WorldWideScience

Sample records for air abrasion dental

  1. Contact air abrasion.

    Science.gov (United States)

    Porth, R

    1999-05-01

    The advantages of contact air abrasion techniques are readily apparent. The first, of course, is the greatly increased ease of use. Working with contact also tends to speed the learning curve by giving the process a more natural dental feel. In addition, as one becomes familiar with working with a dust stream, the potential for misdirecting the air flow is decreased. The future use of air abrasion for deep decay removal will make this the treatment of choice for the next millennium.

  2. New concepts in air abrasion.

    Science.gov (United States)

    Porth, R N

    1998-03-01

    There is no doubt that air abrasion is going to be part of the millennial shift in dentistry away from traditional treatment modalities. With the change in incidence and morphology of caries as a result of the hardening effect of fluoride on enamel, this ability to remove only decayed areas and permanently seal the less susceptible areas becomes increasingly desirable.

  3. Air flow exploration of abrasive feed tube

    Science.gov (United States)

    Zhang, Shijin; Li, Xiaohong; Gu, Yilei

    2009-12-01

    An abrasive water-jet cutting process is one in which water pressure is raised to a very high pressure and forced through a very small orifice to form a very thin high speed jet beam. This thin jet beam is then directed through a chamber and then fed into a secondary nozzle, or mixing tube. During this process, a vacuum is generated in the chamber, and garnet abrasives and air are pulled into the chamber, through an abrasive feed tube, and mixes with this high speed stream of water. Because of the restrictions introduced by the abrasive feed tube geometry, a vacuum gradient is generated along the tube. Although this phenomenon has been recognized and utilized as a way to monitor nozzle condition and abrasive flowing conditions, yet, until now, conditions inside the abrasive feed line have not been completely understood. A possible reason is that conditions inside the abrasive feed line are complicated. Not only compressible flow but also multi-phase, multi-component flow has been involved in inside of abrasive feed tube. This paper explored various aspects of the vacuum creation process in both the mixing chamber and the abrasive feed tube. Based on an experimental exploration, an analytical framework is presented to allow theoretical calculations of vacuum conditions in the abrasive feed tube.

  4. The application of air abrasion in dentistry

    Directory of Open Access Journals (Sweden)

    Mandinić Zoran

    2014-01-01

    Full Text Available One of the main objectives of contemporary dentistry is to preserve healthy tooth structure by applying techniques of noninvasive treatment. Air abrasion is a minimally invasive nonmechanical technique of tooth preparation that uses kinetic energy to remove carious tooth structure. A powerful narrow stream of moving aluminum-oxide particles hit the tooth surface and they abrade it without heat, vibration or noise. Variables that affect speed of cutting include air pressure, particle size, powder flow, tip’s size, angle and distance from the tooth. It has been proposed that air abrasion can be used to diagnose early occlusal-surface lesions and treat them with minimal tooth preparation using magnifier. Reported advantages of air abrasion include reduced noise, vibration and sensitivity. Air abrasion cavity preparations have more rounded internal contours than those prepared with straight burs. This may increase the longevity of placed restorations because it reduces the incidence of fractures and a consequence of decreased internal stresses. However, air abrasion cannot be used for all patients, i.e. in cases involving severe dust allergy, asthma, chronic obstructive lung disease, recent extraction or other oral surgery, open wounds, advanced periodontal disease, recent placement of orthodontic appliances and oral abrasions, or subgingival caries removal. Many of these conditions increase the risk of air embolism in the oral soft tissues. Dust control is a challenge, and it necessitates the use of rubber dam, high-volume evacuation, protective masks and safety eyewear for both the patient and the therapist. [Projekat Ministarstva nauke Republike Srbije, br. 46009

  5. Abrasive wear and surface roughness of contemporary dental composite resin.

    Science.gov (United States)

    Han, Jian-min; Zhang, Hongyu; Choe, Hyo-Sun; Lin, Hong; Zheng, Gang; Hong, Guang

    2014-01-01

    The purpose of this study was to evaluate the abrasive wear and surface roughness of 20 currently available commercial dental composite resins, including nanofilled, supra-nanofilled, nanohybrid and microhybrid composite resins. The volume loss, maximum vertical loss, surface roughness (R(a)) and surface morphology [Scanning electron microscopy (SEM)] were determined after wear. The inorganic filler content was determined by thermogravimetric analysis. The result showed that the volume loss and vertical loss varied among the materials. The coefficients of determination (R(2)) of wear volume loss and filler content (wt%) was 0.283. SEM micrographs revealed nanofilled composites displayed a relatively uniform wear surfaces with nanoclusters protrusion, while the performance of nanohybrid composites varied. The abrasive wear resistance of contemporary dental composite resins is material-dependent and cannot be deduced from its category, filler loading and composite matrix; The abrasive wear resistance of some flowable composites is comparable to the universal/posterior composite resins.

  6. A new dimension to conservative dentistry: Air abrasion.

    Science.gov (United States)

    Hegde, Vivek S; Khatavkar, Roheet A

    2010-01-01

    Air abrasion dentistry has evolved over a period of time from a new concept of an alternative means of cavity preparation to an essential means of providing a truly conservative preparation for preservation of a maximal sound tooth structure. The development of bonded restorations in combination with air abrasion dentistry provides a truly minimal intervention dentistry. This article reviews the development of air abrasion, its clinical uses, and the essential accessories required for its use.

  7. A new dimension to conservative dentistry: Air abrasion

    Directory of Open Access Journals (Sweden)

    Hegde Vivek

    2010-01-01

    Full Text Available Air abrasion dentistry has evolved over a period of time from a new concept of an alternative means of cavity preparation to an essential means of providing a truly conservative preparation for preservation of a maximal sound tooth structure. The development of bonded restorations in combination with air abrasion dentistry provides a truly minimal intervention dentistry. This article reviews the development of air abrasion, its clinical uses, and the essential accessories required for its use.

  8. Soybean seedlings tolerate abrasion from air-propelled grit

    Science.gov (United States)

    New tools for controlling weeds would be useful for soybean production in organic systems. Air-propelled abrasive grit is one such tool that performs well for in-row weed control in corn, but crop safety in soybean is unknown. We examined responses to abrasion by corn-cob grit of soybean seedlings a...

  9. RESIZING OF THE CRANIOMANDIBULAR RELATION IN THE REHABILITATION OF DENTAL ABRASION

    Directory of Open Access Journals (Sweden)

    Delia BAHRIM

    2016-03-01

    Full Text Available Dental abrasion appears as a complex phenomenon among the multitude of clinical manifestations occurring in patients who require a complex oral rehabilitation. The therapeutical solutions for such cases are quite elaborate, involving interdisciplinary contributions from the part of various specialists.Obviously, elucidation of the complex cases of dental abrasion is possible when their standardized classification and, equally, a well-established therapeutical conduct, considering the class of dental abrasion, are available.Considering the advance of the adhesive techniques, the conservative treatment of dental abrasion is more indicated than the conventional method.Consequently, a 3-stage protocol of coronary reconstruction is recommended in cases of erosion with undersizing of the lower segment. The immediate aesthetic results are satisfacatory for the patient, as well as the functional ones, not requiring longer accomodation times. The reconstructions are resistant, due to the progress recorded by the adhesive techniques and composite resins (nano-hybrids, nano-composites.

  10. Patient preference: conventional rotary handpieces or air abrasion for cavity preparation.

    Science.gov (United States)

    Malmström, Hans S; Chaves, Yvette; Moss, Mark E

    2003-01-01

    It has been suggested that patients should accept the use of the air abrasion technique over the conventional handpiece due to the reduced need for anesthesia. Technologies for both air abrasion and the conventional rotary handpiece have, in recent decades, seen major improvements, but there are no recent scientific publications that evaluate the patient's preference for these two technologies when performing a cavity preparation. This study determined the patient's preference for air abrasion or the rotary handpiece for removing occlusal fissure carious lesions in mandibular premolars. Ten healthy subjects 18 years of age or older were recruited from the General Dentistry Clinic of the University of Rochester Eastman Dental Center, with fissure caries at a DEJ depth of similar size (determined by radiographs and clinical examination) in any two mandibular premolars in opposite quadrants. Within each subject, the two methods of caries removal were randomly assigned. In one premolar, air abrasion was used for cavity preparation, and in the other premolar, a conventional rotary handpiece was used. At each visit prior to treatment, the patients were instructed to complete the Emotional Status (ES) questionnaire (SUNY University at Buffalo Craniofacial Pain Clinic) to assess differences in their emotional status between appointments. At each appointment, when the restorative treatment was completed, patients were instructed to rate their pain on the Visual Analogue Scale (VAS). A technique preference questionnaire was given after the second appointment. The subjects rated the perception of pain as significantly lower (p cavity preparation when removing fissural caries in mandibular premolars and most subjects did not experience any pain when air abrasion was used.

  11. The effectiveness of the air-powder abrasive device on the tooth and periodontium: an overview.

    Science.gov (United States)

    Kozlovsky, A; Soldinger, M; Sperling, I

    1989-01-01

    The characteristics of the air-powder abrasive device (APAD) was reviewed from the current dental literature and found to be an excellent alternative to traditional methods for stain and plaque removal. Access to crowded teeth, grooves and involved furcation areas are easily obtainable with less operator fatigue. The APAD slurry produces different root surface abrasiveness, depending on the method of use. Extended maintenance periods of exposed root surface using the APAD can result in an enormous loss of root structure. To avoid permanent damage of the root, the device should be used with overlapping strokes and root exposure to the APAD slurry should be minimized. The device can be used for total cementum removal with less operator fatigue and more reproducibility than with hand instruments, leaving smooth and clean surfaces. In addition, the device may be a valuable tool in the detoxification of root surfaces during periodontal surgery.

  12. Exaggerated abrasion/erosion of human dental enamel surfaces

    DEFF Research Database (Denmark)

    Westergaard, J; Moe, D; Pallesen, Ulla

    1993-01-01

    An atypical, rapidly proceeding abrasion/erosion of the labial enamel surfaces of the maxillary and mandibular incisors and canines in a 27-yr-old man is reported. Ultrastructural examination of a replica of the teeth showed a practically structureless enamel surface both at the initial examinati...

  13. Effects of enamel abrasion, salivary pellicle, and measurement angle on the optical assessment of dental erosion

    OpenAIRE

    Lussi, Adrian; Bossen, Anke; Höschele, Christoph; Beyeler, Barbara; Megert, Brigitte; Meier, Christoph; Rakhmatullina, Ekaterina

    2012-01-01

    The present study assessed the effects of abrasion, salivary proteins, and measurement angle on the quantification of early dental erosion by the analysis of reflection intensities from enamel. Enamel from 184 caries-free human molars was used for in vitro erosion in citric acid (pH 3.6). Abrasion of the eroded enamel resulted in a 6% to 14% increase in the specular reflection intensity compared to only eroded enamel, and the reflection increase depended on the erosion degree. Nevertheless, m...

  14. Erosion and abrasion on dental structures undergoing at-home bleaching

    Directory of Open Access Journals (Sweden)

    Tarquinio SBC

    2011-07-01

    Full Text Available Flávio Fernando Demarco1, Sônia Saeger Meireles2, Hugo Ramalho Sarmento1, Raquel Venâncio Fernandes Dantas1, Tatiana Botero3, Sandra Beatriz Chaves Tarquinio11Graduate Program in Dentistry, School of Dentistry, Federal University of Pelotas, Brazil; 2Department of Operative Dentistry, Federal University of Paraíba, Brazil; 3Cariology, Restorative Science, and Endodontics Department, School of Dentistry, University of Michigan, MI, USAAbstract: This review investigates erosion and abrasion in dental structures undergoing at-home bleaching. Dental erosion is a multifactorial condition that may be idiopathic or caused by a known acid source. Some bleaching agents have a pH lower than the critical level, which can cause changes in the enamel mineral content. Investigations have shown that at-home tooth bleaching with low concentrations of hydrogen or carbamide peroxide have no significant damaging effects on enamel and dentin surface properties. Most studies where erosion was observed were in vitro. Even though the treatment may cause side effects like sensitivity and gingival irritation, these usually disappear at the end of treatment. Considering the literature reviewed, we conclude that tooth bleaching agents based on hydrogen or carbamide peroxide have no clinically significant influence on enamel/dentin mineral loss caused by erosion or abrasion. Furthermore, the treatment is tolerable and safe, and any adverse effects can be easily reversed and controlled.Keywords: peroxide, tooth bleaching, enamel, dentin, erosion, abrasion

  15. Hydrothermal treatment for TiN as abrasion resistant dental implant coating and its fibroblast response

    Energy Technology Data Exchange (ETDEWEB)

    Shi, Xingling, E-mail: shixingling1985@hotmail.com [School of Material Science and Engineering, Jiangsu University of Science and Technology, Zhenjiang 212003 (China); Department of Biomaterials, Faculty of Dental Science, Kyushu University, Fukuoka 812-8582 (Japan); Jiangsu Provincial Key Laboratory for Interventional Medical Devices, Huaiyin Institute of Technology, Huaian 223003 (China); Xu, Lingli [School of Material Science and Engineering, Jiangsu University of Science and Technology, Zhenjiang 212003 (China); Munar, Melvin L.; Ishikawa, Kunio [Department of Biomaterials, Faculty of Dental Science, Kyushu University, Fukuoka 812-8582 (Japan)

    2015-04-01

    Dental implant made of pure titanium (Ti) is prone to scratch and abrasion during routine oral hygiene procedures. This results an increase in surface roughness and therefore, facilitates the adhesion of bacteria. In severe cases, this could lead to peri-implantitis. To overcome this problem, surface modification of Ti is necessary to improve its abrasion resistance. Besides, a strong implant–gingiva interface should also be guaranteed to prevent the adhesion of bacteria. In this study, titanium nitride (TiN) coating was first prepared with gas nitriding to increase surface hardness of pure the substrate. Then, the TiN was hydrothermally treated in CaCl{sub 2} solution in order to improve its soft tissue biocompatibility. The effect of hydrothermal treatment temperature on surface properties of TiN was investigated and its biocompatibility was assessed in vitro using NIH3T3 fibroblast cell. It was determined that 120 °C was the critical temperature for the hydrothermal treatment condition. Treatment below 120 °C could incorporate Ca into TiN surface, oxidize TiN surface partially and then improve the wettability while preserving its morphology and hardness. Fibroblast cell attachment and proliferation were improved and cell spreading was enhanced on hydrothermally treated specimens compared with untreated ones. Improved wettability, Ca incorporation and negative surface due to interstitial N were believed to be the main reasons. Hydrothermal treatment is expected to make TiN a promising dental implant coating with excellent abrasion resistance and good soft tissue affinity. - Highlights: • Ca was incorporated into TiN surface while not sacrificing its hardness. • Interstitial N due to oxidation promoted Ca adsorption and cell adhesion. • Hydrothermal treatment makes TiN a promising coating for dental implant.

  16. Potential Use of Abrasive Air-Propelled Agricultural Residues for Weed Control

    Science.gov (United States)

    A new postemergence weed control tactic is proposed for organic production systems that results in plant abrasion and death upon assault from abrasive grits propelled by compressed air. Grit derived from granulated walnut shells was delivered by a sand blaster at 517 kPa at distances of 30 to 60 cm ...

  17. Effects of enamel abrasion, salivary pellicle, and measurement angle on the optical assessment of dental erosion

    Science.gov (United States)

    Lussi, Adrian; Bossen, Anke; Höschele, Christoph; Beyeler, Barbara; Megert, Brigitte; Meier, Christoph; Rakhmatullina, Ekaterina

    2012-09-01

    The present study assessed the effects of abrasion, salivary proteins, and measurement angle on the quantification of early dental erosion by the analysis of reflection intensities from enamel. Enamel from 184 caries-free human molars was used for in vitro erosion in citric acid (pH 3.6). Abrasion of the eroded enamel resulted in a 6% to 14% increase in the specular reflection intensity compared to only eroded enamel, and the reflection increase depended on the erosion degree. Nevertheless, monitoring of early erosion by reflection analysis was possible even in the abraded eroded teeth. The presence of the salivary pellicle induced up to 22% higher reflection intensities due to the smoothing of the eroded enamel by the adhered proteins. However, this measurement artifact could be significantly minimized (pmeasurement angles from 45 to 60 deg did not improve the sensitivity of the analysis at late erosion stages. The applicability of the method for monitoring the remineralization of eroded enamel remained unclear in a demineralization/remineralization cycling model of early dental erosion in vitro.

  18. Effects of enamel abrasion, salivary pellicle, and measurement angle on the optical assessment of dental erosion.

    Science.gov (United States)

    Lussi, Adrian; Bossen, Anke; Höschele, Christoph; Beyeler, Barbara; Megert, Brigitte; Meier, Christoph; Rakhmatullina, Ekaterina

    2012-09-01

    The present study assessed the effects of abrasion, salivary proteins, and measurement angle on the quantification of early dental erosion by the analysis of reflection intensities from enamel. Enamel from 184 caries-free human molars was used for in vitro erosion in citric acid (pH 3.6). Abrasion of the eroded enamel resulted in a 6% to 14% increase in the specular reflection intensity compared to only eroded enamel, and the reflection increase depended on the erosion degree. Nevertheless, monitoring of early erosion by reflection analysis was possible even in the abraded eroded teeth. The presence of the salivary pellicle induced up to 22% higher reflection intensities due to the smoothing of the eroded enamel by the adhered proteins. However, this measurement artifact could be significantly minimized (pmeasurement angles from 45 to 60 deg did not improve the sensitivity of the analysis at late erosion stages. The applicability of the method for monitoring the remineralization of eroded enamel remained unclear in a demineralization/remineralization cycling model of early dental erosion in vitro.

  19. Comparing the Air Abrasion Cutting Efficacy of Dentine Using a Fluoride-Containing Bioactive Glass versus an Alumina Abrasive: An In Vitro Study.

    Science.gov (United States)

    Tan, Melissa H X; Hill, Robert G; Anderson, Paul

    2015-01-01

    Air abrasion as a caries removal technique is less aggressive than conventional techniques and is compatible for use with adhesive restorative materials. Alumina, while being currently the most common abrasive used for cutting, has controversial health and safety issues and no remineralisation properties. The alternative, a bioactive glass, 45S5, has the advantage of promoting hard tissue remineralisation. However, 45S5 is slow as a cutting abrasive and lacks fluoride in its formulation. The aim of this study was to compare the cutting efficacy of dentine using a customised fluoride-containing bioactive glass Na0SR (38-80 μm) versus the conventional alumina abrasive (29 μm) in an air abrasion set-up. Fluoride was incorporated into Na0SR to enhance its remineralisation properties while strontium was included to increase its radiopacity. Powder outflow rate was recorded prior to the cutting tests. Principal air abrasion cutting tests were carried out on pristine ivory dentine. The abrasion depths were quantified and compared using X-ray microtomography. Na0SR was found to create deeper cavities than alumina (p cutting efficiency. In conclusion, Na0SR was more efficacious than alumina for air abrasion cutting of dentine.

  20. Comparing the Air Abrasion Cutting Efficacy of Dentine Using a Fluoride-Containing Bioactive Glass versus an Alumina Abrasive: An In Vitro Study

    Directory of Open Access Journals (Sweden)

    Melissa H. X. Tan

    2015-01-01

    Full Text Available Air abrasion as a caries removal technique is less aggressive than conventional techniques and is compatible for use with adhesive restorative materials. Alumina, while being currently the most common abrasive used for cutting, has controversial health and safety issues and no remineralisation properties. The alternative, a bioactive glass, 45S5, has the advantage of promoting hard tissue remineralisation. However, 45S5 is slow as a cutting abrasive and lacks fluoride in its formulation. The aim of this study was to compare the cutting efficacy of dentine using a customised fluoride-containing bioactive glass Na0SR (38–80 μm versus the conventional alumina abrasive (29 μm in an air abrasion set-up. Fluoride was incorporated into Na0SR to enhance its remineralisation properties while strontium was included to increase its radiopacity. Powder outflow rate was recorded prior to the cutting tests. Principal air abrasion cutting tests were carried out on pristine ivory dentine. The abrasion depths were quantified and compared using X-ray microtomography. Na0SR was found to create deeper cavities than alumina (p<0.05 despite its lower powder outflow rate and predictably reduced hardness. The sharper edges of the Na0SR glass particles might improve the cutting efficiency. In conclusion, Na0SR was more efficacious than alumina for air abrasion cutting of dentine.

  1. Dental Compressed Air Systems.

    Science.gov (United States)

    1992-03-01

    compressor ex- cept that the piston rings are made of a low friction material (usually a Teflon- composite ) The piston walls are oil-less and all friction... descal - ing. The water-cooled models are smaller, more efficient, and cause less heating of room air. Water-cooled aftercoolers must have an...dry to a dew point of -400C (-400 F). It has high adsorption capacity. (b) Silica Gel , which must be protected from liquid (usually by a layer of

  2. Toothpastes containing abrasive and chemical whitening agents: efficacy in reducing extrinsic dental staining.

    Science.gov (United States)

    Soares, Cristina Neves Girao Salgado; Amaral, Flavia Lucisano Botelho do; Mesquita, Marcelo Ferraz; Franca, Fabiana Mantovani Gomes; Basting, Roberta Tarkany; Turssi, Cecilia Pedroso

    2015-01-01

    This in vitro study evaluated the efficacy of toothpastes containing abrasive and chemical whitening agents in reducing the extrinsic discoloration of dental enamel. Sixty slabs of dentin from human teeth were sealed so that only the enamel surface was exposed. The enamel surfaces were photographed for initial color assessment. Staining was performed by immersing the dental slabs in 0.2% chlorhexidine solution for 2 minutes and then in black tea for 60 minutes. This process was repeated 15 times. Photographs were taken at the end of the staining process, and the slabs were divided into 5 groups (n = 12), 3 to be brushed with toothpastes containing chemical whitening agents (2 containing phosphate salts and 1 containing phosphate salts plus hydrogen peroxide) and 2 to represent control groups (ordinary/nonwhitening toothpaste and distilled water). The dental slabs were subjected to mechanical toothbrushing with toothpaste slurry or distilled water, according to each group's specifications. After brushing, more photographs were taken for color analysis. The results showed a significant reduction in luminosity after the staining process in addition to an increase in the colors red and yellow (P toothpastes and the changes found in slabs brushed with ordinary toothpaste. The whitening toothpastes did not outperform an ordinary toothpaste in the removal of extrinsic staining.

  3. The effect of abrasive blasting on the strength of a joint between dental porcelain and metal base.

    Science.gov (United States)

    Pietnicki, Krzysztof; Wołowiec, Emilia; Klimek, Leszek

    2014-01-01

    This paper presents the effect of selected parameters of abrasive blasting on the strength of a joint between dental porcelain and metal base. Experiments were conducted for different grain sizes of abrasive material and different blasting angles, with a constant blasting pressure. InLine dental porcelain was fused on samples of cobalt-chromium alloy following abrasive blasting; they were subsequently subjected to shearing forces on a testing machine. The fractures were observed under an electron scanning microscope in order to determine the character and course of fracturing. Strength tests showed that the grain size of abrasive material was a parameter with the greatest effect on the strength. The best effects were achieved for samples subjected to abrasive blasting with material with grain size of 110 μm. No statistically significant differences were found for the strength of samples worked at different angles. The results of the fractographic examinations have shown that in all the samples, fracturing occurred mainly along the porcelain-metal boundary, with few cases of fracturing through porcelain.

  4. Potential of Air-Propelled Abrasives for Selective Weed Control

    Science.gov (United States)

    Novel forms of selective weed control are needed by many types of growers, but especially organic growers who are restricted from using synthetic herbicides. Abrasive grit made from corn cobs was expelled from a sand blaster at 517 kPa pressure and aimed at seedlings of common lambsquarters and corn...

  5. Hybrid layer thickness and morphology: Influence of cavity preparation with air abrasion.

    Science.gov (United States)

    Barceleiro, Marcos Oliveira; de Mello, Jose Benedicto; Porto, Celso Luis de Angelis; Dias, Katia Regina Hostilio Cervantes; de Miranda, Mauro Sayao

    2011-01-01

    Dentinal surfaces prepared with air abrasion have considerably different characteristics from those prepared with conventional instruments. Different hybrid layer morphology and thickness occur, which can result in differences in the quality of restorations placed on dentinal surfaces prepared with a diamond bur compared to surfaces prepared using air abrasion. The objective of this study was to compare the hybrid layer thickness and morphology formed utilizing Scotchbond Multi-Purpose Plus (SBMP) on dentin prepared with a diamond bur in a high-speed handpiece and on dentin prepared using air abrasion. Flat dentin surfaces obtained from five human teeth were prepared using each method, then treated with the dentin adhesive system according to manufacturer's instructions. After a layer of composite was applied, specimens were sectioned, flattened, polished, and prepared for scanning electron microscopy. Ten different measurements of hybrid layer thickness were obtained along the bonded surface in each specimen. SBMP produced a 3.43 ± 0.75 µm hybrid layer in dentin prepared with diamond bur. This hybrid layer was regular and found consistently. In the air abrasion group, SBMP produced a 4.94 ± 1.28 µm hybrid layer, which was regular and found consistently. Statistical ANOVA (P = 0.05) indicated that there was a statistically significant difference between the groups. These data indicate that the air abrasion, within the parameters used in this study, provides a thick hybrid layer formation.

  6. An in vitro evaluation of selective demineralised enamel removal using bio-active glass air abrasion.

    Science.gov (United States)

    Banerjee, Avijit; Pabari, Hiten; Paolinelis, George; Thompson, Ian D; Watson, Timothy F

    2011-12-01

    Unnecessary over-preparation of carious enamel often occurs clinically during operative caries management. The working hypothesis to be investigated in this study is the potential for bio-active glass air abrasion to remove selectively only demineralised enamel in artificial enamel lesions when compared to equivalent alumina air abrasion, so potentially minimising cavity over-preparation. Bisected artificial, paired smooth surface enamel lesions on ethics-approved, extracted sound human molars were created and subsequently air abraded with 27 μm alumina (n = 19) and bio-active glass (n = 19). The difference between pre-operative lesion boundary and post-operative cavity margin was calculated following optical confocal fluorescent assessment of the lesion boundary. Data indicated mean% over-preparation (sound enamel removal) of 176% with alumina and 15.2% for bio-active glass (p = 0.005). Bio-active glass abrasion removed completely the demineralised enamel from artificial lesions with clinically insignificant over-preparation of sound tissue, indicating technique selectivity towards grossly demineralised enamel. Alumina air abrasion resulted in substantial enamel removal in both sound and demineralised tissues indicating the operator selectivity required to use the techniques effectively in clinical practice.

  7. Air-propelled abrasive grit for postemergence in-row weed control in field corn

    Science.gov (United States)

    Organic growers need additional tools for weed control. A new technique involving abrasive grit propelled by compressed air was tested in field plots. Grit derived from corn cobs was directed at seedlings of summer annual weeds growing at the bases of corn plants when the corn was at differing early...

  8. Adhesive interfaces of enamel and dentin prepared by air-abrasion at different distances

    Energy Technology Data Exchange (ETDEWEB)

    Chinelatti, Michelle Alexandra [School of Dentistry of Ribeirao Preto/University of Sao Paulo, Department of Restorative Dentistry, Ribeirao Preto-SP (Brazil)]. E-mail: michinelatti@gmail.com; Andreolli do Amaral, Thais Helena [School of Dentistry of Ribeirao Preto/University of Sao Paulo, Department of Restorative Dentistry, Ribeirao Preto-SP (Brazil); Borsatto, Maria Cristina [School of Dentistry of Ribeirao Preto/University of Sao Paulo, Department of Pediatric Dentistry, Ribeirao Preto-SP (Brazil); Palma-Dibb, Regina Guenka [School of Dentistry of Ribeirao Preto/University of Sao Paulo, Department of Restorative Dentistry, Ribeirao Preto-SP (Brazil); Corona, Silmara Aparecida Milori [School of Dentistry of Ribeirao Preto/University of Sao Paulo, Department of Restorative Dentistry, Ribeirao Preto-SP (Brazil)

    2007-03-30

    The purpose of this study was to analyse, by scanning electron microscopy (SEM), the morphology of enamel and dentin/adhesive interfaces in cavities prepared by air-abrasion at different working distances. Thirty sound third human molars were selected and, on both their buccal and lingual surfaces, class V cavities were prepared by air-abrasion, at 2-, 4-, 6-, 8- and 10-mm working distances, or high-speed bur (control group). After preparation, all cavities were etched with 35% phosphoric acid gel and restored with Single Bond/Filtek Z-250. Buccal and lingual surfaces were separated and restorations sectioned in a buccolingual direction, providing two sections of each cavity, which were analysed by scanning electron microscopy. It was observed that the distances of 6 and 8 mm promoted more homogeneous dentin/adhesive interfaces, with tags formation, and more uniform for enamel, which were similar to the control group. It may be concluded that the air-abrasion working distance can influence the morphology of enamel and dentin/adhesive interfaces, and the intermediate distances provided better adhesive interfaces.

  9. Evaluation of the effects of enameloplasty and air abrasion on sealant micro-leakage.

    Directory of Open Access Journals (Sweden)

    Aliasghar Soleymani

    2014-12-01

    Full Text Available Micro-leakage, one of the major reasons for recurrent decays, may lead to uncontrollable flow of liquids, pulp inflammation and peri-apical pathology. The purpose of this in vitro study was to evaluate micro-leakage of pit and fissure sealants after using three different pit and fissure preparation techniques: 1 acid etching, 2 fissure enameloplasty and acid etching, and 3 air abrasion and acid etching.Sixty-nine extracted sound molars and premolars were randomly divided into three groups (23 samples in each group. Teeth were prepared using one of three occlusal surface treatments. Then the sealant was applied on the occlusal fissures of all teeth. The teeth were thermocycled and stored in normal saline. All teeth were sealed apically and coated with nail varnish and then were immersed in a 2% solution of methylen blue. Two buccolingual sections were made. The surfaces were scored 0 to 3 for the extent of micro-leakage using a stereomicroscope. Data were analyzed by Kruskal- wallis and Dunn procedure.Enameloplasty and acid etching were significantly different regarding micro-leakage (P= 0.016, but no significant difference in micro-leakage was observed between air abrasion and the other methods.Enameloplasty followed by acid etching produced significantly less micro-leakage than the acid etching technique. Air abrasion acid etching was better than the acid etching technique in reducing micro-leakage too.

  10. Bio-active glass air-abrasion has the potential to remove resin composite restorative material selectively

    Science.gov (United States)

    Milly, Hussam; Andiappan, Manoharan; Thompson, Ian; Banerjee, Avijit

    2014-06-01

    The aims of this study were to assess: (a) the chemistry, morphology and bioactivity of bio-active glass (BAG) air-abrasive powder, (b) the effect of three air-abrasion operating parameters: air pressure, powder flow rate (PFR) and the abrasive powder itself, on the selective removal of resin composite and (c) the required “time taken”. BAG abrasive particles were characterised using scanning electron microscopy-energy dispersive X-ray spectrometry (SEM-EDX) and Fourier-transform infrared spectroscopy (FTIR). Standardised resin composite restorations created within an enamel analogue block (Macor™) in vitro, were removed using air-abrasion undersimulated clinical conditions. 90 standardised cavities were scanned before and after resin composite removal using laser profilometry and the volume of the resulting 3D images calculated. Multilevel linear model was used to identify the significant factors affecting Macor™ removal. BAG powder removed resin composite more selectively than conventional air-abrasion alumina powder using the same operating parameters (p resin composite particularly under specific operating parameters, and therefore may be recommended clinically as a method of preserving sound enamel structure when repairing and removing defective resin composite restorations.

  11. Bio-active glass air-abrasion has the potential to remove resin composite restorative material selectively

    Energy Technology Data Exchange (ETDEWEB)

    Milly, Hussam [Biomaterials, Biomimetics and Biophotonics Research Group, Kings College London Dental Institute at Guy' s Hospital, King' s Health Partners, London (United Kingdom); Andiappan, Manoharan [Unit of Dental Public Health, Kings College London Dental Institute at Guy' s Hospital, King' s Health Partners, London (United Kingdom); Thompson, Ian [Biomaterials, Biomimetics and Biophotonics Research Group, Kings College London Dental Institute at Guy' s Hospital, King' s Health Partners, London (United Kingdom); Banerjee, Avijit, E-mail: avijit.banerjee@kcl.ac.uk [Biomaterials, Biomimetics and Biophotonics Research Group, Kings College London Dental Institute at Guy' s Hospital, King' s Health Partners, London (United Kingdom); Unit of Conservative Dentistry, King' s College London Dental Institute at Guy' s Hospital, King' s Health Partners, London (United Kingdom)

    2014-06-01

    The aims of this study were to assess: (a) the chemistry, morphology and bioactivity of bio-active glass (BAG) air-abrasive powder, (b) the effect of three air-abrasion operating parameters: air pressure, powder flow rate (PFR) and the abrasive powder itself, on the selective removal of resin composite and (c) the required “time taken”. BAG abrasive particles were characterised using scanning electron microscopy-energy dispersive X-ray spectrometry (SEM-EDX) and Fourier-transform infrared spectroscopy (FTIR). Standardised resin composite restorations created within an enamel analogue block (Macor™) in vitro, were removed using air-abrasion undersimulated clinical conditions. 90 standardised cavities were scanned before and after resin composite removal using laser profilometry and the volume of the resulting 3D images calculated. Multilevel linear model was used to identify the significant factors affecting Macor™ removal. BAG powder removed resin composite more selectively than conventional air-abrasion alumina powder using the same operating parameters (p < 0.001) and the effect of altering the unit's operating parameters was significant (p < 0.001). In conclusion, BAG powder is more efficient than alumina in the selective removal of resin composite particularly under specific operating parameters, and therefore may be recommended clinically as a method of preserving sound enamel structure when repairing and removing defective resin composite restorations.

  12. Effect of Bioactive Glass air Abrasion on Shear Bond Strength of Two Adhesive Resins to Decalcified Enamel

    Science.gov (United States)

    Eshghi, Alireza; Khoroushi, Maryam; Rezvani, Alireza

    2014-01-01

    Objective: Bioactive glass air abrasion is a conservative technique to remove initial decalcified tissue and caries. This study examined the shear bond strength of composite resin to sound and decalcified enamel air-abraded by bioactive glass (BAG) or alumina using etch-and-rinse and self-etch adhesives. Materials and Methods: Forty-eight permanent molars were root-amputated and sectioned mesiodistally. The obtained 96 specimens were mounted in acrylic resin; the buccal and lingual surfaces remained exposed. A demineralizing solution was used to decalcify half the specimens. Both sound and decalcified specimens were divided into two groups of alumina and bioactive glass air abrasion. In each group, the specimens were subdivided into two subgroups of Clearfil SE Bond or OptiBond FL adhesives (n=12). Composite resin cylinders were bonded on enamel surfaces cured and underwent thermocycling. The specimens were tested for shear bond strength. Data were analyzed using SPSS 16.0 and three-way ANOVA (α=0.05). Similar to the experimental groups, the enamel surface of one specimen underwent SEM evaluation. Results: No significant differences were observed in composite resin bond strength subsequent to alumina or bioactive glass air abrasion preparation techniques (P=0.987). There were no statistically significant differences between the bond strength of etch-and-rinse and self-etch adhesive groups (P=1). Also, decalcified or intact enamel groups had no significant difference (P=0.918). However, SEM analysis showed much less enamel irregularities with BAG air abrasion compared to alumina air abrasion. Conclusion: Under the limitations of this study, preparation of both intact and decalcified enamel surfaces with bioactive glass air abrasion results in similar bond strength of composite resin in comparison with alumina air abrasion using etch-&-rinse or self-etch adhesives. PMID:25628694

  13. Effect of Bioactive Glass air Abrasion on Shear Bond Strength of Two Adhesive Resins to Decalcified Enamel.

    Directory of Open Access Journals (Sweden)

    Alireza Eshghi

    2014-12-01

    Full Text Available Bioactive glass air abrasion is a conservative technique to remove initial decalcified tissue and caries. This study examined the shear bond strength of composite resin to sound and decalcified enamel air-abraded by bioactive glass (BAG or alumina using etch-and-rinse and self-etch adhesives.Forty-eight permanent molars were root-amputated and sectioned mesiodistally. The obtained 96 specimens were mounted in acrylic resin; the buccal and lingual surfaces remained exposed. A demineralizing solution was used to decalcify half the specimens. Both sound and decalcified specimens were divided into two groups of alumina and bioactive glass air abrasion. In each group, the specimens were subdivided into two subgroups of Clearfil SE Bond or OptiBond FL adhesives (n=12. Composite resin cylinders were bonded on enamel surfaces cured and underwent thermocycling. The specimens were tested for shear bond strength. Data were analyzed using SPSS 16.0 and three-way ANOVA (α=0.05. Similar to the experimental groups, the enamel surface of one specimen underwent SEM evaluation.No significant differences were observed in composite resin bond strength subsequent to alumina or bioactive glass air abrasion preparation techniques (P=0.987. There were no statistically significant differences between the bond strength of etch-and-rinse and self-etch adhesive groups (P=1. Also, decalcified or intact enamel groups had no significant difference (P=0.918. However, SEM analysis showed much less enamel irregularities with BAG air abrasion compared to alumina air abrasion.Under the limitations of this study, preparation of both intact and decalcified enamel surfaces with bioactive glass air abrasion results in similar bond strength of composite resin in comparison with alumina air abrasion using etch-&-rinse or self-etch adhesives.

  14. 21 CFR 872.6010 - Abrasive device and accessories.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6010 Abrasive device and accessories... disk, guard for an abrasive disk, abrasive point, polishing agent strip, and polishing wheel....

  15. In vitro toothbrushing abrasion of dental resin composites: packable, microhybrid, nanohybrid and microfilled materials

    Directory of Open Access Journals (Sweden)

    Rafael Ratto de Moraes

    2008-06-01

    Full Text Available This study evaluated weight loss and surface roughening after toothbrushing of different resin composites: one packable (Solitaire 2, Heraeus Kulzer, one microhybrid (Charisma, Heraeus Kulzer, one nanohybrid (Simile, Pentron and one microfilled (Durafill VS, Heraeus Kulzer. Cylindrical specimens (n = 20 were prepared. Half of the samples were submitted to 60,000 strokes, at 4 Hz, with a dentifrice-water slurry. Control samples (n = 10 remained stored at 37°C. Pre- and post-abrasion parameters for weight (mg and surface roughness (Ra, µm were determined on an analytical balance and a surface profilometer. Data were separately submitted to Repeated Measures ANOVA and Tukey's test (a = 0.05. Percentages of weight loss were analyzed by ANOVA and Tukey's test (a = 0.05. The relationship between both evaluations was assessed by Pearson's test (a = 0.05. The means (% for weight loss (standard deviation were 0.65(0.2, 0.93(0.2, 1.25(0.6 and 1.25(0.4 for Simile, Durafill, Charisma and Solitaire, respectively. Baseline roughness means ranged from 0.065(0.01, 0.071(0.01, 0.066(0.02 and 0.074(0.01 for Simile, Durafill, Charisma and Solitaire, respectively, to 0.105(0.04, 0.117(0.03, 0.161(0.03 and 0.214(0.07 after testing. The composites with larger fillers presented higher weight loss and roughening than the finer materials (p < 0.05. For both evaluations, control specimens showed no significant alteration. No significant relationship between loss of weight and roughness alteration was detected (r = 0.322, p = 0.429.

  16. Effect of sodium bicarbonate air abrasive polishing on resistance to sliding during tooth alignment and leveling: An in vitro study

    Directory of Open Access Journals (Sweden)

    Jorge C. B. L. Filho

    2012-01-01

    Full Text Available Objective: The aim of this in vitro study was to evaluate the Resistance to Sliding (RS provided by metallic brackets and 3 types of orthodontic wires (TMA, SS and NiTi, before and after the use of sodium bicarbonate airborne particle abrasion, in an experimental model with 3 non leveled brackets. Materials and Methods: The bicarbonate airborne abrasion was applied perpendicularly to the bracket slots at a distance of 2 mm, for 5 seconds (T2 and 10 seconds (T3 on each bracket slot. In a universal testing machine, the wires were pulled through a set of 3 non leveled brackets at a cross head speed of 50 mm/min for a distance of 10 mm, and static and kinetic friction readings were registered at T1 (no airborne abrasion, T2 and T3. Results: For all tested wires, a significant RS increase between T1 and T3 (P<0.001 was seen. For SS and TMA wires, there was a statistically significant RS increase between T1 and T2 (P<0.001. Between T2 and T3, RS increase was significant for TMA (P<0.001 and NiTiwires (P<0.05. Conclusions: Sodium bicarbonate air abrasive polishing during orthodontic treatment is not recommended, once this procedure promoted a significant RS increase between the metallic brackets and all the three types of wires tested.

  17. Comparison of shear bond strength and surface structure between conventional acid etching and air-abrasion of human enamel.

    Science.gov (United States)

    Olsen, M E; Bishara, S E; Damon, P; Jakobsen, J R

    1997-11-01

    Recently, air-abrasion technology has been examined for potential applications within dentistry, including the field of orthodontics. The purpose of this study was to compare the traditional acid-etch technique with an air-abrasion surface preparation technique, with two different sizes of abrading particles. The following parameters were evaluated: (a) shear bond strength, (b) bond failure location, and (c) enamel surface preparation, as viewed through a scanning electron microscope. Sixty extracted human third molars were pumiced and divided into three groups of 20. The first group was etched with a 37% phosphoric acid gel for 30 seconds, rinsed for 30 seconds, and dried for 20 seconds. The second and third groups were air-abraded with (a) a 50 microm particle and (b) a 90 microm particle of aluminum oxide, with the Micro-etcher microabrasion machine (Danville Engineering Inc.). All three groups had molar stainless steel orthodontic brackets bonded to the buccal surface of each tooth with Transbond XT bonding system (3M Unitek). A Zwick Universal Testing Machine (Calitek Corp.) was used to determine shear bond strengths. The analysis of variance was used to compare the three groups. The Adhesive Remnant Index (ARI) was used to evaluate the residual adhesive on the enamel after bracket removal. The chi square test was used to evaluate differences in the ARI scores among the groups. The significance for all tests was predetermined at p shear bond strength among the three groups (p = 0.0001). The Duncan Multiple Range test showed a significant decrease in shear bond strength in the air-abraded groups. The chi square test revealed significant differences among the ARI scores of the acid-etched group and the air-abraded groups (chi(2) = 0.0001), indicating no adhesive remained on the enamel surface after debonding when air-abrasion was used. In conclusion, the current findings indicate that enamel surface preparation using air-abrasion results in a significant lower

  18. In vitro evaluation of human dental enamel surface roughness bleached with 35% carbamide peroxide and submitted to abrasive dentifrice brushing.

    Science.gov (United States)

    Worschech, Claudia Cia; Rodrigues, José Augusto; Martins, Luis Roberto Marcondes; Ambrosano, Gláucia Maria Bovi

    2003-01-01

    The aim of this in vitro study was to evaluate the surface roughness of human enamel bleached with 35% carbamide peroxide at different times and submitted to different superficial cleaning treatments: G1 - not brushed; G2 - brushed with fluoride abrasive dentifrice; G3 - brushed with a non-fluoride abrasive dentifrice; G4 - brushed without dentifrice. Sixty fragments of human molar teeth with 4 x 4 mm were obtained using a diamond disc. The specimens were polished with sandpaper and abrasive pastes. A perfilometer was used to measure roughness average (Ra) values of the initial surface roughness and at each 7-day-interval after the beginning of treatment. The bleaching was performed on the surface of the fragments for 1 hour a week, and the surface cleaning treatment for 3 minutes daily. The samples were stored in individual receptacles with artificial saliva. Analysis of variance and the Tukey test revealed significant differences in surface roughness values for G2 and G3, which showed an increase in roughness over time; G1 and G4 showed no significant roughness differences. The bleaching with 35% carbamide peroxide did not alter the enamel surface roughness, but when the bleaching treatment was performed combined with brushing with abrasive dentifrices, there was a significant increase in roughness values.

  19. In vitro evaluation of human dental enamel surface roughness bleached with 35% carbamide peroxide and submitted to abrasive dentifrice brushing

    Directory of Open Access Journals (Sweden)

    Worschech Claudia Cia

    2003-01-01

    Full Text Available The aim of this in vitro study was to evaluate the surface roughness of human enamel bleached with 35% carbamide peroxide at different times and submitted to different superficial cleaning treatments: G1 - not brushed; G2 - brushed with fluoride abrasive dentifrice; G3 - brushed with a non-fluoride abrasive dentifrice; G4 - brushed without dentifrice. Sixty fragments of human molar teeth with 4 x 4 mm were obtained using a diamond disc. The specimens were polished with sandpaper and abrasive pastes. A perfilometer was used to measure roughness average (Ra values of the initial surface roughness and at each 7-day-interval after the beginning of treatment. The bleaching was performed on the surface of the fragments for 1 hour a week, and the surface cleaning treatment for 3 minutes daily. The samples were stored in individual receptacles with artificial saliva. Analysis of variance and the Tukey test revealed significant differences in surface roughness values for G2 and G3, which showed an increase in roughness over time; G1 and G4 showed no significant roughness differences. The bleaching with 35% carbamide peroxide did not alter the enamel surface roughness, but when the bleaching treatment was performed combined with brushing with abrasive dentifrices, there was a significant increase in roughness values.

  20. In vitro comparative bond strength of contemporary self-adhesive resin cements to zirconium oxide ceramic with and without air-particle abrasion.

    Science.gov (United States)

    Blatz, Markus B; Phark, Jin-Ho; Ozer, Fusun; Mante, Francis K; Saleh, Najeed; Bergler, Michael; Sadan, Avishai

    2010-04-01

    This study compared shear bond strengths of six self-adhesive resin cements to zirconium oxide ceramic with and without air-particle abrasion. One hundred twenty zirconia samples were air-abraded (group SB; n = 60) or left untreated (group NO). Composite cylinders were bonded to the zirconia samples with either BisCem (BC), Maxcem (MC), G-Cem (GC), RelyX Unicem Clicker (RUC), RelyX Unicem Applicator (RUA), or Clearfil SA Cement (CSA). Shear bond strength was tested after thermocycling, and data were analyzed with analysis of variance and Holm-Sidak pairwise comparisons. Without abrasion, RUA (8.0 MPa), GC (7.9 MPa), and CSA (7.6 MPa) revealed significantly higher bond strengths than the other cements. Air-particle abrasion increased bond strengths for all test cements (p MDP/4-META) were superior to other compositions.

  1. Elimination of microorganisms from dental operatory compressed air.

    Science.gov (United States)

    De Ciccio, A; Chan, E C

    1998-01-01

    Compressed air is used to power high-speed handpieces, as well as to dry and clean surfaces in the oral cavity during patient treatment, in all dental operatories. The compressed air used in the dental operatories located in large institutions such as universities or hospitals is generally obtained from a central source, and is produced by continually running compressors. In operatories located in private practice settings, compressed air is obtained from small on-site air compressors, which may be run less frequently. A survey was made of operatories in the Montreal area to determine the microbial load of the compressed air produced by air compressors. An air sampler was used to collect compressed air and impinge it on a rotating agar medium surface. Compared to the air produced from compressors in constant use, the air collected from compressors that ran intermittently had a very high microbial load. The efficacy of an apparatus designed to sterilize the contaminated air produced by small, on-site compressors was tested. Called a Purilair, this device heats every particle of inflowing compressed air to 250 degrees C and then forces it through a fine-pore ceramic filter. In three private practice operatories, an in-line Purilair effectively sterilized the air being delivered by small compressors. The same result was obtained in the laboratory when lyophilized spores and cells of Bacillus stearothermophilus and conidia of Penicillium notatum and Aspergillus niger were sprayed into the intake line of the apparatus.

  2. Air quality modelling as a tool used in selecting technological alternatives for developing a new abrasive facility

    Directory of Open Access Journals (Sweden)

    Radu Mihăiescu

    2011-08-01

    Full Text Available Production of abrasive compounds employs the use of various organic materials as adhesivesor as conditioners. During the baking process, a significant amount of air pollutant substances, includingvarious forms of organic compounds are emitted in the atmosphere. Selecting the most suitabletechnological process is a procedure that involves a cost benefit analysis as well as procedures forcomplying with BAT requirements (best available techniques. Assessing the resulting environmentquality in the vicinity of a new facility is also important, IPPC Directive clearly specifies that a new facilitymust not induce changes of the quality of the environment. This is highly dependent on localmeteorological and topographical conditions. The ISCST3 model was applied to assess the atmosphericdispersions associated with several potential technological designs, and compare their impacts on theenvironment.

  3. Selective ablation of pit and fissure caries from occlusal surfaces using λ=355-nm laser pulses and air-abrasion demonstrated using PS-OCT and near-IR imaging

    Science.gov (United States)

    Ross, Steven T.; Fan, Kenneth; Fried, Daniel

    2006-02-01

    Several past studies have suggested that lasers with and without added chromophores can be used for the selective removal of dental caries from stained pit and fissures in preparation for composite sealant placement with minimal damage to sound, unstained tooth structure. Polarization sensitive optical coherence tomography (PS-OCT) is a new nondestructive imaging technology that can be used to acquire images of caries lesions in occlusal surfaces. PSOCT is ideally suited to measure the caries depth and severity before and after selective removal from occlusal surfaces. In this study, λ=355-nm laser pulses of 5-ns duration at irradiation intensities ranging from 0.5-1.3 J/cm2 were scanned across tooth surfaces to selectively remove decayed enamel with and without the addition of India ink. PS-OCT images were acquired before and after removal. The laser removal was also compared to air abrasion in order to compare selectivity of these two conservative caries removal technologies.

  4. Corneal abrasion and alkali burn secondary to automobile air bag inflation

    Science.gov (United States)

    Scarlett, Angela; Gee, Paul

    2007-01-01

    A 59‐year‐old woman self presented to the emergency department with a painful right eye following a motor vehicle accident. She had reduced visual acuity and the eye had an alkaline pH with complete corneal uptake of fluorescein. Diagnosis of corneal abrasion and alkali burn to her right eye secondary to inflation of a driver's automobile airbag was made. The eye was irrigated with normal saline. Such injuries, although rare, can easily be identified within the emergency department by the history of exposure, evidence of facial injuries or burns, and an alkaline pH in the inferior cul‐de‐sac of the eye. Early detection and management with ophthalmology review is therefore imperative to prevent irreversible visual impairment. PMID:17901284

  5. Steam sterilization of air turbine dental handpieces.

    Science.gov (United States)

    Edwardsson, S; Svensäter, G; Birkhed, D

    1983-12-01

    The efficacy of autoclaving high-speed dental handpieces was tested in two types of downward displacement steam sterilizers (instrument autoclaves), commonly used in the dentist's office. Eight series of experiments were performed with various sterilization schedules. Lubrication oils with or without antimicrobial agent were used in four of the series. Each handpiece was inoculated with 1 ml of a suspension containing equal amounts of saliva and spores of Bacillus stearothermophilus (approx. 10(6) spores/ml). Neither sterilization at 120-124 degrees C for 20 min nor at 134-136 degrees C for 10 min resulted in complete inactivation of the spores in series in which the instruments were tested without oil or with oil containing no antimicrobial agent. However, when the handpieces were lubricated with oil containing isopropanol and formaldehyde and the schedule 134-136 degrees C/10 min was used, no growth was observed. The results indicate that instrument autoclaves with built-in programs of 120-124 degrees C/20 min and 134-136 degrees C/10 min could have insufficient capacity to sterilize lubricated or unlubricated dental handpieces. The use of oils containing an antimicrobial agent can overcome this problem.

  6. Evaluation of retention of pit and fissure sealants placed with and without air abrasion pretreatment in 6-8 year old children – An in vivo study

    Science.gov (United States)

    Goswami, Mridula

    2017-01-01

    Background The success of pit and fissure sealants is directly related to their retention. The purpose of this study was to assess and compare the retention of pit and fissure sealants placed using acid etch alone and a combination of air abrasion and acid etch techniques. Material and Methods 50 subjects aged 6-8 years were included in the study. Primary second molars and permanent first molars were sealed in all four quadrants using split mouth design. The right maxillary and mandibular molars (Group A) were treated by acid etching alone while the left maxillary and mandibular molars (Group B) were pretreated with air abrasion followed by acid etching before application of pit and fissure sealant. Retention of sealants was checked using Simonsen’s criteria of sealant retention after three and six months of sealant application. Results There was no significant difference in retention of sealants in Group A and Group B (p0.05). Maxillary molars showed superior retention compared to mandibular molars, which was statistically significant at both three and six months (p<0.05). Conclusions Combining air abrasion pretreatment with subsequent acid etching did not result in statistically significant difference in sealant retention compared to acid etching alone in both primary and permanent molars after 3 and 6 months follow up. An additional air abrasion pretreatment step can be avoided in pediatric patients when placing sealants and the procedure can be completed faster with better behavior management using acid etching alone. Key words:Pit and fissure sealant, acid etching, air abrasion. PMID:28210438

  7. The Effect of Air Density on Sand Transport Structures and the Adobe Abrasion Profile: A Field Wind-Tunnel Experiment Over a Wide Range of Altitude

    Science.gov (United States)

    Han, Qingjie; Qu, Jianjun; Dong, Zhibao; Zu, Ruiping; Zhang, Kecun; Wang, Hongtao; Xie, Shengbo

    2013-11-01

    Aeolian sand transport results from interactions between the surface and the airflow above. Air density strongly constrains airflow characteristics and the resulting flow of sand, and therefore should not be neglected in sand transport models. In the present study, we quantify the influence of air density on the sand flow structure, sand transport rate, adobe abrasion profiles, and abrasion rate using a portable wind-tunnel in the field. For a given wind speed, the flow's ability to transport sand decreases at low air density, so total sand transport decreases, but the saltation height increases. Thus, the damage to human structures increases compared with what occurs at lower altitudes. The adobe abrasion rate by the cloud of blowing sand decreases exponentially with increasing height above the surface, while the wind erosion and dust emission intensity both increase with increasing air density. Long-term feedback processes between air density and wind erosion suggest that the development of low-altitude areas due to long-term deflation plays a key role in dust emission, and will have a profound significance for surface Aeolian processes and geomorphology.

  8. 21 CFR 872.6030 - Oral cavity abrasive polishing agent.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Oral cavity abrasive polishing agent. 872.6030... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6030 Oral cavity abrasive polishing agent. (a) Identification. An oral cavity abrasive polishing agent is a device in paste or powder...

  9. Air plasma effect on dental disinfection

    Energy Technology Data Exchange (ETDEWEB)

    Duarte, S.; Murata, R. M.; Saxena, D. [Department of Basic Sciences and Craniofacial Biology, College of Dentistry, New York University, New York, New York 10010 (United States); Kuo, S. P.; Chen, C. Y.; Huang, K. J. [Department of Electrical and Computer Engineering, Polytechnic Institute of New York University, Brooklyn, New York 11202 (United States); Popovic, S. [Department of Physics, Old Dominion University, Norfolk, Virginia 23529 (United States)

    2011-07-15

    A nonthermal low temperature air plasma jet is characterized and applied to study the plasma effects on oral pathogens and biofilms. Experiments were performed on samples of six defined microorganisms' cultures, including those of gram-positive bacteria and fungi, and on a cultivating biofilm sample of Streptococcus mutans UA159. The results show that the plasma jet creates a zone of microbial growth inhibition in each treated sample; the zone increases with the plasma treatment time and expands beyond the entire region directly exposed to the plasma jet. With 30s plasma treatment twice daily during 5 days of biofilm cultivation, its formation was inhibited. The viability of S. mutans cells in the treated biofilms dropped to below the measurable level and the killed bacterial cells concentrated to local regions as manifested by the fluorescence microscopy via the environmental scanning electron microscope. The emission spectroscopy of the jet indicates that its plasma effluent carries an abundance of reactive atomic oxygen, providing catalyst for the observed plasma effect.

  10. Air plasma effect on dental disinfection

    Science.gov (United States)

    Duarte, S.; Kuo, S. P.; Murata, R. M.; Chen, C. Y.; Saxena, D.; Huang, K. J.; Popovic, S.

    2011-07-01

    A nonthermal low temperature air plasma jet is characterized and applied to study the plasma effects on oral pathogens and biofilms. Experiments were performed on samples of six defined microorganisms' cultures, including those of gram-positive bacteria and fungi, and on a cultivating biofilm sample of Streptococcus mutans UA159. The results show that the plasma jet creates a zone of microbial growth inhibition in each treated sample; the zone increases with the plasma treatment time and expands beyond the entire region directly exposed to the plasma jet. With 30s plasma treatment twice daily during 5 days of biofilm cultivation, its formation was inhibited. The viability of S. mutans cells in the treated biofilms dropped to below the measurable level and the killed bacterial cells concentrated to local regions as manifested by the fluorescence microscopy via the environmental scanning electron microscope. The emission spectroscopy of the jet indicates that its plasma effluent carries an abundance of reactive atomic oxygen, providing catalyst for the observed plasma effect.

  11. Corneal Abrasions

    Science.gov (United States)

    ... and lead to a serious condition called a corneal ulcer . That's why it's important to see a doctor to get a corneal abrasion checked out. What Causes a Corneal ... and land on your cornea, tears help to wash the particles away. Sometimes, ...

  12. Cavity cutting efficiency of a Bioglass$^{\\rm TM}$ and alumina powder combination utilized in an air abrasion system

    Indian Academy of Sciences (India)

    IMRAN FAROOQ; IMRAN ALAM MOHEET; EMAD ALSHWAIMI

    2016-10-01

    This study investigated the attempt to replace alumina in the air abrasion system with an alternative material that is effective at cutting and also has remineralization potential. The powder samples were randomized into three groups: group 1—alumina (composed of aluminium and oxygen), group 2—45S5 (composed of 45% silica, 24.5% calcium oxide, 24.5% sodium oxide and 6% phosphorus pentoxide in weight percentage) and group 3—alumina + 45S5. Thirty human enamel blocks and microscope glass slides of 0.5mm thickness were randomly divided into these three groups. The time taken to cut a hole through the glass slide and for the cutting of human enamel blocks was recorded, the cutting time was fixed at 15 s. The depths of the cavities were measured using a periodontal probe and the enamel blocks were then analysed by scanning electronmicroscope (SEM). The mean time taken to cut a hole through the microscope glass slide was 2.96, 23.01 and 3.02 s for groups 1, 2 and 3, respectively. After cutting the human enamel blocks, the mean cavity depths produced were measured to be 2.5, 1.0 and 2.0 mm for groups 1, 2 and 3, respectively. The SEM micrographs revealed that the cavities formed by 45S5 were more conical in shape, whereas cavities produced by alumina and alumina + 45S5 were more cylindrical. The combined use of alumina and 45S5 has demonstrated a promising cutting efficiency and it has the potential to achieve effective cutting with the possibility of the remineralization.

  13. Influence of air-abrasion executed with polyacrylic acid-Bioglass 45S5 on the bonding performance of a resin-modified glass ionomer cement.

    Science.gov (United States)

    Sauro, Salvatore; Watson, Timothy F; Thompson, Ian; Toledano, Manuel; Nucci, Cesare; Banerjee, Avijit

    2012-04-01

    The aim of this study was to test the microtensile bond strength (μTBS), after 6 months of storage in PBS, of a resin-modified glass ionomer cement (RMGIC) bonded to dentine pretreated with Bioglass 45S5 (BAG) using various etching and air-abrasion techniques. The RMGIC (GC Fuji II LC) was applied onto differently treated dentine surfaces followed by light curing for 30 s. The specimens were cut into matchsticks with cross-sectional areas of 0.9 mm(2). The μTBS of the specimens was measured after 24 h or 6 months of storage in PBS and the results were statistically analysed using two-way anova and the Student-Newman-Keuls test (α = 0.05). Further RMCGIC-bonded dentine specimens were used for interfacial characterization, micropermeability, and nanoleakage analyses by confocal microscopy. The RMGIC-dentine interface layer showed no water absorption after 6 months of storage in PBS except for the interdiffusion layer of the silicon carbide (SiC)-abraded/polyacrylic acid (PAA)-etched bonded dentine. The RMGIC applied onto dentine air-abraded with BAG/H(2)O only or with BAG/PAA-fluid followed by etching procedures (10% PAA gel) showed no statistically significant reduction in μTBS after 6 months of storage in PBS. The abrasion procedures performed using BAG in combination with PAA might be a suitable strategy to enhance the bonding durability and the healing ability of RMGIC bonded to dentine.

  14. Decontamination Using a Desiccant with Air Powder Abrasion Followed by Biphasic Calcium Sulfate Grafting: A New Treatment for Peri-Implantitis

    Directory of Open Access Journals (Sweden)

    Giorgio Lombardo

    2015-01-01

    Full Text Available Peri-implantitis is characterized by inflammation and crestal bone loss in the tissues surrounding implants. Contamination by deleterious bacteria in the peri-implant microenvironment is believed to be a major factor in the etiology of peri-implantitis. Prior to any therapeutic regenerative treatment, adequate decontamination of the peri-implant microenvironment must occur. Herein we present a novel approach to the treatment of peri-implantitis that incorporates the use of a topical desiccant (HYBENX, along with air powder abrasives as a means of decontamination, followed by the application of biphasic calcium sulfate combined with inorganic bovine bone material to augment the intrabony defect. We highlight the case of a 62-year-old man presenting peri-implantitis at two neighboring implants in positions 12 and 13, who underwent access flap surgery, followed by our procedure. After an uneventful 2-year healing period, both implants showed an absence of bleeding on probing, near complete regeneration of the missing bone, probing pocket depth reduction, and clinical attachment gain. While we observed a slight mucosal recession, there was no reduction in keratinized tissue. Based on the results described within, we conclude that the use of HYBENX and air powder abrasives, followed by bone defect grafting, represents a viable option in the treatment of peri-implantitis.

  15. Effects of air abrasion with alumina or glass beads on surface characteristics of CAD/CAM composite materials and the bond strength of resin cements

    Directory of Open Access Journals (Sweden)

    ARAO Nobuaki

    2015-12-01

    Full Text Available ABSTRACT Objective The study aimed to evaluate effects of air abrasion with alumina or glass beads on bond strengths of resin cements to CAD/CAM composite materials. Material and Methods CAD/CAM composite block materials [Cerasmart (CS and Block HC (BHC] were pretreated as follows: (a no treatment (None, (b application of a ceramic primer (CP, (c alumina-blasting at 0.2 MPa (AB, (d AB followed by CP (AB+CP, and (e glass-beads blasting at 0.4 MPa (GBB followed by CP (GBB+CP. The composite specimens were bonded to resin composite disks using resin cements [G-CEM Cerasmart (GCCS and ResiCem (RC]. The bond strengths after 24 h (TC 0 and after thermal cycling (TC 10,000 at 4–60°C were measured by shear tests. Three-way ANOVA and the Tukey compromise post hoc tests were used to analyze statistically significant differences between groups (α=0.05. Results For both CAD/CAM composite materials, the None group exhibited a significant decrease in bond strength after TC 10,000 (p0.05. The AB+CP group showed a significantly higher bond strength after TC 10,000 than did the AB group for RC (p<0.05, but not for GCCS. The GBB+CP group showed the highest bond strength for both thermal cyclings (p<0.05. Conclusions Air abrasion with glass beads was more effective in increasing bond durability between the resin cements and CAD/CAM composite materials than was using an alumina powder and a CP.

  16. PENGARUH PERBANDINGAN AIR DAN BUBUK TERHADAP LAMANYA WAKTU SETTING DENTAL STONE

    OpenAIRE

    Sila, Patri

    2012-01-01

    2012 Patri Sila. Dental stone adalah bahan yang terbuat dari gipsum yang kristalisasinya dikontrol secara hati ??? hati dengan tekanan uap dalam wadah tertutup dan biasanya di sebut sebagai ??-hemihidrat. Secara komersial, dental stone dibuat dari gipsum yang dipanaskan pada suhu 125?? C dibawah tekanan uap dalam autoklaf secara terus menerus sehingga terbentuk hemihidrat dengan porositas yang rendah. Tujuan penelitian ini adalah untuk mengetahui pengaruh perbandingan air dan bubuk terh...

  17. Assessment of exposures and potential risks to the US adult population from wear (attrition and abrasion) of gold and ceramic dental restorations.

    Science.gov (United States)

    Richardson, G Mark; Clemow, Scott R; Peters, Rachel E; James, Kyle J; Siciliano, Steven D

    2016-01-01

    Little has been published on the chemical exposures and risks of dental restorative materials other than from dental amalgam and composite resins. Here we provide the first exposure and risk assessment for gold (Au) alloy and ceramic restorative materials. Based on the 2001-2004 US National Health and Nutrition Examination Survey (NHANES), we assessed the exposure of US adults to the components of Au alloy and ceramic dental restorations owing to dental material wear. Silver (Ag) is the most problematic component of Au alloy restorations, owing to a combination of toxicity and proportional composition. It was estimated that adults could possess an average of four tooth surfaces restored with Au alloy before exceeding, on average, the reference exposure level (REL) for Ag. Lithium (Li) is the most problematic component of dental ceramics. It was estimated that adults could possess an average of 15 tooth surfaces restored with ceramics before exceeding the REL for Li. Relative risks of chemical exposures from dental materials decrease in the following order: Amalgam>Au alloys>ceramics>composite resins.

  18. Sustainability of abrasive processes

    DEFF Research Database (Denmark)

    Aurich, J.C.; Linke, B.; Hauschild, Michael Zwicky

    2013-01-01

    This paper presents an overview of research on sustainability of abrasive processes. It incorporates results from a round robin study on ‘‘energy-efficiency of abrasive processes’’ which has been carried out within the scientific technical committee ‘‘abrasive processes’’ (STC G) of CIRP...

  19. PC controlled toothbrush/dentifrice abrasion machine.

    Science.gov (United States)

    Bal, G; Uçtaşli, S; Bekiroğlu, E

    1999-02-01

    A toothbrush/dentifrice abrasion machine was developed to use in dental research laboratory. The mechanism was designed as a hexagonal block driven by two stepping motors which move the mechanism in four directions. In order to control the stepping motors speed, position and direction commands or signals were generated by a software written in C Programming Language and then these commands were applied the stepping motor drives through parallel port of a personal computer. The toothbrush/dentifrice abrasion machine was finally used to measure different longevity of tooth brush. It was experimentally shown that the mechanism can be used for highly accurate position and speed applications.

  20. Infection Control in Air Force Dental Clinics (Second Edition),

    Science.gov (United States)

    1983-11-01

    Gardena CA, 1982. White, S.C., and S. Glaze. Interpatient microbiological cross-contamination after dental radiographic examination . JADA 96:801-804 (May...Patient Examining and Treatment Nonsterile Medium, box of 50 6515-00-477-6722 3.35 Medium, box of 100 6515-00-051-1950 2.16 Medium-large, box of 100 6515...25 Reducing Aerosol Production .................................... 26 Protection Against Aerosols

  1. Ultrasonic magnetic abrasive finishing

    Institute of Scientific and Technical Information of China (English)

    LU Ya-ping; MA Ji; ZHANG Jun-qiang; WANG Long-shan

    2006-01-01

    Put forward a new kind of polishing method, ultrasonic magnetic abrasive finishing (UMAF), and studied its mechanism of improving polishing efficiency. By analyzing all kind of forces acting on single abrasive particle in the polishing process and calculating the size of the composition of forces, get the conclusion that UMAF will enhance the efficiency of the normal magnetic abrasive finishing(MAF) due to the ultrasonic vibration increases the cutting force and depth. At last the idea of designing the UMAF system based on numerical control milling machine is put forward which is convenient to setup and will accelerate the practical application of MAF.

  2. Air sampling for hepatitis B surface antigen in a dental operatory.

    Science.gov (United States)

    Petersen, N J; Bond, W W; Favero, M S

    1979-09-01

    Forty samples of air with a mean sample volume of 104 liters were collected during the treatment of patients whose blood was positive for HBsAG: no samples contained HBsAG and occult blood. These findings suggest that, if environmentally mediated transmission of hepatitis B occurs in the dental operatory, it is more likely to occur through contact with contaminated surfaces than through the airborne route.

  3. Development of hydrophilic dental wax without surfactant using a non-thermal air atmospheric pressure plasma jet

    Science.gov (United States)

    Lee, Jung-Hwan; Kim, Yong-Hee; Choi, Eun-Ha; Kim, Kwang-Mahn; Kim, Kyoung-Nam

    2014-06-01

    Dental wax (DW), a low-melting and high-molecular-weight organic mixture, is widely used in dentistry for forming moulds of teeth. Hydrophilicity is an important property for DW, as a wet dental investment is used to surround the wax before wax burnout is performed. However, recent attempts to improve the hydrophilicity of DW using a surfactant have resulted in the reduced mechanical properties of the dental investment, leading to the failure of the dental restoration. This study applied a non-thermal air atmospheric pressure plasma jet (AAPPJ) for DW surface treatment and investigated its effect on both DW hydrophilicity and the dental investment's mechanical properties. The results showed that the application of the AAPPJ significantly improved the hydrophilicity of the DW, and that the results were similar to that of cleaner-treated DW using commercially available products with surfactant. A surface chemical analysis indicated that the improvement of hydrophilicity was related to an increase in the number of oxygen-related bonds on the DW surface following the removal of carbon hydrate in both AAPPJ and cleaner-treated DW. However, cleaner treatment compromised the mechanical property of the dental investment when the dental investment was in contact with the treated DW, while the AAPPJ treatment did not. Therefore, the use of AAPPJ to treat DW is a promising method for accurate dental restoration, as it induces an improvement in hydrophilicity without harming the dental investment.

  4. Investigation of indoor air volatile organic compounds concentration levels in dental settings and some related methodological issues.

    Science.gov (United States)

    Santarsiero, Anna; Fuselli, Sergio; Piermattei, Alessandro; Morlino, Roberta; De Blasio, Giorgia; De Felice, Marco; Ortolani, Emanuela

    2009-01-01

    The assessment of indoor air volatile organic compounds (VOCs) concentration levels in dental settings has a big health relevance for the potentially massive occupational exposure to a lot of diverse contaminants. The comparison of the VOCs profile relative to indoor conditions and to the corresponding outdoor concentrations, as well as the discovery of possible correlations between specific dental activities and VOCs concentration variations are of utmost importance for offering a reliable characterization of risk for dentists and dental staff health. In this study we review the most relevant environmental studies addressing the VOCs contamination level in dental settings. We analyze the methodological problems this kind of study must face and we report preliminary results of an indoor air investigation, carried out at dental hospital in Italy, the "Ospedale odontoiatrico George Eastman" of Rome, in which general lines for the analysis of dental settings in environmental terms are sketched. The aim of this work is to identify the kind of problems a typical enclosed (non-industrial) environment indoor air investigation has to cope with by means of the analysis of a case study.

  5. Instrumentation of dental implants: a literature review

    Directory of Open Access Journals (Sweden)

    Fabiana de Almeida Curylofo

    2013-03-01

    Full Text Available Introduction and Objective: The aim of this study was to review the literature on the systems used to decontaminate the implant’s surface. Different instruments have been proposed, but there is no agreement in the literature about which methods would be more efficient with no damage to the implant surface. It was reported the use of plastic, carbon fiber, stainless-steel and titanium curettes and also the use of other systems such as ultrasonic points with different tips, rubber cups and air abrasion. Literature review: In most of the studies, the injury caused on the titanium surface at the time of instrumentation was examined. In others, the cell adhesion on the titanium dental implants following instrumentation of the implant surface was observed. Moreover, to enhance cleaning around implants, ultrasonic systems were recently tested. Conclusion: Metal instruments can lead to major damage to implant surface, therefore, they are not indicated for decontamination of dental implants surfaces. Furthermore, non-metallic instruments, such as plastic curettes, rubber cups, air abrasion and some ultrasonic systems seem to be better choices to remove calculus and plaque of the sub- and supra-gingival peri-implant area. It is noteworthy that more studies evaluating the effects of these systems are required to establish best practices to be used in the treatment of patients with dental implants.

  6. Research on Abrasive Wear Resistance of Ni-Ti Coating Prepared by High Velocity Air-fuel Arc Spraying%超音速电弧喷涂Ni-Ti涂层的磨粒磨损性能研究

    Institute of Scientific and Technical Information of China (English)

    张健; 周勇; 张志萍

    2012-01-01

    采用超音速电弧喷涂工艺在2Cr13马氏体不锈钢基体上制备了Ni-Ti涂层.用X射线衍射研究了涂层的相组成,用扫描电镜对涂层的显微结构和磨损后形貌进行了分析,测试了涂层的显微硬度,在橡胶轮磨粒磨损试验机上研究了涂层的耐磨粒磨损性能.结果表明,Ni-Ti涂层主要组织为NiTi(B2)相和一定量的TiO、NiO等氧化物,该涂层不仅有较高的硬度,而且较2Cr13基体有更加良好的耐磨粒磨损性能.%Ni-Ti coating was prepared on 2Crl3 martensitic stainless steel substrate by high velocity air-fuel arc spraying. The phase composition of the coating was investigated by XRD; the microstructure and the worn surface morphology of the coating were analyzed by SEM; the microhardness of the coating was determined; the abrasive resistance of the coating was studied by rubber wheel abrasion tester. The results show that Ni-Ti coating is mainly composed of NiTi (B2) phase and some oxides such as TiO and NiO. The coating is of higher hardness and has much better abrasive wear resistance than 2Crl3 substrate.

  7. Removal of mercury vapor from ambient air of dental clinics using an air cleaning system based on silver nanoparticles

    Directory of Open Access Journals (Sweden)

    Chiman Saeidi

    2015-06-01

    Full Text Available Background & objective: Mercury is a toxic and bio-accumulative pollutant that has adverse effects on environmental and human health. There have been a number of attempts to regulate mercury emissions tothe atmosphere. Silver nanoparticles are a number of materials that have highly potential to absorb mercury and formation of mercury amalgam.The aim of this study is removal of mercury vapors in the dental clinic using a n a ir cleaning system based on silver nanoparticles. Methods: In this study, silver nanoparticles coated on the bed of foam and chemical and structural properties were determined using a number of methods such as UV-VIS-NIR spectroscopy and Scanning Electron Microscope (SEM connected the X-ray Emission Spectroscopy Energy (EDS. The a ir cleaning system efficiency to remove of the mercury vapor in simulated conditions in the laboratory and real conditions in the dental clinicwere measured by Cold Vapor Atomic Absorption Spectroscopy (CVAAS. Results: The images of SEM, showed that average sizeof silver nanoparticles in colloidal solution was ∼ 30nm and distribution of silver nanoparticles coated on foam was good. EDS spectrum confirmed associated the presence of silver nanoparticles coated on foam. The significantly difference observed between the concentration of mercury vapor in the off state (9.43 ± 0.342 μg.m-3 and on state (0.51 ± 0.031μg.m-3 of the a ir cleaning system. The mercury vapor removal efficiencyof the a ir cleaning system was calculated 95%. Conclusion : The air cleaning system based on foam coated by silver nanoparticles, undertaken to provide the advantages such as use facilitating, highly efficient operational capacity and cost effective, have highly sufficiency to remove mercury vapor from dental clinics.

  8. Air-borne microbial contamination of surfaces in a UK dental clinic.

    Science.gov (United States)

    Decraene, Valérie; Ready, Derren; Pratten, Jonathan; Wilson, Michael

    2008-08-01

    Little is known about the number, type, or antibiotic resistance profiles, of air-borne microbes present in hospital settings yet such information is important in designing effective measures to reduce cross-infection. In this study settle plates were used to identify and quantify the air-borne microbes present in a dental clinic. All isolates were identified to species level using partial 16S ribosomal RNA gene sequencing and their susceptibility to ampicillin, chloramphenicol, erythromycin, gentamicin, penicillin, tetracycline or vancomycin was performed. The mean numbers of viable bacteria detected for each sampling occasion during periods of clinical activity and in the absence of such activity were 21.9 x 10(2 )cfu/m2/h and 2.3 x 10(2 )cfu/m2/h respectively. One hundred ninety-three distinct colony morphotypes, comprising 73 species, were isolated during the study and 48% of these were resistant to at least one antibiotic. The mean numbers of different morphotypes detected per sampling occasion were 14.3 and 5 during periods of clinical activity and inactivity respectively. Propionibacterium acnes, Micrococcus luteus and Staphylococcus epidermidis were frequently isolated regardless of whether any clinical activities were taking place. These findings highlight the importance of preventing surfaces from becoming reservoirs of antibiotic-resistant bacteria and thereby contributing to cross-infection in the dental clinic.

  9. Dental caries: Therapeutic possibilities

    Directory of Open Access Journals (Sweden)

    Perić Tamara

    2008-01-01

    Full Text Available Contemporary tendencies in dentistry are based on the concept of maximal protection of healthy tooth tissues. Caries removal has been done traditionally with mechanical rotary instruments that are fast and precise. However, conventional cavity preparation has potential adverse effects to the pulp due to heat, pressure and vibrations. Moreover, drilling often causes pain and requires local anaesthesia, and these procedures are frequently perceived as unpleasant. Etiology, development and prevention of dental caries are better understood today and new restorative materials that bond micromechanically and/or chemically to dental tissues have been introduced. Thus, development of a new, less destructive caries removal technique is allowed. In the last decades, many alternative methods have been introduced in an attempt to replace rotary instruments. These are claimed to be efficient and selective for diseased tissues and to offer comfortable treatment to the patients. New methods include air abrasion, air polishing, ultrasonic, polymer burs, enzymes, systems for chemo-mechanical caries removal, and lasers. The aim of this paper was to discuss various caries removal techniques and possibilities of their use in clinical practice. Based on the literature review it can be concluded that none of the new caries removal methods can completely replace conventional rotary instruments.

  10. Comparação dos valores de desgaste abrasivo e de microdureza de 13 resinas compostas usadas em odontologia através do método do disco retificado Comparing abrasive wear and microhardness of 13 dental composite resins

    Directory of Open Access Journals (Sweden)

    Eduardo C. Bianchi

    2007-06-01

    Full Text Available Atualmente tem-se buscado simplificar a tarefa de caracterização da vida útil de restaurações dentárias realizadas por resinas compostas através de métodos laboratoriais, que são mais rápidos e não sofrem influência de variáveis pessoais inerentes às análises clínicas. Com este propósito, este trabalho apresenta uma nova metodologia de ensaio laboratorial para a avaliação do desgaste abrasivo de resinas compostas através do método do disco retificado. Realizaram-se ensaios de resistência ao desgaste abrasivo com 13 resinas compostas odontológicas e buscou-se analisar o comportamento da resistência ao desgaste abrasivo em relação à microdureza dessas resinas. Com a análise dos resultados concluiu-se que o método de discos retificados é eficiente para a obtenção da resistência ao desgaste abrasivo. Notou-se também ser extremamente pequeno o nível de correlação entre microdureza e desgaste abrasivo o que indica que cada resina composta tem características próprias e que o desgaste é dependente também de outros fatores.It is now commonplace to search for methods to assess the useful lifetime of dental restorations made of resins, which are quicker and less subjective than clinical analyses. With this purpose, this work presents a new methodology based on the grinding disk for evaluating the abrasive wear of composed resins. Resistance tests to the abrasive wear were made with 13 composed resins used as dental material, and a comparison was done with the hardness of those resins. From the data analysis, we concluded that the method of rectified disks is efficient for obtaining the resistance to the abrasive wear. Furthermore, the correlation between hardness and abrasive wear was very small, which indicates that each composed resin has its own characteristics and that the wear also depends on other factors.

  11. O efeito do jateamento do esmalte na força de adesão na colagem de braquetes The effect of air abrasion in enamel adhesion of orthodontic bracket

    Directory of Open Access Journals (Sweden)

    Carla D'Agostini Derech

    2008-06-01

    Full Text Available OBJETIVO: o propósito deste estudo in vitro foi avaliar o efeito do jateamento com óxido de alumínio na adesão de braquetes ortodônticos e compará-lo à tradicional técnica de condicionamento ácido do esmalte. METODOLOGIA: foram utilizados 80 dentes bovinos distribuídos aleatoriamente entre quatro grupos, sendo que a superfície do esmalte foi tratada da seguinte maneira: grupo 1 (somente jateamento com óxido de alumínio, grupo 2 (profilaxia com pedra-pomes e condicionamento com ácido, grupo 3 (jateamento com óxido de alumínio e condicionamento ácido e grupo 4 (somente condicionamento ácido. Após, foi aplicado sistema adesivo e o braquete colado com resina. Os corpos-de-prova foram submetidos ao teste de cisalhamento e análise do IAR. Aos resultados foram aplicados o teste de variância múltipla (ANOVA e a comparação entre pares (Tukey. Para a análise do IAR foi aplicado o teste Qui-quadrado. RESULTADOS: o grupo 1 apresentou a menor resistência ao cisalhamento (3,6MPa e o 3 a maior (13,27MPa. A análise Qui-quadrado do IAR demonstrou que o tratamento da superfície do esmalte tem influência sobre a quantidade de remanescente de resina sobre o esmalte e os grupos 3 e 4 apresentaram a maior quantidade de resina aderida. CONCLUSÕES: o jateamento de óxido de alumínio não deve ser o único procedimento utilizado no preparo da superfície do esmalte na colagem de braquetes, porém, quando associado ao condicionamento ácido, mostrou-se eficaz no aumento da retenção entre esmalte e resina. Novos estudos são necessários visando menor dano do esmalte e adesão satisfatória.AIM: The purpose of this study in vitro was to evaluate the effect of the air abrasion with Al-oxide in the adhesion of orthodontic brackets and compare with traditional technique of acid conditioning of the enamel. METHODS: Eighty bovine teeth distributed randomly between four groups had been used and the surface of the enamel was prepared in the

  12. Ultrasonic Abrasion: An Alternative for Cavity Preparation

    Directory of Open Access Journals (Sweden)

    Áurea Simone Barrôso VIEIRA

    2007-05-01

    Full Text Available Introduction: Restorative dentistry aims to repair damages caused by caries disease. Along the years, researchers have developed effective and less invasive methods with the goal of preserving the teeth from caries destruction. Therefore, the improvement of scientific knowledge, auxiliary diagnostic systems, dental materials, and new instruments has changed the approaches and treatments in this field. In addition to conservative removal of carious tissue, patient’s comfort has also become a concern in modern dentistry.Purpose: Considering that ultrasonic abrasion has attracted great interest of dental professionals, this article discusses an alternative technique for cavity preparation by literature review, addressing its indications, contra-indications, advantages and limitations compared to the conventional high-speed method.Conclusion: There are not many studies on this subject. The available studies have demonstrated several qualities of the ultrasonic abrasion system, but some aspects remain unclear. Therefore, it is important to highlight that laboratorial and clinical studies in primary/permanent teeth should be conducted to elucidate questionable issues, such as time of cavity preparation, topography, presence of smear layer and microleakage, in order to offer safety to the extensive use of this new technology for both the professional and the patient. In this context, the dentist should always be attentive to innovations referring to minimally invasive techniques.

  13. Comparing Effects of Four Toothpaste Types (Nasim, Crest 7, Crest Sensitivity and Daroghar3) on Rate of Enamel Abrasion

    OpenAIRE

    2016-01-01

    Introduction: Toothpaste should have the most plaque removal efficacy with the least abrasiveness. The aim of this study was to evaluate enamel abrasion induced by four toothpaste types. Methods: In this in vitro experimental study, 24 dental samples were divided into four groups of six. The initial surface roughness was measured with the roughness measuring device. Regarding abrasion test with Daroghar3, Nasim, Crest7 and Crest sensitivity toothpastes, samples were located in V8cross brus...

  14. Air pollution/working activity correlation: a case study in a dental hospital.

    Science.gov (United States)

    Santarsiero, Anna; Fuselli, Sergio; Morlino, Roberta; Minniti, Gianluca; De Felice, Marco; Ortolani, Emanuela

    2011-02-01

    The paper deals with a multidimensional approach demonstrating a direct link between the entity of ongoing dentistry activity (number and kind of interventions) and specific pollution components. Simultaneously indoor/outdoor air concentrations of a set of volatile organic compounds (VOCs) and activity variables, describing the amount and nature of ongoing dentistry activities, were monitored over a year at a dental hospital located in an urban area. Principal Component Analysis (PCA) was used to single out mutually orthogonal pollution components which were then correlated to "pathology" factors arising from the analysis of dentistry activity indexes. The use of a multidimensional perspective allowed us to obtain a statistically significant model of the link between level of pollution and dentistry activity. In particular, the correlation approach linking pollution results to pathological variables allows us to establish a causative link even in the presence of sub-threshold concentrations of pollutants.

  15. Abrasion Testing of Products Containing Nanomaterials, SOP-R-2: Scientific Operating Procedure Series: Release (R)

    Science.gov (United States)

    2016-04-01

    chamber with controlled, HEPA-filtered air inflow connected to an instrument bank (CPC, FMPS) and in-line filters to collect abrasion-generated particles...Guiot, G. Uzu, J. Chatenet and F. Tardif. 2011. Characterization of abrasion-induced nanoparticle release from paints into liquids and air. Journal of

  16. Dental enamel: qualitative evaluation of the surface after application of aluminum oxide (microetching using the scanning electron microscope

    Directory of Open Access Journals (Sweden)

    SILVA Paulo César Gomes

    2000-01-01

    Full Text Available Dentistry nowadays can count on a wide range of resources to treat patients. With the development of adhesive materials and several newly introduced restorative techniques, the dental structure can be subjected to different sorts of surface treatment. The use of aluminum oxide flow at high speed to remove dental structure was described by Black in 1945, however, the literature regarding the use of aluminum oxide jet is still scarce, as far as the alterations occurring in the dental structure are concerned. At the present, with the development of new abrasive air equipment, microabrasion has been added to several adhesive restorative techniques, in the preparation of the dental surface and of inner surfaces of indirect restorations, which will receive the application of adhesive materials. The aim of this study was to assess the alterations produced by abrasive air applied on the dental enamel by means of electronic microscopy, taking into consideration micromorphological surface alterations. The importance of this study is based on the fact that alternative surface treatments both chemical and mechanical could be introduced in surface priming, including dental enamel priming.

  17. The effects of the diamond-like carbon film on the abrasive resistance of dental bur%类金刚石膜在牙科车针表面的初步应用

    Institute of Scientific and Technical Information of China (English)

    李雅瑾; 韩建民; 张仁国; 葛春玲; 王兵

    2011-01-01

    Objective; To study the effect of the diamond-like carbon film ( DLC) on the abrasive resistance of dental bur. Methods; Unused new diamond burs. Tungsten steel resin grinding heads and low-speed carbon steel ball burs were divided into two groups respectively, those with DLC costing were used in test group, those without coating were used as the controls. For the diamond bur, an experienced dentist used the coating and non-coating diamond burs respectively to grind the extracted tooth under the standard of all-crown reduction. One bur was used to grind five teeth, the effects of the two groups were judged by the dentist subjective feeling. For the Tungsten steel resin grinding head, the time of breaking through the resin block under the same rotation speed and same load were compared for the coating and non-coating heads. For the carbon steel ball bur, the edge of the ball burs was examined under microscope with the magnification of 75 times after the bur prepared type I cavity in three extracted teeth. Results: The coating diamond burs were belter than the non-coating judged by the dentist subjective feeling. The time of breaking through the resin block of the Tungsten steel resin grinding head in coating group was less than that in non-coating group, The wear of low-speed ball bur in coating group was slighter than that in non-coating group. Conclusion: DLC can increase the cutting efficiency, decrease the wear, and extend the working life of the bur, especially for the Tungsten steel grinding head and low-speed carbon steel ball bur.%目的:通过类金刚石镀膜(DLC)的方法提高牙科车针的耐磨性.方法:选择临床常用3种类型新车针,每种车针选择同种型号若干支,一组非镀膜作为对照组,一组镀膜作为试验组.对于金刚砂车针:由1名临床经验丰富的医生,使用镀膜与未镀膜车针,按照全冠牙体预备要求磨除离体牙(同一名正畸患者拔除的同名牙),同一根车针磨除5颗离体牙,记

  18. A Profilometric Study to Assess the Role of Toothbrush and Toothpaste in Abrasion Process

    Directory of Open Access Journals (Sweden)

    Sandeep Kumar

    2015-09-01

    Full Text Available Statement of the Problem: Despite of many studies conducted on toothbrushes and toothpaste to find out the culprit for abrasion, there is no clear cut evidence to pin point the real cause for abrasion. Purpose: An in vitro assessment of the role of different types of toothbrushes (soft/ medium/hard in abrasion process when used in conjunction with and without a dentifrice. Materials and Method: Forty five freshly extracted, sound, human incisor teeth were collected for this study. Enamel specimens of approximately 9 mm2 were prepared by gross trimming of extracted teeth using a lathe machine (Baldor 340 Dental lathe; Ohio, USA. They were mounted on separate acrylic bases. The specimens were divided into three groups, each group containing 15 mounted specimens. Group 1 specimens were brushed with soft toothbrush; Group 2 brushed with medium toothbrush and Group 3 with hard toothbrush. Initially, all the mounted specimens in each group were brushed using dentifrice and then the same procedure was repeated with water as control. Profilometric readings were recorded pre and post to tooth brushing and the differences in readings served as proxy measure to assess surface abrasion. These values were then compared to each other. Kruskal Wallis and Mann-Whitney U test were performed. Results: The results showed that brushing, with water alone, caused less abrasion than when toothpaste was added (p< 0.008. When brushed with water, the harder toothbrush caused more abrasion (higher Ra-value, but when toothpaste was added, the softer toothbrush caused more abrasion (p< 0.001. Conclusion: Besides supporting the fact that toothpaste is needed to create a significant abrasion, this study also showed that a softer toothbrush can cause more abrasion than harder ones. The flexibility of bristles is only secondary to abrasion process and abrasivity of dentifrice has an important role in abrasion process.

  19. Abrasion of ultrafine WC-Co by fine abrasive particles

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Abrasive wear of a series of WC-(5%-14%, mass fiaction)Co hardmetals was investigated employing coarse and fine SiC abrasive under two-body dry abrasion conditions with pin-on-disc and edge-on-disc test arrangements. Unexpectedly, it is found that submicron grades demonstrate substantially higher wear rates comparing with the coarse grades if fine abrasive is utilized in pin-on-disc tests. Such a behavior is attributed to changes in a ratio of abrasive size to size of hard phase as finer abrasive is used.The edge-on-disc test demonstrates that edge wear may be described in two stages with the highest wear rates at the beginning stage.This behavior is associated with a transition of wear mechanisms as edge is wider due to wear. Compared with the ultrafine grades of the same Co content, the coarse grades demonstrate higher wear rates at the beginning, but lower wear rates at the final stage. Wear rates and mechanisms observed at final stage correlate well to the results observed for pin-on-disc tests employing fine abrasive.

  20. PENGARUH PENGGUNAAN BEBERAPA JENIS AIR BERDASARKAN KESADAHANNYA TERHADAP WAKTU PENGERASAN AKHIR DENTAL STONE TIPE IV

    OpenAIRE

    MA???RIFAT, SANI

    2014-01-01

    2014 Sani Ma???rifat. Kalsium sulfat ??-hemihidrat sering disebut sebagai dental stone. Dental stone terdiri atas tiga tipe yaitu Tipe III, Tipe IV (Kekuatan Tinggi), Tipe V (Kekuatan Tinggi, Ekspansi Tinggi). Dental Stone Tipe IV ( kadang disebut sebagai stone kelas II, densite atau improved stone) merupakan gipsum yang ideal digunakan untuk pembuatan dai, karena dai biasanya digunakan untuk preparasi kavitas dengan malam yang diukir sehingga dibutuhkan mod...

  1. PENGARUH PENGGUNAAN BEBERAPA JENIS AIR BERDASARKAN KESADAHANNYA TERHADAP WAKTU PENGERASAN AKHIR Dental Stone Tipe III

    OpenAIRE

    SASMITA MD, SITI ZULHAJJAH TRIPALU

    2016-01-01

    2016 Kalsium sulfat ??-hemihidrat sering disebut sebagai dental stone. Dental stone terdiri atas tiga tipe yaitu Tipe III, Tipe IV (Kekuatan Tinggi), Tipe V (Kekuatan Tinggi, Ekspansi Tinggi). Dental Stone Tipe III merupakan gipsum yang ideal digunakan untuk pembuatan dai, karena dai biasanya digunakan untuk preparasi kavitas dengan malam yang diukir sehingga dibutuhkan model yang tahan abrasi. Tujuan penelitian ini adalah untuk mengetahui pengaruh penggunaan beberap...

  2. [Dental caries--therapeutic possibilities].

    Science.gov (United States)

    Perić, Tamara; Marković, Dejan; Zivković, Slavoljub

    2008-01-01

    Contemporary tendencies in dentistry are based on the concept of maximal protection of healthy tooth tissues. Caries removal has been done traditionally with mechanical rotary instruments that are fast and precise. However, conventional cavity preparation has potential adverse effects to the pulp due to heat, pressure and vibrations. Moreover, drilling often causes pain and requires local anaesthesia, and these procedures are frequently perceived as unpleasant. Etiology, development and prevention of dental caries are better understood today and new restorative materials that bond micromechanically and/or chemically to dental tissues have been introduced. Thus, development of a new, less destructive caries removal technique is allowed. In the last decades, many alternative methods have been introduced in an attempt to replace rotary instruments. These are claimed to be efficient and selective for diseased tissues and to offer comfortable treatment to the patients. New methods include air abrasion, air polishing, ultrasonic, polymer burs, enzymes, systems for chemo-mechanical caries removal, and lasers. The aim of this paper was to discuss various caries removal techniques and possibilities of their use in clinical practice. Based on the literature review it can be concluded that none of the new caries removal methods can completely replace conventional rotary instruments.

  3. Rubberized Concrete Durability Against Abrasion

    Directory of Open Access Journals (Sweden)

    Md Noor Nurazuwa

    2016-01-01

    Full Text Available Durability performance of rubberized concrete against abrasion is presented in this paper. Surface depth loss was measured when abrasion load was constantly applied on concrete surface at each 500 interval rotation. Specimen with water-to cement ratio of 0.50 and 0.35 was prepared and tested at 28 days of curing age. In addition, 10% silica fume, SF was added to provide denser concrete and to understand its effectiveness against wear when added with crumb rubber. Results showed that crumb rubber shows good potential in providing abrasion resistance to concrete mix. However, in the case of rubberized concrete with silica fume, abrasion resistance was found to be slightly decreased with compressive strength more than 50N/mm2 due to the lack of low elastic modulus of CR particles to accommodate with denser cement matrix.

  4. Reducing Staphylococcus aureus bacterial counts in a dental clinic using an Ionic Breeze air purifier: a preliminary study.

    Science.gov (United States)

    Hubar, J Sean; Pelon, William; Strother, Elizabeth A; Sicard, F Scott

    2009-01-01

    Aerosols and droplets generated by dental procedures are contaminated with blood and bacteria and represent a potential route for the transmission of disease. This study sought to determine if Ionic Breeze air purifiers are effective in collecting and destroying bacteria found in dental aerosols (such as Staphylococcus aureus). This study placed one Sharper Image Professional Series Ionic Breeze Quadra unit and one Ionic Breeze GP unit (with germicidal protection) in dental operatories within the Louisiana State University School of Dentistry. After six hours of operation, bacterial samples were collected and streaked over surfaces of petri dishes containing trypticase soy sucrose bacitracin agar that had been supplemented with 5% sheep blood. The samples were incubated at 37 degrees C for 48 hours; at that point, the microbial colonies were counted. Additional testing was performed on suspect colonies to identify S. aureus strains and to determine if any of those isolates were pathogenic with or without antibiotic resistance. The Ionic Breeze GP unit killed more than 99% of all bacteria on the stainless steel collecting blades. The non-germicidal Ionic Breeze Quadra air purifier collected numerous bacteria that were found to include some pathogenic strains of S. aureus; however, none of these were resistant to antibiotics.

  5. Application of the total etching technique or self-etching primers on primary teeth after air abrasion Aplicação da técnica de condicionamento total ou de "primers" autocondicionantes em dentes decíduos após abrasão a ar

    Directory of Open Access Journals (Sweden)

    Fábio Renato Manzolli Leite

    2005-09-01

    Full Text Available Since the use of air abrasion has grown in pediatric dentistry, the aim of this study was to evaluate, by means of shear bond strength testing, the need to use the total etching technique or self-etching primers on dentin of primary teeth after air abrasion. Twenty-five exfoliated primary molars had their occlusal dentin exposed by trimming and polishing. Specimens were treated by: Air abrasion + Scotchbond MultiPurpose adhesive (G1; 37% phosphoric acid + Scotchbond MP adhesive (G2; Clearfil SE (G3; Air abrasion + 37% phosphoric acid + Scotchbond MP adhesive (G4; Air abrasion + Clearfil SE (G5. On the treated surface, a cylinder of 2 mm by 6 mm was made using a composite resin (Z100. Duncan's test showed that: (G2 = G3 = G5 > (G1 = G4. The use of a self-etching primer on air abraded dentin is recommended to obtain higher bond strengths.Como o uso da abrasão a ar tem aumentado em odontopediatria, o objetivo deste trabalho foi avaliar a resistência ao cisalhamento da resina composta Z100 sobre a superfície dentinária de dentes decíduos após abrasionamento a ar associado ou não a técnica de condicionamento total (ácido fosfórico + Scotchbond Multi Purpose ou "primer" autocondicionante (Clearfil SE Bond. A superfície oclusal de 25 molares decíduos foi removida para exposição completa da superfície dentinária. Após polimento com lixas abrasivas, foram divididos em 5 grupos (5 espécimes em cada tratados por abrasão + adesivo Scotchbond (G1; condicionamento ácido + adesivo Scotchbond (G2; adesivo Clearfil (G3; abrasão a ar + condicionamento ácido + adesivo Scotchbond (G4; abrasão a ar + adesivo Clearfil (G5. Uma matriz bipartida foi adaptada à superfície dentinária e preenchida com resina composta. Após polimerização, corpos-de-prova de 2 mm x 6 mm foram obtidos. O teste de Duncan mostrou a desigualdade (G1 = G4 < (G2 = G3 = G5. Desse modo, conclui-se que, após o abrasionamento dentinário, deve ser utilizado o sistema de

  6. 30 CFR 72.610 - Abrasive blasting.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Abrasive blasting. 72.610 Section 72.610... HEALTH STANDARDS FOR COAL MINES Miscellaneous § 72.610 Abrasive blasting. (a) Surface and underground mines. When an abrasive blasting operation is performed, all exposed miners shall properly...

  7. 30 CFR 58.610 - Abrasive blasting.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Abrasive blasting. 58.610 Section 58.610... SAFETY AND HEALTH HEALTH STANDARDS FOR METAL AND NONMETAL MINES Miscellaneous § 58.610 Abrasive blasting. (a) Surface and underground mines. When an abrasive blasting operation is performed, all...

  8. Visualisation of Abrasive Particles in Suction Part of Abrasive Cutting Head

    OpenAIRE

    M. Zeleňák; Klich, J. (Jiří); Hlaváček, P.; Foldyna, J. (Josef); Sitek, L. (Libor)

    2013-01-01

    The development of numerical model of processes occurring in the abrasive water jet cutting head during the process of creation and forming of abrasive water jet is currently in the progress at the Institute of Geonics in Ostrava. Verification of the model requires among others to determine behaviour of abrasive particles at the input of the cutting head. Therefore, visualisation of abrasive particles at the input using various parameters of abrasive jet and subsequent analysis was...

  9. Observation of the clinical effect of the occlusal reconstruction treatment on patients with temporomandibular joint disorder as well as severe dental abrasion%牙列重度磨耗伴颞下颌关节紊乱病咬合重建序列治疗临床疗效观察

    Institute of Scientific and Technical Information of China (English)

    黄静莲; 曹云娟

    2012-01-01

    目的 观察分析牙列重度磨耗伴颞下颌关节紊乱病(TMD)患者咬合重建序列治疗的疗效.方法 选取牙列重度磨耗伴TMD患者11例,检查记录TMD及其相关症状,然后进行咬合重建序列治疗,治疗完成3个月、6个月及12个月后,将治疗后的TMD及其相关症状与治疗前相比较,对相关数据进行统计分析.结果 治疗后11例患者均感满意且咀嚼有力,关节弹响、关节疼痛及咬合干扰治疗前后的比较存在统计学意义(P<0.05).结论 咬合重建后,患者满意度较高,其TMD症状有明显改善,髁突位置在短期内无明显改善.%Objective Observe and analyse the clinical effect of the occlusal reconstruction treatment on patients with temporomandibular joint disorder(TMD) as well as severe dental abrasion. Methods 11 patients with TMD and severe abrasion were given occlusal reconstruction treatment after records of their situation of TMD and related symptoms. 3,6,12 months after operation,compare TMD and related symptorms with those before operation. Data were analysed statistically. Kelusts 11 patients given the treatment were all satisfied with the correct and effective occlusion. There were significantly statistical differences (P <0.05) in the comparison before and after the treatment in joint-snapping,joint-paining and occlusal interference. Conclusions Patients are highly satisfied after occlusal reconstruction , and their symptoms about TMD improve obviously. There was no variation of the mandibular condyle position in short time.

  10. Computed tomography to quantify tooth abrasion

    Science.gov (United States)

    Kofmehl, Lukas; Schulz, Georg; Deyhle, Hans; Filippi, Andreas; Hotz, Gerhard; Berndt-Dagassan, Dorothea; Kramis, Simon; Beckmann, Felix; Müller, Bert

    2010-09-01

    Cone-beam computed tomography, also termed digital volume tomography, has become a standard technique in dentistry, allowing for fast 3D jaw imaging including denture at moderate spatial resolution. More detailed X-ray images of restricted volumes for post-mortem studies in dental anthropology are obtained by means of micro computed tomography. The present study evaluates the impact of the pipe smoking wear on teeth morphology comparing the abraded tooth with its contra-lateral counterpart. A set of 60 teeth, loose or anchored in the jaw, from 12 dentitions have been analyzed. After the two contra-lateral teeth were scanned, one dataset has been mirrored before the two datasets were registered using affine and rigid registration algorithms. Rigid registration provides three translational and three rotational parameters to maximize the overlap of two rigid bodies. For the affine registration, three scaling factors are incorporated. Within the present investigation, affine and rigid registrations yield comparable values. The restriction to the six parameters of the rigid registration is not a limitation. The differences in size and shape between the tooth and its contra-lateral counterpart generally exhibit only a few percent in the non-abraded volume, validating that the contralateral tooth is a reasonable approximation to quantify, for example, the volume loss as the result of long-term clay pipe smoking. Therefore, this approach allows quantifying the impact of the pipe abrasion on the internal tooth morphology including root canal, dentin, and enamel volumes.

  11. Mercury poisoning dentistry: high-level indoor air mercury contamination at selected dental sites.

    Science.gov (United States)

    Khwaja, Mahmood A; Abbasi, Maryam Shabbir

    2014-01-01

    Mercury (Hg), also known as quick silver, is an essential constituent of dental amalgam. It is a toxic substance of global concern. Children are more at risk from mercury poisoning which affects their neurological development and brain. In the past, a number of studies at dental sites in many countries have been carried out and reported. The present report briefly describes and discusses our recent investigations carried out at 34 dental sites (teaching institutions, hospitals and private clinics) in Pakistan. It is evident from the data that at many sites the indoor mercury vapor levels exceed far above the permissible limit recommended for safe physical and mental health. At these sites, public in general and the medical, paramedical staff and vulnerable population in particular, are at most serious risk to health resulting from exposure to toxic and hazardous mercury. To minimize such risk, some of the recommendations are, best in-house environmental practices for occupational health and safety, mercury contaminated waste reduction at source, mercury specific legislation and ratification of Minamata convention on mercury by Pakistan and other world governments at the earliest time possible.

  12. Abrasion behavior of graphite pebble in lifting pipe of pebble-bed HTR

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Ke; Su, Jiageng [Institute of Nuclear and New Energy Technology, Advanced Nuclear Energy Technology Cooperation Innovation Center, The Key Laboratory of Advanced Nuclear Engineering and Safety, Ministry of Education, Beijing 10084 (China); Zhou, Hongbo [Institute of Nuclear and New Energy Technology, Advanced Nuclear Energy Technology Cooperation Innovation Center, The Key Laboratory of Advanced Nuclear Engineering and Safety, Ministry of Education, Beijing 10084 (China); Chinergy Co., LTD., Beijing 100193 (China); Peng, Wei; Liu, Bing [Institute of Nuclear and New Energy Technology, Advanced Nuclear Energy Technology Cooperation Innovation Center, The Key Laboratory of Advanced Nuclear Engineering and Safety, Ministry of Education, Beijing 10084 (China); Yu, Suyun, E-mail: suyuan@tsinghua.edu.cn [Center for Combustion Energy, The Key Laboratory for Thermal Science and Power Engineering, Ministry of Educations, Tsinghua University, Beijing 10084 (China)

    2015-11-15

    Highlights: • Quantitative determination of abrasion rate of graphite pebbles in different lifting velocities. • Abrasion behavior of graphite pebble in helium, air and nitrogen. • In helium, intensive collisions caused by oscillatory motion result in more graphite dust production. - Abstract: A pebble-bed high-temperature gas-cooled reactor (pebble-bed HTR) uses a helium coolant, graphite core structure, and spherical fuel elements. The pebble-bed design enables on-line refueling, avoiding refueling shutdowns. During circulation process, the pebbles are lifted pneumatically via a stainless steel lifting pipe and reinserted into the reactor. Inevitably, the movement of the fuel elements as they recirculate in the reactor produces graphite dust. Mechanical wear is the primary source of graphite dust production. Specifically, the sources are mechanisms of pebble–pebble contact, pebble–wall (structural graphite) contact, and fuel handling (pebble–metal abrasion). The key contribution to graphite dust production is from the fuel handling system, particularly from the lifting pipe. During pneumatic lift, graphite pebbles undergo multiple collisions with the stainless steel lifting pipe, thereby causing abrasion of the graphite pebbles and producing graphite dust. The present work explored the abrasion behavior of graphite pebble in the lifting pipe by measuring the abrasion rate at different lifting velocities. The abrasion rate of the graphite pebble in helium was found much higher than those in air and nitrogen. This gas environment effect could be explained by either tribology behavior or dynamic behavior. Friction testing excluded the possibility of tribology reason. The dynamic behavior of the graphite pebble was captured by analysis of the audio waveforms during pneumatic lift. The analysis results revealed unique dynamic behavior of the graphite pebble in helium. Oscillation and consequently intensive collisions occur during pneumatic lift, causing

  13. Effect of air moisture content on adhesion to dentine: a comparison of dental air/water syringe tips.

    Science.gov (United States)

    Lau, A; Bennani, V; Chandler, N; Hanlin, S; Lowe, B

    2014-09-01

    This study aimed to evaluate the spray pattern and air moisture content produced by single-use syringe and multiple-use syringe tips. The drying efficacy was evaluated by analyzing the spray and by detecting the presence of moisture in the air blast through the tips. Single-use tips had a more consistent spray pattern and produced a moisture-free airflow compared to the multiple-use tips. The differences were statistically significant. Adhesion to dentine between tooth preparations dried with the two tips was evaluated using a tensile test. The differences were statistically insignificant.

  14. Product kerma in the air-area and radiation dose in dental radiodiagnosis; Produto kerma ar-area e dose efetiva em radiodiagnostico odontologico

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Alessandro Martins da, E-mail: amcosta@usp.br [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Filosofia, Ciencias e Letras. Dept. de Fisica

    2014-07-01

    The main purpose of patient dosimetry in diagnostic radiology is to determine dosimetric quantities for the establishment and use of reference levels and comparative risk assessment. In recent publications the use of the air kerma-area product, PKA, has been suggested in dental radiology, as this quantity is more closely related to risk. The aim of this study was to perform a preliminary survey of PKA and effective dose in different types of dental examinations. The future perspective is a large-scale survey for the establishment and use of diagnostic reference levels in dentistry in Brazil. (author)

  15. Clasp retention and composites: an abrasion study.

    Science.gov (United States)

    Davenport, J C; Hawamdeh, K; Harrington, E; Wilson, H J

    1990-08-01

    An in vitro test for screening the abrasion resistance and abrasivity of composite resins when used to provide tooth undercuts for removable partial denture clasps is described. In the present study nine composite resins were tested against wrought stainless steel round clasps. The results indicated that the abrasion of any of the composites tested was unlikely to cause a noticeable loss of retention in the clinical situation. However, there was marked abrasion of the clasps by two of the composites which would be likely to be clinically relevant.

  16. Progress in abrasive and grinding technology

    CERN Document Server

    Xu, Xipeng

    2009-01-01

    The grinding and abrasive processing of materials are machining techniques which use bonded or loose abrasives to remove material from workpieces. Due to the well-known advantages of grinding and abrasive processes, advances in abrasive and grinding technology are always of great import in enhancing both productivity and component quality. In order to highlight the recent progress made in this field, the editor invited 21 world-wide contributions with the aim of gathering together all of the achievements of leading researchers into a single publication. The authors of the 21 invited papers, of

  17. A Study of the Pickup of Abrasive Particles during Abrasion of Annealed Aluminum on Silicon Carbide Abrasive Papers,

    Science.gov (United States)

    annealed aluminium during abrasion on silicon carbide abrasive papers. Neither optical nor scanning electron microscopy adequately characterises the...despite its limitations when examining rough surfaces. The present results show that the pickup of silicon carbide particles increases with increase in

  18. On the abrasion of heat-treated 2.8C21Cr1Mo white cast iron

    Energy Technology Data Exchange (ETDEWEB)

    Al-Rubaie, Kassim S.; Preti, Orlando [Centro Universitario SOCIESC, Joinville (Brazil). Engenharia Mecanica; Pohl, Michael [Bochum Univ. (Germany). Inst. fuer Werkstoffe

    2016-09-15

    The abrasion behaviour of heat-treated 2.8C21Cr1Mo cast iron was studied. The specimens were destabilised at two temperatures, 980 and 1050 C, for 4 h, air hardened, and then tempered at five temperatures, 220, 320, 400, 500, and 620 C, for 2 h followed by air cooling. Using a pin-on-plate abrasion apparatus, the specimens were abraded on four types of bonded abrasives (silicon carbide, corundum, flint, and glass). The effect of work hardening on the abrasion resistance was investigated. It was found that the increase in alloy hardness produced by heat treatment had little effect on the abrasion resistance against silicon carbide or corundum; the inverse was true against flint or glass. The as-hardened structure containing 40% retained austenite gave the best abrasion resistance, whereas the hardened and tempered at 620 C showed the worst. Both bulk hardness and matrix hardness before wear correlated poorly with the abrasion resistance. Therefore, a general model ''equivalent hardness'' was developed, in which the hardness of the abraded matrix was considered. With this model, the abrasion behaviour can be clearly analysed.

  19. Dental Amalgam

    Science.gov (United States)

    ... and Medical Procedures Dental Devices Dental Amalgam Dental Amalgam Share Tweet Linkedin Pin it More sharing options Linkedin Pin it Email Print Dental amalgam is a dental filling material which is used ...

  20. Restorative resins: abrasion vs. mechanical properties.

    Science.gov (United States)

    Jørgensen, K D

    1980-12-01

    The purpose of the present work was to examine whether it is possible by simple and reliable laboratory tests to evaluate the abrasion by food of Class 1 restorative resins. The results point to the following main conclusions: for the smooth-surface resins, i.e. the micro-filled composite and the unfilled resins, the Wallace hardness test appears to be a valid parameter for abrasion; the greater the depth of penetration of the Vickers diamond of this apparatus, the more severe abrasion is to be expected. The mode of abrasion in this type of resin is scratching. Porosity in the resins strongly enhances the abrasion. For the rough-surface resins, i.e. the conventional composites, a dual effect of the filler particles was concluded. The filler particles on the one hand protect the matrix against abrasion, but cause, on the other hand, in time an increase of the surface roughness of the composite and thereby via increased friction an increase of the abrasion. Considerations on possible ways to improve the present-day restorative resins are presented. It is stressed that the results obtained refer only to abrasion of Class 1 fillings by food.

  1. Life cycle and sustainability of abrasive tools

    CERN Document Server

    Linke, Barbara

    2016-01-01

    This monograph focuses on abrasive tools for grinding, polishing, honing, and lapping operations. The book describes the life cycle of abrasive tools from raw material processing of abrasive grits and bonding, manufacturing of monolithic or multi-layered tools, tool use to tool end-of-life. Moreover, this work highlights sustainability challenges including economic, environmental, social and technological aspects. The target audience primarily comprises research and industry experts in the field of manufacturing, but the book may also be beneficial for graduate students.

  2. The abrasion and impact-abrasion behavior of austempered ductile irons

    Energy Technology Data Exchange (ETDEWEB)

    Hawk, Jeffrey A.; Dogan, Omer N.; Lerner, Y.S. (University of Northern Iowa)

    1998-01-01

    Austempering of ductile irons has led to a new class of irons, Austempered Ductile Irons (ADIs), with improved mechanical strength and fracture toughness lacking in gray cast irons. Laboratory wear tests have been used to evaluate the abrasive and impact-abrasive wear behavior of a suite of ADIs. The use of high-stress, two-body abrasion, low-stress, three-body abrasion, and impact-abrasion tests provides a clear picture of the abrasive wear behavior of the ADIs and the mechanisms of material removal. When combined with hardness measurements, fracture toughness and a knowledge of the microstructure of the ADIs, the overall performance can be assessed relative to more wear resistant materials such as martensitic steels and high-chromium white cast irons

  3. Performance of recycling abrasives in rock cutting by abrasive water jet

    Institute of Scientific and Technical Information of China (English)

    Gokhan Aydin

    2015-01-01

    Rock cutting performance of recycling abrasives was investigated in terms of cutting depth, kerf width, kerf taper angle and surface roughness. Gravity separation technique was employed to separate the abrasives and the rock particles. The recycling abrasive particles were then dried and sieved for determination of their disintegration behaviors. Before each cutting with recycling abrasives, the abrasive particles less than 106mm were screened out. It is revealed that a considerable amount of used abrasives can be effectively reused in the rock cutting. The reusabilities of abrasives are determined as 81.77%, 57.50%, 34.37%and 17.72%after the first, second, third and fourth cuttings, respectively. Additionally, it is determined that recycling must be restricted three times due to the excessive disintegration of abrasives with further recycling. Moreover, it is concluded that cutting depth, kerf width and surface roughness decreases with recycling. No clear trend is found between the kerf taper angle and recycling. Particle size distribution is determined as an important parameter for improving the cutting performance of recycling abrasives.

  4. The measurement of abrasive particles velocities in the process of abrasive water jet generation

    Science.gov (United States)

    Zeleňák, Michal; Foldyna, Josef; Říha, Zdeněk

    2014-08-01

    An optimization of the design of the abrasive cutting head using the numerical simulation requires gathering as much information about processes occurring in the cutting head as possible. Detailed knowledge of velocities of abrasive particles in the process of abrasive water jet generation is vital for the verification of the numerical model. A method of measurement of abrasive particles at the exit of focusing tube using the FPIV technique was proposed and preliminary tests are described in the paper. Results of analysis of measured velocity fields are presented in the paper.

  5. Third abrasive wear mode: is it possible?

    Directory of Open Access Journals (Sweden)

    Ronaldo Câmara Cozza

    2014-04-01

    Full Text Available The objective of this paper is to propose an initial discussion on the characterization of a third abrasive wear mode. The results obtained in a previous work [1] under different test conditions revealed the occurrence of the superposition of the “rolling” and “grooving” abrasive wear modes. This phenomenon was denoted “micro-rolling abrasion” due to the observation that “rolling abrasion” was found to act on “grooving abrasion”.

  6. Emission factors and source apportionment for abrasion particles produced by road traffic

    Science.gov (United States)

    Bukowiecki, N.; Lienemann, P.; Figi, R.; Hill, M.; Richard, A.; Furger, M.; Rickers, K.; Cliff, S. S.; Baltensperger, U.; Gehrig, R.

    2009-04-01

    Particle emissions of road traffic are generally associated with fresh exhaust emissions only. However, recent studies identified a clear contribution of non-exhaust emissions to the PM10 load of the ambient air. These emissions consist of particles produced by abrasion from brakes, road wear, tire wear, as well as resuspension of deposited road dust. For many urban environments, quantitative information about the contributions of the individual abrasion processes is still scarce. For effective PM10 reduction scenarios it is of particular interest to know whether road wear, resuspension or fresh abrasion from vehicles is dominating the non-exhaust PM10 contribution. In Switzerland, the emissions of road traffic abrasion particles into the ambient air were characterized in the project APART (Abrasion Particles produced by Road Traffic). The project aimed at finding the contribution of the non-exhaust sources to total traffic-related PM10 and PM2.5 for different traffic conditions, by determining specific elemental fingerprint signatures for the various sources. This was achieved by hourly elemental mass concentration measurements in three size classes (2.5-10, 1-2.5 and 0.1-1 micrometers) with a rotating drum impactor (RDI) and subsequent synchrotron radiation X-ray fluorescence spectrometry (SR-XRF). The elemental fingerprint measurements were embedded into a large set of aerosol, gas phase, meteorological and traffic count measurements. To identify traffic related emissions, measurements were performed upwind and downwind of selected roads. For a better investigation of road wear, a road wear simulator was applied in additional experiments. This allows for the identification and quantification of the different source contributions by means of source-receptor modeling, and for the calculation of real-world emission factors for the individual abrasion sources. The preliminary analysis of hourly resolved trace element measurements in a street canyon in Zürich showed

  7. PAGMan - propelled abrasive grit to manage weeds in soybean and corn

    Science.gov (United States)

    New tools for controlling weeds would be useful for soybean and corn production in organic systems or in systems in which weeds developed resistance to multiple herbicides. Here we report on two developments: (i) the safety to soybean seedlings of using air-propelled abrasive grit (PAG) for managing...

  8. Evaluation of Rheological Properties of Gel Abrasive in Magnetic Abrasive Finishing

    Directory of Open Access Journals (Sweden)

    A-Cheng Wang

    2013-01-01

    Full Text Available The purpose of this study was aimed at the evaluation of the mechanism of magnetic finishing with gel abrasive (MFGA, during which the performance of MFGA was compared to that of magnetic abrasive finishing (MAF. Of importance is that MFGA performs better than MAF based on the polishing-efficiency criterion. Silicone gels, however, are semisolid polymer gels with deforming properties that are temperature dependent, ultimately influencing significantly the polishing efficiency in MFGA. Therefore, taking as examples cylindrical rods which were polished using silicone gels with different plasticities to determine the corresponding temperatures of abrasive media in the working area, this study evaluated the MFGA mechanism to elucidate the properties of silicone gels and attain both the finished effect and effective gel abrasives in MFGA to produce a highly efficient polished surface. Next, circulating effects of abrasive media were identified to ensure the efficiency in MFGA and establish the relation between the concentrations of abrasive media and circulating effects in the working area. Experimental results show that silicone gels with low plasticity produce high temperature of abrasive media in MFGA; high temperature of abrasive medium makes excellent circulating effects in the working area, inducing high material removal and fine surface roughness.

  9. Investigations on the trajectories of magnetic abrasive grains in magnetic induction-free abrasive wire sawing

    Science.gov (United States)

    Zhang, Wei; Yao, Chunyan; Tang, Chen; Qiu, Tengwei; Xu, Xuefeng

    2016-12-01

    This study presents a novel method of magnetic induction-free abrasive wire sawing. The ferromagnetic wire is magnetized in a uniform magnetic field, forming a high-gradient magnetic field that separates into paramagnetic and diamagnetic regions. Paramagnetic abrasive grains are attracted to the paramagnetic region and adhere to the wire surface but are repelled from the diamagnetic region. The trajectory of the magnetic abrasive grains is analyzed in a mathematical model and in COMSOL Multiphysics simulations. The results are verified by test investigations on the motions and adsorption of the magnetic abrasive grains using a dynamic microscope system. The detailed grain trajectories are investigated in a numerical model. Because it actively transports grains toward the wire (where they can be transported to the sawing channel), our proposed method achieves more efficient wire sawing performance than traditional free abrasive wire sawing. Such efficient performance is highly sought in silicon wafering technologies, which are commonly used in the solar and semiconductor industries.

  10. Basics of cutting and abrasive processes

    CERN Document Server

    Toenshoff, Hans Kurt

    2013-01-01

    Manufacturing is the basic industrial activity generating real value. Cutting and abrasive technologies are the backbone of precision production in machine, automotive and aircraft building as well as of production of consumer goods. We present the knowledge of modern manufacturing in these technologies on the basis of scientific research. The theory of cutting and abrasive processes and the knowledge about their application in industrial practice are a prerequisite for the studies of manufacturing science and an important part of the curriculum of the master study in German mechanical engineering. The basis of this book is our lecture “Basics of cutting and abrasive processes” (4 semester hours/3 credit hours) at the Leibniz University Hannover, which we offer to the diploma and master students specializing in manufacturing science.

  11. Abrasion test of flexible protective materials on hydraulic structures

    Directory of Open Access Journals (Sweden)

    Xin WANG

    2014-01-01

    Full Text Available In this study, several kinds of flexible protective materials sprayed with polyurea elastomers (hereinafter referred to as polyurea elastomer protective material were adopted to meet the abrasion resistance requirement of hydraulic structures, and their abrasion resistances against the water flow with suspended load or bed load were studied systematically through tests. Natural basalt stones were adopted as the abrasive for simulation of the abrasion effect of the water flow with bed load, and test results indicate that the basalt stone is suitable for use in the abrasion resistance test of the flexible protective material. The wear process of the polyurea elastomer protective material is stable, and the wear loss is linear with the time of abrasion. If the wear thickness is regarded as the abrasion resistance evaluation factor, the abrasion resistance of the 351 pure polyurea is about twice those of pure polyurea with a high level of hardness and aliphatic polyurea, and over five times that of high-performance abrasion-resistant concrete under the abrasion of the water flow with suspended load. It is also about 50 times that of high-performance abrasion-resistant concrete under the abrasion of the water flow with bed load. Overall, the abrasion resistance of pure polyurea presented a decreasing trend with increasing hardness. Pure polyurea with a Shore hardness of D30 has the best abrasion resistance, which is 60 to 70 times that of high-performance abrasion-resistant concrete under the abrasion of the water flow with bed load, and has been recommended, among the five kinds of pure polyurea materials with different hardness, in anti-abrasion protection of hydraulic structures.

  12. Dental Emergencies

    OpenAIRE

    Domb, Ivor

    1982-01-01

    Emergency dental problems can result from trauma, dental pathology, or from dental treatment itself. While the physician can treat many instances of dental trauma, the patient should see a dentist as soon as possible so that teeth can be saved. Emergency treatment of dental pathology usually involves relief of pain and/or swelling. Bleeding is the most frequent post-treatment emergency. The physician should be able to make the patient comfortable until definitive dental treatment can be avail...

  13. Dental Procedures.

    Science.gov (United States)

    Ramponi, Denise R

    2016-01-01

    Dental problems are a common complaint in emergency departments in the United States. There are a wide variety of dental issues addressed in emergency department visits such as dental caries, loose teeth, dental trauma, gingival infections, and dry socket syndrome. Review of the most common dental blocks and dental procedures will allow the practitioner the opportunity to make the patient more comfortable and reduce the amount of analgesia the patient will need upon discharge. Familiarity with the dental equipment, tooth, and mouth anatomy will help prepare the practitioner for to perform these dental procedures.

  14. Performance Enhancement of Abrasive Waterjet Cutting

    NARCIS (Netherlands)

    Vu Ngoc Pi

    2008-01-01

    Abrasive Waterjet (AWJ) Machining is a recent non-traditional machining process. This technology is widely used in industry for cutting difficult-to-machine-materials, milling slots, polishing hard materials etc. AWJ machining has many advantages, e.g. it can cut net-shape parts, no heat is generate

  15. Concrete ice abrasion rig and wear measurements

    NARCIS (Netherlands)

    Shamsutdinova, G.; Rike, P.B.; Hendriks, M.A.N.; Jacobsen, S.

    2015-01-01

    The wear of concrete material due to ice movement is a challenge for offshore and coastal structures. Concrete surfaces exposed to moving ice are subjected to wear at various rates depending on concrete and ice properties. At NTNU, Department of Structural Engineering, concrete ice abrasion phenomen

  16. Evaluation and Treatment of Perioperative Corneal Abrasions

    Directory of Open Access Journals (Sweden)

    Kira L. Segal

    2014-01-01

    Full Text Available Purpose. To evaluate perioperative risk factors for corneal abrasion (CA and to determine current care for perioperative CA in a tertiary care setting. Methods. Hospital-based, cross-sectional study. In Operating Room and Post-Anesthesia Care Units patients, a comparison of cases and controls was evaluated to elucidate risk factors, time to treatment, and most common treatments prescribed for corneal abrasions. Results. 86 cases of corneal abrasion and 89 controls were identified from the 78,542 surgical procedures performed over 2 years. Statistically significant risk factors were age (P=0.0037, general anesthesia (P<0.001, greater average estimated blood loss (P<0.001, eyes taped during surgery (P<0.001, prone position (P<0.001, trendelenburg position (P<0.001, and supplemental oxygen en route to and in the Post-Anesthesia Care Units (P<0.001. Average time to complaint was 129 minutes. 94% of cases had an inpatient ophthalmology consult, with an average time to consult of 164 minutes. The most common treatment was artificial tears alone (40%, followed by combination treatment of antibiotic ointment and artificial tears (35.3%. Conclusions. Trendelenburg positioning is a novel risk factor for CA. Diagnosis and treatment of perioperative corneal abrasions by an ophthalmologist typically require three hours in the tertiary care setting.

  17. 9 CFR 311.14 - Abrasions, bruises, abscesses, pus, etc.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Abrasions, bruises, abscesses, pus... PARTS § 311.14 Abrasions, bruises, abscesses, pus, etc. All slight, well-limited abrasions on the tongue... a carcass which is badly bruised or which is affected by an abscess, or a suppurating sore shall...

  18. [Evaluation of potential risks of abrasive water jet osteotomy in-vivo].

    Science.gov (United States)

    Kuhlmann, C; Pude, F; Bishup, C; Krömer, S; Kirsch, L; Andreae, A; Wacker, K; Schmolke, S

    2005-10-01

    Since the 80's the water jet scalpel is an established tool in some surgical fields. It is used in particular in visceral surgery for preparation of parenchymatous organs. By the addition of biocompatible abrasives, this technique is able to effectively machine hard biological tissues. Free defined cutting geometries can be realised in a non contact process. Therewith this method has crucial advantages compared to conventional osteotomy techniques and gives new impulses to the development in endoprosthetics and correction osteotomies of hollow bones. In the presented work the new developed abrasive water injection jet (AWIJ) was used the first time for in-vivo osteotomies. Aim of this study was the detection of potential thrombembolic effects and wash in effects of the cutting fluid. Hollow bones of the fore and hind leg of 20 house pigs were treated with the new cutting technique. Intraoperative documentation of relevant vital parameters was performed by a multi monitoring system. Thrombembolic effects during the osteotomy were detected by transthoracic Doppler ultrasonography and transesophagale echocardiography. The hollow bones were prepared in consideration of the vascularisation's protection especially in respect to the venous flow. Thrombembolic effects with temporary haemodynamic respectively respiratory consequences could be detected exclusively by using the so called "3-component jet", which consists of 90 vol % of air. The usage of an abrasive suspension enables the airfree dosing of dry soluable abrasives. Thrombembolic effects could not be monitored in this case. Intramedullary fluid in-wash effects as well as resulting electrolytic disorders could not be proven. For abrasive waterjet osteotomies with 3 component jet a relevant risk of thrombembolic effects could be shown. This knowledge has also to be considered for abdominal and neurosurgical applications in the future. Due to the usage of an abrasive suspension this risk can fully be avoided.

  19. Thermal aspects of ice abrasive water jet technology

    Directory of Open Access Journals (Sweden)

    Marko Jerman

    2015-08-01

    Full Text Available During the last few years, different research groups have been developing systems for the transition of abrasive water jet into ice abrasive water jet. The aim of this new technology is to make the technology cleaner from both practical and ecological points of view. Mineral abrasive is replaced with ice grains that melt away after the machining process, leaving the workpiece uncontaminated. Several different approaches to this technology were studied. Thermal aspects of integrating the ice abrasive water jet technology into commercially available machines were considered. The results and analyses of water temperature measurements on the ice abrasive water jet machine are presented in this article.

  20. Usage of abrasion-resistant materials in agriculture

    Directory of Open Access Journals (Sweden)

    J Votava

    2014-06-01

    Full Text Available Agricultural soil-processing machines are subject to an extensive abrasive wear. This paper analyses technical materials and their fitness to exchangeable parts of plough bottoms, such as edge-tools and whole plough cutting edges. There were tested abrasion-resistant steels with different microstructures: austenite, martensite-bainite, and carbide. Steel with the pearlite-ferrite structure was used as an etalon. Abrasion resistance tests were processed in compliance with the norm CSN 01 5084, which is a test of abrasion wear on abrasive cloth.

  1. Properties, structure and machnining capabilities sintered corundum abrasives

    Directory of Open Access Journals (Sweden)

    Cz.J. Niżankowski

    2010-07-01

    Full Text Available The diversity of sintered corundum abrasives used in both bonded and in the embankment of abrasive tools currently poses substantialproblems for their choice of technology to specific tasks. Therefore performed a comparative study of ownership structures and capacitiesof elected representatives machnining sintered corundum abrasives of different generations, and this is normal sintered alumina,submicrocrystalline alumina sintered and nanocrystalline alumina sintered. Were studied some properties of a set of abrasive particles,physicochemical properties and structural and mechanical and technological properties. The studies used the method of microscopicmeasurement to determine the shape of abrasive particles, the pycnometer to determine the density of abrasive, a spectrometer todetermine the chemical composition of the magnetic analyzer for determining the magnetic fraction, scanning electron microscope toanalysis of abrasive grains and a special position to designate the machining capacity abrasive grains. The results showed a significantincrease in machining capacity sintered corundum abrasives with increasing degree of fragmentation of the crystallites sintered corundum abrasives and distinctive bands in the emerging microchip. The originality of the development provides a comparative summary ofproperties of sintered corundum abrasives of different generations and functions obtained by the author making the change in value indexof machininhcapacity grit from cutting speeds for different generations of sintered corundum.

  2. The effect of bleaching on toothbrush abrasion of resin composites

    Directory of Open Access Journals (Sweden)

    Hila Hajizadeh

    2013-01-01

    Full Text Available Aim: This experimental study was designed to focus on the effects of bleaching on toothbrush abrasion in three types of composites with different filler size. Materials and Methods: Forty eight disks were prepared from three types of composite and divided into 6 groups. In the first three groups the abrasion test was done. The remaining groups were bleached and the abrasion test was performed. The weight of the samples before and after abrasion was measured. Statistical analysis was done with one-way ANOVA and Duncan test. Results: There was a significant difference in abrasion of composites with different filler size (P < 0.05. The most amount of abrasion was observed in Z100 after being bleached. An increase in abrasion was noticed in all three types of tested composite after bleaching. Conclusion: According to the findings, it is suggested to use a nano filled resin composite for restoration if the bleaching treatment is required.

  3. INTERNAL FINISHING OF CYLINDRICAL PIPES USING SINTERED MAGNETIC ABRASIVES

    Directory of Open Access Journals (Sweden)

    PALWINDER SINGH

    2011-07-01

    Full Text Available An internal magnetic abrasive finishing (MAF process was proposed to produce highly finished inner surfaces of workpieces used in critical applications. The process principle and the finishing characteristics of magnetic abrasive finishing of cylindrical pipes using sintered magnetic abrasives are described in this research work. Thesintered magnetic abrasive is a mixture of Al2O3 abrasive and ferromagnetic particles. The Al2O3 based sintered magnetic abrasives have been developed in sintering machine. The surface roughness measurements resulting from finishing experiments demonstrate the effects of the abrasive behavior on the surface modifications. Thesurface finish was analysed in terms of percent improvement in surface finish (PISF. Also surface finish was analysed using Response Surface Methodology (RSM. The obtained maximum PISF was 95% and minimum surface roughness was 0.05 μm Ra. To further study the improvement in surface finish, the surface was microscopically examined using X-Ray Diffraction (XRD.

  4. Dental fluorosis in children in areas with fluoride-polluted air, high-fluoride water, and low-fluoride water as well as low-fluoride air: A study of deciduous and permanent teeth in the Shaanxi province, China

    Energy Technology Data Exchange (ETDEWEB)

    Ruan, J.P.; Bardsen, A.; Astrom, A.N.; Huang, R.Z.; Wang, Z.L.; Bjorvatn, K. [University of Bergen, Bergen (Norway). Dept. of Oral Science

    2007-07-01

    The aim of the study was to assess dental fluorosis (DF) in the deciduous and permanent teeth of children in areas with high-F coal (area A) and high-F water (area C) compared to children from area B, with low-F water and coal. DF was found to be prevalent in both dentitions in areas A and C. Similarity in percentages of DF may indicate that indoor air with about to 60 {mu}g F/m{sup 3} and drinking water with 3.6 mg F/L are similarly toxic to developing permanent teeth. The percentage of deciduous teeth with DF was significantly lower in area A compared to area C. Where low-F coal and low-F water were used (area B), similar to 20% of permanent teeth had DF, indicating a relatively low tolerance to fluoride in Chinese children brought up under the present living conditions.

  5. About Dental Amalgam Fillings

    Science.gov (United States)

    ... Medical Procedures Dental Devices Dental Amalgam About Dental Amalgam Fillings Share Tweet Linkedin Pin it More sharing ... I have my fillings removed? What is dental amalgam? Dental amalgam is a dental filling material used ...

  6. Abrasion Resistance Comparison between Rotor and Ring Spun Yarn

    Institute of Scientific and Technical Information of China (English)

    YANG Jian-ping; YU Chong-wen

    2002-01-01

    On the base of literature review and the analysis of yarn properties, yarn structure and some other facts, the abrasion resistance of both rotor spun yarn and ring spun yarns are discussed. The results show that with the same raw material and twist, the rotor spun yarn has lower abrasion resistance than that of ring spun yarn, because of the higher twist employed, the abrasion resistance of rotor spun yarn is higher than that of ring spun yarn.

  7. Thermal aspects of ice abrasive water jet technology

    OpenAIRE

    Marko Jerman; Henri Orbanić; Mihael Junkar; Andrej Lebar

    2015-01-01

    During the last few years, different research groups have been developing systems for the transition of abrasive water jet into ice abrasive water jet. The aim of this new technology is to make the technology cleaner from both practical and ecological points of view. Mineral abrasive is replaced with ice grains that melt away after the machining process, leaving the workpiece uncontaminated. Several different approaches to this technology were studied. Thermal aspects of integrating the ice a...

  8. Thermal aspects of ice abrasive water jet technology

    OpenAIRE

    Orbanić, Henri; Lebar, Andrej; Junkar, Mihael; Jerman, Marko

    2016-01-01

    During the last few years, different research groups have been developing systems for the transition of abrasive water jet into ice abrasive water jet. The aim of this new technology is to make the technology cleaner from both practical and ecological points of view. Mineral abrasive is replaced with ice grains that melt away after the machining process, leaving the workpiece uncontaminated. Several different approaches to this technology were studied. Thermal aspects of integrating the ice a...

  9. Frequency of Iatrogenic damage to adjacent tooth during class II cavity preparation among dental students at Tehran University of Medical Sciences in 2010

    Directory of Open Access Journals (Sweden)

    Reza Yazdani

    2013-08-01

    Full Text Available   Background and Aims: Iatrogenic damage to adjacent tooth during proximal cavity preparation is one of the most common side effects in operative dentistry. The aim of this study was to determine prevalence of iatrogenic damages to adjacent tooth during the preparation of proximal Class II cavities among undergraduate students at dental faculty of Tehran University of Medical Sciences in 2010 .   Materials and Methods: 106 posterior permanent teeth which had Class II decay with sound proximal surfaces of adjacent teeth were selected and restored by dental students awarding the aims of the present study. After finishing restoration, proximal surfaces were completely dried by air and evaluated with dental chair light. In doubtful cases, surfaces were evaluated with × 3 magnification. Damages were classified into 2 groups; abrasion and groove. Data were analyzed using Fishers exact and Pearson chi square tests .   Results: The frequency of adjacent surfaces damage were 57.5%, with 31.1% damages as abrasion and 26.4% as groove. Students who used matrix band and wedge in proximal area as preventive instruments showed 53.4% damages and other students showed 57.3% damages (P>0.05. A significantly higher number of females and students at restorative course level (3 used wedge and matrix band than males and students at restorative course level (4 for protecting adjacent teeth (P<0.05.   Conclusion: According to the high percentage of iatrogenic damages on adjacent sound teeth in class II cavity preparation, teaching of preventive methods and using proper techniques is necessary for dental students as future dentists.

  10. Machining human dentin by abrasive water jet drilling.

    Science.gov (United States)

    Kohorst, Philipp; Tegtmeyer, Sven; Biskup, Christian; Bach, Friedrich-Wilhelm; Stiesch, Meike

    2014-01-01

    The aim of this experimental in-vitro study was to investigate the machining of human dentin using an abrasive water jet and to evaluate the influence of different abrasives and water pressures on the removal rate. Seventy-two human teeth had been collected after extraction and randomly divided into six homogeneous groups (n=12). The teeth were processed in the area of root dentin with an industrial water jet device. Different abrasives (saccharose, sorbitol, xylitol) and water pressures (15 or 25 MPa) were used in each group. Dimensions of dentin removal were analysed using a stripe projection microscope and both drilling depth as well as volume of abrasion were recorded. Morphological analyses of the dentin cavities were performed using scanning electron microscopy (SEM). Both drilling depth and volume of abrasion were significantly influenced by the abrasive and the water pressure. Depending on these parameters, the drilling depth averaged between 142 and 378 μm; the volume of abrasion averaged between 0.07 and 0.15 mm3. Microscopic images revealed that all cavities are spherical and with clearly defined margins. Slight differences between the abrasives were found with respect to the microroughness of the surface of the cavities. The results indicate that abrasive water jet machining is a promising technique for processing human dentin.

  11. The Abrasion-resistance Investigation of Rubberized Concrete

    Institute of Scientific and Technical Information of China (English)

    KANG Jingfu; ZHANG Bo; LI Guangyu

    2012-01-01

    The abrasion resistance properties of rubberized concrete were comparatively studied by taking silica fume and crumb tire rubber as the additives.The abrasion tests were conducted in accordance with the Chinese standard test method DL/T 5150-2001,two recommended test methods:under water method and ring method,were used.The crumb tire rubbers with the sieve size of 8-mesh and 16-mesh were incorporated into the concrete by replacing same volume of sand and as an additive.The abrasion resistance of concrete was evaluated according to the abrasion resistance strength and the mass loss.Test results show that the addition of silica fume enhanced both compressive strength and abrasion resistance of concrete,and the addition of crumb rubber reduced the compressive strength but increased notably the abrasion resistance of the concrete.Silica fume concrete performed a better abrasion resistance than control concrete,and the rubberized concrete performed a much better abrasion resistance than silica fume concrete.The abrasion resistance of rubberized concrete increased with the increase of rubber content.

  12. Influence of number of dental autoclave treatment cycles on rotational performance of commercially available air-turbine handpieces.

    Science.gov (United States)

    Nagai, Masahiro; Takakuda, Kazuo

    2006-06-01

    The influence of number of autoclave treatment cycles (N) on rotational speed and total indicated run-out of commercially available air-turbine handpieces from five manufacturers was investigated at N=0, 50, 100, 150, 200, 250 and 300 cycles, and the significance in the test results was assessed by Dunnett's multiple comparison test. Some air-turbine handpieces showed the significant differences in rotational speed at N=300 cycles, however, the decreases of the rotational speeds were only 1 to 3.5 percent. Some air-turbine handpieces showed the significant differences in total indicated run-out, however, the respective values were smaller than that at N=0 cycle. Accordingly, it can be considered that the ball bearing in the air-turbine handpieces is not affected significantly by autoclave. To further evaluate rotational performance, this study focused on the rotational vibration of the ball bearing components of the air-turbine, as measured by Fast Fourier Transform (FFT) analysis; the power spectra of frequency of the ball's revolution, frequency of the cage's rotation and frequency of the ball's rotation were comparatively investigated at N=0, 150 and 300 cycles, and the influence of autoclave was evaluated qualitatively. No abnormalities in the ball bearings were recognized.

  13. Controlled toothbrush abrasion of softened human enamel.

    Science.gov (United States)

    Voronets, J; Jaeggi, T; Buergin, W; Lussi, A

    2008-01-01

    The aim of this in vitro study was to compare toothbrush abrasion of softened enamel after brushing with two (soft and hard) toothbrushes. One hundred and fifty-six human enamel specimens were indented with a Knoop diamond. Salivary pellicle was formed in vitro over a period of 3 h. Erosive lesions were produced by means of 1% citric acid. A force-measuring device allowed a controlled toothbrushing force of 1.5 N. The specimens were brushed either in toothpaste slurry or with toothpaste in artificial saliva for 15 s. Enamel loss was calculated from the change in indentation depth of the same indent before and after abrasion. Mean surface losses (95% CI) were recorded in ten treatment groups: (1) soft toothbrush only [28 (17-39) nm]; (2) hard toothbrush only [25 (16-34) nm]; (3) soft toothbrush in Sensodyne MultiCare slurry [46 (27-65) nm]; (4) hard toothbrush in Sensodyne MultiCare slurry [45 (24-66) nm]; (5) soft toothbrush in Colgate sensation white slurry [71 (55-87) nm]; (6) hard toothbrush in Colgate sensation white slurry [85 (60-110) nm]; (7) soft toothbrush with Sensodyne MultiCare [48 (39-57) nm]; (8) hard toothbrush with Sensodyne MultiCare [40 (29-51) nm]; (9) soft toothbrush with Colgate sensation white [51 (37-65) nm]; (10) hard toothbrush with Colgate sensation white [52 (36-68) nm]. Neither soft nor hard toothbrushes produced significantly different toothbrush abrasion of softened human enamel in this model (p > 0.05).

  14. Abrasive water jet: a complementary tool

    Directory of Open Access Journals (Sweden)

    Duarte, J. P.

    1998-04-01

    Full Text Available The abrasive water jet is a powerful cutting tool, whose main advantages lie in the absence of thermal effects and the capability of cutting highly thick materials. Compared with Laser, the abrasive water jet allows the cutting of a larger range of thicknesses and a wider variety of materials such as: ornamental stones, metals, polymers, composites, wood, glass and ceramics. The application of this technology has suffered an extensive growth, with successful applications in varied industrial sectors like the automotive, aerospace, textile, metalworking, ornamental stones, etc. The present communication aims at introducing the abrasive water jet as a complementary tool to laser cutting, presenting its advantages by showing some documented examples of pieces cut for different industries.

    O jacto de água abrasivo é uma poderosa ferramenta de corte, tendo como principais vantagens a ausência de processo térmico e permitir o corte de elevadas espessuras. Comparativamente com o laser o jacto de água abrasivo permite cortar uma maior gama de espessuras, e uma maior diversidade de materiais: rochas ornamentais, metais, polimeros, compósitos, madeiras, vidro e cerâmicos. A aplicação desta tecnologia tem sofrido um crescimento acentuado, existindo aplicações de sucesso nos mais variados sectores industriáis como a indústria automóvel, aeroespacial, têxtil, metalomecânica e rochas ornamentáis. Esta comunição pretende apresentar o corte por jacto de agua abrasivo como uma ferramenta de corte complementar ao corte por laser, apresentando as suas vantagens documentadas através de alguns exemplos de peças executadas para as diferentes indústrias.

  15. [Temperature measurements during abrasive water jet osteotomy].

    Science.gov (United States)

    Schmolke, S; Pude, F; Kirsch, L; Honl, M; Schwieger, K; Krömer, S

    2004-01-01

    Working on bone is a major aspect of orthopaedic surgery. Despite its well-known appreciable thermal effects on the edges of the bone cut, the oscillating bone saw blade the oscillating saw remains the standard instrument both for cutting long bones and creating a bed for an endoprosthesis. The application of abrasive water jets offers the possibility of achieving an extremely precise curved cut in bone with no accompanying thermal effect. The thermographically measured absolute temperature increase at the cut edges seen with the water jet was 13 K maximum. The small process forces permit the application in automated handling systems.

  16. Research on Premixed Abrasive Jet Derusting Machine

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The structure, working principles, and main technological parameters of the premajet derusting machineare introduced. Experiments were made to test the relationship among such jet parameters as working pressure,rate of water flow, abrasive weight consistency and derusting efficiency. Reasonable parameters were decided. Re-su lts prove that the derusting machine is characterized by its high derusting efficiency (as high as 20 m2/h), goodderusting quality (as good as ISO8501-1 Sa 2.5), and low specific power consumption (about 0.3 kW · h/m2).Therefore it is a new type of high efficiency derusting machine.

  17. Diamond-Fluoroplastic Composites for Abrasive Tools

    Science.gov (United States)

    Adrianova, O. A.; Kirillin, A. D.; Chersky, I. N.

    2001-07-01

    Composite materials based on polytetrafluoroethylene (PTFE) and natural technical diamond powders from Yakutia diamond deposits are developed. It is shown that the compositions based on PTFE and a technical diamond powder at a content of up to 60 wt.%, due to their good physicomechanical characteristics, low friction coefficient, and good wetting of diamond particles by polymer, make is possible to create abrasive tools for polishing and grinding hard metals and semiprecious and precious stones with high serviceability and operational life combined with a considerable increase in the quality of treated surfaces and operational stability of the tools. It is found that PTFE, being a more elastic and softer matrix than the traditional ones, exhibits a self-sharpening effect of diamond grains upon grinding hard surfaces, when the grains go deep into the elastic matrix, the matrix wears out, and the working part of the tool becomes enriched with the diamond powder. These conclusions are confirmed by electron microscopic investigations. It is shown that the introduction of ultradisperse fillings (up to 2 wt.%) into such compositions allows us to improve the characteristics of abrasive tools considerably, especially for grinding hard semiprecious stones. The physicomechanical and frictional characteristics of the compositions and specific examples of their application in the jewelry industry and in stone working are discussed.

  18. Effects of different lasers and particle abrasion on surface characteristics of zirconia ceramics.

    Directory of Open Access Journals (Sweden)

    Sakineh Arami

    2014-04-01

    Full Text Available The aim of this study was to assess the surface of yttrium-stabilized tetragonal zirconia (Y-TZP after surface treatment with lasers and airborne-particle abrasion.First, 77 samples of presintered zirconia blocks measuring 10 × 10 × 2 mm were made, sintered and polished. Then, they were randomly divided into 11 groups (n=7 and received surface treatments namely, Er:YAG laser irradiation with output power of 1.5, 2 and 2.5 W, Nd:YAG laser with output power of 1.5, 2 and 2.5 W, CO2 laser with output power of 3, 4 and 5 W, AL2O3 airborne-particle abrasion (50μ and no treatment (controls. Following treatment, the parameters of surface roughness such as Ra, Rku and Rsk were evaluated using a digital profilometer and surface examination was done by SEM.According to ANOVA and Tukey's test, the mean surface roughness (Ra after Nd:YAG laser irradiation at 2 and 2.5 W was significantly higher than other groups. Roughness increased with increasing output power of Nd:YAG and CO2 lasers. Treated surfaces by Er:YAG laser and air abrasion showed similar surface roughness. SEM micrographs showed small microcracks in specimens irradiated with Nd:YAG and CO2 lasers.Nd:YAG laser created a rough surface on the zirconia ceramic with many microcracks; therefore, its use is not recommended. Air abrasion method can be used with Er:YAG laser irradiation for the treatment of zirconia ceramic.

  19. Minimal alterations on the enamel surface by micro-abrasion: in vitro roughness and wear assessments

    Directory of Open Access Journals (Sweden)

    Marcela Charantola Rodrigues

    2013-04-01

    Full Text Available Objective: To evaluate the in vitro changes on the enamel surface after a micro-abrasion treatment promoted by different products. Material and Methods: Fifty (50 fragments of bovine enamel (15 mm × 5 mm were randomly assigned to five groups (n=10 according to the product utilized: G1 (control= silicone polisher (TDV, G2= 37% phosphoric acid (3M/ESPE + pumice stone (SS White, G3= Micropol (DMC Equipment, G4= Opalustre (Ultradent and G5= Whiteness RM (FGM Dental Products. Roughness and wear were the responsible variables used to analyze these surfaces in four stages: baseline, 60 s and 120 s after the micro-abrasion and after polishing, using a Hommel Tester T1000 device. After the tests, a normal distribution of data was verified, with repeated ANOVA analyses (p≤0.05 which were used to compare each product in different stages. One-way ANOVA and Tukey tests were applied for individual comparisons between the products in each stage (p≤0.05. Results: Means and standard deviations of roughness and wear (µm after all the promoted stages were: G1=7.26(1.81/13.16(2.67, G2=2.02(0.62/37.44(3.33, G3=1.81(0.91/34.93(6.92, G4=1.92(0.29/38.42(0.65 and G5=1.98(0.53/33.45(2.66. At 60 seconds, all products tended to produce less surface roughness with a variable gradual decrease over time. After polishing, there were no statistically significant differences between the groups, except for G1. Independent of the product utilized, the enamel wear occurred after the micro-abrasion. Conclusions: In this in vitro study, enamel micro-abrasion presented itself as a conservative approach, regardless of the type of the paste compound utilized. These products promoted minor roughness alterations and minimal wear. The use of phosphoric acid and pumice stone showed similar results to commercial products for the micro-abrasion with regard to the surface roughness and wear.

  20. Abrasion Resistant Refractory Materials GB/T 23294-2009

    Institute of Scientific and Technical Information of China (English)

    Yu Lingyuan

    2009-01-01

    @@ 1 Scope This standard specifies the definition, classification, technical requirements, test methods, quality appraisal procedure, packing, marking, transportation, storage, and quality certificate of abrasion resistant refractory materials. This standard is applicable to abrasion resistant refractory materials for circulating fluidized bed boilers, daily waste incinerator, industrial waste incinerator, medical waste incinerator, ordinary solid waste incinerator, hazardous waste incinerator, etc.

  1. A Finite Element Approach to Modeling Abrasive Wear Modes

    NARCIS (Netherlands)

    Woldman, M.; Heide, van der E.; Tinga, T.; Masen, M.A.

    2016-01-01

    Machine components operating in sandy environments will wear because of the abrasive interaction with sand particles. In this work, a method is derived to predict the amount of wear caused by such abrasive action, in order to improve the maintenance concept of the components. A finite element model

  2. Testing of Commercial Cutting Heads for Abrasive Water Jet Technology

    OpenAIRE

    Klich, J. (Jiří); Hlaváček, P.; M. Zeleňák; Sitek, L. (Libor); Foldyna, J. (Josef)

    2013-01-01

    Five different cutting heads designed for cutting by high-speed abrasive water jet technology were tested from cutting ability point of view. Straight kerfs were cut in several metal materials by abrasive water jet. Material removal volume was determined as a measure of performance of specific cutting head. Quality of cutting surface was observed, too. Results are compared and discussed.

  3. Research and development of blasting abrasive made of steelmaking slag

    Institute of Scientific and Technical Information of China (English)

    TANG Oujing

    2015-01-01

    This study focuses on the development of a new type of nonmetallic steelmaking slag abrasive.The performance,processing,and application of steelmaking slag as a nonmetallic abrasive are introduced.The chemical composition,hardness,crushing value,and particle gradation of steelmaking slag are analyzed.A processing method for steelmaking slag as a blasting abrasive is suggested and evaluated.Compared with conventional abrasives such as copper ore sand and cast iron shot,processed steelmaking slag exhibits similar performance and can satisfy abrasive technical requirements.The derusting effect provided by steelmaking slag for a ship deck can reach the Sa2.0 level,and its recyclability is higher than that of copper ore sand.The derusting performance of steelmaking slag is similar to that of copper ore,and it can thus be used in repairing ship decks.

  4. Abrasive wear behaviour of as cast and austempered ductile irons

    Energy Technology Data Exchange (ETDEWEB)

    Baydogan, M.; Koekden, M.U.; Cimenoglu, H. [Istanbul Technical Univ., Dept. of Metallurgy and Materials Science Engineering Istanbul (Turkey)

    2000-07-01

    In this study, abrasive wear behaviour of as cast and austempered GGG 50 and GGG 80 quality ductile irons was investigated. In the as cast condition, GGG 50 and GGG 80 quality ductile irons were having ferritic and pearlitic matrix structures, respectively. Austempering at 250 C after austenitisation at 900 C for 100 minutes produced bainitic matrix structure in both of the investigated ductile irons. Abrasive wear tests performed by rubbing the as cast and austempered specimens on Al{sub 2}O{sub 3} abrasive bands, revealed that austempering treatment improves abrasion resistance about 10-70% depending on the abrasive particle size and composition of the base iron. In the as cast condition, pearlitic GGG 80 grade ductile iron, has higher wear resistance than ferritic GGG 50 grade ductile iron. In the austempered condition GGG 50 and GGG 80 grade ductile irons which have bainitic matrix structure, exhibit almost similar wear resistance. (orig.)

  5. Hydro-abrasive erosion: Problems and solutions

    Science.gov (United States)

    Winkler, K.

    2014-03-01

    The number of hydro power plants with hydro-abrasive erosion is increasing worldwide. An overall approach is needed to minimize the impact of this phenomenon. Already at the start of the planning phase an evaluation should be done to quantify the erosion and the impact on the operation. For this, the influencing parameters and their impact on the erosion have to be known. The necessary information for the evaluation comprises among others the future design, the particle parameters of the water, which will pass the turbine, and the power plant owner's framework for the future operation like availability or maximum allowable efficiency loss, before an overhaul needs to be done. Based on this evaluation of the erosion, an optimised solution can then be found, by analysing all measures in relation to investments, energy production and maintenance costs as decision parameters. Often a more erosion-resistant design, instead of choosing the turbine design with the highest efficiency, will lead to higher revenue. The paper will discuss the influencing parameters on hydro-abrasive erosion and the problems to acquire this information. There are different optimisation possibilities, which will be shown in different case studies. One key aspect to reduce the erosion and prolong the operation time of the components is to coat all relevant parts. But it is very important that this decision is taken early in the design stage, as the design has to be adapted to the requirements of the coating process. The quality of coatings and their impact on the operation will be discussed in detail in the paper as due to the non-availability of standards many questions arise in projects.

  6. Survey on microorganism contamination in air of dental clinic in a hospital%某部医院口腔科门诊空气微生物污染状况的调查

    Institute of Scientific and Technical Information of China (English)

    曹巧玲; 杨凯; 金世富; 潘朝阳; 王京

    2013-01-01

    目的 了解口腔科门诊空气中的微生物分布,以便更好地指导临床消毒工作,预防医院感染.方法 对某部医院口腔科门诊环境中空气污染细菌与真菌的含量进行检测,选择门诊高峰期后30 min,采用平板沉降法采集口腔科的空气样本,普通营养琼脂平板培养后计数菌落、革兰染色及分离鉴定进行判断分析.结果 口腔科空气中污染微生物以细菌为主,空气中细菌总数符合国家卫生标准.革兰染色结果表明,口腔科门诊室空气中细菌大多数为革兰阳性菌,占细菌总数的83.26%.口腔科门诊空气中的真菌含量较多.其中牙周科含菌量最高,达525个/m3空气.致病菌分离出3株葡萄球菌和2株乙型溶血性链菌.结论 口腔科门诊患者多,流动性大,各种急慢性感染性疾病的患者均在一般患者中间就诊,因此,提示需要进一步加强对口腔科门诊环境的消毒,以控制医院感染的发生及流行.%[Objective]To understand the distribution of microorganisms in air of dental clinic, provide the basis for guiding the clinical disinfection and preventing the nosocomial infection. [ Methods] The contents of bacteria and fungi in air of dental clinic in a hospital were detected. The air samples were collected by the flat sedimentation method at 30 minutes after visiting peak. After the ordinary nutrient agar plate culture, the colony counting, Gram's staining, isolation and identification were performed for analysis. [Results]The main microorganism of air pollution in dental clinic was bacteria, and the total bacteria count in air met the national health standards. The Crams staining showed that the bacteria in air of dental clinic mainly were Gram-positive bacteria, accounting for 83.26% of total bacteria count. The content of fungi in air of dental clinic was high. The content of microorganism in department of periodontology was the highest, which reached 525/m3. 3 strains of Staphylococcus and 2

  7. Effect of abrasive grit size on wear of manganese-zinc ferrite under three-body abrasion

    Science.gov (United States)

    Miyoshi, Kazuhisa

    1987-01-01

    Wear experiments were conducted using replication electron microscopy and reflection electron diffraction to study abrasion and deformed layers produced in single-crystal Mn-Zn ferrites under three-body abrasion. The abrasion mechanism of Mn-Zn ferrite changes drastically with the size of abrasive grits. With 15-micron (1000-mesh) SiC grits, abrasion of Mn-Zn ferrite is due principally to brittle fracture; while with 4- and 2-micron (4000- and 6000-mesh) SiC grits, abrasion is due to plastic deformation and fracture. Both microcracking and plastic flow produce polycrystalline states on the wear surfaces of single-crystal Mn-Zn ferrites. Coefficient of wear, total thickness of the deformed layers, and surface roughness of the wear surfaces increase markedly with an increase in abrasive grit size. The total thicknesses of the deformed layers are 3 microns for the ferrite abraded by 15-micron SiC, 0.9 microns for the ferrite abraded by 4-micron SiC, and 0.8 microns for the ferrite abraded by 1-micron SiC.

  8. New Rock Abrasivity Test Method for Tool Life Assessments on Hard Rock Tunnel Boring: The Rolling Indentation Abrasion Test (RIAT)

    Science.gov (United States)

    Macias, F. J.; Dahl, F.; Bruland, A.

    2016-05-01

    The tunnel boring machine (TBM) method has become widely used and is currently an important presence within the tunnelling industry. Large investments and high geological risk are involved using TBMs, and disc cutter consumption has a great influence on performance and cost, especially in hard rock conditions. Furthermore, reliable cutter life assessments facilitate the control of risk as well as avoiding delays and budget overruns. Since abrasive wear is the most common process affecting cutter consumption, good laboratory tests for rock abrasivity assessments are needed. A new abrasivity test method by rolling disc named Rolling Indentation Abrasion Test (RIAT) has been developed. The goal of the new test design and procedure is to reproduce wear behaviour on hard rock tunnel boring in a more realistic way than the traditionally used methods. Wear by rolling contact on intact rock samples is introduced and several rock types, covering a wide rock abrasiveness range, have been tested by RIAT. The RIAT procedure indicates a great ability of the testing method to assess abrasive wear on rolling discs. In addition and to evaluate the newly developed RIAT test method, a comprehensive laboratory testing programme including the most commonly used abrasivity test methods and the mineral composition were carried out. Relationships between the achieved results from conventional testing and RIAT results have been analysed.

  9. Abrasion Properties of Steel Fiber Reinforced Silica Fume Concrete According to Los Angeles and Water Abrasion Tests

    Directory of Open Access Journals (Sweden)

    Tsan-Ching CHENG

    2014-12-01

    Full Text Available The current study mainly investigated the influence of different tests on the abrasion resistance of concrete mixed with steel fibers and silica fume. The abrasion resistance was assessed at 28, 56 and 91 days on concretes with water-binder ratios of 0.35 and 0.55 where in some mixes silica fume was substituted by 5 % of cement by weight. Steel fibers of 0.5 % and 1.0 % of concrete volume were also added into the test concrete by replacement of coarse and fine aggregates. The results showed that concrete with higher compressive strength in Los Angeles abrasion tests also had better abrasion resistance. The inclusion of steel fibers into test concrete with a water-binder ratio of 0.35 resulted in a significant increase in compressive strength. This concrete also displayed better abrasion resistance and splitting tensile strength than reference concrete; in the test sample with a water-binder ratio of 0.55, the added steel fibers was unable to effectively produce cementation with the concrete. The inclusion of silica fume improved the abrasion resistance of concretes. In water abrasion testing, the abrasion resistance of concrete containing steel fiber was worse than that of concrete without steel fibers. In the water abrasion testing, the surface of steel fiber reinforced concrete was eroded by water and steel balls, and the impact caused the steel fibers to separate from the concrete and led to higher wear loss. DOI: http://dx.doi.org/10.5755/j01.ms.20.4.6460

  10. Refractory, Abrasive, and Other Industrial Minerals Operations - Direct Download

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This map layer includes refractory, abrasive, and other industrial minerals operations in the United States. The data represent commodities covered by the Minerals...

  11. Anti-abrasive nanocoatings current and future applications

    CERN Document Server

    2015-01-01

    This book provides an overview of the fabrication methods for anti-abrasive nanocoatings. The connections among fabrication parameters, the characteristics of nanocoatings and the resulting properties (i.e. nanohardness, toughness, wear rate, load-bearing ability, friction coefficient, and scratch resistance) are discussed. Size-affected mechanical properties of nanocoatings are examined, including their uses. Anti-abrasive nanocoatings, including metallic-, ceramic-, and polymeric-based layers, as well as different kinds of nanostructures, such as multi-layered nanocomposites and thin films, are reviewed. * Provides a comprehensive overview of the fabrication methods for anti-abrasive nanocoatings* Discusses the connections among fabrication parameters, the characteristics of nanocoatings and the resulting properties* Reviews advantages and drawbacks of fabrication methods for anti-abrasive nanocoatings and clarifies the place of these nanocoatings in the world of nanotechnology

  12. An Investigation of Different Material on Abrasive Water jet Machine

    Directory of Open Access Journals (Sweden)

    Vaibhav.j.limbachiya

    2011-07-01

    Full Text Available Abrasive water jet machine (AWJM is a nontraditional machining process. Abrasive water jet machining is a process of removal of material by impact erosion of high pressure (1500-4000 bar, high velocity of water and entrained high velocity of grit abrasives on a work piece. It’s a non-conventional machining process. At herefirst works on theoretical work after it make some experimental work and then analyses both results. Theoretical MRR found equal to the experimental MRR. In this paper investigation for three different materials like en8,acrylic and aluminum is carried out using Taguchi design of experiment method. Experiments are carried out using L25 Orthogonal array by varying Material traverse speed and abrasive mass flow rate for each material respectively. Anova carried out for identifies significant parameters.

  13. [Dependence of the dentinal abrasion of human teeth on their microhardness].

    Science.gov (United States)

    Remizov, S M; Pruzhanskiĭ, L Iu

    1989-01-01

    The dentin resistance against abrasion was studied as related to its microhardness. Sections of 15 intact teeth were investigated (central upper incisors). Water suspensions (40% weight-to weight) of dicalcium phosphate (DCP, FRG; and DKF-1 and DKF-2, USSR) were used as abrasives. Dentin microhardness was measured with a PMT-3 device, and abrasion assessed with profilographic technique. Dentin abrasion was related to its microhardness and to the kind of abrasive used. Dentin abrasion increased as its microhardness decreased. DCF showed minimal abrasive effect, DKF-2 had maximal effect with DKF-1 keeping the intermediate position.

  14. A review of micro-scale abrasion testing

    Energy Technology Data Exchange (ETDEWEB)

    Gant, A J; Gee, M G [Electronics and Modelling Group, Division of Industry and Innovation, Module 9, Space G9-A5, Queens Road, Teddington, Middlesex, TW11 0LW (United Kingdom)

    2011-02-23

    Micro-scale abrasion (commonly referred to as 'ball cratering') is a small-scale tribological test method which can be operated on a desktop. It offers the possibility of providing a quick, cheap, localized abrasion test that can be used with small samples. In principle its operation is simple, but in practice there are issues with wear scar measurement, wear mode and its applicability to a wide variety of monolithic materials and coatings. (topical review)

  15. Dental OCT

    Science.gov (United States)

    Wilder-Smith, Petra; Otis, Linda; Zhang, Jun; Chen, Zhongping

    This chapter describes the applications of OCT for imaging in vivo dental and oral tissue. The oral cavity is a diverse environment that includes oral mucosa, gingival tissues, teeth and their supporting structures. Because OCT can image both hard and soft tissues of the oral cavity at high resolution, it offers the unique capacity to identity dental disease before destructive changes have progressed. OCT images depict clinically important anatomical features such as the location of soft tissue attachments, morphological changes in gingival tissue, tooth decay, enamel thickness and decay, as well as the structural integrity of dental restorations. OCT imaging allows for earlier intervention than is possible with current diagnostic modalities.

  16. Experiments of Applying the Rare-Earth Modifying Agents in New Dental Materials Preparation

    Institute of Scientific and Technical Information of China (English)

    Chen Xiaohu; Wang Hua; Wang Qin; Li Xiaodi; Ma Rui

    2007-01-01

    Harmless rare-earth modifying agents were prepared by orthogonal experiments. A new resin material was synthesized with the qualities such as rigidity, rubbing abrasion, aging, luster and plasticity better than the dental resin materials in common used. It could be used as the substitutes for the applied resin teeth materials.

  17. Dental sealants

    Science.gov (United States)

    ... few quick steps. There is no drilling or scraping of the molars. Your dentist will: Clean the ... Dental sealants. Updated October 19, 2016. ADA.org Web site. www.ada.org/en/member-center/oral- ...

  18. Infant dental care (image)

    Science.gov (United States)

    ... sugar water. As the child grows, establishing proper dental hygiene will promote healthy teeth and gums which are essential to overall good health. Poor dental development, dental disease, and dental trauma can result ...

  19. Etiology and pathogenesis of dental erosion.

    Science.gov (United States)

    Kanzow, Philipp; Wegehaupt, Florian J; Attin, Thomas; Wiegand, Annette

    2016-04-01

    The condition of dental erosion is defined as acid-related loss of tooth structure which does not involve microorganisms. Depending on the origin of the acid, extrinsic (usually caused by acids in food) and intrinsic (caused by endogenous acid) erosion can be distinguished. The presence and severity of erosive defects depend on various parameters such as nutrition, saliva, general diseases, and mechanical stress by abrasion and attrition. As an example, dietary habits which involve frequent intake of acidic food and beverages, occupational acid exposure, as well as certain drugs or diseases that affect saliva flow rate are accompanied by an increased risk of erosive dental hard tissue defects. By a thorough clinical examination and an accurate anamnesis, various erosion-related risk factors can be identified and strategies to reduce or eliminate these factors be identified.

  20. System Design of Continuous Feeding Abrasive for Pre-mixed Abrasive Jet and Its Experiment%前混合磨料射流新型连续加砂系统设计与实验

    Institute of Scientific and Technical Information of China (English)

    左伟芹; 卢义玉; 夏彬伟; 刘勇; 葛兆龙

    2013-01-01

    Pre-mixed abrasive water jets have high capabilities on machining hard materials, such as rock,metal,ceramics etc. However,it is difficult to popularize this technology extensively,due to its inconsecutive abrasive feeding process. To address this problem, a novel abrasive feeding system was put forward in this paper. In this system, a jet pump can add abrasive to two tanks and the tanks are controlled by air-operated valves to supply abrasive to the main pipe line in turn. The results of the separate tests to the jet pump indicated the optimal distance between throat and orifice was 1. 5d1 and the density of the abrasive had very few influence on the entrainment process. The experiment on the whole system with an abrasive jets nozzle of 3mm in diameter also was conducted. Under the operating parameter with the pressure of 20MPa and the abrasive mass concentration of 8% , the test consumed 200kg abrasive with the duration of 30min by switching over between tow tanks 4 times. Hence, It is proved that the novel pre-mixed abrasive water jets system can meet the practical requirement appropriately and has great potential application value.%前混合磨料射流连续加砂难以实现,大大降低了工作效率,制约了该技术的推广运用.针对这一问题,提出在系统中并联两个磨料罐,运用气动闸阀实现磨料罐在加砂、供料两个状态间切换,运用射流泵自行加砂,为前混合磨料射流连续加砂提供新思路.对该系统的主要部件——射流泵进行实验研究,得出吸砂时最优喉嘴距为1.5d1左右,表明引射物的密度对射流泵最优喉嘴距影响较小;用直径为3mm的喷嘴在20MPa压力、8%磨料浓度下进行了30min的实验,共消耗4罐磨料,实现了前混合磨料射流的连续加砂;根据实验条件计算每罐磨料所使用的时间,调整两磨料罐状态切换的间隔时间即可实现不同实验条件下的连续加砂.

  1. Dental Calculus Arrest of Dental Caries

    Science.gov (United States)

    Keyes, Paul H.; Rams, Thomas E.

    2016-01-01

    Background An inverse relationship between dental calculus mineralization and dental caries demineralization on teeth has been noted in some studies. Dental calculus may even form superficial layers over existing dental caries and arrest their progression, but this phenomenon has been only rarely documented and infrequently considered in the field of Cariology. To further assess the occurrence of dental calculus arrest of dental caries, this study evaluated a large number of extracted human teeth for the presence and location of dental caries, dental calculus, and dental plaque biofilms. Materials and methods A total of 1,200 teeth were preserved in 10% buffered formal saline, and viewed while moist by a single experienced examiner using a research stereomicroscope at 15-25× magnification. Representative teeth were sectioned and photographed, and their dental plaque biofilms subjected to gram-stain examination with light microscopy at 100× magnification. Results Dental calculus was observed on 1,140 (95%) of the extracted human teeth, and no dental carious lesions were found underlying dental calculus-covered surfaces on 1,139 of these teeth. However, dental calculus arrest of dental caries was found on one (0.54%) of 187 evaluated teeth that presented with unrestored proximal enamel caries. On the distal surface of a maxillary premolar tooth, dental calculus mineralization filled the outer surface cavitation of an incipient dental caries lesion. The dental calculus-covered carious lesion extended only slightly into enamel, and exhibited a brown pigmentation characteristic of inactive or arrested dental caries. In contrast, the tooth's mesial surface, without a superficial layer of dental calculus, had a large carious lesion going through enamel and deep into dentin. Conclusions These observations further document the potential protective effects of dental calculus mineralization against dental caries. PMID:27446993

  2. Superficial characterization of titanium league when submitted to abrasive blasting; Caracterizacao superficial de titanio liga ao ser submetido a tratamento de jateamento

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, L.Y.; Leite, I.V.; Szesz, E.M.; Siqueira, C.J.M., E-mail: lsuzuki@neoortho.com.b [Universidade Federal do Parana (UFPR), Curitiba, PR (Brazil)

    2010-07-01

    Commercially pure titanium and some of its alloys exhibit a good biocompatibility. These characteristics are frequently used in the manufacture of orthopedic and dental implants. It is possible to modify its surface making it the bioactive using various methods, such as deposition of hydroxyapatite by plasma spray and increasing the roughness of the surface by abrasive blasting. This work is to modify the surface of titanium alloy Ti6Al4V ELI (ASTM F136: 02a) for abrasive blasting and study the morphology, crystallographic phases and the mechanical characteristics of the surface obtained. For such purpose, SEM images, diffraction of X-rays and tests of risk produced by nanoindenter. The sandblasting was done using alumina powder and blasting time of 6s. The morphology of the surfaces of Ti6Al4V ELI changed after sandblasting with increased roughness. It is possible to conclude that after sandblasting the titanium surface do not have a ductile behavior. (author)

  3. Polishing of dental porcelain by polycrystalline diamond.

    Science.gov (United States)

    Nakamura, Yoshiharu; Sato, Hideaki; Ohtsuka, Masaki; Hojo, Satoru

    2010-01-01

    Polycrystalline diamond (PCD) exhibits excellent abrasive characteristics and is commonly used as loose grains for precision machining of hard ceramics and other materials that are difficult to grind and polish. In the present study, we investigated using bonded PCD for polishing dental porcelain, for which a lustrous surface is difficult to obtain by polishing. We compared the surface texture and characteristics of dental porcelain after polishing with bonded PCD with that obtained using bonded monocrystalline diamond (MCD), which is commonly used for this purpose. Polishing was performed at various pressures and rotational speeds on a custom-built polishing apparatus using bonded PCD or MCD with grain sizes of 3.92 μm on specimens consisting of VITA Omega 900 dentin porcelain after firing and then glazing to a specified surface roughness. The surface roughness of the polished porcelain and the abrasion quantity in terms of its polishing depth were measured, and its surface texture and characteristics were investigated. At low polishing pressures, PCD yielded a finer polished surface than MCD. The polishing depth after polishing for 20-30 min was approximately 2-3 μm with PCD and 1-2 μm with MCD. The polished surface was more uniform and smooth with PCD than with MCD.

  4. Comminution of Mica by Cavitation Abrasive Water Jet

    Institute of Scientific and Technical Information of China (English)

    GUO Chu-wen; LIU Lin-sheng; HAN Dong-tai; LI Ai-min; ZHANG Dong-hai

    2003-01-01

    The comminution of mica with an abrasive water jet is mainly based on three knids of effects, that is, high-speed collision, cavitating effect and shearing effect. Cavitation abrasive water jet was applied for the comminution of mica because cavitation abrasive water jet can make full use of the three effects mentioned above. Besides high speed impacting among particles,cavitation and shearing were also enhanced due to the divergent angle at the outlet of the cavitation nozzle.A JME-200CX transmission electron microscope was used for observing the size distribution of particles.Variance analysis on the experimental results indicates that the effect of cavitation is much more significant than that of collision.The effect of pressure on comminution results becomes less with the decrease of the particle size.

  5. Design and manufacturing of abrasive jet machine for drilling operation

    Directory of Open Access Journals (Sweden)

    Mittal Divyansh

    2016-01-01

    Full Text Available Wide application of Abrasive Jet Machine (AJM is found in machining hard and brittle materials. Machining of brittle materials by AJM is due to brittle fracture and removal of micro chips from the work piece. Embedment of the abrasive particles in the brittle materials results in decrease of machining efficiency. In this paper design and manufacturing of AJM has been presented. Various parts of AJM have been designed using ANSYS 16.2 software. The parts are then manufactured indigenously as per designed parameters. The machine fabricated in this work will be used further for process optimization of AJM parameters for machining of glass and ceramics.

  6. Dental Wear: A Scanning Electron Microscope Study

    Directory of Open Access Journals (Sweden)

    Luca Levrini

    2014-01-01

    Full Text Available Dental wear can be differentiated into different types on the basis of morphological and etiological factors. The present research was carried out on twelve extracted human teeth with dental wear (three teeth showing each type of wear: erosion, attrition, abrasion, and abfraction studied by scanning electron microscopy (SEM. The study aimed, through analysis of the macro- and micromorphological features of the lesions (considering the enamel, dentin, enamel prisms, dentinal tubules, and pulp, to clarify the different clinical and diagnostic presentations of dental wear and their possible significance. Our results, which confirm current knowledge, provide a complete overview of the distinctive morphology of each lesion type. It is important to identify the type of dental wear lesion in order to recognize the contributing etiological factors and, consequently, identify other more complex, nondental disorders (such as gastroesophageal reflux, eating disorders. It is clear that each type of lesion has a specific morphology and mechanism, and further clinical studies are needed to clarify the etiological processes, particularly those underlying the onset of abfraction.

  7. Healing effect of Sodium-Sucrose-Octasulfate and EGF on epithelial corneal abrasions in rabbits

    DEFF Research Database (Denmark)

    Johansen, Sven; Heegaard, Steffen; Bjerrum, Kirsten Birgitte;

    1998-01-01

    ophthalmology, Sjögrens syndrome, cornea, abrasion, epidermal growth factor, sodium-sucrose-octasulfate......ophthalmology, Sjögrens syndrome, cornea, abrasion, epidermal growth factor, sodium-sucrose-octasulfate...

  8. Abrasion Properties of Steel Fiber Reinforced Silica Fume Concrete According to Los Angeles and Water Abrasion Tests

    OpenAIRE

    Tsan-Ching CHENG; Cheng, An; Ran HUANG; Lin, Wei-Ting

    2014-01-01

    The current study mainly investigated the influence of different tests on the abrasion resistance of concrete mixed with steel fibers and silica fume. The abrasion resistance was assessed at 28, 56 and 91 days on concretes with water-binder ratios of 0.35 and 0.55 where in some mixes silica fume was substituted by 5 % of cement by weight. Steel fibers of 0.5 % and 1.0 % of concrete volume were also added into the test concrete by replacement of coarse and fine aggregates. The results showed t...

  9. Exposure to crystalline silica in abrasive blasting operations where silica and non-silica abrasives are used.

    Science.gov (United States)

    Radnoff, Diane L; Kutz, Michelle K

    2014-01-01

    Exposure to respirable crystalline silica is a hazard common to many industries in Alberta but particularly so in abrasive blasting. Alberta occupational health and safety legislation requires the consideration of silica substitutes when conducting abrasive blasting, where reasonably practicable. In this study, exposure to crystalline silica during abrasive blasting was evaluated when both silica and non-silica products were used. The crystalline silica content of non-silica abrasives was also measured. The facilities evaluated were preparing metal products for the application of coatings, so the substrate should not have had a significant contribution to worker exposure to crystalline silica. The occupational sampling results indicate that two-thirds of the workers assessed were potentially over-exposed to respirable crystalline silica. About one-third of the measurements over the exposure limit were at the work sites using silica substitutes at the time of the assessment. The use of the silica substitute, by itself, did not appear to have a large effect on the mean airborne exposure levels. There are a number of factors that may contribute to over-exposures, including the isolation of the blasting area, housekeeping, and inappropriate use of respiratory protective equipment. However, the non-silica abrasives themselves also contain silica. Bulk analysis results for non-silica abrasives commercially available in Alberta indicate that many contain crystalline silica above the legislated disclosure limit of 0.1% weight of silica per weight of product (w/w) and this information may not be accurately disclosed on the material safety data sheet for the product. The employer may still have to evaluate the potential for exposure to crystalline silica at their work site, even when silica substitutes are used. Limited tests on recycled non-silica abrasive indicated that the silica content had increased. Further study is required to evaluate the impact of product recycling

  10. Shore plartform abrasion in a para-periglacial environment, Galicia, northwestern Spain

    OpenAIRE

    2007-01-01

    [EN] The Schmidt Rock Test Hammer was used to study the effect of abrasion on shore platforms in Galicia, northwestern Spain. On platforms where tidally-induced weathering (salt, wetting and drying, etc.) is dominant, rock strength is significantly lower than in areas where abrasion is, or has been active in the recent past. This suggests that abrasion removes weathered surface material, exposing the stronger, less weathered rock below. Abrasion downwearing, measured with a transverse micro-e...

  11. Dental Training Films.

    Science.gov (United States)

    Veterans Administration Medical Center, Washington, DC.

    This dental training films catalog is organized into two sections. Section I is a category listing of the films by number and title, indexed according to generalized headings; categories are as follow: anatomy, articulator systems, complete dentures, dental assisting, dental laboratory technology, dental materials, dental office emergencies,…

  12. Measurements of traffic-induced abrasion particles in a Swiss city

    Science.gov (United States)

    Furger, M.; Amato, F.; Bukowiecki, N.

    2009-04-01

    Particle emissions from road traffic can be divided into two basic categories: i) emissions due to fuel combustion, ii) emissions due to abrasion and mechanical wear of the brakes, the engine, the tires, and the road surface. The three-year project APART was focused on the latter, and measurements took place mainly in the city of Zurich, Switzerland. Several campaigns on and in the vicinity of roads with different traffic characteristics were performed between 2006 and 2008, covering different seasons and weather conditions. Air-borne, deposited and re-suspended particles were collected at fixed locations and with a mobile laboratory, and subsequently chemically analyzed. Vehicle abrasion particles consisted mainly of Fe, Cu, Mo, Sn, Sb and Ba. Road dust samples were composed mainly of organic and elemental carbon and some crustal elements (Si, Ca, Fe, Al, K, Mg), with traces of Cu, Zn, Ba, and Ti. The transport distance of the particles was investigated with aerodynamic particle sizer (APS) measurements at varying distances from a freeway. Furthermore the dependence of re-suspension on traffic density was investigated. This study was funded by the Swiss Federal Roads Authority (ASTRA), the Swiss Federal Office for the Environment (BAFU), and by the Spanish Ministry of Science and Innovation (GRACCIE-SCD2007-00067).

  13. Numerical study of agglomerate abrasion in a tumbling mixer

    NARCIS (Netherlands)

    Thanh Nguyen, [No Value; Willemsz, Tofan; Frijlink, Henderik; Maarschalk, Kees van der Voort

    2014-01-01

    A numerical simulation using the Discrete Element Method (DEM) was performed to investigate the phenomena concerning the abrasion and breakage of agglomerates in a diffusion powder mixer. Agglomerates were created by defining a single structure of particles with bonds of different strengths using th

  14. Protective effect of green tea on dentin erosion and abrasion

    Directory of Open Access Journals (Sweden)

    Melissa Thiemi Kato

    2009-12-01

    Full Text Available OBJECTIVE: This in situ study evaluated the protective effect of green tea on dentin erosion (ERO and erosion-abrasion (ABR. MATERIAL AND METHODS: Ten volunteers wore intraoral palatal appliances with bovine dentin specimens subjected to ERO or ERO + toothbrushing abrasion performed immediately (ERO+I-ABR or 30 min after erosion (ERO+30-min-ABR. During 2 experimental 5-day crossover phases, the volunteers rinsed with green tea or water (control, 1 min between each erosive (5 min, cola drink and abrasive challenge (30 s, toothbrushing, 4x/day. Dentin wear was measured by profilometry. RESULTS: The green tea reduced the dentin wear significantly for all conditions compared to control. ERO+I-ABR led to significantly higher wear than ERO, but it was not significantly different from ERO+30-min-ABR. ERO+30-min-ABR provoked significant higher wear than ERO, only for the placebo treatment. CONCLUSIONS: From the results of the present study, it may be concluded that green tea reduces the dentin wear under erosive/abrasive conditions.

  15. Abrasive blasting agents: designing studies to evaluate relative risk.

    Science.gov (United States)

    Hubbs, Ann; Greskevitch, Mark; Kuempel, Eileen; Suarez, Fernando; Toraason, Mark

    Workers exposed to respirable crystalline silica used in abrasive blasting are at increased risk of developing a debilitating and often fatal fibrotic lung disease called silicosis. The National Institute for Occupational Safety and Health (NIOSH) recommends that silica sand be prohibited as abrasive blasting material and that less hazardous materials be used in blasting operations. However, data are needed on the relative risks associated with exposure to abrasive blasting materials other than silica. NIOSH has completed acute studies in rats (Hubbs et al., 2001; Porter et al., 2002). To provide dose-response data applicable to making recommendation for occupational exposure limits, NIOSH has collaborated with the National Toxicology Program (NTP) to design longer term studies with silica substitutes. For risk assessment purposes, selected doses will include concentrations that are relevant to human exposures. Rat lung burdens achieved should be comparable to those estimated in humans with working lifetime exposures, even if this results in "overloading" doses in rats. To quantify both dose and response, retained particle burdens in the lungs and lung-associated lymph nodes will be measured, as well as biochemical and pathological indices of pulmonary response. This design will facilitate assessment of the pulmonary fibrogenic potential of inhaled abrasive blasting agents at occupationally relevant concentrations.

  16. 29 CFR 1926.303 - Abrasive wheels and tools.

    Science.gov (United States)

    2010-07-01

    ... Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Tools-Hand and Power § 1926.303 Abrasive wheels and tools. (a) Power. All grinding machines shall be supplied with sufficient power to maintain...

  17. Review of Artificial Abrasion Test Methods for PV Module Technology

    Energy Technology Data Exchange (ETDEWEB)

    Miller, David C. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Muller, Matt T. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Simpson, Lin J. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-08-01

    This review is intended to identify the method or methods--and the basic details of those methods--that might be used to develop an artificial abrasion test. Methods used in the PV literature were compared with their closest implementation in existing standards. Also, meetings of the International PV Quality Assurance Task Force Task Group 12-3 (TG12-3, which is concerned with coated glass) were used to identify established test methods. Feedback from the group, which included many of the authors from the PV literature, included insights not explored within the literature itself. The combined experience and examples from the literature are intended to provide an assessment of the present industry practices and an informed path forward. Recommendations toward artificial abrasion test methods are then identified based on the experiences in the literature and feedback from the PV community. The review here is strictly focused on abrasion. Assessment methods, including optical performance (e.g., transmittance or reflectance), surface energy, and verification of chemical composition were not examined. Methods of artificially soiling PV modules or other specimens were not examined. The weathering of artificial or naturally soiled specimens (which may ultimately include combined temperature and humidity, thermal cycling and ultraviolet light) were also not examined. A sense of the purpose or application of an abrasion test method within the PV industry should, however, be evident from the literature.

  18. Gears castings from ductile iron of improved abrasion wear resistance

    Directory of Open Access Journals (Sweden)

    D. Kopyciński

    2011-10-01

    Full Text Available The aim of this study was to develop an industrial technological process for the manufacturing of castings from alloyed ductile iron characterized by improved resistance to abrasion wear. The outcome of the study was the implementation of developed technology under the industrial conditions of ASPAMET Foundry Plant and start up of production of a wide range of cast gears.

  19. Electrical resistivity measurements to predict abrasion resistance of rock aggregates

    Indian Academy of Sciences (India)

    Sair Kahraman; Mustafa Fener

    2008-04-01

    The prediction of Los Angeles (LA) abrasion loss from some indirect tests is useful for practical applications. For this purpose, LA abrasion, electrical resistivity, density and porosity tests were carried out on 27 different rock types. LA abrasion loss values were correlated with electrical resistivity and a good correlation between the two parameters was found. To see the effect of rock class on the correlation, regression analysis was repeated for igneous rocks, metamorphic rocks and sedimentary rocks, respectively. It was seen that correlation coefficients were increased for the rock classes. In addition, the data were divided into two groups according to porosity and density, respectively. After repeating regression analysis for these porosity and density groups, stronger correlations were obtained compared to the equation derived for all rocks. The validity of the derived equations was statistically tested and it was shown that all derived equations were significant. Finally, it can be said that all derived equations can alternatively be used for the estimation of LA abrasion loss from electrical resistivity.

  20. Brushing abrasion of luting cements under neutral and acidic conditions.

    Science.gov (United States)

    Buchalla, W; Attin, T; Hellwig, E

    2000-01-01

    Four resin based materials (Compolute Aplicap, ESPE; Variolink Ultra, Vivadent; C&B Metabond, Parkell and Panavia 21, Kuraray), two carboxylate cements (Poly-F Plus, Dentsply DeTrey and Durelon Maxicap, ESPE), two glass-ionomer cements (Fuji I, GC and Ketac-Cem Aplicap, ESPE), one resin-modified glass ionomer cement (Vitremer, 3M) one polyacid-modified resin composite (Dyract Cem, Dentsply DeTrey) and one zinc phosphate cement (Harvard, Richter & Hoffmann) were investigated according to their brushing resistance after storage in neutral and acidic buffer solutions. For this purpose 24 cylindrical acrylic molds were each filled with the materials. After hardening, the samples were stored for seven days in 100% relative humidity and at 37 degrees C. Subsequently, they were ground flat and polished. Then each specimen was covered with an adhesive tape leaving a 4 mm wide window on the cement surface. Twelve samples of each material were stored for 24 hours in a buffer solution with a pH of 6.8. The remaining 12 samples were placed in a buffer with a pH of 3.0. All specimens were then subjected to a three media brushing abrasion (2,000 strokes) in an automatic brushing machine. Storage and brushing were performed three times. After 6,000 brushing strokes per specimen, the tape was removed. Brushing abrasion was measured with a computerized laser profilometer and statistically analyzed with ANOVA and Tukey's Standardized Range Test (p < or = 0.05). The highest brushing abrasion was found for the two carboxylate cements. The lowest brushing abrasion was found for one resin based material, Compolute Aplicap. With the exception of three resin-based materials, a lower pH led to a higher brushing abrasion.

  1. Wear characterization of abrasive waterjet nozzles and nozzle materials

    Science.gov (United States)

    Nanduri, Madhusarathi

    Parameters that influence nozzle wear in the abrasive water jet (AWJ) environment were identified and classified into nozzle geometric, AWJ system, and nozzle material categories. Regular and accelerated wear test procedures were developed to study nozzle wear under actual and simulated conditions, respectively. Long term tests, using garnet abrasive, were conducted to validate the accelerated test procedure. In addition to exit diameter growth, two new measures of wear, nozzle weight loss and nozzle bore profiles were shown to be invaluable in characterizing and explaining the phenomena of nozzle wear. By conducting nozzle wear tests, the effects of nozzle geometric, and AWJ system parameters on nozzle wear were systematically investigated. An empirical model was developed for nozzle weight loss rate. To understand the response of nozzle materials under varying AWJ system conditions, erosion tests were conducted on samples of typical nozzle materials. The effect of factors such as jet impingement angle, abrasive type, abrasive size, abrasive flow rate, water pressure, traverse speed, and target material was evaluated. Scanning electron microscopy was performed on eroded samples as well as worn nozzles to understand the wear mechanisms. The dominant wear mechanism observed was grain pullout. Erosion models were reviewed and along the lines of classical erosion theories a semi-empirical model, suitable for erosion of nozzle materials under AWJ impact, was developed. The erosion data correlated very well with the developed model. Finally, the cutting efficiency of AWJ nozzles was investigated in conjunction with nozzle wear. The cutting efficiency of a nozzle deteriorates as it wears. There is a direct correlation between nozzle wear and cutting efficiency. The operating conditions that produce the most efficient jets also cause the most wear in the nozzle.

  2. Loose abrasive lapping hardness of optical glasses and its interpretation.

    Science.gov (United States)

    Lambropoulos, J C; Xu, S; Fang, T

    1997-03-01

    We present an interpretation of the lapping hardness of commercially available optical glasses in terms of a micromechanics model of material removal by subsurface lateral cracking. We analyze data on loose abrasive microgrinding, or lapping at fixed nominal pressure, for many commercially available optical glasses in terms of this model. The Schott and Hoya data on lapping hardness are correlated with the results of such a model. Lapping hardness is a function of the mechanical properties of the glass: The volume removal rate increases approximately linearly with Young's modulus, and it decreases with fracture toughness and (approximately) the square of the Knoop hardness. The microroughness induced by lapping depends on the plastic and elastic properties of the glass, depending on abrasive shape. This is in contrast to deterministic microgrinding (fixed infeed rate), where it is determined from the plastic and fracture properties of the glass. We also show that Preston's coefficient has a similar dependence as lapping hardness on glass mechanical properties, as well as a linear dependence on abrasive size for the case of brittle material removal. These observations lead to the definition of an augmented Preston coefficient during brittle material removal. The augmented Preston coefficient does not depend on glass material properties or abrasive size and thus describes the interaction of the glass surface with the coolant-immersed abrasive grain and the backing plate. Numerical simulations of indentation are used to locate the origin of subsurface cracks and the distribution of residual surface and subsurface stresses, known to cause surface (radial) and subsurface (median, lateral) cracks.

  3. Testing Dietary Hypotheses of East African Hominines Using Buccal Dental Microwear Data

    Science.gov (United States)

    Martínez, Laura Mónica; Estebaranz-Sánchez, Ferran; Galbany, Jordi

    2016-01-01

    There is much debate on the dietary adaptations of the robust hominin lineages during the Pliocene-Pleistocene transition. It has been argued that the shift from C3 to C4 ecosystems in Africa was the main factor responsible for the robust dental and facial anatomical adaptations of Paranthropus taxa, which might be indicative of the consumption of fibrous, abrasive plant foods in open environments. However, occlusal dental microwear data fail to provide evidence of such dietary adaptations and are not consistent with isotopic evidence that supports greater C4 food intake for the robust clades than for the gracile australopithecines. We provide evidence from buccal dental microwear data that supports softer dietary habits than expected for P. aethiopicus and P. boisei based both on masticatory apomorphies and isotopic analyses. On one hand, striation densities on the buccal enamel surfaces of paranthropines teeth are low, resembling those of H. habilis and clearly differing from those observed on H. ergaster, which display higher scratch densities indicative of the consumption of a wide assortment of highly abrasive foodstuffs. Buccal dental microwear patterns are consistent with those previously described for occlusal enamel surfaces, suggesting that Paranthropus consumed much softer diets than previously presumed and thus calling into question a strict interpretation of isotopic evidence. On the other hand, the significantly high buccal scratch densities observed in the H. ergaster specimens are not consistent with a highly specialized, mostly carnivorous diet; instead, they support the consumption of a wide range of highly abrasive food items. PMID:27851745

  4. Dental Holography

    Science.gov (United States)

    Dirtoft, Ingegerd

    1983-12-01

    Ten years have passed since the first articles appeared in this new field. The qualities of the laser light together with the need of contactless 3-D measurements for different dental purposes seemed to be extremely promising, but still just a few scientists have used the method and mostly for laboratory studies. For some reason there has been a preponderance for orthodontic measurements. This seems to be a bit peculiar from holographic view compared with measurements for engineering purposes, which usually are made on metals. So naturally holography can become a clinical tool for measurements in the field of fixed bridges, removable partial dentures and implants. One of the problems is that the need for holography in dental research must be fulfilled in collaboration with physicists. Only a two-way communication during an entire experiment can balance both technical and odontological demands and thus give practical and clinical important results. The need for an easy way of handling the evaluation to get all required information is another problem and of course the holographic equipment must be converted to a box easy to handle for everyone. At last the position of dental holography today is going to be carefully examined together with an attempt to look into the hopefully exciting and not to utopic future for this research field.

  5. Danish dental education:

    DEFF Research Database (Denmark)

    Moore, Rod

    1985-01-01

    The effects of Danish cultural traditions on dental education in Denmark are described, as well as the system's current structure and developing issues. Some Danish ideas for future exports of dental education programs and dental personnel are also discussed.......The effects of Danish cultural traditions on dental education in Denmark are described, as well as the system's current structure and developing issues. Some Danish ideas for future exports of dental education programs and dental personnel are also discussed....

  6. MECHANISM AND PREDICTION OF MATERIAL ABRASION IN HIGH-VELOCITY SEDIMENT-LADEN FLOW

    Institute of Scientific and Technical Information of China (English)

    HUANG Xi-bin; YUAN Yin-zhong

    2006-01-01

    The wall surface of material is prone to silt abrasion by high-velocity sediment-laden flow. The silt abrasion is different form cavitation erosion. In this article, the characteristics of silt abrasion were discussed. The mechanism of silt abrasion was analyzed and the formation and development of ripple shape on wall surface of material were explained thereafter. Based on turbulence theory and test data, some formulas were derived for predicting the abrasion rate of concrete wall surface in high-velocity sediment-laden flow. The calculated results show good agreement with the experimental data.

  7. American Dental Hygienists' Association

    Science.gov (United States)

    ... Health Student Resources National Exam Student Advisor Resources Dental Hygiene Programs Scholarships and Grants Research Center Transforming Dental Hygiene Education Advocacy Practice Issues Direct Access Scope of ...

  8. Dental students--dental advocates.

    Science.gov (United States)

    Bensch, Brittany

    2010-01-01

    Student advocacy and involvement in the political process is built into the structure of the American Student Dental Association (ASDA), especially in its Legislative Grassroots Network and an internal communication network among students to ensure political awareness. Students are concerned with such issues as a universally accepted, non-patient-based licensure process, mid-level providers, loan availability and tax deductibility, financial support for schools, and service early in one's professional career (giving forward rather than giving back). Through collaboration with the American Dental Education Association and with many state associations, students participate in lobbying, awareness campaigns, and behind the scenes as legislative aids. Although students share the same love for the profession that animates established practitioners, they are perceived by legislators as being different. Students are involved in the legislative process because it represents their future.

  9. Abrasive Wear Study of NiCrFeSiB Flame Sprayed Coating

    Science.gov (United States)

    Sharma, Satpal

    2013-10-01

    In the present study, abrasive wear behavior of NiCrFeSiB alloy coating on carbon steel was investigated. The NiCrFeSiB coating powder was deposited by flame spraying process. The microstructure, porosity and hardness of the coatings were evaluated. Elemental mapping was carried out in order to study the distribution of various elements in the coating. The abrasive wear behavior of these coatings was investigated under three normal loads (5, 10 and 15 N) and two abrasive grit sizes (120 and 320 grit). The abrasive wear rate was found to increase with the increase of load and abrasive size. The abrasive wear resistance of coating was found to be 2-3 times as compared to the substrate. Analysis of the scanning electron microscope images revealed cutting and plowing as the material removal mechanisms in these coatings under abrasive wear conditions used in this investigation.

  10. Estudo in vitro da abrasividade de dentifrícios In vitro study of dentifrice abrasivity

    Directory of Open Access Journals (Sweden)

    Antonio Carlos Canabarro ANDRADE JUNIOR

    1998-07-01

    Full Text Available O objetivo do presente estudo é avaliar a abrasividade de 15 dentifrícios, utilizando o aparelho Einlehner AT 1000. Uma solução contendo 50 g de cada creme dental mais 800 ml de água destilada era colocada no referido aparelho, que promovia 174.000 rotações da haste metálica, com um cilindro descartável de borracha, sobre uma tela de cobre pesada previamente (P1, por 100 minutos. Com o término da operação, a tela era lavada, seca e novamente pesada (P2. Através da equação: (P1-P2 ÷ 3,07 x 10-4 encontrava-se o número de gramas/metro2. Cada dentifrício foi testado 3 vezes e o valor final apresentado é a média dos 3 testes. Adicionalmente foram investigados o pH e o teor de sólidos das diferentes marcas. Os resultados mostraram que os dentifrícios possuem uma grande variação no grau de abrasão. As 3 marcas mais abrasivas foram: Close Up com flúor, Colgate Antitártaro e Oral B Dentes e Gengivas, as duas primeiras com dióxido de silício. As 3 marcas menos abrasivas foram: Colgate M.F.P. com cálcio, Gessy com flúor e Signal com flúor, todas com carbonato de cálcio. Os dentifrícios Close Up com flúor, Kolynos Ação Total e Oral B Dentes e Gengivas apresentaram um pH abaixo de 7, que pode indicar um possível efeito erosivo, associado à abrasão. Novas pesquisas são necessárias para comparar esses resultados com cremes dentais internacionais.The aim of the present study was to determine the abrasivity of 15 dentifrices, using Einlehner AT 1000 equipment. A solution containing 50 g of dentifrice and 800 ml of distilled water was placed in the equipment, at 174.000 revolutions of the metal stem, with a disposable rubber cylinder on a previously weighed copper screen (P1, for 100 min. After the procedure was over, the screen was washed, dried, and weighed again (P2. The number of g/m2 was found by using the equation: (P1-P2 ÷ 3,07 x 10-4. Each dentifrice was tested three times, and the final value was the average of

  11. Pattern of dental diseases among patients attending outpatient department of dental: a hospital based cross-sectional study

    Directory of Open Access Journals (Sweden)

    Pitamber Datt Garkoti

    2015-06-01

    Full Text Available Introduction: The public health problems associated with oral disease are a serious burden in India and other countries of the world. The causes of oral diseases are primarily rooted in poor socioeconomic and physical environment; unhealthy lifestyles and oral health related behaviour accordingly the action towards improvement of oral health should be directed towards modification of unhealthy environment and behaviours. Objective: To know the pattern of dental diseases among the patients attending Dental OPD. Materials and Methods: A hospital based cross sectional study among patients attending dental OPD in a tertiary care centre of Kumaun region during a period of one year i.e. from 1st January 2012 to 31st December 2012. Results: A total of 8928 patients attended dental OPD. Majority of the patients (25.3% were in the age group 30-39 years. Mostly were males (51.54%. Most common disease was dental caries (54.54%, followed by gingivitis (37.62%, abrasion (3.82%, malocclusion (3.05%, pericoronitis (0.53% and jaw fracture (0.44%. Conclusion: Dental Caries was the most common disease. Majority of the patients were in 30-39 years of age group. Health education and awareness at school level and in the community might prevent tooth loss in later life. [Natl J Med Res 2015; 5(2.000: 112-115

  12. A physically-based abrasive wear model for composite materials

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Gun Y.; Dharan, C.K.H.; Ritchie, Robert O.

    2001-05-01

    A simple physically-based model for the abrasive wear of composite materials is presented based on the mechanics and mechanisms associated with sliding wear in soft (ductile) matrix composites containing hard (brittle) reinforcement particles. The model is based on the assumption that any portion of the reinforcement that is removed as wear debris cannot contribute to the wear resistance of the matrix material. The size of this non-contributing portion of the reinforcement is estimated by modeling the three primary wear mechanisms, specifically plowing, interfacial cracking and particle removal. Critical variables describing the role of the reinforcement, such as its relative size and the nature of the matrix/reinforcement interface, are characterized by a single contribution coefficient, C. Predictions are compared with the results of experimental two-body (pin-on drum) abrasive wear tests performed on a model aluminum particulate-reinforced epoxy matrix composite material.

  13. Optimization of Abrasive Water Jet Cutting of Ductile Materials

    Institute of Scientific and Technical Information of China (English)

    Asif IQBAL; Naeem U DAR; Ghulam HUSSAIN

    2011-01-01

    Full factorial design of experiments was developed in order to investigate the effects of jet pressure, abrasive mixing rate, cutting feed, and plate thickness upon three response variables, surface finish of cutting wear zone, percentage proportion of striation free area, and maximum width of cut. The set of sixteen experiments was performed on each of the following two ductile materials: AISI 4340 (high strength low alloy steel, hardened to 49HRc) and Aluminum 2219. Analysis of Variance (ANOVA) was performed on experimental data in order to determine the significance of effects of different parameters on the performance measures. It was found that cutting feed and thickness were highly influential parameters, while abrasive mixing rate is influential upon surface roughness only. Strong interaction was found between jet pressure and workpiece material.Multi-criteria numerical optimization was performed in order to simultaneously maximize/minimize different combinations of performance measures.

  14. Nanometric Finishing on Biomedical Implants by Abrasive Flow Finishing

    Science.gov (United States)

    Subramanian, Kavithaa Thirumalai; Balashanmugam, Natchimuthu; Shashi Kumar, Panaghra Veeraiah

    2016-01-01

    Abrasive flow finishing (AFF) is a non-conventional finishing technique that offers better accuracy, efficiency, consistency, economy in finishing of complex/difficult to machine materials/components and provides the possibility of effective automation as aspired by the manufacturing sector. The present study describes the finishing of a hip joint made of ASTM grade Co-Cr alloy by Abrasive Flow Machining (AFM) process. The major input parameters of the AFF process were optimized for achieving nanometric finishing of the component. The roughness average (Ra) values were recorded during experimentation using surface roughness tester and the results are discussed in detail. The surface finished hip joints were characterized using Scanning Electron Microscopy (SEM), Atomic Force Microscopy (AFM) and residual stress analysis using X-Ray Diffraction (XRD). The discussion lays emphasis on the significance, efficacy and versatile nature of the AFF process in finishing of bio-medical implants.

  15. Abrasion Testing of Critical Components of Hydrokinetic Devices

    Energy Technology Data Exchange (ETDEWEB)

    Worthington, Monty [ORPC Alaska; Ali, Muhammad [Ohio University; Ravens, Tom [University of Alaska Anchorage

    2013-12-06

    The objective of the Abrasion Testing of Critical Components of Hydrokinetic Devices (Project) was to test critical components of hydrokinetic devices in waters with high levels of suspended sediment – information that is widely applicable to the hydrokinetic industry. Tidal and river sites in Alaska typically have high suspended sediment concentrations. High suspended sediment also occurs in major rivers and estuaries throughout the world and throughout high latitude locations where glacial inputs introduce silt into water bodies. In assessing the vulnerability of technology components to sediment induced abrasion, one of the greatest concerns is the impact that the sediment may have on device components such as bearings and seals, failures of which could lead to both efficiency loss and catastrophic system failures.

  16. Investigation of Noise Level and Penetration Rate of Pneumatic Drill vis-à-vis Rock Compressive Strength and Abrasivity

    Science.gov (United States)

    Kivade, S. B.; Murthy, Ch. S. N.; Vardhan, H.

    2014-10-01

    In this paper, detailed studies were carried out to determine the influence of rock properties on the sound level produced during pneumatic drilling. Further, investigation was also carried out on the effect of thrust, air pressure and compressive strength on penetration rate and the sound level produced. For this purpose, a fabricated pneumatic drill set up available in the institute was used. Rock properties, like compressive strength and abrasivity, of various samples collected from the field were determined in the laboratory. Drilling experiments were carried out on ten different rock samples for varying thrust and air pressure values and the corresponding A-weighted equivalent continuous sound levels were measured. It was observed that, very low thrust results in low penetration rate. Even very high thrust does not produce high penetration rate at higher operating air pressures. With increase in thrust beyond the optimum level, the penetration rate starts decreasing and causes the drill bit to `stall'. Results of the study show that penetration rate and sound level increases with increase in the thrust level. After reaching the maximum, they start decreasing despite the increase of thrust. The main purpose of the study is to develop a general prediction model and to investigate the relationships between sound level produced during drilling and physical properties such as uniaxial compressive strength and abrasivity of sedimentary rocks. The results were evaluated using the multiple regression analysis taking into account the interaction effects of predictor variables.

  17. Influence of finishing on the electrochemical properties of dental alloys.

    Science.gov (United States)

    Kaneko, T; Hattori, M; Hasegawa, K; Yoshinari, M; Kawada, E; Oda, Y

    2000-05-01

    Dental alloy surface finishing procedures of may influence their electrochemical behavior, which is used to evaluate their corrosion resistance. We examined the polarization resistance and potentiodynamic polarization profile of the precious-metal alloys, Type 4 gold alloy and silver-palladium alloy, and the base-metal alloys, nickel-chromium alloy, cobalt-chromium alloy, and CP-titanium. Three types of finishing procedure were examined: mirror-finishing using 0.05 micron alumina particles, polishing using #600 abrasive paper and sandblasting. Dissolution of the alloy elements in 0.9% NaCl solution was also measured and compared with the electrochemical evaluation. The corrosion resistance of the dental alloys was found to relate to finishing as follows: The polarization resistance and potentiodynamic polarization behavior revealed that the corrosion resistance improved in the order of sandblasting, #600-abrasive-paper polishing, and mirror-finishing. While the corrosion potential, critical current density and passive current density varied depending on the type of finishing, the transpassive potential remained unchanged. The influence of finishing on the corrosion resistance of precious-metal alloys was less significant than on that of base-metal alloys. A mirror-finishing specimen was recommended for use in evaluation of the corrosion resistance of various dental alloys.

  18. Microstructure formation and properties of abrasion resistant cast steel

    OpenAIRE

    S. Parzych; Krawczyk, J.

    2010-01-01

    The so-called adamitic cast steels are characterised by a high abrasion resistance. These cast steels are of a pearlitic matrix with uniformly distributed hypereutectoid cementite precipitates. Apart from hypereutectoid cementite very often transformed ledeburite also occurs in the microstructure of these cast steels. Such cast steels contain chromium (app. 1 %) and nickel (app. 0.5 %) as alloy additions and sometimes their silicon content is increased. The presence of molybdenum is also perm...

  19. Surface characterization of current composites after toothbrush abrasion.

    Science.gov (United States)

    Takahashi, Rena; Jin, Jian; Nikaido, Toru; Tagami, Junji; Hickel, Reinhard; Kunzelmann, Karl-Heinz

    2013-01-01

    The present study was designed to evaluate the surface roughness and the gloss of current composites before and after toothbrush abrasion. We assessed forty dimensionally standardized composite specimens (n=8/group) from five composites: two nanohybrids (i. e., IPS Empress Direct Enamel and IPS Empress Direct Dentin), two microhybrids (i. e., Clearfil AP-X and Filtek Z250) and one organically modified ceramics (Admira). All of the specimens were polished with 4000-grid silicon carbide papers. Surface roughness was measured with a profilometer and gloss was measured with a glossmeter before and after powered toothbrush abrasion with a 1:1 slurry (dentifrice/tap water) at 12,000 strokes in a toothbrush simulator. There was a significant increase in the surface roughness and a reduction in gloss after toothbrush abrasion in all of the composites except Clearfil AP-X (p<0.05). Simple regression analysis showed that there was not an association between the surface roughness and the gloss (R(2)=0.191, p<0.001).

  20. Development of underwater cutting system by abrasive water-jet

    Science.gov (United States)

    Demura, Kenji; Yamaguchi, Hitoshi

    1993-09-01

    The technology to cut objects in the ocean's depths with abrasive water jets was examined for possible application in view of the greater water depths and sophistication involved in work on the ocean floor today. A test model was developed to study this technology's safety and practicability. The test model was designed for use at great water depths and has functions and a configuration that are unlike equipment used on land. A continuous, stable supply of abrasive is a distinctive design feature. In land applications, there had been problems with plugged tubes and an uneven supply. For this reason, the abrasive was converted to slurry form, and a continuous pressurized tube pump system was adopted for supply to the nozzle head. Also, a hydraulic motor that does not employ oil or electric power was used to provide an underwater drive that is environment-friendly. The report outlines the technology's general design concept including its distinctive functions and its configuration for use at great depths, and the report provides great detail on the equipment.

  1. Correlation Between Particle Velocities and Conditions of Abrasive Waterjet Formation

    Science.gov (United States)

    Chen, Wei-Long

    1990-01-01

    The velocities of water and abrasive particles in abrasive waterjet(AWJ) were measured by the use of Laser Transit Anemometer(LTA). A setup for the velocity measurement was constructed and a statistical technique was used to improve the accuracy of the velocity determination. A comparison of the magnitude of velocities determined by LTA, Piezoelectric Force Transducer and Schlieren Photograph clearly indicates the feasibility of the use of LTA. The velocities of water and particles were measured for different diameters of water and slurry nozzles, abrasive mass flow rates and particle sizes. The performed experiments enabled us to evaluate the effects of conditions of jet formation on the particles velocities. An empirical equation for the prediction of particles velocities was constructed by the use of obtained results. The coefficient of correlation between experimental and computed results is equal to 0.93. The acquired information can be used to select the operational parameters in AWJ cutting. The obtained results also provide information on the acceleration mechanism of entrained particles, which may be used to improve the design of slurry nozzle.

  2. Characterization of Effective Parameters in Abrasive Waterjet Rock Cutting

    Science.gov (United States)

    Oh, Tae-Min; Cho, Gye-Chun

    2014-03-01

    The rock cutting performance of an abrasive waterjet is affected by various parameters. In this study, rock cutting tests are conducted with different energy (i.e., water pressure, traverse speed, and abrasive feed rate), geometry (i.e., standoff distance), and material parameters [i.e., uniaxial compressive strength (UCS)]. In particular, experimental tests are carried out at a long standoff distance (up to 60 cm) to consider field application. The effective parameters of the rock cutting process are identified based on the relationships between the cutting performance indices (depth, width, and volume) and parameters. In addition, the cutting efficiency is analyzed with effective parameters as well as different pump types and the number of cutting passes considering the concept of kinetic jet energy. Efficiency analysis reveals that the cutting depth efficiency tends to increase with an increase in the water pressure and traverse speed and with a decrease in the standoff distance and UCS. Cutting volume efficiency strongly depends on standoff distance. High efficiency of cutting volume is obtained at a long standoff distance regardless of the pump type. The efficiency analysis provides a realistic way to optimize parameters for abrasive waterjet rock excavation.

  3. Shotcup petal abrasions in close range .410-caliber shotgun injuries.

    Science.gov (United States)

    Dowling, G P; Dickinson, J A; Cooke, C T

    1988-01-01

    Shotcup petal abrasions centered around a shotgun wound of entrance are generally thought to occur at a range of 30 to 90 cm. A suicidal .410-caliber shotgun injury of the right eye is described in which typical petal abrasions were noted around the entrance wound. However, significant soot deposition around the wound suggested that the range of fire was less than 30 cm and perhaps closer to 15 cm. Test-firing of the weapon and ammunition used by the decedent showed some spread of the shotcup petals at a range of 7.5 cm, progressing to maximum spread at 30 to 52.5 cm. Further testing with other .410 ammunition, containing shotcups, confirmed the spread of shotcup petals at ranges less than 30 cm, irrespective of manufacturer, shotshell length, and birdshot size. When a variety of shotguns were tested, it was found that one weapon with a very short barrel and cylinder bore did not exhibit petal spread until a range of 30 cm was reached. The remaining shotguns, with longer barrels and full choke, all demonstrated definite petal spread at a range of 12.5 cm. The long, narrow configuration of .410 shotcup petals may explain their early spread and the production of petal abrasions at ranges of less than 30 cm.

  4. Child Indicators: Dental Health.

    Science.gov (United States)

    Lewit, Eugene M.; Kerrebrock, Nancy

    1998-01-01

    Reviews measures of dental health in children and the evidence on child dental health. Although children's dental health has improved over the past two decades, many poor children do not receive necessary dental health services, and reasons for this failure are summarized. (SLD)

  5. American Dental Education Association

    Science.gov (United States)

    ... applicant. ... Learn more ADEA DHCAS Applicants The ADEA Dental Hygiene Centralized Application Service (DHCAS®) is the centralized applic... Learn more ADEA DHCAS Program Directors For programs interested in participating... Learn more ... Publications & Data Official Guide to Dental Schools Bulletin of Dental Education Journal of Dental ...

  6. Weaker dental enamel explains dental decay.

    Science.gov (United States)

    Vieira, Alexandre R; Gibson, Carolyn W; Deeley, Kathleen; Xue, Hui; Li, Yong

    2015-01-01

    Dental caries continues to be the most prevalent bacteria-mediated non-contagious disease of humankind. Dental professionals assert the disease can be explained by poor oral hygiene and a diet rich in sugars but this does not account for caries free individuals exposed to the same risk factors. In order to test the hypothesis that amount of amelogenin during enamel development can influence caries susceptibility, we generated multiple strains of mice with varying levels of available amelogenin during dental development. Mechanical tests showed that dental enamel developed with less amelogenin is "weaker" while the dental enamel of animals over-expressing amelogenin appears to be more resistant to acid dissolution.

  7. The oral health in Precolombian Peru before - The dental caries in the Precolombian epoch befare -

    OpenAIRE

    2014-01-01

    There havent been made much investigación work this item our intention in this article is give an approach about the considerations and conclusions of them The pre Columbian Peruvian habitant was afected, gum descases, abrasion, etc. Dental caries affected the litoral habitante more than Andean habitant due to the different geographic regiens show diverse exogenic factors such as climate, diet, uses. As we go through in time and the pre colombian cultures got more development, also caries sus...

  8. Dental erozyon

    NARCIS (Netherlands)

    Özen, B.; Yönel, N.; Çetiner, S.

    2015-01-01

    Dental erozyon, plak içermeyen diş yüzeyleri üzerinde içsel ve dışsal asitlerin veya şelatların etkileriyle oluşan kimyasal bir aşınmadır. İçsel ve/veya dışsal kaynaklar nedensel faktörler olarak tanımlanırken tükürük ve pelikıl gibi biyolojik faktörler, yeme ve içme alışkanlıkları ve ağız hijyeni g

  9. A Dental Education Perspective on Dental Health Policy.

    Science.gov (United States)

    Morris, Alvin L.

    1985-01-01

    Two issues related to dental health policy are examined: the contribution of dental education to the process by which dental health policy is established, and the nature of dental education's response to established policies. (MLW)

  10. Impact–abrasion wear characteristics of in-situ VC-reinforced austenitic steel matrix composite

    Energy Technology Data Exchange (ETDEWEB)

    Moghaddam, E.G., E-mail: emad_g_moghaddam@alum.sharif.edu [Department of Materials Science and Engineering, Sharif University of Technology, P.O. Box 11365-9466, Azadi Avenue, Tehran (Iran, Islamic Republic of); Karimzadeh, N. [Department of Materials Engineering, Islamic Azad University, Najafabad Branch, Isfahan (Iran, Islamic Republic of); Varahram, N.; Davami, P. [Department of Materials Science and Engineering, Sharif University of Technology, P.O. Box 11365-9466, Azadi Avenue, Tehran (Iran, Islamic Republic of)

    2013-11-15

    In this investigation, in-situ precipitation of vanadium carbides was employed to reinforce Fe–13Mn and Fe–13Mn–3W alloys by means of conventional melting and casting route. Microstructures were characterized by optical and scanning electron microscopy techniques. Mechanical properties of the materials were determined by hardness, impact toughness and tension tests. It was observed that tungsten improved the strength of the matrix and the reinforcements as well as tensile properties and work hardening rate of the VC-reinforced composite. Ball mill abrasion test was utilized to simulate impact–abrasion wear condition using two types of abrasive minerals. The results showed that the degree of benefit to be gained by the use of in-situ VC-reinforced composite materials depends strongly on crush strength of the abrasives. It was found that the studied particle-reinforced composite materials were only advantageous when the abrasives were relatively soft, providing low-stress abrasion condition.

  11. RESEARCH ON ABRASION OF DEBRIS FLOW TO HIGH-SPEED DRAINAGE STRUCTURE

    Institute of Scientific and Technical Information of China (English)

    陈洪凯; 唐红梅; 吴四飞

    2004-01-01

    As one weak topic in research of debris flow, abrasion of debris flow shortens obviously application life of control structure composed of concrete. High-speed drainage structure, one of the most effective techniques to control giant debris flow disaster, has shortened one-third application life due to abrasion by debris flow. Based on velocity calculation method founded by two-phase theory, research of abrasion mechanism of debris flow to high-speed drainage structure was made. The mechanism includes both abrasion mechanism of homogeneous sizing and shearing mechanism of particle of debris flow to high-speed drainage trough structure. Further abrasion equations of both sizing and particle were established by Newton movement theory of debris flow. And abrasion amount formula of the high-speed drainage trough structure is set up by dimensional analysis. Amount to calculating in the formula is consistent with testing data in-situ, which is valuable in design of high-speed drainage structure.

  12. Nano-sized aerosol classification, collection and analysis--method development using dental composite materials.

    Science.gov (United States)

    Bogdan, Axel; Buckett, Mary I; Japuntich, Daniel A

    2014-01-01

    This article presents a methodical approach for generating, collecting, and analyzing nano-size (1-100 nm) aerosol from abraded dental composite materials. Existing aerosol sampling instruments were combined with a custom-made sampling chamber to create and sample a fresh, steady-state aerosol size distribution before significant Brownian coagulation. Morphological, size, and compositional information was obtained by Transmission Electron Microscopy (TEM). To create samples sizes suitable for TEM analysis, aerosol concentrations in the test chamber had to be much higher than one would typically expect in a dental office, and therefore, these results do not represent patient or dental personnel exposures. Results show that nano-size aerosol was produced by the dental drill alone, with and without cooling water drip, prior to abrasion of dental composite. During abrasion, aerosol generation seemed independent of the percent filler load of the restorative material and the operator who generated the test aerosol. TEM investigation showed that "chunks" of filler and resin were generated in the nano-size range; however, free nano-size filler particles were not observed. The majority of observed particles consisted of oil droplets, ash, and graphitic structures.

  13. COMMUNITY DENTAL HEALTH SURVEY TRAINING TO DENTAL HEALTH PERSONNEL

    OpenAIRE

    Sandra Fikawati; Ita Yulita

    2015-01-01

    Dentist and dental nurse as dental health personnel in community health center are spearheads in community dental health service. The effectiveness and efficacy of community dental health service needs updated adequate dental health knowledge and skill. One effort to assure the fulfillment of those needs is by providing community dental health survey training. This training aims at improving the skill and capability of dental health personnel to conduct dental health survey. The training cons...

  14. The Effect of Microstructure on the Abrasion Resistance of Low Alloyed Steels

    OpenAIRE

    Xu, X.

    2016-01-01

    The thesis attempts to develop advanced high abrasion resistant steels with low hardness in combination with good toughness, processability and low alloying additions. For this purpose, a novel multi-pass dual-indenter (MPDI) scratch test approach has been developed to approach the real continuous abrasion process and unravel abrasion damage formation in construction steels, i.e. carrying out scratch tests using a large indenter with different pre-loads to generate a wide pre-scratch with sta...

  15. The measurement of the velocity of abrasive particles at the suction part of the cutting head

    OpenAIRE

    Foldyna, J. (Josef); M. Zeleňák; Klich, J. (Jiří); Hlaváček, P.; Sitek, L. (Libor)

    2013-01-01

    To be able to optimize the design of the abrasive cutting head using numerical simulation, it is necessary to gather as much information about processes occurring in the cutting head as possible. The development of the numerical model of processes occurring in the abrasive water jet cutting head during the process of creation and forming of abrasive water jet is currently in progress at the Institute of Geonics in Ostrava. The verification of the model requires, among others, to determine the...

  16. Technical Possibilities of Noise Reduction in Material Cutting by Abrasive Water-jet

    OpenAIRE

    Radvanská, Agáta; Ergić, Todor; IVANDIĆ, Željko; Hloch, Sergej; Valiček, Jan; Mullerova, Jana

    2009-01-01

    The technical procedure of noise reduction in material cutting by abrasive water-jet is described in this paper. The paper is aimed at the implementation of technical possibilities of noise reduction in the cutting of material by abrasive water-jet technology. Both the theoretical and experimental investigations were performed to verify and specify the new findings in the reduction of acoustic sound pressure at abrasive water-jet machining of engineering materials. By means of identification,...

  17. The measurement of the velocity of abrasive particlesat the suction part of the cutting head

    OpenAIRE

    Foldyna, J. (Josef); M. Zeleňák; Klich, J. (Jiří); Hlaváček, P.; Sitek, L. (Libor); Z. Říha

    2015-01-01

    To be able to optimize the design of the abrasive cutting head using numerical simulation, it is necessary to gather as much information about processes occurring in the cutting head as possible. The development of the numerical model of processes occurring in the abrasive water jet cutting head during the process of creation and forming of abrasive water jet is currently in progress at the Institute of Geonics in Ostrava. The verification of the model requires, among others, to determine the...

  18. EXPERIMENTAL STUDY ON VELOCITY PROFILE OF SUBMERGED ABRASIVE SUSPENSION JET FLOW

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    Abrasive jet cutting, as a more efficient machining or cutting method, has emerged in recent years in mining and machining industries, but the knowledge about velocity profile of abrasive jet flow lacks in general. In practice, the Polyacrylamide (PAM) is generally applied to jet fluid to increase the suspension of the abrasive particles. Also, the effects of PAM on jet flow are not very clear. In this paper, velocity fields of both the abrasive particles and the fluid were systematically studied with the PIV technology. The slip velocity between the abrasive particle and the surrounding fluid was subtracted out to give a further description of abrasive suspension jet. The effects of polymer PAM on both the fluid flow and the movement of the suspending abrasive particles were also measured. And it is found that the PAM is a proper type of additive to improve velocity fields for both the abrasive particles and the fluid in a jet. The results of the PIV measurement can help give a better understanding about the basic physics of abrasive suspension jet flow, and a good guidance to validate and develop reliable computational models to describe the jet.

  19. A comparison of the abrasiveness of six ceramic surfaces and gold.

    Science.gov (United States)

    Jacobi, R; Shillingburg, H T; Duncanson, M G

    1991-09-01

    A type III gold alloy and six different ceramic surfaces were secured in an abrasion machine opposing extracted teeth to determine their relative abrasiveness and resistance to wear. The rankings of restorative materials from least abrasive to most abrasive were: gold alloy, polished; cast ceramic, polished; porcelain, polished; cast ceramic, polished and shaded; porcelain, polished and glazed; cast ceramic, cerammed skin shaded; and cast ceramic, cerammed skin unshaded. The ranking of materials from most wear-resistant to least wear-resistant was: gold alloy, cast ceramic cerammed, cast ceramic cerammed and shaded, porcelain polished, porcelain glazed, cast ceramic polished and shaded, and cast ceramic polished.

  20. RESEARCH ABOUT RESULTS REPRODUTIBILITY AND ABRASIVE PARTICLES FRAGMENTATION IN BALL-CRATERING TESTS

    Directory of Open Access Journals (Sweden)

    Ronaldo Câmara Cozza

    2013-06-01

    Full Text Available The micro-abrasive wear tests by rotating ball (crater wear have played an important role in abrasive wear researches. In this type of test, the contact between a specimen and a ball on rotating motion and abrasive particles supplied between these two elements, results in a crater on the specimen, based on which the abrasive wear behaviour is analysed. The purpose of this work is to study results the reprodutibility and the silicon carbide (SiC abrasive particles fragmentation during micro-abrasive wear tests. Tests were conducted with carburized AISI 1010 steel balls and high speed steel specimens, “with” and “without” titanium nitride (TiN coatings. The abrasive slurry was prepared with black silicon carbide (average particle size of 5 µm and distilled water. Grooving abrasion is related with lower reprodutibility results. For the test conditions of this work, no abrasive particles fragmentation was observed, independently of the sliding distance, what is justified, among others factors, by the low normal force applied.

  1. Surface roughness and wear of resin cements after toothbrush abrasion

    Directory of Open Access Journals (Sweden)

    Sérgio Kiyoshi ISHIKIRIAMA

    2015-01-01

    Full Text Available Increased surface roughness and wear of resin cements may cause failure of indirect restorations. The aim of this study was to evaluate quantitatively the surface roughness change and the vertical wear of four resin cements subjected to mechanical toothbrushing abrasion. Ten rectangular specimens (15 × 5 × 4 mm were fabricated according to manufacturer instructions for each group (n = 10: Nexus 3, Kerr (NX3; RelyX ARC, 3M ESPE (ARC; RelyX U100, 3M ESPE (U100; and Variolink II, Ivoclar/Vivadent (VL2. Initial roughness (Ra, µm was obtained through 5 readings with a roughness meter. Specimens were then subjected to toothbrushing abrasion (100,000 cycles, and further evaluation was conducted for final roughness. Vertical wear (µm was quantified by 3 readings of the real profile between control and brushed surfaces. Data were subjected to analysis of variance, followed by Tukey’s test (p < 0.05. The Pearson correlation test was performed between the surface roughness change and wear (p < 0.05. The mean values of initial/final roughness (Ra, µm/wear (µm were as follows: NX3 (0.078/0.127/23.175; ARC (0.086/0.246/20.263; U100 (0.296/0.589/16.952; and VL2 (0.313/0.512/22.876. Toothbrushing abrasion increased surface roughness and wear of all resin cements tested, although no correlation was found between those variables. Vertical wear was similar among groups; however, it was considered high and may lead to gap formation in indirect restorations.

  2. Diffuse corneal abrasion after ocular exposure to laundry detergent pod.

    Science.gov (United States)

    Whitney, Rachel E; Baum, Carl R; Aronson, Paul L

    2015-02-01

    Although ocular injury from alkaline household cleaning products is well described, there is less known about the significance and extent of injury with ocular exposure to detergent pods. We report a 12-month-old with diffuse corneal abrasion caused by ocular contact with a laundry detergent pod. In addition to the known risks with aspiration with detergent pods, the potential for severe ocular injury is important for parents and clinicians to recognize. Children with ocular exposure to detergent pods should seek immediate medical care.

  3. Characteristics and mechanism of abrasive wear for thermoplastic polymers

    Institute of Scientific and Technical Information of China (English)

    Xian Jia; Xiaomei Ling

    2003-01-01

    Abrasive wear characteristics of polyethylene, polystyrene, polymethylmethacrylate, nylon 1010 and polyvinyl chloride were investigated. The volume relative wear resistance coefficients of these thermoplastic polymers are 18%-35 % (hardened and low temperature tempered steel 45 was used as a comparing material), and have a linear correlation with square roots of their cohesive energy densities. The coefficients of linear correlation is 0.949. Wear morphologies were observed by scanning electron microscope (SEM). Main wear mechanism of the thermoplastic polymers includes brittle breaking for the hard and brittle polymers & plowing and fatiguing for the soft and tough ones.

  4. Standard Test Method for Abrasive Wear Resistance of Cemented

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method covers the determination of abrasive wear resistance of cemented carbides. 1.2 The values stated in inch-pound units are to be regarded as the standard. The SI equivalents of inch-pound units are in parentheses and may be approximate. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  5. Mechanical issues in laser and abrasive water jet cutting

    Science.gov (United States)

    Singh, Jogender; Jain, Sulekh C.

    1995-01-01

    In forging and other metal-working industries, lasers and abrasive water jets are being applied to cut a variety of metal products to improve productivity and reduce costs. As described in the following, both the processes have their unique cutting capabilities and characteristics. Before selecting one, however, users must be aware of how each technique influences the end product as well as its performance (e.g., high-cycle fatigue life). For this article, we examined the mechanics of these two cutting processes by studying their effects on Ti-6Al-4Vand A286 steel.

  6. Development of the white cast iron with niobium alloy, heat treating, to wear of the abrasive resistance; Desenvolvimento de uma liga de ferro fundido branco alto cromo com niobio, tratada termicamente, para resistencia ao desgaste abrasivo

    Energy Technology Data Exchange (ETDEWEB)

    Farah, Alessandro Fraga

    1997-07-01

    This work presents the heat treatment and abrasion tests results of a white cast iron with niobium alloy. The hardening heat treatment were made 950, 1000, 1050 e 110 deg C temperatures cooled by forced air. The tempering treatment were made at 450, 500 e 550 deg C temperatures. The heat treating alloy were compared, in the abrasive tests, with commercial alloys used as hardfacing by welding process in wear pieces. The abrasion tests was realized in pin on disk test. Additional tests were carried out for microstructural characterization to identify the different phases presents in the alloys. In a general way, the alloy studies showed the best wear rate for the heat treatments that results in higher hardness. It performance was superior than that of the commercial alloys. (author)

  7. Determinación de los niveles de mercurio en el aire de consultorios y clínicas odontológicas en Cartagena Colombia / Determination of mercury levels in the air of dental offices and clinics in Cartagena, Colombia

    OpenAIRE

    Arrázola Díaz, Armida María

    2011-01-01

    El vapor de mercurio generado por la colocación y extracción de amalgamas dentales es un contaminante en los ambientes clínicos odontológicos debido a su toxicidad y energía cinética que le imprime la pieza de mano utilizada para este fin, haciendo más fácil su penetración al tracto respiratorio. El objetivo primordial de la presente investigación fue determinar los niveles de mercurio en el aire de consultorios y clínicas odontológicas de la ciudad de Cartagena, Colombia. Para tal fin se ...

  8. Dental Encounter System (DES)

    Data.gov (United States)

    Department of Veterans Affairs — Dental Encounter System (DES) is an automated health care application designed to capture critical data about the operations of VA Dental Services. Information on...

  9. Dental education in Malaysia.

    Science.gov (United States)

    Komabayashi, Takashi; Razak, Abdul Aziz Abdul; Bird, William F

    2007-12-01

    There was only one dental school in Malaysia until 1997 but five new schools have been established since 1998. This review provides information about dental education in Malaysia including; the history of dental education, the current dental school system and curriculum, and dental licensure. There are four public and two private dental schools in Malaysia. High school graduates are required to take the nationwide matriculation entrance examination or the Higher School Certificate (HSC) to apply for a dental degree programme. A five-year dental programme leads to the BDS or the DDS degree. National or state examinations are not required to practise dentistry. Currently, there are approximately 2,500 dentists, with a ratio of 1 dentist for every 10,000 people.

  10. 75 FR 33169 - Dental Devices: Classification of Dental Amalgam, Reclassification of Dental Mercury, Designation...

    Science.gov (United States)

    2010-06-11

    ...-AG21 Dental Devices: Classification of Dental Amalgam, Reclassification of Dental Mercury, Designation of Special Controls for Dental Amalgam, Mercury, and Amalgam Alloy; Technical Amendment AGENCY: Food... classified dental amalgam as a class II device, reclassified dental mercury from class I to class II,...

  11. Shrinkage, abrasion, erosion and sorption of clay plasters

    Directory of Open Access Journals (Sweden)

    Minke, G.

    2011-09-01

    Full Text Available At the Buildung Research Institute (FEB, Faculty of Architecture, University of Kassel, Germany, in the last years several hundred tests were made to study the characteristics of different loam mortars in respect of their linear shrinkage, absorption of humidity and their resistance against abrasion and erosion. In order to get data about abrasion and erosion new test methods and special apparatusses were developed. The mortars tested, chosen from the market, showed extremely varying test results.

    En el Laboratorio de Construcciones Experimentales (FEB de la Facultad de Arquitectura, Universidad de Kassel, Alemania, fueron testeados cientos de diferentes pruebas de revoque de barro para estudiar su contracción durante el secado, su absorción de humedad y su resistencia contra abrasión, erosión y absorción. Para recibir datos sobre abrasión y erosión, nuevas aparatos y metodos fueron desarrollados. Los resultados de los revoques comprados en el mercado muestran gran diferencias en los valores.

  12. Study on mineral processing technology for abrasive minerals

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Seong Woong; Yang, Jung Il; Hwang, Seon Kook; Choi, Yeon Ho; Cho, Ken Joon; Shin, Hee Young [Korea Inst. of Geology Mining and Materials, Taejon (Korea, Republic of)

    1995-12-01

    Buyeo Materials in Buyeogun, Choongnam province is a company producing feldspar concentrate, but does not yet utilize the garnet as abrasive material and other useful heavy minerals wasted out from the process of feldspar ore. The purpose of this study is to develop technology and process for the recovery of garnet concentrate. As results, the garnet is defined as ferro manganese garnet. The optimum process for recovery of garnet concentrate is to primarily concentrate heavy minerals from tailings of feldspar processing. And secondly the heavy minerals concentrated is dried and separated garnet concentrate from other heavy minerals. At this time, the garnet concentrate is yield by 0.176%wt from 0.31%wt of heavy minerals in head ore. The garnet concentrate contains 33.35% SiO{sub 2}, 12.20% Al{sub 2}O{sub 3}, 28.47% Fe{sub 2}O{sub 3}, 11.96% MnO. As for utilization of abrasive materials, a fundamental data was established on technology of grinding and classification. (author). 13 refs., 47 figs., 24 tabs.

  13. Abrasive waterjet machining of fiber reinforced composites: A review

    Science.gov (United States)

    Kalla, D. K.; Dhanasekaran, P. S.; Zhang, B.; Asmatulu, R.

    2012-04-01

    Machining of fiber reinforced polymer (FRP) composites is a major secondary manufacturing activity in the aircraft and automotive industries. Traditional machining of these composites is difficult due to the high abrasiveness nature of their reinforcing constituents. Almost all the traditional machining processes involve in the dissipation of heat into the workpiece which can be resulted in damage to workpiece and rapid wear of the cutting tool. This serious issue has been overcome by water jetting technologies. Abrasive waterjet machining (AWJM) is a nontraditional method and one of the best options for machining FRPs. This paper presents a review of the ongoing research and development in AWJM of FRPs, with a critical review of the physics of the machining process, surface characterization, modeling and the newer application to the basic research. Variable cutting parameters, limitations and safety aspects of AWJM and the noise related issues due to high flow rate of water jet will be addressed. Further challenges and scope of the future development in AWJM are also presented in detail.

  14. Abrasive-assisted Nickel Electroforming Process with Moving Cathode

    Science.gov (United States)

    REN, Jianhua; ZHU, Zengwei; XIA, Chunqiu; QU, Ningsong; ZHU, Di

    2017-03-01

    In traditional electroforming process for revolving parts with complex profiles, the drawbacks on surface of deposits, such as pinholes and nodules, will lead to varying physical and mechanical properties on different parts of electroformed components. To solve the problem, compositely moving cathode is employed in abrasive-assisted electroforming of revolving parts with complicated profiles. The cathode translates and rotates simultaneously to achieve uniform friction effect on deposits without drawbacks. The influences of current density and translation speed on the microstructure and properties of the electroformed nickel layers are investigated. It is found that abrasive-assisted electroforming with compound cathode motion can effectively remove the pinholes and nodules, positively affect the crystal nucleation, and refine the grains of layer. The increase of current density will lead to coarse microstructure and lower micro hardness, from 325 HV down to 189 HV. While, faster translational linear speed produces better surface quality and higher micro hardness, from 236 HV up to 283 HV. The weld-ability of the electroformed layers are also studied through the metallurgical analysis of welded joints between nickel layer and 304 stainless steel. The electrodeposited nickel layer shows fine performance in welding. The novel compound motion of cathode promotes the mechanical properties and refines the microstructure of deposited layer.

  15. Abrasive Wear Map of Polymer Tapes in Sand Dust Environment

    Institute of Scientific and Technical Information of China (English)

    WU Tong-hai; DIAO Dong-feng

    2006-01-01

    To make clear the wear conditions of ATM (Automatic Teller Machine) tribosystem when servicing in Chinese sand dust environment, abrasive wear of two kinds of polymer tapes specified for ATM, PI (Polyimide) and PEN (Polyethylene-2, 6-naphthalenedicarboxylate), was investigated in simulated sand dust environment with ATM tape-scraper tribosystem under various conditions of loads and sliding distances. The surface profiles of worn tape were measured with a surface profiler in order to calculating the wear cross-section areas and the wear volumes. The specific wear rates of polymer tapes were calculated under load conditions of 0.6, 1 and 1.5 N, and wear mechanisms were investigated with optical topography photos. As main results, the specific wear rates show stage variations in the wear process and the wear resistance of polymer tape shows good relationship with the mechanical deformation factors. In consideration of the service life, four wear models are generalized according to the magnitude of specific wear rates,which include no wear, mild wear, normal wear and severe wear model and the corresponding wear mechanisms for the four wear models are discussed with typical worn topographies. Based on the wear models and corresponding wear mechanisms, the abrasive wear maps of two polymer tapes servicing in sand dust environments are concluded for its industrial applications.

  16. Polyurethanes from the crystalline prepolymers resistant to abrasive wear

    Directory of Open Access Journals (Sweden)

    Domańska Agata

    2014-12-01

    Full Text Available The research aimed at the selection of polyurethanes synthesized from poly(tetramethylene ether glycol (PTMEG, as well as from two different isocyanates 4,4′-methylenebis(cyclohexylisocyanate (HMDI and 4.4′-methylenebis(phenyl isocyanate (MDI in order to obtain polyurethane with increased resistance to abrasive wear and degradation for bio-medical application. Polyurethanes were fabricated from crystalline prepolymers extended by water. The paper presents preliminary results on polyurethane surface wettability, friction coefficient for different couples of the co-working materials such as polyurethane-polyurethane, polyurethane-titanium alloy, polyurethane-alumina, in comparison to commonly used polyethylene-titanium alloy. Shear strength of polyurethane-alumina joint, as well as viscosity of prepolymers were also measured. The values of friction coefficient were compared to literature data on commercially available polyurethane with the trade name Pellethane. Polyurethanes obtained are characterized by low abrasive wear and low friction coefficient in couple with the titanium alloy, what makes them attractive as possible components of ceramic-polymer endoprosthesis joints.

  17. [Dental records and responsibility

    NARCIS (Netherlands)

    Brands, W.G.

    2006-01-01

    Dental records are more than a small part of the bookkeeping. In most dental practises, keeping records is the task of a dental assistant. In civil court, the dentist is in most countries liable for the mistakes of his employees. In disciplinary court however there may be doubt whether the dentist i

  18. Stress Among Dental Students

    NARCIS (Netherlands)

    A.M. Alzahem (Abdullah)

    2015-01-01

    markdownabstractAbstract Dental students are facing many stressors in dental education, causing many negative outcomes. The most common are the exams and the clinical requirements. We suggest exposing the dental students to patient care as early as possible in their curriculum. This can help to bal

  19. Cutting Tools, Files and Abrasives. Pre-Apprenticeship Phase 1 Training.

    Science.gov (United States)

    Lane Community Coll., Eugene, OR.

    This self-paced student training module on cutting tools, files, and abrasives is one of a number of modules developed for Pre-apprenticeship Phase 1 Training. Purpose of the module is to enable students to identify and explain the proper use and care of various knives, saws, snips, chisels, and abrasives. The module may contain some or all of the…

  20. 16 CFR Figure 8 to Part 1512 - Reflectorized Bicycle Wheel Rim Abrasion Test Device

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Reflectorized Bicycle Wheel Rim Abrasion... HAZARDOUS SUBSTANCES ACT REGULATIONS REQUIREMENTS FOR BICYCLES Pt. 1512, Fig. 8 Figure 8 to Part 1512—Reflectorized Bicycle Wheel Rim Abrasion Test Device EC03OC91.074...

  1. Deformation of a dental ceramic following adhesive cementation.

    LENUS (Irish Health Repository)

    2010-01-01

    Stress-induced changes imparted in a \\'dentin-bonded-crown\\' material during sintering, annealing, pre-cementation surface modification, and resin coating have been visualized by profilometry. The hypothesis tested was that operative techniques modify the stressing pattern throughout the material thickness. We polished the upper surfaces of 10 ceramic discs to remove surface imperfections before using a contact profilometer (40-nm resolution) to measure the \\'flatness\\'. Discs were re-profiled after annealing and after alumina particle air-abrasion and resin-coating of the \\'fit\\' surface. Polished surfaces were convex, with a mean deflection of 8.4 + or - 1.5 microm. Mean deflection was significantly reduced (P = 0.029) following alumina particle air-abrasion and increased (P < 0.001) on resin-coating. Polishing induced a tensile stress state, resulting in surface convexity. Alumina particle air-abrasion reduced the relative tensile stress state of the contralateral polished surface. Resin-polymerization generated compression within the resin-ceramic \\'hybrid layer\\' and tension in the polished surface and is likely to contribute to the strengthening of ceramics by resin-based cements.

  2. A review of engineering control technology for exposures generated during abrasive blasting operations.

    Science.gov (United States)

    Flynn, Michael R; Susi, Pam

    2004-10-01

    This literature review presents information on measures for controlling worker exposure to toxic airborne contaminants generated during abrasive blasting operations occurring primarily in the construction industry. The exposures of concern include respirable crystalline silica, lead, chromates, and other toxic metals. Unfortunately, silica sand continues to be widely used in the United States as an abrasive blasting medium, resulting in high exposures to operators and surrounding personnel. Recently, several alternative abrasives have emerged as potential substitutes for sand, but they seem to be underused Some of these abrasives may pose additional metal exposure hazards. In addition, several new and improved technologies offer promise for reducing or eliminating exposures; these include wet abrasive blasting, high-pressure water jetting, vacuum blasting, and automated/robotic systems. More research, particularly field studies, is needed to evaluate control interventions in this important and hazardous operation.

  3. Two-Body Abrasive Wear of the Surfaces of Pangolin Scales

    Institute of Scientific and Technical Information of China (English)

    Jin Tong; Tie-biao Lü; Yun-hai Ma; Heng-kun Wang; Lu-quan Ren; R. D. Arnell

    2007-01-01

    The Pangolin, a soil-burrowing animal, is covered with scales. These scales are often abraded by soil and rock and their surface is corrugated. The abrasive wear of the surface of the scales was examined. The scales were taken from a pangolin that had died of natural causes. The tests were run on a rotary disc abrasive wear tester. The abrasive material was quartz sand (96.5 wt.%) and bentonite (3.5 wt.%). The morphology of the abraded surfaces and the abrasion were examined by stereoscopic microscopy and scanning electron microscopy. The concepts are proposed of "Guiding-Effect" and "Rolling-Effect" on the textured surfaces under free abrasive wear conditions and the critical dimensions of the "Rolling-Effect" are discussed.

  4. Is water in dental units microbiologically safe?

    Directory of Open Access Journals (Sweden)

    Michał Michałkiewicz

    2015-12-01

    Full Text Available Background: Water supplied to the dental units must be of sufficient quality. The article presents the results of the microbiological analysis of cold municipal water which flows into a patient’s disposable mouthwash cup, and demineralized water which flows through a waterline into the tool panel of a dental unit from the tank placed in the water group. Material and Methods: In order to assess the degree of purity (impurities of water used in dental units, 2 series of microbiological tests were carried out in 6 dental surgeries from April to June, 2013. The water samples for microbiological testing were collected into sterile microbiological bottles in accordance with the current methodology. The water for the tests was collected from a sterile cup-filling tap (municipal water and from an air/water syringe (demineralized water. The bacteria were cultured according to the Polish Standards – PN-EN ISO 6222, PN-EN ISO 9308-1, and PN-EN ISO 16266. Results: In the tested samples of water numerous psychrophilic bacteria (max 29 100 CFU/ml and mesophilic bacteria (max 24 700 CFU/ml, including single coliforms, were found. Conclusions: The results show that water delivered to a dental unit should be periodically tested bacteriologically and in terms of physical and chemical properties. Water systems of dental units should also be periodically disinfected to eliminate bacteria and biofilm. Med Pr 2015;66(6:763–770

  5. [Dental technician's pneumoconiosis; a case report].

    Science.gov (United States)

    Karaman Eyüboğlu, Canan; Itil, Oya; Gülşen, Aşkin; Kargi, Aydanur; Cimrin, Arif

    2008-01-01

    Since 1939, it has been known that, silicosis and extrinsic allergic alveolitis can be seen among dental technicians. The interstitial disease caused by the exposure to complex substances used by dental technicians is classified as a special group called dental technician's pneumoconiosis. A 36-year-old man, who has no smoking history, presented with severe dyspnea. He had worked in different dental laboratories for 22 years, but he did not have respiratory symptoms until five years ago. After that date, he had hospitalized and had been examined for respiratory pathologies for many times. He had came to our clinic, because of the progression of his dyspnea. Diffuse pulmonary parenchymal infiltrates which can be related with pneumoconiosis and chronic type 1 respiratory deficiency had been diagnosed as the result of the examinations. While he has no history of smoking or any other risk factors or diseases in his medical history, the case was accepted as dental technician's pneumoconiosis. The factors related with the pathogenesis of dental technician's pneumoconiosis are; the complex compound of the substances (metal dusts, silica, plaster, wax and resins, chemical liquids, methyl methacrylate) used in this sector and their effects on the lung parenchyma. Extrinsic allergic alveolitis related with methyl methacrylate has been reported. The most important factor to acquire an occupational lung disease is a complex occupational exposure. The insufficient workplace airing and the lack of preventive measures added on this exposure, the risks become much more greater.

  6. Investigation of the abrasive lapping of oxide ceramics

    Directory of Open Access Journals (Sweden)

    Almaz Mullayanovich Khanov

    2016-03-01

    Full Text Available In this paper the methods of ceramic materials treatments are summarized. For the treatment of a technical ceramics the grinding and finishing processes including the description of the treatment steps are reported. In the first step, up to 80% of the material is polished away and the grinding is carried out at increased velocities using a tool with larger grains. In the second step of grinding, the amount of the removed material is decreased and this step is carried out using the abrasive tool with smaller grains. The third step referred as finishing is done by diamond abrasive micro-powders and a paste with a certain grain size. Often, after this step the polishing is performed in order to achieve the precision class of 1-3 and low surface roughness. The abrasive finishing of the materials based on the oxide ceramics VSH-75 is investigated. It is found that the performance ability of the diamond micro-powder is higher by a factor of 15-30 compared to the electrocorundum and green silicon carbide micro-powders. By increasing the graininess, the amount of removed material and the roughness of a treated surface are increased. In order to achieve the Rz=0.8 µm it is recommended to use a synthetic diamond micro-powder ASM20. Additionally, the influence of the contact pressure of the part onto the lap in the range from 25 to 150 kPa is investigated. With the increase of the contact pressure from 25 to 50 kPa, the total removal is significantly increasing whereas the relative diamond micro-powder consumption and surface roughness are essentially decreasing. Further increase of the contact pressure up to 150 kPa has smaller effect on the process parameters, while the cracks appear at the tool surface deteriorating the external view of the tool. The optimal contact pressure during finishing of the ceramic using the cast iron lap SCH-28 is about 50-100 kPa

  7. A new method to test rock abrasiveness based on physico-mechanical and structural properties of rocks

    Institute of Scientific and Technical Information of China (English)

    V.N. Oparin; A.S. Tanaino

    2015-01-01

    abstract A new method to test rock abrasiveness is proposed based upon the dependence of rock abrasiveness on their structural and physico-mechanical properties. The article describes the procedure of presentation of properties that govern rock abrasiveness on a canonical scale by dimensionless components, and the integrated estimation of the properties by a generalized index. The obtained results are compared with the known classifications of rock abrasiveness.

  8. Surface quality of marble machined by abrasive water jet

    Directory of Open Access Journals (Sweden)

    Ramy Abdullah

    2016-12-01

    Full Text Available This paper presents a study conducted to examine the effect of cutting parameters, namely standoff distance, nozzle traverse speed (TS, abrasive flow rate (AFR, and material type on cutting performance for two types of marble workpieces, Carrara white and Indian green. Statistical analysis was undertaken to assess the influence of the cutting parameters on the process performances in terms of surface roughness, surface waviness, and Kerf taper ratio. The results showed that the TS and material type were the most significant factors that affected surface roughness and Kerf taper ratio. Also, although AFR was found to have significant effect on surface waviness, it had no noticeable influence on surface roughness nor Kerf taper ratio.

  9. Standard test method for jaw crusher gouging abrasion test

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1997-01-01

    1.1 This test method covers a laboratory procedure to determine the relative gouging abrasion resistance of materials. Materials homogeneous in structure and properties are the most appropriate test materials; however, surface-treated and composite materials can also be tested. The test involves a small laboratory jaw crusher that crushes presized hard rock materials, such as a hard morainal gravel, or some other crushable substance. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. (See 8.1 on Safety Precautions.)

  10. Graphite Intended for Green Engineering Developed by Noncontaminant Reverse Abrasion

    Directory of Open Access Journals (Sweden)

    Roberto Baca Arroyo

    2016-01-01

    Full Text Available Graphite intended for green engineering was synthesized by noncontaminant reverse abrasion, which consists of graphite layers assembled with thickness controlled on SiC sandpaper as insulating substrate. Phase formation of the graphite layers was validated by X-ray diffraction studies and its finished profile by Atomic Force Microscopy (AFM. Transport parameters of only three layers were evaluated from current-voltage curves. Mathematical functions such as derivative and modulation of a signal have been built by graphite circuits using different performance principles, compared to those used with silicon devices. The trends related to electronic engineering should be achieved with design of the graphite-based devices to facilitate their mass production in the near future.

  11. PROFILE ANALYSIS OF STANDARD TEETH WEAR IN PEOPLE SUFFERING FROM BRUXISM AND ITS RELATIONSHIP WITH DENTAL EROSION: A LONGITUDINAL ANALYSIS

    OpenAIRE

    Bonato, Letícia Ladeira; Universidade Federal Fluminense; Bastos, Flávia de Souza; Universidade Federal de Juiz de Fora; Meireles, Agnes Batista; Universidade Federal de Minas Gerais; de Ávila, Renato Françoso; Instituto Federal de Educação, Ciência e Tecnologia (Campus Juiz de Fora); GUIMARÃES,Josemar Parreira

    2015-01-01

    Although teeth wear is a physiological process, bruxism or teeth grinding is indicated as the sole etiological factor involved, without taking into consideration other wear processes, such as erosion and abrasion. Current descriptive and longitudinal analysis evaluates the surface roughness in teeth as dental wear standard in females diagnosed with acid erosion or attrition. Sample comprised 20 females, aged between 20 and 50 years old, divided into Group A (n=9) characterized by teeth grindi...

  12. Dental caries vaccine

    Directory of Open Access Journals (Sweden)

    Shivakumar K

    2009-01-01

    Full Text Available Dental caries is one of the most common diseases in humans. In modern times, it has reached epidemic proportions. Dental caries is an infectious microbiologic disease of the teeth that results in localized dissolution and destruction of the calcified tissue. Dental caries is a mulitifactorial disease, which is caused by host, agent, and environmental factors. The time factor is important for the development and progression of dental caries. A wide group of microorganisms are identified from carious lesions of which S. mutans , Lactobacillus acidophilus , and Actinomyces viscosus are the main pathogenic species involved in the initiation and development of dental caries. In India, surveys done on school children showed caries prevalence of approximately 58%. Surveys among the U.S. population showed an incidence of 45.3% in children and 93.8% in adults with either past or present coronal caries. Huge amounts of money and time are spent in treating dental caries. Hence, the prevention and control of dental caries is the main aim of public health, eventually the ultimate objective of public health is the elimination of the disease itself. Recently, dental caries vaccines have been developed for the prevention of dental caries. These dental caries vaccines are still in the early stages.

  13. What is dental ecology?

    Science.gov (United States)

    Cuozzo, Frank P; Sauther, Michelle L

    2012-06-01

    Teeth have long been used as indicators of primate ecology. Early work focused on the links between dental morphology, diet, and behavior, with more recent years emphasizing dental wear, microstructure, development, and biogeochemistry, to understand primate ecology. Our study of Lemur catta at the Beza Mahafaly Special Reserve, Madagascar, has revealed an unusual pattern of severe tooth wear and frequent tooth loss, primarily the result of consuming a fallback food for which these primates are not dentally adapted. Interpreting these data was only possible by combining our areas of expertise (dental anatomy [FC] and primate ecology [MS]). By integrating theoretical, methodological, and applied aspects of both areas of research, we adopted the term "dental ecology"-defined as the broad study of how teeth respond to the environment. Specifically, we view dental ecology as an interpretive framework using teeth as a vehicle for understanding an organism's ecology, which builds upon earlier work, but creates a new synthesis of anatomy and ecology that is only possible with detailed knowledge of living primates. This framework includes (1) identifying patterns of dental pathology and tooth use-wear, within the context of feeding ecology, behavior, habitat variation, and anthropogenic change, (2) assessing ways in which dental development and biogeochemical signals can reflect habitat, environmental change and/or stress, and (3) how dental microstructure and macro-morphology are adapted to, and reflect feeding ecology. Here we define dental ecology, provide a short summary of the development of this perspective, and place our new work into this context.

  14. Dental hygiene in Slovakia.

    Science.gov (United States)

    Luciak-Donsberger, C; Krizanová, M

    2004-08-01

    This article reports on the development of the dental hygiene profession in Slovakia from a global perspective. The aim is to inform about current developments and to examine, how access to qualified dental hygiene care might be improved and how professional challenges might be met. For an international study on dental hygiene, secondary source data were obtained from members of the House of Delegates of the International Federation of Dental Hygienists (IFDH) or by fax and e-mail from experts involved in the national professional and educational organization of dental hygiene in non-IFDH member countries, such as Slovakia. Responses were followed-up by interviews, e-mail correspondence, visits to international universities, and a review of supporting studies and reference literature. Results show that the introduction of dental hygiene in Slovakia in 1992 was inspired by the delivery of preventive care in Switzerland. Initiating local dentists and dental hygienists strive to attain a high educational level, equitable to that of countries in which dental hygiene has an established tradition of high quality care. Low access to qualified dental hygiene care may be a result of insufficient funding for preventive services, social and cultural lack of awareness of the benefits of preventive care, and of limitations inherent in the legal constraints preventing unsupervised dental hygiene practice. These may be a result of gender politics affecting a female-dominated profession and of a perception that dental hygiene is auxiliary to dental care. International comparison show that of all Eastern European countries, the dental hygiene profession appears most advanced in Slovakia. This is expressed in high evidence-based academic goals, in extensive work with international consultants from the Netherlands and Switzerland, in annual congresses of high professional quality, and in the establishment of a profession, which has not been introduced in all Western EU countries.

  15. Mercury exposure in the work place and human health: dental amalgam use in dentistry at dental teaching institutions and private dental clinics in selected cities of Pakistan.

    Science.gov (United States)

    Khwaja, Mahmood A; Nawaz, Sadaf; Ali, Saeed Waqar

    2016-03-01

    During the past two decades, mercury has come under increasing scrutiny with regard to its safety both in the general population and in occupationally exposed groups. It's a growing issue of global concern because of its adverse environmental and health impacts. Very few investigations on mercury amalgam use in the dentistry sector have been carried out in South Asia and there is little data reported on mercury contamination of indoor/outdoor air at dental sites. According to an earlier SDPI study, reported in 2013, alarmingly high mercury levels were observed in air (indoor as well as outdoor) at 11 of the 34 visited dental sites (17 dental teaching institutions, 7 general hospitals & 10 dental clinics) in five main cities of Pakistan. 88% of the sites indicated indoor mercury levels in air above the USA EPA reference level of 300 ng/m3. According to our study, carried out at 38 dental teaching institutions in 12 main cities (in Khyber Pakhtunkhwa, Punjab and Sindh provinces) of Pakistan, respondents were of the opinion that the currently offered BDS curriculum does not effectively guide outgoing dental professionals and does not provide them adequate knowledge and training about mercury/mercury amalgam and other mercury related human health and mercury waste issues. 90% of respondents supported the review and revision of the present dental curriculum offered at dental teaching institutions in the country, at the earliest. A study has also been conducted to assess the status of mercury amalgam use in private dental clinics in Gilgit, Hunza, Peshawar, Rawalpindi and Islamabad. More than 90 private dental clinics were visited and dental professionals/private clinics in-charge were interviewed during June-July, 2015. The focus areas of the study were Hg amalgam toxicity, its waste management practices and safety measures practiced among the dental practitioners. In the light of the findings described and discussed in this brief report, to safeguard public health and

  16. Development of Abrasive Selection Model/Chart for Palm Frond Broom Peeling Machine Design

    Directory of Open Access Journals (Sweden)

    Nwankwojike

    2014-12-01

    Full Text Available A model for predicting the friction required by a palm frond broom peeling machine for effective peeling of palm leaf to broom bristle and a chart for selecting the best abrasive material for this machine’s peeling operation were developed in this study using mechanistic modeling method. The model quantified the relationship between the coefficient of friction and other operational parameters of this machine while the abrasives selection chart constitutes a plot of this measured friction parameter against the abrasive materials used in palm frond broom peeling machine fabrication. The values of the coefficient of friction of palm leaf on different abrasive materials used in this plot were determined from experimental study of the effect of moisture content level of naturally withered palm leaves (uninfluenced by external forces on their coefficient of friction with the abrasives. Results revealed the average moisture content of palm leaf this machine can peel effectively as 6.96% and also that the roughest among the abrasives that approximate the coefficient of friction for a specific design of this peeling machine gives maximum peeling efficiency. Thus, the roughest among the abrasive materials that approximate the coefficient of friction for a specific design of this machine should be selected and used for its fabrication and operation.

  17. An Investigation of Abrasive Wear Behaviour of Al 2014-SiC Composites

    Science.gov (United States)

    Çalin, Recep; Cilasun, Niyazi Selçuk

    2015-04-01

    In this study, the effects of SiC reinforcement volume fractions on hardness, porosity and abrasive wear behaviour were examined in Al 2014-SiC (composites (MMCs) of 3%, 6% and 12% reinforcement-volume (R-V) ratios produced by melt-stirring. Abrasive wear tests were carried out by 320 mesh Al2O3 abrasive paper and a pin-on-disc wear test apparatus, under 10N, 20N and 30N load, and at 0.2 ms-1 sliding speed. The same specimens were tested by 150, 240 and 320 mesh abrasive paper at 0.2 ms-1 sliding speed, under 10N, 20N and 30N load. After the tests, the microstructures of the worn surfaces were examined with scanning electron microscope (SEM) studies and EDS analyses. Besides, the amount of hardness and porosity of the specimens were identified. It was recorded that the amounts of hardness and porosity increases as the SiC reinforcement in the composite increases. The highest amount of abrasive wear was recorded in the specimens with 3% reinforcements. It was identified that the amount of abrasive wear decreases while the SiC reinforcement in the composite structure increases by volume, and that the amount of porosity and reinforcement volume (R-V) ratio are important parameters in abrasive wear.

  18. An in vitro study of dental enamel wear by restorative materials using radiometric method; Estudo in vitro do desgaste do esmalte dental pelos materiais restauradores utilizando metodo radiometrico

    Energy Technology Data Exchange (ETDEWEB)

    Adachi, Lena Katekawa

    2000-07-01

    There is an increasing demand and interest to study the dental materials wear as well as about the abrasion effect on antagonistic teeth. Due to the fact that the existent restorative materials have no specifications about their abrasiveness, it is necessary the establishment of degrees of comparison among them to support clinical application. In this work, the radiometric method was applied to study the enamel wear caused by another enamel and by restorative materials (Ceramco II, Noritake and Finesse porcelains, Artglass and Targis). The dental enamel made radioactive by irradiation at the IEA-R1m nuclear research reactor under a thermal neutron flux was submitted to wear in a machine which allows sliding motion of an antagonistic surface in contact with this radioactive enamel. The enamel wear was evaluated by measuring beta activity of {sup 32}P transferred to water from this irradiated tooth. Results obtained indicated that dental porcelains cause pronounced enamel wear when compared with that provoked by another enamel or by resin materials. Resin materials caused less enamel wear than another enamel. Vickers microhardness data obtained for antagonistic materials showed a correlation with the wear caused to the enamel. This study allowed to conclude that the radiometric method proposed can be used satisfactorily in the evaluation of enamel wear by restorative materials. This method presents advantages due to quick responses and ease of analyses There is (author)

  19. Influence of Impact Energy on Impact Corrosion-abrasion of High Manganese Steel

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    The impact corrosion-abrasion properties and mechanism of high manganese steel were investigated under different impact energies. The result shows that the wearability of the steel decreases with the increase of the impact energy. The dominant failure mechanism at a lower impact energy is the rupture of extrusion edge along root and a slight shallow-layer spalling. It transforms to shallow-layer fatigue flaking along with serious corrosion-abrasion when the impact energy is increased, and finally changes to bulk flaking of hardened layer caused by deep work-hardening and heavy corrosion-abrasion.

  20. Abrasion properties of homogenous and blended fill materials during pressure hydraulic transport

    Energy Technology Data Exchange (ETDEWEB)

    Turchaninov, S.P.

    1978-03-01

    A description is given of tests conducted to determine the abrasive properties of small and large-grain free-flowing fill materials during hydraulic transport of the materials under pressure. Data are given on the size, density, abrasiveness of various sized varieties of rock, sand, and blends comprising homogenous materials, simple and complex mixtures, and on the physical characteristics of various fill materials in relation to the trafficability and parameters of pipelines. Technical specifications are given for fill steel pipes. The study indicates that the durability of hydraulic fill pipelines largely depends on the abrasiveness of the fill materials. 3 references, 2 figures, 2 tables.

  1. An Experimental investigation of sea sand as an Abrasive material in vibrating chamber by using Tungsten Carbide Nozzle in Abrasive Jet machining Process.

    Directory of Open Access Journals (Sweden)

    N. S. Pawar

    2013-10-01

    Full Text Available A large number of investigation carried out in Abrasive jet machining and water jet machining process with different parameter but no detailed work have been found or carried out by using sea sand as an abrasive in AJM process by using different types of nozzles and variable parameters. The present work gives performance of sand having grain structure of 100-150 micron in the tungsten carbide nozzle. Theexperimentation in this study give characteristic of sea sand as abrasive material. The parameter like pressure, standoff distance of nozzle from work piece keeping constant and variable. It give the result of material removal rate , powder flow rate, similar to actually abrasive used like Aluminum oxide, silicon oxide etc. The R square value o.97 to 0.996 degree of polynomial equation. It is also notice that width of cut slightly increase with increase of feed rate .The taper cut slot was found to be a higher at greater stand of distance and work feed rate .Tungsten carbide is very hard. It maintain high cutting ability as abrasive strike on work piece

  2. Plaque growth-inhibiting effects of an abrasive fluoride-chlorhexidine toothpaste and a fluoride toothpaste containing oxidative enzymes.

    Science.gov (United States)

    Etemadzadeh, H; Ainamo, J; Murtomaa, H

    1985-08-01

    The aim of this 4 times cross-over double-blind clinical trial was to test the plaque-inhibiting effect of 2 fluoride-containing toothpastes. One toothpaste contained 0.8% chlorhexidine together with amine fluoride (0.1% F degrees) and a suitable abrasive agent. The other contained 1.7 U/g glucose oxidase and 8.0 U/g amyloglucosidase, added to an amine fluoride (0.1% F degrees) toothpaste. 1% Hibitane dental gel was used as a positive and a conventional fluoride toothpaste (Vademecum MFP Fluor) as a negative control. 9 dental students, in a randomized sequence, applied the 4 dentifrices twice daily from Monday afternoon to Friday morning with cap splints, designed to cover the teeth and about 2 mm of gingiva. No other oral hygiene measures were allowed during the 4 test periods. On Fridays, the teeth were cleaned professionally and good oral hygiene was maintained during the week-ends. At the beginning and at the end of each test period, per student plaque thickness was recorded using the plaque index, the visible plaque index, and plaque fresh weight as parameters, and the area of plaque as related to the area of the tooth surface was recorded planimetrically and according to the PLQ index. The best plaque growth-inhibiting effect was recorded for the positive control (CHX) with the test chlorhexidine toothpaste (TX) as next best. The enzyme-containing toothpaste (TE) did not differ significantly from the negative control (C). All the significant differences in anti-plaque effect between the 4 toothpastes were obtained by recordings of plaque thickness and none on the basis of area of plaque.

  3. Study on planarization machining of sapphire wafer with soft-hard mixed abrasive through mechanical chemical polishing

    Science.gov (United States)

    Xu, Yongchao; Lu, Jing; Xu, Xipeng

    2016-12-01

    This study investigated the material removal mechanism of sapphire wafer with soft-hard mixed abrasives through mechanical chemical polishing (MCP). The polishing film, which contains diamond as hard abrasives and high reactivity silica as soft abrasives, is prepared through sol-gel technology. Silica abrasives with regular spherical shape and high reactivity are prepared through hydrolysis-precipitation. Diamond grits with three different particle sizes are used as abrasives. Results show that the rate of material removal of mixed abrasives during MCP is more than 52.6% of that of single hard abrasives and the decrease in surface roughness is more than 21.6% of that of single hard abrasives. These results demonstrate that the ideal planarization of sapphire wafer with high removal rate and good surface quality can be achieved when the effect of mechanical removal of hard abrasives and the chemical corrosion effect of soft abrasives are in dynamic equilibrium. A model that describes the material removal mechanism of sapphire with mixed abrasives during MCP is proposed. The results of thermodynamic calculation and polishing residue analysis are used to demonstrate the rationality of the model.

  4. Effects of dental porcelain containing silver nanoparticles on static fatigue.

    Science.gov (United States)

    Fujieda, Tokushi; Uno, Mitsunori; Ishigami, Hajime; Kurachi, Masakazu; Kamemizu, Hideo; Wakamatsu, Nobukazu; Doi, Yutaka

    2013-01-01

    The purpose of this study was to clarify the effect of silver nanoparticles on the behavior of subcritical crack growth (SCG) in dental porcelains. Prior to occurrence of fast fracture in dental porcelains, SCG occurs and leads to strength degradation over time. SCG in dental porcelains can be characterized by the stress corrosion susceptibility coefficient, n. A higher n value means a higher resistance to SCG. In this study, porcelain disks were prepared by mixing a commercial dental porcelain powder with different concentrations of silver nanoparticles, and then air-dried and fired according to manufacturer's instructions. Stress corrosion susceptibility coefficients of powder compacts were determined using a post-indentation method. A Vickers indenter was applied to the porcelain surface, and lengths of median cracks were measured at fixed time intervals over a 24-h period to calculate n. Addition of silver nanoparticles significantly increased the stress corrosion susceptibility coefficient of dental porcelain.

  5. Dental Implant Systems

    Directory of Open Access Journals (Sweden)

    Yoshiki Oshida

    2010-04-01

    Full Text Available Among various dental materials and their successful applications, a dental implant is a good example of the integrated system of science and technology involved in multiple disciplines including surface chemistry and physics, biomechanics, from macro-scale to nano-scale manufacturing technologies and surface engineering. As many other dental materials and devices, there are crucial requirements taken upon on dental implants systems, since surface of dental implants is directly in contact with vital hard/soft tissue and is subjected to chemical as well as mechanical bio-environments. Such requirements should, at least, include biological compatibility, mechanical compatibility, and morphological compatibility to surrounding vital tissues. In this review, based on carefully selected about 500 published articles, these requirements plus MRI compatibility are firstly reviewed, followed by surface texturing methods in details. Normally dental implants are placed to lost tooth/teeth location(s in adult patients whose skeleton and bony growth have already completed. However, there are some controversial issues for placing dental implants in growing patients. This point has been, in most of dental articles, overlooked. This review, therefore, throws a deliberate sight on this point. Concluding this review, we are proposing a novel implant system that integrates materials science and up-dated surface technology to improve dental implant systems exhibiting bio- and mechano-functionalities.

  6. Dental erosion, summary.

    Science.gov (United States)

    ten Cate, J M; Imfeld, T

    1996-04-01

    Although reports on dental erosion have always appeared in the dental literature, there is currently a growing interest among researchers and clinicians. Potential risk factors for dental erosion are changed lifestyle and eating patterns, with increased consumption of acidic foods and beverages. Various gastrointestinal and eating disorders expose the dentition to frequent contacts with very acidic gastric content, which may lead to erosion. Whether these factors indeed lead, on a population scale, to a higher prevalence and incidence of erosion is yet to be established. This article summarizes the different aspects of the prevalence, pathology, etiology, assessment, prevention and treatment of dental erosion, and concludes with recommendations for future research.

  7. Biocompatibility of dental alloys

    Energy Technology Data Exchange (ETDEWEB)

    Braemer, W. [Heraeus Kulzer GmbH and Co. KG, Hanau (Germany)

    2001-10-01

    Modern dental alloys have been used for 50 years to produce prosthetic dental restorations. Generally, the crowns and frames of a prosthesis are prepared in dental alloys, and then veneered by feldspar ceramics or composites. In use, the alloys are exposed to the corrosive influence of saliva and bacteria. Metallic dental materials can be classified as precious and non-precious alloys. Precious alloys consist of gold, platinum, and small amounts of non-precious components such as copper, tin, or zinc. The non-precious alloys are based on either nickel or cobalt, alloyed with chrome, molybdenum, manganese, etc. Titanium is used as Grade 2 quality for dental purposes. As well as the dental casting alloys, high purity electroplated gold (99.8 wt.-%) is used in dental technology. This review discusses the corrosion behavior of metallic dental materials with saliva in ''in vitro'' tests and the influence of alloy components on bacteria (Lactobacillus casei and Streptococcus mutans). The test results show that alloys with high gold content, cobalt-based alloys, titanium, and electroplated gold are suitable for use as dental materials. (orig.)

  8. Surface assessment and modification of concrete using abrasive blasting

    Science.gov (United States)

    Millman, Lauren R.

    Composite systems are applied to concrete substrates to strengthen and extend the service life. Successful restoration or rehabilitation requires surface preparation prior to the application of the overlay. Surface coatings, waterproofing systems, and other external surface applications also require surface preparation prior to application. Abrasive blast media is often used to clean and uniformly roughen the substrate. The appropriate surface roughness is necessary to facilitate a strong bond between the existing substrate and overlay. Thus, surface modification using abrasive blast media (sand and dry ice), their respective environmental effects, surface roughness characterization prior to and after blasting, and the adhesion between the substrate and overlay are the focus of this dissertation. This dissertation is comprised of an introduction, a literature review, and four chapters, the first of which addresses the environmental effects due to abrasive blasting using sand, water, and dry ice. The assessment considered four response variables: carbon dioxide (CO2) emissions, fuel and energy consumption, and project duration. The results indicated that for sand blasting and water jetting, the primary factor contributing to environmental detriment was CO22 emissions from vehicular traffic near the construction site. The second chapter is an analysis of the International Concrete Repair Institute's (ICRI) concrete surface profiles (CSPs) using 3-D optical profilometry. The primary objective was to evaluate the suitability of approximating the 3-D surface (areal) parameters with those extracted from 2-D (linear) profiles. Four profile directions were considered: two diagonals, and lines parallel and transverse to the longitudinal direction of the mold. For any CSP mold, the estimation of the 3-D surface roughness using a 2-D linear profile resulted in underestimation and overestimation errors exceeding 50%, demonstrating the inadequacy of 2-D linear profiles to

  9. Treatment of gingival hyperpigmentation with rotary abrasive, scalpel, and laser techniques: A case series.

    Science.gov (United States)

    Murthy, M Bhanu; Kaur, Jasjit; Das, Rupali

    2012-10-01

    Melanin pigmentation often occurs in the gingiva as a result of an abnormal deposition of melanin, due to which the gums may appear black, but the principles, techniques, and management of the problems associated with gingival melanin pigmentation are still not fully established. Depigmentation procedures such as scalpel surgery, gingivectomy with free gingival autografting, electrosurgery, cryosurgery, chemical agents such as 90% phenol and 95% alcohol, abrasion with diamond bur, Nd: YAG laser, semiconductor diode laser, and CO2 laser have been employed for removal of melanin hyper pigmentation. The following case series describes three different surgical depigmentation techniques: scalpel surgery, abrasion with rotary abrasive, and a diode laser. Better results of depigmentation were achieved with diode laser than conventional scalpel and with rotary abrasion with respect to esthetics. The results point out that lasers are an effective and a safe means to removal of hyperpigmentation from the gingiva. Healing was uneventful and no repigmentation occurred.

  10. Abrasion resistance of biaxially oriented polypropylene films coated with nanocomposite hard coatings

    Science.gov (United States)

    Wang, Jing; Zhu, Yaofeng; Fu, Yaqin

    2013-11-01

    KMnO4-treated, functionalized, biaxially oriented polypropylene (BOPP) films coated with nano-silica hybrid material were synthesized. The abrasion resistance of the films was examined using a reciprocating fabric abrasion tester. Functional groups were confirmed by Fourier-transform infrared spectroscopy. Contact angle measurements were performed on the BOPP film surface to quantify the effectiveness of the functionalization. Results indicate that the abrasion resistance and roughness of the composite film were significantly affected by the modification of the BOPP film. Water surface contact angle of the modified BOPP films decreased from 90.1° to 71.4°,when KMnO4 concentration increased from 0 M to 0.25 M. Wettability of the BOPP films clearly improved after KMnO4 treatment. Abrasion resistance of the functionalized films coated with hybrid materials improved by 27.4% compared with that of the original film.

  11. MAGNETO-ABRASIVE MACHINING OF SURFACES FORMED BY ELECTROMAGNET SURFACING WITH PLASTIC DEFORMATION

    Directory of Open Access Journals (Sweden)

    Zh. A. Mrochek

    2011-01-01

    Full Text Available The paper presents investigation results pertaining to magneto-abrasive machining of product surfaces formed by electromagnet surfacing with a plastic deformation of P6M5K5 powder. 

  12. Machining of the Flat Surfaces with Abrasive-metallic Lapping Tools

    Institute of Scientific and Technical Information of China (English)

    Adam Barylski

    2004-01-01

    The constructional principle of abrasion metal disc is that abrasive insertions are spread uniformly on the working surface of a metal base. During lapping by means of such tools only the machining fluid is dosed and that by drop.Abrasive elements of circular shape pellets are produced by mixing boron carbide BC400 micrograins with electrographite components, the pellets were pressed with a load of about 12 kN. Next they were heated in furnace at about 520K for hours,then cooled together with the furnace. Tests were carried out on the making of circular abrasive insertions of which the main components were born carbide and micrograins of electric copper mixed the epoxide resins.

  13. Machining of the Flat Surfaces with Abrasive-metallic Lapping Tools

    Institute of Scientific and Technical Information of China (English)

    AdamBarylski

    2004-01-01

    The constructional principle of abrasion metal disc is that abrasive insertions are spread uniformly on the working surface of a metal base. During lapping by means of such tools only the machining fluid is dosed and that by drop. Abrasive elements of circular shape pellets are produced by mixing boron carbide BC400 micrograins with electrographite components, the pellets were pressed with a load of about 12 kN. Next they were heated in furnace at about 520K for hours, then cooled together with the furnace. Tests were carried out on the making of circular abrasive insertions of which the main components were born carbide and micrograins of electric copper mixed the epoxide resins.

  14. Surface roughness and gloss of current CAD/CAM resin composites before and after toothbrush abrasion.

    Science.gov (United States)

    Koizumi, Hiroyasu; Saiki, Osamu; Nogawa, Hiroshi; Hiraba, Haruto; Okazaki, Tomoyo; Matsumura, Hideo

    2015-01-01

    The purpose of this study was to evaluate the gloss and surface roughness behaviors of newly developed CAD/CAM composite blocks with different filler contents and characteristics. The gloss and surface roughness were quantified before and after a toothbrush dentifrice abrasion test; the results were compared to the gloss and surface roughness of a ceramic CAD/CAM block. Knoop hardness was determined before abrasion test. The results were analyzed by ANOVA, Tukey HSD, and Dunnett t test (pVita Enamic>Gradia block>Shofu Block HC, Lava Ultimate≥Katana Avencia block≥Cerasmart. After toothbrush abrasion, a significant difference in the gloss unit was detected between the Shofu Block HC material and the ceramic block. The Ra and Rz of the Cerasmart and Shofu Block HC materials were significantly larger than those of the ceramic block after toothbrush abrasion.

  15. Clarification of abrasive jet precision finishing with wheel as restraint mechanisms and experimental verification

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    According to the critical size ratio for the characteristic particle size to film thickness between grinding wheel and work, the machining mechanisms in abrasive jet precision finishing with grinding wheel as restraint can be categorized into four states, namely, two-body lapping, three-body polishing, abrasive jet machining and fluid hydrodynamic shear stress machining. The critical transition condition of two-body lapping to three-body polishing was analyzed. The single abrasive material removal models of two-body lapping, three-body polishing, abrasive jet finishing and fluid hydrodynamic shear stress machining were proposed. Experiments were performed in the refited plane grinding machine for theoretical modes verification. It was found that experimental results agreed with academic modes and the modes validity was verified.

  16. Study of kerf geometry of multilayers materials in abrasive water jet cutting process

    Directory of Open Access Journals (Sweden)

    Barabas Bogdan

    2017-01-01

    Full Text Available The use of abrasive jet cutting in case of multilayers materials, shows particularities and difficulties, due to different hardness and thickness of layers. This paper studies changes, occurred in the kerf geometry at passing of abrasive particles, through layers with different hardness and aims to establish a link between hardness and thickness of the layers and kerf geometry because processing accuracy is determined by the geometry of the cut. Thus, is proposed a novel algorithm based on minimization of angle of kerf, for optimization a cutting process in abrasive water jet technology, which can be utilized for materials with different hardness in layers. Direct effect of optimization of cutting consist in increasing efficiency, dimensional precision, traverse velocity, and decreasing the amount of used abrasive garnet.

  17. Abrasive wear property of laser melting/deposited Ti2Ni/TiNi intermetallic alloy

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    A wear resistant intermetallic alloy consisting of TiNi primary dendrites and Ti2Ni matrix was fabricated by the laser melting deposition manufacturing process. Wear resistance of Ti2Ni/TiNi alloy was evaluated on an abrasive wear tester at room temperature under the different loads. The results show that the intermetallic alloy suffers more abrasive wear attack under low wear test load of 7, 13 and 25 N than high-chromium cast-iron. However, the intermetallic alloy exhibits better wear resistance under wear test load of 49 N. Abrasive wear of the laser melting deposition Ti2Ni/TiNi alloy is governed by micro-cutting and plowing.Pseudoelasticity of TiNi plays an active role in contributing to abrasive wear resistance.

  18. The effect on cast post dimensions of casting investment and airborne particle abrasion.

    Science.gov (United States)

    Hashem, Danya; German, Matthew J; Wassell, Robert W

    2011-09-01

    Cast posts can sometimes prove difficult to seat fully during fitting. This study compared two different liquid/water dilutions for phosphate bonded investment and the effect of controlled airborne particle abrasion on resulting post diameter. After measuring polymeric post patterns (n = 18), 3 groups were invested using concentrated solution and 3 groups using dilute solution. After casting they were weighed and remeasured then exposed to airborne particle abrasion. Both solutions produced oversized cast posts. Mean diameter reduction during airborne particle abrasion was 8 microm/10s taking an average of 41s to reach precast size. Where a post pattern fits tightly, airborne particle abrasion for 70s should reduce the casting sufficiently to accommodate the cement lute.

  19. Drawing Light-fields: Hand-drawn Approaches to Abrasion Holography

    Science.gov (United States)

    Duke, T.

    2013-02-01

    Abrasion holography has received little attention since the technique was described by William J. Beaty in the early 1990's. In this paper the limitations of abrasion holography are explored, and new approaches are presented which expand the possibilities of the medium. New tools presented here offer new possibilities to the artist wishing to draw holograms by hand. Methods are described by which complex curves and organic forms can be constructed by hand more easily and intuitively than previously described. In an analysis of reconstruction lighting and viewing geometries, new solutions to reduce or eliminate distortions are suggested. Various tools, materials, and scratch geometries are considered for optimum 3D illusion. A new class of abrasion holograms is presented that use elliptical, hypotrochoidal, and epitrochoidal scratch geometries, exhibiting novel animation effects. In conclusion, a method for embossing abrasion holograms with the aid of an etching press is described.

  20. INVESTIGATION ON NEW TYPE OF DOUBLY BLENDING ABRASIVE WATER JET NOZZLE SYSTEM WITH HIGHER PERFORMANCE

    Institute of Scientific and Technical Information of China (English)

    ZHU Pailong; ZHOU Jinjin; TANG Dianbo

    2006-01-01

    Based on the two existing abrasive water-jet(AWJ) systems, the dia-jet (or pre-jet) and the post-jet, a new type of abrasive water-jet system is put forward, which combines the dia-jet's advantage, low operating system pressure, slender stream jet, and more concentrative abrasive in the blended stream, with merits of post-jet, the less sophisticate apparatus, successive supply of abrasives.The theoretic analysis is brought out in detail, and the nozzle system structure is concisely illustrated.Its relevant experiment results are demonstrated, proving that this new system is effective in various aspects, enlarging penetrating capability without raising system pressure, saving machining power supply, lessening energy loss, etc.

  1. Abrasion and deformed layer formation of manganese-zinc ferrite in sliding contact with lapping tapes

    Science.gov (United States)

    Miyoshi, K.; Buckley, D. H.; Tanaka, K.

    1986-01-01

    Wear experiments were conducted using replication electron microscopy and reflection electron diffraction to study abrasion and the deformed layers produced in single-crystal Mn-Zn ferrite simulated heads during contact with lapping tapes. The crystaline state of the head is changed drastically during the abrasion process. Crystalline states ranging from nearly amorphous to highly textured polycrystalline can be produced on the wear surface of a single-crystal Mn-Zn ferrite head. The total thickness of the deformed layer was approximately 0.8 microns. This thickness increased as the load and abrasive grit size increased. The anisotropic wear of the ferrite was found to be inversely proportional to the hardness of the wear surface. The wear was lower in the order 211 111 10 0110. The wear of the ferrite increased markedly with an increase in sliding velocity and abrasive grit size.

  2. A Study of effect of Process Parameters of Abrasive jet machining

    Directory of Open Access Journals (Sweden)

    Jagtar Singh

    2011-01-01

    Full Text Available As Abrasive jet machining (AJM is similar to sand blasting and effectively removes hard and brittle materials. AJM has been applied to rough working such as deburring and rough finishing. With the increase of needs for machining of ceramics, semiconductors, electronic devices and L.C.D., AJM has become a useful technique for micromachining. This paper deals with various experiments which were conducted to assess the influence of abrasive jet machining (AJM process parameters on material removal rate and diameter of holes of glass plates using aluminum oxide type of abrasive particles. The experimental results of the present work are used to discuss thevalidity of proposed model as well as the other models. With the increase in nozzle tip distance (NTD, the top surface diameter and bottom surface diameter of hole increases as it is in general observation of abrasive jet machining process. As the pressure increases, the material removal rate (MRR is also increased.

  3. Accuracy in dental medicine, a new way to measure trueness and precision.

    Science.gov (United States)

    Ender, Andreas; Mehl, Albert

    2014-04-29

    Reference scanners are used in dental medicine to verify a lot of procedures. The main interest is to verify impression methods as they serve as a base for dental restorations. The current limitation of many reference scanners is the lack of accuracy scanning large objects like full dental arches, or the limited possibility to assess detailed tooth surfaces. A new reference scanner, based on focus variation scanning technique, was evaluated with regards to highest local and general accuracy. A specific scanning protocol was tested to scan original tooth surface from dental impressions. Also, different model materials were verified. The results showed a high scanning accuracy of the reference scanner with a mean deviation of 5.3 ± 1.1 µm for trueness and 1.6 ± 0.6 µm for precision in case of full arch scans. Current dental impression methods showed much higher deviations (trueness: 20.4 ± 2.2 µm, precision: 12.5 ± 2.5 µm) than the internal scanning accuracy of the reference scanner. Smaller objects like single tooth surface can be scanned with an even higher accuracy, enabling the system to assess erosive and abrasive tooth surface loss. The reference scanner can be used to measure differences for a lot of dental research fields. The different magnification levels combined with a high local and general accuracy can be used to assess changes of single teeth or restorations up to full arch changes.

  4. Education About Dental Hygienists' Roles in Public Dental Prevention Programs: Dental and Dental Hygiene Students' and Faculty Members' and Dental Hygienists' Perspectives.

    Science.gov (United States)

    Pervez, Anushey; Kinney, Janet S; Gwozdek, Anne; Farrell, Christine M; Inglehart, Marita R

    2016-09-01

    In 2005, Public Act No. 161 (PA 161) was passed in Michigan, allowing dental hygienists to practice in approved public dental prevention programs to provide services for underserved populations while utilizing a collaborative agreement with a supervising dentist. The aims of this study were to assess how well dental and dental hygiene students and faculty members and practicing dental hygienists have been educated about PA 161, what attitudes and knowledge about the act they have, and how interested they are in additional education about it. University of Michigan dental and dental hygiene students and faculty members, students in other Michigan dental hygiene programs, and dental hygienists in the state were surveyed. Respondents (response rate) were 160 dental students (50%), 63 dental hygiene students (82%), 30 dental faculty members (26%), and 12 dental hygiene faculty members (52%) at the University of Michigan; 143 dental hygiene students in other programs (20%); and 95 members of the Michigan Dental Hygienists' Association (10%). The results showed that the dental students were less educated about PA 161 than the dental hygiene students, and the dental faculty members were less informed than the dental hygiene faculty members and dental hygienists. Responding dental hygiene faculty members and dental hygienists had more positive attitudes about PA 161 than did the students and dental faculty members. Most of the dental hygiene faculty members and dental hygienists knew a person providing services in a PA 161 program. Most dental hygiene students, faculty members, and dental hygienists wanted more education about PA 161. Overall, the better educated about the program the respondents were, the more positive their attitudes, and the more interested they were in learning more.

  5. Chemical Mechanical Polishing of Glass Substrate with α-Alumina-g-Polystyrene Sulfonic Acid Composite Abrasive

    Institute of Scientific and Technical Information of China (English)

    LEI Hong; BU Naijing; ZHANG Zefang; CHEN Ruling

    2010-01-01

    Abrasive is the one of key influencing factors during chemical mechanical polishing(CMP) process. Currently, α-Alumina (α-Al2O3) particle, as a kind of abrasive, has been widely used in CMP slurries, but their high hardness and poor dispersion stability often lead to more surface defects. After being polished with composite particles, the surface defects of work pieces decrease obviously. So the composite particles as abrasives in slurry have been paid more attention. In order to reduce defect caused by pure α-Al2O3 abrasive, α-alumina-g-polystyrene sulfonic acid (α-Al2O3-g-PSS) composite abrasive was prepared by surface graft polymerization. The composition, structure and morphology of the product were characterized by Fourier transform infrared spectroscopy(FTIR), X-ray photoelectron spectroscopy(XPS), time-of-flight secondary ion mass spectroscopy(TOF-SIMS), and scanning electron microscopy(SEM), respectively. The results show that polystyrene sulfonic acid grafts onto α-Al2O3, and has well dispersibility. Then, the chemical mechanical polishing performances of the composite abrasive on glass substrate were investigated with a SPEEDFAM-16B-4M CMP machine. Atomic force microscopy(AFM) images indicate that the average roughness of the polished glass substrate surface can be decreased from 0.835 nm for pure α-Al2O3 abrasive to 0.583 nm for prepared α-Al2O3-g-PSS core-shell abrasive. The research provides a new and effect way to improve the surface qualities during CMP.

  6. The influence of mixing water and abrasives on the quality of machined surface

    Directory of Open Access Journals (Sweden)

    A. Stoić

    2014-04-01

    Full Text Available This paper shows the impact of mixing water and abrasives in water jet cutting process on the quality of the machined surface. The tests were done with polymer material SIPAS, where the influence of cutting parameters was researched (cutting pressure, cutting feed and abrasive mass flow. The surface roughness was measured on several zones, regarding the depth of materials, because the roughness is increased with the material thickness.

  7. Multi-objective Optimization of Process Performances when Cutting Carbon Steel with Abrasive Water Jet

    Directory of Open Access Journals (Sweden)

    M. Radovanović

    2016-12-01

    Full Text Available Multi-objective optimization of process performances (perpendicularity deviation, surface roughness and productivity when cutting carbon steel EN S235 with abrasive water jet is presented in this paper. Cutting factors (abrasive flow rate, traverse rate and standoff distance were determined when perpendicularity deviation and surface roughness are minimal and productivity is maximal. Multi-objective genetic algorithm (MOGA was used for the determination set of nondominated optimal points, known as Pareto front.

  8. Ice Abrasion and Bond Testing of Repair Mortars and High Performance Concrete

    OpenAIRE

    Kirkhaug, Joakim Rydningen

    2013-01-01

    The purpose of this thesis has been to investigate ice abrasion properties for three different repair mortars, and evaluate their behavior and properties in relation to a typical B60 offshore concrete and a B70 concrete. Bond strength to a B60 concrete has been tested for all mortars. To increase understanding and knowledge in the field of research, a literature study was made. Roughness parameters, bond strength properties and parameters affecting ice abrasion resistance were reviewed. Testi...

  9. Examination of Wetting by Liquid Zinc of Steel Sheets Following Various Kinds of Abrasive Blasting

    Directory of Open Access Journals (Sweden)

    Cecotka M.

    2016-06-01

    Full Text Available Abrasive blasting is one of the methods of surface working before hot-dip zinc-coating. It allows not only to remove products of corrosion from the surface, but it also affects the quality of the zinc coating applied later, thereby affecting wettability of surface being zinc-coated. The surface working can be done with different types of abrasive material.

  10. Release of copper-amended particles from micronized copper-pressure-treated wood during mechanical abrasion

    OpenAIRE

    Civardi, Chiara; Schlagenhauf, Lukas; Kaiser, Jean-Pierre; Hirsch, Cordula; Mucchino, Claudio; Wichser, Adrian; Wick, Peter; Schwarze, Francis W. M. R.

    2016-01-01

    Background We investigated the particles released due to abrasion of wood surfaces pressure-treated with micronized copper azole (MCA) wood preservative and we gathered preliminary data on its in vitro cytotoxicity for lung cells. The data were compared with particles released after abrasion of untreated, water (0% MCA)-pressure-treated, chromated copper (CC)-pressure-treated wood, and varnished wood. Size, morphology, and composition of the released particles were analyzed. Results Our resul...

  11. Neutralization of potential land mine hazards by abrasive waterjet use

    Science.gov (United States)

    Summers, David A.; Fossey, Robert D.; Thompson, S. J.

    1998-09-01

    A method of neutralizing landmines in which the integrity of the surrounding terrain is retained is herein described. High pressure waterjets which can be used to detect the presence of landmines can then be used to remove the soil and other cover in a plane immediately adjacent to and around the mine so that the side of the mine can be visually inspected through a remote television camera. At that time the flow of water is channeled through a line in which small particles of sand are added to the waterjet which is at a pressure of between 3,000 and 10,000 psi depending on the device which is used. Jet flow rates are on the order of 5 gpm depending on the nozzle configuration used. By bringing this abrasive stream in along a lateral plane through the mine it is possible to intersect, and neutralize, the fusing systems most likely to be used to initiate the charge, in a single pass. At higher flow rates, as the cut is made the jet will generate significant turbulence in the mine body, sufficient to remove a considerable quantity of the explosive which is resident within the mine at the same time as the mine is being dissected. The precision of cut achievable is shown by the longitudinal cutting into two parts of live detonators, as well as representative mine bodies.

  12. Microstructure formation and properties of abrasion resistant cast steel

    Directory of Open Access Journals (Sweden)

    S. Parzych

    2010-01-01

    Full Text Available The so-called adamitic cast steels are characterised by a high abrasion resistance. These cast steels are of a pearlitic matrix with uniformly distributed hypereutectoid cementite precipitates. Apart from hypereutectoid cementite very often transformed ledeburite also occurs in the microstructure of these cast steels. Such cast steels contain chromium (app. 1 % and nickel (app. 0.5 % as alloy additions and sometimes their silicon content is increased. The presence of molybdenum is also permissible (app. 0.4 %. The basic problem in application of these steels for structural elements constitutes their insufficient crack resistance. An improvement of mechanical properties by changes of morphology of hypereutectoid cementite and transformed ledeburite precipitates by means of the heat treatment application was the aim of this study. G200CrNiMo4-3-3 cast steel was the investigated material. Changes in the morphology of hypereutectoid cementite and transformed ledeburite obtained due to the heat treatment are described in detail in the present paper. An influence of the microstructure changes on impact toughness of the investigated cast steel is presented. Investigations performed within this study will serve for the microstructure optimisation on account of functional qualities of this cast steel.

  13. Laboratory Measurements of Particulate Matter Concentrations from Asphalt Pavement Abrasion

    Science.gov (United States)

    Fullová, Daša; Đurčanská, Daniela

    2016-12-01

    The issue of emissions from road traffic is compounded by the fact that the number of vehicles and driven kilometres increase each year. Road traffic is one of the main sources of particulate matter and traffic volume is still increasing and has unpleasant impact on longevity of the pavements and the environment. Vehicle motions cause mechanical wearing of the asphalt pavement surface - wearing course by vehicle tyres. The contribution deals with abrasion of bituminous wearing courses of pavements. The asphalt mixtures of wearing courses are compared in terms of mechanically separated particulate matter. The samples of asphalt mixtures were rutted in wheel tracking machine. The particulate matter measurements were performed in laboratory conditions. The experimental laboratory measurements make it possible to sample particulates without contamination from exhaust emissions, abraded particles from vehicles, resuspension of road dust and climate affects. The contribution offers partial results of measurements on six trial samples of asphalt mixtures with different composition. It presents particulate matter morphology and the comparison of rutted asphalt samples in terms of PM mass concentrations and chemical composition.

  14. Laboratory Measurements of Particulate Matter Concentrations from Asphalt Pavement Abrasion

    Directory of Open Access Journals (Sweden)

    Fullová Daša

    2016-12-01

    Full Text Available The issue of emissions from road traffic is compounded by the fact that the number of vehicles and driven kilometres increase each year. Road traffic is one of the main sources of particulate matter and traffic volume is still increasing and has unpleasant impact on longevity of the pavements and the environment. Vehicle motions cause mechanical wearing of the asphalt pavement surface - wearing course by vehicle tyres. The contribution deals with abrasion of bituminous wearing courses of pavements. The asphalt mixtures of wearing courses are compared in terms of mechanically separated particulate matter. The samples of asphalt mixtures were rutted in wheel tracking machine. The particulate matter measurements were performed in laboratory conditions. The experimental laboratory measurements make it possible to sample particulates without contamination from exhaust emissions, abraded particles from vehicles, resuspension of road dust and climate affects. The contribution offers partial results of measurements on six trial samples of asphalt mixtures with different composition. It presents particulate matter morphology and the comparison of rutted asphalt samples in terms of PM mass concentrations and chemical composition.

  15. Dynamic Mechanical Analysis and Three-Body Abrasive Wear Behaviour of Thermoplastic Copolyester Elastomer Composites

    Directory of Open Access Journals (Sweden)

    Hemanth Rajashekaraiah

    2014-01-01

    Full Text Available Various amounts of short fibers (glass and carbon and particulate fillers like polytetrafluoroethylene (PTFE, silicon carbide (SiC, and alumina (Al2O3 were systematically introduced into the thermoplastic copolyester elastomer (TCE matrix for reinforcement purpose. The mechanical properties such as storage modulus, loss modulus, and Tan δ by dynamic mechanical analysis (DMA and three-body abrasive wear performance on a dry sand rubber wheel abrasion tester have been investigated. For abrasive wear study, the experiments were planned according to L27 orthogonal array by considering three factors and three levels. The complex moduli for TCE hybrid composites were pushed to a higher level relative to the TCE filled PTFE composite. At lower temperatures (in the glassy region, the storage modulus increases with increase in wt.% of reinforcement (fiber + fillers and the value is maximum for the composite with 40 wt.% reinforcement. The loss modulus and damping peaks were also found to be higher by the incorporation of SiC and Al2O3 microfillers. The routine abrasive wear test results indicated that TCE filled PTFE composite exhibited better abrasion resistance. Improvements in the abrasion resistance, however, have not been achieved by short-fiber and particlaute filler reinforcements. From the Taguchi’s experimental findings, optimal combination of control factors were obtained for minimum wear volume and also predictive correlations were proposed. Further, the worn surface morphology of the samples was discussed.

  16. Microstructure and abrasion wear behavior of Ni-based laser cladding alloy layer at high temperature

    Institute of Scientific and Technical Information of China (English)

    LIU Yong; LIU Su-qin; WANG Shun-xing

    2005-01-01

    Ni-based alloy coating on 21-4-N heat-resistant steel was prepared using CO2 laser, and the high-temperature abrasion wear was tested. The microstructure of this cladding layer and its abrasion wear behavior at high temperature by changing compositions and temperatures were investigated by means of optical microscope and scanning electron microscope. Among the three compositions of cladding layer, i.e. Ni21+20%WC+0.5%CeO2, Ni25+20%WC+0.5%CeO2 and Ni60+20%WC+0.5%CeO2, the experimental results show that Ni21+20%WC+0.5%CeO2 cladding layer is made up of finer grains, and presents the best abrasion wear behavior at high temperature. The wear pattern of laser cladding layer is mainly grain abrasion at lower temperature, and it would be changed to adhesive abrasion and oxide abrasion at higher temperature.

  17. A light-scattering study of Al2O3 abrasives of various grit sizes

    Science.gov (United States)

    Heinson, Yuli W.; Chakrabarti, Amitabha; Sorensen, Christopher M.

    2016-09-01

    We report light scattering phase function measurements for irregularly shaped Al2O3 abrasive powders of various grit sizes. Q-space analysis is applied to the angular scattering to reveal a forward scattering regime, Guinier regime, power law regime with quantifiable exponents, and an enhanced backscattering regime. The exponents of the power laws for Al2O3 abrasives decrease with increasing internal coupling parameter ρ ‧ , which is in agreement with previous observations for other irregular particles. Unlike other dust particles previously studied showing single power laws under Q-space analysis, the largest three abrasives, for which ρ ‧ ≳ 100 , showed a kink in the power law, which is possibly due to the higher degree of symmetry for the abrasives than for all the particles studied previously. Direct comparison of the 1200, 1000, and 800 grit abrasive scattering to scattering by corresponding spheres shows that the scatterings approximately coincide at the spherical particle qR ≃ ρ ‧ crossover point. Furthermore, the scattering at the maximum qR = 2 kR by the irregularly shaped abrasives is close to the geometric centers of the glories of the spheres.

  18. Dental Charting. Student's Manual.

    Science.gov (United States)

    Weaver, Trudy Karlene; Apfel, Maura

    This manual is part of a series dealing with skills and information needed by students in dental assisting. The individualized student materials are suitable for classroom, laboratory, or cooperative training programs. This student manual contains four units covering the following topics: dental anatomical terminology; tooth numbering systems;…

  19. Dental emergency rates at two expeditionary medical support facilities supporting operations enduring and Iraqi Freedom.

    Science.gov (United States)

    Dunn, William J; Langsten, Robert E; Flores, Salvador; Fandell, Jay E

    2004-07-01

    This study reports dental emergency rates and distribution of causes of dental emergencies at two expeditionary medical support facilities supporting operations Enduring Freedom/ Iraqi Freedom. A retrospective cohort analysis of 9948 soldiers deployed to Prince Sultan Air Base, Kingdom of Saudi Arabia, and 1467 soldiers at Baghdad International Airport, Iraq, was accomplished from a phased deployment from January 2003 to September 2003. Procedures were divided into 11 categories: endodontic, extraction of teeth other than third molars, extraction of third molar teeth, restoration of teeth (caries), restoration of broken teeth (not caries), orthodontic bracket/wire problem, sensitive teeth, temperomandibular pain, periodontal, oral pathology, and prosthodontic. The dental emergency rates for Prince Sultan Air Base and Baghdad International Airport were 153 and 145 dental emergencies per 1000 soldiers per year, respectively. Most of the emergencies were because of dental caries. Pain from third molars was the second most common reason for visiting the dental clinic.

  20. On the Friction and Wear Behaviors of Dental Machinable Porcelain

    Institute of Scientific and Technical Information of China (English)

    YU Hai-yang; ZHOU Zhong-rong; CAI Zhen-Bing

    2004-01-01

    In order to well design tribosystems of dental CAD-CAM restorations, an understanding of the tribological mechanisms of dental machinable porcelain are essential. The friction and wear behavior of new generation industrially prefabricated Cerec Vitablocs Mark Ⅱ against uniform Si3N4 ball has been performed using a small amplitude reciprocating apparatus under simulating oral conditions. The loads of 10-40 N, reciprocating amplitudes of 100-500 μm, frequencies of 1-4 Hz and two lubrications (no / artificial saliva lubrication) were selected. Tests lasting up to 10 000 cycles were conducted. The results show that Cerec Vitablocs Mark Ⅱ record a friction coefficient of 0.55-0.84. Artificial saliva plays a lubricant effect during wear process. Among three parameters of the test on friction coefficient and wear depth of dental machinable porcelains, the load effect is prominent. Abrasive wear is the main wear mechanism, but brittle cracks and delamination are more popular especially under unlubricated friction.

  1. On the Friction and Wear Behaviors of Dental Machinable Porcelain

    Institute of Scientific and Technical Information of China (English)

    YUHai-yang; ZHOUZhong-rong; CAIZhen-Bing

    2004-01-01

    In order to well design tribosystems of dental CAD-CAM restorations, an understanding of the tribological mechanisms of dental machinable porcelain are essential. The friction and wear behavior of new generation industrially prefabricated Cerec Vitablocs Mark II against uniform Si3N4ball has been performed using a small amplitude reciprocating apparatus under simulating oral conditions. The loads of 10-40N, reciprocating amplitudes of 100-500μm, frequencies of 1-4Hz and two lubrications (no / artificial saliva lubrication) were selected. Tests lasting up to 10 000 cycles were conducted. The results show that Cerec Vitablocs Mark Ⅱ record a friction coefficient of 0.55-0.84. Artificial saliva plays a lubricant effect during wear process. Among three parameters of the test on friction coefficient and wear depth of dental machinable porcelains, the load effect is prominent. Abrasive wear is the main wear mechanism, but brittle cracks and delamination are more popular especially under unlubricated friction.

  2. Titanium Nitride and Nitrogen Ion Implanted Coated Dental Materials

    Directory of Open Access Journals (Sweden)

    David W. Berzins

    2012-07-01

    Full Text Available Titanium nitride and/or nitrogen ion implanted coated dental materials have been investigated since the mid-1980s and considered in various applications in dentistry such as implants, abutments, orthodontic wires, endodontic files, periodontal/oral hygiene instruments, and casting alloys for fixed restorations. Multiple methodologies have been employed to create the coatings, but detailed structural analysis of the coatings is generally lacking in the dental literature. Depending on application, the purpose of the coating is to provide increased surface hardness, abrasion/wear resistance, esthetics, and corrosion resistance, lower friction, as well as greater beneficial interaction with adjacent biological and material substrates. While many studies have reported on the achievement of these properties, a consensus is not always clear. Additionally, few studies have been conducted to assess the efficacy of the coatings in a clinical setting. Overall, titanium nitride and/or nitrogen ion implanted coated dental materials potentially offer advantages over uncoated counterparts, but more investigation is needed to document the structure of the coatings and their clinical effectiveness.

  3. Various Effects of Sandblasting of Dental Restorative Materials.

    Directory of Open Access Journals (Sweden)

    Goro Nishigawa

    Full Text Available Sandblasting particles which remain on the surfaces of dental restorations are removed prior to cementation. It is probable that adhesive strength between luting material and sandblasting particle remnants might exceed that with restorative material. If that being the case, blasting particles adhere to sandblasted material surface could be instrumental to increasing adhesive strength like underlying bonding mechanism between luting material and silanized particles of tribochemical silica coating-treated surface. We hypothesize that ultrasonic cleaning of bonding surfaces, which were pretreated with sandblasting, may affect adhesive strength of a resin luting material to dental restorative materials.We therefore observed adhesive strength of resin luting material to aluminum oxide was greater than those to zirconia ceramic and cobalt-chromium alloy beforehand. To measure the shear bond strengths of resin luting material to zirconia ceramic and cobalt-chromium alloy, forty specimens of each restorative material were prepared. Bonding surfaces were polished with silicon abrasive paper and then treated with sandblasting. For each restorative material, 40 sandblasted specimens were equally divided into two groups: ultrasonic cleaning (USC group and non-ultrasonic cleaning (NUSC group. After resin luting material was polymerized on bonding surface, shear test was performed to evaluate effect of ultrasonic cleaning of bonding surfaces pretreated with sandblasting on bond strength.For both zirconia ceramic and cobalt-chromium alloy, NUSC group showed significantly higher shear bond strength than USC group.Ultrasonic cleaning of dental restorations after sandblasting should be avoided to retain improved bonding between these materials.

  4. Detection of Common Dental Diseases by Dental Hygiene-Therapists

    OpenAIRE

    Macey, Richard John

    2016-01-01

    Thesis submitted to the University of Manchester by Richard Macey for the Degree of Doctor of Philosophy entitled “Detection of Common Dental Diseases by Dental Hygiene-Therapists”, February 2016.Many adult patients that attend NHS dental practices on a regular basis are asymptomatic and do not need any further treatment other than a routine dental examination (“check-up”). As the oral health of the adult population is predicted to improve further, using the General Dental Practitioner to und...

  5. Health Instruction Packages: Permanent Teeth, Dental Deposits, and Dental Instruments. Dientes Permanentes, Depositos Dentales y Instrumentos Dentales.

    Science.gov (United States)

    Lind, Patricia; Germano, Catherine

    These five learning modules use text interspersed with illustrations and reinforcement exercises to instruct dental aide and dental hygiene students about jaw bones and gums, dental deposits, and dental instruments. The first four modules were prepared by Patricia Lind in both Spanish and English. "The Gum and Bone of Permanent Teeth"…

  6. Zirconia as a Dental Biomaterial

    Directory of Open Access Journals (Sweden)

    Alvaro Della Bona

    2015-08-01

    Full Text Available Ceramics are very important in the science of dental biomaterials. Among all dental ceramics, zirconia is in evidence as a dental biomaterial and it is the material of choice in contemporary restorative dentistry. Zirconia has been applied as structural material for dental bridges, crowns, inserts, and implants, mostly because of its biocompatibility, high fracture toughness, and radiopacity. However, the clinical success of restorative dentistry has to consider the adhesion to different substrates, which has offered a great challenge to dental zirconia research and development. This study characterizes zirconia as a dental biomaterial, presenting the current consensus and challenges to its dental applications.

  7. Behavior of HVOF WC-10Co4Cr Coatings with Different Carbide Size in Fine and Coarse Particle Abrasion

    Science.gov (United States)

    Ghabchi, Arash; Varis, Tommi; Turunen, Erja; Suhonen, Tomi; Liu, Xuwen; Hannula, S.-P.

    2010-01-01

    A modified ASTM G 65 rubber wheel test was employed in wet and dry conditions using 220 nm titania particles and 368 μm sand particles, respectively. Both tests were conducted on WC-CoCr coatings produced with two powders with different carbide grain sizes (conventional and sub-micron) to address the effect of carbide size and abrasive medium characteristics on the wear performance. The same spot before and after the wet abrasion wear testing was analyzed in detail using SEM to visualize wear mechanisms. It was shown that the wear mechanism depends on the relative size of the carbide and abrasive particles. Wear mechanisms in dry sand abrasion were studied by analyzing the single scratches formed by individual abrasive particles. Interaction of surface open porosity with moving abrasive particles causes formation of single scratches. By tailoring the carbide size, the wear performance can be improved.

  8. Performance of Flame Sprayed Ni-WC Coating under Abrasive Wear Conditions

    Science.gov (United States)

    Harsha, S.; Dwivedi, D. K.; Agarwal, A.

    2008-02-01

    This paper describes the influence of a post spray heat treatment on the microstructure, microhardness and abrasive wear behavior of the flame sprayed Ni-WC (EWAC 1002 ET) coating deposited on the mild steel. Coatings were deposited by using an oxy-acetylene flame spraying torch (Superjet Eutalloy L & T, India). The wear behavior of the coating was evaluated using a pin on disc wear system against SiC abrasive medium of 120 and 600 grades at 5, 10, 15, and 20 N normal load. Results revealed that the influence of normal load on wear is governed by the microstructure, hardness and abrasive grit size. The heat treatment increased average microhardness of the coating. However, it was found that the hardness does not correctly indicate the abrasive wear resistance of Ni-WC coating in an as sprayed and heat treated condition. The heat treatment of the coating improved its abrasive wear resistance against fine abrasive medium while the wear resistance against coarse abrasive was found to be a function of a normal load. At low-normal load (5 and 10 N) the heat treated coating showed lower-wear rate than as spayed coating while at high-normal loads (15 and 20 N) heat treated coating was subjected to higher-wear rate than as sprayed coating. In general, an increase in normal load increased the wear rate. The scanning electron microscopy study indicated that the wear largely takes place by groove formation and scoring of eutectic matrix and the fragmentation of the carbide particles.

  9. Analytical method for softness abrasive flow field based on discrete phase model

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    Aiming at the problem of difficult contact finishing for mini structural surface in course of mould manufacturing,a new no-tool precision machining method based on soft abrasive flow machining (SAFM) was proposed. It allocated restrained component near surface machined,constituted restrained abrasive flow passage,and made the surface become a segment of passage wall. It could control turbulence abrasive flow in restrained passage,realize micro cutting for passage wall,and utilize the irregular motion of abrasive flow to eliminate the mono-directional marks on machined surfaces,and the precision could reach the specular level. A two-phase dynamic model of abrasive flow oriented to SAFM combined with discrete phase model (DPM) was established,the law of two-phase flow motion and the related physical parameters was obtained by corresponding numerical simulation method,and the mechanism of precision machining in SAFM was discussed. Simulation results show that the abrasive flow machining process mainly appears as translation of ablating location with the influence by granular pressure,and as the variation of machining efficiency with the influence by near-wall particle velocity. Thus via control of the inlet velocity and its corresponding machining time,it is supposed to work out the machining process according to the machining requirements by using the Preston equation to seek the relationship among velocity,pressure and material removing rate. By tracking near-wall particles,it can be confirmed that the movement of near-wall abrasive particles is similar to stream-wise vortices. The cutting traces on workpiece surfaces assume disorderly arrangement,so the feasibility of the SAFM method can be reaffirmed.

  10. Multiphase Flow and Wear in the Cutting Head of Ultra-high Pressure Abrasive Water Jet

    Institute of Scientific and Technical Information of China (English)

    YANG Minguan; WANG Yuli; KANG Can; YU Feng

    2009-01-01

    Abrasive water jet cutting technology is widely applied in the materials processing today and attracts great attention from scholars, but many phenomena concerned are not well understood, especially in the internal jet flow of the cutting head at the condition of ultra-high pressure. The multiphase flow in the cutting head is numerically simulated to study the abrasive motion mechanism and wear inside the cutting head at the pressure beyond 300 Mpa. Visible predictions of the particles trajectories and wear rate in the cutting head are presented. The influences of the abrasive physical properties, size of the jewel orifice and the operating pressure on the trajectories are discussed. Based on the simulation, a wear experiment is carried out under the corresponding pressures. The simulation and experimental results show that the flow in the mixing chamber is composed of the jet core zone and the disturbance zone, both affect the particles trajectories. The mixing efficiency drops with the increase of the abrasive granularity. The abrasive density determines the response of particles to the effects of different flow zones, the abrasive with medium density gives the best general performance. Increasing the operating pressure or using the jewel with a smaller orifice improves the coherency of particles trajectories but increases the wear rate of the jewel holder at the same time. Walls of the jewel holder, the entrance of the mixing chamber and the convergence part of the mixing tube are subject to wear out. The computational and experimental results give a qualitative consistency which proves that this numerical method can provide a reliable and visible cognition of the flow characteristics of ultra-high pressure abrasive water jet. The investigation is benefit for improving the machining properties of water jet cutting systems and the optimization design of the cutting head.

  11. Utilization of radiometric method in evaluation of wear on human dental enamel in vitro by dental porcelain glazed and polished; Utilizacao do metodo radiometrico na avaliacao in vitro do desgaste provocado ao esmalte dental humano por porcelanas dentais glazeadas e polidas

    Energy Technology Data Exchange (ETDEWEB)

    Adachi, Lena Katekawa; Campos, Tomie Nakakuki de; Adachi, Eduardo Makoto [Sao Paulo Univ., SP (Brazil). Faculdade de Odontologia. Dept. de Protese]. E-mail: katekawa@usp.br; Saiki, Mitiko [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil)]. E-mail: mitiko@curiango.ipen.br

    2005-07-01

    The dental porcelain is a material commonly used in prosthesis. Disadvantages of dental porcelain use include possibility to cause tooth or dental materials wear. Before its use in the mouth, surfaces are treated with polishing and/or glazing. This research used the radiometric method to verify the influence of these surface treatments on the porcelains of commercial brands: Ceramco II, Noritake and Finesse. This method was originally developed for dentifrice abrasiveness evaluation. Five specimens of dental enamel and 10 specimens of each porcelain (5 glazed, 5 polished) were used. The dental enamel was flattened and irradiated with neutrons from the IEA-R1 (IPEN/CNEN) nuclear reactor. Then it was weared by each porcelain in sliding motion, with water. After 2,500 cycles for each porcelain specimen, the released enamel residue was measured. The enamel wear was evaluated by measuring beta activity of {sup 32}P transferred to water from the irradiated tooth. Results varied from 2.57 to 5.81 {mu}g of enamel /mm{sup 2} weared surface. There was no statistical difference ({alpha}=0.05) between dental enamel wear caused by the same porcelains glazed or polished. The results suggest that adequate surface finishing depend on the type of dental porcelain. (author)

  12. Equine dental advances.

    Science.gov (United States)

    Greene, S K

    2001-08-01

    The reintroduction and development of safe motorized instruments, the increased availability of continuing education, and the understanding and implementation of appropriate procedures allow practitioners to provide better dental care. Veterinarians realize that sedation, analgesia, a full-mouth speculum, and proper instrumentation are necessary to provide these services. Continued instrument design, future research, and new treatment and prophylactic protocols should have a positive impact on the future of equine dental health. New and rediscovered procedures for equilibrating equine occlusion are allowing horses to masticate more efficiently, carry a bit more comfortably, and experience improved performance. The horse, the horse owner, and the veterinary profession all benefit from providing complete equine dental care.

  13. Dental pulp stem cells

    DEFF Research Database (Denmark)

    Ashri, N. Y.; Ajlan, S. A.; Aldahmash, Abdullah M.

    2015-01-01

    scaffold, and guided through signaling molecules. Dental pulp stem cells have been used in an increasing number of studies in dental tissue engineering. Those cells show mesenchymal (stromal) stem cell-like properties including self-renewal and multilineage differentiation potentials, aside from...... an updated review on dental pulp stem cells and their applications in periodontal regeneration, in combination with different scaffolds and growth factors.......Inflammatory periodontal disease is a major cause of loss of tooth-supporting structures. Novel approaches for regeneration of periodontal apparatus is an area of intensive research. Periodontal tissue engineering implies the use of appropriate regenerative cells, delivered through a suitable...

  14. Feline dental disease.

    Science.gov (United States)

    Frost, P; Williams, C A

    1986-09-01

    Periodontal disease and chronic gingivitis/stomatitis are the most common feline dental diseases. With routine dental care and increased emphasis on home oral hygiene, these diseases can be controlled. Cats can be seen with a number of other dental disorders, and improved treatment methods such as restorations of early subgingival resorptive lesions, endodontic therapy, and orthodontic therapy can be performed successfully. More study and research are necessary about the gingivitis/stomatitis syndrome and subgingival resorptive lesions so that improved prevention and treatment recommendations can be made.

  15. Optimization MRR Of Stainless Steel 403 In Abrasive Water Jet Machining UsingAnova And Taguchi Method

    Directory of Open Access Journals (Sweden)

    Ramprasad,

    2015-05-01

    Full Text Available Stainlesssteel 403 is high-alloysteelwith good corrosion resistance and it’svery hard material. Abrasive water jet is an effective method for machining, cutting and drilling of stainlesssteel 403. In thispaperweoptimize the metalremoval rate of stainlesssteel 403 in abrasive water jet machining. The MRRisoptimize by usingthreeparameters water pressure, abrasive flow rate and stand-off distance and L9 orthogonal array of Taguchimethod use to analyse the result. 9 experimentalrunsbased on L9 orthogonal array of Taguchimethod.

  16. Análise quantitativa da remoção de esmalte dental durante a técnica de microabrasão

    OpenAIRE

    Ramalho, Karen Muller; Aranha, Ana Ceclilia Correa; Eduardo, Carlos de Paula; Rocha, Rodney Garcia; Bello-Silva, Marina Stella; Lampert, Friedrich; Esteves-Oliveira, Marcella

    2014-01-01

    Objective: To quantify, by means of profi lometry, the removal of dental enamel during the use of a microabrasion technique involving the use of hydrochloric acid and manual abrasion with a plastic spatula. Method: Thirty six specimens obtained from human third molars were polished to obtain fl at surfaces and divided into 3 groups (n = 12) according to the different treatments received: A placebo treatment with deionized water as a negative control (CG); microabrasion with 6.6% hydrochloric ...

  17. Long Term Fatigue Behavior of Zirconia Based Dental Ceramics

    Directory of Open Access Journals (Sweden)

    Moustafa N. Aboushelib

    2010-04-01

    Full Text Available This study evaluated the influence of cyclic loading on zirconia bar-shaped specimens after being subjected to three different surface treatments: particle abrasion with either 50 μm or 110 μm alumina and grinding with diamond points, while polished specimens served as a control. Statistical analysis revealed significant reduction (38-67% in flexure strength (P < 0.001 after three million cycles of dynamic loading for all surface treatments. Scanning electron imaging revealed grain boundary thickening, grain pull-out, and micro-cracking as the main structural defects. The results suggest that various surface treatments of zirconia based dental ceramics may significantly influence their long term fatigue resistance in the oral environment.

  18. Statistical Analysis for Subjective and Objective Evaluations of Dental Drill Sounds.

    Directory of Open Access Journals (Sweden)

    Tomomi Yamada

    Full Text Available The sound produced by a dental air turbine handpiece (dental drill can markedly influence the sound environment in a dental clinic. Indeed, many patients report that the sound of a dental drill elicits an unpleasant feeling. Although several manufacturers have attempted to reduce the sound pressure levels produced by dental drills during idling based on ISO 14457, the sound emitted by such drills under active drilling conditions may negatively influence the dental clinic sound environment. The physical metrics related to the unpleasant impressions associated with dental drill sounds have not been determined. In the present study, psychological measurements of dental drill sounds were conducted with the aim of facilitating improvement of the sound environment at dental clinics. Specifically, we examined the impressions elicited by the sounds of 12 types of dental drills in idling and drilling conditions using a semantic differential. The analysis revealed that the impressions of dental drill sounds varied considerably between idling and drilling conditions and among the examined drills. This finding suggests that measuring the sound of a dental drill in idling conditions alone may be insufficient for evaluating the effects of the sound. We related the results of the psychological evaluations to those of measurements of the physical metrics of equivalent continuous A-weighted sound pressure levels (LAeq and sharpness. Factor analysis indicated that impressions of the dental drill sounds consisted of two factors: "metallic and unpleasant" and "powerful". LAeq had a strong relationship with "powerful impression", calculated sharpness was positively related to "metallic impression", and "unpleasant impression" was predicted by the combination of both LAeq and calculated sharpness. The present analyses indicate that, in addition to a reduction in sound pressure level, refining the frequency components of dental drill sounds is important for creating a

  19. Xilitol and dental caries.

    NARCIS (Netherlands)

    Smits, Marten Titus

    1987-01-01

    Dental caries is a widespread multifactoral disease. The main sympthons are minaral loss from tooth enemal and dentine, eventually leading to total destruction of the teeth, pain, impairment of mastication and problems with facial esthetics. ... Zie: Summary

  20. Dental Treatment Considerations

    Science.gov (United States)

    ... ask about Dental Treatment Considerations www.myasthenia.org Myasthenia gravis (MG) is an autoimmune neuromuscular disorder that presents ... diagnosis and optimal care of individuals affected by myasthenia gravis and closely related disorders and to improve their ...

  1. Dental Care in Scleroderma

    Science.gov (United States)

    ... a side effect • Avoid the spiral of depression – depression causes worse oral health and poor oral health worsens depression. Suggestions for your dental appointments: • Tell the dentist ...

  2. Computational Fluid Dynamic Simulation of Flow in Abrasive Water Jet Machining

    Science.gov (United States)

    Venugopal, S.; Sathish, S.; Jothi Prakash, V. M.; Gopalakrishnan, T.

    2017-03-01

    Abrasive water jet cutting is one of the most recently developed non-traditional manufacturing technologies. In this machining, the abrasives are mixed with suspended liquid to form semi liquid mixture. The general nature of flow through the machining, results in fleeting wear of the nozzle which decrease the cutting performance. The inlet pressure of the abrasive water suspension has main effect on the major destruction characteristics of the inner surface of the nozzle. The aim of the project is to analyze the effect of inlet pressure on wall shear and exit kinetic energy. The analysis could be carried out by changing the taper angle of the nozzle, so as to obtain optimized process parameters for minimum nozzle wear. The two phase flow analysis would be carried by using computational fluid dynamics tool CFX. It is also used to analyze the flow characteristics of abrasive water jet machining on the inner surface of the nozzle. The availability of optimized process parameters of abrasive water jet machining (AWJM) is limited to water and experimental test can be cost prohibitive. In this case, Computational fluid dynamics analysis would provide better results.

  3. Comparative evaluation of enamel abrasivity by toothbrush and velcro: An in vitro scanning electron microscope study

    Directory of Open Access Journals (Sweden)

    Saroj Kumar Ojha

    2015-01-01

    Full Text Available Context: Plaque control has been shown to be pivotal in maintaining the optimal periodontal health. Mechanical plaque control is the most popular option for establishing the optimal oral health. Toothbrushes have been the novel tool for mechanical cleansing. However, the abrasive potential of the toothbrushes on the enamel surface is an area in gray. Aims: The aim of this in vitro study is to evaluate the abrasivity of the toothbrush versus the velcro fasteners. Settings and Design: Forty extracted clinically healthy premolars were grouped in two groups. Group A comprising of teeth that were subjected to toothbrush bristles and group B to velcro fasteners (hook and loop. Materials and Methods: The mounted teeth of both the groups were subjected to abrasion test, and the tooth surfaces were observed for the possible abrasions from the oscillating strokes (toothbrush and frictional contacts (hook and loop velcro and examined under the scanning electron microscope. Results: Comparative assessment of both velcro (hook and loop and toothbrush bristles did not reveal any evidence of abrasion on the tooth specimens. Conclusions: Veclro fasteners are safe and qualitatively at par to the manual toothbrush for their efficacy and efficiency in teeth cleansing

  4. Effect of carbonitride precipitates on the abrasive wear behaviour of hardfacing alloy

    Science.gov (United States)

    Yang, Ke; Yu, Shengfu; Li, Yingbin; Li, Chenglin

    2008-06-01

    Hardfacing alloy of martensitic stainless steel expect higher abradability to be achieved through the addition of nitrogen being provided by the fine scale precipitation of complex carbonitride particles. Niobium and titanium as the most effective carbonitride alloying elements were added in the Fe-Cr13-Mn-N hardfacing alloy to get carbonitride precipitates. Carbonitride was systematically studied by optical microscopy, scanning electronic microscopy and energy spectrum analysis. Abrasive wear resistance of hardfacing alloy in as-welded and heat-treated conditions was tested by using the belt abrasion test apparatus where the samples slide against the abrasive belt. It is found that carbonitride particles in the hardfacing alloy are complex of Cr, Ti and Nb distributing on the grain boundary or matrix of the hardfacing alloy with different number and size in as-welded and heat-treated conditions. A large number of carbonitrides can be precipitated with very fine size (nanoscale) after heat treatment. As a result, the homogeneous distribution of very fine carbonitride particles can significantly improve the grain-abrasion wear-resisting property of the hardfacing alloy, and the mass loss is plastic deformation with minimum depth of grooving by abrasive particles and fine delamination.

  5. Abrasive Performance of Chromium Carbide Reinforced Ni3Al Matrix Composite Cladding

    Institute of Scientific and Technical Information of China (English)

    LI Shang-ping; LUO He-li; FENG Di; CAO Xu; ZHANG Xi-e

    2009-01-01

    The Microstructure and room temperature abrasive wear resistance of chromium carbide reinforced NiM3Al matrix composite cladding at different depth on nickel base alloy were investigated. The results showed that there is a great difference in microstructure and wear resistance of the Ni3 Al matrix composite at different depth. Three kinds of tests, designed for different load and abrasive size, were used to understand the wear behaviour of this material. Under all three wear conditions, the abrasion resistance of the composite cladding at the depth of 6 mm, namely NC-M2, was much higher than that of the composite cladding at the depth of 2 mm, namely NC-M1. In addition, the wear-resistant advantage of NC-M2 was more obvious when the size of the abrasive was small. The relative wear resistance of NC-M2 increased from 1.63 times to 2.05 times when the size of the abrasive decreased from 180 μm to 50μm. The mierostructure of the composite cladding showed that the size of chromium carbide particles, which was mainly influenced by cooling rate of melting pool, was a function of distance from the interface between the coating and substrate varied gradually. The chromium carbide particles near the interface were finer than that far from inter-face, which was the main reason for the different wear resistance of the composite cladding at different depth.

  6. Projectile Nose Mass Abrasion of High-Speed Penetration into Concrete

    Directory of Open Access Journals (Sweden)

    Haijun Wu

    2012-01-01

    Full Text Available Based on the dynamic spherical cavity expansion theory of concrete and the analysis of experimental data, a mass abrasion model of projectile considering the hardness of aggregates, the relative strength of target and projectile, and the initial impact velocity is constructed in this paper. Furthermore, the effect of mass abrasion on the penetration depth of projectile and the influence of hardness of aggregates and strength of projectile on penetration depth and mass loss are also analyzed. The results show that, for the ogive-nose projectile with the CRH of 3 and aspect ratio of 7 penetrating the concrete of 35 MPa, the “rigid-body penetration” model is available when the initial impact velocity is lower than 800 m/s. However, when the initial impact velocity is higher than 800 m/s, the “deforming/eroding body penetration” model should be adopted. Through theoretical analysis and numerical calculation, the results indicate that the initial impact velocity is the most important factor of mass abrasion. The hardness of aggregates and the strength of projectile are also significant factors. But relatively speaking, the sensitivity of strength of projectile to mass abrasion is higher, which indicates that the effect of projectile material on mass abrasion is more dramatic than the hardness of aggregates.

  7. The effect of heat treatment on the gouging abrasion resistance of alloy white cast irons

    Science.gov (United States)

    Are, I. R. S.; Arnold, B. K.

    1995-02-01

    A series of heat treatments was employed to vary the microstructure of four commercially important alloy white cast irons, the wear resistance of which was then assessed by the ASTM jaw-crusher gouging abrasion test. Compared with the as-cast condition, standard austenitizing treatments produced a substantial increase in hardness, a marked decrease in the retained aus-tenite content in the matrix, and, in general, a significant improvement in gouging abrasion resistance. The gouging abrasion resistance tended to decline with increasing austenitizing tem-perature, although the changes in hardness and retained austenite content varied, depending on alloy composition. Subcritical heat treatment at 500 ° following hardening reduced the retained austenite content to values less than 10 pct, and in three of the alloys it caused a significant fall in both hardness and gouging abrasion resistance. The net result of the heat treatments was the development of optimal gouging abrasion resistance at intermediate levels of retained aus-tenite. The differing responses of the alloys to both high-temperature austenitizing treatments and to subcritical heat treatments at 500 ° were related to the effects of the differing carbon and alloying-element concentrations on changes in the M s temperature and secondary carbide precipitation.

  8. Abrasion of human enamel by brushing with a commercial dentifrice containing hydroxyapatite crystals in vitro.

    Science.gov (United States)

    Kodaka, T; Kobori, M; Hirayama, A; Abe, M

    1999-01-01

    Automatic toothbrushing with a commercial dentifrice containing hydroxyapatite (HAP) crystals was performed on the tangential polished surfaces of sound human enamel, mainly consisting of biological apatite similar to HAP, for 10 min in vitro. The X-ray diffraction peaks of HAP, brushite (DCPD), and monetite (DCP) crystals were detected from the dentifrice. After brushing, the enamel surfaces were observed with a scanning electron and a confocal scanning laser microscope. The brushing caused larger abrasive loss and more remarkable roughness of the enamel surfaces following the broad traces of brush bristles and the exposure of prism structures than brushing with a dentifrice containing only DCPD, which we previously reported. We claim that the fine granular-shaped HAP crystals of the dentifrice indicated as an active ingredient for preventing enamel caries possess stronger abrasivity of sound enamel than the DCPD and DCP as abrasives on account of their Mohs hardness values rather than sizes and shapes. The HAP crystals of dentifrices may not occlude the small defects of early caries enamel, but erode them more strongly as an abrasive than the other abrasives.

  9. Finishing of display glass for mobile electronics using 3M Trizact diamond tile abrasive pads

    Science.gov (United States)

    Zheng, Lianbin; Fletcher, Tim; Na, Tee Koon; Sventek, Bruce; Romero, Vince; Lugg, Paul S.; Kim, Don

    2010-10-01

    This paper will describe a new method being used during the finishing of glass displays for mobile electronics including mobile hand held devices and notebook computers. The new method consists of using 3M TrizactTM Diamond Tile Abrasive Pads. TrizactTM Diamond Tile is a structured fixed abrasive grinding technology developed by 3M Company. The TrizactTM Diamond Tile structured abrasive pad consists of an organic (polymeric binder) - inorganic (abrasive mineral, i.e., diamond) composite that is used with a water-based coolant. TrizactTM Diamond Tile technology can be applied in both double and single side grinding applications. A unique advantage of TrizactTM Diamond Tile technology is the combination of high stock removal and low sub-surface damage. Grinding results will be presented for both 9 micron and 20 micron grades of TrizactTM Diamond Tile abrasive pads used to finish several common display glasses including Corning GorillaTM glass and Soda Lime glass.

  10. Abrasive wear characteristics and mechanisms of Al2O3/PA1010 composite coatings

    Institute of Scientific and Technical Information of China (English)

    JIA Xian; LING Xiaomei

    2004-01-01

    The abrasive wear characteristics of Al2O3/PA1010 composite coatings on the surface of quenched and low-temperature temper steel 45 were tested on the mmplate abrasive wear testing machine and the same uncoated steel 45 was used as a reference material. Experimental results showed that the abrasive wear resistance of Al2O3//PAl010 composite coatings has a good linear relationship with the volume fraction of Al2O3 particles in Al2O3/PAl010 composite coatings, and the linear correlative coefficient is 0.979. Under the experimental conditions, the size of Al2O3 particles (40.5-161.0 μm) has little influence on the abrasive wear resistance of Al2O3/PA l010 composite coatings. By treating the surface of Al2O3 particles with a suitable bonding agent, the distribution of Al2O3 particles in matrix PAl010 is more homogeneous and the bonding state between Al2O3 particles and matrix PAl010 is better. Therefore, the ml2O3 particles in Al2O3/PA1010 composite coatings make the Al2O3/PAl010 composite coatings have better abrasive wear resistance than PA1010 coatings. The wear resistance of Al2O3/PA 1010 composite coatings is about 45% compared with that of steel 45.

  11. Dental patients' use of the Internet.

    LENUS (Irish Health Repository)

    2009-12-19

    To determine the use of the Internet by patients attending a range of dental clinics to search for information regarding dental procedures, and also to investigate their interest in online dental consultations and \\'dental tourism\\'.

  12. Computational Fluid Dynamics Analysis of Nozzle in Abrasive Water Jet Machining

    Science.gov (United States)

    Venugopal, S.; Chandresekaran, M.; Muthuraman, V.; Sathish, S.

    2017-03-01

    Abrasive water jet cutting is one of the most recently developed non-traditional manufacturing technologies. The general nature of flow through the machining, results in rapid wear of the nozzle which decrease the cutting performance. It is well known that the inlet pressure of the abrasive water suspension has main effect on the erosion characteristics of the inner surface of the nozzle. The objective of the project is to analyze the effect of inlet pressure on wall shear and exit kinetic energy. The analysis would be carried out by varying the inlet pressure of the nozzle, so as to obtain optimized process parameters for minimum nozzle wear. The two phase flow analysis would be carried by using computational fluid dynamics tool CFX. The availability of minimized process parameters such as of abrasive water jet machining (AWJM) is limited to water and experimental test can be cost prohibitive.

  13. Structural transformations in wear resistance of iron- and cobalt-based amorphous alloys during abrasive wear

    Science.gov (United States)

    Korshunov, L. G.; Shabashov, V. A.; Chernenko, N. L.

    2010-04-01

    The wear resistance and structural changes in a number of amorphous alloys based on iron and cobalt and in high-carbon tool steels are studied during wear by a fixed abrasive (crondum, Carborundum) at room temperature and -196°C. The abrasive wear resistance of the amorphous alloys is shown to be 1.6-3.1 lower than that of the high-carbon tool steels having a similar hardness. The relatively low level of the abrasive wear resistance of the amorphous alloys is assumed to be caused by strain softening of their surface during wear. A nanocrystalline structure is found to form in local microvolumes in a thin deformed surface layer of the alloys.

  14. Evaluation of subsurface damage in GaN substrate induced by mechanical polishing with diamond abrasives

    Energy Technology Data Exchange (ETDEWEB)

    Aida, Hideo, E-mail: h-aida@namiki.net [NJC Institute of Technology, Namiki Precision Jewel Co., Ltd., 3-8-22 Shinden, Adachi, Tokyo 123-8511 (Japan); KASTEC, Kyushu University, Kasuga-shi, Fukuoka 816-8580 (Japan); Takeda, Hidetoshi; Kim, Seong-Woo; Aota, Natsuko; Koyama, Koji [NJC Institute of Technology, Namiki Precision Jewel Co., Ltd., 3-8-22 Shinden, Adachi, Tokyo 123-8511 (Japan); Yamazaki, Tsutomu; Doi, Toshiro [KASTEC, Kyushu University, Kasuga-shi, Fukuoka 816-8580 (Japan)

    2014-02-15

    The relationship between the depth of the subsurface damage (SSD) and the size of the diamond abrasive used for mechanical polishing (MP) of GaN substrates was investigated in detail. GaN is categorized as a hard, brittle material, and material removal in MP proceeds principally to the fracture of GaN crystals. Atomic force microscopy and cathodoluminescence imaging revealed that the mechanical processing generated surface scratches and SSD. The SSD depth reduced as the diamond abrasive size reduced. A comparison of the relationship between the SSD depth and the diamond abrasive size used in the MP of GaN with the same relationship for typical brittle materials such as glass substrates suggests that the MP of GaN substrates proceeds via the same mechanism as glass.

  15. The rock abrasion record at Gale Crater: Mars Science Laboratory results from Bradbury Landing to Rocknest

    Science.gov (United States)

    Bridges, N.T.; Calef, F.J.; Hallett, B.W.; Herkenhoff, Kenneth E.; Lanza, N.L.; Le Mouélic, S.; Newman, C.E.; Blaney, D.L.; de Pablo, M.A.; Kocurek, G.A.; Langevin, Y.; Lewis, K.W.; Mangold, N.; Maurice, S.; Meslin, P.-Y.; Pinet, P.; Renno, N.O.; Rice, CM.S.; Richardson, M.E.; Sautter, V.; Sletten, R.S.; Wiens, R.C.; Yingst, R.A.

    2014-01-01

    Ventifacts, rocks abraded by wind-borne particles, are found in Gale Crater, Mars. In the eastward drive from “Bradbury Landing” to “Rocknest,” they account for about half of the float and outcrop seen by Curiosity's cameras. Many are faceted and exhibit abrasion textures found at a range of scales, from submillimeter lineations to centimeter-scale facets, scallops, flutes, and grooves. The drive path geometry in the first 100 sols of the mission emphasized the identification of abrasion facets and textures formed by westerly flow. This upwind direction is inconsistent with predictions based on models and the orientation of regional dunes, suggesting that these ventifact features formed from very rare high-speed winds. The absence of active sand and evidence for deflation in the area indicates that most of the ventifacts are fossil features experiencing little abrasion today.

  16. An Investigation on a Tin Fixed Abrasive Polishing Pad with Phyllotactic Pattern for Polishing Wafer

    Institute of Scientific and Technical Information of China (English)

    吕玉山; 刘电飞; 寇智慧

    2012-01-01

    In order to improve the polishing ability of polishing pads, a kind of polishing pad with the tin fixed abrasive blocks, which are arranged based on the phyllotaxis theory of biology, was designed and fabricated by the use of electroplating technology, and also its polishing ability for JGS-2 wafer was investigated by polishing experiments. The research resuits show that the phyllotactic parameters of the polishing pad influence the arrangement density of the tin fixed abrasive blocks, the polishing pad with phyllotactic pattern is feasibly fabricated by the use of electroplating technology, and the good polishing result can be obtained by using the polishing pad with pbyllotactic pattern to polish a wafer when the diameter D of the tin fixed abrasive block is between Φ. 3 mm and Φ1. 4 mm, and the phyllotactic coefficient k between 1.0 and 1.1, respectively.

  17. Understanding Characteristic of Abrasion of Refractory Lining Caused by Bath Oscillation in BOF Steelmaking

    Science.gov (United States)

    Li, Qiang; Li, Mingming; Kuang, S. B.; Zou, Zongshu

    2016-12-01

    This paper presents a numerical study of the refractory abrasion occurring widely inside basic oxygen furnace (BOF) steelmaking. The mechanism of refractory abrasion is examined numerically referring to the bath oscillation with regard to flows, turbulence and wall shear stress inside a BOF. The simulation results reveal that the refractory abrasion tends to occur on the wall region between the slag/atmosphere and slag/metal interfaces due to the oscillation of the bath in the blowing process, which generally promotes slag-line erosion. The decreased nozzle angle, and either increased lance height or operation pressure can lead to more serious refractory erosion that occurs more likely during the slag-making period in the operation of BOF.

  18. A Review on Current Research and Development in Abrasive Waterjet Machining

    Directory of Open Access Journals (Sweden)

    M. M. Korat

    2014-01-01

    Full Text Available Abrasive waterjet machining (AWJM is an emerging machining technology option for hard material parts that are extremely difficult-to-machine by conventional machining processes. A narrow stream of high velocity water mixed with abrasive particles gives relatively inexpensive and environment friendly production with reasonably high material removal rate. Because of that abrasive waterjet machining has become one of the leading manufacturing technologies in a relatively short period of time. This paper reviews the research work carried out from the inception to the development of AWJM within the past decade. It reports on the AWJM research relating to improving performance measures, monitoring and control of process, optimizing the process variables. A wide range of AWJM industrial applications for different category of material are reported with variations. The paper also discusses the future trend of research work in the same area.

  19. Abrasive wear: The efects of fibres size on oil palm empty fruit bunch polyester composite

    Science.gov (United States)

    Kasolang, S.; Kalam, A.; Ahmad, M. A.; Rahman, N. A.; Suhadah, W. N.

    2012-06-01

    This paper presents an experimental investigation carried out to determine the effect of palm oil empty fruit bunch (OPEFB) fibre size in dry sliding testing of polyester composite. These composite samples were produced by mixing raw OPEFB fibre with resin. The samples were prepared at different sizes of fibre (100, 125, 180 and 250μm). Abrasion Resistance Tester (TR-600) was used to carried out abrasive wear tests in dry sliding conditions. These tests were performed at room temperature for two different loads (10 and 30N) and at a constant sliding velocity of 1.4m/s. The specific wear rates of OPEFB polyester composites were obtained. The morphology of composite surface before and after tests was also examined using 3D microscope imaging. Preliminary work on thermal distribution at the abrasive wheel point was also conducted for selected samples.

  20. Predicting Los Angeles abrasion loss of rock aggregates from crushability index

    Indian Academy of Sciences (India)

    S Kahraman; O Y Toraman

    2008-04-01

    Predicting Los Angeles abrasion loss of aggregate material from some simpler tests will be useful for especially preliminary studies. For this reason, to investigate the possibility of predicting the Los Angeles abrasion loss from the crushability index, Los Angeles abrasion, crushability, density and porosity tests were performed on 11 different rock types collected from different areas of Turkey. The results of the tests were analysed using simple and multiple regression analyses. Generally significant correlations were obtained from both simple and multiple regression analyses. The correlation coefficients and estimation capabilities of the two multiple regression equations are slightly higher than that of the simple regression equation. It was concluded that the simple regression equation is practical and reliable enough for estimation purposes. However, the two multiple regression equations can be used for a more accurate estimation.

  1. Energy Consumption in Comminution of Mica with Cavitation Abrasive Water Jet

    Institute of Scientific and Technical Information of China (English)

    GUO Chu-wen; DONG Lu

    2007-01-01

    We have studied the efficiency of energy consumption in the comminution of mica powder with cavitation abrasive water jet technology. The energy required to create new surfaces in the comminution of mica powder with cavitation abrasive water jet was calculated, in order to estimate its efficiency of energy consumption. The particle size distribution and the specific surface area were measured by applying a JEM-200CX transmission electron microscope and an Autosorb-1 automatic surface area analyzer. The study results show that the efficiency of energy consumed in creating new surface areas is as high as 2.92%, or 4.94% with the aid of cavitation in the comminution of mica powder. This efficiency will decrease with an increase in the number of comminutions. After three comminutions, the efficiencies will become 1.91% and 2.29% for comminution without cavitation and with cavitation, respectively. The abrasive water jet technology is an effective way for comminution of mica powder.

  2. Micro-scale Abrasion and Medium Load Multiple Scratch Tests of PVD Coatings.

    Institute of Scientific and Technical Information of China (English)

    S.Poulat; H.Sun; D.GTeer

    2004-01-01

    Micro-scale abrasion testing is widely used to determine the abrasion resistance of thin film coatings; it is a simple technique that can easily be used as part of a quality control procedure, but it has got the disadvantage of not allowing an easy study of the wear mechanisms involved: it is difficult to estimate the load applied on each abrasive particles in the contact between the loaded ball and the specimen. The possibility of using progressive loading scratch testing, a method widely used to assess the adhesion of thin film coatings, to model the abrasive wear of coatings has been studied in the past; the use of multiple scratch tests to study the wear mechanisms corresponding to a single abrasion scratch event has also been studied in the case of bulk materials (ceramics and hard metals). Two coatings, deposited by Closed Field Unbalanced Magnetron Sputter Ion Plating (CFUBMSIP) on ASP23 powder metallurgy steel substrate are chosen to be representative of the use of protective coatings in industry: titanium nitride, which is widely used to prevent tool wear, and TCL Graphit-iCTM, which is widely used as a wear resistant solid lubricant coating. The two coatings are first characterised by using a standard quality control procedure: their thickness is determined by the cap grinding method, their adhesion by progressive loading scratch. Then micro-scale abrasion tests performed with a slurry at a concentration which promotes grooving wear, and medium load multiple scratch tests performed with diamond indenters are completed; the results of these tests are analysed and compared to determine if there is any correlation between the two sets of results; the multiple scratch tests wear tracks are also observed to determine the wear mechanisms involved.

  3. Abrasion Testing of Candidate Outer Layer Fabrics for Lunar EVA Space Suits

    Science.gov (United States)

    Mitchell, Kathryn C.

    2010-01-01

    During the Apollo program, the space suit outer layer fabrics were badly abraded after just a few Extravehicular Activities (EVAs). For example, the Apollo 12 commander reported abrasive wear on the boots, which penetrated the outer layer fabric into the thermal protection layers after less than eight hours of surface operations. Current plans for the Constellation Space Suit Element require the space suits to support hundreds of hours of EVA on the Lunar surface, creating a challenge for space suit designers to utilize materials advances made over the last forty years and improve upon the space suit fabrics used in the Apollo program. A test methodology has been developed by the NASA Johnson Space Center Crew and Thermal Systems Division for establishing comparative abrasion wear characteristics between various candidate space suit outer layer fabrics. The abrasion test method incorporates a large rotary drum tumbler with rocks and loose lunar simulant material to induce abrasion in fabric test cylinder elements, representative of what might occur during long term planetary surface EVAs. Preliminary materials screening activities were conducted to determine the degree of wear on representative space suit outer layer materials and the corresponding dust permeation encountered between subsequent sub -layers of thermal protective materials when exposed to a simulated worst case eight hour EVA. The test method was used to provide a preliminary evaluation of four candidate outer layer fabrics for future planetary surface space suit applications. This Paper provides a review of previous abrasion studies on space suit fabrics, details the methodologies used for abrasion testing in this particular study, and shares the results and conclusions of the testing.

  4. History of dental hygiene research.

    Science.gov (United States)

    Bowen, Denise M

    2013-01-01

    Dental hygiene is defined as the science and practice of the recognition, treatment and prevention of oral diseases. The history of dental hygiene research is considered in the context of the development of the discipline and an emerging infrastructure. Research-related events supporting the growth and maturation of the profession are considered from the early years to the most recent. The benefits of preventive oral health services provided by dental hygienists have been supported by research, and the practice of dental hygiene has expanded as a result of research findings since its inception 100 years ago. Dental hygienists' engagement in research, however, did not begin until the 1960s as research associates or administrators, primarily with dental researchers as primary investigators. The Journal of Dental Hygiene (JDH) has provided information for dental hygiene practice since 1927, and has been the primary venue for dissemination of dental hygiene research since 1945. Graduate education in dental hygiene at the master's degree level and the work of early dental hygiene researchers led to the first conference on dental hygiene research in 1982. Over 30 years later, dental hygiene has established a meta-paradigm and defined conceptual models, built an initial infrastructure to support research endeavors and contributed much to the development of dental hygiene as a unique discipline. A doctoral degree in the discipline, continued theory-based research, initiatives to foster collaborations between dental hygiene and other researchers and enhanced capabilities to attract funding to support large scale studies are goals that must be attained through the efforts of future researchers to address the needs for additional development in the discipline of dental hygiene. Dental hygiene research supports the growing discipline and its value to society.

  5. High Speed Lapping of SiC Ceramic Material with Solid (Fixed) Abrasives

    Institute of Scientific and Technical Information of China (English)

    ZHANG Wei; YANG Xin-hong; SHANG Chun-min; HU Xiao-yong; HU Zhong-hui

    2005-01-01

    An experimental investigation is carried out to machine SiC ceramic material through the method of high speed plane lapping with solid(fixed) abrasives after the critical condition of brittle-ductile transition is theoretically analyzed. The results show that the material removal mechanism and the surface roughness are chiefly related to the granularity of abrasives for brittle materials such as SiC ceramic. It is easily realized to machine SiC ceramic in the ductile mode using W3.5 grit and a high efficiency, low cost and smooth surface with a surface roughness of Ra 2.4nm can be achieved.

  6. Methods for atomistic abrasion simulations of laterally periodic polycrystalline substrates with fractal surfaces

    Science.gov (United States)

    Eder, S. J.; Bianchi, D.; Cihak-Bayr, U.; Gkagkas, K.

    2017-03-01

    In this work we discuss a method to generate laterally periodic polycrystalline samples with fractal surfaces for use in molecular dynamics simulations of abrasion. We also describe a workflow that allows us to produce random lateral distributions of simple but realistically shaped hard abrasive particles with Gaussian size distribution and random particle orientations. We evaluate some on-the-fly analysis and visualization possibilities that may be applied during a molecular dynamics simulation to considerably reduce the post-processing effort. Finally, we elaborate on a parallelizable post-processing approach to evaluating and visualizing the surface topography, the grain structure and orientation, as well as the temperature distribution in large atomistic systems.

  7. ANN & ANFIS Models for Prediction of Abrasive Wear of 3105 Aluminium Alloy with Polyurethane Coating

    Directory of Open Access Journals (Sweden)

    H. Alimam

    2016-06-01

    Full Text Available The quest for safety and reliability has increased significantly after Industrial revolution, so is the case for coating industries. In this paper 3105 Aluminium alloy sheet is coated with organic polyurethane coating. After the implementation of coating, various processes are undergone to check its reliability under elevated conditions. ANN & ANFIS model were developed and trained with an objective to find abrasive wear during the process. ANN & ANFIS model were compared with the experimental results. It is observed that the abrasive wear of a coated specimen can be predicted accurately and precisely using ANN and ANFIS models.

  8. Abrasive Wear Behavior of High Chromium Cast Iron and Hadfield Steel-- A Comparison

    Institute of Scientific and Technical Information of China (English)

    Mehdi Mazar Atabaki; Sajjad Jafari; Hassan Abdollah-pour

    2012-01-01

    Wear properties of two different crushers used for grinding raw materials of cement industry are compared using pin-on-disk wear test.The wear test was carried out with different loads on a pin.Abrasive wear behavior of two alloys was evaluated by comparing mass loss,wear resistance,microhardness and friction coefficient.The microstructure of the specimens was detected using optical microscope.The results showed that abrasive wear of high chromium cast iron is lower than that of Hadfield steel.Due to the presence of M7C3 carbides on the high chromium cast iron matrix,impact crushers exhibited higher friction coefficient

  9. Water jet and abrasive water jet cutting of unidirectional graphite/epoxy composite

    Science.gov (United States)

    Ramulu, M.; Arola, D.

    1993-06-01

    Unidirectional graphite/epoxy composite material has been machined by water jet and abrasive water jet cutting processes. Topography and morphology of the machined surfaces were evaluated with surface profilometry and scanning electron microscopy. The surface characteristics in terms of roughness and the micromechanisms of material removal for both processes were analyzed and compared. Abrasive water jet surface characteristics of graphite/epoxy were found to be significantly different from those of the water jet cutting process and micromechanical behavior of material removal was strongly dependent on the fiber orientation.

  10. Development and validation of an alternative disturbed skin model by mechanical abrasion to study drug penetration

    Directory of Open Access Journals (Sweden)

    P. Schlupp

    2014-01-01

    Skin permeation of the three substances was increased in tape-stripped and abraded skin compared to untreated skin due to the reduced barrier integrity. Enhancement of drug uptake was highest for the most hydrophilic substance, caffeine, followed by sorbic acid and lipophilic testosterone. No significant difference in drug uptake studies was observed between the new abrasion method with an aluminum-coated sponge and the tape-stripping method. The obtained results demonstrate that this abrasion method is an alternative way to achieve a disturbed skin barrier for drug and chemical uptake studies.

  11. Abrasion Resistance of as-Cast High-Chromium Cast Iron

    Directory of Open Access Journals (Sweden)

    Pokusová Marcela

    2014-12-01

    Full Text Available High chromium cast irons are widely used as abrasion resistant materials. Their properties and wear resistance depend on carbides and on the nature of the matrix supporting these carbides. The paper presents test results of irons which contain (in wt.% 18-22 Cr and 2-5 C, and is alloyed by 1.7 Mo + 5 Ni + 2 Mn to improve the toughness. Tests showed as-cast irons with mostly austenitic matrix achieved hardness 36-53 HRC but their relative abrasion-resistance was higher than the tool steel STN 19436 heat treated on hardness 60 HRC.

  12. DENTAL HOT-COLD SENSITIVITY AND TRAUMATIC DENTAL INJURIES

    OpenAIRE

    Traebert, Jefferson; Martins,Luiz Gustavo Teixeira; Traebert, Eliane Silva de Azevedo; Bortoluzzi, Marcelo Carlos

    2014-01-01

    AIM: Although several studies have indicated negative impacts of traumatic dental injuries on children’s quality of life, virtually none of them have explored the possible association between them and the occurrence and dental hot-cold sensitivity. The aim of this study was to study the possible association of hot-cold dental sensitivity and history of traumatic dental injuries. MATERIAL AND METHODS: A cross-sectional study involving a representative sample of 11- to 14-year-old schoolchildre...

  13. Clinical comparison between dental high speed air turbine cutting handpiece and traditional instruments in mandibular impacted teeth extraction%牙科高速气涡轮切割手机与传统器械拔除下颌阻生第三磨牙的临床比较

    Institute of Scientific and Technical Information of China (English)

    王莹莹; 程继光; 陈新; 徐文华; 周健

    2015-01-01

    Objective To evaluate the effect of mandibular impacted teeth extraction with dental high speed air turbine cutting hand-piece and surgery bur.Methods This study included 120 patients from Anhui Stomatology Hospital whose third molar teeth were ex-tracted.These patients were randomly assigned into two groups:the experimental group and control group.The control group was treated using tradition chisel splint method,meanwhile the experimental group was treated by dental high speed air turbine cutting handpiece and the bur.The probability of dental root fracture and lower lip numbness,swelling,pain and hardship of opening mouth in the consul-tation after the surgery were evaluated.Results The comparison of the probability of dental root fracture and lower lip numbness,swell-ing,pain and hardship of opening mouth between two groups was made.There were significant differences in two methods.Conclusions Dental high speed air turbine cutting handpiece and surgery bur perform better in mandibular impacted teeth extraction,which is wor-thy to be promoted and studied in clinic treatment.%目的:探讨牙科高速气涡轮切割手机配合阻生牙专用加长裂钻拔除下颌阻生牙的方法和效果。方法选择2013年5月—2014年3月期间于安徽省口腔医院口腔颌面外科门诊需要拔除下颌阻生第三磨牙患者共120例,随机分为两组,对照组采用传统劈骨分牙法,试验组采用牙科高速气涡轮切割手机配合阻生牙专用加长裂钻拔牙,通过术后复诊,评价术后肿胀、疼痛、张口受限等情况以及断根、下唇麻木等发生率。结果对对照组和试验组术后创口肿胀、疼痛、张口受限等情况进行比较,差异具有统计学意义。结论应用牙科高速气涡轮切割手机配合阻生牙专用加长裂钻拔除下颌第三阻生牙的效果较为理想,值得临床进一步研究和推广。

  14. Preparation of composite abrasives by electrostatic self-assembly method and its polishing properties in Cu CMP

    Institute of Scientific and Technical Information of China (English)

    Huang Yishen; Xu Xuefeng; Yao Chunyan; Hu Jiande; Peng Wei

    2014-01-01

    The adsorption characteristics of cationic polyelectrolyte poly dimethyl diallyl ammonium chloride (PDADMAC) and anionic polyelectrolyte poly (sodium-p-styrenesulfonate) (PSS) on benzoguanamine formal-dehyde (BGF) particles are investigated. The charging characteristics of BGF particles are changed and con-trolled using electrostatic self-assembly method. A variety of PEi-BGF/SiO2 composite abrasives are obtained. The as-prepared samples are analyzed by zeta potential analysis,transmission electron microscope (TEM) and thermogravimetric (TG) analysis. The composite abrasive slurries are prepared for copper polishing. The poli-shing results indicate that it is SiO2 abrasives,not only coated SiO2 abrasive on polymer particles but also free SiO2 abrasive in slurry ,that offer the polishing action. The material removal rates of copper polishing are 264 nm/min,348 nm/min and 476 nm/min using single SiO2 abrasive slurry,PE0-BGF/SiO2 mixed abrasive slur-ry and PE3-BGF/SiO2 composite abrasive slurry,respectively. The surface roughness Ra of copper wafer (with 5μm× 5μm district) is decreased from 0.166μm to 3.7 nm,2.6 nm and 1.5 nm,and the surface peak-valley values Rpv are less than 20 nm,14 nm and 10 nm using these kinds of slurries,respectively.

  15. Synergetic effect of organic cores and inorganic shells for core/shell structured composite abrasives for chemical mechanical planarization

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Yang, E-mail: cy.jpu@126.com [School of Materials Science and Engineering, Changzhou University, Changzhou, Jiangsu 213164 (China); Li, Zhina [School of Materials Science and Engineering, Changzhou University, Changzhou, Jiangsu 213164 (China); Miao, Naiming [School of Mechanical Engineering, Changzhou University, Changzhou, Jiangsu 213016 (China)

    2014-09-30

    Highlights: • The damage-free polishing mechanism of core/shell composite abrasive was explored. • The organic core is help to decrease surface roughness and mechanical damages. • The inorganic shell is in favor of improving material removal rate. • The enhanced CMP behavior is due to the synergistic effect between core and shell. - Abstract: Core/shell structured organic/inorganic composite microspheres has an important potential application in efficient and damage-free chemical mechanical planarization/polishing (CMP) as a kind of novel abrasive due to its uniform non-rigid mechanical property. However, the synergistic effect of material removal between organic cores and inorganic shells of composite abrasives is ambiguous. In this work, oxide-CMP performances of various slurries, containing polystyrene (PS) spheres, solid abrasives (SiO{sub 2} or CeO{sub 2}), mixed abrasives ((PS + SiO{sub 2}) or (PS + CeO{sub 2})), core/shell composites (PS/SiO{sub 2} or PS/CeO{sub 2}), were investigated by atomic force microscopy. Experiment results indicated that the surfaces polished by composite abrasives exhibited lower surface roughness, fewer scratches as well as lower topographical variations than those by other type of abrasives. The core/shell structure of composite abrasives plays an important role in improving CMP behavior. Moreover, the organic cores are mainly beneficial to decrease surface roughness and mechanical damages, and the inorganic shells are in favor of improving material removal rate.

  16. Impact of Abrasion on Mass Loss and Surface Appearance of Woven Fabrics Made with Injected Slub Yarn in Weft

    Science.gov (United States)

    Ray, Nemai Chandra; Mukhopadhyay, Arunangshu; Midha, Vinay Kumar

    2016-10-01

    Fancy yarn fabrics are susceptible to abrasive damage during washing and usage but the extent of damage varies with construction and type of fabric. In the present study, effect of different slub parameters viz. slub length, slub thickness and slub frequency of single base injected slub yarn on abrasive damage of woven fabrics has been studied when injected slub yarns are used in weft only. Abrasive damage has been assessed by two ways using loss in fabric mass and deterioration in fabric appearance due to abrasion. These two techniques provide entirely different effect of injected slub yarn parameters on abrasive damage of woven fabric. Fabric abrasion damage in terms of mass loss is not affected by slub thickness and damage is least when both slub length and slub frequency are at central/medium level. Under visual assessment it is observed that all the slub parameters have significant influence on abrasive damage of woven fabric. It is possible to have lower damage in surface appearance in spite of higher mass loss of fabric due to abrasion.

  17. NK cells are necessary for recovery of corneal CD11c+ dendritic cells after epithelial abrasion injury

    Science.gov (United States)

    Mechanisms controlling CD11c(+) MHCII(+) DCs during corneal epithelial wound healing were investigated in a murine model of corneal abrasion. Selective depletion of NKp46(+) CD3- NK cells that normally migrate into the cornea after epithelial abrasion resulted in >85% reduction of the epithelial CD1...

  18. Bulimia and Anorexia Nervosa in Dental and Dental Hygiene Curricula.

    Science.gov (United States)

    Gross, Karen B. W.; And Others

    1990-01-01

    Dentists and dental hygienists are in a unique position to identify an eating disorder patient from observed oral manifestations and to refer the patient for psychological therapy. The inclusion of information on general and oral complications of bulimia and anorexia nervosa in dental and dental hygiene curriculum was examined. (MLW)

  19. An Investigation into the Relationship between Owner Knowledge, Diet, and Dental Disease in Guinea Pigs (Cavia porcellus).

    Science.gov (United States)

    Norman, Rosemary; Wills, Alison P

    2016-11-14

    Recent studies have highlighted a high prevalence of dental disease in domestic guinea pigs, yet the aetiology of this multi-factorial disease is still unclear. Factors that have been associated with dental disease include feeding a diet that is high in energy but low in fibre, feeding an insufficiently abrasive diet, a lack of dietary calcium, and genetics. As many of these factors relate to the husbandry requirements of guinea pigs, owner awareness of dietary requirements is of the utmost importance. An online questionnaire was created based on previous research into the husbandry and feeding of rabbits. Guinea pig owners were asked to answer questions on the clinical history of their animals and their diet and management. In total, 150 surveys were completed for 344 guinea pigs, where owners of multiple animals could complete the survey for individuals. According to the owners, 6.7% of guinea pigs had been clinically diagnosed with dental disease, but 16.6% had signs consistent with dental disease. The specific clinical signs of having difficulty eating (Exp(B) = 33.927, Nagelkerke R ² = 0.301, p guinea pig diet, and dental disease in the study population. This study highlights the importance of access to the outdoors for the health and welfare of guinea pigs in addition to the need for owners to be alert to key clinical signs. A relationship between diet and dental disease was not identified in this study; however, the underlying aetiological causes of this condition require further investigation.

  20. Blood Thinners and Dental Care

    Science.gov (United States)

    ... a Doctor Patient Condition Information Publications & News OOOO Journal Newsroom Clinicians’ Guides Clinical Practice Statements Newsletters Latest ... Meeting Orlando, FL Our Partners Blood Thinners and Dental Care Many dental patients are taking “blood thinner” ...

  1. Dental modification in the past

    DEFF Research Database (Denmark)

    Bennike, Pia; Alexandersen, Verner

    2003-01-01

    Skeleton remains from Denmark, Greenland, Faeroe Islands, dental care, drillling in the past, tooth extraction......Skeleton remains from Denmark, Greenland, Faeroe Islands, dental care, drillling in the past, tooth extraction...

  2. 77 FR 4469 - Dental Conditions

    Science.gov (United States)

    2012-01-30

    ... purposes. This amendment clarifies that principles governing determinations by VA's Veterans Benefits Administration (VBA) for service connection of dental conditions for the purpose of establishing eligibility for dental treatment by VA's Veterans Health Administration (VHA), apply only when VHA requests...

  3. Panoramic Dental X-Ray

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Panoramic Dental X-ray Panoramic dental x-ray uses a ... Your e-mail address: Personal message (optional): Bees: Wax: Notice: RadiologyInfo respects your privacy. Information entered here ...

  4. Dental Care - Medicaid and Chip

    Data.gov (United States)

    U.S. Department of Health & Human Services — Dental health is an important part of peoples overall health. States are required to provide dental benefits to children covered by Medicaid and the Childrens Health...

  5. Abrasive Wear Resistance of the Iron- and WC-based Hardfaced Coatings Evaluated with Scratch Test Method

    Directory of Open Access Journals (Sweden)

    A. Vencl

    2013-06-01

    Full Text Available Abrasive wear is one of the most common types of wear, which makesabrasive wear resistance very important in many industries. Thehard facing is considered as useful and economical way to improve theperformance of components submitted to severe abrasive wear conditions, with wide range of applicable filler materials. The abrasive wear resistance of the three different hardfaced coatings (two iron‐based and one WC‐based, which were intended to be used for reparation of the impact plates of the ventilation mill, was investigated and compared. Abrasive wear tests were carried‐out by using the scratch tester under the dry conditions. Three normal loads of 10, 50 and 100 N and the constant sliding speed of 4 mm/s were used. Scratch test was chosen as a relatively easy and quick test method. Wear mechanism analysis showed significant influence of the hardfaced coatings structure, which, along with hardness, has determined coatings abrasive wear resistance.

  6. New layer-based imaging and rapid prototyping techniques for computer-aided design and manufacture of custom dental restoration.

    Science.gov (United States)

    Lee, M-Y; Chang, C-C; Ku, Y C

    2008-01-01

    Fixed dental restoration by conventional methods greatly relies on the skill and experience of the dental technician. The quality and accuracy of the final product depends mostly on the technician's subjective judgment. In addition, the traditional manual operation involves many complex procedures, and is a time-consuming and labour-intensive job. Most importantly, no quantitative design and manufacturing information is preserved for future retrieval. In this paper, a new device for scanning the dental profile and reconstructing 3D digital information of a dental model based on a layer-based imaging technique, called abrasive computer tomography (ACT) was designed in-house and proposed for the design of custom dental restoration. The fixed partial dental restoration was then produced by rapid prototyping (RP) and computer numerical control (CNC) machining methods based on the ACT scanned digital information. A force feedback sculptor (FreeForm system, Sensible Technologies, Inc., Cambridge MA, USA), which comprises 3D Touch technology, was applied to modify the morphology and design of the fixed dental restoration. In addition, a comparison of conventional manual operation and digital manufacture using both RP and CNC machining technologies for fixed dental restoration production is presented. Finally, a digital custom fixed restoration manufacturing protocol integrating proposed layer-based dental profile scanning, computer-aided design, 3D force feedback feature modification and advanced fixed restoration manufacturing techniques is illustrated. The proposed method provides solid evidence that computer-aided design and manufacturing technologies may become a new avenue for custom-made fixed restoration design, analysis, and production in the 21st century.

  7. Zirconia as a Dental Biomaterial

    OpenAIRE

    Alvaro Della Bona; Pecho, Oscar E.; Rodrigo Alessandretti

    2015-01-01

    Ceramics are very important in the science of dental biomaterials. Among all dental ceramics, zirconia is in evidence as a dental biomaterial and it is the material of choice in contemporary restorative dentistry. Zirconia has been applied as structural material for dental bridges, crowns, inserts, and implants, mostly because of its biocompatibility, high fracture toughness, and radiopacity. However, the clinical success of restorative dentistry has to consider the adhesion to different subs...

  8. Dental ethics and emotional intelligence.

    Science.gov (United States)

    Rosenblum, Alvin B; Wolf, Steve

    2014-01-01

    Dental ethics is often taught, viewed, and conducted as an intell enterprise, uninformed by other noncognitive factors. Emotional intelligence (EQ) is defined distinguished from the cognitive intelligence measured by Intelligence Quotient (IQ). This essay recommends more inclusion of emotional, noncognitive input to the ethical decision process in dental education and dental practice.

  9. Dental operatory design and equipment.

    Science.gov (United States)

    Floyd, M

    1993-08-01

    Improving and expanding the dental services of a practice can involve purchasing new equipment and even modifying or expanding the physical plant. Operatory design is important to the efficiency with which dental procedures can be performed. Equipment purchases to outfit the dental operatory should be made based on the specific needs and functions of a practice.

  10. Dental Hygiene Realpolitik Affecting Education.

    Science.gov (United States)

    Bader, James D.

    1991-01-01

    Current conditions in dental hygiene influencing professional education are discussed. Workplace/practice issues include dental hygiene care as a component of dental practice, content, effects, and quality of care, hygienist supply and demand, and job satisfaction. Professional issues include the knowledge base, definitions of practice, and…

  11. Effects of surface treatment on bond strength between dental resin agent and zirconia ceramic

    Energy Technology Data Exchange (ETDEWEB)

    Moradabadi, Ashkan [Department of Electrochemistry, Universität Ulm, Ulm (Germany); Roudsari, Sareh Esmaeily Sabet [Department of Optoelectonics, Universität Ulm, Ulm (Germany); Yekta, Bijan Eftekhari [School of Materials Engineering, Iran University of Science and Technology, Tehran (Iran, Islamic Republic of); Rahbar, Nima, E-mail: nrahbar@wpi.edu [Department of Civil and Environmental Engineering, Worcester Polytechnic Institute, Worcester, MA 01609 (United States)

    2014-01-01

    This paper presents the results of an experimental study to understand the dominant mechanism in bond strength between dental resin agent and zirconia ceramic by investigating the effects of different surface treatments. Effects of two major mechanisms of chemical and micromechanical adhesion were evaluated on bond strength of zirconia to luting agent. Specimens of yttrium-oxide-partially-stabilized zirconia blocks were fabricated. Seven groups of specimens with different surface treatment were prepared. 1) zirconia specimens after airborne particle abrasion (SZ), 2) zirconia specimens after etching (ZH), 3) zirconia specimens after airborne particle abrasion and simultaneous etching (HSZ), 4) zirconia specimens coated with a layer of a Fluorapatite-Leucite glaze (GZ), 5) GZ specimens with additional acid etching (HGZ), 6) zirconia specimens coated with a layer of salt glaze (SGZ) and 7) SGZ specimens after etching with 2% HCl (HSGZ). Composite cylinders were bonded to airborne-particle-abraded surfaces of ZirkonZahn specimens with Panavia F2 resin luting agent. Failure modes were examined under 30 × magnification and the effect of surface treatments was analyzed by scanning electron microscopy (SEM) and atomic force microscopy (AFM). SZ and HSZ groups had the highest and GZ and SGZ groups had the lowest mean shear bond strengths among all groups. Mean shear bond strengths were significantly decreased by applying a glaze layer on zirconia surfaces in GZ and SGZ groups. However, bond strengths were improved after etching process. Airborne particle abrasion resulted in higher shear bond strengths compared to etching treatment. Modes of failure varied among different groups. Finally, it is concluded that micromechanical adhesion was a more effective mechanism than chemical adhesion and airborne particle abrasion significantly increased mean shear bond strengths compared with another surface treatments. - Highlights: • Understanding the dominant mechanism of bonding

  12. Dental amalgam: An update

    Directory of Open Access Journals (Sweden)

    Bharti Ramesh

    2010-01-01

    Full Text Available Dental amalgam has served as an excellent and versatile restorative material for many years, despite periods of controversy. The authors review its history, summarize the evidence with regard to its performance and offer predictions for the future of this material. The PubMed database was used initially; the reference list for dental amalgam featured 8641 articles and 13 publications dealing with recent advances in dental amalgam. A forward search was undertaken on selected articles and using some author names. For the present, amalgam should remain the material of choice for economic direct restoration of posterior teeth. When esthetic concerns are paramount, tooth-colored materials, placed meticulously, can provide an acceptable alternative. All alternative restorative materials and procedures, however, have certain limitations.

  13. Dental Implant Complications.

    Science.gov (United States)

    Liaw, Kevin; Delfini, Ronald H; Abrahams, James J

    2015-10-01

    Dental implants have increased in the last few decades thus increasing the number of complications. Since many of these complications are easily diagnosed on postsurgical images, it is important for radiologists to be familiar with them and to be able to recognize and diagnose them. Radiologists should also have a basic understanding of their treatment. In a pictorial fashion, this article will present the basic complications of dental implants which we have divided into three general categories: biomechanical overload, infection or inflammation, and other causes. Examples of implant fracture, loosening, infection, inflammation from subgingival cement, failure of bone and soft tissue preservation, injury to surround structures, and other complications will be discussed as well as their common imaging appearances and treatment. Lastly, we will review pertinent dental anatomy and important structures that are vital for radiologists to evaluate in postoperative oral cavity imaging.

  14. Dental Trauma Guide

    DEFF Research Database (Denmark)

    Andreasen, Jens Ove; Lauridsen, Eva; Gerds, Thomas Alexander

    2012-01-01

    Diagnosis and treatment for traumatic dental injuries are very complex owing to the multiple trauma entities represented by six luxation types and nine fracture types affecting both the primary and the permanent dentition. When it is further considered that fracture and luxation injuries are often...... combined, the result is that more than 100 trauma scenarios exist, when the two dentitions are combined. Each of these trauma scenarios has a specific treatment demand and prospect for healing. With such a complexity in diagnosis and treatment, it is obvious that even experienced practitioners may have...... problems in selecting proper treatment for some of these trauma types. To remedy this situation, an Internet-based knowledge base consisting of 4000 dental trauma cases with long-term follow up is now available to the public and the professions on the Internet using the address http://www.DentalTrauma...

  15. Dental formulations for the prevention of dental erosion

    DEFF Research Database (Denmark)

    2010-01-01

    The invention relates to a therapeutic method for preventing and/or inhibiting dental erosion in a mammalian subject, and the provision of a dental care product for performing the method. The dental care product of the invention comprises a starch-degrading enzyme of E. C. 3.2.1.1, wherein said...... product comprises less than 1 wt.% ionic surfactant, and preferably is substantially free of endoprotease and/or lipase. The properties of the dental care product serve to prevent and/or inhibit dental erosion in a subject that typically results from repeated exposure of the patient's tooth surfaces...

  16. Abrasive wear based predictive maintenance for systems operating in sandy conditions

    NARCIS (Netherlands)

    Woldman, M.; Tinga, T.; Heide, E. van der; Masen, M.A.

    2015-01-01

    Machines operating in sandy environments are damaged by the abrasive action of sand particles that enter the machine and become entrapped between components and contacting surfaces. In the case of the military services the combination of a sandy environment and the wide range of tasks to be fulfille

  17. Toothbrush abrasion, simulated tongue friction and attrition of eroded bovine enamel in vitro

    NARCIS (Netherlands)

    Vieira, A.; Overweg, E.; Ruben, J. L.; Huysmans, M. C. D. N. J. M.

    2006-01-01

    Objectives: Enamel erosion results in the formation of a softened layer that is susceptible to disruption by mechanical factors such as brushing abrasion, tongue friction and attrition. The aim of this study was to investigate the individual contribution of those mechanical insults to the enamel los

  18. Tapered toothbrush filaments in relation to gingival abrasion, removal of plaque and treatment of gingivitis

    NARCIS (Netherlands)

    Versteeg, P.A.; Piscaer, M.; Rosema, N.A.M.; Timmerman, M.F.; van der Velden, U.; van der Weijden, G.A.

    2008-01-01

    Objectives: To compare a tapered filament toothbrush (TFTB) to a control toothbrush (ADA) in their potential to cause gingival abrasion and improve the gingival condition following a period of experimental gingivitis. Methods: Thirty-two subjects refrained from brushing mandibular teeth for 21 days.

  19. The Effect of Microstructure on the Abrasion Resistance of Low Alloyed Steels

    NARCIS (Netherlands)

    Xu, X.

    2016-01-01

    The thesis attempts to develop advanced high abrasion resistant steels with low hardness in combination with good toughness, processability and low alloying additions. For this purpose, a novel multi-pass dual-indenter (MPDI) scratch test approach has been developed to approach the real continuous a

  20. Platelet response to corneal abrasion is necessary for acute inflammation and efficient re-epithelialization

    Science.gov (United States)

    Purpose: Adhesion molecules play a critical role in leukocyte emigration to wound sites, but differences are evident in different vascular beds. This study investigates the contributions of P-selectin to neutrophil emigration into the cornea following central epithelial abrasion. Methods: Re-epithel...

  1. NK cells modulate the inflammatory response to corneal epithelial abrasion and thereby support wound healing

    Science.gov (United States)

    Natural killer cells are lymphocytes of the innate immune system that have crucial cytotoxic and regulatory roles in adaptive immunity and inflammation. Herein, we consider a role for these cells in corneal wound healing. After a 2-mm central epithelial abrasion of the mouse cornea, a subset of clas...

  2. A review on nozzle wear in abrasive water jet machining application

    Science.gov (United States)

    Syazwani, H.; Mebrahitom, G.; Azmir, A.

    2016-02-01

    This paper discusses a review on nozzle wear in abrasive water jet machining application. Wear of the nozzle becomes a major problem since it may affect the water jet machining performance. Design, materials, and life of the nozzle give significance effect to the nozzle wear. There are various parameters that may influence the wear rate of the nozzle such as nozzle length, nozzle inlet angle, nozzle diameter, orifice diameter, abrasive flow rate and water pressure. The wear rate of the nozzle can be minimized by controlling these parameters. The mechanism of wear in the nozzle is similar to other traditional machining processes which uses a cutting tool. The high pressure of the water and hard abrasive particles may erode the nozzle wall. A new nozzle using a tungsten carbide-based material has been developed to reduce the wear rate and improve the nozzle life. Apart from that, prevention of the nozzle wear has been achieved using porous lubricated nozzle. This paper presents a comprehensive review about the wear of abrasive water jet nozzle.

  3. CONTROL SYSTEM EVALUATION AND IMPLEMENTATION FOR THE ABRASIVE MACHINING PROCESS ON WOOD

    Directory of Open Access Journals (Sweden)

    Stephen Jackson

    2011-06-01

    Full Text Available Continuous process improvement and automation have proven to be powerful tools for the wood processing industries in order to obtain better final product quality and thus increase profits. Abrasive machining represents an important and relevant process in the manufacturing and processing of wood products, which also implies high cost of materials and labor; therefore, special attention to this process is necessary. The objective of this work was to evaluate and demonstrate a process control system for use in the abrasive machining of wood and wood-based products. A control system was created on LabView® to integrate the monitoring process and the actions required, depending on the abrasive machining process conditions. The system acquires information from the optical sensor to detect loading and activate the cleaning system. The system continuously monitors the condition of the abrasive belt (tool wear by using an acoustic emission sensor and alerts the operator of the status of the belt (green, yellow, and red lights indicating satisfactory, medium, and poor belt condition. The system also incorporates an additional safety device, which helps prevent permanent damage to the belt, equipment, or workpiece by alerting the operator when an excessive temperature has been reached. The process control system proved that automation permits enhancement in the consistency of the belt cleaning technique by the elimination of the human errors. Furthermore, this improvement also affects the cost by extending the life of the belt, which reduces setup time, belt cost, operation cost, as well as others.

  4. Laser abrasion for cosmetic and medical treatment of facial actinic damage

    Energy Technology Data Exchange (ETDEWEB)

    David, L.M.; Lask, G.P.; Glassberg, E.; Jacoby, R.; Abergel, R.P.

    1989-06-01

    Previous studies have shown the carbon dioxide (CO/sub 2/) laser to be effective in the treatment of actinic cheilitis. After CO/sub 2/ laser abrasion, normal skin and marked cosmetic improvement of the lip were noted. In our study, twenty-three patients were treated with CO/sub 2/ laser abrasions for cosmetic improvement of facial lines and actinic changes. Pre- and postoperative histopathologic examinations were made on two patients. Preoperative examination of specimens from actinically damaged skin showed atypical keratinocytes in the basal layer of the epidermis, with overlying dense compact orthokeratosis and parakeratosis. Abundant solar elastosis was seen in the papillary dermis. Postoperative histologic specimens showed a normal-appearing epidermis with fibrosis in the papillary dermis and minimal solar elastosis (about four weeks after laser treatment). At present, various modalities are available for the regeneration of the aged skin, including chemical peels and dermabrasion. Significantly fewer complications were noted with CO/sub 2/ laser abrasion than with these methods. Thus, CO/sub 2/ laser abrasion can be useful in the cosmetic and medical treatment of the aged skin. Marked clinical and histologic improvement has been demonstrated.

  5. Raman study of diamond-based abrasives, and possible artefacts in detecting UHP microdiamond

    Science.gov (United States)

    Nasdala, Lutz; Steger, Simon; Reissner, Claudia

    2016-11-01

    Raman spectral characteristics of a range of diamond-based abrasives (powders and sprays) and drilling and cutting tools, originating from preparation laboratories worldwide, are presented. Some abrasives show strong broadening of the main diamond band [FWHM (full width at half band-maximum) > 5 cm- 1] accompanied by strong band-downshift (ν˜ = 1316-1330 cm- 1). Others are characterised by moderate band broadening (FWHM = 1.8-5 cm- 1) at rather regular band position (ν˜ = 1331-1333 cm- 1). In addition we found that a ;fresh; abrasive and its used analogue may in some cases show vast differences in their Raman spectra. The Raman parameters of diamond-based abrasives overlap widely with Raman parameters of UHP (ultra-high pressure) microdiamond. It is hence impossible to assign diamond detected in a geological specimen to either an introduced artefact or a genuine UHP relict, from the Raman spectrum alone. Raman is an excellent technique for the detection of minute amounts of diamond; however it does not provide conclusive evidence for the identification of UHP microdiamond. The latter requires thorough verification, for instance by optical microscopy or, if doubts cannot be dispelled, transmission electron microscopy.

  6. [Hardening of dental instruments].

    Science.gov (United States)

    Gerasev, G P

    1981-01-01

    The possibility of prolonging the service life of stomatological instruments by the local hardening of their working parts is discussed. Such hardening should be achieved by using hard and wear-resistant materials. The examples of hardening dental elevators and hard-alloy dental drills are given. New trends in the local hardening of instruments are the treatment of their working parts with laser beams, the application of coating on their surface by the gas-detonation method. The results of research work and trials are presented.

  7. Epilepsy in dental practice.

    Science.gov (United States)

    Fitzpatrick, J J; McArdle, N S; Wilson, M H; Stassen, L F A

    2008-01-01

    Epilepsy is a neurological condition characterised by seizure activity. It has an approximate incidence of 1%. General dental practitioners will encounter these patients in practice. This article discusses the types of epilepsy, the medical management and considerations in dental management of epileptic patients. General recommendations are made, based on current evidence, with respect to prescribing of medications. The management of an epileptic seizure is discussed. Status epilepticus is a rare but serious complication of epileptic seizures. An easy-to-follow algorithm is provided to assist the practitioner in managing seizures.

  8. Effects of surface treatment on bond strength between dental resin agent and zirconia ceramic.

    Science.gov (United States)

    Moradabadi, Ashkan; Roudsari, Sareh Esmaeily Sabet; Yekta, Bijan Eftekhari; Rahbar, Nima

    2014-01-01

    This paper presents the results of an experimental study to understand the dominant mechanism in bond strength between dental resin agent and zirconia ceramic by investigating the effects of different surface treatments. Effects of two major mechanisms of chemical and micromechanical adhesion were evaluated on bond strength of zirconia to luting agent. Specimens of yttrium-oxide-partially-stabilized zirconia blocks were fabricated. Seven groups of specimens with different surface treatment were prepared. 1) zirconia specimens after airborne particle abrasion (SZ), 2) zirconia specimens after etching (ZH), 3) zirconia specimens after airborne particle abrasion and simultaneous etching (HSZ), 4) zirconia specimens coated with a layer of a Fluorapatite-Leucite glaze (GZ), 5) GZ specimens with additional acid etching (HGZ), 6) zirconia specimens coated with a layer of salt glaze (SGZ) and 7) SGZ specimens after etching with 2% HCl (HSGZ). Composite cylinders were bonded to airborne-particle-abraded surfaces of ZirkonZahn specimens with Panavia F2 resin luting agent. Failure modes were examined under 30× magnification and the effect of surface treatments was analyzed by scanning electron microscopy (SEM) and atomic force microscopy (AFM). SZ and HSZ groups had the highest and GZ and SGZ groups had the lowest mean shear bond strengths among all groups. Mean shear bond strengths were significantly decreased by applying a glaze layer on zirconia surfaces in GZ and SGZ groups. However, bond strengths were improved after etching process. Airborne particle abrasion resulted in higher shear bond strengths compared to etching treatment. Modes of failure varied among different groups. Finally, it is concluded that micromechanical adhesion was a more effective mechanism than chemical adhesion and airborne particle abrasion significantly increased mean shear bond strengths compared with another surface treatments.

  9. Structural transformations and wear resistance of abrasive-affected amorphous Fe- and Co-based alloys

    Science.gov (United States)

    Korshunov, L. G.; Chernenko, N. L.

    2008-12-01

    The abrasive wear resistance of the Fe64Co30Si3B3, Fe82.6Nb5Cu3Si8B1.4, Co86.5Cr4Si7B2.5, and Fe81Si4B13C2 amorphous alloys (ribbon 30 μm thick) has been investigated upon sliding over fixed abrasives (corundum and silicon carbide). The character of fracture of the surface and structural transformations initiated in these materials by the abrasive action have been studied by the metallographic, X-ray diffraction, and electron-microscopic methods. It has been shown that the abrasive wear resistance of the amorphous alloys is smaller by a factor of 1.6-2.9 than that of the Kh12M and U8 tool steels possessing approximately the same level of hardness. A pronounced softening of the surface layer of the amorphous alloys in the process of wear, which is characterized by a decrease in their microhardness reaching 12.5%, has been found. It has been shown that in the surface layer of these amorphous alloys upon wear there arises a small amount (on the order of several volume percent) of the nanocrystalline structure, which does not exert a marked effect on the microhardness and wear resistance of the alloys. In the alloys under study, the main factor that is responsible for their comparatively low abrasive wear resistance is their local softening in the process of wear caused by specific features of deformation processes occurring heterogeneously under the action of high shear contact stresses.

  10. Alaska Dental Health Aide Program

    Directory of Open Access Journals (Sweden)

    Sarah Shoffstall-Cone

    2013-08-01

    Full Text Available Background. In 1999, An Oral Health Survey of American Indian and Alaska Native (AI/AN Dental Patients found that 79% of 2- to 5-year-olds had a history of tooth decay. The Alaska Native Tribal Health Consortium in collaboration with Alaska’s Tribal Health Organizations (THO developed a new and diverse dental workforce model to address AI/AN oral health disparities. Objectives. This paper describes the workforce model and some experience to date of the Dental Health Aide (DHA Initiative that was introduced under the federally sanctioned Community Health Aide Program in Alaska. These new dental team members work with THO dentists and hygienists to provide education, prevention and basic restorative services in a culturally appropriate manner. Results. The DHA Initiative introduced 4 new dental provider types to Alaska: the Primary Dental Health Aide, the Expanded Function Dental Health Aide, the Dental Health Aide Hygienist and the Dental Health Aide Therapist. The scope of practice between the 4 different DHA providers varies vastly along with the required training and education requirements. DHAs are certified, not licensed, providers. Recertification occurs every 2 years and requires the completion of 24 hours of continuing education and continual competency evaluation. Conclusions. Dental Health Aides provide evidence-based prevention programs and dental care that improve access to oral health care and help address well-documented oral health disparities.

  11. Drugs that promote dental caries.

    Science.gov (United States)

    2015-02-01

    Dental caries result from erosion of tooth enamel or cementum by acidic substances produced by bacteria found in dental plaque. Caries can lead to pulp necrosis and tooth loss. Risk factors include certain dietary habits, poor oral hygiene, and dry mouth. Diabetes and Sjogren's syndrome can also promote dental caries. Psychotropic substances such as cocaine, methamphetamine, heroin and cannabis can promote dental caries. Many medicinal drugs facilitate the formation of dental caries, through various mechanisms; they include formulations with a high sugar content; drugs that cause dry mouth (especially antimuscarinics); drugs that lower the buccal pH (inhaled powders, etc.); and drugs that cause demineralisation (tetracyclines, etc.). In practice, patients (and parents) should be informed that some drugs can increase the risk of dental caries. They should be encouraged to adapt and reinforce dental hygiene, and advised to visit a dentist regularly.

  12. Eighteenth and nineteenth century dental restoration, treatment and consequences in a British nobleman.

    Science.gov (United States)

    Cox, M; Chandler, J; Boyle, A; Kneller, P; Haslam, R

    2000-12-01

    This paper examines unusual eighteenth and nineteenth century dental treatment and its consequences, in a nobleman excavated from beneath St. Nicholas' Church, Sevenoaks, Kent, UK in the early 1990s. This rare archaeological case exhibits erosion of dental enamel on the labial surface of all the anterior dentition. A programme of historical research suggests that this might be attributed to the application of an acid-based dental tincture or the use of an abrasive substance to whiten the teeth. Palliative treatment for the consequence of this application was prescribed by Dr Robert Blake of Dublin. Further, it bears witness to three dental restorations, two of gold and one tin. The two gold (foil) fillings are an occlusal in the upper-right second molar and a cervical on the labial surface of the upper left canine. The tin filling is an occlusal in the upper left second molar. Excavation of the carious tissue appears to have been undertaken using a spoon shaped implement.

  13. Dental fluorosis in cattle

    Energy Technology Data Exchange (ETDEWEB)

    Narozny, J.

    1965-01-01

    Dental fluorosis in cattle was used as an indicator of toxic effects produced by fluorine emissions from an aluminium factory. Data are presented on the effects of a ten-year exposure to fluorides on cattle teeth. Emissions from the factory were observed in two directions from the factory, and extended as far as 16 km from the source.

  14. Kondensasi Pada Dental Amalgam

    OpenAIRE

    Batubara, Runi Syahriani

    2011-01-01

    Amalgam merupakan campuran dari dua atau beberapa logam (alloy) yang salah satunya adalah merkuri. Kata amalgam juga didefenisikan untuk menggambarkan kombinasi atau campuran dari beberapa bahan seperti merkuri, perak, timah, tembaga, dan lainnya. Dental amalgam sendiri adalah kombinasi alloy dengan merkuri melalui suatu proses yang disebut amalgamasi. Pemanipulasian amalgam meliputi triturasi, kondensasi, carving, dan polishing. Kondensasi merupakan penekanan amalgam setelah triturasi p...

  15. Mouth and dental disorders

    NARCIS (Netherlands)

    de Baat, C.; van der Waal, I.; Jackson, S.H.D.; Jansen, P.A.F.; Mangoni, A.A.

    2009-01-01

    Summary This chapter contains sections titled: • Introduction • Periodontal disease • Dental caries • Odontogenic infections • Alveolar osteitis • Xerostomia and hyposalivation • Candidiasis • Angular cheilitis • Denture stomatitis • Burning mouth syndrome • Recurrent aphthous stomatitis • Recurrent

  16. Advances in dental materials.

    Science.gov (United States)

    Fleming, Garry J P

    2014-05-01

    The dental market is replete with new resorative materials marketed on the basis of novel technological advances in materials chemistry, bonding capability or reduced operator time and/or technique sensitivity. This paper aims to consider advances in current materials, with an emphasis on their role in supporting contemporary clinical practice.

  17. Dental Hygiene Student Attrition.

    Science.gov (United States)

    Young, Lynda J.; Fellows, Avis L.

    1981-01-01

    A study to determine differences between graduating and withdrawing students in the University of Minnesota Dental Hygiene program is discussed. The identification of differences may prove useful in the selection process for future classes through identification of students likely to complete their education. (MLW)

  18. Dental Optical Coherence Tomography

    Directory of Open Access Journals (Sweden)

    Kun-Feng Lin

    2013-07-01

    Full Text Available This review paper describes the applications of dental optical coherence tomography (OCT in oral tissue images, caries, periodontal disease and oral cancer. The background of OCT, including basic theory, system setup, light sources, spatial resolution and system limitations, is provided. The comparisons between OCT and other clinical oral diagnostic methods are also discussed.

  19. An abrasion-resistant and broadband antireflective silica coating by block copolymer assisted sol-gel method.

    Science.gov (United States)

    Zou, Liping; Li, Xiaoguang; Zhang, Qinghua; Shen, Jun

    2014-09-02

    A double-layer broadband antireflective (AR) coating was prepared on glass substrate via sol-gel process using two kinds of acid-catalyzed TEOS-derived silica sols. The relative dense layer with a porosity of ∼10% was obtained from an as-prepared sol, while the porous layer with a porosity of ∼55% was from a modified one with block copolymer (BCP) Pluronic F127 as template which results in abundant ordered mesopores. The two layers give rise to a reasonable refractive index gradient from air to the substrate and thus high transmittance in a wide wavelength range, and both of them have the same tough skeleton despite different porosity, for which each single-layer and the double-layer coatings all behaved well in the mechanical property tests. The high transmittance and the strong ability of resisting abrasion make this coating promising for applications in some harsh conditions. In addition, the preparation is simple, low-cost, time-saving, and flexible for realizing the optical property.

  20. Effect of heat treatment on strength and abrasive wear behaviour of Al6061–SiCp composites

    Indian Academy of Sciences (India)

    N R Prabhu Swamy; C S Ramesh; T Chandrashekar

    2010-02-01

    In recent years, aluminum alloy based metal matrix composites (MMC) are gaining importance in several aerospace and automobile applications. Aluminum 6061 has been used as matrix material owing to its excellent mechanical properties coupled with good formability and its wide applications in industrial sector. Addition of SiCp as reinforcement in Al6061 alloy system improves its hardness, tensile strength and wear resistance. In the present investigation Al6061–SiCp composites was fabricated by liquid metallurgy route with percentages of SiCp varying from 4 wt% to 10 wt% in steps of 2 wt%. The cast matrix alloy and its composites have been subjected to solutionizing treatment at a temperature of 530°C for 1 h followed by quenching in different media such as air, water and ice. The quenched samples are then subjected to both natural and artificial ageing. Microstructural studies have been carried out to understand the nature of structure. Mechanical properties such as microhardness, tensile strength, and abrasive wear tests have been conducted both on matrix Al6061 and Al6061–SiCp composites before and after heat treatment. However, under identical heat treatment conditions, adopted Al6061–SiCp composites exhibited better microhardness and tensile strength reduced wear loss when compared with Al matrix alloy.

  1. Dental anxiety and salivary cortisol levels before urgent dental care.

    Science.gov (United States)

    Kanegane, Kazue; Penha, Sibele S; Munhoz, Carolina D; Rocha, Rodney G

    2009-12-01

    Dental anxiety is still prevalent, despite advances in treatment, and affects the utilization of health care services. The purpose of this cross-sectional study was to determine if patients with different degrees of dental anxiety and pain undergoing emergency dental care have different stress reactions as measured by salivary cortisol. Seventy three patients completed the modified dental anxiety scale (MDAS), and described any previous dental traumatic experience. Their socio-demographic characteristics were also recorded. They also rated pain intensity on a 100 mm visual analogue scale (VAS). A saliva sample was collected before the procedure, and analyzed by enzyme immunoassay. Thirty patients were dentally anxious and forty one complained of pain. In this sample, dental anxiety was not related to gender, age, educational level and family income; however, a previous traumatic event was related to dental anxiety. There was no association between salivary cortisol concentrations and gender or dental anxiety. Patients with pain showed higher cortisol levels. When gathering patient information, the dentist should note patients' negative dental experiences in order to provide more effective, less traumatic treatment.

  2. Thermocamera studies of nitrous oxide dispersion in the dental surgery

    Energy Technology Data Exchange (ETDEWEB)

    Carlsson, P.; Hallen, B.; Hallonsten, A.L.; Ljungqvist, B.

    1983-06-01

    Nitrous oxide is used in dentistry for sedation and analgesia. Chronic occupational exposure of dental personnel to trace concentrations of nitrous oxide has been reported as a potential health hazard. A new application of the thermocamera technique was used to study the dispersion of nitrous oxide during dental analgesia. Four breathing systems with different evacuation systems were tested and found to vary in scavenging efficiency. A local exhaust system ensured minimal exposure when nitrous oxide leaks contaminating the air in the dentist's breathing zone occur.

  3. 21 CFR 872.3240 - Dental bur.

    Science.gov (United States)

    2010-04-01

    ... materials intended for use in the fabrication of dental devices. (b) Classification. Class I (general... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dental bur. 872.3240 Section 872.3240 Food and... DENTAL DEVICES Prosthetic Devices § 872.3240 Dental bur. (a) Identification. A dental bur is a...

  4. Dental Therapy Assistant: Attitudes of Army Dentists.

    Science.gov (United States)

    Heid, Theodore H.; Bair, Jeffrey H.

    The U. S. Army Dental Corps has implemented a formal program based on the concept that dental care can be more efficiently and effectively provided with treatment teams composed of one dental officer, two dental therapy assistants, one basic assistant, and the shared support of other auxiliary personnel. Such a team will use three dental treatment…

  5. Prevalence of Dental Fear and Anxiety amongst Patients in Selected Dental Clinics in Ghana

    Science.gov (United States)

    Ofori, Marian A.; Adu-Ababio, F.; Nyako, E. A.; Ndanu, Tom A.

    2009-01-01

    Objective: To find out the prevalence of dental anxiety and fear amongst patients in various selected dental clinics in Accra, Ghana. Study design: Dental patients (n = 279) who had either been exposed to dental treatments or had no prior dental exposure, attending four selected dental clinics in Accra were randomly sampled. They were interviewed…

  6. Micro-abrasion-corrosion behaviour of a biomedical Ti-25Nb-3Mo-3Zr-2Sn alloy in simulated physiological fluid.

    Science.gov (United States)

    Wang, Zhenguo; Li, Yan; Huang, Weijiu; Chen, Xiaoli; He, Haoran

    2016-10-01

    The micro-abrasion-corrosion behaviour of the biomedical Ti-25Nb-3Mo-3Zr-2Sn alloy in Hank׳s solution with protein has been investigated using electrochemical measurements, tribological tests and scanning electron microscope (SEM) observations. The potentiodynamic polarization tests showed that the corrosion potential (Ecorr) exhibits the maximum value at the abrasive concentration of 0.05gcm(-3) despite of the load level. The tribological results indicated that the total material loss of the Ti-25Nb-3Mo-3Zr-2Sn alloy during micro-abrasion increased with the increasing abrasive concentration at a certain applied load. When the abrasive concentration is no more than 0.15gcm(-3), the total material loss increases with increasing load, while the total material loss exhibits the maximum value at a moderate load in case of higher abrasive concentration levels. This was ascribed to the three-body or two-body micro-abrasion-corrosion at different abrasive concentration levels. The wastage map, abrasion mode map and synergy map associated with the applied load and the abrasive concentration were constructed to evaluate the micro-abrasion-corrosion behaviour of the Ti-25Nb-3Mo-3Zr-2Sn alloy in potential biomedical applications.

  7. Abrasion and erosion testing of materials used in power production from coal

    Energy Technology Data Exchange (ETDEWEB)

    Tylczak, Joseph H.; Adler, Thomas A.; Rawers, James C.

    2003-09-01

    The Albany Research Center (ARC) has a long history of studying abrasive wear, related to mineral testing, handling, and processing. The center has also been instrumental in the design and development of wear test procedures and equipment. Research capabilities at ARC include Pin-on-Drum, Pin-on-Disk, and Dry Sand/Rubber Wheel abrasion tests, Jaw Crusher gouging test, Ball-on-Ball Impact test, and Jet erosion tests. Abrasive and erosive wear studies have been used to develop both new alloys and improved heat treatments of commercial alloys. As part of ARC’s newest iteration on wear testing to evaluate materials for use in new and existing pulverized coal combustion and gasifier power systems, the ARC has designed and constructed a new High Temperature Hostile Atmosphere Erosion Wear Test (HAET). This new piece of test apparatus is designed for erosive particle velocities of 10-40 m/sec and temperatures from room temperature (23°C) to 800+°C, with special control over the gas atmosphere. A variable speed whirling arm design is used to vary the impact energy of the gravity fed erosive particles. The specimens are mounted at the edge of a disk and allow a full range of impingement angles to be selected. An electric furnace heats the specimens in an enclosed retort to the selected temperature. Tests include both oxidizing conditions and reducing conditions. A range of gases, including CO, CO2, CH4, H2, H2S, HCl, N2, O2, and SO2 can be mixed and delivered to the retort. During the erosion testing a stream of abrasive powder is delivered in front of the specimens. This apparatus is designed to use low abrasive fluxes, which simulate real operating conditions in commercial power plants. Currently ~270 μm SiO2 particles are being used to simulate the abrasive impurities typically found in coal. Since operators are always striving for longer lifetimes and higher operating temperatures, this apparatus can help elucidate mechanisms of wastage and identify superior

  8. Testing of Alternative Abrasives for Water-Jet Cutting at C Tank Farm

    Energy Technology Data Exchange (ETDEWEB)

    Krogstad, Eirik J.

    2013-08-01

    Legacy waste from defense-related activities at the Hanford Site has predominantly been stored in underground tanks, some of which have leaked; others may be at risk to do so. The U.S. Department of Energy’s goal is to empty the tanks and transform their contents into more stable waste forms. To do so requires breaking up, and creating a slurry from, solid wastes in the bottoms of the tanks. A technology developed for this purpose is the Mobile Arm Retrieval System. This system is being used at some of the older single shell tanks at C tank farm. As originally planned, access ports for the Mobile Arm Retrieval System were to be cut using a high- pressure water-jet cutter. However, water alone was found to be insufficient to allow effective cutting of the steel-reinforced tank lids, especially when cutting the steel reinforcing bar (“rebar”). The abrasive added in cutting the hole in Tank C-107 was garnet, a complex natural aluminosilicate. The hardness of garnet (Mohs hardness ranging from H 6.5 to 7.5) exceeds that of solids currently in the tanks, and was regarded to be a threat to Hanford Waste Treatment and Immobilization Plant systems. Olivine, an iron-magnesium silicate that is nearly as hard as garnet (H 6.5 to 7), has been proposed as an alternative to garnet. Pacific Northwest National Laboratory proposed to test pyrite (FeS2), whose hardness is slightly less (H 6 to 6.5) for 1) cutting effectiveness, and 2) propensity to dissolve (or disintegrate by chemical reaction) in chemical conditions similar to those of tank waste solutions. Cutting experiments were conducted using an air abrader system and a National Institute of Standards and Technology Standard Reference Material (SRM 1767 Low Alloy Steel), which was used as a surrogate for rebar. The cutting efficacy of pyrite was compared with that of garnet and olivine in identical size fractions. Garnet was found to be most effective in removing steel from the target; olivine and pyrite were less

  9. Dental radiology instructors in United States dental hygiene programs.

    Science.gov (United States)

    Farman, A G; Hunter, N; Grammer, S

    1985-09-01

    A survey of dental radiology instructors in accredited United States dental hygiene programs found the majority of such faculty members to be registered dental hygienists with only very limited formal training in radiology. Most of the radiography faculty had less than 5 years' experience teaching that subject. Most instructors spent less than a quarter of each week teaching radiology. Student: faculty ratios varied considerably from program to program.

  10. Importance of Dental Records in Forensic Dental Identification

    OpenAIRE

    Waleed, Petro; Baba, Feras; Alsulami, Salem; Tarakji, Bassel

    2015-01-01

    Introduction: The patient’s record maintains all the diagnostic information with regards to patients and contains valuable information that can be beneficial to the dentist as well as legal authorities during forensic human identification. Aim: Objective of the study was to compare dental records with an ideal dental record form, as well as to compare between dental records of private clinics and academic hospitals and to assess the awareness and the knowledge of the dentists regarding the ma...

  11. Teasing apart the contributions of hard dietary items on 3D dental microtextures in primates.

    Science.gov (United States)

    Calandra, Ivan; Schulz, Ellen; Pinnow, Mona; Krohn, Susanne; Kaiser, Thomas M

    2012-07-01

    3D dental microtexture analysis is a powerful tool for reconstructing the diets of extinct primates. This method is based on the comparison of fossils with extant species of known diet. The diets of primates are highly diversified and include fruits, seeds, grass, tree leaves, bark, roots, tubers, and animal resources. Fruits remain the main component in the diets of most primates. We tested whether the proportion of fruit consumed is correlated with dental microtexture. Two methods of microtexture analysis, the scale-sensitive fractal analysis (SSFA) and the Dental Areal Surface Texture Analysis (DASTA; after ISO/FDIS 25178-2), were applied to specimens of eight primate species (Alouatta seniculus, Gorilla gorilla, Lophocebus albigena, Macaca fascicularis, Pan troglodytes, Papio cynocephalus, Pongo abelii, Theropithecus gelada). These species largely differ in the mean annual proportion of fruit (from 0 to 90%) in their diet, as well as in their consumption of other hard items (seeds, bark, and insect cuticles) and of abrasive plants. We find the complexity and heterogeneity of textures (SSFA) to correlate with the proportion of fruits consumed. Textural fill volume (SSFA) indicates the proportion of both fruits and other hard items processed. Furthermore, anisotropy (SSFA) relates to the consumption of abrasive plants like grass and other monocots. ISO parameters valley height, root mean square height, material volume, density of peaks, and closed hill and dale areas (DASTA) describe the functional interaction between food items and enamel facets during mastication. The shallow, plastic deformation of enamel surfaces induced by small hard particles, such as phytoliths or dust, results in flat microtexture relief, whereas the brittle, deep fracture caused by large hard items such as hard seeds creates larger relief.

  12. Dental Trauma Guide

    DEFF Research Database (Denmark)

    Andreasen, Jens Ove; Lauridsen, Eva Fejerskov; Christensen, Søren Steno Ahrensburg

    2012-01-01

    Diagnose and treatment of traumatic dental injuries is very complex due to the multiple trauma entities represented by 6 lunation types and 9 fracture types affecting both the primary and the permanent dentition. When it is further considered that fracture and lunation injuries are often combined......, the result is, that more than 100 trauma scenario exist when the two dentitions are combined. Each of these trauma scenarios have a specific treatment demand and prospect for healing. With such a complexity in diagnose and treatment it is obvious that even experienced practitioners may have problems may have...... problems in selecting proper treatment for some of these trauma types. To remedy this situation, an internet based knowledge base consisting of 4000 dental trauma cases with long term follow up is now available to the public and professionals, on the internet using the address www...

  13. Dental artifacts in the head and neck region:

    DEFF Research Database (Denmark)

    Ladefoged, Claes N.; Hansen, Adam E.; Keller, Sune

    2015-01-01

    region of patients with dental implants. The purpose of this study was to assess the frequency and magnitude of subsequent PET image distortions following MR-AC. METHODS: A total of 148 PET/MR patients with clear visual signal voids on the attenuation map in the dental region were included in this study......BACKGROUND: In the absence of CT or traditional transmission sources in combined clinical positron emission tomography/magnetic resonance (PET/MR) systems, MR images are used for MR-based attenuation correction (MR-AC). The susceptibility effects due to metal implants challenge MR-AC in the neck...... substituted with soft tissue information. Our inpainting algorithm delineates the outer contour of signal voids breaching the anatomical volume using the non-attenuation-corrected PET image and classifies the inner air regions based on an aligned template of likely dental artifact areas. The reconstructed PET...

  14. Improvement of Surface Roughness Quality for Stainless Steel 420 Plate Using Magnetic Abrasive Finishing Method

    Directory of Open Access Journals (Sweden)

    Yahya M. Hamad

    2010-01-01

    Full Text Available An experimental study was carried out to improve the surface roughness quality of the stainless steel 420 using magnetic abrasive finishing method (MAF. Four independent operation parameters were studied (working gap, coil current, feed rate, and table stroke, and their effects on the MAF process were introduced. A rotating coil electromagnet was designed and implemented to use with plane surfaces. The magnetic abrasive powder used was formed from 33%Fe and 67% Quartz of (250µm mesh size. The lubricant type SAE 20W was used as a binder for the powder contents. Taguchi method was used for designing the experiments and the optimal values of the selected parameters were found. An empirical equation representing the relation between surface roughness with operation parameters have been achieved.

  15. Study on NDT Fault Diagnosis of the Ball Bearing under Stage of Abrasion by Infrared Thermography

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Jin Ju; Hong, Dong Pyo [Chonbuk National University, Jeonju (Korea, Republic of); Kim, Won Tae [Kongju National University, Gongju (Korea, Republic of)

    2012-02-15

    For fault detection about the abrasion stage of rotational machineries under the dynamic loading conditions unlike the traditional diagnosis method used in the past decade, the infrared thermographic method with its distinctive advantages in non-contact, non-destructive, and visible aspects is proposed. In this paper, by applying a rotating deep-grooved ball bearing, passive thermographic experiments were conducted as an alternative way to proceeding the traditional fault monitoring on spectrum analyzer. As results, the thermographic experiment was compared with the traditional vibration spectrum analysis to evaluate the efficiency of the proposed method. Based on the results obtained as NDT, the temperature characteristics and abnormal fault detections of the ball bearing according to the abrasion stage were analyzed.

  16. Structure and Abrasive Wear of Composite HSS M2/WC Coating

    Directory of Open Access Journals (Sweden)

    S. F. Gnyusov

    2012-01-01

    Full Text Available Features of phase-structure formation and abrasive wear resistance of composite coatings “WC-M2 steel” worn against tungsten monocarbide have been investigated. It was established that adding 20 wt.% WC to the deposited powder mixture leads to the increase in M6C carbide content. These carbides show a multimodal size distribution consisting of ~5.9 μm eutectic carbides along the grain boundaries, ~0.25 μm carbides dispersed inside the grains. Also a greater amount of metastable austenite (~88 vol.% is found. The high abrasive wear resistance of these coatings is provided by γ→α′-martensitic transformation and multimodal size distribution of reinforcing particles.

  17. Structure and abrasive wear resistance of R6M5 steel-tungsten carbide composite coatings

    Science.gov (United States)

    Gnyusov, S. F.

    2012-09-01

    Features of the structure formation, composition, and abrasive wear resistance of R6M5 steel-tungsten carbide (R6M5-WC) composite coatings have been studied as dependent on the WC content. The introduction of ˜20 wt % WC into the hardening composition leads to an increase in the fraction of M6C carbide (in the form of eutectic inclusions with average size ˜5.9 μm at grain boundaries and dispersed ˜0.25 μm particles in the volume of grains), while a large proportion of metastable austenite (˜88 vol %) is still retained. The R6M5-WC coatings exhibit high abrasive wear resistance, which is ensured by the γ → α' martensite transformation during friction and a muiltimodal size distribution of hardening particles.

  18. Study on comprehensive properties of duplex austenitic surfacing alloys for impacting abrasion

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    In this paper, comprehensive property crack resistance, work hardening and abrasion resistance of a series of double-phases austenitic alloys(FAW) has been studied by means of SEM, TEM and type MD-10 impacting wear test machine. FAW alloys are of middle chromium and low manganese, including Fe-Cr-Mo-C alloy,Fe-Cr-Mn-C alloy and Fe-Cr-Mn-Ni-C alloy, that are designed for working in condition of impacting abrasion resistance hardfacing.Study results show that the work hardening mechanism of FAW alloys are mainly deformation high dislocation density and dynamic carbide aging, the form of wearing is plastic chisel cutting. Adjusting the amount of carbon, nickel, manganese and other elements in austenitic phase area, the FAW alloy could fit different engineering conditions of high impacting, high temperature and so on.

  19. Correlating field and laboratory rates of particle abrasion, Rio Medio, Sangre de Cristo Mountains, New Mexico

    Science.gov (United States)

    Polito, P. J.; Sklar, L. S.

    2006-12-01

    River bed sediments commonly fine downstream due to a combination of particle abrasion, selective transport of finer grains, and fining of the local sediment supply from hillslopes and tributaries. Particle abrasion rates can be directly measured in the laboratory using tumbling barrels and annular flumes, however, scaling experimental particle abrasion rates to the field has proven difficult due to the confounding effects of selective transport and local supply variations. Here we attempt to correlate laboratory and field rates of particle abrasion in a field setting where these confounding effects can be controlled. The Rio Medio, which flows westward from the crest of the Sangre de Cristo Mountains in north central New Mexico, is one of several streams studied by John P. Miller in the early 1960's. Several kilometers downstream of its headwaters, the river crosses the Picuris-Pecos fault. Upstream of the fault the river receives quartzite, sandstone and shale clasts from the Ortega Formation, while downstream sediments are supplied by the Embudo Granite. Because the upstream lithologies are not resupplied downstream of the fault, any observed fining of these clasts should be due only to abrasion and selective transport. We hypothesize that we can account for the effects of selective transport by comparing relative fining rates for the different upstream lithologies from both the field and a laboratory tumbler. By correlating laboratory abrasion rates with rock strength, we can predict the relative fining rates due solely to abrasion expected in the field; differences between the predicted and observed fining rates could then be attributed to selective transport. We used point counts to measure bed surface sediment grain size distributions at 15 locations along a 25 kilometer reach of the Rio Medio, beginning just downstream of the fault and ending upstream of a developed area with disturbed channel conditions. We recorded intermediate particle diameter as well

  20. Abrasive wear behaviour of bio-active glass ceramics containing apatite

    Indian Academy of Sciences (India)

    I Sevim; M K Kulekci

    2006-06-01

    In this study, abrasive wear behaviour of bio-active glass ceramic materials produced with two different processes is studied. Hot pressing process and conventional casting and controlled crystallization process were used to produce bio-active ceramics. Fracture toughness of studied material was calculated by fracture toughness equations using experimental hardness results of the bio-active glass ceramic material. Two fracture toughness equations in the literature were used to identify the wear behaviour of studied ceramics. Wear resistance results that identified with both of the equations were similar. The results showed that the abrasive wear resistance of the bio-active glass ceramics produced with hot pressing process was found to be higher than that of the ceramics produced by conventional casting and controlled crystallization process.

  1. A study on practical use of underwater abrasive water jet cutting

    Science.gov (United States)

    Yamaguchi, Hitoshi; Demura, Kenji

    1993-09-01

    The practicality of underwater abrasive water jet cutting technology was studied in experiments. A study of abrasives in slurried form showed that optimum polymer concentration can be selected to suit underwater conditions. For the long-distance transport of slurry from the ocean surface to the ocean floor, a direct supply system by hose proved to be practical. This system takes advantage of the insolubility of the slurry in water due to a difference in specific gravity. For cutting thick steel plate at great ocean depths, a simulation with a pressurized container revealed the requirements for actual cutting. Confirmation of remote cutting operations will become the most important technology in field applications. Underwater sound vibration characteristics were found to change significantly in direct response to modifications in cutting conditions. This will be important basic data to develop an effective sensoring method.

  2. Kerf modelling in abrasive waterjet milling using evolutionary computation and ANOVA techniques

    Science.gov (United States)

    Alberdi, A.; Rivero, A.; Carrascal, A.; Lamikiz, A.

    2012-04-01

    Many researchers demonstrated the capability of Abrasive Waterjet (AWJ) technology for precision milling operations. However, the concurrence of several input parameters along with the stochastic nature of this technology leads to a complex process control, which requires a work focused in process modelling. This research work introduces a model to predict the kerf shape in AWJ slot milling in Aluminium 7075-T651 in terms of four important process parameters: the pressure, the abrasive flow rate, the stand-off distance and the traverse feed rate. A hybrid evolutionary approach was employed for kerf shape modelling. This technique allowed characterizing the profile through two parameters: the maximum cutting depth and the full width at half maximum. On the other hand, based on ANOVA and regression techniques, these two parameters were also modelled as a function of process parameters. Combination of both models resulted in an adequate strategy to predict the kerf shape for different machining conditions.

  3. A New Method for Descaling Wool Fibres by Nano Abrasive Calcium Carbonate Particles in Ultrasonic Bath

    Directory of Open Access Journals (Sweden)

    Ali rezaghasemi

    2016-08-01

    Full Text Available Up to now, the most conventional methods for descaling of wool fibre are based on chemical degradation and resin covering of scales or a combination of them. These methods are producing wastewater and can cover physical properties of the fibres beside scales orderly. In this study, a new and clean method is developed on the basis of abrasion effect of calcium carbonate Nano particles (CCNP in an ultrasonic bath. Woolen Samples (fibre and yarn were sonicated with different levels of CCNP. Tensile properties of the yarns, directional friction effect of the fibres and scanning electron microscope images of the fibres were studied. Test results showed that sonicated Nano treatment of woolyarn reduced its tenacity, extension and work of rupture and increased its coefficient of friction. Scanning electron microscope images of fibres and measurement of fibres directional displacement confirmed descaling of Nano abrasive treated wool samples in comparison to the raw wool.

  4. Examining of abrasion resistance of hybrid composites reinforced with SiC and Cgr particles

    Directory of Open Access Journals (Sweden)

    M. Łągiewka

    2008-08-01

    Full Text Available The presented work discusses the influence of the type and volume percentage of particulate reinforcement consisting of mixed silicon carbide and graphite on the abrasion wear of hybrid composites with AlMg10 matrix. Also the macro photos of frictional surfaces have been shown and the results of hardness measurements have been presented. The performed examinations have allowed for stating that the mixture of SiC and Cgr particles changes in favour the tribological properties of the matrix alloy. It has been also proved that introducing hard reinforcing particles along with soft lubricating ones allows for achieving the material exhibiting high abrasion resistance, and moreover, the graphite particles protect the abraded surface from the destructive action of silicon carbide particles. Also hardness measurements have been performed and the resulting conclusion is that the composite hardness increases with an increase in volume fraction of the reinforcing particles.

  5. Influence of scale-up on the abrasion of tablets in a pan coater.

    Science.gov (United States)

    Mueller, Ronny; Kleinebudde, Peter

    2006-11-01

    The purpose of this study was to examine the influence of batch size during scale-up on the abrasion and edge splitting of flat faced lactose tablets. The weight loss of white tracer tablets in a batch of blue coated tablets was investigated in a laboratory scale pan coater and a pilot scale pan coater as a function of different pan speeds and mixing times. It was observed that increasing batch size resulted in a decreased weight loss due to less edge damaging. The higher number of tablet impacts at the pan wall in the laboratory scale compared to the pilot scale might be the reason for this phenomenon. The common assertion that an increase in batch size in scale-up leads to a higher abrasion or tablet damaging was not supported in the current study.

  6. Utilizing a Magnetic Abrasive Finishing Technique (MAF Via Adaptive Nero Fuzzy(ANFIS

    Directory of Open Access Journals (Sweden)

    Amer A. Moosa

    2015-07-01

    Full Text Available An experimental study was conducted for measuring the quality of surface finishing roughness using magnetic abrasive finishing technique (MAF on brass plate which is very difficult to be polish by a conventional machining process where the cost is high and much more susceptible to surface damage as compared to other materials. Four operation parameters were studied, the gap between the work piece and the electromagnetic inductor, the current that generate the flux, the rotational Spindale speed and amount of abrasive powder size considering constant linear feed movement between machine head and workpiece. Adaptive Neuro fuzzy inference system (ANFIS was implemented for evaluation of a series of experiments and a verification with respect to specimen roughness change has been optimized and usefully achieved by obtained results were an average of the error between the surface roughness predicted by model simulation and that of direct measure is 2.0222 %.

  7. STUDYING THE ABRASION BEHAVIOR OF RUBBERY MATERIALS WITH COMBINED DESIGN OF EXPERIMENT-ARTIFICIAL NEURAL NETWORK

    Institute of Scientific and Technical Information of China (English)

    Mehdi Shiva; Hossein Atashi; Mahtab Hassanpourfard

    2012-01-01

    In this study,an application of artificial neural network (ANN) has been presented in modeling and studying the effect of compounding variables on abrasion behavior of rubber formulations.Three case studies were carried out in which the experiment data were collected according to classical response surface designs.Besides developing the ANN models,we developed response surface methodology (RSM) to confirm the ANN predictions.A simple relation was employed for determination of relative importance of each variable according to ANN models.It was shown through these case studies that ANN models delivered very good data fitting and their simulating curves could help the researchers to better understand the abrasion behavior.

  8. American Academy of Dental Sleep Medicine

    Science.gov (United States)

    ... Your Education This Fall Membership Join the American Academy of Dental Sleep Medicine as a member and ... Henry Schein Dental Myerson/Frantz Design Copyright © American Academy of Dental Sleep Medicine, All Rights Reserved. American ...

  9. Relationship among wear-resistance of three-body abrasion,substructure and property in martensite steels

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    The effects of subsurface hardness on wear-resistance of martensitic steel 20Cr, 40CrSi, 60Mn, T8 and T10 in three-body abrasion under static load was investigated. It shows that the characteristic ofthe subsurface hardness distribution and the abrasive wear resistanceis related to the substructure near the worn surface. The substructure of the tested martensite steel has an apparent relationship with thecarbon content and steels with moderate carbon content and hardness exhibit good resistance to abrasive wear. The competition of the work-hardening effect and the temper softening effect, which resulted from deformation and friction heat generating during abrasive wear is considered to be a main reason for the relation among wear-resistance, hardness and substructure. At the test conditions, the wear-resistance of 40CrSi is the best.

  10. Relations of abrasion resistance and hardness of 16Cr-3C white irons with retained austenite content

    Institute of Scientific and Technical Information of China (English)

    Zhiping Sun; Rulin Zuo; Cong Li; Baoluo Shen; Shengji Gao; Sijiu Huang

    2004-01-01

    The relationship between the retained austenite content of the matrix in 16Cr-3C white irons and the abrasion resistance was investigated. The results show that: (1) the abrasion resistance can be improved by sub-critical heat treatment, which could be attributed to the decrease of the retained austenite content; (2) both the abrasion resistance and hardness can be improved by controlling the retained austenite content below 20%-30% and arrive at the maximum when the retained austenite content is reduced to about 10%; (3) the abrasion resistance decreases abruptly once the retained austenite content is lower than 10%, which stems from both the in situ transformation of (Fe, Cr)23C6 to M3C carbides and the formation of pearlitic matrix.

  11. [Phenomenon of dental fear].

    Science.gov (United States)

    Moore, R; Birn, H

    1990-01-01

    Odontophobia is a rather unique phobia with special psychosomatic components that impact on the dental health of odontophobic persons. It also has psychosocial components largely as a result of destruction of the teeth and subsequent embarrassment that can affect a person and cause a vicious cycle of dental fear. The phenomenon is facilitated by misunderstandings and myths generated by both patients and dentists. The most common reasons given in the literature for such strong fears of dental treatment are: 1) bad experiences in childhood for 85% of cases, 2) feeling of powerlessness and lack of control over personal emotional reactions and over the social situation in the dental chair, 3) social learning processes in which the image of the dentist is cast in a negative light by the mass media or by the person's relatives or friends and 4) that the person has other psychologic problems (in 20% of cases), such as serious phobias and/or neuroses. A strategy of researching and thus tackling the problem is presented which focuses on three essential targets that require studying and change: 1) the community at large and their image of the dentist, 2) the patient role and 3) the dentist role. Various model projects are presented along with their diagnostic systems. These are seen to focus in varying degrees on different elements of the target groups that effect the dentist-patient relationship but the need to come out into the community and make the social environment right for these patients is an important factor in all strategies.(ABSTRACT TRUNCATED AT 250 WORDS)

  12. TRICARE Dental Programs

    Science.gov (United States)

    2011-01-01

    Contract: Effective 1 October 2008  New Benefits – Dental Implants – 1 and 2 surface Posterior composite resins (white fillings)  Expanded Overseas...JAN 6, 2011  Follow-on Contract includes the following benefit enhancements – Composite resin fillings on posterior teeth – Increase of annual maximum...Specialists  Tendency for different materials ( amalgam , gold crowns and porcelain-fused to metal crowns (PFMs))  ADDP is Benefits Administration – no

  13. Dental calculus: Nanocharacterization

    OpenAIRE

    Grga, Đurica; Marjanović, Marina; Hut, Igor; Dželetović, Bojan; Koruga, Đuro

    2012-01-01

    Emerging technologies and new nanoscale information have potential to transform dental practice by improving all aspects of diagnostics and therapy. Nanocharacterization allows understanding of oral diseases at molecular and cellular levels which eventually can increase the success of prevention and treatment. Opto-magnetic spectroscopy (OMS) is a promising new technique based on light-matter interaction which allows insight into the quantum state of matter. Since biomolecules and tissues are...

  14. Dental Implants: Dual Stabilization Technology

    OpenAIRE

    Saini, Rajiv

    2015-01-01

    More recent epidemiological data seem to show an increasing trend of tooth loss due to periodontal reasons rather than caries; the presence of initial attachment loss, bone height and the habit of smoking significantly increase the risk of tooth mortality. A dental implant is a titanium screw which is placed into bone to replace missing teeth. The implant mimics the root of a tooth in function. Dental Implants have changed the face of dentistry over the last three decades. Success of dental i...

  15. Systemic disorders affecting dental pathology

    Directory of Open Access Journals (Sweden)

    Knežević Milan R

    2014-12-01

    Full Text Available A retrospective overview of systemic disorders which might be associated with dental pathology is made. They are grouped as follows: (a congenital dental developmental disorders, (b chromosomal anomalies, (c radiations, (d immune disorders, (e intoxications, (f neurological alterations, (g gastrointestinal diseases, (h osteodystrophy and associated conditions, (i skin diseases, (j metabolic and endocrine disorders, (k craniofacial malformation syndromes and other congenital general malformations. The associated dental pathology is described in each case.

  16. Sensibilidad dentaria Dental sensibility

    Directory of Open Access Journals (Sweden)

    P Tortolini

    2003-10-01

    Full Text Available La sensibilidad dentaria l es un problema común que se presenta entre el 9 y el 30% de la población adulta. La teoría hidrodinámica es aceptada como uno de los mecanismos de inducción de la respuesta pulpar dolorosa, debido a que los estímulos provocan el movimiento del fluido y para ello es necesario que la dentina este expuesta y que los túbulos dentinarios estén abiertos y permeables a la pulpa. Es fundamental realizar el diagnostico diferencial con otras causas de dolor dental e identificar los factores etiológicos y predisponentes.Dental sensitivity is a common problem and it affect 9 and 30% the adult poblation. The hidrodynamyc theory is cited as the menchanism of induction of a painful pulpal response and implies that stimuli tranmission across dentine increase the rate of fluid flow through dentinal tubules and for this to accur the dentinal tubules must be opened andpermeable to the pulp. An appropiate tretametn needs a diferential diagnosis eith other causes of dental pain and the identification of predisponing etiologic factors.

  17. Treatment of gingival hyperpigmentation with rotary abrasive, scalpel, and laser techniques: A case series

    OpenAIRE

    Murthy, M Bhanu; Kaur, Jasjit; Das, Rupali

    2012-01-01

    Melanin pigmentation often occurs in the gingiva as a result of an abnormal deposition of melanin, due to which the gums may appear black, but the principles, techniques, and management of the problems associated with gingival melanin pigmentation are still not fully established. Depigmentation procedures such as scalpel surgery, gingivectomy with free gingival autografting, electrosurgery, cryosurgery, chemical agents such as 90% phenol and 95% alcohol, abrasion with diamond bur, Nd: YAG las...

  18. Experimental Investigations into Abrasive Waterjet Machining of Carbon Fiber Reinforced Plastic

    Directory of Open Access Journals (Sweden)

    Prasad D. Unde

    2015-01-01

    Full Text Available Abrasive waterjet machining (AWJM is an emerging machining process in which the material removal takes place due to abrasion. A stream of abrasive particles mixed with filtered water is subjected to the work surface with high velocity. The present study is focused on the experimental research and evaluation of the abrasive waterjet machining process in order to evaluate the technological factors affecting the machining quality of CFRP laminate using response surface methodology. The standoff distance, feed rate, and jet pressure were found to affect kerf taper, delamination, material removal rate, and surface roughness. The material related parameter, orientation of fiber, has been also found to affect the machining performance. The kerf taper was found to be 0.029 for 45° fiber orientation whereas it was 0.036 and 0.038 for 60° and 90°, respectively. The material removal rate is 18.95 mm3/sec for 45° fiber orientation compared to 18.26 mm3/sec for 60° and 17.4 mm3/sec for 90° fiber orientation. The Ra value for 45° fiber orientation is 4.911 µm and for 60° and 90° fiber orientation it is 4.927 µm and 4.974 µm, respectively. Delamination factor is found to be more for 45° fiber orientation, that is, 2.238, but for 60° and 90° it is 2.029 and 2.196, respectively.

  19. Investigation of sandwich material surface created by abrasive water jet (AWJ via vibration emission

    Directory of Open Access Journals (Sweden)

    P. Hreha

    2014-01-01

    Full Text Available The paper presents research a of abrasive waterjet cutting of heterogeneous “sandwich“ material with different Young modulus of elasticity of the cutted surface geometry by means of vibration emission. In order to confirm hypothetical assumptions about direct relation between vibration emission and surface quality an experiment in heterogeneous material consisting of stainless steel (DIN 1.4006 / AISI 410 and alloy AlCuMg2 has been provided.

  20. Micro-scale abrasion behaviour of electroless Ni-P-SiC coating on aluminium alloy

    OpenAIRE

    2014-01-01

    Electroless nickel (EN) and electroless nickel composite (ENC) coatings were deposited on aluminium alloy substrate, LM24. The micro abrasion test was conducted to study the wear behaviour of the coatings with the effect of SiC concentration. Microhardness of the coatings was tested also. The wear scars were analysed using optical microscope and scanning electron microscope (SEM). The wear resistance was found to be improved in composite coating that has higher microhardness as compared to pa...

  1. Abrasive Wear Performance of Aluminium Modified Epoxy-Glass Fiber Composites

    Science.gov (United States)

    Kamble, Vikram G.; Mishra, Punyapriya; Al Dabbas, Hassan A.; Panda, H. S.; Fernandez, Johnathan Bruce

    2015-07-01

    For a long time, Aluminum filled epoxies molds have been used in rapid tooling process. These molds are very economical when applied in manufacturing of low volume of plastic parts. To improve the thermal conductivity of the material, the metallic filler material is added to it and the glass fiber improves the wear resistance of the material. These two important parameters establish the life of composites. The present work reports on abrasive wear behavior of Aluminum modified epoxy and glass fiber composite with 5 wt.% and 10 wt.% of aluminum particles. Through pin on disc wear testing machine, we studied the wear behaviors of composites, and all these samples were fabricated by using hand layup process. Epoxy resin was used as matrix material which was reinforced with Glass fiber and Aluminum as filler. The composite with 5 wt.% and 10 wt.% of Al was cast with dimensions 100 × 100 × 6 mm. The specimens were machined to a size of 6 × 6 × 4 mm for abrasive testing. Abrasive tests were carried out for different grit paper sizes, i.e., 150, 320, 600 at different sliding distance, i.e., 20, 40, 60 m at different loads of 5, 10 and 15 N and at constant speed. The weight loss due to wear was calculated along with coefficient of friction. Hardness was found using Rockwell hardness machine. The SEM morphology of the worn out surface wear was analyzed to understand the wear mechanism. Results showed that the addition of Aluminum particles was beneficial for low abrasive conditions.

  2. Abrasive Wear Resistance of Tool Steels Evaluated by the Pin-on-Disc Testing

    Science.gov (United States)

    Bressan, José Divo; Schopf, Roberto Alexandre

    2011-05-01

    Present work examines tool steels abrasion wear resistance and the abrasion mechanisms which are one main contributor to failure of tooling in metal forming industry. Tooling used in cutting and metal forming processes without lubrication fails due to this type of wear. In the workshop and engineering practice, it is common to relate wear resistance as function of material hardness only. However, there are others parameters which influences wear such as: fracture toughness, type of crystalline structure and the occurrence of hard precipitate in the metallic matrix and also its nature. In the present investigation, the wear mechanisms acting in tool steels were analyzed and, by normalized tests, wear resistance performance of nine different types of tool steels were evaluated by pin-on-disc testing. Conventional tool steels commonly used in tooling such as AISI H13 and AISI A2 were compared in relation to tool steels fabricated by sintering process such as Crucible CPM 3V, CPM 9V and M4 steels. Friction and wear testing were carried out in a pin-on-disc automated equipment which pin was tool steel and the counter-face was a abrasive disc of silicon carbide. Normal load of 5 N, sliding velocity of 0.45 m/s, total sliding distance of 3000 m and room temperature were employed. The wear rate was calculated by the Archard's equation and from the plotted graphs of pin cumulated volume loss versus sliding distance. Specimens were appropriately heat treated by quenching and three tempering cycles. Percentage of alloying elements, metallographic analyses of microstructure and Vickers microhardness of specimens were performed, analyzed and correlated with wear rate. The work is concluded by the presentation of a rank of tool steel wear rate, comparing the different tool steel abrasion wear resistance: the best tool steel wear resistance evaluated was the Crucible CPM 9V steel.

  3. An Research on Abrasion Resistance of Muzzle Shunt Rail Gun Rail Boronized with Self-protecting B4C Paste

    Institute of Scientific and Technical Information of China (English)

    HUJin-suo; CHENGShu-kang; ZHENGZhen-zhong; MAYuan; LIZhi-yuan

    2004-01-01

    Based on large numbers of experiments, together with some theoretic support such as equations related to the experiment, thermodynamic principles and so on, one useful and reasonable self-protecting boron formulation is got to reintorce the muzzle shunt rail gun rail. The preliminary friction and abrasion test results show that the formulation is acceptable and the abrasion resistance of the steel rail enhances to some extent after the surface reinforcement.

  4. An Research on Abrasion Resistance of Muzzle Shunt Rail Gun Rail Boronized with Self-protecting B4C Paste

    Institute of Scientific and Technical Information of China (English)

    HU Jin-suo; CHENG Shu-kang; ZHENG Zhen-zhong; MA Yuan; LI Zhi-yuan

    2004-01-01

    Based on large numbers of experiments, together with some theoretic support such as equations related to the experiment, thermodynamic principles and so on, one useful and reasonable self-protecting boron formulation is got to reinforce the muzzle shunt rail gun rail. The preliminary friction and abrasion test results show that the formulation is acceptable and the abrasion resistance of the steel rail enhances to some extent after the surface reinforcement.

  5. High abrasion resistance coating materials from organic/inorganic hybrid materials produced by the sol-gel method

    OpenAIRE

    1990-01-01

    A series of new high abrasion resistance coating materials have been prepared utilizing organic/inorganic hybrid materials formed by cohydrolyzing a metal alkoxide sol (e.g. silicon, aluminum, titanium, or zirconium metal alkoxide sol) with one or more bis(trialkoxysilane-containing) organic components or related functionalized species. These hybrid materials show optical clarity and improve the abrasion resistance of polymer substrates when applied as coatings and cured on such substrates.

  6. Cognitive vulnerability and dental fear

    Directory of Open Access Journals (Sweden)

    Spencer A John

    2008-01-01

    Full Text Available Abstract Background The Cognitive Vulnerability Model proposes that perceptions of certain characteristics of a situation are critical determinants of fear. Although the model is applicable to all animal, natural environment and situational fears, it has not yet been applied specifically to dental fear. This study therefore aimed to examine the association between dental fear and perceptions of dental visits as uncontrollable, unpredictable and dangerous. Methods The study used a clustered, stratified national sample of Australians aged 15 years and over. All participants were asked in a telephone interview survey to indicate their level of dental fear. Participants who received an oral examination were subsequently provided with a self-complete questionnaire in which they rated their perceptions of uncontrollability, unpredictability and dangerousness associated with dental visiting. Results 3937 participants were recruited. Each of the three vulnerability-related perceptions was strongly associated with the prevalence of high dental fear. In a logistic regression analysis, uncontrollability and dangerousness perceptions were significantly associated with high dental fear after controlling for age and sex. However, unpredictability perceptions did not have a statistically significant independent association with dental fear after controlling for all other variables. Conclusion Results are mostly consistent with the Cognitive Vulnerability Model of the etiology of fear, with perceptions of uncontrollability, unpredictability and dangerousness each showing a strong bivariate relationship with high dental fear prevalence. However, more extensive measures of vulnerability perceptions would be valuable in future investigations.

  7. Medical emergencies in dental practice.

    LENUS (Irish Health Repository)

    Wilson, M H

    2009-06-01

    Serious medical emergencies are fortunately a rare occurrence in the dental practice environment; however, if an emergency situation is encountered a delay in treatment may result in potentially avoidable consequences. The risk of mortality or serious morbidity can be reduced by ensuring that basic emergency equipment and medications are in place, and that the dental team is appropriately trained in basic life support measures. This article aims to provide an overview of the basic emergency medications and equipment that should be present in dental practices, and to discuss specific responses to some of the more common adverse medical events that can present while providing dental treatment.

  8. Development and Testing of Abrasion Resistant Hard Coats For Polymer Film Reflectors: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Jorgensen, G.; Gee, R.; DiGrazia, M.

    2010-10-01

    Reflective polymer film technology can significantly reduce the cost of solar reflectors and installed Concentrated Solar Power (CSP) plants by both reduced material cost and lower weight. One challenge of polymer reflectors in the CSP environment pertains to contact cleaning methods typically used with glass mirrors. Such contact cleaning methods can scratch the surface of polymer reflectors and thereby reduce specular reflectance. ReflecTech, Inc. (a subsidiary of SkyFuel, Inc.) and the National Renewable Energy Laboratory (NREL) initiated a cooperative research and development agreement (CRADA) to devise and develop an abrasion resistant coating (ARC) suitable for deposition onto polymer based mirror film. A number of candidate ARC products were identified as candidate formulations. Industrial collaborators prepared samples having their ARCs deposited onto ReflecTech Mirror Film pre-laminated to aluminum sheet substrates. Samples were provided for evaluation and subjected to baseline (unweathered) and accelerated exposure conditions and subsequently characterized for abrasion resistance and adhesion. An advanced ARC product has been identified that exhibits outstanding initial abrasion resistance and adhesion to ReflecTech Mirror Film. These properties were also retained after exposure to the various accelerated stress conditions. This material has been successfully manufactured as a 1.5 m wide roll-to-roll construction in a production environment.

  9. An investigation on surface roughness of granite machined by abrasive waterjet

    Indian Academy of Sciences (India)

    Gokhan Aydin; Izzet Karakurt; Kerim Aydiner

    2011-07-01

    Abrasive waterjet (AWJ) cutting is an emerging technology which enables the shaping of practically all engineering materials. However, AWJ cutting may cause roughness and waviness on the cut surface. This significantly affects the dimensional accuracy of the machined part and the quality of surface finish. In this study, the surface roughness of three granites is experimentally investigated for varying process parameters in abrasive waterjet. The philosophy of the Taguchi design is followed in the experimental study. Effects of the control (process) factors on the surface roughness are presented in terms of the mean of means responses. Additionally, the data obtained are evaluated statistically using the analysis of variance (ANOVA) to determine significant process parameters affecting the surface roughness. Furthermore, effects of the material properties on the surface roughness are assessed. It was statistically found that the water pressure and the abrasive flow rate are the most significant factors influencing the surface roughness of granites. Additionally, a consistent relationship between the material grain size and surface roughness of the granites was observed.

  10. Ergonomics of abrasive blasting: a comparison of high pressure water and steel shot.

    Science.gov (United States)

    Rosenberg, Beth; Yuan, Lu; Fulmer, Scott

    2006-09-01

    Abrasive blasting with silica sand has long been associated with silicosis. Alternatives to sand are being used increasingly. While NIOSH has done extensive investigations of the respiratory effects of the substitutes for sand, the ergonomic effects of the substitutes have not been examined. Too often, hazards are shifted, and technologies that might save workers' lungs could do so at the expense of their musculoskeletal systems. Hence, the objective of this study was to examine the ergonomic effects of alternatives to sand. Multiple methods, both qualitative and quantitative, were used to yield numerous kinds of data for the analysis of exposures to abrasive blasters. PATH, a method for quantifying ergonomic exposure in non-routine work, was combined with interviews with workers, biomechanical modeling and noise level readings to assess the ergonomics of two abrasive blasting operations: high-pressure water and steel shot. Advantages and disadvantages of each medium are discussed. High-pressure water was slightly less ergonomically stressful, environmentally cleaner, much quieter and less dusty that steel shot, and it was reported to be slower on those tasks where both media could be used.

  11. Effect of Pearlite Interlamellar Spacing on Predominant Abrasive Wear Mechanism of Fully Pearlitic Steel

    Institute of Scientific and Technical Information of China (English)

    J.Ahmadi; M.Monirvaghefi; M.Salehi; B.Niroumand

    2004-01-01

    The aim of this investigation was the determination of the predominant wear mechanism an three-body abrasion of fully pearlitic low ahoy steel. Furthermore. the effect of pearlite interlamellar spacing on wear behavior was investigated, For this purpase, the samples were subjected to the different heat treating to artainthg different interlamellar spacing. Mechanical properties such as hardness, yield strength, tensile strength, elongation, and impact toughness were evaluated. Three body abrasion tests were conducted under ASTM standard condition using a rubber wheel abrasion test apparatus. Abraded surface and wear debris were investigated by light optical microscopy and scanning electron microscopy. The results showed that wear resistance of fully pearlitic steel depended to pearlite interlamellar spacing the and lower spacing has the greater wear realstance, so it may be due to subsurface work hardening and interlamellar spacing and cernentite in fine and/or coarse pearlite, thai influence on surface destruction during wear. Although during wear process the several mechanisms play roles, but study of surface and debris shows that with decreasing interlamellar spacing, the predominant mechanism wear changed front ploughing to cuttthg mode.

  12. Effect of abrasive surface roughening on the secondary yield of various metals

    Science.gov (United States)

    Graves, Timothy

    2007-11-01

    The secondary electron yield of metallic conductors plays a critical role in the development of multipactor discharges. These discharges require a secondary yield greater than unity at the appropriate energy level for sustained breakdown. By reducing the secondary yield below unity in the necessary energy range, multipactor and multipactor-induced glow discharges can be eliminated. Surface roughening has been shown to successfully lower the secondary yield to below unity (ref. 1). In addition, abrasive bead blasting has been shown to effectively reduce the secondary yield of copper surfaces while preserving voltage breakdown characteristics (ref. 2). This study investigates the effect of abrasive surface roughening on the secondary yield of materials such as copper, aluminum, and stainless steel. In addition to measuring the change in the secondary yield as a function of abrasive particle size, the multipactor resistance and voltage breakdown characteristics are investigated. In addition, the effect of vacuum conditioning via multipactor and rf plasma cleaning on the roughened surfaces will be discussed. Ref. 1. H. Bruining. Physics and Applications of Secondary Electron Emission. McGraw-Hill, NY, 1954. Ref. 2. T. P. Graves, Ph.D. Thesis, MIT. 2007

  13. Effect of Pearlite Interlamellar Spacing on Predominant Abrasive Wear Mechanism of Fully Pearlitic Steel

    Institute of Scientific and Technical Information of China (English)

    J. Ahmadi; M. Monirvaghefi; M. Salehi; B. Niroumand

    2004-01-01

    The aim of this investigation was the determination of the predominant wear mechanism on three-body abrasion of fully pearlitic low alloy steel. Furthermore, the effect of pearlite interlamellar spacing on wear behavior was investigated.For this purpose, the samples were subjected to the different heat treating to attaining different interlamellar spacing.Mechanical properties such as hardness, yield strength, tensile strength, elongation, and impact toughness were evaluated.Three body abrasion tests were conducted under ASTM standard condition using a rubber wheel abrasion test apparatus.Abraded surface and wear debris were investigated by light optical microscopy and scanning electron microscopy.The results showed that wear resistance of fully pearlitic steel depended to pearlite interlamellar spacing the and lower spacing has the greater wear resistance, so it may be due to subsurface work hardening and interlamellar spacing and cementite in fine and/or coarse pearlite, that influence on surface destruction during wear. Although during wear process the several mechanisms play roles, but study of surface and debris shows that with decreasing interlamellar spacing, the predominant mechanism wear changed from ploughing to cutting mode.

  14. Effects of hybrid composition of LCP and glass fibres on abrasive wear of reinforced LLDPE

    Indian Academy of Sciences (India)

    S A R Hashmi; Ajay Naik; Navin Chand

    2006-02-01

    The hybrid of liquid crystalline polymer (LCP) fibres and glass fibres (GF) provide a combination of modulus and toughness to semi-crystalline linear-low-density-polyethylene (LLDPE). LCP and GF fibres reinforced composites were studied using two-body abrasion tester under different applied loads. Two sets of fibre reinforced LLDPE, 10 and 20 vol%, were investigated. The contents of LCP and glass fibres were varied as 25, 50, 75 and 100 vol% of overall volume of fibres in LLDPE. The effect of replacing glass fibre with LCP fibre on wear is reported. Wear loss increased with the applied loads and glass fibre contents in LLDPE. The replacements of glass fibres with LCP fibres improved abrasive wear resistance of composite. The composite containing 20 vol% of glass fibres in LLDPE showed the specific wear rate nearly double to that of LCP fibre reinforced LLDPE. Incorporation of LCP fibre improved wear resistance of glass fibre reinforced LLDPE. Worn surfaces were studied using SEM. Glass fibres were broken in small debris and removed easily whereas LCP fibres yielded to fibrillation during abrasive action. The overall wear rate was governed by the composition and test conditions.

  15. Mechanical and Abrasive Wear Properties of Anodic Oxide Layers Formed on Aluminium

    Institute of Scientific and Technical Information of China (English)

    W.Bensalah; K.Elleuch; M.Feki; M.Wery; H.F.Ayedi

    2009-01-01

    Aluminium oxide coatings were formed on aluminium substrates in oxalic acid-sulphuric acid bath. Abrasion tests of the obtained anodic layers were carried out on a pin-on-disc machine in accordance with the ISO/DP 825 specifications. The Vickers microhardness, D (HV0.2). and the abrasion weight loss, Wa (mg) were measured. Influence of oxalic acid concentration (Cox), bath temperature (T) and anodic current density (J) on D and Wa has been examined, and the sulphuric acid concentration (Caul) was maintained at 160 g.L-1. It was found that high microhardness and abrasive wear resistance of oxide layers were produced under low temperatures and high current densities with the addition of oxalic acid. The morphology and the composition of the anodic oxide layer were examined by scanning electron microscopy (SEM), atomic force microscopy (AFM), optical microscopy and glow-discharge optical emission spectroscopy (GDOES). It was found that the chemistry of the anodizing electrolyte, temperature, and current density are the controlling factors of the mechanical properties of the anodic oxide layer.

  16. Experimental Study on Layered Ice Bonded Abrasive Polishing of Glass-ceramics

    Directory of Open Access Journals (Sweden)

    Yuli SUN

    2014-12-01

    Full Text Available Layered ice bonded abrasive tools (LIBAT is a new kind of one which not only has the ability of lapping and polishing but also has the effect of self-dressing. In this paper, two kinds of layered ice bonded abrasive tools were designed and manufactured. Experimental studies on layered ice bonded abrasive (LIBA polishing of glass-ceramics were conducted. The results show that the surface topography of glass-ceramics polished by micro α-Al2O3-nano α-Al2O3 LIBAT is better than that of polished by micro α-Al2O3-nano SiO2 LIBAT. The surface roughness Sa of glass-ceramics polished by the two kinds of LIBAT is at the nanometer scale. The reasons of this phenomenon were analyzed. The experimental results illustrate that the LIBAT shows good effect and can be used in production practice. DOI: http://dx.doi.org/10.5755/j01.ms.20.4.6149

  17. Microstructure and Abrasive Wear Performance of Ni-Wc Composite Microwave Clad

    Science.gov (United States)

    Bansal, Amit; Zafar, Sunny; Sharma, Apurbba Kumar

    2015-10-01

    In the present work, Ni-WC powder was deposited on mild steel substrate to develop clads through microwave hybrid heating technique. The cladding trials were carried out in an industrial microwave applicator at 1.1 kW for 540 s. The Ni-WC composite clads were characterized for microstructure and abrasive wear performance through combination of x-ray diffraction, electron and optical microscopy, microhardness, and wear tests. Phase analysis of the Ni-WC clad indicated the presence of stable carbides such as WC, W2C, Ni2W4C, and Fe6W6C. The microstructure study of the clad layer revealed the presence of a uniformly distributed interlocked WC-based reinforcement embedded in the Ni-based matrix. The average Vicker's microhardness in the clad layer was observed to be 1028 ± 90 HV, which was approximately three times the microhardness of the substrate. Abrasive wear resistance of the microwave clads was superior to the MS substrate. Abrasion was the main wear mechanism in the Ni-WC clads and the substrate samples. However, the presence of WC-based reinforcement in the composite clads reduced microcutting, resulting in enhanced wear resistance.

  18. The surface quality of AWJ cut parts as a function of abrasive material reusing rate

    Science.gov (United States)

    Schnakovszky, C.; Herghelegiu, E.; Radu, M. C.; Tampu, N. C.

    2015-11-01

    Abrasive water jet cutting (AWJ) has been extensively used during the last years to process a large variety of materials since it offers important advantages as a good quality of the processed surface, without heat affected zones, low environmental impact (no emission of dust or other compounds that endanger the health of the user), small induced mechanical stresses etc. The main disadvantage is the high cost of processing (cost of equipment and consumables). In view of this, the effects of reusing the abrasive material on the quality of processed surface are investigated in this paper. Two steel materials were used: OL 37 (S 235) with large applicability in machine building industry and 2P armor steel used in the arms industry. The reusing rate of the garnet abrasive material was: 0%, 20%, 40%, 60%, 80% and 100%. The quality of processed surface was quantified by the following parameters: width at the jet inlet (Li), width at the jet outlet (Lo), inclination angle (α), deviation from perpendicularity (u) and roughness (Ra).

  19. Rock Cutting Depth Model Based on Kinetic Energy of Abrasive Waterjet

    Science.gov (United States)

    Oh, Tae-Min; Cho, Gye-Chun

    2016-03-01

    Abrasive waterjets are widely used in the fields of civil and mechanical engineering for cutting a great variety of hard materials including rocks, metals, and other materials. Cutting depth is an important index to estimate operating time and cost, but it is very difficult to predict because there are a number of influential variables (e.g., energy, geometry, material, and nozzle system parameters). In this study, the cutting depth is correlated to the maximum kinetic energy expressed in terms of energy (i.e., water pressure, water flow rate, abrasive feed rate, and traverse speed), geometry (i.e., standoff distance), material (i.e., α and β), and nozzle system parameters (i.e., nozzle size, shape, and jet diffusion level). The maximum kinetic energy cutting depth model is verified with experimental test data that are obtained using one type of hard granite specimen for various parameters. The results show a unique curve for a specific rock type in a power function between cutting depth and maximum kinetic energy. The cutting depth model developed here can be very useful for estimating the process time when cutting rock using an abrasive waterjet.

  20. Rapid manufacturing of SiC molds with micro-sized holes using abrasive water jet

    Institute of Scientific and Technical Information of China (English)

    Bo-Sung SHIN; Kang-Su PARK; Yeon-Kyoung BAHK; Sun-Ki PARK; Jung-Han LEE; Jeung-Sang GO; Myung-Chang KANG; Chae-Moon LEE

    2009-01-01

    Silicon carbide (SIC) is highly wear resistant with good mechanical properties, including high temperature strength, excellent chemical resistance, and high thermal conductivity and thermal shock resistance. SiC molds, which can be produced with diverse microstructural features, are now widely used in glass molding owing to their excellent characteristics, and also have potential applicability in IT industries. SiC molds are traditionally fabricated by silicon micromachining or dicing. The fabrication cost of silicon micromachining is very high, however, because several expensive masks are needed. Furthermore, the fabrication time is very long. Meanwhile, it is difficult to make micro-patterned molds with arbitrary shapes using dicing saws. Abrasive water jet (AWJ) is widely applied to cut and drill very brittle, soft and fibrous materials. It offers high energy density, the absence of a heat affected zone(HAZ), high performance, and an environment friendly process. In spite of these advantages, micro-hole drilling via conventional AWJ processing suffers from notable shortcomings. We proposed a new abrasive supplying method of AWJ. The proposed method reduces frosting phenomena, and provides micro-machining of AWJ. The characteristics of a hole machined was investigated by the proposed AWJ process according to the ratio of water and abrasives. With the optimal experimental conditions, 3 × 3 array SiC molds with the diameter of 700 μm and depth of 900 μm were successfully manufactured.

  1. Wear characteristics of second-phase-reinforced sol-gel corundum abrasives

    Energy Technology Data Exchange (ETDEWEB)

    Mayer, Joachim [Central Facility for Electron Microscopy (GFE), RWTH Aachen University, 52056 Aachen (Germany)]. E-mail: mayer@gfe.rwth-aachen.de; Engelhorn, Robert [Laboratory for Machine Tools and Production Engineering (WZL), RWTH Aachen University, 52056 Aachen (Germany); Bot, Rosemarie [Laboratory for Machine Tools and Production Engineering (WZL), RWTH Aachen University, 52056 Aachen (Germany); Weirich, Thomas [Central Facility for Electron Microscopy (GFE), RWTH Aachen University, 52056 Aachen (Germany); Herwartz, Cleo [Central Facility for Electron Microscopy (GFE), RWTH Aachen University, 52056 Aachen (Germany); Klocke, Fritz [Laboratory for Machine Tools and Production Engineering (WZL), RWTH Aachen University, 52056 Aachen (Germany)

    2006-08-15

    The use of sol-gel technologies makes it possible to manufacture new corundum-based abrasives with superior performance in terms of grinding processes. The aim of the present work is to reveal the detailed wear mechanisms on a nanometre scale and relate them to the particular microstructure of these new materials. A commercial sol-gel corundum (Cubitron 321{sup TM}) was used. In the grinding experiments, wheels consisting of four different mixtures with 0%, 30%, 50% and 100% of sol-gel corundum were used to machine a tool steel (100Cr6V) by plane grinding. Changes to the contact zone were studied after controlled abrasion experiments on hard steel substrates using a pin-on-wheel tribometer, in single grit scratch tests and after tests of resistance to heat shock. Cross-sections through contact areas of a sol-gel grain were prepared using a focused ion beam workstation and investigated using conventional and analytical transmission electron microscopy. The results indicate that the combined effect of controlled propagation of subsurface shear cracks and plastic deformation leads to the formation of flat contact zones. On these contact zones, a nanocrystalline FeO debris layer adheres to the alumina. The results of our investigations were verified in grinding experiments and give insight into the physical reasons of the superior tribological properties of the sol-gel corundum abrasives.

  2. Improved Soft Abrasive Flow Finishing Method Based on Turbulent Kinetic Energy Enhancing

    Science.gov (United States)

    LI, Jun; JI, Shiming; TAN, Dapeng

    2017-03-01

    Soft abrasive flow(SAF) finishing can process the irregular geometric surfaces, but with the matter of low processing efficiency. To address the issue, an improved SAF finishing method based on turbulent kinetic energy enhancing is proposed. A constrained flow passage with serration cross-section is constructed to increase the turbulence intensity. Taking the constrained flow passage as the objective, a two-phase fluid dynamic model is set up by using particle trajectory model and standard k-ɛ turbulence model, and the flow field characteristics of the flow passage are acquired. The numerical results show that the serration flow passage can enhance the turbulence intensity, uniform the particles distribution, and increase the particle concentration near the bottom wall. The observation results by particle image velocimetry(PIV) show that the internal vortex structures are formed in flow passage, and the abrasive flow takes on turbulence concentrating phenomenon in near-wall region. The finishing experiments prove that the proposed method can obtain better surface uniformity, and the processing efficiency can be improved more 35%. This research provides an abrasive flow modeling method to reveal the particle motion regulars, and can offer references to the technical optimization of fluid-based precision processing.

  3. Portable mixed abrasive water jet equipment for rescue in high gas mine shaft

    Institute of Scientific and Technical Information of China (English)

    ZENG Rui; DU Chang-long; XU Rui; ZHAO Jing

    2011-01-01

    In order to rescue a trapped miner and clean out roadways quickly in a high gas mine shaft after a mining mishap, a special portable cold-cutting equipment is needed, the main technology parameters were calculated according to the advanced cold-cutting technology of high pressure abrasive water jet and the portable mixed abrasive water jet equipment (PAWE) was designed to meet the needs of emergency rescue in high gas mine shafts. Tested the PAWE in a high gas environment, and the result shows that the maximum cutting depth of solid iron pipe is 18 mm and the recoilforce of the sprayer is 28.9 N under the conditions that actual cutting pressure is 29 MPa, starting target distance is 10 mm, cutting speed is 180 mm/min and concentration of abrasive is 32%. The course of the experiment in the high gas environment was smooth and continuous, without any explosion. The PAWE is easy to move and operate, but the nozzle which was worn badly in the sprayer should be changed every 8 minutes.

  4. Modeling of Tool Wear in Vibration Assisted Nano Impact-Machining by Loose Abrasives

    Directory of Open Access Journals (Sweden)

    Sagil James

    2014-01-01

    Full Text Available Vibration assisted nano impact-machining by loose abrasives (VANILA is a novel nanomachining process that combines the principles of vibration assisted abrasive machining and tip-based nanomachining, to perform target specific nanoabrasive machining of hard and brittle materials. An atomic force microscope (AFM is used as a platform in this process wherein nanoabrasives, injected in slurry between the workpiece and the vibrating AFM probe which is the tool, impact the workpiece and cause nanoscale material removal. The VANILA process are conducted such that the tool tip does not directly contact the workpiece. The level of precision and quality of the machined features in a nanomachining process is contingent on the tool wear which is inevitable. Initial experimental studies have demonstrated reduced tool wear in the VANILA process as compared to indentation process in which the tool directly contacts the workpiece surface. In this study, the tool wear rate during the VANILA process is analytically modeled considering impacts of abrasive grains on the tool tip surface. Experiments are conducted using several tools in order to validate the predictions of the theoretical model. It is seen that the model is capable of accurately predicting the tool wear rate within 10% deviation.

  5. INFLUENCE OF REFRACTORY FILLERS ON THE PROCESS OF COMPOSITE BRAZING OF DIAMOND-ABRASIVE TOOLS

    Directory of Open Access Journals (Sweden)

    Kozachenko A. D.

    2015-04-01

    Full Text Available Brazes with increased viscosity are needed for brazing of abrasive diamond tools with working surface of complex contoured shape. It’s known that high viscosity is a property of composite brazes consisting of fusible matrix and refractory filler that is not melting during brazing. Goal of the work is to research the influence of refractory fillers on the process of composite brazing of diamond-abrasive tools and on that basis discover the optimal composition of braze. Composite brazes Sn-Cu-Co were researched in the work. It is determined that at least 26-28% (by mass of cobalt powder should be included in brazes for giving the braze Sn-Cu-Co necessary viscosity and for creation of uniform diamond-comprising layers with thickness up to 2.5 mm on the vertical layers and sharp edges of tools. It is determined that solid-state sintering of powders on the initial stage of heating the composite braze leads to emerging of internal stresses and forming cracks. Inert additions that prevent solid-state sintering should be include in braze to prevent cracking. Optimal inert addition for brazes Sn-Cu-Co is the tungsten powder. Minimum content of tungsten needed to prevent cracking is 6% (by mass. Optimal content of components in composition braze for brazing shaped diamond-abrasive tools is (% by mass: 30 Co, 20 Sn, 43 Cu, 7 W

  6. Coupling behavior between adhesive and abrasive wear mechanism of aero-hydraulic spool valves

    Institute of Scientific and Technical Information of China (English)

    Chen Yunxia; Gong Wenjun; Kang Rui

    2016-01-01

    Leakage due to wear is one of the main failure modes of aero-hydraulic spool valves. This paper established a practical coupling wear model for aero-hydraulic spool valves based on dynamic system modelling theory. Firstly, the experiment for wear mechanism verification proved that adhesive wear and abrasive wear did coexist during the working process of spool valves. Sec-ondly coupling behavior of each wear mechanism was characterized by analyzing actual time-variation of model parameters during wear evolution process. Meanwhile, Archard model and three-body abrasive wear model were utilized for adhesive wear and abrasive wear, respectively. Furthermore, their coupling wear model was established by calculating the actual wear volume. Finally, from the result of formal test, all the required parameters for our model were obtained. The relative error between model prediction and data of pre-test was also presented to verify the accuracy of model, which demonstrated that our model was useful for providing accurate prediction of spool valve’s wear life.

  7. Innovation of dental education system for researcher, dentist, dental hygienist and dental technician in Hiroshima University

    OpenAIRE

    Kurihara, Hidemi

    2006-01-01

    Hiroshima University Faculty of Dentistry's goal is to become the worldwide research and education center in Dentistry. It seems to constitute the dental education by two missions: core and characteristic. Hiroshima University Faculty of Dentistry has clarified their characteristic mission and improved dental education system to reinforce the innovative part of the education. We started two programs to cultivate researchers/educators who will be a world-wide leader of dental research and educ...

  8. Mandatory Clinical Practice for Dental and Dental Hygiene Faculty.

    Science.gov (United States)

    Cameron, Cheryl A.; And Others

    1982-01-01

    Dental and dental hygiene faculty should maintain their clinical skills through regular practice, to improve their ability to relate to students through instruction, provide an additional source of income, and improve their image in the community. Institutional policies fostering and regulating faculty practice plans are suggested. (Author/MSE)

  9. The Swedish national dental insurance and dental health care policy

    DEFF Research Database (Denmark)

    Moore, Rod

    1981-01-01

    Sweden initiated a dental health care insurance in 1973. The health insurance is outlined, current problems and political issues are described. The benefits and limitations are described.......Sweden initiated a dental health care insurance in 1973. The health insurance is outlined, current problems and political issues are described. The benefits and limitations are described....

  10. Dosimetric analysis of SMD phototransistor in dental phantom of different geometries

    Energy Technology Data Exchange (ETDEWEB)

    Belinato, W.; Magalhaes, C. M. S.; Souza, D. N. [Departmento de Fisica, Universidade Federal de Sergipe, Av. Marechal Rondon s/n, 49.100-000, Rosa Elze, Sao Cristovao-SE (Brazil); Santos, L. A. P. [Laboratorio de Instrumentacao Nuclear, Centro Regional de Ciencias Nucleares, Av. Professor Luiz Freire, 200, 50-740-540, Recife-PE (Brazil)

    2009-10-15

    A commercial surface mount device (SMD) phototransistor, OP520, was inserted in two dental phantoms for dosimetric analysis. The irradiations were accomplished in a dental x-ray equipment of 80 kV using different exposition times. A standard ionization chamber was irradiated at the same conditions and the air kerma measured with it was compared with the electrical charge evaluated by the phototransistor. The results showed satisfactory correspondence among the detectors readings. Moreover, the phototransistor showed up quite sensitively for dental applications, allowing verifying the variations for the different phantoms configurations. (Author)

  11. Dental erosion in workers exposed to sulfuric acid in lead storage battery manufacturing facility.

    Science.gov (United States)

    Suyama, Yuji; Takaku, Satoru; Okawa, Yoshikazu; Matsukubo, Takashi

    2010-01-01

    Dental erosion, and specifically its symptoms, has long been studied in Japan as an occupational dental disease. However, in recent years, few studies have investigated the development of this disease or labor hygiene management aimed at its prevention. As a result, interest in dental erosion is comparatively low, even among dental professionals. Our investigation at a lead storage battery factory in 1991 found that the work environmental sulfuric acid density was above the tolerable range (1.0mg/m(3)) and that longterm workers had dental erosion. Therefore, workers handling sulfuric acid were given an oral examination and rates of dental erosion by tooth type, rates of erosion by number of working years and rates of erosion by sulfuric acid density in the work environment investigated. Where dental erosion was diagnosed, degree of erosion was identified according to a diagnostic criterion. No development of dental erosion was detected in the maxillary teeth, and erosion was concentrated in the anterior mandibular teeth. Its prevalence was as high as 20%. Rates of dental erosion rose precipitously after 10 working years. The percentages of workers with dental erosion were 42.9% for 10-14 years, 57.1% for 15-19 years and 66.7% for over 20 years with 22.5% for total number of workers. The percentages of workers with dental erosion rose in proportion to work environmental sulfuric acid density: 17.9% at 0.5-1.0, 25.0% at 1.0-4.0 and 50.0% at 4.0-8.0mg/m(3). This suggests that it is necessary to evaluate not only years of exposure to sulfuric acid but also sulfuric acid density in the air in factory workers.

  12. Dental Chairside Technique. Student's Manual.

    Science.gov (United States)

    Apfel, Maura; Weaver, Trudy Karlene

    This manual is part of a series dealing with skills and information needed by students in dental assisting. The individualized student materials are suitable for classroom, laboratory, or cooperative training programs. This student manual contains four units covering the following topics: local anesthesia; dental office emergencies; oral hygiene;…

  13. Dentistry and Dental Hygiene Handbook.

    Science.gov (United States)

    New York State Education Dept., Albany. Office of the Professions.

    A reference guide to laws, rules, and regulations that govern dentistry and dental hygiene practice in New York State is presented. In addition to identifying licensing requirements/procedures for dentists and dental hygienists, general provisions of Title VIII of the Education Law are covered, along with state management, professional misconduct,…

  14. Dental problems in epileptic patients.

    Science.gov (United States)

    Zioło, Anna; Mielnik-Błaszczak, Maria

    2004-01-01

    On the grounds of literature and own clinical experience, pathological changes in epilepitic patients have been described. Dental management procedures in these patients have also been presented. The unquestionable importance of prophylaxis, which may markedly minimize the impact of epilepsy on the incidence of mouth diseases, has been emphasised. It has also been stated that epileptic patients should receive specialised and integrated dental treatment.

  15. Dentistry and Dental Hygiene Handbook.

    Science.gov (United States)

    New York State Education Dept., Albany. Office of the Professions.

    The handbook contains laws, rules, and regulations of the New York State Education Department that govern dentistry and dental hygiene practice in the state. It describes licensure requirements and includes complete application forms and instructions for obtaining license and first registration as a dentist and dental hygienist. Applicants are…

  16. SYSTEMIC DISORDERS AFFECTING DENTAL PATHOLOGY

    OpenAIRE

    Knezevic R. Milan; Andjelic S. Gordana; Knezevic M. Milena

    2014-01-01

    A retrospective overview of systemic disorders which might be associated with dental pathology is made. They are grouped as follows: (a) congenital dental developmental disorders, (b) chromosomal anomalies, (c) radiations, (d) immune disorders, (e) intoxications, (f) neurological alterations, (g) gastrointestinal diseases, (h) osteodystrophy and associated conditions, (i) skin diseases, (j) metabolic and endocrine disorders, (k) craniofacial malformation syndromes and other congenital g...

  17. Music interventions for dental anxiety.

    Science.gov (United States)

    Bradt, J; Teague, A

    2016-11-25

    Anxiety is a significant issue in the dental care of adults and children. Dental anxiety often leads to avoidance of dental care which may result in significant deterioration of oral and dental health. Non-pharmacological anxiety management interventions such as music listening are increasingly used in dental care. Although efficacy for music's anxiolytic effects has been established for pre-operative anxiety, findings regarding the use of music listening for dental anxiety are inconclusive, especially for children. The use of music for passive distraction may not be adequate for children and highly anxious adults. Instead, interventions offered by a trained music therapist may be needed to optimize music's anxiolytic impact. Music therapy interventions are individualized to the patient's presenting needs and geared at enhancing patients' active engagement in the management of their anxiety. Interventions may include (i) active refocusing of attention, (ii) music-guided deep breathing, (iii) music-assisted relaxation, and (iv) music-guided imagery. In addition, music therapists can teach patients music-based anxiety management skills prior to dental treatments, offer them the opportunity to express emotions related to the upcoming procedure, and help them gain a sense of control and safety. Clinical guidelines for the use of music listening by dental practitioners are offered.

  18. Competition and dental services.

    Science.gov (United States)

    Grytten, J; Sørensen, R

    2000-07-01

    Dental services for adults are different from all other Norwegian health services in that they are provided by private producers (dentists) who have full freedom to establish a practice. They have had this freedom since the end of World War II. A further liberalization of the market for dental services occurred in November 1995, when the so-called normal tariff was repealed. The system changed from a fixed fee system to a deregulated fee system. In principle, the market for dental services for adults operates as a free competitive market, in which dentists must compete for a market share. The aim of this study was to study the short-term effects of competition. A comprehensive set of data on fees, practice characteristics, treatment profiles and factors that dentists take into account when determining fees was analysed. The main finding was that competition has a weak effect. No support was found for the theory that the level of fees is the result of monopolistic competition or monopoly. The results also provided some evidence against the inducement hypothesis. At this stage, it is interesting to notice that dentists do not seem to exploit the power they have to control the market. One explanation, which is consistent with the more recent literature, is that physicians' behaviour to a large extent is influenced by professional norms and caring concerns about their patients. Financial incentives are important, but these incentives are constrained by norms other than self-interest. The interpretation of the results should also take into account that the deregulation has operated for a short time and that dentists and patients may not yet have adjusted to changes in the characteristics of the market.

  19. Dental Forensics: Bitemark Analysis

    Directory of Open Access Journals (Sweden)

    Elza Ibrahim Auerkari

    2013-06-01

    Full Text Available Forensic odontology (dental forensics can provide useful evidence in both criminal and civil cases, and therefore remains a part of the wider discipline of forensic science. As an example from the toolbox of forensic odontology, the practice and experience on bitemark analysis is reviewed here in brief. The principle of using visible bitemarks in crime victims or in other objects as evidence is fundamentally based on the observation that the detailed pattern of dental imprints tend to be practically unique for each individual. Therefore, finding such an imprint as a bitemark can bear a strong testimony that it was produced by the individual that has the matching dental pattern. However, the comparison of the observed bitemark and the suspected set of teeth will necessarily require human interpretation, and this is not infallible. Both technical challenges in the bitemarks and human errors in the interpretation are possible. To minimise such errors and to maximise the value of bitemark analysis, dedicated procedures and protocols have been developed, and the personnel taking care of the analysis need to be properly trained. In principle the action within the discipline should be conducted as in evidence-based dentristy, i.e. accepted procedures should have known error rates. Because of the involvement of human interpretation, even personal performance statistics may be required from legal expert statements. The requirements have been introduced largely due to cases where false convictions based on bitemark analysishave been overturned after DNA analysis.DOI: 10.14693/jdi.v15i2.76

  20. Nanotechnology for dental implants.

    Science.gov (United States)

    Tomsia, Antoni P; Lee, Janice S; Wegst, Ulrike G K; Saiz, Eduardo

    2013-01-01

    With the advent of nanotechnology, an opportunity exists for the engineering of new dental implant materials. Metallic dental implants have been successfully used for decades, but they have shortcomings related to osseointegration and mechanical properties that do not match those of bone. Absent the development of an entirely new class of materials, faster osseointegration of currently available dental implants can be accomplished by various surface modifications. To date, there is no consensus regarding the preferred method(s) of implant surface modification, and further development will be required before the ideal implant surface can be created, let alone become available for clinical use. Current approaches can generally be categorized into three areas: ceramic coatings, surface functionalization, and patterning on the micro- to nanoscale. The distinctions among these are imprecise, as some or all of these approaches can be combined to improve in vivo implant performance. These surface improvements have resulted in durable implants with a high percentage of success and long-term function. Nanotechnology has provided another set of opportunities for the manipulation of implant surfaces in its capacity to mimic the surface topography formed by extracellular matrix components of natural tissue. The possibilities introduced by nanotechnology now permit the tailoring of implant chemistry and structure with an unprecedented degree of control. For the first time, tools are available that can be used to manipulate the physicochemical environment and monitor key cellular events at the molecular level. These new tools and capabilities will result in faster bone formation, reduced healing time, and rapid recovery to function.

  1. Sensibilidad dentaria Dental sensibility

    OpenAIRE

    P. Tortolini

    2003-01-01

    La sensibilidad dentaria l es un problema común que se presenta entre el 9 y el 30% de la población adulta. La teoría hidrodinámica es aceptada como uno de los mecanismos de inducción de la respuesta pulpar dolorosa, debido a que los estímulos provocan el movimiento del fluido y para ello es necesario que la dentina este expuesta y que los túbulos dentinarios estén abiertos y permeables a la pulpa. Es fundamental realizar el diagnostico diferencial con otras causas de dolor dental e identific...

  2. The american dental dream.

    Science.gov (United States)

    Hodges, Nathan

    2015-01-01

    The American Dental Dream-the cultural desire for straight, white teeth-is difficult, if not impossible, for poor and working-class people to achieve. Using ethnographic fiction, autoethnography, poetry, and qualitative interviewing, I brush away the taken-for-granted assumptions about teeth. I explore the personal, relational, and structural consequences of this cultural desire, and show how social class writes itself on our bodies. I write these culture-centered teeth tales to show how one might cope with their teeth.

  3. Plaque Removal and Gingival Health after Use of a Novel Dental Gel: A Clinical Study

    Science.gov (United States)

    Nayudu, Anuradha; Lam, Tracie; Ho, Jessica; Forghany, Ali; Vu, Thinh; Ngo, William; Ajdaharian, Janet; Wilder-Smith, Petra

    2017-01-01

    Background Goal of this in vivo prospective, randomized, controlled, double-blinded, cross over study was to compare the level of plaque control and gingivitis after use of a novel dental gel (test) vs. A Triclosan/copolymer dentifrice (control). Methods After coronal polishing, 22 subjects with moderate gingivitis were randomly assigned to brush twice daily with test or control dentifrice for the first study Arm. Plaque, gingival and sulcus bleeding indices were recorded at baseline, week 2 and week 4. Professional coronal polishing was repeated, and then subjects brushed with the second dentifrice for 4 weeks. Clinical indices were again recorded at Baseline, week 2 and week 4. The effects of each dentifrice on clinical indices were compared using Student’s t-test. Results Brushing with the test gel produced significantly greater levels of plaque reduction versus the Triclosan/copolymer control dentifrice at each time point. 45% less plaque was measured after 4 weeks of test agent use than after control agent use (pTriclosan/Co-polymer dental gel. Practical Implications: A novel dental gel formulation that does not contain abrasives, detergents or antimicrobials may provide effective plaque control and support gingival health. PMID:28286702

  4. [Dental prostheses and dental impressions from a hygienic viewpoint].

    Science.gov (United States)

    Engelhardt, J P

    1986-12-01

    Dentures, dental impressions, removable orthodontic appliances and all dental technical devices, which are part of any dental treatment are parts as well of a potential crosscontamination chain in dental treatment. Most of those items do not tolerate heat as a sure sterilization medium. For disinfection, chemical disinfectant solutions may be used as far as they work properly and as they are tolerated by the materials in question. Though, one can report some progress in disinfection of dentures and impressions, there are still questions open depending on safety and/or compatibility of the particular materials. For disinfection of removable dentures chlorine-yielding preparations such as Maranon can be recommended. Peracid preparations, such as Sekusept, Sekusept steril and Dentavon may be useful for disinfection of dental impressions. To do the possible means to reduce the infection risk for all persons involved in the dental treatment, patient, dentist, dental technician and all auxiliary persons. This includes both, active hygiene provisions as sterilization and disinfection, as well as possible passive self protection.

  5. A Triservice Comparison of Dental Scaling Devices: Sonic and Ultrasonic

    Science.gov (United States)

    1989-05-01

    literature and contains a short history of the development of power scalers. It also contains a discus- sion of the relationship between dental scalers and...phenomenon caused by ultrasound. High intensity, alternating pressure waves passing through water at the tip of the scaler force air bub- bles in the...devices such as microwave ovens, electric shavers, electro- cautery, diathermy , vitalometers, and even electric toothbrushes have the potential to

  6. Dental photography today. Part 1: basic concepts

    Science.gov (United States)

    CASAGLIA, A.; DE DOMINICIS, P.; ARCURI, L.; GARGARI, M.; OTTRIA, L.

    2015-01-01

    SUMMARY This paper is the first article in a new series on digital dental photography. Part 1 defines the aims and objectives of dental photography for examination, diagnosis and treatment planning, legal and forensic documentation, publishing, education, marketing and communication with patients, dental team members, colleagues and dental laboratory. PMID:28042424

  7. Intergrated dental care in nursing homes

    NARCIS (Netherlands)

    Gerritsen, P.F.M.

    2015-01-01

    The thesis deals with integrated dental care in nursing homes. First, the dental treatment needs were ascertained of 432 residents in three Dutch nursing homes that offer integrated dental care. Dentist researchers intra-orally examined the residents and found that 72% required dental treatment. How

  8. 21 CFR 872.3275 - Dental cement.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dental cement. 872.3275 Section 872.3275 Food and... DENTAL DEVICES Prosthetic Devices § 872.3275 Dental cement. (a) Zinc oxide-eugenol—(1) Identification... filling or as a base cement to affix a temporary tooth filling, to affix dental devices such as crowns...

  9. 21 CFR 872.6390 - Dental floss.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dental floss. 872.6390 Section 872.6390 Food and... DENTAL DEVICES Miscellaneous Devices § 872.6390 Dental floss. (a) Identification. Dental floss is a... between the teeth to reduce tooth decay. The fibers of the device may be coated with wax for easier...

  10. Dental Therapy Assistant: Effect on Team Productivity.

    Science.gov (United States)

    Heid, Theodore H.

    The U.S. Army Dental Corps has implemented a formal program based on the concept that dental care can be more efficiently and effectively provided with treatment teams composed of one dental officer, two dental therapy assistants (DTAs), one basic assistant, and the shared support of other auxiliary personnel. Such a team will use three dental…

  11. 21 CFR 872.3700 - Dental mercury.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dental mercury. 872.3700 Section 872.3700 Food and... DENTAL DEVICES Prosthetic Devices § 872.3700 Dental mercury. (a) Identification. Dental mercury is a device composed of mercury intended for use as a component of amalgam alloy in the restoration of...

  12. Environmental Assessment: Proposed Consolidated Warehouse, Hill Air Force Base, Utah

    Science.gov (United States)

    2011-02-01

    pavements are identified, they would be properly handled during the demolition and construction process. Operational activities would generate the same...historic properties is extremely low . However, if any such properties are found during construction, ground-disturbing activities in the immediate...gas, and improve the capture of particulates during painting and abrasive blasting operations (in compliance with the base’s Title V air quality

  13. Developing core dental public health competencies for predoctoral dental and dental hygiene students.

    Science.gov (United States)

    Mascarenhas, Ana Karina; Atchison, Kathryn Ann

    2015-01-01

    Dental professionals are an "underutilized" workforce, when it comes to advocating for prevention and wellness in populations. The goal of this HRSA-funded project is to develop dental public health (DPH) competencies and curriculum for US predoctoral dental and dental hygiene programs. These competencies and accompanying curriculum are designed to better prepare the oral health workforce to meet the needs of the entire population, including the chronically underserved, those challenged by poor health literacy, or communities encountering barriers to accessing oral health care. By increasing the DPH competency of all graduating dental providers, in population-based approaches to preventing oral diseases rather than the existing exclusive focus on treatment, the number of providers who can respond to a population or the public's unmet needs and challenges, both in private practices and publicly supported clinics, will increase. This paper describes the competency development process and the eight competencies that were identified.

  14. [Dental anatomy of dogs].

    Science.gov (United States)

    Sarkisian, E G

    2014-12-01

    The aim of the research was to investigate dog teeth anatomy as animal model for study of etiopathogenesis of caries disease and physiological tooth wear in human. After examining the dog's dental system, following conclusions were drawn: the dog has 42 permanent teeth, which are distributed over the dental arches not equally, and so the upper dentition consists of 20, and the lower of 22 teeth. The largest are considered upper fourth premolar and lower first molars, which are called discordant teeth. Between discordant teeth and fangs a dog has an open bite, which is limited to the top and bottom conical crown premolar teeth. Thus, in the closed position of the jaws, behind this occlusion is limited by discordant teeth, just in contact are smaller in size two molars. Only large dog's molars in a valid comparison can be likened to human molars, which allows us to use them in an analog comparison between them with further study of the morphological features ensure durability short-crown teeth and their predisposition to caries.

  15. Exposure control practices for administering nitrous oxide: a survey of dentists, dental hygienists and dental assistants.

    Science.gov (United States)

    Boiano, James M; Steege, Andrea L; Sweeney, Marie H

    2016-12-12

    Engineering, administrative, and work practice controls have been recommended for many years to minimize exposure to nitrous oxide during dental procedures. To better understand the extent to which these exposure controls are used, the NIOSH Health and Safety Practices Survey of Healthcare Workers was conducted among members of professional practice organizations representing dentists, dental hygienists and dental assistants. The anonymous, modular, web-based survey was completed by 284 dental professionals in private practice who administered nitrous oxide to adult and/or pediatric patients in the seven days prior to the survey. Use of primary engineering controls [i.e., nasal scavenging mask and/or local exhaust ventilation (LEV) near the patient's mouth] was nearly universal, reported by 93% and 96% of respondents who administered to adult (A) and pediatric (P) patients, respectively. However, adherence to other recommended precautionary practices were lacking to varying degrees, and were essentially no different among those administering nitrous oxide to adult or pediatric patients. Examples of work practices which increase exposure risk, expressed as percent of respondents, included: not checking nitrous oxide equipment for leaks (41% A; 48% P); starting nitrous oxide gas flow before delivery mask or airway mask was applied to patient (13% A; 12% P); and not turning off nitrous oxide gas flow before turning off oxygen flow to the patient (8% A; 7% P). Absence of standard procedures to minimize worker exposure to nitrous oxide (13% of all respondents) and not being trained on safe handling and administration of nitrous oxide (3%) were examples of breaches of administrative controls which may also increase exposure risk. Successful management of nitrous oxide emissions should include properly fitted nasal scavenging masks, supplemental LEV (when nitrous oxide levels cannot be adequately controlled using nasal masks alone), adequate general ventilation, regular

  16. Dental coping strategies, general anxiety, and depression among adult patients with dental anxiety but with different dental-attendance patterns.

    Science.gov (United States)

    Bernson, Jenny M; Elfström, Magnus L; Hakeberg, Magnus

    2013-06-01

    The aim of the present study was to investigate dental coping strategies, general anxiety, and depression in relation to regularity of dental treatment among persons with either regular dental care or phobic avoidance, whilst controlling for sociodemographic factors. Psychometric questionnaires on dental anxiety, dental coping strategies, general anxiety, and depression were delivered to 263 adult patients with dental phobic avoidance behavior who were seeking help from a specialized dental fear clinic and to 141 adult patients with dental anxiety who were receiving regular dental care from various public dental clinics. The results showed that the levels of dental and general anxiety and of depression were significantly higher among irregular attendees compared with regular attendees. Irregular attendees admitted fewer adaptive coping strategies. Predictive of irregular dental care were gender, dental anxiety, general anxiety, and the nonuse of the coping strategy 'optimism'. This study further confirms earlier preliminary results that the use of optimistic thinking is predictive for regular dental attendance habits and that male gender is a risk factor for irregular attendance. Moreover, this study adds that a high level of general anxiety indicates a higher risk for irregular dental care.

  17. Study on ultra-precision magnetic abrasive finishing process using low frequency alternating magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Jinzhong, E-mail: wjz.0926@163.com; Zou, Yanhua, E-mail: yanhua@cc.utsunomiya-u.ac.jp; Sugiyama, Hitoshi, E-mail: sugiyama@cc.utsunomiya-u.ac.jp

    2015-07-15

    We proposed a new ultra-precision magnetic abrasive finishing (MAF) process using low frequency alternating magnetic field in this paper. Magnetic cluster themselves may produce the up and down movement change under alternating magnetic force. The movement may not only promote the dispersion of micro-magnetic particles, but also improve stirring effect and cross-cutting effects of the abrasives, achieving circulation and update to ensure the stability of grinding tools. This process is considered to be able to efficiently apply in ultra-precision finishing of plane and complicated micro-surfaces. In this study, we investigated the effects of alternating magnetic field on magnetic field distribution, finishing force and abrasive behavior. Furthermore, a set of experimental devices have been designed for finishing SUS304 stainless steel plate. The present work is aimed at understanding finishing particularity of this process and studying impacts of important process parameters namely grinding fluid, rotational speed of magnetic pole, current frequency on change in finish surface and material removal. Experimental results indicate that the process can realize ultra-precision finishing of plane by using oily grinding fluid. In the present research, the surface roughness of SUS304 stainless steel plate was improved from 240.24 nm to 4.38 nm by this process. - Highlights: • We investigated magnetic field distribution in processing region. • Magnetic cluster can produce a fluctuating finishing force in alternating magnetic field. • Oily grinding fluid is more applicable to this process. • Few nanometer finish surface can be obtained by this process.

  18. The unsteady nature of sea cliff retreat due to mechanical abrasion, failure and comminution feedbacks

    Science.gov (United States)

    Kline, Shaun W.; Adams, Peter N.; Limber, Patrick W.

    2014-08-01

    Sea cliff retreat is often linked to large waves, heavy precipitation and seismic events, but the specific operative mechanics have not been well constrained. In particular, what is the role of mechanical abrasion by beach sediments in cliff/platform evolution and how does it relate to the episodic nature of cliff retreat observed at certain locations? Here we present a simple, numerical model of sea cliff retreat that incorporates mechanical abrasion of a basal notch, threshold-controlled failure of the cantilevered block, and a feedback mechanism wherein retreat is dependent on the rate of sediment comminution within the surf zone. Using shore platform and cliff characteristics found in two coastal settings (the central California coast and the English North Sea coast), the model produces retreat rates comparable to those observed via field measurements. The highest retreat rates coincide with the steepest shore platforms and increasing wave height. Steeper platforms promote wave access to the cliff toe and, correspondingly, the receding cliff face produces additional accommodation space for the platform beach, preserving the erosive efficacy of the beach sediments. When exposed to energetic wave forcing, the slope of the inner platform segment controls retreat rates for concave platforms, whereas the slope of the outer platform segment exerts greater control for convex platforms. Platform beaches approached a long-term dynamic equilibrium on the concave profiles, leading to more consistent and steady retreat. Platform beaches were ephemeral on convex profiles, mirroring observed sand wave (Ord) migration on the Holderness coast, UK. These findings agree with previous field observations and support mechanical abrasion as a viable cause of temporal heterogeneity in cliff retreat rate for both coastlines.

  19. Standardization of a Volumetric Displacement Measurement for Two-Body Abrasion Scratch Test Data Analysis

    Science.gov (United States)

    Street, K. W. Jr.; Kobrick, R. L.; Klaus, D. M.

    2011-01-01

    A limitation has been identified in the existing test standards used for making controlled, two-body abrasion scratch measurements based solely on the width of the resultant score on the surface of the material. A new, more robust method is proposed for analyzing a surface scratch that takes into account the full three-dimensional profile of the displaced material. To accomplish this, a set of four volume- displacement metrics was systematically defined by normalizing the overall surface profile to denote statistically the area of relevance, termed the Zone of Interaction. From this baseline, depth of the trough and height of the plowed material are factored into the overall deformation assessment. Proof-of-concept data were collected and analyzed to demonstrate the performance of this proposed methodology. This technique takes advantage of advanced imaging capabilities that allow resolution of the scratched surface to be quantified in greater detail than was previously achievable. When reviewing existing data analysis techniques for conducting two-body abrasive scratch tests, it was found that the ASTM International Standard G 171 specified a generic metric based only on visually determined scratch width as a way to compare abraded materials. A limitation to this method was identified in that the scratch width is based on optical surface measurements, manually defined by approximating the boundaries, but does not consider the three-dimensional volume of material that was displaced. With large, potentially irregular deformations occurring on softer materials, it becomes unclear where to systematically determine the scratch width. Specifically, surface scratches on different samples may look the same from a top view, resulting in an identical scratch width measurement, but may vary in actual penetration depth and/or plowing deformation. Therefore, two different scratch profiles would be measured as having identical abrasion properties, although they differ

  20. ADVANCED 3D LASER MICROSCOPY FOR MEASUREMENTS AND ANALYSIS OF VITRIFIED BONDED ABRASIVE TOOLS

    Directory of Open Access Journals (Sweden)

    WOJCIECH KAPLONEK

    2012-12-01

    Full Text Available In many applications, when a precise non-contact assessment of an abrasive tools’ surface is required, alternative measurement methods are often used. Their use offers numerous advantages (referential method as they introduce new qualities into routinely realized measurements. Over the past few years there has been a dynamic increase in the interest for using new types of classical confocal microscopy. These new types are often defined as 3D laser microscopy. This paper presents select aspects of one such method’s application – confocal laser scanning microscopy – for diagnostic analysis of abrasive tools. In addition this paper also looks at the basis for operation, the origins and the development of this measurement technique.The experimental part of this paper presents the select results of tests carried out on grinding wheel active surfaces with sintered microcrystalline corundum grains SG™ bound with glass-crystalline bond. The 3D laser measuring microscopes LEXT OLS3100 and LEXT OLS4000 by Olympus were used in the experiments. Analysis of the obtained measurement data was carried out in dedicated OLS 5.0.9 and OLS4100 2.1 programs, supported by specialist TalyMap Platinum 5.0 software. The realized experiments confirmed the possibility of using the offered measurement method. This concerns both the assessment of grinding wheel active surfaces and their defects, as well as the internal structures of the tools (grain-bond connections. The method presented is an interesting alternative to the typical methods used in the diagnostics of abrasive tools.