Paul A.; De Bock, Jeano; Van Merriënboer, Jeroen

    2012-01-01

    Van Meeuwen, L. W., Jarodzka, H., Brand-Gruwel, S., Kirschner, P. A., De Bock, J. J. P. R., & Van Merriënboer, J. J. G. (2012, April). Expertise differences in air traffic control: An eye-tracking study. Paper presented at the American Educational Research Association Annual Meeting 2012, Vancouver,

  13. Summarising climate and air quality (ozone) data on self-organising maps: a Sydney case study.

    Science.gov (United States)

    Jiang, Ningbo; Betts, Alan; Riley, Matt

    2016-02-01

    This paper explores the classification and visualisation utility of the self-organising map (SOM) method in the context of New South Wales (NSW), Australia, using gridded NCEP/NCAR geopotential height reanalysis for east Australia, together with multi-site meteorological and air quality data for Sydney from the NSW Office of Environment and Heritage Air Quality Monitoring Network. A twice-daily synoptic classification has been derived for east Australia for the period of 1958-2012. The classification has not only reproduced the typical synoptic patterns previously identified in the literature but also provided an opportunity to visualise the subtle, non-linear change in the eastward-migrating synoptic systems influencing NSW (including Sydney). The summarisation of long-term, multi-site air quality/meteorological data from the Sydney basin on the SOM plane has identified a set of typical air pollution/meteorological spatial patterns in the region. Importantly, the examination of these patterns in relation to synoptic weather types has provided important visual insights into how local and synoptic meteorological conditions interact with each other and affect the variability of air quality in tandem. The study illustrates that while synoptic circulation types are influential, the within-type variability in mesoscale flows plays a critical role in determining local ozone levels in Sydney. These results indicate that the SOM can be a useful tool for assessing the impact of weather and climatic conditions on air quality in the regional airshed. This study further promotes the use of the SOM method in environmental research.

  14. Study on the impact of air quality in agricultural and health sectors

    Science.gov (United States)

    Chairani, S.

    2018-03-01

    This study focused on the impact of air quality in agricultural and health sectors. The impact of CO2 on the agricultural crops was conducted by using literature review and the impact of air quality was conducted using secondary data to calculate the Air Quality Index (AQI), derived from some monitoring stations available in Indonesia. Numerous studies showed that the elevated CO2 decreased the agricultural productivity. Maize yields decreased by 15 % in areas which used irrigation system and 8 % in areas which used rainfed. Maize yields had already experienced severe losses without increasing CO2 concentrations. It decreased by 21 % for irrigated maize and 26 % by rainfed maize. In addition, it turned out that other elevated pollutants, such as SO2, NO2, SPM, O3, CH4, PM2.5, PM10 and TSP also occurred in the atmosphere. These pollutants’ effects might harm human being in term of health concern. The USEPA had developed a tool, called the Air Quality Index (AQI) calculator to calculate the pollutants’ concentrations in a daily basis. This tool’s function to inform how clean or polluted the air that we breathed was with the health effects based on the concentrations of each pollutant. The AQI also provided the information on sensitive groups, health effects and cautionary statements. Based on the air daily data which derived from Board of Meteorology, Climatology and Geophysics (BMKG) of Indonesia, the AQI in Indonesia varied from good, moderate to unhealthy categories; with level of health concern was respiratory diseases, such as asthma.

  15. Air pollution and emergency department visits for respiratory diseases: A multi-city case crossover study.

    Science.gov (United States)

    Szyszkowicz, Mieczysław; Kousha, Termeh; Castner, Jessica; Dales, Robert

    2018-05-01

    Increasing evidence suggests that ambient air pollution is a major risk factor for both acute and chronic respiratory disease exacerbations and emergencies. The objective of this study was to determine the association between ambient air pollutants and emergency department (ED) visits for respiratory conditions in nine districts across the province of Ontario in Canada. Health, air pollutant (PM 2.5 , NO 2 , O 3 , and SO 2 ), and meteorological data were retrieved from April 2004 to December 2011. Respiratory diseases were categorized as: chronic obstructive pulmonary disease (COPD, including bronchiectasis) and acute upper respiratory diseases. A case-crossover design was used to test the associations between ED visits and ambient air pollutants, stratified by sex and season. For COPD among males, positive results were observed for NO 2 with lags of 3-6 days, for PM 2.5 with lags 1-8, and for SO 2 with lags of 4-8 days. For COPD among females, positive results were observed for O 3 with lags 2-4 days, and for SO 2 among lags of 3-6 days. For upper respiratory disease emergencies among males, positive results were observed for NO 2 (lags 5-8 days), for O 3 , (lags 0-6 days), PM 2.5 (all lags), and SO 2 (lag 8), and among females, positive results were observed for NO 2 for lag 8 days, for O 3 , PM 2.5 among all lags. Our study provides evidence of the associations between short-term exposure to air pollution and increased risk of ED visits for upper and lower respiratory diseases in an environment where air pollutant concentrations are relatively low. Crown Copyright © 2018. Published by Elsevier Inc. All rights reserved.

  16. A study protocol to evaluate the relationship between outdoor air pollution and pregnancy outcomes

    Directory of Open Access Journals (Sweden)

    Selemane Ismael

    2010-10-01

    Full Text Available Abstract Background The present study protocol is designed to assess the relationship between outdoor air pollution and low birth weight and preterm births outcomes performing a semi-ecological analysis. Semi-ecological design studies are widely used to assess effects of air pollution in humans. In this type of analysis, health outcomes and covariates are measured in individuals and exposure assignments are usually based on air quality monitor stations. Therefore, estimating individual exposures are one of the major challenges when investigating these relationships with a semi-ecologic design. Methods/Design Semi-ecologic study consisting of a retrospective cohort study with ecologic assignment of exposure is applied. Health outcomes and covariates are collected at Primary Health Care Center. Data from pregnant registry, clinical record and specific questionnaire administered orally to the mothers of children born in period 2007-2010 in Portuguese Alentejo Litoral region, are collected by the research team. Outdoor air pollution data are collected with a lichen diversity biomonitoring program, and individual pregnancy exposures are assessed with spatial geostatistical simulation, which provides the basis for uncertainty analysis of individual exposures. Awareness of outdoor air pollution uncertainty will improve validity of individual exposures assignments for further statistical analysis with multivariate regression models. Discussion Exposure misclassification is an issue of concern in semi-ecological design. In this study, personal exposures are assigned to each pregnant using geocoded addresses data. A stochastic simulation method is applied to lichen diversity values index measured at biomonitoring survey locations, in order to assess spatial uncertainty of lichen diversity value index at each geocoded address. These methods assume a model for spatial autocorrelation of exposure and provide a distribution of exposures in each study location

  17. A study protocol to evaluate the relationship between outdoor air pollution and pregnancy outcomes.

    Science.gov (United States)

    Ribeiro, Manuel C; Pereira, Maria J; Soares, Amílcar; Branquinho, Cristina; Augusto, Sofia; Llop, Esteve; Fonseca, Susana; Nave, Joaquim G; Tavares, António B; Dias, Carlos M; Silva, Ana; Selemane, Ismael; de Toro, Joaquin; Santos, Mário J; Santos, Fernanda

    2010-10-15

    The present study protocol is designed to assess the relationship between outdoor air pollution and low birth weight and preterm births outcomes performing a semi-ecological analysis. Semi-ecological design studies are widely used to assess effects of air pollution in humans. In this type of analysis, health outcomes and covariates are measured in individuals and exposure assignments are usually based on air quality monitor stations. Therefore, estimating individual exposures are one of the major challenges when investigating these relationships with a semi-ecologic design. Semi-ecologic study consisting of a retrospective cohort study with ecologic assignment of exposure is applied. Health outcomes and covariates are collected at Primary Health Care Center. Data from pregnant registry, clinical record and specific questionnaire administered orally to the mothers of children born in period 2007-2010 in Portuguese Alentejo Litoral region, are collected by the research team. Outdoor air pollution data are collected with a lichen diversity biomonitoring program, and individual pregnancy exposures are assessed with spatial geostatistical simulation, which provides the basis for uncertainty analysis of individual exposures. Awareness of outdoor air pollution uncertainty will improve validity of individual exposures assignments for further statistical analysis with multivariate regression models. Exposure misclassification is an issue of concern in semi-ecological design. In this study, personal exposures are assigned to each pregnant using geocoded addresses data. A stochastic simulation method is applied to lichen diversity values index measured at biomonitoring survey locations, in order to assess spatial uncertainty of lichen diversity value index at each geocoded address. These methods assume a model for spatial autocorrelation of exposure and provide a distribution of exposures in each study location. We believe that variability of simulated exposure values at

  18. Pure rotational CARS thermometry studies of low-temperature oxidation kinetics in air and ethene-air nanosecond pulse discharge plasmas

    International Nuclear Information System (INIS)

    Zuzeek, Yvette; Choi, Inchul; Uddi, Mruthunjaya; Adamovich, Igor V; Lempert, Walter R

    2010-01-01

    Pure rotational CARS thermometry is used to study low-temperature plasma assisted fuel oxidation kinetics in a repetitive nanosecond pulse discharge in ethene-air at stoichiometric and fuel lean conditions at 40 Torr pressure. Air and fuel-air mixtures are excited by a burst of high-voltage nanosecond pulses (peak voltage, 20 kV; pulse duration, ∼ 25 ns) at a 40 kHz pulse repetition rate and a burst repetition rate of 10 Hz. The number of pulses in the burst is varied from a few pulses to a few hundred pulses. The results are compared with the previously developed hydrocarbon-air plasma chemistry model, modified to incorporate non-empirical scaling of the nanosecond discharge pulse energy coupled to the plasma with number density, as well as one-dimensional conduction heat transfer. Experimental time-resolved temperature, determined as a function of the number of pulses in the burst, is found to agree well with the model predictions. The results demonstrate that the heating rate in fuel-air plasmas is much faster compared with air plasmas, primarily due to energy release in exothermic reactions of fuel with O atoms generated by the plasma. It is found that the initial heating rate in fuel-air plasmas is controlled by the rate of radical (primarily O atoms) generation and is nearly independent of the equivalence ratio. At long burst durations, the heating rate in lean fuel air-mixtures is significantly reduced when all fuel is oxidized.

  19. Baseline Studies of Selected Polybrominated Diphenyl Ethers in the Air of the Nandamojo Watershed, Costa Rica

    Science.gov (United States)

    Geesey, Mary Sophia

    Polybrominated diphenyl ethers (PBDEs) have been used as flame retardants in a number of common household and commercial products around the world. PBDEs enter the environment in a variety of ways, such as through emissions, leaching from end-of-life electronics in landfills, and incineration. While many countries have phased out the manufacturing of penta-, octa-, and deca-PBDEs or have banned the manufacture and use of these congeners altogether, these persistent organic pollutants (POPs) continue to be detected in humans and the environment. This study investigates spatial and temporal variations of selected PBDEs in the air of the Nandamojo watershed area in Costa Rica by comparing air concentrations of PBDEs in the dry winter vs. wet summer seasons and rural vs. urban areas and also investigates the impact of anthropogenic activities on air concentration of PBDEs. This study is significant to the field, because there are no baseline studies nor are there currently any monitoring programs to assess the environmental levels of PBDEs or other POPs for this region of the Guanacaste province. Baseline information is needed to track spatial and temporal trends as well as evaluate the effectiveness of control measures employed nationally and internationally. Samples obtained from passive air sampling devices were analyzed via GC/MS for a number of congeners. PBDE-47 and -99 were found to be the congeners present in greatest concentration in air samples from the Nandamojo watershed area. Air concentrations were estimated assuming an average sampler uptake rate of 3.5 m3/day and ranged as follows: SigmaPBDE5 35.20-1549.25 pg/m3 over the entire study. The presence of PBDEs in remote and pristine environments indicates that PBDEs are now a global concern. This study suggests that the spatial and temporal distribution patterns observed are strongly related to anthropogenic activities and presence of a population similar to that observed in other studies. The presence of

  20. Individual traffic-related air pollution and new onset adult asthma:A GIS-based pilot study

    DEFF Research Database (Denmark)

    Lysbeck Hansen, Carl; Jensen, Steen Solvang; Baelum, Jesper

    The background for the project is that traffic-related air pollution may provoke the onset of asthma. The objective of this pilot study is to investigate the relation between asthma and wheeze debut and individually estimated exposure to traffic-related air pollutants with a validated exposure...... system (AirGIS). The project applied the following methodology. A non-smoking cohort with recently acquired asthma or wheeze as well as matched controls were identified from a large cross-sectional study. All residential and working addresses with corresponding time periods for a 10 year period were...... successfully identified for all study participants (N=33). Using AirGIS traffic-related air pollutant levels from both urban background and street level were estimated for the 10 year study period on an hourly basis. Individual levels of air pollutants in the years preceding debut of asthma or wheeze were...

  1. A study on a relationship between prevalence of respiratory disease and air pollution in two areas

    OpenAIRE

    五島,正規

    2000-01-01

    There have been many studies on the relationship between prevalence and incidence of respiratory disease and air pollution. This study was conducted by organized efforts of a regional medical association. Every member of the association reported the numbers of patients with respiratory diseases such as asthmatic bronchitis, chronic bronchitis, and bronchial asthma, and the total number of patients who consulted him/her. The former report was conducted in K city, and this study was of the Y ar...

  2. Mapping Social Vulnerability to Air Pollution: A Case Study of the Yangtze River Delta Region, China

    Directory of Open Access Journals (Sweden)

    Yi Ge

    2017-01-01

    Full Text Available Many frequent and severe air pollution incidents have emerged across the vast parts of China recently. The identification of factors and mapping social vulnerability has become extremely necessary for environmental management and sustainable development. However, studies associating social vulnerability with air pollution remain sparse. With reference to research achievements of social vulnerability, this study made a new trial regarding social vulnerability assessment to air pollution. With the projection pursuit cluster (PPC model, the top three factors contributing to social vulnerability index (SVI were discovered and SVI and SVI dimensions (susceptibility, exposure, and adaptability were evaluated. Results revealed that adaptability values are higher than susceptibility and exposure values. SVI is in a poor condition as, for the whole region, most values belong to the high-medium level. High SVI values mainly appear in the northern and the southern ends of study area. SVI in Shanghai is lower than in Jiangsu and Zhejiang provinces. On the scale of prefecture-level city, it can be found that the low-value centers of SVI always occurred in urban core areas. The spatial variation and inequality in social vulnerability provide policy-makers a scientific basis for air pollution prevention and sustainable management.

  3. High-resolution real-time optical studies of radiological air sample filtration processes in an environmental continuous air monitor

    Science.gov (United States)

    Rodgers, John C.; Wasiolek, Piotr T.; Schery, Stephen D.; Alcantara, Raul E.

    1999-01-01

    The need for a continuous air monitor capable of quick and accurate measurements of airborne radioactivity in close proximity to the work environment during waste management, site restoration, and D&D operations led to the Los Alamos National Laboratory development of an environmental continuous air monitor (ECAM). Monitoring the hostile work environment of waste recovery, for example, presents unique challenges for detector design for detectors previously used for the clean room conditions of the typical plutonium laboratory. The environmental and atmospheric conditions (dust, high wind, etc.) influence aerosol particle penetration into the ECAM sampling head as well as the build-up of deposits on the ECAM filter.

  4. Novel device (AirWave) to assess endotracheal tube migration: a pilot study.

    Science.gov (United States)

    Nacheli, Gustavo Cumbo; Sharma, Manish; Wang, Xiaofeng; Gupta, Amit; Guzman, Jorge A; Tonelli, Adriano R

    2013-08-01

    Little is known about endotracheal tube (ETT) migration during routine care among critically ill patients. AirWave is a novel device that uses sonar waves to measure ETT migration and obstructions in real time. The aim of the present study is to assess the accuracy of the AirWave to evaluate ETT migration. In addition, we determined the degree of variation in ETT position and tested whether more pronounced migration occurs in specific clinical scenarios. After institutional review board approval, we included mechanically ventilated patients from February 2012 to May 2012. A chest radiography (CXR) was obtained at baseline and 24 hours when clinically indicated. The ETT distance at the lips was recorded at baseline and every 4 hours. The AirWave system continuously recorded ETT position changes from baseline, and luminal obstructions. A total of 42 patients (age: 61 [SD ±13] years, men: 52%) were recruited. A total of 19 patients had measurements of ETT migration at 24 hours by the 3 methodologies used in this study. The mean (SD) of the ETT migration at 24 hours was +0.04 (1.2), -0.42 (0.7) and +0.34 (1.81) cm when measured by portable CXR, ETT distance at the teeth and AirWave device, respectively. Bland-Altman analysis of tube migration at 24 hours comparing the AirWave with CXR readings showed a bias of 0.1 cm with 95% limit of agreement of -3.8 and +4.3 cm. Comparison of tube migration at 24 hours determined by AirWave with ETT distance at the lips revealed a bias of -0.4 with 95% limit of agreement -3.7 to +3 cm, similar to the values observed between CXR and ETT distance at the lips (bias of -0.3 cm, 95% limit of agreement of -3.4 to +2.8 cm). Factors associated with ETT migration at 24 hours were ETT size and initial measurement from ETT tip to carina by portable CXR. AirWave detected in eight patients some degree of ETT obstruction (30% ± 9.6%) that resolved with prompt ETT catheter suction. The AirWave may provide useful information regarding ETT

  5. Air pollution biomonitoring in Argentina, application of neutron activation analysis to the study of biomonitors

    International Nuclear Information System (INIS)

    Pignata, Maria Luisa; Pla, Rita R.

    2001-01-01

    Due to low population density, total air pollutant emissions in Argentina are still low if compared with highly industrialised countries. Although a significant deterioration of air quality has been observed for a long time, air monitoring did not begin until the 90's and only in a few cities. The use of air pollution biomonitors represents an important contribution to Argentina, as measurements of air pollutants in large areas would require especial technical equipment not easily available and operated. In this project, two lichen species (Ramalina ecklonii (Spreng) Mey and Flot and Usnea amblyoclada (Muell. Rg.) Zahlbr.) and a Bromeliaceae (Tillandsia capillaris) are used as biomonitors of air pollution at a 50, 000 km 2 area in Cordoba province (central Argentina). AAS and INAA have been applied for the analysis of samples, determining As, Ba, Br, Ce, Co, Cr, Cs, Cu, Eu, Fe, Hf, Gd, K, La, Lu, Mn, Na, Ni, Pb, Rb, Sb, Sc, Sm, Ta, Tb, Th, U, Yb and Zn. The following physiological parameters were also determined: chlorophyll a, chloropyll b, phaeophytin a, phaeophytin b, hydroperoxy conjugated dienes, malonaldehide and sulphur. Some of these parameters were used for calculating a pollution index. These determinations were carried out on pools collected at the sampling sites. AAS and physiological parameters were also applied to the analysis of five-replicate samples in order to study variability sources. For data evaluation, different statistical and other evaluating tools were used: descriptive statistics and Spearman's correlation analysis were used on data from the three biomonitor species while factor analysis and mapping, only for R. ecklonii results. (author)

  6. Chemical characterization of particulate air pollutants Case studies on indoor air quality, cultural heritage and the marine environment

    Science.gov (United States)

    Horemans, Benjamin

    When attempting to discuss the effects of airborne particulate matter (PM), it is important to address both physical and chemical aspects of this pollutant. This work reports on the results of three separate case studies, each approaching a specific problem of air pollution by evaluating the chemical composition of PM. 1. In the US and Europe, office workers often complain about work-related health symptoms. These symptoms are collectively referred as the 'sick building syndrome'. This work could be considered as one of the largest data collections on particulate pollutants in Belgian offices. It helps to understand the sources as well as the behavior and fate of PM at our workplace environments. Especially the chemical information on PM makes the results unique, since it enables a better evaluation of the health risks connected to office dust. 2. The Alhambra and Generalife bring every year more than 3 million people to Granada in Southern Spain. Recently, the increasing urbanization of Granada and the immense pressure of mass tourism form a threat for this heritage. Despite the fact that atmospheric pollutants are known to he potentially aggressive for our cultural patrimony. this case study is the first to assess the effects of environmental aerosols on the Alhambra monument. The results of this study could help decision-makers at the Alhambra and the city of Granada with the formulation of preventive conservation measures. They show how local vehicular traffic is the main source for atmospheric pollution in and around the Alhambra monument. Targeted strategies are necessary in order to maximally preserve these monuments and their UNESCO world cultural heritage label. 3. Excessive input of nitrogen-containing atmospheric nutrients via dry and wet deposition can cause entrophication of marine regions, which is also a common, seasonal phenomenon along the coasts of the North Sea. This study is the first to give a complete quantitative description of the

  7. SEM study of the effects of crude oil on the gills and air breathing organs of climbing perch, Anabas testudineus

    International Nuclear Information System (INIS)

    Prasad, M.S.

    1991-01-01

    Ultrastructural studies on the effects of crude oil on the gills are scanty. Recently, researchers studied the effect of crude oil on the air breathing organs of striped gourami using scanning electron microscope and observed mucous cell hyperplasia coupled with telangiectasis in the epithelia of air breathing organs. The present investigation has been undertaken to study crude oil toxicity by observing the morphological changes occurring in the epithelia of gills and air breathing organs of climbing perch, Anabas testudineus at SEM level. Since the epithelia of gills and air breathing organs function in two different media, a comparative account for their sensitivity to crude oil solutions would be informative

  8. Experimental study of film media used for evaporative pre-cooling of air

    International Nuclear Information System (INIS)

    He, Suoying; Guan, Zhiqiang; Gurgenci, Hal; Hooman, Kamel; Lu, Yuanshen; Alkhedhair, Abdullah M.

    2014-01-01

    Highlights: • Two film media were experimentally studied in a low-speed wind tunnel. • Correlations for heat transfer coefficient and pressure drop were developed. • Cellulose media provide higher cooling efficiency and pressure drop than PVC media. • Water entrainment of PVC media happens even at relatively low air velocities. - Abstract: An open-circuit low-speed wind tunnel was used to study the performance of evaporative cooling with cellulose and Polyvinyl Chloride (PVC) corrugated media. These two film media were selected as part of a broader investigation on pre-cooling the entering air of natural draft dry cooling towers. The heat and mass transfer and pressure drop across the two media with three thicknesses (i.e., 100, 200 and 300 mm) were experimentally studied in the wind tunnel. The test data were non-dimensionalized and curve fitted to yield a set of correlations. It was found that the pressure drop range of the cellulose media is 1.5–101.7 Pa while the pressure drops of the PVC media are much lower with the range of 0.9–49.2 Pa, depending on the medium thickness, air velocity and water flow rate. The cooling efficiencies of the cellulose media vary from 43% to 90% while the cooling efficiencies of the PVC media are 8% to 65%, depending on the medium thickness and air velocity. The water entrainment off the media was detected by water sensitive papers, and found that the cellulose media have negligible water entrainment under the studied conditions while care must be taken in the use of PVC media as water entrainment happens even at relatively low air velocities

  9. Experimental feasibility study of radial injection cooling of three-pad radial air foil bearings

    Science.gov (United States)

    Shrestha, Suman K.

    Air foil bearings use ambient air as a lubricant allowing environment-friendly operation. When they are designed, installed, and operated properly, air foil bearings are very cost effective and reliable solution to oil-free turbomachinery. Because air is used as a lubricant, there are no mechanical contacts between the rotor and bearings and when the rotor is lifted off the bearing, near frictionless quiet operation is possible. However, due to the high speed operation, thermal management is one of the very important design factors to consider. Most widely accepted practice of the cooling method is axial cooling, which uses cooling air passing through heat exchange channels formed underneath the bearing pad. Advantage is no hardware modification to implement the axial cooling because elastic foundation structure of foil bearing serves as a heat exchange channels. Disadvantage is axial temperature gradient on the journal shaft and bearing. This work presents the experimental feasibility study of alternative cooling method using radial injection of cooling air directly on the rotor shaft. The injection speeds, number of nozzles, location of nozzles, total air flow rate are important factors determining the effectiveness of the radial injection cooling method. Effectiveness of the radial injection cooling was compared with traditional axial cooling method. A previously constructed test rig was modified to accommodate a new motor with higher torque and radial injection cooling. The radial injection cooling utilizes the direct air injection to the inlet region of air film from three locations at 120° from one another with each location having three axially separated holes. In axial cooling, a certain axial pressure gradient is applied across the bearing to induce axial cooling air through bump foil channels. For the comparison of the two methods, the same amount of cooling air flow rate was used for both axial cooling and radial injection. Cooling air flow rate was

  10. Exploring the concept of compressed air energy storage (CAES) in lined rock caverns at shallow depth: A modeling study of air tightness and energy balance

    Energy Technology Data Exchange (ETDEWEB)

    Kim, H.-M.; Rutqvist, J.; Ryu, D.-W.; Choi, B.-H.; Sunwoo, C.; Song, W.-K.

    2011-07-15

    This paper presents a numerical modeling study of coupled thermodynamic, multiphase fluid flow and heat transport associated with underground compressed air energy storage (CAES) in lined rock caverns. Specifically, we explored the concept of using concrete lined caverns at a relatively shallow depth for which constructing and operational costs may be reduced if air tightness and stability can be assured. Our analysis showed that the key parameter to assure long-term air tightness in such a system was the permeability of both the concrete lining and the surrounding rock. The analysis also indicated that a concrete lining with a permeability of less than 1×10{sup -18} m{sup 2} would result in an acceptable air leakage rate of less than 1%, with the operational pressure range between 5 and 8 MPa at a depth of 100 m. It was further noted that capillary retention properties and the initial liquid saturation of the lining were very important. Indeed, air leakage could be effectively prevented when the air-entry pressure of the concrete lining is higher than the operational air pressure and when the lining is kept moist at a relatively high liquid saturation. Our subsequent energy-balance analysis demonstrated that the energy loss for a daily compression and decompression cycle is governed by the air-pressure loss, as well as heat loss by conduction to the concrete liner and surrounding rock. For a sufficiently tight system, i.e., for a concrete permeability off less than 1×10{sup -18} m{sup 2}, heat loss by heat conduction tends to become proportionally more important. However, the energy loss by heat conduction can be minimized by keeping the air-injection temperature of compressed air closer to the ambient temperature of the underground storage cavern. In such a case, almost all the heat loss during compression is gained back during subsequent decompression. Finally, our numerical simulation study showed that CAES in shallow rock caverns is feasible from a leakage

  11. Design of an Air Pollution Monitoring Campaign in Beijing for Application to Cohort Health Studies.

    Science.gov (United States)

    Vedal, Sverre; Han, Bin; Xu, Jia; Szpiro, Adam; Bai, Zhipeng

    2017-12-15

    No cohort studies in China on the health effects of long-term air pollution exposure have employed exposure estimates at the fine spatial scales desirable for cohort studies with individual-level health outcome data. Here we assess an array of modern air pollution exposure estimation approaches for assigning within-city exposure estimates in Beijing for individual pollutants and pollutant sources to individual members of a cohort. Issues considered in selecting specific monitoring data or new monitoring campaigns include: needed spatial resolution, exposure measurement error and its impact on health effect estimates, spatial alignment and compatibility with the cohort, and feasibility and expense. Sources of existing data largely include administrative monitoring data, predictions from air dispersion or chemical transport models and remote sensing (specifically satellite) data. New air monitoring campaigns include additional fixed site monitoring, snapshot monitoring, passive badge or micro-sensor saturation monitoring and mobile monitoring, as well as combinations of these. Each of these has relative advantages and disadvantages. It is concluded that a campaign in Beijing that at least includes a mobile monitoring component, when coupled with currently available spatio-temporal modeling methods, should be strongly considered. Such a campaign is economical and capable of providing the desired fine-scale spatial resolution for pollutants and sources.

  12. A pilot study of indoor air quality in screen golf courses.

    Science.gov (United States)

    Goung, Sun-Ju Nam; Yang, Jinho; Kim, Yoon Shin; Lee, Cheol Min

    2015-05-01

    The aims of this study were to provide basic data for determining policies on air quality for multi-user facilities, including the legal enrollment of the indoor air quality regulation as designated by the Ministry of Environment, and to establish control plans. To this end, concentrations of ten pollutants (PM10, carbon monoxide (CO), carbon dioxide (CO2), nitrogen dioxide (NO2), formaldehyde (HCHO), total volatile organic compounds (TVOCs), radon (Rn), oxone (O3), total bacteria counts (TBC), and asbestos) in addition to nicotine, a smoking index material used to determine the impact of smoking on the air quality, were investigated in indoor game rooms and lobbies of 64 screen golf courses. The average concentration of none of the ten pollutants in the game rooms and lobbies of screen golf courses was found to exceed the limit set by the law. There were, however, pollutant concentrations exceeding limits in some screen golf courses, in order to establish a control plan for the indoor air quality of screen golf courses, a study on the emission sources of each pollutant was conducted. The major emission sources were found to be facility users' activities such as smoking and the use of combustion appliances, building materials, and finishing materials.

  13. Design of an Air Pollution Monitoring Campaign in Beijing for Application to Cohort Health Studies

    Directory of Open Access Journals (Sweden)

    Sverre Vedal

    2017-12-01

    Full Text Available No cohort studies in China on the health effects of long-term air pollution exposure have employed exposure estimates at the fine spatial scales desirable for cohort studies with individual-level health outcome data. Here we assess an array of modern air pollution exposure estimation approaches for assigning within-city exposure estimates in Beijing for individual pollutants and pollutant sources to individual members of a cohort. Issues considered in selecting specific monitoring data or new monitoring campaigns include: needed spatial resolution, exposure measurement error and its impact on health effect estimates, spatial alignment and compatibility with the cohort, and feasibility and expense. Sources of existing data largely include administrative monitoring data, predictions from air dispersion or chemical transport models and remote sensing (specifically satellite data. New air monitoring campaigns include additional fixed site monitoring, snapshot monitoring, passive badge or micro-sensor saturation monitoring and mobile monitoring, as well as combinations of these. Each of these has relative advantages and disadvantages. It is concluded that a campaign in Beijing that at least includes a mobile monitoring component, when coupled with currently available spatio-temporal modeling methods, should be strongly considered. Such a campaign is economical and capable of providing the desired fine-scale spatial resolution for pollutants and sources.

  14. Managing future air quality in megacities: A case study for Delhi

    Science.gov (United States)

    Amann, Markus; Purohit, Pallav; Bhanarkar, Anil D.; Bertok, Imrich; Borken-Kleefeld, Jens; Cofala, Janusz; Heyes, Chris; Kiesewetter, Gregor; Klimont, Zbigniew; Liu, Jun; Majumdar, Dipanjali; Nguyen, Binh; Rafaj, Peter; Rao, Padma S.; Sander, Robert; Schöpp, Wolfgang; Srivastava, Anjali; Vardhan, B. Harsh

    2017-07-01

    Megacities in Asia rank high in air pollution at the global scale. In many cities, ambient concentrations of fine particulate matter (PM2.5) have been exceeding both the WHO interim targets as well as respective national air quality standards. This paper presents a systems analytical perspective on management options that could efficiently improve air quality at the urban scale, having Delhi as a case study. We employ the newly developed GAINS-City policy analysis framework, consisting of a bottom up emission calculation combined with atmospheric chemistry-transport calculation, to derive innovative insights into the current sources of pollution and their impacts on ambient PM2.5, both from emissions of primary PM as well as precursors of secondary inorganic and organic aerosols. We outline the likely future development of these sources, quantify the related ambient PM2.5 concentrations and health impacts, and explore potential policy interventions that could effectively reduce environmental pollution and resulting health impacts in the coming years. The analysis demonstrates that effective improvement of Delhi's air quality requires collaboration with neighboring States and must involve sources that are less relevant in industrialized countries. At the same time, many of the policy interventions will have multiple co-benefits on development targets in Delhi and its neighboring States. Outcomes of this study, as well as the modelling tools used herein, are applicable to other urban areas and fast growing metropolitan zones in the emerging Asian regions.

  15. Hybrid Air Quality Modeling Approach for use in the Hear-road Exposures to Urban air pollutant Study(NEXUS)

    Science.gov (United States)

    The paper presents a hybrid air quality modeling approach and its application in NEXUS in order to provide spatial and temporally varying exposure estimates and identification of the mobile source contribution to the total pollutant exposure. Model-based exposure metrics, associa...

  16. Contributions of Open Air Museums in preserving heritage buildings: study of open-air museums in South East England

    Directory of Open Access Journals (Sweden)

    Zuraini Md Ali

    2010-12-01

    Full Text Available Most open air museums were established to preserve and present a threatened aspect of regional or national culture and to help forge a sense of identity and achievement. Britain's open air museums have aroused controversy among both museum professionals and building conservationists. They have been praised for spearheading innovative and vivacious approaches towards heritage interpretation and saving neglected buildings, while some have criticised them for inconsistent standards of conservation especially for taking buildings out of their original settings. Such architectural issues were strongly debated in the 1970s, while recent debates focus on popular approaches towards attracting the public to the past. This paper describes the evolution of open air museums in Britain, their contribution in conserving unloved buildings and how they have become an increasingly competitive tourist attraction. Observations and lessons learned from interviews and visit to two open air museums in South East England provides some insight about the importance of such museums. Operated as registered charity organisations, they have played significant roles not only in saving various buildings and structures from demolition but also in helping visitors to appreciate the rich heritage of these regions.

  17. [Global air monitoring study: a multi-country comparison of levels of indoor air pollution in different workplaces results from Tunisia].

    Science.gov (United States)

    Higbee, Cheryl; Travers, Mark; Hyland, Andrew; Cummings, K Michael; Dresler, Carolyn

    2007-09-01

    In 1986, a report of the U.S. Surgeon General concluded that second hand smoke is a cause of disease in healthy non smokers. Subsequent many nations including Tunisia implement smoke-free worksite regulations. The aim of our study is to test air quality in indoor ambient air venues in Tunisia. A TSI SidePak AM510 Personal Aerosol Monitor was used to sample, record the levels of respirable suspended particles (RSP) in the air and to assess the real-time concentration of particles less than 2.5 microm in micrograms per cubic meter, or PM2.5. Thirty three venues were sampled in Tunis. The venues were selected to get a broad range of size, location and type of venue. Venues included restaurants and cafés, bars, bus stations, hospitals, offices, and universities. The mean level of indoor air pollution was 296 microg/m3 ranged from 11 microg/m3 to 1,499 microg/m3. The level of indoor air pollution was 85% lower in venues that were smoke-free compared to venues where smoking was observed (ppollution were found in hospitals, offices and universities (52 microg/m3) and the highest level was found in a bar (1,499 micro/m3). Hospitality venues allowing indoor air smoking in Tunisia are significantly more polluted than both indoor smoke-free sites and outdoor air in Tunisia. This study demonstrates that workers and patrons are exposed to harmful levels of a known carcinogen and toxin. Policies that prohibit smoking in public worksites dramatically reduce second hand smoke exposure and improve worker and patron health.

  18. Air filtration and indoor air quality

    DEFF Research Database (Denmark)

    Bekö, Gabriel

    2006-01-01

    Demands for better indoor air quality are increasing, since we spend most of our time indoors and we are more and more aware of indoor air pollution. Field studies in different parts of the world have documented that high percentage of occupants in many offices and buildings find the indoor air...... decent ventilation and air cleaning/air filtration, high indoor air quality cannot be accomplished. The need for effective air filtration has increased with increasing evidence on the hazardous effects of fine particles. Moreover, the air contains gaseous pollutants, removal of which requires various air...... cleaning techniques. Supply air filter is one of the key components in the ventilation system. Studies have shown that used ventilation filters themselves can be a significant source of indoor air pollution with consequent impact on perceived air quality, sick building syndrome symptoms and performance...

  19. [Time series studies of air pollution by fires and the effects on human health].

    Science.gov (United States)

    do Carmo, Cleber Nascimento; Hacon, Sandra de Souza

    2013-11-01

    Burnoffs (intentional fires for agricultural purposes) and forest fires of large proportions have been observed in various regions of the planet. Exposure to high levels of air pollutants emitted by fires can be responsible for various harmful effects on human health. In this article, the literature on estimating acute effects of air pollution on human health by fires in the regions with the highest number of fires on the planet, using a time series approach is summarized. An attempt was made to identify gaps in knowledge. The study consisted of a narrative review, in which the characteristics of the selected studies were grouped by regions of the planet with a higher incidence of burnoffs: Amazon, America, Australia and Asia. The results revealed a large number of studies in Australia, few studies in the Amazon and great heterogeneity in the results on the significant effects on human health.

  20. PubMed search filters for the study of putative outdoor air pollution determinants of disease

    Science.gov (United States)

    Curti, Stefania; Gori, Davide; Di Gregori, Valentina; Farioli, Andrea; Baldasseroni, Alberto; Fantini, Maria Pia; Christiani, David C; Violante, Francesco S; Mattioli, Stefano

    2016-01-01

    Objectives Several PubMed search filters have been developed in contexts other than environmental. We aimed at identifying efficient PubMed search filters for the study of environmental determinants of diseases related to outdoor air pollution. Methods We compiled a list of Medical Subject Headings (MeSH) and non-MeSH terms seeming pertinent to outdoor air pollutants exposure as determinants of diseases in the general population. We estimated proportions of potentially pertinent articles to formulate two filters (one ‘more specific’, one ‘more sensitive’). Their overall performance was evaluated as compared with our gold standard derived from systematic reviews on diseases potentially related to outdoor air pollution. We tested these filters in the study of three diseases potentially associated with outdoor air pollution and calculated the number of needed to read (NNR) abstracts to identify one potentially pertinent article in the context of these diseases. Last searches were run in January 2016. Results The ‘more specific’ filter was based on the combination of terms that yielded a threshold of potentially pertinent articles ≥40%. The ‘more sensitive’ filter was based on the combination of all search terms under study. When compared with the gold standard, the ‘more specific’ filter reported the highest specificity (67.4%; with a sensitivity of 82.5%), while the ‘more sensitive’ one reported the highest sensitivity (98.5%; with a specificity of 47.9%). The NNR to find one potentially pertinent article was 1.9 for the ‘more specific’ filter and 3.3 for the ‘more sensitive’ one. Conclusions The proposed search filters could help healthcare professionals investigate environmental determinants of medical conditions that could be potentially related to outdoor air pollution. PMID:28003291

  1. PubMed search filters for the study of putative outdoor air pollution determinants of disease.

    Science.gov (United States)

    Curti, Stefania; Gori, Davide; Di Gregori, Valentina; Farioli, Andrea; Baldasseroni, Alberto; Fantini, Maria Pia; Christiani, David C; Violante, Francesco S; Mattioli, Stefano

    2016-12-21

    Several PubMed search filters have been developed in contexts other than environmental. We aimed at identifying efficient PubMed search filters for the study of environmental determinants of diseases related to outdoor air pollution. We compiled a list of Medical Subject Headings (MeSH) and non-MeSH terms seeming pertinent to outdoor air pollutants exposure as determinants of diseases in the general population. We estimated proportions of potentially pertinent articles to formulate two filters (one 'more specific', one 'more sensitive'). Their overall performance was evaluated as compared with our gold standard derived from systematic reviews on diseases potentially related to outdoor air pollution. We tested these filters in the study of three diseases potentially associated with outdoor air pollution and calculated the number of needed to read (NNR) abstracts to identify one potentially pertinent article in the context of these diseases. Last searches were run in January 2016. The 'more specific' filter was based on the combination of terms that yielded a threshold of potentially pertinent articles ≥40%. The 'more sensitive' filter was based on the combination of all search terms under study. When compared with the gold standard, the 'more specific' filter reported the highest specificity (67.4%; with a sensitivity of 82.5%), while the 'more sensitive' one reported the highest sensitivity (98.5%; with a specificity of 47.9%). The NNR to find one potentially pertinent article was 1.9 for the 'more specific' filter and 3.3 for the 'more sensitive' one. The proposed search filters could help healthcare professionals investigate environmental determinants of medical conditions that could be potentially related to outdoor air pollution. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  2. Adsorption of naphthalene and ozone on atmospheric air/ice interfaces coated with surfactants: a molecular simulation study.

    Science.gov (United States)

    Liyana-Arachchi, Thilanga P; Valsaraj, Kalliat T; Hung, Francisco R

    2012-03-15

    The adsorption of gas-phase naphthalene and ozone molecules onto air/ice interfaces coated with different surfactant species (1-octanol, 1-hexadecanol, or 1-octanal) was investigated using classical molecular dynamics (MD) simulations. Naphthalene and ozone exhibit a strong preference to be adsorbed at the surfactant-coated air/ice interfaces, as opposed to either being dissolved into the bulk of the quasi-liquid layer (QLL) or being incorporated into the ice crystals. The QLL becomes thinner when the air/ice interface is coated with surfactant molecules. The adsorption of both naphthalene and ozone onto surfactant-coated air/ice interfaces is enhanced when compared to bare air/ice interface. Both naphthalene and ozone tend to stay dissolved in the surfactant layer and close to the QLL, rather than adsorbing on top of the surfactant molecules and close to the air region of our systems. Surfactants prefer to orient at a tilted angle with respect to the air/ice interface; the angular distribution and the most preferred angle vary depending on the hydrophilic end group, the length of the hydrophobic tail, and the surfactant concentration at the air/ice interface. Naphthalene prefers to have a flat orientation on the surfactant coated air/ice interface, except at high concentrations of 1-hexadecanol at the air/ice interface; the angular distribution of naphthalene depends on the specific surfactant and its concentration at the air/ice interface. The dynamics of naphthalene molecules at the surfactant-coated air/ice interface slow down as compared to those observed at bare air/ice interfaces. The presence of surfactants does not seem to affect the self-association of naphthalene molecules at the air/ice interface, at least for the specific surfactants and the range of concentrations considered in this study.

  3. Controlling for unmeasured confounding and spatial misalignment in long?term air pollution and health studies

    OpenAIRE

    Lee, Duncan; Sarran, Christophe

    2015-01-01

    The health impact of long?term exposure to air pollution is now routinely estimated using spatial ecological studies, owing to the recent widespread availability of spatial referenced pollution and disease data. However, this areal unit study design presents a number of statistical challenges, which if ignored have the potential to bias the estimated pollution?health relationship. One such challenge is how to control for the spatial autocorrelation present in the data after accounting for the...

  4. Towards an air pollution health study data management system - A case study from a smoky Swiss railway

    NARCIS (Netherlands)

    Papoutsoglou, Evangelia; Samourkasidis, Argyrios; Tsai, Ming-Yi; Davey, Mark; Ineichen, Alex; Athanasiadis, Ioannis N.

    2015-01-01

    In air pollution health studies, measurements are conducted intensively but only periodically at numerous locations in a variety of environments (indoors, outdoors, personal). Often a variety of instruments are used to measure various pollutants ranging from gases (eg, CO, NO2, O3, VOCs, PAHs) to

  5. Public Perception of Urban Air Pollution: An Exploratory Study; Percepcion Publica de la Contaminacion Atmosferica Urbana: Un Analisis Exploratorio

    Energy Technology Data Exchange (ETDEWEB)

    Sola, R.; Oltra, C.; Goncalves, L.

    2014-02-01

    This report presents the results of a qualitative study using focus groups aimed at understanding the beliefs and attitudes of the population towards air pollution, its levels, causes, health impacts and possible mitigation and protection actions. The study sample consisted of members of the general population, between 18 and 65 years living in Barcelona. The analysis of the group discussion indicates that there is little awareness among participants about air pollution risks. The causes of air pollution are relatively known but there is little knowledge about pollution levels and types of pollutants. We found a low level of perceived personal risk associated to air pollution that coexists with a general awareness of the health impacts of air pollution, a low level of concern about the problem and a low level of personal involvement in mitigation and self protection measures. Participants reported no use of existing information services about air pollution. (Author)

  6. Study protocol: the effects of air pollution exposure and chronic respiratory disease on pneumonia risk in urban Malawian adults--the Acute Infection of the Respiratory Tract Study (The AIR Study).

    Science.gov (United States)

    Jary, Hannah; Mallewa, Jane; Nyirenda, Mulinda; Faragher, Brian; Heyderman, Robert; Peterson, Ingrid; Gordon, Stephen; Mortimer, Kevin

    2015-08-20

    Pneumonia is the 2nd leading cause of years of life lost worldwide and is a common cause of adult admissions to hospital in sub-Saharan Africa. Risk factors for adult pneumonia are well characterised in developed countries, but are less well described in sub-Saharan Africa where HIV is a major contributing factor. Exposure to indoor and outdoor air pollution is high, and tobacco smoking prevalence is increasing in sub-Saharan Africa, yet the contribution of these factors to the burden of chronic respiratory diseases in sub-Saharan Africa remains poorly understood. Furthermore, the extent to which the presence of chronic respiratory diseases and exposure to air pollution contribute to the burden of pneumonia is not known. The Acute Infection of the Respiratory Tract Study (The AIR Study) is a case-control study to identify preventable risk factors for adult pneumonia in the city of Blantyre, Malawi. Cases will be adults admitted with pneumonia, recruited from Queen Elizabeth Central Hospital, the largest teaching hospital in Malawi. Controls will be adults without pneumonia, recruited from the community. The AIR Study will recruit subjects and analyse data within strata defined by positive and negative HIV infection status. All participants will undergo thorough assessment for a range of potential preventable risk factors, with an emphasis on exposure to air pollution and the presence of chronic respiratory diseases. This will include collection of questionnaire data, clinical samples (blood, urine, sputum and breath samples), lung function data and air pollution monitoring in their home. Multivariate analysis will be used to identify the important risk factors contributing to the pneumonia burden in this setting. Identification of preventable risk factors will justify research into the effectiveness of targeted interventions to address this burden in the future. The AIR Study is the first study of radiologically confirmed pneumonia in which air pollution exposure

  7. Compressed air energy storage with waste heat export: An Alberta case study

    International Nuclear Information System (INIS)

    Safaei, Hossein; Keith, David W.

    2014-01-01

    Highlights: • Export of compression waste heat from CAES facilities for municipal heating can be profitable. • D-CAES concept has a negative abatement cost of −$40/tCO 2 e under the studied circumstances. • Economic viability of D-CAES highly depends on distance between air storage site and heat load. - Abstract: Interest in compressed air energy storage (CAES) technology has been renewed driven by the need to manage variability form rapidly growing wind and solar capacity. Distributed CAES (D-CAES) design aims to improve the efficiency of conventional CAES through locating the compressor near concentrated heating loads so capturing additional revenue through sales of compression waste heat. A pipeline transports compressed air to the storage facility and expander, co-located at some distance from the compressor. The economics of CAES are strongly dependant on electricity and gas markets in which they are embedded. As a case study, we evaluated the economics of two hypothetical merchant CAES and D-CAES facilities performing energy arbitrage in Alberta, Canada using market data from 2002 to 2011. The annual profit of the D-CAES plant was $1.3 million more on average at a distance of 50 km between the heat load and air storage sites. Superior economic and environmental performance of D-CAES led to a negative abatement cost of −$40/tCO 2 e. We performed a suite of sensitivity analyses to evaluate the impact of size of heat load, size of air storage, ratio of expander to compressor size, and length of pipeline on the economic feasibility of D-CAES

  8. James Bay air quality study : report on the results of field monitoring in 2007

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2008-02-08

    An air quality study in James Bay was conducted, in order to establish general levels of pollutants in outdoor air in the James Bay area of Victoria, British Columbia. The primary sources of air pollution in the area include light duty and heavy duty vehicle traffic, helicopters, floatplanes, and marine vessels such as cruise ships, passenger ferries, commercial fishing and whale watching boats, and recreation motorboats. Air quality monitoring represented the first phase of the project. The second phase involved a detailed pollutant dispersion model including all emission sources. This report described the use of sampling equipment and the measurement of nitric oxide, nitrogen dioxide, sulfur dioxide, fine particulate matter and contributing sources, and volatile organic compounds, specifically benzene, toluene, ethylbenzene/xylene and naphthalene. Supporting data, including traffic counts, wind speed and direction, precipitation, and cruise ship schedules were collected to assist in the interpretation of the field monitoring results. For each of these pollutants, the report provided responses to several questions, such as defining each pollutant; describing the sources of each pollutant in the James Bay neighbourhood; presenting the results of the field monitoring; discussing the limitations of the monitoring equipment and sampling design; interpreting the results; comparing monitored levels to those measured at other times or locations; and comparing monitored levels to air quality standards or guidelines. Conclusions about each pollutant were presented. It was concluded that phase 2 pollutant dispersion modelling should include estimates of 1-hour, 24-hour, and seasonal average pollutant levels at varying elevations above ground level, with a focus on residential apartment buildings in the study area. 5 tabs., 52 figs., 7 appendices.

  9. Suicide risk in relation to air pollen counts: a study based on data from Danish registers

    Science.gov (United States)

    Qin, Ping; Waltoft, Berit L; Mortensen, Preben B; Postolache, Teodor T

    2013-01-01

    Objectives Since the well-observed spring peak of suicide incidents coincides with the peak of seasonal aeroallergens as tree-pollen, we want to document an association between suicide and pollen exposure with empirical data from Denmark. Design Ecological time series study. Setting Data on suicide incidents, air pollen counts and meteorological status were retrieved from Danish registries. Participants 13 700 suicide incidents over 1304 consecutive weeks were obtained from two large areas covering 2.86 million residents. Primary and secondary outcome measures Risk of suicide associated with pollen concentration was assessed using a time series Poisson-generalised additive model. Results We noted a significant association between suicide risk and air pollen counts. A change of pollen counts levels from 0 to ‘10–suicides in the population, and from 0 to ‘30–100’ grains, a relative risk of 1.132. The observed association remained significant after controlling for effects of region, calendar time, temperature, cloud cover and humidity. Meanwhile, we observed a significant sex difference that suicide risk in men started to rise when there was a small increase of air pollen, while the risk in women started to rise until pollen grains reached a certain level. High levels of pollen had slightly stronger effect on risk of suicide in individuals with mood disorder than those without the disorder. Conclusions The observed association between suicide risk and air pollen counts supports the hypothesis that aeroallergens, acting as immune triggers, may precipitate suicide. PMID:23793651

  10. Material Selection for Competition–A Case Study for Air Coolers

    Directory of Open Access Journals (Sweden)

    Luma A. H. Al Kindi

    2018-02-01

    Full Text Available Competition is one of the most important challenges that is facing the marketing of industrial products in today's markets. In this research study of the impact of material selection factor for air coolers of different materials is applied. Investigation on the air cooler windows which are part of the body of air coolers is conducted. Corrosion resistance, thermal conductivity, strength of material, weight, shape, cost and manufacturing process are the factors that are applied and calculated on three types of materials Aluminum, Galvanized steel and polypropylene. The physical properties of the three mentioned materials are used to calculate Merit Index .The corrosion average, according to Tafel Method depending the corrosion current and adopting contactors for the anodic and cathodic metals behaviors is performed. ANSYS is adopted using the three samples for the selected materials Aluminum, Galvanized steel and polypropylene to measure maximum stress and deflection are measured. Accordingly, the results are compared to choose the best alternative. It is observed that the polypropylene is the best choice depending three factors while the aluminum material is better depending two factors and the galvanized steel is regarded as the best in only one factor, the rest factors are identical when choosing  an alternative material for manufacturing the air cooler windows.

  11. Product lifetime, energy efficiency and climate change: A case study of air conditioners in Japan.

    Science.gov (United States)

    Nishijima, Daisuke

    2016-10-01

    This study proposed a modelling technique for estimating life-cycle CO2 emissions of durable goods by considering changes in product lifetime and energy efficiency. The stock and flow of durable goods was modelled by Weibull lifetime distributions and the trend in annual energy efficiency (i.e., annual electricity consumption) of an "average" durable good was formulated as a reverse logistic curve including a technologically critical value (i.e., limit energy efficiency) with respect to time. I found that when the average product lifetime is reduced, there is a trade-off between the reduction in emissions during product use (use phase), due to the additional purchases of new, more energy-efficient air conditioners, and the increase in emissions arising from the additional production of new air conditioners stimulated by the reduction of the average product lifetime. A scenario analysis focused on residential air conditioners in Japan during 1972-2013 showed that for a reduction of average lifetime of 1 year, if the air conditioner energy efficiency limit can be improved by 1.4% from the estimated current efficiency level, then CO2 emissions can be reduced by approximately the same amount as for an extension of average product lifetime of 1 year. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Air pollutant characterization in Tula industrial corridor, Central Mexico, during the MILAGRO study.

    Science.gov (United States)

    Sosa, G; Vega, E; González-Avalos, E; Mora, V; López-Veneroni, D

    2013-01-01

    Pollutant emissions and their contribution to local and regional air quality at the industrial area of Tula were studied during a four-week period as part of the MILAGRO initiative. A recurrent shallow stable layer was observed in the morning favoring air pollutants accumulation in the lower 100 m atmospheric layer. In the afternoon the mixing layer height reached 3000 m, along with a featuring low level jet which was responsible of transporting air pollutants at regional scales. Average PM10 at Jasso (JAS) and Tepeji (TEP) was 75.1 and 36.8 μ g/m(3), respectively while average PM2.5 was 31.0 and 25.7 μ g/m(3). JAS was highly impacted by local limestone dust, while TEP was a receptor of major sources of combustion emissions with 70% of the PM10 constituted by PM2.5. Average hourly aerosol light absorption was 22 Mm(-1), while aerosol scattering (76 Mm(-1)) was higher compared to a rural site but much lower than at Mexico City. δ(13)C values in the epiphyte Tillandsia recurvata show that the emission plume directly affects the SW sector of Mezquital Valley and is then constrained by a mountain range preventing its dispersion. Air pollutants may exacerbate acute and chronic adverse health effects in this region.

  13. Air Pollutant Characterization in Tula Industrial Corridor, Central Mexico, during the MILAGRO Study

    Directory of Open Access Journals (Sweden)

    G. Sosa

    2013-01-01

    Full Text Available Pollutant emissions and their contribution to local and regional air quality at the industrial area of Tula were studied during a four-week period as part of the MILAGRO initiative. A recurrent shallow stable layer was observed in the morning favoring air pollutants accumulation in the lower 100 m atmospheric layer. In the afternoon the mixing layer height reached 3000 m, along with a featuring low level jet which was responsible of transporting air pollutants at regional scales. Average PM10 at Jasso (JAS and Tepeji (TEP was 75.1 and 36.8 μg/m3, respectively while average PM2.5 was 31.0 and 25.7 μg/m3. JAS was highly impacted by local limestone dust, while TEP was a receptor of major sources of combustion emissions with 70% of the PM10 constituted by PM2.5. Average hourly aerosol light absorption was 22 Mm−1, while aerosol scattering (76 Mm−1 was higher compared to a rural site but much lower than at Mexico City. δ13C values in the epiphyte Tillandsia recurvata show that the emission plume directly affects the SW sector of Mezquital Valley and is then constrained by a mountain range preventing its dispersion. Air pollutants may exacerbate acute and chronic adverse health effects in this region.

  14. A study on the sound quality evaluation model of mechanical air-cleaners

    DEFF Research Database (Denmark)

    Ih, Jeong-Guon; Jang, Su-Won; Jeong, Cheol-Ho

    2009-01-01

    In operating the air-cleaner for a long time, people in a quiet enclosed space expect low sound at low operational levels for a routine cleaning of air. However, in the condition of high operational levels of the cleaner, a powerful yet nonannoying sound is desired, which is connected to a feeling...... of an immediate cleaning of pollutants. In this context, it is important to evaluate and design the air-cleaner noise to satisfy such contradictory expectations from the customers. In this study, a model for evaluating the sound quality of air-cleaners of mechanical type was developed based on objective...... and subjective analyses. Sound signals from various aircleaners were recorded and they were edited by increasing or decreasing the loudness at three wide specific-loudness bands: 20-400 Hz (0-3.8 barks), 400-1250 Hz (3.8-10 barks), and 1.25- 12.5 kHz bands (10-22.8 barks). Subjective tests using the edited...

  15. Retrieval process development and enhancements FY96 pulsed-air mixer testing and deployment study

    International Nuclear Information System (INIS)

    Powell, M.R.; Hymas, C.R.

    1996-08-01

    Millions of gallons of radioactive wastes resides in underground tanks at US Department of Energy sites. The waste was generated primarily by the processing of nuclear fuel elements to remove fissile radionuclides for use in atomic weapons. Plans call for the waste to be removed from the tanks and processed to create immobile waste forms, which will be stored to prevent release to the environment. The consistency of the waste ranges from liquid, to slurry, to sticky sludge, to hard saltcake. a variety of waste- retrieval and processing methods are being evaluated and implemented. One such method is pulsed-air mixing, which is the subject of this report. Pulsed-air mixing equipment has been successfully applied to a number of difficult mixing applications in various chemical-process industries. Most previous applications involved the mixing of particle-free viscous fluids. The study described in this report was preformed to improve the understanding of how pulsed-air mixing applies to slurries. This document describes work conducted to evaluate the potential application of pulsed-air mixers to the slurry- mixing needs of the US Department of Energy's waste-retrieval programs

  16. A preliminary study on HTGR with air-cooled condenser at Riyadh, Saudi Arabia

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Jonghwa; Lee, Wonjae [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-05-15

    N GNP reactor plant adopted a Rank in steam cycle for early deployment and for reducing R and D risk and cost. Original plant design is based on a wet cooling tower with wet bulb temperature of 34 .deg. C. This cooling environment may be sufficient for most area in North America. However, we should consider air temperature of 45 .deg. C and no available cooling water for any site near Riyadh, Saudi Arabia. A plausible option in such arid area is using an air-cooled condenser(ACC) which is widely used in a combined cycle plant in arid region. ACC is also suitable for freezing area such as northern territory or high elevation remote area. We have studied impact of the cooling method on the power generation efficiency and the annual average power production referencing N GNP steam turbine. Even though condenser split is assumed to be the same between ACC and wet cooling tower, large difference in air temperature and wet bulb temperature makes large efficiency loss in the ACC. The ACC efficiency is lower than that of the wet cooling tower by 1.12%. To make up this loss, we proposed the variable steam extraction rates operation. An air cooled condenser is a practical.

  17. Sulfur hexafluoride purification from mixtures with air: a process feasibility study

    International Nuclear Information System (INIS)

    Perona, J.J.; Watson, J.S.

    1979-10-01

    Studies were made of the purification of SF 6 vapor contaminated with air for application at the Holifield Heavy-Ion Research Facility. Liquefaction appears to be a good method for recovering about 90% of the SF 6 if it is badly contaminated (15% air), and an even greater fraction can be recovered from mixtures containing less air. In cases where liquefaction is insufficient by itself, adsorption of SF 6 on activated carbon at -50 0 F is promising. Two carbon beds, each containing about 500 lb of carbon, should be sufficient. The refrigeration system for liquefaction and adsorption would have a capacity of about 2 tons. As an alternative, the use of molecular sieves to trap out the air was investigated, but such a bed would require at least 15,000 lb of molecular sieves and very long cycle times. A large-scale desublimer was also investigated and appears workable, but it would require some development effort before the design could proceed with confidence

  18. Study of a vapor-compression air-conditioning system for jetliners

    Energy Technology Data Exchange (ETDEWEB)

    Roeyttae, P.

    2009-07-01

    Most modern passenger aeroplanes use air cycle cooling. A high-speed air cycle is a reliable and light option, but not very efficient. This thesis presents research work done to design a novel vapour cooling cycle for aeroplanes. Due to advancements in high-speed permanent magnet motors, the vapour cycle is seen as a competitive option for the air cycle in aeroplanes. The aerospace industry placews tighter demands on the weight, reliability and environmental effects of the machinery than those met by conventional chillers, and thus modifications to conventional design are needed. The thesis is divided into four parts: the initial screening of the working fluid, 1-D design and performance values of the compressor, 1-D off-design value predictions of the compressor and the 3-D design of the compressor. The R24fa was selected as the working fluid based the study. The off-design range of the compressor was predicted to be wide and suitable for the application. The air-conditioning system developed is considerably smaller than previous designs using centrifugal compressors. (orig.)

  19. Study of the morphology of corrosion features of natural graphite oxidised by dry and humid air

    International Nuclear Information System (INIS)

    Senevat, Jean

    1965-12-01

    The author reports a study which aimed at highlighting the morphology differences between corrosion features which affect flakes of natural graphite oxidised by dry air and by humid air. The study is based on observations made by optical and transmission electronic microscopy, this last one being performed on replicates. As the so-called 'Hennig' replicates did not result in a sufficient resolution of corrosion feature details, another method has been developed. Three classes of samples (in relationship with the rate of impurities present in samples) have been studied. Flakes have thus been sorted and each flake has then been oxidised at different wear rates. This highlights the influence of damages created by impurities in the lattice [fr

  20. Studies on molecular sieves for the removal of moisture from air stream

    International Nuclear Information System (INIS)

    Kalra, S.; Ramarathinam, K.; Khan, A.A.

    1975-01-01

    Studies on molecular sieves were taken up with a view to provide sufficient experimental data for the design of an adsorbent bed for the removal of moisture to very low level from air stream containing traces of radioactive xenon and krypton, so that delay of xenon and krypton on activated charcoal columns can take place with a higher dynamic adsorption coefficient. Experimental studies included the evaluation of molecular sieves for their moisture removal efficiencies at different face velocities and different bed thicknesses. Adsorption capacity at removal efficiency of 98.5% was determined for molecular sieves type 4A of local and foreign origin. For local molecular sieves type 4A, adsorption capacity at 95% removal efficiency was found out at lower moisture contents of air streams. Regeneration characteristics of a saturated bed were also studied on local molecular sieves type 4A. (author)

  1. Study of Stable Cathodes and Electrolytes for High Specific Density Lithium-Air Battery

    Science.gov (United States)

    Hernandez-Lugo, Dionne M.; Wu, James; Bennett, William; Ming, Yu; Zhu, Yu

    2015-01-01

    Future NASA missions require high specific energy battery technologies, greater than 400 Wh/kg. Current NASA missions are using "state-of-the-art" (SOA) Li-ion batteries (LIB), which consist of a metal oxide cathode, a graphite anode and an organic electrolyte. NASA Glenn Research Center is currently studying the physical and electrochemical properties of the anode-electrolyte interface for ionic liquid based Li-air batteries. The voltage-time profiles for Pyr13FSI and Pyr14TFSI ionic liquids electrolytes studies on symmetric cells show low over-potentials and no dendritic lithium morphology. Cyclic voltammetry measurements indicate that these ionic liquids have a wide electrochemical window. As a continuation of this work, sp2 carbon cathode and these low flammability electrolytes were paired and the physical and electrochemical properties were studied in a Li-air battery system under an oxygen environment.

  2. Analysis of indoor air quality data from East Tennessee field studies

    International Nuclear Information System (INIS)

    Dudney, C.S.; Hawthorne, A.R.

    1985-08-01

    This report presents the results of follow-up experimental activities and data analyses of an indoor air quality study conducted in 40 East Tennessee homes during 1982-1983. Included are: (1) additional experimental data on radon levels in all homes, repeat measurements in house No. 7 with elevated formaldehyde levels, and energy audit information on the participants' homes; (2) further data analyses, especially of the large formaldehyde data base, to ascertain relationships of pollutant levels vs environmental factors and house characteristics; (3) indoor air quality data base considerations and development of the study data base for distribution on magnetic media for both mainframe and desktop computer use; and (4) identification of design and data collection considerations for future field studies. A bibliography of additional publications related to this effort is also presented

  3. The absolute risk of venous thrombosis after air travel: a cohort study of 8,755 employees of international organisations

    NARCIS (Netherlands)

    Kuipers, Saskia; Cannegieter, Suzanne C.; Middeldorp, Saskia; Robyn, Luc; Buller, Harry R.; Rosendaal, Frits R.

    2007-01-01

    BACKGROUND: The risk of venous thrombosis is approximately 2- to 4-fold increased after air travel, but the absolute risk is unknown. The objective of this study was to assess the absolute risk of venous thrombosis after air travel. METHODS AND FINDINGS: We conducted a cohort study among employees

  4. A Unified Spatiotemporal Modeling Approach for Predicting Concentrations of Multiple Air Pollutants in the Multi-Ethnic Study of Atherosclerosis and Air Pollution

    Science.gov (United States)

    Olives, Casey; Kim, Sun-Young; Sheppard, Lianne; Sampson, Paul D.; Szpiro, Adam A.; Oron, Assaf P.; Lindström, Johan; Vedal, Sverre; Kaufman, Joel D.

    2014-01-01

    Background: Cohort studies of the relationship between air pollution exposure and chronic health effects require predictions of exposure over long periods of time. Objectives: We developed a unified modeling approach for predicting fine particulate matter, nitrogen dioxide, oxides of nitrogen, and black carbon (as measured by light absorption coefficient) in six U.S. metropolitan regions from 1999 through early 2012 as part of the Multi-Ethnic Study of Atherosclerosis and Air Pollution (MESA Air). Methods: We obtained monitoring data from regulatory networks and supplemented those data with study-specific measurements collected from MESA Air community locations and participants’ homes. In each region, we applied a spatiotemporal model that included a long-term spatial mean, time trends with spatially varying coefficients, and a spatiotemporal residual. The mean structure was derived from a large set of geographic covariates that was reduced using partial least-squares regression. We estimated time trends from observed time series and used spatial smoothing methods to borrow strength between observations. Results: Prediction accuracy was high for most models, with cross-validation R2 (R2CV) > 0.80 at regulatory and fixed sites for most regions and pollutants. At home sites, overall R2CV ranged from 0.45 to 0.92, and temporally adjusted R2CV ranged from 0.23 to 0.92. Conclusions: This novel spatiotemporal modeling approach provides accurate fine-scale predictions in multiple regions for four pollutants. We have generated participant-specific predictions for MESA Air to investigate health effects of long-term air pollution exposures. These successes highlight modeling advances that can be adopted more widely in modern cohort studies. Citation: Keller JP, Olives C, Kim SY, Sheppard L, Sampson PD, Szpiro AA, Oron AP, Lindström J, Vedal S, Kaufman JD. 2015. A unified spatiotemporal modeling approach for predicting concentrations of multiple air pollutants in the Multi

  5. Solar Air Collectors for Space Heating and Ventilation Applications—Performance and Case Studies under Romanian Climatic Conditions

    Directory of Open Access Journals (Sweden)

    Sanda Budea

    2014-06-01

    Full Text Available Solar air collectors have various applications: on the one hand, they can be used for air heating in cold seasons; on the other hand they can be used in summer to evacuate the warm and polluted air from residential, offices, industrial, and commercial buildings. The paper presents experimental results of a solar collector air, under the climatic conditions of the Southeastern Europe. The relationships between the direct solar irradiation, the resulting heat flow, the air velocity at the outlet, the air flow rate, the nominal regime of the collector and the efficiency of conversion of solar energy into thermal energy are all highlighted. Thus, it was shown that after a maximum 50 min, solar air collectors, with baffles and double air passage can reach over 50% efficiency for solar irradiation of 900–1000 W/m2. The article also presents a mathematical model and the results of a computational program that allows sizing solar collectors for the transfer of air, with the purpose of improving the natural ventilation of buildings. The article is completed with case studies, sizing the area to be covered with solar collectors, to ensure ventilation of a house with two floors or for an office building. In addition, the ACH (air change per hour coefficient was calculated and compared.

  6. Factors influencing time-location patterns and their impact on estimates of exposure: the Multi-Ethnic Study of Atherosclerosis and Air Pollution (MESA Air).

    Science.gov (United States)

    Spalt, Elizabeth W; Curl, Cynthia L; Allen, Ryan W; Cohen, Martin; Williams, Kayleen; Hirsch, Jana A; Adar, Sara D; Kaufman, Joel D

    2016-06-01

    We assessed time-location patterns and the role of individual- and residential-level characteristics on these patterns within the Multi-Ethnic Study of Atherosclerosis and Air Pollution (MESA Air) cohort and also investigated the impact of individual-level time-location patterns on individual-level estimates of exposure to outdoor air pollution. Reported time-location patterns varied significantly by demographic factors such as age, gender, race/ethnicity, income, education, and employment status. On average, Chinese participants reported spending significantly more time indoors and less time outdoors and in transit than White, Black, or Hispanic participants. Using a tiered linear regression approach, we predicted time indoors at home and total time indoors. Our model, developed using forward-selection procedures, explained 43% of the variability in time spent indoors at home, and incorporated demographic, health, lifestyle, and built environment factors. Time-weighted air pollution predictions calculated using recommended time indoors from USEPA overestimated exposures as compared with predictions made with MESA Air participant-specific information. These data fill an important gap in the literature by describing the impact of individual and residential characteristics on time-location patterns and by demonstrating the impact of population-specific data on exposure estimates.

  7. Locally derived traffic-related air pollution and fetal growth restriction: a retrospective cohort study.

    Science.gov (United States)

    Pereira, Gavin; Cook, Angus G; Haggar, Fatima; Bower, Carol; Nassar, Natasha

    2012-11-01

    Fetal growth restriction has been inconsistently associated with maternal exposure to elevated levels of traffic-related air pollution. We investigated the relationship between an individualised measure of fetal growth and maternal exposure to a specific marker for traffic-related air pollution. We estimated maternal residential exposure to a marker for traffic-related air pollution (nitrogen dioxide, NO2) during pregnancy for 23,452 births using temporally adjusted land-use regression. Logistic regression was used to investigate associations with small for gestational age and sex (SGA) and fetal growth restriction, defined as proportion of optimal birth weight (POBW) below the 10th percentile. Sub-populations investigated were: women who spent most time at home, women who did not move house, women with respiratory or circulatory morbidity, women living in low/middle/high socio-economic areas, women who delivered before 37 weeks gestation, and women who delivered from 37 weeks gestation. An IQR increase in traffic-related air pollution in the second trimester across all women was associated with an OR of 1.31 (95% CI 1.07 to 1.60) for fetal growth restriction. Effects on fetal growth restriction (low POBW) were highest among women who subsequently delivered before 37 weeks of gestation. Effects on SGA were highest among women who did not move house: OR 1.35 (95% CI 1.08 to 1.69). Larger effect sizes were observed for low POBW than for SGA. Exposure to traffic-related air pollution in mid to late pregnancy was associated with risk of SGA and low POBW in this study.

  8. Feasibility of Measuring Tobacco Smoke Air Pollution in Homes: Report from a Pilot Study

    Directory of Open Access Journals (Sweden)

    Laura Rosen

    2015-11-01

    Full Text Available Tobacco smoke air pollution (TSAP measurement may persuade parents to adopt smoke-free homes and thereby reduce harm to children from tobacco smoke in the home. In a pilot study involving 29 smoking families, a Sidepak was used to continuously monitor home PM2.5 during an 8-h period, Sidepak and/or Dylos monitors provided real-time feedback, and passive nicotine monitors were used to measure home air nicotine for one week. Feedback was provided to participants in the context of motivational interviews. Home PM2.5 levels recorded by continuous monitoring were not well-accepted by participants because of the noise level. Also, graphs from continuous monitoring showed unexplained peaks, often associated with sources unrelated to indoor smoking, such as cooking, construction, or outdoor sources. This hampered delivery of a persuasive message about the relationship between home smoking and TSAP. By contrast, immediate real-time PM2.5 feedback (with Sidepak or Dylos monitor was feasible and provided unambiguous information; the Dylos had the additional advantages of being more economical and quieter. Air nicotine sampling was complicated by the time-lag for feedback and questions regarding shelf-life. Improvement in the science of TSAP measurement in the home environment is needed to encourage and help maintain smoke-free homes and protect vulnerable children. Recent advances in the use of mobile devices for real-time feedback are promising and warrant further development, as do accurate methods for real-time air nicotine air monitoring.

  9. Feasibility study on naturally safe HTGR (NSHTR) for air ingress accident

    Energy Technology Data Exchange (ETDEWEB)

    Ohashi, Hirofumi, E-mail: ohashi.hirofumi@jaea.go.jp; Sato, Hiroyuki; Tachibana, Yukio; Kunitomi, Kazuhiko; Ogawa, Masuro

    2014-05-01

    A new design activity for an advanced reactor, referred to as a naturally safe high temperature gas-cooled reactor (NSHTR), has been launched by authors after the accident at the Fukushima Daiichi Nuclear Power Station. The concept of NSHTR is that the release of radioactive materials is kept at very low level and no harmful effect on people and the environment is ensured by only physical phenomena even in the absence of engineered safety features. At an air ingress accident, possible physical events that lead to the loss or degradation of the confinement function of the fuel-coating layers are the crack of the coatings caused by the explosion of carbon monoxide (CO) produced by the graphite oxidation and failure of the coatings by melting or sublimation caused by core heat up due to the reaction heat of the graphite oxidation. In this study, the CO concentration and the heat generated by graphite oxidation inside the circular tube were evaluated parametrically using a steady-state one-dimensional model to confirm the feasibility of NSHTR at a severe condition of the air ingress accident (i.e., a massive air ingress by simultaneous rupture of two primary pipes). It was confirmed that the CO concentration at the outlet of coolant channel can be maintained below the explosion limit due to the reaction with oxygen in the air, and the reaction heat can be removed with the decay heat by physical phenomena under certain conditions of the coolant channel geometry without any engineered safety features. The results revealed that the design of NSHTR is technically feasible in terms of the suppression of the CO explosion and the heat removal of the reaction heat at the air ingress accident.

  10. Experimental and numerical study of an evaporatively-cooled condenser of air-conditioning systems

    International Nuclear Information System (INIS)

    Islam, M.R.; Jahangeer, K.A.; Chua, K.J.

    2015-01-01

    The performance of an air-conditioning unit with evaporately-cooled condenser coil is studied experimentally and numerically. An experimental setup is fabricated by retrofitting a commercially available air-conditioning unit and installing comprehensive measuring sensors and controllers. Experimental result shows that the COP (Coefficient of Performance) of the evaporately-cooled air-conditioning unit increases by about 28% compared to the conventional air cooled air-conditioning unit. To analyze the heat and mass transfer processes involved in the evaporately-cooled condenser, a detailed theoretical model has been developed based on the fluid flow characteristics of the falling film and the thermodynamic aspect of the evaporation process. Simulated results agree well with experimental data. The numerical model provides new insights into the intrinsic links between operating variables and heat transfer characteristics of water film in evaluating the performance of evaporatively-cooled condenser system. Two heat transfer coefficients, namely, wall to bulk and bulk to interface are introduced and computed from the simulation results under different operating conditions. Finally, the overall heat transfer coefficient for the water film is computed and presented as a function of dimensionless variables which can conveniently be employed by engineers to design and analyze high performance evaporatively-cooled heat exchangers. - Highlights: • Performance of evaporatively-cooled condenser is investigated. • Local convective heat transfer coefficients of water film are determined. • Thermal resistance of water film is negligible. • Heat transfer with evaporated vapor plays significant role on performance. • Better condenser performance translates to an improvement in COP

  11. Air Pollution and Human Health in Kolkata, India: A Case Study

    Directory of Open Access Journals (Sweden)

    Md. Senaul Haque

    2017-10-01

    Full Text Available Urban air quality in most megacities has been found to be critical and Kolkata Metropolitan City is no exception to this. An analysis of ambient air quality in Kolkata was done by applying the Exceedance Factor (EF method, where the presence of listed pollutants’ (RPM, SPM, NO2, and SO2 annual average concentration are classified into four different categories; namely critical, high, moderate, and low pollution. Out of a total of 17 ambient air quality monitoring stations operating in Kolkata, five fall under the critical category, and the remaining 12 locations fall under the high category of NO2 concentration, while for RPM, four record critical, and 13 come under the high pollution category. The causes towards the high concentration of pollutants in the form of NO2 and RPM have been identified in earlier studies as vehicular emission (51.4%, followed by industrial sources (24.5% and dust particles (21.1%. Later, a health assessment was undertaken with a structured questionnaire at some nearby dispensaries which fall under areas with different ambient air pollution levels. Three dispensaries have been surveyed with 100 participants. It shows that respondents with respiratory diseases (85.1% have outnumbered waterborne diseases (14.9% and include acute respiratory infections (ARI (60%, chronic obstructive pulmonary diseases (COPD (7.8%, upper track respiratory infection (UTRI (1.2%, Influenza (12.7%, and acid fast bacillus (AFB (3.4%. Although the pollution level has been recorded as critical, only 39.3% of the respondents have felt that outdoor (air pollution has affected their health.

  12. An Integrative Study of Photochemical Air Pollution in Hong Kong: an Overview

    Science.gov (United States)

    Wang, T.

    2014-12-01

    Hong Kong is situated in the Pearl River delta of Southern China. This region has experienced phenomenal economic growth in the past 30 years. Emissions of large amount of pollutants from urban areas and various industries coupled with subtropical climate have led to frequent occurrences of severe photochemical air pollution. Despite the long-term control efforts of the Hong Kong government, the atmospheric levels of ozone have been increasing in the past decade. To obtain an updated and more complete understanding of photochemical smog, an integrative study has been conducted during 2010-2014. Several intensive measurement campaigns were carried out at urban, suburban and rural sites in addition to the routine observations at fourteen air quality monitoring stations in Hong Kong. Meteorological, photochemical, and chemical-transport modeling studies were conducted to investigate the causes/processes of elevated photochemical pollution . The main activities of this study were to (1) examine the situation and trends of photochemical air pollution in Hong Kong, (2) understand some underlying chemical processes in particular the poorly-understood heterogeneous processes of reactive nitrogen oxides, (3) quantify the local, regional, and super-regional contributions to the ozone pollution in Hong Kong, and (4) review the control policy and make further recommendations based on the science. This paper will give an overview of this study and present some key results on the trends and chemistry of the photochemical pollution in this polluted subtropical region.

  13. Indoor air quality in urban and rural kindergartens: short-term studies in Silesia, Poland.

    Science.gov (United States)

    Błaszczyk, Ewa; Rogula-Kozłowska, Wioletta; Klejnowski, Krzysztof; Kubiesa, Piotr; Fulara, Izabela; Mielżyńska-Švach, Danuta

    2017-01-01

    More than 80% of people living in urban areas who monitor air pollution are exposed to air quality levels that exceed limits defined by the World Health Organization (WHO). Although all regions of the world are affected, populations in low-income cities are the most impacted. According to average annual levels of fine particulate matter (PM2.5, ambient particles with aerodynamic diameter of 2.5 μm or less) presented in the urban air quality database issued by WHO in 2016, as many as 33 Polish cities are among the 50 most polluted cities in the European Union (EU), with Silesian cities topping the list. The aim of this study was to characterize the indoor air quality in Silesian kindergartens based on the concentrations of gaseous compounds (SO 2 , NO 2 ), PM2.5, and the sum of 15 PM2.5-bound polycyclic aromatic hydrocarbons (PAHs), including PM2.5-bound benzo(a)pyrene (BaP), as well as the mutagenic activity of PM2.5 organic extracts in Salmonella assay (strains: TA98, YG1024). The assessment of the indoor air quality was performed taking into consideration the pollution of the atmospheric air (outdoor). I/O ratios (indoor/outdoor concentration) for each investigated parameter were also calculated. Twenty-four-hour samples of PM2.5, SO 2 , and NO 2 were collected during spring in two sites in southern Poland (Silesia), representing urban and rural areas. Indoor samples were taken in naturally ventilated kindergartens. At the same time, in the vicinity of the kindergarten buildings, the collection of outdoor samples of PM2.5, SO 2 , and NO 2 was carried out. The content of BaP and the sum of 15 studied PAHs was determined in each 24-h sample of PM2.5 (indoor and outdoor). In the urban site, statistically lower concentrations of SO 2 and NO 2 were detected indoors compared to outdoors, whereas in the rural site, such a relationship was observed only for NO 2 . No statistically significant differences in the concentrations of PM2.5, PM2.5-bound BaP, and Σ15 PAHs

  14. An experimental study of the air-side particulate fouling in finned-tube heat exchangers of air conditioners through accelerated tests

    International Nuclear Information System (INIS)

    Ahn, Young Chull; Cho, Jae Min; Lee, Jae Keun; Lee, Hyun Uk; Ahn, Seung Phyo; Youn, Deok Hyun; Kang, Tae Wook; Ock, Ju Jo

    2003-01-01

    The air-side particulate fouling in the heat exchangers of HVAC applications degrades the performance of cooling capacity, pressure drop across a heat exchanger, and indoor air quality. Indoor and outdoor air contaminants foul heat exchangers. The purpose of this study is to investigate the fouling characteristics trough accelerated tests. The fouling characteristics are analyzed as functions of a dust concentration (1.28 and 3.84 g/m 3 ), a face velocity (0.5, 1.0, and 1.5 m/s), and a surface condition. The cooling capacity in the slitted finned-tube heat exchangers at the face velocity of 1 m/s decreases about 2% and the pressure drop increases up to 57%. The rate of build-up of fouling is observed to be 3 times slower for this three-fold reduction of dust concentration whilst still approaching the same asymptotic level

  15. Air Pollution Study in the Republic of Moldova Using Moss Biomonitoring Technique.

    Science.gov (United States)

    Zinicovscaia, Inga; Hramco, Constantin; Duliu, Octavian G; Vergel, Konstantin; Culicov, Otilia A; Frontasyeva, Marina V; Duca, Gheorghe

    2017-02-01

    Moss biomonitoring using the species Hypnum cupressiforme (Hedw.) and Pleurocarpous sp was applied to study air pollution in the Republic of Moldova. A total of 41 elements (Na, Mg, Al, Cl, K, Ca, Sc, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Br, Rb, Sr, Zr, Cd, Sb, Cs, Ba, La, Ce, Nd, Sm, Eu, Gd, Tb, Tm, Yb, Hf, Ta, W, Pb, Th, and U) were determined by instrumental epithermal neutron activation analysis and atomic absorption spectrometry. Principal component analysis was used to identify and characterize different pollution sources. Geographical distribution maps were prepared to point out the regions most affected by air pollution and relate this to potential sources of contamination. Median values of the elements studied were compared with data from the European moss biomonitoring program. The cities of Chisinau and Balti were determined to experience particular environmental stress.

  16. Chemo-ecological studies on plant indicators for low level air pollution

    Energy Technology Data Exchange (ETDEWEB)

    Katoh, Terutaka; Kasuya, Minoru; Kagamimori, Sadanobu (Toyama Medical and Pharmaceutical Univ. (Japan). Faculty of Medicine); Kozuka, Hiroshi; Kawano, Shoichi

    1991-05-01

    The effects of low level air pollution on Japanese Cedar (Cryptomeria japonica) have been studied in the surrounding area of two thermoelectric power stations newly constructed in a rural area, Fukui Prefecture, on the Japan Sea side of central Honshu, Japan. The degree of visual injury in Japanese Cedar, scored with six different categories, was examined in 1974 and 1977 respectively, covering the entire study area. A more complete monitoring has been conducted at eight permanent sites in Awara-cho since 1974. A dendrochronological study was also carried out to evaluate the effects of air pollution on the increment growth of Japanese Cedars. There were clear correlations between the distance from the power station and tree decline. Severe damage was observed, in general, within a 7 km radius from the power station. The localized injury of Japanese Cedar, along the flood plain of the two rivers, was also demonstrated. A rapid increase of injury was noted until through the late 1970's. The growth inhibition, during this period, was also revealed by tree ring analysis. Some recovery of tree vigor and increment growth was observed after the introduction of pollution control systems at the power station. Consistent relationships were demonstrated between the index of increment growth, i.e., standardized ring index, and the levels of SO{sub 2} and NO{sub 2}. Scarcely any correlation was observed between pH of rain water and the standardized ring index. Decreased levels of foliar tannin were observed in the Japanese Cedars growing in the polluted areas. The inhibition of the shikimate pathway, by air pollution, was suggested by biochemical studies. Increased predation damage was observed in the foliage of Japanese Cedars with low tannin levels. The predisposed effects of air pollution were discussed with special reference to the inhibition of the shikimate pathway. (author).

  17. Studies on curing effect of phosphite monomer by EB radiation in the air

    International Nuclear Information System (INIS)

    Xiao, B.; Zhou, Y.; Li, S.; Luo, M.; Wang, X.; Zhao, P.

    2000-01-01

    A new type phosphite active monomer was synthesized. The resisting oxygen inhibition effect of this monomer and the effects of irradiation dose and concentration of phosphite active monomer on curing were studied. At the same time, curing results were analysed, through gel content and IR spectrum. The excellent resisting oxygen inhibition result of this phosphite active monomer was shown by experiments. EB radiation curing in the air was successfully carried out by the phosphite active monomer. (author)

  18. Chemo-ecological studies on plant indicators for low level air pollution

    International Nuclear Information System (INIS)

    Katoh, Terutaka; Kasuya, Minoru; Kagamimori, Sadanobu; Kozuka, Hiroshi; Kawano, Shoichi.

    1991-01-01

    The effects of low level air pollution on Japanese Cedar (Cryptomeria japonica) have been studied in the surrounding area of two thermoelectric power stations newly constructed in a rural area, Fukui Prefecture, on the Japan Sea side of central Honshu, Japan. The degree of visual injury in Japanese Cedar, scored with six different categories, was examined in 1974 and 1977 respectively, covering the entire study area. A more complete monitoring has been conducted at eight permanent sites in Awara-cho since 1974. A dendrochronological study was also carried out to evaluate the effects of air pollution on the increment growth of Japanese Cedars. There were clear correlations between the distance from the power station and tree decline. Severe damage was observed, in general, within a 7 km radius from the power station. The localized injury of Japanese Cedar, along the flood plain of the two rivers, was also demonstrated. A rapid increase of injury was noted until through the late 1970's. The growth inhibition, during this period, was also revealed by tree ring analysis. Some recovery of tree vigor and increment growth was observed after the introduction of pollution control systems at the power station. Consistent relationships were demonstrated between the index of increment growth, i.e., standardized ring index, and the levels of SO 2 and NO 2 . Scarcely any correlation was observed between pH of rain water and the standardized ring index. Decreased levels of foliar tannin were observed in the Japanese Cedars growing in the polluted areas. The inhibition of the shikimate pathway, by air pollution, was suggested by biochemical studies. Increased predation damage was observed in the foliage of Japanese Cedars with low tannin levels. The predisposed effects of air pollution were discussed with special reference to the inhibition of the shikimate pathway. (author)

  19. CFD based aerodynamic modeling to study flight dynamics of a flapping wing micro air vehicle

    Science.gov (United States)

    Rege, Alok Ashok

    The demand for small unmanned air vehicles, commonly termed micro air vehicles or MAV's, is rapidly increasing. Driven by applications ranging from civil search-and-rescue missions to military surveillance missions, there is a rising level of interest and investment in better vehicle designs, and miniaturized components are enabling many rapid advances. The need to better understand fundamental aspects of flight for small vehicles has spawned a surge in high quality research in the area of micro air vehicles. These aircraft have a set of constraints which are, in many ways, considerably different from that of traditional aircraft and are often best addressed by a multidisciplinary approach. Fast-response non-linear controls, nano-structures, integrated propulsion and lift mechanisms, highly flexible structures, and low Reynolds aerodynamics are just a few of the important considerations which may be combined in the execution of MAV research. The main objective of this thesis is to derive a consistent nonlinear dynamic model to study the flight dynamics of micro air vehicles with a reasonably accurate representation of aerodynamic forces and moments. The research is divided into two sections. In the first section, derivation of the nonlinear dynamics of flapping wing micro air vehicles is presented. The flapping wing micro air vehicle (MAV) used in this research is modeled as a system of three rigid bodies: a body and two wings. The design is based on an insect called Drosophila Melanogaster, commonly known as fruit-fly. The mass and inertial effects of the wing on the body are neglected for the present work. The nonlinear dynamics is simulated with the aerodynamic data published in the open literature. The flapping frequency is used as the control input. Simulations are run for different cases of wing positions and the chosen parameters are studied for boundedness. Results show a qualitative inconsistency in boundedness for some cases, and demand a better

  20. Road traffic noise, air pollution and myocardial infarction: a prospective cohort study.

    Science.gov (United States)

    Bodin, Theo; Björk, Jonas; Mattisson, Kristoffer; Bottai, Matteo; Rittner, Ralf; Gustavsson, Per; Jakobsson, Kristina; Östergren, Per-Olof; Albin, Maria

    2016-07-01

    Both road traffic noise and air pollution have been linked to cardiovascular disease. However, there are few prospective epidemiological studies available where both road traffic noise and air pollution have been analyzed simultaneously. The aim of this study was to investigate the relation between road traffic noise, air pollution and incident myocardial infarction in both current (1-year average) and medium-term (3-year average) perspective. This study was based on a stratified random sample of persons aged 18-80 years who answered a public health survey in Skåne, Sweden, in 2000 (n = 13,512). The same individuals received a repeated survey in 2005 and 2010. Diagnoses of myocardial infarction (MI) were obtained from medical records for both inpatient and outpatient specialized care. The endpoint was first MI during 2000-2010. Participants with prior myocardial infarction were excluded at baseline. Yearly average levels of noise (L DEN) and air pollution (NO x ) were estimated using geographic information system for residential address every year until censoring. The mean exposure levels for road traffic noise and air pollution in 2005 were L DEN 51 dB(A) and NO x 11 µg/m(3), respectively. After adjustment for individual confounders (age, sex, body mass index, smoking, education, alcohol consumption, civil status, year, country of birth and physical activity), a 10-dB(A) increase in current noise exposure did not increase the incidence rate ratio (IRR) for MI, 0.99 (95 % CI 0.86-1.14). Neither did a 10-μg/m(3) increase in current NO x increase the risk of MI, 1.02 (95 % CI 0.86-1.21). The IRR for MI associated with combined exposure to road traffic noise >55 dB(A) and NO x >20 µg/m(3) was 1.21 (95 % CI 0.90-1.64) compared to noise or air pollution at moderate average exposure levels.

  1. Air pollution and lung function among susceptible adult subjects: a panel study

    Directory of Open Access Journals (Sweden)

    Marconi Achille

    2006-05-01

    Full Text Available Abstract Background Adverse health effects at relatively low levels of ambient air pollution have consistently been reported in the last years. We conducted a time-series panel study of subjects with chronic obstructive pulmonary disease (COPD, asthma, and ischemic heart disease (IHD to evaluate whether daily levels of air pollutants have a measurable impact on the lung function of adult subjects with pre-existing lung or heart diseases. Methods Twenty-nine patients with COPD, asthma, or IHD underwent repeated lung function tests by supervised spirometry in two one-month surveys. Daily samples of coarse (PM10–2.5 and fine (PM2.5 particulate matter were collected by means of dichotomous samplers, and the dust was gravimetrically analyzed. The particulate content of selected metals (cadmium, chrome, iron, nickel, lead, platinum, vanadium, and zinc was determined by atomic absorption spectrometry. Ambient concentrations of nitrogen dioxide (NO2, carbon monoxide (CO, ozone (O3, and sulphur dioxide (SO2 were obtained from the regional air-quality monitoring network. The relationships between concentrations of air pollutants and lung function parameters were analyzed by generalized estimating equations (GEE for panel data. Results Decrements in lung function indices (FVC and/or FEV1 associated with increasing concentrations of PM2.5, NO2 and some metals (especially zinc and iron were observed in COPD cases. Among the asthmatics, NO2 was associated with a decrease in FEV1. No association between average ambient concentrations of any air pollutant and lung function was observed among IHD cases. Conclusion This study suggests that the short-term negative impact of exposure to air pollutants on respiratory volume and flow is limited to individuals with already impaired respiratory function. The fine fraction of ambient PM seems responsible for the observed effects among COPD cases, with zinc and iron having a potential role via oxidative stress. The

  2. Study of the Influence of an Air-Entraining Agent on the Rheology of Motars

    Directory of Open Access Journals (Sweden)

    Tebbal Nadia

    2018-01-01

    Experimental studies have been carried out to study the effect of air entrainment on compressive strength, density and ingredients of fresh concrete mix. During all the study, water cement ratio (w/c was maintained constant at 0.5. The results have shown substantial decreasing in water and mortar density followed with decreasing in compressive strength of mortar. The results of this study has given more promising to use it as a guide for mortar mix design to choose the most appropriate concrete mix design economically.

  3. Traffic-related air pollution increased the risk of Parkinson's disease in Taiwan: A nationwide study.

    Science.gov (United States)

    Lee, Pei-Chen; Liu, Li-Ling; Sun, Yu; Chen, Yu-An; Liu, Chih-Ching; Li, Chung-Yi; Yu, Hwa-Lung; Ritz, Beate

    2016-11-01

    Ambient air pollution has been associated with many health conditions, but little is known about its effects on neurodegenerative diseases, such as Parkinson's disease (PD). In this study, we investigated the influence of ambient air pollution on PD in a nationwide population-based case-control study in Taiwan. We identified 11,117 incident PD patients between 2007 and 2009 from the Taiwanese National Health Insurance Research Database and selected 44,468 age- and gender-matched population controls from the longitudinal health insurance database. The average ambient pollutant exposure concentrations from 1998 through the onset of PD were estimated using quantile-based Bayesian Maximum Entropy models. Basing from logistic regression models, we estimated the odds ratios (ORs) and 95% confidence intervals (CIs) of ambient pollutant exposures and PD risk. We observed positive associations between NO x , CO exposures, and PD. In multi-pollutant models, for NO x and CO above the 75th percentile exposure compared with the lowest percentile, the ORs of PD were 1.37 (95% CI=1.23-1.52) and 1.17 (95% CI=1.07-1.27), respectively. This study suggests that ambient air pollution exposure, especially from traffic-related pollutants such as NO x and CO, increases PD risk in the Taiwanese population. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Studi Eksperimen Pengaruh Dimensi Pipa Kapiler Pada Sistem Air Conditioning Dengan Pre-Cooling

    Directory of Open Access Journals (Sweden)

    Awan Satya Darmawan

    2017-01-01

    Full Text Available Penggunaan air conditioner semakin banyak digunakan pada kehidupan sehari-hari diiringi dengan harga jual energi yang semakin mahal. Pada studi eksperimen kali ini mencoba mengoptimalisasi dan menigkatkan efisiensi energi pada sistem air conditioner dengan cara menambahkan satu buah evaporator dan satu buah pre-cooling, dimana pre-cooling dimanfaatkan untuk memanaskan air yang nantinya akan digunakan untuk keperluan rumah tangga. Pada sistem pengkondisian udara yang telah dimodifikasi tersebut maka dilakukan studi eksperimen dengan variasi panjang pipa kapiler, diameter pipa kapiler d=0,054 in, dengan panjang kapiler 1 = 35 cm, kapiler 2 = 65 cm, kapiler 3 = 95 cm. Hasil yang didapat dari studi eksperimen kali ini adalah semakin bertambahnya panjang pipa kapiler, kapasitas pendinginan evaporator, kerja kompresor dan COP dari sistem juga akan semakin kecil dan juga mengakibatkan temperatur masuk evaporator akan semakin kecil, yang akan mengakibatkan efek pendinginan akan semakin besar. Pada variasi pipa kapiler terpendek 35 cm menghasilkan data kapasitas pendinginan total sebesar 2,25 kW, kerja kompresor 0,433 kW, temperatur masuk evaporator 7,26°C, COP sebesar 5,21 dan HRR sebesar 1,16. Sedangkan pada variasi pipa kapiler terpanjang 95 cm kapasitas pendinginan total sebesar 0,72 kW, kerja kompresor 0,332 kW, temperatur masuk evaporator 1,64°C, COP sebesar 4,35 dan HRR sebesar 1,26.

  5. Severity and Susceptibility Beliefs Associated with Urban Air Pollution: Results of a Qualitative Study

    International Nuclear Information System (INIS)

    Oltra, C.; Sala, R.

    2015-01-01

    In this report we present the results of a qualitative study based on recombined focus groups with lay citizens. The main objective is to analyze individuals’ beliefs on urban air pollution and perceived benefits and barriers of some self-protective actions, such as using special masks, avoidance of polluted streets, etc. The analytical framework on which the study is based is the Health Belief Model, whose basic idea is that it is more likely that individuals take actions to protect themselves if they think they are potentially susceptible to a serious threat to your health, if they think adopting certain actions has advantages, and if they think there are no significant barriers for such conduct. A secondary objective is to explore the perception of different existing materials to inform the public about air pollution. The results of the study are intended to contribute to the design of interventions aimed at reducing health impacts of urban air pollution and, specifically, to the design of messages in the context of information campaigns on health and environmental risk.

  6. The Association between Air Pollution and Population Health Risk for Respiratory Infection: A Case Study of Shenzhen, China.

    Science.gov (United States)

    Xia, Xiaolin; Zhang, An; Liang, Shi; Qi, Qingwen; Jiang, Lili; Ye, Yanjun

    2017-08-23

    Nowadays, most of the research on air pollution and its adverse effects on public health in China has focused on megacities and heavily-polluted regions. Fewer studies have focused on cities that are slightly polluted. Shenzhen used to have a favorable air environment, but its air quality has deteriorated gradually as a result of development in recent years. So far, no systematic investigations have been conducted on the adverse effects of air pollution on public health in Shenzhen. This research has applied a time series analysis model to study the possible association between different types of air pollution and respiratory hospital admission in Shenzhen in 2013. Respiratory hospital admission was divided into two categories for comparison analysis among various population groups: acute upper respiratory infection and acute lower respiratory infection. The results showed that short-term exposure to ambient air pollution was significantly associated with acute respiratory infection hospital admission in Shenzhen in 2013. Children under 14 years old were the main susceptible population of acute respiratory infection due to air pollution. PM 10 , PM 2.5 and NO₂ were the primary air pollutants threatening respiratory health in Shenzhen. Though air pollution level is generally relatively low in Shenzhen, it will benefit public health to control the pollution of particulate matter as well as other gaseous pollutants.

  7. Study of Mouthguard Design for Endurance and Air-Flow Intake

    Science.gov (United States)

    Zaman, I.; Rozlan, S. A. M.; Manshoor, B.; Ngali, M. Z.; Khalid, A.; Amin, N. A. M.

    2017-08-01

    Mouthguard is one of the important device for athletes. Wearing a mouthguard is a must to prevent them from any orofacial injuries occurs during their sport activities. Therefore, to make sure it is safe and comfort, a study on the mouthguard design is carried out to investigate the performance of the mouthguard, in term of stress distribution and air flow path by improving the pressure difference between ambient and the oral cavity pressure. A preliminary design has been study to simulate its total deformation and stress, in terms of Von Mises Stress by using ANSYS 15.0 Workbench. From the results, the critical parts are identified on the preliminary design and later being used to improve the design to the new one. By increasing the thickness of the preliminary design, the total deformation has been decreased for about 0.20 mm to 0.16 mm for the exerted external forces ranging from 50-500 N, whereas, for internal forces ranging from 100-600 N have reduced deformation from 0.24 mm to 1.44 mm. The simulation process is then followed by the air flow study in the oral cavity with an open mouth about 0.5 mm when the athlete is doing exercise with speed 4.43 m/s of air flow into a mouth. The finding indicates that the modified mouthguard has large value of velocity streamline compared to the preliminary design which is supported by significant pressure difference of 401.86 Pa, compared to 140.09 Pa of the preliminary design. Velocity stream line also shows that the higher speeds occur in the near mouthguard, that is, between the bottom surfaces of the mouthguard and the lower teeth. The results demonstrated that the thicker the mouthguard, the better it is for prevention but less in air flow distribution into the oral cavity.

  8. Time-location patterns of a diverse population of older adults: the Multi-Ethnic Study of Atherosclerosis and Air Pollution (MESA Air).

    Science.gov (United States)

    Spalt, Elizabeth W; Curl, Cynthia L; Allen, Ryan W; Cohen, Martin; Adar, Sara D; Stukovsky, Karen H; Avol, Ed; Castro-Diehl, Cecilia; Nunn, Cathy; Mancera-Cuevas, Karen; Kaufman, Joel D

    2016-06-01

    The primary aim of this analysis was to present and describe questionnaire data characterizing time-location patterns of an older, multiethnic population from six American cities. We evaluated the consistency of results from repeated administration of this questionnaire and between this questionnaire and other questionnaires collected from participants of the Multi-Ethnic Study of Atherosclerosis and Air Pollution (MESA Air). Participants reported spending most of their time inside their homes (average: 121 h/week or 72%). More than 50% of the participants reported spending no time in several of the location options, including at home outdoors, at work/volunteer/school locations indoors or outdoors, or in "other" locations outdoors. We observed consistency between self-reported time-location patterns from repeated administration of the time-location questionnaire and compared with other survey instruments. Comparisons with national cohorts demonstrated the differences in time-location patterns in the MESA Air cohort due to differences in demographics, but the data showed similar trends in patterns by age, gender, season, and employment status. This study was the first to explicitly examine the time-location patterns in an older, multiethnic population and the first to add data on Chinese participants. These data can be used to inform future epidemiological research of MESA Air and other studies that include diverse populations.

  9. Study on the friction of κ-carrageenan hydrogels in air and aqueous environments.

    Science.gov (United States)

    Kozbial, Andrew; Li, Lei

    2014-03-01

    Understanding the friction mechanism of polysaccharide hydrogels, which is the key component of human cartilage that has very low friction coefficient, is critical to develop next generation artificial joint replacement materials. In this study, the friction of the polysaccharide κ-carrageenan hydrogel was investigated to elucidate the effect of external load, cross-linking density, velocity, and environment on friction. Our experimental results show that (1) coefficient of friction (COF) decreases with normal load in air and remains constant in water, (2) increasing cross-linking density concurrently increases friction and is proportional to Young's modulus, (3) COF increases with testing velocity in both air and water, and (4) friction is reduced in aqueous environment due to the lubricating effect of water. The underlying frictional mechanism is discussed on the basis of water transport from bulk to surface and a previously proposed "repulsion-adsorption" model. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Controlled-air incineration studies at the Los Alamos Scientific Laboratory

    International Nuclear Information System (INIS)

    Borduin, L.C.; Neuls, A.S.; Thompson, T.K.; Warner, C.L.

    1978-01-01

    An overview of the LASL controlled-air incineration (CAI) program is provided through a description of the process, a summary of component selection and system design criteria, a statement of project status, and discussion of experimental and process improvement study plans. The results of the program will be used to formulate the design criteria and operating parameters for a production model controlled-air transuranic (TRU) waste incineration system and govern the construction and operation of a facility for this purpose. The objective of the LASL CAI project is to develop and demonstrate an effective, safe, and reliable process for volume reduction and chemical stabilization of TRU solid wastes using proven technology whenever possible. The benefits of this process will be realized in reduced handling and storage hazards potentials, lower packaging, transportation, and storage expenses, less storage space requirements, and fewer monitoring needs

  11. A Case Study on Air Combat Decision Using Approximated Dynamic Programming

    Directory of Open Access Journals (Sweden)

    Yaofei Ma

    2014-01-01

    Full Text Available As a continuous state space problem, air combat is difficult to be resolved by traditional dynamic programming (DP with discretized state space. The approximated dynamic programming (ADP approach is studied in this paper to build a high performance decision model for air combat in 1 versus 1 scenario, in which the iterative process for policy improvement is replaced by mass sampling from history trajectories and utility function approximating, leading to high efficiency on policy improvement eventually. A continuous reward function is also constructed to better guide the plane to find its way to “winner” state from any initial situation. According to our experiments, the plane is more offensive when following policy derived from ADP approach other than the baseline Min-Max policy, in which the “time to win” is reduced greatly but the cumulated probability of being killed by enemy is higher. The reason is analyzed in this paper.

  12. Study of noise in offices with window-type room air-conditioners

    International Nuclear Information System (INIS)

    Shaikh, G.H.; Hashmi, R.; Shareef, A.

    2005-01-01

    A Study of Noise has been carried out in 17 private offices, with window-type room air-conditioners, to assess noise levels in these offices. A-Weighted equivalent sound-pressure levels (dB(A) LAeq) and equivalent octave-band sound-pressure levels (dB Leq) were measured in each office, and Preferred Speech Interference Levels (PSIL) evaluated. The results show that the interior noise-levels in these offices vary from 59.6 to 72.2 dB(A) LAeq. which are very high and much above the interior noise limits, recommended for offices by some individual workers. Some ways and means to limit its emission of high level of noise from the air conditioners are also discussed. (author)

  13. An energy and exergy study of a solar thermal air collector

    Directory of Open Access Journals (Sweden)

    Mohseni-Languri Ehsan

    2009-01-01

    Full Text Available A solar flat plate air collector was manufactured in the north of Iran, and connected to a room as the model to study the possibility of using such solar heating systems in the northern parts of Iran. This collector was tested as a solar air heater to see how good it could be for warming up the test room during the winter. The experimental data obtained through accurate measurements were analyzed using second law approach to find the optimum mass flow rate, which leads to the maximum exergy efficiency. It was found that for the test setup at the test location, a mass flow rate of 0.0011 kg/s is the optimum mass flow rate for tested conditions which leads to the highest second law efficiency.

  14. On the problem of low-temperature air adsorption studies by the volume method

    International Nuclear Information System (INIS)

    Gur'yanov, V.V.; Gashin, V.M.; Shcherbakov, V.P.; Misin, M.S.; Sizova, G.P.

    1975-01-01

    The properties of a porous structure and the adsorption of a series of carbon adsorbents at 77 K were studied. It was shown that isotherms may be constructed within the framework of the theory of volume filling only for a degree of filling of theta>20.5. Deviations from theoretical curves are observed with practically no accumulation in the high-vacuum equipment of carbon-adsorbed helium, hydrogen, and neon. Therefore the initial parts of the air-adsorption isotherm at 77 K may not be used for characterizing the adsorption properties and parameters of the porous structure of a microporous adsorbent. The effect of adsorbent microporosity on the adsorption isotherm begins to appear only when the pressure of the poorly sorbed components of the air is less than the total pressure of the nitrogen and oxygen

  15. Study of particulates and heavy elements in air of some Syrian cities

    International Nuclear Information System (INIS)

    Othman, I.; Al-Oudat, M.; Al-Rayes, A. H.; Al- Kharfan, K.

    1999-11-01

    A study of air pollution in different sites of five Syrian cities (Damascus, Aleppo, Tartous, Homs, and Sweda) was carried out. The concentration of total suspended particulate (TSP), particulate less than 10 microns (PM 10) and less than 3 microns (PM 3) were measured using high volume air sampler (HVAS). Heavy element concentration, Pb, Cd, Zn, and Cu were also determined using anodic stripping voltametry. The result showed that TSP, PM 10 and PM 3 were higher than WHO standards in several times. Mean lead concentrations ranged between 0.58 and 2.96 μg/m 3 and 0.56 and 1.53 μg/m 3 in Damascus and Aleppo respectively, while in the other cities these concentrations were less than WHO standards (0.5 - 1 μg/m 3 ). (author)

  16. Studies of Cosmic Ray Composition and Air Shower Structure with the Pierre Auger Observatory

    Energy Technology Data Exchange (ETDEWEB)

    Abraham, : J.; Abreu, P.; Aglietta, M.; Aguirre, C.; Ahn, E.J.; Allard, D.; Allekotte, I.; Allen, J.; Alvarez-Muniz, J.; Ambrosio, M.; Anchordoqui, L.

    2009-06-01

    These are presentations to be presented at the 31st International Cosmic Ray Conference, in Lodz, Poland during July 2009. It consists of the following presentations: (1) Measurement of the average depth of shower maximum and its fluctuations with the Pierre Auger Observatory; (2) Study of the nuclear mass composition of UHECR with the surface detectors of the Pierre Auger Observatory; (3) Comparison of data from the Pierre Auger Observatory with predictions from air shower simulations: testing models of hadronic interactions; (4) A Monte Carlo exploration of methods to determine the UHECR composition with the Pierre Auger Observatory; (5) The delay of the start-time measured with the Pierre Auger Observatory for inclined showers and a comparison of its variance with models; (6) UHE neutrino signatures in the surface detector of the Pierre Auger Observatory; and (7) The electromagnetic component of inclined air showers at the Pierre Auger Observatory.

  17. A study of the physical factors affecting air pollution dispersion in Helwan

    International Nuclear Information System (INIS)

    Megahed, A.A.

    1992-01-01

    Air pollution is considered as one of the most important environmental problems facing the humanity. Cement industry, usually, is responsible for building high levels of pollutants. The present research focused on the study of air pollution control of cement industry using mathematical modeling. A mathematical dispersion model was developed based on Gaussian distribution where the dispersion parameters increase with increasing atmospheric turbulence. The Gaussian equation takes in consideration the effect of emission rates. stack height, buoyant plume rise, weather and meteorological parameters. The model was tested for different stack heights, wind speeds. And atmospheric stability classes. Maximum ground level concentration of cement pollutants were measured in different locations of Helwan, south Cairo around the cement factories. Analysis of results shows that the ground level of pollutants concentrations are inversely proportional to wind speed and atmospheric stability classes. Stack height also affects the behaviour of deposition of cement particulates. The model results show satisfactory agreement with the measured concentrations. 6 figs

  18. STUDY OF FLOW IN AIR-INTAKE SYSTEM FOR A SINGLE-CYLINDER GO-KART ENGINE

    Directory of Open Access Journals (Sweden)

    S. A. Sulaiman

    2010-06-01

    Full Text Available Intake-air manifolds have a major effect on a vehicle’s engine performance and emission of noise and pollutants. Differences in engine outputs and applications require different designs of intake-air manifolds in order to achieve the best volumetric efficiency and thus the best engine performance. In the present work, the flow characteristics of air flowing in various designs of air-intake manifold of a 200-cc four-stroke Go-Kart engine are studied. The study is done by three dimensional simulations of the flow of air within six designs of air-intake manifold into the combustion chamber by using commercial CFD software, Fluent version 6.2. The simulation results are validated by an experimental study performed using a flow bench. The study reveals that the variations in the geometry of the air-intake system can result in a difference of up to 20% in the mass flow rate of air entering the combustion chamber.

  19. Applicability of the Environmental Relative Moldiness Index for Quantification of Residential Mold Contamination in an Air Pollution Health Effects Study

    Science.gov (United States)

    As part of the Near-Road Exposures and Effects of Urban Air Pollutants Study (NEXUS) investigating the respiratory health impacts of traffic-related air pollutants on asthmatic children in Detroit, Michigan, residential dust samples were collected to quantify mold exposure. Sett...

  20. Urinary uranium and kidney function parameters in professional assistance workers in the Epidemiological Study Air Disaster in Amsterdam (ESADA)

    NARCIS (Netherlands)

    J.A. Bijlsma (Joost); P. Slottje (Pauline); A.C. Huizink (Anja); J.W.R. Twisk (Jos); G.B. van der Voet (Gijsbert); F.A. de Wolff (Frederik); F. Vanhaecke (Frank); L. Moens (Luc); T. Smid (Tjabe)

    2008-01-01

    textabstractBackground. The Epidemiological Study Air Disaster in Amsterdam (ESADA) aimed to assess long-term health effects in professional assistance workers involved in the 1992 air disaster in Amsterdam. As part of ESADA indications of nephrotoxicity due to exposure to uranium from the balance

  1. Urinary uranium and kidney function parameters in professional assistance workers in the Epidemiological Study Air Disaster in Amsterdam (ESADA)

    NARCIS (Netherlands)

    Bijlsma, Joost A.; Slottje, Pauline; Huizink, Anja C.; Twisk, Jos W. R.; van der Voet, Gijsbert B.; de Wolff, Frederik A.; Vanhaecke, Frank; Moens, Luc; Smid, Tjabe

    2008-01-01

    The Epidemiological Study Air Disaster in Amsterdam (ESADA) aimed to assess long-term health effects in professional assistance workers involved in the 1992 air disaster in Amsterdam. As part of ESADA indications of nephrotoxicity due to exposure to uranium from the balance weights of the crashed

  2. Association between mortality and indicators of traffic-related air pollution in the Netherlands: A cohort study

    NARCIS (Netherlands)

    Hoek, G.; Brunekreef, B.; Goldbohm, S.; Fischer, P.; Brandt, P.A. van den

    2002-01-01

    Background: Long-term exposure to particulate matter air pollution has been associated with increased cardiopulmonary mortality in the USA. We aimed to assess the relation between traffic-related air pollution and mortality in participants of the Netherlands Cohort study on Diet and Cancer (NLCS),

  3. Experimental study on two-stage air supply downdraft gasifier and dual fuel engine system

    Energy Technology Data Exchange (ETDEWEB)

    Nhuchhen, Daya Ram; Salam, P.A. [Asian Institute of Technology, Energy Field of Study, School of Environment Resource and Development, P. O. Box 4, Klong Luang, Pathumthani (Thailand)

    2012-06-15

    Biomass is a widely used renewable energy resource with net balanced carbon dioxide absorptions and emissions. An inefficient use of solid biomass in combustion process emits more gaseous pollutants, increasing the pollution level. Biomass gasification is one of the techniques to support efficient use of biomass. Multistage gasification is a method of gasification to improve quality of the producer gas in which two separate reactors are designed for separating gasification reactions. This study presents experimental results of gasification using Eucalyptus wood in a single long cylindrical reactor with two air supply ports, i.e., primary and secondary. The effect of different air supply rates on the heating values of the producer gas was studied. Optimum primary and secondary air supply rate of 100 and 80 l/min at equivalence ratio of 0.38 was observed with producer gas lower heating value of 4.72 MJ Nm{sup -3}. The performance of a diesel engine in the dual fuel mode was also evaluated. The overall gasifier engine system efficiency was 13.86 % at an electrical load of 10.54 kW{sub e} with specific energy consumption of 16.22 MJ kWh{sup -1}. The heat recovery system was designed and tested to recover heat from producer gas in the form of hot water. (orig.)

  4. Air particulate pollution studies in Asian countries using nuclear analytical techniques

    International Nuclear Information System (INIS)

    Hien, P.D.

    1998-01-01

    Air particulate pollution is regarded as critical in Asian cities. The levels of suspended particulate matter in major Asian cities far exceed the WHO's guideline. Nuclear analytical techniques have been widely used in the studies of air particulate pollution to provide aerosol elemental compositions for the purpose of deriving the structure of emission sources. This paper presents some preliminary observations and findings based on publications in scientific literatures. Data on PM-10 levels and socio-economic indicators are used for searching a relationship between air quality and the level of development across Asia. An inverse linear relationship between PM-10 levels and logarithm of per capita GDP appears to exist, although there are large fluctuations of data caused by the very different climatic and geographical conditions of cities studied. Soil dust is generally a major, or even predominant aerosol source in Asian cities. Other common sources include vehicular emissions, coal and oil combustion, burning of refuse (in open) and biomass (including forest fires). The relevance and the trends of these sources in Asian context are discussed. Multivariate receptor modelling techniques applied in source characterization are illustrated through the cases of Lahore and Hochiminh City. Although having limitations in dealing with mixing and overlapping sources, receptor modelling based on principal component factor analysis has been proven to be uncomplicated and sufficiently reliable for characterising aerosol sources in urban areas. (author)

  5. A statistical study of the macroepidemiology of air pollution and total mortality

    Energy Technology Data Exchange (ETDEWEB)

    Lipfert, F.W.; Malone, R.G.; Daum, M.L.; Mendell, N.R.; Yang, Chin-Chun

    1988-04-01

    A statistical analysis of spatial patterns of 1980 US urban total mortality (all causes) was performed, evaluating demographic, socioeconomic and air pollution factors as predictors. Specific mortality predictors included cigarette smoking, drinking water hardness, heating fuel use, and 1978-1982 annual concentrations of the following air pollutants: ozone, carbon monoxide, sulfate aerosol, particulate concentrations of lead, iron, cadmium, manganese, vanadium, as well as total and fine particle mass concentrations from the inhalable particulate network (dichotomous samplers). In addition, estimates of sulfur dioxide, oxides of nitrogen, and sulfate aerosol were made for each city using the ASTRAP long-range transport diffusion model, and entered into the analysis as independent variables. Because the number of cities with valid air quality and water hardness data varied considerably by pollutant, it was necessary to consider several different data sets, ranging from 48 to 952 cities. The relatively strong associations (ca. 5--10%) shown for 1980 pollution with 1980 total mortality are generally not confirmed by independent studies, for example, in Europe. In addition, the US studies did not find those pollutants with known adverse health effects at the concentrations in question (such as ozone or CO) to be associated with mortality. The question of causality vs. circumstantial association must therefore be regarded as still unresolved. 59 refs., 20 figs., 40 tabs.

  6. Microprocessor-based data acquisition system for extensive air shower studies

    International Nuclear Information System (INIS)

    Mazumdar, G.K.D.; Kalita, P.M.; Bordoloi, T.C.; Pathak, K.M.

    1989-01-01

    Studies on electromagnetic radiation from large extensive air showers (Esub(p) ≥> 10 16 eV) have been of recent importance in the investigation of properties of EAS in problems involving mass composition, arrival time, radio emission. Cerenkov radiation etc. Such studies need fast electronic circuitry preferably for digitisation. A microprocessor based data acquisition system having scintillation counters, PA, MA, Pd, S/H and control unit has been developed and is being used in the EAS studies at Gauhati University Cosmic Ray Research Laboratory. Description of the different units along with their functioning and method of standardisation is presented in this paper. (author). 3 figs

  7. Geriatric study in Europe on health effects of air quality in nursing homes (GERIE study) profile: objectives, study protocol and descriptive data.

    Science.gov (United States)

    Annesi-Maesano, Isabella; Norback, Dan; Zielinski, Jan; Bernard, Alfred; Gratziou, Cristina; Sigsgaard, Torben; Sestini, Piersante; Viegi, Giovanni

    2013-11-21

    Indoor air pollution (IAP) constitutes a major global public health problem requiring increasing efforts in research and policymaking that may have special significance for elderly that are likely to spend most of their day indoors and appear to be particularly susceptible to adverse effects of chemical pollutants and bio-contaminants. Yet, evidence existing on the effects of IAP in elderly is scanty. The Geriatric study in Europe on health effects of air quality in nursing homes (GERIE) study aimed to assess health effects of major indoor air pollutants and thermal conditions in elderly (> 70 years) living stably in nursing homes (NH) across Europe. Respiratory effects were particularly considered as airways and lung constitute the first target of air pollutants. We describe here the rationale and the methods of the GERIE Study. 8 nursing homes were randomly selected in 7 European countries. Twenty individuals were randomly selected in each nursing home. Major indoor and outdoor air chemical pollutants (PM10, PM2.5, PM0.1, formaldehyde, NO2; O3, VOC, CO2) and bio-contaminants (moulds, allergens) were assessed objectively with standardized procedures. Major health status indicators were assessed through a standardized questionnaire, non-invasive clinical tests and blood and urine biomarkers as well as saliva for ADN. The GERIE study has given the opportunity to publish two reviews on respiratory health effects of indoor and outdoor air pollution in elderly. In addition it has provided the inventory of air quality and thermal conditions in 50 nursing homes across Europe and data on respiratory health status in 600 elderly aged 82 years in mean. Major future results will include the relationships between NH environment and health in elderly. The main long-term purpose of the GERIE study is to improve the health of elderly who permanently reside in nursing homes or of those who are exposed to indoor air pollution because of reduced mobility.

  8. Studies of Ink Trapping III Direct Detection of Small Air Bubbles in Ink Layer

    Directory of Open Access Journals (Sweden)

    Ikuo Naito

    2006-12-01

    Full Text Available Ink trappings were studied by using polyethylene terephthalate (PET film with black inks for offset proofing and synthetic paper. By observing printed matter from reverse side through the PET film, we detected many air bubbles in the ink layer and between the ink layer and the PET film. They are classified roughly to two groups, small number of large ones (φ = 2 - 5 μm and many small ones (φ = 0.5 - 1.0 μm. The former ones were fixed air bubbles during the trapping. The latter ones decreased according to increase the amount of ink trapped (y. Because number of the air bubbles (Nair bubble increased with increasing the ink distribution time, they seemed to be yielded by suspension of air into the ink layer during ink distribution. By observing printed surface, we also detected many ink peaks (immediately after the trapping and pinholes (at 24 h. The numbers of the ink peaks and pinholes (Nink peak and Npinhole, respectively decreased also with increasing the y value and increased with increasing the ink distribution time. We studied effects of nip width on these values (distribution time = 2 min.; nip width = 2, 3 and 4 mm. The Nair bubble value decreased with increasing nip width contrary to increase the Nink peak and Npinhole values. The effects can be represented by differences in the values of 2 and 4 mm nip widths. At y = 2 gm-2, the difference in the Nair bubble value is about one third (synthetic paper ink or a half (offset proofing ink of the difference in the Nink peak values.

  9. Cyclist route choice, traffic-related air pollution, and lung function: a scripted exposure study.

    Science.gov (United States)

    Jarjour, Sarah; Jerrett, Michael; Westerdahl, Dane; de Nazelle, Audrey; Hanning, Cooper; Daly, Laura; Lipsitt, Jonah; Balmes, John

    2013-02-07

    A travel mode shift to active transportation such as bicycling would help reduce traffic volume and related air pollution emissions as well as promote increased physical activity level. Cyclists, however, are at risk for exposure to vehicle-related air pollutants due to their proximity to vehicle traffic and elevated respiratory rates. To promote safe bicycle commuting, the City of Berkeley, California, has designated a network of residential streets as "Bicycle Boulevards." We hypothesized that cyclist exposure to air pollution would be lower on these Bicycle Boulevards when compared to busier roads and this elevated exposure may result in reduced lung function. We recruited 15 healthy adults to cycle on two routes - a low-traffic Bicycle Boulevard route and a high-traffic route. Each participant cycled on the low-traffic route once and the high-traffic route once. We mounted pollutant monitors and a global positioning system (GPS) on the bicycles. The monitors were all synced to GPS time so pollutant measurements could be spatially plotted. We measured lung function using spirometry before and after each bike ride. We found that fine and ultrafine particulate matter, carbon monoxide, and black carbon were all elevated on the high-traffic route compared to the low-traffic route. There were no corresponding changes in the lung function of healthy non-asthmatic study subjects. We also found that wind-speed affected pollution concentrations. These results suggest that by selecting low-traffic Bicycle Boulevards instead of heavily trafficked roads, cyclists can reduce their exposure to vehicle-related air pollution. The lung function results indicate that elevated pollutant exposure may not have acute negative effects on healthy cyclists, but further research is necessary to determine long-term effects on a more diverse population. This study and broader field of research have the potential to encourage policy-makers and city planners to expand infrastructure to

  10. Experimental study of cooling BIPV modules by forced convection in the air channel

    International Nuclear Information System (INIS)

    Kaiser, A.S.; Zamora, B.; Mazón, R.; García, J.R.; Vera, F.

    2014-01-01

    Highlights: • An experimental setup for studying the effects of forced convection on cell temperature. • The induced velocity within the forced convection channel significantly affects the PV cooling. • Correlations for the Ross coefficient, module temperature, efficiency, and power output. • Prediction of the thermal behavior of the PV module in BIPV configurations. - Abstract: The efficiency of photovoltaic systems depends mainly on the cell temperature. Frequently, the PV collectors are installed on the top of the building. One cost effective method to regulate the temperature of rooftop integrated photovoltaic panels is to provide an open air channel beneath the panel. The cell temperature of these PV modules is very much influenced by the capability of ventilating this channel. The ventilation may be modified by different factors such as the wind velocity, the air gap size, and the forced convection induced by a fan or by a conventional air conditioning system. This paper describes an experimental setup to study the influence of the air gap size and the forced ventilation on the cell temperature (and consequently on the electrical efficiency of the PV module) of a BIPV configuration, for different values of the incident solar radiation, ambient temperatures, and aspect ratios, as well as for several forced ventilation conditions. Semi empirical correlations for the Ross coefficient, module temperature, electrical efficiency, and power output are proposed, showing a good agreement with respect to experimental measurements. A critical channel aspect ratio close to 0.11 can be considered to minimize overheating of PV devices. For a duct velocity V v = 6 m/s, a power output increase of 19% is observed over the natural ventilation case (V v = 0.5 m/s)

  11. A parametric study of microjet assisted methane/air turbulent flames

    International Nuclear Information System (INIS)

    Chouaieb, Sirine; Kriaa, Wassim; Mhiri, Hatem; Bournot, Philippe

    2017-01-01

    Highlights: • Microjet assisted methane/air turbulent flames are numerically investigated. • A parametric study concerning the microjet velocity and diameter is carried out. • Previous validation of temperature, mixture fraction and soot is enhanced. • Mixing and soot emission are controlled for higher velocities and lower diameters. • Soot production is reduced by 94% for a microjet velocity equal to 1 m/s. - Abstract: A parametric study of microjet assisted methane/air turbulent flames characteristics is numerically investigated. The Presumed Probability Density Function model and the Discrete Ordinates model are respectively considered for combustion and radiation modeling. The k-epsilon Standard model with Pope Correction is adopted as a turbulence closure model. The two step Tesner model is used to quantify the soot particle production in the flame configuration. Comparison with our previous work using the k-epsilon Realizable model shows that the k-epsilon Standard model with Pope Correction ensures better predictions. The microjet velocity and diameter effects on thermal field, mixing process and soot emission are then discussed. Numerical findings show that the microjet can be used as an efficient tool controlling methane/air turbulent flames. On the one hand, it is shown that the microjet creates an inner flame in the vicinity of the central nozzle exit but does not globally alter the methane/air flame shape. On the other hand, mixing process can be enhanced for high microjet Reynolds number either by increasing the microjet velocity or by decreasing its nozzle diameter for a constant microjet mass flow rate. Soot production can be consequently reduced for low microjet diameter and high velocity values.

  12. Exposure to Outdoor Air Pollution and Chronic Bronchitis in Adults: A Case-Control Study

    Directory of Open Access Journals (Sweden)

    P Salameh

    2012-08-01

    Full Text Available Background: Although Lebanon is a highly polluted country, so far no study has specifically been designed to assess the association between outdoor air pollution and chronic bronchitis in this country. Objective: To assess the association between exposure to outdoor air pollution and chronic bronchitis in Lebanon. Methods: A pilot case-control study was conducted in two tertiary care hospitals. Cases consisted of patients diagnosed with chronic bronchitis by a pulmonologist and those epidemiologically confirmed. Controls included individuals free of any respiratory signs or symptoms. After obtaining informed consent, a standardized questionnaire was administered. Results: Bivariate, stratified (over smoking status and gender and multivariate analyses revealed that passive smoking at home (ORa: 2.56, 95% CI: 1.73–3.80 and at work (ORa: 1.89, 95% CI: 1.13–3.17; older age (ORa: 1.75, 95% CI: 1.55–2.39; lower education (ORa: 1.44, 95% CI: 1.21–1.72; living close to a busy road (ORa: 1.95, 95% CI: 1.31– 2.89 and to a local power plant (ORa: 1.62, 95% CI: 1.07–2.45; and heating home by hot air conditioning (ORa: 1.85, 95% CI: 1.00–3.43 were moderately associated with chronic bronchitis; an inverse association was found with heating home electrically (ORa: 0.58, 95% CI: 0.39–0.85. A positive dose-effect relationship was observed in those living close to a busy road and to a local diesel exhaust source. Conclusion: Chronic bronchitis is associated with outdoor air pollution.

  13. How much, how long, what, and where: air pollution exposure assessment for epidemiologic studies of respiratory disease.

    Science.gov (United States)

    Brauer, Michael

    2010-05-01

    Epidemiology has played an important role in the understanding of air pollution as a risk factor for respiratory disease and in the evidence base for air quality standards. With the widespread availability of genetic information and increasingly sophisticated measurements of molecular markers of adverse effects, there is a need for more specific and precise assessment of exposure to maximize the potential information to be derived from epidemiologic studies. Here advances in air pollution exposure assessment and their applications to studies of respiratory disease are reviewed, with a focus on recent studies of traffic-related air pollution and asthma. Although continuous measurements of personal exposures for all study subjects for a complete study period might be considered the desired "gold standard" for exposure, this is rarely, if ever, achieved due to feasibility constraints. Given this, exposure is typically estimated using models. Recent applications of geospatial (e.g., land use regression) models to studies of respiratory disease have made possible new study designs focused on spatial variability in exposure within urban areas and have provided new insights into the potential role of traffic-related air pollution (TRAP) as a risk factor for the development of childhood asthma. Substantial uncertainty remains, however, regarding what agent(s) within TRAP might be responsible for the observed associations. Future research will require increasing the specificity of exposure assessment to identify the potential roles of individual air pollution components, to elucidate potential mechanisms, and to facilitate studies of mixtures and gene-air pollution interactions.

  14. Exposure to air pollution and self-reported effects on Chinese students: A case study of 13 megacities

    Science.gov (United States)

    2018-01-01

    Air pollution causes severe physical and psychological health complications. Considering China’s continuously-deteriorating air quality, this study aimed to assess the self-reported effects of air pollution on the behavior and physical health of the students of 13 densely populated cities, and their awareness, practices, and perception of air pollution and its associated public health risks. A detailed, closed-ended questionnaire was administered to 2100 students from 54 universities and schools across China. The questionnaire, which had 24 questions, was categorized into four sections. The first two sections were focused on air pollution-associated behavior and psychology, and physical effects; while the final two sections focused on the subjects’ awareness and perceptions, and practices and concerns about air pollution. The respondents reported that long-term exposure to air pollution had significantly affected their psychology and behavior, as well as their physical health. The respondents were aware of the different adverse impacts of air pollution (respiratory infections, allergies, and cardiovascular problems), and hence had adopted different preventive measures, such as the use of respiratory masks and glasses or goggles, regularly drinking water, and consuming rich foods. It was concluded that air pollution and haze had negative physical and psychological effects on the respondents, which led to severe changes in behavior. Proper management, future planning, and implementing strict environmental laws are suggested before this problem worsens and becomes life-threatening. PMID:29547657

  15. Exposure to air pollution and self-reported effects on Chinese students: A case study of 13 megacities.

    Science.gov (United States)

    Rajper, Sohail Ahmed; Ullah, Sana; Li, Zhongqiu

    2018-01-01

    Air pollution causes severe physical and psychological health complications. Considering China's continuously-deteriorating air quality, this study aimed to assess the self-reported effects of air pollution on the behavior and physical health of the students of 13 densely populated cities, and their awareness, practices, and perception of air pollution and its associated public health risks. A detailed, closed-ended questionnaire was administered to 2100 students from 54 universities and schools across China. The questionnaire, which had 24 questions, was categorized into four sections. The first two sections were focused on air pollution-associated behavior and psychology, and physical effects; while the final two sections focused on the subjects' awareness and perceptions, and practices and concerns about air pollution. The respondents reported that long-term exposure to air pollution had significantly affected their psychology and behavior, as well as their physical health. The respondents were aware of the different adverse impacts of air pollution (respiratory infections, allergies, and cardiovascular problems), and hence had adopted different preventive measures, such as the use of respiratory masks and glasses or goggles, regularly drinking water, and consuming rich foods. It was concluded that air pollution and haze had negative physical and psychological effects on the respondents, which led to severe changes in behavior. Proper management, future planning, and implementing strict environmental laws are suggested before this problem worsens and becomes life-threatening.

  16. Experimental investigation of the effect of air velocity on a unit cooler under frosting condition: a case study

    Science.gov (United States)

    Bayrak, Ergin; Çağlayan, Akın; Konukman, Alp Er S.

    2017-10-01

    Finned tube evaporators are used in a wide range of applications such as commercial and industrial cold/freezed storage rooms with high traffic loading under frosting conditions. In this case study, an evaporator with an integrated fan was manufactured and tested under frosting conditions by only changing the air flow rate in an ambient balanced type test laboratory compared to testing in a wind tunnel with a more uniform flow distribution in order to detect the effect of air flow rate on frosting. During the test, operation was performed separately based on three different air flow rates. The parameters concerning test operation such as the changes of air temperature, air relative humidity, surface temperature, air-side pressure drop and refrigerant side capacity etc. were followed in detail for each air flow rate. At the same time, digital images were captured in front of the evaporator; thus, frost thicknesses and blockage ratios at the course of fan stall were determined by using an image-processing technique. Consequently, the test and visual results showed that the trendline of air-side pressure drop increased slowly at the first stage of test operations, then increased linearly up to a top point and then the linearity was disrupted instantly. This point speculated the beginning of defrost operation for each case. In addition, despite detecting a velocity that needs to be avoided, a test applied at minimum air velocity is superior to providing minimum capacity in terms of loss of capacity during test operations.

  17. Part 5. Public health and air pollution in Asia (PAPA): a combined analysis of four studies of air pollution and mortality.

    Science.gov (United States)

    Wong, C M; Vichit-Vadakan, N; Vajanapoom, N; Ostro, B; Thach, T Q; Chau, P Y K; Chan, E K P; Chung, R Y N; Ou, C Q; Yang, L; Peiris, J S M; Thomas, G N; Lam, T H; Wong, T W; Hedley, A J; Kan, H; Chen, B; Zhao, N; London, S J; Song, G; Chen, G; Zhang, Y; Jiang, L; Qian, Z; He, Q; Lin, H M; Kong, L; Zhou, D; Liang, S; Zhu, Z; Liao, D; Liu, W; Bentley, C M; Dan, J; Wang, B; Yang, N; Xu, S; Gong, J; Wei, H; Sun, H; Qin, Z

    2010-11-01

    In recent years, Asia has experienced rapid economic growth and a deteriorating environment caused by the increasing use of fossil fuels. Although the deleterious effects of air pollution from fossil-fuel combustion have been demonstrated in many Western nations, few comparable studies have been conducted in Asia. Time-series studies of daily mortality in Asian cities can contribute important new information to the existing body of knowledge about air pollution and health. Not only can these studies verify important health effects of air pollution in local regions in Asia, they can also help determine the relevance of existing air pollution studies to mortality and morbidity for policymaking and environmental controls. In addition, the studies can help identify factors that might modify associations between air pollution and health effects in various populations and environmental conditions. Collaborative multicity studies in Asia-especially when designed, conducted, and analyzed using a common protocol-will provide more robust air pollution effect estimates for the region as well as relevant, supportable estimates of local adverse health effects needed by environmental and public-health policymakers. The Public Health and Air Pollution in Asia (PAPA*) project, sponsored by the Health Effects Institute, consisted of four studies designed to assess the effects of air pollution on mortality in four large Asian cities, namely Bangkok, in Thailand, and Hong Kong, Shanghai, and Wuhan, in China. In the PAPA project, a Common Protocol was developed based on methods developed and tested in NMMAPS, APHEA, and time-series studies in the literature to help ensure that the four studies could be compared with each other and with previous studies by following an established protocol. The Common Protocol (found at the end of this volume) is a set of prescriptive instructions developed for the studies and used by the investigators in each city. It is flexible enough to allow for

  18. Experimental study on axisymmetric air intake for the supersonic transport; choonsokukiyo jikutaishogata air intake no jikken kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    Sato, T. [Institute of the Space and Astronautical Science,Tokyo (Japan); Takagi, I. [Kawasaki Heavy Industries, Ltd., Kobe (Japan); Kojima, T.; Kobayashi, H. [The University of Tokyo, Tokyo (Japan)

    1998-12-05

    Mixed-compression type axisymmetric air intakes for ATREX engine have been tested in the supersonic wind tunnel from Mach 0.5 to 4 since 1993. The throat area of the intake can be variable with a translating center spike to accomplish starting and off-design operation since the ATREX intake must work well over the wide flight Mach number up to 6. Here are presented effects of the intake design Mach number, the air bleed from a center spike and/or a cowl around the throat, an angle of attack and blunt nose of the spike on the intake performance characteristics, that is total pressure recovery and mass capture ratio. It is found that bleeding from the center spike and the cowl influences mainly on total pressure recovery and mass capture ratio respectively. The advantage of rounding properly off the spike nose is confirmed. Small center spike cone angle and/or blunt nose is sensitive to the angle of attack. (author)

  19. IMPACT OF HEATING AND AIR CONDITIONING SYSTEM OPERATION AND LEAKAGE ON VENTILATION AND INTERCOMPARTMENT TRANSPORT: STUDIES IN UNOCCUPIED AND OCCUPIED TENNESSEE VALLEY HOMES

    Science.gov (United States)

    Forced-air heating and air conditioning (HAC) systems caused an average and maximum increase in air infiltration rates of 1.8- and 4.3-fold, respectively, during brief whole-house studies of tracer gas decay In 39 occupied houses. An average Increase in air infiltration rate of 0...

  20. Outdoor air pollution, exhaled 8-isoprostane and current asthma in adults: the EGEA study.

    Science.gov (United States)

    Havet, Anaïs; Zerimech, Farid; Sanchez, Margaux; Siroux, Valérie; Le Moual, Nicole; Brunekreef, Bert; Stempfelet, Morgane; Künzli, Nino; Jacquemin, Bénédicte; Matran, Régis; Nadif, Rachel

    2018-04-01

    Associations between outdoor air pollution and asthma in adults are still scarce, and the underlying biological mechanisms are poorly understood. Our aim was to study the associations between 1) long-term exposure to outdoor air pollution and current asthma, 2) exhaled 8-isoprostane (8-iso; a biomarker related to oxidative stress) and current asthma, and 3) outdoor air pollution and exhaled 8-iso.Cross-sectional analyses were conducted in 608 adults (39% with current asthma) from the first follow-up of the French case-control and family study on asthma (EGEA; the Epidemiological study of the Genetic and Environmental factors of Asthma). Data on nitrogen dioxide, nitrogen oxides, particulate matter with a diameter ≤10 and ≤2.5 µm (PM 10 and PM 2.5 ), road traffic, and ozone (O 3 ) were from ESCAPE (European Study of Cohorts for Air Pollution Effects) and IFEN (French Institute for the Environment) assessments. Models took account of city and familial dependence.The risk of current asthma increased with traffic intensity (adjusted (a)OR 1.09 (95% CI 1.00-1.18) per 5000 vehicles per day), with O 3 exposure (aOR 2.04 (95% CI 1.27-3.29) per 10 µg·m -3 ) and with exhaled 8-iso concentration (aOR 1.50 (95% CI 1.06-2.12) per 1 pg·mL -1 ). Among participants without asthma, exhaled 8-iso concentration increased with PM 2.5 exposure (adjusted (a)β 0.23 (95% CI 0.005-0.46) per 5 µg·m -3 ), and decreased with O 3 and O 3-summer exposures (aβ -0.20 (95% CI -0.39- -0.01) and aβ -0.52 (95% CI -0.77- -0.26) per 10 µg·m -3 , respectively).Our results add new insights into a potential role of oxidative stress in the associations between outdoor air pollution and asthma in adults. Copyright ©ERS 2018.

  1. Study on the impact of industrial flue gases on the PCDD/Fs congener profile in ambient air.

    Science.gov (United States)

    Węgiel, Małgorzata; Chrząszcz, Ryszard; Maślanka, Anna; Grochowalski, Adam

    2014-11-01

    The aim of this study was to examine the impact of emissions from combustion processes from sinter, medical, waste and sewage waste incineration plants on the PCDD and PCDF congener profile in ambient air in Krakow (city in Poland). The subject matter of the study were air samples from the outskirts and the city center. It was found that in flue gases from industrial sources and in ambient air the share of PCDF congeners in relation to the total content of PCDD/Fs was higher than the share of PCDDs. However, in air samples collected in the city center, this relationship was reversed. The PCDD congener profiles in flue gases and in air samples are comparable. However, in the samples from the city centre, the share of OCDD is significantly higher and amounts to about 80%. The PCDF congener shares show higher spatial diversity, although in all the analyzed air samples, ODCF and 1,2,3,4,6,7,8 HpCDF dominated. Analyzing the share of congeners in regard to the sum of PCDDs/Fs a mutual resemblance of air from the suburbs, exhaust gases from the sinter ore and sewage sludge incinerator plant was observed. The study showed a similarity between the profile of congeners in air from the city centre and exhaust gases from the medical waste incinerator. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Effect of Using an Indoor Air Quality Sensor on Perceptions of and Behaviors Toward Air Pollution (Pittsburgh Empowerment Library Study): Online Survey and Interviews.

    Science.gov (United States)

    Wong-Parodi, Gabrielle; Dias, M Beatrice; Taylor, Michael

    2018-03-08

    Air quality affects us all and is a rapidly growing concern in the 21st century. We spend the majority of our lives indoors and can be exposed to a number of pollutants smaller than 2.5 microns (particulate matter, PM 2.5 ) resulting in detrimental health effects. Indoor air quality sensors have the potential to provide people with the information they need to understand their risk and take steps to reduce their exposure. One such sensor is the Speck sensor developed at the Community Robotics, Education and Technology Empowerment Lab at Carnegie Mellon University. This sensor provides users with continuous real-time and historical PM 2.5 information, a Web-based platform where people can track their PM 2.5 levels over time and learn about ways to reduce their exposure, and a venue (blog post) for the user community to exchange information. Little is known about how the use of such monitors affects people's knowledge, attitudes, and behaviors with respect to indoor air pollution. The aim of this study was to assess whether using the sensor changes what people know and do about indoor air pollution. We conducted 2 studies. In the first study, we recruited 276 Pittsburgh residents online and through local branches of the Carnegie Library of Pittsburgh, where the Speck sensor was made available by the researchers in the library catalog. Participants completed a 10- to 15-min survey on air pollution knowledge (its health impact, sources, and mitigation options), perceptions of indoor air quality, confidence in mitigation, current behaviors toward air quality, and personal empowerment and creativity in the spring and summer of 2016. In our second study, we surveyed 26 Pittsburgh residents in summer 2016 who checked out the Speck sensor for 3 weeks on the same measures assessed in the first study, with additional questions about the perception and use of the sensor. Follow-up interviews were conducted with a subset of those who used the Speck sensor. A series of paired t

  3. Study of air and steam leak rate through damaged concrete wall

    International Nuclear Information System (INIS)

    Abdeslam Laghcha; Gerard Debicki; Benoit Masson

    2005-01-01

    Full text of publication follows: The leak rate prediction of air and steam through a cracked concrete wall is an extremely important issue in assessing the safety of nuclear reactor containment building. Furthermore the relation between air leak rate and steam leak rate on the same wall could have some interest for safety prediction. This laboratory study investigates the transfer of fluids through a wall of 1.3 m of thickness, with a focus on two cases: one on a mechanically damaged concrete by compressive stress and another one on a crossing artificial flaw in a construction joint realized in the concrete specimen (cylindrical / section 0.1925 m 2 / length 1.3 m). The both specimens were made of ordinary concrete (compressive strength: 35 MPa). To initiate residual compressive cracks, the specimen (A) was loaded in compression under controlled strains until a level of 90% of the failure strain was reached. To create a crossing artificial flaw in a construction joint, the concrete was set in the mould in two times, the second time, a water saturated sand bed was placed on the surface of the hardened concrete to realize the flaw along a diameter of the specimen (B). The permeability of damaged concrete wall was studied comparatively under two conditions, but without appreciable stresses applied on. The first condition was at ambient temperature, a reference test of permeability, with dry air, gave the characteristics of permeability and the type of flow through the specimen. In this case, the used method consisted to proceed by stages. The imposed pressures on the exposed face were successively 0.1, 0.18, 0.23, 0.28, 0.34 and 0.42 MPa, the other face was at atmospheric pressure. The second condition was an accidental scenario with simultaneous effects of temperature and gas (a mix of air and steam) pressure applied on a face, the other one remaining at atmospheric pressure and temperature. During the test, the lateral face of the cylindrical specimen was thermally

  4. Air Pollution Modeling at Road Sides Using the Operational Street Pollution Model-A Case Study in Hanoi, Vietnam

    DEFF Research Database (Denmark)

    Hung, Ngo Tho; Ketzel, Matthias; Jensen, Steen Solvang

    2010-01-01

    In many metropolitan areas, traffic is the main source of air pollution. The high concentrations of pollutants in streets have the potential to affect human health. Therefore, estimation of air pollution at the street level is required for health impact assessment. This task has been carried out...... in many developed countries by a combination of air quality measurements and modeling. This study focuses on how to apply a dispersion model to cities in the developing world, where model input data and data from air quality monitoring stations are limited or of varying quality. This research uses...... the operational street pollution model (OSPM) developed by the National Environmental Research Institute in Denmark for a case study in Hanoi, the capital of Vietnam. OSPM predictions from five streets were evaluated against air pollution measurements of nitrogen oxides (NO), sulfur dioxide (SO2), carbon monoxide...

  5. Exposure to ambient air pollution and the incidence of dementia: A population-based cohort study.

    Science.gov (United States)

    Chen, Hong; Kwong, Jeffrey C; Copes, Ray; Hystad, Perry; van Donkelaar, Aaron; Tu, Karen; Brook, Jeffrey R; Goldberg, Mark S; Martin, Randall V; Murray, Brian J; Wilton, Andrew S; Kopp, Alexander; Burnett, Richard T

    2017-11-01

    Emerging studies have implicated air pollution in the neurodegenerative processes. Less is known about the influence of air pollution, especially at the relatively low levels, on developing dementia. We conducted a population-based cohort study in Ontario, Canada, where the concentrations of pollutants are among the lowest in the world, to assess whether air pollution exposure is associated with incident dementia. The study population comprised all Ontario residents who, on 1 April 2001, were 55-85years old, Canadian-born, and free of physician-diagnosed dementia (~2.1 million individuals). Follow-up extended until 2013. We used population-based health administrative databases with a validated algorithm to ascertain incident diagnosis of dementia as well as prevalent cases. Using satellite observations, land-use regression model, and an optimal interpolation method, we derived long-term average exposure to fine particulate matter (≤2.5μm in diameter) (PM 2.5 ), nitrogen dioxide (NO 2 ), and ozone (O 3 ), respectively at the subjects' historical residences based on a population-based registry. We used multilevel spatial random-effects Cox proportional hazards models, adjusting for individual and contextual factors, such as diabetes, brain injury, and neighborhood income. We conducted various sensitivity analyses, such as lagging exposure up to 10years and considering a negative control outcome for which no (or weaker) association with air pollution is expected. We identified 257,816 incident cases of dementia in 2001-2013. We found a positive association between PM 2.5 and dementia incidence, with a hazard ratio (HR) of 1.04 (95% confidence interval (CI): 1.03-1.05) for every interquartile-range increase in exposure to PM 2.5 . Similarly, NO 2 was associated with increased incidence of dementia (HR=1.10; 95% CI: 1.08-1.12). No association was found for O 3 . These associations were robust to all sensitivity analyses examined. These estimates translate to 6.1% of

  6. Studies of lead pollution in the air of Shanghai by multiple techniques

    International Nuclear Information System (INIS)

    Tan, M.G.; Zhang, G.L.; Li, X.L.; Zhang, Y.X.; Yue, W.S.; Chen, J.M.; Wang, Y.S.; Li, A.G.; Li, Y.; Zhang, Y.M.; Shan, Z.C.

    2005-01-01

    Lead pollution in atmosphere has been one of the worrisome environmental problems since the tetraethyl lead was used as an antiknock agent in combustion engines. The presence of lead in urban air, even at low doses, may cause neurological impairments of fetuses and young children. Studies also show that lead may be a factor in high blood pressure and subsequent heart disease. Atmospheric lead has various origins, such as gasoline, industrial emissions and coal burning etc. The present work reports the lead levels in air particulate matter samples of PM 10 collected in recent years to evaluate the effect of the use of unleaded gasoline in Shanghai since 1997. The chemical species of lead in PM 10 and their origins were also studied. To our knowledge it is a first time to give an estimation of lead contribution to air in a city from different emission sources quantitatively. Proton-induced X-ray emission analysis (PIXE), proton microprobe (μ-PIXE), inductively coupled plasma-mass spectrometry (ICP-MS) and X-ray absorption fine structure (XAFS) techniques were used to study the concentration, the chemical species and the source assignment of Pb in the atmospheric aerosol particles of PM 10 . Average values of 369±74. ng/m 3 and 237±45 ng/m 3 of Pb concentration were obtained from the 19 monitor sites in Shanghai in the winter of 2002 and 2003, respectively. Comparing with the earlier data of 466 ng/m 3 in 1997 and 515 ng/m 3 in 2001, it can be observed that the yearly mean lead levels in PM 10 decline significantly. However, it is also found that rather high levels of lead still remain. in the air of Shanghai after the use of unleaded gasoline. The results of XAFS showed that PbCl 2 , PbSO 4 and PbO were probably the main chemical forms of Pb in atmospheric particulate matter. Based on the lead isotope ratios technique and chemical mass balance analysis, the calculation showed that the main emission sources of Pb in the atmosphere of Shanghai were coal combustors

  7. Experimental study of a novel capacity control algorithm for a multi-evaporator air conditioning system

    International Nuclear Information System (INIS)

    Xu Xiangguo; Pan Yan; Deng Shiming; Xia Liang; Chan Mingyin

    2013-01-01

    The use of a multi-evaporator air conditioning (MEAC) system is advantageous in terms of installation convenience, high design flexibility, being easy to maintain and commission, better indoor thermal comfort control and higher energy efficiency. While MEAC units worth billions of dollars are sold worldwide, the detailed accounts on compressor capacity control and refrigeration flow distribution amongst evaporators remain unavailable in public domain, mainly due to commercial confidentiality. Limited control algorithms for MEAC systems have been developed based on system simulation, and no experimental-based capacity controller developments and their controllability tests may be identified in open literature. In the study reported in this paper, a novel capacity control algorithm, which imitated On–Off control of a single evaporator air conditioning (A/C) system in each indoor unit of a MEAC system by using variable speed compressor and electronic expansion valves (EEVs), was developed. Controllability tests under various settings for experimentally validating the novel capacity control algorithm were carried out and the control algorithm was further improved based on the experimental results. - Highlights: ► A capacity control algorithm for a multi-evaporator air conditioning system was developed. ► Experimental controllability tests under various settings were carried out. ► The control algorithm was further improved based on the experimental results.

  8. Improved Satellite-based Photosysnthetically Active Radiation (PAR) for Air Quality Studies

    Science.gov (United States)

    Pour Biazar, A.; McNider, R. T.; Cohan, D. S.; White, A.; Zhang, R.; Dornblaser, B.; Doty, K.; Wu, Y.; Estes, M. J.

    2015-12-01

    One of the challenges in understanding the air quality over forested regions has been the uncertainties in estimating the biogenic hydrocarbon emissions. Biogenic volatile organic compounds, BVOCs, play a critical role in atmospheric chemistry, particularly in ozone and particulate matter (PM) formation. In southeastern United States, BVOCs (mostly as isoprene) are the dominant summertime source of reactive hydrocarbon. Despite significant efforts in improving BVOC estimates, the errors in emission inventories remain a concern. Since BVOC emissions are particularly sensitive to the available photosynthetically active radiation (PAR), model errors in PAR result in large errors in emission estimates. Thus, utilization of satellite observations to estimate PAR can help in reducing emission uncertainties. Satellite-based PAR estimates rely on the technique used to derive insolation from satellite visible brightness measurements. In this study we evaluate several insolation products against surface pyranometer observations and offer a bias correction to generate a more accurate PAR product. The improved PAR product is then used in biogenic emission estimates. The improved biogenic emission estimates are compared to the emission inventories over Texas and used in air quality simulation over the period of August-September 2013 (NASA's Discover-AQ field campaign). A series of sensitivity simulations will be performed and evaluated against Discover-AQ observations to test the impact of satellite-derived PAR on air quality simulations.

  9. Experimental study on frosting control of mobile air conditioning system with microchannel evaporator

    International Nuclear Information System (INIS)

    Qu Xiaohua; Shi Junye; Qi Zhaogang; Chen Jiangping

    2011-01-01

    In this paper, a newly developed frost control system is proposed. System bench tests and vehicle test in wind tunnel have been carried out to explore the anti-frosting performance of automotive air conditioning system with microchannel evaporator. The experimental results are compared with the baseline conventional laminated evaporator system. The test results show that the installation position of temperature sensor can dramatically affect the anti-frosting performance. The clutch switching on/off temperature range of the microchannel evaporator is also experimentally studied. The test results show that, with a proper installation position and on/off temperature range, the system COP can be improved, and meanwhile the panel vents' air off temperature can be reduced, and temperature swing can be reduced. - Highlights: → The frost control systems were tested with microchannel and laminated evaporators separately. → The installation position of temperature sensor affects the anti-frosting performance. → Temperature control range affects the anti-frosting performance. → The panel vents' air off temperature and swing can be reduced by proper control parameters. → The system COP can be improved by proper control parameters.

  10. Experimental performance study of a proposed desiccant based air conditioning system.

    Science.gov (United States)

    Bassuoni, M M

    2014-01-01

    An experimental investigation on the performance of a proposed hybrid desiccant based air conditioning system referred as HDBAC is introduced in this paper. HDBAC is mainly consisted of a liquid desiccant dehumidification unit integrated with a vapor compression system (VCS). The VCS unit has a cooling capacity of 5.27 kW and uses 134a as refrigerant. Calcium chloride (CaCl2) solution is used as the working desiccant material. HDBAC system is used to serve low sensible heat factor applications. The effect of different parameters such as, process air flow rate, desiccant solution flow rate, evaporator box and condenser box solution temperatures, strong solution concentration and regeneration temperature on the performance of the system is studied. The performance of the system is evaluated using some parameters such as: the coefficient of performance (COPa), specific moisture removal and energy saving percentage. A remarkable increase of about 54% in the coefficient of performance of the proposed system over VCS with reheat is achieved. A maximum overall energy saving of about 46% is observed which emphasizes the use of the proposed system as an energy efficient air conditioning system.

  11. Measurements of PANs during the New England Air Quality Study 2002

    Science.gov (United States)

    Roberts, J. M.; Marchewka, M.; Bertman, S. B.; Sommariva, R.; Warneke, C.; de Gouw, J.; Kuster, W.; Goldan, P.; Williams, E.; Lerner, B. M.; Murphy, P.; Fehsenfeld, F. C.

    2007-10-01

    Measurements of peroxycarboxylic nitric anhydrides (PANs) were made during the New England Air Quality Study 2002 cruise of the NOAA RV Ronald H Brown. The four compounds observed, PAN, peroxypropionic nitric anhydride (PPN), peroxymethacrylic nitric anhydride (MPAN), and peroxyisobutyric nitric anhydride (PiBN) were compared with results from other continental and Gulf of Maine sites. Systematic changes in PPN/PAN ratio, due to differential thermal decomposition rates, were related quantitatively to air mass aging. At least one early morning period was observed when O3 seemed to have been lost probably due to NO3 and N2O5 chemistry. The highest O3 episode was observed in the combined plume of isoprene sources and anthropogenic volatile organic compounds (VOCs) and NOx sources from the greater Boston area. A simple linear combination model showed that the organic precursors leading to elevated O3 were roughly half from the biogenic and half from anthropogenic VOC regimes. An explicit chemical box model confirmed that the chemistry in the Boston plume is well represented by the simple linear combination model. This degree of biogenic hydrocarbon involvement in the production of photochemical ozone has significant implications for air quality control strategies in this region.

  12. On the study of a sick building: the case of Athens Air Traffic Control Tower

    Energy Technology Data Exchange (ETDEWEB)

    Assimakopoulos, V.D.; Helmis, C.G. [Department of Applied Physics, University of Athens, Athens (Greece)

    2004-07-01

    It is well known that in many cases the responsibility for the formation of the sick-building syndrome lies with the inappropriate envelope design, the misuse of the building by the inhabitants and the combination of indoor-outdoor pollution sources. In the case of Athens Air Traffic Control Tower (ATCT), sick syndrome episodes were reported by the employees. In the present study, recently obtained indoor air quality measurements, during selected meteorological conditions, taken in the ATCT, are presented and discussed. These include concentrations of volatile organic compounds (VOCs), which in many cases were thought responsible for the poor indoor environment. The measurements cover the indoor and outdoor environment of selected building regions, the ventilation systems and the plenum under the floor. The data indicates that there are certain places in the building where the VOCs concentrations were well above outdoor levels, while in others the concentrations were lower. Further analysis of the results showed that the central ventilation system is not sufficient for the building needs and that in some areas, either due to cleaning negligence or to the construction material used, VOCs pollution sources have developed. In order to eliminate these problems and to improve the indoor environment certain actions were taken. Following these interventions a second set of measurements were collected, inside and outside the ATCT building, which indicated a substantial improvement of the indoor air quality. (author)

  13. Urban Heat Island Versus Air Quality - a Numerical Modelling Study for a European City

    Science.gov (United States)

    Fallmann, J.; Forkel, R.; Emeis, S.

    2014-12-01

    In 2050 70% of the global population is expected to live in urban areas. Climate change will render these areas more vulnerable to heat waves, which often are accompanied by severe air pollution problems. The Urban Heat Island (UHI) is a feature that adds to the general temperature increase that is expected. Decreasing the UHI can impact air quality as well, because heat influences atmospheric dynamics and accelerates air chemical processes and often also increases the emission of primary pollutants due to increased demand of energy. The goal of this study is to investigate the effect of, e.g., high reflective surfaces and urban greening on mitigating the UHI and the related impact on air quality. A multi-layer urban canopy model is coupled to the mesoscale model WRF-Chem and the urban area of Stuttgart (South-West Germany) is taken as one example. Different scenario runs are executed for short time periods and are compared to a control run. The results show that the UHI effect can be substantially reduced when changing the albedo of roof surfaces, whereas the effect of urban greening is minor. Both scenarios have in common, that they evoke changes in secondary circulation patterns. The effects of these mitigation strategies on chemical composition of the urban atmosphere are complex, attributed to both chemical and dynamical features. Increasing the reflectivity of roof surfaces in the model results in a net decrease of the surface ozone concentration, because ozone formation is highly correlated to temperature. With regard to primary pollutants, e.g. NO, CO and PM10 concentrations are increased when increasing reflectivity. This effect primarily can be ascribed to a reduction of turbulent motion, convection and a decrease of the boundary layer height, coming along with lower temperatures in the urban canopy layer due to increased reflectivity. The table below shows the effect on grid cell mean concentrations for different chemical species and scenarios.

  14. Design of Parallel Air-Cooled Battery Thermal Management System through Numerical Study

    Directory of Open Access Journals (Sweden)

    Kai Chen

    2017-10-01

    Full Text Available In electric vehicles, the battery pack is one of the most important components that strongly influence the system performance. The battery thermal management system (BTMS is critical to remove the heat generated by the battery pack, which guarantees the appropriate working temperature for the battery pack. Air cooling is one of the most commonly-used solutions among various battery thermal management technologies. In this paper, the cooling performance of the parallel air-cooled BTMS is improved through choosing appropriate system parameters. The flow field and the temperature field of the system are calculated using the computational fluid dynamics method. Typical numerical cases are introduced to study the influences of the operation parameters and the structure parameters on the performance of the BTMS. The operation parameters include the discharge rate of the battery pack, the inlet air temperature and the inlet airflow rate. The structure parameters include the cell spacing and the angles of the divergence plenum and the convergence plenum. The results show that the temperature rise and the temperature difference of the batter pack are not affected by the inlet air flow temperature and are increased as the discharge rate increases. Increasing the inlet airflow rate can reduce the maximum temperature, but meanwhile significantly increase the power consumption for driving the airflow. Adopting smaller cell spacing can reduce the temperature and the temperature difference of the battery pack, but it consumes much more power. Designing the angles of the divergence plenum and the convergence plenum is an effective way to improve the performance of the BTMS without occupying more system volume. An optimization strategy is used to obtain the optimal values of the plenum angles. For the numerical cases with fixed power consumption, the maximum temperature and the maximum temperature difference at the end of the five-current discharge process for

  15. Epidemiological study of air filtration systems for preventing PRRSV infection in large sow herds.

    Science.gov (United States)

    Alonso, Carmen; Murtaugh, Michael P; Dee, Scott A; Davies, Peter R

    2013-10-01

    Porcine reproductive and respiratory syndrome virus (PRRSV) is the most economically significant pathogen in the US swine industry. Aerosol transmission among herds is a major concern in pig dense regions and filtration of incoming air, in combination with standard biosecurity procedures, has been demonstrated to prevent transmission of PRRSV into susceptible herds. To quantify the impact of air filtration on reducing risk of PRRSV outbreaks, we compared the incidence rate of new PRRSV introductions in 20 filtered and 17 non-filtered control sow herds in a swine dense region of North America during a 7 year study period. Events of novel virus introduction were ascertained by phylogenetic analysis of PRRSV ORF5 gene sequences. Putative new viruses were defined as exogenous (introduced) based on ORF5 nucleotide sequence differences compared to previous farm isolates. The influence of sequence difference cut-off values ranging from 2 to 10% on case definition and relative risk were evaluated. Non-filtered farms incurred about 0.5 outbreaks per year, with a seasonal increase in risk in cooler periods. Baseline risk, prior to filtration, in treatment farms was approximately 0.75 per year, approximately 50% higher than in control farms. Air filtration significantly reduced risk of PRRSV introduction events to 0.06-0.22 outbreaks per year, depending on the cut-off values used to classify a virus isolate as new to the herd. Overall, air filtration led to an approximately 80% reduction in risk of introduction of novel PRRSV, indicating that on large sow farms with good biosecurity in swine-dense regions, approximately four-fifths of PRRSV outbreaks may be attributable to aerosol transmission. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. Household air pollution, chronic respiratory disease and pneumonia in Malawian adults: A case-control study.

    Science.gov (United States)

    Jary, Hannah R; Aston, Stephen; Ho, Antonia; Giorgi, Emanuele; Kalata, Newton; Nyirenda, Mulinda; Mallewa, Jane; Peterson, Ingrid; Gordon, Stephen B; Mortimer, Kevin

    2017-01-01

    Background: Four million people die each year from diseases caused by exposure to household air pollution. There is an association between exposure to household air pollution and pneumonia in children (half a million attributable deaths a year); however, whether this is true in adults is unknown. We conducted a case-control study in urban Malawi to examine the association between exposure to household air pollution and pneumonia in adults. Methods: Hospitalized patients with radiologically confirmed pneumonia (cases) and healthy community controls underwent 48 hours of ambulatory and household particulate matter (µg/m 3 ) and carbon monoxide (ppm) exposure monitoring. Multivariate logistic regression, stratified by HIV status, explored associations between these and other potential risk factors with pneumonia. Results: 145 (117 HIV-positive; 28 HIV-negative) cases and 253 (169 HIV-positive; 84 HIV-negative) controls completed follow up. We found no evidence of association between household air pollution exposure and pneumonia in HIV-positive (e.g. ambulatory particulate matter adjusted odds ratio [aOR] 1.00 [95% CI 1.00-1.01, p=0.141]) or HIV-negative (e.g. ambulatory particulate matter aOR 1.00 [95% CI 0.99-1.01, p=0.872]) participants. Chronic respiratory disease was associated with pneumonia in both HIV-positive (aOR 28.07 [95% CI 9.29-84.83, ppollution is associated with pneumonia in Malawian adults. In contrast, chronic respiratory disease was strongly associated with pneumonia.

  17. Air pollution and asthma control in the Epidemiological study on the Genetics and Environment of Asthma

    Science.gov (United States)

    Jacquemin, Bénédicte; Kauffmann, Francine; Pin, Isabelle; Le Moual, Nicole; Bousquet, Jean; Gormand, Frédéric; Just, Jocelyne; Nadif, Rachel; Pison, Christophe; Vervloet, Daniel; Künzli, Nino; Siroux, Valérie

    2012-01-01

    Background The associations between exposure to air pollution and asthma control are not well known. The objective is to assess the association between long term exposure to NO2, O3 and PM10 and asthma control in the EGEA2 study (2003–2007). Methods Modeled outdoor NO2, O3 and PM10 estimates were linked to each residential address using the 4-km grid air pollutant surface developed by the French Institute of Environment for 2004. Asthma control was assessed in 481 subjects with current asthma using a multidimensional approach following the 2006–2009 GINA guidelines. Multinomial and ordinal logistic regressions were conducted adjusted on sex, age, BMI, education, smoking and use of inhaled corticosteroids. The association between air pollution and the three domains of asthma control (symptoms, exacerbations and lung function) was assessed. Odds Ratios (ORs) are reported per Inter Quartile Range (IQR). Results Median concentrations (μg.m−3) were 32(IQR 25–38) for NO2 (n=465), 46(41–52) for O3 and 21(18–21) for PM10 (n=481). In total, 44%, 29% and 27% had controlled, partly-controlled and uncontrolled asthma. The ordinal ORs for O3 and PM10 with asthma control were 1.69(95%CI 1.22–2.34) and 1.35(95%CI 1.13–1.64) respectively. When including both pollutants in the same model, both associations persisted. Associations were not modified by sex, smoking status, use of inhaled corticosteroids, atopy, season of examination or BMI. Both pollutants were associated with each of the three main domains of control. Conclusions The results suggest that long-term exposure to PM10 and O3 is associated with uncontrolled asthma in adults, defined by symptoms, exacerbations and lung function. Abstract Word count: 250 Key words: air pollution, asthma, asthma control PMID:21690606

  18. A comparative study of compression-expansion type dehumidification systems to achieve low dew point air

    International Nuclear Information System (INIS)

    Moon, Choon; Bansal, Pradeep

    2009-01-01

    This paper presents a theoretical feasibility study of three dehumidification systems to achieve air with dew points down to (-) 40 deg. C. The systems consist of compressors, heat exchangers, expanders and heaters. A thermodynamic model has been developed of the systems to study the effect of the compressor, expander, and heat recovery heat exchanger efficiency as a function of pressure ratio, net required work, quantity of condensed moisture, and system outlet dew point temperature. The analysis has revealed that the selection of a heat recovery heat exchanger is critical for an efficient dehumidification system, where compressor efficiency has the dominant effect on power consumption.

  19. Studies on plant extracts as corrosion inhibitors for mild steel in air saturated water

    International Nuclear Information System (INIS)

    Mohamad Daud; Abdul Razak Daud; Zainal Abidin Sidi

    1988-01-01

    The effectiveness in inhibiting corrosion by garlic, soya bean, and tobacco extracts and their combinations in air saturated water at ambient temperature were studied by using electrochemical corrosion test. The range of inhibitor concentration studied was from 0.1 to 1.0 g/l. The variations of corrosion potential and corrosion current density was recorded and the results showed that the extracts have inhibitive properties in the corrosion of mild stee. The effectiveness of the inhibitors is in the following order: extract mixture > tobacco > garlic > soya bean extracts. (author)

  20. Pilot study investigating ambient air toxics emissions near a Canadian kraft pulp and paper facility in Pictou County, Nova Scotia.

    Science.gov (United States)

    Hoffman, Emma; Guernsey, Judith R; Walker, Tony R; Kim, Jong Sung; Sherren, Kate; Andreou, Pantelis

    2017-09-01

    Air toxics are airborne pollutants known or suspected to cause cancer or other serious health effects, including certain volatile organic compounds (VOCs), prioritized by the US Environmental Protection Agency (EPA). While several EPA-designated air toxics are monitored at a subset of Canadian National Air Pollution Surveillance (NAPS) sites, Canada has no specific "air toxics" control priorities. Although pulp and paper (P&P) mills are major industrial emitters of air pollutants, few studies quantified the spectrum of air quality exposures. Moreover, most NAPS monitoring sites are in urban centers; in contrast, rural NAPS sites are sparse with few exposure risk records. The objective of this pilot study was to investigate prioritized air toxic ambient VOC concentrations using NAPS hourly emissions data from a rural Pictou, Nova Scotia Kraft P&P town to document concentration levels, and to determine whether these concentrations correlated with wind direction at the NAPS site (located southwest of the mill). Publicly accessible Environment and Climate Change Canada data (VOC concentrations [Granton NAPS ID: 31201] and local meteorological conditions [Caribou Point]) were examined using temporal (2006-2013) and spatial analytic methods. Results revealed several VOCs (1,3-butadiene, benzene, and carbon tetrachloride) routinely exceeded EPA air toxics-associated cancer risk thresholds. 1,3-Butadiene and tetrachloroethylene were significantly higher (p towns and contribute to poor health in nearby communities.

  1. Children's Health and Indoor Air Quality in Primary Schools and Homes in Portugal-Study Design.

    Science.gov (United States)

    Madureira, Joana; Paciência, Inês; Ramos, Elisabete; Barros, Henrique; Pereira, Cristiana; Teixeira, João Paulo; Fernandes, Eduardo de Oliveira

    2015-01-01

    The main aim of the research project "On the Contribution of Schools to Children's Overall Indoor Air Exposure" is to study associations between adverse health effects, namely, allergy, asthma, and respiratory symptoms, and indoor air pollutants to which children are exposed to in primary schools and homes. Specifically, this investigation reports on the design of the study and methods used for data collection within the research project and discusses factors that need to be considered when designing such a study. Further, preliminary findings concerning descriptors of selected characteristics in schools and homes, the study population, and clinical examination are presented. The research project was designed in two phases. In the first phase, 20 public primary schools were selected and a detailed inspection and indoor air quality (IAQ) measurements including volatile organic compounds (VOC), aldehydes, particulate matter (PM2.5, PM10), carbon dioxide (CO2), carbon monoxide (CO), bacteria, fungi, temperature, and relative humidity were conducted. A questionnaire survey of 1600 children of ages 8-9 years was undertaken and a lung function test, exhaled nitric oxide (eNO), and tear film stability testing were performed. The questionnaire focused on children's health and on the environment in their school and homes. One thousand and ninety-nine questionnaires were returned. In the second phase, a subsample of 68 children was enrolled for further studies, including a walk-through inspection and checklist and an extensive set of IAQ measurements in their homes. The acquired data are relevant to assess children's environmental exposures and health status.

  2. Experimental study on the influence of oxygen content in the combustion air on the combustion characteristics

    International Nuclear Information System (INIS)

    Bělohradský, Petr; Skryja, Pavel; Hudák, Igor

    2014-01-01

    This study was focused on the experimental investigation of the very promising combustion technology called as the oxygen-enhanced combustion (OEC), which uses the oxidant containing higher proportion of oxygen than in the atmospheric air, i.e. more than 21%. The work investigated and compared the characteristics of two OEC methods, namely the premix enrichment and air-oxy/fuel combustion, when the overall oxygen concentration was varied from 21% to 46%. The combustion tests were performed with the experimental two-gas-staged burner of low-NO x type at the burner thermal input of 750 kW for two combustion regimes – one-staged and two-staged combustion. The oxygen concentration in the flue gas was maintained in the neighborhood of 3% vol. (on dry basis). The aim of tests was to assess the impact of the oxidant composition, type of OEC method and fuel-staging on the characteristic combustion parameters in detail. The investigated parameters included the concentration of nitrogen oxides (NO x ) in the flue gas, flue gas temperature, heat flux to the combustion chamber wall, and lastly the stability, shape and dimensions of flame. It was observed that NO x emission is significantly lower when the air-oxy/fuel method is used compared to the premix enrichment method. Moreover, when the fuel was staged, NO x emission was below 120 mg/Nm 3 at all investigated oxygen flow rates. Increasing oxygen concentration resulted in higher heating intensity due to higher concentrations of CO 2 and H 2 O. The available heat at 46% O 2 was higher by 20% compared with that at 21% O 2 . - Highlights: • Premix-enrichment and air-oxy/fuel combustion methods were experimentally studied. • NO x increased sharply as oxygen concentration increased during PE tests. • NO x was below 120 mg/Nm 3 for all investigated oxygen flow rates in AO tests. • Radiative heat transfer was enhanced ca. 20% as O 2 concentration was increased. • OEC flames were observed stable, more luminous and

  3. Study of the air quality in the surroundings of an urban park: A micrometeorological approach

    Science.gov (United States)

    Sastre, Mariano; Yagüe, Carlos; Arrillaga, Jon A.; Román-Cascón, Carlos; Maqueda, Gregorio; Artíñano, Begoña; Díaz-Ramiro, Elías; Gómez-Moreno, Francisco J.; Barreiro, Marcos; Borge, Rafael; Narros, Adolfo; Pérez, Javier; Quaassdorff, Christina

    2017-04-01

    In this work we study the differences showed by two types of pollutants, particulate matter (PM) and NOx, by comparing ambient concentration measurements within an urban park versus the corresponding values nearby (but outside) it. The results are linked to both proximity to emission sources, such as road traffic, and the microscale atmospheric conditions. The work is motivated by the fact that poor air quality is a crucial issue of current cities. For some of them it is not uncommon to face this problem with occasional traffic restrictions when high concentrations of pollutants are reached. These events occur more frequently with specific large-scale atmospheric conditions, for example when a strong anticyclone is present. As the meteorological conditions may significantly influence the pollutants concentrations, the research project TECNAIRE-CM (Innovative technologies for the assessment and improvement of urban air quality) aims to provide new approaches to obtain proper descriptions of the urban pollution and its dynamics at different spatial and temporal scales, not only the synoptic scale. So far, a few field campaigns have been developed within TECNAIRE-CM at two locations in the city of Madrid, which are considered hot spots according to the air quality network records. Here we use the data from a field campaign carried out during summer 2016, which consider standard pollution and meteorological measurements, as well as sonic anemometer data. The latter help to include atmospheric turbulence as a significant agent for air quality characterization. The instrumentation was deployed at a location with considerable traffic density, but nearby a border of the main urban park of the city, so that its influence might be investigated. Supplementary data considered for this work correspond to permanent instrumentation within the park. With this extra information we can compare both measurements inside and outside the park. Therefore, we study the effect on wind

  4. The role of technology, product lifetime, and energy efficiency in climate mitigation: A case study of air conditioners in Japan

    International Nuclear Information System (INIS)

    Nishijima, Daisuke

    2017-01-01

    This study analyzed the impact on the life-cycle CO_2 emissions derived from a specific durable good (i.e., household air conditioners in this study) of industrial technology changes, product lifetime changes, and energy efficiency improvements. I proposed a comprehensive structural decomposition analysis including two factors of average lifetime and energy efficiency trend of household air conditioners and applied the decomposition method to the Japanese environmental input-output tables of 1990, 1995, 2000, and 2005. The empirical results show that “Household air-conditioner sector” itself contributed to reducing life-cycle CO_2 emissions derived from household air conditioners, while other sectors such as “On-site power generation sector” and “Retail trade sector” contributed to increasing life-cycle CO_2 emissions derived from household air conditioners. I also conducted combined scenario analysis about reduction potential of product lifetime and energy efficiency of air conditioners and the results showed the reduction rate of energy efficiency necessary for maintain CO_2 emissions in 2005 at 1990 level on each average lifetime scenario. (e.g. if average lifetime of air conditioners is shortened by 1 year, energy efficiency of air conditioners have to be further improved by 20.6% from current level. - Highlights: • This study provides a decomposition framework for air conditioner’s CO_2 emissions. • Technology, product lifetime and energy efficiency are considered in the framework. • “Household air conditioner” sector contributed to reducing CO_2 emissions largely. • “On-site power generation” indirectly contributed to increasing CO_2 emissions. • I showed the improvement rates of energy efficiency to achieve a reduction target.

  5. Operational evaluation of the RLINE dispersion model for studies of traffic-related air pollutants

    Science.gov (United States)

    Milando, Chad W.; Batterman, Stuart A.

    2018-06-01

    Exposure to traffic-related air pollutants (TRAP) remains a key public health issue, and improved exposure measures are needed to support health impact and epidemiologic studies and inform regulatory responses. The recently developed Research LINE source model (RLINE), a Gaussian line source dispersion model, has been used in several epidemiologic studies of TRAP exposure, but evaluations of RLINE's performance in such applications have been limited. This study provides an operational evaluation of RLINE in which predictions of NOx, CO and PM2.5 are compared to observations at air quality monitoring stations located near high traffic roads in Detroit, MI. For CO and NOx, model performance was best at sites close to major roads, during downwind conditions, during weekdays, and during certain seasons. For PM2.5, the ability to discern local and particularly the traffic-related portion was limited, a result of high background levels, the sparseness of the monitoring network, and large uncertainties for certain processes (e.g., formation of secondary aerosols) and non-mobile sources (e.g., area, fugitive). Overall, RLINE's performance in near-road environments suggests its usefulness for estimating spatially- and temporally-resolved exposures. The study highlights considerations relevant to health impact and epidemiologic applications, including the importance of selecting appropriate pollutants, using appropriate monitoring approaches, considering prevailing wind directions during study design, and accounting for uncertainty.

  6. The Texas Air Quality Study: State of the Science of Ozone and Particulate Matter formation in Texas and Implications for Air Quality Policy

    Science.gov (United States)

    Allen, D. T.

    2002-05-01

    The Texas Air Quality Study (TexAQS) was performed during August and September of 2000; approximately 300 investigators from around the world made measurements of air pollutant concentrations and meteorological variables in southeast Texas. Five aircraft were deployed; five major ground chemistry sites were established and approximately 20 peripheral sites were established for collecting additional meteorological and chemical data. The scope, goals and preliminary results are available at the study web sites (www.utexas.edu/research/ceer/texaqs and www.utexas.edu/research/ceer/texaqsarchive). This presentation will provide an overview of the main findings from the study and will describe the role that ongoing data analysis activities are having on the development of air quality policy in the State of Texas. Some of the major findings are: Finding 1. Almost without exception, air parcels with very high ozone concentrations, observed by aircraft during the Texas Air Quality Study, had back trajectories that indicated a substantial contribution of emissions from industrial source regions. These air parcels also had chemical compositions that were representative of industrial sources, rather than typical urban sources. Finding 2: The rate of ozone production in and around the industrial source dominated areas in Houston can be very high, commonly exceeding 50 ppb/hr, and at times approaching instantaneous rates of 200 ppb/hr. Finding 3: The efficiency of ozone production in and around the industrial source dominated areas in Houston can be very high, ranging from 10-20 molecules of ozone per molecule of reacted NOx. Finding 4. Ozone production in the Houston urban plume was found to be slower and less efficient than in the composite industrial plume from the Ship Channel region and in plumes from isolated petrochemical facilities. Finding 5. The high rates and high efficiencies of ozone production in the industrial plumes are driven by high concentrations of reactive

  7. Configuration Studies of Personal Air Vehicles. Personal Air Vehicle and Flying Jeep Concepts: A Commentary on Promising Approaches or What Goes Around Comes Around (About Every Twenty Years)

    Science.gov (United States)

    Hall, David W.

    2001-01-01

    The NASA/Langley Personal Air Vehicle (PAV) Exploration (PAVE) and the DARPA (Defense Advanced Research Projects Agency) Dual Air/Road Transportation System (DARTS) projects were established to investigate the feasibility of creating vehicles which could replace, or at the very least augment, personal ground and air transportation schemes. This overall goal implies integrating several technology areas with practical everyday transportation requirements to design a class of vehicles which will achieve the following goals: (1) Vertical, Extremely Short, or Short Takeoff and Landing (VTOL, ESTOL, STOL) capability; (2) Operation at block speeds markedly faster than current combinations of land and air transportation, particularly in critical market areas; (3) Unit cost comparable to current luxury cars and small general aviation aircraft; (4) Excellent reliability; (5) Excellent safety; (6) Ability to integrate with existing land and air transportation systems. The conclusions of these configuration studies are summarized as follows: (1) Creation of the five assigned configurations prompted added explorations, some of which were dead-ends; (2) Some components could be common to all configurations such as avionics and dual-mode suspension schemes; (3) Single-Mode PAVs can be created by removing dual-mode-specific items; (4) Aviation history provided some intriguing starting points, as in what goes around comes around; (5) CTOL (Conventional Take-off and Landing) and STOL dual-mode PAVs look feasible with single-mode PAVs being simplifications of the dual-mode approach; (6) VTOL PAVs will require development; (7) More exotic collapsing mechanisms mechanisms need development; (8) As a teaching tool, PAVs are not yet a well-enough bounded design problem.

  8. Study on the relationship between the opening of environmental tax and the prevention and control of air pollution in China

    Science.gov (United States)

    Gao, Guilin; Wang, Tianyi

    2018-03-01

    This article systematically expounds the status quo and sources of air pollution, the experience of foreign environmental tax policy, the advantages and disadvantages of environmental taxes levied in our country through literature research, historical analysis and comparative analysis and put forward recommendations on tax policy of prevention and control of air pollution by combining with the specific national conditions in our country. As one of the basic means of national macro-control, the tax policy is the major countermeasure that cannot be ignored in the prevention and control of air pollution. Studying the tax policy of prevention and control of air pollution will help to effectively control air pollution, develop a green economy and recycle economy and achieve the goal of improving environmental quality.

  9. Research on Value Assessment and Compensation for Health Hazards of Urban Air Pollution-A Case Study of Urumqi

    Directory of Open Access Journals (Sweden)

    Chen Yu

    Full Text Available ABSTRACT With the acceleration of urbanization and industrialization, urban air pollution has become a serious threat to the health of urban residents. In this study, to investigate health hazards caused by air pollution for urban residents, concentrations of main air pollutants and annual coal consumption amounts during the period from 2000 to 2013 were analyzed. Our results showed that economic losses of Urumqi caused by air pollution amounted to 63.155 million yuan in 2013, accounting for 0.2 ‰ of its GDP and 5.7% of public utility expenditures for that year. The compensation mechanism analysis suggested that it is necessary to further improve the health care system and increase corporate environmental taxes. More environmental health protection taxes should be levied on key monitoredenterprises in Urumqi to achieve effective compensations for urban residents affected by air pollution-related health hazards.

  10. Oil and gas impacts on air quality in federal lands in the Bakken region: an overview of the Bakken Air Quality Study and first results

    Directory of Open Access Journals (Sweden)

    A. J. Prenni

    2016-02-01

    Full Text Available The Bakken formation contains billions of barrels of oil and gas trapped in rock and shale. Horizontal drilling and hydraulic fracturing methods have allowed for extraction of these resources, leading to exponential growth of oil production in the region over the past decade. Along with this development has come an increase in associated emissions to the atmosphere. Concern about potential impacts of these emissions on federal lands in the region prompted the National Park Service to sponsor the Bakken Air Quality Study over two winters in 2013–2014. Here we provide an overview of the study and present some initial results aimed at better understanding the impact of local oil and gas emissions on regional air quality. Data from the study, along with long-term monitoring data, suggest that while power plants are still an important emissions source in the region, emissions from oil and gas activities are impacting ambient concentrations of nitrogen oxides and black carbon and may dominate recent observed trends in pollutant concentrations at some of the study sites. Measurements of volatile organic compounds also definitively show that oil and gas emissions were present in almost every air mass sampled over a period of more than 4 months.

  11. Status of Air Quality in Central California and Needs for Further Study

    Science.gov (United States)

    Tanrikulu, S.; Beaver, S.; Soong, S.; Tran, C.; Jia, Y.; Matsuoka, J.; McNider, R. T.; Biazar, A. P.; Palazoglu, A.; Lee, P.; Wang, J.; Kang, D.; Aneja, V. P.

    2012-12-01

    Ozone and PM2.5 levels frequently exceed NAAQS in central California (CC). Additional emission reductions are needed to attain and maintain the standards there. Agencies are developing cost-effective emission control strategies along with complementary incentive programs to reduce emissions when exceedances are forecasted. These approaches require accurate modeling and forecasting capabilities. A variety of models have been rigorously applied (MM5, WRF, CMAQ, CAMx) over CC. Despite the vast amount of land-based measurements from special field programs and significant effort, models have historically exhibited marginal performance. Satellite data may improve model performance by: establishing IC/BC over outlying areas of the modeling domain having unknown conditions; enabling FDDA over the Pacific Ocean to characterize important marine inflows and pollutant outflows; and filling in the gaps of the land-based monitoring network. BAAQMD, in collaboration with the NASA AQAST, plans to conduct four studies that include satellite-based data in CC air quality analysis and modeling: The first project enhances and refines weather patterns, especially aloft, impacting summer ozone formation. Surface analyses were unable to characterize the strong attenuating effect of the complex terrain to steer marine winds impinging on the continent. The dense summer clouds and fog over the Pacific Ocean form spatial patterns that can be related to the downstream air flows through polluted areas. The goal of this project is to explore, characterize, and quantify these relationships using cloud cover data. Specifically, cloud agreement statistics will be developed using satellite data and model clouds. Model skin temperature predictions will be compared to both MODIS and GOES skin temperatures. The second project evaluates and improves the initial and simulated fields of meteorological models that provide inputs to air quality models. The study will attempt to determine whether a cloud

  12. Optimal study of a solar air heating system with pebble bed energy storage

    International Nuclear Information System (INIS)

    Zhao, D.L.; Li, Y.; Dai, Y.J.; Wang, R.Z.

    2011-01-01

    Highlights: → Use two kinds of circulation media in the solar collector. → Air heating and pebble bed heat storage are applied with different operating modes. → Design parameters of the system are optimized by simulation program. → It is found that the system can meet 32.8% of the thermal energy demand in heating season. → Annual solar fraction aims to be 53.04%. -- Abstract: The application of solar air collectors for space heating has attracted extensive attention due to its unique advantages. In this study, a solar air heating system was modeled through TRNSYS for a 3319 m 2 building area. This air heating system, which has the potential to be applied for space heating in the heating season (from November to March) and hot water supply all year around in North China, uses pebble bed and water storage tank as heat storage. Five different working modes were designed based on different working conditions: (1) heat storage mode, (2) heating by solar collector, (3) heating by storage bed, (4) heating at night and (5) heating by an auxiliary source. These modes can be operated through the on/off control of fan and auxiliary heater, and through the operation of air dampers manually. The design, optimization and modification of this system are described in this paper. The solar fraction of the system was used as the optimization parameter. Design parameters of the system were optimized by using the TRNSYS program, which include the solar collector area, installation angle of solar collector, mass flow rate through the system, volume of pebble bed, heat transfer coefficient of the insulation layer of the pebble bed and water storage tank, height and volume of the water storage tank. The TRNSYS model has been verified by data from the literature. Results showed that the designed solar system can meet 32.8% of the thermal energy demand in the heating season and 84.6% of the energy consumption in non-heating season, with a yearly average solar fraction of 53.04%.

  13. Feasibility study of a hybrid wind turbine system – Integration with compressed air energy storage

    International Nuclear Information System (INIS)

    Sun, Hao; Luo, Xing; Wang, Jihong

    2015-01-01

    Highlights: • A new hybrid wind turbine system is proposed and feasibility study if conducted. • A complete mathematical model is developed and implemented in a software environment. • Multi-mode control strategy is investigated to ensure the system work smoothly and efficiently. • A prototype for implementing the proposed mechanism is built and tested as proof of the concept. • The proposed system is proved to be technically feasible with energy efficiency around 50%. - Abstract: Wind has been recognized as one of major realistic clean energy sources for power generation to meet the continuously increased energy demand and to achieve the carbon emission reduction targets. However, the utilisation of wind energy encounters an inevitable challenge resulting from the nature of wind intermittency. To address this, the paper presents the recent research work at Warwick on the feasibility study of a new hybrid system by integrating a wind turbine with compressed air energy storage