International Nuclear Information System (INIS)
Karthikeyan, Ramamoorthy; Hebert, Alain
2008-01-01
A high conversion light water reactor lattice has been analysed using the code DRAGON Version4. This analysis was performed to test the performance of the advanced self-shielding models incorporated in DRAGON Version4. The self-shielding models are broadly classified into two groups - 'equivalence in dilution' and 'subgroup approach'. Under the 'equivalence in dilution' approach we have analysed the generalized Stamm'ler model with and without Nordheim model and Riemann integration. These models have been analysed also using the Livolant-Jeanpierre normalization. Under the 'subgroup approach', we have analysed Statistical self-shielding model based on physical probability tables and Ribon extended self-shielding model based on mathematical probability tables. This analysis will help in understanding the performance of advanced self-shielding models for a lattice that is tight and has a large fraction of fissions happening in the resonance region. The nuclear data for the analysis was generated in-house. NJOY99.90 was used for generating libraries in DRAGLIB format for analysis using DRAGON and A Compact ENDF libraries for analysis using MCNP5. The evaluated datafiles were chosen based on the recommendations of the IAEA Co-ordinated Research Project on the WIMS Library Update Project. The reference solution for the problem was obtained using Monte Carlo code MCNP5. It was found that the Ribon extended self-shielding model based on mathematical probability tables using correlation model performed better than all other models
Self-shielding models of MICROX-2 code: Review and updates
International Nuclear Information System (INIS)
Hou, J.; Choi, H.; Ivanov, K.N.
2014-01-01
Highlights: • The MICROX-2 code has been improved to expand its application to advanced reactors. • New fine-group cross section libraries based on ENDF/B-VII have been generated. • Resonance self-shielding and spatial self-shielding models have been improved. • The improvements were assessed by a series of benchmark calculations against MCNPX. - Abstract: The MICROX-2 is a transport theory code that solves for the neutron slowing-down and thermalization equations of a two-region lattice cell. The MICROX-2 code has been updated to expand its application to advanced reactor concepts and fuel cycle simulations, including generation of new fine-group cross section libraries based on ENDF/B-VII. In continuation of previous work, the MICROX-2 methods are reviewed and updated in this study, focusing on its resonance self-shielding and spatial self-shielding models for neutron spectrum calculations. The improvement of self-shielding method was assessed by a series of benchmark calculations against the Monte Carlo code, using homogeneous and heterogeneous pin cell models. The results have shown that the implementation of the updated self-shielding models is correct and the accuracy of physics calculation is improved. Compared to the existing models, the updates reduced the prediction error of the infinite multiplication factor by ∼0.1% and ∼0.2% for the homogeneous and heterogeneous pin cell models, respectively, considered in this study
International Nuclear Information System (INIS)
Le Tellier, R.; Hebert, A.
2005-01-01
In this paper, we present the usage of the method of characteristics (MOC) with advanced self-shielding models for a fundamental lattice calculation on an ACR-type cell i.e. a cluster geometry with light water coolant and heavy water moderator. Comparison with the collision probability method (CP) show the consistency of the method of characteristics as implemented both in flux and self-shielding calculations. Acceleration techniques are tested in the different calculations and prove to be efficient. Comparisons with the Monte-Carlo code Tripoli4 show the advantage of a subgroup approach for self-shielding calculations : the difference in k eff is less than one standard deviation of the Tripoli4 calculation and in terms of total absorption rates, in the resolved resonances group, the maximum relative error is of the order of 3% localised in the most outer region of the central pin. (author)
International Nuclear Information System (INIS)
Le Tellier, R.; Hebert, A.; Le Tellier, R.; Santamarina, A.; Litaize, O.
2008-01-01
Calculations based on the characteristics method and different self-shielding models are presented for 9 x 9 boiling water reactor (BWR) assemblies fully loaded with mixed-oxide (MOX) fuel. The geometry of these assemblies was recovered from the BASALA experimental program. We have focused our study on three configurations simulating the different voiding conditions that an assembly can undergo in a BWR pressure vessel. A parametric study was carried out with respect to the spatial discretization, the tracking parameters, and the anisotropy order. Comparisons with Monte Carlo calculations in terms of k eff , radiative capture, and fission rates were performed to validate the computational tools. The results are in good agreement between the stochastic and deterministic approaches. The mutual self-shielding model recently introduced within the framework of the Ribon extending self-shielding method appears to be useful for this type of assemblies. Indeed, in the calculation of these MOX benchmarks, the overlapping of resonances, especially between 238 U and 240 Pu, plays an important role due to the spectral strengthening of the flux as the voiding percentage is increased. The method of characteristics is shown to be adequate to perform accurate calculations handling a fine spatial discretization. (authors)
Advancing Control for Shield Tunneling Machine by Backstepping Design with LuGre Friction Model
Directory of Open Access Journals (Sweden)
Haibo Xie
2014-01-01
Full Text Available Shield tunneling machine is widely applied for underground tunnel construction. The shield machine is a complex machine with large momentum and ultralow advancing speed. The working condition underground is rather complicated and unpredictable, and brings big trouble in controlling the advancing speed. This paper focused on the advancing motion control on desired tunnel axis. A three-state dynamic model was established with considering unknown front face earth pressure force and unknown friction force. LuGre friction model was introduced to describe the friction force. Backstepping design was then proposed to make tracking error converge to zero. To have a comparison study, controller without LuGre model was designed. Tracking simulations of speed regulations and simulations when front face earth pressure changed were carried out to show the transient performances of the proposed controller. The results indicated that the controller had good tracking performance even under changing geological conditions. Experiments of speed regulations were carried out to have validations of the controllers.
International Nuclear Information System (INIS)
Hebert, A.
1997-01-01
The subgroup method is used to compute self-shielded cross sections defined over coarse energy groups in the resolved energy domain. The validity of the subgroup approach was extended beyond the unresolved energy domain by partially taking into account correlation effects between the slowing-down source with the collision probability terms of the transport equation. This approach enables one to obtain a pure subgroup solution of the self-shielding problem without relying on any form of equivalence in dilution. Specific improvements are presented on existing subgroup methods: an N-term rational approximation for the fuel-to-fuel collision probability, a new Pade deflation technique for computing probability tables, and the introduction of a superhomogenization correction. The absorption rates obtained after self-shielding are compared with exact values obtained using an elastic slowing-down calculation where each resonance is modeled individually in the resolved energy domain
Advanced resonance self-shielding method for gray resonance treatment in lattice physics code GALAXY
International Nuclear Information System (INIS)
Koike, Hiroki; Yamaji, Kazuya; Kirimura, Kazuki; Sato, Daisuke; Matsumoto, Hideki; Yamamoto, Akio
2012-01-01
A new resonance self-shielding method based on the equivalence theory is developed for general application to the lattice physics calculations. The present scope includes commercial light water reactor (LWR) design applications which require both calculation accuracy and calculation speed. In order to develop the new method, all the calculation processes from cross-section library preparation to effective cross-section generation are reviewed and reframed by adopting the current enhanced methodologies for lattice calculations. The new method is composed of the following four key methods: (1) cross-section library generation method with a polynomial hyperbolic tangent formulation, (2) resonance self-shielding method based on the multi-term rational approximation for general lattice geometry and gray resonance absorbers, (3) spatially dependent gray resonance self-shielding method for generation of intra-pellet power profile and (4) integrated reaction rate preservation method between the multi-group and the ultra-fine-group calculations. From the various verifications and validations, applicability of the present resonance treatment is totally confirmed. As a result, the new resonance self-shielding method is established, not only by extension of a past concentrated effort in the reactor physics research field, but also by unification of newly developed unique and challenging techniques for practical application to the lattice physics calculations. (author)
New Improvements in Mixture Self-Shielding Treatment with APOLLO2 Code
International Nuclear Information System (INIS)
Coste-Delclaux, M.
2006-01-01
Full text of the presentation follows: APOLLO2 is a modular multigroup transport code developed at the CEA in Saclay (France). Previously, the self-shielding module could only treat one resonant isotope mixed with moderator isotopes. Consequently, the resonant mixture self-shielding treatment was an iterative one. Each resonant isotope of the mixture was treated separately, the other resonant isotopes of the mixture being then considered as moderator isotopes, that is to say non-resonant isotopes. This treatment could be iterated. Recently, we have developed a new method that consists in treating the resonant mixture as a unique entity. A main feature of APOLLO2 self-shielding module is that some implemented models are very general and therefore very powerful and versatile. We can give, as examples, the use of probability tables in order to describe the microscopic cross-section fluctuations or the TR slowing-down model that can deal with any resonance shape. The self-shielding treatment of a resonant mixture was developed essentially thanks to these two models. The goal of this paper is to describe the improvements on the self-shielding treatment of a resonant mixture and to present, as an application, the calculation of the ATRIUM-10 BWR benchmark. We will conclude by some prospects on remaining work in the self-shielding domain. (author)
Enhancement of thermal neutron self-shielding in materials surrounded by reflectors
International Nuclear Information System (INIS)
Cornelia Chilian; Gregory Kennedy
2012-01-01
Materials containing from 41 to 1124 mg chlorine and surrounded by polyethylene containers of various thicknesses, from 0.01 to 5.6 mm, were irradiated in a research reactor neutron spectrum and the 38 Cl activity produced was measured as a function of polyethylene reflector thickness. For the material containing the higher amount of chlorine, the 38 Cl specific activity decreased with increasing reflector thickness, indicating increased neutron self-shielding. It was found that the amount of neutron self-shielding increased by as much as 52% with increasing reflector thickness. This is explained by neutrons which have exited the material subsequently reflecting back into it and thus increasing the total mean path length in the material. All physical and empirical models currently used to predict neutron self-shielding have ignored this effect and need to be modified. A method is given for measuring the adjustable parameter of a self-shielding model for a particular sample size and combination of neutron reflectors. (author)
New improvements in the self-shielding formalism of the Apollo-2 code
International Nuclear Information System (INIS)
Coste, M.; Tellier, H.; Ribon, P.; Raepsaet, V.; Van der Gucht, C.
1993-01-01
One important modelization of a transport code working on a coarse energy mesh is the self-shielding. The French transport code APPOLO 2, developed at the Commissariat a l'Energie Atomique, uses a self-shielding formalism based on a double equivalence. First a homogenization gives the reaction rates in a heterogeneous geometry, and then a multigroup equivalence gives, once the reaction rates are known, the self-shielded cross-sections. The homogenization is a very sensitive part because it is the one which requires physical modelizations. We have added a new model which allows us to treat numerous narrow resonances statistically distributed in the same group of the multigroup mesh. It is important to notice that for a narrow resonance isolated in a group, that new model is equivalent to the previous narrow resonance model (NR)
Revised neutral gas shielding model for pellet ablation - combined neutral and plasma shielding
International Nuclear Information System (INIS)
Houlberg, W.A.; Schuresko, D.D.; Attenberger, S.E.
1986-01-01
The ablation and penetration of pellets in early ORMAK and ISX-A experiments were reliably predicted by the neutral gas shielding model of Milora and Foster. These experiments demonstrated that the principle components of the model - a self-generated shield which reduces the heat flux at the plasma surface - were correct. In more recent experiments with higher temperature plasmas, this model consistently predicts greater penetration than observed in the experiments. Upgarding known limitations of the original model brings the predicted and observed penetration values into agreement. These improvements include: (1) treating the incident electrons as having distribution in energy rather than being monoenergetic; (2) including the shielding effects of cold, dense plasma extending along the magnetic field outside the neutral shield; and (3) modifying the finite plasma, self-limiting incident heat flux so that it represents a collisionless plasma limit rather than a collisional limit. Comparisons are made between the models for a selection of ISX-B Alcator-C, and TFTR shots. The net effect of the changes in the model is an increase in pellet ablation rates and decrease in penetration for current and future experiments
Neutral and plasma shielding model for pellet ablation
International Nuclear Information System (INIS)
Houlberg, W.A.; Milora, S.L.; Attenberger, S.E.
1987-10-01
The neutral gas shielding model for ablation of frozen hydrogenic pellets is extended to include the effects of an initial Maxwelliam distribution of incident electron energies; a cold plasma shield outside the neutral shield and extended along the magnetic field; energetic neutral beam ions and alpha particles; and self-limiting electron ablation in the collisionless plasma limit. Including the full electron distribution increases ablation, but adding the cold ionized shield reduces ablation; the net effect is a modest reduction in pellet penetration compared with the monoenergetic electron neutral shielding model with no plasma shield. Unlike electrons, fast ions can enter the neutral shield directly without passing through the cold ionized shield because their gyro-orbits are typically larger than the diameter of the cold plasma tube. Fast alpha particles should not enhance the ablation rate unless their population exceeds that expected from local classical thermalization. Fast beam ions, however, may enhance ablation in the plasma periphery if their population is high enough. Self-limiting ablation in the collisionless limit leads to a temporary distortion of the original plasma electron Maxwellian distribution function through preferential depopulation of the higher-energy electrons. 23 refs., 9 figs
Self-shielding characteristics of aqueous self-cooled blankets for next generation fusion devices
International Nuclear Information System (INIS)
Pelloni, S.; Cheng, E.T.; Embrechts, M.J.
1987-11-01
The present study examines self-shielding characteristics for two aqueous self-cooled tritium producing driver blankets for next generation fusion devices. The aqueous Self-Cooled Blanket concept (ASCB) is a very simple blanket concept that relies on just structural material and coolant. Lithium compounds are dissolved in water to provide for tritium production. An ASCB driver blanket would provide a low technology and low temperature environment for blanket test modules in a next generation fusion reactor. The primary functions of such a blanket would be shielding, energy removal and tritium production. One driver blanket considered in this study concept relates to the one proposed for the Next European Torus (NET), while the second concept is indicative for the inboard shield design for the Engineering Test Reactor proposed by the USA (TIBER II/ETR). The driver blanket for NET is based on stainless steel for the structural material and aqueous solution, while the inboard shielding blanket for TIBER II/ETR is based on a tungsten/aqueous solution combination. The purpose of this study is to investigate self-shielding and heterogeneity effects in aqueous self-cooled blankets. It is found that no significant gains in tritium breeding can be achieved in the stainless steel blanket if spatial and energy self-shielding effects are considered, and the heterogeneity effects are also insignificant. The tungsten blanket shows a 5 percent increase in tritium production in the shielding blanket when energy and spatial self-shielding effects are accounted for. However, the tungsten blanket shows a drastic increase in the tritium breeding ratio due to heterogeneity effects. (author) 17 refs., 9 figs., 9 tabs
International Nuclear Information System (INIS)
Downar, T.
2009-01-01
The overall objective of the work here has been to eliminate the approximations used in current resonance treatments by developing continuous energy multi-dimensional transport calculations for problem dependent self-shielding calculations. The work here builds on the existing resonance treatment capabilities in the ORNL SCALE code system. The overall objective of the work here has been to eliminate the approximations used in current resonance treatments by developing continuous energy multidimensional transport calculations for problem dependent self-shielding calculations. The work here builds on the existing resonance treatment capabilities in the ORNL SCALE code system. Specifically, the methods here utilize the existing continuous energy SCALE5 module, CENTRM, and the multi-dimensional discrete ordinates solver, NEWT to develop a new code, CENTRM( ) NEWT. The work here addresses specific theoretical limitations in existing CENTRM resonance treatment, as well as investigates advanced numerical and parallel computing algorithms for CENTRM and NEWT in order to reduce the computational burden. The result of the work here will be a new computer code capable of performing problem dependent self-shielding analysis for both existing and proposed GENIV fuel designs. The objective of the work was to have an immediate impact on the safety analysis of existing reactors through improvements in the calculation of fuel temperature effects, as well as on the analysis of more sophisticated GENIV/NGNP systems through improvements in the depletion/transmutation of actinides for Advanced Fuel Cycle Initiatives.
Energy Technology Data Exchange (ETDEWEB)
Videira, Heber S.; Burkhardt, Guilherme M.; Santos, Ronielly S., E-mail: heber@cyclopet.com.br [Cyclopet Radiofarmacos Ltda., Curitiba, PR (Brazil); Passaro, Bruno M.; Gonzalez, Julia A.; Santos, Josefina; Guimaraes, Maria I.C.C. [Universidade de Sao Paulo (HCFMRP/USP), Sao Paulo, SP (Brazil). Faculdade de Medicina. Hospital das Clinicas; Lenzi, Marcelo K. [Universidade Federal do Parana (UFPR), Curitina (Brazil). Programa de Pos-Graduacao em Engenharia Quimica
2013-04-15
The technological advances in positron emission tomography (PET) in conventional clinic imaging have led to a steady increase in the number of cyclotrons worldwide. Most of these cyclotrons are being used to produce {sup 18}F-FDG, either for themselves as for the distribution to other centers that have PET. For there to be safety in radiological facilities, the cyclotron intended for medical purposes can be classified in category I and category II, ie, self-shielded or non-shielded (bunker). Therefore, the aim of this work is to verify the effectiveness of borated water shield built for a cyclotron accelerator-type Self-shielded PETtrace 860. Mixtures of water borated occurred in accordance with the manufacturer’s specifications, as well as the results of the radiometric survey in the vicinity of the self-shielding of the cyclotron in the conditions established by the manufacturer showed that radiation levels were below the limits. (author)
ICRF antenna Faraday shield plasma sheath model
International Nuclear Information System (INIS)
Whealton, J.H.; Ryan, P.M.; Raridon, R.J.
1990-01-01
A two-dimensional nonlinear formulation that explicitly considers the plasma edge near a Faraday shield in a self-consistent manner is used in the modeling of the ion motion for a Faraday shield concept and model suggested by Perkins. Two models are considered that may provide significant insight into the generation of impurities for ion cyclotron resonance heating (ICRH) antennas. In one of these models a significant sheath periodically forms next to the Faraday screen, with ion acoustic waves heating the ions in the plasma. (orig.)
Development of advanced, non-toxic, synthetic radiation shielding aggregate
Energy Technology Data Exchange (ETDEWEB)
Mudgal, Manish; Chouhan, Ramesh Kumar; Verma, Sarika; Amritphale, Sudhir Sitaram; Das, Satyabrata [CSIR-Advanced Materials and Processes Research Institute, Bhopal (India); Shrivastva, Arvind [Nuclear Power Corporation of India Ltd. (NPCIL), Mumbai (India)
2018-04-01
For the first time in the world, the capability of red mud waste has been explored for the development of advanced synthetic radiation shielding aggregate. Red mud, an aluminium industry waste consists of multi component, multi elemental characteristics. In this study, red mud from two different sources have been utilized. Chemical formulation and mineralogical designing of the red mud has been done by ceramic processing using appropriate reducing agent and additives. The chemical analysis, SEM microphotographs and XRD analysis confirms the presence of multi-component, multi shielding and multi-layered phases in both the different developed advance synthetic radiation shielding aggregate. The mechanical properties, namely aggregate impact value, aggregate crushing value and aggregate abrasion value have also been evaluated and was compared with hematite ore aggregate and found to be an excellent material useful for making advanced radiation shielding concrete for the construction of nuclear power plants and other radiation installations.
SUBGR: A Program to Generate Subgroup Data for the Subgroup Resonance Self-Shielding Calculation
Energy Technology Data Exchange (ETDEWEB)
Kim, Kang Seog [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)
2016-06-06
The Subgroup Data Generation (SUBGR) program generates subgroup data, including levels and weights from the resonance self-shielded cross section table as a function of background cross section. Depending on the nuclide and the energy range, these subgroup data can be generated by (a) narrow resonance approximation, (b) pointwise flux calculations for homogeneous media; and (c) pointwise flux calculations for heterogeneous lattice cells. The latter two options are performed by the AMPX module IRFFACTOR. These subgroup data are to be used in the Consortium for Advanced Simulation of Light Water Reactors (CASL) neutronic simulator MPACT, for which the primary resonance self-shielding method is the subgroup method.
Self-Shielding Treatment to Perform Cell Calculation for Seed Furl In Th/U Pwr Using Dragon Code
Directory of Open Access Journals (Sweden)
Ahmed Amin El Said Abd El Hameed
2015-08-01
Full Text Available Time and precision of the results are the most important factors in any code used for nuclear calculations. Despite of the high accuracy of Monte Carlo codes, MCNP and Serpent, in many cases their relatively long computational time leads to difficulties in using any of them as the main calculation code. Usually, Monte Carlo codes are used only to benchmark the results. The deterministic codes, which are usually used in nuclear reactor’s calculations, have limited precision, due to the approximations in the methods used to solve the multi-group transport equation. Self- Shielding treatment, an algorithm that produces an average cross-section defined over the complete energy domain of the neutrons in a nuclear reactor, is responsible for the biggest error in any deterministic codes. There are mainly two resonance self-shielding models commonly applied: models based on equivalence and dilution and models based on subgroup approach. The fundamental problem with any self-shielding method is that it treats any isotope as there are no other isotopes with resonance present in the reactor. The most practical way to solve this problem is to use multi-energy groups (50-200 that are chosen in a way that allows us to use all major resonances without self-shielding. In this paper, we perform cell calculations, for a fresh seed fuel pin which is used in thorium/uranium reactors, by solving 172 energy group transport equation using the deterministic DRAGON code, for the two types of self-shielding models (equivalence and dilution models and subgroup models Using WIMS-D5 and DRAGON data libraries. The results are then tested by comparing it with the stochastic MCNP5 code. We also tested the sensitivity of the results to a specific change in self-shielding method implemented, for example the effect of applying Livolant-Jeanpierre Normalization scheme and Rimman Integration improvement on the equivalence and dilution method, and the effect of using Ribbon
Uncertainty Analysis with Considering Resonance Self-shielding Effect
Energy Technology Data Exchange (ETDEWEB)
Han, Tae Young [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)
2016-10-15
If infinitely diluted multi-group cross sections were used for the sensitivity, the covariance data from the evaluated nuclear data library (ENDL) was directly applied. However, in case of using a self-shielded multi-group cross section, the covariance data should be corrected considering self-shielding effect. Usually, implicit uncertainty can be defined as the uncertainty change by the resonance self-shielding effect as described above. MUSAD ( Modules of Uncertainty and Sensitivity Analysis for DeCART ) has been developed for a multiplication factor and cross section uncertainty based on the generalized perturbation theory and it, however, can only quantify the explicit uncertainty by the self-shielded multi-group cross sections without considering the implicit effect. Thus, this paper addresses the implementation of the implicit uncertainty analysis module into the code and the numerical results for the verification are provided. The implicit uncertainty analysis module has been implemented into MUSAD based on infinitely-diluted cross section-based consistent method. The verification calculation was performed on MHTGR 350 Ex.I-1a and the differences with McCARD result decrease from 40% to 1% in CZP case and 3% in HFP case. From this study, it is expected that MUSAD code can reasonably produce the complete uncertainty on VHTR or LWR where the resonance self-shielding effect should be significantly considered.
Uncertainty Analysis with Considering Resonance Self-shielding Effect
International Nuclear Information System (INIS)
Han, Tae Young
2016-01-01
If infinitely diluted multi-group cross sections were used for the sensitivity, the covariance data from the evaluated nuclear data library (ENDL) was directly applied. However, in case of using a self-shielded multi-group cross section, the covariance data should be corrected considering self-shielding effect. Usually, implicit uncertainty can be defined as the uncertainty change by the resonance self-shielding effect as described above. MUSAD ( Modules of Uncertainty and Sensitivity Analysis for DeCART ) has been developed for a multiplication factor and cross section uncertainty based on the generalized perturbation theory and it, however, can only quantify the explicit uncertainty by the self-shielded multi-group cross sections without considering the implicit effect. Thus, this paper addresses the implementation of the implicit uncertainty analysis module into the code and the numerical results for the verification are provided. The implicit uncertainty analysis module has been implemented into MUSAD based on infinitely-diluted cross section-based consistent method. The verification calculation was performed on MHTGR 350 Ex.I-1a and the differences with McCARD result decrease from 40% to 1% in CZP case and 3% in HFP case. From this study, it is expected that MUSAD code can reasonably produce the complete uncertainty on VHTR or LWR where the resonance self-shielding effect should be significantly considered
Computing Moment-Based Probability Tables for Self-Shielding Calculations in Lattice Codes
International Nuclear Information System (INIS)
Hebert, Alain; Coste, Mireille
2002-01-01
As part of the self-shielding model used in the APOLLO2 lattice code, probability tables are required to compute self-shielded cross sections for coarse energy groups (typically with 99 or 172 groups). This paper describes the replacement of the multiband tables (typically with 51 subgroups) with moment-based tables in release 2.5 of APOLLO2. An improved Ribon method is proposed to compute moment-based probability tables, allowing important savings in CPU resources while maintaining the accuracy of the self-shielding algorithm. Finally, a validation is presented where the absorption rates obtained with each of these techniques are compared with exact values obtained using a fine-group elastic slowing-down calculation in the resolved energy domain. Other results, relative to the Rowland's benchmark and to three assembly production cases, are also presented
Shielding analysis of the advanced voloxidation process
Energy Technology Data Exchange (ETDEWEB)
Park, Chang Je; Park, J. J.; Lee, J. W.; Shin, J. M.; Park, G. I.; Song, K. C
2008-09-15
This report deals describes how much a shielding benefit can be obtained by the Advanced Voloxidation process. The calculation was performed with the MCNPX code and a simple problem was modeled with a spent fuel source which was surrounded by a concrete wall. The source terms were estimated with the ORIGEN-ARP code and the gamma spectrum and the neutron spectrum were also obtained. The thickness of the concrete wall was estimated before and after the voloxidation process. From the results, the gamma spectrum after the voloxidation process was estimated as a 67% reduction compared with that of before the voloxidation process due to the removal of several gamma emission elements such as cesium and rubidium. The MCNPX calculations provided that the thickness of the general concrete wall could be reduced by 12% after the voloxidation process. And the heavy concrete wall provided a 28% reduction in the shielding of the source term after the voloxidation process. This can be explained in that there lots of gamma emission isotopes still exist after the advanced voloxidation process such as Pu-241, Y-90, and Sr-90 which are independent of the voloxidation process.
Self-Shielding Of Transmission Lines
Energy Technology Data Exchange (ETDEWEB)
Christodoulou, Christos [Univ. of New Mexico, Albuquerque, NM (United States)
2017-03-01
The use of shielding to contend with noise or harmful EMI/EMR energy is not a new concept. An inevitable trade that must be made for shielding is physical space and weight. Space was often not as much of a painful design trade in older larger systems as they are in today’s smaller systems. Today we are packing in an exponentially growing number of functionality within the same or smaller volumes. As systems become smaller and space within systems become more restricted, the implementation of shielding becomes more problematic. Often, space that was used to design a more mechanically robust component must be used for shielding. As the system gets smaller and space is at more of a premium, the trades starts to result in defects, designs with inadequate margin in other performance areas, and designs that are sensitive to manufacturing variability. With these challenges in mind, it would be ideal to maximize attenuation of harmful fields as they inevitably couple onto transmission lines without the use of traditional shielding. Dr. Tom Van Doren proposed a design concept for transmission lines to a class of engineers while visiting New Mexico. This design concept works by maximizing Electric field (E) and Magnetic Field (H) field containment between operating transmission lines to achieve what he called “Self-Shielding”. By making the geometric centroid of the outgoing current coincident with the return current, maximum field containment is achieved. The reciprocal should be true as well, resulting in greater attenuation of incident fields. Figure’s 1(a)-1(b) are examples of designs where the current centroids are coincident. Coax cables are good examples of transmission lines with co-located centroids but they demonstrate excellent field attenuation for other reasons and can’t be used to test this design concept. Figure 1(b) is a flex circuit design that demonstrate the implementation of self-shielding vs a standard conductor layout.
MPACT Subgroup Self-Shielding Efficiency Improvements
International Nuclear Information System (INIS)
Stimpson, Shane; Liu, Yuxuan; Collins, Benjamin S.; Clarno, Kevin T.
2016-01-01
Recent developments to improve the efficiency of the MOC solvers in MPACT have yielded effective kernels that loop over several energy groups at once, rather that looping over one group at a time. These kernels have produced roughly a 2x speedup on the MOC sweeping time during eigenvalue calculation. However, the self-shielding subgroup calculation had not been reevaluated to take advantage of these new kernels, which typically requires substantial solve time. The improvements covered in this report start by integrating the multigroup kernel concepts into the subgroup calculation, which are then used as the basis for further extensions. The next improvement that is covered is what is currently being termed as ''Lumped Parameter MOC''. Because the subgroup calculation is a purely fixed source problem and multiple sweeps are performed only to update the boundary angular fluxes, the sweep procedure can be condensed to allow for the instantaneous propagation of the flux across a spatial domain, without the need to sweep along all segments in a ray. Once the boundary angular fluxes are considered to be converged, an additional sweep that will tally the scalar flux is completed. The last improvement that is investigated is the possible reduction of the number of azimuthal angles per octant in the shielding sweep. Typically 16 azimuthal angles per octant are used for self-shielding and eigenvalue calculations, but it is possible that the self-shielding sweeps are less sensitive to the number of angles than the full eigenvalue calculation.
Self-shielding effect in unresolved resonance data in JENDL-4.0
International Nuclear Information System (INIS)
Konno, Chikara; Takakura, Kosuke; Ochiai, Kentaro; Sato, Satoshi; Kato, Yoshinari
2012-01-01
At International Conference on Nuclear Data for Science and Technology in 2007 we pointed out that most of unresolved resonance data in JENDL-3.3 have a problem related to self-shielding correction. Here with a simple calculation model we have investigated whether the latest JENDL, JENDL-4.0, was improved for the problem or not. The results suggest that unresolved resonance data in JENDL-4.0 have no problem, but it seems that self-shielding effects for the unresolved resonance data in JENDL-4.0 are too large. New benchmark experiments for unresolved resonance data are strongly recommended in order to verify unresolved resonance data. (author)
Characteristic Determination Of Self Shielding Factor And Cadmium Ratio Of Cylindrical Probe
International Nuclear Information System (INIS)
Hamzah, Amir; Budi R, Ita; Pinem, Suriam
1996-01-01
Determination of thermal, epithermal and total self shielding factor and cadmium ratio of cylindrical probe has been done by measurement and calculation. Self shielding factor can be determined by dividing probe activity to Al-alloy probe activity. Due to the lack of cylindrical probe made of Al-alloy, self shielding factor can be determined by parabolic extrapolation of measured activities to 0 cm radius to divide those activities. Theoretically, self shielding factor can be determined by making numerical solution of two dimensional integral equations using Romberg method. To simplify, the calculation is based on single collision theory with the assumption of monoenergetic neutron and isotropic distribution. For gold cylindrical probe, the calculation results are quite close to the measurement one with the relative discrepancy for activities, cadmium ratio and self shielding factor of bare probe are less then 11.5%, 3,5% and 1.5% respectively. The program can be used for the calculation of other kinds of cylindrical probes. Due to dependency to radius, cylindrical probe made of copper has the best characteristic of self shielding factor and cadmium ratio
ICRF Faraday shield plasma sheath models: Low and high conductivity limits
International Nuclear Information System (INIS)
Whealton, J.H.; Ryan, P.M.; Raridon, R.J.
1989-01-01
Using a 2-D nonlinear formulation which explicitly considers the plasma edge near a Faraday shield in a self consistent manner, progress is indicated in the modeling of the ion motion for a Faraday shield concept and model suggested by Perkins. Several models are considered which may provide significant insight into the impurities generation for ICRH antennas. 6 refs., 8 figs
Monte Carlo validation of self shielding and void effect calculations
International Nuclear Information System (INIS)
Tellier, H.; Coste, M.; Raepsaet, C.; Soldevila, M.; Van der Gucht, C.
1995-01-01
The self shielding validation and the void effect are studied with Monte Carlo method. The satisfactory comparison obtained between the APOLLO 2 results of the self shielding effect and the TRIPOLI and MCNP results allows us to be confident in the multigroup transport code. (K.A.)
A new formulation for resonance self-shielding factors
International Nuclear Information System (INIS)
Palma, Daniel A.P.; Martinez, Aquilino S.; Silva, Fernando C. da
2007-01-01
The activation technique allows either absolute or relative very precise neutron intensity measurements. This technique requires the knowledge of the Doppler broadening function to determine resonance self-shielding factors. In the present work a new formulation is proposed for the self-shielding factors where the Doppler broadening function is calculated using the Frobenius's method and compared to the values obtained from the four-pole Pade method. This calculation method is shown to be effective from the point of view of accuracy. (author)
Self-shielding for thick slabs in a converging neutron beam
Mildner, D F R
1999-01-01
We have previously given a correction to the neutron self-shielding for a thin slab to account for the increased average path length through the slab when irradiated in a converging neutron beam. This expression overstates the case for the self-shielding for a thick (or highly absorbing) slab. We give a better approximation to the increase in effective shielding correction for a slab placed in a converging neutron beam. It is negligible at large absorption mean free paths. (author)
A new formulation for resonance self-shielding factors
Energy Technology Data Exchange (ETDEWEB)
Palma, Daniel A.P.; Martinez, Aquilino S.; Silva, Fernando C. da [Universidade Federal, Rio de Janeiro, RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia. Programa de Engenharia Nuclear]. E-mail: aquilino@lmp.ufrj.br
2007-07-01
The activation technique allows either absolute or relative very precise neutron intensity measurements. This technique requires the knowledge of the Doppler broadening function to determine resonance self-shielding factors. In the present work a new formulation is proposed for the self-shielding factors where the Doppler broadening function is calculated using the Frobenius's method and compared to the values obtained from the four-pole Pade method. This calculation method is shown to be effective from the point of view of accuracy. (author)
International Nuclear Information System (INIS)
Tzika, F.; Stamatelatos, I.E.
2004-01-01
Thermal neutron self-shielding within large samples was studied using the Monte Carlo neutron transport code MCNP. The code enabled a three-dimensional modeling of the actual source and geometry configuration including reactor core, graphite pile and sample. Neutron flux self-shielding correction factors derived for a set of materials of interest for large sample neutron activation analysis are presented and evaluated. Simulations were experimentally verified by measurements performed using activation foils. The results of this study can be applied in order to determine neutron self-shielding factors of unknown samples from the thermal neutron fluxes measured at the surface of the sample
Insufficient self-shielding correction in VITAMIN-B6
International Nuclear Information System (INIS)
Konno, Chikara; Ochiai, Kentaro; Ohnishi, Seiki
2011-01-01
We carried out a simple benchmark calculation test with a multigroup cross-section library VITAMIN-B6 generated from ENDF/B-VI. The model of this test consisted of an iron sphere of 1 m in radius with an isotropic 20 MeV neutron source in the center. Neutron spectra in the sphere were calculated with an Sn code ANISN and VITAMIN-B6 or FENDL/MG-1.1. A calculation with MCNP and ENDF/B-VI was carried out as a reference. The neutron spectra with ANISN and FENDL/MG-1.1 agreed with those with MCNP, while those with ANISN and VITAMIN-B6 were at most 50% different from those with MCNP. We uncovered that the discrepancy came from insufficient self-shielding correction due to the followings; 1) The smallest background cross section of 56 Fe in VITAMIN-B6 is 1. 2) The weighting flux used in generating VITAMIN-B6 is not adequate. VITAMIN-B6 should be revised for adequate self-shielding correction. (author)
DiJulio, D. D.; Cooper-Jensen, C. P.; Llamas-Jansa, I.; Kazi, S.; Bentley, P. M.
2018-06-01
A combined measurement and Monte-Carlo simulation study was carried out in order to characterize the particle self-shielding effect of B4C grains in neutron shielding concrete. Several batches of a specialized neutron shielding concrete, with varying B4C grain sizes, were exposed to a 2 Å neutron beam at the R2D2 test beamline at the Institute for Energy Technology located in Kjeller, Norway. The direct and scattered neutrons were detected with a neutron detector placed behind the concrete blocks and the results were compared to Geant4 simulations. The particle self-shielding effect was included in the Geant4 simulations by calculating effective neutron cross-sections during the Monte-Carlo simulation process. It is shown that this method well reproduces the measured results. Our results show that shielding calculations for low-energy neutrons using such materials would lead to an underestimate of the shielding required for a certain design scenario if the particle self-shielding effect is not included in the calculations.
The problem of resonance self-shielding effect in neutron multigroup calculations
International Nuclear Information System (INIS)
Wang Qingming; Huang Jinghua
1991-01-01
It is not allowed to neglect the resonance self-shielding effect in hybrid blanket and fast reactor neutron designs. The authors discussed the importance as well as the method of considering the resonance self-shielding effect in hybrid blanket and fast reactor neutron multigroup calculations
Self-shielding of hydrogen in the IGM during the epoch of reionization
Chardin, Jonathan; Kulkarni, Girish; Haehnelt, Martin G.
2018-04-01
We investigate self-shielding of intergalactic hydrogen against ionizing radiation in radiative transfer simulations of cosmic reionization carefully calibrated with Lyα forest data. While self-shielded regions manifest as Lyman-limit systems in the post-reionization Universe, here we focus on their evolution during reionization (redshifts z = 6-10). At these redshifts, the spatial distribution of hydrogen-ionizing radiation is highly inhomogeneous, and some regions of the Universe are still neutral. After masking the neutral regions and ionizing sources in the simulation, we find that the hydrogen photoionization rate depends on the local hydrogen density in a manner very similar to that in the post-reionization Universe. The characteristic physical hydrogen density above which self-shielding becomes important at these redshifts is about nH ˜ 3 × 10-3 cm-3, or ˜20 times the mean hydrogen density, reflecting the fact that during reionization photoionization rates are typically low enough that the filaments in the cosmic web are often self-shielded. The value of the typical self-shielding density decreases by a factor of 3 between redshifts z = 3 and 10, and follows the evolution of the average photoionization rate in ionized regions in a simple fashion. We provide a simple parameterization of the photoionization rate as a function of density in self-shielded regions during the epoch of reionization.
Resonance Self-Shielding Methodologies in SCALE 6
International Nuclear Information System (INIS)
Williams, Mark L.
2011-01-01
SCALE 6 includes several problem-independent multigroup (MG) libraries that were processed from the evaluated nuclear data file ENDF/B using a generic flux spectrum. The library data must be self-shielded and corrected for problem-specific spectral effects for use in MG neutron transport calculations. SCALE 6 computes problem-dependent MG cross sections through a combination of the conventional Bondarenko shielding-factor method and a deterministic continuous-energy (CE) calculation of the fine-structure spectra in the resolved resonance and thermal energy ranges. The CE calculation can be performed using an infinite medium approximation, a simplified two-region method for lattices, or a one-dimensional discrete ordinates transport calculation with pointwise (PW) cross-section data. This paper describes the SCALE-resonance self-shielding methodologies, including the deterministic calculation of the CE flux spectra using PW nuclear data and the method for using CE spectra to produce problem-specific MG cross sections for various configurations (including doubly heterogeneous lattices). It also presents results of verification and validation studies.
Revisiting the stamm'ler self-shielding method
International Nuclear Information System (INIS)
Hebert, A.
2004-01-01
The generalized Stamm'ler method is been used in lattice codes such as PHOENIX, WIMS-AECL and DRAGON-IST for computing self-shielded cross sections, prior to the main flux calculation. This method is handicapped by deficiencies, such as its low accuracy and its inability to represent distributed self-shielding effects in a fuel rod or across a fuel bundle. The paper describes improvements that could be made to the generalized Stamm'ler method in order to mitigate these two defects. A validation is presented for the case of 238 U nuclides located in different geometries. The isotopic absorption rates obtained with the proposed numerical scheme are compared with exact values obtained with a fine-group elastic slowing-down calculation in the resolved energy domain. (author)
Technology development for radiation shielding analysis
International Nuclear Information System (INIS)
Ha, Jung Woo; Lee, Jae Kee; Kim, Jong Kyung
1986-12-01
Radiation shielding analysis in nuclear engineering fields is an important technology which is needed for the calculation of reactor shielding as well as radiation related safety problems in nuclear facilities. Moreover, the design technology required in high level radioactive waste management and disposal facilities is faced on serious problems with rapidly glowing nuclear industry development, and more advanced technology has to be developed for tomorrow. The main purpose of this study is therefore to build up the self supporting ability of technology development for the radiation shielding analysis in order to achieve successive development of nuclear industry. It is concluded that basic shielding calculations are possible to handle and analyze by using our current technology, but more advanced technology is still needed and has to be learned for the degree of accuracy in two-dimensional shielding calculation. (Author)
Uranium self-shielding in fast reactor blankets
Energy Technology Data Exchange (ETDEWEB)
Kadiroglu, O.K.; Driscoll, M.J.
1976-03-01
The effects of heterogeneity on resonance self-shielding are examined with particular emphasis on the blanket region of the fast breeder reactor and on its dominant reaction--capture in /sup 238/U. The results, however, apply equally well to scattering resonances, to other isotopes (fertile, fissile and structural species) and to other environments, so long as the underlying assumptions of narrow resonance theory apply. The heterogeneous resonance integral is first cast into a modified homogeneous form involving the ratio of coolant-to-fuel fluxes. A generalized correlation (useful in its own right in many other applications) is developed for this ratio, using both integral transport and collision probability theory to infer the form of correlation, and then relying upon Monte Carlo calculations to establish absolute values of the correlation coefficients. It is shown that a simple linear prescription can be developed for the flux ratio as a function of only fuel optical thickness and the fraction of the slowing-down source generated by the coolant. This in turn permitted derivation of a new equivalence theorem relating the heterogeneous self-shielding factor to the homogeneous self-shielding factor at a modified value of the background scattering cross section per absorber nucleus. A simple version of this relation is developed and used to show that heterogeneity has a negligible effect on the calculated blanket breeding ratio in fast reactors.
Neutron self-shielding with k0-NAA irradiations
International Nuclear Information System (INIS)
Chilian, C.; Chambon, R.; Kennedy, G.
2010-01-01
A sample of SMELS Type II reference material was mixed with powdered Cd-nitrate neutron absorber and analysed by k 0 NAA for 10 elements. The thermal neutron self-shielding effect was found to be 34.8%. When flux monitors were irradiated sufficiently far from the absorbing sample, it was found that the self-shielding could be corrected accurately using an analytical formula and an iterative calculation. When the flux monitors were irradiated 2 mm from the absorbing sample, the calculations over-corrected the concentrations by as much as 30%. It is recommended to irradiate flux monitors at least 14 mm from a 10 mm diameter absorbing sample.
URR-PACK: Calculating Self-Shielding in the Unresolved Resonance Energy Range
International Nuclear Information System (INIS)
Cullen, Dermott E.; Trkov, Andrej
2016-07-01
This report describes HOW to calculate self-shielding in the unresolved resonance region (URR), in terms of the computer codes we provide to allow a user to do these calculations himself. Here we only describe HOW to calculate; a longer companion report describes in detail WHY it is necessary to include URR self-shielding.
Neutronics investigation of advanced self-cooled liquid blanket systems in helical reactor
International Nuclear Information System (INIS)
Tanaka, T.; Sagara, A.; Muroga, T.; Youssef, M.Z.
2006-10-01
Neutronics performances of advanced self-cooled liquid blanket systems have been investigated in design activity of the helical-type reactor FFHR2. In the present study, a new three-dimensional (3-D) neutronics calculation system has been developed for the helical-type reactor to enhance quick feedback between neutronics evaluation and design modification. Using this new calculation system, advanced Flibe-cooled and Li-cooled liquid blanket systems proposed for FFHR2 have been evaluated to make clear design issues to enhance neutronics performance. Based on calculated results, modification of the blanket dimensions and configuration have been attempted to achieve the adequate tritium breeding ability and neutron shielding performance in the helical reactor. The total tritium breeding ratios (TBRs) obtained after modifying the blanket dimensions indicated that all the advanced blanket systems proposed for FFHR2 would achieve adequate tritium self-sufficiency by dimension adjustment and optimization of structures in the breeder layers. Issues in neutron shielding performance have been investigated quantitatively using 3-D geometry of the helical blanket system, support structures, poloidal coils etc. Shielding performance of the helical coils against direct neutrons from core plasma would achieve design target by further optimization of shielding materials. However, suppression of the neutron streaming and reflection through the divertor pumping areas in the original design is important issue to protect the poloidal coils and helical coils, respectively. Investigation of the neutron wall loading indicated that the peaking factor of the neutron wall load distribution would be moderated by the toroidal and helical effect of the plasma distribution in the helical reactor. (author)
Self shielding in cylindrical fissile sources in the APNea system
International Nuclear Information System (INIS)
Hensley, D.
1997-01-01
In order for a source of fissile material to be useful as a calibration instrument, it is necessary to know not only how much fissile material is in the source but also what the effective fissile content is. Because uranium and plutonium absorb thermal neutrons so Efficiently, material in the center of a sample is shielded from the external thermal flux by the surface layers of the material. Differential dieaway measurements in the APNea System of five different sets of cylindrical fissile sources show the various self shielding effects that are routinely encountered. A method for calculating the self shielding effect is presented and its predictions are compared with the experimental results
Theoretical evaluation of self-shielding factors due to scattering resonances in foils
International Nuclear Information System (INIS)
Selander, W.N.
1960-06-01
A semi-analytical method is given for evaluating self-shielding factors for activation measurements which use thin foils having neutron scattering resonances. The energy loss by scattering in the foil is taken into account. The energy-dependent neutron angular distribution is expanded as a double series, the coefficients of which are (energy dependent) solutions of an infinite set of coupled integral equations. These are truncated in some suitable manner and solved numerically. The leading term of the series is proportional to the average, or effective flux in the activation sample. The product of this terra and the neutron capture cross-section is integrated numerically over the resonance to give the resonance self-shielding correction. Figure 4 shows resonance self-shielding factors derived in this mariner for the 132ev resonance in Co-59 and figure 5 shows similar results for the two Mn-55 resonances at 337ev and 1080ev. Self-shielding factors for 1/v capture are not significantly different from unity. (author)
Energy Technology Data Exchange (ETDEWEB)
Coste-Delclaux, M
2006-03-15
This document describes the improvements carried out for modelling the self-shielding phenomenon in the multigroup transport code APOLLO2. They concern the space and energy treatment of the slowing-down equation, the setting up of quadrature formulas to calculate reaction rates, the setting-up of a method that treats directly a resonant mixture and the development of a sub-group method. We validate these improvements either in an elementary or in a global way. Now, we obtain, more accurate multigroup reaction rates and we are able to carry out a reference self-shielding calculation on a very fine multigroup mesh. To end, we draw a conclusion and give some prospects on the remaining work. (author)
International Nuclear Information System (INIS)
Nasrabadi, M.N.; Mohammadi, A.; Jalali, M.
2009-01-01
In this paper bulk sample prompt gamma neutron activation analysis (BSPGNAA) was applied to aqueous sample analysis using a relative method. For elemental analysis of an unknown bulk sample, gamma self-shielding coefficient was required. Gamma self-shielding coefficient of unknown samples was estimated by an experimental method and also by MCNP code calculation. The proposed methodology can be used for the determination of the elemental concentration of unknown aqueous samples by BSPGNAA where knowledge of the gamma self-shielding within the sample volume is required.
Energy Technology Data Exchange (ETDEWEB)
Coste-Delclaux, M
2006-03-15
This document describes the improvements carried out for modelling the self-shielding phenomenon in the multigroup transport code APOLLO2. They concern the space and energy treatment of the slowing-down equation, the setting up of quadrature formulas to calculate reaction rates, the setting-up of a method that treats directly a resonant mixture and the development of a sub-group method. We validate these improvements either in an elementary or in a global way. Now, we obtain, more accurate multigroup reaction rates and we are able to carry out a reference self-shielding calculation on a very fine multigroup mesh. To end, we draw a conclusion and give some prospects on the remaining work. (author)
International Nuclear Information System (INIS)
Fitzpatrick, J.; Verrall, S.M.
1985-01-01
A comparative study has been carried out on the two philosophies for providing the radiological protection necessary for the transport and handling of packaged intermediate level wastes from their sites of origin to disposal. The two philosophies are self shielding and returnable shielding. The approach taken was to assess the cost and radiological impact differentials of two respective representative waste management procedures. The comparison indicated the merits of each procedure. As a consequence, a hybrid procedure was identified which combines the advantages of each philosophy. This hybrid procedure was used for further comparison. The results of the study indicate that the use of self shielded packages throughout will incur considerable extra expense and give only a small saving in radiological impact. (author)
Radiation monitoring in a self-shielded cyclotron installation
International Nuclear Information System (INIS)
Capaccioli, L.; Gori, C.; Mazzocchi, S.; Spano, G.
2002-01-01
As nuclear medicine is approaching a new era with the spectacular growth of PET diagnosis, the number of medical cyclotrons installed within the major hospitals is increasing accordingly. Therefore modern medical cyclotron are highly engineered and highly reliable apparatus, characterised with reduced accelerating energies (as the major goal is the production of fluorine 18) and often self-shielded. However specific dedicated monitors are still necessary in order to assure the proper radioprotection. At the Careggi University Hospital in Florence a Mini trace 10 MeV self-shielded cyclotron produced by General Electric has been installed in 2000. In a contiguous radiochemistry laboratory, the preparation and quality control of 1 8F DG and other radiopharmaceuticals takes place. Aim of this work is the characterisation and the proper calibration of the above mentioned monitors and control devices
License Application Design Selection Feature Report: Waste Package Self Shielding Design Feature 13
International Nuclear Information System (INIS)
Tang, J.S.
2000-01-01
In the Viability Assessment (VA) reference design, handling of waste packages (WPs) in the emplacement drifts is performed remotely, and human access to the drifts is precluded when WPs are present. This report will investigate the feasibility of using a self-shielded WP design to reduce the radiation levels in the emplacement drifts to a point that, when coupled with ventilation, will create an acceptable environment for human access. This provides the benefit of allowing human entry to emplacement drifts to perform maintenance on ground support and instrumentation, and carry out performance confirmation activities. More direct human control of WP handling and emplacement operations would also be possible. However, these potential benefits must be weighed against the cost of implementation, and potential impacts on pre- and post-closure performance of the repository and WPs. The first section of this report will provide background information on previous investigations of the self-shielded WP design feature, summarize the objective and scope of this document, and provide quality assurance and software information. A shielding performance and cost study that includes several candidate shield materials will then be performed in the subsequent section to allow selection of two self-shielded WP design options for further evaluation. Finally, the remaining sections will evaluate the impacts of the two WP self-shielding options on the repository design, operations, safety, cost, and long-term performance of the WPs with respect to the VA reference design
International Nuclear Information System (INIS)
Coste-Delclaux, M.; Aggery, A.; Huot, N.
2005-01-01
APOLLO2 is a modular multigroup transport code developed by Cea in Saclay. Until last year, the self-shielding module could only treat one resonant isotope mixed with moderator isotopes. Consequently, the resonant mixture self-shielding treatment was an iterative one. Each resonant isotope of the mixture was treated separately, the other resonant isotopes of the mixture being then considered as moderator isotopes, that is to say non-resonant isotopes. This treatment could be iterated. Last year, we have developed a new method that consists in treating the resonant mixture as a unique entity. A main feature of APOLLO2 self-shielding module is that some implemented models are very general and therefore very powerful and versatile. We can give, as examples, the use of probability tables in order to describe the microscopic cross-section fluctuations or the TR slowing-down model that can deal with any resonance shape. The self-shielding treatment of a resonant mixture was developed essentially thanks to these two models. The calculations of a simplified Jules Horowitz reactor using a Monte-Carlo code (TRIPOLI4) as a reference and APOLLO2 in its standard and improved versions, show that, as far as the effective multiplication factor is concerned, the mixture treatment does not bring an improvement, because the new treatment suppresses compensation between the reaction rate discrepancies. The discrepancy of 300 pcm that appears with the reference calculation is in accordance with the technical specifications of the Jules Horowitz reactor
Self Shielding in Nuclear Fissile Assay Using LSDS
International Nuclear Information System (INIS)
Lee, Yong Deok; Park, Chang Je; Park, Geun Il; Song, Kee Chan
2012-01-01
The new technology for isotopic fissile material contents assay is under development at KAERI using lead slowing down spectrometer(LSDS). LSDS is very sensitive to distinguish fission signals from each fissile isotope in spent and recycled fuel. The accumulation of spent fuel is current big issue. The amount of spent fuels will reach the maximum storage capacity of the pools soon. Therefore, an interim storage must be searched and it should be optimized in design by applying accurate fissile content. When the storage has taken effect, all the nuclear materials must be also specified and verified for safety, economics and management. Generally, the spent fuel from PWR has unburned ∼1 % U235, produced ∼0.5 % plutonium from decay chain, ∼3 % fission products, ∼ 0.1 % minor actinides (MA) and uranium remainder. About 1.5 % fissile materials still exist in the spent fuel. Therefore, for reutilization of fissile materials in spent fuel at SFR, resource material is produced through pyro process. Fissile material contents in resource material must be analyzed before fabricating SFR fuel for reactor safety and economics. In assay of fissile content of spent fuel and recycled fuel, intense radiation background gives limitation on the direct analysis of fissile materials. However, LSDS is not influenced by such a radiation background in fissile assay. Based on the decided geometry setup, self shielding parameter was calculated at the fuel assay zone by introducing spent fuel or pyro produced nuclear material. When nuclear material is inserted into the assay area, the spent fuel assembly or pyro recycled fuel material perturbs the spatial distribution of the slowing down neutrons in lead and the prompt fast fission neutrons produced by fissile materials are also perturbed. The self shielding factor is interpreted as that how much of absorption is created inside the fuel area when it is in the lead. Self shielding effect provides a non-linear property in the isotopic
Space Station Validation of Advanced Radiation-Shielding Polymeric Materials, Phase II
National Aeronautics and Space Administration — In Subtopic X11.01, NASA has identified the need to develop advanced radiation-shielding materials and systems to protect humans from the hazards of space radiation...
Shield wall evaluation of hot cell facility for advanced spent fuel conditioning process
International Nuclear Information System (INIS)
Cho, I. J.; Kuk, D. H.; Ko, J. H.; Jung, W. M.; Yoo, G. S.; Lee, E. P.; Park, S. W.
2002-01-01
The future hot cell is located in the Irradiated Material Experiment Facility (IMEF) at the Korea Atomic Energy Research Institute (KAERI). It is β-γ type hot cell that was constructed on the base floor in IMEF building for irradiated material testing. And this hot cell will be used for carrying out the Advanced spent fuel Conditioning Process (ACP). The radiation shielding capability of hot cell should be sufficient to meet the radiation dose requirements in the related regulations. Because the radioactive sources of ACP are expected to be higher than radioactive sources of IMEF design criteria, the future hot cell in current status is unsatisfactory to hot test of ACP. So the shielding analysis of the future hot cell is performed to evaluate shielding ability of concrete shield wall. The shielding analysis included (a) identification of ACP source term; (b) photon source spectrum; (c) shielding analysis by QADS and MCNP-4C; and (d) enhancement of concrete shield wall. In this research, dose rates are obtained according to ACP source, geometry and hot cell shield wall thickness. And the evaluation and reinforcement thickness of the shield wall about future hot cell are concluded
Determination of self shielding factors and gamma attenuation effects for tree ring samples
International Nuclear Information System (INIS)
Dagistan Sahin; Kenan Uenlue
2012-01-01
Determination of tree ring chemistry using Neutron Activation Analysis (NAA) is part of an ongoing research between Penn State University (PSU) and Cornell University, The Malcolm and Carolyn Wiener Laboratory for Aegean and Near Eastern Dendrochronology. Tree-ring chemistry yields valuable data for environmental event signatures. These signatures are a complex function of elemental concentration. To be certain about concentration of signature elements, it is necessary to perform the measurements and corrections with the lowest error and maximum accuracy possible. Accurate and precise values of energy dependent neutron flux at dry irradiation tubes and detector efficiency for tree ring sample are calculated for Penn State Breazeale Reactor (PSBR). For the calculation of energy dependent and self shielding corrected neutron flux, detailed model of the TRIGA Mark III reactor at PSU with updated fuel compositions was prepared using the MCNP utility for reactor evolution (MURE) libraries. Dry irradiation tube, sample holder and sample were also included in the model. The thermal flux self-shielding correction factors due to the sample holder and sample for were calculated and verified with previously published values. The Geant-4 model of the gamma spectroscopy system, developed at Radiation Science and Engineering Center (RSEC), was improved and absolute detector efficiency for tree-ring samples was calculated. (author)
Shielding considerations for advanced space nuclear reactor systems
International Nuclear Information System (INIS)
Angelo, J.P. Jr.; Buden, D.
1982-01-01
To meet the anticipated future space power needs, the Los Alamos National Laboratory is developing components for a compact, 100 kW/sub e/-class heat pipe nuclear reactor. The reactor uses uranium dioxide (UO 2 ) as its fuel, and is designed to operate around 1500 k. Heat pipes are used to remove thermal energy from the core without the use of pumps or compressors. The reactor heat pipes transfer mal energy to thermoelectric conversion elements that are advanced versions of the converters used on the enormously successful Voyager missions to the outer planets. Advanced versions of this heat pipe reactor could also be used to provide megawatt-level power plants. The paper reviews the status of this advanced heat pipe reactor and explores the radiation environments and shielding requirements for representative manned and unmanned applications
Importance of self-shielding for improving sensitivity coefficients in light water nuclear reactors
International Nuclear Information System (INIS)
Foad, Basma; Takeda, Toshikazu
2014-01-01
Highlights: • A new method has been developed for calculating sensitivity coefficients. • This method is based on the use of infinite dilution cross-sections instead of effective cross-sections. • The change of self-shielding factor due to cross-section perturbation has been considered. • SRAC and SAINT codes are used for calculating improved sensitivities, while MCNP code has been used for verification. - Abstract: In order to perform sensitivity analyzes in light water reactors where self-shielding effect becomes important, a new method has been developed for calculating sensitivity coefficient of core characteristics relative to the infinite dilution cross-sections instead of the effective cross-sections. This method considers the change of the self-shielding factor due to cross-section perturbation for different nuclides and reactions. SRAC and SAINT codes are used to calculate the improved sensitivity; while the accuracy of the present method has been verified by MCNP code and good agreement has been found
DEFF Research Database (Denmark)
Ruud, Kenneth; Helgaker, Trygve; Kobayashi, Rika
1994-01-01
to corresponding individual gauges for localized orbitals (IGLO) results. The London results show better basis set convergence than IGLO, especially for heavier atoms. It is shown that the choice of active space is crucial for determination of accurate nuclear shielding constants.......Nuclear shielding calculations are presented for multiconfigurational self-consistent field wave functions using London atomic orbitals (gauge invariant atomic orbitals). Calculations of nuclear shieldings for eight molecules (H2O, H2S, CH4, N2, CO, HF, F2, and SO2) are presented and compared...
International Nuclear Information System (INIS)
Zou Jun; He Zhaozhong; Zeng Qin; Qiu Yuefeng; Wang Minghuang
2010-01-01
A multigroup library HENDL2.1/SS (Hybrid Evaluated Nuclear Data Library/Self-Shielding) based on ENDF/B-VII.0 evaluate data has been generated using Bondarenko and flux calculator method for the correction of self-shielding effect of neutronics analyses. To validate the reliability of the multigroup library HENDL2.1/SS, transport calculations for fusion-fission hybrid system FDS-I were performed in this paper. It was verified that the calculations with the HENDL2.1/SS gave almost the same results with MCNP calculations and were better than calculations with the HENDL2.0/MG which is another multigroup library without self-shielding correction. The test results also showed that neglecting resonance self-shielding caused underestimation of the K eff , neutron fluxes and waste transmutation ratios in the multigroup calculations of FDS-I.
RZ calculations for self shielded multigroup cross sections
Energy Technology Data Exchange (ETDEWEB)
Li, M.; Sanchez, R.; Zmijarevic, I.; Stankovski, Z. [Commissariat a l' Energie Atomique CEA, Direction de l' Energie Nucleaire, DEN/DM2S/SERMA/LENR, 91191 Gif-sur-Yvette Cedex (France)
2006-07-01
A collision probability method has been implemented for RZ geometries. The method accounts for white albedo, specular and translation boundary condition on the top and bottom surfaces of the geometry and for a white albedo condition on the outer radial surface. We have applied the RZ CP method to the calculation of multigroup self shielded cross sections for Gadolinia absorbers in BWRs. (authors)
RZ calculations for self shielded multigroup cross sections
International Nuclear Information System (INIS)
Li, M.; Sanchez, R.; Zmijarevic, I.; Stankovski, Z.
2006-01-01
A collision probability method has been implemented for RZ geometries. The method accounts for white albedo, specular and translation boundary condition on the top and bottom surfaces of the geometry and for a white albedo condition on the outer radial surface. We have applied the RZ CP method to the calculation of multigroup self shielded cross sections for Gadolinia absorbers in BWRs. (authors)
Unresolved resonance self shielding calculation: causes and importance of discrepancies
International Nuclear Information System (INIS)
Ribon, P.; Tellier, H.
1986-01-01
To compute the self shielding coefficient, it is necessary to know the point-wise cross-sections. In the unresolved resonance region, the parameters of each level are not known; only the average parameters. Therefore the authors simulate the point-wise cross-section by random sampling of the energy levels and resonance parameters with respect to the Wigner law and the x 2 distributions, and by computing the cross-section in the same way as in the resolved regions. The result of this statistical calculation obviously depends on the initial parameters but also on the method of sampling, on the formalism which is used to compute the cross-section or on the weighting neutron flux. In this paper, the authors survey the main phenomena which can induce discrepancies in self shielding computations. Results are given for typical dilutions which occur in nuclear reactors
International Nuclear Information System (INIS)
Patino, N.E.; Abbate, M.J.; Sbaffoni, M.M.
1990-01-01
The procedures employed in the treatment of the resonance shielding effect have been identified as one of the causes of the large discrepancies found in the neutronic calculation of high conversion light water reactors (HCLWRs), indicating the need for a revision of the self-shielding procedures employed. In this work some well known techniques applied in HCLWR self-shielding calculations are evaluated; the study involves the comparison of methods for the generation of group constants, the analysis of the impact of considering some isotopes as infinitely diluted and the evaluation of the usual approximations utilized for the treatment of heterogeneities
Calculation of the electron trajectory for 200 kV self-shielded electron accelerator
International Nuclear Information System (INIS)
Wang Shuiqing
2000-01-01
In order to calculate the electron trajectory of 200 kV self-shielded electron accelerator, the electric field is calculated with a TRAJ program. In this program, following electron track mash points one by one, the electron beam trajectories are calculated. Knowing the effect of grid voltage on electron optics and gaining grid voltage focusing effect in the various energy grades, the authors have gained scientific basis for adjusting grid voltage, and also accumulated a wealth of experience for designing self-shielded electron accelerator or electron curtain in future
International Nuclear Information System (INIS)
Pantazi, D.; Mateescu, S.; Stanciu, M.
2003-01-01
One of the technical measures of protection against ionizing radiations is the radiation shielding. The process of implementing modern and efficient methods of evaluating the radiation shielding implies advanced calculation methods. That means using from simpler 1-D or 2-D computing codes such as MicroShield or QAD up to systems of codes such as SCALE (containing several independent modules) or the Monte Carlo multipurpose and many particles, MCNP, transport code. The main objective of this work is to present the Monte Carlo based evaluation of the dose rates from the CANDU type spent fuel all along the path of its handling up to intermediate storage. These values will be then compared with the values obtained from calculations with different computing programs. To obtain this objective two problems were approached: - establishing geometrical models according to the definition used by MCNP code so that the characteristics of CANDU type nuclear fuel are taking into account; - checking the validity of the proposed models by comparing the MCNP results with those obtained with other computing codes specific for shielding evaluation and radiation dose calculation
International Nuclear Information System (INIS)
Nodaka, M.; Iida, T.; Taniuchi, H.; Yosimura, K.; Nagahama, H.
1993-01-01
From among the neutron shielding materials of the 'kobesh' series developed by Kobe Steel, Ltd. for transport and storage packagings, silicon rubber base type material has been tested for several items with a view to practical application and official authorization, and in order to determine its adaptability to actual vessels. Silicon rubber base type 'kobesh SR-T01' is a material in which, from among the silicone rubber based neutron shielding materials, the hydrogen content is highest and the boron content is most optimized. Its neutron shielding capability has been already described in the previous report (Taniuchi, 1986). The following tests were carried out to determine suitability for practical application; 1) Long-term thermal stability test 2) Pouring test on an actual-scale model 3) Fire test The experimental results showed that the silicone rubber based neutron shielding material has good neutron shielding capability and high long-term fire resistance, and that it can be applied to the advanced transport packaging. (author)
Unresolved resonance self shielding calculation: causes and importance of discrepancies
International Nuclear Information System (INIS)
Ribon, P.; Tellier, H.
1986-09-01
To compute the self shielding coefficient, it is necessary to know the point-wise cross-sections. In the unresolved resonance region, we do not know the parameters of each level but only the average parameters. Therefore we simulate the point-wise cross-section by random sampling of the energy levels and resonance parameters with respect to the Wigner law and the X 2 distributions, and by computing the cross-section in the same way as in the resolved regions. The result of this statistical calculation obviously depends on the initial parameters but also on the method of sampling, on the formalism which is used to compute the cross-section or on the weighting neutron flux. In this paper, we will survey the main phenomena which can induce discrepancies in self shielding computations. Results are given for typical dilutions which occur in nuclear reactors. 8 refs
Validation of calculated self-shielding factors for Rh foils
Jaćimović, R.; Trkov, A.; Žerovnik, G.; Snoj, L.; Schillebeeckx, P.
2010-10-01
Rhodium foils of about 5 mm diameter were obtained from IRMM. One foil had thickness of 0.006 mm and three were 0.112 mm thick. They were irradiated in the pneumatic transfer system and in the carousel facility of the TRIGA reactor at the Jožef Stefan Institute. The foils were irradiated bare and enclosed in small cadmium boxes (about 2 g weight) of 1 mm thickness to minimise the perturbation of the local neutron flux. They were co-irradiated with 5 mm diameter and 0.2 mm thick Al-Au (0.1%) alloy monitor foils. The resonance self-shielding corrections for the 0.006 and 0.112 mm thick samples were calculated by the Monte Carlo simulation and amount to about 10% and 60%, respectively. The consistency of measurements confirmed the validity of self-shielding factors. Trial estimates of Q0 and k0 factors for the 555.8 keV gamma line of 104Rh were made and amount to 6.65±0.18 and (6.61±0.12)×10 -2, respectively.
The self shielding module of Apollo.II; Module d`autoprotection du code Apollo.II
Energy Technology Data Exchange (ETDEWEB)
Sanchez, R.
1994-06-01
This note discusses the methods used in the APOLLO.II code for the calculation of self shielded multigroup cross sections. Basically, the calculation consists in characterizing a heterogenous medium with a single parameter: the background cross section, which is in then used to interpolate reaction rates from pre tabulated values. Very fine multigroup slowing down calculations in homogenous media are used to generate these tables, which contain absorption, diffusion and production reaction rates per group, resonant isotope, temperature and background cross section. Multigroup self shielded cross sections are determined from an equivalence that preserves absorption rates at a slowing down problem with given sources. This article gives a detailed description of the PIC and ``dilution matrix`` formalisms that are used in the homogenization step, as well as the utilization of Bell macro-groups and the different quadrature formulas that may be used in the calculations. Self shielding techniques for isotopic resonant mixtures are also discussed. (author). 2 refs., 193 figs., 2 tabs.
International Nuclear Information System (INIS)
Nasrabadi, M.N.; Jalali, M.; Mohammadi, A.
2007-01-01
In this work thermal neutron self-shielding in aqueous bulk samples containing neutron absorbing materials is studied using bulk sample prompt gamma neutron activation analysis (BSPGNAA) with the MCNP code. The code was used to perform three dimensional simulations of a neutron source, neutron detector and sample of various material compositions. The MCNP model was validated against experimental measurements of the neutron flux performed using a BF 3 detector. Simulations were performed to predict thermal neutron self-shielding in aqueous bulk samples containing neutron absorbing solutes. In practice, the MCNP calculations are combined with experimental measurements of the relative thermal neutron flux over the sample's surface, with respect to a reference water sample, to derive the thermal neutron self-shielding within the sample. The proposed methodology can be used for the determination of the elemental concentration of unknown aqueous samples by BSPGNAA where knowledge of the average thermal neutron flux within the sample volume is required
An ''exact'' treatment of self-shielding and covers in neutron spectra determinations
International Nuclear Information System (INIS)
Griffin, P.J.; Kelly, J.G.
1995-01-01
Most neutron spectrum determination methodologies ignore self-shielding effects in dosimetry foils and treat covers with an exponential attenuation model. This work provides a quantitative analysis of the approximations in this approach. It also provides a methodology for improving the fidelity of the treatment of the dosimetry sensor response to a level consistent with the user's spectrum characterization approach. A library of correction functions for the energy-dependent sensor response has been compiled that addresses dosimetry foils/configurations in use at the Sandia National Laboratories Radiation Metrology Laboratory
International Nuclear Information System (INIS)
Cullen, D.E.
1978-01-01
Bonderenko self-shielded cross sections and multiband parameters from the Lawrence Livermore Laboratory Evaluated-Nuclear-Data Library (ENDL) as of July 4, 1978 are presented. These data include total, elastic, capture, and fission cross sections in the TART 175 group structure. Multiband parameters are listed. Bonderenko self-shielded cross section and the multiband parameters are presented on microfiche
CREST : a computer program for the calculation of composition dependent self-shielded cross-sections
International Nuclear Information System (INIS)
Kapil, S.K.
1977-01-01
A computer program CREST for the calculation of the composition and temperature dependent self-shielded cross-sections using the shielding factor approach has been described. The code includes the editing and formation of the data library, calculation of the effective shielding factors and cross-sections, a fundamental mode calculation to generate the neutron spectrum for the system which is further used to calculate the effective elastic removal cross-sections. Studies to explore the sensitivity of reactor parameters to changes in group cross-sections can also be carried out by using the facility available in the code to temporarily change the desired constants. The final self-shielded and transport corrected group cross-sections can be dumped on cards or magnetic tape in a suitable form for their direct use in a transport or diffusion theory code for detailed reactor calculations. The program is written in FORTRAN and can be accommodated in a computer with 32 K work memory. The input preparation details, sample problem and the listing of the program are given. (author)
Success and prospects for low energy, self-shielded electron beam accelerators
International Nuclear Information System (INIS)
Laeuppi, U.V.
1988-01-01
The advantages of self-shielded, low energy, electron beam accelerators for electron beam processing are described. Applications of these accelerators for cross-linking plastic films, drying of coated materials and printing inks and for curing processes are discussed. (U.K.)
AUTOSECOL: an automatic calculation of the self-shielding of heavy isotope resonances
International Nuclear Information System (INIS)
Grandotto-Biettoli, Marc.
The formalism is based on separating both types of resonance effects: local energy effects creating a fine structure in the flux, and bulk effects resulting in a slow variation in the flux. Effective reaction rates are defined that, used as tables in a multigroup calculation of cells with a large pitch in regard to resonance widths, allow an exact account of the dependence of the effective integral upon fast variations in the flux. These tables are used to introduce this phenomenon of resonance self-shielding in the multigroup Apollo program for solving the neutron transport equation, they are derived from nuclear data with using some parameters relating to the physical state of the resonant isotope inside the fuel medium. The AUTOSECOL system provides a library of effective reaction rates for taking account of the resonance self-shielding effect on the neutron flux in nuclear reactor cells. Its versatility in regard to the methods previously used for solving the same problem allows a rapid testing of the consequences of considering the self-shielding effect of new isotope resonances, a following up of the evolution in nuclear data evaluation, and rapidly studying the interest lying in new data. Results obtained with AUTOSECOL are compared with those obtained when using the SECOL code for computing the effective reaction rates of 235 U, 239 Pu, 107 Ag, 109 Ag, and 241 Pu [fr
Testing of the PELSHIE shielding code using Benchmark problems and other special shielding models
International Nuclear Information System (INIS)
Language, A.E.; Sartori, D.E.; De Beer, G.P.
1981-08-01
The PELSHIE shielding code for gamma rays from point and extended sources was written in 1971 and a revised version was published in October 1979. At Pelindaba the program is used extensively due to its flexibility and ease of use for a wide range of problems. The testing of PELSHIE results with the results of a range of models and so-called Benchmark problems is desirable to determine possible weaknesses in PELSHIE. Benchmark problems, experimental data, and shielding models, some of which were resolved by the discrete-ordinates method with the ANISN and DOT 3.5 codes, were used for the efficiency test. The description of the models followed the pattern of a classical shielding problem. After the intercomparison with six different models, the usefulness of the PELSHIE code was quantitatively determined [af
Radev, Dimitar; Lokshina, Izabella
2010-11-01
The paper examines self-similar (or fractal) properties of real communication network traffic data over a wide range of time scales. These self-similar properties are very different from the properties of traditional models based on Poisson and Markov-modulated Poisson processes. Advanced fractal models of sequentional generators and fixed-length sequence generators, and efficient algorithms that are used to simulate self-similar behavior of IP network traffic data are developed and applied. Numerical examples are provided; and simulation results are obtained and analyzed.
Depleted uranium hexafluoride: The source material for advanced shielding systems
Energy Technology Data Exchange (ETDEWEB)
Quapp, W.J.; Lessing, P.A. [Idaho National Engineering Lab., Idaho Falls, ID (United States); Cooley, C.R. [Department of Technology, Germantown, MD (United States)
1997-02-01
The U.S. Department of Energy (DOE) has a management challenge and financial liability problem in the form of 50,000 cylinders containing 555,000 metric tons of depleted uranium hexafluoride (UF{sub 6}) that are stored at the gaseous diffusion plants. DOE is evaluating several options for the disposition of this UF{sub 6}, including continued storage, disposal, and recycle into a product. Based on studies conducted to date, the most feasible recycle option for the depleted uranium is shielding in low-level waste, spent nuclear fuel, or vitrified high-level waste containers. Estimates for the cost of disposal, using existing technologies, range between $3.8 and $11.3 billion depending on factors such as the disposal site and the applicability of the Resource Conservation and Recovery Act (RCRA). Advanced technologies can reduce these costs, but UF{sub 6} disposal still represents large future costs. This paper describes an application for depleted uranium in which depleted uranium hexafluoride is converted into an oxide and then into a heavy aggregate. The heavy uranium aggregate is combined with conventional concrete materials to form an ultra high density concrete, DUCRETE, weighing more than 400 lb/ft{sup 3}. DUCRETE can be used as shielding in spent nuclear fuel/high-level waste casks at a cost comparable to the lower of the disposal cost estimates. Consequently, the case can be made that DUCRETE shielded casks are an alternative to disposal. In this case, a beneficial long term solution is attained for much less than the combined cost of independently providing shielded casks and disposing of the depleted uranium. Furthermore, if disposal is avoided, the political problems associated with selection of a disposal location are also avoided. Other studies have also shown cost benefits for low level waste shielded disposal containers.
Space nuclear reactor shields for manned and unmanned applications
International Nuclear Information System (INIS)
McKissock, B.I.; Bloomfield, H.S.
1990-01-01
Missions which use nuclear reactor power systems require radiation shielding of payload and/or crew areas to predetermined dose rates. Since shielding can become a significant fraction of the total mass of the system, it is of interest to show the effect of various parameters on shield thickness and mass for manned and unmanned applications. Algorithms were developed to give the thicknesses needed if reactor thermal power, separation distances and dose rates are given as input. The thickness algorithms were combined with models for four different shield geometries to allow tradeoff studies of shield volume and mass for a variety of manned and unmanned missions. The shield design tradeoffs presented in this study include the effects of: higher allowable dose rates; radiation hardened electronics; shorter crew exposure times; shield geometry; distance of the payload and/or crew from the reactor; and changes in the size of the shielded area. Specific NASA missions that were considered in this study include unmanned outer planetary exploration, manned advanced/evolutionary space station and advanced manned lunar base. (author)
Space nuclear reactor shields for manned and unmanned applications
International Nuclear Information System (INIS)
Mckissock, B.I.; Bloomfield, H.S.
1989-01-01
Missions which use nuclear reactor power systems require radiation shielding of payload and/or crew areas to predetermined dose rates. Since shielding can become a significant fraction of the total mass of the system, it is of interest to show the effect of various parameters on shield thickness and mass for manned and unmanned applications. Algorithms were developed to give the thicknesses needed if reactor thermal power, separation distances, and dose rates are given as input. The thickness algorithms were combined with models for four different shield geometries to allow tradeoff studies of shield volume and mass for a variety of manned and unmanned missions. Shield design tradeoffs presented in this study include the effects of: higher allowable dose rates; radiation hardened electronics; shorter crew exposure times; shield geometry; distance of the payload and/or crew from the reactor; and changes in the size of the shielded area. Specific NASA missions that were considered in this study include unmanned outer planetary exploration, manned advanced/evolutionary space station, and advanced manned lunar base
International Nuclear Information System (INIS)
Kaul, D.C.
1982-01-01
Throughout the last two decades many efforts have been made to estimate the effect of body self-shielding on organ doses from externally incident neutrons and gamma rays. These began with the use of simple geometry phantoms and have culminated in the use of detailed anthropomorphic phantoms. In a recent effort, adjoint Monte Carlo analysis techniques have been used to determine dose and dose equivalent to the active marrow as a function of energy and angle of neutron fluence externally incident on an anthropomorphic phantom. When combined with fluences from actual nuclear devices, these dose-to-fluence factors result in marrow dose values that demonstrate great sensitivity to variations in device type, range, and body orientation. Under a state-of-the-art radiation transport analysis demonstration program for the Japanese cities, sponsored by the Defense Nuclear Agency at the request of the National Council on Radiation Protection and Measurements, the marrow dose study referred to above is being repeated to obtain spectral distributions within the marrow for externally incident neutrons and gamma rays of arbitrary energy and angle. This is intended to allow radiobiologists and epidemiologists to select and to modify numbers of merit for correlation with health effects and to permit a greater understanding of the relationship between human and laboratory subject dosimetry
Guide to beamline radiation shielding design at the Advanced Photon Source
International Nuclear Information System (INIS)
Ipe, N.; Haeffner, D.R.; Alp, E.E.; Davey, S.C.; Dejus, R.J.; Hahn, U.; Lai, B.; Randall, K.J.; Shu, D.
1993-11-01
This document is concerned with the general requirements for radiation shielding common to most Advanced Photon Source (APS) users. These include shielding specifications for hutches, transport, stops, and shutters for both white and monochromatic beams. For brevity, only the results of calculations are given in most cases. So-called open-quotes special situationsclose quotes are not covered. These include beamlines with white beam mirrors for low-pass energy filters (open-quotes pink beamsclose quotes), extremely wide band-pass monochromators (multilayers), or novel insertion devices. These topics are dependent on beamline layout and, as such, are not easily generalized. Also, many examples are given for open-quotes typicalclose quotes hutches or other beamline components. If a user has components that differ greatly from those described, particular care should be taken in following these guidelines. Users with questions on specific special situations should address them to the APS User Technical Interface. Also, this document does not cover specifics on hutch, transport, shutter, and stop designs. Issues such as how to join hutch panels, floor-wall interfaces, cable feed-throughs, and how to integrate shielding into transport are covered in the APS Beamline Standard Components Handbook. It is a open-quotes living documentclose quotes and as such reflects the improvements in component design that are ongoing. This document has the following content. First, the design criteria will be given. This includes descriptions of some of the pertinent DOE regulations and policies, as well as brief discussions of abnormal situations, interlocks, local shielding, and storage ring parameters. Then, the various sources of radiation on the experimental floor are discussed, and the methods used to calculate the shielding are explained (along with some sample calculations). Finally, the shielding recommendations for different situations are given and discussed
Multifunctional Shielding and Self-Healing HybridSil Smart Composites for Space, Phase II
National Aeronautics and Space Administration — NanoSonic has developed revolutionary multifunctional, super lightweight, self-healing and radiation shielding carbon fiber reinforced polymer (CFRP) composites as a...
Modelling and Optimization of Four-Segment Shielding Coils of Current Transformers.
Gao, Yucheng; Zhao, Wei; Wang, Qing; Qu, Kaifeng; Li, He; Shao, Haiming; Huang, Songling
2017-05-26
Applying shielding coils is a practical way to protect current transformers (CTs) for large-capacity generators from the intensive magnetic interference produced by adjacent bus-bars. The aim of this study is to build a simple analytical model for the shielding coils, from which the optimization of the shielding coils can be calculated effectively. Based on an existing stray flux model, a new analytical model for the leakage flux of partial coils is presented, and finite element method-based simulations are carried out to develop empirical equations for the core-pickup factors of the models. Using the flux models, a model of the common four-segment shielding coils is derived. Furthermore, a theoretical analysis is carried out on the optimal performance of the four-segment shielding coils in a typical six-bus-bars scenario. It turns out that the "all parallel" shielding coils with a 45° starting position have the best shielding performance, whereas the "separated loop" shielding coils with a 0° starting position feature the lowest heating value. Physical experiments were performed, which verified all the models and the conclusions proposed in the paper. In addition, for shielding coils with other than the four-segment configuration, the analysis process will generally be the same.
Neutron radiation shielding properties of polymer incorporated self compacting concrete mixes.
Malkapur, Santhosh M; Divakar, L; Narasimhan, Mattur C; Karkera, Narayana B; Goverdhan, P; Sathian, V; Prasad, N K
2017-07-01
In this work, the neutron radiation shielding characteristics of a class of novel polymer-incorporated self-compacting concrete (PISCC) mixes are evaluated. Pulverized high density polyethylene (HDPE) material was used, at three different reference volumes, as a partial replacement to river sand in conventional concrete mixes. By such partial replacement of sand with polymer, additional hydrogen contents are incorporated in these concrete mixes and their effect on the neutron radiation shielding properties are studied. It has been observed from the initial set of experiments that there is a definite trend of reductions in the neutron flux and dose transmission factor values in these PISCC mixes vis-à-vis ordinary concrete mix. Also, the fact that quite similar enhanced shielding results are recorded even when reprocessed HDPE material is used in lieu of the virgin HDPE attracts further attention. Copyright © 2017 Elsevier Ltd. All rights reserved.
Design of a control system for self-shielded irradiators with remote access capability
International Nuclear Information System (INIS)
Iyengar, R.D.; Verma, P.B.; Prasad, V.V.S.S.; George, Jain R.; Das, Tripti; Deshmukh, D.K.
2001-01-01
With self-shielded irradiators like Gamma chambers, and Blood irradiators are being sold by BRIT to customers both within and outside the country, it has become necessary to improve the quality of service without increasing the overheads. The recent advances in the field of communications and information technology can be exploited for improving the quality of service to the customers. A state of the art control system with remote accessibility has been designed for these irradiators enhancing their performance. This will provide an easy access to these units wherever they might be located, through the Internet. With this technology it will now be possible to attend to the needs of the customers, as regards fault rectification, error debugging, system software update, performance testing, data acquisition etc. This will not only reduce the downtime of these irradiators but also reduce the overheads. (author)
International Nuclear Information System (INIS)
Stimpson, Shane G.; Liu, Yuxuan; Collins, Benjamin S.; Clarno, Kevin T.
2017-01-01
An essential component of the neutron transport solver is the resonance self-shielding calculation used to determine equivalence cross sections. The neutron transport code, MPACT, is currently using the subgroup self-shielding method, in which the method of characteristics (MOC) is used to solve purely absorbing fixed-source problems. Recent efforts incorporating multigroup kernels to the MOC solvers in MPACT have reduced runtime by roughly 2×. Applying the same concepts for self-shielding and developing a novel lumped parameter approach to MOC, substantial improvements have also been made to the self-shielding computational efficiency without sacrificing any accuracy. These new multigroup and lumped parameter capabilities have been demonstrated on two test cases: (1) a single lattice with quarter symmetry known as VERA (Virtual Environment for Reactor Applications) Progression Problem 2a and (2) a two-dimensional quarter-core slice known as Problem 5a-2D. From these cases, self-shielding computational time was reduced by roughly 3–4×, with a corresponding 15–20% increase in overall memory burden. An azimuthal angle sensitivity study also shows that only half as many angles are needed, yielding an additional speedup of 2×. In total, the improvements yield roughly a 7–8× speedup. Furthermore given these performance benefits, these approaches have been adopted as the default in MPACT.
Directory of Open Access Journals (Sweden)
Shane Stimpson
2017-09-01
Full Text Available An essential component of the neutron transport solver is the resonance self-shielding calculation used to determine equivalence cross sections. The neutron transport code, MPACT, is currently using the subgroup self-shielding method, in which the method of characteristics (MOC is used to solve purely absorbing fixed-source problems. Recent efforts incorporating multigroup kernels to the MOC solvers in MPACT have reduced runtime by roughly 2×. Applying the same concepts for self-shielding and developing a novel lumped parameter approach to MOC, substantial improvements have also been made to the self-shielding computational efficiency without sacrificing any accuracy. These new multigroup and lumped parameter capabilities have been demonstrated on two test cases: (1 a single lattice with quarter symmetry known as VERA (Virtual Environment for Reactor Applications Progression Problem 2a and (2 a two-dimensional quarter-core slice known as Problem 5a-2D. From these cases, self-shielding computational time was reduced by roughly 3–4×, with a corresponding 15–20% increase in overall memory burden. An azimuthal angle sensitivity study also shows that only half as many angles are needed, yielding an additional speedup of 2×. In total, the improvements yield roughly a 7–8× speedup. Given these performance benefits, these approaches have been adopted as the default in MPACT.
Ayaki, Masahiko; Hattori, Atsuhiko; Maruyama, Yusuke; Nakano, Masaki; Yoshimura, Michitaka; Kitazawa, Momoko; Negishi, Kazuno; Tsubota, Kazuo
2016-01-01
We investigated sleep quality and melatonin in 12 adults who wore blue-light shield or control eyewear 2 hours before sleep while using a self-luminous portable device, and assessed visual quality for the two eyewear types. Overnight melatonin secretion was significantly higher after using the blue-light shield (P light shield (P light shield as providing acceptable visual quality.
Tools and applications for core design and shielding in fast reactors
International Nuclear Information System (INIS)
Rachamin, Reuven
2013-01-01
Outline: • Modeling of SFR cores using the Serpent-DYN3D code sequence; • Core shielding assessment for the design of FASTEF-MYRRHA; • Neutron shielding studies on an advanced Molten Salt Fast Reactor (MSFR) design
International Nuclear Information System (INIS)
Li, J.; Nuenighoff; Pohl, C.; Allelein, H.J.
2010-01-01
The gas-cooled, high temperature reactor (HTR) represents a valuable option for the future development of nuclear technology, because of its excellent safety features. One main safety feature is the negative temperature coefficient which is due to the Doppler broadening of the (n,y) resonance absorption cross section. A second important effect is the spatial self-shielding due to the double heterogeneous geometry of a pebble bed reactor. At FZ-Juelich two reactor analysis codes have been developed: VSOP for core design and MGT for transient analysis. Currently an update of the nuclear cross section libraries to ENDF/B-VII.0 of both codes takes place. In order to take the temperature dependency as well as the spatial self-shielding into account the absorption cross sections σ (n,y) for the resonance absorbers like 232 Th and 238 U have to be provided as function of incident neutron energy, temperature and nuclide concentration. There are two reasons for choosing the Monte-Carlo approach to calculate group wise cross sections. First, the former applied ZUT-DGL code to generate the resonance cross section tables for MGT is so far not able to handle the new resonance description based on Reich-Moore instead of Single-level Breit-Wigner. Second, the rising interest in PuO 2 fuel motivated an investigation on the generation of group wise cross sections describing thermal resonances of 240 Pu and 242 Pu. (orig.)
International Nuclear Information System (INIS)
Abe, Alfredo Y.; Santos, Adimir dos
1995-01-01
The present work summarizes the verification of the treatment of self-shielding based on Bondarenko method in HAMMER-TECHNION cell code for the Pu O 2 -U O 2 critical system using JENDL-3 nuclear data library. The results obtained are in excellent agreement with the original treatment of self-shielding employed by HAMMER-TECHNION cell code. (author). 9 refs, 1 fig, 9 tabs
A conceptual gamma shield design using the DRP model computation
Energy Technology Data Exchange (ETDEWEB)
Ahmad, E E [Reactor Department, Nuclear Research Center, Atomic Energy Authority, Cairo (Egypt); Rahman, F A [National Center of Nuclear Safety and Radiation Control, Atomic Energy Authority, Cairo (Egypt)
1997-12-31
The purpose of this investigation is to assess basic areas of concern in the development of reactor shielding conceptual design calculations. A spherical shield model composed of low carbon steel and lead have been constructed to surround a Co-60 gamma point source. two alternative configurations have been considered in the model computation. The numerical calculations have been performed using both the ANISN code and DRP model computation together with the DLC 75-Bugle 80 data library. A resume of results for deep penetration in different shield materials with different packing densities is presented and analysed. The results showed that the gamma fluxes attenuation is increased with increasing distribution the packing density of the shield material which reflects its importance of considering it as a safety parameter in shielding design. 3 figs.
International Nuclear Information System (INIS)
Noorddin Ibrahim; Rosnie Akang
2009-01-01
Full text: One of the major problems encountered during the irradiation of large inhomogeneous samples in performing activation analysis using neutron is the perturbation of the neutron field due to absorption and scattering of neutron within the sample as well as along the neutron guide in the case of prompt gamma activation analysis. The magnitude of this perturbation shown by self-shielding coefficient and flux depression depend on several factors including the average neutron energy, the size and shape of the sample, as well as the macroscopic absorption cross section of the sample. In this study, we use Monte Carlo N-Particle codes to simulate the variation of neutron self-shielding coefficient and thermal flux depression factor as a function of the macroscopic thermal absorption cross section. The simulation works was carried out using the high performance computing facility available at UTM while the experimental work was performed at the tangential beam port of Reactor TRIGA PUSPATI, Malaysia Nuclear Agency. The neutron flux measured along the beam port is found to be in good agreement with the simulated data. Our simulation results also reveal that total flux perturbation factor decreases as the value of absorption increases. This factor is close to unity for low absorbing sample and tends towards zero for strong absorber. In addition, sample with long mean chord length produces smaller flux perturbation than the shorter mean chord length. When comparing both the graphs of self-shielding factor and total disturbance, we can conclude that the total disturbance of the thermal neutron flux on the large samples is dominated by the self-shielding effect. (Author)
Numerical and Analytical Model of an Electrodynamic Dust Shield for Solar Panels on Mars
Calle, C. I.; Linell, B.; Chen, A.; Meyer, J.; Clements, S.; Mazumder, M. K.
2006-01-01
Masuda and collaborators at the University of Tokyo developed a method to confine and transport particles called the electric curtain in which a series of parallel electrodes connected to an AC source generates a traveling wave that acts as a contactless conveyor. The curtain electrodes can be excited by a single-phase or a multi-phase AC voltage. A multi-phase curtain produces a non-uniform traveling wave that provides controlled transport of those particles [1-6]. Multi-phase electric curtains from two to six phases have been developed and studied by several research groups [7-9]. We have developed an Electrodynamic Dust Shield prototype using threephase AC voltage electrodes to remove dust from surfaces. The purpose of the modeling work presented here is to research and to better understand the physics governing the electrodynamic shield, as well as to advance and to support the experimental dust shield research.
Situations of potential exposure in self-shielding electron accelerators
International Nuclear Information System (INIS)
Rios, D.A.S.; Rios, P.B.; Sordi, G.M.A.A.; Carneiro, J.C.G.G.
2017-01-01
The study discusses situations in the industrial environment that may lead to potential exposure of Occupationally Exposed Individuals and Public Individuals in self-shielding electron accelerators. Although these exposure situations are unlikely, simulation exercises can lead to improvements in the operating procedure as well as suggest changes in production line design in order to increase radiation protection at work. These studies can also be used in training and demonstrate a solid application of the ALARA principle in the daily activities of radiative installations
CO Self-Shielding as a Mechanism to Make 16O-Enriched Solids in the Solar Nebula
Directory of Open Access Journals (Sweden)
Joseph A. Nuth, III
2014-05-01
Full Text Available Photochemical self-shielding of CO has been proposed as a mechanism to produce solids observed in the modern, 16O-depleted solar system. This is distinct from the relatively 16O-enriched composition of the solar nebula, as demonstrated by the oxygen isotopic composition of the contemporary sun. While supporting the idea that self-shielding can produce local enhancements in 16O-depleted solids, we argue that complementary enhancements of 16O-enriched solids can also be produced via C16O-based, Fischer-Tropsch type (FTT catalytic processes that could produce much of the carbonaceous feedstock incorporated into accreting planetesimals. Local enhancements could explain observed 16O enrichment in calcium-aluminum-rich inclusions (CAIs, such as those from the meteorite, Isheyevo (CH/CHb, as well as in chondrules from the meteorite, Acfer 214 (CH3. CO self-shielding results in an overall increase in the 17O and 18O content of nebular solids only to the extent that there is a net loss of C16O from the solar nebula. In contrast, if C16O reacts in the nebula to produce organics and water then the net effect of the self-shielding process will be negligible for the average oxygen isotopic content of nebular solids and other mechanisms must be sought to produce the observed dichotomy between oxygen in the Sun and that in meteorites and the terrestrial planets. This illustrates that the formation and metamorphism of rocks and organics need to be considered in tandem rather than as isolated reaction networks.
Advanced Neutron Source Reactor zoning, shielding, and radiological optimization guide
International Nuclear Information System (INIS)
Westbrook, J.L.; DeVore, J.R.
1995-08-01
In the design of major nuclear facilities, it is important to protect both humans and equipment excessive radiation dose. Past experience has shown that it is very effective to apply dose reduction principles early in the design of a nuclear facility both to specific design features and to the manner of operation of the facility, where they can aid in making the facility more efficient and cost-effective. Since the appropriate choice of radiological controls and practices varies according to the case, each area of the facility must be analyzed for its radiological impact, both by itself and in interactions with other areas. For the Advanced Neutron Source (ANS) project, a large relational database will be used to collect facility information by system and relate it to areas. The database will also hold the facility dose and shielding information as it is produced during the design process. This report details how the ANS zoning scheme was established and how the calculation of doses and shielding are to be done
A support shield for a powered support
Energy Technology Data Exchange (ETDEWEB)
Korczynski, P; Rojicek, P
1982-08-31
The subject of this invention is a support shield for a powered support. This shield resists creep of the coal from the longwall face, including an inclined longwall. It involves an arrangement wherein the distributor hinge is separated into upper and lower sections. The lower section holds a second hinge and the end of the rod of the pressure cylinder, one end of which is connected to the roof support. An advantage of the support is that compared to existing supports, it is self-advancing and holds stopes with coal which slopes in its formation or has inrushes. To a certain degree it prevents the stope space from ejecting fine pieces of rock from the longwall roof using an inter-timber support between the powered support and the stope. The support shield is moved by a simple system of levers which makes it possible, using a pressurized cylinder, to transmit a significant force to the coal stope. In this case, when the coal inrushes exceed the designed capabilities of the shield, a wooden extension piece is placed between the support and the face, through which the support pressure is applied.
REPOSITORY LAYOUT SUPPORTING DESIGN FEATURE NO.13 - WASTE PACKAGE SELF SHIELDING
International Nuclear Information System (INIS)
Owen, J.
1999-01-01
The objective of this analysis is to develop a repository layout, for Feature No. 13, that will accommodate self-shielding waste packages (WP) with an areal mass loading of 25 metric tons of uranium per acre (MTU/acre). The scope of this analysis includes determination of the number of emplacement drifts, amount of emplacement drift excavation required, and a preliminary layout for illustrative purposes
Energy Technology Data Exchange (ETDEWEB)
Yang, Myung Sic; Park, Ju Kyeong; Lee, Seung Hun; Kim, Yang Su; Lee, Sun Young; Cha, Seok Yong [Dept. of Radiation Oncology, Chonbuk National University Hospital, Jeonju (Korea, Republic of)
2014-12-15
To reduce the radiation dose to the thyroid that is affected to scattered radiation, the shield was used. And we evaluated the shielding effect for the thyroid during whole brain radiation therapy. To measure the dose of the thyroid, 300cGy were delivered to the phantom using a linear accelerator(Clinac iX VARIAN, USA.)in the way of the 6MV X-ray in bilateral. To measure the entrance surface dose of the thyroid, five glass dosimeters were placed in the 10th slice's surface of the phantom with a 1.5 cm interval. The average values were calculated by measured values in five times each, using bismuth shield, 0.5 mmPb shield, self-made 1.0 mmPb shield and unshield. In the same location, to measure the depth dose of the thyroid, five glass dosimeters were placed in the 10th slice by 2.5 cm depth of the phantom with a 1.5 cm interval. The average values were calculated by measured values in five times each, using bismuth shield, 0.5 mmPb shield, self-made 1.0 mmPb shield and unshield. Entrance surface dose of the thyroid were respectively 44.89 mGy at the unshield, 36.03 mGy at the bismuth shield, 31.03 mGy at the 0.5 mmPb shield and 23.21 mGy at a self-made 1.0 mmPb shield. In addition, the depth dose of the thyroid were respectively 36.10 mGy at the unshield, 34.52 mGy at the bismuth shield, 32.28 mGy at the 0.5 mmPb shield and 25.50 mGy at a self-made 1.0 mmPb shield. The thyroid was affected by the secondary scattering dose and leakage dose outside of the radiation field during whole brain radiation therapy. When using a shield in the thyroid, the depth dose of thyroid showed 11-30% reduction effect and the surface dose of thyroid showed 20-48% reduction effect. Therefore, by using the thyroid shield, it is considered to effectively protect the thyroid and can perform the treatment.
Self-shielding flex-circuit drift tube, drift tube assembly and method of making
Jones, David Alexander
2016-04-26
The present disclosure is directed to an ion mobility drift tube fabricated using flex-circuit technology in which every other drift electrode is on a different layer of the flex-circuit and each drift electrode partially overlaps the adjacent electrodes on the other layer. This results in a self-shielding effect where the drift electrodes themselves shield the interior of the drift tube from unwanted electro-magnetic noise. In addition, this drift tube can be manufactured with an integral flex-heater for temperature control. This design will significantly improve the noise immunity, size, weight, and power requirements of hand-held ion mobility systems such as those used for explosive detection.
International Nuclear Information System (INIS)
Nakagawa, Masayuki; Ishiguro, Yukio; Tokuno, Yukio.
1978-01-01
The self-shielding factors for elastic removal cross sections of light and medium weight nuclides were calculated for the parameter, σ 0 within the conventional concept of the group constant sets. The numerical study were performed for obtaining a simple and accurate method. The present results were compared with the exact values and the conventional ones, and shown to be remarkably improved. It became apparent that the anisotropy of the elastic scattering did not affect to the self-shielding factors though it did to the infinite dilution cross sections. With use of the present revised set, the neutron flux were calculated in an iron medium and in a prototype FBR and compared with those by the fine spectrum calculations and the conventional set. The present set showed the considerable improvement in the vicinity of the large resonance regions of sodium, iron and oxygen. (auth.)
Initial global 2-D shielding analysis for the Advanced Neutron Source core and reflector
Energy Technology Data Exchange (ETDEWEB)
Bucholz, J.A.
1995-08-01
This document describes the initial global 2-D shielding analyses for the Advanced Neutron Source (ANS) reactor, the D{sub 2}O reflector, the reflector vessel, and the first 200 mm of light water beyond the reflector vessel. Flux files generated here will later serve as source terms in subsequent shielding analyses. In addition to reporting fluxes and other data at key points of interest, a major objective of this report was to document how these analyses were performed, the phenomena that were included, and checks that were made to verify that these phenomena were properly modeled. In these shielding analyses, the fixed neutron source distribution in the core was based on the `lifetime-averaged` spatial power distribution. Secondary gamma production cross sections in the fuel were modified so as to account intrinsically for delayed fission gammas in the fuel as well as prompt fission gammas. In and near the fuel, this increased the low-energy gamma fluxes by 50 to 250%, but out near the reflector vessel, these same fluxes changed by only a few percent. Sensitivity studies with respect to mesh size were performed, and a new 2-D mesh distribution developed after some problems were discovered with respect to the use of numerous elongated mesh cells in the reflector. All of the shielding analyses were performed sing the ANSL-V 39n/44g coupled library with 25 thermal neutron groups in order to obtain a rigorous representation of the thermal neutron spectrum throughout the reflector. Because of upscatter in the heavy water, convergence was very slow. Ultimately, the fission cross section in the various materials had to be artificially modified in order to solve this fixed source problem as an eigenvalue problem and invoke the Vondy error-mode extrapolation technique which greatly accelerated convergence in the large 2-D RZ DORT analyses. While this was quite effective, 150 outer iterations (over energy) were still required.
Initial global 2-D shielding analysis for the Advanced Neutron Source core and reflector
International Nuclear Information System (INIS)
Bucholz, J.A.
1995-08-01
This document describes the initial global 2-D shielding analyses for the Advanced Neutron Source (ANS) reactor, the D 2 O reflector, the reflector vessel, and the first 200 mm of light water beyond the reflector vessel. Flux files generated here will later serve as source terms in subsequent shielding analyses. In addition to reporting fluxes and other data at key points of interest, a major objective of this report was to document how these analyses were performed, the phenomena that were included, and checks that were made to verify that these phenomena were properly modeled. In these shielding analyses, the fixed neutron source distribution in the core was based on the 'lifetime-averaged' spatial power distribution. Secondary gamma production cross sections in the fuel were modified so as to account intrinsically for delayed fission gammas in the fuel as well as prompt fission gammas. In and near the fuel, this increased the low-energy gamma fluxes by 50 to 250%, but out near the reflector vessel, these same fluxes changed by only a few percent. Sensitivity studies with respect to mesh size were performed, and a new 2-D mesh distribution developed after some problems were discovered with respect to the use of numerous elongated mesh cells in the reflector. All of the shielding analyses were performed sing the ANSL-V 39n/44g coupled library with 25 thermal neutron groups in order to obtain a rigorous representation of the thermal neutron spectrum throughout the reflector. Because of upscatter in the heavy water, convergence was very slow. Ultimately, the fission cross section in the various materials had to be artificially modified in order to solve this fixed source problem as an eigenvalue problem and invoke the Vondy error-mode extrapolation technique which greatly accelerated convergence in the large 2-D RZ DORT analyses. While this was quite effective, 150 outer iterations (over energy) were still required
Redefinition of the self-bias voltage in a dielectrically shielded thin sheath RF discharge
Ho, Teck Seng; Charles, Christine; Boswell, Rod
2018-05-01
In a geometrically asymmetric capacitively coupled discharge where the powered electrode is shielded from the plasma by a layer of dielectric material, the self-bias manifests as a nonuniform negative charging in the dielectric rather than on the blocking capacitor. In the thin sheath regime where the ion transit time across the powered sheath is on the order of or less than the Radiofrequency (RF) period, the plasma potential is observed to respond asymmetrically to extraneous impedances in the RF circuit. Consequently, the RF waveform on the plasma-facing surface of the dielectric is unknown, and the behaviour of the powered sheath is not easily predictable. Sheath circuit models become inadequate for describing this class of discharges, and a comprehensive fluid, electrical, and plasma numerical model is employed to accurately quantify this behaviour. The traditional definition of the self-bias voltage as the mean of the RF waveform is shown to be erroneous in this regime. Instead, using the maxima of the RF waveform provides a more rigorous definition given its correlation with the ion dynamics in the powered sheath. This is supported by a RF circuit model derived from the computational fluid dynamics and plasma simulations.
International Nuclear Information System (INIS)
Tarutani, Kohei
1979-01-01
Purpose: To decrease the stresses resulted by the core bendings to the base of an entrance nozzle. Constitution: Three types of round shielding rods of different diameter are arranged in a hexagonal tube. The hexagonal tube is provided with several spacer pads receiving the loads from the core constrain mechanism at its outer circumference, a handling head for a fuel exchanger at its top and an entrance nozzle for self-holding the neutron shieldings and flowing heat-removing coolants at its bottom. The diameters for R 1 , R 2 and R 3 for the round shielding rods are designed as: 0.1 R 1 2 1 and 0.2 R 1 2 1 . Since a plurality of shielding rods of small diameter are provided, soft structure are obtained and a plurality of coolant paths are formed. (Furukawa, Y.)
GROUPIE2007, Bondarenko Self-Shielded Cross sections from ENDF/B
International Nuclear Information System (INIS)
2007-01-01
1 - Description of problem or function - GROUPIE reads evaluated data in ENDF/B Format and uses these to calculate unshielded group averaged Cross sections, Bondarenko self-shielded Cross sections, and multiband parameters. The program allows the user to specify arbitrary energy groups and an arbitrary energy-dependent neutron spectrum (weighting function). IAEA0849/15: This version include the updates up to January 30, 2007. Changes in ENDF/B-VII Format and procedures, as well as the evaluations themselves, make it impossible for versions of the ENDF/B pre-processing codes earlier than PREPRO 2007 (2007 Version) to accurately process current ENDF/B-VII evaluations. The present code can handle all existing ENDF/B-VI evaluations through release 8, which will be the last release of ENDF/B-VI. 2 - Modifications from previous versions: Groupie VERS. 2007-1 (Jan. 2007): checked against all ENDF/B-VII; increased page size from 120,000 to 600,000 points. 3 - Method of solution: All integrals are performed analytically; in no case is iteration or any approximate form of integration used. GROUPIE reads either the 0 deg. Kelvin Cross sections or the Doppler broadened Cross sections to calculate the self-shielded Cross sections and multiband parameters for 25 values of the 'background' Cross sections (representing the combined effects of all other isotopes and of leakage). 4 - Restrictions on the complexity of the problem: GROUPIE requires that the energy-dependent neutron spectrum and all Cross sections be given in tabular form, with linear interpolation between tabulated values. There is no limit to the size of the table used to describe the spectrum, so the spectrum may be described in as much detail as required. - If only unshielded averages are calculated, the program can handle up to 3000 groups. If self-shielded averages and/or multiband parameters are calculated, the program can handle up to 175 groups. These limits can easily be extended. - The program only uses the
Kodama, Nao; Setoi, Ayana; Kose, Katsumi
2018-04-10
Spiral MRI sequences were developed for a 9.4T vertical standard bore (54 mm) superconducting magnet using unshielded and self-shielded gradient coils. Clear spiral images with 64-shot scan were obtained with the self-shielded gradient coil, but severe shading artifacts were observed for the spiral-scan images acquired with the unshielded gradient coil. This shading artifact was successfully corrected with a phase-correction technique using reference scans that we developed based on eddy current field measurements. We therefore concluded that spiral imaging sequences can be installed even for unshielded gradient coils if phase corrections are performed using the reference scans.
Open Rotor Noise Shielding by Blended-Wing-Body Aircraft
Guo, Yueping; Czech, Michael J.; Thomas, Russell H.
2015-01-01
This paper presents an analysis of open rotor noise shielding by Blended Wing Body (BWB) aircraft by using model scale test data acquired in the Boeing Low Speed Aeroacoustic Facility (LSAF) with a legacy F7/A7 rotor model and a simplified BWB platform. The objective of the analysis is the understanding of the shielding features of the BWB and the method of application of the shielding data for noise studies of BWB aircraft with open rotor propulsion. By studying the directivity patterns of individual tones, it is shown that though the tonal energy distribution and the spectral content of the wind tunnel test model, and thus its total noise, may differ from those of more advanced rotor designs, the individual tones follow directivity patterns that characterize far field radiations of modern open rotors, ensuring the validity of the use of this shielding data. Thus, open rotor tonal noise shielding should be categorized into front rotor tones, aft rotor tones and interaction tones, not only because of the different directivities of the three groups of tones, but also due to the differences in their source locations and coherence features, which make the respective shielding characteristics of the three groups of tones distinctly different from each other. To reveal the parametric trends of the BWB shielding effects, results are presented with variations in frequency, far field emission angle, rotor operational condition, engine installation geometry, and local airframe features. These results prepare the way for the development of parametric models for the shielding effects in prediction tools.
International Nuclear Information System (INIS)
Khattab, K.; Khamis, I.
2007-01-01
Measurement of the thermal self shielding coefficient ( Gth ) in the Syrian Miniature Neutron Source Reactor (MNSR) inner irradiation site using Dy foils is presented in this paper. The thermal self shielding coefficient is measured as a function of the foil thickness or numbers. The mathematical equation which calculates the average relative radioactivity (Bq/g) versus the foil number is found as well.
Self-similar regimes of fast ionization waves in shielded discharge tubes
International Nuclear Information System (INIS)
Gerasimov, D.N.; Sinkevich, O.A.
1999-01-01
An analytical self-similar solution to the problem of the propagation of a fast ionization wave (FIW) in a long shielded tube is constructed. An expression determining the influence of the device parameters on the FIW velocity is obtained; the velocity is found to be the nonmonotonic function of the working-gas pressure. The theoretical predictions are compared with the results of experiments carried out with helium and nitrogen. The calculation and experimental results agree within experimental errors
Modelling the electrical properties of concrete for shielding effectiveness prediction
International Nuclear Information System (INIS)
Sandrolini, L; Reggiani, U; Ogunsola, A
2007-01-01
Concrete is a porous, heterogeneous material whose abundant use in numerous applications demands a detailed understanding of its electrical properties. Besides experimental measurements, material theoretical models can be useful to investigate its behaviour with respect to frequency, moisture content or other factors. These models can be used in electromagnetic compatibility (EMC) to predict the shielding effectiveness of a concrete structure against external electromagnetic waves. This paper presents the development of a dispersive material model for concrete out of experimental measurement data to take account of the frequency dependence of concrete's electrical properties. The model is implemented into a numerical simulator and compared with the classical transmission-line approach in shielding effectiveness calculations of simple concrete walls of different moisture content. The comparative results show good agreement in all cases; a possible relation between shielding effectiveness and the electrical properties of concrete and the limits of the proposed model are discussed
International Nuclear Information System (INIS)
Leal, L.C.; de Saussure, G.; Perez, R.B.
1990-01-01
The URR computer code has been developed to calculate cross-section probability tables, Bondarenko self-shielding factors, and self-indication ratios for fertile and fissile isotopes in the unresolved resonance region. Monte Carlo methods are utilized to select appropriate resonance parameters and to compute the cross sections at the desired reference energy. The neutron cross sections are calculated by the single-level Breit-Wigner formalism with s-, p-, and d-wave contributions. The cross-section probability tables are constructed by sampling by Doppler broadened cross-sections. The various self-shielding factors are computer numerically as Lebesgue integrals over the cross-section probability tables
Kodama, Nao; Setoi, Ayana; Kose, Katsumi
2018-01-01
Spiral MRI sequences were developed for a 9.4T vertical standard bore (54 mm) superconducting magnet using unshielded and self-shielded gradient coils. Clear spiral images with 64-shot scan were obtained with the self-shielded gradient coil, but severe shading artifacts were observed for the spiral-scan images acquired with the unshielded gradient coil. This shading artifact was successfully corrected with a phase-correction technique using reference scans that we developed based on eddy current field measurements. We therefore concluded that spiral imaging sequences can be installed even for unshielded gradient coils if phase corrections are performed using the reference scans. PMID:28367906
Analytic Ballistic Performance Model of Whipple Shields
Miller, J. E.; Bjorkman, M. D.; Christiansen, E. L.; Ryan, S. J.
2015-01-01
The dual-wall, Whipple shield is the shield of choice for lightweight, long-duration flight. The shield uses an initial sacrificial wall to initiate fragmentation and melt an impacting threat that expands over a void before hitting a subsequent shield wall of a critical component. The key parameters to this type of shield are the rear wall and its mass which stops the debris, as well as the minimum shock wave strength generated by the threat particle impact of the sacrificial wall and the amount of room that is available for expansion. Ensuring the shock wave strength is sufficiently high to achieve large scale fragmentation/melt of the threat particle enables the expansion of the threat and reduces the momentum flux of the debris on the rear wall. Three key factors in the shock wave strength achieved are the thickness of the sacrificial wall relative to the characteristic dimension of the impacting particle, the density and material cohesion contrast of the sacrificial wall relative to the threat particle and the impact speed. The mass of the rear wall and the sacrificial wall are desirable to minimize for launch costs making it important to have an understanding of the effects of density contrast and impact speed. An analytic model is developed here, to describe the influence of these three key factors. In addition this paper develops a description of a fourth key parameter related to fragmentation and its role in establishing the onset of projectile expansion.
International Nuclear Information System (INIS)
Liu Haibo; Wu Yican; Zheng Shanliang; Zhang Chunzao
2004-01-01
Based on the Fusion-Driven Subcritical System (FDS-I), the 25 groups, 175 groups and 620 groups neutron nuclear data libraries with/without resonance self-shielding correction are made with the Njoy and Transx codes, and the K eff and reaction rates are calculated with the Anisn code. The conclusion indicates that the resonance self-shielding effect affects the reaction rates strongly. (authors)
Radiation shielding for fission reactors
Energy Technology Data Exchange (ETDEWEB)
Oka, Yoshiaki [Tokyo Univ., Nuclear Engineering Research Laboratory, Tokyo (Japan)
2000-03-01
Radiation shielding aspects relating fission reactors have been reviewed. Domestic activities in the past five years have been mainly described concerning nuclear data, calculation methods, shielding and skyshine experiments, Advanced Boiling Water Reactor (ABWR), Advanced Pressurized Water Reactor (APWR), High Temperature Engineering Test Reactor (HTTR), Experimental and Prototype Fast Reactors (JOYO, MONJU), Demonstration FBR, core shroud replacement of BWR, and spent fuel transportation cask and vessel. These studies have valuable information in safety and cost reduction issues of fission reactor design for not only existing reactors but also new reactor concepts in the next century. It has been concluded that we should maintain existing shielding technologies and improve these data and methods for coming generations in the next millennium. (author)
[The model of radiation shielding of the service module of the International space station].
Kolomenskiĭ, A V; Kuznetsov, V G; Laĭko, Iu A; Bengin, V V; Shurshakov, V A
2001-01-01
Compared and contrasted were models of radiation shielding of habitable compartments of the basal Mir module that had been used to calculate crew absorbed doses from space radiation. Developed was a model of the ISS Service module radiation shielding. It was stated that there is a good agreement between experimental shielding function and the one calculated from this model.
Experiment and analysis of CASTOR type model cask for verification of radiation shielding
Energy Technology Data Exchange (ETDEWEB)
Hattori, Seiichi; Ueki, Kohtaro.
1988-08-01
The radiation shielding system of CASTOR type cask is composed of the graphite cast iron and the polyethylene lod. The former fomes the cylndrical body of the cask to shield gamma rays and the latter is embeded in the body to shield neutrons. Characteristic of radiation shielding of CASTOR type cask is that zigzag arrangement of the polyethylene lod is adopted to unify the penetrating dose rate. It is necessary to use the three-dimensional analysis code to analyse the shielding performance of the cask with the complicated shielding system precisely. However, it takes too much time as well as too much cost. Therefore, the two-dimensional analysis is usually applied, in which the three-dimensional model is equivalently transformed into the two-dimensional calculation. The reseach study was conducted to verify the application of the two-dimensional analysis, in which the experiment and the analysis using CASTOR type model cask was perfomed. The model cask was manufactured by GNS campany in West Germany and the shielding ability test facilities in CRIEPI were used. It was judged from the study that the two-dimensional analysis is useful means for the practical use.
Comparison among Models to Estimate the Shielding Effectiveness Applied to Conductive Textiles
Directory of Open Access Journals (Sweden)
Alberto Lopez
2013-01-01
Full Text Available The purpose of this paper is to present a comparison among two models and its measurement to calculate the shielding effectiveness of electromagnetic barriers, applying it to conductive textiles. Each one, models a conductive textile as either a (1 wire mesh screen or (2 compact material. Therefore, the objective is to perform an analysis of the models in order to determine which one is a better approximation for electromagnetic shielding fabrics. In order to provide results for the comparison, the shielding effectiveness of the sample has been measured by means of the standard ASTM D4935-99.
International Nuclear Information System (INIS)
Sudarshan, K.; Tripathi, R.; Nair, A.G.C.; Acharya, R.; Reddy, A.V.R.; Goswami, A.
2005-01-01
A simple method using an internal standard is proposed to correct for the self-shielding effect of B, Cd and Gd in a matrix. This would increase the linear dynamic range of PGNAA in analyzing samples containing these elements. The method is validated by analyzing synthetic samples containing large amounts of B, Cd, Hg and Gd, the elements having high neutron absorption cross-section, in aqueous solutions and solid forms. A simple Monte-Carlo simulation to find the extent of self-shielding in the matrix is presented. The method is applied to the analysis of titanium boride alloy containing large amount of boron. The satisfactory results obtained showed the efficacy of the method of correcting for the self-shielding effects in the sample
International Nuclear Information System (INIS)
Froehner, F.H.; Larson, Duane C.; Tagesen, Siegfried; Petrizzi, Luigi; Hasegawa, Akira; Nakagawa, Tsuneo; Hogenbirk, Alfred; Weigmann, H.
1995-01-01
A Working Party on International Evaluation Co-operation was established under the sponsorship of the OECD/NEA Nuclear Science Committee (NSC) to promote the exchange of information on nuclear data evaluations, validation, and related topics. Its aim is also to provide a framework for co-operative activities between members of the major nuclear data evaluation projects. This includes the possible exchange of scientists in order to encourage co-operation. Requirements for experimental data resulting from this activity are compiled. The Working Party determines common criteria for evaluated nuclear data files with a view to assessing and improving the quality and completeness of evaluated data. The Parties to the project are: ENDF (United States), JEFF/EFF (NEA Data Bank Member countries), and JENDL (Japan). Co-operation with evaluation projects of non-OECD countries are organised through the Nuclear Data Section of the International Atomic Energy Agency (IAEA). NEA/NSC Subgroup 15 has had the task to assess self-shielding effects in the unresolved resonance range of structural materials, in particular their importance at various energies, and possible ways to deal with them in shielding and activation work. The principal results achieved are summarised briefly, in particular: - New data base consisting of high-resolution transmission data measured at Oak Ridge and Geel; - Improved theoretical understanding of cross-section fluctuations, including their prediction, that has been derived from the Hauser-Feshbach theory; - Benchmark results on the importance of self-shielding in iron at various energies; - Consequences for information storage in evaluated nuclear data files; - Practical utilisation of self-shielding information from evaluated files. Benchmark results as well as the Hauser-Feshbach theory show that self-shielding effects are important up to a 4-or 5-MeV neutron energy. Fluctuation factors extracted from high-resolution total cross-section data can be
Influence of the Radiation Shield on the Temperature of Rails Rolled in the Reversing Mill
Directory of Open Access Journals (Sweden)
Gołdasz A.
2015-04-01
Full Text Available The paper presents a mathematical model of heat transfer during cooling of hot-rolled rails in the reversing mill. The influence of the radiation shield on the temperature of rolled rails has been analyzed. The heat transfer model for cooling a strip covered by the thermal shield has been presented. The two types of shields build of steel and aluminum sheets separated with insulating layer have been studded. Calculations have been performed with self developed software which utilizes the finite element method.
RSMASS: A simple model for estimating reactor and shield masses
International Nuclear Information System (INIS)
Marshall, A.C.; Aragon, J.; Gallup, D.
1987-01-01
A simple mathematical model (RSMASS) has been developed to provide rapid estimates of reactor and shield masses for space-based reactor power systems. Approximations are used rather than correlations or detailed calculations to estimate the reactor fuel mass and the masses of the moderator, structure, reflector, pressure vessel, miscellaneous components, and the reactor shield. The fuel mass is determined either by neutronics limits, thermal/hydraulic limits, or fuel damage limits, whichever yields the largest mass. RSMASS requires the reactor power and energy, 24 reactor parameters, and 20 shield parameters to be specified. This parametric approach should be applicable to a very broad range of reactor types. Reactor and shield masses calculated by RSMASS were found to be in good agreement with the masses obtained from detailed calculations
Adaptive algorithms for a self-shielding wavelet-based Galerkin method
International Nuclear Information System (INIS)
Fournier, D.; Le Tellier, R.
2009-01-01
The treatment of the energy variable in deterministic neutron transport methods is based on a multigroup discretization, considering the flux and cross-sections to be constant within a group. In this case, a self-shielding calculation is mandatory to correct sections of resonant isotopes. In this paper, a different approach based on a finite element discretization on a wavelet basis is used. We propose adaptive algorithms constructed from error estimates. Such an approach is applied to within-group scattering source iterations. A first implementation is presented in the special case of the fine structure equation for an infinite homogeneous medium. Extension to spatially-dependent cases is discussed. (authors)
CO Self-Shielding as a Mechanism to Make O-16 Enriched Solids in the Solar Nebula
Nuth, Joseph A. III; Johnson, Natasha M.; Hill, Hugh G. M.
2014-01-01
Photochemical self-shielding of CO has been proposed as a mechanism to produce solids observed in the modern, O-16 depleted solar system. This is distinct from the relatively O-16 enriched composition of the solar nebula, as demonstrated by the oxygen isotopic composition of the contemporary sun. While supporting the idea that self-shielding can produce local enhancements in O-16 depleted solids, we argue that complementary enhancements of O-16 enriched solids can also be produced via CO-16 based, Fischer-Tropsch type (FTT) catalytic processes that could produce much of the carbonaceous feedstock incorporated into accreting planetesimals. Local enhancements could explain observed O-16 enrichment in calcium-aluminum-rich inclusions (CAIs), such as those from the meteorite, Isheyevo (CH/CHb), as well as in chondrules from the meteorite, Acfer 214 (CH3). CO selfshielding results in an overall increase in the O-17 and O-18 content of nebular solids only to the extent that there is a net loss of CO-16 from the solar nebula. In contrast, if CO-16 reacts in the nebula to produce organics and water then the net effect of the self-shielding process will be negligible for the average oxygen isotopic content of nebular solids and other mechanisms must be sought to produce the observed dichotomy between oxygen in the Sun and that in meteorites and the terrestrial planets. This illustrates that the formation and metamorphism of rocks and organics need to be considered in tandem rather than as isolated reaction networks.
Recent trends in radiation shielding: a RSIC perspective
International Nuclear Information System (INIS)
Trubey, D.K.; Roussin, R.W.; Maskewitz, B.F.
1979-01-01
The subject of radiation transport and shielding in the nuclear power industry is reviewed, and advances in the state of the art are described. These fall into the areas of computational methods, nuclear cross sections, industry practices, and standards. Computer codes and data available from the Radiation Shielding Information Center (RSIC) representing recent advances are also described
Radiation shield for PWR reactors
International Nuclear Information System (INIS)
Esenov, Amra; Pustovgar, Andrey
2013-01-01
One of the chief structures of a reactor pit is a 'dry' shield. Setting up a 'dry' shield includes the technologically complex process of thermal processing of serpentinite concrete. Modern advances in the area of materials technology permit avoiding this complex and demanding procedure, and this significantly decreases the duration, labor intensity, and cost of setting it up. (orig.)
MicroShield/ISOCS gamma modeling comparison.
Energy Technology Data Exchange (ETDEWEB)
Sansone, Kenneth R
2013-08-01
Quantitative radiological analysis attempts to determine the quantity of activity or concentration of specific radionuclide(s) in a sample. Based upon the certified standards that are used to calibrate gamma spectral detectors, geometric similarities between sample shape and the calibration standards determine if the analysis results developed are qualitative or quantitative. A sample analyzed that does not mimic a calibrated sample geometry must be reported as a non-standard geometry and thus the results are considered qualitative and not quantitative. MicroShieldR or ISOCSR calibration software can be used to model non-standard geometric sample shapes in an effort to obtain a quantitative analytical result. MicroShieldR and Canberras ISOCSR software contain several geometry templates that can provide accurate quantitative modeling for a variety of sample configurations. Included in the software are computational algorithms that are used to develop and calculate energy efficiency values for the modeled sample geometry which can then be used with conventional analysis methodology to calculate the result. The response of the analytical method and the sensitivity of the mechanical and electronic equipment to the radionuclide of interest must be calibrated, or standardized, using a calibrated radiological source that contains a known and certified amount of activity.
ORNL neutral gas shielding model for pellet-plasma interactions
International Nuclear Information System (INIS)
Milora, S.L; Foster, C.A.
1977-05-01
A revised neutral molecule ablation model is derived to describe the evaporation of a solid hydrogen pellet in a tokamak plasma. The approach taken is based on the theory of Parks, Turnbull, and Foster who postulate that a cloud of molecular hydrogen surrounding the pellet shields the surface from incoming energetic electrons and, in so doing, regulates the evaporation rate. This treatment differs from an earlier model in that the hydrodynamic behavior of the molecular cloud is treated in a self-consistent manner. Numerical solutions of the fluid dynamic equations, which include the effects of strong electron heating locally in the gas, reveal that the flow of material away from the pellet is initially retarded by the heating and then rapidly accelerated and rarefied. This behavior is more pronounced for higher temperature plasmas and the net effect is that pellet lifetimes are prolonged slightly by including the heating effects. A comparison is made with the results of the recent pellet injection experiments on ORMAK and a simple injection depth scaling law is derived
Neutron shielding studies on an advanced molten salt fast reactor design
International Nuclear Information System (INIS)
Merk, Bruno; Konheiser, Jörg
2014-01-01
Highlights: • Material damage due to irradiation has already been discovered at the MSRE. • Neutronic analysis of MSFR with curved blanket wall geometry. • Neutron fluence limit at the wall of the outer vessel can be kept for 80 years. • Shielded MSFR core will be of same dimension than a SFR core. - Abstract: The molten salt reactor technology has gained some new interest. In contrast to the historic molten salt reactors, the current projects are based on designing a molten salt fast reactor. Thus the shielding becomes significantly more challenging than in historic concepts. One very interesting and innovative result of the most recent EURATOM project on molten salt reactors – EVOL – is the fluid flow optimized design of the inner reactor vessel using curved blanket walls. The developed structure leads to a very uniform flow distribution. The design avoids all internal structures. Based on this new geometry a model for neutron physics calculation is presented. The major steps are: the modeling of the curved geometry in the unstructured mesh neutron transport code HELIOS and the determination of the real neutron flux and power distribution for this new geometry. The developed model is then used for the determination of the neutron fluence distribution in the inner and outer wall of the system. Based on these results an optimized shielding strategy is developed for the molten salt fast reactor to keep the fluence in the safety related outer vessel below expected limit values. A lifetime of 80 years can be assured, but the size of the core/blanket system will be comparable to a sodium cooled fast reactor. The HELIOS results are verified against Monte-Carlo calculations with very satisfactory agreement for a deep penetration problem
International Nuclear Information System (INIS)
Ganesan, S.; Gopalakrishnan, V.; Ramanadhan, M.M.; Cullan, D.E.
1986-01-01
We investigate the effect of interpolation error in the pre-processing codes LINEAR, RECENT and SIGMA1 on calculations of self-shielding factors and their temperature derivatives. We consider the 2.0347 to 3.3546 keV energy region for 238 U capture, which is the NEACRP benchmark exercise on unresolved parameters. The calculated values of temperature derivatives of self-shielding factors are significantly affected by interpolation error. The sources of problems in both evaluated data and codes are identified and eliminated in the 1985 version of these codes. This paper helps to (1) inform code users to use only 1985 versions of LINEAR, RECENT, and SIGMA1 and (2) inform designers of other code systems where they may have problems and what to do to eliminate their problems. (author)
International Nuclear Information System (INIS)
Ganesan, S.; Gopalakrishnan, V.; Ramanadhan, M.M.; Cullen, D.E.
1985-01-01
The authors investigate the effect of interpolation error in the pre-processing codes LINEAR, RECENT and SIGMA1 on calculations of self-shielding factors and their temperature derivatives. They consider the 2.0347 to 3.3546 keV energy region for /sup 238/U capture, which is the NEACRP benchmark exercise on unresolved parameters. The calculated values of temperature derivatives of self-shielding factors are significantly affected by interpolation error. The sources of problems in both evaluated data and codes are identified and eliminated in the 1985 version of these codes. This paper helps to (1) inform code users to use only 1985 versions of LINEAR, RECENT, and SIGMA1 and (2) inform designers of other code systems where they may have problems and what to do to eliminate their problems
MINX, Multigroup Cross-Sections and Self-Shielding Factors from ENDF/B for Program SPHINX
International Nuclear Information System (INIS)
Soran, P.D.; MacFarlane, R.E.; Harris, D.R.; LaBauve, R.J.; Hendricks, J.S.; Kidman, R.B.; Weisbin, C.R.; White, J.E.
1977-01-01
1 - Description of problem or function: MINX calculates fine-group averaged infinitely diluted cross sections and self-shielding factors from ENDF/B-IV data. Its primary purpose is to generate a pseudo-composition-independent multigroup library which is input to the SPHINX space-energy collapse program (2) (PSR-0129) through standard CCCC-III (8) interfaces. MINX incorporates and improves upon the resonance capabilities of existing codes such as ETOX (5) (NESC0388) and ENDRUN (9) and the high-order group-to-group transfer matrices of SUPERTOG (10) (PSR-0013) and ETOG (11). Fine group energy boundaries, Legendre expansion order, gross spectral shape component (in the Bondarenko flux model), temperatures and dilutions can all be used specifically. 2 - Method of solution: Infinitely dilute, un-broadened point cross sections are obtained from resolved resonance parameters using a modified version of the RESEND program (3) (NESC0465). The SIGMA1 (4) (IAEA0854) kernel-broadening method is used to Doppler broaden and thin the tabulated linearized pointwise cross sections at 0 K (outside of the unresolved energy region). Effective temperature- dependent self-shielded pointwise cross sections are derived from the formulation in the ETOX code. The primary modification to the ETOX algorithm is associated with the numerical quadrature scheme used to establish the mean values of the fluctuation intervals. The selection of energy mesh points, at which the effective cross sections are calculated, has been modified to include the energy points given in the ENDF/B file or, if the energy-independent formalism was employed, points at half-lethargy intervals. Infinitely dilute group cross sections and self-shielding factors are generated using the Bondarenko flux weighting model with the gross spectral shape under user control. The integral over energy for each group is divided into a set of panels defined by the union of the grid points describing the total cross section, the
Energy Technology Data Exchange (ETDEWEB)
Coste, M.
1994-01-01
This note gives in detailed way the self-shielding formalism which is used in the multigroup transport code APOLLO2. The self-shielded cross-sections are performed with the same scheme as in APOLLO1. We use two equivalencies, first an heterogeneous/homogeneous equivalence which gives the reaction rates and then a multigroup equivalence in order to obtain the cross-sections which preserve these reaction rates. However, numerous improvements were implemented, specially in the homogenization step. Homogenization can be performed group per group with different modelizations of the heavy slowing-down operator (statistical, intermediary and ``wide resonance`` models), which allows us to fit correctly the resonance shapes. Moreover, we can take exactly into account the spatial interferences between resonant isotopes with the background matrix model. Consequently, we are now able to perform, for instance, the radial distribution of the resonant absorption inside a fuel pin. (author). 7 refs., 3 figs.
System modeling for the advanced thermionic initiative single cell thermionic space nuclear reactor
International Nuclear Information System (INIS)
Lee, H.H.; Lewis, B.R.; Klein, A.C.; Pawlowski, R.A.
1993-01-01
Incore thermionic space reactor design concepts which operate in a nominal power output range of 20 to 40 kWe are described. Details of the neutronics, thermionic, shielding, and heat rejection performance are presented. Two different designs, ATI-Driven and ATI-Driverless, are considered. Comparison of the core overall performance of these two configurations are described. The comparison of these two cores includes the overall conversion efficiency, reactor mass, shield mass, and heat rejection mass. An overall system design has been developed to model the advanced incore thermionic energy conversion based nuclear reactor systems for space applications in this power range
Radiation dose reduction by water shield
International Nuclear Information System (INIS)
Zeb, J.; Arshed, W.; Ahmad, S.S.
2007-06-01
This report is an operational manual of shielding software W-Shielder, developed at Health Physics Division (HPD), Pakistan Institute of Nuclear Science and Technology (PINSTECH), Pakistan Atomic Energy Commission. The software estimates shielding thickness for photons having their energy in the range 0.5 to 10 MeV. To compute the shield thickness, self absorption in the source has been neglected and the source has been assumed as a point source. Water is used as a shielding material in this software. The software is helpful in estimating the water thickness for safe handling, storage of gamma emitting radionuclide. (author)
Resonance self-shielding calculation with regularized random ladders
Energy Technology Data Exchange (ETDEWEB)
Ribon, P.
1986-01-01
The straightforward method for calculation of resonance self-shielding is to generate one or several resonance ladders, and to process them as resolved resonances. The main drawback of Monte Carlo methods used to generate the ladders, is the difficulty of reducing the dispersion of data and results. Several methods are examined, and it is shown how one (a regularized sampling method) improves the accuracy. Analytical methods to compute the effective cross-section have recently appeared: they are basically exempt from dispersion, but are inevitably approximate. The accuracy of the most sophisticated one is checked. There is a neutron energy range which is improperly considered as statistical. An examination is presented of what happens when it is treated as statistical, and how it is possible to improve the accuracy of calculations in this range. To illustrate the results calculations have been performed in a simple case: nucleus /sup 238/U, at 300 K, between 4250 and 4750 eV.
Walker, Steven A.; Clowdsley, Martha S.; Abston, H. Lee; Simon, Hatthew A.; Gallegos, Adam M.
2013-01-01
NASA has plans for long duration missions beyond low Earth orbit (LEO). Outside of LEO, large solar particle events (SPEs), which occur sporadically, can deliver a very large dose in a short amount of time. The relatively low proton energies make SPE shielding practical, and the possibility of the occurrence of a large event drives the need for SPE shielding for all deep space missions. The Advanced Exploration Systems (AES) RadWorks Storm Shelter Team was charged with developing minimal mass SPE storm shelter concepts for missions beyond LEO. The concepts developed included "wearable" shields, shelters that could be deployed at the onset of an event, and augmentations to the crew quarters. The radiation transport codes, human body models, and vehicle geometry tools contained in the On-Line Tool for the Assessment of Radiation In Space (OLTARIS) were used to evaluate the protection provided by each concept within a realistic space habitat and provide the concept designers with shield thickness requirements. Several different SPE models were utilized to examine the dependence of the shield requirements on the event spectrum. This paper describes the radiation analysis methods and the results of these analyses for several of the shielding concepts.
International Nuclear Information System (INIS)
Leal, L.C.; de Saussure, G.; Perez, R.B.
1989-01-01
The URR computer code has been developed to calculate cross-section probability tables, Bondarenko self-shielding factors, and self- indication ratios for fertile and fissile isotopes in the unresolved resonance region. Monte Carlo methods are utilized to select appropriate resonance parameters and to compute the cross sections at the desired reference energy. The neutron cross sections are calculated by the single-level Breit-Wigner formalism with s-, p-, and d-wave contributions. The cross-section probability tables are constructed by sampling the Doppler broadened cross-section. The various shelf-shielded factors are computed numerically as Lebesgue integrals over the cross-section probability tables. 6 refs
Penetration shielding applications of CYLSEC
International Nuclear Information System (INIS)
Dexheimer, D.T.; Hathaway, J.M.
1985-01-01
Evaluation of penetration and discontinuity shielding is necessary to meet 10CFR20 regulations for ensuring personnel exposures are as low as reasonably achievable (ALARA). Historically, those shielding evaluations have been done to some degree on all projects. However, many early plants used conservative methods due to lack of an economical computer code, resulting in costly penetration shielding programs. With the increased industry interest in cost effectively reducing personnel exposures to meet ALARA regulations and with the development of the CYLSEC gamma transport computer code at Bechtel, a comprehensive effort was initiated to reduce penetration and discontinuity shielding but still provide a prudent degree of protection for plant personnel from radiation streaming. This effort was more comprehensive than previous programs due to advances in shielding analysis technology and increased interest in controlling project costs while maintaining personnel exposures ALARA. Methodology and resulting cost savings are discussed
Shielding Calculations for PUSPATI TRIGA Reactor (RTP) Fuel Transfer Cask with Micro shield
International Nuclear Information System (INIS)
Nurhayati Ramli; Ahmad Nabil Abdul Rahim; Ariff Shah Ismail
2011-01-01
The shielding calculations for RTP fuel transfer cask was performed by using computer code Micro shield 7.02. Micro shield is a computer code designed to provide a model to be used for shielding calculations. The results of the calculations can be obtained fast but the code is not suitable for complex geometries with a shielding composed of more than one material. Nevertheless, the program is sufficient for As Low As Reasonable Achievable (ALARA) optimization calculations. In this calculation, a geometry based on the conceptual design of RTP fuel transfer cask was modeled. Shielding material used in the calculations were lead (Pb) and stainless steel 304 (SS304). The results obtained from these calculations are discussed in this paper. (author)
Shielded cells transfer automation
International Nuclear Information System (INIS)
Fisher, J.J.
1984-01-01
Nuclear waste from shielded cells is removed, packaged, and transferred manually in many nuclear facilities. Radiation exposure is absorbed by operators during these operations and limited only through procedural controls. Technological advances in automation using robotics have allowed a production waste removal operation to be automated to reduce radiation exposure. The robotic system bags waste containers out of glove box and transfers them to a shielded container. Operators control the system outside the system work area via television cameras. 9 figures
A 2D semi-analytical model for Faraday shield in ICP source
International Nuclear Information System (INIS)
Zhang, L.G.; Chen, D.Z.; Li, D.; Liu, K.F.; Li, X.F.; Pan, R.M.; Fan, M.W.
2016-01-01
Highlights: • In this paper, a 2D model of ICP with faraday shield is proposed considering the complex structure of the Faraday shield. • Analytical solution is found to evaluate the electromagnetic field in the ICP source with Faraday shield. • The collision-free motion of electrons in the source is investigated and the results show that the electrons will oscillate along the radial direction, which brings insight into how the RF power couple to the plasma. - Abstract: Faraday shield is a thin copper structure with a large number of slits which is usually used in inductive coupled plasma (ICP) sources. RF power is coupled into the plasma through these slits, therefore Faraday shield plays an important role in ICP discharge. However, due to the complex structure of the Faraday shield, the resulted electromagnetic field is quite hard to evaluate. In this paper, a 2D model is proposed on the assumption that the Faraday shield is sufficiently long and the RF coil is uniformly distributed, and the copper is considered as ideal conductor. Under these conditions, the magnetic field inside the source is uniform with only the axial component, while the electric field can be decomposed into a vortex field generated by changing magnetic field together with a gradient field generated by electric charge accumulated on the Faraday shield surface, which can be easily found by solving Laplace's equation. The motion of the electrons in the electromagnetic field is investigated and the results show that the electrons will oscillate along the radial direction when taking no account of collision. This interesting result brings insight into how the RF power couples into the plasma.
Validation of nuclear models used in space radiation shielding applications
International Nuclear Information System (INIS)
Norman, Ryan B.; Blattnig, Steve R.
2013-01-01
A program of verification and validation has been undertaken to assess the applicability of models to space radiation shielding applications and to track progress as these models are developed over time. In this work, simple validation metrics applicable to testing both model accuracy and consistency with experimental data are developed. The developed metrics treat experimental measurement uncertainty as an interval and are therefore applicable to cases in which epistemic uncertainty dominates the experimental data. To demonstrate the applicability of the metrics, nuclear physics models used by NASA for space radiation shielding applications are compared to an experimental database consisting of over 3600 experimental cross sections. A cumulative uncertainty metric is applied to the question of overall model accuracy, while a metric based on the median uncertainty is used to analyze the models from the perspective of model development by examining subsets of the model parameter space.
Nuth, Joseph A., III; Johnson, Natasha M.
2012-01-01
There are at least 3 separate photochemical self-shielding models with different degrees of commonality. All of these models rely on the selective absorption of (12))C(16)O dissociative photons as the radiation source penetrates through the gas allowing the production of reactive O-17 and O-18 atoms within a specific volume. Each model also assumes that the undissociated C(16)O is stable and does not participate in the chemistry of nebular dust grains. In what follows we will argue that this last, very important assumption is simply not true despite the very high energy of the CO molecular bond.
Radiation shielding lead shield
International Nuclear Information System (INIS)
Dei, Shoichi.
1991-01-01
The present invention concerns lead shields for radiation shielding. Shield boxes are disposed so as to surround a pipeline through which radioactive liquids, mists or like other objects are passed. Flanges are formed to each of the end edges of the shield boxes and the shield boxes are connected to each other by the flanges. Upon installation, empty shield boxes not charged with lead particles and iron plate shields are secured at first at the periphery of the pipeline. Then, lead particles are charged into the shield boxes. This attains a state as if lead plate corresponding to the depth of the box is disposed. Accordingly, operations for installation, dismantling and restoration can be conducted in an empty state with reduced weight to facilitate the operations. (I.S.)
Directory of Open Access Journals (Sweden)
Xianhong Li
2013-01-01
Full Text Available A general nonlinear time-varying (NLTV dynamic model and linear time-varying (LTV dynamic model are presented for shield tunnel boring machine (TBM cutterhead driving system, respectively. Different gear backlashes and mesh damped and transmission errors are considered in the NLTV dynamic model. The corresponding multiple-input and multiple-output (MIMO state space models are also presented. Through analyzing the linear dynamic model, the optimal reducer ratio (ORR and optimal transmission ratio (OTR are obtained for the shield TBM cutterhead driving system, respectively. The NLTV and LTV dynamic models are numerically simulated, and the effects of physical parameters under various conditions of NLTV dynamic model are analyzed. Physical parameters such as the load torque, gear backlash and transmission error, gear mesh stiffness and damped, pinions inertia and damped, large gear inertia and damped, and motor rotor inertia and damped are investigated in detail to analyze their effects on dynamic response and performances of the shield TBM cutterhead driving system. Some preliminary approaches are proposed to improve dynamic performances of the cutterhead driving system, and dynamic models will provide a foundation for shield TBM cutterhead driving system's cutterhead fault diagnosis, motion control, and torque synchronous control.
Superhydrophobic coatings on wood substrate for self-cleaning and EMI shielding
Xing, Yingjie; Xue, Yaping; Song, Jinlong; Sun, Yankui; Huang, Liu; Liu, Xin; Sun, Jing
2018-04-01
A layer of superhydrophobic coating having good electromagnetic shielding and self-cleaning performance was fabricated on a wood surface through an electroless copper plated process. The superhydrophobic property of the wood surface was measured by contact angle (CA) and roll-off angle (RA) measurements. The microstructure and chemical composition of the superhydrophobic coating were analyzed by scanning electron microscopy (SEM), energy dispersive spectrometer (EDS) and X-ray diffraction (XRD). The analysis revealed that the microscale particles were uniformly distributed on the wood surface and the main component of the coating is metallic copper. The as-prepared Cu coatings on wood substrate exhibit a good superhydrophobicity with water contact angle about 160° and rolling angle less than 5°.
MATHEMATICAL MODELLING OF THE SHIELDING EFFECTIVENESS FOR PES/STAINLESS STEEL FABRICS
Directory of Open Access Journals (Sweden)
RADULESCU Ion Razvan
2017-05-01
Full Text Available Textile screens for electromagnetic radiation represent a modern solution, due to their flexibility, lightweight and good mechanical resistance. Electromagnetic shielding is a must in various applications, while strict regulations are set for electromagnetic compatibility. Conductive fabrics are widely used for electronic equipment covers, RF suits or EMI protection tents. This paper aims to investigate the shielding effectiveness of conductive woven fabrics with stainless steel yarns at different weft distances [2,3,4,5 mm]. These conductive fabrics were investigated for their physical-mechanical properties (mass per surface unit, density on warp and weft direction and thickness, within the INCDTP accredited laboratories. The conductive fabrics as well as combinations thereof where tested for their shielding effectiveness accordingly to the standard ASTM ES 07, within the EMC laboratories of ICPE-CA. A signal generator, an amplifier, a TEM Cell and a spectrum analyser were used were used for this purpose. Graphs in logarithmic scale were issued for the shielding effectiveness analysis. Moreover, an experimental factorial plan was conceived for obtaining a mathematical model for the studied fabrics in relation to the weft distance between the conductive yarns. The coefficients of the mathematical model were obtained through the least squares regression method in Excel, while the response curve was designed in Matlab. The response curve enables the computation of intermediate values of the shielding effectiveness in relation to the distance between conductive yarns.
Survivor shielding. Part C. Improvements in terrain shielding
International Nuclear Information System (INIS)
Egbert, Stephen D.; Kaul, Dean C.; Roberts, James A.; Kerr, George D.
2005-01-01
A number of atomic-bomb survivors were affected by shielding provided by terrain features. These terrain features can be a small hill, affecting one or two houses, or a high mountain that shields large neighborhoods. In the survivor dosimetry system, terrain shielding can be described by a transmission factor (TF), which is the ratio between the dose with and without the terrain present. The terrain TF typically ranges between 0.1 and 1.0. After DS86 was implemented at RERF, the terrain shielding categories were examined and found to either have a bias or an excessive uncertainty that could readily be removed. In 1989, an improvement in the terrain model was implemented at RERF in the revised DS86 code, but the documentation was not published. It is now presented in this section. The solution to the terrain shielding in front of a house is described in this section. The problem of terrain shielding of survivors behind Hijiyama mountain at Hiroshima and Konpirasan mountain at Nagasaki has also been recognized, and a solution to this problem has been included in DS02. (author)
The new solid target system at UNAM in a self-shielded 11 MeV cyclotron
International Nuclear Information System (INIS)
Zarate-Morales, A.; Gaspar-Carcamo, R. E.; Lopez-Rodriguez, V.; Flores-Moreno, A.; Trejo-Ballado, F.; Avila-Rodriguez, Miguel A.
2012-01-01
A dual beam line (BL) self-shielded RDS 111 cyclotron for radionuclide production was installed at the School of Medicine of the National Autonomous University of Mexico in 2001. One of the BL’s was upgraded to Eclipse HP (Siemens) in 2008 and the second BL was recently upgraded (June 2011) to the same version with the option for the irradiation of solid targets for the production of metallic radioisotopes.
International Nuclear Information System (INIS)
Kamble, Granthali S.; Manisha, V.; Venkatesh, K.
2015-01-01
Shielding of nuclear reactor core is an important requirement of fast reactors. An important objective of future Fast Breeder Reactors (FBRs) is to reduce the volume of shields. A large number of materials have been considered for use to reduce the neutron flux to acceptable levels. A shield material which brings down the energy of neutrons by elastic and inelastic scattering along with absorption will be more effective. Ferro boron is identified as one of the advanced shielding materials considered for use in future FBRs, planned to be constructed in India. Ferroboron is an economical and indigenously available material which qualifies as a promising shield material through literature survey and scoping calculations. Experiments have been conducted in KAMINI reactor to understand the effectiveness of prospective shield material Ferro-boron as an in-core shield material for future FBRs. The Ferro boron used in these experiments contained 11.8% and 15% of boron. Precise determination of boron content in these ferro boron samples is very important to determine its effectiveness as a shield material. In this work a comparative study was carried out to determine the boron content in ferro boron samples. In the first method the sample was treated with incremental amounts of nitric acid under reflux (to prevent rigorous reaction and volatalisation of boron). The solution was gradually heated and the solution was filtered through a Whatman Filter paper no. 41. The undissolved ferro boron residue collected in the filter paper after filtration, is transferred to a platinum crucible; mixed with sodium carbonate and is ashed. The crucible is placed over a burner for 1 h to fuse the contents. The fused mass is leached in dilute hydrochloric acid, added to the nitric acid filtrate and made up to pre-determined volume
The Effect of Consolidation on TBM Shield Loading in Water-Bearing Squeezing Ground
Ramoni, M.; Anagnostou, G.
2011-01-01
Jamming or overstressing of the shield due to ground pressure are potential problems for tunnel boring machine (TBM) tunnelling in squeezing ground. The risk of shield jamming depends essentially on the deformation rate of the ground in the vicinity of the working face. The time-dependency of the ground response to the excavation is associated with its rheological properties as well as with the transient consolidation process that takes place around the opening in the case of a low-permeability saturated ground. The present paper focuses on the second mechanism and investigates the interaction between the advancing shield, tunnel lining and consolidating ground by means of transient numerical analyses. For a given set of geotechnical conditions and a given TBM configuration, the load exerted by the ground upon the shield during TBM operation decreases with increasing gross advance rate. During a long break in operations, the ground pressure may increase significantly, thereby necessitating a higher thrust force to overcome shield skin friction and restart the TBM. It is interesting to note that a high advance rate reduces the risk of shield jamming not only during TBM advance, but is also favourable with respect to any subsequent long standstills.
Parsa, Bita; Parsa, Parisa; Parsa, Nakisa
2016-10-01
Despite the importance of social organizational factors in career advancement and promotion among academic employees, still some academic employees suffer from low career advancement and consequently low academic performance. Aim of this study was to examine the mediation effect of self-efficacy on relationship between mentoring and career advancement among academic employees in the two public universities in Iran. This survey research was done among 307 randomly selected academic employees to determine predictors of their career advancement. Self-administered questionnaires were used to collect data. The Structural Equation Modelling (SEM) methodology was applied to determine the best fitted model to predict career advancement. Analysis of data was performed using the Pearson's correlation analysis and SEM. The results show that self-efficacy was related to mentoring and career advancement (pcareer advancement was significant (pcareer advancement (pcareer advancement.
Homogeneous versus heterogeneous shielding modeling of spent-fuel casks
International Nuclear Information System (INIS)
Carbajo, J.J.; Lindner, C.N.
1992-01-01
The design of spent-fuel casks for storage and transport requires modeling the cask for criticality, shielding, thermal, and structural analyses. While some parts of the cask are homogeneous, other regions are heterogeneous with different materials intermixed. For simplicity, some of the heterogeneous regions may be modeled as homogeneous. This paper evaluates the effect of homogenizing some regions of a cask on calculating radiation dose rates outside the cask. The dose rate calculations were performed with the one-dimensional discrete ordinates shielding XSDRNPM code coupled with the XSDOSE code and with the three-dimensional QAD-CGGP code. Dose rates were calculated radially at the midplane of the cask at two locations, cask surface and 2.3 m from the radial surface. The last location corresponds to a point 2 m from the lateral sides of a transport railroad car
Analysis of Shield Construction in Spherical Weathered Granite Development Area
Cao, Quan; Li, Peigang; Gong, Shuhua
2018-01-01
The distribution of spherical weathered bodies (commonly known as "boulder") in the granite development area directly affects the shield construction of urban rail transit engineering. This paper is based on the case of shield construction of granite globular development area in Southern China area, the parameter control in shield machine selection and shield advancing during the shield tunneling in this special geological environment is analyzed. And it is suggested that shield machine should be selected for shield construction of granite spherical weathered zone. Driving speed, cutter torque, shield machine thrust, the amount of penetration and the speed of the cutter head of shield machine should be controlled when driving the boulder formation, in order to achieve smooth excavation and reduce the disturbance to the formation.
The resonance self-shielding calculation with regularized random ladders
International Nuclear Information System (INIS)
Ribon, P.
1986-01-01
The straightforward method for calculation of resonance self-shielding is to generate one or several resonance ladders, and to process them as resolved resonances. The main drawback of Monte Carlo methods used to generate the ladders, is the difficulty of reducing the dispersion of data and results. Several methods are examined, and it is shown how one (a regularized sampling method) improves the accuracy. Analytical methods to compute the effective cross-section have recently appeared: they are basically exempt from dispersion, but are inevitably approximate. The accuracy of the most sophisticated one is checked. There is a neutron energy range which is improperly considered as statistical. An examination is presented of what happens when it is treated as statistical, and how it is possible to improve the accuracy of calculations in this range. To illustrate the results calculations have been performed in a simple case: nucleus 238 U, at 300 K, between 4250 and 4750 eV. (author)
RADSHI: shielding calculation program for different geometries sources
International Nuclear Information System (INIS)
Gelen, A.; Alvarez, I.; Lopez, H.; Manso, M.
1996-01-01
A computer code written in pascal language for IBM/Pc is described. The program calculates the optimum thickness of slab shield for different geometries sources. The Point Kernel Method is employed, which enables the obtention of the ionizing radiation flux density. The calculation takes into account the possibility of self-absorption in the source. The air kerma rate for gamma radiation is determined, and with the concept of attenuation length through the equivalent attenuation length the shield is obtained. The scattering and the exponential attenuation inside the shield material is considered in the program. The shield materials can be: concrete, water, iron or lead. It also calculates the shield for point isotropic neutron source, using as shield materials paraffin, concrete or water. (authors). 13 refs
Effects of drop testing on scale model shipping containers shielded with depleted uranium
International Nuclear Information System (INIS)
Butler, T.A.
1980-02-01
Three scale model shipping containers shielded with depleted uranium were dropped onto an essentially unyielding surface from various heights to determine their margins to failure. This report presents the results of a thorough posttest examination of the models to check for basic structural integrity, shielding integrity, and deformations. Because of unexpected behavior exhibited by the depleted uranium shielding, several tests were performed to further characterize its mechanical properties. Based on results of the investigations, recommendations are made for improved container design and for applying the results to full-scale containers. Even though the specimens incorporated specific design features, the results of this study are generally applicable to any container design using depleted uranium
Comparison of the CATHENA model of Gentilly-2 end shield cooling system predictions to station data
Energy Technology Data Exchange (ETDEWEB)
Zagre, G.; Sabourin, G. [Candu Energy Inc., Montreal, Quebec (Canada); Chapados, S. [Hydro-Quebec, Montreal, Quebec (Canada)
2012-07-01
As part of the Gentilly-2 Refurbishment Project, Hydro-Quebec has elected to perform the End Shield Cooling Safety Analysis. A CATHENA model of Gentilly-2 End Shield Cooling System was developed for this purpose. This model includes new elements compared to other CANDU6 End Shield Cooling models such as a detailed heat exchanger and control logic model. In order to test the model robustness and accuracy, the model predictions were compared with plant measurements.This paper summarizes this comparison between the model predictions and the station measurements. It is shown that the CATHENA model is flexible and accurate enough to predict station measurements for critical parameters, and the detailed heat exchanger model allows reproducing station transients. (author)
International Nuclear Information System (INIS)
Gonzalez, Dania Soguero; Ardanza, Armando Chavez
2013-01-01
This paper describes the process of installation of a self-shielded irradiator category I, model ISOGAMMA LL.Co of 60 Co, with a nominal 25 kCi activity, rate of absorbed dose 8 kG/h and 5 L workload. The stages are describe step by step: import, the customs procedure which included the interview with the master of the vessel transporter, the monitoring of the entire process by the head of radiological protection of the importing Center, control of the levels of surface contamination of the shipping container of the sources before the removal of the ship, the supervision of the national regulatory authority and the transportation to the final destination. Details of assembling of the installation and the opening of the container for transportation of supplies is outlined. The action plan previously developed for the case of occurrence of radiological successful events is presented, detailing the phase of the load of radioactive sources by the specialists of the company selling the facility (IZOTOP). Finally describes the setting and implementation of the installation and the procedure of licensing for exploitation
Weld metal microstructures of hardfacing deposits produced by self-shielded flux-cored arc welding
International Nuclear Information System (INIS)
Dumovic, M.; Monaghan, B.J.; Li, H.; Norrish, J.; Dunne, D.P.
2015-01-01
The molten pool weld produced during self-shielded flux-cored arc welding (SSFCAW) is protected from gas porosity arising from oxygen and nitrogen by reaction ('killing') of these gases by aluminium. However, residual Al can result in mixed micro-structures of δ-ferrite, martensite and bainite in hardfacing weld metals produced by SSFCAW and therefore, microstructural control can be an issue for hardfacing weld repair. The effect of the residual Al content on weld metal micro-structure has been examined using thermodynamic modeling and dilatometric analysis. It is concluded that the typical Al content of about 1 wt% promotes δ-ferrite formation at the expense of austenite and its martensitic/bainitic product phase(s), thereby compromising the wear resistance of the hardfacing deposit. This paper also demonstrates how the development of a Schaeffler-type diagram for predicting the weld metal micro-structure can provide guidance on weld filler metal design to produce the optimum microstructure for industrial hardfacing applications.
ICRF Faraday shield plasma sheath physics: The Perkins paradigm
International Nuclear Information System (INIS)
Whealton, J.H.; Ryan, P.M.; Raridon, R.J.
1989-01-01
Using a 2-D nonlinear formulation which considers the plasma edge near a Faraday shield in a self consistent manner, progress is indicated in the modeling of the ion motion for a Perkins embodiment. Ambiguities in the formulation are also indicated, the resolution of which will provide significant insight into the impurities generation for ICRH antennas. 6 refs., 3 figs
Some open questions concerning the neutral-shielding model of a fuelling pellet
International Nuclear Information System (INIS)
Chang, C.T.
1986-02-01
To obtain a better understanding of the implications and assumptions of the idealized neutral shielding model of Parks and Turnbull, the model is reformulated in a self consistent way. Due to the uncertainty of the actual ablation process occuring at the pellet surface, alternative boundary conditions are proposed. Their effect on the pellet ablation rate and the state of the ablated flow are examined by numerical analyses. The results show that the ablation rate is not sensitively affected but the ablatant state is markedly influenced by the boundary condition at the pellet surface. In particular, an increase of the energy flux received at the pellet surface by a factor of four hardly affect the ablation rate but changes the temperature and the density of the ablatant at the pellet surface by three orders of magnitude. Based on these obtained results, it is concluded that the idealized ablation model is adequate when pellet injection is used to fuel a plasma but requires modification when it is used to probe plasma properties and discharge conditions. (orig.)
An Entropy-Assisted Shielding Function in DDES Formulation for the SST Turbulence Model
Directory of Open Access Journals (Sweden)
Ling Zhou
2017-02-01
Full Text Available The intent of shielding functions in delayed detached-eddy simulation methods (DDES is to preserve the wall boundary layers as Reynolds-averaged Navier–Strokes (RANS mode, avoiding possible modeled stress depletion (MSD or even unphysical separation due to grid refinement. An entropy function fs is introduced to construct a DDES formulation for the k-ω shear stress transport (SST model, whose performance is extensively examined on a range of attached and separated flows (flat-plate flow, circular cylinder flow, and supersonic cavity-ramp flow. Two more forms of shielding functions are also included for comparison: one that uses the blending function F2 of SST, the other which adopts the recalibrated shielding function fd_cor of the DDES version based on the Spalart-Allmaras (SA model. In general, all of the shielding functions do not impair the vortex in fully separated flows. However, for flows including attached boundary layer, both F2 and the recalibrated fd_cor are found to be too conservative to resolve the unsteady flow content. On the other side, fs is proposed on the theory of energy dissipation and independent on from any particular turbulence model, showing the generic priority by properly balancing the need of reserving the RANS modeled regions for wall boundary layers and generating the unsteady turbulent structures in detached areas.
Bezshyiko, Iaroslava
2016-01-01
In the SHiP beam-dump of the order of 1011 muons will be produced per second. An active muon-shield is used to magnetically deflect these muons out of the acceptance of the spectrom- eter. This note describes how this shield is modelled and optimized. The SHiP spectrometer is being re-optimized using a conical decay-vessel, and utilizing the possibility to magnetize part of the beam-dump shielding iron. A shield adapted to these new conditions is presented which is significantly shorter and lighter than the shield used in the Technical Proposal (TP), while showing a similar performance.
Inverse Analysis and Modeling for Tunneling Thrust on Shield Machine
Directory of Open Access Journals (Sweden)
Qian Zhang
2013-01-01
Full Text Available With the rapid development of sensor and detection technologies, measured data analysis plays an increasingly important role in the design and control of heavy engineering equipment. The paper proposed a method for inverse analysis and modeling based on mass on-site measured data, in which dimensional analysis and data mining techniques were combined. The method was applied to the modeling of the tunneling thrust on shield machines and an explicit expression for thrust prediction was established. Combined with on-site data from a tunneling project in China, the inverse identification of model coefficients was carried out using the multiple regression method. The model residual was analyzed by statistical methods. By comparing the on-site data and the model predicted results in the other two projects with different tunneling conditions, the feasibility of the model was discussed. The work may provide a scientific basis for the rational design and control of shield tunneling machines and also a new way for mass on-site data analysis of complex engineering systems with nonlinear, multivariable, time-varying characteristics.
International Nuclear Information System (INIS)
Pelloni, S.; Cheng, E.T.
1985-02-01
The Swiss LOTUS fusion-fission hybrid test facility was used to investigate the influence of the self-shielding of resonance cross sections on the tritium breeding and on the thorium ratios. Nucleonic analyses were performed using the discrete-ordinates transport codes ANISN and ONEDANT, the surface-flux code SURCU, and the version 3 of the MCNP code for the Li 2 CO 3 and the Li 2 O blanket designs with lead, thorium and beryllium multipliers. Except for the MCNP calculation which bases on the ENDF/B-V files, all nuclear data are generated from the ENDF/B-IV basic library. For the deterministic methods three NJOY group libraries were considered. The first, a 39 neutron group self-shielded library, was generated at EIR. The second bases on the same group structure as the first does and consists of infinitely diluted cross sections. Finally the third library was processed at LANL and consists of coupled 30+12 neutron and gamma groups; these cross sections are not self-shielded. The Monte Carlo analysis bases on a continuous and on a discrete 262 group library from the ENDF/B-V evaluation. It is shown that the results agree well within 3% between the unshielded libraries and between the different transport codes and theories. The self-shielding of resonance cross sections results in a decrease of the thorium capture rate and in an increase of the tritium breeding of about 6%. The remaining computed ratios are not affected by the self-shielding of cross sections. (Auth.)
Support vector regression model for the estimation of γ-ray buildup factors for multi-layer shields
International Nuclear Information System (INIS)
Trontl, Kresimir; Smuc, Tomislav; Pevec, Dubravko
2007-01-01
The accuracy of the point-kernel method, which is a widely used practical tool for γ-ray shielding calculations, strongly depends on the quality and accuracy of buildup factors used in the calculations. Although, buildup factors for single-layer shields comprised of a single material are well known, calculation of buildup factors for stratified shields, each layer comprised of different material or a combination of materials, represent a complex physical problem. Recently, a new compact mathematical model for multi-layer shield buildup factor representation has been suggested for embedding into point-kernel codes thus replacing traditionally generated complex mathematical expressions. The new regression model is based on support vector machines learning technique, which is an extension of Statistical Learning Theory. The paper gives complete description of the novel methodology with results pertaining to realistic engineering multi-layer shielding geometries. The results based on support vector regression machine learning confirm that this approach provides a framework for general, accurate and computationally acceptable multi-layer buildup factor model
Modeling and characterization of shielded low loss CPWs on 65 nm node silicon
Energy Technology Data Exchange (ETDEWEB)
Wang Hongrui; Yang Dongxu; Zhang Li; Zhang Lei; Yu Zhiping, E-mail: hr-wang06@mails.tsinghua.edu.cn [Institute of Microelectronics, Tsinghua University, Beijing 100084 (China)
2011-06-15
Coplanar waveguides (CPWs) are promising candidates for high quality passive devices in millimeter-wave frequency bands. In this paper, CPW transmission lines with and without ground shields have been designed and fabricated on 65 nm CMOS technology. A physical-based model is proposed to describe the frequency-dependent per-unit-length L, C, R and G parameters. Starting with a basic CPW structure, the slow-wave effect and ground-shield influence have been analyzed and incorporated into the general model. The accuracy of the model is confirmed by experimental results. (semiconductor devices)
Modeling and characterization of shielded low loss CPWs on 65 nm node silicon
Hongrui, Wang; Dongxu, Yang; Li, Zhang; Lei, Zhang; Zhiping, Yu
2011-06-01
Coplanar waveguides (CPWs) are promising candidates for high quality passive devices in millimeter-wave frequency bands. In this paper, CPW transmission lines with and without ground shields have been designed and fabricated on 65 nm CMOS technology. A physical-based model is proposed to describe the frequency-dependent per-unit-length L, C, R and G parameters. Starting with a basic CPW structure, the slow-wave effect and ground-shield influence have been analyzed and incorporated into the general model. The accuracy of the model is confirmed by experimental results.
Modeling and characterization of shielded low loss CPWs on 65 nm node silicon
International Nuclear Information System (INIS)
Wang Hongrui; Yang Dongxu; Zhang Li; Zhang Lei; Yu Zhiping
2011-01-01
Coplanar waveguides (CPWs) are promising candidates for high quality passive devices in millimeter-wave frequency bands. In this paper, CPW transmission lines with and without ground shields have been designed and fabricated on 65 nm CMOS technology. A physical-based model is proposed to describe the frequency-dependent per-unit-length L, C, R and G parameters. Starting with a basic CPW structure, the slow-wave effect and ground-shield influence have been analyzed and incorporated into the general model. The accuracy of the model is confirmed by experimental results. (semiconductor devices)
Computed tomography shielding methods: a literature review.
Curtis, Jessica Ryann
2010-01-01
To investigate available shielding methods in an effort to further awareness and understanding of existing preventive measures related to patient exposure in computed tomography (CT) scanning. Searches were conducted to locate literature discussing the effectiveness of commercially available shields. Literature containing information regarding breast, gonad, eye and thyroid shielding was identified. Because of rapidly advancing technology, the selection of articles was limited to those published within the past 5 years. The selected studies were examined using the following topics as guidelines: the effectiveness of the shield (percentage of dose reduction), the shield's effect on image quality, arguments for or against its use (including practicality) and overall recommendation for its use in clinical practice. Only a limited number of studies have been performed on the use of shields for the eyes, thyroid and gonads, but the evidence shows an overall benefit to their use. Breast shielding has been the most studied shielding method, with consistent agreement throughout the literature on its effectiveness at reducing radiation dose. The effect of shielding on image quality was not remarkable in a majority of studies. Although it is noted that more studies need to be conducted regarding the impact on image quality, the currently published literature stresses the importance of shielding in reducing dose. Commercially available shields for the breast, thyroid, eyes and gonads should be implemented in clinical practice. Further research is needed to ascertain the prevalence of shielding in the clinical setting.
Douine, Maylis; Sanna, Alice; Galindo, Muriel; Musset, Lise; Pommier de Santi, Vincent; Marchesini, Paola; Magalhaes, Edgard Dias; Suarez-Mutis, Martha; Hiwat, Helene; Nacher, Mathieu; Vreden, Stephen; Garancher, Laure
2018-04-10
Illegal gold miners in French Guiana, a French overseas territory ('département') located in Amazonia, often carry malaria parasites (up to 46.8%). While the Guiana Shield Region aims at malaria elimination, the high prevalence of Plasmodium in this hard-to-reach population in conjunction with frequent incorrect use of artemisinin-based anti-malarials could favour the emergence of resistant parasites. Due to geographical and regulatory issues in French Guiana, usual malaria control strategies cannot be implemented in this particular context. Therefore, new strategies targeting this specific population in the forest are required. Numerous discussions among health institutions and scientific partners from French Guiana, Brazil and Suriname have led to an innovative project based on the distribution of kits for self-diagnosis and self-treatment of Plasmodium infections. The kit-distribution will be implemented at "resting sites", which are areas across the border of French Guiana regularly frequented by gold miners. The main objective is to increase the appropriate use and complete malaria treatment after a positive malaria diagnosis with a rapid test, which will be evaluated with before-and-after cross-sectional studies. Monitoring indicators will be collected from health mediators at the time of kit distribution and during subsequent visits, and from illegal gold miners themselves, through a smartphone application. The project funding is multisource, including Ministries of Health of the three countries, WHO/PAHO, and the European Union. This project will start in April 2018 as a 18 month pilot study led by the Clinical Investigation Centre of Cayenne. Results should be available at the end of 2019. This innovative approach may have several limitations which should be taken into account, as potential side effects, kit misuse or resale, declarative main criteria, or no Plasmodium vivax curative treatment. Close monitoring is thus needed. This project may be the
International Nuclear Information System (INIS)
Chiba, Go; Tsuji, Masashi; Narabayashi, Tadashi
2014-01-01
In order to properly quantify fission reactor neutronics parameter uncertainties, we have to use covariance data and sensitivity profiles consistently. In the present paper, we establish two consistent methodologies for uncertainty quantification: a self-shielded cross section-based consistent methodology and an infinitely-diluted cross section-based consistent methodology. With these methodologies and the covariance data of uranium-238 nuclear data given in JENDL-3.3, we quantify uncertainties of infinite neutron multiplication factors of light water reactor and fast reactor fuel cells. While an inconsistent methodology gives results which depend on the energy group structure of neutron flux and neutron-nuclide reaction cross section representation, both the consistent methodologies give fair results with no such dependences.
Multifunctional BHL Radiation Shield, Phase I
National Aeronautics and Space Administration — Advances in radiation shielding technology remain an important challenge for NASA in order to protect their astronauts, particularly as NASA grows closer to manned...
Status of reactor-shielding research in the US
International Nuclear Information System (INIS)
Maienshein, F.C.
1980-01-01
While reactor programs change, shielding analysis methods are improved slowly. Version-V of ENDF/B provides improved data and Version-VI will be cost effective in advanced fission reactors are to be developed in the US. Benchmarks for data and methods validation are collected and distributed in the US in two series, one primarily for FBR-related experiments and one for LWR calculational methods. For LWR design, cavity streaming is now handled adequately, if with varying degrees of elegance. Investigations of improved detector response for LWRs rely upon transport methods. The great potential importance of pressure-vessel damage is dreflected in widespread studies to aid in the prediction of neutron fluences in vessels. For LMFBRS, the FFTF should give attenuation results on an operating reactor. For larger power reactors, the advantages of alternate shield materials appear compelling. A few other shielding studies appear to require experimental confirmation if LMFBRs are to be economically competitive. A coherent shielding program for the GCFR is nearing completion. For the fusion-reactor program, methods verification is under way, practical calculations are well advanced for test devices such as the TFTR and FMIT, and consideration is now given to shielding problems of large reactors, as in the ETF study
International Nuclear Information System (INIS)
Ganesan, S.
1978-01-01
A set of energy dependent fission widths of 1 + spin state corresponding to the recommended fission cross sections of Sowerby et al is evaluated by adjustment in the energy region 600 ev to 25 Kev. Corresponding to these mean fission widths of 1 + spin state, the intermediate resonance parameters based on Weigmann's formulation of Struitinsky's double humped fission barrier model are then obtained. Pseudorandom resonances are generated with and without the intermediate structure in the mean fission but leading to the same value of infinite dilution fission cross section. The effect of the intermediate structure on the self shielding factors was then investigated. (author)
Neutron shielding material based on colemanite and epoxy resin
International Nuclear Information System (INIS)
Okuno, K.
2005-01-01
In recent years, there has been a need for compact shielding design such as self-shielding of a PET cyclotron or up-gradation of radiation machinery in existing facilities. In these cases, high performance shielding materials are needed. Concrete or polyethylene have been used for a neutron shield. However, for compact shielding, they fall short in terms of performance or durability. Therefore, a new type of neutron shielding material based on epoxy resin and colemanite has been developed. Slab attenuation experiments up to 40 cm for the new shielding material were carried out using a 252 Cf neutron source. Measurement was carried out using a REM-counter, and compared with calculation. The results show that the shielding performance is better than concrete and polyethylene mixed with 10 wt% boron oxide. From the result, we confirmed that the performance of the new material is suitable for practical use. (authors)
International Nuclear Information System (INIS)
Suzuki, Shigenori; Iimori, Hiroshi; Kobori, Junzo.
1980-01-01
Purpose: To provide a neutron shielding material which incorporates preferable shielding capacity, heat resistance, fire resistance and workability by employing a mixture of thermosetting resin, polyethylene and aluminium hydroxide in special range ratio and curing it. Constitution: A mixture containing 20 to 60% by weight of thermosetting resin having preferable heat resistance, 10 to 40% by weight of polyethylene powder having high hydrogen atom density and 1000 to 60000 of molecular weight, and 15 to 55% by weight of Al(OH) 3 for imparting fire resistance and self-fire extinguishing property thereto is cured. At this time approx. 0.5 to 5% of curing catalyst of the thermosetting resin is contained in 100 parts by weight of the mixture. (Sekiya, K.)
Graphs of neutron cross sections in JSD1000 for radiation shielding safety analysis
International Nuclear Information System (INIS)
Yamano, Naoki
1984-03-01
Graphs of neutron cross sections and self-shielding factors in the JSD1000 library are presented for radiation shielding safety analysis. The compilation contains various reaction cross sections for 42 nuclides from 1 H to 241 Am in the energy range from 3.51 x 10 -4 eV to 16.5 MeV. The Bondarenko-type self-shielding factors of each reaction are given by the background cross sections from σ 0 = 0 to σ 0 = 10000. (author)
Shielding structure analysis for LSDS facility
Energy Technology Data Exchange (ETDEWEB)
Choi, Hong Yeop; Kim, Jeong Dong; Lee, Yong Deok; Kim, Ho Dong [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)
2014-05-15
The nuclear material (Pyro, Spent nuclear fuel) itself and the target material to generate neutrons is the LSDS system for isotopic fissile assay release of high intensity neutron and gamma rays. This research was performed to shield from various strong radiation. A shielding evaluation was carried out with a facilities model of LSDS system. The MCNPX 2.5 code was used and a shielding evaluation was performed for the shielding structure and location. The radiation dose based on the hole structure and location of the wall was evaluated. The shielding evaluation was performed to satisfy the safety standard for a normal person (1 μSv/h) and to use enough interior space. The MCNPX2.5 code was used and a dose evaluation was performed for the location of the shielding material, shielding structure, and hole structure. The evaluation result differs according to the shielding material location. The dose rate was small when the shielding material was positioned at the center. The dose evaluation result regarding the location of the shielding material was applied to the facility and the shielding thickness was determined (In 50 cm + Borax 5 cm + Out 45cm). In the existing hole structure, the radiation leak is higher than the standard. A hole structure model to prevent leakage of radiation was proposed. The general public dose limit was satisfied when using the concrete reinforcement and a zigzag structure. The shielding result will be of help to the facility shielding optimization.
Shielding structure analysis for LSDS facility
International Nuclear Information System (INIS)
Choi, Hong Yeop; Kim, Jeong Dong; Lee, Yong Deok; Kim, Ho Dong
2014-01-01
The nuclear material (Pyro, Spent nuclear fuel) itself and the target material to generate neutrons is the LSDS system for isotopic fissile assay release of high intensity neutron and gamma rays. This research was performed to shield from various strong radiation. A shielding evaluation was carried out with a facilities model of LSDS system. The MCNPX 2.5 code was used and a shielding evaluation was performed for the shielding structure and location. The radiation dose based on the hole structure and location of the wall was evaluated. The shielding evaluation was performed to satisfy the safety standard for a normal person (1 μSv/h) and to use enough interior space. The MCNPX2.5 code was used and a dose evaluation was performed for the location of the shielding material, shielding structure, and hole structure. The evaluation result differs according to the shielding material location. The dose rate was small when the shielding material was positioned at the center. The dose evaluation result regarding the location of the shielding material was applied to the facility and the shielding thickness was determined (In 50 cm + Borax 5 cm + Out 45cm). In the existing hole structure, the radiation leak is higher than the standard. A hole structure model to prevent leakage of radiation was proposed. The general public dose limit was satisfied when using the concrete reinforcement and a zigzag structure. The shielding result will be of help to the facility shielding optimization
Church, Cody; Mawko, George; Archambault, John Paul; Lewandowski, Robert; Liu, David; Kehoe, Sharon; Boyd, Daniel; Abraham, Robert; Syme, Alasdair
2018-02-01
Radiopaque microspheres may provide intraprocedural and postprocedural feedback during transarterial radioembolization (TARE). Furthermore, the potential to use higher resolution x-ray imaging techniques as opposed to nuclear medicine imaging suggests that significant improvements in the accuracy and precision of radiation dosimetry calculations could be realized for this type of therapy. This study investigates the absorbed dose kernel for novel radiopaque microspheres including contributions of both short and long-lived contaminant radionuclides while concurrently quantifying the self-shielding of the glass network. Monte Carlo simulations using EGSnrc were performed to determine the dose kernels for all monoenergetic electron emissions and all beta spectra for radionuclides reported in a neutron activation study of the microspheres. Simulations were benchmarked against an accepted 90 Y dose point kernel. Self-shielding was quantified for the microspheres by simulating an isotropically emitting, uniformly distributed source, in glass and in water. The ratio of the absorbed doses was scored as a function of distance from a microsphere. The absorbed dose kernel for the microspheres was calculated for (a) two bead formulations following (b) two different durations of neutron activation, at (c) various time points following activation. Self-shielding varies with time postremoval from the reactor. At early time points, it is less pronounced due to the higher energies of the emissions. It is on the order of 0.4-2.8% at a radial distance of 5.43 mm with increased size from 10 to 50 μm in diameter during the time that the microspheres would be administered to a patient. At long time points, self-shielding is more pronounced and can reach values in excess of 20% near the end of the range of the emissions. Absorbed dose kernels for 90 Y, 90m Y, 85m Sr, 85 Sr, 87m Sr, 89 Sr, 70 Ga, 72 Ga, and 31 Si are presented and used to determine an overall kernel for the
Directory of Open Access Journals (Sweden)
GO CHIBA
2014-06-01
Full Text Available In order to properly quantify fission reactor neutronics parameter uncertainties, we have to use covariance data and sensitivity profiles consistently. In the present paper, we establish two consistent methodologies for uncertainty quantification: a self-shielded cross section-based consistent methodology and an infinitely-diluted cross section-based consistent methodology. With these methodologies and the covariance data of uranium-238 nuclear data given in JENDL-3.3, we quantify uncertainties of infinite neutron multiplication factors of light water reactor and fast reactor fuel cells. While an inconsistent methodology gives results which depend on the energy group structure of neutron flux and neutron-nuclide reaction cross section representation, both the consistent methodologies give fair results with no such dependences.
Shielded transient self-interaction of a bunch entering a circle from a straight path
International Nuclear Information System (INIS)
Li, R.; Bohn, C.L.; Bisognano, J.J.
1997-01-01
When a short (mm-length) bunch with high (nC-regime) charge is transported through a magnetic bending system, self-interaction via coherent synchrotron radiation (CSR) and space charge may alter the bunch dynamics significantly. The authors consider a Gaussian rigid-line-charge bunch following a straight-path trajectory into a circle, with the trajectory centered between two infinite, parallel, perfectly conducting plates. Transients associated with CSR and space charge generated from source particles both on the straight path and the circle are calculated, and their net effect on the radiated power is contrasted with that of shielded steady-state CSR
Deep-penetration calculations in concrete and iron for shielding of proton therapy accelerators
International Nuclear Information System (INIS)
Sheu, Rong-Jiun; Chen, Yen-Fu; Lin, Uei-Tyng; Jiang, Shiang-Huei
2012-01-01
Proton accelerators in the energy range of approximately 200 MeV have become increasingly popular for cancer treatment in recent years. These proton therapy facilities usually involve bulky concrete or iron in their shielding design or accelerator structure. Simple shielding data, such as source terms or attenuation lengths for various proton energies and materials are useful in designing accelerator shielding. Understanding the appropriateness or uncertainties associated with these data, which are largely generated from Monte Carlo simulations, is critical to the quality of a shielding design. This study demonstrated and investigated the problems of deep-penetration calculations on the estimation of shielding parameters through an extensive comparison between the FLUKA and MCNPX calculations for shielding against a 200-MeV proton beam hitting an iron target. Simulations of double-differential neutron production from proton bombardment were validated by comparison with experimental data. For the concrete shielding, the FLUKA calculated depth–dose distributions were consistent with the MCNPX results, except for some discrepancies in backward directions. However, for the iron shielding, if FLUKA is used inappropriately then overestimation of neutron attenuation can be expected as shown by this work because of the multigroup treatment for low-energy neutrons in FLUKA. Two neutron energy group structures, three degrees of self-shielding correction, and two iron compositions were considered in this study. Significant variation of the resulting attenuation lengths indicated the importance of problem-dependent multigroup cross sections and proper modeling of iron composition in deep-penetration calculations.
[Qualitative research of self-management behavior in patients with advanced schistosomiasis].
Wang, Jian-ping; Wang, Xing-ju; Bao, Hui-hong; Zhang, Hong; Xu, Zheng-rong
2013-10-01
To explore the self-management behavior of patients with advanced schistosomiasis, so as to provide the evidence for improving clinical nursing. A total of 18 patients with advanced schistosomiasis were interviewed in depth by using a semi structured interview method. The results were analyzed with Miles and Huberman content analysis method. Most of the patients with advanced schistosomiasis had self-management control behavior and were cooperated with medical assistance because of their seriously illness. Based on data analysis, the symptom management, follow-up management, a healthy lifestyle, medication awareness, and emotional management were obtained. The patients with advanced schistosomiasis have self management control behavior. Health care workers should promote the patients, their families and social people to participate in the self-management behavior of advanced schistosomiasis patients.
Successful public-private partnerships: The NYPD shield model.
Amadeo, Vincent; Iannone, Stephen
2017-12-01
This article will identify the challenges that post 9/11 law enforcement faces regarding privatepublic partnerships and describe in detail the NYPD Shield programme, created to combat those challenges. Recommendations made by the 911 Commission included the incorporation of the private sector into future homeland security strategies. One such strategy is NYPD Shield. This programme is a nationally recognized award-winning public-private partnership dedicated to providing counterterrorism training and information sharing with government agencies, non-government organizations, private businesses, and the community. Information is shared through several platforms that include a dedicated website, instruction of counterterrorism training curricula, e-mail alerts, intelligence assessments and the hosting of quarterly conferences. This article also details how the NYPD Shield is providing its successful template to other law enforcement agencies enabling them to initiate similar programmes in their respective jurisdictions, and in doing so joining a National Shield Network.
A Brief History of Meteoroid and Orbital Debris Shielding Technology for US Manned Spacecraft
Bjorkman, Michael D.; Hyde, James L.
2008-01-01
Meteoroid and orbital debris shielding has played an important role from the beginning of manned spaceflight. During the early 60 s, meteoroid protection drove requirements for new meteor and micrometeoroid impact science. Meteoroid protection also stimulated advances in the technology of hypervelocity impact launchers and impact damage assessment methodologies. The first phase of meteoroid shielding assessments closed in the early 70 s with the end of the Apollo program. The second phase of meteoroid protection technology began in the early 80 s when it was determined that there is a manmade Earth orbital debris belt that poses a significant risk to LEO manned spacecraft. The severity of the Earth orbital debris environment has dictated changes in Space Shuttle and ISS operations as well as driven advances in shielding technology and assessment methodologies. A timeline of shielding technology and assessment methodology advances is presented along with a summary of risk assessment results.
Innovative technologies for Faraday shield cooling
International Nuclear Information System (INIS)
Rosenfeld, J.H.; Lindemuth, J.E.; North, M.T.; Goulding, R.H.
1995-01-01
Alternative advanced technologies are being evaluated for use in cooling the Faraday shields used for protection of ion cyclotron range of frequencies (ICR) antennae in Tokamaks. Two approaches currently under evaluation include heat pipe cooling and gas cooling. A Monel/water heat pipe cooled Faraday shield has been successfully demonstrated. Heat pipe cooling offers the advantage of reducing the amount of water discharged into the Tokamak in the event of a tube weld failure. The device was recently tested on an antenna at Oak Ridge National Laboratory. The heat pipe design uses inclined water heat pipes with warm water condensers located outside of the plasma chamber. This approach can passively remove absorbed heat fluxes in excess of 200 W/cm 2 ;. Helium-cooled Faraday shields are also being evaluated. This approach offers the advantage of no liquid discharge into the Tokamak in the event of a tube failure. Innovative internal cooling structures based on porous metal cooling are being used to develop a helium-cooled Faraday shield structure. This approach can dissipate the high heat fluxes typical of Faraday shield applications while minimizing the required helium blower power. Preliminary analysis shows that nominal helium flow and pressure drop can sufficiently cool a Faraday shield in typical applications. Plans are in progress to fabricate and test prototype hardware based on this approach
Survivor shielding. Part A. Nagasaki factory worker shielding
International Nuclear Information System (INIS)
Santoro, Robert T.; Barnes, John M.; Azmy, Yousry Y.; Kerr, George D.; Egbert, Stephen D.; Cullings, Harry M.
2005-01-01
Recent investigations based on conventional chromosome aberration data by the RERF suggest that the DS86 doses received by many Nagasaki factory workers may have been overestimated by as much as 40% relative to those for other survivors in Japanese-type houses and other shielding configurations (Kodama et al. 2001). Since the factory workers represent about 25% of the Nagasaki survivors with DS86 doses in excess of 0.5 Gy (50 rad), systematic errors in their dose estimates can have a major impact on the risk coefficients from RERF studies. The factory worker doses may have been overestimated for a number of reasons. The calculation techniques, including the factory building modeling, weapon source spectra and cross-section data used in the DS86 shielding calculations were not detailed enough to replicate actual conditions. The models used did not take into account local shielding provided by machinery, tools, and the internal structure in the buildings. In addition, changes in the disposition of shielding following collapse of the building by the blast wave were not considered. The location of large factory complexes may be uncertain, causing large numbers of factory survivors, correctly located relative to each other, to be uniformly too close to the hypocenter. Any or all of these reasons are sufficient to result in an overestimate of the factory worker doses. During the DS02 studies, factory worker doses have been reassessed by more carefully modeling the factory buildings, incorporating improved radiation transport methods and cross-section data and using the most recent bomb leakage spectra (Chapter 2). Two-dimensional discrete ordinates calculations were carried out initially to estimate the effects of workbenches and tools on worker doses to determine if the inclusion of these components would, in fact, reduce the dose by amounts consistent with the RERF observations (Kodama et al. 2001). (author)
International Nuclear Information System (INIS)
Marques, Andre Luis Ferreira; Ting, Daniel Kao Sun; Mendonca, Arlindo Gilson
1996-01-01
A calculation methodology of Flux Depression, Self-Shielding and Cadmium Factors is presented, using the ANISN code, for experiments conducted at the IPEN/MB-01 Research Reactor. The correction factors were determined considering thermal neutron flux and 0.125 e 0.250 mm diameter of 197 Au wires. (author)
Shielded transient self-interaction of a bunch entering a circle from a straight path
International Nuclear Information System (INIS)
Li, R.; Bohn, C.L.; Bisognano, J.J.
1997-01-01
Recent developments in electron-gun and injector technologies enable production of short (mm-length), high-charge (nC-regime) bunches. In this parameter regime, the curvature effect on the bunch self-interaction, by way of coherent synchrotron radiation (CSR) and space-charge forces as the beam traverses magnet bends, may cause serious emittance degradation. In this paper, the authors study an electron bunch orbiting between two infinite, parallel conducting plates. The bunch moves on a trajectory from a straight path to a circular orbit and begins radiating. Transient effects, arising from CSR and space-charge forces generated from source particles both on the bend and on the straight path prior to the bend, are analyzed using Lienard-Wiechert fields, and their overall net effect is obtained. The influence of the plates on the transients is contrasted to their shielding of the steady-state radiated power. Results for emittance degradation induced by this self-interaction are also presented
International Nuclear Information System (INIS)
Frankle, S.C.; Fitzgerald, D.H.; Hutson, R.L.; Macek, R.J.; Wilkinson, C.A.
1993-01-01
Neutron dose equivalent rates have been measured for 800-MeV proton beam spills at the Los Alamos Meson Physics Facility. Neutron detectors were used to measure the neutron dose levels at a number of locations for each beam-spill test, and neutron energy spectra were measured for several beam-spill tests. Estimates of expected levels for various detector locations were made using a simple analytical model developed for 800-MeV proton beam spills. A comparison of measurements and model estimates indicates that the model is reasonably accurate in estimating the neutron dose equivalent rate for simple shielding geometries. The model fails for more complicated shielding geometries, where indirect contributions to the dose equivalent rate can dominate
Resonance self-shielding methodology of new neutron transport code STREAM
International Nuclear Information System (INIS)
Choi, Sooyoung; Lee, Hyunsuk; Lee, Deokjung; Hong, Ser Gi
2015-01-01
This paper reports on the development and verification of three new resonance self-shielding methods. The verifications were performed using the new neutron transport code, STREAM. The new methodologies encompass the extension of energy range for resonance treatment, the development of optimum rational approximation, and the application of resonance treatment to isotopes in the cladding region. (1) The extended resonance energy range treatment has been developed to treat the resonances below 4 eV of three resonance isotopes and shows significant improvements in the accuracy of effective cross sections (XSs) in that energy range. (2) The optimum rational approximation can eliminate the geometric limitations of the conventional approach of equivalence theory and can also improve the accuracy of fuel escape probability. (3) The cladding resonance treatment method makes it possible to treat resonances in cladding material which have not been treated explicitly in the conventional methods. These three new methods have been implemented in the new lattice physics code STREAM and the improvement in the accuracy of effective XSs is demonstrated through detailed verification calculations. (author)
Double-layer neutron shield design as neutron shielding application
Sariyer, Demet; Küçer, Rahmi
2018-02-01
The shield design in particle accelerators and other high energy facilities are mainly connected to the high-energy neutrons. The deep penetration of neutrons through massive shield has become a very serious problem. For shielding to be efficient, most of these neutrons should be confined to the shielding volume. If the interior space will become limited, the sufficient thickness of multilayer shield must be used. Concrete and iron are widely used as a multilayer shield material. Two layers shield material was selected to guarantee radiation safety outside of the shield against neutrons generated in the interaction of the different proton energies. One of them was one meter of concrete, the other was iron-contained material (FeB, Fe2B and stainless-steel) to be determined shield thicknesses. FLUKA Monte Carlo code was used for shield design geometry and required neutron dose distributions. The resulting two layered shields are shown better performance than single used concrete, thus the shield design could leave more space in the interior shielded areas.
Directory of Open Access Journals (Sweden)
Zeng Huilin
2014-10-01
Full Text Available In order to realize the automatic welding of pipes in a complex operation environment, an automatic welding system has been developed by use of all-position self-shielded flux cored wires due to their advantages, such as all-position weldability, good detachability, arc's stability, low incomplete fusion, no need for welding protective gas or protection against wind when the wind speed is < 8 m/s. This system consists of a welding carrier, a guide rail, an auto-control system, a welding source, a wire feeder, and so on. Welding experiments with this system were performed on the X-80 pipeline steel to determine proper welding parameters. The welding technique comprises root welding, filling welding and cover welding and their welding parameters were obtained from experimental analysis. On this basis, the mechanical properties tests were carried out on welded joints in this case. Results show that this system can help improve the continuity and stability of the whole welding process and the welded joints' inherent quality, appearance shape, and mechanical performance can all meet the welding criteria for X-80 pipeline steel; with no need for windbreak fences, the overall welding cost will be sharply reduced. Meanwhile, more positive proposals were presented herein for the further research and development of this self-shielded flux core wires.
Influence of preheating on API 5L-X80 pipeline joint welding with self shielded flux-cored wire
International Nuclear Information System (INIS)
Cooper, R.; Silva, J. H. F.; Trevisan, R. E.
2004-01-01
The present work refers to the characterization of API 5L-X80 pipeline joints welded with self-shielded flux cored wire. This process was evaluated under preheating conditions, with an uniform and steady heat input. All joints were welded in flat position (1G), with the pipe turning and the torch still. Tube dimensions were 762 mm in external diameter and 16 mm in thickness. Welds were applied on single V-groove, with six weld beads, along with three levels of preheating temperatures (room temperature, 100 degree centigree, 160 degree centigree). These temperatures were maintained as inter pass temperature. The filler metal E71T8-K6 with mechanical properties different from parent metal was used in under matched conditions. The weld characterization is presented according to the mechanical test results of tensile strength, hardness and impact test. The mechanical tests were conducted according to API 1104, AWS and ASTM standards. API 1104 and API 51 were used as screening criteria. According to the results obtained, it was possible to remark that it is appropriate to weld API 5L-X80 steel ducts with Self-shielded Flux Cored wires, in conformance to the API standards and no preheat temperature is necessary. (Author) 22 refs
Optimal selection for shielding materials by fuzzy linear programming
International Nuclear Information System (INIS)
Kanai, Y.; Miura, N.; Sugasawa, S.
1996-01-01
An application of fuzzy linear programming methods to optimization of a radiation shield is presented. The main purpose of the present study is the choice of materials and the search of the ratio of mixture-component as the first stage of the methodology on optimum shielding design according to individual requirements of nuclear reactor, reprocessing facility, shipping cask installing spent fuel, ect. The characteristic values for the shield optimization may be considered their cost, spatial space, weight and some shielding qualities such as activation rate and total dose rate for neutron and gamma ray (includes secondary gamma ray). This new approach can reduce huge combination calculations for conventional two-valued logic approaches to representative single shielding calculation by group-wised optimization parameters determined in advance. Using the fuzzy linear programming method, possibilities for reducing radiation effects attainable in optimal compositions hydrated, lead- and boron-contained materials are investigated
Ladner, D. R.; Martinez-Galarce, D. S.; McCammon, D.
2006-04-01
An X-ray detection instrument to be flown on a sounding rocket experiment (the Advanced Technology Solar Spectroscopic Imager - ATSSI) for solar physics observations is being developed by the Lockheed Martin Solar and Astrophysics Laboratory (LMSAL). The detector is a novel class of microcalorimeter, a superconducting Transition-Edge Sensor (TES), that coupled with associated SQUID and feedback electronics requires high temperature stability at ~70 mK to resolve the energy of absorbed X-ray photons emitted from the solar corona. The cooling system incorporates an existing Adiabatic Demagnetization Refrigerator (ADR) developed at the University of Wisconsin (UW), which was previously flown to study the diffuse cosmic X-ray background. The Si thermistor detectors for that project required 130 K shielded JFET electronic components that are much less sensitive to the external field of the ADR solenoid than are the 1st (~70 mK) and 2nd (~2 K) SQUID stages used with TESs for solar observations. Modification of the Wisconsin ADR design, including TES focal plane and electronics re-positioning, therefore requires a tradeoff between the existing ADR solenoid nulling coil geometry and a low mass passive solenoid shield, while preserving the vibration isolation features of the existing design. We have developed models to accurately compute the magnetic field with and without shielding or nulling coils at critical locations to guide the re-design of the detector subsystem. The models and their application are described.
Thick Galactic Cosmic Radiation Shielding Using Atmospheric Data
Youngquist, Robert C.; Nurge, Mark A.; Starr, Stanley O.; Koontz, Steven L.
2013-01-01
NASA is concerned with protecting astronauts from the effects of galactic cosmic radiation and has expended substantial effort in the development of computer models to predict the shielding obtained from various materials. However, these models were only developed for shields up to about 120 g!cm2 in thickness and have predicted that shields of this thickness are insufficient to provide adequate protection for extended deep space flights. Consequently, effort is underway to extend the range of these models to thicker shields and experimental data is required to help confirm the resulting code. In this paper empirically obtained effective dose measurements from aircraft flights in the atmosphere are used to obtain the radiation shielding function of the earth's atmosphere, a very thick shield. Obtaining this result required solving an inverse problem and the method for solving it is presented. The results are shown to be in agreement with current code in the ranges where they overlap. These results are then checked and used to predict the radiation dosage under thick shields such as planetary regolith and the atmosphere of Venus.
Evaluation of the room shielding thickness of Hi-Art tomotherapy system
International Nuclear Information System (INIS)
Liu Haikuan; Wu Jinhai; Gu Naigu; Gao Yiming; Wang Li; Huang Weiqin; Wang Fengxian
2010-01-01
In this paper, we calculate and evaluate the room shielding thickness of a Hi-Art tomotherapy system, which is a new type of radiotherapy facility. Due to the self-shielding of the accelerator,only scattered beam and beam leakage were considered in calculating the room shielding thickness. The radiation field of the tomotherapy system was used as the basic data to calculate the shielding thickness of every 15 degree solid angle. The maximum shielding thickness required of each shielding wall was at the position with the angle of 15 degree, and the calculated shielding thickness were 1023, 975, 917, 1460, 1147 and 1189 mm for the east wall,south wall,west wall, north wall, the roof and the floor,respectively. According to the calculation results, all shielding walls, ceiling and floor could meet the requirement of the radiation protection, but the north wall thickness of 1200 mm was a little thinner. (authors)
International Nuclear Information System (INIS)
Sauermann, P.F.
1985-08-01
The basis of shielding practice against external irradiation is shown in a simple way. For most sources of radiation (point sources) occurring in shielding practice, the basic data are given, mainly in the form of tables, which are required to solve the shielding problems. The application of these data is explained and discussed using practical examples. Thickness of shielding panes of glove boxes for α and β radiation; shielding of sealed γ-radiography sources; shielding of a Co-60 radiation source, and of the manipulator panels for hot cells; damping factors for γ radiation and neutrons; shielding of fast and thermal neutrons, and of bremsstrahlung (X-ray tubes, Kr-85 pressure gas cylinders, 42 MeV betatrons, 20 MeV linacs); two-fold shielding (lead glass windows for hot cells, 14 MeV neutron generators); shielding against scattered radiation. (orig./HP) [de
Energy Technology Data Exchange (ETDEWEB)
Tunes, M.A., E-mail: matheus.tunes@usp.br [Department of Metallurgical and Materials Engineering, Escola Politécnica da Universidade de São Paulo, Av. Prof. Mello Moraes, 2463 – CEP 05508 – 030 São Paulo (Brazil); Oliveira, C.R.E. de, E-mail: cassiano@unm.edu [Department of Nuclear Engineering, The University of New Mexico, Farris Engineering Center, 221, Albuquerque, NM 87131-1070 (United States); Schön, C.G., E-mail: schoen@usp.br [Department of Metallurgical and Materials Engineering, Escola Politécnica da Universidade de São Paulo, Av. Prof. Mello Moraes, 2463 – CEP 05508 – 030 São Paulo (Brazil)
2017-03-15
Highlights: • Use of two n-γ transport codes leads to optimized model of compact nuclear reactor. • It was possible to safely reduce both weight and volume of the biological shielding. • Best configuration obtained by using new composites for both γ and n attenuation. - Abstract: The aim of the present work is to develop a computational model of a compact pressurized water nuclear reactor (PWR) to investigate the use of innovative materials to enhance the biological shielding effectiveness. Two radiation transport codes were used: the first one – MCNP – for the PWR design and the GEM/EVENT to simulate (in a 1D slab) the behavior of several materials and shielding thickness on gamma and neutron radiation. Additionally MATLAB Optimization Toolbox was used to provide new geometric configurations of the slab aiming at reducing the volume and weight of the walls by means of a cost/objective function. It is demonstrated in the reactor model that the dose rate outside biological shielding has been reduced by one order of magnitude for the optimized model compared with the initial configuration. Volume and weight of the shielding walls were also reduced. The results indicated that one-dimensional deterministic code to reach an optimized geometry and test materials, combined with a three-dimensional model of a compact nuclear reactor in a stochastic code, is a fast and efficient procedure to test shielding performance and optimization before the experimental assessment. A major outcome of this research is that composite materials (ECOMASS 2150TU96) may replace (with advantages) traditional shielding materials without jeopardizing the nuclear power plant safety assurance.
Anisotropic Pressure, Transport, and Shielding of Magnetic Perturbations
International Nuclear Information System (INIS)
Mynick, H.E.; Boozer, A.H.
2008-01-01
We compute the effect on a tokamak of applying a nonaxisymmetric magnetic perturbation (delta)B. An equilibrium with scalar pressure p yields zero net radial current, and therefore zero torque. Thus, the usual approach, which assumes scalar pressure, is not self-consistent, and masks the close connection which exists between that radial current and the in-surface currents, which provide shielding or amplification of (delta)B. Here, we analytically compute the pressure anisotropy, anisotropy, p # parallel#, p # perpendicular# and ≠ p, and from this, both the radial and in-surface currents. The surface-average of the radial current recovers earlier expressions for ripple transport, while the in-surface currents provide an expression for the amount of self-consistent shielding the plasma provides.
Development of neutron shielding material for cask
International Nuclear Information System (INIS)
Najima, K.; Ohta, H.; Ishihara, N.; Matsuoka, T.; Kuri, S.; Ohsono, K.; Hode, S.
2001-01-01
Since 1980's Mitsubishi Heavy Industries, Ltd (MHI) has established transport and storage cask design 'MSF series' which makes higher payload and reliability for long term storage. MSF series transport and storage cask uses new-developed neutron shielding material. This neutron shielding material has been developed for improving durability under high condition for long term. Since epoxy resin contains a lot of hydrogen and is comparatively resistant to heat, many casks employ epoxy base neutron shielding material. However, if the epoxy base neutron shielding material is used under high temperature condition for a long time, the material deteriorates and the moisture contained in it is released. The loss of moisture is in the range of several percents under more than 150 C. For this reason, our purpose was to develop a high durability epoxy base neutron shielding material which has the same self-fire-extinction property, high hydrogen content and so on as conventional. According to the long-time heating test, the weight loss of this new neutron shielding material after 5000 hours heating has been lower than 0.04% at 150 C and 0.35% at 170 C. A thermal test was also performed: a specimen of neutron shielding material covered with stainless steel was inserted in a furnace under condition of 800 C temperature for 30 minutes then was left to cool down in ambient conditions. The external view of the test piece shows that only a thin layer was carbonized
Self-transcendence and emotional well-being in women with advanced breast cancer.
Coward, D D
1991-07-01
Self-transcendence has been associated, in previous studies, with stressful life events and emotional well-being. This study examined the relationships among self-transcendence, emotional well-being, and illness-related distress in women with advanced breast cancer. The study employed a cross-sectional correlational design in a convenience sample (n = 107) of women with Stage IIIb and Stage IV breast cancer. Subjects completed a questionnaire that included Reed's Self-Transcendence Scale; Bradburn's Affect Balance Scale (ABS); a Cognitive Well-Being (CWB) Scale based on work by Campbell, Converse, and Rogers; McCorkle and Young's Symptom Distress Scale (SDS); and the Karnofsky Performance Scale (KPS). Data were analyzed using factor analytic structural equations modeling. Self-transcendence decreased illness distress (assessed by the SDS and the KPS) through the mediating effect of emotional well-being (assessed by the ABS and the CWB Scale). Self-transcendence directly affected emotional well-being (beta = 0.69), and emotional well-being had a strong negative effect on illness distress (beta = -0.84). A direct path from self-transcendence to illness distress (beta = -0.31) became nonsignificant (beta = -0.08) when controlling for emotional well-being. Further research using longitudinal data will seek to validate these relationships and to explain how nurses can promote self-transcendence in women with advanced breast cancer, as well as in others with life-threatening illnesses.
International Nuclear Information System (INIS)
Nakagawa, Takahiro; Yamagami, Makoto.
1996-01-01
A fixed shielding member made of a radiation shielding material is constituted in perpendicular to an opening formed on radiation shielding walls. The fixed shielding member has one side opened and has other side, the upper portion and the lower portion disposed in close contact with the radiation shielding walls. Movable shielding members made of a radiation shielding material are each disposed openably on both side of the fixed shielding member. The movable shielding member has a shaft as a fulcrum on one side thereof for connecting it to the radiation shielding walls. The other side has a handle attached for opening/closing the movable shielding member. Upon access of an operator, when each one of the movable shielding members is opened/closed on every time, leakage of linear or scattered radiation can be prevented. Even when both of the movable shielding members are opened simultaneously, the fixed shielding member and the movable shielding members form labyrinth to prevent leakage of linear radioactivity. (I.N.)
Development of a 1200 fine group nuclear data library for advanced nuclear systems
Institute of Scientific and Technical Information of China (English)
Jun Zou; Lei-Ming Shang; Fang Wang; Li-Juan Hao
2017-01-01
Accurate and reliable nuclear data libraries are essential for calculation and design of advanced nuclear systems.A 1200 fine group nuclear data library Hybrid Evaluated Nuclear Data Library/Fine Group (HENDL/FG) with neutrons of up to 150 MeV has been developed to improve the accuracy of neutronics calculations and analysis.Corrections of Doppler,resonance self-shielding,and thermal upscatter effects were done for HENDL/FG.Shielding and critical safety benchmarks were performed to test the accuracy and reliability of the library.The discrepancy between calculated and measured nuclear parameters fell into a reasonable range.
Directory of Open Access Journals (Sweden)
Rohola Hasanpour
2017-12-01
Full Text Available Severe shield jamming events have been reported during excavation of Uluabat tunnel through adverse geological conditions, which resulted in several stoppages at advancing a single shielded tunnel boring machine (TBM. To study the jamming mechanism, three-dimensional (3D simulation of the machine and surrounding ground was implemented using the finite difference code FLAC3D. Numerical analyses were performed for three sections along the tunnel with a higher risk for entrapment due to the combination of overburden and geological conditions. The computational results including longitudinal displacement contours and ground pressure profiles around the shield allow a better understanding of ground behavior within the excavation. Furthermore, they allow realistically assessing the impact of adverse geological conditions on shield jamming. The calculated thrust forces, which are required to move the machine forward, are in good agreement with field observations and measurements. It also proves that the numerical analysis can effectively be used for evaluating the effect of adverse geological environment on TBM entrapments and can be applied to prediction of loads on the shield and pre-estimating of the required thrust force during excavation through adverse ground conditions.
General Corrosion and Localized Corrosion of the Drip Shield
Energy Technology Data Exchange (ETDEWEB)
F. Hua
2004-09-16
The repository design includes a drip shield (BSC 2004 [DIRS 168489]) that provides protection for the waste package both as a barrier to seepage water contact and a physical barrier to potential rockfall. The purpose of the process-level models developed in this report is to model dry oxidation, general corrosion, and localized corrosion of the drip shield plate material, which is made of Ti Grade 7. This document is prepared according to ''Technical Work Plan For: Regulatory Integration Modeling and Analysis of the Waste Form and Waste Package'' (BSC 2004 [DIRS 171583]). The models developed in this report are used by the waste package degradation analyses for TSPA-LA and serve as a basis to determine the performance of the drip shield. The drip shield may suffer from other forms of failure such as the hydrogen induced cracking (HIC) or stress corrosion cracking (SCC), or both. Stress corrosion cracking of the drip shield material is discussed in ''Stress Corrosion Cracking of the Drip Shield, the Waste Package Outer Barrier, and the Stainless Steel Structural Material'' (BSC 2004 [DIRS 169985]). Hydrogen induced cracking of the drip shield material is discussed in ''Hydrogen Induced Cracking of Drip Shield'' (BSC 2004 [DIRS 169847]).
General Corrosion and Localized Corrosion of the Drip Shield
International Nuclear Information System (INIS)
F. Hua
2004-01-01
The repository design includes a drip shield (BSC 2004 [DIRS 168489]) that provides protection for the waste package both as a barrier to seepage water contact and a physical barrier to potential rockfall. The purpose of the process-level models developed in this report is to model dry oxidation, general corrosion, and localized corrosion of the drip shield plate material, which is made of Ti Grade 7. This document is prepared according to ''Technical Work Plan For: Regulatory Integration Modeling and Analysis of the Waste Form and Waste Package'' (BSC 2004 [DIRS 171583]). The models developed in this report are used by the waste package degradation analyses for TSPA-LA and serve as a basis to determine the performance of the drip shield. The drip shield may suffer from other forms of failure such as the hydrogen induced cracking (HIC) or stress corrosion cracking (SCC), or both. Stress corrosion cracking of the drip shield material is discussed in ''Stress Corrosion Cracking of the Drip Shield, the Waste Package Outer Barrier, and the Stainless Steel Structural Material'' (BSC 2004 [DIRS 169985]). Hydrogen induced cracking of the drip shield material is discussed in ''Hydrogen Induced Cracking of Drip Shield'' (BSC 2004 [DIRS 169847])
Radiation shielding for fusion reactors
International Nuclear Information System (INIS)
Santoro, R.T.
2000-01-01
Radiation shielding requirements for fusion reactors present different problems than those for fission reactors and accelerators. Fusion devices, particularly tokamak reactors, are complicated by geometry constraints that complicate disposition of fully effective shielding. This paper reviews some of these shielding issues and suggested solutions for optimizing the machine and biological shielding. Radiation transport calculations are essential for predicting and confirming the nuclear performance of the reactor and, as such, must be an essential part of the reactor design process. Development and optimization of reactor components from the first wall and primary shielding to the penetrations and containment shielding must be carried out in a sensible progression. Initial results from one-dimensional transport calculations are used for scoping studies and are followed by detailed two- and three-dimensional analyses to effectively characterize the overall radiation environment. These detail model calculations are essential for accounting for the radiation leakage through ports and other penetrations in the bulk shield. Careful analysis of component activation and radiation damage is cardinal for defining remote handling requirements, in-situ replacement of components, and personnel access at specific locations inside the reactor containment vessel. (author)
Self-shielding and burn-out effects in the irradiation of strongly-neutron-absorbing material
International Nuclear Information System (INIS)
Sekine, T.; Baba, H.
1978-01-01
Self-shielding and burn-out effects are discussed in the evaluation of radioisotopes formed by neutron irradiation of a strongly-neutron-absorbing material. A method of the evaluation of such effects is developed both for thermal and epithermal neutrons. Gadolinium oxide uniformly mixed with graphite powder was irradiated by reactor-neutrons together with pieces of a Co-Al alloy wire (the content of Co being 0.475%) as the neutron flux monitor. The configuration of the samples and flux monitors in each of two irradiations is illustrated. The yields of activities produced in the irradiated samples were determined by the γ-spectrometry with a Ge(Li) detector of a relative detection efficiency of 8%. Activities at the end of irradiation were estimated by corrections due to pile-up, self-absorption, detection efficiency, branching ratio, and decay of the activity. Results of the calculation are discussed in comparison with the observed yields of 153 Gd, 160 Tb, and 161 Tb for the case of neutron irradiation of disc-shaped targets of gadolinium oxide. (T.G.)
Work for radiation shielding concrete in large-scaled radiation facilities
International Nuclear Information System (INIS)
Konomi, Shinzo; Sato, Shoni; Otake, Takao.
1980-01-01
This paper reports the radiation shielding concrete work in the construction of radiation laboratory facilities of Electrotechnical Laboratory, a Japanese Government agency for the research and development of electronic technology. The radiation shielding walls of the facilities are made of ordinary concrete, heavy weight concrete and raw iron ore. This paper particularly relates the use of ordinary concrete which constitutes the majority of such concretes. The concrete mix was determined so as to increase its specific gravity for better shielding effect, to improve mass concrete effect and to advance good workability. The tendency of the concrete to decrease its specific gravity and the temperature variations were also made on how to place concrete to secure good shielding effect and uniform quality. (author)
Space Shielding Materials for Prometheus Application
Energy Technology Data Exchange (ETDEWEB)
R. Lewis
2006-01-20
At the time of Prometheus program restructuring, shield material and design screening efforts had progressed to the point where a down-selection from approximately eighty-eight materials to a set of five ''primary'' materials was in process. The primary materials were beryllium (Be), boron carbide (B{sub 4}C), tungsten (W), lithium hydride (LiH), and water (H{sub 2}O). The primary materials were judged to be sufficient to design a Prometheus shield--excluding structural and insulating materials, that had not been studied in detail. The foremost preconceptual shield concepts included: (1) a Be/B{sub 4}C/W/LiH shield; (2) a Be/B{sub 4}C/W shield; (3) and a Be/B{sub 4}C/H{sub 2}O shield. Since the shield design and materials studies were still preliminary, alternative materials (e.g., {sup nal}B or {sup 10}B metal) were still being screened, but at a low level of effort. Two competing low mass neutron shielding materials are included in the primary materials due to significant materials uncertainties in both. For LiH, irradiation-induced swelling was the key issue, whereas for H{sub 2}O, containment corrosion without active chemistry control was key, Although detailed design studies are required to accurately estimate the mass of shields based on either hydrogenous material, both are expected to be similar in mass, and lower mass than virtually any alternative. Unlike Be, W, and B{sub 4}C, which are not expected to have restrictive temperature limits, shield temperature limits and design accommodations are likely to be needed for either LiH or H{sub 2}O. The NRPCT focused efforts on understanding swelting of LiH, and observed, from approximately fifty prior irradiation tests, that either casting ar thorough out-gassing should reduce swelling. A potential contributor to LiH swelling appears to be LiOH contamination due to exposure to humid air, that can be eliminated by careful processing. To better understand LiH irradiation performance and
Energy Technology Data Exchange (ETDEWEB)
Price, Michael J.; Gifford, Kent A.; Horton, John L. Jr.; Eifel, Patricia J.; Gillin, Michael T.; Lawyer, Ann A.; Mourtada, Firas [Department of Radiation Physics, University of Texas M. D. Anderson Cancer Center, 1220 Holcombe Boulevard, Houston, Texas 77030 and Graduate School of Biomedical Sciences, University of Texas-Houston, 6767 Bertner Avenue, Houston, Texas 77030 (United States); Department of Radiation Physics, University of Texas M. D. Anderson Cancer Center, 1220 Holcombe Boulevard, Houston, Texas 77030 (United States); Division of Radiation Oncology, University of Texas M. D. Anderson Cancer Center, 1220 Holcombe Boulevard, Houston, Texas 77030 and Graduate School of Biomedical Sciences, University of Texas-Houston, 6767 Bertner Avenue, Houston, Texas 77030 (United States); Department of Radiation Physics, University of Texas M. D. Anderson Cancer Center, 1220 Holcombe Boulevard, Houston, Texas 77030 and Graduate School of Biomedical Sciences, University of Texas-Houston, 6767 Bertner Avenue, Houston, Texas 77030 (United States); Department of Radiation Physics, University of Texas M. D. Anderson Cancer Center, 1220 Holcombe Boulevard, Houston, Texas 77030 (United States); Department of Radiation Physics, University of Texas M. D. Anderson Cancer Center, 1220 Holcombe Boulevard, Houston, Texas 77030 and Graduate School of Biomedical Sciences, University of Texas-Houston, 6767 Bertner Avenue, Houston, Texas 77030 (United States)
2009-09-15
Purpose: Current, clinically applicable intracavitary brachytherapy applicators that utilize shielded ovoids contain a pair of tungsten-alloy shields which serve to reduce dose delivered to the rectum and bladder during source afterloading. After applicator insertion, these fixed shields are not necessarily positioned to provide optimal shielding of these critical structures due to variations in patient anatomies. The authors present a dosimetric evaluation of a novel prototype intracavitary brachytherapy ovoid [anatomically adaptive applicator (A{sup 3})], featuring a single shield whose position can be adjusted with two degrees of freedom: Rotation about and translation along the long axis of the ovoid. Methods: The dosimetry of the device for a HDR {sup 192}Ir was characterized using radiochromic film measurements for various shield orientations. A MCNPX Monte Carlo model was developed of the prototype ovoid and integrated with a previously validated model of a v2 mHDR {sup 192}Ir source (Nucletron Co.). The model was validated for three distinct shield orientations using film measurements. Results: For the most complex case, 91% of the absolute simulated and measured dose points agreed within 2% or 2 mm and 96% agreed within 10% or 2 mm. Conclusions: Validation of the Monte Carlo model facilitates future investigations into any dosimetric advantages the use of the A{sup 3} may have over the current state of art with respect to optimization and customization of dose delivery as a function of patient anatomical geometries.
International Nuclear Information System (INIS)
Price, Michael J.; Gifford, Kent A.; Horton, John L. Jr.; Eifel, Patricia J.; Gillin, Michael T.; Lawyer, Ann A.; Mourtada, Firas
2009-01-01
Purpose: Current, clinically applicable intracavitary brachytherapy applicators that utilize shielded ovoids contain a pair of tungsten-alloy shields which serve to reduce dose delivered to the rectum and bladder during source afterloading. After applicator insertion, these fixed shields are not necessarily positioned to provide optimal shielding of these critical structures due to variations in patient anatomies. The authors present a dosimetric evaluation of a novel prototype intracavitary brachytherapy ovoid [anatomically adaptive applicator (A 3 )], featuring a single shield whose position can be adjusted with two degrees of freedom: Rotation about and translation along the long axis of the ovoid. Methods: The dosimetry of the device for a HDR 192 Ir was characterized using radiochromic film measurements for various shield orientations. A MCNPX Monte Carlo model was developed of the prototype ovoid and integrated with a previously validated model of a v2 mHDR 192 Ir source (Nucletron Co.). The model was validated for three distinct shield orientations using film measurements. Results: For the most complex case, 91% of the absolute simulated and measured dose points agreed within 2% or 2 mm and 96% agreed within 10% or 2 mm. Conclusions: Validation of the Monte Carlo model facilitates future investigations into any dosimetric advantages the use of the A 3 may have over the current state of art with respect to optimization and customization of dose delivery as a function of patient anatomical geometries.
Exploring Self-Efficacy among Entry-Level and Advanced BSW Students
Simmons, Christopher; Fisher, Amy Killen; Barnard, Marie; Allen, Susan C.
2017-01-01
This study compared a sample of entry-level and advanced BSW students, who completed pretest and posttest self-efficacy measures, to assess their level of confidence in performing social work tasks after 15 weeks of instruction. By the end of the semester, only advanced students made significant gains in self-efficacy beliefs, and they showed a…
Hydrogen Induced Cracking of Drip Shield
Energy Technology Data Exchange (ETDEWEB)
G. De
2003-02-24
One potential failure mechanism for titanium and its alloys under repository conditions is via the absorption of atomic hydrogen in the metal crystal lattice. The resulting decreased ductility and fracture toughness may lead to brittle mechanical fracture called hydrogen-induced cracking (HIC) or hydrogen embrittlement. For the current design of the engineered barrier without backfill, HIC may be a problem since the titanium drip shield can be galvanically coupled to rock bolts (or wire mesh), which may fall onto the drip shield, thereby creating conditions for hydrogen production by electrochemical reaction. The purpose of this scientific analysis and modeling activity is to evaluate whether the drip shield will fail by HIC or not under repository conditions within 10,000 years of emplacement. This Analysis and Model Report (AMR) addresses features, events, and processes related to hydrogen induced cracking of the drip shield. REV 00 of this AMR served as a feed to ''Waste Package Degradation Process Model Report'' and was developed in accordance with the activity section ''Hydrogen Induced Cracking of Drip Shield'' of the development plan entitled ''Analysis and Model Reports to Support Waste Package PMR'' (CRWMS M&O 1999a). This AMR, prepared according to ''Technical Work Plan for: Waste Package Materials Data Analyses and Modeling'' (BSC 2002), is to feed the License Application.
Shielding design to obtain compact marine reactor
International Nuclear Information System (INIS)
Yamaji, Akio; Sako, Kiyoshi
1994-01-01
The marine reactors equipped in previously constructed nuclear ships are in need of the secondary shield which is installed outside the containment vessel. Most of the weight and volume of the reactor plants are occupied by this secondary shield. An advanced marine reactor called MRX (Marine Reactor X) has been designed to obtain a more compact and lightweight marine reactor with enhanced safety. The MRX is a new type of marine reactor which is an integral PWR (The steam generator is installed in the pressure vessel.) with adopting a water-filled containment vessel and a new shielding design method of no installation of the secondary shield. As a result, MRX is considerably lighter in weight and more compact in size as compared with the reactors equipped in previously constructed nuclear ships. For instance, the plant weight and volume of the containment vessel of MRX are about 50% and 70% of those of the Nuclear Ship MUTSU, in spite of the power of MRX is 2.8 times as large as the MUTSU's reactor. The shielding design calculation was made using the ANISN, DOT3.5, QAD-CGGP2 and ORIGEN codes. The computational accuracy was confirmed by experimental analyses. (author)
International Nuclear Information System (INIS)
Makishima, Kenji.
1986-01-01
Purpose: In shielding plugs of an LMFBR type reactor, to restrain natural convection of heat in an annular space between a thermal shield layer and a shield shell, to prevent the lowering of heat-insulation performance, and to alleviate a thermal stress in a reactor container and the shield shell. Constitution: A ring-like leaf spring split in the direction of height is disposed in an annular space between a thermal shield layer and a shield shell. In consequence, the space is partitioned in the direction of height and, therefore, if axial temperature conditions and space width are the same and the space is low, the natural convection is hard to occur. Thus the rise of upper surface temperature of the shielding plugs can prevent the lowering of the heat insulation performance which will result in the increment of shielding plug cooling capacity, thereby improving reliability. In the meantime, since there is mounted an earthquake-resisting support, the thermal shield layer will move for a slight gap in case of an earthquake, being supported by the earthquake-resisting support, and the movement of the thermal shield layer is restricted, thereby maintaining integrity without increasing the stroke of the ring-like spring. (Kawakami, Y.)
Application of Advanced Radiation Shielding Materials to Inflatable Structures, Phase I
National Aeronautics and Space Administration — This innovation is a weight-optimized, inflatable structure that incorporates radiation shielding materials into its construction, for use as a habitation module or...
Hot Cell Window Shielding Analysis Using MCNP
International Nuclear Information System (INIS)
Pope, Chad L.; Scates, Wade W.; Taylor, J. Todd
2009-01-01
The Idaho National Laboratory Materials and Fuels Complex nuclear facilities are undergoing a documented safety analysis upgrade. In conjunction with the upgrade effort, shielding analysis of the Fuel Conditioning Facility (FCF) hot cell windows has been conducted. This paper describes the shielding analysis methodology. Each 4-ft thick window uses nine glass slabs, an oil film between the slabs, numerous steel plates, and packed lead wool. Operations in the hot cell center on used nuclear fuel (UNF) processing. Prior to the shielding analysis, shield testing with a gamma ray source was conducted, and the windows were found to be very effective gamma shields. Despite these results, because the glass contained significant amounts of lead and little neutron absorbing material, some doubt lingered regarding the effectiveness of the windows in neutron shielding situations, such as during an accidental criticality. MCNP was selected as an analysis tool because it could model complicated geometry, and it could track gamma and neutron radiation. A bounding criticality source was developed based on the composition of the UNF. Additionally, a bounding gamma source was developed based on the fission product content of the UNF. Modeling the windows required field inspections and detailed examination of drawings and material specifications. Consistent with the shield testing results, MCNP results demonstrated that the shielding was very effective with respect to gamma radiation, and in addition, the analysis demonstrated that the shielding was also very effective during an accidental criticality.
Experimental analysis of an MIM capacitor with a concave shield
International Nuclear Information System (INIS)
Liu Lintao; Yu Mingyan; Wang Jinxiang
2009-01-01
A novel shielding scheme is developed by inserting a concave shield between a metal-insulator-metal (MIM) capacitor and the silicon substrate. Chip measurements reveal that the concave shield improves the quality factor by 11% at 11.8 GHz and 14% at 18.8 GHz compared with an unshielded MIM capacitor. It also alleviates the effect on shunt capacitance between the bottom plate of the MIM capacitor and the shield layer. Moreover, because the concave shields simplify substrate modeling, a simple circuit model of the MIM capacitor with concave shield is presented for radio frequency applications.
SP-100 GES/NAT radiation shielding systems design and development testing
International Nuclear Information System (INIS)
Disney, R.K.; Kulikowski, H.D.; McGinnis, C.A.; Reese, J.C.; Thomas, K.; Wiltshire, F.
1991-01-01
Advanced Energy Systems (AES) of Westinghouse Electric Corporation is under subcontract to the General Electric Company to supply nuclear radiation shielding components for the SP-100 Ground Engineering System (GES) Nuclear Assembly Test to be conducted at Westinghouse Hanford Company at Richland, Washington. The radiation shielding components are integral to the Nuclear Assembly Test (NAT) assembly and include prototypic and non-prototypic radiation shielding components which provide prototypic test conditions for the SP-100 reactor subsystem and reactor control subsystem components during the GES/NAT operations. W-AES is designing three radiation shield components for the NAT assembly; a prototypic Generic Flight System (GFS) shield, the Lower Internal Facility Shield (LIFS), and the Upper Internal Facility Shield (UIFS). This paper describes the design approach and development testing to support the design, fabrication, and assembly of these three shield components for use within the vacuum vessel of the GES/NAT. The GES/NAT shields must be designed to operate in a high vacuum which simulates space operations. The GFS shield and LIFS must provide prototypic radiation/thermal environments and mechanical interfaces for reactor system components. The NAT shields, in combination with the test facility shielding, must provide adequate radiation attenuation for overall test operations. Special design considerations account for the ground test facility effects on the prototypic GFS shield. Validation of the GFS shield design and performance will be based on detailed Monte Carlo analyses and developmental testing of design features. Full scale prototype testing of the shield subsystems is not planned
The use of portable shields in industrial radiography
International Nuclear Information System (INIS)
Oliveira e Silva, J.A. de.
1988-01-01
This paper shows techniques actually used to reduce radiations exposure taxes during examinations execution by gamma radiography in regions of high population density. A portable equipment of radiation shield for using in exams by gamma radiography in pipelines, that is an adjustable device in an object body that will be examined, joining a measured collimator and a shield geometrically arranged so that the radiation restrict to impress the radiographic film used in examination without reaching people, objects or self-movings injurious that are nearness. (C.M.) [pt
Energy Technology Data Exchange (ETDEWEB)
Sah, Sanjay [Virginia Commonwealth Univ., Richmond, VA (United States)
2016-05-31
Particle accelerators produce beams of high-energy particles, which are used for both fundamental and applied scientific research and are critical to the development of accelerator driven sub-critical reactor systems. An effective magnetic shield is very important to achieve higher quality factor (Qo) of the cryomodule of a particle accelerator. The allowed value of field inside the cavity due to all external fields (particularly the Earth’s magnetic field) is ~15 mG or less. The goal of this PhD dissertation is to comprehensively study the magnetic properties of commonly used magnetic shielding materials at both cryogenic and room temperatures. This knowledge can be used for the enhanced design of magnetic shields of cryomodes (CM) in particle accelerators. To this end, we first studied the temperature dependent magnetization behavior (M-H curves) of Amumetal and A4K under different annealing and deformation conditions. This characterized the effect of stress or deformation induced during the manufacturing processes and subsequent restoration of high permeability with appropriate heat treatment. Next, an energy based stochastic model for temperature dependent anhysteretic magnetization behavior of ferromagnetic materials was proposed and benchmarked against experimental data. We show that this model is able to simulate and explain the magnetic behavior of as rolled, deformed and annealed amumetal and A4K over a large range of temperatures. The experimental results for permeability are then used in a finite element model (FEM) in COMSOL to evaluate the shielding effectiveness of multiple shield designs at room temperature as well as cryogenic temperature. This work could serve as a guideline for future design, development and fabrication of magnetic shields of CMs.
Nuclear reactions and self-shielding effects of gamma-ray database for nuclear materials
Energy Technology Data Exchange (ETDEWEB)
Fujita, Mitsutane; Noda, Tetsuji [National Research Institute for Metals, Tsukuba, Ibaraki (Japan)
2001-03-01
A database for transmutation and radioactivity of nuclear materials is required for selection and design of materials used in various nuclear reactors. The database based on the FENDL/A-2.0 on the Internet and the additional data collected from several references has been developed in NRIM site of 'Data-Free-Way' on the Internet. Recently, the function predicted self-shielding effect of materials for {gamma}-ray was added to this database. The user interface for this database has been constructed for retrieval of necessary data and for graphical presentation of the relation between the energy spectrum of neutron and neutron capture cross section. It is demonstrated that the possibility of chemical compositional change and radioactivity in a material caused by nuclear reactions can be easily retrieved using a browser such as Netscape or Explorer. (author)
Nuclear reactions and self-shielding effects of gamma-ray database for nuclear materials
International Nuclear Information System (INIS)
Fujita, Mitsutane; Noda, Tetsuji
2001-01-01
A database for transmutation and radioactivity of nuclear materials is required for selection and design of materials used in various nuclear reactors. The database based on the FENDL/A-2.0 on the Internet and the additional data collected from several references has been developed in NRIM site of 'Data-Free-Way' on the Internet. Recently, the function predicted self-shielding effect of materials for γ-ray was added to this database. The user interface for this database has been constructed for retrieval of necessary data and for graphical presentation of the relation between the energy spectrum of neutron and neutron capture cross section. It is demonstrated that the possibility of chemical compositional change and radioactivity in a material caused by nuclear reactions can be easily retrieved using a browser such as Netscape or Explorer. (author)
Reliability of Monte Carlo simulations in modeling neutron yields from a shielded fission source
Energy Technology Data Exchange (ETDEWEB)
McArthur, Matthew S., E-mail: matthew.s.mcarthur@gmail.com; Rees, Lawrence B., E-mail: Lawrence_Rees@byu.edu; Czirr, J. Bart, E-mail: czirr@juno.com
2016-08-11
Using the combination of a neutron-sensitive {sup 6}Li glass scintillator detector with a neutron-insensitive {sup 7}Li glass scintillator detector, we are able to make an accurate measurement of the capture rate of fission neutrons on {sup 6}Li. We used this detector with a {sup 252}Cf neutron source to measure the effects of both non-borated polyethylene and 5% borated polyethylene shielding on detection rates over a range of shielding thicknesses. Both of these measurements were compared with MCNP calculations to determine how well the calculations reproduced the measurements. When the source is highly shielded, the number of interactions experienced by each neutron prior to arriving at the detector is large, so it is important to compare Monte Carlo modeling with actual experimental measurements. MCNP reproduces the data fairly well, but it does generally underestimate detector efficiency both with and without polyethylene shielding. For non-borated polyethylene it underestimates the measured value by an average of 8%. This increases to an average of 11% for borated polyethylene.
Particle Tracing Modeling with SHIELDS
Woodroffe, J. R.; Brito, T. V.; Jordanova, V. K.
2017-12-01
The near-Earth inner magnetosphere, where most of the nation's civilian and military space assets operate, is an extremely hazardous region of the space environment which poses major risks to our space infrastructure. Failure of satellite subsystems or even total failure of a spacecraft can arise for a variety of reasons, some of which are related to the space environment: space weather events like single-event-upsets and deep dielectric charging caused by high energy particles, or surface charging caused by low to medium energy particles; other space hazards are collisions with natural or man-made space debris, or intentional hostile acts. A recently funded project through the Los Alamos National Laboratory (LANL) Directed Research and Development (LDRD) program aims at developing a new capability to understand, model, and predict Space Hazards Induced near Earth by Large Dynamic Storms, the SHIELDS framework. The project goals are to understand the dynamics of the surface charging environment (SCE), the hot (keV) electrons on both macro- and microscale. These challenging problems are addressed using a team of world-class experts and state-of-the-art physics-based models and computational facilities. We present first results of a coupled BATS-R-US/RAM-SCB/Particle Tracing Model to evaluate particle fluxes in the inner magnetosphere. We demonstrate that this setup is capable of capturing the earthward particle acceleration process resulting from dipolarization events in the tail region of the magnetosphere.
Simulation of divertor targets shielding during transients in ITER
Energy Technology Data Exchange (ETDEWEB)
Pestchanyi, Sergey, E-mail: serguei.pestchanyi@kit.edu [KIT, Hermann-von-Helmholtz-Platz 1, Eggenstein-Leopoldshafen (Germany); Pitts, Richard; Lehnen, Michael [ITER Organization,Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France)
2016-11-01
Highlights: • We simulated plasma shielding effect during disruption in ITER using the TOKES code. • It has been found that vaporization is unavoidable under action of ITER transients, but plasma shielding drastically reduces the divertor target damage: the melt pool and the vaporization region widths reduced 10–15 times. • A simplified 1D model describing the melt pool depth and the shielded heat flux to the divertor targets have been developed. • The results of the TOKES simulations have been compared with the analytic model when the model is valid. - Abstract: Direct extrapolation of the disruptive heat flux on ITER conditions predicts severe melting and vaporization of the divertor targets causing their intolerable damage. However, tungsten vaporized from the target at initial stage of the disruption can create plasma shield in front of the target, which effectively protects the target surface from the rest of the heat flux. Estimation of this shielding efficiency has been performed using the TOKES code. The shielding effect under ITER conditions is found to be very strong: the maximal depth of the melt layer reduced 4 times, the melt layer width—more than 10 times and vaporization region shrinks 10–15 times due to shielding for unmitigated disruption of 350 MJ discharge. The simulation results show complex, 2D plasma dynamics of the shield under ITER conditions. However, a simplified analytic model, valid for rough estimation of the maximum value for the shielded flux to the target and for the melt depth at the target surface has been developed.
Energy Technology Data Exchange (ETDEWEB)
Burnside, W [Mountain View, CA (United States)
2015-06-15
Purpose: Xoft provides a set of 316L Stainless Steel Rigid Shields to be used with their 50 kV X-ray source for Breast IORT treatments. Modeling the different shield sizes in MCNP provides information to help make clinical decisions for selecting the appropriate shield size. Methods: The Xoft Axxent 50 kV Electronic Brachytherapy System has several applications in radiation therapy, one of which is treating cancer of the breast intraoperatively by placing the miniaturized X-ray tube inside an applicator balloon that is expanded to fill the lumpectomy bed immediately following tumor removal. The ribs, lung, and muscular chest wall are all regions at risk to receive undesired dose during the treatment. A Xoft 316L Stainless Steel Rigid Shield can be placed between the intracostal muscles of the chest wall and the remaining breast tissue near the balloon to attenuate the beam and protect these organs. These shields are provided in 5 different sizes, and the effects on dose to the surrounding tissues vary with shield size. MCNP was used to model this environment and tally dose rate to certain regions of interest. Results: The average rib dose rate calculated using 0cm (i.e., no shield), 3cm, and 5cm diameter shields were 26.89, 15.43, and 8.91 Gy/hr respectively. The maximum dose rates within the rib reached 94.74 Gy/hr, 53.56 Gy/hr, and 31.44 Gy/hr for the 0cm, 3cm, and 5cm cases respectively. The shadowing effect caused by the steel shields was seen in the 3-D meshes and line profiles. Conclusion: This model predicts a higher dose rate to the underlying rib region with the 3cm shield compared to the 5cm shield; it may be useful to select the largest possible diameter when choosing a shield size for a particular IORT patient. The ability to attenuate the beam to reduce rib dose was also confirmed. Research sponsored by Xoft Inc, a subsidiary of iCAD.
2016-03-31
AFRL-AFOSR-VA-TR-2016-0309 Predictive simulation of material failure using peridynamics- advanced constitutive modeling, verification , and validation... Self -explanatory. 8. PERFORMING ORGANIZATION REPORT NUMBER. Enter all unique alphanumeric report numbers assigned by the performing organization, e.g...for public release. Predictive simulation of material failure using peridynamics-advanced constitutive modeling, verification , and validation John T
Unresolved resonance range cross section, probability tables and self shielding factor
International Nuclear Information System (INIS)
Sublet, J.Ch.; Blomquist, R.N.; Goluoglu, S.; Mac Farlane, R.E.
2009-07-01
The performance and methodology of 4 processing codes have been compared in the unresolved resonance range of a selected set of isotopes. Those isotopes have been chosen to encompass most cases encountered in the unresolved energy range contained in major libraries like Endf/B-7 or Jeff-3.1.1. The code results comparison is accompanied by data format and formalism examinations and processing code fine-interpretation study. After some improvements, the results showed generally good agreement, although not perfect with infinite dilute cross-sections. However, much larger differences occur when shelf-shielded effective cross-sections are compared. The infinitely dilute cross-section are often plot checked but it is the probability table derived and shelf-shielded cross sections that are used and interpreted in criticality and transport calculations. This suggests that the current evaluation data format and formalism, in the unresolved resonance range should be tightened up, ambiguities removed. In addition production of the shelf shielded cross-sections should be converged to a much greater accuracy. (author)
Preliminary evaluation of FY98 KALIMER shielding design
Energy Technology Data Exchange (ETDEWEB)
Yoo, Jae Woon; Kang, Chang Mu; Kim, Young Jin [Korea Atomic Energy Research Institute, Taejon (Korea)
1999-01-01
This report describes a preliminary evaluation of the shielding design of FY98 KALIMER. The KALIMER shielding design includes the Inner Fixed Shield of a stainless cylinder located inside the support barrel; the Radial PSDRS Shields which are three B{sub 4}C cylinders located outside the support barrel at core level; the Lower IHX shield of a cylindrical B{sub 4}C plate located above the flow guide; and Inner and Outer IHX shields of B{sub 4}C cylinders located inside and outside of the support barrel, respectively. The DORT3.1 two-dimensional transport code was used to evaluate the KALIMER shielding design. The reactor system was represented by four axial zones, each of which was modeled in the R-Z geometry. The KAFAX-F22 library was used in the analyses, which was generated from the JEF-2.2 of OECD/NEA files for LMR applications by KAERI. The performance of the KALIMER shielding design is compared against the shielding design criteria. The results indicate that the support barrel, upper grid plate, and other reactor structures meet the maximum neutron fluence and DPA limits established in the shielding design criteria. Activities of the air effluent in the PSDRS were also evaluated and are shown to satisfy the maximum permissible concentration (MPC) limits in 10 CFR Part 20. In the future, the validation of the DORT model by a detailed three dimensional calculation such as MCNP and the justification of the current shielding design limits are needed. (author). 13 refs., 23 figs., 31 tabs.
International Nuclear Information System (INIS)
Palma, Daniel A.; Goncalves, Alessandro C.; Martinez, Aquilino S.; Silva, Fernando C.
2008-01-01
The activation technique allows much more precise measurements of neutron intensity, relative or absolute. The technique requires the knowledge of the Doppler broadening function ψ(x,ξ) to determine the resonance self-shielding factors in the epithermal range G epi (τ,ξ). Two new analytical approximations for the Doppler broadening function ψ(x,ξ) are proposed. The approximations proposed are compared with other methods found in literature for the calculation of the ψ(x,ξ) function, that is, the 4-pole Pade method and the Frobenius method, when applied to the calculation of G epi (τ,ξ). The results obtained provided satisfactory accuracy. (authors)
Energy Technology Data Exchange (ETDEWEB)
Palma, Daniel A. [CEFET QUIMICA de Nilopolis/RJ, Rio de Janeiro (Brazil); Goncalves, Alessandro C.; Martinez, Aquilino S.; Silva, Fernando C. [COPPE/UFRJ - Programa de Engenharia Nuclear, Rio de Janeiro (Brazil)
2008-07-01
The activation technique allows much more precise measurements of neutron intensity, relative or absolute. The technique requires the knowledge of the Doppler broadening function psi(x,xi) to determine the resonance self-shielding factors in the epithermal range G{sub epi} (tau,xi). Two new analytical approximations for the Doppler broadening function psi(x,xi) are proposed. The approximations proposed are compared with other methods found in literature for the calculation of the psi(x,xi) function, that is, the 4-pole Pade method and the Frobenius method, when applied to the calculation of G{sub epi} (tau,xi). The results obtained provided satisfactory accuracy. (authors)
Passive magnetic shielding in MRI-Linac systems
Whelan, Brendan; Kolling, Stefan; Oborn, Brad M.; Keall, Paul
2018-04-01
Passive magnetic shielding refers to the use of ferromagnetic materials to redirect magnetic field lines away from vulnerable regions. An application of particular interest to the medical physics community is shielding in MRI systems, especially integrated MRI-linear accelerator (MRI-Linac) systems. In these systems, the goal is not only to minimize the magnetic field in some volume, but also to minimize the impact of the shield on the magnetic fields within the imaging volume of the MRI scanner. In this work, finite element modelling was used to assess the shielding of a side coupled 6 MV linac and resultant heterogeneity induced within the 30 cm diameter of spherical volume (DSV) of a novel 1 Tesla split bore MRI magnet. A number of different shield parameters were investigated; distance between shield and magnet, shield shape, shield thickness, shield length, openings in the shield, number of concentric layers, spacing between each layer, and shield material. Both the in-line and perpendicular MRI-Linac configurations were studied. By modifying the shield shape around the linac from the starting design of an open ended cylinder, the shielding effect was boosted by approximately 70% whilst the impact on the magnet was simultaneously reduced by approximately 10%. Openings in the shield for the RF port and beam exit were substantial sources of field leakage; however it was demonstrated that shielding could be added around these openings to compensate for this leakage. Layering multiple concentric shield shells was highly effective in the perpendicular configuration, but less so for the in-line configuration. Cautious use of high permeability materials such as Mu-metal can greatly increase the shielding performance in some scenarios. In the perpendicular configuration, magnetic shielding was more effective and the impact on the magnet lower compared with the in-line configuration.
AP1000 shield building: a constructability challenge
International Nuclear Information System (INIS)
Di Giuseppe, Giovanni; Bonanno, Domenico
2010-01-01
The AP1000 Shield Building, an enhanced structure which surrounds the containment vessel, consists of standard Reinforced Concrete (RC) and composite Steel and Concrete (SC) construction. In the SC module the surface steel plates, (with attached shear studs and angles) filled with concrete, act as the steel reinforcement in concrete. This is a relatively new design technology that required the appropriate use of structural codes, supplemented with information from applicable tests on similar composite steel and concrete construction. Being a newer design concept, existing codes do not provide explicit guidance on SC construction so a review of literature and test data on composite structures similar to AP1000 shield building was done in order to confirm the technical basis for the design. The SC walls, air inlet structure and roof of the Shield Building will be constructed using modular construction practices and then transported to site and lifted into place. These modules, working also as permanent form-work, will be filled with high strength Self- Consolidating Concrete. (SCC) This paper provides a focused and integrated presentation of the enhanced shield building design methodology, testing, constructability and inspection. (authors)
First Wall, Blanket, Shield Engineering Technology Program
International Nuclear Information System (INIS)
Nygren, R.E.
1982-01-01
The First Wall/Blanket/Shield Engineering Technology Program sponsored by the Office of Fusion Energy of DOE has the overall objective of providing engineering data that will define performance parameters for nuclear systems in advanced fusion reactors. The program comprises testing and the development of computational tools in four areas: (1) thermomechanical and thermal-hydraulic performance of first-wall component facsimiles with emphasis on surface heat loads; (2) thermomechanical and thermal-hydraulic performance of blanket and shield component facsimiles with emphasis on bulk heating; (3) electromagnetic effects in first wall, blanket, and shield component facsimiles with emphasis on transient field penetration and eddy-current effects; (4) assembly, maintenance and repair with emphasis on remote-handling techniques. This paper will focus on elements 2 and 4 above and, in keeping with the conference participation from both fusion and fission programs, will emphasize potential interfaces between fusion technology and experience in the fission industry
Radiation shielding for neutron guides
International Nuclear Information System (INIS)
Ersez, T.; Braoudakis, G.; Osborn, J.C.
2005-01-01
Full text: Models of the neutron guide shielding for the out of bunker guides on the thermal and cold neutron beam lines of the OPAL Reactor (ANSTO) were constructed using the Monte Carlo code MCNP 4B. The neutrons that were not reflected inside the guides but were absorbed by the supermirror (SM) layers were noted to be a significant source of gammas. Gammas also arise from neutrons absorbed by the B, Si, Na and K contained in the glass. The proposed shielding design has produced compact shielding assemblies. These arrangements are consistent with safety requirements, floor load limits, and cost constraints. To verify the design a prototype was assembled consisting of 120mm thick Pb(96%)Sb(4%) walls resting on a concrete block. There was good agreement between experimental measurements and calculated dose rates for bulk shield regions. (authors)
Radiation shielding for neutron guides
International Nuclear Information System (INIS)
Ersez, T.; Braoudakis, G.; Osborn, J.C.
2006-01-01
Models of the neutron guide shielding for the out of bunker guides on the thermal and cold neutron beam lines of the OPAL Reactor (ANSTO) were constructed using the Monte Carlo code MCNP 4B. The neutrons that were not reflected inside the guides but were absorbed by the supermirror (SM) layers were noted to be a significant source of gammas. Gammas also arise from neutrons absorbed by the B, Si, Na and K contained in the glass. The proposed shielding design has produced compact shielding assemblies. These arrangements are consistent with safety requirements, floor load limits, and cost constraints. To verify the design a prototype was assembled consisting of 120 mm thick Pb(96%)Sb(4%) walls resting on a concrete block. There was good agreement between experimental measurements and calculated dose rates for bulk shield regions
Modelling the self-organization and collapse of complex networks
Indian Academy of Sciences (India)
Modelling the self-organization and collapse of complex networks. Sanjay Jain Department of Physics and Astrophysics, University of Delhi Jawaharlal Nehru Centre for Advanced Scientific Research, Bangalore Santa Fe Institute, Santa Fe, New Mexico.
Energy Technology Data Exchange (ETDEWEB)
K. Mon
2001-08-29
This analyses and models report (AMR) was conducted in response to written work direction (CRWMS M and O 1999a). ICN 01 of this AMR was developed following guidelines provided in TWP-MGR-MD-000004 REV 01, ''Technical Work Plan for: Integrated Management of Technical Product Input Department'' (BSC 2001, Addendum B). The purpose and scope of this AMR is to review and analyze upstream process-level models (CRWMS M and O 2000a and CRWMS M and O 2000b) and information relevant to pitting and crevice corrosion degradation of waste package outer barrier (Alloy 22) and drip shield (Titanium Grade 7) materials, and to develop abstractions of the important processes in a form that is suitable for input to the WAPDEG analysis for long-term degradation of waste package outer barrier and drip shield in the repository. The abstraction is developed in a manner that ensures consistency with the process-level models and information and captures the essential behavior of the processes represented. Also considered in the model abstraction are the probably range of exposure conditions in emplacement drifts and local exposure conditions on drip shield and waste package surfaces. The approach, method, and assumptions that are employed in the model abstraction are documented and justified.
International Nuclear Information System (INIS)
Mon, K.
2001-01-01
This analyses and models report (AMR) was conducted in response to written work direction (CRWMS M and O 1999a). ICN 01 of this AMR was developed following guidelines provided in TWP-MGR-MD-000004 REV 01, ''Technical Work Plan for: Integrated Management of Technical Product Input Department'' (BSC 2001, Addendum B). The purpose and scope of this AMR is to review and analyze upstream process-level models (CRWMS M and O 2000a and CRWMS M and O 2000b) and information relevant to pitting and crevice corrosion degradation of waste package outer barrier (Alloy 22) and drip shield (Titanium Grade 7) materials, and to develop abstractions of the important processes in a form that is suitable for input to the WAPDEG analysis for long-term degradation of waste package outer barrier and drip shield in the repository. The abstraction is developed in a manner that ensures consistency with the process-level models and information and captures the essential behavior of the processes represented. Also considered in the model abstraction are the probably range of exposure conditions in emplacement drifts and local exposure conditions on drip shield and waste package surfaces. The approach, method, and assumptions that are employed in the model abstraction are documented and justified
Magnetic shielding for coreless linear permanent magnet motors
Pluk, K.J.W.; Jansen, J.W.; Lomonova, E.
2013-01-01
This paper concerns the local reduction of the magnetic flux density by means of magnetic shielding. Using a spatial frequency description, a 2-D semi-analytical periodic model is obtained for a coreless single-sided linear permanent magnet motor. The magnetic shield is included in the modeling
Bays, Harold E; Bazata, Debbra D; Clark, Nathaniel G; Gavin, James R; Green, Andrew J; Lewis, Sandra J; Reed, Michael L; Stewart, Walter; Chapman, Richard H; Fox, Kathleen M; Grandy, Susan
2007-10-03
Studies derived from continuous national surveys have shown that the prevalence of diagnosed diabetes mellitus in the US is increasing. This study estimated the prevalence in 2004 of self-reported diagnosis of diabetes and other conditions in a community-based population, using data from the Study to Help Improve Early evaluation and management of risk factors Leading to Diabetes (SHIELD). The initial screening questionnaire was mailed in 2004 to a stratified random sample of 200,000 households in the US, to identify individuals, age > or = 18 years of age, with diabetes or risk factors associated with diabetes. Follow-up disease impact questionnaires were then mailed to a representative, stratified random sample of individuals (n = 22,001) in each subgroup of interest (those with diabetes or different numbers of risk factors for diabetes). Estimated national prevalence of diabetes and other conditions was calculated, and compared to prevalence estimates from the National Health and Nutrition Examination Survey (NHANES) 1999-2002. Response rates were 63.7% for the screening, and 71.8% for the follow-up baseline survey. The SHIELD screening survey found overall prevalence of self-reported diagnosis of diabetes (either type 1 or type 2) was 8.2%, with increased prevalence with increasing age and decreasing income. In logistic regression modeling, individuals were more likely to be diagnosed with type 2 diabetes if they had abdominal obesity (odds ratio [OR] = 3.50; p or =28 kg/m2 (OR = 4.04; p self-report only) to those from NHANES 1999-2002 (self-report, clinical and laboratory evaluations), the prevalence of diabetes was similar. SHIELD allows the identification of respondents with and without a current diagnosis of the illness of interest, and potential longitudinal evaluation of risk factors for future diagnosis of that illness.
Preliminary shielding analysis of VHTR reactors
International Nuclear Information System (INIS)
Flaspoehler, Timothy M.; Petrovic, Bojan
2011-01-01
Over the last 20 years a number of methods have been established for automated variance reduction in Monte Carlo shielding simulations. Hybrid methods rely on deterministic adjoint and/or forward calculations to generate these parameters. In the present study, we use the FWCADIS method implemented in MAVRIC sequence of the SCALE6 package to perform preliminary shielding analyses of a VHTR reactor. MAVRIC has been successfully used by a number of researchers for a range of shielding applications, including modeling of LWRs, spent fuel storage, radiation field throughout a nuclear power plant, study of irradiation facilities, and others. However, experience in using MAVRIC for shielding studies of VHTRs is more limited. Thus, the objective of this work is to contribute toward validating MAVRIC for such applications, and identify areas for potential improvement. A simplified model of a prismatic VHTR has been devised, based on general features of the 600 MWt reactor considered as one of the NGNP options. Fuel elements have been homogenized, and the core region is represented as an annulus. However, the overall mix of materials and the relatively large dimensions of the spatial domain challenging the shielding simulations have been preserved. Simulations are performed to evaluate fast neutron fluence, dpa, and other parameters of interest at relevant positions. The paper will investigate and discuss both the effectiveness of the automated variance reduction, as well as applicability of physics model from the standpoint of specific VHTR features. (author)
Capsule shields the function of short bacterial adhesins
DEFF Research Database (Denmark)
Schembri, Mark; Dalsgaard, D.; Klemm, Per
2004-01-01
Bacterial surface structures such as capsules and adhesins are generally regarded as important virulence factors. Here we demonstrate that capsules block the function of the self-recognizing protein antigen 43 through physical shielding. The phenomenon is not restricted to Escherichia coli but can...
International Nuclear Information System (INIS)
Walton, Z.P.; Kam, J.T.
2002-01-01
The Engineered Barrier System (EBS) represents the system of human engineered barriers in the isolation of high-level radioactive waste in the proposed repository at Yucca Mountain. It is designed to complement and enhance the natural barriers to isolate and prevent the transport of radionuclides into the surrounding environment. The transport mechanism most frequently postulated for radionuclides is liquid water flux that has penetrated the EBS through corrosion breaches in the drip shield and waste packages (WP). A water flux-splitting model is used to predict flow through WP and drip shield breaches and is documented in the ''EBS Radionuclide Transport Abstraction''. A future revision of the ''EBS Radionuclide Transport Abstraction'' will be one component of the total system performance assessment--license application (TSPA-LA) for the Yucca Mountain repository. The flux-splitting model is conservative based on the following assumptions: (1) Drip impact occurs without a loss of water mass. (2) Dripping flux falls exactly at the crown of the drip shield as opposed to different locations on the curved surface, which will effect splashing and flow patterns. (3) The flux passing through a drip shield patch is proportional to the ratio of the length of the penetration in the axial direction to the total axial length of the drip shield. In this assumption all fluid that drips and flows from the drip shield crown toward a penetration will be collected if the axial locations of the source and patch coincide. (4) The potential for evaporation is ignored. Because of these conservatisms, the current version of the flux-splitting model is incapable of accounting for water that has been splashed from the impact location, the deviation of water paths (rivulets) from the axis of impact, and water loss due to evaporation. This paper will present the results of a series of breached drip shield tests used to collect empirical data for the initial validation and further
FCXSEC: multigroup cross-section libraries for nuclear fuel cycle shielding calculations
International Nuclear Information System (INIS)
Ford, W.E. III; Webster, C.C.; Diggs, B.R.; Pevey, R.E.; Croff, A.G.
1980-05-01
Starting with the pseudo-composition-independent VITAMIN-C cross-sectin library, composition-dependent fine-(171n-36γ) and broad-group (22n-21γ) self-shielded AMPX master, broad-group microscopic ANISN-formatted, and broad-group macroscopic ANISN-formatted cross-section libraries were generated to be used for nuclear fuel cycle shielding calculations. The specifications for the data and the procedure used to prepare the libraries are described
International Nuclear Information System (INIS)
Tzeng, Wen-Shian V.
1991-01-01
Electromagnetic interference (EMI) shielding materials are well known in the art in forms such as gaskets, caulking compounds, adhesives, coatings and the like for a variety of EMI shielding purposes. In the past, where high shielding performance is necessary, EMI shielding has tended to use silver particles or silver coated copper particles dispersed in a resin binder. More recently, aluminum core silver coated particles have been used to reduce costs while maintaining good electrical and physical properties. (author). 8 figs
Neutron shielding for a 252 Cf source
International Nuclear Information System (INIS)
Vega C, H.R.; Manzanares A, E.; Hernandez D, V.M.; Eduardo Gallego, Alfredo Lorente
2006-01-01
To determine the neutron shielding features of water-extended polyester a Monte Carlo study was carried out. Materials with low atomic number are predominantly used for neutron shielding because these materials effectively attenuate neutrons, mainly through inelastic collisions and absorption reactions. During the selection of materials to design a neutron shield, prompt gamma production as well as radionuclide production induced by neutron activation must be considered. In this investigation the Monte Carlo method was used to evaluate the performance of a water-extended polyester shield designed for the transportation, storage, and use of a 252 Cf isotopic neutron source. During calculations a detailed model for the 252 Cf and the shield was utilized. To compare the shielding features of water extended polyester, the calculations were also made for the bare 252 Cf in vacuum, air and the shield filled with water. For all cases the calculated neutron spectra was utilized to determine the ambient equivalent neutron dose at four sites around the shielding. In the case of water extended polyester and water shielding the calculations were extended to include the prompt gamma rays produced during neutron interactions, with this information the Kerma in air was calculated at the same locations where the ambient equivalent neutron dose was determined. (Author)
Magnetic shielding tests for MFTF-B neutral beamlines
International Nuclear Information System (INIS)
Kerns, J.; Fabyan, J.; Wood, R.; Koger, P.
1983-01-01
A test program to determine the effectiveness of various magnetic shielding designs for MFTF-B beamlines was established at Lawrence Livermore National Laboratory (LLNL). The proposed one-tenth-scale shielding-design models were tested in a uniform field produced by a Helmholtz coil pair. A similar technique was used for the MFTF source-injector assemblies, and the model test results were confirmed during the Technology Demonstration in 1982. The results of these tests on shielding designs for MFTF-B had an impact on the beamline design for MFTF-B. The iron-core magnet and finger assembly originally proposed were replaced by a simple, air-core, race-track-coil, bending magnet. Only the source injector needs to be magnetically shielded from the fields of approximately 400 gauss
Shielding calculations for NET
International Nuclear Information System (INIS)
Verschuur, K.A.; Hogenbirk, A.
1991-05-01
In the European Fusion Technology Programme there is only a small activity on research and development for fusion neutronics. Never-the-less, looking further than blanket design now, as ECN is getting involved in design of radiation shields for the coils and biological shields, it becomes apparent that fusion neutronics as a whole still needs substantial development. Existing exact codes for calculation of complex geometries like MCNP and DORT/TORT are put over the limits of their numerical capabilities, whilst approximate codes for complex geometries like FURNACE and MERCURE4 are put over the limits of their modelling capabilities. The main objective of this study is just to find out how far we can get with existing codes in obtaining reliable values for the radiation levels inside and outside the cryostat/shield during operation and after shut-down. Starting with a 1D torus model for preliminary parametric studies, more dimensional approximation of the torus or parts of it including the main heterogeneities should follow. Regular contacts with the NET-Team are kept, to be aware of main changes in NET design that might affect our calculation models. Work on the contract started 1 July 1990. The technical description of the contract is given. (author). 14 refs.; 4 figs.; 1 tab
Directory of Open Access Journals (Sweden)
About the Scythian Shields
2017-10-01
Full Text Available Shields played major role in the armament system of the Scythians. Made from organic materials, they are poorly traced on the materials of archaeological excavations. Besides, scaly surface of shields was often perceived in practice as the remnants of the scaly armor. E. V. Chernenko was able to discern the difference between shields’ scaly plates and armor scales. The top edge of the scales was bent inwards, and shield plates had a wire fixation. These observations let significantly increase the number of shields, found in the burial complexes of the Scythians. The comparison of archaeological materials and the images of Scythian warriors allow distinguishing the main forms of Scythian shields. All shields are divided into fencing shields and cover shields. The fencing shields include round wooden shields, reinforced with bronze sheet, and round moon-shaped shields with a notch at the top, with a metal scaly surface. They came to the Scythians under the Greek influence and are known in the monuments of the 4th century BC. Oval shields with scaly surface (back cover shields were used by the Scythian cavalry. They protected the rider in case of frontal attack, and moved back in case of maneuver or closein fighting. Scythian battle tactics were based on rapid approaching the enemy and throwing spears and further rapid withdrawal. Spears stuck in the shields of enemies, forcing them to drop the shields, uncover, and in this stage of the battle the archers attacked the disorganized ranks of the enemy. That was followed by the stage of close fight. Oval form of a wooden shield with leather covering was used by the Scythian infantry and spearmen. Rectangular shields, including wooden shields and the shields pleached from rods, represented a special category. The top of such shield was made of wood, and a pleached pad on leather basis was attached to it. This shield could be a reliable protection from arrows, but it could not protect against javelins
Dermody, Janine; Hanmer-Lloyd, Stuart; Koenig-Lewis, Nicole; Zhao, Anita Lifen
2015-01-01
In this paper, we respond to the call for more holistic and culturally diverse research to advance understanding of (non)sustainable consumption behaviour. Our conceptual model incorporates materialism, environmental concern, social consumption motivation, pro-environmental self-identity and sustainable consumption behaviours. This paper contributes to knowledge by examining the mediating role of pro-environmental self-identity to more fully explain consumers’ (non)sustainable consumption beh...
Shielding Design and Radiation Shielding Evaluation for LSDS System Facility
International Nuclear Information System (INIS)
Kim, Younggook; Kim, Jeongdong; Lee, Yongdeok
2015-01-01
As the system characteristics, the target in the spectrometer emits approximately 1012 neutrons/s. To efficiently shield the neutron, the shielding door designs are proposed for the LSDS system through a comparison of the direct shield and maze designs. Hence, to guarantee the radiation safety for the facility, the door design is a compulsory course of the development of the LSDS system. To improve the shielding rates, 250x250 covering structure was added as a subsidiary around the spectrometer. In this study, the evaluations of the suggested shielding designs were conducted using MCNP code. The suggested door design and covering structures can shield the neutron efficiently, thus all evaluations of all conditions are satisfied within the public dose limits. From the Monte Carlo code simulation, Resin(Indoor type) and Tungsten(Outdoor type) were selected as the shielding door materials. From a comparative evaluation of the door thickness, In and Out door thickness was selected 50 cm
Academic Self-Perceptions of Ability and Course Planning among Academically Advanced Students
Rudasill, Kathleen Moritz; Callahan, Carolyn M.
2010-01-01
The purpose of this study is to examine the contribution of gender to the academic self-perceptions of ability and related coursework plans for high school and college across academically advanced students. Participants were academically advanced students (N = 447) from grades 5 to 12. Findings revealed that (a) girls' self-perceptions of ability…
Optimal Magnetic Field Shielding Method by Metallic Sheets in Wireless Power Transfer System
Directory of Open Access Journals (Sweden)
Feng Wen
2016-09-01
Full Text Available To meet the regulations established to limit human exposure to time-varying electromagnetic fields (EMFs such as the International Committee on Non-Ionizing Radiation Protection (ICNIRP guidelines, thin metallic sheets are often used to shield magnetic field leakage in high power applications of wireless power transfer (WPT systems based on magnetic field coupling. However, the metals in the vicinity of the WPT coils cause the decrease of self and mutual inductances and increase of effective series resistance; as such, the electric performance including transmission power and the efficiency of the system is affected. With the research objective of further investigating excellent shielding effectiveness associated with system performance, the utilization of the optimal magnetic field shielding method by metallic sheets in magnetic field coupling WPT is carried out in this paper. The circuit and 3D Finite Element Analysis (FEA models are combined to predict the magnetic field distribution and electrical performance. Simulation and experiment results show that the method is very effective by obtaining the largest possible coupling coefficient of the WPT coils within the allowable range and then reducing the value nearest to and no smaller than the critical coupling coefficient via geometric unbroken metallic sheets. The optimal magnetic field shielding method which considers the system efficiency, transmission power, transmission distance, and system size is also achieved using the analytic hierarchy process (AHP. The results can benefit WPT by helping to achieve efficient energy transfer and safe use in metal shielded equipment.
Modelling the Influence of Shielding on Physical and Biological Organ Doses
Ballarini, Francesca; Ferrari, Alfredo; Ottolenghi, Andrea; Pelliccioni, Maurizio; Scannicchio, Domenico
2002-01-01
Distributions of "physical" and "biological" dose in different organs were calculated by coupling the FLUKA MC transport code with a geometrical human phantom inserted into a shielding box of variable shape, thickness and material. While the expression "physical dose" refers to the amount of deposited energy per unit mass (in Gy), "biological dose" was modelled with "Complex Lesions" (CL), clustered DNA strand breaks calculated in a previous work based on "event-by-event" track-structure simulations. The yields of complex lesions per cell and per unit dose were calculated for different radiation types and energies, and integrated into a version of FLUKA modified for this purpose, allowing us to estimate the effects of mixed fields. As an initial test simulation, the phantom was inserted into an aluminium parallelepiped and was isotropically irradiated with 500 MeV protons. Dose distributions were calculated for different values of the shielding thickness. The results were found to be organ-dependent. In most ...
APOLLO-2: An advanced transport code for LWRs
International Nuclear Information System (INIS)
Mathonniere, G.
1995-01-01
APOLLO-2 is a fully modular code in which each module corresponds to a specific task: access to the cross-sections libraries, creation of isotopes medium or mixtures, geometry definition, self-shielding calculations, computation of multigroup collision probabilities, flux solver, depletion calculations, transport-transport or transport-diffusion equivalence process, SN calculations, etc... Modules communicate exclusively by ''objects'' containing structured data, these objects are identified and handled by user's given names. Among the major improvements offered by APOLLO-2 the modelization of the self-shielding: it is possible now to deal with a great precision, checked versus Montecarlo calculations, a fuel rod divided into several concentric rings. So the total production of Plutonium is quite better estimated than before and its radial distribution may be predicted also with a good accuracy. Thanks to the versatility of the code some reference calculations and routine ones may be compared easily because only one parameter is changed; for example the self-shielding approximations are modified, the libraries or the flux solver being exactly the same. Other interesting features have been introduced in APOLLO-2: the new isotopes JEF.2 are available in 99 and 172 energy groups libraries, the surface leakage model improves the calculation of the control rod efficiency, the flux-current method allows faster calculations, the possibility of an automatic convergence checking during the depletion calculations coupled with fully automatic corrections, heterogeneous diffusion coefficients used for voiding analysis. 17 refs, 1 tab
International Nuclear Information System (INIS)
Sinitsa, V.V.
1984-11-01
The author gives a scheme for the calculation of the self-shielding factors in the unresolved resonance region using the GRUCON applied program package. This package is especially created to be used in the conversion of evaluated neutron cross-section data, as available in existing data libraries, into multigroup microscopic constants. A detailed description of the formulae and algorithms used in the programs is given. Some typical examples of calculation are considered and the results are compared with those of other authors. The calculation accuracy is better than 2%
Li, Ping
2016-01-13
To meet the electromagnetic interference regulation, the radiated emission from device under test such as electronic devices must be carefully manipulated and accurately characterized. Instead of resorting to the direct far-field measurement, in this paper, a novel approach is proposed to model the radiated emission from electronic devices placed in shielding enclosures by using the near electric field only. Based on the Schelkkunoff’s equivalence principle and Raleigh–Carson reciprocity theorem, only the tangential components of the electric field over the ventilation slots and apertures of the shielding enclosure are sufficient to obtain the radiated emissions outside the shielding box if the inside of the shielding enclosure was filled with perfectly electric conductor (PEC). In order to efficiently model wideband emission, the time-domain sampling scheme is employed. Due to the lack of analytical Green’s function for arbitrary PEC boxes, the radiated emission must be obtained via the full-wave numerical methods by considering the total radiated emission as the superposition between the direct radiation from the equivalent magnetic currents in free space and the scattered field generated by the PEC shielding box. In this study, the state-of-the-art discontinuous Galerkin time-domain (DGTD) method is utilized, which has the flexibility to model irregular geometries, keep high-order accuracy, and more importantly involves only local operations. For open-region problems, a hybridized DGTD and time-domain boundary integration method applied to rigorously truncate the computational domain. To validate the proposed approach, several representative examples are presented and compared with both analytical and numerical results.
International Nuclear Information System (INIS)
Tanaka, Shun-ichi; Sasamoto, Nobuo; Oka, Yoshiaki; Kawai, Masayoshi; Nakazawa, Masaharu.
1978-09-01
Shielding benchmark problems were prepared by the Working Group of Assessment of Shielding Experiments in the Research Comittee on Shielding Design of the Atomic Energy Society of Japan, and compiled by the Shielding Laboratory of Japan Atomic Energy Research Institute. Twenty-one kinds of shielding benchmark problems are presented for evaluating the calculational algorithm and the accuracy of computer codes based on the discrete ordinates method and the Monte Carlo method and for evaluating the nuclear data used in the codes. (author)
Mikell, Justin K; Klopp, Ann H; Price, Michael; Mourtada, Firas
2013-01-01
We sought to commission a gynecologic shielded colpostat analytic model provided from a treatment planning system (TPS) library. We have reported retrospectively the dosimetric impact of this applicator model in a cohort of patients. A commercial TPS with a grid-based Boltzmann solver (GBBS) was commissioned for (192)Ir high-dose-rate (HDR) brachytherapy for cervical cancer with stainless steel-shielded colpostats. Verification of the colpostat analytic model was verified using a radiograph and vendor schematics. MCNPX v2.6 Monte Carlo simulations were performed to compare dose distributions around the applicator in water with the TPS GBBS dose predictions. Retrospectively, the dosimetric impact was assessed over 24 cervical cancer patients' HDR plans. Applicator (TPS ID #AL13122005) shield dimensions were within 0.4 mm of the independent shield dimensions verification. GBBS profiles in planes bisecting the cap around the applicator agreed with Monte Carlo simulations within 2% at most locations; differing screw representations resulted in differences of up to 9%. For the retrospective study, the GBBS doses differed from TG-43 as follows (mean value ± standard deviation [min, max]): International Commission on Radiation units [ICRU]rectum (-8.4 ± 2.5% [-14.1, -4.1%]), ICRUbladder (-7.2 ± 3.6% [-15.7, -2.1%]), D2cc-rectum (-6.2 ± 2.6% [-11.9, -0.8%]), D2cc-sigmoid (-5.6 ± 2.6% [-9.3, -2.0%]), and D2cc-bladder (-3.4 ± 1.9% [-7.2, -1.1%]). As brachytherapy TPSs implement advanced model-based dose calculations, the analytic applicator models stored in TPSs should be independently validated before clinical use. For this cohort, clinically meaningful differences (>5%) from TG-43 were observed. Accurate dosimetric modeling of shielded applicators may help to refine organ toxicity studies. Copyright © 2013 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
Shielding Benchmark Computational Analysis
International Nuclear Information System (INIS)
Hunter, H.T.; Slater, C.O.; Holland, L.B.; Tracz, G.; Marshall, W.J.; Parsons, J.L.
2000-01-01
Over the past several decades, nuclear science has relied on experimental research to verify and validate information about shielding nuclear radiation for a variety of applications. These benchmarks are compared with results from computer code models and are useful for the development of more accurate cross-section libraries, computer code development of radiation transport modeling, and building accurate tests for miniature shielding mockups of new nuclear facilities. When documenting measurements, one must describe many parts of the experimental results to allow a complete computational analysis. Both old and new benchmark experiments, by any definition, must provide a sound basis for modeling more complex geometries required for quality assurance and cost savings in nuclear project development. Benchmarks may involve one or many materials and thicknesses, types of sources, and measurement techniques. In this paper the benchmark experiments of varying complexity are chosen to study the transport properties of some popular materials and thicknesses. These were analyzed using three-dimensional (3-D) models and continuous energy libraries of MCNP4B2, a Monte Carlo code developed at Los Alamos National Laboratory, New Mexico. A shielding benchmark library provided the experimental data and allowed a wide range of choices for source, geometry, and measurement data. The experimental data had often been used in previous analyses by reputable groups such as the Cross Section Evaluation Working Group (CSEWG) and the Organization for Economic Cooperation and Development/Nuclear Energy Agency Nuclear Science Committee (OECD/NEANSC)
Future directions in shielding methods and analysis
International Nuclear Information System (INIS)
Goldstein, H.
1987-01-01
Over the nearly half century history of shielding against reactor radiation, there has been a see-saw battle between theory and measurement. During that period the capability and accuracy of calculational methods have been enormously improved. The microscopic cross sections needed as input to the theoretical computations are now also known to adequate accuracy (with certain exceptions). Nonetheless, there remain substantial classes of shielding problems not yet accessible to satisfactory computational methods, particularly where three-dimensional geometries are involved. This paper discusses promising avenues to approach such problems, especially in the light of recent and expected advances in supercomputers. In particular, it seems that Monte Carlo methods should be much more advantageous in the new computer environment than they have been in the past
Shielding evaluation of moving bed onion irradiator by radiometry
International Nuclear Information System (INIS)
Venkataramani, R.; Sangurdekar, P.R.; Sarangapani, R.; Raipurkar, D.R.; Mehta, S.K.; Shastri, S.P.; Patil, K.B.; Bongirwar, D.R.
1994-01-01
A moving bed onion irradiator made from m.s. cladded lead slab shields designed to hold 20 kCi of 60 Co source was evaluated by radiometry with an 8 Ci 60 Co source from CRC-2 radiography camera. Some shielding losses in the irradiator noted by radiometry could be visualized by a thermocole model of the complex shielding assembly. These were rectified by appropriate lead filling. Significant shielding losses noted at cladding layer positions of slabs were attributed to lack of interlocking features in the slabs. These had to be rectified by provision of 3 TVL of additional all round shielding supplemented by local shielding at some positions. (author). 1 fig., 1 tab
Radiation shielding activities at the OECD/Nuclear Energy Agency
International Nuclear Information System (INIS)
Sartori, Enrico; Vaz, Pedro
2000-01-01
The OECD Nuclear Energy Agency (NEA) has devoted considerable effort over the years to radiation shielding issues. The issues are addressed through international working groups. These activities are carried out in close co-ordination and co-operation with the Radiation Safety Information Computational Center (RSICC). The areas of work include: basic nuclear data activities in support of radiation shielding, computer codes, shipping cask shielding applications, reactor pressure vessel dosimetry, shielding experiments database. The method of work includes organising international code comparison exercises and benchmark studies. Training courses on radiation shielding computer codes are organised regularly including hands-on experience in modelling skills. The scope of the activity covers mainly reactor shields and spent fuel transportation packages, but also fusion neutronics and in particular shielding of accelerators and irradiation facilities. (author)
Derradji, Mehdi; Zegaoui, Abdeldjalil; Xu, Yi-Le; Wang, An-ran; Dayo, Abdul Qadeer; Wang, Jun; Liu, Wen-bin; Liu, Yu-Guang; Khiari, Karim
2018-04-01
The phthalonitrile resins have claimed the leading place in the field of high performance polymers thanks to their combination of outstanding properties. The present work explores for the first time the gamma rays radiation resistance and shielding efficiency of the phthalonitrile resins and its related tungsten-reinforced nanocomposites. The primary goal of this research is to define the basic behavior of the phthalonitrile resins under highly ionizing gamma rays. The obtained results confirmed that the neat phthalonitrile resins can resist absorbed doses as high as 200 kGy. Meanwhile, the remarkable shielding efficiency of the phthalonitrile polymers was confirmed to be easily improved by preparing lead-free nanocomposites. In fact, the gamma rays screening ratio reached the exceptional value of 42% for the nanocomposites of 50 wt% of nano-tungsten loading. Thus, this study confirms that the remarkable performances of the phthalonitrile resins are not limited to the thermal and mechanical properties and can be extended to the gamma rays radiation and shielding resistances.
Contaminant deposition building shielding factors for US residential structures.
Dickson, Elijah; Hamby, David; Eckerman, Keith
2017-10-10
This paper presents validated building shielding factors designed for contemporary US housing-stock under an idealized, yet realistic, exposure scenario from contaminant deposition on the roof and surrounding surfaces. The building shielding factors are intended for use in emergency planning and level three probabilistic risk assessments for a variety of postulated radiological events in which a realistic assessment is necessary to better understand the potential risks for accident mitigation and emergency response planning. Factors are calculated from detailed computational housing-units models using the general-purpose Monte Carlo N-Particle computational code, MCNP5, and are benchmarked from a series of narrow- and broad-beam measurements analyzing the shielding effectiveness of ten common general-purpose construction materials and ten shielding models representing the primary weather barriers (walls and roofs) of likely US housing-stock. Each model was designed to scale based on common residential construction practices and include, to the extent practical, all structurally significant components important for shielding against ionizing radiation. Calculations were performed for floor-specific locations from contaminant deposition on the roof and surrounding ground as well as for computing a weighted-average representative building shielding factor for single- and multi-story detached homes, both with and without basement as well for single-wide manufactured housing-unit. © 2017 IOP Publishing Ltd.
Contaminant deposition building shielding factors for US residential structures
International Nuclear Information System (INIS)
Dickson, E D; Hamby, D M; Eckerman, K F
2015-01-01
This paper presents validated building shielding factors designed for contemporary US housing-stock under an idealized, yet realistic, exposure scenario from contaminant deposition on the roof and surrounding surfaces. The building shielding factors are intended for use in emergency planning and level three probabilistic risk assessments for a variety of postulated radiological events in which a realistic assessment is necessary to better understand the potential risks for accident mitigation and emergency response planning. Factors are calculated from detailed computational housing-units models using the general-purpose Monte Carlo N-Particle computational code, MCNP5, and are benchmarked from a series of narrow- and broad-beam measurements analyzing the shielding effectiveness of ten common general-purpose construction materials and ten shielding models representing the primary weather barriers (walls and roofs) of likely US housing-stock. Each model was designed to scale based on common residential construction practices and include, to the extent practical, all structurally significant components important for shielding against ionizing radiation. Calculations were performed for floor-specific locations from contaminant deposition on the roof and surrounding ground as well as for computing a weighted-average representative building shielding factor for single- and multi-story detached homes, both with and without basement as well for single-wide manufactured housing-unit. (paper)
Cloud immersion building shielding factors for US residential structures
International Nuclear Information System (INIS)
Dickson, E D; Hamby, D M
2014-01-01
This paper presents validated building shielding factors designed for contemporary US housing-stock under an idealized, yet realistic, exposure scenario within a semi-infinite cloud of radioactive material. The building shielding factors are intended for use in emergency planning and level three probabilistic risk assessments for a variety of postulated radiological events in which a realistic assessment is necessary to better understand the potential risks for accident mitigation and emergency response planning. Factors are calculated from detailed computational housing-units models using the general-purpose Monte Carlo N-Particle computational code, MCNP5, and are benchmarked from a series of narrow- and broad-beam measurements analyzing the shielding effectiveness of ten common general-purpose construction materials and ten shielding models representing the primary weather barriers (walls and roofs) of likely US housing-stock. Each model was designed to scale based on common residential construction practices and include, to the extent practical, all structurally significant components important for shielding against ionizing radiation. Calculations were performed for floor-specific locations as well as for computing a weighted-average representative building shielding factor for single- and multi-story detached homes, both with and without basement, as well for single-wide manufactured housing-units. (paper)
Effect of metal shielding on a wireless power transfer system
Li, Jiacheng; Huang, Xueliang; Chen, Chen; Tan, Linlin; Wang, Wei; Guo, Jinpeng
2017-05-01
In this paper, the effect of non-ferromagnetic metal shielding (NFMS) material on the resonator of wireless power transfer (WPT) is studied by modeling, simulation and experimental analysis. And, the effect of NFMS material on the power transfer efficiency (PTE) of WPT systems is investigated by circuit model. Meanwhile, the effect of ferromagnetic metal shielding material on the PTE of WPT systems is analyzed through simulation. A double layer metal shield structure is designed. Experimental results demonstrate that by applying the novel double layer metal shielding method, the system PTE increases significantly while the electromagnetic field of WPT systems declines dramatically.
Heating profiles on ICRF antenna Faraday shields
International Nuclear Information System (INIS)
Taylor, D.J.; Baity, F.W.; Hahs, C.L. Riemer, B.W.; Ryan, D.M.; Williamson, D.E.
1992-01-01
Poor definition of the heating profiles that occur during normal operation of Faraday shields for ion cyclotron resonant frequency (ICRF) antennas has complicated the mechanical design of ICRF system components. This paper reports that at Oak Ridge National Laboratory (ORNL), Faraday shield analysis is being used in defining rf heating profiles. In recent numerical analyses of proposed hardware for the Burning Plasma Experiment (BPX) and DIII-D, rf magnetic fields at Faraday shield surfaces were calculated, providing realistic predictions of the induced skin currents flowing on the shield elements and the resulting dissipated power profile. Detailed measurements on mock-ups of the Faraday shields for DIII-D and the Tokamak Fusion Test Reactor (TFTR) confirmed the predicted magnetic field distributions. A conceptual design for an uncooled Faraday shield for the BPX ion cyclotron resonance heating (ICRH) antenna, which should withstand the proposed long-pulse operation, has been completed. The analytical effort is described in detail, with emphasis on the design work for the BPX ICRH antenna conceptual design and for the replacement Faraday shield for the DIII-D FWCD antenna. Results of analyses are shown, and configuration issues involved in component modeling are discussed
Activation of the concrete in the bio shield of ITER
International Nuclear Information System (INIS)
Kalcheva, S.
2005-02-01
Calculations of neutron spectra in different parts of the tokamak building of ITER are performed. A computational geometry model of the tokamak building is prepared using MCNP-4C. The model includes adequate material composition and geometry description of the main parts of the tokamak for PPCS plant model A: toroidal field coils, vacuum vessel, shield, blanket structure, first wall, divertor, 14.1 MeV neutron source. The design and the dimensions of the bio shield are taken from the current ITER design. MCNP calculations of the neutron spectra in the bio shield (concrete) of ITER are performed, using the neutron spectra in TF coils calculated at UKAEA as external neutron source. The neutron spectra in the concrete calculated by MCNP are used as input data in the code EASY99 for estimations of the activation of the concrete in the bio shield around the tokamak. The time evolutions of the maximum (in the bio shield floor) and minimum (in the bio shield side walls) specific activity (Bq/kg) and dose rate (Sv/h.) of the main dominant nuclides in the concrete are evaluated and compared for 3 different concrete types, used as biological shield in the PWR and BR3 reactors. (author)
Self-shielding factors for TLD-600 and TLD-100 in an isotropic flux of thermal neutrons
International Nuclear Information System (INIS)
Horowitz, Y.S.; Dubi, A.; Ben Shahar, B.
1976-01-01
The applications of lithium fluoride thermoluminescent dosemeters in mixed n-γ environments, and the dependence of LiF-TL on linear energy transfer are both topics of current interest. Monte Carlo calculations have therefore been carried out to determine the thermal neutron absorption probability (and consequently the self-shielding factor) for an isotropic flux of neutrons impinging on different sized cylindrical samples of LiF TLD-100 and TLD-600. The calculations were performed for cylinders of radius up to 10 cm and heights of 0.1 to 1.5 cm. The Monte Carlo results were found to be significantly different from the analytic calculations for infinitely long cylinders, but, as expected, converged to the same value for (r/h) << 1. (U.K.)
Electromagnetic shielding formulae
International Nuclear Information System (INIS)
Dahlberg, E.
1979-02-01
This addendum to an earlier collection of electromagnetic shielding formulae (TRITA-EPP-75-27) contains simple transfer matrices suitable for calculating the quasistatic shielding efficiency for multiple transverse-field and axial-field cylindrical and spherical shields, as well as for estimating leakage fields from long coaxial cables and the normal-incidence transmission of a plane wave through a multiple plane shield. The differences and similarities between these cases are illustrated by means of equivalent circuits and transmission line analogies. The addendum also includes a discussion of a possible heuristic improvement of some shielding formulae. (author)
nmr spectroscopic study and dft calculations of giao nmr shieldings
African Journals Online (AJOL)
Preferred Customer
3Department of Physics, Arts and Science Faculty, Dumlupinar University, Kütahya, ... 1H, 13C NMR chemical shifts and 1JCH coupling constants of .... then estimated using the corresponding TMS shieldings calculated in advance at the same.
DEFF Research Database (Denmark)
Fog, Lotte S; Cormack, John
2010-01-01
Given that the financial cost of shielding PET/CT suites can be substantial, it has become increasingly important to be able to accurately assess the thickness of shielding required for barriers and whether it is necessary to extend such shielding all the way to the ceiling. The overall shielding...... requirement for a PET/CT installation must take into account both 511 keV gamma ray emissions from PET scans and lower energy x-ray scatter from CT scans. This paper deals with the overall impact of emissions from both modalities. Radiation exposure from both scatter over shielding barriers as well...... as transmission through these barriers is taken into account. A series of simulations of the dose received by a person positioned behind a shielding barrier in a typical PET/CT scanning suite were carried out using both Monte Carlo and analytical models. The transmission through lead barriers was found to be very...
International Nuclear Information System (INIS)
Ganesan, S.; Gopalakrishnan, V.; Ramanadhan, M.M.; Cullen, D.E.
1988-01-01
Verification results for Doppler broadening and self-shielding are presented. One of the important results presented is that the original SIGMA1 method of numerical Doppler broadening has now been demonstrated to be inaccurate and not capable of producing results to within required accuracies. Fortunately, due to this study, the SIGMA1 method has been significantly improved and the new SIGMA1 is now capable of producing results to within required accuracies. Although this paper presents results based upon using only one code system, it is important to realize that the original SIGMA1 method is presently used in many cross-section processing code systems; the results of this paper indicate that unless these other code systems are updated to include the new SIGMA1 method, the results produced by these code systems could be very inaccurate. The objectives of the IAEA nuclear data processing code verification project are reviewed as well as the requirements for the accuracy of calculation of Doppler coefficients and the present status of these calculations. The initial results of Doppler broadening and self-shielding calculations are presented and the inconsistency of the results which led to the discovery of errors in the original SIGMA1 method of Doppler broadening are pointed out. Analysis of the errors found and improvements in the SIGMA1 method are presented. Improved results are presented in order to demonstrate that the new SIGMA1 method can produce results within required accuracies. Guidelines are presented to limit the uncertainty introduced due to cross-section processing in order to balance available computer resources to accuracy requirements. Finally cross-section processing code users are invited to participate in the IAEA processing code verification project in order to verify the accuracy of their calculated results. (author)
Occupation as marker of self:occupation in relation to self among people with advanced cancer
DEFF Research Database (Denmark)
Mærsk, Jesper Larsen; Johannessen, Helle; la Cour, Karen
2018-01-01
cancer. Grounded theory guided the collection and analysis of data. RESULTS: 'Occupation as marker of self' was identified as the core category. Occupations served as markers of the participants' self (1) by mirroring their abilities and positioning of their self in the illness trajectory; and (2......) as means of expressing their self. The core category provided explanations about how the participants' experiences of occupation influenced their self-perceptions, as explained in the sub-categories 'defining the self through occupation' and 'reassessing self and accepting limitations'. CONCLUSIONS......Abstract BACKGROUND: Living with advanced cancer can have a profound impact on the person's self. A person's self is influenced by various aspects of daily life, including engagement in occupation. From an occupational perspective, little research has been done to explore how the self of people...
Advanced transport modeling of toroidal plasmas with transport barriers
International Nuclear Information System (INIS)
Fukuyama, A.; Murakami, S.; Honda, M.; Izumi, Y.; Yagi, M.; Nakajima, N.; Nakamura, Y.; Ozeki, T.
2005-01-01
Transport modeling of toroidal plasmas is one of the most important issue to predict time evolution of burning plasmas and to develop control schemes in reactor plasmas. In order to describe the plasma rotation and rapid transition self-consistently, we have developed an advanced scheme of transport modeling based on dynamical transport equation and applied it to the analysis of transport barrier formation. First we propose a new transport model and examine its behavior by the use of conventional diffusive transport equation. This model includes the electrostatic toroidal ITG mode and the electromagnetic ballooning mode and successfully describes the formation of internal transport barriers. Then the dynamical transport equation is introduced to describe the plasma rotation and the radial electric field self-consistently. The formation of edge transport barriers is systematically studied and compared with experimental observations. The possibility of kinetic transport modeling in velocity space is also examined. Finally the modular structure of integrated modeling code for tokamaks and helical systems is discussed. (author)
Energy Technology Data Exchange (ETDEWEB)
NONE
2006-09-15
Interaction between chock shield supports, the most popular powered supports in Indian longwall mines, and surrounding coal measure strata is analyzed using finite element models. Thickness and material properties of the main roof, the immediate roof and the coal seam are varied to simulate various geological conditions of Indian coal measure strata. Contact/gap elements are inserted in between the main roof and overburden layer to allow strata separation. Nonlinear material properties are applied with plastic corrections based on Drucker-Prager yield criterion. This paper illustrates effects of lithological variations on shield load, abutment stress, yield zone and longwall face convergence.
Shielding member for thermonuclear device
Energy Technology Data Exchange (ETDEWEB)
Onozuka, Masanori
1997-06-30
In a thermonuclear device for shielding fast neutrons by shielding members disposed in a shielding vessel (vacuum vessel and structures such as a blanket disposed in the vacuum vessel), the shielding member comprises a large number of shielding wires formed fine and short so as to have elasticity. The shielding wires are sealed in a shielding vessel together with water, and when the width of the shielding vessel is changed, the shielding wires follow after the change of the width while elastically deforming in the shielding vessel, so that great stress and deformation are not formed thereby enabling to improve reliability. In addition, the length, the diameter and the shape of each of the shielding wires can be selected in accordance with the shielding space of the shielding vessel. Even if the shape of the shielding vessel is complicated, the shielding wires can be inserted easily. Accordingly, the filling rate of the shielding members can be changed easily. It can be produced more easily compared with a conventional spherical pebbles. It can be produced more easily than existent spherical shielding pebbles thereby enabling to reduce the production cost. (N.H.)
Analysis of ferromagnetic shielding of the ITER NBI
International Nuclear Information System (INIS)
Roccella, M.; Lucca, F.; Roccella, R.; Cocilovo, V.; Ramogida, G.; Portone, A.; Tanga, A.; Formisano, A.; Martone, R.
2006-01-01
In ITER two heating and one diagnostic Neutral Beam Injectors (NBIs) are foreseen [P. L. Mondino et al., ''ITER neutral beam system '', Nucl. Fus., vol. 40, p. 501 (2000)]. Inside these components there are very stringent limits on the magnetic field (the flux density must be below some Gauss (G) along the ion path and below 20 G in the neutralizing region). To achieve these performances in an environment with high stray field due to the plasma and the poloidal field coils, both passive and active shielding systems are foreseen. The present design of the Magnetic Field Reduction System (MFRS) is made of seven active coils and of a box surrounding the NBI region, consisting of ferromagnetic plates 15 cm thick. The electromagnetic analysis of the effectiveness of these shields has been performed by a full 3D FEM model using the ANSYS code. To perform the FEM modeling of the component special care has been used to face the particular geometrical features of the component (a box of about 15 x 5 x 5 m vs. a ferromagnetic layer of only 15 cm thick). To insert an adequate number of FEM elements (at least 5) in the thickness of the ferromagnetic layer, without a prohibitive increase in the total FEM elements number, a particular modeling approach (a sort of '' Chinese boxes '' technique) has been developed. Due to this technique the FEM model enclosing the ferromagnetic box results completely independent on the fine FEM structure inside the shielding layer. It has been even possible, using this technique, introducing a thin (below 1 cm thick) slot all through the shielding plates, without perturbing the rest of the model. This slot has been used to analyze the effects of possible manufacturing lacks on the residual magnetic field inside the component. This technique has allowed the use of only structured meshes made by brick elements, much more accurate than the tetra elements, needed in the usual free meshing techniques. To have the possibility of changing the shielding
Rodgers, Arthur J.; Walter, William R.; Mellors, Robert J.; Al-Amri, Abdullah M. S.; Zhang, Yu-Shen
1999-09-01
Regional seismic waveforms reveal significant differences in the structure of the Arabian Shield and the Arabian Platform. We estimate lithospheric velocity structure by modelling regional waveforms recorded by the 1995-1997 Saudi Arabian Temporary Broadband Deployment using a grid search scheme. We employ a new method whereby we narrow the waveform modelling grid search by first fitting the fundamental mode Love and Rayleigh wave group velocities. The group velocities constrain the average crustal thickness and velocities as well as the crustal velocity gradients. Because the group velocity fitting is computationally much faster than the synthetic seismogram calculation this method allows us to determine good average starting models quickly. Waveform fits of the Pn and Sn body wave arrivals constrain the mantle velocities. The resulting lithospheric structures indicate that the Arabian Platform has an average crustal thickness of 40 km, with relatively low crustal velocities (average crustal P- and S-wave velocities of 6.07 and 3.50 km s^-1 , respectively) without a strong velocity gradient. The Moho is shallower (36 km) and crustal velocities are 6 per cent higher (with a velocity increase with depth) for the Arabian Shield. Fast crustal velocities of the Arabian Shield result from a predominantly mafic composition in the lower crust. Lower velocities in the Arabian Platform crust indicate a bulk felsic composition, consistent with orogenesis of this former active margin. P- and S-wave velocities immediately below the Moho are slower in the Arabian Shield than in the Arabian Platform (7.9 and 4.30 km s^-1 , and 8.10 and 4.55 km s^-1 , respectively). This indicates that the Poisson's ratios for the uppermost mantle of the Arabian Shield and Platform are 0.29 and 0.27, respectively. The lower mantle velocities and higher Poisson's ratio beneath the Arabian Shield probably arise from a partially molten mantle associated with Red Sea spreading and continental
Neutron shielding for a {sup 252} Cf source
Energy Technology Data Exchange (ETDEWEB)
Vega C, H.R.; Manzanares A, E.; Hernandez D, V.M. [Unidades Academicas de Estudios Nucleares e Ingenieria Electrica, Universidad Autonoma de Zacatecas, C. Cipres 10, Fracc. La Penuela, 98068 Zacatecas (Mexico); Eduardo Gallego, Alfredo Lorente [Depto. de Ingenieria Nuclear, ETS Ingenieros Industriales, Universidad Politecnica de Madrid, C. Jose Gutierrez Abascal 2, 28006 Madrid (Spain)]. e-mail: fermineutron@yahoo.com
2006-07-01
To determine the neutron shielding features of water-extended polyester a Monte Carlo study was carried out. Materials with low atomic number are predominantly used for neutron shielding because these materials effectively attenuate neutrons, mainly through inelastic collisions and absorption reactions. During the selection of materials to design a neutron shield, prompt gamma production as well as radionuclide production induced by neutron activation must be considered. In this investigation the Monte Carlo method was used to evaluate the performance of a water-extended polyester shield designed for the transportation, storage, and use of a {sup 252}Cf isotopic neutron source. During calculations a detailed model for the {sup 252}Cf and the shield was utilized. To compare the shielding features of water extended polyester, the calculations were also made for the bare {sup 252}Cf in vacuum, air and the shield filled with water. For all cases the calculated neutron spectra was utilized to determine the ambient equivalent neutron dose at four sites around the shielding. In the case of water extended polyester and water shielding the calculations were extended to include the prompt gamma rays produced during neutron interactions, with this information the Kerma in air was calculated at the same locations where the ambient equivalent neutron dose was determined. (Author)
Effect of metal shielding on a wireless power transfer system
Directory of Open Access Journals (Sweden)
Jiacheng Li
2017-05-01
Full Text Available In this paper, the effect of non-ferromagnetic metal shielding (NFMS material on the resonator of wireless power transfer (WPT is studied by modeling, simulation and experimental analysis. And, the effect of NFMS material on the power transfer efficiency (PTE of WPT systems is investigated by circuit model. Meanwhile, the effect of ferromagnetic metal shielding material on the PTE of WPT systems is analyzed through simulation. A double layer metal shield structure is designed. Experimental results demonstrate that by applying the novel double layer metal shielding method, the system PTE increases significantly while the electromagnetic field of WPT systems declines dramatically.
Electron structure of atoms in laser plasma: The Debye shielding model
International Nuclear Information System (INIS)
Sako, Tokuei; Okutsu, Hiroshi; Yamanouchi, Kaoru
2005-01-01
The electronic structure and the energy spectra of multielectron atoms in laser plasmas are examined by the Debye shielding model. The effect of the plasma environment on the electrons bound in an atom is taken into account by introducing the screened Coulomb-type potentials into the electronic Hamiltonian of an atom in place of the standard nuclear attraction and electron repulsion potentials. The capabilities of this new Hamiltonian are demonstrated for He and Li in laser plasmas. (author)
Why do mothers use nipple shields and how does this influence duration of exclusive breastfeeding?
DEFF Research Database (Denmark)
Kronborg, Hanne; Foverskov, Else; Nilsson, Ingrid
2017-01-01
with introducing nipple shields were lower- gestational age and birthweight. The use of nipple shields was furthermore found to be associated with a threefold increased risk of earlier cessation of exclusive breastfeeding: among primiparae odds ratio = 3.80 (confidence interval 2.61–5.53); among multiparae odds......The present study addressed the contentious discussions about the benefits and risks of nipple shield use. The objective was to explore self-reported reasons for using a nipple shield and examine associations pertaining to the mother, the infant and duration of breastfeeding. Data were collected...... breastfeeding period. Primiparae used nipple shields more often than multiparae, and early breastfeeding problems as well as background factors like lower age, education and higher body mass index were associated with a higher likelihood of using nipple shields. Characteristics of infants associated...
A contribution to shielding effectiveness analysis of shielded tents
Directory of Open Access Journals (Sweden)
Vranić Zoran M.
2004-01-01
Full Text Available An analysis of shielding effectiveness (SE of the shielded tents made of the metallised fabrics is given. First, two electromagnetic characteristic fundamental for coupling through electrically thin shield, the skin depth break frequency and the surface resistance or transfer impedance, is defined and analyzed. Then, the transfer function and the SE are analyzed regarding to the frequency range of interest to the Electromagnetic Compatibility (EMC Community.
International Nuclear Information System (INIS)
Wuerz, H.; Arkhipov, N.I.; Bakhtin, V.P.; Konkashbaev, I.; Landman, I.; Safronov, V.M.; Toporkov, D.A.; Zhitlukhin, A.M.
1995-01-01
The high divertor heat load during a tokamak plasma disruption results in sudden evaporation of a thin layer of divertor plate material, which acts as vapor shield and protects the target from further excessive evaporation. Formation and effectiveness of the vapor shield are theoretically modeled and are experimentally analyzed at the 2MK-200 facility under conditions simulating the thermal quench phase of ITER tokamak plasma disruptions. ((orig.))
Shielding in ungated field emitter arrays
Energy Technology Data Exchange (ETDEWEB)
Harris, J. R. [U.S. Navy Reserve, Navy Operational Support Center New Orleans, New Orleans, Louisiana 70143 (United States); Jensen, K. L. [Code 6854, Naval Research Laboratory, Washington, D.C. 20375 (United States); Shiffler, D. A. [Directed Energy Directorate, Air Force Research Laboratory, Albuquerque, New Mexico 87117 (United States); Petillo, J. J. [Leidos, Billerica, Massachusetts 01821 (United States)
2015-05-18
Cathodes consisting of arrays of high aspect ratio field emitters are of great interest as sources of electron beams for vacuum electronic devices. The desire for high currents and current densities drives the cathode designer towards a denser array, but for ungated emitters, denser arrays also lead to increased shielding, in which the field enhancement factor β of each emitter is reduced due to the presence of the other emitters in the array. To facilitate the study of these arrays, we have developed a method for modeling high aspect ratio emitters using tapered dipole line charges. This method can be used to investigate proximity effects from similar emitters an arbitrary distance away and is much less computationally demanding than competing simulation approaches. Here, we introduce this method and use it to study shielding as a function of array geometry. Emitters with aspect ratios of 10{sup 2}–10{sup 4} are modeled, and the shielding-induced reduction in β is considered as a function of tip-to-tip spacing for emitter pairs and for large arrays with triangular and square unit cells. Shielding is found to be negligible when the emitter spacing is greater than the emitter height for the two-emitter array, or about 2.5 times the emitter height in the large arrays, in agreement with previously published results. Because the onset of shielding occurs at virtually the same emitter spacing in the square and triangular arrays, the triangular array is preferred for its higher emitter density at a given emitter spacing. The primary contribution to shielding in large arrays is found to come from emitters within a distance of three times the unit cell spacing for both square and triangular arrays.
Transparent fast neutron shielding material and shielding method
International Nuclear Information System (INIS)
Nashimoto, Tetsuji; Katase, Haruhisa.
1993-01-01
Polyisobutylene having a viscosity average molecular weight of 20,000 to 80,000 and a hydrogen atom density of greater than 7.0 x 10 22 /cm 3 is used as a fast neutron shielding material. The shielding material is excellent in the shielding performance against fast neutrons, and there is no worry of leakage even when holes should be formed to a vessel. Further, it is excellent in fabricability, relatively safe even upon occurrence of fire and, in addition, it is transparent to enable to observe contents easily. (T.M.)
Electromagnetically shielded building
Energy Technology Data Exchange (ETDEWEB)
Takahashi, T; Nakamura, M; Yabana, Y; Ishikawa, T; Nagata, K
1992-04-21
This invention relates to a building having an electromagnetic shield structure well-suited for application to an information network system utilizing electromagnetic waves, and more particularly to an electromagnetically shielded building for enhancing the electromagnetic shielding performance of an external wall. 6 figs.
Electromagnetically shielded building
International Nuclear Information System (INIS)
Takahashi, T.; Nakamura, M.; Yabana, Y.; Ishikawa, T.; Nagata, K.
1992-01-01
This invention relates to a building having an electromagnetic shield structure well-suited for application to an information network system utilizing electromagnetic waves, and more particularly to an electromagnetically shielded building for enhancing the electromagnetic shielding performance of an external wall. 6 figs
International Nuclear Information System (INIS)
Kunishima, Shigeru.
1990-01-01
The radiation shielding concretes comprise water, cement, fine aggregates consisting of serpentines and blown mist slags, coarse aggregates consisting of serpentines and kneading materials. Since serpentines containing a relatively great amount of water of crystallization in rocks as coarse aggregates and fine aggregates, the hydrogen content in the radiation shielding concretes is increased and the neutron shielding effect is improved. In addition, since serpentines are added as the fine aggregates and blown mists slags of a great specific gravity are used, the specific gravity of the shielding concretes is increased to improve the γ-ray shielding effect. Further, by the use of the kneading material having a water reducing effect and fluidizing effect, and by the bearing effect of the spherical blown mist slags used as the fine aggregates, concrete fluidity can be increased. Accordingly, workability of the radiation shielding concretes can be improved. (T.M.)
Comparison of calculational methods for liquid metal reactor shields
International Nuclear Information System (INIS)
Carter, L.L.; Moore, F.S.; Morford, R.J.; Mann, F.M.
1985-09-01
A one-dimensional comparison is made between Monte Carlo (MCNP), discrete ordinances (ANISN), and diffusion theory (MlDX) calculations of neutron flux and radiation damage from the core of the Fast Flux Test Facility (FFTF) out to the reactor vessel. Diffusion theory was found to be reasonably accurate for the calculation of both total flux and radiation damage. However, for large distances from the core, the calculated flux at very high energies is low by an order of magnitude or more when the diffusion theory is used. Particular emphasis was placed in this study on the generation of multitable cross sections for use in discrete ordinates codes that are self-shielded, consistent with the self-shielding employed in the generation of cross sections for use with diffusion theory. The Monte Carlo calculation, with a pointwise representation of the cross sections, was used as the benchmark for determining the limitations of the other two calculational methods. 12 refs., 33 figs
Shielding augmentation of roll-on shield from NAPS to Kaiga-2
International Nuclear Information System (INIS)
Pradhan, A.S.; Kumar, A.N.
2000-01-01
Extensive radiation field surveys were conducted in NAPS and KAPS reactor buildings as a part of commissioning checks on radiation shielding. During such surveys, dose rate higher than the expected values were noticed in fuelling machine service areas. A movable shield, separating high field area fuelling machine vault and low field area fuelling machine service area, known as roll-on shield was identified as one of the causes of high field in fuelling machine service area along with weaker end-shield. This paper discusses systematic approach adopted in bringing down the dose rates in fuelling machine service area by augmentation of roll-on shield. (author)
Analytical model for relativistic corrections to the nuclear magnetic shielding constant in atoms
International Nuclear Information System (INIS)
Romero, Rodolfo H.; Gomez, Sergio S.
2006-01-01
We present a simple analytical model for calculating and rationalizing the main relativistic corrections to the nuclear magnetic shielding constant in atoms. It provides good estimates for those corrections and their trends, in reasonable agreement with accurate four-component calculations and perturbation methods. The origin of the effects in deep core atomic orbitals is manifestly shown
Analytical model for relativistic corrections to the nuclear magnetic shielding constant in atoms
Energy Technology Data Exchange (ETDEWEB)
Romero, Rodolfo H. [Facultad de Ciencias Exactas, Universidad Nacional del Nordeste, Avenida Libertad 5500 (3400), Corrientes (Argentina)]. E-mail: rhromero@exa.unne.edu.ar; Gomez, Sergio S. [Facultad de Ciencias Exactas, Universidad Nacional del Nordeste, Avenida Libertad 5500 (3400), Corrientes (Argentina)
2006-04-24
We present a simple analytical model for calculating and rationalizing the main relativistic corrections to the nuclear magnetic shielding constant in atoms. It provides good estimates for those corrections and their trends, in reasonable agreement with accurate four-component calculations and perturbation methods. The origin of the effects in deep core atomic orbitals is manifestly shown.
Hydrogen-Induced Cracking of the Drip Shield
International Nuclear Information System (INIS)
F. Hua
2004-01-01
Hydrogen-induced cracking is characterized by the decreased ductility and fracture toughness of a material due to the absorption of atomic hydrogen in the metal crystal lattice. Corrosion is the source of hydrogen generation. For the current design of the engineered barrier without backfill, hydrogen-induced cracking may be a concern because the titanium drip shield can be galvanically coupled to rock bolts (or wire mesh), which may fall onto the drip shield, thereby creating conditions for hydrogen production by electrochemical reaction. The purpose of this report is to analyze whether the drip shield will fail by hydrogen-induced cracking under repository conditions within 10,000 years after emplacement. Hydrogen-induced cracking is a scenario of premature failure of the drip shield. This report develops a realistic model to assess the form of hydrogen-induced cracking degradation of the drip shield under the hydrogen-induced cracking. The scope of this work covers the evaluation of hydrogen absorbed due to general corrosion and galvanic coupling to less noble metals (e.g., Stainless Steel Type 316 and carbon steels) under the repository conditions during the 10,000-year regulatory period after emplacement and whether the absorbed hydrogen content will exceed the critical hydrogen concentration value, above which the hydrogen-induced cracking is assumed to occur. This report also provides the basis for excluding the features, events, and processes (FEPs) related to hydrogen-induced cracking of the drip shield with particular emphasis on FEP 2.1.03.04.OB, hydride cracking of drip shields (DTN: M00407SEPFEPLA.000 [DIRS 170760]). This report is prepared according to ''Technical Work Plan (TWP) for: Regulatory Integration Modeling and Analysis of the Waste Form and Waste Package'' (BSC 2004 [DIRS 169944])
International Nuclear Information System (INIS)
Diop, C.M'B.
1984-01-01
This thesis presents a global shielding calculation scheme for neutron and gamma rays arising from the Tokamak TORE SUPRA fusion device, in which a deuterium plasma is used. To study the shield parameters we have elabored a important chaining of neutron and gamma transport codes, TRIPOLI, ANISN, MERCURE 4, allowing to evaluate the radial and skyshine components of the dose rate behind the concrete shield. The study of thermonuclear neutron activation is fundamental to define a tokamak exploitation strategy. For this, two formalisme have been developed. They are based on a modelization of the activation reaction rates according to TRIPOLI, ANISN, and MERCURE 4 codes capabilities. The first one calculates, in one dimensional geometry, the desactivation gamma dose rate inside the vacuum chamber. The second one is a tridimensional model which determines the spatial variation of the gamma dose rate in the machine room. The problem of the existence of runaway electrons and associated secondaries radiations, bremsstrahlung gamma rays particularly, is approched. The results which are presented have contributed to define the parameters of the concrete shield and a strategy for TORE SUPRA Tokamak exploitation [fr
International Nuclear Information System (INIS)
Wuerz, H.; Arkhipov, N.I.; Bakhin, V.P.; Goel, B.; Hoebel, W.; Konkashbaev, I.; Landman, I.; Piazza, G.; Safronov, V.M.; Sherbakov, A.R.; Toporkov, D.A.; Zhitlukhin, A.M.
1994-01-01
The high divertor heat load during a tokamak plasma disruption results in sudden evaporation of a thin layer of divertor plate material, which acts as vapor shield and protects the target from further excessive evaporation. Formation and effectiveness of the vapor shield are theoretically modeled and experimentally investigated at the 2MK-200 facility under conditions simulating the thermal quench phase of ITER tokamak plasma disruptions. In the optical wavelength range C II, C III, C IV emission lines for graphite, Cu I, Cu II lines for copper and continuum radiation for tungsten samples are observed in the target plasma. The plasma expands along the magnetic field lines with velocities of (4±1)x10 6 cm/s for graphite and 10 5 cm/s for copper. Modeling was done with a radiation hydrodynamics code in one-dimensional planar geometry. The multifrequency radiation transport is treated in flux limited diffusion and in forward reverse transport approximation. In these first modeling studies the overall shielding efficiency for carbon and tungsten defined as ratio of the incident energy and the vaporization energy for power densities of 10 MW/cm 2 exceeds a factor of 30. The vapor shield is established within 2 μs, the power fraction to the target after 10 μs is below 3% and reaches in the stationary state after about 20 μs a value of around 1.5%. ((orig.))
International Nuclear Information System (INIS)
Davison, C.C.; Kozak, E.T.; Frost, L.H.; Everitt, R.A.; Brown, A.; Gascoyne, M.; Scheier, N.W.
1999-01-01
Plutonic rocks of the Canadian Shield were investigated as a potential host medium for nuclear fuel waste disposal of used CANDU nuclear fuel. Field investigations at several geologic research areas on the Shield have shown that major fracture zones are the dominant pathways for the large scale movement of groundwater and solutes through plutonic rock bodies. Because of this, a significant amount of the geoscience work has focused on methods to identify, characterize and model the radionuclide transport properties of major fracture zones in the fractured plutonic rocks of the Shield. In order to quantify the transport properties of such fracture zones a series of, groundwater tracer tests were performed over a period of several years in several major, low dipping fracture zones. Sixteen tracer tests were performed using dipole recirculation methods to evaluate transport over distance scales ranging from 17 m to 700 m. It was concluded that only tracer tests can provide useful estimates of the effective porosity and dispersivity characteristics of these large fracture zones in plutonic rocks of the Canadian Shield. (author)
Under Water Thermal Cutting of the Moderator Vessel and Thermal Shield
International Nuclear Information System (INIS)
Loeb, A.; Sokcic-Kostic, M.; Eisenmann, B.; Prechtl, E.
2007-01-01
This paper presents the segmentation of the in 8 meter depth of water and for cutting through super alloyed moderator vessel and of the thermal shield of the MZFR stainless steel up to 130 mm wall thickness. Depending on the research reactor by means of under water plasma and contact arc metal cutting. The moderator vessel and the thermal shield are the most essential parts of the MZFR reactor vessel internals. These components have been segmented in 2005 by means of remotely controlled under water cutting utilizing a special manipulator system, a plasma torch and CAMC (Contact Arc Metal Cutting) as cutting tools. The engineered equipment used is a highly advanced design developed in a two years R and D program. It was qualified to cut through steel walls of more than 100 mm thickness in 8 meters water depth. Both the moderator vessel and the thermal shield had to be cut into such size that the segments could afterwards be packed into shielded waste containers each with a volume of roughly 1 m 3 . Segmentation of the moderator vessel and of the thermal shield was performed within 15 months. (author)
Application of a calculational model for thermal neutrons through biological shields
Energy Technology Data Exchange (ETDEWEB)
Hathout, A M [Nuclear engineering safety department, national center for nuclear safety and radiation, Nasr City Cairo, (Egypt)
1995-10-01
In this work a computational program, based on the Boltzmann transport integrodifferential equation, is applied. The scattering kernel is represented by the synthetic scattering model. The behaviour of thermal neutron in hydrogenous materials, which can be used as biological shields, are studied. These materials are water, polyethylene, Oak-Ridge concrete, ordinary concrete and manganese concrete. The data obtained are presented in tables. The results are analysed and compared with similar experimental values. Safety evaluation and environmental impact are discussed. 2 tabs.
Pressure Safety: Advanced Self-Study 30120
Energy Technology Data Exchange (ETDEWEB)
Glass, George [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)
2016-02-29
Pressure Safety Advance Self-Study (Course 30120) consists of an introduction, five modules, and a quiz. To receive credit in UTrain for completing this course, you must score 80% or better on the 15-question quiz (check UTrain). Directions for initiating the quiz are appended to the end of this training manual. This course contains several links to LANL websites. UTrain might not support active links, so please copy links into the address line in your browser.
International Nuclear Information System (INIS)
Valmianski, Emanuil I.; Petzoldt, Ronald W.; Alexander, Neil B.
2003-01-01
The heat flux from both gas convection and chamber radiation on a direct drive target must be limited to avoid target damage from excessive D-T temperature increase. One of the possibilities of protecting the target is a wake shield flying in front of the target. A shield will also reduce drag force on the target, thereby facilitating target tracking and position prediction. A Direct Simulation Monte Carlo (DSMC) code was used to calculate convection heat loads as boundary conditions input into ANSYS thermal calculations. These were used for studying the quality of target protection depending on various shapes of shields, target-shield distance, and protective properties of the shield moving relative to the target. The results show that the shield can reduce the convective heat flux by a factor of 2 to 5 depending on pressure, temperature, and velocity. The protective effect of a shield moving relative to the target is greater than the protective properties of a fixed shield. However, the protective effect of a shield moving under the drag force is not sufficient for bringing the heat load on the target down to the necessary limit. Some other ways of diminishing heat flux using a protective shield are discussed
International Nuclear Information System (INIS)
Burns, T.J.
1994-01-01
An Xwindow application capable of importing geometric information directly from two Computer Aided Design (CAD) based formats for use in radiation transport and shielding analyses is being developed at ORNL. The application permits the user to graphically view the geometric models imported from the two formats for verification and debugging. Previous models, specifically formatted for the radiation transport and shielding codes can also be imported. Required extensions to the existing combinatorial geometry analysis routines are discussed. Examples illustrating the various options and features which will be implemented in the application are presented. The use of the application as a visualization tool for the output of the radiation transport codes is also discussed
International Nuclear Information System (INIS)
Cho, Yong In; Kim, Ja Mee; Kim, Jung Hoon
2017-01-01
To better understand the distribution of deposited energy of beta and gamma rays according to changes in shielding materials and thicknesses when radionuclides are used for therapeutic nuclear medicine, a simulation was conducted. The results showed that due to the physical characteristics of each therapeutic radionuclide, the thicknesses of shielding materials at which beta-ray shielding takes place varied. Additional analysis of the shielding of gamma ray was conducted for radionuclides that emit both beta and gamma rays simultaneously with results showing shielding effects proportional to the atomic number and density of the shielding materials. Also, analysis of bremsstrahlung emission after beta-ray interactions in the simulation revealed that the occurrence of bremsstrahlung was relatively lower than theoretically calculated and varied depending on different radionuclides. (authors)
Mick, D J; Ackerman, M H
2000-01-01
This purpose of this study was to differentiate between the roles of clinical nurse specialists and acute care nurse practitioners. Hypothesized blending of the clinical nurse specialist and acute care nurse practitioner roles is thought to result in an acute care clinician who integrates the clinical skills of the nurse practitioner with the systems knowledge, educational commitment, and leadership ability of the clinical nurse specialist. Ideally, this role blending would facilitate excellence in both direct and indirect patient care. The Strong Model of Advanced Practice, which incorporates practice domains of direct comprehensive care, support of systems, education, research, and publication and professional leadership, was tested to search for practical evidence of role blending. This descriptive, exploratory, pilot study included subjects (N = 18) solicited from an academic medical center and from an Internet advanced practice listserv. Questionnaires included self-ranking of expertise in practice domains, as well as valuing of role-related tasks. Content validity was judged by an expert panel of advanced practice nurses. Analyses of descriptive statistics revealed that clinical nurse specialists, who had more experience both as registered nurses and in the advanced practice nurse role, self-ranked their expertise higher in all practice domains. Acute care nurse practitioners placed higher importance on tasks related to direct comprehensive care, including conducting histories and physicals, diagnosing, and performing diagnostic procedures, whereas clinical nurse specialists assigned greater importance to tasks related to education, research, and leadership. Levels of self-assessed clinical expertise as well as valuing of role-related tasks differed among this sample of clinical nurse specialists and acute care nurse practitioners. Groundwork has been laid for continuing exploration into differentiation in advanced practice nursing roles. As the clinical
The shielding calculation for the CN guide shielding assembly in HANARO
International Nuclear Information System (INIS)
Kim, H. S.; Lee, B. C.; Lee, K. H.; Kim, H.
2006-01-01
The cold neutron research facility in HANARO is under construction. The area including neutron guides and rotary shutter in the reactor hall should be shielded by the guide shielding assembly which is constructed of heavy concrete blocks and structure. The guide shielding assembly is divided into 2 parts, A and B. Part A is about 6.4 meters apart from the reactor biological shield and it is constructed of heavy concrete blocks whose density is above 4.0g/cm 3 . And part B is a fixed heavy concrete structure whose density is above 3.5g/cm 3 . The rotary shutter is also made with heavy concrete whose density is above 4.0g/cm 3 and includes 5 neutron guides inside. It can block the neutron beam by rotating when CNS is not operating. The dose criterion outside the guide shielding assembly is established as 12.5 μSv/hr which is also applied to reactor shielding in HANARO
Shielding synchrotron light sources: Advantages of circular shield walls tunnels
Energy Technology Data Exchange (ETDEWEB)
Kramer, S.L. [Design and Accelerator Operations Consulting, 568 Wintergreen Ct Ridge, NY 11961 (United States); Ghosh, V.J.; Breitfeller, M. [NSLS-II, Brookhaven National Laboratory, Upton, NY 11973 (United States)
2016-08-11
Third generation high brightness light sources are designed to have low emittance and high current beams, which contribute to higher beam loss rates that will be compensated by Top-Off injection. Shielding for these higher loss rates will be critical to protect the projected higher occupancy factors for the users. Top-Off injection requires a full energy injector, which will demand greater consideration of the potential abnormal beam miss-steering and localized losses that could occur. The high energy electron injection beam produce significantly higher neutron component dose to the experimental floor than lower energy injection and ramped operations. High energy neutrons produced in the forward direction from thin target beam losses are a major component of the dose rate outside the shield walls of the tunnel. The convention has been to provide thicker 90° ratchet walls to reduce this dose to the beam line users. We present an alternate circular shield wall design, which naturally and cost effectively increases the path length for this forward radiation in the shield wall and thereby substantially decreasing the dose rate for these beam losses. This shield wall design will greatly reduce the dose rate to the users working near the front end optical components but will challenge the beam line designers to effectively utilize the longer length of beam line penetration in the shield wall. Additional advantages of the circular shield wall tunnel are that it's simpler to construct, allows greater access to the insertion devices and the upstream in tunnel beam line components, as well as reducing the volume of concrete and therefore the cost of the shield wall.
SU-F-I-71: Fetal Protection During Fluoroscopy: To Shield Or Not to Shield?
International Nuclear Information System (INIS)
Joshi, S; Vanderhoek, M
2016-01-01
Purpose: Lead aprons are routinely used to shield the fetus from radiation during fluoroscopically guided interventions (FGI) involving pregnant patients. When placed in the primary beam, lead aprons often reduce image quality and increase fluoroscopic radiation output, which can adversely affect fetal dose. The purpose of this work is to identify an effective and practical method to reduce fetal dose without affecting image quality. Methods: A pregnant patient equivalent abdominal phantom is set on the table along with an image quality test object (CIRS model 903) representing patient anatomy of interest. An ion chamber is positioned at the x-ray beam entrance to the phantom, which is used to estimate the relative fetal dose. For three protective methods, image quality and fetal dose measurements are compared to baseline (no protection):1. Lead apron shielding the entire abdomen; 2. Lead apron shielding part of the abdomen, including the fetus; 3. Narrow collimation such that fetus is excluded from the primary beam. Results: With lead shielding the entire abdomen, the dose is reduced by 80% relative to baseline along with a drastic deterioration of image quality. With lead shielding only the fetus, the dose is reduced by 65% along with complete preservation of image quality, since the image quality test object is not shielded. However, narrow collimation results in 90% dose reduction and a slight improvement of image quality relative to baseline. Conclusion: The use of narrow collimation to protect the fetus during FGI is a simple and highly effective method that simultaneously reduces fetal dose and maintains sufficient image quality. Lead aprons are not as effective at fetal dose reduction, and if placed improperly, they can severely degrade image quality. Future work aims to investigate a wider variety of fluoroscopy systems to confirm these results across many different system geometries.
SU-F-I-71: Fetal Protection During Fluoroscopy: To Shield Or Not to Shield?
Energy Technology Data Exchange (ETDEWEB)
Joshi, S; Vanderhoek, M [Henry Ford Health System, Detroit, MI (United States)
2016-06-15
Purpose: Lead aprons are routinely used to shield the fetus from radiation during fluoroscopically guided interventions (FGI) involving pregnant patients. When placed in the primary beam, lead aprons often reduce image quality and increase fluoroscopic radiation output, which can adversely affect fetal dose. The purpose of this work is to identify an effective and practical method to reduce fetal dose without affecting image quality. Methods: A pregnant patient equivalent abdominal phantom is set on the table along with an image quality test object (CIRS model 903) representing patient anatomy of interest. An ion chamber is positioned at the x-ray beam entrance to the phantom, which is used to estimate the relative fetal dose. For three protective methods, image quality and fetal dose measurements are compared to baseline (no protection):1. Lead apron shielding the entire abdomen; 2. Lead apron shielding part of the abdomen, including the fetus; 3. Narrow collimation such that fetus is excluded from the primary beam. Results: With lead shielding the entire abdomen, the dose is reduced by 80% relative to baseline along with a drastic deterioration of image quality. With lead shielding only the fetus, the dose is reduced by 65% along with complete preservation of image quality, since the image quality test object is not shielded. However, narrow collimation results in 90% dose reduction and a slight improvement of image quality relative to baseline. Conclusion: The use of narrow collimation to protect the fetus during FGI is a simple and highly effective method that simultaneously reduces fetal dose and maintains sufficient image quality. Lead aprons are not as effective at fetal dose reduction, and if placed improperly, they can severely degrade image quality. Future work aims to investigate a wider variety of fluoroscopy systems to confirm these results across many different system geometries.
INTOR radiation shielding for personnel access
International Nuclear Information System (INIS)
Gohar, Y.; Abdou, M.
1981-01-01
The INTOR reactor shield system consists of the blanket, bulk shield, penetration shield, component shield, and biological shield. The bulk shield consists of two parts: (a) the inboard shield; and (b) the outboard shield. The distinction between the different components of the shield system is essential to satisfy the different design constraints and achieve various objectives
Zöller, G; Figel, M; Denk, J; Schulz, K; Sabo, A
2016-03-01
Eye lens radiation exposure during radiologically-guided endoscopic procedures may result in radiation-induced cataracts; therefore, we investigated the ocular radiation exposure during ureteroscopy on a phantom model. Using an Alderson phantom model and eye lens dosimeters, we measured the ocular radiation exposure depending on the number of X-ray images and on the duration of fluoroscopic imaging. The measurements were done with and without using a face protection shield. We could demonstrate that a significant ocular radiation exposure can occur, depending on the number of X-ray images and on the duration time of fluoroscopy. Eye lens doses up to 0.025 mSv were recorded even using modern digital X-ray systems. Using face protection shields this ocular radiation exposure can be reduced to a minimum. The International Commission on Radiological Protection (ICRP) recommendations of a mean eye lens dosage of 20 mSv/year may be exceeded during repeated ureteroscopy by a high volume surgeon. Using a face protection shield, the eye lens dose during ureteroscopy could be reduced to a minimum in a phantom model. Further investigations will show whether these results can be transferred to real life ureteroscopic procedures.
Measurement accuracy in shielded magnetic fields
International Nuclear Information System (INIS)
Bottauscio, Oriano; Chiampi, Mario; Crotti, Gabriella; Zucca, Mauro
2005-01-01
The measurement error due to both the probe size averaging effect and the coil arrangement is investigated when magnetic field measurements are performed in close proximity to different planar shields. The analysis is carried on through a hybrid FEM/BEM model which employs the 'thin shield' technique. Ferromagnetic, pure conductive and multilayer screens are taken into consideration and an estimation of the errors for concentric and non-concentric coil probes is given. The numerical results are validated by experiments
Self-organized critical model for protein folding
Moret, M. A.
2011-09-01
The major factor that drives a protein toward collapse and folding is the hydrophobic effect. At the folding process a hydrophobic core is shielded by the solvent-accessible surface area of the protein. We study the fractal behavior of 5526 protein structures present in the Brookhaven Protein Data Bank. Power laws of protein mass, volume and solvent-accessible surface area are measured independently. The present findings indicate that self-organized criticality is an alternative explanation for the protein folding. Also we note that the protein packing is an independent and constant value because the self-similar behavior of the volumes and protein masses have the same fractal dimension. This power law guarantees that a protein is a complex system. From the analyzed data, q-Gaussian distributions seem to fit well this class of systems.
Shielding features of quarry stone
International Nuclear Information System (INIS)
Hernandez V, C.; Contreras S, H.; Hernandez A, L.; Baltazar R, A.; Escareno J, E.; Mares E, C. A.; Vega C, H. R.
2010-10-01
Quarry stone lineal attenuation coefficient for gamma-rays has been obtained. In Zacatecas, quarry stone is widely utilized as a decorative item in buildings, however its shielding features against gamma-rays unknown. The aim of this work is to determine the shielding properties of quarry stone against γ-rays using Monte Carlo calculations where a detailed model of a good geometry experimental setup was carried out. In the calculations 10 pieces 10 X 10 cm 2 of different thickness were utilized to evaluate the photons transmission as the quarry stone thickness is increased. It was noticed that transmitted photons decay away as the shield thickness is increased, these results were fitted to an exponential function were the linear attenuation coefficient was estimated. Also, using XCOM code the linear attenuation coefficient from several keV up to 100 MeV was estimated. From the comparison between Monte Carlo results and XCOM calculations a good agreement was found. For 0.662 MeV γ-rays the attenuation coefficient of quarry stone, whose density is 2.413 g-cm -3 , is 0.1798 cm -1 , this mean a X 1/2 = 3.9 cm, X 1/4 = 7.7 cm, X 1/10 = 12.8 cm, and X 1/100 = 25.6 cm. Having the information of quarry stone performance as shielding give the chance to use this material to shield X and γ-ray facilities. (Author)
Weber, N; Monnin, P; Elandoy, C; Ding, S
2015-12-01
Given the contribution of scattered radiations to patient dose in CT, apron shielding is often used for radiation protection. In this study the efficiency of apron was assessed with a model-based approach of the contributions of the four scatter sources in CT, i.e. external scattered radiations from the tube and table, internal scatter from the patient and backscatter from the shielding. For this purpose, CTDI phantoms filled with thermoluminescent dosimeters were scanned without apron, and then with an apron at 0, 2.5 and 5 cm from the primary field. Scatter from the tube was measured separately in air. The scatter contributions were separated and mathematically modelled. The protective efficiency of the apron was low, only 1.5% in scatter dose reduction on average. The apron at 0 cm from the beam lowered the dose by 7.5% at the phantom bottom but increased the dose by 2% at the top (backscatter) and did not affect the centre. When the apron was placed at 2.5 or 5 cm, the results were intermediate to the one obtained with the shielding at 0 cm and without shielding. The apron effectiveness is finally limited to the small fraction of external scattered radiation. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
International Nuclear Information System (INIS)
Kobayashi, Torakichi; Sugawara, Takeo.
1983-01-01
Purpose: To reduce the weight and stabilize the configuration of a radiation shielding plate which is used in close contact with an object to be irradiated with radiation rays. Constitution: The radiation shielding plate comprises a substrate made of lead glass and a metallic lead coating on the surface of the substrate by means of plating, vapor deposition or the like. Apertures for permeating radiation rays are formed to the radiation shielding plate. Since the shielding plate is based on a lead glass plate, a sufficient mechanical strength can be obtained with a thinner structure as compared with the conventional plate made of metallic lead. Accordingly, if the shielding plate is disposed on a soft object to be irradiated with radiation rays, the object and the plate itself less deform to obtain a radiation irradiation pattern with distinct edges. (Moriyama, K.)
Shielded battery syndrome: a new hardware complication of deep brain stimulation.
Chelvarajah, Ramesh; Lumsden, Daniel; Kaminska, Margaret; Samuel, Michael; Hulse, Natasha; Selway, Richard P; Lin, Jean-Pierre; Ashkan, Keyoumars
2012-01-01
Deep brain stimulation hardware is constantly advancing. The last few years have seen the introduction of rechargeable cell technology into the implanted pulse generator design, allowing for longer battery life and fewer replacement operations. The Medtronic® system requires an additional pocket adaptor when revising a non-rechargeable battery such as their Kinetra® to their rechargeable Activa® RC. This additional hardware item can, if it migrates superficially, become an impediment to the recharging of the battery and negate the intended technological advance. To report the emergence of the 'shielded battery syndrome', which has not been previously described. We reviewed our deep brain stimulation database to identify cases of recharging difficulties reported by patients with Activa RC implanted pulse generators. Two cases of shielded battery syndrome were identified. The first required surgery to reposition the adaptor to the deep aspect of the subcutaneous pocket. In the second case, it was possible to perform external manual manipulation to restore the adaptor to its original position deep to the battery. We describe strategies to minimise the occurrence of the shielded battery syndrome and advise vigilance in all patients who experience difficulty with recharging after replacement surgery of this type for the implanted pulse generator. Copyright © 2012 S. Karger AG, Basel.
Infinite slab-shield dose calculations
International Nuclear Information System (INIS)
Russell, G.J.
1989-01-01
I calculated neutron and gamma-ray equivalent doses leaking through a variety of infinite (laminate) slab-shields. In the shield computations, I used, as the incident neutron spectrum, the leakage spectrum (<20 MeV) calculated for the LANSCE tungsten production target at 90 degree to the target axis. The shield thickness was fixed at 60 cm. The results of the shield calculations show a minimum in the total leakage equivalent dose if the shield is 40-45 cm of iron followed by 20-15 cm of borated (5% B) polyethylene. High-performance shields can be attained by using multiple laminations. The calculated dose at the shield surface is very dependent on shield material. 4 refs., 4 figs., 1 tab
A Simple Accounting-based Valuation Model for the Debt Tax Shield
Directory of Open Access Journals (Sweden)
Andreas Scholze
2010-05-01
Full Text Available This paper describes a simple way to integrate the debt tax shield into an accounting-based valuation model. The market value of equity is determined by forecasting residual operating income, which is calculated by charging operating income for the operating assets at a required return that accounts for the tax benefit that comes from borrowing to raise cash for the operations. The model assumes that the firm maintains a deterministic financial leverage ratio, which tends to converge quickly to typical steady-state levels over time. From a practical point of view, this characteristic is of particular help, because it allows a continuing value calculation at the end of a short forecast period.
International Nuclear Information System (INIS)
Miller, J.S.
1987-01-01
An electromagnetic shield is described comprising: closed, electrically-conductive rings, each having an open center; and binder means for arranging the rings in a predetermined, fixed relationship relative to each other, the so-arranged rings and binder means defining an outer surface; wherein electromagnetic energy received by the shield from a source adjacent its outer surface induces an electrical current to flow in a predetermined direction adjacent and parallel to the outer surface, through the rings; and wherein each ring is configured to cause source-induced alternating current flowing through the portion of the ring closest to the outer surface to electromagnetically induce an oppositely-directed current in the portion of the ring furthest from the surface, such oppositely-directed current bucking any source-induced current in the latter ring portion and thus reducing the magnitude of current flowing through it, whereby the electromagnetic shielding effected by the shield is enhanced
Conversion Factors for Predicting Unshielded Dose Rates in Shielded Waste
International Nuclear Information System (INIS)
Clapham, M.; Seamans Jr, J.V.; Arbon, R.E.
2009-01-01
This document describes the methodology developed and used by the Advanced Mixed Waste Treatment Project for determining the activity content and the unshielded surface dose rate for lead lined containers contaminated with transuranic waste. Several methods were investigated: - Direct measurement of the dose rate after removing the shielding. - Use of a MicroShield R derived dose conversion factor, (mRem/hr unshielded )/(mRem/hr shielded ), applied to the measured surface dose rate to estimate the unshielded surface dose rate. - Use of a MicroShield R derived activity conversion factor, mRem/hr unshielded /Ci, applied to the measured activity to estimate the unshielded dose rate. - Use of an empirically derived activity conversion factor, mRem/hr unshielded /Ci, applied to the measured activity to estimate the unshielded dose rate. The last approach proved to be the most efficacious by using a combination of nondestructive assay and empirically defined dose rate conversion factors. Empirically derived conversion factors were found to be highly dependent upon the matrix of the waste. Use of conversion factors relied on activity values corrected to address the presence of a lead liner. (authors)
Electromagnetic shielding effectiveness of 3D printed polymer composites
Viskadourakis, Z.; Vasilopoulos, K. C.; Economou, E. N.; Soukoulis, C. M.; Kenanakis, G.
2017-12-01
We report on preliminary results regarding the electromagnetic shielding effectiveness of various 3D printed polymeric composite structures. All studied samples were fabricated using 3D printing technology, following the fused deposition modeling approach, using commercially available filaments as starting materials. The electromagnetic shielding performance of the fabricated 3D samples was investigated in the so called C-band of the electromagnetic spectrum (3.5-7.0 GHz), which is typically used for long-distance radio telecommunications. We provide evidence that 3D printing technology can be effectively utilized to prepare operational shields, making them promising candidates for electromagnetic shielding applications for electronic devices.
Cooling Performance of TBM-shield Designed for Manufacturability
International Nuclear Information System (INIS)
Park, Seong Dae; Lee, Dong Won; Kim, Dong Jun; Yoon, Jae Sung; Ahn, Mu Young
2016-01-01
Helium cooled ceramic reflector (HCCR) test blanket module (TBM) is composed of four sub-modules and a common back manifold (BM). The associated shield is a water-cooled 316L(N)-IG block with internal cooling channels. The purpose of the TBM-shield is to make the condition with the allowable neutron flux and dose rate level. The radially continuous layers of water and structure were configured. The main purpose of the shield is to reduce the neutron flux by absorbing the neutron in the structure. The water could act as the moderator and cool down the structure which is heated due to the reaction with the neutrons. The moderated neutrons are easily absorbed by the structure. It could meet the criteria for the minimum neutron flux by increasing the thickness of structure. The formation of inside cooling channel in the TBM-shield should be considered while maintaining the allowable temperature range. In this work, a manufacturing process including the formation of inside cooling channel was presented. Current design and thermal analysis results for the TBM-shield were presented. The geometry of the shield blocks was considerably changed. The coolant channel was exposed to the outer surface of the TBM-shield. The overall manufacturing process is simplified compared with the previous process of CD model
Cooling Performance of TBM-shield Designed for Manufacturability
Energy Technology Data Exchange (ETDEWEB)
Park, Seong Dae; Lee, Dong Won; Kim, Dong Jun; Yoon, Jae Sung [KAERI, Daejeon (Korea, Republic of); Ahn, Mu Young [NFRI, Daejeon (Korea, Republic of)
2016-05-15
Helium cooled ceramic reflector (HCCR) test blanket module (TBM) is composed of four sub-modules and a common back manifold (BM). The associated shield is a water-cooled 316L(N)-IG block with internal cooling channels. The purpose of the TBM-shield is to make the condition with the allowable neutron flux and dose rate level. The radially continuous layers of water and structure were configured. The main purpose of the shield is to reduce the neutron flux by absorbing the neutron in the structure. The water could act as the moderator and cool down the structure which is heated due to the reaction with the neutrons. The moderated neutrons are easily absorbed by the structure. It could meet the criteria for the minimum neutron flux by increasing the thickness of structure. The formation of inside cooling channel in the TBM-shield should be considered while maintaining the allowable temperature range. In this work, a manufacturing process including the formation of inside cooling channel was presented. Current design and thermal analysis results for the TBM-shield were presented. The geometry of the shield blocks was considerably changed. The coolant channel was exposed to the outer surface of the TBM-shield. The overall manufacturing process is simplified compared with the previous process of CD model.
CERN Library
2013-01-01
MicroShield® is a comprehensive photon/gamma ray shielding and dose assessment programme. It is widely used for designing shields, estimating source strength from radiation measurements, minimising exposure to people, and teaching shielding principles. Integrated tools allow the graphing of results, material and source file creation, source inference with decay (dose-to-Bq calculations accounting for decay and daughter buildup), the projection of exposure rate versus time as a result of decay, access to material and nuclide data, and decay heat calculations. The latest version is able to export results using Microsoft Office (formatted and colour-coded for readability). Sixteen geometries accommodate offset dose points and as many as ten standard shields plus source self-shielding and cylinder cladding are available. The library data (radionuclides, attenuation, build-up and dose conversion) reflect standard data from ICRP 38 and 107* as well as ANSI/ANS standards and RSICC publicat...
Magnet Architectures and Active Radiation Shielding Study - SR2S Workshop
Westover, Shane; Meinke, Rainer; Burger, William; Ilin, Andrew; Nerolich, Shaun; Washburn, Scott
2014-01-01
Analyze new coil configurations with maturing superconductor technology -Develop vehicle-level concept solutions and identify engineering challenges and risks -Shielding performance analysis Recent advances in superconducting magnet technology and manufacturing have opened the door for re-evaluating active shielding solutions as an alternative to mass prohibitive passive shielding.Publications on static magnetic field environments and its bio-effects were reviewed. Short-term exposure information is available suggesting long term exposure may be okay. Further research likely needed. center dotMagnetic field safety requirements exist for controlled work environments. The following effects have been noted with little noted adverse effects -Magnetohydrodynamic (MHD) effects on ionized fluids (e.g. blood) creating an aortic voltage change -MHD interaction elevates blood pressure (BP) center dot5 Tesla equates to 5% BP elevation -Prosthetic devises and pacemakers are an issue (access limit of 5 gauss).
Investigation on Shielding Failure of a Novel 400 kV Composite tower
DEFF Research Database (Denmark)
Wang, Qian; Jahangiri, Tohid; Bak, Claus Leth
2018-01-01
In this paper, the lightning shielding performance of a newly-designed 400 kV double-circuit composite tower is investigated. Based on a revised EGM method, traditional shielding failure regions, located at both sides of a traditional tower is no longer a big issue for the fully composite tower......, due to its unusual ‘Y’ configuration. Instead, a new unprotected region exists in the tower center. The maximum lightning current that can lead to shielding failure and the shielding failure rate (SFR) of the new tower are calculated. To verify results from the revised EGM method, a scale model test...... is conducted. Spatial shielding failure probability around the tower is calculated based on ratio of discharge paths recorded in the test. Moreover, based on test results, the maximum shielding failure lightning currents are obtained. Analysis and results derived from the revised EGM method and scale model...
Advance study of fiber-reinforced self-compacting concrete
International Nuclear Information System (INIS)
Mironova, M.; Ivanova, M.; Naidenov, V.; Georgiev, I.; Stary, J.
2015-01-01
Incorporation in concrete composition of steel macro- and micro – fiber reinforcement with structural function increases the degree of ductility of typically brittle cement-containing composites, which in some cases can replace completely or partially conventional steel reinforcement in the form of rods and meshes. Thus, that can reduce manufacturing, detailing and placement of conventional reinforcement, which enhances productivity and economic efficiency of the building process. In this paper, six fiber-reinforced with different amounts of steel fiber cement-containing self-compacting compositions are investigated. The results of some of their main strength-deformation characteristics are presented. Advance approach for the study of structural and material properties of these type composites is proposed by using the methods of industrial computed tomography. The obtained original tomography results about the microstructure and characteristics of individual structural components make it possible to analyze the effective macro-characteristics of the studied composites. The resulting analytical data are relevant for the purposes of multi-dimensional modeling of these systems. Multifactor structure-mechanical analysis of the obtained with different methods original scientific results is proposed. It is presented a conclusion of the capabilities and effectiveness of complex analysis in the studies to characterize the properties of self-compacting fiber-reinforced concrete
Advance study of fiber-reinforced self-compacting concrete
Mironova, M.; Ivanova, M.; Naidenov, V.; Georgiev, I.; Stary, J.
2015-10-01
Incorporation in concrete composition of steel macro- and micro - fiber reinforcement with structural function increases the degree of ductility of typically brittle cement-containing composites, which in some cases can replace completely or partially conventional steel reinforcement in the form of rods and meshes. Thus, that can reduce manufacturing, detailing and placement of conventional reinforcement, which enhances productivity and economic efficiency of the building process. In this paper, six fiber-reinforced with different amounts of steel fiber cement-containing self-compacting compositions are investigated. The results of some of their main strength-deformation characteristics are presented. Advance approach for the study of structural and material properties of these type composites is proposed by using the methods of industrial computed tomography. The obtained original tomography results about the microstructure and characteristics of individual structural components make it possible to analyze the effective macro-characteristics of the studied composites. The resulting analytical data are relevant for the purposes of multi-dimensional modeling of these systems. Multifactor structure-mechanical analysis of the obtained with different methods original scientific results is proposed. It is presented a conclusion of the capabilities and effectiveness of complex analysis in the studies to characterize the properties of self-compacting fiber-reinforced concrete.
Advance study of fiber-reinforced self-compacting concrete
Energy Technology Data Exchange (ETDEWEB)
Mironova, M., E-mail: mirona@imbm.bas.bg; Ivanova, M., E-mail: magdalena.ivanova@imbm.bas.bg; Naidenov, V., E-mail: valna53@mail.bg [Institute of Mechanics, Bulgarian Academy of Sciences, Acad. G. Bonchev str., bl. 4, Sofia 1113 (Bulgaria); Georgiev, I., E-mail: ivan.georgiev@parallel.bas.bg [Institute of Information and Communication Technologies & Institute of Mathematics and Informatics, Bulgarian Academy of Sciences, Acad. G. Bonchev str., Sofia 1113 (Bulgaria); Stary, J., E-mail: stary@ugn.cas.cz [Institute of Geonics Czech Academy of Sciences, Studentska str., Ostrava 1768 (Czech Republic)
2015-10-28
Incorporation in concrete composition of steel macro- and micro – fiber reinforcement with structural function increases the degree of ductility of typically brittle cement-containing composites, which in some cases can replace completely or partially conventional steel reinforcement in the form of rods and meshes. Thus, that can reduce manufacturing, detailing and placement of conventional reinforcement, which enhances productivity and economic efficiency of the building process. In this paper, six fiber-reinforced with different amounts of steel fiber cement-containing self-compacting compositions are investigated. The results of some of their main strength-deformation characteristics are presented. Advance approach for the study of structural and material properties of these type composites is proposed by using the methods of industrial computed tomography. The obtained original tomography results about the microstructure and characteristics of individual structural components make it possible to analyze the effective macro-characteristics of the studied composites. The resulting analytical data are relevant for the purposes of multi-dimensional modeling of these systems. Multifactor structure-mechanical analysis of the obtained with different methods original scientific results is proposed. It is presented a conclusion of the capabilities and effectiveness of complex analysis in the studies to characterize the properties of self-compacting fiber-reinforced concrete.
International Nuclear Information System (INIS)
Barnett, Marvin; Hack, Joe; Nathan, Steve; White, Travis
2001-01-01
Westinghouse Safety Management Solutions (Westinghouse SMS) has been tasked with providing radiological engineering design support for the new Commercial Light Water Reactor Tritium Extraction Facility (CLWR-TEF) being constructed at the Savannah River Site (SRS). The Remote Handling Building (RHB) of the CLWR-TEF will act as the receiving facility for irradiated targets used in the production of tritium for the U.S. Department of Energy (DOE). Because of the high dose rates, approaching 50 000 rads/h (500 Gy/h) from the irradiated target bundles, significant attention has been made to shielding structures within the facility. One aspect of the design that has undergone intense review is the shield doors. The RHB has six shield doors that needed to be studied with respect to photon streaming. Several aspects had to be examined to ensure that the design meets the radiation dose levels. Both the thickness and streaming issues around the door edges were designed and examined. Photon streaming through and around a shield door is a complicated problem, creating a reliance on computer modeling to perform the analyses. The computer code typically used by the Westinghouse SMS in the evaluation of photon transport through complex geometries is the MCNP Monte Carlo computer code. The complexity of the geometry within the problem can cause problems even with the Monte Carlo codes. Striking a balance between how the code handles transport through the shield door with transport through the streaming paths, particularly with the use of typical variance reduction methods, is difficult when trying to ensure that all important regions of the model are sampled appropriately. The thickness determination used a simple variance reduction technique. In construction, the shield door will not be flush against the wall, so a solid rectangular slab leaves streaming paths around the edges. Administrative controls could be used to control dose to workers; however, 10 CFR 835.1001 states
Simplified shielding calculation system for high-intensity proton accelerators
Energy Technology Data Exchange (ETDEWEB)
Masumura, Tomomi; Nakashima, Hiroshi; Nakane, Yoshihiro; Sasamoto, Nobuo [Center for Neutron Science, Tokai Research Establishment, Japan Atomic Energy Research Institute, Tokai, Ibaraki (Japan)
2000-06-01
A simplified shielding calculation system is developed for applying conceptual shielding design of facilities in the joint project for high-intensity proton accelerators. The system is composed of neutron transmission calculation part for bulk shielding using simplified formulas: Moyer model and Tesch's formula, and neutron skyshine calculation part using an empirical formula: Stapleton's formula. The system is made with the Microsoft Excel software for user's convenience. This report provides a manual for the system as well as calculation conditions used in the calculation such as Moyer model's parameters. In this report preliminary results based on data at December 8, 1999, are also shown as an example. (author)
Wigner, E.P.; Ohlinger, L.E.; Young, G.J.; Weinberg, A.M.
1959-02-17
Radiation shield construction is described for a nuclear reactor. The shield is comprised of a plurality of steel plates arranged in parallel spaced relationship within a peripheral shell. Reactor coolant inlet tubes extend at right angles through the plates and baffles are arranged between the plates at right angles thereto and extend between the tubes to create a series of zigzag channels between the plates for the circulation of coolant fluid through the shield. The shield may be divided into two main sections; an inner section adjacent the reactor container and an outer section spaced therefrom. Coolant through the first section may be circulated at a faster rate than coolant circulated through the outer section since the area closest to the reactor container is at a higher temperature and is more radioactive. The two sections may have separate cooling systems to prevent the coolant in the outer section from mixing with the more contaminated coolant in the inner section.
Causal Agency Theory: Reconceptualizing a Functional Model of Self-Determination
Shogren, Karrie A.; Wehmeyer, Michael L.; Palmer, Susan B.; Forber-Pratt, Anjali J.; Little, Todd J.; Lopez, Shane
2015-01-01
This paper introduces Causal Agency Theory, an extension of the functional model of self-determination. Causal Agency Theory addresses the need for interventions and assessments pertaining to selfdetermination for all students and incorporates the significant advances in understanding of disability and in the field of positive psychology since the…
SHIELD 1.0: development of a shielding calculator program in diagnostic radiology
International Nuclear Information System (INIS)
Santos, Romulo R.; Real, Jessica V.; Luz, Renata M. da; Friedrich, Barbara Q.; Silva, Ana Maria Marques da
2013-01-01
In shielding calculation of radiological facilities, several parameters are required, such as occupancy, use factor, number of patients, source-barrier distance, area type (controlled and uncontrolled), radiation (primary or secondary) and material used in the barrier. The shielding design optimization requires a review of several options about the physical facility design and, mainly, the achievement of the best cost-benefit relationship for the shielding material. To facilitate the development of this kind of design, a program to calculate the shielding in diagnostic radiology was implemented, based on data and limits established by National Council on Radiation Protection and Measurements (NCRP) 147 and SVS-MS 453/98. The program was developed in C⌗ language, and presents a graphical interface for user data input and reporting capabilities. The module initially implemented, called SHIELD 1.0, refers to calculating barriers for conventional X-ray rooms. The program validation was performed by the comparison with the results of examples of shielding calculations presented in NCRP 147.
International Nuclear Information System (INIS)
Soliman, S.E.
1993-01-01
Manufacturing of an emergency movable shield in the hot laboratories center is urgently needed for the safety of personnel in case of accidents or spilling of radioactive materials. In this report, a full design for an emergency shield is presented and the corresponding dose rates behind the shield for different activities (from 1 mCi to 5 Ci) was calculated by using micro shield computer code. 4 figs., 1 tab
Neutron guide shielding for the BIFROST spectrometer at ESS
DEFF Research Database (Denmark)
Mantulnikovs, K.; Bertelsen, M.; Cooper-Jensen, C.P.
2016-01-01
We report on the study of fast-neutron background for the BIFROST spectrometer at ESS. We investigate the effect of background radiation induced by the interaction of fast neutrons from the source with the material of the neutron guide and devise a reasonable fast, thermal/cold neutron shielding...... solution for the current guide geometry using McStas and MCNPX. We investigate the effectiveness of the steel shielding around the guide by running simulations with three different steel thicknesses. The same approach is used to study the efficiencies of the steel wall a flat cylinder pierced by the guide...... in the middle and the polyethylene layer. The final model presented here has a 3 cm thick steel shielding around the guide, 30 cm of polyethylene around the shielding, two 5 mm thick B4C layers and a steel wall at position Z = 38 m, being 1 m thick and 10 m in radius. The final model finally proves...
RadShield: semiautomated shielding design using a floor plan driven graphical user interface.
DeLorenzo, Matthew C; Wu, Dee H; Yang, Kai; Rutel, Isaac B
2016-09-08
The purpose of this study was to introduce and describe the development of RadShield, a Java-based graphical user interface (GUI), which provides a base design that uniquely performs thorough, spatially distributed calculations at many points and reports the maximum air-kerma rate and barrier thickness for each barrier pursuant to NCRP Report 147 methodology. Semiautomated shielding design calculations are validated by two approaches: a geometry-based approach and a manual approach. A series of geometry-based equations were derived giv-ing the maximum air-kerma rate magnitude and location through a first derivative root finding approach. The second approach consisted of comparing RadShield results with those found by manual shielding design by an American Board of Radiology (ABR)-certified medical physicist for two clinical room situations: two adjacent catheterization labs, and a radiographic and fluoroscopic (R&F) exam room. RadShield's efficacy in finding the maximum air-kerma rate was compared against the geometry-based approach and the overall shielding recommendations by RadShield were compared against the medical physicist's shielding results. Percentage errors between the geometry-based approach and RadShield's approach in finding the magnitude and location of the maximum air-kerma rate was within 0.00124% and 14 mm. RadShield's barrier thickness calculations were found to be within 0.156 mm lead (Pb) and 0.150 mm lead (Pb) for the adjacent catheteriza-tion labs and R&F room examples, respectively. However, within the R&F room example, differences in locating the most sensitive calculation point on the floor plan for one of the barriers was not considered in the medical physicist's calculation and was revealed by the RadShield calculations. RadShield is shown to accurately find the maximum values of air-kerma rate and barrier thickness using NCRP Report 147 methodology. Visual inspection alone of the 2D X-ray exam distribution by a medical physicist may not
A Physical Model of Pulsars as Gravitational Shielding and Oscillating Neutron Stars
Directory of Open Access Journals (Sweden)
Zhang T. X.
2015-04-01
Full Text Available Pulsars are thought to be fast rotating neutron stars, synchronously emitting periodic Dirac-delta-shape radio-frequency pulses and Lorentzian-shape oscillating X-rays. The acceleration of charged particles along the magnetic field lines of neutron stars above the magnetic poles that deviate from the rotating axis initiates coherent beams of ra- dio emissions, which are viewed as pulses of radiation whenever the magnetic poles sweep the viewers. However, the conventional lighthouse model of pulsars is only con- ceptual. The mechanism through which particles are accelerated to produce coherent beams is still not fully understood. The process for periodically oscillating X-rays to emit from hot spots at the inner edge of accretion disks remains a mystery. In addition, a lack of reflecting X-rays of the pulsar by the Crab Nebula in the OFF phase does not support the lighthouse model as expected. In this study, we develop a physical model of pulsars to quantitatively interpret the emission characteristics of pulsars, in accor- dance with the author’s well-developed five-dimensional fully covariant Kaluza-Klein gravitational shielding theory and the physics of thermal and accelerating charged par- ticle radiation. The results obtained from this study indicate that, with the significant gravitational shielding by scalar field, a neutron star nonlinearly oscillates and produces synchronous periodically Dirac-delta-shape radio-frequency pulses (emitted by the os- cillating or accelerating charged particles as well as periodically Lorentzian-shape os- cillating X-rays (as the thermal radiation of neutron stars whose temperature varies due to the oscillation. This physical model of pulsars broadens our understanding of neu- tron stars and develops an innovative mechanism to model the emissions of pulsars.
Shielding benchmark problems, (2)
International Nuclear Information System (INIS)
Tanaka, Shun-ichi; Sasamoto, Nobuo; Oka, Yoshiaki; Shin, Kazuo; Tada, Keiko.
1980-02-01
Shielding benchmark problems prepared by Working Group of Assessment of Shielding Experiments in the Research Committee on Shielding Design in the Atomic Energy Society of Japan were compiled by Shielding Laboratory in Japan Atomic Energy Research Institute. Fourteen shielding benchmark problems are presented newly in addition to twenty-one problems proposed already, for evaluating the calculational algorithm and accuracy of computer codes based on discrete ordinates method and Monte Carlo method and for evaluating the nuclear data used in codes. The present benchmark problems are principally for investigating the backscattering and the streaming of neutrons and gamma rays in two- and three-dimensional configurations. (author)
Astronaut Exposures to Ionizing Radiation in a Lightly-Shielded Spacesuit
Wilson, J. W.; Simonsen, L. C.; Shinn, J. L.; Kim, M.-H. Y.; Cucinotta, F. A.; Badavi, F. F.; Atwell, W.
1999-01-01
The normal working and living areas of the astronauts are designed to provide an acceptable level of protection against the hazards of ionizing radiation of the space environment. Still there are occasions when they must don a spacesuit designed mainly for environmental control and mobility and leave the confines of their better-protected domain. This is especially true for deep space exploration. The impact of spacesuit construction on the exposure of critical astronaut organs will be examined in the ionizing radiation environments of free space, the lunar surface and the Martian surface. The computerized anatomical male model is used to evaluate astronaut self-shielding factors and to determine space radiation exposures to critical radiosensitive human organs.
Primary shield displacement and bowing
International Nuclear Information System (INIS)
Scott, K.V.
1978-01-01
The reactor primary shield is constructed of high density concrete and surrounds the reactor core. The inlet, outlet and side primary shields were constructed in-place using 2.54 cm (1 in) thick steel plates as the forms. The plates remained as an integral part of the shields. The elongation of the pressure tubes due to thermal expansion and pressurization is not moving through the inlet nozzle hardware as designed but is accommodated by outward displacement and bowing of the inlet and outlet shields. Excessive distortion of the shields may result in gas seal failures, intolerable helium gas leaks, increased argon-41 emissions, and shield cooling tube failures. The shield surveillance and testing results are presented
Evaluation of the shielding integrity of end-shields in PHWR type NPPs
International Nuclear Information System (INIS)
Sah, B.M.L.; Ramamirtham, B.; Kutty, B.S.
1996-01-01
In the new plants (Narora Atomic Power Plants (NAPP) onwards) relatively higher radiation fields exist on the north and south fuelling machine (FM) vault walls of the E1 100m accessible area passages. These fields were first noticed at NAPS-1 and subsequently at NAPS-2 and KAPS-1. Such surveys done at RAPS have indicated that the fields on these walls would come out to be quite low (only 1-2 mR/h) from sources other than that arising from 41 Ar contamination. RAPS/MAPS experience pointed to adequacy of shielding of the FM vault walls and sufficient overall shielding thickness of the end-shields. Further, radiometry tests of end-shields carried out at Kaiga and RAPP 3 and 4 indicated fairly satisfactory and uniform filling of balls. Hence, incomplete filling of water column of the end-shields due to any venting problem was suspected to be one possible reason for the observed high fields in NAPS and Kakrapar Atomic Power Station (KAPS). Since the presence of high radiation fields, both neutron and gamma, is of long-term concern, a special study/measurement of radiation levels on reactor face during high power operation was undertaken. In order to compare the shielding integrity of the older (RAPS/MAPS solid plate type shielding) and newer (NAPS/KAPS steel ball-filled type) end shields, these experiments were done at MAPS-2 and NAPS-2. (author). 2 refs., 2 tabs
Magnetic shielding for superconducting RF cavities
Masuzawa, M.; Terashima, A.; Tsuchiya, K.; Ueki, R.
2017-03-01
Magnetic shielding is a key technology for superconducting radio frequency (RF) cavities. There are basically two approaches for shielding: (1) surround the cavity of interest with high permeability material and divert magnetic flux around it (passive shielding); and (2) create a magnetic field using coils that cancels the ambient magnetic field in the area of interest (active shielding). The choice of approach depends on the magnitude of the ambient magnetic field, residual magnetic field tolerance, shape of the magnetic shield, usage, cost, etc. However, passive shielding is more commonly used for superconducting RF cavities. The issue with passive shielding is that as the volume to be shielded increases, the size of the shielding material increases, thereby leading to cost increase. A recent trend is to place a magnetic shield in a cryogenic environment inside a cryostat, very close to the cavities, reducing the size and volume of the magnetic shield. In this case, the shielding effectiveness at cryogenic temperatures becomes important. We measured the permeabilities of various shielding materials at both room temperature and cryogenic temperature (4 K) and studied shielding degradation at that cryogenic temperature.
Flux trapping and shielding in irreversible superconductors
International Nuclear Information System (INIS)
Frankel, D.J.
1978-05-01
Flux trappings and shielding experiments were carried out on Pb, Nb, Pb-Bi, Nb-Sn, and Nb-Ti samples of various shapes. Movable Hall probes were used to measure fields near or inside the samples as a function of position and of applied field. The trapping of transverse multipole magnetic fields in tubular samples was accomplished by cooling the samples in an applied field and then smoothly reducing the applied field to zero. Transverse quadrupole and sextupole fields with gradients of over 2000 G/cm were trapped with typical fidelity to the original impressed field of a few percent. Transverse dipole fields of up to 17 kG were also trapped with similar fidelity. Shielding experiments were carried out by cooling the samples in zero field and then gradually applying an external field. Flux trapping and shielding abilities were found to be limited by two factors, the pinning strength of the material, and the susceptibility of a sample to flux jumping. The trapping and shielding behavior of flat disk samples in axial fields and thin-walled tubular samples in transverse fields was modeled. The models, which were based on the concept of the critical state, allowed a connection to be made between the pinning strength and critical current level, and the flux trapping and shielding abilities. Adiabatic and dynamic stability theories are discussed and applied to the materials tested. Good qualitative, but limited quantitative agreement was obtained between the predictions of the theoretical stability criteria and the observed flux jumping behavior
Žukauskaite, A; Plukiene, R; Plukis, A
2007-01-01
Particle accelerators and other high energy facilities produce penetrating ionizing radiation (neutrons and γ-rays) that must be shielded. The objective of this work was to model photon and neutron transport in various materials, usually used as shielding, such as concrete, iron or graphite. Monte Carlo method allows obtaining answers by simulating individual particles and recording some aspects of their average behavior. In this work several nuclear experiments were modeled: AVF 65 – γ-ray beams (1-10 MeV), HIMAC and ISIS-800 – high energy neutrons (20-800 MeV) transport in iron and concrete. The results were then compared with experimental data.
Neutron and gamma-ray spectra measurement on the model of the KS-150 reactor radial shielding
International Nuclear Information System (INIS)
Holman, M.; Hogel, J.; Marik, J.; Kovarik, K.; Franc, L.; Vespalec, R.
1977-01-01
A shortened model of the peripheral region of the KS-150 reactor core consisting of two rows of fuel elements and a reflector was constructed from the peripheral fuel elements of the KS-150 reactor core in an experiment on the TR-0 reactor. The mockup of the thermal shield (10 cm of steel), the pressure vessel (15 cm of steel) and the inner wall of the water biological shielding (2 cm of steel) of the KS-150 reactor were erected outside the TR-0 vessel. Fast neutron and gamma spectra were measured with a stilbene crystal scintillation spectrometer. The resonance neutron spectra were measured with 197 Au, 63 Cu and 23 Na resonance activation detectors. Fast neutron spectra inside the reactor were measured with a 10 mm diameter by 10 mm thick stilbene crystal spectrometer, outside the reactor with a 10 mm diameter by 10 mm thick and a 20 mm diameter by 20 mm thick stilbene crystal spectrometer. Neutron spectra in the energy regions of 1 eV to 3 keV and 0.6 MeV to 0.8 MeV were obtained on the core periphery, on the reflector half-thickness and in front of and behind the reactor thermal shield. Gamma spectra were obtained in front of and behind the thermal shield. It was found that the attenuation of neutron fluxes by the reflector and the thermal shield increased with increasing energy while gamma radiation attenuation decreased with increasing energy. It was not possible to obtain the neutron spectrum in the 10 to 600 keV energy range because suitable detection instrumentation was not available. (J.P.)
Models for transient analyses in advanced test reactors
International Nuclear Information System (INIS)
Gabrielli, Fabrizio
2011-01-01
Several strategies are developed worldwide to respond to the world's increasing demand for electricity. Modern nuclear facilities are under construction or in the planning phase. In parallel, advanced nuclear reactor concepts are being developed to achieve sustainability, minimize waste, and ensure uranium resources. To optimize the performance of components (fuels and structures) of these systems, significant efforts are under way to design new Material Test Reactors facilities in Europe which employ water as a coolant. Safety provisions and the analyses of severe accidents are key points in the determination of sound designs. In this frame, the SIMMER multiphysics code systems is a very attractive tool as it can simulate transients and phenomena within and beyond the design basis in a tightly coupled way. This thesis is primarily focused upon the extension of the SIMMER multigroup cross-sections processing scheme (based on the Bondarenko method) for a proper heterogeneity treatment in the analyses of water-cooled thermal neutron systems. Since the SIMMER code was originally developed for liquid metal-cooled fast reactors analyses, the effect of heterogeneity had been neglected. As a result, the application of the code to water-cooled systems leads to a significant overestimation of the reactivity feedbacks and in turn to non-conservative results. To treat the heterogeneity, the multigroup cross-sections should be computed by properly taking account of the resonance self-shielding effects and the fine intra-cell flux distribution in space group-wise. In this thesis, significant improvements of the SIMMER cross-section processing scheme are described. A new formulation of the background cross-section, based on the Bell and Wigner correlations, is introduced and pre-calculated reduction factors (Effective Mean Chord Lengths) are used to take proper account of the resonance self-shielding effects of non-fuel isotopes. Moreover, pre-calculated parameters are applied
EXPERIMENTAL EVALUATION OF THE THERMAL PERFORMANCE OF A WATER SHIELD FOR A SURFACE POWER REACTOR
International Nuclear Information System (INIS)
Reid, Robert S.; Pearson, J. Bosie; Stewart, Eric T.
2007-01-01
Water based reactor shielding is being investigated for use on initial lunar surface power systems. A water shield may lower overall cost (as compared to development cost for other materials) and simplify operations in the setup and handling. The thermal hydraulic performance of the shield is of significant interest. The mechanism for transferring heat through the shield is natural convection. Natural convection in a 100 kWt lunar surface reactor shield design is evaluated with 2 kW power input to the water in the Water Shield Testbed (WST) at the NASA Marshall Space Flight Center. The experimental data from the WST is used to validate a CFD model. Performance of the water shield on the lunar surface is then predicted with a CFD model anchored to test data. The experiment had a maximum water temperature of 75 C. The CFD model with 1/6-g predicts a maximum water temperature of 88 C with the same heat load and external boundary conditions. This difference in maximum temperature does not greatly affect the structural design of the shield, and demonstrates that it may be possible to use water for a lunar reactor shield.
Experimental Evaluation of the Thermal Performance of a Water Shield for a Surface Power Reactor
International Nuclear Information System (INIS)
Pearson, J. Boise; Stewart, Eric T.; Reid, Robert S.
2007-01-01
Water based reactor shielding is being investigated for use on initial lunar surface power systems. A water shield may lower overall cost (as compared to development cost for other materials) and simplify operations in the setup and handling. The thermal hydraulic performance of the shield is of significant interest. The mechanism for transferring heat through the shield is natural convection. Natural convection in a 100 kWt lunar surface reactor shield design is evaluated with 2 kW power input to the water in the Water Shield Testbed (WST) at the NASA Marshall Space Flight Center. The experimental data from the WST is used to validate a CFD model. Performance of the water shield on the lunar surface is then predicted with a CFD model anchored to test data. The experiment had a maximum water temperature of 75 deg. C. The CFD model with 1/6-g predicts a maximum water temperature of 88 deg. C with the same heat load and external boundary conditions. This difference in maximum temperature does not greatly affect the structural design of the shield, and demonstrates that it may be possible to use water for a lunar reactor shield
EXPERIMENTAL EVALUATION OF THE THERMAL PERFORMANCE OF A WATER SHIELD FOR A SURFACE POWER REACTOR
Energy Technology Data Exchange (ETDEWEB)
REID, ROBERT S. [Los Alamos National Laboratory; PEARSON, J. BOSIE [Los Alamos National Laboratory; STEWART, ERIC T. [Los Alamos National Laboratory
2007-01-16
Water based reactor shielding is being investigated for use on initial lunar surface power systems. A water shield may lower overall cost (as compared to development cost for other materials) and simplify operations in the setup and handling. The thermal hydraulic performance of the shield is of significant interest. The mechanism for transferring heat through the shield is natural convection. Natural convection in a 100 kWt lunar surface reactor shield design is evaluated with 2 kW power input to the water in the Water Shield Testbed (WST) at the NASA Marshall Space Flight Center. The experimental data from the WST is used to validate a CFD model. Performance of the water shield on the lunar surface is then predicted with a CFD model anchored to test data. The experiment had a maximum water temperature of 75 C. The CFD model with 1/6-g predicts a maximum water temperature of 88 C with the same heat load and external boundary conditions. This difference in maximum temperature does not greatly affect the structural design of the shield, and demonstrates that it may be possible to use water for a lunar reactor shield.
International Nuclear Information System (INIS)
Shanmugam, S
2016-01-01
Purpose: In this innovative work we have developed Gynecological Brachytherapy shielding & Non Shielding Applicators and compared with the commercially available applicators by using the indigenously developed 3D Printing machine. Methods: We have successfully indigenously developed the 3D printing machine. Which contain the 3 dimensional motion platform, Heater unit, base plate, ect… To fabricate the Gynecological Brachytherapy shielding & non shielding applicators the 3D design were developed in the computer as virtual design. This virtual design is made in a CAD computer file using a 3D modeling program. Separate programme for the shielding & non shielding applicators. We have also provided the extra catheter insert provision in the applicator for the multiple catheter. The DICOM file of the applicator were then converted to stereo Lithography file for the 3D printer. The shielding & Non Shielding Applicators were printed on a indigenously developed 3D printer material. The same dimensions were used to develop the applicators in the acrylic material also for the comparative study. A CT scan was performed to establish an infill-density calibration curve as well as characterize the quality of the print such as uniformity and the infill pattern. To commission the process, basic CT and dose properties of the printing materials were measured in photon beams and compared against water and soft tissue. Applicator were then scanned to confirm the placement of multiple catheter position. Finally dose distributions with rescanned CTs were compared with those computer-generated applicators. Results: The doses measured from the ion Chamber and X-Omat film test were within 2%. The shielded applicator reduce the rectal dose comparatively with the non shielded applicator. Conclusion: As of submission 3 unique cylinders have been designed, printed, and tested dosimetrically. A standardizable workflow for commissioning custom 3D printed applicators was codified and will be
Energy Technology Data Exchange (ETDEWEB)
Shanmugam, S
2016-06-15
Purpose: In this innovative work we have developed Gynecological Brachytherapy shielding & Non Shielding Applicators and compared with the commercially available applicators by using the indigenously developed 3D Printing machine. Methods: We have successfully indigenously developed the 3D printing machine. Which contain the 3 dimensional motion platform, Heater unit, base plate, ect… To fabricate the Gynecological Brachytherapy shielding & non shielding applicators the 3D design were developed in the computer as virtual design. This virtual design is made in a CAD computer file using a 3D modeling program. Separate programme for the shielding & non shielding applicators. We have also provided the extra catheter insert provision in the applicator for the multiple catheter. The DICOM file of the applicator were then converted to stereo Lithography file for the 3D printer. The shielding & Non Shielding Applicators were printed on a indigenously developed 3D printer material. The same dimensions were used to develop the applicators in the acrylic material also for the comparative study. A CT scan was performed to establish an infill-density calibration curve as well as characterize the quality of the print such as uniformity and the infill pattern. To commission the process, basic CT and dose properties of the printing materials were measured in photon beams and compared against water and soft tissue. Applicator were then scanned to confirm the placement of multiple catheter position. Finally dose distributions with rescanned CTs were compared with those computer-generated applicators. Results: The doses measured from the ion Chamber and X-Omat film test were within 2%. The shielded applicator reduce the rectal dose comparatively with the non shielded applicator. Conclusion: As of submission 3 unique cylinders have been designed, printed, and tested dosimetrically. A standardizable workflow for commissioning custom 3D printed applicators was codified and will be
The construction of radiation shielding for baby ebm
International Nuclear Information System (INIS)
Mohd Rizal Md Chulan; Leo Kwee Wah; Lee Chee Huei; Muhamad Zahidee Taat; Fadzlie Nordin; Abu Bakar Mhd Ghazali; Mohd Yusof Ali; Mohd Rizal Mamat Ibrahim; Syed Nasaruddin Syed Idris; Mahmud Hamid; Mohd Khairi Mohd Said
2005-01-01
The construction of radiation shielding for electron beam machine, Baby EBM is necessary for prevention from x-ray (Bremstrahlung) that produced when electron bombarded the target material. The strength of produced x-ray is depending on electron energy and the atomic number of target material. In the construction process of radiation shielding, a few aspects need to be considered such as shielding material and its thickness to be used, mainframe for radiation shielding and the way fabrication to be done. In this project, the thickness of radiation shielding is calculated manually following the NCRP 51 guidelines whereas for frame design, shielding walls and fabrication is considered that the accelerator devices (accelerating tube, focusing device and neck) is vertically and the whole weight of Baby EBM. From the calculations, the thickness and the material for radiation shielding is to be used are 6mm lead. This radiation shielding has been tested (using the parameters that have been considered) to know the leak of radiation (at all surfaces) and direct radiation below 5 cm from the window. The value of high voltage that applied at accelerating tube is 80 kV and the voltage, current supply at electron gun is 3.0 V, 7.1 A respectively. The result of the testing found that dose rate under the window foil is more than 2000 mSv/hr and at all shielding surfaces are less than 0.5 mSv/hr, which is background reading and this is acceptable as compared to the theoretical calculation. The measurement was done using a survey meter typed Ludlum-model 3. (Author)
Electron correlation effects on geometries and 19F shieldings of fluorobenzenes
International Nuclear Information System (INIS)
Webb, G.A.; Karadakov, P.B.; England, J.A.
2000-01-01
In order to include the effects of electron correlation in ab initio molecular orbital calculations it is necessary to go beyond the single determinant Hartree-Fock (HF) level of theory. In the present investigation the influences of both dynamic and non-dynamic correlation effects on the optimised geometries and 19 F nuclear shielding calculations of the twelve fluorobenzenes are reported.The non-dynamic electron correlation effects are represented by complete-active space self-consistent field (CASSCF) calculations. Second- and fourth-order Moller-Plesset (MP2 and MP4) calculations are used to describe the dynamic electron correlation effects. Some density-functional (DFT) results are also reported which do not distinguish between dynamic and non-dynamic electron correlation. Following the correlated geometry optimisations 19 F nuclear shielding calculations were performed using the gauge-included atomic orbitals (GIAO) procedure, these were undertaken with wave functions which include various levels of electron correlation including HF, CASSCF and MP2. For the calculations of the optimised geometries, and some of the nuclear shieldings the 6-13G** basis set s used whereas the locally-dense [6-13G** on C and H and 6-311++G(2d,2p) on F] set is used for some of the shielding calculations. A comparison of the results of HF shielding calculations using other basis sets is included. Comparison of the calculated geometry and shielding results with relevant, reported, experimental data is made. (author)
Shielding container for radioactive isotopes
International Nuclear Information System (INIS)
Sumi, Tetsuo; Tosa, Masayoshi; Hatogai, Tatsuaki.
1975-01-01
Object: To effect opening and closing bidirectional radiation used particularly for a gamma densimeter or the like by one operation. Structure: This device comprises a rotatable shielding body for receiving radioactive isotope in the central portion thereof and having at least two radiation openings through which radiation is taken out of the isotope, and a shielding container having openings corresponding to the first mentioned radiation openings, respectively. The radioactive isotope is secured to a rotational shaft of the shielding body, and the shielding body is rotated to register the openings of the shielding container with the openings of the shielding body or to shield the openings, thereby effecting radiation and cut off of gamma ray in the bidirection by one operation. (Kamimura, M.)
Quinn, Philip R.; Schwadron, Nathan A.; Townsend, Larry W.; Wimmer-Schweingruber, Robert F.; Case, Anthony W.; Spence, Harlan E.; Wilson, Jody K.; Joyce, Colin J.
2017-08-01
Radiation in the form of solar energetic particles (SEPs) presents a severe risk to the short-term health of astronauts and the success of human exploration missions beyond Earth's protective shielding. Modeling how shielding mitigates the dose accumulated by astronauts is an essential step toward reducing these risks. PREDICCS (Predictions of radiation from REleASE, EMMREM, and Data Incorporating the CRaTER, COSTEP, and other SEP measurements) is an online tool for the near real-time prediction of radiation exposure at Earth, the Moon, and Mars behind various levels of shielding. We compare shielded dose rates from PREDICCS with dose rates from the Cosmic Ray Telescope for the Effects of Radiation (CRaTER) onboard the Lunar Reconnaissance Orbiter (LRO) at the Moon and from the Radiation Assessment Detector (RAD) on the Mars Science Laboratory (MSL) during its cruise phase to Mars for five solar events in 2012 when Earth, MSL, and Mars were magnetically well connected. Calculations of the accumulated dose demonstrate a reasonable agreement between PREDICCS and RAD ranging from as little as 2% difference to 54%. We determine mathematical relationships between shielding levels and accumulated dose. Lastly, the gradient of accumulated dose between Earth and Mars shows that for the largest of the five solar events, lunar missions require aluminum shielding between 1.0 g cm-2 and 5.0 g cm-2 to prevent radiation exposure from exceeding the 30-day limits for lens and skin. The limits were not exceeded near Mars.
Guidelines for beamline and front-end radiation shielding design at the Advanced Photon Source
International Nuclear Information System (INIS)
Fernandez, P.; X-Ray Science Division
2008-01-01
Shielding for the APS will be such that the individual radiation worker dose will be as low as reasonably achievable (ALARA). The ALARA goals for the APS are to keep the total of the work-related radiation exposure (exposure coming from other than natural or medical sources) as far below 500 person-mrem per year, collective total effective dose equivalent, as reasonably achievable. For an individual APS radiation worker, the goal is to keep the maximum occupational total effective dose equivalent of any one employee as far below 200 mrem/yr as reasonably achievable. The ALARA goal for APS beamline scientists is to keep the total of the work-related radiation exposure (exposure coming from other than natural or medical sources) as far below 100 person-mrem per year, collective total effective dose equivalent, as reasonably achievable. For an individual APS beamline scientist, the goal is to keep the maximum occupational total effective dose equivalent of any one scientist as far below 50 mrem/yr as reasonably achievable. The dose is actively monitored by the radiation monitors on the storage ring wall in each sector and by the frequent area surveys performed by the health physics personnel. For cases in which surveys indicate elevated hourly dose rates that may impact worker exposure, additional local shielding is provided to reduce the radiation field to an acceptable level. Passive area monitors are used throughout the facility to integrate doses in various areas. The results are analyzed for trends of increased doses, and shielding in these areas is evaluated and improved, as appropriate. The APS policy for on-site nonradiation workers in the vicinity of the APS facilities requires that the average nonradiation worker dose be below 0.2 mSv/yr (20 mrem/yr). In addition, the dose at the site boundary from all pathways is required to be below 0.1 mSv/yr (10 mrem/yr). For future modifications of the facility, the doses shall be evaluated and additional shielding
Shielding in experimental areas
International Nuclear Information System (INIS)
Stevens, A.; Tarnopolsky, G.; Thorndike, A.; White, S.
1979-01-01
The amount of shielding necessary to protect experimental detectors from various sources of background radiation is discussed. As illustrated an experiment has line of sight to sources extending approx. 90 m upstream from the intersection point. Packing a significant fraction of this space with shielding blocks would in general be unacceptable because primary access to the ring tunnel is from the experimental halls. (1) From basic machine design considerations and the inherent necessity to protect superconducting magnets it is expected that experimental areas in general will be cleaner than at any existing accelerator. (2) Even so, it will likely be necessary to have some shielding blocks available to protect experimental apparatus, and it may well be necessary to have a large amount of shielding available in the WAH. (3) Scraping will likely have some influence on all halls, and retractable apparatus may sometimes be necessary. (4) If access to any tunnel is needed to replace a magnet, one has 96 h (4 days) available to move shielding away to permit access without additional downtime. This (the amount of shielding one can shuffle about in 96 h) is a reasonable upper limit to shielding necessary in a hall
Calculation of a concrete shielding for an ILU-8 D electron accelerator
International Nuclear Information System (INIS)
Helal, A.; Imam, A.
1996-01-01
A concrete shielding for an electron accelerator of 1 MeV is suggested to replace its structural steel shielding. The thickness of such a shield is calculated. The calculational model used is based on standard and transmission curves given in the literature. The calculated concrete shielding is generally adequate to attenuate the accelerator produced radiation to a level 1 μ Gy/h or less at any point outside of the vault enclosure. 5 figs
Calculation of a concrete shielding for an ILU-8 D electron accelerator
Energy Technology Data Exchange (ETDEWEB)
Helal, A [Nuclear Research Center, AEA, Cairo (Egypt); Imam, A [National Center for Nuclear Safety and Radiation Control, AEA, Cairo (Egypt)
1997-12-31
A concrete shielding for an electron accelerator of 1 MeV is suggested to replace its structural steel shielding. The thickness of such a shield is calculated. The calculational model used is based on standard and transmission curves given in the literature. The calculated concrete shielding is generally adequate to attenuate the accelerator produced radiation to a level 1 {mu} Gy/h or less at any point outside of the vault enclosure. 5 figs.
Analysis of the JASPER Program Radial Shield Attenuation Experiment
Energy Technology Data Exchange (ETDEWEB)
Slater, C.O.
1993-01-01
The results of the analysis of the JASPER Program Radial Shield Attenuation Experiment are presented. The experiment was performed in 1986 at the ORNL Tower Shielding Facility. It is the first of six experiments in this cooperative Japanese and American program in support of shielding designs for advanced sodium-cooled reactors. Six different shielding configurations and subconfigurations thereof were studied. The configurations were calculated with the DOT-IV two-dimensional discrete ordinates radiation transport computer code using the R-Z geometry option, a symmetric S{sub 12} quadrature (96 directions), and cross sections from ENDF/B versions IV and V in either a 51- or 61-group structure. Auxiliary codes were used to compute detector responses and prepare cross sections and source input for the DOT-IV calculations. Calculated detector responses were compared with measured responses and the agreement was good to excellent in many cases. However, the agreement for configurations having thick steel or B{sub 4}C regions or for some very large configurations was fair to poor. The disagreement was attributed to cross-section data, broad-group structure, or high background in the measurements. In particular, it is shown that two cross-section sets for ``B give very different results for neutron transmission through the thick B{sub 4}C regions used in one set of experimental configurations. Implications for design calculations are given.
Calculated shielding factors for selected European houses
International Nuclear Information System (INIS)
Hedemann Jensen, P.
1984-12-01
Shielding factors for gamma radiation from activity deposited on structures and ground surfaces have been calculated with the computer model DEPSHIELD for single-family and multi-storey buildings in France, United Kingdom and Denmark. For all three countries it was found that the shielding factors for single-family houses are approximately a factor of 2 - 10 higher that those for buildings with five or more storeys. Away from doors and windows the shielding factors for French, British, and Danish single-family houses are in the range 0.03 - 0.1, 0.06 - 0.4, and 0.07 - 0.3, respectively. The uncertainties of the calculations are discussed and DEPSHIELD-results are compared with other methods as well as with experimental results. (author)
Symbolic math for computation of radiation shielding
International Nuclear Information System (INIS)
Suman, Vitisha; Datta, D.; Sarkar, P.K.; Kushwaha, H.S.
2010-01-01
Radiation transport calculations for shielding studies in the field of accelerator technology often involve intensive numerical computations. Traditionally, radiation transport equation is solved using finite difference scheme or advanced finite element method with respect to specific initial and boundary conditions suitable for the geometry of the problem. All these computations need CPU intensive computer codes for accurate calculation of scalar and angular fluxes. Computation using symbols of the analytical expression representing the transport equation as objects is an enhanced numerical technique in which the computation is completely algorithm and data oriented. Algorithm on the basis of symbolic math architecture is developed using Symbolic math toolbox of MATLAB software. Present paper describes the symbolic math algorithm and its application as a case study in which shielding calculation of rectangular slab geometry is studied for a line source of specific activity. Study of application of symbolic math in this domain evolves a new paradigm compared to the existing computer code such as DORT. (author)
Task force's viewpoint of the current BRH Program. Gonad shield, Part F
International Nuclear Information System (INIS)
Dolezal, A.
1975-01-01
A previous report on radiation protection during diagnostic exposure is reviewed. Some topics discussed are: Task Force regulations for the model by which routine use of patient shielding or gonad shielding would be required; shielding in relation to collimation, scatter radiation, and enforcement of regulations; and proposed regulations for reduction of unnecessary radiation
Neutron shielding and activation of the MASTU device and surrounds
Energy Technology Data Exchange (ETDEWEB)
Taylor, David, E-mail: david.taylor@ccfe.ac.uk [EURATOM/CCFE Fusion Association, Culham Science Centre, Abingdon OX14 3DB (United Kingdom); Lilley, Steven; Turner, Andrew [EURATOM/CCFE Fusion Association, Culham Science Centre, Abingdon OX14 3DB (United Kingdom); Davis, Andrew [Now at College of Engineering, University of Wisconsin, Madison, WI 53706 (United States)
2014-10-15
Highlights: We model neutron shielding for the planned MASTU device; nadequacies in the existing shielding design are remedied; Levels of public exposure are considered; We model activated gamma emission for the device under a worst case scenario. Abstract: A significant functional upgrade is planned for the Mega Ampere Spherical Tokamak (MAST) device, located at Culham in the UK, including the implementation of a notably greater neutral beam injection power. This upgrade will cause the emission of a substantially increased intensity of neutron radiation for a substantially increased amount of time upon operation of the device. Existing shielding and activation precautions are shown to prove insufficient in some regards, and recommendations for improvements are made, including the following areas: shielding doors to MAST shielded facility enclosure (known as “the blockhouse”); north access tunnel; blockhouse roof; west cabling duct. In addition, some specific neutronic dose rate questions are addressed and answered; those discussed here relate to shielding penetrations and dose rate reflected from the air above the device (“skyshine”). It is shown that the alterations to shielding and area access reduce the dose rate in unrestricted areas from greater than 100 μSv/h to less than 2 μSv/h averaged over the working day. The tools used for this analysis are the MCNP (Monte Carlo N-particle) code, used to calculate the three-dimensional spatial distribution of neutron and photon dose rates in and around the device and its shields, and the nuclear inventory code FISPACT, run under the umbrella code MCR2S, used to calculate the time-dependent shutdown dose rate in the region of the device at several decay times.
solvent effect on 14n nmr shielding of glycine, serine, leucine
African Journals Online (AJOL)
a
constants favor the more polar tautomers. Ab initio calculation of nuclear magnetic shielding has become an indispensable aid in the investigation of molecular structure and accurate assignment of NMR spectra of compounds. The solvation effect is taken into account via the self-consistent reaction field (SCRF) method.
Concrete shielding for nuclear ship 'Mutsu'
International Nuclear Information System (INIS)
Nagase, Tetsuo; Saito, Tetsuo
1983-01-01
The repair works of the shielding for the nuclear ship ''Mutsu'' were completed in August, 1982. For the primary shielding, serpentine concrete was adopted as it contains a large quantity of water required for neutron shielding, and in the secondary shielding at the upper part of the reactor containment vessel, the original shielding was abolished, and the heavy concrete (high water content, high density concrete) which is effective for neutron and gamma-ray shielding was newly adopted. In this report, the design and construction using these shielding concrete are outlined. In September, 1974, Mutsu caused radiation leak during the test, and the cause was found to be the fast neutrons streaming through a gap between the reactor pressure vessel and the primary shielding. The repair works were carried out in the Sasebo Shipyard. The outline of the repair works of the shielding is described. The design condition for the shielding, the design standard for the radiation dose outside and inside the ship, the method of shielding analysis and the performance required for shielding concrete are reported. The selection of materials, the method of construction and mixing ratio, the evaluation of the soundness and properties of concrete, and the works of placing the shielding concrete are outlined. (Kako, I.)
Reconciling the self and morality: an empirical model of moral centrality development.
Frimer, Jeremy A; Walker, Lawrence J
2009-11-01
Self-interest and moral sensibilities generally compete with one another, but for moral exemplars, this tension appears to not be in play. This study advances the reconciliation model, which explains this anomaly within a developmental framework by positing that the relationship between the self's interests and moral concerns ideally transforms from one of mutual competition to one of synergy. The degree to which morality is central to an individual's identity-or moral centrality-was operationalized in terms of values advanced implicitly in self-understanding narratives; a measure was developed and then validated. Participants were 97 university students who responded to a self-understanding interview and to several measures of morally relevant behaviors. Results indicated that communal values (centered on concerns for others) positively predicted and agentic (self-interested) values negatively predicted moral behavior. At the same time, the tendency to coordinate both agentic and communal values within narrative thought segments positively predicted moral behavior, indicating that the 2 motives can be adaptively reconciled. Moral centrality holds considerable promise in explaining moral motivation and its development.
Electromagnetic analysis of transient disruption forces on the ITER shield modules
International Nuclear Information System (INIS)
Kotulski, J.D.; Coats, R.S.; Pasik, M.F.
2007-01-01
There are potential abnormal operating environments where the disruption of the plasma currents inside a tokamak induce eddy currents in the shield modules. These currents interact with the large magnetic fields to produce forces in the modules which could potentially cause mechanical failure in the modules and vacuum vessel. For this reason the design and qualification of the ITER shield modules requires appropriate high-fidelity electromagnetic simulations that capture the physics of these situations. These simulations need to include an accurate representation of the disruption currents as well as an accurate electromagnetic model of the shield modules. The purpose of this presentation is to describe the electromagnetic analysis that has been completed using the OPERA-3D product to characterize the forces on the shield modules allocated to the US. We first describe the electromagnetic model of the system which consists of the disruption currents and the shield modules attached to the vacuum vessel. The disruption currents are represented in OPERA-3D using superposition of a large number of solenoids with independent time variation to account for the spatial and temporal variation of the plasma current and position. In addition, the simplified electromagnetic model of the shield modules will be described and discussed. Once the modeling has been described the simulation results are presented. The force computation are also presented and the results discussed. These forces are then used by a mechanical analysis program to compute stresses and torques on a module during the disruption of the plasma currents. (orig.)
Ice shielding in the large scale GENIUS experiment for double beta decay and dark matter search
International Nuclear Information System (INIS)
Klapdor-Kleingrothaus, H.V.; Zdesenko, Yu.G.
1998-01-01
We suggest here the use of ice as shielding material in the large scale GENIUS experiment for the ultimate sensitive double beta decay and dark matter search. The idea is to pack a working volume of several tons of liquid nitrogen, which contains the ''naked'' Ge detectors, inside an ice shielding. Very thin plastic foil would be used in order to prevent leakage of the liquid nitrogen. Due to the excellent advantages of ice shielding (high purity and low cost, self-supporting ability, thermo-isolation and optical properties, safety) this could be another possible way of realization of the GENIUS project. (orig.)
Practical aspects of shielding high-energy particle accelerators
International Nuclear Information System (INIS)
Thomas, R.H.; Univ. of California, Berkeley, CA
1993-09-01
The experimental basis of shielding design for high-energy accelerators that has been established over the past thirty years is described. Particular emphasis is given to the design of large accelerators constructed underground. The first data obtained from cosmic-ray physics were supplemented by basic nuclear physics. When these data proved insufficient, experiments were carried out and interpreted by several empirical formulae -- the most successful of which has been the Moyer Model. This empirical model has been used successfully to design the shields of most synchrotrons currently in operation, and is still being used in preliminary design and to check the results of neutron transport calculations. Accurate shield designs are needed to reduce external radiation levels during accelerator operations and to minimize environmental impacts such as open-quotes skyshineclose quotes and the production of radioactivity in groundwater. Examples of the cost of minimizing such environmental impacts are given
Improved Nuclear Reactor and Shield Mass Model for Space Applications
Robb, Kevin
2004-01-01
New technologies are being developed to explore the distant reaches of the solar system. Beyond Mars, solar energy is inadequate to power advanced scientific instruments. One technology that can meet the energy requirements is the space nuclear reactor. The nuclear reactor is used as a heat source for which a heat-to-electricity conversion system is needed. Examples of such conversion systems are the Brayton, Rankine, and Stirling cycles. Since launch cost is proportional to the amount of mass to lift, mass is always a concern in designing spacecraft. Estimations of system masses are an important part in determining the feasibility of a design. I worked under Michael Barrett in the Thermal Energy Conversion Branch of the Power & Electric Propulsion Division. An in-house Closed Cycle Engine Program (CCEP) is used for the design and performance analysis of closed-Brayton-cycle energy conversion systems for space applications. This program also calculates the system mass including the heat source. CCEP uses the subroutine RSMASS, which has been updated to RSMASS-D, to estimate the mass of the reactor. RSMASS was developed in 1986 at Sandia National Laboratories to quickly estimate the mass of multi-megawatt nuclear reactors for space applications. In response to an emphasis for lower power reactors, RSMASS-D was developed in 1997 and is based off of the SP-100 liquid metal cooled reactor. The subroutine calculates the mass of reactor components such as the safety systems, instrumentation and control, radiation shield, structure, reflector, and core. The major improvements in RSMASS-D are that it uses higher fidelity calculations, is easier to use, and automatically optimizes the systems mass. RSMASS-D is accurate within 15% of actual data while RSMASS is only accurate within 50%. My goal this summer was to learn FORTRAN 77 programming language and update the CCEP program with the RSMASS-D model.
International Nuclear Information System (INIS)
Darling, K.A.M.
1981-01-01
A shielding container incorporates a dense shield, for example of depleted uranium, cast around a tubular member of curvilinear configuration for accommodating a radiation source capsule. A lining for the tubular member, in the form of a close-coiled flexible guide, provides easy replaceability to counter wear while the container is in service. Container life is extended, and maintenance costs are reduced. (author)
Liu, Alan S.; Wang, Hailong; Copeland, Craig R.; Chen, Christopher S.; Shenoy, Vivek B.; Reich, Daniel H.
2016-01-01
The biomechanical behavior of tissues under mechanical stimulation is critically important to physiological function. We report a combined experimental and modeling study of bioengineered 3D smooth muscle microtissues that reveals a previously unappreciated interaction between active cell mechanics and the viscoplastic properties of the extracellular matrix. The microtissues’ response to stretch/unstretch actuations, as probed by microcantilever force sensors, was dominated by cellular actomyosin dynamics. However, cell lysis revealed a viscoplastic response of the underlying model collagen/fibrin matrix. A model coupling Hill-type actomyosin dynamics with a plastic perfectly viscoplastic description of the matrix quantitatively accounts for the microtissue dynamics, including notably the cells’ shielding of the matrix plasticity. Stretch measurements of single cells confirmed the active cell dynamics, and were well described by a single-cell version of our model. These results reveal the need for new focus on matrix plasticity and its interactions with active cell mechanics in describing tissue dynamics. PMID:27671239
Directory of Open Access Journals (Sweden)
Quinn Philip R.
2017-01-01
Full Text Available Radiation in the form of solar energetic particles (SEPs presents a severe risk to the short-term health of astronauts and the success of human exploration missions beyond Earth’s protective shielding. Modeling how shielding mitigates the dose accumulated by astronauts is an essential step toward reducing these risks. PREDICCS (Predictions of radiation from REleASE, EMMREM, and Data Incorporating the CRaTER, COSTEP, and other SEP measurements is an online tool for the near real-time prediction of radiation exposure at Earth, the Moon, and Mars behind various levels of shielding. We compare shielded dose rates from PREDICCS with dose rates from the Cosmic Ray Telescope for the Effects of Radiation (CRaTER onboard the Lunar Reconnaissance Orbiter (LRO at the Moon and from the Radiation Assessment Detector (RAD on the Mars Science Laboratory (MSL during its cruise phase to Mars for five solar events in 2012 when Earth, MSL, and Mars were magnetically well connected. Calculations of the accumulated dose demonstrate a reasonable agreement between PREDICCS and RAD ranging from as little as 2% difference to 54%. We determine mathematical relationships between shielding levels and accumulated dose. Lastly, the gradient of accumulated dose between Earth and Mars shows that for the largest of the five solar events, lunar missions require aluminum shielding between 1.0 g cm−2 and 5.0 g cm−2 to prevent radiation exposure from exceeding the 30-day limits for lens and skin. The limits were not exceeded near Mars.
International Nuclear Information System (INIS)
Kaplan, M.F.
1989-01-01
The increased use of nuclear energy has given rise to a growth in the amount of artificially produced radiation and radioactive materials. The design and construction of shielding to protect people, equipment and structures from the effects of radiation has never been more important. Experience has shown that concrete is an effective, versatile and economical material for the construction of radiation shielding. This book provides information on the principles governing the interaction of radiation with matter and on relevant nuclear physics to give the engineer an understanding of the design and construction of concrete shielding. It covers the physical, mechanical and nuclear properties of concrete; the effects of elevated temperatures and possible damage to concrete due to radiation; basic procedures for the design of concrete radiation shields and finally the special problems associated with their construction and cost. Although written primarily for engineers concerned with the design and construction of concrete shielding, the book also reviews the widely scattered data and information available on this subject and should therefore be of interest to students and those wishing to research further in this field. (author)
Optimization of Savonius turbines using an obstacle shielding the returning blade
Energy Technology Data Exchange (ETDEWEB)
Mohamed, M.H.; Janiga, G.; Pap, E.; Thevenin, D. [Lab. of Fluid Dynamics and Technical Flows, University of Magdeburg ' ' Otto von Guericke' ' (Germany)
2010-11-15
Due to the worldwide energy crisis, research and development activities in the field of renewable energy have been considerably increased in many countries. In Germany, wind energy is becoming particularly important. Although considerable progress has already been achieved, the available technical design is not yet adequate to develop reliable wind energy converters for conditions corresponding to low wind speeds and urban areas. The Savonius turbine appears to be particularly promising for such conditions, but suffers from a poor efficiency. The present study considers a considerably improved design in order to increase the output power of a Savonius turbine with either two or three blades. In addition, the improved design leads to a better self-starting capability. To achieve these objectives, the position of an obstacle shielding the returning blade of the Savonius turbine and possibly leading to a better flow orientation toward the advancing blade is optimized. This automatic optimization is carried out by coupling an in-house optimization library (OPAL) with an industrial flow simulation code (ANSYS-Fluent). The optimization process takes into account the output power coefficient as target function, considers the position and the angle of the shield as optimization parameters, and relies on Evolutionary Algorithms. A considerable improvement of the performance of Savonius turbines can be obtained in this manner, in particular a relative increase of the power output coefficient by more than 27%. It is furthermore demonstrated that the optimized configuration involving a two-blade rotor is better than the three-blade design. (author)
Developments in shielding and criticality assessment for cask design
International Nuclear Information System (INIS)
Watmough, M.H.; Cooper, A.J.; Croxford, R.W.
1993-01-01
This paper presents recent highlights from the shielding and criticality methods development programme that are of relevance to cask design. Specifically, the following points emerge: 1) the preparation of a licence application based upon UK methods and data used in a standardized fissile depletion and plutonium production model has been completed; 2) the assumptions used in the modelling of granules of broken fuel within the transport package following a postulated impact accident have been revised thereby allowing less pessimistic assessments to be performed; 3) enhancements are being made to the software used for shielding and criticality analysis enabling a more cost effective design service to be provided. These ongoing developments clearly show the activity to extend the scope of assessments while increasing the physical realism of the models. Through these developments BNFL continues to offer a comprehensive and cost effective shielding and criticality analysis service as part of its worldwide fuel transport business. (J.P.N.)
An assessment of the lifetime of Faraday shield elements
International Nuclear Information System (INIS)
Caughman, J.B.O. II; Ruzic, D.N.; Hoffman, D.J.; Langley, R.A.; Lewis, M.B.; Ryan, P.M.
1990-01-01
The interaction of plasma with rf fields from an ion cyclotron range of frequencies (ICRF) antenna has been studied to estimate the amount of Faraday shield erosion expected in normal ICRF heating operation. Plasma parameters and ion energies have been measured in the near field of an antenna and used in a model to estimate the erosion rate of the Faraday shield surface. Experiments were conducted on the RF Test Facility, a magnetic mirror device at Oak Ridge National Laboratory, using a single-strap resonant loop antenna with a two-tier Faraday shield. The outer tier, facing the plasma, was layered with graphite tiles. The antenna was operated at currents and voltages within 50% of those expected in tokamaks. The time-varying floating potential was measured with a capacitively coupled probe, and the time-averaged floating potential, electron temperature, and electron density were measured with a Langmuir probe. Ion energies were measured with a gridded energy analyser located below the antenna, and samples of silicon were placed on the Faraday shield surface to estimate the incident ion energy. The capacitive probe measurements show that the rf floating potential follows the magnetic field pattern of the antenna, indicating that the electromagnetic fields are responsible for the potential formation. Plasma parameters and ion energies have been correlated with the antenna current and used in a computational model of the plasma sheath to predict the amount of erosion expected from the Faraday shield elements exposed to plasma. Predictions of light ion sputtering of candidate Faraday shield materials are presented
Heating profiles on ICRF antenna Faraday shields
International Nuclear Information System (INIS)
Taylor, D.J.; Baity, F.W.; Hahs, C.L.; Riemer, B.W.; Ryan, P.M.; Williamson, D.E.
1991-01-01
A conceptual design for an uncooled Faraday shield for the BPX ion cyclotron resonance heating (ICRH) antenna, which should withstand the proposed long-pulse operation, has been completed. A high-heat-flux, uncooled Faraday shield has also been designed for the fast-wave current drive (FWCD) antenna on D3-D. For both components, the improved understanding of the heating profiles made it possible to design for heat fluxes that would otherwise have been too close to mechanically established limits. The analytical effort is described in detail, with emphasis on the design work for the BPX ICRH antenna conceptual design and for the replacement Faraday shield for the D3-D FWCD antenna. Results of analyses are shown, and configuration issues involved in component modeling are discussed. 3 refs., 6 figs., 2 tabs
Gonad shielding in diagnostic radiology
International Nuclear Information System (INIS)
Anon.
1975-01-01
The use of gonad shielding is an important radiation protection technique, intended to reduce unnecessary x-ray exposure of the gonads of patients from diagnostic x-ray procedures. The types of gonad shields in use are discussed as are the types of diagnostic examinations that should include gonad shielding. It was found that when properly used, most shields provided substantial gonad dose reductions
SATIF-2 shielding aspects of accelerators, targets and irradiation facilities
International Nuclear Information System (INIS)
1995-01-01
Particle accelerators have evolved over the last 50 years from simple devices to powerful machines, and will continue to have an important impact on research, technology and lifestyle. Today they cover a wide range of applications, from television and computer displays in households to the investigation of the origin and structure of matter. It has become common practice to use them for material science and medical applications. In recent years, requirements from new technological and research applications have emerged, such as increased particle beams intensities, higher flexibility, etc., giving rise to new radiation shielding aspects and problems. These proceedings review recent progress in radiation shielding of accelerator facilities, and evaluate advancements with respect to international co-operation in this field
International Nuclear Information System (INIS)
Silva, Hugo R.; Silva, Ademir X.; Rebello, Wilson F.; Silva, Maria G.
2011-01-01
This paper aims to present the results obtained by Monte Carlo simulation of the effect of shielding against neutrons, called External Shielding, to be placed on the heads of linear accelerators used in radiotherapy. For this, it was used the radiation transport code Monte Carlo N-Particle - MCNPX, in which were developed computational model of the head of the linear accelerator Varian 2300 C/D. The equipment was simulated within a bunker, operating at energies of 10, 15 and 18 MV, considering the rotation of the gantry at eight different angles ( 0 deg, 45 deg, 90 deg, 135 deg, 180 deg, 225 deg, 270 deg and 315 deg), in all cases, the equipment was modeled without and with the shielding positioned attached to the head of the accelerator on its bottom. In each of these settings, it was calculated the Ambient Dose Equivalent due to neutron H * (10)n on points situated in the region of the patient (region of interest for evaluation of undesirable neutron doses on the patient) and in the maze of radiotherapy room (region of interest for shielding the access door to the bunker). It was observed for all energies of equipment operation as well as for all angles of inclination of the gantry, a significant reduction in the values of H * (10) n when the equipment operated with the external shielding, both in the region of the patient as in the region of the maze. (author)
International Nuclear Information System (INIS)
Robinson, R.A.; Hadden, J.A.; Basham, S.J.
1978-01-01
Preliminary experimental studies of dynamic impact response of scale models of lead-shielded radioactive material shipping containers are presented. The objective of these studies is to provide DOE/ECT with a data base to allow the prediction of a rational margin of confidence in overviewing and assessing the adequacy of the safety and environmental control provided by these shipping containers. Replica scale modeling techniques were employed to predict full scale response with 1/8, 1/4, and 1/2 scale models of shipping containers that are used in the shipment of spent nuclear fuel and high level wastes. Free fall impact experiments are described for scale models of plain cylindrical stainless steel shells, stainless steel shells filled with lead, and replica scale models of radioactive material shipping containers. Dynamic induced strain and acceleration measurements were obtained at several critical locations on the models. The models were dropped from various heights, attitudes to the impact surface, with and without impact limiters and at uniform temperatures between -40 and 175 0 C. In addition, thermal expansion and thermal gradient induced strains were measured at -40 and 175 0 C. The frequency content of the strain signals and the effect of different drop pad compositions and stiffness were examined. Appropriate scale modeling laws were developed and scaling techniques were substantiated for predicting full scale response by comparison of dynamic strain data for 1/8, 1/4, and 1/2 scale models with stainless steel shells and lead shielding
Predictors of Early Community Involvement: Advancing the Self and Caring for Others.
Lawford, Heather L; Ramey, Heather L
2017-03-01
Recent research on community involvement points to the importance of both agentic (advancing the self) and communal motives (serving others) as key predictors, though few studies have examined both simultaneously. At the same time, research has identified generativity, defined as concern for future generations as a legacy of the self, as particularly relevant for community involvement. Moreover, generativity involves both agentic and communal motives, meaning that advancing personal goals and caring for others are integrated in this construct. Therefore, the purpose of this study was to examine how individual differences in attributes pertaining to self and to others-specifically, self-esteem, initiative, and empathy-related to both generativity and community involvement. A sample of adolescents (N = 160; 64% female, M age = 17) and a sample of young adults (N = 237; 84% female, M age = 20) completed a survey including measures of community involvement and generativity. Generative concern fully mediated the associations between individual differences (self-esteem, initiative, and empathy) and community involvement, suggesting that the early generativity has a role in fostering capacities and contribution in youth. These developmental indicators pertaining to self and others link to actions that benefit the community through a desire to benefit future generations. © Society for Community Research and Action 2017.
Comparative study of tungsten and lead as gamma ray shielding material
International Nuclear Information System (INIS)
Wang Jian; Zou Shuliang
2011-01-01
This article firstly compares the tungsten and lead's physical properties, price and environmental performance, then calculates the thickness of tungsten and lead with the gamma ray 10% transmission when the photon energy are 0.1 MeV, 0.2 MeV, 0.5, 1 MeV and 1.25 MeV, and makes a comparison chart. Finally, it establishes a commonly used shielding model, through which to validate whether the thickness of theoretical calculation can achieve an effective shielding effect by MCNP program. The results showers that tungsten as a new type of shielding material has a lot of advantages, which shielding ability is far higher than the lead. Thus it provides the reference to choose the suitable shielding materials in special occasions. (authors)
Application of MCNP code in shielding calculation of minitype fast reactor
International Nuclear Information System (INIS)
He Keyu; Han Weishi
2008-01-01
An accurate shielding calculation model has been set up for the minitype sodium-cooled fast reactor (MFR) based on MCNP code and particular calculation of its primary shielding parameters has been carried out. The results indicate that the photon and neutron flux density of MFR has rapidly fallen to a low-level. The material for the shielding layer outside of main container is primarily of carbon steel, which can be design as a shielding structure satisfying the safety code. The sodium activation in primary circuit is extremely limited and it is simple to shield from. Both the output of helium in reflector and burn up of boron-10 in control rod are very small. These materials can be used for several cycle lives. (authors)
Design experience: CRBRP radiation shielding
International Nuclear Information System (INIS)
Disney, R.K.; Chan, T.C.; Gallo, F.G.; Hedgecock, L.R.; McGinnis, C.A.; Wrights, G.N.
1978-11-01
The Clinch River Breeder Reactor Plant (CRBRP) is being designed as a fast breeder demonstration project in the U.S. Liquid Metal Fast Breeder Reactor (LMFBR) program. Radiation shielding design of the facility consists of a comprehensive design approach to assure compliance with design and government regulatory requirements. Studies conducted during the CRBRP design process involved the aspects of radiation shielding dealing with protection of components, systems, and personnel from radiation exposure. Achievement of feasible designs, while considering the mechanical, structural, nuclear, and thermal performance of the component or system, has required judicious trade-offs in radiation shielding performance. Specific design problems which have been addressed are in-vessel radial shielding to protect permanent core support structures, flux monitor system shielding to isolate flux monitoring systems for extraneous background sources, reactor vessel support shielding to allow personnel access to the closure head during full power operation, and primary heat transport system pipe chaseway shielding to limit intermediate heat transport system sodium system coolant activation. The shielding design solutions to these problems defined a need for prototypic or benchmark experiments to provide assurance of the predicted shielding performance of selected design solutions and the verification of design methodology. Design activities of CRBRP plant components an systems, which have the potential for radiation exposure of plant personnel during operation or maintenance, are controlled by a design review process related to radiation shielding. The program implements design objectives, design requirements, and cost/benefit guidelines to assure that radiation exposures will be ''as low as reasonably achievable''
Žukauskaitėa, A; Plukienė, R; Ridikas, D
2007-01-01
Particle accelerators and other high energy facilities produce penetrating ionizing radiation (neutrons and γ-rays) that must be shielded. The objective of this work was to model photon and neutron transport in various materials, usually used as shielding, such as concrete, iron or graphite. Monte Carlo method allows obtaining answers by simulating individual particles and recording some aspects of their average behavior. In this work several nuclear experiments were modeled: AVF 65 (AVF cyclotron of Research Center of Nuclear Physics, Osaka University, Japan) – γ-ray beams (1-10 MeV), HIMAC (heavy-ion synchrotron of the National Institute of Radiological Sciences in Chiba, Japan) and ISIS-800 (ISIS intensive spallation neutron source facility of the Rutherford Appleton laboratory, UK) – high energy neutron (20-800 MeV) transport in iron and concrete. The calculation results were then compared with experimental data.compared with experimental data.
International Nuclear Information System (INIS)
Mason, Grant W.; Spencer, Ross L.
2002-01-01
The 'self-shielding' m=1 diocotron mode in Malmberg-Penning traps has been known for over a decade to be unstable for finite length nonneutral plasmas with hollow density profiles. Early theoretical efforts were unsuccessful in accounting for the exponential growth and/or the magnitude of the growth rate. Recent theoretical work has sought to resolve the discrepancy either as a consequence of the shape of the plasma ends or as a kinetic effect resulting from a modified distribution function as a consequence of the protocol used to form the hollow profiles in experiments. We have investigated both of these finite length mechanisms in selected test cases using a three-dimensional particle-in-cell code that allows realistic treatment of shape and kinetic effects. We find that a persistent discrepancy of a factor of 2-3 remains between simulation and experimental values of the growth rate
Radiation shielding calculation using MCNP
International Nuclear Information System (INIS)
Masukawa, Fumihiro
2001-01-01
To verify the Monte Carlo code MCNP4A as a tool to generate the reference data in the shielding designs and the safety evaluations, various shielding benchmark experiments were analyzed using this code. These experiments were categorized in three types of the shielding subjects; bulk shielding, streaming, and skyshine. For the variance reduction technique, which is indispensable to get meaningful results with the Monte Carlo shielding calculation, we mainly used the weight window, the energy dependent Russian roulette and spitting. As a whole, our analyses performed enough small statistical errors and showed good agreements with these experiments. (author)
MMW [multimegawatt] shielding design and analysis
International Nuclear Information System (INIS)
Olson, A.P.
1988-01-01
Reactor shielding for multimegawatt (MMW) space power must satisfy a mass constraint as well as performance specifications for neutron fluence and gamma dose. A minimum mass shield is helpful in attaining the launch mass goal for the entire vehicle, because the shield comprises about 1% to 2% of the total vehicle mass. In addition, the shield internal heating must produce tolerable temperatures. The analysis of shield performance for neutrons and gamma rays is emphasized. Topics addressed include cross section preparation for multigroup 2D S/sub n/-transport analyses, and the results of parametric design studies on shadow shield performance and mass versus key shield design variables such as cone angle, number, placement, and thickness of layers of tungsten, and shield top radius. Finally, adjoint methods are applied to the shield in order to spatially map its relative contribution to dose reduction, and to provide insight into further design optimization. 7 refs., 2 figs., 3 tabs
Some geological effects of the search for radioactive minerals in the Canadian shield
International Nuclear Information System (INIS)
Lang, A.H.; Ruzicka, V.
1979-01-01
Priorities for funds and personnel to provide field and laboratory work related to finding and evaluating radioactive deposits, mainly those of uranium, also led directly and indirectly to greatly increased knowledge of the general geology of the Canadian Shield. The paper outlines some of the main advances made in these ways, as well as some minor ones. Main examples are: the acceleration of geological mapping and special studies of stratigraphy, structure and other aspects of several parts of the Shield, including the Archaean-Proterozoic boundary; the acquisition of modern equipment capable of making large numbers of isotope age determinations, which was soon applied to general problems in the Shield, including revision of its regional provinces and sub-provinces and the subdivision of Proterozoic time; the obtaining of modern equipment for X-ray identification of minerals and for several kinds of rock and mineral analyses, which soon allowed more advanced and more extensive mineral, petrological and trace element studies of various parts of the Shield and a general study of metallogenic provinces, illustrated by metallogenic maps, which stemmed from a metallogenic map for uranium. The development of Geiger counters and other detectors is outlined because of their relation to the map for uranium and so to aeroradiometric surveys. By 1960, 26 producing uranium mines had been developed from an estimated 12 000 occurrences carrying more than 0.05% U 3 O 8 equivalent. Current activities of the Geological Survey of Canada for radioactive minerals are summarized for whatever hints this may provide regarding further indirect effects
International Nuclear Information System (INIS)
Schmidt-Bleker, A; Winter, J; Iseni, S; Dünnbier, M; Reuter, S; Weltmann, K-D
2014-01-01
In this work, a simple modelling approach combined with absorption spectroscopy of long living species generated by a cold atmospheric plasma jet yields insight into relevant gas phase chemistry. The reactive species output of the plasma jet is controlled using a shielding gas device. The shielding gas is varied using mixtures of oxygen and nitrogen at various humidity levels. Through the combination of Fourier transform infrared (FTIR) spectroscopy, computational fluid dynamics (CFD) simulations and zero dimensional kinetic modelling of the gas phase chemistry, insight into the underlying reaction mechanisms is gained. While the FTIR measurements yield absolute densities of ozone and nitrogen dioxide in the far field of the jet, the kinetic simulations give additional information on reaction pathways. The simulation is fitted to the experimentally obtained data, using the CFD simulations of the experimental setup to estimate the correct evaluation time for the kinetic simulation. It is shown that the ozone production of the plasma jet continuously rises with the oxygen content in the shielding gas, while it significantly drops as humidity is increased. The production of nitrogen dioxide reaches its maximum at about 30% oxygen content in the shielding gas. The underlying mechanisms are discussed based on the simulation results. (paper)
International Nuclear Information System (INIS)
Schnick, M; Lohse, M; Fuessel, U; Wilhelm, G; Murphy, A B
2011-01-01
The paper presents a transient three-dimensional model of an anti-phase-synchronized pulsed tandem gas-metal arc welding process, which is used to analyse arc interactions and their influence on the gas shield flow. The shielding gases considered are pure argon and a mixture of argon with 18% CO 2 . Comparison of the temperature fields predicted by the model with high-speed images indicates that the essential features of the interactions between the arcs are captured. The paper demonstrates strong arc deflection and kinking, especially during the low-current phase of the pulse, in agreement with experimental observations. These effects are more distinct for the argon mixture with 18% CO 2 . The second part of the paper demonstrates the effects of arc deflection and instabilities on the shielding gas flow and the occurrence of air contamination in the process region. The results allow an improved understanding of the causes of periodic instabilities and weld seam imperfections such as porosity, spatter, heat-tint oxidation and fume deposits.
Xu, Wei; Zhou, Yuyang; Fu, Zhongfang; Rodriguez, Marcus
2017-12-01
Previous studies have shown that dispositional mindfulness is associated with less psychological symptoms in cancer patients. The present study investigated how dispositional mindfulness is related to psychological symptoms in advanced gastrointestinal cancer patients by considering the roles of self-acceptance and perceived stress. A total of 176 patients with advanced gastrointestinal cancer were recruited to complete a series of questionnaires including Mindfulness Attention Awareness Scale, Self-acceptance Questionnaire, Chinese Perceived Stress Scale, and General Health Questionnaire. Results showed that the proposed model fitted the data very well (χ 2 = 7.564, df = 7, P = .364, χ 2 /df = 1.094, Goodness of Fit Index (GFI) = 0.986, Comparative Fit Index (CFI) = 0.998, Tucker Lewis Index (TLI) = 0.995, Root Mean Square Error of Approximation (RMSEA) = 0.023). Further analyses revealed that, self-acceptance and perceived stress mediated the relation between dispositional mindfulness and psychological symptoms (indirect effect = -0.052, 95% confidence interval = -0.087 ~ -0.024), while self-acceptance also mediated the relation between dispositional mindfulness and perceived stress (indirect effect = -0.154, 95% confidence interval = -0.261 ~ -0.079). Self-acceptance and perceived stress played critical roles in the relation between dispositional mindfulness and psychological symptoms. Limitations, clinical implications, and directions for future research were discussed. Copyright © 2017 John Wiley & Sons, Ltd.
Singh, Rajender; Sharma, Ramesh; Barman, P. B.; Sharma, Dheeraj
2017-11-01
UV shielding based super hydrophilic material is developed in the present formulation by in situ emulsion polymerization of poly (styrene-acrylonitrile) with ZnO nanoparticles. The ESI-MS technique confirms the structure of polymer nanocomposite by their mass fragments. The XRD study confirms the presence of ZnO phase in polymer matrix. PSAN/ZnO nanocomposite leads to give effective UV shielding (upto 375 nm) and visible luminescence with ZnO content in polymer matrix. The FESEM and TEM studies confirm the symmetrical, controlled growth of PNs. The incorporation of ZnO nanofillers into PSAN matrix lead to restructuring the PNs surfaces into superhydrophilic surfaces in water contact angle (WCA) from 70° to 10°. We believe our synthesized PSAN/ZnO nanocomposite could be potential as UV shielding, luminescent and super hydrophilic nature based materials in related commercial applications.
Status of the ITER tokamak nuclear shielding and radiological protection design
Energy Technology Data Exchange (ETDEWEB)
Leichtle, D., E-mail: dieter.leichtle@f4e.europa.eu [Fusion for Energy, Josep Pla 2, Barcelona 08019 (Spain); Chaffard, P.Y.; Izquierdo, J. [Fusion for Energy, Josep Pla 2, Barcelona 08019 (Spain); Juarez, R. [UNED, Juan del Rosal 12, Madrid 28040 (Spain); Pampin, R.; Portone, A. [Fusion for Energy, Josep Pla 2, Barcelona 08019 (Spain)
2016-11-01
Highlights: • Comprehensive review of design status of the ITER tokamak regarding nuclear shielding. • Investigation of shield design options and streaming mitigation measures. • Review of state-of-the-art shutdown dose rate analyses for selected port systems. - Abstract: Nuclear shielding of the ITER tokamak encompasses several systems and interfaces in a complex radiation environment. Therefore any shielding design has to involve a series of structures, systems and components in an integrated approach. This is evident for the complex ex-vessel radiation environment with streaming and leakage of plasma neutrons and subsequent activation of ex-vessel structures which give raise to excessive shutdown dose rates in accessible areas of the cryostat. The paper reviews recent nuclear analyses related to the performance of primary shields and highlights challenges toward an integrated nuclear shielding design. The general need of propagation of shielding requirements is highlighted in the context of radiation cross talk due to penetrations. Radiation streaming through gaps and penetrations is a key problem in any efficient shield design. The impact on the evolving radiation environment due to several design options along streaming paths such as port gaps, as well as their modeling for nuclear analysis, is presented. Implications regarding design integration and compliance with integrated shielding requirements and ALARA dose are finally given.
LOFT shield tank steady state temperatures with addition of gamma and neutron shielding
International Nuclear Information System (INIS)
Kyllingstad, G.
1977-01-01
The effect of introducing a neutron and gamma shield into the annulus between the reactor vessel and the shield tank is analyzed. This addition has been proposed in order to intercept neutron streaming up the annulus during nuclear operations. Its installation will require removal of approximately 20- 1 / 2 inches of stainless steel foil insulation at the top of the annulus. The resulting conduction path is believed to result in increased water temperatures within the shield tank, possibly beyond the 150 0 F limit, and/or cooling of the reactor vessel nozzles such that adverse thermal stresses would be generated. A two dimensional thermal analysis using the finite element code COUPLE/MOD2 was done for the shield tank system illustrated in the figure (1). The reactor was assumed to be at full power, 55 MW (th), with a loop flow rate of 2.15 x 10 6 lbm/hr (268.4 kg/s) at 2250 psi (15.51 MPa). Calculations indicate a steady state shield tank water temperature of 140 0 F (60 0 C). This is below the 150 0 F (65.56 0 C) limit. Also, no significant changes in thermal gradients within the nozzle or reactor vessel wall are generated. A spacer between the gamma shield and the shield tank is recommended, however, in order to ensure free air circulation through the annulus
Application of Interval Predictor Models to Space Radiation Shielding
Crespo, Luis G.; Kenny, Sean P.; Giesy,Daniel P.; Norman, Ryan B.; Blattnig, Steve R.
2016-01-01
This paper develops techniques for predicting the uncertainty range of an output variable given input-output data. These models are called Interval Predictor Models (IPM) because they yield an interval valued function of the input. This paper develops IPMs having a radial basis structure. This structure enables the formal description of (i) the uncertainty in the models parameters, (ii) the predicted output interval, and (iii) the probability that a future observation would fall in such an interval. In contrast to other metamodeling techniques, this probabilistic certi cate of correctness does not require making any assumptions on the structure of the mechanism from which data are drawn. Optimization-based strategies for calculating IPMs having minimal spread while containing all the data are developed. Constraints for bounding the minimum interval spread over the continuum of inputs, regulating the IPMs variation/oscillation, and centering its spread about a target point, are used to prevent data over tting. Furthermore, we develop an approach for using expert opinion during extrapolation. This metamodeling technique is illustrated using a radiation shielding application for space exploration. In this application, we use IPMs to describe the error incurred in predicting the ux of particles resulting from the interaction between a high-energy incident beam and a target.
Concrete shielding for nuclear ship 'Mutsu'
International Nuclear Information System (INIS)
Nagase, Tetsuo; Nakajima, Tadao; Okumura, Tadahiko; Saito, Tetsuo
1983-01-01
The nuclear ship ''Mutsu'' was constructed in 1970 as the fourth in the world. On September 1, 1974, during the power raising test in the Pacific Ocean, radiation leak was detected. As the result of investigation, it was found that the cause was the fast neutrons streaming through the gap between the reactor pressure vessel and the primary shield. In order to repair the shielding facility, the Japan Nuclear Ship Research Development Agency carried out research and development and shielding design. It was decided to adopt serpentine concrete for the primary shield, which is the excellent moderator of fast neutrons even at high temperature, and heavy concrete for the secondary shield, which is effective for shielding both gamma ray and neutron beam. The repair of shielding was carried out in the Sasebo Shipyard, and completed in August, 1982. The outline of the repair work is reported. The weight increase was about 300 t. The conditions of the shielding design, the method of shielding analysis, the performance required for the shielding concrete, the preliminary experiment on heavy concrete and the construction works of serpentine concrete and heavy concrete are described. (Kako, I.)
Accelerator shielding benchmark problems
International Nuclear Information System (INIS)
Hirayama, H.; Ban, S.; Nakamura, T.
1993-01-01
Accelerator shielding benchmark problems prepared by Working Group of Accelerator Shielding in the Research Committee on Radiation Behavior in the Atomic Energy Society of Japan were compiled by Radiation Safety Control Center of National Laboratory for High Energy Physics. Twenty-five accelerator shielding benchmark problems are presented for evaluating the calculational algorithm, the accuracy of computer codes and the nuclear data used in codes. (author)
International Nuclear Information System (INIS)
Koike, Hiroki; Kirimura, Kazuki; Yamaji, Kazuya; Kosaka, Shinya; Yamamoto, Akio
2018-01-01
A unified resonance self-shielding method, which can treat general sub-divided fuel regions, is developed for lattice physics calculations in reactor physics field. In a past study, a hybrid resonance treatment has been developed by theoretically integrating equivalence theory and ultra-fine-group slowing-down calculation. It can be applied to a wide range of neutron spectrum conditions including low moderator density ranges in severe accident states, as long as each fuel region is not sub-divided. In order to extend the method for radially and azimuthally sub-divided multi-region geometry, a new resonance treatment is established by incorporating the essence of sub-group method. The present method is composed of two-step flux calculation, i.e. 'coarse geometry + fine energy' (first step) and 'fine geometry + coarse energy' (second step) calculations. The first step corresponds to a hybrid model of the equivalence theory and the ultra-fine-group calculation, and the second step corresponds to the sub-group method. From the verification results, effective cross-sections by the new method show good agreement with the continuous energy Monte-Carlo results for various multi-region geometries including non-uniform fuel compositions and temperature distributions. The present method can accurately generate effective cross-sections with short computation time in general lattice physics calculations. (author)
HPGe detector shielding adjustment
International Nuclear Information System (INIS)
Trnkova, L.; Rulik, P.
2008-01-01
Low-level background shielding of HPGe detectors is used mainly for environmental samples with very low content of radionuclides. National Radiation Protection Institute (SURO) in Prague is equipped with 14 HPGe detectors with relative efficiency up to 150%. The detectors are placed in a room built from materials with low content of natural radionuclides and equipped with a double isolation of the floor against radon. Detectors themselves are placed in lead or steel shielding. Steel shielding with one of these detectors with relative efficiency of 100% was chosen to be rebuilt to achieve lower minimum detectable activity (MDA). Additional lead and copper shielding was built up inside the original steel shielding to reduce the volume of the inner space and filled with nitrogen by means of evaporating liquid nitrogen. The additional lead and copper shielding, consequent reduction of the inner volume and supply of evaporated nitrogen, caused a decrease of the background count and accordingly MDA values as well. The effect of nitrogen evaporation on the net areas of peaks belonging to radon daughters is significant. The enhanced shielding adjustment has the biggest influence in low energy range, what can be seen in collected data. MDA values in energy range from 30 keV to 400 keV decreased to 0.65-0.85 of original value, in energy range from 400 keV to 2 MeV they fell to 0.70-0.97 of original value. (authors)
Shielding design of radioactive contaminated metal waste packaging
International Nuclear Information System (INIS)
Zou Wenhua; Dong Zhiqiang; Yao Zhenyu; Xu Shuhe; Wang Wen
2015-01-01
Focusing on the cylindrical source model to calculate γ dose field of waste packages with the relative formulae then derived. By comparing the calculated data of waste packages of type Ⅷ steel box with the monitoring data, it is found that the cylinder source model could accurately reflect the distributions of γ dose of the waste package. Based on the results of the cylindrical source model, a reasonable shielding technology applicable to waste package containers was designed to meet relevant requirements prescribed in standards about the transport and disposal of radioactive materials. The cylinder source model calculated dose distributions for single package in this paper is simple and easy to implement but slightly larger than the monitoring data providing a certain safety margin for the shielding design. It is suitable for radiological engineering practices. (authors)
External dosimetry sources and shielding
International Nuclear Information System (INIS)
Calisto, Washington
1994-01-01
A definition of external dosimetry r external sources dosimetry,physical and mathematical treatment of the interaction of gamma radiation with a minimal area in that direction. Concept of attenuation coefficient, cumulated effect by polyenergetic sources, exposition rate, units, cumulated dose,shielding, foton shielding, depth calculation, materials used for shielding.Beta shielding, consideration of range and maximum β energy , low stopping radiation by use of low Z shielding. Tables for β energy of β emitters, I (tau) factor, energy-range curves for β emitters in aqueous media, gamma attenuation factors for U, W and Pb. Y factor for bone tissue,muscle and air, build-up factors
Energy Technology Data Exchange (ETDEWEB)
Rios, D.A.S.; Rios, P.B., E-mail: denise@inovafi.com.br [Inovafi Física aplicada à Inovação Ltda, Sorocaba, SP (Brazil); Sordi, G.M.A.A.; Carneiro, J.C.G.G. [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil)
2017-07-01
The study discusses situations in the industrial environment that may lead to potential exposure of Occupationally Exposed Individuals and Public Individuals in self-shielding electron accelerators. Although these exposure situations are unlikely, simulation exercises can lead to improvements in the operating procedure as well as suggest changes in production line design in order to increase radiation protection at work. These studies can also be used in training and demonstrate a solid application of the ALARA principle in the daily activities of radiative installations.
Method for dismantling shields
International Nuclear Information System (INIS)
Fukuzawa, Rokuro; Kondo, Nobuhiro; Kamiyama, Yoshinori; Kawasato, Ken; Hiraga, Tomoaki.
1990-01-01
The object of the present invention is to enable operators to dismantle shieldings contaminated by radioactivity easily and in a short period of time without danger of radiation exposure. A plurality of introduction pipes are embedded previously to the shielding walls of shielding members which contain a reactor core in a state where both ends of the introduction pipes are in communication with the outside. A wire saw is inserted into the introduction pipes to cut the shieldings upon dismantling. Then, shieldings can be dismantled easily in a short period of time with no radiation exposure to operator's. Further, according to the present invention, since the wire saw can be set easily and a large area can be cut at once, operation efficiency is improved. Further, since remote control is possible, cutting can be conducted in water and complicated places of the reactor. Biting upon starting the wire saw in the introduction pipe is reduced to facilitate startup for the rotation. (I.S.)
International Nuclear Information System (INIS)
Terauchi, N.; Noguchi, S.; Igarashi, H.
2011-01-01
A superconducting film shield over a SQUID ring improves the robustness of the SQUID with respect to magnetic noise. Supercurrent in the SQUID magnetometer and the superconducting film shield were simulated. The superconducting film shield reduces the influence of the external magnetic field on the SQUID ring. An HTS SQUID is a high sensitive magnetic sensor. In recent years, the HTS SQUID is widely used in various applications. In some applications, high robustness with respect to magnetic noise is required to realize stable operation at outside of a magnetic shielding room. The target of this paper is a directly coupled HTS dc-SQUID magnetometer. To enhance the robustness of the SQUID magnetometer, use of a superconducting thin film shield has been proposed. The magnetic field directly penetrating the SQUID ring causes the change of the critical current of Josephson junction, and then the SQUID magnetometer transitions into inoperative state. In order to confirm the magnetic shield effect of the superconducting film shield, electromagnetic field simulation with 3D edge finite element method was performed. To simulate the high temperature superconductor, E-J characteristics and c-axis anisotropy are considered. To evaluate the effect of the superconducting film shield, an external magnetic field which is supposed to be a magnetic noise is applied. From the simulation results, the time transition of the magnetic flux penetrating the SQUID ring is investigated and the effect of the superconducting film shield is confirmed. The amplitude of the magnetic flux penetrating the SQUID ring can be reduced to about one-sixth since the superconducting film shield prevents the magnetic noise from directly penetrating the SQUID ring.
Iwamoto, Hiroki; Meigo, Shin-ichiro
2017-09-01
The impact of different spallation models implemented in the particle transport code PHITS on the shielding design of Transmutation Experimental Facility is investigated. For 400-MeV proton incident on a lead-bismuth eutectic target, an effective dose rate at the end of a thick radiation shield (3-m-thick iron and 3-m-thick concrete) calculated by the Liège intranuclear cascade (INC) model version 4.6 (INCL4.6) coupled with the GEMcode (INCL4.6/GEM) yields about twice as high as the Bertini INC model (Bertini/GEM). A comparison with experimental data for 500-MeV proton incident on a thick lead target suggest that the prediction accuracy of INCL4.6/GEM would be better than that of Bertini/GEM. In contrast, it is found that the dose rates in beam ducts in front of targets calculated by the INCL4.6/GEMare lower than those by the Bertini/GEM. Since both models underestimate the experimental results for neutron-production doubledifferential cross sections at 180° for 140-MeV proton incident on carbon, iron, and gold targets, it is concluded that it is necessary to allow a margin for uncertainty caused by the spallation models, which is a factor of two, in estimating the dose rate induced by neutron streaming through a beam duct.
Space Shuttle Orbiter AFT heat shield seal
Walkover, L. J.
1979-01-01
The evolution of the orbiter aft heat shield seal (AHSS) design, which involved advancing mechanical seal technology in severe thermal environment is discussed. The baseline design, various improvements for engine access, and technical problem solution are presented. It is a structure and mechanism at the three main propulsion system (MPS) engine interfaces to the aft compartment structure. Access to each MPS engine requires disassembly and removal of the AHSS. Each AHSS accommodates the engine movement, is exposed to an extremely high temperature environment, and is part of the venting control of the aft compartment.
Thermal-hydraulic analysis and design improvement for coolant channel of ITER shield block
International Nuclear Information System (INIS)
Zhao Ling; Li Huaqi; Zheng Jiantao; Yi Jingwei; Kang Weishan; Chen Jiming
2013-01-01
As an important part for ITER, shield block is used to shield the neutron heat. The structure design of shield block, especially the inner coolant channel design will influence its cooling effect and safety significantly. In this study, the thermal-hydraulic analysis for shield block has been performed by the computational fluid dynamics software, some optimization suggestions have been proposed and thermal-hydraulic characteristics of the improved model has been analyzed again. The analysis results for improved model show that pressure drop through flow path near the inlet and outlet region of the shield block has been reduced, and the total pressure drop in cooling path has been reduced too; the uniformity of the mass flowrate distribution and the velocity distribution have been improved in main cooling branches; the local highest temperature of solid domain reduced considerably, which could avoid thermal stress becoming too large because of coolant effect unevenly. (authors)
Li, Ping; Shi, Yifei; Jiang, Li Jun; Bagci, Hakan
2016-01-01
, in this paper, a novel approach is proposed to model the radiated emission from electronic devices placed in shielding enclosures by using the near electric field only. Based on the Schelkkunoff’s equivalence principle and Raleigh–Carson reciprocity theorem
Scintillation counter, segmented shield
International Nuclear Information System (INIS)
Olson, R.E.; Thumim, A.D.
1975-01-01
A scintillation counter, particularly for counting gamma ray photons, includes a massive lead radiation shield surrounding a sample-receiving zone. The shield is disassembleable into a plurality of segments to allow facile installation and removal of a photomultiplier tube assembly, the segments being so constructed as to prevent straight-line access of external radiation through the shield into radiation-responsive areas. Provisions are made for accurately aligning the photomultiplier tube with respect to one or more sample-transmitting bores extending through the shield to the sample receiving zone. A sample elevator, used in transporting samples into the zone, is designed to provide a maximum gamma-receiving aspect to maximize the gamma detecting efficiency. (U.S.)
Thermal Analysis of a SHIELD Electromigration Test Structure
Energy Technology Data Exchange (ETDEWEB)
Benson, David A.; Bowman, Duane J.; Mitchell, Robert T.
1999-05-01
The steady state and transient thermal behavior of an electromigration test structure was analyzed. The test structure was a Sandia SHIELD (Self-stressing HIgh fregquency rELiability Device) electromigration test device manufactured by an outside vendor. This device has a high frequency oscillator circuit, a buffer circuit to isolate and drive the metal line to the tested (DUT), the DUT to be electromigrated itself, a metal resistance thermometry monitor, and a heater elment to temperature accelerate the electromigration effect.
Capsule Shields the Function of Short Bacterial Adhesins
Schembri, Mark A.; Dalsgaard, Dorte; Klemm, Per
2004-01-01
Bacterial surface structures such as capsules and adhesins are generally regarded as important virulence factors. Here we demonstrate that capsules block the function of the self-recognizing protein antigen 43 through physical shielding. The phenomenon is not restricted to Escherichia coli but can occur in other gram-negative bacteria. Likewise, we show that other short adhesins exemplified by the AIDA-I protein are blocked by the presence of a capsule. The results support the notion that cap...
SHIELDS Final Technical Report
Energy Technology Data Exchange (ETDEWEB)
Jordanova, Vania Koleva [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)
2017-10-03
Predicting variations in the near-Earth space environment that can lead to spacecraft damage and failure, i.e. “space weather”, remains a big space physics challenge. A new capability was developed at Los Alamos National Laboratory (LANL) to understand, model, and predict Space Hazards Induced near Earth by Large Dynamic Storms, the SHIELDS framework. This framework simulates the dynamics of the Surface Charging Environment (SCE), the hot (keV) electrons representing the source and seed populations for the radiation belts, on both macro- and micro-scale. In addition to using physics-based models (like RAM-SCB, BATS-R-US, and iPIC3D), new data assimilation techniques employing data from LANL instruments on the Van Allen Probes and geosynchronous satellites were developed. An order of magnitude improvement in the accuracy in the simulation of the spacecraft surface charging environment was thus obtained. SHIELDS also includes a post-processing tool designed to calculate the surface charging for specific spacecraft geometry using the Curvilinear Particle-In-Cell (CPIC) code and to evaluate anomalies' relation to SCE dynamics. Such diagnostics is critically important when performing forensic analyses of space-system failures.
Micrometeoroid and Orbital Debris (MMOD) Shield Ballistic Limit Analysis Program
Ryan, Shannon
2013-01-01
This software implements penetration limit equations for common micrometeoroid and orbital debris (MMOD) shield configurations, windows, and thermal protection systems. Allowable MMOD risk is formulated in terms of the probability of penetration (PNP) of the spacecraft pressure hull. For calculating the risk, spacecraft geometry models, mission profiles, debris environment models, and penetration limit equations for installed shielding configurations are required. Risk assessment software such as NASA's BUMPERII is used to calculate mission PNP; however, they are unsuitable for use in shield design and preliminary analysis studies. The software defines a single equation for the design and performance evaluation of common MMOD shielding configurations, windows, and thermal protection systems, along with a description of their validity range and guidelines for their application. Recommendations are based on preliminary reviews of fundamental assumptions, and accuracy in predicting experimental impact test results. The software is programmed in Visual Basic for Applications for installation as a simple add-in for Microsoft Excel. The user is directed to a graphical user interface (GUI) that requires user inputs and provides solutions directly in Microsoft Excel workbooks.
EBT-P gamma-ray-shielding analysis
International Nuclear Information System (INIS)
Gohar, Y.
1983-01-01
First, a one-dimensional scoping study was performed for the gamma-ray shield of the ELMO Bumpy Torus proof-of-principle device to define appropriate shielding material and determine the required shielding thickness. The dose-equivalent results are analyzed as a function of the radiation-shield thickness for different shielding options. A sensitivity analysis for the pessimistic case is given. The recommended shielding option based on the performance and cost is discussed. Next, a three-dimensional scoping study for the coil shield was performed for four different shielding options to define the heat load for each component and check the compliance with the design criterion of 10 watts maximum heat load per coil from the gamma-ray sources. Also, a detailed biological-dose survey was performed which included: (a) the dose equivalent inside and outside the building, (b) the dose equivalent from the two mazes of the building, and (c) the skyshine contribution to the dose equivalent
Creel, T. R.; Beckwith, I. E.
1983-01-01
A method of shielding a wind-tunnel model from noise radiated by the tunnel-wall boundary layer has been developed and tested at the Langley Research Center. The shield consists of a rectangular array of longitudinal rods with boundary-layer suction through gaps between the rods. Tests were conducted at Mach 5 over a unit Reynolds number range of 1.0-3.5 x 10 to the 7th/m. Hot-wire measurements indicated the freestream noise, expressed in terms of the rms pressure fluctuations normalized by the mean pressure, was reduced from about 1.4 percent just upstream of the shielded region of a minimum level of about 0.4 percent in the forward portion of the shielded flow.
Dickson, E D; Hamby, D M
2014-03-01
The human health and environmental effects following a postulated accidental release of radioactive material to the environment have been a public and regulatory concern since the early development of nuclear technology. These postulated releases have been researched extensively to better understand the potential risks for accident mitigation and emergency planning purposes. The objective of this investigation is to provide an updated technical basis for contemporary building shielding factors for the US housing stock. Building shielding factors quantify the protection from ionising radiation provided by a certain building type. Much of the current data used to determine the quality of shielding around nuclear facilities and urban environments is based on simplistic point-kernel calculations for 1950s era suburbia and is no longer applicable to the densely populated urban environments realised today. To analyse a building's radiation shielding properties, the ideal approach would be to subject a variety of building types to various radioactive sources and measure the radiation levels in and around the building. While this is not entirely practicable, this research analyses the shielding effectiveness of ten structurally significant US housing-stock models (walls and roofs) important for shielding against ionising radiation. The experimental data are used to benchmark computational models to calculate the shielding effectiveness of various building configurations under investigation from two types of realistic environmental source terms. Various combinations of these ten shielding models can be used to develop full-scale computational housing-unit models for building shielding factor calculations representing 69.6 million housing units (61.3%) in the United States. Results produced in this investigation provide a comparison between theory and experiment behind building shielding factor methodology.
International Nuclear Information System (INIS)
Dickson, E D; Hamby, D M
2014-01-01
The human health and environmental effects following a postulated accidental release of radioactive material to the environment have been a public and regulatory concern since the early development of nuclear technology. These postulated releases have been researched extensively to better understand the potential risks for accident mitigation and emergency planning purposes. The objective of this investigation is to provide an updated technical basis for contemporary building shielding factors for the US housing stock. Building shielding factors quantify the protection from ionising radiation provided by a certain building type. Much of the current data used to determine the quality of shielding around nuclear facilities and urban environments is based on simplistic point-kernel calculations for 1950s era suburbia and is no longer applicable to the densely populated urban environments realised today. To analyse a building’s radiation shielding properties, the ideal approach would be to subject a variety of building types to various radioactive sources and measure the radiation levels in and around the building. While this is not entirely practicable, this research analyses the shielding effectiveness of ten structurally significant US housing-stock models (walls and roofs) important for shielding against ionising radiation. The experimental data are used to benchmark computational models to calculate the shielding effectiveness of various building configurations under investigation from two types of realistic environmental source terms. Various combinations of these ten shielding models can be used to develop full-scale computational housing-unit models for building shielding factor calculations representing 69.6 million housing units (61.3%) in the United States. Results produced in this investigation provide a comparison between theory and experiment behind building shielding factor methodology. (paper)
LOW-FREQUENCY MAGNETIC FIELD SHIELDING BY A CIRCULAR PASSIVE LOOP AND CLOSED SHELLS
Directory of Open Access Journals (Sweden)
V.S. Grinchenko
2016-05-01
Full Text Available Purpose. To analyze the shielding factors for a circular passive loop and conductive closed shells placed in a homogeneous low-frequency magnetic field. Methodology. We have obtained simplified expressions for the shielding factors for a circular passive loop and a thin spherical shell. In addition, we have developed the numerical model of a thin cubical shell in a magnetic field, which allows exploring its shielding characteristics. Results. We have obtained dependences of the shielding factors for passive loops and shells on the frequency of the external field. Analytically determined frequency of the external magnetic field, below which field shielding of a passive loop is expedient to use, above which it is advisable to use a shielding shell.
FISPACT-II: An Advanced Simulation System for Activation, Transmutation and Material Modelling
Energy Technology Data Exchange (ETDEWEB)
Sublet, J.-Ch., E-mail: jean-christophe.sublet@ukaea.uk [United Kingdom Atomic Energy Authority, Culham Science Centre, Abingdon OX14 3DB (United Kingdom); Eastwood, J.W.; Morgan, J.G. [Culham Electromagnetics Ltd, Culham Science Centre, Abingdon OX14 3DB (United Kingdom); Gilbert, M.R.; Fleming, M.; Arter, W. [United Kingdom Atomic Energy Authority, Culham Science Centre, Abingdon OX14 3DB (United Kingdom)
2017-01-15
Fispact-II is a code system and library database for modelling activation-transmutation processes, depletion-burn-up, time dependent inventory and radiation damage source terms caused by nuclear reactions and decays. The Fispact-II code, written in object-style Fortran, follows the evolution of material irradiated by neutrons, alphas, gammas, protons, or deuterons, and provides a wide range of derived radiological output quantities to satisfy most needs for nuclear applications. It can be used with any ENDF-compliant group library data for nuclear reactions, particle-induced and spontaneous fission yields, and radioactive decay (including but not limited to TENDL-2015, ENDF/B-VII.1, JEFF-3.2, JENDL-4.0u, CENDL-3.1 processed into fine-group-structure files, GEFY-5.2 and UKDD-16), as well as resolved and unresolved resonance range probability tables for self-shielding corrections and updated radiological hazard indices. The code has many novel features including: extension of the energy range up to 1 GeV; additional neutron physics including self-shielding effects, temperature dependence, thin and thick target yields; pathway analysis; and sensitivity and uncertainty quantification and propagation using full covariance data. The latest ENDF libraries such as TENDL encompass thousands of target isotopes. Nuclear data libraries for Fispact-II are prepared from these using processing codes PREPRO, NJOY and CALENDF. These data include resonance parameters, cross sections with covariances, probability tables in the resonance ranges, PKA spectra, kerma, dpa, gas and radionuclide production and energy-dependent fission yields, supplemented with all 27 decay types. All such data for the five most important incident particles are provided in evaluated data tables. The Fispact-II simulation software is described in detail in this paper, together with the nuclear data libraries. The Fispact-II system also includes several utility programs for code-use optimisation
Engineering modeling of traffic noise in shielded areas in cities.
Salomons, Erik M; Polinder, Henk; Lohman, Walter J A; Zhou, Han; Borst, Hieronymous C; Miedema, Henk M E
2009-11-01
A computational study of road traffic noise in cities is presented. Based on numerical boundary-element calculations of canyon-to-canyon propagation, an efficient engineering algorithm is developed to calculate the effect of multiple reflections in street canyons. The algorithm is supported by a room-acoustical analysis of the reverberant sound fields in the source and receiver canyons. Using the algorithm, a simple model for traffic noise in cities is developed. Noise maps and exposure distributions of the city of Amsterdam are calculated with the model, and for comparison also with an engineering model that is currently used for traffic noise impact assessments in cities. Considerable differences between the two model predictions are found for shielded buildings with day-evening-night levels of 40-60 dB at the facades. Further, an analysis is presented of level differences between the most and the least exposed facades of buildings. Large level differences are found for buildings directly exposed to traffic noise from nearby roads. It is shown that by a redistribution of traffic flow around these buildings, one can achieve low sound levels at quiet sides and a corresponding reduction in the percentage of highly annoyed inhabitants from typically 23% to 18%.
Parameters calculation of shielding experiment
International Nuclear Information System (INIS)
Gavazza, S.
1986-02-01
The radiation transport methodology comparing the calculated reactions and dose rates for neutrons and gama-rays, with experimental measurements obtained on iron shield, irradiated in the YAYOI reactor is evaluated. The ENDF/B-IV and VITAMIN-C libraries and the AMPX-II modular system, for cross sections generation collapsed by the ANISN code were used. The transport calculations were made using the DOT 3.5 code, adjusting the boundary iron shield source spectrum to the reactions and dose rates, measured at the beginning of shield. The neutron and gamma ray distributions calculated on the iron shield presented reasonable agreement with experimental measurements. An experimental arrangement using the IEA-R1 reactor to determine a shielding benchmark is proposed. (Author) [pt
Morphometry of terrestrial shield volcanoes
Grosse, Pablo; Kervyn, Matthieu
2018-03-01
Shield volcanoes are described as low-angle edifices built primarily by the accumulation of successive lava flows. This generic view of shield volcano morphology is based on a limited number of monogenetic shields from Iceland and Mexico, and a small set of large oceanic islands (Hawaii, Galápagos). Here, the morphometry of 158 monogenetic and polygenetic shield volcanoes is analyzed quantitatively from 90-meter resolution SRTM DEMs using the MORVOLC algorithm. An additional set of 24 lava-dominated 'shield-like' volcanoes, considered so far as stratovolcanoes, are documented for comparison. Results show that there is a large variation in shield size (volumes from 0.1 to > 1000 km3), profile shape (height/basal width (H/WB) ratios mostly from 0.01 to 0.1), flank slope gradients (average slopes mostly from 1° to 15°), elongation and summit truncation. Although there is no clear-cut morphometric difference between shield volcanoes and stratovolcanoes, an approximate threshold can be drawn at 12° average slope and 0.10 H/WB ratio. Principal component analysis of the obtained database enables to identify four key morphometric descriptors: size, steepness, plan shape and truncation. Hierarchical cluster analysis of these descriptors results in 12 end-member shield types, with intermediate cases defining a continuum of morphologies. The shield types can be linked in terms of growth stages and shape evolution, related to (1) magma composition and rheology, effusion rate and lava/pyroclast ratio, which will condition edifice steepness; (2) spatial distribution of vents, in turn related to the magmatic feeding system and the tectonic framework, which will control edifice plan shape; and (3) caldera formation, which will condition edifice truncation.
PWR upper/lower internals shield
Energy Technology Data Exchange (ETDEWEB)
Homyk, W.A. [Indian Point Station, Buchanan, NY (United States)
1995-03-01
During refueling of a nuclear power plant, the reactor upper internals must be removed from the reactor vessel to permit transfer of the fuel. The upper internals are stored in the flooded reactor cavity. Refueling personnel working in containment at a number of nuclear stations typically receive radiation exposure from a portion of the highly contaminated upper intervals package which extends above the normal water level of the refueling pool. This same issue exists with reactor lower internals withdrawn for inservice inspection activities. One solution to this problem is to provide adequate shielding of the unimmersed portion. The use of lead sheets or blankets for shielding of the protruding components would be time consuming and require more effort for installation since the shielding mass would need to be transported to a support structure over the refueling pool. A preferable approach is to use the existing shielding mass of the refueling pool water. A method of shielding was devised which would use a vacuum pump to draw refueling pool water into an inverted canister suspended over the upper internals to provide shielding from the normally exposed components. During the Spring 1993 refueling of Indian Point 2 (IP2), a prototype shield device was demonstrated. This shield consists of a cylindrical tank open at the bottom that is suspended over the refueling pool with I-beams. The lower lip of the tank is two feet below normal pool level. After installation, the air width of the natural shielding provided by the existing pool water. This paper describes the design, development, testing and demonstration of the prototype device.
A Wavelet-Based Finite Element Method for the Self-Shielding Issue in Neutron Transport
International Nuclear Information System (INIS)
Le Tellier, R.; Fournier, D.; Ruggieri, J. M.
2009-01-01
This paper describes a new approach for treating the energy variable of the neutron transport equation in the resolved resonance energy range. The aim is to avoid recourse to a case-specific spatially dependent self-shielding calculation when considering a broad group structure. This method consists of a discontinuous Galerkin discretization of the energy using wavelet-based elements. A Σ t -orthogonalization of the element basis is presented in order to make the approach tractable for spatially dependent problems. First numerical tests of this method are carried out in a limited framework under the Livolant-Jeanpierre hypotheses in an infinite homogeneous medium. They are mainly focused on the way to construct the wavelet-based element basis. Indeed, the prior selection of these wavelet functions by a thresholding strategy applied to the discrete wavelet transform of a given quantity is a key issue for the convergence rate of the method. The Canuto thresholding approach applied to an approximate flux is found to yield a nearly optimal convergence in many cases. In these tests, the capability of such a finite element discretization to represent the flux depression in a resonant region is demonstrated; a relative accuracy of 10 -3 on the flux (in L 2 -norm) is reached with less than 100 wavelet coefficients per group. (authors)
In-beam background suppression shield
DEFF Research Database (Denmark)
Santoro, V.; Cai, Xiao Xiao; DiJulio, D. D.
2015-01-01
The long (3 ms) proton pulse of the European Spallation Source (ESS) gives rise to unique and potentially high backgrounds for the instrument suite. In such a source an instrument's capabilities will be limited by its Signal to Noise (S/N) ratio. The instruments with a direct view of the moderator......, which do not use a bender to help mitigate the fast neutron background, are the most challenging. For these beam lines we propose the innovative shielding of placing blocks of material directly into the guide system, which allow a minimum attenuation of the cold and thermal fluxes relative...... to the background suppression. This shielding configuration has been worked into a beam line model using Geant4. We study particularly the advantages of single crystal sapphire and silicon blocks....
An assessment of the lifetime of Faraday shield elements
International Nuclear Information System (INIS)
Caughman, J.B.O. II; Ruzic, D.N.; Hoffman, D.J.; Langley, R.A.; Lewis, M.B.; Ryan, P.M.
1989-01-01
The interaction of plasma with rf fields from an ion cyclotron range of frequencies (ICRF) antenna has been studied to estimate the amount of Faraday shield erosion expected in normal ICRF heating (ICRH) operation. Plasma parameters and ion energies have been measured in the near field of an antenna and used in a model to estimate the erosion rate of the Faraday shield surface. Experiments were conducted on the RF Test Facility (RFTF), a magnetic mirror device at Oak Ridge National Laboratory (ORNL), using a single-strap resonant loop antenna with a two-tier Faraday shield. The outer tier, facing the plasma, was layered with graphite tiles. The antenna was operated at currents and voltages (∼500 A, ∼20 kV at 25 kW) within 50% of those expected in tokamaks. The time varying floating potential was measured with a capacitively coupled probe, and the time-averaged floating potential, electron temperature, and electron density were measured with a Langmuir probe. Both probes were scanned in front of the antenna. Ion energies were measured with a gridded energy analyzer located below the antenna, and samples of silicon were placed on the Faraday shield surface to estimate the incident ion energy. The capacitive probe measurements show that the rf floating potential follows the magnetic field pattern of the antenna, indicating that the electromagnetic fields are responsible for the potential formation. Plasma parameters and ion energies have been correlated with the antenna current and used in s computational model of the plasma sheath to predict the amount of erosion expected from the Faraday shield elements exposed to plasma. Predictions of light ion sputtering of candidate Faraday shield materials are presented. 19 refs., 6 figs., 1 tab
International Nuclear Information System (INIS)
Zhang, Tianli; Li, Zhuoxin; Kou, Sindo; Jing, Hongyang; Li, Guodong; Li, Hong; Jin Kim, Hee
2015-01-01
The effect of inclusions on the microstructure and toughness of the deposited metals of self-shielded flux cored wires was investigated by optical microscopy, electron microscopy and mechanical testing. The deposited metals of three different wires showed different levels of low temperature impact toughness at −40 °C mainly because of differences in the properties of inclusions. The inclusions formed in the deposited metals as a result of deoxidation caused by the addition of extra Al–Mg alloy and ferromanganese to the flux. The inclusions, spherical in shape, were mixtures of Al 2 O 3 and MgO. Inclusions predominantly Al 2 O 3 and 0.3–0.8 μm in diameter were effective for nucleation of acicular ferrite. However, inclusions predominantly MgO were promoted by increasing Mg in the flux and were more effective than Al 2 O 3 inclusions of the same size. These findings suggest that the control of inclusions can be an effective way to improve the impact toughness of the deposited metal
Shielding experiments for accelerator facilities
Energy Technology Data Exchange (ETDEWEB)
Nakashima, Hiroshi; Tanaka, Susumu; Sakamoto, Yukio [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment] [and others
2000-06-01
A series of shielding experiments was carried out by using AVF cyclotron accelerator of TIARA at JAERI in order to validate shielding design methods for accelerator facilities in intermediate energy region. In this paper neutron transmission experiment through thick shields and radiation streaming experiment through a labyrinth are reported. (author)
Shielding experiments for accelerator facilities
International Nuclear Information System (INIS)
Nakashima, Hiroshi; Tanaka, Susumu; Sakamoto, Yukio
2000-01-01
A series of shielding experiments was carried out by using AVF cyclotron accelerator of TIARA at JAERI in order to validate shielding design methods for accelerator facilities in intermediate energy region. In this paper neutron transmission experiment through thick shields and radiation streaming experiment through a labyrinth are reported. (author)
Nuclear data for radiation shielding
International Nuclear Information System (INIS)
Miyasaka, Shunichi; Takahashi, Hiroshi.
1976-01-01
The third shielding expert conference was convened in Paris in Oct. 1975 for exchanging informations about the sensitivity evaluation of nuclear data in shielding calculation and integral bench mark experiment. The requirements about nuclear data presented at present from the field of nuclear design do not reflect sufficiently the requirements of shielding design, therefore it was the object to gather the requirements about nuclear data from the field of shielding. The nuclides used for shielding are numerous, and the nuclear data on these isotopes are required. Some of them cannot be ignored as the source of secondary γ-ray or in view of the radioactivation of materials. The requirements for the nuclear data of neutrons in the field of shielding are those concerning the reaction cross sections producing secondary γ-ray, the reaction cross sections including the production of secondary neutrons, elastic scattering cross sections, and total cross sections. The topics in the Paris conference about neutron shielding data are described, such as the methodology of sensitivity evaluation, the standardization of group constant libraries, the bench mark experiment on iron and sodium, and the cross section of γ-ray production. In the shielding of nuclear fission reactors, the γ-ray production owing to nuclear fission reaction is also important. In (d, t) fusion reactors, high energy neutrons are generated, and high energy γ-ray is emitted through giant E1 resonance. (Kako, I.)
Optimization of multi-layered metallic shield
International Nuclear Information System (INIS)
Ben-Dor, G.; Dubinsky, A.; Elperin, T.
2011-01-01
Research highlights: → We investigated the problem of optimization of a multi-layered metallic shield. → The maximum ballistic limit velocity is a criterion of optimization. → The sequence of materials and the thicknesses of layers in the shield are varied. → The general problem is reduced to the problem of Geometric Programming. → Analytical solutions are obtained for two- and three-layered shields. - Abstract: We investigate the problem of optimization of multi-layered metallic shield whereby the goal is to determine the sequence of materials and the thicknesses of the layers that provide the maximum ballistic limit velocity of the shield. Optimization is performed under the following constraints: fixed areal density of the shield, the upper bound on the total thickness of the shield and the bounds on the thicknesses of the plates manufactured from every material. The problem is reduced to the problem of Geometric Programming which can be solved numerically using known methods. For the most interesting in practice cases of two-layered and three-layered shields the solution is obtained in the explicit analytical form.
Energy Technology Data Exchange (ETDEWEB)
Santos, Romulo R.; Real, Jessica V.; Luz, Renata M. da [Hospital Sao Lucas (PUCRS), Porto Alegre, RS (Brazil); Friedrich, Barbara Q.; Silva, Ana Maria Marques da, E-mail: ana.marques@pucrs.br [Pontificia Universidade Catolica do Rio Grande do Sul (PUCRS), Porto Alegre, RS (Brazil)
2013-08-15
In shielding calculation of radiological facilities, several parameters are required, such as occupancy, use factor, number of patients, source-barrier distance, area type (controlled and uncontrolled), radiation (primary or secondary) and material used in the barrier. The shielding design optimization requires a review of several options about the physical facility design and, mainly, the achievement of the best cost-benefit relationship for the shielding material. To facilitate the development of this kind of design, a program to calculate the shielding in diagnostic radiology was implemented, based on data and limits established by National Council on Radiation Protection and Measurements (NCRP) 147 and SVS-MS 453/98. The program was developed in C⌗ language, and presents a graphical interface for user data input and reporting capabilities. The module initially implemented, called SHIELD 1.0, refers to calculating barriers for conventional X-ray rooms. The program validation was performed by the comparison with the results of examples of shielding calculations presented in NCRP 147.
Determining women's sexual self-schemas through advanced computerized text analysis.
Stanton, Amelia M; Boyd, Ryan L; Pulverman, Carey S; Meston, Cindy M
2015-08-01
The meaning extraction method (MEM), an advanced computerized text analysis technique, was used to analyze women's sexual self-schemas. Participants (n=239) completed open-ended essays about their personal feelings associated with sex and sexuality. These essays were analyzed using the MEM, a procedure designed to extract common themes from natural language. Using the MEM procedure, we extracted seven unique themes germane to sexual self-schemas: family and development, virginity, abuse, relationship, sexual activity, attraction, and existentialism. Each of these themes is comprised of frequently used words across the participants' descriptions of their sexual selves. Significant differences in sexual self-schemas were observed to covary with age, relationship status, and sexual abuse history. Copyright © 2015 Elsevier Ltd. All rights reserved.
SHIELD verification and validation report
International Nuclear Information System (INIS)
Boman, C.
1992-02-01
This document outlines the verification and validation effort for the SHIELD, SHLDED, GEDIT, GENPRT, FIPROD, FPCALC, and PROCES modules of the SHIELD system code. Along with its predecessors, SHIELD has been in use at the Savannah River Site (SRS) for more than ten years. During this time the code has been extensively tested and a variety of validation documents have been issued. The primary function of this report is to specify the features and capabilities for which SHIELD is to be considered validated, and to reference the documents that establish the validation
Radiation shield for nuclear reactors
International Nuclear Information System (INIS)
Weissenfluh, J.A.
1978-01-01
A shield for use with nuclear reactor systems to attenuate radiation resulting from reactor operation is described. The shield comprises a container preferably of a thin, flexible or elastic material, which may be in the form of a bag, a mattress, a toroidal segment or toroid or the like filled with radiation attenuating liuid. Means are provided in the container for filling and draining the container in place. Due to its flexibility, the shield readily conforms to irregularities in surfaces with which it may be in contact in a shielding position
Experimental verification of photon: A program for use in x-ray shielding calculations
International Nuclear Information System (INIS)
Brauer, E.; Thomlinson, W.
1987-01-01
At the National Synchrotron Light Source, a computer program named PHOTON has been developed to calculate radiation dose values around a beam line. The output from the program must be an accurate guide to beam line shielding. To test the program, a series of measurements of radiation dose were carried out using existing beam lines; the results were compared to the theoretical calculations of PHOTON. Several different scattering geometries, scattering materials, and sets of walls and shielding materials were studied. Results of the measurements allowed many advances to be made in the program, ultimately resulting in good agreement between the theory and experiment. 3 refs., 6 figs
Hybrid Active-Passive Radiation Shielding System
National Aeronautics and Space Administration — A radiation shielding system is proposed that integrates active magnetic fields with passive shielding materials. The objective is to increase the shielding...
Magnetic shielding of an inhomogeneous magnetic field source by a bulk superconducting tube
International Nuclear Information System (INIS)
Hogan, K; Fagnard, J-F; Wéra, L; Vanderheyden, B; Vanderbemden, P
2015-01-01
Bulk type-II irreversible superconductors can act as excellent passive magnetic shields, with a strong attenuation of low frequency magnetic fields. Up to now, the performances of superconducting magnetic shields have mainly been studied in a homogenous magnetic field, considering only immunity problems, i.e. when the field is applied outside the tube and the inner field should ideally be zero. In this paper, we aim to investigate experimentally and numerically the magnetic response of a high-T c bulk superconducting hollow cylinder at 77 K in an emission problem, i.e. when subjected to the non-uniform magnetic field generated by a source coil placed inside the tube. A bespoke 3D mapping system coupled with a three-axis Hall probe is used to measure the magnetic flux density distribution outside the superconducting magnetic shield. A finite element model is developed to understand how the magnetic field penetrates into the superconductor and how the induced superconducting shielding currents flow inside the shield in the case where the emitting coil is placed coaxially inside the tube. The finite element modelling is found to be in excellent agreement with the experimental data. Results show that a concentration of the magnetic flux lines occurs between the emitting coil and the superconducting screen. This effect is observed both with the modelling and the experiment. In the case of a long tube, we show that the main features of the field penetration in the superconducting walls can be reproduced with a simple analytical 1D model. This model is used to estimate the maximum flux density of the emitting coil that can be shielded by the superconductor. (paper)
A Shielding Analysis of Hot Cell for a 10 MW Research Reactor
International Nuclear Information System (INIS)
Alnajjar, Alaaddin; Park, Chang Je; Roh, Gyuhong; Lee, Byunchul
2013-01-01
In this paper, a shielding analysis has been performed for the hot cell in a 10 MW research reactor. Two kinds of shielding analysis code systems are used such as MCNPX2.7 and M-Shield7. The first one is Monte Carlo stochastic code and the second one is a deterministic point kernel code. The results are compared in this study. In order to obtain source term, the ORIGEN-S code is used for different kinds of source. Four kinds of sources are taken into consideration. From the simulation, it is also proposed that the proper thickness of shielding material and the maximum source capacity in the hot cell. This study shows preliminary analysis results of hot cell shielding for 10MW research reactor. Total four different source terms are considered such as spent fuel assembly, Ir-192, Mo-99, and I-131. For shielding material, general concrete, heavy concrete, and lead are used. MCNPX code is mainly used for a simplified hot cell model and the result are nearly consistent when compared with M-Shield code. Required shielding thickness and the hot cell capacity are also obtained for various criterion of surface dose rates
Promoting advance directives among African Americans: a faith-based model.
Bullock, Karen
2006-02-01
Studies show that African Americans are less likely than other ethnic groups to complete advance directives. However, what influences African Americans' decisions to complete or not complete advance directives is unclear. Using a faith-based promotion model, 102 African Americans aged 55 years or older were recruited from local churches and community-based agencies to participate in a pilot study to promote advance care planning. Focus groups were used to collect data on participants' preferences for care, desire to make personal choices, values and attitudes, beliefs about death and dying, and advance directives. A standardized interview was used in the focus groups, and the data were organized and analyzed using NUDIST 4 software (QRS Software, Victoria, Australia). Three fourths of the participants refused to complete advance directives. The following factors influenced the participants' decisions about end-of-life care and completion of an advance directive: spirituality; view of suffering, death, and dying; social support networks; barriers to utilization; and mistrust of the health care system. The dissemination of information apprises individuals of their right to self-determine about their care, but educational efforts may not produce a significant change in behavior toward completion of advance care planning. Thus, ongoing efforts are needed to improve the trust that African Americans have in medical and health care providers.
Handout on shielding calculation
International Nuclear Information System (INIS)
Heilbron Filho, P.F.L.
1991-01-01
In order to avoid the difficulties of the radioprotection supervisors in the tasks related to shielding calculations, is presented in this paper the basic concepts of shielding theory. It also includes exercises and examples. (author)
WAPDEG Analysis of Waste Package and Drip shield Degradation
International Nuclear Information System (INIS)
K. Mon
2004-01-01
As directed by ''Technical Work Plan for: Regulatory Integration Modeling and Analysis of the Waste Form and Waste Package'' (BSC 2004 [DIRS 171583]), an analysis of the degradation of the engineered barrier system (EBS) drip shields and waste packages at the Yucca Mountain repository is developed. The purpose of this activity is to provide the TSPA with inputs and methodologies used to evaluate waste package and drip shield degradation as a function of exposure time under exposure conditions anticipated in the repository. This analysis provides information useful to satisfy ''Yucca Mountain Review Plan, Final Report'' (NRC 2003 [DIRS 163274]) requirements. Several features, events, and processes (FEPs) are also discussed (Section 6.2, Table 15). The previous revision of this report was prepared as a model report in accordance with AP-SIII.10Q, Models. Due to changes in the role of this report since the site recommendation, it no longer contains model development. This revision is prepared as a scientific analysis in accordance with AP-SIII.9Q, ''Scientific Analyses'' and uses models previously validated in (1) ''Stress Corrosion Cracking of the Drip Shield, the Waste Package Outer Barrier, and the Stainless Steel Structural Material'' (BSC 2004 [DIRS 169985]); (2) ''General Corrosion and Localized Corrosion of Waste Package Outer Barrier'' (BSC 2004 [DIRS 169984]); and (3) ''General Corrosion and Localized Corrosion of Drip Shield'' (BSC 2004 [DIRS 169845]). The integrated waste package degradation (IWPD) analysis presented in this report treats several implementation-related issues, such as defining the number and size of patches per waste package that undergo stress corrosion cracking; recasting the weld flaw analysis in a form as implemented in the Closure Weld Defects (CWD) software; and, general corrosion rate manipulations (e.g., change of scale in Section 6.3.4). The weld flaw portion of this report takes input from an engineering calculation (BSC 2004
Directory of Open Access Journals (Sweden)
Chuan Hu
Full Text Available In face-to-face communications, to avoid sanctions and disapproval from others, people are more likely to hide negative aspects of their true self (such as socially undesirable personalities, minds, beliefs and consciousness to avoid conflict with social norms and laws. The anonymity of cyberspace provides people a unique environment to behave more freely and openly with less restraint from the real word. Existing research related to online true self expression has mainly explored true self as an independent aspect of self. Regarding true self as a two-dimensional concept, this study investigates true self from the perspective of individuals' self-guide and identity reconstruction in both online and offline world. Using qualitative research methods, the current study investigates 57 participants through interviews and questionnaires. Content analysis reveals four factors that motivate people to express more true self (especially negative true self when reconstructing their online identity and involve true self as a part of their self-guide in anonymous environment. By incorporating true self as an important part of individuals' self-guide and identity online, the current study advances self-discrepancy theory, making it more comprehensive for cyberspace. The results are also interpreted based on self-determination theory. The theoretical contributions of this study are discussed and practical implications are also presented.
Pretinning Nickel-Plated Wire Shields
Igawa, J. A.
1985-01-01
Nickel-plated copper shielding for wires pretinned for subsequent soldering with help of activated rosin flux. Shield cut at point 0.25 to 0.375 in. (6 to 10 mm) from cut end of outer jacket. Loosened end of shield straightened and pulled toward cut end. Insulation of inner wires kept intact during pretinning.
Radiation Shielding Materials and Containers Incorporating Same
Energy Technology Data Exchange (ETDEWEB)
Mirsky, Steven M.; Krill, Stephen J.; and Murray, Alexander P.
2005-11-01
An improved radiation shielding material and storage systems for radioactive materials incorporating the same. The PYRolytic Uranium Compound (''PYRUC'') shielding material is preferably formed by heat and/or pressure treatment of a precursor material comprising microspheres of a uranium compound, such as uranium dioxide or uranium carbide, and a suitable binder. The PYRUC shielding material provides improved radiation shielding, thermal characteristic, cost and ease of use in comparison with other shielding materials. The shielding material can be used to form containment systems, container vessels, shielding structures, and containment storage areas, all of which can be used to house radioactive waste. The preferred shielding system is in the form of a container for storage, transportation, and disposal of radioactive waste. In addition, improved methods for preparing uranium dioxide and uranium carbide microspheres for use in the radiation shielding materials are also provided.
SHIELDING OF A UNIFORM ALTERNATING MAGNETIC FIELD USING A CIRCULAR PASSIVE LOOP
Directory of Open Access Journals (Sweden)
V. S. Grinchenko
2015-04-01
Full Text Available The magnetic and electromagnetic shields are used to reduce the magnetic field in local spaces. Usually these shields are implemented in the form of a box or a cylinder. At the same time the magnetic field reduction in local spaces by means of passive loops is not considered in detail yet. So, the present study considers shielding capabilities of a circular passive loop. The authors have performed an analytical and numerical modeling of a process of a uniform harmonic magnetic field shielding. The simulated results permit to find out the spatial distribution of the shielded magnetic field. Dependencies of shielding effectiveness on the passive loop radius and cross-section are determined. Moreover, the non-monotonic behavior of the loop radius dependence is shown. We have substantiated that the shielded volume of a circular passive loop is advisable to limit by the sphere with a half loop radius. Presented results give parameters of the circular passive loop that reduces the rms value of the magnetic flux density by 30 %.
Measuring space radiation shielding effectiveness
Directory of Open Access Journals (Sweden)
Bahadori Amir
2017-01-01
Full Text Available Passive radiation shielding is one strategy to mitigate the problem of space radiation exposure. While space vehicles are constructed largely of aluminum, polyethylene has been demonstrated to have superior shielding characteristics for both galactic cosmic rays and solar particle events due to the high hydrogen content. A method to calculate the shielding effectiveness of a material relative to reference material from Bragg peak measurements performed using energetic heavy charged particles is described. Using accelerated alpha particles at the National Aeronautics and Space Administration Space Radiation Laboratory at Brookhaven National Laboratory, the method is applied to sample tiles from the Heat Melt Compactor, which were created by melting material from a simulated astronaut waste stream, consisting of materials such as trash and unconsumed food. The shielding effectiveness calculated from measurements of the Heat Melt Compactor sample tiles is about 10% less than the shielding effectiveness of polyethylene. Shielding material produced from the astronaut waste stream in the form of Heat Melt Compactor tiles is therefore found to be an attractive solution for protection against space radiation.
Measuring space radiation shielding effectiveness
Bahadori, Amir; Semones, Edward; Ewert, Michael; Broyan, James; Walker, Steven
2017-09-01
Passive radiation shielding is one strategy to mitigate the problem of space radiation exposure. While space vehicles are constructed largely of aluminum, polyethylene has been demonstrated to have superior shielding characteristics for both galactic cosmic rays and solar particle events due to the high hydrogen content. A method to calculate the shielding effectiveness of a material relative to reference material from Bragg peak measurements performed using energetic heavy charged particles is described. Using accelerated alpha particles at the National Aeronautics and Space Administration Space Radiation Laboratory at Brookhaven National Laboratory, the method is applied to sample tiles from the Heat Melt Compactor, which were created by melting material from a simulated astronaut waste stream, consisting of materials such as trash and unconsumed food. The shielding effectiveness calculated from measurements of the Heat Melt Compactor sample tiles is about 10% less than the shielding effectiveness of polyethylene. Shielding material produced from the astronaut waste stream in the form of Heat Melt Compactor tiles is therefore found to be an attractive solution for protection against space radiation.
Explaining the “how” of self-esteem development : The self-organizing self-esteem model
de Ruiter, Naomi M.P.; van Geert, Paul L.C.; Kunnen, E. Saskia
2017-01-01
The current article proposes a theoretical model of self-esteem called the Self-Organizing Self-Esteem (SOSE) model. The model provides an integrative framework for conceptualizing and understanding the intrinsic dynamics of self-esteem and the role of the context across 3 levels of development: The
Topographic evidence for shield volcanism on Io
International Nuclear Information System (INIS)
Moore, J.M.; Mcewen, A.S.; Albin, E.F.; Greeley, R.
1986-01-01
Similarities between terrestrial shield volcanoes and a volcano on Io observed in Voyager I imagery of the satellite at 30 0 S, 246 0 W are delineated. A photoclinometry model was used to numerically estimate the slope based on the Minnaert photometric function. The slope values are accurate to within 10 deg on the sun-facing slope and 1 deg on the shadow side. As found with shield volcanoes, the feature has a central edifice, 40-50 km in diameter, and a broad, elliptical base, 77 x 90 km across. The summit of the Io volcano is 2.2-2.8 km above the surrounding plane and contains a caldera about 5 km in diameter. The similarity in shape between basaltic terrestrial shield volcanoes and the Io volcano indicates that the Io feature may also be composed of basalt. The composition could be sulfur if the heat flow was under 0.05 W/sq m, as it might have been in later stages of formation. 9 references
Groundwater flow system stability in shield settings a multi-disciplinary approach
International Nuclear Information System (INIS)
Jensen, M.R.; Goodwin, B.W.
2004-01-01
Within the Deep Geologic Repository Technology Program (DGRTP) several Geoscience activities are focused on advancing the understanding of groundwater flow system evolution and geochemical stability in a Shield setting as affected by long-term climate change. A key aspect is developing confidence in predictions of groundwater flow patterns and residence times as they relate to the safety of a Deep Geologic Repository for used nuclear fuel waste. A specific focus in this regard has been placed on constraining redox stability and groundwater flow system dynamics during the Pleistocene. Attempts are being made to achieve this through a coordinated multi-disciplinary approach intent on; i) demonstrating coincidence between independent geo-scientific data; ii) improving the traceability of geo-scientific data and its interpretation within a conceptual descriptive model(s); iii) improving upon methods to assess and demonstrate robustness in flow domain prediction(s) given inherent flow domain uncertainties (i.e. spatial chemical/physical property distributions; boundary conditions) in time and space; and iv) improving awareness amongst geo-scientists as to the utility various geo-scientific data in supporting a repository safety case. Coordinated by the DGRTP, elements of this program include the development of a climate driven Laurentide ice-sheet model to constrain the understanding of time rate of change in boundary conditions most affecting the groundwater flow domain and its evolution. Further work has involved supporting WRA Paleo-hydrogeologic studies in which constrained thermodynamic analyses coupled with field studies to characterize the paragenesis of fracture infill mineralogy are providing evidence to premise understandings of possible depth of penetration by oxygenated glacial recharge. In parallel. numerical simulations have been undertaken to illustrate aspect of groundwater flow system stability and evolution in a Shield setting. Such simulations
Shielding technology for high energy radiation production facility
International Nuclear Information System (INIS)
Lee, Byung Chul; Kim, Heon Il
2004-06-01
In order to develop shielding technology for high energy radiation production facility, references and data for high energy neutron shielding are searched and collected, and calculations to obtain the characteristics of neutron shield materials are performed. For the evaluation of characteristics of neutron shield material, it is chosen not only general shield materials such as concrete, polyethylene, etc., but also KAERI developed neutron shields of High Density PolyEthylene (HDPE) mixed with boron compound (B 2 O 3 , H 2 BO 3 , Borax). Neutron attenuation coefficients for these materials are obtained for later use in shielding design. The effect of source shape and source angular distribution on the shielding characteristics for several shield materials is examined. This effect can contribute to create shielding concept in case of no detail source information. It is also evaluated the effect of the arrangement of shield materials using current shield materials. With these results, conceptual shielding design for PET cyclotron is performed. The shielding composite using HDPE and concrete is selected to meet the target dose rate outside the composite, and the dose evaluation is performed by configuring the facility room conceptually. From the result, the proper shield configuration for this PET cyclotron is proposed
Royal, Kevin; Crawford, Christopher; Mullins, Andrew; Porter, Greg; Blanton, Hunter; Johnstone, Connor; Kistler, Ben; Olivera, Daniela
2017-09-01
The search for the electric dipole moment of the neutron requires the ambient magnetic field to be on the pT scale which is accomplished with large magnetic shielding rooms. These rooms are fitted with large mu-metal sheets to allow for passive cancellation of background magnetic fields. Active shielding technology cannot uniformly cancel background magnetic fields. These issues can be remedied by combining the methods into a hybrid system. The design used is composed of panels that have an active layer of cancellation between two sheets of mu-metal. The panels form a cube and draw in magnetic fields perpendicular to the surface which can then be reduced using active shielding. This work is supported by the Department of Energy under Contract DE-SC0008107.
Modular reactor head shielding system
International Nuclear Information System (INIS)
Jacobson, E. B.
1985-01-01
An improved modular reactor head shielding system is provided that includes a frame which is removably assembled on a reactor head such that no structural or mechanical alteration of the head is required. The shielding system also includes hanging assemblies to mount flexible shielding pads on trolleys which can be moved along the frame. The assemblies allow individual pivoting movement of the pads. The pivoting movement along with the movement allowed by the trolleys provides ease of access to any point on the reactor head. The assemblies also facilitate safe and efficient mounting of the pads directly to and from storage containers such that workers have additional shielding throughout virtually the entire installation and removal process. The flexible shielding pads are designed to interleave with one another when assembled around the reactor head for substantially improved containment of radiation leakage
International Nuclear Information System (INIS)
Higgy, H.R.; Abdel-Rassoul, A.A.
1983-01-01
A plan to erect a mechanical shielded hot cell in the process hall of the Radiochemical Laboratory at Inchas is described. The hot cell is designed for safe handling of spent fuel bundles, from the Inchas reactor, and for dismantling and cutting the fuel rods in preparation for subsequent treatment. The biological shielding allows for the safe handling of a total radioactivity level up to 10,000 MeV-Ci. The hot cell consists of an α-tight stainless-steel box, connected to a γ-shielded SAS, through an air-lock containing a movable carriage. The α-box is tightly connected with six dry-storage cavities for adequate storage of the spent fuel bundles. Both the α-box, with the dry-storage cavities, and the SAS are surrounded by 200-mm thick biological lead shielding. The α-box is equipped with two master-slave manipulators, a lead-glass window, a monorail crane and Padirac and Minirag systems. The SAS is equipped with a lead-glass window, tong manipulator, a shielded pit and a mechanism for the entry of the spent fuel bundle. The hot cell is served by adequate ventilation and monitoring systems. (author)
International Nuclear Information System (INIS)
Aitken, D.
1979-01-01
Shields for equipment in which ionising radiation is associated with high electrical gradients, for example X-ray tubes and particle accelerators, incorporate a radiation-absorbing metal, as such or as a compound, and are electrically non-conducting and can be placed in the high electrical gradient region of the equipment. Substances disclosed include dispersions of lead, tungsten, uranium or oxides of these in acrylics polyesters, PVC, ABS, polyamides, PTFE, epoxy resins, glass or ceramics. The material used may constitute an evacuable enclosure of the equipment or may be an external shield thereof. (U.K.)
Geophysical and geochemical models of the Earth's shields and rift zones
International Nuclear Information System (INIS)
Chung, D.H.
1977-01-01
This report summarizes a collection of, synthesis of, and speculation on the geophysical and geochemical models of the earth's stable shields and rift zones. Two basic crustal types, continental and oceanic, and two basic mantle types, stable and unstable, are described. It is pointed out that both the crust and upper mantle play a strongly interactive role with surface geological phenomena ranging from the occurrence of mountains, ocean trenches, oceanic and continental rifts to geographic distributions of earthquakes, faults, and volcanoes. On the composition of the mantle, there is little doubt regarding the view that olivine constitutes a major fraction of the mineralogy of the earth's upper mantle. Studies are suggested to simulate the elasticity and composition of the earth's lower crust and upper mantle
International Nuclear Information System (INIS)
Ijiri, Yasuo; Fujinuma, Tadashi; Tamura, Shoji.
1989-01-01
Radiation shielding cloth having radiation shielding layers comprising a composition of inorganic powder of high specific gravity and rubber are excellentin flexibility and comfortable to put on. However, since they are heavy in the weight, operators are tired upon putting them for a long time. In view of the above, the radiation ray shielding layers are prepared by calendering sheets obtained by preliminary molding of the composition to set the variation of the thickness within a range of +15% to -0% of prescribed thickness. Since the composition of inorganic powder at high specific gravity and rubber used for radiation ray shielding comprises a great amount of inorganic powder at high specific gravity blended therein, it is generally poor in fabricability. Therefor, it is difficult to attain fine control for the sheet thickness by merely molding a composition block at once. Then, the composition is at first preliminarily molded into a sheet-like shape which is somewhat thickener than the final thickness and then finished by calendering, by which the thickness can be reduced in average as compared with conventional products while keeping the prescribed thickness and reducing the weight reduce by so much. (N.H.)
International Nuclear Information System (INIS)
Kido, Kazuhiro; Ueda, Hajime.
1997-01-01
It was found that a glass composition comprising, as essential ingredients, SiO 2 , PbO, Gd 2 O 3 and alkali metal oxides can provide a shielding performance against electromagnetic waves, charged particles and neutrons. The present invention provides radiation shielding glass containing at least from 16 to 46wt% of SiO 2 , from 47 to 75wt% of PbO, from 1 to 10wt% of Gd 2 O 3 , from 0 to 3wt% of Li 2 O, from 0 to 7wt% of Na 2 O, from 0 to 7wt% of K 2 O provided that Li 2 O + Na 2 O + K 2 O is from 1 to 10wt%, B 2 O 3 is from 0 to 10wt%, CeO 2 is from 0 to 3wt%, As 2 O 3 is from 0 to 1wt% and Sb 2 O 3 is from 0 to 1wt%. Since the glass can shield electromagnetic waves, charged particles and neutrons simultaneously, radiation shielding windows can be designed and manufactured at a reduced thickness and by less constitutional numbers in a circumstance where they are present altogether. (T.M.)
Buggey, Tom; Ogle, Lindsey
2012-01-01
Video self-modeling (VSM) first appeared on the psychology and education stage in the early 1970s. The practical applications of VSM were limited by lack of access to tools for editing video, which is necessary for almost all self-modeling videos. Thus, VSM remained in the research domain until the advent of camcorders and VCR/DVD players and,…
Shielding modification design of the N.S. Mutsu
International Nuclear Information System (INIS)
Yamaji, A.; Miyakoshi, J.; Kageyama, T.; Futamura, Y.
1983-01-01
Shielding modification design of the N.S. Mutsu was performed for reducing the radiation doses outside the primary and the secondary shields by providing shields for neutrons streaming through the air gap between the pressure vessel and the primary shield. This was accomplished by replacing parts of the shields and adding new shields in the upper and lower sections of both primary and secondary shields, and also replacing the thermal insulator in the gap. The shielding design calculations were made using one- and two-dimensional discrete ordinates codes and also a point kernel code. Special attention was paid to the calculations of, (1) the neutrons streaming through the gap between the pressure vessel and the primary shield, (2) the radiations transmitted through the radial shield of the core in the primary shield, (3) the radiations transmitted through the upper and lower sections of the secondary shield, and (4) the dose rate equivalent in the accommodation area. Their calculational accuracies were estimated by analyzing various experiments. To support the modification, a variety of experiments and tests were carried out, which were material tests, cooling test of the primary shield, mechanical strength test of the double bottom, trial fabrication tests of new shields, performance degradation test of heavy concrete and duct streaming experiment in the secondary shield. (author)
Neutron shielding and its impact on the ITER machine design
International Nuclear Information System (INIS)
Daenner, W.; El Guebaly, L.; Sawan, M.; Gohar, Y.; Maki, K.; Rado, V.; Schchipakin, O.; Zimin, S.
1991-01-01
This paper describes the efforts made in the frame of the ITER project to analyze the shielding of the superconducting magnets. First, the radiation limits to be achieved are specified as well as the neutron source in terms of wall loading on the first wall of the machine. Then the general shield concept is explained, including the most essential details of the various shield components. A brief section is devoted to the calculational tools, the data base, and the safety factors to be applied to the results obtained. The neutronics models of four different configurations are summarized as they were used to study the most critical parts of the machine. This section is followed by a presentation of the most important results from one-, two- and three-dimensional calculations. They are given for both the reference design and an improved one in which the critical regions are reinforced with respect to their shielding capability. It is concluded that the ITER shield layout just marginally meets the stated limits provided that some tungsten is included in the critical regions. A slight revision of the overall machine dimensions with the aim to achieve a less complex shield and a higher margin with respect to the limits is, however, seen the better solution. (orig.)
Comparison of eye shields in radiotherapeutic beams
International Nuclear Information System (INIS)
Currie, B.E.; Wellington Hospital, Wellington; Johnson, A.D.
2004-01-01
Full text: Both MeV electrons and kV photons are used in the treatment of superficial cancers. The advantages and disadvantages for each of these modalities have been widely reported in the literature (See for example [1-2]). Of particular note in the literature is the use of lead and tungsten eye shields to protect ocular structures during radiotherapy. An investigation addressing issues raised in the literature that are relevant to the Wellington Cancer Centre method of treatment of lesions near the eye shall be summarised. Various small sized fields were irradiated to determine depth dose and profile curves in a water phantom shielded by various commercially available eye shields. Transmission factors relevant to critical ocular structures and particle distribution theories are used to further elucidate the comparison between the use of MeV electrons and kV photons in the treatment of superficial cancers. Superficial X-rays from a Pantak Therapax unit SXT 150 model of HVL 4.90mm Al were used for the lead eye shield measurements and electrons from a Varian Clinac 2100C nominal energies 6MeV and 9MeV (R p 3.00cm and 4.34cm respectively) were used for the tungsten eye shield measurements. For the photon measurements circular applicators of 3cm, 4cm and 5cm diameter were used and for the electrons standard 6x6cm and 10x 10cm applicators were used, with no custom inserts. A Scanditronix RFA-300 water phantom and Scanditronix RFAplus version 5.3 software application were used to collect and collate all data. The eye shields were the Radiation Products Design Inc. medium lead eye shield (item 934-014) and the MED-TEC tungsten eye shields MT-T-45 M and MT-T-45 S. It is demonstrated that electron fields have appreciably greater scatter into the area directly under the eye shields than the photon fields. Similarly at the region of d max for the electron fields the relative dose is appreciably greater than the photon fields at similar depth. The relative merits for
Gamma ray absorption of cylindrical fissile material with dual shields
International Nuclear Information System (INIS)
Wu Chenyan; Cheng Yiying; Huang Yongyi; Lu Fuquan; Yang Fujia
2005-01-01
This work analyzed the gamma ray attenuation effect from the self-absorption and shield attenuation perspectively. An exact mathematical equation was given for the geometric factor of the cylindrical fissile material with dual shields. In addition, several approximation approaches suitable for real situation were discussed, especially in the radial and axial directions of the cylinders, since the G-factors have simple forms. Then the space distribution patterns of the G-factor were analyzed based on numerical result and effective ways to solved the geometric information of the cylindrical fissile material, the radii and the heights, were deduced. This method was checked and verified by numerical calculation. Because of the efficiency of the method, it is ideal for application in real situations, such as nuclear safeguards, which demands speed of detection and accuracy of geometric analysis. (authors)
International Nuclear Information System (INIS)
Winkler, N.T.
1976-01-01
A radiation shield is described in the form of a stranded curtain made up of bead-chains whose material and geometry are selected to produce a cross-sectional density that is the equivalent of 0.25 mm or more of lead and which curtain may be mounted on various radiological devices to shield against scattered radiation while offering a minimum of obstruction to the radiologist
International Nuclear Information System (INIS)
Meuschke, R.E.; Boyd, C.H.
1989-01-01
This patent describes a method of limiting the movement of a thermal shield of a nuclear reactor. It comprises: machining at least four (4) pockets in upper portions of a thermal shield circumferentially about a core barrel of a nuclear reactor to receive key-wave inserts; tapping bolt holes in the pockets of the thermal shield to receive bolts; positioning key-wave inserts into the pockets of the thermal shield to be bolted in place with the bolt holes; machining dowel holes at least partially through the positioned key-way inserts and the thermal shield to receive dowel pins; positioning dowel pins in the dowel holes in the key-way insert and thermal shield to tangentially restrain movement of the thermal shield relative to the core barrel; sliding limiter keys into the key-way inserts and bolting the limiter keys to the core barrel to tangentially restrain movement of the thermal shield relative and the core barrel while allowing radial and axial movement of the thermal shield relative to the core barrel; machining dowel holes through the limiter key and at least partially through the core barrel to receive dowel pins; positioning dowel pins in the dowel holes in the limiter key and core barrel to restrain tangential movement of the thermal shield relative to the core barrel of the nuclear reactor
Welding shield for coupling heaters
Menotti, James Louis
2010-03-09
Systems for coupling end portions of two elongated heater portions and methods of using such systems to treat a subsurface formation are described herein. A system may include a holding system configured to hold end portions of the two elongated heater portions so that the end portions are abutted together or located near each other; a shield for enclosing the end portions, and one or more inert gas inlets configured to provide at least one inert gas to flush the system with inert gas during welding of the end portions. The shield may be configured to inhibit oxidation during welding that joins the end portions together. The shield may include a hinged door that, when closed, is configured to at least partially isolate the interior of the shield from the atmosphere. The hinged door, when open, is configured to allow access to the interior of the shield.
Shield calculations, optimization vs. paradigm
International Nuclear Information System (INIS)
Cornejo D, N.; Hernandez S, A.; Martinez G, A.
2006-01-01
Many shieldings have been designed under the criteria of 'Maximum dose rates of project'. It has created the paradigm of those 'low dose rates', for the one which not few specialists would consider unacceptable levels of dose rate superior to the units of μSv.h -1 , independently of the exposure times. At the present time numerous shieldings are being designed considering dose restrictions in real times of exposure. After these new shieldings, the dose rates could be notably superior to those after traditional shieldings, without it implies inadequate designs or constructive errors. In the work significant differences in levels of dose rates and thickness of shieldings estimated by both methods for some typical facilities. It was concluded that the use of real times of exposure is more adequate for the optimization of the Radiological Protection, although this method demands bigger care in its application. (Author)
Several problems in accelerator shielding study
International Nuclear Information System (INIS)
Nakamura, Takashi; Hirayama, Hideo; Ban, Shuichi.
1980-01-01
Recently, the utilization of accelerators has increased rapidly, and the increase of accelerating energy and beam intensity is also remarkable. The studies on accelerator shielding have become important, because the amount of radiation emitted from accelerators increased, the regulation of the dose of environmental radiation was tightened, and the cost of constructing shielding rose. As the plans of constructing large accelerators have been made successively, the survey on the present state and the problems of the studies on accelerator shielding was carried out. Accelerators are classified into electron accelerators and proton accelerators in view of the studies on shielding. In order to start the studies on accelerator shielding, first, the preparation of the cross section data is indispensable. The cross sections for generating Bremsstrahlung, photonuclear reactions generating neutrons, generation of neutrons by hadrons, nuclear reaction of neutrons and generation of gamma-ray by hadrons are described. The generation of neutrons and gamma-ray as the problems of thick targets is explained. The shielding problems are complex and diversified, but in this paper, the studies on the shielding, by which basic data are obtainable, are taken up, such as beam damping and side wall shielding. As for residual radioactivity, main nuclides and the difference of residual radioactivity according to substances have been studied. (J.P.N.)
Shielding concerns at a spallation source
International Nuclear Information System (INIS)
Russell, G.J.; Robinson, H.; Legate, G.L.; Woods, R.
1989-01-01
Neutrons produced by 800-MeV proton reactions at the Los Alamos Neutron Scattering Center spallation neutron source cause a variety of challenging shielding problems. We identify several characteristics distinctly different from reactor shielding and compute the dose attenuation through an infinite slab/shield composed of iron (100 cm) and borated polyethylene (15 cm). Our calculations show that (for an incident spallation spectrum characteristic of neutrons leaking from a tungsten target at 90/degree/) the dose through the shield is a complex mixture of neutrons and gamma rays. High-energy (> 20 MeV) neutron production from the target is ≅5% of the total, yet causes ≅68% of the dose at the shield surface. Primary low-energy (< 20 MeV) neutrons from the target contribute negligibly (≅0.5%) to the dose at the shield surface yet cause gamma rays, which contribute ≅31% to the total dose at the shield surface. Low-energy neutrons from spallation reactions behave similarly to neutrons with a fission spectrum distribution. 6 refs., 8 figs., 1 tab
Highly heat removing radiation shielding material
International Nuclear Information System (INIS)
Asano, Norio; Hozumi, Masahiro.
1990-01-01
Organic materials, inorganic materials or metals having excellent radiation shielding performance are impregnated into expanded metal materials, such as Al, Cu or Mg, having high heat conductivity. Further, the porosity of the expanded metals and combination of the expanded metals and the materials to be impregnated are changed depending on the purpose. Further, a plurality of shielding materials are impregnated into the expanded metal of the same kind, to constitute shielding materials. In such shielding materials, impregnated materials provide shielding performance against radiation rays such as neutrons and gamma rays, the expanded metals provide heat removing performance respectively and they act as shielding materials having heat removing performance as a whole. Accordingly, problems of non-informity and discontinuity in the prior art can be dissolved be provide materials having flexibility in view of fabrication work. (T.M.)
Gonadal Shielding in Radiography: A Best Practice?
Fauber, Terri L
2016-11-01
To investigate radiation dose to phantom testes with and without shielding. A male anthropomorphic pelvis phantom was imaged with thermoluminescent dosimeters (TLDs) placed in the right and left detector holes corresponding to the testes. Ten exposures were made of the pelvis with and without shielding. The exposed TLDs were packaged securely and mailed to the University of Wisconsin Calibration Laboratory for reading and analysis. A t test was calculated for the 2 exposure groups (no shield and shielded) and found to be significant, F = 8.306, P shield was used during pelvic imaging. Using a flat contact shield during imaging of the adult male pelvis significantly reduces radiation dose to the testes. Regardless of the contradictions in the literature on gonadal shielding, the routine practice of shielding adult male gonads during radiographic imaging of the pelvis is a best practice. © 2016 American Society of Radiologic Technologists.
Estimating ISABELLE shielding requirements
International Nuclear Information System (INIS)
Stevens, A.J.; Thorndike, A.M.
1976-01-01
Estimates were made of the shielding thicknesses required at various points around the ISABELLE ring. Both hadron and muon requirements are considered. Radiation levels at the outside of the shield and at the BNL site boundary are kept at or below 1000 mrem per year and 5 mrem/year respectively. Muon requirements are based on the Wang formula for pion spectra, and the hadron requirements on the hadron cascade program CYLKAZ of Ranft. A muon shield thickness of 77 meters of sand is indicated outside the ring in one area, and hadron shields equivalent to from 2.7 to 5.6 meters in thickness of sand above the ring. The suggested safety allowance would increase these values to 86 meters and 4.0 to 7.2 meters respectively. There are many uncertainties in such estimates, but these last figures are considered to be rather conservative
Selective shielding device for scintiphotography
International Nuclear Information System (INIS)
Harper, J.W.; Kay, T.D.
1976-01-01
A selective shielding device to be used in combination with a scintillation camera is described. The shielding device is a substantially oval-shaped configuration removably secured to the scintillation camera. As a result of this combination scanning of preselected areas of a patient can be rapidly and accurately performed without the requirement of mounting any type of shielding paraphernalia on the patient. 1 claim, 2 drawing figures
International Nuclear Information System (INIS)
Matsumoto, Akio; Isobe, Eiji.
1976-01-01
Purpose: To increase the shielding capacity of the radiation shielding material having an abundant flexibility. Constitution: A mat consisting of a lead or lead alloy fibrous material is covered with a cloth, and the two are made integral by sewing in a kilted fashion by using a yarn. Thereafter, the system is covered with a gas-tight film or sheet. The shielding material obtained in this way has, in addition to the above merits, advantages in that (1) it is free from restoration due to elasticity so that it can readily seal contaminants, (2) it can be used in a state consisting of a number of overlapped layers, (3) it fits the shoulder well and is readily portable and (4) it permits attachment of fasteners or the like. (Ikeda, J.)
Radiation shielding in dental radiography
International Nuclear Information System (INIS)
Stenstroem, B.; Rehnmark-Larsson, S.; Julin, P.; Richter, S.
1983-01-01
The protective effect in the thyroid region from different types of radiation shieldings at intraoral radiography has been studied as well as the reduction of the absorbed dose to the sternal and the gonadal regions. The shieldings tested were five different types of leaded aprons, of which three had an attached leaded collar and the other two were used in combination with separate soft leaded collars. Furthermore one of the soft leaded collars and an unflexible horizontal leaded shield were tested separately. Two dental x-ray machines of 60 and 65 kVp with rectangular and circular tube collimators were used. The exposure time corresponded to speed group E film. The absorbed doses were measured with two ionization chambers. No significant difference in the protective effect in the thyroid gland could be found between the different types of radiation shieldings. There was a dose reduction by approximately a factor of 2 to the thyroid region down to 0.08 mGy per full survey using parallelling technique, and below 0.001 mGy per single bitewing exposure. The shieldings reduced the thyroid dose using bisecting-angle technique by a factor of 5 down to 0.15 mGy per full survey (20 exposures). In the sternal region the combinations of apron and collar reduced the absorbed dose from a full survey to below 2 μGy compared with 18 μGy (parallelling) and 31 μGy (biscting-angle) without any shielding. With the horizontal leaded shield a reduction by a factor of 6 was obtained but no significant sternal dose reduction could be detected from the soft collar alone. The gonadal dose could be reduced by a factor of 10 with the horizontal leaded shield, parallelling technique and circular collimator. Using leaded aprons the gonadal dose was approximately one per cent of the dose without any shielding, i.e. below 0.01 μGy per single intraoral exposure. (Authors)
International Nuclear Information System (INIS)
Libotte, Rafael Barbosa; Alves Filho, Hermes; Oliva, Amaury Muñoz
2017-01-01
The physical phenomenon of transport of neutral particles in a host environment is of interest in various scientific applications, e.g., nuclear reactors, shielding calculations, radiological protection, nuclear medicine, agronomy, materials science, oil prospecting, etc. In all these areas there is a need for an accurate description of the transport of the particles in the host medium. In this class of applications are the neutron shielding problems, also referred to as 'fixed-source' problems, where the interaction of the particles with the medium does not produce new neutrons, i.e., non-multiplicative medium. In this context, the development of tools that model these problems is relevant and of a beneficial return to society. In this work, we propose the development of deterministic mathematical and computational modeling of neutron transport using the linearized equation of Boltzmann applied to neutron shielding problems. Here we present also the development of a spectro-nodal method (coarse mesh) considering the scattering phenomenon as being linearly anisotropic. We show the results using a computational application, developed in Java language, version 1.8.0 9 1
International Nuclear Information System (INIS)
Mason, Grant W.; Spencer, Ross L.
2002-01-01
The 'self-shielding' m=1 diocotron mode in Malmberg-Penning traps has been known for over a decade to be unstable for finite length non-neutral plasmas with hollow density profiles. Early theoretical efforts were unsuccessful in accounting for the exponential growth and/or the magnitude of the growth rate. Recent theoretical work has sought to resolve the discrepancy either as a consequence of the shape of the plasma ends or as a kinetic effect resulting from a modified distribution function as a consequence of the protocol used to form the hollow profiles in experiments. Both of these finite length mechanisms have been investigated in selected test cases using a three-dimensional particle-in-cell code that allows realistic treatment of shape and kinetic effects. A persistent discrepancy of a factor of 2-3 remains between simulation and experimental values of the growth rate. Simulations reported here are more in agreement with theoretical predictions and fail to explain the discrepancy