WorldWideScience

Sample records for advanced micro-sample methods

  1. In-air micro-pixe analysis of tissue samples

    International Nuclear Information System (INIS)

    Tanaka, A.; Ishii, K.; Komori, Y.

    2002-01-01

    Micro-PIXE is capable of providing spatial distributions of elements in the micro-meter scale and its application to biology is useful to elucidate the cellular metabolism. Since, in this method, a sample target is usually irradiated with proton or α-particle beams in vacuum, beam heating results in evaporation of volatile elements an shrinking of the sample. In order to avoid these side effects, we previously developed a technique of in-air micro-PIXE analysis for samples of cultured cells. In addition to these, analysis of exposed tissue samples from living subjects is highly desirable in biological and medical research. Here, we describe a technique of in-air micro-PIXE analysis of such tissue samples. The target samples of exposed tissue slices from a Donryu rat, in which a tumor had been transplanted, were analyzed with proton micro-beams of 2.6 MeV. We report that the shape of cells and the distribution of volatile elements in the tissue sample remain uncharged when using a target preparation based on a freeze-drying method. (author)

  2. Methods for the measurement of micro material evidence

    International Nuclear Information System (INIS)

    Yang Mingtai; Wang Wen; Wu Lunqiang; Dai Changsong

    2012-01-01

    The micro material evidence has been used in judicature litigation successfully, that must base on impersonal authentication with the advanced and proper methods. The basic principle, main trait, applicable range, analysis minimum and sensitive limit of twelve type instruments used in micro material evidence analysis have been related. Those could supply optional proper methods for micro material evidence. (authors)

  3. Recent advances in micro-vibration isolation

    Science.gov (United States)

    Liu, Chunchuan; Jing, Xingjian; Daley, Steve; Li, Fengming

    2015-05-01

    Micro-vibration caused by disturbance sources onboard spacecraft can severely degrade the working environment of sensitive payloads. Some notable vibration control methods have been developed particularly for the suppression or isolation of micro-vibration over recent decades. Usually, passive isolation techniques are deployed in aerospace engineering. Active isolators, however, are often proposed to deal with the low frequency vibration that is common in spacecraft. Active/passive hybrid isolation has also been effectively used in some spacecraft structures for a number of years. In semi-active isolation systems, the inherent structural performance can be adjusted to deal with variation in the aerospace environment. This latter approach is potentially one of the most practical isolation techniques for micro-vibration isolation tasks. Some emerging advanced vibration isolation methods that exploit the benefits of nonlinearity have also been reported in the literature. This represents an interesting and highly promising approach for solving some challenging problems in the area. This paper serves as a state-of-the-art review of the vibration isolation theory and/or methods which were developed, mainly over the last decade, specifically for or potentially could be used for, micro-vibration control.

  4. Optimization of a method based on micro-matrix solid-phase dispersion (micro-MSPD for the determination of PCBs in mussel samples

    Directory of Open Access Journals (Sweden)

    Nieves Carro

    2017-03-01

    Full Text Available This paper reports the development and optimization of micro-matrix solid-phase dispersion (micro-MSPD of nine polychlorinated biphenyls (PCBs in mussel samples (Mytilus galloprovincialis by using a two-level factorial design. Four variables (amount of sample, anhydrous sodium sulphate, Florisil and solvent volume were considered as factors in the optimization process. The results suggested that only the interaction between the amount of anhydrous sodium sulphate and the solvent volume was statistically significant for the overall recovery of a trichlorinated compound, CB 28. Generally most of the considered species exhibited a similar behaviour, the sample and Florisil amounts had a positive effect on PCBs extractions and solvent volume and sulphate amount had a negative effect. The analytical determination and confirmation of PCBs were carried out by using GC-ECD and GC-MS/MS, respectively. The method was validated having satisfactory precision and accuracy with RSD values below 6% and recoveries between 81 and 116% for all congeners. The optimized method was applied to the extraction of real mussel samples from two Galician Rías.

  5. Advanced Markov chain Monte Carlo methods learning from past samples

    CERN Document Server

    Liang, Faming; Carrol, Raymond J

    2010-01-01

    This book provides comprehensive coverage of simulation of complex systems using Monte Carlo methods. Developing algorithms that are immune to the local trap problem has long been considered as the most important topic in MCMC research. Various advanced MCMC algorithms which address this problem have been developed include, the modified Gibbs sampler, the methods based on auxiliary variables and the methods making use of past samples. The focus of this book is on the algorithms that make use of past samples. This book includes the multicanonical algorithm, dynamic weighting, dynamically weight

  6. MicroED data collection and processing

    Energy Technology Data Exchange (ETDEWEB)

    Hattne, Johan; Reyes, Francis E.; Nannenga, Brent L.; Shi, Dan; Cruz, M. Jason de la [Janelia Research Campus, Howard Hughes Medical Institute, Ashburn, VA 20147 (United States); Leslie, Andrew G. W. [Medical Research Council Laboratory of Molecular Biology, Cambridge (United Kingdom); Gonen, Tamir, E-mail: gonent@janelia.hhmi.org [Janelia Research Campus, Howard Hughes Medical Institute, Ashburn, VA 20147 (United States)

    2015-07-01

    The collection and processing of MicroED data are presented. MicroED, a method at the intersection of X-ray crystallography and electron cryo-microscopy, has rapidly progressed by exploiting advances in both fields and has already been successfully employed to determine the atomic structures of several proteins from sub-micron-sized, three-dimensional crystals. A major limiting factor in X-ray crystallography is the requirement for large and well ordered crystals. By permitting electron diffraction patterns to be collected from much smaller crystals, or even single well ordered domains of large crystals composed of several small mosaic blocks, MicroED has the potential to overcome the limiting size requirement and enable structural studies on difficult-to-crystallize samples. This communication details the steps for sample preparation, data collection and reduction necessary to obtain refined, high-resolution, three-dimensional models by MicroED, and presents some of its unique challenges.

  7. Micro-scaled high-throughput digestion of plant tissue samples for multi-elemental analysis

    Directory of Open Access Journals (Sweden)

    Husted Søren

    2009-09-01

    improvement of the micronutrient density in edible plant parts. Compared to existing vial-in-vial systems, the new method developed here represents a significant methodological advancement in terms of higher capacity, reduced labour consumption, lower material costs, less contamination and, as a consequence, improved analytical accuracy following micro-scaled digestion of plant samples.

  8. MicroRNA Expression in Laser Micro-dissected Breast Cancer Tissue Samples - a Pilot Study.

    Science.gov (United States)

    Seclaman, Edward; Narita, Diana; Anghel, Andrei; Cireap, Natalia; Ilina, Razvan; Sirbu, Ioan Ovidiu; Marian, Catalin

    2017-10-28

    Breast cancer continues to represent a significant public health burden despite outstanding research advances regarding the molecular mechanisms of cancer biology, biomarkers for diagnostics and prognostic and therapeutic management of this disease. The studies of micro RNAs in breast cancer have underlined their potential as biomarkers and therapeutic targets; however most of these studies are still done on largely heterogeneous whole breast tissue samples. In this pilot study we have investigated the expression of four micro RNAs (miR-21, 145, 155, 92) known to be involved in breast cancer, in homogenous cell populations collected by laser capture microdissection from breast tissue section slides. Micro RNA expression was assessed by real time PCR, and associations with clinical and pathological characteristics were also explored. Our results have confirmed previous associations of miR-21 expression with poor prognosis characteristics of breast cancers such as high stage, large and highly proliferative tumors. No statistically significant associations were found with the other micro RNAs investigated, possibly due to the small sample size of our study. Our results also suggest that miR-484 could be a suitable endogenous control for data normalization in breast tissues, these results needing further confirmation by future studies. In summary, our pilot study showed the feasibility of detecting micro RNAs expression in homogenous laser captured microdissected invasive breast cancer samples, and confirmed some of the previously reported associations with poor prognostic characteristics of breast tumors.

  9. A modified FOX-1 method for Micro-determination of hydrogen peroxide in honey samples.

    Science.gov (United States)

    Li, Dan; Wang, Meng; Cheng, Ni; Xue, Xiaofeng; Wu, Liming; Cao, Wei

    2017-12-15

    Hydrogen peroxide (H 2 O 2 ) is a major antibacterial activity-associated biomarker in honey. Measurement of endogenous H 2 O 2 in honey is of great value in prediction of the H 2 O 2 -depended antibacterial activity and characterization or selection of honey samples for their use as an antibacterial agent or natural food preservative. Considering current methods for H 2 O 2 determination are either time-consuming or complicated with their high-cost, a study was conducted to modify and validate the spectrophotometry-based ferrous oxidation-xylenol orange (FOX-1) method for micro-determination of H 2 O 2 in honey samples. The result suggested that the proposed FOX-1 method is fast, sensitive, precise and repeatable. The method was successfully applied for the analysis of a total of 35 honey samples from 5 floral origins and 33 geographical origins. The proposed method is low-cost and easy-to-run, and it can be considered by researchers and industry for routine analysis. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Evaluation of a new tear osmometer for repeatability and accuracy, using 0.5-microL (500-Nanoliter) samples.

    Science.gov (United States)

    Yildiz, Elvin H; Fan, Vincent C; Banday, Hina; Ramanathan, Lakshmi V; Bitra, Ratna K; Garry, Eileen; Asbell, Penny A

    2009-07-01

    To evaluate the repeatability and accuracy of a new tear osmometer that measures the osmolality of 0.5-microL (500-nanoliter) samples. Four standardized solutions were tested with 0.5-microL (500-nanoliter) samples for repeatability of measurements and comparability to standardized technique. Two known standard salt solutions (290 mOsm/kg H2O, 304 mOsm/kg H2O), a normal artificial tear matrix sample (306 mOsm/kg H2O), and an abnormal artificial tear matrix sample (336 mOsm/kg H2O) were repeatedly tested (n = 20 each) for osmolality with use of the Advanced Instruments Model 3100 Tear Osmometer (0.5-microL [500-nanoliter] sample size) and the FDA-approved Advanced Instruments Model 3D2 Clinical Osmometer (250-microL sample size). Four standard solutions were used, with osmolality values of 290, 304, 306, and 336 mOsm/kg H2O. The respective precision data, including the mean and standard deviation, were: 291.8 +/- 4.4, 305.6 +/- 2.4, 305.1 +/- 2.3, and 336.4 +/- 2.2 mOsm/kg H2O. The percent recoveries for the 290 mOsm/kg H2O standard solution, the 304 mOsm/kg H2O reference solution, the normal value-assigned 306 mOsm/kg H2O sample, and the abnormal value-assigned 336 mOsm/kg H2O sample were 100.3, 100.2, 99.8, and 100.3 mOsm/kg H2O, respectively. The repeatability data are in accordance with data obtained on clinical osmometers with use of larger sample sizes. All 4 samples tested on the tear osmometer have osmolality values that correlate well to the clinical instrument method. The tear osmometer is a suitable instrument for testing the osmolality of microliter-sized samples, such as tears, and therefore may be useful in diagnosing, monitoring, and classifying tear abnormalities such as the severity of dry eye disease.

  11. A Study of Simple α Source Preparation Using a Micro-coprecipitation Method

    International Nuclear Information System (INIS)

    Lee, Myung Ho; Park, Taehong; Song, Byung Chul; Park, Jong Ho; Song, Kyuseok

    2012-01-01

    This study presents a rapid and simple α source preparation method for a radioactive waste sample. The recovery of 239 Pu, 232 U and 243 Am using a micro-coprecipitation method was over 95%. The α-peak resolution of Pu and Am isotopes through the micro-coprecipitation method is enough to discriminate the Pu and Am isotopes from other Pu and Am isotopes. The determination of the Pu and Am isotopes using the micro-coprecipitation method was applied to the radioactive waste sample, so that the activity concentrations of the Pu and Am isotopes using the micro-coprecipitation method in the radioactive waste sample were similar to those using the electrodeposition method

  12. MicroRNA Expression Profile in the Prenatal Amniotic Fluid Samples of Pregnant Women with Down Syndrome.

    Science.gov (United States)

    Karaca, Emin; Aykut, Ayça; Ertürk, Biray; Durmaz, Burak; Güler, Ahmet; Büke, Barış; Yeniel, Ahmet Özgür; Ergenoğlu, Ahmet Mete; Özkınay, Ferda; Özeren, Mehmet; Kazandı, Mert; Akercan, Fuat; Sağol, Sermet; Gündüz, Cumhur; Çoğulu, Özgür

    2018-03-15

    Down syndrome, which is the most common human chromosomal anomaly that can affect people of any race and age, can be diagnosed prenatally in most cases. Prenatal diagnosis via culture method is time-consuming; thus, genetic analysis has thus been introduced and is continually being developed for rapid prenatal diagnosis. For this reason, the effective use of microRNA profiling for the rapid analysis of prenatal amniotic fluid samples for the diagnosis of Down syndrome was investigated. To evaluate the expression levels of 14 microRNAs encoded by chromosome 21 in amniotic fluid samples and their utility for prenatal diagnosis of Down syndrome. Case-control study. We performed invasive prenatal testing for 56 pregnant women; 23 carried fetuses with Down syndrome, and 33 carried fetuses with a normal karyotype. Advanced maternal age and increased risk for Down syndrome in the screening tests were indications for invasive prenatal testing. The age of gestation in the study and control groups ranged between 17 and 18 weeks. The expression levels of microRNA were measured by real-time polymerase chain reaction. The expression levels of microRNA-125b-2, microRNA-155 , and microRNA-3156 were significantly higher in the study group than in the control group. The presence of significantly dysregulated microRNAs may be associated with either the phenotype or the result of abnormal development. Further large-scale comparative studies conducted in a variety of conditions may bring novel insights in the field of abnormal prenatal conditions.

  13. Advanced control of piezoelectric micro-nano-positioning systems

    CERN Document Server

    Xu, Qingsong

    2016-01-01

    This book explores emerging methods and algorithms that enable precise control of micro-/nano-positioning systems. The text describes three control strategies: hysteresis-model-based feedforward control and hysteresis-model-free feedback control based on and free from state observation. Each paradigm receives dedicated attention within a particular part of the text. Readers are shown how to design, validate and apply a variety of new control approaches in micromanipulation: hysteresis modelling, discrete-time sliding-mode control and model-reference adaptive control. Experimental results are provided throughout and build up to a detailed treatment of practical applications in the fourth part of the book. The applications focus on control of piezoelectric grippers. Advanced Control of Piezoelectric Micro-/Nano-Positioning Systems will assist academic researchers and practising control and mechatronics engineers interested in suppressing sources of nonlinearity such as hysteresis and drift when combining positi...

  14. Exploring biomolecular dynamics and interactions using advanced sampling methods

    International Nuclear Information System (INIS)

    Luitz, Manuel; Bomblies, Rainer; Ostermeir, Katja; Zacharias, Martin

    2015-01-01

    Molecular dynamics (MD) and Monte Carlo (MC) simulations have emerged as a valuable tool to investigate statistical mechanics and kinetics of biomolecules and synthetic soft matter materials. However, major limitations for routine applications are due to the accuracy of the molecular mechanics force field and due to the maximum simulation time that can be achieved in current simulations studies. For improving the sampling a number of advanced sampling approaches have been designed in recent years. In particular, variants of the parallel tempering replica-exchange methodology are widely used in many simulation studies. Recent methodological advancements and a discussion of specific aims and advantages are given. This includes improved free energy simulation approaches and conformational search applications. (topical review)

  15. Recent advances in graphene-based planar micro-supercapacitors for on-chip energy storage

    Institute of Scientific and Technical Information of China (English)

    Zhong-Shuai Wu; Xinliang Feng; Hui-Ming Cheng

    2014-01-01

    The current development trend towards miniaturized portable electronic devices has signiicantly increased the demand for ultrathin, lexible and sustainable on-chip micro-supercapacitors that have enormous potential to complement, or even to replace, micro-bateries and electrolytic capacitors. In this regard,graphene-based micro-supercapacitors with a planar geometry are promising micro-electrochemical energy-storage devices that can take full advantage of planar coniguration and unique features of graphene.his review summarizes the latest advances in on-chip graphene-based planar interdigital micro-supercapacitors, from the history of their development, representative graphene-based materials(graphene sheets, graphene quantum dots and graphene hybrids) for their manufacture, typical microfabrication strategies(photolithography techniques, electrochemical methods, laser writing, etc.),electrolyte(aqueous, organic, ionic and gel), to device coniguration(symmetric and asymmetric). Finally,the perspectives and possible development directions of future graphene-based micro-supercapacitors are briely discussed.

  16. Recent results of the investigation of a micro-fluidic sampling chip and sampling system for hot cell aqueous processing streams

    International Nuclear Information System (INIS)

    Tripp, J.; Smith, T.; Law, J.

    2013-01-01

    A Fuel Cycle Research and Development project has investigated an innovative sampling method that could evolve into the next generation sampling and analysis system for metallic elements present in aqueous processing streams. Initially sampling technologies were evaluated and micro-fluidic sampling chip technology was selected and tested. A conceptual design for a fully automated microcapillary-based system was completed and a robotic automated sampling system was fabricated. The mechanical and sampling operation of the completed sampling system was investigated. Different sampling volumes have been tested. It appears that the 10 μl volume has produced data that had much smaller relative standard deviations than the 2 μl volume. In addition, the production of a less expensive, mass produced sampling chip was investigated to avoid chip reuse thus increasing sampling reproducibility/accuracy. The micro-fluidic-based robotic sampling system's mechanical elements were tested to ensure analytical reproducibility and the optimum robotic handling of micro-fluidic sampling chips. (authors)

  17. A Proposal on the Advanced Sampling Based Sensitivity and Uncertainty Analysis Method for the Eigenvalue Uncertainty Analysis

    International Nuclear Information System (INIS)

    Kim, Song Hyun; Song, Myung Sub; Shin, Chang Ho; Noh, Jae Man

    2014-01-01

    In using the perturbation theory, the uncertainty of the response can be estimated by a single transport simulation, and therefore it requires small computational load. However, it has a disadvantage that the computation methodology must be modified whenever estimating different response type such as multiplication factor, flux, or power distribution. Hence, it is suitable for analyzing few responses with lots of perturbed parameters. Statistical approach is a sampling based method which uses randomly sampled cross sections from covariance data for analyzing the uncertainty of the response. XSUSA is a code based on the statistical approach. The cross sections are only modified with the sampling based method; thus, general transport codes can be directly utilized for the S/U analysis without any code modifications. However, to calculate the uncertainty distribution from the result, code simulation should be enough repeated with randomly sampled cross sections. Therefore, this inefficiency is known as a disadvantage of the stochastic method. In this study, an advanced sampling method of the cross sections is proposed and verified to increase the estimation efficiency of the sampling based method. In this study, to increase the estimation efficiency of the sampling based S/U method, an advanced sampling and estimation method was proposed. The main feature of the proposed method is that the cross section averaged from each single sampled cross section is used. For the use of the proposed method, the validation was performed using the perturbation theory

  18. The scope of detector Medipix2 in micro-radiography of biological samples

    Energy Technology Data Exchange (ETDEWEB)

    Dammer, J., E-mail: jiri.dammer@utef.cvut.cz [Institute of Experimental and Applied Physics, Czech Technical University in Prague, Horska 3a/22, CZ-12800 Prague 2 (Czech Republic); Weyda, F. [Biology Centre of the Academy of Sciences of the Czech Republic, Institute of Entomology, Branisovska 31, CZ-37005 Ceske Budejovice (Czech Republic); Faculty of Science, University of South Bohemia, Branisovska 31, CZ-37005 Ceske Budejovice (Czech Republic); Jakubek, J. [Institute of Experimental and Applied Physics, Czech Technical University in Prague, Horska 3a/22, CZ-12800 Prague 2 (Czech Republic); Skrabal, P. [Faculty of Biomedical Engineering, Czech Technical University in Prague, Nam. Sitna 3105, CZ-272 01 Kladno (Czech Republic); Sopko, V.; Vavrik, D. [Institute of Experimental and Applied Physics, Czech Technical University in Prague, Horska 3a/22, CZ-12800 Prague 2 (Czech Republic)

    2011-05-15

    We present our experimental setup devoted to high resolution X-ray micro-radiography that is suitable for imaging of small biological samples. The photon source is a FeinFocus micro-focus X-ray tube. The single photon counting pixel device Medipix2 serves as imaging area. Recently used imaging detectors as radiography films or scintillator detectors, cannot visualize required information about inner structure of scanned sample. Detectors Medipix2 do not suffer from so-called dark current noise and work in unlimited dynamic range. These features of detectors confer high quality and high contrast of final images. The radiographic imaging with detectors Medipix2 represents non-invasive and non-destructive method of investigation. Hereby, we demonstrate results of micro-radiographic study of internal structures of tiny biological samples. In addition to morphological and anatomical studies, we would like to present preliminary study of dynamic processes inside of organisms using micro-radiographic video-capturing.

  19. The scope of detector Medipix2 in micro-radiography of biological samples

    International Nuclear Information System (INIS)

    Dammer, J.; Weyda, F.; Jakubek, J.; Skrabal, P.; Sopko, V.; Vavrik, D.

    2011-01-01

    We present our experimental setup devoted to high resolution X-ray micro-radiography that is suitable for imaging of small biological samples. The photon source is a FeinFocus micro-focus X-ray tube. The single photon counting pixel device Medipix2 serves as imaging area. Recently used imaging detectors as radiography films or scintillator detectors, cannot visualize required information about inner structure of scanned sample. Detectors Medipix2 do not suffer from so-called dark current noise and work in unlimited dynamic range. These features of detectors confer high quality and high contrast of final images. The radiographic imaging with detectors Medipix2 represents non-invasive and non-destructive method of investigation. Hereby, we demonstrate results of micro-radiographic study of internal structures of tiny biological samples. In addition to morphological and anatomical studies, we would like to present preliminary study of dynamic processes inside of organisms using micro-radiographic video-capturing.

  20. Micro-sampling method based on high-resolution continuum source graphite furnace atomic absorption spectrometry for calcium determination in blood and mitochondrial suspensions.

    Science.gov (United States)

    Gómez-Nieto, Beatriz; Gismera, Mª Jesús; Sevilla, Mª Teresa; Satrústegui, Jorgina; Procopio, Jesús R

    2017-08-01

    A micro-sampling and straightforward method based on high resolution continuum source atomic absorption spectrometry (HR-CS AAS) was developed to determine extracellular and intracellular Ca in samples of interest in clinical and biomedical analysis. Solid sampling platforms were used to introduce the micro-samples into the graphite furnace atomizer. The secondary absorption line for Ca, located at 239.856nm, was selected to carry out the measurements. Experimental parameters such as pyrolysis and atomization temperatures and the amount of sample introduced for the measurements were optimized. Calibration was performed using aqueous standards and the approach to measure at the wings of the absorption lines was employed for the expansion of the linear response range. The limit of detection was of 0.02mgL -1 Ca (0.39ng Ca) and the upper limit of linear range was increased up to 8.0mgL -1 Ca (160ng Ca). The proposed method was used to determine Ca in mitochondrial suspensions and whole blood samples with successful results. Adequate recoveries (within 91-107%) were obtained in the tests performed for validation purposes. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Canonical vs. micro-canonical sampling methods in a 2D Ising model

    International Nuclear Information System (INIS)

    Kepner, J.

    1990-12-01

    Canonical and micro-canonical Monte Carlo algorithms were implemented on a 2D Ising model. Expressions for the internal energy, U, inverse temperature, Z, and specific heat, C, are given. These quantities were calculated over a range of temperature, lattice sizes, and time steps. Both algorithms accurately simulate the Ising model. To obtain greater than three decimal accuracy from the micro-canonical method requires that the more complicated expression for Z be used. The overall difference between the algorithms is small. The physics of the problem under study should be the deciding factor in determining which algorithm to use. 13 refs., 6 figs., 2 tabs

  2. Determination of methylmercury in marine biota samples with advanced mercury analyzer: method validation.

    Science.gov (United States)

    Azemard, Sabine; Vassileva, Emilia

    2015-06-01

    In this paper, we present a simple, fast and cost-effective method for determination of methyl mercury (MeHg) in marine samples. All important parameters influencing the sample preparation process were investigated and optimized. Full validation of the method was performed in accordance to the ISO-17025 (ISO/IEC, 2005) and Eurachem guidelines. Blanks, selectivity, working range (0.09-3.0ng), recovery (92-108%), intermediate precision (1.7-4.5%), traceability, limit of detection (0.009ng), limit of quantification (0.045ng) and expanded uncertainty (15%, k=2) were assessed. Estimation of the uncertainty contribution of each parameter and the demonstration of traceability of measurement results was provided as well. Furthermore, the selectivity of the method was studied by analyzing the same sample extracts by advanced mercury analyzer (AMA) and gas chromatography-atomic fluorescence spectrometry (GC-AFS). Additional validation of the proposed procedure was effectuated by participation in the IAEA-461 worldwide inter-laboratory comparison exercises. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Advanced free-form micro tooling

    DEFF Research Database (Denmark)

    Tosello, Guido; Gavillet, J.

    2011-01-01

    -beam lithography and nano imprinting lithography [Che05][Che09] have high manufacturing cost and a low throughput. The aim was obtain large tool area with nano structures patterning without using energy intensive nano machining (e.g. focus ion beam, X-ray lithography, etc) but, instead, by exploiting the advantage......The present deliverable contains the report of the work and results achieved within the framework of WP 2.2 in Tasks 2.2.4 “Advanced free-form micro tooling” in experimental research done regarding practical applications of methods of applying nano structures to tooling solutions. As part of Task 2.......2.4, tests based on three different chemical-based-batch techniques to establish surface nano (i.e. sub-μm) structures on large tools area were performed. The three approached regarded: o Scheme 1  The use of Ø500nm nanobeads deposition for direct patterning of a Ø4inch. silicon wafer and subsequent nickel...

  4. Fuel, structural material and coolant for an advanced fast micro-reactor

    International Nuclear Information System (INIS)

    Nascimento, Jamil A. do; Guimaraes, Lamartine N.F.; Ono, Shizuca

    2011-01-01

    The use of nuclear reactors in space, seabed or other Earth hostile environment in the future is a vision that some Brazilian nuclear researchers share. Currently, the USA, a leader in space exploration, has as long-term objectives the establishment of a permanent Moon base and to launch a manned mission to Mars. A nuclear micro-reactor is the power source chosen to provide energy for life support, electricity for systems, in these missions. A strategy to develop an advanced micro-reactor technologies may consider the current fast reactor technologies as back-up and the development of advanced fuel, structural and coolant materials. The next generation reactors (GEN-IV) for terrestrial applications will operate with high output temperature to allow advanced conversion cycle, such as Brayton, and hydrogen production, among others. The development of an advanced fast micro-reactor may create a synergy between the GEN-IV and space reactor technologies. Considering a set of basic requirements and materials properties this paper discusses the choice of advanced fuel, structural and coolant materials for a fast micro-reactor. The chosen candidate materials are: nitride, oxide as back-up, for fuel, lead, tin and gallium for coolant, ferritic MA-ODS and Mo alloys for core structures. The next step will be the neutronic and burnup evaluation of core concepts with this set of materials. (author)

  5. Two microRNA signatures for malignancy and immune infiltration predict overall survival in advanced epithelial ovarian cancer.

    Science.gov (United States)

    Korsunsky, Ilya; Parameswaran, Janaki; Shapira, Iuliana; Lovecchio, John; Menzin, Andrew; Whyte, Jill; Dos Santos, Lisa; Liang, Sharon; Bhuiya, Tawfiqul; Keogh, Mary; Khalili, Houman; Pond, Cassandra; Liew, Anthony; Shih, Andrew; Gregersen, Peter K; Lee, Annette T

    2017-10-01

    MicroRNAs have been established as key regulators of tumor gene expression and as prime biomarker candidates for clinical phenotypes in epithelial ovarian cancer (EOC). We analyzed the coexpression and regulatory structure of microRNAs and their co-localized gene targets in primary tumor tissue of 20 patients with advanced EOC in order to construct a regulatory signature for clinical prognosis. We performed an integrative analysis to identify two prognostic microRNA/mRNA coexpression modules, each enriched for consistent biological functions. One module, enriched for malignancy-related functions, was found to be upregulated in malignant versus benign samples. The second module, enriched for immune-related functions, was strongly correlated with imputed intratumoral immune infiltrates of T cells, natural killer cells, cytotoxic lymphocytes, and macrophages. We validated the prognostic relevance of the immunological module microRNAs in the publicly available The Cancer Genome Atlas data set. These findings provide novel functional roles for microRNAs in the progression of advanced EOC and possible prognostic signatures for survival. © American Federation for Medical Research (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  6. Distance sampling methods and applications

    CERN Document Server

    Buckland, S T; Marques, T A; Oedekoven, C S

    2015-01-01

    In this book, the authors cover the basic methods and advances within distance sampling that are most valuable to practitioners and in ecology more broadly. This is the fourth book dedicated to distance sampling. In the decade since the last book published, there have been a number of new developments. The intervening years have also shown which advances are of most use. This self-contained book covers topics from the previous publications, while also including recent developments in method, software and application. Distance sampling refers to a suite of methods, including line and point transect sampling, in which animal density or abundance is estimated from a sample of distances to detected individuals. The book illustrates these methods through case studies; data sets and computer code are supplied to readers through the book’s accompanying website.  Some of the case studies use the software Distance, while others use R code. The book is in three parts.  The first part addresses basic methods, the ...

  7. Resistance Welding of Advanced Materials and Micro Components

    DEFF Research Database (Denmark)

    Friis, Kasper Storgaard

    With the use of the Finite Element Method it has become possible to analyse and better understand complex physical processes such as the resistance welding by numerical simulation. However, simulation of resistance welding is a very complex matter due to the strong interaction between mechanical......, thermal, electrical and metallurgical effects all signifcantly in uencing the process. Modelling is further complicated when down-scaling the process for welding micro components or when welding new advanced high strength steels in the automotive industry. The current project deals with three main themes...... aimed at improving the understanding of resistance welding for increasing the accuracy of numerical simulation of the process. Firstly methods for measuring and modelling mechanical and electrical properties at a wide range of temperatures is investigated, and especially the electrical contact...

  8. Advanced Data Mining of Leukemia Cells Micro-Arrays

    Directory of Open Access Journals (Sweden)

    Richard S. Segall

    2009-12-01

    Full Text Available This paper provides continuation and extensions of previous research by Segall and Pierce (2009a that discussed data mining for micro-array databases of Leukemia cells for primarily self-organized maps (SOM. As Segall and Pierce (2009a and Segall and Pierce (2009b the results of applying data mining are shown and discussed for the data categories of microarray databases of HL60, Jurkat, NB4 and U937 Leukemia cells that are also described in this article. First, a background section is provided on the work of others pertaining to the applications of data mining to micro-array databases of Leukemia cells and micro-array databases in general. As noted in predecessor article by Segall and Pierce (2009a, micro-array databases are one of the most popular functional genomics tools in use today. This research in this paper is intended to use advanced data mining technologies for better interpretations and knowledge discovery as generated by the patterns of gene expressions of HL60, Jurkat, NB4 and U937 Leukemia cells. The advanced data mining performed entailed using other data mining tools such as cubic clustering criterion, variable importance rankings, decision trees, and more detailed examinations of data mining statistics and study of other self-organized maps (SOM clustering regions of workspace as generated by SAS Enterprise Miner version 4. Conclusions and future directions of the research are also presented.

  9. Development of a sample chamber for micro-PIXE

    International Nuclear Information System (INIS)

    Kurosawa, M.; Sueno, S.; Shima, K.; Ohshima, H.; Ishii, H.; Kamiya, H.; Kimoto, S.

    1997-01-01

    A new sample chamber for micro-PIXE analysis of geological thick samples has been successfully developed. A target in the sample chamber is normal to the beam and Si(Li) detectors are located at 135deg to the beam direction. For the sample observation, a normal viewing optics with the optical axis collinear with the beam is achieved by a combination of long working distance microscope and mirror with a central hole for the beam transmission. The normal incidence beam and normal viewing are essential to raise a spatial resolution of the thick target analysis. In addition, the sample chamber has fulfilled ten requirements as for material, driving stage, X-ray absorbers, space for another detector, etc. The information obtained by the development can give a new guide to manufacture the sample chamber for the micro-PIXE. (author)

  10. Advantages of infrared transflection micro spectroscopy and paraffin-embedded sample preparation for biological studies

    Science.gov (United States)

    Yao, Jie; Li, Qian; Zhou, Bo; Wang, Dan; Wu, Rie

    2018-04-01

    Fourier-Transform Infrared micro-spectroscopy is an excellent method for biological analyses. In this paper, series metal coating films on ITO glass were prepared by the electrochemical method and the different thicknesses of paraffin embedding rat's brain tissue on the substrates were studied by IR micro-spetroscopy in attenuated total reflection (ATR) mode and transflection mode respectively. The Co-Ni-Cu alloy coating film with low cost is good reflection substrates for the IR analysis. The infrared microscopic transflection mode needs not to touch the sample at all and can get the IR spectra with higher signal to noise ratios. The Paraffin-embedding method allows tissues to be stored for a long time for re-analysis to ensure the traceability of the sample. Also it isolates the sample from the metal and avoids the interaction of biological tissue with the metals. The best thickness of the tissues is 4 μm.

  11. Multi Scale Micro and Nano Metrology for Advanced Precision Moulding Technologies

    DEFF Research Database (Denmark)

    Quagliotti, Danilo

    dimensions of the novel micro and nano production. Nowadays, design methodologies and concurrent tolerance guidelines are not yet available for advanced micro manufacture. Moreover, there are no shared methodologies that deals with the uncertainty evaluation of feature of size in the sub-millimetre scale......The technological revolution that has deeply influenced the manufacturing industry over the past two decades opened up new possibilities for the realisation of advanced micro and nano systems but, at the same time, traditional techniques for quality assurance became not adequate any longer......, as the technology progressed. The gap between the needs of the manufacturing industry and the well-organized structure of the dimensional and geometrical metrology appeared, above all, related to the methodologies and, also, to the instrumentation used to deal with the incessant scaling down of the critical...

  12. Equivalent Simplification Method of Micro-Grid

    OpenAIRE

    Cai Changchun; Cao Xiangqin

    2013-01-01

    The paper concentrates on the equivalent simplification method for the micro-grid system connection into distributed network. The equivalent simplification method proposed for interaction study between micro-grid and distributed network. Micro-grid network, composite load, gas turbine synchronous generation, wind generation are equivalent simplification and parallel connect into the point of common coupling. A micro-grid system is built and three phase and single phase grounded faults are per...

  13. Methods for measuring the spectral reflectivity of advanced materials at high temperature

    International Nuclear Information System (INIS)

    Salikhov, T.P.; Kan, V.V.

    1993-01-01

    For investigation in the domain of advanced materials as well as for new technologies there is an urgent need for knowledge of the spectral reflectivity of the materials specially at high temperatures. However the methods available are mostly intended for measuring the model materials with specular or diffuse reflection surface. This is not quite correct since advanced materials have mixed specular diffuse reflection surfaces. New methods for reflectivity measurements of materials in the visible, near and middle infrared range at high temperature, regardless of surface texture, have been developed. The advantages of the methods proposed are as flows: (a) the facility of performing the reflectivity measurements for materials with mixed specular diffuse reflectance; (b) wide spectral range 0,38-8 micro m; (c) wide temperature range 300-3000 K; (d) high accuracy and rapid measurements. The methods are based on the following principals (i) Diffuse irradiation of the sample surface and the use of Helkholtz reciprocity principle to determine the directional hemispherical reflectivity ii) Pulse polychromatic probing of the sample by additional light source. The first principle excludes the influence of the angular reflection distribution of sample surface on data obtained. The second principle gives the possibility of simultaneous measurements of the reflectivity. The second principle gives the possibility of simultaneous measurements of the reflectivity in wide spectral range. On the basis of these principles for high temperature reflectometers have been developed and discussed here. (author)

  14. New Analytical Methods for the Surface/ Interface and the Micro-Structures in Advanced Nanocomposite Materials by Synchrotron Radiation

    Directory of Open Access Journals (Sweden)

    K. Nakamae

    2010-12-01

    Full Text Available Analytical methods of surface/interface structure and micro-structure in advanced nanocomposite materials by using the synchrotron radiation are introduced. Recent results obtained by the energy-tunable and highly collimated brilliant X-rays, in-situ wide angle/small angle X-ray diffraction with high accuracy are reviewed. It is shown that small angle X-ray scattering is one of the best methods to characterize nanoparticle dispersibility, filler aggregate/agglomerate structures and in-situ observation of hierarchical structure deformation in filled rubber under cyclic stretch. Grazing Incidence(small and wide angle X-ray Scattering are powerful to analyze the sintering process of metal nanoparticle by in-situ observation as well as the orientation of polymer molecules and crystalline orientation at very thin surface layer (ca 7nm of polymer film. While the interaction and conformation of adsorbed molecule at interface can be investigated by using high energy X-ray XPS with Enough deep position (ca 9 micron m.

  15. Advances in circulating microRNAs as diagnostic and prognostic markers for ovarian cancer

    International Nuclear Information System (INIS)

    Zheng, Hong; Liu, Jia-Yu; Song, Feng-Ju; Chen, Ke-Xin

    2013-01-01

    Ovarian cancer is one of the most lethal malignant gynecological tumors. More than 70% of patients with ovarian cancer are diagnosed at advanced stage. The 5-year survival in patients with advanced ovarian cancer is less than 30% because of the lack of effective biomarkers for diagnosis, prognosis, and personalized treatment. MicroRNA (miR) is a class of small noncoding RNAs that negatively regulate gene expression primarily through post-transcriptional repression. Many studies on tissue miR in ovarian cancer have been carried out and show great potential in clinical practice. However, tissue samples are not easily available because sampling causes injury. Researchers have started to focus on plasma/serum miR, assuming that blood samples may replace tissue samples in miR research in the future. Plasma/serum miR research is still in its early stages. Studies on its function in the early diagnosis of ovarian cancer have achieved some progress, but plasma/serum miR profiling for prognosis and personalized treatment of ovarian cancer remains unknown. A thorough understanding of the function of plasma/serum miR in ovarian cancer will facilitate early diagnosis and improve treatment for ovarian cancer

  16. Manipulation of biological samples using micro and nano techniques

    DEFF Research Database (Denmark)

    Castillo, Jaime; Dimaki, Maria; Svendsen, Winnie Edith

    2009-01-01

    to their natural structure. Thanks to the advances in micro- and nanofabrication during the last decades several manipulation techniques offer us the possibility to image, characterize and manipulate biological material in a controlled way. Using these techniques the integration of biomaterials with remarkable...

  17. Manipulation of biological samples using micro and nano techniques.

    Science.gov (United States)

    Castillo, Jaime; Dimaki, Maria; Svendsen, Winnie Edith

    2009-01-01

    The constant interest in handling, integrating and understanding biological systems of interest for the biomedical field, the pharmaceutical industry and the biomaterial researchers demand the use of techniques that allow the manipulation of biological samples causing minimal or no damage to their natural structure. Thanks to the advances in micro- and nanofabrication during the last decades several manipulation techniques offer us the possibility to image, characterize and manipulate biological material in a controlled way. Using these techniques the integration of biomaterials with remarkable properties with physical transducers has been possible, giving rise to new and highly sensitive biosensing devices. This article reviews the different techniques available to manipulate and integrate biological materials in a controlled manner either by sliding them along a surface (2-D manipulation), by grapping them and moving them to a new position (3-D manipulation), or by manipulating and relocating them applying external forces. The advantages and drawbacks are mentioned together with examples that reflect the state of the art of manipulation techniques for biological samples (171 references).

  18. Comparison of microRNA expression using different preservation methods of matched psoriatic skin samples

    DEFF Research Database (Denmark)

    Løvendorf, Marianne B; Zibert, John R; Hagedorn, Peter H

    2012-01-01

    MicroRNAs are non-coding RNA molecules modulating gene expression post-transcriptionally. Formalin-fixed, paraffin-embedding (FFPE) is a standard preservation method often used in clinical practices, but induces RNA degradation. Extracting high-quality RNA from human skin can be challenging as skin...

  19. Method Verification Requirements for an Advanced Imaging System for Microbial Plate Count Enumeration.

    Science.gov (United States)

    Jones, David; Cundell, Tony

    2018-01-01

    The Growth Direct™ System that automates the incubation and reading of membrane filtration microbial counts on soybean-casein digest, Sabouraud dextrose, and R2A agar differs only from the traditional method in that micro-colonies on the membrane are counted using an advanced imaging system up to 50% earlier in the incubation. Based on the recommendations in USP Validation of New Microbiological Testing Methods , the system may be implemented in a microbiology laboratory after simple method verification and not a full method validation. LAY ABSTRACT: The Growth Direct™ System that automates the incubation and reading of microbial counts on membranes on solid agar differs only from the traditional method in that micro-colonies on the membrane are counted using an advanced imaging system up to 50% earlier in the incubation time. Based on the recommendations in USP Validation of New Microbiological Testing Methods , the system may be implemented in a microbiology laboratory after simple method verification and not a full method validation. © PDA, Inc. 2018.

  20. Application of Micro-coprecipitation Method to Alpha Source Preparation for Measuring Alpha Nuclides

    International Nuclear Information System (INIS)

    Lee, Myung Ho; Park, Jong Ho; Oh, Se Jin; Song, Byung Chul; Song, Kyuseok

    2011-01-01

    Among the source preparations, an electrodeposition is a commonly used method for the preparation of sources for an alpha spectrometry, because this technique is simple and produces a very thin deposit, which is essential for a high resolution of the alpha peak. Recently, micro-coprecipitation with rare earths have been used to yield sources for -spectrometry. In this work, the Pu, Am and Cm isotopes were purified from hindrance nuclides and elements with an a TRU resin in radioactive waste samples, and the activity concentrations of the Pu, Am and Cm isotopes were determined by radiation counting methods after alpha source preparation like micro coprecipitation. After the Pu isotopes in the radioactive waste samples were separated from the other nuclides with an anion exchange resin, the Am isotopes were purified with a TRU resin and an anion exchange resin or a TRU resin. Activity concentrations and chemical recoveries of 241 Am purified with the TRU resin were similar to those with the TRU resin and anion exchange resin. In this study, to save on the analytical time and cost, the Am isotopes were purified with the TRU resin without using an additional anion exchange resin. After comparing the electrodeposition method with the micro-coprecipitation method, the micro-coprecipitation method was used for the alpha source preparation, because the micro-coprecipitation method is simple and more reliable for source preparation of the Pu, Am and Cm isotopes

  1. Comparison of macro-gravimetric and micro-colorimetric lipid determination methods.

    Science.gov (United States)

    Inouye, Laura S; Lotufo, Guiherme R

    2006-10-15

    In order to validate a method for lipid analysis of small tissue samples, the standard macro-gravimetric method of Bligh-Dyer (1959) [E.G. Bligh, W.J. Dyer, Can. J. Biochem. Physiol. 37 (1959) 911] and a modification of the micro-colorimetric assay developed by Van Handel (1985) [E. Van Handel, J. Am. Mosq. Control Assoc. 1 (1985) 302] were compared. No significant differences were observed for wet tissues of two species of fish. However, limited analysis of wet tissue of the amphipod, Leptocheirusplumulosus, indicated that the Bligh-Dyer gravimetric method generated higher lipid values, most likely due to the inclusion of non-lipid materials. Additionally, significant differences between the methods were observed with dry tissues, with the micro-colorimetric method consistently reporting calculated lipid values greater than as reported by the gravimetric method. This was most likely due to poor extraction of dry tissue in the standard Bligh-Dyer method, as no significant differences were found when analyzing a single composite extract. The data presented supports the conclusion that the micro-colorimetric method described in this paper is accurate, rapid, and minimizes time and solvent use.

  2. Validity of the t-plot method to assess microporosity in hierarchical micro/mesoporous materials.

    Science.gov (United States)

    Galarneau, Anne; Villemot, François; Rodriguez, Jeremy; Fajula, François; Coasne, Benoit

    2014-11-11

    The t-plot method is a well-known technique which allows determining the micro- and/or mesoporous volumes and the specific surface area of a sample by comparison with a reference adsorption isotherm of a nonporous material having the same surface chemistry. In this paper, the validity of the t-plot method is discussed in the case of hierarchical porous materials exhibiting both micro- and mesoporosities. Different hierarchical zeolites with MCM-41 type ordered mesoporosity are prepared using pseudomorphic transformation. For comparison, we also consider simple mechanical mixtures of microporous and mesoporous materials. We first show an intrinsic failure of the t-plot method; this method does not describe the fact that, for a given surface chemistry and pressure, the thickness of the film adsorbed in micropores or small mesopores (plot method to estimate the micro- and mesoporous volumes of hierarchical samples is then discussed, and an abacus is given to correct the underestimated microporous volume by the t-plot method.

  3. Hierarchical Coupling of First-Principles Molecular Dynamics with Advanced Sampling Methods.

    Science.gov (United States)

    Sevgen, Emre; Giberti, Federico; Sidky, Hythem; Whitmer, Jonathan K; Galli, Giulia; Gygi, Francois; de Pablo, Juan J

    2018-05-14

    We present a seamless coupling of a suite of codes designed to perform advanced sampling simulations, with a first-principles molecular dynamics (MD) engine. As an illustrative example, we discuss results for the free energy and potential surfaces of the alanine dipeptide obtained using both local and hybrid density functionals (DFT), and we compare them with those of a widely used classical force field, Amber99sb. In our calculations, the efficiency of first-principles MD using hybrid functionals is augmented by hierarchical sampling, where hybrid free energy calculations are initiated using estimates obtained with local functionals. We find that the free energy surfaces obtained from classical and first-principles calculations differ. Compared to DFT results, the classical force field overestimates the internal energy contribution of high free energy states, and it underestimates the entropic contribution along the entire free energy profile. Using the string method, we illustrate how these differences lead to different transition pathways connecting the metastable minima of the alanine dipeptide. In larger peptides, those differences would lead to qualitatively different results for the equilibrium structure and conformation of these molecules.

  4. Modified micro-diffusion method for 15N-enriched soil solutions

    International Nuclear Information System (INIS)

    Aigner, M.

    2000-01-01

    The preparation of solutions for determination of 15 N/ 14 N isotope ratios is described, with special reference to dilute samples. A micro-diffusion method has been simplified to be more suitable for rapid isotope-ratio determination in soil solutions collected in tensionics. Ammonia expelled during micro-diffusion is captured on acidified filter discs fixed to the caps of gas-tight vials. The discs are transferred to tin capsules for shipment to the Soil Science Unit for 15 N-enrichment determination. (author)

  5. Advanced Exploration Technologies: Micro and Nano Technologies Enabling Space Missions in the 21st Century

    Science.gov (United States)

    Krabach, Timothy

    1998-01-01

    Some of the many new and advanced exploration technologies which will enable space missions in the 21st century and specifically the Manned Mars Mission are explored in this presentation. Some of these are the system on a chip, the Computed-Tomography imaging Spectrometer, the digital camera on a chip, and other Micro Electro Mechanical Systems (MEMS) technology for space. Some of these MEMS are the silicon micromachined microgyroscope, a subliming solid micro-thruster, a micro-ion thruster, a silicon seismometer, a dewpoint microhygrometer, a micro laser doppler anemometer, and tunable diode laser (TDL) sensors. The advanced technology insertion is critical for NASA to decrease mass, volume, power and mission costs, and increase functionality, science potential and robustness.

  6. Advances in Multicompartment Mesoporous Silica Micro/Nanoparticles for Theranostic Applications.

    Science.gov (United States)

    Liu, Jian; Liu, Tingting; Pan, Jian; Liu, Shaomin; Lu, G Q Max

    2018-04-04

    Mesoporous silica nanoparticles (MSNs) are promising functional nanomaterials for a variety of biomedical applications, such as bioimaging, drug/gene delivery, and cancer therapy. This is due to their low density, low toxicity, high biocompatibility, large specific surface areas, and excellent thermal and mechanical stability. The past decade has seen rapid advances in the development of MSNs with multiple compartments. These include hierarchical porous structures and core-shell, yolk-shell, and Janus structured particles for efficient diagnosis and therapeutic applications. We review advances in this area, covering the categories of multicompartment MSNs and their synthesis methods, with an emphasis on hierarchical structures and the incorporation of multiple functions. We classify multicompartment mesoporous silica micro/nanostructures, ranging from core-shell and yolk-shell structures to Janus and raspberry-like nanoparticles, and discuss their synthesis methods. We review applications of these multicompartment MSNs, including bioimaging, targeted drug/gene delivery, chemotherapy, phototherapy, and in vitro diagnostics. We also highlight the latest trends and new opportunities. Expected final online publication date for the Annual Review of Chemical and Biomolecular Engineering Volume 9 is June 7, 2018. Please see http://www.annualreviews.org/page/journal/pubdates for revised estimates.

  7. Nondestructive Analysis of Apollo Samples by Micro-CT and Micro-XRF Analysis: A PET Style Examination

    Science.gov (United States)

    Zeigler, Ryan A.

    2014-01-01

    An integral part of any sample return mission is the initial description and classification of returned samples by the preliminary examination team (PET). The goal of a PET is to characterize and classify the returned samples, making this information available to the general research community who can then conduct more in-depth studies on the samples. A PET strives to minimize the impact their work has on the sample suite, which often limits the PET work to largely visual measurements and observations like optical microscopy. More modern techniques can also be utilized by future PET to nondestructively characterize astromaterials in a more rigorous way. Here we present our recent analyses of Apollo samples 14321 and 14305 by micro-CT and micro-XRF (respectively), assess the potential for discovery of "new" Apollo samples for scientific study, and evaluate the usefulness of these techniques in future PET efforts.

  8. X-ray micro-Tomography at the Advanced Light Source

    Science.gov (United States)

    The X-ray micro-Tomography Facility at the Advanced Light Source has been in operation since 2004. The source is a superconducting bend magnet of critical energy 10.5KeV; photon energy coverage is 8-45 KeV in monochromatic mode, and a filtered white light option yields useful photons up to 50 KeV. A...

  9. X-Ray Micro-Computed Tomography of Apollo Samples as a Curation Technique Enabling Better Research

    Science.gov (United States)

    Ziegler, R. A.; Almeida, N. V.; Sykes, D.; Smith, C. L.

    2014-01-01

    X-ray micro-computed tomography (micro-CT) is a technique that has been used to research meteorites for some time and many others], and recently it is becoming a more common tool for the curation of meteorites and Apollo samples. Micro-CT is ideally suited to the characterization of astromaterials in the curation process as it can provide textural and compositional information at a small spatial resolution rapidly, nondestructively, and without compromising the cleanliness of the samples (e.g., samples can be scanned sealed in Teflon bags). This data can then inform scientists and curators when making and processing future sample requests for meteorites and Apollo samples. Here we present some preliminary results on micro-CT scans of four Apollo regolith breccias. Methods: Portions of four Apollo samples were used in this study: 14321, 15205, 15405, and 60639. All samples were 8-10 cm in their longest dimension and approximately equant. These samples were micro-CT scanned on the Nikon HMXST 225 System at the Natural History Museum in London. Scans were made at 205-220 kV, 135-160 microamps beam current, with an effective voxel size of 21-44 microns. Results: Initial examination of the data identify a variety of mineral clasts (including sub-voxel FeNi metal grains) and lithic clasts within the regolith breccias. Textural information within some of the lithic clasts was also discernable. Of particular interest was a large basalt clast (approx.1.3 cc) found within sample 60639, which appears to have a sub-ophitic texture. Additionally, internal void space, e.g., fractures and voids, is readily identifiable. Discussion: It is clear from the preliminary data that micro-CT analyses are able to identify important "new" clasts within the Apollo breccias, and better characterize previously described clasts or igneous samples. For example, the 60639 basalt clast was previously believed to be quite small based on its approx.0.5 sq cm exposure on the surface of the main mass

  10. Reexamination of basal plane thermal conductivity of suspended graphene samples measured by electro-thermal micro-bridge methods

    Directory of Open Access Journals (Sweden)

    Insun Jo

    2015-05-01

    Full Text Available Thermal transport in suspended graphene samples has been measured in prior works and this work with the use of a suspended electro-thermal micro-bridge method. These measurement results are analyzed here to evaluate and eliminate the errors caused by the extrinsic thermal contact resistance. It is noted that the room-temperature thermal resistance measured in a recent work increases linearly with the suspended length of the single-layer graphene samples synthesized by chemical vapor deposition (CVD, and that such a feature does not reveal the failure of Fourier’s law despite the increase in the reported apparent thermal conductivity with length. The re-analyzed apparent thermal conductivity of a single-layer CVD graphene sample reaches about 1680 ± 180 W m−1 K−1 at room temperature, which is close to the highest value reported for highly oriented pyrolytic graphite. In comparison, the apparent thermal conductivity values measured for two suspended exfoliated bi-layer graphene samples are about 880 ± 60 and 730 ± 60 Wm−1K−1 at room temperature, and approach that of the natural graphite source above room temperature. However, the low-temperature thermal conductivities of these suspended graphene samples are still considerably lower than the graphite values, with the peak thermal conductivities shifted to much higher temperatures. Analysis of the thermal conductivity data reveals that the low temperature behavior is dominated by phonon scattering by polymer residue instead of by the lateral boundary.

  11. Autonomous micro-platform for multisensors with an advanced power management unit (PMU

    Directory of Open Access Journals (Sweden)

    P. Bellier

    2018-04-01

    Full Text Available In this work, we developed and characterised an autonomous micro-platform including several types of sensors, an advanced power management unit (PMU and radio frequency (RF transmission capabilities. Autonomy requires integration of an energy harvester, an energy storage device, a PMU, ultra-low-power components (including sensors and optimized software. Our choice was to use commercial off-the-shelf components with low-power consumption, low cost and compactness as selection criteria. For the multi-purpose micro-platform, we choose to include the most common sensors (such as temperature, humidity, luminosity, acceleration, etc. and to integrate them in one miniaturised autonomous device.A processing unit is embedded in the system. It allows for data acquisition from each sensor individually, simple data processing, and storing and/or wireless data transmission. Such a system can be used as stand-alone, with an internal storage in a non-volatile memory, or as a node in a wireless network, with bi-directional communication with a hub device where data can be analysed further. According to specific application requirements, system settings can be adjusted, such as the sampling rate, the resolution and the processing of the sensor data.Parallel to full autonomous functionality, the low-power design enables us to power the system by a small battery leading to a high degree of autonomy at a high sampling rate. Therefore, we also developed an alternative battery-powered version of the micro-platform that increases the range of applications. As such, the system is highly versatile and due to its reduced dimensions, it can be used nearly everywhere. Typical applications include the Internet of Things, Industry 4.0, home automation and building structural health monitoring.

  12. A minimally invasive micro sampler for quantitative sampling with an ultrahigh-aspect-ratio microneedle and a PDMS actuator.

    Science.gov (United States)

    Liu, Long; Wang, Yan; Yao, Jinyuan; Yang, Cuijun; Ding, Guifu

    2016-08-01

    This study describes a novel micro sampler consisting of an ultrahigh-aspect-ratio microneedle and a PDMS actuator. The microneedle was fabricated by a new method which introduced reshaped photoresist technology to form a flow channel inside. The microneedle includes two parts: shaft and pedestal. In this study, the shaft length is 1500 μm with a 45° taper angle on the tip and pedestal is 1000 μm. Besides, the shaft and pedestal are connected by an arc connection structure with a length of 600 μm. The microneedles have sufficient mechanical strength to insert into skin with a wide safety margin which was proved by mechanics tests. Moreover, a PDMS actuator with a chamber inside was designed and fabricated in this study. The chamber, acting as a reservoir in sampling process as well as providing power, was optimized by finite element analysis (FEA) to decrease dead volume and improve sampling precision. The micro sampler just needs finger press to activate the sampling process as well as used for quantitative micro injection to some extent. And a volume of 31.5 ± 0.8 μl blood was successfully sampled from the ear artery of a rabbit. This micro sampler is suitable for micro sampling for diagnose or therapy in biomedical field.

  13. Advanced measurement and analysis of surface textures produced by micro-machining processes

    International Nuclear Information System (INIS)

    Bordatchev, Evgueni V; Hafiz, Abdullah M K

    2014-01-01

    Surface texture of a part or a product has significant effects on its functionality, physical-mechanical properties and visual appearance. In particular for miniature products, the implication of surface quality becomes critical owing to the presence of geometrical features with micro/nano-scale dimensions. Qualitative and quantitative assessments of surface texture are carried out predominantly by profile parameters, which are often insufficient to address the contribution of constituent spatial components with varied amplitudes and wavelengths. In this context, this article presents a novel approach for advanced measurement and analysis of profile average roughness (R a ) and its spatial distribution at different wavelength intervals. The applicability of the proposed approach was verified for three different surface topographies prepared by grinding, laser micro-polishing and micro-milling processes. From the measurement and analysis results, R a (λ) spatial distribution was found to be an effective measure of revealing the contributions of various spatial components within specific wavelength intervals towards formation of the entire surface profile. In addition, the approach was extended to the measurement and analysis of areal average roughness S a (λ) spatial distribution within different wavelength intervals. Besides, the proposed method was demonstrated to be a useful technique in developing a functional correlation between a manufacturing process and its corresponding surface profile. (paper)

  14. Solid phase micro-extraction in environmental atmosphere

    International Nuclear Information System (INIS)

    Tao Ping; Wei Lifan; Tan Yun

    2002-01-01

    Solid phase micro-extraction (SPME) is an advanced technique of sample pretreatment in environmental atmosphere analysis, i.e., a sampling method of extracting volatile organic compounds from environmental gas. According to the primary survey on the theory and application of SPME, a suitable extraction tip, i.e., a coated fused silica fiber, is selected to construct a SPME apparatus. This SPME apparatus is used to extract volatile organic compounds from environmental atmosphere and a qualitative detection is conducted in gas chromatography-mass spectrometer system. Good experimental results are obtained

  15. Structure of catalase determined by MicroED

    Science.gov (United States)

    Nannenga, Brent L; Shi, Dan; Hattne, Johan; Reyes, Francis E; Gonen, Tamir

    2014-01-01

    MicroED is a recently developed method that uses electron diffraction for structure determination from very small three-dimensional crystals of biological material. Previously we used a series of still diffraction patterns to determine the structure of lysozyme at 2.9 Å resolution with MicroED (Shi et al., 2013). Here we present the structure of bovine liver catalase determined from a single crystal at 3.2 Å resolution by MicroED. The data were collected by continuous rotation of the sample under constant exposure and were processed and refined using standard programs for X-ray crystallography. The ability of MicroED to determine the structure of bovine liver catalase, a protein that has long resisted atomic analysis by traditional electron crystallography, demonstrates the potential of this method for structure determination. DOI: http://dx.doi.org/10.7554/eLife.03600.001 PMID:25303172

  16. Micro Expression Recognition Using the Eulerian Video Magnification Method

    Directory of Open Access Journals (Sweden)

    Elham Zarezadeh

    2016-08-01

    Full Text Available In this paper we propose a new approach for facial micro expressions recognition. For this purpose the Eulerian Video Magnification (EVM method is used to retrieve the subtle motions of the face. The results of this method are obtained as in the magnified images sequence. In this study the numerical tests are performed on two databases: Spontaneous Micro expression (SMIC and Category and Sourcing Managers Executive (CASME. We evaluate our proposed method in two phases using the eigenface method. In phase 1 we recognize the type of a micro expression, for example emotional versus unemotional in SMIC database. Phase 2 classifies the recognized micro expression as negative versus positive in SMIC database and happiness versus disgust in CASME database. The results show that the eigenface method by the EVM method for the retrieval of subtle motions of the face increases the performance of micro expression recognition. Moreover, the proposed approach is more accurate and promising than the previous works in micro expressions recognition.

  17. Advanced pressure tube sampling tools

    International Nuclear Information System (INIS)

    Wittich, K.C.; King, J.M.

    2002-01-01

    Deuterium concentration is an important parameter that must be assessed to evaluate the Fitness for service of CANDU pressure tubes. In-reactor pressure tube sampling allows accurate deuterium concentration assessment to be made without the expenses associated with fuel channel removal. This technology, which AECL has developed over the past fifteen years, has become the standard method for deuterium concentration assessment. AECL is developing a multi-head tool that would reduce in-reactor handling overhead by allowing one tool to sequentially sample at all four axial pressure tube locations before removal from the reactor. Four sets of independent cutting heads, like those on the existing sampling tools, facilitate this incorporating proven technology demonstrated in over 1400 in-reactor samples taken to date. The multi-head tool is delivered by AECL's Advanced Delivery Machine or other similar delivery machines. Further, AECL has developed an automated sample handling system that receives and processes the tool once out of the reactor. This system retrieves samples from the tool, dries, weighs and places them in labelled vials which are then directed into shielded shipping flasks. The multi-head wet sampling tool and the automated sample handling system are based on proven technology and offer continued savings and dose reduction to utilities in a competitive electricity market. (author)

  18. Advancing three-dimensional MEMS by complimentary laser micro manufacturing

    Science.gov (United States)

    Palmer, Jeremy A.; Williams, John D.; Lemp, Tom; Lehecka, Tom M.; Medina, Francisco; Wicker, Ryan B.

    2006-01-01

    This paper describes improvements that enable engineers to create three-dimensional MEMS in a variety of materials. It also provides a means for selectively adding three-dimensional, high aspect ratio features to pre-existing PMMA micro molds for subsequent LIGA processing. This complimentary method involves in situ construction of three-dimensional micro molds in a stand-alone configuration or directly adjacent to features formed by x-ray lithography. Three-dimensional micro molds are created by micro stereolithography (MSL), an additive rapid prototyping technology. Alternatively, three-dimensional features may be added by direct femtosecond laser micro machining. Parameters for optimal femtosecond laser micro machining of PMMA at 800 nanometers are presented. The technical discussion also includes strategies for enhancements in the context of material selection and post-process surface finish. This approach may lead to practical, cost-effective 3-D MEMS with the surface finish and throughput advantages of x-ray lithography. Accurate three-dimensional metal microstructures are demonstrated. Challenges remain in process planning for micro stereolithography and development of buried features following femtosecond laser micro machining.

  19. Analysis of the enamel hypoplasia using micro-CT scanner versus classical method.

    Science.gov (United States)

    Marchewka, Justyna; Skrzat, Janusz; Wróbel, Andrzej

    2014-01-01

    This article demonstrates the use of micro-CT scanning of the teeth surface for recognizing and evaluating severity of the enamel hypoplasia. To test capabilities of the microtomography versus classical method of evaluation hypoplastic defects of the enamel we selected two human teeth (C, M(2)) showing different types of enamel hypoplasia: linear, pits, and groove. Examined samples derive from archeological material dated on XVII-XVIII AD and excavated in Poland. In the current study we proved that micro-CT scanning is a powerful technique not only for imaging all kinds of the enamel hypoplasia but also allows to perform accurate measurements of the enamel defects. We figure out that contrary to the classical method of scoring enamel defects, the micro-computed tomography yields adequate data which serve for estimating the length of stress episode and length of interval between them.

  20. Micro-PIXE on thin plant tissue samples in frozen hydrated state: A novel addition to JSI nuclear microprobe

    International Nuclear Information System (INIS)

    Vavpetič, P.; Pelicon, P.; Vogel-Mikuš, K.; Grlj, N.; Pongrac, P.; Jeromel, L.; Ogrinc, N.; Regvar, M.

    2013-01-01

    Recently we completed a construction of a cryostat at Jožef Stefan Institute (JSI) nuclear microprobe enabling us to analyze various types of biological samples in frozen hydrated state using micro-PIXE/STIM/RBS. Sample load-lock system was added to our existing setup to enable us to quickly insert a sample holder with frozen hydrated tissue samples onto a cold goniometer head cooled with liquid nitrogen inside the measuring chamber. Cryotome-cut slices of frozen hydrated plant samples were mounted between two thin silicon nitride foils and then attached to the sample holder. Sufficient thermal contact between silicon nitride foils and sample holder must be achieved, as well as between the sample holder and the cold goniometer head inside the measuring chamber to prevent melting of the samples. Matrix composition of frozen hydrated tissue is consisted mostly of ice. Thinning of the sample as well as water evaporation during high vacuum and proton beam exposure was inspected by the measurements with RBS and STIM method simultaneously with micro-PIXE. For first measuring attempts a standard micro-PIXE configuration for tissue mapping was used with proton beam cross section of 1.2 × 1.2 μm 2 and a beam current of 100 pA. The temperature of the cold goniometer head was kept below 130 K throughout the entire proton beam exposure. First measurements of thin plant tissue samples in frozen hydrated state show minute sample degradation during the 10 h period of micro-PIXE measurements

  1. Direct PCR amplification of DNA from human bloodstains, saliva, and touch samples collected with microFLOQ® swabs.

    Science.gov (United States)

    Ambers, Angie; Wiley, Rachel; Novroski, Nicole; Budowle, Bruce

    2018-01-01

    Previous studies have shown that nylon flocked swabs outperform traditional fiber swabs in DNA recovery due to their innovative design and lack of internal absorbent core to entrap cellular materials. The microFLOQ ® Direct swab, a miniaturized version of the 4N6 FLOQSwab ® , has a small swab head that is treated with a lysing agent which allows for direct amplification and DNA profiling from sample collection to final result in less than two hours. Additionally, the microFLOQ ® system subsamples only a minute portion of a stain and preserves the vast majority of the sample for subsequent testing or re-analysis, if desired. The efficacy of direct amplification of DNA from dilute bloodstains, saliva stains, and touch samples was evaluated using microFLOQ ® Direct swabs and the GlobalFiler™ Express system. Comparisons were made to traditional methods to assess the robustness of this alternate workflow. Controlled studies with 1:19 and 1:99 dilutions of bloodstains and saliva stains consistently yielded higher STR peak heights than standard methods with 1ng input DNA from the same samples. Touch samples from common items yielded single source and mixed profiles that were consistent with primary users of the objects. With this novel methodology/workflow, no sample loss occurs and therefore more template DNA is available during amplification. This approach may have important implications for analysis of low quantity and/or degraded samples that plague forensic casework. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  2. A novel bonding method for large scale poly(methyl methacrylate) micro- and nanofluidic chip fabrication

    Science.gov (United States)

    Qu, Xingtian; Li, Jinlai; Yin, Zhifu

    2018-04-01

    Micro- and nanofluidic chips are becoming increasing significance for biological and medical applications. Future advances in micro- and nanofluidics and its utilization in commercial applications depend on the development and fabrication of low cost and high fidelity large scale plastic micro- and nanofluidic chips. However, the majority of the present fabrication methods suffer from a low bonding rate of the chip during thermal bonding process due to air trapping between the substrate and the cover plate. In the present work, a novel bonding technique based on Ar plasma and water treatment was proposed to fully bond the large scale micro- and nanofluidic chips. The influence of Ar plasma parameters on the water contact angle and the effect of bonding conditions on the bonding rate and the bonding strength of the chip were studied. The fluorescence tests demonstrate that the 5 × 5 cm2 poly(methyl methacrylate) chip with 180 nm wide and 180 nm deep nanochannels can be fabricated without any block and leakage by our newly developed method.

  3. Advanced biomaterial strategies to transplant preformed micro-tissue engineered neural networks into the brain

    Science.gov (United States)

    Harris, J. P.; Struzyna, L. A.; Murphy, P. L.; Adewole, D. O.; Kuo, E.; Cullen, D. K.

    2016-02-01

    Objective. Connectome disruption is a hallmark of many neurological diseases and trauma with no current strategies to restore lost long-distance axonal pathways in the brain. We are creating transplantable micro-tissue engineered neural networks (micro-TENNs), which are preformed constructs consisting of embedded neurons and long axonal tracts to integrate with the nervous system to physically reconstitute lost axonal pathways. Approach. We advanced micro-tissue engineering techniques to generate micro-TENNs consisting of discrete populations of mature primary cerebral cortical neurons spanned by long axonal fascicles encased in miniature hydrogel micro-columns. Further, we improved the biomaterial encasement scheme by adding a thin layer of low viscosity carboxymethylcellulose (CMC) to enable needle-less insertion and rapid softening for mechanical similarity with brain tissue. Main results. The engineered architecture of cortical micro-TENNs facilitated robust neuronal viability and axonal cytoarchitecture to at least 22 days in vitro. Micro-TENNs displayed discrete neuronal populations spanned by long axonal fasciculation throughout the core, thus mimicking the general systems-level anatomy of gray matter—white matter in the brain. Additionally, micro-columns with thin CMC-coating upon mild dehydration were able to withstand a force of 893 ± 457 mN before buckling, whereas a solid agarose cylinder of similar dimensions was predicted to withstand less than 150 μN of force. This thin CMC coating increased the stiffness by three orders of magnitude, enabling needle-less insertion into brain while significantly reducing the footprint of previous needle-based delivery methods to minimize insertion trauma. Significance. Our novel micro-TENNs are the first strategy designed for minimally invasive implantation to facilitate nervous system repair by simultaneously providing neuronal replacement and physical reconstruction of long-distance axon pathways in the brain

  4. "One-sample concept" micro-combinatory for high throughput TEM of binary films.

    Science.gov (United States)

    Sáfrán, György

    2018-04-01

    Phases of thin films may remarkably differ from that of bulk. Unlike to the comprehensive data files of Binary Phase Diagrams [1] available for bulk, complete phase maps for thin binary layers do not exist. This is due to both the diverse metastable, non-equilibrium or instable phases feasible in thin films and the required volume of characterization work with analytical techniques like TEM, SAED and EDS. The aim of the present work was to develop a method that remarkably facilitates the TEM study of the diverse binary phases of thin films, or the creation of phase maps. A micro-combinatorial method was worked out that enables both preparation and study of a gradient two-component film within a single TEM specimen. For a demonstration of the technique thin Mn x Al 1- x binary samples with evolving concentration from x = 0 to x = 1 have been prepared so that the transition from pure Mn to pure Al covers a 1.5 mm long track within the 3 mm diameter TEM grid. The proposed method enables the preparation and study of thin combinatorial samples including all feasible phases as a function of composition or other deposition parameters. Contrary to known "combinatorial chemistry", in which a series of different samples are deposited in one run, and investigated, one at a time, the present micro-combinatorial method produces a single specimen condensing a complete library of a binary system that can be studied, efficiently, within a single TEM session. That provides extremely high throughput for TEM characterization of composition-dependent phases, exploration of new materials, or the construction of phase diagrams of binary films. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Research of Dielectric Breakdown Micro fluidic Sampling Chip

    International Nuclear Information System (INIS)

    Jiang, F.; Lei, Y.; Yu, J.

    2013-01-01

    Micro fluidic chip is mainly driven electrically by external electrode and array electrode, but there are certain disadvantages in both of ways, which affect the promotion and application of micro fluidic technology. This paper discusses a scheme that uses the conductive solution in a microchannel made by PDMS, replacing electrodes and the way of dielectric breakdown to achieve microfluidic chip driver. It could reduce the driving voltage and simplify the chip production process. To prove the feasibility of this method, we produced a micro fluidic chip used in PDMS material with the lithography technology and experimented it. The results showed that using the dielectric breakdown to achieve microfluidic chip driver is feasible, and it has certain application prospect.

  6. Domain Regeneration for Cross-Database Micro-Expression Recognition

    Science.gov (United States)

    Zong, Yuan; Zheng, Wenming; Huang, Xiaohua; Shi, Jingang; Cui, Zhen; Zhao, Guoying

    2018-05-01

    In this paper, we investigate the cross-database micro-expression recognition problem, where the training and testing samples are from two different micro-expression databases. Under this setting, the training and testing samples would have different feature distributions and hence the performance of most existing micro-expression recognition methods may decrease greatly. To solve this problem, we propose a simple yet effective method called Target Sample Re-Generator (TSRG) in this paper. By using TSRG, we are able to re-generate the samples from target micro-expression database and the re-generated target samples would share same or similar feature distributions with the original source samples. For this reason, we can then use the classifier learned based on the labeled source samples to accurately predict the micro-expression categories of the unlabeled target samples. To evaluate the performance of the proposed TSRG method, extensive cross-database micro-expression recognition experiments designed based on SMIC and CASME II databases are conducted. Compared with recent state-of-the-art cross-database emotion recognition methods, the proposed TSRG achieves more promising results.

  7. Micro Machining Enhances Precision Fabrication

    Science.gov (United States)

    2007-01-01

    Advanced thermal systems developed for the Space Station Freedom project are now in use on the International Space Station. These thermal systems employ evaporative ammonia as their coolant, and though they employ the same series of chemical reactions as terrestrial refrigerators, the space-bound coolers are significantly smaller. Two Small Business Innovation Research (SBIR) contracts between Creare Inc. of Hanover, NH and Johnson Space Center developed an ammonia evaporator for thermal management systems aboard Freedom. The principal investigator for Creare Inc., formed Mikros Technologies Inc. to commercialize the work. Mikros Technologies then developed an advanced form of micro-electrical discharge machining (micro-EDM) to make tiny holes in the ammonia evaporator. Mikros Technologies has had great success applying this method to the fabrication of micro-nozzle array systems for industrial ink jet printing systems. The company is currently the world leader in fabrication of stainless steel micro-nozzles for this market, and in 2001 the company was awarded two SBIR research contracts from Goddard Space Flight Center to advance micro-fabrication and high-performance thermal management technologies.

  8. Recent advances in design and fabrication of on-chip micro-supercapacitors

    Science.gov (United States)

    Beidaghi, Majid; Wang, Chunlei

    2012-06-01

    Recent development in miniaturized electronic devices has increased the demand for power sources that are sufficiently compact and can potentially be integrated on a chip with other electronic components. Miniaturized electrochemical capacitors (EC) or micro-supercapacitors have great potential to complement or replace batteries and electrolytic capacitors in a variety of applications. Recently, we have developed several types of micro-supercapacitors with different structural designs and active materials. Carbon-Microelectromechanical Systems (C-MEMS) with three dimensional (3D) interdigital structures are employed both as electrode material for electric double layer capacitor (EDLC) or as three dimensional (3D) current collectors of pseudo-capacitive materials. More recently, we have also developed microsupercapacitor based on hybrid graphene and carbon nanotube interdigital structures. In this paper, the recent advances in design and fabrication of on-chip micro-supercapacitors are reviewed.

  9. Micro-Lid For Sealing Sample Reservoirs of micro-Extraction Systems

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to develop a proof-of-concept micro-Lid (µLid) to tightly seal a micro-sampler or micro-extraction system. Fabrication of µLid would be conducted in the...

  10. Non-invasive in-situ investigations versus micro-sampling: a comparative study on a Renoirs painting

    International Nuclear Information System (INIS)

    Miliani, C.; Sgamellotti, A.; Universita degli Studi di Perugia . Centro di Eccellenza SMAArt; Scientific Methodologies applied to Archaeology and Art)

    2007-01-01

    In this paper, a multi-technique in-situ non-invasive approach has been followed for the study of the materials used for a painting by Pierre-Auguste Renoir, ''A woman at her toilette''. The study was carried out using five portable spectroscopic techniques, namely X-ray fluorescence, mid-infrared reflectance spectroscopy, near infrared reflectance spectroscopy, and UV-Vis spectroscopy in absorption and emission. The painting was selected as a case study because it was examined in advance of the current investigation using conventional micro-sampling techniques. This provided the opportunity to evaluate potential and limitations of the non-invasive approach to the complex case of the modern painting. (orig.)

  11. Plasma assisted nitriding for micro-texturing onto martensitic stainless steels*

    OpenAIRE

    Katoh Takahisa; Aizawa Tatsuhiko; Yamaguchi Tetsuya

    2015-01-01

    Micro-texturing method has grown up to be one of the most promising procedures to form micro-lines, micro-dots and micro-grooves onto the mold-die materials and to duplicate these micro-patterns onto metallic or polymer sheets via stamping or injection molding. This related application requires for large-area, fine micro-texturing onto the martensitic stainless steel mold-die materials. A new method other than laser-machining, micro-milling or micro-EDM is awaited for further advancement of t...

  12. Advanced Micro Turbine System (AMTS) -C200 Micro Turbine -Ultra-Low Emissions Micro Turbine

    Energy Technology Data Exchange (ETDEWEB)

    Capstone Turbine Corporation

    2007-12-31

    In September 2000 Capstone Turbine Corporation commenced work on a US Department of Energy contract to develop and improve advanced microturbines for power generation with high electrical efficiency and reduced pollutants. The Advanced MicroTurbine System (AMTS) program focused on: (1) The development and implementation of technology for a 200 kWe scale high efficiency microturbine system (2) The development and implementation of a 65 kWe microturbine which meets California Air Resources Board (CARB) emissions standards effective in 2007. Both of these objectives were achieved in the course of the AMTS program. At its conclusion prototype C200 Microturbines had been designed, assembled and successfully completed field demonstration. C65 Microturbines operating on natural, digester and landfill gas were also developed and successfully tested to demonstrate compliance with CARB 2007 Fossil Fuel Emissions Standards for NOx, CO and VOC emissions. The C65 Microturbine subsequently received approval from CARB under Executive Order DG-018 and was approved for sale in California. The United Technologies Research Center worked in parallel to successfully execute a RD&D program to demonstrate the viability of a low emissions AMS which integrated a high-performing microturbine with Organic Rankine Cycle systems. These results are documented in AMS Final Report DOE/CH/11060-1 dated March 26, 2007.

  13. Synthesis of micro- and nanodiamonds by the method of oxy- acetylene combustion flame

    International Nuclear Information System (INIS)

    Sabitov, S; Medyanova, B; Partizan, G; Koshanova, A; Mansurova, M; Lesbayev, B; Mansurov, B; Merkibayev, Ye

    2016-01-01

    This work presents the results of experiments on synthesis of micro- and nanodiamonds by the method of oxy-acetylene torch on the surface of pre-deposited copper thin films. The influence of the thickness of the buffer copper film and the concentration ratio of oxygen and acetylene on the structure formation of the deposited samples was investigated during performed experiments. Studies by Raman scattering and scanning electron microscopy showed that the synthesis of micro- and nano-diamonds occurs under certain experimental conditions. (paper)

  14. ArF photo resist pattern sample preparation method using FIB without protective coating

    Science.gov (United States)

    Okushima, Hirohisa; Onozuka, Toshihiko; Kuroda, Yasushi; Yaguchi, Toshie; Umemura, Kaoru; Tamochi, Ryuichiro; Watanabe, Kenji; Hasegawa, Norio; Kawata, Isao; Rijpers, Bart

    2006-03-01

    This paper presents a novel method of FIB (FIB: focused ion beam) sample preparation to accurately evaluate critical dimensions and profiles of ArF photo resist patterns without the use of a protective coating on the photo resist. In order to accomplish this, the FIB micro-sampling method that is one of effective FIB milling and fabrication method was employed. First a Si cap is picked up from a silicon wafer and fixed to ArF photo resist patterns to protect against ion beam irradiation. Then, a micro-sample, a piece of Si-capped ArF photo resist, was extracted from the bulk ArF photo resist. In this procedure, this silicon cap always protects ArF photo resist patterns against ion beam irradiation. For the next step, the micro-sample is fixed to a needle stub of the FIB-STEM (STEM: scanning transmission electron microscopy) compatible rotation holder. This sample on the needle stub was rotated 180 degrees and milled from the side of Si substrate. Lastly, the sample is milled to the thickness of 2μm. In this process, the ion beam is irradiating from the silicon substrate side to minimize the ion beam irradiation damages on the ArF photo resist patterns. EDX (EDX: Energy dispersive X-ray spectroscopy) analysis proved that no gallium ions were detected on the surface of the ArF photo resist patterns. The feasibility of high accelerating voltage observation of STEM to observe line edge roughness of a thick sample like 2μm without shrinkage has been demonstrated.

  15. An Interdisciplinary Method for the Visualization of Novel High-Resolution Precision Photography and Micro-XCT Data Sets of NASA's Apollo Lunar Samples and Antarctic Meteorite Samples to Create Combined Research-Grade 3D Virtual Samples for the Benefit of Astromaterials Collections Conservation, Curation, Scientific Research and Education

    Science.gov (United States)

    Blumenfeld, E. H.; Evans, C. A.; Oshel, E. R.; Liddle, D. A.; Beaulieu, K.; Zeigler, R. A.; Hanna, R. D.; Ketcham, R. A.

    2016-01-01

    New technologies make possible the advancement of documentation and visualization practices that can enhance conservation and curation protocols for NASA's Astromaterials Collections. With increasing demands for accessibility to updated comprehensive data, and with new sample return missions on the horizon, it is of primary importance to develop new standards for contemporary documentation and visualization methodologies. Our interdisciplinary team has expertise in the fields of heritage conservation practices, professional photography, photogrammetry, imaging science, application engineering, data curation, geoscience, and astromaterials curation. Our objective is to create virtual 3D reconstructions of Apollo Lunar and Antarctic Meteorite samples that are a fusion of two state-of-the-art data sets: the interior view of the sample by collecting Micro-XCT data and the exterior view of the sample by collecting high-resolution precision photography data. These new data provide researchers an information-rich visualization of both compositional and textural information prior to any physical sub-sampling. Since January 2013 we have developed a process that resulted in the successful creation of the first image-based 3D reconstruction of an Apollo Lunar Sample correlated to a 3D reconstruction of the same sample's Micro- XCT data, illustrating that this technique is both operationally possible and functionally beneficial. In May of 2016 we began a 3-year research period during which we aim to produce Virtual Astromaterials Samples for 60 high-priority Apollo Lunar and Antarctic Meteorite samples and serve them on NASA's Astromaterials Acquisition and Curation website. Our research demonstrates that research-grade Virtual Astromaterials Samples are beneficial in preserving for posterity a precise 3D reconstruction of the sample prior to sub-sampling, which greatly improves documentation practices, provides unique and novel visualization of the sample's interior and

  16. Micro/Nano-scale Strain Distribution Measurement from Sampling Moiré Fringes.

    Science.gov (United States)

    Wang, Qinghua; Ri, Shien; Tsuda, Hiroshi

    2017-05-23

    This work describes the measurement procedure and principles of a sampling moiré technique for full-field micro/nano-scale deformation measurements. The developed technique can be performed in two ways: using the reconstructed multiplication moiré method or the spatial phase-shifting sampling moiré method. When the specimen grid pitch is around 2 pixels, 2-pixel sampling moiré fringes are generated to reconstruct a multiplication moiré pattern for a deformation measurement. Both the displacement and strain sensitivities are twice as high as in the traditional scanning moiré method in the same wide field of view. When the specimen grid pitch is around or greater than 3 pixels, multi-pixel sampling moiré fringes are generated, and a spatial phase-shifting technique is combined for a full-field deformation measurement. The strain measurement accuracy is significantly improved, and automatic batch measurement is easily achievable. Both methods can measure the two-dimensional (2D) strain distributions from a single-shot grid image without rotating the specimen or scanning lines, as in traditional moiré techniques. As examples, the 2D displacement and strain distributions, including the shear strains of two carbon fiber-reinforced plastic specimens, were measured in three-point bending tests. The proposed technique is expected to play an important role in the non-destructive quantitative evaluations of mechanical properties, crack occurrences, and residual stresses of a variety of materials.

  17. High precision micro-scale Hall Effect characterization method using in-line micro four-point probes

    DEFF Research Database (Denmark)

    Petersen, Dirch Hjorth; Hansen, Ole; Lin, Rong

    2008-01-01

    Accurate characterization of ultra shallow junctions (USJ) is important in order to understand the principles of junction formation and to develop the appropriate implant and annealing technologies. We investigate the capabilities of a new micro-scale Hall effect measurement method where Hall...... effect is measured with collinear micro four-point probes (M4PP). We derive the sensitivity to electrode position errors and describe a position error suppression method to enable rapid reliable Hall effect measurements with just two measurement points. We show with both Monte Carlo simulations...... and experimental measurements, that the repeatability of a micro-scale Hall effect measurement is better than 1 %. We demonstrate the ability to spatially resolve Hall effect on micro-scale by characterization of an USJ with a single laser stripe anneal. The micro sheet resistance variations resulting from...

  18. Micro-PIXE evaluation of radioactive cesium transfer in contaminated soil samples

    International Nuclear Information System (INIS)

    Fujishiro, F.; Ishii, K.; Matsuyama, S.; Arai, H.; Ishizaki, A.; Osada, N.; Sugai, H.; Kusano, K.; Nozawa, Y.; Yamauchi, S.; Karahashi, M.; Oshikawa, S.; Kikuchi, K.; Koshio, S.; Watanabe, K.; Suzuki, Y.

    2014-01-01

    Highlights: • There are radioactively contaminated soils having a radioactive cesium transfer of 0.01. • Micro-PIXE analysis has revealed an existence of phosphorus in a contaminated soil. • Radioactive cesium captured by phosphorus compound would be due to radioactive transfer. -- Abstract: Micro-PIXE analysis has been performed on two soil samples with high cesium activity concentrations. These soil samples were contaminated by fallout from the accident at Fukushima Daiichi Nuclear Power Plant. One exhibits a radioactive cesium transfer of ∼0.01, and the other shows a radioactive cesium transfer of less than 0.001, even though both samples have high cesium activity concentrations exceeding 10,000 Bq/kg. X-ray spectra and elemental images of the soil samples revealed the presence of chlorine, which can react with cesium to produce an inorganic soluble compound, and phosphorus-containing cesium-capturable organic compounds

  19. Micro-NRA and micro-3HIXE with He-3 microbeam on samples exposed in ASDEX Upgrade and Pilot-PSI machines

    NARCIS (Netherlands)

    Kelemen, M.; Zaloznik, A.; Vavpetic, P.; Pecovnik, M.; Pelicon, P.; Hakola, A.; Lahtinen, A.; Karhunen, J.; Piip, K.; van der Meiden, H. J.; Paris, P.; Laan, M.; Krieger, K.; Oberkofler, M.; Markelj, S.; ASDEX Upgrade team,

    2017-01-01

    Micro nuclear reaction analysis (micro-NRA) exploiting the nuclear reaction D(He-3,p)He-4 was used for post-mortem analyses of special marker samples, exposed to deuterium plasma inside ASDEX Upgrade (AUG) tokamak and to the deuterium plasma jet in the Pilot-PSI linear plasma gun. Lateral

  20. Quantitative magnetic resonance micro-imaging methods for pharmaceutical research.

    Science.gov (United States)

    Mantle, M D

    2011-09-30

    The use of magnetic resonance imaging (MRI) as a tool in pharmaceutical research is now well established and the current literature covers a multitude of different pharmaceutically relevant research areas. This review focuses on the use of quantitative magnetic resonance micro-imaging techniques and how they have been exploited to extract information that is of direct relevance to the pharmaceutical industry. The article is divided into two main areas. The first half outlines the theoretical aspects of magnetic resonance and deals with basic magnetic resonance theory, the effects of nuclear spin-lattice (T(1)), spin-spin (T(2)) relaxation and molecular diffusion upon image quantitation, and discusses the applications of rapid magnetic resonance imaging techniques. In addition to the theory, the review aims to provide some practical guidelines for the pharmaceutical researcher with an interest in MRI as to which MRI pulse sequences/protocols should be used and when. The second half of the article reviews the recent advances and developments that have appeared in the literature concerning the use of quantitative micro-imaging methods to pharmaceutically relevant research. Copyright © 2010 Elsevier B.V. All rights reserved.

  1. Advanced Multilevel Monte Carlo Methods

    KAUST Repository

    Jasra, Ajay

    2017-04-24

    This article reviews the application of advanced Monte Carlo techniques in the context of Multilevel Monte Carlo (MLMC). MLMC is a strategy employed to compute expectations which can be biased in some sense, for instance, by using the discretization of a associated probability law. The MLMC approach works with a hierarchy of biased approximations which become progressively more accurate and more expensive. Using a telescoping representation of the most accurate approximation, the method is able to reduce the computational cost for a given level of error versus i.i.d. sampling from this latter approximation. All of these ideas originated for cases where exact sampling from couples in the hierarchy is possible. This article considers the case where such exact sampling is not currently possible. We consider Markov chain Monte Carlo and sequential Monte Carlo methods which have been introduced in the literature and we describe different strategies which facilitate the application of MLMC within these methods.

  2. Advanced Multilevel Monte Carlo Methods

    KAUST Repository

    Jasra, Ajay; Law, Kody; Suciu, Carina

    2017-01-01

    This article reviews the application of advanced Monte Carlo techniques in the context of Multilevel Monte Carlo (MLMC). MLMC is a strategy employed to compute expectations which can be biased in some sense, for instance, by using the discretization of a associated probability law. The MLMC approach works with a hierarchy of biased approximations which become progressively more accurate and more expensive. Using a telescoping representation of the most accurate approximation, the method is able to reduce the computational cost for a given level of error versus i.i.d. sampling from this latter approximation. All of these ideas originated for cases where exact sampling from couples in the hierarchy is possible. This article considers the case where such exact sampling is not currently possible. We consider Markov chain Monte Carlo and sequential Monte Carlo methods which have been introduced in the literature and we describe different strategies which facilitate the application of MLMC within these methods.

  3. Cytokinesis-block micronucleus method in micro-blood cultures

    International Nuclear Information System (INIS)

    Liu Jinwen; Wang Lianzhi; Yang Cangzhen; Yao Yanyu

    1991-01-01

    This paper reports the cytokinesis-block micronucleus method in micro-blood cultures. The observations on detection induced micronuclei of different doses of 60 Co γ-rays irradiation and spontaneous micronucleus of different ages were performed with CB method in comporison with conventional micronucleus (CM) method. The results showed that with direct peripheral micro-blood cultures the cytoknesis-block micronuclei is also obtained. Using CB method, the micronuclei fequency of different ages was linear relationship, Y = 1.62 + 0.74 D, the spontaneous micronuclei frequency of different ages was 4.14%, the induced micronuclei also was a linear relationship, Y = 6.01 + 0.692 D. Using CM method, it showed that the induced micronuclei was a linear relationship, Y = 0.486 D - 1.968, but there is no significant difference between the micronuclei frequency of different ages. Comparison with CM and direct blood smear methods confirmed that the cytokinesis-block method of micro-blood cultures is more sensitive and precise

  4. Micro-radiography of biological samples with medical contrast agents

    International Nuclear Information System (INIS)

    Dammer, J.; Weyda, F.; Benes, J.; Sopko, V.; Gelbic, I.

    2013-01-01

    Micro-radiography is an imaging technique that uses X-rays to study the internal structures of objects. This fast and easy imaging tool is based on differential X-ray attenuation by various tissues and structures within biological samples. The experimental setup described is based on the semiconductor pixel X-ray detector Medipix2 and X-ray micro-focus tube. Our micro-radiographic system has been recently used not only for the examination of internal structures of various arthropods and other biological objects but also for tracing some processes in selected model species (we used living larvae of mosquito Culex quinquefasciatus). Low concentrations of iodine, lanthanum or gold particles were used as a tracer (contrast agent). Such contrast agents increase the absorption of X-rays and allow a better visibility of internal structures of model organisms (especially the various cavities, pores, etc.). In addition, the movement of tracers in selected timing experiments demonstrates some physiological functions of digestive and excretory system

  5. Micro-radiography of biological samples with medical contrast agents

    Energy Technology Data Exchange (ETDEWEB)

    Dammer, J., E-mail: jiri.dammer@lf1.cuni.cz [Charles University in Prague, First Faculty of Medicine, Salmovská 1, 120 00 Prague 2 (Czech Republic); Hospital Na Bulovce, Department of Radiological Physics, Budinova 2, 180 81 Prague 8 (Czech Republic); Institute of Experimental and Applied Physics, Czech Technical University in Prague, Horska 3a/22, 128 00 Prague 2 (Czech Republic); Weyda, F. [Faculty of Science, University of South Bohemia, Branisovska 31, 370 05 Ceske Budejovice (Czech Republic); Benes, J. [Charles University in Prague, First Faculty of Medicine, Salmovská 1, 120 00 Prague 2 (Czech Republic); Sopko, V. [Hospital Na Bulovce, Department of Radiological Physics, Budinova 2, 180 81 Prague 8 (Czech Republic); Institute of Experimental and Applied Physics, Czech Technical University in Prague, Horska 3a/22, 128 00 Prague 2 (Czech Republic); Gelbic, I. [Biology Centre, AS CR, Institute of Entomology, Department of Biochemistry and Physiology, Branisovska 31, CZ-37005 Ceske Budejovice (Czech Republic)

    2013-12-01

    Micro-radiography is an imaging technique that uses X-rays to study the internal structures of objects. This fast and easy imaging tool is based on differential X-ray attenuation by various tissues and structures within biological samples. The experimental setup described is based on the semiconductor pixel X-ray detector Medipix2 and X-ray micro-focus tube. Our micro-radiographic system has been recently used not only for the examination of internal structures of various arthropods and other biological objects but also for tracing some processes in selected model species (we used living larvae of mosquito Culex quinquefasciatus). Low concentrations of iodine, lanthanum or gold particles were used as a tracer (contrast agent). Such contrast agents increase the absorption of X-rays and allow a better visibility of internal structures of model organisms (especially the various cavities, pores, etc.). In addition, the movement of tracers in selected timing experiments demonstrates some physiological functions of digestive and excretory system.

  6. Network-based ranking methods for prediction of novel disease associated microRNAs.

    Science.gov (United States)

    Le, Duc-Hau

    2015-10-01

    Many studies have shown roles of microRNAs on human disease and a number of computational methods have been proposed to predict such associations by ranking candidate microRNAs according to their relevance to a disease. Among them, machine learning-based methods usually have a limitation in specifying non-disease microRNAs as negative training samples. Meanwhile, network-based methods are becoming dominant since they well exploit a "disease module" principle in microRNA functional similarity networks. Of which, random walk with restart (RWR) algorithm-based method is currently state-of-the-art. The use of this algorithm was inspired from its success in predicting disease gene because the "disease module" principle also exists in protein interaction networks. Besides, many algorithms designed for webpage ranking have been successfully applied in ranking disease candidate genes because web networks share topological properties with protein interaction networks. However, these algorithms have not yet been utilized for disease microRNA prediction. We constructed microRNA functional similarity networks based on shared targets of microRNAs, and then we integrated them with a microRNA functional synergistic network, which was recently identified. After analyzing topological properties of these networks, in addition to RWR, we assessed the performance of (i) PRINCE (PRIoritizatioN and Complex Elucidation), which was proposed for disease gene prediction; (ii) PageRank with Priors (PRP) and K-Step Markov (KSM), which were used for studying web networks; and (iii) a neighborhood-based algorithm. Analyses on topological properties showed that all microRNA functional similarity networks are small-worldness and scale-free. The performance of each algorithm was assessed based on average AUC values on 35 disease phenotypes and average rankings of newly discovered disease microRNAs. As a result, the performance on the integrated network was better than that on individual ones. In

  7. Contributions to advances in blend pellet products (BPP) research on molecular structure and molecular nutrition interaction by advanced synchrotron and globar molecular (Micro)spectroscopy.

    Science.gov (United States)

    Guevara-Oquendo, Víctor H; Zhang, Huihua; Yu, Peiqiang

    2018-04-13

    To date, advanced synchrotron-based and globar-sourced techniques are almost unknown to food and feed scientists. There has been little application of these advanced techniques to study blend pellet products at a molecular level. This article aims to provide recent research on advanced synchrotron and globar vibrational molecular spectroscopy contributions to advances in blend pellet products research on molecular structure and molecular nutrition interaction. How processing induced molecular structure changes in relation to nutrient availability and utilization of the blend pellet products. The study reviews Utilization of co-product components for blend pellet product in North America; Utilization and benefits of inclusion of pulse screenings; Utilization of additives in blend pellet products; Application of pellet processing in blend pellet products; Conventional evaluation techniques and methods for blend pellet products. The study focus on recent applications of cutting-edge vibrational molecular spectroscopy for molecular structure and molecular structure association with nutrient utilization in blend pellet products. The information described in this article gives better insight on how advanced molecular (micro)spectroscopy contributions to advances in blend pellet products research on molecular structure and molecular nutrition interaction.

  8. Micro-NRA and micro-3HIXE with 3He microbeam on samples exposed in ASDEX Upgrade and Pilot-PSI machines

    Science.gov (United States)

    Kelemen, Mitja; Založnik, Anže; Vavpetič, Primož; Pečovnik, Matic; Pelicon, Primož; Hakola, Antti; Lahtinen, Aki; Karhunen, Juuso; Piip, Kaarel; Paris, Peeter; Laan, Matti; Krieger, Karl; Oberkofler, Martin; van der Meiden, Hennie; Markelj, Sabina

    2017-08-01

    Micro nuclear reaction analysis (micro-NRA) exploiting the nuclear reaction D(3He,p)4He was used for post-mortem analyses of special marker samples, exposed to deuterium plasma inside ASDEX Upgrade (AUG) tokamak and to the deuterium plasma jet in the Pilot-PSI linear plasma gun. Lateral concentration profiles of deuterium and erosion/deposition profiles of the marker materials were obtained by a combination of micro-NRA and particle induced X-ray emission by 3He beam (3HIXE). In the case of AUG samples, where 25 nm thick W marker layers had been deposited on unpolished and polished graphite substrates, the effect of surface roughness on local erosion and deposition was also investigated. The lateral distribution of W concentration showed that erosion is much more distinct in the case of polished samples and the resulting surface shows a ;leopard; skin pattern of W accumulated on carbon aggregates left on the surface from polishing. The Pilot-PSI samples indicated preferential accumulation of deuterium a few mm off from the centre of the region affected by the plasma beam. This is connected with the largest surface modifications while the thick deposited layers at the centre do not favour deuterium retention per se. The results were cross correlated with those obtained using laser-induced breakdown spectroscopy (LIBS). With its quantitative abilities, micro-NRA provided essential calibration data for in situ LIBS operation, as well as for complementary post mortem Secondary Ion Mass Spectroscopy (SIMS).

  9. Radioactive air sampling methods

    CERN Document Server

    Maiello, Mark L

    2010-01-01

    Although the field of radioactive air sampling has matured and evolved over decades, it has lacked a single resource that assimilates technical and background information on its many facets. Edited by experts and with contributions from top practitioners and researchers, Radioactive Air Sampling Methods provides authoritative guidance on measuring airborne radioactivity from industrial, research, and nuclear power operations, as well as naturally occuring radioactivity in the environment. Designed for industrial hygienists, air quality experts, and heath physicists, the book delves into the applied research advancing and transforming practice with improvements to measurement equipment, human dose modeling of inhaled radioactivity, and radiation safety regulations. To present a wide picture of the field, it covers the international and national standards that guide the quality of air sampling measurements and equipment. It discusses emergency response issues, including radioactive fallout and the assets used ...

  10. Exploring miniature insect brains using micro-CT scanning techniques

    Science.gov (United States)

    Smith, Dylan B.; Bernhardt, Galina; Raine, Nigel E.; Abel, Richard L.; Sykes, Dan; Ahmed, Farah; Pedroso, Inti; Gill, Richard J.

    2016-01-01

    The capacity to explore soft tissue structures in detail is important in understanding animal physiology and how this determines features such as movement, behaviour and the impact of trauma on regular function. Here we use advances in micro-computed tomography (micro-CT) technology to explore the brain of an important insect pollinator and model organism, the bumblebee (Bombus terrestris). Here we present a method for accurate imaging and exploration of insect brains that keeps brain tissue free from trauma and in its natural stereo-geometry, and showcase our 3D reconstructions and analyses of 19 individual brains at high resolution. Development of this protocol allows relatively rapid and cost effective brain reconstructions, making it an accessible methodology to the wider scientific community. The protocol describes the necessary steps for sample preparation, tissue staining, micro-CT scanning and 3D reconstruction, followed by a method for image analysis using the freeware SPIERS. These image analysis methods describe how to virtually extract key composite structures from the insect brain, and we demonstrate the application and precision of this method by calculating structural volumes and investigating the allometric relationships between bumblebee brain structures. PMID:26908205

  11. Advanced Curation Protocols for Mars Returned Sample Handling

    Science.gov (United States)

    Bell, M.; Mickelson, E.; Lindstrom, D.; Allton, J.

    Introduction: Johnson Space Center has over 30 years experience handling precious samples which include Lunar rocks and Antarctic meteorites. However, we recognize that future curation of samples from such missions as Genesis, Stardust, and Mars S mple Return, will require a high degree of biosafety combined witha extremely low levels of inorganic, organic, and biological contamination. To satisfy these requirements, research in the JSC Advanced Curation Lab is currently focused toward two major areas: preliminary examination techniques and cleaning and verification techniques . Preliminary Examination Techniques : In order to minimize the number of paths for contamination we are exploring the synergy between human &robotic sample handling in a controlled environment to help determine the limits of clean curation. Within the Advanced Curation Laboratory is a prototype, next-generation glovebox, which contains a robotic micromanipulator. The remotely operated manipulator has six degrees-of- freedom and can be programmed to perform repetitive sample handling tasks. Protocols are being tested and developed to perform curation tasks such as rock splitting, weighing, imaging, and storing. Techniques for sample transfer enabling more detailed remote examination without compromising the integrity of sample science are also being developed . The glovebox is equipped with a rapid transfer port through which samples can be passed without exposure. The transfer is accomplished by using a unique seal and engagement system which allows passage between containers while maintaining a first seal to the outside environment and a second seal to prevent the outside of the container cover and port door from becoming contaminated by the material being transferred. Cleaning and Verification Techniques: As part of the contamination control effort, innovative cleaning techniques are being identified and evaluated in conjunction with sensitive cleanliness verification methods. Towards this

  12. A fast and sensitive method for evaluating nuclides migration characteristics in rock medium by using micro-channel reactor concept

    Science.gov (United States)

    Okuyama, Keita; Sasahira, Akira; Noshita, Kenji; Yoshida, Takuma; Kato, Kazuyuki; Nagasaki, Shinya; Ohe, Toshiaki

    Experimental effort to evaluate the barrier performance of geologic disposal requires relatively long testing periods and chemically stable conditions. We have developed a new technique, the micro mock-up method, to present a fast and sensitive method to measure both nuclide diffusivity and sorption coefficient within a day to overcome such disadvantage of the conventional method. In this method, a Teflon plate having a micro channel (10-200 μm depth, 2, 4 mm width) is placed just beneath the rock sample plate, radionuclide solution is injected into the channel with constant rate. The breakthrough curve is being measured until a steady state. The outlet flux in the steady state however does not meet the inlet flux because of the matrix diffusion into the rock body. This inlet-outlet difference is simply related to the effective diffusion coefficient ( De) and the distribution coefficient ( Kd) of rock sample. Then, we adopt a fitting procedure to speculate Kd and De values by comparing the observation to the theoretical curve of the two-dimensional diffusion-advection equation. In the present study, we measured De of 3H by using both the micro mock-up method and the conventional through-diffusion method for comparison. The obtained values of De by two different ways for granite sample (Inada area of Japan) were identical: 1.0 × 10 -11 and 9.0 × 10 -12 m 2/s but the testing period was much different: 10 h and 3 days, respectively. We also measured the breakthrough curve of 85Sr and the resulting Kd and De agreed well to the previous study obtained by the batch sorption experiments with crushed samples. The experimental evidence and the above advantages reveal that the micro mock-up method based on the microreactor concept is powerful and much advantageous when compared to the conventional method.

  13. Advanced path sampling of the kinetic network of small proteins

    NARCIS (Netherlands)

    Du, W.

    2014-01-01

    This thesis is focused on developing advanced path sampling simulation methods to study protein folding and unfolding, and to build kinetic equilibrium networks describing these processes. In Chapter 1 the basic knowledge of protein structure and folding theories were introduced and a brief overview

  14. Application of flexible micro temperature sensor in oxidative steam reforming by a methanol micro reformer.

    Science.gov (United States)

    Lee, Chi-Yuan; Lee, Shuo-Jen; Shen, Chia-Chieh; Yeh, Chuin-Tih; Chang, Chi-Chung; Lo, Yi-Man

    2011-01-01

    Advances in fuel cell applications reflect the ability of reformers to produce hydrogen. This work presents a flexible micro temperature sensor that is fabricated based on micro-electro-mechanical systems (MEMS) technology and integrated into a flat micro methanol reformer to observe the conditions inside that reformer. The micro temperature sensor has higher accuracy and sensitivity than a conventionally adopted thermocouple. Despite various micro temperature sensor applications, integrated micro reformers are still relatively new. This work proposes a novel method for integrating micro methanol reformers and micro temperature sensors, subsequently increasing the methanol conversion rate and the hydrogen production rate by varying the fuel supply rate and the water/methanol ratio. Importantly, the proposed micro temperature sensor adequately controls the interior temperature during oxidative steam reforming of methanol (OSRM), with the relevant parameters optimized as well.

  15. Application of Flexible Micro Temperature Sensor in Oxidative Steam Reforming by a Methanol Micro Reformer

    Directory of Open Access Journals (Sweden)

    Yi-Man Lo

    2011-02-01

    Full Text Available Advances in fuel cell applications reflect the ability of reformers to produce hydrogen. This work presents a flexible micro temperature sensor that is fabricated based on micro-electro-mechanical systems (MEMS technology and integrated into a flat micro methanol reformer to observe the conditions inside that reformer. The micro temperature sensor has higher accuracy and sensitivity than a conventionally adopted thermocouple. Despite various micro temperature sensor applications, integrated micro reformers are still relatively new. This work proposes a novel method for integrating micro methanol reformers and micro temperature sensors, subsequently increasing the methanol conversion rate and the hydrogen production rate by varying the fuel supply rate and the water/methanol ratio. Importantly, the proposed micro temperature sensor adequately controls the interior temperature during oxidative steam reforming of methanol (OSRM, with the relevant parameters optimized as well.

  16. Droplet Size-Aware and Error-Correcting Sample Preparation Using Micro-Electrode-Dot-Array Digital Microfluidic Biochips.

    Science.gov (United States)

    Li, Zipeng; Lai, Kelvin Yi-Tse; Chakrabarty, Krishnendu; Ho, Tsung-Yi; Lee, Chen-Yi

    2017-12-01

    Sample preparation in digital microfluidics refers to the generation of droplets with target concentrations for on-chip biochemical applications. In recent years, digital microfluidic biochips (DMFBs) have been adopted as a platform for sample preparation. However, there remain two major problems associated with sample preparation on a conventional DMFB. First, only a (1:1) mixing/splitting model can be used, leading to an increase in the number of fluidic operations required for sample preparation. Second, only a limited number of sensors can be integrated on a conventional DMFB; as a result, the latency for error detection during sample preparation is significant. To overcome these drawbacks, we adopt a next generation DMFB platform, referred to as micro-electrode-dot-array (MEDA), for sample preparation. We propose the first sample-preparation method that exploits the MEDA-specific advantages of fine-grained control of droplet sizes and real-time droplet sensing. Experimental demonstration using a fabricated MEDA biochip and simulation results highlight the effectiveness of the proposed sample-preparation method.

  17. Barbed micro-spikes for micro-scale biopsy

    Science.gov (United States)

    Byun, Sangwon; Lim, Jung-Min; Paik, Seung-Joon; Lee, Ahra; Koo, Kyo-in; Park, Sunkil; Park, Jaehong; Choi, Byoung-Doo; Seo, Jong Mo; Kim, Kyung-ah; Chung, Hum; Song, Si Young; Jeon, Doyoung; Cho, Dongil

    2005-06-01

    Single-crystal silicon planar micro-spikes with protruding barbs are developed for micro-scale biopsy and the feasibility of using the micro-spike as a micro-scale biopsy tool is evaluated for the first time. The fabrication process utilizes a deep silicon etch to define the micro-spike outline, resulting in protruding barbs of various shapes. Shanks of the fabricated micro-spikes are 3 mm long, 100 µm thick and 250 µm wide. Barbs protruding from micro-spike shanks facilitate the biopsy procedure by tearing off and retaining samples from target tissues. Micro-spikes with barbs successfully extracted tissue samples from the small intestines of the anesthetized pig, whereas micro-spikes without barbs failed to obtain a biopsy sample. Parylene coating can be applied to improve the biocompatibility of the micro-spike without deteriorating the biopsy function of the micro-spike. In addition, to show that the biopsy with the micro-spike can be applied to tissue analysis, samples obtained by micro-spikes were examined using immunofluorescent staining. Nuclei and F-actin of cells which are extracted by the micro-spike from a transwell were clearly visualized by immunofluorescent staining.

  18. X-ray fluorescence analysis with micro glass beads using milligram-scale siliceous samples for archeology and geochemistry

    Energy Technology Data Exchange (ETDEWEB)

    Ichikawa, Shintaro, E-mail: sichi@meiji.ac.jp [Organization for the Strategic Coordination of Research and Intellectual Properties, Meiji University, Kawasaki 214-8571 (Japan); Nakamura, Toshihiro [Department of Applied Chemistry, Meiji University, Kawasaki 214-8571 (Japan)

    2014-06-01

    A micro glass bead technique was developed to assay precious siliceous samples for geochemical and archeological analyses. The micro-sized (approximately 3.5 mm in diameter and 0.8 mm in height) glass beads were prepared by mixing and fusing 1.1 mg of the powdered sample and 11.0 mg of the alkali lithium tetraborate flux for wavelength-dispersive X-ray fluorescence determination of major oxides (Na{sub 2}O, MgO, Al{sub 2}O{sub 3}, SiO{sub 2}, P{sub 2}O{sub 5}, K{sub 2}O, CaO, TiO{sub 2}, MnO, and total Fe{sub 2}O{sub 3}). The preparation parameters, including temperature and agitation during the fusing process, were optimized for the use of a commercial platinum crucible rather than a custom-made crucible. The procedure allows preparation of minute sample amounts of siliceous samples using conventional fusing equipment. Synthetic calibration standards were prepared by compounding chemical reagents such as oxides, carbonates, and diphosphates. Calibration curves showed good linearity with r values > 0.997, and the lower limits of detection were in the 10s to 100s of μg g{sup −1} range (e.g., 140 μg g{sup −1} for Na{sub 2}O, 31 μg g{sup −1} for Al{sub 2}O{sub 3}, and 8.9 μg g{sup −1} for MnO). Using the present method, we determined ten major oxides in igneous rocks, stream sediments, ancient potteries, and obsidian. This was applicable to siliceous samples with various compositions, because of the excellent agreement between the analytical and recommended values of six geochemical references. This minimal-scale analysis may be available for precious and limited siliceous samples (e.g., rock, sand, soil, sediment, clay, and archeological ceramics) in many fields such as archeology and geochemistry. - Highlights: • X-ray fluorescence determination of major oxides was performed using 1.1 mg of sample. • Preparation and measurement techniques of the XRF micro glass bead specimen were optimized. • Calibration curves using synthetic standards showed good

  19. A novel method of predicting microRNA-disease associations based on microRNA, disease, gene and environment factor networks.

    Science.gov (United States)

    Peng, Wei; Lan, Wei; Zhong, Jiancheng; Wang, Jianxin; Pan, Yi

    2017-07-15

    MicroRNAs have been reported to have close relationship with diseases due to their deregulation of the expression of target mRNAs. Detecting disease-related microRNAs is helpful for disease therapies. With the development of high throughput experimental techniques, a large number of microRNAs have been sequenced. However, it is still a big challenge to identify which microRNAs are related to diseases. Recently, researchers are interesting in combining multiple-biological information to identify the associations between microRNAs and diseases. In this work, we have proposed a novel method to predict the microRNA-disease associations based on four biological properties. They are microRNA, disease, gene and environment factor. Compared with previous methods, our method makes predictions not only by using the prior knowledge of associations among microRNAs, disease, environment factors and genes, but also by using the internal relationship among these biological properties. We constructed four biological networks based on the similarity of microRNAs, diseases, environment factors and genes, respectively. Then random walking was implemented on the four networks unequally. In the walking course, the associations can be inferred from the neighbors in the same networks. Meanwhile the association information can be transferred from one network to another. The results of experiment showed that our method achieved better prediction performance than other existing state-of-the-art methods. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Low-parachor solvents extraction and thermostated micro-thin-layer chromatography separation for fast screening and classification of spirulina from pharmaceutical formulations and food samples.

    Science.gov (United States)

    Zarzycki, Paweł K; Zarzycka, Magdalena B; Clifton, Vicki L; Adamski, Jerzy; Głód, Bronisław K

    2011-08-19

    The goal of this paper is to demonstrate the separation and detection capability of eco-friendly micro-TLC technique for the classification of spirulina and selected herbs from pharmaceutical and food products. Target compounds were extracted using relatively low-parachor liquids. A number of the spirulina samples which originated from pharmaceutical formulations and food products, were isolated using a simple one step extraction with small volume of methanol, acetone or tetrahydrofuran. Herb samples rich in chlorophyll dyes were analyzed as reference materials. Quantitative data derived from micro-plates under visible light conditions and after iodine staining were explored using chemometrics tools including cluster analysis and principal components analysis. Using this method we could easily distinguish genuine spirulina and non-spirulina samples as well as fresh from expired commercial products and furthermore, we could identify some biodegradation peaks appearing on micro-TLC profiles. This methodology can be applied as a fast screening or fingerprinting tool for the classification of genuine spirulina and herb samples and in particular may be used commercially for the rapid quality control screening of products. Furthermore, this approach allows low-cost fractionation of target substances including cyanobacteria pigments in raw biological or environmental samples for preliminary chemotaxonomic investigations. Due to the low consumption of the mobile phase (usually less than 1 mL per run), this method can be considered as environmentally friendly analytical tool, which may be an alternative for fingerprinting protocols based on HPLC machines and simple separation systems involving planar micro-fluidic or micro-chip devices. Copyright © 2011 Elsevier B.V. All rights reserved.

  1. Adaptive importance sampling for probabilistic validation of advanced driver assistance systems

    NARCIS (Netherlands)

    Gietelink, O.J.; Schutter, B. de; Verhaegen, M.

    2006-01-01

    We present an approach for validation of advanced driver assistance systems, based on randomized algorithms. The new method consists of an iterative randomized simulation using adaptive importance sampling. The randomized algorithm is more efficient than conventional simulation techniques. The

  2. Micro and Nano Techniques for the Handling of Biological Samples

    DEFF Research Database (Denmark)

    Micro and Nano Techniques for the Handling of Biological Samples reviews the different techniques available to manipulate and integrate biological materials in a controlled manner, either by sliding them along a surface (2-D manipulation), or by gripping and moving them to a new position (3-D...

  3. Temperature-controlled micro-TLC: a versatile green chemistry and fast analytical tool for separation and preliminary screening of steroids fraction from biological and environmental samples.

    Science.gov (United States)

    Zarzycki, Paweł K; Slączka, Magdalena M; Zarzycka, Magdalena B; Bartoszuk, Małgorzata A; Włodarczyk, Elżbieta; Baran, Michał J

    2011-11-01

    This paper is a continuation of our previous research focusing on development of micro-TLC methodology under temperature-controlled conditions. The main goal of present paper is to demonstrate separation and detection capability of micro-TLC technique involving simple analytical protocols without multi-steps sample pre-purification. One of the advantages of planar chromatography over its column counterpart is that each TLC run can be performed using non-previously used stationary phase. Therefore, it is possible to fractionate or separate complex samples characterized by heavy biological matrix loading. In present studies components of interest, mainly steroids, were isolated from biological samples like fish bile using single pre-treatment steps involving direct organic liquid extraction and/or deproteinization by freeze-drying method. Low-molecular mass compounds with polarity ranging from estetrol to progesterone derived from the environmental samples (lake water, untreated and treated sewage waters) were concentrated using optimized solid-phase extraction (SPE). Specific bands patterns for samples derived from surface water of the Middle Pomerania in northern part of Poland can be easily observed on obtained micro-TLC chromatograms. This approach can be useful as simple and non-expensive complementary method for fast control and screening of treated sewage water discharged by the municipal wastewater treatment plants. Moreover, our experimental results show the potential of micro-TLC as an efficient tool for retention measurements of a wide range of steroids under reversed-phase (RP) chromatographic conditions. These data can be used for further optimalization of SPE or HPLC systems working under RP conditions. Furthermore, we also demonstrated that micro-TLC based analytical approach can be applied as an effective method for the internal standard (IS) substance search. Generally, described methodology can be applied for fast fractionation or screening of the

  4. In situ sampling of small volumes of soil solution using modified micro-suction cups

    NARCIS (Netherlands)

    Shen, Jianbo; Hoffland, E.

    2007-01-01

    Two modified designs of micro-pore-water samplers were tested for their capacity to collect unbiased soil solution samples containing zinc and citrate. The samplers had either ceramic or polyethersulfone (PES) suction cups. Laboratory tests of the micro-samplers were conducted using (a) standard

  5. Macro- and micro-element analysis in milk samples by inductively coupled plasma-optical emission spectrometry

    Directory of Open Access Journals (Sweden)

    Petrović Sanja M.

    2016-01-01

    Full Text Available The paper describes the determination of Ag, Al, B, Ba, Bi, Ca, Cd, Co, Cr, Cu, Fe, Ga, In, K, Li, Mg, Mn, Na, Ni, Pb, Sr, Tl and Zn, as well as total fat content of milk samples, originated from different sources. The analyzed milk samples were: human milk, fresh cow milk, pasteurized cow milk from a local market, and reconstituted powder milk. The milk samples were obtained from Jablanica District (Serbia territory. Preparation of samples for macro- and micro-analyses was done by wet digestion. Concentrations of the elements after digestion were determined by inductively coupled plasma optical emission spectrometry (ICP-OES. Total fat content of milk samples was determinate by the Weibull and Stoldt method. The results showed that potassium and calcium concentrations were the highest in all samples: 1840.64 - 2993.26 mg/L and 456.05 - 1318.08 mg/L, respectively. Of all heavy metals from the examined milk samples (copper, zinc, manganese, nickel, cadmium, and lead, the most common were zinc and copper, with approximately similar content in the range of 5 - 12 mg/l, while cadmium nickel and manganese were not detected at all. Samples of fresh cow milk and human milk showed the highest fat content of 3.6 and 4.2 %, respectively. Results for total fat and macro- and micro-analyses showed that fresh cow milk has the highest contents of fat and calcium, making it the most nutritious. [Projekat Ministarstva nauke Republike Srbije, br. TR 34012

  6. Evaluation of normalization methods in mammalian microRNA-Seq data

    Science.gov (United States)

    Garmire, Lana Xia; Subramaniam, Shankar

    2012-01-01

    Simple total tag count normalization is inadequate for microRNA sequencing data generated from the next generation sequencing technology. However, so far systematic evaluation of normalization methods on microRNA sequencing data is lacking. We comprehensively evaluate seven commonly used normalization methods including global normalization, Lowess normalization, Trimmed Mean Method (TMM), quantile normalization, scaling normalization, variance stabilization, and invariant method. We assess these methods on two individual experimental data sets with the empirical statistical metrics of mean square error (MSE) and Kolmogorov-Smirnov (K-S) statistic. Additionally, we evaluate the methods with results from quantitative PCR validation. Our results consistently show that Lowess normalization and quantile normalization perform the best, whereas TMM, a method applied to the RNA-Sequencing normalization, performs the worst. The poor performance of TMM normalization is further evidenced by abnormal results from the test of differential expression (DE) of microRNA-Seq data. Comparing with the models used for DE, the choice of normalization method is the primary factor that affects the results of DE. In summary, Lowess normalization and quantile normalization are recommended for normalizing microRNA-Seq data, whereas the TMM method should be used with caution. PMID:22532701

  7. Optical methods for microstructure determination of doped samples

    Science.gov (United States)

    Ciosek, Jerzy F.

    2008-12-01

    The optical methods to determine refractive index profile of layered materials are commonly used with spectroscopic ellipsometry or transmittance/reflectance spectrometry. Measurements of spectral reflection and transmission usually permit to characterize optical materials and determine their refractive index. However, it is possible to characterize of samples with dopants, impurities as well as defects using optical methods. Microstructures of a hydrogenated crystalline Si wafer and a layer of SiO2 - ZrO2 composition are investigated. The first sample is a Si(001):H Czochralski grown single crystalline wafer with 50 nm thick surface Si02 layer. Hydrogen dose implantation (D continue to be an important issue in microelectronic device and sensor fabrication. Hydrogen-implanted silicon (Si: H) has become a topic of remarkable interest, mostly because of the potential of implantation-induced platelets and micro-cavities for the creation of gettering -active areas and for Si layer splitting. Oxygen precipitation and atmospheric impurity are analysed. The second sample is the layer of co-evaporated SiO2 and ZrO2 materials using simultaneously two electron beam guns in reactive evaporation methods. The composition structure was investigated by X-Ray photoelectron spectroscopy (XPS), and spectroscopic ellipsometry methods. A non-uniformity and composition of layer are analysed using average density method.

  8. Laboratory manual on sample preparation procedures for x-ray micro-analysis

    International Nuclear Information System (INIS)

    1997-01-01

    X-ray micro fluorescence is a non-destructive and sensitive method for studying the microscopic distribution of different elements in almost all kinds of samples. Since the beginning of this century, x-rays and electrons have been used for the analysis of many different kinds of material. Techniques which rely on electrons are mainly developed for microscopic studies, and are used in conventional Electron Microscopy (EM) or Scanning Electron Microscopy (SEM), while x-rays are widely used for chemical analysis at the microscopic level. The first chemical analysis by fluorescence spectroscopy using small x-ray beams was conducted in 1928 by Glockner and Schreiber. Since then much work has been devoted to developing different types of optical systems for focusing an x-ray beam, but the efficiency of these systems is still inferior to the conventional electron optical systems. However, even with a poor optical efficiency, the x-ray microbeam has many advantages compared with electron or proton induced x-ray emission methods. These include: The analyses are non-destructive, losses of mass are negligible, and due to the low thermal loading of x-rays, materials which may be thermally degraded can be analysed; Samples can be analysed in air, and no vacuum is required, therefore specimens with volatile components such as water in biological samples, can be imaged at normal pressure and temperature; No charging occurs during analysis and therefore coating of the sample with a conductive layer is not necessary; With these advantages, simpler sample preparation procedures including mounting and preservation can be used

  9. Combined micro-PIXE and NIR Raman spectroscopic plaque characterisation in a human atherosclerotic aorta sample

    International Nuclear Information System (INIS)

    Brands, P.J.M.; Poll, S.W.E. van de; Quaedackers, J.A.; Mutsaers, P.H.A.; Puppels, G.J.; Laarse, A. van der; Voigt, M.J.A. de

    2001-01-01

    Raman spectroscopy can be applied to characterise the chemical composition of an atherosclerotic plaque in vivo. In the near future this technique may become available for use in (coronary) arteries of living patients. For this moment, Raman spectroscopy is applied on artery samples in vitro, to study progression and regression of atherosclerotic plaque. Raman spectroscopy provides chemical information on a molecular basis. In this study, micro-particle induced X-ray emission (micro-PIXE) is applied to provide additional information on the elemental composition of the artery. Furthermore, the combined techniques allow for validation of the structures studied with Raman spectroscopy. This study proves that it is possible to combine and compare both techniques using the same region on the same sample if proper sample preparation is applied. Comparison shows that regions appearing in the Raman spectroscopy results can also be distinguished in micro-PIXE and backscattering spectroscopy (BS) distributions and vice versa. Combining both techniques makes it possible to separate phospholipids from triglycerides. Combined Raman spectroscopy and micro-PIXE/BS is recommended for studying progression and regression of atherosclerosis

  10. Culture methods of allograft musculoskeletal tissue samples in Australian bacteriology laboratories.

    Science.gov (United States)

    Varettas, Kerry

    2013-12-01

    Samples of allograft musculoskeletal tissue are cultured by bacteriology laboratories to determine the presence of bacteria and fungi. In Australia, this testing is performed by 6 TGA-licensed clinical bacteriology laboratories with samples received from 10 tissue banks. Culture methods of swab and tissue samples employ a combination of solid agar and/or broth media to enhance micro-organism growth and maximise recovery. All six Australian laboratories receive Amies transport swabs and, except for one laboratory, a corresponding biopsy sample for testing. Three of the 6 laboratories culture at least one allograft sample directly onto solid agar. Only one laboratory did not use a broth culture for any sample received. An international literature review found that a similar combination of musculoskeletal tissue samples were cultured onto solid agar and/or broth media. Although variations of allograft musculoskeletal tissue samples, culture media and methods are used in Australian and international bacteriology laboratories, validation studies and method evaluations have challenged and supported their use in recovering fungi and aerobic and anaerobic bacteria.

  11. How the RNA isolation method can affect microRNA microarray results

    DEFF Research Database (Denmark)

    Podolska, Agnieszka; Kaczkowski, Bogumil; Litman, Thomas

    2011-01-01

    RNA microarray analysis on porcine brain tissue. One method is a phenol-guanidine isothiocyanate-based procedure that permits isolation of total RNA. The second method, miRVana™ microRNA isolation, is column based and recovers the small RNA fraction alone. We found that microarray analyses give different results...... that depend on the RNA fraction used, in particular because some microRNAs appear very sensitive to the RNA isolation method. We conclude that precautions need to be taken when comparing microarray studies based on RNA isolated with different methods.......The quality of RNA is crucial in gene expression experiments. RNA degradation interferes in the measurement of gene expression, and in this context, microRNA quantification can lead to an incorrect estimation. In the present study, two different RNA isolation methods were used to perform micro...

  12. Progress in micro-pattern gas detectors

    International Nuclear Information System (INIS)

    Bellazzini, Ronaldo

    2001-01-01

    Micro-Pattern Gas Detectors are position-sensitive proportional counters whose sense electrodes are constructed using micro-electronics , thin-film or advanced PCB techniques.The feature size attainable using these methods is of the order of a few microns and the detectors demonstrate excellent spatial resolution and fast charge collection. I will review recent progress on Micro patterned Gas Detectors for tracking and other cross-disciplinary applications.I will focus on the design principles,performance capability and limitations. A short list of interesting applications will be discussed

  13. Stir-bar supported micro-solid-phase extraction for the determination of polychlorinated biphenyl congeners in serum samples.

    Science.gov (United States)

    Sajid, Muhammad; Basheer, Chanbasha

    2016-07-15

    In present work, a new configuration of micro-solid phase extraction was introduced and termed as stir-bar supported micro-solid-phase extraction (SB-μ-SPE). A tiny stir-bar was packed inside the porous polypropylene membrane along with sorbent material and the edges of membrane sheet were heat sealed to secure the contents. The packing of stir-bar inside the μ-SPE device does not allow the device to stick with the wall or any corner of the sample vial during extraction, which is, however, a frequent observation in routine μ-SPE. Moreover, it enhances effective surface area of the sorbent exposed to sample solution through continuous agitation (motion and rotation). It also completely immerses the SB-μ-SPE device in the sample solution even for non-polar sorbents. Polychlorinated biphenyls (PCBs) were selected as model compounds and the method performance was evaluated in human serum samples. After extraction, samples were analyzed by gas chromatography mass spectrometry (GC-MS). The factors that affect extraction efficiency of SB-μ-SPE were optimized. Under optimum conditions, a good linearity (0.1-100ngmL(-1)) with coefficients of determinations ranging from 0.9868 to 0.9992 was obtained. Limits of detections were ranged between 0.003 and 0.047ngmL(-1). Acceptable values for inter-day (3.2-9.1%) and intra-day (3.1-7.2%) relative standard deviations were obtained. The optimized method was successfully applied to determine the concentration of PCB congeners in human serum samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. On-chip micro-power: three-dimensional structures for micro-batteries and micro-supercapacitors

    Science.gov (United States)

    Beidaghi, Majid; Wang, Chunlei

    2010-04-01

    With the miniaturization of portable electronic devices, there is a demand for micro-power source which can be integrated on the semiconductor chips. Various micro-batteries have been developed in recent years to generate or store the energy that is needed by microsystems. Micro-supercapacitors are also developed recently to couple with microbatteries and energy harvesting microsystems and provide the peak power. Increasing the capacity per footprint area of micro-batteries and micro-supercapacitors is a great challenge. One promising route is the manufacturing of three dimensional (3D) structures for these micro-devices. In this paper, the recent advances in fabrication of 3D structure for micro-batteries and micro-supercapacitors are briefly reviewed.

  15. Review on recent and advanced applications of monoliths and related porous polymer gels in micro-fluidic devices

    International Nuclear Information System (INIS)

    Vazquez, Mercedes; Paull, Brett

    2010-01-01

    This review critically summarises recent novel and advanced achievements in the application of monolithic materials and related porous polymer gels in micro-fluidic devices appearing within the literature over the period of the last 5 years (2005-2010). The range of monolithic materials has developed rapidly over the past decade, with a diverse and highly versatile class of materials now available, with each exhibiting distinct porosities, pore sizes, and a wide variety of surface functionalities. A major advantage of these materials is their ease of preparation in micro-fluidic channels by in situ polymerisation, leading to monolithic materials being increasingly utilised for a larger variety of purposes in micro-fluidic platforms. Applications of porous polymer monoliths, silica-based monoliths and related homogeneous porous polymer gels in the preparation of separation columns, ion-permeable membranes, preconcentrators, extractors, electrospray emitters, micro-valves, electrokinetic pumps, micro-reactors and micro-mixers in micro-fluidic devices are discussed herein. Procedures used in the preparation of monolithic materials in micro-channels, as well as some practical aspects of the micro-fluidic chip fabrication are addressed. Recent analytical/bioanalytical and catalytic applications of the final micro-fluidic devices incorporating monolithic materials are also reviewed.

  16. Recent advances in sample preparation techniques and methods of sulfonamides detection - A review.

    Science.gov (United States)

    Dmitrienko, Stanislava G; Kochuk, Elena V; Apyari, Vladimir V; Tolmacheva, Veronika V; Zolotov, Yury A

    2014-11-19

    Sulfonamides (SAs) have been the most widely used antimicrobial drugs for more than 70 years, and their residues in foodstuffs and environmental samples pose serious health hazards. For this reason, sensitive and specific methods for the quantification of these compounds in numerous matrices have been developed. This review intends to provide an updated overview of the recent trends over the past five years in sample preparation techniques and methods for detecting SAs. Examples of the sample preparation techniques, including liquid-liquid and solid-phase extraction, dispersive liquid-liquid microextraction and QuEChERS, are given. Different methods of detecting the SAs present in food and feed and in environmental, pharmaceutical and biological samples are discussed. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Using Micro-Synchrophasor Data for Advanced Distribution Grid Planning and Operations Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Stewart, Emma [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Kiliccote, Sila [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); McParland, Charles [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Roberts, Ciaran [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2014-07-01

    This report reviews the potential for distribution-grid phase-angle data that will be available from new micro-synchrophasors (µPMUs) to be utilized in existing distribution-grid planning and operations analysis. This data could augment the current diagnostic capabilities of grid analysis software, used in both planning and operations for applications such as fault location, and provide data for more accurate modeling of the distribution system. µPMUs are new distribution-grid sensors that will advance measurement and diagnostic capabilities and provide improved visibility of the distribution grid, enabling analysis of the grid’s increasingly complex loads that include features such as large volumes of distributed generation. Large volumes of DG leads to concerns on continued reliable operation of the grid, due to changing power flow characteristics and active generation, with its own protection and control capabilities. Using µPMU data on change in voltage phase angle between two points in conjunction with new and existing distribution-grid planning and operational tools is expected to enable model validation, state estimation, fault location, and renewable resource/load characterization. Our findings include: data measurement is outstripping the processing capabilities of planning and operational tools; not every tool can visualize a voltage phase-angle measurement to the degree of accuracy measured by advanced sensors, and the degree of accuracy in measurement required for the distribution grid is not defined; solving methods cannot handle the high volumes of data generated by modern sensors, so new models and solving methods (such as graph trace analysis) are needed; standardization of sensor-data communications platforms in planning and applications tools would allow integration of different vendors’ sensors and advanced measurement devices. In addition, data from advanced sources such as µPMUs could be used to validate models to improve

  18. Methods and systems for micro machines

    Energy Technology Data Exchange (ETDEWEB)

    Stalford, Harold L.

    2018-03-06

    A micro machine may be in or less than the micrometer domain. The micro machine may include a micro actuator and a micro shaft coupled to the micro actuator. The micro shaft is operable to be driven by the micro actuator. A tool is coupled to the micro shaft and is operable to perform work in response to at least motion of the micro shaft.

  19. MicroCT Scan in paleobiology: application to the study of dental tissues

    Energy Technology Data Exchange (ETDEWEB)

    Rossi, M.; Casali, F. E-mail: casali@bo.infn.it; Romani, D.; Bondioli, L.; Macchiarelli, R.; Rook, L

    2004-01-01

    State of the art in paleoanthropological and paleoprimatological research foresees the use of advanced non-destructive investigative approaches. Microcomputed tomography (microCT) is a fundamental tool, since it offers the opportunity to get high quality morphological information with high spatial resolution. We carried out the set-up of an experimental microCT system able to examine paleobiological samples. The equipment can operate on small objects (size up to 3 cm) with a nominal spatial resolution of 30 {mu}m, allowing their 3D volume reconstruction and morphometric analysis. This approach represents a forefront technique in paleobiological studies, successfully employed only in a limited number of advanced research centers. A specific program of microCT analysis has been planned on a sample of human and non-human fossil primate dentitions, in order to assess the specific nature of a number of tooth lesions (e.g. caries versus abrasion). This currently in progress experimental activity represents the first step for the set-up of a research center specifically devoted to the realization of advanced studies in the field of archaeo-paleobiology.

  20. Sensitivity study of micro four-point probe measurements on small samples

    DEFF Research Database (Denmark)

    Wang, Fei; Petersen, Dirch Hjorth; Hansen, Torben Mikael

    2010-01-01

    probes than near the outer ones. The sensitive area is defined for infinite film, circular, square, and rectangular test pads, and convergent sensitivities are observed for small samples. The simulations show that the Hall sheet resistance RH in micro Hall measurements with position error suppression...

  1. Micro-PIXE evaluation of radioactive cesium transfer in contaminated soil samples

    Science.gov (United States)

    Fujishiro, F.; Ishii, K.; Matsuyama, S.; Arai, H.; Ishizaki, A.; Osada, N.; Sugai, H.; Kusano, K.; Nozawa, Y.; Yamauchi, S.; Karahashi, M.; Oshikawa, S.; Kikuchi, K.; Koshio, S.; Watanabe, K.; Suzuki, Y.

    2014-01-01

    Micro-PIXE analysis has been performed on two soil samples with high cesium activity concentrations. These soil samples were contaminated by fallout from the accident at Fukushima Daiichi Nuclear Power Plant. One exhibits a radioactive cesium transfer of ˜0.01, and the other shows a radioactive cesium transfer of less than 0.001, even though both samples have high cesium activity concentrations exceeding 10,000 Bq/kg. X-ray spectra and elemental images of the soil samples revealed the presence of chlorine, which can react with cesium to produce an inorganic soluble compound, and phosphorus-containing cesium-capturable organic compounds.

  2. Refinement of NMR structures using implicit solvent and advanced sampling techniques.

    Science.gov (United States)

    Chen, Jianhan; Im, Wonpil; Brooks, Charles L

    2004-12-15

    NMR biomolecular structure calculations exploit simulated annealing methods for conformational sampling and require a relatively high level of redundancy in the experimental restraints to determine quality three-dimensional structures. Recent advances in generalized Born (GB) implicit solvent models should make it possible to combine information from both experimental measurements and accurate empirical force fields to improve the quality of NMR-derived structures. In this paper, we study the influence of implicit solvent on the refinement of protein NMR structures and identify an optimal protocol of utilizing these improved force fields. To do so, we carry out structure refinement experiments for model proteins with published NMR structures using full NMR restraints and subsets of them. We also investigate the application of advanced sampling techniques to NMR structure refinement. Similar to the observations of Xia et al. (J.Biomol. NMR 2002, 22, 317-331), we find that the impact of implicit solvent is rather small when there is a sufficient number of experimental restraints (such as in the final stage of NMR structure determination), whether implicit solvent is used throughout the calculation or only in the final refinement step. The application of advanced sampling techniques also seems to have minimal impact in this case. However, when the experimental data are limited, we demonstrate that refinement with implicit solvent can substantially improve the quality of the structures. In particular, when combined with an advanced sampling technique, the replica exchange (REX) method, near-native structures can be rapidly moved toward the native basin. The REX method provides both enhanced sampling and automatic selection of the most native-like (lowest energy) structures. An optimal protocol based on our studies first generates an ensemble of initial structures that maximally satisfy the available experimental data with conventional NMR software using a simplified

  3. Wavelet data processing of micro-Raman spectra of biological samples

    Science.gov (United States)

    Camerlingo, C.; Zenone, F.; Gaeta, G. M.; Riccio, R.; Lepore, M.

    2006-02-01

    A wavelet multi-component decomposition algorithm is proposed for processing data from micro-Raman spectroscopy (μ-RS) of biological tissue. The μ-RS has been recently recognized as a promising tool for the biopsy test and in vivo diagnosis of degenerative human tissue pathologies, due to the high chemical and structural information contents of this spectroscopic technique. However, measurements of biological tissues are usually hampered by typically low-level signals and by the presence of noise and background components caused by light diffusion or fluorescence processes. In order to overcome these problems, a numerical method based on discrete wavelet transform is used for the analysis of data from μ-RS measurements performed in vitro on animal (pig and chicken) tissue samples and, in a preliminary form, on human skin and oral tissue biopsy from normal subjects. Visible light μ-RS was performed using a He-Ne laser and a monochromator with a liquid nitrogen cooled charge coupled device equipped with a grating of 1800 grooves mm-1. The validity of the proposed data procedure has been tested on the well-characterized Raman spectra of reference acetylsalicylic acid samples.

  4. Novel methods of ozone generation by micro-plasma concept

    Energy Technology Data Exchange (ETDEWEB)

    Fateev, A.; Chiper, A.; Chen, W.; Stamate, E.

    2008-02-15

    The project objective was to study the possibilities for new and cheaper methods of generating ozone by means of different types of micro-plasma generators: DBD (Dielectric Barrier Discharge), MHCD (Micro-Hollow Cathode Discharge) and CPED (Capillary Plasma Electrode Discharge). This project supplements another current project where plasma-based DeNOx is being studied and optimised. The results show potentials for reducing ozone generation costs by means of micro-plasmas but that further development is needed. (ln)

  5. Efficient digitalization method for dental restorations using micro-CT data.

    Science.gov (United States)

    Kim, Changhwan; Baek, Seung Hoon; Lee, Taewon; Go, Jonggun; Kim, Sun Young; Cho, Seungryong

    2017-03-15

    The objective of this study was to demonstrate the feasibility of using micro-CT scan of dental impressions for fabricating dental restorations and to compare the dimensional accuracy of dental models generated from various methods. The key idea of the proposed protocol is that dental impression of patients can be accurately digitized by micro-CT scan and that one can make digital cast model from micro-CT data directly. As air regions of the micro-CT scan data of dental impression are equivalent to the real teeth and surrounding structures, one can segment the air regions and fabricate digital cast model in the STL format out of them. The proposed method was validated by a phantom study using a typodont with prepared teeth. Actual measurement and deviation map analysis were performed after acquiring digital cast models for each restoration methods. Comparisons of the milled restorations were also performed by placing them on the prepared teeth of typodont. The results demonstrated that an efficient fabrication of precise dental restoration is achievable by use of the proposed method.

  6. Efficient digitalization method for dental restorations using micro-CT data

    Science.gov (United States)

    Kim, Changhwan; Baek, Seung Hoon; Lee, Taewon; Go, Jonggun; Kim, Sun Young; Cho, Seungryong

    2017-03-01

    The objective of this study was to demonstrate the feasibility of using micro-CT scan of dental impressions for fabricating dental restorations and to compare the dimensional accuracy of dental models generated from various methods. The key idea of the proposed protocol is that dental impression of patients can be accurately digitized by micro-CT scan and that one can make digital cast model from micro-CT data directly. As air regions of the micro-CT scan data of dental impression are equivalent to the real teeth and surrounding structures, one can segment the air regions and fabricate digital cast model in the STL format out of them. The proposed method was validated by a phantom study using a typodont with prepared teeth. Actual measurement and deviation map analysis were performed after acquiring digital cast models for each restoration methods. Comparisons of the milled restorations were also performed by placing them on the prepared teeth of typodont. The results demonstrated that an efficient fabrication of precise dental restoration is achievable by use of the proposed method.

  7. Micro-finite-element method to assess elastic properties of trabecular bone at micro- and macroscopic level.

    Science.gov (United States)

    Rieger, R; Auregan, J C; Hoc, T

    2018-03-01

    The objective of the present study is to assess the mechanical behavior of trabecular bone based on microCT imaging and micro-finite-element analysis. In this way two methods are detailed: (i) direct determination of macroscopic elastic property of trabecular bone; (ii) inverse approach to assess mechanical properties of trabecular bone tissue. Thirty-five females and seven males (forty-two subjects) mean aged (±SD) 80±11.7 years from hospitals of Assistance publique-Hôpitaux de Paris (AP-HP) diagnosed with osteoporosis following a femoral neck fracture due to a fall from standing were included in this study. Fractured heads were collected during hip replacement surgery. Standardized bone cores were removed from the femoral head's equator by a trephine in a water bath. MicroCT images acquisition and analysis were performed with CTan ® software and bone volume fraction was then determined. Micro-finite-element simulations were per-formed using Abaqus 6.9-2 ® software in order to determine the macroscopic mechanical behaviour of the trabecular bone. After microCT acquisition, a longitudinal compression test was performed and the experimental macroscopic Young's Modulus was extracted. An inverse approach based on the whole trabecular bone's mechanical response and micro-finite-element analysis was performed to determine microscopic mechanical properties of trabecular bone. In the present study, elasticity of the tissue was shown to be similar to that of healthy tissue but with a lower yield stress. Classical histomorphometric analysis form microCT imaging associated with an inverse micro-finite-element method allowed to assess microscopic mechanical trabecular bone parameters. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  8. Sample Preparation and Extraction in Small Sample Volumes Suitable for Pediatric Clinical Studies: Challenges, Advances, and Experiences of a Bioanalytical HPLC-MS/MS Method Validation Using Enalapril and Enalaprilat

    Science.gov (United States)

    Burckhardt, Bjoern B.; Laeer, Stephanie

    2015-01-01

    In USA and Europe, medicines agencies force the development of child-appropriate medications and intend to increase the availability of information on the pediatric use. This asks for bioanalytical methods which are able to deal with small sample volumes as the trial-related blood lost is very restricted in children. Broadly used HPLC-MS/MS, being able to cope with small volumes, is susceptible to matrix effects. The latter restrains the precise drug quantification through, for example, causing signal suppression. Sophisticated sample preparation and purification utilizing solid-phase extraction was applied to reduce and control matrix effects. A scale-up from vacuum manifold to positive pressure manifold was conducted to meet the demands of high-throughput within a clinical setting. Faced challenges, advances, and experiences in solid-phase extraction are exemplarily presented on the basis of the bioanalytical method development and validation of low-volume samples (50 μL serum). Enalapril, enalaprilat, and benazepril served as sample drugs. The applied sample preparation and extraction successfully reduced the absolute and relative matrix effect to comply with international guidelines. Recoveries ranged from 77 to 104% for enalapril and from 93 to 118% for enalaprilat. The bioanalytical method comprising sample extraction by solid-phase extraction was fully validated according to FDA and EMA bioanalytical guidelines and was used in a Phase I study in 24 volunteers. PMID:25873972

  9. Sample Preparation and Extraction in Small Sample Volumes Suitable for Pediatric Clinical Studies: Challenges, Advances, and Experiences of a Bioanalytical HPLC-MS/MS Method Validation Using Enalapril and Enalaprilat

    Directory of Open Access Journals (Sweden)

    Bjoern B. Burckhardt

    2015-01-01

    Full Text Available In USA and Europe, medicines agencies force the development of child-appropriate medications and intend to increase the availability of information on the pediatric use. This asks for bioanalytical methods which are able to deal with small sample volumes as the trial-related blood lost is very restricted in children. Broadly used HPLC-MS/MS, being able to cope with small volumes, is susceptible to matrix effects. The latter restrains the precise drug quantification through, for example, causing signal suppression. Sophisticated sample preparation and purification utilizing solid-phase extraction was applied to reduce and control matrix effects. A scale-up from vacuum manifold to positive pressure manifold was conducted to meet the demands of high-throughput within a clinical setting. Faced challenges, advances, and experiences in solid-phase extraction are exemplarily presented on the basis of the bioanalytical method development and validation of low-volume samples (50 μL serum. Enalapril, enalaprilat, and benazepril served as sample drugs. The applied sample preparation and extraction successfully reduced the absolute and relative matrix effect to comply with international guidelines. Recoveries ranged from 77 to 104% for enalapril and from 93 to 118% for enalaprilat. The bioanalytical method comprising sample extraction by solid-phase extraction was fully validated according to FDA and EMA bioanalytical guidelines and was used in a Phase I study in 24 volunteers.

  10. Expression of microRNA related to bone remodeling regulation in plasma in patients with acromegaly

    Directory of Open Access Journals (Sweden)

    Tatiana A. Grebennikova

    2017-11-01

    Full Text Available Backgraund. MiсroRNA are small regulatory factors that regulate gene expression by post-transcriptional regulation of mRNA, playing an important role in numerous cellular processes including organogenesis, apoptosis, cell proliferation and differentiation. Acromegaly causes bone fragility, but the pathogenetic mechanism is generally unknown. Aim. To evaluate levels of microRNA related to bone remodeling regulation in plasma samples from patients with acromegaly Materials and methods. Fasting plasma samples were taken and stored in aliquot at ≤ -80°C from consecutive subjects with clinically evident and biochemically confirmed active acromegaly and healthy volunteers matched by age, sex and body mass index (BMI. miRNeasy Serum/Plasma Kit, TaqMan Advanced miRNA cDNA Synthesis Kit, TaqMan Advanced miRNA Assays were used to assay plasma miRNA expression. Insulin-like growth factor 1 (IGF1 was measured by immunochemiluminescence assay (Liaison. Results. We enrolled 40 subjects 22 patients suffered from acromegaly and 18 matched healthy controls matched by sex, age and BMI. The median age of patients with acromegaly was 42 years (Q25;Q75 – 37;43 with no difference among the groups, p=0.205; BMI – 28 (24;32 kg/m2, p=0.253. The median IGF1 in subjects with acromegaly – 622 (514;1000 ng/ml was significantly higher as compared to the control group (p<0.001. Patients with acromegaly had significantly higher expression of microRNA-100-5р (p=0.051, microRNA-550а-5р (p=0.048, microRNA-7b-5р (p=0.005 and microRNA-96-5р (p=0.042 among 27 bone-specific microRNA tested in plasma Conclusions. This study reveals that several microRNAs, known to regulate bone remodeling can be detected in plasma samples of patients with acromegaly and may be suggested as biomarkers for skeletal involvement in patients with acromegaly.

  11. Multiplicity and contiguity of ablation mechanisms in laser-assisted analytical micro-sampling

    International Nuclear Information System (INIS)

    Bleiner, Davide; Bogaerts, Annemie

    2006-01-01

    Laser ablation is implemented in several scientific and technological fields, as well as a rapid sample introduction technique in elemental and trace analysis. At high laser fluence, the ejection of micro-sized droplets causes the enhancement of the surface recession speed and depth resolution degradation as well as the alteration of the sampling stoichiometry. The origin of such large particles seems to be due to at least two different processes, phase explosion and melt splashing. Experimental evidence for both was found in metallic matrices, whereas non-metallic samples showed more complex phenomena like cracking. The spatial distribution of the beam energy profile is responsible for significant differences in the ablation mechanism across the irradiated region and for heterogeneous sampling. Under Gaussian irradiance distribution, the center of the crater, where the irradiance is the highest, experienced a fast heating with rapid ejection of a mixture of particles and vapor (spinodal breakdown). The crater periphery was subjected to more modest irradiation, with melt mobilization and walls formation. The overall resulting particle size distribution was composed of an abundant nano-sized fraction, produced by vapor condensation, and a micro-sized fraction during melt expulsion

  12. A modified captive bubble method for determining advancing and receding contact angles

    International Nuclear Information System (INIS)

    Xue, Jian; Shi, Pan; Zhu, Lin; Ding, Jianfu; Chen, Qingmin; Wang, Qingjun

    2014-01-01

    Graphical abstract: - Highlights: • A modified captive bubble method for determining advancing and receding contact angle is proposed. • We have designed a pressure chamber with a pressure control system to the original experimental. • The modified method overcomes the deviation of the bubble in the traditional captive bubble method. • The modified captive bubble method allows a smaller error from the test. - Abstract: In this work, a modification to the captive bubble method was proposed to test the advancing and receding contact angle. This modification is done by adding a pressure chamber with a pressure control system to the original experimental system equipped with an optical angle mater equipped with a high speed CCD camera, a temperature control system and a computer. A series of samples with highly hydrophilic, hydrophilic, hydrophobic and superhydrophobic surfaces were prepared. The advancing and receding contact angles of these samples with highly hydrophilic, hydrophilic, and hydrophobic surfaces through the new methods was comparable to the result tested by the traditional sessile drop method. It is proved that this method overcomes the limitation of the traditional captive bubble method and the modified captive bubble method allows a smaller error from the test. However, due to the nature of the captive bubble technique, this method is also only suitable for testing the surface with advancing or receding contact angle below 130°

  13. A modified captive bubble method for determining advancing and receding contact angles

    Energy Technology Data Exchange (ETDEWEB)

    Xue, Jian; Shi, Pan; Zhu, Lin [Key Laboratory of High Performance Polymer Materials and Technology (Nanjing University), Ministry of Eduction, Nanjing 210093 (China); Ding, Jianfu [Security and Disruptive Technologies, National Research Council Canada, 1200 Montreal Road, Ottawa, K1A 0R6, Ontario (Canada); Chen, Qingmin [Key Laboratory of High Performance Polymer Materials and Technology (Nanjing University), Ministry of Eduction, Nanjing 210093 (China); Wang, Qingjun, E-mail: njuwqj@nju.edu.cn [Key Laboratory of High Performance Polymer Materials and Technology (Nanjing University), Ministry of Eduction, Nanjing 210093 (China)

    2014-03-01

    Graphical abstract: - Highlights: • A modified captive bubble method for determining advancing and receding contact angle is proposed. • We have designed a pressure chamber with a pressure control system to the original experimental. • The modified method overcomes the deviation of the bubble in the traditional captive bubble method. • The modified captive bubble method allows a smaller error from the test. - Abstract: In this work, a modification to the captive bubble method was proposed to test the advancing and receding contact angle. This modification is done by adding a pressure chamber with a pressure control system to the original experimental system equipped with an optical angle mater equipped with a high speed CCD camera, a temperature control system and a computer. A series of samples with highly hydrophilic, hydrophilic, hydrophobic and superhydrophobic surfaces were prepared. The advancing and receding contact angles of these samples with highly hydrophilic, hydrophilic, and hydrophobic surfaces through the new methods was comparable to the result tested by the traditional sessile drop method. It is proved that this method overcomes the limitation of the traditional captive bubble method and the modified captive bubble method allows a smaller error from the test. However, due to the nature of the captive bubble technique, this method is also only suitable for testing the surface with advancing or receding contact angle below 130°.

  14. Launch Vehicles Based on Advanced Hybrid Rocket Motors: An Enabling Technology for the Commercial Small and Micro Satellite Planetary Science

    Science.gov (United States)

    Karabeyoglu, Arif; Tuncer, Onur; Inalhan, Gokhan

    2016-07-01

    Mankind is relient on chemical propulsion systems for space access. Nevertheless, this has been a stagnant area in terms of technological development and the technology base has not changed much almost for the past forty years. This poses a vicious circle for launch applications such that high launch costs constrain the demand and low launch freqencies drive costs higher. This also has been a key limiting factor for small and micro satellites that are geared towards planetary science. Rather this be because of the launch frequencies or the costs, the access of small and micro satellites to orbit has been limited. With today's technology it is not possible to escape this circle. However the emergence of cost effective and high performance propulsion systems such as advanced hybrid rockets can decrease launch costs by almost an order or magnitude. This paper briefly introduces the timeline and research challenges that were overcome during the development of advanced hybrid LOX/paraffin based rockets. Experimental studies demonstrated effectiveness of these advanced hybrid rockets which incorporate fast burning parafin based fuels, advanced yet simple internal balistic design and carbon composite winding/fuel casting technology that enables the rocket motor to be built from inside out. A feasibility scenario is studied using these rocket motors as building blocks for a modular launch vehicle capable of delivering micro satellites into low earth orbit. In addition, the building block rocket motor can be used further solar system missions providing the ability to do standalone small and micro satellite missions to planets within the solar system. This enabling technology therefore offers a viable alternative in order to escape the viscous that has plagued the space launch industry and that has limited the small and micro satellite delivery for planetary science.

  15. Scout-view assisted interior micro-CT

    International Nuclear Information System (INIS)

    Sharma, Kriti Sen; Narayanan, Shree; Agah, Masoud; Holzner, Christian; Vasilescu, Dragoş M; Jin, Xin; Hoffman, Eric A; Yu, Hengyong; Wang, Ge

    2013-01-01

    Micro computed tomography (micro-CT) is a widely-used imaging technique. A challenge of micro-CT is to quantitatively reconstruct a sample larger than the field-of-view (FOV) of the detector. This scenario is characterized by truncated projections and associated image artifacts. However, for such truncated scans, a low resolution scout scan with an increased FOV is frequently acquired so as to position the sample properly. This study shows that the otherwise discarded scout scans can provide sufficient additional information to uniquely and stably reconstruct the interior region of interest. Two interior reconstruction methods are designed to utilize the multi-resolution data without significant computational overhead. While most previous studies used numerically truncated global projections as interior data, this study uses truly hybrid scans where global and interior scans were carried out at different resolutions. Additionally, owing to the lack of standard interior micro-CT phantoms, we designed and fabricated novel interior micro-CT phantoms for this study to provide means of validation for our algorithms. Finally, two characteristic samples from separate studies were scanned to show the effect of our reconstructions. The presented methods show significant improvements over existing reconstruction algorithms. (paper)

  16. Measurement of micro Bubbles generated by a pressurized dissolution method

    Energy Technology Data Exchange (ETDEWEB)

    Hosokawa, S; Tanaka, K; Tomiyama, A [Kobe University, 1-1 Rokkodai, Nada, Kobe 657-8501 (Japan); Maeda, Y; Yamaguchi, S; Ito, Y, E-mail: hosokawa@mech.kobe-u.ac.j [Panasonic Electric Works Co., Ltd., 1048 Kadoma, Osaka 571-8686 (Japan)

    2009-02-01

    Diameters of micro-bubbles are apt to range from about one mm to several-hundred mm, and therefore, it is difficult to measure a correct diameter distribution using a single measurement method. In this study, diameters of bubbles generated by a pressurized dissolution method are measured by using phase Doppler anemometry (PDA) and an image processing method, which is based on the Sobel filter and Hough transform. The diameter distribution and the Sauter mean diameter of micro bubbles are evaluated based on the diameters measured by both methods. Experiments are conducted for several mass flow rates of dissolved gas and of air bubbles entrained in the upstream of the decompression nozzle to examine effects of the entrained bubbles on bubble diameter. As a result, the following conclusions are obtained: (1) Diameter distribution of micro bubbles can be accurately measured for a wide range of diameter by using PDA and the image processing method. (2) The mean diameter of micro-bubbles generated by gasification of dissolved gas is smaller than that generated by breakup of air bubbles entrained in the upstream of the decompression nozzle. (3) The mean bubble diameter increases with the entrainment of air bubbles in the upstream of the decompression nozzle at a constant mass flow rate of dissolved gas.

  17. Measurement of micro Bubbles generated by a pressurized dissolution method

    International Nuclear Information System (INIS)

    Hosokawa, S; Tanaka, K; Tomiyama, A; Maeda, Y; Yamaguchi, S; Ito, Y

    2009-01-01

    Diameters of micro-bubbles are apt to range from about one mm to several-hundred mm, and therefore, it is difficult to measure a correct diameter distribution using a single measurement method. In this study, diameters of bubbles generated by a pressurized dissolution method are measured by using phase Doppler anemometry (PDA) and an image processing method, which is based on the Sobel filter and Hough transform. The diameter distribution and the Sauter mean diameter of micro bubbles are evaluated based on the diameters measured by both methods. Experiments are conducted for several mass flow rates of dissolved gas and of air bubbles entrained in the upstream of the decompression nozzle to examine effects of the entrained bubbles on bubble diameter. As a result, the following conclusions are obtained: (1) Diameter distribution of micro bubbles can be accurately measured for a wide range of diameter by using PDA and the image processing method. (2) The mean diameter of micro-bubbles generated by gasification of dissolved gas is smaller than that generated by breakup of air bubbles entrained in the upstream of the decompression nozzle. (3) The mean bubble diameter increases with the entrainment of air bubbles in the upstream of the decompression nozzle at a constant mass flow rate of dissolved gas.

  18. Micro and Nano-Scale Technologies for Cell Mechanics

    Directory of Open Access Journals (Sweden)

    Mustafa Unal

    2014-10-01

    Full Text Available Cell mechanics is a multidisciplinary field that bridges cell biology, fundamental mechanics, and micro and nanotechnology, which synergize to help us better understand the intricacies and the complex nature of cells in their native environment. With recent advances in nanotechnology, microfabrication methods and micro-electro-mechanical-systems (MEMS, we are now well situated to tap into the complex micro world of cells. The field that brings biology and MEMS together is known as Biological MEMS (BioMEMS. BioMEMS take advantage of systematic design and fabrication methods to create platforms that allow us to study cells like never before. These new technologies have been rapidly advancing the study of cell mechanics. This review article provides a succinct overview of cell mechanics and comprehensively surveys micro and nano-scale technologies that have been specifically developed for and are relevant to the mechanics of cells. Here we focus on micro and nano-scale technologies, and their applications in biology and medicine, including imaging, single cell analysis, cancer cell mechanics, organ-on-a-chip systems, pathogen detection, implantable devices, neuroscience and neurophysiology. We also provide a perspective on the future directions and challenges of technologies that relate to the mechanics of cells.

  19. Preparation and evaluation of molecularly imprinted solid-phase micro-extraction fibers for selective extraction of phthalates in an aqueous sample

    International Nuclear Information System (INIS)

    He Juan; Lv Ruihe; Zhan Haijun; Wang Huizhi; Cheng Jie; Lu Kui; Wang Fengcheng

    2010-01-01

    A novel molecularly imprinted polymer (MIP) that was applied to a solid-phase micro-extraction (SPME) device, which could be coupled directly to gas chromatograph and mass spectrometer (GC/MS), was prepared using dibutyl phthalate (DBP) as the template molecule. The characteristics and application of this fiber were investigated. Electron microscope images indicated that the MIP-coated solid-phase micro-extraction (MI-SPME) fibers were homogeneous and porous. The extraction yield of DBP with the MI-SPME fibers was higher than that of the non-imprinted polymer (NIP)-coated SPME (NI-SPME) fibers. The MI-SPME fibers had a higher selectivity to other phthalates that had similar structures as DBP. A method was developed for the determination of phthalates using MI-SPME fibers coupled with GC/MS. The extraction conditions were optimized. Detection limits for the phthalate samples were within the range of 2.17-20.84 ng L -1 . The method was applied to five kinds of phthalates dissolved in spiked aqueous samples and resulted in recoveries of up to 94.54-105.34%, respectively. Thus, the MI-SPME fibers are suitable for the extraction of trace phthalates in complicated samples.

  20. Study of on-machine error identification and compensation methods for micro machine tools

    International Nuclear Information System (INIS)

    Wang, Shih-Ming; Yu, Han-Jen; Lee, Chun-Yi; Chiu, Hung-Sheng

    2016-01-01

    Micro machining plays an important role in the manufacturing of miniature products which are made of various materials with complex 3D shapes and tight machining tolerance. To further improve the accuracy of a micro machining process without increasing the manufacturing cost of a micro machine tool, an effective machining error measurement method and a software-based compensation method are essential. To avoid introducing additional errors caused by the re-installment of the workpiece, the measurement and compensation method should be on-machine conducted. In addition, because the contour of a miniature workpiece machined with a micro machining process is very tiny, the measurement method should be non-contact. By integrating the image re-constructive method, camera pixel correction, coordinate transformation, the error identification algorithm, and trajectory auto-correction method, a vision-based error measurement and compensation method that can on-machine inspect the micro machining errors and automatically generate an error-corrected numerical control (NC) program for error compensation was developed in this study. With the use of the Canny edge detection algorithm and camera pixel calibration, the edges of the contour of a machined workpiece were identified and used to re-construct the actual contour of the work piece. The actual contour was then mapped to the theoretical contour to identify the actual cutting points and compute the machining errors. With the use of a moving matching window and calculation of the similarity between the actual and theoretical contour, the errors between the actual cutting points and theoretical cutting points were calculated and used to correct the NC program. With the use of the error-corrected NC program, the accuracy of a micro machining process can be effectively improved. To prove the feasibility and effectiveness of the proposed methods, micro-milling experiments on a micro machine tool were conducted, and the results

  1. Simulations of Micro Gas Flows by the DS-BGK Method

    KAUST Repository

    Li, Jun

    2011-01-01

    For gas flows in micro devices, the molecular mean free path is of the same order as the characteristic scale making the Navier-Stokes equation invalid. Recently, some micro gas flows are simulated by the DS-BGK method, which is convergent

  2. Online Optimization Method for Operation of Generators in a Micro Grid

    Science.gov (United States)

    Hayashi, Yasuhiro; Miyamoto, Hideki; Matsuki, Junya; Iizuka, Toshio; Azuma, Hitoshi

    Recently a lot of studies and developments about distributed generator such as photovoltaic generation system, wind turbine generation system and fuel cell have been performed under the background of the global environment issues and deregulation of the electricity market, and the technique of these distributed generators have progressed. Especially, micro grid which consists of several distributed generators, loads and storage battery is expected as one of the new operation system of distributed generator. However, since precipitous load fluctuation occurs in micro grid for the reason of its smaller capacity compared with conventional power system, high-accuracy load forecasting and control scheme to balance of supply and demand are needed. Namely, it is necessary to improve the precision of operation in micro grid by observing load fluctuation and correcting start-stop schedule and output of generators online. But it is not easy to determine the operation schedule of each generator in short time, because the problem to determine start-up, shut-down and output of each generator in micro grid is a mixed integer programming problem. In this paper, the authors propose an online optimization method for the optimal operation schedule of generators in micro grid. The proposed method is based on enumeration method and particle swarm optimization (PSO). In the proposed method, after picking up all unit commitment patterns of each generators satisfied with minimum up time and minimum down time constraint by using enumeration method, optimal schedule and output of generators are determined under the other operational constraints by using PSO. Numerical simulation is carried out for a micro grid model with five generators and photovoltaic generation system in order to examine the validity of the proposed method.

  3. Size distributions of micro-bubbles generated by a pressurized dissolution method

    Science.gov (United States)

    Taya, C.; Maeda, Y.; Hosokawa, S.; Tomiyama, A.; Ito, Y.

    2012-03-01

    Size of micro-bubbles is widely distributed in the range of one to several hundreds micrometers and depends on generation methods, flow conditions and elapsed times after the bubble generation. Although a size distribution of micro-bubbles should be taken into account to improve accuracy in numerical simulations of flows with micro-bubbles, a variety of the size distribution makes it difficult to introduce the size distribution in the simulations. On the other hand, several models such as the Rosin-Rammler equation and the Nukiyama-Tanazawa equation have been proposed to represent the size distribution of particles or droplets. Applicability of these models to the size distribution of micro-bubbles has not been examined yet. In this study, we therefore measure size distribution of micro-bubbles generated by a pressurized dissolution method by using a phase Doppler anemometry (PDA), and investigate the applicability of the available models to the size distributions of micro-bubbles. Experimental apparatus consists of a pressurized tank in which air is dissolved in liquid under high pressure condition, a decompression nozzle in which micro-bubbles are generated due to pressure reduction, a rectangular duct and an upper tank. Experiments are conducted for several liquid volumetric fluxes in the decompression nozzle. Measurements are carried out at the downstream region of the decompression nozzle and in the upper tank. The experimental results indicate that (1) the Nukiyama-Tanasawa equation well represents the size distribution of micro-bubbles generated by the pressurized dissolution method, whereas the Rosin-Rammler equation fails in the representation, (2) the bubble size distribution of micro-bubbles can be evaluated by using the Nukiyama-Tanasawa equation without individual bubble diameters, when mean bubble diameter and skewness of the bubble distribution are given, and (3) an evaluation method of visibility based on the bubble size distribution and bubble

  4. Development of sealed sample containers and high resolution micro-tomography

    Energy Technology Data Exchange (ETDEWEB)

    Uesugi, Kentaro, E-mail: ueken@spring8.or.jp; Takeuchi, Akihisa; Suzuki, Yoshio [Japan synchrotron radiation research institute, JASRI/SPring-8 Kouto 1-1-1, Sayo, Hyogo 679-5198 Japan (Japan); Uesugi, Masayuki [Japan Aerospace Exploration Agency (ISAS/JAXA), Sagamihara, Kanagawa 252-5210 (Japan); Hamada, Hiroshi [NTT Advanced technology Corporation, Atsugi, Kanagawa 243-0124 (Japan)

    2016-01-28

    A sample container and a high resolution micro-tomography system have been developed at BL47XU at SPring-8. The container is made of a SiN membrane in a shape of truncated pyramid, which makes it possible to exclude oxygen and moisture in the air. The sample rotation stage for tomography is set downward to keep the sample in the container without any glue. The spatial resolution and field of view are 300 nm and 110 μm using a Fresnel zone plate objective with an outermost zone width of 100 nm at 8 keV, respectively. The scan time is about 20 minutes for 1800 projections. A 3-D image of an asteroid particle was successfully obtained without adhesive and contamination.

  5. Advances with microRNAs in Parkinson’s disease research

    Directory of Open Access Journals (Sweden)

    Ma L

    2013-10-01

    Full Text Available Liuqing Ma,1,2,* Liangming Wei,3,* Fei Wu,2,* Zhenhua Hu,2 Zhenguo Liu,1 Weien Yuan2 1Department of Neurology, Xinhua Hospital affiliated with Shanghai JiaoTong University School of Medicine, Shanghai, People’s Republic of China; 2School of Pharmacy, Shanghai JiaoTong University, Shanghai, People’s Republic of China; 3Research Institute of Micro/Nano Science and Technology, Shanghai JiaoTong University, Shanghai, People’s Republic of China *These authors contributed equally to this work Abstract: Parkinson’s disease (PD is the second-most common age-dependent neurodegenerative disorder and is caused by severe degeneration of dopaminergic neurons in the substantia nigra pars compacta. Unfortunately, current treatment only targets symptoms and involves dopamine replacement therapy, which does not counteract progressive degeneration. MicroRNAs (miRNAs are a class of small RNA molecules implicated in post-transcriptional regulation of gene expression during development. Recent studies show that miRNAs are playing an important role in the pathophysiology of PD. miRNA-based therapy is a powerful tool with which to study gene function, investigate the mechanism of the disease, and validate drug targets. In this review, we focus on the recent advances of the use of miRNAs in the pathogenesis of PD. Keywords: miRNA, α-synuclein, LRRK2, miRNA-based therapy, pathophysiology

  6. Perilymph sampling from the cochlear apex: a reliable method to obtain higher purity perilymph samples from scala tympani.

    Science.gov (United States)

    Salt, Alec N; Hale, Shane A; Plonkte, Stefan K R

    2006-05-15

    Measurements of drug levels in the fluids of the inner ear are required to establish kinetic parameters and to determine the influence of specific local delivery protocols. For most substances, this requires cochlear fluids samples to be obtained for analysis. When auditory function is of primary interest, the drug level in the perilymph of scala tympani (ST) is most relevant, since drug in this scala has ready access to the auditory sensory cells. In many prior studies, ST perilymph samples have been obtained from the basal turn, either by aspiration through the round window membrane (RWM) or through an opening in the bony wall. A number of studies have demonstrated that such samples are likely to be contaminated with cerebrospinal fluid (CSF). CSF enters the basal turn of ST through the cochlear aqueduct when the bony capsule is perforated or when fluid is aspirated. The degree of sample contamination has, however, not been widely appreciated. Recent studies have shown that perilymph samples taken through the round window membrane are highly contaminated with CSF, with samples greater than 2microL in volume containing more CSF than perilymph. In spite of this knowledge, many groups continue to sample from the base of the cochlea, as it is a well-established method. We have developed an alternative, technically simple method to increase the proportion of ST perilymph in a fluid sample. The sample is taken from the apex of the cochlea, a site that is distant from the cochlear aqueduct. A previous problem with sampling through a perforation in the bone was that the native perilymph rapidly leaked out driven by CSF pressure and was lost to the middle ear space. We therefore developed a procedure to collect all the fluid that emerged from the perforated apex after perforation. We evaluated the method using a marker ion trimethylphenylammonium (TMPA). TMPA was applied to the perilymph of guinea pigs either by RW irrigation or by microinjection into the apical turn. The

  7. Micro-Raman depth profile investigations of beveled Al+-ion implanted 6H-SiC samples

    International Nuclear Information System (INIS)

    Zuk, J.; Romanek, J.; Skorupa, W.

    2009-01-01

    6H-SiC single crystals were implanted with 450 keV Al + -ions to a fluence of 3.4 x 10 15 cm -2 , and in a separate experiment subjected to multiple Al + implantations with the four energies: 450, 240, 115 and 50 keV and different fluences to obtain rectangular-like depth distributions of Al in SiC. The implantations were performed along [0 0 0 1] channeling and non-channeling ('random') directions. Subsequently, the samples were annealed for 10 min at 1650 deg. C in an argon atmosphere. The depth profiles of the implanted Al atoms were obtained by secondary ion mass spectrometry (SIMS). Following implantation and annealing, the samples were beveled by mechanical polishing. Confocal micro-Raman spectroscopic investigations were performed with a 532 nm wavelength laser beam of a 1 μm focus diameter. The technique was used to determine precisely the depth profiles of TO and LO phonon lines intensity in the beveled samples to a depth of about 2000 nm. Micro-Raman spectroscopy was also found to be useful in monitoring very low levels of disorder remaining in the Al + implanted and annealed 6H-SiC samples. The micro-Raman technique combined with sample beveling also made it possible the determination of optical absorption coefficient profiles in implanted subsurface layers.

  8. Simulation of Micro-Channel and Micro-Orifice Flow Using Lattice Boltzmann Method with Langmuir Slip Model

    Directory of Open Access Journals (Sweden)

    A. R. Rahmati

    2016-12-01

    Full Text Available Because of its kinetic nature and computational advantages, the Lattice Boltzmann method (LBM has been well accepted as a useful tool to simulate micro-scale flows. The slip boundary model plays a crucial role in the accuracy of solutions for micro-channel flow simulations. The most used slip boundary condition is the Maxwell slip model. The results of Maxwell slip model are affected by the accommodation coefficient significantly, but there is not an explicitly relationship between properties at wall and accommodation coefficient. In the present wok, Langmuir slip model is used beside LBM to simulate micro-channel and micro-orifice flows. Slip velocity and nonlinear pressure drop profiles are presented as two major effects in such flows. The results are in good agreement with existing results in the literature.

  9. Three-phase solvent bar micro-extraction as an approach to silver ultra-traces speciation in estuarine water samples.

    Science.gov (United States)

    López-López, José Antonio; Herce-Sesa, Belén; Moreno, Carlos

    2015-01-01

    Silver ion inputs into the environment due to human activities have been increased in the last years because it has been used as a bactericide with application in medical, homecare and self-care products. In addition, it is toxic at low concentration for aquatic organisms. In estuarine waters, salinity and dissolved organic matter (DOM) regulate Ag(+) concentration by the formation of complexes as AgCln((n-1)-) and Ag-DOM. Difficulties of Ag(+) analysis in estuaries are associated to its low concentration level and interferences of sample matrix. Liquid and solid phase extraction methods have been used for speciation of silver in waters; however, miniaturized methods that offer a better environmental profile are desirable. Hollow fiber liquid phase micro-extraction (HFLPME) allows obtaining higher pre-concentration factors with a reduction of waste generation. Notwithstanding, some operational improvements are needed to permit their use as a routine method that can be afforded using a configuration of three-phase solvent bar micro-extraction (3PSBME). In this work, tri-isobutylphosphine sulphide (TIBPS) has been used as an extractant for Ag(+) pre-concentration in estuarine waters by 3PSBME. Under optimized conditions, Ag(+) has been pre-concentrated 60 times and the method presents a limit of detection of 1.53 ng L(-1). To evaluate which Ag species is transported by TIBPS, Cl(-) and DOM have been added to synthetic samples. As a result, a decrease in Ag pre-concentration efficiency after additions has been observed and quantified. Results showed that Ag(+) is selectively transported by TIBPS from estuarine water samples after comparison of the results with those obtained by the reference method of liquid extraction with APDC/DDDC. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Advances on micro-RWELL gaseous detector

    CERN Document Server

    Morello, Gianfranco; Benussi, L; De Simone, P; Felici, G; Gatta, M; Poli Lener, M; De Oliveira, R; Ochi, A; Borgonovi, L; Giacomelli, P; Ranieri, A; Valentino, V; Ressegotti, M; Vai, I

    2017-01-01

    The R&D; on the micro-Resistive-WELL ($\\mu$-RWELL) detector technology aims in developing a new scalable, compact, spark-protected, single amplification stage Micro-Pattern Gas Detectors (MPGD) for large area HEP applications as tracking and calorimeter device as well as for industrial and medical applications as X-ray and neutron imaging gas pixel detector. The novel micro- structure, exploiting several solutions and improvements achieved in the last years for MPGDs, in particular for GEMs and Micromegas, is an extremely simple detector allowing an easy engineering with consequent technological transfer toward the photolithography industry. Large area detectors (up $1 \\times 2 m^2$) can be realized splicing $\\mu$-RWELL_PCB tiles of smaller size (about $0.5 \\times 1 m^2$ - typical PCB industrial size). The detector, composed by few basic elements such as the readout-PCB embedded with the amplification stage (through the resistive layer) and the cathode defining the gas drift-conversion gap has been largel...

  11. Simulations of Micro Gas Flows by the DS-BGK Method

    KAUST Repository

    Li, Jun

    2011-01-01

    For gas flows in micro devices, the molecular mean free path is of the same order as the characteristic scale making the Navier-Stokes equation invalid. Recently, some micro gas flows are simulated by the DS-BGK method, which is convergent to the BGK equation and very efficient for low-velocity cases. As the molecular reflection on the boundary is the dominant effect compared to the intermolecular collisions in micro gas flows, the more realistic boundary condition, namely the CLL reflection model, is employed in the DS-BGK simulation and the influence of the accommodation coefficients used in the molecular reflection model on the results are discussed. The simulation results are verified by comparison with those of the DSMC method as criteria. Copyright © 2011 by ASME.

  12. Micro-Droplet Detection Method for Measuring the Concentration of Alkaline Phosphatase-Labeled Nanoparticles in Fluorescence Microscopy.

    Science.gov (United States)

    Li, Rufeng; Wang, Yibei; Xu, Hong; Fei, Baowei; Qin, Binjie

    2017-11-21

    This paper developed and evaluated a quantitative image analysis method to measure the concentration of the nanoparticles on which alkaline phosphatase (AP) was immobilized. These AP-labeled nanoparticles are widely used as signal markers for tagging biomolecules at nanometer and sub-nanometer scales. The AP-labeled nanoparticle concentration measurement can then be directly used to quantitatively analyze the biomolecular concentration. Micro-droplets are mono-dispersed micro-reactors that can be used to encapsulate and detect AP-labeled nanoparticles. Micro-droplets include both empty micro-droplets and fluorescent micro-droplets, while fluorescent micro-droplets are generated from the fluorescence reaction between the APs adhering to a single nanoparticle and corresponding fluorogenic substrates within droplets. By detecting micro-droplets and calculating the proportion of fluorescent micro-droplets to the overall micro-droplets, we can calculate the AP-labeled nanoparticle concentration. The proposed micro-droplet detection method includes the following steps: (1) Gaussian filtering to remove the noise of overall fluorescent targets, (2) a contrast-limited, adaptive histogram equalization processing to enhance the contrast of weakly luminescent micro-droplets, (3) an red maximizing inter-class variance thresholding method (OTSU) to segment the enhanced image for getting the binary map of the overall micro-droplets, (4) a circular Hough transform (CHT) method to detect overall micro-droplets and (5) an intensity-mean-based thresholding segmentation method to extract the fluorescent micro-droplets. The experimental results of fluorescent micro-droplet images show that the average accuracy of our micro-droplet detection method is 0.9586; the average true positive rate is 0.9502; and the average false positive rate is 0.0073. The detection method can be successfully applied to measure AP-labeled nanoparticle concentration in fluorescence microscopy.

  13. Micro-Droplet Detection Method for Measuring the Concentration of Alkaline Phosphatase-Labeled Nanoparticles in Fluorescence Microscopy

    Directory of Open Access Journals (Sweden)

    Rufeng Li

    2017-11-01

    Full Text Available This paper developed and evaluated a quantitative image analysis method to measure the concentration of the nanoparticles on which alkaline phosphatase (AP was immobilized. These AP-labeled nanoparticles are widely used as signal markers for tagging biomolecules at nanometer and sub-nanometer scales. The AP-labeled nanoparticle concentration measurement can then be directly used to quantitatively analyze the biomolecular concentration. Micro-droplets are mono-dispersed micro-reactors that can be used to encapsulate and detect AP-labeled nanoparticles. Micro-droplets include both empty micro-droplets and fluorescent micro-droplets, while fluorescent micro-droplets are generated from the fluorescence reaction between the APs adhering to a single nanoparticle and corresponding fluorogenic substrates within droplets. By detecting micro-droplets and calculating the proportion of fluorescent micro-droplets to the overall micro-droplets, we can calculate the AP-labeled nanoparticle concentration. The proposed micro-droplet detection method includes the following steps: (1 Gaussian filtering to remove the noise of overall fluorescent targets, (2 a contrast-limited, adaptive histogram equalization processing to enhance the contrast of weakly luminescent micro-droplets, (3 an red maximizing inter-class variance thresholding method (OTSU to segment the enhanced image for getting the binary map of the overall micro-droplets, (4 a circular Hough transform (CHT method to detect overall micro-droplets and (5 an intensity-mean-based thresholding segmentation method to extract the fluorescent micro-droplets. The experimental results of fluorescent micro-droplet images show that the average accuracy of our micro-droplet detection method is 0.9586; the average true positive rate is 0.9502; and the average false positive rate is 0.0073. The detection method can be successfully applied to measure AP-labeled nanoparticle concentration in fluorescence microscopy.

  14. Hollow-fiber micro-extraction combined with HPLC for the determination of sitagliptin in urine samples

    Directory of Open Access Journals (Sweden)

    Rezaee Raheme

    2015-01-01

    Full Text Available This study successfully developed a three-phase hollow-fiber liquid phase micro extraction coupled with high performance liquid chromatography for determination of trace levels of an anti-diabetic drug, sitagliptin (STG, in urine samples. Sitagliptin was extracted from 15 mL of the basic sample solution with a pH of 8.5 into an organic extracting solvent (n-octanol impregnated in the pores of a hollow fiber and then back extracted into an acidified aqueous solution in the lumen of the hollow fiber with a pH of 3. After extraction, 20 µL of the acceptor phase was injected into HPLC. In order to obtain high extraction efficiency, the parameters affecting the HF-LPME including pH of the source and receiving phases, type of organic phase, ionic strength, stirring rate, extraction time, the volume ratio of donor phase to acceptor phase and temperature were studied and optimized. Under the optimized conditions, enrichment factors up to 88 were achieved and the relative standard deviation of the method was in the range of 3 % to 6%. The results indicated that HF-LPME method has an excellent clean-up capacity and a high preconcentration factor and can serve as a simple and sensitive method for monitoring the drug in the urine samples.

  15. Weighing environmental advantages and disadvantages of advanced wastewater treatment of micro-pollutants using environmental life cycle assessment

    DEFF Research Database (Denmark)

    Wenzel, Henrik; Larsen, Henrik Fred; Clauson-Kaas, Jes

    2008-01-01

    Much research and development effort is directed towards advances in municipal wastewater treatment aiming at reducing the effluent content of micro-pollutants and pathogens. The objective is to further reduce the eco-toxicity, hormone effects and pathogenic effects of the effluent. Such further ...

  16. Weighing environmental advantages and disadvantages of advanced wastewater treatment of micro-pollutants using environmental life cycle assessment

    DEFF Research Database (Denmark)

    Wenzel, Henrik; Larsen, Henrik Fred; Clauson-Kaas, Jes

    2007-01-01

    Much research and development effort is directed towards advances in municipal wastewater treatment aiming at reducing the effluent content of micro-pollutants and pathogens. The objective is to further reduce the eco-toxicity, hormone effects and pathogenic effects of the effluent. Such further ...

  17. Accuracy of micro four-point probe measurements on inhomogeneous samples: A probe spacing dependence study

    DEFF Research Database (Denmark)

    Wang, Fei; Petersen, Dirch Hjorth; Østerberg, Frederik Westergaard

    2009-01-01

    In this paper, we discuss a probe spacing dependence study in order to estimate the accuracy of micro four-point probe measurements on inhomogeneous samples. Based on sensitivity calculations, both sheet resistance and Hall effect measurements are studied for samples (e.g. laser annealed samples...... the probe spacing is smaller than 1/40 of the variation wavelength, micro four-point probes can provide an accurate record of local properties with less than 1% measurement error. All the calculations agree well with previous experimental results.......) with periodic variations of sheet resistance, sheet carrier density, and carrier mobility. With a variation wavelength of ¿, probe spacings from 0.0012 to 1002 have been applied to characterize the local variations. The calculations show that the measurement error is highly dependent on the probe spacing. When...

  18. Plasma assisted nitriding for micro-texturing onto martensitic stainless steels*

    Directory of Open Access Journals (Sweden)

    Katoh Takahisa

    2015-01-01

    Full Text Available Micro-texturing method has grown up to be one of the most promising procedures to form micro-lines, micro-dots and micro-grooves onto the mold-die materials and to duplicate these micro-patterns onto metallic or polymer sheets via stamping or injection molding. This related application requires for large-area, fine micro-texturing onto the martensitic stainless steel mold-die materials. A new method other than laser-machining, micro-milling or micro-EDM is awaited for further advancement of this micro-texturing. In the present paper, a new micro-texturing method is developed on the basis of the plasma assisted nitriding to transform the two-dimensionally designed micro-patterns to the three dimensional micro-textures in the martensitic stainless steels. First, original patterns are printed onto the surface of stainless steel molds by using the dispenser or the ink-jet printer. Then, the masked mold is subjected to high density plasma nitriding; the un-masked surfaces are nitrided to have higher hardness, 1400 Hv than the matrix hardness, 200 Hv of stainless steels. This nitrided mold is further treated by sand-blasting to selectively remove the soft, masked surfaces. Finally, the micro-patterned martensitic stainless steel mold is fabricated as a tool to duplicate these micro-patterns onto the plastic materials by the injection molding.

  19. Discrimination method of large log-likelihood study in differential diagnosis of pulmonary diffuse mild micro-nodule

    International Nuclear Information System (INIS)

    Chen Budong; Ma Daqing; He Wen; Tang Hongqu; Qian Linxue; Zhou Ronglin

    2001-01-01

    Objective: To analyze HRCT and thin-slice CT scan findings in 150 patients with pulmonary diffuse mild micro-nodule, and to find the features with the purpose of identifying random micro-nodule, peri-lymphatic micro-nodule, and centrilobular micro-nodule. Methods: The useful features i 150 patients with pulmonary diffuse mild micro-nodule were translated into scores by means of discrimination method of large log-likelihood to identify the micro-nodular category. Results: The accuracy of diagnosis was 94.0% for random micro-nodule, 76.0% for peri-lymphatic micro-nodule, and 90.0% for centrilobular micro-nodule. Conclusion: HRCT and thin-slice CT scans were helpful in differential diagnosis of pulmonary diffuse mild micro-nodule. The discrimination method of large log-likelihood was propitious to diagnosis and differential diagnosis

  20. Design, fabrication, and evaluation of on-chip micro-supercapacitors

    Science.gov (United States)

    Beidaghi, Majid; Chen, Wei; Wang, Chunlei

    2011-06-01

    Development of miniaturized electronic systems has stimulated the demand for miniaturized power sources that can be integrated into such systems. Among the different micro power sources micro electrochemical energy storage and conversion devices are particularly attractive because of their high efficiency and relatively high energy density. Electrochemical micro-capacitors or micro-supercapacitors offer higher power density compared to micro-batteries and micro-fuel cells. In this paper, development of on-chip micro-supercapacitors based on interdigitated C-MEMS electrode microarrays is introduced. C-MEMS electrodes are employed both as electrode material for electric double layer capacitor (EDLC) or as three dimensional (3D) current collectors of EDLC or pseudo-capacitive materials. Recent advancements in fabrication methods of C-MEMS based micro-supercapacitors are discussed and electrochemical properties of C-MEMS electrodes and it composites are reviewed.

  1. Proceedings of the Workshop on Advanced Network and Technology Concepts for Mobile, Micro, and Personal Communications

    Science.gov (United States)

    Paul, Lori (Editor)

    1991-01-01

    The Workshop on Advanced Network and Technology Concepts for Mobile, Micro, and Personal Communications was held at NASA's JPL Laboratory on 30-31 May 1991. It provided a forum for reviewing the development of advanced network and technology concepts for turn-of-the-century telecommunications. The workshop was organized into three main categories: (1) Satellite-Based Networks (L-band, C-band, Ku-band, and Ka-band); (2) Terrestrial-Based Networks (cellular, CT2, PCN, GSM, and other networks); and (3) Hybrid Satellite/Terrestrial Networks. The proceedings contain presentation papers from each of the above categories.

  2. Recent advances in column switching sample preparation in bioanalysis.

    Science.gov (United States)

    Kataoka, Hiroyuki; Saito, Keita

    2012-04-01

    Column switching techniques, using two or more stationary phase columns, are useful for trace enrichment and online automated sample preparation. Target fractions from the first column are transferred online to a second column with different properties for further separation. Column switching techniques can be used to determine the analytes in a complex matrix by direct sample injection or by simple sample treatment. Online column switching sample preparation is usually performed in combination with HPLC or capillary electrophoresis. SPE or turbulent flow chromatography using a cartridge column and in-tube solid-phase microextraction using a capillary column have been developed for convenient column switching sample preparation. Furthermore, various micro-/nano-sample preparation devices using new polymer-coating materials have been developed to improve extraction efficiency. This review describes current developments and future trends in novel column switching sample preparation in bioanalysis, focusing on innovative column switching techniques using new extraction devices and materials.

  3. A multiscale method for modeling high-aspect-ratio micro/nano flows

    Science.gov (United States)

    Lockerby, Duncan; Borg, Matthew; Reese, Jason

    2012-11-01

    In this paper we present a new multiscale scheme for simulating micro/nano flows of high aspect ratio in the flow direction, e.g. within long ducts, tubes, or channels, of varying section. The scheme consists of applying a simple hydrodynamic description over the entire domain, and allocating micro sub-domains in very small ``slices'' of the channel. Every micro element is a molecular dynamics simulation (or other appropriate model, e.g., a direct simulation Monte Carlo method for micro-channel gas flows) over the local height of the channel/tube. The number of micro elements as well as their streamwise position is chosen to resolve the geometrical features of the macro channel. While there is no direct communication between individual micro elements, coupling occurs via an iterative imposition of mass and momentum-flux conservation on the macro scale. The greater the streamwise scale of the geometry, the more significant is the computational speed-up when compared to a full MD simulation. We test our new multiscale method on the case of a converging/diverging nanochannel conveying a simple Lennard-Jones liquid. We validate the results from our simulations by comparing them to a full MD simulation of the same test case. Supported by EPSRC Programme Grant, EP/I011927/1.

  4. A cryogenic tensile testing apparatus for micro-samples cooled by miniature pulse tube cryocooler

    International Nuclear Information System (INIS)

    Chen, L B; Liu, S X; Gu, K X; Zhou, Y; Wang, J J

    2015-01-01

    This paper introduces a cryogenic tensile testing apparatus for micro-samples cooled by a miniature pulse tube cryocooler. At present, tensile tests are widely applied to measure the mechanical properties of materials; most of the cryogenic tensile testing apparatus are designed for samples with standard sizes, while for non-standard size samples, especially for microsamples, the tensile testing cannot be conducted. The general approach to cool down the specimens for tensile testing is by using of liquid nitrogen or liquid helium, which is not convenient: it is difficult to keep the temperature of the specimens at an arbitrary set point precisely, besides, in some occasions, liquid nitrogen, especially liquid helium, is not easily available. To overcome these limitations, a cryogenic tensile testing apparatus cooled by a high frequency pulse tube cryocooler has been designed, built and tested. The operating temperatures of the developed tensile testing apparatus cover from 20 K to room temperature with a controlling precision of ±10 mK. The apparatus configurations, the methods of operation and some cooling performance will be described in this paper. (paper)

  5. MicroRNAs in large herpesvirus DNA genomes: recent advances.

    Science.gov (United States)

    Sorel, Océane; Dewals, Benjamin G

    2016-08-01

    MicroRNAs (miRNAs) are small non-coding RNAs (ncRNAs) that regulate gene expression. They alter mRNA translation through base-pair complementarity, leading to regulation of genes during both physiological and pathological processes. Viruses have evolved mechanisms to take advantage of the host cells to multiply and/or persist over the lifetime of the host. Herpesviridae are a large family of double-stranded DNA viruses that are associated with a number of important diseases, including lymphoproliferative diseases. Herpesviruses establish lifelong latent infections through modulation of the interface between the virus and its host. A number of reports have identified miRNAs in a very large number of human and animal herpesviruses suggesting that these short non-coding transcripts could play essential roles in herpesvirus biology. This review will specifically focus on the recent advances on the functions of herpesvirus miRNAs in infection and pathogenesis.

  6. High temperature x-ray micro-tomography

    Energy Technology Data Exchange (ETDEWEB)

    MacDowell, Alastair A., E-mail: aamacdowell@lbl.gov; Barnard, Harold; Parkinson, Dilworth Y.; Gludovatz, Bernd [Lawrence Berkeley National Lab., Berkeley, CA 94720 (United States); Haboub, Abdel [Lawrence Berkeley National Lab., Berkeley, CA 94720 (United States); current –Lincoln Univ., Jefferson City, Missouri, 65101 (United States); Larson, Natalie; Zok, Frank [University California Santa Barbara, Santa Barbara CA 93106 (United States); Panerai, Francesco; Mansour, Nagi N. [NASA Ames Research Centre, Moffett Field, CA, 94035 (United States); Bale, Hrishikesh [University California Berkeley, Berkeley, CA 94720 (United States); current - Carl Zeiss X-ray Microscopy, 4385 Hopyard Rd #100, Pleasanton, CA 94588 (United States); Acevedo, Claire [Lawrence Berkeley National Lab., Berkeley, CA 94720 (United States); University California San Francisco, San Francisco, CA 94143 (United States); Liu, Dong [University of Bristol, Bristol BS8 1TH (United Kingdom); Ritchie, Robert O. [Lawrence Berkeley National Lab., Berkeley, CA 94720 (United States); University California Berkeley, Berkeley, CA 94720 (United States)

    2016-07-27

    There is increasing demand for 3D micro-scale time-resolved imaging of samples in realistic - and in many cases extreme environments. The data is used to understand material response, validate and refine computational models which, in turn, can be used to reduce development time for new materials and processes. Here we present the results of high temperature experiments carried out at the x-ray micro-tomography beamline 8.3.2 at the Advanced Light Source. The themes involve material failure and processing at temperatures up to 1750°C. The experimental configurations required to achieve the requisite conditions for imaging are described, with examples of ceramic matrix composites, spacecraft ablative heat shields and nuclear reactor core Gilsocarbon graphite.

  7. Realization of size controllable graphene micro/nanogap with a micro/nanowire mask method for organic field-effect transistors

    DEFF Research Database (Denmark)

    Liao, Zhiyu; Wan, Qing; Liu, Huixuan

    2011-01-01

    with the graphene micro/nanogap bottom electrodes. The ultrathin thickness of the graphene, combined with its good compatibility with organic semiconductors, and high electrical conductivity produced high-performance CuPc film device with mobility at 0.053 cm(2)/Vs and on/off ratio at 10(5), showing promising......A size controllable graphene micro/nanogap fabrication method using micro/nanowire as mask is presented. The gap dimension can be adjusted by the diameter of the mask wire. As a typical application, copper phthalocyanine (CuPc) film organic field-effect transistors (OFETs) were fabricated...

  8. Status Report on the Development of Micro-Scheduling Software for the Advanced Outage Control Center Project

    Energy Technology Data Exchange (ETDEWEB)

    Germain, Shawn St. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Thomas, Kenneth [Idaho National Lab. (INL), Idaho Falls, ID (United States); Farris, Ronald [Idaho National Lab. (INL), Idaho Falls, ID (United States); Joe, Jeffrey [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2014-09-01

    The long-term viability of existing nuclear power plants (NPPs) in the United States (U.S.) is dependent upon a number of factors, including maintaining high capacity factors, maintaining nuclear safety, and reducing operating costs, particularly those associated with refueling outages. Refueling outages typically take 20-30 days, and for existing light water NPPs in the U.S., the reactor cannot be in operation during the outage. Furthermore, given that many NPPs generate between $1-1.5 million/day in revenue when in operation, there is considerable interest in shortening the length of refueling outages. Yet, refueling outages are highly complex operations, involving multiple concurrent and dependent activities that are difficult to coordinate. Finding ways to improve refueling outage performance while maintaining nuclear safety has proven to be difficult. The Advanced Outage Control Center project is a research and development (R&D) demonstration activity under the Light Water Reactor Sustainability (LWRS) Program. LWRS is a R&D program which works with industry R&D programs to establish technical foundations for the licensing and managing of long-term, safe, and economical operation of current NPPs. The Advanced Outage Control Center project has the goal of improving the management of commercial NPP refueling outages. To accomplish this goal, this INL R&D project is developing an advanced outage control center (OCC) that is specifically designed to maximize the usefulness of communication and collaboration technologies for outage coordination and problem resolution activities. This report describes specific recent efforts to develop a capability called outage Micro-Scheduling. Micro-Scheduling is the ability to allocate and schedule outage support task resources on a sub-hour basis. Micro-Scheduling is the real-time fine-tuning of the outage schedule to react to the actual progress of the primary outage activities to ensure that support task resources are

  9. Thermoluminescence properties of micro and nano structure hydroxyapatite after gamma irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Shafaei, Mostafa; Ziaie, Farhood; Hajiloo, Nahid [Nuclear Science and Technology Research Institute, Tehran (Iran, Islamic Republic of). Radiation Application Research School

    2016-12-15

    The goal of this study is to compare the thermoluminescence properties of nano and micro structure hydroxyapatite. Nano structure hydroxyapatite was synthesized via hydrolysis method, while the micro structure one was from Merck Company. X-ray diffraction and fourier transform infrared spectroscopy were used to determine the crystal structure and chemical composition of the hydroxyapatite samples. Particles sizes of each sample were estimated using Scherer equation and transmission electron microscopy system. Thermoluminescence properties of the samples were investigated under gamma irradiation. The glow curves of micro and nano structure samples show a peak at 150 C and 200 C, respectively. Thermoluminescence responses of both the samples were linear in the range of 25 - 1 000 Gy where, nano structure sample show a greater slope and stronger linearity in comparison to the micro sample. The results show that the thermoluminescence response of micro sample faded rapidly in comparison to the nano sample due to the existence of the peak at higher temperature.

  10. Experimental and numerical investigation into micro-flow cytometer with 3-D hydrodynamic focusing effect and micro-weir structure.

    Science.gov (United States)

    Hou, Hui-Hsiung; Tsai, Chien-Hsiung; Fu, Lung-Ming; Yang, Ruey-Jen

    2009-07-01

    This study presents a novel 3-D hydrodynamic focusing technique for micro-flow cytometers. In the proposed approach, the sample stream is compressed initially in the horizontal direction by a set of sheath flows such that it is constrained to the central region of the microchannel and is then focused in the vertical direction by a second pair of sheath flows. Thereafter, the focused sample stream passes over a micro-weir structure positioned directly beneath an optical detection system to capture polystyrene beads fluorescent signal. The microchannel configuration and operational parameters are optimized by performing a series of numerical simulations. An experimental investigation is then performed using a micro-flow cytometer fabricated using conventional micro-electro-mechanical systems techniques and an isotropic wet etching method. The results indicate that the two sets of sheath flows successfully constrain the sample stream within a narrow, well-defined region of the microchannel. Furthermore, the micro-weir structure prompts the separation of a mixed sample of 5 and 10 microm polystyrene beads in the vertical direction and ensures that the beads flow through the detection region of the microchannel in a sequential fashion and can therefore be reliably detected and counted.

  11. MicroRNA7 expression in exhaled breath condensate of smokers with chronic obstructive pulmonary disease: A potential biomarker?

    OpenAIRE

    Nevine Abd Elfattah; R. Ali-Labib

    2017-01-01

    Rationale: The global burden of lung cancer is attributed to its poor outcome as it is usually discovered in an advanced stage therefore the constant search for screening protocols among the high risk groups like smokers and chronic obstructive pulmonary disease (COPD). Biomarker testing in exhaled breath condensate (EBC) samples is a simple inexpensive non invasive method. Many previous researches linked the dys-Regulation of microRNAs to the development of lung carcinogenesis. Consequently ...

  12. Micro-Sample Extraction System for In-Situ Missions to Planets, Planetary Satellites, and Primitive Bodies

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to develop a proof-of-concept Micro-Sample Extraction System (µSES) to enable microfluidic instruments, currently under development at NASA Goddard Space...

  13. Characterization and compensation of thermo-elastic instability of SWARM optical bench on Micro Advanced Stellar Compass attitude observations

    DEFF Research Database (Denmark)

    Herceg, Matija; Jørgensen, Peter Siegbjørn; Jørgensen, John Leif

    2017-01-01

    Launched into orbit on November 22, 2013, the Swarm constellation of three satellites precisely measures magnetic signal of the Earth. To ensure the high accuracy of magnetic observation by vector magnetometer (VFM), its inertial attitude is precisely determined by µASC (micro Advanced Stellar Co...

  14. The applicability of micro-filters produced by nuclear methods in the food industry

    International Nuclear Information System (INIS)

    Szabo, S.A.; Ember, G.

    1982-01-01

    Problems of the applicability in the food industry of micro-filters produced by nuclear methods are dealt with. Production methods of the polymeric micro-filters, their main characteristics as well as their most important application fields (breweries, dairies, alcoholic- and soft-drink plants, wine industry) are briefly reviewed. (author)

  15. Intelligent Operation and Maintenance of Micro-grid Technology and System Development

    Science.gov (United States)

    Fu, Ming; Song, Jinyan; Zhao, Jingtao; Du, Jian

    2018-01-01

    In order to achieve the micro-grid operation and management, Studying the micro-grid operation and maintenance knowledge base. Based on the advanced Petri net theory, the fault diagnosis model of micro-grid is established, and the intelligent diagnosis and analysis method of micro-grid fault is put forward. Based on the technology, the functional system and architecture of the intelligent operation and maintenance system of micro-grid are studied, and the microcomputer fault diagnosis function is introduced in detail. Finally, the system is deployed based on the micro-grid of a park, and the micro-grid fault diagnosis and analysis is carried out based on the micro-grid operation. The system operation and maintenance function interface is displayed, which verifies the correctness and reliability of the system.

  16. High sensitivity and selectivity in quantitative analysis of drugs in biological samples using 4-column multidimensional micro-UHPLC-MS enabling enhanced sample loading capacity.

    Science.gov (United States)

    de Vries, Ronald; Vereyken, Liesbeth; François, Isabelle; Dillen, Lieve; Vreeken, Rob J; Cuyckens, Filip

    2017-10-09

    Sensitivity is often a critical parameter in quantitative bioanalyses in drug development. For liquid-chromatography-based methods, sensitivity can be improved by reducing the column diameter, but practical sensitivity gains are limited by the reduced sample loading capacity on small internal diameter (I.D.) columns. We developed a set-up that has overcome these limitations in sample loading capacity. The set-up uses 4 columns with gradually decreasing column diameters along the flow-path (2.1 → 1 → 0.5 → 0.15 mm). Samples are pre-concentrated on-line on a 2.1 mm I.D. trapping column and back flushed to a 1 mm I.D. UHPLC analytical column and separated. The peak(s) of interest are transferred using heartcutting to a second trapping column (0.5 mm I.D.), which is back-flushed to a 0.15 mm I.D. micro-UHPLC analytical column for orthogonal separation. The proof of concept of the set-up was demonstrated by the simultaneous analysis of midazolam and 1'-hydroxy midazolam in plasma by injection of 80 μL of protein precipitated plasma. The 4-column funnel set-up proved to be robust and resulted in a 10-50 times better sensitivity compared to a trap-elute approach and 250-500 fold better compared to direct micro-UHPLC analysis. A lower limit of quantification of 100 fg/mL in plasma was obtained for both probe compounds. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Advances in Numerical Methods

    CERN Document Server

    Mastorakis, Nikos E

    2009-01-01

    Features contributions that are focused on significant aspects of current numerical methods and computational mathematics. This book carries chapters that advanced methods and various variations on known techniques that can solve difficult scientific problems efficiently.

  18. Recent Advances in the Control of Piezoelectric Actuators

    Directory of Open Access Journals (Sweden)

    Ziqiang Chi

    2014-11-01

    Full Text Available The micro/nano positioning field has made great progress towards enabling the advance of micro/nano technology. Micro/nano positioning stages actuated by piezoelectric actuators are the key devices in micro/nano manipulation. The control of piezoelectric actuators has emerged as a hot topic in recent years. Piezoelectric materials have inherent hysteresis and creep nonlinearity, which can reduce the accuracy of the manipulation, even causing the instability of the whole system. Remarkable efforts have been made to compensate for the nonlinearity of piezoelectric actuation through the mathematical modelling and control approaches. This paper provides a review of recent advances on the control of piezoelectric actuators. After a brief introduction of basic components of typical piezoelectric micro/nano positioning platforms, the working principle and modelling of piezoelectric actuators are outlined in this paper. This is followed with the major control method and recent progress is presented in detail. Finally, some open issues and future work on the control of piezoelectric actuators are extensively discussed.

  19. Misrepresenting random sampling? A systematic review of research papers in the Journal of Advanced Nursing.

    Science.gov (United States)

    Williamson, Graham R

    2003-11-01

    This paper discusses the theoretical limitations of the use of random sampling and probability theory in the production of a significance level (or P-value) in nursing research. Potential alternatives, in the form of randomization tests, are proposed. Research papers in nursing, medicine and psychology frequently misrepresent their statistical findings, as the P-values reported assume random sampling. In this systematic review of studies published between January 1995 and June 2002 in the Journal of Advanced Nursing, 89 (68%) studies broke this assumption because they used convenience samples or entire populations. As a result, some of the findings may be questionable. The key ideas of random sampling and probability theory for statistical testing (for generating a P-value) are outlined. The result of a systematic review of research papers published in the Journal of Advanced Nursing is then presented, showing how frequently random sampling appears to have been misrepresented. Useful alternative techniques that might overcome these limitations are then discussed. REVIEW LIMITATIONS: This review is limited in scope because it is applied to one journal, and so the findings cannot be generalized to other nursing journals or to nursing research in general. However, it is possible that other nursing journals are also publishing research articles based on the misrepresentation of random sampling. The review is also limited because in several of the articles the sampling method was not completely clearly stated, and in this circumstance a judgment has been made as to the sampling method employed, based on the indications given by author(s). Quantitative researchers in nursing should be very careful that the statistical techniques they use are appropriate for the design and sampling methods of their studies. If the techniques they employ are not appropriate, they run the risk of misinterpreting findings by using inappropriate, unrepresentative and biased samples.

  20. Determination of drugs in biological fluids by direct injection of samples for liquid-chromatographic analysis.

    Science.gov (United States)

    Mullett, Wayne M

    2007-03-10

    The analysis of drugs in various biological fluids is an important criterion for the determination of the physiological performance of a drug. After sampling of the biological fluid, the next step in the analytical process is sample preparation. The complexity of biological fluids adds to the challenge of direct determination of the drug by chromatographic analysis, therefore demanding a sample preparation step that is often time-consuming, tedious, and frequently overlooked. However, direct on-line injection methods offer the advantage of reducing sample preparation steps and enabling effective pre-concentration and clean-up of biological fluids. These procedures can be automated and therefore reduce the requirements for handling potentially infectious biomaterial, improve reproducibility, and minimize sample manipulations and potential contamination. The objective of this review is to present an overview of the existing literature with emphasis on advances in automated sample preparation methods for liquid-chromatographic methods. More specifically, this review concentrates on the use of direct injection techniques, such as restricted-access materials, turbulent-flow chromatography and other automated on-line solid-phase extraction (SPE) procedures. It also includes short overviews of emerging automated extraction-phase technologies, such as molecularly imprinted polymers, in-tube solid-phase micro-extraction, and micro-extraction in a packed syringe for a more selective extraction of analytes from complex samples, providing further improvements in the analysis of biological materials. Lastly, the outlook for these methods and potential new applications for these technologies are briefly discussed.

  1. Effect of dislocation pile-up on size-dependent yield strength in finite single-crystal micro-samples

    Energy Technology Data Exchange (ETDEWEB)

    Pan, Bo; Shibutani, Yoji, E-mail: sibutani@mech.eng.osaka-u.ac.jp [Department of Mechanical Engineering, Osaka University, Suita 565-0871 (Japan); Zhang, Xu [State Key Laboratory for Strength and Vibration of Mechanical Structures, School of Aerospace, Xi' an Jiaotong University, Xi' an 710049 (China); School of Mechanics and Engineering Science, Zhengzhou University, Zhengzhou 450001 (China); Shang, Fulin [State Key Laboratory for Strength and Vibration of Mechanical Structures, School of Aerospace, Xi' an Jiaotong University, Xi' an 710049 (China)

    2015-07-07

    Recent research has explained that the steeply increasing yield strength in metals depends on decreasing sample size. In this work, we derive a statistical physical model of the yield strength of finite single-crystal micro-pillars that depends on single-ended dislocation pile-up inside the micro-pillars. We show that this size effect can be explained almost completely by considering the stochastic lengths of the dislocation source and the dislocation pile-up length in the single-crystal micro-pillars. The Hall–Petch-type relation holds even in a microscale single-crystal, which is characterized by its dislocation source lengths. Our quantitative conclusions suggest that the number of dislocation sources and pile-ups are significant factors for the size effect. They also indicate that starvation of dislocation sources is another reason for the size effect. Moreover, we investigated the explicit relationship between the stacking fault energy and the dislocation “pile-up” effect inside the sample: materials with low stacking fault energy exhibit an obvious dislocation pile-up effect. Our proposed physical model predicts a sample strength that agrees well with experimental data, and our model can give a more precise prediction than the current single arm source model, especially for materials with low stacking fault energy.

  2. [Technological advances and micro-inflammation in dialysis patients].

    Science.gov (United States)

    Ferro, Giuseppe; Ravaglia, Fiammetta; Ferrari, Elisa; Romoli, Elena; Michelassi, Stefano; Caiani, David; Pizzarelli, Francesco

    2015-01-01

    As currently performed, on line hemodiafiltration reduces, but does not normalize, the micro-inflammation of uremic patients. Recent technological advances make it possible to further reduce the inflammation connected to the dialysis treatment. 
Short bacterial DNA fragments are pro-inflammatory and can be detected in the dialysis fluids. However, their determination is not currently within normal controls of the quality of the dialysate. The scenario may change once the analysis of these fragments yields reliable, inexpensive, quick and easy to evaluate the results. At variance with standard bicarbonate dialysate, Citrate dialysate induces far less inflammation both for the well-known anti-inflammatory effect of such buffer and also because it is completely acetate free, e.g. a definitely pro-inflammatory buffer. However, the extensive use of citrate dialysate in chronic dialysis is prevented because of concerns about its potential calcium lowering effect. In our view, high convective exchange on line hemodiafiltration performed with dialysate, whose sterility and a-pirogenicity is guaranteed by increasingly sophisticated controls and with citrate buffer whose safety is certified, can serve as the gold standard of dialysis treatments in future.

  3. Preparation, characterization and nonlinear absorption studies of cuprous oxide nanoclusters, micro-cubes and micro-particles

    Science.gov (United States)

    Sekhar, H.; Narayana Rao, D.

    2012-07-01

    Cuprous oxide nanoclusters, micro-cubes and micro-particles were successfully synthesized by reducing copper(II) salt with ascorbic acid in the presence of sodium hydroxide via a co-precipitation method. The X-ray diffraction and FTIR studies revealed that the formation of pure single-phase cubic. Raman and EPR spectral studies show the presence of CuO in as-synthesized powders of Cu2O. Transmission electron microscopy and field emission scanning electron microscopy data revealed that the morphology evolves from nanoclusters to micro-cubes and micro-particles by increasing the concentration of NaOH. Linear optical measurements show absorption peak maximum shifts towards red with changing morphology from nanoclusters to micro-cubes and micro-particles. The nonlinear optical properties were studied using open aperture Z-scan technique with 532 nm 6 ns laser pulses. Samples-exhibited both saturable as well as reverse saturable absorption. Due to confinement effects (enhanced band gap), we observed enhanced nonlinear absorption coefficient (β) in the case of nanoclusters compared to their micro-cubes and micro-particles.

  4. Toward cost-efficient sampling methods

    Science.gov (United States)

    Luo, Peng; Li, Yongli; Wu, Chong; Zhang, Guijie

    2015-09-01

    The sampling method has been paid much attention in the field of complex network in general and statistical physics in particular. This paper proposes two new sampling methods based on the idea that a small part of vertices with high node degree could possess the most structure information of a complex network. The two proposed sampling methods are efficient in sampling high degree nodes so that they would be useful even if the sampling rate is low, which means cost-efficient. The first new sampling method is developed on the basis of the widely used stratified random sampling (SRS) method and the second one improves the famous snowball sampling (SBS) method. In order to demonstrate the validity and accuracy of two new sampling methods, we compare them with the existing sampling methods in three commonly used simulation networks that are scale-free network, random network, small-world network, and also in two real networks. The experimental results illustrate that the two proposed sampling methods perform much better than the existing sampling methods in terms of achieving the true network structure characteristics reflected by clustering coefficient, Bonacich centrality and average path length, especially when the sampling rate is low.

  5. New approach to measure soil particulate organic matter in intact samples using X-ray computed micro-tomography

    Science.gov (United States)

    Kravchenko, Alexandra; Negassa, Wakene; Guber, Andrey; Schmidt, Sonja

    2014-05-01

    Particulate soil organic matter (POM) is biologically and chemically active fraction of soil organic matter. It is a source of many agricultural and ecological benefits, among which are POM's contribution to C sequestration. Most of conventional research methods for studying organic matter dynamics involve measurements conducted on pre-processed i.e., ground and sieved soil samples. Unfortunately, grinding and sieving completely destroys soil structure, the component crucial for soil functioning and C protection. Importance of a better understanding of the role of soil structure and of the physical protection that it provides to soil C cannot be overstated; and analysis of quantities, characteristics, and decomposition rates of POM in soil samples with intact structure is among the key elements of gaining such understanding. However, a marked difficulty hindering the progress in such analyses is a lack of tools for identification and quantitative analysis of POM in intact soil samples. Recent advancement in applications of X-ray computed micro-tomography (μ-CT) to soil science has given an opportunity to conduct such analyses. The objective of the current study is to develop a procedure for identification and quantitative characterization of POM within intact soil samples using X-ray μ-CT images and to test performance of the proposed procedure on a set of multiple intact soil macro-aggregates. We used 16 4-6 mm soil aggregates collected at 0-15 cm depth from a Typic Hapludalf soil at multiple field sites with diverse agricultural management history. The aggregates have been scanned at SIMBIOS Centre, Dundee, Scotland at 10 micron resolution. POM was determined from the aggregate images using the developed procedure. The procedure was based on combining image pre-processing steps with discriminant analysis classification. The first component of the procedure consisted of image pre-processing steps based on the range of gray values (GV) along with shape and size

  6. Micro-seismic imaging using a source function independent full waveform inversion method

    Science.gov (United States)

    Wang, Hanchen; Alkhalifah, Tariq

    2018-03-01

    At the heart of micro-seismic event measurements is the task to estimate the location of the source micro-seismic events, as well as their ignition times. The accuracy of locating the sources is highly dependent on the velocity model. On the other hand, the conventional micro-seismic source locating methods require, in many cases manual picking of traveltime arrivals, which do not only lead to manual effort and human interaction, but also prone to errors. Using full waveform inversion (FWI) to locate and image micro-seismic events allows for an automatic process (free of picking) that utilizes the full wavefield. However, full waveform inversion of micro-seismic events faces incredible nonlinearity due to the unknown source locations (space) and functions (time). We developed a source function independent full waveform inversion of micro-seismic events to invert for the source image, source function and the velocity model. It is based on convolving reference traces with these observed and modeled to mitigate the effect of an unknown source ignition time. The adjoint-state method is used to derive the gradient for the source image, source function and velocity updates. The extended image for the source wavelet in Z axis is extracted to check the accuracy of the inverted source image and velocity model. Also, angle gathers is calculated to assess the quality of the long wavelength component of the velocity model. By inverting for the source image, source wavelet and the velocity model simultaneously, the proposed method produces good estimates of the source location, ignition time and the background velocity for synthetic examples used here, like those corresponding to the Marmousi model and the SEG/EAGE overthrust model.

  7. Micro-seismic imaging using a source function independent full waveform inversion method

    KAUST Repository

    Wang, Hanchen

    2018-03-26

    At the heart of micro-seismic event measurements is the task to estimate the location of the source micro-seismic events, as well as their ignition times. The accuracy of locating the sources is highly dependent on the velocity model. On the other hand, the conventional micro-seismic source locating methods require, in many cases manual picking of traveltime arrivals, which do not only lead to manual effort and human interaction, but also prone to errors. Using full waveform inversion (FWI) to locate and image micro-seismic events allows for an automatic process (free of picking) that utilizes the full wavefield. However, full waveform inversion of micro-seismic events faces incredible nonlinearity due to the unknown source locations (space) and functions (time). We developed a source function independent full waveform inversion of micro-seismic events to invert for the source image, source function and the velocity model. It is based on convolving reference traces with these observed and modeled to mitigate the effect of an unknown source ignition time. The adjoint-state method is used to derive the gradient for the source image, source function and velocity updates. The extended image for the source wavelet in Z axis is extracted to check the accuracy of the inverted source image and velocity model. Also, angle gathers is calculated to assess the quality of the long wavelength component of the velocity model. By inverting for the source image, source wavelet and the velocity model simultaneously, the proposed method produces good estimates of the source location, ignition time and the background velocity for synthetic examples used here, like those corresponding to the Marmousi model and the SEG/EAGE overthrust model.

  8. Cone-shaped membrane liquid phase micro extraction

    International Nuclear Information System (INIS)

    Hong, Heng See; Sanagi, M.M.; Ibrahim, W.A.W.; Naim, A.A.

    2008-01-01

    A novel sample pre-treatment technique termed cone-shaped membrane liquid phase micro extraction (CSM-LPME) was developed and combined with micro-liquid chromatography (micro-LC) for the determination of selected pesticides in water samples. Several important extraction parameters such as types of extraction solvent, agitation rate, pH value, total exposure time and effect of salt and humic acids were investigated and optimized. Enrichment factors of >50 folds were easily achieved within 20 min of extraction. The new developed method demonstrated an excellent performance in terms of speed, cost effectiveness, reproducibility, as well as exceptional low detection limits. Current work provides a great interest to further investigate on the applicability of the CSM-LPME technique in analytical chemistry and explores the possibility of replacing conventional extraction techniques such as soxhlet, solid phase extraction (SPE) and solid phase micro extraction (SPME). (author)

  9. A Simplified Control Method for Tie-Line Power of DC Micro-Grid

    Directory of Open Access Journals (Sweden)

    Yanbo Che

    2018-04-01

    Full Text Available Compared with the AC micro-grid, the DC micro-grid has low energy loss and no issues of frequency stability, which makes it more accessible for distributed energy. Thus, the DC micro-grid has good potential for development. A variety of renewable energy is included in the DC micro-grid, which is easily affected by the environment, causing fluctuation of the DC voltage. For grid-connected DC micro-grid with droop control strategy, the tie-line power is affected by fluctuations in the DC voltage, which sets higher requirements for coordinated control of the DC micro-grid. This paper presents a simplified control method to maintain a constant tie-line power that is suitable for the DC micro-grid with the droop control strategy. By coordinating the designs of the droop control characteristics of generators, energy storage units and grid-connected inverter, a dead band is introduced to the droop control to improve the system performance. The tie-line power in the steady state is constant. When a large disturbance occurs, the AC power grid can provide power support to the micro-grid in time. The simulation example verifies the effectiveness of the proposed control strategy.

  10. Femtosecond laser micro-machined polyimide films for cell scaffold applications

    DEFF Research Database (Denmark)

    Antanavičiute, Ieva; Šimatonis, Linas; Ulčinas, Orestas

    2018-01-01

    of commercially available 12.7 and 25.4μm thickness polyimide (PI) film was applied. Mechanical properties of the fabricated scaffolds, i.e. arrays of differently spaced holes, were examined via custom-built uniaxial micro-tensile testing and finite element method simulations. We demonstrate that experimental...... micro-tensile testing results could be numerically simulated and explained by two-material model, assuming that 2-6μm width rings around the holes possessed up to five times higher Young's modulus and yield stress compared with the rest of the laser intacted PI film areas of 'dog-bone'-shaped specimens......Engineering of sophisticated synthetic 3D scaffolds that allow controlling behaviour and location of the cells requires advanced micro/nano-fabrication techniques. Ultrafast laser micro-machining employing a 1030-nm wavelength Yb:KGW femtosecond laser and a micro-fabrication workstation for micro-machining...

  11. Advances in lasers and optical micro-nano-systems

    Science.gov (United States)

    Laurell, F.; Fazio, E.

    2010-09-01

    manipulation of the writing-reading optical beam can push holography toward storages at higher data densities, as presented by Norihiko Ishii et al (Wavefront compensation method using novel index in holographic data storage). Along a similar direction Furlan et al describe a very innovative technique for producing optical traps using novel Devil micro-lenses (Volumetric multiple optical traps produced by Devil's lenses). Vynnyk et al presented an interesting application of electron microscopy for monitoring sub-micrometric structures in 3D configurations (3D-measurement with the stereo scanning electron microscope on sub-micrometer structure). Finally, S. Rao et al present two interesting papers on integrated structures compatible with silicon technology: one describes the realisation of low-loss waveguides using amorphous silicon, a relatively novel material with many applications in very different domains (Low-loss amorphous silicon waveguid! es grown by PECVD on indium tin oxide), and one on the realisation of a electrically drivable device with affective compatibility with CMOS technology (Electro-optical modulating multistack device based on the CMOS-compatible technology of amorphous silicon). We hope that this special issue of the Journal of the European Optical Society will reflect the interest of the European Scientific Community toward these fundamental and applied topics and will demonstrate to readers some of the actual directions of research. We express our full appreciation to the authors that participated to this initiative which acts only as a primer for the vast amount of work now being undertaken in laser physics and applications in micro- and nano-systems. We would like to give a special thank to the paper reviewers for their important role in the paper selection process and all the journal staff for their very professional support, dedication and energy, which made this special issue feasible.

  12. Microscopy of biological sample through advanced diffractive optics from visible to X-ray wavelength regime.

    Science.gov (United States)

    Di Fabrizio, Enzo; Cojoc, Dan; Emiliani, Valentina; Cabrini, Stefano; Coppey-Moisan, Maite; Ferrari, Enrico; Garbin, Valeria; Altissimo, Matteo

    2004-11-01

    The aim of this report is to demonstrate a unified version of microscopy through the use of advanced diffractive optics. The unified scheme derives from the technical possibility of realizing front wave engineering in a wide range of electromagnetic spectrum. The unified treatment is realized through the design and nanofabrication of phase diffractive elements (PDE) through which wave front beam shaping is obtained. In particular, we will show applications, by using biological samples, ranging from micromanipulation using optical tweezers to X-ray differential interference contrast (DIC) microscopy combined with X-ray fluorescence. We report some details on the design and physical implementation of diffractive elements that besides focusing also perform other optical functions: beam splitting, beam intensity, and phase redistribution or mode conversion. Laser beam splitting is used for multiple trapping and independent manipulation of micro-beads surrounding a cell as an array of tweezers and for arraying and sorting microscopic size biological samples. Another application is the Gauss to Laguerre-Gauss mode conversion, which allows for trapping and transfering orbital angular momentum of light to micro-particles immersed in a fluid. These experiments are performed in an inverted optical microscope coupled with an infrared laser beam and a spatial light modulator for diffractive optics implementation. High-resolution optics, fabricated by means of e-beam lithography, are demonstrated to control the intensity and the phase of the sheared beams in x-ray DIC microscopy. DIC experiments with phase objects reveal a dramatic increase in image contrast compared to bright-field x-ray microscopy. Besides the topographic information, fluorescence allows detection of certain chemical elements (Cl, P, Sc, K) in the same setup, by changing the photon energy of the x-ray beam. (c) 2005 Wiley-Liss, Inc.

  13. Application of combined micro-proton-induced X-ray emission and micro-synchrotron radiation X-ray fluorescence techniques for the characterization of impact materials around Barringer Meteor Crater

    Energy Technology Data Exchange (ETDEWEB)

    Uzonyi, I. [Institute of Nuclear Research of the Hungarian Academy of Sciences, Department of Electrostatic Accelerators, H-4026 Debrecen, Bem ter 18/C (Hungary)]. E-mail: uzonyi@atomki.hu; Szoeor, Gy. [Department of Mineralogy and Geology, University of Debrecen, H-4010 Debrecen, Egyetem ter 1 (Hungary); Vekemans, B. [Department of Chemistry, University of Antwerpen (UIA) Universiteitsplein 1, B-2610 Wilrijk (Belgium); Vincze, L. [Department of Chemistry, University of Antwerpen (UIA) Universiteitsplein 1, B-2610 Wilrijk (Belgium); Rozsa, P. [Department of Mineralogy and Geology, University of Debrecen, H-4010 Debrecen, Egyetem ter 1 (Hungary); Szabo, Gy. [Institute of Nuclear Research of the Hungarian Academy of Sciences, Department of Electrostatic Accelerators, H-4026 Debrecen, Bem ter 18/C (Hungary); Somogyi, A. [ID22, ESRF, 6 rue Jules Horowitz, BP 220, F-38043 Grenoble Cedex (France); Adams, F. [Department of Chemistry, University of Antwerpen (UIA) Universiteitsplein 1, B-2610 Wilrijk (Belgium); Kiss, A.Z. [Institute of Nuclear Research of the Hungarian Academy of Sciences, Department of Electrostatic Accelerators, H-4026 Debrecen, Bem ter 18/C (Hungary)

    2004-10-08

    A combined micro-PIXE and micro-SRXRF method has been used for the characterization of impact materials collected at the well-known Barringer Meteor Crater. Elemental maps were recorded and concentrations were determined by micro-PIXE method for the major constituents of samples. Micro-SRXRF technique was used for the complementary measurement of medium and high atomic number elements, especially the siderophilic ones. Altogether, approximately 40 elements were analyzed. These results elucidate many steps of the formation mechanism of the various impact-metamorphosed objects.

  14. High Throughput qPCR Expression Profiling of Circulating MicroRNAs Reveals Minimal Sex- and Sample Timing-Related Variation in Plasma of Healthy Volunteers.

    Directory of Open Access Journals (Sweden)

    Catherine Mooney

    Full Text Available MicroRNAs are a class of small non-coding RNA that regulate gene expression at a post-transcriptional level. MicroRNAs have been identified in various body fluids under normal conditions and their stability as well as their dysregulation in disease opens up a new field for biomarker study. However, diurnal and day-to-day variation in plasma microRNA levels, and differential regulation between males and females, may affect biomarker stability. A QuantStudio 12K Flex Real-Time PCR System was used to profile plasma microRNA levels using OpenArray in male and female healthy volunteers, in the morning and afternoon, and at four time points over a one month period. Using this system we were able to run four OpenArray plates in a single run, the equivalent of 32 traditional 384-well qPCR plates or 12,000 data points. Up to 754 microRNAs can be identified in a single plasma sample in under two hours. 108 individual microRNAs were identified in at least 80% of all our samples which compares favourably with other reports of microRNA profiles in serum or plasma in healthy adults. Many of these microRNAs, including miR-16-5p, miR-17-5p, miR-19a-3p, miR-24-3p, miR-30c-5p, miR-191-5p, miR-223-3p and miR-451a are highly expressed and consistent with previous studies using other platforms. Overall, microRNA levels were very consistent between individuals, males and females, and time points and we did not detect significant differences in levels of microRNAs. These results suggest the suitability of this platform for microRNA profiling and biomarker discovery and suggest minimal confounding influence of sex or sample timing. However, the platform has not been subjected to rigorous validation which must be demonstrated in future biomarker studies where large differences may exist between disease and control samples.

  15. Cross disease analysis of co-functional microRNA pairs on a reconstructed network of disease-gene-microRNA tripartite.

    Science.gov (United States)

    Peng, Hui; Lan, Chaowang; Zheng, Yi; Hutvagner, Gyorgy; Tao, Dacheng; Li, Jinyan

    2017-03-24

    MicroRNAs always function cooperatively in their regulation of gene expression. Dysfunctions of these co-functional microRNAs can play significant roles in disease development. We are interested in those multi-disease associated co-functional microRNAs that regulate their common dysfunctional target genes cooperatively in the development of multiple diseases. The research is potentially useful for human disease studies at the transcriptional level and for the study of multi-purpose microRNA therapeutics. We designed a computational method to detect multi-disease associated co-functional microRNA pairs and conducted cross disease analysis on a reconstructed disease-gene-microRNA (DGR) tripartite network. The construction of the DGR tripartite network is by the integration of newly predicted disease-microRNA associations with those relationships of diseases, microRNAs and genes maintained by existing databases. The prediction method uses a set of reliable negative samples of disease-microRNA association and a pre-computed kernel matrix instead of kernel functions. From this reconstructed DGR tripartite network, multi-disease associated co-functional microRNA pairs are detected together with their common dysfunctional target genes and ranked by a novel scoring method. We also conducted proof-of-concept case studies on cancer-related co-functional microRNA pairs as well as on non-cancer disease-related microRNA pairs. With the prioritization of the co-functional microRNAs that relate to a series of diseases, we found that the co-function phenomenon is not unusual. We also confirmed that the regulation of the microRNAs for the development of cancers is more complex and have more unique properties than those of non-cancer diseases.

  16. Degradation Analysis of NBR and Epichlorohydrin Rubber by New Micro Analysis Method

    Science.gov (United States)

    Katoh, Hisao; Kamoto, Ritsu; Murata, Jun

    The degradation analysis of NBR and Epichlorohydrin rubber was carried out by infrared micro spectroscopy (μ-IR) and micro sampling mass spectrometry (μ-MS) which gives information on the scission and crosslinking of rubber molecules. Samples were prepared by three different treatments, heat as well as ultra violet (UV) and electron beam (EB) irradiations. It was found for NBR vulcanizates that the heat treatment induced the oxidation, scission and crosslinking of rubber molecules. By the UV treatment, chain scission and crosslinking accompanied by a slight oxidation were induced. The EB treatment enhanced the crosslinking, however, the extent of oxidation was negligible. For Epichlorohydrin rubber vulcanizates, the heat treatment accelerated chain scission rather than crosslinking. On the other hand, the oxidation and crosslinking were induced by the UV and EB treatments.

  17. Differential expression analysis of balding and nonbalding dermal papilla microRNAs in male pattern baldness with a microRNA amplification profiling method.

    Science.gov (United States)

    Goodarzi, H R; Abbasi, A; Saffari, M; Fazelzadeh Haghighi, M; Tabei, M B; Noori Daloii, M R

    2012-05-01

      Male pattern baldness or androgenetic alopecia is a common disorder affecting almost 50% of men throughout their lifetime, with androgens and genetics having significant contributing aetiologies. In contrast to the positive regulatory effect of androgens on body hair growth, they are thought to alter scalp hair follicle behaviour pathophysiologically, leading to male pattern baldness. However, the exact mechanisms of this paradoxical action have not yet been elucidated. The role of microRNAs, a novel group of noncoding RNAs impacting almost every aspect of biology, health and human diseases, has been documented in hair follicle formation. In addition, their deregulation in cancer of the prostate, a target organ of androgens, has also been well established. To investigate the possible contribution of microRNAs in the pathophysiology of male pattern baldness. We initially screened microRNA expression profiles of balding and nonbalding hair follicle papillae with a sensitive microRNA cloning method, microRNA amplification profiling, and statistically analysed significant differentially expressed microRNAs in balding relative to nonbalding dermal papillae, with real-time polymerase chain reaction as a confirmatory method to quantify expression in eight individuals affected with the disorder.   We detected the significant upregulation of miR-221, miR-125b, miR-106a and miR-410 in balding papilla cells.   We found four microRNAs that could participate in the pathogenesis of male pattern baldness. Regarding the strong therapeutic potential of microRNAs and the easy accessibility of hair follicles for gene therapy, microRNAs are possible candidates for a new generation of revolutionary treatments. © 2011 The Authors. BJD © 2011 British Association of Dermatologists.

  18. Pore formation during dehydration of a polycrystalline gypsum sample observed and quantified in a time-series synchrotron X-ray micro-tomography experiment

    Directory of Open Access Journals (Sweden)

    F. Fusseis

    2012-03-01

    Full Text Available We conducted an in-situ X-ray micro-computed tomography heating experiment at the Advanced Photon Source (USA to dehydrate an unconfined 2.3 mm diameter cylinder of Volterra Gypsum. We used a purpose-built X-ray transparent furnace to heat the sample to 388 K for a total of 310 min to acquire a three-dimensional time-series tomography dataset comprising nine time steps. The voxel size of 2.2 μm3 proved sufficient to pinpoint reaction initiation and the organization of drainage architecture in space and time.

    We observed that dehydration commences across a narrow front, which propagates from the margins to the centre of the sample in more than four hours. The advance of this front can be fitted with a square-root function, implying that the initiation of the reaction in the sample can be described as a diffusion process.

    Novel parallelized computer codes allow quantifying the geometry of the porosity and the drainage architecture from the very large tomographic datasets (20483 voxels in unprecedented detail. We determined position, volume, shape and orientation of each resolvable pore and tracked these properties over the duration of the experiment. We found that the pore-size distribution follows a power law. Pores tend to be anisotropic but rarely crack-shaped and have a preferred orientation, likely controlled by a pre-existing fabric in the sample. With on-going dehydration, pores coalesce into a single interconnected pore cluster that is connected to the surface of the sample cylinder and provides an effective drainage pathway.

    Our observations can be summarized in a model in which gypsum is stabilized by thermal expansion stresses and locally increased pore fluid pressures until the dehydration front approaches to within about 100 μm. Then, the internal stresses are released and dehydration happens efficiently, resulting in new pore space. Pressure release, the production of pores and the

  19. Pore formation during dehydration of a polycrystalline gypsum sample observed and quantified in a time-series synchrotron X-ray micro-tomography experiment

    Science.gov (United States)

    Fusseis, F.; Schrank, C.; Liu, J.; Karrech, A.; Llana-Fúnez, S.; Xiao, X.; Regenauer-Lieb, K.

    2012-03-01

    We conducted an in-situ X-ray micro-computed tomography heating experiment at the Advanced Photon Source (USA) to dehydrate an unconfined 2.3 mm diameter cylinder of Volterra Gypsum. We used a purpose-built X-ray transparent furnace to heat the sample to 388 K for a total of 310 min to acquire a three-dimensional time-series tomography dataset comprising nine time steps. The voxel size of 2.2 μm3 proved sufficient to pinpoint reaction initiation and the organization of drainage architecture in space and time. We observed that dehydration commences across a narrow front, which propagates from the margins to the centre of the sample in more than four hours. The advance of this front can be fitted with a square-root function, implying that the initiation of the reaction in the sample can be described as a diffusion process. Novel parallelized computer codes allow quantifying the geometry of the porosity and the drainage architecture from the very large tomographic datasets (20483 voxels) in unprecedented detail. We determined position, volume, shape and orientation of each resolvable pore and tracked these properties over the duration of the experiment. We found that the pore-size distribution follows a power law. Pores tend to be anisotropic but rarely crack-shaped and have a preferred orientation, likely controlled by a pre-existing fabric in the sample. With on-going dehydration, pores coalesce into a single interconnected pore cluster that is connected to the surface of the sample cylinder and provides an effective drainage pathway. Our observations can be summarized in a model in which gypsum is stabilized by thermal expansion stresses and locally increased pore fluid pressures until the dehydration front approaches to within about 100 μm. Then, the internal stresses are released and dehydration happens efficiently, resulting in new pore space. Pressure release, the production of pores and the advance of the front are coupled in a feedback loop.

  20. Nanostructured conducting molecularly imprinted polymer for selective extraction of salicylate from urine and serum samples by electrochemically controlled solid-phase micro-extraction

    Energy Technology Data Exchange (ETDEWEB)

    Ameli, Akram [Department of Chemistry, Faculty of Science, Tarbiat Modares University, P.O. Box 14115-175, Tehran (Iran, Islamic Republic of); Alizadeh, Naader, E-mail: alizaden@modares.ac.ir [Department of Chemistry, Faculty of Science, Tarbiat Modares University, P.O. Box 14115-175, Tehran (Iran, Islamic Republic of)

    2011-11-30

    Highlights: Black-Right-Pointing-Pointer Overoxidized polypyrrole templated with salicylate has been utilized as conducting molecular imprinted polymer for EC-SPME. Black-Right-Pointing-Pointer This first study reported on conducting molecular imprinted polymer was used to EC-SPME of salicylate. Black-Right-Pointing-Pointer Proposed method, is particularly effective in sample clean-up and selective monitoring of salicylate in physiological samples. - Abstract: Overoxidized polypyrrole (OPPy) films templated with salicylate (SA) have been utilized as conducting molecular imprinted polymers (CMIPs) for potential-induced selective solid-phase micro-extraction processes. Various important fabrication factors for controlling the performance of the OPPy films have been investigated using fluorescence spectrometry. Several key parameters such as applied potential for uptake, release, pH of uptake and release solution were varied to achieve the optimum micro-extraction procedure. The film template with SA exhibited excellent selectivity over some interference. The calibration graphs were linear in the ranges of 5 Multiplication-Sign 10{sup -8} to 5 Multiplication-Sign 10{sup -4} and 1.2 Multiplication-Sign 10{sup -6} to 5 Multiplication-Sign 10{sup -4} mol mL{sup -1} and the detection limit was 4 Multiplication-Sign 10{sup -8} mol L{sup -1}. The OPPy film as the solid-phase micro-extraction absorbent has been applied for the selective clean-up and quantification of trace amounts of SA from physiological samples. The results of scanning electron microscopy (SEM) have confirmed the nano-structure morphologies of the films.

  1. Nanostructured conducting molecularly imprinted polymer for selective extraction of salicylate from urine and serum samples by electrochemically controlled solid-phase micro-extraction

    International Nuclear Information System (INIS)

    Ameli, Akram; Alizadeh, Naader

    2011-01-01

    Highlights: ► Overoxidized polypyrrole templated with salicylate has been utilized as conducting molecular imprinted polymer for EC-SPME. ► This first study reported on conducting molecular imprinted polymer was used to EC-SPME of salicylate. ► Proposed method, is particularly effective in sample clean-up and selective monitoring of salicylate in physiological samples. - Abstract: Overoxidized polypyrrole (OPPy) films templated with salicylate (SA) have been utilized as conducting molecular imprinted polymers (CMIPs) for potential-induced selective solid-phase micro-extraction processes. Various important fabrication factors for controlling the performance of the OPPy films have been investigated using fluorescence spectrometry. Several key parameters such as applied potential for uptake, release, pH of uptake and release solution were varied to achieve the optimum micro-extraction procedure. The film template with SA exhibited excellent selectivity over some interference. The calibration graphs were linear in the ranges of 5 × 10 −8 to 5 × 10 −4 and 1.2 × 10 −6 to 5 × 10 −4 mol mL −1 and the detection limit was 4 × 10 −8 mol L −1 . The OPPy film as the solid-phase micro-extraction absorbent has been applied for the selective clean-up and quantification of trace amounts of SA from physiological samples. The results of scanning electron microscopy (SEM) have confirmed the nano-structure morphologies of the films.

  2. Computational methods for ab initio detection of microRNAs

    Directory of Open Access Journals (Sweden)

    Malik eYousef

    2012-10-01

    Full Text Available MicroRNAs are small RNA sequences of 18-24 nucleotides in length, which serve as templates to drive post transcriptional gene silencing. The canonical microRNA pathway starts with transcription from DNA and is followed by processing via the Microprocessor complex, yielding a hairpin structure. Which is then exported into the cytosol where it is processed by Dicer and then incorporated into the RNA induced silencing complex. All of these biogenesis steps add to the overall specificity of miRNA production and effect. Unfortunately, their modes of action are just beginning to be elucidated and therefore computational prediction algorithms cannot model the process but are usually forced to employ machine learning approaches. This work focuses on ab initio prediction methods throughout; and therefore homology-based miRNA detection methods are not discussed. Current ab initio prediction algorithms, their ties to data mining, and their prediction accuracy are detailed.

  3. Micro-CT analyses of historical bone samples presenting with osteomyelitis

    Energy Technology Data Exchange (ETDEWEB)

    Lamm, C.; Pietschmann, P. [Medical University Vienna (MUV), Department of Pathophysiology and Allergy Research, Center for Pathophysiology, Infectiology and Immunology, Vienna (Austria); Dockner, M.; Weber, G.W. [University of Vienna, Department of Anthropology, Vienna (Austria); University of Vienna, Core Facility for Micro-Computed Tomography, Vienna (Austria); Pospischek, B.; Winter, E.; Patzak, B. [Museum of Natural History (NHM), Collection of Anatomical Pathology in the Madhouse Tower, Vienna (Austria); Pretterklieber, M. [Medical University of Vienna (MUV), Department of Applied Anatomy, Vienna (Austria)

    2015-10-15

    Osteomyelitis is an inflammation of the bone marrow mainly caused by bacteria such as Staphylococcus aureus. It typically affects long bones, e.g. femora, tibiae and humeri. Recently micro-computed tomography (μCT) techniques offer the opportunity to investigate bone micro-architecture in great detail. Since there is no information on long bone microstructure in osteomyelitis, we studied historic bone samples with osteomyelitis by μCT. We investigated 23 femora of 22 individuals suffering from osteomyelitis provided by the Collection of Anatomical Pathology, Museum of Natural History, Vienna (average age 44 ±19 years); 9 femora from body donors made available by the Department of Applied Anatomy, Medical University of Vienna (age range, 56-102 years) were studied as controls. Bone microstructure was assessed by μCT VISCOM X 8060 II with a minimal resolution of 18 μm. In the osteomyelitic femora, most prominent alterations were seen in the cortical compartment. In 71.4 % of the individuals with osteomyelitis, cortical porosity occurred. 57.1 % of the individuals showed cortical thinning. In 42.9 % trabecularisation of cortical bone was observed. Osteomyelitis is associated with severe alterations of cortical bone structure otherwise typically observed at old age such as cortical porosity and cortical thinning. (orig.)

  4. Micro Engineering: Experiments conducted on the use of polymeric materials in micro injection moulding

    DEFF Research Database (Denmark)

    Griffiths, Christian; Tosello, Guido; Nestler, Joerg

    2008-01-01

    To advance micro injection moulding it is necessary to study systematically the factors affecting process and tooling reliability. This paper reviews the main findings of Cardiff Universities 4M and SEMOFS research in this field. In particular, the factors affecting the manufacturability of micro...

  5. Towards Cost-efficient Sampling Methods

    OpenAIRE

    Peng, Luo; Yongli, Li; Chong, Wu

    2014-01-01

    The sampling method has been paid much attention in the field of complex network in general and statistical physics in particular. This paper presents two new sampling methods based on the perspective that a small part of vertices with high node degree can possess the most structure information of a network. The two proposed sampling methods are efficient in sampling the nodes with high degree. The first new sampling method is improved on the basis of the stratified random sampling method and...

  6. Pulse electrochemical meso/micro/nano ultraprecision machining technology.

    Science.gov (United States)

    Lee, Jeong Min; Kim, Young Bin; Park, Jeong Woo

    2013-11-01

    This study demonstrated meso/micro/nano-ultraprecision machining through electrochemical reactions using intermittent DC pulses. The experiment focused on two machining methods: (1) pulse electrochemical polishing (PECP) of stainless steel, and (2) pulse electrochemical nano-patterning (PECNP) on a silicon (Si) surface, using atomic force microscopy (AFM) for fabrication. The dissolution reaction at the stainless steel surface following PECP produced a very clean, smooth workpiece. The advantages of the PECP process included improvements in corrosion resistance, deburring of the sample surface, and removal of hydrogen from the stainless steel surface as verified by time-of-flight secondary-ion mass spectrometry (TOF-SIMS). In PECNP, the electrochemical reaction generated within water molecules produced nanoscale oxide textures on a Si surface. Scanning probe microscopy (SPM) was used to evaluate nanoscale-pattern processing on a Si wafer surface produced by AFM-PECNP For both processes using pulse electrochemical reactions, three-dimensional (3-D) measurements and AFM were used to investigate the changes on the machined surfaces. Preliminary results indicated the potential for advancing surface polishing techniques and localized micro/nano-texturing technology using PECP and PECNP processes.

  7. Micro-system inertial sensing technology overview.

    Energy Technology Data Exchange (ETDEWEB)

    Allen, James Joe

    2009-02-01

    The purpose of this report is to provide an overview of Micro-System technology as it applies to inertial sensing. Transduction methods are reviewed with capacitance and piezoresistive being the most often used in COTS Micro-electro-mechanical system (MEMS) inertial sensors. Optical transduction is the most recent transduction method having significant impact on improving sensor resolution. A few other methods are motioned which are in a R&D status to hopefully allow MEMS inertial sensors to become viable as a navigation grade sensor. The accelerometer, gyroscope and gravity gradiometer are the type of inertial sensors which are reviewed in this report. Their method of operation and a sampling of COTS sensors and grade are reviewed as well.

  8. Mild chemical strategy to grow micro-roses and micro-woolen like arranged CuO nanosheets for high performance supercapacitors

    Science.gov (United States)

    Dubal, Deepak P.; Gund, Girish S.; Holze, Rudolf; Lokhande, Chandrakant D.

    2013-11-01

    The hierarchical structures of nanosheets, micro-roses and micro-woolen like CuO nanosheets were directly fabricated on stainless steel via surfactant-free and inexpensive chemical bath deposition (CBD) method. Further, these CuO nanostructures demonstrate excellent surface properties like uniform surface morphology, high surface area and uniform pore size distribution of CuO samples. The electrochemical properties of CuO nanostructures have been investigated by cyclic voltammetry, charge-discharge and electrochemical impedance spectroscopy techniques. The electrochemical studies of the CuO samples show obvious influence of surface properties on the pseudocapacitance performance. The maximum specific capacitances of nanosheets, micro-roses and micro-woolen like CuO nanosheets are found to be 303 Fg-1, 279 Fg-1 and 346 Fg-1, respectively at 5 mV s-1 scan rate. Further, the EIS analysis shows lower ESR value, high power performance, excellent rate as well as frequency response of micro-woolen like CuO sample. The Ragone plot ascertains better power and energy densities of all three CuO nanostructured samples than other electrical energy storage devices. The long-term cycling performance of CuO is examined at different scan rates and the morphology changes of the electrode materials were studied. Present investigation suggests the inexpensive CBD approach for fine-tuning surface properties of oxide materials for energy storage applications.

  9. Advanced Transport Operating System (ATOPS) color displays software description: MicroVAX system

    Science.gov (United States)

    Slominski, Christopher J.; Plyler, Valerie E.; Dickson, Richard W.

    1992-01-01

    This document describes the software created for the Display MicroVAX computer used for the Advanced Transport Operating Systems (ATOPS) project on the Transport Systems Research Vehicle (TSRV). The software delivery of February 27, 1991, known as the 'baseline display system', is the one described in this document. Throughout this publication, module descriptions are presented in a standardized format which contains module purpose, calling sequence, detailed description, and global references. The global references section includes subroutines, functions, and common variables referenced by a particular module. The system described supports the Research Flight Deck (RFD) of the TSRV. The RFD contains eight Cathode Ray Tubes (CRTs) which depict a Primary Flight Display, Navigation Display, System Warning Display, Takeoff Performance Monitoring System Display, and Engine Display.

  10. Identifying microRNA/mRNA dysregulations in ovarian cancer.

    Science.gov (United States)

    Miles, Gregory D; Seiler, Michael; Rodriguez, Lorna; Rajagopal, Gunaretnam; Bhanot, Gyan

    2012-03-27

    MicroRNAs are a class of noncoding RNA molecules that co-regulate the expression of multiple genes via mRNA transcript degradation or translation inhibition. Since they often target entire pathways, they may be better drug targets than genes or proteins. MicroRNAs are known to be dysregulated in many tumours and associated with aggressive or poor prognosis phenotypes. Since they regulate mRNA in a tissue specific manner, their functional mRNA targets are poorly understood. In previous work, we developed a method to identify direct mRNA targets of microRNA using patient matched microRNA/mRNA expression data using an anti-correlation signature. This method, applied to clear cell Renal Cell Carcinoma (ccRCC), revealed many new regulatory pathways compromised in ccRCC. In the present paper, we apply this method to identify dysregulated microRNA/mRNA mechanisms in ovarian cancer using data from The Cancer Genome Atlas (TCGA). TCGA Microarray data was normalized and samples whose class labels (tumour or normal) were ambiguous with respect to consensus ensemble K-Means clustering were removed. Significantly anti-correlated and correlated genes/microRNA differentially expressed between tumour and normal samples were identified. TargetScan was used to identify gene targets of microRNA. We identified novel microRNA/mRNA mechanisms in ovarian cancer. For example, the expression level of RAD51AP1 was found to be strongly anti-correlated with the expression of hsa-miR-140-3p, which was significantly down-regulated in the tumour samples. The anti-correlation signature was present separately in the tumour and normal samples, suggesting a direct causal dysregulation of RAD51AP1 by hsa-miR-140-3p in the ovary. Other pairs of potentially biological relevance include: hsa-miR-145/E2F3, hsa-miR-139-5p/TOP2A, and hsa-miR-133a/GCLC. We also identified sets of positively correlated microRNA/mRNA pairs that are most likely result from indirect regulatory mechanisms. Our findings identify

  11. Micro-educational reproduction

    DEFF Research Database (Denmark)

    Andrade, Stefan Bastholm; Thomsen, Jens Peter

    2017-01-01

    This study analyzes the persistence of educational inequality in advanced industrialized societies with expanding and differentiated education systems. Using Denmark as a case, we investigate changes in immobility patterns for cohorts born 1960–1981 and develop a new micro-educational classificat...... forms of reproduction. In addition, the micro-educational approach far better explains the immobility of sons than it explains that of daughters, revealing important gender differences in the immobility patterns for sons and daughters......., in particular for sons. We also find great variation in immobility for specific micro-educations within the university level. Studies of educational immobility would therefore benefit from paying attention to micro-educational classifications, because they capture patterns of multidimensional, disaggregated...

  12. Development of a novel non-contact inspection technique to detect micro cracks under the surface of a glass substrate by thermal stress-induced light scattering method

    Science.gov (United States)

    Sakata, Yoshitaro; Terasaki, Nao; Nonaka, Kazuhiro

    2017-05-01

    Fine polishing techniques, such as a chemical mechanical polishing treatment, are important techniques in glass substrate manufacturing. However, these techniques may cause micro cracks under the surface of glass substrates because they used mechanical friction. A stress-induced light scattering method (SILSM), which was combined with light scattering method and mechanical stress effects, was proposed for inspecting surfaces to detect polishing-induced micro cracks. However, in the conventional SILSM, samples need to be loaded with physical contact, and the loading point is invisible in transparent materials. Here, we introduced a novel non-contact SILSM using a heating device. A glass substrate was heated first, and then the light scattering intensity of micro cracks was detected by a cooled charge-couple device camera during the natural cooling process. Results clearly showed during the decreasing surface temperature of a glass substrate, appropriate thermal stress is generated for detecting micro cracks by using the SILSM and light scattering intensity from micro cracks changes. We confirmed that non-contact thermal SILSM (T-SILSM) can detect micro cracks under the surface of transparent materials.

  13. Human Milk MicroRNA and Total RNA Differ Depending on Milk Fractionation.

    Science.gov (United States)

    Alsaweed, Mohammed; Hepworth, Anna R; Lefèvre, Christophe; Hartmann, Peter E; Geddes, Donna T; Hassiotou, Foteini

    2015-10-01

    MicroRNA have been recently discovered in human milk signifying potentially important functions for both the lactating breast and the infant. Whilst human milk microRNA have started to be explored, little data exist on the evaluation of sample processing, and analysis to ensure that a full spectrum of microRNA can be obtained. Human milk comprises three main fractions: cells, skim milk, and lipids. Typically, the skim milk fraction has been measured in isolation despite evidence that the lipid fraction may contain more microRNA. This study aimed to standardize isolation of microRNA and total RNA from all three fractions of human milk to determine the most appropriate sampling and analysis procedure for future studies. Three different methods from eight commercially available kits were tested for their efficacy in extracting total RNA and microRNA from the lipid, skim, and cell fractions of human milk. Each fraction yielded different concentrations of RNA and microRNA, with the highest quantities found in the cell and lipid fractions, and the lowest in skim milk. The column-based phenol-free method was the most efficient extraction method for all three milk fractions. Two microRNAs were expressed and validated in the three milk fractions by qPCR using the three recommended extraction kits for each fraction. High expression levels were identified in the skim and lipid milk factions for these microRNAs. These results suggest that careful consideration of both the human milk sample preparation and extraction protocols should be made prior to embarking upon research in this area. © 2015 The Authors. Journal of Cellular Biochemistry Published by Wiley Periodicals, Inc.

  14. Development of a non-destructive micro-analytical method for stable carbon isotope analysis of transmission electron microscope (TEM) samples

    Energy Technology Data Exchange (ETDEWEB)

    Hode, Tomas [Department of Geology, Portland State University, Portland, P.O. Box 751, OR 97201 (United States)], E-mail: hode@pdx.edu; Kristiansson, Per; Elfman, Mikael [Division of Nuclear Physics, Department of Physics, Lund Institute of Technology, Lund University, P.O. Box 118, SE-221 00 Lund (Sweden); Hugo, Richard C.; Cady, Sherry L. [Department of Geology, Portland State University, Portland, P.O. Box 751, OR 97201 (United States)

    2009-10-01

    The biogenicity of ancient morphological microfossil-like objects can be established by linking morphological (e.g. cell remnants and extracellular polymeric matrix) and chemical (e.g. isotopes, biomarkers and biominerals) evidence indicative of microorganisms or microbial activity. We have developed a non-destructive micro-analytical ion beam system capable of measuring with high spatial resolution the stable carbon isotope ratios of thin samples used for transmission electron microscopy. The technique is based on elastic scattering of alpha particles with an energy of 2.751 MeV. At this energy the {sup 13}C cross section is enhanced relative to the pure Rutherford cross section for {sup 13}C, whereas the {sup 12}C cross section is reduced relative to its pure Rutherford cross section. Here we report the initial results of this experimental approach used to characterize ultramicrotomed sections of sulfur-embedded graphite and microbial cells.

  15. Micro-electromembrane extraction across free liquid membranes. Extractions of basic drugs from undiluted biological samples

    Czech Academy of Sciences Publication Activity Database

    Kubáň, Pavel; Boček, Petr

    2014-01-01

    Roč. 1337, Apr (2014), s. 32-39 ISSN 0021-9673 R&D Projects: GA ČR(CZ) GA13-05762S Institutional support: RVO:68081715 Keywords : micro-electromembrane extraction * free liquid membranes * biological samples Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 4.169, year: 2014

  16. Ionizing radiation as optimization method for aluminum detection from drinking water samples

    International Nuclear Information System (INIS)

    Bazante-Yamguish, Renata; Geraldo, Aurea Beatriz C.; Moura, Eduardo; Manzoli, Jose Eduardo

    2013-01-01

    The presence of organic compounds in water samples is often responsible for metal complexation; depending on the analytic method, the organic fraction may dissemble the evaluation of the real values of metal concentration. Pre-treatment of the samples is advised when organic compounds are interfering agents, and thus sample mineralization may be accomplished by several chemical and/or physical methods. Here, the ionizing radiation was used as an advanced oxidation process (AOP), for sample pre-treatment before the analytic determination of total and dissolved aluminum by ICP-OES in drinking water samples from wells and spring source located at Billings dam region. Before irradiation, the spring source and wells' samples showed aluminum levels of 0.020 mg/l and 0.2 mg/l respectively; after irradiation, both samples showed a 8-fold increase of aluminum concentration. These results are discussed considering other physical and chemical parameters and peculiarities of sample sources. (author)

  17. Advances in Radiocarbon Measurement of Water Samples

    Energy Technology Data Exchange (ETDEWEB)

    Janovics, R.; Molnar, M.; Major, I. [Institute of Nuclear Research (ATO MKI), Hungarian Academy of Sciences, H-4001 Debrecen (Hungary); Svetlik, I. [Department of Radiation Dosimetry, Nuclear Physics Institute AS CR, Prague (Czech Republic); Wacker, L. [Institute for Particle Physics, ETH Hoenggerberg, Zuerich (Switzerland)

    2013-07-15

    In this paper two very different and novel methods for the {sup 14}C measurement of water samples are presented. The first method uses direct absorption into a scintillation cocktail and a following liquid scintillation measurement. Typical sample size is 20-40 L and overall uncertainty is {+-} 2% for modern samples. It is a very cost effective and easy to use method based on a novel and simple static absorption process for the CO{sub 2} extracted from groundwater. The other very sensitive method is based on accelerator mass spectrometry (AMS) using a gas ion source. With a MICADAS type AMS system we demonstrated that you can routinely measure the {sup 14}C content of 1 mL of water sample with better than 1% precision (for a modern sample). This direct {sup 14}C AMS measurement of water takes less than 20 minutes including sample preparation. (author)

  18. Design of a micro-irrigation system based on the control volume method

    Directory of Open Access Journals (Sweden)

    Chasseriaux G.

    2006-01-01

    Full Text Available A micro-irrigation system design based on control volume method using the back step procedure is presented in this study. The proposed numerical method is simple and consists of delimiting an elementary volume of the lateral equipped with an emitter, called « control volume » on which the conservation equations of the fl uid hydrodynamicʼs are applied. Control volume method is an iterative method to calculate velocity and pressure step by step throughout the micro-irrigation network based on an assumed pressure at the end of the line. A simple microcomputer program was used for the calculation and the convergence was very fast. When the average water requirement of plants was estimated, it is easy to choose the sum of the average emitter discharge as the total average fl ow rate of the network. The design consists of exploring an economical and effi cient network to deliver uniformly the input fl ow rate for all emitters. This program permitted the design of a large complex network of thousands of emitters very quickly. Three subroutine programs calculate velocity and pressure at a lateral pipe and submain pipe. The control volume method has already been tested for lateral design, the results from which were validated by other methods as fi nite element method, so it permits to determine the optimal design for such micro-irrigation network

  19. Micro-Structure Measurement and Imaging Based on Digital Holography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kyeong Suk; Jung, Hyun Chul; Chang, Ho Seob; Akhter, Naseem [Chosun University, Gwangju (Korea, Republic of); Kee, Chang Doo [Chonnam National University, Gwangju (Korea, Republic of)

    2010-06-15

    Advancements in the imaging and computing technology have opened the path to digital holography for non-destructive investigations of technical samples, material property measurement, vibration analysis, flow visualization and stress analysis in aerospace industry which has widened the application of digital holography in the above fields. In this paper, we demonstrate the non-destructive investigation and micro-structure measurement application of digital holography to the small particles and a biological sample. This paper gives a brief description of the digital holograms recorded with this system and illustratively demonstrated

  20. Micro-Structure Measurement and Imaging Based on Digital Holography

    International Nuclear Information System (INIS)

    Kim, Kyeong Suk; Jung, Hyun Chul; Chang, Ho Seob; Akhter, Naseem; Kee, Chang Doo

    2010-01-01

    Advancements in the imaging and computing technology have opened the path to digital holography for non-destructive investigations of technical samples, material property measurement, vibration analysis, flow visualization and stress analysis in aerospace industry which has widened the application of digital holography in the above fields. In this paper, we demonstrate the non-destructive investigation and micro-structure measurement application of digital holography to the small particles and a biological sample. This paper gives a brief description of the digital holograms recorded with this system and illustratively demonstrated

  1. Sampling methods

    International Nuclear Information System (INIS)

    Loughran, R.J.; Wallbrink, P.J.; Walling, D.E.; Appleby, P.G.

    2002-01-01

    Methods for the collection of soil samples to determine levels of 137 Cs and other fallout radionuclides, such as excess 210 Pb and 7 Be, will depend on the purposes (aims) of the project, site and soil characteristics, analytical capacity, the total number of samples that can be analysed and the sample mass required. The latter two will depend partly on detector type and capabilities. A variety of field methods have been developed for different field conditions and circumstances over the past twenty years, many of them inherited or adapted from soil science and sedimentology. The use of them inherited or adapted from soil science and sedimentology. The use of 137 Cs in erosion studies has been widely developed, while the application of fallout 210 Pb and 7 Be is still developing. Although it is possible to measure these nuclides simultaneously, it is common for experiments to designed around the use of 137 Cs along. Caesium studies typically involve comparison of the inventories found at eroded or sedimentation sites with that of a 'reference' site. An accurate characterization of the depth distribution of these fallout nuclides is often required in order to apply and/or calibrate the conversion models. However, depending on the tracer involved, the depth distribution, and thus the sampling resolution required to define it, differs. For example, a depth resolution of 1 cm is often adequate when using 137 Cs. However, fallout 210 Pb and 7 Be commonly has very strong surface maxima that decrease exponentially with depth, and fine depth increments are required at or close to the soil surface. Consequently, different depth incremental sampling methods are required when using different fallout radionuclides. Geomorphic investigations also frequently require determination of the depth-distribution of fallout nuclides on slopes and depositional sites as well as their total inventories

  2. Reliability of a Cryoscopic Micro-Osmometer Using 15-µL Plasma Samples to Measure Hydration Status in Varied Environmental Conditions

    Science.gov (United States)

    Scanlan, Aaron T.; Richter-Stretton, Gina L.; Madueno, Maria C.; Borges, Nattai R.; Fenning, Andrew S.

    2017-01-01

    Measurement of plasma osmolality (P[subscript osm]) remains popular for assessing hydration status in exercise science. However, a controlled reliability assessment of micro-osmometry using small sample volumes to measure Posm remains to be performed. This study aimed to examine the reliability of a cryoscopic micro-osmometer requiring 15-µL…

  3. Experimental and numerical examination of eddy (Foucault) currents in rotating micro-coils: Generation of heat and its impact on sample temperature

    Science.gov (United States)

    Aguiar, Pedro M.; Jacquinot, Jacques-François; Sakellariou, Dimitris

    2009-09-01

    The application of nuclear magnetic resonance (NMR) to systems of limited quantity has stimulated the use of micro-coils (diameter Foucault (eddy) currents, which generate heat. We report the first data acquired with a 4 mm MACS system and spinning up to 10 kHz. The need to spin faster necessitates improved methods to control heating. We propose an approximate solution to calculate the power losses (heat) from the eddy currents for a solenoidal coil, in order to provide insight into the functional dependencies of Foucault currents. Experimental tests of the dependencies reveal conditions which result in reduced sample heating and negligible temperature distributions over the sample volume.

  4. Experimental and numerical examination of eddy (Foucault) currents in rotating micro-coils: Generation of heat and its impact on sample temperature.

    Science.gov (United States)

    Aguiar, Pedro M; Jacquinot, Jacques-François; Sakellariou, Dimitris

    2009-09-01

    The application of nuclear magnetic resonance (NMR) to systems of limited quantity has stimulated the use of micro-coils (diameter Foucault (eddy) currents, which generate heat. We report the first data acquired with a 4mm MACS system and spinning up to 10kHz. The need to spin faster necessitates improved methods to control heating. We propose an approximate solution to calculate the power losses (heat) from the eddy currents for a solenoidal coil, in order to provide insight into the functional dependencies of Foucault currents. Experimental tests of the dependencies reveal conditions which result in reduced sample heating and negligible temperature distributions over the sample volume.

  5. Plasma-nitriding assisted micro-texturing into stainless steel molds

    Directory of Open Access Journals (Sweden)

    Aizawa Tatsuhiko

    2015-01-01

    Full Text Available Micro-texturing has grown up to be one of the most promising procedures. This related application required for large-area, fine micro-texturing onto the stainless steel mold materials. A new method other than laser-machining, micro-milling or micro-EDM was awaited for further advancement of this micro-texturing. In the present paper, a plasma nitriding assisted micro-texturing was developed to make various kinds of micro-patterns onto the martensitic stainless steels. First, original patterns were printed onto the surface of substrate by using the ink-jet printer. Then, the masked substrate was subjected to high density plasma nitriding; the un-masked surfaces were nitrided to have higher hardness. This nitrided substrate was further treated by sand-blasting to selectively dig the soft, masked surfaces. Finally, the micro-patterned martensitic stainless steel substrate was fabricated as a mold to duplicate these micro-patterns onto the work materials. The spatial resolution and depth profile controllability of this plasma nitriding assisted micro-texturing was investigated for variety of initial micro-patterns. The original size and dimension of initial micro-patterns were precisely compared with the three dimensional geometry of micro-textures after blasting treatment. The plastic cover case for smart cellular phones was employed to demonstrate how useful this processing is in practice.

  6. Centrifugation: an important pre-analytic procedure that influences plasma microRNA quantification during blood processing.

    Science.gov (United States)

    Zheng, Xiao-Hui; Cui, Cui; Zhou, Xin-Xi; Zeng, Yi-Xin; Jia, Wei-Hua

    2013-12-01

    Circulating microRNAs are robustly present in plasma or serum and have become a research focus as biomarkers for tumor diagnosis and prognosis. Centrifugation is a necessary procedure for obtaining high-quality blood supernatant. Herein, we investigated one-step and two-step centrifugations, two centrifugal methods routinely used in microRNA study, to explore their effects on plasma microRNA quantification. The microRNAs obtained from one-step and two-step centrifugations were quantified by microarray and TaqMan-based real-time quantitative polymerase chain reaction (Q-PCR). Dynamic light scattering was performed to explore the difference underlying the two centrifugal methods. The results from the microarray containing 1,347 microRNAs showed that the signal detection rate was greatly decreased in the plasma sample prepared by two-step centrifugation. More importantly, the microRNAs missing in this plasma sample could be recovered and detected in the precipitate generated from the second centrifugation. Consistent with the results from microarray, a marked decrease of three representative microRNAs in two-step centrifugal plasma was validated by Q-PCR. According to the size distribution of all nanoparticles in plasma, there were fewer nanoparticles with size >1,000 nm in two-step centrifugal plasma. Our experiments directly demonstrated that different centrifugation methods produced distinct quantities of plasma microRNAs. Thus, exosomes or protein complexes containing microRNAs may be involved in large nanoparticle formation and may be precipitated after two-step centrifugation. Our results remind us that sample processing methods should be first considered in conducting research.

  7. Review of Micro/Nanotechnologies for Microbial Biosensors

    Directory of Open Access Journals (Sweden)

    Ji Won eLim

    2015-05-01

    Full Text Available A microbial biosensor is an analytical device with a biologically integrated transducer that generates a measurable signal indicating the analyte concentration. This method is ideally suited for the analysis of extracellular chemicals and the environment, and for metabolic sensory-regulation. Although microbial biosensors show promise for application in various detection fields, some limitations still remain such as poor selectivity, low sensitivity, and impractical portability. To overcome such limitations, microbial biosensors have been integrated with many recently developed micro/nanotechnologies and applied to a wide range of detection purposes. This review article discusses micro/nanotechnologies that have been integrated with microbial biosensors and summarizes recent advances and the applications achieved through such novel integration. Future perspectives on the combination of micro/nanotechnologies and microbial biosensors will be discussed, and the necessary developments and improvements will be strategically deliberated.

  8. Evaluation of polymer micro parts produced by additive manufacturing processes using vat photopolymerization method

    DEFF Research Database (Denmark)

    Davoudinejad, Ali; Pedersen, David Bue; Tosello, Guido

    2017-01-01

    Micro manufacturing scale feature production by Additive Manufacturing (AM) processes for the direct production of miniaturized polymer components is analysed in this work. The study characterizes the AM processes for polymer micro parts productions using the vat photopolymerization method...

  9. Simple method based on intensity measurements for characterization of aberrations from micro-optical components.

    Science.gov (United States)

    Perrin, Stephane; Baranski, Maciej; Froehly, Luc; Albero, Jorge; Passilly, Nicolas; Gorecki, Christophe

    2015-11-01

    We report a simple method, based on intensity measurements, for the characterization of the wavefront and aberrations produced by micro-optical focusing elements. This method employs the setup presented earlier in [Opt. Express 22, 13202 (2014)] for measurements of the 3D point spread function, on which a basic phase-retrieval algorithm is applied. This combination allows for retrieval of the wavefront generated by the micro-optical element and, in addition, quantification of the optical aberrations through the wavefront decomposition with Zernike polynomials. The optical setup requires only an in-motion imaging system. The technique, adapted for the optimization of micro-optical component fabrication, is demonstrated by characterizing a planoconvex microlens.

  10. Detection of plant microRNAs in honey.

    Directory of Open Access Journals (Sweden)

    Angelo Gismondi

    Full Text Available For the first time in the literature, our group has managed to demonstrate the existence of plant RNAs in honey samples. In particular, in our work, different RNA extraction procedures were performed in order to identify a purification method for nucleic acids from honey. Purity, stability and integrity of the RNA samples were evaluated by spectrophotometric, PCR and electrophoretic analyses. Among all honey RNAs, we specifically revealed the presence of both plastidial and nuclear plant transcripts: RuBisCO large subunit mRNA, maturase K messenger and 18S ribosomal RNA. Surprisingly, nine plant microRNAs (miR482b, miR156a, miR396c, miR171a, miR858, miR162a, miR159c, miR395a and miR2118a were also detected and quantified by qPCR. In this context, a comparison between microRNA content in plant samples (i.e. flowers, nectars and their derivative honeys was carried out. In addition, peculiar microRNA profiles were also identified in six different monofloral honeys. Finally, the same plant microRNAs were investigated in other plant food products: tea, cocoa and coffee. Since plant microRNAs introduced by diet have been recently recognized as being able to modulate the consumer's gene expression, our research suggests that honey's benefits for human health may be strongly correlated to the bioactivity of plant microRNAs contained in this matrix.

  11. Development and preliminary experimental study on micro-stacked insulator

    International Nuclear Information System (INIS)

    Ren Chengyan; Yuan Weiqun; Zhang Dongdong; Yan Ping; Wang Jue

    2009-01-01

    High gradient insulating technology is one of the key technologies in new type dielectric wall accelerator(DWA). High gradient insulator, namely micro-stacked insulator, was developed and preliminary experimental study was done. Based on the finite element and particle simulating method, surface electric field distribution and electron movement track of micro-stacked insulator were numerated, and then the optimized design proposal was put forward. Using high temperature laminated method, we developed micro-stacked insulator samples which uses exhaustive fluorinated ethylene propylene(FEP) as dielectric layer and stainless steel as metal layer. Preliminary experiment of vacuum surface flashover in nanosecond pulse voltage was done and micro-stacked insulator exhibited favorable vacuum surface flashover performance with flashover field strength of near 180 kV/cm. (authors)

  12. Micro Machining of Injection Mold Inserts for Fluidic Channel of Polymeric Biochips

    Directory of Open Access Journals (Sweden)

    Myeong-Woo Cho

    2007-08-01

    Full Text Available Recently, the polymeric micro-fluidic biochip, often called LOC (lab-on-a-chip, has been focused as a cheap, rapid and simplified method to replace the existing biochemical laboratory works. It becomes possible to form miniaturized lab functionalities on a chip with the development of MEMS technologies. The micro-fluidic chips contain many micro-channels for the flow of sample and reagents, mixing, and detection tasks. Typical substrate materials for the chip are glass and polymers. Typical techniques for micro-fluidic chip fabrication are utilizing various micro pattern forming methods, such as wet-etching, micro-contact printing, and hot-embossing, micro injection molding, LIGA, and micro powder blasting processes, etc. In this study, to establish the basis of the micro pattern fabrication and mass production of polymeric micro-fluidic chips using injection molding process, micro machining method was applied to form micro-channels on the LOC molds. In the research, a series of machining experiments using micro end-mills were performed to determine optimum machining conditions to improve surface roughness and shape accuracy of designed simplified micro-channels. Obtained conditions were used to machine required mold inserts for micro-channels using micro end-mills. Test injection processes using machined molds and COC polymer were performed, and then the results were investigated.

  13. Comparisons of methods for generating conditional Poisson samples and Sampford samples

    OpenAIRE

    Grafström, Anton

    2005-01-01

    Methods for conditional Poisson sampling (CP-sampling) and Sampford sampling are compared and the focus is on the efficiency of the methods. The efficiency is investigated by simulation in different sampling situations. It was of interest to compare methods since new methods for both CP-sampling and Sampford sampling were introduced by Bondesson, Traat & Lundqvist in 2004. The new methods are acceptance rejection methods that use the efficient Pareto sampling method. They are found to be ...

  14. Micro-/nanostructured multicomponent molecular materials: design, assembly, and functionality.

    Science.gov (United States)

    Yan, Dongpeng

    2015-03-23

    Molecule-based micro-/nanomaterials have attracted considerable attention because their properties can vary greatly from the corresponding macro-sized bulk systems. Recently, the construction of multicomponent molecular solids based on crystal engineering principles has emerged as a promising alternative way to develop micro-/nanomaterials. Unlike single-component materials, the resulting multicomponent systems offer the advantages of tunable composition, and adjustable molecular arrangement, and intermolecular interactions within their solid states. The study of these materials also supplies insight into how the crystal structure, molecular components, and micro-/nanoscale effects can influence the performance of molecular materials. In this review, we describe recent advances and current directions in the assembly and applications of crystalline multicomponent micro-/nanostructures. Firstly, the design strategies for multicomponent systems based on molecular recognition and crystal engineering principles are introduced. Attention is then focused on the methods of fabrication of low-dimensional multicomponent micro-/nanostructures. Their new applications are also outlined. Finally, we briefly discuss perspectives for the further development of these molecular crystalline micro-/nanomaterials. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Active Search on Carcasses versus Pitfall Traps: a Comparison of Sampling Methods.

    Science.gov (United States)

    Zanetti, N I; Camina, R; Visciarelli, E C; Centeno, N D

    2016-04-01

    The study of insect succession in cadavers and the classification of arthropods have mostly been done by placing a carcass in a cage, protected from vertebrate scavengers, which is then visited periodically. An alternative is to use specific traps. Few studies on carrion ecology and forensic entomology involving the carcasses of large vertebrates have employed pitfall traps. The aims of this study were to compare both sampling methods (active search on a carcass and pitfall trapping) for each coleopteran family, and to establish whether there is a discrepancy (underestimation and/or overestimation) in the presence of each family by either method. A great discrepancy was found for almost all families with some of them being more abundant in samples obtained through active search on carcasses and others in samples from traps, whereas two families did not show any bias towards a given sampling method. The fact that families may be underestimated or overestimated by the type of sampling technique highlights the importance of combining both methods, active search on carcasses and pitfall traps, in order to obtain more complete information on decomposition, carrion habitat and cadaveric families or species. Furthermore, a hypothesis advanced on the reasons for the underestimation by either sampling method showing biases towards certain families. Information about the sampling techniques indicating which would be more appropriate to detect or find a particular family is provided.

  16. Silicon micro-masonry using elastomeric stamps for three-dimensional microfabrication

    International Nuclear Information System (INIS)

    Keum, Hohyun; Eisenhaure, Jeffrey D; Kim, Seok; Carlson, Andrew; Ning, Hailong; Mihi, Agustin; Braun, Paul V; Rogers, John A

    2012-01-01

    We present a micromanufacturing method for constructing microsystems, which we term ‘micro-masonry’ based on individual manipulation, influenced by strategies for deterministic materials assembly using advanced forms of transfer printing. Analogous to masonry in construction sites, micro-masonry consists of the preparation, manipulation, and binding of microscale units to assemble microcomponents and microsystems. In this paper, for the purpose of demonstration, we used microtipped elastomeric stamps as manipulators and built three dimensional silicon microstructures. Silicon units of varied shapes were fabricated in a suspended format on donors, retrieved, delivered, and placed on a target location on a receiver using microtipped stamps. Annealing of the assembled silicon units permanently bound them and completed the micro-masonry procedure. (paper)

  17. Comparison of Different Numerical Methods for Quality Factor Calculation of Nano and Micro Photonic Cavities

    DEFF Research Database (Denmark)

    Taghizadeh, Alireza; Mørk, Jesper; Chung, Il-Sug

    2014-01-01

    Four different numerical methods for calculating the quality factor and resonance wavelength of a nano or micro photonic cavity are compared. Good agreement was found for a wide range of quality factors. Advantages and limitations of the different methods are discussed.......Four different numerical methods for calculating the quality factor and resonance wavelength of a nano or micro photonic cavity are compared. Good agreement was found for a wide range of quality factors. Advantages and limitations of the different methods are discussed....

  18. Direct immersion single drop micro-extraction method for multi-class pesticides analysis in mango using GC-MS.

    Science.gov (United States)

    Pano-Farias, Norma S; Ceballos-Magaña, Silvia G; Muñiz-Valencia, Roberto; Jurado, Jose M; Alcázar, Ángela; Aguayo-Villarreal, Ismael A

    2017-12-15

    Due the negative effects of pesticides on environment and human health, more efficient and environmentally friendly methods are needed. In this sense, a simple, fast, free from memory effects and economical direct-immersion single drop micro-extraction (SDME) method and GC-MS for multi-class pesticides determination in mango samples was developed. Sample pre-treatment using ultrasound-assisted solvent extraction and factors affecting the SDME procedure (extractant solvent, drop volume, stirring rate, ionic strength, time, pH and temperature) were optimized using factorial experimental design. This method presented high sensitive (LOD: 0.14-169.20μgkg -1 ), acceptable precision (RSD: 0.7-19.1%), satisfactory recovery (69-119%) and high enrichment factors (20-722). Several obtained LOQs are below the MRLs established by the European Commission; therefore, the method could be applied for pesticides determination in routing analysis and custom laboratories. Moreover, this method has shown to be suitable for determination of some of the studied pesticides in lime, melon, papaya, banana, tomato, and lettuce. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Advanced Electron Microscopy and Micro analytical technique development and application for Irradiated TRISO Coated Particles from the AGR-1 Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Van Rooyen, Isabella Johanna [Idaho National Lab. (INL), Idaho Falls, ID (United States); Lillo, Thomas Martin [Idaho National Lab. (INL), Idaho Falls, ID (United States); Wen, Haiming [Idaho National Lab. (INL), Idaho Falls, ID (United States); Wright, Karen Elizabeth [Idaho National Lab. (INL), Idaho Falls, ID (United States); Madden, James Wayne [Idaho National Lab. (INL), Idaho Falls, ID (United States); Aguiar, Jeffery Andrew [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2017-01-01

    A series of up to seven irradiation experiments are planned for the Advanced Gas Reactor (AGR) Fuel Development and Quantification Program, with irradiation completed at the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL) for the first experiment (i.e., AGR-1) in November 2009 for an effective 620 full power days. The objective of the AGR-1 experiment was primarily to provide lessons learned on the multi-capsule test train design and to provide early data on fuel performance for use in fuel fabrication process development and post-irradiation safety testing data at high temperatures. This report describes the advanced microscopy and micro-analysis results on selected AGR-1 coated particles.

  20. Q Sepharose micro-column chromatography: A simple screening method for identifying beta thalassemia traits and hemoglobin E carriers.

    Science.gov (United States)

    Wong, Peerapon; Sritippayawan, Suchila; Suwannakhon, Narutchala; Tapprom, Akamon; Deoisares, Rawisut; Sanguansermsri, Torpong

    2016-11-01

    For beta thalassemia control program in pregnancy, mass screening of the carrier state by determination of the hemoglobin (Hb) A 2 and Hb E proportions and mutation analysis is a preferred method for making prenatal diagnoses. Q Sepharose micro-column chromatography, developed for the determination of Hb A 2 and Hb E for screening purposes, was compared with high performance liquid chromatography (HPLC) to ascertain its relative accuracy and reliability. Results using Q Sepharose micro-column chromatography in 350 blood specimens, including 50 samples genetically proven to be beta thalassemia heterozygotes, were compared to HPLC for validation. An additional study was conducted to test a clinical application on a large-scale survey for beta thalassemia in 1581 pregnant women and their spouses. The mean (±SD) Hb A 2 proportions in the normal and genetically proven beta thalassemia heterozygotes were 2.70±0.40% and 6.30±1.23%, respectively, as determined by Q-Sepharose micro-column chromatography, and 2.65±0.31% and 5.37±0.96%, respectively, as determined by HPLC. The mean Hb E proportions in the Hb E heterozygotes were 23.25±4.13% and 24.72±3.5% as determined by Q Sepharose micro-column chromatography and HPLC, respectively. In the large-scale survey for beta thalassemia, 23 at risk couples were detected. Seven affected fetuses were identified by prenatal diagnosis. Q Sepharose micro-column chromatography was found to be reliable, reproducible and well-suited for large-scale surveys. Additionally, by being reusable and convenient, this simple and economical chromatography method may be an alternative means to screen for beta thalassemia and Hb E carriers in the mass population. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  1. A biodetection method using magnetic particles and micro traps

    KAUST Repository

    Li, Fuquan

    2012-03-09

    The general working principle of magnetoresistive sensors for biological applications is to specifically attach bioanalytesto magnetic particles and then detect the particles that are immobilized on the sensor surface. The immobilization of the particles on the sensor surface commonly uses biomolecular interactions, e.g., antigen-antibody. Thus, the sensor surface needs to be functionalized via biological treatments in order to capture certain bioanalytes. In the presented work, a new method is proposed, which does not rely on functionalization of the sensor surface. Current carrying microstructures in combination with mechanical micro traps are used to immobilize magnetic particles. Analyte detection is based on the difference in size between bare magnetic particles and particles with analyte attached, which causes a different number of particles to be captured in the micro traps.

  2. Nondestructive Analysis of Astromaterials by Micro-CT and Micro-XRF Analysis for PET Examination

    Science.gov (United States)

    Zeigler, R. A.; Righter, K.; Allen, C. C.

    2013-01-01

    An integral part of any sample return mission is the initial description and classification of returned samples by the preliminary examination team (PET). The goal of the PET is to characterize and classify returned samples and make this information available to the larger research community who then conduct more in-depth studies on the samples. The PET tries to minimize the impact their work has on the sample suite, which has in the past limited the PET work to largely visual, nonquantitative measurements (e.g., optical microscopy). More modern techniques can also be utilized by a PET to nondestructively characterize astromaterials in much more rigorous way. Here we discuss our recent investigations into the applications of micro-CT and micro-XRF analyses with Apollo samples and ANSMET meteorites and assess the usefulness of these techniques in future PET. Results: The application of micro computerized tomography (micro-CT) to astromaterials is not a new concept. The technique involves scanning samples with high-energy x-rays and constructing 3-dimensional images of the density of materials within the sample. The technique can routinely measure large samples (up to approx. 2700 cu cm) with a small individual voxel size (approx. 30 cu m), and has the sensitivity to distinguish the major rock forming minerals and identify clast populations within brecciated samples. We have recently run a test sample of a terrestrial breccia with a carbonate matrix and multiple igneous clast lithologies. The test results are promising and we will soon analyze a approx. 600 g piece of Apollo sample 14321 to map out the clast population within the sample. Benchtop micro x-ray fluorescence (micro-XRF) instruments can rapidly scan large areas (approx. 100 sq cm) with a small pixel size (approx. 25 microns) and measure the (semi) quantitative composition of largely unprepared surfaces for all elements between Be and U, often with sensitivity on the order of a approx. 100 ppm. Our recent

  3. Applying a foil queue micro-electrode in micro-EDM to fabricate a 3D micro-structure

    Science.gov (United States)

    Xu, Bin; Guo, Kang; Wu, Xiao-yu; Lei, Jian-guo; Liang, Xiong; Guo, Deng-ji; Ma, Jiang; Cheng, Rong

    2018-05-01

    Applying a 3D micro-electrode in a micro electrical discharge machining (micro-EDM) can fabricate a 3D micro-structure with an up and down reciprocating method. However, this processing method has some shortcomings, such as a low success rate and a complex process for fabrication of 3D micro-electrodes. By focusing on these shortcomings, this paper proposed a novel 3D micro-EDM process based on the foil queue micro-electrode. Firstly, a 3D micro-electrode was discretized into several foil micro-electrodes and these foil micro-electrodes constituted a foil queue micro-electrode. Then, based on the planned process path, foil micro-electrodes were applied in micro-EDM sequentially and the micro-EDM results of each foil micro-electrode were able to superimpose the 3D micro-structure. However, the step effect will occur on the 3D micro-structure surface, which has an adverse effect on the 3D micro-structure. To tackle this problem, this paper proposes to reduce this adverse effect by rounded corner wear at the end of the foil micro-electrode and studies the impact of machining parameters on rounded corner wear and the step effect on the micro-structure surface. Finally, using a wire cutting voltage of 80 V, a current of 0.5 A and a pulse width modulation ratio of 1:4, the foil queue micro-electrode was fabricated by wire electrical discharge machining. Also, using a pulse width of 100 ns, a pulse interval of 200 ns, a voltage of 100 V and workpiece material of 304# stainless steel, the foil queue micro-electrode was applied in micro-EDM for processing of a 3D micro-structure with hemispherical features, which verified the feasibility of this process.

  4. Advancements on the simulation of the micro injection moulding process

    DEFF Research Database (Denmark)

    Marhöfer, David Maximilian; Tosello, Guido; Hansen, Hans Nørgaard

    2013-01-01

    injection molding, because they are developed for macro plastic parts and they are therefore limited in the capability of modeling the polymer flow in micro cavities properly. However, new opportunities for improved accuracy have opened up due to current developments of the simulation technology. Hence, new......Process simulations are applied in micro injection molding with the same purpose as in conventional injection molding: aiming at optimization and support of the design of mold, inserts, plastic products, and the process itself. Available software packages are however not well suited for micro...

  5. Micro-PIXE in plant sciences

    International Nuclear Information System (INIS)

    Mesjasz-Przybylowicz, J.; Przybylowicz, W.J.

    2013-01-01

    Full text: Studies of the role played by elements in fundamental processes in physiology, nutrition, elemental deficiency and toxicity as well as environmental pollution require accurate, quantitative methods with good spatial resolution. the problem of proper measurements of elemental balances and elemental transfers between various levels of biological organisation (from abiotic to biotic systems; along the food chains; within organs and cells) becomes essential for understanding the mechanisms influencing the selection, interaction, distribution and transport of elements. Highly sensitive techniques for bulk elemental analysis are mostly used in these investigations. These techniques usually offer adequate sensitivity, but without spatial resolution. On the other hand, advanced studies of elemental distribution at a cellular level are mostly conducted using techniques with high spatial resolution, but low sensitivity. Ideally, these studies should be conducted on organs and tissues of sizes as far down as the cellular and sub-cellular level. This applies to e.g. future directions in ionomics and metallomics and opens up new, exciting possibilities of studies of trace metal role. The micro-PIXE has been applied in plant sciences for more than thirty years and has reached a high level of maturity. This is one of the few microanalytical, multielemental techniques capable of quantitative studies of elemental distribution at ppm level with with ability to perform quantitative elemental mapping and easy quantification of data extracted from selected micro-areas. Preparation of biological specimens is undoubtedly the crucial and most difficult part of analysis, and only cryotechniques are recommended presently for ali types of microanalytical studies. Established sample preparation protocols will be presented. Most of results are obtained for cryofixed and freeze-dried material but analysis of samples in frozen-hydrated state brings important advantage. Recent

  6. Comparison of Three Sample Preparation Methods for Analysis of Chemical Warfare Agent Stimulants in Water

    International Nuclear Information System (INIS)

    Alessandro Sassolini

    2015-01-01

    Analytical chemistry in CBRNe (Chemical Biological Radiological Nuclear explosive) context requires not only high quality data; quickness, ruggedness and robustness are also mandatory. In this work, three samples preparation methods were compared using several organophosphorus pesticides as test compounds, used as stimulants of nerve CWA (Chemical Warfare Agents) to choose the one with best characteristics. Result was obtained better with the Dispersive Liquid-Liquid Micro Extraction (DLLME), relatively new in CBRNe field, obtaining uncertainty for different simulants between 8 and 15 % while a quantification limit between 0.01 and 0.08 μg/ l. To optimize this extraction method, different organo chlorinated solvents also tested but not relevant difference in these tests was obtained. In this work, all samples were analyzed by using a gas chromatography coupled with mass spectrometer (GC-MS) and also with Gas Chromatograph coupled with Nitrogen Phosphorous Detector (NPD) for DLLME samples to evaluate a low cost and rugged instrument adapt to field analytical methods with good performance in terms of uncertainty and sensibility even if poorer respect to the mass spectrometry. (author)

  7. Vibrational Micro-Spectroscopy of Human Tissues Analysis: Review.

    Science.gov (United States)

    Bunaciu, Andrei A; Hoang, Vu Dang; Aboul-Enein, Hassan Y

    2017-05-04

    Vibrational spectroscopy (Infrared (IR) and Raman) and, in particular, micro-spectroscopy and micro-spectroscopic imaging have been used to characterize developmental changes in tissues, to monitor these changes in cell cultures and to detect disease and drug-induced modifications. The conventional methods for biochemical and histophatological tissue characterization necessitate complex and "time-consuming" sample manipulations and the results are rarely quantifiable. The spectroscopy of molecular vibrations using mid-IR or Raman techniques has been applied to samples of human tissue. This article reviews the application of these vibrational spectroscopic techniques for analysis of biological tissue published between 2005 and 2015.

  8. Identification of Reliable Reference Genes for Quantification of MicroRNAs in Serum Samples of Sulfur Mustard-Exposed Veterans.

    Science.gov (United States)

    Gharbi, Sedigheh; Shamsara, Mehdi; Khateri, Shahriar; Soroush, Mohammad Reza; Ghorbanmehr, Nassim; Tavallaei, Mahmood; Nourani, Mohammad Reza; Mowla, Seyed Javad

    2015-01-01

    In spite of accumulating information about pathological aspects of sulfur mustard (SM), the precise mechanism responsible for its effects is not well understood. Circulating microRNAs (miRNAs) are promising biomarkers for disease diagnosis and prognosis. Accurate normalization using appropriate reference genes, is a critical step in miRNA expression studies. In this study, we aimed to identify appropriate reference gene for microRNA quantification in serum samples of SM victims. In this case and control experimental study, using quantitative real-time polymerase chain reaction (qRT-PCR), we evaluated the suitability of a panel of small RNAs including SNORD38B, SNORD49A, U6, 5S rRNA, miR-423-3p, miR-191, miR-16 and miR-103 in sera of 28 SM-exposed veterans of Iran-Iraq war (1980-1988) and 15 matched control volunteers. Different statistical algorithms including geNorm, Normfinder, best-keeper and comparative delta-quantification cycle (Cq) method were employed to find the least variable reference gene. miR-423-3p was identified as the most stably expressed reference gene, and miR- 103 and miR-16 ranked after that. We demonstrate that non-miRNA reference genes have the least stabil- ity in serum samples and that some house-keeping miRNAs may be used as more reliable reference genes for miRNAs in serum. In addition, using the geometric mean of two reference genes could increase the reliability of the normalizers.

  9. Micro and Nanotechnologies Enhanced Biomolecular Sensing

    Directory of Open Access Journals (Sweden)

    Tza-Huei Wang

    2013-07-01

    Full Text Available This editorial summarizes some of the recent advances of micro and nanotechnology-based tools and devices for biomolecular detection. These include the incorporation of nanomaterials into a sensor surface or directly interfacing with molecular probes to enhance target detection via more rapid and sensitive responses, and the use of self-assembled organic/inorganic nanocomposites that inhibit exceptional spectroscopic properties to enable facile homogenous assays with efficient binding kinetics. Discussions also include some insight into microfluidic principles behind the development of an integrated sample preparation and biosensor platform toward a miniaturized and fully functional system for point of care applications.

  10. Micro-fluidic module for blood cell separation for gene expression radiobiological assays

    International Nuclear Information System (INIS)

    Brengues, Muriel; Gu, Jian; Zenhausern, Frederic

    2015-01-01

    Advances in molecular techniques have improved discovery of biomarkers associated with radiation exposure. Gene expression techniques have been demonstrated as effective tools for biodosimetry, and different assay platforms with different chemistries are now available. One of the main challenges is to integrate the sample preparation processing of these assays into micro-fluidic platforms to be fully automated for point-of-care medical countermeasures in the case of a radiological event. Most of these assays follow the same workflow processing that comprises first the collection of blood samples followed by cellular and molecular sample preparation. The sample preparation is based on the specific reagents of the assay system and depends also on the different subsets of cells population and the type of biomarkers of interest. In this article, the authors present a module for isolation of white blood cells from peripheral blood as a prerequisite for automation of gene expression assays on a micro-fluidic cartridge. For each sample condition, the gene expression platform can be adapted to suit the requirements of the selected assay chemistry (authors)

  11. Determination of Zinc Ions in Environmental Samples by Dispersive Liquid- Liquid Micro Extraction and Atomic Absorption Spectroscopy

    Directory of Open Access Journals (Sweden)

    F. Arabi

    2012-11-01

    Full Text Available In this work preconcentration of the Zn ions was investigated in water sample by Dispersive liquid- liquid micro extraction (DLLME using chloroform as an extraction solvent, methanol as a disperser solvent and 8-Hydroxyquinoline as a chelating agent. The determination of extracted ions was done by graphite furnace atomic absorption spectrometry. The influence of various analytical parameters including pH, extraction and disperser solvent type and volume and concentration of the chelating agent on the extraction efficiency of analyses was investigated. After extraction, the enrichment factor was 26 and the detection limit of the method was 0.0033 µg l-1 and the relative standard deviations (R.S.D for five determinations of 1 ng/ml Zn were 7.41%. 

  12. Micro-seismic Imaging Using a Source Independent Waveform Inversion Method

    KAUST Repository

    Wang, Hanchen

    2016-04-18

    Micro-seismology is attracting more and more attention in the exploration seismology community. The main goal in micro-seismic imaging is to find the source location and the ignition time in order to track the fracture expansion, which will help engineers monitor the reservoirs. Conventional imaging methods work fine in this field but there are many limitations such as manual picking, incorrect migration velocity and low signal to noise ratio (S/N). In traditional surface survey imaging, full waveform inversion (FWI) is widely used. The FWI method updates the velocity model by minimizing the misfit between the observed data and the predicted data. Using FWI to locate and image microseismic events allows for an automatic process (free of picking) that utilizes the full wavefield. Use the FWI technique, and overcomes the difficulties of manual pickings and incorrect velocity model for migration. However, the technique of waveform inversion of micro-seismic events faces its own problems. There is significant nonlinearity due to the unknown source location (space) and function (time). We have developed a source independent FWI of micro-seismic events to simultaneously invert for the source image, source function and velocity model. It is based on convolving reference traces with the observed and modeled data to mitigate the effect of an unknown source ignition time. The adjoint-state method is used to derive the gradient for the source image, source function and velocity updates. To examine the accuracy of the inverted source image and velocity model the extended image for source wavelet in z-axis is extracted. Also the angle gather is calculated to check the applicability of the migration velocity. By inverting for the source image, source wavelet and the velocity model simultaneously, the proposed method produces good estimates of the source location, ignition time and the background velocity in the synthetic experiments with both parts of the Marmousi and the SEG

  13. An Advanced Actuator Line Method for Wind Energy Applications and Beyond

    Energy Technology Data Exchange (ETDEWEB)

    Churchfield, Matthew J.; Schreck, Scott; Martinez-Tossas, Luis A.; Meneveau, Charles; Spalart, Philippe R.

    2017-01-09

    The actuator line method to represent rotor aerodynamics within computational fluid dynamics has been in use for over a decade. This method applies a body force to the flow field along rotating lines corresponding to the individual rotor blades and employs tabular airfoil data to compute the force distribution. The actuator line method is attractive because compared to blade-resolved simulations, the required mesh is much simpler and the computational cost is lower. This work proposes a higher fidelity variant of the actuator line method meant to fill the space between current actuator line and blade-resolved simulations. It contains modifications in two key areas. The first is that of freestream velocity vector estimation along the line, which is necessary to compute the lift and drag along the line using tabular airfoil data. Most current methods rely on point sampling in which the location of sampling is ambiguous. Here we test a velocity sampling method that uses a properly weighted integral over space, removing this ambiguity. The second area of improvement is the function used to project the one-dimensional actuator line force onto the three-dimensional fluid mesh as a body force. We propose and test a projection function that spreads the force over a region that looks something like a real blade with the hope that it will produce the blade local and near wake flow features with more accuracy and higher fidelity. Our goal is that between these two improvements, not only will the flow field predictions be enhanced, but also the spanwise loading will be made more accurate. We refer to this combination of improvements as the advanced actuator line method. We apply these improvements to two different wind turbine cases. Although there is a strong wind energy motivation in our work, there is no reason these advanced actuator line ideas cannot be used in other applications, such as helicopter rotors.

  14. Micro-Raman spectroscopy of natural and synthetic indigo samples.

    Science.gov (United States)

    Vandenabeele, Peter; Moens, Luc

    2003-02-01

    In this work indigo samples from three different sources are studied by using Raman spectroscopy: the synthetic pigment and pigments from the woad (Isatis tinctoria) and the indigo plant (Indigofera tinctoria). 21 samples were obtained from 8 suppliers; for each sample 5 Raman spectra were recorded and used for further chemometrical analysis. Principal components analysis (PCA) was performed as data reduction method before applying hierarchical cluster analysis. Linear discriminant analysis (LDA) was implemented as a non-hierarchical supervised pattern recognition method to build a classification model. In order to avoid broad-shaped interferences from the fluorescence background, the influence of 1st and 2nd derivatives on the classification was studied by using cross-validation. Although chemically identical, it is shown that Raman spectroscopy in combination with suitable chemometric methods has the potential to discriminate between synthetic and natural indigo samples.

  15. A Noise Reduction Method for Dual-Mass Micro-Electromechanical Gyroscopes Based on Sample Entropy Empirical Mode Decomposition and Time-Frequency Peak Filtering.

    Science.gov (United States)

    Shen, Chong; Li, Jie; Zhang, Xiaoming; Shi, Yunbo; Tang, Jun; Cao, Huiliang; Liu, Jun

    2016-05-31

    The different noise components in a dual-mass micro-electromechanical system (MEMS) gyroscope structure is analyzed in this paper, including mechanical-thermal noise (MTN), electronic-thermal noise (ETN), flicker noise (FN) and Coriolis signal in-phase noise (IPN). The structure equivalent electronic model is established, and an improved white Gaussian noise reduction method for dual-mass MEMS gyroscopes is proposed which is based on sample entropy empirical mode decomposition (SEEMD) and time-frequency peak filtering (TFPF). There is a contradiction in TFPS, i.e., selecting a short window length may lead to good preservation of signal amplitude but bad random noise reduction, whereas selecting a long window length may lead to serious attenuation of the signal amplitude but effective random noise reduction. In order to achieve a good tradeoff between valid signal amplitude preservation and random noise reduction, SEEMD is adopted to improve TFPF. Firstly, the original signal is decomposed into intrinsic mode functions (IMFs) by EMD, and the SE of each IMF is calculated in order to classify the numerous IMFs into three different components; then short window TFPF is employed for low frequency component of IMFs, and long window TFPF is employed for high frequency component of IMFs, and the noise component of IMFs is wiped off directly; at last the final signal is obtained after reconstruction. Rotation experimental and temperature experimental are carried out to verify the proposed SEEMD-TFPF algorithm, the verification and comparison results show that the de-noising performance of SEEMD-TFPF is better than that achievable with the traditional wavelet, Kalman filter and fixed window length TFPF methods.

  16. A Noise Reduction Method for Dual-Mass Micro-Electromechanical Gyroscopes Based on Sample Entropy Empirical Mode Decomposition and Time-Frequency Peak Filtering

    Directory of Open Access Journals (Sweden)

    Chong Shen

    2016-05-01

    Full Text Available The different noise components in a dual-mass micro-electromechanical system (MEMS gyroscope structure is analyzed in this paper, including mechanical-thermal noise (MTN, electronic-thermal noise (ETN, flicker noise (FN and Coriolis signal in-phase noise (IPN. The structure equivalent electronic model is established, and an improved white Gaussian noise reduction method for dual-mass MEMS gyroscopes is proposed which is based on sample entropy empirical mode decomposition (SEEMD and time-frequency peak filtering (TFPF. There is a contradiction in TFPS, i.e., selecting a short window length may lead to good preservation of signal amplitude but bad random noise reduction, whereas selecting a long window length may lead to serious attenuation of the signal amplitude but effective random noise reduction. In order to achieve a good tradeoff between valid signal amplitude preservation and random noise reduction, SEEMD is adopted to improve TFPF. Firstly, the original signal is decomposed into intrinsic mode functions (IMFs by EMD, and the SE of each IMF is calculated in order to classify the numerous IMFs into three different components; then short window TFPF is employed for low frequency component of IMFs, and long window TFPF is employed for high frequency component of IMFs, and the noise component of IMFs is wiped off directly; at last the final signal is obtained after reconstruction. Rotation experimental and temperature experimental are carried out to verify the proposed SEEMD-TFPF algorithm, the verification and comparison results show that the de-noising performance of SEEMD-TFPF is better than that achievable with the traditional wavelet, Kalman filter and fixed window length TFPF methods.

  17. A method of measuring micro-impulse with torsion pendulum based on multi-beam laser heterodyne

    Science.gov (United States)

    Li, Yan-Chao; Wang, Chun-Hui

    2012-02-01

    In this paper, we propose a novel method of multi-beam laser heterodyne measurement for micro-impulse. The measurement of the micro-impulse, which is converted into the measurement of the small tuning angle of the torsion pendulum, is realized by considering the interaction between pulse laser and working medium. Based on Doppler effect and heterodyne technology, the information regarding the small tuning angle is loaded to the frequency difference of the multi-beam laser heterodyne signal by the frequency modulation of the oscillating mirror, thereby obtaining many values of the small tuning angle after the multi-beam laser heterodyne signal demodulation simultaneously. Processing these values by weighted-average, the small tuning angle can be obtained accurately and the value of the micro-impulse can eventually be calculated. Using Polyvinylchlorid+2%C as a working medium, this novel method is used to simulate the value of the micro-impulse by MATLAB which is generated by considering the interaction between the pulse laser and the working medium, the obtained result shows that the relative error of this method is just 0.5%.

  18. A method of measuring micro-impulse with torsion pendulum based on multi-beam laser heterodyne

    International Nuclear Information System (INIS)

    Li Yan-Chao; Wang Chun-Hui

    2012-01-01

    In this paper, we propose a novel method of multi-beam laser heterodyne measurement for micro-impulse. The measurement of the micro-impulse, which is converted into the measurement of the small tuning angle of the torsion pendulum, is realized by considering the interaction between pulse laser and working medium. Based on Doppler effect and heterodyne technology, the information regarding the small tuning angle is loaded to the frequency difference of the multi-beam laser heterodyne signal by the frequency modulation of the oscillating mirror, thereby obtaining many values of the small tuning angle after the multi-beam laser heterodyne signal demodulation simultaneously. Processing these values by weighted-average, the small tuning angle can be obtained accurately and the value of the micro-impulse can eventually be calculated. Using Polyvinylchlorid+2%C as a working medium, this novel method is used to simulate the value of the micro-impulse by MATLAB which is generated by considering the interaction between the pulse laser and the working medium, the obtained result shows that the relative error of this method is just 0.5%. (general)

  19. 3D printing of nano- and micro-structures

    Science.gov (United States)

    Ramasamy, Mouli; Varadan, Vijay K.

    2016-04-01

    Additive manufacturing or 3D printing techniques are being vigorously investigated as a replacement to the traditional and conventional methods in fabrication to bring forth cost and time effective approaches. Introduction of 3D printing has led to printing micro and nanoscale structures including tissues and organelles, bioelectric sensors and devices, artificial bones and transplants, microfluidic devices, batteries and various other biomaterials. Various microfabrication processes have been developed to fabricate micro components and assemblies at lab scale. 3D Fabrication processes that can accommodate the functional and geometrical requirements to realize complicated structures are becoming feasible through advances in additive manufacturing. This advancement could lead to simpler development mechanisms of novel components and devices exhibiting complex features. For instance, development of microstructure electrodes that can penetrate the epidermis of the skin to collect the bio potential signal may prove very effective than the electrodes that measure signal from the skin's surface. The micro and nanostructures will have to possess extraordinary material and mechanical properties for its dexterity in the applications. A substantial amount of research being pursued on stretchable and flexible devices based on PDMA, textiles, and organic electronics. Despite the numerous advantages these substrates and techniques could solely offer, 3D printing enables a multi-dimensional approach towards finer and complex applications. This review emphasizes the use of 3D printing to fabricate micro and nanostructures for that can be applied for human healthcare.

  20. Micro-and/or nano-scale patterned porous membranes, methods of making membranes, and methods of using membranes

    KAUST Repository

    Wang, Xianbin; Chen, Wei; Wang, Zhihong; Zhang, Xixiang; Yue, Weisheng; Lai, Zhiping

    2015-01-01

    Embodiments of the present disclosure provide for materials that include a pre-designed patterned, porous membrane (e.g., micro- and/or nano-scale patterned), structures or devices that include a pre-designed patterned, porous membrane, methods of making pre-designed patterned, porous membranes, methods of separation, and the like.

  1. Micro-and/or nano-scale patterned porous membranes, methods of making membranes, and methods of using membranes

    KAUST Repository

    Wang, Xianbin

    2015-01-22

    Embodiments of the present disclosure provide for materials that include a pre-designed patterned, porous membrane (e.g., micro- and/or nano-scale patterned), structures or devices that include a pre-designed patterned, porous membrane, methods of making pre-designed patterned, porous membranes, methods of separation, and the like.

  2. Advanced MicroObserver UGS integration with and cueing of the BattleHawk squad level loitering munition and UAV

    Science.gov (United States)

    Steadman, Bob; Finklea, John; Kershaw, James; Loughman, Cathy; Shaffner, Patti; Frost, Dean; Deller, Sean

    2014-06-01

    Textron's Advanced MicroObserver(R) is a next generation remote unattended ground sensor system (UGS) for border security, infrastructure protection, and small combat unit security. The original MicroObserver(R) is a sophisticated seismic sensor system with multi-node fusion that supports target tracking. This system has been deployed in combat theaters. The system's seismic sensor nodes are uniquely able to be completely buried (including antennas) for optimal covertness. The advanced version adds a wireless day/night Electro-Optic Infrared (EOIR) system, cued by seismic tracking, with sophisticated target discrimination and automatic frame capture features. Also new is a field deployable Gateway configurable with a variety of radio systems and flexible networking, an important upgrade that enabled the research described herein. BattleHawkTM is a small tube launched Unmanned Air Vehicle (UAV) with a warhead. Using transmitted video from its EOIR subsystem an operator can search for and acquire a target day or night, select a target for attack, and execute terminal dive to destroy the target. It is designed as a lightweight squad level asset carried by an individual infantryman. Although BattleHawk has the best loiter time in its class, it's still relatively short compared to large UAVs. Also it's a one-shot asset in its munition configuration. Therefore Textron Defense Systems conducted research, funded internally, to determine if there was military utility in having the highly persistent MicroObserver(R) system cue BattleHawk's launch and vector it to beyond visual range targets for engagement. This paper describes that research; the system configuration implemented, and the results of field testing that was performed on a government range early in 2013. On the integrated system that was implemented, MicroObserver(R) seismic detections activated that system's camera which then automatically captured images of the target. The geo-referenced and time-tagged Micro

  3. Optimal Control of Micro Grid Operation Mode Seamless Switching Based on Radau Allocation Method

    Science.gov (United States)

    Chen, Xiaomin; Wang, Gang

    2017-05-01

    The seamless switching process of micro grid operation mode directly affects the safety and stability of its operation. According to the switching process from island mode to grid-connected mode of micro grid, we establish a dynamic optimization model based on two grid-connected inverters. We use Radau allocation method to discretize the model, and use Newton iteration method to obtain the optimal solution. Finally, we implement the optimization mode in MATLAB and get the optimal control trajectory of the inverters.

  4. A conformation-induced fluorescence method for microRNA detection

    DEFF Research Database (Denmark)

    Aw, Sherry S; Tang, Melissa Xm; Teo, Yin Nah

    2016-01-01

    and quantify microRNAs may aid research into novel aspects of microRNA biology and contribute to the development of diagnostics. By introducing an additional stem loop into the fluorescent RNA Spinach and altering its 3' and 5' ends, we have generated a new RNA, Pandan, that functions as the basis for a micro......MicroRNAs play important roles in a large variety of biological systems and processes through their regulation of target mRNA expression, and show promise as clinical biomarkers. However, their small size presents challenges for tagging or direct detection. Innovation in techniques to sense......RNA sensor. Pandan contains two sequence-variable stem loops that encode complementary sequence for a target microRNA of interest. In its sensor form, it requires the binding of a target microRNA in order to reconstitute the RNA scaffold for fluorophore binding and fluorescence. Binding of the target micro...

  5. Modified Dispersive Liquid-Liquid Micro Extraction Using Green Solvent for Determination of Polycyclic Aromatic Hydrocarbons (PAHs) in Vegetable Samples

    International Nuclear Information System (INIS)

    Kin, C.M.; Shing, W.L.

    2016-01-01

    According to International Agency for Research on Cancer (IARC), most of Polycyclic Aromatic Hydrocarbons (PAHs) known as genotoxic human carcinogen and mutagenic. PAHs represent as poorly degradable pollutants that exist in soils, sediments, surface water and atmosphere. A simple, rapid and sensitive extraction method termed modified Dispersive Liquid-Liquid Micro extraction (DLLME) using green solvent was developed to determine PAHs in vegetable samples namely radish, cabbage and cucumber prior to Gas Chromatography Flame Ionization Detection (GC-FID). The extraction method is based on replacing chlorinated organic extraction solvent in the conventional DLLME with low toxic solvent, 1-bromo-3-methylbutane without using dispersive solvent. Several experimental factors such as type and volume of extraction solvents, extraction time, confirmation of 12 PAHs by GC-MS, recovery percentages on vegetable samples and the comparative analysis with conventional DLLME were carried out. Both DLLME were successfully extracted 12 types of PAHs. In modified DLLME, the recoveries of the analytes obtained were in a range of 72.72 - 88.07 % with RSD value below 7.5 % which is comparable to the conventional DLLME. The use of microliter of low toxic extraction solvent without addition of dispersive solvent caused the method is economic and environmental friendly which is fulfill the current requirement, green chemistry based analytical method. (author)

  6. A novel automatic flow method with direct-injection photometric detector for determination of dissolved reactive phosphorus in wastewater and freshwater samples.

    Science.gov (United States)

    Koronkiewicz, Stanislawa; Trifescu, Mihaela; Smoczynski, Lech; Ratnaweera, Harsha; Kalinowski, Slawomir

    2018-02-12

    The novel automatic flow system, direct-injection detector (DID) integrated with multi-pumping flow system (MPFS), dedicated for the photometric determination of orthophosphates in wastewater and freshwater samples is for the first time described. All reagents and the sample were injected simultaneously, in counter-current into the reaction-detection chamber by the system of specially selected for this purpose solenoid micro-pumps. The micro-pumps provided good precision and accuracy of the injected volumes. For the determination of orthophosphates, the molybdenum blue method was employed. The developed method can be used to detect orthophosphate in the range 0.1-12 mg L -1 , with the repeatability (RSD) about 2.2% at 4 mg L -1 and a very high injection throughput of 120 injections h -1 . It was possible to achieve a very small consumption of reagents (10 μL of ammonium molybdate and 10 μL of ascorbic acid) and sample (20 μL). The volume of generated waste was only 440 μL per analysis. The method has been successfully applied, giving a good accuracy, to determination of orthophosphates in complex matrix samples: treated wastewater, lake water and reference sample of groundwater. The developed system is compact, small in both size and weight, requires 12 V in supply voltage, which are desirable for truly portable equipment used in routine analysis. The simplicity of the system should result in its greater long-time reliability comparing to other flow methods previously described.

  7. Determination of phthalate esters from environmental water samples by micro-solid-phase extraction using TiO2 nanotube arrays before high-performance liquid chromatography.

    Science.gov (United States)

    Zhou, Qingxiang; Fang, Zhi; Liao, Xiangkun

    2015-07-01

    We describe a highly sensitive micro-solid-phase extraction method for the pre-concentration of six phthalate esters utilizing a TiO2 nanotube array coupled to high-performance liquid chromatography with a variable-wavelength ultraviolet visible detector. The selected phthalate esters included dimethyl phthalate, diethyl phthalate, dibutyl phthalate, butyl benzyl phthalate, bis(2-ethylhexyl)phthalate and dioctyl phthalate. The factors that would affect the enrichment, such as desorption solvent, sample pH, salting-out effect, extraction time and desorption time, were optimized. Under the optimum conditions, the linear range of the proposed method was 0.3-200 μg/L. The limits of detection were 0.04-0.2 μg/L (S/N = 3). The proposed method was successfully applied to the determination of six phthalate esters in water samples and satisfied spiked recoveries were achieved. These results indicated that the proposed method was appropriate for the determination of trace phthalate esters in environmental water samples. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Research on Laser Micro Polishing of SLS Technology Sintered Iron-Based Powder Surface

    OpenAIRE

    Gerda Vaitkūnaitė; Vladislav Markovič; Olegas Černašėjus

    2015-01-01

    The article analyzes laser micro polishing of 1.2083 steel samples produced applying selective laser sintering (SLS) method. The study has evaluated the distribution of the shape, size and temperature of the laser beam treated area in the surface layer of sintered and laser polished samples. Experimental tests have shown the impact of the technical parameters of laser micro polishing on the width and hardness of the impact zone of the treated sample. The microstructure analysis of laser treat...

  9. Advanced Curation: Solving Current and Future Sample Return Problems

    Science.gov (United States)

    Fries, M.; Calaway, M.; Evans, C.; McCubbin, F.

    2015-01-01

    Advanced Curation is a wide-ranging and comprehensive research and development effort at NASA Johnson Space Center that identifies and remediates sample related issues. For current collections, Advanced Curation investigates new cleaning, verification, and analytical techniques to assess their suitability for improving curation processes. Specific needs are also assessed for future sample return missions. For each need, a written plan is drawn up to achieve the requirement. The plan draws while upon current Curation practices, input from Curators, the analytical expertise of the Astromaterials Research and Exploration Science (ARES) team, and suitable standards maintained by ISO, IEST, NIST and other institutions. Additionally, new technologies are adopted on the bases of need and availability. Implementation plans are tested using customized trial programs with statistically robust courses of measurement, and are iterated if necessary until an implementable protocol is established. Upcoming and potential NASA missions such as OSIRIS-REx, the Asteroid Retrieval Mission (ARM), sample return missions in the New Frontiers program, and Mars sample return (MSR) all feature new difficulties and specialized sample handling requirements. The Mars 2020 mission in particular poses a suite of challenges since the mission will cache martian samples for possible return to Earth. In anticipation of future MSR, the following problems are among those under investigation: What is the most efficient means to achieve the less than 1.0 ng/sq cm total organic carbon (TOC) cleanliness required for all sample handling hardware? How do we maintain and verify cleanliness at this level? The Mars 2020 Organic Contamination Panel (OCP) predicts that organic carbon, if present, will be present at the "one to tens" of ppb level in martian near-surface samples. The same samples will likely contain wt% perchlorate salts, or approximately 1,000,000x as much perchlorate oxidizer as organic carbon

  10. The Evaluation of Micro Teaching Method Used in the Training of Primary School Teachers in Turkey

    Science.gov (United States)

    Musa, Taskaya Serdarhan

    2014-01-01

    Micro teaching, one of the most frequently used methods in the pre-service education of teachers, is used in many lectures for the training of teachers in the faculties of education in Turkey. Micro teaching is a teaching method which is especially used in the pre-service training of teachers and it aims to train prospective teachers by making…

  11. Active Fail-Safe Micro-Array Flow Control for Advanced Embedded Propulsion Systems

    Science.gov (United States)

    Anderson, Bernhard H.; Mace, James L.; Mani, Mori

    2009-01-01

    The primary objective of this research effort was to develop and analytically demonstrate enhanced first generation active "fail-safe" hybrid flow-control techniques to simultaneously manage the boundary layer on the vehicle fore-body and to control the secondary flow generated within modern serpentine or embedded inlet S-duct configurations. The enhanced first-generation technique focused on both micro-vanes and micro-ramps highly-integrated with micro -jets to provide nonlinear augmentation for the "strength' or effectiveness of highly-integrated flow control systems. The study focused on the micro -jet mass flow ratio (Wjet/Waip) range from 0.10 to 0.30 percent and jet total pressure ratios (Pjet/Po) from 1.0 to 3.0. The engine bleed airflow range under study represents about a 10 fold decrease in micro -jet airflow than previously required. Therefore, by pre-conditioning, or injecting a very small amount of high-pressure jet flow into the vortex generated by the micro-vane and/or micro-ramp, active flow control is achieved and substantial augmentation of the controlling flow is realized.

  12. Accurate micro Hall effect measurements on scribe line pads

    DEFF Research Database (Denmark)

    Østerberg, Frederik Westergaard; Petersen, Dirch Hjorth; Wang, Fei

    2009-01-01

    Hall mobility and sheet carrier density are important parameters to monitor in advanced semiconductor production. If micro Hall effect measurements are done on small pads in scribe lines, these parameters may be measured without using valuable test wafers. We report how Hall mobility can...... be extracted from micro four-point measurements performed on a rectangular pad. The dimension of the investigated pad is 400 × 430 ¿m2, and the probe pitches range from 20 ¿m to 50 ¿m. The Monte Carlo method is used to find the optimal way to perform the Hall measurement and extract Hall mobility most...

  13. Integrated microfabricated biodevices. New advances in sample preparation (T2)

    International Nuclear Information System (INIS)

    Guttman, A.

    2002-01-01

    Full text: Interdisciplinary science and technologies have converged in the past few years to create exciting challenges and opportunities, which involve novel, integrated microfabricated systems, facilitating large-scale analytical applications. These new devices are referred to as lab-on-a-chip or micro Total Analysis Systems (uTAS). Their development involves both established and evolving technologies, which include microlithography, micromachining, micro-electromechanical systems (MEMS) technology, microfluidics and nanotechnology. The advent of this extremely powerful and rapid analysis technique opens up new horizons in analytical chemistry and molecular biology, capable of revealing global changes in gene expression levels by enabling genome, proteome and metabolome analysis on microchips. This presentation will provide an overview of the key device subject areas and the basic interdisciplinary technologies. It will also give a better understanding of how to utilize these miniaturized technologies as well as to provide appropriate technical solutions to problems perceived as being more fundamental. Theoretical and practical aspects of integrating sample preparation/purification and analysis units with chemical and biochemical reactors in monolithic microdevices are going to be thoroughly discussed. Important applications for this novel 'synergized' technology in high throughput analysis of biologically important molecules will also be addressed. (author)

  14. Advanced differential quadrature methods

    CERN Document Server

    Zong, Zhi

    2009-01-01

    Modern Tools to Perform Numerical DifferentiationThe original direct differential quadrature (DQ) method has been known to fail for problems with strong nonlinearity and material discontinuity as well as for problems involving singularity, irregularity, and multiple scales. But now researchers in applied mathematics, computational mechanics, and engineering have developed a range of innovative DQ-based methods to overcome these shortcomings. Advanced Differential Quadrature Methods explores new DQ methods and uses these methods to solve problems beyond the capabilities of the direct DQ method.After a basic introduction to the direct DQ method, the book presents a number of DQ methods, including complex DQ, triangular DQ, multi-scale DQ, variable order DQ, multi-domain DQ, and localized DQ. It also provides a mathematical compendium that summarizes Gauss elimination, the Runge-Kutta method, complex analysis, and more. The final chapter contains three codes written in the FORTRAN language, enabling readers to q...

  15. Lithographic measurement of EUV flare in the 0.3-NA Micro Exposure Tool optic at the Advanced Light Source

    International Nuclear Information System (INIS)

    Cain, Jason P.; Naulleau, Patrick; Spanos, Costas J.

    2005-01-01

    The level of flare present in a 0.3-NA EUV optic (the MET optic) at the Advanced Light Source at Lawrence Berkeley National Laboratory is measured using a lithographic method. Photoresist behavior at high exposure doses makes analysis difficult. Flare measurement analysis under scanning electron microscopy (SEM) and optical microscopy is compared, and optical microscopy is found to be a more reliable technique. In addition, the measured results are compared with predictions based on surface roughness measurement of the MET optical elements. When the fields in the exposure matrix are spaced far enough apart to avoid influence from surrounding fields and the data is corrected for imperfect mask contrast and aerial image proximity effects, the results match predicted values quite well. The amount of flare present in this optic ranges from 4.7% for 2 (micro)m features to 6.8% for 500 nm features

  16. Flexible micro-OCT endobronchial probe for imaging of mucociliary transport (Conference Presentation)

    Science.gov (United States)

    Cui, Dongyao; Chu, Kengyeh K.; Unglert, Carolin I.; Ford, Tim N.; Carruth, Robert W.; Hyun, Daryl; Singh, Kanwarpal; Birket, Susan E.; Solomon, George M.; Rowe, Steve M.; Tearney, Guillermo J.

    2016-03-01

    Mucociliary clearance (MCC) plays a significant role in maintaining the health of human respiratory system by eliminating foreign particles trapped within mucus. Failure of this mechanism in diseases such as cystic fibrosis and chronic obstructive pulmonary disease (COPD) leads to airway blockage and lung infection, causing morbidity and mortality. The volume of airway mucus and the periciliary liquid encapsulating the cilia, in addition to ciliary beat frequency and velocity of mucociliary transport, are vital parameters of airway health. However, the diagnosis of disease pathogenesis and advances of novel therapeutics are hindered by the lack of tools for visualization of ciliary function in vivo. Our laboratory has previously developed a 1-µm resolution optical coherence tomography method, termed Micro-OCT, which is capable of visualizing mucociliary transport and quantitatively capturing epithelial functional metrics. We have also miniaturized Micro-OCT optics in a first-generation rigid 4mm Micro-OCT endoscope utilizing a common-path design and an apodizing prism configuration to produce an annular profile sample beam, and reported the first in vivo visualization of mucociliary transport in swine. We now demonstrate a flexible 2.5 mm Micro-OCT probe that can be inserted through the instrument channel of standard flexible bronchoscopes, allowing bronchoscopic navigation to smaller airways and greatly improving clinical utility. Longitudinal scanning over a field of view of more than 400 µm at a frame rate of 40 Hz was accomplished with a driveshaft transduced by a piezo-electric stack motor. We present characterization and imaging results from the flexible micro-OCT probe and progress towards clinical translation. The ability of the bronchoscope-compatible micro-OCT probe to image mucus clearance and epithelial function will enable studies of cystic fibrosis pathogenesis in small airways, provide diagnosis of mucociliary clearance disorders, and allow

  17. Laser sampling

    International Nuclear Information System (INIS)

    Gorbatenko, A A; Revina, E I

    2015-01-01

    The review is devoted to the major advances in laser sampling. The advantages and drawbacks of the technique are considered. Specific features of combinations of laser sampling with various instrumental analytical methods, primarily inductively coupled plasma mass spectrometry, are discussed. Examples of practical implementation of hybrid methods involving laser sampling as well as corresponding analytical characteristics are presented. The bibliography includes 78 references

  18. Evaluation of laboratory powder X-ray micro-diffraction for applications in the fields of cultural heritage and forensic science.

    Science.gov (United States)

    Svarcová, Silvie; Kocí, Eva; Bezdicka, Petr; Hradil, David; Hradilová, Janka

    2010-09-01

    The uniqueness and limited amounts of forensic samples and samples from objects of cultural heritage together with the complexity of their composition requires the application of a wide range of micro-analytical methods, which are non-destructive to the samples, because these must be preserved for potential late revision. Laboratory powder X-ray micro-diffraction (micro-XRD) is a very effective non-destructive technique for direct phase analysis of samples smaller than 1 mm containing crystal constituents. It compliments optical and electron microscopy with elemental micro-analysis, especially in cases of complicated mixtures containing phases with similar chemical composition. However, modification of X-ray diffraction to the micro-scale together with its application for very heterogeneous real samples leads to deviations from the standard procedure. Knowledge of both the limits and the phenomena which can arise during the analysis is crucial for the meaningful and proper application of the method. We evaluated basic limits of micro-XRD equipped with a mono-capillary with an exit diameter of 0.1 mm, for example the size of irradiated area, appropriate grain size, and detection limits allowing identification of given phases. We tested the reliability and accuracy of quantitative phase analysis based on micro-XRD data in comparison with conventional XRD (reflection and transmission), carrying out experiments with two-phase model mixtures simulating historic colour layers. Furthermore, we demonstrate the wide use of micro-XRD for investigation of various types of micro-samples (contact traces, powder traps, colour layers) and we show how to enhance data quality by proper choice of experiment geometry and conditions.

  19. Development of advanced MCR task analysis methods

    International Nuclear Information System (INIS)

    Na, J. C.; Park, J. H.; Lee, S. K.; Kim, J. K.; Kim, E. S.; Cho, S. B.; Kang, J. S.

    2008-07-01

    This report describes task analysis methodology for advanced HSI designs. Task analyses was performed by using procedure-based hierarchical task analysis and task decomposition methods. The results from the task analysis were recorded in a database. Using the TA results, we developed static prototype of advanced HSI and human factors engineering verification and validation methods for an evaluation of the prototype. In addition to the procedure-based task analysis methods, workload estimation based on the analysis of task performance time and analyses for the design of information structure and interaction structures will be necessary

  20. Deployable micro-traps to sequester motile bacteria

    Science.gov (United States)

    di Giacomo, Raffaele; Krödel, Sebastian; Maresca, Bruno; Benzoni, Patrizia; Rusconi, Roberto; Stocker, Roman; Daraio, Chiara

    2017-04-01

    The development of strategies to reduce the load of unwanted bacteria is a fundamental challenge in industrial processing, environmental sciences and medical applications. Here, we report a new method to sequester motile bacteria from a liquid, based on passive, deployable micro-traps that confine bacteria using micro-funnels that open into trapping chambers. Even in low concentrations, micro-traps afford a 70% reduction in the amount of bacteria in a liquid sample, with a potential to reach >90% as shown by modelling improved geometries. This work introduces a new approach to contain the growth of bacteria without chemical means, an advantage of particular importance given the alarming growth of pan-drug-resistant bacteria.

  1. Comparison of 3 methods on fabricating micro- /nano- structured surface on 3D mold cavity

    DEFF Research Database (Denmark)

    Zhang, Yang; Hansen, Hans Nørgaard; Bissacco, Giuliano

    2015-01-01

    The methods to manufacture micro- or nano- structures on surfaces have been an area of intense investigation. Demands are shown for technologies for surface structuring on real 3D parts in many fields. However, most technologies for the fabrication of micro-structured functional surfaces are still...... limited to flat or simple shaped geometries. In this paper, 3 approaches for fabricating micro and nano- structured surfaces on a mold cavity for injection moulding are investigated and compared. The first approach is to use pre-fabricated plate with micro-structured surface as an insert for the mold......, in this way micro holes (Ø4 μm) was obtained. The second approach is to produce the cavity part using anodizing process chain, and in this way sub-micro structures can be obtained all over the cavity surface. The third approach is to machine the surface inside the cavity directly by femtosecond laser combined...

  2. Isolation of microRNA targets using biotinylated synthetic microRNAs

    DEFF Research Database (Denmark)

    Ørom, Ulf Andersson; Lund, Anders H

    2007-01-01

    MicroRNAs are small regulatory RNAs found in multicellular organisms where they post-transcriptionally regulate gene expression. In animals, microRNAs bind mRNAs via incomplete base pairings making the identification of microRNA targets inherently difficult. Here, we present a detailed method...... for experimental identification of microRNA targets based on affinity purification of tagged microRNAs associated with their targets. Udgivelsesdato: 2007-Oct...

  3. Detection of viability of micro-algae cells by optofluidic hologram pattern.

    Science.gov (United States)

    Wang, Junsheng; Yu, Xiaomei; Wang, Yanjuan; Pan, Xinxiang; Li, Dongqing

    2018-03-01

    A rapid detection of micro-algae activity is critical for analysis of ship ballast water. A new method for detecting micro-algae activity based on lens-free optofluidic holographic imaging is presented in this paper. A compact lens-free optofluidic holographic imaging device was developed. This device is mainly composed of a light source, a small through-hole, a light propagation module, a microfluidic chip, and an image acquisition and processing module. The excited light from the light source passes through a small hole to reach the surface of the micro-algae cells in the microfluidic chip, and a holographic image is formed by the diffraction light of surface of micro-algae cells. The relation between the characteristics in the hologram pattern and the activity of micro-algae cells was investigated by using this device. The characteristics of the hologram pattern were extracted to represent the activity of micro-algae cells. To demonstrate the accuracy of the presented method and device, four species of micro-algae cells were employed as the test samples and the comparison experiments between the alive and dead cells of four species of micro-algae were conducted. The results show that the developed method and device can determine live/dead microalgae cells accurately.

  4. A new method for calculating gas content of coal reservoirs with consideration of a micro-pore overpressure environment

    Directory of Open Access Journals (Sweden)

    Jinxing Song

    2017-05-01

    Full Text Available When the gas content of a coal reservoir is calculated, the reservoir pressure measured by well logging and well testing is generally used for inversion calculation instead of gas pressure. However, the calculation result is not accurate because the reservoir pressure is not equal to the gas pressure in overpressure environments. In this paper, coal samples of different ranks in Shanxi and Henan are collected for testing the capillary pressure of coal pores. Based on the formation process of CBM reservoirs and the hydrocarbon generation and expulsion history of coal beds, the forming mechanisms of micro-pore overpressure environments in coal reservoirs were analyzed. Accordingly, a new method for calculating the gas content of coal reservoirs with consideration of a micro-pore overpressure environment was developed. And it was used to calculate the gas content of No. 1 coal bed of the 2nd member of Lower Permian Shanxi Fm in the Zhongmacun Coal Mine in Jiaozuo, Henan. It is indicated that during the formation and evolution of coals, some solid organic matters were converted into gas and water, and gas–water contact is surely formed in pores. In the end, capillary pressure is generated, so the gas pressure in micro-pores is much higher than the hydrostatic column pressure, which results in a micro-pore overpressure environment. Under such an environment, gas pressure is higher than reservoir pressure, so the gas content of coal reservoirs calculated previously based on the conventional reservoir pressure evaluation are usually underestimated. It is also found that the micro-pore overpressure environment exerts a dominating effect on the CBM content calculation of 3–100 nm pores, especially that of 3–10 nm pores, but a little effect on that of pores >100 nm. In conclusion, this new method clarifies the pressure environment of CBM gas reservoirs, thereby ensuring the calculation accuracy of gas content of coal reservoirs.

  5. The micro-processor controlled process radiation monitoring system for reactor safety systems

    International Nuclear Information System (INIS)

    Mizuno, K.; Noguchi, A.; Kumagami, S.; Gotoh, Y.; Kumahara, T.; Arita, S.

    1986-01-01

    Digital computers are soon expected to be applied to various real-time safety and safety-related systems in nuclear power plants. Hitachi is now engaged in the development of a micro-processor controlled process radiation monitoring system, which operates on digital processing methods employed with a log ratemeter. A newly defined methodology of design and test procedures is being applied as a means of software program verification for these safety systems. Recently implemented micro-processor technology will help to achieve an advanced man-machine interface and highly reliable performance. (author)

  6. Evaluation of Fine Aggregate Morphology by Image Method and Its Effect on Skid-Resistance of Micro-Surfacing.

    Science.gov (United States)

    Xiao, Yue; Wang, Feng; Cui, Peide; Lei, Lei; Lin, Juntao; Yi, Mingwei

    2018-05-29

    Micro-surfacing is a widely used pavement preventive maintenance technology used all over the world, due to its advantages of fast construction, low maintenance cost, good waterproofness, and skid-resistance performance. This study evaluated the fine aggregate morphology and surface texture of micro-surfacing by AIMS (aggregate image measurement system), and explored the effect of aggregate morphology on skid-resistance of single-grade micro-surfacing. Sand patch test and British pendulum test were also used to detect skid-resistance for comparison with the image-based method. Wet abrasion test was used to measure skid-resistance durability for feasibility verification of single-grade micro-surfacing. The results show that the effect of Form2D on the skid-resistance of micro-surfacing is much stronger than that of angularity. Combining the feasibility analysis of durability and skid-resistance, 1.18⁻2.36 grade micro-surfacing meets the requirements of durability and skid-resistance at the same time. This study also determined that, compared with British pendulum test, the texture result obtained by sand patch test fits better with results of image method.

  7. Advancing the Use of Passive Sampling in Risk Assessment and Management of Sediments Contaminated with Hydrophobic Organic Chemicals: Results of an International Ex Situ Passive Sampling Interlaboratory Comparison.

    Science.gov (United States)

    Jonker, Michiel T O; van der Heijden, Stephan A; Adelman, Dave; Apell, Jennifer N; Burgess, Robert M; Choi, Yongju; Fernandez, Loretta A; Flavetta, Geanna M; Ghosh, Upal; Gschwend, Philip M; Hale, Sarah E; Jalalizadeh, Mehregan; Khairy, Mohammed; Lampi, Mark A; Lao, Wenjian; Lohmann, Rainer; Lydy, Michael J; Maruya, Keith A; Nutile, Samuel A; Oen, Amy M P; Rakowska, Magdalena I; Reible, Danny; Rusina, Tatsiana P; Smedes, Foppe; Wu, Yanwen

    2018-03-20

    This work presents the results of an international interlaboratory comparison on ex situ passive sampling in sediments. The main objectives were to map the state of the science in passively sampling sediments, identify sources of variability, provide recommendations and practical guidance for standardized passive sampling, and advance the use of passive sampling in regulatory decision making by increasing confidence in the use of the technique. The study was performed by a consortium of 11 laboratories and included experiments with 14 passive sampling formats on 3 sediments for 25 target chemicals (PAHs and PCBs). The resulting overall interlaboratory variability was large (a factor of ∼10), but standardization of methods halved this variability. The remaining variability was primarily due to factors not related to passive sampling itself, i.e., sediment heterogeneity and analytical chemistry. Excluding the latter source of variability, by performing all analyses in one laboratory, showed that passive sampling results can have a high precision and a very low intermethod variability (sampling, irrespective of the specific method used, is fit for implementation in risk assessment and management of contaminated sediments, provided that method setup and performance, as well as chemical analyses are quality-controlled.

  8. Measurement of modulation transfer function in z-axis for multi-slice spiral CT using the micro-disk method. Comparison with the bead method and examination of geometric influence

    International Nuclear Information System (INIS)

    Hara, Takanori

    2003-01-01

    Many methods of measuring the section-sensitive profile (SSP) of computed tomography (CT) by the input of a delta function have been reported. In Japan, the bead method is used as a common measurement because of the high flexibility of the multi-purpose method. However, the intensity of the response of the bead method tends to decline, creating a relatively large error in the base of SSPs. A problem is considered to be the accuracy of measurement in evaluating spatial resolution along the z-axis in multi-slice spiral/helical CT (MSCT). We therefore evaluated the modulation transfer function (MTF) by conducting research with the micro-disk method (100 μm thickness and 1.0 mmφ diameter) and the bead method (1.0 mmφ diameter) for the same input width. Moreover, in the micro-disk method, we also examined alignment, circular region of interest (ROI), and the energy characteristic. Our comparison of MTFs obtained by the micro-disk method and the bead method showed that the former resulted in a higher value and lower standard deviation. The difference was significant at p<0.01. Measurement using the micro-disk method did not show significant differences in terms of alignment and ROIs. Moreover, the energy characteristic was not indicated. This research demonstrated that the accuracy of MTF measurement with the micro-disk method was greater than that with the bead method, and it was found that there was no influence on the actual measurement level of the geometric structure with the micro-disk method. (author)

  9. The application of near-infrared spectra micro-image in the imaging analysis of biology samples

    Directory of Open Access Journals (Sweden)

    Dong Wang

    2014-07-01

    Full Text Available In this research, suitable imaging methods were used for acquiring single compound images of biology samples of chicken pectorales tissue section, tobacco dry leaf, fresh leaf and plant glandular hair, respectively. The adverse effects caused by the high water content and the thermal effect of near infrared (NIR light were effectively solved during the experiment procedures and the data processing. PCA algorithm was applied to the NIR micro-image of chicken pectorales tissue. Comparing the loading vector of PC3 with the NIR spectrum of dry albumen, the information of PC3 was confirmed to be provided mainly by protein, i.e., the 3rd score image represents the distribution trend of protein mainly. PCA algorithm was applied to the NIR micro-image of tobacco dry leaf. The information of PC2 was confirmed to be provided by carbohydrate including starch mainly. Compared to the 2nd score image of tobacco dry leaf, the compared correlation image with the reference spectrum of starch had the same distribution trend as the 2nd score image. The comparative correlation images with the reference spectra of protein, glucose, fructose and the total plant alkaloid were acquired to confirm the distribution trend of these compounds in tobacco dry leaf respectively. Comparative correlation images of fresh leaf with the reference spectra of protein, starch, fructose, glucose and water were acquired to confirm the distribution trend of these compounds in fresh leaf. Chemimap imaging of plant glandular hair was acquired to show the tubular structure clearly.

  10. Novel fabrication method for three-dimensional nanostructuring: an application to micro-optics

    International Nuclear Information System (INIS)

    Tormen, Massimo; Carpentiero, Alessandro; Ferrari, Enrico; Cojoc, Dan; Fabrizio, Enzo Di

    2007-01-01

    We propose a 3D micro and nanofabrication method with potential applications to several nanotechnology-related fields. Our approach is based on the combination of lithographic steps and isotropic wet etchings performed on a quartz or glass substrate to form 3D structures with very accurate shape control and nanometer scale surface roughness. The resulting concavities at the quartz surface are converted into convex plastic elements by hot embossing or casting techniques. Complex all-polymer refractive optical elements have been realized by this method. Upon illumination, such micro-optics focus the light into predetermined 3D distributions of focal lines and spots. The general fabrication scheme explored here is illustrated through a series of examples in optics, but is expected to offer new solutions to other fields such as medicine, microfluidics and nano-optics

  11. Micro-computed tomography assessment of human alveolar bone: bone density and three-dimensional micro-architecture.

    Science.gov (United States)

    Kim, Yoon Jeong; Henkin, Jeffrey

    2015-04-01

    Micro-computed tomography (micro-CT) is a valuable means to evaluate and secure information related to bone density and quality in human necropsy samples and small live animals. The aim of this study was to assess the bone density of the alveolar jaw bones in human cadaver, using micro-CT. The correlation between bone density and three-dimensional micro architecture of trabecular bone was evaluated. Thirty-four human cadaver jaw bone specimens were harvested. Each specimen was scanned with micro-CT at resolution of 10.5 μm. The bone volume fraction (BV/TV) and the bone mineral density (BMD) value within a volume of interest were measured. The three-dimensional micro architecture of trabecular bone was assessed. All the parameters in the maxilla and the mandible were subject to comparison. The variables for the bone density and the three-dimensional micro architecture were analyzed for nonparametric correlation using Spearman's rho at the significance level of p architecture parameters were consistently higher in the mandible, up to 3.3 times greater than those in the maxilla. The most linear correlation was observed between BV/TV and BMD, with Spearman's rho = 0.99 (p = .01). Both BV/TV and BMD were highly correlated with all micro architecture parameters with Spearman's rho above 0.74 (p = .01). Two aspects of bone density using micro-CT, the BV/TV and BMD, are highly correlated with three-dimensional micro architecture parameters, which represent the quality of trabecular bone. This noninvasive method may adequately enhance evaluation of the alveolar bone. © 2013 Wiley Periodicals, Inc.

  12. Advanced analysis methods in particle physics

    Energy Technology Data Exchange (ETDEWEB)

    Bhat, Pushpalatha C.; /Fermilab

    2010-10-01

    Each generation of high energy physics experiments is grander in scale than the previous - more powerful, more complex and more demanding in terms of data handling and analysis. The spectacular performance of the Tevatron and the beginning of operations of the Large Hadron Collider, have placed us at the threshold of a new era in particle physics. The discovery of the Higgs boson or another agent of electroweak symmetry breaking and evidence of new physics may be just around the corner. The greatest challenge in these pursuits is to extract the extremely rare signals, if any, from huge backgrounds arising from known physics processes. The use of advanced analysis techniques is crucial in achieving this goal. In this review, I discuss the concepts of optimal analysis, some important advanced analysis methods and a few examples. The judicious use of these advanced methods should enable new discoveries and produce results with better precision, robustness and clarity.

  13. An Advanced Actuator Line Method for Wind Energy Applications and Beyond: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Churchfield, Matthew; Schreck, Scott; Martinez-Tossas, Luis A.; Meneveau, Charles; Spalart, Philippe R.

    2017-03-24

    The actuator line method to represent rotor aerodynamics within computational fluid dynamics has been in use for over a decade. This method applies a body force to the flow field along rotating lines corresponding to the individual rotor blades and employs tabular airfoil data to compute the force distribution. The actuator line method is attractive because compared to blade-resolved simulations, the required mesh is much simpler and the computational cost is lower. This work proposes a higher fidelity variant of the actuator line method meant to fill the space between current actuator line and blade-resolved simulations. It contains modifications in two key areas. The first is that of freestream velocity vector estimation along the line, which is necessary to compute the lift and drag along the line using tabular airfoil data. Most current methods rely on point sampling in which the location of sampling is ambiguous. Here we test a velocity sampling method that uses a properly weighted integral over space, removing this ambiguity. The second area of improvement is the function used to project the one-dimensional actuator line force onto the three-dimensional fluid mesh as a body force. We propose and test a projection function that spreads the force over a region that looks something like a real blade with the hope that it will produce the blade local and near wake flow features with more accuracy and higher fidelity. Our goal is that between these two improvements, not only will the flow field predictions be enhanced, but also the spanwise loading will be made more accurate. We refer to this combination of improvements as the advanced actuator line method. We apply these improvements to two different wind turbine cases. Although there is a strong wind energy motivation in our work, there is no reason these advanced actuator line ideas cannot be used in other applications, such as helicopter rotors.

  14. Advancements in ion beam figuring of very thin glass plates (Conference Presentation)

    Science.gov (United States)

    Civitani, M.; Ghigo, M.; Hołyszko, J.; Vecchi, G.; Basso, S.; Cotroneo, V.; DeRoo, C. T.; Schwartz, E. D.; Reid, P. B.

    2017-09-01

    The high-quality surface characteristics, both in terms of figure error and of micro-roughness, required on the mirrors of a high angular resolution x-ray telescope are challenging, but in principle well suited with a deterministic and non-contact process like the ion beam figuring. This process has been recently proven to be compatible even with very thin (thickness around 0.4mm) sheet of glasses (like D263 and Eagle). In the last decade, these types of glass have been investigated as substrates for hot slumping, with residual figure errors of hundreds of nanometres. In this view, the mirrors segments fabrication could be envisaged as a simple two phases process: a first replica step based on hot slumping (direct/indirect) followed by an ion beam figuring which can be considered as a post-fabrication correction method. The first ion beam figuring trials, realized on flat samples, showed that the micro-roughness is not damaged but a deeper analysis is necessary to characterize and eventually control/compensate the glass shape variations. In this paper, we present the advancements in the process definition, both on flat and slumped glass samples.

  15. Independent random sampling methods

    CERN Document Server

    Martino, Luca; Míguez, Joaquín

    2018-01-01

    This book systematically addresses the design and analysis of efficient techniques for independent random sampling. Both general-purpose approaches, which can be used to generate samples from arbitrary probability distributions, and tailored techniques, designed to efficiently address common real-world practical problems, are introduced and discussed in detail. In turn, the monograph presents fundamental results and methodologies in the field, elaborating and developing them into the latest techniques. The theory and methods are illustrated with a varied collection of examples, which are discussed in detail in the text and supplemented with ready-to-run computer code. The main problem addressed in the book is how to generate independent random samples from an arbitrary probability distribution with the weakest possible constraints or assumptions in a form suitable for practical implementation. The authors review the fundamental results and methods in the field, address the latest methods, and emphasize the li...

  16. Cell behaviors on micro-patterned porous thin films

    International Nuclear Information System (INIS)

    Phong, Ho Quoc; Wang Shuling; Wang, Meng-Jiy

    2010-01-01

    Thin polymer films with patterned surfaces have drawn tremendous attention in manufacturing advanced electronic, mechanical devices and in biomaterials due to the advantageous properties such as mechanical strength, chemical resistance and optic transparency. The applications can be extended to the fields such as catalysts, antireflection coatings, template for inorganic growth masks, and substrates for cell culturing providing the patterned surface containing micron-sized features. Various methods have been used to fabricate polymers with micro-patterned surfaces such as photolithographic, ink-jet printing, nonsolvent, spin coating in a dry environment, self-organization, and the condensation of monodisperse water droplet on the polymer solution. The physiological functions of mature cells depend on the microenvironment/niche surrounding which can provide proper factors to regulate cell proliferation and differentiation. While designing appropriate scaffolds for tissue engineering, the microstructure is one of the most important factors to be considered. In this work, a facile single-step phase separation method was used to create micro-patterned polymer thin films with concaves or convexes with sizes ranged from 7 to 70 μm. The effects of water content, casting volume and the addition of surfactant on the distribution of pores and substrate morphology were examined. Moreover, detailed observations of fibroblast cells on the micro-patterned thin films were presented to compare and elucidate the roles of surface micro-features and chemical functionalities.

  17. A novel method for calculating the dynamic capillary force and correcting the pressure error in micro-tube experiment.

    Science.gov (United States)

    Wang, Shuoliang; Liu, Pengcheng; Zhao, Hui; Zhang, Yuan

    2017-11-29

    Micro-tube experiment has been implemented to understand the mechanisms of governing microcosmic fluid percolation and is extensively used in both fields of micro electromechanical engineering and petroleum engineering. The measured pressure difference across the microtube is not equal to the actual pressure difference across the microtube. Taking into account the additional pressure losses between the outlet of the micro tube and the outlet of the entire setup, we propose a new method for predicting the dynamic capillary pressure using the Level-set method. We first demonstrate it is a reliable method for describing microscopic flow by comparing the micro-model flow-test results against the predicted results using the Level-set method. In the proposed approach, Level-set method is applied to predict the pressure distribution along the microtube when the fluids flow along the microtube at a given flow rate; the microtube used in the calculation has the same size as the one used in the experiment. From the simulation results, the pressure difference across a curved interface (i.e., dynamic capillary pressure) can be directly obtained. We also show that dynamic capillary force should be properly evaluated in the micro-tube experiment in order to obtain the actual pressure difference across the microtube.

  18. A method of language sampling

    DEFF Research Database (Denmark)

    Rijkhoff, Jan; Bakker, Dik; Hengeveld, Kees

    1993-01-01

    In recent years more attention is paid to the quality of language samples in typological work. Without an adequate sampling strategy, samples may suffer from various kinds of bias. In this article we propose a sampling method in which the genetic criterion is taken as the most important: samples...... created with this method will reflect optimally the diversity of the languages of the world. On the basis of the internal structure of each genetic language tree a measure is computed that reflects the linguistic diversity in the language families represented by these trees. This measure is used...... to determine how many languages from each phylum should be selected, given any required sample size....

  19. Microwave-assisted synthesis and optical properties of cuprous oxide micro/nanocrystals

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Dandan [Key Laboratory of Processing and Testing Technology of Glass and Functional Ceramics of Shandong Province, Qilu University of Technology, Jinan 250353 (China); Du, Yi, E-mail: duyi234@126.com [Key Laboratory of Processing and Testing Technology of Glass and Functional Ceramics of Shandong Province, Qilu University of Technology, Jinan 250353 (China); Tian, Xiuying, E-mail: xiuyingt@yahoo.com [Department of Chemistry and Materials Science, Hunan Institute of Humanities Science and Technology, Loudi 417000 (China); Li, Zhongfu; Chen, Zhongtao; Zhu, Chaofeng [Key Laboratory of Processing and Testing Technology of Glass and Functional Ceramics of Shandong Province, Qilu University of Technology, Jinan 250353 (China)

    2014-12-15

    Graphical abstract: Cuprous oxide micro/nanocrystals were fabricated by a facile and green microwave-assisted method using soluble starch as reductant and dispersant. Spheres with the diameter of about 100 and 600 nm, octahedron and truncated octahedron with the edge length of about 0.8–3 μm cuprous oxide micro/nanocrystals were successfully obtained. Microwave heating was proved to be a efficient method and was advantageous to the homogeneous nucleation. Growth mechanism of the prepared Cu{sub 2}O microcrystals were investigated carefully. Furthermore, the optical properties of the prepared cuprous oxide microcrystals were investigated by UV–vis diffuse reflectance spectroscopy, demonstrating that their band gaps of obtained samples were 1.96–2.07 eV, assigned to their different sizes and morphologies. - Abstract: Cuprous oxide micro/nanocrystals were fabricated by a facile and green microwave-assisted method using soluble starch as reductant and dispersant. It was observed that the addition amounts of NaOH had a prominent effect on the morphologies and size of cuprous oxide products, and microwave heating was proved to be a efficient method and was advantageous to the homogeneous nucleation. The as-obtained samples were characterized by X-ray diffraction (XRD), and field-emission scanning electron microscopy (FESEM). The results indicated that the samples were pure cuprous oxide. Spheres with the diameter of about 100 and 600 nm, octahedron and truncated octahedron with the edge length of about 0.8–3 μm cuprous oxide micro/nanocrystals were successfully obtained. Furthermore, the UV–vis diffuse reflectance spectroscopy was used to investigate the optical properties of the prepared cuprous oxide microcrystals, demonstrating that their band gaps of obtained samples were 1.96–2.07 eV, assigned to their different sizes and morphologies.

  20. Optimization of single plate-serial dilution spotting (SP-SDS) with sample anchoring as an assured method for bacterial and yeast cfu enumeration and single colony isolation from diverse samples.

    Science.gov (United States)

    Thomas, Pious; Sekhar, Aparna C; Upreti, Reshmi; Mujawar, Mohammad M; Pasha, Sadiq S

    2015-12-01

    We propose a simple technique for bacterial and yeast cfu estimations from diverse samples with no prior idea of viable counts, designated as single plate-serial dilution spotting (SP-SDS) with the prime recommendation of sample anchoring (10 0 stocks). For pure cultures, serial dilutions were prepared from 0.1 OD (10 0 ) stock and 20 μl aliquots of six dilutions (10 1 -10 6 ) were applied as 10-15 micro-drops in six sectors over agar-gelled medium in 9-cm plates. For liquid samples 10 0 -10 5 dilutions, and for colloidal suspensions and solid samples (10% w/v), 10 1 -10 6 dilutions were used. Following incubation, at least one dilution level yielded 6-60 cfu per sector comparable to the standard method involving 100 μl samples. Tested on diverse bacteria, composite samples and Saccharomyces cerevisiae , SP-SDS offered wider applicability over alternative methods like drop-plating and track-dilution for cfu estimation, single colony isolation and culture purity testing, particularly suiting low resource settings.

  1. Sampling and analytical procedures for the determination of VOCs released into air from natural and anthropogenic sources: A comparison between SPME (Solid Phase Micro Extraction) and ST (Solid Trap) methods

    International Nuclear Information System (INIS)

    Tassi, F.; Capecchiacci, F.; Buccianti, A.; Vaselli, O.

    2012-01-01

    In the present study, two sampling and analytical methods for VOC determination in fumarolic exhalations related to hydrothermal-magmatic reservoirs in volcanic and geothermal areas and biogas released from waste landfills were compared: (a) Solid Traps (STs), consisting of three phase (Carboxen B, Carboxen C and Carbosieve S111) absorbent stainless steel tubes and (b) Solid Phase Micro Extraction (SPME) fibers, composed of DiVinylBenzene (DVB), Carboxen and PolyDimethylSiloxane. These techniques were applied to pre-concentrate VOCs discharged from: (i) low-to-high temperature fumaroles collected at Vulcano Island, Phlegrean Fields (Italy), and Nisyros Island (Greece), (ii) recovery wells in a solid waste disposal site located near Florence (Italy). A glass condensing system cooled with water was used to collect the dry fraction of the fumarolic gases, in order to allow more efficient VOC absorption avoiding any interference by water vapor and acidic gases, such as SO 2 , H 2 S, HF and HCl, typically present at relatively high concentrations in these fluids. Up to 37 organic species, in the range of 40–400 m/z, were determined by coupling gas chromatography to mass spectrometry (GC–MS). This study shows that the VOC compositions of fumaroles and biogas determined via SPME and ST are largely consistent and can be applied to the analysis of VOCs in gases released from different natural and anthropogenic environments. The SPME method is rapid and simple and more appropriate for volcanic and geothermal emissions, where VOCs are present at relatively high concentrations and prolonged gas sampling may be hazardous for the operator. The ST method, allowing the collection of large quantities of sample, is to be preferred to analyze the VOC composition of fluids from diffuse emissions and air, where these compounds are present at relatively low concentrations.

  2. 6th conference on Advances in Optoelectronics and Micro/nano-optics

    International Nuclear Information System (INIS)

    2017-01-01

    The 6th Conference on Advances in Optoelectronics and Micro/nano-optics (AOM 2017) Nanjing, China April 23 - 26, 2017 Conference Co-Chairs: Yiping Cui - Southeast University, China Xiaocong Yuan - Shenzhen University, China Shining Zhu - Nanjing University, China WELCOME Journal of physics: Conference Series is publishing a volume of conference proceedings that contains a selection of papers presented at the 6 th Conference on Advances in Optoelectronics and Micro/nano-optics (AOM 2017), which is an OSA topical meeting that started in 2009. AOM 2017, organized by The Optical Society of America, Southeast University, and Jiangsu Optical Society, was successfully held at Nanjing, China from April 23 th -26 th , 2017. It aims to bring together leading academic scientists, researchers and scholars to exchange and share their experience and research results on all aspects of optoelectronics and micro/nano-optics, and to discuss the practical challenges encountered and the solutions adopted. Located in Yangtze River Delta area and the center of east China, Nanjing is the capital of Jiangsu province and the second largest city in the east China region, turned out to be an ideal meeting place for domestic and overseas participants of this international conference. The conference program included plenary talks, invited talks, oral and poster contributions. From numerous submissions, 64 of the most promising and IOP-relevant contributions were included in this volume. The submissions present original ideas or results of general significance, supported by clear reasoning, compelling evidence relevant to the research. The authors state clearly the problems and the significance of their research to theory and practice. Being a successful conference, this event gathered more than 300 qualified and high-level researchers and experts, which created a good platform for worldwide researchers and engineers to enjoy the academic communication. Taking advantage of this opportunity, we

  3. Advanced neutron imaging methods with a potential to benefit from pulsed sources

    International Nuclear Information System (INIS)

    Strobl, M.; Kardjilov, N.; Hilger, A.; Penumadu, D.; Manke, I.

    2011-01-01

    During the last decade neutron imaging has seen significant improvements in instrumentation, detection and spatial resolution. Additionally, a variety of new applications and methods have been explored. As a consequence of an outstanding development nowadays various techniques of neutron imaging go far beyond a two- and three-dimensional mapping of the attenuation coefficients for a broad range of samples. Neutron imaging has become sensitive to neutron scattering in the small angle scattering range as well as with respect to Bragg scattering. Corresponding methods potentially provide spatially resolved and volumetric data revealing microstructural inhomogeneities, texture variations, crystalline phase distributions and even strains in bulk samples. Other techniques allow for the detection of refractive index distribution through phase sensitive measurements and the utilization of polarized neutrons enables radiographic and tomographic investigations of magnetic fields and properties as well as electrical currents within massive samples. All these advanced methods utilize or depend on wavelength dependent signals, and are hence suited to profit significantly from pulsed neutron sources as will be discussed.

  4. Advanced model for fast assessment of piezoelectric micro energy harvesters

    Directory of Open Access Journals (Sweden)

    Raffaele eArdito

    2016-04-01

    Full Text Available The purpose of this work is to present recent advances in modelling and design of piezoelectric energy harvesters, in the framework of Micro-Electro-Mechanical Systems (MEMS. More specifically, the case of inertial energy harvesting is considered, in the sense that the kinetic energy due to environmental vibration is transformed into electrical energy by means of piezoelectric transduction. The execution of numerical analyses is greatly important in order to predict the actual behaviour of MEMS devices and to carry out the optimization process. In the common practice, the results are obtained by means of burdensome 3D Finite Element Analyses (FEA.The case of beams could be treated by applying 1D models, which can enormously reduce the computational burden with obvious benefits in the case of repeated analyses. Unfortunately, the presence of piezoelectric coupling may entail some serious issues in view of its intrinsically three-dimensional behaviour. In this paper, a refined, yet simple, model is proposed with the objective of retaining the Euler-Bernoulli beam model, with the inclusion of effects connected to the actual three-dimensional shape of the device. The proposed model is adopted to evaluate the performances of realistic harvesters, both in the case of harmonic excitation and for impulsive loads.

  5. Efficiency of Micro-fine Cement Grouting in Liquefiable Sand

    International Nuclear Information System (INIS)

    Mirjalili, Mojtaba; Mirdamadi, Alireza; Ahmadi, Alireza

    2008-01-01

    In the presence of strong ground motion, liquefaction hazards are likely to occur in saturated cohesion-less soils. The risk of liquefaction and subsequent deformation can be reduced by various ground improvement methods including the cement grouting technique. The grouting method was proposed for non-disruptive mitigation of liquefaction risk at developed sites susceptible to liquefaction. In this research, a large-scale experiment was developed for assessment of micro-fine cement grouting effect on strength behavior and liquefaction potential of loose sand. Loose sand samples treated with micro-fine grout in multidirectional experimental model, were tested under cyclic and monotonic triaxial loading to investigate the influence of micro-fine grout on the deformation properties and pore pressure response. The behavior of pure sand was compared with the behavior of sand grouted with a micro-fine cement grout. The test results were shown that cement grouting with low concentrations significantly decreased the liquefaction potential of loose sand and related ground deformation

  6. Nondestructive chemical imaging of wood at the micro-scale: advanced technology to complement macro-scale evaluations

    Science.gov (United States)

    Barbara L. Illman; Julia Sedlmair; Miriam Unger; Carol Hirschmugl

    2013-01-01

    Chemical images help understanding of wood properties, durability, and cell wall deconstruction for conversion of lignocellulose to biofuels, nanocellulose and other value added chemicals in forest biorefineries. We describe here a new method for nondestructive chemical imaging of wood and wood-based materials at the micro-scale to complement macro-scale methods based...

  7. Use of technology as a competitive advantage in micro and small retail business in Hermosillo, Sonora

    Directory of Open Access Journals (Sweden)

    Carmen Bocanegra Gastelum

    2010-07-01

    Full Text Available The advance of new technologies of information and communication technologies (icts are not distributed evenly between companies in different sectors of the economy. These include not only the use of Internet and computer, but other tools related to the administrative operations of firms as well as knowledge of the profile of the consumer. This is especially true in enterprises of trade and services sector, where there is a significant gap between the micro, small, medium and large farms. Therefore, the study aims to examine whether the micro and small retailers in Hermosillo, Sonora, ict and know where, if applied as a competitive advantage. To achieve the goal we worked a representative sample of 450 establishments. The result obtained in February 2009, shows that despite advances in the use of these technological tools, knowledge and degree of applicability is still insufficient for micro and small businesses. Therefore, do not have the competitive edge that represents the use of ict to remain successful in the local market.

  8. Improved method of in vivo respiratory-gated micro-CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Walters, Erin B; Panda, Kunal; Bankson, James A; Brown, Ellana; Cody, Dianna D [Department of Imaging Physics, Unit 56, University of Texas M. D. Anderson Cancer Center, 1515 Holcombe Blvd., Houston, TX 77030 (United States)

    2004-09-07

    The presence of motion artifacts is a typical problem in thoracic imaging. However, synchronizing the respiratory cycle with computed tomography (CT) image acquisition can reduce these artifacts. We currently employ a method of in vivo respiratory-gated micro-CT imaging for small laboratory animals (mice). This procedure involves the use of a ventilator that controls the respiratory cycle of the animal and provides a digital output signal that is used to trigger data acquisition. After inspection of the default respiratory trigger timing, we hypothesized that image quality could be improved by moving the data-acquisition window to a portion of the cycle with less respiratory motion. For this reason, we developed a simple delay circuit to adjust the timing of the ventilator signal that initiates micro-CT data acquisition. This delay circuit decreases motion artifacts and substantially improves image quality.

  9. Improved method of in vivo respiratory-gated micro-CT imaging

    International Nuclear Information System (INIS)

    Walters, Erin B; Panda, Kunal; Bankson, James A; Brown, Ellana; Cody, Dianna D

    2004-01-01

    The presence of motion artifacts is a typical problem in thoracic imaging. However, synchronizing the respiratory cycle with computed tomography (CT) image acquisition can reduce these artifacts. We currently employ a method of in vivo respiratory-gated micro-CT imaging for small laboratory animals (mice). This procedure involves the use of a ventilator that controls the respiratory cycle of the animal and provides a digital output signal that is used to trigger data acquisition. After inspection of the default respiratory trigger timing, we hypothesized that image quality could be improved by moving the data-acquisition window to a portion of the cycle with less respiratory motion. For this reason, we developed a simple delay circuit to adjust the timing of the ventilator signal that initiates micro-CT data acquisition. This delay circuit decreases motion artifacts and substantially improves image quality

  10. Automatic method for estimation of in situ effective contact angle from X-ray micro tomography images of two-phase flow in porous media.

    Science.gov (United States)

    Scanziani, Alessio; Singh, Kamaljit; Blunt, Martin J; Guadagnini, Alberto

    2017-06-15

    Multiphase flow in porous media is strongly influenced by the wettability of the system, which affects the arrangement of the interfaces of different phases residing in the pores. We present a method for estimating the effective contact angle, which quantifies the wettability and controls the local capillary pressure within the complex pore space of natural rock samples, based on the physical constraint of constant curvature of the interface between two fluids. This algorithm is able to extract a large number of measurements from a single rock core, resulting in a characteristic distribution of effective in situ contact angle for the system, that is modelled as a truncated Gaussian probability density distribution. The method is first validated on synthetic images, where the exact angle is known analytically; then the results obtained from measurements within the pore space of rock samples imaged at a resolution of a few microns are compared to direct manual assessment. Finally the method is applied to X-ray micro computed tomography (micro-CT) scans of two Ketton cores after waterflooding, that display water-wet and mixed-wet behaviour. The resulting distribution of in situ contact angles is characterized in terms of a mixture of truncated Gaussian densities. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.

  11. Development of micro tensile testing method in an FIB system for evaluating grain boundary strength

    International Nuclear Information System (INIS)

    Fujii, Katsuhiko; Fukuya, Koji

    2010-01-01

    A micro tensile testing method for evaluating grain boundary strength was developed. Specimens of 2 x 2 x 10μm having one grain boundary were made by focused ion beam (FIB) micro-processing and tensioned in an FIB system in situ. The load was measured from the deflection of the silicon cantilever. The method was applied to aged and unaged Fe-Mn-P alloy specimens with different level of grain boundary phosphorus segregation. The load at intergranular fracture decreased with increasing phosphorus segregation. (author)

  12. MicroShield/ISOCS gamma modeling comparison.

    Energy Technology Data Exchange (ETDEWEB)

    Sansone, Kenneth R

    2013-08-01

    Quantitative radiological analysis attempts to determine the quantity of activity or concentration of specific radionuclide(s) in a sample. Based upon the certified standards that are used to calibrate gamma spectral detectors, geometric similarities between sample shape and the calibration standards determine if the analysis results developed are qualitative or quantitative. A sample analyzed that does not mimic a calibrated sample geometry must be reported as a non-standard geometry and thus the results are considered qualitative and not quantitative. MicroShieldR or ISOCSR calibration software can be used to model non-standard geometric sample shapes in an effort to obtain a quantitative analytical result. MicroShieldR and Canberras ISOCSR software contain several geometry templates that can provide accurate quantitative modeling for a variety of sample configurations. Included in the software are computational algorithms that are used to develop and calculate energy efficiency values for the modeled sample geometry which can then be used with conventional analysis methodology to calculate the result. The response of the analytical method and the sensitivity of the mechanical and electronic equipment to the radionuclide of interest must be calibrated, or standardized, using a calibrated radiological source that contains a known and certified amount of activity.

  13. Micro-seismic imaging using a source function independent full waveform inversion method

    KAUST Repository

    Wang, Hanchen; Alkhalifah, Tariq Ali

    2018-01-01

    hand, the conventional micro-seismic source locating methods require, in many cases manual picking of traveltime arrivals, which do not only lead to manual effort and human interaction, but also prone to errors. Using full waveform inversion (FWI

  14. Reliable and Accurate Release of Micro-Sized Objects with a Gripper that Uses the Capillary-Force Method

    Directory of Open Access Journals (Sweden)

    Suzana Uran

    2017-06-01

    Full Text Available There have been recent developments in grippers that are based on capillary force and condensed water droplets. These are used for manipulating micro-sized objects. Recently, one-finger grippers have been produced that are able to reliably grip using the capillary force. To release objects, either the van der Waals, gravitational or inertial-forces method is used. This article presents methods for reliably gripping and releasing micro-objects using the capillary force. The moisture from the surrounding air is condensed into a thin layer of water on the contact surfaces of the objects. From the thin layer of water, a water meniscus between the micro-sized object, the gripper and the releasing surface is created. Consequently, the water meniscus between the object and the releasing surface produces a high enough capillary force to release the micro-sized object from the tip of the one-finger gripper. In this case, either polystyrene, glass beads with diameters between 5–60 µm, or irregularly shaped dust particles of similar sizes were used. 3D structures made up of micro-sized objects could be constructed using this method. This method is reliable for releasing during assembly and also for gripping, when the objects are removed from the top of the 3D structure—the so-called “disassembling gripping” process. The accuracy of the release was lower than 0.5 µm.

  15. Towards the first generation micro bulk forming system

    DEFF Research Database (Denmark)

    Arentoft, Mogens; Eriksen, Rasmus Solmer; Hansen, Hans Nørgaard

    2011-01-01

    . This work describes a number of prototype system units, which collectively form a desktop sized micro forming production system. The system includes a billet preparation module, an integrated transfer system, a temperature controlled forming tool, including process simulation, and a dedicated micro forming......The industrial demand for micro mechanical components has surged in the later years with the constant introduction of more integrated products. The micro bulk forming process holds a promising pledge of delivering high quality micro mechanical components at low cost and high production rates...... press. The system is demonstrated on an advanced micro forming case where a dental component is formed in medical grade Titanium....

  16. Research on Laser Micro Polishing of SLS Technology Sintered Iron-Based Powder Surface

    Directory of Open Access Journals (Sweden)

    Gerda Vaitkūnaitė

    2015-03-01

    Full Text Available The article analyzes laser micro polishing of 1.2083 steel samples produced applying selective laser sintering (SLS method. The study has evaluated the distribution of the shape, size and temperature of the laser beam treated area in the surface layer of sintered and laser polished samples. Experimental tests have shown the impact of the technical parameters of laser micro polishing on the width and hardness of the impact zone of the treated sample. The microstructure analysis of laser treated and untreated areas of the material has been made.

  17. Study of 3D printing method for GRIN micro-optics devices

    Science.gov (United States)

    Wang, P. J.; Yeh, J. A.; Hsu, W. Y.; Cheng, Y. C.; Lee, W.; Wu, N. H.; Wu, C. Y.

    2016-03-01

    Conventional optical elements are based on either refractive or reflective optics theory to fulfill the design specifications via optics performance data. In refractive optical lenses, the refractive index of materials and radius of curvature of element surfaces determine the optical power and wavefront aberrations so that optical performance can be further optimized iteratively. Although gradient index (GRIN) phenomenon in optical materials is well studied for more than a half century, the optics theory in lens design via GRIN materials is still yet to be comprehensively investigated before realistic GRIN lenses are manufactured. In this paper, 3D printing method for manufacture of micro-optics devices with special features has been studied based on methods reported in the literatures. Due to the additive nature of the method, GRIN lenses in micro-optics devices seem to be readily achievable if a design methodology is available. First, derivation of ray-tracing formulae is introduced for all possible structures in GRIN lenses. Optics simulation program is employed for characterization of GRIN lenses with performance data given by aberration coefficients in Zernike polynomial. Finally, a proposed structure of 3D printing machine is described with conceptual illustration.

  18. Statistical hadronization and hadronic micro-canonical ensemble II

    International Nuclear Information System (INIS)

    Becattini, F.; Ferroni, L.

    2004-01-01

    We present a Monte Carlo calculation of the micro-canonical ensemble of the ideal hadron-resonance gas including all known states up to a mass of about 1.8 GeV and full quantum statistics. The micro-canonical average multiplicities of the various hadron species are found to converge to the canonical ones for moderately low values of the total energy, around 8 GeV, thus bearing out previous analyses of hadronic multiplicities in the canonical ensemble. The main numerical computing method is an importance sampling Monte Carlo algorithm using the product of Poisson distributions to generate multi-hadronic channels. It is shown that the use of this multi-Poisson distribution allows for an efficient and fast computation of averages, which can be further improved in the limit of very large clusters. We have also studied the fitness of a previously proposed computing method, based on the Metropolis Monte Carlo algorithm, for event generation in the statistical hadronization model. We find that the use of the multi-Poisson distribution as proposal matrix dramatically improves the computation performance. However, due to the correlation of subsequent samples, this method proves to be generally less robust and effective than the importance sampling method. (orig.)

  19. Let-7 microRNAs are developmentally regulated in circulating human erythroid cells

    Directory of Open Access Journals (Sweden)

    Reed Christopher

    2009-11-01

    Full Text Available Abstract Background MicroRNAs are ~22nt-long small non-coding RNAs that negatively regulate protein expression through mRNA degradation or translational repression in eukaryotic cells. Based upon their importance in regulating development and terminal differentiation in model systems, erythrocyte microRNA profiles were examined at birth and in adults to determine if changes in their abundance coincide with the developmental phenomenon of hemoglobin switching. Methods Expression profiling of microRNA was performed using total RNA from four adult peripheral blood samples compared to four cord blood samples after depletion of plasma, platelets, and nucleated cells. Labeled RNAs were hybridized to custom spotted arrays containing 474 human microRNA species (miRBase release 9.1. Total RNA from Epstein-Barr virus (EBV-transformed lymphoblastoid cell lines provided a hybridization reference for all samples to generate microRNA abundance profile for each sample. Results Among 206 detected miRNAs, 79% of the microRNAs were present at equivalent levels in both cord and adult cells. By comparison, 37 microRNAs were up-regulated and 4 microRNAs were down-regulated in adult erythroid cells (fold change > 2; p let-7 miRNA family consistently demonstrated increased abundance in the adult samples by array-based analyses that were confirmed by quantitative PCR (4.5 to 18.4 fold increases in 6 of 8 let-7 miRNA. Profiling studies of messenger RNA (mRNA in these cells additionally demonstrated down-regulation of ten let-7 target genes in the adult cells. Conclusion These data suggest that a consistent pattern of up-regulation among let-7 miRNA in circulating erythroid cells occurs in association with hemoglobin switching during the fetal-to-adult developmental transition in humans.

  20. Strategies to identify microRNA targets: New advances

    Science.gov (United States)

    MicroRNAs (miRNAs) are small regulatory RNA molecules functioning to modulate gene expression at the post-transcriptional level, and playing an important role in many developmental and physiological processes. Ten thousand miRNAs have been discovered in various organisms. Although considerable progr...

  1. Evaluation of Fine Aggregate Morphology by Image Method and Its Effect on Skid-Resistance of Micro-Surfacing

    Directory of Open Access Journals (Sweden)

    Yue Xiao

    2018-05-01

    Full Text Available Micro-surfacing is a widely used pavement preventive maintenance technology used all over the world, due to its advantages of fast construction, low maintenance cost, good waterproofness, and skid-resistance performance. This study evaluated the fine aggregate morphology and surface texture of micro-surfacing by AIMS (aggregate image measurement system, and explored the effect of aggregate morphology on skid-resistance of single-grade micro-surfacing. Sand patch test and British pendulum test were also used to detect skid-resistance for comparison with the image-based method. Wet abrasion test was used to measure skid-resistance durability for feasibility verification of single-grade micro-surfacing. The results show that the effect of Form2D on the skid-resistance of micro-surfacing is much stronger than that of angularity. Combining the feasibility analysis of durability and skid-resistance, 1.18–2.36 grade micro-surfacing meets the requirements of durability and skid-resistance at the same time. This study also determined that, compared with British pendulum test, the texture result obtained by sand patch test fits better with results of image method.

  2. A new method for the characterization of micro-/nano-periodic structures based on microscopic Moiré fringes

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Dan; Xie, Huimin, E-mail: xiehm@mail.tsinghua.edu.cn; Tang, Minjin; Hu, Zhenxing

    2014-01-15

    Linewidth and opening ratio (ratio of linewidth to period) are important parameters in characterizing micro-/nano-periodic and quasi-periodic structures. Periodic structures are conventionally characterized by the direct observation of specimens under a microscope. However, the field of view is relatively small, and only certain details can be acquired under a microscope. Moreover, the non-uniformity of the linewidth in quasi-periodic structures cannot be detected. This paper proposes a new characterization method for determining the linewidth and opening ratio of periodic structures based on Moiré fringe analysis. This method has the advantage of full-field characterization of the linewidth of micro-/nano-structures over a larger area than that afforded by direct observation. To validate the method, the linewidth of scanning electron microscope (SEM) scan lines was first calibrated with a standard grating. Next, a microperiodic structure with known geometry was characterized using this calibrated SEM system. The results indicate that the proposed method is simple and effective, indicating a potential approach for the characterization of gratings over large areas. This technique can be extended to various high-power scanning microscopes to characterize micro-/nano-structures. - Highlights: • A characterization method of the linewidth of high frequency gratings based on the microscope Moiré fringes is introduced. • The principle is according to the geometrical relationship between the gratings and the Moiré fringes. • This method has the potential application in characterization of the micro-/nano-structures. • The advantage of this method is that the micro-/nano-structures can be characterized in large view field under the full field of the microscope. • The microstructure of a butterfly has been characterized to declare the feasibility of this method.

  3. SWOT ANALYSIS ON SAMPLING METHOD

    Directory of Open Access Journals (Sweden)

    CHIS ANCA OANA

    2014-07-01

    Full Text Available Audit sampling involves the application of audit procedures to less than 100% of items within an account balance or class of transactions. Our article aims to study audit sampling in audit of financial statements. As an audit technique largely used, in both its statistical and nonstatistical form, the method is very important for auditors. It should be applied correctly for a fair view of financial statements, to satisfy the needs of all financial users. In order to be applied correctly the method must be understood by all its users and mainly by auditors. Otherwise the risk of not applying it correctly would cause loose of reputation and discredit, litigations and even prison. Since there is not a unitary practice and methodology for applying the technique, the risk of incorrectly applying it is pretty high. The SWOT analysis is a technique used that shows the advantages, disadvantages, threats and opportunities. We applied SWOT analysis in studying the sampling method, from the perspective of three players: the audit company, the audited entity and users of financial statements. The study shows that by applying the sampling method the audit company and the audited entity both save time, effort and money. The disadvantages of the method are difficulty in applying and understanding its insight. Being largely used as an audit method and being a factor of a correct audit opinion, the sampling method’s advantages, disadvantages, threats and opportunities must be understood by auditors.

  4. Sampling system and method

    Science.gov (United States)

    Decker, David L.; Lyles, Brad F.; Purcell, Richard G.; Hershey, Ronald Lee

    2013-04-16

    The present disclosure provides an apparatus and method for coupling conduit segments together. A first pump obtains a sample and transmits it through a first conduit to a reservoir accessible by a second pump. The second pump further conducts the sample from the reservoir through a second conduit.

  5. A method of language sampling

    DEFF Research Database (Denmark)

    Rijkhoff, Jan; Bakker, Dik; Hengeveld, Kees

    1993-01-01

    In recent years more attention is paid to the quality of language samples in typological work. Without an adequate sampling strategy, samples may suffer from various kinds of bias. In this article we propose a sampling method in which the genetic criterion is taken as the most important: samples...... to determine how many languages from each phylum should be selected, given any required sample size....

  6. Dispersive solid phase micro-extraction of mercury(II from environmental water and vegetable samples with ionic liquid modified graphene oxide nanoparticles

    Directory of Open Access Journals (Sweden)

    Nasrollahpour Atefeh

    2017-01-01

    Full Text Available A new dispersive solid phase micro-extraction (dispersive-SPME method for separation and preconcentration of mercury(II using ionic liquid modified magnetic reduced graphene oxide (IL-MrGO nanoparticles, prior to the measurement by cold vapour atomic absorption spectrometry (CV-AAS has been developed. The IL-MrGO composite was characterized by Brunauer– Emmett–Teller method (BET for adsorption-desorption measurement, thermogravimetric analysis (TGA, powder X-ray diffraction (XRD and X-ray photoelectron spectroscopy (XPS. The method is based on the sorption of mercury( II on IL-MrGO nanoparticles due to electrostatic interaction and complex formation of ionic liquid part of IL-MrGO with mercury(II. The effect of experimental parameters for preconcentration of mercury(II, such as solution type, concentration and volume of the eluent, pH, time of the sorption and desorption, amount of the sorbent and coexisting ion concentration have been optimized. Under the optimized conditions, a linear response was obtained in the concentration range of 0.08–10 ng mL-1 with a determination coefficient of 0.9995. The limit of detection (LOD of the method at a signal to noise ratio of 3 was 0.01 ng mL-1. Intra-day and inter-day precisions were obtained equal to 3.4 and 4.5 %, respectively. The dispersive solid phase micro-extraction of mercury(II on IL-MrGO nanoparticles coupled with cold vapour atomic absorption spectrometry was successfully used for extraction and determination of mercury(II in water and vegetable samples.

  7. Identifying mRNA targets of microRNA dysregulated in cancer: with application to clear cell Renal Cell Carcinoma

    Directory of Open Access Journals (Sweden)

    Liou Louis S

    2010-04-01

    Full Text Available Abstract Background MicroRNA regulate mRNA levels in a tissue specific way, either by inducing degradation of the transcript or by inhibiting translation or transcription. Putative mRNA targets of microRNA identified from seed sequence matches are available in many databases. However, such matches have a high false positive rate and cannot identify tissue specificity of regulation. Results We describe a simple method to identify direct mRNA targets of microRNA dysregulated in cancers from expression level measurements in patient matched tumor/normal samples. The word "direct" is used here in a strict sense to: a represent mRNA which have an exact seed sequence match to the microRNA in their 3'UTR, b the seed sequence match is strictly conserved across mouse, human, rat and dog genomes, c the mRNA and microRNA expression levels can distinguish tumor from normal with high significance and d the microRNA/mRNA expression levels are strongly and significantly anti-correlated in tumor and/or normal samples. We apply and validate the method using clear cell Renal Cell Carcinoma (ccRCC and matched normal kidney samples, limiting our analysis to mRNA targets which undergo degradation of the mRNA transcript because of a perfect seed sequence match. Dysregulated microRNA and mRNA are first identified by comparing their expression levels in tumor vs normal samples. Putative dysregulated microRNA/mRNA pairs are identified from these using seed sequence matches, requiring that the seed sequence be conserved in human/dog/rat/mouse genomes. These are further pruned by requiring a strong anti-correlation signature in tumor and/or normal samples. The method revealed many new regulations in ccRCC. For instance, loss of miR-149, miR-200c and mir-141 causes gain of function of oncogenes (KCNMA1, LOX, VEGFA and SEMA6A respectively and increased levels of miR-142-3p, miR-185, mir-34a, miR-224, miR-21 cause loss of function of tumor suppressors LRRC2, PTPN13, SFRP1

  8. Advanced methods of solid oxide fuel cell modeling

    CERN Document Server

    Milewski, Jaroslaw; Santarelli, Massimo; Leone, Pierluigi

    2011-01-01

    Fuel cells are widely regarded as the future of the power and transportation industries. Intensive research in this area now requires new methods of fuel cell operation modeling and cell design. Typical mathematical models are based on the physical process description of fuel cells and require a detailed knowledge of the microscopic properties that govern both chemical and electrochemical reactions. ""Advanced Methods of Solid Oxide Fuel Cell Modeling"" proposes the alternative methodology of generalized artificial neural networks (ANN) solid oxide fuel cell (SOFC) modeling. ""Advanced Methods

  9. Advanced computational electromagnetic methods and applications

    CERN Document Server

    Li, Wenxing; Elsherbeni, Atef; Rahmat-Samii, Yahya

    2015-01-01

    This new resource covers the latest developments in computational electromagnetic methods, with emphasis on cutting-edge applications. This book is designed to extend existing literature to the latest development in computational electromagnetic methods, which are of interest to readers in both academic and industrial areas. The topics include advanced techniques in MoM, FEM and FDTD, spectral domain method, GPU and Phi hardware acceleration, metamaterials, frequency and time domain integral equations, and statistics methods in bio-electromagnetics.

  10. Experimental investigation of the tip based micro/nano machining

    Science.gov (United States)

    Guo, Z.; Tian, Y.; Liu, X.; Wang, F.; Zhou, C.; Zhang, D.

    2017-12-01

    Based on the self-developed three dimensional micro/nano machining system, the effects of machining parameters and sample material on micro/nano machining are investigated. The micro/nano machining system is mainly composed of the probe system and micro/nano positioning stage. The former is applied to control the normal load and the latter is utilized to realize high precision motion in the xy plane. A sample examination method is firstly introduced to estimate whether the sample is placed horizontally. The machining parameters include scratching direction, speed, cycles, normal load and feed. According to the experimental results, the scratching depth is significantly affected by the normal load in all four defined scratching directions but is rarely influenced by the scratching speed. The increase of scratching cycle number can increase the scratching depth as well as smooth the groove wall. In addition, the scratching tests of silicon and copper attest that the harder material is easier to be removed. In the scratching with different feed amount, the machining results indicate that the machined depth increases as the feed reduces. Further, a cubic polynomial is used to fit the experimental results to predict the scratching depth. With the selected machining parameters of scratching direction d3/d4, scratching speed 5 μm/s and feed 0.06 μm, some more micro structures including stair, sinusoidal groove, Chinese character '田', 'TJU' and Chinese panda have been fabricated on the silicon substrate.

  11. Value of micro-CT as an Investigative Tool for Osteochondritis Dissecans. A preliminary study with comparison to histology

    International Nuclear Information System (INIS)

    Mohr, A.; Bergmann, I.; Muhle, C.; Heller, M.; Heiss, C.; Schrader, C.; Roemer, F.W.; Lynch, J.A.; Genant, H.K.

    2003-01-01

    Purpose: To evaluate micro computed tomography (micro-CT) for the assessment of osteochondritis dissecans in comparison with histology. Material and Methods: Osteochondritis dissecans lesions of 3 patients were evaluated using micro-CT (0.125 mA, 40 keV, 60 m slice thickness, 60 m isotropic resolution, entire sample) and light microscopy (toluidine blue, 3-5 m slice thickness). The methods were compared regarding preparation time, detectability of tissue types and morphologic features of bone and cartilage. Results: Non-destructive micro-CT imaging of the entire sample was faster than histologic preparation of a single slice for light microscopy. Morphologic features of bone and cartilage could be imaged in a comparable way to histology. It was not possible to image cells or different tissue types of bone and cartilage with micro-CT. Conclusion: Micro-CT is a fast, non-destructive tool that may be a supplement or, if detailed histologic information is not necessary, an alternative to light microscopy for the investigation of osteochondritis dissecans. Osteochondritis dissecans micro-CT histology comparative investigation

  12. Development of new assembly techniques for a silicon micro-vertex detector unit using the flip-chip bonding method

    International Nuclear Information System (INIS)

    Saitoh, Y.; Takeuchi, H.; Mandai, M.; Kanazawa, H.; Yamanaka, J.; Miyahara, S.; Kamiya, M.; Fujita, Y.; Higashi, Y.; Ikeda, H.; Ikeda, M.; Koike, S.; Matsuda, T.; Ozaki, H.; Tanaka, M.; Tsuboyama, T.; Avrillon, S.; Okuno, S.; Haba, J.; Hanai, H.; Mori, S.; Yusa, K.; Fukunaga, C.

    1994-01-01

    Full-size models of a detector unit for a silicon micro-vertex detector were built for the KEK B factory. The Flip-Chip Bonding (FCB) method using a new type anisotropic conductive film was examined. The structure using the FCB method successfully provides a new architecture for the silicon micro-vertex detector unit. (orig.)

  13. Functional efficiency comparison between split- and parallel-hybrid using advanced energy flow analysis methods

    Energy Technology Data Exchange (ETDEWEB)

    Guttenberg, Philipp; Lin, Mengyan [Romax Technology, Nottingham (United Kingdom)

    2009-07-01

    The following paper presents a comparative efficiency analysis of the Toyota Prius versus the Honda Insight using advanced Energy Flow Analysis methods. The sample study shows that even very different hybrid concepts like a split- and a parallel-hybrid can be compared in a high level of detail and demonstrates the benefit showing exemplary results. (orig.)

  14. Oral pathology follow-up by means of micro-Raman spectroscopy on tissue and blood serum samples: an application of wavelet and multivariate data analysis

    Science.gov (United States)

    Delfino, I.; Camerlingo, C.; Zenone, F.; Perna, G.; Capozzi, V.; Cirillo, N.; Gaeta, G. M.; De Mol, E.; Lepore, M.

    2009-02-01

    Pemphigus vulgaris (PV) is a potentially fatal autoimmune disease that cause blistering of the skin and oral cavity. It is characterized by disruption of cell-cell adhesion within the suprabasal layers of epithelium, a phenomenon termed acantholysis Patients with PV develop IgG autoantibodies against normal constituents of the intercellular substance of keratinocytes. The mechanisms by which such autoantibodies induce blisters are not clearly understood. The qualitative analysis of such effects provides important clues in the search for a specific diagnosis, and the quantitative analysis of biochemical abnormalities is important in measuring the extent of the disease process, designing therapy and evaluating the efficacy of treatment. Improved diagnostic techniques could permit the recognition of more subtle forms of disease and reveal incipient lesions clinically unapparent, so that progression of potentially severe forms could be reversed with appropriate treatment. In this paper, we report the results of our micro-Raman spectroscopy study on tissue and blood serum samples from ill, recovered and under therapy PV patients. The complexity of the differences among their characteristic Raman spectra has required a specific strategy to obtain reliable information on the illness stage of the patients For this purpose, wavelet techniques and advanced multivariate analysis methods have been developed and applied to the experimental Raman spectra. Promising results have been obtained.

  15. A Wrapping Method for Inserting Titanium Micro-Mesh Implants in the Reconstruction of Blowout Fractures

    Directory of Open Access Journals (Sweden)

    Tae Joon Choi

    2016-01-01

    Full Text Available Titanium micro-mesh implants are widely used in orbital wall reconstructions because they have several advantageous characteristics. However, the rough and irregular marginal spurs of the cut edges of the titanium mesh sheet impede the efficacious and minimally traumatic insertion of the implant, because these spurs may catch or hook the orbital soft tissue, skin, or conjunctiva during the insertion procedure. In order to prevent this problem, we developed an easy method of inserting a titanium micro-mesh, in which it is wrapped with the aseptic transparent plastic film that is used to pack surgical instruments or is attached to one side of the inner suture package. Fifty-four patients underwent orbital wall reconstruction using a transconjunctival or transcutaneous approach. The wrapped implant was easily inserted without catching or injuring the orbital soft tissue, skin, or conjunctiva. In most cases, the implant was inserted in one attempt. Postoperative computed tomographic scans showed excellent placement of the titanium micro-mesh and adequate anatomic reconstruction of the orbital walls. This wrapping insertion method may be useful for making the insertion of titanium micro-mesh implants in the reconstruction of orbital wall fractures easier and less traumatic.

  16. Current advances and strategies towards fully automated sample preparation for regulated LC-MS/MS bioanalysis.

    Science.gov (United States)

    Zheng, Naiyu; Jiang, Hao; Zeng, Jianing

    2014-09-01

    Robotic liquid handlers (RLHs) have been widely used in automated sample preparation for liquid chromatography-tandem mass spectrometry (LC-MS/MS) bioanalysis. Automated sample preparation for regulated bioanalysis offers significantly higher assay efficiency, better data quality and potential bioanalytical cost-savings. For RLHs that are used for regulated bioanalysis, there are additional requirements, including 21 CFR Part 11 compliance, software validation, system qualification, calibration verification and proper maintenance. This article reviews recent advances in automated sample preparation for regulated bioanalysis in the last 5 years. Specifically, it covers the following aspects: regulated bioanalysis requirements, recent advances in automation hardware and software development, sample extraction workflow simplification, strategies towards fully automated sample extraction, and best practices in automated sample preparation for regulated bioanalysis.

  17. Liquid Phase Micro-Extraction of Linear Alkylbenzene Sulfonate Anionic Surfactants in Aqueous Samples

    Directory of Open Access Journals (Sweden)

    Jan Åke Jönsson

    2011-10-01

    Full Text Available Hollow fiber liquid phase micro-extraction (LPME of linear alkylbenzene sulfonates (LAS from aqueous samples was studied. Ion pair extraction of C10, C11, C12 and C13 homologues was facilitated with trihexylamine as ion-pairing agent, using di-n-hexylether as solvent for the supported liquid membrane (SLM. Effects of extraction time, acceptor buffer concentration, stirring speed, sample volume, NaCl and humic acids were studied. At 10–50 µg L−1 linear R2-coefficients were 0.99 for C10 and C11 and 0.96 for C12. RSD was typically ~15%. Three observations were especially made. Firstly, LPME for these analytes was unusually slow with maximum enrichment observed after 15–24 h (depending on sample volume. Secondly, the enrichment depended on LAS sample concentration with 35–150 times enrichment below ~150 µg L−1 and 1850–4400 times enrichment at 1 mg L−1. Thirdly, lower homologues were enriched more than higher homologues at low sample concentrations, with reversed conditions at higher concentrations. These observations may be due to the fact that LAS and the amine counter ion themselves influence the mass transfer at the water-SLM interface. The observations on LPME of LAS may aid in LPME application to other compounds with surfactant properties or in surfactant enhanced membrane extraction of other compounds.

  18. Processing of micro-nano bacterial cellulose with hydrolysis method as a reinforcing bioplastic

    Science.gov (United States)

    Maryam, Maryam; Dedy, Rahmad; Yunizurwan, Yunizurwan

    2017-01-01

    Nanotechnology is the ability to create and manipulate atoms and molecules on the smallest of scales. Their size allows them to exhibit novel and significantly improved physical, chemical, biological properties, phenomena, and processes because of their size. The purpose of this research is obtaining micro-nano bacterial cellulose as reinforcing bioplastics. Bacterial cellulose (BC) was made from coconut water for two weeks. BC was dried and grinded. Bacterial cellulose was given purification process with NaOH 5% for 6 hours. Making the micro-nano bacterial cellulose with hydrolysis method. Hydrolysis process with hydrochloric acid (HCl) at the conditions 3,5M, 55°C, 6 hours. Drying process used spray dryer. The hydrolysis process was obtained bacterial cellulose with ±7 μm. The addition 2% micro-nano bacterial cellulose as reinforcing in bioplastics composite can improve the physical characteristics.

  19. Processing of micro-nano bacterial cellulose with hydrolysis method as a reinforcing bioplastic

    International Nuclear Information System (INIS)

    Maryam, Maryam; Yunizurwan, Yunizurwan; Dedy, Rahmad

    2017-01-01

    Nanotechnology is the ability to create and manipulate atoms and molecules on the smallest of scales. Their size allows them to exhibit novel and significantly improved physical, chemical, biological properties, phenomena, and processes because of their size. The purpose of this research is obtaining micro-nano bacterial cellulose as reinforcing bioplastics. Bacterial cellulose (BC) was made from coconut water for two weeks. BC was dried and grinded. Bacterial cellulose was given purification process with NaOH 5% for 6 hours. Making the micro-nano bacterial cellulose with hydrolysis method. Hydrolysis process with hydrochloric acid (HCl) at the conditions 3,5M, 55°C, 6 hours. Drying process used spray dryer. The hydrolysis process was obtained bacterial cellulose with ±7 μm. The addition 2% micro-nano bacterial cellulose as reinforcing in bioplastics composite can improve the physical characteristics. (paper)

  20. Micro-CT image reconstruction based on alternating direction augmented Lagrangian method and total variation.

    Science.gov (United States)

    Gopi, Varun P; Palanisamy, P; Wahid, Khan A; Babyn, Paul; Cooper, David

    2013-01-01

    Micro-computed tomography (micro-CT) plays an important role in pre-clinical imaging. The radiation from micro-CT can result in excess radiation exposure to the specimen under test, hence the reduction of radiation from micro-CT is essential. The proposed research focused on analyzing and testing an alternating direction augmented Lagrangian (ADAL) algorithm to recover images from random projections using total variation (TV) regularization. The use of TV regularization in compressed sensing problems makes the recovered image quality sharper by preserving the edges or boundaries more accurately. In this work TV regularization problem is addressed by ADAL which is a variant of the classic augmented Lagrangian method for structured optimization. The per-iteration computational complexity of the algorithm is two fast Fourier transforms, two matrix vector multiplications and a linear time shrinkage operation. Comparison of experimental results indicate that the proposed algorithm is stable, efficient and competitive with the existing algorithms for solving TV regularization problems. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. A robust rotation-invariance displacement measurement method for a micro-/nano-positioning system

    Science.gov (United States)

    Zhang, Xiang; Zhang, Xianmin; Wu, Heng; Li, Hai; Gan, Jinqiang

    2018-05-01

    A robust and high-precision displacement measurement method for a compliant mechanism-based micro-/nano-positioning system is proposed. The method is composed of an integer-pixel and a sub-pixel matching procedure. In the proposed algorithm (Pro-A), an improved ring projection transform (IRPT) and gradient information are used as features for approximating the coarse candidates and fine locations, respectively. Simulations are conducted and the results show that the Pro-A has the ability of rotation-invariance and strong robustness, with a theoretical accuracy of 0.01 pixel. To validate the practical performance, a series of experiments are carried out using a computer micro-vision and laser interferometer system (LIMS). The results demonstrate that both the LIMS and Pro-A can achieve high precision, while the Pro-A has better stability and adaptability.

  2. Subrandom methods for multidimensional nonuniform sampling.

    Science.gov (United States)

    Worley, Bradley

    2016-08-01

    Methods of nonuniform sampling that utilize pseudorandom number sequences to select points from a weighted Nyquist grid are commonplace in biomolecular NMR studies, due to the beneficial incoherence introduced by pseudorandom sampling. However, these methods require the specification of a non-arbitrary seed number in order to initialize a pseudorandom number generator. Because the performance of pseudorandom sampling schedules can substantially vary based on seed number, this can complicate the task of routine data collection. Approaches such as jittered sampling and stochastic gap sampling are effective at reducing random seed dependence of nonuniform sampling schedules, but still require the specification of a seed number. This work formalizes the use of subrandom number sequences in nonuniform sampling as a means of seed-independent sampling, and compares the performance of three subrandom methods to their pseudorandom counterparts using commonly applied schedule performance metrics. Reconstruction results using experimental datasets are also provided to validate claims made using these performance metrics. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Sterilization of microorganisms by the supercritical carbon dioxide micro-bubble method.

    Science.gov (United States)

    Ishikawa, H; Shimoda, M; Shiratsuchi, H; Osajima, Y

    1995-10-01

    Lactobacillus brevis and Saccharomyces cerevisiae were completely sterilized by the supercritical (SC) CO2 micro-bubble method. Gaseous (G) and liquid (LQ) CO2 were used in a similar manner to compare the sterilizing effect. Among the three treatments, the microorganisms were only effectively sterilized by the SC CO2 treatment at 25 MPa and 35 degrees C.

  4. Micro versus macro solid phase extraction for monitoring water contaminants: a preliminary study using trihalomethanes.

    Science.gov (United States)

    Alexandrou, Lydon D; Spencer, Michelle J S; Morrison, Paul D; Meehan, Barry J; Jones, Oliver A H

    2015-04-15

    Solid phase extraction is one of the most commonly used pre-concentration and cleanup steps in environmental science. However, traditional methods need electrically powered pumps, can use large volumes of solvent (if multiple samples are run), and require several hours to filter a sample. Additionally, if the cartridge is open to the air volatile compounds may be lost and sample integrity compromised. In contrast, micro cartridge based solid phase extraction can be completed in less than 2 min by hand, uses only microlitres of solvent and provides comparable concentration factors to established methods. It is also an enclosed system so volatile components are not lost. The sample can also be eluted directly into a detector (e.g. a mass spectrometer) if required. However, the technology is new and has not been much used for environmental analysis. In this study we compare traditional (macro) and the new micro solid phase extraction for the analysis of four common volatile trihalomethanes (trichloromethane, bromodichloromethane, dibromochloromethane and tribromomethane). The results demonstrate that micro solid phase extraction is faster and cheaper than traditional methods with similar recovery rates for the target compounds. This method shows potential for further development in a range of applications. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Passive sampling as a tool for identifying micro-organic compounds in groundwater.

    Science.gov (United States)

    Mali, N; Cerar, S; Koroša, A; Auersperger, P

    2017-09-01

    The paper presents the use of a simple and cost efficient passive sampling device with integrated active carbon with which to test the possibility of determining the presence of micro-organic compounds (MOs) in groundwater and identifying the potential source of pollution as well as the seasonal variability of contamination. Advantage of the passive sampler is to cover a long sampling period by integrating the pollutant concentration over time, and the consequently analytical costs over the monitoring period can be reduced substantially. Passive samplers were installed in 15 boreholes in the Maribor City area in Slovenia, with two sampling campaigns covered a period about one year. At all sampling sites in the first series a total of 103 compounds were detected, and 144 in the second series. Of all detected compounds the 53 most frequently detected were selected for further analysis. These were classified into eight groups based on the type of their source: Pesticides, Halogenated solvents, Non-halogenated solvents, Domestic and personal, Plasticizers and additives, Other industrial, Sterols and Natural compounds. The most frequently detected MO compounds in groundwater were tetrachloroethene and trichloroethene from the Halogenated solvents group. The most frequently detected among the compound's groups were pesticides. Analysis of frequency also showed significant differences between the two sampling series, with less frequent detections in the summer series. For the analysis to determine the origin of contamination three groups of compounds were determined according to type of use: agriculture, urban and industry. Frequency of detection indicates mixed land use in the recharge areas of sampling sites, which makes it difficult to specify the dominant origin of the compound. Passive sampling has proved to be useful tool with which to identify MOs in groundwater and for assessing groundwater quality. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Advances in imaging: impact on studying craniofacial bone structure.

    Science.gov (United States)

    Majumdar, S

    2003-01-01

    Methods for measuring the structure of craniofacial bones are discussed in this paper. In addition to the three-dimensional macro-structure of the craniofacial skeleton, there is considerable interest in imaging the bone at a microscopic resolution in order to depict the micro-architecture of the trabecular bone itself. In addition to the density of the bone, the microarchitecture reflects bone quality. An understanding of bone quality and density changes has implications for a number of craniofacial pathologies, as well as for implant design and understanding the biomechanical function and loading of the jaw. Trabecular bone micro-architecture has been recently imaged using imaging methods such as micro-computed tomography, magnetic resonance imaging, and the images have been used in finite element models to assess bone mechanical properties. In this paper, some of the recent advances in micro-computed tomography and magnetic resonance imaging are reviewed, and their potential for imaging the trabecular bone in mandibular bones is presented. Examples of in vitro and in vivo images are presented.

  7. Use of non-standardised micro-destructive techniques in the characterization of traditional construction materials

    Science.gov (United States)

    Ioannou, Ioannis; Theodoridou, Magdalini; Modestou, Sevasti; Fournari, Revecca; Dagrain, Fabrice

    2013-04-01

    The characterization of material properties and the diagnosis of their state of weathering and conservation are three of the most important steps in the field of cultural heritage preservation. Several standardised experimental methods exist, especially for determining the material properties and their durability. However, they are limited in their application by the required size of test specimens and the controlled laboratory conditions needed to undertake the tests; this is especially true when the materials under study constitute immovable parts of heritage structures. The current use of other advanced methods of analysis, such as imaging techniques, in the aforementioned field of research offers invaluable results. However, these techniques may not always be accessible to the wider research community due to their complex nature and relatively high cost of application. This study presents innovative applications of two recently developed cutting techniques; the portable Drilling Resistance Measuring System (DRMS) and the scratch tool. Both methods are defined as micro-destructive, since they only destroy a very small portion of sample material. The general concept of both methods lies within the forces needed to cut a material by linear (scratch tool) or rotational (DRMS) cutting action; these forces are related to the mechanical properties of the material and the technological parameters applied on the tool. Therefore, for a given testing configuration, the only parameter influencing the forces applied is the strength of the material. These two techniques have been used alongside a series of standardised laboratory tests aiming at the correlation of various stone properties (density, porosity, dynamic elastic modulus and uniaxial compressive strength). The results prove the potential of both techniques in assessing the uniaxial compressive strength of stones. The scratch tool has also been used effectively to estimate the compressive strength of mud bricks. It

  8. Some connections between importance sampling and enhanced sampling methods in molecular dynamics.

    Science.gov (United States)

    Lie, H C; Quer, J

    2017-11-21

    In molecular dynamics, enhanced sampling methods enable the collection of better statistics of rare events from a reference or target distribution. We show that a large class of these methods is based on the idea of importance sampling from mathematical statistics. We illustrate this connection by comparing the Hartmann-Schütte method for rare event simulation (J. Stat. Mech. Theor. Exp. 2012, P11004) and the Valsson-Parrinello method of variationally enhanced sampling [Phys. Rev. Lett. 113, 090601 (2014)]. We use this connection in order to discuss how recent results from the Monte Carlo methods literature can guide the development of enhanced sampling methods.

  9. Laser based micro forming and assembly.

    Energy Technology Data Exchange (ETDEWEB)

    MacCallum, Danny O' Neill; Wong, Chung-Nin Channy; Knorovsky, Gerald Albert; Steyskal, Michele D.; Lehecka, Tom (Pennsylvania State University, Freeport, PA); Scherzinger, William Mark; Palmer, Jeremy Andrew

    2006-11-01

    It has been shown that thermal energy imparted to a metallic substrate by laser heating induces a transient temperature gradient through the thickness of the sample. In favorable conditions of laser fluence and absorptivity, the resulting inhomogeneous thermal strain leads to a measurable permanent deflection. This project established parameters for laser micro forming of thin materials that are relevant to MESA generation weapon system components and confirmed methods for producing micrometer displacements with repeatable bend direction and magnitude. Precise micro forming vectors were realized through computational finite element analysis (FEA) of laser-induced transient heating that indicated the optimal combination of laser heat input relative to the material being heated and its thermal mass. Precise laser micro forming was demonstrated in two practical manufacturing operations of importance to the DOE complex: micrometer gap adjustments of precious metal alloy contacts and forming of meso scale cones.

  10. Isothermal circular-strand-displacement polymerization of DNA and microRNA in digital microfluidic devices.

    Science.gov (United States)

    Giuffrida, Maria Chiara; Zanoli, Laura Maria; D'Agata, Roberta; Finotti, Alessia; Gambari, Roberto; Spoto, Giuseppe

    2015-02-01

    Nucleic-acid amplification is a crucial step in nucleic-acid-sequence-detection assays. The use of digital microfluidic devices to miniaturize amplification techniques reduces the required sample volume and the analysis time and offers new possibilities for process automation and integration in a single device. The recently introduced droplet polymerase-chain-reaction (PCR) amplification methods require repeated cycles of two or three temperature-dependent steps during the amplification of the nucleic-acid target sequence. In contrast, low-temperature isothermal-amplification methods have no need for thermal cycling, thus requiring simplified microfluidic-device features. Here, the combined use of digital microfluidics and molecular-beacon (MB)-assisted isothermal circular-strand-displacement polymerization (ICSDP) to detect microRNA-210 sequences is described. MicroRNA-210 has been described as the most consistently and predominantly upregulated hypoxia-inducible factor. The nmol L(-1)-pmol L(-1) detection capabilities of the method were first tested by targeting single-stranded DNA sequences from the genetically modified Roundup Ready soybean. The ability of the droplet-ICSDP method to discriminate between full-matched, single-mismatched, and unrelated sequences was also investigated. The detection of a range of nmol L(-1)-pmol L(-1) microRNA-210 solutions compartmentalized in nanoliter-sized droplets was performed, establishing the ability of the method to detect as little as 10(-18) mol of microRNA target sequences compartmentalized in 20 nL droplets. The suitability of the method for biological samples was tested by detecting microRNA-210 from transfected K562 cells.

  11. Tunable micro-optics

    CERN Document Server

    Duppé, Claudia

    2015-01-01

    Presenting state-of-the-art research into the dynamic field of tunable micro-optics, this is the first book to provide a comprehensive survey covering a varied range of topics including novel materials, actuation concepts and new imaging systems in optics. Internationally renowned researchers present a diverse range of chapters on cutting-edge materials, devices and subsystems, including soft matter, artificial muscles, tunable lenses and apertures, photonic crystals, and complete tunable imagers. Special contributions also provide in-depth treatment of micro-optical characterisation, scanners, and the use of natural eye models as inspiration for new concepts in advanced optics. With applications extending from medical diagnosis to fibre telecommunications, Tunable Micro-optics equips readers with a solid understanding of the broader technical context through its interdisciplinary approach to the realisation of new types of optical systems. This is an essential resource for engineers in industry and academia,...

  12. Best practice strategies for validation of micro moulding process simulation

    DEFF Research Database (Denmark)

    Costa, Franco; Tosello, Guido; Whiteside, Ben

    2009-01-01

    are the optimization of the moulding process and of the tool using simulation techniques. Therefore, in polymer micro manufacturing technology, software simulation tools adapted from conventional injection moulding can provide useful assistance for the optimization of moulding tools, mould inserts, micro component...... are discussed. Recommendations regarding sampling rate, meshing quality, filling analysis methods (micro short shots, flow visualization) and machine geometry modelling are given on the basis of the comparison between simulated and experimental results within the two considered study cases.......Simulation programs in polymer micro replication technology are used for the same reasons as in conventional injection moulding. To avoid the risks of costly re-engineering, the moulding process is simulated before starting the actual manufacturing process. Important economic factors...

  13. Perpendicular distance sampling: an alternative method for sampling downed coarse woody debris

    Science.gov (United States)

    Michael S. Williams; Jeffrey H. Gove

    2003-01-01

    Coarse woody debris (CWD) plays an important role in many forest ecosystem processes. In recent years, a number of new methods have been proposed to sample CWD. These methods select individual logs into the sample using some form of unequal probability sampling. One concern with most of these methods is the difficulty in estimating the volume of each log. A new method...

  14. The influence of selected design and operating parameters on the dynamics of the steam micro-turbine

    Science.gov (United States)

    Żywica, Grzegorz; Kiciński, Jan

    2015-10-01

    The topic of the article is the analysis of the influence of selected design parameters and operating conditions on the radial steam micro-turbine, which was adapted to operate with low-boiling agent in the Organic Rankine Cycle (ORC). In the following parts of this article the results of the thermal load analysis, the residual unbalance and the stiffness of bearing supports are discussed. Advanced computational methods and numerical models have been used. Computational analysis showed that the steam micro-turbine is characterized by very good dynamic properties and is resistant to extreme operating conditions. The prototype of micro-turbine has passed a series of test calculations. It has been found that it can be subjected to experimental research in the micro combined heat and power system.

  15. Sampling method of environmental radioactivity monitoring

    International Nuclear Information System (INIS)

    1984-01-01

    This manual provides sampling methods of environmental samples of airborne dust, precipitated dust, precipitated water (rain or snow), fresh water, soil, river sediment or lake sediment, discharged water from a nuclear facility, grains, tea, milk, pasture grass, limnetic organisms, daily diet, index organisms, sea water, marine sediment, marine organisms, and that for tritium and radioiodine determination for radiation monitoring from radioactive fallout or radioactivity release by nuclear facilities. This manual aims at the presentation of standard sampling procedures for environmental radioactivity monitoring regardless of monitoring objectives, and shows preservation method of environmental samples acquired at the samplingpoint for radiation counting for those except human body. Sampling techniques adopted in this manual is decided by the criteria that they are suitable for routine monitoring and any special skillfulness is not necessary. Based on the above-mentioned principle, this manual presents outline and aims of sampling, sampling position or object, sampling quantity, apparatus, equipment or vessel for sampling, sampling location, sampling procedures, pretreatment and preparation procedures of a sample for radiation counting, necessary recording items for sampling and sample transportation procedures. Special attention is described in the chapter of tritium and radioiodine because these radionuclides might be lost by the above-mentioned sample preservation method for radiation counting of less volatile radionuclides than tritium or radioiodine. (Takagi, S.)

  16. A novel mean-centering method for normalizing microRNA expression from high-throughput RT-qPCR data

    Directory of Open Access Journals (Sweden)

    Wylie Dennis

    2011-12-01

    Full Text Available Abstract Background Normalization is critical for accurate gene expression analysis. A significant challenge in the quantitation of gene expression from biofluids samples is the inability to quantify RNA concentration prior to analysis, underscoring the need for robust normalization tools for this sample type. In this investigation, we evaluated various methods of normalization to determine the optimal approach for quantifying microRNA (miRNA expression from biofluids and tissue samples when using the TaqMan® Megaplex™ high-throughput RT-qPCR platform with low RNA inputs. Findings We compared seven normalization methods in the analysis of variation of miRNA expression from biofluid and tissue samples. We developed a novel variant of the common mean-centering normalization strategy, herein referred to as mean-centering restricted (MCR normalization, which is adapted to the TaqMan Megaplex RT-qPCR platform, but is likely applicable to other high-throughput RT-qPCR-based platforms. Our results indicate that MCR normalization performs comparable to or better than both standard mean-centering and other normalization methods. We also propose an extension of this method to be used when migrating biomarker signatures from Megaplex to singleplex RT-qPCR platforms, based on the identification of a small number of normalizer miRNAs that closely track the mean of expressed miRNAs. Conclusions We developed the MCR method for normalizing miRNA expression from biofluids samples when using the TaqMan Megaplex RT-qPCR platform. Our results suggest that normalization based on the mean of all fully observed (fully detected miRNAs minimizes technical variance in normalized expression values, and that a small number of normalizer miRNAs can be selected when migrating from Megaplex to singleplex assays. In our study, we find that normalization methods that focus on a restricted set of miRNAs tend to perform better than methods that focus on all miRNAs, including

  17. Sample displacement chromatography as a method for purification of proteins and peptides from complex mixtures

    Science.gov (United States)

    Gajdosik, Martina Srajer; Clifton, James; Josic, Djuro

    2012-01-01

    Sample displacement chromatography (SDC) in reversed-phase and ion-exchange modes was introduced approximately twenty years ago. This method takes advantage of relative binding affinities of components in a sample mixture. During loading, there is a competition among different sample components for the sorption on the surface of the stationary phase. SDC was first used for the preparative purification of proteins. Later, it was demonstrated that this kind of chromatography can also be performed in ion-exchange, affinity and hydrophobic-interaction mode. It has also been shown that SDC can be performed on monoliths and membrane-based supports in both analytical and preparative scale. Recently, SDC in ion-exchange and hydrophobic interaction mode was also employed successfully for the removal of trace proteins from monoclonal antibody preparations and for the enrichment of low abundance proteins from human plasma. In this review, the principals of SDC are introduced, and the potential for separation of proteins and peptides in micro-analytical, analytical and preparative scale is discussed. PMID:22520159

  18. Surface and bulk 3D analysis of natural and processed ruby using electron probe micro analyzer and X-ray micro CT scan

    Energy Technology Data Exchange (ETDEWEB)

    Sahoo, Rakesh K., E-mail: rakesh.materialscience@gmail.com; Singh, Saroj K.; Mishra, B.K.

    2016-08-15

    Highlights: • Firm linking between two advance techniques: Micro-CT and EPMA for mineral analysis. • Attempt to identify and differentiate the treated gem stone from natural counterpart. • 3D structural and surface elemental analysis of the natural gem stone. - Abstract: The change in surface compositional and bulk structural characteristics of the natural ruby stone, before and after heat treatment with lead oxide has been analyzed using two advance characterization techniques like: X-ray micro CT scan (μ-CT) and electron probe micro analyzer (EPMA). The analytical correlation between these two techniques in identification as well as in depth study of the ores and minerals before and after processing has been presented. Also, we describe the aesthetic enhancement of a low quality defective ruby stone by lead oxide filling and the sequential analysis of this ruby stone before and after treatment using these two advanced techniques to identify and to confirm the change in its aesthetic value. The cracks healing and pores filling by the metal oxide on the surface of the ruby have been analyzed using μ-CT and EPMA. Moreover, in this work we describe the advance characterization of the repaired gem stones especially ruby stones. This work will light up the path for in-depth understanding of diffusion mechanism and abstract information of impurity particles inside the minerals. Based on these observations, EPMA and micro CT are shown to be powerful tools for the identification as well as research in gem stones.

  19. Micro-Crater Laser Induced Breakdown Spectroscopy--an Analytical approach in metals samples

    Energy Technology Data Exchange (ETDEWEB)

    Piscitelli, Vincent [UCV- Laboratorio de Espectroscopia Laser, Caracas (Venezuela); Lawrence Berkeley National laboratory, Berkeley, US (United States); Gonzalez, Jhanis; Xianglei, Mao; Russo, Richard [Lawrence Berkeley National laboratory, Berkeley, US (United States); Fernandez, Alberto [UCV- Laboratorio de Espectroscopia Laser, Caracas (Venezuela)

    2008-04-15

    The laser ablation has been increasing its popularity like as technique of chemical analysis. This is due to its great potentiality in the analysis of solid samples. On the way to contributing to the development of the technique, we in this work studied the laser induced breakdown spectroscopy (LIBS) in conditions of micro ablation for future studies of coverings and micro crates analysis. Craters between 2 and 7 micrometers of diameter were made using an Nd-YAG nanosecond laser in their fundamental emission of 1064 nm. In order to create these craters we use an objective lens of long distance work and 0.45 of numerical aperture. The atomic emission versus the energy of the laser and its effect on the size of craters was study. We found that below 3 micrometers although there was evidence of material removal by the formation of a crater, it was no detectable atomic emission for our instruments. In order to try to understand this, curves of size of crater versus plasma temperature using the Boltzmann distribution graphs taking the Copper emission lines in the visible region were made. In addition calibration curves for Copper and aluminum were made in two different matrices; one of it was a Cu/Zn alloy and the other a Zinc Matrix. The atomic lines Cu I (521.78 nm) and Al I (396.15 nm) was used. From the Calibration curve the analytical limit of detection and other analytical parameters were obtained.

  20. Micro-nano-bio acoustic system for the detection of foodborne pathogens in real samples.

    Science.gov (United States)

    Papadakis, George; Murasova, Pavla; Hamiot, Audrey; Tsougeni, Katerina; Kaprou, Georgia; Eck, Michael; Rabus, David; Bilkova, Zuzana; Dupuy, Bruno; Jobst, Gerhard; Tserepi, Angeliki; Gogolides, Evangelos; Gizeli, Electra

    2018-07-15

    The fast and efficient detection of foodborne pathogens is a societal priority, given the large number of food-poisoning outbreaks, and a scientific and technological challenge, given the need to detect as little as 1 viable cell in 25 gr of food. Here, we present the first approach that achieves the above goal, thanks to the use of a micro/nano-technology and the detection capability of acoustic wave sensors. Starting from 1 Salmonella cell in 25 ml of milk, we employ immuno-magnetic beads to capture cells after only 3 h of pre-enrichment and subsequently demonstrate efficient DNA amplification using the Loop Mediated Isothermal Amplification method (LAMP) and acoustic detection in an integrated platform, within an additional ½ h. The demonstrated 4 h sample-to-analysis time comes as a huge improvement to the current need of few days to obtain the same result. In addition, the work presents the first reported Lab-on-Chip platform that comprises an acoustic device as the sensing element, exhibiting impressive analytical features, namely, an acoustic limit of detection of 2 cells/μl or 3 aM of the DNA target and ability to detect in a label-free manner dsDNA amplicons in impure samples. The use of food samples together with the incorporation of the necessary pre-enrichment step and ability for multiple analysis with an internal control, make the proposed methodology highly relevant to real-world applications. Moreover, the work suggests that acoustic wave devices can be used as an attractive alternative to electrochemical sensors in integrated platforms for applications in food safety and the point-of-care diagnostics. Copyright © 2018. Published by Elsevier B.V.

  1. Comparison between thaw-mounting and use of conductive tape for sample preparation in ToF-SIMS imaging of lipids in Drosophila microRNA-14 model.

    Science.gov (United States)

    Le, Minh Uyen Thi; Son, Jin Gyeong; Shon, Hyun Kyoung; Park, Jeong Hyang; Lee, Sung Bae; Lee, Tae Geol

    2018-03-30

    Time-of-flight secondary ion mass spectrometry (ToF-SIMS) imaging elucidates molecular distributions in tissue sections, providing useful information about the metabolic pathways linked to diseases. However, delocalization of the analytes and inadequate tissue adherence during sample preparation are among some of the unfortunate phenomena associated with this technique due to their role in the reduction of the quality, reliability, and spatial resolution of the ToF-SIMS images. For these reasons, ToF-SIMS imaging requires a more rigorous sample preparation method in order to preserve the natural state of the tissues. The traditional thaw-mounting method is particularly vulnerable to altered distributions of the analytes due to thermal effects, as well as to tissue shrinkage. In the present study, the authors made comparisons of different tissue mounting methods, including the thaw-mounting method. The authors used conductive tape as the tissue-mounting material on the substrate because it does not require heat from the finger for the tissue section to adhere to the substrate and can reduce charge accumulation during data acquisition. With the conductive-tape sampling method, they were able to acquire reproducible tissue sections and high-quality images without redistribution of the molecules. Also, the authors were successful in preserving the natural states and chemical distributions of the different components of fat metabolites such as diacylglycerol and fatty acids by using the tape-supported sampling in microRNA-14 (miR-14) deleted Drosophila models. The method highlighted here shows an improvement in the accuracy of mass spectrometric imaging of tissue samples.

  2. Micro gravity - an important tool for development of advanced materials

    International Nuclear Information System (INIS)

    Sadiq, S.

    1995-01-01

    Microgravity provides the researchers the opportunity to investigate and improve the methods of creating advanced materials on earth. This can in turn assist in the advanced of economically significant technologies and technology infusement into the private sector. In some unique cases, involving inherently expensive materials that must have high purity, such as composites, high grade alloys etc. small amounts be made in space commercially and viably. A number of developed countries have gained sufficient expertise in material processing and other experiments under microgravity conditions, and their progress has been quite tremendous in this vital area of space research. The four important modes of platform, i.e., space shuttle/satellite, rocket flights, aircraft and drop tower tests have been employed for this purpose. Processing of materials in all such cases differs from the point of view of its cost effectiveness, time required to perform the expertise, instrumentation set up etc. In region of Far East and South East Asia, only one or two countries have made some advances in material processing experiments under microgravity conditions both in the upper atmosphere as well as using Drop Tower Test, but limited experimental means have made these countries to strive in this research area compared to work done in author advanced countries. The paper describes a brief history of microgravity experiments, their types and mode of transport employed for processing of novel materials under extreme low gravity or zero gravity conditions. This will definitely be useful and beneficial to developing nations of this region have entered an era of sophisticated and advanced materials processing and its utilization for industries such as aerospace, nuclear power plants, strategic materials, electronics, biological communication etc. (author)

  3. A Micro-Damage Detection Method of Litchi Fruit Using Hyperspectral Imaging Technology

    Directory of Open Access Journals (Sweden)

    Juntao Xiong

    2018-02-01

    Full Text Available The non-destructive testing of litchi fruit is of great significance to the fresh-keeping, storage and transportation of harvested litchis. To achieve quick and accurate micro-damage detection, a non-destructive grading test method for litchi fruits was studied using 400–1000 nm hyperspectral imaging technology. The Huaizhi litchi was chosen in this study, and the hyperspectral data average for the region of interest (ROI of litchi fruit was extracted for spectral data analysis. Then the hyperspectral data samples of fresh and micro-damaged litchi fruits were selected, and a partial least squares discriminant analysis (PLS-DA was used to establish a prediction model for the realization of qualitative analysis for litchis with different qualities. For the external validation set, the mean per-type recall and precision were 94.10% and 93.95%, respectively. Principal component analysis (PCA was used to determine the sensitive wavelength for recognition of litchi quality characteristics, with the results of wavelengths corresponding to the local extremum for the weight coefficient of PC3, i.e., 694, 725 and 798 nm. Then the single-band images corresponding to each sensitive wavelength were analyzed. Finally, the 7-dimension features of the PC3 image were extracted using the Gray Level Co-occurrence Matrix (GLCM. Through image processing, least squares support vector machine (LS-SVM modeling was conducted to classify the different qualities of litchis. The model was validated using the experiment data, and the average accuracy of the validation set was 93.75%, while the external validation set was 95%. The results indicate the feasibility of using hyperspectral imaging technology in litchi postpartum non-destructive detection and classification.

  4. Micro-powder injection moulding of tungsten

    International Nuclear Information System (INIS)

    Zeep, B.

    2007-12-01

    For He-cooled Divertors as integral components of future fusion power plants, about 300000 complex shaped tungsten components are to be fabricated. Tungsten is the favoured material because of its excellent properties (high melting point, high hardness, high sputtering resistance, high thermal conductivity). However, the material's properties cause major problems for large scale production of complex shaped components. Due to the resistance of tungsten to mechanical machining, new fabrication technologies have to be developed. Powder injection moulding as a well established shaping technology for a large scale production of complex or even micro structured parts might be a suitable method to produce tungsten components for fusion applications but is not yet commercially available. The present thesis is dealing with the development of a powder injection moulding process for micro structured tungsten components. To develop a suitable feedstock, the powder particle properties, the binder formulation and the solid load were optimised. To meet the requirements for a replication of micro patterned cavities, a special target was to define the smallest powder particle size applicable for micro-powder injection moulding. To investigate the injection moulding performance of the developed feedstocks, experiments were successfully carried out applying diverse cavities with structural details in micro dimension. For debinding of the green bodies, a combination of solvent debinding and thermal debinding has been adopted for injection moulded tungsten components. To develop a suitable debinding strategy, a variation of the solvent debinding time, the heating rate and the binder formulation was performed. For investigating the thermal consolidation behaviour of tungsten components, sinter experiments were carried out applying tungsten powders suitable for micro-powder injection moulding. First mechanical tests of the sintered samples showed promising material properties such as a

  5. Advanced Electrochemical Machining (ECM) for tungsten surface micro-structuring in blanket applications

    International Nuclear Information System (INIS)

    Holstein, Nils; Krauss, Wolfgang; Konys, Jürgen; Heuer, Simon; Weber, Thomas

    2016-01-01

    Highlights: • Electrochemical Machining is an appropriate tool for tungsten shaping. • Progress in shaping achieved by combination of ECM with advanced micro-lithography. • Application in First Wall for connection of plasma facing material to breeder blanket. • Successful development of adhesion promotors by ECM for plasma spraying interlayers. • Microstructure electrochemical manufacturing of tungsten in sizes of 100 μm achieved. - Abstract: Plasma facing components for fusion applications must have to exhibit long-term stability under extreme physical conditions, and therefore any material imperfections caused by mechanical and/or thermal stresses in the shaping processes cannot be tolerated due to a high risk of possible technical failures under fusion conditions. To avoid such defects, the method of Electrochemical Machining (ECM) enables a complete defect-free processing of removal of tungsten material during the desired shaping, also for high penetration depths. Furthermore, supported by lithographic mask pretreatment, three-dimensional distinct geometric structures can be positive-imaged via the directional galvanic dissolution applying M-ECM process into the tungsten bulk material. New required applications for tungsten components, e.g. as adhesion promotors in W-surfaces to enable sure grip and bonding of thick plasma-spraying layers for blanket components, will define the way of further miniaturization of well-established millimeter dimensioned M-ECM shaping processes to dimensions of 100 μm and furthermore down to 50 μm. Besides current M-ECM limits the article describes inevitable needs of further developments for mask resists, mask materials and the resulting ECM parameters, to reach the needed accuracy in tungsten microstructure. The achieved progress and observed correlations of processing parameters will be manifested by produced demonstrators made by the new “μM”-ECM process.

  6. Advanced Electrochemical Machining (ECM) for tungsten surface micro-structuring in blanket applications

    Energy Technology Data Exchange (ETDEWEB)

    Holstein, Nils, E-mail: nils.holstein@kit.edu [Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, D-76344 Eggenstein-Leopoldshafen, Baden-Württemberg (Germany); Krauss, Wolfgang; Konys, Jürgen [Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, D-76344 Eggenstein-Leopoldshafen, Baden-Württemberg (Germany); Heuer, Simon; Weber, Thomas [Research Center Jülich, Institute of Energy- and Climate Research – Plasma Physics (IEK-4), D-52425 Jülich (Germany)

    2016-11-01

    Highlights: • Electrochemical Machining is an appropriate tool for tungsten shaping. • Progress in shaping achieved by combination of ECM with advanced micro-lithography. • Application in First Wall for connection of plasma facing material to breeder blanket. • Successful development of adhesion promotors by ECM for plasma spraying interlayers. • Microstructure electrochemical manufacturing of tungsten in sizes of 100 μm achieved. - Abstract: Plasma facing components for fusion applications must have to exhibit long-term stability under extreme physical conditions, and therefore any material imperfections caused by mechanical and/or thermal stresses in the shaping processes cannot be tolerated due to a high risk of possible technical failures under fusion conditions. To avoid such defects, the method of Electrochemical Machining (ECM) enables a complete defect-free processing of removal of tungsten material during the desired shaping, also for high penetration depths. Furthermore, supported by lithographic mask pretreatment, three-dimensional distinct geometric structures can be positive-imaged via the directional galvanic dissolution applying M-ECM process into the tungsten bulk material. New required applications for tungsten components, e.g. as adhesion promotors in W-surfaces to enable sure grip and bonding of thick plasma-spraying layers for blanket components, will define the way of further miniaturization of well-established millimeter dimensioned M-ECM shaping processes to dimensions of 100 μm and furthermore down to 50 μm. Besides current M-ECM limits the article describes inevitable needs of further developments for mask resists, mask materials and the resulting ECM parameters, to reach the needed accuracy in tungsten microstructure. The achieved progress and observed correlations of processing parameters will be manifested by produced demonstrators made by the new “μM”-ECM process.

  7. Peptostreptococcus micros in primary endodontic infections as detected by 16S rDNA-based polymerase chain reaction.

    Science.gov (United States)

    Siqueira, José F; Rôças, Isabela N; Andrade, Arnaldo F B; de Uzeda, Milton

    2003-02-01

    A 16S rDNA-based polymerase chain reaction (PCR) method was used to detect Peptostreptococcus micros in primary root canal infections. Samples were collected from 50 teeth having carious lesions, necrotic pulps, and different forms of periradicular diseases. DNA extracted from the samples was amplified using the PCR assay, which yielded a specific fragment of P. micros 16S rDNA. P. micros was detected in 6 of 22 root canals associated with asymptomatic chronic periradicular lesions (27.3%), 2 of 8 teeth with acute apical periodontitis (25%), and 6 of 20 cases of acute periradicular abscess (30%). In general, P. micros was found in 14 of 50 cases (28%). There was no correlation between the presence of P. micros and the occurrence of symptoms. Findings suggested that P. micros can be involved in the pathogenesis of different forms of periradicular lesions.

  8. Optimized high-throughput microRNA expression profiling provides novel biomarker assessment of clinical prostate and breast cancer biopsies

    Directory of Open Access Journals (Sweden)

    Fedele Vita

    2006-06-01

    Full Text Available Abstract Background Recent studies indicate that microRNAs (miRNAs are mechanistically involved in the development of various human malignancies, suggesting that they represent a promising new class of cancer biomarkers. However, previously reported methods for measuring miRNA expression consume large amounts of tissue, prohibiting high-throughput miRNA profiling from typically small clinical samples such as excision or core needle biopsies of breast or prostate cancer. Here we describe a novel combination of linear amplification and labeling of miRNA for highly sensitive expression microarray profiling requiring only picogram quantities of purified microRNA. Results Comparison of microarray and qRT-PCR measured miRNA levels from two different prostate cancer cell lines showed concordance between the two platforms (Pearson correlation R2 = 0.81; and extension of the amplification, labeling and microarray platform was successfully demonstrated using clinical core and excision biopsy samples from breast and prostate cancer patients. Unsupervised clustering analysis of the prostate biopsy microarrays separated advanced and metastatic prostate cancers from pooled normal prostatic samples and from a non-malignant precursor lesion. Unsupervised clustering of the breast cancer microarrays significantly distinguished ErbB2-positive/ER-negative, ErbB2-positive/ER-positive, and ErbB2-negative/ER-positive breast cancer phenotypes (Fisher exact test, p = 0.03; as well, supervised analysis of these microarray profiles identified distinct miRNA subsets distinguishing ErbB2-positive from ErbB2-negative and ER-positive from ER-negative breast cancers, independent of other clinically important parameters (patient age; tumor size, node status and proliferation index. Conclusion In sum, these findings demonstrate that optimized high-throughput microRNA expression profiling offers novel biomarker identification from typically small clinical samples such as breast

  9. Evaluation of a X-ray imaging method in micro-fluidics: the case of T-shaped micro-channels filling up

    International Nuclear Information System (INIS)

    Vabre, A.; Legoupil, S.; Manach, E.; Gal, O.; Colin, St.; Geoffroy, S.; Gue, A.M.

    2006-01-01

    X-rays methods assessment in micro-fluidics: case of 'T' shaped microchannels filling. Fluid flows within 'T' or 'Y' shaped microchannels are deeply studied in order to develop adapted modeling approaches and experimental techniques. Our technological choice lies on the attenuation measurement of X-ray in matter. The main advantage of this non-intrusive technique is to be implemented on media opaque to visible light. Moreover, X-rays methods may achieve better spatial resolutions as compared to optical methods because of their much lower wavelength. In order to validate this X-ray method, measurements obtained by this technique are compared with direct measurements carried out on similar microchannels. Finally, experimental results are compared with a theoretical model. (author)

  10. Preparation and highlighted applications of magnetic microparticles and nanoparticles: a review on recent advances

    International Nuclear Information System (INIS)

    Xiao, Deli; Lu, Ting; Zeng, Rong; Bi, Yanping

    2016-01-01

    This review (with 144 refs.) focuses on the recent advances in the preparation and application of magnetic micro/nanoparticles. Specifically, it covers (a) methods for preparation (such as by coprecipitation, pyrolysis, hydrothermal, solvothermal, sol-gel, micro-emulsion, sonochemical, medium dispersing or emulsion polymerization methods), and (b) applications such as magnetic resonance imaging, magnetic separation of biomolecules (nucleic acids; proteins; cells), separation of metal ions and organic analytes, immobilization of enzymes, biological detection, magnetic catalysis and water treatment. Finally, the existing challenges and possible trends in the field are addressed. (author)

  11. An improved sampling method of complex network

    Science.gov (United States)

    Gao, Qi; Ding, Xintong; Pan, Feng; Li, Weixing

    2014-12-01

    Sampling subnet is an important topic of complex network research. Sampling methods influence the structure and characteristics of subnet. Random multiple snowball with Cohen (RMSC) process sampling which combines the advantages of random sampling and snowball sampling is proposed in this paper. It has the ability to explore global information and discover the local structure at the same time. The experiments indicate that this novel sampling method could keep the similarity between sampling subnet and original network on degree distribution, connectivity rate and average shortest path. This method is applicable to the situation where the prior knowledge about degree distribution of original network is not sufficient.

  12. Micro transflection on a metallic stick: an innovative approach of reflection infrared spectroscopy for minimally invasive investigation of painting varnishes.

    Science.gov (United States)

    Rosi, Francesca; Legan, Lea; Miliani, Costanza; Ropret, Polonca

    2017-05-01

    A new analytical approach, based on micro-transflection measurements from a diamond-coated metal sampling stick, is presented for the analysis of painting varnishes. Minimally invasive sampling is performed from the varnished surface using the stick, which is directly used as a transflection substrate for micro Fourier transform infrared (FTIR) measurements. With use of a series of varnished model paints, the micro-transflection method has been proved to be a valuable tool for the identification of surface components thanks to the selectivity of the sampling, the enhancement of the absorbance signal, and the easier spectral interpretation because the profiles are similar to transmission mode ones. Driven by these positive outcomes, the method was then tested as tool supporting noninvasive reflection FTIR spectroscopy during the assessment of varnish removal by solvent cleaning on paint models. Finally, the integrated analytical approach based on the two reflection methods was successfully applied for the monitoring of the cleaning of the sixteenth century painting Presentation in the Temple by Vittore Carpaccio. Graphical Abstract Micro-transflection FTIR on a metallic stick for the identification of varnishes during painting cleanings.

  13. Determination of elemental abundances in impact materials by micro-PIXE and micro-SRXRF methods

    International Nuclear Information System (INIS)

    Uzonyi, I.; Szabo, Gy.; Kiss, A.Z.; Szoeoer, Gy.; Rozsa, P.

    2004-01-01

    The most famous and well-preserved meteorite crater in the world is the Barringer Meteor Crater (Arizona, USA). The meteorite is supposed to be a fragment of a small asteroid of our solar system. During the impact event the matter of the projectile mixed with that of the target rocks forming breccias, slag and spherules. For the non-destructive characterization of the impact materials a combined micro-PIXE and micro-SRXRF technique was applied. (N.T.)

  14. Nozzle fabrication for Micro Propulsion of a Micro-Satellite

    NARCIS (Netherlands)

    Louwerse, M.C.; Jansen, Henricus V.; Groenendijk, M.N.W.; Elwenspoek, Michael Curt

    2008-01-01

    To enable formation flying of micro satellites, small sized propulsion systems are required. Our research focuses on the miniaturization of a feeding and thruster system by means of micro system technology (MST). Three fabrication methods have been investigated to make a conical converging-diverging

  15. Downregulation of six microRNAs is associated with advanced stage, lymph node metastasis and poor prognosis in small cell carcinoma of the cervix.

    Directory of Open Access Journals (Sweden)

    Long Huang

    Full Text Available BACKGROUND: Small cell carcinoma of the cervix (SCCC is very rare, and due to the long time period required to recruit sufficient numbers of patients, there is a paucity of information regarding the prognostic factors associated with survival. MicroRNAs (miRNAs have been used as cancer-related biomarkers in a variety of tumor types, and the objective of this study was to determine whether microRNA expression profiles can predict clinical outcome in SCCC. METHODOLOGY/PRINCIPAL FINDINGS: Forty-four patients with SCCC who underwent radical hysterectomy between January 2000 and October 2009 were enrolled. Using the GeneCopoeia All-in-One™ Customized Human qPCR Primer Array, the expression profiles of 30 miRNAs associated with tumor metastasis was obtained from the formalin-fixed paraffin embedded samples of all 44 patients. Seven miRNAs, has-let-7c, has-miR-10b, has-miR-100, has-miR-125b, has-miR-143, has-miR-145 and has-miR-199a-5p were significantly down-regulated in advanced stage SCCC patients (FIGO IB2-IV compared to early stage SCCC patients (FIGOIB1. Among, downregulation of six miRNAs, has-let-7c, has-miR-100, has-miR-125b, has-miR-143, has-miR-145 and has-miR-199a-5p were significantly associated with lymph node metastasis and reduced survival in SCCC. Kaplan-Meier survival analyses revealed that SCCC patients with low expression of has-miR-100 (P = 0.019 and has-miR-125b (P = 0.020 projected a significant tendency towards poorer prognosis. CONCLUSIONS/SIGNIFICANCE: This study demonstrates that downregulation of 7 miRNA associated with advanced stage, 6 miRNAs with metastasis and 2 with poor prognosis in SCCC. Functional analysis of these miRNAs may enhance our understanding of SCCC, as altered expression of specific miRNAs may regulate the metastatic pathway and provide novel targets for therapy.

  16. Advanced Computational Methods for Monte Carlo Calculations

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Forrest B. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2018-01-12

    This course is intended for graduate students who already have a basic understanding of Monte Carlo methods. It focuses on advanced topics that may be needed for thesis research, for developing new state-of-the-art methods, or for working with modern production Monte Carlo codes.

  17. Comparison of sampling methods for animal manure

    NARCIS (Netherlands)

    Derikx, P.J.L.; Ogink, N.W.M.; Hoeksma, P.

    1997-01-01

    Currently available and recently developed sampling methods for slurry and solid manure were tested for bias and reproducibility in the determination of total phosphorus and nitrogen content of samples. Sampling methods were based on techniques in which samples were taken either during loading from

  18. Characterizations of Stress and Strain Variation in Three-Dimensional Forming of Laser Micro-Manufacturing

    International Nuclear Information System (INIS)

    Ming, Zhou; Guo-Huan, Zhao; Tao, Huang; Hua, Ding; Lan, Cai

    2010-01-01

    A micro-manufacturing technology is presented to form three-dimensional metallic micro-structures directly. Micro grid array structures are replicated on a metallic foil surface, with high spatial resolution in micron levels. The numerical simulation results indicate that the material deformation process is characterized by an ultrahigh strain rate. With increasing pulse duration, the sample absorption strain energy increases, and the sample deformation degree enlarges. The stress state of the central point fluctuates between tensile stress and compression stress. The stress state of the angular point is altered from compressive stress to tensile stress due to geometry and loading conditions. The duration length of pulse stress has an effect on the stress state, as with the increase of pulse duration, fluctuation in the stress state decreases. Therefore, laser micro-manufacturing technology will be a potential laser micro forming method which is characterized by low cost and high efficiency. (fundamental areas of phenomenology(including applications))

  19. Effect of micro-computed tomography voxel size and segmentation method on trabecular bone microstructure measures in mice

    Directory of Open Access Journals (Sweden)

    Blaine A. Christiansen

    2016-12-01

    Full Text Available Micro-computed tomography (μCT is currently the gold standard for determining trabecular bone microstructure in small animal models. Numerous parameters associated with scanning and evaluation of μCT scans can strongly affect morphologic results obtained from bone samples. However, the effect of these parameters on specific trabecular bone outcomes is not well understood. This study investigated the effect of μCT scanning with nominal voxel sizes between 6–30 μm on trabecular bone outcomes quantified in mouse vertebral body trabecular bone. Additionally, two methods for determining a global segmentation threshold were compared: based on qualitative assessment of 2D images, or based on quantitative assessment of image histograms. It was found that nominal voxel size had a strong effect on several commonly reported trabecular bone parameters, in particular connectivity density, trabecular thickness, and bone tissue mineral density. Additionally, the two segmentation methods provided similar trabecular bone outcomes for scans with small nominal voxel sizes, but considerably different outcomes for scans with larger voxel sizes. The Qualitatively Selected segmentation method more consistently estimated trabecular bone volume fraction (BV/TV and trabecular thickness across different voxel sizes, but the Histogram segmentation method more consistently estimated trabecular number, trabecular separation, and structure model index. Altogether, these results suggest that high-resolution scans be used whenever possible to provide the most accurate estimation of trabecular bone microstructure, and that the limitations of accurately determining trabecular bone outcomes should be considered when selecting scan parameters and making conclusions about inter-group variance or between-group differences in studies of trabecular bone microstructure in small animals. Keywords: Trabecular bone, Microstructure, Micro-computed tomography, Voxel size, Resolution

  20. Advanced methods in diagnosis and therapy

    International Nuclear Information System (INIS)

    1987-01-01

    This important meeting covers the following topics: use and optimization of monoclonal antibobies in oncology: - Tumor markers: Clinical follow-up of patients through tumor marker serum determinations. - Cancer and medical imaging: The use of monoclonal antibodies in immunoscintigraphy. - Immunoradiotherapy: Monoclonal antibodies as therapeutic vectors. Advanced methods in diagnosis: - Contribution of monoclonal antibodies in modern immunochemistry (RIA, EIA). - Interest of monoclonal antibody in immunohistochemical pathology diagnosis. - In vitro diagnosis future prospects: with receptors and oncogenes. - Immunofluoroassay: a new sensitive immunoanalytical procedure with broad applications. Recent advances in brachitherapy: - Interest of computer processing. Blood products irradiation: - Interest in transfusion and bone marrow transplantations [fr

  1. Application of solid-phase micro extraction for the determination of pesticides in vegetable samples by gas chromatography with an electron capture detector

    International Nuclear Information System (INIS)

    Chai, Mee Kin; Tan, Guan Huat; Kumari, Asha

    2008-01-01

    A solid-phase micro extraction (SPME) method has been developed for the determination of 9 pesticides in 2 vegetables -cucumber and tomato - samples, based on direct immersion mode and subsequent desorption into the injection port of a gas chromatograph with an electron capture detector (GC-ECD). The main factors affecting the SPME process such as extraction time and temperature, desorption time and temperature, the effect of salt addition and fiber depth into the liner were studied and optimized. The analytical procedure proposed consisted of a 30 minute ultrasonic extraction of the target compounds from 1.0 g vegetable samples with 5 mL of distilled water. Then, the samples were filtered and topped up with distilled water to 10 mL. The analytes in this aqueous extract were extracted for 15 minutes with a 100 μm thickness polydimethylsiloxane SPME fiber. Relative standard deviations for triplicate analyses of samples were less than 10 %. The recoveries of the pesticides studied in cucumber and tomato ranged from 52 % to 82 % and the RSD were below 10 %. Therefore, the proposed method is applicable in the analysis of pesticides in vegetable matrices. SPME has been shown to be a simple extraction technique, which has a number of advantages such as solvent free extraction, simplicity and compatibility with the chromatographic analytical system. (author)

  2. The research of PSD location method in micro laser welding fields

    Science.gov (United States)

    Zhang, Qiue; Zhang, Rong; Dong, Hua

    2010-11-01

    In the field of micro laser welding, besides the special requirement in the parameter of lasers, the locating in welding points accurately is very important. The article adopt position sensitive detector (PSD) as hard core, combine optic system, electric circuits and PC and software processing, confirm the location of welding points. The signal detection circuits adopt the special integrate circuit H-2476 to process weak signal. It is an integrated circuit for high-speed, high-sensitivity optical range finding, which has stronger noiseproof feature, combine digital filter arithmetic, carry out repair the any non-ideal factors, increasing the measure precision. The amplifier adopt programmable amplifier LTC6915. The system adapt two dimension stepping motor drive the workbench, computer and corresponding software processing, make sure the location of spot weld. According to different workpieces to design the clamps. The system on-line detect PSD 's output signal in the moving processing. At the workbench moves in the X direction, the filaments offset is detected dynamic. Analyze the X axes moving sampling signal direction could be estimate the Y axes moving direction, and regulate the Y axes moving values. The workbench driver adopt A3979, it is a stepping motor driver with insert transducer and operate easily. It adapts the requirement of location in micro laser welding fields, real-time control to adjust by computer. It can be content up 20 μm's laser micro welding requirement on the whole. Using laser powder cladding technology achieve inter-penetration welding of high quality and reliability.

  3. From the sample preparation to the volume rendering images of small animals: A step by step example of a procedure to carry out the micro-CT study of the leafhopper insect Homalodisca vitripennis (Hemiptera: Cicadellidae)

    Science.gov (United States)

    Advances in micro-CT, digital computed tomography (CT) scan uses X-rays to make detailed pictures of structures inside of the body. Combining micro-CT with Digital Video Library systems, and linking this to Big Data, will change the way researchers, entomologist, and the public search and use anato...

  4. Nondestructive web thickness measurement of micro-drills with an integrated laser inspection system

    Science.gov (United States)

    Chuang, Shui-Fa; Chen, Yen-Chung; Chang, Wen-Tung; Lin, Ching-Chih; Tarng, Yeong-Shin

    2010-09-01

    Nowadays, the electric and semiconductor industries use numerous micro-drills to machine micro-holes in printed circuit boards. The measurement of web thickness of micro-drills, a key parameter of micro-drill geometry influencing drill rigidity and chip-removal ability, is quite important to ensure quality control. Traditionally, inefficiently destructive measuring method is adopted by inspectors. To improve quality and efficiency of the web thickness measuring tasks, a nondestructive measuring method is required. In this paper, based on the laser micro-gauge (LMG) and laser confocal displacement meter (LCDM) techniques, a nondestructive measuring principle of web thickness of micro-drills is introduced. An integrated laser inspection system, mainly consisting of a LMG, a LCDM and a two-axis-driven micro-drill fixture device, was developed. Experiments meant to inspect web thickness of micro-drill samples with a nominal diameter of 0.25 mm were conducted to test the feasibility of the developed laser inspection system. The experimental results showed that the web thickness measurement could achieve an estimated repeatability of ± 1.6 μm and a worst repeatability of ± 7.5 μm. The developed laser inspection system, combined with the nondestructive measuring principle, was able to undertake the web thickness measuring tasks for certain micro-drills.

  5. Micro-precipitation of Americium by Cerium Hydroxide for alpha spectrometry

    International Nuclear Information System (INIS)

    Wankhede, Sonal M.; Kumar, Suja A.; Sawant, Pramilla D.

    2018-01-01

    Estimation of trace amount of actinides in any biological and/or environmental sample is done by radiochemical separation followed by alpha spectrometry. Alpha-spectrometric determination of actinides requires thin, homogeneous and nearly weightless sample sources. The most widely used method for preparation of actinides for alpha spectrometry involves electro deposition of the alpha emitters using stainless steel planchetts (cathode) and platinum rod (anode). This procedure is time consuming, requires relatively elaborate equipment, and is expensive. Micro-precipitation technique using hydrofluoric acid (HF) is also reliable and already standardized at Bioassay Laboratory (Wankhede, 2016). However, it uses hazardous chemical such as HF, hence, in the present study, cerium hydroxide micro-precipitation technique was standardized

  6. Analytical performances of laser-induced micro-plasma of Al samples with single and double ultrashort pulses in air and with Ar-jet: A comparative study

    International Nuclear Information System (INIS)

    Semerok, A.; Dutouquet, C.

    2014-01-01

    Ultrashort pulse laser microablation coupled with optical emission spectroscopy was under study to obtain several micro-LIBS analytical features (shot-to-shot reproducibility, spectral line intensity and lifetime, calibration curves, detection limits). Laser microablation of Al matrix samples with known Cu- and Mg-concentrations was performed by single and double pulses of 50 fs and 1 ps pulse duration in air and with Ar-jet. The micro-LIBS analytical features obtained under different experimental conditions were characterized and compared. The highest shot-to-shot reproducibility and gain in plasma spectral line intensity were obtained with double pulses with Ar-jet for both 50 fs and 1 ps pulse durations. The best calibration curves were obtained with 1 ps pulse duration with Ar-jet. Micro-LIBS with ultrashort double pulses may find its effective application for surface elemental microcartography. - Highlights: • Analytical performances of micro-LIBS with ultrashort double pulses were studied. • The maximal line intensity gain of 20 was obtained with double pulses and Ar-jet. • LIBS gain was obtained without additional ablation of a sample by the second pulse. • LIBS properties were almost the same for both 50 fs and 1 ps pulses. • The micro-LIBS detection limit was around 35 ppm

  7. High pressure single-crystal micro X-ray diffraction analysis with GSE_ADA/RSV software

    Science.gov (United States)

    Dera, Przemyslaw; Zhuravlev, Kirill; Prakapenka, Vitali; Rivers, Mark L.; Finkelstein, Gregory J.; Grubor-Urosevic, Ognjen; Tschauner, Oliver; Clark, Simon M.; Downs, Robert T.

    2013-08-01

    GSE_ADA/RSV is a free software package for custom analysis of single-crystal micro X-ray diffraction (SCμXRD) data, developed with particular emphasis on data from samples enclosed in diamond anvil cells and subject to high pressure conditions. The package has been in extensive use at the high pressure beamlines of Advanced Photon Source (APS), Argonne National Laboratory and Advanced Light Source (ALS), Lawrence Berkeley National Laboratory. The software is optimized for processing of wide-rotation images and includes a variety of peak intensity corrections and peak filtering features, which are custom-designed to make processing of high pressure SCμXRD easier and more reliable.

  8. Micro-Organ Device

    Science.gov (United States)

    Gonda, Steve R. (Inventor); Chang, Robert C. (Inventor); Starly, Binil (Inventor); Culbertson, Christopher (Inventor); Holtorf, Heidi L. (Inventor); Sun, Wei (Inventor); Leslie, Julia (Inventor)

    2013-01-01

    A method for fabricating a micro-organ device comprises providing a microscale support having one or more microfluidic channels and one or more micro-chambers for housing a micro-organ and printing a micro-organ on the microscale support using a cell suspension in a syringe controlled by a computer-aided tissue engineering system, wherein the cell suspension comprises cells suspended in a solution containing a material that functions as a three-dimensional scaffold. The printing is performed with the computer-aided tissue engineering system according to a particular pattern. The micro-organ device comprises at least one micro-chamber each housing a micro-organ; and at least one microfluidic channel connected to the micro-chamber, wherein the micro-organ comprises cells arranged in a configuration that includes microscale spacing between portions of the cells to facilitate diffusion exchange between the cells and a medium supplied from the at least one microfluidic channel.

  9. Analysis of new actuation methods for capacitive shunt micro switchs

    Directory of Open Access Journals (Sweden)

    Ben Sassi S

    2016-01-01

    Full Text Available This work investigates the use of new actuation methods in capacitive shunt micro switches. We formulate the coupled electromechanical problem by taking into account the fringing effects and nonlinearities due to mid-plane stretching. Static analysis is undertaken using the Differential Quadrature Method (DQM to obtain the pull in voltage which is verified by means of the Finite Element Method (FEM. Based on Galerkin approximation, a single degree of freedom dynamic model is developed and limit-cycle solutions are calculated using the Finite Difference Method (FDM. In addition to the harmonic waveform signal, we apply novel actuation waveform signals to simulate the frequency-response. We show that, biased signals, using a square wave signal reduces significantly the pull-in voltage compared to the triangular and harmonic signal . Finally, these results are validated experimentally.

  10. Micro intelligence robot

    International Nuclear Information System (INIS)

    Jeon, Yon Ho

    1991-07-01

    This book gives descriptions of micro robot about conception of robots and micro robot, match rules of conference of micro robots, search methods of mazes, and future and prospect of robots. It also explains making and design of 8 beat robot like making technique, software, sensor board circuit, and stepping motor catalog, speedy 3, Mr. Black and Mr. White, making and design of 16 beat robot, such as micro robot artist, Jerry 2 and magic art of shortening distances algorithm of robot simulation.

  11. Sampling and sample processing in pesticide residue analysis.

    Science.gov (United States)

    Lehotay, Steven J; Cook, Jo Marie

    2015-05-13

    Proper sampling and sample processing in pesticide residue analysis of food and soil have always been essential to obtain accurate results, but the subject is becoming a greater concern as approximately 100 mg test portions are being analyzed with automated high-throughput analytical methods by agrochemical industry and contract laboratories. As global food trade and the importance of monitoring increase, the food industry and regulatory laboratories are also considering miniaturized high-throughput methods. In conjunction with a summary of the symposium "Residues in Food and Feed - Going from Macro to Micro: The Future of Sample Processing in Residue Analytical Methods" held at the 13th IUPAC International Congress of Pesticide Chemistry, this is an opportune time to review sampling theory and sample processing for pesticide residue analysis. If collected samples and test portions do not adequately represent the actual lot from which they came and provide meaningful results, then all costs, time, and efforts involved in implementing programs using sophisticated analytical instruments and techniques are wasted and can actually yield misleading results. This paper is designed to briefly review the often-neglected but crucial topic of sample collection and processing and put the issue into perspective for the future of pesticide residue analysis. It also emphasizes that analysts should demonstrate the validity of their sample processing approaches for the analytes/matrices of interest and encourages further studies on sampling and sample mass reduction to produce a test portion.

  12. Application of Micro-cloud point extraction for spectrophotometric determination of Malachite green, Crystal violet and Rhodamine B in aqueous samples

    Science.gov (United States)

    Ghasemi, Elham; Kaykhaii, Massoud

    2016-07-01

    A novel, green, simple and fast method was developed for spectrophotometric determination of Malachite green, Crystal violet, and Rhodamine B in water samples based on Micro-cloud Point extraction (MCPE) at room temperature. This is the first report on the application of MCPE on dyes. In this method, to reach the cloud point at room temperature, the MCPE procedure was carried out in brine using Triton X-114 as a non-ionic surfactant. The factors influencing the extraction efficiency were investigated and optimized. Under the optimized condition, calibration curves were found to be linear in the concentration range of 0.06-0.60 mg/L, 0.10-0.80 mg/L, and 0.03-0.30 mg/L with the enrichment factors of 29.26, 85.47 and 28.36, respectively for Malachite green, Crystal violet, and Rhodamine B. Limit of detections were between 2.2 and 5.1 μg/L.

  13. Betatron phase advance measurement at SPEAR

    International Nuclear Information System (INIS)

    Morton, P.L.; Pellegrin, J.L.; Raubenheimer, T.; Ross, M.

    1987-02-01

    There are many reasons to determine the betatron phase advance between two azimuthal positions in a circular accelerator or storage ring. We have measured the betatron phase advance between various pairs of azimuthal points in the SPEAR Storage Ring by two different methods. The first method is to excite a steady state coherent betatron oscillation with a network analyzer. The second method is to excite a free coherent betatron oscillation with an impulse kick, and to digitally sample the transverse position of the beam at the pickup stations. The results of these digital samples are Fourier analyzed with a computer to obtain the phase advance. The second method is discussed, and the experimental results compared to theory

  14. Betatron phase advance measurement at SPEAR

    International Nuclear Information System (INIS)

    Morton, P.L.; Pellegrin, J.L.; Raubenheimer, T.; Ross, M.

    1987-01-01

    There are many reasons to determine the betatron phase advance between two azimuthal positions in a circular accelerator or storage ring. The authors measured the betatron phase advance between various pairs of azimuthal points in the SPEAR Storage Ring by two different methods. The first method is to excite a steady state coherent betatron oscillation with a network analyzer. The second method is to excite a free coherent betatron oscillation with an impulse kick, and to digitally sample the transverse position of the beam at the pickup stations. The results of these digital samples are Fourier analyzed with a computer to obtain the phase advance. The second method is discussed, and the experimental results compared to theory

  15. Advances in iterative methods

    International Nuclear Information System (INIS)

    Beauwens, B.; Arkuszewski, J.; Boryszewicz, M.

    1981-01-01

    Results obtained in the field of linear iterative methods within the Coordinated Research Program on Transport Theory and Advanced Reactor Calculations are summarized. The general convergence theory of linear iterative methods is essentially based on the properties of nonnegative operators on ordered normed spaces. The following aspects of this theory have been improved: new comparison theorems for regular splittings, generalization of the notions of M- and H-matrices, new interpretations of classical convergence theorems for positive-definite operators. The estimation of asymptotic convergence rates was developed with two purposes: the analysis of model problems and the optimization of relaxation parameters. In the framework of factorization iterative methods, model problem analysis is needed to investigate whether the increased computational complexity of higher-order methods does not offset their increased asymptotic convergence rates, as well as to appreciate the effect of standard relaxation techniques (polynomial relaxation). On the other hand, the optimal use of factorization iterative methods requires the development of adequate relaxation techniques and their optimization. The relative performances of a few possibilities have been explored for model problems. Presently, the best results have been obtained with optimal diagonal-Chebyshev relaxation

  16. Sequential extraction of heavy metals from urban dust and street sediments. Pt. 1. Sequential extraction of heavy metals in micro samples; Sequentielle Schwermetallextraktion aus Staubniederschlaegen und Strassensedimenten. T. 1. Sequentielle Schwermetallextraktion von Mikroproben

    Energy Technology Data Exchange (ETDEWEB)

    Heiser, U.; Norra, S.; Stueben, D.; Wagner, M. von [Karlsruhe Univ. (T.H.) (Germany). Inst. fuer Petrographie und Geochemie

    1999-01-01

    For the application of sequential extraction of heavy metals from samples that can only be obtained in amounts of a few milligrams (micro samples, e.g. airborne dust fallout), the method after Zeien and Bruemmer (1989) was progressed. A down scale to 1:100 was carried out and the accuracy of this method with variable sample amounts of about 20 mg and an extraction volume of 500 {mu}l was proofed with standard soil samples. The influence of variable extraction ratios (ratio of sample amount and volume of extraction solvent) and the influence of intensive treatment of dust sampled by the Bergerhoff-method (VDI 2119/2, 1972) prior sequential extraction, was within the precision of measurement of our method. Thus, we showed that sequential extraction can be applied for the investigation of heavy metal mobilization in micro samples with variable sample amounts. A first application of our method for microsamples was carried out to investigate airborne dust fallout and street sediments at two urban sites where different heavy metal immission rates due to traffic influence occur. These investigations will be presented in part 2 (`Sequential extraxction of heavy metals from urban dust`). (orig.) [Deutsch] Fuer die Anwendung der sequentiellen Schwermetallextraktion auf Proben, die nur im Milligramm-Bereich erhalten werden koennen (Mikroproben, wie z.B. Staubniederschlaege), wurde die Methode von Zeien und Bruemmer (1989) weiterentwickelt. Der Extraktionsmassstab wurde um den Faktor 1:100 verringert und die Reproduzierbarkeit des Verfahrens mit variablen Probenmengen um 20 mg und einem Extraktionsvolumen von 500 {mu}l mit Hilfe von Standardboeden nachgewiesen. Moegliche Einfluesse variabler Extraktionsverhaeltnisse (Verhaeltnis von Probenmenge zu Extraktionsvolumen) sowie eine aufwendige Vorbehandlung von Staubproben, die nach der Bergerhoff-Methode (VDI 2119/2, 1972) gesammelt wurden, lagen bei diesen Untersuchungen weitgehend im Variationsbereich des Verfahrens. Die

  17. New method for monitoring nitric oxide in vivo using microdialysis sampling and chemiluminescence reaction

    Science.gov (United States)

    Yao, Dachun; Evmiridis, Nick P.; Zhou, Yikai; Xu, Shunqing; Zhou, Huarong

    2001-09-01

    A new method employing a combination of micro dialysis sampling and chemiluminescence reaction was developed to monitor nitric oxide (NO) in vivo. A special probe was designed with an interference-free membrane to achieve a very high selectivity for NO. High sensitivity was achieved by optimizing the working system and improving the NO sampling time. This system was used in vivo to monitor blood and brain tissue in rats and rabbits. We have established that this system is sensitive enough to detect variations in NO production in difference physiological state. The system can detect NO in the linear range of 5nM-1(mu) M, with a detection limit of 1nM, and real NO concentrations in our experimental animals were found to be in the range of 1-5 nM or even less. Finally, the effects of body temperature, NO donors, Viagra, NO activators, NO cofactors, NO interference were investigated carefully in different physiological situations.

  18. Micro-incubator for bacterial biosensing applications

    Science.gov (United States)

    Clasen, Estine; Land, Kevin; Joubert, Trudi-Heleen

    2016-02-01

    The presence of Escherichia coli (E. coli ) is a commonly used indicator micro-organism to determine whether water is safe for human consumption.1 This paper discusses the design of a micro-incubator that can be applied to concentrate bacteria prior to environmental water quality screening tests. High sensitivity and rapid test time is essential and there is a great need for these tests to be implemented on-site without the use of a laboratory infrastructure. In the light of these requirements, a mobile micro-incubator was designed, manufactured and characterised. A polydimethylsiloxane (PDMS) receptacle has been designed to house the 1-5 ml cell culture sample.2 A nano-silver printed electronics micro-heater has been designed to incubate the bacterial sample, with an array of temperature sensors implemented to accurately measure the sample temperature at various locations in the cell culture well. The micro-incubator limits the incubation temperature range to 37+/-3 °C in order to ensure near optimal growth of the bacteria at all times.3 The incubation time is adjustable between 30 minutes and 9 hours with a maximum rise time of 15 minutes to reach the set-point temperature. The surface area of the printed nano silver heating element is 500 mm2. Electrical and COMSOL Multiphysics simulations are included in order to give insight on micro-incubator temperature control. The design and characterization of this micro-incubator allows for further research in biosensing applications.

  19. Micro-Scale Avionics Thermal Management

    Science.gov (United States)

    Moran, Matthew E.

    2001-01-01

    Trends in the thermal management of avionics and commercial ground-based microelectronics are converging, and facing the same dilemma: a shortfall in technology to meet near-term maximum junction temperature and package power projections. Micro-scale devices hold the key to significant advances in thermal management, particularly micro-refrigerators/coolers that can drive cooling temperatures below ambient. A microelectromechanical system (MEMS) Stirling cooler is currently under development at the NASA Glenn Research Center to meet this challenge with predicted efficiencies that are an order of magnitude better than current and future thermoelectric coolers.

  20. Micro-fabricated silicon devices for advanced thermal management and integration of particle tracking detectors

    CERN Document Server

    Romagnoli, Giulia; Gambaro, Carla

    Since their first studies targeting the cooling of high-power computing chips, micro-channel devices are proven to provide a very efficient cooling system. In the last years micro-channel cooling has been successfully applied to the cooling of particle detectors at CERN. Thanks to their high thermal efficiency, they can guarantee a good heat sink for the cooling of silicon trackers, fundamental for the reduction of the radiation damage caused by the beam interactions. The radiation damage on the silicon detector is increasing with temperature and furthermore the detectors are producing heat that should be dissipated in the supporting structure. Micro-channels guarantee a distributed and uniform thermal exchange, thanks to the high flexibility of the micro-fabrication process that allows a large variety of channel designs. The thin nature of the micro-channels etched inside silicon wafers, is fulfilling the physics requirement of minimization of the material crossed by the particle beam. Furthermore micro-chan...

  1. Characterization of impact materials around Barringer Meteor Crater by micro-PIXE and micro-SRXRF techniques

    Energy Technology Data Exchange (ETDEWEB)

    Uzonyi, I. E-mail: uzonyi@atomki.hu; Szoeor, Gy.; Rozsa, P.; Vekemans, B.; Vincze, L.; Adams, F.; Drakopoulos, M.; Somogyi, A.; Kiss, A.Z

    2004-06-01

    A combined micro-PIXE and micro-SRXRF method has been tested successfully for the characterization of impact materials collected at the well-known Barringer Meteor Crater. The micro-PIXE technique proved to be sensitive in the Z{<=}28 atomic number region while the micro-SRXRF above Fe especially for the siderophile elements. Quantitative analysis has become available for about 40 elements by these complementary methods providing new perspectives for the interpretation of the formation mechanism of impact metamorphosed objects.

  2. Use of semiconductor detector c-Si microstrip type in obtaining the digital radiographic imaging of phantoms and biological samples of mammary glands

    International Nuclear Information System (INIS)

    Leyva, A.; Cabal, A.; Pinera, I.; Abreu, Y.; Cruz, C. M.; Montano, L. M.; Diaz, C. C.; Fontaine, M.; Ortiz, C. M.; Padilla, F.; De la Mora, R.

    2009-01-01

    The present work synthesizes the experimental results obtained in the characterization of 64 micro strips crystalline silicon detector designed for experiments in high energies physics, with the objective of studying its possible application in advanced medical radiography, specifically in digital mammography and angiography. The research includes the acquisition of two-dimensional radiography of a mammography phantom using the scanning method, and its comparison with similar images simulated mathematically for different X rays sources. The paper also shows the experimental radiography of two biological samples taken from biopsies of mammas, where it is possible to identify the presence of possible pathological lesions. The results reached in this work point positively toward the effective possibility of satisfactorily introducing those advanced detectors in medical digital imaging applications. (Author)

  3. Design related aspects in advanced nuclear fission plants

    International Nuclear Information System (INIS)

    Hoffelner, Wolfgang

    2011-01-01

    Important issues to be considered for design of future reactors are: extrapolation of stress rupture data, creep-fatigue, negligible creep, damage monitoring. The paper highlights some new developments taking examples from a martensitic steel (mod 9% Cr), oxide dispersion strengthened (ODS) steels and nickel-base superalloys. Traditional approaches to extrapolation of (thermal) stress rupture data like Larson-Miller Parameter or Monkman-Grant rule seem to be valid concepts also for advanced reactors. However, a significant influence of cyclic softening on creep rates and stress rupture data can be expected as shown for grade 91. This is particularly true for creep-fatigue interactions. Based on cyclic stress-strain behaviour it is also possible to get very good life-time predictions under creep-fatigue with a strain range separation (inelastic fatigue and creep ranges) technique which could replace the currently used linear life fraction rule. Results from in-beam irradiation creep reveal no significant influence of dispersoid size. It can be assumed that irradiation creep is a matrix property. Finally it is shown that micro-sample testing of exposed material could be used as an advanced method for damage assessment in future nuclear power plants.

  4. Updating the Micro-Tom TILLING platform.

    Science.gov (United States)

    Okabe, Yoshihiro; Ariizumi, Tohru; Ezura, Hiroshi

    2013-03-01

    The dwarf tomato variety Micro-Tom is regarded as a model system for functional genomics studies in tomato. Various tomato genomic tools in the genetic background of Micro-Tom have been established, such as mutant collections, genome information and a metabolomic database. Recent advances in tomato genome sequencing have brought about a significant need for reverse genetics tools that are accessible to the larger community, because a great number of gene sequences have become available from public databases. To meet the requests from the tomato research community, we have developed the Micro-Tom Targeting-Induced Local Lesions IN Genomes (TILLING) platform, which is comprised of more than 5000 EMS-mutagenized lines. The platform serves as a reverse genetics tool for efficiently identifying mutant alleles in parallel with the development of Micro-Tom mutant collections. The combination of Micro-Tom mutant libraries and the TILLING approach enables researchers to accelerate the isolation of desirable mutants for unraveling gene function or breeding. To upgrade the genomic tool of Micro-Tom, the development of a new mutagenized population is underway. In this paper, the current status of the Micro-Tom TILLING platform and its future prospects are described.

  5. Magnetic particle mixing with magnetic micro-convection for microfluidics

    International Nuclear Information System (INIS)

    Kitenbergs, Guntars; Erglis, Kaspars; Perzynski, Régine; Cēbers, Andrejs

    2015-01-01

    In this paper we discuss the magnetic micro-convection phenomenon as a tool for mixing enhancement in microfluidics systems in cases when one of the miscible fluids is a magnetic particle colloid. A system of a water-based magnetic fluid and water is investigated experimentally under homogeneous magnetic field in a Hele–Shaw cell. Subsequent image analysis both qualitatively and quantitatively reveals the high enhancement of mixing efficiency provided by this method. The mixing efficiency dependence on the magnetic field and the physical limits is discussed. A suitable model for a continuous-flow microfluidics setup for mixing with magnetic micro-convection is also proposed and justified with an experiment. In addition, possible applications in improving the speed of ferrohydrodynamic sorting and magnetic label or selected tracer mixing in lab on a chip systems are noted. - Highlights: • We study the magnetic micro-convection as a mixing method in microfluidics. • We show that the method enhances mixing with magnetic field squared dependency. • We propose a flow cell setup for mixing and justify it with a sample experiment. • The mixing method can be easily implemented in an existing microfluidics setup

  6. Advances in Imaging Approaches to Fracture Risk Evaluation

    Science.gov (United States)

    Manhard, Mary Kate; Nyman, Jeffry S.; Does, Mark D.

    2016-01-01

    Fragility fractures are a growing problem worldwide, and current methods for diagnosing osteoporosis do not always identify individuals who require treatment to prevent a fracture and may misidentify those not a risk. Traditionally, fracture risk is assessed using dual-energy X-ray absorptiometry, which provides measurements of areal bone mineral density (BMD) at sites prone to fracture. Recent advances in imaging show promise in adding new information that could improve the prediction of fracture risk in the clinic. As reviewed herein, advances in quantitative computed tomography (QCT) predict hip and vertebral body strength; high resolution HR-peripheral QCT (HR-pQCT) and micro-magnetic resonance imaging (μMRI) assess the micro-architecture of trabecular bone; quantitative ultrasound (QUS) measures the modulus or tissue stiffness of cortical bone; and quantitative ultra-short echo time MRI methods quantify the concentrations of bound water and pore water in cortical bone, which reflect a variety of mechanical properties of bone. Each of these technologies provides unique characteristics of bone and may improve fracture risk diagnoses and reduce prevalence of fractures by helping to guide treatment decisions. PMID:27816505

  7. Surface-Enhanced Raman Scattering of Bacteria in Micro wells Constructed from Silver Nanoparticles

    International Nuclear Information System (INIS)

    Culha, M.; Yazici, M.M.; Kahraman, M.; Sahin, F.; Sesin Kocagoz, S.

    2012-01-01

    Whole bacterial cell characterization is critically important for fast bacterial identification. Surface-enhanced Raman scattering (SERS) is proven to be powerful technique to serve such a goal. In this study, the characterization of whole bacterial cells in the micro wells constructed from colloidal silver nanoparticles (AgNPs) with convective-assembly method is reported.- The proper size of the micro wells for the model bacteria, Escherichia coli and Staphylococcus cohnii, is determined to be 1.2μm from their electron microscopy images. A minimum dilution factor of 20 is necessary for the bacterial samples collected from growth media to diminish the bacterial aggregation to place the bacterial cells into the micro wells. The constructed micro well structures are tested for their bacterial SERS performance and compared to the SERS spectra obtained from the samples prepared with a simple mixing of bacteria and AgNPs for the same bacteria. The results indicate that micro well structures not only improve the spectral quality but also increase the reproducibility of the SERS spectra.

  8. MicroRNAs expression profile in solid and unicystic ameloblastomas

    Science.gov (United States)

    Setién-Olarra, A.; Bediaga, N. G.; Aguirre-Echebarria, P.; Aguirre-Urizar, J. M.; Mosqueda-Taylor, A.

    2017-01-01

    Objectives Odontogenic tumors (OT) represent a specific pathological category that includes some lesions with unpredictable biological behavior. Although most of these lesions are benign, some, such as the ameloblastoma, exhibit local aggressiveness and high recurrence rates. The most common types of ameloblastoma are the solid/multicystic (SA) and the unicystic ameloblastoma (UA); the latter considered a much less aggressive entity as compared to the SA. The microRNA system regulates the expression of many human genes while its deregulation has been associated with neoplastic development. The aim of the current study was to determine the expression profiles of microRNAs present in the two most common types of ameloblastomas. Material & methods MicroRNA expression profiles were assessed using TaqMan® Low Density Arrays (TLDAs) in 24 samples (8 SA, 8 UA and 8 control samples). The findings were validated using quantitative RTqPCR in an independent cohort of 19 SA, 8 UA and 19 dentigerous cysts as controls. Results We identified 40 microRNAs differentially regulated in ameloblastomas, which are related to neoplastic development and differentiation, and with the osteogenic process. Further validation of the top ranked microRNAs revealed significant differences in the expression of 6 of them in relation to UA, 7 in relation to SA and 1 (miR-489) that was related to both types. Conclusion We identified a new microRNA signature for the ameloblastoma and for its main types, which may be useful to better understand the etiopathogenesis of this neoplasm. In addition, we identified a microRNA (miR-489) that is suggestive of differentiating among solid from unicystic ameloblastoma. PMID:29053755

  9. The MicroBooNE Technical Design Report

    Energy Technology Data Exchange (ETDEWEB)

    Fleming, Bonnie [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)

    2012-02-24

    MicroBooNE will build, operate, and extract physics from the first large liquid argon time projection chamber (LArTPC) that will be exposed to a high-intensity neutrino beam. With its unparalleled capabilities in tracking, vertexing, calorimetry, and particle identification, all with full electronic readout, MicroBooNE represents a major advance in detector technology for neutrino physics in the energy regime of most importance for elucidating oscillation phenomena.

  10. Geometry and surface damage in micro electrical discharge machining of micro-holes

    Science.gov (United States)

    Ekmekci, Bülent; Sayar, Atakan; Tecelli Öpöz, Tahsin; Erden, Abdulkadir

    2009-10-01

    Geometry and subsurface damage of blind micro-holes produced by micro electrical discharge machining (micro-EDM) is investigated experimentally to explore the relational dependence with respect to pulse energy. For this purpose, micro-holes are machined with various pulse energies on plastic mold steel samples using a tungsten carbide tool electrode and a hydrocarbon-based dielectric liquid. Variations in the micro-hole geometry, micro-hole depth and over-cut in micro-hole diameter are measured. Then, unconventional etching agents are applied on the cross sections to examine micro structural alterations within the substrate. It is observed that the heat-damaged segment is composed of three distinctive layers, which have relatively high thicknesses and vary noticeably with respect to the drilling depth. Crack formation is identified on some sections of the micro-holes even by utilizing low pulse energies during machining. It is concluded that the cracking mechanism is different from cracks encountered on the surfaces when machining is performed by using the conventional EDM process. Moreover, an electrically conductive bridge between work material and debris particles is possible at the end tip during machining which leads to electric discharges between the piled segments of debris particles and the tool electrode during discharging.

  11. Geometry and surface damage in micro electrical discharge machining of micro-holes

    International Nuclear Information System (INIS)

    Ekmekci, Bülent; Sayar, Atakan; Öpöz, Tahsin Tecelli; Erden, Abdulkadir

    2009-01-01

    Geometry and subsurface damage of blind micro-holes produced by micro electrical discharge machining (micro-EDM) is investigated experimentally to explore the relational dependence with respect to pulse energy. For this purpose, micro-holes are machined with various pulse energies on plastic mold steel samples using a tungsten carbide tool electrode and a hydrocarbon-based dielectric liquid. Variations in the micro-hole geometry, micro-hole depth and over-cut in micro-hole diameter are measured. Then, unconventional etching agents are applied on the cross sections to examine micro structural alterations within the substrate. It is observed that the heat-damaged segment is composed of three distinctive layers, which have relatively high thicknesses and vary noticeably with respect to the drilling depth. Crack formation is identified on some sections of the micro-holes even by utilizing low pulse energies during machining. It is concluded that the cracking mechanism is different from cracks encountered on the surfaces when machining is performed by using the conventional EDM process. Moreover, an electrically conductive bridge between work material and debris particles is possible at the end tip during machining which leads to electric discharges between the piled segments of debris particles and the tool electrode during discharging

  12. Micro/nano-fabrication technologies for cell biology.

    Science.gov (United States)

    Qian, Tongcheng; Wang, Yingxiao

    2010-10-01

    Micro/nano-fabrication techniques, such as soft lithography and electrospinning, have been well-developed and widely applied in many research fields in the past decade. Due to the low costs and simple procedures, these techniques have become important and popular for biological studies. In this review, we focus on the studies integrating micro/nano-fabrication work to elucidate the molecular mechanism of signaling transduction in cell biology. We first describe different micro/nano-fabrication technologies, including techniques generating three-dimensional scaffolds for tissue engineering. We then introduce the application of these technologies in manipulating the physical or chemical micro/nano-environment to regulate the cellular behavior and response, such as cell life and death, differentiation, proliferation, and cell migration. Recent advancement in integrating the micro/nano-technologies and live cell imaging are also discussed. Finally, potential schemes in cell biology involving micro/nano-fabrication technologies are proposed to provide perspectives on the future research activities.

  13. Advanced statistical methods in data science

    CERN Document Server

    Chen, Jiahua; Lu, Xuewen; Yi, Grace; Yu, Hao

    2016-01-01

    This book gathers invited presentations from the 2nd Symposium of the ICSA- CANADA Chapter held at the University of Calgary from August 4-6, 2015. The aim of this Symposium was to promote advanced statistical methods in big-data sciences and to allow researchers to exchange ideas on statistics and data science and to embraces the challenges and opportunities of statistics and data science in the modern world. It addresses diverse themes in advanced statistical analysis in big-data sciences, including methods for administrative data analysis, survival data analysis, missing data analysis, high-dimensional and genetic data analysis, longitudinal and functional data analysis, the design and analysis of studies with response-dependent and multi-phase designs, time series and robust statistics, statistical inference based on likelihood, empirical likelihood and estimating functions. The editorial group selected 14 high-quality presentations from this successful symposium and invited the presenters to prepare a fu...

  14. Textural Evolution During Micro Direct Metal Deposition of NiTi Alloy

    Science.gov (United States)

    Khademzadeh, Saeed; Bariani, Paolo F.; Bruschi, Stefania

    2018-03-01

    In this research, a micro direct metal deposition process, newly developed as a potential method for micro additive manufacturing was used to fabricate NiTi builds. The effect of scanning strategy on grain growth and textural evolution was investigated using scanning electron microscope equipped with electron backscattered diffraction detector. Investigations showed that, the angle between the successive single tracks has an important role in grain size distribution and textural evolution of NiTi phase. Unidirectional laser beam scanning pattern developed a fiber texture; conversely, a backward and forward scanning pattern developed a strong ‖‖ RD texture on the surface of NiTi cubic samples produced by micro direct metal deposition.

  15. Micro-bridge defects: characterization and root cause analysis

    Science.gov (United States)

    Santoro, Gaetano; Van den Heuvel, Dieter; Braggin, Jennifer; Rosslee, Craig; Leray, Philippe J.; Cheng, Shaunee; Jehoul, Christiane; Schreutelkamp, Robert; Hillel, Noam

    2010-03-01

    Defect review of advanced lithography processes is becoming more and more challenging as feature sizes decrease. Previous studies using a defect review SEM on immersion lithography generated wafers have resulted in a defect classification scheme which, among others, includes a category for micro-bridges. Micro-bridges are small connections between two adjacent lines in photo-resist and are considered device killing defects. Micro-bridge rates also tend to increase as feature sizes decrease, making them even more important for the next technology nodes. Especially because micro-bridge defects can originate from different root causes, the need to further refine and split up the classification of this type of defect into sub groups may become a necessity. This paper focuses on finding the correlation of the different types of micro-bridge defects to a particular root cause based on a full characterization and root cause analysis of this class of defects, by using advanced SEM review capabilities like high quality imaging in very low FOV, Multi Perspective SEM Imaging (MPSI), tilted column and rotated stage (Tilt&Rotation) imaging and Focused Ion Beam (FIB) cross sectioning. Immersion lithography material has been mainly used to generate the set of data presented in this work even though, in the last part of the results, some EUV lithography data will be presented as part of the continuing effort to extend the micro-bridge defect characterization to the EUV technology on 40 nm technology node and beyond.

  16. Design and fabrication of self-powered micro-harvesters rotating and vibrated micro-power systems

    CERN Document Server

    Pan, C T; Lin, Liwei; Chen, Ying-Chung

    2013-01-01

    Presents the latest methods for designing and fabricating self-powered micro-generators and energy harvester systems Design and Fabrication of Self-Powered Micro-Harvesters introduces the latest trends of self-powered generators and energy harvester systems, including the design, analysis and fabrication of micro power systems. Presented in four distinct parts, the authors explore the design and fabrication of: vibration-induced electromagnetic micro-generators; rotary electromagnetic micro-generators; flexible piezo-micro-generator with various widths; and PVDF electrospunpiezo-energy with

  17. Métodos alternativos para contagem de micro-organismos em carcaças suínas Alternative methods for the enumeration of microorganisms in swine carcasses

    Directory of Open Access Journals (Sweden)

    Cristhiane Stecanella de Oliveira Cattani

    2013-06-01

    programs check for contamination in raw materials and final products to ensure the safety of consumer products; for this reason, the use of alternative methods instead of the conventional methods used in routine diagnostic laboratories is necessary to obtain reliable results in the shortest time possible. Samples of pig carcasses were collected in a slaughterhouse with Federal Inspection in the State of Santa Catarina, Brazil. Mesophilic micro-organisms, Enterobacteriaceae and Escherichia coli were evaluated and tests performed by alternative methods, TEMPO®, Petrifilm™, and the conventional method of counting micro-organisms in Petri dishes. After statistical analysis, the Pearson correlation coefficient (r showed a strong correlation up to 0.70 between the methodologies used for the enumeration of Enterobacteriaceae and mesophilic micro-organisms, show a moderate correlation between 0.30 to 0.70, for the diagnosis of Escherichia coli. The use of alternative methods to replace the conventional method can be recommended for diagnosis of Escherichiacoli, Enterobacteriaceae and mesophilic micro-organisms, because there was consistency between the results and the speed was increased by the alternative methodologies benefiting the pork industry.

  18. Surface micro-dissolve method of imparting self-cleaning property to cotton fabrics in NaOH/urea aqueous solution

    Energy Technology Data Exchange (ETDEWEB)

    Fan, Tao; Hu, Ruimin; Zhao, Zhenyun [College of Textile & Garment, Southwest University, 400716, Chongqing (China); Liu, Yiping [College of Textile & Garment, Southwest University, 400716, Chongqing (China); Chongqing Engineering Research Center of Biomaterial Fiber and Modern Textile, 400716, Chongqing (China); Lu, Ming, E-mail: lumingswu@163.com [College of Textile & Garment, Southwest University, 400716, Chongqing (China); Chongqing Engineering Research Center of Biomaterial Fiber and Modern Textile, 400716, Chongqing (China)

    2017-04-01

    Highlights: • A novel micro-dissolved process was carried out to embedding commercial titanium dioxide nanoparticles into cotton fabric with NaOH/urea aqueous solution. • X-ray diffraction pattern of modified fabrics shown that the cellulose structure of modified fabrics had not changed. • Modified cotton fabrics demonstrated favourable photocatalytic self-cleaning performance while tensile strength and whiteness of treated fabrics also expressed an increasement slightly. - Abstract: A simple and economical micro-dissolved process of embedding titanium dioxide (TiO{sub 2}) nanoparticles into surface zone of cotton fabrics was developed. TiO{sub 2} was coated on cotton fabrics in 7% wt NaOH/12% wt urea aqueous solution at low temperature. Photocatalytic efficiency of cotton fabrics treated with TiO{sub 2} nanoparticles was studied upon measuring the photocatalytic decoloration of Rhodamine B (RhB) under ultraviolet irradiation. Self-cleaning property of cotton fabric coated with TiO{sub 2} was evaluated with color depth of samples (K/S value). The treated fabrics were characterized using scanning electron microscopy (SEM), energy dispersive spectrometer (EDS), Fourier transform infrared spectroscopy (FITR), tensile strength, stiffness and whiteness. The results indicated, TiO{sub 2} nanoparticles could be embedded on the surface layer of cotton fabrics throuth surface micro-dissolve method. Treated cotton fabrics possessed distinct photocatalytic efficiency and self-cleaning properties. Tensile strength and whiteness of modified cotton fabrics appeared moderately increasement.

  19. Micro- and nanoscale phenomena in tribology

    CERN Document Server

    Chung, Yip-Wah

    2011-01-01

    Drawn from presentations at a recent National Science Foundation Summer Institute on Nanomechanics, Nanomaterials, and Micro/Nanomanufacturing, Micro- and Nanoscale Phenomena in Tribology explores the convergence of the multiple science and engineering disciplines involved in tribology and the connection from the macro to nano world. Written by specialists from computation, materials science, mechanical engineering, surface physics, and chemistry, each chapter provides up-to-date coverage of both basic and advanced topics and includes extensive references for further study.After discussing the

  20. Evaluation of thermal aging effect on primary pipe material in nuclear power plant by micro hardness test method

    International Nuclear Information System (INIS)

    Xue Fei; Yu Weiwei; Wang Zhaoxi; Ma Qinzheng; Liu Wei

    2012-01-01

    The investigation was carried out on the changes in mechanical properties of the primary pipe material Z3CN20.09M after 10000 h aging at 400℃ by using micro- Vickers and impact testing machine. The results show that the impact energy of testing material decreases. However, the micro-Vickers hardness of ferrite phase and austenite phase which constitute the testing material increase and keep constant, respectively. The intrinsic relations were analyzed between the micro-Vickers hardness and the impact energy to make an attempt to present the micro-Vickers hardness measurement as a method applicable to evaluating the thermal aging of the primary pipe material. (authors)

  1. An integrated approach to permeability modeling using micro-models

    Energy Technology Data Exchange (ETDEWEB)

    Hosseini, A.H.; Leuangthong, O.; Deutsch, C.V. [Society of Petroleum Engineers, Canadian Section, Calgary, AB (Canada)]|[Alberta Univ., Edmonton, AB (Canada)

    2008-10-15

    An important factor in predicting the performance of steam assisted gravity drainage (SAGD) well pairs is the spatial distribution of permeability. Complications that make the inference of a reliable porosity-permeability relationship impossible include the presence of short-scale variability in sand/shale sequences; preferential sampling of core data; and uncertainty in upscaling parameters. Micro-modelling is a simple and effective method for overcoming these complications. This paper proposed a micro-modeling approach to account for sampling bias, small laminated features with high permeability contrast, and uncertainty in upscaling parameters. The paper described the steps and challenges of micro-modeling and discussed the construction of binary mixture geo-blocks; flow simulation and upscaling; extended power law formalism (EPLF); and the application of micro-modeling and EPLF. An extended power-law formalism to account for changes in clean sand permeability as a function of macroscopic shale content was also proposed and tested against flow simulation results. There was close agreement between the model and simulation results. The proposed methodology was also applied to build the porosity-permeability relationship for laminated and brecciated facies of McMurray oil sands. Experimental data was in good agreement with the experimental data. 8 refs., 17 figs.

  2. Air Monitoring: New Advances in Sampling and Detection

    Directory of Open Access Journals (Sweden)

    Nicola Watson

    2011-01-01

    Full Text Available As the harmful effects of low-level exposure to hazardous organic air pollutants become more evident, there is constant pressure to improve the detection limits of indoor and ambient air monitoring methods, for example, by collecting larger air volumes and by optimising the sensitivity of the analytical detector. However, at the other end of the scale, rapid industrialisation in the developing world and growing pressure to reclaim derelict industrial land for house building is driving the need for air monitoring methods that can reliably accommodate very-high-concentration samples in potentially aggressive matrices. This paper investigates the potential of a combination of two powerful gas chromatography—based analytical enhancements—sample preconcentration/thermal desorption and time-of-flight mass spectrometry—to improve quantitative and qualitative measurement of very-low-(ppt level organic chemicals, even in the most complex air samples. It also describes new, practical monitoring options for addressing equally challenging high-concentration industrial samples.

  3. MicroRNA signature of the human developing pancreas

    Directory of Open Access Journals (Sweden)

    Correa-Medina Mayrin

    2010-09-01

    Full Text Available Abstract Background MicroRNAs are non-coding RNAs that regulate gene expression including differentiation and development by either inhibiting translation or inducing target degradation. The aim of this study is to determine the microRNA expression signature during human pancreatic development and to identify potential microRNA gene targets calculating correlations between the signature microRNAs and their corresponding mRNA targets, predicted by bioinformatics, in genome-wide RNA microarray study. Results The microRNA signature of human fetal pancreatic samples 10-22 weeks of gestational age (wga, was obtained by PCR-based high throughput screening with Taqman Low Density Arrays. This method led to identification of 212 microRNAs. The microRNAs were classified in 3 groups: Group number I contains 4 microRNAs with the increasing profile; II, 35 microRNAs with decreasing profile and III with 173 microRNAs, which remain unchanged. We calculated Pearson correlations between the expression profile of microRNAs and target mRNAs, predicted by TargetScan 5.1 and miRBase altgorithms, using genome-wide mRNA expression data. Group I correlated with the decreasing expression of 142 target mRNAs and Group II with the increasing expression of 876 target mRNAs. Most microRNAs correlate with multiple targets, just as mRNAs are targeted by multiple microRNAs. Among the identified targets are the genes and transcription factors known to play an essential role in pancreatic development. Conclusions We have determined specific groups of microRNAs in human fetal pancreas that change the degree of their expression throughout the development. A negative correlative analysis suggests an intertwined network of microRNAs and mRNAs collaborating with each other. This study provides information leading to potential two-way level of combinatorial control regulating gene expression through microRNAs targeting multiple mRNAs and, conversely, target mRNAs regulated in

  4. MicroRNA-target binding structures mimic microRNA duplex structures in humans.

    Directory of Open Access Journals (Sweden)

    Xi Chen

    Full Text Available Traditionally, researchers match a microRNA guide strand to mRNA sequences using sequence comparisons to predict its potential target genes. However, many of the predictions can be false positives due to limitations in sequence comparison alone. In this work, we consider the association of two related RNA structures that share a common guide strand: the microRNA duplex and the microRNA-target binding structure. We have analyzed thousands of such structure pairs and found many of them share high structural similarity. Therefore, we conclude that when predicting microRNA target genes, considering just the microRNA guide strand matches to gene sequences may not be sufficient--the microRNA duplex structure formed by the guide strand and its companion passenger strand must also be considered. We have developed software to translate RNA binding structure into encoded representations, and we have also created novel automatic comparison methods utilizing such encoded representations to determine RNA structure similarity. Our software and methods can be utilized in the other RNA secondary structure comparisons as well.

  5. The dynamic micro computed tomography at SSRF

    Science.gov (United States)

    Chen, R.; Xu, L.; Du, G.; Deng, B.; Xie, H.; Xiao, T.

    2018-05-01

    Synchrotron radiation micro-computed tomography (SR-μCT) is a critical technique for quantitative characterizing the 3D internal structure of samples, recently the dynamic SR-μCT has been attracting vast attention since it can evaluate the three-dimensional structure evolution of a sample. A dynamic μCT method, which is based on monochromatic beam, was developed at the X-ray Imaging and Biomedical Application Beamline at Shanghai Synchrotron Radiation Facility, by combining the compressed sensing based CT reconstruction algorithm and hardware upgrade. The monochromatic beam based method can achieve quantitative information, and lower dose than the white beam base method in which the lower energy beam is absorbed by the sample rather than contribute to the final imaging signal. The developed method is successfully used to investigate the compression of the air sac during respiration in a bell cricket, providing new knowledge for further research on the insect respiratory system.

  6. Micro tooling technologies for polymer micro replication: direct, indirect and hybrid process chains

    DEFF Research Database (Denmark)

    Tosello, Guido; Hansen, Hans Nørgaard

    2009-01-01

    The increasing employment of micro products, of products containing micro parts and of products with micro-structured surfaces calls for mass fabrication technologies based on replication processes. In many cases, a suitable solution is given by the use of polymer micro products, whose production...... and performance of the corresponding micro mould. Traditional methods of micro tooling, such as various machining processes (e.g. micro milling, micro electrical discharge machining) have already reached their limitations with decreasing dimensions of mould inserts and cavities. To this respect, tooling process...... chains based on combination of micro manufacturing processes (defined as hybrid tooling) have been established in order to obtain further features miniaturization and increased accuracy. In this paper, examples and performance of different hybrid tooling approaches as well as challenges, opportunities...

  7. 7 CFR 29.110 - Method of sampling.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Method of sampling. 29.110 Section 29.110 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... INSPECTION Regulations Inspectors, Samplers, and Weighers § 29.110 Method of sampling. In sampling tobacco...

  8. Uniform Sampling Table Method and its Applications II--Evaluating the Uniform Sampling by Experiment.

    Science.gov (United States)

    Chen, Yibin; Chen, Jiaxi; Chen, Xuan; Wang, Min; Wang, Wei

    2015-01-01

    A new method of uniform sampling is evaluated in this paper. The items and indexes were adopted to evaluate the rationality of the uniform sampling. The evaluation items included convenience of operation, uniformity of sampling site distribution, and accuracy and precision of measured results. The evaluation indexes included operational complexity, occupation rate of sampling site in a row and column, relative accuracy of pill weight, and relative deviation of pill weight. They were obtained from three kinds of drugs with different shape and size by four kinds of sampling methods. Gray correlation analysis was adopted to make the comprehensive evaluation by comparing it with the standard method. The experimental results showed that the convenience of uniform sampling method was 1 (100%), odds ratio of occupation rate in a row and column was infinity, relative accuracy was 99.50-99.89%, reproducibility RSD was 0.45-0.89%, and weighted incidence degree exceeded the standard method. Hence, the uniform sampling method was easy to operate, and the selected samples were distributed uniformly. The experimental results demonstrated that the uniform sampling method has good accuracy and reproducibility, which can be put into use in drugs analysis.

  9. Symptoms and problems in a nationally representative sample of advanced cancer patients

    DEFF Research Database (Denmark)

    Johnsen, Anna Thit; Petersen, Morten Aagaard; Pedersen, Lise

    2009-01-01

    Little is known about the need for palliative care among advanced cancer patients who are not in specialist palliative care. The purpose was to identify prevalence and predictors of symptoms and problems in a nationally representative sample of Danish advanced cancer patients. Patients with cancer...... or not were associated with several symptoms and problems. This is probably the first nationally representative study of its kind. It shows that advanced cancer patients in Denmark have symptoms and problems that deserve attention and that some patient groups are especially at risk....... predictors. In total, 977 (60%) patients participated. The most frequent symptoms/problems were fatigue (57%; severe 22%) followed by reduced role function, insomnia and pain. Age, cancer stage, primary tumour, type of department, marital status and whether the patient had recently been hospitalized...

  10. A Micro-Cylindrical Ion Trap (µ-CIT) Micro-Mass Spectrometer Instrument System (µ-MSIS) for NASA Planetary Exploration

    Data.gov (United States)

    National Aeronautics and Space Administration — The goal of this follow-on early stage innovation activity is to advance the development of new, extremely small, low power, and low cost "micro" mass spectrometer...

  11. Sample pretretment in microsystems

    DEFF Research Database (Denmark)

    Perch-Nielsen, Ivan R.

    2003-01-01

    : Sample preparation → DNA amplification → DNA analysis. The overall goal of the project is integration of as many as possible of these steps. This thesis covers mainly pretreatment in a microchip. Some methods for sample pretreatment have been tested. Most conventional is fluorescence activated cell sort......When a sample, e.g. from a patient, is processed using conventional methods, the sample must be transported to the laboratory where it is analyzed, after which the results is sent back. By integrating the separate steps of the analysis in a micro total analysis system (μTAS), results can...... be obtained fast and better. Preferably with all the processes from sample to signal moved to the bedside of the patient. Of course there is still much to learn and study in the process of miniaturization. DNA analysis is one process subject to integration. There are roughly three steps in a DNA analysis...

  12. Determination of rare earth elements in natural water samples – A review of sample separation, preconcentration and direct methodologies

    Energy Technology Data Exchange (ETDEWEB)

    Fisher, Andrew, E-mail: afisher@plymouth.ac.uk [School of Geography, Earth and Environmental Sciences, Plymouth University, Drake Circus, Plymouth, Devon, PL4 8AA (United Kingdom); Kara, Derya [Department of Chemistry, Art and Science Faculty, Balikesir University, 10100, Balikesir (Turkey)

    2016-09-07

    This review discusses and compares the methods given for the determination of rare earth elements (REE) in natural water samples, including sea, river, lake, tap, ground and waste waters as well as Antarctic ice. Since REE are at very low concentrations in natural waters, numerous different preconcentration methods have been proposed to enable their measurement. These include liquid liquid extraction, dispersive liquid-liquid micro-extraction and solidified floating drop micro-extraction. In addition to liquid-liquid extraction methods, solid phase extraction using commercial resins, resins made in-house, silica-based exchange materials and other solid media is also discussed. These and other techniques such as precipitation/co-precipitation and flotation are compared in terms of speed, preconcentration factors achieved, precision, accuracy and limits of detection (LOD). Some papers have discussed the direct determination of REE in these sample types. Some have used specialised sample introduction systems such as ultrasonic nebulization whereas others have used a standard sample introduction system coupled with inductively coupled plasma mass spectrometry (ICP-MS) detection. These direct methods have also been discussed and compared. - Highlights: • The determination of rare earth elements in waters is reviewed. • Assorted preconcentration techniques are discussed and evaluated. • Detection techniques include atomic spectrometry, potentiometry and spectrophotometry. • Special nebulisers and electrothermal vaporization approaches are reviewed.

  13. Characteristics of UV-MicroO3 Reactor and Its Application to Microcystins Degradation during Surface Water Treatment

    Directory of Open Access Journals (Sweden)

    Guangcan Zhu

    2015-01-01

    Full Text Available The UV-ozone (UV-O3 process is not widely applied in wastewater and potable water treatment partly for the relatively high cost since complicated UV radiation and ozone generating systems are utilized. The UV-microozone (UV-microO3, a new advanced process that can solve the abovementioned problems, was introduced in this study. The effects of air flux, air pressure, and air humidity on generation and concentration of O3 in UV-microO3 reactor were investigated. The utilization of this UV-microO3 reactor in microcystins (MCs degradation was also carried out. Experimental results indicated that the optimum air flux in the reactor equipped with 37 mm diameter quartz tube was determined to be 18∼25 L/h for efficient O3 generation. The air pressure and humidity in UV-microO3 reactor should be low enough in order to get optimum O3 output. Moreover, microcystin-RR, YR, and LR (MC-RR, MC-YR, and MC-LR could be degraded effectively by UV-microO3 process. The degradation of different MCs was characterized by first-order reaction kinetics. The pseudofirst-order kinetic constants for MC-RR, MC-YR, and MC-LR degradation were 0.0093, 0.0215, and 0.0286 min−1, respectively. Glucose had no influence on MC degradation through UV-microO3. The UV-microO3 process is hence recommended as a suitable advanced treatment method for dissolved MCs degradation.

  14. Fabrication and Application of Mono-sized Spherical Micro Particles by Pulsated Orifice Ejection Method

    Directory of Open Access Journals (Sweden)

    DONG Wei

    2018-02-01

    Full Text Available A novel technology called pulsated orifice ejection method(POEM and used for preparing mono-sized and high-precision spherical micro particles was introduced in this article. The working principle of the technique was illustrated and it was in two modes:low-melting point diaphragm mode and high-melting point rod mode, depending on the different melting points of materials. The particles prepared by POEM have the advantages of mono-sized, uniform and controllable particle size, high sphericity, and consistent thermal history. By introducing the application of particles prepared by this method, showing the huge application prospects of this technology in electronic packaging, bioengineering, micro-fabrication, rapid solidification analysis of metal droplets, additive manufacturing and so on.With the development of POEM, this technology is predicted to have wider prospects due to its unique characteristics.

  15. Error baseline rates of five sample preparation methods used to characterize RNA virus populations.

    Directory of Open Access Journals (Sweden)

    Jeffrey R Kugelman

    Full Text Available Individual RNA viruses typically occur as populations of genomes that differ slightly from each other due to mutations introduced by the error-prone viral polymerase. Understanding the variability of RNA virus genome populations is critical for understanding virus evolution because individual mutant genomes may gain evolutionary selective advantages and give rise to dominant subpopulations, possibly even leading to the emergence of viruses resistant to medical countermeasures. Reverse transcription of virus genome populations followed by next-generation sequencing is the only available method to characterize variation for RNA viruses. However, both steps may lead to the introduction of artificial mutations, thereby skewing the data. To better understand how such errors are introduced during sample preparation, we determined and compared error baseline rates of five different sample preparation methods by analyzing in vitro transcribed Ebola virus RNA from an artificial plasmid-based system. These methods included: shotgun sequencing from plasmid DNA or in vitro transcribed RNA as a basic "no amplification" method, amplicon sequencing from the plasmid DNA or in vitro transcribed RNA as a "targeted" amplification method, sequence-independent single-primer amplification (SISPA as a "random" amplification method, rolling circle reverse transcription sequencing (CirSeq as an advanced "no amplification" method, and Illumina TruSeq RNA Access as a "targeted" enrichment method. The measured error frequencies indicate that RNA Access offers the best tradeoff between sensitivity and sample preparation error (1.4-5 of all compared methods.

  16. Error baseline rates of five sample preparation methods used to characterize RNA virus populations

    Science.gov (United States)

    Kugelman, Jeffrey R.; Wiley, Michael R.; Nagle, Elyse R.; Reyes, Daniel; Pfeffer, Brad P.; Kuhn, Jens H.; Sanchez-Lockhart, Mariano; Palacios, Gustavo F.

    2017-01-01

    Individual RNA viruses typically occur as populations of genomes that differ slightly from each other due to mutations introduced by the error-prone viral polymerase. Understanding the variability of RNA virus genome populations is critical for understanding virus evolution because individual mutant genomes may gain evolutionary selective advantages and give rise to dominant subpopulations, possibly even leading to the emergence of viruses resistant to medical countermeasures. Reverse transcription of virus genome populations followed by next-generation sequencing is the only available method to characterize variation for RNA viruses. However, both steps may lead to the introduction of artificial mutations, thereby skewing the data. To better understand how such errors are introduced during sample preparation, we determined and compared error baseline rates of five different sample preparation methods by analyzing in vitro transcribed Ebola virus RNA from an artificial plasmid-based system. These methods included: shotgun sequencing from plasmid DNA or in vitro transcribed RNA as a basic “no amplification” method, amplicon sequencing from the plasmid DNA or in vitro transcribed RNA as a “targeted” amplification method, sequence-independent single-primer amplification (SISPA) as a “random” amplification method, rolling circle reverse transcription sequencing (CirSeq) as an advanced “no amplification” method, and Illumina TruSeq RNA Access as a “targeted” enrichment method. The measured error frequencies indicate that RNA Access offers the best tradeoff between sensitivity and sample preparation error (1.4−5) of all compared methods. PMID:28182717

  17. A micro-flow-batch analyzer with solenoid micro-pumps for the photometric determination of iodate in table salt.

    Science.gov (United States)

    Lima, Marcelo B; Barreto, Inakã S; Andrade, Stéfani Iury E; Almeida, Luciano F; Araújo, Mário C U

    2012-10-15

    In this study, a micro-flow-batch analyzer (μFBA) with solenoid micro-pumps for the photometric determination of iodate in table salt is described. The method is based on the reaction of iodate with iodide to form molecular iodine followed by the reaction with N,N-diethyl-p-phenylenediamine (DPD). The analytical signal was measured at 520 nm using a green LED integrated into the μFBA built in the urethane-acrylate resin. The analytical curve for iodate was linear in the range of 0.01-10.0 mg L(-1) with a correlation coefficient of 0.997. The limit of detection and relative standard deviation were estimated at 0.004 mg L(-1) and<1.5% (n=3), respectively. The accuracy was assessed through recovery test (97.6-103.5%) and independent analysis by a conventional titrimetric method. Comparing this technique with the conventional method, no statistically significant differences were observed when applying the paired t-test at a 95% confidence level. The proposed microsystem using solenoid micro-pumps presented satisfactory robustness and high sampling rate (170 h(-1)), with a low reagents consumption and a low cost to build the device. The proposed microsystem is a new alternative for automatic determination of iodate in table salt, comparing satisfactory to the recently flow system. Copyright © 2012 Elsevier B.V. All rights reserved.

  18. Micro-plastic ingestion by waterbirds from contaminated wetlands in South Africa.

    Science.gov (United States)

    Reynolds, Chevonne; Ryan, Peter G

    2018-01-01

    Despite a large literature on the impacts of micro-plastic pollution in marine ecosystems, very little research has focused on these pollutants in freshwater ecosystems. Recently, however, a few studies have demonstrated that micro-plastic pollutants are ingested by freshwater taxa, including birds. To explore this potential environmental threat in African freshwater systems we quantified micro-plastic pollutants in the faeces and feather brushings of seven southern African duck species. We analysed 283 faecal samples and 408 feather brushings, and found that 5% of faecal samples and 10% of feather samples contained micro-plastic fibres. The presence and abundance of micro-fibres differed between sampling sites, with significantly higher amounts recorded for the site that received effluent from a sewage treatment facility. Additionally, micro-fibre presence differed across duck species, indicating that foraging behaviour affects plastic ingestion. Our study confirms that African freshwater ecosystems and the biodiversity they support are under threat from micro-plastic contamination. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Weathering Patterns of Ignitable Liquids with the Advanced Distillation Curve Method.

    Science.gov (United States)

    Bruno, Thomas J; Allen, Samuel

    2013-01-01

    One can take advantage of the striking similarity of ignitable liquid vaporization (or weathering) patterns and the separation observed during distillation to predict the composition of residual compounds in fire debris. This is done with the advanced distillation curve (ADC) metrology, which separates a complex fluid by distillation into fractions that are sampled, and for which thermodynamically consistent temperatures are measured at atmospheric pressure. The collected sample fractions can be analyzed by any method that is appropriate. Analytical methods we have applied include gas chromatography (with flame ionization, mass spectrometric and sulfur chemiluminescence detection), thin layer chromatography, FTIR, Karl Fischer coulombic titrimetry, refractometry, corrosivity analysis, neutron activation analysis and cold neutron prompt gamma activation analysis. We have applied this method on product streams such as finished fuels (gasoline, diesel fuels, aviation fuels, rocket propellants), crude oils (including a crude oil made from swine manure) and waste oils streams (used automotive and transformer oils). In this paper, we present results on a variety of ignitable liquids that are not commodity fuels, chosen from the Ignitable Liquids Reference Collection (ILRC). These measurements are assembled into a preliminary database. From this selection, we discuss the significance and forensic application of the temperature data grid and the composition explicit data channel of the ADC.

  20. Weathering Patterns of Ignitable Liquids with the Advanced Distillation Curve Method

    Science.gov (United States)

    Bruno, Thomas J; Allen, Samuel

    2013-01-01

    One can take advantage of the striking similarity of ignitable liquid vaporization (or weathering) patterns and the separation observed during distillation to predict the composition of residual compounds in fire debris. This is done with the advanced distillation curve (ADC) metrology, which separates a complex fluid by distillation into fractions that are sampled, and for which thermodynamically consistent temperatures are measured at atmospheric pressure. The collected sample fractions can be analyzed by any method that is appropriate. Analytical methods we have applied include gas chromatography (with flame ionization, mass spectrometric and sulfur chemiluminescence detection), thin layer chromatography, FTIR, Karl Fischer coulombic titrimetry, refractometry, corrosivity analysis, neutron activation analysis and cold neutron prompt gamma activation analysis. We have applied this method on product streams such as finished fuels (gasoline, diesel fuels, aviation fuels, rocket propellants), crude oils (including a crude oil made from swine manure) and waste oils streams (used automotive and transformer oils). In this paper, we present results on a variety of ignitable liquids that are not commodity fuels, chosen from the Ignitable Liquids Reference Collection (ILRC). These measurements are assembled into a preliminary database. From this selection, we discuss the significance and forensic application of the temperature data grid and the composition explicit data channel of the ADC. PMID:26401423

  1. Modeling and simulation for micro DC motor based on simulink

    Science.gov (United States)

    Shen, Hanxin; Lei, Qiao; Chen, Wenxiang

    2017-09-01

    The micro DC motor has a large market demand but there is a lack of theoretical research for it. Through detailed analysis of the commutation process of micro DC motor commutator, based on micro DC motor electromagnetic torque equation and mechanical torque equation, with the help of Simulink toolkit, a triangle connection micro DC motor simulation model is established. By using the model, a sample micro DC motor are simulated, and an experimental measurements has been carried on the sample micro DC motor. It is found that the simulation results are consistent with theoretical analysis and experimental results.

  2. A simple, rapid, cost-effective and sensitive method for detection of Salmonella in environmental and pecan samples.

    Science.gov (United States)

    Dobhal, S; Zhang, G; Rohla, C; Smith, M W; Ma, L M

    2014-10-01

    PCR is widely used in the routine detection of foodborne human pathogens; however, challenges remain in overcoming PCR inhibitors present in some sample matrices. The objective of this study was to develop a simple, sensitive, cost-effective and rapid method for processing large numbers of environmental and pecan samples for Salmonella detection. This study was also aimed at validation of a new protocol for the detection of Salmonella from in-shell pecans. Different DNA template preparation methods, including direct boiling, prespin, multiple washing and commercial DNA extraction kits, were evaluated with pure cultures of Salmonella Typhimurium and with enriched soil, cattle feces and in-shell pecan each spiked individually with Salmonella Typhimurium. PCR detection of Salmonella was conducted using invA and 16S rRNA gene (internal amplification control) specific primers. The effect of amplification facilitators, including bovine serum albumin (BSA), polyvinylpyrrolidone (PVP), polyethylene glycol (PEG) and gelatin on PCR sensitivity, was also evaluated. Conducting a prespin of sample matrices in combination with the addition of 0·4% (w/v) BSA and 1% (w/v) PVP in PCR mix was the simplest, most rapid, cost-effective and sensitive method for PCR detection of Salmonella, with up to 40 CFU Salmonella per reaction detectable in the presence of over 10(9 ) CFU ml(-1) of background micro-organisms from enriched feces soil or pecan samples. The developed method is rapid, cost-effective and sensitive for detection of Salmonella from different matrices. This study provides a method with broad applicability for PCR detection of Salmonella in complex sample matrices. This method has a potential for its application in different research arenas and diagnostic laboratories. © 2014 The Society for Applied Microbiology.

  3. Mathematics for natural scientists II advanced methods

    CERN Document Server

    Kantorovich, Lev

    2016-01-01

    This book covers the advanced mathematical techniques useful for physics and engineering students, presented in a form accessible to physics students, avoiding precise mathematical jargon and laborious proofs. Instead, all proofs are given in a simplified form that is clear and convincing for a physicist. Examples, where appropriate, are given from physics contexts. Both solved and unsolved problems are provided in each chapter. Mathematics for Natural Scientists II: Advanced Methods is the second of two volumes. It follows the first volume on Fundamentals and Basics.

  4. 19 CFR 151.83 - Method of sampling.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 2 2010-04-01 2010-04-01 false Method of sampling. 151.83 Section 151.83 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY (CONTINUED) EXAMINATION, SAMPLING, AND TESTING OF MERCHANDISE Cotton § 151.83 Method of sampling. For...

  5. Micro-organism distribution sampling for bioassays

    Science.gov (United States)

    Nelson, B. A.

    1975-01-01

    Purpose of sampling distribution is to characterize sample-to-sample variation so statistical tests may be applied, to estimate error due to sampling (confidence limits) and to evaluate observed differences between samples. Distribution could be used for bioassays taken in hospitals, breweries, food-processing plants, and pharmaceutical plants.

  6. ALARA ASSESSMENT OF SETTLER SLUDGE SAMPLING METHODS

    International Nuclear Information System (INIS)

    Nelsen, L.A.

    2009-01-01

    The purpose of this assessment is to compare underwater and above water settler sludge sampling methods to determine if the added cost for underwater sampling for the sole purpose of worker dose reductions is justified. Initial planning for sludge sampling included container, settler and knock-out-pot (KOP) sampling. Due to the significantly higher dose consequence of KOP sludge, a decision was made to sample KOP underwater to achieve worker dose reductions. Additionally, initial plans were to utilize the underwater sampling apparatus for settler sludge. Since there are no longer plans to sample KOP sludge, the decision for underwater sampling for settler sludge needs to be revisited. The present sampling plan calls for spending an estimated $2,500,000 to design and construct a new underwater sampling system (per A21 C-PL-001 RevOE). This evaluation will compare and contrast the present method of above water sampling to the underwater method that is planned by the Sludge Treatment Project (STP) and determine if settler samples can be taken using the existing sampling cart (with potentially minor modifications) while maintaining doses to workers As Low As Reasonably Achievable (ALARA) and eliminate the need for costly redesigns, testing and personnel retraining

  7. ALARA ASSESSMENT OF SETTLER SLUDGE SAMPLING METHODS

    Energy Technology Data Exchange (ETDEWEB)

    NELSEN LA

    2009-01-30

    The purpose of this assessment is to compare underwater and above water settler sludge sampling methods to determine if the added cost for underwater sampling for the sole purpose of worker dose reductions is justified. Initial planning for sludge sampling included container, settler and knock-out-pot (KOP) sampling. Due to the significantly higher dose consequence of KOP sludge, a decision was made to sample KOP underwater to achieve worker dose reductions. Additionally, initial plans were to utilize the underwater sampling apparatus for settler sludge. Since there are no longer plans to sample KOP sludge, the decision for underwater sampling for settler sludge needs to be revisited. The present sampling plan calls for spending an estimated $2,500,000 to design and construct a new underwater sampling system (per A21 C-PL-001 RevOE). This evaluation will compare and contrast the present method of above water sampling to the underwater method that is planned by the Sludge Treatment Project (STP) and determine if settler samples can be taken using the existing sampling cart (with potentially minor modifications) while maintaining doses to workers As Low As Reasonably Achievable (ALARA) and eliminate the need for costly redesigns, testing and personnel retraining.

  8. MicroRNA Expression in Early Mycosis Fungoides Is Distinctly Different from Atopic Dermatitis and Advanced Cutaneous T-Cell Lymphoma

    DEFF Research Database (Denmark)

    Ralfkiaer, Ulrik; Lindahl, Lise Maria; Litman, Thomas

    2014-01-01

    Mycosis fungoides (MF) is the most common variant of cutaneous T-cell lymphoma (CTCL). MF is characterized by chronic inflammation dominated by cluster of differentiation 4-positive (CD4(+)) T-cells and T helper 2 cytokines, and as the malignant T-cell clone is initially elusive, early diagnosis...... is often impossible. MF usually takes an indolent course, but for unknown reasons may turn into an aggressive disease with a poor prognosis. Herein, we used a global quantitative real-time polymerase chain reaction platform to study microRNA (miR) expression in patients with early MF (n=13), more advanced...... CTCL (n=42), and atopic dermatitis (AD, n=20). Thirty-eight miRs were differentially expressed (≥2-fold) in early MF vs. AD and 36 in early MF vs. more advanced disease. miRs that distinguish early MF from AD included both up-regulated (miR-155, miR-146a, 146b-5p, miR-342-3p, let-7i*) and down...

  9. Optimization and analysis of a quantitative real-time PCR-based technique to determine microRNA expression in formalin-fixed paraffin-embedded samples

    Directory of Open Access Journals (Sweden)

    Reis Patricia P

    2010-06-01

    Full Text Available Abstract Background MicroRNAs (miRs are non-coding RNA molecules involved in post-transcriptional regulation, with diverse functions in tissue development, differentiation, cell proliferation and apoptosis. miRs may be less prone to degradation during formalin fixation, facilitating miR expression studies in formalin-fixed paraffin-embedded (FFPE tissue. Results Our study demonstrates that the TaqMan Human MicroRNA Array v1.0 (Early Access platform is suitable for miR expression analysis in FFPE tissue with a high reproducibility (correlation coefficients of 0.95 between duplicates, p 35, we show that reproducibility between technical replicates, equivalent dilutions, and FFPE vs. frozen samples is best in the high abundance stratum. We also demonstrate that the miR expression profiles of FFPE samples are comparable to those of fresh-frozen samples, with a correlation of up to 0.87 (p Conclusion Our study thus demonstrates the utility, reproducibility, and optimization steps needed in miR expression studies using FFPE samples on a high-throughput quantitative PCR-based miR platform, opening up a realm of research possibilities for retrospective studies.

  10. SCHEME (Soft Control Human error Evaluation MEthod) for advanced MCR HRA

    International Nuclear Information System (INIS)

    Jang, Inseok; Jung, Wondea; Seong, Poong Hyun

    2015-01-01

    The Technique for Human Error Rate Prediction (THERP), Korean Human Reliability Analysis (K-HRA), Human Error Assessment and Reduction Technique (HEART), A Technique for Human Event Analysis (ATHEANA), Cognitive Reliability and Error Analysis Method (CREAM), and Simplified Plant Analysis Risk Human Reliability Assessment (SPAR-H) in relation to NPP maintenance and operation. Most of these methods were developed considering the conventional type of Main Control Rooms (MCRs). They are still used for HRA in advanced MCRs even though the operating environment of advanced MCRs in NPPs has been considerably changed by the adoption of new human-system interfaces such as computer-based soft controls. Among the many features in advanced MCRs, soft controls are an important feature because the operation action in NPP advanced MCRs is performed by soft controls. Consequently, those conventional methods may not sufficiently consider the features of soft control execution human errors. To this end, a new framework of a HRA method for evaluating soft control execution human error is suggested by performing the soft control task analysis and the literature reviews regarding widely accepted human error taxonomies. In this study, the framework of a HRA method for evaluating soft control execution human error in advanced MCRs is developed. First, the factors which HRA method in advanced MCRs should encompass are derived based on the literature review, and soft control task analysis. Based on the derived factors, execution HRA framework in advanced MCRs is developed mainly focusing on the features of soft control. Moreover, since most current HRA database deal with operation in conventional type of MCRs and are not explicitly designed to deal with digital HSI, HRA database are developed under lab scale simulation

  11. Development and validation of reversed-phase high performance liquid chromatographic method for analysis of cephradine in human plasma samples

    International Nuclear Information System (INIS)

    Ahmad, M.; Usman, M.; Madni, A.; Akhtar, N.; Khalid, N.; Asghar, W.

    2010-01-01

    An HPLC method with high precision, accuracy and selectivity was developed and validated for the assessment of cephradine in human plasma samples. The extraction procedure was simple and accurate with single step followed by direct injection of sample into HPLC system. The extracted cephradine in spiked human plasma was separated and quantitated using reversed phase C/sub 18/ column and UV detection wavelength of 254 nm. The optimized mobile phase of new composition of 0.05 M potassium dihydrogen phosphate (pH 3.4)-acetonitrile (88: 12) was pumped at an optimum flow rate of 1 mL.min/sup 1/. The method resulted linearity in the concentration range 0.15- 20 micro g mL/sup -1/. The limit of detection (LOD) and limit of quantification (LOQ) were 0.05 and 0.150 Microg.mL/sup -1/, respectively. The accuracy of method was 98.68 %. This method can 1>e applied for bioequivalence studies and therapeutic drug monitoring as well as for the routine analysis of cephradine. (author)

  12. Micro-CT of Carotid Arteries: A Tool for Experimental Studies

    International Nuclear Information System (INIS)

    Mohr, Andreas; Wenke, Ruediger; Roemer, Frank W.; Lynch, John A.; Gatzka, Christian; Priebe, Markus; Guermazi, Ali; Grigorian, Mikayel; Heller, Martin; Mueller-Huelsbeck, Stefan

    2004-01-01

    Micro-computed tomography (micro-CT) is a high-resolution, nondestructive tool for two- and three-dimensional imaging and quantification. The ability of this technique to assess atherosclerosis of the carotid artery was evaluated in three human cadaver samples based on the original axial acquisitions, multiplanar reconstructions and volume rendering techniques. Quantitative analysis included the calculation of: (1) the original lumen perimeter, original lumen area, plaque area, residual lumen area, calcified area and gross sectional area reduction of the vascular lumen from two-dimensional slices; (2) the total tissue volume, soft tissue volume and calcified tissue volume from the three-dimensional data set. This preliminary study demonstrates the potential of micro-CT as a supplementary method for the two- and three-dimensional ex vivo evaluation of carotid atherosclerosis

  13. A Simplified Control Method for Tie-Line Power of DC Micro-Grid

    OpenAIRE

    Yanbo Che; Jinhuan Zhou; Tingjun Lin; Wenxun Li; Jianmei Xu

    2018-01-01

    Compared with the AC micro-grid, the DC micro-grid has low energy loss and no issues of frequency stability, which makes it more accessible for distributed energy. Thus, the DC micro-grid has good potential for development. A variety of renewable energy is included in the DC micro-grid, which is easily affected by the environment, causing fluctuation of the DC voltage. For grid-connected DC micro-grid with droop control strategy, the tie-line power is affected by fluctuations in the DC voltag...

  14. A novel method to predict the highest hardness of plasma sprayed coating without micro-defects

    Science.gov (United States)

    Zhuo, Yukun; Ye, Fuxing; Wang, Feng

    2018-04-01

    The plasma sprayed coatings are stacked by splats, which are regarded generally as the elementary units of coating. Many researchers have focused on the morphology and formation mechanism of splat. However, a novel method to predict the highest hardness of plasma sprayed coating without micro-defects is proposed according to the nanohardness of splat in this paper. The effectiveness of this novel method was examined by experiments. Firstly, the microstructure of splats and coating, meanwhile the 3D topography of the splats were observed by SEM (SU1510) and video microscope (VHX-2000). Secondly, the nanohardness of splats was evaluated by nanoindentation (NHT) in order to be compared with microhardness of coating measured by microhardness tester (HV-1000A). The results show that the nanohardness of splats with diameter of 70 μm, 100 μm and 140 μm were in the scope of 11∼12 GPa while the microhardness of coating were in the range of 8∼9 GPa. Because the splats had not micro-defects such as pores and cracks in the nanohardness evaluated nano-zone, the nanohardness of the splats can be utilized to predict the highest hardness of coating without micro-defects. This method indicates the maximum of sprayed coating hardness and will reduce the test number to get high hardness coating for better wear resistance.

  15. Meissner-levitated micro-systems

    Energy Technology Data Exchange (ETDEWEB)

    Coombs, T A; Samad, I; Hong, Z; Eves, D; Rastogi, A [Cambridge University Engineering Department, Trumpington Street, Cambridge, CB2 PZ (United Kingdom)

    2006-06-01

    Advanced silicon processing techniques developed for the Very Large Scale Integration (VLSI) industry have been exploited in recent years to enable the production of micro-fabricated moving mechanical systems known as Micro Electro Mechanical Systems (MEMS). These devices offer advantages in terms of cost, scalability and robustness over their preceding equivalents. Cambridge University have worked for many years on the investigation of high temperature superconductors (HTS) in flywheel energy storage applications. This experience is now being used to research into superconducting Micro-Bearings for MEMS, whereby circular permanent magnet arrays are levitated and spun above a superconductor to produce bearings suitable for motors and other micron scale devices. The novelty in the device lies in the fact that the rotor is levitated into position by Meissner flux exclusion, whilst stability is provided by flux pinned within the body of the superconductor. This work includes: the investigation of the properties of various magnetic materials, their fabrication processes and their suitability for MEMS; finite element analysis to analyse the interaction between the magnetic materials and YBCO to determine the stiffness and height of levitation. Finally a micro-motor with the above principles is currently being fabricated within the group.

  16. Optimal economic and environment operation of micro-grid power systems

    International Nuclear Information System (INIS)

    Elsied, Moataz; Oukaour, Amrane; Gualous, Hamid; Lo Brutto, Ottavio A.

    2016-01-01

    Highlights: • Real-time energy management system for Micro-Grid power systems is introduced. • The management system considered cost objective function and emission constraints. • The optimization problem is solved using Binary Particle Swarm Algorithm. • Advanced real-time interface libraries are used to run the optimization code. - Abstract: In this paper, an advanced real-time energy management system is proposed in order to optimize micro-grid performance in a real-time operation. The proposed strategy of the management system capitalizes on the power of binary particle swarm optimization algorithm to minimize the energy cost and carbon dioxide and pollutant emissions while maximizing the power of the available renewable energy resources. Advanced real-time interface libraries are used to run the optimization code. The simulation results are considered for three different scenarios considering the complexity of the proposed problem. The proposed management system along with its control system is experimentally tested to validate the simulation results obtained from the optimization algorithm. The experimental results highlight the effectiveness of the proposed management system for micro-grids operation.

  17. Advanced biomaterials and their potential applications in the treatment of periodontal disease.

    Science.gov (United States)

    Chen, Xi; Wu, Guofeng; Feng, Zhihong; Dong, Yan; Zhou, Wei; Li, Bei; Bai, Shizhu; Zhao, Yimin

    2016-08-01

    Periodontal disease is considered as a widespread infectious disease and the most common cause of tooth loss in adults. Attempts for developing periodontal disease treatment strategies, including drug delivery and regeneration approaches, provide a useful experimental model for the evaluation of future periodontal therapies. Recently, emerging advanced biomaterials including hydrogels, films, micro/nanofibers and particles, hold great potential to be utilized as cell/drug carriers for local drug delivery and biomimetic scaffolds for future regeneration therapies. In this review, first, we describe the pathogenesis of periodontal disease, including plaque formation, immune response and inflammatory reactions caused by bacteria. Second, periodontal therapy and an overview of current biomaterials in periodontal regenerative medicine have been discussed. Third, the roles of state-of-the-art biomaterials, including hydrogels, films, micro/nanofibers and micro/nanoparticles, developed for periodontal disease treatment and periodontal tissue regeneration, and their fabrication methods, have been presented. Finally, biological properties, including biocompatibility, biodegradability and immunogenicity of the biomaterials, together with their current applications strategies are given. Conclusive remarks and future perspectives for such advanced biomaterials are discussed.

  18. The preparation method of solid boron solution in silicon carbide in the form of micro powder

    International Nuclear Information System (INIS)

    Pampuch, R.; Stobierski, L.; Lis, J.; Bialoskorski, J.; Ermer, E.

    1993-01-01

    The preparation method of solid boron solution in silicon carbide in the form of micro power has been worked out. The method consists in introducing mixture of boron, carbon and silicon and heating in the atmosphere of inert gas to the 1573 K

  19. A micro-macro acceleration method for the Monte Carlo simulation of stochastic differential equations

    DEFF Research Database (Denmark)

    Debrabant, Kristian; Samaey, Giovanni; Zieliński, Przemysław

    2017-01-01

    We present and analyse a micro-macro acceleration method for the Monte Carlo simulation of stochastic differential equations with separation between the (fast) time-scale of individual trajectories and the (slow) time-scale of the macroscopic function of interest. The algorithm combines short...

  20. MicroRNA expression profiles of multiple system atrophy from formalin-fixed paraffin-embedded samples.

    Science.gov (United States)

    Wakabayashi, Koichi; Mori, Fumiaki; Kakita, Akiyoshi; Takahashi, Hitoshi; Tanaka, Shinya; Utsumi, Jun; Sasaki, Hidenao

    2016-12-02

    MicroRNAs (miRNAs) are small noncoding RNAs that regulate gene expression. Recently, we have shown that informative miRNA data can be derived from archived formalin-fixed paraffin-embedded (FFPE) samples from postmortem cases of amyotrophic lateral sclerosis and normal controls. miRNA analysis has now been performed on FFPE samples from affected brain regions in patients with multiple system atrophy (MSA) and the same areas in neurologically normal controls. We evaluated 50 samples from patients with MSA (n=13) and controls (n=13). Twenty-six samples were selected for miRNA analysis on the basis of the criteria reported previously: (i) a formalin fixation time of less than 4 weeks, (ii) a total RNA yield per sample of more than 500ng, and (iii) sufficient quality of the RNA electrophoresis pattern. These included 11 cases of MSA and 5 controls. Thus, the success rate for analysis of RNA from FFPE samples was 52% (26 of 50). For MSA, a total of 395 and 383 miRNAs were identified in the pons and cerebellum, respectively; 5 were up-regulated and 33 were down-regulated in the pons and 5 were up-regulated and 18 were down-regulated in the cerebellum. Several miRNAs down-regulated in the pons (miR-129-2-3p and miR-129-5p) and cerebellum (miR-129-2-3p, miR-129-5p and miR-132-3p) had already been identified in frozen cerebellum from MSA patients. These findings suggest that archived FFPE postmortem samples can be a valuable source for miRNA profiling in MSA. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  1. Single-gene prognostic signatures for advanced stage serous ovarian cancer based on 1257 patient samples.

    Science.gov (United States)

    Zhang, Fan; Yang, Kai; Deng, Kui; Zhang, Yuanyuan; Zhao, Weiwei; Xu, Huan; Rong, Zhiwei; Li, Kang

    2018-04-16

    We sought to identify stable single-gene prognostic signatures based on a large collection of advanced stage serous ovarian cancer (AS-OvCa) gene expression data and explore their functions. The empirical Bayes (EB) method was used to remove the batch effect and integrate 8 ovarian cancer datasets. Univariate Cox regression was used to evaluate the association between gene and overall survival (OS). The Database for Annotation, Visualization and Integrated Discovery (DAVID) tool was used for the functional annotation of genes for Gene Ontology (GO) terms and Kyoto Encyclopedia of Genes and Genomes (KEGG) pathways. The batch effect was removed by the EB method, and 1257 patient samples were used for further analysis. We selected 341 single-gene prognostic signatures with FDR matrix organization, focal adhesion and DNA replication which are closely associated with cancer. We used the EB method to remove the batch effect of 8 datasets, integrated these datasets and identified stable prognosis signatures for AS-OvCa.

  2. Mini and micro spectrometers pave the way to on-field advanced analytics

    Science.gov (United States)

    Bouyé, Clémentine; Kolb, Hugo; d'Humières, Benoît.

    2016-03-01

    First introduced in the 1990's, miniature optical spectrometers were compact, portable devices brought on the market by the desire to move from time-consuming lab-based analyses to on-field and in situ measurements. This goal of getting spectroscopy into the hands of non-specialists is driving current technical and application developments, the ultimate goal being, in a far future, the integration of a spectrometer into a smartphone or any other smart device (tablet, watch, …). In this article, we present the results of our study on the evolution of the compact spectrometers market towards widespread industrial use and consumer applications. Presently, the main market of compact spectrometers remains academic labs. However, they have been adopted on some industrial applications such as optical source characterization (mainly laser and LEDs). In a near future, manufacturers of compact spectrometers target the following industrial applications: agriculture crop monitoring, food process control or pharmaceuticals quality control. Next steps will be to get closer to the consumer market with point-of-care applications such as glucose detection for diabetics, for example. To reach these objectives, technological breakthroughs will be necessary. Recent progresses have already allowed the release of micro-spectrometers. They take advantage of new micro-technologies such as MEMS (MicroElectroMechanical Systems), MOEMS (Micro-Opto-Electro-Mechanical Systems), micro-mirrors arrays to reduce cost and size while allowing good performance and high volume manufacturability. Integrated photonics is being investigated for future developments. It will also require new business models and new market approaches. Indeed, spreading spectroscopy to more industrial and consumer applications will require spectrometers manufacturers to get closer to the end-users and develop application-oriented products.

  3. Standard methods for sampling and sample preparation for gamma spectroscopy

    International Nuclear Information System (INIS)

    Taskaeva, M.; Taskaev, E.; Nikolov, P.

    1993-01-01

    The strategy for sampling and sample preparation is outlined: necessary number of samples; analysis and treatment of the results received; quantity of the analysed material according to the radionuclide concentrations and analytical methods; the minimal quantity and kind of the data needed for making final conclusions and decisions on the base of the results received. This strategy was tested in gamma spectroscopic analysis of radionuclide contamination of the region of Eleshnitsa Uranium Mines. The water samples was taken and stored according to the ASTM D 3370-82. The general sampling procedures were in conformity with the recommendations of ISO 5667. The radionuclides was concentrated by coprecipitation with iron hydroxide and ion exchange. The sampling of soil samples complied with the rules of ASTM C 998, and their sample preparation - with ASTM C 999. After preparation the samples were sealed hermetically and measured. (author)

  4. A general method for selection of riboflavin-overproducing food grade micro-organisms

    OpenAIRE

    Burgess, Catherine M; Smid, Eddy J; Rutten, Ger; van Sinderen, Douwe

    2006-01-01

    Abstract Background This study describes a strategy to select and isolate spontaneous riboflavin-overproducing strains of Lactobacillus (Lb.) plantarum, Leuconostoc (Lc.) mesenteroides and Propionibacterium (P.) freudenreichii. Results The toxic riboflavin analogue roseoflavin was used to isolate natural riboflavin-overproducing variants of the food grade micro-organisms Lb. plantarum, Lc. mesenteroides and P. freudenreichii strains. The method was successfully employed for strains of all thr...

  5. Damped time advance methods for particles and EM fields

    International Nuclear Information System (INIS)

    Friedman, A.; Ambrosiano, J.J.; Boyd, J.K.; Brandon, S.T.; Nielsen, D.E. Jr.; Rambo, P.W.

    1990-01-01

    Recent developments in the application of damped time advance methods to plasma simulations include the synthesis of implicit and explicit ''adjustably damped'' second order accurate methods for particle motion and electromagnetic field propagation. This paper discusses this method

  6. Fabrication of nanoplate resonating structures via micro-masonry

    International Nuclear Information System (INIS)

    Bhaswara, A; Legrand, B; Mathieu, F; Nicu, L; Leichle, T; Keum, H; Rhee, S; Kim, S

    2014-01-01

    Advantages of using nanoscale membrane and plate resonators over more common cantilever shapes include higher quality factor (Q factor) for an equivalent mass and better suitability to mass sensing applications in fluid. Unfortunately, the current fabrication methods used to obtain such membranes and plates are limited in terms of materials and thickness range, and can potentially cause stiction. This study presents a new method to fabricate nanoplate resonating structures based on micro-masonry, which is the advanced form of the transfer printing technique. Nanoplate resonators were fabricated by transfer printing 0.34 µm thick square-shaped silicon plates by means of polydimethylsiloxane microtip stamps on top of silicon oxide base structures displaying 20 µm diameter cavities, followed by a thermal annealing step to create a rigid bond. Typical resulting suspended structures display vibration characteristics, i.e. a resonance frequency of a few MHz and Q factors above 10 in air at atmospheric pressure, which are in accordance with theory. Moreover, the presented fabrication method enables the realization of multiple suspended structures in a single step and on the same single base, without mechanical crosstalk between the resonators. This work thus demonstrates the suitability and the advantages of the micro-masonry technique for the fabrication of plate resonators for mass sensing purpose. (paper)

  7. Sampling bee communities using pan traps: alternative methods increase sample size

    Science.gov (United States)

    Monitoring of the status of bee populations and inventories of bee faunas require systematic sampling. Efficiency and ease of implementation has encouraged the use of pan traps to sample bees. Efforts to find an optimal standardized sampling method for pan traps have focused on pan trap color. Th...

  8. New adaptive sampling method in particle image velocimetry

    International Nuclear Information System (INIS)

    Yu, Kaikai; Xu, Jinglei; Tang, Lan; Mo, Jianwei

    2015-01-01

    This study proposes a new adaptive method to enable the number of interrogation windows and their positions in a particle image velocimetry (PIV) image interrogation algorithm to become self-adapted according to the seeding density. The proposed method can relax the constraint of uniform sampling rate and uniform window size commonly adopted in the traditional PIV algorithm. In addition, the positions of the sampling points are redistributed on the basis of the spring force generated by the sampling points. The advantages include control of the number of interrogation windows according to the local seeding density and smoother distribution of sampling points. The reliability of the adaptive sampling method is illustrated by processing synthetic and experimental images. The synthetic example attests to the advantages of the sampling method. Compared with that of the uniform interrogation technique in the experimental application, the spatial resolution is locally enhanced when using the proposed sampling method. (technical design note)

  9. JSC Advanced Curation: Research and Development for Current Collections and Future Sample Return Mission Demands

    Science.gov (United States)

    Fries, M. D.; Allen, C. C.; Calaway, M. J.; Evans, C. A.; Stansbery, E. K.

    2015-01-01

    Curation of NASA's astromaterials sample collections is a demanding and evolving activity that supports valuable science from NASA missions for generations, long after the samples are returned to Earth. For example, NASA continues to loan hundreds of Apollo program samples to investigators every year and those samples are often analyzed using instruments that did not exist at the time of the Apollo missions themselves. The samples are curated in a manner that minimizes overall contamination, enabling clean, new high-sensitivity measurements and new science results over 40 years after their return to Earth. As our exploration of the Solar System progresses, upcoming and future NASA sample return missions will return new samples with stringent contamination control, sample environmental control, and Planetary Protection requirements. Therefore, an essential element of a healthy astromaterials curation program is a research and development (R&D) effort that characterizes and employs new technologies to maintain current collections and enable new missions - an Advanced Curation effort. JSC's Astromaterials Acquisition & Curation Office is continually performing Advanced Curation research, identifying and defining knowledge gaps about research, development, and validation/verification topics that are critical to support current and future NASA astromaterials sample collections. The following are highlighted knowledge gaps and research opportunities.

  10. Inferring microRNA regulation of mRNA with partially ordered samples of paired expression data and exogenous prediction algorithms.

    Directory of Open Access Journals (Sweden)

    Brian Godsey

    Full Text Available MicroRNAs (miRs are known to play an important role in mRNA regulation, often by binding to complementary sequences in "target" mRNAs. Recently, several methods have been developed by which existing sequence-based target predictions can be combined with miR and mRNA expression data to infer true miR-mRNA targeting relationships. It has been shown that the combination of these two approaches gives more reliable results than either by itself. While a few such algorithms give excellent results, none fully addresses expression data sets with a natural ordering of the samples. If the samples in an experiment can be ordered or partially ordered by their expected similarity to one another, such as for time-series or studies of development processes, stages, or types, (e.g. cell type, disease, growth, aging, there are unique opportunities to infer miR-mRNA interactions that may be specific to the underlying processes, and existing methods do not exploit this. We propose an algorithm which specifically addresses [partially] ordered expression data and takes advantage of sample similarities based on the ordering structure. This is done within a Bayesian framework which specifies posterior distributions and therefore statistical significance for each model parameter and latent variable. We apply our model to a previously published expression data set of paired miR and mRNA arrays in five partially ordered conditions, with biological replicates, related to multiple myeloma, and we show how considering potential orderings can improve the inference of miR-mRNA interactions, as measured by existing knowledge about the involved transcripts.

  11. Review of advanced imaging techniques

    Directory of Open Access Journals (Sweden)

    Yu Chen

    2012-01-01

    Full Text Available Pathology informatics encompasses digital imaging and related applications. Several specialized microscopy techniques have emerged which permit the acquisition of digital images ("optical biopsies" at high resolution. Coupled with fiber-optic and micro-optic components, some of these imaging techniques (e.g., optical coherence tomography are now integrated with a wide range of imaging devices such as endoscopes, laparoscopes, catheters, and needles that enable imaging inside the body. These advanced imaging modalities have exciting diagnostic potential and introduce new opportunities in pathology. Therefore, it is important that pathology informaticists understand these advanced imaging techniques and the impact they have on pathology. This paper reviews several recently developed microscopic techniques, including diffraction-limited methods (e.g., confocal microscopy, 2-photon microscopy, 4Pi microscopy, and spatially modulated illumination microscopy and subdiffraction techniques (e.g., photoactivated localization microscopy, stochastic optical reconstruction microscopy, and stimulated emission depletion microscopy. This article serves as a primer for pathology informaticists, highlighting the fundamentals and applications of advanced optical imaging techniques.

  12. Micro-manufacturing technologies and their applications a theoretical and practical guide

    CERN Document Server

    Shipley, David

    2017-01-01

    This book provides in-depth theoretical and practical information on recent advances in micro-manufacturing technologies and processes, covering such topics as micro-injection moulding, micro-cutting, micro-EDM, micro-assembly, micro-additive manufacturing, moulded interconnected devices, and microscale metrology. It is designed to provide complementary material for the related e-learning platform on micro-manufacturing developed within the framework of the Leonardo da Vinci project 2013-3748/542424: MIMAN-T: Micro-Manufacturing Training System for SMEs. The book is mainly addressed to technicians and prospective professionals in the sector and will serve as an easily usable tool to facilitate the translation of micro-manufacturing technologies into tangible industrial benefits. Numerous examples are included to assist readers in learning and implementing the described technologies. In addition, an individual chapter is devoted to technological foresight, addressing market analysis and business models for mic...

  13. Evaluation of OPPS model for plant operator's task simulation with Micro-SAINT

    International Nuclear Information System (INIS)

    Yoshida, Kazuo

    1991-03-01

    The development of a computer simulation method for cognitive behavior of operators under emergency conditions in nuclear power plant are being conducted at Japan Atomic Energy Research Institute (JAERI). As one of activities in this project, the task network modeling and simulation method has been evaluated with reproduced OPPS model using Micro-SAINT which is a PC software for task network analysis. OPPS is an operator's task simulation model developed by Oak Ridge National Laboratory. Operator's tasks under the condition of failure open of a safety relief valve in a BWR power plant has been analyzed as a sample problem with Micro-SAINT version of OPPS for the evaluation of task network analysis method. Furthermore, the fundamental capabilities of Micro-SAINT has been evaluated, and the task network in OPPS model has been also examined. As the results of this study, it has been clarified that random seed numbers in Micro-SAINT affect the probabilistic branching ratio and the distribution of task execution time calculated by Monte Carlo simulations, and the expression of network for a repeated task in the OPPS model leads to incorrect standard deviation in the case that a task execution time has some distribution. (author)

  14. Three dimensional subsurface elemental identification of minerals using confocal micro-X-ray fluorescence and micro-X-ray computed tomography

    International Nuclear Information System (INIS)

    Cordes, Nikolaus L.; Seshadri, Srivatsan; Havrilla, George J.; Yuan, Xiaoli; Feser, Michael; Patterson, Brian M.

    2015-01-01

    Current non-destructive elemental characterization methods, such as scanning electron microscopy-based energy dispersive spectroscopy (SEM–EDS) and micro-X-ray fluorescence spectroscopy (MXRF), are limited to either elemental identification at the surface (SEM–EDS) or suffer from an inability to discriminate between surface or depth information (MXRF). Thus, a non-destructive elemental characterization of individual embedded particles beneath the surface is impossible with either of these techniques. This limitation can be overcome by using laboratory-based 3D confocal micro-X-ray fluorescence spectroscopy (confocal MXRF). This technique utilizes focusing optics on the X-ray source and detector which allows for spatial discrimination in all three dimensions. However, the voxel-by-voxel serial acquisition of a 3D elemental scan can be very time-intensive (~ 1 to 4 weeks) if it is necessary to locate individual embedded particles of interest. As an example, if each point takes a 5 s measurement time, a small volume of 50 × 50 × 50 pixels leads to an acquisition time of approximately 174 h, not including sample stage movement time. Initially screening the samples for particles of interest using micro-X-ray computed tomography (micro-CT) can significantly reduce the time required to spatially locate these particles. Once located, these individual particles can be elementally characterized with confocal MXRF. Herein, we report the elemental identification of high atomic number surface and subsurface particles embedded in a mineralogical matrix by coupling micro-CT and confocal MXRF. Synergistically, these two X-ray based techniques first rapidly locate and then elementally identify individual subsurface particles. - Highlights: • Coupling of confocal X-ray fluorescence spectroscopy and X-ray computed tomography • Qualitative elemental identification of surface and subsurface mineral particles • Non-destructive particle size measurements • Utilization of

  15. Three dimensional subsurface elemental identification of minerals using confocal micro-X-ray fluorescence and micro-X-ray computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Cordes, Nikolaus L., E-mail: ncordes@lanl.gov [Polymers and Coatings Group, Material Science and Technology Division, Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Seshadri, Srivatsan, E-mail: srivatsan.seshadri@zeiss.com [Carl Zeiss X-ray Microscopy, Inc., Pleasanton, CA 94588 (United States); Havrilla, George J. [Chemical Diagnostics and Engineering, Chemistry Division, Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Yuan, Xiaoli [Julius Kruttschnitt Mineral Research Centre, University of Queensland, Indooroopilly, Brisbane, QLD 4068 (Australia); Feser, Michael [Carl Zeiss X-ray Microscopy, Inc., Pleasanton, CA 94588 (United States); Patterson, Brian M. [Polymers and Coatings Group, Material Science and Technology Division, Los Alamos National Laboratory, Los Alamos, NM 87545 (United States)

    2015-01-01

    Current non-destructive elemental characterization methods, such as scanning electron microscopy-based energy dispersive spectroscopy (SEM–EDS) and micro-X-ray fluorescence spectroscopy (MXRF), are limited to either elemental identification at the surface (SEM–EDS) or suffer from an inability to discriminate between surface or depth information (MXRF). Thus, a non-destructive elemental characterization of individual embedded particles beneath the surface is impossible with either of these techniques. This limitation can be overcome by using laboratory-based 3D confocal micro-X-ray fluorescence spectroscopy (confocal MXRF). This technique utilizes focusing optics on the X-ray source and detector which allows for spatial discrimination in all three dimensions. However, the voxel-by-voxel serial acquisition of a 3D elemental scan can be very time-intensive (~ 1 to 4 weeks) if it is necessary to locate individual embedded particles of interest. As an example, if each point takes a 5 s measurement time, a small volume of 50 × 50 × 50 pixels leads to an acquisition time of approximately 174 h, not including sample stage movement time. Initially screening the samples for particles of interest using micro-X-ray computed tomography (micro-CT) can significantly reduce the time required to spatially locate these particles. Once located, these individual particles can be elementally characterized with confocal MXRF. Herein, we report the elemental identification of high atomic number surface and subsurface particles embedded in a mineralogical matrix by coupling micro-CT and confocal MXRF. Synergistically, these two X-ray based techniques first rapidly locate and then elementally identify individual subsurface particles. - Highlights: • Coupling of confocal X-ray fluorescence spectroscopy and X-ray computed tomography • Qualitative elemental identification of surface and subsurface mineral particles • Non-destructive particle size measurements • Utilization of

  16. On-line liquid phase micro-extraction based on drop-in-plug sequential injection lab-at-valve platform for metal determination

    Energy Technology Data Exchange (ETDEWEB)

    Mitani, Constantina [Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University, Thessaloniki 54124 (Greece); Anthemidis, Aristidis N., E-mail: anthemid@chem.auth.gr [Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University, Thessaloniki 54124 (Greece)

    2013-04-10

    Highlights: ► Drop-in-plug micro-extraction based on SI-LAV platform for metal preconcentration. ► Automatic liquid phase micro-extraction coupled with FAAS. ► Organic solvents with density higher than water are used. ► Lead determination in environmental water and urine samples. -- Abstract: A novel automatic on-line liquid phase micro-extraction method based on drop-in-plug sequential injection lab-at-valve (LAV) platform was proposed for metal preconcentration and determination. A flow-through micro-extraction chamber mounted at the selection valve was adopted without the need of sophisticated lab-on-valve components. Coupled to flame atomic absorption spectrometry (FAAS), the potential of this lab-at-valve scheme is demonstrated for trace lead determination in environmental and biological water samples. A hydrophobic complex of lead with ammonium pyrrolidine dithiocarbamate (APDC) was formed on-line and subsequently extracted into an 80 μL plug of chloroform. The extraction procedure was performed by forming micro-droplets of aqueous phase into the plug of the extractant. All critical parameters that affect the efficiency of the system were studied and optimized. The proposed method offered good performance characteristics and high preconcentration ratios. For 10 mL sample consumption an enhancement factor of 125 was obtained. The detection limit was 1.8 μg L{sup −1} and the precision expressed as relative standard deviation (RSD) at 50.0 μg L{sup −1} of lead was 2.9%. The proposed method was evaluated by analyzing certified reference materials and applied for lead determination in natural waters and urine samples.

  17. Application of benchtop micro-XRF to geological materials

    DEFF Research Database (Denmark)

    Flude, Stephanie; Haschke, Michael; Storey, Michael

    2017-01-01

    Recent developments in X-ray optics have allowed the development of a range of commercially available benchtop micro-XRF (μ-XRF) instruments that can produce X-ray spot sizes of 20–30 μm on the sample, allowing major- and trace-element analysis on a range of sample types and sizes with minimal......, by using a simple type-calibration against a reference material of similar matrix and composition. Qualitative analysis with micro-XRF can simplify and streamline sample characterization and processing for subsequent geochemical and isotopic analysis....... sample preparation. Such instruments offer quantitative analysis using fundamental parameter based 'standardless' quantification algorithms. The accuracy and precision of this quantitative analysis on geological materials, and application of micro-XRF to wider geological problems is assessed using...

  18. Sample normalization methods in quantitative metabolomics.

    Science.gov (United States)

    Wu, Yiman; Li, Liang

    2016-01-22

    To reveal metabolomic changes caused by a biological event in quantitative metabolomics, it is critical to use an analytical tool that can perform accurate and precise quantification to examine the true concentration differences of individual metabolites found in different samples. A number of steps are involved in metabolomic analysis including pre-analytical work (e.g., sample collection and storage), analytical work (e.g., sample analysis) and data analysis (e.g., feature extraction and quantification). Each one of them can influence the quantitative results significantly and thus should be performed with great care. Among them, the total sample amount or concentration of metabolites can be significantly different from one sample to another. Thus, it is critical to reduce or eliminate the effect of total sample amount variation on quantification of individual metabolites. In this review, we describe the importance of sample normalization in the analytical workflow with a focus on mass spectrometry (MS)-based platforms, discuss a number of methods recently reported in the literature and comment on their applicability in real world metabolomics applications. Sample normalization has been sometimes ignored in metabolomics, partially due to the lack of a convenient means of performing sample normalization. We show that several methods are now available and sample normalization should be performed in quantitative metabolomics where the analyzed samples have significant variations in total sample amounts. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Micro-fabricated integrated coil and magnetic circuit and method of manufacturing thereof

    Science.gov (United States)

    Mihailovich, Robert E.; Papavasiliou, Alex P.; Mehrotra, Vivek; Stupar, Philip A.; Borwick, III, Robert L.; Ganguli, Rahul; DeNatale, Jeffrey F.

    2017-03-28

    A micro-fabricated electromagnetic device is provided for on-circuit integration. The electromagnetic device includes a core. The core has a plurality of electrically insulating layers positioned alternatingly between a plurality of magnetic layers to collectively form a continuous laminate having alternating magnetic and electrically insulating layers. The electromagnetic device includes a coil embedded in openings of the semiconductor substrate. An insulating material is positioned in the cavity and between the coil and an inner surface of the core. A method of manufacturing the electromagnetic device includes providing a semiconductor substrate having openings formed therein. Windings of a coil are electroplated and embedded in the openings. The insulating material is coated on or around an exposed surface of the coil. Alternating magnetic layers and electrically insulating layers may be micro-fabricated and electroplated as a single and substantially continuous segment on or around the insulating material.

  20. Intelligent color recognition system using micro-controller

    International Nuclear Information System (INIS)

    Mohd Ashhar Khalid; Khairiah Yazid; Nur Aira Abd Rahman; Azaman Ahmad

    2006-01-01

    Color is widely used in categorizing the quality of products as well as a marker for automatic selection and discrimination of products. Most of color recognizing process is done manually and due to the fact that human perceived color differently, different of opinion frequently occur. This paper deals with the development of an intelligent color recognition system used for discriminating the ripeness of oil palm fruits into three categories namely ripe, under-ripe and un-ripe. In deciding the categories of fruit a sample belong, a technique of decision making similar to human thinking called neural network has been implemented. Implementation of neural network using a micro-controller is not so common, due to a limited capability in floating point calculation. To overcome the problem, a floating-point co-processor specially designed for micro-controller is used. The paper will report the system design and the network training and implementation methods. The effectiveness of the system compared to human decision method is also reported. (Author)

  1. Advanced Data Mining of Leukemia Cells Micro-Arrays

    OpenAIRE

    Richard S. Segall; Ryan M. Pierce

    2009-01-01

    This paper provides continuation and extensions of previous research by Segall and Pierce (2009a) that discussed data mining for micro-array databases of Leukemia cells for primarily self-organized maps (SOM). As Segall and Pierce (2009a) and Segall and Pierce (2009b) the results of applying data mining are shown and discussed for the data categories of microarray databases of HL60, Jurkat, NB4 and U937 Leukemia cells that are also described in this article. First, a background section is pro...

  2. Method for detecting binding events using micro-X-ray fluorescence spectrometry

    Science.gov (United States)

    Warner, Benjamin P.; Havrilla, George J.; Mann, Grace

    2010-12-28

    Method for detecting binding events using micro-X-ray fluorescence spectrometry. Receptors are exposed to at least one potential binder and arrayed on a substrate support. Each member of the array is exposed to X-ray radiation. The magnitude of a detectable X-ray fluorescence signal for at least one element can be used to determine whether a binding event between a binder and a receptor has occurred, and can provide information related to the extent of binding between the binder and receptor.

  3. MicroCar 2003. Abstracts of papers

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-07-01

    Mechatronics for automotive applications is an important trend, combining mechanics, electronics and information technology. Micro- and nanomechatronics, particularly innovative research disciplines, will help create, in combination with advanced solutions from microsystem technologies, e.g. the electronic packaging, a range of entirely new developments in automobiles. Under the umbrella of the Automotive Suppliers Fair Z2003, it is happening for the very first time now that a momentous scientific conference, such as the MicroCar 2003, brings together representatives from car manufacturers and the electronics industry, as well as a large number of experts from technical colleges, universities and research institutes to discuss the new potentials and possibilities presented by the use of micro and nanomaterials in Leipzig. With the presentation of 50 papers, speakers will inform about their latest research results as well as current trends in micro and nanotechnologies for automotives. This issue is publishing the abstracts of this scientific event.

  4. Identification of differentially expressed microRNAs in human male breast cancer

    Directory of Open Access Journals (Sweden)

    Schipper Elisa

    2010-03-01

    Full Text Available Abstract Background The discovery of small non-coding RNAs and the subsequent analysis of microRNA expression patterns in human cancer specimens have provided completely new insights into cancer biology. Genetic and epigenetic data indicate oncogenic or tumor suppressor function of these pleiotropic regulators. Therefore, many studies analyzed the expression and function of microRNA in human breast cancer, the most frequent malignancy in females. However, nothing is known so far about microRNA expression in male breast cancer, accounting for approximately 1% of all breast cancer cases. Methods The expression of 319 microRNAs was analyzed in 9 primary human male breast tumors and in epithelial cells from 15 male gynecomastia specimens using fluorescence-labeled bead technology. For identification of differentially expressed microRNAs data were analyzed by cluster analysis and selected statistical methods. Expression levels were validated for the most up- or down-regulated microRNAs in this training cohort using real-time PCR methodology as well as in an independent test cohort comprising 12 cases of human male breast cancer. Results Unsupervised cluster analysis separated very well male breast cancer samples and control specimens according to their microRNA expression pattern indicating cancer-specific alterations of microRNA expression in human male breast cancer. miR-21, miR519d, miR-183, miR-197, and miR-493-5p were identified as most prominently up-regulated, miR-145 and miR-497 as most prominently down-regulated in male breast cancer. Conclusions Male breast cancer displays several differentially expressed microRNAs. Not all of them are shared with breast cancer biopsies from female patients indicating male breast cancer specific alterations of microRNA expression.

  5. Micro- and nanodevices integrated with biomolecular probes.

    Science.gov (United States)

    Alapan, Yunus; Icoz, Kutay; Gurkan, Umut A

    2015-12-01

    Understanding how biomolecules, proteins and cells interact with their surroundings and other biological entities has become the fundamental design criterion for most biomedical micro- and nanodevices. Advances in biology, medicine, and nanofabrication technologies complement each other and allow us to engineer new tools based on biomolecules utilized as probes. Engineered micro/nanosystems and biomolecules in nature have remarkably robust compatibility in terms of function, size, and physical properties. This article presents the state of the art in micro- and nanoscale devices designed and fabricated with biomolecular probes as their vital constituents. General design and fabrication concepts are presented and three major platform technologies are highlighted: microcantilevers, micro/nanopillars, and microfluidics. Overview of each technology, typical fabrication details, and application areas are presented by emphasizing significant achievements, current challenges, and future opportunities. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Validation of micro-CT against the section method regarding the assessment of marginal leakage of sealants.

    NARCIS (Netherlands)

    Chen, X.; Cuijpers, V.M.J.I.; Fan, M.W.; Frencken, J.E.F.M.

    2012-01-01

    BACKGROUND: The aim of this study was to validate the micro-CT and related software against the section method using the stereomicroscope for marginal leakage assessment along the sealant-enamel interface. METHODS: Pits and fissures of the occlusal surface of 10 teeth were sealed with a

  7. Handbook on advanced design and manufacturing technologies for biomedical devices

    CERN Document Server

    2013-01-01

    The last decades have seen remarkable advances in computer-aided design, engineering and manufacturing technologies, multi-variable simulation tools, medical imaging, biomimetic design, rapid prototyping, micro and nanomanufacturing methods and information management resources, all of which provide new horizons for the Biomedical Engineering fields and the Medical Device Industry. Handbook on Advanced Design and Manufacturing Technologies for Biomedical Devices covers such topics in depth, with an applied perspective and providing several case studies that help to analyze and understand the key factors of the different stages linked to the development of a novel biomedical device, from the conceptual and design steps, to the prototyping and industrialization phases. Main research challenges and future potentials are also discussed, taking into account relevant social demands and a growing market already exceeding billions of dollars. In time, advanced biomedical devices will decisively change methods and resu...

  8. Advanced accelerator methods: The cyclotrino

    International Nuclear Information System (INIS)

    Welch, J.J.; Bertsche, K.J.; Friedman, P.G.; Morris, D.E.; Muller, R.A.

    1987-04-01

    Several new and unusual, advanced techniques in the small cyclotron are described. The cyclotron is run at low energy, using negative ions and at high harmonics. Electrostatic focusing is used exclusively. The ion source and injection system is in the center, which unfortunately does not provide enough current, but the new system design should solve this problem. An electrostatic extractor that runs at low voltage, under 5 kV, and a microchannel plate detector which is able to discriminate low energy ions from the 14 C are used. The resolution is sufficient for 14 C dating and a higher intensity source should allow dating of a milligram size sample of 30,000 year old material with less than 10% uncertainty

  9. A hydrazone covalent organic polymer based micro-solid phase extraction for online analysis of trace Sudan dyes in food samples.

    Science.gov (United States)

    Zhang, Chengjiang; Li, Gongke; Zhang, Zhuomin

    2015-11-06

    Covalent organic polymers (COPs) connected by covalent bonds are a new class of porous network materials with large surface area and potential superiority in sample pretreatment. In this study, a new hydrazone linked covalent organic polymer (HL-COP) adsorbent was well-designed and synthesized based on a simple Schiff-base reaction. The condensation of 1,4-phthalaldehyde and 1,3,5-benzenetricarbohydrazide as organic building blocks led to the synthesis of HL-COP with uniform particle size and good adsorption performance. This HL-COP adsorbent with high hydrophobic property and rich stacking π electrons contained abundant phenyl rings and imine (CN) groups throughout the entire molecular framework. The adsorption mechanism was explored and discussed based on π-π affinity, hydrophobic effect, hydrogen bonding and electron-donor-acceptor (EDA) interaction, which contributed to its strong recognition affinity to target compounds. Enrichment factors were 305-757 for six Sudan dyes by HL-COP micro-solid phase extraction (μ-SPE), indicating its remarkable preconcentration ability. Furthermore, the adsorption amounts by HL-COP μ-SPE were 1.0-11.0 folds as those by three commonly used commercial adsorbents. Then, HL-COP was applied as adsorbent of online μ-SPE coupled with high performance liquid chromatography (HPLC) for enrichment and analysis of trace Sudan dyes in food samples with detection limit of 0.03-0.15μg/L. The method was successfully applied for online analysis of chilli powder and sausage samples. Sudan II and Sudan III in one positive chilli powder sample were actually found and determined with concentrations of 8.3 and 6.8μg/kg, respectively. The recoveries of chilli powder and sausage samples were in range of 75.8-108.2% and 73.8-112.6% with relative standard deviations of 1.2-8.5% and 1.9-9.4% (n=5), respectively. The proposed method was accurate, reliable and convenient for the online simultaneous analysis of trace Sudan dyes in food samples

  10. Development of 3d micro-nano hybrid patterns using anodized aluminum and micro-indentation

    International Nuclear Information System (INIS)

    Shin, Hong Gue; Kwon, Jong Tae; Seo, Young Ho; Kim, Byeong Hee

    2008-01-01

    We developed a simple and cost-effective method of fabricating 3D micro-nano hybrid patterns in which micro-indentation is applied on the anodized aluminum substrate. Nano-patterns were formed first on the aluminum substrate, and then micro-patterns were fabricated by deforming the nano-patterned aluminum substrate. Hemispherical nano-patterns with a 150 nm-diameter on an aluminum substrate were fabricated by anodizing and alumina removing process. Then, micro-pyramid patterns with a side-length of 50 μm were formed on the nano-patterns using micro-indentation. To verify 3D micro-nano hybrid patterns, we replicated 3D micro-nano hybrid patterns by a hot-embossing process. 3D micro-nano hybrid patterns may be used in nano-photonic devices and nano-biochips applications

  11. Development of 3d micro-nano hybrid patterns using anodized aluminum and micro-indentation

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Hong Gue; Kwon, Jong Tae [Division of Mechanical Engineering and Mechatronics, Kangwon National University, 1 Kangwondaehakgil, Chunchon, Gangwon-do, 200-701 (Korea, Republic of); Seo, Young Ho [Division of Mechanical Engineering and Mechatronics, Kangwon National University, 1 Kangwondaehakgil, Chunchon, Gangwon-do, 200-701 (Korea, Republic of)], E-mail: mems@kangwon.ac.kr; Kim, Byeong Hee [Division of Mechanical Engineering and Mechatronics, Kangwon National University, 1 Kangwondaehakgil, Chunchon, Gangwon-do, 200-701 (Korea, Republic of)

    2008-07-31

    We developed a simple and cost-effective method of fabricating 3D micro-nano hybrid patterns in which micro-indentation is applied on the anodized aluminum substrate. Nano-patterns were formed first on the aluminum substrate, and then micro-patterns were fabricated by deforming the nano-patterned aluminum substrate. Hemispherical nano-patterns with a 150 nm-diameter on an aluminum substrate were fabricated by anodizing and alumina removing process. Then, micro-pyramid patterns with a side-length of 50 {mu}m were formed on the nano-patterns using micro-indentation. To verify 3D micro-nano hybrid patterns, we replicated 3D micro-nano hybrid patterns by a hot-embossing process. 3D micro-nano hybrid patterns may be used in nano-photonic devices and nano-biochips applications.

  12. Metal removal from tailings ponds water using indigenous micro-algae

    Energy Technology Data Exchange (ETDEWEB)

    Mahdavi, H.; Ulrich, A.; Liu, Y. [Alberta Univ., Edmonton, AB (Canada). Dept. of Civil and Environmental Engineering

    2010-07-01

    Each barrel of oil produced by oil sands produce 1.25 m{sup 3} of tailings. The tailings are collected in ponds located at mining sites. The tailing pond water (TPW) must be reclaimed and released into the environment. This PowerPoint presentation discussed a method of removing metals from tailings pond water that used indigenous micro-algae. The in situ experimental method used Parachlorella kessliri to treat 2 ponds. The TPW was enriched with low and high concentrations of nutrients. Dry cell biomass analyses were then conducted, and the pH of the resulting samples was compared. Inductively coupled plasma mass spectrometry analysis methods were used to determine the initial metal concentrations in the raw TPWs. The study showed that the micro-algae remove significantly more metals when high levels of nutrients are used. tabs., figs.

  13. Advances in Integrating Autonomy with Acoustic Communications for Intelligent Networks of Marine Robots

    Science.gov (United States)

    2013-02-01

    whole or in part is permitted for any purpose of the United States Government . This thesis should be cited as: Toby Edwin Schneider, 2013. Advances...Sonar AUV #Environmental Sampling Environmental AUV +name : string = OEX Ocean Explorer +name : string = Hammerhead Iver2 +name : string = Unicorn ...executable» Google Earth Bluefin 21 AUV ( Unicorn ) MOOS Computer GPS «serial» Bluefin 21 AUV (Macrura) MOOS Computer «acoustic» Micro-Modem «wired

  14. Bioinspiration From Nano to Micro Scales

    CERN Document Server

    2012-01-01

    Methods in bioinspiration and biomimicking have been around for a long time. However, due to current advances in modern physical, biological sciences, and technologies, our understanding of the methods have evolved to a new level. This is due not only to the identification of mysterious and fascinating phenomena but also to the understandings of the correlation between the structural factors and the performance based on the latest theoretical, modeling, and experimental technologies. Bioinspiration: From Nano to Micro Scale provides readers with a broad view of the frontiers of research in the area of bioinspiration from the nano to macroscopic scales, particularly in the areas of biomineralization, antifreeze protein, and antifreeze effect. It also covers such methods as the lotus effect and superhydrophobicity, structural colors in animal kingdom and beyond, as well as behavior in ion channels. A number of international experts in related fields have contributed to this book, which offers a comprehensive an...

  15. Micro-Doppler Ambiguity Resolution Based on Short-Time Compressed Sensing

    Directory of Open Access Journals (Sweden)

    Jing-bo Zhuang

    2015-01-01

    Full Text Available When using a long range radar (LRR to track a target with micromotion, the micro-Doppler embodied in the radar echoes may suffer from ambiguity problem. In this paper, we propose a novel method based on compressed sensing (CS to solve micro-Doppler ambiguity. According to the RIP requirement, a sparse probing pulse train with its transmitting time random is designed. After matched filtering, the slow-time echo signals of the micromotion target can be viewed as randomly sparse sampling of Doppler spectrum. Select several successive pulses to form a short-time window and the CS sensing matrix can be built according to the time stamps of these pulses. Then performing Orthogonal Matching Pursuit (OMP, the unambiguous micro-Doppler spectrum can be obtained. The proposed algorithm is verified using the echo signals generated according to the theoretical model and the signals with micro-Doppler signature produced using the commercial electromagnetic simulation software FEKO.

  16. Non-contact micro mass evaluation method using an X-ray microscope

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jiseok; Sun, Gwang Min; Baek, Ha Ni; Hoang, Sy Minh Tuan; Park, Sun Ae [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2017-07-15

    For the mass inspection of attached foils such as printed electrodes, mass should be measured by a non-contact method with the capacity to measure a small mass of micrograms. In this study, the masses of 1 mg to 10 mg electrodes were evaluated using an X-ray microscope. The results were compared with the masses determined by using a digital scale with a 0.005 mg error. The average of the relative error between the mass measurements using the X-ray microscope and those using the digital scale was less than 2.51%. The results show that X-ray mass evaluation method can be used for mass measurement of micro objects by replacing a digital scale.

  17. Ammonium vanadate titrimetric method for determination of micro amount uranium in rock and soil by using vanadate-gold indicator

    International Nuclear Information System (INIS)

    Li Yucheng.

    1990-01-01

    A new vanadate-gold indicator was successfully applied to the ammonium vanadate titrimetric method for determination of micro amount uranium in rock and soil. Uranium in 0.1g of sample is reduced by titanium trichloride in phosphoric acid. Excessive Ti (III) and other low-valent ions are oxidized by sodium nitrite, while the complex of uranium (IV)-phosphate is not oxidized. Excessive nitrite is destroyed by urea. When the concentration of phosphoric acid is 22-24 % , adding two drops of vanadate-gold indicator, uranium (IV) is titrated by standardized ammonium vanadate solution (T = 0.02-20gU/ml) and the end-point is judged by a violet-red color appearance

  18. Fluidics platform and method for sample preparation

    Science.gov (United States)

    Benner, Henry W.; Dzenitis, John M.

    2016-06-21

    Provided herein are fluidics platforms and related methods for performing integrated sample collection and solid-phase extraction of a target component of the sample all in one tube. The fluidics platform comprises a pump, particles for solid-phase extraction and a particle-holding means. The method comprises contacting the sample with one or more reagents in a pump, coupling a particle-holding means to the pump and expelling the waste out of the pump while the particle-holding means retains the particles inside the pump. The fluidics platform and methods herein described allow solid-phase extraction without pipetting and centrifugation.

  19. MicroRNA Array Normalization: An Evaluation Using a Randomized Dataset as the Benchmark

    Science.gov (United States)

    Qin, Li-Xuan; Zhou, Qin

    2014-01-01

    MicroRNA arrays possess a number of unique data features that challenge the assumption key to many normalization methods. We assessed the performance of existing normalization methods using two microRNA array datasets derived from the same set of tumor samples: one dataset was generated using a blocked randomization design when assigning arrays to samples and hence was free of confounding array effects; the second dataset was generated without blocking or randomization and exhibited array effects. The randomized dataset was assessed for differential expression between two tumor groups and treated as the benchmark. The non-randomized dataset was assessed for differential expression after normalization and compared against the benchmark. Normalization improved the true positive rate significantly in the non-randomized data but still possessed a false discovery rate as high as 50%. Adding a batch adjustment step before normalization further reduced the number of false positive markers while maintaining a similar number of true positive markers, which resulted in a false discovery rate of 32% to 48%, depending on the specific normalization method. We concluded the paper with some insights on possible causes of false discoveries to shed light on how to improve normalization for microRNA arrays. PMID:24905456

  20. Applications of Micro-Fourier Transform Infrared Spectroscopy (FTIR) in the Geological Sciences—A Review

    Science.gov (United States)

    Chen, Yanyan; Zou, Caineng; Mastalerz, Maria; Hu, Suyun; Gasaway, Carley; Tao, Xiaowan

    2015-01-01

    Fourier transform infrared spectroscopy (FTIR) can provide crucial information on the molecular structure of organic and inorganic components and has been used extensively for chemical characterization of geological samples in the past few decades. In this paper, recent applications of FTIR in the geological sciences are reviewed. Particularly, its use in the characterization of geochemistry and thermal maturation of organic matter in coal and shale is addressed. These investigations demonstrate that the employment of high-resolution micro-FTIR imaging enables visualization and mapping of the distributions of organic matter and minerals on a micrometer scale in geological samples, and promotes an advanced understanding of heterogeneity of organic rich coal and shale. Additionally, micro-FTIR is particularly suitable for in situ, non-destructive characterization of minute microfossils, small fluid and melt inclusions within crystals, and volatiles in glasses and minerals. This technique can also assist in the chemotaxonomic classification of macrofossils such as plant fossils. These features, barely accessible with other analytical techniques, may provide fundamental information on paleoclimate, depositional environment, and the evolution of geological (e.g., volcanic and magmatic) systems. PMID:26694380