WorldWideScience

Sample records for aerated flows analytical

  1. EMERGENCE ANGLE OF FLOW OVER AN AERATOR

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Aerator is an important device for release works of hydraulic structures with high-speed flow in order to protect them from cavitation damage. This kind of protecting effect is related closely to cavity length below the aerator, while the cavity length is dominated by the emergence angle over the aerator. Therefore it is crucial to determine this angle accurately. In the present paper the affecting intensities of flow depth and the fluctuating velocity on this angle were analyzed through two introduced parameters. Furthermore, the improved expressions of emergence angle estimation, for both ramp-type and step-type aerators, were presented by means of 68 sets of experimental data from 6 projects based on error theory. The results showed that the present method has higher accuracy than the previously reported methods.

  2. FLOW REGIMES BELOW AERATORS FOR DISCHARGE TUNNELS

    Institute of Scientific and Technical Information of China (English)

    MA Fei; WU Jian-hua

    2012-01-01

    The flow regimes below an aerator influence directly the air entrainment and the cavitation damage control.Based on the theoretical considerations,the experiments of the aerator for a discharge tunnel were conducted,and the relationships between the flow regime and hydraulic and geometric parameters were investigated.The results showed that,there are two kinds of threshold values for the flow regime conversions.One is Fr1-2 standing for the conversion from the fully filled cavity to the partially filled cavity,and the other is Fr2-3 which shows the change from the partially filled cavity to the net air cavity.Two empirical expressions were obtained for the conversions of the flow regimes,which can be used in the designs of the aerators.

  3. AERATION OF THE ICE-COVERED WATER POOLS USING THE WAVE FLOW AERATOR

    Directory of Open Access Journals (Sweden)

    Solomin E.E

    2013-12-01

    Full Text Available This article describes the technical advantages and economic benefits of the ice-covered pool aeration plants consuming power from renewable energy sources. We made a comparative evaluation of the wave flow-aeration method and other methods of pool aeration. We showed the indexes and the characteristics of the wave flow-maker for aeration of ice-covered pools on the territory of Russia. We also made calculations of the economic benefits of aeration plants using the devices converting renewable energy. The project can be scaled and extended to the territory of the CIS, Europe, USA and Canada in the changing climate conditions and the variety of feed reservoirs around the world.

  4. Two-phase flow simulation of aeration on stepped spillway

    Institute of Scientific and Technical Information of China (English)

    CHENG Xiangju; LUO Lin; ZHAO Wenqian; LI Ran

    2004-01-01

    Stepped spillways have existed as escape works for a very long time. It is found that water can trap a lot of air when passing through steps and then increasing oxygen content in water body, so stepped spillways can be used as a measure of re-aeration and to improve water quality of water body. However, there is no reliable theoretical method on quantitative calculation of re-aeration ability for the stepped spillways. By introducing an air-water two-phase flow model, this paper used k-ε turbulence model to calculate the characteristic variables of free-surface aeration on stepped spillway. The calculated results fit with the experimental results well. It supports that the numerical modeling method is reasonable and offers firm foundation on calculating re-aeration ability of stepped spillways. The simulation approach can provide a possible optimization tool for designing stepped spillways of more efficient aeration capability.

  5. RE-AERATION LAW OF WATER FLOW OVER SPILLWAYS

    Institute of Scientific and Technical Information of China (English)

    CHENG Xiang-ju; LUO Lin; CHEN Yong-can; ZHAO Wen-qian

    2006-01-01

    In order to explore the re-aeration law of water flow over spillway, the transfer process of oxygen in water flow over spillway was studied. The interfacial mass transfer coefficients were obtained by experiments. The flow fields and the turbulence characteristics are simulated by numerical methods. The fractional volume of fluid model (VOF) of the air-water two phase flows was introduced to track the interface. Consequently, the quantitative expression of the interfacial mass transfer coefficients related with velocity and kinetic energy at the free surface was derived and the re-aeration model for the water flow over spillway was established. The examination with the experimental data of different conditions shows the validity of the re-aeration model for the water flow over spillways. This study will be important to evaluate the dissolved oxygen concentration and self-purification ability of rivers.

  6. Evaluation of oxygen transfer parameters of fine-bubble aeration system in plug flow aeration tank of wastewater treatment plant.

    Science.gov (United States)

    Zhou, Xiaohong; Wu, Yuanyuan; Shi, Hanchang; Song, Yanqing

    2013-02-01

    Knowledge of the oxygen mass transfer of aerators under operational conditions in a full-scale wastewater treatment plant (WWTP) is meaningful for the optimization of WWTP, however, scarce to best of our knowledge. Through analyzing a plug flow aeration tank in the Lucun WWTP, in Wuxi, China, the oxygenation capacity of fine-bubble aerators under process conditions have been measured in-situ using the off-gas method and the non-steady-state method. The off-gas method demonstrated that the aerators in different corridors in the aeration tank of WWTP ha d significantly different oxygen transferperformance; furthermore, the aerators in the samecorridor shared almost equal oxygen transfer performance over the course of a day. Results measured by the two methods showed that the oxygen transfer performance of fine-bubble aerators in the aeration tank decreased dramatically compared with that in the clean water. The loss of oxygen transfer coefficient was over 50% under low-aeration conditions (aeration amount aeration amount reached 0.96 Nm3/hr, the discrepancy of oxygen transfer between the process condition and clean water was negligible. The analysis also indicated that the non-steady-state and off-gas methods resulted in comparable estimates of oxygen transfer parameters for the aerators under process conditions.

  7. Evaluation of oxygen transfer parameters of fine-bubble aeration system in plug flow aeration tank of wastewater treatment plant

    Institute of Scientific and Technical Information of China (English)

    Xiaohong Zhou; Yuanyuan Wu; Hanchang Shi; Yanqing Song

    2013-01-01

    Knowledge of the oxygen mass transfer of aerators under operational conditions in a full-scale wastewater treatment plant (WWTP) is meaningful for the optimization of WWTP,however,scarce to best of our knowledge.Through analyzing a plug flow aeration tank in the Lucun WWTP,in Wuxi,China,the oxygenation capacity of fine-bubble aerators under process conditions have been measured insitu using the off-gas method and the non-steady-state method.The off-gas method demonstrated that the aerators in different corridors in the aeration tank of WWTP had significantly different oxygen transfer performance; furthermore,the aerators in the same corridor shared almost equal oxygen transfer performance over the course of a day.Results measured by the two methods showed that the oxygen transfer performance of fine-bubble aerators in the aeration tank decreased dramatically compared with that in the clean water.The loss of oxygen transfer coefficient was over 50% under low-aeration conditions (aeration amount < 0.67 Nm3/hr).However,as the aeration amount reached 0.96 Nm3/hr,the discrepancy of oxygen transfer between the process condition and clean water was negligible.The analysis also indicated that the non-steady-state and off-gas methods resulted in comparable estimates of oxygen transfer parameters for the aerators under process conditions.

  8. Hydrodynamic behaviour of the lateral flow biological aerated filter

    Institute of Scientific and Technical Information of China (English)

    HE Qiang; WANG Yin; FANG Jun-hua; ZHANG Hong-jing; XU Jing

    2006-01-01

    Pulsed signal experiment was carried out to determine the hydrodynamic behaviours of lateral flow biological aerated filter(LBAF). With the analysis of experimental results, LBAF is viewed as an approximate plug flow reactor, and hydraulic retention time distribution function was derived based on LBAF. The results show that flow rate and aeration strength are two critical factors which influence flow patterns in LBAF reactor. The hydrodynamic behaviour analysis of LBAF is the theoretical basis of future research on improving capacity factor and developing kinetic model for the reactor.

  9. DIGITAL IMAGE MEASUREMENT OF BUBBLE MOTION IN AERATED WATER FLOWS

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    Digital image measurement method, as an ex-tension of Particle Image Velocimetry of single-phase flowmeasurement, was investigated for application to air-watertwo-phase flows. The method has strong potential ability inmeasuring bubble geometrical features and moving velocitiesfor complex bubble motion in aerated water flow. Both dilutedand dense bubble rising flows are measured using the digitalimage method. Measured bubble shapes and sizes, and bubblevelocities are affected by threshold selection for binary image.Several algorithms for selecting threshold are compared andmethods for calculating the time-averaged void fraction arediscussed.

  10. Effect of spray aeration on organics and nitrogen removal in vertical subsurface flow constructed wetland.

    Science.gov (United States)

    Ding, Yi; Wang, Wei; Song, Xin-Shan; Wang, Gang; Wang, Yu-Hui

    2014-12-01

    The objective of present study was to assess the simultaneous removal of organics and nitrogen by four lab-scale vertical subsurface flow constructed wetlands (V-SFCWs). The emergent plants employed were Canna indica. Five-month experiments showed that the planted and aerated system largely reduced the COD by 95%, NH4 by 88% and total inorganic nitrogen (TIN) by 83%. It outperformed the unplanted or simple aerated system and was much better than non-aerated system. The study provided a strong evidence to support widespread research and application of spray aeration as a low-cost and energy-efficient aeration technology in V-SFCWs.

  11. AN INVESTIGATION OF FLOW CHARACTERISTIC OF AERATED DRAG REDUCTION IN TUBE

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    Under the aerated conditions of wall and top intube, the turbulent flow in the tube was measured by usingLDA. The turbulent structure of the flow field and the mech-anism of aerating drag reduction in the tube were discussed. It is shown that the energy dissipations of turbulence flow andmean flow will reduce and the flow velocity (or flow rate) willincrease by injecting mini-bubbles to the wall or top of tube,namely the effect of aerating drag reduction is attained.

  12. SONIC SPEED AND SHOCK WAVE IN HIGH VELOCITY AERATED FLOWS FROM HIGH HEAD DISCHARGE STRUCTURES

    Institute of Scientific and Technical Information of China (English)

    Dong Zhi-yong

    2003-01-01

    The compressible characteristics in aerated flows at the high velocity of about 50m/s were analyzed. Based on the theory of compressible the relations between the sonic speed and shock wave in high-velocity aerated flow were theoretically deduced. And comparisons with measured data were made. The theoretical and experimental results show the sonic speed in aerated flow is merely of the order of several-dozen meters per second, and its minimum value is only 20m/s, which is far much less than that in water or air alone. So high subsonic flow, supersonic flow and transonic flow as well as compression wave, shock wave and expansion wave similarly to aerodnamics may be produced in high velocity aerated flow at the speed of the order of 50m/s. Hence the influences of these compressible characteristics on high head discharge structures can not be neglected, especially on super high dams over 200m high.

  13. EXPERIMENTAL INVESTIGATION ON SOUND SPEED PROPAGATING THROUGH HIGH SPEED AERATED FLOW IN OPEN CHANNEL

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    An experiment concerning the sound propaga-tion in aerated open channel flow was designed and conductedin a variable slope chute. The acquisition of sound data wasdone by the hydro-phones installed into the bottom wall of thechute. The data were analyzed and processed by the tape re-corder and a 3562A analyzer. The primary experimetal resultsindicated that the sound speed in aerated flow is varied with the air concentration and highly lower than each of the soundspeed in pure water or air. As released by the derived theoryformula, the minimum sound of 24m/s in aerated flow hap-pened when the air concentration achieved to 50%. This resultshows that the compressibility of high speed aerated flowshould be considered when the air concentration is near to50%. A criterion of compressibility of high speed aerated flowwas also giv. En in this paper.

  14. A two-fluid model for violent aerated flows

    CERN Document Server

    Dias, Frédéric; Ghidaglia, Jean-Michel

    2008-01-01

    In the study of ocean wave impact on structures, one often uses Froude scaling since the dominant force is gravity. However the presence of trapped or entrained air in the water can significantly modify wave impacts. When air is entrained in water in the form of small bubbles, the acoustic properties in the water change dramatically. While some work has been done to study small-amplitude disturbances in such mixtures, little work has been done on large disturbances in air-water mixtures. We propose a basic two-fluid model in which both fluids share the same velocities and analyze some of its properties. It is shown that this model can successfully mimic water wave impacts on coastal structures. The governing equations are discretized by a second-order finite volume method. Numerical results are presented for two examples: the dam break problem and the drop test problem. It is shown that this basic model can be used to study violent aerated flows, especially by providing fast qualitative estimates.

  15. Performance of Four Full-Scale Artificially Aerated Horizontal Flow Constructed Wetlands for Domestic Wastewater Treatment

    National Research Council Canada - National Science Library

    Butterworth, Eleanor; Richards, Andrew; Jones, Mark; Mansi, Gabriella; Ranieri, Ezio; Dotro, Gabriela; Jefferson, Bruce

    2016-01-01

      A comparison of the performance of four full-scale aerated horizontal flow constructed wetlands was conducted to determine the efficacy of the technology on sites receiving high and variable ammonia...

  16. Influence of aeration and initial water thickness on axial velocity attenuation of jet flows

    Institute of Scientific and Technical Information of China (English)

    Wang-ru WEI; Jun DENG; Bin LIU

    2013-01-01

    With the development of ski-jump energy dissipation for high and large discharge among the hydraulic projects,the effects of characteristics of water flow on energy dissipation are increasingly important.In the present study,the effects of aeration and the initial water thickness on axial velocity attenuation of jet flow were analyzed,using variance analysis and numerical calculated methods.From the analysis of test data,both of the air concentration and initial water thickness are sensitive factors for the axial velocity attenuation of jet flow along the axial way,and there is no significant interaction effect between the aeration and initial water thickness.Aeration has a more significant effect on the axial velocity attenuation of jet flow.Decreasing the initial water thickness of jet flow can reduce the length of jet core,and make the initial position of axial velocity attenuation closer to the nozzle exit.The numerical calculation results show that aeration can contribute to the enhancement of entrainment ability of jet flow,which may improve the interaction between jet flow and surroundings.For ski-jump energy dissipation among the hydraulic projects,combining aeration with decreasing initial water thickness of jet flow is an effective way to enhance the rate of axial velocity attenuation.

  17. Fluctuant characteristics of two-phase flow behind a bottom aerator

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    Experimental observations show that the random process of two-phase flow behind an aerator is an ergodic process and its amplitude distribution is similar to a normal distribution. The maximum pressure fluctuation is at the re-attachment point where the jet-trajectory flow over the aerator re-attaches to the bottom of the channel, and its amplitude is 2—3 times larger than when there is no aerator. There is a dominant frequency of 1.24 Hz in the model, but the coherence in the frequency domain is not obvious for other frequencies beside the dominant frequency. There is a large vortex at the re-attachment point behind the aerator but correlation among the measurement points is not obvious in the time domain.

  18. EXPERIMENTAL AND NUMERICAL SIMULATION OF THREE-PHASE FLOW IN AN AERATION TANK

    Institute of Scientific and Technical Information of China (English)

    Cheng Wen; Zhou Xiao-de; Song Ce; Min Tao; Murai Yuichi; Yamamoto Fujio

    2003-01-01

    Aeration plays an important role in the treatment of activated sludge due to the interactions among bubbles, sewage and activated sludge in an aeration tank. The aeration performance is directly concerned with the efficiency of sewage disposal. So the three-dimensional two-fluid model was established with emphasis on the phase interaction terms in this paper. This model, as an extension of the two-phase flow model, involved the motion laws of three-phases, and was compared with experimental studies. The finite volume method was used in the numerical simulation of gas-liquid two-phase flow and gas-liquid-solid three-phase flow. In order to discuss the influence of gas-phase, liquid-phase and solid-phase motions in an aeration tank on the sewage disposal, three kinds of boundary and initial conditions were adopted. The simulated results of the flow structure show qualitatively good agreement with the experimental data. And the theoretical basis for designing the best aeration tank was discussed according to the simulated results.

  19. Decentralized domestic wastewater treatment using intermittently aerated vertical flow constructed wetlands: impact of influent strengths.

    Science.gov (United States)

    Wu, Haiming; Fan, Jinlin; Zhang, Jian; Ngo, Huu Hao; Guo, Wenshan; Hu, Zhen; Liang, Shuang

    2015-01-01

    In this study, the removal performances of organic pollutants and nitrogen in vertical flow constructed wetlands (VFCWs) with and without intermittent aeration fed with different strengths of influent were evaluated as a possible treatment for decentralized domestic wastewater in northern China. The intermittent aeration strategy not only significantly increased removal efficiencies of organic pollutants and ammonium nitrogen (NH4(+)-N), but also successfully created alternate aerobic and anaerobic conditions resulting in high total nitrogen (TN) removal. Moreover, increasing influent strength did not affect the removal efficiencies of organic matters and nitrogen in aerated VFCWs. Compared with non-aerated VFCWs, much higher removal of organic pollutants (96%), NH4(+)-N (98%), and TN (85%) was obtained simultaneously in intermittent aeration VFCWs, especially at high influent strengths. The results suggest that the intermittent aeration could be an appropriate strategy for achieving the high removal performance in VFCWs, especially for in-situ treatment of high strength decentralized domestic wastewaters. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. THREE-DIMENSIONAL NUMERICAL SIMULATION OF AERATED FLOWS DOWNSTREAM SUDDEN FALL AERATOR EXPANSION-IN A TUNNEL

    Institute of Scientific and Technical Information of China (English)

    ZHANG Jian-min; CHEN Jian-gang; XU Wei-lin; WANG Yu-rong; LI Gui-ji

    2011-01-01

    Air entrainment is known to be one of efficient and inexpensive methods to prevent cavitation damages in hydropower projects.The shape of sudden expansion-fall is used as a common device for mitigating cavitation erosions.The complex flow patterns with cavitation are numerically simulated by using the realizable k-ε turbulence model and the air-water mixture model.The calculated results are compared well with the experimental results as well as those obtained with the k -ε turbulence model with the Volume Of Fluid (VOF) Model.The calculated results agree well with the experimental data for the aeration cavity and wall pressure.Moreover, the air concentration near sidewall is simulated by a mixture model.It is found that the mixture turbulence model is superior to the VOF turbulence model.

  1. Enhanced long-term organics and nitrogen removal and associated microbial community in intermittently aerated subsurface flow constructed wetlands.

    Science.gov (United States)

    Fan, Jinlin; Zhang, Jian; Guo, Wenshan; Liang, Shuang; Wu, Haiming

    2016-08-01

    The long-term enhanced removal efficiency of organics and nitrogen in subsurface flow constructed wetlands (SSF CWs) with and without intermittent aeration for decentralized domestic wastewater was evaluated, and the function of intermittent aeration on microbial community was also investigated in this study. The high and long-term 95.6% COD, 96.1% NH4(+)-N and 85.8% TN removal efficiencies were achieved in experimental intermittently aerated SSF CW compared with non-aerated SSF CW. Aerated SSF CWs also exhibited the excellent removal performance when comparatively comparing with other strategies and techniques applied in CWs. In addition, fluorescence in situ hybridization (FISH) analysis revealed that associated microbial abundance significantly increased owing to intermittent aeration. These results indicated intermittent aeration CWs might be an effective and sustainable strategy for wastewater treatment in rural areas, but require further full-scale investigation in future.

  2. CAVITATION CHARACTERISTICS OF HIGH VELOCITY FLOW WITH AND WITHOUT AERATION ON THE ORDER OF 50 m/s

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Experimental study of cavitation characteristics with and without aeration was conducted at the flow velocity 50m/s in the non-circulating type water tunnel in the Hydraulics Laboratory at Zhejiang University of Technology. Variations of pressure and cavitation number with air concentration, pressure waveforms as well as cavitation erosion level of concrete specimen with and without aeration were obtained. The effects of cavitation control by aeration were analyzed.

  3. [Effect of Intermittent Aeration on Nitrogen Removal Efficiency in Vertical Subsurface Flow Constructed Wetland].

    Science.gov (United States)

    Wang, Jian; Li, Huai-zheng; Zhen, Bao-chong; Liu, Zhen-dong

    2016-03-15

    One-stage vertical subsurface flow constructed wetlands (CWs) were used to treat effluent from grit chamber in municipal wastewater treatment plant. The CW was divided into aerobic zone and anoxic zone by means of raising the effluent level and installing a perforated pipe. Two parameters (the ratio of aeration time and nonaeration time, aeration cycle) were optimized in the experiment to enhance nitrogen removal efficiency. The results suggested that the removal rates of COD and NH₄⁺-N increased while TN showed a trend of first increasing and then decreasing with the increasing ratio. When the ratio was 3:1, the C/N value in the anoxic zone was 4. 8. And the TN effluent concentration was 15.8 mg · L⁻¹ with the highest removal rate (62.1%), which was increased by 12.7% compared with continuous aeration. As the extension of the aeration cycle, the DO effluent concentration as well as the removal rates of COD and NH: -N declined gradually. The TN removal rate reached the maximum (65.5%) when the aeration cycle was 6h. However, the TN removal rate dropped rapidly when the cycle exceeded the hydraulic retention time in the anoxic zone.

  4. Vagal denervation inhibits the increase in pulmonary blood flow during partial lung aeration at birth.

    Science.gov (United States)

    Lang, Justin A R; Pearson, James T; Binder-Heschl, Corinna; Wallace, Megan J; Siew, Melissa L; Kitchen, Marcus J; Te Pas, Arjan B; Lewis, Robert A; Polglase, Graeme R; Shirai, Mikiyasu; Hooper, Stuart B

    2017-03-01

    Lung aeration at birth significantly increases pulmonary blood flow, which is unrelated to increased oxygenation or other spatial relationships that match ventilation to perfusion. Using simultaneous X-ray imaging and angiography in near-term rabbits, we investigated the relative contributions of the vagus nerve and oxygenation to the increase in pulmonary blood flow at birth. Vagal denervation inhibited the global increase in pulmonary blood flow induced by partial lung aeration, although high inspired oxygen concentrations can partially mitigate this effect. The results of the present study indicate that a vagal reflex may mediate a rapid global increase in pulmonary blood flow in response to partial lung aeration. Air entry into the lungs at birth triggers major cardiovascular changes, including a large increase in pulmonary blood flow (PBF) that is not spatially related to regional lung aeration. To investigate the possible underlying role of a vagally-mediated stimulus, we used simultaneous phase-contrast X-ray imaging and angiography in near-term (30 days of gestation) vagotomized (n = 15) or sham-operated (n = 15) rabbit kittens. Rabbits were imaged before ventilation, when one lung was ventilated (unilateral) with 100% nitrogen (N2 ), air or 100% oxygen (O2 ), and after all kittens were switched to unilateral ventilation in air and then ventilation of both lungs using air. Compared to control kittens, vagotomized kittens had little or no increase in PBF in both lungs following unilateral ventilation when ventilation occurred with 100% N2 or with air. However, relative PBF did increase in vagotomized animals ventilated with 100% O2 , indicating the independent stimulatory effects of local oxygen concentration and autonomic innervation on the changes in PBF at birth. These findings demonstrate that vagal denervation inhibits the previously observed increase in PBF with partial lung aeration, although high inspired oxygen concentrations can partially

  5. Effect of artificial aeration on the performance of vertical-flow constructed wetland treating heavily polluted river water

    Institute of Scientific and Technical Information of China (English)

    Huiyu Dong; Zhimin Qiang; Tinggang Li; Hui Jin; Weidong Chen

    2012-01-01

    Three lab-scale vertical-flow constructed wetlands (VFCWs),including the non-aerated (NA),intermittently aerated (IA) and continuously aerated (CA) ones,were operated at different hydraulic loading rates (HLRs) to evaluate the effect of artificial aeration on the treatment efficiency of heavily polluted river water.Results indicated that artificial aeration increased the dissolved oxygen (DO) concentrations in IA and CA,which significantly favored the removal of organic matter and NH4+-N.The DO grads caused by intermittent aeration formed aerobic and anoxic regions in IA and thus promoted the removal of total nitrogen (TN).Although the removal efficiencies of CODcr,NH4+-N and TN in the three VFCWs all decreased with an increase in HLR,artificial aeration enhanced the reactor resistance to the fluctuation of pollutant loadings.The maximal removal efficiencies of CODcr,NH4+-N and total phosphorus (TP) (i.e.,81%,87% and 37%,respectively) were observed in CA at 19 cm/day HLR,while the maximal TN removal (i.e.,57%) was achieved in IA.Although the improvement of artificial aeration on TP removal was limited,this study has demonstrated the feasibility of applying artificial aeration to VFCWs treating polluted eiver water,particularly at a high HLR.

  6. Computational Fluid Dynamics Simulation of Flows in an Oxidation Ditch Driven by a New Surface Aerator.

    Science.gov (United States)

    Huang, Weidong; Li, Kun; Wang, Gan; Wang, Yingzhe

    2013-11-01

    In this article, we present a newly designed inverse umbrella surface aerator, and tested its performance in driving flow of an oxidation ditch. Results show that it has a better performance in driving the oxidation ditch than the original one with higher average velocity and more uniform flow field. We also present a computational fluid dynamics model for predicting the flow field in an oxidation ditch driven by a surface aerator. The improved momentum source term approach to simulate the flow field of the oxidation ditch driven by an inverse umbrella surface aerator was developed and validated through experiments. Four kinds of turbulent models were investigated with the approach, including the standard k-ɛ model, RNG k-ɛ model, realizable k-ɛ model, and Reynolds stress model, and the predicted data were compared with those calculated with the multiple rotating reference frame approach (MRF) and sliding mesh approach (SM). Results of the momentum source term approach are in good agreement with the experimental data, and its prediction accuracy is better than MRF, close to SM. It is also found that the momentum source term approach has lower computational expenses, is simpler to preprocess, and is easier to use.

  7. EXPERIMENTAL STUDY ON THE GAS-LIQUID FLOW IN THE MEMBRANE MICROPORE AERATION BIOREACTOR

    Directory of Open Access Journals (Sweden)

    DONG LIU

    2008-12-01

    Full Text Available Particle Image Velocimetry (PIV has been developed to measure the typical two-phase flow of various work conditions in Membrane Micropore Aeration Bioreactor (MMAB. The fluid phase is separated out using image processing techniques, which provides accurate measurements for the Bioreactor’s flow field, and makes it possible for quantitative analysis of the momentum exchange, heat exchange and the process of micro-admixture. The experimental method PIV used in this paper can preferably measure the complex flow in the reactor and initiates a new approach for the bioreactor design which mainly depends on experience at present.

  8. Pathways of nitrobenzene degradation in horizontal subsurface flow constructed wetlands: Effect of intermittent aeration and glucose addition.

    Science.gov (United States)

    Kirui, Wesley K; Wu, Shubiao; Kizito, Simon; Carvalho, Pedro N; Dong, Renjie

    2016-01-15

    Intermittent aeration and addition of glucose were applied to horizontal subsurface flow constructed wetlands in order to investigate the effect on pathways of nitrobenzene (NB) degradation and interactions with microbial nitrogen and sulphur transformations. The experiment was carried out in three phases A, B and C consisting of different NB loading and glucose dosing. For each phase, the effect of aeration was assessed by intermittently aerating one wetland and leaving one unaerated. Regardless of whether or not the wetland was aerated, at an influent NB concentration of 140 mg/L, both wetlands significantly reduced NB to less than 2 mg/L, a reduction efficiency of 98%. However, once the influent NB concentration was increased to 280 mg/L, the aerated wetland had a higher removal performance 82% compared to that of the unaerated wetland 71%. Addition of glucose further intensified the NB removal to 95% in the aerated wetlands and 92% in the unaerated. Aeration of wetlands enhanced NB degradation, but also resulted in higher NB volatilization of 6 mg m(-2) d(-1). The detected high concentration of sulphide 20-60 mg/L in the unaerated wetland gave a strong indication that NB may act as an electron donor to sulphate-reducing bacteria, but this should be further investigated. Aeration positively improved NB removal in constructed wetlands, but resulted in higher NB volatilization. Glucose addition induced co-metabolism to enhance NB degradation.

  9. Performance of simultaneous nitrification and denitrification in lateral flow biological aerated filter

    Institute of Scientific and Technical Information of China (English)

    LONG Teng-rui; CAO Yan-xiao; ZHANG Hong-jing; GAO Xiao-tao

    2006-01-01

    A new wastewater treatment facility-lateral flow biological aerated filter (LBAF) was developed aiming at solving energy consumption and operational problems in wastewater treatment facilities in small towns. It has the function of nitrification and removing organic substrate. In this study, we focused on the denitrification performance of LBAF and its possible mechanism under thorough aeration. We identified the existence of simultaneous nitrification and denitrification (SND)by analyzing nitrogenous compounds along the flow path of LBAF and supportive microbial microscopy, and studied the effects of air/water ratio and hydraulic loading on the performance of nitrogen removal and on SND in LBAF to find out the optimal operation condition. It is found that for saving operation cost, aeration can be reduced to some degree that allows desirable removal efficiency of pollutants, and the optimal air/water ratio is 10:1. Hydraulic loading less than 0.43 m h-1 hardly affects the nitrification and denitrification performance; whereas higher hydraulic loading is unfavorable to both nitrification and denitrification, far more unfavorable to denitrification than to nitrification.

  10. Performances of lateral flow biological aerated filter in treating domestic wastewater

    Institute of Scientific and Technical Information of China (English)

    ZHANG Hong-jing; LONG Teng-rui; CAO Yan-xiao

    2006-01-01

    A new biological aerated filter--lateral flow biological aerated filter(LBAF) is developed.The effects of air/water ratio,hydraulic loading and the length of LBAF on pollutants removal efficiency are tested.The results show that under optimal technological conditions when hydraulic loading is 0.43 m3 m(2 h(1 and air/water ratio is 10:1,the average removal efficiencies of COD,SS,NH3-N,and TN reach 88.01%,95.18%,78.97% and 52.58%,respectively.An LBAF has a large pollutants handling capacity; is less liable to be blocked,and has a longer operation cycle in comparison with a traditional BAF.

  11. Large eddy simulation of dilute bubbly turbulent flows for aerating hydrofoils

    Science.gov (United States)

    Hajit, Mohammad; Sotiropoulos, Fotis

    2014-11-01

    We have proposed a formulation for the large eddy simulation of dilute bubbly flows by converting the governing equations to a more loosely-coupled form. This formulation provides an efficient numerical procedure for two-way coupling of bubbly flows at low gas holdups. Subgrid-scale turbulence modeling is based on the dynamic procedure of Germano for the liquid phase and the Jakobson approach for the gas phase. Wall-modeling is implemented using the method of Cabot & Moin. Our approach is employed to simulate flow over aerating hydrofoils at different angles of attack. A structured body-fitted C-grid is employed for domain discretization. Validation of our computational code, for C-grids, is carried out by simulating single-phase flows over a NACA0012 airfoil (20° AOA) with laminar flow and an E387 airfoil (6° AOA) with turbulent flow. Comparisons with available computational and experimental data in terms of time averaged drag coefficient, lift coefficient, separation bubble length, and reattachment point proves the validity of our computational code. The aerating hydrofoil simulation utilizes a NACA0015 hydrofoil, for which experiments were carried out at Saint Anthony Falls Laboratory. Comparisons between computational and experimental datasets show promising results. This work is supported by the U.S. Dept. of Energy and the Hydro Reasearch Foundation.

  12. Nitrogen removal in wood chip combined substrate baffled subsurface-flow constructed wetlands: impact of matrix arrangement and intermittent aeration.

    Science.gov (United States)

    Li, Huai; Chi, Zifang; Yan, Baixing; Cheng, Long; Li, Jianzheng

    2017-02-01

    In this study, two lab-scale baffled subsurface-flow constructed wetlands (BSFCWs), including gravel-wood chips-slag and gravel-slag-wood chips, were operated at different intermittent aeration to evaluate the effect of artificial aeration and slow-released carbon source on the treatment efficiency of high-strength nitrogen wastewater. Results indicated that gravel-slag-wood chips extended aerobic/anaerobic alternating environment to gravel and slag zones and maintained anaerobic condition in the subsequent wood chip section. The order of gravel-slag-wood chip was more beneficial to pollutant removal. Sufficient carbon source supply resulted from wood-chip-framework substrate simultaneously obtained high removals of COD (97%), NH4(+)-N (95%), and TN (94%) in BSFCWs at 2 h aeration per day. The results suggest that intermittent aeration combined with wood chips could achieve high nitrogen removal in BSFCWs.

  13. Turbulence, aeration and bubble features of air-water flows over macro- and intermediate roughness

    Directory of Open Access Journals (Sweden)

    Stefano PAGLIARA

    2011-06-01

    Full Text Available Free surface flows in macro- and intermediate roughness conditions have a high aeration potential in which the flow characteristics vary with slopes and discharges. The underlying phenomenon of two phase flow characteristics in the macro and intermediate roughness conditions were analyzed in a setup assembled at the PITLAB center of the University of Pisa, Italy. Crushed angular rocks and hemispherical boulders were used to intensify the roughness nature of the bed. Flow discharges per unit width ranging between 0.03 m2/s and 0.09 m2/s and slopes between 0.26 and 0.46 were tested over different arrangements of rough bed. Analyses were mainly concentrated in the inner flow region which constitutes both bubbly and intermediate flow region. The findings revealed that two phase flow properties over rough bed were very much affected by the different rough bed arrangement. Turbulence features of two phase flows over rough beds were compared with that of the stepped chute data under similar flow conditions. Overall the results highlighted the flow features in the inner layers of the two phase flow.

  14. Comparison of vertical-flow constructed wetlands with and without supplementary aeration treating decentralized domestic wastewater.

    Science.gov (United States)

    Zhu, Liandong; Takala, Josu; Hiltunen, Erkki; Li, Zhaohua; Kristianto, Yohanes

    2013-01-01

    Constructed wetlands (CWs) are efficient in reducing excessive contamination from wastewaters. However, oxygen inside CW beds is frequently low especially when substrate clogging problems appear after long-term operation, and this may become a limited factor for the treatment of wastewaters. Aimed at dealing with the issue of a low oxygen content in CW systems, two laboratory-scale vertical-flow constructed wetlands (VFCWs) with and without an aeration device (called VFCW-a and VFCW-c, respectively) were designed in this study to test the contribution of supplementary aeration to the treatment of decentralized domestic wastewater. Results showed that under the intermittent operation of about 45 days, two VFCW units were successfully started up by using activated sludge as seed sludge. Compared to VFCW-c, VFCW-a had a better resistance ability to organic shock loads and its removal function could be effectively recovered within a short period after the introduction of organic shock loads. Under intermittent operation with a 12 h idling time, the ideal hydraulic retention time (HRT) of VFCW-a was 42 h, about 6 h shorter than that of VFCW-c. Likewise, under intermittent operation with 42 h HRT, the ideal idling time of VFCW-a was 12 h, still about 6 h shorter than that of VFCW-c. Under intermittent operation with HRT-42 h and an idling time of 12 h, SS, COD, TN and TP removal efficiencies in VFCW-a could reach 81.2%, 85%, 89.9% and 77.9%, respectively. The VFCW unit with supplementary aeration is an efficient innovation for the treatment of decentralized domestic wastewater.

  15. Performance of Four Full-Scale Artificially Aerated Horizontal Flow Constructed Wetlands for Domestic Wastewater Treatment

    Directory of Open Access Journals (Sweden)

    Eleanor Butterworth

    2016-08-01

    Full Text Available A comparison of the performance of four full-scale aerated horizontal flow constructed wetlands was conducted to determine the efficacy of the technology on sites receiving high and variable ammonia loading rates not yet reported in the literature. Performance was assessed in terms of ammonia and solids removal, hydraulic conductivity and mixing patterns. The capability of systems to produce ammonium effluent concentrations <3 mgNH4+-N/L was observed across all sites in systems receiving variable loadings between 0.1 and 13.0 gNH4+-N/m2/d. Potential resilience issues were observed in relation to response to spike loadings posited to be due to an insufficient nitrifying population within the beds. Hydraulic conductivity and flow mixing patterns observed suggested deterioration of the reactor effective volume over time. Overall, the study demonstrates the efficacy of the technology where ammonium removal is required on small sites receiving high and variable flow rates, with adequate removal of organics and solids, but no significant benefit to the long term hydraulics of the system.

  16. Recirculation or artificial aeration in vertical flow constructed wetlands: a comparative study for treating high load wastewater.

    Science.gov (United States)

    Foladori, Paola; Ruaben, Jenny; Ortigara, Angela R C

    2013-12-01

    Vertical subsurface-flow constructed wetlands at pilot-scale have been applied to treat high hydraulic and organic loads by implementing the following configurations: (1) intermittent recirculation of the treated wastewater from the bottom to the top of the bed, (2) intermittent artificial aeration supplied at the bottom of the bed and (3) the combination of both. These configurations were operated with a saturated bottom layer for a 6h-treatment phase, followed by a free drainage phase prior to a new feeding. COD removal efficiency was 85-90% in all the configurations and removed loads were 54-70 gCOD m(-2)d(-1). The aerated and recirculated wetland resulted in a higher total nitrogen removal (8.6 gN m(-2)d(-1)) due to simultaneous nitrification/denitrification, even in the presence of intermittent aeration (6.8 Nm(3)m(-2)d(-1)). The extra investment needed for implementing aeration/recirculation would be compensated for by a reduction of the surface area per population equivalent, which decreased to 1.5m(2)/PE. Copyright © 2013 Elsevier Ltd. All rights reserved.

  17. Onsite survey on the mechanism of passive aeration and air flow path in a semi-aerobic landfill.

    Science.gov (United States)

    Matsuto, Toshihiko; Zhang, Xin; Matsuo, Takayuki; Yamada, Shuhei

    2015-02-01

    The semi-aerobic landfill is a widely accepted landfill concept in Japan because it promotes stabilization of leachates and waste via passive aeration without using any type of mechanical equipment. Ambient air is thought to be supplied to the landfill through a perforated pipe network made of leachate collection pipe laid along the bottom and a vertically erected gas vent. However, its underlying air flow path and driving forces are unclear because empirical data from real-world landfills is inadequate. The objective of this study is to establish scientific evidence about the aeration mechanisms and air flow path by an on-site survey of a full-scale, semi-aerobic landfill. First, all passive vents located in the landfill were monitored with respect to temperature level and gas velocity in different seasons. We found a linear correlation between the outflow rate and gas temperature, suggesting that air flow is driven by a buoyancy force caused by the temperature difference between waste in the landfill and the ambient temperature. Some vents located near the landfill bottom acted as air inflow vents. Second, we conducted a tracer test to determine the air flow path between two vents, by injecting tracer gas from an air sucking vent. The resulting slowly increasing gas concentration at the neighboring vent suggested that fresh air flow passes through the waste layer toward the gas vents from leachate collection pipes, as well as directly flowing through the pipe network. Third, we monitored the temperature of gas flowing out of a vent at night. Since the temperature drop of the gas was much smaller than that of the environment, the air collected at the gas vents was estimated to flow mostly through the waste layer, i.e., the semi-aerobic landfill has considerable aeration ability under the appropriate conditions.

  18. The Application of EIS and PIV Methods to the Measurement of Aerated Flow

    Directory of Open Access Journals (Sweden)

    Fejfarová M.

    2013-04-01

    Full Text Available The paper describes measurements in the aerated water medium using modern methods PIV (Particle Image Velocimetry and EIS (Electrical Impedance Spectrometry, which are applied in the Laboratory of Water Management Research (LVV of the Department of Water Structures (UVST at the Faculty of Civil Engineering (FAST of Brno University of Technology (VUT. Measurements of the water medium were carried out for three different aeration intensities at special experimental workplaces. The experiment was focused on the capability of the methods to monitor the air content in the water.

  19. AN EXPERIMENTAL INVESTIGATION OF PRESSURE AND CAVITATION CHARACTERISTICS OF HIGH VELOCITY FLOW OVER A CYLINDRICAL PROTRUSION IN THE PRESENCE AND ABSENCE OF AERATION

    Institute of Scientific and Technical Information of China (English)

    DONG Zhi-yong; LIU Zhi-ping; WU Yi-hong; ZHANG Dong

    2008-01-01

    This article experimentally investigated the pressure and cavitation characteristics of high velocity flow over a surface irregularity with and without aeration in a non-circulating water tunnel system. The surface irregularity is a cylindrical protrusion made of stainless steel of 6 mm diameter and 2 mm height. Pressures with and without aeration were measured with MPX400D pressure transducers and real-timely acquired by a SINOCERA YE6263 data acquisition system. Variations in flow regimes with and without aeration were observed. Pressure profiles and their variations with air concentration upper and lower cylindrical protrusion on the invert and obvert walls were determined. Variations of cavitation number with air concentration lower cylindrical protrusion were analyzed. Also, cavitation numbers in the presence and absence of aeration were compared.

  20. Role of macrophyte and effect of supplementary aeration in up-flow constructed wetland-microbial fuel cell for simultaneous wastewater treatment and energy recovery.

    Science.gov (United States)

    Oon, Yoong-Ling; Ong, Soon-An; Ho, Li-Ngee; Wong, Yee-Shian; Dahalan, Farrah Aini; Oon, Yoong-Sin; Lehl, Harvinder Kaur; Thung, Wei-Eng; Nordin, Noradiba

    2017-01-01

    This study investigates the role of plant (Elodea nuttallii) and effect of supplementary aeration on wastewater treatment and bioelectricity generation in an up-flow constructed wetland-microbial fuel cell (UFCW-MFC). Aeration rates were varied from 1900 to 0mL/min and a control reactor was operated without supplementary aeration. 600mL/min was the optimum aeration flow rate to achieve highest energy recovery as the oxygen was sufficient to use as terminal electron acceptor for electrical current generation. The maximum voltage output, power density, normalized energy recovery and Coulombic efficiency were 545.77±25mV, 184.75±7.50mW/m(3), 204.49W/kg COD, 1.29W/m(3) and 10.28%, respectively. The variation of aeration flow rates influenced the NO3(-) and NH4(+) removal differently as nitrification and denitrification involved conflicting requirement. In terms of wastewater treatment performance, at 60mL/min aeration rate, UFCW-MFC achieved 50 and 81% of NO3(-) and NH4(+) removal, respectively. E. nuttallii enhanced nitrification by 17% and significantly contributed to bioelectricity generation.

  1. Analytical models for complex swirling flows

    Science.gov (United States)

    Borissov, A.; Hussain, V.

    1996-11-01

    We develops a new class of analytical solutions of the Navier-Stokes equations for swirling flows, and suggests ways to predict and control such flows occurring in various technological applications. We view momentum accumulation on the axis as a key feature of swirling flows and consider vortex-sink flows on curved axisymmetric surfaces with an axial flow. We show that these solutions model swirling flows in a cylindrical can, whirlpools, tornadoes, and cosmic swirling jets. The singularity of these solutions on the flow axis is removed by matching them with near-axis Schlichting and Long's swirling jets. The matched solutions model flows with very complex patterns, consisting of up to seven separation regions with recirculatory 'bubbles' and vortex rings. We apply the matched solutions for computing flows in the Ranque-Hilsch tube, in the meniscus of electrosprays, in vortex breakdown, and in an industrial vortex burner. The simple analytical solutions allow a clear understanding of how different control parameters affect the flow and guide selection of optimal parameter values for desired flow features. These solutions permit extension to other problems (such as heat transfer and chemical reaction) and have the potential of being significantly useful for further detailed investigation by direct or large-eddy numerical simulations as well as laboratory experimentation.

  2. Fibrous Support Stabilizes Nitrification Performance of a Membrane-Aerated Biofilm: The Effect of Liquid Flow Perturbation

    DEFF Research Database (Denmark)

    Terada, Akihiko; Ito, J; Matsumoto, S

    2009-01-01

    Nitrification stability and biofilm robustness were examined by comparing a fibrous support membrane-aerated biofilm reactor (FS-MABR), where a woven fibrous support was surrounded on a silicone tube, with an MABR. The overall mass transfer coefficient of oxygen for the FS-MABR, assuming no bound......Nitrification stability and biofilm robustness were examined by comparing a fibrous support membrane-aerated biofilm reactor (FS-MABR), where a woven fibrous support was surrounded on a silicone tube, with an MABR. The overall mass transfer coefficient of oxygen for the FS-MABR, assuming...... liquid flow rate condition was 49% and 75% in the FS-MABR and MABR, exhibiting robust biofilms grown on the fibrous support. The FS-MABR provided more stable nitrification performance than the MABR irrespective of a high liquid flow rate. Both reactors have deteriorated ammonium (NH4+-N) removal without...... a high liquid flow rate condition to eliminate excessive biomass, indicating that regular maintenance is essential to eliminate excessive biofilm from a MABR for nitrification, which potentially acts as a NH4+ diffusion barrier....

  3. Enhanced organics and nitrogen removal in batch-operated vertical flow constructed wetlands by combination of intermittent aeration and step feeding strategy.

    Science.gov (United States)

    Fan, Jinlin; Liang, Shuang; Zhang, Bo; Zhang, Jian

    2013-04-01

    Oxygen and carbon source supply are usually insufficient in subsurface flow constructed wetlands. Simultaneous removal of organic pollutants and nitrogen in five batch-operated vertical flow constructed wetlands under different operating conditions was investigated. Alternate aerobic and anaerobic regions were created well with intermittent aeration. Four-month experiments showed that the wetland-applied intermittent aeration combined with step feeding strategy (reactor E) greatly improved the removal of organics, ammonium nitrogen (NH4-N), and total nitrogen (TN) simultaneously, which were 97, 96, and 82%, respectively. It was much better than non-aerated reactors A and B and outperformed intermittently aerated reactor D without step feeding. Continuous aeration (reactor C) significantly enhanced the organics removal and nitrification, but it limited the TN removal (29%) seriously as a result of low denitrification level, and the high operation cost remained a question. The effect of plants was confirmed in this study, and the monitoring data showed that the plants could grow normally. Intermittent aeration as well as step feeding had no obvious influence on the growth of wetland plants in this study.

  4. Research on influence of discharge tunnel slope on aerated water flow

    Science.gov (United States)

    Chen, Hui; Chen, Baiquan

    2017-08-01

    The influence on hydraulic characteristics and the law of aeration concentration change was studied of slope in the different slope of the bottoms by the experiments, and some benefit conclusions was get. With the experimental data, the empirical formulas of hydraulic calculation of the diversion tunnel was revised which can provide a reference for the design of the project with the sudden expansion and drainage.

  5. EXPERIMENTAL STUDY ON A NEW TYPE OF AERATOR IN SPILLWAY WITH LOW FROUDE NUMBER AND MILD SLOPE FLOW

    Institute of Scientific and Technical Information of China (English)

    SU Pei-lan; LIAO Hua-sheng; QIU Yue; LI Chen-juan

    2009-01-01

    Experimental study on aeration characteristics of various aeration devices was conducted in the spillway tunnel of the Pubugou hydropower project, Sichuan Province, China. It is shown by comparison that the new type of aeration device, namely, the aerator with a trapezoidal-shaped slot and a steep-slope section(ATSS), can avoid water accumulation in the cavity of the aeration device in the project, thus can effectively solve the backwater problems arising from this project and be used for a wide range of different water levels, without any drain facilities. Above the water level of 840 m, the water contained in the cavity can be eliminated completely, which means that the recommended new type of aerator can meet the aeration demands in the spillway of the project with low Froude number and may be of practical significance and of interest to other projects with similar types of aeration devices.

  6. Potential of aeration flow rate and bio-char addition to reduce greenhouse gas and ammonia emissions during manure composting

    DEFF Research Database (Denmark)

    Chowdhury, Md Albarune; de Neergaard, Andreas; Jensen, Lars Stoumann

    2014-01-01

    Aeration is an important factor influencing CO2, CH4, N2O and NH3 emissions from the composting process. Both CH4 and N2O are potent greenhouse gases (GHG) of high importance. Here, we examined the effects of high and low aeration rates together with addition of barley straw with and without bio......-char on GHG and NH3 emissions from composting cattle slurry and hen manure in small-scale laboratory composters. Depending on treatment, cumulative C losses via CO2 and CH4 emissions accounted for 11.4-22.5% and 0.004-0.2% of initial total carbon, while N losses as N2O and NH3 emissions comprised 0.......05-0.1% and 0.8-26.5% of initial total nitrogen, respectively. Decreasing the flow rate reduced cumulative NH3 losses non-significantly (by 88%) but significantly increased CH4 losses (by 51%) from composting of cattle slurry with barley straw. Among the hen manure treatments evaluated, bio-char addition...

  7. Laboratory model study of the effect of aeration on axial velocity attenuation of turbulent jet flows in plunge pool

    Institute of Scientific and Technical Information of China (English)

    邓军; 张法星; 田忠; 许唯临; 刘斌; 卫望汝

    2015-01-01

    In the laboratory model experiment, the velocities of the jet flow along the axis are measured, using the CQY−Z8a velocity-meter. The velocity attenuations of the jet flow along the axis under different conditions are studied. The effects of the aeration concentration, the initial jet velocity at the entry and the thickness of the jet flow on the velocity attenuation of the jet flow are analyzed. It is seen that the velocity attenuation of the jet flow along the axis sees a regular variation. It is demonstrated by the test results that under the experimental conditions, the velocity along the axis decreases linearly. The higher the air concentration is, the faster the velocity will be decayed. The absolute value of the slopeK increases with the rise of the air concentration. The relationship can be defined as=a+bKACK. The coefficientA is 0.03 under the experimental conditions. With the low air concentration of the jet flow, the thinner the jet flow is, the faster the velocity will be decayed. With the increase of the air concentra- tion, the influence of the thickness of the jet flow on the velocity attenuation is reduced. When the air concentration is increased to a certain value, the thickness of the jet flow may not have any influence on the velocity attenuation. The initial jet velocity itself at the entry has no influence on the variation of the velocity attenuation as the curves of the velocity attenuation at different velocities at the entry are practically parallel, even coinciding one with another. Therefore, improving the air concentration of the jet flow and disper- sing the jet flow in the plunge pool could reduce the influence of the jet flow on the scour.

  8. Improving microalgal growth with reduced diameters of aeration bubbles and enhanced mass transfer of solution in an oscillating flow field.

    Science.gov (United States)

    Yang, Zongbo; Cheng, Jun; Lin, Richen; Zhou, Junhu; Cen, Kefa

    2016-07-01

    A novel oscillating gas aerator combined with an oscillating baffle was proposed to generate smaller aeration bubbles and enhance solution mass transfer, which can improve microalgal growth in a raceway pond. A high-speed photography system (HSP) was used to measure bubble diameter and generation time, and online precise dissolved oxygen probes and pH probes were used to measure mass-transfer coefficient and mixing time. Bubble diameter and generation time decreased with decreased aeration gas rate, decreased orifice diameter, and increased water velocity in the oscillating gas aerator. The optimized oscillating gas aerator decreased bubble diameter and generation time by 25% and 58%, respectively, compared with a horizontal tubular gas aerator. Using an oscillating gas aerator and an oscillating baffle in a raceway pond increased the solution mass-transfer coefficient by 15% and decreased mixing time by 32%; consequently, microalgal biomass yield increased by 19%.

  9. Numerical Simulations of Two-Phase Flow in a Self-Aerated Flotation Machine and Kinetics Modeling

    KAUST Repository

    Fayed, Hassan E.

    2015-03-30

    A new boundary condition treatment has been devised for two-phase flow numerical simulations in a self-aerated minerals flotation machine and applied to a Wemco 0.8 m3 pilot cell. Airflow rate is not specified a priori but is predicted by the simulations as well as power consumption. Time-dependent simulations of two-phase flow in flotation machines are essential to understanding flow behavior and physics in self-aerated machines such as the Wemco machines. In this paper, simulations have been conducted for three different uniform bubble sizes (db = 0.5, 0.7 and 1.0 mm) to study the effects of bubble size on air holdup and hydrodynamics in Wemco pilot cells. Moreover, a computational fluid dynamics (CFD)-based flotation model has been developed to predict the pulp recovery rate of minerals from a flotation cell for different bubble sizes, different particle sizes and particle size distribution. The model uses a first-order rate equation, where models for probabilities of collision, adhesion and stabilization and collisions frequency estimated by Zaitchik-2010 model are used for the calculation of rate constant. Spatial distributions of dissipation rate and air volume fraction (also called void fraction) determined by the two-phase simulations are the input for the flotation kinetics model. The average pulp recovery rate has been calculated locally for different uniform bubble and particle diameters. The CFD-based flotation kinetics model is also used to predict pulp recovery rate in the presence of particle size distribution. Particle number density pdf and the data generated for single particle size are used to compute the recovery rate for a specific mean particle diameter. Our computational model gives a figure of merit for the recovery rate of a flotation machine, and as such can be used to assess incremental design improvements as well as design of new machines.

  10. Characterization of the external and internal flow structure of an aerated-liquid injector using X-ray radiography and fluorescence

    Science.gov (United States)

    Peltier, Scott J.; Lin, Kuo-Cheng; Carter, Campbell D.; Kastengren, Alan L.

    2017-09-01

    In the present study, the internal flowfield of aerated-liquid fuel injectors is examined through X-ray radiography and X-ray fluorescence. An inside- out injector, consisting of a perforated aerating tube within an annular liquid stream, sprays into a quiescent environment at a fixed mass flow rate of water and nitrogen gas. The liquid is doped with bromine (in the form of NaBr) to create an X-ray fluorescence signal. This allows for reasonable absorption and fluorescence signals, and one or both diagnostics can be used to track the liquid distribution. The injector housing is fabricated from beryllium (Be), which allows the internal flowfield to be examined (as Be has relatively low X-ray attenuation coefficient). Two injector geometries are compared, illustrating the effects of aerating orifice size and location on the flow evolution. Time-averaged equivalent pathlength and line-of-sight averaged density ρ( y) reveal the formation of the two-phase mixture, showing that the liquid film thickness along the injector walls is a function of the aerating tube geometry, though only upstream of the nozzle. These differences in gas and liquid distribution (between injectors with different aerating tube designs) are suppressed as the mixture traverses the nozzle contraction. The averaged liquid velocity (computed from the density and liquid mass flow rate) reveals a similar trend. This suggests that at least for the current configurations, the plume width, liquid mass distribution, and averaged liquid velocity for the time-averaged external spray are insensitive to the aerating tube geometry.

  11. Visualizing Flow of Uncertainty through Analytical Processes.

    Science.gov (United States)

    Wu, Yingcai; Yuan, Guo-Xun; Ma, Kwan-Liu

    2012-12-01

    Uncertainty can arise in any stage of a visual analytics process, especially in data-intensive applications with a sequence of data transformations. Additionally, throughout the process of multidimensional, multivariate data analysis, uncertainty due to data transformation and integration may split, merge, increase, or decrease. This dynamic characteristic along with other features of uncertainty pose a great challenge to effective uncertainty-aware visualization. This paper presents a new framework for modeling uncertainty and characterizing the evolution of the uncertainty information through analytical processes. Based on the framework, we have designed a visual metaphor called uncertainty flow to visually and intuitively summarize how uncertainty information propagates over the whole analysis pipeline. Our system allows analysts to interact with and analyze the uncertainty information at different levels of detail. Three experiments were conducted to demonstrate the effectiveness and intuitiveness of our design.

  12. Flow Generated by an Aerated Rushton Impeller: Two-phase PIV Experiments and Numerical Simulations

    NARCIS (Netherlands)

    Deen, Niels G.; Solberg, Tron; Hjertager, H.

    2002-01-01

    A two-camera PIV technique was used to obtain angle resolved velocity and turbulence data of the flow in a lab-scale stirred tank, equipped with a Rushton turbine. Two cases were investigated: a single-phase flow and a gas-liquid flow. In the former case, the classical radial jet flow pattern accomp

  13. Flow generated by an aerated rushton impeller: two-phase PIV experiments and numerical simulations

    NARCIS (Netherlands)

    Deen, N.G.; Solberg, Tron; Hjertager, H.

    2002-01-01

    A two-camera PIV technique was used to obtain angle resolved velocity and turbulence data of the flow in a lab-scale stirred tank, equipped with a Rushton turbine. Two cases were investigated: a single-phase flow and a gas-liquid flow. In the former case, the classical radial jet flow pattern accomp

  14. Aeration equipment for small depths

    Science.gov (United States)

    Sluše, Jan; Pochylý, František

    2015-05-01

    Deficit of air in water causes complications with cyanobacteria mainly in the summer months. Cyanobacteria is a bacteria that produces poison called cyanotoxin. When the concentration of cyanobacteria increases, the phenomena "algal bloom" appears, which is very toxic and may kill all the organisms. This article describes new equipment for aeration of water in dams, ponds and reservoirs with small depth. This equipment is mobile and it is able to work without any human factor because its control is provided by a GPS module. The main part of this equipment consists of a floating pump which pumps water from the surface. Another important part of this equipment is an aerator where water and air are blended. Final aeration process runs in the nozzles which provide movement of all this equipment and aeration of the water. Simulations of the flow are solved by multiphase flow with diffusion in open source program called OpenFOAM. Results will be verified by an experiment.

  15. Analytical solutions of moisture flow equations and their numerical evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Gibbs, A.G.

    1981-04-01

    The role of analytical solutions of idealized moisture flow problems is discussed. Some different formulations of the moisture flow problem are reviewed. A number of different analytical solutions are summarized, including the case of idealized coupled moisture and heat flow. The evaluation of special functions which commonly arise in analytical solutions is discussed, including some pitfalls in the evaluation of expressions involving combinations of special functions. Finally, perturbation theory methods are summarized which can be used to obtain good approximate analytical solutions to problems which are too complicated to solve exactly, but which are close to an analytically solvable problem.

  16. Interdependences between flow patterns and oxygen entry in aeration tanks of wastewater treatment plants; Der Zusammenhang von Stroemungsstrukturen und Sauerstoffeintrag bei druckbeluefteten Belebungsbecken

    Energy Technology Data Exchange (ETDEWEB)

    Thiersch, B.

    2001-07-01

    The flow field, turbulence intensities and the distribution of the relative gas-holdup of aeration tanks of operating wastewater treatment plants were investigated experimentally with Acoustic-Doppler-Velocimeter probes. Based on the experimental results a hydrodynamical model in Euler-Euler-Formulation was developed and numerical studies of different tank and diffuser arrangements were performed. It was found that the flow pattern is mainly influenced by the gas sparger arrangement and the tank aspect-ratio. Combining the experimental and numerical results reasons for different aeration efficiencies were identified. Increasing the diffuser density changed the flow field from the spiral type to the cellular pattern with instable and dynamical structures. These flow patterns improved the aeration efficiency by increasing the residence time of the bubbles and the recirculating flows. (orig.) [German] In der vorliegenden Arbeit werden grundlegende Stroemungsstrukturen von druckbeluefteten Belebungsbecken anhand messtechnischer Untersuchungen der Geschwindigkeitsverteilungen, Turbulenzgroessen und relativer Gasgehaltsverteilungen von Belebungsbecken im Betriebszustand aufgezeigt. Vorab wird die Einsatzfaehigkeit von Akkustik-Doppler-Sonden in dispersen Zweiphasenstroemungen detailliert ueberprueft. Aufbauend auf den Messergebnissen wird ein numerisches Simulationsprogramm zur dynamischen Berechnung unterschiedlicher Beckenkonfigurationen entwickelt. Aus den experimentellen Ergebnissen in Verbindung mit den Berechnungsergebnissen sowie den Auswertungen frueherer Untersuchungen konnten hydromechanische Ursachen der unterschiedlichen Sauerstoffeintragseffizienz bei verschiedenen Beckenkonzeptionen abgeleitet werden. Dabei stellen die Anordnung sowie Gleichverteilung der Belueftungselemente sowie das Querschnittsverhaeltnis der Belebungsbecken die wesentlichen Einflussgroessen auf die Ausbildung der Stroemungsstrukturen dar. Mit zunehmender Belegungsdichte und

  17. Frontier in nanoscale flows fractional calculus and analytical methods

    CERN Document Server

    Lewis, Roland; Liu, Hong-yan

    2014-01-01

    This ebook covers the basic properties of nanoscale flows, and various analytical and numerical methods for nanoscale flows and environmental flows. This ebook is a good reference not only for audience of the journal, but also for various communities in mathematics, nanotechnology and environmental science.

  18. Study of the liquid-film-forming apparatus as an alternative aeration system: design criteria and operating condition.

    Science.gov (United States)

    Hongprasith, Narapong; Imai, Tsuyoshi; Painmanakul, Pisut

    2017-06-01

    Aeration is an important factor in aquaculture systems because it is a vital condition for all organisms that live in water and respire aerobically. Generally, mechanical surface aerators are widely used in Thailand due to their advantage for increasing dissolved oxygen (DO) and for their horizontal mixing of aquaculture ponds with large surface areas. However, these systems still have some drawbacks, primarily the low oxygen transfer efficiency (OTE) and energy. Regarding this issue, alternative aeration systems should be studied and applied. Therefore, this research aims to study the aeration mechanism obtained by the diffused-air aeration combined with a liquid-film-forming apparatus (LFFA). The effect of gas flow rates, types, and patterns of aerator installation were investigated in an aquaculture pond of 10 m × 10 m × 1.5 m. The analytical parameters were volumetric mass transfer coefficient (kLa), OTE, and aeration efficiency (AE). From the results, the '4-D' with partitions was proposed as the suitable pattern for the LFFA installation. The advantage could be obtained from high energy performance with 1.2 kg/kW h of AE. Then, the operation conditions can be applied as a design guideline for this alternative aeration system in the aquaculture ponds.

  19. Analytical heat and fluid flow in microchannels and microsystems

    CERN Document Server

    Cotta, Renato M; Naveira-Cotta, Carolina P

    2016-01-01

    This book focuses on the modeling and analysis of heat and fluid flow in microchannels and micro-systems, compiling a number of analytical and hybrid numerical-analytical solutions for models that account for the relevant micro-scale effects, with the corresponding experimental analysis validation when applicable. The volume stands as the only available compilation of easy to use analytically-based solutions for micro-scale heat and fluid flow problems, that systematically incorporates the most relevant micro-scale effects into the mathematical models, followed by their physical interpretation on the micro-system behavior.

  20. Intermittent Aeration in Biological Treatment of Wastewater

    Directory of Open Access Journals (Sweden)

    H. Doan

    2009-01-01

    Full Text Available Problem statement: E-coating process is widely used to provide a protective coating layer on metal parts in the automotive and metal finishing industry. The wastewater from the coating process contains organic compounds that are used in the cleaning, pretreatment and coating steps. Organic pollutants can be removed biologically. In the aerobic biological treatment, water aeration accounts for a significant portion of the total operating cost of the treatment process. Intermittent aeration is thus of benefit since it would reduce the energy consumption in the wastewater treatment. In the present study, wastewater from an electro-coating process was treated biologically using a packed column as an aerator where the wastewater was aerated by a countercurrent air flow. The objective was to obtain an optimum aeration cycle. Approach: Intermittent aeration time was varied at different preset cycles. An operational optimum of the aeration time (or air-water contacting time in the column was determined from the BOD5 removal after a certain treatment period. For continuous aeration of the wastewater, the air-liquid contacting time in the column was 52 min for 24 h of treatment. A unit energy consumption for pumping liquid and air, which was defined as the energy consumption per percent BOD5 removed, was used as a criterion to determine the optimum contacting time. Results: Optimum air-liquid contacting times were found to be about 38, 26 and 22 min for the treatment times of 24, 48 and 72 h, consecutively. This indicates that 27-58% saving on the unit energy consumption can be achieved using intermittent aeration of the wastewater. On the basis of the overall BOD5 removal, 17% and 23% savings in energy were observed with the intermittent aeration as compared to the continuous aeration of the wastewater for 48 and 72 h. Conclusion: The results obtained indicate that an appropriate intermittent aeration cycle can bring about a substantial energy saving

  1. An analytical theory of heated duct flows in supersonic combustors

    Directory of Open Access Journals (Sweden)

    Chenxi Wu

    2014-01-01

    Full Text Available One-dimensional analytical theory is developed for supersonic duct flow with variation of cross section, wall friction, heat addition, and relations between the inlet and outlet flow parameters are obtained. By introducing a selfsimilar parameter, effects of heat releasing, wall friction, and change in cross section area on the flow can be normalized and a self-similar solution of the flow equations can be found. Based on the result of self-similar solution, the sufficient and necessary condition for the occurrence of thermal choking is derived. A relation of the maximum heat addition leading to thermal choking of the duct flow is derived as functions of area ratio, wall friction, and mass addition, which is an extension of the classic Rayleigh flow theory, where the effects of wall friction and mass addition are not considered. The present work is expected to provide fundamentals for developing an integral analytical theory for ramjets and scramjets.

  2. Cavity length below chute aerators

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    It is proved that air entrainment is one of the efficient measures dealing with cavi-tation control for the release works of hydropower projects. There are many factors to be considered in designing a chute aerator. One of the most important factors concerns the cavity length below the aerator,which has outstanding effects on air entrainment against cavitation damage. It is crucial to determine reasonable emergence angle for the calculation of the cavity length. In the present paper the overall effects of structural and hydraulic parameters on the emergence angle of the flow from the aerator were analyzed. Four improved expressions of the emer-gence angle with weight coefficient were investigated through experimental data of 68 points observed from 12 aerators of 6 hydropower projects,of both model and prototype,on the basis of error theory. A method to calculate the cavity length be-low aerators was suggested,which considers overall effects of the above men-tioned parameters. Comparison between the method in this paper and the other five methods of calculating the cavity length showed that the present method is much more reliable than the existing methods while the mean error of the method is less than others.

  3. Cavity length below chute aerators

    Institute of Scientific and Technical Information of China (English)

    WU JianHua; RUAN ShiPing

    2008-01-01

    It is proved that air entrainment is one of the efficient measures dealing with cavitation control for the release works of hydropower projects. There are many factors to be considered in designing a chute aerator. One of the most important factors concerns the cavity length below the aerator, which has outstanding effects on air entrainment against cavitation damage. It is crucial to determine reasonable emergence angle for the calculation of the cavity length. In the present paper the overall effects of structural and hydraulic parameters on the emergence angle of the flow from the aerator were analyzed. Four improved expressions of the emergence angle with weight coefficient were investigated through experimental data of 68 points observed from 12 aerators of 6 hydropower projects, of both model and prototype, on the basis of error theory. A method to calculate the cavity length below aerators was suggested, which considers overall effects of the above mentioned parameters. Comparison between the method in this paper and the other five methods of calculating the cavity length showed that the present method is much more reliable than the existing methods while the mean error of the method is less than others.

  4. HYDRAULIC RESEARCH OF AERATORS ON TUNNEL SPILLWAYS

    Institute of Scientific and Technical Information of China (English)

    RUAN Shi-ping; WU Jian-hua; WU Wei-wei; XI Ru-ze

    2007-01-01

    The selection of the configuration and size of an aerator was of importance for a tunnel spillway under the conditions of high speed flows. Experimental investigations were conducted on the effects of entrained air on the tunnel spillway in the Goupitan Project, based on the criterion of gravity similarity and the condition of aerated flow velocity of over 6 m/s, with physical models. The configurations of the aerators were presented of a larger bottom air concentration, to protect the tunnel spillway from cavitation as well as to see no water fills in the grooves.

  5. Analytical Solution for Isentropic Flows in Solids

    Science.gov (United States)

    Heuzé, Olivier

    2009-12-01

    In the XIXth century, Riemann gave the equations system and the exact solution for the isentropic flows in the case of the ideal gas. But to our knowledge, nothing has been done to apply it to condensed media. Many materials of practical interest, for instance metals, obey to the linear law D = c+s u, where D is the shock velocity, u the particle velocity, and c and s properties of the material. We notice that s is strongly linked to the fundamental derivative. This means that the assumption of constant fundamental derivative is useful in this case, as it was with the isentropic gamma in the Riemann solution. Then we can apply the exact Riemann solution for these materials. Although the use of the hypergeometric function is complicated in this case, we obtain a very good approximation with the development in power series.

  6. Ultrasonic analyte concentration and application in flow cytometry

    Energy Technology Data Exchange (ETDEWEB)

    Kaduchak, Gregory; Goddard, Greg; Salzman, Gary; Sinha, Dipen; Martin, John C.; Kwiatkowski, Christopher; Graves, Steven

    2015-07-07

    The present invention includes an apparatus and corresponding method for concentrating analytes within a fluid flowing through a tube using acoustic radiation pressure. The apparatus includes a function generator that outputs a radio frequency electrical signal to a transducer that transforms the radio frequency electric signal to an acoustic signal and couples the acoustic signal to the tube. The acoustic signal is converted within the tube to acoustic pressure that concentrates the analytes within the fluid.

  7. Ultrasonic analyte concentration and application in flow cytometry

    Energy Technology Data Exchange (ETDEWEB)

    Kaduchak, Gregory; Goddard, Greg; Salzman, Gary; Sinha, Dipen; Martin, John C.; Kwiatkowski, Christopher; Graves, Steven

    2014-07-22

    The present invention includes an apparatus and corresponding method for concentrating analytes within a fluid flowing through a tube using acoustic radiation pressure. The apparatus includes a function generator that outputs a radio frequency electrical signal to a transducer that transforms the radio frequency electric signal to an acoustic signal and couples the acoustic signal to the tube. The acoustic signal is converted within the tube to acoustic pressure that concentrates the analytes within the fluid.

  8. Ultrasonic analyte concentration and application in flow cytometry

    Science.gov (United States)

    Kaduchak, Gregory; Goddard, Greg; Salzman, Gary; Sinha, Dipen; Martin, John C.; Kwiatkowski, Christopher; Graves, Steven

    2008-03-11

    The present invention includes an apparatus and corresponding method for concentrating analytes within a fluid flowing through a tube using acoustic radiation pressure. The apparatus includes a function generator that outputs a radio frequency electrical signal to a transducer that transforms the radio frequency electric signal to an acoustic signal and couples the acoustic signal to the tube. The acoustic signal is converted within the tube to acoustic pressure that concentrates the analytes within the fluid.

  9. Analytical methods for heat transfer and fluid flow problems

    CERN Document Server

    Weigand, Bernhard

    2015-01-01

    This book describes useful analytical methods by applying them to real-world problems rather than solving the usual over-simplified classroom problems. The book demonstrates the applicability of analytical methods even for complex problems and guides the reader to a more intuitive understanding of approaches and solutions. Although the solution of Partial Differential Equations by numerical methods is the standard practice in industries, analytical methods are still important for the critical assessment of results derived from advanced computer simulations and the improvement of the underlying numerical techniques. Literature devoted to analytical methods, however, often focuses on theoretical and mathematical aspects and is therefore useless to most engineers. Analytical Methods for Heat Transfer and Fluid Flow Problems addresses engineers and engineering students. The second edition has been updated, the chapters on non-linear problems and on axial heat conduction problems were extended. And worked out exam...

  10. Analytic solutions for unconfined groundwater flow over a stepped base

    Science.gov (United States)

    Fitts, Charles R.; Strack, Otto D. L.

    1996-03-01

    Two new exact solutions are presented for uniform unconfined groundwater flow over a stepped base; one for a step down in the direction of flow, the other for a step up in the direction of flow. These are two-dimensional solutions of Laplace's equation in the vertical plane, and are derived using the hodograph method and conformal mappings on Riemann surfaces. The exact solutions are compared with approximate one-dimensional solutions which neglect the resistance to vertical flow. For small horizontal hydraulic gradients typical of regional groundwater flow, little error is introduced by neglecting the vertical resistance to flow. This conclusion may be extended to two-dimensional analytical models in the horizontal plane, which neglect the vertical resistance to flow and treat the aquifer base as a series of flat steps.

  11. Analytical solution for inviscid flow inside an evaporating sessile drop

    OpenAIRE

    Masoud, Hassan; Felske, James D.

    2008-01-01

    Inviscid flow within an evaporating sessile drop is analyzed. The field equation, E^2(Psi)=0, is solved for the stream function. The exact analytical solution is obtained for arbitrary contact angle and distribution of evaporative flux along the free boundary. Specific results and computations are presented for evaporation corresponding to both uniform flux and purely diffusive gas phase transport into an infinite ambient. Wetting and non-wetting contact angles are considered with flow patter...

  12. Analytic expression for poloidal flow velocity in the banana regime

    Energy Technology Data Exchange (ETDEWEB)

    Taguchi, M. [College of Industrial Technology, Nihon University, Narashino 275-8576 (Japan)

    2013-01-15

    The poloidal flow velocity in the banana regime is calculated by improving the l = 1 approximation for the Fokker-Planck collision operator [M. Taguchi, Plasma Phys. Controlled Fusion 30, 1897 (1988)]. The obtained analytic expression for this flow, which can be used for general axisymmetric toroidal plasmas, agrees quite well with the recently calculated numerical results by Parker and Catto [Plasma Phys. Controlled Fusion 54, 085011 (2012)] in the full range of aspect ratio.

  13. An Analytical Model of Wake Deflection Due to Shear Flow

    NARCIS (Netherlands)

    Micallef, D.; Simao Ferreira, C.J.; Sant, T.; Van Bussel, G.J.W.

    2010-01-01

    The main motivation behind this work is to create a purely analytical engineering model for wind turbine wake upward deflection due to shear flow, by developing a closed form solution of the velocity field due to an oblique vortex ring. The effectiveness of the model is evaluated by comparing the re

  14. Flow Injection Analysis: A Revolution in Modern Analytical Chemistry

    DEFF Research Database (Denmark)

    Hansen, Elo Harald

    1996-01-01

    A review is made of the fundamentals of Flow Injection Analysis (FIA), and the versatility and applicability of this analytical concept is demonstrated by a series of examples, comprizing the use of different types of FIA-manifolds and various detection devices (optical and electrochemical). Emph...

  15. Analytical model of interaction of tide and river flow

    Directory of Open Access Journals (Sweden)

    Phairot Chatanantavet

    2006-11-01

    Full Text Available Hydrodynamic characteristics of a river resulting from interaction of tide and river flow are important since problems regarding flood, salinity intrusion, water quality and sedimentation are ubiquitous. The lower reach of the river strongly influenced by tides from the sea, when interacting with river flows, results in a complicated pattern which is simplified to its interaction with four main constituents of tides obtained from harmonic analysis. An analytical model is developed in this study for simulating the hydrodynamic processes in estuarine waters, with the emphasis being given to the interaction between tides and river flows. The perturbation method is used to derive the analytical solution, in which the estuarine flow is separated into steady and unsteady components. Thus the analytical solutions derived consist of two distinct parts; one represents the influence of river flows and the other represents the influence of tides. The application of the model to a case study, the Chao Phraya river, which requires a time series of discharges and loadings at the river mouth to model water quality in the Gulf of Thailand, shows that the model can beautifully and completely simulate the hydrodynamic features of tide and river flow interaction especially in the rainy season when the river discharge is high. Data of tidal discharges are scarce because of high cost of measurement especially in the lower reach of the river strongly influenced by tides from the sea. From this study of relation between tidal discharges and tides, the analytical model can compute tidal discharges from tides correctly. The results of tides and tidal flow can subsequently be used to calculate eddy viscosity and dispersion coefficient for describing salinity and water quality profiles.

  16. Following analytically stages of transition in Couette flow

    Science.gov (United States)

    Karp, Michael; Cohen, Jacob

    2013-11-01

    A possible explanation for transition in Couette flow is the mechanism of transient growth (TG). Accordingly, a small disturbance can achieve a significant non-modal TG and trigger nonlinear mechanisms before its eventual decay owing to viscosity. The linear optimal disturbance achieving the maximal growth consists of a pair of streamwise independent counter-rotating vortices (CVPs) which create spanwise-varying streamwise streaks. These may become unstable with respect to infinitesimal disturbances. It is shown that four decaying normal modes, obtained analytically, are sufficient to follow the linear TG mechanism. A secondary linear stability analysis of the modified base-flow (Couette flow with streaks) is conducted using Floquet theory for the spanwise periodic base-flow. The predictions of the stability analysis are compared with direct numerical simulations using the ``Channelflow'' code. It is shown analytically that the inclusion of nonlinear interactions between the base-flow and the CVPs is required in order to predict instability. Furthermore, it is demonstrated that the generation of a `strong' inflectional point is more important than obtaining maximal growth. The minimal number of modes enables us to follow analytically several key stages of the transition process.

  17. Analytical effective tensor for flow-through composites

    Science.gov (United States)

    Sviercoski, Rosangela De Fatima

    2012-06-19

    A machine, method and computer-usable medium for modeling an average flow of a substance through a composite material. Such a modeling includes an analytical calculation of an effective tensor K.sup.a suitable for use with a variety of media. The analytical calculation corresponds to an approximation to the tensor K, and follows by first computing the diagonal values, and then identifying symmetries of the heterogeneity distribution. Additional calculations include determining the center of mass of the heterogeneous cell and its angle according to a defined Cartesian system, and utilizing this angle into a rotation formula to compute the off-diagonal values and determining its sign.

  18. Inverse problem of bottom slope design for aerator devices

    Institute of Scientific and Technical Information of China (English)

    吴建华; 樊博; 许唯临

    2013-01-01

    Air entrainment is an effective approach to protect release works from cavitation damage. The traditional method of aera-tor device designs is that, for given flow conditions, the geometries of the aerator device are designed and then the effects are experi-mentally tested for cavitation damage control. The present paper proposes an inverse problem method of determining the bottom slopes in front of and behind an aerator if the requirements of air entrainment, flow conditions and some of aerator geometric para-meters are given. An RBF neural network model is developed and the relevant bottom slopes are calculated in different conditions of flow and geometry on the basis of the data of 19 aerator devices from different discharge tunnels with safe operation. The case study shows that the methodology provides an effective way to design aerator devices under given target conditions.

  19. Experimental study on the distribution of air concentration in flow after bottom aerator%泄槽底部掺气坎后水流掺气浓度分布模型试验

    Institute of Scientific and Technical Information of China (English)

    马关博; 徐一民; 乔梁; 荣岩

    2014-01-01

    针对泄槽底部掺气坎后的掺气浓度分布规律较为复杂、研究成果较少的问题,为了更清楚地探究泄槽底部掺气坎后上游直段、反弧段及下游直段水流掺气浓度分布规律,采用含有反弧段的泄槽进行模型试验研究。试验结果表明:上游直段、反弧段及下游直段水流中不同水深处掺气浓度的沿程变化规律是不相同的;其他条件不变时,水流掺气浓度随掺气坎高度的增加而增大,随反弧段反弧半径的减小而减小;掺气坎高度和反弧半径对掺气设施的有效保护范围有一定的影响,适当提高掺气坎的高度和反弧段的半径对增大掺气设施的有效保护长度有利。%Setting an aerator on the chute contained ogee section is an important subject of cavitation erosion. The distribution of air concentration in flow after bottom aerator still a challenge task and relevant research results are quite limited. In order to explore the distribution of air concentration on straight section after aerator, ogee section, and straight section after ogee section on chute, we use the chute with ogee section to set up an experiment. By doing it so, different size of aerator with different radius of ogee section have been tested, measured rand analyzed. The overall experiment results show that when other conditions remain unchanged, the air concentration in the flow increases with the increase of aerator's height and decreases with the decrease of the anti-arc radius of the chute. According to the air concentration in the flow, the length of protective segment of the chute may vary with aerator's height and the radius of anti-arc of the chute. To some extent, increasing aerator's height and the anti-arc radius of the flow chute can prolong the length of protective segment.

  20. USING AERATION FOR CORROSION CONTROL

    Science.gov (United States)

    Aeration is a useful drinking water treatment process. Aeration has been used to remove hydrogen sulfide, methane, radon, iron, manganese, and volatile organic contaminants (VOCs) from drinking water. Aeration is also effective in removing carbon dioxide which directly impacts ...

  1. FLOW RESISTANCE THROUGH HORIZONTAL ORIFICE OF LOOP SEAL WITH SIDE AERATION AIR%有侧吹风环流料封阀水平孔口流动阻力特性

    Institute of Scientific and Technical Information of China (English)

    王擎; 孙东红; 孙键; 骆仲泱; 岑可法; 秦裕琨

    2000-01-01

    By using a cold CFB model, the effect of horizontal orifice areas of Loop Seal with side aeration air on operational property was studied in detail.The results showed that the horizontal orifice area had a great effect on its stable operation and regulation of the recirculation rate.Under a certain range of the horizontal orifice area,the stable flow of solid particles through Loop Seal could be obtained and recirculation rate of solid particles could be well regulated and controlled through changing external aeration.The flow resistance properties across the horizontal orifice were given and an empirical equation of the pressure drop of horizontal orifice and solid circulating flow rate was proposed and a new orifice discharge coefficient was defined.The expression's were in good agreement with the experimental data.

  2. Sawdust discharge rate from aerated hoppers

    Institute of Scientific and Technical Information of China (English)

    Pan Chen; Zhulin Yuan; Chien-Song Chyang; Fu-Xiong Zhuan

    2011-01-01

    This paper presents a numerical and experimental study of the discharge rate of sawdust from an aerated hopper as an important parameter in many industrial processes involving the handling of other granular materials. Numerical experiments are conducted by means of an Eulerian-Eulerian approach coupled with the kinetic theory of granular flow (KTGF). Emphasis is given to the effects of particle size, hopper outlet width, hopper half angle, aeration height and air flow rate. The results show that the discharge rate is significantly affected by hopper outlet width, particle size and air flow rate, but is not sensitive to the hopper half angle and aeration height: increasing hopper outlet width or air flow rate increases discharge rate, while increasing particle size decreases discharge rate. Close agreement between numerical predictions and experimental results is obtained.

  3. Analytical Tools to Improve Optimization Procedures for Lateral Flow Assays

    Directory of Open Access Journals (Sweden)

    Helen V. Hsieh

    2017-05-01

    Full Text Available Immunochromatographic or lateral flow assays (LFAs are inexpensive, easy to use, point-of-care medical diagnostic tests that are found in arenas ranging from a doctor’s office in Manhattan to a rural medical clinic in low resource settings. The simplicity in the LFA itself belies the complex task of optimization required to make the test sensitive, rapid and easy to use. Currently, the manufacturers develop LFAs by empirical optimization of material components (e.g., analytical membranes, conjugate pads and sample pads, biological reagents (e.g., antibodies, blocking reagents and buffers and the design of delivery geometry. In this paper, we will review conventional optimization and then focus on the latter and outline analytical tools, such as dynamic light scattering and optical biosensors, as well as methods, such as microfluidic flow design and mechanistic models. We are applying these tools to find non-obvious optima of lateral flow assays for improved sensitivity, specificity and manufacturing robustness.

  4. Influence of oxygen flow rate and compost addition on reduction of organic matter in aerated waste layer containing mainly incineration residue

    Institute of Scientific and Technical Information of China (English)

    Hiroshi Asakrura; Kei Nakagawa; Kazuto Endo; Masato Yamada; Yusaku Ono; Yoshiro Ono

    2013-01-01

    Landfilling municipal solid waste incineration (MSWI) residue alkalizes the waste layer,causing a subsequent decrease in microbial activity and a delay in the decomposition of organic matter.In this study,efficiencies of neutralization of the leachate and organic matter decomposition in the waste layer in a column filled with MSWI residue using aeration and compost addition were evaluated.Total organic carbon (TOC) reduction in the waste layer is large at high oxygen flow rate (OFR).To effectively accelerate TOC reduction in the waste layer to which compost was added,a high OFR exceeding that by natural ventilation was required.At day 65,the pH of the leachate when OFR was above 102 mol-O2/(day·m3) was lower than that when OFR was below 101 mol-O2/(day·m3).At the same OFR,the pH of waste sample was lower than that of waste sample with compost.Although leachate neutralization could be affected by compost addition,TOC reduction in the waste layer became rather small.It is possible that humic substances in compost prevent the decomposition of TOC in MSWI residue.

  5. The Up-Flow Biological Aerated Filter (UFBAF) process in treating mixed (urban and industrial) sewage. Its performance in a pilot plant; Proceso de biofiltracion Up-Flow Biological Aerated Filter-UFBAF para el tratamiento de aguas residuales mixtas (urbanas e industriales). Rendimientos en planta piloto

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-07-01

    The Up-Flow Biological Aerated Filter (UFBAF) process is a variant on the conventional activated sludge process. It is based on a greater sludge density, as the sludge sticks to expanded clay balls of between 3 and 6 mm in diameter. A trial of this process was conducted using a pilot plant whose main components were a bio filter for eliminating organic matter and a single layer filter for eliminating the solids left over from the bio filter. the effluent employed in the trial was waste water that had been pretreated by sieving and primary decanting. The main object of these trials was to determine the capacity and limits of the treatment in eliminating organic matter under overload conditions in order to determine the recovery time required to return to normal operation. (Author) 3 refs.

  6. Analytical solution for inviscid flow inside an evaporating sessile drop.

    Science.gov (United States)

    Masoud, Hassan; Felske, James D

    2009-01-01

    Inviscid flow within an evaporating sessile drop is analyzed. The field equation E;{2}psi=0 is solved for the stream function. The exact analytical solution is obtained for arbitrary contact angle and distribution of evaporative flux along the free boundary. Specific results and computations are presented for evaporation corresponding to both uniform flux and purely diffusive gas phase transport into an infinite ambient. Wetting and nonwetting contact angles are considered, with flow patterns in each case being illustrated. The limiting behaviors of small contact angle and droplets of hemispherical shape are treated. All of the above categories are considered for the cases of droplets whose contact lines are either pinned or free to move during evaporation.

  7. Numerical and Analytical Study of Bladder-Collapse Flow

    Directory of Open Access Journals (Sweden)

    M. Tziannaros

    2012-01-01

    Full Text Available Understanding and quantifying more of the workings of the human bladder motivates the present industry-supported study. The bladder performance in terms of the urinary velocities produced tends to be dominated by the internal fluid dynamics involved, in the sense that the bladder wall moves in a body-prescribed way. The enclosed urine flow responds to this wall movement, and there is relatively little feedback on the wall movement. Combined computational work and special-configuration analysis are applied over a range of configurations including computational and analytical results for the circle and sphere as basic cases; models of more realistic bladder shapes; the end stage of the micturition process where the bladder is relatively squashed down near the urethral sphincter and localised peak speeds arise. The combination of approaches above can be extended to allow for interaction between wall shape and flow properties such as internal pressure if necessary.

  8. Flow harmonics within an analytically solvable viscous hydrodynamic model

    CERN Document Server

    Hatta, Yoshitaka; Torrieri, Giorgio; Xiao, Bo-Wen

    2014-01-01

    Based on a viscous hydrodynamic model with anisotropically perturbed Gubser flow and isothermal Cooper-Frye freezeout, we analytically compute the flow harmonics $v_n(p_T)$ and study how they scale with the harmonic number $n$ and transverse momentum, as well as the system size, shear and bulk viscosity coefficients, and collision energy. In particular, we find that the magnitude of shear viscous corrections grows linearly with $n$. The mixing between different harmonics is also discussed. While this model is rather simple as compared to realistic heavy-ion collisions, we argue that the scaling results presented here may be meaningfully compared to experimental data collected over many energies, system sizes, and geometries.

  9. EFFECT OF AERATOR ON HYDRAULIC DRAG ACTING ON A CHUTE

    Institute of Scientific and Technical Information of China (English)

    NI Han-gen; LI Xin; ZHOU Jing; JIN Qiao

    2005-01-01

    The formulae used to calculate the friction in the non-uniform flow chute were examined with the experimental data, and the results show that the accuracy of the formula is enough for engineering applications. A comparison between the results of friction respectively from the uniform flow assumption and the non-uniform flow approximation indicates that the former is an order of magnitude larger than the latter in the case of steep chute. The hydraulic drag on a steep chute with aerators was measured on the hydraulic model directly and the coefficient of the aerator effect on the drag was obtained. The variation patterns of the wall shear just downstream of the aerators were investigated and the mechanism of the increase in the drag by aerator were analyzed qualitatively with the measured water-depths just downstream the aerators.

  10. A compressible two-fluid model for the finite volume simulation of violent aerated flows. Analytical properties and numerical results

    CERN Document Server

    Dias, Frédéric; Ghidaglia, Jean-Michel

    2008-01-01

    In the study of ocean wave impact on structures, one often uses Froude scaling since the dominant force is gravity. However the presence of trapped or entrained air in the water can significantly modify wave impacts. When air is entrained in water in the form of small bubbles, the acoustic properties in the water change dramatically and for example the speed of sound in the mixture is much smaller than in pure water, and even smaller than in pure air. While some work has been done to study small-amplitude disturbances in such mixtures, little work has been done on large disturbances in air-water mixtures. We propose a basic two-fluid model in which both fluids share the same velocities. It is shown that this model can successfully mimic water wave impacts on coastal structures. Even though this is a model without interface, waves can occur. Their dispersion relation is discussed and the formal limit of pure phases (interfacial waves) is considered. The governing equations are discretized by a second-order fin...

  11. Impact of artificial aeration on nitrogen removal from aquaculture wastewater treated by vertical-flow constructed wetland%曝气对垂直流湿地处理水产养殖废水脱氮的影响

    Institute of Scientific and Technical Information of China (English)

    张世羊; 常军军; 高毛林; 李谷

    2015-01-01

    人工湿地作为一种有效的污水处理技术,现已被逐渐拓展到水产养殖业中。鉴于其与养殖竞争有限土地资源的弊端,如何构建节地高效型湿地成为未来研究的重点。曝气增氧是强化潜流湿地净化效能的重要措施之一,但是关于曝气强度以及净化效率与影响因素的关系仍缺乏深入系统的研究。为此,该文设计构建了7组不同要素组合的垂直流湿地小试系统,同步或分阶段探讨了曝气强化对垂直流湿地脱氮的影响。研究结果表明,无论曝气与否,构建的7组湿地系统于试验运行工况下都存在明显的硝化过程,且空气复氧和植物根系泌氧足以弥补硝化作用耗氧量。曝气增氧进一步强化了湿地内部的矿化和硝化过程;鉴于养殖废水不缺乏碳源(该研究各组湿地进水碳氮比在28.4~30.6之间),湿地内部的反硝化几率增大,导致曝气后总氮的去除效率提高。但是曝气条件下过高的溶解氧又会进一步抑制反硝化过程,从而也会导致系统总氮去除速率的下降。因此,对垂直流湿地而言,曝气强度不是愈高愈好。为了获得更高的脱氮效率,建议可以通过延长水力停留时间或者在垂直流湿地尾部增设水平潜流湿地来补充反硝化过程,进而提高系统对总氮的去除效果。%Due to the serious trend of water pollution across the country, the problem of aquaculture wastewater discharge must be solved appropriately to achieve sustainability. As a novel technology for sewage treatment, constructed wetland (CW) has been gradually expanded to aquaculture. In view of the disadvantages in land dispute with pond aquaculture, how to develop or design a land-saving, high-efficiency CW will be the focus of future study. It is widely accepted that artificial aeration can enhance the purification efficiency of CW’s subsurface flow on wastewater due to its capacity to improve

  12. Enhancement of ultrasonic disintegration of sewage sludge by aeration.

    Science.gov (United States)

    Zhao, He; Zhang, Panyue; Zhang, Guangming; Cheng, Rong

    2016-04-01

    Sonication is an effective way for sludge disintegration, which can significantly improve the efficiency of anaerobic digestion to reduce and recycle use of sludge. But high energy consumption limits the wide application of sonication. In order to improve ultrasonic sludge disintegration efficiency and reduce energy consumption, aeration was introduced. Results showed that sludge disintegration efficiency was improved significantly by combining aeration with ultrasound. The aeration flow rate, gas bubble size, ultrasonic density and aeration timing had impacts on sludge disintegration efficiency. Aeration that used in later stage of ultrasonic irradiation with low aeration flow rate, small gas bubbles significantly improved ultrasonic disintegration sludge efficiency. At the optimal conditions of 0.4 W/mL ultrasonic irradiation density, 30 mL/min of aeration flow rate, 5 min of aeration in later stage and small gas bubbles, ultrasonic sludge disintegration efficiency was increased by 45% and one third of ultrasonic energy was saved. This approach will greatly benefit the application of ultrasonic sludge disintegration and strongly promote the treatment and recycle of wastewater sludge.

  13. Aerated bunker discharge of fine dilating powders

    NARCIS (Netherlands)

    Ouwerkerk, C.E.D.; Molenaar, H.J.; Frank, M.J.W.

    1992-01-01

    The discharge rate of coarse powders (mean particle size 500 ¿m) from bunkers without aeration can be described by both empirical relations and theoretical models. In the case of small particles the discharge rate is largely overestimated. As the powder dilates during flow a negative pressure gradie

  14. 气泡尺寸对曝气池内气液两相流数值模拟的影响%Influence of the bubble size on numerical simulation of the gas-liquid flow in aeration tanks

    Institute of Scientific and Technical Information of China (English)

    肖柏青; 张法星; 戎贵文

    2012-01-01

    In order to explore the influence of bubble size on numerical simulation of gas-liquid two-phase flow in aeration tanks, a mathematical model for two-phase flow in aeration tanks was established using large-eddy simulation and Eulerian-Lagrangian approach. Based on the measured bubble size distribution produced by a commonly used membrane diffuser in model experiments, three kinds of bubble size set schemes in numerical simulation were designed. The effect of the different set schemes on the calculation of the flow velocity and gas holdup was studied. Bubble size had a great influence on the flow field in aeration tanks, and had little effect on the gas holdup distribution in most regions except the vicinity of the gas holdup peak; the input of bubble size using multiple size groups instead of a single group improved the prediction of two-phase flow in aeration tanks; when single bubble size was used, it should be as close to the average bubble diameter as possible.%为探索在曝气池气液两相流数值模拟中气泡尺寸对两相流流动特性的影响,采用大涡模拟和欧拉—拉格朗日方法建立了曝气池两相流数学模型.基于模型实验得到的工程上常用的微孔曝气盘的气泡尺寸分布,在数值模拟中设定了3种气泡尺寸分布方案,比较了不同的气泡尺寸设定方案对计算曝气池内水流流速和气含率等参数的影响.结果表明,气泡尺寸对水流流场具有较大的影响,而对气含率分布的影响在大部分区域不明显,只在气含率峰值附近影响较显著;使用多组气泡尺寸的设定方案可以提高计算结果的准确性,采用单组气泡尺寸时应尽量使其接近平均气泡直径.

  15. Comparison of Energy Dissipation with and without Aerators

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    Experimental results showed that aerators increase the energy dissipation of the flow in the channel by reducing the velocity coefficient φ in the deflector bucket and the jet-trajectory length, by increasing energy dissipation of the jet flow in the air and the diffusion length of the jet falling into the pool and by reducing the energy intensity of the jet falling into the pool. The energy dissipation prevents wash out downstream.When air is not entrained in the water flow, the aerators act as artificial irregularities in the channel. The energy dissipation due to the aerators in the channel without entrained air is greater than when air is entrained in the water flow.Correlations of the experimental data can be used to estimate the energy dissipation effect of the aerators on the outlet structure for the three test cases.

  16. Catfish production using intensive aeration

    Science.gov (United States)

    For the last 3 years, researchers at UAPB and NWAC have been monitoring and verifying production yields in intensively aerated catfish ponds with aeration rates greater than 6 hp/acre. We now have three years of data on commercial catfish production in intensively aerated ponds. With stocking densi...

  17. CAVITATION CONTROL BY AERATION AND ITS COMPRESSIBLE CHARACTERISTICS

    Institute of Scientific and Technical Information of China (English)

    DONG Zhi-yong; SU Pei-lan

    2006-01-01

    This paper presents an experimental investigation and a theoretical analysis of cavitation control by aeration and its compressible characteristics at the flow velocity V=20m/s-50m/s. Pressure waveforms with and without aeration in cavitation region were measured. The variation of compression ratio with air concentration was described, and the relation between the least air concentration to prevent cavitation erosion and flow velocity proposed based on our experimental study. The experimental results show that aeration remarkably increases the pressure in cavitation region, and the corresponding pressure wave exhibits a compression wave/shock wave. The pressure increase in cavitation region of high-velocity flow with aeration is due to the fact that the compression waves/shock wave after the flow is aerated. The compression ratio increases with air concentration rising. The relation between flow velocity and least air concentration to prevent cavitation erosion follows a semi-cubical parabola. Also, the speed of sound and Mach number of high-velocity aerated flow were analyzed.

  18. Supersonic Injection of Aerated Liquid Jet

    Science.gov (United States)

    Choudhari, Abhijit; Sallam, Khaled

    2016-11-01

    A computational study of the exit flow of an aerated two-dimensional jet from an under-expanded supersonic nozzle is presented. The liquid sheet is operating within the annular flow regime and the study is motivated by the application of supersonic nozzles in air-breathing propulsion systems, e.g. scramjet engines, ramjet engines and afterburners. The simulation was conducted using VOF model and SST k- ω turbulence model. The test conditions included: jet exit of 1 mm and mass flow rate of 1.8 kg/s. The results show that air reaches transonic condition at the injector exit due to the Fanno flow effects in the injector passage. The aerated liquid jet is alternately expanded by Prandtl-Meyer expansion fan and compressed by oblique shock waves due to the difference between the back (chamber) pressure and the flow pressure. The process then repeats itself and shock (Mach) diamonds are formed at downstream of injector exit similar to those typical of exhaust plumes of propulsion system. The present results, however, indicate that the flow field of supersonic aerated liquid jet is different from supersonic gas jets due to the effects of water evaporation from the liquid sheet. The contours of the Mach number, static pressure of both cases are compared to the theory of gas dynamics.

  19. Analytical Model of Water Flow in Coal with Active Matrix

    Science.gov (United States)

    Siemek, Jakub; Stopa, Jerzy

    2014-12-01

    This paper presents new analytical model of gas-water flow in coal seams in one dimension with emphasis on interactions between water flowing in cleats and coal matrix. Coal as a flowing system, can be viewed as a solid organic material consisting of two flow subsystems: a microporous matrix and a system of interconnected macropores and fractures. Most of gas is accumulated in the microporous matrix, where the primary flow mechanism is diffusion. Fractures and cleats existing in coal play an important role as a transportation system for macro scale flow of water and gas governed by Darcy's law. The coal matrix can imbibe water under capillary forces leading to exchange of mass between fractures and coal matrix. In this paper new partial differential equation for water saturation in fractures has been formulated, respecting mass exchange between coal matrix and fractures. Exact analytical solution has been obtained using the method of characteristics. The final solution has very simple form that may be useful for practical engineering calculations. It was observed that the rate of exchange of mass between the fractures and the coal matrix is governed by an expression which is analogous to the Newton cooling law known from theory of heat exchange, but in present case the mass transfer coefficient depends not only on coal and fluid properties but also on time and position. The constant term of mass transfer coefficient depends on relation between micro porosity and macro porosity of coal, capillary forces, and microporous structure of coal matrix. This term can be expressed theoretically or obtained experimentally. W artykule zaprezentowano nowy model matematyczny przepływu wody i gazu w jednowymiarowej warstwie węglowej z uwzględnieniem wymiany masy między systemem szczelin i matrycą węglową. Węgiel jako system przepływowy traktowany jest jako układ o podwójnej porowatości i przepuszczalności, składający się z mikroporowatej matrycy węglowej oraz z

  20. Analytical approach to continuous and intermittent bottleneck flows

    DEFF Research Database (Denmark)

    Helbing, D.; Johansson, A.; Mathiesen, Joachim Kaj;

    2006-01-01

    Many-particle-inspired theory, Continuous and Intermittent Bottleneck Flows Udgivelsesdato: Oct. 20......Many-particle-inspired theory, Continuous and Intermittent Bottleneck Flows Udgivelsesdato: Oct. 20...

  1. Optimum air-demand ratio for maximum aeration efficiency in high-head gated circular conduits.

    Science.gov (United States)

    Ozkan, Fahri; Tuna, M Cihat; Baylar, Ahmet; Ozturk, Mualla

    2014-01-01

    Oxygen is an important component of water quality and its ability to sustain life. Water aeration is the process of introducing air into a body of water to increase its oxygen saturation. Water aeration can be accomplished in a variety of ways, for instance, closed-conduit aeration. High-speed flow in a closed conduit involves air-water mixture flow. The air flow results from the subatmospheric pressure downstream of the gate. The air entrained by the high-speed flow is supplied by the air vent. The air entrained into the flow in the form of a large number of bubbles accelerates oxygen transfer and hence also increases aeration efficiency. In the present work, the optimum air-demand ratio for maximum aeration efficiency in high-head gated circular conduits was studied experimentally. Results showed that aeration efficiency increased with the air-demand ratio to a certain point and then aeration efficiency did not change with a further increase of the air-demand ratio. Thus, there was an optimum value for the air-demand ratio, depending on the Froude number, which provides maximum aeration efficiency. Furthermore, a design formula for aeration efficiency was presented relating aeration efficiency to the air-demand ratio and Froude number.

  2. Cavity filling water control below aerator devices

    Institute of Scientific and Technical Information of China (English)

    钱尚拓; 吴建华; 马飞; 徐建荣; 彭育; 汪振

    2014-01-01

    With the rapid development of high dam projects within China, the dragon-drop-tail spillway tunnel is introduced and widely used. In view of the high water head and the large flow velocity on the dragon-drop-tail section, aerator devices are usually placed for the cavitation damage control. For the device placed in its initial position, it is a serious concern to design a suitable flow regime of the cavity and to control the cavity filling water due to the large flow depth and the low Froude number through this aera-tor. In this study, the relationships between the geometries of the aerator device and the jet impact angle of the lower trajectory of the flow are theoretically analyzed with/without a local slope. Nine test cases with different geometries are designed, the effectiveness of the filling water control is experimentally investigated under different operation conditions, and two criteria of the local slope design are proposed. It is concluded that the cavity flow regime and the filling water can be improved if a small impact angle and some sui-table geometries of the local slope are designed.

  3. Intermittent aeration to improve wastewater treatment efficiency in pilot-scale constructed wetland.

    Science.gov (United States)

    Uggetti, Enrica; Hughes-Riley, Theodore; Morris, Robert H; Newton, Michael I; Trabi, Christophe L; Hawes, Patrick; Puigagut, Jaume; García, Joan

    2016-07-15

    Forced aeration of horizontal subsurface flow constructed wetlands (HSSF CWs) is nowadays a recognized method to improve treatment efficiency, mainly in terms of ammonium removal. While numerous investigations have been reported testing constant aeration, scarce information can be found about the efficiency of intermittent aeration. This study aims at comparing continuous and intermittent aeration, establishing if there is an optimal regime that will increase treatment efficiency of HSSF CWs whilst minimizing the energy requirement. Full and intermittent aeration were tested in a pilot plant of three HSSF CWs (2.64m(2) each) fed with primary treated wastewater. One unit was fully aerated; one intermittently aerated (i.e. by setting a limit of 0.5mg/L dissolved oxygen within the bed) with the remaining unit not aerated as a control. Results indicated that intermittent aeration was the most successful operating method. Indeed, the coexistence of aerobic and anoxic conditions promoted by the intermittent aeration resulted in the highest COD (66%), ammonium (99%) and total nitrogen (79%) removals. On the other hand, continuous aeration promotes ammonium removal (99%), but resulted in nitrate concentrations in the effluent of up to 27mg/L. This study demonstrates the high potential of the intermittent aeration to increase wastewater treatment efficiency of CWs providing an extreme benefit in terms of the energy consumption.

  4. An analytical model for annular flow boiling heat transfer in microchannel heat sinks

    Energy Technology Data Exchange (ETDEWEB)

    Megahed, A.; Hassan, I. [Concordia University, Montreal, QC (Canada). Dept. of Mechanical and Industrial Engineering

    2009-07-01

    An analytical model has been developed to predict flow boiling heat transfer coefficient in microchannel heat sinks. The new analytical model is proposed to predict the two-phase heat transfer coefficient during annular flow regime based on the separated model. Opposing to the majority of annular flow heat transfer models, the model is based on fundamental conservation principles. The model considers the characteristics of microchannel heat sink during annular flow and eliminates using any empirical closure relations. Comparison with limited experimental data was found to validate the usefulness of this analytical model. The model predicts the experimental data with a mean absolute error 8%. (author)

  5. Research on Aeration Systems Efficiency in Small Wastewater Treatment Plants

    OpenAIRE

    Ala Sokolova

    2011-01-01

    Large amount of small wastewater treatment plants does not work properly. One of the reasons could be wrong design of the aeration system. Therefore, the aim of this research is to analyse the performance of two aeration systems used in Lithuanian small wastewater treatment plants. Both aeration systems are designed for the following parameters: 4 PE and 0,8 m3/d wastewater flow. These data correspond to the oxygen requirement of 40,9 g O2/h. Summarizing the results of the research, it was fo...

  6. A new method for constructing analytic elements for groundwater flow.

    Science.gov (United States)

    Strack, O. D.

    2007-12-01

    The analytic element method is based upon the superposition of analytic functions that are defined throughout the infinite domain, and can be used to meet a variety of boundary conditions. Analytic elements have been use successfully for a number of problems, mainly dealing with the Poisson equation (see, e.g., Theory and Applications of the Analytic Element Method, Reviews of Geophysics, 41,2/1005 2003 by O.D.L. Strack). The majority of these analytic elements consists of functions that exhibit jumps along lines or curves. Such linear analytic elements have been developed also for other partial differential equations, e.g., the modified Helmholz equation and the heat equation, and were constructed by integrating elementary solutions, the point sink and the point doublet, along a line. This approach is limiting for two reasons. First, the existence is required of the elementary solutions, and, second, the integration tends to limit the range of solutions that can be obtained. We present a procedure for generating analytic elements that requires merely the existence of a harmonic function with the desired properties; such functions exist in abundance. The procedure to be presented is used to generalize this harmonic function in such a way that the resulting expression satisfies the applicable differential equation. The approach will be applied, along with numerical examples, for the modified Helmholz equation and for the heat equation, while it is noted that the method is in no way restricted to these equations. The procedure is carried out entirely in terms of complex variables, using Wirtinger calculus.

  7. Base flow separation: A comparison of analytical and mass balance methods

    Science.gov (United States)

    Lott, Darline A.; Stewart, Mark T.

    2016-04-01

    Base flow is the ground water contribution to stream flow. Many activities, such as water resource management, calibrating hydrological and climate models, and studies of basin hydrology, require good estimates of base flow. The base flow component of stream flow is usually determined by separating a stream hydrograph into two components, base flow and runoff. Analytical methods, mathematical functions or algorithms used to calculate base flow directly from discharge, are the most widely used base flow separation methods and are often used without calibration to basin or gage-specific parameters other than basin area. In this study, six analytical methods are compared to a mass balance method, the conductivity mass-balance (CMB) method. The base flow index (BFI) values for 35 stream gages are obtained from each of the seven methods with each gage having at least two consecutive years of specific conductance data and 30 years of continuous discharge data. BFI is cumulative base flow divided by cumulative total discharge over the period of record of analysis. The BFI value is dimensionless, and always varies from 0 to 1. Areas of basins used in this study range from 27 km2 to 68,117 km2. BFI was first determined for the uncalibrated analytical methods. The parameters of each analytical method were then calibrated to produce BFI values as close to the CMB derived BFI values as possible. One of the methods, the power function (aQb + cQ) method, is inherently calibrated and was not recalibrated. The uncalibrated analytical methods have an average correlation coefficient of 0.43 when compared to CMB-derived values, and an average correlation coefficient of 0.93 when calibrated with the CMB method. Once calibrated, the analytical methods can closely reproduce the base flow values of a mass balance method. Therefore, it is recommended that analytical methods be calibrated against tracer or mass balance methods.

  8. Analytical performance of an ultrasonic particle focusing flow cytometer.

    Science.gov (United States)

    Goddard, Gregory R; Sanders, Claire K; Martin, John C; Kaduchak, Gregory; Graves, Steven W

    2007-11-15

    Creation of inexpensive small-flow cytometers is important for applications ranging from disease diagnosis in resource-poor areas to use in distributed sensor networks. In conventional-flow cytometers, hydrodynamics focus particles to the center of a flow stream for analysis, which requires sheath fluid that increases consumable use and waste while dramatically reducing instrument portability. Here we have evaluated, using quantitative measurements of fluorescent microspheres and cells, the performance of a flow cytometer that uses acoustic energy to focus particles to the center of a flow stream. This evaluation demonstrated measurement precision for fluorescence and side scatter CVs for alignment microspheres of 2.54% and 7.7%, respectively. Particles bearing 7 x 10(3) fluorophores were well resolved in a background of 50 nM free fluorophore. The lower limit of detection was determined to be about 650 fluorescein molecules. Analysis of Chinese hamster cells on the system demonstrated that acoustic focusing had no effect on cellular viability. These results indicate that the ultrasonic flow cytometer has the necessary performance for most flow cytometry applications. Furthermore, through robust engineering approaches and the combination of acoustic focusing with low-cost light sources, detectors, and data acquisition systems, it will be possible to achieve a low-cost, truly portable flow cytometer.

  9. Analytic Solution for Magnetohydrodynamic Stagnation Point Flow towards a Stretching Sheet

    Institute of Scientific and Technical Information of China (English)

    DING Qi; ZHANG Hong-Qing

    2009-01-01

    A steady two-dimensional magnetohydrodynamic stagnation point flow towards a stretching sheet with variable surface temperature is investigated. The analytic solution is obtained by homotopy analysis method. Theconvergence region is computed and the feature of the solution is discussed.

  10. Analytic decomposition and numerical procedure for solving the singular boundary value problem arising in viscous flows

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    An efficient analytical decomposition technique was presented for solving the singular nonlinear boundary value problem arising in viscous flow when the Crocco variable was introduced. The approximate analytical solution may be represented in terms of a rapid convergent power series with elegantly computable terms. The reliability and efficiency of the approximate solutions were verified by numerical ones in the literature. The approximate analytical solutions can be successfully applied to give the values of skin friction coefficient.

  11. Analytical solutions for the flow of Carreau and Cross fluids in circular pipes and thin slits

    OpenAIRE

    Sochi, Taha

    2015-01-01

    In this paper, analytical expressions correlating the volumetric flow rate to the pressure drop are derived for the flow of Carreau and Cross fluids through straight rigid circular uniform pipes and long thin slits. The derivation is based on the application of Weissenberg-Rabinowitsch-Mooney-Schofield method to obtain flow solutions for generalized Newtonian fluids through pipes and our adaptation of this method to the flow through slits. The derived expressions are validated by comparing th...

  12. Approximate analytic solutions of stagnation point flow in a porous medium

    Science.gov (United States)

    Kumaran, V.; Tamizharasi, R.; Vajravelu, K.

    2009-06-01

    An efficient and new implicit perturbation technique is used to obtain approximate analytical series solution of Brinkmann equation governing the two-dimensional stagnation point flow in a porous medium. Analytical approximate solution of the classical two-dimensional stagnation point flow is obtained as a limiting case. Also, it is shown that the obtained higher order series solutions agree well with the computed numerical solutions.

  13. Explicit Analytical Solutions of Coupled Fluid Flow Transfer Equation in Heterogeneous Porous Media

    Institute of Scientific and Technical Information of China (English)

    张娜; 蔡睿贤

    2002-01-01

    Explicit analytical solutions are presented for the coupled fluid flow transfer equation in heterogeneous porous media. These analytical solutions are useful for their description of actual flow fields and as benchmark solutions to check the rapidly developing numerical calculations and to study various computational methods such as the discrete approximations of the governing equations and grid generation methods. In addition, some novel mathematical methods are used in the analyses.

  14. Analytically computed rates of seepage flow into drains and cavities

    Science.gov (United States)

    Fujii, N.; Kacimov, A. R.

    1998-04-01

    The known formulae of Freeze and Cherry, Polubarinova-Kochina, Vedernikov for flow rate during 2-D seepage into horizontal drains and axisymmetric flow into cavities are examined and generalized. The case of an empty drain under ponded soil surface is studied and existence of drain depth providing minimal seepage rate is presented. The depth is found exhibiting maximal difference in rate between a filled and an empty drain. 3-D flow to an empty semi-spherical cavity on an impervious bottom is analysed and the difference in rate as compared with a completely filled cavity is established. Rate values for slot drains in a two-layer aquifer are inverted using the Schulgasser theorem from the Polubarinova-Kochina expressions for corresponding flow rates under a dam. Flow to a point sink modelling a semi-circular drain in a layered aquifer is treated by the Fourier transform method. For unsaturated flow the catchment area of a single drain is established in terms of the quasi-linear model assuming the isobaric boundary condition along the drain contour. Optimal shape design problems for irrigation cavities are addressed in the class of arbitrary contours with seepage rate as a criterion and cavity cross-sectional area as an isoperimetric restriction.

  15. Analytical and experimental characterization of a miniature calorimetric sensor in pulsatile flow

    CERN Document Server

    Gelderblom, H; Haartsen, J R; Rutten, M C M; van de Ven, A A F; van de Vosse, F N; 10.1017/S0022112010004234

    2011-01-01

    The behaviour of a miniature calorimetric sensor, which is under consideration for catheter-based coronary artery flow assessment, is investigated in both steady and pulsatile tube flow. The sensor is composed of a heating element operated at constant power, and two thermopiles that measure flow-induced temperature differences over the sensor surface. An analytical sensor model is developed, which includes axial heat conduction in the fluid and a simple representation of the solid wall, assuming a quasi-steady sensor response to the pulsatile flow. To reduce the mathematical problem, described by a two-dimensional advection-diffusion equation, a spectral method is applied. A Fourier transform is then used to solve the resulting set of ordinary differential equations and an analytical expression for the fluid temperature is found. To validate the analytical model, experiments with the sensor mounted in a tube have been performed in steady and pulsatile water flow with various amplitudes and Strouhal numbers. E...

  16. CFD model of an aerating hydrofoil

    Science.gov (United States)

    Scott, D.; Sabourin, M.; Beaulieu, S.; Papillon, B.; Ellis, C.

    2014-03-01

    Improving water quality in the tailrace below hydroelectric dams has become a priority in many river systems. In warm climates, water drawn by the turbine from deep in a reservoir can be deficient in dissolved oxygen (DO), a critical element in maintaining a healthy aquatic ecosystem. Many different solutions have been proposed in order to increase the DO levels in turbine discharge, including: turbine aeration systems (adding air to the water through either the turbine hub, the periphery or through distributed aeration in the runner blades); bubble diffusers in the reservoir or in the tailrace; aerating weirs downstream of the dams; and surface water pumps in the reservoir near the dam. There is a significant potential to increase the effectiveness of these solutions by improving the way that oxygen is introduced into the water; better distributions of bubbles will result in better oxygen transfer. In the present study, a two-phase Computational Fluid Dynamics model has been formulated using a commercial code to study the distribution of air downstream of a simple aerating hydrofoil. The two-phase model uses the Eulerian-Eulerian approach. Appropriate relations are used to model the interphase forces, including the Grace drag force model, the Favre averaged drag force and the Sato enhanced eddy viscosity. The model is validated using experimental results obtained in the water tunnel at the University of Minnesota's Saint Anthony Falls Laboratory. Results are obtained for water velocities between 5 and 10 m/s, air flow rates between 0.5 and 1.5 sL/min and for angles of attack between 0° and -8°. The results of this study show that the CFD model provides a good qualitative comparison to the experimental results by well predicting the wake location at the different flow rates and angles of attack used.

  17. Plasma flow structures as analytical solution of a magneto-hydro-dynamic model with pressure

    Science.gov (United States)

    Paccagnella, R.

    2012-03-01

    In this work starting from a set of magnetohydrodynamic (MHD) equations that describe the dynamical evolution for the pressure driven resistive/interchange modes in a magnetic confinement system, global solutions for the plasma flow relevant for toroidal pinches like tokamaks and reversed field pinches (RFPs) are derived. Analytical solutions for the flow stream function associated with the dominant modes are presented.

  18. On the Analytical Solution of Non-Orthogonal Stagnation Point Flow towards a Stretching Sheet

    DEFF Research Database (Denmark)

    Kimiaeifar, Amin; Bagheri, G. H.; Barari, Amin

    2011-01-01

    An analytical solution for non-orthogonal stagnation point for the steady flow of a viscous and incompressible fluid is presented. The governing nonlinear partial differential equations for the flow field are reduced to ordinary differential equations by using similarity transformations existed i...

  19. High-Performance data flows using analytical models and measurements

    Energy Technology Data Exchange (ETDEWEB)

    Rao, Nageswara S [ORNL; Towlsey, D. [University of Massachusetts; Vardoyan, G. [University of Massachusetts; Kettimuthu, R. [Argonne National Laboratory (ANL); Foster, I. [Argonne National Laboratory (ANL); Settlemyer, Bradley [Los Alamos National Laboratory (LANL)

    2016-01-01

    The combination of analytical models and measurements provide practical configurations and parameters to achieve high data transport rates: (a) buffer sizes and number of parallel streams for improved memory and file transfer rates, (b) Hamilton and Scalable TCP congestion control modules for memory transfers in place of default CUBIC, and (c) direct IO mode for Lustre file systems for wide-area transfers. Conventional parameter selection using full sweeps is impractical in many cases since it takes months. By exploiting the unimodality of throughput profiles, we developed the d-w method that significantly reduces the number of measurements needed for parameter identification. This heuristic method was effective in practice in reducing the measurements by about 90% for Lustre and XFS file transfers.

  20. Analytical skin friction and heat transfer formula for compressible internal flows

    Science.gov (United States)

    Dechant, Lawrence J.; Tattar, Marc J.

    1994-01-01

    An analytic, closed-form friction formula for turbulent, internal, compressible, fully developed flow was derived by extending the incompressible law-of-the-wall relation to compressible cases. The model is capable of analyzing heat transfer as a function of constant surface temperatures and surface roughness as well as analyzing adiabatic conditions. The formula reduces to Prandtl's law of friction for adiabatic, smooth, axisymmetric flow. In addition, the formula reduces to the Colebrook equation for incompressible, adiabatic, axisymmetric flow with various roughnesses. Comparisons with available experiments show that the model averages roughly 12.5 percent error for adiabatic flow and 18.5 percent error for flow involving heat transfer.

  1. INVESTIGATION ON THE SPLASH LENGTH OF THE AERATED JET

    Institute of Scientific and Technical Information of China (English)

    Liu Shi-he; Qu Bo

    2003-01-01

    Atomized flow forms as an aerated jet from high dams impacts against the downstream water surface at high speed. Of all the regions of atomized flow the splash region is in the center of storm rainfall, which might cause certain damage to the hydropower stations and thence more attention should be paid. In this paper the impact of the water drop at the outer edge of the aerated jet against the downstream water surface was analyzed, and the motion of the splash water drop was investigated. Furthermore, a new formula for the calculation of the splash length was suggested, which is in good agreement with the data of model tests and prototype observation.

  2. Hepatocyte-based flow analytical bioreactor for xenobiotics metabolism bioprediction

    Directory of Open Access Journals (Sweden)

    M Helvenstein

    2017-04-01

    Full Text Available The research for new in vitro screening tools for predictive metabolic profiling of drug candidates is of major interest in the pharmaceutical field. The main motivation is to avoid late rejection in drug development and to deliver safer drugs to the market. Thanks to the superparamagnetic properties of iron oxide nanoparticles, a flow bioreactor has been developed which is able to perform xenobiotic metabolism studies. The selected cell line (HepaRG maintained its metabolic competencies once iron oxide nanoparticles were internalized. Based on magnetically trapped cells in a homemade immobilization chamber, through which a flow of circulating phase was injected to transport nutrients and/or the studied xenobiotic, off-line and online (when coupled to a high-performance liquid chromatography chain metabolic assays were developed using diclofenac as a reference compound. The diclofenac demonstrated a similar metabolization profile chromatogram, both with the newly developed setup and with the control situation. Highly versatile, this pioneering and innovative instrumental design paves the way for a new approach in predictive metabolism studies.

  3. Wind-powered dugout aeration

    Energy Technology Data Exchange (ETDEWEB)

    Buchanan, B. [Alberta Agriculture, Barrhead, AB (Canada); Chang, J. [Engineering Services, Edmonton, AB (Canada)

    1993-12-31

    A review is presented of past and present use of wind power on Alberta farms, concentrating on the merits of wind-powered aeration systems for improving water quality in farm dugouts. Dugout water quality is seriously affected by nutrient-rich sediments causing excessive algae and plant growth. If dissolved oxygen is not maintained anaerobic decomposition begins, resulting in black, smelly water. Aeration assures an adequate level of dissolved oxygen to control taste and odor and maintains good water quality. There are two common means of aerating dugouts from windmills: use of a floating mechanical type aerator, and a bank-mounted windmill and diaphragm-type pump. Bank-mounted windmill aerators were studied as they were considered to have the most potential for aerating dugouts. Windmill monitoring was carried out on a farm near Manning, Alberta using a Koenders windmill (12 blade rotor). Tests showed that the windmill maintained the dissolved oxygen levels near saturation, and averaged ca 1.0 cubic feet of air pumped per minute. Operating pressure was 5 psi, windmill starting speed was 12 km/h wind, and stopping speed was 8 km/h winds. Tests were also carried out on a Breeze-1 windmill, a 3 blade airplane propeller type windmill. The system average 3.3 cubic feet of air per minute, and started at very low wind speeds of 5-8 km/h. 2 figs.

  4. Experimental Analysis of Pressure Fluctuations behind a Bottom Aerator

    Institute of Scientific and Technical Information of China (English)

    1999-01-01

    Experimental observations show that the random process of two-phase flow beh ind an aerator is an ergodic process and its amplitude distribution is similar t o a normal distribution. The maximum pressure fluctuation is at the re-attachme n t point where the jet-trajectory flow over the aerator re-attaches to bottom o f the channel, and its amplitude is 2-3 times larger than when there is no aerato r. There is a dominant frequency of 1.24 Hz in the model, but the coherence in th e frequency domain is not obvious for other frequencies beside the dominant frequ ency. There is a large vortex at the re-attachment point behind the aerator but correlation among the measurement points is not obvious in the time domain.

  5. Five-point Element Scheme of Finite Analytic Method for Unsteady Groundwater Flow

    Institute of Scientific and Technical Information of China (English)

    Xiang Bo; Mi Xiao; Ji Changming; Luo Qingsong

    2007-01-01

    In order to improve the finite analytic method's adaptability for irregular unit, by using coordinates rotation technique this paper establishes a five-point element scheme of finite analytic method. It not only solves unsteady groundwater flow equation but also gives the boundary condition. This method can be used to calculate the three typical questions of groundwater. By compared with predecessor's computed result, the result of this method is more satisfactory.

  6. Finite analytic numerical solution of heat transfer and flow past a square channel cavity

    Science.gov (United States)

    Chen, C.-J.; Obasih, K.

    1982-01-01

    A numerical solution of flow and heat transfer characteristics is obtained by the finite analytic method for a two dimensional laminar channel flow over a two-dimensional square cavity. The finite analytic method utilizes the local analytic solution in a small element of the problem region to form the algebraic equation relating an interior nodal value with its surrounding nodal values. Stable and rapidly converged solutions were obtained for Reynolds numbers ranging to 1000 and Prandtl number to 10. Streamfunction, vorticity and temperature profiles are solved. Local and mean Nusselt number are given. It is found that the separation streamlines between the cavity and channel flow are concave into the cavity at low Reynolds number and convex at high Reynolds number (Re greater than 100) and for square cavity the mean Nusselt number may be approximately correlated with Peclet number as Nu(m) = 0.365 Pe exp 0.2.

  7. Two dimensional analytical solution for a partially vegetated compound channel flow

    Institute of Scientific and Technical Information of China (English)

    HUAI Wen-xin; XU Zhi-gang; YANG Zhong-hua; ZENG Yu-hong

    2008-01-01

    The theory of an eddy viscosity model is applied to the study of the flow in a compound channel which is partially vegetated. The governing equation is constituted by analyzing the longitudinal forces acting on the unit volume where the effect of the vegetation on the flow is considered as a drag force item. The compound channel is di- vided into 3 sub-regions in the transverse direction, and the coefficients in every region's differential equations were solved simultaneously. Thus, the analytical solution of the transverse distribution of the depth-averaged velocity for uniform flow in a partially vege- tated compound channel was obtained. The results can be used to predict the transverse distribution of bed shear stress, which has an important effect on the transportation of sediment. By comparing the analytical results with the measured data, the analytical so- lution in this paper is shown to be sufficiently accurate to predict most hydraulic features for engineering design purposes.

  8. Treatment Wetland Aeration without Electricity? Lessons Learned from the First Experiment Using a Wind-Driven Air Pump

    Directory of Open Access Journals (Sweden)

    Johannes Boog

    2016-11-01

    Full Text Available Aerated treatment wetlands have become an increasingly recognized technology for treating wastewaters from domestic and various industrial origins. To date, treatment wetland aeration is provided by air pumps which require access to the energy grid. The requirement for electricity increases the ecological footprint of an aerated wetland and limits the application of this technology to areas with centralized electrical infrastructure. Wind power offers another possibility as a driver for wetland aeration, but its use for this purpose has not yet been investigated. This paper reports the first experimental trial using a simple wind-driven air pump to replace the conventional electric air blowers of an aerated horizontal subsurface flow wetland. The wind-driven air pump was connected to a two-year old horizontal flow aerated wetland which had been in continuous (24 h aeration since startup. The wind-driven aeration system functioned, however it was not specifically adapted to wetland aeration. As a result, treatment performance decreased compared to prior continuous aeration. Inconsistent wind speed at the site may have resulted in insufficient pressure within the aeration manifold, resulting in insufficient air supply to the wetland. This paper discusses the lessons learned during the experiment.

  9. Analytical solutions for squeeze flow with partial wall slip

    DEFF Research Database (Denmark)

    Laun, HM; Rady, M; Hassager, Ole

    1999-01-01

    Squeeze flow between parallel plates of a purely viscous material is considered for small gaps both for a Newtonian and power law fluid with partial wall slip. The results for the squeeze force as a function of the squeezing speed reduce to the Stefan and Scott equations in the no slip limit......, respectively. The slip velocity at the plate increases linearly with the radius up to the rim slip velocity upsilon(s). For small Saps H, the resulting apparent Newtonian rim shear rate-measured for a constant rim shear stress, i.e. an imposed force increasing proportional to 1/H-yields a straight line...... if plotted versus 1/H. The slope of the straight line is equal to 6 upsilon(s) whereas the intersect with the ordinate yields the effective Newtonian rim shear rate to be converted into the true rim shear rate by means of the power law exponent. The advantage of the new technique is the separation of bulk...

  10. Numerical simulation of landfill aeration using computational fluid dynamics.

    Science.gov (United States)

    Fytanidis, Dimitrios K; Voudrias, Evangelos A

    2014-04-01

    The present study is an application of Computational Fluid Dynamics (CFD) to the numerical simulation of landfill aeration systems. Specifically, the CFD algorithms provided by the commercial solver ANSYS Fluent 14.0, combined with an in-house source code developed to modify the main solver, were used. The unsaturated multiphase flow of air and liquid phases and the biochemical processes for aerobic biodegradation of the organic fraction of municipal solid waste were simulated taking into consideration their temporal and spatial evolution, as well as complex effects, such as oxygen mass transfer across phases, unsaturated flow effects (capillary suction and unsaturated hydraulic conductivity), temperature variations due to biochemical processes and environmental correction factors for the applied kinetics (Monod and 1st order kinetics). The developed model results were compared with literature experimental data. Also, pilot scale simulations and sensitivity analysis were implemented. Moreover, simulation results of a hypothetical single aeration well were shown, while its zone of influence was estimated using both the pressure and oxygen distribution. Finally, a case study was simulated for a hypothetical landfill aeration system. Both a static (steadily positive or negative relative pressure with time) and a hybrid (following a square wave pattern of positive and negative values of relative pressure with time) scenarios for the aeration wells were examined. The results showed that the present model is capable of simulating landfill aeration and the obtained results were in good agreement with corresponding previous experimental and numerical investigations.

  11. Simple analytic functions for modeling three-dimensional flow in layered aquifers

    Science.gov (United States)

    Fitts, Charles R.

    1989-05-01

    Analytic functions are presented for modeling three-dimensional steady groundwater flow in stratified aquifers. The functions create discontinuity in the potential across an infinite plane while maintaining continuity of the potential gradient across the plane. These functions may be superimposed with other analytic functions to model three-dimensional flow in stratified aquifers under a variety of boundary conditions. An interface between two layers of different hydraulic conductivity, an impermeable boundary, or a thin leaky layer may be modeled using such functions. These functions are simple compared to functions for doublet distributions over finite plane panels and are suitable for efficient modeling.

  12. Some analytical solutions for flows of Casson fluid with slip boundary conditions

    Directory of Open Access Journals (Sweden)

    K. Ramesh

    2015-09-01

    Full Text Available In the present paper, we have studied three fundamental flows namely Couette, Poiseuille and generalized Couette flows of an incompressible Casson fluid between parallel plates using slip boundary conditions. The equations governing the flow of Casson fluid are non-linear in nature. Analytical solutions of the non-linear governing equations with non-linear boundary conditions are obtained for each case. The effect of the various parameters on the velocity and volume flow rate for each problem is studied and the results are presented through graphs. It is observed that, the presence of Casson number decreases the velocity and volume flow rate of the fluid. Increasing of slip parameter increases the velocity and volume flow rate in both Poiseuille and generalized Couette flows.

  13. Landfill aeration in the framework of a reclamation project in Northern Italy.

    Science.gov (United States)

    Raga, Roberto; Cossu, Raffaello

    2014-03-01

    In situ aeration by means of the Airflow technology was proposed for landfill conditioning before landfill mining in the framework of a reclamation project in Northern Italy. A 1-year aeration project was carried out on part of the landfill with the objective of evaluating the effectiveness of the Airflow technology for landfill aerobization, the evolution of waste biological stability during aeration and the effects on leachate and biogas quality and emissions. The main outcomes of the 1-year aeration project are presented in the paper. The beneficial effect of the aeration on waste biological stability was clear (63% reduction of the respiration index); however, the effectiveness of aeration on the lower part of the landfill is questionable, due to the limited potential for air migration into the leachate saturated layers. During the 1-year in situ aeration project approx. 275 MgC were discharged from the landfill body with the extracted gas, corresponding to 4.6 gC/kgDM. However, due to the presence of anaerobic niches in the aerated landfill, approx. 46% of this amount was extracted as CH4, which is higher than reported in other aeration projects. The O2 conversion quota was lower than reported in other similar projects, mainly due to the higher air flow rates applied. The results obtained enabled valuable recommendations to be made for the subsequent application of the Airflow technology to the whole landfill.

  14. A Simple Analytical Model of Coupled Single Flow Channel over Porous Electrode in Vanadium Redox Flow Battery with Serpentine Flow Channel

    CERN Document Server

    Ke, Xinyou; Prahl, Joseph M; Savinell, Robert F

    2016-01-01

    A simple analytical model of a layered system comprised of a single passage of a serpentine flow channel and a parallel underlying porous electrode (or porous layer) is proposed. This analytical model is derived from Navier-Stokes motion in the flow channel and Darcy-Brinkman model in the porous layer. The continuities of flow velocity and normal stress are applied at the interface between the flow channel and the porous layer. The effects of the inlet volumetric flow rate, thickness of the flow channel and thickness of a typical carbon fiber paper porous layer on the volumetric flow rate within this porous layer are studied. The maximum current density based on the electrolyte volumetric flow rate is predicted, and found to be consistent with reported numerical simulation. It is found that, for a mean inlet flow velocity of 33.3 cm s-1, the analytical maximum current density is estimated to be 377 mA cm-2, which compares favorably with experimental result reported by others of ~400 mA cm-2.

  15. A simple analytical model of coupled single flow channel over porous electrode in vanadium redox flow battery with serpentine flow channel

    Science.gov (United States)

    Ke, Xinyou; Alexander, J. Iwan D.; Prahl, Joseph M.; Savinell, Robert F.

    2015-08-01

    A simple analytical model of a layered system comprised of a single passage of a serpentine flow channel and a parallel underlying porous electrode (or porous layer) is proposed. This analytical model is derived from Navier-Stokes motion in the flow channel and Darcy-Brinkman model in the porous layer. The continuities of flow velocity and normal stress are applied at the interface between the flow channel and the porous layer. The effects of the inlet volumetric flow rate, thickness of the flow channel and thickness of a typical carbon fiber paper porous layer on the volumetric flow rate within this porous layer are studied. The maximum current density based on the electrolyte volumetric flow rate is predicted, and found to be consistent with reported numerical simulation. It is found that, for a mean inlet flow velocity of 33.3 cm s-1, the analytical maximum current density is estimated to be 377 mA cm-2, which compares favorably with experimental result reported by others of ∼400 mA cm-2.

  16. Analytical network model on the flow and thermal characteristics of cyclic flow cryogenic regenerators

    Science.gov (United States)

    Hua, Xiao Jia; Zhong, Guo Fang

    1988-11-01

    The flow and thermal characteristics of rapid cyclic flow cryogenic regenerators and their interrelationship have been analysed using the linear network theory and perturbation method. The effect of flow resistance, gas storage in void volume, temperature distribution, interaction of pressure wave and cyclic mass flow, and the factor of real gas were considered. A computer simulation program, CFCRX, was developed and the numerical results obtained are presented. This theory provides a better understanding of the working mechanism of cryogenic regenerators.

  17. Comparative Research to Surface Aeration and Blasting Aeration System Based on LCC Theory

    Science.gov (United States)

    Liai, CHEN; Hongxun, HOU; Weibiao, FEI; Eryan, ZHAO

    2017-05-01

    It is difficult to select the suitable aeration system for the designers of wastewater treatment plant (WWTP). In this paper, taking two WWTPs with surface aeration systems and blasting aeration respectively for an example, LCC theory was adapted to analysis the cost of consumption and the environmental impact, which caused by the different aeration system. Research results showed that: (1) In the 20-year life cycle, the LCC mainly depended on the cost of energy consumption whatever blasting aeration system or surface aeration, while the LCC of blasting aeration system affected by the equipment maintenance cost, maintenance cost, economic losses caused by wastewater loss and environmental load in maintenance period. (2) The LCC of blasting aeration system was lower than the surface aeration in general, on the premise of the standard discharge; (3) the blasting aeration system estimated a saving of 60,0000RMB annually in costs compared with the surface aeration.

  18. Analytical solution of electrohydrodynamic flow and transport in rectangular channels: inclusion of double layer effects

    KAUST Repository

    Joekar-Niasar, V.

    2013-01-25

    Upscaling electroosmosis in porous media is a challenge due to the complexity and scale-dependent nonlinearities of this coupled phenomenon. "Pore-network modeling" for upscaling electroosmosis from pore scale to Darcy scale can be considered as a promising approach. However, this method requires analytical solutions for flow and transport at pore scale. This study concentrates on the development of analytical solutions of flow and transport in a single rectangular channel under combined effects of electrohydrodynamic forces. These relations will be used in future works for pore-network modeling. The analytical solutions are valid for all regimes of overlapping electrical double layers and have the potential to be extended to nonlinear Boltzmann distribution. The innovative aspects of this study are (a) contribution of overlapping of electrical double layers to the Stokes flow as well as Nernst-Planck transport has been carefully included in the analytical solutions. (b) All important transport mechanisms including advection, diffusion, and electromigration have been included in the analytical solutions. (c) Fully algebraic relations developed in this study can be easily employed to upscale electroosmosis to Darcy scale using pore-network modeling. © 2013 Springer Science+Business Media Dordrecht.

  19. Analytical solution of laminar-laminar stratified two-phase flows with curved interfaces

    Energy Technology Data Exchange (ETDEWEB)

    Brauner, N.; Rovinsky, J.; Maron, D.M. [Tel-Aviv Univ. (Israel)

    1995-09-01

    The present study represents a complete analytical solution for laminar two-phase flows with curved interfaces. The solution of the Navier-Stokes equations for the two-phases in bipolar coordinates provides the `flow monograms` describe the relation between the interface curvature and the insitu flow geometry when given the phases flow rates and viscosity ratios. Energy considerations are employed to construct the `interface monograms`, whereby the characteristic interfacial curvature is determined in terms of the phases insitu holdup, pipe diameter, surface tension, fluids/wall adhesion and gravitation. The two monograms are then combined to construct the system `operational monogram`. The `operational monogram` enables the determination of the interface configuration, the local flow characteristics, such as velocity profiles, wall and interfacial shear stresses distribution as well as the integral characteristics of the two-phase flow: phases insitu holdup and pressure drop.

  20. Application of the homotopy method for analytical solution of non-Newtonian channel flows

    Energy Technology Data Exchange (ETDEWEB)

    Roohi, Ehsan [Department of Aerospace Engineering, Sharif University of Technology, PO Box 11365-8639, Azadi Avenue, Tehran (Iran, Islamic Republic of); Kharazmi, Shahab [Department of Mechanical Engineering, Sharif University of Technology, PO Box 11365-8639, Azadi Avenue, Tehran (Iran, Islamic Republic of); Farjami, Yaghoub [Department of Computer Engineering, University of Qom, Qom (Iran, Islamic Republic of)], E-mail: roohi@sharif.edu

    2009-06-15

    This paper presents the homotopy series solution of the Navier-Stokes and energy equations for non-Newtonian flows. Three different problems, Couette flow, Poiseuille flow and Couette-Poiseuille flow have been investigated. For all three cases, the nonlinear momentum and energy equations have been solved using the homotopy method and analytical approximations for the velocity and the temperature distribution have been obtained. The current results agree well with those obtained by the homotopy perturbation method derived by Siddiqui et al (2008 Chaos Solitons Fractals 36 182-92). In addition to providing analytical solutions, this paper draws attention to interesting physical phenomena observed in non-Newtonian channel flows. For example, it is observed that the velocity profile of non-Newtonian Couette flow is indistinctive from the velocity profile of the Newtonian one. Additionally, we observe flow separation in non-Newtonian Couette-Poiseuille flow even though the pressure gradient is negative (favorable). We provide physical reasoning for these unique phenomena.

  1. Analytical solutions to a hillslope-storage kinematic wave equation for subsurface flow

    NARCIS (Netherlands)

    Troch, P.A.; Loon, van E.; Hilberts, A.

    2002-01-01

    Hillslope response has traditionally been studied by means of the hydraulic groundwater theory. Subsurface flow from a one-dimensional hillslope with a sloping aquifer can be described by the Boussinesq equation [Mem. Acad. Sci. Inst. Fr. 23 (1) (1877) 252–260]. Analytical solutions to Boussinesq's

  2. Analytical and Numerical Solutions of Vapor Flow in a Flat Plate Heat Pipe

    Directory of Open Access Journals (Sweden)

    Mohsen GOODARZI

    2012-03-01

    Full Text Available In this paper, the optimal homotopy analysis method (OHAM and differential transform method (DTM were applied to solve the problem of 2D vapor flow in flat plate heat pipes. The governing partial differential equations for this problem were reduced to a non-linear ordinary differential equation, and then non-dimensional velocity profiles and axial pressure distributions along the entire length of the heat pipe were obtained using homotopy analysis, differential transform, and numerical fourth-order Runge-Kutta methods. The reliability of the two analytical methods was examined by comparing the analytical results with numerical ones. A brief discussion about the advantages of the two applied analytical methods relative to each other is presented. Furthermore, the effects of the Reynolds number and the ratio of condenser to evaporator lengths on the flow variables were discussed.Graphical abstract

  3. Fault detection and isolation of sensors in aeration control systems.

    Science.gov (United States)

    Carlsson, Bengt; Zambrano, Jesús

    2016-01-01

    In this paper, we consider the problem of fault detection (FD) and isolation in the aeration system of an activated sludge process. For this study, the dissolved oxygen in each aerated zone is assumed to be controlled automatically. As the basis for an FD method we use the ratio of air flow rates into different zones. The method is evaluated in two scenarios: using the Benchmark Simulation Model no. 1 (BSM1) by Monte Carlo simulations and using data from a wastewater treatment plant. The FD method shows good results for a correct and early FD and isolation.

  4. AERATION EFFECT OF SUBMERGED JET ON HYDRAULIC CHARACTERISTICS

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    A water-air two-phase turbulence mathematical model was proposed, The mass-weighted average was adoptedfor velocity, air mass fraction and turbulent parameters. Thealgebraic stress equation was used to calculate the Reynoldsstress. The pulsating flux of air mass fraction was simulatedby employing the concept of the eddy viscosity. The numericalsimulation of aerated flow in plunge pool shows that, for the same depth, aeration may decrease the time-averaged pressureon pool floor and increase slightly the turbulent intensity. Thecomputed concentration and pressure distributions coincidewith the experimental data.

  5. Gradually-varied flow profiles in open channels analytical solutions by using Gaussian hypergeometric function

    CERN Document Server

    Jan, Chyan-Deng

    2014-01-01

    Gradually-varied flow (GVF) is a steady non-uniform flow in an open channel with gradual changes in its water surface elevation. The evaluation of GVF profiles under a specific flow discharge is very important in hydraulic engineering. This book proposes a novel approach to analytically solve the GVF profiles by using the direct integration and Gaussian hypergeometric function. Both normal-depth- and critical-depth-based dimensionless GVF profiles are presented. The novel approach has laid the foundation to compute at one sweep the GVF profiles in a series of sustaining and adverse channels, w

  6. Analytical description of stationary ideal MHD flows with constant total pressure

    CERN Document Server

    Golovin, Sergey V

    2009-01-01

    Incompressible stationary flows of ideal plasma are observed. By introduction of curvilinear system of coordinates in which streamlines and magnetic force lines form a family of coordinate surfaces, MHD equations are partially integrated and brought to a certain convenient form. It is demonstrated that the admissible group of Bogoyavlenskij's symmetry transformations performs as a scaling transformation for the curvilinear coordinates. Analytic description of stationary flows with constant total pressure is given. It is shown, that contact magnetic surfaces of such flows are translational surfaces, i.e. are swept out by translating one curve rigidly along another curve. Explicit examples of solutions with constant total pressure possessing a significant functional arbitrariness are given.

  7. Analytical Solutions of Time Periodic Electroosmotic Flow in a Semicircular Microchannel

    Directory of Open Access Journals (Sweden)

    Shaowei Wang

    2015-01-01

    Full Text Available The time periodic electroosmotic flow of Newtonian fluids through a semicircular microchannel is studied under the Debye–Hückel approximation. Analytical series of solutions are found, and they consist of a time-dependent oscillating part and a time-dependent generating or transient part. Some new physical phenomena are found. The electroosmotic flow driven by an alternating electric field is not periodic in time, but quasi-periodic. There is a phase shift between voltage and flow, which is only dependent on the frequency of external electric field.

  8. Characterization and Prediction of the Volume Flow Rate Aerating a Cross Ventilated Bilding by Means of Experimental Techniques and Numerical Approaches

    DEFF Research Database (Denmark)

    Larsen, Tine Steen; Nikolopoulos, N.; Nikolopoulos, A.

    2011-01-01

    anemometers across the openings, whilst the numerical methodology is based on the time-dependant solution of the governing Navier-Stokes equations. The experimental data are compared to the corresponding numerical results, revealing the unsteady character of the flow field especially at large incidence angles......The paper presents an extensive experimental and numerical study on a cross-ventilated building providing important features of the induced flow patterns at the two openings as a function of the free stream wind velocity’s magnitude and its incidence angle. The experimental data are measured via....... Furthermore, additional information regarding the flow field near the opening edges, not easily extracted by experimental methods, provide an in depth sight in the main characteristics of the flow field both at the openings but also inside the building. Finally, a new methodology for the approximation...

  9. Experimental investigations of aeration efficiency in high-head gated circular conduits.

    Science.gov (United States)

    Cihat Tuna, M; Ozkan, Fahri; Baylar, Ahmet

    2014-01-01

    The primary purpose of water aeration is to increase the oxygen saturation of the water. This can be achieved by using hydraulic structures because of substantial air bubble entrainment at these structures. Closed conduit aeration is a particular instance of this. While there has been a great deal of research on air-demand ratio within closed conduit, very little research has specifically addressed aeration efficiency of closed conduit. In the present work an experimental study was conducted to investigate the aeration efficiency of high-head gated circular conduits. Results showed that high-head gated circular conduits were effective for oxygen transfer. The effects of Froude number and ratio of the water cross-sectional flow area to the conduit cross-sectional area on aeration efficiency were particularly significant, whereas the effect of conduit length was only moderate. Further, a design formula for the aeration efficiency was presented relating the aeration efficiency to ratio of water cross-sectional flow area to conduit cross-sectional area and Froude number. The obtained results will be useful in future modeling processes and aid the practicing engineer in predicting aeration efficiency for design purposes.

  10. An analytical solution for transient radial flow through unsaturated fractured porous media

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Yu-Shu; Pan, Lehua

    2004-02-13

    This paper presents analytical solutions for one-dimensional radial transient flow through horizontal, unsaturated fractured rock formation. In these solutions, unsaturated flow through fractured media is described by a linearized Richards' equation, while fracture-matrix interaction is handled using the dual-continuum concept. Although linearizing Richards' equation requires a specially correlated relationship between relative permeability and capillary pressure functions for both fractures and matrix, these specially formed relative permeability and capillary pressure functions are still physically meaningful. These analytical solutions can thus be used to describe the transient behavior of unsaturated flow in fractured media under the described model conditions. They can also be useful in verifying numerical simulation results, which, as demonstrated in this paper, are otherwise difficult to validate.

  11. Analytical solution of conjugate turbulent forced convection boundary layer flow over plates

    Directory of Open Access Journals (Sweden)

    Joneydi Shariatzadeh Omid

    2016-01-01

    Full Text Available A conjugate (coupled forced convection heat transfer from a heated conducting plate under turbulent boundary layer flow is considered. A heated plate of finite thickness is cooled under turbulent forced convection boundary layer flow. Because the conduction and convection boundary layer flow is coupled (conjugated in the problem, a semi-analytical solution based on Differential Transform Method (DTM is presented for solving the non-linear integro-differential equation occurring in the problem. The main conclusion is that in the conjugate heat transfer case the temperature distribution of the plate is flatter than the one in the non-conjugate case. This feature is more pronounced under turbulent flow when compared with the laminar flow.

  12. NUMERICAL SIMULATION OF 3-D AERATED JET BEHIND FLIP BUCKET OF OVERFLOW DAM

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    Aerated jet,such as the jet flow behind the flip bucket of an overflow dam, widely exists in hydraulic engineering. Up to now the model test and prototype observation have been two main methods of studying the aerated jet for a special hydraulic project. In this paper, a three-dimensional mathematical model for the aerated jet was established. It seems that the suggested model has high predictive power by comparison with the results of model tests and prototype observations, which is very useful in the study of energy dissipation and jet flow atomization.

  13. A Hybrid Analytical-Numerical Solution to the Laminar Flow inside Biconical Ducts

    Directory of Open Access Journals (Sweden)

    Thiago Antonini Alves

    2015-10-01

    Full Text Available In this work was presented a hybrid analytical-numerical solution to hydrodynamic problem of fully developed Newtonian laminar flow inside biconical ducts employing the Generalized Integral Transform Technique (GITT. In order to facilitate the analytical treatment and the application of the boundary conditions, a Conformal Transform was used to change the domain into a more suitable coordinate system. Thereafter, the GITT was applied on the momentum equation to obtain the velocity field. Numerical results were obtained for quantities of practical interest, such as maximum and minimum velocity, Fanning friction factor, Poiseuille number, Hagenbach factor and hydrodynamic entry length.

  14. Vibration response of a pipe subjected to two-phase flow: Analytical formulations and experiments

    Energy Technology Data Exchange (ETDEWEB)

    Ortiz-Vidal, L. Enrique, E-mail: leortiz@sc.usp.br [Department of Mechanical Engineering, Sao Carlos School of Engineering, University of Sao Paulo (USP), Av., Trabalhador São-carlense, 400, 13566-970 São Carlos, SP (Brazil); Mureithi, Njuki W., E-mail: njuki.mureithi@polymtl.ca [Department of Mechanical Engineering, Polytechnique Montreal, Département de Géniemécanique 2900, H3T 1J7 Montreal, QC (Canada); Rodriguez, Oscar M.H., E-mail: oscarmhr@sc.usp.br [Department of Mechanical Engineering, Sao Carlos School of Engineering, University of Sao Paulo (USP), Av., Trabalhador São-carlense, 400, 13566-970 São Carlos, SP (Brazil)

    2017-03-15

    Highlights: • Analytical formulations for two-phase flow-induced vibration (2-FIV) are presented. • Standard deviation of acceleration pipe response is a function of the square of shear velocity. • Peak frequency is correlated to hydrodynamic mass and consequently to void fraction. • Dynamic pipe response increases with increasing mixture velocity and void fraction. • Hydrodynamic mass in 2-FIV in horizontal pipe is proportional to mixture density. - Abstract: This paper treats the two-phase flow-induced vibration in pipes. A broad range of two-phase flow conditions, including bubbly, dispersed and slug flow, were tested in a clamped-clamped straight horizontal pipe. The vibration response of both transversal directions for two span lengths was measured. From experimental results, an in-depth discussion on the nature of the flow excitation and flow-parameters influence is presented. The hydrodynamic mass parameter is also studied. Experimental results suggest that it is proportional to mixture density. On the other hand, two analytical formulations were developed and tested against experimental results. One formulation predicts the quadratic trend between standard deviation of acceleration and shear velocity found in experiments. The other formulation indicates that the peak-frequency of vibration response depends strongly on void fraction. It provides accurate predictions of peak-frequency, predicting 97.6% of the data within ±10% error bands.

  15. Hydrodynamics of Highly Viscous Flow past a Compound Particle: Analytical Solution

    Directory of Open Access Journals (Sweden)

    Longhua Zhao

    2016-11-01

    Full Text Available To investigate the translation of a compound particle in a highly viscous, incompressible fluid, we carry out an analytic study on flow past a fixed spherical compound particle. The spherical object is considered to have a rigid kernel covered with a fluid coating. The fluid within the coating has a different viscosity from that of the surrounding fluid and is immiscible with the surrounding fluid. The inertia effect is negligible for flows both inside the coating and outside the object. Thus, flows are in the Stokes regime. Taking advantage of the symmetry properties, we reduce the problem in two dimensions and derive the explicit formulae of the stream function in the polar coordinates. The no-slip boundary condition for the rigid kernel and the no interfacial mass transfer and force equilibrium conditions at fluid interfaces are considered. Two extreme cases: the uniform flow past a sphere and the uniform flow past a fluid drop, are reviewed. Then, for the fluid coating the spherical object, we derive the stream functions and investigate the flow field by the contour plots of stream functions. Contours of stream functions show circulation within the fluid coating. Additionally, we compare the drag and the terminal velocity of the object with a rigid sphere or a fluid droplet. Moreover, the extended results regarding the analytical solution for a compound particle with a rigid kernel and multiple layers of fluid coating are reported.

  16. Explicit analytical wave solutions of unsteady 1D ideal gas flow with friction and heat transfer

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    Several families of algebraically explicit analytical wavesolutions are derived for the unsteady 1D ideal gas flow with friction and heat-transfer, which include one family of travelling wave solutions, three families of standing wave solutions and one standing wave solution. \\{Among\\} them, the former four solution families contain arbitrary functions, so actually there are infinite analytical wave solutions having been derived. Besides their very important theoretical meaning, such analytical wave solutions can guide the development of some new equipment, and can be the benchmark solutions to promote the development of computational fluid dynamics. For example, we can use them to check the accuracy, convergence and effectiveness of various numerical computational methods and to improve the numerical computation skills such as differential schemes, grid generation ways and so on.

  17. Analytical and grid-free solutions to the Lighthill-Whitham-Richards traffic flow model

    KAUST Repository

    Mazaré, Pierre Emmanuel

    2011-12-01

    In this article, we propose a computational method for solving the Lighthill-Whitham-Richards (LWR) partial differential equation (PDE) semi-analytically for arbitrary piecewise-constant initial and boundary conditions, and for arbitrary concave fundamental diagrams. With these assumptions, we show that the solution to the LWR PDE at any location and time can be computed exactly and semi-analytically for a very low computational cost using the cumulative number of vehicles formulation of the problem. We implement the proposed computational method on a representative traffic flow scenario to illustrate the exactness of the analytical solution. We also show that the proposed scheme can handle more complex scenarios including traffic lights or moving bottlenecks. The computational cost of the method is very favorable, and is compared with existing algorithms. A toolbox implementation available for public download is briefly described, and posted at http://traffic.berkeley.edu/project/downloads/lwrsolver. © 2011 Elsevier Ltd.

  18. AN ANALYTICAL SOLUTION OF KINEMATIC WAVE EQUATIONS FOR OVERLAND FLOW UNDER GREEN-AMPT INFILTRATION

    Directory of Open Access Journals (Sweden)

    Giorgio Baiamonte

    2010-03-01

    Full Text Available This paper deals with the analytical solution of kinematic wave equations for overland flow occurring in an infiltrating hillslope. The infiltration process is described by the Green-Ampt model. The solution is derived only for the case of an intermediate flow regime between laminar and turbulent ones. A transitional regime can be considered a reliable flow condition when, to the laminar overland flow, is also associated the effect of the additional resistance due to raindrop impact. With reference to the simple case of an impervious hillslope, a comparison was carried out between the present solution and the non-linear storage model. Some applications of the present solution were performed to investigate the effect of main parameter variability on the hillslope response. Particularly, the effect of hillslope geometry and rainfall intensity on the time to equilibrium is shown.

  19. Analytic Flow Equations for the Fermi Liquid Parameters of the Anderson Impurity Model.

    Science.gov (United States)

    Pandis, Vassilis; Hewson, Alex C

    2015-08-14

    The low temperature behavior of a Fermi liquid can be described in terms of quasiparticle excitations that are in 1-1 correspondence with those of the noninteracting system. Because of adiabatic continuity, the Landau parameters, which describe the interactions between the quasiparticles, must evolve continuously as the interactions are turned on and be described by a set of flow equations. For strongly correlated electron systems it is not possible to follow this flow in perturbation theory when the interactions become strong. We explore the idea here of overcoming this problem by renormalizing the quasiparticles in this flow using a renormalized perturbation theory. This approach is tested in the case of a single impurity Anderson model. Analytic flow equations are derived which give excellent results for the Landau parameters in the strong correlation regime.

  20. Analytical solutions for the flow of Carreau and Cross fluids in circular pipes and thin slits

    CERN Document Server

    Sochi, Taha

    2015-01-01

    In this paper, analytical expressions correlating the volumetric flow rate to the pressure drop are derived for the flow of Carreau and Cross fluids through straight rigid circular uniform pipes and long thin slits. The derivation is based on the application of Weissenberg-Rabinowitsch-Mooney-Schofield method to obtain flow solutions for generalized Newtonian fluids through pipes and our adaptation of this method to the flow through slits. The derived expressions are validated by comparing their solutions to the solutions obtained from direct numerical integration. They are also validated by comparison to the solutions obtained from the variational method which we proposed previously. In all the investigated cases, the three methods agree very well. The agreement with the variational method also lends more support to this method and to the variational principle which the method is based upon.

  1. Evaluation of re-aeration equations for river Ghataprabha, Karnataka, India and development of refined equation.

    Science.gov (United States)

    Kalburgi, P B; Jha, R; Ojha, C S P; Deshannavar, U B

    2015-01-01

    Stream re-aeration is an extremely important component to enhance the self-purification capacity of streams. To estimate the dissolved oxygen (DO) present in the river, estimation of re-aeration coefficient is mandatory. Normally, the re-aeration coefficient is expressed as a function of several stream variables, such as mean stream velocity, shear stress velocity, bed slope, flow depth and Froude number. Many empirical equations have been developed in the last years. In this work, 13 most popular empirical re-aeration equations, used for re-aeration prediction, have been tested for their applicability in Ghataprabha River system, Karnataka, India, at various locations. Extensive field data were collected during the period March 2008 to February 2009 from seven different sites located in the river to observe re-aeration coefficient using mass balance approach. The performance of re-aeration equations have been evaluated using various error estimations, namely, the standard error (SE), mean multiplicative error (MME), normalized mean error (NME) and correlation statistics. The results show that the predictive equation developed by Jha et al. (Refinement of predictive re-aeration equations for a typical Indian river. Hydrological Process. 2001;15(6):1047-1060), for a typical Indian river, yielded the best agreement with the values of SE, MME, NME and correlation coefficient r. Furthermore, a refined predictive equation has been developed for river Ghataprabha using least-squares algorithm that minimizes the error estimates.

  2. Comparison of analytic models of instability of rarefied gas flow in a channel

    Energy Technology Data Exchange (ETDEWEB)

    Aksenova, Olga A. [St.-Petersburg State University, Department of Mathematics and Mechanics, 198504, Universitetskiy pr., 28, Peterhof, St.-Petersburg (Russian Federation); Khalidov, Iskander A. [St.-Petersburg State Polytechnic University, Department of Mathematics and Mechanics, 195251, Polytechnicheskaya ul., 29, St.-Petersburg (Russian Federation)

    2014-12-09

    Numerical and analytical results are compared concerning the limit properties of the trajectories, attractors and bifurcations of rarefied gas flows in channels. The cascade of bifurcations obtained in our previous analytical and numerical investigations is simulated numerically for different scattering functions V generalizing the ray-diffuse reflection of gas particles from the surface. The main purpose of numerical simulation by Monte Carlo method is the investigation of the properties of different analytic nonlinear dynamic systems corresponding to rarefied gas flow in a channel. The results are compared as well for the models suggested originally by R. N. Miroshin, as for the approximations considered for the first time or for studied in our subsequent papers. Analytical solutions we obtained earlier for the ray reflection which means only one determined velocity of scattered from the walls gas atoms, generally different from the specular reflection. The nonlinear iterative equation describing a rarefied gas flow in a long channel becomes unstable in some regions of corresponding parameters of V (it means the sensitivity to boundary conditions). The values of the parameters are found from analytical approximations in these regions. Numerical results show that the chaotic behavior of the nonlinear dynamic system corresponds to strange attractors and distinguishes clearly from Maxwellian distribution and from the equilibrium on the whole. In the regions of instability (as the dimension of the attractor increases) the search for a corresponding state requires a lot more computation time and a lot of data (the amount of data required increases exponentially with embedding dimension). Therefore the main complication in the computation is reducing as well the computing time as the amount of data to find a suitably close solution. To reduce the computing time our analytical results are applied. Flow conditions satisfying the requirements to the experiment are

  3. Algebraically explicit analytical solutions for the unsteady non-Newtonian swirling flow in an annular pipe

    Institute of Scientific and Technical Information of China (English)

    CAI; Ruixian; GOU; Chenhua

    2006-01-01

    This paper presents two algebraically explicit analytical solutions for the incompressible unsteady rotational flow of Oldroyd-B type in an annular pipe. The first solution is derived with the common method of separation of variables. The second one is deduced with the method of separation of variables with addition developed in recent years. The first analytical solution is of clear physical meaning and both of them are fairly simple and valuable for the newly developing computational fluid dynamics. They can be used as the benchmark solutions to verify the applicability of the existing numerical computational methods and to inspire new differencing schemes, grid generation ways, etc. Moreover, a steady solution for the generalized second grade rheologic fluid flow is also presented. The correctness of these solutions can be easily proven by substituting them into the original governing equation.

  4. Approximate analytical solution of MHD flow of an Oldroyd 8-constant fluid in a porous medium

    Directory of Open Access Journals (Sweden)

    Faisal Salah

    2014-12-01

    Full Text Available The steady flow in an incompressible, magnetohydrodynamic (MHD Oldroyd 8-constant fluid in a porous medium with the motion of an infinite plate is investigated. Using modified Darcy’s law of an Oldroyd 8-constant fluid, the equations governing the flow are modelled. The resulting nonlinear boundary value problem is solved using the homotopy analysis method (HAM. The obtained approximate analytical solutions clearly satisfy the governing nonlinear equations and all the imposed initial and boundary conditions. The convergence of the HAM solutions for different orders of approximation is demonstrated. For the Newtonian case, the approximate analytical solution via HAM is shown to be in close agreement with the exact solution. Finally, the variations of velocity field with respect to the magnetic field, porosity and non-Newtonian fluid parameters are graphically shown and discussed.

  5. Simple analytical model of capillary flow in an evaporating sessile drop.

    Science.gov (United States)

    Tarasevich, Yuri Yu

    2005-02-01

    An analytical expression of hydrodynamic potential inside an evaporating sessile drop with pinned contact line is found. The problem is considered for a hemispherical drop (with the contact angle of 90 degrees ) at the very early stages of the evaporation process when the shape of the drop is still a hemisphere and the evaporation field is uniform. The capillary flow carries a fluid from the drop apex to the contact line. Comparison with the published calculations performed using lubrication approximation (very thin drop) suggests that qualitative picture of the capillary flow is insensitive to the ratio of initial drop height to the drop radius.

  6. Fin characteristics of aerator devices with lateral deflectors

    Institute of Scientific and Technical Information of China (English)

    WU Jian-hua; LI Dan; MA Fei; QIAN Shang-tuo

    2013-01-01

    The fins will be formed if the lateral deflectors in the side-walls with a bottom aerator device are improperly designed,and the flow regime downstream of the aerator device will be worsened.In this paper,the height and the length of the fins induced by the lateral deflectors are theoretically analyzed along with their influencing factors,and the fin characteristics are experimentally investigated on the basis of the theoretical analysis.It is shown that the intensities of the fins are strongly dependent on the ratio of the lateral cavity length to the bottom cavity length,and other factors,like the working head,the height and the angle of the lateral deflector,the flow Froude number around the aerator device,affect the fins indirectly through the changes of the lateral cavity length.When an aerator device with lateral deflectors is designed,it is crucial to match the above mentioned ratio,and to make the ratio of the two cavity lengths less than 1.0 in order to avoid the generation of the fins.

  7. Analytic models of heterogenous magnetic fields for liquid metal flow simulations

    OpenAIRE

    Votyakov, E. V.; Kassinos, S. C.; Albets-Chico, X.

    2009-01-01

    A physically consistent approach is considered for defining an external magnetic field as needed in computational fluid dynamics problems involving magnetohydrodynamics (MHD). The approach results in simple analytical formulae that can be used in numerical studies where an inhomogeneous magnetic field influences a liquid metal flow. The resulting magnetic field is divergence and curl-free, and contains two components and parameters to vary. As an illustration, the following examples are consi...

  8. Analytic Approximations for the Flows and Heat Transfer in Microchannels between Two Parallel Plates

    Directory of Open Access Journals (Sweden)

    A. El-Nahhas

    2012-01-01

    (CHF. The homotopy analysis method is applied via a polynomial exponential basis to obtain analytic approximations for this problem. A rarefaction effects on the velocity profile and the flow friction are investigated. Also, as a result of the application, the effects, on the Nusselt number Nu, with variation in Brinkman number Br and Knudsen number Kn for both (CWT case and (CHF case are discussed.

  9. Exact analytical solutions for the Poiseuille and Couette-Poiseuille flow of third grade fluid between parallel plates

    Science.gov (United States)

    Danish, Mohammad; Kumar, Shashi; Kumar, Surendra

    2012-03-01

    Exact analytical solutions for the velocity profiles and flow rates have been obtained in explicit forms for the Poiseuille and Couette-Poiseuille flow of a third grade fluid between two parallel plates. These exact solutions match well with their numerical counter parts and are better than the recently developed approximate analytical solutions. Besides, effects of various parameters on the velocity profile and flow rate have been studied.

  10. Analytical description of stationary ideal MHD flows with constant total pressure

    Energy Technology Data Exchange (ETDEWEB)

    Golovin, Sergey V., E-mail: sergey@hydro.nsc.r [Lavrentyev Institute of Hydrodynamics SB RAS, 630090 Novosibirsk (Russian Federation); Department of Mechanics and Mathematics, Novosibirsk State University, 630090 Novosibirsk (Russian Federation)

    2010-02-01

    Incompressible stationary flows of ideal plasma are studied. By introduction of curvilinear system of coordinates in which streamlines and magnetic force lines form a family of coordinate surfaces, MHD equations are partially integrated and brought to a certain convenient form. It is demonstrated that the admissible group of Bogoyavlenskij's symmetry transformations (Bogoyavlenskij, 2001 ) performs as a scaling transformation (the scaling factor is an arbitrary function of one variable) for the curvilinear coordinates. Analytic description of stationary flows with constant total pressure is given. It is shown, that contact magnetic surfaces of such flows are translational surfaces, i.e. are swept out by translating one curve rigidly along another curve. Examples of solutions with constant total pressure possessing an arbitrariness in one function of two variables and three functions of one variable are given.

  11. An analytic solution for barotropic flow along a variable slope topography

    Science.gov (United States)

    Kuehl, Joseph J.

    2014-11-01

    An analytic solution is derived for the generic oceanographic situation of a barotropic current flowing along sloping topography. It is shown that the shallow water equations can be reduced to a heat-like equation in which βeffect is balanced by Ekman dissipation. For constant topography, the system is found to admit a well-known similarity solution and this solution is generalized to the case of variable topography. Several properties of the solution are explored, and an example is given for flow along the northern Gulf of Mexico slope, between the De Soto Canyon and the Mississippi Canyon. This "Topographic β-plume" solution may serve as a model for further research concerning the influence exerted by geophysical boundary layers on the interior flow via their structure and stability.

  12. Analytical and numerical study of the electro-osmotic annular flow of viscoelastic fluids.

    Science.gov (United States)

    Ferrás, L L; Afonso, A M; Alves, M A; Nóbrega, J M; Pinho, F T

    2014-04-15

    In this work we present semi-analytical solutions for the electro-osmotic annular flow of viscoelastic fluids modeled by the Linear and Exponential PTT models. The viscoelastic fluid flows in the axial direction between two concentric cylinders under the combined influences of electrokinetic and pressure forcings. The analysis invokes the Debye-Hückel approximation and includes the limit case of pure electro-osmotic flow. The solution is valid for both no slip and slip velocity at the walls and the chosen slip boundary condition is the linear Navier slip velocity model. The combined effects of fluid rheology, electro-osmotic and pressure gradient forcings on the fluid velocity distribution are also discussed.

  13. Investigation of wall bounded flows using SPH and the unified semi-analytical wall boundary conditions

    CERN Document Server

    Mayrhofer, Arno; Violeau, Damien; Ferrand, Martin

    2013-01-01

    The semi-analytical wall boundary conditions present a mathematically rigorous framework to prescribe the influence of solid walls in SPH for fluid flows. In this paper they are investigated with respect to the skew-adjoint property which implies exact energy conservation. It will be shown that this property holds only in the limit of the continuous SPH approximation, whereas in the discrete SPH formulation it is only approximately true, leading to numerical noise. This noise, interpreted as form of "turbulence", is treated using an additional volume diffusion term in the continuity equation which we show is equivalent to an approximate Riemann solver. Subsequently two extensions to the boundary conditions are presented. The first dealing with a variable driving force when imposing a volume flux in a periodic flow and the second showing a generalization of the wall boundary condition to Robin type and arbitrary-order interpolation. Two modifications for free-surface flows are presented for the volume diffusio...

  14. Analytical models for flow control in subsonic and supersonic diffusing flow paths using steady blowing and suction

    Science.gov (United States)

    Sarimurat, Mehmet Nasir

    Flow blowing/suction has multiple beneficial effects on the performance of axial flow compressors. In both low speed and high speed compressors a small amount of flow blowing and/or suction can be applied in the region of adverse pressure gradient to control the boundary layer separation and obtain high pressure ratio across the compressor. On the other hand in high speed compressors where a passage shock is present inside the passage, flow blowing/suction can also be used to manage the shock location inside the passage and increase the operating range of the compressor. In the first part of this study, an analytical model based on the integral method for boundary layer with flow blowing in incompressible flows is developed that shows the effect of mass, momentum, velocity magnitude and injection angle of the blowing flow on the behavior of the boundary layer. According to the model the change in the boundary layer momentum thickness across the blowing location is linear function of the momentum of the blowing flow and exponential function of the velocity of the blowing flow. Also if the size of the blowing slot and the velocity of the blown flow are kept constant, when the amount of the blown flow is increased by increasing the blowing angle, there is an "optimum" angle that maximizes the decrease in the momentum thickness across the blowing station. This angle is a function of the velocity ratio and it reaches an asymptotic value of around 40°. The model also shows that the change in the trailing-edge momentum thickness is an exponential function of the change in the momentum thickness across the blowing location. The developed modeled is confirmed for the NACA-65-410 low speed cascade using Computational Fluid Dynamics and a good agreement between the theory and CFD is obtained. In the second part of the thesis a quasi-1D inviscid and compressible flow theory in a converging/diverging flow passage is presented that can predict the amount of flow blowing or

  15. Influence of aeration of Candida albicans during culturing on their surface aggregation in the presence of adhering Streptococcus gordonii

    NARCIS (Netherlands)

    Millsap, KW; van der Mei, HC; Busscher, HJ; Bos, R.R.M.

    1999-01-01

    Candida albicans surfaces are extremely sensitive to changes in growth conditions. In this study, adhesion to glass of aerated and non-aerated C. albicans ATCC 10261 in the presence and absence of adhering Streptococcus gordonii NCTC 7869 was determined in a parallel plate flow chamber. In addition,

  16. A Novel Analytical Approach to Pulsatile Blood Flow in the Arterial Network.

    Science.gov (United States)

    Flores, Joaquín; Alastruey, Jordi; Corvera Poiré, Eugenia

    2016-10-01

    Haemodynamic simulations using one-dimensional (1-D) computational models exhibit many of the features of the systemic circulation under normal and diseased conditions. We propose a novel linear 1-D dynamical theory of blood flow in networks of flexible vessels that is based on a generalized Darcy's model and for which a full analytical solution exists in frequency domain. We assess the accuracy of this formulation in a series of benchmark test cases for which computational 1-D and 3-D solutions are available. Accordingly, we calculate blood flow and pressure waves, and velocity profiles in the human common carotid artery, upper thoracic aorta, aortic bifurcation, and a 20-artery model of the aorta and its larger branches. Our analytical solution is in good agreement with the available solutions and reproduces the main features of pulse waveforms in networks of large arteries under normal physiological conditions. Our model reduces computational time and provides a new approach for studying arterial pulse wave mechanics; e.g.,  the analyticity of our model allows for a direct identification of the role played by physical properties of the cardiovascular system on the pressure waves.

  17. Towards advanced aeration modelling: from blower to bubbles to bulk.

    Science.gov (United States)

    Amaral, Andreia; Schraa, Oliver; Rieger, Leiv; Gillot, Sylvie; Fayolle, Yannick; Bellandi, Giacomo; Amerlinck, Youri; Mortier, Séverine T F C; Gori, Riccardo; Neves, Ramiro; Nopens, Ingmar

    2017-02-01

    Aeration is an essential component of aerobic biological wastewater treatment and is the largest energy consumer at most water resource recovery facilities. Most modelling studies neglect the inherent complexity of the aeration systems used. Typically, the blowers, air piping, and diffusers are not modelled in detail, completely mixed reactors in a series are used to represent plug-flow reactors, and empirical correlations are used to describe the impact of operating conditions on bubble formation and transport, and oxygen transfer from the bubbles to the bulk liquid. However, the mechanisms involved are very complex in nature and require significant research efforts. This contribution highlights why and where there is a need for more detail in the different aspects of the aeration system and compiles recent efforts to develop physical models of the entire aeration system (blower, valves, air piping and diffusers), as well as adding rigour to the oxygen transfer efficiency modelling (impact of viscosity, bubble size distribution, shear and hydrodynamics). As a result of these model extensions, more realistic predictions of dissolved oxygen profiles and energy consumption have been achieved. Finally, the current needs for further model development are highlighted.

  18. Analytical Solution of Flow and Heat Transfer over a Permeable Stretching Wall in a Porous Medium

    Directory of Open Access Journals (Sweden)

    M. Dayyan

    2013-01-01

    Full Text Available Boundary layer flow through a porous medium over a stretching porous wall has seen solved with analytical solution. It has been considered two wall boundary conditions which are power-law distribution of either wall temperature or heat flux. These are general enough to cover the isothermal and isoflux cases. In addition to momentum, both first and second laws of thermodynamics analyses of the problem are investigated. The governing equations are transformed into a system of ordinary differential equations. The transformed ordinary equations are solved analytically using homotopy analysis method. A comprehensive parametric study is presented, and it is shown that the rate of heat transfer increases with Reynolds number, Prandtl number, and suction to the surface.

  19. Compressible flow in front of an axisymmetric blunt object: analytic approximation and astrophysical implications

    CERN Document Server

    Keshet, Uri

    2016-01-01

    Compressible flows around blunt objects have diverse applications, but current analytic treatments are inaccurate and limited to narrow parameter regimes. We show that the gas-dynamic flow in front of an axisymmetric blunt body is accurately derived analytically using a low order expansion of the perpendicular gradients in terms of the parallel velocity. This reproduces both subsonic and supersonic flows measured and simulated for a sphere, including the transonic regime and the bow shock properties. Some astrophysical implications are outlined, in particular for planets in the solar wind and for clumps and bubbles in the intergalactic medium. The bow shock standoff distance normalized by the obstacle curvature is $\\sim 2/(3g)$ in the strong shock limit, where $g$ is the compression ratio. For a subsonic Mach number $M$ approaching unity, the thickness $\\delta$ of an initially weak, draped magnetic layer is a few times larger than in the incompressible limit, with amplification $\\sim ({1+1.3M^{2.6}})/({3\\delt...

  20. TOWARD MORE REALISTIC ANALYTIC MODELS OF THE HELIOTAIL: INCORPORATING MAGNETIC FLATTENING VIA DISTORTION FLOWS

    Energy Technology Data Exchange (ETDEWEB)

    Kleimann, Jens; Fichtner, Horst [Ruhr-Universität Bochum, Fakultät für Physik und Astronomie, Institut für Theoretische Physik IV, Bochum (Germany); Röken, Christian [Universität Regensburg, Fakultät für Mathematik, Regensburg (Germany); Heerikhuisen, Jacob, E-mail: jk@tp4.rub.de, E-mail: hf@tp4.rub.de, E-mail: christian.roeken@mathematik.uni-regensburg.de, E-mail: jacob.heerikhuisen@uah.edu [Department of Space Science and Center for Space Plasma and Aeronomic Research, University of Alabama in Huntsville, Huntsville, AL 35899 (United States)

    2016-01-01

    Both physical arguments and simulations of the global heliosphere indicate that the tailward heliopause is flattened considerably in the direction perpendicular to both the incoming flow and the large-scale interstellar magnetic field. Despite this fact, all of the existing global analytical models of the outer heliosheath's magnetic field assume a circular cross section of the heliotail. To eliminate this inconsistency, we introduce a mathematical procedure by which any analytically or numerically given magnetic field can be deformed in such a way that the cross sections along the heliotail axis attain freely prescribed, spatially dependent values for their total area and aspect ratio. The distorting transformation of this method honors both the solenoidality condition and the stationary induction equation with respect to an accompanying flow field, provided that both constraints were already satisfied for the original magnetic and flow fields prior to the transformation. In order to obtain realistic values for the above parameters, we present the first quantitative analysis of the heliotail's overall distortion as seen in state-of-the-art three-dimensional hybrid MHD–kinetic simulations.

  1. Autotrophic Nitrogen Removal in a Membrane-Aerated Biofilm Reactor Under Continuous Aeration: A Demonstration

    DEFF Research Database (Denmark)

    Gilmore, Kevin R.; Terada, Akihiko; Smets, Barth F.

    2013-01-01

    This work describes the successful coupling of partial nitrification (nitritation) and anaerobic ammonium oxidation in a membrane-aerated biofilm reactor (MABR) with continuous aeration. Controlling the relative surface loadings of oxygen versus ammonium prevented complete nitrite oxidation and a...

  2. An analytical solution for transient flow of Bingham viscoplastic materials in rock fractures

    Science.gov (United States)

    Amadei, B.; Savage, W.Z.

    2001-01-01

    We present below an analytical solution to model the one-dimensional transient flow of a Bingham viscoplastic material in a fracture with parallel walls (smooth or rough) that is subjected to an applied pressure gradient. The solution models the acceleration and the deceleration of the material as the pressure gradient changes with time. Two cases are considered: A pressure gradient applied over a finite time interval and an applied pressure gradient that is constant over time. The solution is expressed in dimensionless form and can therefore be used for a wide range of Bingham viscoplastic materials. The solution is also capable of capturing the transition that takes place in a fracture between viscoplastic flow and rigid plug flow. Also, it shows the development of a rigid central layer in fractures, the extent of which depends on the fluid properties (viscosity and yield stress), the magnitude of the pressure gradient, and the fracture aperture and surface roughness. Finally, it is shown that when a pressure gradient is applied and kept constant, the solution for the fracture flow rate converges over time to a steady-state solution that can be defined as a modified cubic law. In this case, the fracture transmissivity is found to be a non-linear function of the head gradient. This solution provides a tool for a better understanding of the flow of Bingham materials in rock fractures, interfaces, and cracks. ?? 2001 Elsevier Science Ltd. All rights reserved.

  3. Analytical Solutions of a Space-Time Fractional Derivative of Groundwater Flow Equation

    Directory of Open Access Journals (Sweden)

    Abdon Atangana

    2014-01-01

    Full Text Available The classical Darcy law is generalized by regarding the water flow as a function of a noninteger order derivative of the piezometric head. This generalized law and the law of conservation of mass are then used to derive a new equation for groundwater flow. Two methods including Frobenius and Adomian decomposition method are used to obtain an asymptotic analytical solution to the generalized groundwater flow equation. The solution obtained via Frobenius method is valid in the vicinity of the borehole. This solution is in perfect agreement with the data observed from the pumping test performed by the institute for groundwater study on one of their boreholes settled on the test site of the University of the Free State. The test consisted of the pumping of the borehole at the constant discharge rate Q and monitoring the piezometric head for 350 minutes. Numerical solutions obtained via Adomian method are compared with the Barker generalized radial flow model for which a fractal dimension for the flow is assumed. Proposition for uncertainties in groundwater studies was given.

  4. Semi-analytical model of cross-borehole flow experiments for fractured medium characterization

    Science.gov (United States)

    Roubinet, D.; Irving, J.; Day-Lewis, F. D.

    2014-12-01

    The study of fractured rocks is extremely important in a wide variety of research fields where the fractures and faults can represent either rapid access to some resource of interest or potential pathways for the migration of contaminants in the subsurface. Identification of their presence and determination of their properties are critical and challenging tasks that have led to numerous fracture characterization methods. Among these methods, cross-borehole flowmeter analysis aims to evaluate fracture connections and hydraulic properties from vertical-flow-velocity measurements conducted in one or more observation boreholes under forced hydraulic conditions. Previous studies have demonstrated that analysis of these data can provide important information on fracture connectivity, transmissivity, and storativity. Estimating these properties requires the development of analytical and/or numerical modeling tools that are well adapted to the complexity of the problem. Quantitative analysis of cross-borehole flowmeter experiments, in particular, requires modeling formulations that: (i) can be adapted to a variety of fracture and experimental configurations; (ii) can take into account interactions between the boreholes because their radii of influence may overlap; and (iii) can be readily cast into an inversion framework that allows for not only the estimation of fracture hydraulic properties, but also an assessment of estimation error. To this end, we present a new semi-analytical formulation for cross-borehole flow in fractured media that links transient vertical-flow velocities measured in one or a series of observation wells during hydraulic forcing to the transmissivity and storativity of the fractures intersected by these wells. Our model addresses the above needs and provides a flexible and computationally efficient semi-analytical framework having strong potential for future adaptation to more complex configurations. The proposed modeling approach is demonstrated

  5. Towards dial-a-molecule by integrating continuous flow, analytics and self-optimisation.

    Science.gov (United States)

    Sans, Victor; Cronin, Leroy

    2016-04-21

    The employment of continuous-flow platforms for synthetic chemistry is becoming increasingly popular in research and industrial environments. Integrating analytics in-line enables obtaining a large amount of information in real-time about the reaction progress, catalytic activity and stability, etc. Furthermore, it is possible to influence the reaction progress and selectivity via manual or automated feedback optimisation, thus constituting a dial-a-molecule approach employing digital synthesis. This contribution gives an overview of the most significant contributions in the field to date.

  6. On-Line Characterization of Aerosols Formed in a Jet Flow Condenser for Analytical Applications

    Energy Technology Data Exchange (ETDEWEB)

    Ludwig, Chr.; Mohr, M. [EMPA Duebendorf (Switzerland)

    2004-03-01

    With a jet flow condenser (JFC) aerosol particles can be generated from gases containing high boiling substances. This can be used for transferring these substances from the hot carrier gas into an analytical device. In this study we have investigated the particle number size distribution (NSD) produced in two JFCs with different geometry. Experiments were performed with elemental zinc as a model substance. Zinc has been volatilised in a tubular furnace and the particles generated in the JFC were characterized on-line by a Scanning Mobility Particle Sizer (SMPS). (author)

  7. Modelling a flows in supply chain with analytical models: Case of a chemical industry

    Science.gov (United States)

    Benhida, Khalid; Azougagh, Yassine; Elfezazi, Said

    2016-02-01

    This study is interested on the modelling of the logistics flows in a supply chain composed on a production sites and a logistics platform. The contribution of this research is to develop an analytical model (integrated linear programming model), based on a case study of a real company operating in the phosphate field, considering a various constraints in this supply chain to resolve the planning problems for a better decision-making. The objectives of this model is to determine and define the optimal quantities of different products to route, to and from the various entities in the supply chain studied.

  8. Analytic Approximate Solutions for Unsteady Two-Dimensional and Axisymmetric Squeezing Flows between Parallel Plates

    Directory of Open Access Journals (Sweden)

    Mohammad Mehdi Rashidi

    2008-01-01

    Full Text Available The flow of a viscous incompressible fluid between two parallel plates due to the normal motion of the plates is investigated. The unsteady Navier-Stokes equations are reduced to a nonlinear fourth-order differential equation by using similarity solutions. Homotopy analysis method (HAM is used to solve this nonlinear equation analytically. The convergence of the obtained series solution is carefully analyzed. The validity of our solutions is verified by the numerical results obtained by fourth-order Runge-Kutta.

  9. Purging dissolved oxygen by nitrogen bubble aeration

    Science.gov (United States)

    Yamashita, Tatsuya; Ando, Keita

    2016-11-01

    We apply aeration with nitrogen microbubbles to water in order to see whether oxygen gas originally dissolved in the water at one atmosphere is purged by the aeration. The concentration of dissolved oxygen (DO) is detected by a commercial DO meter. To detect the dissolved nitrogen (DN) level, we observe the growth of millimetre-sized bubbles nucleated at glass surfaces in contact with the aerated water and compare it with the Epstein-Plesset theory that accounts for DO/DN diffusions and the presence of the glass surfaces. Comparisons between the experiment and the theory suggest that the DO in the water are effectively purged by the aeration.

  10. Composting of tobacco plant waste by manual turning and forced aeration system

    Directory of Open Access Journals (Sweden)

    Nonglak Saithep

    2009-05-01

    Full Text Available The efficiency of tobacco plant waste composting, by the manual turning and the forced aeration system, was compared. Tobacco plant waste, cow manure, urea fertiliser, and a compost inoculum mixture at a 100:10:0.2:0.01 ratio respectively, with 60% (w/v moisture content, were set up in piling forms. The piles of the manual turning system were provided with turning aeration by hand at intervals of 7 days during the composting process. For the forced aeration system, each pile was aerated by a 3-HP air pump with a flow rate of 19 litres min-1 for 15 minutes every morning and evening. The completely randomised design of turned and force-aerated piles was performed in triplicate. The composting activity of both systems during the composting period was measured by several parameters: temperature, pH, moisture content, C/N ratio, growth of microorganisms, cellulase activity, and nicotine degradation in the set-up piles. Both systems had similar temperature, pH, and moisture content conditions in the piles during the composting process. However, the forced aeration system was more advantageous for the growth of mesophilic and thermophilic microorganisms, for cellulase activity from cellulase-producing microorganisms, and for nicotine degradation, when compared to the manual turning system. In conclusion, the forced aeration system was more efficient than the manual turning system in composting and is a viable alternative method for the composting process.

  11. Optimizing aeration rates for minimizing membrane fouling and its effect on sludge characteristics in a moving bed membrane bioreactor

    Energy Technology Data Exchange (ETDEWEB)

    Rahimi, Yousef, E-mail: yrahimi@ut.ac.ir [Department of Civil and Environmental Engineering, Graduate Faculty of Environment, University of Tehran, No. 25 Qods St., Enghelab Ave., Tehran (Iran, Islamic Republic of); Torabian, Ali, E-mail: atorabi@ut.ac.ir [Department of Civil and Environmental Engineering, Graduate Faculty of Environment, University of Tehran, No. 25 Qods St., Enghelab Ave., Tehran (Iran, Islamic Republic of); Mehrdadi, Naser, E-mail: mehrdadi@ut.ac.ir [Department of Civil and Environmental Engineering, Graduate Faculty of Environment, University of Tehran, No. 25 Qods St., Enghelab Ave., Tehran (Iran, Islamic Republic of); Habibi-Rezaie, Mehran, E-mail: mhabibi@khayam.ut.ac.ir [Department of Biotechnology, Faculty of Biology, College of Science, University of Tehran, No. 25 Qods St., Enghelab Ave., Tehran (Iran, Islamic Republic of); Pezeshk, Hamid, E-mail: pezeshk@khayam.ut.ac.ir [Department of Statistics, Faculty of Mathematics and Computer, College of Science, University of Tehran, No. 25 Qods St., Enghelab Ave., Tehran (Iran, Islamic Republic of); Nabi-Bidhendi, Gholam-Reza, E-mail: ghhendi@ut.ac.ir [Department of Civil and Environmental Engineering, Graduate Faculty of Environment, University of Tehran, No. 25 Qods St., Enghelab Ave., Tehran (Iran, Islamic Republic of)

    2011-02-28

    Research highlights: {yields} There is an optimum aeration rate in the MBMBR process compartments. {yields} Optimum aeration rate maximizes nutrients removal. {yields} Optimum aeration rate minimizes membrane fouling. {yields} Both aeration rates in MBBR and membrane compartment can affect on membrane permeability. - Abstract: In MBR processes, sufficient aeration is necessary to maintain sustainable flux and to retard membrane fouling. Membrane permeability, sludge characteristics, nutrient removal and biomass growth at various air flow rates in the membrane and moving bed biofilm reactor (MBBR) compartments were studied in a pilot plant. The highest nitrogen and phosphorous removal rates were found at MBBR aeration rates of 151 and 85 L h{sup -1} and a specific aeration demand per membrane area (SAD{sub m}) of 1.2 and 0.4m{sub air}{sup 3} m{sup -2} h{sup -1}, respectively. A linear correlation was found between the amount of attached biofilm and the nutrient removal rate. The aeration rate in the MBBR compartment and SAD{sub m} significantly influenced the sludge characteristics and membrane permeability. The optimum combination of the aeration rate in the MBBR compartment and SAD{sub m} were 151 L h{sup -1} and 0.8-1.2m{sub air}{sup 3}m{sub membrane}{sup -2} h{sup -1}, respectively.

  12. Experimental And Analytical Study Of Heat Transfer And Fluid Flow Through Aluminum Foams

    Science.gov (United States)

    Mancin, Simone; Zilio, Claudio; Rossetto, Luisa; Cavallini, Alberto

    2010-05-01

    This paper aims at investigating the air heat transfer and fluid flow through eight Aluminum open cell foam samples with different number of pores per linear inch (PPI ranging between 5 and 40), almost constant porosity (around 0.92-0.93) and different foam core heights (20 and 40 mm). The experimental heat transfer coefficient and pressure drop measurements have been collected in a test rig built at Dipartimento di Fisica Tecnica of the University of Padova. Three different heat fluxes have been imposed: 25.0, 32.5 and 40.0 kW m-2 and the air mass flow rate has been varied between 0.005 and 0.025 kg s-1, with air approach velocity between 2 and 5 m s-1. The effect of the foam height on the heat transfer has been experimentally analysed. Finally, the pressure drop measurements have been compared against an analytical model suggested in the open literature.

  13. UNSTEADY BOUNDARY LAYER FLOW ALONG A STRETCHING CYLINDER AN ANALYTICAL SOLUTION

    Directory of Open Access Journals (Sweden)

    M. Y. Akl

    2014-01-01

    Full Text Available The axisymetric laminar boundary layer unsteady flow along a continuously stretching cylinder immersed in a viscous and incompressible fluid is studied. The governing partial boundary layer equations in cylindrical form are first transformed into ordinary differential equations these equations are solved analytically using the optimal modified Homotopy Asymptotic method in order to get a closed form solution for the dimensionless functions f and è. The main object of this study is to investigate the effect of an unsteady motion of a stretching cylinder on the flow and heat transfer characteristics such as surface skin friction and surface heat flux. These characteristics have a direct effect on the quality of the final product of the fiber manufacturing and extrusion processes. Considerable effects were found for the dynamic parameter (γ, the curvature parameter (ρ and the prandtl number (pr on the velocity and the heat transfer.

  14. Navier-Stokes-Fourier analytic solutions for non-isothermal Couette slip gas flow

    Directory of Open Access Journals (Sweden)

    Milićev Snežana S.

    2016-01-01

    Full Text Available The explicit and reliable analytical solutions for steady plane compressible non-isothermal Couette gas flow are presented. These solutions for velocity and temperature are developed by macroscopic approach from Navier-Stokes-Fourier system of continuum equations and the velocity slip and the temperature jump first order boundary conditions. Variability of the viscosity and thermal conductivity with temperature is involved in the model. The known result for the gas flow with constant and equal temperatures of the walls (isothermal walls is verified and a new solution for the case of different temperature of the walls is obtained. Evan though the solution for isothermal walls correspond to the gas flow of the Knudsen number Kn≤0.1, i.e. to the slip and continuum flow, it is shown that the gas velocity and related shear stress are also valid for the whole range of the Knudsen number. The deviation from numerical results for the same system is less than 1%. The reliability of the solution is confirmed by comparing with results of other authors which are obtained numerically by microscopic approach. The advantage of the presented solution compared to previous is in a very simple applicability along with high accuracy. [Projekat Ministarstva nauke Republike Srbije, br. 35046 i 174014

  15. Analytical study of the non orthogonal stagnation point flow of a micro polar fluid

    Directory of Open Access Journals (Sweden)

    M. Ali. Abbas

    2017-01-01

    Full Text Available In this paper we consider the steady two dimensional flow of micro polar fluids on a flat plate. The flow under discussion is the modified Hiemenz flow for a micro polar fluid which occurs in the hjkns + skms boundary layer near an orthogonal stagnation point. The full governing equation reduced to a modified Hiemenz flow. The solution to the boundary value problem is governed by two non dimensional parameters, the material parameter K and the ratio of the micro rotation to skin friction parameter n. The obtained nonlinear coupled ordinary differential equations are solved by using the Homotopy perturbation method. Comparison between numerical and analytical solutions of the problem is shown in tables form for different values of the governing parameters K and n. Effects of the material parameter K on the velocity profile and microrotation profiles for different cases of n are discussed graphically as well as numerically. Velocity profile decreases as the material parameter K increases and the microrotation profile increases as the material parameter K increases for different cases of n.

  16. 两段错向流曝气生物滤池处理生活污水%Two-sect Up and Down Flow Biological Aerated Filter for Domestic Wastewater Treatment

    Institute of Scientific and Technical Information of China (English)

    司马卫平; 董建威

    2011-01-01

    采用半柔性填料和酶促好氧填料的两段错向流曝气生物滤池(TUDBAF)处理生活污水,考察了试验启动阶段水力停留时间对SS、COD和NH3-N的去除效果的影响,并分析了反冲洗对BAFU段生物膜活性的影响.结果表明:在水力停留时间6.5~13.0 h条件下,SS 和COD的去除率随水力停留时间的增加而增大,且其去除率分别达91.6%和83.6%以上;反应器对氨氮的去除主要集中在BAFU段,该段对氨氮的去除占总去除率的70%以上;BAFU段采用气水联合反冲洗过程中可以出水TSS浓度(708mg/L)作为该段反冲洗的终点.%A two-sect up and down flow biological aerated filter (TUDBAF) with semi-soft media and enzyme-enhanced aerobiosis biofilling was used to treat domestic wastewater. Influence of HRT on SS, COD and NH3-N removal efficiency was investigated. Also the influence of backwash on the activity of biofilms was analyzed. Experimental results showed that under HRT of 6.5~13.0h, removal rates of SS and COD both increased with the increasing HRT and that both removal rates of which was above 91.6% and 83.6% respectively. It also indicated that removal of NH3-N mainly concentrated in BAF U and that of NH3-N in BAF U was over 70% of total removal rate. Effluent concentration of TSS of 708mg/L in BAF U using of air and water backwash process can serve as the end of backwash.

  17. Analytical solutions of heat transfer for laminar flow in rectangular channels

    Directory of Open Access Journals (Sweden)

    Rybiński Witold

    2014-12-01

    Full Text Available The paper presents two analytical solutions namely for Fanning friction factor and for Nusselt number of fully developed laminar fluid flow in straight mini channels with rectangular cross-section. This type of channels is common in mini- and microchannel heat exchangers. Analytical formulae, both for velocity and temperature profiles, were obtained in the explicit form of two terms. The first term is an asymptotic solution of laminar flow between parallel plates. The second one is a rapidly convergent series. This series becomes zero as the cross-section aspect ratio goes to infinity. This clear mathematical form is also inherited by the formulae for friction factor and Nusselt number. As the boundary conditions for velocity and temperature profiles no-slip and peripherally constant temperature with axially constant heat flux were assumed (H1 type. The velocity profile is assumed to be independent of the temperature profile. The assumption of constant temperature at the channel’s perimeter is related to the asymptotic case of channel’s wall thermal resistance: infinite in the axial direction and zero in the peripheral one. It represents typical conditions in a minichannel heat exchanger made of metal.

  18. Analytical Model of an Asymmetric Sunspot with a Steady Plasma Flow in its Penumbra

    Science.gov (United States)

    Solov'ev, A. A.; Kirichek, E. A.

    2016-08-01

    A new exact analytical solution to the stationary problem of ideal magnetohydrodynamics is derived for an unipolar asymmetric sunspot immersed in a realistic solar atmosphere. The radial and vertical profiles of pressure, plasma density, and temperature in the visible layers of the sunspot are calculated. The reduction in plasma density in the magnetic funnel of the sunspot, corresponding to the Wilson depression, is also obtained. The magnetic structure of the sunspot is given analytically in a realistic way: a part of the magnetic flux of the sunspot approaches the surrounding photosphere at the outer edge of the penumbra. The magnetic field of the sunspot is not assumed to be axially symmetric. For the first time, the angular dependence of the physical variables in this model allows us to simulate not only a deviation from the circular shape of the sunspot, but also a fine filamentary structure of the sunspot penumbra. The Alfvén Mach number (the ratio of the plasma speed to the Alfvén speed) is zero at the center of the sunspot and rises slowly toward the periphery of the sunspot; this corresponds to the structure of the Evershed flow in the penumbra. The Evershed flow in our model is mainly concentrated in dark penumbral filaments, as is observed.

  19. Nanopeptamers for the development of small-analyte lateral flow tests with a positive readout.

    Science.gov (United States)

    Vanrell, Lucía; Gonzalez-Techera, Andrés; Hammock, Bruce D; Gonzalez-Sapienza, Gualberto

    2013-01-15

    There is a great demand for rapid tests that can be used on-site for the detection of small analytes, such as pesticides, persistent organic pollutants, explosives, toxins, medicinal and abused drugs, hormones, etc. Dipsticks and lateral flow devices, which are simple and provide a visual readout, may be the answer, but the available technology for these compounds requires a competitive format that loses sensitivity and produces readings inversely proportional to the analyte concentration, which is counterintuitive and may lead to potential misinterpretation of the result. In this work, protein-multipeptide constructs composed of anti-immunocomplex peptides selected from phage libraries and streptavidin/avidin as core protein were used for direct detection of small compounds in a noncompetitive two-site immunoassay format that performs with increased sensitivity and positive readout. These constructs that we termed "nanopeptamers" allow the development of rapid point-of-use tests with a positive visual end point of easy interpretation. As proof of concept, lateral flow assays for the herbicides molinate and clomazone were developed and their performance was characterized with field samples.

  20. Analytical solutions of heat transfer for laminar flow in rectangular channels

    Science.gov (United States)

    Rybiński, Witold; Mikielewicz, Jarosław

    2014-12-01

    The paper presents two analytical solutions namely for Fanning friction factor and for Nusselt number of fully developed laminar fluid flow in straight mini channels with rectangular cross-section. This type of channels is common in mini- and microchannel heat exchangers. Analytical formulae, both for velocity and temperature profiles, were obtained in the explicit form of two terms. The first term is an asymptotic solution of laminar flow between parallel plates. The second one is a rapidly convergent series. This series becomes zero as the cross-section aspect ratio goes to infinity. This clear mathematical form is also inherited by the formulae for friction factor and Nusselt number. As the boundary conditions for velocity and temperature profiles no-slip and peripherally constant temperature with axially constant heat flux were assumed (H1 type). The velocity profile is assumed to be independent of the temperature profile. The assumption of constant temperature at the channel's perimeter is related to the asymptotic case of channel's wall thermal resistance: infinite in the axial direction and zero in the peripheral one. It represents typical conditions in a minichannel heat exchanger made of metal.

  1. Analytical applications of a carbon nanotubes composite modified with copper microparticles as detector in flow systems.

    Science.gov (United States)

    Arribas, Alberto Sánchez; Bermejo, Esperanza; Chicharro, Manuel; Zapardiel, Antonio; Luque, Guillermina L; Ferreyra, Nancy F; Rivas, Gustavo A

    2006-09-08

    In this work we report on the successful use of a composite prepared by dispersion of multi-wall carbon nanotubes (1-5 microm length, 20-50 nm diameter) and copper microparticles within mineral oil as detector for amino acids quantification in flow injection analysis and capillary electrophoresis. The resulting electrode displays a highly sensitive amperometric detection of amino acids, based on the copper dissolution facilitated by the strong activity of amino acids as ligands of Cu(II). The sensor makes possible the detection of amino acids, electroactive or not, at very low potentials (0.000 V) and physiological pH. A correlation between the sensitivity for the amino acids and the amount of copper within the composite is observed, demonstrating the importance of the metal in the sensor response. The best analytical performance is obtained for the electrode containing 12.0% (w/w) copper. The excellent results obtained with the carbon nanotube paste electrodes containing copper (CNTPE-Cu) as detector in flow systems makes them an interesting alternative for further analytical applications involving different bioanalytes.

  2. Analytical solutions for the flow fields near funnel-and-gate reactive barriers with hydraulic losses

    Science.gov (United States)

    Klammler, Harald; Hatfield, Kirk

    2009-02-01

    Permeable reactive barriers (PRBs) are a passive in situ technology that is based on the interception and physical, chemical, and/or biological remediation of a contaminant plume through installation of reactive material in an aquifer. The present work is an extension and generalization of a previous paper and derives analytical expressions for flow fields toward PRBs in two dimensions on the basis of the conformal mapping approach. Considered is the classic funnel-and-gate configuration with perpendicular funnel arms (PFGs) as well as PRBs with velocity equalization walls. While the aquifer is assumed to be homogeneous in a uniform far field, the hydraulic conductivity of the reactive material is allowed to take arbitrary values above or below the aquifer conductivity. At the up- and down-gradient interfaces between reactor and aquifer, highly permeable gravel packs are assumed to establish constant head conditions. The flow fields are analyzed regarding the widths and shapes of respective capture zones as functions of PRB type and dimensions, reactor hydraulic resistance (including flow divergence and longevity), and ambient groundwater flow direction. Expressions for discharge fields are developed as needed for particle-tracking algorithms. Charts of relative capture width are given to facilitate PRB design and may be included in more comprehensive PRB design/optimization approaches. An efficient approach is presented to estimate reactor conductivity and capture flow from monitoring the hydraulic loss at the reactor. Inherent assumptions and results are validated against numerical flow field solutions and water level field data for the PFG PRB at the Moffett Federal Airfield, California.

  3. EFFECT OF HYDRAULIC AND GEOMETRICAL PROPERTIES ON STEPPED CASCADE AERATION SYSTEM

    Directory of Open Access Journals (Sweden)

    VEDHACHALAM RATHINAKUMAR

    2017-03-01

    Full Text Available Stepped cascade aeration system is commonly used to aerate the water and wastewater to increase the dissolved oxygen during pre and post treatment process. In the present research, experiments were conducted to evaluate the performance of a rectangular Cascade Aeration System with varying flow rates, risers and tread by maintaining constant width of the channel using water collected from reverse osmosis plant. The experiments were carried out with four different risers such as 0.15 m, 0.18 m, 0.225 m and 0.30 m. Each rise was investigated with five different tread of 0.60 m, 0.55 m, 0.50 m, 0.45 m and 0.40 m. Comprehensive experimental investigations were carried out for different hydraulic loading rates of 0.005 to 0.035 m3/s/m2. Results obtained from the experiments reveals that increasing dimensionless discharges promotes more aeration, attains a maximum up to dimensionless discharge= 2.22 and beyond this there was a significant decrease in aeration. In addition, the increased in number of steps significantly enhances air entertainment and surface fall rate in the Stepped Cascade Aeration System. A regression equation was derived by keeping aeration efficiency as response with dimensionless discharge and oxygen saturation concentration as influencing parameters. The dimension less discharge is a function of critical depth of the rectangular channel and step height, whereas oxygen saturation concentration represents the ratio of oxygen deficit and oxygen saturation concentration. Based on the experimental results, the optimum design and/or results such as number of steps (12 numbers and hydraulic loading rate (0.025 m3/s/m2 with fixed tread width of 0.6 m were identified to achieve maximum aeration rate (0.5-0.60 in Aeration system.

  4. An Explicit,Totally Analytic Solution of Laminar Viscous FLow over a Semi—Infinite Flat Plate

    Institute of Scientific and Technical Information of China (English)

    Shi-JunLIAO

    1998-01-01

    In this paper,a new kind of analytic technique for nonlinear problems,namely the Homotopy Analysis Method,is applied to give an explicit,totally analytic solution of the Blasius' flow.i.e.,the two dimensional (2D) laminar viscous flow over a semi-infinite flat plate.This analytic solution is valid in the whole region having physical meanings.To our knowledge,it is the first time in history that such a kind of explicit,totally analytic solution is given.This fact well verifies the great potential and validity of the Honmotopy Analysis Method as a kind of powerful analytic tool for nonlinear problems in science and engineering.

  5. Continuous-flow multi-analyte biosensor cartridge with controllable linear response range.

    Science.gov (United States)

    Frey, Olivier; Talaei, Sara; van der Wal, Peter D; Koudelka-Hep, Milena; de Rooij, Nico F

    2010-09-01

    This article presents the design and fabrication of a microfluidic biosensor cartridge for the continuous and simultaneous measurement of biologically relevant analytes in a sample solution. The biosensor principle is based on the amperometric detection of hydrogen peroxide using enzyme-modified electrodes. The low-integrated and disposable cartridge is fabricated in PDMS and SU-8 by rapid prototyping. The device is designed in such a way that it addresses two major challenges of biosensors using microfluidics approaches. Firstly, the enzymatic membrane is deposited on top of the platinum electrodes via a microfluidic deposition channel from outside the cartridge. This decouples the membrane deposition from the cartridge fabrication and enables the user to decide when and with what mixture he wants to modify the electrode. Secondly, by using laminar sheath-flow of the sample and a buffer solution, a dynamic diffusion layer is created. The analyte has to diffuse through the buffer solution layer before it can reach the immobilized enzyme membrane on the electrode. Controlling of the thickness of the diffusion layer by variation of the flow-rate of the two layers enables the user to adjust the sensitivity and the linear region of the sensor. The point where the buffer and sample stream join proved critical in creating the laminar sheath-flow. Results of computational simulations considering fluid dynamics and diffusion are presented. The consistency of the device was investigated through detection of glucose and lactate and are in accordance with the CFD simulations. A sensitivity of 157+/-28 nA/mM for the glucose sensor and 79+/-12 nA/mM for the lactate sensor was obtained. The linear response range of these biosensors could be increased from initially 2 mM up to 15 mM with a limit of detection of 0.2 mM.

  6. Hydraulic characteristics of converse curvature section and aerator in high-head and large discharge spillway tunnel

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    The hydraulic characteristics and cavitation erosion near the converse curvature section in the high-head and large discharge spillway tunnel have been important issues of concern to the hydropower project.In this paper,the evolutions of hydraulic elements such as pressure,flow velocity,wall shear stress,etc.in the converse curvature section are analyzed and the impacts of bottom aerator on hydraulic characteristics are discussed,with the commercial software FLUENT6.3 as a platform and combining the k-model and VOF method.The flow pattern in the converse curvature section of spillway tunnel is given by the three-dimensional numerical simulation.It indicates that the pressure changes rapidly with great pressure gradient from the beginning to the end of the curve.It also shows that the shear stress on side wall just downstream the end of the converse curvature curve is still increasing;the aeration cavity formed downstream the bottom aerator may cause the side wall pressure decreased to worsen the cavitation characteristics near the side wall.By means of the physical model experiment,the three-dimensional aerator composed of side wall baffling aerator and bottom aerator is studied,the baffling aerator suitable for the water flow conditions with water depth of 6.0 to 8.0 m and flow velocity of 35 to 50 m/s is proposed.

  7. Pump-and-treat optimization using analytic element method flow models

    Science.gov (United States)

    Matott, L. Shawn; Rabideau, Alan J.; Craig, James R.

    2006-05-01

    Plume containment using pump-and-treat (PAT) technology continues to be a popular remediation technique for sites with extensive groundwater contamination. As such, optimization of PAT systems, where cost is minimized subject to various remediation constraints, is the focus of an important and growing body of research. While previous pump-and-treat optimization (PATO) studies have used discretized (finite element or finite difference) flow models, the present study examines the use of analytic element method (AEM) flow models. In a series of numerical experiments, two PATO problems adapted from the literature are optimized using a multi-algorithmic optimization software package coupled with an AEM flow model. The experiments apply several different optimization algorithms and explore the use of various pump-and-treat cost and constraint formulations. The results demonstrate that AEM models can be used to optimize the number, locations and pumping rates of wells in a pump-and-treat containment system. Furthermore, the results illustrate that a total outflux constraint placed along the plume boundary can be used to enforce plume containment. Such constraints are shown to be efficient and reliable alternatives to conventional particle tracking and gradient control techniques. Finally, the particle swarm optimization (PSO) technique is identified as an effective algorithm for solving pump-and-treat optimization problems. A parallel version of the PSO algorithm is shown to have linear speedup, suggesting that the algorithm is suitable for application to problems that are computationally demanding and involve large numbers of wells.

  8. A semi-analytical model for the flow behavior of naturally fractured formations with multi-scale fracture networks

    Science.gov (United States)

    Jia, Pin; Cheng, Linsong; Huang, Shijun; Wu, Yonghui

    2016-06-01

    This paper presents a semi-analytical model for the flow behavior of naturally fractured formations with multi-scale fracture networks. The model dynamically couples an analytical dual-porosity model with a numerical discrete fracture model. The small-scale fractures with the matrix are idealized as a dual-porosity continuum and an analytical flow solution is derived based on source functions in Laplace domain. The large-scale fractures are represented explicitly as the major fluid conduits and the flow is numerically modeled, also in Laplace domain. This approach allows us to include finer details of the fracture network characteristics while keeping the computational work manageable. For example, the large-scale fracture network may have complex geometry and varying conductivity, and the computations can be done at predetermined, discrete times, without any grids in the dual-porosity continuum. The validation of the semi-analytical model is demonstrated in comparison to the solution of ECLIPSE reservoir simulator. The simulation is fast, gridless and enables rapid model setup. On the basis of the model, we provide detailed analysis of the flow behavior of a horizontal production well in fractured reservoir with multi-scale fracture networks. The study has shown that the system may exhibit six flow regimes: large-scale fracture network linear flow, bilinear flow, small-scale fracture network linear flow, pseudosteady-state flow, interporosity flow and pseudoradial flow. During the first four flow periods, the large-scale fracture network behaves as if it only drains in the small-scale fracture network; that is, the effect of the matrix is negligibly small. The characteristics of the bilinear flow and the small-scale fracture network linear flow are predominantly determined by the dimensionless large-scale fracture conductivity. And low dimensionless fracture conductivity will generate large pressure drops in the large-scale fractures surrounding the wellbore. With

  9. A splitting technique for analytical modelling of two-phase multicomponent flow in porous media

    DEFF Research Database (Denmark)

    Pires, A.P.; Bedrikovetsky, P.G.; Shapiro, Alexander

    2006-01-01

    In this paper we discuss one-dimensional models for two-phase Enhanced Oil Recovery (EOR) floods (oil displacement by gases, polymers, carbonized water, hot water, etc.). The main result presented here is the splitting of the EOR mathematical model into thermodynamical and hydrodynamical parts....... The introduction of a potential associated with one of the conservation laws and its use as a new independent coordinate reduces the number of equations by one. The (n)x(n) conservation law model for two-phase n-component EOR flows in new coordinates is transformed into a reduced (n-1)x(n-1) auxiliary system...... containing just thermodynamical variables (equilibrium fractions of components, sorption isotherms) and one lifting equation containing just hydrodynamical parameters (phase relative permeabilities and viscosities). The algorithm to solve analytically the problem includes solution of the reduced auxiliary...

  10. Rapid Determination of Optimal Conditions in a Continuous Flow Reactor Using Process Analytical Technology

    Directory of Open Access Journals (Sweden)

    Michael F. Roberto

    2013-12-01

    Full Text Available Continuous flow reactors (CFRs are an emerging technology that offer several advantages over traditional batch synthesis methods, including more efficient mixing schemes, rapid heat transfer, and increased user safety. Of particular interest to the specialty chemical and pharmaceutical manufacturing industries is the significantly improved reliability and product reproducibility over time. CFR reproducibility can be attributed to the reactors achieving and maintaining a steady state once all physical and chemical conditions have stabilized. This work describes the implementation of a smart CFR with univariate physical and multivariate chemical monitoring that allows for rapid determination of steady state, requiring less than one minute. Additionally, the use of process analytical technology further enabled a significant reduction in the time and cost associated with offline validation methods. The technology implemented for this study is chemistry and hardware agnostic, making this approach a viable means of optimizing the conditions of any CFR.

  11. Analytical solutions for flow of horizontal well in compressible, three-dimensional unconsolidated formations

    Science.gov (United States)

    Zhao, Yu-Long; Zhang, Lie-Hui; Chen, Jun; Li, Long-Xin; Zhou, Yuan

    2014-08-01

    A novel mathematical model for single-phase fluid flow from unconsolidated formations to a horizontal well with the consideration of stress-sensitive permeability is presented. The model assumes the formation permeability is an exponential function of the pore pressure. Using a perturbation technique, the model is solved for either constant pressure or constant flux or infinite lateral boundary conditions with closed top and bottom boundaries. Through Laplace transformation, finite Fourier transformation and numerical inversion methods, the solutions are obtained and the pressure response curves are analyzed. The agreement between the analytical solutions in this paper and the numerical results from commercial software (Saphir) is excellent, which manifests the accuracy of the results derived in this paper.

  12. Transient flow between aquifers and surface water: analytically derived field-scale hydraulic heads and fluxes

    Directory of Open Access Journals (Sweden)

    G. H. de Rooij

    2012-03-01

    Full Text Available The increasing importance of catchment-scale and basin-scale models of the hydrological cycle makes it desirable to have a simple, yet physically realistic model for lateral subsurface water flow. As a first building block towards such a model, analytical solutions are presented for horizontal groundwater flow to surface waters held at prescribed water levels for aquifers with parallel and radial flow. The solutions are valid for a wide array of initial and boundary conditions and additions or withdrawals of water, and can handle discharge into as well as lateral infiltration from the surface water. Expressions for the average hydraulic head, the flux to or from the surface water, and the aquifer-scale hydraulic conductivity are developed to provide output at the scale of the modelled system rather than just point-scale values. The upscaled conductivity is time-variant. It does not depend on the magnitude of the flux but is determined by medium properties as well as the external forcings that drive the flow. For the systems studied, with lateral travel distances not exceeding 10 m, the circular aquifers respond very differently from the infinite-strip aquifers. The modelled fluxes are sensitive to the magnitude of the storage coefficient. For phreatic aquifers a value of 0.2 is argued to be representative, but considerable variations are likely. The effect of varying distributions over the day of recharge damps out rapidly; a soil water model that can provide accurate daily totals is preferable over a less accurate model hat correctly estimates the timing of recharge peaks.

  13. Granular Flow Dynamics on Earth, Moon, and Mars from analytical, numerical and field analysis

    Science.gov (United States)

    Lucas, A.; Mangeney, A.; Mhge, D.

    2010-12-01

    Prediction of landslides dynamics remains difficult in spite of a considerable body of work. A number of previous studies have been based on runout analysis in relation to mean dissipation calibration via the friction coefficient. However, the shape of the initial scar is generally unknown in real cases, which weakens landslide material spreading predictions and has alters calibration parameters of numerical models. We study numerically the effects of scar geometry on flow and distribution of the deposits and show that the initial shape of the scar, independent of the friction coefficient, does not affect the runout distance. In contrast, 3D tests show that the shape of the final deposits is a function of the scar geometry, and hence information on initial scar geometry and initial volume involved in the mass spreading may be retrieved from analysis of final deposit morphology. From an analytical solution we show here why the classical mobility (defined as the ratio between total height and runout distance) decreases when the volume increases, as is generally observed in geological data. We thus introduce analytically a new mobility variable obtained from geomorphic measurements reflecting the intrinsic dissipation independent of the aspect ratio, of the volume of the granular mass involved, of the underlying topography, and of the initial scar geometry. Comparison between experimental results, terrestrial, Lunar and Martian cases highlights a larger new mobility measure of natural granular flows compared to dry mass spreading simulated in the laboratory. In addition, landslides in a similar geological context give a single value showing the robustness of this new parameter. Finally, the new mobility provides a first order estimate of the effective friction required in models to reproduce the extent of the deposits in a given geological context. This enables a feedback analysis method for retrieving the volume and shape of the initial landslide material and then

  14. BIOVENTING - Groundwater Aeration by Discontinuous Oxygen Gas Pulse Injections

    Science.gov (United States)

    Schirmer, M.

    2003-12-01

    to cis,cis-2-chloromuconate is demonstrated. In order to examine effects of enhanced natural attenuation, initiated by aeration, on geohydraulics, discontinuous oxygen gas injections were simulated in two flow-through systems. Design, processing, and first results of our ongoing research are presented for the automatized lab column system CAMERA and a pilot field reactor at a MCB polluted site at Bitterfeld, Germany. Bubble mediated oxygen gas transfer is briefly discussed in light of the model presented recently by Holocher (Environ. Sci. Technol., 2003. 37: p. 1337-1343).

  15. ON NECESSITY OF PLACING AN AERATOR IN THE BOTTOM DISCHARGE TUNNEL AT THE LONGTAN HYDROPOWER STATION

    Institute of Scientific and Technical Information of China (English)

    WU Jian-hua; WU Wei-wei; RUAN Shi-ping

    2006-01-01

    The air entrainment for avoiding cavitation damage has been widely used in long free flow tunnels. It is crucial to determine whether an aerator is needed for shorter tunnels. In this article, the bottom discharge tunnel at the Longtan Hydropower Station was involved, for which the free flow tunnel section was only 50.00 m long. The cavitation in the tunnel with and without the aerator was investigated using the physical models of the scale 1/30, through the measurements of cavitation noise. The experimental results show that it is necessary to place the aerator at the inlet of the free flow section for higher reservoir level to protect this tunnel from cavitation damage.

  16. A study on transformation of main pollutants along the wastewater flow in biological aerated filter%海水曝气生物滤器污染物沿程转化规律的研究

    Institute of Scientific and Technical Information of China (English)

    张延青; 陈江萍; 沈加正; 侯沙沙; 刘杨; 刘鹰

    2011-01-01

    The performances of biological aerated filter (BAF) with hollow bamboo balls as filter media for wastewater treatment in marine aquaculture was investigated. The wastewater was conditioned at pH ranging from 7.8-8.0, DO ranging from 2.8~5.8mg/L, air-to-water ratio at 3, hydraulic load of 0.58m3/(m3h), TAN load of 0.35~0.46g/(m3·h), and organic load of 1.58g/(m3h). Transformation of organic substances and ammonia nitrogen along the water flow were evaluated to determine the spatial distribution characteristics of pollutants. Results showed that most CODMn was removed between 0-10cm height, with 49.12% CODmn removed and 34.88% soluble CODMn removed in this range, meanwhile most TAN removed between 0-30cm height, with 18% TAN removed at 10cm and 55% removed at 30cm. The biomass and microbial activity decreased from the bottom of the filter to the top. In conclusion, pollutants were mainly removed between the height of 0~30cm, and the left section of the filter always acted as a buffer to remove pollutants remained in the wastewater, in case of sudden waste load or hydraulic impact.%以竹制空心生化球填料生物滤器处理海水养殖废水为对象,在水力负荷为0.58m3/[m3(填料)·h]、氨氮负荷为(0.35~046)g/[m3(填料)·h]、有机负荷约为11.58g/[m3(填料)·h]、气水比3∶1、pH值为7.8~8.0、DO浓度2.8~5.8mg/L的条件下,考察了有机物和总氨氮(TAN)的沿程转化规律,分析了污染物的空间分布特性.结果表明:在给定的运行条件下,CODMn的主要去除区间在滤器的0~10cm高度,其中CODMn和溶解性CODMn在此处的去除率分别为49.12%和34.88%;TAN的主要去除区间为0~30cm,其中10cm处TAN的去除率为18%,30cm处为55%;生物量和生物活性由下向上呈递减的分布趋势;生物滤器污染物的主要去除区间为0~30cn,受到水质、水量冲击时,较高层的填料(30~60cm)起到了缓冲作用,将下层生物膜未能降解的污染物去除.

  17. Ecophysiology of wetland plant roots: A modelling comparison of aeration in relation to species distribution

    Science.gov (United States)

    Sorrell, B.K.; Mendelssohn, I.A.; McKee, K.L.; Woods, R.A.

    2000-01-01

    This study examined the potential for inter-specific differences in root aeration to determine wetland plant distribution in nature. We compared aeration in species that differ in the type of sediment and depth of water they colonize. Differences in root anatomy, structure and physiology were applied to aeration models that predicted the maximum possible aerobic lengths and development of anoxic zones in primary adventitious roots. Differences in anatomy and metabolism that provided higher axial fluxes of oxygen allowed deeper root growth in species that favour more reducing sediments and deeper water. Modelling identified factors that affected growth in anoxic soils through their effects on aeration. These included lateral root formation, which occurred at the expense of extension of the primary root because of the additional respiratory demand they imposed, reducing oxygen fluxes to the tip and stele, and the development of stelar anoxia. However, changes in sediment oxygen demand had little detectable effect on aeration in the primary roots due to their low wall permeability and high surface impedance, but appeared to reduce internal oxygen availability by accelerating loss from laterals. The development of pressurized convective gas flow in shoots and rhizomes was also found to be important in assisting root aeration, as it maintained higher basal oxygen concentrations at the rhizome-root junctions in species growing into deep water. (C) 2000 Annals of Botany Company.

  18. Scale-up criterion of power consumption for a surface aerator used in wastewater treatment tank

    Directory of Open Access Journals (Sweden)

    Hayder M. Issa

    2016-01-01

    Full Text Available The major part of operation costs in surface aeration basins or tanks is because of power requirements. Therefore, it is always necessary to find a dependable criterion for the predictive scale-up of power consumption measurements obtained at laboratory-scale surface aeration tanks to industrial-scale wastewater treatment surface aeration systems. A scale-up approach was proposed in this work for volumetric power consumption between geometrically similar laboratory-scale and industrial full-scale surface aeration tanks at an invariant Froude number Fr. Scale-up order between the laboratory and industrial sizes was 7.4. A mathematical correlation has been developed to estimate the volumetric power consumption and then compared with a model that already was investigated experimentally. Scale-up criterion involved the evaluation of three similarities; the geometrical, kinematic and dynamics. The scale-up basis that developed in this work led us to achieve a suitable scale-up criterion for volumetric power consumption in aeration tanks at matched surface flow condition. At matched Froude number Fr for the laboratory and industrial scales and at low and moderate turbine rotation speeds for surface aeration than 0.8 rps, complete predictions of volumetric power consumption have been achieved. The prediction by the existing previous model showed higher results than the actual values.

  19. Aerated lagooning of agro-industrial wastewater: depuration performance and energy requirements

    Directory of Open Access Journals (Sweden)

    Serafina Andiloro

    2013-09-01

    Full Text Available Intensive depuration plants have often shown low reliability and economic sustainability, when utilised for agro-industrial wastewater treatment, due to the particular wastewater properties: high organic load and essential oil concentrations, acidity, nutrient scarcity and qualitative-quantitative variability of effluents. Aerated lagooning systems represent a suitable alternative, because they are able to assure good reliability and low energy requirements, avoiding the drawbacks shown by the intensive depuration plants. In order to optimize performance of the lagooning systems, particularly in terms of energy requirements, depuration processes of aerobic-anaerobic aerated lagoons were investigated, both at full- and laboratory-scale. Citrus processing wastewater were subject to bubble aeration with low flow rates and limited time; the removal rate of organic load was evaluated and energy requirements of different depuration schemes were compared. The experimental investigations in full-scale aerated lagoons showed a low energy supply (0.21-0.59 kWh per kg of COD (Chemical Oxygen Demand removed with an average value of 0.45 kWh kgCOD –1, an adequate equalisation capability and constantly good depurative performance also with high concentrations of essential oil (500-1000 ppm. The experimental investigations in lab-scale aerated tanks under controlled conditions indicated the possibility of decreasing energy requirements (down to 0.16 kWh kgCOD –1 by reducing aeration power (down to 0.6 W m–3 and limiting aeration time to night 12 hours only, when energy price is lower. In spite of the low aeration, the COD removal rates were on the average six-fold higher compared to the anaerobic tank. Other outcomes indicated an ability of the spontaneous microflora to adapt to high concentrations of essential oils, which however did not provide an increase of the removal rate of the organic load in the experimented scheme.

  20. A study on evaluation and analytical methods for groundwater flow with considering sea/fresh-water boundary. 1

    Energy Technology Data Exchange (ETDEWEB)

    Anezaki, S. [Taisei Corp., Tokyo (Japan)

    1998-03-01

    Sea/fresh-water boundary caused by density and concentration balance of sea-water and fresh-water is an important item for groundwater flow evaluation in deep underground near the coast. Also, in order to evaluate groundwater quality, it is important to understand the characteristics of sea/fresh-water boundary, for example boundary shape, salt distribution. In order to establish the evaluation and analytical methods for groundwater flow with considering sea/fresh-water boundary, we investigated the following items in this study. (1) Literature survey and data collection. (2) Investigation of analytical methods. (3) Planning of further study. (author). 78 refs.

  1. Winery Wastewater Treatment Applying Aerated Submerged

    Directory of Open Access Journals (Sweden)

    Alessandra Pellizzaro Bento

    2010-06-01

    Full Text Available The winery wastewater usually shows conditions of low pH, high organic loads and concentrations of carbon, nitrogen and phosphorus that are inappropriate for biologic treatment. The purpose of this research was to apply the technology of aerated submerged biofilter (ASB for the winery effluent treatment during the harvest (ASB 1 and non harvest (ASB 2 at lab scale. Therefore, two up flow biofilter built on glass (5 liters volume were installed. The nutrient balance of the winery wastewater was adjusted and the correction of the pH was done by oyster shell used as filter material. The efficiency removal (COD for the harvest reactor was 90% while for the non harvest was 82%. The oyster shells contributed to an increase on average of 180 mg/L of alkalinity to the BAS 1 and 318 mg/L for the BAS 2. As regards the metals, the average values in the treated effluent to meet iron and zinc is permitted by the environmental standards of Santa Catarina. Under the experimental conditions applied in this research, this kind of reactor has presented potential for the treatment of winery wastewater. However, operational improvements would be required in the reactors to adequate them to the specific management into the wineries.

  2. Aerator Selection in Pulping & Papermaking Wastewater Treatment Engineering%造纸废水处理工程曝气器优选

    Institute of Scientific and Technical Information of China (English)

    王少艮; 张会敏

    2013-01-01

    The characteristics and application scopes of existing aeration equipment used in pulping and papermaking wastewater treatment, such as blasting aerator, jet aerator and mechanical aerator were summarized in this paper. To avoid the disadvantage of the existing aeration system, an innovational rotational flow aerator was introduced, and its advantage and engineering examples were discussed.%讨论了现有曝气设备,包括鼓风曝气、射流曝气和机械曝气设备的特点及适用范围,针对现有曝气器在造纸废水应用中的不足,系统介绍了新型高效旋流曝气器的特征及其在造纸废水处理中的应用优势和工程实例.

  3. DESIGN INFORMATION ON FINE PORE AERATION SYSTEMS

    Science.gov (United States)

    Field studies were conducted over several years at municipal wastewater treatment plants employing line pore diffused aeration systems. These studies were designed to produce reliable information on the performance and operational requirements of fine pore devices under process ...

  4. Oxygen demand for the stabilization of the organic fraction of municipal solid waste in passively aerated bioreactors

    Energy Technology Data Exchange (ETDEWEB)

    Kasinski, Slawomir, E-mail: slawomir.kasinski@uwm.edu.pl; Wojnowska-Baryla, Irena

    2014-02-15

    Highlights: • The use of an passively aerated reactor enables effective stabilization of OFMSW. • Convective air flow does not inhibit the aerobic stabilization of waste. • The use of an passively aerated reactor reduces the heat loss due to convection. • The volume of supplied air exceeds 1.7–2.88 times the microorganisms demand. - Abstract: Conventional aerobic waste treatment technologies require the use of aeration devices that actively transport air through the stabilized waste mass, which greatly increases operating costs. In addition, improperly operated active aeration systems, may have the adverse effect of cooling the stabilized biomass. Because active aeration can be a limiting factor for the stabilization process, passive aeration can be equally effective and less expensive. Unfortunately, there are few reports documenting the use of passive aeration systems in municipal waste stabilization. There have been doubts raised as to whether a passive aeration system provides enough oxygen to the organic matter mineralization processes. In this paper, the effectiveness of aeration during aerobic stabilization of four different organic fractions of municipal waste in a reactor with an integrated passive ventilation system and leachate recirculation was analyzed. For the study, four fractions separated by a rotary screen were chosen. Despite the high temperatures in the reactor, the air flow rate was below 0.016 m{sup 3}/h. Using Darcy’s equation, theoretical values of the air flow rate were estimated, depending on the intensity of microbial metabolism and the amount of oxygen required for the oxidation of organic compounds. Calculations showed that the volume of supplied air exceeded the microorganisms demand for oxidation and endogenous activity by 1.7–2.88-fold.

  5. Oxygen transfer in circular surface aeration tanks.

    Science.gov (United States)

    Rao, Achanta Ramakrishna; Patel, Ajey Kumar; Kumar, Bimlesh

    2009-06-01

    Surface aeration systems employed in activated sludge plants are the most energy-intensive units of the plants and typically account for a higher percentage of the treatment facility's total energy use. The geometry of the aeration tank imparts a major effect on the system efficiency. It is said that at optimal geometric conditions, systems exhibits the maximum efficiency. Thus the quantification of the optimal geometric conditions in surface aeration tanks is needed. Optimal geometric conditions are also needed to scale up the laboratory result to the field installation. In the present work, experimental studies have been carried out on baffled and unbaffled circular surface aeration tanks to ascertain the optimal geometric conditions. It is found that no optimal geometric conditions exist for the liquid/water depth in circular surface aeration tanks; however, for design purposes, a standard value has been assumed. Based on the optimal geometric conditions, a scale-up equation has been developed for the baffled circular surface aeration tanks.

  6. Reducing aeration energy consumption in a large-scale membrane bioreactor: Process simulation and engineering application.

    Science.gov (United States)

    Sun, Jianyu; Liang, Peng; Yan, Xiaoxu; Zuo, Kuichang; Xiao, Kang; Xia, Junlin; Qiu, Yong; Wu, Qing; Wu, Shijia; Huang, Xia; Qi, Meng; Wen, Xianghua

    2016-04-15

    Reducing the energy consumption of membrane bioreactors (MBRs) is highly important for their wider application in wastewater treatment engineering. Of particular significance is reducing aeration in aerobic tanks to reduce the overall energy consumption. This study proposed an in situ ammonia-N-based feedback control strategy for aeration in aerobic tanks; this was tested via model simulation and through a large-scale (50,000 m(3)/d) engineering application. A full-scale MBR model was developed based on the activated sludge model (ASM) and was calibrated to the actual MBR. The aeration control strategy took the form of a two-step cascaded proportion-integration (PI) feedback algorithm. Algorithmic parameters were optimized via model simulation. The strategy achieved real-time adjustment of aeration amounts based on feedback from effluent quality (i.e., ammonia-N). The effectiveness of the strategy was evaluated through both the model platform and the full-scale engineering application. In the former, the aeration flow rate was reduced by 15-20%. In the engineering application, the aeration flow rate was reduced by 20%, and overall specific energy consumption correspondingly reduced by 4% to 0.45 kWh/m(3)-effluent, using the present practice of regulating the angle of guide vanes of fixed-frequency blowers. Potential energy savings are expected to be higher for MBRs with variable-frequency blowers. This study indicated that the ammonia-N-based aeration control strategy holds promise for application in full-scale MBRs.

  7. Hydrolytic anaerobic reactor and aerated constructed wetland systems for municipal wastewater treatment - HIGHWET project.

    Science.gov (United States)

    Pascual, A; de la Varga, D; Arias, C A; Van Oirschot, D; Kilian, R; Álvarez, J A; Soto, M

    2017-01-01

    The HIGHWET project combines the hydrolytic up-flow sludge bed (HUSB) anaerobic digester and constructed wetlands (CWs) with forced aeration for decreasing the footprint and improving effluent quality. The HIGHWET plant in A Coruña (NW of Spain) treating municipal wastewater consists of a HUSB and four parallel subsurface horizontal flow (HF) CWs. HF1, HF2 and HF3 units are fitted with forced aeration, while the control HF4 is not aerated. All the HF units are provided with effluent recirculation, but different heights of gravel bed (0.8 m in HF1 and HF2, and 0.5 m in HF3 and HF4) are implemented. Besides, a tobermorite-enriched material was added in the HF2 unit in order to improve phosphorus removal. The HUSB 76-89% of total suspended solids (TSS) and about 40% of chemical oxygen demand (COD) and biological oxygen demand (BOD). Aerated HF units reached above 96% of TSS, COD and BOD at a surface loading rate of 29-47 g BOD5/m(2)·d. An aeration regime ranging from 5 h on/3 h off to 3 h on/5 h off was found to be adequate to optimize nitrogen removal, which ranged from 53% to 81%. Average removal rates of 3.4 ± 0.4 g total nitrogen (TN)/m(2)·d and 12.8 ± 3.7 g TN/m(3)·d were found in the aerated units, being 5.5 and 4.1 times higher than those of the non-aerated system. The tobermorite-enriched HF2 unit showed a distinct higher phosphate (60-67%) and total phosphorus (54%) removal.

  8. Comment on 'Application of the homotopy method for analytical solution of non-Newtonian channel flows'

    Energy Technology Data Exchange (ETDEWEB)

    Lipscombe, T C [Johns Hopkins University, 2715 North Charles Street, Baltimore, MD 21218 (United States)], E-mail: tcl@press.jhu.edu

    2010-03-15

    We solve exactly the Poiseuille and Couette flows of a non-Newtonian fluid discussed by Roohi et al (2009 Phys. Scr. 79 065009) and thereby show that the approximate analytical solutions provided by the homotopy method must be used with caution.

  9. An analytical-based method for studying the nonlinear evolution of localized vortices in planar homogenous shear flows

    Science.gov (United States)

    Cohen, J.; Shukhman, I. G.; Karp, M.; Philip, J.

    2010-10-01

    Recent experimental and numerical studies have shown that the interaction between a localized vortical disturbance and the shear of an external base flow can lead to the formation of counter-rotating vortex pairs and hairpin vortices that are frequently observed in wall bounded and free turbulent shear flows as well as in subcritical shear flows. In this paper an analytical-based solution method is developed. The method is capable of following (numerically) the evolution of finite-amplitude localized vortical disturbances embedded in shear flows. Due to their localization in space, the surrounding base flow is assumed to have homogeneous shear to leading order. The method can solve in a novel way the interaction between a general family of unbounded planar homogeneous shear flows and any localized disturbance. The solution is carried out using Lagrangian variables in Fourier space which is convenient and enables fast computations. The potential of the method is demonstrated by following the evolved structures of large amplitude disturbances in three canonical base flows, including simple shear, plane stagnation (extensional) and pure rotation flows, and a general case. The results obtained by the current method for plane stagnation and simple shear flows are compared with the published results. The proposed method could be extended to other flows (e.g. geophysical and rotating flows) and to include periodic disturbances as well.

  10. Effect of Borehole Material on Analytical Solutions of the Heat Transfer Model of Ground Heat Exchangers Considering Groundwater Flow

    Directory of Open Access Journals (Sweden)

    Sangwoo Park

    2016-04-01

    Full Text Available Groundwater flow is one of the most important factors for the design of a ground heat exchanger (GHEX since the thermal environment of the ground around the buried GHEX is significantly affected by heat convection due to the groundwater flow. Several preceding studies have been conducted to develop analytical solutions to the heat transfer model of GHEX with consideration of groundwater flow. One of these solutions is the combined heat transfer model of conduction and convection. However, the developed combined analytical models are inapplicable to all of the configurations of ordinary GHEXs because these solutions assume that the inner part of the borehole is thermally inert or consists of the same material as that of the surrounding ground. In this paper, the applicability of the combined solid cylindrical heat source model, which is the most suitable to energy piles until now, was evaluated by performing a series of numerical analyses. In the numerical analysis, the inner part of the borehole was modeled as two different materials (i.e., permeable ground formation and impermeable fill such as concrete to evaluate applicability of the analytical solution along with different diameter-length (D/L ratios of borehole. In a small value of the D/L ratio, the analytical solution to the combined heat transfer model is in good agreement with the result of numerical analysis. On the other hand, when increasing the D/L ratio, the analytical solution significantly overestimates the effect of groundwater flow on the heat transfer of GHEXs because the analytical solution disregards the existence of the impermeable region in the borehole. Consequently, such tendency is more critical in the GHEX with a large D/L ratio such as large-diameter energy piles.

  11. Semi-analytical solutions for flow to a well in an unconfined-fractured aquifer system

    Science.gov (United States)

    Sedghi, Mohammad M.; Samani, Nozar

    2015-09-01

    Semi-analytical solutions of flow to a well in an unconfined single porosity aquifer underlain by a fractured double porosity aquifer, both of infinite radial extent, are obtained. The upper aquifer is pumped at a constant rate from a pumping well of infinitesimal radius. The solutions are obtained via Laplace and Hankel transforms and are then numerically inverted to time domain solutions using the de Hoog et al. algorithm and Gaussian quadrature. The results are presented in the form of dimensionless type curves. The solution takes into account the effects of pumping well partial penetration, water table with instantaneous drainage, leakage with storage in the lower aquifer into the upper aquifer, and storativity and hydraulic conductivity of both fractures and matrix blocks. Both spheres and slab-shaped matrix blocks are considered. The effects of the underlying fractured aquifer hydraulic parameters on the dimensionless drawdown produced by the pumping well in the overlying unconfined aquifer are examined. The presented solution can be used to estimate hydraulic parameters of the unconfined and the underlying fractured aquifer by type curve matching techniques or with automated optimization algorithms. Errors arising from ignoring the underlying fractured aquifer in the drawdown distribution in the unconfined aquifer are also investigated.

  12. Thermal Contrast Amplification Reader Yielding 8-Fold Analytical Improvement for Disease Detection with Lateral Flow Assays.

    Science.gov (United States)

    Wang, Yiru; Qin, Zhenpeng; Boulware, David R; Pritt, Bobbi S; Sloan, Lynne M; González, Iveth J; Bell, David; Rees-Channer, Roxanne R; Chiodini, Peter; Chan, Warren C W; Bischof, John C

    2016-12-06

    There is an increasing need for highly sensitive and quantitative diagnostics at the point-of-care. The lateral flow immunoassay (LFA) is one of the most widely used point-of-care diagnostic tests; however, LFAs generally suffer from low sensitivity and lack of quantification. To overcome these limitations, thermal contrast amplification (TCA) is a new method that is based on the laser excitation of gold nanoparticles (GNPs), the most commonly used visual signature, to evoke a thermal signature. To facilitate the clinical translation of the TCA technology, we present the development of a TCA reader, a platform technology that significantly improves the limit of detection and provides quantification of disease antigens in LFAs. This TCA reader provides enhanced sensitivity over visual detection by the human eye or by a colorimetric reader (e.g., BD Veritor System Reader). More specifically, the TCA reader demonstrated up to an 8-fold enhanced analytical sensitivity and quantification among LFAs for influenza, malaria, and Clostridium difficile. Systematic characterization of the laser, infrared camera, and other components of the reader and their integration into a working reader instrument are described. The development of the TCA reader enables simple, highly sensitive quantification of LFAs at the point-of-care.

  13. Analytical solution to the circularity problem in the discounted cash flow valuation framework

    Directory of Open Access Journals (Sweden)

    Felipe Mejía-Peláez

    2011-12-01

    Full Text Available In this paper we propose an analytical solution to the circularity problem between value and cost of capital. Our solution is derived starting from a central principle of finance that relates value today to value, cash flow, and the discount rate for next period. We present a general formulation without circularity for the equity value (E, cost of levered equity (Ke, levered firm value (V, and the weighted average cost of capital (WACC. We furthermore compare the results obtained from these formulas with the results of the application of the Adjusted Present Value approach (no circularity and the iterative solution of circularity based upon the iteration feature of a spreadsheet, concluding that all methods yield exactly the same answer. The advantage of this solution is that it avoids problems such as using manual methods (i.e., the popular “Rolling WACC” ignoring the circularity issue, setting a target leverage (usually constant with the inconsistencies that result from it, the wrong use of book values, or attributing the discrepancies in values to rounding errors.

  14. Analytical and Experimental Investigation of Flow Through a Turbine Vane Cascade .

    Directory of Open Access Journals (Sweden)

    T. Venkatakrishnaiah

    1993-01-01

    Full Text Available Present day military aero-gas turbines demand higher stage loadings for turbines so as to meet the growing for higher thrust/power with fuel consumption. This calls for improved methods of blade element profiles. Details of a computer code developed for the design of blade elements for the prescribed distribution of surface velocity (Mach number based on Stanitz's inverse methods are presented in this paper. Effects of boundary layer growth on the blade surface has also been incorporated in this code. Turbine vane was designed making use of this program and a four-bladed cascade was fabricated. It was tested in a blow down wind tunnel for different blowing pressures and stagger angles. Mach number distribution was determined from measured static pressure on the suction and pressure surfaces of the blade. Based on stream filament technique a computer code was developed to predict the characteristics of flow thorough a blade cascade. Results of this study show reasonable agreement between experimentally obtained Mach number distribution and the initially prescribed as well as analytically predicted Mach number distributions.

  15. Structure, composition, and strength of nitrifying membrane-aerated biofilms

    DEFF Research Database (Denmark)

    Pellicer i Nàcher, Carles; Smets, Barth F.

    2014-01-01

    Membrane-aerated biofilm reactors (MABRs) are a novel technology based on the growth of biofilms on oxygen-permeable membranes. Hereby, MABRs combine all the advantages of biofilm growth with a more flexible and efficient control of the oxygen load. In the present work, flow cell operation...... had a higher content of proteins and a lower level of carbohydrates. Staining analyses revealed that the EPS in the stronger biofilm regions had hydrophilic nature and distributed around dense microbial aggregates, whereas it was homogeneously distributed in the weaker strata. Overall, the obtained...

  16. Experimental Observation and Analytical Modeling of Melting and Solidification during Aluminum Alloy Repair by Turbulence Flow Casting

    Directory of Open Access Journals (Sweden)

    Muki Satya Permana

    2015-10-01

    Full Text Available This paper presents an overview on the state of the art of applicable casting technology for applications in the field of repairing aluminum alloy components. Repair process on the Al alloy sample using similar metal has been carried out to investigate the micro-structural effect. Joining occurs as a result of convection heat transfer of molten flow into the sand mold which melts the existing base metal inside the mold and subsequent solidification. The analytical model has been developed to describe aluminum alloy component repair by turbulence flow casting. The model is designed based on heat transfer principle that can handle the phenomena of heat flow. The experimental result and analytical model analyses pointed out that joint quality are greatly affected by parameters of preheating temperature and duration of molten metal flow in the mold. To obtain a desired metallurgical sound at the joint, the optimum temperature and time were adjusted in order to obtain a similarity of microstructure between filler and base metal. This model is aimed to predict the use of the process parameter ranges in order to have the optimum parameters when it is applied to the experiment. The fixed parameters are flow rate, sand ratio, and pouring temperature. The process parameters are preheating temperature and pouring time. It is concluded that analytical modeling has good agreement with the experimental result.

  17. On the gravitational signature of zonal flows in Jupiter-like planets: An analytical solution and its numerical validation

    Science.gov (United States)

    Kong, Dali; Zhang, Keke; Schubert, Gerald

    2017-02-01

    It is expected that the Juno spacecraft will provide an accurate spectrum of the Jovian zonal gravitational coefficients that would be affected by both the deep zonal flow, if it exists, and the basic rotational distortion. We derive the first analytical solution, under the spheroidal-shape approximation, for the density anomaly induced by an internal zonal flow in rapidly rotating Jupiter-like planets. We compare the density anomaly of the analytical solution to that obtained from a fully numerical solution based on a three-dimensional finite element method; the two show excellent agreement. We apply the analytical solution to a rapidly rotating Jupiter-like planet and show that there exists a close relationship between the spatial structure of the zonal flow and the spectrum of zonal gravitational coefficients. We check the accuracy of the spheroidal-shape approximation by computing both the spheroidal and non-spheroidal solutions with exactly the same physical parameters. We also discuss implications of the new analytical solution for interpreting the future high-precision gravitational measurements of the Juno spacecraft.

  18. Suitable image parameters and analytical method for quantitatively measuring cerebral blood flow volume with phase-contrast magnetic resonance imaging.

    Directory of Open Access Journals (Sweden)

    Handa H

    1999-02-01

    Full Text Available The aim of this study was to determine suitable image parameters and an analytical method for phase-contrast magnetic resonance imaging (PC-MRI as a means of measuring cerebral blood flow volume. This was done by constructing an experimental model and applying the results to a clinical application. The experimental model was constructed from the aorta of a bull and circulating isotonic saline. The image parameters of PC-MRI (repetition time, flip angle, matrix, velocity rate encoding, and the use of square pixels were studied with percent flow volume (the ratio of actual flow volume to measured flow volume. The most suitable image parameters for accurate blood flow measurement were as follows: repetition time, 50 msec; flip angle, 20 degrees; and a 512 x 256 matrix without square pixels. Furthermore, velocity rate encoding should be set ranging from the maximum flow velocity in the vessel to five times this value. The correction in measuring blood flow was done with the intensity of the region of interest established in the background. With these parameters for PC-MRI, percent flow volume was greater than 90%. Using the image parameters for PC-MRI and the analytical method described above, we evaluated cerebral blood flow volume in 12 patients with occlusive disease of the major cervical arteries. The results were compared with conventional xenon computed tomography. The values found with both methods showed good correlation. Thus, we concluded that PC-MRI was a noninvasive method for evaluating cerebral blood flow in patients with occlusive disease of the major cervical arteries.

  19. Intensified organics and nitrogen removal in the intermittent-aerated constructed wetland using a novel sludge-ceramsite as substrate.

    Science.gov (United States)

    Wu, Haiming; Fan, Jinlin; Zhang, Jian; Ngo, Huu Hao; Guo, Wenshan; Liang, Shuang; Lv, Jialong; Lu, Shaoyong; Wu, Weizhong; Wu, Suqing

    2016-06-01

    In this study, a novel sludge-ceramsite was applied as main substrate in intermittent-aerated subsurface flow constructed wetlands (SSF CWs) for treating decentralized domestic wastewater, and intensified organics and nitrogen removal in different SSF CWs (with and without intermittent aeration, with and without sludge-ceramsite substrate) were evaluated. High removal of 97.2% COD, 98.9% NH4(+)-N and 85.8% TN were obtained simultaneously in the intermittent-aerated CW system using sludge-ceramsite substrate compared with non-aerated CWs. Moreover, results from fluorescence in situ hybridization (FISH) analysis revealed that the growth of ammonia-oxidizing bacteria (AOB) and nitrite-oxidizing bacteria (NOB) in the intermittent-aerated CW system with sludge-ceramsite substrate was enhanced, thus indicating that the application of intermittent aeration and sludge-ceramsite plays an important role in nitrogen transformations. These results suggest that a combination of intermittent aeration and sludge-ceramsite substrate is reliable to enhance the treatment performance in SSF CWs.

  20. EdiFlow: data-intensive interactive workflows for visual analytics

    OpenAIRE

    Benzaken, Veronique; Fekete, Jean-Daniel; Hémery, Pierre-Luc; Khemiri, Wael; Manolescu, Ioana

    2011-01-01

    International audience; Visual analytics aims at combining interactive data visualization with data analysis tasks. Given the explosion in volume and complexity of scientific data, e.g., associated to biological or physical processes or social networks, visual analytics is called to play an important role in scientific data management. Most visual analytics platforms, however, are memory-based, and are therefore limited in the volume of data handled. Moreover, the integration of each new algo...

  1. Analytical solutions for solute transport in groundwater and riverine flow using Green's Function Method and pertinent coordinate transformation method

    Science.gov (United States)

    Sanskrityayn, Abhishek; Suk, Heejun; Kumar, Naveen

    2017-04-01

    In this study, analytical solutions of one-dimensional pollutant transport originating from instantaneous and continuous point sources were developed in groundwater and riverine flow using both Green's Function Method (GFM) and pertinent coordinate transformation method. Dispersion coefficient and flow velocity are considered spatially and temporally dependent. The spatial dependence of the velocity is linear, non-homogeneous and that of dispersion coefficient is square of that of velocity, while the temporal dependence is considered linear, exponentially and asymptotically decelerating and accelerating. Our proposed analytical solutions are derived for three different situations depending on variations of dispersion coefficient and velocity, respectively which can represent real physical processes occurring in groundwater and riverine systems. First case refers to steady solute transport situation in steady flow in which dispersion coefficient and velocity are only spatially dependent. The second case represents transient solute transport in steady flow in which dispersion coefficient is spatially and temporally dependent while the velocity is spatially dependent. Finally, the third case indicates transient solute transport in unsteady flow in which both dispersion coefficient and velocity are spatially and temporally dependent. The present paper demonstrates the concentration distribution behavior from a point source in realistically occurring flow domains of hydrological systems including groundwater and riverine water in which the dispersivity of pollutant's mass is affected by heterogeneity of the medium as well as by other factors like velocity fluctuations, while velocity is influenced by water table slope and recharge rate. Such capabilities give the proposed method's superiority about application of various hydrological problems to be solved over other previously existing analytical solutions. Especially, to author's knowledge, any other solution doesn

  2. Soil Aeration deficiencies in urban sites

    Science.gov (United States)

    Weltecke, Katharina; Gaertig, Thorsten

    2010-05-01

    Soil aeration deficiencies in urban sites Katharina Weltecke and Thorsten Gaertig On urban tree sites reduction of soil aeration by compaction or sealing is an important but frequently underestimated factor for tree growth. Up to 50% of the CO2 assimilated during the vegetation period is respired in the root space (Qi et al. 1994). An adequate supply of the soil with oxygen and a proper disposal of the exhaled carbon dioxide are essential for an undisturbed root respiration. If the soil surface is smeared, compacted or sealed, soil aeration is interrupted. Several references show that root activity and fine root growth are controlled by the carbon dioxide concentration in soil air (Qi et al.1994, Burton et al. 1997). Gaertig (2001) found that decreasing topsoil gas permeability leads to reduced fine root density and hence to injury in crown structure of oaks. In forest soils a critical CO2 concentration of more than 0.6 % indicates a bad aeration status (Gaertig 2001). The majority of urban tree sites are compacted or sealed. The reduction of soil aeration may lead to dysfunctions in the root space and consequently to stress during periods of drought, which has its visible affects in crown structure. It is reasonable to assume that disturbances in soil aeration lead to reduced tree vigour and roadworthiness, resulting in high maintenance costs. The assessment of soil aeration in urban sites is difficult. In natural ecosystems the measurement of gas diffusivity and the gas-chromatical analysis of CO2 in soil air are accepted procedures in analyzing the state of aeration (Schack-Kirchner et al. 2001, Gaertig 2001). It has been found that these methods can also be applied for analyzing urban sites. In particular CO2 concentration in the soil atmosphere can be considered as a rapidly assessable, relevant and integrating indicator of the aeration situation of urban soils. This study tested the working hypothesis that soil aeration deficiencies lead to a decrease of fine

  3. Raising and controlling study of dissolved oxygen concentration in closed-type aeration tank.

    Science.gov (United States)

    Chen, C K; Lo, S L

    2005-07-01

    This study investigated the promotion and control of dissolved oxygen (DO) concentration of the closed-type aeration tank via practical experiments in the wastewater treatment system of a 5-star hotel in Taipei. As with limited and treasured space in Taiwan, before the completion of the sewer system construction in cities, to utilize the mat foundation under large buildings as the space of sewage treatment plant still has been one of the alternatives of those sewage treatments. However, aeration tanks constructed in the mat foundation of buildings have smaller effective water depth, which will cause a lower total transfer amount of DO. Controlling the total exhaust gas flow rate can increase the pressure on such closed-type aeration tanks. The DO concentration thus may increase according to Henry's Law. Furthermore, it may enable operators to adjust the DO concentration of the aeration tank more precisely and thus sustain optimal operating conditions in these treatment facilities. Practical experiments indicated that the DO concentration of aeration tank maintains an average of 3.8 mg l(-1), obtaining the optimum operating conditions. The efficiency of the biological treatment facilities in the mat foundation could be markedly improved.

  4. Towards integrated operation of membrane bioreactors: effects of aeration on biological and filtration performance.

    Science.gov (United States)

    Dalmau, M; Monclús, H; Gabarrón, S; Rodriguez-Roda, I; Comas, J

    2014-11-01

    Two experimental studies evaluated the effect of aerobic and membrane aeration changes on sludge properties, biological nutrient removal and filtration processes in a pilot plant membrane bioreactor. The optimal operating conditions were found at an aerobic dissolved oxygen set-point (DO) of 0.5 mg O2 L(-1) and a membrane specific aeration demand (SADm) of 1 m h(-1), where membrane aeration can be used for nitrification. Under these conditions, a total flow reduction of 42% was achieved (75% energy reduction) without compromising nutrient removal efficiencies, maintaining sludge characteristics and controlled filtration. Below these optimal operating conditions, the nutrient removal efficiency was reduced, increasing 20% for soluble microbial products, 14% for capillarity suction time and reducing a 15% for filterability. Below this DO set-point, fouling increased with a transmembrane pressure 75% higher. SADm below 1 m h(-1) doubled the values of transmembrane pressure, without recovery after achieving the initial conditions.

  5. Analytical solutions of three-dimensional groundwater flow to a well in a leaky sloping fault-zone aquifer

    Science.gov (United States)

    Zhao, Yuqing; Zhang, You-Kuan; Liang, Xiuyu

    2016-08-01

    A semi-analytical solution was presented for groundwater flow due to pumping in a leaky sloping fault-zone aquifer surrounded by permeable matrices. The flow in the aquifer was descried by a three-dimensional flow equation, and the flow in the upper and lower matrix blocks are described by a one-dimensional flow equation. A first-order free-water surface equation at the outcrop of the fault-zone aquifer was used to describe the water table condition. The Laplace domain solution was derived using Laplace transform and finite Fourier transform techniques and the semi-analytical solutions in the real time domain were evaluated using the numerical inverse Laplace transform method. The solution was in excellent agreement with Theis solution combined with superposition principle as well as the solution of Huang et al. (2014). It was found that the drawdown increases as the sloping angle of the aquifer increases in early time and the impact of the angle is insignificant after pumping for a long time. The free-water surface boundary as additional source recharges the fault aquifer and significantly affect the drawdown at later time. The surrounding permeable matrices have a strong influence on drawdown but this influence can be neglected when the ratio of the specific storage and the ratio of the hydraulic conductivity of the matrices to those of the fault aquifer are less than 0.001.

  6. PRESSURE CHARACTERISTICS OF CAVITATION CONTROL BY AERATION

    Institute of Scientific and Technical Information of China (English)

    DONG Zhi-yong; LU Yang-quan; JU Wen-jie; CAI Xin-ming; DING Chun-sheng

    2005-01-01

    This experimental investigation was systematically conducted with the aid of a non-circulating water tunnel in the Hydraulics Laboratory at Zhejiang University of Technology in China.The test velocity is between 20m/s and 40m/s.The least air concentration to prevent cavitation erosion lies between 1.7% and 4.5%.Pressure waveforms with and without aeration in cavitation and cavitation erosion regions were measured.Time-averaged pressure profiles with and without aeration were compared.Pressure characteristics corresponding to least air concentration to prevent cavitation erosion in cavitation and cavitation erosion regions were analyzed.

  7. Shear reinforced beams in autoclaved aerated concrete

    DEFF Research Database (Denmark)

    Cornelius, Thomas

    2010-01-01

    Shear behaviour in concrete materials is very well documented, for normal density concrete materials. In this paper results of various tests on low density concrete materials like aerated autoclaved concrete (in the following denoted aircrete) will be presented and analyzed for different combinat......Shear behaviour in concrete materials is very well documented, for normal density concrete materials. In this paper results of various tests on low density concrete materials like aerated autoclaved concrete (in the following denoted aircrete) will be presented and analyzed for different...

  8. A simple analytical method to estimate all exit parameters of a cross-flow air dehumidifier using liquid desiccant.

    Science.gov (United States)

    Bassuoni, M M

    2014-03-01

    The dehumidifier is a key component in liquid desiccant air-conditioning systems. Analytical solutions have more advantages than numerical solutions in studying the dehumidifier performance parameters. This paper presents the performance results of exit parameters from an analytical model of an adiabatic cross-flow liquid desiccant air dehumidifier. Calcium chloride is used as desiccant material in this investigation. A program performing the analytical solution is developed using the engineering equation solver software. Good accuracy has been found between analytical solution and reliable experimental results with a maximum deviation of +6.63% and -5.65% in the moisture removal rate. The method developed here can be used in the quick prediction of the dehumidifier performance. The exit parameters from the dehumidifier are evaluated under the effects of variables such as air temperature and humidity, desiccant temperature and concentration, and air to desiccant flow rates. The results show that hot humid air and desiccant concentration have the greatest impact on the performance of the dehumidifier. The moisture removal rate is decreased with increasing both air inlet temperature and desiccant temperature while increases with increasing air to solution mass ratio, inlet desiccant concentration, and inlet air humidity ratio.

  9. Analytic Approximate Solutions to the Boundary Layer Flow Equation over a Stretching Wall with Partial Slip at the Boundary.

    Science.gov (United States)

    Ene, Remus-Daniel; Marinca, Vasile; Marinca, Bogdan

    2016-01-01

    Analytic approximate solutions using Optimal Homotopy Perturbation Method (OHPM) are given for steady boundary layer flow over a nonlinearly stretching wall in presence of partial slip at the boundary. The governing equations are reduced to nonlinear ordinary differential equation by means of similarity transformations. Some examples are considered and the effects of different parameters are shown. OHPM is a very efficient procedure, ensuring a very rapid convergence of the solutions after only two iterations.

  10. Analytic solution to the micropolar-fluid flow through a semi-porous channel with an expanding or contracting wall

    Institute of Scientific and Technical Information of China (English)

    Xin-hui SI; Lian-cun ZHENG; Xin-xin ZHANG; Ying CHAO

    2010-01-01

    The flow of a micropolar fluid in a semi-porous channel with an expanding or contracting wall is investigated.The governing equations are reduced to ordinary ones by using similar transformations.To get the analytic solution to the problem,the homotopy analysis method(HAM)is employed to obtain the expressions for velocity fields.Graphs are sketched and discussed for various parameters,especially the effect of the expansion ratio on velocity and micro-rotation fields.

  11. Analytical and experimental characterization of a miniature calorimetric sensor in a pulsatile flow

    NARCIS (Netherlands)

    Gelderblom, H.; Horst, van der A.; Haartsen, J.R.; Rutten, M.C.M.; Ven, van de A.A.F.; Vosse, van de F.N.

    2010-01-01

    The behaviour of a miniature calorimetric sensor, which is under consideration for catheter-based coronary-artery-flow assessment, is investigated in both steady and pulsatile tube flows. The sensor is composed of a heating element operated at constant power and two thermopiles that measure flow-ind

  12. An efficient analytical decomposition and numerical procedure for boundary layer flow on a continuous stretching surface

    Institute of Scientific and Technical Information of China (English)

    Xuehui Chen; Liancun Zheng; Xinxin Zhang

    2006-01-01

    An efficient Adomian analytical decomposition technique for studying the momentum and heat boundary layer equations with exponentially stretching surface conditions was presented and an approximate analytical solution was obtained, which can be represented in terms of a rapid convergent power series with elegantly computable terms. The reliability and efficiency of the approximate solution were verified using numerical solutions in the literature. The approximate solution can be successfully applied to provide the values of skin friction and the temperature gradient coefficient.

  13. Estimation of volume flow in curved tubes based on analytical and computational analysis of axial velocity profiles

    Science.gov (United States)

    Verkaik, A. C.; Beulen, B. W. A. M. M.; Bogaerds, A. C. B.; Rutten, M. C. M.; van de Vosse, F. N.

    2009-02-01

    To monitor biomechanical parameters related to cardiovascular disease, it is necessary to perform correct volume flow estimations of blood flow in arteries based on local blood velocity measurements. In clinical practice, estimates of flow are currently made using a straight-tube assumption, which may lead to inaccuracies since most arteries are curved. Therefore, this study will focus on the effect of curvature on the axial velocity profile for flow in a curved tube in order to find a new volume flow estimation method. The study is restricted to steady flow, enabling the use of analytical methods. First, analytical approximation methods for steady flow in curved tubes at low Dean numbers (Dn) and low curvature ratios (δ) are investigated. From the results a novel volume flow estimation method, the cos θ-method, is derived. Simulations for curved tube flow in the physiological range (1≤Dn≤1000 and 0.01≤δ≤0.16) are performed with a computational fluid dynamics (CFD) model. The asymmetric axial velocity profiles of the analytical approximation methods are compared with the velocity profiles of the CFD model. Next, the cos θ-method is validated and compared with the currently used Poiseuille method by using the CFD results as input. Comparison of the axial velocity profiles of the CFD model with the approximations derived by Topakoglu [J. Math. Mech. 16, 1321 (1967)] and Siggers and Waters [Phys. Fluids 17, 077102 (2005)] shows that the derived velocity profiles agree very well for Dn≤50 and are fair for 50100), no analytical approximation method exists. In the position of the maximum axial velocity, a shift toward the inside of the curve is observed for low Dean numbers, while for high Dean numbers, the position of the maximum velocity is located at the outer curve. When the position of the maximum velocity of the axial velocity profile is given as a function of the Reynolds number, a "zero-shift point" is found at Re=21.3. At this point the shift in

  14. TENSIC- a two-phase - flow / multimigrant transport model for simulation reaction- and transport- processes in the aeration zone of mine dumps; Beschreibung der Reaktions- und Transportvorgaenge in Halden durch das Mehrmigrantenstofftransport-Zweiphasenstroemungsmodell TENSIC

    Energy Technology Data Exchange (ETDEWEB)

    Eckart, M.; Mocker, D.; Pollmer, K. [GEOCONTROL GmbH, Gera (Germany); Jahn, S. [WISMUT GmbH (Germany)

    1998-12-31

    The model TENSIC was developed to characterize reaction- and transport-processes in the zone of aeration of mine dumps. It enables us to illustrate the space-time development of pressure, saturation and concentration in a porous media, taking into account real day to day climatic data. As initial data for the model-calculation only the solid-concentrations of the dump-material are required. The model is calibrated for the specific dumps by calculating the actual seepage water concentrations starting from the beginning of the dump material deposition. Using TENSIC a continuous modelling from the beginning of the deposition through a 25-45 year period (mean age of dumps) of uncovered exposure to atmospheric conditions up to a 100 to 500 year period in the future of the covered mine dump was carried out. For different dump covering materials the pollutant concentration- and load development was simulated. TENSIC is used for instance to investigate the Reust, Drosen, Beerwalde, Nordhalde, Paitzdorf and Schlema-Alberoda dumps. The modelling of the Paitzdorf dump is described. (orig.)

  15. Package plant of extended aeration membrane bioreactors: a study on aeration intensity and biofouling control.

    Science.gov (United States)

    Ujang, Z; Ng, S S; Nagaoka, H

    2005-01-01

    Biofouling control is important for effective process of membrane bioreactor (MBR). In this study, phenomena of biofouling for immersed type extended aeration MBR with two different anti-fouling aeration intensities were studied through a laboratory set up. The objectives of this study were (a) to observe biofouling phenomena of MBR that operates under different anti-fouling bubbling intensity, and simultaneously monitors performance of the MBR in organic carbon and nutrients removal; (b) to compare effectiveness of detergent and detergent-enzyme cleaning solutions in recovering biofouled membranes that operated in the extended aeration MBR. For MBR, which operated under continuous anti-fouling aeration, deposition and accumulation of suspended biomass on membrane surface were prohibited. However, flux loss was inescapable that biofilm layer was the main problem. Membrane cleaning was successfully carried out with detergent-enzyme mixture solutions and its effectiveness was compared with result from cleaning with just detergent solution.

  16. Soil Aeration Variability as Affected by Reoxidation

    Institute of Scientific and Technical Information of China (English)

    A.WOLI(N)SKA; Z.ST(E)PNIEWSKA

    2013-01-01

    The interplay between soil physical parameters during the recovery from anoxic stresses (reoxidation) is largely unrecognized.This study was conducted to characterise the soil aeration status and derive correlations between variable aeration factors during reoxidation.Surface layers (0-30 cm) of three soil types,Haplic Phaeozem,Mollic Gleysol,and Eutric Cambisol (FAO soil group),were selected for analysis.The moisture content was determined for a range of pF values (0,1.5,2.2,2.7,and 3.2),corresponding to the available water for microorganisms and plant roots.The variability of a number of soil aeration parameters,such as water potential (pF),air-filled porosity (Eg),oxygen diffusion rate (ODR),and redox potential (Eh),were investigated.These parameters were found to be interrelated in most cases.There were significant (P < 0.001) negative correlations of pF,Eg,and ODR with Eh.A decrease in water content as a consequence of soil reoxidation was manifested by an increase in the values of aeration factors in the soil environment.These results contributed to understanding of soil redox processes during recovery from flooding and might be useful for development of agricultural techniques aiming at soil reoxidation and soil fertility optimisation.

  17. AN ANALYTIC APPROACH TO THEORETICAL MODELING OF HIGHLY UNSTEADY VISCOUS FLOW EXCITED BY WING FLAPPING IN SMALL INSECTS

    Institute of Scientific and Technical Information of China (English)

    余永亮; 童秉纲; 马晖扬

    2003-01-01

    Numerous studies on the aerodynamics of insect wing flapping were carried out on different approaches of flight investigations, model experiments, and numerical simulations, but the theoretical modeling remains to be explored. In the present paper, an analytic approach is presented to model the flow interactions of wing flapping in air for small insects with the surrounding flow fields being highly unsteady and highly viscous. The model of wing flapping is a 2-D flat plate, which makes plunging and pitching oscillations as well as quick rotations reversing its positions of leading and trailing edges, respectively, during stroke reversals. It contains three simplified aerodynamic assumptions:(i) unsteady potential flow; (ii) discrete vortices shed from both leading and trailing edges of the wing; (iii) Kutta conditions applied at both edges. Then the problem is reduced to the solution of the unsteady Laplace equation, by using distributed singularities, i.e., sources/sinks, and vortices in the field. To validate the present physical model and analytic method proposed via benchmark examples, two elemental motions in wing flapping and a case of whole flapping cycles are analyzed,and the predicted results agree well with available experimental and numerical data. This verifies that the present analytical approach may give qualitatively correct and quantitatively reasonable results.Furthermore, the total fluid-dynamic force in the present method can be decomposed into three parts:one due to the added inertial (or mass) effect, the other and the third due to the induction of vortices shed from the leading- and the trailing-edge and their images respectively, and this helps to reveal the flow control mechanisms in insect wing flapping.

  18. Relationship between ecosystem respiration and aeration constant in open channel dissolved oxygen analysis

    Science.gov (United States)

    Parker, S. J.; Butler, A. P.; Heppell, C. M.

    2015-12-01

    Using the open channel diel method of Odum (1956) and the night-time regression method (Hornberger and Kelly, 1985), we analysed a time series of dissolved oxygen (DO) in two slow flowing streams for a two month period in summer 2014 and obtained values for ecosystem respiration and the aeration constant for each day in the period. We then used the standard dissolved oxygen lumped model to generate a DO time series behaviour for one of those rivers selecting respiration and aeration parameters by randomly sampling from the values obtained from the data. Two synthetic time series were created, one where respiration and aeration were independent of temperature and a second where respiration and aeration were affected by temperature according to the modified Arrhenius relationship. With these two synthetic time series, we again recovered the respiration and aeration input parameters using the night- time regression method and compared those recovered parameters with the input parameters. Because the simulations were conducted with parameters that were known, the values recovered using the night-time regression method (i.e post-simulation) could be compared with parameters driving the simulation (i.e. pre-simulation input values). For values based on data, we found a strong correlation between the aeration constant and respiration for both rivers. For the synthetic time series, no such correlation was found, either with the temperature independent or temperature dependent time series. The night-time regression method also recovered perfectly the input parameters, so the correlation was not brought about as a result of implementing the method itself. We are currently investigating the cause of the correlation.

  19. Analytical study of two-phase-flow heat exchangers for OTEC Systems

    Energy Technology Data Exchange (ETDEWEB)

    Olsen, H.L.; Pandolfini, P.P.

    1975-07-01

    The work began in July 1975. Prior in-house research at the Laboratory had spanned two years and had yielded a preliminary design for a low-cost OTEC plant--ship intended for operation in tropical oceans for producing ammonia or other energy-intensive products. Because the heat exchanger concept represented an extrapolation from existing experience, a comprehensive analytical study followed by an essentially full-scale experiment with the basic heat exchanger elements is needed. The analytical study reported herein is believed to meet the first requirement, and a plan for the experiment is included. (WDM)

  20. Analytical and experimental characterization of a miniature calorimetric sensor in a pulsatile flow

    NARCIS (Netherlands)

    Gelderblom, Hanneke; van der Horst, A.; Haartsen, J.R.; Rutten, M.C.M.; van de Ven, A.A.F.; van de Vosse, F.N.

    2010-01-01

    The behaviour of a miniature calorimetric sensor, which is under consideration for catheter-based coronary-artery-flow assessment, is investigated in both steady and pulsatile tube flows. The sensor is composed of a heating element operated at constant power and two thermopiles that measure

  1. Analytical and experimental studies of flow-induced vibration of SSME components

    Science.gov (United States)

    Chen, S. S.; Jendrzejczyk, J. A.; Wambsganss, M. W.

    1987-01-01

    Components of the Space Shuttle Main Engines (SSMEs) are subjected to a severe environment that includes high-temperature, high-velocity flows. Such flows represent a source of energy that can induce and sustain large-amplitude vibratory stresses and/or result in fluidelastic instabilities. Three components are already known to have experienced failures in evaluation tests as a result of flow-induced structural motion. These components include the liquid-oxygen (LOX) posts, the fuel turbine bellows shield, and the internal inlet tee splitter vane. Researchers considered the dynamic behavior of each of these components with varying degrees of effort: (1) a theoretical and experimental study of LOX post vibration excited by a fluid flow; (2) an assessment of the internal inlet tee splitter vane vibration (referred to as the 4000-Hz vibration problem); and (3) a preliminary consideration of the bellows shield problem. Efforts to resolve flow-induced vibration problems associated with the SSMEs are summarized.

  2. Susceptibility assessment of debris flows using the analytic hierarchy process method-A case study in Subao river valley, China

    Institute of Scientific and Technical Information of China (English)

    Xingzhang Chen; Hui Chen; Yong You; Jinfeng Liu

    2015-01-01

    Many debris flows have occurred in the areas surrounding the epicenter of the Wenchuan earthquake. Susceptibility assessment of debris flows in this area is especially important for disaster prevention and mitigation. This paper studies one of the worst hit areas, the Subao river valley, and the susceptibility assessment of debris flows is performed based on field surveys and remote sensing interpretation. By investigating the formation conditions of debris flows in the valley, the following assessment factors are selected: mixture density of landslides and rock avalanches, distance to the seismogenic fault, stratum lithology, ground roughness, and hillside angle. The weights of the assessment factors are determined by the analytic hierarchy process (AHP) method. Each of the assessment factors is further divided into five grades. Then, the assessment model is built using the multifactor superposition method to assess the debris flow susceptibility. Based on the assessment results, the Subao river valley is divided into three areas: high susceptibility areas, medium susceptibility areas, and low susceptibility areas. The high susceptibility areas are concentrated in the middle of the valley, accounting for 17.6%of the valley area. The medium susceptibility areas are in the middle and lower reaches, most of which are located on both sides of the high susceptibility areas and account for 45.3% of the valley area. The remainders are clas-sified as low susceptibility areas. The results of the model are in accordance with the actual debris flow events that occurred after the earthquake in the valley, confirming that the proposed model is capable of assessing the debris flow susceptibility. The results can also provide guidance for reconstruction planning and debris flow prevention in the Subao river valley.

  3. Analytic model of a two wire thermal sensor for flow and sound measurements

    NARCIS (Netherlands)

    Honschoten, van J.W.; Krijnen, G.J.M.; Svetovoy, V.B.; Bree, de H.E.; Elwenspoek, M.C.

    2004-01-01

    The Microflown is an acoustic sensor that measures particle velocity instead of pressure, as conventional microphones do. This paper presents an analytical model describing the physical processes that govern the behaviour of the sensor and determine its sensitivity. Forced convection by an acoustic

  4. An Analytical Study on Boundary Layer Flow and Heat Transfer of Nanofluid Induced by a Non-Linearly Stretching Sheet

    Directory of Open Access Journals (Sweden)

    A. Malvandi

    2014-01-01

    Full Text Available Steady two-dimensional boundary layer flow of a nanofluid past a nonlinear stretching sheet is investigated analytically using the Homotopy Analysis Method (HAM. The employed model for nanofluid includes twocomponent four-equation non-homogeneous equilibrium model that incorporates the effects of Brownian motion ( Nb , thermophoresis ( Nt and Lewis number ( Le simultaneously. The basic partial boundary layer equations have been reduced to a two-point boundary value problem via the similarity variables. Analytical results are in best agreements with those existing in the literatures. The outcomes signify the decreasing trend of heat transfer rate with thermophoresis, Brownian motion and Lewis number. However, concentration rate has a sensitive behavior with parameters, especially the Brownian motion and thermophoresis parameters. Also, the weak points of numerical methods in such problems have been mentioned and the efficiency of HAM, as an alternative approach, in solving these kinds of nonlinear coupled problems has been shown.

  5. ANALYTICAL AND EXPERIMENTAL INVESTIGATION OF FLOW DISTRIBUTION IN MANIFOLDS FOR HEAT EXCHANGERS

    Institute of Scientific and Technical Information of China (English)

    LU Fang; LUO Yong-hao; YANG Shi-ming

    2008-01-01

    The prediction of flow distribution in flow manifolds is important for the design of heat exchangers. The pressure drop along the flow in the header is the most influential factor in flow distribution. Various continuous models available in literature have failed to satisfactorily predict the pressure distribution in the headers of the flow manifolds. In this article, a discrete model matching the real physical phenomena has been proposed, to predict the pressure distribution in headers. An experimental evaluation of relevant flow characteristic parameters has been carried out to support the discrete model calculations. The validity of the theoretical discrete model has been performed with experimental results, under specific conditions. Refined experimental probes, for pressure heads with ultrasonic measuring devices, have been used to obtain accurate results. The experimental results fully substantiate the soundness of the theoretical prediction. In addition, the advantage of the ability to accommodate local disturbances in the discrete model has been pointed out. The effect of some local disturbances may be substantial. As a result of the analysis presented in this article, improved designs of flow manifolds in heat exchangers can be realized, to assure operation safety under severe operating conditions.

  6. Effects of analyte velocity modulation on the electroosmotic flow in capillary electrophoresis.

    Science.gov (United States)

    Demana, T; Guhathakurta, U; Morris, M D

    1992-02-15

    Modulation of the electroosmotic flow in capillary zone electrophoresis by modulation of the driving voltage gives rise to a flow profile that changes between laminar and flat profiles. The changing flow profile induces a radial movement of sample species to and from the capillary surface. The induced sample concentration gradient can be monitored by carefully probing the capillary surface. The resulting signal is a derivative of the normal-shaped peak. Derivative-shaped peaks can be observed with cations, but not with anions. Anions are unable to approach the double-layer region and therefore are unaffected by the modulation process.

  7. Steady-state turbulent flow of a conducting liquid in a longitudinal magnetic field with volume heat evolution. I. Analytical study of flow in the inwall region

    Energy Technology Data Exchange (ETDEWEB)

    Bortsaikin, S.M.; Levitan, Yu.S.

    1977-07-01

    An examination is made of steady-state turbulent flow of a conducting liquid in a cylindrical channel in a longitudinal magnetic field. The system of motion equations and energy can be recorded in a convenient integral form by using the Prandtl hypothesis for computing turbulent coefficients with rather simple assumptions about the nature of the velocity gradient. A small parameter in the equations can be easily identified in direct proximity to the channel's wall that makes it possible to find an approximate analytical solution to this problem in this region. 6 references, 1 figure.

  8. Comparison of Different Analytic Solutions to Axisymmetric Squeezing Fluid Flow between Two Infinite Parallel Plates with Slip Boundary Conditions

    Directory of Open Access Journals (Sweden)

    Hamid Khan

    2012-01-01

    Full Text Available We investigate squeezing flow between two large parallel plates by transforming the basic governing equations of the first grade fluid to an ordinary nonlinear differential equation using the stream functions ur(r,z,t=(1/r(∂ψ/∂z and uz(r,z,t=−(1/r(∂ψ/∂r and a transformation ψ(r,z=r2F(z. The velocity profiles are investigated through various analytical techniques like Adomian decomposition method, new iterative method, homotopy perturbation, optimal homotopy asymptotic method, and differential transform method.

  9. An efficient analytical approach for MHD viscous flow over a stretching sheet via homotopy perturbation sumudu transform method

    Directory of Open Access Journals (Sweden)

    Sushila

    2013-09-01

    Full Text Available In this paper, we present an efficient analytical approach based on new homotopy perturbation sumudu transform method (HPSTM to investigate the magnetohydrodynamics (MHD viscous flow due to a stretching sheet. The viscous fluid is electrically conducting in the presence of magnetic field and the induced magnetic field is neglected for small magnetic Reynolds number. Finally, some numerical comparisons among the new HPSTM, the homotopy perturbation method and the exact solution have been made. The numerical solutions obtained by the proposed method show that the approach is easy to implement and computationally very attractive.

  10. Bingham plastic fluid flow model in tape casting of ceramics using two doctor blades – analytical approach

    DEFF Research Database (Denmark)

    Jabbari, Masoud; Hattel, Jesper Henri

    2014-01-01

    , and it is therefore of great interest to be able to control it. One way to control the tape thickness is to use a two doctor blade configuration in the tape casting machine. In this case, it becomes important to fix the height of the slurry in front of both doctor blades according to the desired tape thickness...... and casting speed (belt velocity). In the present work, the flow in both doctor blade regions of a slurry is described with a steady state momentum equation in combination with a Bingham plastic constitutive equation, and this is integrated to a closed form analytical solution for both reservoirs based...

  11. Studies of the analyte-carrier interface in flow injection analysis

    Energy Technology Data Exchange (ETDEWEB)

    Brown, S.D.

    1992-01-01

    Chemical analysis in flowing solution is popular for automation of classical methods. However, most of the classical methods are not specific enough for direct multicomponent analysis of simple mixtures. This research project has the goals of study of rapid multicomponent analysis of transient species in flowing media, and investigations of chemical reactions at interfaces and of effects of competition on distribution of products from interfacial reaction. This report summarizes work done over the past 4.5 years; support has been terminated.

  12. Experimental and Analytic Study on the Core Bypass Flow in a Very High Temperature Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Richard Schultz

    2012-04-01

    Core bypass flow has been one of key issues in the very high temperature reactor (VHTR) design for securing core thermal margins and achieving target temperatures at the core exit. The bypass flow in a prismatic VHTR core occurs through the control element holes and the radial and axial gaps between the graphite blocks for manufacturing and refueling tolerances. These gaps vary with the core life cycles because of the irradiation swelling/shrinkage characteristic of the graphite blocks such as fuel and reflector blocks, which are main components of a core's structure. Thus, the core bypass flow occurs in a complicated multidimensional way. The accurate prediction of this bypass flow and counter-measures to minimize it are thus of major importance in assuring core thermal margins and securing higher core efficiency. Even with this importance, there has not been much effort in quantifying and accurately modeling the effect of the core bypass flow. The main objectives of this project were to generate experimental data for validating the software to be used to calculate the bypass flow in a prismatic VHTR core, validate thermofluid analysis tools and their model improvements, and identify and assess measures for reducing the bypass flow. To achieve these objectives, tasks were defined to (1) design and construct experiments to generate validation data for software analysis tools, (2) determine the experimental conditions and define the measurement requirements and techniques, (3) generate and analyze the experimental data, (4) validate and improve the thermofluid analysis tools, and (5) identify measures to control the bypass flow and assess its performance in the experiment.

  13. Analytical Investigation on 2-D Unsteady MHD Viscoelastic Flow between Moving Parallel Plates Using RVIM and HPM

    Directory of Open Access Journals (Sweden)

    Alireza AZIMI

    2014-07-01

    Full Text Available In this paper the velocity fields associated with the two-dimensional unsteady magnetohydrodynamic (MHD flow of a viscous fluid between moving parallel plates have been investigated. The governing Navier-Stokes equations for the flow are reduced to a fourth order nonlinear ordinary differential equation. The Homotopy Perturbation Method (HPM and Reconstruction of Variational Iteration Method (RVIM have been used to achieve analytical solutions. The obtained approximate results have been compared with numerical ones and results from pervious works in some cases. It has been shown that the current study is accurate and validated and can be used for other nonlinear cases.doi:10.14456/WJST.2014.70

  14. Analytic solution for magnetohydrodynamic boundary layer flow of Casson fluid over a stretching/shrinking sheet with wall mass transfer

    Institute of Scientific and Technical Information of China (English)

    Krishnendu Bhattacharyya; Tasawar Hayat; Ahmed Alsaedi

    2013-01-01

    In this analysis,the magnetohydrodynamic boundary layer flow of Casson fluid over a permeable stretching/shrinking sheet in the presence of wall mass transfer is studied.Using similarity transformations,the governing equations are converted to an ordinary differential equation and then solved analytically.The introduction of a magnetic field changes the behavior of the entire flow dynamics in the shrinking sheet case and also has a major impact in the stretching sheet case.The similarity solution is always unique in the stretching case,and in the shrinking case the solution shows dual nature for certain values of the parameters.For stronger magnetic field,the similarity solution for the shrinking sheet case becomes unique.

  15. Numerical and analytical treatment on peristaltic flow of Williamson fluid in the occurrence of induced magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Akram, Safia, E-mail: safia_akram@yahoomail.com [Department of Basic Sciences, Military College of Signals, National University of Sciences and Technology (Pakistan); Nadeem, S. [Department of Mathematics, Quaid-i-Azam University 45320, Islamabad 44000 (Pakistan); Hanif, M. [Department of Basic Sciences, Military College of Signals, National University of Sciences and Technology (Pakistan)

    2013-11-15

    In this paper the effects of induced magnetic field on the peristaltic transport of a Williamson fluid model in an asymmetric channel has been investigated. The problem is simplified by using long wave length and low Reynolds number approximations. The perturbation and numerical solutions have been presented. The expressions for pressure rise, pressure gradient, stream function, magnetic force function, current density distribution have been computed. The results of pertinent parameters have been discussed graphically. The trapping phenomena for different wave forms have been also discussed. - highlights: • The main motivation of this work is that we want to see the behavior of peristaltic flow of Williamson fluid in the occurrence of induced magnetic field. In literature no attempt is taken to discuss the lateral Numerical and analytical treatment on peristaltic flow of Williamson fluid in the occurrence of induced magnetic field. • We do not want to fill the gap in literature after studying this.

  16. Analytical method for softness abrasive flow field based on discrete phase model

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    Aiming at the problem of difficult contact finishing for mini structural surface in course of mould manufacturing,a new no-tool precision machining method based on soft abrasive flow machining (SAFM) was proposed. It allocated restrained component near surface machined,constituted restrained abrasive flow passage,and made the surface become a segment of passage wall. It could control turbulence abrasive flow in restrained passage,realize micro cutting for passage wall,and utilize the irregular motion of abrasive flow to eliminate the mono-directional marks on machined surfaces,and the precision could reach the specular level. A two-phase dynamic model of abrasive flow oriented to SAFM combined with discrete phase model (DPM) was established,the law of two-phase flow motion and the related physical parameters was obtained by corresponding numerical simulation method,and the mechanism of precision machining in SAFM was discussed. Simulation results show that the abrasive flow machining process mainly appears as translation of ablating location with the influence by granular pressure,and as the variation of machining efficiency with the influence by near-wall particle velocity. Thus via control of the inlet velocity and its corresponding machining time,it is supposed to work out the machining process according to the machining requirements by using the Preston equation to seek the relationship among velocity,pressure and material removing rate. By tracking near-wall particles,it can be confirmed that the movement of near-wall abrasive particles is similar to stream-wise vortices. The cutting traces on workpiece surfaces assume disorderly arrangement,so the feasibility of the SAFM method can be reaffirmed.

  17. Discrete Analytic Domains: a New Technique for Groundwater Flow Modeling in Layered, Anisotropic, and Heterogeneous Aquifer Systems

    Science.gov (United States)

    Fitts, C. R.

    2004-12-01

    A new technique for modeling groundwater flow with analytic solutions is presented. It allows modeling of layered aquifer systems with complex heterogeneity and anisotropy. As with previous AEM techniques, flow in each layer is modeled with two-dimensional analytic solutions, there is high accuracy and resolution, the domain is not discretized into grid blocks or elements, and the modeled area can easily be altered and expanded in the midst of the modeling process. This method differs from previous Analytic Element Method (AEM) techniques by allowing general anisotropy conditions in the aquifer. The flow field is broken into discrete polygonal domains, each with its own definition of isotropic or anisotropic aquifer parameters. An advantage of this approach is that the anisotropy orientation and ratio can differ from one domain to another, a capability not possible with the "infinite domain" of previous AEM formulations. With this approach, the potential and discharge vector functions at a point are the sum of contributions from elements within or on the boundary of the domain containing the point. Unlike previous AEM schemes, elements beyond the domain boundary don't contribute to these functions. Once a solution is in hand, less computation is required to evaluate heads and discharges because fewer elements contribute to the equations. This computational efficiency could prove a significant advantage in large regional models and in solute transport models that use a flow model's velocity field. This technique allows multiple aquifer layers to be stacked vertically, and it has the novel ability to have more layers in the area of interest than in distant areas. This feature can save significant computation and input effort by concentrating layering detail only where it is needed and warranted by data. The boundary conditions at line element boundaries are approximated, including the continuity of flow and head across heterogeneity boundaries. By using high

  18. Study of the opportunities of analytical determination of the origin-destination flows in roundabout intersections based on data provided by fixed observers

    Science.gov (United States)

    Neagu, E.; Boroiu, A. A.; Rizea, V.; Boroiu, A.

    2016-08-01

    For the purposes of the analysis of road traffic at the level of the area surrounding a roundabout intersection there are times when the flows of Origin-Destination (O-D flows) of the respective intersection are of interest - when it is not possible to improve the level of service of the intersection by means of increasing its capacity, but only by diverting some traffic flows from the respective area. Currently, the determining of these O-D flows is based on video recordings of the intersection traffic, followed by laborious and lengthy analyses of the images obtained. But a prolific way, yet not explored in specialised literature, can be the identification of the analytic relations between O-D flow volumes and the volumes of the intersection traffic flows that can be measured by fixed observers (incoming flows, outgoing flows and conflict flows). As a result, this paper presents the research conducted to identify the possible relationships between these deterministic O-D flows and the flows that can be measured by fixed observers. It was demonstrated that, when performing measuring of the flow of vehicles that turn right with fixed observers, there will be analytical deterministic relationships for the 3-armed intersection with return flows, as well as for the 4-armed intersection without return flows. This means that, for 3-armed intersections with return flows and for 4-armed intersections without return flows, it is possible to fully know the O-D flows based on the flows measured by fixed observers (compulsorily involving right-turn flows), which is an absolutely exciting and unique achievement, as knowing these Origin-Destination flows will allow better regulation of the traffic in the area where the roundabout intersection is, in order to facilitate the upstream diversion of some of O-D flows passing through the roundabout intersection.

  19. Modeling rain-driven overland flow: empirical versus analytical friction terms in the shallow water approximation

    CERN Document Server

    Kirstetter, G; Delestre, O; Darboux, F; Lagrée, P -Y; Popinet, S; Fullana, J -M; Josserand, C

    2016-01-01

    Modeling and simulating overland flow fed by rainfall is a common issue in watershed surface hydrology. Modelers have to choose among various friction models when defining their simulation framework. The purpose of this work is to compare the simulation quality for the Manning, Darcy-Weisbach, and Poiseuille friction models on the simple case of a constant rain on a thin experimental flume. Results show that the usual friction law of Manning is not suitable for this type of flow. The Poiseuille friction model gave the best results both on the flux at the outlet and the velocity and depth profile along the flume. The Darcy-Weisbach model shows good results for laminar flow. Additional testing should be carried out for turbulent cases.

  20. Modelling turbulent boundary layer flow over fractal-like multiscale terrain using large-eddy simulations and analytical tools.

    Science.gov (United States)

    Yang, X I A; Meneveau, C

    2017-04-13

    In recent years, there has been growing interest in large-eddy simulation (LES) modelling of atmospheric boundary layers interacting with arrays of wind turbines on complex terrain. However, such terrain typically contains geometric features and roughness elements reaching down to small scales that typically cannot be resolved numerically. Thus subgrid-scale models for the unresolved features of the bottom roughness are needed for LES. Such knowledge is also required to model the effects of the ground surface 'underneath' a wind farm. Here we adapt a dynamic approach to determine subgrid-scale roughness parametrizations and apply it for the case of rough surfaces composed of cuboidal elements with broad size distributions, containing many scales. We first investigate the flow response to ground roughness of a few scales. LES with the dynamic roughness model which accounts for the drag of unresolved roughness is shown to provide resolution-independent results for the mean velocity distribution. Moreover, we develop an analytical roughness model that accounts for the sheltering effects of large-scale on small-scale roughness elements. Taking into account the shading effect, constraints from fundamental conservation laws, and assumptions of geometric self-similarity, the analytical roughness model is shown to provide analytical predictions that agree well with roughness parameters determined from LES.This article is part of the themed issue 'Wind energy in complex terrains'.

  1. Analytical study of flow and heat transfer in an annular porous medium subject to asymmetrical heat fluxes

    Science.gov (United States)

    Xu, Huijin; Zhao, Changying; Vafai, Kambiz

    2017-08-01

    Fully developed forced convective heat transfer in an annulus filled with a porous medium subject to asymmetrical heating is investigated analytically with different models in this work. The classic Darcy and Brinkman models were employed for the fluid flow, while the local thermal equilibrium (LTE) and the local thermal non-equilibrium (LTNE) models were employed to describe the heat transfer process in porous media. An analytical model based on fin theory was also employed for analyzing this problem. Exact solutions with Darcy-LTNE, Darcy-LTE, Brinkman-LTNE, Brinkman-LTE, and the fin models were obtained. Among these solutions, the Brinkman-LTNE solution can be treated as the benchmark, as it is a complete model, which covers the effect of viscous force near the solid wall and the temperature difference between the solid and fluid phases. The basic parameters that affect the velocity and temperature fields were analyzed in depth. The velocity and temperature profiles with these different models were also presented. The effects of some critical parameters on thermal performance of asymmetrically heated annulus fitted with a porous medium were discussed. The cited different analytical models were compared in detail with each other. The critical heat flux (HF) ratios for the inner and outer walls were presented in terms of a Nu- ξ curve for the five models. These solutions were developed for an asymmetrically heated annular channel filled with a porous medium, which can predict the thermal performance within a wide range of radii and HF ratios.

  2. Extended semi-analytical model for the prediction of flow and concentration fields in a tangentially-fired furnace

    Directory of Open Access Journals (Sweden)

    Lotfiani Amin

    2013-01-01

    Full Text Available Tangentially-fired furnaces (TFF are one of the modified types of furnaces which have become more attractive in the field of industrial firing systems in recent years. Multi-zone thermodynamic models can be used to study the effect of different parameters on the operation of TFF readily and economically. Flow and mixing sub-model is a necessity in multi-zone models. In the present work, the semi-analytical model previously established by the authors for the prediction of the behavior of coaxial turbulent gaseous jets is extended to be used in a single-chamber TFF with square horizontal cross-sections and to form the flow and mixing sub-model of the future multi-zone model for the simulation of this TFF. A computer program is developed to implement the new extended model. Computational fluid dynamics (CFD simulations are carried out to validate the results of the new model. In order to verify the CFD solution procedure, a turbulent round jet injected into cross flow is simulated. The calculated jet trajectory and velocity profile are compared with other experimental and numerical data and good agreement is observed. Results show that the present model can provide very fast and reasonable predictions of the flow and concentration fields in the TFF of interest.

  3. Analytical solutions of couple stress fluid flows with slip boundary conditions

    Directory of Open Access Journals (Sweden)

    Devakar M.

    2014-09-01

    Full Text Available In the present article, the exact solutions for fundamental flows namely Couette, Poiseuille and generalized Couette flows of an incompressible couple stress fluid between parallel plates are obtained using slip boundary conditions. The effect of various parameters on velocity for each problem is discussed. It is found that, for each of the problems, the solution in the limiting case as couple stresses approaches to zero is similar to that of classical viscous Newtonian fluid. The results indicate that, the presence of couple stresses decreases the velocity of the fluid.

  4. Analytical Investigation of Magnetohydrodynamic Flow over a Nonlinear Porous Stretching Sheet

    Directory of Open Access Journals (Sweden)

    Fazle Mabood

    2016-01-01

    Full Text Available We investigated the magnetohydrodynamic (MHD boundary layer flow over a nonlinear porous stretching sheet with the help of semianalytical method known as optimal homotopy asymptotic method (OHAM. The effects of different parameters on fluid flow are investigated and discussed. The obtained results are compared with numerical Runge-Kutta-Fehlberg fourth-fifth-order method. It is found that the OHAM solution agrees well with numerical as well as published data for different assigned values of parameters; this thus indicates the feasibility of the proposed method (OHAM.

  5. Evaluation of analytic solutions for steady interface flow where the aquifer extends below the sea

    Science.gov (United States)

    Bakker, Mark; Miller, Anthony D.; Morgan, Leanne K.; Werner, Adrian D.

    2017-08-01

    A computational approach is presented for steady Dupuit interface flow where the aquifer extends below the sea. A detailed approach is outlined to determine the head at the coastline so that the solution below the leaky seabed may be combined with any type of steady Dupuit interface flow in the aquifer below the land. The method allows for any inland boundary condition including specified head and specified flux; cases of freshwater lenses caused by infiltration are also considered. The approach is implemented in a Python script and a Jupyter Notebook.

  6. A semi-analytical model for the acoustic impedance of finite length circular holes with mean flow

    Science.gov (United States)

    Yang, Dong; Morgans, Aimee S.

    2016-12-01

    The acoustic response of a circular hole with mean flow passing through it is highly relevant to Helmholtz resonators, fuel injectors, perforated plates, screens, liners and many other engineering applications. A widely used analytical model [M.S. Howe. "Onthe theory of unsteady high Reynolds number flow through a circular aperture", Proc. of the Royal Soc. A. 366, 1725 (1979), 205-223] which assumes an infinitesimally short hole was recently shown to be insufficient for predicting the impedance of holes with a finite length. In the present work, an analytical model based on Green's function method is developed to take the hole length into consideration for "short" holes. The importance of capturing the modified vortex noise accurately is shown. The vortices shed at the hole inlet edge are convected to the hole outlet and further downstream to form a vortex sheet. This couples with the acoustic waves and this coupling has the potential to generate as well as absorb acoustic energy in the low frequency region. The impedance predicted by this model shows the importance of capturing the path of the shed vortex. When the vortex path is captured accurately, the impedance predictions agree well with previous experimental and CFD results, for example predicting the potential for generation of acoustic energy at higher frequencies. For "long" holes, a simplified model which combines Howe's model with plane acoustic waves within the hole is developed. It is shown that the most important effect in this case is the acoustic non-compactness of the hole.

  7. Analytical and numerical simulations of the flow performance of a ferrofluidic magnetic micropump for particle-laden applications

    Energy Technology Data Exchange (ETDEWEB)

    Kilani, M.I. [King Faisal Univ., Al-Ahsa (Saudi Arabia); Jordan Univ., Amman (Jordan). Dept. of Mechatronics Engineering; Al Halhouli, A.T.; Buttgenbach, S. [Inst. for Microtechnology, Braunschweig (Germany)

    2009-07-01

    New developments in micro-electro-mechanical systems (MEMS) are generating interest in micropump designs for the transport of small quantities of fluid samples. In this study, flow performance in a ferrofluidic magnetic micropump was investigated using analytical and numerical computational fluid dynamics (CFD) simulations. The aim of the study was to provide a method of estimating the stress distribution in the flow field in relation to pump speed and geometry in terms of dimensionless parameters. The pump was valveless, self-priming, bubble-tolerant, and capable of handling particle-laden fluids. Solutions were derived for the shear stress generated at the upper and lower boundaries of the pump's channel by solving the Navier-Stokes equation in cylindrical coordinates. A 3-D computational model of the pump's channel was constructed with different channel heights. The study demonstrated that shear stress is small in the majority of the pump's channel, and develops significant values only in narrow strips near the pump walls. Predictions obtained in the study showed good agreement with results obtained during the CFD simulations. However, CFD predictions were lower than analytical predictions for larger aspect ratios. It was concluded that the estimates provide an upper limit on shear stresses, and can be used to provide conservative estimates of shear stress. 10 refs., 7 figs.

  8. Analytical Solution for Fractional Derivative Gas-Flow Equation in Porous Media

    KAUST Repository

    El-Amin, Mohamed

    2017-07-06

    In this paper, we introduce an analytical solution of the fractional derivative gas transport equation using the power-series technique. We present a new universal transform, namely, generalized Boltzmann change of variable which depends on the fractional order, time and space. This universal transform is employed to transfer the partial differential equation into an ordinary differential equation. Moreover, the convergence of the solution has been investigated and found that solutions are unconditionally converged. Results are introduced and discussed for the universal variable and other physical parameters such as porosity and permeability of the reservoir; time and space.

  9. Flipping the analytical coin : closing the information flow loop in high speed (real time) analysis

    NARCIS (Netherlands)

    K.E. Shahroudi

    1997-01-01

    textabstractAnalysis modules tend to be set up as one way flow of information, i.e a clear distinction between cause and effect or input and output. However, as the speed of analysis approaches real time (or faster than movie rate), it becomes increasingly difficult for an external user to

  10. Flipping the analytical coin : closing the information flow loop in high speed (real time) analysis

    NARCIS (Netherlands)

    Shahroudi, K.E.

    1997-01-01

    Analysis modules tend to be set up as one way flow of information, i.e a clear distinction between cause and effect or input and output. However, as the speed of analysis approaches real time (or faster than movie rate), it becomes increasingly difficult for an external user to distinguish between c

  11. Evaluation and purchase of an analytical flow cytometer: some of the numerous factors to consider.

    Science.gov (United States)

    Zucker, Robert M; Fisher, Nancy C

    2013-01-01

    When purchasing a flow cytometer, the decision of which brand, model, specifications, and accessories may be challenging. The decisions should initially be guided by the specific applications intended for the instrument. However, many other factors need to be considered, which include hardware, software, quality assurance, support, service, and price and recommendations from colleagues. These issues are discussed to help guide the purchasing process.

  12. FLOW CYTOMETRY AS A MODERN ANALYTICAL TOOL IN BIOLOGY AND MEDICINE

    Directory of Open Access Journals (Sweden)

    S. V. Khaidukov

    2007-01-01

    Full Text Available Abstract. Flow cytometry is considered as a modern technology for fast measurements of cellular characteristics, their organelles, and processes occurring within them. It is regarded as an efficient solution in many important areas of cell biology, immunology and cellular engineering. Present article bears on main developments in flow cytometry and their applications in medical and biological practice. Usage of modern achievements in fluorescent dyes, progress in laser and computer technologies, as well as potent software, resulted in wide application of this technique in medical practice. Accordingly, usage of monoclonal antibodies conjugated to different fluorochromes has led to elaboration of multiparametric analysis and did sufficiently simplify specialized works aimed for diagnostics of various immune disorders. The new directions in flow cytometry, e.g., flow cytoenzymology, provide wide opportunities for detailed identification of damaged or altered cells, and taking adequate decisions in treatment of detected pathological changes. The authors suggest that this article could initiate a series of publications concerning usage of this technology and its modern applications in broad laboratory practice.

  13. The effect of aeration and recirculation on a sand-based hybrid constructed wetland treating low-strength domestic wastewater.

    Science.gov (United States)

    Zapater-Pereyra, M; Kyomukama, E; Namakula, V; van Bruggen, J J A; Lens, P N L

    2016-08-01

    The Duplex-constructed wetland (CW) is a hybrid system composed of a vertical flow (VF) CW on top of a horizontal flow filter (HFF). Each compartment is designed to play a different role: aerobic treatment in the VF CW due to intermittent feeding and anoxic treatment in the HFF due to saturated conditions. Three Duplex-CWs were used in this study: Control, Aerated and Recirculating. The role of each compartment was tested for pollutant removal and micro-invertebrate abundance. In all systems, the VF CW removed mainly organic matter, solids and NH4(+)-N. Pathogens were removed in both compartments. Likewise, total nitrogen removal occurred in both compartments, only the Recirculating HFF was not able to denitrify the nitrogen due to the slightly more oxic conditions as compared to the other systems. All systems met discharge guidelines for organic matter, but only the Control and Aerated systems met those for total nitrogen. At the applied loading rates, the pollutant removal was not significantly enhanced by the use of aeration and recirculation. Therefore, operation as in the Control system, without aeration or recirculation, is recommended for the tested Duplex-CWs. If artificial aeration will be used in CWs, the support material should be carefully selected to allow a proper air distribution.

  14. Toward an understanding of the effects of agitation and aeration on growth and laccases production by Pleurotus ostreatus.

    Science.gov (United States)

    Tinoco-Valencia, Raunel; Gómez-Cruz, Cristina; Galindo, Enrique; Serrano-Carreón, Leobardo

    2014-05-10

    Mycelial growth and laccase production by Pleurotus ostreatus CP50 cultured in a 10-L mechanically agitated bioreactor were assessed through a 2(3) factorial experimental design. The main effects and interactions of three factors (agitation, aeration and copper induction) over five responses (μ, αLacc, βLacc, maximal volumetric laccase activity and maximal biomass concentration) were analyzed. P. ostreatus growth was significantly improved when culturing was conducted with high agitation (5.9kW/m(3)s) and aeration flow (0.5vvm) rates. Under the experimental conditions evaluated, no evidence of hydrodynamic stress affecting fungal growth was observed. However, the high agitation and aeration conditions were detrimental for the growth-associated laccase production constant (αLacc), leading to a very complex optimization of the process. The maximal laccase volumetric activity (1.2 and 3.8U/ml for non-induced and copper-induced cultures, respectively) was observed when the culturing was performed at a low agitation rate (0.9kW/m(3)s) and a high aeration flow rate (0.5vvm). Laccase proteolysis may explain the complex interactions observed between agitation and aeration and the effects of these factors on the laccase volumetric activity observed in the cultures. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Effects of aeration method and aeration rate on greenhouse gas emissions during composting of pig feces in pilot scale.

    Science.gov (United States)

    Jiang, Tao; Li, Guoxue; Tang, Qiong; Ma, Xuguang; Wang, Gang; Schuchardt, Frank

    2015-05-01

    The aim of this study was to uncover ways to mitigate greenhouse gas (GHG) emissions and reduce energy consumption during the composting process. We assessed the effects of different aeration rates (0, 0.18, 0.36, and 0.54 L/(kg dry matter (dm)·min)) and methods (continuous and intermittent) on GHG emissions. Pig feces and corn stalks were mixed at a ratio of 7:1. The composting process lasted for 10 weeks, and the compost was turned approximately every 2 weeks. Results showed that both aeration rate and method significantly affected GHG emissions. Higher aeration rates increased NH3 and N2O losses, but reduced CH4 emissions. The exception is that the CH4 emission of the passive aeration treatment was lower than that of the low aeration rate treatment. Without forced aeration, the CH4 diffusion rates in the center of the piles were very low and part of the CH4 was oxidized in the surface layer. Intermittent aeration reduced NH3 and CH4 losses, but significantly increased N2O production during the maturing periods. Intermittent aeration increased the nitrification/denitrification alternation and thus enhanced the N2O production. Forced aeration treatments had higher GHG emission rates than the passive aeration treatment. Forced aeration accelerated the maturing process, but could not improve the quality of the end product. Compared with continuous aeration, intermittent aeration could increase the O2 supply efficiency and reduced the total GHG emission by 17.8%, and this reduction increased to 47.4% when composting was ended after 36 days.

  16. An analytic solution for periodic thermally-driven flows over an infinite slope

    Science.gov (United States)

    Zardi, Dino; Serafin, Stefano

    2013-04-01

    The flow generated along an infinite slope in an unperturbed stably stratified atmosphere at rest by a time periodic surface temperature forcing is examined. Following Defant (1949), a set of equations is derived which extends Prandtl's (1942) theory to allow for nonstationary conditions. Uniform boundary conditions are conducive to an along-slope parallel flow, governed by a periodically reversing local imbalance between along-slope advection and slope-normal fluxes of momentum and heat. Solutions include both a transient part and a subsequent periodic regime. The former can only be expressed in an integral form, whereas the latter is a combination of exponential and sine or cosine functions of time and height normal to the slope. Key parameters are the quantity Nα = N sinα (where α is the slope angle, and N is the Brunt-Väisälä frequency of the unperturbed atmosphere) and the angular frequency of the driving surface temperature cycle, ?. Three different flow regimes may occur, namely subcritical (Nα ?). The properties of the solutions in each regime are examined and discussed. The relationship between the present solutions and the earlier time-dependent slope flow model by Defant (1949) is also discussed. References Defant, F., 1949: Zur Theorie der Hangwinde, nebst Bemerkungen zur Theorie der Berg- und Talwinde. [A theory of slope winds, along with remarks on the theory of mountain winds and valley winds]. Arch. Meteor. Geophys. Bioclimatol., Ser. A, 1, 421-450 (Theoretical and Applied Climatology). [English translation: Whiteman, C.D., and E. Dreiseitl, 1984: Alpine meteorology: Translations of classic contributions by A. Wagner, E. Ekhart and F. Defant. PNL-5141 / ASCOT-84-3. Pacific Northwest Laboratory, Richland, Washington, 121 pp]. Prandtl, L., 1942: Strömungslehre [Flow Studies]. Vieweg und Sohn, Braunschweig, 382 pp.

  17. The Numerical and Analytical Study of Bifurcation and Multicellular Flow Instability Due to Natural Convection Between Narrow Horizontal Isothermal Cylindrical annuli at High Rayleigh Numbers.

    Science.gov (United States)

    1987-01-01

    studies, in general, have been much more limited. This thesis concentrates on the high Rayleigh number/small- gap flow regime. It has been found that...just prior to it. Analytical approaches, especially with regard to the high Rayleigh number/small- gap flow regime, have been virtually unexplored. To

  18. Finite volume approximation of the three-dimensional flow equation in axisymmetric, heterogeneous porous media based on local analytical solution

    KAUST Repository

    Salama, Amgad

    2013-09-01

    In this work the problem of flow in three-dimensional, axisymmetric, heterogeneous porous medium domain is investigated numerically. For this system, it is natural to use cylindrical coordinate system, which is useful in describing phenomena that have some rotational symmetry about the longitudinal axis. This can happen in porous media, for example, in the vicinity of production/injection wells. The basic feature of this system is the fact that the flux component (volume flow rate per unit area) in the radial direction is changing because of the continuous change of the area. In this case, variables change rapidly closer to the axis of symmetry and this requires the mesh to be denser. In this work, we generalize a methodology that allows coarser mesh to be used and yet yields accurate results. This method is based on constructing local analytical solution in each cell in the radial direction and moves the derivatives in the other directions to the source term. A new expression for the harmonic mean of the hydraulic conductivity in the radial direction is developed. Apparently, this approach conforms to the analytical solution for uni-directional flows in radial direction in homogeneous porous media. For the case when the porous medium is heterogeneous or the boundary conditions is more complex, comparing with the mesh-independent solution, this approach requires only coarser mesh to arrive at this solution while the traditional methods require more denser mesh. Comparisons for different hydraulic conductivity scenarios and boundary conditions have also been introduced. © 2013 Elsevier B.V.

  19. Modelling of fluid flow in tape casting of thin ceramics: Analytical approaches and numerical investigations

    DEFF Research Database (Denmark)

    Jabbaribehnam, Mirmasoud; Hattel, Jesper Henri

    2016-01-01

    components are dependent upon tape casting technology. One of the growing sciences in the processing of ceramics by tape casting is the use of fluid flow analysis to control and enhance the final tapes. The fluid dynamics analysis of the ceramic slurries during tape casting is an efficient mean to elucidate......Tape casting has been used to produce thin layers of ceramics that can be used as single layers or can be stacked and laminated into multilayered structures. Many startup products such as multilayered inductors, multilayered varistors, piezoelectrics, ceramic fuel cells and lithium ion battery...... the physical parameters crucial to the process. A review of the development of the tape casting process with particular focus on modelling the material flow is presented and in this context the current status is examined and future potential discussed....

  20. On the accuracy of analytical methods for turbulent flows near smooth walls

    Science.gov (United States)

    Absi, Rafik; Di Nucci, Carmine

    2012-09-01

    This Note presents two methods for mean streamwise velocity profiles of fully-developed turbulent pipe and channel flows near smooth walls. The first is the classical approach where the mean streamwise velocity is obtained by solving the momentum equation with an eddy viscosity formulation [R. Absi, A simple eddy viscosity formulation for turbulent boundary layers near smooth walls, C. R. Mecanique 337 (2009) 158-165]. The second approach presents a formulation of the velocity profile based on an analogy with an electric field distribution [C. Di Nucci, E. Fiorucci, Mean velocity profiles of fully-developed turbulent flows near smooth walls, C. R. Mecanique 339 (2011) 388-395] and a formulation for the turbulent shear stress. However, this formulation for the turbulent shear stress shows a weakness. A corrected formulation is presented. Comparisons with DNS data show that the classical approach with the eddy viscosity formulation provides more accurate profiles for both turbulent shear stress and velocity gradient.

  1. Analytical modeling for the heat transfer in sheared flows of nanofluids

    CERN Document Server

    Ferrari, Claudio; L'vov, Victor S; Procaccia, Itamar; Rudenko, Oleksii; Boonkkamp, J H M ten Thije; Toschi, Federico

    2012-01-01

    We developed a model for the enhancement of the heat flux by spherical and elongated nano- particles in sheared laminar flows of nano-fluids. Besides the heat flux carried by the nanoparticles the model accounts for the contribution of their rotation to the heat flux inside and outside the particles. The rotation of the nanoparticles has a twofold effect, it induces a fluid advection around the particle and it strongly influences the statistical distribution of particle orientations. These dynamical effects, which were not included in existing thermal models, are responsible for changing the thermal properties of flowing fluids as compared to quiescent fluids. The proposed model is strongly supported by extensive numerical simulations, demonstrating a potential increase of the heat flux far beyond the Maxwell-Garnet limit for the spherical nanoparticles. The road ahead which should lead towards robust predictive models of heat flux enhancement is discussed.

  2. Modelling of fluid flow in tape casting of thin ceramics: Analytical approaches and numerical investigations

    DEFF Research Database (Denmark)

    Jabbaribehnam, Mirmasoud; Hattel, Jesper Henri

    2016-01-01

    Tape casting has been used to produce thin layers of ceramics that can be used as single layers or can be stacked and laminated into multilayered structures. Many startup products such as multilayered inductors, multilayered varistors, piezoelectrics, ceramic fuel cells and lithium ion battery...... components are dependent upon tape casting technology. One of the growing sciences in the processing of ceramics by tape casting is the use of fluid flow analysis to control and enhance the final tapes. The fluid dynamics analysis of the ceramic slurries during tape casting is an efficient mean to elucidate...... the physical parameters crucial to the process. A review of the development of the tape casting process with particular focus on modelling the material flow is presented and in this context the current status is examined and future potential discussed....

  3. Analytical Studies of Two-Dimensional Channel Turbulent Flow Subjected to Coriolis Force

    OpenAIRE

    鬼頭, 修己; 中林, 功一; キトウ, オサミ; Kito, Osami

    1992-01-01

    Coriolis effects on fully developed turbulent flow in a two-dimensional channel rotating about an axis perpendicular to its axis are considered. The Coriolis force has stabilizing/destabilizing effects on turbulence, and the mean velocity distribution changes accordingly. Experimental and numerical studies on the velocity characteristics have already been conducted by other researchers for various conditions. However, we cannot assemble the overall picture of the Coriolis effect on the veloci...

  4. Exact analytical solutions for axial flow of a fractional second grade fluid between two coaxial cylinders

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    The velocity field and the adequate shear stress corresponding to the longitudinal flow of a fractional second grade fluid,between two infinite coaxial circular cylinders,are determined by applying the Laplace and finite Hankel transforms.Initially the fluid is at rest,and at time t=0~+, the inner cylinder suddenly begins to translate along the common axis with constant acceleration. The solutions that have been obtained are presented in terms of generalized G functions.Moreover, these solutions satisfy ...

  5. Web-Based Predictive Analytics to Improve Patient Flow in the Emergency Department

    Science.gov (United States)

    Buckler, David L.

    2012-01-01

    The Emergency Department (ED) simulation project was established to demonstrate how requirements-driven analysis and process simulation can help improve the quality of patient care for the Veterans Health Administration's (VHA) Veterans Affairs Medical Centers (VAMC). This project developed a web-based simulation prototype of patient flow in EDs, validated the performance of the simulation against operational data, and documented IT requirements for the ED simulation.

  6. Unified Analytical Solution for Radial Flow to a Well in a Confined Aquifer

    CERN Document Server

    Mishra, Phoolendra Kumar

    2011-01-01

    Drawdowns generated by extracting water from a large diameter (e.g. water supply) well are affected by wellbore storage. We present an analytical solution in Laplace transformed space for drawdown in a uniform anisotropic aquifer caused by withdrawing water at a constant rate from a partially penetrating well with storage. The solution is back transformed into the time domain numerically. When the pumping well is fully penetrating our solution reduces to that of Papadopulos and Cooper [1967]; Hantush [1964] when the pumping well has no wellbore storage; Theis [1935] when both conditions are fulfilled and Yang et.al. [2006] when the pumping well is partially penetrating, has finite radius but lacks storage. We use our solution to explore graphically the effects of partial penetration, wellbore storage and anisotropy on time evolutions of drawdown in the pumping well and in observation wells.

  7. Analytical Predictions of Field and Plasma Dynamics during Nonlinear Weibel-Mediated Flow Collisions

    Science.gov (United States)

    Ruyer, C.; Gremillet, L.; Bonnaud, G.; Riconda, C.

    2016-08-01

    The formation of collisionless shocks mediated by the ion Weibel instability is addressed theoretically and numerically in the nonrelativistic limit. First, the model developed in C. Ruyer et al., Phys. Plasmas 22, 032102 (2015) for the weakly nonlinear ion Weibel instability in a symmetric two-stream system is shown to be consistent with recent experimental and simulation results. Large-scale kinetic simulations are then performed to clarify the spatiotemporal evolution of the magnetic-field and plasma properties in the subsequent strongly nonlinear phase leading to shock formation. A simple analytical model is proposed which captures the simulation results up to a point close to ion isotropization. Electron screening effects are found important in the instability dynamics, so that numerical simulations using a nonphysical electron mass should be considered with caution.

  8. Analytical solutions Of three-dimensional contaminant transport in uniform flow field in porous media: A library

    Institute of Scientific and Technical Information of China (English)

    Hongtao WANG; Huayong WU

    2009-01-01

    The purpose of this study is to present a library of analytical solutions for the three-dimensional contam-inant transport in uniform flow field in porous media with the first-order decay, linear sorption, and zero-order pro-duction. The library is constructed using Green's function method (GFM) in combination with available solutions.The library covers a wide range of solutions for various conditions. The aquifer can be vertically finite, semi-infin-itive or infinitive, and laterally semi-infinitive or infinitive.The geometry of the sources can be of point, line, plane or volumetric body; and the source release can be continuous,instantaneous, or by following a given function over time.Dimensionless forms of the solutions are also proposed. A computer code FlowCAS is developed to calculate the solutions. Calculated results demonstrate the correctness of the presented solutions. The library is widely applicable to solve contaminant transport problems of one- or multiple- dimensions in uniform flow fields.

  9. Analytical Calculation of Stall-inception and Surge Points for an Axial-flow Compresor Rotor

    OpenAIRE

    Moreno Benavides, Efren; López Juste, Gregorio

    2012-01-01

    Recently, a theoretical criterion to calculate the stability of an axial-flow compressor rotor has been presented in the scientific literature. This theoretical criterion was used for determining the locus of the stability line over the rotor map and for predicting the post-stall evolution of the constant-speed line of a rotor. The main objective of this paper is to improve the predictions of such a model. To do that, the paper proposes a different characterization of the characteristic az...

  10. Flow Injection and Atomic Absorption Spectrometry - An Effective and Attractive Analytical Chemical Combination

    DEFF Research Database (Denmark)

    Hansen, Elo Harald; Nielsen, Steffen

    1998-01-01

    One of the advantages of the flow injection (FI) concept is that it is compatible with virtually all detection techniques. Being a versatile vehicle for enhancing the performance of the individual detection devices, the most spectacular results have possibly been obtained in conjunction with atomic...... is subjected to in FI from the point of injection/introduction to the point of detection, which in turn allows suitable on-line pretreatments to be effected. The present paper will - via a number of selected examples - point to some of the potentials at hand, encompassing the use of FI as a suitable vehicle...

  11. Effects of Aeration Treatment on γ-Aminobutyric Acid Accumulation in Germinated Tartary Buckwheat (Fagopyrum tataricum

    Directory of Open Access Journals (Sweden)

    Yuanxin Guo

    2016-01-01

    Full Text Available To explore the optimum condition of γ-aminobutyric acid (GABA accumulation in germinated tartary buckwheat, effects of some factors including aeration treatment, physiological indexes, air flow rate, culture temperature, and pH value of cultivating solution under hypoxia on GABA in germinated tartary buckwheat were investigated. The results showed that the dark cultures with distilled water at 30°C, 2 days, and aeration stress with 1.0 L/min air flow rate at 30°C were optimal for GABA accumulation. Under these conditions, the predicted content of GABA was up to 371.98 μg/g DW. The analysis of correlation indicated that there was a significant correlation (P<0.01 between GABA accumulation and physiological indexes. Box-Behnken experimental analysis revealed that optimal conditions with aeration treatment for GABA accumulation in germinated tartary buckwheat were air flow rate of 1.04 L/min, culture temperature of 31.25°C, and a pH value of 4.21. Under these conditions, the GABA content was predicted as high as 386.20 μg/g DW, which was close to the measured value (379.00±9.30 μg/g DW. The variance analysis and validation test suggested that this established regression model could predict GABA accumulation in tartary buckwheat during germination.

  12. A New Control and Design of PEM Fuel Cell System Powered Diffused Air Aeration System

    Directory of Open Access Journals (Sweden)

    Ninet M. Ahmed

    2012-06-01

    Full Text Available The goal of aquaculture ponds is to maximize production and profits while holding labor and management efforts to the minimum. Poor water quality in most ponds causes risk of fish kills, disease outbreaks which lead to minimization of pond production. Dissolved Oxygen (DO is considered to be among the most important water quality parameters in fish culture. Fish ponds in aquaculture farms are usually located in remote areas where grid lines are at far distance. Aeration of ponds is required to prevent mortality and to intensify production, especially when feeding is practical, and in warm regions. To increase pond production it is necessary to control dissolved oxygen. Aeration offers the most immediate and practical solution to water quality problems encountered at higher stocking and feeding rates. Many units of aeration system are electrical units so using a continuous, high reliability, affordable, and environmentally friendly power sources is necessary. Fuel cells have become one of the major areas of research in the academia and the industry. Aeration of water by using PEM fuel cell power is not only a new application of the renewable energy, but also, it provides an affordable method to promote biodiversity in stagnant ponds and lakes. This paper presents a new design and control of PEM fuel cell powered a diffused air aeration system for a shrimp farm in Mersa Matruh in Egypt. Also Artificial intelligence (AI control techniques are used to control the fuel cell output power by controlling its input gases flow rate. Moreover the mathematical modeling and simulation of PEM fuel cell is introduced. A comparative study is applied between the performance of fuzzy logic controller (FLC and neural network controller (NNC. The results show the effectiveness of NNC over FLC.

  13. A New Control and Design of PEM Fuel Cell System Powered Diffused Air Aeration System

    Directory of Open Access Journals (Sweden)

    Hassen T. Dorrah

    2012-06-01

    Full Text Available The goal of aquaculture ponds is to maximize production and profits while holding labor and management efforts to the minimum. Poor water quality in most ponds causes risk of fish kills, disease outbreaks which lead to minimization of pond production. Dissolved Oxygen (DO is considered to be among the most important water quality parameters in fish culture. Fish ponds in aquaculture farms are usually located in remote areas where grid lines are at far distance. Aeration of ponds is required to prevent mortality and to intensify production, especially when feeding is practical, and in warm regions. To increase pond production it is necessary to control dissolved oxygen. Aeration offers the most immediate and practical solution to water quality problems encountered at higher stocking and feeding rates. Many units of aeration system are electrical units so using a continuous, high reliability, affordable, and environmentally friendly power sources is necessary. Fuel cells have become one of the major areas of research in the academia and the industry. Aeration of water by using PEM fuel cell power is not only a new application of the renewable energy, but also, it provides an affordable method to promote biodiversity in stagnant ponds and lakes. This paper presents a new design and control of PEM fuel cell powered a diffused air aeration system for a shrimp farm in Mersa Matruh in Egypt. Also Artificial intelligence (AI control techniques are used to control the fuel cell output power by controlling its input gases flow rate. Moreover the mathematical modeling and simulation of PEM fuel cell is introduced. A comparative study is applied between the performance of fuzzy logic controller (FLC and neural network controller (NNC. The results show the effectiveness of NNC over FLC.

  14. Allocation of supplementary aeration stations in the Chicago waterway system for dissolved oxygen improvement.

    Science.gov (United States)

    Alp, Emre; Melching, Charles S

    2011-06-01

    The Chicago Waterway System (CWS), used mainly for commercial and recreational navigation and for urban drainage, is a 122.8 km branching network of navigable waterways controlled by hydraulic structures. The CWS receives pollutant loads from 3 of the largest wastewater treatment plants in the world, nearly 240 gravity Combined Sewer Overflows (CSO), 3 CSO pumping stations, direct diversions from Lake Michigan, and eleven tributary streams or drainage areas. Even though treatment plant effluent concentrations meet the applicable standards and most reaches of the CWS meet the applicable water quality standards, Dissolved Oxygen (DO) standards are not met in the CWS during some periods. A Use Attainability Analysis was initiated to evaluate what water quality standards can be achieved in the CWS. The UAA team identified several DO improvement alternatives including new supplementary aeration stations. Because of the dynamic nature of the CWS, the DUFLOW model that is capable of simulating hydraulics and water quality processes under unsteady-flow conditions was used to evaluate the effectiveness of new supplementary aeration stations. This paper details the use of the DUFLOW model to size and locate supplementary aeration stations. In order to determine the size and location of supplemental aeration stations, 90% compliance with a 5 mg/l DO standard was used as a planning target. The simulations showed that a total of four new supplementary aeration stations with oxygen supply capacities ranging from 30 to 80 g/s would be sufficient to meet the proposed target DO concentration for the North Branch and South Branch of the Chicago River. There are several aeration technologies, two of which are already being used in the CWS, available and the UAA team determined that the total capital costs of the alternatives range from $35.5 to $89.9 million with annual operations and maintenance costs ranging from $554,000 to $2.14 million. Supplemental aeration stations have been

  15. Design characteristics of Curved Blade Aerator w.r.t. aeration ...

    African Journals Online (AJOL)

    user

    energy requirements of a secondary waste-water treatment plan (Wasner et al, 1977). Dissolved oxygen ... aquaculture industry, however, are different than those of the waste-water treatment industry. ...... European Water Management Online, EWA 2002. ... Process design of aeration system for biological waste treatment.

  16. Hydroplaning of subaqueous debris flows and glide blocks: Analytical solutions and discussion

    Science.gov (United States)

    Harbitz, Carl B.; Parker, Gary; ElverhøI, Anders; Marr, Jeffrey G.; Mohrig, David; Harff, Peter A.

    2003-07-01

    Subaqueous debris flows often attain significantly higher velocities and longer run-out distances than their subaerial counterparts in spite of increased viscous drag and reduced effective gravity due to buoyancy. Recent experimental research suggests that a basal lubricating layer of water associated with hydroplaning decouples the sediments from the bed, resulting in a dramatic reduction of the basal shear stress. Hydroplaning thus provides an explanation for these observations. The conditions for onset of hydroplaning are discussed in terms of critical densimetric Froude number. The stress reduction due to a lubricating layer of water or mud slurry is studied via equilibrium solutions for a two-layer Couette flow. The calculations reveal that the stresses in both the low-viscosity lubricating layer and the high-viscosity deforming deposits below it are substantially reduced. The principles of laminar boundary layers are used to develop an equilibrium solution for the steady motion of a hydroplaning debris glide block. This adjusted version of lubrication theory properly accounts for hydroplaning associated with a dynamic pressure generated at the head of the block. Example calculations at both laboratory and field scale support the experimental results of reduced bed friction, limited erosion, sediment rheology independence, and high velocities. The results also reveal the possibility for a net up-slope discharge in the lubricating layer.

  17. INFLUENCE OF SODIUM GLUTAMATE, BUBBLING N2- GAS AND SUPERFICIAL AERATION ON TETANUS TOXIN PRODUCTION IN Clostridium tetani CULTURES

    Directory of Open Access Journals (Sweden)

    I. Gutiérrez

    2005-12-01

    Full Text Available The influence of sodium glutamate as a supplement to Latham Mueller medium, while using bubbling nitrogen flow as an anaerobic agent and superficial aeration as an inducer of cell lysis and as a mechanism for the haulage of gases in the fermentation processes was evaluated. Using the Clostridium tetani Massachusetts’s strain, several five (5 liter batch fermentations were carried out for tetanus toxin production under the following conditions: Latham Mueller medium, with or without sodium glutamate, nitrogen flow and superficial aeration. The results demonstrated that the addition of sodium glutamate (2.5 g/l, combined with a bubbling nitrogen flow (0.33 l/min and superficial aeration (0.33 l/min, produced a significant increase in cell concentrations, repressing the tetanus toxin formation; while the gas flow (nitrogen and superficial aeration without sodium glutamate improved the toxin production by approximately 49%, providing conditions for the following outcomes: a maximum toxin level of 73 Lf/ml; a toxin formation rate of 1844.0 Lf/l.h; and, an over-all productivity of 833.5 Lf/l.h.

  18. Analytical solution for peristaltic flow of conducting nanofluids in an asymmetric channel with slip effect of velocity, temperature and concentration

    Directory of Open Access Journals (Sweden)

    S. Sreenadh

    2016-06-01

    Full Text Available The Peristaltic transport of conducting nanofluids under the effect of slip condition in an asymmetric channel is reported in the present work. The mathematical modelling has been carried out under long wavelength and low Reynolds number approximations. The analytical solutions are obtained for pressure rise, nanoparticle concentration, temperature distribution, velocity profiles and stream function. Influence of various parameters on the flow characteristics has been discussed with the help of graphs. The results showed that the pressure rise increases with increasing magnetic effect and decreases with increasing slip parameter. The effects of thermophoresis parameter and Brownian motion parameter on the nanoparticle concentration and temperature distribution are studied. It is observed that the pressure gradient increases with increasing slip parameter and magnetic effect. The trapping phenomenon for different parameters is presented.

  19. Analytical series solution for the fully developed forced convection duct flow with frictional heating and variable viscosity

    Energy Technology Data Exchange (ETDEWEB)

    Magyari, E. [ETH-Zuerich, Institute of Building Technology, Zuerich (Switzerland); Barletta, A. [Universita di Bologna, Dipartimento di Ingegneria Energetica, Nucleare e del Controllo Ambientale (DIENCA), Bologna (Italy)

    2007-12-15

    Laminar forced convection flow of a liquid in the fully developed region of a circular duct with isothermal wall is analyzed. The effects of viscous dissipation as well as of temperature dependent viscosity are taken into account. The coupled momentum and energy equations are solved analytically by means of a power series method. Then, reference is made to the Poiseuille model for the temperature change of viscosity. For a fixed value of the axial pressure gradient along the duct, dual solutions are found for the velocity and temperature fields. Although dual solutions correspond to the same value of the axial pressure gradient, they lead in general to different values of the average fluid velocity, of the average fluid temperature and of the wall heat flux. It is shown that, for a given fluid and for a fixed duct radius, the absolute value of the axial pressure gradient has an upper bound above which no steady laminar solution can exist. (orig.)

  20. Study on blood flow containing nanoparticles through porous arteries in presence of magnetic field using analytical methods

    Science.gov (United States)

    Ghasemi, Seiyed E.; Hatami, M.; Sarokolaie, A. Kalani; Ganji, D. D.

    2015-06-01

    In this paper, flow analysis for a third grade non-Newtonian blood in porous arteries in presence of magnetic field is simulated analytically and numerically. Blood is considered as the third grade non-Newtonian fluid containing nanoparticles. Collocation Method (CM) and Optimal Homotopy Asymptotic Method (OHAM) are used to solve the Partial Differential Equation (PDE) governing equation which a good agreement between them was observed in the results. The influences of the some physical parameters such as Brownian motion parameter, pressure gradient and thermophoresis parameter, etc. on temperature, velocity and nanoparticles concentration profiles are considered. For instance, increasing the thermophoresis parameter (Nt) caused an increase in temperature values in whole domain and an increase in nanoparticles concentration near the inner wall.

  1. Analytical solution to stagnation-point flow and heat transfer over a stretching sheet based on homotopy analysis

    Institute of Scientific and Technical Information of China (English)

    Jing ZHU; Lian-cun ZHENG; Xin-xin ZHANG

    2009-01-01

    This paper is concerned with two-dimensional stagnation-point steady flow of an incompressible viscous fluid towards a stretching sheet whose velocity is proportional to the distance from the slit. The governing system of partial differential equations is first transformed into a system of dimensionless ordinary differential equations. Analytical solutions of the velocity distribution and dimensionless temperature profiles are obtained for different ratios of free stream velocity and stretching velocity, Prandtl number, Eckert number and dimensionality index in series forms using homotopy analysis method(HAM).It is shown that a boundary layer is formed when the free stream velocity exceeds the stretching velocity, and an inverted boundary layer is formed when the free stream velocity is less than the stretching velocity. Graphs are presented to show the effects of different parameters.

  2. Electropolymerization of pyrrole and immobilization of glucose oxidase in a flow system: influence of the operating conditions on analytical performance.

    Science.gov (United States)

    Vidal, J C; Garcia, E; Castillo, J R

    1998-03-01

    The in situ potentiostatic electropolymerization of pyrrole (Py) on a Pt electrode in a thin-layer amperometric cell and the entrapment of the enzyme glucose oxidase (GOx) for the determination of glucose are reported. Polypyrrole (PPy) is directly formed by continuous passage of a buffered solution of the monomer (0.4 M) and enzyme (250 U mL-1) at pH 7 at a flow rate of 0.05-0.1 mL min-1 under a constant applied potential of +0.85 V vs Ag/AgCl decreases. The electrosynthesis of PPy by injection of 500 microL of a Py + GOx solution in a carrier electrolyte consisting of 0.05 M phosphate buffer and 0.1 M KCl at pH 7.0 was also assayed. The influence of the electropolymerization conditions on the analytical response of the sensor to glucose was investigated. The analytical performance of the PPy/GOx sensor was also studied in terms of durability and storage life, as well as selectivity against electroactive species such as ascorbic acid and uric acid as a function of the thickness of the polymer film formed.

  3. 2-D Analysis of Enhancement of Analytes Adsorption Due to Flow Stirring by Electrothermal Force in The Microcantilever Sensor

    CERN Document Server

    Wu, M C; Yang, C -K

    2008-01-01

    Ac electrokinetic flows are commonly used for manipulating micron-scale particles in a biosensor system. At the solid-liquid state there are two kinds of processes in the reaction between analytes and ligands: the mass transport process and the chemical reaction process. The mass transport process is related to convection and diffusion. Total or partial limit of mass transport would retard the diffusion from the bulk fluid to the interface of reaction. This effect decreases the possibility of adsorption of analyte and ligand because the chemical reaction is faster than the diffusion. In order to solve this problem, we apply an ac electric field to induce a vortex field by the electrothermal effect, which helps in increasing the rate of diffusion. By using the finite element analysis software, COMSOL Multiphysics, we optimized several parameters of the microelectrode structures and the position of the reacting surface, i.e. the microcantilever, by a simplified 2-D model and a 3-D model. It is successful in acc...

  4. Analytical Investigation of Laminar Viscoelastic Fluid Flow over a Wedge in the Presence of Buoyancy Force Effects

    Directory of Open Access Journals (Sweden)

    B. Rostami

    2014-01-01

    Full Text Available An analytical strong method, the homotopy analysis method (HAM, is employed to study the mixed convective heat transfer in an incompressible steady two-dimensional viscoelastic fluid flow over a wedge in the presence of buoyancy effects. The two-dimensional boundary-layer governing partial differential equations (PDEs are derived by the consideration of Boussinesq approximation. By the use of similarity transformation, we have obtained the ordinary differential nonlinear (ODE forms of momentum and energy equations. The highly nonlinear forms of momentum and energy equations are solved analytically. The effects of different involved parameters such as viscoelastic parameter, Prandtl number, buoyancy parameter, and the wedge angle parameter, which is related to the exponent m of the external velocity, on velocity and temperature distributions are plotted and discussed. An excellent agreement can be seen between the results and the previously published papers for f′′(0 and θ′(0 in some of the tables and figures of the paper for velocity and temperature profiles for various values of viscoelastic parameter and Prandtl number. The effects of buoyancy parameter on the velocity and temperature distributions are completely illustrated in detail.

  5. A multi-quadric area-sink for analytic element modeling of groundwater flow

    Science.gov (United States)

    Strack, O. D. L.; Janković, I.

    1999-12-01

    It is shown that the approach presented by Strack (Strack, O.D.L., 1989. Groundwater Mechanics. Prentice Hall, New Jersey) for determining the discharge potential for an area-sink leads to a function that is unique except for an arbitrary constant. The approach is applied to a special area-sink, namely one with an extraction rate that varies inside a polygon as a multi-quadric interpolator (Hardy, R.L., 1971. Multiquadric equations of topography and other irregular surfaces. Journal of Geophysical Research 76, 1905-1915). The principle of over-specification presented by Janković and Barnes (Janković, I., Barnes, R., 1999a. Three-dimensional flow through large numbers of spheroidal inhomogeneities. Journal of Hydrology 226, 224-233), is used to obtain an approximate solution. Several examples are presented herewith.

  6. Unsteady rotating laminar flow: analytical solution of relevant Navier-Stokes equations

    CERN Document Server

    Bocci, Alessio; Ritelli, Daniele

    2016-01-01

    We provide a integration of Navier-Stokes equations concerning the unsteady-state laminar flow of an incompressible, isothermal (newtonian) fluid in a cylindrical vessel spinning about its symmetry axis, say $z$, and inside which the liquid velocity starts with a non-zero axial component as well. Basic physical assumptions are that the pressure axial gradient keeps itself on its hydrostatic value and that no radial velocity exists. In such a way the PDEs become uncoupled and can be faced separately from each other. We succeed in computing both the unsteady velocities, i.e. the axial $v_z$ and the circumferential $v_\\theta$ as well, by means of infinite series expansions of Fourier-Bessel type under time exponential damping. Following this, we also find the unsteady surfaces of dynamical equilibrium, the wall shear stress and the Stokesian streamlines

  7. Modeling flow in porous media with double porosity/permeability: Mathematical model, properties, and analytical solutions

    CERN Document Server

    Nakshatrala, K B; Ballarini, R

    2016-01-01

    Geo-materials such as vuggy carbonates are known to exhibit multiple spatial scales. A common manifestation of spatial scales is the presence of (at least) two different scales of pores, which is commonly referred to as double porosity. To complicate things, the pore-network at each scale exhibits different permeability, and these networks are connected through fissure and conduits. Although some models are available in the literature, they lack a strong theoretical basis. This paper aims to fill this lacuna by providing the much needed theoretical foundations of the flow in porous media which exhibit double porosity/permeability. We first obtain a mathematical model for double porosity/permeability using the maximization of rate of dissipation hypothesis, and thereby providing a firm thermodynamic underpinning. We then present, along with mathematical proofs, several important mathematical properties that the solutions to the double porosity/permeability model satisfy. These properties are important in their...

  8. Analytic Study of Magnetohydrodynamic Flow and Boundary Layer Control Over a Wedge

    Institute of Scientific and Technical Information of China (English)

    M. Chandrasekar; S. Baskaran

    2008-01-01

    A genuine variational principle developed by Gyarmati, in the field of thermodynamics of irreversible processes unifying the theoretical requirements of technical, environmental and biological sciences is employed to study the effects of uniform suction and injection on MHD flow adjacent to an isothermal wedge with pressure gradient in the presence of a transverse magnetic field. The velocity distribution inside the boundary layer has been considered as a simple polynomial function and the variational principle is formulated. The Euler-Lagrange equation is reduced to a simple polynomial equation in terms of momentum boundary layer thickness. The velocity profiles, displacement thickness and the coefficient of skin friction are calculated for various values of wedge angle parameter m, magnetic parameter ε and suction/injection parameter H. The present results are compared with known available results and the comparison is found to be satisfactory. The present study establishes high accuracy of results obtained by this variational technique.

  9. An approximate analytical solution for non-Darcy flow toward awell infractured media

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Yu-Shu

    2001-06-08

    Estuarine suspended sediment is transported in a mixed nonuniform way under unsteady flows. Sediment of different grain sizes has different characteristics and transport behavior and has a different effect on the ecological system. Therefore classification and fractionization of the mixed sediment are required before the flux is estimated. A fuzzy clustering approach is applied to the classification of suspended fine-grained sediment in the Changjiang Estuary. Two populations are objectively found by considering the standard grain-size distribution statistics of each cluster. The critical grain size of {approx}10??m in diameter is the size limit for cohesive sediments. A grid with equal cell areas is used to estimate fractional sediment fluxes through an estuarine cross section since this type of grid introduces less statistical error in the flux calculation. The sediment transport mechanism is analyzed.

  10. Characterization of performance reference compound kinetics and analyte sampling rate corrections under three flow regimes using nylon organic chemical integrative samplers.

    Science.gov (United States)

    Morrison, Shane A; Belden, Jason B

    2016-09-30

    Performance reference compounds (PRCs) can be spiked into passive samplers prior to deployment. If the dissipation kinetics of PRCs from the sampler corresponds to analyte accumulation kinetics, then PRCs can be used to estimate in-situ sampling rates, which may vary depending on environmental conditions. Under controlled laboratory conditions, the effectiveness of PRC corrections on prediction accuracy of water concentrations were evaluated using nylon organic chemical integrative samplers (NOCIS). Results from PRC calibrations suggest that PRC elimination occurs faster under higher flow conditions; however, minimal differences were observed for PRC elimination between fast flow (9.3cm/s) and slow flow (5.0cm/s) conditions. Moreover, minimal differences were observed for PRC elimination from Dowex Optipore L-493; therefore, PRC corrections did not improve results for NOCIS configurations containing Dowex Optipore L-493. Regardless, results suggest that PRC corrections were beneficial for NOCIS configurations containing Oasis HLB; however, due to differences in flow dependencies of analyte sampling rates and PRC elimination rates across the investigated flow regimes, the use of multiple PRC corrections was necessary. As such, a "Best-Fit PRC" approach was utilized for Oasis HLB corrections using caffeine-(13)C3, DIA-d5, or no correction based on the relative flow dependencies of analytes and these PRCs. Although PRC corrections reduced the variability when in-situ conditions differed from laboratory calibrations (e.g. static versus moderate flow), applying PRC corrections under similar flow conditions increases variability in estimated values.

  11. Analytical solutions for benchmarking cold regions subsurface water flow and energy transport models: one-dimensional soil thaw with conduction and advection

    Science.gov (United States)

    Kurylyk, Barret L.; McKenzie, Jeffrey M; MacQuarrie, Kerry T. B.; Voss, Clifford I.

    2014-01-01

    Numerous cold regions water flow and energy transport models have emerged in recent years. Dissimilarities often exist in their mathematical formulations and/or numerical solution techniques, but few analytical solutions exist for benchmarking flow and energy transport models that include pore water phase change. This paper presents a detailed derivation of the Lunardini solution, an approximate analytical solution for predicting soil thawing subject to conduction, advection, and phase change. Fifteen thawing scenarios are examined by considering differences in porosity, surface temperature, Darcy velocity, and initial temperature. The accuracy of the Lunardini solution is shown to be proportional to the Stefan number. The analytical solution results obtained for soil thawing scenarios with water flow and advection are compared to those obtained from the finite element model SUTRA. Three problems, two involving the Lunardini solution and one involving the classic Neumann solution, are recommended as standard benchmarks for future model development and testing.

  12. 21 CFR 880.6100 - Ethylene oxide gas aerator cabinet.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ethylene oxide gas aerator cabinet. 880.6100... Miscellaneous Devices § 880.6100 Ethylene oxide gas aerator cabinet. (a) Identification. An ethyene oxide gas... required to remove residual ethylene oxide (ETO) from wrapped medical devices that have undergone ETO...

  13. OXIDATION OF AS(III) BY AERATION AND STORAGE

    Science.gov (United States)

    A study of the effects of aeration and storage on the oxidation of arsenic(III) was undertaken at three utilities in the US to establish the engineering significance of aeration as a potential pre-treatment method for arsenic removal. The results of this study clearly establish t...

  14. Evaluation of oscillatory integrals for analytical groundwater flow and mass transport models

    Science.gov (United States)

    Ledder, Glenn; Zlotnik, Vitaly A.

    2017-06-01

    Modeling of transient dynamics of an interface between fluids of identical density and viscosity, but different otherwise, is of great interest in aquifer hydraulic, and advective contaminant transport, and has broad application. Closed-form solutions are often available for problems with simple, practically important geometry, but the integrals that appear in such solutions often have integrands with two or more oscillatory factors. Such integrals pose difficulties for numerical evaluation because the positive and negative contributions of the integrand largely cancel and the integrands decay very slowly in the integration domain. Some problems with integrands with a single oscillatory factor were tackled in the past with an integration/summation/extrapolation (ISE) method: breaking the integrand at consecutive zeros to obtain an alternating series and then using the Shanks algorithm to accelerate convergence of the series. However, this technique is ineffective for problems with multiple oscillatory factors. We present a comprehensive strategy for evaluation of such integrals that includes a better ISE method, an interval truncation method, and long-time asymptotics; this strategy is applicable to a large class of integrals with either single or multiple oscillatory factors that arise in modeling of groundwater flow and transport. The effectiveness of this methodology is illustrated by examples of integrals used in well hydraulics, groundwater recharge design, and particle tracking.

  15. On the exact analytical solution for the spatial moments of the cross-sectional average concentration in open channel flows

    Science.gov (United States)

    Pannone, Marilena

    2012-08-01

    This paper shows how an exact analytical solution for the transient-state spatial moments of the cross-sectional average tracer concentration in large open channel flows can be derived from the depth-averaged advection-diffusion equation resorting to the method of Green's functions, without any simplifying assumption about the regularity of the actual concentration field, the smallness of the fluctuations, or the large space-time scale of variation of the average concentration gradient (justifying the a priori localization of the problem), which were the basis of the classic Taylor dispersion theory. The results reveal that in agreement with the findings by Aris (1956) and later by others for flows within a conduit, there are an initial centroid displacement and a variance deficit dependent on the specific position and dimension of the initial injection. The second central moment asymptotically tends to the linearly increasing function predictable on the basis of Taylor's classic theory, and the skewness, which is constantly zero for the cross-sectionally uniform injection, in the case of nonuniform initial distributions tends to slowly vanish after having reached a maximum. Thus, the persistent asymmetry exhibited by the field concentration data, as well as the retardations and the accelerations in the peak trajectory, can be justified without making any a priori assumption about the physical mechanism underlying their appearance, like transient storage phenomena, just by rigorously solving the governing equation for the cross-sectional average concentration in the presence of nonuniform, asymmetrically located solute injections.

  16. A single-ensemble clutter rejection method based on the analytic geometry for ultrasound color flow imaging.

    Science.gov (United States)

    You, Wei; Wang, Yuanyuan

    2011-11-01

    In ultrasound color flow imaging (CFI), the single-ensemble eigen-based filters can reject clutter components using each slow-time ensemble individually. They have shown excellent spatial adaptability. This article proposes a novel clutter rejection method called the single-ensemble geometry filter (SGF), which is derived from an analytic geometry perspective. If the transmitted pulse number M equals two, the clutter component distribution on a two-dimensional (2-D) plane will be similar to a tilted ellipse. Therefore, the direction of the major axis of the ellipse can be used as the first principal component of the autocorrelation matrix estimated from multiple ensembles. Then the algorithm is generalized from 2-D to a higher dimensional space by using linear algebra representations of the ellipse. Comparisons have been made with the high-pass filter (HPF), the Hankel-singular value decomposition (SVD) filter and the recursive eigen-decomposition (RED) method using both simulated and human carotid data. Results show that compared with HPF and Hankel-SVD, the proposed filter causes less bias on the velocity estimation when the clutter velocity is close to that of the blood flow. On the other hand, the proposed filter does not need to update the autocorrelation matrix and can achieve better spatial adaptability than the RED.

  17. Critical flow-storm approach to total maximum daily load(TMDL) development: an analytical conceptual model

    Institute of Scientific and Technical Information of China (English)

    Harry X.ZHANG; Shaw L.YU

    2008-01-01

    One of the key challenges in the total max-imum daily load (TMDL) development process is how to define the critical condition for a receiving water-body. The main concern in using a continuous simu-lation approach is the absence of any guarantee that the most critical condition will be captured during the selected representative hydrologic period, given the scar-city of long-term continuous data. The objectives of this paper are to clearly address the critical condition in the TMDL development process and to compare continu-ous and evEnt-based approaches in defining critical con-dition during TMDL development for a waterbody impacted by both point and nonpoint source pollution. A practical, event-based critical flow-storm (CFS) approach was developed to explicitly addresses the crit-ical condition as a combination of a low stream flow and a storm event of a selected magnitude, both having cer-tain frequencies of occurrence. This paper illustrated the CFS concept and provided its theoretical basis using a derived analytical conceptual model. The CFS approach clearly defined a critical condition, obtained reasonable results and could be considered as an alternative method in TMDL development.

  18. Aeration Strategies To Mitigate Nitrous Oxide Emissions from Single-Stage Nitritation/Anammox Reactors

    DEFF Research Database (Denmark)

    Domingo Felez, Carlos; Mutlu, A. Gizem; Jensen, Marlene Mark;

    2014-01-01

    -stage nitritation/anammox were operated under different aeration strategies, gradually adjusted over six months. At constant but limiting oxygen loading, synthetic reject water was fed (0.75g-N/L.d) and high nitrogen removal efficiencies (83 +/- 5 and 88 +/- 2%) obtained. Dynamics of liquid phase nitrous (N2O......) and nitric oxide (NO) concentrations were monitored and N2O emissions calculated. Significant decreases in N2O emissions were obtained when the frequency of aeration was increased while maintaining a constant air flow rate (from >6 to 1.7% Delta N2O/Delta TN). However, no significant effect on the emissions...... was noted when the duration of aeration was increased while decreasing air flow rate (10.9 +/- 3.2% Delta N2O/Delta TN). The extant ammonium oxidation activity (mgNH(4)(+)-N/gVSS.min) positively correlated with the specific N2O production rate (mgN(2)O-N/gVSS.min) of the systems. Operating under conditions...

  19. Modeling of mixing in stirred bioreactors 4. mixing time for aerated bacteria, yeasts and fungus broths

    Directory of Open Access Journals (Sweden)

    Cascaval Dan

    2004-01-01

    Full Text Available The mixing time for bioreactors depends mainly on the rheoiogicai properties of the broths, the biomass concentration and morphology, mixing system characteristics and fermentation conditions. For quantifying the influence of these factors on the mixing efficiency for stirred bioreactors, aerated broths of bacteria (P. shermanii, yeasts (S. cerevisiae and fungi (P. chrysogenum, free mycelia and mycelial aggregates of different concentrations have been investigated using a laboratory bioreactor with a double turbine impeller. The experimental data indicated that the influence of the rotation speed, aeration rate and stirrer positions on the mixing intensity strongly differ from one system to another and must be correlated with the microorganism characteristics, namely: the biomass concentration and morphology. Moreover, compared with non-aerated broths, variations of the mixing time with the considered parameters are very different, due to the complex flow mechanism of gas-liquid dispersions. By means of the experimental data and using a multiregression analysis method some mathematical correlations for the mixing time of the general form: tm = a1*Cx2+a2*Cx+a3*IgVa+a4-N2+a5-N+a6/a7*L2+a8*L+a9 were established. The proposed equations offer good agreement with the experiments, the average deviation being ±6.7% - ±9.4 and are adequate for the flow regime Re < 25,000.

  20. Micro-aeration for hydrogen sulfide removal from biogas

    Science.gov (United States)

    Duangmanee, Thanapong

    The presence of sulfur compounds (e.g. protein, sulfate, thiosulfate, sulfite, etc.) in the feed stream generates highly corrosive and odorous hydrogen sulfide during anaerobic digestion. The high sulfide level in the biogas stream is not only poisonous to many novel metal catalysts employed in thermo-catalytic processes but also reduces the quality of methane to produce renewable energy. This study used an innovative, low-maintenance, low-cost biological sulfide removal technology to remove sulfides simultaneously from both gas and liquid phase. ORP (Oxidation-Reduction-Potential) was used as the controlling parameter to precisely regulate air injection to the sulfide oxidizing unit (SOU). The microaeration technique provided just enough oxygen to partially oxidize sulfides to elemental sulfur without inhibiting methanogenesis. The SOU was equipped with a diffuser at the bottom for the dispersion of sulfide-laden biogas and injected air throughout the column. The SOU can be operated as a standalone unit or coupled with an anaerobic digester to simultaneously remove sulfide from the biogas and effluent. The integrated system was capable of reducing hydrogen sulfide in biogas from 2,450 to less than 2 ppmV with minimal sulfate production at the highest available sulfide loading rate of 0.24 kg/m3-day. More than 98% of sulfide removed was recovered as elemental sulfur. However, the standalone SOU was able to operate at high hydrogen sulfide loading of 1.46 kg/m 3-day at inlet sulfide concentration of 3000 ppmV and reduce the off-gas hydrogen sulfide concentrations to less than 10 ppmV. The experiment also revealed that the ORP controlled aeration was sensitive enough to prevent oxygen overdosing (dampening effect) during unexpected surges of aeration. Using generalized linear regression, a model predicting output H2S concentration based on input H2S concentrations, SOU medium heights, and biogas flow rates, was derived. With 95% confidence, output H2S concentration

  1. An Analytical Method for Determining the Convection Heat Transfer Coefficient Between Flowing Fluid and Rock Fracture Walls

    Science.gov (United States)

    Bai, Bing; He, Yuanyuan; Hu, Shaobin; Li, Xiaochun

    2017-07-01

    The convective heat transfer coefficient (HTC) is a useful indicator that characterizes the convective heat transfer properties between flowing fluid and hot dry rock. An analytical method is developed to explore a more realistic formula for the HTC. First, a heat transfer model is described that can be used to determine the general expression of the HTC. As one of the novel elements, the new model can consider an arbitrary function of temperature distribution on the fracture wall along the direction of the rock radius. The resulting Dirichlet problem of the Laplace equation on a semi-disk is successfully solved with the Green's function method. Four specific formulas for the HTC are derived and compared by assuming the temperature distributions along the radius of the fracture wall to be zeroth-, first-, second-, and third-order polynomials. Comparative verification of the four specific formulas based on the test data shows that the formula A corresponding to the zeroth-order polynomial always predicts stable HTC values. At low flow rates, the four formulas predict similar values of HTC, but at higher flow rates, formulas B and D, respectively, corresponding to the first- and third-order polynomials, predict either too large or too small values of the HTC, while formula C, corresponding to the second-order polynomial, predicts relatively acceptable HTC values. However, we cannot tell which one is the more rational formula between formulas A and C due to the limited information measured. One of the clear advantages of formula C is that it can avoid the drawbacks of the discontinuity of temperature and the singular integral of HTC at the points (± R, 0). Further experimental work to measure the actual temperature distribution of water in the fracture will be of great value. It is also found that the absorbed heat of the fluid, Q, has a significant impact on the prediction results of the HTC. The temperatures at the inlet and the outlet used for Q should be

  2. Effect of aeration rate on composting of penicillin mycelial dreg.

    Science.gov (United States)

    Chen, Zhiqiang; Zhang, Shihua; Wen, Qinxue; Zheng, Jun

    2015-11-01

    Pilot scale experiments with forced aeration were conducted to estimate effects of aeration rates on the performance of composting penicillin mycelial dreg using sewage sludge as inoculation. Three aeration rates of 0.15, 0.50 and 0.90L/(min·kg) organic matter (OM) were examined. The principal physicochemical parameters were monitored during the 32day composting period. Results showed that the higher aeration rate of 0.90L/(min·kg) did not corresponded to a longer thermophilic duration and higher rates of OM degradation; but the lower aeration rate of 0.15L/(min·kg) did induce an accumulation of NH4(+)-N contents due to the inhibition of nitrification. On the other hand, aeration rate has little effect on degradation of penicillin. The results show that the longest phase of thermophilic temperatures≥55°C, the maximum NO3(-)-N content and seed germination, and the minimum C/N ratio were obtained with 0.50L/(min·kg) OM. Therefore, aeration rates of 0.50L/(min·kg) OM can be recommended for composting penicillin mycelial dreg.

  3. Interaction between afternoon aeration and tilapia stocking density

    Directory of Open Access Journals (Sweden)

    Francisco Roberto dos Santos Lima

    2016-01-01

    Full Text Available The present study aimed at determining the effects of the interaction between afternoon aeration and stocking density of Nile tilapia on variables of water and soil quality, growth performance and effluent quality. The experiment was a 3 x 2 factorial randomized block design, with three stocking densities (8, 12 and 16 fish per tank or 43.5, 65.3, and 87.0 g m-3 under two mechanical aeration regimes, absence (control; three replicates and afternoon aeration (four replicates. The afternoon aeration was carried out from 12.00 a.m. up to 18.00 p.m. from the 3rd week until the end of the experiment. Except for the 16-fish tanks, the lowest concentrations of total ammonia nitrogen were found in the tanks with higher density of fish provided with afternoon aeration. Nitrite concentrations were lower in the 8-fish aerated tanks. In intensive system, the afternoon aeration of the fish culture water is an efficient management of water quality to remove gaseous ammonia and nitrite from water, but it is not appropriate to remove hydrogen sulfide from water.

  4. Field-flow fractionation as analytical technique for the characterization of dry yeast: correlation with wine fermentation activity.

    Science.gov (United States)

    Sanz, Ramsés; Galceran, Ma Teresa; Puignou, Lluís

    2003-01-01

    Important oenological properties of wine depend on the winemaking yeast used in the fermentation process. There is considerable controversy about the quality of yeast, and a simple and cheap analytical methodology for quality control of yeast is needed. Gravitational field flow fractionation (GFFF) was used to characterize several commercial active dry wine yeasts from Saccharomyces cerevisiae and Saccharomyces bayanus and to assess the quality of the raw material before use. Laboratory-scale fermentations were performed using two different S. cerevisiae strains as inocula, and GFFF was used to follow the behavior of yeast cells during alcoholic fermentation. The viable/nonviable cell ratio was obtained by flow cytometry (FC) using propidium iodide as fluorescent dye. In each experiment, the amount of dry wine yeast to be used was calculated in order to provide the same quantity of viable cells. Kinetic studies of the fermentation process were performed controlling the density of the must, from 1.071 to 0.989 (20/20 density), and the total residual sugars, from 170 to 3 g/L. During the wine fermentation process, differences in the peak profiles obtained by GFFF between the two types of commercial yeasts that can be related with the unlike cell growth were observed. Moreover, the strains showed different fermentation kinetic profiles that could be correlated with the corresponding fractograms monitored by GFFF. These results allow optimism that sedimentation FFF techniques could be successfully used for quality assessment of the raw material and to predict yeast behavior during yeast-based bioprocesses such as wine production.

  5. Unsteady fluid flow in a slightly curved pipe: A comparative study of a matched asymptotic expansions solution with a single analytical solution

    Science.gov (United States)

    Messaris, Gerasimos A. T.; Hadjinicolaou, Maria; Karahalios, George T.

    2016-08-01

    The present work is motivated by the fact that blood flow in the aorta and the main arteries is governed by large finite values of the Womersley number α and for such values of α there is not any analytical solution in the literature. The existing numerical solutions, although accurate, give limited information about the factors that affect the flow, whereas an analytical approach has an advantage in that it can provide physical insight to the flow mechanism. Having this in mind, we seek analytical solution to the equations of the fluid flow driven by a sinusoidal pressure gradient in a slightly curved pipe of circular cross section when the Womersley number varies from small finite to infinite values. Initially the equations of motion are expanded in terms of the curvature ratio δ and the resulting linearized equations are solved analytically in two ways. In the first, we match the solution for the main core to that for the Stokes boundary layer. This solution is valid for very large values of α. In the second, we derive a straightforward single solution valid to the entire flow region and for 8 ≤ α stresses and is compared to the analogous forms presented in other studies. The two solutions give identical results to each other regarding the axial flow but differ in the secondary flow and the circumferential wall stress, due to the approximations employed in the matched asymptotic expansion process. The results on the stream function from the second solution are in agreement with analogous results from other numerical solutions. The second solution predicts that the atherosclerotic plaques may develop in any location around the cross section of the aortic wall unlike to the prescribed locations predicted by the first solution. In addition, it gives circumferential wall stresses augmented by approximately 100% with respect to the matched asymptotic expansions, a factor that may contribute jointly with other pathological factors to the faster aging of the

  6. Multi-parameter flow cytometry as a process analytical technology (PAT) approach for the assessment of bacterial ghost production.

    Science.gov (United States)

    Langemann, Timo; Mayr, Ulrike Beate; Meitz, Andrea; Lubitz, Werner; Herwig, Christoph

    2016-01-01

    Flow cytometry (FCM) is a tool for the analysis of single-cell properties in a cell suspension. In this contribution, we present an improved FCM method for the assessment of E-lysis in Enterobacteriaceae. The result of the E-lysis process is empty bacterial envelopes-called bacterial ghosts (BGs)-that constitute potential products in the pharmaceutical field. BGs have reduced light scattering properties when compared with intact cells. In combination with viability information obtained from staining samples with the membrane potential-sensitive fluorescent dye bis-(1,3-dibutylarbituric acid) trimethine oxonol (DiBAC4(3)), the presented method allows to differentiate between populations of viable cells, dead cells, and BGs. Using a second fluorescent dye RH414 as a membrane marker, non-cellular background was excluded from the data which greatly improved the quality of the results. Using true volumetric absolute counting, the FCM data correlated well with cell count data obtained from colony-forming units (CFU) for viable populations. Applicability of the method to several Enterobacteriaceae (different Escherichia coli strains, Salmonella typhimurium, Shigella flexneri 2a) could be shown. The method was validated as a resilient process analytical technology (PAT) tool for the assessment of E-lysis and for particle counting during 20-l batch processes for the production of Escherichia coli Nissle 1917 BGs.

  7. Heat Generation/Absorption Effects in a Boundary Layer Stretched Flow of Maxwell Nanofluid: Analytic and Numeric Solutions.

    Directory of Open Access Journals (Sweden)

    Muhammad Awais

    Full Text Available Analysis has been done to investigate the heat generation/absorption effects in a steady flow of non-Newtonian nanofluid over a surface which is stretching linearly in its own plane. An upper convected Maxwell model (UCM has been utilized as the non-Newtonian fluid model in view of the fact that it can predict relaxation time phenomenon which the Newtonian model cannot. Behavior of the relaxations phenomenon has been presented in terms of Deborah number. Transport phenomenon with convective cooling process has been analyzed. Brownian motion "Db" and thermophoresis effects "Dt" occur in the transport equations. The momentum, energy and nanoparticle concentration profiles are examined with respect to the involved rheological parameters namely the Deborah number, source/sink parameter, the Brownian motion parameters, thermophoresis parameter and Biot number. Both numerical and analytic solutions are presented and found in nice agreement. Comparison with the published data is also made to ensure the validity. Stream lines for Maxwell and Newtonian fluid models are presented in the analysis.

  8. Heat Generation/Absorption Effects in a Boundary Layer Stretched Flow of Maxwell Nanofluid: Analytic and Numeric Solutions.

    Science.gov (United States)

    Awais, Muhammad; Hayat, Tasawar; Irum, Sania; Alsaedi, Ahmed

    2015-01-01

    Analysis has been done to investigate the heat generation/absorption effects in a steady flow of non-Newtonian nanofluid over a surface which is stretching linearly in its own plane. An upper convected Maxwell model (UCM) has been utilized as the non-Newtonian fluid model in view of the fact that it can predict relaxation time phenomenon which the Newtonian model cannot. Behavior of the relaxations phenomenon has been presented in terms of Deborah number. Transport phenomenon with convective cooling process has been analyzed. Brownian motion "Db" and thermophoresis effects "Dt" occur in the transport equations. The momentum, energy and nanoparticle concentration profiles are examined with respect to the involved rheological parameters namely the Deborah number, source/sink parameter, the Brownian motion parameters, thermophoresis parameter and Biot number. Both numerical and analytic solutions are presented and found in nice agreement. Comparison with the published data is also made to ensure the validity. Stream lines for Maxwell and Newtonian fluid models are presented in the analysis.

  9. Toward a new modelling of gas flows in a semi-analytical model of galaxy formation and evolution

    CERN Document Server

    Cousin, Morgane; Bethermin, Matthieu; Guiderdoni, Bruno

    2014-01-01

    We present an extended version of the semi-analytical model, GalICS. As its predecessor, eGalICS applies a post-treatment of the baryonic physics on pre-computed dark-matter merger trees extracted from a N-body simulation. We review all the mechanisms that affect, at a given time, the formation and evolution of a galaxy in its host dark-matter halo. We mainly focus on the gas cycle, from the smooth cosmological accretion to feedback processes. To follow with a high accuracy this cycle we introduce some novel prescriptions: i) a smooth baryonic accretion with two phases: a cold mode and a hot mode built on the continuous dark-matter accretion. In parallel to this smooth accretion we implement the standard photoionisation modelling to reduce the input gas flow on the smallest structures. ii) a complete monitoring of the hot gas phase. We compute the evolution of the core density, the mean temperature and the instantaneous escape fraction of the hot atmosphere by considering that the hot gas is in hydrostatic eq...

  10. Analytic expressions for first order correction to inviscid unsteady forces due to surrounding particles in a multiphase flow

    Science.gov (United States)

    Annamalai, Subramanian; Balachandar, S.; Mehta, Yash

    2015-11-01

    The various inviscid and viscous forces experienced by an isolated spherical particle situated in a compressible fluid have been widely studied in literature and are well established. Further, these force expressions are used even in the context of particulate (multiphase) flows with appropriate empirical correction factors that depend on local particle volume fraction. Such approach can capture the mean effect of the neighboring particles, but fails to capture the effect of the precise arrangement of the neighborhood of particles. To capture this inherent dependence of force on local particle arrangement a more accurate evaluation of the drag forces proves necessary. Towards this end, we consider an acoustic wave of a given frequency to impinge on a sphere. Scattering due to this particle (reference) is computed and termed ``scattering coefficients.'' The effect of the reference particle on another particle in its vicinity, is analytically computed via the above mentioned ``scattering coefficients'' and as a function of distance between particles. In this study, we consider only the first-order scattering effect. Moreover, this theory is extended to compressible spheres and used to compute the pressure in the interior of the sphere and to shock interaction over an array of spheres. We would like to thank the center for compressible multiphase turbulence (CCMT) and acknowledge support from the U.S. Department of Energy, National Nuclear Security Administration, Advanced Simulation and Computing Program.

  11. Evaluation of aerated biofilter systems for microbial methane oxidation of poor landfill gas.

    Science.gov (United States)

    Haubrichs, R; Widmann, R

    2006-01-01

    In the long-term, landfills are producing landfill gas (LFG) with low calorific values. Therefore, the utilization of LFG in combined heat and power plants (CHP) is limited to a certain period of time. A feasible method for LFG treatment is microbial CH(4) oxidation. Different materials were tested in actively aerated lab-scale bio-filter systems with a volume of 0.167 m(3). The required oxygen for the microbial CH(4) oxidation was provided through perforated probes, which distributed ambient air into the filter material. Three air input levels were installed along the height of the filter, each of them adjusted to a particular flow rate. During the tests, stable degradation rates of around 28 g/(m(3) h) in a fine-grained compost material were observed at a CH(4) inlet concentration of 30% over a period of 148 days. Compared with passive (not aerated) tests, the CH(4) oxidation rate increased by a factor of 5.5. Therefore, the enhancement of active aeration on the microbial CH(4) oxidation was confirmed. At a O(2)/CH(4) ratio of 2.5, nearly 100% of the CH(4) load was decomposed. By lowering the ratio from 2.5 to 2, the efficiency fell to values from 88% to 92%. By varying the distribution to the three air input levels, the CH(4) oxidation process was spread more evenly over the filter volume.

  12. Biogas purification using membrane micro-aeration: A mass transfer analysis

    Directory of Open Access Journals (Sweden)

    Wathsala Perera, Deshai Botheju, Rune Bakke

    2014-01-01

    Full Text Available When sulfur containing organic feedstocks undergo anaerobic digestion, sulfides are formed due to the biological activities of sulfur reducing bacteria. Presence of hydrogen sulfide (H2S negatively affects the usage of biogas and needs to be reduced to levels that depend on the intended biogas application. Conversion of sulfide to its oxidized forms can be carried out by aerobic chemolithotrophic bacteria consuming oxygen as the electron acceptor. Membrane micro-aeration is a recently developed reliable method of safely supplying oxygen into anaerobic digesters. In this study, mass transfer models are developed to represent diffusion and back diffusion of gases through tubular polydimethylsiloxane (PDMS membranes. The models are utilized to determine the required membrane area and length in order to supply the stoichiometric amount of oxygen for biologically oxidizing a given amount of sulfide feed into elemental sulfur. Penetration of oxygen and nitrogen into the digester and transfer of methane, carbon dioxide and hydrogen sulfide back into the membrane tube are analyzed using these mass transfer models. Circulating air or aerated water inside the membrane tube is considered as two alternatives for supplying micro-aeration to the digester. Literature digester performance and sulfide data are used for example calculations. The required membrane length depends on circulating water flow rates and dissolved oxygen concentrations when water is used inside the membrane. A considerable fraction of CO2 can also be removed from the biogas in this case. Circulating air inside the membrane is, however, more promising solution as it requires much less membrane area and thereby also causes insignificant methane loss. The proposed membrane micro-aeration technique cuts N2 biogas dilution in half compared to direct air purging for in-situ sulfide oxidation.

  13. Analytical Investigation by Using the Two-fluid-model to Study the Interfacial Behavior of Air-water Horizontal Stratified Flow

    CERN Document Server

    Kuntoro, Hadiyan Yusuf; Indarto,

    2015-01-01

    In the chemical, petroleum and nuclear industries, pipelines are often used to transport fluids from one process site to another one. The understanding of the fluids behavior inside the pipelines is the most important consideration for the engineers and scientists. From the previous studies, there are several two-phase flow patterns in horizontal pipe. One of them is stratified flow pattern, which is characterized by the liquid flowing along the bottom of the pipe and the gas moving above it cocurrently. Another flow patterns are slug and plug flow patterns. This kind of flow triggers the damage in pipelines, such as corrosion, abrasion, and blasting pipe. Therefore, slug and plug flow patterns are undesirable in pipelines, and the flow is maintained at the stratified flow condition for safety reason. In this paper, the analytical-based study on the experiment of the stratified flow pattern in a 26 mm i.d. horizontal pipe is presented. The experiment is performed to develop a high quality database of the stra...

  14. INVESTIGATIONS INTO BIOFOULING PHENOMENA IN FINE PORE AERATION DEVICES

    Science.gov (United States)

    Microbiologically-based procedures were used to describe biofouling phenomena on fine pore aeration devices and to determine whether biofilm characteristics could be related to diffuser process performance parameters. Fine pore diffusers were obtained from five municipal wastewa...

  15. The impact of aeration on potato (Solanum tuberosum L.) minituber ...

    African Journals Online (AJOL)

    aghomotsegin

    2015-03-18

    Mar 18, 2015 ... for minituber production encounters challenges worldwide .... Dissolved oxygen in the media; comparison of different aeration levels (Control = 0, Low = 12.5,. Moderate = 25 ...... Relations between specific gravity, dry matter.

  16. Generating CO(2)-credits through landfill in situ aeration.

    Science.gov (United States)

    Ritzkowski, M; Stegmann, R

    2010-04-01

    Landfills are some of the major anthropogenic sources of methane emissions worldwide. The installation and operation of gas extraction systems for many landfills in Europe and the US, often including technical installations for energy recovery, significantly reduced these emissions during the last decades. Residual landfill gas, however, is still continuously produced after the energy recovery became economically unattractive, thus resulting in ongoing methane emissions for many years. By landfill in situ aeration these methane emissions can be widely avoided both, during the aeration process as well as in the subsequent aftercare period. Based on model calculations and online monitoring data the amount of avoided CO(2-eq). can be determined. For an in situ aerated landfill in northern Germany, acting as a case study, 83-95% (depending on the kind and quality of top cover) of the greenhouse gas emission potential could be reduced under strictly controlled conditions. Recently the United Nations Framework Convention on Climate Change (UNFCCC) has approved a new methodology on the "Avoidance of landfill gas emissions by in situ aeration of landfills" (UNFCCC, 2009). Based on this methodology landfill aeration projects might be considered for generation of Certified Emission Reductions (CERs) in the course of CDM projects. This paper contributes towards an evaluation of the potential of landfill aeration for methane emissions reduction. Copyright 2009 Elsevier Ltd. All rights reserved.

  17. Effect of aeration on fast gas pressure tests

    Institute of Scientific and Technical Information of China (English)

    CHEN Yu-jia; JIANG Cheng-lin; LI Xiao-wei; TANG Jun; WANG Chen; YANG Fei-long; WANG Fa-kai; ZHANG Chao-jie; DENG Shu-hua

    2009-01-01

    Given the problem of the long time required for testing gas pressure, we propose a fast-test method in which we used a technique of fast borehole sealing and air replenishing. Based on the characteristics of gas emission from boreholes to be tested, we built a theoretical model for calculating parameters during the process of increasing natural pressure and aeration. Using this model, we investigated the effect of different aeration conditions on velocity of pressure tests. The result shows that: 1) aerating air into boreholes can speed up gas pressure tests and 2) the more similar the pressure of the aerated air to the original gas pressure, the smaller the gas volume absorbed by coal and the shorter the time needed in pressure test. A case study in the Lu'an mining area shows that the time needed for gas pressure test is only 4 h using our method of aeration and 29 h under conditions of increasing natural pressure, saving time by 86.2%. This case study also indicates that, by using the aeration method, only one hour is needed for gas pressure to reach a stable state, which breaks the record of the shortest time needed for gas pressure tests in China.

  18. Analytical study of parameters affecting entropy generation of nanofluid turbulent flow in channel and micro-channel

    Directory of Open Access Journals (Sweden)

    Sheikhzadeh Ghanbarali

    2016-01-01

    Full Text Available In this study, thermo-physical and geometrical parameters affecting entropy generation of nanofluid turbulent flow such as the volume fraction, Reynolds number and diameter of the channel and micro-channel with circular cross section under constant flux are examined analytically. Water is used as a base fluid of nanofluid with nanoparticles of Ag, Cu, CuO and TiO2. The study is conducted for Reynolds numbers of 20000, 40000 and 100000, volume fractions of 0, 0.01, 0.02, 0.03 and 0.04, channel diameters of 2, 4, 6 and 8 cm and micro-channel diameters of 20, 40, 60 and 80 micrometers. Based on the results, the most of the generated entropy in channel is due to heat transfer, and also, with increasing the diameter of the channel, Bejan number increases. The contribution of entropy generation due to heat transfer in the micro-channel is very poor and the major contribution of entropy generation is due to friction. The maximum amount of entropy generation in channel belongs to nanofluids with Ag, Cu, CuO and TiO2 nanoparticles, respectively, while in the micro-channel this behavior is reversed; and the minimum entropy generation happens in nanofluids with Ag, Cu, CuO and TiO2 nanoparticles, respectively. In channel and micro-channel, for all nanofluids except for the water-TiO2, with increasing volume fraction of nanoparticles, the entropy generation decreases. In channel and micro-channel, the total entropy generation increases as Reynolds number augments.

  19. Gradually-varied open-channel flow profiles normalized by critical depth and analytically solved by using Gaussian hypergeometric functions

    Directory of Open Access Journals (Sweden)

    C. D. Jan

    2012-10-01

    Full Text Available The equation of one-dimensional gradually-varied flow (GVF in sustaining and non-sustaining open channels is normalized using the critical depth, hc, and then analytically solved by the direct integration method with the use of the Gaussian hypergeometric function (GHF. The GHF-based solution so obtained from the hc-based dimensionless GVF equation is more useful and versatile than its counterpart from the GVF equation normalized by the normal depth, hn, because the GHF-based solutions of the hc-based dimensionless GVF equation for the mild (M and adverse (A profiles can asymptotically reduce to the hc-based dimensionless horizontal (H profiles as hc/hn → 0. An in-depth analysis of the hc-based dimensionless profiles expressed in terms of the GHF for GVF in sustaining and adverse wide channels has been conducted to discuss the effects of hc/hn and the hydraulic exponent N on the profiles This paper has laid the foundation to compute at one sweep the hc-based dimensionless GVF profiles in a series of sustaining and adverse channels, which have horizontal slopes sandwiched in between them, by using the GHF-based solutions.

  20. Flow cytometry for feline lymphoma: a retrospective study about pre-analytical factors possibly affecting the quality of samples

    Directory of Open Access Journals (Sweden)

    Serena Bernardi

    2017-05-01

    Full Text Available Introduction Flow cytometry (FC is an increasingly required technique on which veterinary oncologists rely to have an accurate, fast, minimally invasive lymphoma or leukemia diagnosis. FC has been studied and applied with great results in canine oncology, whereas in feline oncology the use of this technique is still to be experienced. This is mainly due to a supposed discomfort in sampling, because of the high prevalence of intra-abdominal lymphomas. The purpose of the present study is to investigate whether any pre-analytical factor might affect the quality of suspected feline lymphoma samples for FC analysis. Methods 97 consecutive samples of suspected feline lymphoma were retrospectively selected from the authors’ institution FC database. The referring veterinarians were recalled and interrogated about several different variables, including signalling, features of the lesion, features of the sampling procedure and the experience of veterinarians performing the sampling. Statistical analyses were performed to assess the possible influence of these variables on the cellularity of the samples and the likelihood of being finally processed for FC. Results None of the investigated variables significantly influenced the quality of the submitted samples, but the needle size, with 21G needles providing the highest cellularity (Table 1. Notably, the samples quality did not vary between peripheral and intra-abdominal lesions. Sample cellularity alone influenced the likelihood of being processed. About a half of the cats required pharmacological restraint. Side effects were reported in one case only (transient swelling after peripheral lymph node sampling. Conclusions FC can be safely applied to cases of suspected feline lymphomas, even for intra-abdominal lesions. 21G needle should be preferred for sampling. This study provides the bases for the spread of this minimally invasive, fast and cost-effective technique in feline medicine.

  1. Study on efficiency of refractory linear alkyl-benzene sulfonates(LAS) removal from synthetic detergent wastewater by novel up-flow biological aerated filter%新型UBAF处理合成洗涤剂废水中降解LAS的效能研究

    Institute of Scientific and Technical Information of China (English)

    纪桂霞; 周步轩; 张欢; 刘弦

    2012-01-01

    通过在清水区悬挂生物绳软填料的上向流曝气生物滤池处理合成洗涤剂废水的试验,研究了水力负荷、气水比、污染负荷、滤层高度及溶解氧等对LAS处理效能的影响.结果表明:水力负荷、气水比及滤层厚度是新型UBAF处理效能的主要影响因素,进水污染负荷对LAS处理效能的影响不显著.废水LAS浓度与流经的滤层厚度存在很好的指数关系:Ch=C0ekh.新型UBAF的挂膜性能好,启动速度快,对COD、LAS的处理效能有一定提高.在水力负荷1.1 m3/(m2·h),气水比3∶1~4∶1的运行条件下,对典型合成洗涤剂废水中的LAS去除率达80%以上,处理水的LAS指标达到排放标准.%To improve the efficiency of up - flow biological aerated filter, fixed bio - cord in clarifying region was proposed and the novel system named NUBAF was applied on laboratory scale. Through study the effects of hydraulic loading, ratio of air to liquid, pollution load, media height and DO on linear alkyl - benzene sulfonates ( LAS) treatment performance using this new process and the results indicated that the hydraulic loading, ratio of air to liquid and media height were the main factors to the NUBAF performance , but the effect of the pollution load on the NUBAF performance was unremarkable. The removal efficiency of LAS could be up to 80 % under the optimal conditions; the hydraulic loading of 1. 1 mV (m2 ? H) , ratio of air to liquid of 3= 1 ~4: 1 (based on 3.3 mV (m2 ? H) :1. 1 m3/ (m2 ? H) ) , besides, there was an exponential relationship between the concentration of LAS and media height expressed as Ch = C0ekh. After treated by NUBAF, effluent was greatly improved to reach the discharge standards of China.

  2. 高速给水曝气生物滤池应用于大型自来水厂的预处理%Application of High-Rate Up-Flow Biological Aerated Filter to Pretreatment for Large-Scale Waterworks

    Institute of Scientific and Technical Information of China (English)

    陆少鸣; 李芳; 李少文

    2012-01-01

    In order to avoid the micro-pollution of drinking water source due to ammonia nitrogen (NH3-N) and or-ganics, for the first time, a waterworks in Guangzhou city adopted the high-rate up-flow biological aerated filter ( HUBAF) with a flow rate of 735 thousand ton per day as a pretreatment process. In the first three months after the stable operation, the NH3-N content and CODMn in raw water respectively reached 0. 44 ~ 2. 22 mg/L and 1. 84 ~ 6. 06 mg/L, and those in the pretreatment effluent were respectively below 0.5mg/L and 2. Omg/L. Moreover, the iron and manganese contents in the raw water were respectively up to 1. 16 and 0.22 mg/L, while those in the waterworks effluent were respectively 0. 05 and 0. 03 mg/L. Due to the large-particle ceramic filter media combined with fluid-bed technology, the average removal of turbidity was only about 2.5 NTU and the head loss was steadily below 1.0m. HUBAF adopts an air-water-combined backwashing system with up-and-down flow, which keeps the change of head loss within 0.1m and makes it possible to share a common aeration system in the filter. The application of HUBAF demonstrates that, as compared with the biological pretreatment technologies that have been put into application, such as the elastic packing-contact oxidation technology and the suspended-ball fluidized technology, HUBAF possesses stronger resistance to impact loading, higher NH3-N nitration rate and better removal of iron and manganese, and that the "HUBAF-conventional treatment" combined system is of a organics removal similar to that of the "O3-BAC" advanced process.%为克服氨氮和有机物对饮用水源的微污染,广州市某水厂首次采用了高速给水曝气生物滤池(HUBAF)生物预处理新工艺,处理规模为73.5万m3/d.工程投产稳定运行后,初期3个月原水氨氮和CODMn分别为0.44~2.22 mg/L和1.84~6.06 mg/L,预处理出水分别小于0.5 mg/L和2.0mg/L;原水的铁和锰最高达1.16 mg/L和0.22 mg

  3. A new step aeration approach towards the improvement of nitrogen removal in a full scale Carrousel oxidation ditch.

    Science.gov (United States)

    Jin, Pengkang; Wang, Xianbao; Wang, Xiaochang; Ngo, Huu Hao; Jin, Xin

    2015-12-01

    Two aeration modes, step aeration and point aeration, were used in a full-scale Carrousel oxidation ditch with microporous aeration. The nitrogen removal performance and mechanism were analyzed. With the same total aeration input, both aeration modes demonstrated good nitrification outcomes with the average efficiency in removing NH4(+)-N of more than 98%. However, the average removal efficiencies for total nitrogen were 89.3% and 77.6% under step aeration and point aeration, respectively. The results indicated that an extended aerobic zone followed the aeration zones could affect the proportion of anoxic and oxic zones. The step aeration with larger anoxic zones indicated better TN removal efficiency. More importantly, step aeration provided the suitable environment for both nitrifiers and denitrifiers. The diversity and relative abundance of denitrifying bacteria under the step aeration (1.55%) was higher than that under the point aeration (1.12%), which resulted in an overall higher TN removal efficiency.

  4. Mathematical model analysis on the enhancement of aeration efficiency using ladder-type flat membrane module forms in the Submerged Membrane Bio-reactor(SMBR)

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    The cross-flow shearing action produced from the inferior aeration in the Submerged Membrane Bio-reactor(SMBR) is an effective way to further improve anti-fouling effects of membrane modules.Based on the widely-applied vertical structure of flat membrane modules,improvements are made that ladder-type flat membrane structure is designed with a certain inclined angle θ so that the cross-flow velocity of bubble near the membrane surface can be held,and the intensity and times of elastic colli-sion between bubbles and membrane surface can be increased.This can improve scouring action of membrane surface on aeration and reduce energy consumption of strong aeration in SMBR.By de-ducing and improving the mathematics model of collision between bubble and vertical flat put forward by Vries,the relatively suitable incline angle θ under certain aeration place and in certain size rang of bubble can be obtained with the computer iterative calculation technology.Finally,for many groups of ladder-type flat membrane in parallel placement in the practical application of SMBR,some sugges-tions are offered:the interval distance of membrane modules is 8―15 mm,and aeration should be op-erated at 5―7 mm among membrane modules,and the optimal design angle of trapeziform membrane is 1.7°―2.5°.

  5. Mathematical model analysis on the enhancement of aeration efficiency using ladder-type flat membrane module forms in the Submerged Membrane Bio-reactor (SMBR)

    Institute of Scientific and Technical Information of China (English)

    LI Bo; YE MaoSheng; YANG FengLin; MA Hui

    2009-01-01

    The cross-flow shearing action produced from the inferior aeration in the Submerged Membrane Bio-reactor (SMBR) Is an effective way to further improve anti-fouling effects of membrane modules.Based on the widely-applied vertical structure of flat membrane modules, improvements are made that ladder-type flat membrane structure is designed with a certain inclined angle θ so that the cross-flow velocity of bubble near the membrane surface can be held, and the intensity and times of elastic colli-sion between bubbles and membrane surface can be increased. This can improve scouring action ofmembrane surface on aeration and reduce energy consumption of strong aeration in SMBR. By de-ducing and improving the mathematics model of collision between bubble and vertical flat put forward by Vries, the relatively suitable Incline angle θ under certain aeration place and in certain size rang ofbubble can be obtained with the computer iterative calculation technology. Finally, for many groups of ladder-type flat membrane in parallel placement in the practical application of SMBR, some sugges-tions are offered: the interval distance of membrane modules is 8--15 mm, and aeration should be op-erated at 5--7 mm among membrane modules, and the optimal design angle of trapeziform membrane is 1.7°--2.5°.

  6. Removal of arsenic from contaminated groundwater with application of iron electrodissolution, aeration and sand filtration

    DEFF Research Database (Denmark)

    Kowalski, Krysztof; Arturi, Kasia; Søgaard, Erik Gydesen

    2014-01-01

    The results from a new water treatment system for arsenic removal are presented. The technology is based on the employment of an electrolytic iron dissolution and efficient aeration procedure prior to sand filtration. The treatment was introduced and investigated in a pilot scale plant and full...... scale waterworks. The pilot scale results showed a possibility for an efficient arsenic removal from spiked solutions (with As in the range of 50–85 μg/L) depending on the process conditions (flow and applied current). In the waterworks where the system was implemented for a period of 14 months...

  7. Analytical solutions for the temperature field in a 2D incompressible inviscid flow through a channel with walls of solid fuel

    Directory of Open Access Journals (Sweden)

    Sorin BERBENTE

    2011-12-01

    Full Text Available A gas (oxidizer flows between two parallel walls of solid fuel. A combustion is initiated: the solid fuel is vaporized and a diffusive flame occurs. The hot combustion products are submitted both to thermal diffusion and convection. Analytical solutions can be obtained both for the velocity and temperature distributions by considering an equivalent mean temperature where the density and the thermal conductivity are evaluated. The main effects of heat transfer are due to heat convection at the flame. Because the detailed mechanism of the diffusion flame is not introduced the reference chemical reaction is the combustion of premixed fuel with oxidizer in excess. In exchange the analytical solution is used to define an ideal quasi-uniform combustion that could be realized by an n adequate control. The given analytical closed solutions prove themselves flexible enough to adjust the main data of some existing experiments and to suggest new approaches to the problem.

  8. Continuous flow analytical microsystems based on low-temperature co-fired ceramic technology. Integrated potentiometric detection based on solvent polymeric ion-selective electrodes.

    Science.gov (United States)

    Ibanez-Garcia, Nuria; Mercader, Manel Bautista; Mendes da Rocha, Zaira; Seabra, Carlos Antonio; Góngora-Rubio, Mario Ricardo; Chamarro, Julian Alonso

    2006-05-01

    In this paper, the low-temperature co-fired ceramics (LTCC) technology, which has been commonly used for electronic applications, is presented as a useful alternative to construct continuous flow analytical microsystems. This technology enables not only the fabrication of complex three-dimensional structures rapidly and at a realistic cost but also the integration of the elements needed to carry out a whole analytical process, such as pretreatment steps, mixers, and detection systems. In this work, a simple and general procedure for the integration of ion-selective electrodes based on liquid ion exchanger is proposed and illustrated by using ammonium- and nitrate-selective membranes. Additionally, a screen-printed reference electrode was easily incorporated into the microfluidic LTCC structure allowing a complete on-chip integration of the potentiometric detection. Analytical features of the proposed systems are presented.

  9. Three-dimensional benchmark for variable-density flow and transport simulation: matching semi-analytic stability modes for steady unstable convection in an inclined porous box

    Science.gov (United States)

    Voss, Clifford I.; Simmons, Craig T.; Robinson, Neville I.

    2010-01-01

    This benchmark for three-dimensional (3D) numerical simulators of variable-density groundwater flow and solute or energy transport consists of matching simulation results with the semi-analytical solution for the transition from one steady-state convective mode to another in a porous box. Previous experimental and analytical studies of natural convective flow in an inclined porous layer have shown that there are a variety of convective modes possible depending on system parameters, geometry and inclination. In particular, there is a well-defined transition from the helicoidal mode consisting of downslope longitudinal rolls superimposed upon an upslope unicellular roll to a mode consisting of purely an upslope unicellular roll. Three-dimensional benchmarks for variable-density simulators are currently (2009) lacking and comparison of simulation results with this transition locus provides an unambiguous means to test the ability of such simulators to represent steady-state unstable 3D variable-density physics.

  10. On-line gaseous formaldehyde detection by a microfluidic analytical method based on simultaneous uptake and derivatization in a temperature controlled annular flow.

    Science.gov (United States)

    Guglielmino, Maud; Bernhardt, Pierre; Trocquet, Claire; Serra, Christophe A; Le Calvé, Stéphane

    2017-09-01

    This paper is focused on the improvement of a microfluidic analytical method for the detection of low airborne formaldehyde concentrations, based on only two distinct steps permitting to reduce the response time and to improve the compactness of the device. First, gaseous formaldehyde is trapped into an acetylacetone solution at 65°C through an annular liquid/gas flow and reacts immediately to form 3,5-Diacetyl-1,4-dihydrolutidine which is then quantified by colorimetry using a liquid core waveguide (LCW). To obtain an annular flow, 3 different hydrophilic silica capillaries of 320, 450 and 530µm ID were tested and the corresponding phase diagrams were obtained in the ranges of liquid and gas flows of 5-35µLmin(-1) and 5-35mLmin(-1) respectively. Finally, the analytical performances were determined using the lowest flow values of 5µLmin(-1) and 5NmLmin(-1), ensuring an annular flow and increasing the microdevice autonomy. If the uptake yield of gaseous formaldehyde into the solution was close to 100%, only the 530µm ID capillary permits to obtain a reaction time long enough for a full conversion of formaldehyde into 3,5-Diacetyl-1,4-dihydrolutidine. With a LCW pathlength of 5cm, the microdevice response was perfectly linear in the range 0-154µgm(-3) with a detection limit of 1.8µgm(-3). Copyright © 2017 Elsevier B.V. All rights reserved.

  11. [Research of controlling condition for aeration stabilization pond dealing with sanitary waste of countryside].

    Science.gov (United States)

    Li, Huai-Zheng; Yao, Shu-Jun; Xu, Zu-Xin; Chen, Wei-Bing

    2012-10-01

    According to research of some problems, such as the hydraulic detention time that aeration stabilization pond deals with sanitary waste of countryside, dissolved oxygen in pond during the process of aeration, the concentration distribution of sludge and different aeration periods affecting on the treatment efficiency, we can acquire good treatment efficiency and energy consumption of economy. The results indicate that under the aeration stabilization pond of this experiment, 4 d is the best hydraulic detention time with this aeration stabilization pond. Time of the discontinuous running aeration should be greater than 15 min. The concentration distribution of sludge can reach equilibrium at each point of aeration stabilization pond between 2 min and 10 min. The best aeration period of dislodging the pollutant is 0.5 h aeration/1.0 h cut-off.

  12. Analytical Solutions of Heat Transfer and Film Thickness with Slip Condition Effect in Thin-Film Evaporation for Two-Phase Flow in Microchannel

    Directory of Open Access Journals (Sweden)

    Ahmed Jassim Shkarah

    2015-01-01

    Full Text Available Physical and mathematical model has been developed to predict the two-phase flow and heat transfer in a microchannel with evaporative heat transfer. Sample solutions to the model were obtained for both analytical analysis and numerical analysis. It is assumed that the capillary pressure is neglected (Morris, 2003. Results are provided for liquid film thickness, total heat flux, and evaporating heat flux distribution. In addition to the sample calculations that were used to illustrate the transport characteristics, computations based on the current model were performed to generate results for comparisons with the analytical results of Wang et al. (2008 and Wayner Jr. et al. (1976. The calculated results from the current model match closely with those of analytical results of Wang et al. (2008 and Wayner Jr. et al. (1976. This work will lead to a better understanding of heat transfer and fluid flow occurring in the evaporating film region and develop an analytical equation for evaporating liquid film thickness.

  13. Seasonal variations and aeration effects on water quality improvements and physiological responses of Nymphaea tetragona Georgi.

    Science.gov (United States)

    Lu, Xiao-Ming; Lu, Peng-Zhen; Huang, Min-Sheng; Dai, Ling-Peng

    2013-01-01

    Seasonal variations and aeration effects on water quality improvements and the physiological responses of Nymphaea tetragona Georgi were investigated with mesocosm experiments. Plants were hydroponically cultivated in six purifying tanks (aerated, non-aerated) and the characteristics of the plants were measured. Water quality improvements in purifying tanks were evaluated by comparing to the control tanks. The results showed that continuous aeration affected the plant morphology and physiology. The lengths of the roots, petioles and leaf limbs in aeration conditions were shorter than in non-aeration conditions. Chlorophyll and soluble protein contents of the leaf limbs in aerated tanks decreased, while peroxidase and catalase activities of roots tissues increased. In spring and summer, effects of aeration on the plants were less than in autumn. Total nitrogen (TN) and ammonia nitrogen (NH4(+)-N) in aerated tanks were lower than in non-aerated tanks, while total phosphorus (TP) and dissolved phosphorus (DP) increased in spring and summer. In autumn, effects of aeration on the plants became more significant. TN, NH4(+)-N, TP and DP became higher in aerated tanks than in non-aerated tanks in autumn. This work provided evidences for regulating aeration techniques based on seasonal variations of the plant physiology in restoring polluted stagnant water.

  14. 不同流向对曝气生物滤池处理对对虾养殖污水效果的影响%Effect of different flows on wastewater treatment during Litopenaeus Vannamei culture by biological aerated filters

    Institute of Scientific and Technical Information of China (English)

    陈强; 黎中宝; 张艳艳; 王晨晨; 王超; 于凌宇

    2012-01-01

    In this experiment, the up-flow biological aerated filter ( UBAF) and down - flow biological aerated filter ( DBAF) were adopted to treat aquacultural wastewater of Litopenaeia vannamei. Trie water quality indexes such as chemical oxygen demand (COD), ammonia nitrogen ( NH3-N), nitrate nitrogen (N03 ~-N), nitrite nitrogen (NO2 -N), inorganic nitrogen (DIN) and soluble reactive phosphates (PO4-P) were measured and analysed during 30 days processing. The study was focused on the effect of the purification characteristics for aquacultural wastewater. Both the operating condition and the polluted condition of the wastewater treatment were also observed. The results showed that the removal rates and stability of UBAF was superior than that of DBAF. When the efluent concentrations of COD, NH3-N, NO," -N, N02--N, DINandPO1-Pwere7.62~8.20mg/L, 0.62 ~0.65 mg/L, 0.54-0. 59 mg/L, 0.23-0.27 mg/L, 1.40 -1.47 mg/L, 0.24 -0.29 mg/L, respectively, the removal rates of COD, NH,-N, N03~-N, NO2"-N, DIN and P04-P were 45.2% , 88.9% , 58.5% , 78.8% , 75.3% and 25. 1% , respectively at the temperature of 25 t - 30 *C by UBAF. The removal rates of NH3-N were the highest, fouowed by NO2" -N and DLN, COD and NO3" -N was lower, and PO4-P the lowest%采用上流式和下流式曝气生物滤池处理凡纳滨对虾(Litopenaeus vannamei)养殖污水,连续进行30 d,分析出水水质,并观察系统运行情况和装置污染状况.研究了养殖污水中化学需氧量、氨氮、硝酸盐氮、亚硝酸盐氮、无机氮及活性磷酸盐6项指标的去除效果.实验结果表明:从养殖污水主要污染物指标的去除效果和稳定性上看,上流式优于下流式曝气生物滤池.在系统进水化学需氧量质量浓度为7.62 ~8.20 mg/L、氨氮质量浓度为0.62~0.65 mg/L、硝酸盐氮质量浓度为0.54~0.59 mg/L、亚硝酸盐氮质量浓度为0.23 ~0.27 mg/L、无机氮质量浓度为1.40~1.47 mg/L、活性磷酸盐质量浓度为0.24 ~0.29 mg

  15. Gas-liquid mass transfer in a cross-flow hollow fiber module : Analytical model and experimental validation

    NARCIS (Netherlands)

    Dindore, V. Y.; Versteeg, G. F.

    2005-01-01

    The cross-flow operation of hollow fiber membrane contactors offers many advantages and is preferred over the parallel-flow contactors for gas-liquid mass transfer operations. However, the analysis of such a cross-flow membrane gas-liquid contactor is complicated due to the change in concentrations

  16. Methanogenesis acceleration of fresh landfilled waste by micro-aeration

    Institute of Scientific and Technical Information of China (English)

    SHAO Li-ming; HE Pin-jing; ZHANG Hua; YU Xiao-hua; LI Guo-jian

    2005-01-01

    When municipal solid waste(MSW) with high content of food waste is landfilled, the rapid hydrolysis of food waste results in the imbalance of anaerobic metabolism in the landfill layer, indicated by accumulation of volatile fatty acids(VFA) and decrease of pH value.This occurrence could lead to long lag time before the initiation of methanogenesis and to the production of strong leachate. Simulated landfill columns with forced aeration, with natural ventilation, and with no aeration, were monitored regarding their organics degradation rate with leachate recirculation. Hydrolysis reactions produced strong leachate in the column with no aeration. With forced aeration, the produced VFA could be effectively degraded, leading to the reduction in COD of the leachate effluent since the week 3. The CH4 in the frequency of twice/d, could amount to 40% (v/v) after only 20 weeks. This amount had increased up to 50% afterward even with no aeration. Most of COD in the recirculated leachate was removed. Using natural ventilation, CH4 could also be produced and the COD of the leachate effluent be reduced after 10 weeks of operation. However, the persistent existence of oxygen in the landfill layer yielded instability in methanogenesis process.

  17. Pure and aerated water entry of a flat plate

    Science.gov (United States)

    Ma, Z. H.; Causon, D. M.; Qian, L.; Mingham, C. G.; Mai, T.; Greaves, D.; Raby, A.

    2016-01-01

    This paper presents an experimental and numerical investigation of the entry of a rigid square flat plate into pure and aerated water. Attention is focused on the measurement and calculation of the slamming loads on the plate. The experimental study was carried out in the ocean basin at Plymouth University's COAST laboratory. The present numerical approach extends a two-dimensional hydro-code to compute three-dimensional hydrodynamic impact problems. The impact loads on the structure computed by the numerical model compare well with laboratory measurements. It is revealed that the impact loading consists of distinctive features including (1) shock loading with a high pressure peak, (2) fluid expansion loading associated with very low sub-atmospheric pressure close to the saturated vapour pressure, and (3) less severe secondary reloading with super-atmospheric pressure. It is also disclosed that aeration introduced into water can effectively reduce local pressures and total forces on the flat plate. The peak impact loading on the plate can be reduced by half or even more with 1.6% aeration in water. At the same time, the lifespan of shock loading is prolonged by aeration, and the variation of impulse is less sensitive to the change of aeration than the peak loading.

  18. Characterization of extracellular vesicles in whole blood: Influence of pre-analytical parameters and visualization of vesicle-cell interactions using imaging flow cytometry.

    Science.gov (United States)

    Fendl, Birgit; Weiss, René; Fischer, Michael B; Spittler, Andreas; Weber, Viktoria

    2016-09-09

    Extracellular vesicles are central players in intercellular communication and are released from the plasma membrane under tightly regulated conditions, depending on the physiological and pathophysiological state of the producing cell. Their heterogeneity requires a spectrum of methods for isolation and characterization, where pre-analytical parameters have profound impact on vesicle analysis, particularly in blood, since sampling, addition of anticoagulants, as well as post-sampling vesicle generation may influence the outcome. Here, we characterized microvesicles directly in whole blood using a combination of flow cytometry and imaging flow cytometry. We assessed the influence of sample agitation, anticoagulation, and temperature on post-sampling vesicle generation, and show that vesicle counts remained stable over time in samples stored without agitation. Storage with gentle rolling mimicking agitation, in contrast, resulted in strong release of platelet-derived vesicles in blood anticoagulated with citrate or heparin, whereas vesicle counts remained stable upon anticoagulation with EDTA. Using imaging flow cytometry, we could visualize microvesicles adhering to blood cells and revealed an anticoagulant-dependent increase in vesicle-cell aggregates over time. We demonstrate that vesicles adhere preferentially to monocytes and granulocytes in whole blood, while no microvesicles could be visualized on lymphocytes. Our data underscore the relevance of pre-analytical parameters in vesicle analysis and demonstrate that imaging flow cytometry is a suitable tool to study the interaction of extracellular vesicles with their target cells.

  19. A descaling treatment for aerated water, especially in cooling towers; Procede de traitement antitartre d`eau aeree, notamment dans les refrigerants atmospheriques

    Energy Technology Data Exchange (ETDEWEB)

    Delemont, F.; Mureau, P.

    1996-04-26

    Carbon dioxide is injected into the water aerating air, for example in the water flowing in a cooling tower; the dissolved carbon dioxide prevents scaling to take place on the heat exchange surfaces or leads to the dissolution of the deposited scale. This system has the advantage to avoid any acid use and thus polluting effluents. 2 refs.

  20. Exact Analytical Solution of the Magnetohydrodynamic Sink Flow%精确的磁流体动力学汇流解析解

    Institute of Scientific and Technical Information of China (English)

    章骥; 方铁钢; 钟永芳; 黄锋

    2011-01-01

    An exact analytical solution of the famous Falkner-Skan equation for magneto-hydro-dynamic (MHD) flow was obtained for a special case, namely the sink flow with a velocity power index of -1. The solution was given in a closed form. Multiple solution branches were observed. The effects of the magnetic parameter and the wall stretching parameter were analyzed. Interesting velocity profiles were observed with reversal flow regions even for a stationary wall. These solutions provide a rare case of the Falkner-Skan MHD flow with exact analytical closed form formula and greatly enrich the analytical solution to the celebrated Falkner-Skan equation and the understanding of this important and interesting equation.%就一个特殊的磁流体动力学(MHD)流动,即速度幂指数为-1时的汇流,得到著名的Falkner-Skan方程精确的解析解.解析解是封闭的,并有多重解分支.分析了磁场参数和壁面伸长参数的影响.发现了有趣的速度分布现象:即使壁面固定,回流区域依然出现.在一个罕见的FalknerSkan MHD流动中,得到了一组解,以精确封闭的解析公式表示,极大地丰富了著名的Falkner-Skan方程的解析解,也加深了对这重要又有趣方程的理解.

  1. The effects of lateral density gradients, slopes and buoyancy on channel flow: 1D analytical solutions and applications to the SE Canadian Cordillera

    Science.gov (United States)

    Gervais, Félix; Ranalli, Giorgio

    2017-08-01

    We present 1D analytical solutions for channel flow in orogens driven by various types of pressure gradients. Our calculations demonstrate that lateral density gradients in the upper crust, such as would occur across a suture zone separating arc rocks from pericratonic sediments provide a driving force for Poiseuille flow as large as topographic gradients observed in modern mountain belts. For cases for which the gradients are external (topographic and lateral density gradients) and internal (e.g. partial melting of channel material) to the channel, inclination decreases and increases the Poiseuille component of the average flow-velocity within the channel by the cosine and sine of the slope, respectively. The magnitude of the pressure gradient consequent upon the buoyancy generated by partial melting of metapelites in a channel with a 30° slope, such as would occur above an underthrusting basement ramp, is similar to that of topographic or lateral density gradients. Channel flow up a ramp could thus constitute an important exhumation mechanism in large hot orogens. Our calculations indicate that mid-crustal channel flow was a highly likely process in the Late Cretaceous-Paleocene setting of the southeastern Canadian Cordillera. The flow was first driven by the lateral density contrast between pericratonic sediments and the arc-related Intermontane terrane, then by combined effect of topographic gradient and melt-induced buoyancy of the Lower Selkirk Allochthon (part of the Shuswap Complex). Flow up the underthrusting basement ramp resulted in exhumation from mid- to upper-crustal levels. Channel flow then migrated downward to involve basement and overlying cover sequence rocks. Our results indicate that syn-convergent channel flow was a viable and very likely process in the southeastern Canadian Cordillera.

  2. Seasonal Variation of Nutrient Removal in a Full-Scale Artificial Aerated Hybrid Constructed Wetland

    Directory of Open Access Journals (Sweden)

    Jun Zhai

    2016-11-01

    Full Text Available To improve nutrient removal, a full-scale hybrid constructed wetland (CW consisting of pre-treatment units, vertical-baffled flow wetlands (VBFWs, and horizontal subsurface flow wetlands (HSFWs was installed in August 2014 to treat sewage wastewater. Artificial aeration (AA was applied continuously in the VBFW stage to improve the aerobic condition in the hybrid CW. Water samples were collected and analyzed twice a month between the period of August 2015 and July 2016. The results suggest that this new hybrid CW can achieve a satisfactory reduction of chemical oxygen demand (COD, ammonium nitrogen (NH4+-N, total nitrogen (TN, and total phosphorus (TP with average removal rates of 85% ± 10% (35% ± 19 g/m2 per day, 76% ± 18% (7% ± 2 g/m2 per day, 65% ± 13% (8% ± 2 g/m2 per day, and 65% ± 21% (1 g/m2 per day, respectively. AA significantly improved the aerobic condition throughout the experimental period, and the positive influence of AA on nitrogen removal was found to be higher during summer that during winter. A significant positive correlation between water temperature and nutrient removal (p < 0.01 was observed in the system. Overall, this study demonstrates the application of AA in a full-scale hybrid CW with satisfactory nutrient removal rates. The hybrid CW system with artificial aeration can serve as a reference for future applications areas where land availability is limited.

  3. Exact analytical solutions for moving boundary problems of one-dimensional flow in semi-infinite porous media with consideration of threshold pressure gradient

    Institute of Scientific and Technical Information of China (English)

    王晓冬; 朱光亚; 王磊

    2015-01-01

    By defining new dimensionless variables, nonlinear mathematical models for one-dimensional flow with unknown moving boundaries in semi-infinite porous media are modified to be solved analytically. The exact analytical solutions for both constant-rate and constant-pressure inner boundary constraint problems are obtained by applying the Green’s function. Two transcendental equations for moving boundary problems are obtained and solved using the Newton-Raphson iteration. The exact analytical solutions are then compared with the approximate solutions. The Pascal’s approximate formula in reference is fairly accurate for the moving boundary development under the constant-rate condition. But another Pascal’s approximate formula given in reference is not very robust for constant-pressure condition problems during the early production period, and could lead to false results at the maximum moving boundary distance. Our results also show that, in presence of larger TPG, more pressure drop is required to maintain a constant-rate production. Under the constant-pressure producing condition, the flow rate may decline dramatically due to a large TPG. What’s more, there exists a maximum distance for a given TPG, beyond which the porous media is not disturbed.

  4. Characteristics of integrated biological aerated filter in municipal wastewater treatment

    Institute of Scientific and Technical Information of China (English)

    HE Qiang; ZHANG Yu-ping; XU Jian-bin

    2005-01-01

    In this paper, the characteristics of integrated biological aerated filter (IBAF) applied to municipal wastewater treatment were studied in a pilot scale experiment. The experimental results showed that IBAF has high efficiencies in removing organic pollutants, such as CODCr and SS, in municipal wastewater. The removal rates of CODCr and SS can reach over 90% and 80%, respectively, when COD and SS in the influent are 234 mg L-1 and 112 mg L-1, hydraulic retention time (HRT) is 8 h, and the aerated intensity is in the range of (0.5 to 0.6) L m-2 s-1.

  5. A nonlinear analytical model for the squeeze-film dynamics of parallel plates subjected to axial flow

    Energy Technology Data Exchange (ETDEWEB)

    Piteau, Ph. [CEA Saclay, DEN, DM2S, SEMT, DYN, CEA, Lab Etud Dynam, F-91191 Gif Sur Yvette (France); Antunes, J. [ITN, ADL, P-2686 Sacavem Codex (Portugal)

    2010-07-01

    In this paper, we develop a theoretical model to predict the nonlinear fluid-structure interaction forces and the dynamics of parallel vibrating plates subjected to an axial gap flow. The gap is assumed small, when compared to the plate dimensions, the plate width being much larger than the length, so that the simplifying assumptions of 1D bulk-flow models are adequate. We thus develop a simplified theoretical squeeze-film formulation, which includes both the distributed and singular dissipative flow terms. This model is suitable for performing effective time-domain numerical simulations of vibrating systems which are coupled by the nonlinear unsteady flow forces, for instance the vibro-impact dynamics of plates with fluid gap interfaces. A linearized version of the flow model is also presented and discussed, which is appropriate for studying the complex modes and linear stability of flow/structure coupled systems as a function of the average axial gap velocity. Two applications of our formulation are presented: (1) first we study how an axial flow modifies the rigid-body motion of immersed plates falling under gravity; (2) then we compute the dynamical behavior of an immersed oscillating plate as a function of the axial gap flow velocity. Linear stability plots of oscillating plates are shown, as a function of the average fluid gap and of the axial flow velocity, for various scenarios of the loss terms. These results highlight the conditions leading to either the divergence or flutter instabilities. Numerical simulations of the nonlinear flow/structure dynamical responses are also presented, for both stable and unstable regimes. This work is of interest to a large body of real-life problems, for instance the dynamics of nuclear spent fuel racks immersed in a pool when subjected to seismic excitations, or the self-excited vibro-impact motions of valve-like components under axial flows. (authors)

  6. Optimization of submerged depth of surface aerators for a carrousel oxidation ditch based on large eddy simulation with Smagorinsky model.

    Science.gov (United States)

    Wei, Wenli; Bai, Yu; Liu, Yuling

    2016-01-01

    This paper is concerned with the simulation and experimental study of hydraulic characteristics in a pilot Carrousel oxidation ditch for the optimization of submerged depth ratio of surface aerators. The simulation was based on the large eddy simulation with the Smagorinsky model, and the velocity was monitored in the ditches with an acoustic Doppler velocimeter method. Comparisons of the simulated velocities and experimental ones show a good agreement, which validates that the accuracy of this simulation is good. The best submerged depth ratio of 2/3 for surface aerators was obtained according to the analysis of the flow field structure, the ratio of gas and liquid in the bottom layer of a ditch, the average velocity of mixture and the flow region with a velocity easily causing sludge deposition under the four operation conditions with submerged depth ratios of 1/3, 1/2, 2/3 and 3/4 for surface aerators. The research result can provide a reference for the design of Carrousel oxidation ditches.

  7. Strategy for solving semi-analytically three-dimensional transient flow in a coupled N-layer aquifer system

    NARCIS (Netherlands)

    Veling, E.J.M.; Maas, C.

    2008-01-01

    Efficient strategies for solving semi-analytically the transient groundwater head in a coupled N-layer aquifer system phi(i)(r, z, t), i = 1, ..., N, with radial symmetry, with full z-dependency, and partially penetrating wells are presented. Aquitards are treated as aquifers with their own horizont

  8. Analytic representations of high-altitude auroral H^+ and O^+ densities, flow velocities and temperatures in terms of drivers for incorporation into global magnetospheric models

    Science.gov (United States)

    Horwitz, James; Zeng, Wen

    2008-10-01

    As new methods of describing multiple fluid species and other advances enhance the capability of global magnetospheric models to simulate the dynamics of multiple ion species, they also allow more accurate incorporation of ionospheric plasma outflows as source populations into these large scale models. Here, we shall describe the distilled results of numerous physics-based simulations of ionospheric plasma outflows influenced by auroral driving agents in terms of compact analytic expressions in terms of precipitation electron energy flux levels, characteristic energy levels of the precipitating electrons, the peak spectral wave densities for low-frequency electrostatic waves which transversely heat ionospheric ions, and solar zenith angle. The simulations are conducted with the UT Arlington Dynamic Fluid Kinetic (DyFK) ionospheric plasma transport code. We present these analytic expressions for ionospheric origin O^+ and H^+ densities, temperatures and field-aligned flow velocities at the 3 RE altitude inner boundaries of typical magnetospheric models.

  9. Comparison Study on Empirical Correlation for Mass Transfer Coefficient with Gas Hold-up and Input Power of Aeration Process

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sang Kyoo; Yang, Hei Cheon [Chonnam Nat’l Univ., Gwangju (Korea, Republic of)

    2017-06-15

    As stricter environmental regulation have led to an increase in the water treatment cost, it is necessary to quantitatively study the input power of the aeration process to improve the energy efficiency of the water treatment processes. The objective of this study is to propose the empirical correlations for the mass transfer coefficient with the gas hold-up and input power in order to investigate the mass transfer characteristics of the aeration process. It was found that as the input power increases, the mass transfer coefficient increases because of the decrease of gas hold-up and increase of Reynolds number, the penetration length, and dispersion of mixed flow. The correlations for the volumetric mass transfer coefficients with gas hold-up and input power were consistent with the experimental data, with the maximum deviation less than approximately ±10.0%.

  10. Anammox brings WWTP closer to energy autarky due to increased biogas production and reduced aeration energy for N-removal.

    Science.gov (United States)

    Siegrist, H; Salzgeber, D; Eugster, J; Joss, A

    2008-01-01

    Fifty years ago when only BOD was removed at municipal WWTPs primary clarifiers were designed with 2-3 hours hydraulic retention time (HRT). This changed with the introduction of nitrogen removal in activated sludge treatment that needed more BOD for denitrification. The HRT of primary clarification was reduced to less than one hour for dry weather flow with the consequence that secondary sludge had to be separately thickened and biogas production was reduced. Only recently the ammonia rich digester liquid (15-20% of the inlet ammonia load) could be treated with the very economic autotrophic nitritation/anammox process requiring half of the aeration energy and no organic carbon source compared to nitrification and heterotrophic denitrification. With the introduction of this new innovative digester liquid treatment the situation reverts, allowing us to increase HRT of the primary clarifier to improve biogas production and reduce aeration energy for BOD removal and nitrification at similar overall N-removal.

  11. Comparison between lab- and full-scale applications of in situ aeration of an old landfill and assessment of long-term emission development after completion.

    Science.gov (United States)

    Hrad, Marlies; Gamperling, Oliver; Huber-Humer, Marion

    2013-10-01

    Sustainable landfilling has become a fundamental objective in many modern waste management concepts. In this context, the in situ aeration of landfills has been recognised for its potential to convert conventional anaerobic landfills into biological stabilised state, whereby both current and potential (long-term) emissions of the landfilled waste are mitigated. In recent years, different in situ aeration concepts have been successfully applied in Europe, North America and Asia, all pursuing different objectives and strategies. In Austria, the first full-scale application of in situ landfill aeration by means of low pressure air injection and simultaneous off-gas collection and treatment was implemented on an old, small municipal solid waste (MSW) landfill (2.6ha) in autumn 2007. Complementary laboratory investigations were conducted with waste samples taken from the landfill site in order to provide more information on the transferability of the results from lab- to full-scale aeration measures. In addition, long-term emission development of the stabilised waste after aeration completion was assessed in an ongoing laboratory experiment. Although the initial waste material was described as mostly stable in terms of the biological parameters gas generation potential over 21days (GP21) and respiration activity over 4days (RA4), the lab-scale experiments indicated that aeration, which led to a significant improvement of leachate quality, was accompanied by further measurable changes in the solid waste material under optimised conditions. Even 75weeks after aeration completion the leachate, as well as gaseous emissions from the stabilised waste material, remained low and stayed below the authorised Austrian discharge limits. However, the application of in situ aeration at the investigated landfill is a factor 10 behind the lab-based predictions after 3years of operation, mainly due to technical limitations in the full-scale operation (e.g. high air flow resistivity due

  12. 一种新型掺气设施的试验研究%An experimental study on hydraulic characteristics of a novel aerator

    Institute of Scientific and Technical Information of China (English)

    牛争鸣; 南军虎; 洪镝

    2013-01-01

    The use of an annularaerator placing in the vertical shaft of flood discharge tunnel is a new engineering idea,and is different from the traditional ones.In order to better understand this new type of technology,the ventilation and aeration characteristics of the annular aerator are studied based on the prototype and modeling experiments carried out in the gyrating discharge tunnel of the Gongboxia Hydropower Project.The results show that the ventilation is caused by the pressure difference of air vents.The relationship between the ventilation and relative cavity length follows the linear distribution.The aeration effect on the annular aerator is obvious.The jet is striking water in the shaft,and then a large-scale aerated vortex is generated with bubbles thereby contributing to the aeration forming.The aeration concentration presents a power distribution in the vertical shaft.The ventilation and aeration scale effects of models are both obvious.Therefore,the use of an annular aerator is necessary to set in the vertical shaft of gyrating discharge tunnel while satisfying the structural designs demands,which can improve the flow pattern and increase the energy dissipation significantly.%设置在泄洪洞竖井内的环形掺气设施是不同于传统掺气技术的新创意.为了更好地认识这种新型的掺气技术,基于公伯峡水平旋流泄洪洞原型和模型试验,对环形掺气坎的通风和掺气特性进行了研究.结果表明环形通气孔的通风是由通气孔进出口的压差引起的,通风量与相对空腔长度的关系服从线性分布;环形掺气坎掺气减蚀的作用明显,其掺气是由于射流冲击竖井水体形成大尺度旋涡并挟带气泡所致,且掺气浓度沿高程呈乘幂分布;模型通风和掺气特性的缩尺效应明显.在结构设计满足要求的前提下,有必要在旋流泄洪洞的竖井段设置掺气设施,可改善水流流态,并增加消能效果.

  13. Colloid formation in groundwater by subsurface aeration: characterisation of the geo-colloids and their counterparts

    NARCIS (Netherlands)

    Wolthoorn, A.; Temminghoff, E.J.M.; Riemsdijk, van W.H.

    2004-01-01

    Subsurface aeration is used to oxidise Fe in situ in groundwater to make the water potable. In a groundwater system with pH > 7, subsurface aeration results in a non-mobile Fe precipitate and mobile Fe colloids. Since originally the goal of subsurface aeration is to remove Fe in situ, the

  14. 7 CFR 201.55a - Moisture and aeration of substratum.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Moisture and aeration of substratum. 201.55a Section... and aeration of substratum. (a) The substratum must be moist enough to supply the needed moisture to the seeds at all times. Excessive moisture which will restrict aeration of the seeds should be...

  15. Effect of cyclic aeration on fouling in submerged membrane bioreactor for wastewater treatment.

    Science.gov (United States)

    Wu, Jun; He, Chengda

    2012-07-01

    Due to the inefficiency of aeration measures in preventing fouling by soluble and colloidal particles. The effect of alternating high/low cyclic aeration mode on the membrane fouling in the submerged membrane bioreactor was studied by comparing to fouling in a constant aeration mode. Results indicated a higher overall fouling rate in the cyclic aeration mode than in the constant aeration. However, a higher percentage of reversible fouling was observed for the cyclic aeration mode. The membrane permeability can be more easily recovered from physical cleaning such as backwashing in the cyclic aeration mode. The activated sludge floc size distribution analysis revealed a floc destruction and re-flocculation processes caused by the alternating high/low aeration. The short high aeration period could prevent the destruction of strong strength bonds within activated sludge flocs. Therefore, less soluble and colloidal material was observed in the supernatant due to the preservation of the strong strength bonds. The weak strength bonds damaged in the high aeration period could be recovered in the re-flocculation process in the low aeration period. The floc destruction and re-flocculation processes were suggested to be the main reason for the low irreversible fouling in the cyclic aeration mode.

  16. Temperature stratification and insect pest populations in stored wheat with suction versus pressure aeration

    Science.gov (United States)

    A three-year study was conducted to compare temperature profiles in the headspace and in the bulk mass of wheat aerated through pressure aeration and suction aeration. Insect pitfall traps were used to measure naturally-occurring populations of stored product insects. Results show uniform distributi...

  17. Heavy metal adsorptivity of calcium-alginate-modified diethylenetriamine-silica gel and its application to a flow analytical system using flame atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Mori, Masanobu, E-mail: mori@gunma-u.ac.jp [Graduate School of Science and Technology, Gunma University, 1-5-1, Tenjin-cho, Kiryu 376-8515, Japan, (Japan); Suzuki, Toshinobu; Sugita, Tsuyoshi; Nagai, Daisuke [Graduate School of Science and Technology, Gunma University, 1-5-1, Tenjin-cho, Kiryu 376-8515, Japan, (Japan); Hirayama, Kazuo [College of Engineering, Nihon University, 1 Nakagawara, Tokusada, Tamuramachi, Koriyama, Fukushima 963-8642 (Japan); Onozato, Makoto; Itabashi, Hideyuki [Graduate School of Science and Technology, Gunma University, 1-5-1, Tenjin-cho, Kiryu 376-8515, Japan, (Japan)

    2014-08-20

    Highlights: • Calcium-alginate-modified dien-silica gel adsorbed multivalent metal ions. • Metal ions adsorbed on CaAD were eluted using low acidic concentrations. • Flow system with CaAD-packed column enriched metal concentrations up to 50-fold. - Abstract: This study aimed to evaluate the heavy metal adsorptivity of calcium-alginate-modified diethylenetriamine-silica gel (CaAD) and incorporate this biosorbent into a flow analytical system for heavy metal ions using flame atomic absorption spectrometry (FAAS). The biosorbent was synthesized by electrostatically coating calcium alginate onto diethylenetriamine (dien)-silica gel. Copper ion adsorption tests by a batch method showed that CaAD exhibited a higher adsorption rate compared with other biosorbents despite its low maximum adsorption capacity. Next, CaAD was packed into a 1 mL microcolumn, which was connected to a flow analytical system equipped with an FAAS instrument. The flow system quantitatively adsorbed heavy metals and enriched their concentrations. This quantitative adsorption was achieved for pH 3–4 solutions containing 1.0 × 10{sup −6} M of heavy metal ions at a flow rate of 5.0 mL min{sup −1}. Furthermore, the metal ions were successfully desorbed from CaAD at low nitric acid concentrations (0.05–0.15 M) than from the polyaminecarboxylic acid chelating resin (Chelex 100). Therefore, CaAD may be considered as a biosorbent that quickly adsorbs and easily desorbs analyte metal ions. In addition, the flow system enhanced the concentrations of heavy metals such as Cu{sup 2+}, Zn{sup 2+}, and Pb{sup 2+} by 50-fold. This new enrichment system successfully performed the separation and determination of Cu{sup 2+} (5.0 × 10{sup −8} M) and Zn{sup 2+} (5.7 × 10{sup −8} M) in a river water sample and Pb{sup 2+} (3.8 × 10{sup −9} M) in a ground water sample.

  18. Two-Phase Air/Oil Flow in Aero-Engine Bearing Chambers – Assessment of an Analytical Prediction Method for the Internal Wall Heat Transfer

    Directory of Open Access Journals (Sweden)

    A. Glahn

    1999-01-01

    Full Text Available The present paper gives a theoretical outline on liquid film flows driven by superimposed effects of interfacial shear and gravity forces and discusses related heat transfer processes which are relevant for lubrication oil systems of aero engines. It is shown that a simple analytical approach is able to predict measured heat transfer data fairly well. Therefore, it offers scope for improvements within the analysis of bearing chamber heat transfer characteristics as well as for appropriate studies with respect to other components of the lubrication oil system such as vent pipeline elements.

  19. Effect of media heights on the performance of biological aerated filter

    Institute of Scientific and Technical Information of China (English)

    HU Yong-you; WANG Li-li

    2005-01-01

    The optimum media height of carbon oxidation and nitrification in a down-flow biological aerated filter was determined, and the distribution of the heterotrophic and nitrifying populations through studying the changes of organic carbon contents and ammonia concentration at different media height was got. The results showed that as a down flow BAF with granular media, the active layer of nitrifiers was deeper than heterotrophs in BAF. And the optimum media height for the removal of SS, CODCr and NH4+ -N was 40 cm,60 cm and 80 cm respectively. The removal efficiency of SS, CODCr and NH4+-N was 79.1%, 63.9% and 96.4% respectively under the influent CODCr and NH4+ -N of 122.1 mgCODCr/L and 14.84 mgNH4+ -N/L, the influent flux of 15.8 L/h, air to liquid ratio of 3: 1.

  20. Studies of the analyte-carrier interface in flow injection analysis. Final report, June 1, 1987--January 31, 1992

    Energy Technology Data Exchange (ETDEWEB)

    Brown, S.D.

    1992-12-31

    Chemical analysis in flowing solution is popular for automation of classical methods. However, most of the classical methods are not specific enough for direct multicomponent analysis of simple mixtures. This research project has the goals of study of rapid multicomponent analysis of transient species in flowing media, and investigations of chemical reactions at interfaces and of effects of competition on distribution of products from interfacial reaction. This report summarizes work done over the past 4.5 years; support has been terminated.

  1. Aeration of bread dough influenced by different way processing

    NARCIS (Netherlands)

    Peighambardoust, S.H.; Fallah, E.; Hamer, R.J.; Goot, van der A.J.

    2010-01-01

    The effect of steady shearing versus z-blade mixing on mechanical aeration and gas retaining ability of the dough during processing and subsequent proofing and bread baking stages was investigated. Reduction in moisture content led to reduction in both static and dynamic densities of z-blade mixed

  2. Nutrients removal using moving beds with aeration cycles

    Energy Technology Data Exchange (ETDEWEB)

    Martin Martin, A.; Foresti, E.; Garcia-Encina, P. A.

    2009-07-01

    Moving Bed Biofilm Reactors (MBBR) are based on the biomass growth over a media that moves into the reactor due to aeration, mechanical agitation or recirculation. These reactors have been gaining popularity and they are employed in hundreds of plants everywhere with different treatment purposes (organic matter removal, nitrification/denitrification), both for urban and industrial wastewater. (Author)

  3. Landfill aeration for emission control before and during landfill mining.

    Science.gov (United States)

    Raga, Roberto; Cossu, Raffaello; Heerenklage, Joern; Pivato, Alberto; Ritzkowski, Marco

    2015-12-01

    The landfill of Modena, in northern Italy, is now crossed by the new high velocity railway line connecting Milan and Bologna. Waste was completely removed from a part of the landfill and a trench for the train line was built. With the aim of facilitating excavation and further disposal of the material extracted, suitable measures were defined. In order to prevent undesired emissions into the excavation area, the aerobic in situ stabilisation by means of the Airflow technology took place before and during the Landfill Mining. Specific project features involved the pneumatic leachate extraction from the aeration wells (to keep the leachate table low inside the landfill and increase the volume of waste available for air migration) and the controlled moisture addition into a limited zone, for a preliminary evaluation of the effects on process enhancement. Waste and leachate were periodically sampled in the landfill during the aeration before the excavation, for quality assessment over time; the evolution of biogas composition in the landfill body and in the extraction system for different plant set-ups during the project was monitored, with specific focus on uncontrolled migration into the excavation area. Waste biological stability significantly increased during the aeration (waste respiration index dropped to 33% of the initial value after six months). Leachate head decreased from 4 to 1.5m; leachate recirculation tests proved the beneficial effects of moisture addition on temperature control, without hampering waste aerobization. Proper management of the aeration plant enabled the minimization of uncontrolled biogas emissions into the excavation area.

  4. Internal aeration development and the zonation of plants in wetlands

    DEFF Research Database (Denmark)

    Sorrell, Brian Keith

    support many species which have root aeration adaptations but are otherwise unspecialised for aquatic life. Permanent standing water is a much greater challenge for plants, and survival here is restricted to species with special adaptations to their oxygen transport physiology such as the development...

  5. Biological Nutrient Removal in an Intermittently Aerated Bioreactor

    Directory of Open Access Journals (Sweden)

    J. Derco

    2017-07-01

    Full Text Available The extension of biological processes from carbonaceous impurities removal to nitrogen and phosphorus removal had an impact on the biological system configuration. The system must be well designed, optimized, and operated at its optimum in order to meet the ever more stringent effluent standards. An intermittently aerated completely mixed lab-scale activated sludge bioreactor (IACMB has been used for modelling biological processes of nutrients removal. Concerning the nitrogen removal, the operating cycles 15–30 (15 minutes of aeration, 30 minutes of only mixing without aeration and 30–30 were tested. For the experiments with luxury uptake processes, the operating cycles 15–45, 15–90, 30–60 and 15–75 were used. The cycle 15–75 was the most satisfactory with convenient lengths of aerobic, anoxic, and anaerobic period, high efficiency of the nitrification and denitrification processes, and significant decrease in phosphorus concentration. The results have shown that the intermittently aerated bioreactors are suitable for nitrogen removal as well as luxury uptake of phosphorus. The main advantage is high flexibility in maintenance and control of biochemical environments in the bioreactor.

  6. PROJECT OF COAGULANT DISPENSER IN PULVERIZATION AERATOR WITH WIND DRIVE

    Directory of Open Access Journals (Sweden)

    Ewa Osuch

    2017-09-01

    Full Text Available Lakes are one of most important freshwater ecosystems, playing significant role in functioning of nature and human economy. Swarzędzkie Lake is good example of ecosystem, which in last half-century was exposed to the influence of strong anthropopressure. Direct inflow of sewage with large number of biogens coming to the lake with water of inflows caused distinct disturbance of its functioning. In autumn 2011 restoration begined on Swarzędzkie Lake for reduction of lake trophy and improvement of water quality. For achieving better and quicker effect, simultaneously combination of some methods was applied, among others method of oxygenation of over-bottom water with help of pulverization aerator and method of precise inactivation of phosphorus in water depths. Characterization and analysis of improved coagulant dispenser applying active substance only during work of pulverization aerator is the aim of this thesis. Principle of dispenser work, its structure and location in pulverization aerator were explained. It was stated, that introduction to water a factor initiating process of phosphorus inactivation causes significant reduction of mineral phosphorus in water and size of coagulant dose correlates with intensity of work of pulverization aerator with wind drive.

  7. Aeration of bread dough influenced by different way processing

    NARCIS (Netherlands)

    Peighambardoust, S.H.; Fallah, E.; Hamer, R.J.; Goot, van der A.J.

    2010-01-01

    The effect of steady shearing versus z-blade mixing on mechanical aeration and gas retaining ability of the dough during processing and subsequent proofing and bread baking stages was investigated. Reduction in moisture content led to reduction in both static and dynamic densities of z-blade mixed d

  8. Methane biofiltration using Autoclaved Aerated Concrete as the carrier material

    NARCIS (Netherlands)

    Ganendra, Giovanni; Mercado-Garcia, Daniel; Hernandez-Sanabria, Emma; Boeckx, P.; Ho, Adrian; Boon, N.

    2015-01-01

    The methane removal capacity of mixed methane-oxidizing bacteria (MOB) culture in a biofilter setup using autoclaved aerated concrete (AAC) as a highly porous carrier material was tested. Batch experiment was performed to optimize MOB immobilization on AAC specimens where optimum methane removal was

  9. HYDRAULIC CHARACTERISTICS OF CHUTE AERATORS FOR RELEASE WORKS

    Institute of Scientific and Technical Information of China (English)

    RUAN Shi-ping

    2008-01-01

    On the basis of model tests and theoretical analysis, hydraulic characteristics, air demand, air concentration distribution and their relationships between prototype and model of an aerator were studied. Some computational examples show that the present methods have higher accuracy, and can meet the need of engineering design.

  10. Analytic Back Calculation of Debris Flow Damage Incurred to a Masonry Building: The Case of Scaletta Zanclea 2009 Event

    Directory of Open Access Journals (Sweden)

    Soleimankhani Hossein

    2016-01-01

    Full Text Available In an attempt to do a back analysis of the damages caused to a nineteenth century masonry structure due to the October 2009 flash flood/debris flow event in Scaletta Zanclea, the flood discharge hydrograph is reconstructed in the ungauged conditions. The hydrograph for the solid discharge is then estimated by scaling up the liquid volume to the estimated debris volume. The debris flow diffusion is simulated by solving the differential equations for a single-phase 2D flow employing triangular mesh elements, taking into account also the channelling of the flow through the buildings. The damage to the building is modelled, based on the maximum hydraulic actions caused by the debris flow, using 2D finite shell elements to model the building, boundary conditions provided by the openings, floor slab, orthogonal wall panels, and the foundation. The reconstruction of the event and the damages to the case-study building confirms the location of the damages induced by the event.

  11. Treatment of Alkaline Stripped Effluent in Aerated Constructed Wetlands: Feasibility Evaluation and Performance Enhancement

    Directory of Open Access Journals (Sweden)

    Keli He

    2016-09-01

    Full Text Available Ammonium stripping has gained increasing interest for nitrogen recovery in anaerobically digested effluents. However, the stripped effluents often still do not meet discharge standards, having high pH and residual pollutants. Constructed wetlands (CWs are an easy to operate ecosystem and have a long history of application in treatment of wastewaters with extreme pH, such as acid mine drainage. However, knowledge of the mechanistic details involved in the use of CWs to treat high alkaline drainage, such as stripped effluent, is insufficient. This study explored the feasibility and effectiveness of using three sub-surface horizontal flow CWs to treat high alkaline stripped effluent (pH > 10. Two intensification strategies—intermittent aeration and effluent recirculation—were evaluated to enhance nitrogen depuration performance. The results show that the treatment of alkaline stripped effluent is feasible due to the high buffering capacity of the wetlands. Effluent recirculation combined with intermittent artificial aeration improves nitrogen removal, with 71% total nitrogen (TN removal. Ammonia volatilization from the surface of the wetlands in high alkaline conditions only contributed to 3% of the total removed ammonium. The microbial abundance and activity had significant diversity for the various enhancement strategies used in the constructed wetland systems. Anammox is an important process for nitrogen removal in CWs treating alkaline stripped effluent, and possible enhancements of this process should be investigated further.

  12. Oxygen air enrichment through composite membrane: application to an aerated biofilm reactor

    Directory of Open Access Journals (Sweden)

    A. C. Cerqueira

    2013-12-01

    Full Text Available A highly permeable composite hollow-fibre membrane developed for air separation was used in a membrane aerated biofilm reactor (MABR. The composite membrane consisted of a porous support layer covered with a thin dense film, which was responsible for oxygen enrichment of the permeate stream. Besides oxygen enrichment capability, dense membranes overcome major operational problems that occur when using porous membranes for oxygen transfer to biofilms. Air flow rate and oxygen partial pressure inside the fibres were the variables used to adjust the oxygen transfer rate. The membrane aerated biofilm reactor was operated with hydraulic retention times (HRT ranging from 1 to 4 hours. High organic load removal rates, like 6.5 kg.m-3.d-1, were achieved due to oxygen transfer rates as high as 107 kg.m-3.d-1. High COD removals, with improved oxygen transfer efficiency, indicate that a MABR is a compact alternative to the conventional activated sludge process and that the selected membrane is suitable for further applications.

  13. Sequential Aeration of Membrane-Aerated Biofilm Reactors for High-Rate Autotrophic Nitrogen Removal: Experimental Demonstration

    DEFF Research Database (Denmark)

    Pellicer i Nàcher, Carles; Sun, Sheng-Peng; Lackner, Susanne;

    2010-01-01

    One-stage autotrophic nitrogen (N) removal, requiring the simultaneous activity of aerobic and anaerobic ammonium oxidizing bacteria (AOB and AnAOB), can be obtained in spatially redox-stratified biofilms. However, previous experience with Membrane-Aerated Biofilm Reactors (MABRs) has revealed...

  14. Intermittent Aeration Suppresses Nitrite-Oxidizing Bacteria in Membrane-Aerated Biofilms: A Model-Based Explanation

    DEFF Research Database (Denmark)

    Ma, Yunjie; Domingo Felez, Carlos; Plósz, Benedek G.

    2017-01-01

    Autotrophic ammonium oxidation in membrane-aerated biofilm reactors (MABRs) can make treatment of ammonium-rich wastewaters more energy-efficient, especially within the context of short-cut ammonium removal. The challenge is to exclusively enrich ammonium-oxidizing bacteria (AOB). To achieve...

  15. Analytical Modelling of Three-Dimensional Squeezing Nanofluid Flow in a Rotating Channel on a Lower Stretching Porous Wall

    Directory of Open Access Journals (Sweden)

    Navid Freidoonimehr

    2014-01-01

    Full Text Available A coupled system of nonlinear ordinary differential equations that models the three-dimensional flow of a nanofluid in a rotating channel on a lower permeable stretching porous wall is derived. The mathematical equations are derived from the Navier-Stokes equations where the governing equations are normalized by suitable similarity transformations. The fluid in the rotating channel is water that contains different nanoparticles: silver, copper, copper oxide, titanium oxide, and aluminum oxide. The differential transform method (DTM is employed to solve the coupled system of nonlinear ordinary differential equations. The effects of the following physical parameters on the flow are investigated: characteristic parameter of the flow, rotation parameter, the magnetic parameter, nanoparticle volume fraction, the suction parameter, and different types of nanoparticles. Results are illustrated graphically and discussed in detail.

  16. 浅论掺气设施的消能作用%Study on the Energy Dissipation of Aerator

    Institute of Scientific and Technical Information of China (English)

    栗帅; 张建民; 陈剑刚; 胡小禹

    2011-01-01

    掺气减蚀设施不仅能有效地减缓空蚀和磨蚀的发生,而且具有一定的消能作用.结合某水电站溢洪道的模型试验研究,分析了溢洪道掺气减蚀工程措施的消能效果,并首次定量地计算了消能率.试验和计算结果表明,在高水头、大单宽流量溢洪道中每道掺气挑坎的消能水头为2~5 m,随着级数的增加消能水头逐渐增加.试验还表明,在满足掺气要求和水流流态平稳的条件下,尽可能多设置掺气设施不仅不会增加工程量,还可以降低泄槽因高速水流冲刷破坏的风险,而且有利于下游消能防冲设计的优化.%Air entrainment facilities can not only effectively reduce the occurrence of cavitation and abrasion, but also has a certain role on energy dissipation. Combining with the experimental research of a spillway model, the energy dissipation of the aerator in the spillway is analyzed and the energy dissipation rate is firstly quantified. The results show that the head will decrease about 2-5 m after flowing through an aerator in a spillway with high water head and large unit discharge, and the head decrease will be increased with the increase of the number of aerators. The experimental study also shows that, under the conditions of meeting the requirements of aeration and keeping flow stable, setting the aerators as much as possible will not increase the construction quantity, but it can reduce the risk of chute damage due to high-speed flow and is beneficial to the optimization of downstream energy dissipation and erosion control designs.

  17. Redox potential driven aeration during very-high-gravity ethanol fermentation by using flocculating yeast.

    Science.gov (United States)

    Liu, Chen-Guang; Hao, Xue-Mi; Lin, Yen-Han; Bai, Feng-Wu

    2016-05-10

    Ethanol fermentation requires oxygen to maintain high biomass and cell viability, especially under very-high-gravity (VHG) condition. In this work, fermentation redox potential (ORP) was applied to drive the aeration process at low dissolved oxygen (DO) levels, which is infeasible to be regulated by a DO sensor. The performance and characteristics of flocculating yeast grown under 300 and 260 g glucose/L conditions were subjected to various aeration strategies including: no aeration; controlled aeration at -150, -100 and -50 mV levels; and constant aeration at 0.05 and 0.2 vvm. The results showed that anaerobic fermentation produced the least ethanol and had the highest residual glucose after 72 h of fermentation. Controlled aerations, depending on the real-time oxygen demand, led to higher cell viability than the no-aeration counterpart. Constant aeration triggered a quick biomass formation, and fast glucose utilization. However, over aeration at 0.2 vvm caused a reduction of final ethanol concentration. The controlled aeration driven by ORP under VHG conditions resulted in the best fermentation performance. Moreover, the controlled aeration could enhance yeast flocculating activity, promote an increase of flocs size, and accelerate yeast separation near the end of fermentation.

  18. Performance of completely autotrophic nitrogen removal over nitrite process under different aeration modes and dissolved oxygen

    Institute of Scientific and Technical Information of China (English)

    Jinsong GUO; Guohong YANG; Fang FANG; Yu QIN

    2008-01-01

    In this study, three sequential batch biofilm reactors (SBBRs) were operated for 155 days to evaluate the performance of completely autotrophic nitrogen removal over nitrite (CANON) process under different aeration modes and dissolved oxygen (DO). Synthetic wastewater with 160-mg NH4+-N/L was fed into the reac-tors. In the continuously-aerated reactor, the efficiency of the ammonium nitrogen conversion and total nitrogen (TN) removal reached 80% and 70%, respectively, with DO between 0.8-1.0 mg/L. Whereas in the intermit-tently-aerated reactor, at the aeration/non-aeration ratio of 1.0, ammonium was always under the detection limit and 86% of TN was removed with DO between 2.0 2.5 mg/L during the aeration time. Results show that CANON could be achieved in both continuous and inter-mittent aeration pattern. However, to achieve the same nitrogen removal efficiency, the DO needed in the inter-mittently-aerated sequential batch biofilm reactor (SBBR) during the aeration period was higher than that in the continuously-aerated SBBR. In addition, the DO in the CANON system should be adjusted to the aeration mode, and low DO was not a prerequisite to CANON process.

  19. Analytical studies on an extended car following model for mixed traffic flow with slow and fast vehicles

    Science.gov (United States)

    Li, Zhipeng; Xu, Xun; Xu, Shangzhi; Qian, Yeqing; Xu, Juan

    2016-07-01

    The car-following model is extended to take into account the characteristics of mixed traffic flow containing fast and slow vehicles. We conduct the linear stability analysis to the extended model with finding that the traffic flow can be stabilized with the increase of the percentage of the slow vehicle. It also can be concluded that the stabilization of the traffic flow closely depends on not only the average value of two maximum velocities characterizing two vehicle types, but also the standard deviation of the maximum velocities among all vehicles, when the percentage of the slow vehicles is the same as that of the fast ones. With increase of the average maximum velocity, the traffic flow becomes more and more unstable, while the increase of the standard deviation takes negative effect in stabilizing the traffic system. The direct numerical results are in good agreement with those of theoretical analysis. Moreover, the relation between the flux and the traffic density is investigated to simulate the effects of the percentage of slow vehicles on traffic flux in the whole density regions.

  20. Effects of the rate of releases from Sam Rayburn Reservoir on the Aeration Capacity of the Angelina River, eastern Texas

    Science.gov (United States)

    Rawson, Jack; Goss, Richard L.; Rathbun, Ira G.

    1980-01-01

    A three-phase study was conducted during July and August 1979 to determine the effects of varying release rates through the power-outlet works at Sam Rayburn Reservoir, eastern Texas, on aeration capacity of a 14-mile reach of the Angelina River below Sam Rayburn Dam. The dominant factors that affected the aeration capacity during the study time were time of travel and the dissolved-oxygen deficit of the releases. Aeration was low throughout the study but increased in response to increases in the dissolved-oxygen deficit and the duration of time that the releases were exposed to the atmosphere (time of travel). The average concentration of dissolved oxygen sustained by release of 8,800 cubic feet per second decreased from 5.0 milligrams per liter at a site near the power outlet to 4.8 milligrams per liter at a site about 14 miles downstream; the time of travel averaged about 8 hours. The average concentration of dissolved oxygen in flow sustained by releases of 2,200 cubic feet per second increased from 5.2 to 5.5 milligrams per liter; the time of travel averaged about 20 hours. (USGS)

  1. ENERGY COMPONENTS OF GAS-LIQUID FLOW IN AEROTANK

    Directory of Open Access Journals (Sweden)

    Frolova Anna Olegovna

    2013-09-01

    Full Text Available In the article the main processes of hydrodynamic regime of aeration tank are observed: the formation and ascent of air bubbles during aeration and motion of the water-sludge mixture. The formulas for determining the potential speed of an air bubble during aeration and energy of the water-sludge stream motion are presented. The investigation of interaction mechanism of purified waste water and air bubbles in the process of aeration in relation to the flow dynamics is poorly explored and challenging. Interaction of energetic components of the bubbles flow during aeration and uniform stream motion in the aerotank is the part of mass transfer and diffusion. The increase in total energy of the system by means of summing and raising potentials of the stream and bubbles speed can lead to increasing the purification effect, that means speeding up the diffusion processes.

  2. Phytoremediation of industrial effluent containing azo dye by model up-flow constructed wetland

    Institute of Scientific and Technical Information of China (English)

    S.A.Ong; K.Uchiyama; D.Inadama; Y.Ishida; K.Yamagiwa

    2009-01-01

    This study assessed the treatment of azo dye Acid Orange 7(AO7)containing wastewater by laboratory-scale up-flow constructed wetland(UFCW)with and without supplementary aeration.The supplementary aeration could effectively control the ratio of anaerobic and aerobic zones in the UFCW reactor.The results dearly show the supplementary aeration boosted the biodegradation of organic pollutants and mineralization of intermediate aromatic amines formed by AO7 degradation.

  3. Velocity and energy relaxation in two-phase flows

    CERN Document Server

    Meyapin, Yannick; Gisclon, Marguerite

    2009-01-01

    In the present study we investigate analytically the process of velocity and energy relaxation in two-phase flows. We begin our exposition by considering the so-called six equations two-phase model [Ishii1975, Rovarch2006]. This model assumes each phase to possess its own velocity and energy variables. Despite recent advances, the six equations model remains computationally expensive for many practical applications. Moreover, its advection operator may be non-hyperbolic which poses additional theoretical difficulties to construct robust numerical schemes |Ghidaglia et al, 2001]. In order to simplify this system, we complete momentum and energy conservation equations by relaxation terms. When relaxation characteristic time tends to zero, velocities and energies are constrained to tend to common values for both phases. As a result, we obtain a simple two-phase model which was recently proposed for simulation of violent aerated flows [Dias et al, 2010]. The preservation of invariant regions and incompressible li...

  4. Distinguished hyperbolic trajectories in time-dependent fluid flows: analytical and computational approach for velocity fields defined as data sets

    Directory of Open Access Journals (Sweden)

    K. Ide

    2002-01-01

    Full Text Available In this paper we develop analytical and numerical methods for finding special hyperbolic trajectories that govern geometry of Lagrangian structures in time-dependent vector fields. The vector fields (or velocity fields may have arbitrary time dependence and be realized only as data sets over finite time intervals, where space and time are discretized. While the notion of a hyperbolic trajectory is central to dynamical systems theory, much of the theoretical developments for Lagrangian transport proceed under the assumption that such a special hyperbolic trajectory exists. This brings in new mathematical issues that must be addressed in order for Lagrangian transport theory to be applicable in practice, i.e. how to determine whether or not such a trajectory exists and, if it does exist, how to identify it in a sequence of instantaneous velocity fields. We address these issues by developing the notion of a distinguished hyperbolic trajectory (DHT. We develop an existence criteria for certain classes of DHTs in general time-dependent velocity fields, based on the time evolution of Eulerian structures that are observed in individual instantaneous fields over the entire time interval of the data set. We demonstrate the concept of DHTs in inhomogeneous (or "forced" time-dependent linear systems and develop a theory and analytical formula for computing DHTs. Throughout this work the notion of linearization is very important. This is not surprising since hyperbolicity is a "linearized" notion. To extend the analytical formula to more general nonlinear time-dependent velocity fields, we develop a series of coordinate transforms including a type of linearization that is not typically used in dynamical systems theory. We refer to it as Eulerian linearization, which is related to the frame independence of DHTs, as opposed to the Lagrangian linearization, which is typical in dynamical systems theory, which is used in the computation of Lyapunov exponents. We

  5. Analytical solutions of actin-retrograde-flow in a circular stationary cell: a mechanical point of view.

    Science.gov (United States)

    Ghasemi, V A; Firoozabadi, B; Saidi, M S

    2014-03-01

    The network of actin filaments in the lamellipodium (LP) of stationary and migrating cells flows in a retrograde direction, from the membrane periphery toward the cell nucleus. We have theoretically studied this phenomenon in the circular stationary (fully spread) cells. Adopting a continuum view on the LP actin network, new closed-form solutions are provided for the actin-retrograde-flow (ARF) in a polar coordinate system. Due to discrepancy in the mechanical models of the actin network in the ARF regime, solutions are provided for both assumptions of solid and fluid behavior. Other involved phenomena, including polymerizing machine at the membrane periphery, cytosol drag, adhesion friction, and membrane tension, are also discussed to provide an overall quantitative view on this problem.

  6. ANALYTICAL AND NUMERICAL ANALYSIS OF MHD BOUNDARY-LAYER FLOW OF AN INCOMPRESSIBLE UPPER-CONVECTED MAXWELLFLUID

    Directory of Open Access Journals (Sweden)

    M. RAHIMI EOSBOEE,

    2010-12-01

    Full Text Available In this study magnetohydrodynamics (MHD boundary layer flow of an upper-convected Maxwell fluid has been investigated. Similarity transformation has been used to reduce the governing differential equations into an ordinary non-linear differential equation. homotopy perturbation Method (HPM has applied to solve this developed nonlinear equation. In this article firstly, the basic idea of the HPM for solving nonlinear differential equations is briefly ntroduced and then it is employed to derive solution of nonlinear governing equation of MHD boundary layer flow with highly nonlinear term. The obtained results from HPM have been compared with numerical Boundary Value problem Method (BVP to verify the accuracy of the proposed method. The effects of the Hartman number (M and Deborah number (β for various conditions have been shown through graphs.

  7. Penetrating Annulus Fibrosus Injuries Affect Dynamic Compressive Behaviors of the Intervertebral Disc Via Altered Fluid Flow: An Analytical Interpretation

    OpenAIRE

    Michalek, Arthur J.; Iatridis, James C.

    2011-01-01

    Extensive experimental work on the effects of penetrating annular injuries indicated that large injuries impact axial compressive properties of small animal intervertebral discs, yet there is some disagreement regarding the sensitivity of mechanical tests to small injury sizes. In order to understand the mechanism of injury size sensitivity, this study proposed a simple one dimensional model coupling elastic deformations in the annulus with fluid flow into and out of the nucleus through both ...

  8. Two-phase flow properties in aperture-based fractures under normal deformation conditions: Analytical approach and numerical simulation

    Science.gov (United States)

    Ye, Zuyang; Liu, Hui-Hai; Jiang, Qinghui; Liu, Yanzhang; Cheng, Aiping

    2017-02-01

    A systematic method has been proposed to estimate the two-phase flow properties of horizontal fractures under normal deformation condition. Based on Gaussian aperture distributions and the assumption of local parallel plate model, a simple model was obtained in closed form to predict the capillary pressure-saturation relationships for both wetting and non-wetting phases. Three conceptual models were also developed to characterize the relative permeability behaviors. In order to investigate the effect of normal deformation on two-phase flow properties, the normal deformation could be represented with the maximum void space closure on the basis of penetration model. A rigorous successive random addition (SRA) method was used to generate the aperture-based fractures and a numerical approach based on invasion percolation (IP) model was employed to model capillary-dominated displacements between wetting and non-wetting phases. The proposed models were partially verified by a laboratory dataset and numerical calculations without consideration of deformation. Under large normal deformations, it was found that the macroscopic model is in better agreement with simulated observations. The simulation results demonstrated that the two-phase flow properties including the relationships between capillary pressure, relative permeability and saturation, phase interference, phase structures, residual-saturation-rated parameters and tortuosity factor, were highly sensitive to the spatial correlation of aperture distribution and normal deformation.

  9. An analytical model for flow induced by a constant-head pumping in a leaky unconfined aquifer system with considering unsaturated flow

    Science.gov (United States)

    Lin, Ye-Chen; Li, Ming-Hsu; Yeh, Hund-Der

    2017-09-01

    A new mathematical model is developed to describe the flow in response to a constant-head pumping (or constant-head test, CHT) in a leaky unconfined aquifer system of infinite lateral extent with considering unsaturated flow. The model consists of an unsaturated zone on the top, an unconfined aquifer in the middle, and a second aquifer (aquitard) at the bottom. The unsaturated flow is described by Richard's equation, and the flows in unconfined aquifer and second layer are governed by the groundwater flow equation. The well partially penetrates the unconfined aquifer with a constant head in the well due to CHT. The governing equations of the model are linearized by the perturbation method and Gardner's exponential model is adopted to describe the soil retention curves. The solution of the model for drawdown distribution is obtained by applying the methods of Laplace transform and Weber transform. Then the solution for the wellbore flowrate is derived from the drawdown solution with Darcy's law. The issue of the equivalence of normalized drawdown predicted by the present solution for constant-head pumping and Tartakovsky and Neuman's (2007) solution for constant-rate pumping is discussed. On the basis of the wellbore flowrate solution, the results of the sensitivity analysis indicate that the wellbore flowrate is very sensitive to the changes in the radial hydraulic conductivity and the thickness of the saturated zone. Moreover, the results predicted from the present wellbore flowrate solution indicate that this new solution can reduce to Chang's et al. (2010a) solution for homogenous aquifers when the dimensionless unsaturated exponent approaches 100. The unsaturated zone can be considered as infinite extent in the vertical direction if the thickness ratio of the unsaturated zone to the unconfined aquifer is equal to or greater than one. As for the leakage effect, it can be ignored when the vertical hydraulic conductivity ratio (i.e., the vertical hydraulic

  10. Exact Analytical Solution of the Peristaltic Nanofluids Flow in an Asymmetric Channel with Flexible Walls and Slip Condition: Application to the Cancer Treatment

    Directory of Open Access Journals (Sweden)

    Abdelhalim Ebaid

    2013-01-01

    Full Text Available In the cancer treatment, magnetic nanoparticles are injected into the blood vessel nearest to the cancer’s tissues. The dynamic of these nanoparticles occurs under the action of the peristaltic waves generated on the flexible walls of the blood vessel. Studying such nanofluid flow under this action is therefore useful in treating tissues of the cancer. In this paper, the mathematical model describing the slip peristaltic flow of nanofluid was analytically investigated. Exact expressions were deduced for the temperature distribution and nano-particle concentration. In addition, the effects of the slip, thermophoresis, and Brownian motion parameters on the temperature and nano-particle concentration profiles were discussed and further compared with other approximate results in the literatures. In particular, these results have been obtained at the same values of the physical examined parameters that was considered in Akbar et al., “Peristaltic flow of a nanofluid with slip effects,” 2012. The results reveal that remarkable differences are detected between the exact current results and those approximately obtained in the literatures for behaviour of the temperature profile and nano-particles concentration. Accordingly, the current analysis and results are considered as optimal and therefore may be taken as a base for any future comparisons.

  11. High-beta analytic equilibria in circular, elliptical, and D-shaped large aspect ratio axisymmetric configurations with poloidal and toroidal flows

    Science.gov (United States)

    López, O. E.; Guazzotto, L.

    2017-03-01

    The Grad-Shafranov-Bernoulli system of equations is a single fluid magnetohydrodynamical description of axisymmetric equilibria with mass flows. Using a variational perturbative approach [E. Hameiri, Phys. Plasmas 20, 024504 (2013)], analytic approximations for high-beta equilibria in circular, elliptical, and D-shaped cross sections in the high aspect ratio approximation are found, which include finite toroidal and poloidal flows. Assuming a polynomial dependence of the free functions on the poloidal flux, the equilibrium problem is reduced to an inhomogeneous Helmholtz partial differential equation (PDE) subject to homogeneous Dirichlet conditions. An application of the Green's function method leads to a closed form for the circular solution and to a series solution in terms of Mathieu functions for the elliptical case, which is valid for arbitrary elongations. To extend the elliptical solution to a D-shaped domain, a boundary perturbation in terms of the triangularity is used. A comparison with the code FLOW [L. Guazzotto et al., Phys. Plasmas 11(2), 604-614 (2004)] is presented for relevant scenarios.

  12. PREPARATION OF ULTRA-LOW VOLUME WEIGHT AUTOCLAVED AERATED CONCRETE

    Directory of Open Access Journals (Sweden)

    Ondrej Koutny

    2016-12-01

    Full Text Available Autoclaved aerated concrete is a modern construction material that gains its popularity especially due to its thermal insulation performance resulting from low volume weight and porous structure with sufficient mechanical strength. Nowadays, there are attempts to use this material for thermal insulation purposes and to replace current systems, which have many disadvantages, mainly concerning durability. The key for improvement of thermal insulation properties is therefore obtaining a material based on autoclaved aerated concrete with extremely low volume weight (below 200 kg/m ³ ensuring good thermal isolation properties, but with sufficient mechanical properties to allow easy manipulation. This material can be prepared by foaming very fine powder materials such as silica fume or very finely ground sand. This paper deals with the possibilities of preparation and summarizes the basic requirements for successful preparation of such a material.

  13. Aeration of large-scale municipal wastewater treatment plants: state of the art.

    Science.gov (United States)

    Rosso, Diego; Stenstrom, Michael K; Larson, Lory E

    2008-01-01

    Aeration is the most energy-intensive operation in wastewater treatment, amounting to 45-75% of plant energy costs. Fine-pore diffusers are today almost ubiquitous in municipal wastewater aeration, due to their advantageous aeration efficiency (mass of oxygen transferred per unit energy required). Nevertheless, older municipal treatment facilities and many industrial treatment plants are still equipped with coarse-bubble or surface aerators. Fine-pore diffusers are subject to two major disadvantages: a) fouling, if not cleaned periodically; b) decrease in oxygen transfer efficiency caused by dissolved surfactants. Coarse-bubble and surface aerators are typically not subject to the traditional problems affecting fine-pore diffusers. Nonetheless, they achieve oxygen transfer at the expense of increased energy intensity. The increased biomass concentration associated with high mean cell retention time (MCRT) operations has a beneficial effect on aeration. Nutrient-removing selectors are able to further increase aeration efficiency, as they sorb and utilize the readily available substrate which otherwise would accumulate at bubble surfaces and dramatically decrease aeration efficiency. We summarise here our 30-year long experience in aeration research, and results obtained with clean- and process-water tests are used to show the beneficial effects of high MCRT operations, the beneficial effect of selectors, and the decline of aeration efficiency due to dissolved surfactants. Copyright IWA Publishing 2008.

  14. Effects of aeration frequency on leachate quality and waste in simulated hybrid bioreactor landfills.

    Science.gov (United States)

    Ko, Jae Hac; Ma, Zeyu; Jin, Xiao; Xu, Qiyong

    2016-12-01

    Research has been conducted to investigate the effects of daily aeration frequency on leachate quality and waste settlement in simulated hybrid landfill bioreactors. Four laboratory-scale reactors were constructed and operated for about 10 months to simulate different bioreactor operations, including one anaerobic bioreactor and three hybrid bioreactors with different aeration frequencies (one, two, and four times per day). Chemical oxygen demand (COD) and biochemical oxygen demand (BOD5) reduced more than 96% of the initial concentrations in all aerated bioreactors. The differences of COD and BOD5 reductions among tested aeration frequencies were relatively small. For ammonia nitrogen, the higher aeration frequency (two or four times per day) resulted in the quicker reduction. Overall, the concentrations of heavy metals (Cr, Co, Cu, Mn, Ni, and Zn) decreased over time except Cd and Pb. The reduction of redox-sensitive metal concentrations (Mn, Co, Ni, and Cu) was greater in aerated bioreactors than in anaerobic bioreactor. Settlement of municipal solid waste (MSW) was enhanced with higher frequency of aeration events (four times per day). In recent years, hybird bioreactor landfill technology has gained a lot of attention. Appropriate aeration rate is crucial for hybrid bioreactor operation, but few studies have been done and different results were obtained. Research was conducted to investigate the effects of daily aeration frequency on leachate quality and waste settlement. Results indicated that aeration can effectively accelerate waste stabilization and remove organic carbon concentration and total nitrogen in the leachate.

  15. The effect of cohesive forces on the fluidization of aeratable powders

    Energy Technology Data Exchange (ETDEWEB)

    Galvin, Janine F.; Benyahia, Sofiane

    2014-01-01

    The effects of cohesive forces of van der Waals type in the fluidization/defluidization of aeratable type A powders in the Geldart classification are numerically investigated. The effects of friction and particle-size distribution (PSD) on some design-significant parameters, such as minimum fluidization and bubbling velocities, are also investigated. For these types of particles, cohesive forces are observed as necessary to fully exhibit the role friction plays in commonly observed phenomena, such as pressure overshoot and hysteresis around minimum fluidization. This study also shows that a full-experimental PSD consisting of a dozen particle sizes may be sufficiently represented by a few particle diameters. Reducing the number of particle types may benefit the continuum approach, which is based on the kinetic theory of granular flow, by reducing computational expense, while still maintaining the accuracy of the predictions.

  16. Treatment of Slightly Polluted Wastewater in an Oil Refinery Using a Biological Aerated Filter Process

    Institute of Scientific and Technical Information of China (English)

    XIE Wenyu; ZHONG Li; CHEN Jianjun

    2007-01-01

    The slightly polluted wastewater from oil refinery contains some COD, oil pollutants and suspended solids (SS). A small-scale fixed film biological aerated filter (BAF) process was used to treat the wastewater. The influences of hydraulic retention time (HRT), air/water volume flow ratio and backwashing cycle on treatment efficiencies were investigated. The wastewater was treated by the BAF process under optimal conditions: the HRT of backwashing cycle of every 4-7 days. The results showed that the average removal efficiency of COD, oil pollutants and SS was 84.5%, 94.0% and 83.4%, respectively. And the average effluent concentration of COD, oil pollutants and SS was 12.5, 0.27, 14.5the BAF process is a suitable and highly efficient method to treat the wastewater.

  17. Development of a novel membrane aerated hollow-fiber microbioreactor.

    Science.gov (United States)

    Villain, Louis; Meyer, Lina; Kroll, Stephen; Beutel, Sascha; Scheper, Thomas

    2008-01-01

    A new challenge in biotechnological processes is the development of flexible bioprocessing platforms, allowing strain selection, facilitating scale-up and integrating separation steps. Miniaturization of such a cultivation system allows parallel use and the saving of resources but makes the supply of oxygen to the cells difficult. In this work we present a membrane aerated hollow-fiber microbioreactor (HFMBR) which consists of an acrylic glass module equipped with two different types of membrane fibers. Fibers of polyethersulfone and polyvinyldifluoride were used for substrate and oxygen supply, respectively. Cultivation of E. coli as model organism and production of His-tagged GFP were carried out in the extracapillary space of the membrane aerated HFMBR and compared with cultivations in shaking flask which are commonly used for screening experiments. The measurement of the oxygen transfer capacity and the online monitoring of the dissolved oxygen during the cultivation were performed using a fiber optic oxygen sensor. Online measurement of the optical density was also integrated to the bioreactor. Due to efficient oxygen transfer, a better cell growth than in the shaking flask experiments was achieved, while no negative influence on the GFP productivity was observed in the membrane aerated bioreactor. Thus the feasibility of a future integrated downstreaming could also be demonstrated.

  18. Soil aeration status in a lowland wet grassland

    Science.gov (United States)

    Barber, K. R.; Leeds-Harrison, P. B.; Lawson, C. S.; Gowing, D. J. G.

    2004-02-01

    The maintenance or development of plant community diversity in species-rich wet grasslands has been a focus of water management considerations in the UK for the past 20 years. Much attention has been given to the control of water levels in the ditch systems within these wet grassland systems. In this paper we report measurements of aeration status and water-table fluctuation made on a peat soil site at Tadham Moor in Somerset, UK, where water management has focused on the maintenance of wet conditions that often result in flooding in winter and wet soil conditions in the spring and summer. Measurement and modelling of the water-table fluctuation indicates the possibility of variability in the aeration of the root environment and anoxic conditions for much of the winter period and for part of the spring and summer. We have used water content and redox potential measurements to characterize the aeration status of the peat soil. We find that air-filled porosity is related to water-table depth in these situations. Redox potentials in the spring were generally found to be low, implying a reducing condition for nitrate and iron. A significant relationship (p < 0.01) between redox potential and water-table depth exists for data measured at 0.1 m depth, but no relationship could be found for data from 0.4 m depth.

  19. Analytic model of the effect of poly-Gaussian roughness on rarefied gas flow near the surface

    Science.gov (United States)

    Aksenova, Olga A.; Khalidov, Iskander A.

    2016-11-01

    The dependence of the macro-parameters of the flow on surface roughness of the walls and on geometrical shape of the surface is investigated asymptotically and numerically in a rarefied gas molecular flow at high Knudsen numbers. Surface roughness is approximated in statistical simulation by the model of poly-Gaussian (with probability density as the mixture of Gaussian densities [1]) random process. Substantial difference is detected for considered models of the roughness (Gaussian, poly-Gaussian and simple models applied by other researchers), as well in asymptotical expressions [3], as in numerical results. For instance, the influence of surface roughness on momentum and energy exchange coefficients increases noticeably for poly-Gaussian model compared to Gaussian one (although the main properties of poly-Gaussian random processes and fields are similar to corresponding properties of Gaussian processes and fields). Main advantage of the model is based on relative simple relations between the parameters of the model and the basic statistical characteristics of random field. Considered statistical approach permits to apply not only diffuse-specular model of the local scattering function V0 of reflected gas atoms, but also Cercignani-Lampis scattering kernel or phenomenological models of scattering function. Thus, the comparison between poly-Gaussian and Gaussian models shows more significant effect of roughness in aerodynamic values for poly-Gaussian model.

  20. Analytical studies on a new lattice hydrodynamic traffic flow model with consideration of traffic current cooperation among three consecutive sites

    Science.gov (United States)

    Li, Zhipeng; Zhong, Chenjie; Chen, Lizhu; Xu, Shangzhi; Qian, Yeqing

    2016-09-01

    In this paper, the original lattice hydrodynamic model of traffic flow is extended to take into account the traffic current cooperation among three consecutive sites. The basic idea of the new consideration is that the cooperative traffic current of the considered site is determined by the traffic currents of the site itself, the immediately preceding site and the immediately following one. The stability criterion of the extended model is obtained by applying the linear stability analysis. The result reveals the traffic current cooperation of the immediately preceding site is positive correlation with the stability of traffic system, while negative correlation is found between the traffic stability and the traffic current cooperation of the nearest follow site. To describe the phase transition, the modified KdV equation near the critical point is derived by using the reductive perturbation method, with obtaining the dependence of the propagation kink solution for traffic jams on the traffic current cooperation among three consecutive sites. The direct numerical are conducted to verify the results of theoretical analysis, and explore the effects of the traffic current cooperation on the traffic flux of the vehicle flow system.

  1. Analytic Approximate Solutions for MHD Boundary-Layer Viscoelastic Fluid Flow over Continuously Moving Stretching Surface by Homotopy Analysis Method with Two Auxiliary Parameters

    Directory of Open Access Journals (Sweden)

    M. M. Rashidi

    2012-01-01

    Full Text Available In this study, a steady, incompressible, and laminar-free convective flow of a two-dimensional electrically conducting viscoelastic fluid over a moving stretching surface through a porous medium is considered. The boundary-layer equations are derived by considering Boussinesq and boundary-layer approximations. The nonlinear ordinary differential equations for the momentum and energy equations are obtained and solved analytically by using homotopy analysis method (HAM with two auxiliary parameters for two classes of visco-elastic fluid (Walters’ liquid B and second-grade fluid. It is clear that by the use of second auxiliary parameter, the straight line region in ℏ-curve increases and the convergence accelerates. This research is performed by considering two different boundary conditions: (a prescribed surface temperature (PST and (b prescribed heat flux (PHF. The effect of involved parameters on velocity and temperature is investigated.

  2. Analytical and Numerical Studies of a Steam Ejector on the Effect of Nozzle Exit Position and Suction Chamber Angle to Fluid Flow and System Performance

    Directory of Open Access Journals (Sweden)

    A. S. Ramesh

    2017-01-01

    Full Text Available Nozzle exit position [NXP] plays a vital role in the performance of the ejector, but its values are specified in a range for the required operating condition. In this study instead of the range of values, a specific value, named as entrainment diameter is developed and its effect on the performance of the ejector is studied for several combinations of suction chamber angle using numerical method. The effect of the condenser and boiler pressures on the performance of the ejector are also studied to ensure the off-design operating conditions. The entrainment diameter of an ejector is derived analytically by solving one dimensional compressible fluid flow equations using MATLAB. To study the effect of entrainment diameter on the performance of the ejector, CFD technique is employed. Analytical and numerical results are validated with experimental data available in the previous studies. For 7 kW refrigeration capacity, it is inferred that the suction chamber angle of 18° and the corresponding entrainment diameter 90.8 mm with the NXP of 23.62 mm yield the maximum entrainment ratio. The study predicts that the performance of the ejector is highly influenced by the pressure increment at the exit of the nozzle, while the suction chamber angle is between 12° to 21°.

  3. Assessment of analytical and experimental techniques utilized in conducting plume technology tests 575 and 593. [exhaust flow simulation (wind tunnel tests) of scale model Space Shuttle Orbiter

    Science.gov (United States)

    Baker, L. R.; Sulyma, P. R.; Tevepaugh, J. A.; Penny, M. M.

    1976-01-01

    Since exhaust plumes affect vehicle base environment (pressure and heat loads) and the orbiter vehicle aerodynamic control surface effectiveness, an intensive program involving detailed analytical and experimental investigations of the exhaust plume/vehicle interaction was undertaken as a pertinent part of the overall space shuttle development program. The program, called the Plume Technology program, has as its objective the determination of the criteria for simulating rocket engine (in particular, space shuttle propulsion system) plume-induced aerodynamic effects in a wind tunnel environment. The comprehensive experimental program was conducted using test facilities at NASA's Marshall Space Flight Center and Ames Research Center. A post-test examination of some of the experimental results obtained from NASA-MSFC's 14 x 14-inch trisonic wind tunnel is presented. A description is given of the test facility, simulant gas supply system, nozzle hardware, test procedure and test matrix. Analysis of exhaust plume flow fields and comparison of analytical and experimental exhaust plume data are presented.

  4. Predictability of tracer dilution in large open channel flows: Analytical solution for the coefficient of variation of the depth-averaged concentration

    Science.gov (United States)

    Pannone, Marilena

    2014-03-01

    A large-time analytical solution is proposed for the spatial variance and coefficient of variation of the depth-averaged concentration due to instantaneous, cross sectionally uniform solute sources in pseudorectangular open channel flows. The mathematical approach is based on the use of the Green functions and on the Fourier decomposition of the depth-averaged velocities, coupled with the method of the images. The variance spatial trend is characterized by a minimum at the center of the mass and two mobile, decaying symmetrical peaks which, at very large times, are located at the inflexion points of the average Gaussian distribution. The coefficient of variation, which provides an estimate of the expected percentage deviation of the depth-averaged point concentrations about the section-average, exhibits a minimum at the center which decays like t-1 and only depends on the river diffusive time scale. The defect of cross-sectional mixing quickly increases with the distance from the center, and almost linearly at large times. Accurate numerical Lagrangian simulations were performed to validate the analytical results in preasymptotic and asymptotic conditions, referring to a particularly representative sample case for which cross-sectional depth and velocity measurements were known from a field survey. In addition, in order to discuss the practical usefulness of computing large-time concentration spatial moments in river flows, and resorting to directly measured input data, the order of magnitude of section-averaged concentrations and corresponding coefficients of variation was estimated in field conditions and for hypothetical contamination scenarios, considering a unit normalized mass impulsively injected across the transverse section of 81 U.S. rivers.

  5. Compressive loading at the end plate directly regulates flow and deformation of the basivertebral vein: an analytical study

    Directory of Open Access Journals (Sweden)

    Chen Hsiang-Ho

    2006-12-01

    Full Text Available Abstract Background Metastatic diseases and infections frequently involve the spine. This is the result of seeding of the vertebral body by tumor cells or bacteria delivered by venous blood from Batson's plexus, which is hypothesized to enter the vertebral body via the epidural veins. Isolated spinal segments deform significantly at the bony end plate when under compression. This deformation could cause a volume change of the vertebral body and may be accompanied by retrograde flow of venous blood. To date, this process has not been investigated quantitatively. The purpose of this study was to determine the volume changes of the vertebral body and basivertebral vein for a vertebral body under compression. Methods A three-dimensional finite element mesh model of the L4 segment with both adjacent discs was modified from a 3-D computed tomography scan image. An octagon representing the basivertebral vein was introduced into the center of the vertebral body in the model. Four compressive orientations (1500 N were applied on the top disc. The volume change of the vertebral body model and the basivertebral vein were then computed. Results The volume change of the vertebral body was about 0.1 cm3 (16.3% of the basivertebral vein for the four loading conditions. The maximum cross-sectional area reductions of the basivertebral vein and volume reduction were 1.54% and 1.02%, for uniform compression. Conclusion Our study quantified the small but significant volume change of a modeled vertebral body and cross-sectional areas and that of the basivertebral vein, due to the inward bulging of the end plate under compression. This volume change could initiate the reverse flow of blood from the epidural venous system and cause seeding of tumors or bacterial cells.

  6. Effects of aeration position on organics, nitrogen and phosphorus removal in combined oxidation pond-constructed wetland systems.

    Science.gov (United States)

    Wang, Xiaoou; Tian, Yimei; Zhao, Xinhua; Peng, Sen; Wu, Qing; Yan, Lijian

    2015-12-01

    Given that few studies investigated the effects of aeration position (AP) on the performance of aerated constructed wetlands, the aim of this study was to evaluate the effects of AP on organics, nitrogen and phosphorus removal in lab-scale combined oxidation pond-constructed wetland (OP-CW) systems. Results showed that middle aeration allowed the CW to possess more uniform oxygen distribution and to achieve greater removals of COD and NH3-N, while the CW under bottom aeration and surface aeration demonstrated more distinct stratification of oxygen distribution and surface aeration brought about better TN removal capacity for the OP-CW system. However, no significant influence of artificial aeration or AP on TP removal was observed. Overall, AP could significantly affect the spatial distribution of dissolved oxygen by influencing the oxygen diffusion paths in aerated CWs, thereby influencing the removal of pollutants, especially organics and nitrogen, which offers a reference for the design of aerated CWs.

  7. PENGGUNAAN MEMBRAN SERAT BERONGGA SEBAGAI AERATOR DALAM SISTEM KULTIVASI UNTUK MENINGKATKAN PRODUKSI BIOMASSA DAN BIOFIKSASI CO2 DARI Chlorella vulgaris

    Directory of Open Access Journals (Sweden)

    D Dianursanti

    2015-06-01

    determining increase in biomass production of Chlorella. The higher the value of KLa, isthe better the process of mass transfer of CO2would be, but also the greater shear stress on algae would be. By using hollow fiber membrane as aerators, shear stress on the algae problem can be avoided. With a very small pore diameter, the membrane may provide the flow rate and the mass transfer of CO2 in the optimal culture without shear stress effect on algae. Thus the use of these membranes may result in better productivity and Chlorella may enhance the ability of CO2 fixation during the cultivation. The use of hollow fiber membrane as aerators has shown to increase the production of biomass C. vulgaris by 27.2%.

  8. A meta-analytic review of life cycle assessment and flow analyses studies of palm oil biodiesel.

    Science.gov (United States)

    Manik, Yosef; Halog, Anthony

    2013-01-01

    This work reviews and performs a meta-analysis of the recent life cycle assessment and flow analyses studies palm oil biodiesel. The best available data and information are extracted, summarized, and discussed. Most studies found palm oil biodiesel would produce positive energy balance with an energy ratio between 2.27 and 4.81, and with a net energy production of 112 GJ ha(-1) y(-1). With the exception of a few studies, most conclude that palm oil biodiesel is a net emitter of greenhouse gases (GHG). The origin of oil palm plantation (planted area) is the foremost determinant of GHG emissions and C payback time (CPBT). Converting peatland forest results in GHG emissions up to 60 tons CO(2) equivalent (eq) ha(-1) y(-1) leading to 420 years of CPBT. In contrast, converting degraded land or grassland for plantation can positively offset the system to become a net sequester of 5 tons CO(2) eq ha(-1) y(-1). Few studies have discussed cradle-to-grave environmental impacts such as acidification, eutrophication, toxicity, and biodiversity, which open opportunity for further studies.

  9. Penetrating annulus fibrosus injuries affect dynamic compressive behaviors of the intervertebral disc via altered fluid flow: an analytical interpretation.

    Science.gov (United States)

    Michalek, Arthur J; Iatridis, James C

    2011-08-01

    Extensive experimental work on the effects of penetrating annular injuries indicated that large injuries impact axial compressive properties of small animal intervertebral discs, yet there is some disagreement regarding the sensitivity of mechanical tests to small injury sizes. In order to understand the mechanism of injury size sensitivity, this study proposed a simple one dimensional model coupling elastic deformations in the annulus with fluid flow into and out of the nucleus through both porous boundaries and through a penetrating annular injury. The model was evaluated numerically in dynamic compression with parameters obtained by fitting the solution to experimental stress-relaxation data. The model predicted low sensitivity of mechanical changes to injury diameter at both small and large sizes (as measured by low and high ratios of injury diameter to annulus thickness), with a narrow range of high sensitivity in between. The size at which axial mechanics were most sensitive to injury size (i.e., critical injury size) increased with loading frequency. This study provides a quantitative hypothetical model of how penetrating annulus fibrosus injuries in discs with a gelatinous nucleus pulposus may alter disc mechanics by changing nucleus pulposus fluid pressurization through introduction of a new fluid transport pathway though the annulus. This model also explains how puncture-induced biomechanical changes depend on both injury size and test protocol.

  10. Aeration-Induced Changes in Temperature and Nitrogen Dynamics in a Dimictic Lake.

    Science.gov (United States)

    Holmroos, Heidi; Horppila, Jukka; Laakso, Sanna; Niemistö, Juha; Hietanen, Susanna

    2016-07-01

    Low levels of oxygen (O) in the hypolimnion layer of lakes are harmful to benthic animals and fish; they may also adversely affect nutrient cycles. Artificial aeration is often used in lake management to counteract these problems, but the effects of aeration on nitrogen (N) cycling are not known. We studied the effects of hypolimnetic aeration on N dynamics and temperature in a eutrophic lake by comparing continuous and pulsed aeration with a nonaerated station. Aeration decreased the accumulation of NH-N deep in the lake (20-33 m) by supplying O for nitrification, which in turn provided substrate for denitrification and promoted N removal. Aeration also increased the temperature in the hypolimnion. Denitrification rate was highest in the nonaerated deep areas (average, 7.62 mg N m d) due to very high rates during spring turnover of the water column, demonstrating that natural turnover provides O for nitrification. During stratification, denitrification was highest at the continuously aerated station (4.06 mg N m d) and lowest at the nonaerated station (3.02 mg N m d). At the periodically aerated station, aeration pauses did not restrict the increase in temperature but resulted in accumulation of NH-N and decreased the contribution of denitrification as a nitrate reduction process. Our findings demonstrate that hypolimnetic aeration can substantially affect N cycling in lakes and that the effect depends on the aeration strategy. Because N is one of the main nutrients controlling eutrophication, the effects of aeration methods on N removal should be considered as part of strategies to manage water quality in lakes.

  11. Experience of drilling wells using pump-compressor unit to inject aerated fluid

    Energy Technology Data Exchange (ETDEWEB)

    Oleynik, S.P.; Beley, I.V.; Lopatin, Yu.S.; Pytel, S.P.; Vasilak, I.I.; Yushkevich, V.I.

    1979-01-01

    Results are described from drilling wells with flushing by highly aerated clay fluid with the help of a UNGA unit which includes pumps and compressors of the drilling unit UBSh-1 which permits injection of an aerated mixture under pressures considerably exceeding the pressure of its formation. Qualitative and technical-economic advantages of drilling with flushing by aerated solutions with the use of a unit for injecting gas-liquid agents are presented.

  12. Novel analytical approach to monitoring advanced glycosylation end products in human serum with on-line spectrophotometric and spectrofluorometric detection in a flow system.

    Science.gov (United States)

    Wróbel, K; Wróbel, K; Garay-Sevilla, M E; Nava, L E; Malacara, J M

    1997-09-01

    We proposed a simple analytical procedure for measurement of serum advanced glycosylation end products (AGEs) based on simultaneous detection of low-molecular-mass peptides and AGEs with a flow system and two detectors connected on-line: spectrophotometric for peptides (lambda = 280 nm) and spectrofluorometric for AGEs (lambda ex = 247 nm, lambda em = 440 nm). Sample pretreatment was carried out in microcentrifuge tubes: Serum (20 microL) was deproteinized with trichloroacetic acid (480 microL, 0.15 mol/L) and lipids were extracted with chloroform (100 microL). Twenty microliters of the filtered aqueous layer was injected to the flow system and the relation between fluorescence and absorption signals was measured. A peptide-derived AGE calibrator was used for calibration. Within-day and between-day CVs were 6.7% and 9.1%, respectively, at an AGE concentration corresponding approximately to that in healthy individuals. Mean results (+/-SD) in 10 healthy individuals were 10.1% +/- 1.0%, in 21 patients with diabetes without complications 18.0% +/- 6.2%, in 25 patients with complications 24.1% +/- 15.4%, and in 12 diabetic patients in end-stage renal disease 92% +/- 30%. Comparison with an ELISA procedure (x, in arbitrary units/L) yields a regression equation y = 0.713x + 1.24 (Sy [symbol: see text] x = 6777, r = 0.8477, n = 41).

  13. Analytical applications of glassy carbon electrodes modified with multi-wall carbon nanotubes dispersed in polyethylenimine as detectors in flow systems.

    Science.gov (United States)

    Sánchez Arribas, Alberto; Bermejo, Esperanza; Chicharro, Manuel; Zapardiel, Antonio; Luque, Guillermina L; Ferreyra, Nancy F; Rivas, Gustavo A

    2007-07-23

    This work reports the advantages of using glassy carbon electrodes (GCEs) modified with multi-wall carbon nanotubes (CNT) dispersed in polyethylenimine (PEI) as detectors in flow injection and capillary electrophoresis. The presence of the dispersion of CNT in PEI at the electrode surface allows the highly sensitive and reproducible determination of hydrogen peroxide, different neurotransmitters (dopamine (D) and its metabolite dopac, epinephrine (E), norepinephrine (NE)), phenolic compounds (phenol (P), 3-chlorophenol (3-CP) and 2,3-dichlorophenol (2,3CP)) and herbicides (amitrol). Sensitivities enhancements of 150 and 140 folds compared to GCE were observed for hydrogen peroxide and amitrol, respectively. One of the most remarkable properties of the resulting electrode is the antifouling effect of the CNT/PEI layer. No passivation was observed either for successive additions (30) or continuous flow (for 30 min) of the compounds under investigation, even dopac or phenol. A critical comparison of the amperometric and voltammetric signal of these different analytes at bare- and PEI-modified glassy carbon electrodes and pyrolytic graphite electrodes is also included, demonstrating that the superior performance of CNT is mainly due to their unique electrochemical properties. Glassy carbon electrodes modified with CNT-PEI dispersion also show an excellent performance as amperometric detector in the electrophoretic separation of phenolic compounds and neurotransmitters making possible highly sensitive and reproducible determinations.

  14. An analytical two-flow model to simulate the distribution of irradiance in coastal waters with a wind-roughed surface and bottom reflectance

    Science.gov (United States)

    Ma, Wei-Ming

    1997-06-01

    An analytical two-flow model is derived from the radiative transfer equation to simulate the distribution of irradiance in coastal waters with a wind-roughed surface and bottom reflectance. The model utilizes unique boundary conditions, including the surface slope of the downwelling and upwelling irradiance as well as the influence of wind and bottom reflectance on simulated surface reflectance. The developed model provides a simple mathematical concept for understanding the irradiant light flux and associated processes in coastal or fresh water as well as turbid estuarine waters. The model is applied to data from the Banana River and coastal Atlantic Ocean water off the east coast of central Florida, USA. The two-flow irradiance model is capable of simulating realistic above-surface reflectance signatures under wind-roughened air-water surface given realistic input parameters including a specular flux conversion coefficient, absorption coefficient, backscattering coefficient, atmospheric visibility, bottom reflectance, and water depth. The root-mean-squared error of the calculated above-surface reflectances is approximately 3% in the Banana River and is less than 15% in coastal Atlantic Ocean off the east of Florida. Result of the subsurface reflectance sensitivity analysis indicates that the specular conversion coefficient is the most sensitive parameter in the model, followed by the beam attenuation coefficient, absorption coefficient, water depth, backscattering coefficient, specular irradiance, diffuse irradiance, bottom reflectance, and wind speed. On the other hand, result of the above-surface reflectance sensitivity analysis indicates that the wind speed is the most important parameter, followed by bottom reflectance, attenuation coefficient, water depth, conversion coefficient, specular irradiance, downwelling irradiance, absorption coefficient, and backscattering coefficient. Model results depend on the accuracy of these parameters to a large degree and

  15. Nitrogen-removal performance and community structure of nitrifying bacteria under different aeration modes in an oxidation ditch.

    Science.gov (United States)

    Guo, Chang-Zi; Fu, Wei; Chen, Xue-Mei; Peng, Dang-Cong; Jin, Peng-Kang

    2013-07-01

    Oxidation-ditch operation modes were simulated using sequencing batch reactors (SBRs) with alternate stirring and aerating. The nitrogen-removal efficiencies and nitrifying characteristics of two aeration modes, point aeration and step aeration, were investigated. Under the same air-supply capacity, oxygen dissolved more efficiently in the system with point aeration, forming a larger aerobic zone. The nitrifying effects were similar in point aeration and step aeration, where the average removal efficiencies of NH4(+) N were 98% and 96%, respectively. When the proportion of anoxic and oxic zones was 1, the average removal efficiencies of total nitrogen (TN) were 45% and 66% under point aeration and step aeration, respectively. Step aeration was more beneficial to both anoxic denitrification and simultaneous nitrification and denitrification (SND). The maximum specific ammonia-uptake rates (AUR) of point aeration and step aeration were 4.7 and 4.9 mg NH4(+)/(gMLVSS h), respectively, while the maximum specific nitrite-uptake rates (NUR) of the two systems were 7.4 and 5.3 mg NO2(-)-N/(gMLVSS h), respectively. The proportions of ammonia-oxidizing bacteria (AOB) to all bacteria were 5.1% under point aeration and 7.0% under step aeration, and the proportions of nitrite-oxidizing bacteria (NOB) reached 6.5% and 9.0% under point and step aeration, respectively. The dominant genera of AOB and NOB were Nitrosococcus and Nitrospira, which accounted for 90% and 91%, respectively, under point aeration, and the diversity of nitrifying bacteria was lower than under step aeration. Point aeration was selective of nitrifying bacteria. The abundance of NOB was greater than that of AOB in both of the operation modes, and complete transformation of NH4(+) N to NO3(-)-N was observed without NO2(-)-N accumulation.

  16. Violent breaking wave impacts. Part 3. Effects of scale and aeration

    DEFF Research Database (Denmark)

    Bredmose, Henrik; Bullock, G. N.; Hogg, A. J.

    2015-01-01

    . The Bagnold-Mitsuyasu scaling law for the compression of an air pocket by a piston of incompressible water is rederived and generalised to 3D air pockets of arbitrary shape. Numerical results for wall pressure, force and impulse are then presented for a flip-through impact, a low-aeration impact and a high......-aeration impact, for nine scales and five levels of initial aeration. Two of these impact types trap a pocket of air at the wall. Among the findings of the paper is that for fixed initial aeration, impact pressures from the flip-through impact broadly follow Froude scaling. This is also the case for the two...

  17. Microstructure and Properties of Silty Siliceous Crushed Stone-lime Aerated Concrete

    Institute of Scientific and Technical Information of China (English)

    WANG Qiankun; CHEN Youzhi; LI Fangxian; SUN Tao; XU Bingbo

    2006-01-01

    The clayish crushed stone was used for making aerated concrete. Through studying hydro-thermal synthesis reaction, mix ratio, gas-forming and performance analysis, Grade-B05 and Grade-B06 aerated concrete were prepared successfully. The proper mix ratio and key processing parameters were achieved. The microstructure of aerated concrete with crush stone was analyzed by means of XRD and SEM. The experimental results indicate that the hydration products are poorly crystalline C-S-H (B), tobermorite and hydrogarnet. No component of clay was found. Unreacted SiO2 can be in existence, and the structure system of aerated concrete is homogeneous and dense.

  18. [Effect of aeration intensity on the nitrogen and phosphorus removal performance of AOA membrane bioreactors].

    Science.gov (United States)

    Chen, Xiao-Yang; Xue, Zhi-Yong; Xiao, Jing-Ni; Zhang, Han-Min; Yang, Feng-Lin; Wang, Wei-Ping; Hong, Chun-Lai; Zhu, Feng-Xiang

    2011-10-01

    The ability of simultaneous phosphorus and nitrogen removal of sequencing batch membrane bioreactor run in anaerobic/oxic/ anoxic mode (AOA MBR) was examined under three aeration intensities [2.5, 3.75 and 5.0 m3 x (m2 x h)(-10]. The results showed that the averaged removals of COD were over 90% at different aeration intensities. And the higher aeration intensity was, the more ammonia nitrogen removal rate achieved. The removal rates of NH4(+) under the three aeration intensities were 84.7%, 90.6% and 93.8%, respectively. Total nitrogen removal rate increased with the increasing aeration intensity. But excessive aeration intensity reduced TN removal. The removal rates of TN under the three aeration intensities were 83.4%, 87.4% and 80.6%, respectively. Aeration intensity affected the denitrifying phosphorus ability of the AOA MBR. The ratio of denitrification phosphorus removal under the three aeration intensities were 20%, 30.2% and 26.7%, respectively.

  19. Monitoring transitory profiles of leachate humic substances in landfill aeration reactors in mesophilic and thermophilic conditions

    Energy Technology Data Exchange (ETDEWEB)

    Tong, Huanhuan [Residues and Resource Reclamation Centre, Nanyang Environment and Water Research Institute, Nanyang Technological University, 1 Cleantech Loop, CleanTech One, 637141 (Singapore); School of Civil and Environmental Engineering, Nanyang Technological University, 50 Nanyang Avenue, 639798 (Singapore); Yin, Ke; Ge, Liya; Giannis, Apostolos [Residues and Resource Reclamation Centre, Nanyang Environment and Water Research Institute, Nanyang Technological University, 1 Cleantech Loop, CleanTech One, 637141 (Singapore); Chuan, Valerie W.L. [School of Civil and Environmental Engineering, Nanyang Technological University, 50 Nanyang Avenue, 639798 (Singapore); Wang, Jing-Yuan, E-mail: JYWANG@ntu.edu.sg [Residues and Resource Reclamation Centre, Nanyang Environment and Water Research Institute, Nanyang Technological University, 1 Cleantech Loop, CleanTech One, 637141 (Singapore); School of Civil and Environmental Engineering, Nanyang Technological University, 50 Nanyang Avenue, 639798 (Singapore)

    2015-04-28

    Highlights: • Polymerization and condensation of humic substances (HS) were enhanced by aeration. • Carboxylic group was enriched in HS by aeration presenting improved hydrophilicity. • Mobility of humic acid, as a result was enhanced by aeration especially in young landfill. • Waste age plays an important role in leachate management during aeration. - Abstract: The presence of humic substances (HS) in landfill leachate is of great interest because of their structural stability and potential toxicity. This study examined the effects of temperature and waste age on the transformation of HS during in situ aeration of bioreactor landfills. By establishing aerobic conditions, dissolved organic carbon (DOC) rapidly accumulated in the bioreactor leachate. Fractional analysis showed that the elevated concentration of humic acids (HAs) was primarily responsible for the increment of leachate strength. Further structural characterization indicated that the molecular weight (MW) and aromacity of HS were enhanced by aeration in conjunction with thermophilic temperature. Interestingly, elevation of HAs concentration was not observed in the aeration reactor with a prolonged waste age, as the mobility of HAs was lowered by the high MW derived from extended waste age. Based on these results, aeration may be more favorable in aged landfills, since dissolution of HAs could be minimized by the evolution to larger MW compared to young landfills. Moreover, increased operation temperature during aeration likely offers benefits for the rapid maturation of HS.

  20. Partial nitritation ANAMMOX in submerged attached growth bioreactors with smart aeration at 20 °C.

    Science.gov (United States)

    Shannon, James M; Hauser, Lee W; Liu, Xikun; Parkin, Gene F; Mattes, Timothy E; Just, Craig L

    2015-01-01

    Submerged attached growth bioreactors (SAGBs) were operated at 20 °C for 30 weeks in smart-aerated, partial nitritation ANAMMOX mode and in a timer-controlled, cyclic aeration mode. The smart-aerated SAGBs removed 48-53% of total nitrogen (TN) compared to 45% for SAGBs with timed aeration. Low dissolved oxygen concentrations and cyclic pH patterns in the smart-aerated SAGBs suggested conditions favorable to partial nitritation ANAMMOX and stoichiometrically-derived and numerically modeled estimations attributed 63-68% and 14-44% of TN removal to partial nitritation ANAMMOX in these bioreactors, respectively. Ammonia removals of 36-67% in the smart-aerated SAGBs, with measured oxygen and organic carbon limitations, further suggest partial nitritation ANAMMOX. The smart-aerated SAGBs required substantially less aeration to achieve TN removals similar to SAGBs with timer-controlled aeration. Genomic DNA testing confirmed that the dominant ANAMMOX seed bacteria, received from a treatment plant utilizing the DEMON® sidestream deammonification process, was a Candidatus Brocadia sp. (of the Planctomycetales order). The DNA from these bacteria was also present in the SAGBs at the conclusion of the study providing evidence for attached growth and limited biomass washout.

  1. Analytical solution for tension-saturated and unsaturated flow from wicking porous pipes in subsurface irrigation: The Kornev-Philip legacies revisited

    Science.gov (United States)

    Kacimov, A. R.; Obnosov, Yu. V.

    2017-03-01

    The Russian engineer Kornev in his 1935 book raised perspectives of subsurface "negative pressure" irrigation, which have been overlooked in modern soil science. Kornev's autoirrigation utilizes wicking of a vacuumed water from a porous pipe into a dry adjacent soil. We link Kornev's technology with a slightly modified Philip (1984)'s analytical solutions for unsaturated flow from a 2-D cylindrical pipe in an infinite domain. Two Darcian flows are considered and connected through continuity of pressure along the pipe-soil contact. The first fragment is a thin porous pipe wall in which water seeps at tension saturation; the hydraulic head is a harmonic function varying purely radially across the wall. The Thiem solution in this fragment gives the boundary condition for azimuthally varying suction pressure in the second fragment, ambient soil, making the exterior of the pipe. The constant head, rather than Philip's isobaricity boundary condition, along the external wall slightly modifies Philip's formulae for the Kirchhoff potential and pressure head in the soil fragment. Flow characteristics (magnitudes of the Darcian velocity, total flow rate, and flow net) are explicitly expressed through series of Macdonald's functions. For a given pipe's external diameter, wall thickness, position of the pipe above a free water datum in the supply tank, saturated conductivities of the wall and soil, and soil's sorptive number, a nonlinear equation with respect to the total discharge from the pipe is obtained and solved by a computer algebra routine. Efficiency of irrigation is evaluated by computation of the moisture content within selected zones surrounding the porous pipe.Plain Language SummarySubsurface irrigation by "automatic" gadgets like pitchers or porous pipes is a water saving technology which minimizes evaporative losses and deep percolation. Moisture is emitted by capillary suction of a relatively dry soil and "thirsty" roots just in "right quantities", spontaneously

  2. Using a biological aerated filter to treat mixed water-borne volatile organic compounds and assessing its emissions

    Institute of Scientific and Technical Information of China (English)

    CHENG Wen-Hsi

    2009-01-01

    A biological aerated filter (BAF) was evaluated as a fixed-biofilm processes to remove water-borne volatile organic compounds (VOCs) from a multiple layer ceramic capacitor (MLCC) manufacturing plant in southern Taiwan.The components of VOC were identified to be toluene,1,2,4-trimethylbenzene,1,3,5-trimethylbenzene,bromodichloromethane and isopropanol (IPA).The full-scale BAF was constructed of two separate reactors in series,respectively using 10-cm and 15-cm diameter polypropylene balls as the packing materials and a successful preliminary bench-scale experiment was performed to feasibility.Performance results show that the BAF removed over 90% chemical oxygen demand (COD) from the influent with (1188 ± 605) mg/L of COD.A total organic loading of 2.76 kg biochemical oxygen demand (BOD)/(m~3 packing·d) was determined for the packed bed,in which the flow pattern approached that of a mixed flow.A limited VOC concentration of (0.97 ± 0.29) ppmv (as methane) was emitted from the BAF system.Moreover,the emission rate of VOC was calculated using the proposed formula,based on an air-water mass equilibrium relationship,and compared to the simulated results obtained using the Water 9 model.Both estimation approaches of calculation and model simulation using Water 9 evaluating VOC emissions reveal that 0.1% IPA (0.0031-0.0037 kg/d) was aerated into a gaseous phase,and 30% to 40% (0.006-0.008 kg/d) of the toluene was aerated.

  3. [Biological phosphorus removal in intermittent aerated biological filter].

    Science.gov (United States)

    Zeng, Long-Yun; Yang, Chun-Ping; Guo, Jun-Yuan; Luo, Sheng-Lian

    2012-01-01

    Under intermittent aerated and continuous fed operation where the biofilm system was subjected to alternated anaerobic/aerobic condition, the effect of influent volatile fatty acids (VFAs) concentrations, operation cycle and backwash on the biological phosphorus removal performance of the biofilter was studied. In the experiment, synthetic domestic wastewater was used, and the influent velocity was 5 L x h(-1) with gas versus liquid ratio of 8:1 and hydraulic retention time (HRT) of 1.3 h, resulting in average COD, ammonium and phosphorus load of 4.7, 0.41 and 0.095 g x (L x d) (-1) respectively. Results show that, (1) effective release and uptake of phosphorus was achieved in a operation cycle; (2) when influent VFAs was 100 mg x L(-1) (calculated by COD value) and operation cycle was 6 h the filter performed best in phosphorus removal, the phosphorus loading removal rate can be as much as 0.059 g x (L x d)(-1) at the aerated phase with those of COD and ammonium being 3.8 g x (L x d)(-1) and 0.28 g x (L x d)(-1) respectively, and with average effluent phosphorus, COD and ammonium concentrations being 1.8, 43.6 and 8.7 mg x L(-1), which shows nitrogen loss also happened; (3) the pause of backwash decreased the phosphorus removal performance rapidly with the removal efficiency lower than 40% in two days, but the consequent daily backwash operation gave a short improvement on the phosphorus removal, which disappeared in another two days. Thus, it is shown that biological phosphorus removal achieved with better phosphorus loading removal performance in the biofilter under intermittent aerated and continuous fed operation, and that sufficient and stable influent VFAs concentration, proper operation cycle, and more frequent backwash favored the performance.

  4. Pseudomonads rule degradation of polyaromatic hydrocarbons in aerated sediment

    Directory of Open Access Journals (Sweden)

    Jiri eWald

    2015-11-01

    Full Text Available Given that the degradation of aromatic pollutants in anaerobic environments such as sediment is generally very slow, aeration could be an efficient bioremediation option. Using stable isotope probing (SIP coupled with pyrosequencing analysis of 16S rRNA genes, we identified naphthalene-utilizing populations in aerated polyaromatic hydrocarbon (PAH-polluted sediment. The results showed that naphthalene was metabolized at both 10°C and 20°C following oxygen delivery, with increased degradation at 20°C as compared to 10°C – a temperature more similar to that found in situ. Naphthalene-derived 13C was primarily assimilated by pseudomonads. Additionally, Stenotrophomonas, Acidovorax, Comamonas and other minor taxa were determined to incorporate 13C throughout the measured time course. The majority of SIP-detected bacteria were also isolated in pure cultures, which facilitated more reliable identification of naphthalene-utilizing populations as well as proper differentiation between primary consumers and cross-feeders. The pseudomonads acquiring the majority of carbon were identified as Pseudomonas veronii and P. gessardii. Stenotrophomonads and Acidovorax defluvii, however, were identified as cross-feeders unable to directly utilize naphthalene as a growth substrate. PAH degradation assays with the isolated bacteria revealed that all pseudomonads as well as Comamonas testosteroni degraded acenaphthene, fluorene and phenanthrene in addition to naphthalene. Furthermore, P. veronii and C. testosteroni were capable of transforming anthracene, fluoranthene and pyrene. Screening of isolates for naphthalene dioxygenase genes using a set of in-house designed primers for Gram-negative bacteria revealed the presence of such genes in pseudomonads and Comamonas testosteroni. Overall, our results indicated an apparent dominance of pseudomonads in the sequestration of carbon from naphthalene and potential degradation of other PAHs upon aeration of the

  5. Fouling behavior of microstructured hollow fiber membranes in submerged and aerated filtrations.

    Science.gov (United States)

    Culfaz, P Z; Wessling, M; Lammertink, R G H

    2011-02-01

    The performance of microstructured hollow fiber membranes in submerged and aerated systems was investigated using colloidal silica as a model foulant. The microstructured fibers were compared to round fibers and to twisted microstructured fibers in flux-stepping experiments. The fouling resistances in the structured fibers were found to be higher than those of round fibers. This was attributed to stagnant zones in the grooves of the structured fibers. As the bubble sizes were larger than the size of the grooves of the structured fibers, it is possible that neither the bubbles nor the secondary flow caused by the bubbles can reach the bottom parts of the grooves. Twisting the structured fibers around their axes resulted in decreased fouling resistances. Large, cap-shaped bubbles and slugs were found to be the most effective in fouling removal, while small bubbles of sizes similar to the convolutions in the structured fiber did not cause an improvement in these fibers. Modules in a vertical orientation performed better than horizontal modules when coarse bubbling was used. For small bubbles, the difference between vertical and horizontal modules was not significant. When the structured and twisted fibers were compared to round fibers with respect to the permeate flowrate produced per fiber length instead of the actual flux through the convoluted membrane area, they showed lower fouling resistance than round fibers. This is because the enhancement in surface area is more than the increase in resistance caused by stagnant zones in the grooves of the structured fibers. From a practical point of view, although the microstructure does not promote further turbulence in submerged and aerated systems, it can still be possible to enhance productivity per module with the microstructured fibers due to their high surface area-to-volume ratio.

  6. [Atrazine wastewater treatment in a SPG membrane-aerated genetically engineered microorganism biofilm reactor].

    Science.gov (United States)

    Liu, Chun; Gong, Peng-Fei; Xiao, Tai-Min; Zhang, Ming; Nian, Yong-Jia; Yang, Jing-Liang; Zhang, Jing

    2014-08-01

    Membrane-aerated biofilm reactor (MABR) represent a novel membrane-biological wastewater treatment technology. In addition, bioaugmented treatment using genetically engineered microorganism (GEM) biofilm in MABR is proposed to improve refractory pollutant removal. In the present study, a SPG membrane aerated-biofilm reactor (SPG-MABR) with GEM biofilm formed on the SPG membrane surface was applied to treat atrazine wastewater. The influences of air pressure, biofilm biomass and liquid velocity on the performance of the SPG-MABR were investigated. The variation of GEM biofilm during the SPG-MABR operation was observed. The results indicated that the increased air pressure could promote atrazine and COD removal as well as re-oxygenation by increasing oxygen permeability coefficient. A higher biofilm biomass could also enhance atrazine and COD removal, but simultaneously reduce the re-oxygenation rate because biofilm thickness and oxygen transfer resistance increased. When liquid velocity in the SPG-MABR was decreased under laminar flow condition, atrazine and COD removal was improved due to the facilitated contaminant diffusion from wastewater to biofilm. The atrazine removal efficiency reached to 98.6% in the SPG-MABR after 5d treatment at air pressure of 300 kPa, biofilm biomass of 25 g x m(-2) and liquid velocity of 0.05 m x s(-1). The microbial polymorphism of GEM biofilm was observed during the SPG-MABR operation. The surface of GEM biofilm was gradually covered by other microbial cells and the distribution of GEM cells reduced, but inside the GEM biofilm, the GEM cells were still dominant.

  7. Modelling and test of aeration tank settling (ATS)

    DEFF Research Database (Denmark)

    Nielsen, M. K.; Bechmann, H.; Henze, Mogens

    2000-01-01

    that a qualitatively correct model can be established. The simplicity of the model allows for on-line identification of the necessary parameters, so that no maintenance is needed to use of the on-line model for control. The practical implementation on three plants indicates that implementation of STAR with ATS control......The use of aeration tank settling during high hydraulic loads on large wastewater treatment plants has previously been demonstrated as a reliable technique and proven valuable. The paper proposes a simplified deterministic model to predict the efficiency of the method. It is shown...

  8. Pulverizing aeration as a method of lakes restoration

    Science.gov (United States)

    Kaczorowska, E.; Podsiadłowski, S.

    2012-04-01

    The principal threat to lakes of the temperate zone is posed by factors accelerating their eutrophication and causing marked deoxygenation of the deeper layers of water, mainly the hypo- and metalimnion. Among their effects are frequent phytoplankton blooms, including those of blue-green algae, and general deterioration of water quality also affecting the abundance and health status of fish. The chief concern is a disturbed proportion between the amount of complex chemical compounds, especially organic, and the oxygen content of lake waters. Natural processes of water oxygenation are not too intensive, because they are practically limited to the epilimnion layer, connected as they are with the activity of aquatic plants of the littoral and sublittoral zone (which tends to disappear in contaminated lakes) and wind energy (the effect of waving). In summer conditions, with a relatively great chemical activity of bottom deposits, the intensity of those processes is usually inadequate. Hence, in 1995 a research was launched in the Institute of Agricultural Engineering of the Agricultural University in Poznań on an integrated lake restoration technology whose core was a self-powered aerator capable of oxygenating also the bottom layers of water (the hypolimnion) of deep lakes. The aerator uses energy obtained from a Savonius rotor mainly to diffuse gases: to release hydrogen sulphide, which usually saturates the hypolimnion water completely, and then to saturate this water with oxygen. Even early studies showed the constructed device to be highly efficient in improving oxygen conditions in the bottom zone. They also made it clear that it should be equipped with an autonomous system designed to inactivate phosphorus, one of the principal factors determining the rate of lake degradation. In 2003 the first wind-driven pulverising aerator equipped with such a system was installed in Town Lake in Chodzież. The aim of this work is to present the principles of operation of a

  9. Galvanic corrosion of nitinol under deaerated and aerated conditions.

    Science.gov (United States)

    Pound, Bruce G

    2016-10-01

    Various studies have examined the corrosion rate of nitinol generally under deaerated conditions. Likewise, galvanic corrosion studies have typically involved deaerated solutions. This work addressed the effect of galvanic coupling on the corrosion current of electropolished nitinol in phosphate buffered saline and 0.9% sodium chloride under dearated and aerated conditions for times up to 24 h. Tests were performed on nitinol alone and coupled with MP35N in both the mechanically polished and passivated conditions. Aeration and galvanic coupling were found to have relatively little effect, indicating that the corrosion current is controlled by the anodic reaction. The current can be attributed entirely to Ni(2+) dissolution, which appears to be governed by solid-state mass transport of Ni(2+) through the passive oxide film. Because corrosion of EP nitinol is controlled by the anodic reaction, contact between EP nitinol and MP35N or other biomedical Co-Cr alloys is unlikely to result in significant galvanic effects in vivo. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 104B: 1322-1327, 2016. © 2015 Wiley Periodicals, Inc.

  10. The Potential of Extended Aeration System for Sago Effluent Treatment

    Directory of Open Access Journals (Sweden)

    Wahi A. Rashid

    2010-01-01

    Full Text Available Problem statement: Sago effluent contains large amount of organic material which has a potential to cause water pollution. In order to reduce this problem, an experiment was conducted to remove organic material from sago effluent using lab scale of Extended Aeration (EA system. Approach: The EA system consisted of the combination of physical and biological treatment unit. For Physical Treatment Unit (PTU, the sago effluent was filtered using 710 µm mesh size filter. For Biological Treatment Unit (BTU, the effluent were mixed and aerated with activated sago sludge for 48 h. The treatment efficiency with respect to Biological Oxygen Demand (BOD, Chemical Oxygen Demand (COD and Total Suspended Solid (TSS removal were evaluated and compared with regulatory requirement by Department of Environment, Malaysia. Results: The result showed, the EA system could reduce BOD, COD and TSS up to 84, 87.8 and 73% respectively, however it did not comply with the regulatory requirement. Conclusion: This study suggested the EA system have potential to be apply on sago effluent, however it should be integrated with additional treatment unit to achieve the effluent quality standard.

  11. The use of bottle caps as submerged aerated filter medium.

    Science.gov (United States)

    Damasceno de Oliveira, Laurence; Motlagh, Amir Mohaghegh; Goel, Ramesh; de Souza Missagia, Beatriz; Alves de Abreu Filho, Benício; Lautenschlager, Sandro Rogério

    2014-01-01

    In this study, a submerged aerated filter (SAF) using bottle caps as a support medium was evaluated. The system was fed with effluent from an upflow anaerobic sludge blanket system at ETE 2-South wastewater treatment plant, under different volumetric organic load rates (VOLRs). The population of a particular nitrifying microbial community was assessed by fluorescent in situ hybridization with specific oligonucleotide probes. The system showed an average removal of chemical oxygen demand (COD) equal to 76% for VOLRs between 2.6 and 13.6 kg COD m(-3)_media.day(-1). The process of nitrification in conjunction with the removal of organic matter was observed from applying VOLRs lower than 5.5 kg COD m(-3)_media.day(-1) resulting in 78% conversion of NH4(+)-N. As the applied organic load was reduced, an increase in the nitrifying bacteria population was observed compared with total 4'-6-diamidino-2-phenylindole (DAPI) stained cells. Generally, SAF using bottle caps as a biological aerated filter medium treating wastewater from an anaerobic system showed promising removal of chemical oxygen demand (COD) and conversion of NH4(+)-N.

  12. 40 CFR 265.278 - Unsaturated zone (zone of aeration) monitoring.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 25 2010-07-01 2010-07-01 false Unsaturated zone (zone of aeration) monitoring. 265.278 Section 265.278 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED..., STORAGE, AND DISPOSAL FACILITIES Land Treatment § 265.278 Unsaturated zone (zone of aeration)...

  13. Sequentially aerated membrane biofilm reactors for autotrophic nitrogen removal: microbial community composition and dynamics

    DEFF Research Database (Denmark)

    Pellicer i Nàcher, Carles; Franck, Stephanie; Gülay, Arda;

    2014-01-01

    Membrane-aerated biofilm reactors performing autotrophic nitrogen removal can be successfully applied to treat concentrated nitrogen streams. However, their process performance is seriously hampered by the growth of nitrite oxidizing bacteria (NOB). In this work we document how sequential aeration...

  14. Surfactant effects on alpha factors in full-scale wastewater aeration systems.

    Science.gov (United States)

    Rosso, D; Larson, L E; Stenstrom, M K

    2006-01-01

    Aeration is an essential process in the majority of wastewater treatment processes, and accounts for the largest fraction of plant energy costs. Aeration systems can achieve wastewater oxygenation by shearing the surface (surface aerators) or releasing bubbles at the bottom of the tank (coarse- or fine-bubble aerators). Surfactants accumulate on gas-liquid interfaces and reduce mass transfer rates. This reduction in general is larger for fine-bubble aerators. This study was conducted to evaluate mass transfer effects on the characterization and specification of aeration systems in clean and process water conditions. Tests at different interfacial turbulence regimes were analysed, showing higher gas transfer depression for lower turbulence regimes. Higher turbulence regimes can offset contamination effects, at the expense of operating efficiency. This phenomenon is characteristic of surface aerators and coarse bubble diffusers and is here discussed. The results explain the variability of alpha factors measured at small scale, due to uncontrolled energy density. Results are also reported in dimensionless empirical correlations that describe mass transfer as a function of physiochemical and geometrical characteristics of the aeration process.

  15. Passively Aerated Composting of Straw-Rich Pig Manure : Effect of Compost Bed Porosity

    NARCIS (Netherlands)

    Veeken, A.H.M.; Wilde, de V.; Hamelers, H.V.M.

    2002-01-01

    Straw-rich manure from organic pig farming systems can be composted in passively aerated systems as the high application of straw results in a compost bed with good structure and porosity. The passively aerated composting process was simulated in one-dimensional reactors of 2 m3 for straw-rich

  16. Similarity and analytical solutions of free convective flow of dilatant nanofluid in a Darcian porous medium with multiple convective boundary conditions

    Directory of Open Access Journals (Sweden)

    M.J. Uddin

    2016-03-01

    Full Text Available This paper deals with an analytical solution of free convective flow of dilatant nanofluid past a vertical cone/plate. A two-phase mixture model is used for nanofluid in which the Brownian motion and thermophoretic diffusivities are the important slip mechanisms between solid and liquid phases. The governing transport equations along with physically realistic thermal and mass convective boundary conditions are reduced to similarity equations using relevant similarity transformations before being solved by homotopy analysis method. The effects of the governing parameters (Brownian motion, thermophoresis, convection–conduction, convection–diffusion, Lewis number, buoyancy ratio, and power-law on the dimensionless velocity, temperature and nanoparticle volume fraction, friction and heat transfer rates are plotted and discussed. It is found that friction factor decreases with the increase in Le and Nr for both vertical plate and cone. The local Nusselt number decreases with the increase in the thermophoresis and Brownian motion parameters for both the plate and cone. The local Sherwood number increases with the Brownian motion parameter and decreases for thermophoresis parameter. The results have been compared with the published ones and an excellent agreement has been noticed.

  17. Numerical and analytical solutions of Neutrino-Dominated Accretion Flows with a Non-Zero Torque Boundary Condition and its applications in Gamma-ray Bursts

    CERN Document Server

    Xie, Wei; Wang, Ding-Xiong

    2016-01-01

    A stellar mass black hole (BH) surrounded by a neutrino-dominated accretion flow (NDAF) has been discussed in a number of works as the central engine of gamma-ray bursts (GRBs). It is widely believed that NDAF cannot liberate enough energy for bright GRBs. However, these works have been based on the assumption of "no torque" boundary condition, which is invalid when the disk is magnetized. In this paper, we present both numerical and analytical solutions for NDAFs with non-zero boundary stresses, and reexamine their properties. We find that NDAF with such boundary torque can be powerful enough to account for those bright short GRBs, energetic long GRBs and ultra-long GRBs. The disk becomes viscously unstable, which makes it possible to interpret the variability of GRB prompt emission and the steep decay phase in the early X-ray afterglow. Finally, we study the gravitational waves radiated from a processing BH-NDAF. We find that the effects of the boundary torque on the strength of the gravitational waves can ...

  18. An improved analytical method for the determination of urea nitrogen isotopomers in biological samples utilizing continuous flow isotope ratio mass spectrometry.

    Science.gov (United States)

    Marini, Juan C; Attene-Ramos, Matias Sebastian

    2006-01-01

    Over the past few years numerous dual inlet isotope ratio mass spectrometry (IRMS) applications have been adapted to continuous flow systems which allow the automation of sample admission and a higher throughput. The isotopomer analysis of urea nitrogen by IRMS requires the offline conversion of urea into nitrogen gas before analysis. The oxidation of urea with LiOBr results in the monomolecular degradation of urea, which preserves the identity of the parent urea molecule, and has to be conducted under vacuum to prevent contamination with atmospheric nitrogen. We have developed an offline system of urea degradation utilizing disposable Exetainers, in which atmospheric nitrogen is displaced by helium. Recovery of urea nitrogen was linear within the range of the standards tested (0 to 420 microg nitrogen) and standard curves for 15N15N-urea standards showed high coefficients of determination (R2 > 0.9998). A small portion of urea degrades in a non-monomolecular fashion and has been shown to depend on the concentration of urea in the sample. Long-term storage of prepared samples showed a decline in 15N15N enrichment, suggesting air contamination. However, samples were stable for 24 h, which allows for the analysis of large sample batches. Interest in urea metabolism, particularly in ruminant species, has increased recently due to the environmental implications of urea and nitrogen excretion by farm animals. This novel analytical method will allow for accurate measurements and the rapid throughput needed in order to support these field studies.

  19. Heat transfer and fluid flow of blood with nanoparticles through porous vessels in a magnetic field: A quasi-one dimensional analytical approach.

    Science.gov (United States)

    Rahbari, A; Fakour, M; Hamzehnezhad, A; Vakilabadi, M Akbari; Ganji, D D

    2017-01-01

    In the present study, the analytical study on blood flow containing nanoparticles through porous blood vessels is done in presence of magnetic field using Homotopy Perturbation Method (HPM). Blood is considered as the third grade non- Newtonian fluid containing nanoparticles. Viscosity of nanofluid is determined by Constant, Reynolds' and Vogel's models. Some efforts have been made to show the reliability and performance of the present method compared with the numerical method, Runge-Kutta fourth-order. The results reveal that the HPM can achieve suitable results in predicting the solution of these problems. Moreover, the influence of some physical parameters such as pressure gradient, Brownian motion parameter, thermophoresis parameter, magnetic filed intensity and Grashof number on temperature, velocity and nanoparticles concentration profiles is declared in this research. The results reveal that the increase in the pressure gradient and Thermophoresis parameter as well as decrease in the Brownian motion parameter cause the rise in the velocity profile. Furthermore, either increase in Thermophoresis or decrease in Brownian motion parameters results in enhancement in nanoparticle concentration. The highest value of velocity is observed when the Vogel's Model is used for viscosity. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Nitrous oxide emissions from an intermittent aeration activated sludge system of an urban wastewater treatment plant

    Directory of Open Access Journals (Sweden)

    William Z. de Mello

    2013-01-01

    Full Text Available This study investigated the emission of N2O during the sequential aerated (60-min and non-aerated (30-min stages of an intermittent aeration cycle in an activated sludge wastewater treatment plant (WWTP. N2O emission occurred during both stages; however, emission was much higher during aeration. Air stripping is the major factor controlling transfer of N2O from the sewage to the atmosphere. The N2O emissions exclusively from the aeration tank represented 0.10% of the influent total nitrogen load and the per capita emission factor was almost 3 times higher than that suggested by the IPCC for inventories of N2O emission from WWTPs.

  1. Effects of intermittent aeration on pollutants removal in subsurface wastewater infiltration system.

    Science.gov (United States)

    Pan, Jing; Fei, Hexin; Song, Siyu; Yuan, Fang; Yu, Long

    2015-09-01

    In this study, the pollutant removal performances in two pilot-scale subsurface wastewater infiltration systems (SWISs) with and without intermittent aeration were investigated. Matrix oxidation reduction potential (ORP) results showed that intermittent aeration well developed aerobic conditions in upper matrix and anoxic or anaerobic conditions in the subsequent sections, which resulted in high NH4(+)-N and TN removal. Moreover, intermittent aeration increased removal rates of COD and TP. Microbial populations and enzyme activities analysis proved that intermittent aeration not only obviously boosted the growth and reproduction of bacteria, fungus, actinomyces, nitrifying bacteria and denitrifying bacteria, but also successfully increased nitrate reductase (NR) and nitrite reductase (NIR) in the depth of 80 and 110 cm. The results suggest that the intermittent aeration could be a widespread research and application strategy for achieving the high removal performance in SWISs.

  2. [Optimization and comparison of nitrogen and phosphorus removal by different aeration modes in oxidation ditch].

    Science.gov (United States)

    Guo, Chang-Zi; Peng, Dang-Cong; Cheng, Xue-Mei; Wang, Dan

    2012-03-01

    The oxidation ditch operation mode was simulated by sequencing batch reactor (SBR) system with alternate stirring and aeration. The nitrogen and phosphorus removal efficiencies were investigated in two different aeration modes: point aeration and step aeration. Experimental results show that oxygen is dissolved more efficiently in point aeration mode with a longer aerobic region in the same air supply capacity, but dissolved oxygen (DO) utilization efficiency for nitrogen and phosphorus removal is high in step aeration mode. Nitrification abilities of the two modes are equal with ammonia-nitrogen (NH4(+) -N) removal efficiency of 96.68% and 97.03%, respectively. Nitrifier activities are 4.65 and 4.66 mg x (g x h)(-1) respectively. When the ratio of anoxic zones and the aerobic zones were 1, the total nitrogen (TN) removal efficiency of point aeration mode in 2, 4 or 7 partitions was respectively 60.14%, 47.93% and 33.7%. The total phosphorus (TP) removal efficiency was respectively 28.96%, 23.75% and 24.31%. The less the partitions, the higher the nitrogen and phosphorus removal efficiencies, but it is in more favor of TN removal. As for step aeration mode with only one partitioning zone, the TN and TP removal efficiencies are respectively 64.21% and 49.09%, which is better than in point aeration mode, but more conducive to the improvement of TP removal efficiency. Under the condition of sufficient nitrification in step aeration mode, the nitrogen and phosphorus removal is better with the increase of anoxic zone. The removal efficiencies of TN and TP respectively rose to 73.94% and 54.18% when the ratio of anoxic zones and the aerobic zones was increased from 1 : 1 to 1. 8 : 1. As the proportion of anoxic zones was enlarged further, nitrification and operation stability were weakened so as to affect the nitrogen and phosphorus removal efficiencies.

  3. Aeration-Controlled Formation of Acid in Heterolactic Fermentations

    DEFF Research Database (Denmark)

    Adler-Nissen, Jens

    1994-01-01

    Controlled aeration of Leuconostoc mesenteroides was studied as a possible mechanism for control of the formation of acetic acid, a metabolite of major influence on the taste of lactic fermented foods. Fermentations were carried out in small scale in a medium in which growth was limited...... by the buffer capacity only. Ethanol and acetic acid formed during the fermentation were analyzed by rapid head space gas chromatography, and the ratio of the molar concentrations of these two volatiles quantitatively predicted the balance between the formation of acetic acid and lactic acid. The oxygen...... fermentation processes should be analyzed as fed-batch fermentations with oxygen as the limiting substrate. Addition of fructose in limited amounts leads to the formation of one half mole of acetic acid for each mole fructose, thus offering an alternative mechanism for controlling acetic acid formation....

  4. Cracking in autoclaved aerated concrete: Experimental investigation and XFEM modeling

    Energy Technology Data Exchange (ETDEWEB)

    Ferretti, D., E-mail: daniele.ferretti@unipr.it [Department of Civil, Environmental, Land Management Engineering and Architecture, University of Parma, P.co Area delle Scienze 181/A, 43124 Parma (Italy); Michelini, E. [Department of Civil, Environmental, Land Management Engineering and Architecture, University of Parma, P.co Area delle Scienze 181/A, 43124 Parma (Italy); Rosati, G. [Department of Civil and Environmental Engineering, Politecnico di Milano, Piazza L. Da Vinci 32, 20133 Milano (Italy)

    2015-01-15

    The paper aims to investigate and model cracking development in beams and deep-beams made of autoclaved aerated concrete (AAC). Fracture mechanics of AAC has been first studied by performing three-point bending tests on beams, similar to those commonly used for ordinary concrete elements. In some of these tests, crack growth has been also monitored by using ESPI laser technique. In this way, it has been possible to calibrate the main parameters of a proper cohesive law by means of extended finite element inverse analysis. Subsequently, cracking tests have been also performed on deep-beams, whose behavior is more representative of full scale walls. To validate the proposed cohesive law, deep-beam experimental behavior has been finally simulated through XFEM.

  5. Thermal conductivity of newspaper sandwiched aerated lightweight concrete panel

    Energy Technology Data Exchange (ETDEWEB)

    Ng, Soon-Ching; Low, Kaw-Sai [Faculty of Engineering and Science, Universiti Tunku Abdul Rahman, Jalan Genting Kelang, Setapak, 53300 Kuala Lumpur, Wilayah Persekutuan (Malaysia)

    2010-12-15

    Investigation on the thermal conductivity of newspaper sandwiched aerated lightweight concrete (ALC) panels is the main purpose of this study. Various densities of ALC panels ranging from 1700, 1400 and 1100 kg/m{sup 3} with three different aerial intensities of newspaper sandwiched were produced. Investigation was limited to the effect of aerial intensity of newspaper sandwiched and the effect of density of ALC on thermal conductivity. It is found that the thermal conductivity of newspaper sandwiched ALC panels reduced remarkably compared to control ALC panels. The reduction was recorded at 18.0%, 21.8% and 20.7% correspond to densities of 1700, 1400 and 1100 kg/m{sup 3} with just a mere 0.05 g/cm{sup 2} aerial intensity of newspaper sandwiched. Newspaper sandwiched has a significant impact on the performance of thermal conductivity of ALC panels based on regression analysis. (author)

  6. Nitrogen and phosphorus removal under intermittent aeration conditions

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    A practice wastewater treatment plant was operated usingintermittent aeration activated sludge process to enhancebiological nitrogen and phosphorus removal. When the influentconcentrations of CODCr, BOD5, TN, TP, NH3-N, TKN, and SS varied ina range of 207.5-1640 mg/L, 61.8-637 mg/L, 28.5-75.6 mg/L, 4.38-20.2 mg/L, 13.6-31.9 mg/L, 28.5-75.6 mg/L, and 111-1208 mg/L, theeffluent means were less than 50 mg/L, 20 mg/L, 5 mg/L, 1.0 mg/L,5 mg/L, 10 mg/L, and 20 mg/L, respectively. Based on a long time ofoperating results, this process is very suitable for nutrientbiological removal for treating the municipal wastewater thosewater characteristics are similar as that of the Songjiang Municipal Waste water Treatment plant(SJMWTP).

  7. DOMESTIC WASTEWATER PURIFICATION IN UPFLOW BIOFILM SYSTEM WITH DIFFUSED AERATION

    Directory of Open Access Journals (Sweden)

    A.Mesdaghinia

    1984-08-01

    Full Text Available The objective of this research was to conduct a bench scale study of fixed activated sludge treating domestic sewage. Two different units employing diffused aeration with plastic and aluminum media were studied in four separate phases. Data indicated that the system could produce a high quality effluent without any requirements for sludge recycling through the system. Suspended solids concentrations of 3-6 mg/1, BOD5 concentrations of 4-12 mg/1 and COD concentrations of 35-45 mg/1 were found in the effluent with wastewater retentions ranging from 3-15 hours, whereas an indication of nitrification was observed in higher detention periods. As far as the type of media was concerned, the plastic and aluminum media did not differ significantly once the microbes had grown on the media.

  8. Effects of loading rate and aeration on nitrogen removal and N2O emissions in intermittently aerated sequencing batch reactors treating slaughterhouse wastewater at 11 °C.

    Science.gov (United States)

    Pan, Min; Hu, Zhenhu; Liu, Rui; Zhan, Xinmin

    2015-04-01

    This study aimed to find optimal operation conditions for nitrogen removal from high strength slaughterhouse wastewater at 11 °C using the intermittently aerated sequencing batch reactors (IASBRs) so as to provide an engineering control strategy for the IASBR technology. Two operational parameters were examined: (1) loading rates and (2) aeration rates. Both the two parameters affected variation of DO concentrations in the IASBR operation cycles. It was found that to achieve efficient nitrogen removal via partial nitrification-denitrification (PND), "DO elbow" point must appear at the end of the last aeration period. There was a correlation between the ammonium oxidizing bacteria (AOB)/nitrite oxidizing bacteria (NOB) ratio and the average DO concentrations in the last aeration periods; when the average DO concentrations in the last aeration periods were lower than 4.86 mg/L, AOB became the dominant nitrifier population, which benefited nitrogen removal via PND. Both the nitrogen loading rate and the aeration rate influenced the population sizes of AOB and NOB. To accomplish efficient nitrogen removal via PND, the optimum aeration rate (A, L air/min) applied can be predicted according to the average organic loading rates based on mathematical equations developed in this study. The research shows that the amount of N2O generation in the aeration period was reduced with increasing the aeration rate; however, the highest N2O generation in the non-aeration period was observed at the optimum aeration rates.

  9. [Effects of substrate-aeration cultivation pattern on tomato growth].

    Science.gov (United States)

    Zhao, Xu; Li, Tian-Lai; Sun, Zhou-Ping

    2010-01-01

    Aeroponics can increase the fruit yield of tomato plant, but its cost is very high. In this paper, tomato seedlings were planted with three cultures, i. e., whole perlite culture (CK), perlite-aeration culture (T1), and aeroponics (T2), and a comparative study was made on the seedlings growth. Compared with CK, T1 improved the gas environment in root zone significantly, with the CO2 and O2 concentrations in root zone being 0.2 and 1.17 times higher, and increased the plant height and stem diameter after 60 days of transplanting by 5.1% and 8.4%, respectively. The plant net photosynthetic rate of T1 was significantly higher than that of CK, with the maximum value after transplanting 45 days increased by 13%. T1 also increased the root activity and ion absorbing ability significantly, with the root activity after transplanting 45 days being 1.23 times of CK, and the root K, Ca, and Mg contents after transplanting 60 days increased by 31%, 37%, and 27%, respectively. The fruit yield of T1 was 1.16 times of CK. No significant differences in these indices were observed between T1 and T2, and less difference in the fruit soluble sugar and organic acid contents as well as the sugar-acid ratio was found among CK, T1, and T2. It was suggested that perlite-aeration cultivation pattern was an easy and feasible way to markedly improve the fruit yield of tomato plant.

  10. Seasonal effects of pre-aeration on microbial processes for nitrogen removal in constructed wetlands.

    Science.gov (United States)

    Wang, Ling; Li, Tian

    2017-02-01

    Seasonal effects of pre-aeration on microbial nitrogen performance in constructed wetlands (CWs) involved with anaerobic ammonium oxidation (anammox) process were investigated in this study. Slow natural re-aeration rate was the inhibiting factor for total nitrogen removal in CW without pre-aeration, and partial nitrification was the main way for nitrite generation. Besides partial nitrification, pre-aeration provided nitrite generation in CWs with an alternative way: nitrate reduction. Advantage of pre-aeration of influent was much different under various temperature ranges. Mean temperature of 15 °C seemed to be the turning point. With a mean temperature of or higher than 15 °C, nitrate in the influent effectively improved nitrogen removal in CWs. With a mean temperature lower than 15 °C, the nitrate reduction process in CWs was greatly inhibited. The benefit of pre-aeration was weak under this temperature range. Seasonal aeration pattern for the pre-treatment of HSSF CWs might be a more energy-saving alternative in in-suit domestic sewage treatment.

  11. Ammonia-based feedforward and feedback aeration control in activated sludge processes.

    Science.gov (United States)

    Rieger, Leiv; Jones, Richard M; Dold, Peter L; Bott, Charles B

    2014-01-01

    Aeration control at wastewater treatment plants based on ammonia as the controlled variable is applied for one of two reasons: (1) to reduce aeration costs, or (2) to reduce peaks in effluent ammonia. Aeration limitation has proven to result in significant energy savings, may reduce external carbon addition, and can improve denitrification and biological phosphorus (bio-P) performance. Ammonia control for limiting aeration has been based mainly on feedback control to constrain complete nitrification by maintaining approximately one to two milligrams of nitrogen per liter of ammonia in the effluent. Increased attention has been given to feedforward ammonia control, where aeration control is based on monitoring influent ammonia load. Typically, the intent is to anticipate the impact of sudden load changes, and thereby reduce effluent ammonia peaks. This paper evaluates the fundamentals of ammonia control with a primary focus on feedforward control concepts. A case study discussion is presented that reviews different ammonia-based control approaches. In most instances, feedback control meets the objectives for both aeration limitation and containment of effluent ammonia peaks. Feedforward control, applied specifically for switching aeration on or off in swing zones, can be beneficial when the plant encounters particularly unusual influent disturbances.

  12. Influence of aeration intensity on mature aerobic granules in sequencing batch reactor.

    Science.gov (United States)

    Gao, Da-Wen; Liu, Lin; Liang, Hong

    2013-05-01

    Aeration intensity is well known as an important factor in the formation of aerobic granules. In this research, two identical lab-scale sequencing batch reactors with aeration intensity of 0.8 (R1) and 0.2 m(3)/h (R2) were operated to investigate the characteristics and kinetics of matured aerobic granules. Results showed that both aeration intensity conditions induced granulation, but they showed different effects on the characteristics of aerobic granules. Compared with the low aeration intensity (R2), the aerobic granules under the higher aeration intensity (R1) had better physical characteristics and settling ability. However, the observed biomass yield (Y obs) in R1 [0.673 kg mixed liquor volatile suspended solids (MLVSS)/kg chemical oxygen demand (COD)] was lower than R2 (0.749 kg MLVSS/kg COD). In addition, the maximum specific COD removal rates (q max) and apparent half rate constant (K) of mature aerobic granular sludge under the two aeration intensities were at a similar level. Therefore, the matured aerobic granule system does not require to be operated in a higher aeration intensity, which will reduce the energy consumption.

  13. Development of a model for activated sludge aeration systems: linking air supply, distribution, and demand.

    Science.gov (United States)

    Schraa, Oliver; Rieger, Leiv; Alex, Jens

    2017-02-01

    During the design of a water resource recovery facility, it is becoming industry practice to use simulation software to assist with process design. Aeration is one of the key components of the activated sludge process, and is one of the most important aspects of modelling wastewater treatment systems. However, aeration systems are typically not modelled in detail in most wastewater treatment process modelling studies. A comprehensive dynamic aeration system model has been developed that captures both air supply and demand. The model includes sub-models for blowers, pipes, fittings, and valves. An extended diffuser model predicts both oxygen transfer efficiency within an aeration basin and pressure drop across the diffusers. The aeration system model allows engineers to analyse aeration systems as a whole to determine biological air requirements, blower performance, air distribution, control valve impacts, controller design and tuning, and energy costs. This enables engineers to trouble-shoot the entire aeration system including process, equipment and controls. It also allows much more realistic design of these highly complex systems.

  14. Simultaneous nitrogen and organics removal using membrane aeration and effluent ultrafiltration in an anaerobic fluidized membrane bioreactor

    KAUST Repository

    Ye, Yaoli

    2017-08-03

    Dissolved methane and a lack of nutrient removal are two concerns for treatment of wastewater using anaerobic fluidized bed membrane bioreactors (AFMBRs). Membrane aerators were integrated into an AFMBR to form an Aeration membrane fluidized bed membrane bioreactor (AeMFMBR) capable of simultaneous removal of organic matter and ammonia without production of dissolved methane. Good effluent quality was obtained with no detectable suspended solids, 93±5% of chemical oxygen demand (COD) removal to 14±11 mg/L, and 74±8% of total ammonia (TA) removal to 12±3 mg-N/L for domestic wastewater (COD of 193±23 mg/L and TA of 49±5 mg-N/L) treatment. Nitrate and nitrite concentrations were always low (< 1 mg-N/L) during continuous flow treatment. Membrane fouling was well controlled by fluidization of the granular activated carbon (GAC) particles (transmembrane pressures maintained <3 kPa). Analysis of the microbial communities suggested that nitrogen removal was due to nitrification and denitrification based on the presence of microorganisms associated with these processes.

  15. Analytic materials.

    Science.gov (United States)

    Milton, Graeme W

    2016-11-01

    The theory of inhomogeneous analytic materials is developed. These are materials where the coefficients entering the equations involve analytic functions. Three types of analytic materials are identified. The first two types involve an integer p. If p takes its maximum value, then we have a complete analytic material. Otherwise, it is incomplete analytic material of rank p. For two-dimensional materials, further progress can be made in the identification of analytic materials by using the well-known fact that a 90(°) rotation applied to a divergence-free field in a simply connected domain yields a curl-free field, and this can then be expressed as the gradient of a potential. Other exact results for the fields in inhomogeneous media are reviewed. Also reviewed is the subject of metamaterials, as these materials provide a way of realizing desirable coefficients in the equations.

  16. Analytic Materials

    CERN Document Server

    Milton, Graeme W

    2016-01-01

    The theory of inhomogeneous analytic materials is developed. These are materials where the coefficients entering the equations involve analytic functions. Three types of analytic materials are identified. The first two types involve an integer $p$. If $p$ takes its maximum value then we have a complete analytic material. Otherwise it is incomplete analytic material of rank $p$. For two-dimensional materials further progress can be made in the identification of analytic materials by using the well-known fact that a $90^\\circ$ rotation applied to a divergence free field in a simply connected domain yields a curl-free field, and this can then be expressed as the gradient of a potential. Other exact results for the fields in inhomogeneous media are reviewed. Also reviewed is the subject of metamaterials, as these materials provide a way of realizing desirable coefficients in the equations.

  17. Aeration of the teuftal landfill: Field scale concept and lab scale simulation.

    Science.gov (United States)

    Ritzkowski, Marco; Walker, Beat; Kuchta, Kerstin; Raga, Roberto; Stegmann, Rainer

    2016-09-01

    Long lasting post-closure care (PCC) is often the major financial burden for operators of municipal solid waste (MSW) landfills. Beside costs for the installation and maintenance of technical equipment and barriers, in particular long term treatment of leachate and landfill gas has to be paid from capital surplus. Estimations based on laboratory experiments project time periods of many decades until leachate quality allows for direct discharge (i.e. no need for further purification). Projections based on leachate samples derived from the last 37years for 35 German landfills confirm these assumption. Moreover, the data illustrate that in particular ammonium nitrogen concentrations are likely to fall below limit values only after a period of 300years. In order to avoid long lasting PCC the operator of Teuftal landfill, located in the Swiss canton Bern, decided to biologically stabilize the landfill by means of a combined in situ aeration and moisturization approach. In December 2014 the aeration started at a landfill section containing approximately 30% of the total landfill volume. From summer 2016 onwards the remaining part of the landfill will be aerated. Landfill aeration through horizontal gas and leachate drains is carried out for the first time in field scale in Europe. The technical concept is described in the paper. Parallel to field scale aeration, investigations for the carbon and nitrogen turnover are carried out by means of both simulated aerated landfills and simulated anaerobic landfills. The results presented in this paper demonstrate that aeration is capable to enhance, both carbon mobilization and discharge via the gas phase. This effect comes along with a significant increase in bio-stabilization of the waste organic fraction, which positively affects the landfill emission behavior in the long run. In terms of leachate pollution reduction it could be demonstrated that the organic load decrease fast and widely independent of the adjusted aeration

  18. Design of high efficiency and energy saving aeration device for aquaculture

    Science.gov (United States)

    Liu, Sibo

    2017-03-01

    Energy efficient aeration device for aquaculture, in line with "by more than a generation, dynamic aeration" train of thought for technical design and improvement. Removable aeration terminal as the core, multi-level water to improve the method, the mobile fading pore aeration, intelligent mobile and open and close as the main function, aimed at solving the existing pond aeration efficiency, low energy consumption is high, the function of a single problem. From energy saving, efficiency, biological bacteria on the three directions, the aquaculture industry of energy conservation and emissions reduction. Device of the main advantages are: 1, original mobile fading aerator on the one hand, to expand the scope of work, playing a micro porous aeration of dissolved oxygen with high efficiency and to achieve "by more than a generation", on the other hand, through the sports equipment, stir the mixture of water, the water surface of photosynthesis of plants rich in dissolved oxygen input parts of the tank, compared to the stillness of the aerator can be more fully dissolved oxygen.2, through the opening of the pressure sensor indirect control device, can make the equipment timely and stop operation, convenient in use at the same time avoid the waste of energy.3, the biofilm suspension in aeration terminal, can be accomplished by nitration of microbial multi-level water improvement, still can make biofilm increase rate of netting in the movement process, the biological and mechanical aerobic promote each other, improve the efficiency of both. In addition, the device has small power consumption, low cost of characteristics. And have a certain degree of technical barriers, have their own intellectual property rights, and high degree of product market demand, easily accepted by customers, has a very high popularization value.

  19. 3D-modelling of the thermal circumstances of a lake under artificial aeration

    Science.gov (United States)

    Tian, Xiaoqing; Pan, Huachen; Köngäs, Petrina; Horppila, Jukka

    2017-06-01

    A 3D-model was developed to study the effects of hypolimnetic aeration on the temperature profile of a thermally stratified Lake Vesijärvi (southern Finland). Aeration was conducted by pumping epilimnetic water through the thermocline to the hypolimnion without breaking the thermal stratification. The model used time transient equation based on Navier-Stokes equation. The model was fitted to the vertical temperature distribution and environmental parameters (wind, air temperature, and solar radiation) before the onset of aeration, and the model was used to predict the vertical temperature distribution 3 and 15 days after the onset of aeration (1 August and 22 August). The difference between the modelled and observed temperature was on average 0.6 °C. The average percentage model error was 4.0% on 1 August and 3.7% on 22 August. In the epilimnion, model accuracy depended on the difference between the observed temperature and boundary conditions. In the hypolimnion, the model residual decreased with increasing depth. On 1 August, the model predicted a homogenous temperature profile in the hypolimnion, while the observed temperature decreased moderately from the thermocline to the bottom. This was because the effect of sediment was not included in the model. On 22 August, the modelled and observed temperatures near the bottom were identical demonstrating that the heat transfer by the aerator masked the effect of sediment and that exclusion of sediment heat from the model does not cause considerable error unless very short-term effects of aeration are studied. In all, the model successfully described the effects of the aerator on the lake's temperature profile. The results confirmed the validity of the applied computational fluid dynamic in artificial aeration; based on the simulated results, the effect of aeration can be predicted.

  20. Analytic trigonometry

    CERN Document Server

    Bruce, William J; Maxwell, E A; Sneddon, I N

    1963-01-01

    Analytic Trigonometry details the fundamental concepts and underlying principle of analytic geometry. The title aims to address the shortcomings in the instruction of trigonometry by considering basic theories of learning and pedagogy. The text first covers the essential elements from elementary algebra, plane geometry, and analytic geometry. Next, the selection tackles the trigonometric functions of angles in general, basic identities, and solutions of equations. The text also deals with the trigonometric functions of real numbers. The fifth chapter details the inverse trigonometric functions