WorldWideScience

Sample records for air cleaning systems

  1. Studies of Incinerator Air Cleaning Systems

    International Nuclear Information System (INIS)

    The purpose of this paper is to report on the experimental results obtained with a small institutional radioactive waste incinerator and a gas cleaning system designed and constructed at the Korean Atomic Energy Research Institute. The system consists of an incinerator with overfire and tangential air supply, a dilution valve, a two-stage cyclone collector, a heat-exchanger, a filter of domestic technical-grade glass fibre and an electrostatic precipitator for final collection of the particles within the flue gas. The particle collection efficiency of the gas cleaning units was measured and the distribution of the particle size at each unit was investigated. Sawdust charges with different concentrations of radioactive tracers, 198Au, 51Cr and 35S, were burned and the radioactive concentrations at the downstream end of the system were measured. As a result of the experiment, the following units may be recommended as a standard incineration system for small laboratories in countries where filters or electrostatic precipitators are difficult to obtain or expensive, (1) incinerator with tangential firing, (2) dilution valve, (3) two-stage cyclone collector, (4) roughening filter of technical-grade glass fibre. (author)

  2. Air cleaning system isolation during tornado conditions

    International Nuclear Information System (INIS)

    The occurrence of a tornado at the site of an operating nuclear power generating station creates unstable atmospheric conditions which can be detrimental to the proper operation of the plant air cleaning system. One means of mitigating or preventing this hazard is isolation of the system from the unstable environment by closure of the system openings during the unstable conditions. For maximum system protection the closure should be an automatic response to the adverse conditions themselves, without reliance on manual or remote sensing or signals. The interaction of tornado characteristics with velocity/pressure sensitive isolation devices is modeled. Force and time relationships are investigated to evaluate and predict the interaction. Laboratory test apparatus is developed for simulating the flows and pressures induced by the tornado at system openings. Several isolation devices of various sizes are subjected to a range of simulated tornado conditions for observation and evaluation of response time, sensitivity, and dyamic closing forces. The model, apparatus, experimentation, and results are presented

  3. Prototype air cleaning system for a firing range

    Energy Technology Data Exchange (ETDEWEB)

    Glissmeyer, J.A.; Mishima, J.; Bamberger, J.A.

    1985-01-01

    This report recommends air cleaning system components for the US Army Ballistics Research Laboratory's new large-caliber firing range, which is used for testing depleted uranium (DU) penetrators. The new air cleaning system has lower operating costs during the life of the system compared to that anticipated for the existing air cleaning system. The existing system consists of three banks of filters in series; the first two banks are prefilters and the last are high-efficiency particulate air (HEPA) filters. The principal disadvantage of the existing filters is that they are not cleanable and reusable. Pacific Northwest Laboratory focused the search for alternate air cleaning equipment on devices that do not employ liquids as part of the particle collection mechanism. Collected dry particles were assumed preferable to a liquid waste stream. The dry particle collection devices identified included electrostatic precipitators; inertial separators using turning vanes or cyclones; and several devices employing a filter medium such as baghouses, cartridge houses, cleanable filters, and noncleanable filters similar to those in the existing system. The economics of practical air cleaning systems employing the dry particle collection devices were evaluated in 294 different combinations. 7 references, 21 figures, 78 tables.

  4. New challenges to air/gas cleaning systems

    Energy Technology Data Exchange (ETDEWEB)

    Kovach, J.L. [NUCON International, Inc., Columbus, OH (United States)

    1997-08-01

    This paper discusses the need for changes in the design and manufacturing of air and gas cleaning systems to meet waste management and site remediation requirements. Current design and manufacturing practices are primarily directed toward evaluating operational problems with existing systems in nuclear reactor facilities. However, nuclear waste management needs have developed which are much broader in scope and have different processing conditions. Numerous examples of air cleaning needs for waste management activities are provided; the major differences from operating facility needs are the requirement for continuous effluent treatment under widely different processing conditions. Related regulatory issues are also discussed briefly. 1 ref.

  5. Air Cleaning Devices for HVAC Supply Systems in Schools. Technical Bulletin.

    Science.gov (United States)

    Wheeler, Arthur E.

    Guidelines for maintaining indoor air quality in schools with HVAC air cleaning systems are provided in this document. Information is offered on the importance of air cleaning, sources of air contaminants and indoor pollutants, types of air cleaners and particulate filters used in central HVAC systems, vapor and gas removal, and performance…

  6. Investigation of air cleaning system response to accident conditions

    International Nuclear Information System (INIS)

    Air cleaning system response to the stress of accident conditions are being investigated. A program overview and hghlight recent results of our investigation are presented. The program includes both analytical and experimental investigations. Computer codes for predicting effects of tornados, explosions, fires, and material transport are described. The test facilities used to obtain supportive experimental data to define structural integrity and confinement effectiveness of ventilation system components are described. Examples of experimental results for code verification, blower response to tornado transients, and filter response to tornado and explosion transients are reported

  7. Investigation of air cleaning system response to accident conditions

    International Nuclear Information System (INIS)

    We are investigating air cleaning system response to the stress of accident conditions. In this paper we present a program overview and highlight recent results of our investigations. The program includes both analytical and experimental investigations. Computer codes for predicting effects of tornados, explosions, fires, and material transport are described. We also describe the test facilities we use to obtain supportive experimental data to define structural integrity and confinement effectiveness of ventilation system components. Examples of experimental results for code verification, blower response to tornado transients, and filter response to tornado and explosion transients are reported

  8. USNRC regulatory guidance for engineered safety feature air cleaning systems

    International Nuclear Information System (INIS)

    The need for clear, technically appropriate, and easily implementable guidance for the design, testing, and maintenance of nuclear air cleaning systems has long been recognized. Numerous industry consensus standards have been issued and revised over the last 30 years. Guidance has also been published by the US Nuclear Regulatory Commission in the form of regulations, regulatory guides, standard review plans, NUREG documents, and information notices. This paper will summarize the latest revisions to these documents and emphasize Regulatory Guide 1.52, Design, Testing, and Maintenance Criteria for Post-Accident Engineered-Safety-Feature Atmosphere Cleanup System Air Filtration and Adsorption Units of Light-Water-Cooled Nuclear Power Plants, which was last revised in 1978. The USNRC has undertaken a project to revise this regulatory guide, and the status of that revision is highlighted

  9. Combined filtering facilities for nuclear air cleaning systems

    International Nuclear Information System (INIS)

    Full text of publication follows: The choice of an optimal cleaning technology and cleaning system design depends on the specificity of the provision of the ecological safety of NPP under operation and accident conditions. The major requirements imposed on such systems are to achieve high efficiency (99,0-99,95 %) and reliability. In this respect, the important problem is to develop combined filtering facilities (CFF) which are able within the same aggregate to provide complex cleaning of air from moisture, radioactive aerosols, iodine in molecular (I2) and organic (CH3I) forms. A great experience accumulated at SSC RF IPPE and other organizations in the course of researches dealing with construction of aerosol filters and iodine filters-sorbers for NPPs and radio-chemical plants made it possible to develop a pilot mock-up facility providing complex cleaning of air from radioactive aerosols and iodine in reference to the real ventilation conditions at the First in the World Nuclear Power Plant. By now complex tests of the mock-up specimen of the UFK-3500 facility have been run with the aim of determining the functional efficiency of its separate filtering sections in terms of droplet moisture, atmospheric and radioactive aerosols and radioiodine and its organic compounds as well as of the filtering facility as a whole. Control over aerosol and radioiodine concentrations and volumetric activity was performed using laser and gamma spectrometry. The obtained data give necessary grounds to formulate the recommendations, how to develop and organize production of combined filtering facilities for flow rates of the medium to be cleaned of 3500, 7000, 10500 m3/h. The production is organized on the basis of OAO PZ 'Signal' in Obninsk. Provision is made for using small capacity small size filters (for radiochemical plants and research test facilities and rigs) and high efficiency sorbers (for commercial NPP) as filters-sorbers. To date the design plans and specifications

  10. Consistent approach to air-cleaning system duct design

    International Nuclear Information System (INIS)

    Nuclear power plant air-cleaning system effectiveness is dependent on the capability of a duct system to safely convey contaminated gas to a filtration unit and subsequently to a point of discharge. This paper presents a logical and consistent design approach for selecting sheet metal ductwork construction to meet applicable criteria. The differences in design engineers' duct construction specifications are acknowledged. Typical duct construction details and suggestions for their effective use are presented. Improvements in duct design sections of ANSI/ASME N509-80 are highlighted. A detailed leakage analysis of a control room HVAC system is undertaken to illustrate the effects of conceptual design variations on duct construction requirements. Shortcomings of previously published analyses and interpretations of a current standard are included

  11. The Clean Air Act

    International Nuclear Information System (INIS)

    The Clean Air Act amendments alter the complex laws affecting atmospheric pollution and at the same time have broad implications for energy. Specifically, the Clean Air Act amendments for the first time deal with the environmental problem of acid deposition in a way that minimizes energy and economic impacts. By relying upon a market-based system of emission trading, a least cost solution will be used to reduce sulfur dioxide (SO2) emissions by almost 40 percent. The emission trading system is the centerpiece of the Clean Air Act (CAA) amendments effort to resolve energy and environmental interactions in a manner that will maximize environmental solutions while minimizing energy impacts. This paper will explore how the present CAA amendments deal with the emission trading system and the likely impact of the emission trading system and the CAA amendments upon the electric power industry

  12. Aerosol challenges to air cleaning systems during severe accidents in nuclear plants

    International Nuclear Information System (INIS)

    A variety of air cleaning systems may be operating in nuclear power plants and under severe accident conditions, these systems may be treating airborne concentrations of aerosols which are very high. Predictions of airborne aerosol concentrations in nuclear power plant containments under severe accident conditions are reviewed to provide a basis for evaluating the potential effects on the air cleaning systems. The air cleaning systems include filters, absorber beds, sprays, water pools, ice beds, and condensers. Not all of these were intended to operate as air cleaners but will in fact be good aerosol collectors. Knowledge of expected airborne concentrations will allow better evaluation of system performances

  13. Air-cleaning systems for sodium-fire-aerosol control. [LMFBR

    Energy Technology Data Exchange (ETDEWEB)

    Hilliard, R.K.; Muhlestein, L.D.

    1982-05-01

    A development program has been carried out at the Hanford Engineering Development Laboratory (HEDL) with the purpose of developing and proof testing air cleaning components and systems for use under severe sodium fire conditions, including those involving high levels of radioactivity. The air cleaning components tested can be classified as either dry filters or aqueous scrubbers. Test results are presented.

  14. Nuclear air cleaning

    International Nuclear Information System (INIS)

    This report briefly describes the history of the use of high- efficiency particulate air filters for air cleaning at nuclear installations in the United States and discusses future uses of such filters

  15. Research and development on air cleaning system of reprocessing plant in Japan

    International Nuclear Information System (INIS)

    Present status in Japan of R and D on air cleaning systems, especially of the fuel reprocessing plant is summarized. The description is centered on the R and D and experience of Tokai-reprocessing plant, which covers the plant air cleaning system, effort carried out for decreasing I2 effluence in the actual vented off-gas, and R and D for recovery of Kr and 3H. Some experimental results for the evaluation of HEPA filter are also described

  16. Air Cleaning Technologies

    Science.gov (United States)

    2005-01-01

    zoster, whereas close contact is required for the direct transmission of infectious diseases transmitted by droplets, such as influenza (the flu) and SARS. The Technology In-room air cleaners are supplied as portable or fixed devices. Fixed devices can be attached to either a wall or ceiling and are preferred over portable units because they have a greater degree of reliability (if installed properly) for achieving adequate room air mixing and airflow patterns, which are important for optimal effectiveness. Through a method of air recirculation, an in-room air cleaner can be used to increase room ventilation rates and if used to exhaust air out of the room it can create a negative-pressure room for airborne infection isolation (AII) when the building’s HVAC system cannot do so. A negative-pressure room is one where clean air flows into the room but contaminated air does not flow out of it. Contaminated room air is pulled into the in-room air cleaner and cleaned by passing through a series of filters, which remove the airborne infectious pathogens. The cleaned air is either recirculated into the room or exhausted outside the building. By filtering contaminated room air and then recirculating the cleaned air into the room, an in-room air cleaner can improve the room’s ventilation. By exhausting the filtered air to the outside the unit can create a negative-pressure room. There are many types of in-room air cleaners. They vary widely in the airflow rates through the unit, the type of air cleaning technology used, and the technical design. Crucial to maximizing the efficiency of any in-room air cleaner is its strategic placement and set-up within a room, which should be done in consultation with ventilation engineers, infection control experts, and/or industrial hygienists. A poorly positioned air cleaner may disrupt airflow patterns within the room and through the air cleaner, thereby compromising its air cleaning efficiency. The effectiveness of an in-room air cleaner

  17. Sample and injection manifolds used to in-place test of nuclear air-cleaning system

    International Nuclear Information System (INIS)

    Objective: According to the regulations of nuclear safety rules and related standards, in-place test of the nuclear air-cleaning systems should be carried out before and during operation of the nuclear facilities, which ensure them to be in good condition. In some special conditions, the use of sample and injection manifolds is required to make the test tracer and ventilating duct air fully mixed, so as to get the on-spot typical sample. Methods: This paper introduces the technology and application of the sample and injection manifolds in nuclear air-cleaning system. Results: Multi point injection and multi point sampling technology as an effective experimental method, has been used in a of domestic and international nuclear facilities. Conclusion: The technology solved the problem of uniformly of on-spot injection and sampling,which plays an important role in objectively evaluating the function of nuclear air-cleaning system. (authors)

  18. Air-cleaning apparatus

    International Nuclear Information System (INIS)

    An air-cleaning, heat-exchange apparatus includes a main housing portion connected by means of an air inlet fan to the kitchen exhaust stack of a restaurant. The apparatus includes a plurality of heat exchangers through which a heat-absorptive fluid is circulated, simultaneously, by means of a suitable fluid pump. These heat exchangers absorb heat from the hot exhaust gas, out of the exhaust stack of the restaurant, which flows over and through these heat exchangers and transfers this heat to the circulating fluid which communicates with remote heat exchangers. These remote heat exchangers further transfer this heat to a stream of air, such as that from a cold-air return duct for supplementing the conventional heating system of the restaurant. Due to the fact that such hot exhaust gas is heavily grease laden , grease will be deposited on virtually all internal surfaces of the apparatus which this exhaust gas contacts. Consequently, means are provided for spraying these contacted internal surfaces , as well as the hot exhaust gas itself, with a detergent solution in which the grease is soluble, thereby removing grease buildup from these internal surfaces

  19. Indonesia's Clean Air Program

    OpenAIRE

    Budy P. Resosudarmo

    2002-01-01

    Unprecedented industrial development in Indonesia during the last two decades, accompanied by a growing population, has increased the amount of environmental damage. One of the most important environmental problems is that the level of air pollution in several large cities has become alarming, particularly in the last few years. This high pollution level has stimulated the government to develop a national clean air program designed to control the quantity of pollutants in the air. However, th...

  20. Performance evaluation of control room HVAC and air cleaning systems under accident conditions

    International Nuclear Information System (INIS)

    In light water reactors, control rooms and technical support centers must be designed to provide habitable environments in accordance with the requirements specified in General Design Criterion 19 of Appendix A, 10 CFR Part 50. Therefore, the effectiveness of HVAC and air cleaning system designs with respect to plant operator protection has to be evaluated by the system designer. Guidance for performing the analysis has been previously given in ANSI/ASME N509-1980 as well as in presentations at past Air Cleaning Conferences. The previous work is extended and the methodology used in a generic, interactive computer program that performs Main Control Room and Technical Support Center (TSC) habitability analyses for LWR nuclear power plants is presented. For given accident concentrations of radionuclides or hazardous gases in the outdoor air intakes and plant spaces surrounding the Main Control Room (or TSC), the program models the performance of the HVAC and air cleaning system designs, and determines control room (or TSC) contaminant concentrations and plant operator protection factors. Calculated or actual duct leakage, air cleaning efficiency, and airborne contamination are taken into account. Flexibility of the model allows for the representation of most control rooms (or TSC) and associated HVAC and air cleaning system conceptual designs that have been used by the US architect/engineers. The program replaced tedious calculations to determine the effects of HVAC ductwork and equipment leakage and permits (1) parametric analyses of various HVAC system design options early in the conceptual phase of a project, and (2) analysis of the effects of leakage test results on contaminant room concentrations, and therefore operator doses

  1. Off-gas and air cleaning systems for accident conditions in nuclear power plants

    International Nuclear Information System (INIS)

    This report surveys the design principles and strategies for mitigating the consequences of abnormal events in nuclear power plants by the use of air cleaning systems. Equipment intended for use in design basis accident and severe accident conditions is reviewed, with reference to designs used in IAEA Member States. 93 refs, 48 figs, 23 tabs

  2. Nuclear air cleaning programs in USA

    International Nuclear Information System (INIS)

    The paper describes air cleaning research activities in the United States nuclear program other than those described in the various papers presented at the conference. First described are those related to aerosol and particulate cleaning generic programs. Discussed next are air cleaning regulations and standards. Specific activities underway in developing air cleaning information and processes for specific areas are discussed beginning with the support of nuclear reactors, e.g., the Electric Power Research Institute programs on reactor accident phenomena and the Savannah River Site program related to aerosol and adsorber research. Finally, the limited research activities in support of air cleaning systems for nuclear fuel reprocessing are described

  3. Clean air Hamilton

    Energy Technology Data Exchange (ETDEWEB)

    McCarry, B.E. [McMaster Univ., Hamilton, ON (Canada)

    2002-07-01

    The industrial City of Hamilton is located on Lake Ontario, downwind from the Ohio Valley. The Hamilton Air Quality Initiative (HAQI) was divided in several phases, one of which is Clean Air Hamilton. This most recent phase was described in this presentation. Two major goals of this phase were: to ensure that the City of Hamilton has the best air quality of any major urban area in Ontario, and to reduce the emissions of greenhouse gases by 20 per cent compared to the levels in 1990. There were five main objectives to this initiative, namely: (1) the identification of priority air quality issues, (2) achieving an understanding of air quality issues, (3) the identification of sources, the evaluation of impacts and the recommendation of solutions, (4) the assessment of human health, and (5) the identification of further research. The reduction of air quality impacts is progressing through the support provided to the Drive Clean Program, the discouragement of vehicle idling, the support to car pooling initiatives, and the promotion of green vehicles. The implementation of pollution control technologies is taking place on the industrial side, as well as the development of plans to reduce steel industry emissions, the development of energy conservation measures and the promotion of green building practices. Efforts are being deployed over fleet greening partnerships, community tree planting program, an international air conference, an electronic information network linking the United States and the communities of Southern Ontario, a road dust study, a truck emissions research project, the assessment of human health impacts, and finally methods for the monitoring of local improvements. figs.

  4. Canada's Clean Air Act

    International Nuclear Information System (INIS)

    This paper provided an outline of Canada's Clean Air Act and examined some of the regulatory changes that will occur as a result of its implementation. The Act is being introduced to strengthen the legislative basis for taking action on reducing air pollution and GHGs, and will allow the government to regulate both indoor and outdoor air pollutants and GHGs. The Act will require the Ministers of the Environment and Health to establish national air quality objectives, as well as to monitor and report on their attainment. The Canadian Environmental Protection Act will be amended to enable the government to regulate the blending of fuels and their components. The Motor Vehicle Fuel Consumption Standards Act will also be amended to enhance the government's authority to regulate vehicle fuel efficiency. The Energy Efficiency Act will also be expanded to allow the government to set energy efficiency standards and labelling requirements for a wider range of consumer and commercial products. The Act will commit to short, medium and long-term industrial air pollution targets. Regulations will be proposed for emissions from industry; on-road and off-road vehicles and engines; and consumer and commercial products. It was concluded that the Government of Canada will continue to consult with provinces, territories, industries and Canadians to set and reach targets for the reduction of both indoor and outdoor air pollutants and GHG emissions. 6 figs

  5. Operation experience feedback and analysis of nuclear air cleaning system in nuclear power plant

    International Nuclear Information System (INIS)

    High-efficiency particulate air filter (HEPA Filter) and Charcoal Adsorber are the most important components affecting the performance of nuclear air cleaning system (NACS) in Nuclear Power Plant. Based on the configuration of HEPA Filter and Charcoal Adsorber, firstly, discussing the factors affecting the components performance and the potential aging parts, and then analyzing the effectiveness of In-place testing for performance surveillance. At last, analyzing the operation experience, and coming to the conclusion that the stable operation of NACS should consider design, initial acceptance testing, period in-place testing, proper maintenance, strict replace schedule, and so on. (authors)

  6. Design of off-gas and air cleaning systems at nuclear power plants

    International Nuclear Information System (INIS)

    The primary purpose of this report is to describe the current design of air and process off-gas cleaning technologies used in nuclear power plants (NPPs). Because of the large inventory of fission products that are produced in the fuel (i.e. in the range of 5x1019Bq per GW(e)·a) and the highly restrictive airborne radionuclide release limits being established by Member States, air and process off-gas cleaning technologies are constantly being improved to provide higher airborne radionuclide recovery efficiencies and a smaller probability of malfunction. For various technologies considered an attempt has been made to provide the following information: (a) Process description in terms of principles of off-gas and air cleaning, operating parameters and system performance; (b) Design for normal and accident situations; (c) Design of components with regard to construction materials, size, shape and geometry of the system, resistance to chemical and physical degradation from the operational environment, safety and quality assurance requirements

  7. Air cleaning in accident situations

    International Nuclear Information System (INIS)

    The Organization for Economic Co-Operation and Development (OECD) through its subsidiaries the Nuclear Energy Agency (NEA) and the Committee on the Safety of Nuclear Installations (CSNI) established in 1979 a Group of Experts or Air Cleaning in Accident Situations. This group met seven times to establish a draft report based on its Terms of Reference which were to: 1) review the performance of off-gas cleaning systems in accident conditions; 2) collect information about operating experience with these systems; 3) seek to establish common principles for the design of off-gas systems; 4) review methods used in the different countries for testing filters from the standpoint of accident conditions; and 5) suggest specific mechanisms for improving cooperation, with regard, for example, to filter testing. The conclusions and recommendations of the Group are summarized

  8. Response of air cleaning system dampers and blowers to simulated tornado transients

    International Nuclear Information System (INIS)

    The effects of tornado-like pressure transients upon dampers and blowers in nuclear air cleaning systems were studied. For the dampers pressure drop as a function of flow rate was obtained and an empirical relationship developed. Transient response was examined for several types of dampers, as was structural integrity. Both centrifugal and axi-vane blowers were tested and transient characteristic curves were generated in outrunning and backflow situations. The transient characteristic curves do not necessarily match the quasi-steady characteristic curves

  9. An introduction to the design, commissioning and operation of nuclear air cleaning systems for Qinshan Nuclear Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    Xinliang Chen; Jiangang Qu; Minqi Shi [Shanghai Nuclear Engineering Research and Design Institute (China)] [and others

    1995-02-01

    This paper introduces the design evolution, system schemes and design and construction of main nuclear air cleaning components such as HEPA filter, charcoal adsorber and concrete housing etc. for Qinshan 300MW PWR Nuclear Power Plant (QNPP), the first indigenously designed and constructed nuclear power plant in China. The field test results and in-service test results, since the air cleaning systems were put into operation 18 months ago, are presented and evaluated. These results demonstrate that the design and construction of the air cleaning systems and equipment manufacturing for QNPP are successful and the American codes and standards invoked in design, construction and testing of nuclear air cleaning systems for QNPP are applicable in China. The paper explains that the leakage rate of concrete air cleaning housings can also be assured if sealing measures are taken properly and embedded parts are designed carefully in the penetration areas of the housing and that the uniformity of the airflow distribution upstream the HEPA filters can be achieved generally no matter how inlet and outlet ducts of air cleaning unit are arranged.

  10. Nuclear air cleaning handbook. Design, construction, and testing of high-efficiency air cleaning systems for nuclear application

    International Nuclear Information System (INIS)

    The handbook is a revision of ORNL/NSIC-65. The purposes of the handbook are to summarize available information in a manner that is useful to the designer, to point out shortcomings in design and construction practice, and to provide guides and recommendations for the design of future systems

  11. Nuclear air cleaning handbook. Design, construction, and testing of high-efficiency air cleaning systems for nuclear application

    Energy Technology Data Exchange (ETDEWEB)

    Burchsted, C.A.; Kahn, J.E.; Fuller, A.B.

    1976-01-01

    The handbook is a revision of ORNL/NSIC-65. The purposes of the handbook are to summarize available information in a manner that is useful to the designer, to point out shortcomings in design and construction practice, and to provide guides and recommendations for the design of future systems. (TFD)

  12. Development of an air cleaning system for dissolving high explosives from nuclear warheads

    International Nuclear Information System (INIS)

    The Department of Energy (DOE) has a major effort underway in dismantling nuclear weapons. In support of this effort we have been developing a workstation for removing the high explosive (HE) from nuclear warheads using hot sprays of dimethyl sulfoxide (DMSO) solvent to dissolve the HE. An important component of the workstation is the air cleaning system that is used to contain DMSO aerosols and vapor and radioactive aerosols. The air cleaning system consists of a condenser to liquefy the hot DMSO vapor, a demister pad to remove most of the DMSO aerosols, a high efficiency particulate air (HEPA) filter to remove the remaining aerosols, an activated carbon filter to remove the DMSO vapor, and a final HEPA filter to meet the redundancy requirement for HEPA filters in radioactive applications. The demister pad is a 4 double-prime thick mat of glass and steel fibers and was selected after conducting screening tests on promising candidates. We also conducted screening tests on various activated carbons and found that all had a similar performance. The carbon breakthrough curves were fitted to a modified Wheeler's equation and gave excellent predictions for the effect of different flow rates. After all of the components were assembled, we ran a series of performance tests on the components and system to determine the particle capture efficiency as a function of size for dioctyl sebacate (DOS) and DMSO aerosols using laser particle counters and filter samples. The pad had an efficiency greater than 990% for 0.1 μm DMSO particles. Test results on the prototype carbon filter showed only 70% efficiency, instead of the 99.9% in small scale laboratory tests. Thus further work will be required to develop the prototype carbon filter. 7 refs., 18 figs., 10 tabs

  13. Development of an air cleaning system for dissolving high explosives from nuclear warheads

    Energy Technology Data Exchange (ETDEWEB)

    Bergman, W.; Wilson, K.; Staggs, K.; Wapman, D. [Lawrence Livermore National Lab., CA (United States)

    1997-08-01

    The Department of Energy (DOE) has a major effort underway in dismantling nuclear weapons. In support of this effort we have been developing a workstation for removing the high explosive (HE) from nuclear warheads using hot sprays of dimethyl sulfoxide (DMSO) solvent to dissolve the HE. An important component of the workstation is the air cleaning system that is used to contain DMSO aerosols and vapor and radioactive aerosols. The air cleaning system consists of a condenser to liquefy the hot DMSO vapor, a demister pad to remove most of the DMSO aerosols, a high efficiency particulate air (HEPA) filter to remove the remaining aerosols, an activated carbon filter to remove the DMSO vapor, and a final HEPA filter to meet the redundancy requirement for HEPA filters in radioactive applications. The demister pad is a 4{double_prime} thick mat of glass and steel fibers and was selected after conducting screening tests on promising candidates. We also conducted screening tests on various activated carbons and found that all had a similar performance. The carbon breakthrough curves were fitted to a modified Wheeler`s equation and gave excellent predictions for the effect of different flow rates. After all of the components were assembled, we ran a series of performance tests on the components and system to determine the particle capture efficiency as a function of size for dioctyl sebacate (DOS) and DMSO aerosols using laser particle counters and filter samples. The pad had an efficiency greater than 990% for 0.1 {mu}m DMSO particles. Test results on the prototype carbon filter showed only 70% efficiency, instead of the 99.9% in small scale laboratory tests. Thus further work will be required to develop the prototype carbon filter. 7 refs., 18 figs., 10 tabs.

  14. Atmospheric trace gas measurements with a new clean air sampling system

    International Nuclear Information System (INIS)

    The development of a new clean air sampling system for the Department of Energy's WB-57F aircraft has allowed the analysis of CCl3F (Fluorocarbon-11), CCl2F2 (Fluorocarbon-12), CHClF2 (Fluorocarbon-22), C2Cl3F3 (Fluorocarbon-113), CH4, CO, CO2, N2O, CH3Cl, CCl4, CH3CCl3, OCS and SF6 in tropospheric and stratospheric samples. Samples collected during the interception of the plume from the eruption of Mount St. Helens indicate that OCS was injected into the stratosphere during the eruption. A large CO2 gradient was found at 19.2 km on this flight

  15. Plants + soil/wetland microbes: Food crop systems that also clean air and water

    Science.gov (United States)

    Nelson, Mark; Wolverton, B. C.

    2011-02-01

    The limitations that will govern bioregenerative life support applications in space, especially volume and weight, make multi-purpose systems advantageous. This paper outlines two systems which utilize plants and associated microbial communities of root or growth medium to both produce food crops and clean air and water. Underlying these approaches are the large numbers and metabolic diversity of microbes associated with roots and found in either soil or other suitable growth media. Biogeochemical cycles have microbial links and the ability of microbes to metabolize virtually all trace gases, whether of technogenic or biogenic origin, has long been established. Wetland plants and the rootzone microbes of wetland soils/media also been extensively researched for their ability to purify wastewaters of a great number of potential water pollutants, from nutrients like N and P, to heavy metals and a range of complex industrial pollutants. There is a growing body of research on the ability of higher plants to purify air and water. Associated benefits of these approaches is that by utilizing natural ecological processes, the cleansing of air and water can be done with little or no energy inputs. Soil and rootzone microorganisms respond to changing pollutant types by an increase of the types of organisms with the capacity to use these compounds. Thus living systems have an adaptive capacity as long as the starting populations are sufficiently diverse. Tightly sealed environments, from office buildings to spacecraft, can have hundreds or even thousands of potential air pollutants, depending on the materials and equipment enclosed. Human waste products carry a plethora of microbes which are readily used in the process of converting its organic load to forms that can be utilized by green plants. Having endogenous means of responding to changing air and water quality conditions represents safety factors as these systems operate without the need for human intervention. We review

  16. A method and device for cleaning air

    DEFF Research Database (Denmark)

    2009-01-01

    The present invention relates to a method and device for cleaning pollution from air wherin the air to be cleaned is subjected to a sequence of physical and chemical treatments.......The present invention relates to a method and device for cleaning pollution from air wherin the air to be cleaned is subjected to a sequence of physical and chemical treatments....

  17. Plants + microbes: Innovative food crop systems that also clean air and water

    Science.gov (United States)

    Nelson, Mark; Wolverton, B. C.

    The limitations that will govern bioregenerative life support applications in space, especially volume and weight, make multi-purpose systems advantageous. This paper outlines two systems which utilize plants and associated microbial communities of root or growth medium to both produce food crops and clean air and water. Underlying these approaches are the large numbers and metabolic diversity of microbes associated with roots and found in either soil or other suitable growth media. It is known that most biogeochemical cycles have a microbial link, and the ability of microbes to metabolize virtually all trace gases, whether of technogenic or biogenic origin, have long been established. Wetland plants and soil/media also been extensively researched for their ability to purify wastewaters of all kinds of potential water pollutants, from nutrients like N and P, to heavy metals and a range of complex industrial pollutants. There is a growing body of research on the ability of higher plants to purify air and water. Associated benefits of these approaches is that by utilizing natural ecological processes, the cleansing of air and water can be done with little or no energy inputs. Soil and root microorganisms respond to changing pollutant types by an increase of the types of organisms with the capacity to use these compounds. Thus living systems have an extraordinary adaptive capacity as long as the starting populations are sufficiently diverse. It is known that tightly sealed environments, from office buildings to spacecraft, can have hundreds or even thousands of potential air pollutants, depending on the materials and machines enclosed. Human waste products carry a plethora of microbes can are readily used in the process of converting its organic load to forms that can be utilized by green plants. Having endogenous means of responding to changing air and water quality conditions represents safety factors which operate without the need for human direction. We will

  18. Containment air cleaning for LMFBRs

    International Nuclear Information System (INIS)

    A variety of air cleaning concepts was evaluated for potential use in future sodium-cooled breeder reactors. A 3-stage aqueous scrubber system was selected for large-scale demonstration testing under conditions similar to those postulated for containment venting and purging during reactor melt-through accidents. Two tests were performed in the Containment Systems Test Facility using a quench tank, a jet venturi scrubber and a high efficiency fibrous scrubber in series. The results of two tests with Na202 and Na0H aerosol and NaI vapor are presented showing >99.9% removal of Na202 and Na0H and >99.7% for NaI

  19. Clean Air and Water

    Centers for Disease Control (CDC) Podcasts

    2007-04-10

    The air we breathe and the water we drink are both vital components of our health. Nevertheless, bacteria, pollutants, and other contaminates can alter life-giving air and water into health-threatening hazards. Learn about how scientists at the Centers for Disease Control and Prevention work to protect the public from air and water-related health risks.  Created: 4/10/2007 by CDC National Center for Environmental Health.   Date Released: 4/13/2007.

  20. Air Cleaning at the USAEC Y-12 Plant

    International Nuclear Information System (INIS)

    This paper describes some of the air-cleaning requirements of production, research, development and biological facilities in the Y-12 area. Problems and their solutions in hazardous-material containment, air cleaning, contamination control, and air pollution control are enumerated. Bioclean and laminar-flow clean rooms, germ-free supply air systems, exhaust systems for handling toxic and radioactive materials, virus containment and exhaust facilities are described. The Plant's practices regarding air cleaning are discussed including standardization of specifications for high-efficiency particulate air filters and mounting frames, DOP testing of air filter systems, and the replacement of sub-standard filter installations. (author)

  1. Efficiency Testing of the Air Cleaning System for a High Temperature Reactor

    International Nuclear Information System (INIS)

    The Los Alamos Ultra High Temperature Reactor Experiment (UHTREX) utilizes a helium-cooled, graphite-moderated reactor, employing refractory fuel elements. Under accident conditions, the effluent that may be released from this reactor requires an air-cleaning system capable of reducing radioactive gas and particulate contaminants to safe levels. Dioctyl phthalate and iodine-131 were used as test aerosols for the HEPA and activated carbon filters, respectively. Methods of aerosol generation and test procedures are detailed for the preinstallation tests of the carbon and in-place testing of the carbon and HEPA filters. The importance of visual inspection of the HEPA filters prior to installation and supervision of filter installation is discussed. In-place tests indicated desirable design changes which would (1) simplify in-place testing procedures, (2) expedite installation and future changing of the filters, and (3) ensure operation of a more efficient system. Problems encountered during in-place testing, recommendations for the design of similar systems, and acceptance criteria used at LASL are discussed. (author)

  2. Senate passes clean air bill

    Science.gov (United States)

    In an 89 to 11 vote the Senate passed a clean air bill aimed at reducing pollution by the turn of the century by imposing tougher controls on American industry. The bill is the first revision of the Clean Air Act of 1970 in 13 years and calls for new limits on auto pollution to clean up smog in most U.S. cities, decreasing by half emissions by power plants that cause acid rain to protect the ecology, and increasing technological controls on factories to protect against cancer-causing and toxic substances. The bill will add about $20 billion per year to the estimated $33 billion cost of complying with current pollution laws.

  3. Effects of welding fumes on nuclear air cleaning system carbon adsorber banks

    International Nuclear Information System (INIS)

    Standard Technical Specifications for nuclear air cleaning systems include requirements for surveillance tests following fire, painting, or chemical release in areas communicating with the affected system. To conservatively implement this requirement, many plants categorize welding as a chemical release process, and institute controls to ensure that welding fumes do not interact with carbon adsorbers in a filter system. After reviewing research data that indicated welding had a minimal impact on adsorber iodine removal efficiency, further testing was performed with the goal of establishing a welding threshold. It was anticipated that some quantity of weld electrodes could be determined that had a corresponding detrimental impact on iodine removal efficiency for the exposed adsorber. This value could be used to determine a conservative sampling schedule that would allow the station to perform laboratory testing to ensure system degradation did not occur without a full battery of surveillance tests. A series of tests was designed to demonstrate carbon efficiency versus cumulative welding fume exposure. Three series of tests were performed, one for each of three different types of commonly used weld electrodes. Carbon sampling was performed at baseline conditions, and every five pounds of electrode thereafter. Two different laboratory tests were performed for each sample; one in accordance with ASTM 3803/1989 at 95% relative humidity and 30 degrees C, and another using the less rigorous conditions of 70% relative humidity and 80 degrees C. Review of the test data for all three types of electrodes failed to show a significant correlation between carbon efficiency degradation and welding fume exposure. Accordingly, welding is no longer categorized as a 'chemical release process' at McGuire Nuclear Station, and limits on welding fume interaction with ventilation systems have been eliminated. 4 refs., 3 figs., 1 tab

  4. Effects of welding fumes on nuclear air cleaning system carbon adsorber banks

    Energy Technology Data Exchange (ETDEWEB)

    Roberson, P.W. [Duke Power Company, Huntersville, NC (United States)

    1997-08-01

    Standard Technical Specifications for nuclear air cleaning systems include requirements for surveillance tests following fire, painting, or chemical release in areas communicating with the affected system. To conservatively implement this requirement, many plants categorize welding as a chemical release process, and institute controls to ensure that welding fumes do not interact with carbon adsorbers in a filter system. After reviewing research data that indicated welding had a minimal impact on adsorber iodine removal efficiency, further testing was performed with the goal of establishing a welding threshold. It was anticipated that some quantity of weld electrodes could be determined that had a corresponding detrimental impact on iodine removal efficiency for the exposed adsorber. This value could be used to determine a conservative sampling schedule that would allow the station to perform laboratory testing to ensure system degradation did not occur without a full battery of surveillance tests. A series of tests was designed to demonstrate carbon efficiency versus cumulative welding fume exposure. Three series of tests were performed, one for each of three different types of commonly used weld electrodes. Carbon sampling was performed at baseline conditions, and every five pounds of electrode thereafter. Two different laboratory tests were performed for each sample; one in accordance with ASTM 3803/1989 at 95% relative humidity and 30 degrees C, and another using the less rigorous conditions of 70% relative humidity and 80 degrees C. Review of the test data for all three types of electrodes failed to show a significant correlation between carbon efficiency degradation and welding fume exposure. Accordingly, welding is no longer categorized as a `chemical release process` at McGuire Nuclear Station, and limits on welding fume interaction with ventilation systems have been eliminated. 4 refs., 3 figs., 1 tab.

  5. Design of Small Test Facility for Engineering Safety Feature Air Clean-up System

    International Nuclear Information System (INIS)

    USNRC (United State Nuclear Regulatory Committee) issued Regulatory Guide 1.52, Rev. 3 (RG. 1.52 Rev.3) in 2006, and the major changes of Rev. 3 with respect to Rev.2 are[1]: 1) the test time was reduced from 10 hours to 15 minutes, 2) instead of DOP (Dioctyl Phthalate) , an alternative challenge agent for the In-place aerosol leak tests of the HEPA (high-efficiency particulate air) filters is also viable, and 3) extension of the test period from 18 months to 24 months for the In-place aerosol leak tests. It is clear that the revised guideline can provide benefits for the licensees without degrading safety standards, and Korean nuclear industry initiated a project to accumulate the background information of these changes and examine if similar changes can be taken places in domestic plants since it is believed that the revised guidance can be applicable if sufficient justifications are provided. As a part of these activities manufacturing the small test facility and testing the performance of ESF ACS (Engineering Safety Feature Air Clean-up System) is required. This paper deals with the design principle and actual design methodology. At first the theoretical review on the filtration mechanism was carried out and then the substantial strategy for test facility design was setup. Actual verification for the goodness of test facility design was conducted using CFD (Computational Fluid Dynamic) analysis. These CFD analyses provide the flow field information both the plant ESF ACS and test facility, and these velocity fields are key parameters for the filtration efficiency

  6. Clean Air Act. Revision 5

    Energy Technology Data Exchange (ETDEWEB)

    1994-02-15

    This Reference Book contains a current copy of the Clean Air Act, as amended, and those regulations that implement the statute and appear to be most relevant to DOE activities. The document is provided to DOE and contractor staff for informational purposes only and should not be interpreted as legal guidance. This Reference Book has been completely revised and is current through February 15, 1994.

  7. Air cleaning using regenerative silica gel wheel

    DEFF Research Database (Denmark)

    Fang, Lei

    2011-01-01

    This paper discussed the necessity of indoor air cleaning and the state of the art information on gas-phase air cleaning technology. The performance and problems of oxidation and sorption air cleaning technology were summarized and analysed based on the literature studies. Eventually, based on an...

  8. Cleaning verification by air/water impingement

    Science.gov (United States)

    Jones, Lisa L.; Littlefield, Maria D.; Melton, Gregory S.; Caimi, Raoul E. B.; Thaxton, Eric A.

    1995-01-01

    This paper will discuss how the Kennedy Space Center intends to perform precision cleaning verification by Air/Water Impingement in lieu of chlorofluorocarbon-113 gravimetric nonvolatile residue analysis (NVR). Test results will be given that demonstrate the effectiveness of the Air/Water system. A brief discussion of the Total Carbon method via the use of a high temperature combustion analyzer will also be given. The necessary equipment for impingement will be shown along with other possible applications of this technology.

  9. Experimental study on energy performance of clean air heat pump

    DEFF Research Database (Denmark)

    Fang, Lei; Nie, Jinzhe; Olesen, Bjarne W.

    2014-01-01

    to investigate its energy performance. Energy consumption of the prototype of CAHP was measured in laboratory at different climate conditions including mild-cold, mildhot and extremely hot and humid climates. The energy saving potential of the clean air heat pump compared to a conventional ventilation and air......An innovative clean air heat pump (CAHP) was designed and developed based on the air purification capacity of regenerative silica gel rotor. The clean air heat pump integrated air purification, dehumidification and cooling in one unit. A prototype of the clean air heat pump was developed......-conditioning system was calculated. The experimental results showed that the clean air heat pump saved substantial amount of energy compared to the conventional system. For example, the CAHP can save up to 59% of electricity in Copenhagen, up to 40% of electricity in Milan and up to 30% of electricity in Colombo...

  10. Clean Air Status and Trends Network (CASTNET)

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Clean Air Status and Trends Network (CASTNET) is a national air quality monitoring network designed to provide data to assess trends in air quality, atmospheric...

  11. Development of an emergency air-cleaning system for liquid-metal reactors

    International Nuclear Information System (INIS)

    A novel air cleaning concept has been developed for potential use in venting future commercial liquid metal fast breeder reactor containment buildings in the unlikely event of postulated core disruptive accidents. The passive concept consists of a submerged gravel bed to collect the bulk of particulate contaminates carried by the vented gas. A fibrous scrubber could be combined with the submerged gravel scrubber to enhance collection efficiencies for the smaller sized particles. The submerged gravel scrubber is unique in that water flow through the packed bed is induced by the gas flow, eliminating the need for an active liquid pump. In addition, design gas velocities through the packed bed are 10 to 20 times higher than for a conventional sand bed filter

  12. Air pollution and air cleaning equipment in buildings

    OpenAIRE

    Evdokimova, Ekaterina

    2011-01-01

    The subject of this thesis work is air pollution and air cleaners in building. Clean air has big significance for human health because different pollutions can cause allergy and disease. The quality of indoor air affects health and effective working. The aim of this thesis is to present methods and devices for cleaning the air.

  13. Seismic simulation and functional performance evaluation of a safety related, seismic category I control room emergency air cleaning system

    International Nuclear Information System (INIS)

    Under a nuclear contract MSA was required to design, manufacture, seismically test and functionally test a complete Safety Related, Seismic Category I, Control Room Emergency Air Cleaning System before shipment to the Yankee Atomic Electric Company, Yankee Nuclear Station in Rowe, Massachusetts. The installation of this system was required to satisfy the NRC requirements of NUREG-0737, Section III, D.3.4, ''Control Room Habitability''. The filter system tested was approximately 3 ft. wide by 8 ft. high by 18 ft. long and weighed an estimated 8300 pounds. It had a design flow rate of 3000 SCFM and contained four stages of filtration - prefilters, upstream and downstream HEPA filters and Type II sideload charcoal adsorber cells. The filter train design followed the guidelines set forth by ANSI/ASME N509-1980. Seismic Category I Qualification Testing consisted of resonance search testing and triaxial random multifrequency testing. In addition to ANSI/ASME N510-1980 testing, triaxial response accelerometers were placed at specific locations on designated prefilters, HEPA filters, charcoal adsorbers and test canisters along with accelerometers at the corresponding filter seal face locations. The purpose of this test was to demonstrate the integrity of the filters, filter seals, and monitor seismic response levels which is directly related to the system's ability to function during a seismic occurrence. The Control Room Emergency Air Cleaning System demonstrated the ability to withstand the maximum postulated earthquake for the plant site by remaining structurally sound and functional

  14. Aviation, Carbon, and the Clean Air Act

    OpenAIRE

    Richardson, Nathan

    2012-01-01

    This paper explores the policy options available to the United States for regulating greenhouse gas emissions from aircraft under existing law: the Clean Air Act (CAA). Europe has unilaterally and controversially moved to include aviation emissions in its Emissions Trading System. The United States can, however, allow its airlines to escape this requirement by imposing “equivalent” regulation. U.S. aviation emissions rules could also have significant environmental benefits and would limit dom...

  15. Chemistry in Clean Marine Air

    Science.gov (United States)

    Lundja, J. O.; Tshiala, M.

    2009-05-01

    Model-measurement comparisons of HOx in extremely clean air ([NO]Measurements were made during the second Southern Ocean Photochemistry Experiment (SOAPEX-2), The free-radical chemistry was studied using a zero-dimensional box-model based upon the Master Chemical Mechanism (MCM). Two versions of the model were used, with different levels of chemical complexity, to explore the role of hydrocarbons upon free-radical budgets under very clean conditions. The "detailed" model was constrained to measurements of CO, CH4 and 17 NMHCs, while the "simple" model contained only the CO and CH4 oxidation mechanisms, together with inorganic chemistry. The OH and HO2 (HOx) concentrations predicted by the two models agreed to within 5-10%. The model results were compared with the HOx concentrations measured by the FAGE (Fluorescence Assay by Gas Expansion) technique during four days of clean Southern Ocean marine boundary layer (MBL) air. The models overestimated OH concentrations by about 10% on two days and about 20% on the other two days. HO2 concentrations were measured during two of these days and the models overestimated the measured concentrations by about 40%. Better agreement with measured HO2 was observed by using data from several MBL aerosol measurements to estimate the aerosol surface area and by increasing the HO2 uptake coefficient to unity. This reduced the modelled HO2 overestimate by ~40%, with little effect on OH, because of the poor HO2 to OH conversion at the low ambient NOx concentrations. Local sensitivity analysis and Morris One-At-A-Time analysis were performed on the "simple" model, and showed the importance of reliable measurements of j(O1D) and [HCHO] and of the kinetic parameters that determine the efficiency of O(1D) to OH and HCHO to HO2 conversion. A 2σ standard deviation of 30-40% for OH and 25-30% for HO2 was estimated for the model calculations using a Monte Carlo technique coupled with Latin Hypercube Sampling (LHS).

  16. Effects of indoor air purification by an air cleaning system (Koala technology) on semen parameters in male factor infertility: results of a pilot study.

    Science.gov (United States)

    Paradisi, R; Vanella, S; Barzanti, R; Cani, C; Battaglia, C; Seracchioli, R; Venturoli, S

    2009-06-01

    A number of studies indicated a clear decline in semen quality in the past 30-50 years and there is accumulating evidence that this decline might result from exposure to high levels of air pollution. To examine the impact of environment on male reproductive ability, we undertook for the first time a pilot study on semen quality of infertile men exposed to purification of indoor air. Ten subjects with a history of unexplained male infertility and poor semen quality were exposed for at least 1 year to a cleaning indoor air system (Koala technology). The key feature of this air purifier is the unique innovative multiple filtering system. The treatment of total purification of indoor air showed neither improvements in semen parameters nor variation in reproductive hormones (P = N.S.), but induced an evident increase (P indoor air does not seem enough to improve semen quality, although the increase in leucocytic concentrations could indicate an activation of the role of immunosurveillance in a purified indoor air environment. PMID:19400850

  17. RESULTS OF A PILOT FIELD STUDY TO EVALUATE THE EFFECTIVENESS OF CLEANING RESIDENTIAL HEATING AND AIR-CONDITIONING SYSTEMS AND THE IMPACT ON INDOOR AIR QUALITY AND SYSTEM PERFORMANCE

    Science.gov (United States)

    The report discusses and gives results of a pilot field study to evaluate the effectiveness of air duct cleaning (ADC) as a source removal technique in residential heating and air-conditioning (HAC) systems and its impact on airborne particle, fiber, and bioaerosol concentrations...

  18. 16th DOE nuclear air cleaning conference: proceedings

    International Nuclear Information System (INIS)

    Major topics discussed during the Sixteenth DOE Nuclear Air Cleaning Conference were: waste treatment, including volume reduction and storage; system and component response to stress and accident conditions; Three Mile Island accident; iodine adsorption; treatment and storage of noble gas: treatment of offgases from chemical processing; aerosol; behavior; containment venting; laboratory and in-place filter-testing methods; and particulate filtration. Volume I of the Proceedings has 49 papers from the following sessions; HEPA filter test methods; noble gas separation; air cleaning system design; containment venting; iodine adsorption; reprocessing offgas cleaning; critical review; filtration; filter testing; and aerosols. Volume II contains 44 papers from the sessions on: nuclear waste treatment; critical review; noble gas treatment; carbon-14 and tritium; air cleaning system response to stress; nuclear standards and safety; round table; open end; and air cleaning technology at Three Mile Island. Abstracts are provided for all of these papers

  19. 16th DOE nuclear air cleaning conference: proceedings

    International Nuclear Information System (INIS)

    Major topics discussed during the Sixteenth DOE Nuclear Air Cleaning Conference were: waste treatment, including volume reduction and storage; system and component response to stress and accident conditions; Three Mile Island accident; iodine adsorption; treatment and storage of noble gas; treatment of offgases from chemical processing; aerosol behavior; containment venting; laboratory and in-place filter-testing methods; and particulate filtration. Volume I of the Proceedings has 49 papers from the following sessions: HEPA filter test methods; noble gas separation; air cleaning system design; containment venting; iodine adsorption; reprocessing offgas cleaning; critical review; filtration, filter testing, and aerosols. Volume II contains 44 papers from the sessions on: nuclear waste treatment; critical review; noble gas treatment; carbon-14 and tritium; air cleaning system response to stress; nuclear standards and safety; round table; open end; and air cleaning technology at Three Mile Island. Abstracts are provided for all of these papers

  20. The impact of the 1990 Clean Air Act Amendments on biofuels usage and waste-to-energy systems

    International Nuclear Information System (INIS)

    The 1990 Clean Air Act Amendments represent the most sweeping revisions to the Act to date and the impact of these changes will alter the environmental framework within which waste-to-energy facilities currently operate. This paper discusses the most important aspects of the Amendments as they affect waste-to-energy systems including new major source provisions, siting in non-attainment areas, Title III treatment of municipal waste combustion, special incentive allowances under Title IV for use of renewable resources, alternative fuel usage, and the harsh enforcement regime. The paper also will provide conference attendees with guidance on how the new Act will change the way facilities structure their deals including prospects for creative financing, the market for allowances, retrofitting potential fuel-switching options, impact on construction contracts and costs to the industry

  1. Clean Air Markets - Quick Facts and Trends

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Quick Facts and Trends module is part of a suite of Clean Air Markets-related tools that are accessible at http://camddataandmaps.epa.gov/gdm/index.cfm. The...

  2. Clean Air Markets - Compliance Query Wizard

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Compliance Query Wizard is part of a suite of Clean Air Markets-related tools that are accessible at http://ampd.epa.gov/ampd/. The Compliance module provides...

  3. Utility view of the source term and air cleaning

    International Nuclear Information System (INIS)

    The utility view of the source term and air cleaning is discussed. The source term is made up of: (1) noble gases, which there has been a tendency to ignore in the past because it was thought there was nothing that could be done with them anyway, (2) the halogens, which have been dealt with in Air Cleaning Conferences in the past in terms of charcoal and other systems for removing them, and (3) the solid components of the source term which particulate filters are designed to handle. Air cleaning systems consist of filters, adsorbers, containment sprays, suppression pools in boiling water reactors and ice beds in ice condenser-equipped plants. The feasibility and cost of air cleaning systems are discussed

  4. Ductless personalized ventilation with local air cleaning

    DEFF Research Database (Denmark)

    Dalewski, Mariusz; Vesely, Michal; Melikov, Arsen Krikor

    2012-01-01

    An experiment with 28 human subjects was performed to examine effects of using a local air cleaning device combined with ductless personalized ventilation (DPV) on perceived air quality. Experiments were performed in a test room with displacement ventilation. The DPV at one of two desks was...... equipped with an activated carbon filter installed at the air intake, while the DPV at the second desk was without such a filter. The air temperature in the occupied zone (1.1 m above the floor) was 29 °C. The pollution load in the room was simulated by PVC floor covering. The subjects assessed...... acceptability of air quality, odour intensity and air freshness at both desks in random order. Lower odour intensity and higher air freshness was reported at the desk with DPV with the activated carbon filter. The results suggest that using local air cleaning devices integrated with DPV may improve perceived...

  5. Odor and the Clean Air Act

    International Nuclear Information System (INIS)

    The case described in this paper involves the interpretation of language contained in the Texas Clean Air Act Texas Health and Safety Code Ann. Sections 382.001-382.141. The State of Texas, on behalf of the Texas Air Control Board, brought suit in the District Court of Erath County, Texas against the F/R Cattle Company, Inc., alleging that, because of odors emanating from the company's cattle feeding facility, the company was violating the Clean Air Act. The Board is granted the power and duty to administer the Clean Air Act and is directed to accomplish the purposes of the Act through the control of air contaminants by all practical and economically feasible methods. Described here is the evidence presented at and proceedings of the trial

  6. HEPA filters of high structural strength for nuclear air cleaning systems

    International Nuclear Information System (INIS)

    HEPA-filter media, though having excellent particle-removal efficiencies, remain characterized as rather brittle, fragile, and weak materials. As a result, undesired structural damage, followed by significant losses in filtration efficiency, can easily occur in handling, transport, and even normal operation of filter units. In recent years, extensive investigations into the structural limits of HEPA filters in dry air and under extended exposure to high-humidity airflow have been carried out. In the course of this work, the failure modes and the underlying failure mechanisms were thoroughly studied. On the basis of the information obtained, considerable improvements in the structural strength of HEPA filters could be achieved. As verified by removal efficiency tests, differential pressures up to 56 kPA in dry air and 15 kPA after extended operation under fog conditions were proved to be sustainable without mechanical damage to the filter medium

  7. New Air Cleaning Strategies for Reduced Commercial Building Ventilation Energy

    Energy Technology Data Exchange (ETDEWEB)

    Sidheswaran, Meera; Destaillats, Hugo; Sullivan, Douglas P.; Fisk, William J.

    2010-10-27

    Approximately ten percent of the energy consumed in U.S. commercial buildings is used by HVAC systems to condition outdoor ventilation air. Reducing ventilation rates would be a simple and broadly-applicable energy retrofit option, if practical counter measures were available that maintained acceptable concentrations of indoor-generated air pollutants. The two general categories of countermeasures are: 1) indoor pollutant source control, and 2) air cleaning. Although pollutant source control should be used to the degree possible, source control is complicated by the large number and changing nature of indoor pollutant sources. Particle air cleaning is already routinely applied in commercial buildings. Previous calculations indicate that particle filtration consumes only 10percent to 25percent of the energy that would otherwise be required to achieve an equivalent amount of particle removal with ventilation. If cost-effective air cleaning technologies for volatile organic compounds (VOCs) were also available, outdoor air ventilation rates could be reduced substantially and broadly in the commercial building stock to save energy. The research carried out in this project focuses on developing novel VOC air cleaning technologies needed to enable energy-saving reductions in ventilation rates. The minimum required VOC removal efficiency to counteract a 50percent reduction in ventilation rate for air cleaning systems installed in the HVAC supply airstream is modest (generally 20percent or less).

  8. Source terms in relation to air cleaning

    International Nuclear Information System (INIS)

    There are two sets of source terms for consideration in air cleaning, those for routine releases and those for accident releases. With about 1000 reactor years of commercial operating experience in the US done, there is an excellent data base for routine and expected transient releases. Specifications for air cleaning can be based on this body of experience with confidence. Specifications for air cleaning in accident situations is another matter. Recent investigations of severe accident behavior are offering a new basis for source terms and air cleaning specifications. Reports by many experts in the field describe an accident environment notably different from previous models. It is an atmosphere heavy with aerosols, both radioactive and inert. Temperatures are sometimes very high; radioiodine is typically in the form of cesium iodide aerosol particles; other nuclides, such as tellurium, are also important aerosols. Some of the present air cleaning requirements may be very important in light of these new accident behavior models. Others may be wasteful or even counterproductive. The use of the new data on accident behavior models to reevaluate requirements promptly is discussed

  9. 76 FR 40728 - Clean Air Act Advisory Committee (CAAAC); Request for Nominations for 2011 Clean Air Excellence...

    Science.gov (United States)

    2011-07-11

    ... AGENCY Clean Air Act Advisory Committee (CAAAC); Request for Nominations for 2011 Clean Air Excellence Awards Program AGENCY: Environmental Protection Agency (EPA). ACTION: Request for nominations for Clean Air Excellence Awards. ] SUMMARY: EPA established the Clean Air Excellence Awards Program in...

  10. Clean Air Act compliance issues/panel

    International Nuclear Information System (INIS)

    This morning, four panelists will discuss the birth of the free market allowance trading system, how it was formed, when it was formed, how it was sold, how allowance trading has worked, how it is expected to work, and how utilities are planning based on allowance trading. We will also hear from a utility commissioner who will make some of the final decisions on cost recovery. So we will have various perspectives today on allowance trading. Many of you are here to learn more about how to comply with the Clean Air Act Amendments of 1990. Allowance trading is the cornerstone of the entire Title 4, the acid deposition title of the amendments, in which SO2 emission allowances are a tradeable right. Following the four presentations, we will entertain questions to the four participants from the audience

  11. Development of a personal computer code for fire protection analysis of DOE facility air-cleaning systems

    International Nuclear Information System (INIS)

    The United States Department of Energy (DOE) has sponsored development of a computer code to aid analysts performing fire hazards analyses for DOE facilities. The code selected for this application was the FIRAC code developed by the Los Alamos National Laboratory for the Nuclear Regulatory Commission. The original code has been modified by the Westinghouse-Hanford Company. The FIRAC code simulates fire accidents in nuclear facilities and predicts effects of a hypothetical fire within a compartment and its effect throughout the rest of the facility, particularly the air-cleaning systems. The FIRAC code was designed to run on Cray supercomputers. The input format is difficult to use. For this code to be useful to the DOE fire protection community, it had to be converted to run on an IBM PC and couple with a menu-driven pre-processor that would make preparation of the input easy to use for fire protection engineers. In addition, a graphical display of the analysis results was required. In this paper the authors describe the pre-processor, the PC version of FIRAC, and the post-processor graphics package. In the presentation, a demonstration of how to set up a problem and use the code is made. 4 figs

  12. Electricity competition and clean air

    International Nuclear Information System (INIS)

    The government of Ontario plans to establish a competitive market for the generation and sale of electricity by the year 2000, at which time Ontario Hydro will lose its monopoly. The government's rationale for moving to a competitive electricity market and the details of why this move could lead to a significant increase in air pollution was discussed. An overview of the health and environmental effects of electricity related air pollution was presented and the current national and provincial air quality objectives were outlined. The government of Ontario has promised that in implementing a competitive electricity market it will ensure that the province's environmental protection record is maintained and improved. It was suggested that in order to fulfill this commitment, new environmental regulations should be established to ensure that Ontario's total electricity-related emissions will decline when competition begins. Currently, air pollution from coal-fired power generating stations causes some of Ontario's most challenging health and environmental problems. Coal-fired generation stations are also major contributors to the build-up of greenhouse gases in the atmosphere. 74 refs., 2 tabs., 2 figs

  13. Ductless personalized ventilation with local air cleaning

    OpenAIRE

    Dalewski, Mariusz; Vesely, Michal; Melikov, Arsen Krikor

    2012-01-01

    An experiment with 28 human subjects was performed to examine effects of using a local air cleaning device combined with ductless personalized ventilation (DPV) on perceived air quality. Experiments were performed in a test room with displacement ventilation. The DPV at one of two desks was equipped with an activated carbon filter installed at the air intake, while the DPV at the second desk was without such a filter. The air temperature in the occupied zone (1.1 m above the floor) was 29 °C....

  14. Results of Inspection and Cleaning of Two Radionuclide Air-Sampling Systems Based on the Requirements of ANSI/HPS N13.1-1999

    International Nuclear Information System (INIS)

    The Pacific Northwest National Laboratory (PNNL) conducted inspection and cleaning activities at two radionuclide air-sampling systems that continuously monitor radioactive air emissions from research and development (RandD) facilities. The inspection and cleaning was performed to evaluate effective methods and potential cost impacts of maintenance requirements in the revised American National Standard Institute (ANSI) standard Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stacks and Ducts of Nuclear Facilities (ANSI/HPS N13.1-1999). The standard requires at least annual inspections of sampling systems followed by cleaning if deposits are visible. During 2001 and 2002, inspections were performed leaving the sampling systems in place and inserting videoscope cables into different access points to allow viewing of the inside and outside of sampling manifolds and transport lines. Cleaning was performed on one of the systems by disconnecting and extracting the sampling manifold, then washing it with de-ionized water and scrub brushes. The wash water was analyzed for radioactivity and solids. Results of the inspection showed greater deposition in one of the systems than would be expected by a High Efficiency Particulate Air (HEPA) filtered exhaust stream; the second system was also downstream of HEPA filters and appeared much cleaner. The videoscope was a useful and cost-effective tool and provided a better view than could be obtained with the naked eye. However, because even small amounts of deposition were made visible with the videoscope, clarification is needed in defining when probe washing is merited, particularly in existing sampling systems whose design is not conducive to easy removal and cleaning

  15. Green Walls for Clean Air

    OpenAIRE

    Gölsdorf, Katrin; Müller, Hans; Collier, Marcus

    2013-01-01

    Can plants help to improve the air quality? People have often complained about Ivy on buildings, but research by Helix Pflanzen GmbH, a company that is specialised in the cultivation of ivy species and the development of green wall technology, is shedding new light on an old problem. Using a cultivated variety of ivy (Hedera helix 'Wörner'), experiments were carried out that illustrated the binding effect that this Ivy has on fine dust particles. This is particularly important in urban ...

  16. New Air Cleaning Strategies for Reduced Commercial Building Ventilation Energy

    OpenAIRE

    Sidheswaran, Meera

    2010-01-01

    Approximately ten percent of the energy consumed in U.S. commercial buildings is used by HVAC systems to condition outdoor ventilation air. Reducing ventilation rates would be a simple and broadly-applicable energy retrofit option, if practical counter measures were available that maintained acceptable concentrations of indoor-generated air pollutants. The two general categories of countermeasures are: 1) indoor pollutant source control, and 2) air cleaning. Although pollutant source contr...

  17. Ensuring clean air: Developing a clean air strategy for British Columbia

    International Nuclear Information System (INIS)

    In 1992, a clean air strategy will be developed to incorporate views of British Columbians on ways to meet goals related to air quality. A discussion paper is presented to provide information to those interested in participation in developing this strategy. The paper gives information on air quality issues important to the province, including local air quality, urban smog, ozone layer depletion, and global climate change. The views and concerns expressed by stakeholders who attended the Clean Air Conference in 1991 are summarized. The process used to develop the clean air strategy is outlined and some outcomes to be anticipated from the strategy are suggested, including policies and priorities for action to ensure clean air. Air pollutants of concern are total reduced sulfur, mainly from pulp mills and gas processing plants; smoke from wood burning; sulfur dioxide from pulp mills and gas plants; hydrogen fluoride from aluminum smelting; ground-level ozone in urban areas; and acid rain. Elements of a clean air strategy include a smoke management policy, management strategies for greenhouse gases and ozone smog, ozone layer protection measures, regional air quality management plans, and long-term planning efforts in energy use, transportation modes, community design, and land use. 12 refs., 14 figs., 2 tabs

  18. Cleanly: trashducation urban system

    DEFF Research Database (Denmark)

    Reif, Inbal; Alt, Florian; Ramos, Juan David Hincapie;

    exacerbated by a poor personal trash management culture. In this paper we present Cleanly, an urban trashducation system aimed at creating awareness of garbage production and management, which may serve as an educational plat-form in the urban environment. We report on data collected from an online survey......, which not only motivates our research but also provides useful information on reasons and possible solutions for trash problems....

  19. 75 FR 35025 - Clean Air Act Advisory Committee (CAAAC); Request for Nominations for 2010 Clean Air Excellence...

    Science.gov (United States)

    2010-06-21

    ... AGENCY Clean Air Act Advisory Committee (CAAAC); Request for Nominations for 2010 Clean Air Excellence... Air Act Advisory Committee (CAAAC) Web site at http://www.epa.gov/oar/caaac by clicking on Awards.... ] Dated: June 15, 2010. Patrick Childers, Designated Federal Official for Clean Air Act Advisory...

  20. Amine-based post-combustion CO2 capture in air-blown IGCC systems with cold and hot gas clean-up

    International Nuclear Information System (INIS)

    Highlights: • Hot fuel gas clean-up is a very favorable technology for IGCC concepts. • IGCC net efficiency reduces to 41.5% when realizing post-combustion CO2 capture. • Complex IGCC layouts are necessary if exhaust gas recirculation is realized. • IGCC performance does not significantly vary with exhaust gas recirculation. - Abstract: This paper focuses on the thermodynamic performance of air-blown IGCC systems with post-combustion CO2 capture by chemical absorption. Two IGCC technologies are investigated in order to evaluate two different strategies of coal-derived gas clean-up. After outlining the layouts of two power plants, the first with conventional cold gas clean-up and the second with hot gas clean-up, attention is paid to the CO2 capture station and to issues related to exhaust gas recirculation in combined cycles. The results highlight that significant improvements in IGCC performance are possible if hot coal-derived gas clean-up is realized before the syngas fuels the combustion turbine, so the energy cost of CO2 removal in an amine-based post-combustion mode is less strong. In particular, IGCC net efficiency as high as 41.5% is calculated, showing an interesting potential if compared to the one of IGCC systems with pre-combustion CO2 capture. Thermodynamic effects of exhaust gas recirculation are investigated as well, even though IGCC performance does not significantly vary against a more complicated plant layout

  1. The 1990 Clean Air Act amendments

    International Nuclear Information System (INIS)

    The impacts of the 1990 Clean Air Act Amendments on utilities are substantial, presenting a host of new technical challenges, introducing new business risks, changing costs of electric generation, creating new winners and losers, and calling for new organizational responses capable of dealing with the complexity and short time for decisions. The magnitude of costs and unknowns puts clean air compliance into a new league of energy issues, in which the decisions utilities must make are not simply technological or engineering economic choices, but rather are very complex business decisions with numerous stakeholders, pitfalls, and opportunities. This paper summarizes the key regulatory requirements of the CAAA, outlines compliance options and questions facing the utility industry, and addresses how utility strategic business decisions could be affected

  2. The Clean Air Act Amendments of 1990

    International Nuclear Information System (INIS)

    The natural gas liquids industry and specifically the gas processing business has not been rosy the last several years. processors have been faced with low NGL prices, high inventories and more regulations which have forced product margins to all time lows and have resulted in plant closings, mergers and a determined search for those processors that are left for ways to make ends meet until times get better. Whether a barometer for the future or merely a fluke in the economy, things got better in 1990. Last year represented a change for the positive in all the indicators characterizing the gas processing business. An early winter in 1989, propane distribution problems, overall increases in petrochemical demand for NGLs and the fear brought on by events in Kuwait all contributed to changes in the marketplace. For the gas processor, these events combined with relatively low natural gas prices to produce wider processing margins and a degree of prosperity. The biggest regulatory event in 1990 however was without a doubt the Clean Air Act Amendments. These sweeping changes to the 1970 Clean Air Act promise to affect the economy and public health well into the next century. The purpose of this paper is to examine first the major provisions of the Clean Air Act Amendments of 1990 and then relate those anticipated changes to the gas processing industry. As will be examined later, the Amendments will create both threats and opportunities for gas processors

  3. 40 CFR 61.152 - Air-cleaning.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 8 2010-07-01 2010-07-01 false Air-cleaning. 61.152 Section 61.152...-cleaning. (a) The owner or operator who uses air cleaning, as specified in §§ 61.142(a), 61.144(b)(2), 61... spun. (2) Properly install, use, operate, and maintain all air-cleaning equipment authorized by...

  4. Plants Clean Air and Water for Indoor Environments

    Science.gov (United States)

    2007-01-01

    Wolverton Environmental Services Inc., founded by longtime government environmental scientist B.C. "Bill" Wolverton, is an environmental consulting firm that gives customers access to the results of his decades of cutting-edge bioremediation research. Findings about how to use plants to improve indoor air quality have been published in dozens of NASA technical papers and in the book, "How to Grow Fresh Air: 50 Houseplants That Purify Your Home or Office." The book has now been translated into 12 languages and has been on the shelves of bookstores for nearly 10 years. A companion book, "Growing Clean Water: Nature's Solution to Water Pollution," explains how plants can clean waste water. Other discoveries include that the more air that is allowed to circulate through the roots of the plants, the more effective they are at cleaning polluted air; and that plants play a psychological role in welfare in that people recover from illness faster in the presence of plants. Wolverton Environmental is also working in partnership with Syracuse University, to engineer systems consisting of modular wicking filters tied into duct work and water supplies, essentially tying plant-based filters into heating, ventilation, and air conditioning (HVAC) systems. Also, the company has recently begun to assess the ability of the EcoPlanter to remove formaldehyde from interior environments. Wolverton Environmental is also in talks with designers of the new Stennis Visitor's Center, who are interested in using its designs for indoor air-quality filters

  5. Clean air strategy for Alberta: Report to the ministers

    International Nuclear Information System (INIS)

    As a response to continuing discussions on the impact of fossil fuels on global warming, acid deposition, and smog, a clean air strategy consultation program was announced by Alberta's Ministers of Energy and Environment to encourage public discussion on air emissions resulting from the production and use of energy. The consultation program had three objectives: to help identify and clarify the most important issues associated with energy production and use which need to be addressed in developing a clean air strategy; to outline practical and achievable actions which can be taken to reduce emissions; and to develop program and policy recommendations to the provincial government. The consultation program included workshops and regional sessions, as well as background research. The discussions, findings, and conclusions from the program are summarized. Several air quality management challenges were identified, including the need for a more comprehensive system for managing air quality; the priority of local air quality issues and problems; the need to address cumulative regional emissions and impacts; and scientific and economic uncertainties. A number of goals have been developed to address these challenges, such as implementation of a comprehensive air quality management system, identification of cost-effective energy conservation and efficiency opportunities, development of innovative and targeted solutions to manage cumulative emissions, and improvement of the gathering and application of scientific and technical knowledge regarding atmospheric processes and effects. A glossary of terms is included. 12 figs., 17 tabs

  6. Clean air with positive energy balance. Elisabeth hospital in Essen uses energy optimized air conditioning systems; Saubere Luft mit positiver Energiebilanz. Elisabeth-Krankenhaus in Essen nutzt energieoptimierte Lueftungsgeraete

    Energy Technology Data Exchange (ETDEWEB)

    Dunker, Ralf

    2009-02-15

    Thinking on a long-term basis, spontaneously acting - according to this slogan the Elizabeth hospital in Essen (Federal Republic of Germany) converts potentials of energy saving with the facility management. Parallel to the change of the endoscope department and the station Barbara with its 35 beds, the hospital had installed particularly energy-saving air conditioning systems which can be cleaned easily. A view behind the doors of the technology rooms.

  7. Proceedings of the 21st DOE/NRC Nuclear Air Cleaning Conference; Sessions 1--8

    Energy Technology Data Exchange (ETDEWEB)

    First, M.W. [ed.] [Harvard Univ., Boston, MA (United States). Harvard Air Cleaning Lab.

    1991-02-01

    Separate abstracts have been prepared for the papers presented at the meeting on nuclear facility air cleaning technology in the following specific areas of interest: air cleaning technologies for the management and disposal of radioactive wastes; Canadian waste management program; radiological health effects models for nuclear power plant accident consequence analysis; filter testing; US standard codes on nuclear air and gas treatment; European community nuclear codes and standards; chemical processing off-gas cleaning; incineration and vitrification; adsorbents; nuclear codes and standards; mathematical modeling techniques; filter technology; safety; containment system venting; and nuclear air cleaning programs around the world. (MB)

  8. Proceedings of the 21st DOE/NRC Nuclear Air Cleaning Conference

    International Nuclear Information System (INIS)

    Separate abstracts have been prepared for the papers presented at the meeting on nuclear facility air cleaning technology in the following specific areas of interest: air cleaning technologies for the management and disposal of radioactive wastes; Canadian waste management program; radiological health effects models for nuclear power plant accident consequence analysis; filter testing; US standard codes on nuclear air and gas treatment; European community nuclear codes and standards; chemical processing off-gas cleaning; incineration and vitrification; adsorbents; nuclear codes and standards; mathematical modeling techniques; filter technology; safety; containment system venting; and nuclear air cleaning programs around the world. (MB)

  9. Saving energy and improving IAQ through application of advanced air cleaning technologies

    Energy Technology Data Exchange (ETDEWEB)

    Fisk, W.J; Destaillats, H.; Sidheswaran, M.A.

    2011-03-01

    In the future, we may be able use air cleaning systems and reduce rates of ventilation (i.e., reduce rates of outdoor air supply) to save energy, with indoor air quality (IAQ) remaining constant or even improved. The opportunity is greatest for commercial buildings because they usually have a narrower range of indoor pollutant sources than homes. This article describes the types of air cleaning systems that will be needed in commercial buildings.

  10. Saving energy and improving IAQ through application of advanced air cleaning technologies

    OpenAIRE

    Fisk, W J

    2012-01-01

    In the future, we may be able use air cleaning systems and reduce rates of ventilation (i.e., reduce rates of outdoor air supply) to save energy, with indoor air quality (IAQ) remaining constant or even improved. The opportunity is greatest for commercial buildings because they usually have a narrower range of indoor pollutant sources than homes. This article describes the types of air cleaning systems that will be needed in commercial buildings.

  11. Energy Efficient Indoor VOC Air Cleaning with Activated Carbon Fiber (ACF) Filters

    OpenAIRE

    Sidheswaran, Meera

    2012-01-01

    This study explores the potential environmental and energy benefits of using activated carbon fiber (ACF) filters for air cleaning in HVAC systems. The parallel aims for the air cleaning system were to enable reduced indoor exposures to volatile organic compounds (VOCs) and to simultaneously allow reduced rates and energy consumption for outdoor-air ventilation. We evaluated the use of ACF media to adsorb VOCs from indoor air during repeated simulated 12-hour to 24-hour periods of occupancy. ...

  12. Nuclear air cleaning R and D programs in Canada

    International Nuclear Information System (INIS)

    All CANDU reactor generating stations are equipped with various gas treatment systems. The off-gas management system, the reactor ventilation system (or containment exhaust system), and the heavy water vapor recovery system reduce gaseous radioactive emissions during normal station operation whereas the emergency filtered air discharge system is designed for post-accident containment clean-up. The paper discusses the following research programs studying gaseous radionuclides in Canadian facilities: carbon-14 research and development program; tritium research and development program; iodine research and development program; aerosol research program; noble gases research and development program

  13. Proceedings of the 24. DOE/NRC nuclear air cleaning and treatment conference

    International Nuclear Information System (INIS)

    This report contains the papers presented at the 24th DOE/NRC Nuclear Air Cleaning and Treatment Conference and the associated discussions. Major topics are: (1) nuclear air cleaning issues, (2) waste management, (3) instrumentation and measurement, (4) testing air and gas cleaning systems, (5) progress and challenges in cleaning up Hanford, (6) international nuclear programs, (7) standardized test methods, (8) HVAC, (9) decommissioning, (10) computer modeling applications, (11) adsorption, (12) iodine treatment, (13) filters, and (14) codes and standards for filters and adsorbers. Selected papers have been indexed separately for inclusion in the Energy Science and Technology Database

  14. A pilot study of energy efficient air cleaning for ozone

    Energy Technology Data Exchange (ETDEWEB)

    Gundel, Lara A.; Sullivan, Douglas P.; Katsapov, Gregory Y.; Fisk, William J.

    2002-11-01

    A laboratory pilot study has been undertaken with the material that showed the most promise (high capacity and low pressure drop) based on the literature review and associated calculations. The best-performing air cleaner was a commercially available pleated filter that contained a thin layer of small activated carbon particles between two sheets of non-woven fibrous webbing. We will refer to this unit as the ''ozone filter'' although it is marketed for removal of volatile organic compounds (VOCs) from automobile passenger compartments. This pilot study strongly suggests that ozone air cleaning can be practical in commercial air handling systems; however, further tests are needed to assess air cleaner performance under a wider range of conditions.

  15. 75 FR 34673 - Approval of the Clean Air Act, Section 112(l), Authority for Hazardous Air Pollutants: Air...

    Science.gov (United States)

    2010-06-18

    ... AGENCY 40 CFR Part 63 Approval of the Clean Air Act, Section 112(l), Authority for Hazardous Air Pollutants: Air Emission Standards for Halogenated Solvent Cleaning Machines: State of Rhode Island... Emissions from Organic Solvent Cleaning (``RI Regulation No. 36'') and Rhode Island Air Pollution...

  16. Compressed air of water-injected screw compressors is clean; Druckluft von wassereingespritzten Schraubenkompressoren ist sauber

    Energy Technology Data Exchange (ETDEWEB)

    Thomassen, Volker

    2010-08-09

    The oil content of compressed air has become an issue in industrial compressed air supply, especially from the view of environmental protection and waste management. The article specifies requirements on compressed air systems that are to ensure clean compressed air supply. (orig.)

  17. 17th DOE nuclear air cleaning conference: proceedings. Volume 2

    Energy Technology Data Exchange (ETDEWEB)

    First, M.W. (ed.)

    1983-02-01

    Volume 2 contains papers presented at the following sessions: adsorption; noble gas treatment; personnel education and training; filtration and filter testing; measurement and instrumentation; air cleaning equipment response to accident related stress; containment venting air cleaning; and an open end session. Twenty-eight papers were indexed separately for inclusion in the Energy Data Base. Ten papers had been entered earlier.

  18. A brief history of the air cleaning conferences

    International Nuclear Information System (INIS)

    I have been asked to prepare a history of the air cleaning conferences. Undertaking such a task is, of course, a wonderful opportunity for reminiscences and a chance to retell old war stories. I must admit that it has taken much longer than I anticipated because I found myself so completely engrossed rereading the old records that time seemed to stop, although the hours passed. But a history of the nuclear air cleaning conferences means more than a stroll down memory lane. The 23 recorded air cleaning conference proceedings reflect an important aspect of the history of major nuclear developments, both military and civilian, because engineered safety features designed to prevent dispersion of radioactive products to the environment have always been a necessity for progress in this field. For this reason, I hope the history of the nuclear air cleaning conferences will not only be enjoyable, but also have meaning for young people entering this field. The air cleaning conferences were an outgrowth of the operations of the U.S. Atomic Energy Commission's (AEC) Stack Gas Working Group established in 1948 to review air cleaning operations at AEC installations. AEC's Division of Engineering sponsored and funded air cleaning research and development at Harvard University's School of Public Health, beginning about the same time. In addition to research and development, the Harvard contract called for consulting and educational services. The latter provided the opportunity for meetings devoted to information on air cleaning that could be applied to ongoing and anticipated nuclear operations

  19. 17th DOE nuclear air cleaning conference: proceedings. Volume 2

    International Nuclear Information System (INIS)

    Volume 2 contains papers presented at the following sessions: adsorption; noble gas treatment; personnel education and training; filtration and filter testing; measurement and instrumentation; air cleaning equipment response to accident related stress; containment venting air cleaning; and an open end session. Twenty-eight papers were indexed separately for inclusion in the Energy Data Base. Ten papers had been entered earlier

  20. Ceramic membrane defouling (cleaning) by air Nano Bubbles.

    Science.gov (United States)

    Ghadimkhani, Aliasghar; Zhang, Wen; Marhaba, Taha

    2016-03-01

    Ceramic membranes are among the most promising technologies for membrane applications, owing to their excellent resistance to mechanical, chemical, and thermal stresses. However, membrane fouling is still an issue that hampers the applications at large scales. Air Nano Bubbles (NBs), due to high mass transfer efficiency, could potentially prevent fouling of ceramic membrane filtration processes. In this study, bench and pilot scale ceramic membrane filtration was performed with air NBs to resist fouling. To simulate fouling, humic acid, as an organic foulant, was applied to the membrane flat sheet surface. Complete membrane clogging was achieved in less than 6 h. Membrane defouling (cleaning) was performed by directly feeding of air NBs to the membrane cells. The surface of the ceramic membrane was superbly cleaned by air NBs, as revealed by atomic force microscope (AFM) images before and after the treatment. The permeate flux recovered to its initial level (e.g., 26.7 × 10(-9) m(3)/m(2)/s at applied pressure of 275.8 kPa), which indicated that NBs successfully unclogged the pores of the membrane. The integrated ceramic membrane and air NBs system holds potential as an innovative sustainable technology. PMID:26741542

  1. Removal of Particles from the Supply Air of Ventilation Systems Avoiding the Formation of Sensory Pollution Source:Delivery of Clean Air to Building Occupants

    OpenAIRE

    Bekö, Gabriel

    2008-01-01

    Used ventilation filters can act as sources of strong sensory pollution. The pollutants emitted from loaded particle filters may include irritating products of chemical reactions occurring on the filter surfaces. Most likely oxidation reactions, especially those driven by ozone, seem to play an important role. Sensory pollutants emitted from used filters can have significant adverse impact on occupant performance. Therefore, removal of particles from the supply air of ventilation systems with...

  2. Clean air strategy for Alberta: Background project reports

    International Nuclear Information System (INIS)

    As a background to the development of a clean air strategy for Alberta, reports are presented which cover the definition of what clean air is, the applicability of full cost accounting to this strategy, market-based approaches to managing Alberta air emissions, gas and electric utility incentives programs for energy efficiency, energy efficiency legislation in Alberta and other jurisdictions, initiatives which address emissions reduction in the transportation sector, coordination of science and technology relevant to clean air issues, and initiatives in energy and environmental education

  3. Air cleaning issues with contaminated sites

    Energy Technology Data Exchange (ETDEWEB)

    Bellamy, R.R. [Nuclear Regulatory Commission, King of Prussia, PA (United States)

    1997-08-01

    The US Nuclear Regulatory Commission has developed a list of contaminated sites that warrant special USNRC attention because they pose unique or complex decommissioning issues. This list of radiologically contaminated sites is termed the Site Decommissioning Management Plan (SDMP), and was first issued in 1990. A site is placed on the SDMP list if it has; (1) Problems with the viability of the responsible organization (e.g., the licensee for the site is unable or unwilling to pay for the decommissioning); (2) Large amounts of soil contamination or unused settling ponds or burial grounds that may make the waste difficult to dispose of; (3) The long-term presence of contaminated, unused buildings; (4) A previously terminated license; or (5) Contaminated or potential contamination of the ground water from on-site wastes. In deciding whether to add a site to the SDMP list, the NRC also considers the projected length of time for decommissioning and the willingness of the responsible organization to complete the decommissioning in a timely manner. Since the list was established, 9 sites have been removed from the list, and the current SDMP list contains 47 sites in 11 states. The USNRC annually publishes NUREG-1444, {open_quotes}Site Decommissioning Management Plan{close_quotes}, which updates the status of each site. This paper will discuss the philosophical goals of the SDMP, then will concentrate on the regulatory requirements associated with air cleaning issues at the SDMP sites during characterization and remediation. Both effluent and worker protection issues will be discussed. For effluents, the source terms at sites will be characterized, and measurement techniques will be presented. Off-site dose impacts will be included. For worker protection issues, air sampling analyses will be presented in order to show how the workers are adequately protected and their doses measured to satisfy regulatory criteria during decontamination operations. 1 tab.

  4. 75 FR 34647 - Approval of the Clean Air Act, Section 112(l), Authority for Hazardous Air Pollutants: Air...

    Science.gov (United States)

    2010-06-18

    .... See 64 FR 67793. Continuous web cleaning machines are solvent cleaning machines in which parts such as... Pollutants: Air Emission Standards for Halogenated Solvent Cleaning Machines: State of Rhode Island... Emissions from Organic Solvent Cleaning (``RI Regulation No. 36''), and the Rhode Island Air...

  5. 76 FR 66717 - Notification of a Public Teleconference of the Clean Air Scientific Advisory Committee Air...

    Science.gov (United States)

    2011-10-27

    ... AGENCY Notification of a Public Teleconference of the Clean Air Scientific Advisory Committee Air... announces a public teleconference of the Clean Air Scientific Advisory Committee (CASAC) Air Monitoring and... site at http://www.epa.gov/casac . Any inquiry regarding EPA's draft Near-Road NO 2...

  6. CAN SORBENT-BASED GAS PHASE AIR CLEANING FOR VOCS SUBSTITUTE FOR VENTILATION IN COMMERCIAL BUILDINGS?

    OpenAIRE

    Fisk, William J.

    2008-01-01

    This paper reviews current knowledge about the suitability of sorbent-based air cleaning for removing volatile organic compounds (VOCs) from the air in commercial buildings, as needed to enable reductions in ventilation rates and associated energy savings. The principles of sorbent air cleaning are introduced, criteria are suggested for sorbent systems that can counteract indoor VOC concentration increases from reduced ventilation, major findings from research on sorbent performance for this...

  7. CLEAN-AIR heat pump. Reduced energy consumption for ventilation in buildings by integrating air cleaning and heat pump. Final Report; CLEAN-AIR heat pump - Reduceret energiforbrug til ventilation af bygninger ved luftrensning integreret med luft varmepumpe. Slut rapport

    Energy Technology Data Exchange (ETDEWEB)

    Fang, L.; Olesen, Bjarne W.; Molinaro, G.; Simmonsen, P.; Skocajic, S. [Danmarks Tekniske Univ. Institut for Byggeri og Anlaeg, Lyngby (Denmark); Hummelshoej, R.M.; Carlassara, L. [COWI A/S, Lyngby, (Denmark); Groenbaek, H.; Hansen, Ole R. [Exhausto A/S, Langeskov (Denmark)

    2011-07-01

    This report summarizes task 1 of the Clean Air Heat Pump project - modelling and simulation on energy savings when using the clean air heat pump for ventilation, air cleaning and energy recovery. The total energy consumption of the proposed ventilation systems using clean air heat pump technology was calculated by a theoretical model and compared with the reference ventilation systems (conventional ventilation systems). The energy compared between the two systems includes energy used for heating, cooling and fan. The simulation and energy saving calculation was made for the application of the clean air heat pump in three typical climate conditions, i.e. mild-cold, mild-hot and hot and wet climates. Real climate data recorded from three cities in 2002 was used for the calculation. The three cities were Copenhagen (Denmark), Milan (Italy) and Colombo (Sir Lanka) which represent the above three typical climate zones. For the Danish climate (the mild cold climate), the calculations show that the ventilation system using clean air heat pump technology can save up to 42% of energy cost in winter compared to the conventional ventilation system. The energy saving in summer can be as high as 66% for the ventilation system with humidity control and 9% for the ventilation system without the requirement of humidity control. Since the Danish summer climate is very mild, over 80% of the yearly energy consumption for ventilation is used during winter season. It is, therefore, estimated that more than 35% annual energy saving for ventilation is expected in Denmark using the clean air heat pump ventilation technology. For the mild hot climate, e.g. the Italian climate, the calculations show that up to 63% of the energy saving can be achieved in summer season. For the winter mode, 17% reduction of the energy cost can be expected for the domestic use. For industrial use, the energy cost of the clean air heat pump may not be favourable due to the industrial price of gas in Italy is

  8. New Air Cleaning Strategies for Reduced Commercial Building Ventilation Energy ? FY11 Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Sidheswaran, Meera; Destaillats, Hugo; Cohn, Sebastian; Sullivan, Douglas P.; Fisk, William J.

    2011-10-31

    The research carried out in this project focuses on developing novel volatile organic compounds (VOCs) air cleaning technologies needed to enable energy-saving reductions in ventilation rates. we targeted a VOC air cleaning system that could enable a 50% reduction in ventilation rates. In a typical commercial HVAC system that provides a mixture of recirculated and outdoor air, a VOC air cleaner in the supply airstream must have a 15% to 20% VOC removal efficiency to counteract a 50% reduction in outdoor air supply.

  9. Evaluation of air cleaning technologies existing in the Danish market

    DEFF Research Database (Denmark)

    Ardkapan, Siamak Rahimi; Afshari, Alireza; Bergsøe, Niels Christian;

    2014-01-01

    Five portable air cleaning technologies including one new technology were evaluated to find their effectiveness in removing ultrafine particles. Measurements were carried out both in a duct and in a test room. The results showed that the technologies that use/create ozone to clean air can increase...... the ozone level significantly in the room. Moreover, they can cause generation of ultrafine particles and consequently increase ultrafine particle concentration in the room. The study suggests using a mechanical filter with low pressure drop as a recommended air cleaning technology in order to remove...

  10. Nuclear air cleaning: the need for a change in emphasis

    International Nuclear Information System (INIS)

    The nuclear industry now has over 35 years of experience in nuclear air cleaning. This experience covers technology development, system design, operations, and maintenance. Much of the past experience has been directed towards technology development with particular emphasis on high efficiency particulate air (HEPA) filters. Implementation of this technology has lagged its development by a number of years. A recent study examines the causes and frequencies of HEPA filter changeouts and failures. These data lead to a conclusion that a shift in emphasis from technology development to the training of personnel and the designing and maintaining of such systems is needed. Some highlights of the data and a discussion of topics which should be addressed in training will be presented. 7 references, 5 tables

  11. Nuclear air cleaning: the need for a change in emphasis

    International Nuclear Information System (INIS)

    The nuclear industry now has over 35 years of experience in nuclear air cleaning. This experience covers technology development, system design, operations, and maintenance. Much of the past experience has been directed towards technology development with particular emphasis on high efficiency particulate air (HEPA) filters. Implementation of this technology has lagged its development by a number of years. A recent study examines the cause and frequencies of HEPA filter changeouts and failures. These data lead to a conclusion that a shift in emphasis from technology development to the training of personnel and the designing and maintaining of such systems is needed. Some highlights of the data and a discussion of topics which should be addressed in training will be presented

  12. Some impacts of the 1990 Clean Air Act and state clean-air regulations on the fertilizer industry

    International Nuclear Information System (INIS)

    The Clean Air Act amendments of 1990 will intensify national efforts to reduce air pollution. They will have major impacts on governmental agencies and on industrial and commercial facilities throughout the country. As with other industries, it is essential for fertilizer dealers and producers to understand how these changes to the Clean Air Act can significantly change the way they do business. This paper is proffered as an overview of ways in which the 1990 amendments to the Clean Air Act may impact the fertilizer industry. The nonattainment, toxics, and permit provisions of the amended act will be three areas of particular concern to the fertilizer industry. Implementation of the new regulatory requirements of this legislation promises to be a long and onerous process for all concerned. However, it appears that state and local regulations may have a much more profound impact on the fertilizer industry than the new Clean Air Act

  13. Effect of clean indoor air laws on smokers: the clean air module of the SimSmoke computer simulation model

    OpenAIRE

    Levy, D.; Friend, K; Polishchuk, E

    2001-01-01

    OBJECTIVES—To develop a simulation model to examine the effects of clean indoor air laws on prevalence rates and smoking attributable deaths.
METHODS—Based on empirical and theoretical research, the effects of clean air laws are modelled by type of law. The model considers clean air laws at the state levels between 1993 and 2000, and projects the number of smokers and smoking attributable deaths in the USA under different scenarios from 2000 onward.
RESULTS—The model predicts that comprehensi...

  14. Proceedings of the fifteenth DOE nuclear air cleaning conference

    Energy Technology Data Exchange (ETDEWEB)

    First, M.W. (ed.)

    1979-02-01

    Papers presented are grouped under the following topics: noble gas separation, damage control, aerosols, test methods, new air cleaning technology from Europe, open-end, and filtration. A separate abstract was prepared for each paper.

  15. EnviroAtlas - Clean Air Metrics for Conterminous United States

    Data.gov (United States)

    U.S. Environmental Protection Agency — This EnviroAtlas web service supports research and online mapping activities related to EnviroAtlas (https://www.epa.gov/enviroatlas). The Clean Air category in...

  16. 75 FR 11560 - Notice of Lodging of Consent Decree Under the Clean Water Act and Clean Air Act

    Science.gov (United States)

    2010-03-11

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF JUSTICE Notice of Lodging of Consent Decree Under the Clean Water Act and Clean Air Act Notice is hereby given that... violations of the Clean Water Act, 33 U.S.C. 1251 et seq., and the Clean Air Act, 42 U.S.C. 7401 et seq....

  17. 78 FR 70960 - Notice of Lodging of Consent Decree Under the Clean Air Act, Clean Water Act, and the Resource...

    Science.gov (United States)

    2013-11-27

    ... of Lodging of Consent Decree Under the Clean Air Act, Clean Water Act, and the Resource Conservation... the United States and the State of Illinois under the Clean Air Act, the Clean Water Act, the Resource... and Natural Resource Division. BILLING CODE 4410-15-P...

  18. Food-Growing, Air- And Water-Cleaning Module

    Science.gov (United States)

    Sauer, R. L.; Scheld, H. W.; Mafnuson, J. W.

    1988-01-01

    Apparatus produces fresh vegetables and removes pollutants from air. Hydroponic apparatus performs dual function of growing fresh vegetables and purifying air and water. Leafy vegetables rooted in granular growth medium grow in light of fluorescent lamps. Air flowing over leaves supplies carbon dioxide and receives fresh oxygen from them. Adaptable to production of food and cleaning of air and water in closed environments as in underwater research stations and submarines.

  19. Development of clean chemical mechanical polishing systems; Clean CMP system

    Energy Technology Data Exchange (ETDEWEB)

    Tsujimura, M.; Hosokawa, M. [Ebara Corp., Tokyo (Japan)

    1998-10-20

    Described herein are clean chemical mechanical polishing (CMP) systems developed by Ebara. A CMP system needs advanced peripheral techniques, in addition to those for grinding adopted by the conventional system, in order to fully exhibit its inherent functions. An integrated design concept is essential for the CMP steps, including slurry supplying, polishing, washing, process controlling and waste fluid treatment. The Ebara has adopted a standard concept `Clean CMP, dry-in and dry-out of wafers,` and provided world`s highest grades of techniques for inter-layer insulating film, shallow trench isolation, plug and wiring. The head for the polishing module is specially designed by FEM, to improve homogeneity of wafers from the center to edges. The dresser is also specially designed, to improve pad surface topolody after dressing. A slurry dipsersing method is developed to reduce slurry consumption. Various washing modules, designed to have the same external shape, can be allocated to various functions. 10 figs.

  20. Clean Air Slots Amid Atmospheric Pollution

    Science.gov (United States)

    Hobbs, Peter V.

    2002-01-01

    This article investigates the mechanism for those layers in the atmosphere that are free of air borne pollution even though the air above and below them carry pollutants. Atmospheric subsidence is posed as a mechanism for this phenomenon.

  1. Condensate cleaning systems

    International Nuclear Information System (INIS)

    Purpose: To decrease the frequency for the backwash and regeneration operations due to the increase in the differential pressure resulted from claddings captured in a mixed floor type desalter, and decrease the amount of radioactive liquid wastes of claddings from the condensate systems by removing claddings with electromagnetic filters. Constitution: In an existent plant, a valves is disposed between a condensate pump and a mixed floor type desalter. A pipeway is branched from a condensate pipe between the condensate pipe and the valve, through which condensates are transferred by a pump to an electromagnetic filter such as of a high gradient type electromagntic filter to remove claddings, then returned to a condensate pipe between the valve and the mixed floor type desalter and, thereafter, are removed with ionic components in the mixed floor type desalter and fed to the reactor. (Yoshino, Y.)

  2. Clean Air Slots Amid Dense Atmospheric Pollution in Southern Africa

    Science.gov (United States)

    Hobbs, Peter V.

    2003-01-01

    During the flights of the University of Washington's Convair-580 in the Southern African Regional Science Initiative (SAFARI 2000) in southern Africa, a phenomenon was observed that has not been reported previously. This was the occurrence of thin layers of remarkably clean air, sandwiched between heavily polluted air, which persisted for many hours during the day. Photographs are shown of these clean air slots (CAS), and particle concentrations and light scattering coefficients in and around such slot are presented. An explanation is proposed for the propensity of CAS to form in southern Africa during the dry season.

  3. Experimental evaluation of acoustic agglomerators as an air cleaning system concept for emergency use in LMFBR plants. Final report

    International Nuclear Information System (INIS)

    In the development of the Liquid Metal Fast Breeder Reactor, a major safety problem concerns the suppression of the sodium oxides aerosol particles produced during a hypothetical core disruptive accident. Some theoretical calculations are presented concerning sonic agglomeration rates of such a system in terms of acoustic frequency, intensity and particles. The information is useful in providing some guidelines for the evaluation and design of sonic systems for LMFBR emergency applications

  4. Fundamentals of air cleaning technology and its application in cleanrooms

    CERN Document Server

    Xu, Zhonglin

    2014-01-01

    Fundamentals of Air Cleaning Technology and Its Application in Cleanrooms sets up the theoretical framework for cleanrooms. New ideas and methods are presented, which include the characteristic index of cleanrooms, uniform and non-uniform distribution characteristics, the minimum sampling volume, a new concept of outdoor air conditioning and the fundamentals of leakage-preventing layers. Written by an author who can look back on major scientific achievements and 50 years of experience in this field, this book offers a concise and accessible introduction to the fundamentals of air cleaning technology and its application. The work is intended for researchers, college teachers, graduates, designers, technicians and corporate R&D personnel in the field of HVAC and air cleaning technology. Zhonglin Xu is a senior research fellow at China Academy of Building Research.

  5. Ionization Impact on the Air Cleaning Efficiency in the Interior

    OpenAIRE

    Černecký Jozef; Valentová Karina; Pivarčiová Elena; Božek Pavol

    2015-01-01

    The paper deals with ionization impact on efficient cleaning of air in a measuring chamber which has been cleaned and closed against any outer impacts (e.g. impurities, dust from another room, human odours). Smoking has an impact on the number of positive and negative ions including the concentration of particulate matter PM10. We investigated the ion concentration according to the presence of cigarette smoke in the room and according to the change of lit cigarette distance from the supply of...

  6. Self-Cleaning Particulate Air Filter Project

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA requires an innovative solution to the serious issue of particulate fouling on air revitalization component surfaces in order to address the potential for...

  7. Can carpooling clean the air? The economics of HOV lanes, hybrid cars and the Clean Air Act.

    OpenAIRE

    Shewmake, Sharon

    2010-01-01

    Private vehicles are a significant source of air pollution in many areas of the United States. Areas with already high levels of air pollution are required by the Clean Air Act to take steps to reduce automobile use and the associated emissions. The behavioral implications of many travel demand management techniques are poorly understood. In this dissertation I focus on carpooling. Policy makers encourage commuters to carpool through High Occupancy Vehicle (HOV) Lanes, fre...

  8. Lifa Air Secure Box method for chilled beam cleaning

    OpenAIRE

    Leppälä, Vesa-Jukka

    2014-01-01

    The objective of this Bachelor’s Thesis was to introduce a chilled beam cleaning method and to develop an improved version for the prototype introduced in 2011. This thesis was commissioned by Lifa Air Ltd. The company itself is specialized in improving Indoor Air Quality and offers a wide range of products meant for ventilation cleaning. The aim for the development work was to fill the requirements and needs set by the company based on the research done, and to construct a working and improv...

  9. Precision Cleaning of Oxygen Systems and Components

    Science.gov (United States)

    McLaughlin, Russell

    2009-01-01

    Currently, NASA uses Dichloropentafluoropropane (HCFC-225), a Class II ozone depleting substance (ODs), to clean contaminated oxygen systems. Starting in 20 15, the Montreal Protocols and Clean Air Act prohibit the production and importation of all hydrochlorofluorocarbons (HCFC), except for limited use in refrigeration applications. Thus, a new non-ozone depleting solvent needs to be developed for use in cleaning. Optimally, such a solvent should also be environmentally benign or green to avoid needing to replace the new solvent with yet another solvent in the future due to other environmental concerns. Work for the first year consisted of two parts. The first part was developing a method of testing the cleaning efficiency of potential solvents. Stainless steel coupons were contaminated with a known weight of various contaminants and contaminant combinations and then immersed in solvent for ten minutes. The coupons were then removed and dried in an oven until all solvent had evaporated. Once dry, the coupons were weighed and the mass of the non-volatile residue (NVR) left on the coupon was determined. The cleaning efficiency of the solvents is reported as percent cleaning, with 100% cleaning being zero NVR left on the test coupon. The second half of the first goal was to use the develop method to perform baseline testing on current solvents. The second part of the work was to begin exploring alternative cleaning solvents. A variety of hydrofluorocarbons (HFCs) were tested. Preliminary testing was also performed with ionic liquids and aqueous surfactant solutions. Once potential solvents were identified, an analysis of the performance and environmental characteristics of each was to be conducted. Four contaminants were specified for use in testing. These are Mil-Spec-H-5606 (5606), a hydraulic fluid, Mil-H-83282B (83282), another hydraulic fluid, diethylhexyl sebacate (Sebacate), and WD-40. The structures of these contaminants are all similar, with long aliphatic

  10. Beam Cleaning and Collimation Systems

    CERN Document Server

    Redaelli, S

    2016-01-01

    Collimation systems in particle accelerators are designed to dispose of unavoidable losses safely and efficiently during beam operation. Different roles are required for different types of accelerator. The present state of the art in beam collimation is exemplified in high-intensity, high-energy superconducting hadron colliders, like the CERN Large Hadron Collider (LHC), where stored beam energies reach levels up to several orders of magnitude higher than the tiny energies required to quench cold magnets. Collimation systems are essential systems for the daily operation of these modern machines. In this document, the design of a multistage collimation system is reviewed, taking the LHC as an example case study. In this case, unprecedented cleaning performance has been achieved, together with a system complexity comparable to no other accelerator. Aspects related to collimator design and operational challenges of large collimation systems are also addressed.

  11. Air toxics and the 1990 Clean Air Act: Managing trace element emissions

    International Nuclear Information System (INIS)

    The US Environmental Protection Agency (EPA) has historically regulated air toxics (hazardous air pollutants) under Section 112 of the Clean Air Act. To date, EPA has established emission standards for 8 hazardous air pollutants (arsenic, asbestos, benzene, beryllium, mercury, radionuclides, coke oven emissions and vinyl chloride). The US electric utility industry was not determined to be a source category requiring regulation for any of the eight chemicals. Of the eight, radionuclides were the last species for which EPA established hazardous emissions standards. In this instance, EPA determined that the risks associated with electric utility fossil fuel power plant emissions were sufficiently low that they should not be regulated. However, the 1990 Clean Air Act Amendments require a new evaluation of the electric utility industry emissions of hazardous air pollutants. This paper summarizes the key features of the air toxics provisions of the Clean Air Act Amendments, describes EPRI's activities on the subject, and provides some preliminary insights from EPRI's research to date

  12. Clean the Air and Breathe Easier.

    Science.gov (United States)

    Guevin, John

    1997-01-01

    Failure to prevent indoor air quality problems or act promptly can result in increased chances for long- or short-term health problems for staff and students, reduced productivity, faster plant deterioration, and strained school-community relations. Basic pollution control measures include source management, local exhausts, ventilation, exposure…

  13. Effect of Air Cleaning Technologies in Conjunction With the Use of Rotary Heat Exchangers in Residential Buildings

    OpenAIRE

    Afshari, Alireza; Bergsøe, Niels Christian; Ekberg, Lars

    2013-01-01

    This study is part of a research project concerning the possibilities of applying efficient air cleaning technologies using rotary heat exchanger in residential buildings. The purpose of this project was to identify and adapt new air-cleaning technologies for implementation in HVAC systems with rotary air-to-air heat exchangers. For this purpose, a mechanical filter with low pressure drop and a 4 cm thick activated carbon filter were selected for testing in a laboratory environment. The measu...

  14. Indoor Air Quality in Schools: Clean Air Is Good Business.

    Science.gov (United States)

    Guarneiri, Michele A.

    2003-01-01

    Describes the effect of poor indoor air quality (IAQ) on student health, the cost of safeguarding good IAQ, the cause of poor IAQ in schools, how to tell whether a school has an IAQ problem, and how the U.S. Environmental Protection Agency can help schools improve indoor air quality though the use of their free "Indoor Air Quality Tools for…

  15. Energy Saving Measures of Clean Air Conditioning System in Solid Dosage Forms Workshop of Pharmaceutical Companies%浅谈药厂固体制剂车间净化空调系统的节能措施

    Institute of Scientific and Technical Information of China (English)

    张帆

    2012-01-01

    According to large energy consumption of clean air-conditioning system in solid dosage forms workshop of pharmaceutical companies, combining with the project cases, this paper suggests three energy saving measures.%针对药厂固体制剂车间净化空调系统能耗大的问题,结合具体的工程案例,有针对性地提出了几种有效的节能措施。

  16. VOCs and formaldehyde emissions from cleaning products and air fresheners

    OpenAIRE

    Solal, Cécilia; Rousselle, Christophe; Mandin, Corinne; Manel, Jacques; Maupetit, François

    2008-01-01

    Human indoor exposure to Volatile Organic Compounds (VOCs) may be associated with the use of household products. However little is known about their emissions and to what extent they contribute to indoor air pollution. The French Agency for Environmental and Occupational Health Safety (Afsset) conducted tests in order to characterize VOCs emissions from 32 consumer products: air fresheners, glass cleaners, furniture polishes, toilet products, carpet and floor cleaning products. All experiment...

  17. Scaleable Clean Aluminum Melting Systems

    Energy Technology Data Exchange (ETDEWEB)

    Han, Q.; Das, S.K. (Secat, Inc.)

    2008-02-15

    The project entitled 'Scaleable Clean Aluminum Melting Systems' was a Cooperative Research and Development Agreements (CRADAs) between Oak Ridge National Laboratory (ORNL) and Secat Inc. The three-year project was initially funded for the first year and was then canceled due to funding cuts at the DOE headquarters. The limited funds allowed the research team to visit industrial sites and investigate the status of using immersion heaters for aluminum melting applications. Primary concepts were proposed on the design of furnaces using immersion heaters for melting. The proposed project can continue if the funding agency resumes the funds to this research. The objective of this project was to develop and demonstrate integrated, retrofitable technologies for clean melting systems for aluminum in both the Metal Casting and integrated aluminum processing industries. The scope focused on immersion heating coupled with metal circulation systems that provide significant opportunity for energy savings as well as reduction of melt loss in the form of dross. The project aimed at the development and integration of technologies that would enable significant reduction in the energy consumption and environmental impacts of melting aluminum through substitution of immersion heating for the conventional radiant burner methods used in reverberatory furnaces. Specifically, the program would couple heater improvements with furnace modeling that would enable cost-effective retrofits to a range of existing furnace sizes, reducing the economic barrier to application.

  18. Index to the AEC/ERDA/DOE Air Cleaning Conferences

    International Nuclear Information System (INIS)

    A comprehensive index to the papers in the second through sixteenth AEC/ERDA/DOE Nuclear Air Cleaning Conference is discussed. The index will be published in early 1981 and will be designated as Volume 3 of the proceeding of the sixteenth conference. The index has three parts, a straight numeric tabulation, an author index, and a key word in context (KWIC) index

  19. Proceedings of the fifteenth DOE nuclear air cleaning conference

    Energy Technology Data Exchange (ETDEWEB)

    First, M.W. (ed.)

    1979-02-01

    Papers presented are grouped under the following topics: air cleaning; waste volume reduction and preparation for storage; tritium, carbon-14, ozone; containment of accidental releases; adsorbents and absorbents; and off-gas treatment. A separate abstract was prepared for each paper.

  20. Cleaning of outgoing air at companies reprocessing residual material; Abluftreinigung fuer Reststoffverwertungsbetriebe

    Energy Technology Data Exchange (ETDEWEB)

    Rafflenbeul, R. [Rafflenbeul und Partner, Frankfurt am Main (Germany)

    1996-05-01

    With the extension of the federal act for the protection against nuisances to companies reprocessing residual material and, concomitantly, their obligation from 1997 to obtain a licence, outgoing-air cleaning systems for the removal of odorous nuisances will become indispensable. Because of want of information on the part of many operators, scrubbers, and in part even air cleaning systems with after-burning, are still frequently used. The article gives an overview of the different techniques for cleaning outgoing air such as scrubbers, biological methods as well as plasma and bioplasma techniques. (orig./SR) [Deutsch] Mit der Neueingliederung der Reststoffverwertungsbetriebe in das Bundesimmissionschutz-Gesetz, und hiermit verknuepft der ab 1997 erforderlichen Genehmigungspflicht, werden Abluftreinigungsverfahren zur Geruchsbeseitigung unumgehbar. Aus Unkenntnis der Betreiber gelangen immer noch Waschverfahren, zum Teil sogar nachverbrennend wirkende Abluftreinigungssysteme, zur Anwendung. Es wird ein Ueberblick ueber die verschiedenen Abluftreinigungsverfahren wie Waescher, biologische Verfahren sowie Plasma- und Bioplasmaverfahren gegeben. (orig./SR)

  1. Unequal State Air Pollution: Adopting and Adapting to State Clean Air Policy

    Science.gov (United States)

    Glasgow, Derek John

    This dissertation looks at the relationship between American subnational governments and clean air policy in three different cases. I investigate the impact of state reduction policies on the emission of Greenhouse emissions, the subnational adoption of Greenhouse Gas tracking and reduction policies, and the impact of Clean Air Act standards on the siting of coal-fired power plants. The major finding is that in both the adoption and business response to these policies, a state's political context can limit its ability to regulate air pollution. These factors contribute to the unequal protection of air quality across the United States.

  2. Cleaning products and air fresheners: exposure to primary and secondary air pollutants

    DEFF Research Database (Denmark)

    Nazaroff, W.; Weschler, Charles J.

    2004-01-01

    Building occupants, including cleaning personnel, are exposed to a wide variety of airborne chemicals when cleaning agents and air fresheners are used in buildings. Certain of these chemicals are listed by the state of California as toxic air contaminants (TACs) and a subset of these are regulated...... chemicals that can react with other air contaminants to yield potentially harmful secondary products. For example, terpenes can react rapidly with ozone in indoor air generating many secondary pollutants, including TACs such as formaldehyde. Furthermore, ozone-terpene reactions produce the hydroxyl radical...

  3. Air and gas cleaning technology for nuclear applications

    International Nuclear Information System (INIS)

    All large-scale uses of radioactive materials require rigid control of off-gases and generated aerosols. Nuclear air and gas cleaning technology has answered the need from the days of the Manhattan Project to the present with a variety of devices. The one with the longest and most noteworthy service is the HEPA (high efficiency particulate air) filter that originally was referred to as an absolute filter in recognition of its extraordinary particle retention characteristics. Activated-charcoal adsorbers have been employed worldwide for retention of volatile radioiodine in molecular and combined forms and, less frequently, for retention of radioactive noble gases. HEPA filters and activated -charcoal adsorbers are often used with auxiliary devices that serve to extend their effective service life or significantly improve collection efficiency under unfavorable operating conditions. Use of both air cleaning devices and their auxiliaries figure prominently in atomic energy, disposal of high- and low-level nuclear wastes, and in the production of fissile materials. The peaceful uses of nuclear energy would be impossible without these, or equivalent, air- and gas-cleaning devices

  4. Design, build, and test an air-cleaning system for working-level control in uranium mines. Open file report October 1979-April 1984

    International Nuclear Information System (INIS)

    The health hazard from 222 radon byproducts, radon daughters, will be increasingly difficult to control by dilution with primary ventilation as the uranium industry digs farther and deeper for ore of diminishing grade. One solution is removal of daughters from air at the work place by filtering out respirable-size dust particles to which most daughters attach. This report describes design and testing of a filtration unit that reduces the working level in ventilating air 95% on an airflow of 10,000 cfm. Buildup of dust on the filter is controlled by periodic back-pulsing, so that the unit can operate for an extended period without changing elements. The effectiveness of the self-cleaning action was satisfactory under a contaminant loading that was 43% diesel smoke. Back-pulsing was able to control filter loading or buildup to a degree even under 100% diesel. The report describes testing of the filter medium and filter unit in both an experimental and an active mine and concludes with an analysis of the prototype design

  5. Nuclear air cleaning programs in progress in France

    International Nuclear Information System (INIS)

    A short presentation is given of the nuclear air cleaning programs in progress in France with respect to pressurized water reactors, fuel reprocessing plants, radioactive waste management facilities, and the dismantling of nuclear facilities. The effects of fires in rooms and ventilation ducts in all nuclear facilities is being studied and computer simulation codes are being developed. A brief review of filter development and filter testing is also presented

  6. The problem of highly effective cleaning of air from dust

    OpenAIRE

    Batluk, V. A.; Romantsov, E. V.; Klymets, V. M.

    2013-01-01

    This article deals with the problem of providing high performance apparatuses for cleaning air from dust in various branches of industry in order to reduce hazardous emissions to the level of conforming to the sanitary-hygienic norms. The article describes new trends in the development of dust catching apparatuses based on the use of centrifugal-inertial forces, permitting to improve significantly the dust catching efficacy.

  7. Ethanol Policy in the Clean Air-Free Trade Era

    OpenAIRE

    Rask, Norman; Rask, Kevin; Tiefenthaler, Jill

    1993-01-01

    The U.S. corn ethanol industry is a subsidized, high cost, trade protected, limited scale industry; unable to compete in free markets orto efficiently supply new fuel demands of clean air legislation. Lower cost, sugarcane ethanol from Latin America (Brazil) should be asupplementary source, especially for U.S. coastal markets. Counter trade-corn for ethanolwould be more beneficial to U.S. corn producers than domestic ethanol corn markets and would result in more efficient land use, less soil ...

  8. 75 FR 79369 - Clean Air Act Advisory Committee (CAAAC): Notice of Meeting

    Science.gov (United States)

    2010-12-20

    ... AGENCY Clean Air Act Advisory Committee (CAAAC): Notice of Meeting AGENCY: Environmental Protection... Clean Air Act Advisory Committee (CAAAC) on November 19, 1990, to provide independent advice and counsel to EPA on policy issues associated with implementation of the Clean Air Act of 1990. The...

  9. 78 FR 77448 - Clean Air Act Advisory Committee (CAAAC): Notice of Meeting

    Science.gov (United States)

    2013-12-23

    ... AGENCY Clean Air Act Advisory Committee (CAAAC): Notice of Meeting AGENCY: Environmental Protection... public meetings of the Clean Air Act Advisory Committee (CAAAC). The EPA established the CAAAC on... implementation of the Clean Air Act of 1990. The Committee advises on economic, environmental,...

  10. 75 FR 1379 - Clean Air Act Advisory Committee (CAAAC): Notice of Meeting

    Science.gov (United States)

    2010-01-11

    ... AGENCY Clean Air Act Advisory Committee (CAAAC): Notice of Meeting AGENCY: Environmental Protection... Clean Air Act Advisory Committee (CAAAC) on November 19, 1990, to provide independent advice and counsel to EPA on policy issues associated with ] implementation of the Clean Air Act of 1990. The...

  11. 78 FR 49511 - Clean Air Act Advisory Committee (CAAAC): Notice of Meeting

    Science.gov (United States)

    2013-08-14

    ... AGENCY Clean Air Act Advisory Committee (CAAAC): Notice of Meeting AGENCY: Environmental Protection... public meeting of the Clean Air Act Advisory Committee (CAAAC). The EPA established the CAAAC on November... implementation of the Clean Air Act of 1990. The Committee advises on economic, environmental,...

  12. 75 FR 25855 - Clean Air Act Advisory Committee (CAAAC): Notice of Meeting

    Science.gov (United States)

    2010-05-10

    ... AGENCY Clean Air Act Advisory Committee (CAAAC): Notice of Meeting AGENCY: Environmental Protection... Clean Air Act Advisory Committee (CAAAC) on November 19, 1990, to provide independent advice and counsel to EPA on policy issues associated with implementation of the Clean Air Act of 1990. The...

  13. 77 FR 66462 - Clean Air Act Advisory Committee; Notice of Charter Renewal

    Science.gov (United States)

    2012-11-05

    ... AGENCY Clean Air Act Advisory Committee; Notice of Charter Renewal AGENCY: Environmental Protection...'s Clean Air Act Advisory committee (CAAAC) will be renewed for an additional two-year period, as a... recommendations to the EPA Administrator on policy issues associated with implementation of the Clean Air Act....

  14. Motivations for self-regulation: The clean air action plan

    International Nuclear Information System (INIS)

    In the fall of 2006 the Ports of Long Beach and Los Angeles announced the Clean Air Action Plan (CAAP). Its intent was to greatly accelerate emissions reductions from port activities. The CAAP was unprecedented in several ways: it was a voluntary agreement between two competing ports; it was achieved with the cooperation of local, state and federal agencies; it promised large particulate emissions reductions along with continued port growth, and it had a price tag of $2.1 billion. What explains the Ports’ decision to implement the CAAP? We conduct a case study to explore alternative explanations for the CAAP. Using data from interviews, media, and the history of events leading up to the CAAP, we find that the CAAP was a strategic response to social and political pressures that had built up over the previous decade. Its intent was to respond to local concerns and reduce opposition to port growth. The CAAP represents an example of the potential of voluntary efforts to solve environmental problems. - Highlights: • We conduct a case study of self-regulation for emissions reduction at seaports in Southern California. • We examine motivations for implementing the Clean Air Action Plan. • We find that social and political pressures were the main motivators, with regulatory threats a contributing factor. • The Clean Air Action Plan is a powerful example of the potential of voluntary strategies

  15. Ionization Impact on the Air Cleaning Efficiency in the Interior

    Directory of Open Access Journals (Sweden)

    Černecký Jozef

    2015-08-01

    Full Text Available The paper deals with ionization impact on efficient cleaning of air in a measuring chamber which has been cleaned and closed against any outer impacts (e.g. impurities, dust from another room, human odours. Smoking has an impact on the number of positive and negative ions including the concentration of particulate matter PM10. We investigated the ion concentration according to the presence of cigarette smoke in the room and according to the change of lit cigarette distance from the supply of ionized air. Due to the experiment there was simulated smoking at the relative air humidity φ = 37 % and φ = 39 % and temperature of 20 °C in the room. Increased PM10 concentrations were caused only by cigarette smoke pollution or more precisely by artificially created higher humidity in the measuring room excluding ambient environment impacts. The aim of the experiments was to prove influence of ionization on the elimination of cigarette smoke. The measurements showed that the highest efficiency of PM10 particulate removal was achieved when the distance of smoking cigarettes from ionization source was 3 m and the air humidity was 39 %. The consequent increase of the distance of smoking cigarettes from the ionization source significantly decreased the efficiency of particle removal. The difference between ionized and natural air is minimal at the bigger distance.

  16. Clean air: Level the NOX playing field for all fuels

    International Nuclear Information System (INIS)

    In the Northeast and other non attainment areas, a level playing field NOx standard that applies to electric utilities and other major sources would offer numerous benefits, including: (1) Lower the risk of having to expend billions of dollars of refinery retrofit costs which will lead to much higher gasoline prices at the pump, in order to comply with a California Fuel VOC standard or other very expensive VOC strategy; (2) Establish a new market potential of 1 tcf for natural gas as a generating fuel in the summertime when pipeline capacity is available, which may also lead to a higher values for natural gas, reflecting its inherently cleaner nature; (3) Provide an opportunity for the environmental community, and the natural gas, refining and utility industries, as well as the State Air and PUC regulators, to work together to demonstrate environment leadership and promote a cost-effective clean air attainment strategy; and (4) Achieve cleaner air, sooner, at a lower cost. Support of this cost effective Clean Air solution will pay big dividends. This reformulation of State ozone strategies by adopting a level playing field NOx standard is both environmentally effective to attain the air quality health standards, and a least cost compliance strategy for regional economies

  17. Clean air and energy: from conflict to reconciliation

    International Nuclear Information System (INIS)

    Unconstrained energy resource development in the Rocky Mountain west is likely to threaten the environment and the health and well-being of the people. Impacts may be associated with visibility degradation, toxic concentrations of gases, and deposition of acidic or toxic substances. Because the possible benefits of energy development in the region are very large, there is great concern that constraints imposed by air quality regulation may preclude the use of important resources or make unduly expensive energy produced from the region. The conflict between energy and clean air in the region is exacerbated by non-energy sources, such as copper smelters and urban areas, that already pose significant environmental threats. The hard policy question is not how to preserve clean air resources or how to develop energy but how to achieve and balance both goals. The effects and regulatory costs and benefits of air pollution control are discussed, and policy directions to protect air quality while pursuing energy development are presented

  18. 76 FR 30604 - Approval of the Clean Air Act, Section 112(l), Authority for Hazardous Air Pollutants...

    Science.gov (United States)

    2011-05-26

    ... AGENCY 40 CFR Part 63 Approval of the Clean Air Act, Section 112(l), Authority for Hazardous Air Pollutants: Perchloroethylene Air Emission Standards for Dry Cleaning Facilities: State of Maine Department... substitution for the amended National Emissions Standards for Hazardous Air Pollutants for...

  19. An automated cleaning system for hospitals

    OpenAIRE

    Griffin, Colin

    2009-01-01

    Insufficient hygienic practices in Irish hospitals coupled with one of the highest number of reported cases of MRSA in Europe have highlighted the need for solutions to aid in the task of cleaning. This automated cleaning system consisted of two robots: a core robot developed separately with navigational and task scheduling capabilities integrated. The cleaning task was carried out by making use of a commercially available Roomba vacuum cleaner which had been adapted to operate in conju...

  20. Proceedings of the clean air and climate change summit

    International Nuclear Information System (INIS)

    The Clean Air Partnership was established in the Greater Toronto Area (GTA) over 10 years ago to work on issues related to air pollution and climate change. This summit presented details of the partnership's municipal activities and provided an outline of various projects conducted to reduce air pollution, increase the use of green energy, and encourage residents to reduce their ecological footprint. Climate change was discussed in relation to the recent economic crisis and recently discovered problems related to ocean acidification. The International Energy Agency (IEA) annual report was discussed in relation to peak oil and future economic crises. Advancements in green energy policy in Ontario were outlined. Sustainable housing and renewable energy projects in Germany were presented along with successful urban designs in Melbourne, New York City, and Denver. The GTA-CAC inter-governmental declaration on clean air was discussed, and an interim progress report was presented. The summit concluded with a video presentation of a collaborative artistic piece about climate change and the Arctic. 11 figs.

  1. Keeping the Air Clean and Safe: An Anthrax Smoke Detector

    Science.gov (United States)

    2005-01-01

    Scientists at work in the Planetary Protection division at NASA s Jet Propulsion Laboratory (JPL) sterilize everything before blasting it to the Red Planet. They take great pains to ensure that all spacecraft are void of bacterial life, especially the microscopic bacteria that can live hundreds of years in their spore states. No one is quite sure what Earthly germs would do on Mars, but scientists agree that it is safest to keep the Martian terrain as undisturbed as possible. Errant Earth germs would also render useless the instruments placed on exploration rovers to look for signs of life, as the life that they registered would be life that came with them from Earth. A team at JPL, headed by Dr. Adrian Ponce, developed a bacterial spore-detection system that uses a simple and robust chemical reaction that visually alerts Planetary Protection crews. It is a simple air filter that traps micron-sized bacterial spores and then submits them to the chemical reaction. When the solution is then viewed under an ultraviolet light, the mixture will glow green if it is contaminated by bacteria. Scientists can then return to the scrubbing and cleaning stages of the sterilization process to remove these harmful bacteria. The detection system is the space-bound equivalent of having your hands checked for cleanliness before being allowed to the table; and although intended to keep terrestrial germs from space, this technology has awesome applications here on Mother Earth. The bacterial spore-detection unit can recognize anthrax and other harmful, spore-forming bacteria and alert people of the impending danger. As evidenced in the anthrax mailings of fall 2001 in the United States, the first sign of anthrax exposure was when people experienced flu-like symptoms, which unfortunately, can take as much as a week to develop after contamination. Anthrax cost 5 people their lives and infected 19 others; and the threat of bioterrorism became a routine concern, with new threats popping up

  2. Air toxics provisions of the Clean Air Act: Potential impacts on energy

    Energy Technology Data Exchange (ETDEWEB)

    Hootman, H.A.; Vernet, J.E.

    1991-11-01

    This report provides an overview of the provisions of the Clean Air Act and its Amendments of 1990 that identify hazardous air pollutant (HAP) emissions and addresses their regulation by the US Environmental Protection Agency (EPA). It defines the major energy sector sources of these HAPs that would be affected by the regulations. Attention is focused on regulations that would cover coke oven emissions; chromium emission from industrial cooling towers and the electroplating process; HAP emissions from tank vessels, asbestos-related activities, organic solvent use, and ethylene oxide sterilization; and emissions of air toxics from municipal waste combustors. The possible implications of Title III regulations for the coal, natural gas, petroleum, uranium, and electric utility industries are examined. The report discusses five major databases of HAP emissions: (1) TRI (EPA`s Toxic Release Inventory); (2) PISCES (Power Plant Integrated Systems: Chemical Emissions Studies developed by the Electric Power Research Institute); (3) 1985 Emissions Inventory on volatile organic compounds (used for the National Acid Precipitation Assessment Program); (4) Particulate Matter Species Manual (EPA); and (5) Toxics Emission Inventory (National Aeronautics and Space Administration). It also offers information on emission control technologies for municipal waste combustors.

  3. Air toxics provisions of the Clean Air Act: Potential impacts on energy

    Energy Technology Data Exchange (ETDEWEB)

    Hootman, H.A.; Vernet, J.E.

    1991-11-01

    This report provides an overview of the provisions of the Clean Air Act and its Amendments of 1990 that identify hazardous air pollutant (HAP) emissions and addresses their regulation by the US Environmental Protection Agency (EPA). It defines the major energy sector sources of these HAPs that would be affected by the regulations. Attention is focused on regulations that would cover coke oven emissions; chromium emission from industrial cooling towers and the electroplating process; HAP emissions from tank vessels, asbestos-related activities, organic solvent use, and ethylene oxide sterilization; and emissions of air toxics from municipal waste combustors. The possible implications of Title III regulations for the coal, natural gas, petroleum, uranium, and electric utility industries are examined. The report discusses five major databases of HAP emissions: (1) TRI (EPA's Toxic Release Inventory); (2) PISCES (Power Plant Integrated Systems: Chemical Emissions Studies developed by the Electric Power Research Institute); (3) 1985 Emissions Inventory on volatile organic compounds (used for the National Acid Precipitation Assessment Program); (4) Particulate Matter Species Manual (EPA); and (5) Toxics Emission Inventory (National Aeronautics and Space Administration). It also offers information on emission control technologies for municipal waste combustors.

  4. Air toxics provisions of the Clean Air Act: Potential impacts on energy

    International Nuclear Information System (INIS)

    This report provides an overview of the provisions of the Clean Air Act and its Amendments of 1990 that identify hazardous air pollutant (HAP) emissions and addresses their regulation by the US Environmental Protection Agency (EPA). It defines the major energy sector sources of these HAPs that would be affected by the regulations. Attention is focused on regulations that would cover coke oven emissions; chromium emission from industrial cooling towers and the electroplating process; HAP emissions from tank vessels, asbestos-related activities, organic solvent use, and ethylene oxide sterilization; and emissions of air toxics from municipal waste combustors. The possible implications of Title III regulations for the coal, natural gas, petroleum, uranium, and electric utility industries are examined. The report discusses five major databases of HAP emissions: (1) TRI (EPA's Toxic Release Inventory); (2) PISCES (Power Plant Integrated Systems: Chemical Emissions Studies developed by the Electric Power Research Institute); (3) 1985 Emissions Inventory on volatile organic compounds (used for the National Acid Precipitation Assessment Program); (4) Particulate Matter Species Manual (EPA); and (5) Toxics Emission Inventory (National Aeronautics and Space Administration). It also offers information on emission control technologies for municipal waste combustors

  5. Air classification: Potential treatment method for optimized recycling or utilization of fine-grained air pollution control residues obtained from dry off-gas cleaning high-temperature processing systems.

    Science.gov (United States)

    Lanzerstorfer, Christof

    2015-11-01

    In the dust collected from the off-gas of high-temperature processes, usually components that are volatile at the process temperature are enriched. In the recycling of the dust, the concentration of these volatile components is frequently limited to avoid operation problems. Also, for external utilization the concentration of such volatile components, especially heavy metals, is often restricted. The concentration of the volatile components is usually higher in the fine fractions of the collected dust. Therefore, air classification is a potential treatment method to deplete the coarse material from these volatile components by splitting off a fines fraction with an increased concentration of those volatile components. In this work, the procedure of a sequential classification using a laboratory air classifier and the calculations required for the evaluation of air classification for a certain application were demonstrated by taking the example of a fly ash sample from a biomass combustion plant. In the investigated example, the Pb content in the coarse fraction could be reduced to 60% by separation of 20% fines. For the non-volatile Mg the content was almost constant. It can be concluded that air classification is an appropriate method for the treatment of off-gas cleaning residues. PMID:26268600

  6. DRY CLEANING OF COAL WITH AIR DENSE MEDIUM FLUIDIZED BED

    Institute of Scientific and Technical Information of China (English)

    陈清如; 杨毅; 余智敏; 李建明

    1990-01-01

    This paper deals with the experimental study of dry cleaning of coal with air dense medium fluidized bed. This technique opens up an efficient way of coal separation for vast areas in the country where water resources are in short supply or coals tend to slime seriously in wet process. Tests show that it can separate any kind of coal (6--50mm) efficiently. The probable error E, can reach 0.05--0.08. The separating density can be adjusted in the range of 1.0--2.0 g/cm3. This technique brings about enormous economic benifits.

  7. Key Technology and Experimental Results of the Clean Air Heated Facility for Supersonic Combustion

    Institute of Scientific and Technical Information of China (English)

    ZHONG Zipeng; SONG Wenyan; LE Jialing

    2009-01-01

    The scramjet, which is the propulsion of hypersonic vehicle, has become the focus in many military developed countries. The ground tests play an important role in the research of scramjet. There is defect of test medium contamination (the thermochemical characteristic of the ground test medium is different from that of the flight medium) in existing ground test facilities for scramjet combustor experiment. To solve the problem of test medium contamination, the first clean air heated facility of China for scramjet combustor experiment is designed. The key technology of designing the clean air heated facility is summarized. By using bypass duct, combustor model is protected from high temperature. To reduce the switching time between main duct and bypass duct, solenoid valve and water-cooled system were used. Having centrosymmetric structure, the heat radiating area of the facility and heat loss of the facility are much lower than others. Clean air heated facility is adopted to conduct experiment, which is the first experiment of China in clean air inflow, research on hydrogen-fueled and ethylene-fueled ignition and combustion for scramjet combustor at different equivalence ratio. Successful ignition and sustained combustion of hydrogen has been achieved. Successful ethylene ignition and sustained main stream combustion is achieved with normal fuel injection and taking hydrogen as pilot flame. Experiment result shows that the wall pressure of combustor model rises when the equivalence ratio of hydrogen rises. As the wall pressure of combustor model rises, the pressure disturbance influences the shock train in the upstream.

  8. Toronto 2001 Inter-governmental Declaration on Clean Air

    International Nuclear Information System (INIS)

    This formal declaration commits the municipalities in the Greater Toronto Area, the provincial government of Ontario, and the federal government in Ottawa to undertake certain specific actions to improve air quality in their respective areas of jurisdiction, recognizing the validity of claims made by experts in numerous studies, linking air pollution to premature deaths, illnesses and hospitalization in major Canadian cities. The declaration also recognizes the validity of scientific claims as to the relationship between solar radiation, ambient heat, ground level ozone and global climate change, and the role played in air pollution by fossil fuel combustion. The Declaration calls for cooperation of all governments operating in the Greater Toronto Area to take inter-governmental actions to improve air quality by following up on key issues identified at annual Summits and by supporting the planning of future Summits, by working together with the Toronto Organizing Committee for the Olympic Games to ensure that the 2008 Olympic Games will contribute to a legacy of clean air for the Toronto region, and by implementing a social marketing campaign to help householders reduce both home energy use and vehicle kilometres travelled by 20 per cent. Beyond these inter-governmental commitments, special commitments of individual municipalities, and the provincial and federal governments also form part of the Declaration

  9. Evaluating impacts of Clean Air Act compliance strategies

    International Nuclear Information System (INIS)

    The Clean Air Act Amendments of 1990 requires that by the year 2000, US SO2 emissions must be reduced by 10 million tons. This requirement will have significant impact on coal-fired electric utilities. As a result, most utilities are currently evaluating numerous compliance options, including buying allowances, coal cleaning/blending/switching, and flue gas scrubbing. Moreover, each utility must address its own unique circumstances with regard to competition, efficiency, capital expenditures, reliability, etc. and many utilities may choose a combination of compliance options to simultaneously satisfy their environmental, performance, and financial objectives. The Coal Quality Expert, which is being developed under a clean coal technology project funded by US DOE and EPRI, will predict the economic, operational, and environmental benefits of using higher-quality coals and provides an assessment of the merits of various post-combustion control technologies for specific utility applications. This paper presents background on how utilities evaluate their compliance options, and it describes how the Coal Quality Expert could be used for such evaluations in the future to assure that each utility can select the best combination of coal specifications and emission control technologies to meet its compliance objectives

  10. The high efficiency steel filters for nuclear air cleaning

    International Nuclear Information System (INIS)

    We have, in cooperation with industry, developed high-efficiency filters made from sintered stainless-steel fibers for use in several air-cleaning applications in the nuclear industry. These filters were developed to overcome the failure modes in present high-efficiency particulate air (HEPA) filters. HEPA filters are made from glass paper and glue, and they may fail when they get hot or wet and when they are overpressured. In developing our steel filters, we first evaluated the commercially available stainless-steel filter media made from sintered powder and sintered fiber. The sintered-fiber media performed much better than sintered-powder media, and the best media had the smallest fiber diameter. Using the best media, we then built prototype filters for venting compressed gases and evaluated them in our automated filter tester. 12 refs., 20 figs

  11. High efficiency steel filters for nuclear air cleaning

    International Nuclear Information System (INIS)

    The authors have, in cooperation with industry, developed high-efficiency filters made from sintered stainless-steel fibers for use in several air-cleaning applications in the nuclear industry. These filters were developed to overcome the failure modes in present high-efficiently particulate air (HEPA) filters. HEPA filters are made from glass paper and glue, and they may fail when they get hot or wet and when they are overpressured. In developing steel filters, they first evaluated the commercially available stainless-steel filter media made from sintered powder and sintered fiber. The sintered-fiber media performed much better than sintered-powder media, and the best media had the smallest fiber diameter. Using the best media, prototype filters were then built for venting compressed gases and evaluated in their automated filter tester

  12. Effect of Air Cleaning Technologies in Conjunction With the Use of Rotary Heat Exchangers in Residential Buildings

    DEFF Research Database (Denmark)

    Afshari, Alireza; Bergsøe, Niels Christian; Ekberg, Lars

    2013-01-01

    This study is part of a research project concerning the possibilities of applying efficient air cleaning technologies using rotary heat exchanger in residential buildings. The purpose of this project was to identify and adapt new air-cleaning technologies for implementation in HVAC systems...... with rotary air-to-air heat exchangers. For this purpose, a mechanical filter with low pressure drop and a 4 cm thick activated carbon filter were selected for testing in a laboratory environment. The measurements included testing of the filters, separately and combined, in a ductwork to study the efficiency...

  13. Can commonly-used fan-driven air cleaning technologies improve indoor air quality? A literature review

    DEFF Research Database (Denmark)

    Zhang, Yinping; Mo, Jinhan; Li, Yuguo;

    2011-01-01

    America, and Asia with expertise in air cleaning, aerosol science, medicine, chemistry and ventilation. The effects on health were not examined. Over 26,000 articles were identified in major literature databases; 400 were selected as being relevant based on their titles and abstracts by the first two......-term performance and proper maintenance. (3) The existing data make it difficult to extract information such as Clean Air Delivery Rate (CADR), which represents a common benchmark for comparing the performance of different air cleaning technologies. (4) To compare and select suitable indoor air cleaning devices...

  14. CO2 (dry ice) cleaning system

    Science.gov (United States)

    Barnett, Donald M.

    1995-01-01

    Tomco Equipment Company has participated in the dry ice (solid carbon dioxide, CO2) cleaning industry for over ten years as a pioneer in the manufacturer of high density, dry ice cleaning pellet production equipment. For over four years Tomco high density pelletizers have been available to the dry ice cleaning industry. Approximately one year ago Tomco introduced the DI-250, a new dry ice blast unit making Tomco a single source supplier for sublimable media, particle blast, cleaning systems. This new blast unit is an all pneumatic, single discharge hose device. It meters the insertion of 1/8 inch diameter (or smaller), high density, dry ice pellets into a high pressure, propellant gas stream. The dry ice and propellant streams are controlled and mixed from the blast cabinet. From there the mixture is transported to the nozzle where the pellets are accelerated to an appropriate blasting velocity. When directed to impact upon a target area, these dry ice pellets have sufficient energy to effectively remove most surface coatings through dry, abrasive contact. The meta-stable, dry ice pellets used for CO2 cleaning, while labeled 'high density,' are less dense than alternate, abrasive, particle blast media. In addition, after contacting the target surface, they return to their equilibrium condition: a superheated gas state. Most currently used grit blasting media are silicon dioxide based, which possess a sharp tetrahedral molecular structure. Silicon dioxide crystal structures will always produce smaller sharp-edged replicas of the original crystal upon fracture. Larger, softer dry ice pellets do not share the same sharp-edged crystalline structures as their non-sublimable counterparts when broken. In fact, upon contact with the target surface, dry ice pellets will plastically deform and break apart. As such, dry ice cleaning is less harmful to sensitive substrates, workers and the environment than chemical or abrasive cleaning systems. Dry ice cleaning system

  15. Nuclear track membranes in devices for air cleaning personnel viability support and biotechnological protection

    International Nuclear Information System (INIS)

    A brief review of designs development in the field of nuclear track membranes application for air cleaning and keeping clean zones and technological volumes sterile, carried out in Nuclear Reaction Laboratory of JINR, have been presented. Several technical solutions have been shown. That are: find air cleaning filter, local clean work place, gas exchanger, diffusion respirator, bio-technological protection of fermenter and membrane bioreactor. 21 refs, 12 figs

  16. Clean-air video will interest MDs who treat patients with allergies, respiratory problems.

    Science.gov (United States)

    Rafuse, J

    1996-03-15

    Canada Mortgage and Housing Corporation wants physicians to help raise public awareness abut the importance of indoor air quality to health. Physicians across Canada are being sent a colourful poster that calls attention to indoor air pollution and ways to make a home healthier, included are order forms for the Clean Air Guide and a companion video, This Clean House. PMID:8634972

  17. Clean-air video will interest MDs who treat patients with allergies, respiratory problems.

    OpenAIRE

    Rafuse, J

    1996-01-01

    Canada Mortgage and Housing Corporation wants physicians to help raise public awareness abut the importance of indoor air quality to health. Physicians across Canada are being sent a colourful poster that calls attention to indoor air pollution and ways to make a home healthier, included are order forms for the Clean Air Guide and a companion video, This Clean House.

  18. 77 FR 46757 - Proposed Consent Decree, Clean Air Act Citizen Suit

    Science.gov (United States)

    2012-08-06

    ... INFORMATION CONTACT: David Orlin, Air and Radiation Law Office (2344A), Office of General Counsel, U.S... AGENCY Proposed Consent Decree, Clean Air Act Citizen Suit AGENCY: Environmental Protection Agency (EPA... section 113(g) of the Clean Air Act, as amended (``CAA''), notice is hereby given of a proposed...

  19. 77 FR 46756 - Proposed Consent Decree, Clean Air Act Citizen Suit

    Science.gov (United States)

    2012-08-06

    ... above. FOR FURTHER INFORMATION CONTACT: Kendra Sagoff, Air and Radiation Law Office (2344A), Office of... AGENCY Proposed Consent Decree, Clean Air Act Citizen Suit AGENCY: Environmental Protection Agency (EPA... section 113(g) of the Clean Air Act, as amended (``CAA'' or the ``Act''), 7413(g), notice is hereby...

  20. Wet-air oxidation cleans up black wastewater

    Energy Technology Data Exchange (ETDEWEB)

    1993-09-01

    Sterling Organics produces the analgesic paracetamol (acetaminophen) at its Dudley, England, plant. The wastewater from the batch process contains intermediates such as para-aminophenol (PAP) and byproducts such as thiosulfates, sulfites and sulfides. To stay ahead of increasingly strict environmental legislation, Sterling Organics installed a wet-air oxidation system at the Dudley facility in August 1992. The system is made by Zimpro Environmental Inc. (Rothschild, Wis.). Zimpro's wet-air oxidation system finds a way around the limitations of purely chemical or physical processes. In the process, compressed air at elevated temperature and pressure oxidizes the process intermediates and byproducts and removes the color from the wastewater.

  1. Air Systems Provide Life Support to Miners

    Science.gov (United States)

    2014-01-01

    Through a Space Act Agreement with Johnson Space Center, Paragon Space Development Corporation, of Tucson, Arizona, developed the Commercial Crew Transport-Air Revitalization System, designed to provide clean air for crewmembers on short-duration space flights. The technology is now being used to help save miners' lives in the event of an underground disaster.

  2. The importance of damper drive performance for clean air

    International Nuclear Information System (INIS)

    Amendments to the U.S. Federal Clean Air Act require petroleum refineries and other industries to examine every aspects of their process heating operations in order to reduce cumulative nitrogen oxide emissions from their plants. It has been found that changing the final damper control elements to more reliable and accurate damper drives greatly improves the combustion of air and flue gases and reduces tramp air from entering furnaces. This paper discusses the increasing importance of precise damper drives in nitrogen oxides reduction efforts, and the challenges involved in effecting good damper control. It also provides some technical details about final control drives, manufactured by TYPE K Damper Drives, a division of Controls International Inc., that thrive in environments of extreme temperatures, heavy vibration and fly ash, while providing continuous duty service with smooth, accurate and repeatable damper positioning. Case history of an Ontario oil refinery installing several damper drives designed by TYPE K, indicating high level of nitrogen oxides reduction is described to illustrate the importance and the advantages of damper control drives designed by this firm. In addition to meeting regulatory requirements, additional benefits include improved product quality and safety levels, combined with lower maintenance expenses. photos

  3. Chicago Clean Air, Clean Water Project: Environmental Monitoring for a Healthy, Sustainable Urban Future

    Energy Technology Data Exchange (ETDEWEB)

    none, none; Tuchman, Nancy [Institute of Environmental Sustainability (IES), Chicago, IL (United States)

    2015-11-11

    The U.S. Department of Energy awarded Loyola University Chicago and the Institute of Environmental Sustainability (IES) $486,000.00 for the proposal entitled “Chicago clean air, clean water project: Environmental monitoring for a healthy, sustainable urban future.” The project supported the purchase of analytical instruments for the development of an environmental analytical laboratory. The analytical laboratory is designed to support the testing of field water and soil samples for nutrients, industrial pollutants, heavy metals, and agricultural toxins, with special emphasis on testing Chicago regional soils and water affected by coal-based industry. Since the award was made in 2010, the IES has been launched (fall 2013), and the IES acquired a new state-of-the-art research and education facility on Loyola University Chicago’s Lakeshore campus. Two labs were included in the research and education facility. The second floor lab is the Ecology Laboratory where lab experiments and analyses are conducted on soil, plant, and water samples. The third floor lab is the Environmental Toxicology Lab where lab experiments on environmental toxins are conducted, as well as analytical tests conducted on water, soil, and plants. On the south end of the Environmental Toxicology Lab is the analytical instrumentation collection purchased from the present DOE grant, which is overseen by a full time Analytical Chemist (hired January 2016), who maintains the instruments, conducts analyses on samples, and helps to train faculty and undergraduate and graduate student researchers.

  4. Impact of clean air legislation on the petroleum industry

    International Nuclear Information System (INIS)

    As the 1990s begin, the petroleum refining and marketing industry faces an unprecedented number of environmental issues that, combined, will bring major changes in the fundamentals of the business by the turn of the century. The following background on the history of environmentally driven change in the oil business provides a broad view of current environmental laws and regulations, while addressing timing and general impacts on the downstream segment. It will then focus on the Clean Air Act of 1990, providing information on the range of areas this comprehensive legislative initiative will regulate. Finally, the discussion narrows to the mobile source provisions of the act. It is through this section that the most foundational changes in our business will occur. In this paper the nature of those changes are discussed, and a short list of issues with potential for significant impact on a global basis are covered

  5. Clean Air for London (CLEARFLO) Final Campaign Summary

    Energy Technology Data Exchange (ETDEWEB)

    Worsnop, D. R. [Aerodyne Research, Inc., Billerica, MA (United States); Williams, L. R. [Aerodyne Research, Inc., Billerica, MA (United States); Herndon, S. C. [Aerodyne Research, Inc., Billerica, MA (United States); Dubey, M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Ng, N. L. [Georgia Inst. of Technology, Atlanta, GA (United States); Thornton, J. [Univ. of Washington, Seattle, WA (United States); Knighton, B. [Montana State Univ., Bozeman, MT (United States); Coulter, R. [Argonne National Lab. (ANL), Argonne, IL (United States); Prévôt, Ash [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    2016-03-01

    This field campaign funded the participation of scientists from seven different research groups and operated over thirty instruments during the Winter Intensive Operating Period (January-February 2012) of the Clean Air for London (ClearfLo) campaign. The campaign took place at a rural site in Detling, UK, 45 kilometers southeast of central London. The primary science questions for the ClearfLo winter IOP (intensive operational periods) were: 1) “what is the urban increment of particulate matter (PM) and other pollutants in the greater London area?” and 2) “what is the contribution of solid fuel use for home heating to wintertime PM?” An additional motivation for the Detling measurements was the question of whether coatings on black carbon particles enhance absorption.

  6. 78 FR 16630 - Clean Air Act Grant: South Coast Air Quality Management District; Opportunity for Pubic Hearing

    Science.gov (United States)

    2013-03-18

    ... AGENCY 40 CFR Part 35 Clean Air Act Grant: South Coast Air Quality Management District; Opportunity for... Quality Management District (SCAQMD) in support of its continuing air program under section 105 of the... expenditures in the programs of the South Coast Air Quality Management District. The shortfall stems from...

  7. Air Quality System (AQS)

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Air Quality System (AQS) database contains measurements of air pollutant concentrations from throughout the United States and its territories. The measurements...

  8. Cleaning of process and utility systems

    International Nuclear Information System (INIS)

    The cleaning of the process and utility equipment and systems forms part of the underlying strategy of planning and implementation. General observation shows that planning is the first essential element to a successful project. A prerequisite to good planning is establishing the goals and objectives at the very outset of the Abandonment Planning. These goals and objectives must be measurable against preestablished criteria so that the project can be evaluated to establish the level of success. Good planning can be viewed as a series of hurdles that one must clear to achieve the pre-set goals and objectives. Understanding of the legal, safety, environmental and legislative requirements allows the perimeters and constraints to be established before the final implementation of the, ''CLEANING OF PROCESS AND UTILITY EQUIPMENT AND SYSTEMS'' activities. The very subject of ''CLEANING OF PROCESS AND UTILITY EQUIPMENT AND SYSTEMS'' that may be considered straight forward, because some of these activities often form part of the normal platform operations performed from time to time on these systems. Before implementation of these activities, there must be an understanding of the ground rules and terminology used together with the resultant implications. A question that demonstrates the inherent problems, what does the term ''Clean'' mean? A limited list has been compiled to give some examples of what the dictionary defines the term clean to be; NOT DIRTY; UN-POLLUTED; DECONTAMINATED; STAINLESS; UNCONTAMINATED; SPOTLESS; VIRGIN; UNSTAINED; UNADULTERATED; STERILE; Liaison with Government departments during recent planning activities established a consensus for understanding the term ''Clean'' so that unreasonable expectation with regards to the level of cleanliness would not be greater than that which is practicable

  9. Implementation of the clean air strategy for Alberta

    Energy Technology Data Exchange (ETDEWEB)

    Sandhu, H.S.; Angle, R.P. [Alberta Dept. of Environmental Protection, Alberta (Canada); Kelly, M. [Clean Air Strategic Alliance, Alberta (Canada)

    1995-12-31

    Air quality and its effects on the environment and human health have received considerable attention during the last three decades in Alberta, Canada. Among the issues receiving a high priority are acid deposition, smog and global warming. There are various sources of emissions to Alberta`s atmosphere, many of which relate to the extraction, processing, and burning of fossil fuels; pulp and paper manufacture; and transportation. There are also natural sources of contaminants, such as particulates from forest fires and methane from bogs. The extraction, processing and combustion of fossil fuels play an important role in Alberta`s economy. The province produces over 80 % of the oil and natural gas in Canada, and nearly half the coal. Low sulphur coal is used in power plants to supply more than 90 % of the electricity used in this province by nearly three million people. As a result, Alberta is responsible for about 27 % of the CO{sub 2}, 23 % of the nitrogen oxides, and 16 % of the SO{sub 2} emissions generated in Canada. Alberta`s air quality is monitored by the Government of Alberta at nine continuous, eight intermittent, over 250 static, and 12 precipitation monitoring stations. Parameters such as carbon monoxide, oxides of nitrogen, sulphur dioxide, particulates, and ion-content of precipitation are measured. Industry operates a large number of ambient and static SO{sub 2} and H{sub 2}S monitoring stations across Alberta, with monitoring costs estimated at 56-80 million USD annually. The unique features of the Clean Air Strategy for Alberta (CASA) have already been published elsewhere. This presentation discusses the mechanism and progress on its implementation. (author)

  10. 76 FR 65722 - Notification of Two Public Teleconferences; Clean Air Scientific Advisory Committee

    Science.gov (United States)

    2011-10-24

    ... AGENCY Notification of Two Public Teleconferences; Clean Air Scientific Advisory Committee AGENCY... Clean Air Scientific Advisory Committee (CASAC) to discuss its draft review of EPA's Integrated Science.../casac . Any inquiry regarding EPA's Integrated Science Assessment for Lead (First External Review...

  11. 75 FR 18239 - Notice of Proposed Consent Decree Under the Clean Air Act

    Science.gov (United States)

    2010-04-09

    ... of Proposed Consent Decree Under the Clean Air Act Notice is hereby given that on March 31, 2010, two proposed Consent Decrees were lodged. United States et al. v. Shell Chemical LP, Civil Action No. 4:10-cv... District Court for the District of Puerto Rico. The Consent Decrees in these Clean Air Act...

  12. 14 CFR 1274.926 - Clean Air-Water Pollution Control Acts.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 5 2010-01-01 2010-01-01 false Clean Air-Water Pollution Control Acts...-Water Pollution Control Acts. Clean Air-Water Pollution Control Acts July 2002 If this cooperative... Violating Facilities” published pursuant to 40 CFR 15.20. By acceptance of a cooperative agreement in...

  13. 45 CFR 2543.86 - Clean Air Act and the Federal Water Pollution Control Act.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 4 2010-10-01 2010-10-01 false Clean Air Act and the Federal Water Pollution... Water Pollution Control Act. Contracts and subgrants of amounts in excess of $100,000 shall contain a... regulations issued pursuant to the Clean Air Act (42 U.S.C. 7401 et seq.) and the Federal Water...

  14. RECLAIMing Air, Redefining Democracy : : A History of the Regional Clean Air Incentives Market, Environmental Justice, and Risk, 1960 - present

    OpenAIRE

    Tribbett, Krystal L.

    2014-01-01

    Depending on whom you ask, the Regional Clean Air Incentive Market (RECLAIM), the nation's first regional smog market, is either a revolutionary approach to cleaning the air of the South Coast Air Basin, the most polluted region in the country, or a failed social experiment that put the interests of business and the marketplace above public health. In its original iteration, RECLAIM rules were intended to produce emissions reductions consistent with the command-and-control approach to complia...

  15. Evaluating The Operation Of Three Air Cleaners Working Individually In A Clean Room

    DEFF Research Database (Denmark)

    Ardkapan, Siamak Rahimi; Afshari, Alireza; Bergsøe, Niels Christian;

    2011-01-01

    The use of portable air cleaners is becoming increasingly popular in many countries including Denmark. Portable air cleaners are known for not only removing but also generating particles and gases. To clarify this, three air cleaning technologies were evaluated. They were nonthermal plasma......, photochemical air purifier and corona discharge ionizer. The concentrations of ultrafine particles, ozone and total volatile organic compounds were measured both in a duct and in a clean room. It was found that the studied air cleaning technologies increased the ozone level in the clean room and the duct. The...... increase of ozone level in the clean room was more than that was measured in the duct. Additionally, it was found that the number of ultrafine particles in the room increased due to the generated ozone. The number of generated particles changed with the season. The study leads to the recommendation that...

  16. In-Water Hull Cleaning & Filtration System

    Science.gov (United States)

    George, Dan

    2015-04-01

    Dan George R & D Mining Technology LinkedIn GRD Franmarine have received the following prestigious awards in 2014 for their research & development of an in-water hull cleaning and filtration system "The Envirocart: Golden Gecko Award for Environmental Excellence; WA Innovator of the Year - Growth Sector; Department of Fisheries - Excellence in Marine Biosecurity Award - Innovation Category; Lloyd's List Asia Awards - Environmental Award; The Australian Innovation Challenge - Environment, Agriculture and Food Category; and Australian Shipping and Maritime Industry Award - Environmental Transport Award. The Envirocart developed and patented by GRD Franmarine is a revolutionary new fully enclosed capture and containment in-water hull cleaning technology. The Envirocart enables soft Silicon based antifouling paints and coatings containing pesticides such as Copper Oxide to be cleaned in situ using a contactless cleaning method. This fully containerised system is now capable of being deployed to remote locations or directly onto a Dive Support Vessel and is rated to offshore specifications. This is the only known method of in-water hull cleaning that complies with the Department of Agriculture Fisheries and Forestry (DAFF) and Department of Fisheries WA (DoF) Guidelines. The primary underwater cleaning tool is a hydraulically powered hull cleaning unit fitted with rotating discs. The discs can be fitted with conventional brushes for glass or epoxy based coatings or a revolutionary new patented blade system which can remove marine biofouling without damaging the antifouling paint (silicone and copper oxide). Additionally there are a patented range of fully enclosed hand cleaning tools for difficult to access niche areas such as anodes and sea chests, providing an innovative total solution that enables in-water cleaning to be conducted in a manner that causes no biological risk to the environment. In full containment mode or when AIS are present, material is pumped

  17. Clean air renewable energy (CARE) coalition : a case study

    International Nuclear Information System (INIS)

    This paper highlights the opportunity for new partnerships between business and non-governmental organizations in the field of sustainable development through the growing convergence of interests. The authors also briefly describe both Suncor Energy and the Pembina Institute for Appropriate Development stances on sustainable development. Since 1990, both organizations have collaborated on the future of the emerging renewable energy industry. Renewable energy represents an energy source diversification through the regional creation of jobs and improved air quality and associated benefits resulting from the reductions in greenhouse gas emissions. The Clean Air Renewable Energy Coalition (Coalition) was established in December 2000 in order to assess the barriers to capital investment in the renewable energy industry. It was revealed that the international community as a whole was further ahead than Canada in terms of renewable support, production and export of technology and services. Some of the challenges facing the industry are: low demand for renewables and low supply. The coalition allowed for the joint identification of desired policy changes, such as new tax incentives for renewable energy supply and demand. Efforts were made in inviting the support of industry, municipalities and environmental non governmental organizations. The list of members that have joined the coalition to date was shown. The coalition is asking for consumer green energy credit, designed for the creation of demand and the education of the general public, and producer incentives to increase supply. The proposals were explained, as well as the strategic principles underlying them. A new tax incentive was announced in the December 2001 Canadian federal budget. The authors concluded by mentioning some future opportunities and the lessons learned on the importance of the right partners, of broad-based advocacy, of targeted and focuses messages, and of evolutionary change

  18. Cleaning the air with renewable energy : briefing note

    International Nuclear Information System (INIS)

    The Clean Air Renewable Energy Coalition promotes the development of the renewable energy industry in Canada. It acknowledges the effort that the Canadian government has taken to advance investment in renewable energy, but the Coalition is concerned that these investments alone will not achieve the desired objectives without additional policy development by federal, provincial and territorial governments. This report presents an overview of 7 proposals designed to promote and advance renewable energy in Canada. The benefits of these proposals include cleaner air, improved health, engaging public and industry participation in climate change initiatives, and fostering innovation and entrepreneurship in the sector. Brief details were presented for the following 7 proposals: (1) establish a national low-impact renewable energy target for Canada, (2) increase the Wind Power Production Incentive (WPPI) to 2.7 cent per kilowatt hour to ensure appropriate investment in wind energy and harmonization with the United States, (3) extend incentive programs similar to the WPPI to other renewable energy technologies, (4) work with other levels of government to implement policy mechanisms to meet the recommended national renewable energy target, (5) expand the Market Incentive Program (MIP) funding to 30 million dollars per year to 2012 and consult with the provinces and territories to develop a broad-based consumer green energy rebate and education program, (6) identify mechanisms to ensure a meaningful role for renewable energy to contribute to the country's climate change strategy, and (7) develop a Wind Energy Mapping and Wind Measurement Initiative. In a recent update, the Coalition states that low environmental impact renewable energy needs market recognition for its environmental and social benefits. In general, these benefits are not financially valued in energy market pricing. In addition, energy sources that impact significantly on the environment are not financially

  19. Energy efficient biological air cleaning for farm stable ventilation; Energieffektiv biologisk luftrensning til staldventilation

    Energy Technology Data Exchange (ETDEWEB)

    Groenborg Nicolaisen, C.; Hansen, Mads P.R. [Teknologisk Institut, Aarhus (Denmark); Stroem, J.; Soerensen, Keld [DXT. Danish Exergy Technology A/S, Skoerping (Denmark); Goetke, C. [Lokalenergi Aarhus, Viby J. (Denmark); Morsing, S.; Soerensen, Lars C. [SKOV A/S, Roslev (Denmark); Ladegaerd Jensen, T.; Pedersen, Poul [Videncenter for svineproduktion, Copenhagen (Denmark)

    2013-05-01

    The project has been designed to reduce energy consumption for air purification by 30% while having a payback period of maximum 3 years. The project has achieved very significant results which are far above the target. Particularly satisfying is the wide range of new components that are launched in late 2012. By implementing the newly developed system at 100% cleaning (LPC 13 ventilators and Dynamic multistep control) in relation to Best Practice (SKOV's original system with DA600 fans) in a concrete pigsty, a saving of 61% and a simple payback of 1.7 years is achieved. Similarly, it is found that the energy used for pump operation can be reduced by 37% with the new Dynamic sprinkling control. At 20% cleaning a potential saving of 15% per year and a payback period of between 0 and 5 years was found, which is dependent on the desired performance as the capacities in the bio-filter's upper capacity range between 26 thousand to 30 thousand m3 / h entails costs for an additional extraction unit in the new solution. Furthermore, the newly developed components proved highly suitable for standard installations without air cleaning where a savings potential is 53% and the payback period 1.5 years. Product-wise, the project formed the basis for the development of: 1. New energy-efficient ventilation units (LPC11, 12,13) that are suitable for air purification; 2. A new energy-saving control principle (Dynamic Multi-Step) which is particularly suitable for low-energy ventilators; 3. A new energy-saving flow measurement system for ventilating ducts (Dynamic air to the central exhaust); 4. An energy-saving pressure control in common ducts (pressure control as a function of outside temperature); 5. Proposal for a new energy-saving pump operation for sprinkling of biological filters (Dynamic sprinkling). (LN)

  20. Emissions reduction study for the Ontario Clean Air Alliance (OCAA)

    International Nuclear Information System (INIS)

    A significant portion of Ontario's total emissions of CO2, SO2 and NOx originate from Ontario Hydro's coal-fired generating stations. A study was conducted to provide the Ontario Clean Air Alliance (OCAA) with an analytic tool in the form of a computerized spreadsheet model that would simulate the cost and emissions impacts of replacing coal-fired power generation with natural gas-fired generation. The computer model was designed to assess the cost of establishing caps for Ontario's electricity-related sulphur dioxide emissions which are 25, 50, 70, and 90 per cent lower than Ontario Hydro's status quo sulphur dioxide emission cap. In the case based on the 90 per cent reduction in the SO2 cap, it was determined that the cumulative savings in SO2, CO2 and NOx and toxics emissions are 83, 51, 77 and 83 per cent respectively. The computer model is based on 'best practice' principles and conservative assumptions to ensure that the cost of gas substitution is not understated. 9 tabs., 2 appendices

  1. 78 FR 51184 - Air Pollution Control: Proposed Actions on Clean Air Act Section 105 Grant to the Lane Regional...

    Science.gov (United States)

    2013-08-20

    ... AGENCY Air Pollution Control: Proposed Actions on Clean Air Act Section 105 Grant to the Lane Regional... Lane Regional Air Protection Agency (LRAPA) in Eugene, Oregon is a result of agency wide non-selective...-selective reduction on September 30, 2011. In consideration of legislative history, the guidance...

  2. VENTILATED AIR AERODYNAMICS IN DEVICE FOR CLEANING FROM FINE-DISPERSED MOISTURE

    OpenAIRE

    V. N. Kobelev,; V. S. Ezhov; T. V. Alyabyeva

    2010-01-01

    Problem statement. The efficiency of ventilation air cleaning is defined by the time dependence of concentration of fine-dispersed moisture in environmental chamber for testing electronic products.Results and conclusions. An aerodynamic calculation technique of the element of ventilated air cleaning assembly is proposed with consideration for specific fea-tures of determination of the concentration of fine-dispersed drop-like and solid particles arriving with atmospheric air drawn by ventilat...

  3. Learning from 25 years of experience with the United States clean air act

    Energy Technology Data Exchange (ETDEWEB)

    Schulze, R.H. [Trinity Consultants Incorporated, Dallas, TX (United States)

    1995-12-31

    Twenty-five years ago, the United States embarked on a quest to attain clean air. President Nixon, in signing the Clean Air Act of 1970, defined clean air as the objective for the `70s. Although enormous progress has been made, much remains to be done. Newly constructed industry is quite clean, but many older facilities continue to operate with antiquated controls. Significant advances have been made in cleaning up the emissions from new automobiles, but two factors have impaired progress. First, cars last longer than they did in 1970, so the average age of the fleet has increased. Second, travel has increased as people have moved to the suburbs. Thus, the emission decreases from clean cars have not been as great as expected. This presentation will address some of the lessons learned from the efforts in the United States to implement clean air programs. In a large number of countries, excessively elaborate studies have been substituted for action programs. Since much is now known about air quality, fairly brief studies can define programs that should be undertaken. What may take longer is developing public support and enthusiasm for improved air quality. In most cases, it is desirable to reduce spending on studies and increase spending on devising and implementing plans, as well as effectively communicating the necessary changes to the public. Balanced spending on studies- and action programs is essential to a sound air quality control program. (author)

  4. 76 FR 30545 - Approval of the Clean Air Act, Section 112(l), Authority for Hazardous Air Pollutants...

    Science.gov (United States)

    2011-05-26

    ...), as amended by 65 FR 55810 (September 14, 2000). Under these regulations, a state air pollution... promulgated the Dry Cleaning NESHAP on September 22, 1993. See 58 FR 49354 (codified at 40 CFR part 63... promulgated amendments to the Dry Cleaning NESHAP. See 71 FR 42724, 71 FR 55280 and 73 FR 39871. In a...

  5. Evaluation of control parameters for Spray-In-Air (SIA) aqueous cleaning for shuttle RSRM hardware

    Science.gov (United States)

    Davis, S. J.; Deweese, C. D.

    1995-01-01

    HD-2 grease is deliberately applied to Shuttle Redesigned Solid Rocket Motor (RSRM) D6AC steel hardware parts as a temporary protective coating for storage and shipping. This HD-2 grease is the most common form of surface contamination on RSRM hardware and must be removed prior to subsequent surface treatment. Failure to achieve an acceptable level of cleanliness (HD-2 calcium grease removal) is a common cause of defect incidence. Common failures from ineffective cleaning include poor adhesion of surface coatings, reduced bond performance of structural adhesives, and failure to pass cleanliness inspection standards. The RSRM hardware is currently cleaned and refurbished using methyl chloroform (1,1,1-trichloroethane). This chlorinated solvent is mandated for elimination due to its ozone depleting characteristics. This report describes an experimental study of an aqueous cleaning system (which uses Brulin 815 GD) as a replacement for methyl chloroform. Evaluation of process control parameters for this cleaner are discussed as well as cleaning mechanisms for a spray-in-air process.

  6. TORR system polishes oily water clean

    International Nuclear Information System (INIS)

    The TORR (total oil recovery and remediation) system utilizes a specially patented polymer material, similar to styrofoam, which is used to get rid of non-soluble hydrocarbons from water. An application in Fort Smith, Northwest Territories, is described where it was used to recover diesel oil, which had been seeping into the groundwater over a period of 20 years. About 100,000 gallons of heating oil had leached into the water; TORR removed the non-soluble hydrocarbons, while another piece of equipment removed the soluble portions. After treatment the water tested consistently at non-detectable levels and was clean enough to be discharged into the town's sewer system. The system is considered ideal for oil spills clean-up underground, onshore, or the open sea, but it also has many potentially useful applications in industrial and oilfield applications. Water used in steam injection and water floods to produce heavy oil and SAGD applications are some of the obvious ones that come to mind. Cleaning up the huge tailings ponds at the mining and processing of oil sands, and removing diluent from water that is used to thin out bitumen in pipelines so that it can be transported to processing plants, are other promising areas of application. Several field trials to test the effectiveness of the system in these type of applications are scheduled for the summer and fall of 2002

  7. 3 CFR - State of California Request for Waiver Under 42 U.S.C. 7543(b), the Clean Air Act

    Science.gov (United States)

    2010-01-01

    ....C. 7543(b), the Clean Air Act Presidential Documents Other Presidential Documents Memorandum of January 26, 2009 State of California Request for Waiver Under 42 U.S.C. 7543(b), the Clean Air Act Memorandum for the Administrator of the Environmental Protection Agency Under the Clean Air Act (42...

  8. 40 CFR 22.34 - Supplemental rules governing the administrative assessment of civil penalties under the Clean Air...

    Science.gov (United States)

    2010-07-01

    ... administrative assessment of civil penalties under the Clean Air Act. 22.34 Section 22.34 Protection of... Clean Air Act. (a) Scope. This section shall apply, in conjunction with §§ 22.1 through 22.32, in...) of the Clean Air Act, as amended (42 U.S.C. 7413(d), 7524(c), 7545(d), and 7547(d))....

  9. Air Pollution Studies in Metromanila and Catalysis Technology Towards Clean Air Philippines

    Science.gov (United States)

    Gallardo, S. M.

    - Considerable air quality and emission data gathered in Metropolitan Manila (MM) led to the development of automobile exhaust treatment catalysts as well as their continued improvement. Findings of a 5-year (1993-1998) collaborative work on the development of base metal oxide catalysts for automobile exhaust are summarized here. One study in 1991 reveals an average 16% increase in the number of motor vehicles in MM where 16% are new and the rest are old ones. Another study in 1992 shows the CO and hydrocarbon emission levels from different types of motor vehicles in MM as a function of the age of the vehicle, type of fuel, and the operating condition. Reports of the Department of Environment and Natural Resources (DENR) and other related studies also provided data showing the quality of air in MM. Currently, there are several requirements to further improve the catalyst performance towards the reduction of NOX and to develop catalyst-sorbent for simultaneous NOX-SOX removal. This is so because of the present condition of rain acidification that is found in certain places in MM. These air quality and emission data are needed not only to establish practical emission standards for motor vehicles and the stationary industries and power plants but also in the development of technologies for air pollution control and other clean technologies for cleaner air in the country.

  10. Suitable control choices: exploring the roles of clean air suits and scrub suits in infection control

    OpenAIRE

    Abreu, Maria José

    2014-01-01

    Experts in infection control are often asked about issues related to the use of scrubs and clean air suits in the operating room (OR). So far there is no clear explanation or mandatory obligation why the surgical team has to wear clean air suits or scrub suits in ORs and, more importantly, what the main differences are between these two types of clothing. There is a general perception that the two are equal or very similar. So, what are clean air suits and scrub ...

  11. Federal-state partnership: An overview of the Clean Air Act through the 1980s

    International Nuclear Information System (INIS)

    This chapter examines the experience with Clean Air Act regulation over the past two decades as a means of understanding the multiple layers of regulatory requirements that now exist since the enactment of the 1990 Amendments to the Act. The efforts of Congress and the EPA to deal with the complexities of clean air regulation suggest several themes for the 1990s: more federal oversight, more complex regulatory issues, an emphasis on alternatives to traditional rulemaking proceedings, and a search for innovative ways to control the escalating costs of clean air regulation

  12. The Clean Coal Program's contributions to addressing the requirements of the Clean Air Act Amendments of 1990

    International Nuclear Information System (INIS)

    The purpose of this paper is to examine the potential contributions of the US Department of Energy's Clean Coal Program (CCP) to addressing the requirements of the Clean Air Act (CAA) Amendments of 1990 (CAA90). Initially funded by Congress in 1985, the CCP is a government and industry co-funded effort to demonstrate a new generation of more efficient, economically feasible, and environmentally acceptable coal technologies in a series of full- scale ''showcase'' facilities built across the country. The CCP is expected to provide funding for more than $5 billion of projects during five rounds of competition, with at least half of the funding coming from the private sector. To date, 42 projects have been selected in the first 4 rounds of the CCP. The CAA and amendments form the basis for regulating emissions of air pollutants to protect health and the environment throughout the United States. Although the origin of the CAA can be traced back to 1955, many amendments passed since that time are testimony to the iterative process involved in the regulation of air pollution. Three key components of CAA90, the first major amendments to the CAA since 1977, include mitigation measures to reduce levels of (1) acid deposition, (2) toxic air pollutants, and (3) ambient concentrations of air pollutants. This paper focuses on the timeliness of clean coal technologies in contributing to these provisions of CAA90

  13. Assessing the performance of air cleaning devices - A full-scale test method

    Energy Technology Data Exchange (ETDEWEB)

    Bastani, Arash; Haghighat, Fariborz [Department of Building, Civil, and Environmental Engineering, Concordia University, Montreal, Quebec, H3G 1M8 (Canada); Lee, Chang-Seo; Flaherty, Chris; Lakdawala, Ness [Dectron Internationale Inc., Montreal, Quebec, H4R 1R2 (Canada)

    2010-01-15

    Activated carbon filters have been used for purification of air and water in industrial applications. However, these technologies have not been applied to the non-industrial built environment in general and there is no standard to quantify or to classify the performance of these systems for in-duct mechanical system application. The development of a standard test procedure is a very timely effort, since it would create a benchmark for evaluating the contaminant reduction of these systems. A full-scale test facility was designed and constructed to investigate the removal effectiveness of commercial gas-phase air cleaning devices. The test rig was verified by conducting the system pre-qualification tests. These series of tests were designed to quantitatively verify the reliability of the test rig for gas filter application. These tests include air tightness, velocity uniformity, uniform dispersion of challenge contaminants, temperature and humidity control. This paper first describes the experimental set-up for testing of in-duct air cleaner systems and its verification, and then presents the experimental results of four different kinds of commercial gaseous filters. (author)

  14. 76 FR 5609 - Notice of Proposed Consent Decree Under the Clean Air Act

    Science.gov (United States)

    2011-02-01

    ... of Proposed Consent Decree Under the Clean Air Act Notice is hereby given that on January 26, 2011, a proposed Consent Decree was lodged with the District Court of the Virgin Islands, Division of St. Croix, in United States et al. v. HOVENSA L.L.C., Civil Action No. 1:11-cv-6. The Consent Decree in this Clean...

  15. Clean Lead Facility Inventory System user's manual

    International Nuclear Information System (INIS)

    The purpose of this user's manual is to provide instruction and guidance needed to enter and maintain inventory information for the Clean Lead Facility (CLF), PER-612. Individuals responsible for maintaining and using the system should study and understand the information provided. The user's manual describes how to properly use and maintain the CLF Inventory System. Annual, quarterly, monthly, and current inventory reports may be printed from the Inventory System for reporting purposes. Profile reports of each shipment of lead may also be printed for verification and documentation of lead transactions. The CLF Inventory System was designed on Microsoft Access version 2.0. Similar inventory systems are in use at the Idaho National Engineering Laboratory (INEL) to facilitate site-wide compilations of mixed waste data. The CLF Inventory System was designed for inventorying the clean or non-radioactive contaminated lead stored at the CLF. This data, along with the mixed waste data, will be compiled into the Idaho Mixed Waste Information (IMWI) system for reporting to the Department of Energy Idaho Office, Department of Energy Headquarters, and/or the State of Idaho

  16. Energy Systems Comparison and Clean High Tech Evolution

    OpenAIRE

    Grob, Gustav

    2010-01-01

    Humanity can be confident to survive on planet Earth in good livelihood, because 1 - there is enough clean, sustainable energy available for centuries to come 2 - these clean, sustainable energy systems are competitive with finite polluting systems 3 - decentralized, clean sustainable energy conversion will be growing world-wide 4 - environmental impacts can be avoided with clean, sustainable energy systems 5 - mineral resources can be conserved for future generations and must not be burnt an...

  17. Precision Cleaning Verification of Fluid Components by Air/Water Impingement and Total Carbon Analysis

    Science.gov (United States)

    Barile, Ronald G.; Fogarty, Chris; Cantrell, Chris; Melton, Gregory S.

    1995-01-01

    NASA personnel at Kennedy Space Center's Material Science Laboratory have developed new environmentally sound precision cleaning and verification techniques for systems and components found at the center. This technology is required to replace existing methods traditionally employing CFC-113. The new patent-pending technique of precision cleaning verification is for large components of cryogenic fluid systems. These are stainless steel, sand cast valve bodies with internal surface areas ranging from 0.2 to 0.9 m(exp 2). Extrapolation of this technique to components of even larger sizes (by orders of magnitude) is planned. Currently, the verification process is completely manual. In the new technique, a high velocity, low volume water stream impacts the part to be verified. This process is referred to as Breathing Air/Water Impingement and forms the basis for the Impingement Verification System (IVS). The system is unique in that a gas stream is used to accelerate the water droplets to high speeds. Water is injected into the gas stream in a small, continuous amount. The air/water mixture is then passed through a converging-diverging nozzle where the gas is accelerated to supersonic velocities. These droplets impart sufficient energy to the precision cleaned surface to place non-volatile residue (NVR) contaminants into suspension in the water. The sample water is collected and its NVR level is determined by total organic carbon (TOC) analysis at 880 C. The TOC, in ppm carbon, is used to establish the NVR level. A correlation between the present gravimetric CFC-113 NVR and the IVS NVR is found from experimental sensitivity factors measured for various contaminants. The sensitivity has the units of ppm of carbon per mg-ft(exp 2) of contaminant. In this paper, the equipment is described and data are presented showing the development of the sensitivity factors from a test set including four NVR's impinged from witness plates of 0.05 to 0.75 m(exp 2).

  18. Proceedings of the 21st DOE/NRC nuclear air cleaning conference

    International Nuclear Information System (INIS)

    The 21st meeting of the Department of Energy/Nuclear Regulatory Commission (DOE/NRC) Nuclear Air Cleaning Conference was held in San Diego, CA on August 13--16, 1990. The proceedings have been published as a two volume set. Volume 2 contains sessions covering adsorbents, nuclear codes and standards, modelling, filters, safety, containment venting and a review of nuclear air cleaning programs around the world. Also included is the list of attendees and an index of authors and speakers

  19. Political Factors Affecting the Enactment of State-Level Clean Indoor Air Laws

    Science.gov (United States)

    Vernick, Jon S.; Stuart, Elizabeth A.; Webster, Daniel W.

    2014-01-01

    Objectives. We examined the effects of key political institutional factors on the advancement of state-level clean indoor air laws. Methods. We performed an observational study of state-level clean indoor air law enactment among all 50 US states from 1993 to 2010 by using extended Cox hazard models to assess risk of enacting a relevant law. Results. During the 18-year period from 1993 to 2010, 28 states passed a law covering workplaces, 33 states passed a law covering restaurants, 29 states passed a law covering bars, and 16 states passed a law covering gaming facilities. States with term limits had a 2.15 times greater hazard (95% confidence interval [CI] = 1.27, 3.65; P = .005) of enacting clean indoor air laws. The presence of state-level preemption of local clean indoor air laws was associated with a 3.26 times greater hazard (95% CI = 1.11, 9.53; P = .031) of state-level policy enactment. In the presence of preemption, increased legislative professionalism was strongly associated (hazard ratio = 3.28; 95% CI = 1.10, 9.75; P = .033) with clean indoor air law enactment. Conclusions. Political institutional factors do influence state-level clean indoor air law enactment and may be relevant to other public health policy areas. PMID:24825239

  20. Evaluating The Operation Of Three Air Cleaners Working Individually In A Clean Room

    OpenAIRE

    Ardkapan, Siamak Rahimi; Afshari, Alireza; Bergsøe, Niels Christian; Johnson, Matthew S.

    2011-01-01

    The use of portable air cleaners is becoming increasingly popular in many countries includingDenmark. Portable air cleaners are known for not only removing but also generating particles andgases. To clarify this, three air cleaning technologies were evaluated. They were nonthermalplasma, photochemical air purifier and corona discharge ionizer. The concentrations of ultrafineparticles, ozone and total volatile organic compounds were measured both in a duct and in a cleanroom. It was found that...

  1. Investigation of efficiency of air cleaning from acetone using a segmental construction biofilter

    OpenAIRE

    Denas Bacevičius; Alvydas Zagorskis

    2015-01-01

    Volatile organic compounds, e. g. acetone, have a direct impact on climate change, decrease of ozone in the air, and on the growth of greenhouse effect. One of the most popular air purifying methods from VOC is a biological air cleaning. Experimental investigations were conducted to determine the efficiency of the new structure of biofilter with polypropylene plates segments. During the investigations the efficiency of segmental construction biofilter of air purification at different initial ...

  2. Proceedings of the 19th DOE/NRC nuclear air cleaning conference

    International Nuclear Information System (INIS)

    This document contains the papers and the associated discussions of the 19 DOE/NRC Nuclear Air Cleaning Conference. Sessions were devoted to (1) fire, explosion and accident analysis, (2) adsorption and iodine retention, (3) filters and filter testing, (4) standards and regulation, (5) treatment of radon, krypton, tritium and carbon-14, (6) ventilation and air cleaning in reactor operations, (7) dissolver off-gas cleaning, (8) adsorber fires, (9) nuclear grade carbon testing, (10) sampling and monitoring, and (11) field test experience. Individual papers were processed separately for the data base

  3. Cleaning and air conditioning device for atmosphere in thermonuclear reactor chamber

    International Nuclear Information System (INIS)

    The device of the present invention removes tritium efficiently and attains ventilation and conditioning of a great amount of air flow. That is, there are disposed a humidity separator, a filter, a heater, a catalyst filled layer, a water jetting type humidifying heat insulation cooler and a cooler in this order from an inlet side (upstream) of contaminated room atmospheric gases. The catalyst filled layer, etc. are incorporated integrally into the ventilation air conditioning facility for ventilating air in the chamber of the thermonuclear reactor, to clean a tritium atmosphere at the same time. Accordingly, the device is made compact as a whole. A limit for the air flow rate owing to the use of the conventional catalyst tower and adsorbing tower is eliminated. Then a ventilating air conditioning for a great flow rate can be attained. Tritium is removed by cooling and dehumidification without using any adsorbent. Accordingly, an adsorbing tower is no more necessary and conventional regeneration operation is not required. As a result, space for installation is reduced, the system is simplified and the cost for construction and facility can be reduced. (I.S.)

  4. Air cleaning efficiency of deodorant materials under dynamic conditions: effect of air flow rate

    DEFF Research Database (Denmark)

    Mizutani, Chiyomi; Bivolarova, Mariya Petrova; Melikov, Arsen Krikor;

    2014-01-01

    evaluated as deodorant materials neutralising ammonia in air. The deodorant material efficiency was tested in a special experimental set-up consisting of a straight pipe section, an ammonia gas generator, a fan and a textile frame. The deodorant materials, placed in the pipe, were exposed to a flow of air......Unpleasant odor is a serious problem in hospitals and elderly facilities. One of the unpleasant odors is ammonia originating from human urine and sweat. The air cleaning efficiency of porous activated carbon fiber fabric which has been treated with acid, and porous activated carbon fiber fabric was...... mixed with ammonia gas at a concentration of 20 ppm and velocities of 0.05, 0.15, 0.3 and 1.2 m/s. The activated carbon fibers treated with acid had a high deodorizing effect for ammonia (0.8) at a velocity of 0.05 m/s. The deodorizing effect of this material decreased with the increase in the velocity...

  5. Self-scrubbing coal{sup TM}: An integrated approach to clean air. A proposed Clean Coal Technology Demonstration Project

    Energy Technology Data Exchange (ETDEWEB)

    1994-01-01

    This environmental assessment (EA) was prepared by the U.S.Department of Energy (DOE), with compliance with the National Environmental Policy Act (NEPA) of 1969, Council on Environmental Quality (CE) regulations for implementating NEPA (40 CFR 1500-1508) and DOE regulations for compliance with NEPA (10 CFR 1021), to evaluate the potential environmental impacts associated with a proposed demonstration project to be cost-shared by DOE and Custom Coals International (CCI) under the Clean Coal Technology (CCT) Demonstration Program of DOE`s Office of Fossil Energy. CCI is a Pennsylvania general partnership located in Pittsburgh, PA engaged in the commercialization of advanced coal cleaning technologies. The proposed federal action is for DOE to provide, through a cooperative agreement with CCI, cost-shared funding support for the land acquisition, design, construction and demonstration of an advanced coal cleaning technology project, {open_quotes}Self-Scrubbing Coal: An Integrated Approach to Clean Air.{close_quotes} The proposed demonstration project would take place on the site of the presently inactive Laurel Coal Preparation Plant in Shade Township, Somerset County, PA. A newly constructed, advanced design, coal preparation plant would replace the existing facility. The cleaned coal produced from this new facility would be fired in full-scale test burns at coal-fired electric utilities in Indiana, Ohio and PA as part of this project.

  6. Efficiency enhancement in IGCC power plants with air-blown gasification and hot gas clean-up

    International Nuclear Information System (INIS)

    Air-blown IGCC systems with hot fuel gas clean-up are investigated. In detail, the gas clean-up station consists of two reactors: in the first, the raw syngas exiting the gasifier and passed through high-temperature syngas coolers is desulfurized by means of a zinc oxide-based sorbent, whereas in the second the sulfided sorbent is duly regenerated. The hot fuel gas clean-up station releases H2S-free syngas, which is ready to fuel the combustion turbine after hot gas filtration, and a SO2-laden stream, which is successively treated in a wet scrubber. A thermodynamic analysis of two air-blown IGCC systems, the first with cold fuel gas clean-up and the second with hot fuel gas clean-up, both with a state-of-the-art combustion turbine as topping cycle, shows that it is possible to obtain a really attractive net efficiency (more than 51%) for the second system, with significant improvements in comparison with the first system. Nevertheless, higher efficiency is accomplished with a small reduction in the power output and no sensible efficiency improvements seem to be appreciated when the desulfurization temperature increases. Other IGCC systems, with an advanced 1500 °C-class combustion turbine as the result of technology improvements, are investigated as well, with efficiency as high as 53%. - Highlights: ► Hot fuel gas clean-up is a highly favorable technology for IGCC concepts. ► Significant IGCC efficiency improvements are possible with hot fuel gas clean-up. ► Size reductions of several IGCC components are possible. ► Higher desulfurization temperatures do not sensibly affect IGCC efficiency. ► IGCC efficiency as high as 53% is possible with a 1500°C-class combustion turbine

  7. Implications of the Clean Air Act acid rain title on industrial boilers

    International Nuclear Information System (INIS)

    This paper discusses the impacts of the 1990 Clean Air Act Amendments related to acid rain controls, as they apply to industrial boilers. Emphasis is placed on explaining the Title IV provisions of the Amendments that permit nonutility sources to participate in the SO2 allowance system. The allowance system, as it pertains to industrial boiler operators, is described, and the opportunities for operators to trade and/or sell SO2 emission credits is discussed. The paper also reviews flue gas desulfurization system technologies available for industrial boiler operators who may choose to participate in the system. Furnace sorbent injection, advanced silicate process, lime spray drying, dry sorbent injection, and limestone scrubbing are described, including statements of their SO2 removing capability, commercial status, and costs. Capital costs, levelized costs and cost-effectiveness are presented for these technologies

  8. Self-Scrubbing Coal -- an integrated approach to clean air

    Energy Technology Data Exchange (ETDEWEB)

    Harrison, K.E. [Custom Coals Corp., Pittsburgh, PA (United States)

    1997-12-31

    Carefree Coal is coal cleaned in a proprietary dense-media cyclone circuit, using ultrafine magnetite slurries, to remove noncombustible material, including up to 90% of the pyritic sulfur. Deep cleaning alone, however, cannot produce a compliance fuel from coals with high organic sulfur contents. In these cases, Self-Scrubbing Coal will be produced. Self-Scrubbing Coal is produced in the same manner as Carefree Coal except that the finest fraction of product from the cleaning circuit is mixed with limestone-based additives and briquetted. The reduced ash content of the deeply-cleaned coal will permit the addition of relatively large amounts of sorbent without exceeding boiler ash specifications or overloading electrostatic precipitators. This additive reacts with sulfur dioxide (SO{sub 2}) during combustion of the coal to remove most of the remaining sulfur. Overall, sulfur reductions in the range of 80--90% are achieved. After nearly 5 years of research and development of a proprietary coal cleaning technology coupled with pilot-scale validation studies of this technology and pilot-scale combustion testing of Self-Scrubbing Coal, Custom Coals Corporation organized a team of experts to prepare a proposal in response to DOE`s Round IV Program Opportunity Notice for its Clean Coal Technology Program under Public Law 101-121 and Public Law 101-512. The main objective of the demonstration project is the production of a coal fuel that will result in up to 90% reduction in sulfur emissions from coal-fired boilers at a cost competitive advantage over other technologies designed to accomplish the same sulfur emissions and over naturally occurring low sulfur coals.

  9. Human Response to Ductless Personalized Ventilation with Local Air Cleaning: Air Quality and Prevalence of SBS Symptoms

    OpenAIRE

    Dalewski, Mariusz; Bivolarova, Maria; Fillon, Maelys; Melikov, Arsen Krikor

    2013-01-01

    The impact of local air cleaning and cooling of the head region by ductless personalized ventilation (DPV) on perceived air quality (PAQ) and Sick Building Syndrome (SBS) symptoms was studied. Thirty subjects participated in experiments performed in a test room with displacement ventilation (DV) and six workstations, three of which had DPV. The DV kept air temperature in the occupied zone (1.1 m above the floor). Pollution load was simulated by PVC floor covering and the bioeffluents generate...

  10. 40 CFR 60.2971 - What are the emission limitations for air curtain incinerators that burn only wood waste, clean...

    Science.gov (United States)

    2010-07-01

    ... air curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.2971 Section 60... Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.2971 What are the emission limitations for air curtain incinerators that burn only wood waste, clean lumber, and yard waste? (a)...

  11. 40 CFR 60.3066 - What are the emission limitations for air curtain incinerators that burn only wood waste, clean...

    Science.gov (United States)

    2010-07-01

    ... air curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.3066 Section 60... Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3066 What are the emission limitations for air curtain incinerators that burn only wood waste, clean lumber, and yard...

  12. Plasma coating formed TIO2 catalysts usage in cleaning the air from nitrogen oxides and carbon monoxide

    OpenAIRE

    Vitalij Kolodynskij; Pranas Baltrėnas

    2015-01-01

    The present catalytic air purification device–air cleaning device is capable to reduce nitrogen oxide sand carbon monoxide concentrations in polluted air stream and to achieve high cleaning efficiency. The principle of operation of catalytic air cleaning device is based on plasma coating formed catalysts usage. At high temperatures and oxygen concentrations in the experimental device channel, catalysts become active and reactions of conversion of pollutants start. In this research, the effici...

  13. Apparatuses, Systems and Methods for Cleaning Photovoltaic Devices

    KAUST Repository

    Eitelhuber, Georg

    2013-02-14

    Embodiments of solar panel cleaning apparatuses, solar panel cleaning systems, and solar panel cleaning methods are disclosed. In certain embodiments, the disclosed solar panel cleaning apparatuses, systems and methods do may not require any water or other cleaning liquids in the whole cleaning process, which makes them prominent well suited in for water-deficit environments such as deserts. In one embodiment, the solar panel cleaning apparatus comprises one or more rotatable brushes each having a rotational axis and a drive configured to move each of the one or more rotatable brushes in a direction that is not perpendicular to the rotational axis. The solar panel cleaning apparatus is may be configured such that the angle of the rotational axis of at least one of the one or more rotatable brushes is adjustable relative to the direction of travel.

  14. Human Response to Ductless Personalised Ventilation: Impact of Air Movement, Temperature and Cleanness on Eye Symptoms

    DEFF Research Database (Denmark)

    Dalewski, Mariusz; Fillon, Maelys; Bivolarova, Maria;

    2013-01-01

    environment facially applied individually controlled air movement of room air, with or without local filtering, did not have significant impact on eye blink frequency and tear film quality. The local air movement and air cleaning resulted in increased eye blinking frequency and improvement of tear film......The performance of ductless personalized ventilation (DPV) in conjunction with displacement ventilation (DV) was studied in relation to peoples’ health, comfort and performance. This paper presents results on the impact of room air temperature, using of DPV and local air filtration on eye blink...

  15. Enlisting municipal governments in a national approach to clean air and climate change

    International Nuclear Information System (INIS)

    The Federation of Canadian Municipalities (FCM) and the Government of Canada have a shared commitment to improve environmental performance and protect the health of Canadians. Air pollution and climate change are also a shared responsibility among federal, municipal and provincial/territorial governments. Although they operate independently, their policies and programs tend to overlap. This is both costly and inefficient. In order to create synergies and leverage the role and potential of each level of government, the FCM proposed a national approach to clean air and climate change. The approach involves all levels of government in a nationally coordinated effort, with roles appropriate to their capacities. The municipal role in clean air and climate change action, roles and responsibilities of municipal governments, and guiding principles of a new Canadian approach were discussed in this document. Recommendations and next steps were also identified. They centred on the following themes: enhancing public transit, clean transportation and related infrastructure; improving commercial and residential building efficiency; stimulating ongoing productivity and pollution prevention within municipal operations through incentives and policies; enhancing clean energy; strengthened and enforceable air quality standards; emissions trading; climate change adaptation; public education and awareness; and demonstrating success and ensuring accountability. The document concluded that only a long-term intergovernmental partnership can meet the challenges posed by climate change and air pollution. FCM urged the Government of Canada to adopt an integrative and strategic approach to clean air and climate change by enlisting municipal governments as partners in both its development and implementation

  16. 78 FR 51186 - Proposed Consent Decree, Clean Air Act Citizen Suit

    Science.gov (United States)

    2013-08-20

    ... AGENCY Proposed Consent Decree, Clean Air Act Citizen Suit AGENCY: Environmental Protection Agency (EPA). ACTION: Notice of Proposed Consent Decree; Request for Public Comment. SUMMARY: In accordance with... decree, to resolve a deadline suit filed by Air Alliance Houston, California Communities Against...

  17. VENTILATED AIR AERODYNAMICS IN DEVICE FOR CLEANING FROM FINE-DISPERSED MOISTURE

    Directory of Open Access Journals (Sweden)

    V. N. Kobelev,

    2010-10-01

    Full Text Available Problem statement. The efficiency of ventilation air cleaning is defined by the time dependence of concentration of fine-dispersed moisture in environmental chamber for testing electronic products.Results and conclusions. An aerodynamic calculation technique of the element of ventilated air cleaning assembly is proposed with consideration for specific fea-tures of determination of the concentration of fine-dispersed drop-like and solid particles arriving with atmospheric air drawn by ventilator. The calculation of constructional parameters of automatic condensate extractor is described having regard to removed mass of pollutants. This mass changes depending on environ-mental conditions and technology of manufacturing of finished products.

  18. How can the Clean Development Mechanism contribute to better air quality?

    Energy Technology Data Exchange (ETDEWEB)

    Bakker, S.J.A. [ECN Policy Studies, Petten (Netherlands)

    2009-06-15

    Air pollutants and greenhouse gases are to a large extent emitted by the same sources, notably in the industry, transport and residential sectors. However, climate change mitigation is a global issue and is mostly driven by national and international policy. Local governments are in general more interested in improving urban air quality, which is posing serious health hazards across the globe. The Clean Development Mechanism (CDM) was designed to reduce greenhouse gas emissions, helping industrialised countries to achieve their targets under the Kyoto Protocol while contributing to sustainable development in developing countries. As of January 2009 over 4000 projects are in the pipeline. The CDM could be used by local governments and the private sector to finance projects that contribute to both climate change mitigation and better air quality. However, CDM projects in particularly the transport sector face a number of barriers. We identify the most important issues for such projects, as well as the lessons learnt and some recommendations based on four case studies in Asian cities related to biofuels and bus rapid transit systems. The main conclusions is that successful implementation of CDM projects beneficial for urban air quality depends on the applicability of approved CDM methodologies, the strong cooperation between project developers and local authorities, and the availability of data.

  19. Socio-economic considerations of cleaning Greater Vancouver's air

    International Nuclear Information System (INIS)

    Socio-economic considerations of better air quality on the Greater Vancouver population and economy were discussed. The purpose of the study was to provide socio-economic information to staff and stakeholders of the Greater Vancouver Regional District (GVRD) who are participating in an Air Quality Management Plan (AQMP) development process and the Sustainable Region Initiative (SRI) process. The study incorporated the following methodologies: identification and review of Canadian, American, and European quantitative socio-economic, cost-benefit, cost effectiveness, competitiveness and health analyses of changes in air quality and measures to improve air quality; interviews with industry representatives in Greater Vancouver on competitiveness impacts of air quality changes and ways to improve air quality; and a qualitative analysis and discussion of secondary quantitative information that identifies and evaluates socio-economic impacts arising from changes in Greater Vancouver air quality. The study concluded that for the Greater Vancouver area, the qualitative analysis of an improvement in Greater Vancouver air quality shows positive socio-economic outcomes, as high positive economic efficiency impacts are expected along with good social quality of life impacts. 149 refs., 30 tabs., 6 appendices

  20. The Political Economy of Clean Air Legislation. An Analysis of Voting in the U.S. Senate on Amendments to the 1990 Clean Air Act

    International Nuclear Information System (INIS)

    Much research in political science and economics has attempted to explain voting patterns among members of legislative bodies. In this paper we extend the existing analysis in three ways. First, we address the subject of voting on air quality regulation by the U.S. Senate. A subject of great importance and significance, such votes have not previously been the focus of much empirical investigation. Second, we develop an arguably more correct and effective methodology for measuring and understanding the ideological preferences of individual Senators, as revealed by their voting patterns on 1990 amendments to the Clean Air Act. Third, we apply the minimum chi-square methodology for estimating the determinants of Senator voting patterns on the issue. In Section 2, the economic theory of regulation is elaborated as it is specifically related to 1990 senate voting on amendments to the Clean Air Act. In Section 3, we provide a brief literature review, focusing on the principal-agent model and how voting patterns are influenced by campaign contributions, constituent socio-economic characteristics, and individual legislator ideology. In Section 4 we present a very simple model of the principal-agent relationship which underlies legislative voting behavior. In this section (supplemented by information in an appendix) we introduce a new methodology for creating a proxy variable to represent legislator ideology, comparing the new method with those previously used. Section 5 provides a chronological background on clean air legislation, and Section 6 discusses the data and proxy variables used for the empirical estimations. Section 7 contains a presentation and evaluation of three empirical techniques, including one not previously used, the minimum chi-square method which, we argue, is both appropriate and easily interpretable. This claim is based upon the fact that the dependent variable, SCORE, is neither continuous nor dichotomous, but ordered and categorical, constructed

  1. Ventilation and air cleaning plant experience in fast reactor fuel cycle facilities at Dounreay

    International Nuclear Information System (INIS)

    This paper is about work to measure the quantity and quality of aerosols created in Fast Reactor Fuel Cycle Facilities. Such facilities typically contain large amounts of Pu, Actinides, Fission Products often in a dispersable form, which pose varied challenges to ventilation systems in general and clean up devices in particular. Fluidic (no moving part) devices have been used intensively for the past 5 years at Dounreay and their performance will be discussed. Of particular importance has been their use on small enclosures such as gloveboxes, where they have made an important contribution in minimising activity escape. A large amount of data on HEPA filter performance in various parts of the facility has now been accumulated. Testing experience, particularly in situ of HEPAs will be presented and the problems encountered discussed. Factors affecting HEPA life will be discussed. In the past the development of new filter housing and changing systems have been presented to the US ERDA Air Cleaning Conference. The performance of these devices under active conditions will be reported. Considerable work has been done on the estimation of residual alpha activity on used HEPAs by neutron counting and equipment developed to allow alpha activity to be detected down to very low levels. This can also be done for high gamma active filters inside lead shielding. System failures are discussed together with performance of safety equipment. (author)

  2. 75 FR 64726 - Science Advisory Board Staff Office; Request for Nominations of Experts To Serve on the Clean Air...

    Science.gov (United States)

    2010-10-20

    ... AGENCY Science Advisory Board Staff Office; Request for Nominations of Experts To Serve on the Clean Air Scientific Advisory Committee (CASAC) Air Monitoring and Methods Subcommittee (AMMS) AGENCY: Environmental... requesting public nominations of experts to serve on the Clean Air Scientific Advisory Committee (CASAC)...

  3. Exposure of ventilation system cleaning workers to harmful microbiological agents

    Directory of Open Access Journals (Sweden)

    Małgorzata Gołofit-Szymczak

    2013-10-01

    Full Text Available Background: Regular inspection of the cleanliness of the ventilation systems, as well as their periodic cleaning and disinfection, if necessary, are the main factors of the proper maintenance of each system. Performing maintenance operations on the ventilation system, workers are exposed to risk associated with the exposure to harmful biological agents. The aim of this study was to assess the employees' exposure to bioaerosols during maintenance work on ventilation systems. Material and Methods: Bioaerosol measurements were carried out using a button sampler. The microbial particles were collected on gelatin filters. Settled-dust samples from the inner surface of the air ducts and filter-mat samples were selected for the microbiological analysis. In the collected air, dust and filter samples the concentration of bacteria and fungi were determined. Results: Bacteria and fungi concentrations ranged between 3.6×102-2.2×104 CFU/m3 and 4.7×102-4.5×103 CFU/m3 at workplaces where the operations connected with mechanical ventilation cleaning were performed and 2.2×104-1.2×105 CFU/m3 and 9.8×101-2.5×102 CFU/m3 at workplaces where filter exchange was performed, respectively. The qualitative analysis of microorganisms isolated from the air in all studied workplaces revealed that the most prevalent bacteria belonged to Bacillus genus. The average concentrations of bacteria and fungi in filter-mat samples were 3.3×103 CFU/cm2 and 1.4×104 CFU/cm2, respectively. In settled-dust samples, average concentrations were 591 CFU/100 cm2 and 52 CFU/100 cm2, for bacteria and fungi respectively. Conclusions: Workers cleaning ventilation systems are exposed to harmful biological agents classified into risk groups, 1 and 2, according to their level of the risk of infection. The research conducted in the workplace can be the basis of risk assessment related to exposure to harmful biological agents during maintenance work in ventilation. Med Pr 2013;64(5:613–623

  4. Extract and cleaning of contaminated air in commercial kitchens : Ultraviolet technology

    OpenAIRE

    Alexandrova, Alevtina

    2009-01-01

    The subject of the project was a research about cleaning of contaminated air in commercial kitchens. Kitchen hoods must be cleaned from heat, moisture, smoke, and vaporized grease all the time. Accumulations of grease on kitchen equipment can easily be the reason of fire. The thesis presents literature review of various sources like books, reports, and Internet articles. Most of the articles and tests were maid by research institutes or big manufacture companies connected with ventilation ...

  5. Clean heating surfaces - a condition for a fuel consumption decrease (air heaters)

    International Nuclear Information System (INIS)

    Unclean heating surface from the water and the flame side has an influence on the exit gas temperature after combustion. That can be noticed from the gas temperature increase, which is a basic indication of the heating surface condition. Unavoidable, the heating surface has to be clean to get a more economical work of the unit. In this paper the means of cleaning air heater heating surfaces from the flame side are given. (author). 2 tabs., 1 fig

  6. Should You Have the Air Ducts in Your Home Cleaned?

    Science.gov (United States)

    ... your indoor air. You have probably seen an advertisement, received a coupon in the mail, or been ... Hotline News Blog Apps Widgets Social sites: Twitter Facebook YouTube Flickr Instagram More social media at EPA »

  7. Can Market Forces Clean The Air In Metro Manila?

    OpenAIRE

    Catherine Frances J. Corpuz

    1999-01-01

    Metro Manila, like many cities in Southeast Asia, is badly affected by poor air quality. Legislation has failed to combat the problem due to inadequate regulatory enforcement and industry's cavalier attitude towards pollution. However a recent economic study has found that a solution to this crisis could be provided by taxation and other similar economic instruments. The study drew on a wide range of research and information to get an overview of the air pollution situation in Metro Manila. T...

  8. Device for cleaning regenerative air heaters of a boiler unit

    Energy Technology Data Exchange (ETDEWEB)

    Guzenko, S.I.; Buyevich, V.V.

    1982-01-01

    The device contains injection supersonic nozzles to which live steam of high pressure from the boiler SH is supplied through the reducer. An additional steam heater is connected to the plan arranged in the convective gas line of the boiler. In this case the heat exchanger of steam is heated to temperature excluding its condensation and precipitation of dew of sulfuric acid during injection of the RAH. The use of the proposed device improves the quality of cleaning and makes it possible to abandon stopping of the RAH for stopover water flushing.

  9. 圆形断面净化空调机组相关问题的探讨%Discussion on air handling unit with circular section for cleaning air system

    Institute of Scientific and Technical Information of China (English)

    初春玲; 周俊彦

    2013-01-01

    Establishes the mathematical model and compares the frictional resistance, the sectional air speed and resistance of surface air coolers and filters, and sound insulation performance, between circular section and square section AHUs. The results show that the frictional resistance of a circular section AHU is 11% lower than that of a square section AHU at the costs of increased space requirement for the plant room, obviously increased resistance of the surface air coolers and filters and poorer sound insulation effects.%建立了数学模型,对比分析了圆形断面和正方形断面空调机组的沿程阻力,表冷器、过滤器的断面风速和阻力,机组的隔声性能.结果表明,在相同条件下,圆形断面空调机组的沿程阻力可以降低11%,但是以多占用机房面积为代价的;表冷器、过滤器阻力明显增加;机组壁板的隔声效果较差.

  10. Nanomaterials for benign indoor environments: Electrochromics for 'smart windows', sensors for air quality, and photo-catalysts for air cleaning

    International Nuclear Information System (INIS)

    Nanomaterials can be used in a number of technologies in order to accomplish benign indoor environments. This paper takes a unified view on this problem from a solar-energy-based perspective and specifically considers electrochromics for achieving good day-lighting jointly with energy efficiency, sensors aimed at air quality assessment, and photocatalysis for air cleaning. Recent results, mainly from the authors' laboratories, are reported for all of these areas. (author)

  11. Air System Information Management

    Science.gov (United States)

    Filman, Robert E.

    2004-01-01

    I flew to Washington last week, a trip rich in distributed information management. Buying tickets, at the gate, in flight, landing and at the baggage claim, myriad messages about my reservation, the weather, our flight plans, gates, bags and so forth flew among a variety of travel agency, airline and Federal Aviation Administration (FAA) computers and personnel. By and large, each kind of information ran on a particular application, often specialized to own data formats and communications network. I went to Washington to attend an FAA meeting on System-Wide Information Management (SWIM) for the National Airspace System (NAS) (http://www.nasarchitecture.faa.gov/Tutorials/NAS101.cfm). NAS (and its information infrastructure, SWIM) is an attempt to bring greater regularity, efficiency and uniformity to the collection of stovepipe applications now used to manage air traffic. Current systems hold information about flight plans, flight trajectories, weather, air turbulence, current and forecast weather, radar summaries, hazardous condition warnings, airport and airspace capacity constraints, temporary flight restrictions, and so forth. Information moving among these stovepipe systems is usually mediated by people (for example, air traffic controllers) or single-purpose applications. People, whose intelligence is critical for difficult tasks and unusual circumstances, are not as efficient as computers for tasks that can be automated. Better information sharing can lead to higher system capacity, more efficient utilization and safer operations. Better information sharing through greater automation is possible though not necessarily easy.

  12. Precision Clean Hardware: Maintenance of Fluid Systems Cleanliness

    Science.gov (United States)

    Sharp, Sheila; Pedley, Mike; Bond, Tim; Quaglino, Joseph; Lorenz, Mary Jo; Bentz, Michael; Banta, Richard; Tolliver, Nancy; Golden, John; Levesque, Ray

    2003-01-01

    The ISS fluid systems are so complex that fluid system cleanliness cannot be verified at the assembly level. A "build clean / maintain clean" approach was used by all major fluid systems: Verify cleanliness at the detail and subassembly level. Maintain cleanliness during assembly.

  13. Preliminary assessment of future refining impacts of the Clean Air Act Amendments of 1990

    International Nuclear Information System (INIS)

    A preliminary assessment of the future refining impacts of the Clean Air Act Amendments of 1990 has been performed with the Navy Mobility Fuels Forecasting Systems. The assessment suggests that gasoline reformulation costs in domestic coastal and near-coastal refining regions in the year 2000 could be 3.5 to 5.6 cents per gallon (in terms of 1989 currency). For heating value equivalent to one gallon of conventional gasoline, the regional total added costs (including reformulation costs) for reformulated gasoline could be 5.9 to 8.0 cents. In blending reformulated gasolines, the reduction of butane for lower Reid vapor pressure and the reduction of reformate for lower aromatics are generally compensated by increased percentages of alkylate and/or straight run naphthas. Relatively larger refinery process capacity additions are required for butane isomerization, alkylation, aromatics recovery, and distillate hydrotreating. 21 refs., 3 figs., 18 tabs

  14. A centrifuge CO2 pellet cleaning system

    Science.gov (United States)

    Foster, C. A.; Fisher, P. W.; Nelson, W. D.; Schechter, D. E.

    1995-01-01

    An advanced turbine/CO2 pellet accelerator is being evaluated as a depaint technology at Oak Ridge National Laboratory (ORNL). The program, sponsored by Warner Robins Air Logistics Center (ALC), Robins Air Force Base, Georgia, has developed a robot-compatible apparatus that efficiently accelerates pellets of dry ice with a high-speed rotating wheel. In comparison to the more conventional compressed air 'sandblast' pellet accelerators, the turbine system can achieve higher pellet speeds, has precise speed control, and is more than ten times as efficient. A preliminary study of the apparatus as a depaint technology has been undertaken. Depaint rates of military epoxy/urethane paint systems on 2024 and 7075 aluminum panels as a function of pellet speed and throughput have been measured. In addition, methods of enhancing the strip rate by combining infra-red heat lamps with pellet blasting and by combining the use of environmentally benign solvents with the pellet blasting have also been studied. The design and operation of the apparatus will be discussed along with data obtained from the depaint studies.

  15. Airborne lidar mapping of vertical ozone distributions in support of the 1990 Clean Air Act Amendments

    International Nuclear Information System (INIS)

    The 1990 Clean Air Act Amendments mandated attainment of the ozone standard established by the U.S. Environmental Protection Agency. Improved photochemical models validated by experimental data are needed to develop strategies for reducing near surface ozone concentrations downwind of urban and industrial centers. For more than 10 years, lidar has been used on large aircraft to provide unique information on ozone distributions in the atmosphere. However, compact airborne lidar systems are needed for operation on small aircraft of the type typically used on regional air quality investigations to collect data with which to develop and validate air quality models. Data presented in this paper will consist of a comparison between airborne differential absorption lidar (DIAL) and airborne in-situ ozone measurements. Also discussed are future plans to improve the airborne ultraviolet-DIAL for ozone and other gas observations and addition of a Fourier Transform Infrared (FTIR) emission spectrometer to investigate the effects of other gas species on vertical ozone distribution

  16. Evidence of recovery of Juniperus virginiana trees from sulfur pollution after the Clean Air Act

    OpenAIRE

    Thomas, Richard B.; Spal, Scott E.; Smith, Kenneth R.; Nippert, Jesse B.

    2013-01-01

    This study shows that red cedar trees growing in the Central Appalachian Mountains of West Virginia are recovering from decades of acidic pollution. Our study shows the efficacy of the Clean Air Act in a region where acidic pollution levels were some of the highest in the United States before the Clean Air Act. We demonstrate that a large portion of the increase in water use efficiency of trees that is often attributed to increasing atmospheric CO2 over the last century may be caused by acid ...

  17. RAPID MAPPING FOR CLEAN AIR IN COMMERCE CITY

    Science.gov (United States)

    The goal of this project is to demonstrate innovative methods for providing timely reporting of the spatial and temporal distribution of air pollutants in a heavily industrialized urban community. This methodology will utilize data from real-time measurements of meteorological...

  18. Proceedings of the 10th world clean air congress. Emissions and control

    International Nuclear Information System (INIS)

    Rapid economical growth and expansion of human population have produced a number of environmental problems with varying geographic dimensions. While local problems remain near the pollution sources, the focus of the scientific community is more and more shifted towards regional, continental and global consequences of air pollutants. The theme of the 10th Clean Air Congress 'Growing Challenges from Local to Global' reflects the growing demand from the scientific and professional community working in air pollution prevention and environmental protection - more and more complex mechanisms should be understood on a growing spatial scale. The 10th World Clean Air Congress addresses in its more than 400 presentations, documented in three Volumes of Proceedings, the history, the present and the potential futures of the air pollution problems. Air has during different times always represented something valuable to people: the logo of the Congress, the octahedron sign, sympolizes the element of air in acient Greek philosophy. Today air quality is not only valued as important, it is a death serious matter. This Volume includes the presentations of the path A 'Emissions and Control' of the Congress. This path deals with issues related to measurement, monitoring and inventories of air pollutants from mobile and stationary sources, and the various ways to control the emissions of acidifying pollutants, air toxics and aerosols, volatile organic compounds, and odours. Integrated approaches to pollution prevention and non-waste technologies in various industrial sectors, have recently obtained special attention

  19. Human Response to Ductless Personalized Ventilation with Local Air Cleaning: Air Quality and Prevalence of SBS Symptoms

    DEFF Research Database (Denmark)

    Dalewski, Mariusz; Bivolarova, Maria; Fillon, Maelys;

    2013-01-01

    The impact of local air cleaning and cooling of the head region by ductless personalized ventilation (DPV) on perceived air quality (PAQ) and Sick Building Syndrome (SBS) symptoms was studied. Thirty subjects participated in experiments performed in a test room with displacement ventilation (DV......) and six workstations, three of which had DPV. The DV kept air temperature in the occupied zone (1.1 m above the floor). Pollution load was simulated by PVC floor covering and the bioeffluents generated by the subjects (60% recirculated room air). DPV sucked the air distributed over the floor by the DV...... and supplied it to the breathing zone of the subjects. The subjects were allowed to control the position of the DPV supply diffuser and the personalized flow rate. Each subject participated in five 4-hour experiments: 23 °C with DV only, 23 °C with DPV with air filter, 29 °C with DV only, 29 °C with...

  20. No Need to Wait for the Clean Air Dividend

    Science.gov (United States)

    Shindell, Drew

    2012-01-01

    precursor is methane, which is also a powerful greenhouse gas in its own right. Control measures include reducing leaks from natural gas pipelines and storage tanks, and capturing it from coal, gas and oil extraction, landfills and wastewater treatment plants. Aeration of rice paddies and manure management can also reduce methane releases. Captured methane can often be sold or turned into power. In Monterrey, Mexico, for example, electricity generated from methane collected from the city landfill powers the public transportation system. So such measures can be beneficial even when ignoring the health and climate effects, as they can contribute to energy security and often pay for themselves. According to calculations by me and my colleagues, phasing in all these measures over the next 20 years would reduce global warming by about 0.5 degC in 2050, half of the projected increase between now and then (Science, vol 335, p 183). Regional benefits would be even greater, as black carbon disrupts rainfall patterns and magnifies warming and melting of snow and ice in parts of the world including the Arctic and the Himalayas. On top of the climate benefits, cutting black carbon and ozone would prevent over 3 million premature deaths from air pollution, and increase yields of staple crops by roughly 50 million tonnes a year. Improved cooking stoves would also decrease the demand for firewood in the developing world, reducing deforestation and freeing up time for those who collect wood - primarily women and children - to pursue other activities such as education. Similarly, improved brick kilns now being used in parts of Latin America and Asia require half as much fuel as traditional ones and are less time-intensive for the operators. This means that in addition to their environmental benefits, these measures can contribute to sustainable and human development. Tackling black carbon and methane is clearly a great idea, so why hasn't it been done already? There are many barriers. The

  1. The California fuel cell partnership: an avenue to clean air

    Science.gov (United States)

    Lloyd, Alan C.

    The California Fuel Cell Partnership presently consists of eight private companies, two state agencies and a federal government representative that will attempt to demonstrate the feasibility of fuel cell cars and buses. California has attempted to advance the commercialization of zero-emission vehicles for much of the past decade to help the state reduce its high levels of air pollution. A special advisory panel convened by the California Air Resources Board concluded last year that fuel cell technology could meet the key requirements for automobiles. The successful commercialization of fuel cell vehicles would help to reduce the levels of ozone, fine particles and toxic air contaminants that pose health risks to California's population. This technology can also help to reduce carbon dioxide emissions. California regulations now encourage the development of zero and near-zero emission vehicle technologies, including fuel cells. The Fuel Cell Partnership will operate approximately 50 fuel cell cars and buses until the year 2003 in order to produce important information on the vehicles and fueling infrastructure needed to support them.

  2. Extended-life nuclear air cleaning filters via dynamic exclusion prefilters

    Energy Technology Data Exchange (ETDEWEB)

    Wright, S.R.; Crouch, H.S.; Bond, J.H. [Micro Composite Materials Corp., Durham, NC (United States)

    1997-08-01

    The primary objective of this investigation was to ascertain if a dynamic, self-cleaning particulate exclusion precleaner, designed for relatively large dust removal (2 to 100+ {mu}m diameter particles) from helicopter turbine inlets, could be extended to submicron filtration. The improved device could be used as a prefilter for HEPA filtration systems, significantly increasing service life. In nuclear air cleaning, its use would reduce the amount of nuclear particulate matter that would otherwise be entrapped in the HEPA filter cartridge/panel, causing fouling and increased back pressure, as well as requiring subsequent disposal of the contaminated media at considerable expense. A unique (patent-pending) mechanical separation device has recently been developed to extract particulate matter from fluid process streams based on a proprietary concept called Boundary Layer Momentum Transfer (BLMT). The device creates multiple boundary layers that actively exclude particles from entering the perimeter of the device, while allowing air to traverse the boundaries relatively unimpeded. A modified two-dimensional (2-D) computerized flow simulation model was used to assist in the prototype design. Empirical results are presented from particle breakthrough and AP experiments obtained from a reduced-scale prototype filter. Particles larger than 0.23 {mu}m were actively excluded by the prototype, but at a higher pressure drop than anticipated. Experimental data collected indicates that the filter housing and the inlet flow configuration may contribute significantly to improvements in device particle separation capabilities. Furthermore, preliminary experiments have shown that other downstream pressure drop considerations (besides those just across the spinning filtration disks) must be included to accurately portray the AP across the device. Further detailed quantitative investigations on a larger scale (1,000 CFM) prototype are warranted. 3 refs., 5 figs., 2 tabs.

  3. Extended-life nuclear air cleaning filters via dynamic exclusion prefilters

    International Nuclear Information System (INIS)

    The primary objective of this investigation was to ascertain if a dynamic, self-cleaning particulate exclusion precleaner, designed for relatively large dust removal (2 to 100+ μm diameter particles) from helicopter turbine inlets, could be extended to submicron filtration. The improved device could be used as a prefilter for HEPA filtration systems, significantly increasing service life. In nuclear air cleaning, its use would reduce the amount of nuclear particulate matter that would otherwise be entrapped in the HEPA filter cartridge/panel, causing fouling and increased back pressure, as well as requiring subsequent disposal of the contaminated media at considerable expense. A unique (patent-pending) mechanical separation device has recently been developed to extract particulate matter from fluid process streams based on a proprietary concept called Boundary Layer Momentum Transfer (BLMT). The device creates multiple boundary layers that actively exclude particles from entering the perimeter of the device, while allowing air to traverse the boundaries relatively unimpeded. A modified two-dimensional (2-D) computerized flow simulation model was used to assist in the prototype design. Empirical results are presented from particle breakthrough and AP experiments obtained from a reduced-scale prototype filter. Particles larger than 0.23 μm were actively excluded by the prototype, but at a higher pressure drop than anticipated. Experimental data collected indicates that the filter housing and the inlet flow configuration may contribute significantly to improvements in device particle separation capabilities. Furthermore, preliminary experiments have shown that other downstream pressure drop considerations (besides those just across the spinning filtration disks) must be included to accurately portray the AP across the device. Further detailed quantitative investigations on a larger scale (1,000 CFM) prototype are warranted. 3 refs., 5 figs., 2 tabs

  4. Air emission points for facilities in Iowa with operating permits for Title V of the Federal Clean Air Act_considered MAJOR permits

    Data.gov (United States)

    Iowa State University GIS Support and Research Facility — Air emission points for facilities in Iowa with operating permits for Title V of the Federal Clean Air Act, considered "major" permits. Also includes emission...

  5. Proceedings of the 10th world clean air congress. Impacts and management

    Energy Technology Data Exchange (ETDEWEB)

    Kaemaeri, J.; Tolvanen, M.; Anttila, P.; Salonen, R.O. [eds.

    1995-12-31

    Rapid economical growth and expansion of human population have produced a number of environmental problems with varying geographic dimensions. While local problems remain near the pollution sources, the focus of the scientific community is more and more shifted towards regional, continental and global consequences of air pollutants. The theme of the 10th Clean Air Congress `Growing Challenges from Local to Global` reflects the growing demand from the scientific and professional community working in air pollution prevention and environmental protection - more and more complex mechanisms should be understood on a growing spatial scale. The 10th World Clean Air Congress addresses in its more than 400 presentations, documented in three Volumes of Proceedings, the history, the present and the potential futures of the air pollution problems. This volume includes all papers of paths C `Pollutant Impacts`, D `Pollution Management`, and E `Health Effects`. Path C includes numerous highly relevant papers dealing with climate change and greenhouse gases, as well as with environmental effects of air pollutants mostly on materials and vegetation. The most critical issues on air pollutant management throw light on national and regional abatement strategies and on the applicability of various tools for pollution management. The path on effects on human health includes a session on `Air pollution epidemiology` sponsored by the Economic Commission for Europe and a session on `Health effect control strategies` sponsored by the UN World Health Organization. In these sessions invited speakers describe the current understanding of human responses to air pollution exposure

  6. DEVELOPMENT OF A NOVEL FINE COAL CLEANING SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    Manoj K. Mohanty

    2005-06-01

    The goal of the proposed project was to develop a novel fine coal separator having the ability to clean 1 mm x 0 size coal in a single processing unit. The novel fine coal separator, named as EG(Enhanced Gravity) Float Cell, utilizes a centrifugal field to clean 1 mm x 250 micron size coal, whereas a flotation environment to clean minus 250 micron coal size fraction. Unlike a conventional enhanced gravity concentrator, which rotates to produce a centrifugal field requiring more energy, the EG Float Cell is fed with a tangential feed slurry to generate an enhanced gravity field without any rotating part. A prototype EG Float Cell unit having a maximum diameter of 60 cm (24 inch) was fabricated during the first-half of the project period followed by a series of exploratory tests to make suitable design modification. Test data indicated that there was a significant concentration of coarse heavy materials in the coarse tailings discharge of the EG Float Cell. The increase in weight (%) of 1 mm x 250 micron (16 x 60 mesh) size fraction from 48.9% in the feed to 72.2% in the coarse tailings discharge and the corresponding increase in the ash content from 56.9% to 87.0% is indicative of the effectiveness of the enhanced gravity section of the EG Float Cell. However, the performance of the flotation section needs to be improved. Some of the possible design modifications may include more effective air sparging system for the flotation section to produce finer bubbles and a better wash water distributor.

  7. Decision document on the revision of the VERA protocol on air cleaning technologies March

    OpenAIRE

    Mosquera Losada, J.; Edouard, N.; Guiziou, F.; Melse, R.W.; Riis, A.L.; Sommer, S.; Brusselman, E.

    2014-01-01

    In the project “ICT-AGRI: Development of harmonized sampling and measurement methods for odour, ammonia and dust emissions” different subgroups have been formed focusing on either ammonia, odour or dust. In this report, the conclusions of the ammonia subgroup regarding harmonization of measurement methods for the estimation of the ammonia removal from air cleaning technologies are summarized.

  8. 77 FR 49023 - Notice of Lodging of Consent Decree Under the Clean Air Act

    Science.gov (United States)

    2012-08-15

    ... of Lodging of Consent Decree Under the Clean Air Act Notice is hereby given that on August 9, 2012, a proposed Consent Decree signed by the plaintiff, the United States of America, and the defendants, Icicle... Consent Decree requires the defendants to pay a civil penalty of $430,000.00 and to perform...

  9. 77 FR 281 - Proposed Consent Decree, Clean Air Act Citizen Suit

    Science.gov (United States)

    2012-01-04

    ... AGENCY Proposed Consent Decree, Clean Air Act Citizen Suit AGENCY: Environmental Protection Agency (EPA). ACTION: Supplemental Notice of Proposed Consent Decree; Request for Public Comment. SUMMARY: On December... (``CAA'' or the ``Act''), 42 U.S.C. 7413(g), of a proposed consent decree to address a lawsuit filed...

  10. 76 FR 51030 - Proposed Consent Decree, Clean Air Act Citizen Suit

    Science.gov (United States)

    2011-08-17

    ... AGENCY Proposed Consent Decree, Clean Air Act Citizen Suit AGENCY: Environmental Protection Agency (EPA). ACTION: Notice of Proposed Consent Decree; Request for Public Comment. SUMMARY: In accordance with... hereby given of a proposed consent decree to address a lawsuit filed by Sierra Club in the United...

  11. 75 FR 74048 - Proposed Consent Decree, Clean Air Act Citizen Suit

    Science.gov (United States)

    2010-11-30

    ... AGENCY Proposed Consent Decree, Clean Air Act Citizen Suit AGENCY: Environmental Protection Agency (EPA). ACTION: Notice of proposed consent decree; request for public comment. SUMMARY: In accordance with... hereby given of a proposed consent decree to address a lawsuit filed by Sierra Club and...

  12. 77 FR 65684 - Proposed Consent Decree, Clean Air Act Citizen Suit

    Science.gov (United States)

    2012-10-30

    ... AGENCY Proposed Consent Decree, Clean Air Act Citizen Suit AGENCY: Environmental Protection Agency (EPA). ACTION: Notice of proposed consent decree; request for public comment. SUMMARY: In accordance with... decree, to address a lawsuit filed by Sierra Club in the United States District Court for the District...

  13. 77 FR 61027 - Notice of Lodging Proposed Consent Decree Clean Air Act

    Science.gov (United States)

    2012-10-05

    ... of Lodging Proposed Consent Decree Clean Air Act On October 1, 2012, the Department of Justice lodged a proposed Consent Decree with the United States District Court for the District of New Jersey in... injunctive relief. Pursuant to the Decree, Durand will pay a civil penalty of $300,000 (based on...

  14. 77 FR 73029 - Proposed Consent Decree, Clean Air Act Citizen Suit

    Science.gov (United States)

    2012-12-07

    ... AGENCY Proposed Consent Decree, Clean Air Act Citizen Suit AGENCY: Environmental Protection Agency (EPA). ACTION: Notice of proposed consent decree; request for public comment. SUMMARY: In accordance with... proposed consent decree to address a lawsuit filed by Sierra Club in the United States District Court...

  15. 77 FR 39493 - Proposed Consent Decree, Clean Air Act Citizen Suit

    Science.gov (United States)

    2012-07-03

    ... AGENCY Proposed Consent Decree, Clean Air Act Citizen Suit AGENCY: Environmental Protection Agency (EPA). ACTION: Notice of proposed consent decree; request for public comment. SUMMARY: In accordance with... decree, to address a lawsuit filed by Sierra Club in the United States District Court for the District...

  16. 76 FR 58808 - Proposed Consent Decree, Clean Air Act Citizen Suit

    Science.gov (United States)

    2011-09-22

    ... AGENCY Proposed Consent Decree, Clean Air Act Citizen Suit AGENCY: Environmental Protection Agency (EPA). ACTION: Notice of proposed consent decree; Request for public comment. SUMMARY: In accordance with... proposed partial consent decree, to address a lawsuit filed by Sierra Club in the United States...

  17. 76 FR 75544 - Proposed Consent Decree, Clean Air Act Citizen Suit

    Science.gov (United States)

    2011-12-02

    ... AGENCY Proposed Consent Decree, Clean Air Act Citizen Suit AGENCY: Environmental Protection Agency (EPA). ACTION: Notice of Proposed Consent Decree; Request for Public Comment. SUMMARY: In accordance with... hereby given of a proposed consent decree to address a lawsuit filed by National Parks...

  18. 75 FR 49947 - Notice of Lodging of Proposed Consent Decree Under the Clean Air Act

    Science.gov (United States)

    2010-08-16

    ... of Lodging of Proposed Consent Decree Under the Clean Air Act Notice is hereby given that on August 6, 2010, a proposed Consent Decree in United States v. Premix, Inc., Civil Action No. 1:10-cv- 01732-DAP... Section 114 of the CAA, 33 U.S.C. 7414. Under the proposed Consent Decree, Premix is required to...

  19. 75 FR 74046 - Proposed Consent Decree, Clean Air Act Citizen Suit

    Science.gov (United States)

    2010-11-30

    ... AGENCY Proposed Consent Decree, Clean Air Act Citizen Suit AGENCY: Environmental Protection Agency (EPA). ACTION: Notice of Proposed Consent Decree; Request for Public Comment. SUMMARY: In accordance with... proposed consent decree, to address a lawsuit filed by WildEarth Guardians: WildEarth Guardians v....

  20. 78 FR 24436 - Notice of Lodging of Proposed Consent Decree Under the Clean Air Act

    Science.gov (United States)

    2013-04-25

    ... of Lodging of Proposed Consent Decree Under the Clean Air Act On April 19, 2013, the Department of Justice lodged a proposed consent decree with the United States District Court for the District of... No. 202-1. The proposed consent decree between the United States and CEMEX, Inc. settles...

  1. 78 FR 16667 - Proposed Consent Decree, Clean Air Act Citizen Suit

    Science.gov (United States)

    2013-03-18

    ... AGENCY Proposed Consent Decree, Clean Air Act Citizen Suit AGENCY: Environmental Protection Agency (EPA). ACTION: Notice of proposed consent decree; request for public comment. SUMMARY: In accordance with... proposed consent decree to address a lawsuit filed by Preserve Pepe'ekeo Health and Environment in...

  2. 77 FR 45605 - Proposed Consent Decree, Clean Air Act Citizen Suit

    Science.gov (United States)

    2012-08-01

    ... AGENCY Proposed Consent Decree, Clean Air Act Citizen Suit AGENCY: Environmental Protection Agency (EPA). ACTION: Notice of Proposed Consent Decree; Request for Public Comment. SUMMARY: In accordance with... hereby given of a proposed consent decree to address a lawsuit filed by Sierra Club in the United...

  3. 77 FR 66978 - Proposed Consent Decree, Clean Air Act Citizen Suit

    Science.gov (United States)

    2012-11-08

    ... AGENCY Proposed Consent Decree, Clean Air Act Citizen Suit AGENCY: Environmental Protection Agency (EPA). ACTION: Notice of proposed consent decree; request for public comment. SUMMARY: In accordance with... decree to resolve a lawsuit filed by the Environmental Integrity Project, Sierra Club, and Texas...

  4. 77 FR 43859 - Notice of Lodging of a Consent Decree Under the Clean Air Act

    Science.gov (United States)

    2012-07-26

    ... of Lodging of a Consent Decree Under the Clean Air Act Notice is hereby given that on July 2, 2012, a proposed Consent Decree in the case of United States v. Hercules Incorporated, No. 3:12CV483, was lodged... proposed Consent Decree requires the Defendant to pay a civil penalty of $175,000, and to implement...

  5. 76 FR 75545 - Proposed Consent Decree, Clean Air Act Citizen Suit

    Science.gov (United States)

    2011-12-02

    ... AGENCY Proposed Consent Decree, Clean Air Act Citizen Suit AGENCY: Environmental Protection Agency (EPA). ACTION: Notice of proposed consent decree; request for public comment. SUMMARY: In accordance with... hereby given of a proposed consent decree to address a lawsuit filed by El Comit para el Bienestar...

  6. 78 FR 21419 - Notice of Proposed Consent Decree Under the Clean Air Act

    Science.gov (United States)

    2013-04-10

    ... of Proposed Consent Decree Under the Clean Air Act On April 4, 2013, the Department of Justice lodged a proposed Consent Decree with the United States District Court for the Eastern District of Missouri...'') requirements of Section 112(r)(7) of the Act. The proposed Consent Decree, which resolves all of these...

  7. European Commission as landlord. Integrated strategy for clean air in Europe

    International Nuclear Information System (INIS)

    An overview is given of the research programme Clean Air For Europe (CAFE), recently started by the European Commission. Attention is paid to the necessity of this programme, its chances for success, the planned activities, expected results, and the organization of the programme

  8. 78 FR 38074 - Notice of Lodging of Proposed Consent Decree Under the Clean Air Act

    Science.gov (United States)

    2013-06-25

    ... Puget Sound Clean Air Agency are parties to the proposed Decree. To reduce NO X emissions, the proposed Decree would require Ash Grove to install new, modern pollution controls on nine of the kilns; shut down... reduce SO 2 emissions and would require modern pollution controls to reduce PM emissions at all...

  9. 78 FR 1759 - Notice of Approval of Clean Air Act Outer Continental Shelf Minor Source/Title V Minor Permit...

    Science.gov (United States)

    2013-01-09

    ... From the Federal Register Online via the Government Publishing Office ENVIRONMENTAL PROTECTION AGENCY 40 CFR PART 52 Notice of Approval of Clean Air Act Outer Continental Shelf Minor Source/Title V... for minor modifications of Clean Air Act Outer Continental Shelf (``OCS'') Minor Source/Title V...

  10. ESTIMATES OF THE ATMOSPHERIC DEPOSITION OF SULFUR AND NITROGEN SPECIES: CLEAN AIR STATUS AND TRENDS NETWORK. 1990 THROUGH 2000

    Science.gov (United States)

    The Clean Air Status and Trends Network (CASTNet) was established by EPA in response to the requirements of the 1990 Clean Air Act Amendments. To satisfy these requirements CASTNet was designed to assess and report on geographic patterns and long-term, temporal trends in ambient ...

  11. Evaluating the Impact of Air Pollution on Human Health in China: the Price of Clean Air

    Science.gov (United States)

    Wang, X.; Mauzerall, D. L.; Hu, Y.; Russell, A. G.; Woo, J.; Streets, D. G.

    2003-12-01

    Population growth, rapid urbanization and economic development are contributing to increased energy consumption in China. One of the unintended consequences is poor air quality due to a lack of environmental controls. The coal dependent energy structure in China only worsens the situation. Quantification of the environmental costs resulting from air pollution is needed in order to provide a mechanism for making strategic energy policy that accounts for the life-cycle cost of energy use. However, few such studies have been conducted for China that examine the entire energy system. Here we examine the extent to which public health has been compromised due to elevated air pollution and how China could incorporate environmental costs into future energy and environmental policies. Taking the Shandong region in eastern China as a case study, we develop a high-resolution regional inventory for anthropogenic emissions of NOx, CO, PM2.5, PM10, VOCs, NH3 and SO2. SMOKE (Sparse Matrix Operator Kernel Emissions Modeling System) is used to process spatial and temporal distributions and chemical speciation of the regional emissions, MM5 (the Fifth-Generation NCAR/Penn State Meso-scale Model, Version 3) is used to generate meteorology and Models3/CMAQ (Community Multi-scale Air Quality Modeling System) is used to simulate ambient concentrations of particulates and other gaseous species in this region. We then estimate the mortality and morbidity in this region resulting from exposure to these air pollutants. We also estimate the monetary values associated with the resulting mortality and morbidity and quantify the contributions from various economic sectors (i.e. power generation, transportation, industry, residential and others). Finally, we examine the potential health benefits that adoption of best available or advanced energy (coal-based, in particular) and environmental technologies in different sectors could bring about. The results of these analyses are intended to provide

  12. Research for a clean and large throughput differential pumping system

    International Nuclear Information System (INIS)

    The research is to design a differential pumping system not only to achieve the pressure transition with a large throughput, but also to achieve a clean system without oil vapour contamination. In the paper, the pressure in differential stages are calculated; the differential pumping system design and equipment choice are introduced; the tests of MBP, a new kind of molecular-drag pump with large throughout and clean vacuum are described and the system experiment result and analysis is presented

  13. Impact of the 1990 Clean Air Act amendments to the biomass industry

    International Nuclear Information System (INIS)

    The direct impacts of the Clean Air Act on the existing biomass industry will be focused in four areas: Title I (nonattainment), Title III (air toxics), Title V (operating permits) and Title VII (enforcement). These four Titles will result in tighter emission limitations and other requirements on existing sources of air pollution. Two other areas should provide incentives for new biomass utilization. Title II (mobile sources) will promote the development of a clean fuels program; biomass is expected to play a key role as ethanol fuel resources are explicitly promoted by the Act. Title IV (acid rain control) will encourage the generation of power through renewable energy sources, including biomass. While there are several new requirements which will require industry to tighten controls and reduce emissions, there are also significant benefits to the biomass industry as well. A Title by Title description explains the applicable new requirements and the potential economic opportunities

  14. Excess-air incineration with high temperature filtering for efficient off-gas cleaning

    International Nuclear Information System (INIS)

    When SGN started work on volume reduction of low-level and intermediate-level radioactive wastes in the early 1960s, in collaboration with the French Atomic Energy Commission (CEA), incineration was relatively undeveloped but its potential efficiency was immediately recognized. The incinerators then available divided more or less into proven designs used in municipal refuse incineration and so-called advanced systems: SGN's initial impression was that systems for municipal refuse incineration could be readily adapted to handle combustible nuclear wastes. These systems mainly employed excess-air fixed-bed combustion, rotary furnaces or fluidized-bed combustion, sometimes with partial or total pyrolysis. The ''advanced'' systems proposed by various inventors were far more sophisticated but, due to a lack of industrial experience, were often designed with inadequate regard to human safety. The result was a number of serious accidents, including some deaths. Nuclear-grade incineration was a rather esoteric subject at the time. Standard incinerators were not designed to handle radioactive wastes. They lacked essential safety features (e.g. leaktightness) and did not provide for repair and maintenance after contamination nor for affordable dismantling at end of life. Off-gas cleaning had neither the efficiency nor safety required in the nuclear industry. Extensive automation of control and monitoring was not envisaged, because unnecessary in traditional applications

  15. Give clean air the economic value it deserves

    International Nuclear Information System (INIS)

    India contributes more to the management of the atmosphere than a country like the Netherlands. This is not to the credit of the Indian government; rather, it is merely a consequence of poverty. Poor people use almost no fossil fuels and emit almost no CO2. Paying developing countries for this environmental service to the world community would create a financial incentive to continue to provide this service in the future, while at the same time generating additional funds to improve the living standards of the poorest people. The attractiveness of this approach depends on one important assumption: the conventional development path - economic growth implies emissions - must be replaced by a sustainable development path delinks economic growth from increasing emissions. Rich industrialised countries also have an interest in such decoupling. The compensation they pay the developing countries would fall proportionately to the reduction of their CO2 emissions. So an incentive is created on both sides to switch over to a low-carbon energy strategy. After the completion of this transition, every country can use as much energy as it wants, because energy consumption would then no longer cause CO2 emissions. This is the picture of the future to which the United Air Fund aspires

  16. Emission allowance trading under the Clean Air Act Amendments: An incentive mechanism for the adoption of Clean Coal Technologies

    International Nuclear Information System (INIS)

    Title IV of the Clean Air Act Amendments of 1990 (P.L. 101-549) uses tradeable SO2 allowances as a means of reducing acidic emissions from the electricity generating industry. The use of emission allowances generates two important results; first, utilities are given the flexibility to choose their optimal (least cost) compliance strategies and second, the use of emission allowances creates greater incentives for the development and commercialization of innovative emissions control technology. Clean Coal Technologies (CCTs) are able to generate electricity more efficiently, use a wide variety of coal grades and types, and dramatically reduce emissions of SO2, NOx, CO2, and PM per kWh. However, development and adoption of the technology is limited by a variety of regulatory and technological risks. The use of SO2 emission allowances may be able to provide incentives for utility (and nonutility) adoption of this innovative technology. Emission allowances permit the utility to minimize costs on a systemwide basis and provides rewards for addition emission reductions. As CCTs are a more efficient and low emitting source of electricity, the development and implementation of this technology is desirable. This paper will explore the relationship between the incentives created by the SO2 allowance market and CCT development. Regulatory hindrances and boons for the allowance market shall also be identified to analyze how market development, state mandates, and incentive regulation will effect the ability of allowances to prompt CCT adoption

  17. New trends in the Belgian programme on nuclear air cleaning technology

    International Nuclear Information System (INIS)

    In the Belgian Programme on nuclear air cleaning technology the Mercurex process has been developed to trap iodine compounds from dissolver off-gases. Krypton is removed with the help of a cryogenic distillation unit. The various gas cleaning units have been integrated in a gas purification test loop for dissolver off-gas at a through put of 25 m3 gas h-1. The separation of tritium from liquid reprocessing effluents is being developed according to the ELEX-process. New research is started on the capture of semi-volatile ruthenium compounds

  18. Investigation of efficiency of air cleaning from acetone using a segmental construction biofilter

    Directory of Open Access Journals (Sweden)

    Denas Bacevičius

    2015-10-01

    Full Text Available Volatile organic compounds, e. g. acetone, have a direct impact on climate change, decrease of ozone in the air, and on the growth of greenhouse effect. One of the most popular air purifying methods from VOC is a biological air cleaning. Experimental investigations were conducted to determine the efficiency of the new structure of biofilter with polypropylene plates segments. During the investigations the efficiency of segmental construction biofilter of air purification at different initial concentrations of pollutants was determined. Different concentrations of pollutants were estimated during the acetone dilution with water. During the tests the efficiency of biofilter air purification from acetone vapor and its change under different concentrations of vapors was set. Based on test results, the maximum efficiency of biofilter air purification was up to 93%. Studies have shown that increasing the allowable pollutant concentration, the efficiency of air purification unit decreases. Increasing the concentration of supplied acetone vapor into the biofilter from 232 to 701 mg/m3, cleaning efficiency decreased from 92.8 to 82.3%. Since microorganisms fail to oxidize organic compounds, the filter works better at lower initial concentrations of pollutants.

  19. Impact of emerging clean vehicle system on water stress

    International Nuclear Information System (INIS)

    Graphical abstract: Display Omitted - Highlights: • Clean vehicles may increase US water consumption up to 2810 billion gallons/year. • Large-scale clean vehicle adoption could lead to severe regional water stress. • Fuel choice for clean vehicle is crucial in minimizing regional water stress. • Regional optimization illustrated the importance of regional consideration. - Abstract: While clean vehicles (i.e., vehicles powered by alternative fuels other than fossil fuels) offer great potential to reduce greenhouse gas emissions from gasoline-based vehicles, the associated impact on water resources has not yet been fully assessed. This research provides a systematic evaluation of the impact of a fully implemented clean vehicle system on national and state-level water demand and water stress. On the national level, based on existing policies, transitioning the current gasoline-based transportation into one with clean vehicles will increase national annual water consumption by 1950–2810 billion gallons of water, depending on the market penetration of electric vehicles. On the state level, variances of water efficiency in producing different fuels are significant. The fuel choice for clean vehicle development is especially crucial for minimizing water stress increase in states with already high water stress, high travel demands, and significant variations in water efficiency in producing different alternative fuels. Current development of clean vehicle infrastructure, however, has not reflected these state-level variations. This study takes an optimization approach to further evaluate impacts on state-level water stress from a fully implemented clean vehicle system and identified potential roles (fuel producer or consumer) states may play in real world clean vehicle development scenario. With an objective of minimizing overall water stress impact, our optimization model aims to provide an analytical framework to better assess impacts on state-level water

  20. Air Facility System (AFS) Widget

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Air Facility System (AFS) widget allows users to enter a specific location and retrieve facilities in the area of interest for stationary sources of air...

  1. Government's actions on clean air in the Greater Toronto Area 2003

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-12-01

    The quality of the air we breathe is closely related to our quality of life. Measures are being implemented in the Greater Toronto Area (GTA) in an effort to curb smog and its associated health impacts. A comprehensive description of clean air initiatives being undertaken by members of the GTA Clean Air Council (CAC) is provided in this report. The first section of the report deals with joint actions undertaken by members of the GTA-CAC, while clean air initiatives of each individual member jurisdiction are included in the following sections of the report. The initiatives were divided into five themes: transportation; energy; business, industry, and government; natural and built environment; and education and outreach. The transportation category deals with actions on regulatory, policy, or research and development work related to any mode of transportation, not including infrastructure or improvements. The energy category provides information on institutional energy efficiency improvements and energy procurement practices. Also listed in this category are power plant investments and retrofits, building energy improvements and purchases of green power and renewable energy. The business, industry and government category presents information on the development of standards and practices, agricultural practices and landfill methane practices, and green power purchase policies. Natural and built environment issues deal with land use planning, infrastructure investments and improvements, naturalization and tree planting, and environmental assessments. Training, awareness, smog alert response plans, advertising campaigns, employee incentives and benefits were discussed under the education and outreach banner. refs.

  2. Clean/alternative fueled fleet programs - 1990 Amendments to the Clean Air Act, the Colorado Air Pollution Prevention and Control Act, and Denver City and County regulations

    International Nuclear Information System (INIS)

    Despite substantial regulations for nearly two decades, attainment of this ambient standards for ozone and carbon monoxide (CO) remain difficult goals to achieve, Even with of ozone precursors and CO. The 1990 Amendments to the Clean Air Act (CAA90) prescribe further reductions of mobile source emissions. One such reduction strategy is using clean fuels, such as methanol, ethanol, or other alcohols (in blends of 85 percent or more alcohol with gasoline or other fuel), reformulated gasoline or diesel, natural gas, liquified petroleum gas, hydrogen, or electricity. There are regulatory measures involving special fuels which will be required in areas heavily polluted with ozone and CO. The state of Colorado recently passed the 1992 Air Pollution Prevention and Control Act which included provisions for the use of alternative fuels which will be implemented in 1994. In addition to adhering to the Colorado state regulations, the city and county of Denver also have regulations pertaining to the use of alternative fuels in fleets of 10 or more vehicles. Denver's program began in 1992. This paper will address the issue of fleet conversion and its impact on industry in Colorado, and Denver in particular

  3. Balanced-Rotating-Spray Tank-And-Pipe-Cleaning System

    Science.gov (United States)

    Thaxton, Eric A.; Caimi, Raoul E. B.

    1995-01-01

    Spray head translates and rotates to clean entire inner surface of tank or pipe. Cleansing effected by three laterally balanced gas/liquid jets from spray head that rotates about longitudinal axis. Uses much less liquid. Cleaning process in system relies on mechanical action of jets instead of contaminant dissolution. Eliminates very difficult machining needed to make multiple converging/diverging nozzles within one spray head. Makes nozzle much smaller. Basic two-phase-flow, supersonic-nozzle design applied to other spray systems for interior or exterior cleaning.

  4. Manual for THOR-AirPAS - air pollution assessment system

    DEFF Research Database (Denmark)

    Jensen, Steen Solvang; Ketzel, Matthias; Brandt, Jørgen;

    The report provides an outline of the THOR-AirPAS - air pollution assessment system and a brief manual for getting started with the air quality models and input data included in THOR-AirPAS.......The report provides an outline of the THOR-AirPAS - air pollution assessment system and a brief manual for getting started with the air quality models and input data included in THOR-AirPAS....

  5. Public Utility Commission implementation of the Clean Air Act's allowance trading program

    International Nuclear Information System (INIS)

    Title IV of the Clean Air Act Amendments of 1990 (CAAA), 'Acid Deposition Control,' will reduce by the year 2000 annual sulfur dioxide emissions by 10 million tons below the 1980 level, and nitrogen oxide emissions by 2 million tons. Emissions of sulfur dioxide will then be limited to 8.95 million tons per year after 2000. To control sulfur dioxide emissions, Title IV created a new regulatory instrument -- an emission allowance or credit -- that electric power producers (utilities and others) will be required to possess and expend to emit sulfur dioxide into the atmosphere. Electric utilities and others will be allowed to buy and sell the emission allowances in an allowance trading system. Cost estimates of implementing Title IV provisions put the cost 50 to 75 percent higher than with the allowance trading system. Estimates of this potential savings vary from 1 to 3 billion dollars annually. This report discusses the administrative roles of various agencies in implementing Title IV and allocating the emission allowance. The cost of compliance and the effect of compliance on the utilities industry is discussed

  6. A Demand Forecasting System for Clean-Fuel Vehicles

    OpenAIRE

    Brownstone, David; Bunch, David S.; Golob, Thomas F.

    1994-01-01

    This paper describes an ongoing project to develop a demand forecasting model for clean-fuel vehicles in California. Large-scale surveys of both households and commercial fleet operators have been carried out. These data are being used to calibrate a new micro-simulation based vehicle demand forecasting system. Based on pre-specified attributes of future vehicles (including specified clean-fueled vehicle incentives), the system will produce annual forecasts of new and used vehicle demand by t...

  7. Performance evaluation of air cleaning devices of an operating low level radioactive solid waste incinerator

    International Nuclear Information System (INIS)

    Particle removal efficiencies of a cyclone separator, baghouse filters and a high efficiency particulate activity (HEPA) filter bank of an incinerator have been determined during the incineration of combustible low level solid radioactive wastes with surface dose of 20 - 50 gy/h. Experimental runs have been carried out to collect the particulates in various aerodynamic size ranges using an eight stage Andersen sampler and a low pressure impactor (LPI) while the incinerator is in operation. The collection efficiencies of the cyclone, baghouse and HEPA filters have been found to be 100 per cent for particles of size greater than 4.7, 2.1 and 1.1 μm respectively. The results of our investigations indicate that the air cleaning devices of the incinerator are working according to their design criteria. The data will be useful in the design and operation of air cleaning devices for toxic gaseous effluents. (author). 3 refs., 2 figs., 1 tab

  8. Indoor secondary pollutants from cleaning product and air freshener use in the presence of ozone

    DEFF Research Database (Denmark)

    Singer, B.C.; Coleman, B.K.; Destaillats, H.;

    2006-01-01

    This study investigated the formation of secondary pollutants resulting from household product use in the presence of ozone. Experiments were conducted in a 50-m(3) chamber simulating a residential room. The chamber was operated at conditions relevant to US residences in polluted areas during warm......-weather seasons: an air exchange rate of 1.0 h(-1) and an inlet ozone concentration of approximately 120 ppb, when included. Three products were used in separate experiments. An orange oil-based degreaser and a pine oil-based general-purpose cleaner were used for surface cleaning applications. A plug-in scented......-oil air freshener (AFR) was operated for several days. Cleaning products were applied realistically with quantities scaled to simulate residential use rates. Concentrations of organic gases and secondary organic aerosol from the terpene-containing consumer products were measured with and without ozone...

  9. An efficient, environmentally acceptable, clean up system for well completions

    Energy Technology Data Exchange (ETDEWEB)

    Berg, Oe.; Saasen, A.

    1996-12-31

    Evaluation of different casing cleaning fluid systems has been a difficult task due to the lack of a standardised laboratory measurement technique for technical performance. In order to meet the need for a reliable evaluation of different chemicals and fluid systems used in casing cleaning, a laboratory procedure for the evaluation of casing cleaning chemicals has been developed. This procedure has been successfully applied in the development of a new environmentally acceptable casing cleaning fluid system. Two different procedures are presented. An old method where the drilling fluid was displaced down the annulus and up the drill string was found to be ineffective compared to a method where the drilling fluid was displaced up in the annulus. The application of this procedure together with the use of the new chemical additive has reduced the cost of casing cleanup operations in the range of 30-40%. 10 refs., 1 fig., 4 tabs.

  10. An efficient, environmentally acceptable, clean up system for well completions

    International Nuclear Information System (INIS)

    Evaluation of different casing cleaning fluid systems has been a difficult task due to the lack of a standardised laboratory measurement technique for technical performance. In order to meet the need for a reliable evaluation of different chemicals and fluid systems used in casing cleaning, a laboratory procedure for the evaluation of casing cleaning chemicals has been developed. This procedure has been successfully applied in the development of a new environmentally acceptable casing cleaning fluid system. Two different procedures are presented. An old method where the drilling fluid was displaced down the annulus and up the drill string was found to be ineffective compared to a method where the drilling fluid was displaced up in the annulus. The application of this procedure together with the use of the new chemical additive has reduced the cost of casing cleanup operations in the range of 30-40%. 10 refs., 1 fig., 4 tabs

  11. Economic impacts of EU clean air policies assessed in a CGE framework

    OpenAIRE

    VRONTISI ZOI; Abrell, Jan; NEUWAHL FREDERIK; Saveyn, Bert; Wagner, Fabian

    2016-01-01

    This paper assesses the macroeconomic and sectoral impacts of the "Clean Air Policy Package" proposed by the European Commission in December 2013. The analysis incorporates both the expenditures necessary to implement the policy by 2030 and the resulting positive feedback effects on human health and crop production. A decomposition analysis identifies the important drivers of the macroeconomic impacts. We show that while expenditure on pollution abatement is a cost for the abating sector...

  12. Clean-air legislation will buoy U.S. gas processing

    International Nuclear Information System (INIS)

    This paper reports on the effects of recent U.S. clean-air legislation on NGL demand and pricing. Demand for all NGL products will be firm throughout the 1990s. Increased requirements for butane as methyl tertiary butyl ether (MTBE) feedstock will strengthen butane prices. Higher base-load requirements for propane in new NGL-based olefin plants will also have a positive impact on propane prices

  13. Regulating Greenhouse Gases from Coal Power Plants under the Clean Air Act

    OpenAIRE

    Joshua Linn; Erin Mastrangelo; Dallas Burtraw

    2014-01-01

    The Clean Air Act has assumed the central role in US climate policy, directing the development of regulations governing greenhouse gas emissions from existing coal-fired power plants. This paper uses a model of power plant operation and efficiency investments to compare the cost-effectiveness of alternative policies to reduce greenhouse gas emissions from coal plants. We empirically estimate the key model parameters from a data set of the operation of coal-fired generating units over 25 years...

  14. Clean air suits vs scrub suits: what are the benefits of using them for infection control in hospitals?

    OpenAIRE

    Abreu, Maria José

    2014-01-01

    Experts in infection control are often asked about issues related to the use of scrubs and clean air suits in the operating room (OR). So far there is no clear explanation or mandatory obligation why the surgical team has to wear clean air suits or scrub suits in the operating rooms (OR´s) and more importantly, what are the main differences between these two type of clothing. There is a general perception that the two are equal or very similar. So, what are clean air suits and scrub suits? Wh...

  15. Preservation of atomically clean silicon surfaces in air by contact bonding

    DEFF Research Database (Denmark)

    Grey, Francois; Ljungberg, Karin

    1997-01-01

    ordered atomic structure of the surfaces is protected from oxidation, even after the bonded samples have been in air for weeks. Further, we show that silicon surfaces that have been cleaned and hydrogen-passivated in UHV can be contacted in UHV in a similarly hermetic fashion, protecting the surface...... reconstruction from oxidation in air, Contact bonding opens the way to novel applications of reconstructed semiconductor surfaces, by preserving their atomic structure intact outside of a UHV chamber. (C) 1997 American Institute of Physics....

  16. Feasibility for the medium efficiency filter as a postfilter in the air cleaning unit

    International Nuclear Information System (INIS)

    The Air Cleaning Unit (ACU) is provided in a nuclear facility to filter the radioactive materials in gaseous effluents released from the facility during normal operation and during a postulated accident. The Air Cleaning Unit (ACU) consists of pre-HEPA filters, charcoal adsorber, post HEPA filters, fans, etc. The charcoal filters keep on-site dose and off-site effluents ALARA, consistent with regulatory requirements. The function of HEPA filter downstream of charcoal(carbon) adsorber in ACU is to catch potential radioactive carbon dust and to be a backup in the event of failure of upstream HEPA. Previous Regulatory Guide use only post HEPA filter of charcoal adsorber downstream but the Regulatory Guide of current revisions allows use of 95% dust spot efficiency filters in lieu of HEPA at the downstream of the carbon adsorber. In this paper is described that the background information of filters, Current Regulatory Guide of revised by the United States Nuclear Regulatory Commission and the feasibility for the medium efficiency filter as a carbon adsorber post filter in the Air Cleaning Unit

  17. Investigation of flushing and clean-out methods for refrigeration equipment to ensure system compatibility

    Energy Technology Data Exchange (ETDEWEB)

    Byrne, J.J.; Shows, M.; Abel, M.W. [Integral Sciences Inc., Columbus, OH (United States)

    1996-04-24

    SECTION 608 of the Clean Air Act Amendments has altered much of the refrigeration service contracting industry. MCLR Project Number 660-52502 was established to examine two areas where the Amendments are influencing contractors to determine if more cost-effective service procedures might be developed. One area where existing service procedures are being revisited involves the removal of contaminants from a refrigeration system after a motor burnout. At one time, a Class 1 substance such as CFC-11 or CFC-113 was used as a flushing agent for cleaning a system after a burnout. On large systems, the compressor was disassembled, and the parts were cleaned using 1,1,1-trichloroethane (TCA) or a TCA-containing mixture. Such alternatives are seldom possible today, as the manufacture of Class 1 substances was banned on January 1, 1996. This report describes processes for mineral oil removal, process alternatives for servicing burnouts, solvents, and laboratory retrofit tests.

  18. Decision-making for complying with SO2 provisions of the Clean Air Act

    International Nuclear Information System (INIS)

    Prior to the Clean Air Act of 1990 (CAA), SO2 removal options were based on a command and control approach for each plant. This approach usually resulted in the addition of an FGD system. However, the CAA offers a market based emission allowance program which offers considerable flexibility for compliance with the new regulations. The flexibility for compliance introduces more available options into the evaluation and increases the complexity of the decision-making process. This paper discusses the methodology of a recent analysis which evaluated various strategies for meeting SO2 compliance. The importance of evaluating options based on certain goals is discussed. An overall goal was established to develop a flexible and least cost compliance plan. However, these goals need to be balanced against constraints for the utility which may include: minimizing SO2 allowance market risk; optimizing the availability, cost and timing of capital expenditures into the analysis; minimizing site impacts and construction lead time; and coordinating strategies from various units and stations into a cohesive plan

  19. The 1990 Clean Air Act Amendments and the Great Lakes economy: Challenges and opportunities

    International Nuclear Information System (INIS)

    This paper deals with the market for SO2 emission allowances over time and electric utility compliance choices. For currently high emitting plants ( > 2.5 lb SO2/MMBtu), the 1990 Clean Air Act Amendments (CAAA) provide for about twice as many SO2 allowances to be issued per year in Phase 1 (1995--1999) than in Phase 2. Also, considering the scrubber incentives in Phase 1, there is likely to be substantial emission banking for use in Phase 2. Allowance prices are expected to increase over time at a rate less than the return on alternative investments, so utilities which are risk neutral or other potential speculators in the allowance market are not expected to bank allowances. The allowances will be banked by risk averse utilities or the utilities may buy forward contracts for SO2 allowances. However, speculators may play an important role by selling forward contracts for SO2 allowances to the risk averse utilities. The Argonne Utility Simulation Model (ARGUS) is being revised to incorporate the provisions of the CAAA acid rain title and to simulate SO2 allowance prices, compliance choices, capacity expansion, system dispatch, fuel use, and emissions. The revised model (ARGUS2) incorporates unit-level performance data and can incorporate unit-specific compliance decisions when these are known. The model has been designed for convenience in analyzing alternatives scenarios (demand growth rates, technology mix, economic parameters, etc). 1 ref., 5 figs

  20. Air coolant system

    International Nuclear Information System (INIS)

    The main patent relates to a process of cooling the steam from the turbine working with a nuclear power reactor, in said process a two-phase fluid mixture is circulated inside a closed circuit between the turbine condenser and a cooling tower. The present addition to the main patent relates to a cooling system comprising instead of the vertical tower, a nearly horizontal structure open to wind, in which the air is circulated by natural convection. The lower part of said structure, according to the invention, comprises two parallel rows of nearly rectangular cooling fins and the upper part consists of two walls made antiparallel with respect to the longitudinal symmetry plane of said structure and thus forming an upwards widening, the resulting vertical planar section of the long-shaped cooling structure according to the invention assuming a venturi shape. Said type of structure a few hundred meters long but only fifty meters high is less visible in the landscape than the vertical tower, and condensation clouds are formed onside a larger surface, that is another ecological advantage

  1. Index to the 1st through 16th AEC/ERDA/DOE nuclear air cleaning conferences

    International Nuclear Information System (INIS)

    The Proceedings of the sixteen conferences comprise a vertible encyclopedia on the technology of nuclear air and gas treatment and the control of airborne nuclear waste. These Proceedings cover the history of the technology; describe most of the research and developments in the field, worldwide, since the early 1950's; describe the problems that have been encountered and the solutions found to those problems; and summarize experience with equipment and systems developed for the control of airborne radioactive wastes in laboratory, radiochemical, and reactor operations, both government and commercial. The problem with this encyclopedia is that there has been no index to it; there has been no easy way for searching it to find what was available. This index fills the gap. The first conference was an informal meeting of a number of interested parties from among the then AEC contractors. Consequently, there were no proceedings for that meeting. The subsequent conferences, with their years, locations, and Proceedings numbers, are listed. This index consists of three parts: a tabulation of papers and their authors by paper number (Part I); a tabulation of papers and their paper numbers by author (Part II); and a key-word-in context (KWIC) index of papers. The paper number is a two-part designation consisting of the number of the conference (2, 3...16) followed by the page number of the paper in the corresponding Proceedings. The author index lists each author who has participated in the air cleaning conferences over the years, and the paper index lists all authors of the respective papers. The KWIC index is, in effect, a comprehensive subject cross index; each paper is listed as many times, by keyword, as there are major terms (i.e., keywords) in its title. Although this multiple listing results in a lengthy list, it provides a very deep cross-indexing of the papers

  2. 78 FR 43880 - Request for Nominations of Experts for the Clean Air Scientific Advisory Committee (CASAC) Sulfur...

    Science.gov (United States)

    2013-07-22

    ... AGENCY Request for Nominations of Experts for the Clean Air Scientific Advisory Committee (CASAC) Sulfur... the chartered CASAC on primary (human health-based) air quality standards for sulfur oxides (SO X... six ``criteria'' air pollutants, including sulfur oxides. As a Federal Advisory Committee, the...

  3. Cleaning Products and Air Fresheners: Emissions and ResultingConcentrations of Glycol Ethers and Terpenoids

    Energy Technology Data Exchange (ETDEWEB)

    Singer, Brett C.; Destaillat, Hugo; Hodgson, Alfred T.; Nazaroff,William W.

    2005-08-01

    Experiments were conducted to quantify emissions and concentrations of glycol ethers and terpenoids from cleaning product and air freshener use in a 50-m{sup 3} room ventilated at {approx}0.5 h{sup -1}. Five cleaning products were applied full-strength (FS); three were additionally used in dilute solution. FS application of pine-oil cleaner (POC) yielded 1-h concentrations of 10-1300 {micro}g m{sup -3} for individual terpenoids, including {alpha}-terpinene (90-120), d-limonene (1000-1100), terpinolene (900-1300), and {alpha}-terpineol (260-700). One-hour concentrations of 2-butoxyethanol and/or dlimonene were 300-6000 {micro}g m{sup -3} after FS use of other products. During FS application including rinsing with sponge and wiping with towels, fractional emissions (mass volatilized/dispensed) of 2-butoxyethanol and d-limonene were 50-100% with towels retained, {approx}25-50% when towels were removed after cleaning. Lower fractions (2-11%) resulted from dilute use. Fractional emissions of terpenes from FS use of POC were {approx}35-70% with towels retained, 20-50% with towels removed. During floor cleaning with dilute solution of POC, 7-12% of dispensed terpenes were emitted. Terpene alcohols were emitted at lower fractions: 7-30% (FS, towels retained), 2-9% (FS, towels removed), and 2-5% (dilute). During air-freshener use, d-limonene, dihydromyrcenol, linalool, linalyl acetate, and {beta}-citronellol were emitted at 35-180 mg d{sup -1} over three days while air concentrations averaged 30-160 {micro}g m{sup -3}.

  4. Air conditioning system

    Science.gov (United States)

    Lowenstein, Andrew; Miller, Jeffrey; Gruendeman, Peter; DaSilva, Michael

    2005-02-01

    An air conditioner comprises a plurality of plates arranged in a successively stacked configuration with portions thereof having a spaced apart arrangement, and defining between successive adjacent pairs of plates at the spaced apart portions a first and second series of discrete alternating passages wherein a first air stream is passed through the first series of passages and a second air stream is passed through the second series of passages; and said stacked configuration of plates forming integrally therewith a liquid delivery means for delivering from a source a sufficient quantity of a liquid to the inside surfaces of the first series of fluid passages in a manner which provides a continuous flow of the liquid from a first end to a second end of the plurality of plates while in contact with the first air stream.

  5. Object Oriented Intelligent Multi-Agent System Data Cleaning Architecture To Clean Email Data

    Directory of Open Access Journals (Sweden)

    Dr. G. Arumugam,

    2010-11-01

    Full Text Available Agents are software programs that perform tasks on behalf of others and they can be used to mine data with their characteristics. Agents are task oriented with the ability to learn by themselves and they react to the situation. Learning characteristics of an agent is done by verifying its previous experience from its knowledgebase. An agent concept is a complementary approach to the Object Oriented paradigm with respect to the design and implementation of autonomous entities driven by beliefs, goals and plans. Email is one of the common means for communication via text. Email cleaning problem is formalized as non-text filtering and text normalization in a two step process. Agents incorporated in the architectural design of an Email data cleaning process combines both the features of Multi-Agent System (MAS Framework and MAS with learning (MASL Framework. MAS framework reduces the development time and the complexity of implementing thesoftware agents. The MAS-L framework incorporates the intelligence and learning properties of software agents. MAS-L Framework makes use of the Decision Tree learning and an evaluation function to decide thenext best decision that applies to the machine learning technique. This paper proposes the design for Multi- Agent based Data Cleaning Architecture that incorporates the structural design of agents into object model. The design of an architectural model for Multi-Agent based Data Cleaning inherits the features of the MAS and uses the MAS-L framework to design the intelligence and learning characteristics.

  6. Supercritical CO2 Cleaning System for Planetary Protection and Contamination Control Applications

    Science.gov (United States)

    Lin, Ying; Zhong, Fang; Aveline, David C.; Anderson, Mark S.

    2012-01-01

    Current spacecraft-compatible cleaning protocols involve a vapor degreaser, liquid sonication, and alcohol wiping. These methods are not very effective in removing live and dead microbes from spacecraft piece parts of slightly complicated geometry, such as tubing and loosely fitted nuts and bolts. Contamination control practices are traditionally focused on cleaning and monitoring of particulate and oily residual. Vapor degreaser and outgassing bakeout have not been proven to be effective in removing some less volatile, hydrophilic biomolecules of significant relevance to life detection. A precision cleaning technology was developed using supercritical CO2 (SCC). SCC is used as both solvent and carrier for removing organic and particulate contaminants. Supercritical fluid, like SCC, is characterized by physical and thermal properties that are between those of the pure liquid and gas phases. The fluid density is a function of the temperature and pressure. Its solvating power can be adjusted by changing the pressure or temperature, or adding a secondary solvent such as alcohol or water. Unlike a regular organic solvent, SCC has higher diffusivities, lower viscosity, and lower surface tension. It readily penetrates porous and fibrous solids and can reach hard-to-reach surfaces of the parts with complex geometry. Importantly, the CO2 solvent does not leave any residue. The results using this new cleaning device demonstrated that both supercritical CO2 with 5% water as a co-solvent can achieve cleanliness levels of 0.01 mg/cm2 or less for contaminants of a wide range of hydrophobicities. Experiments under the same conditions using compressed Martian air mix, which consists of 95% CO2, produced similar cleaning effectiveness on the hydrophobic compounds. The main components of the SCC cleaning system are a high-pressure cleaning vessel, a boil-off vessel located downstream from the cleaning vessel, a syringe-type high-pressure pump, a heat exchanger, and a back pressure

  7. CLEAN-ROADS project: air quality considerations after the application of a novel MDSS on winter road maintenance activities

    Science.gov (United States)

    Pretto, Ilaria; Malloci, Elisa; Tonidandel, Gabriele; Benedetti, Guido; Di Napoli, Claudia; Piazza, Andrea; Apolloni, Roberto; Cavaliere, Roberto

    2016-04-01

    With this poster we present the environmental benefit on air quality derived by the application of the CLEAN-ROADS pilot project. The CLEAN-ROADS project addresses the problem of the environmental pollution caused by de-icing salts during winter road maintenance activities in the Province of Trento (Italy). A demonstrative Maintenance Decision Support System (MDSS) has been developed in order to improve the intervention procedures of the road management service. Specifically it aims to optimize the efficiency of how available resources (e.g., salt consumption) are currently used while guaranteeing the current level of road safety. The CLEAN-ROADS project has been tested and validated on a test area located in a valley bottom (Adige Valley), where the highest optimization margins are to be expected. The project supports current road maintenance practices, which has proved to be reliable and accurate, with a new scalable and energy-efficient road monitoring system. This system is based on a network of road weather stations (road weather information system, RWIS) installed on the test route. It is capable to collect real-time data about the road conditions and to perform short-term and now-cast road weather forecasts, which actively integrate weather data and bulletins covering the target area [1]. This poster presents the results obtained from a three-year monitoring activity with the aim to (1) determine the impact of de-icing salts on air quality and (2) quantify the improvements obtained by the application of the CLEAN-ROADS project on air quality. The Ambient Air Quality and Cleaner Air for Europe Directive (2008/50/EC) states that contributions to exceedances of particulate matter PM10 limit values that are attributable to road winter salting may be subtracted when assessing compliance with air quality limit values, once provided that reasonable measures have been taken to lower concentrations [2]. As the de-icing salts used in road maintenance are mainly based

  8. Stopping air pollution at its source; Clean Air Program explanatory notes

    Energy Technology Data Exchange (ETDEWEB)

    1987-01-01

    An Ontario government review of its air pollution control program found that Regulation 308, the principal regulation relating to air pollution control, needed updating to provide additional protection to the people and environment. These explanatory notes provide a summary of the discussion paper, which presents an overview of the proposed amendments to Regulation 308 and a summary of objectives, in order to stimulate comments and criticism. The notes list the objections to the old regulation and briefly describe the objectives of the proposed amendments in the areas of emission limits, classification of contaminants, levels of pollution control, and ambient air standards. Definitions of terms and phraseology are also included.

  9. Accuracy of Linear Depolarisation Ratios in Clean Air Ranges Measured with POLIS-6 at 355 and 532 NM

    Directory of Open Access Journals (Sweden)

    Freudenthaler Volker

    2016-01-01

    Full Text Available Linear depolarization ratios in clean air ranges were measured with POLIS-6 at 355 and 532 nm. The mean deviation from the theoretical values, including the rotational Raman lines within the filter bandwidths, amounts to 0.0005 at 355 nm and to 0.0012 at 532 nm. The mean uncertainty of the measured linear depolarization ratio of clean air is about 0.0005 at 355 nm and about 0.0006 at 532 nm.

  10. Proceedings of the 21st DOE/NRC nuclear air cleaning conference; Volume 2, Sessions 9--16

    Energy Technology Data Exchange (ETDEWEB)

    First, M.W. [ed.] [Harvard Univ., Boston, MA (United States). Harvard Air Cleaning Lab.

    1991-02-01

    The 21st meeting of the Department of Energy/Nuclear Regulatory Commission (DOE/NRC) Nuclear Air Cleaning Conference was held in San Diego, CA on August 13--16, 1990. The proceedings have been published as a two volume set. Volume 2 contains sessions covering adsorbents, nuclear codes and standards, modelling, filters, safety, containment venting and a review of nuclear air cleaning programs around the world. Also included is the list of attendees and an index of authors and speakers. (MHB)

  11. Interaction between Titles 2 and 3 of the Clean Air Act as amended, 1990

    Energy Technology Data Exchange (ETDEWEB)

    Szpunar, C.B.

    1996-02-01

    This report examines Some issues that would I affect the refining industry if the requirements for hazardous air pollutants set out in Title III of the Clean Air Act Amendments were to impede the market entrance of oxygenated fuels, as me; required by Title II. It describes the mandate for reformulated gasoline; considers gasoline characteristics in light of component shifts in refining; examines the supply of, demand for, and cost of various feedstocks and blendstocks; and identifies the emissions and atmospheric impacts that might result from the production and use of reformulated gasoline. Attention is focused on methanol and MTBE, two potential blendstocks that are also hazardous air pollutants, and on maximum achievable control technology standards, which might be applied to the stationary sources that produce them.

  12. Interaction between Titles 2 and 3 of the Clean Air Act as amended, 1990

    International Nuclear Information System (INIS)

    This report examines Some issues that would I affect the refining industry if the requirements for hazardous air pollutants set out in Title III of the Clean Air Act Amendments were to impede the market entrance of oxygenated fuels, as me; required by Title II. It describes the mandate for reformulated gasoline; considers gasoline characteristics in light of component shifts in refining; examines the supply of, demand for, and cost of various feedstocks and blendstocks; and identifies the emissions and atmospheric impacts that might result from the production and use of reformulated gasoline. Attention is focused on methanol and MTBE, two potential blendstocks that are also hazardous air pollutants, and on maximum achievable control technology standards, which might be applied to the stationary sources that produce them

  13. Control System Design for a Surface Cleaning Robot

    Directory of Open Access Journals (Sweden)

    Zhai Yuyi

    2013-05-01

    Full Text Available This paper aims to study a control system for a surface cleaning robot and the focus of the study is the surface cleaning robot controller design. The structural framework of the propulsion control system of the surface robot is designed based on the principle of PWM speed control. The function of each module in the control system is divided and described in detail. A kind of thinking based on an AVR microprocessor and its software and hardware design proposals are presented. Through RS485 and PC communication according to the agreed protocol, the control system achieves robot forward, backward, turn and work operations by the use of a DC motor or stepper motor, and it can therefore more successfully realize the work of a surface cleaning robot.

  14. Recent results on cleaning and conditioning the ATF vacuum system

    International Nuclear Information System (INIS)

    Techniques for cleaning and conditioning the vacuum vessel of the Advanced Toroidal Facility (ATF) and its internal components are described. The vacuum vessel cleaning technique combines baking to 150 degree C and glow discharges with hydrogen gas. Chromium gettering is used to further condition the system. The major internal components are the anodized aluminum baffles in the Thomson scattering system, a graphite-shielded ICRF antenna, two graphite limiters, and a diagnostic graphite plate. Three independent heating systems are used to bake some of the major components of the system. The major characteristics used for assessing cleanliness and conditioning progress are the maximum pressure attained during bakeout, the results of gas analysis, and revelant plasma parameters (e.g., time to radiative decay). Details of the various cleaning and conditioning procedures and results are presented

  15. Control System Design for a Surface Cleaning Robot

    OpenAIRE

    Zhai Yuyi; Zhou Yu; Luo Huanxin; Liu Yunjia; Liu Liang

    2013-01-01

    This paper aims to study a control system for a surface cleaning robot and the focus of the study is the surface cleaning robot controller design. The structural framework of the propulsion control system of the surface robot is designed based on the principle of PWM speed control. The function of each module in the control system is divided and described in detail. A kind of thinking based on an AVR microprocessor and its software and hardware design proposals are presented. Through RS485 an...

  16. Interactions between energy efficiency and emission trading under the 1990 Clean Air Act Amendments

    International Nuclear Information System (INIS)

    The 1990 Clean Air Act Amendments affect electric utilities in numerous ways. The feature that probably has received the greatest attention is the provision to let utilities trade emissions of sulfur dioxide (SO2), while at the same time requiring them to reduce S02 emissions in 2000 by an aggregate 43%. The emission trading system was welcomed by many as a way of reducing the cost of reducing emissions, by providing greater flexibility than past approaches. This report examines some of the potential interactions between trading emissions and increasing end-use energy efficiency. The analysis focuses on emission trading in the second phase of the trading program, which begins in 2000. The aggregate effects, calculated by an emission compliance and trading model, turn out to be rather small. Aggressive improvement of end-use efficiency by all utilities might reduce allowance prices by $22/ton (1990 dollars), which is small compared to the reduction that has occurred in the estimates of future allowance prices and when compared to the roughly $400/ton price we estimate as a base case. However, the changes in the allowance market that result are large enough to affect some compliance decisions. If utilities in only a few states improve end-use efficiency aggressively, their actions may not have a large effect on the price of an allowance, but they could alter the demand for allowances and thereby the compliance decisions of utilities in other states. The analysis shows how improving electricity end-use efficiency in some states can cause smaller emission reductions in other states, relative to what would have happened without the improvements. Such a result, while not surprising given the theory behind the emission trading system, is upsetting to people who view emissions, environmental protection, and energy efficiency in moral rather than strictly economic terms

  17. The U.S. clean air act amendments of 1990: final contours of the acid rain program

    International Nuclear Information System (INIS)

    The Clean Air Act Amendments (CAAA) of 1990, enacted on November 15, 1990, created a revolutionary new approach to the control of acidic deposition, more commonly called acid rain. With the electric power industry responsible for 60 to 70 percent of the Nation's emissions of sulphur dioxide (SO2), the precursor element of acid rain, the initial program is directed toward controlling SO2 emissions from electric powerplants. Gone is the old command and control regime that relied upon governmentally mandated control techniques, often on a case-by-case basis. Instead, the Clean Air Act Amendments (CAAA) rely upon a market-based emission trading system that introduces flexibility and low cost solutions for powerplant compliance strategies. The implementation process by the U.S Environmental Protection Agency (EPA) is moving forward rapidly. One rule already has been finalized, dealing with auctions and sales. The core rules, four rules that deal with the central elements of the program, have been issued for comment and will be finalized in May or June of 1992. Other rules are still in the development stage; however, they deal with less central elements of the program and will not slow down the introduction of the emission trading system in time to meet the CAAA's statutory deadlines. 4 refs

  18. A demand forecasting system for clean-fuel vehicles

    Energy Technology Data Exchange (ETDEWEB)

    Brownstone, D.; Bunch, D.S.; Golob, T.F.

    1994-12-31

    This paper describes an ongoing project to develop a demand forecasting model for clean-fuel vehicles in California. Large-scale surveys of both households and commercial fleet operators have been carried out. These data are being used to calibrate a new micro-simulation based vehicle demand forecasting system. Based on pre-specified attributes of future vehicles (including specified clean-fueled vehicle incentives), the system will produce annual forecasts of new and used vehicle demand by type of vehicle and geographic region. The system will also forecast annual vehicle miles traveled for all vehicles and recharging demand by time of day for electric vehicles. These results are potentially useful to utility companies in their demand-side management planning, to public agencies in their evaluation incentive schemes, and to manufacturers faced with designing and marketing clean-fuel vehicles.

  19. 3D Air Quality and the Clean Air Interstate Rule: Lagrangian Sampling of CMAQ Model Results to Aid Regional Accountability Metrics

    Science.gov (United States)

    Fairlie, T. D.; Szykman, Jim; Pierce, Robert B.; Gilliland, A. B.; Engel-Cox, Jill; Weber, Stephanie; Kittaka, Chieko; Al-Saadi, Jassim A.; Scheffe, Rich; Dimmick, Fred; Tikvart, Joe

    2008-01-01

    The Clean Air Interstate Rule (CAIR) is expected to reduce transport of air pollutants (e.g. fine sulfate particles) in nonattainment areas in the Eastern United States. CAIR highlights the need for an integrated air quality observational and modeling system to understand sulfate as it moves in multiple dimensions, both spatially and temporally. Here, we demonstrate how results from an air quality model can be combined with a 3d monitoring network to provide decision makers with a tool to help quantify the impact of CAIR reductions in SO2 emissions on regional transport contributions to sulfate concentrations at surface monitors in the Baltimore, MD area, and help improve decision making for strategic implementation plans (SIPs). We sample results from the Community Multiscale Air Quality (CMAQ) model using ensemble back trajectories computed with the NASA Langley Research Center trajectory model to provide Lagrangian time series and vertical profile information, that can be compared with NASA satellite (MODIS), EPA surface, and lidar measurements. Results are used to assess the regional transport contribution to surface SO4 measurements in the Baltimore MSA, and to characterize the dominant source regions for low, medium, and high SO4 episodes.

  20. Air transport system

    CERN Document Server

    Schmitt, Dieter

    2016-01-01

    The book addresses all major aspects to be considered for the design and operation of aircrafts within the entire transportation chain. It provides the basic information about the legal environment, which defines the basic requirements for aircraft design and aircraft operation. The interactions between  airport, air traffic management and the airlines are described. The market forecast methods and the aircraft development process are explained to understand the very complex and risky business of an aircraft manufacturer. The principles of flight physics as basis for aircraft design are presented and linked to the operational and legal aspects of air transport including all environmental impacts. The book is written for graduate students as well as for engineers and experts, who are working in aerospace industry, at airports or in the domain of transport and logistics.

  1. Evaluation of pressurized water cleaning systems for hardware refurbishment

    Science.gov (United States)

    Dillard, Terry W.; Deweese, Charles D.; Hoppe, David T.; Vickers, John H.; Swenson, Gary J.; Hutchens, Dale E.

    1995-01-01

    Historically, refurbishment processes for RSRM motor cases and components have employed environmentally harmful materials. Specifically, vapor degreasing processes consume and emit large amounts of ozone depleting compounds. This program evaluates the use of pressurized water cleaning systems as a replacement for the vapor degreasing process. Tests have been conducted to determine if high pressure water washing, without any form of additive cleaner, is a viable candidate for replacing vapor degreasing processes. This paper discusses the findings thus far of Engineering Test Plan - 1168 (ETP-1168), 'Evaluation of Pressurized Water Cleaning Systems for Hardware Refurbishment.'

  2. Respiratory effects of secondhand smoke exposure among young adults residing in a "clean" indoor air state.

    Science.gov (United States)

    Lee, David J; Dietz, Noella A; Arheart, Kristopher L; Wilkinson, James D; Clark, John D; Caban-Martinez, Alberto J

    2008-06-01

    The objective of this study is to estimate the prevalence of self-reported secondhand smoke (SHS) exposures and its association with respiratory symptoms in a sample of young adults residing in a state with a partial clean indoor air law. A cross-sectional telephone survey of Florida households and a single state University was conducted in 2005. Enrolled participants between 18 and 24 years of age completed a 15-20 min interview assessing past and current SHS exposure and current respiratory symptoms (n = 1858). Approximately 60% of the sample were female; nearly 70% were non-Hispanic white, 10% were non-Hispanic Black, and 11% were Hispanic. Over two-thirds reported completing at least some college; 23% reported smoking in the past month. Nearly two-thirds (64%) reported visiting a bar or nightclub which exposed them to SHS in the previous month; nearly half (46%) reported SHS exposure while riding in automobiles; 15% reported occupational SHS exposure; and nearly 9% reported living with at least one smoker. In multivariable models, personal smoking behavior, parental smoking history, and exposure to SHS in automobiles and in bars or nightclubs were significantly associated with increased reports of respiratory symptoms. Despite residing in a "clean" indoor air state, the majority of surveyed young adults continue to report exposure to SHS, especially in automobiles and in bars, and these exposures adversely impact respiratory health. All municipalities should pursue clean indoor air legislation which does not exempt bars and restaurants. Educational campaigns directed at reducing SHS exposure in motor vehicles also are needed. PMID:18246415

  3. 76 FR 54462 - Notification of a Public Teleconference; Clean Air Scientific Advisory Committee; Air Monitoring...

    Science.gov (United States)

    2011-09-01

    ... required to consider traffic volumes, fleet mix, roadway design, traffic congestion patterns, local terrain... network in support of a newly revised National Ambient Air Quality Standard (NAAQS) for 1-hour NO 2 (75 FR... Committee (CASAC) to provide advice on EPA's draft Near-Road NO 2 Monitoring Technical Assistance...

  4. Section 112 hazardous air pollutants Clean Air Act Amendments of 1990; potential impact of fossil/NUC

    International Nuclear Information System (INIS)

    Control of hazardous air pollutants under the Clean Air Act (CAA) goes back several decades. Section 112 of the 1970 CAA as amended in 1977 served as the national statutory basis for controlling hazardous air pollutants until the most recent 1990 Amendments. Following severe criticism of the effectiveness of the Act to address hazardous air pollutant issues and a pile of seemingly never ending lawsuits challenging the regulatory process, the U.S. Congress has substantially rewritten Section 112 in the 1990 CAA Amendments. Many provisions heretofore requiring findings or regulatory decisions by the Environmental Protection Agency (EPA) Administrator are now automatic in the sense that the decisions have already been made by the US Congress legislatively. Thus, the new Section 112 has eliminated many of the existing regulatory obstacles, or safeguards; this will likely result in sweeping new regulatory programs mandating extensive controls on many industrial activities. A much needed study program to address fossil fuel fired steam electric generating units' hazardous air emissions and to identify control alternatives to regulate these emissions, if regulation is required, was incorporated into new Section 112. Because of this study, the regulatory fate of these units under the new Section 112 remains highly uncertain. An extensive regulatory program addressing hazardous air pollutants of these utility units under Section 112 would dwarf electric utility costs associated with the new acid rain control program. First, this paper identifies major provisions of the old law and the resulting regulatory status for both coal and nuclear power facilities before addressing the new Section 112 under the 1990 CAA Amendments and potential implications for electric utilities specifically

  5. Clean air policy under the UNECE Convention on long-range transboundary air pollution: how are monitoring results "translated" to policy action

    Directory of Open Access Journals (Sweden)

    Johannessen T

    2009-01-01

    Full Text Available Concerning clean air policy, under the convention on long-range transboundary air pollution, the following themes are discussed: the history of observed effects; the public awareness and concern for the ecosystem health; the current scientific evidence; the development of the critical load concept, and its application for an effects-based abatement policy.

  6. Decentralized energy systems for clean electricity access

    Science.gov (United States)

    Alstone, Peter; Gershenson, Dimitry; Kammen, Daniel M.

    2015-04-01

    Innovative approaches are needed to address the needs of the 1.3 billion people lacking electricity, while simultaneously transitioning to a decarbonized energy system. With particular focus on the energy needs of the underserved, we present an analytic and conceptual framework that clarifies the heterogeneous continuum of centralized on-grid electricity, autonomous mini- or community grids, and distributed, individual energy services. A historical analysis shows that the present day is a unique moment in the history of electrification where decentralized energy networks are rapidly spreading, based on super-efficient end-use appliances and low-cost photovoltaics. We document how this evolution is supported by critical and widely available information technologies, particularly mobile phones and virtual financial services. These disruptive technology systems can rapidly increase access to basic electricity services and directly inform the emerging Sustainable Development Goals for quality of life, while simultaneously driving action towards low-carbon, Earth-sustaining, inclusive energy systems.

  7. Seismic qualification of the air cleaning units for nuclear power plant Ulchin 5 and 6

    International Nuclear Information System (INIS)

    Seismic qualification of the Air Cleaning Units for nuclear plant Ulchin 5 and 6 has been performed with the guideline of ASME Section III and IEEE 3444 code. By using the structural and geometrical similarity analysis, the three models to be analyzed are condensed into a single model and, at the same time, the excitation forces and other operating loads for each model are encompassed with respect to different loading conditions. As the fundamental frequencies of the structure are found to be less than 33Hz, which is the upper frequency limit of the seismic load, response spectrum analysis using ANSYS is performed in order to combine the modal stresses within the frequency limit. In order to confirm the structural and electric stability of the major components, modal analysis theory is adopted to derive the required response spectrum at the component locations. As the all combined stresses obtained from the above procedures are less than allowable stresses and no mechanical or electrical failures are found from the seismic testing, the authors confirm the safety of the nuclear equipments Air Cleaning Units studied in this paper

  8. Investigation of the emissions and profiles of a wide range of VOCs during the Clean air for London project

    Science.gov (United States)

    Holmes, Rachel; Lidster, Richard; Hamilton, Jacqueline; Lee, James; Hopkins, James; Whalley, Lisa; Lewis, Alistair

    2014-05-01

    The majority of the World's population live in polluted urbanized areas. Poor air quality is shortening life expectancy of people in the UK by an average 7-8 months and costs society around £20 billion per year.[1] Despite this, our understanding of atmospheric processing in urban environments and its effect on air quality is incomplete. Air quality models are used to predict how air quality changes given different concentrations of pollution precursors, such as volatile organic compounds (VOCs). The urban environment of megacities pose a unique challenge for air quality measurements and modelling, due to high population densities, pollution levels and complex infrastructure. For over 60 years the air quality in London has been monitored, however the existing measurements are limited to a small group of compounds. In order to fully understand the chemical and physical processes that occur in London, more intensive and comprehensive measurements should be made. The Clean air for London (ClearfLo) project was conducted to investigate the air quality, in particular the boundary layer pollution, of London. A relatively new technique, comprehensive two dimensional gas chromatography (GC×GC) [2] was combined with a well-established dual channel GC (DC-GC) [3] system to provide a more comprehensive measurement of VOCs. A total of 78 individual VOCs (36 aliphatics, 19 monoaromatics, 21 oxygenated and 2 halogenated) and 10 groups of VOCs (8 aliphatic, 1 monoaromatic and 1 monoterpene) from C1-C13+ were quantified. Seasonal and diurnal profiles of these VOCs have been found which show the influence of emission source and chemical processing. Including these extra VOCs should enhance the prediction capability of air quality models thus informing policy makers on how to potentially improve air quality in megacities. References 1. House of Commons Environmental Audit Committee, Air Quality: A follow-up report, Ninth Report of session 2012-12. 2. Lidster, R.T., J.F. Hamilton

  9. OH and HO2 chemistry in clean marine air during SOAPEX-2

    Directory of Open Access Journals (Sweden)

    R. Sommariva

    2004-01-01

    Full Text Available Model-measurement comparisons of HOx in extremely clean air ([NO] The free-radical chemistry was studied using a zero-dimensional box-model based upon the Master Chemical Mechanism (MCM. Two versions of the model were used, with different levels of chemical complexity, to explore the role of hydrocarbons upon free-radical budgets under very clean conditions. The "detailed" model was constrained to measurements of CO, CH4 and 17 NMHCs, while the "simple" model contained only the CO and CH4 oxidation mechanisms, together with inorganic chemistry. The OH and HO2 (HOx concentrations predicted by the two models agreed to within 5–10%. The model results were compared with the HOx concentrations measured by the FAGE (Fluorescence Assay by Gas Expansion technique during four days of clean Southern Ocean marine boundary layer (MBL air. The models overestimated OH concentrations by about 10% on two days and about 20% on the other two days. HO2 concentrations were measured during two of these days and the models overestimated the measured concentrations by about 40%. Better agreement with measured HO2 was observed by using data from several MBL aerosol measurements to estimate the aerosol surface area and by increasing the HO2 uptake coefficient to unity. This reduced the modelled HO2 overestimate by ~40%, with little effect on OH, because of the poor HO2 to OH conversion at the low ambient NOx concentrations. Local sensitivity analysis and Morris One-At-A-Time analysis were performed on the "simple" model, and showed the importance of reliable measurements of j(O1D and [HCHO] and of the kinetic parameters that determine the efficiency of O(1D to OH and HCHO to HO2 conversion. A 2σ standard deviation of 30–40% for OH and 25–30% for HO2 was estimated for the model calculations using a Monte Carlo technique coupled with Latin Hypercube Sampling (LHS.

  10. 76 FR 16646 - Circadian, Inc., Clean Energy Combustion, Inc. (n/k/a Clean Energy Combustion Systems, Inc...

    Science.gov (United States)

    2011-03-24

    ... From the Federal Register Online via the Government Publishing Office SECURITIES AND EXCHANGE COMMISSION Circadian, Inc., Clean Energy Combustion, Inc. (n/k/a Clean Energy Combustion Systems, Inc.), Collectible Concepts Group, Inc., Communitronics of America, Inc. (n/k/a RPM Advantage, Inc.), and ConSyGen, Inc., Order of Suspension of...

  11. Mobile GAC system cleans up petroleum leak

    International Nuclear Information System (INIS)

    Industry experts have been aware of carbon technology's environmental benefits for more than a decade. These benefits derive in part from granular activated carbon's (GAC) physical properties, including attrition resistance, high surface area, adsorption rate and capacity. Most often used to remove dissolved organics, industrial solvents and other toxic chemicals from groundwater, wastewater and potable sources, GAC expedites EPA compliance and is ideal for a wide variety of remediation applications. Secondary benefits of GAC systems include decolorization, odor control and solvent recovery. Now, pressure-rated systems are available to improve remediation efficiency and speed compliance. Using high-quality GAC, these systems adsorb groundwater contaminants to less-than-detectable concentrations with minimum downtime. This paper reports on a hydrogeological study conducted to investigate the extent of contamination and make recommendations on the best technology available to begin remediating the site. Forty-five monitoring wells were installed to identify the plume's vertical and horizontal profiles, direction of flow and groundwater characteristics. Results were used to identify ideal locations for placing the purge wells necessary to begin remediation

  12. ENVIRONMENTAL TECHNOLOGY VERIFICATION, TEST REPORT OF MOBILE SOURCE EMISSIONS CONTROL DEVICES/CLEAN DIESEL TECHNOLOGIES FUEL BORNE CATALYST WITH CLEANAIR SYSTEM'S DIESEL OXIDATION CATALYST

    Science.gov (United States)

    The Environmental Technology Verification report discusses the technology and performance of the Fuel-Borne Catalyst with CleanAir System's Diesel Oxidation Catalyst manufactured by Clean Diesel Technologies, Inc. The technology is a fuel-borne catalyst used in ultra low sulfur d...

  13. Criminal law in the system of legal instruments under environmental law. Shown by examples of German and U.S. American clean air policy; Das Strafrecht im System umweltrechtlicher Instrumentarien. Am Beispiel deutscher und US-amerikanischer Luftreinhaltepolitik

    Energy Technology Data Exchange (ETDEWEB)

    Rohr, B.M. von

    1995-12-31

    The authoress presents an analysis of the entire range of governmental instruments and measures and their systematic interlacement, as available under the German or the U.S. American law for protection of the environment. This analysis is the basis for the subsequent study aiming at clarifying the legitimacy and the required design of laws and regulations defining crimes and sanctions or penalties in the system of environmental law. The authoress derives a characterisation of legislative intent and mode of application of environmental criminal law which differs from that of the ``classic`` criminal law. Pursuing from this characterisation of legal instruments and methods, and from the framework of governmental action and related alternatives available under U.S. legislation, the authoress explains a number of appoaches recommended for reform and amendment of the current German system of environmental criminal law, which hitherto has shown low efficiency. (orig.) [Deutsch] Die Autorin nimmt eine Analyse der Gesamtheit staatlicher Massnahmen und ihrer systematischen Beziehungen im deutschen und US-amerikanischen Umweltrecht vor. Diese Analyse bildet die Grundlage der zentralen Frage der Untersuchung nach der Legitimitaet und notwendigen Struktur umweltstrafrechtlicher Normen. Dabei kommt die Autorin zu einer vom klassischen Kernstrafrecht abweichenden Funktionsbestimmung des Umweltstrafrechts. Ausgehend von dieser Positionsbestimmung des Strafrechts und den in den USA vorgefundenen Handlungsalternativen entwickelt die Autorin eine Reihe von Reformvorschlaegen als Antwort auf die derzeitige Ineffizienz der des deutschen Umweltstrafrechts. (orig.)

  14. Evaluation Clean Air Effects on Tehran City Residential Houses Price in 2009

    Directory of Open Access Journals (Sweden)

    Aghapour Sabbagi M.

    2011-06-01

    Full Text Available BackgroundsandObjectives: Environmental activitiesunknownprice and value caused establishing of some unique characteristics for mentioned commodities. One of these characteristics was existing gap between private and social cost and benefit. For assessing these activities different approaches include travel cost, willingness to pay and hedonic price had been suggested. According to Tehran's air pollution problem, in this study Hedonic approach had was used for the assessment of healthy air on Tehran's residential house price.Materials and Method : Hedonic approach is one of the methods that are used for evolution environmental goods. In this method, each good's price is estimated as a functions of that good`s properties. To gather this study information 300 questionnaires has been collected by random sampling from different area of Tehran.Result: Results revealed that activities in order to reduce air pollutions, in addition to environmental value have economical value form the point of view of consumers. Also, results show that willingness to pay of every Tehran's citizens for every square meter of house located in region with less pollution is between 1120 to 1350 thousands Rials.Conclusion: According to the obtained results can be said that, clean air as an environmental good from the viewpoint of consumers has economic value that can be calculated this value using methods such as Hedonic.

  15. Trend analysis air pollution. The effects of the working programme 'Clean and Efficient' on the emission of air pollutants

    International Nuclear Information System (INIS)

    This report explores the effects of the Dutch Climate Programme 'Clean and Efficient - Opportunities for Tomorrow' on the emissions of air pollutants, as included in the National Emissions Ceilings. The starting point for the analysis is the ex ante evaluation of Clean and Efficient as published in September 2007. On the national level, the relative effects on air pollutant emissions are invariably much smaller than those on domestic greenhouse gas emissions. With a 1% decrease in domestic greenhouse emissions, SO2 emission decrease between 0.3 and 0.5%, NOx emissions between 0.1 and 0.2%, NMVOC emissions decrease about 0.02 % and PM10 emissions decrease about 0.1%. Some general causes explain the differences between the effects on GHG emissions and NEC-emissions. Only part of both the NEC-emissions and the GHG-emissions is linked to energy use. Further, replacement of fossil fuels by biomass results in lower fossil CO2 emissions, but NEC-emissions remain roughly the same. Finally, emission factors of NEC-emissions vary strongly with energy carriers and processes, and reduction of energy use is unevenly divided among energy carriers and processes. Specifically for the Netherlands, the role of electricity exports is important. Strong climate policies and high CO2 prices are likely to result in lower electricity demand, more renewable electricity generation and more cogeneration. However, they are likely to improve the international competitiveness of the Dutch electricity generation as well. As a result, electricity exports rise and part of the emission reductions materialize outside the Netherlands, rather than within its borders. In the case of GHG-emissions, burden sharing mechanisms and trade in emission right make sure that this is not a real problem. As comparable mechanisms for NEC-emissions do not exist, the GHG burden sharing and emission trading pose a risk for the attainment of Dutch NEC-targets

  16. A Framework for Modular Modeling of the Diesel Engine Exhaust Gas Cleaning System

    DEFF Research Database (Denmark)

    Åberg, Andreas; Hansen, Thomas Klint; Linde, Kasper;

    2015-01-01

    Pollutants from diesel engines have a negative effect on urban air quality. Because of this and new legislation restricting the emission level, it is necessary to develop exhaust gas treatment systems for diesel engines that can reduce the amount of pollutants. A modular model capable of simulating...... modular model. Four different models in the automotive diesel exhaust gas cleaning system are presented briefly. Based on the presented methodology, it is discussed which changes are needed to the models to create a modular model of the whole catalytic system....

  17. Chemical Cleaning Process for Porable Water Distrubution Pipe Systems

    OpenAIRE

    ECT Team, Purdue

    2007-01-01

    Aging potable water distribution pipe systems are becoming a major concern throughout the world. Deterioration of water quality and service as a result of micro biological tuberculation and corrosion continues to increase. Major costs for replacement or rehabilitation of distribution systems are being faced by most communities. The chemical cleaning solution is an organic oxide scavenger which is mixed with a predetermined quantity of muriatic acid and circulated through an isolated section o...

  18. Boost matrix converters in clean energy systems

    Science.gov (United States)

    Karaman, Ekrem

    This dissertation describes an investigation of novel power electronic converters, based on the ultra-sparse matrix topology and characterized by the minimum number of semiconductor switches. The Z-source, Quasi Z-source, Series Z-source and Switched-inductor Z-source networks were originally proposed for boosting the output voltage of power electronic inverters. These ideas were extended here on three-phase to three-phase and three-phase to single-phase indirect matrix converters. For the three-phase to three-phase matrix converters, the Z-source networks are placed between the three-switch input rectifier stage and the output six-switch inverter stage. A brief shoot-through state produces the voltage boost. An optimal pulse width modulation technique was developed to achieve high boosting capability and minimum switching losses in the converter. For the three-phase to single-phase matrix converters, those networks are placed similarly. For control purposes, a new modulation technique has been developed. As an example application, the proposed converters constitute a viable alternative to the existing solutions in residential wind-energy systems, where a low-voltage variable-speed generator feeds power to the higher-voltage fixed-frequency grid. Comprehensive analytical derivations and simulation results were carried out to investigate the operation of the proposed converters. Performance of the proposed converters was then compared between each other as well as with conventional converters. The operation of the converters was experimentally validated using a laboratory prototype.

  19. Setting of technical rules by the Clean Air Commission (KRdL) of VDI and DIN in the sector of measuring techniques - a glance backward and outlook

    International Nuclear Information System (INIS)

    The precursors of the Clean Air Commission were the VDI expert groups on particulates (1928-1972) and clean air (1957-1990) as well as the DIN norms commitee (NLuft - 1971-1990), whose activities are briefly described. But since 1990, it is the Clean Air Commission (''Kommission Reinhaltung der Luft -KRdL'') that takes care of the harmonization of technical rules, also with a view to the realization of the internal European market. (DG)

  20. Influence of gasification on the performance of a 1 MHz nozzle system in megasonic cleaning

    NARCIS (Netherlands)

    Hauptmann, M.; Brems, S.; Camerotto, E.; Zijlstra, A.; Doumen, G.; Bearda, T.; Mertens, P.W.; Lauriks, W.

    2010-01-01

    Single-wafer cleaning based on megasonic nozzle systems can be used for removing nano-particles. An optimized cleaning process must deliver a high degree of cleaning uniformity with a minimal amount of structural damage. However, the cleaning liquid is confined to a sonicated liquid jet, which is ej

  1. OH and HO2 chemistry in clean marine air during SOAPEX-2

    Science.gov (United States)

    Sommariva, R.; Haggerstone, A.-L.; Carpenter, L. J.; Carslaw, N.; Creasey, D. J.; Heard, D. E.; Lee, J. D.; Lewis, A. C.; Pilling, M. J.; Zádor, J.

    2004-06-01

    Model-measurement comparisons of HOx in extremely clean air ([NO]Measurements were made during the second Southern Ocean Photochemistry Experiment (SOAPEX-2), held in austral summer 1999 at the Cape Grim Baseline Air Pollution Station in north-western Tasmania, Australia. The free-radical chemistry was studied using a zero-dimensional box-model based upon the Master Chemical Mechanism (MCM). Two versions of the model were used, with different levels of chemical complexity, to explore the role of hydrocarbons upon free-radical budgets under very clean conditions. The "detailed" model was constrained to measurements of CO, CH4 and 17 NMHCs, while the "simple" model contained only the CO and CH4 oxidation mechanisms, together with inorganic chemistry. The OH and HO2 (HOx) concentrations predicted by the two models agreed to within 5-10%. The model results were compared with the HOx concentrations measured by the FAGE (Fluorescence Assay by Gas Expansion) technique during four days of clean Southern Ocean marine boundary layer (MBL) air. The models overestimated OH concentrations by about 10% on two days and about 20% on the other two days. HO2 concentrations were measured during two of these days and the models overestimated the measured concentrations by about 40%. Better agreement with measured HO2 was observed by using data from several MBL aerosol measurements to estimate the aerosol surface area and by increasing the HO2 uptake coefficient to unity. This reduced the modelled HO2 overestimate by ~40%, with little effect on OH, because of the poor HO2 to OH conversion at the low ambient NOx concentrations. Local sensitivity analysis and Morris One-At-A-Time analysis were performed on the "simple" model, and showed the importance of reliable measurements of j(O1D) and [HCHO] and of the kinetic parameters that determine the efficiency of O(1D) to OH and HCHO to HO2 conversion. A 2σ standard deviation of 30-40% for OH and 25-30% for HO2 was estimated for the model

  2. OH and HO2 chemistry in clean marine air during SOAPEX-2

    Directory of Open Access Journals (Sweden)

    A. C. Lewis

    2004-01-01

    Full Text Available Model-measurement comparisons of HOx in extremely clean air ([NO]<3  ppt are reported. Measurements were made during the second Southern Ocean Photochemistry Experiment (SOAPEX-2, held in austral summer 1999 at the Cape Grim Baseline Air Pollution Station in north-western Tasmania, Australia. The free-radical chemistry was studied using a zero-dimensional box-model based upon the Master Chemical Mechanism (MCM. Two versions of the model were used, with different levels of chemical complexity, to explore the role of hydrocarbons upon free-radical budgets under very clean conditions. The "detailed" model was constrained to measurements of CO, CH4 and 15 NMHCs, while the "simple" model contained only the CO and  CH4 oxidation mechanisms, together with inorganic chemistry. The OH and HO2 (HOx concentrations predicted by the two models agreed to within 5–10%. The model results were compared with the HOx concentrations measured by the FAGE (Fluorescence Assay by Gas Expansion technique during four days of clean Southern Ocean marine boundary layer (MBL air. The models overestimated OH concentrations by about 10% on two days and about 20% on the other two days. HO2 concentrations were measured during two of these days and the models overestimated the measured concentrations by about 40%. Better agreement with measured HO2 was observed by using data from several MBL aerosol measurements to estimate the aerosol surface area and by increasing the HO2 uptake coefficient to unity. This reduced the modelled HO2 overestimate by ~40%, with little effect on OH, because of the poor HO2 to OH conversion at the low ambient NOx concentrations. Local sensitivity analysis and Morris One-At-A-Time analysis were performed on the "simple" model, and showed the importance of reliable measurements of j(O1D and [HCHO] and of the kinetic parameters that determine the efficiency of  O(1D to OH and HCHO to HO2 conversion. A 2σ standard deviation of 30–40% for OH and

  3. Fuelling clean air : municipal fuel purchasing policies that reduce emissions contributing to poor air quality and climate change

    International Nuclear Information System (INIS)

    Air quality can be improved by low sulphur fuels in two ways: through the direct reduction of sulphates, sulphur dioxide and PM; and by improving the effectiveness of existing emission control devices. This report examined three case studies involving the fuel purchasing policies in three Ontario municipalities: Toronto, Waterloo, and Brampton. Toronto favors purchasing conventional fuels with lower sulphur levels. Waterloo will purchase on-road diesel for its off-road diesel fleet; ultra low sulphur diesel (ULSD) for buses; and 10 per cent ethanol blended with 90 per cent gasoline (E10) for its gasoline-fuelled fleet. Brampton purchased 20 per cent biodiesel blended with 80 per cent on-road diesel (B20). Two approaches were examined for lowering emissions from gasoline fuelled vehicles: favouring gasoline with the lowest sulphur levels, and purchasing E10. It was recommended that the Greater Toronto Area (GTA) Clean Air Council look into: ownership of emissions trading credits created as a result of fuel purchasing policies; the benefits of, and mechanisms available for, pooling fuel purchases; and, establishing a subcommittee to monitor developments related to fuels, vehicles and emission control technologies. 48 refs., 18 tabs

  4. Air cooling system

    International Nuclear Information System (INIS)

    A procedure for cooling the steam from a turbine used in conjunction with a power nuclear reactor has been described in the main patent. According to said procedure, use is made of a circuit where a two-phase mixture is circulated, said closed circuit connecting the turbine condenser to a cooling tower. According to the present addition patent, the cooling structure is provided with cooling fins previously hollowed in view of increasing the interface between the fluid and said structure, which improves the performance of the system

  5. The effects of Title IV of the Clean Air Act amendments of 1990 on electric utilities: An update

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    This report presents data and analyses related to Phase I implementation of the Clean Air Act Amendment by electric utilities. It describes the strategies used to comply with the Acid Rain Program in 1995, the effect of compliance on sulfur dioxide emissions levels, the cost of compliance, and the effects of the program on coal supply and demand. The first year of Phase I demonstrated that the market-based sulfur dioxide emissions control system could achieve significant reductions in emissions at lower than expected costs. Some utilities reduced aggregate emissions below legal requirements due to economic incentives; other utilities purchased additional allowances to avoid noncompliance. More than half of the utilities switched to or blended with lower sulfur coal, due to price reductions in the coal market which were partially due to the allowance trading program. 21 figs., 20 tabs.

  6. Economic Aspects of Air and Gas Cleaning for Nuclear Energy Processes

    International Nuclear Information System (INIS)

    In this paper the basic requirements for control of gaseous and particulate effluents are given as applied to problems of feed material production, isotope separation, fuel element fabrication, fuel recovery and reactor operation. There are also instances where non-radioactive nuclear materials with toxic or nuisance effluents such as from beryllium and zirconium production are of concern and these too must be controlled at reasonable costs. The factors involved in capital and operating costs of gas cleaning equipment and the types of applications in the United States are described in some detail. Gaseous effluent problems have, of course, been attacked and controlled by several types of device but their performance has been measured on a comparable basis. It is thus possible to judge operating characteristics on an economic basis as related to power consumption, adsorbent costs, space charges, corrosion problems and other operational factors. The United States Atomic Energy Commission through its contract with the Harvard University Air Cleaning Laboratory has initiated an evaluation program with cooperation, from the various facilities and contractors to the Commission. In this study the basic factors necessary to obtain quantitative cost delineation and evaluation have been outlined and some preliminary findings will be presented. The paper also presents a review of other economic studies made in the United States on particular process or facility applications. (author)

  7. The benefits of whole-house in-duct air cleaning in reducing exposures to fine particulate matter of outdoor origin: a modeling analysis.

    Science.gov (United States)

    Macintosh, David L; Minegishi, Taeko; Kaufman, Matthew; Baker, Brian J; Allen, Joseph G; Levy, Jonathan I; Myatt, Theodore A

    2010-03-01

    Health risks of fine particle air pollution (PM(2.5)) are an important public health concern that has the potential to be mitigated in part by interventions such as air cleaning devices that reduce personal exposure to ambient PM(2.5). To characterize exposure to ambient PM(2.5) indoors as a function of residential air cleaners, a multi-zone indoor air quality model was used to integrate spatially resolved data on housing, meteorology, and ambient PM(2.5), with performance testing of residential air cleaners to estimate short-term and annual average PM(2.5) of outdoor origin inside residences of three metropolitan areas. The associated public health impacts of reduced ambient PM(2.5) exposure were estimated using a standard health impact assessment methodology. Estimated indoor levels of ambient PM(2.5) varied substantially among ventilation and air cleaning configurations. The median 24-h average indoor-outdoor ratio of ambient PM(2.5) was 0.57 for homes with natural ventilation, 0.35 for homes with central air conditioning (AC) with conventional filtration, and 0.1 for homes with central AC with high efficiency in-duct air cleaner. Median modeled 24-h average indoor concentrations of PM(2.5) of outdoor origin for those three configurations were 8.4, 5.3, and 1.5 microg/m(3), respectively. The potential public health benefits of reduced exposure to ambient PM(2.5) afforded by air cleaning systems were substantial. If the entire population of single-family homes with central AC in the modeling domain converted from conventional filtration to high-efficiency in-duct air cleaning, the change in ambient PM(2.5) exposure is estimated to result in an annual reduction of 700 premature deaths, 940 hospital and emergency room visits, and 130,000 asthma attacks in these metropolitan areas. In addition to controlling emissions from sources, high-efficiency whole-house air cleaner are expected to reduce exposure to particles of outdoor origin and are projected to be an

  8. Prizes awarded in fiscal 1999 by the Minister for International Trade and Industry on factories having applied excellent energy management. Energy conservation by installing fuel cell power generation facilities utilizing methane gas generated from waste water treatment plants / Improvements toward a clean room and energy saving air conditioning system; 1999 nendo energy kanri yuryo kojo tsusho sangyo daijin hyosho jusho. 1999 nendo shigen energy sho chokan hyosho jusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-04-01

    In order to achieve energy conservation in a waste water treatment plant in a brewery factories, an anaerobic treatment facility was introduced, and a fuel cell power generation facility effectively utilizing methane gas generated from the anaerobic waste water treatment plant was installed. This has resulted in large reduction in the operating number of blowers in the waste water treatment facility of activated sludge system. In addition, electric power, steam, and hot water generated from the fuel cells are effectively utilized as the factory utility. In energy conservation in an optical communication device manufacturing factory, the fan filter unit system was adopted, having been changed from the circulation air conditioner, a conventional type air conditioning system. The present system is a circulation system integrating the fan with the filter, making it possible to circulate air in the room to perform control of temperature, humidity, and dust in a clean room. Thus, the system has eliminated the circulating air conditioner, and reduced the air conditioner capacity by 42% and power consumption by 58.6% compared with those in the conventional circulation system. (NEDO)

  9. ECOLOGICAL CLEANING SYSTEMS FOR OLD ICONS PAINTED IN TEMPERA

    OpenAIRE

    Silvea Pruteanu; Petronela Spiridon; Viorica Vasilache; Ion Sandu

    2014-01-01

    Old icons, especially those involved in liturgical rituals are affected in time by external agents factors (temperature, humidity, light, pollution, microbiological attack, abrasion etc.), resulting changes of the appearance and of the structural integrity, dirt deposits, altered varnish and painting layer, cracks, material loss etc. In order to remove the dirt deposits, there are used cleaning systems with dry wiping, vacuuming, scraping, washing with organic solvents, ion exchange solutions...

  10. ECOLOGICAL CLEANING SYSTEMS FOR OLD ICONS PAINTED IN TEMPERA

    Directory of Open Access Journals (Sweden)

    Silvea Pruteanu

    2014-12-01

    Full Text Available Old icons, especially those involved in liturgical rituals are affected in time by external agents factors (temperature, humidity, light, pollution, microbiological attack, abrasion etc., resulting changes of the appearance and of the structural integrity, dirt deposits, altered varnish and painting layer, cracks, material loss etc. In order to remove the dirt deposits, there are used cleaning systems with dry wiping, vacuuming, scraping, washing with organic solvents, ion exchange solutions, polyelectrolytes, surfactants, and so on, by enzymatic systems or by laser pyrolysis. The last two processes being considered aggressive and highly invasive, although they do clean very well adherent dirt deposits, which strongly degraded the varnish to total blackening (the iconographic image cannot be seen. Based on the literature in the field, regarding the nature of the materials used during the painting process and of the types and structures of the deposits, a series of alcoholic solutions of different concentrations were made, as such or basified, which were compared with ecologic synergic systems based on organic uncolored vegetable juices and decoctions from dried plants. The cleaning effectiveness was done by visual analysis and CIE L*a*b* reflection colorimetry, space proposed by the CIE (International Commission on Illumination in 1976, was used. This technique permitting to determine by color deviations the critical point where the patina and polychromes layer.

  11. Self Cleaning High Efficiency Particulate Air (HEPA) Filtration without Interrupting Process Flow - 59347

    International Nuclear Information System (INIS)

    The strategy of protecting the traditional glass fibre HEPA filtration train from it's blinding contamination and the recovery of dust by the means of self cleaning, pre-filtration is a proven means in the reduction of ultimate disposal volumes and has been used within the Fuel Production Industry. However, there is an increasing demand in nuclear applications requiring elevated operating temperatures, fire resistance, moisture resistance and chemical composition that the existing glass fibre HEPA filtration cannot accommodate, which can be remedied by the use of a metallic HEPA filter media. Previous research suggests that the then costs to the Department of Energy (DOE), based on a five year life cycle, was $29.5 million for the installation, testing, removal and disposal of glass fibre HEPA filtration trains. Within these costs, $300 was the value given to the filter and $4, 450 was given to the peripheral activity. Development of a low cost, cleanable, metallic, direct replacement of the traditional filter train will the clear solution. The Bergman et al work has suggested that a 1000 ft3/min, cleanable, stainless HEPA could be commercially available for $5, 000 each, whereas the industry has determined that the truer cost of such an item in isolation would be closer to $15, 000. This results in a conflict within the requirement between 'low cost' and 'stainless HEPA'. By proposing a system that combines metallic HEPA filtration with the ability to self clean without interrupting the process flow, the need for a tradition HEPA filtration train will be eliminated and this dramatically reduces the resources required for cleaning or disposal, thus presenting a route to reducing ultimate costs. The paper will examine the performance characteristics, filtration efficiency, flow verses differential pressure and cleanability of a self cleaning HEPA grade sintered metal filter element, together with data to prove the contention. (authors)

  12. Influence of sonication conditions on the efficiency of ultrasonic cleaning with flowing micrometer-sized air bubbles.

    Science.gov (United States)

    Tuziuti, Toru

    2016-03-01

    This paper describes the sizes of cleaned areas under different sonication conditions with the addition of flowing micrometer-sized air bubbles. The differences in the cleaned area of a glass plate pasted with silicon grease as a dirty material under different sonication conditions were investigated after tiny bubbles were blown on the dirty plate placed in an underwater sound field. The ultrasound was applied perpendicular to the bubble flow direction. The shape of the cleaned areas was nearly elliptical, so the lengths of the minor and major axes were measured. The length of the minor axis under sweep conditions (amplitude modulation), for which the average power was lower than that for continuous wave (CW) irradiation, was comparable to that for CW irradiation and was slightly larger than under bubble flow only. Not only the relatively high power for CW irradiation, but also the larger angular change of the bubble flow direction under sweep conditions contributed to the enlargement of the cleaned area in the direction of the minor axis. The combination of bubble flow and sonication under sweep or CW conditions produced a larger cleaned area compared with bubble flow only, although the increase was not higher than 20%. A rapid change from an air to water interface caused by the bubble flow and water jets caused by the collapse of bubbles due to violent pulsation is the main cleaning mechanism under a combination of ultrasound and bubble flow. PMID:26422770

  13. 40 CFR 62.14820 - How must I monitor opacity for air curtain incinerators that burn 100 percent wood wastes, clean...

    Science.gov (United States)

    2010-07-01

    ... wood wastes, clean lumber, and/or yard waste? (a) Use Method 9 of 40 CFR part 60, Appendix A to... curtain incinerators that burn 100 percent wood wastes, clean lumber, and/or yard waste? 62.14820 Section... Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber...

  14. CACD (Complex Air Cleaning Devices) of the GTE (Gas turbine electrostation)-110: Problems and solutions

    Science.gov (United States)

    Budakov, I. V.; Neuimin, V. M.

    2015-12-01

    The paper considers CACD of the compressor of the GTE-110 gas turbine. The CACD efficiency has been tested under different conditions of the GTE-325 of the Ivanovo combined cycle plant (CCP) JSC INTER RAO-Electrogeneration Exploitation. It sets out the requirements for the dust collector, de-icing system, and air intake tract CACD. De-icing and air preparation methods are shown.

  15. Experimental evaluation on energy performance of innovative clean air heat pump for indoor environment control in summer and winter seasons

    DEFF Research Database (Denmark)

    Nie, Jinzhe; Fang, Lei; Olesen, Bjarne W.

    2014-01-01

    was developed. Laboratory experimental studies were conducted to investigate its energy performance under different outdoor climates including cold, mild-cold, mild-hot and extremely hot and humid climates. The energy performance of the CAHP was then evaluated by comparing with a conventional air source heat......Based on the air purification capacity of regenerative silica gel rotor, an innovative clean air heat pump (CAHP) was designed, developed and investigated through experimental studies. The CAHP integrated air purification, dehumidification and heating/cooling in one unit. A prototype of the CAHP...... pump. The results showed that to keep same indoor air quality, the CAHP could save substantial amount of energy. For example, compared to the conventional air source heat pump, the CAHP could save up to 59%, 40%, 30% of electricity for ventilation and air conditioning in a test room in summer...

  16. Reactive inspection response of NRC Region III to potential technical deficiencies identified in recent Nuclear Air Cleaning Conference papers

    International Nuclear Information System (INIS)

    In order to effectively meet its responsibility to protect the public health and safety, the Nuclear Regulatory Commission (NRC) nuclear power plant licensing and inspection programs respond to potential technical deficiencies identified by conference and professional society meeting papers when deemed appropriate. The NRC staff's response mechanisms for such technical deficiencies include: generic letters, Bulletins, Information Notices, Standard Review Plan (NUREG-0800) revisions, docketed Final Safety Analysis Report (FSAR) questions, special studies, special (reactive) inspection, and inspection program revisions. This paper describes reactive inspection efforts by Region III in response to potential technical deficiencies identified in recent air cleaning conference papers, including: post-accident effluent sample line deposition losses; failure to implement good engineering practices in the design, construction, and testing of Nuclear Air Treatment Systems (NATS); filter bypass via filter housing drain lines; spinster carbon degradation; use of silicone sealants and other temporary patching material in NATS; filter housing fire protection deluge system problems; lack of charcoal batch traceability; Quality Assurance records problems involving equipment, vendor, filter, and personnel qualifications; inadequate ANSI/ASME N510 acceptance criteria and tests; and failure to adequately demonstrate control room habitability per 10 CFR 50, Appendix A, General Design Criterion-19. Region III inspections indicate that many of these deficiencies appear to be prevalent. Inspection findings and utility responses to the findings are discussed. NRC Region III and Headquarters programmatic reactions to the identified generic problem areas are also discussed

  17. Pollution prevention incentives and disincentives created by the Clean Air Act

    International Nuclear Information System (INIS)

    Environmental laws and regulations have not always been implemented in a manner that allows for the consideration of pollution prevention (P2) alternatives as a means of achieving progress toward air quality goals. Recently, the US Environmental Protection Agency (EPA) has been making strides to reinterpret laws and regulations to be more flexible and encourage P2 projects that do not involve end-of-the-pipe controls. For instance, when conducting control technology evaluations such as best available control technology (BACT) and lowest achievable emission rate (LAER), facilities can and should take into consideration P2 options that accomplish the same emission reduction goals as traditional end-of-the-pipe controls. There are also new emissions trading provisions building on those allowed in the acid rain and offset trading programs that promise to make P2 projects much more cost-effective. Several traditional 'command-and-control' programs of the Clean Air Act (CAA) also promote P2 projects. For instance, emission reductions realized through P2 projects show managers a direct cost savings due to reductions in Title V facility annual emissions fees and possibly a direct cost benefit through sale of emission credits. Furthermore, the CAA encourages P2 indirectly through the detail understanding of processes gained from emissions inventories and risk management plans (RMPs). However, many CAA prescriptive programs create disincentives for industry to select P2 alternatives. 30 refs

  18. Clean Lead Facility Inventory System user`s manual

    Energy Technology Data Exchange (ETDEWEB)

    Garcia, J.F.

    1994-12-01

    The purpose of this user`s manual is to provide instruction and guidance needed to enter and maintain inventory information for the Clean Lead Facility (CLF), PER-612. Individuals responsible for maintaining and using the system should study and understand the information provided. The user`s manual describes how to properly use and maintain the CLF Inventory System. Annual, quarterly, monthly, and current inventory reports may be printed from the Inventory System for reporting purposes. Profile reports of each shipment of lead may also be printed for verification and documentation of lead transactions. The CLF Inventory System was designed on Microsoft Access version 2.0. Similar inventory systems are in use at the Idaho National Engineering Laboratory (INEL) to facilitate site-wide compilations of mixed waste data. The CLF Inventory System was designed for inventorying the clean or non-radioactive contaminated lead stored at the CLF. This data, along with the mixed waste data, will be compiled into the Idaho Mixed Waste Information (IMWI) system for reporting to the Department of Energy Idaho Office, Department of Energy Headquarters, and/or the State of Idaho.

  19. 75 FR 75463 - Clean Air Act Operating Permit Program; Petition To Object to Title V Permit for Luke Paper...

    Science.gov (United States)

    2010-12-03

    ... From the Federal Register Online via the Government Publishing Office ENVIROMENTAL PROTECTION AGENCY Clean Air Act Operating Permit Program; Petition To Object to Title V Permit for Luke Paper... issues during the comment period or that the grounds for objection or other issue arose after the...

  20. 75 FR 22400 - Clean Air Act Operating Permit Program; Petition To Object to Title V Permit for Wheelabrator...

    Science.gov (United States)

    2010-04-28

    ... From the Federal Register Online via the Government Publishing Office ENVIROMENTAL PROTECTION AGENCY Clean Air Act Operating Permit Program; Petition To Object to Title V Permit for Wheelabrator... period or that the grounds for objection or other issue arose after the comment period. EPA received...

  1. 76 FR 4662 - Partial Grant of Clean Air Act Waiver Application Submitted by Growth Energy To Increase the...

    Science.gov (United States)

    2011-01-26

    ... AGENCY Partial Grant of Clean Air Act Waiver Application Submitted by Growth Energy To Increase the... Allowable Ethanol Content of Gasoline to 15 Percent; Decision of the Administrator. See 75 FR 68094.... All of the conditions are discussed in Section X of the October Waiver Decision (see 75 FR...

  2. 75 FR 68093 - Partial Grant and Partial Denial of Clean Air Act Waiver Application Submitted by Growth Energy...

    Science.gov (United States)

    2010-11-04

    ...The Environmental Protection Agency (EPA) is partially granting Growth Energy's waiver request application submitted under section 211(f)(4) of the Clean Air Act. This partial waiver allows fuel and fuel additive manufacturers to introduce into commerce gasoline that contains greater than 10 volume percent ethanol and no more than 15 volume percent ethanol (E15) for use in certain motor......

  3. Diffusion welding in air. [solid state welding of butt joint by fusion welding, surface cleaning, and heating

    Science.gov (United States)

    Moore, T. J.; Holko, K. H. (Inventor)

    1974-01-01

    Solid state welding a butt joint by fusion welding the peripheral surfaces to form a seal is described along with, autogenetically cleaning the faying or mating surfaces of the joint by heating the abutting surfaces to 1,200 C and heating to the diffusion welding temperature in air.

  4. Spatio-temporal cleaning of a femtosecond laser pulse through interaction with counter-propagating filaments in air

    OpenAIRE

    Jarnac, Amélie; Durand, Magali; Houard, Aurélien; Liu, Yi; Prade, Bernard; Richardson, Martin; Mysyrowicz, André

    2014-01-01

    We demonstrate spatiotemporal cleaning of a femtosecond laser pulse impinging on two counterpropagating filaments in air. The retroreflected signal essentially has a perfect beam profile. Prepulses present in the incident pulse are also efficiently removed. The performance of the “filament mirror” is explained by a plasma-mediated wave mixing process that can be viewed as a transient three-dimensional hologram.

  5. 76 FR 53452 - Clean Air Act Operating Permit Program; Response to Petition To Reopen the 2001 Title V Permit...

    Science.gov (United States)

    2011-08-26

    ... AGENCY Clean Air Act Operating Permit Program; Response to Petition To Reopen the 2001 Title V Permit for...: Environmental Protection Agency (EPA). ACTION: Notice of action denying petition to reopen Title V permit... 2001 Title V permit issued by the Pennsylvania Department of Environmental Protection (PADEP)...

  6. 23 CFR 633.211 - Implementation of the Clean Air Act and the Federal Water Pollution Control Act.

    Science.gov (United States)

    2010-04-01

    ... Pollution Control Act. Pursuant to regulations of the Environmental Protection Agency (40 CFR part 15) implementing requirements with respect to the Clean Air Act and the Federal Water Pollution Control Act are... Water Pollution Control Act. 633.211 Section 633.211 Highways FEDERAL HIGHWAY ADMINISTRATION,...

  7. 78 FR 45272 - Notice of Lodging of Proposed Third Amendment to Consent Decree Under the Clean Air Act

    Science.gov (United States)

    2013-07-26

    .... Lafarge North America et al, Civil Action No. 3:10-cv- 44. Following public notice and opportunity for... federal Clean Air Act, 42 U.S.C. 7401 et seq. by Lafarge North America, Lafarge Building Materials, and Lafarge Midwest (collectively, the ``Lafarge Companies'') alleged by Plaintiff United States and...

  8. 77 FR 38830 - Notice of Lodging of an Amendment to Consent Decree Under the Clean Air Act

    Science.gov (United States)

    2012-06-29

    ... June 25, 2012, a proposed Second Amendment to the consent decree in United States et al. v. Lafarge... and twelve states or state agencies against Lafarge North America, Inc., Lafarge Midwest, Inc., and Lafarge Building Materials, Inc. (``Lafarge'') for alleged violations of the Clean Air Act (``CAA''...

  9. Debris Removal Project K West Canister Cleaning System Performance Specification

    International Nuclear Information System (INIS)

    Approximately 2,300 metric tons Spent Nuclear Fuel (SNF) are currently stored within two water filled pools, the 105 K East (KE) fuel storage basin and the 105 K West (KW) fuel storage basin, at the U.S. Department of Energy, Richland Operations Office (RL). The SNF Project is responsible for operation of the K Basins and for the materials within them. A subproject to the SNF Project is the Debris Removal Subproject, which is responsible for removal of empty canisters and lids from the basins. Design criteria for a Canister Cleaning System to be installed in the KW Basin. This documents the requirements for design and installation of the system

  10. Debris Removal Project K West Canister Cleaning System Performance Specification

    Energy Technology Data Exchange (ETDEWEB)

    FARWICK, C.C.

    1999-12-09

    Approximately 2,300 metric tons Spent Nuclear Fuel (SNF) are currently stored within two water filled pools, the 105 K East (KE) fuel storage basin and the 105 K West (KW) fuel storage basin, at the U.S. Department of Energy, Richland Operations Office (RL). The SNF Project is responsible for operation of the K Basins and for the materials within them. A subproject to the SNF Project is the Debris Removal Subproject, which is responsible for removal of empty canisters and lids from the basins. Design criteria for a Canister Cleaning System to be installed in the KW Basin. This documents the requirements for design and installation of the system.

  11. Air filtration in HVAC systems

    CERN Document Server

    Ginestet, Alain; Tronville, Paolo; Hyttinen, Marko

    2010-01-01

    Air filtration Guidebook will help the designer and user to understand the background and criteria for air filtration, how to select air filters and avoid problems associated with hygienic and other conditions at operation of air filters. The selection of air filters is based on external conditions such as levels of existing pollutants, indoor air quality and energy efficiency requirements.

  12. Nonanalytic behavior of the spin susceptibility in clean Fermi systems

    International Nuclear Information System (INIS)

    The wave vector and temperature-dependent static spin susceptibility, χs(Q,T), of clean interacting Fermi systems is considered in dimensions 1≤d≤3. We show that at zero temperature χs is a nonanalytic function of |Q|, with the leading nonanalyticity being |Q|d-1 for 12ln|Q| for d=3. For the homogeneous spin susceptibility we find a nonanalytic temperature dependence Td-1 for 1s(Q=0) in d=3. copyright 1997 The American Physical Society

  13. Ventilation-air conditioning system

    International Nuclear Information System (INIS)

    Heretofore, in ventilation-air conditioning systems in a nuclear power plant, exhaust gases from each of the ventilation-air conditioning systems of a reactor building, a turbine building, a waste processing building are joined and they are released into atmosphere from the top of a high main exhaustion stack. In order to build such a high main exhaustion stack, a considerable construction cost is required and, in addition, there is a worry of lacking balance with surrounding scenery. Then, in the present invention, exhaust gases are heated by waste heat in a turbine during their introduction from the ventilation-air conditioning facility in the building of a power plant to the main exhaust stack. With such a constitution, since the exhaust gases are heated and their temperature is elevated, they uprise by natural convection when they are released from the top of the main exhaustion stack to the atmosphere. Accordingly, they are released to a level higher than the conventional case in view of the volume of the blower which sends the exhaust gases under pressure, to diffuse them to the atmosphere more sufficiently compared with a conventional case. Further, the height of the main exhaustion stack can be reduced, enabling to minimize the cost for moving the blower. (T.M.)

  14. Sulfur dioxide emissions and market effects under the Clean Air Act Acid Rain Program

    International Nuclear Information System (INIS)

    The Clean Air Act Amendments of 1990 (CAAA90) established a national program to control sulfur dioxide (SO2) emissions from electricity generation. CAAA90's market-based approach includes trading and banking of SO2-emissions allowances. The paper presents an analysis of data describing electric utility SO2 emissions in 1995, the first year of the program's Phase I, and market effects over the 1990-95 period. Fuel switching and flue-gas desulfurization were the dominant means used in 1995 by targeted generators to reduce emissions to 51% of 1990 levels. Flue-gas desulfurization costs, emissions allowance prices, low-sulfur coal prices, and average sulfur contents of coals shipped to electric utilities declined over the 1990-95 period. Projections indicate that 13-15 million allowances will have been banked during the programs' Phase I, which ends in 1999, a quantity expected to last through the first decade of the program's stricter Phase II controls. In 1995, both allowance prices and SO2 emissions were below pre-CAAA90 expectations. The reduction of SO2 emissions beyond pre-CAAA90 expectations, combined with lower-than-expected allowance prices and declining compliance costs, can be viewed as a success for market-based environmental controls. 21 refs., 6 figs., 3 tabs

  15. The off-gas cleaning system of the INER'S incinerator in Taiwan, Republic of China

    International Nuclear Information System (INIS)

    The incinerator designed and constructed by INER has been operated since 1976. It handles the radioactive wastes from INER and Taiwan Power Company. The dry off-gas cleaning system consists of two types of cyclones in series, two bag filters and two HEPA filters in parallel. One of each filter sets is provided as stand-by. The first cyclone is lined with refractory material and operated at 11000C to treat the high-temperature off-gas directly from the top of the incinerator. The off-gas of the first cyclone is mixed with ambient air for controlling the gas flow rate and reducing its temperature to about 2000C. After 10 years' operation, it is found that the radioactivity released in the gaseous effluent meets the MPC air requirement and the implementation of the refractory-lined cyclone extends the service lives of bag filter as well as HEPA filter

  16. Canister Cleaning System Final Design Report - Project A.2.A

    International Nuclear Information System (INIS)

    Approximately 2,300 metric tons Spent Nuclear Fuel (SNF) are currently stored within two water filled pools, the 105 K East (KE) fuel storage basin and the 105 K West (KW) fuel storage basin, at the U.S. Department of Energy, Richland Operations Office (RL). The SNF Project is responsible for operation of the K Basins and for the materials within them. A subproject to the SNF Project is the Debris Removal Subproject, which is responsible for removal of empty canisters and lids from the basins. The Canister Cleaning System (CCS) is part of the Debris Removal Project. The CCS will be installed in the KW Basin and operated during the fuel removal activity. The KW Basin has approximately 3600 canisters that require removal from the basin. The CCS is being designed to ''clean'' empty fuel canisters and lids and package them for disposal to the Environmental Restoration Disposal Facility complex. The system will interface with the KW Basin and be located in the Dummy Elevator Pit

  17. SAGE SOLVENT ALTERNATIVES GUIDE: SYSTEM IMPROVEMENTS FOR SELECTING INDUSTRIAL SURFACE CLEANING ALTERNATIVES

    Science.gov (United States)

    The paper describes computer software, called SAGE, that can provide not only cleaning recommendations but also general information on various surface cleaning options. In short, it is an advisory system which can provide users with vital information on the cleaning process optio...

  18. Human breath measurements in a clean-air chamber to determine half-lives for volatile organic compounds

    Science.gov (United States)

    Gordon, Sydney M.; Wallace, Lance A.; Pelllzzari, Edo D.; O'Neill, Hugh J.

    The expired breath of four non-occupationally exposed subjects was monitored following exposure at near-normal environmental concentrations using a specially developed pulmonary clearance technique. The four were exposed to polluted air on a heavily trafficked freeway or at a local dry-cleaning establishment, then spent the next 10 h in a clean-air environmental chamber. Breath and chamber-air samples were collected at regular intervals throughout the 10-h period and analyzed for the presence of selected target compounds. The breath levels of two of the compounds were elevated and decreased slowly with time once the subjects began to breathe clean air. Nonlinear least-squares fitting of the decay-uptake curves permitted the calculation of biological half-lives. Several of the target compounds occurred, however, at very low levels, and the resultant experimental scatter limited the value of these measurements. Higher initial exposures to most of the target compounds would have improved the reliability of the estimates.

  19. Parametric Evaluation of an Innovative Ultra-Violet PhotocatalyticOxidation (UVPCO) Air Cleaning Technology for Indoor Applications

    Energy Technology Data Exchange (ETDEWEB)

    Hodgson, Alfred T.; Sullivan, Douglas P.; Fisk, William J.

    2005-10-31

    An innovative Ultra-Violet Photocatalytic Oxidation (UVPCO) air cleaning technology employing a semitransparent catalyst coated on a semitransparent polymer substrate was evaluated to determine its effectiveness for treating mixtures of volatile organic compounds (VOCs) representative of indoor environments at low, indoor-relevant concentration levels. The experimental UVPCO contained four 30 by 30-cm honeycomb monoliths irradiated with nine UVA lamps arranged in three banks. A parametric evaluation of the effects of monolith thickness, air flow rate through the device, UV power, and reactant concentrations in inlet air was conducted for the purpose of suggesting design improvements. The UVPCO was challenged with three mixtures of VOCs. A synthetic office mixture contained 27 VOCs commonly measured in office buildings. A building product mixture was created by combining sources including painted wallboard, composite wood products, carpet systems, and vinyl flooring. The third mixture contained formaldehyde and acetaldehyde. Steady state concentrations were produced in a classroom laboratory or a 20-m{sup 3} chamber. Air was drawn through the UVPCO, and single-pass conversion efficiencies were measured from replicate samples collected upstream and downstream of the reactor. Thirteen experiments were conducted in total. In this UVPCO employing a semitransparent monolith design, an increase in monolith thickness is expected to result in general increases in both reaction efficiencies and absolute reaction rates for VOCs oxidized by photocatalysis. The thickness of individual monolith panels was varied between 1.2 and 5 cm (5 to 20 cm total thickness) in experiments with the office mixture. VOC reaction efficiencies and rates increased with monolith thickness. However, the analysis of the relationship was confounded by high reaction efficiencies in all configurations for a number of compounds. These reaction efficiencies approached or exceeded 90% for alcohols, glycol

  20. 空压机冷却器结垢原因分析及清洗%Cause Analysis and Cleaning of Air Compressor Cooler Scale Formation

    Institute of Scientific and Technical Information of China (English)

    冀成; 臧克培; 任彦峰

    2014-01-01

    针对空压机长时间运行会在冷却器中产生水垢,使冷却器堵塞导致进、排气温度升高,空气不能被冷却到预定温度,将严重影响空压机运行效率,分析了屯兰矿空压机房的2台ZH10000离心式空压机冷却器结垢的原因,阐述了其清洗原理、清洗溶液的配置浓度、搭建循环清洗冷却器的装置及清洗流程等。通过清洗,除垢效果、腐蚀率等指标均达到了空压机运行要求,确保了空压机的安全经济运转,为该矿井下压风系统的可靠稳定运行提供了保障。%The long running of air compressor can lead to water scale in cooler,to the cooler blocking,the tem-perature of inlet and exhaust increment.The air can not be cooled to the predetermined temperature,will seriously in-fluence the operational efficiency of air compressor.Analyzes the scale formation reason of Tunlan coal mine two ZH10000 centrifugal air compressor cooler,expounds the cleaning principle,concentration of the cleaning solution configuration,build cleaning cycle cooler devices and cleaning processes and so on.By cleaning the indicators such as descaling effect,corrosion rate all reach the compressor operating requirements,It ensures the safe and economic operation of air compressor,provides guarantee for the reliable and stable operation of downhole pressure wind system.

  1. Wash Solution Bath Life Extension for the Space Shuttle Rocket Motor Aqueous Cleaning System

    Science.gov (United States)

    Saunders, Chad; Evans, Kurt; Sagers, Neil

    1999-01-01

    A spray-in-air aqueous cleaning system, which replaced 1,1,1 trichloroethane (TCA) vapor degreasing, is used for critical cleaning of Space Shuttle Redesigned Solid Rocket Motor (RSRM) metal parts. Small-scale testing demonstrated that the alkaline-based wash solution possesses adequate soil loading and cleaning properties. However, full-scale testing exhibited unexpected depletion of some primary components of the wash solution. Specifically, there was a significant decrease in the concentration of sodium metasilicate which forced change-out of the wash solution after eight days. Extension of wash solution bath life was necessary to ease the burden of frequent change-out on manufacturing. A laboratory study supports a depletion mechanism that is initiated by the hydrolysis of sodium tripolyphosphate (STPP) lowering the pH of the solution. The decrease in pH causes polymerization and subsequent precipitation of sodium metasilicate (SM). Further investigation showed that maintaining the pH was the key to preventing the precipitation of the sodium metasilicate. Implementation to the full scale operation demonstrated that periodic additions of potassium hydroxide (KOH) extended the useful bath life to more than four months.

  2. Strategy Guideline. Compact Air Distribution Systems

    Energy Technology Data Exchange (ETDEWEB)

    Burdick, Arlan [IBACOS, Inc., Pittsburgh, PA (United States)

    2013-06-01

    This guideline discusses the benefits and challenges of using a compact air distribution system to handle the reduced loads and reduced air volume needed to condition the space within an energy efficient home. The decision criteria for a compact air distribution system must be determined early in the whole-house design process, considering both supply and return air design. However, careful installation of a compact air distribution system can result in lower material costs from smaller equipment, shorter duct runs, and fewer outlets; increased installation efficiencies, including ease of fitting the system into conditioned space; lower loads on a better balanced HVAC system, and overall improved energy efficiency of the home.

  3. Development and Application of Ultrasonic Cleaning System in Nuclear Power Industry

    International Nuclear Information System (INIS)

    The project was started to develop an ultrasonic means for removing sludge deposit in steam generators. However, more steam generators is being replaced or planned to be replaced soon. Increasing cleaning efficiency has become not very important at this stage. Therefore, we studied various fields in nuclear industry where ultrasonic cleaning technology is applicable. Development of ultrasonic cleaning system for removing sludge deposit on tube-sheet of SG is completed. Transducers are modified to protect tubes from damage. Sludge processing system is designed to remove solid particles in removed sludge deposit. Application of ultrasonic cleaning system in three areas including fuel cleaning system, decommissioning system, and decontamination system is suggested. Ultrasonic fuel cleaning system is designed and applied for patent

  4. Influence of Regional Development Policies and Clean Technology Adoption on Future Air Pollution Exposure

    OpenAIRE

    Hixson, Mark; Mahmud, Abdullah; Hu, Jianlin; Bai, Song; Niemeier, Debbie A.; Susan L Handy; Gao, Shengyi; Jay R. Lund; Sullivan, Dana C; M. J. Kleeman

    2010-01-01

    Future air pollution emissions in the year 2030 were estimated for the San Joaquin Valley (SJV) in central California using a combined system of land use, mobile, off-road, stationary, area, and biogenic emissions models. Four scenarios were developed that use different assumptions about the density of development and level of investment in transportation infrastructure to accommodate the expected doubling of the SJV population in the next 20 years. Scenario 1 reflects current land-use patter...

  5. Comparison between Different Air Distribution Systems

    DEFF Research Database (Denmark)

    Nielsen, Peter V.

    The aim of an air conditioning system is to remove excess heat in a room and replace room air with fresh air to obtain a high air quality. It is not sufficient to remove heat and contaminated air, it is also necessary to distribute and control the air movement in the room to create thermal comfort...... in the occupied zone. Most air distribution systems are based on mixing ventilation with ceiling or wall-mounted diffusers or on displacement ventilation with wall-mounted low velocity diffusers. New principles for room air distribution were introduced during the last decades, as the textile...... terminals mounted in the ceiling and radial diffusers with swirling flow also mounted in the ceiling. This paper addresses five air distribution systems in all, namely mixing ventilation from a wallmounted terminal, mixing ventilation from a ceiling-mounted diffuser, mixing ventilation from a ceiling...

  6. The effect of the recently enacted Clean Air Act amendments on the need for reviving the nuclear energy option

    Energy Technology Data Exchange (ETDEWEB)

    Sillin, J.O. (Management Analysis Co., San Diego, CA (United States))

    1991-01-01

    This paper reports on the 1990 Clean Air Act Amendments (CAAA) which accelerate the time table for reviving the nuclear energy option. While the full implications of the CAAA cannot be ascertained, it will certainly make it difficult (and in some regions, impossible) to increase electrical output from coal-fired power plants to meet growing electrical requirements. If nuclear energy is not available to meet these increased requirements, economic growth could falter and perhaps stagnate.

  7. Clean Air Now, But a Hazy Future: Tobacco Industry Political Influence and Tobacco Policy Making in Ohio 1997-2007

    OpenAIRE

    Gregory Tung, MPH; Stanton Glantz, PhD

    2007-01-01

    EXECUTIVE SUMMARY From 1997-2006 the tobacco industry and tobacco trade organizations contributed $464,700 to Ohio state political candidates and political parties, including $88,400 during the 2005-6 election. From 1997-2006 the tobacco industry and tobacco trade organizations made 77.2% of their total contributions to individuals and organizations affiliated with the Republican Party. Starting in 2000, health advocates made attempts to introduce clean indoor air regulations to all public an...

  8. Clean Air Now, But a Hazy Future: Tobacco Industry Political Influence and Tobacco Policy Making in Ohio 1997-2007

    OpenAIRE

    Gregory Tung, MPH; Stanton Glantz, PhD

    2007-01-01

    EXECUTIVE SUMMARY From 1997-2006 the tobacco industry and tobacco trade organizations contributed $464,700 to Ohio state political candidates and political parties, including $88,400 during the 2005-6 election. From 1997-2006 the tobacco industry and tobacco trade organizations made 77.2% of their total contributions to individuals and organizations affiliated with the Republican Party. Starting in 2000, health advocates made attempts to introduce clean indoor air r...

  9. Design and operation of off-gas cleaning and ventilation systems in facilities handling low and intermediate level radioactive material

    International Nuclear Information System (INIS)

    The number of developing countries constructing new nuclear facilities is increasing. These facilities include the production and processing of radioisotopes, as well as all types of laboratories and installations, which handle radioactive material and deal with the treatment of radioactive wastes. Ventilation and air cleaning systems are a vital part of the general design of any nuclear facility. The combination of a well designed ventilation system with thorough cleaning of exhaust air is the main method of preventing radioactive contamination of the air in working areas and in the surrounding atmosphere. This report provides the latest information on the design and operation of off-gas cleaning and ventilation systems for designers and regulatory authorities in the control and operation of such systems in nuclear establishments. The report presents the findings of an Advisory Group Meeting held in Vienna from 1 to 5 December 1986 and attended by 12 experts from 11 Member States. Following this meeting, a revised report was prepared by the International Atomic Energy Agency Secretariat and three consultants, M.J. Kabat (Canada), W. Stotz (Federal Republic of Germany) and W.A. Fairhurst (United Kingdom). The final draft was commented upon and approved by the participants of the meeting. 69 refs, 37 figs, 12 tabs

  10. Strategy Guideline: Compact Air Distribution Systems

    Energy Technology Data Exchange (ETDEWEB)

    Burdick, A.

    2013-06-01

    This Strategy Guideline discusses the benefits and challenges of using a compact air distribution system to handle the reduced loads and reduced air volume needed to condition the space within an energy efficient home. Traditional systems sized by 'rule of thumb' (i.e., 1 ton of cooling per 400 ft2 of floor space) that 'wash' the exterior walls with conditioned air from floor registers cannot provide appropriate air mixing and moisture removal in low-load homes. A compact air distribution system locates the HVAC equipment centrally with shorter ducts run to interior walls, and ceiling supply outlets throw the air toward the exterior walls along the ceiling plane; alternatively, high sidewall supply outlets throw the air toward the exterior walls. Potential drawbacks include resistance from installing contractors or code officials who are unfamiliar with compact air distribution systems, as well as a lack of availability of low-cost high sidewall or ceiling supply outlets to meet the low air volumes with good throw characteristics. The decision criteria for a compact air distribution system must be determined early in the whole-house design process, considering both supply and return air design. However, careful installation of a compact air distribution system can result in lower material costs from smaller equipment, shorter duct runs, and fewer outlets; increased installation efficiencies, including ease of fitting the system into conditioned space; lower loads on a better balanced HVAC system, and overall improved energy efficiency of the home.

  11. 77 FR 53772 - Approval and Promulgation of Air Quality Implementation Plans; Washington; Determination of Clean...

    Science.gov (United States)

    2012-09-04

    ... 2009-2011 monitoring data. On July 5, 2012 (77 FR 39657), EPA proposed a determination of clean data...; Determination of Clean Data for the 2006 24-Hour Fine Particulate Standard for the Tacoma, Pierce County... action'' subject to review by the Office of Management and Budget under Executive Order 12866 (58...

  12. Regulatory policy issues and the Clean Air Act: Issues and papers from the state implementation workshops

    Energy Technology Data Exchange (ETDEWEB)

    Rose, K. [ed.; Burns, R.E.

    1993-07-01

    The National Regulatory Research Institute (NRRI), with funding from the US Environmental Protection Agency (EPA) and the US Department of Energy (DOE), conducted four regional workshops` on state public utility commission implementation of the Clean Air Act Amendments of 1990 (CAAA). The workshops had four objectives: (1) to discuss key issues and concerns on CAAA implementation, (2) to encourage a discussion among states on issues of common interests, (3) to attempt to reach consensus, where possible, on key issues, and (4) to provide the workshop participants with information and materials to assist in developing state rules, orders, and procedures. From the federal perspective, a primary goal was to ensure that workshop participants return to their states with a comprehensive background and understanding of how state commission actions may affect implementation of the CAAA and to be able to provide guidance to their jurisdictional utilities. It was hoped that this would reduce some of the uncertainty utilities face and assist in the development of an efficient allowance market. This report is divided into two main sections. In Section II, eleven principal issues are identified and discussed. These issues were chosen because they were either the most frequently discussed or they were related to the questions asked in response to the speakers` presentations. This section does not cover all the issues relevant to state implementation nor all the issues discussed at the workshops; rather, Section II is intended to provide an overview of the,planning, ratemaking, and multistate issues. Part III is a series of workshop papers presented by some of the speakers. Individual papers have been cataloged separately.

  13. Allowance trading under the Clean Air Act: Who should regulate, and when?

    Energy Technology Data Exchange (ETDEWEB)

    Lock, R. [LeBoeuf, Lamb, Leiby & MacRae, Washington, DC (United States)

    1993-07-01

    The goal of this paper is to explore how compliance with the Clean Air Act Amendments of 1990 (CAAA), especially Title IV and emission trading under it, will affect the current relationship between state and federal regulation. It is difficult, with the limited experience we have had under Title IV, to be definitive about or to be a very strong advocate of too many policy positions. What may be most helpful at this point is to identify where the difficult issues in state/federal relations might arise; and then to explore ways in which tensions might be either avoided or resolved. One anticipated conclusion is that a traditional regulatory mindset could be very destructive if applied to this new area of oversight without due sensitivity to what Congress is trying to achieve in Title IV. That concern pervaded the early legislative debates; and it persists today. Title IV presents some unique challenges to state regulators and will require some creative solutions and fresh thinking if the goals of Congress are to be realized and the full benefits that allowance trading can offer are to be reaped by electricity consumers. In the ultimate analysis, Title IV amounts to a massive internalization of the external costs imposed on society by acid rain deposition. (This places in serious question the notion of additional externality {open_quotes}adders{close_quotes} for sulfur dioxide (SO{sub 2}) and nitrous oxide (NO{sub x}) at the state level for utility supply planning purposes.) The whole point of Title IV is to give those directly charged with compliance, namely power producers, the maximum flexibility to pursue least-cost compliance solutions. Perhaps the biggest single factor in how well they do this will be how state regulators respond to their compliance and allowance trading initiatives.

  14. An analysis of SO2 emission compliance under the 1990 Clean Air Act Amendments

    International Nuclear Information System (INIS)

    The effectiveness of SO2 emission allowance trading under Title 4 of the 1990 Amendments to the Clean Air Act (CAA) is of great interest due to the innovative nature of this market incentive approach. However, it may be a mistake to frame the compliance problem for a utility as a decision to trade or not. Trading of allowances should be the consequence, not the decision. The two meaningful decision variables for a utility are the control approaches chosen for its units and the amount of allowances to hold in its portfolio of assets for the future. The number allowances to be bought or sold (i.e. traded) is determined by the emission reduction and banking decisions. Our preferred approach is to think of the problem in terms of ABC's of the 1990 CAA Amendments: abatement strategy, banking, and cost competitiveness. The implications of the general principles presented in this paper on least cost emission reductions and emissions banking to hedge against risk are being simulated with version 2 of the ARGUS model representing the electric utility sector and regional coal supplies and transportation rates. A rational expectations forecast for allowances prices is being computed. The computed allowance price path has the property that demand for allowances by electric utilities for current use or for banking must equal the supply of allowances issued by the federal government or provided as forward market contracts in private market transactions involving non-utility speculators. From this rational expectations equilibrium forecast, uncertainties are being explored using sensitivity tests. Some of the key issues are the amount of scrubbing and when it is economical to install it, the amount of coal switching and how much low sulfur coal premiums will be bid up; and the amount of emission trading within utilities and among different utilities

  15. Regulatory policy issues and the Clean Air Act: An interim report on the state implementation workshops

    Energy Technology Data Exchange (ETDEWEB)

    Rose, K.; Burns, R.E.

    1992-08-01

    The National Regulatory Research Institute (NRRI), with funding from the U.S. Environmental Protection Agency (EPA) and U.S. Department of Energy (DOE), conducted two workshops on state public utility commission implementation of the Clean Air Act Amendments of 1990 (CAAA). The first workshop was held in Charlotte, North Carolina for southern and eastern states in April 1992 and the second was held in St. Louis, Missouri for Midwestern states in May. The workshops had four objectives: (1) discuss key issues and concerns on CAAA implementation, (2) encourage a discussion among states on issues of common interest, (3) attempt to reach consensus, where possible, on some key issues, and (4) provide the workshop participants with information and materials to assist in developing rules, orders, and procedures in their state. Of primary interest from the federal perspective was for workshop participants to return to their states with additional background and understanding of how state commission actions may affect implementation of the CAAA and enable them to provide guidance to their jurisdictional utilities. It was hoped this would reduce some of the uncertainty utilities face and assist in the development of an efficient allowance market. The basic format of the workshops was that invited speakers made presentations on specific issues. {open_quotes}Primary participants{close_quotes} from each state and other workshop attendees then discussed the issues raised by the speakers and other related concerns. The primary participants were state commissioners, commission staff, representatives from state consumer advocate organizations, EPA, DOE, and the Federal Energy Regulatory Commission (FERC). Other attendees were utility representatives, consultants, and other interested parties. All participants were given a workbook with excerpts from an NRRI report on CAAA implementation and papers or outlines from speakers.

  16. Cleaning space debris with a space-based laser system

    Institute of Scientific and Technical Information of China (English)

    Shen Shuangyan; Jin Xing; Chang Hao

    2014-01-01

    High-energy pulsed laser radiation may be the most feasible means to mitigate the threat of collision of a space station or other valuable space assets with orbital debris in the size range of 1-10 cm. Under laser irradiation, part of the debris material is ablated and provides an impulse to the debris particle. Proper direction of the impulse vector either deflects the object trajectory or forces the debris on a trajectory through the upper atmosphere, where it burns up. Most research concentrates on ground-based laser systems but pays little attention to space-based laser systems. There are drawbacks of a ground-based laser system in cleaning space debris. Therefore the placement of a laser system in space is proposed and investigated. Under assumed conditions, the elimination process of space debris is analyzed. Several factors such as laser repetition frequency, relative movement between the laser and debris, and inclination of debris particles which may exercise influence to the elimination effects are discussed. A project of a space-based laser system is proposed according to the numerical results of a computer study. The proposed laser system can eliminate debris of 1-10 cm and succeed in protecting a space station.

  17. Cleaning space debris with a space-based laser system

    Directory of Open Access Journals (Sweden)

    Shen Shuangyan

    2014-08-01

    Full Text Available High-energy pulsed laser radiation may be the most feasible means to mitigate the threat of collision of a space station or other valuable space assets with orbital debris in the size range of 1–10 cm. Under laser irradiation, part of the debris material is ablated and provides an impulse to the debris particle. Proper direction of the impulse vector either deflects the object trajectory or forces the debris on a trajectory through the upper atmosphere, where it burns up. Most research concentrates on ground-based laser systems but pays little attention to space-based laser systems. There are drawbacks of a ground-based laser system in cleaning space debris. Therefore the placement of a laser system in space is proposed and investigated. Under assumed conditions, the elimination process of space debris is analyzed. Several factors such as laser repetition frequency, relative movement between the laser and debris, and inclination of debris particles which may exercise influence to the elimination effects are discussed. A project of a space-based laser system is proposed according to the numerical results of a computer study. The proposed laser system can eliminate debris of 1–10 cm and succeed in protecting a space station.

  18. We Care for Clean Air! The Contribution of ACCENT to Education and Communication

    Science.gov (United States)

    Schuepbach, Eva; Brimblecombe, Peter; Gross, Krisjanis; Jacobs, Mark J.; Ladstätter-Weißenmayer, Annette; Moussiopoulos, Nicolas; Slini, Theodora; Übelis, Arnolds; Uherek, Elmar

    2010-05-01

    A new booklet on: "We Care for Clean Air! Motivating the Next Generation of Atmospheric Scientists" (ISBN 978-88-95665-01-6) as recently published by the education community in ACCENT (www.accent-network.org/portal/education) is presented. Promoting creative and innovative researchers and teachers and encouraging the next generation to move into the field were among the key issues in ACCENT "Training and Education" (T&E). During the 5-year programme, a wealth of educational events (e.g., workshops) and programmes (e.g., "ACCENT FAR EAST") were organized and tools developed for teachers and learners at Universities and Schools around the globe. Activities such as National ACCENT Days or Cafés Scientifiques also targeted stakeholders, policy makers and the general public to increase the expertise in atmospheric composition change to a common level across Europe. The volume introduces the integrated learning environment, high-quality tools and methods for air quality and climate change science education created by ACCENT T&E, and provides an overview on the unbiased scientific information that has been didactically translated based on knowledge available from ongoing research projects.The core messages are that (i) the translation of complex issues in atmospheric composition and climate change science to non-scientists should be scientifically acceptable and that (ii) scientists should stay in control of the translation process. After the publication of the 4th Assessment Report of the Intergovernmental Panel for Climate Change (IPCC) in 2007, ACCENT intensified its efforts to reach greater visibility and distribute the body of know-how, skills and competencies within the networked community of atmospheric scientists in the World Wide Web. For example, a Special Issue of the "Global Change Magazine for Schools" on IPCC 2007 contains a compact introduction to the basics of global warming for direct application in the classroom, also focusing on uncertainties and

  19. Air-Cleaning Operational Experience in the Bhabha Atomic Research Centre, Trombay

    International Nuclear Information System (INIS)

    The details of the operational experience gathered in the Bhabha Atomic Research Centre on various aspects of the problem associated with the control of pollutants from the operation of nuclear facilities housed therein form the subject of this report. A short account of the standards for radioactive gaseous waste management and the general practices concerning the prevention and control of air contamination is given. Studies on airborne radioactivity and the operational experience of the ventilation systems connected with some of the installations at Trombay are reviewed. The cost aspects of a typical ventilation system of an operating plant are presented. (author)

  20. Solid State Air Purification System Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The purpose of this proposed research is to develop a new air purification system based on a liquid membrane, capable of purifying carbon dioxide from air in a far...

  1. Improvement of self-cleaning type air filter%自洁式空气过滤器的改进

    Institute of Scientific and Technical Information of China (English)

    王鹏

    2012-01-01

    The self-cleaning type air filter is fitted before air inlet pipe of air compressor completed for air separation plant. The domestic-made carriage has low service life, and in case of highly wet air the filter paper is liable to stick, which lowers the filtering efficiency, results in frequent repair of air compressor repair, and seriously impairs prolonged stable run of air separation plant. The service life of carriage of self-cleaning type air filter is extended and the filtering efficiency is improved through use of the non-woven filtering cotton blended with compound fiber, the carriage made of compound fiber, and the imported filter paper, adjustment of its programmable controller, and change of its back-blowing pressure and air supply. Here, the work principle of self- cleaning type air filter is briefed, the problems during its operation process are analyzed, and the implementation process and economic benefits of the improvement measures are described.%空分设备配套空压机进气管前设置自洁式空气过滤器,由于国内生产的滤筒使用寿命短,遇含湿量大的空气时滤纸易黏连,进而影响过滤效率,导致空压机检修频繁,严重影响了空分设备长周期稳定运行。通过增加复合纤维无纺滤棉,选用复合纤维滤筒和进口滤纸,调整自洁式空气过滤器的编程控制仪,以及改变反吹压力和反吹气源,达到延长自洁式空气过滤器的滤筒寿命和提高过滤效率的目的。简述自洁式空气过滤器的工作原理,分析其使用过程中存在的问题,阐述改进措施的实施过程及取得的经济效益。

  2. Spray-dryer flue-gas-cleaning systems handbook

    Energy Technology Data Exchange (ETDEWEB)

    Huang, H.; Allen, J.W.; Livengood, C.D.; Davis, W.T. (Tennessee Univ., Knoxville, TN (USA). Dept. of Civil Engineering); Farber, P.S. (Chemical Waste Management, Inc., Oakbrook, IL (USA))

    1988-04-01

    Flue-gas cleaning systems based on spray drying are a recent development in pollution-control technology and have not been generally applied to combustion systems burning high-sulfur coal. However, Argonne National Laboratory has been operating a spray-dryer/fabric-filter system for the control of SO{sub 2} and particulate matter from a 20 MW (equivalent) stoker-fired boiler for about seven years, using coals with sulfur contents as high as 4.5%. Information acquired during that time, which could be useful to designers, builders, and operators of such systems, is presented. A summary of important equipment and process design considerations, a discussion of economic criteria (with guidance for making preliminary cost estimates), a review of operating and maintenance experiences at Argonne, and suggestions for structuring and carrying out the procurement of such a system are also included. In addition, recent research, such as sorbent activity enhancement and the combined control of SO{sub 2} and NO{sub x}, are briefly reviewed. 80 refs., 24 figs., 17 tabs.

  3. California Clean Air Act: A compliance strategy for the City of San Diego`s non-emergency fleet

    Energy Technology Data Exchange (ETDEWEB)

    1992-12-31

    Historically, parts of California have had the worst air quality in the nation. The California Energy Commission began experimenting with alternate fuels in the 1970`s in an effort to reduce harmful automobile emissions and hence, improve air quality. It is recognized that the costs to California which result from our air quality problems are immense. Ten to twenty billion dollars each year is the estimated damage in terms of health impacts, materials damages, lost agricultural crop output and forest damages. As the California population increases and health care costs escalate, the total monetary damages from air pollution will increase. The California Energy Commission goal to improve air quality became a mandate in 1988 with the passage of the California Clean Air Act (CCAA). The CCAA requires a revised air quality strategy for the San Diego district since we do not meet State air quality standards for smog, carbon monoxide and nitrogen dioxide. Smog remains San Diego`s major air quality problem, even though the annual number of days each year over the Federal standard has been reduced by 55 percent in the past ten years. Ten years ago about two-thirds of San Diego`s smog was transported from Los Angeles. Today more than 60 per cent of the days San Diego exceeds the State standard are from locally generated smog. It is estimated that 57% of the reactive hydrocarbon emissions (which react with nitrogen dioxide in the presence of sunlight to form smog) is from cars, trucks and buses. The Air Pollution Control District (part of the County of San Diego) is the office that the Air Resources Board has put in charge of creating regulations and designing strategy to reduce polluting emissions. The purpose of this project is to determine the full cost of acquiring and operating a municipal fleet which meets the mandates of the California Clean Air Act. With that information, a plan to meet the Clear Air Act (CCAA) requirements can be formulated by local government.

  4. Hybrid SBR–FO system for wastewater treatment and reuse: Operation, fouling and cleaning

    KAUST Repository

    Linares, Rodrigo Valladares

    2016-04-05

    Forward osmosis (FO) is a novel membrane separation process that potentially can be used as an energy-saving alternative to conventional membrane processes. A hybrid sequential batch reactor (SBR)–FO process was explored. In this system, a plate and frame FO cell including two flat-sheet FO membranes was submerged in a bioreactor treating synthetic domestic wastewater. The dissolved organic carbon (DOC) removal efficiency of the system was 98.55%. Total nitrogen removal was 62.4%, with nitrate, nitrite and ammonium removals of 58.4%, 96.2% and 88.4%, respectively. Phosphate removal was almost 100%. The 15-hour cycle average water flux of a virgin membrane with air scouring was 2.95 L/m2·h− 1. Air scouring can help to remove loose foulants from the membrane active layer, thus helping to recover up to 89.5% of the original flux. Chemical cleaning of the fouled active layer of the FO membrane was not as effective as air scouring. Natural organic matter (NOM) characterization methods (liquid chromatography–organic carbon detection (LC–OCD) and 3-D fluorescence excitation emission matrix (FEEM)) show that the FO membrane has a very good performance in rejecting biopolymers, humics and building blocks, but a limited ability in rejecting low molecular weight neutrals. Transparent exopolymer particles (TEP) and other biopolymers might be associated with fouling of the membrane on the support layer. A 1% sodium hypochlorite (NaOCl) cleaning solution was proved to be effective for removing the foulants from the support layer and recovering the original flux.

  5. Industrial Compressed Air System Energy Efficiency Guidebook.

    Energy Technology Data Exchange (ETDEWEB)

    United States. Bonneville Power Administration.

    1993-12-01

    Energy efficient design, operation and maintenance of compressed air systems in industrial plants can provide substantial reductions in electric power and other operational costs. This guidebook will help identify cost effective, energy efficiency opportunities in compressed air system design, re-design, operation and maintenance. The guidebook provides: (1) a broad overview of industrial compressed air systems, (2) methods for estimating compressed air consumption and projected air savings, (3) a description of applicable, generic energy conservation measures, and, (4) a review of some compressed air system demonstration projects that have taken place over the last two years. The primary audience for this guidebook includes plant maintenance supervisors, plant engineers, plant managers and others interested in energy management of industrial compressed air systems.

  6. Seeing Through Smoke: Sorting through the Science and Politics in the Making of the 1956 British Clean Air Act (Invited)

    Science.gov (United States)

    Kenny, D. A.

    2010-12-01

    The 1952 “Killer Smog” left over 4000 citizens of Greater London dead in a single week. It was a highly visible environmental disaster, which pinned the British government with responsibility over factory and domestic coal smoke pollution. Within four years of the Smog, the British parliament passed the 1956 Clean Air Act, which was designed primarily to prevent the release of dark smoke from the chimneys of private dwellings and factories. This act is considered a significant turning point in the history of environmental regulation. Through the analysis of confidential documents from government ministries and Members of Parliament, my research has focused on how decisions were made following this man-made environmental catastrophe. The primary focus of this presentation will be to explore why the British government appeared lethargic in the face of its long-standing coal pollution problem and why it finally passed the first clean air act in the world. In this case, establishing responsibility and organizing research were the major time constraints on policy action. In the months following the 1952 Smog, government departments passed off responsibility and quarreled over jurisdiction in the smog matter. Ministries held responsible for air pollution jointly established the Committee on Air Pollution to find a solution to urban smog. In the years following, the Committee on Air Pollution compiled research on the health effects and economic impact of air pollution, deriving its information from a variety of sources. In its 1954 final report, the committee named smoke and sulfur dioxide the most likely culprits of the 1952 deaths, and it recommended the elimination of smoke-producing coal from the British market, a major change to how the British fueled their homes and factories. The resulting 1956 Clean Air Act was the product of numerous compromises over the economic, political, and social issues present in Great Britain at the time. The British government

  7. Economics of water injected air screw compressor systems

    Science.gov (United States)

    Venu Madhav, K.; Kovačević, A.

    2015-08-01

    There is a growing need for compressed air free of entrained oil to be used in industry. In many cases it can be supplied by oil flooded screw compressors with multi stage filtration systems, or by oil free screw compressors. However, if water injected screw compressors can be made to operate reliably, they could be more efficient and therefore cheaper to operate. Unfortunately, to date, such machines have proved to be insufficiently reliable and not cost effective. This paper describes an investigation carried out to determine the current limitations of water injected screw compressor systems and how these could be overcome in the 15-315 kW power range and delivery pressures of 6-10 bar. Modern rotor profiles and approach to sealing and cooling allow reasonably inexpensive air end design. The prototype of the water injected screw compressor air system was built and tested for performance and reliability. The water injected compressor system was compared with the oil injected and oil free compressor systems of the equivalent size including the economic analysis based on the lifecycle costs. Based on the obtained results, it was concluded that water injected screw compressor systems could be designed to deliver clean air free of oil contamination with a better user value proposition than the oil injected or oil free screw compressor systems over the considered range of operations.

  8. 78 FR 17229 - Notice of Lodging of Proposed Consent Decree Amendment Under the Clean Air Act; the Clean Water...

    Science.gov (United States)

    2013-03-20

    ...-owned wastewater treatment plant. The violations occurred at a chemical manufacturing facility located...; conduct vacuum stripping of wastewater streams to remove methylene chloride; install an automated diffused aeration rate system in its wastewater treatment plant; implement an enhanced leak detection program;...

  9. Robust self-cleaning surfaces that function when exposed to either air or oil

    OpenAIRE

    Lu, Y

    2015-01-01

    Superhydrophobic self-cleaning surfaces are based on the surface micro/nanomorphologies; however, such surfaces are mechanically weak and stop functioning when exposed to oil. We have created an ethanolic suspension of perfluorosilane-coated titanium dioxide nanoparticles that forms a paint that can be sprayed, dipped, or extruded onto both hard and soft materials to create a self-cleaning surface that functions even upon emersion in oil. Commercial adhesives were used to bond the paint to va...

  10. Prevention of airborne disposal from staff in the O.R. reducing the risk of infection : what are the benefits of using clean air suits or scrub suits?

    OpenAIRE

    Abreu, Maria José Araújo Marques

    2012-01-01

    Experts in infection control are often asked about issues related to the use of scrubs and clean air suits in the operating room (OR). So, what are clean air suits and scrub suits? This article seeks to highlight the most relevant information of this products and try to define the benefits of using them for preventing airborne disposal from the surgical staff, reducing the risk of infection. No scientific data support the practice of using scrub suits as a means for preventing transmis...

  11. Fungal colonization of air-conditioning systems

    Directory of Open Access Journals (Sweden)

    Ljaljević-Grbić Milica

    2008-01-01

    Full Text Available Fungi have been implicated as quantitatively the most important bioaerosol component of indoor air associated with contaminated air-conditioning systems. rarely, indoor fungi may cause human infections, but more commonly allergenic responses ranging from pneumonitis to asthma-like symptoms. From all air conditioner filters analyzed, 16 fungal taxa were isolated and identified. Aspergillus fumigatus causes more lethal infections worldwide than any other mold. Air-conditioning filters that adsorb moisture and volatile organics appear to provide suitable substrates for fungal colonization. It is important to stress that fungal colonization of air-conditioning systems should not be ignored, especially in hospital environments.

  12. Air cleaning in clean rooms. Super-cleaning of mini-environments by UV/photoelectron method; Clean room ni okeru kuki seijo. UV/hikari denshiho ni yoru kyokusho kukan no cho clean ka

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, T.; Suzuki, T. [Ebara Research Co. Ltd., Kanagawa (Japan); Sakamoto, K. [Saitama Univearsity, Saitama (Japan); Yokoyama, Ss.; Hirose, M. [Hiroshima University, Hiroshima (Japan)

    2000-04-20

    Prevention of wafer surface contamination is an important issue in semiconductor manufacturing as such contamination decreases LSI productivity. Although particulate contamination in work rooms is being reduced by newer cleanroom techniques, there are still sources of particulate contaminants, such as wafer delivering systems, wafer stockers, and load-lock chambers. Not only fine particles but also gaseous contaminants need to be controlled. The following introduces an outlook on various methods of removing such particle and gaseous contaminants. (author)

  13. Gas turbines: gas cleaning requirements for biomass-fired systems

    Directory of Open Access Journals (Sweden)

    Oakey John

    2004-01-01

    Full Text Available Increased interest in the development of renewable energy technologies has been hencouraged by the introduction of legislative measures in Europe to reduce CO2 emissions from power generation in response to the potential threat of global warming. Of these technologies, biomass-firing represents a high priority because of the modest risk involved and the availability of waste biomass in many countries. Options based on farmed biomass are also under development. This paper reviews the challenges facing these technologies if they are to be cost competitive while delivering the supposed environmental benefits. In particular, it focuses on the use of biomass in gasification-based systems using gas turbines to deliver increased efficiencies. Results from recent studies in a European programme are presented. For these technologies to be successful, an optimal balance has to be achieved between the high cost of cleaning fuel gases, the reliability of the gas turbine and the fuel flexibility of the overall system. Such optimisation is necessary on a case-by-case basis, as local considerations can play a significant part.

  14. System for sterilizing objects. [cleaning space vehicle systems

    Science.gov (United States)

    Bryan, C. J.; Wright, E. E., Jr.; Moyers, C. V. (Inventor)

    1981-01-01

    A system for producing a stream of humidified sterilizing gas for sterilizing objects such as the water systems of space vehicles and the like includes a source of sterilant gas which is fed to a mixing chamber which has inlet and outlet ports. The level of the water only partially fills the mixing chamber so as to provide an empty space adjacent the top of the chamber. A heater is provided for heating the water in the chamber so as to produce a humidified atmosphere. The sterilant gas is fed through an arcuate shaped tubular member connected to the inlet port of the mixing chamber for producing a vortex type of flow of sterilant gas into the chamber for humidification. A tubular member extends from the mixing chamber for supplying the humidified sterilant gas to the object for being sterilized. Scrubbers are provided for removing the sterilant gas after use.

  15. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT; ULTRASONIC AQUEOUS CLEANING SYSTEMS, SMART SONIC CORPORATION, SMART SONIC

    Science.gov (United States)

    This report is a product of the U.S. EPA's Environmental Technoloy Verification (ETV) Program and is focused on the Smart Sonics Ultrasonic Aqueous Cleaning Systems. The verification is based on three main objectives. (1) The Smart Sonic Aqueous Cleaning Systems, Model 2000 and...

  16. Control system design of high-voltage live cleaning robot based on security

    Institute of Scientific and Technical Information of China (English)

    谢霄鹏; 夏红卫; 杨汝清

    2004-01-01

    High-voltage live cleaning robot works in the hot-line environment (220 kV/330 kV), and so the safety of its application and equipment is most important. In terms of safety, the designs of robot mechanism and control system have been discussed, and the test data are given in control system of model machine. The model machine of high-voltage live cleaning robot can meet the need of cleaning basically in common condition. From manual operation to automation, the cleaning efficiency is improved. The robot can decrease amount of work, and ensure the security. Among high-voltage live cleaning equipment in China, the cleaning robot is advanced in automation and intelligence.

  17. Fighting ambient air pollution and its impact on health: from human rights to the right to a clean environment.

    Science.gov (United States)

    Guillerm, N; Cesari, G

    2015-08-01

    Clean air is one of the basic requirements of human health and well-being. However, almost nine out of 10 individuals living in urban areas are affected by air pollution. Populations living in Africa, South-East Asia, and in low- and middle-income countries across all regions are the most exposed. Exposure to outdoor air pollution ranks as the ninth leading risk factor for mortality, killing 3.2 million people each year, especially young children, the elderly, persons with lung or cardiovascular disease, those who work or exercise outdoors and low-income populations. In October 2013, the International Agency for Research on Cancer (IARC) classified outdoor air pollution as carcinogenic to humans, calling air pollution 'a major environmental health problem'. Human rights and environmental norms are powerful tools to combat air pollution and its impact on health. The dependence of human rights on environmental quality has been recognised in international texts and by human rights treaty bodies. The growing awareness of the environment has already yielded considerable legislative and regulatory output. However, the implementation of standards remains a pervasive problem. In the fight against violations of norms, citizens have a crucial role to play. We discuss the relevance of a yet to be proclaimed standalone right to a healthy environment. PMID:26162353

  18. Compliance with the Clean Air Act Amendments: Challenge of the 90's

    International Nuclear Information System (INIS)

    With its 17,593 miles of pipeline, El Paso Natural Gas Company is one of the country's largest interstate natural gas transmission companies. To keep the gas continually moving through the pipeline, it is compressed back to high pressures at 73 stations comprising 1,210,120 horsepower located along the pipeline route. These compressor stations, which operate 24 hours a day every day, house 316 reciprocating engines and 92 gas turbines. As fuel, these engines and turbines burn natural gas. Natural gas combustion releases emissions of nitrogen oxides and carbon monoxide with small amounts of particulates, sulfur dioxide and volatile organic compounds. This presentation will describe how one large energy company plans to comply with these new requirements over the next several years. El Paso has developed an extensive Air Program designed to obtain all needed operating permits by the November 1995 deadline. Work is underway to quantify and document emissions at every operating facility. Emissions tests will measure NOx, CO, oxygen, CO2, water, stack temperature, stack velocity and fuel flow rate. Data generated by the Emissions Inventory System will be used not only for permit applications, but to develop alternative emission reduction strategies at facilities located in nonattainment areas. Dispersion modeling will be performed to analyze compliance with PSD increments and National Ambient Air Quality Standards

  19. Repellent materials. Robust self-cleaning surfaces that function when exposed to either air or oil.

    Science.gov (United States)

    Lu, Yao; Sathasivam, Sanjayan; Song, Jinlong; Crick, Colin R; Carmalt, Claire J; Parkin, Ivan P

    2015-03-01

    Superhydrophobic self-cleaning surfaces are based on the surface micro/nanomorphologies; however, such surfaces are mechanically weak and stop functioning when exposed to oil. We have created an ethanolic suspension of perfluorosilane-coated titanium dioxide nanoparticles that forms a paint that can be sprayed, dipped, or extruded onto both hard and soft materials to create a self-cleaning surface that functions even upon emersion in oil. Commercial adhesives were used to bond the paint to various substrates and promote robustness. These surfaces maintained their water repellency after finger-wipe, knife-scratch, and even 40 abrasion cycles with sandpaper. The formulations developed can be used on clothes, paper, glass, and steel for a myriad of self-cleaning applications. PMID:25745169

  20. Robust self-cleaning surfaces that function when exposed to either air or oil

    Science.gov (United States)

    Lu, Yao; Sathasivam, Sanjayan; Song, Jinlong; Crick, Colin R.; Carmalt, Claire J.; Parkin, Ivan P.

    2015-03-01

    Superhydrophobic self-cleaning surfaces are based on the surface micro/nanomorphologies; however, such surfaces are mechanically weak and stop functioning when exposed to oil. We have created an ethanolic suspension of perfluorosilane-coated titanium dioxide nanoparticles that forms a paint that can be sprayed, dipped, or extruded onto both hard and soft materials to create a self-cleaning surface that functions even upon emersion in oil. Commercial adhesives were used to bond the paint to various substrates and promote robustness. These surfaces maintained their water repellency after finger-wipe, knife-scratch, and even 40 abrasion cycles with sandpaper. The formulations developed can be used on clothes, paper, glass, and steel for a myriad of self-cleaning applications.

  1. REAL TIME WIRELESS AIR POLLUTION MONITORING SYSTEM

    OpenAIRE

    Raja Vara Prasad Y; Mirza Sami Baig; Mishra, Rahul K; Rajalakshmi, P.; U. B. Desai; S. N. Merchant

    2011-01-01

    Air pollution has significant influence on the concentration of constituents in the atmosphere leading to effects like global warming and acid rains. To avoid such adverse imbalances in the nature, an air pollution monitoring system is utmost important. This paper attempts to develop an effective solution for pollution monitoring using wireless sensor networks (WSN) on a real time basis namely real time wireless air pollution monitoring system. Commercially available discrete gas sensors for ...

  2. 75 FR 9206 - Science Advisory Board Staff Office; Notification of a Clean Air Scientific Advisory Committee...

    Science.gov (United States)

    2010-03-01

    ... the Carbon Monoxide Primary National Ambient Air Quality Standards: Second External Review Draft and EPA's Policy Assessment for the Review of the Carbon Monoxide National Ambient Air Quality Standards... consultative advice on EPA's Plan for Review of the National Ambient Air Quality Standards for Carbon......

  3. Preliminary calculations for the CAFE project (Clean Air For Europe); Calculs preparatoires pour la strategie thematique CAFE (Clean Air For Europe)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-09-15

    The European Commission decided in 2001 an analysis program to reduce the atmospheric emissions. This report presents different limit scenari for France in 2020 (the reference scenari and the MTFR scenari, Maximum Technically Feasible Reduction), optimized scenari calculated by the RAINS model (Regional Air Pollution Information and Simulation), the costs of the scenari calculated with RAINS and the cost-benefit analysis of the strategy CAFE. From the study results, the benefits are higher than the costs, even with the most ambitious scenari. At an european level the emission reduction strategies have no effect on the employment but an impact on the Gross Domestic Product (decrease between 0,04 % and 0,12 % in function of the scenari). (A.L.B.)

  4. Rooftop Unitary Air Conditioner with Integral Dedicated Outdoor Air System

    Energy Technology Data Exchange (ETDEWEB)

    Tiax Llc

    2006-02-28

    Energy use of rooftop and other unitary air-conditioners in commercial applications accounts for about 1 quad (10{sup 15} Btu) of primary energy use annually in the U.S. [Reference 7]. The realization that this cooling equipment accounts for the majority of commercial building cooled floorspace and the majority also of commercial building energy use has spurred development of improved-efficiency equipment as well as development of stricter standards addressing efficiency levels. Another key market driver affecting design of rooftop air-conditioning equipment has been concern regarding comfort and the control of humidity. Trends for increases in outdoor air ventilation rates in certain applications, and the increasing concern about indoor air quality problems associated with humidity levels and moisture in buildings points to a need for improved dehumidification capability in air-conditioning equipment of all types. In many cases addressing this issue exacerbates energy efficiency, and vice versa. The integrated dedicated outdoor air system configuration developed in this project addresses both energy and comfort/humidity issues.

  5. Air pollution control systems in WtE units: an overview.

    Science.gov (United States)

    Vehlow, J

    2015-03-01

    All WtE (waste-to-energy) plants, based on combustion or other thermal processes, need an efficient gas cleaning for compliance with legislative air emission standards. The development of gas cleaning technologies started along with environment protection regulations in the late 1960s. Modern APC (air pollution control) systems comprise multiple stages for the removal of fly ashes, inorganic and organic gases, heavy metals, and dioxins from the flue gas. The main technologies and devices used for abatement of the various pollutants are described and their basic principles, their peculiarities, and their application are discussed. Few systems for cleaning of synthesis gas from waste gasification plants are included. Examples of APC designs in full scale plants are shown and cautious prospects for the future development of APC systems are made. PMID:25022549

  6. 75 FR 17003 - Reconsideration of Interpretation of Regulations That Determine Pollutants Covered by Clean Air...

    Science.gov (United States)

    2010-04-02

    ... Deterioration (PSD) Permit Program (Dec. 18, 2008) (``PSD Interpretive Memo'' or ``Memo''); see also 73 FR 80300... findings for GHGs under section 202(a) of the CAA. See 74 FR 66495. On November 13, 2008, the Environmental... Reconsideration, In the Matter of: EPA Final Action Published at 73 FR 80300 (Dec. 31, 2008), entitled ``Clean...

  7. The clean air act amendments of 1990 and the national energy strategy of 1991 in relation to district heating and cooling

    International Nuclear Information System (INIS)

    District heating and cooling (DHC) has a good side with regard to the environment, as one system replaces many individual boilers and furnaces that together would emit a larger amount of uncontrolled, environmentally damaging substances than the DHC power plant. However, the more controlled emissions from the power plant are more visible and concentrated and are carried on by winds to longer distances. The Clean Air Act Amendments of 1990 set definite goals for reducing harmful emissions, and the power plants must gradually improve their plants and operations to follow these new guidelines. Similarly, the National Energy Strategy calls for adherence to the purposes of the Clean Air Act, but at the same time it provides some trade-offs in order to allow more time for the construction and installation of more effective equipment. As the use of electricity has increased tenfold in the United States during the past 40 years and the electricity producing power plants are usually only about 30 % fuel efficient, the emissions from the fuel that is used to burn and generate electricity-with two-thirds of it wasted-have multiplied enormously. To harness the wasted energy by utilizing district heating and cooling could greatly improve environmental conditions and conserve large amounts of energy

  8. Optical air data systems and methods

    Science.gov (United States)

    Caldwell, Loren M. (Inventor); Tang, Shoou-yu (Inventor); Acott, Phillip E. (Inventor); Spaeth, Lisa G. (Inventor); O'Brien, Martin (Inventor)

    2011-01-01

    Systems and methods for sensing air includes at least one, and in some embodiments three, transceivers for projecting the laser energy as laser radiation to the air. The transceivers are scanned or aligned along several different axes. Each transceiver receives laser energy as it is backscattered from the air. A computer processes signals from the transceivers to distinguish molecular scattered laser radiation from aerosol scattered laser radiation and determines air temperatures, wind speeds, and wind directions based on the scattered laser radiation. Applications of the system to wind power site evaluation, wind turbine control, traffic safety, general meteorological monitoring and airport safety are presented.

  9. Results of the Test Program for Replacement of AK-225G Solvent for Cleaning NASA Propulsion Oxygen Systems

    Science.gov (United States)

    Lowrey, Nikki M.; Mitchell, Mark A.

    2016-01-01

    Since the 1990's, when the Class I Ozone Depleting Substance chlorofluorocarbon-113 was banned, NASA's propulsion test facilities at Marshall Space Flight Center and Stennis Space Center have relied upon the solvent Asahiklin AK-225 (hydrochlorofluorocarbon-225ca/cb or HCFC-225ca/cb) and, more recently AK-225G (the single isomer form, HCFC-225cb) to safely clean and verify the cleanliness of large scale propulsion oxygen systems. Effective January 1, 2015, the production, import, export, and new use of Class II Ozone Depleting Substances, including AK-225G, was prohibited in the United States by the Clean Air Act. In 2012 through 2014, NASA test labs at MSFC, SSC, and Johnson Space Center's White Sands Test Facility collaborated to seek out, test, and qualify a solvent replacement for AK-225G that is both an effective cleaner and safe for use with oxygen systems. This paper summarizes the tests performed, results, and lessons learned.

  10. Air leakage in residential solar heating systems

    Science.gov (United States)

    Shingleton, J. G.; Cassel, D. E.; Overton, R. L.

    1981-02-01

    A series of computer simulations was performed to evaluate the effects of component air leakage on system thermal performance for a typical residential solar heating system, located in Madison, Wisconsin. Auxiliary energy required to supplement solar energy for space heating was determined using the TRNSYS computer program, for a range of air leakage rates at the solar collector and pebble bed storage unit. The effects of heat transfer and mass transfer between the solar equipment room and the heated building were investigated. The effect of reduced air infiltration into the building due to pressurized by the solar air heating system were determined. A simple method of estimating the effect of collector array air leakage on system thermal performance was evaluated, using the f CHART method.

  11. Cleaning residual NaK in the fast flux test facility fuel storage cooling system

    International Nuclear Information System (INIS)

    scrubber through the stack and due to the temperature of the gas, the hydrogen auto ignited when it mixed with the oxygen in the air. There was no damage to equipment, no injuries, and no significant release of hazardous material. Even though the FSF Cooling System is the only system at FFTF that contains residual NaK, there are lessons to be learned from this event that can be applied to future residual sodium removal activities. The lessons learned are: - Before cleaning equipment containing residual alkali metal the volume of alkali metal in the equipment should be minimized to the extent practical. As much as possible, reconfirm the amount and location of the alkali metal immediately prior to cleaning, especially if additional evolutions have been performed or significant time has passed. This is especially true for small diameter pipe (<20.3 centimeters diameter) that is being cleaned in place since gas flow is more likely to move the alkali metal. Potential confirmation methods could include visual inspection (difficult in all-metal systems), nondestructive examination (e.g., ultrasonic measurements) and repeating previous evolutions used to drain the system. Also, expect to find alkali metal in places it would not reasonably be expected to be. - Staff with an intimate knowledge of the plant equipment and the bulk alkali metal draining activities is critical to being able to confirm the amount and locations of the alkali metal residuals and to safely clean the residuals. - Minimize the potential for movement of alkali metal during cleaning or limit the distance and locations into which alkali metal can move. - Recognize that when working with alkali metal reactions, occasional pops and bangs are to be anticipated. - Pre-plan emergency responses to unplanned events to assure responses planned for an operating reactor are appropriate for the deactivation phase

  12. Human Exposure Assessment in Air Pollution Systems

    OpenAIRE

    Junfeng Zhang; Lioy, Paul J.

    2002-01-01

    The air pollution problem can be depicted as a system consisting of several basic components: source, concentration, exposure, dose, and adverse effects. Exposure, the contact between an agent (e.g., an air pollutant) and a target (e.g., a human respiratory tract), is the key to linking the pollution source and health effects. Human exposure to air pollutants depends on exposure concentration and exposure duration. Exposure concentration is the concentration of a pollutant at a contact bounda...

  13. 77 FR 41930 - Bleed Air Cleaning and Monitoring Equipment and Technology

    Science.gov (United States)

    2012-07-17

    ... technology for the engine and auxiliary power unit bleed air supplied to the passenger cabin and flight deck... Privacy Act Statement can be found in the Federal Register published on April 11, 2000 (65 FR 19477-19478... of removing oil-based contaminants from the bleed air supplied to the passenger cabin and flight...

  14. Gas Cleaning System with a Pre-Unloading Flow

    Science.gov (United States)

    Vasilevsky, Michail; Razva, Aleksandr; Roman, Baev; Alibek, Asan

    2016-02-01

    The analysis of the causes and mechanisms reduce the efficiency of processes separation in cyclone devices, the results of field surveys of industrial cyclone. It offers an alternative solution to clean the flue gases from the boiler KE-10/14.

  15. CLEAN WATER STATE REVOLVING FUND NATIONAL INFORMATION MANAGEMENT SYSTEM (NIMS)

    Science.gov (United States)

    Resource Purpose:Data collected annually from EPA Regional Offices and States on the 51 Clean Water State Revolving Fund (CWSRF) programs. The data provides the Agency with information on sources and uses of CWSRF funds to finance wastewater management projects, nonpoint ...

  16. Gas Cleaning System with a Pre-Unloading Flow

    Directory of Open Access Journals (Sweden)

    Vasilevsky Michail

    2016-01-01

    Full Text Available The analysis of the causes and mechanisms reduce the efficiency of processes separation in cyclone devices, the results of field surveys of industrial cyclone. It offers an alternative solution to clean the flue gases from the boiler KE-10/14.

  17. The Search for Nonflammable Solvent Alternatives for Cleaning Aerospace Oxygen Systems

    Science.gov (United States)

    Mitchell, Mark; Lowrey, Nikki

    2012-01-01

    Oxygen systems are susceptible to fires caused by particle and nonvolatile residue (NVR) contaminants, therefore cleaning and verification is essential for system safety. . Cleaning solvents used on oxygen system components must be either nonflammable in pure oxygen or complete removal must be assured for system safety. . CFC -113 was the solvent of choice before 1996 because it was effective, least toxic, compatible with most materials of construction, and non ]reactive with oxygen. When CFC -113 was phased out in 1996, HCFC -225 was selected as an interim replacement for cleaning propulsion oxygen systems at NASA. HCFC-225 production phase-out date is 01/01/2015. HCFC ]225 (AK ]225G) is used extensively at Marshall Space Flight Center and Stennis Space Center for cleaning and NVR verification on large propulsion oxygen systems, and propulsion test stands and ground support equipment. . Many components are too large for ultrasonic agitation - necessary for effective aqueous cleaning and NVR sampling. . Test stand equipment must be cleaned prior to installation of test hardware. Many items must be cleaned by wipe or flush in situ where complete removal of a flammable solvent cannot be assured. The search for a replacement solvent for these applications is ongoing.

  18. Air conditioning for data processing system areas

    Directory of Open Access Journals (Sweden)

    Hernando Camacho García

    2011-06-01

    Full Text Available The appropiate selection of air conditioners for data processing system areas requires the knowledge of the environmental desing conditions, the air conditioning systems succssfully used computer and the cooling loads to handle. This work contains information about a wide variety of systems designed for computer room applications. a complete example of calculation to determine the amount of heat to be removed for satisfactory operation, is also included.

  19. Air pollution restrictions in electrical production system

    International Nuclear Information System (INIS)

    A description of the principal characteristics regarding the Italian electrical power system and the evolution of standardization in air pollution control is given. Afterwards, ENEL (the Italian National Electricity Board) actions in the environmental protection field (with particular respect to thermo-electrical production) are presented. Finally, principal ENEL research programs on new air pollution control technologies are discussed

  20. Heating, ventilation and air conditioning system modelling

    Energy Technology Data Exchange (ETDEWEB)

    Whalley, R.; Abdul-Ameer, A. [British University in Dubai (United Arab Emirates)

    2011-03-15

    Heating, ventilation and air conditioning modelling methods, for large scale, spatially dispersed systems are considered. Existing techniques are discussed and proposals for the application of novel analysis approaches are outlined. The use of distributed-lumped parameter procedures enabling the incorporation of the relatively concentrated and significantly dispersed, system element characteristics, is advocated. A dynamic model for a heating, ventilation and air conditioning system comprising inlet and exhaust fans, with air recirculation, heating/cooling and filtration units is presented. Pressure, airflow and temperature predictions within the system are computed following input, disturbance changes and purging operations. The generalised modelling advancements adopted and the applicability of the model for heating, ventilation and air conditioning system simulation, re-configuration and diagnostics is emphasised. The employment of the model for automatic, multivariable controller design purposes is commented upon. (author)

  1. Serious Gaming for Test & Evaluation of Clean-Slate (Ab Initio) National Airspace System (NAS) Designs

    Science.gov (United States)

    Allen, B. Danette; Alexandrov, Natalia

    2016-01-01

    Incremental approaches to air transportation system development inherit current architectural constraints, which, in turn, place hard bounds on system capacity, efficiency of performance, and complexity. To enable airspace operations of the future, a clean-slate (ab initio) airspace design(s) must be considered. This ab initio National Airspace System (NAS) must be capable of accommodating increased traffic density, a broader diversity of aircraft, and on-demand mobility. System and subsystem designs should scale to accommodate the inevitable demand for airspace services that include large numbers of autonomous Unmanned Aerial Vehicles and a paradigm shift in general aviation (e.g., personal air vehicles) in addition to more traditional aerial vehicles such as commercial jetliners and weather balloons. The complex and adaptive nature of ab initio designs for the future NAS requires new approaches to validation, adding a significant physical experimentation component to analytical and simulation tools. In addition to software modeling and simulation, the ability to exercise system solutions in a flight environment will be an essential aspect of validation. The NASA Langley Research Center (LaRC) Autonomy Incubator seeks to develop a flight simulation infrastructure for ab initio modeling and simulation that assumes no specific NAS architecture and models vehicle-to-vehicle behavior to examine interactions and emergent behaviors among hundreds of intelligent aerial agents exhibiting collaborative, cooperative, coordinative, selfish, and malicious behaviors. The air transportation system of the future will be a complex adaptive system (CAS) characterized by complex and sometimes unpredictable (or unpredicted) behaviors that result from temporal and spatial interactions among large numbers of participants. A CAS not only evolves with a changing environment and adapts to it, it is closely coupled to all systems that constitute the environment. Thus, the ecosystem that

  2. 14 CFR 23.1111 - Turbine engine bleed air system.

    Science.gov (United States)

    2010-01-01

    ... using maximum bleed air must be established. (c) Hazardous contamination of cabin air systems may not... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Turbine engine bleed air system. 23.1111... Induction System § 23.1111 Turbine engine bleed air system. For turbine engine bleed air systems,...

  3. Essays on Infrastructure Design and Planning for Clean Energy Systems

    Science.gov (United States)

    Kocaman, Ayse Selin

    The International Energy Agency estimates that the number of people who do not have access to electricity is nearly 1.3 billion and a billion more have only unreliable and intermittent supply. Moreover, current supply for electricity generation mostly relies on fossil fuels, which are finite and one of the greatest threats to the environment. Rising population growth rates, depleting fuel sources, environmental issues and economic developments have increased the need for mathematical optimization to provide a formal framework that enables systematic and clear decision-making in energy operations. This thesis through its methodologies and algorithms enable tools for energy generation, transmission and distribution system design and help policy makers make cost assessments in energy infrastructure planning rapidly and accurately. In Chapter 2, we focus on local-level power distribution systems planning for rural electrification using techniques from combinatorial optimization. We describe a heuristic algorithm that provides a quick solution for the partial electrification problem where the distribution network can only connect a pre-specified number of households with low voltage lines. The algorithm demonstrates the effect of household settlement patterns on the electrification cost. We also describe the first heuristic algorithm that selects the locations and service areas of transformers without requiring candidate solutions and simultaneously builds a two-level grid network in a green-field setting. The algorithms are applied to real world rural settings in Africa, where household locations digitized from satellite imagery are prescribed. In Chapter 3 and 4, we focus on power generation and transmission using clean energy sources. Here, we imagine a country in the future where hydro and solar are the dominant sources and fossil fuels are only available in minimal form. We discuss the problem of modeling hydro and solar energy production and allocation, including

  4. Environmental health in China: challenges to achieving clean air and safe water

    OpenAIRE

    Zhang, Junfeng; Mauzerall, Denise L.; Zhu, Tong; Liang, Song; Ezzati, Majid; Remais, Justin

    2010-01-01

    The health effects of environmental risks, especially those of air and water pollution, remain a major source of morbidity and mortality in China. Biomass fuel and coal are routinely burned for cooking and heating in almost all rural and many urban households resulting in severe indoor air pollution that contributes greatly to the burden of disease. Many communities lack access to safe drinking water and santiation, and thus the risk of waterborne disease in many regions remains high. At the ...

  5. About sorption-catalytic air cleaning in premises for people habitation in megapolises

    Directory of Open Access Journals (Sweden)

    A.V. Cрechevichkin

    2011-01-01

    Full Text Available The basic sources of pollution of the air environment in megapolises, and also of internal atmosphere of premises for people habitation, in respect of their possible clearing by sorption-catalytic methods are systematized. Design and principle of action of the room sorption-catalytic three-chambered filter for clearing of turnaround air of a thermo premise of gaseous ammonia, hydrogen sulfide, carbon dioxide and organic substances are described.

  6. Plasma Air Decontamination System (PADS) Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed Plasma Air Decontamination System (PADS) is a trace contaminant control device based on non-thermal atmospheric pressure plasma technology that...

  7. Plasma Air Decontamination System (PADS) Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed Plasma Air Decontamination System (PADS) is a trace contaminant control device based on non-thermal atmospheric-pressure plasma technology. Compared to...

  8. Power System Challenge: Synthesis Report for the 7th Clean Energy Ministerial

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2016-06-01

    The Clean Energy Ministerial's (CEM's) Power System Challenge was established in 2015 to create a shared vision among major economies regarding the pathway to clean, reliable, resilient, and affordable power. Endorsing governments have created core principles and challenge propositions as a framework for government and industry action to support and guide power system transformation. This brochure details the status of the Challenge, how countries are working to meet the Challenge, and the relevant milestones reached by initiatives of the Clean Energy Ministerial.

  9. Discussion on cleaning and maintenance of YA system reverse osmosis membrane

    International Nuclear Information System (INIS)

    According to the overproof of pollution data of YA system reverse osmosis membrane in extension project, the daily maintenance company is using chemical cleaning on reverse osmosis unit to eliminate the pollution blindly, the fixed prescription, fixed dosage and high frequency of the chemical cleaning. The writer analyzed the cause of the membrane pollution and commended several chemical cleaning methods by the long-period study of the system, and also some suggestion, according to the status of operational site, for the daily maintenance. (author)

  10. Cleaning device for recycling pump motor cooling system in nuclear reactor

    International Nuclear Information System (INIS)

    The cleaning device of the present invention comprises a cleaning water supply pump, a filter for filtering the cleaning water and a cap member for isolating the inside of a motor casing from the inside of a reactor pressure vessel. A motor in the motor casing and a pump in the reactor pressure vessel are removed, the cap member is attached to the upper end of the motor casing to isolate the inside of the motor casing from the inside of the reactor pressure vessel. If the cleaning water supply pump is operated in this state, the cleaning water flows from a returning pipeline for cooling water circulation, connected to the motor casing to supply pipelines through a heat exchange and is discharged. The discharged water passes through a filter and is sent again, as the cleaning water, to the cleaning water supply pump. With such procedures, the recycling pump motor cooling system in the BWR type reactor can be cleaned without disposing a cyclone separator and irrespective of presence or absence of reactor coolants in the reactor pressure vessel. (I.N.)

  11. Air quality and future energy system planning

    Science.gov (United States)

    Sobral Mourao, Zenaida; Konadu, Dennis; Lupton, Rick

    2016-04-01

    Ambient air pollution has been linked to an increasing number of premature deaths throughout the world. Projected increases in demand for food, energy resources and manufactured products will likely contribute to exacerbate air pollution with an increasing impact on human health, agricultural productivity and climate change. Current events such as tampering emissions tests by VW car manufacturers, failure to comply with EU Air Quality directives and WHO guidelines by many EU countries, the problem of smog in Chinese cities and new industrial emissions regulations represent unique challenges but also opportunities for regulators, local authorities and industry. However current models and practices of energy and resource use do not consider ambient air impacts as an integral part of the planing process. Furthermore the analysis of drivers, sources and impacts of air pollution is often fragmented, difficult to understand and lacks effective visualization tools that bring all of these components together. This work aims to develop a model that links impacts of air quality on human health and ecosystems to current and future developments in the energy system, industrial and agricultural activity and patterns of land use. The model will be added to the ForeseerTM tool, which is an integrated resource analysis platform that has been developed at the University of Cambridge initially with funding from BP and more recently through the EPSRC funded Whole Systems Energy Modeling (WholeSEM) project. The basis of the tool is a set of linked physical models for energy, water and land, including the technologies that are used to transform these resources into final services such as housing, food, transport and household goods. The new air quality model will explore different feedback effects between energy, land and atmospheric systems with the overarching goal of supporting better communication about the drivers of air quality and to incorporate concerns about air quality into

  12. Radioactivity in the furnace air-cleaning filter from a house with an unusually high level of airborne radon

    International Nuclear Information System (INIS)

    The amounts of the three short-lived daughters of radon on the furnace air-cleaning filter from a house with a high level of radon were estimated to be 8.2, 33, and 38 kBq (0.22, 0.89, and 1.03 μCi) for 218Po, 214Pb, and 214Bi, respectively, at the time of removal from the furnace. These data were used to calculate the airborne concentrations of the three, and the results indicated that about 70% of the daughters were lost to surfaces in the house and by impaction in the air ducts. The filter's content of 210Pb was found to be 4.4 kBg (0.12 μCi); from this the average concentration of radon-producing filterable daughters during the time the furnace blower operated, was estimated to be 860 Bq m-3. This indicated that there was no significant loss to surfaces or in air ducts. Possible reasons for the difference are given. The filter was also found to contain 1 kBq (27 nCi) of 212Bi from the thorium series

  13. Air filtration and indoor air quality

    DEFF Research Database (Denmark)

    Bekö, Gabriel

    2006-01-01

    Demands for better indoor air quality are increasing, since we spend most of our time indoors and we are more and more aware of indoor air pollution. Field studies in different parts of the world have documented that high percentage of occupants in many offices and buildings find the indoor air...... decent ventilation and air cleaning/air filtration, high indoor air quality cannot be accomplished. The need for effective air filtration has increased with increasing evidence on the hazardous effects of fine particles. Moreover, the air contains gaseous pollutants, removal of which requires various air...... cleaning techniques. Supply air filter is one of the key components in the ventilation system. Studies have shown that used ventilation filters themselves can be a significant source of indoor air pollution with consequent impact on perceived air quality, sick building syndrome symptoms and performance...

  14. Human Response to Ductless Personalised Ventilation: Impact of Air Movement, Temperature and Cleanness on Eye Symptoms

    OpenAIRE

    Dalewski, Mariusz; Fillon, Maelys; Bivolarova, Maria; Melikov, Arsen Krikor

    2013-01-01

    The performance of ductless personalized ventilation (DPV) in conjunction with displacement ventilation (DV) was studied in relation to peoples’ health, comfort and performance. This paper presents results on the impact of room air temperature, using of DPV and local air filtration on eye blink rate and tear film quality. In a test room with DV and six workstations 30 human subjects were exposed for four hours to each of the following 5 experimental conditions: 23 °C and DV only, 23 °C and DP...

  15. The Value of Clean Air in China: Evidence from Beijing and Shanghai

    OpenAIRE

    Jijun Tan; Jinhua Zhao

    2014-01-01

    We estimate the willingness to pay (WTP) of Beijing and Shanghai residents for improving the air quality of the two cities from their levels prior to the 2008 Beijing Olympic Games to the level achieved during the Olympics. The data are obtained from a contingent valuation study conducted through face-to-face interviews in June 2008 in Beijing and Shanghai prior to the Beijing Olympics, during which time there was intensive debate about Beijing¡¯s air quality. Residents in both cities are wil...

  16. 49 CFR 570.57 - Air brake system and air-over-hydraulic brake subsystem.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 6 2010-10-01 2010-10-01 false Air brake system and air-over-hydraulic brake... STANDARDS Vehicles With GVWR of More Than 10,000 Pounds § 570.57 Air brake system and air-over-hydraulic brake subsystem. The following requirements apply to vehicles with air brake and...

  17. 75 FR 22787 - Proposed Settlement Agreement, Clean Air Act Citizen Suit

    Science.gov (United States)

    2010-04-30

    ... issuance of air permit No. 1740- 00025V1 to Waste Management for the Woodside Landfill in Walker.... and 4:30 p.m. Monday through Friday, excluding legal holidays. Comments on a disk or CD-ROM should be... to Waste Management for the Woodside Landfill in Walker, Livingston Parish Louisiana (the...

  18. 78 FR 56633 - Approval and Promulgation of Air Quality Implementation Plans; New York; Determination of Clean...

    Science.gov (United States)

    2013-09-13

    ... 885 (1/7/13) (Ogden Utah area); 71 FR 6352 (February 8, 2006) (Ajo, Arizona area); 71 FR 13021 (March... determines, after notice-and-comment rulemaking in the Federal Register (FR), that the area has violated the... with this FR action, that the air quality data shows attainment of the PM 10 NAAQS, is not...

  19. 78 FR 43200 - Proposed Settlement Agreement, Clean Air Act Citizen Suit

    Science.gov (United States)

    2013-07-19

    ... Defense Council, and Physicians for Social Responsibility-Los Angeles (collectively ``Petitioners'') in... 1997 8-hour ozone national ambient air quality standard in the South Coast. 77 FR 12674 (March 1, 2012... also noticed an appeal from dismissal of Physicians for Social Responsibility--Los Angeles v. EPA,...

  20. 76 FR 66718 - Clean Air Act Advisory Committee (CAAAC): Notice of Meeting

    Science.gov (United States)

    2011-10-27

    ..., please contact Pat Childers, Office of Air and Radiation, U.S. EPA (202) 564-1082, FAX (202) 564-1352 or... on access or services for individuals with disabilities, please contact Mr. Pat Childers at (202) 564-1082 or childers.pat@epa.gov . To request accommodation of a disability, please contact Mr....

  1. 78 FR 9388 - Clean Air Act Advisory Committee (CAAAC): Notice of Meeting

    Science.gov (United States)

    2013-02-08

    ... CONTACT: Concerning the CAAAC, please contact Pat Childers, Office of Air and Radiation, U.S. EPA (202.../ . For information on access or services for individuals with disabilities, please contact Mr. Pat Childers at (202) 564-1082 or childers.pat@epa.gov . To request accommodation of a disability,...

  2. Oil spill clean-up system using hot water

    International Nuclear Information System (INIS)

    The process of hot water extraction of tar sand was modified and adapted for removal of heavy oil from bottom tank petroleum sludges, and was submitted to a laboratory feasibility study. This process can also be utilized to clean beach sands contaminated by accidental heavy oil spills. The process mainly consists of a hot-water extraction (digestion), extruding the oil particles from their support of sand or clay. In the case of oil contaminated sands, a single stage extraction yielded a total recovery of hydrocarbons of 99% and a clean sand (hardly containing 0.1% of hydrocarbons), thus safe to be returned to the environment. In the case of heavy oil from bottom tank petroleum sludges, it was necessary to proceed with a double stage extraction with the addition of wetting agents: the utilization of Na2SiO3 aqueous solution of 1% in weight was proven efficient, allowing a 82% recovery of hydrocarbons, with only 0.5% hydrocarbons in the solid residues. 21 refs., 8 figs., 4 tabs

  3. US power plant carbon standards and clean air and health co-benefits

    Science.gov (United States)

    Driscoll, Charles T.; Buonocore, Jonathan J.; Levy, Jonathan I.; Lambert, Kathleen F.; Burtraw, Dallas; Reid, Stephen B.; Fakhraei, Habibollah; Schwartz, Joel

    2015-06-01

    Carbon dioxide emissions standards for US power plants will influence the fuels and technologies used to generate electricity, alter emissions of pollutants such as sulphur dioxide and nitrogen oxide, and influence ambient air quality and public health. We present an analysis of how three alternative scenarios for US power plant carbon standards could change fine particulate matter and ozone concentrations in ambient air, and the resulting public health co-benefits. The results underscore that carbon standards to curb global climate change can also provide immediate local and regional health co-benefits, but the magnitude depends on the design of the standards. A stringent but flexible policy that counts demand-side energy efficiency towards compliance yields the greatest health benefits of the three scenarios analysed.

  4. Clean Hydrogen Production via Novel Steam-Air Gasification of Biomass

    International Nuclear Information System (INIS)

    Gasification converts biomass into H2 and CO rich product gas by using air, oxygen and/or steam as reaction agent. An experimental and modelling study of hydrogen production was conducted using a laboratory scale counter-current fixed bed gasifier with preheated air and steam as the gasifying agents. Commercial charcoal was used as the fuel and the reactor bed was maintained at temperatures of 750-960 C by external heaters. H2 (17-28 vol%), CO (5-11 vol%) and CO2 (18-21 vol%) forms a large portion of the synthesis gas produced depending on the ratio of the gasifying agent. The experimental work was coupled with both equilibrium and kinetic modelling to predict the equilibrium composition, conversion rates and temperature profile. (authors)

  5. Operating experience feedback report - Air systems problems

    International Nuclear Information System (INIS)

    This report highlights significant operating events involving observed or potential failures of safety-related systems in U.S. plants that resulted from degraded or malfunctioning non-safety grade air systems. Based upon the evaluation of these events, the Office for Analysis and Evaluation of Operational Data (AEOD) concludes that the issue of air systems problems is an important one which requires additional NRC and industry attention. This report also provides AEOD's recommendations for corrective actions to deal with the issue. (author)

  6. Evaporative Condensers in Comfortable Air Conditioning System

    Institute of Scientific and Technical Information of China (English)

    YIN Ying-de; ZHU Dong-sheng; DU Gui-mei; LI Yuan-xi; SUN He-jing; LIU Qing-ming

    2009-01-01

    The operating theory of an evaporative condenser was expatiated.The difference between an e-vaporative condensing refrigeration system and a general refrigeration system was analyzed.Compared with the air-cooled and the water-cooled,the virtues of energy-conservation and water-conservation of evaporative con-densers were analyzed.Some questions existing in the application of evaporative condensers were pointed out,the corresponding solving methods were analyzed accordingly,and the development trend of evaporative con-densing technique in mechanical refrigeration system field and the applied foreground of evaporative condensers in comfortable air conditioning were prospected.

  7. The Integrated Air Transportation System Evaluation Tool

    Science.gov (United States)

    Wingrove, Earl R., III; Hees, Jing; Villani, James A.; Yackovetsky, Robert E. (Technical Monitor)

    2002-01-01

    Throughout U.S. history, our nation has generally enjoyed exceptional economic growth, driven in part by transportation advancements. Looking forward 25 years, when the national highway and skyway systems are saturated, the nation faces new challenges in creating transportation-driven economic growth and wealth. To meet the national requirement for an improved air traffic management system, NASA developed the goal of tripling throughput over the next 20 years, in all weather conditions while maintaining safety. Analysis of the throughput goal has primarily focused on major airline operations, primarily through the hub and spoke system.However, many suggested concepts to increase throughput may operate outside the hub and spoke system. Examples of such concepts include the Small Aircraft Transportation System, civil tiltrotor, and improved rotorcraft. Proper assessment of the potential contribution of these technologies to the domestic air transportation system requires a modeling capability that includes the country's numerous smaller airports, acting as a fundamental component of the National Air space System, and the demand for such concepts and technologies. Under this task for NASA, the Logistics Management Institute developed higher fidelity demand models that capture the interdependence of short-haul air travel with other transportation modes and explicitly consider the costs of commercial air and other transport modes. To accomplish this work, we generated forecasts of the distribution of general aviation based aircraft and GA itinerant operations at each of nearly 3.000 airport based on changes in economic conditions and demographic trends. We also built modules that estimate the demand for travel by different modes, particularly auto, commercial air, and GA. We examined GA demand from two perspectives: top-down and bottom-up, described in detail.

  8. 14 CFR 23.1109 - Turbocharger bleed air system.

    Science.gov (United States)

    2010-01-01

    ... Induction System § 23.1109 Turbocharger bleed air system. The following applies to turbocharged bleed air systems used for cabin pressurization: (a) The cabin air system may not be subject to hazardous... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Turbocharger bleed air system....

  9. Aerometric Information Retrieval System/AIRS Facility Subsystem (AIRS/AFS)

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Aerometric Information Retrieval System/AIRS Facility Subsystem (AIRS/AFS) is a database that provides information on air releases from various stationary...

  10. 40 CFR Appendix H to Subpart A of... - Clean Air Act Amendments of 1990 Phaseout Schedule for Production of Ozone-Depleting Substances

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 17 2010-07-01 2010-07-01 false Clean Air Act Amendments of 1990 Phaseout Schedule for Production of Ozone-Depleting Substances H Appendix H to Subpart A of Part 82... STRATOSPHERIC OZONE Production and Consumption Controls Pt. 82, Subpt. A, App. H Appendix H to Subpart A of...

  11. Decision document on the revision of the VERA protocol on air cleaning technologies. Measuring techniques for the determination of the removal efficiency for ammonia

    OpenAIRE

    Mosquera Losada, J.; Edouard, N.; Guiziou, F.; Melse, R.W.; Riis, A.L.; Sommer, S.; Brusselman, E.

    2014-01-01

    In the project “ICT-AGRI: Development of harmonized sampling and measurement methods for odour, ammonia and dust emissions” different subgroups have been formed focusing on either ammonia, odour or dust. In this report, the conclusions of the ammonia subgroup regarding harmonization of measurement methods for the estimation of the ammonia removal from air cleaning technologies are summarized.

  12. 40 CFR 49.4 - Clean Air Act provisions for which it is not appropriate to treat tribes in the same manner as...

    Science.gov (United States)

    2010-07-01

    ... is not appropriate to treat tribes in the same manner as States. 49.4 Section 49.4 Protection of... Tribal Authority § 49.4 Clean Air Act provisions for which it is not appropriate to treat tribes in the same manner as States. Tribes will not be treated as States with respect to the following provisions...

  13. 76 FR 43725 - Notice of Lodging of Consent Decree Under the Clean Air Act, Sections 113(b) and 304(a), 42 U.S.C...

    Science.gov (United States)

    2011-07-21

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF JUSTICE Notice of Lodging of Consent Decree Under the Clean Air Act, Sections 113(b) and 304(a), 42 U.S.C. 7413(b), 7604(a) Notice is hereby given that on July 13, 2009, a proposed Second Amendment Consent Decree...

  14. Evidential Reasoning in Air Battle Systems

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Bayesian statistics assigns basic probabilities to singletons (single element sets). The Dempster-Shafer evidence theory generalizes Bayesian statistics by assigning basic probabilities to subsets to represent evidence and to develop evidential reasoning. This paper discusses what is the strength of evidence theory. As an application of evidence theory, evidential reasoning in air battle systems is discussed. In the air battle system, evidential reasoning is applied to fuse the multisensor information and identify the type of aircraft. The effectiveness of this fusion approach is evaluated by simulated data.

  15. The Clean Air Act Amendments of 1990: An overview of sections affecting the power generation industry

    International Nuclear Information System (INIS)

    Although the Amendments contain 11 separate titles, it is likely that only six will directly impact the power generation industry. Of the six titles likely to have a direct impact, four deal with emissions, one establishes a new permit program, and one deals with a new enforcement program. In addition, some of the other provisions of the new law may have an indirect or future impact because they deal with such issues as a study of visibility impairment from power plant emissions, studies addressing the toxic emissions or hazardous waste aspects of coal use in power plants, an inventory of carbon dioxide (CO2) emissions from power plants and their global warming implications, research into power plant emissions monitoring, environmental health research, outer continental shelf air pollution, protection of the stratospheric ozone layer through a faster phaseout of CFCs, etc. The impacts of mobile source controls will be primarily on the carbon monoxide and ozone attainment status of areas and not power plants. The power plant impacts of the sections of the Amendments dealing with toxic air pollutants will, to a large extent, be a function of the fuels used, the source categories that are to be defined by EPA, and the EPA implementing regulations. As a result, this summary will be limited to non-attainment, acid rain control, the permit program and the enforcement provisions and their potential impacts on the power generation industry

  16. Overshooting of Clean Tropospheric Air in the Tropical Lower Stratosphere as Seen by the CALIPSO Lidar

    Science.gov (United States)

    Vernier, J. P.; Pommereau, J. P.; Thomason, L. W.; Pelon, J.; Garnier, A.; Deshler, T.; Jumelet, J.; Nielsen, J. K.

    2011-01-01

    The evolution of aerosols in the tropical upper troposphere/lower stratosphere between June 2006 and October 2009 is examined using the observations of the space borne CALIOP lidar aboard the CALIPSO satellite. Superimposed on several volcanic plumes and soot from an extreme biomass-burning event in 2009, the measurements reveal the existence of fast cleansing episodes of the lower stratosphere to altitudes as high as 20 km. The cleansing of the full 14-20km layer takes place within 1-4 months. Its coincidence with the maximum of convective activity in the southern tropics, suggests that the cleansing is the result of a large number of overshooting towers, injecting aerosol-poor tropospheric air into the lower stratosphere. The enhancements of aerosols at the tropopause level during the NH summer may be due to the same transport process but associated with intense sources of aerosols at the surface. Since, the tropospheric air flux derived from CALIOP observations during North Hemisphere winter is 5 20 times larger than the slow ascent by radiative heating usually assumed, the observations suggest that convective overshooting is a major contributor to troposphere-to-stratosphere transport with concommitant implications to the Tropical Tropopause Layer top height, chemistry and thermal structure.

  17. AIRMaster: Compressed air system audit software

    International Nuclear Information System (INIS)

    The project goal was to develop a software tool, AIRMaster, and a methodology for performing compressed air system audits. AIRMaster and supporting manuals are designed for general auditors or plant personnel to evaluate compressed air system operation with simple instrumentation during a short-term audit. AIRMaster provides a systematic approach to compressed air system audits, analyzing collected data, and reporting results. AIRMaster focuses on inexpensive Operation and Maintenance (O and M) measures, such as fixing air leaks and improving controls that can significantly improve performance and reliability of the compressed air system, without significant risk to production. An experienced auditor can perform an audit, analyze collected data, and produce results in 2--3 days. AIRMaster reduces the cost of an audit, thus freeing funds to implement recommendations. The AIRMaster package includes an Audit Manual, Software and User's manual, Analysis Methodology Manual, and a Case Studies summary report. It also includes a Self-Guided Tour booklet to help users quickly screen a plant for efficiency improvement potentials, and an Industrial Compressed Air Systems Energy Efficiency Guidebook. AIRMaster proved to be a fast and effective audit tool. In sever audits AIRMaster identified energy savings of 4,056,000 kWh, or 49.2% of annual compressor energy use, for a cost savings of $152,000. Total implementation costs were $94,700 for a project payback period of 0.6 years. Available airflow increased between 11% and 51% of plant compressor capacity, leading to potential capital benefits from 40% to 230% of first year energy savings

  18. Gas bubbling cleaning method

    International Nuclear Information System (INIS)

    The present invention concerns a gas bubbling cleaning method for objects to be cleaned having complicate shapes such as reactor equipments. For instance, air is used as the gas, while water is used as the cleaning fluid. A jetting air is jetted out to an object to be cleaned from an air bubbling nozzle disposed below the object. This constitutes air/water two phase flow near the object to be cleaned, to generate a three dimensional circulating flow. The distance between the inner wall surface of a cleaning vessel and the object to be cleaned is set to greater than 5 mm, and the ratio between the air flow rate and the horizontal cross section of the cleaning vessel is set to 0.1 to 0.4m/sec. This enables to enter an appropriate amount of bubbles to the air at the inside of the object to be cleaned having a complicate shape. Accordingly, deposits adhered to the inside of the object to be cleaned can be eliminated and cleaned effectively. (I.N.)

  19. Measurements of free radicals in a megacity during the Clean Air for London Project

    Science.gov (United States)

    Heard, Dwayne; Whalley, Lisa; Stone, Daniel; Clancy, Noel; Lee, James; Kleffman, Jorg; Laufs, Sebastian; Bandy, Brian

    2013-04-01

    Free radicals control the photo-oxidative chemistry of the atmosphere, being responsible for the transformation of primary emissions into secondary pollutants such as NO2, O3, multifunctional species and particulates. Here we present measurements of OH, HO2 and RO2 radicals and OH reactivity recorded at North Kensington, Central London, during two Intensive Operational Periods (IOPs) of the Clear Air for London (Clearflo) project in the summer and winter of 2012. OH and HO2 were measured using laser-induced fluorescence (LIF) spectroscopy at low pressure (the FAGE technique), and RO2 was measured using the recently developed ROXLIF technique, which utilises an external flow-reactor interfaced to FAGE, and which is able to discriminate between HO2 and organic peroxy radicals. Through control of reagent gases we are further able to provide a separate measurement of those RO2 species which are known to give an interference for HO2 measurements (namely alkene, aromatic and large-chain alkane derived RO2). OH reactivity was measured using laser-flash photolysis combined with FAGE. Low concentrations of radicals were observed during the winter IOP, with mixing ratios of [OH] ~ 0.04 pptv, [HO2] ~ 0.4 pptv, and [RO2] ~ 1.6 pptv at noon, all displaying a negative correlation with NO. The photolysis of O3 and subsequent reaction of O(1D) with H2O vapour was only a minor contribution to radical production in winter, with photolysis of HONO a major radical source. The summer IOP coincided with the London Olympic Games, with a number of pollution events, with ozone peaking at 100 ppbv (exceeding EU air quality directives) and elevated radical concentrations (peak [OH] ~ 0.14 pptv, [HO2] ~ 4 pptv, [RO2] ~ 6.4 pptv) being observed. The net rate of ozone production was calculated from radical observations and agreed well with measured ozone production, suggesting that advection/dilution by continental air-masses was not playing a significant role in determining ozone

  20. Combined air and water pollution control system

    Science.gov (United States)

    Wolverton, Billy C. (Inventor); Jarrell, Lamont (Inventor)

    1990-01-01

    A bioaquatic air pollution control system for controlling both water and atmospheric pollution is disclosed. The pollution control system includes an exhaust for directing polluted gases out of a furnace and a fluid circulating system which circulates fluid, such as waste water, from a source, past the furnace where the fluid flow entrains the pollutants from the furnace. The combined fluid and pollutants are then directed through a rock/plant/microbial filtering system. A suction pump pumps the treated waste water from the filter system past the exhaust to again entrain more pollutants from the furnace where they are combined with the fluid (waste water) and directed to the filter system.