WorldWideScience

Sample records for administration transmission system

  1. Bonneville Power Administration Transmission System Vegetation Management Program - Final Environmental Impact Statement

    Energy Technology Data Exchange (ETDEWEB)

    N/A

    2000-06-23

    Bonneville is responsible for maintaining a network of 24,000 kilometers (km) or 15,000 miles (mi.) of electric transmission lines and 350 substations in a region of diverse vegetation. This vegetation can interfere with electric power flow, pose safety problems for us and the public, and interfere with our ability to maintain these facilities. We need to (1) keep vegetation away from our electric facilities; (2) increase our program efficiency and consistency; (3) review herbicide use (under increased public scrutiny); and (4) maximize the range of tools we can use while minimizing environmental impact (Integrated Vegetation Management). This Final Environmental Impact Statement (FEIS) establishes Planning Steps for managing vegetation for specific projects (to be tiered to this Environmental Impact Statement (EIS)). In addition to No Action (current practice), alternatives are presented for Rights-of-way, Electric Yards, and Non-electric Facilities (landscaping, work yards). Four vegetation control methods are analyzed manual, mechanical, herbicide, and biological. Also evaluated are 23 herbicide active ingredients and 4 herbicide application techniques (spot, localized, broadcast, and aerial). For rights-of-way, we consider three sets of alternatives: alternative management approaches (time-driven or establishing low-growing plant communities); alternative method packages; and, if herbicides are in a methods package, alternative vegetation selections (noxious weeds, deciduous, or any vegetation). For electric yards, one herbicide-use alternative is considered. For non-electric facilities, two method package alternatives are considered. For rights-of-way, the environmentally preferred alternative(s) would use manual, mechanical, and biological control methods, as well as spot and localized herbicide applications for noxious and deciduous plant species; the BPA-preferred alternative(s) would add broadcast and aerial herbicide applications, and would use herbicides

  2. Systemic administration of antiretrovirals prior to exposure prevents rectal and intravenous HIV-1 transmission in humanized BLT mice.

    Directory of Open Access Journals (Sweden)

    Paul W Denton

    Full Text Available Successful antiretroviral pre-exposure prophylaxis (PrEP for mucosal and intravenous HIV-1 transmission could reduce new infections among targeted high-risk populations including discordant couples, injection drug users, high-risk women and men who have sex with men. Targeted antiretroviral PrEP could be particularly effective at slowing the spread of HIV-1 if a single antiretroviral combination were found to be broadly protective across multiple routes of transmission. Therefore, we designed our in vivo preclinical study to systematically investigate whether rectal and intravenous HIV-1 transmission can be blocked by antiretrovirals administered systemically prior to HIV-1 exposure. We performed these studies using a highly relevant in vivo model of mucosal HIV-1 transmission, humanized Bone marrow/Liver/Thymus mice (BLT. BLT mice are susceptible to HIV-1 infection via three major physiological routes of viral transmission: vaginal, rectal and intravenous. Our results show that BLT mice given systemic antiretroviral PrEP are efficiently protected from HIV-1 infection regardless of the route of exposure. Specifically, systemic antiretroviral PrEP with emtricitabine and tenofovir disoproxil fumarate prevented both rectal (Chi square = 8.6, df = 1, p = 0.003 and intravenous (Chi square = 13, df = 1, p = 0.0003 HIV-1 transmission. Our results indicate that antiretroviral PrEP has the potential to be broadly effective at preventing new rectal or intravenous HIV transmissions in targeted high risk individuals. These in vivo preclinical findings provide strong experimental evidence supporting the potential clinical implementation of antiretroviral based pre-exposure prophylactic measures to prevent the spread of HIV/AIDS.

  3. Down hole transmission system

    Science.gov (United States)

    Hall, David R.; Hall, Jr., H. Tracy

    2007-07-24

    A transmission system in a downhole component comprises a data transmission element in both ends of the downhole component. Each data transmission element houses an electrically conducting coil in a MCEI circular trough. The electrically conducting coil comprises at least two generally fractional loops. In the preferred embodiment, the transmission elements are connected by an electrical conductor. Preferably, the electrical conductor is a coaxial cable. Preferably, the MCEI trough comprises ferrite. In the preferred embodiment, the fractional loops are connected by a connecting cable. In one aspect of the present invention, the connecting cable is a pair of twisted wires. In one embodiment the connecting cable is a shielded pair of twisted wires. In another aspect of the present invention, the connecting cable is a coaxial cable. The connecting cable may be disposed outside of the MCEI circular trough.

  4. Probabilistic transmission system planning

    CERN Document Server

    Li, Wenyuan

    2011-01-01

    "The book is composed of 12 chapters and three appendices, and can be divided into four parts. The first part includes Chapters 2 to 7, which discuss the concepts, models, methods and data in probabilistic transmission planning. The second part, Chapters 8 to 11, addresses four essential issues in probabilistic transmission planning applications using actual utility systems as examples. Chapter 12, as the third part, focuses on a special issue, i.e. how to deal with uncertainty of data in probabilistic transmission planning. The fourth part consists of three appendices, which provide the basic knowledge in mathematics for probabilistic planning. Please refer to the attached table of contents which is given in a very detailed manner"--

  5. Understanding land administration systems

    OpenAIRE

    P. Williamson, Ian; Enemark, Stig; Wallace, Judy; Rajabifard, Abbas

    2008-01-01

    This paper introduces basic land administration theory and highlights four key concepts that are fundamental to understanding modern land administration systems - firstly the land management paradigm and its influence on the land administration framework, secondly the role that the cadastre plays in contributing to sustainable development, thirdly the changing nature of ownership and the role of land markets, and lastly a land management vision that promotes land administration in support of ...

  6. Wireless data signal transmission system

    DEFF Research Database (Denmark)

    2014-01-01

    The present invention relates to a method for providing a radio frequency signal for transmission, a system for providing a radio frequency signal for transmission and a method for wireless data transmission between a transmitter and a receiver.......The present invention relates to a method for providing a radio frequency signal for transmission, a system for providing a radio frequency signal for transmission and a method for wireless data transmission between a transmitter and a receiver....

  7. NB Power Transmission system

    Energy Technology Data Exchange (ETDEWEB)

    Williamson, J. [NB Power Transmission, Fredericton, NB (Canada)

    2006-07-01

    The NB Power Transmission System operates 6700 km of transmission lines having voltages of 69 kV, 138 kV, 230 kV, and 345 kV. The history of lightning protection on this transmission system was presented. Lightning protection with shield wires has been applied selectively on the 69 kV and 138 kV lines and has been applied to all lines in the 230 kV and 345 kV range. Beginning in 2000, line arresters were installed on selected 69 kV and 138 kV lines. It was noted that although overhead shield wires are commonly installed to capture lightning strikes and shield the conductors, problems can occur if the electrical flashover of insulators result in a line to ground fault. Good grounding is needed to ensure that lightning enters the ground from the tower. The new approach is to install line arresters on structures without overhead shield wires. Line arresters are surge arresters applied in parallel with the insulator string. This new line arrester technology was tested by installing nearly 1200 arresters in the Saint John area. This paper described the reasons for choosing line arresters over shield wires and presented the methods of installation. The problems and failure rates of the installed line arresters were presented along with solutions, including solutions to protect lines against lightning in areas with heavy icing. Recommendations for future research into the use, application and development of line arresters were also presented. tabs., figs.

  8. ECRH transmission system

    International Nuclear Information System (INIS)

    The M.I.T. gyrotron group operates a 140 GHz, short pulse (1μs) gyrotron with output power, at present, of up to 175 kW. Output radiation has been obtained in several modes, including TE03 at 140 GHz, TE23 at 137 GHz, TE42 at 128 GHz and TE52 at 145 GHz. Studies have been carried out of the mode purity, both in frequency and in space, of gyrotron output radiation. These studies investigate parasitic mode excitation and mode conversion of gyrotron output power. Far field patterns of gyrotron radiation have been investigated to determine mode symmetry and purity. These results are useful in estimating the efficiency of various transmission systems. Finally, a new approach to quasi-optical transmission lines and mode converters, using axisymmetric optics, is suggested

  9. Understanding land administration systems

    DEFF Research Database (Denmark)

    P. Williamson, Ian; Enemark, Stig; Wallace, Judy;

    2008-01-01

    This paper introduces basic land administration theory and highlights four key concepts that are fundamental to understanding modern land administration systems. Readers may recall the first part of the paper in October issue of Coordinates. Here is the concluding part that focuses on the changing...... role of ownership and the role of land markets. Udgivelsesdato: November...

  10. Education of System Administration

    OpenAIRE

    Feyrer, Hubert

    2007-01-01

    This article discusses education of system administration. Theoretical foundations cover psychology, learning theory, instruction theory, and instructional design, leading to an ideal progression for education, and related tools. The main part describes an existing class on system administration as given at the University of Applied Sciences (Fachhochschule, FH) Regensburg, Germany. It is analyzed for its history and target audience, the current curriculum, course layout, and for the didac...

  11. Pro Python System Administration

    CERN Document Server

    Sileika, R

    2010-01-01

    As time goes on, system administrators are presented with increasingly complicated challenges. In the early days, a team of engineers might have had to look after one or two systems. These days, one engineer can administer hundreds or thousands of systems. System administrators are gradually replacing their tools with more advanced and flexible ones. One of the choices is Python. Structurally, Python is a modern, high-level language with a very clean syntax. Python comes with many built-in libraries that can make automation tasks easier. It also has extensive set of third-party libraries and a

  12. Linux System Administration

    CERN Document Server

    Adelstein, Tom

    2007-01-01

    If you're an experienced system administrator looking to acquire Linux skills, or a seasoned Linux user facing a new challenge, Linux System Administration offers practical knowledge for managing a complete range of Linux systems and servers. The book summarizes the steps you need to build everything from standalone SOHO hubs, web servers, and LAN servers to load-balanced clusters and servers consolidated through virtualization. Along the way, you'll learn about all of the tools you need to set up and maintain these working environments. Linux is now a standard corporate platform with user

  13. Understanding land administration systems

    DEFF Research Database (Denmark)

    P. Williamson, Ian; Enemark, Stig; Wallace, Judy;

    2008-01-01

    in contributing to sustainable development, thirdly the changing nature of ownership and the role of land markets, and lastly a land management vision that promotes land administration in support of sustainable development and spatial enablement of society. We present here the first part of the paper. The second...... part focuses on the changing  role of ownership and the role of land markets, and a land management vision will be published in November issue of Coordinates. Udgivelsesdato: Oktober......This paper introduces basic land administration theory and highlights four key concepts that are fundamental to understanding modern land administration systems - firstly the land management paradigm and its influence on the land administration framework, secondly the role that the cadastre plays...

  14. Land Administration Systems

    DEFF Research Database (Denmark)

    Enemark, Stig

    2014-01-01

    Land administration systems are the operational tool for conceptualizing rights, restrictions and responsibilities (RRRs) in land. Each of the rights, restrictions and responsibilities encompasses a human rights dimension that relates to the overall national land policies and should be unfolded as...... more than just rhetoric. This paper attempts to analyse the aspects of human rights in relation to land administration systems with a special focus on developing countries struggling to build adequate systems for governing the rights, restrictions and responsibilities in land. Human rights are the...... of being alive. Of special interest in relation to land and property is the right to own things and the right of food and adequate housing for all. More generally, human rights should be seen as an ethical responsibility of government to ensure that people enjoy some basic rights as human beings...

  15. ATLAS TDAQ System Administration:

    CERN Document Server

    Lee, Christopher Jon; The ATLAS collaboration; Bogdanchikov, Alexander; Ballestrero, Sergio; Contescu, Alexandru Cristian; Dubrov, Sergei; Fazio, Daniel; Korol, Aleksandr; Scannicchio, Diana; Twomey, Matthew Shaun; Voronkov, Artem

    2015-01-01

    The ATLAS Trigger and Data Acquisition (TDAQ) system is responsible for the online processing of live data, streaming from the ATLAS experiment at the Large Hadron Collider (LHC) at CERN. The online farm is composed of ̃3000 servers, processing the data readout from ̃100 million detector channels through multiple trigger levels. During the two years of the first Long Shutdown (LS1) there has been a tremendous amount of work done by the ATLAS TDAQ System Administrators, implementing numerous new software applications, upgrading the OS and the hardware, changing some design philosophies and exploiting the High Level Trigger farm with different purposes. During the data taking only critical security updates are applied and broken hardware is replaced to ensure a stable operational environment. The LS1 provided an excellent opportunity to look into new technologies and applications that would help to improve and streamline the daily tasks of not only the System Administrators, but also of the scientists who wil...

  16. Hybrid-Vehicle Transmission System

    Science.gov (United States)

    Lupo, G.; Dotti, G.

    1985-01-01

    Continuously-variable transmission system for hybrid vehicles couples internal-combustion engine and electric motor section, either individually or in parallel, to power vehicle wheels during steering and braking.

  17. Administrative closure methodology for the development of transmission projects

    Directory of Open Access Journals (Sweden)

    Denys Garcia

    2013-09-01

    Full Text Available ABSTRACTThe objective of this research was to propose a methodology for administrative closure of the transmission development projects in the electricity sector in Zulia state. It was classified as descriptive, considered feasible project and considering a methodology for the analysis and description of the variable studied. Likewise, the research design was non-experimental field, transactional and descriptive. The target population was 18 subjects, members of companies in the electricity sector State. The data collection technique used in this research was the survey instrument as a questionnaire, which was evaluated according to the Cronbach reliability coefficient, obtaining a score of 0.86, which puts you a high level of reliability. Through the evaluation of the results obtained in applying the instrument is able to diagnose the current situation in the closing phase of projects, resulting in a lower domain of the steps and elements needed to perform a proper shutdown. Therefore we designed a methodology which provides guidance for the administrative closure of the transmission development projects in the electricity sector in Zulia state, schematically and systematized, which comprises a set of discrete steps and aimed at strengthening and improvement issues identified opportunities to improve the process for closing projects.Keywords: Methodology, Administrative closure, Projects, Transmission, Development.

  18. Centos system administration essentials

    CERN Document Server

    Mallett, Andrew

    2014-01-01

    If you are a Linux administrator who is looking to gain knowledge that differentiates yourself from the crowd, then this is the book for you. Beginners who have a keen interest to learn more about Linux administration will also progress quickly with this resourceful learning guide.

  19. Functions Of Land Administration System

    OpenAIRE

    Oksana Sakal

    2012-01-01

    The theoretical basis and essence of some common and specific functions of land administration system as an integral mechanism of effective land use and land administration levels (case-study for forest and other land available for afforestation) are analysed.

  20. Ultrafast Transmission Systems using Coherent Technology

    DEFF Research Database (Denmark)

    Ludwig, Reinhold; Richter, Thomas; Palushani, Evarist;

    2011-01-01

    We review recent progress in ultrafast transmission systems. Using coherent detection for simultaneous demultiplexing and demodulation enabled single channel serial 10.2Tb/s transmission over 29km as well as transmission impairment compensation far beyond electronic speed limits.......We review recent progress in ultrafast transmission systems. Using coherent detection for simultaneous demultiplexing and demodulation enabled single channel serial 10.2Tb/s transmission over 29km as well as transmission impairment compensation far beyond electronic speed limits....

  1. CpG DNA facilitate the inactivated transmissible gastroenteritis virus in enhancing the local and systemic immune response of pigs via oral administration.

    Science.gov (United States)

    Lin, Jian; Tu, Chongzhi; Mou, Chunxiao; Chen, Xiaojuan; Yang, Qian

    2016-04-01

    Transmissible gastroenteritis virus (TGEV) replicates in the small intestine and induces enteritis and watery diarrhea. Establishment of local immunity in the intestine would thus prevent TGEV transmission. CpG DNA has been reported as a promising mucosal adjuvant in some animals. The effects of oral immunization of CpG DNA together with inactivated TGEV (ITGEV) were investigated in this study. Pigs (6 weeks old) were orally immunized with ITGEV plus CpG DNA. The TGEV-specific IgA level in the intestinal tract and the TGEV-specific IgG level in serum significantly increased following immunization with ITGEV plus CpG DNA (P ≤ 0.05). Moreover, populations of IgA-secreting cells, CD3+ T lymphocytes and intraepithelial lymphocytes (IELs), in the intestine increased significantly after immunization with ITGEV plus CpG DNA (P ≤ 0.05). Furthermore, the expression of IL-6, IL-12 and interferon-γ (IFN-γ) in ligated intestine segments increased significantly after injection with ITGEV plus CpG DNA (P ≤ 0.05). Taken together, these data suggest that oral immunization of ITGEV plus CpG DNA elicits a local immune response. Further studies are required to determine whether this immunity provides protection against TGEV in pigs. PMID:27032496

  2. ICT data transmission system based on UDP

    International Nuclear Information System (INIS)

    Recently, there are more detectors, longer transmission distance and larger amount of data in ICT transmission system. The traditional data transmission system is difficult to low cost, and at the same time satisfy the long-distance transmission and high-speed transmission. We have designed a kind of data transmission system, in which we used the UDP protocol and implemented in FPGA with verilog programming. Taking into account the low cost and at the same time we have coordinated the contradiction between long-distance and high speed transmission well. (authors)

  3. Transmission system planning in Ontario

    Energy Technology Data Exchange (ETDEWEB)

    Barrie, D.; Macedo, F.X.; Mcconnach, J.S. [Ontario Hydro, Toronto, ON (Canada)

    1994-12-31

    In recent years, new and modified approaches to planning the large transmission system that serves the province of Ontario, Canada, have been necessary to accommodate the rapidly changing planning environment including slower uncertain growth, ageing of facilities, integration of demand side management and non utility generation options, increased competitiveness, increased financial stresses and affordable constraints. This paper describes some of the new and modified approaches and tools that have been adopted or are being developed by Ontario Hydro to cope with this changing environment. (author) 9 refs., 4 figs.

  4. Harmonics in transmission power systems

    DEFF Research Database (Denmark)

    Wiechowski, Wojciech Tomasz

    , provided that background harmonic distortion, and the network configuration, are not changing during the measurement. It is shown that switching of a shunt linear power system component can result in variation of the harmonic levels that can be measured and used to verify the harmonic model of the network....... Three novel methods are also proposed, where switching of a series component can be used for the same purpose. Two of these methods are based on the determination of transfer harmonic impedance of the network and the third approach, which is actually used in the project, is based on injection......, in order to determine which power system component, when switched, results in the largest change in harmonic levels, some initial harmonic simulations, using the created harmonic model of Energinet.dk transmission network, are performed. The criterion is that the measuring equipment shall not be installed...

  5. CONTRACT ADMINISTRATIVE TRACKING SYSTEM (CATS)

    Science.gov (United States)

    The Contract Administrative Tracking System (CATS) was developed in response to an ORD NHEERL, Mid-Continent Ecology Division (MED)-recognized need for an automated tracking and retrieval system for Cost Reimbursable Level of Effort (CR/LOE) Contracts. CATS is an Oracle-based app...

  6. Fractional Frequency Transmission System and Its Applications

    Institute of Scientific and Technical Information of China (English)

    WANG Xifan; WANG Xiuli; TENG Yufei

    2012-01-01

    In 1994, we proposed transmission approach, the a novel fractional electricity frequency transmission system (FFTS), which uses lower frequency (50/3 Hz) to reduce the electrical length of AC power lines and thus obviously increases transmission capacity. The system is especially suitable to transmit remote renewable power such as hydro power and wind power.

  7. Game Changing Usage of High-Voltage Power Transmission Systems as Extremely Large Antennas for Space Physical and Geophysical Remote Imaging Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Geomagnetic storms drive geomagnetically induced currents (GIC) in high-voltage power transmission systems worldwide. GIC distribution in the transmission system is...

  8. Beta attenuation transmission system (BATS)

    Energy Technology Data Exchange (ETDEWEB)

    Hagan, R.C.; Fullbright, H.J.

    1977-01-01

    The beta attenuation transmission system (BATS) is an automated radiation gauge designed for quantitative measurement of component thickness in explosive detonators. The BATS was designed and built by Group M-1, the Nondestructive Testing Group, of the Los Alamos Scientific Laboratory to measure the areal thickness, in mg/cm/sup 2/, of a cylinder of high explosive (HE) enclosed within a plastic holder. The problem is to determine the density of the HE. A /sup 90/Sr source is collimated by a 0.25 x 1.59-mm slit, and the transmitted beta-particle flux is detected by a plastic scintillator, coupled to a photomultiplier tube. The detonator is transported through the radiation beam by a leadscrew, ballnut, stepping-motor combination. Continuous analog position data are available, derived from the output from a linear-actuated potentiometer attached to the scanner. A linear electrometer amplifies the detected signal, which is then integrated for a preselected time, to obtain the desired statistical accuracy. A microprocessor (..mu..P) is used to control the scanner position and to make the data readings at the assigned positions. The data are stored, and, at the completion of the scan, are processed into the desired format. The final answer is displayed to the operator or output to a peripheral device for permanent record. The characteristics of the radiation source, the collimator, the signal detection and conditioning, and the final results are described in detail. The scanner and the microprocessor control system are briefly outlined.

  9. RESEARCH OF DYNAMIC CHARACTERIATIC FOR TRANSMISSION SYSTEM

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The kinetic precision of transmission chain is a key problem in the research of gear cutting machine transmission system.The traditional point of view is to consider the transmission chain as a geometrical meshing system,thus it is deemed that the kinetic precision of the transmission chain only depends on the manufacturing and assembly errors of its transmission parts.But further research reveals that the kinetic precision of transmission system is closely related with the system dynamic effects.Therefore,from the dynamic point of view,it is discerned that not only deems the transmission chain as a geometrical meshing system but also considers it as a dynamic system performing with torsional vibration.On the basis of analyses and processes of measuring data of samples from tests of cutting machine's kinetic precision of transmission chain,the results represent that the influences of dynamic characteristics of the transmission system on its kinetic precision is non-negligible.Experimental methods for discerning the transfer function of torsional vibration of gear transmission system and experimental results have been given.

  10. INFORMATION IN THE SYSTEM OF STATE ADMINISTRATION

    OpenAIRE

    Kalytych, G.; Litosh, G.

    2009-01-01

    The article analyses the approaches to the notions of "information", "state administration system", "administrative information". The article considers the importance of of information for the whole state administration system and reveals the criteria which provide the information with administrative status. Special attention is paid to making of administrative decisions on the level of the sate which are based on effective information management.

  11. The Administration of Tax Systems

    OpenAIRE

    John Hasseldine

    2010-01-01

    This chapter analyses recent developments in tax administration and best practice. The chapter begins by contextualizing tax administration through a discussion on the necessary separation between the operational tasks performed in tax administration and the more generic, but nevertheless crucial, issues of organization, strategy and internal management required in tax administration. The chapter then describes the recent genesis and the current context of tax administration - especially in E...

  12. TWRS information locator database system administrator`s manual

    Energy Technology Data Exchange (ETDEWEB)

    Knutson, B.J., Westinghouse Hanford

    1996-09-13

    This document is a guide for use by the Tank Waste Remediation System (TWRS) Information Locator Database (ILD) System Administrator. The TWRS ILD System is an inventory of information used in the TWRS Systems Engineering process to represent the TWRS Technical Baseline. The inventory is maintained in the form of a relational database developed in Paradox 4.5.

  13. Software Architecture Patterns for System Administration Support

    OpenAIRE

    Bijvank, Ronald; Wiersema, Wiebe; Köppe, Christian

    2013-01-01

    Many quality aspects of software systems are addressed in the existing literature on software architecture patterns. But the aspect of system administration seems to be a bit overlooked, even though it is an important aspect too. In this work we present three software architecture patterns that, when applied by software architects, support the work of system administrators: PROVIDE AN ADMINISTRATION API, SINGLE FILE LOCATION, and CENTRALIZED SYSTEM LOGGING. PROVIDE AN ADMINISTRATION API shoul...

  14. Transmission Expansion Planning in Deregulated Power Systems

    OpenAIRE

    Oloomi Buygi, Majid

    2004-01-01

    The main goal of this thesis is to present a centralized static approach for transmission expansion planning in deregulated power systems. Restructuring and deregulation have unbundled the roles of network stakeholders. They exposed transmission planner to the new objectives and uncertainties. Unbundling the roles has brought new challenges for stakeholders. In these environments, stakeholders have different desires and expectations from the performance and expansion of the system. Therefore,...

  15. Methods, apparatus, and systems for monitoring transmission systems

    Energy Technology Data Exchange (ETDEWEB)

    Polk, Robert E; Svoboda, John M.; West, Phillip B.; Heath, Gail L.; Scott, Clark L.

    2016-07-19

    A sensing platform for monitoring a transmission system, and method therefor, may include a sensor that senses one or more conditions relating to a condition of the transmission system and/or the condition of an environment around the transmission system. A control system operatively associated with the sensor produces output data based on an output signal produced by the sensor. A transmitter operatively associated with the control system transmits the output data from the control system.

  16. Overview of remote data transmission systems

    Science.gov (United States)

    Paulson, Richard W.

    Remote data transmission systems for monitoring the environment are reviewed, including the Argos system, geostationary meteorological satellite systems, and the meteorburst technique which relies on micrometeor trails in the atmosphere to reflect radio messages between a hydrologic station and an interrogation site. The snow telemetry hydrologic data collection system, Landsat series of satellites, synchronous meteorological and geostationary operational environmental satellites are discussed. Specific elements of these systems are examined and major operators and users of the systems are identified.

  17. Transmission Assessment Surveys (TAS) to Define Endpoints for Lymphatic Filariasis Mass Drug Administration: A Multicenter Evaluation

    OpenAIRE

    Brian K Chu; Michael Deming; Nana-Kwadwo Biritwum; Bougma, Windtaré R.; Améyo M Dorkenoo; Maged El-Setouhy; Fischer, Peter U.; Katherine Gass; Manuel Gonzalez de Peña; Leda Mercado-Hernandez; Dominique Kyelem; Lammie, Patrick J; Rebecca M Flueckiger; Mwingira, Upendo J.; Rahmah Noordin

    2013-01-01

    BACKGROUND: Lymphatic filariasis (LF) is targeted for global elimination through treatment of entire at-risk populations with repeated annual mass drug administration (MDA). Essential for program success is defining and confirming the appropriate endpoint for MDA when transmission is presumed to have reached a level low enough that it cannot be sustained even in the absence of drug intervention. Guidelines advanced by WHO call for a transmission assessment survey (TAS) to determine if MDA can...

  18. Economics Of Optical Fibre Transmission Systems

    Science.gov (United States)

    Murray, W. J.

    1983-08-01

    Optical fibre as a telecommunication transmission medium has become one of the most significant developments so far of the digital era. A major contributory factor to the availability of optical fibre transmission systems has been the outstanding progress in the technology of manufacturing high quality glass fibre having relatively low attenuation and broad bandwidths. This and other achievements has enabled manufacturers in the United Kingdom to develop a range of optical fibre cables and transmission equipment for operation over short and long distances at the CCITT recommended digital hierarchical rates of 2, 8, 34 and 140Mbit/s which have been adopted by British Telecom (BT) for modernisation to an all digital transmission network. These optical fibre systems are now becoming increasingly price and performance competitive with conventional technology in many parts of telecommunications networks. In the British Telecom (BT) network the 140Mbit/s optical fibre systems are now economically competitive with equivalent systems on coaxial cable and microwave radio. The economics of 8 and 34Mbit/s systems are not yet sufficiently attractive, compared with 2Mbit/s digital line systems on pair type copper cables, for large scale use in rural and local distribution networks and are presently only justified on cost in and around large cities. As system costs decrease large applications are predicted particularly in support of future high speed data, cable television and visual information services.

  19. Eco-design of power transmissions systems

    International Nuclear Information System (INIS)

    The demand to preserve the environment and form a sustainable development is greatly increasing in the recent decades all over the world, and this environmental concern is also merged in electrical power industry, resulting in many eco-design approaches in Transmission and Distribution (T and D) industries. As a method of eco-design, Life Cycle Assessment (LCA) is a systematic tool that enables the assessment of the environmental impacts of a product or service throughout its entire life cycle, i.e. raw material production, manufacture, distribution, use and disposal including all intervening transportation steps necessary or caused by the product's existence. In T and D industries, LCA has been done for a lot of products individually, in order to see one product's environmental impacts and to seek for ways of improving its environmental performance. This eco-design for product approach is a rather well-developed trend, however, as only a single electrical product cannot provide the electrical power to users, electrical system consists of a huge number of components, in order to investigate system's environmental profile, the entire environmental profiles of different composing products has to be integrated systematically, that is to say, a system approach is needed. Under this philosophy, the study 'Eco-design of Power Transmission Systems' is conducted in this thesis, with the purpose of analysing the transmission systems' environmental impacts, locating the major environmental burden sources of transmission systems, selecting and/or developing methodologies of reducing its environmental impacts. (author)

  20. Global dynamic modeling of a transmission system

    Science.gov (United States)

    Choy, F. K.; Qian, W.

    1993-01-01

    The work performed on global dynamic simulation and noise correlation of gear transmission systems at the University of Akron is outlined. The objective is to develop a comprehensive procedure to simulate the dynamics of the gear transmission system coupled with the effects of gear box vibrations. The developed numerical model is benchmarked with results from experimental tests at NASA Lewis Research Center. The modal synthesis approach is used to develop the global transient vibration analysis procedure used in the model. Modal dynamic characteristics of the rotor-gear-bearing system are calculated by the matrix transfer method while those of the gear box are evaluated by the finite element method (NASTRAN). A three-dimensional, axial-lateral coupled bearing model is used to couple the rotor vibrations with the gear box motion. The vibrations between the individual rotor systems are coupled through the nonlinear gear mesh interactions. The global equations of motion are solved in modal coordinates and the transient vibration of the system is evaluated by a variable time-stepping integration scheme. The relationship between housing vibration and resulting noise of the gear transmission system is generated by linear transfer functions using experimental data. A nonlinear relationship of the noise components to the fundamental mesh frequency is developed using the hypercoherence function. The numerically simulated vibrations and predicted noise of the gear transmission system are compared with the experimental results from the gear noise test rig at NASA Lewis Research Center. Results of the comparison indicate that the global dynamic model developed can accurately simulate the dynamics of a gear transmission system.

  1. Global dynamic modeling of a transmission system

    Science.gov (United States)

    Choy, F. K.; Qian, W.

    1993-04-01

    The work performed on global dynamic simulation and noise correlation of gear transmission systems at the University of Akron is outlined. The objective is to develop a comprehensive procedure to simulate the dynamics of the gear transmission system coupled with the effects of gear box vibrations. The developed numerical model is benchmarked with results from experimental tests at NASA Lewis Research Center. The modal synthesis approach is used to develop the global transient vibration analysis procedure used in the model. Modal dynamic characteristics of the rotor-gear-bearing system are calculated by the matrix transfer method while those of the gear box are evaluated by the finite element method (NASTRAN). A three-dimensional, axial-lateral coupled bearing model is used to couple the rotor vibrations with the gear box motion. The vibrations between the individual rotor systems are coupled through the nonlinear gear mesh interactions. The global equations of motion are solved in modal coordinates and the transient vibration of the system is evaluated by a variable time-stepping integration scheme. The relationship between housing vibration and resulting noise of the gear transmission system is generated by linear transfer functions using experimental data. A nonlinear relationship of the noise components to the fundamental mesh frequency is developed using the hypercoherence function. The numerically simulated vibrations and predicted noise of the gear transmission system are compared with the experimental results from the gear noise test rig at NASA Lewis Research Center. Results of the comparison indicate that the global dynamic model developed can accurately simulate the dynamics of a gear transmission system.

  2. The Systemic Acquis of Public Administration

    OpenAIRE

    Matei, Ani; Lucica MATEI

    2002-01-01

    The “systemic acquis” wording revalorises the concepts used in building the European Union. By similarity with these, the public administration’s systemic acquis will include the concepts, theories and fundamental results belonging to the General Theory of Systems and applying to the administrative systems. For the public administration, their systemic acquis will also grasp a specific of their evolution and manifestation. The social systemic, mainly developed by the French specialised school...

  3. Transmission assessment surveys (TAS) to define endpoints for lymphatic filariasis mass drug administration

    DEFF Research Database (Denmark)

    Chu, Brian K.; Deming, Michael; Biritwum, Nana-Kwadwo;

    2013-01-01

    Lymphatic filariasis (LF) is targeted for global elimination through treatment of entire at-risk populations with repeated annual mass drug administration (MDA). Essential for program success is defining and confirming the appropriate endpoint for MDA when transmission is presumed to have reached...

  4. International Benchmarking of Electricity Transmission System Operators

    DEFF Research Database (Denmark)

    Agrell, Per J.; Bogetoft, Peter

    2014-01-01

    Electricity transmission system operators (TSO) in Europe are increasing subject to high-powered performance-based regulation, such as revenue-cap regimes. The determination of the parameters in such regimes is challenging for national regulatory authorities (NRA), since there is normally a single...

  5. Wireless Transmission System for Vehicle Inspection Data

    Institute of Scientific and Technical Information of China (English)

    LIU Yuan; MIAO Chang-yun

    2008-01-01

    Based on general packet radio service(GPRS) and TCP/IP protocol, a wireless transmission system of vehicle inspection data is designed. Basic structure and work theory are expounded. SIM300 designed by SIMCOM is used for client GPRS communication module. Using Winsock control of visual basic(VB), the client and server communication has been accomplished. By means of a client and server communications software, the remote wireless transmission of vehicle inspection data has been accomplished also. The server management software has been developed by using Microsoft SQL Server 2000 and VB6.0. Functions of software include import, inquiry, export and maintenance of test data.

  6. Genetic Algorithm Based Transmission Expansion Planning System

    Directory of Open Access Journals (Sweden)

    Dike, Damian Obioma

    2014-11-01

    Full Text Available This paper presents an application of genetic algorithm (GA to the solution of Static Transmission Expansion Planning (STEP to determine the optimal number of transmission circuits required in each network corridor and their respective network adequacy while satisfying various economic and technical constraints. The uncertainties in generation and distribution networks as a result of power system deregulation cannot be modeled effectively using the conventional mathematical methods. GA, been a probabilistic based approach has the ability to resolve the transmission expansion planning problem in the face of such uncertainties. The model presented in this work will help in the identification of overloaded lines using Gauss Seidel (GS load flow technique. Result from GS is then used as input in the GA simulation to show the extra lines needed to accommodate present load flow in the system. The model was tested on IEEE 14 – bus test network.The model developed and simulation results obtained may be useful in an electric power systems undergoing deregulation. Such is the case in Nigeria presently where the generation and distribution components are increasing significantly without any commensurate boost in the transmission sector. This leads to line overloads necessitating commensurate and immediate expansion of the grid

  7. Transmission techniques for 4G systems

    CERN Document Server

    Da Silva, Mario Marques

    2012-01-01

    Fourth Generation (4G) wireless communication systems support current and emergent multimedia services such as mobile TV, social networks and gaming, high-definition TV, video teleconferencing, and messaging services. These systems feature the All-over-IP concept and boast improved quality of service. Several important R&D activities are currently under way in the field of wireless communications for 4G systems, but the coverage is widespread in the literature. Transmission Techniques for 4G Systems presents a compilation of the latest developments in the field of wireless communications for 4

  8. Imports, exports, and Alberta's transmission system impact on price fluctuation

    International Nuclear Information System (INIS)

    The roles, responsibilities and objectives of ESBI, a private for-profit company, appointed by the Alberta Government to be the Independent Transmission Administrator in the province, is sketched, prior to a discussion of price volatility in electricity, Alberta interconnections, intertie issues, the economic theory and the reality impact on prices. Given that imports and exports constitute a relatively small proportion of total generation or load in Alberta, price volatility is considered to have been only minimally affected by imports/exports. In contrast, transmission constraints, i.e. the limits on physical capacity of the existing transmission system to accommodate all desired transactions, have significant impact on imports/exports. Factors underlying constraints and price volatility such as uncertainty of generation dispatch, leading to reduced interest to invest, which in turn leads to scarce capacity for imports/exports, and the actions required to reduce uncertainty and address other issues such as congestion management, tariff design and the creation of regional transmission organizations, are also discussed to provide further clarification of the issues. It is suggested that these and other related issues need to be resolved to provide the clarity around transmission access and the tools required to manage price fluctuations

  9. Cessation of mass drug administration for lymphatic filariasis in Zanzibar in 2006: was transmission interrupted?

    Directory of Open Access Journals (Sweden)

    Maria P Rebollo

    2015-03-01

    Full Text Available Lymphatic filariasis (LF is targeted for elimination through annual mass drug administration (MDA for 4-6 years. In 2006, Zanzibar stopped MDA against LF after five rounds of MDA revealed no microfilaraemic individuals during surveys at selected sentinel sites. We asked the question if LF transmission was truly interrupted in 2006 when MDA was stopped.In line with ongoing efforts to shrink the LF map, we performed the WHO recommended transmission assessment surveys (TAS in January 2012 to verify the absence of LF transmission on the main Zanzibar islands of Unguja and Pemba. Altogether, 3275 children were tested on both islands and 89 were found to be CFA positive; 70 in Pemba and 19 in Unguja. The distribution of schools with positive children was heterogeneous with pronounced spatial variation on both islands. Based on the calculated TAS cut-offs of 18 and 20 CFA positive children for Pemba and Unguja respectively, we demonstrated that transmission was still ongoing in Pemba where the cut-off was exceeded.Our findings indicated ongoing transmission of LF on Pemba in 2012. Moreover, we presented evidence from previous studies that LF transmission was also active on Unguja shortly after stopping MDA in 2006. Based on these observations the government of Zanzibar decided to resume MDA against LF on both islands in 2013.

  10. Flexible AC transmission systems modelling and control

    CERN Document Server

    Zhang, Xiao-Ping; Pal, Bikash

    2012-01-01

    The extended and revised second edition of this successful monograph presents advanced modeling, analysis and control techniques of Flexible AC Transmission Systems (FACTS). The book covers comprehensively a range of power-system control problems: from steady-state voltage and power flow control, to voltage and reactive power control, to voltage stability control, to small signal stability control using FACTS controllers. In the six years since the first edition of the book has been published research on the FACTS has continued to flourish while renewable energy has developed into a mature and

  11. Switching in electrical transmission and distribution systems

    CERN Document Server

    Smeets, René; Kapetanovic, Mirsad; Peelo, David F; Janssen, Anton

    2014-01-01

    Switching in Electrical Transmission and Distribution Systems presents the issues and technological solutions associated with switching in power systems, from medium to ultra-high voltage. The book systematically discusses the electrical aspects of switching, details the way load and fault currents are interrupted, the impact of fault currents, and compares switching equipment in particular circuit-breakers. The authors also explain all examples of practical switching phenomena by examining real measurements from switching tests. Other highlights include: up to date commentary on new develo

  12. Debian 7 system administration best practices

    CERN Document Server

    Pollei, Rich

    2013-01-01

    A step-by-step, example-based guide to learning how to install and administer the Debian Linux distribution.Debian 7: System Administration Best Practices is for users and administrators who are new to Debian, or for seasoned administrators who are switching to Debian from another Linux distribution. A basic knowledge of Linux or UNIX systems is useful, but not strictly required. Since the book is a high level guide, the reader should be willing to go to the referenced material for further details and practical examples.

  13. Python for Unix and Linux system administration

    CERN Document Server

    Gift, Noah

    2007-01-01

    Python is an ideal language for solving problems, especially in Linux and Unix networks. With this pragmatic book, administrators can review various tasks that often occur in the management of these systems, and learn how Python can provide a more efficient and less painful way to handle them. Each chapter in Python for Unix and Linux System Administration presents a particular administrative issue, such as concurrency or data backup, and presents Python solutions through hands-on examples. Once you finish this book, you'll be able to develop your own set of command-line utilities with Pytho

  14. Information System for Educational Policy and Administration.

    Science.gov (United States)

    Clayton, J. C., Jr.

    Educational Information System (EIS) is a proposed computer-based data processing system to help schools solve current educational problems more efficiently. The system would allow for more effective administrative operations in student scheduling, financial accounting, and long range planning. It would also assist school trustees and others in…

  15. System Administrator for LCS Development Sets

    Science.gov (United States)

    Garcia, Aaron

    2013-01-01

    The Spaceport Command and Control System Project is creating a Checkout and Control System that will eventually launch the next generation of vehicles from Kennedy Space Center. KSC has a large set of Development and Operational equipment already deployed in several facilities, including the Launch Control Center, which requires support. The position of System Administrator will complete tasks across multiple platforms (Linux/Windows), many of them virtual. The Hardware Branch of the Control and Data Systems Division at the Kennedy Space Center uses system administrators for a variety of tasks. The position of system administrator comes with many responsibilities which include maintaining computer systems, repair or set up hardware, install software, create backups and recover drive images are a sample of jobs which one must complete. Other duties may include working with clients in person or over the phone and resolving their computer system needs. Training is a major part of learning how an organization functions and operates. Taking that into consideration, NASA is no exception. Training on how to better protect the NASA computer infrastructure will be a topic to learn, followed by NASA work polices. Attending meetings and discussing progress will be expected. A system administrator will have an account with root access. Root access gives a user full access to a computer system and or network. System admins can remove critical system files and recover files using a tape backup. Problem solving will be an important skill to develop in order to complete the many tasks.

  16. Highly Efficient Contactless Electrical Energy Transmission System

    Science.gov (United States)

    Ayano, Hideki; Nagase, Hiroshi; Inaba, Hiromi

    This paper proposes a new concept for a contactless electrical energy transmission system for an elevator and an automated guided vehicle. The system has rechargeable batteries on the car and electrical energy is supplied at a specific place. When electric power is supplied to the car, it runs automatically and approaches the battery charger. Therefore, a comparatively large gap is needed between the primary transformer at the battery charger and the secondary transformer on the car in order to prevent damage which would be caused by a collision. In this case, a drop of the transformer coupling rate due to the large gap must be prevented. In conventional contactless electrical energy transmission technology, since electric power is received by a pick-up coil from a power line, a large-sized transformer is required. And when the distance over which the car runs is long, the copper loss of the line also increases. The developed system adopts a high frequency inverter using a soft switching method to miniaturize the transformer. The system has a coupling rate of 0.88 for a transformer gap length of 10mm and can operate at 91% efficiency.

  17. Insulation systems for superconducting transmission cables

    DEFF Research Database (Denmark)

    Tønnesen, Ole

    1996-01-01

    the electrical insulation is placed outside both the superconducting tube and the cryostat. The superconducting tube is cooled by liquid nitrogen which is pumped through the hollow part of the tube.2) The cryogenic dielectric design, where the electrical insulation is placed inside the cryostat and thus is kept......This paper describes shortly the status of superconducting transmission lines and assesses what impact the recently discovered BSCCO superconductors may have on the design of the cables.Two basically different insulation systems are discussed:1) The room temperature dielectric design, where...

  18. Software Architecture Patterns for System Administration Support

    NARCIS (Netherlands)

    Bijvank, Ronald; Wiersema, Wiebe; Köppe, Christian

    2013-01-01

    Many quality aspects of software systems are addressed in the existing literature on software architecture patterns. But the aspect of system administration seems to be a bit overlooked, even though it is an important aspect too. In this work we present three software architecture patterns that, whe

  19. A Stream Control Transmission Protocol Based OAM System of 3G Cellular Network

    Institute of Scientific and Technical Information of China (English)

    2005-01-01

    OAM (Operations, Administration and Maintenance) system is a very important component of 3G cellular network. In order to acquire overall management, fast response and steady operation, an SCTP (Stream Control Transmission Protocol) based OAM, i. e. , SOAM system was proposed. SOAM implements new characters of SCTP such as multi-stream, enforced SACK and heartbeat mechanism on its transport layer. These characters help SOAM decrease the message transmission delay and accelerate the link failure detection. Besides, a new component named SOAM agent was introduced to improve the operation efficiency of SOAM. The experimental results prove the proposed SOAM system achieves better performance on signaling transmission compared with conventional TCP based OAM system.

  20. Land Administration Systems in Transition Countries

    Directory of Open Access Journals (Sweden)

    Mario Mađer

    2011-06-01

    Full Text Available The paper contains an analysis of land administration systems in transition countries on the example of South Eastern European countries. An analysis of regulation on registration of real estate registration and rights was done in addition to the comparison of institutions and jurisdictions. Also an analysis of registers of real estates and real estate rights has been done and their main features listed. The paper provides insight into some of the technological achievements in the field of improvement and modernization of land administration systems.

  1. Flexible AC transmission systems: the state of the art

    Energy Technology Data Exchange (ETDEWEB)

    Edris, Abdel-Aty [Electric Power Research Inst., Palo Alto, CA (United States). Electric Systems Division

    1994-12-31

    Flexible AC transmission systems (FACTS) is a concept promoting the use of power electronic controllers to enhance the controllability and usable capacity of AC transmission. This paper presents the state of the art of FACTS and the status of the current projects for the application of the FACTS controllers in transmission systems. (author) 8 refs., 8 figs.

  2. Transmission Interference Improvement of Railway Communication via Distributed Antennas System.

    OpenAIRE

    Lin, Siyu; Zhong , Zhangdui; Ai, Bo; Briso Rodriguez, Cesar

    2010-01-01

    Transmission interference is a key performance indicator of railway digital mobile communication system(RDMCS), whose performance will become worse in high-speed railway. The factors that influence the transmission interference of RDMCS are analyzed. Based on the relationship between speed and transmission interference, the scheme based on distributed antennas system (DAS) is proposed to improve transmission interference of RDMCS. The proposed scheme can reduce the collision probability betwe...

  3. Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-142- KeelerOregon City #2)

    Energy Technology Data Exchange (ETDEWEB)

    Barndt, Shawn L. [Bonneville Power Administration, Portland, OR (United States)

    2003-04-04

    Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-142- KeelerOregon #2). Bonneville Power Administration proposes to remove vegetation alongside Transmission Right-of-Ways

  4. TMACS Test Procedure TP007: System administration

    International Nuclear Information System (INIS)

    The TMACS Software Project Test Procedures translate the project's acceptance criteria into test steps. Software releases are certified when the affected Test Procedures are successfully performed and the customers authorize installation of these changes. This Test Procedure tests the TMACS System Administration functions

  5. Microfluidic system for transmission electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Ring, Elisabeth A [ORNL; De Jonge, Niels [ORNL

    2010-01-01

    We present a microfluidic system that maintains liquid flow in a specimen chamber for (scanning) transmission electron microscope ((S)TEM) imaging. The specimen chamber consists of two ultra-thin silicon nitride windows supported by silicon microchips. They are placed in a specimen holder that seals the sample from the vacuum in the electron microscope, and incorporates tubing to and from the sample connected to a syringe pump outside the microscope. Using results obtained from fluorescence microscopy of microspheres flowing through the system, an equation to characterize the liquid flow through the system was calibrated. Gold nanoparticles of diameters of 30 and 100 nm moving in liquid were imaged with a 200 kV STEM. It was concluded that despite strong influences from Brownian motion, and sensitivity to small changes in the depth of the bypass channel, the electron microscopy flow data matched the calculated flow speed within an order of magnitude. The system allows for rapid (within a minute) liquid exchange, which can potentially be used, for example, to investigate the response of specimens, e.g., eukaryotic-, or bacterial cells, to certain stimuli.

  6. Classification of the MGR Administration System

    International Nuclear Information System (INIS)

    The purpose of this analysis is to document the Quality Assurance (QA) classification of the Monitored Geologic Repository (MGR) administration system structures, systems and components (SSCs) performed by the MGR Safety Assurance Department. This analysis also provides the basis for revision of YMP/9O-55Qy Q-List (YMP 1998). The Q-List identifies those MGR SSCs subject to the requirements of DOE/RW-0333P, ''Quality Assurance Requirements and Description'' (QARD) (DOE 1998)

  7. New Comparison of HVDC and HVAC Transmission system

    Directory of Open Access Journals (Sweden)

    Vahid Behravesh

    2012-06-01

    Full Text Available Alternating current (AC is the main driving force in the industries and residential areas, but for the long transmission line (more than 400 miles AC transmission is more expensive than that of direct current (DC. Technically, AC transmission line control is more complicated because of the frequency. DC transmission does not have these limitations, which has led to build long HVDC transmission lines over the last 40 years. HVDC technology made possible to transfer bulk power over long distances. This paper presents a comparative evaluation of HVDC and HVAC transmission systems .

  8. Development of the Field of Flexible AC Transmission Systems (FACTS)

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    @@ Theoretical and technological development of large capacity power electronics and flexible AC transmission systems are one of the most important projects developed by Tsinghua University. The Flexible AC Transmission System (FACTS) technology which uses power electronics to improve the efficiency and quality of the electrical generation, transmission and distribution system is considered to be one of the most significant technological innovations for power systems in the 20th century. The advanced static var generator (ASVG) is a key FACTS device.

  9. Commercial information system of Slovak Electricity Transmission System, Plc

    International Nuclear Information System (INIS)

    Commercial Information System (CIS), which main role of is to support the commercial activities of the company, is built up by business department of SEPS, Plc in close co-operation with the supplier company Sfera, Plc. The system entries are data from electricity meters obtained by automatized data acquisition and from bugging sheets, contractual hour diagrams, parameters of transmission system like measuring schemes and formulas for calculation of demand and supply, contractual data resulting from agreements, business conditions, URSO decisions and valid legislative. A part of the system is also support of process of data evaluation like calculation of transmitted energy quantity, calculation of actual output diagrams, comparison of actual and contractual diagrams, calculation of system divergence, calculation of demand divergence, etc. The final price for the drawings of services, which are joined with transmission of the electric power will be determined by the accounting process. In this causality there are automatically made out invoices for access, losses, system charges, system services, short-term and long-term transits, divergences and for cross-border transmission auctions. System also generates various specialized synopses and statistics for the evaluation requirements of important aspects and for parameter observations. Successive liberalisation of the electricity power market, changes in legislative and URSO decisions require CIS to be sufficiently configurable and to adapt flexible on the alternating environs. (author)

  10. Electricity transmission line planning: Success factors for transmission system operators to reduce public opposition

    OpenAIRE

    Perras, Stefan

    2015-01-01

    Europe requires significant transmission grid expansions to foster the integration of electricity markets, enhance security of supply and integrate renewable energies. However, next to lengthy authorization processes, transmission system operators (TSOs) in Europe are currently facing extreme public opposition in their transmission line projects leading to significant project delays. These delays imply significant additional costs for TSOs as well as society as a whole and put the transformat...

  11. INFORMATION-MEASURING TEST SYSTEM OF DIESEL LOCOMOTIVE HYDRAULIC TRANSMISSIONS

    OpenAIRE

    ZHUKOVYTSKYY I.V.; KLIUSHNYK I.A.; OCHKASOV O.B.; KORENIYK R.O.

    2015-01-01

    Purpose. The article describes the process of developing the information-measuring test system of diesel locomotives hydraulic transmission, which gives the possibility to obtain baseline data to conduct further studies for the determination of the technical condition of diesel locomotives hydraulic transmission. The improvement of factory technology of post-repair tests of hydraulic transmissions by automating the existing hydraulic transmission test stands according to the specifications of...

  12. The Architecture and Administration of the ATLAS Online Computing System

    CERN Document Server

    Dobson, M; Ertorer, E; Garitaonandia, H; Leahu, L; Leahu, M; Malciu, I M; Panikashvili, E; Topurov, A; Ünel, G; Computing In High Energy and Nuclear Physics

    2006-01-01

    The needs of ATLAS experiment at the upcoming LHC accelerator, CERN, in terms of data transmission rates and processing power require a large cluster of computers (of the order of thousands) administrated and exploited in a coherent and optimal manner. Requirements like stability, robustness and fast recovery in case of failure impose a server-client system architecture with servers distributed in a tree like structure and clients booted from the network. For security reasons, the system should be accessible only through an application gateway and, also to ensure the autonomy of the system, the network services should be provided internally by dedicated machines in synchronization with CERN IT department's central services. The paper describes a small scale implementation of the system architecture that fits the given requirements and constraints. Emphasis will be put on the mechanisms and tools used to net boot the clients via the "Boot With Me" project and to synchronize information within the cluster via t...

  13. Field tests of the Liberty-Mead transmission system

    Energy Technology Data Exchange (ETDEWEB)

    Eilts, L.E.

    1979-08-01

    Summarized are results of the October 1977 field tests of the 383-km(238-mi), 345-kV, series-capacitor-compensated Liberty-Mead transmission line of the Western Area Power Administration. The test series included routine capacitor bypass and insertion tests, line switching tests, and staged-fault tests. Principal results are presented in several figures, tables, and oscillograms. The tests demonstrated that routine capacitor bypass and insertion do not adversely affect the power system; line switching surges are modest, but reclosing, using the existing switchgear, is precluded by trapped charge; high-speed capacitor bypass was achieved but reinsertion proceeded slower than permitted by the specifications; breaker interrupting performance was acceptable; and, excepting some minor problems that were identified, the line relaying schemes generally performed satisfactorily.

  14. Land Administration Systems in Transition Countries

    OpenAIRE

    Mario Mađer; Miodrag Roić

    2011-01-01

    The paper contains an analysis of land administration systems in transition countries on the example of South Eastern European countries. An analysis of regulation on registration of real estate registration and rights was done in addition to the comparison of institutions and jurisdictions. Also an analysis of registers of real estates and real estate rights has been done and their main features listed. The paper provides insight into some of the technological achievements in the field of im...

  15. Transmission Assessment Surveys (TAS) to Define Endpoints for Lymphatic Filariasis Mass Drug Administration: A Multicenter Evaluation

    Science.gov (United States)

    Chu, Brian K.; Deming, Michael; Biritwum, Nana-Kwadwo; Bougma, Windtaré R.; Dorkenoo, Améyo M.; El-Setouhy, Maged; Fischer, Peter U.; Gass, Katherine; Gonzalez de Peña, Manuel; Mercado-Hernandez, Leda; Kyelem, Dominique; Lammie, Patrick J.; Flueckiger, Rebecca M.; Mwingira, Upendo J.; Noordin, Rahmah; Offei Owusu, Irene; Ottesen, Eric A.; Pavluck, Alexandre; Pilotte, Nils; Rao, Ramakrishna U.; Samarasekera, Dilhani; Schmaedick, Mark A.; Settinayake, Sunil; Simonsen, Paul E.; Supali, Taniawati; Taleo, Fasihah; Torres, Melissa; Weil, Gary J.; Won, Kimberly Y.

    2013-01-01

    Background Lymphatic filariasis (LF) is targeted for global elimination through treatment of entire at-risk populations with repeated annual mass drug administration (MDA). Essential for program success is defining and confirming the appropriate endpoint for MDA when transmission is presumed to have reached a level low enough that it cannot be sustained even in the absence of drug intervention. Guidelines advanced by WHO call for a transmission assessment survey (TAS) to determine if MDA can be stopped within an LF evaluation unit (EU) after at least five effective rounds of annual treatment. To test the value and practicality of these guidelines, a multicenter operational research trial was undertaken in 11 countries covering various geographic and epidemiological settings. Methodology The TAS was conducted twice in each EU with TAS-1 and TAS-2 approximately 24 months apart. Lot quality assurance sampling (LQAS) formed the basis of the TAS survey design but specific EU characteristics defined the survey site (school or community), eligible population (6–7 year olds or 1st–2nd graders), survey type (systematic or cluster-sampling), target sample size, and critical cutoff (a statistically powered threshold below which transmission is expected to be no longer sustainable). The primary diagnostic tools were the immunochromatographic (ICT) test for W. bancrofti EUs and the BmR1 test (Brugia Rapid or PanLF) for Brugia spp. EUs. Principal Findings/Conclusions In 10 of 11 EUs, the number of TAS-1 positive cases was below the critical cutoff, indicating that MDA could be stopped. The same results were found in the follow-up TAS-2, therefore, confirming the previous decision outcome. Sample sizes were highly sex and age-representative and closely matched the target value after factoring in estimates of non-participation. The TAS was determined to be a practical and effective evaluation tool for stopping MDA although its validity for longer-term post-MDA surveillance

  16. An embedded Video Transmission System Based on H.264

    Institute of Scientific and Technical Information of China (English)

    GAO Jing-min; LAN Ya-zhu

    2009-01-01

    In this paper,an embedded Video Transmission System based on H.264 is proposed.In this system,the latest video compression standards-H.264 is used as video codec algorithm,the i.mx27 is used as the center processors of the system,embedded Linux is used as the operating system and RTP/UDP is used as the network transmission protocol.The paper introduces the design way and the frame of the system.The test results of the system show that the proposed system can support good quality transmission of the video information.The parameters with the transmission are D1,720*480,30fps and 4Mbps.In addition,in order to ensure the security of the video information in the transmission,the system provides the encryption to the information in the process of compressing.

  17. Transmission techniques for emergent multicast and broadcast systems

    CERN Document Server

    da Silva, Mario Marques; Dinis, Rui; Souto, Nuno; Silva, Joao Carlos

    2010-01-01

    Describing efficient transmission schemes for broadband wireless systems, Transmission Techniques for Emergent Multicast and Broadcast Systems examines advances in transmission techniques and receiver designs capable of supporting the emergent wireless needs for multimedia broadcast and multicast service (MBMS) requirements. It summarizes the research and development taking place in wireless communications for multimedia MBMS and addresses the means to improved spectral efficiency to allow for increased user bit rate, as well as increased capacity of the digital cellular radio network.The text

  18. Lymphatic Filariasis control in Tanzania:effect of repeated mass drug administration with Ivermectin and Albendazole on infection and transmission

    OpenAIRE

    Simonsen, Paul Erik; Pedersen, Erling Møller; Rwegoshora, Rwehumbiza T.; Malecela, Mwelecele N.; Derua, Yahya A; Magesa, Stephen M

    2010-01-01

    Background In most countries of sub-Saharan Africa the control of lymphatic filariasis (LF) is based on annual mass drug administration (MDA) with a combination of ivermectin and albendazole, in order to interrupt transmission. Here we present the first detailed study on the effect of 3 repeated MDAs with this drug combination, as implemented by the Tanzanian National Lymphatic Filariasis Elimination Programme (NLFEP). Methodology/Principal Findings Infection and transmission was monitored du...

  19. 47 CFR 73.875 - Modification of transmission systems.

    Science.gov (United States)

    2010-10-01

    ... transmission system facilities. (a) The following changes are prohibited: (1) Those that would result in the.... (2) Those that would cause the transmission system to exceed the equipment performance measurements... test operations at the full authorized ERP may commence immediately upon installation pursuant to §...

  20. 7 CFR 400.209 - Electronic transmission and receiving system.

    Science.gov (United States)

    2010-01-01

    ... Contract-Standards for Approval § 400.209 Electronic transmission and receiving system. Any Contractor under the Contract is required to: (a) Adopt a plan for the purpose of transmitting and receiving... 7 Agriculture 6 2010-01-01 2010-01-01 false Electronic transmission and receiving system....

  1. Nonlinear system guidance in the presence of transmission zero dynamics

    Science.gov (United States)

    Meyer, G.; Hunt, L. R.; Su, R.

    1995-01-01

    An iterative procedure is proposed for computing the commanded state trajectories and controls that guide a possibly multiaxis, time-varying, nonlinear system with transmission zero dynamics through a given arbitrary sequence of control points. The procedure is initialized by the system inverse with the transmission zero effects nulled out. Then the 'steady state' solution of the perturbation model with the transmission zero dynamics intact is computed and used to correct the initial zero-free solution. Both time domain and frequency domain methods are presented for computing the steady state solutions of the possibly nonminimum phase transmission zero dynamics. The procedure is illustrated by means of linear and nonlinear examples.

  2. 40 Gb/s optical transmission systems

    DEFF Research Database (Denmark)

    Buxens Azcoaga, Alvaro Juan; Nielsen, Steen Krogh

    2003-01-01

    application (maximum distance of 40 km) the maximum PMD coeficient allowed in the transmission fiber, 0.4 ps=pkm, is below the values defined by actual standards, 0.5 ps=pkm. The most promising PMD compensation methods are presented and their advantages and disadvantages are discussed. A PMD compensator based...

  3. MIMO Identical Eigenmode Transmission System (IETS) - a Channel Decomposition Perspective

    OpenAIRE

    Shakir, Muhammad Zeeshan; Durrani, Tariq

    2007-01-01

    In the past few years considerable attention has been given to the design of Multiple-Input Multiple-Output (MIMO) Eigenmode Transmission Systems (EMTS). This paper presents an in-depth analysis of a new MIMO eigenmode transmission strategy. The non-linear decomposition technique called Geometric Mean Decomposition (GMD) is employed for the formation of eigenmodes over MIMO flatfading channel. Exploiting GMD technique, identical, parallel and independent transmission pipes are created for dat...

  4. Underwater Acoustic Image Transmission System Based on DSP

    Institute of Scientific and Technical Information of China (English)

    Cheng En; Xu Ru

    2002-01-01

    The underwater acoustic image transmission system based on the high-speed DSP device TMS320C549 has been studied. We use Goertzel algorithm for source decoding and MFSK for modulation. Turbo code is used for channel coding and decoding. The purpose is to implement underwater video image data transmission.

  5. Distance Protection of Cross-Bonded Transmission Cable-Systems

    DEFF Research Database (Denmark)

    Bak, Claus Leth; F. Jensen, Christian

    2014-01-01

    In this paper the problems of protecting a cross-bonded cable system using distance protection are analysed. The combination of the desire to expand the high voltage transmission grid and the public's opinion towards new installations of overhead lines (OHL), more and more transmission cable syst...

  6. FPGA Implementation of Video Transmission System Based on LTE

    OpenAIRE

    Lu Yan; Zhang Qianlong; Tang An

    2015-01-01

    In order to support high-definition video transmission, an implementation of video transmission system based on Long Term Evolution is designed. This system is developed on Xilinx Virtex-6 FPGA ML605 Evaluation Board. The paper elaborates the features of baseband link designed in Xilinx ISE and protocol stack designed in Xilinx SDK, and introduces the process of setting up hardware and software platform in Xilinx XPS. According to test, this system consumes less hardware resource and is able ...

  7. Determination of Transmission Limits on Electric Power Systems

    Directory of Open Access Journals (Sweden)

    Castellanos-Bustamante Rafael

    2014-04-01

    Full Text Available This article provides the application of several methodologies to obtain power transmission limits through interties of the electric power systems to obtain a secure operation of the energy power system. Several aspects to obtain the maximum power flows of electrical energy thought of transmission lines on electrical grids are shown. Thermal limit of electrical conductors, loadability limit of transmission lines and small signal stability limits are obtained for several interties between geographical regions. It also, shows the application of a load shedding scheme to stabilize an interarea oscillation mode. The model of the Mexican Interconnected power System is used to illustrate these methodologies.

  8. INFORMATION-MEASURING TEST SYSTEM OF DIESEL LOCOMOTIVE HYDRAULIC TRANSMISSIONS

    Directory of Open Access Journals (Sweden)

    I. V. Zhukovytskyy

    2015-08-01

    Full Text Available Purpose. The article describes the process of developing the information-measuring test system of diesel locomotives hydraulic transmission, which gives the possibility to obtain baseline data to conduct further studies for the determination of the technical condition of diesel locomotives hydraulic transmission. The improvement of factory technology of post-repair tests of hydraulic transmissions by automating the existing hydraulic transmission test stands according to the specifications of the diesel locomotive repair enterprises was analyzed. It is achieved based on a detailed review of existing foreign information-measuring test systems for hydraulic transmission of diesel locomotives, BelAZ earthmover, aircraft tug, slag car, truck, BelAZ wheel dozer, some brands of tractors, etc. The problem for creation the information-measuring test systems for diesel locomotive hydraulic transmission is being solved, starting in the first place from the possibility of automation of the existing test stand of diesel locomotives hydraulic transmission at Dnipropetrovsk Diesel Locomotive Repair Plant "Promteplovoz". Methodology. In the work the researchers proposed the method to create a microprocessor automated system of diesel locomotives hydraulic transmission stand testing in the locomotive plant conditions. It acts by justifying the selection of the necessary sensors, as well as the application of the necessary hardware and software for information-measuring systems. Findings. Based on the conducted analysis there was grounded the necessity of improvement the plant hydraulic transmission stand testing by creating a microprocessor testing system, supported by the experience of developing such systems abroad. Further research should be aimed to improve the accuracy and frequency of data collection by adopting the more modern and reliable sensors in tandem with the use of filtering software for electromagnetic and other interference. Originality. The

  9. Automatic Voltage Control (AVC) of Danish Transmission System - Concept design

    DEFF Research Database (Denmark)

    Qin, Nan; Abildgaard, Hans; Lund, P.;

    2014-01-01

    . Another consequence is the public way of generally thinking green which have led to a national decision of undergrounding not only all of the Danish distribution system but also the future transmission system. These issues initiate the infrastructure constructions of the transmission system i.e. a large...... amount of overhead lines over 100 kV as well as the new planed transmission lines will be undergrounded; the transfer capacities will be enlarged by upgrading the interconnections. Large amounts of reactive power components will be placed in the system partly for cable compensation and partly for voltage...... the substation loses the telecommunications to the control center. RPCs will be integrated to the AVC system as normative regulators in the later stage. Distributed generation units can be organized as virtual power plants and participate in voltage control at transmission level. Energinet.dk as the Danish TSO...

  10. Forward error correction in DWDM fiber-optic transmission system

    OpenAIRE

    Gol, V. D.; Tsmykal, E. K.

    2009-01-01

    In this paper we consider options of antinoise coding application in DWDM fiber-optic transmission systems, and also we represent comparative analysis of predicting correction, defining by G.975.1 recommendation regarding correction possibility and redundancy.

  11. Italian power transmission systems. Decision making and operations

    International Nuclear Information System (INIS)

    The models adopted in Italy for management maintenance and development of national transmission system foresee a manager with a decision making rule and owners who operate physically on the electric power network

  12. Vibration transmissibility characteristics of smart spring vibration isolation system

    Institute of Scientific and Technical Information of China (English)

    倪德; 朱如鹏; 陆凤霞; 鲍和云; 付秋菊

    2014-01-01

    The objective of this work was to study the vibration transmissibility characteristics of the undamped and damped smart spring systems. The frequency response characteristics of them were analyzed by using the equivalent linearization technique, and the possible types of the system motion were distinguished by using the starting and ending frequencies. The influences of system parameters on the vibration transmissibility characteristics were discussed. The following conclusions may be drawn from the analysis results. The undamped smart spring system may simultaneously have one starting frequency and one ending frequency or only have one starting frequency, and the damped system may simultaneously have two starting frequencies and one ending frequency. There is an optimal control parameter to make the peak value of the vibration transmissibility curve of the system be minimum. When the mass ratio is far away from the stiffness ratio, the vibration transmissibility is small. The effect of the damping ratio on the system vibration transmissibility is significant while the control parameter is less than its optimal value. But the influence of the relative damping ratio on the vibration transmissibility is small.

  13. On the transmissibilities of nonlinear vibration isolation system

    Science.gov (United States)

    Lu, Zeqi; Brennan, Michael J.; Chen, Li-Qun

    2016-08-01

    Transmissibility is a key parameter to quantify the effectiveness of a vibration isolation system. Under harmonic excitation, the force transmissibility of a linear vibration isolation system is defined as the ratio between the amplitude of the force transmitted to the host structure and the excitation force amplitude, and the displacement transmissibility is the ratio between the displacement amplitude of the payload and that of the base. For a nonlinear vibration isolation system, the force or the displacement responses usually have more frequency components than the excitation. For a harmonic excitation, the response may be periodic, quasi-periodic or chaotic. Therefore, the amplitude ratio cannot well define the transmissibility. The root-mean-square ratio of the response to the excitation is suggested to define the transmissibility. The significance of the modified transmissibility is highlighted in a nonlinear two-stage vibration isolation system consisting of two linear spring connected linear vibration isolators with two additional horizontal linear springs. Harmonic balance method (HBM) is applied to determine the responses with the fundamental and third harmonic. Numerical simulations reveal that chaos may occur in the responses. In both cases, the modified transmissibility works while the original definition cannot be applied to chaotic response.

  14. The Italian Administrative System: Why a Source of Competitive Disadvantage?

    OpenAIRE

    Magda Bianco; Giulio Napolitano

    2011-01-01

    The Italian administrative system is currently perceived as one of the main obstacles to a higher growth of the productive system. We argue that some causes of this ineffectiveness are deeply rooted and date back at the unification: a missing strong administrative tradition; an (excessive) political influence over the administration; the relevance of the juridical culture. We discuss in detail one specific "product" of the administration, its civil justice system, its inefficiencies over time...

  15. Alternative electrical transmission systems and their environmental impact

    Energy Technology Data Exchange (ETDEWEB)

    Schiefelbein, G.F.

    1977-08-01

    A general description is provided of electrical transmission systems as an aid in determining their environmental impacts. Alternating current, direct current, overhead systems, underground systems, and water crossings are treated. The cost, performance, reliability, safety, and environmental impact of these systems are compared.

  16. Investigating and Implementing a DNS Administration System

    OpenAIRE

    Brännström, Anders; Nilsson, Rickard

    2007-01-01

    NinetechGruppen AB is an IT service providing company with about 30 employees, primarily based in Karlstad, Sweden. The company began to have problems with their DNS administration because the number of administrated domains had grown too large. A single employee was responsible for all the administration, and text editors were used for modifying the DNS configuration files directly on the name servers. This was an error prone process which also easily led to inconsistencies between the docum...

  17. Cost estimation of HVDC transmission system of Bangka's NPP candidates

    Science.gov (United States)

    Liun, Edwaren; Suparman

    2014-09-01

    Regarding nuclear power plant development in Bangka Island, it can be estimated that produced power will be oversupply for the Bangka Island and needs to transmit to Sumatra or Java Island. The distance between the regions or islands causing considerable loss of power in transmission by alternating current, and a wide range of technical and economical issues. The objective of this paper addresses to economics analysis of direct current transmission system to overcome those technical problem. Direct current transmission has a stable characteristic, so that the power delivery from Bangka to Sumatra or Java in a large scale efficiently and reliably can be done. HVDC system costs depend on the power capacity applied to the system and length of the transmission line in addition to other variables that may be different.

  18. Systems engineering design for operations directorate administrative information system

    OpenAIRE

    Hasegawa, Marnie Tardieu

    1994-01-01

    This project addresses an administrative information system for the Operations Directorate (0D) within federal government agency (which is referred to as the "Agency"). The OD was formed two years ago to combine similar tasks under one directorate. When the 00 was formed there was insufficient time to properly address the information system and many of the OD personnel did not have a clear understanding of their own functional requirements. Now two years later, the OD manage...

  19. HIV Transmission in a State Prison System, 1988–2005

    OpenAIRE

    Krishna Jafa; Peter McElroy; Lisa Fitzpatrick; Borkowf, Craig B.; Robin Macgowan; Andrew Margolis; Ken Robbins; Ae Saekhou Youngpairoj; Dale Stratford; Alan Greenberg; Jennifer Taussig; R Luke Shouse; Madeleine Lamarre; Eleanor McLellan-Lemal; Walid Heneine

    2009-01-01

    INTRODUCTION: HIV prevalence among state prison inmates in the United States is more than five times higher than among nonincarcerated persons, but HIV transmission within U.S. prisons is sparsely documented. We investigated 88 HIV seroconversions reported from 1988-2005 among male Georgia prison inmates. METHODS: We analyzed medical and administrative data to describe seroconverters' HIV testing histories and performed a case-crossover analysis of their risks before and after HIV diagnosis. ...

  20. Long-lasting insecticidal nets are synergistic with mass drug administration for interruption of lymphatic filariasis transmission in Nigeria.

    Directory of Open Access Journals (Sweden)

    Abel Eigege

    Full Text Available In central Nigeria Anopheles mosquitoes transmit malaria and lymphatic filariasis (LF. The strategy used for interrupting LF transmission in this area is annual mass drug administration (MDA with albendazole and ivermectin, but after 8 years of MDA, entomological evaluations in sentinel villages showed continued low-grade mosquito infection rates of 0.32%. After long-lasting insecticidal net (LLIN distribution by the national malaria program in late 2010, however, we were no longer able to detect infected vectors over a 24-month period. This is evidence that LLINs are synergistic with MDA in interrupting LF transmission.

  1. Long-Lasting Insecticidal Nets Are Synergistic with Mass Drug Administration for Interruption of Lymphatic Filariasis Transmission in Nigeria

    Science.gov (United States)

    Eigege, Abel; Miri, Emmanuel; Sallau, Adamu; Umaru, John; Mafuyai, Hayward; Chuwang, Yohanna S.; Danjuma, Goshit; Danboyi, Jacob; Adelamo, Solomon E.; Mancha, Bulus S.; Okoeguale, Bridget; Patterson, Amy E.; Rakers, Lindsay; Richards, Frank O.

    2013-01-01

    In central Nigeria Anopheles mosquitoes transmit malaria and lymphatic filariasis (LF). The strategy used for interrupting LF transmission in this area is annual mass drug administration (MDA) with albendazole and ivermectin, but after 8 years of MDA, entomological evaluations in sentinel villages showed continued low-grade mosquito infection rates of 0.32%. After long-lasting insecticidal net (LLIN) distribution by the national malaria program in late 2010, however, we were no longer able to detect infected vectors over a 24-month period. This is evidence that LLINs are synergistic with MDA in interrupting LF transmission. PMID:24205421

  2. Reform and Development of Educational Administration System in China

    Science.gov (United States)

    Li, Qiang; Wu, Zhongyuan

    2008-01-01

    The paper mainly introduces the development of the educational administration agency in China, including the evolution of the educational administration agency, the Course of instituting legal system of education in China, the missions of the now Minister of Education, questions emerged in the development of the educational administration system,…

  3. 78 FR 65641 - Recommendation From the Western Area Power Administration To Pursue Regional Transmission...

    Science.gov (United States)

    2013-11-01

    ... Area Power Administration, 2900 4th Avenue North, Billings, MT 59101-1266. FOR FURTHER INFORMATION... Administration, 2900 4th Avenue North, Billings, MT 59101-1266, telephone (406) 255- 2910, email sundsted@wapa....gov/ugp/Environment/default.htm . Dated: October 29, 2013. Mark A. Gabriel, Administrator....

  4. Unequal error protection system for robust video transmission

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    With the development of multimedia communication services, robust video transmission over wireless environment poses many challenges. A new UEP_ BTC _ STBC _ OFDM system is proposed to provide unequal error protection for the source coded video stream in dispersive fading channel. The scheme concatenates the Block Turbo Code (BTC) with the Space-Time Block Code (STBC) for an OFDM system.With the proposed system, both the good error correcting capability of BTC and the concurrent large diversity gain characteristic of STBC can be achieved simultaneously with low encoding and decoding complexity. Furthermore, by combining with the data partition of H. 264 and different BTC codes, this system can guarantee high QoS control of video transmission. Simulation result shows that the proposed system outperforms other reported schemes and has good performance of video transmission.

  5. Optimal Transmission Power in a Nonlinear VLC System

    Institute of Scientific and Technical Information of China (English)

    ZHAO Shuang; CAI Sunzeng; KANG Kai; QIAN Hua

    2016-01-01

    In a visible light communication (VLC) system, the light emitting diode (LED) is nonlinear for large signals, which limits the trans⁃mission power or equivalently the coverage of the VLC system. When the input signal amplitude is large, the nonlinear distortion creates harmonic and intermodulation distortion, which degrades the transmission error vector magnitude (EVM). To evaluate the impact of nonlinearity on system performance, the signal to noise and distortion ratio (SNDR) is applied, defined as the linear sig⁃nal power over the thermal noise plus the front end nonlinear distortion. At a given noise level, the optimal system performance can be achieved by maximizing the SNDR, which results in high transmission rate or long transmission range for the VLC system. In this paper, we provide theoretical analysis on the optimization of SNDR with a nonlinear Hammerstein model of LED. Simula⁃tion results and lab experiments validate the theoretical analysis.

  6. Optimisation of Video-Data Transmission in Telematic System

    OpenAIRE

    Emilia Bubenikova; Peter Holecko; Rastislav Pirnik

    2013-01-01

    The goal of this paper is to analyse, define, and summarise the requirements on networks connecting telematic technologies based on Intelligent Transport Systems (ITS). The paper describes the methodics of setting and a general concept of technological networks interface based on available and applicable standards Focus is set on optimisation of data transmission in the form of a video-stream and its tunnelling through xDSL transmission technology. The implementation of the designed compres...

  7. Optimisation of video-data transmission in telematic system

    OpenAIRE

    Bubeníková, Emília; Pirník, Rastislav; Holečko, Peter

    2013-01-01

    The goal of this paper is to analyse, define, and summarise the requirements on networks connecting telematic technologies based on Intelligent Transport Systems (ITS). The paper describes the methodics of setting and a general concept of technological networks interface based on available and applicable standards Focus is set on optimisation of data transmission in the form of a video-stream and its tunnelling through xDSL transmission technology. The implementation of the designed compressi...

  8. Investigating CVT as a Transmission System Option for Wind Turbines

    OpenAIRE

    Alkan, Deniz

    2013-01-01

    In this study, an innovative solution is examined for transmission problems and frequency control for wind Turbines. Power electronics and the gear boxes are the parts which are responsible of a significant amount of failures and they are increasing the operation and maintenance cost of wind turbines. Continuously transmission (CVT) systems are investigated as an alternative for conventional gear box technologies for wind turbines in terms of frequency control and power production efficiency....

  9. Career Analysis in the Public Administration System

    OpenAIRE

    Morariu Alunica

    2013-01-01

    Considered to be the professional history of an individual, the career is one of the most important issues the contemporary organizations are facing, be it from the public or private environment. The Romanian public administration reform in the recent years also aimed the human resources of the central or local public institutions and authorities. It has made its presence felt, either through legislative changes or by creating new tools for human resource management in public administration. ...

  10. Comparative analysis of tax administration system in Russian regions

    Directory of Open Access Journals (Sweden)

    Aleksey Sergeevich Naydenov

    2011-09-01

    Full Text Available This paper presents the results of the study on tax administration attractiveness for taxpayers in the Russian Federation. The authors provide an overview of existing approaches to understanding the nature of the tax administration. To solve the problem of estimating the attractiveness of the tax administration in this study, we proposed a methodological approach based on comparative analysis of the rank of territorial systems of tax administration. In the basis of comparative analysis is the calculation of a set of indicators that characterize the tax administration system attractiveness from the standpoint of the taxpayer, with subsequent calculation of integral indexes and rankings of the Russian Federation. The results assessing the attractiveness of the tax administration system in the regions are shown. In this paper, we attempt to assess modern tax administration as one of the key economic institutions, as well as to obtain quantitative data on the status of the tax administration in Russia's regions.

  11. Power transmission from offshore wind generation systems

    Energy Technology Data Exchange (ETDEWEB)

    Franklin, P.J.; Gardner, G.E.

    1981-01-01

    Since wind power appears to be one of the more cost effective alternative energy sources the problems of integrating it into the supply system are being examined in some detail. A basic array is considered which has 14*14 aerogenerators with down and cross wind spacings of 10 propeller diameters thereby covering an area of 64 km/sup 2/, giving an average energy recovery efficiency for the array of 81%. The electrical connections are examined, and the stability of the systems to faults within the cluster is discussed. 3 refs.

  12. Conceptualizing the European Multilevel Administrative Order. Capturing variation in the European administrative system

    OpenAIRE

    Trondal, Jarle; Bauer, Michael W

    2014-01-01

    Departing from the observation that both analysts and practitioners face problems of meaningful categorization of social order in general and the European political-administrative system in particular, this paper suggests a conceptual frame through which European administrative order may be understood. Providing such a frame is important, because the catalogue of categories of the European Union (EU) polity developed so far fails to acknowledge sufficiently its administrative dimension. Given...

  13. FPGA Implementation of Video Transmission System Based on LTE

    Directory of Open Access Journals (Sweden)

    Lu Yan

    2015-01-01

    Full Text Available In order to support high-definition video transmission, an implementation of video transmission system based on Long Term Evolution is designed. This system is developed on Xilinx Virtex-6 FPGA ML605 Evaluation Board. The paper elaborates the features of baseband link designed in Xilinx ISE and protocol stack designed in Xilinx SDK, and introduces the process of setting up hardware and software platform in Xilinx XPS. According to test, this system consumes less hardware resource and is able to transmit bidirectional video clearly and stably.

  14. Modern Systems of Information Transmission on Agro & Food Supply Chain

    Directory of Open Access Journals (Sweden)

    Silvius STANCIU

    2011-11-01

    Full Text Available Global food commodity diversification requires the application of new methods of data identification, monitoring, collection and processing in the production or distribution area. Classical systems of information transmission are currently widely used, but also present some inconvenience addressed by the emergence of new generations of information carriers. Current requirements for technical processes monitoring, quality assurance, traceability and customer orientation led to the emergence and evolution of modern identification systems based on dynamic information transmission and global databases development. The development of computer technology and the Internet are factors that allowed the development of these systems.

  15. Tidal current turbine based on hydraulic transmission system

    Institute of Scientific and Technical Information of China (English)

    Hong-wei LIU; Wei LI; Yong-gang LIN; Shun MA

    2011-01-01

    Tidal current turbines (TCTs) are newly developed electricity generating devices.Aiming at the stabilization of the power output of TCTs,this paper introduces the hydraulic transmission technologies into TCTs.The hydrodynamics of the turbine was analyzed at first and its power output characteristics were predicted.A hydraulic power transmission system and a hydraulic pitch-controlled system were designed.Then related simulations were conducted.Finally,a TCT prototype was manufactured and tested in the workshop.The test results have confirmed the correctness of the current design and availability of installation of the hydraulic system in TCTs.

  16. Wireless OAM transmission system based on elliptical microstrip patch antenna.

    Science.gov (United States)

    Chen, Jia Jia; Lu, Qian Nan; Dong, Fei Fei; Yang, Jing Jing; Huang, Ming

    2016-05-30

    The multiplexing transmission has always been a focus of attention for communication technology. In this paper, the radiation characteristics of circular microstrip patch antenna was firstly analyzed based on cavity model theory, and then spiral beams carrying orbital angular momentum (OAM) were generated, using elliptical microstrip patch antenna, with a single feed probe instead of a standard circular patch with two feedpoints. Moreover, by combining the proposed elliptic microstrip patch antenna with Universal Software Radio Peripheral (USRP), a wireless OAM transmission system was established and the real-time transmission of text, image and video in a real channel environment was realized. Since the wireless OAM transmission has the advantage of good safety and high spectrum utilization efficiency, this work has theoretical significance and potential application. PMID:27410080

  17. Creating a robust and integrated electrical transmission system

    International Nuclear Information System (INIS)

    The service territory for Puget Sound Energy (PSE) was presented in terms of electric power and gas transmission. Issues affecting the Puget Sound area include high growth and the west coast energy crisis which has had an adverse financial impact on the power industry. The transmission system is basically at capacity and has been impacted by imports and exports between the United States and Canada. Other issues include the separation between energy resources and transmission, modernizing the power grid, and challenges for independent power producers (IPPs). The Northwest Transmission Assessment Committee (NTAC), which was formed under the Northwest Power Pool, has the potential to bring interested parties to study constrained paths and to plan a single utility concept for the region. It is expected that new challenges such as financing and risk management will emerge once the technical solutions are identified and agreed upon. The issue of enforceable and mandatory reliability standards was also discussed. 1 fig

  18. Tier-2 system administration: a comprehensive approach

    International Nuclear Information System (INIS)

    Liverpool is consistently amongst the top Tier-2 sites in Europe in terms of efficiency and cluster utilisation. This paper will cover the work performed at Liverpool over the last six years to maximise and maintain efficiency and productivity at their Tier 2 site, with an overview of the tools used (including established, emerging, and locally developed solutions) for monitoring, testing, installation, configuration, ticketing, logging, and administration, along with the techniques for management, operations, and optimisation that tie them together into a comprehensive, scalable, and sustainable approach to Tier 2 administration.

  19. Design of data transmission for a portable DAQ system

    International Nuclear Information System (INIS)

    Field Programmable Gate Array (FPGA), combined with ARM (Advanced RISC Machines) is increasingly employed in the portable data acquisition (DAQ) system for nuclear experiments to reduce the system volume and achieve powerful and multifunctional capacity. High-speed data transmission between FPGA and ARM is one of the most challenging issues for system implementation. In this paper, we propose a method to realize the high-speed data transmission by using the FPGA to acquire massive data from FEE (Front-end electronics) and send it to the ARM whilst the ARM to transmit the data to the remote computer through the TCP/IP protocol for later process. This paper mainly introduces the interface design of the high-speed transmission method between the FPGA and the ARM, the transmission logic of the FPGA, and the program design of the ARM. The theoretical research shows that the maximal transmission speed between the FPGA and the ARM through this way can reach 50 MB/s. In a realistic nuclear physics experiment, this portable DAQ system achieved 2.2 MB/s data acquisition speed. (authors)

  20. On-Line Administrative Information Systems: A Case Study.

    Science.gov (United States)

    Sire, Paul W.

    A case study approach is used to document the on-line information system developed by the Office of Management Information and Computing at the University of Vermont. Stanford University's Project INFO On-Line Administration Information System, OASIS, was chosen as a model. The administrative system is one of two on campus, the other designed for…

  1. Concept of Educationional and Administrative Processes Automation System for Department

    OpenAIRE

    Ivan N. Berlinets

    2012-01-01

    Article describes concept and approach to implementation of educational and administrative processes automation system for graduate department. Described program components and technologies implementing system’s functions

  2. Development of an advanced transmission line fault location system

    International Nuclear Information System (INIS)

    This paper describes the solution techniques, system modeling considerations, and simulation studies performed as a part of the development of an advanced transmission line fault location system (AFLS) intended for use on the New York Power Authority's system. The Power Authority's Moses-Adirondack 230 kV lines were selected as a test bed for the study. A reduced model of the transmission system around the Moses-Adirondack lines was developed, and a number of Electromagnetic Transients Program (EMTP) cases run to establish simulated voltage and current information as fed to the fault location system. Sensitivity studies were performed to investigate the impact of various system models, hardware features, and system conditions on fault location accuracy

  3. Stokes Space in Direct-Detection Data Transmission Systems

    DEFF Research Database (Denmark)

    Estaran Tolosa, Jose Manuel; Lu, Xiaofeng; Zibar, Darko;

    2015-01-01

    Stokes-based processing permits complete and phase-insensitive characterization of the field’s SOP, readily unlocking polarization diversity in transmission systems where DD is desired. We present an overview on Stokes notions and most recent achievements in this context.......Stokes-based processing permits complete and phase-insensitive characterization of the field’s SOP, readily unlocking polarization diversity in transmission systems where DD is desired. We present an overview on Stokes notions and most recent achievements in this context....

  4. Technology for extending transmission distance of EPON system

    Institute of Scientific and Technical Information of China (English)

    Li ZHANG; Deming LIU; Cbuanbao ZHANG; Guangsbeng WU

    2009-01-01

    At present, the maximal transmission distance between the optical line terminal (OLT) and opticalnetwork unit (ONU) of an Ethemet passive optical network (EPON) system is 20 km.However, this distance should be extended to 50 km or even longer in some applications such as fiber to the village (FTTV).A method for extending the transmission distance of an EPON system is proposed in this paper, in which the optical power amplifier and the adjustment of dynamic bandwidth allocation (DBA) are the key technologies.

  5. A Proposal on Low Frequency AC Transmission as a Multi-Terminal Transmission System

    Directory of Open Access Journals (Sweden)

    Achara Pichetjamroen

    2016-08-01

    Full Text Available This paper is focused on the discussion and comparison of characteristics and behavior of three low frequency ac (LFAC transmission system configurations operating under the same control scheme and conditions to identify the most promising operation system for LFAC. Merits of LFAC over high voltage direct current (HVDC are mentioned first. By changing power flow direction without auxiliary switches in multi-terminal application and easiness of short circuit protection are explained. The three configurations of LFACs are described and applied by the control scheme with the aid of the tool of the PSCAD/EMTDC software to consider the behavior of each LFAC system on line frequency and low frequency sides. For two-phase system, no fluctuation occurs on the line frequency side, which is the advantage over single-phase system. Furthermore, current rating on thyristor devices during operation and number of devices that used in each type of LFAC are calculated and compared. These results can lead to determine the most suitable transmission system for the LFAC system operation.

  6. HIV transmission in a state prison system, 1988-2005.

    Directory of Open Access Journals (Sweden)

    Krishna Jafa

    Full Text Available INTRODUCTION: HIV prevalence among state prison inmates in the United States is more than five times higher than among nonincarcerated persons, but HIV transmission within U.S. prisons is sparsely documented. We investigated 88 HIV seroconversions reported from 1988-2005 among male Georgia prison inmates. METHODS: We analyzed medical and administrative data to describe seroconverters' HIV testing histories and performed a case-crossover analysis of their risks before and after HIV diagnosis. We sequenced the gag, env, and pol genes of seroconverters' HIV strains to identify genetically-related HIV transmission clusters and antiretroviral resistance. We combined risk, genetic, and administrative data to describe prison HIV transmission networks. RESULTS: Forty-one (47% seroconverters were diagnosed with HIV from July 2003-June 2005 when voluntary annual testing was offered. Seroconverters were less likely to report sex (OR [odds ratio] = 0.02, 95% CI [confidence interval]: 0-0.10 and tattooing (OR = 0.03, 95% CI: <0.01-0.20 in prison after their HIV diagnosis than before. Of 67 seroconverters' specimens tested, 33 (49% fell into one of 10 genetically-related clusters; of these, 25 (76% reported sex in prison before their HIV diagnosis. The HIV strains of 8 (61% of 13 antiretroviral-naïve and 21 (40% of 52 antiretroviral-treated seroconverters were antiretroviral-resistant. DISCUSSION: Half of all HIV seroconversions were identified when routine voluntary testing was offered, and seroconverters reduced their risks following their diagnosis. Most genetically-related seroconverters reported sex in prison, suggesting HIV transmission through sexual networks. Resistance testing before initiating antiretroviral therapy is important for newly-diagnosed inmates.

  7. The Education System in the Public Administration

    OpenAIRE

    Sedláčková, Lucie

    2012-01-01

    Summary This diploma thesis deals with education of employees in administration concentrating on a specific sector. The aim of this thesis is to suggest changes in educational processes within the Police of the Czech Republic taking into account an analysis of the results. Afterwards the thesis defines the input of suggested solutions. The subject of inquiries for this thesis is the regional head office of Vysocina region, which employs both civil service and police service employees....

  8. A New Design of Video Streaming Capture and Transmission System

    Directory of Open Access Journals (Sweden)

    Xingyu Geng

    2014-10-01

    Full Text Available Aiming to solve some existing problems such as low video streaming rate, high cost and complex set-up, a new video streaming capture and transmission system based on servfox is proposed. This system uses servfox to invoke V4L APIs to capture video streaming in Linux operating system, and then transmits the data to a remote monitoring client through Internet which can display the video streaming. Remote client can be either a software or a web browser. The experimental results show that the image captured by this system is high-quality and the streaming rate is high. At the same time, the system possesses high reliability and low cost. Compared with existing methods, this system can be widely used in the process of video streaming capture and transmission

  9. A miniaturized digital telemetry system for physiological data transmission

    Science.gov (United States)

    Portnoy, W. M.; Stotts, L. J.

    1978-01-01

    A physiological date telemetry system, consisting basically of a portable unit and a ground base station was designed, built, and tested. The portable unit to be worn by the subject is composed of a single crystal controlled transmitter with AM transmission of digital data and narrowband FM transmission of voice; a crystal controlled FM receiver; thirteen input channels follwed by a PCM encoder (three of these channels are designed for ECG data); a calibration unit; and a transponder control system. The ground base station consists of a standard telemetry reciever, a decoder, and an FM transmitter for transmission of voice and transponder signals to the portable unit. The ground base station has complete control of power to all subsystems in the portable unit. The phase-locked loop circuit which is used to decode the data, remains in operation even when the signal from the portable unit is interrupted.

  10. Medical data transmission system for remote healthcare centres

    International Nuclear Information System (INIS)

    The main motivation of this project is to improve the healthcare centres equipment and human resources efficiency, enabling those centres for transmission of parameters of medical interest. This system facilitates remote consultation, in particular between specialists and remote healthcare centres. Likewise it contributes to the qualification of professionals. The electrocardiographic (ECG) and electroencephalographic (EEG) signals are acquired, processed and then sent, fulfilling the effective norms, for application in the hospital network of Cordoba Province, which has nodes interconnected by phone line. As innovative aspects we emphasized the low cost of development and maintenance, great versatility and handling simplicity with a modular design for interconnection with diverse data transmission media (Wi-Fi, GPRS, etc.). Successfully experiences were obtained during the acquisition of the signals and transmissions on wired LAN networks. As improvements, we can mention: energy consumption optimization and mobile communication systems usage, in order to offer more autonomy

  11. The education system in the selected organization of public administration - Customs administration of the Czech republic

    OpenAIRE

    Komůrková, Gabriela

    2014-01-01

    The thesis is focused on the education system, the Customs Administration of the Czech Republic. The aim of the study was to determine overall satisfaction with education, the Customs Administration of the Czech Republic and suggest any changes to the education system, through which it was achieved higher proficiency and qualifications of members of the security forces. The theoretical part of the thesis handles the most commonly used methods of educational programs, their development and sho...

  12. Improving Scheduling of Data Transmission in TDMA Systems

    Directory of Open Access Journals (Sweden)

    Timotheos Aslanidis

    2016-05-01

    Full Text Available In an era where communication has a most important role in modern societies, designing efficient algorithms for data transmission is of the outmost importance. TDMA is a technology used in many communication systems such as satellites and cell phones. In order to transmit data in such systems we need to cluster them in packages. To achieve a faster transmission we are allowed to preempt the transmission of any packet in order to resume at a later time. Such preemptions though come with a delay in order to setup for the next transmission. In this paper we propose an algorithm which yields improved transmission scheduling. This algorithm we call MGA. We have proven an approximation ratio for MGA and ran experiments to establish that it works even better in practice. In order to conclude that MGA will be a very helpful tool in constructing an improved schedule for packet routing using preemtion with a setup cost, we compare its results to two other efficient algorithms designed by researchers in the past.

  13. Advanced coding techniques for few mode transmission systems.

    Science.gov (United States)

    Okonkwo, Chigo; van Uden, Roy; Chen, Haoshuo; de Waardt, Huug; Koonen, Ton

    2015-01-26

    We experimentally verify the advantage of employing advanced coding schemes such as space-time coding and 4 dimensional modulation formats to enhance the transmission performance of a 3-mode transmission system. The performance gain of space-time block codes for extending the optical signal-to-noise ratio tolerance in multiple-input multiple-output optical coherent spatial division multiplexing transmission systems with respect to single-mode transmission performance are evaluated. By exploiting the spatial diversity that few-mode-fibers offer, with respect to single mode fiber back-to-back performance, significant OSNR gains of 3.2, 4.1, 4.9, and 6.8 dB at the hard-decision forward error correcting limit are demonstrated for DP-QPSK 8, 16 and 32 QAM, respectively. Furthermore, by employing 4D constellations, 6 × 28Gbaud 128 set partitioned quadrature amplitude modulation is shown to outperform conventional 8 QAM transmission performance, whilst carrying an additional 0.5 bit/symbol.

  14. A development of ITV system for power transmission line monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Hong Keun; Kim, Seok Ku; Lee, Kwang Joong; Lee, Won Bin [Korea Electric Power Corp. (KEPCO), Taejon (Korea, Republic of). Research Center

    1995-12-31

    Transmission lines which are important to supply the electricity installed on the terrestrially severe site such as mountains needed to be monitored to prevent electric fault by snow accelerating, icing, tree contact, fire etc. Inspections by human patrol has been done but it seems not so efficient and satisfiable. To cope with this a transmission line monitoring system using industrial television and OPGW was developed and field trilled at the site. This paper describes about the optical video transceiver, video distributor and control devices (author).

  15. Renegotiated CBR transmission in interactive video-on-demand system

    OpenAIRE

    Kamiyama, Noriaki; Li, Victor OK

    1997-01-01

    An Interactive Video-On-Demand (IVOD) system requires transmission bandwidth allocation for each user. Since the volume of data in each video frame is variable, dynamic bandwidth allocation is desirable. In this paper, a new scheme that dynamically determines required bandwidth based on the queue length at the viewers Set-Top Box (STB) is proposed. This method requires no pre-calculation, so it is easily applied to IVOD. The variance of the video transmission rate for each user is an importan...

  16. Selective transmission and channel estimation in massive MIMO systems

    Institute of Scientific and Technical Information of China (English)

    杨睿哲

    2016-01-01

    Massive MIMO systems have got extraordinary spectral efficiency using a large number of base station antennas, but it is in the challenge of pilot contamination using the aligned pilots.To address this issue, a selective transmission is proposed using time-shifted pilots with cell grouping, where the strong interfering users in downlink transmission cells are temporally stopped during the pilots transmission in uplink cells.Based on the spatial characteristics of physical channel models, the strong interfering users are selected to minimize the inter-cell interference and the cell grouping is designed to have less temporally stopped users within a smaller area.Furthermore, a Kalman estima-tor is proposed to reduce the unexpected effect of residual interferences in channel estimation, which exploits both the spatial-time correlation of channels and the share of the interference information. The numerical results show that our scheme significantly improves the channel estimation accuracy and the data rates.

  17. Fast isolation of faults in transmission systems using current transients

    Energy Technology Data Exchange (ETDEWEB)

    Perera, N.; Rajapakse, A.D. [University of Manitoba, Department of Electrical and Computer Engineering, Engineering Building, 15 Gillson Street, Winnipeg, Manitoba (Canada)

    2008-09-15

    This paper presents a protection scheme that is capable of very fast isolation of faults in high voltage transmission systems. Proposed scheme comprises set of relays connected through a telecommunication network, located at different nodes of the system. Relays use wavelet coefficients of current signals to identify the fault directions relative to their location. Fault directions identified at different locations in the system can be combined to determine the faulted line (or busbar) and isolate it. A robust single ended traveling wave based fault distance estimation approach is proposed as a backup in case of communication failure. Investigations were carried out using time domain simulations in PSCAD/EMTDC for a high voltage transmission system. (author)

  18. Information Network Systems and Information Sharing on Administrative Websites

    Institute of Scientific and Technical Information of China (English)

    HIROTA Denjiro

    2004-01-01

    In Japanese "e-government" policy, called "e-Japan", the "administrative document management system" is functioning as information searching systems. On the other hand, this system has also generated the problem that it is not fully functioning as a means for the information sharing in a governmental agency. So, the purpose of this research is to find how the administrative document management system can function as information sharing in administrative organization. For this purpose,this paper considers the current status and some problems firstly. And secondary, this paper proposes the idea and constructs some information systems using administrative official Website. This is the method and approach of this research. As a conclusion, this proposal information system functions as information sharing support systems.

  19. Model documentation: Natural gas transmission and distribution model of the National Energy Modeling System. Volume 1

    International Nuclear Information System (INIS)

    The Natural Gas Transmission and Distribution Model (NGTDM) is the component of the National Energy Modeling System (NEMS) that is used to represent the domestic natural gas transmission and distribution system. NEMS was developed in the Office of integrated Analysis and Forecasting of the Energy information Administration (EIA). NEMS is the third in a series of computer-based, midterm energy modeling systems used since 1974 by the EIA and its predecessor, the Federal Energy Administration, to analyze domestic energy-economy markets and develop projections. The NGTDM is the model within the NEMS that represents the transmission, distribution, and pricing of natural gas. The model also includes representations of the end-use demand for natural gas, the production of domestic natural gas, and the availability of natural gas traded on the international market based on information received from other NEMS models. The NGTDM determines the flow of natural gas in an aggregate, domestic pipeline network, connecting domestic and foreign supply regions with 12 demand regions. The methodology employed allows the analysis of impacts of regional capacity constraints in the interstate natural gas pipeline network and the identification of pipeline capacity expansion requirements. There is an explicit representation of core and noncore markets for natural gas transmission and distribution services, and the key components of pipeline tariffs are represented in a pricing algorithm. Natural gas pricing and flow patterns are derived by obtaining a market equilibrium across the three main elements of the natural gas market: the supply element, the demand element, and the transmission and distribution network that links them. The NGTDM consists of four modules: the Annual Flow Module, the Capacity F-expansion Module, the Pipeline Tariff Module, and the Distributor Tariff Module. A model abstract is provided in Appendix A

  20. Model documentation: Natural gas transmission and distribution model of the National Energy Modeling System. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-02-17

    The Natural Gas Transmission and Distribution Model (NGTDM) is the component of the National Energy Modeling System (NEMS) that is used to represent the domestic natural gas transmission and distribution system. NEMS was developed in the Office of integrated Analysis and Forecasting of the Energy information Administration (EIA). NEMS is the third in a series of computer-based, midterm energy modeling systems used since 1974 by the EIA and its predecessor, the Federal Energy Administration, to analyze domestic energy-economy markets and develop projections. The NGTDM is the model within the NEMS that represents the transmission, distribution, and pricing of natural gas. The model also includes representations of the end-use demand for natural gas, the production of domestic natural gas, and the availability of natural gas traded on the international market based on information received from other NEMS models. The NGTDM determines the flow of natural gas in an aggregate, domestic pipeline network, connecting domestic and foreign supply regions with 12 demand regions. The methodology employed allows the analysis of impacts of regional capacity constraints in the interstate natural gas pipeline network and the identification of pipeline capacity expansion requirements. There is an explicit representation of core and noncore markets for natural gas transmission and distribution services, and the key components of pipeline tariffs are represented in a pricing algorithm. Natural gas pricing and flow patterns are derived by obtaining a market equilibrium across the three main elements of the natural gas market: the supply element, the demand element, and the transmission and distribution network that links them. The NGTDM consists of four modules: the Annual Flow Module, the Capacity F-expansion Module, the Pipeline Tariff Module, and the Distributor Tariff Module. A model abstract is provided in Appendix A.

  1. Artificial Intelligence SVC Based Control of Two Machine Transmission System

    OpenAIRE

    Reza Bayat; Hamed ahmadi

    2013-01-01

    The main target in this paper is to present, design fuzzy logic controller (FLC) applied to static var compensator (SVC) on two machine transmission system to improve transient stability and rapid damping oscillations of synchronous generators, when power generators sudden changes occur.stability that also played important role in power systems. static var compensator with fuzzy logic controller (SVCFLC) is a new control strategy can help improve transient stability.The effect of three phase...

  2. Administration

    DEFF Research Database (Denmark)

    Bogen handler om den praksis, vi kalder administration. Vi er i den offentlige sektor i Danmark hos kontorfolkene med deres sagsmapper, computere, telefoner,, lovsamlinger,, retningslinier og regneark. I bogen udfoldes en mangfoldighed af konkrete historier om det administrative arbejde fra...... forskellige områder i den offentlige sektor. Hensigten er at forstå den praksis og faglighed der knytter sig til det administrative arbejde...

  3. NASA Administrative Data Base Management Systems, 1984

    Science.gov (United States)

    Radosevich, J. D. (Editor)

    1984-01-01

    Strategies for converting to a data base management system (DBMS) and the implementation of the software packages necessary are discussed. Experiences with DBMS at various NASA centers are related including Langley's ADABAS/NATURAL and the NEMS subsystem of the NASA metrology informaton system. The value of the integrated workstation with a personal computer is explored.

  4. Prospects of long-distance HTS DC power transmission systems

    Science.gov (United States)

    Romashov, M. A.; Sytnikov, V. E.; Shakarian, Y. G.; Ivanov, Y. V.

    2014-05-01

    Continual improvement of technologies for the safe use of power resources is a key to sustainable development of a human society. In particular, high-temperature superconductivity (HTS) should be used to meet the growing needs of the electric-power industry. It is known that HTS power cables allow us to increase the level of transmitted energy to several GW at voltage of 66-110 kV. HTS power cables of a coaxial design are almost ideal non-polluting system shielding electromagnetic field. In the present work we have tried to analyze various configurations of HTS power transmission systems, estimate the cable transmission capacitance depending on distance, and characterize reliability and efficiency of the systems.

  5. Natural gas transmission and distribution model of the National Energy Modeling System

    International Nuclear Information System (INIS)

    The Natural Gas Transmission and Distribution Model (NGTDM) is the component of the National Energy Modeling System (NEMS) that is used to represent the domestic natural gas transmission and distribution system. NEMS was developed in the Office of Integrated Analysis and Forecasting of the Energy Information Administration (EIA). NEMS is the third in a series of computer-based, midterm energy modeling systems used since 1974 by the EIA and its predecessor, the Federal Energy Administration, to analyze domestic energy-economy markets and develop projections. From 1982 through 1993, the Intermediate Future Forecasting System (IFFS) was used by the EIA for its analyses, and the Gas Analysis Modeling System (GAMS) was used within IFFS to represent natural gas markets. Prior to 1982, the Midterm Energy Forecasting System (MEFS), also referred to as the Project Independence Evaluation System (PIES), was employed. NEMS was developed to enhance and update EIA's modeling capability by internally incorporating models of energy markets that had previously been analyzed off-line. In addition, greater structural detail in NEMS permits the analysis of a broader range of energy issues. The time horizon of NEMS is the midterm period (i.e., through 2015). In order to represent the regional differences in energy markets, the component models of NEMS function at regional levels appropriate for the markets represented, with subsequent aggregation/disaggregation to the Census Division level for reporting purposes

  6. Natural gas transmission and distribution model of the National Energy Modeling System

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-02-01

    The Natural Gas Transmission and Distribution Model (NGTDM) is the component of the National Energy Modeling System (NEMS) that is used to represent the domestic natural gas transmission and distribution system. NEMS was developed in the Office of Integrated Analysis and Forecasting of the Energy Information Administration (EIA). NEMS is the third in a series of computer-based, midterm energy modeling systems used since 1974 by the EIA and its predecessor, the Federal Energy Administration, to analyze domestic energy-economy markets and develop projections. From 1982 through 1993, the Intermediate Future Forecasting System (IFFS) was used by the EIA for its analyses, and the Gas Analysis Modeling System (GAMS) was used within IFFS to represent natural gas markets. Prior to 1982, the Midterm Energy Forecasting System (MEFS), also referred to as the Project Independence Evaluation System (PIES), was employed. NEMS was developed to enhance and update EIA`s modeling capability by internally incorporating models of energy markets that had previously been analyzed off-line. In addition, greater structural detail in NEMS permits the analysis of a broader range of energy issues. The time horizon of NEMS is the midterm period (i.e., through 2015). In order to represent the regional differences in energy markets, the component models of NEMS function at regional levels appropriate for the markets represented, with subsequent aggregation/disaggregation to the Census Division level for reporting purposes.

  7. R and D of seismic emergency information transmission system

    International Nuclear Information System (INIS)

    The R and D Seismic Emergency Information Transmission System has been conducted involving the latest progress in earthquake engineering with regard to estimation techniques on the hypocenter, fault and earthquake motion parameters and in information technologies. This system is the disaster management system which consists of user site and disaster information center and is capable of mutual information transmission through Inter-Net and walkie-talkie. The concept of the disaster management system which is adaptable with DiMSIS (Disaster Management Spatial Information System) developed by professor Kameda et al. of Kyoto University has been established. Based on this concept, a prototype system has been developed. This system has following functions, (1) compatible application both in usual condition and emergency time, (2) the decentralized independence, and (3) the integration of space and time information. The system can estimate the earthquake motion information with 500 m square mesh in a local area and transmit in a few minutes. In the development of the system, seismometer network, surface soil database and amplification functions were prepared for the examination of system function. Demonstration against the Tokai area was carried out and the function was verified. (author)

  8. ICT enabled land administration systems for sustainable development

    DEFF Research Database (Denmark)

    Enemark, Stig

    2006-01-01

    This paper analyses the current Land Administration System (LAS) in Denmark with a focus on institutional arrangements, land policies, land information infrastructure, and the four land administration functions: land tenure, land value, land-use, and land development. The analysis, this way, builds...

  9. Ivermectin Mass Drug Administration to Humans Disrupts Malaria Parasite Transmission in Senegalese Villages

    OpenAIRE

    Kobylinski, Kevin C.; Sylla, Massamba; Chapman, Phillip L; Sarr, Moussa D; Foy, Brian D

    2011-01-01

    Ivermectin mass drug administration (MDA) to humans is used to control onchocerciasis and lymphatic filariasis. Recent field studies have shown an added killing effect of ivermectin MDA against malaria vectors. We report that ivermectin MDA reduced the proportion of Plasmodium falciparum infectious Anopheles gambiae sensu stricto (s.s.) in treated villages in southeastern Senegal. Ivermectin MDA is a different delivery method and has a different mode of action from current malaria control age...

  10. The transmission link of CAPS navigation and communication system

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    The Chinese Area Positioning System (CAPS) is based on communication satellites with integrated capability, which is different from the Global Positioning System (GPS), the International Maritime Satellite Organization (Inmarsat) and so on. CAPS works at C-band, and its navigation information is not directly generated from the satellite, but from the master control station on the ground and transmitted to users via the satellite. The slightly inclined geostationary-satellite orbit (SIGSO) satellites are adopted in CAPS. All of these increase the difficulty in the design of the system and terminals. In this paper, the authors study the CAPS configuration parameters of the navigation master control station, information transmission capability, and the selection of the antenna aperture of the communication center station, as well as the impact of satellite parameters on the whole communication system from the perspective of the transmission link budget. The conclusion of availability of the CAPS navigation system is achieved. The results show that the CAPS inbound communication system forms a new low-data-rate satellite communication system, which can accommodate mass communication terminals with the transmission rate of no more than 1 kbps for every terminal. The communication center station should be configured with a large-aperture antenna (about 10-15 m); spread spectrum com- munication technology should be used with the spreading gain as high as about 40 dB; reduction of the satellite transponder gain attenuation is beneficial to improving the signal-to-noise ratio of the system, with the attenuation value of 0 or 2 dB as the best choice. The fact that the CAPS navigation system has been checked and accepted by the experts and the operation is stable till now clarifies the rationality of the analysis results. The fact that a variety of experiments and applications of the satellite communication system designed according to the findings in this paper have been

  11. Federal Emergency Management Information System (FEMIS) System Administration Guide for FEMIS Version 1.5

    Energy Technology Data Exchange (ETDEWEB)

    Bower, John C.(BATTELLE (PACIFIC NW LAB)); Burnett, Robert A.(BATTELLE (PACIFIC NW LAB)); Carter, Richard J.(BATTELLE (PACIFIC NW LAB)); Downing, Timothy R.(BATTELLE (PACIFIC NW LAB)); Homer, Brian J.(BATTELLE (PACIFIC NW LAB)); Holter, Nancy A.(BATTELLE (PACIFIC NW LAB)); Johnson, Daniel M.(BATTELLE (PACIFIC NW LAB)); Johnson, Ranata L.(BATTELLE (PACIFIC NW LAB)); Johnson, Sharon M.(BATTELLE (PACIFIC NW LAB)); Loveall, Robert M.(BATTELLE (PACIFIC NW LAB)); Ramos Jr., Juan (BATTELLE (PACIFIC NW LAB)); Schulze, Stacy A.(BATTELLE (PACIFIC NW LAB)); Sivaraman, Chitra (BATTELLE (PACIFIC NW LAB)); Stephan, Alex J.(BATTELLE (PACIFIC NW LAB)); Stoops, Lamar R.(BATTELLE (PACIFIC NW LAB)); Wood, Blanche M.(BATTELLE (PACIFIC NW LAB))

    2001-12-01

    The Federal Emergency Management System (FEMIS) is an emergency management planning and response tool. The FEMIS System Administration Guide provides information on FEMIS System Administrator activities as well as the utilities that are included with FEMIS.

  12. Adaptive Image Transmission Scheme over Wavelet-Based OFDM System

    Institute of Scientific and Technical Information of China (English)

    GAOXinying; YUANDongfeng; ZHANGHaixia

    2005-01-01

    In this paper an adaptive image transmission scheme is proposed over Wavelet-based OFDM (WOFDM) system with Unequal error protection (UEP) by the design of non-uniform signal constellation in MLC. Two different data division schemes: byte-based and bitbased, are analyzed and compared. Different bits are protected unequally according to their different contribution to the image quality in bit-based data division scheme, which causes UEP combined with this scheme more powerful than that with byte-based scheme. Simulation results demonstrate that image transmission by UEP with bit-based data division scheme presents much higher PSNR values and surprisingly better image quality. Furthermore, by considering the tradeoff of complexity and BER performance, Haar wavelet with the shortest compactly supported filter length is the most suitable one among orthogonal Daubechies wavelet series in our proposed system.

  13. A Multiple-Antenna System for ISM-Band Transmission

    Directory of Open Access Journals (Sweden)

    Rinas J

    2004-01-01

    Full Text Available We present a multiple antenna system for industrial, scientific, and medical (ISM-band transmission (MASI. The hardware demonstrator was developed and realized at our institute. It enables multiple-input multiple-output (MIMO-communication applications and is capable of transmiting arbitrary signals using transmit and receive antennas in parallel. It operates in the 2.4 GHz ISM-band. The hardware concept is introduced and some design specifications are discussed. Using this transmission system, we present some measurement results to show the feasibility of MIMO concepts currently under discussion. The applications include transmit and receive diversity for single carrier and OFDM as well as blind source separation (BSS techniques.

  14. Data Acquisition and Transmission System for Building Energy Consumption Monitoring

    Directory of Open Access Journals (Sweden)

    Liang Zhao

    2013-01-01

    Full Text Available Building energy consumption monitoring and management system have been developed widely in China in order to gain the real-time data of energy consumption in buildings for analyzing it in the next state work. This paper describes a low-cost and small-sized collector based on the STM32 microcontroller, which can be placed in a building easily to implement the work of data acquisition, storage, and transmission. The collector gathers the electricity, water, heat, and energy consumption data through the RS485 field bus and stores the data into an SD card with mass storage, finally, using Internet to finish the communication and transmission to data server through TCP protocol. The collector has been used in application for two years, and the results show that the system is reliable and stable.

  15. Rigorous theoretical derivation of lumped models to transmission line systems

    Institute of Scientific and Technical Information of China (English)

    Zhao Jixiang

    2012-01-01

    By virtue of the negative electric parameter concept,i.e.negative lumped resistance,inductance,conductance and capacitance (N-RLGC),the lumped equivalent models of transmission line systems,including the circuit model,two-port π-network and T-network,are given.We start from the N-segment-ladder-like equivalent networks composed distributed parameters,and achieve the input impedance in the form of a continued fraction.Utilizing the continued fraction theory,the expressions of input impedance are obtained under three kinds of extreme cases,i.e.the load impedances are equal to zero,infinity and characteristic impedance,respectively.When the number of segment N is limited to infinity,they are transformed to lumped elements.Comparison between the distributed model and lumped model of transmission lines,the expression of tanh yd,which is the key term in the transmission line equations,are obtained by RLGC,furthermore,according to input admittance,admittance matrix and ABCD matrix of transmission lines,the lumped equivalent circuit models,π-networks and T-networks have been given.The models are verified in the frequency and time domain,respectively,showing that the models are accurate and efficient.

  16. Control strategies for VSC-based HVDC transmission system

    DEFF Research Database (Denmark)

    Stan, Ana-Irina; Stroe, Daniel Ioan; Silva, Rodrigo Da

    2011-01-01

    Throughout this paper the modeling and control of the VSC-based HVDC systems are investigated and described. Two different control methods capable of controlling such systems are proposed. Both developed control strategies are implemented in the dq synchronous reference frame. In order to analyze...... the behavior of the developed VSC-based HVDC transmission system two study cases are carried out using MATLAB/Simulink. The results obtained from simulations show acceptable performances, of the proposed strategies, when changes in the reference parameters are considered. The active power flow between...... the converters is succesfully achieved while, the independent control of active and reactive power is also verified....

  17. TRANSMISSION OF DATA USING POWER LINE CARRIER COMMUNICATION SYSTEM

    Directory of Open Access Journals (Sweden)

    Jovita Serrao

    2012-11-01

    Full Text Available This paper serves as a general and technical reference to transmission of data using a power line carrier communication system which is a preferred choice over Wireless or other Home Networking technologies due to the ease of installation, availability of AC outlets, higher throughput, low cost, reliability and security. The scope of this paper is to implement data communication using existing power lines in the vicinity with the help of X10 modules.

  18. Data Acquisition and Transmission System for Building Energy Consumption Monitoring

    OpenAIRE

    Liang Zhao; Jili Zhang; Ruobing Liang

    2013-01-01

    Building energy consumption monitoring and management system have been developed widely in China in order to gain the real-time data of energy consumption in buildings for analyzing it in the next state work. This paper describes a low-cost and small-sized collector based on the STM32 microcontroller, which can be placed in a building easily to implement the work of data acquisition, storage, and transmission. The collector gathers the electricity, water, heat, and energy consumption data thr...

  19. A GIS-based Power Transmission Management Information System

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    <正>Based on analyzing the shortcomings of electric power enterprise in traditional operation pattern,this paper combines components GIS with the application of management information system,and uses the structure which unifies three layers C/S and B/S.Also,proposed using the GPS intellectualization patrol.This may be useful to guarantees the transmission line’s operation to be safe and stable.

  20. Artificial Intelligence SVC Based Control of Two Machine Transmission System

    Directory of Open Access Journals (Sweden)

    Reza Bayat

    2013-07-01

    Full Text Available The main target in this paper is to present, design fuzzy logic controller (FLC applied to static var compensator (SVC on two machine transmission system to improve transient stability and rapid damping oscillations of synchronous generators, when power generators sudden changes occur.stability that also played important role in power systems. static var compensator with fuzzy logic controller (SVCFLC is a new control strategy can help improve transient stability.The effect of three phase fault causes instability on power system. By and large, it is very difficult to control machine speeds ,rotor angle and voltage during three-phase fault.SVCFLC is a voltage stablizer using three static var compensator which are controlled by SVC with fuzzy logic controller(FLC.The FLC is an effective device for transient stability of two-mashine transmission system. The nonlinear model dynamic formulation problem in unstable system can be solved by using artificial intelligence theorem. Fuzzy logic theory is used to improve the system stability . simulation results of three-phase fault in power system show that SVCFLC caused to increase the stability and damp out the oscillation of machine, compared with effective of SVC in the presence of power system stabilizer(PSS.

  1. System Administration Support/SWORDS G2

    Science.gov (United States)

    Dito, Scott Joseph

    2014-01-01

    The Soldier-Warfighter Operationally Responsive Deployer for Space (SWORDS) rocket is a dedicated small satellite launcher that will minimize danger and complexity in order to allow soldiers in the field to put payloads of up to 25kg into orbit from the field. The SWORDSG2 project is the development of a model, simulation, and ultimately a working application that will control and monitor the cryogenic fluid delivery to the SWORDS rocket for testing purposes. To accomplish this, the project is using the programming language environment Gensym G2. The environment is an all-inclusive application that allows development, testing, modeling, and finally operation of the unique application through graphical and programmatic methods. In addition, observation of the current cryogenic fluid delivery system in the Kennedy Space Center Cry Lab has allowed me to gain valuable experience of fluid systems and propelant delivery that is valuable to our team when developing amd modeling our own system.The ultimate goal of having a test-ready application to show to the heads of the project, and demonstrating G2's capabilities, by late 2014 will require hard work and intense study and understanding of not only the programming aspect but also the physical phenomena we want to model, observe, and control.

  2. Discontinuous Dynamics of Electric Power System with DC Transmission: A Study on DAE System

    OpenAIRE

    Susuki, Yoshihiko; Hikihara, Takashi; Chiang, Hsiao-Dong

    2008-01-01

    Transient stability of power systems with dc transmission is an important problem for planing and operation of future power networks. A differential-algebraic equation (DAE) system is proposed for transient stability analysis of a practical ac/dc power system which includes one synchronous generator operating onto both ac and dc transmissions. When transient stability analysis is performed using the DAE system, its solutions that represent dynamics of the ac/dc power system become discontinuo...

  3. Discontinuous dynamics of electric power system with dc transmission: A study on DAE system

    OpenAIRE

    Susuki, Yoshihiko; Hikihara, Takashi; Chiang, Hsiao-Dong

    2008-01-01

    Transient stability of power systems with dc transmission is an important problem for planing and operation of future power networks. A differential-algebraic equation (DAE) system is proposed for transient stability analysis of a practical ac/dc power system which includes one synchronous generator operating onto both ac and dc transmissions. When transient stability analysis is performed using the DAE system, its solutions that represent dynamics of the ac/dc power system become discontinuo...

  4. Administrative law risks of the governmental and municipal procurement system

    Directory of Open Access Journals (Sweden)

    Dyuzhikov Sergey, A.

    2015-09-01

    Full Text Available The paper deals with the administrative law risks of the Russian system of public procurement. The authors analyze the foregoing risks in the view of the correlation of risk situations, risk actions (omission and administrative law prohibitions. The authors are considering problems of the subject and some other characteristics essential to the administrative offenses in terms of the most systemic risk in this sphere – an information risk. The materials on law practice open to general use generated in more than 25 entities of the Russian Federation were used in the paper while preparing.

  5. Control and Simulation of Continuously Variable Transmission for Electric Transmission System

    Institute of Scientific and Technical Information of China (English)

    张豫南; 葛蕴珊; 马晓军; 臧克茂

    2004-01-01

    According to the study of electric transmission, the concept of the fore and the aft power chain is presented. The control method of continuously variable transmission is established in the aft chain of electric transmission based on brushless DC motor. A fuzzy controller is designed with continuous fuzzy variables and the simulation module of the aft power chain is proved by test. The fuzzy controller controls the process of continuously variable transmission steadily and the acceleration of vehicle is quick according to simulation results. The elementary performance exhibited in the simulation is a foundation for the further study of the electric transmission track vehicle.

  6. The Application of Standardization System in Corporate Management and Administration

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    This paper briefly discusses three important components of corporate standardization system and their functions and how such a system can be used in corporate management and administration. It also offers certain solutions and suggestions to some of the existing problems in the process of implementing corporate standardization system.

  7. A multicarrier TDM transmission system for DBS-A

    Science.gov (United States)

    Campanella, S. J.

    1992-03-01

    Satellite communications service for space based broadcasting has been suggested by the National Research Council's Technical Operation's Committee for the Voice of America. The service is referred to as direct broadcast from space-audio (DBS-A). This paper presents a concept incorporating low bit rate source coding for voice and music, digital modulation, forward error correction coding and Viterbi decoding, multiple satellite beams, and multiple carrier time division multiplexed (TDM) transmission to provide a system capable of world wide coverage. The system provides the capability to narrow cast to specific geographically clustered audiences. Emphasis is on the space segment (transmitter) and earth segment (receiver) using the techniques mentioned above.

  8. A novel fiber audio transmission system for secure communication

    Institute of Scientific and Technical Information of China (English)

    SU Ke; JIA Bo

    2005-01-01

    A new,simple and efficient fiber audio transmission method for the long distance secure communication is presented, which performs signal modulation by the strain-optic effects and signal demodulation by the all-fiber interferometer. The interferometer is a truly path-matched device, which eliminates much of the undesirable noise by combining the reference and the sensing arms within the same optical fiber. The sinusoidal signals adopted in the experiment are in a frequency range of 300 HZ-3 400 HZ and of the multi-frequency, and the system shows good capabilities, robust security and maintenance of audio integrity. The device may be applicable in the field of point to point secure communication of 40 kilometer long transmission range.

  9. Power and signal transmission for mobile teleoperated systems

    International Nuclear Information System (INIS)

    Appropriate means must be furnished for supplying power and for sending controlling commands to mobile teleoperated systems. Because a sizable number of possibilities are available for such applications, methods used in designing both the power and communications systems built into mobile vehicles that serve in radiological emergencies must be carefully selected. This paper describes a number of umbilical, on-board, and wireless systems used in tranmitting power that are available for mobile teleoperator services. The pros and cons of selecting appropriate methods from a list of possible communication systems (wired, fiber optic, and radio frequency) are also examined. Moreover, hybrid systems combining wireless power transmissions with command-information signals are also possible

  10. Observed reductions in Schistosoma mansoni transmission from large-scale administration of praziquantel in Uganda: a mathematical modelling study.

    Directory of Open Access Journals (Sweden)

    Michael D French

    Full Text Available BACKGROUND: To date schistosomiasis control programmes based on chemotherapy have largely aimed at controlling morbidity in treated individuals rather than at suppressing transmission. In this study, a mathematical modelling approach was used to estimate reductions in the rate of Schistosoma mansoni reinfection following annual mass drug administration (MDA with praziquantel in Uganda over four years (2003-2006. In doing this we aim to elucidate the benefits of MDA in reducing community transmission. METHODS: Age-structured models were fitted to a longitudinal cohort followed up across successive rounds of annual treatment for four years (Baseline: 2003, TREATMENT: 2004-2006; n = 1,764. Instead of modelling contamination, infection and immunity processes separately, these functions were combined in order to estimate a composite force of infection (FOI, i.e., the rate of parasite acquisition by hosts. RESULTS: MDA achieved substantial and statistically significant reductions in the FOI following one round of treatment in areas of low baseline infection intensity, and following two rounds in areas with high and medium intensities. In all areas, the FOI remained suppressed following a third round of treatment. CONCLUSIONS/SIGNIFICANCE: This study represents one of the first attempts to monitor reductions in the FOI within a large-scale MDA schistosomiasis morbidity control programme in sub-Saharan Africa. The results indicate that the Schistosomiasis Control Initiative, as a model for other MDA programmes, is likely exerting a significant ancillary impact on reducing transmission within the community, and may provide health benefits to those who do not receive treatment. The results obtained will have implications for evaluating the cost-effectiveness of schistosomiasis control programmes and the design of monitoring and evaluation approaches in general.

  11. Adaptive transmission schemes for MISO spectrum sharing systems

    KAUST Repository

    Bouida, Zied

    2013-06-01

    We propose three adaptive transmission techniques aiming to maximize the capacity of a multiple-input-single-output (MISO) secondary system under the scenario of an underlay cognitive radio network. In the first scheme, namely the best antenna selection (BAS) scheme, the antenna maximizing the capacity of the secondary link is used for transmission. We then propose an orthogonal space time bloc code (OSTBC) transmission scheme using the Alamouti scheme with transmit antenna selection (TAS), namely the TAS/STBC scheme. The performance improvement offered by this scheme comes at the expense of an increased complexity and delay when compared to the BAS scheme. As a compromise between these schemes, we propose a hybrid scheme using BAS when only one antenna verifies the interference condition and TAS/STBC when two or more antennas are illegible for communication. We first derive closed-form expressions of the statistics of the received signal-to-interference-and-noise ratio (SINR) at the secondary receiver (SR). These results are then used to analyze the performance of the proposed techniques in terms of the average spectral efficiency, the average number of transmit antennas, and the average bit error rate (BER). This performance is then illustrated via selected numerical examples. © 2013 IEEE.

  12. Evaluating parasite densities and estimation of parameters in transmission systems

    Directory of Open Access Journals (Sweden)

    Heinzmann D.

    2008-09-01

    Full Text Available Mathematical modelling of parasite transmission systems can provide useful information about host parasite interactions and biology and parasite population dynamics. In addition good predictive models may assist in designing control programmes to reduce the burden of human and animal disease. Model building is only the first part of the process. These models then need to be confronted with data to obtain parameter estimates and the accuracy of these estimates has to be evaluated. Estimation of parasite densities is central to this. Parasite density estimates can include the proportion of hosts infected with parasites (prevalence or estimates of the parasite biomass within the host population (abundance or intensity estimates. Parasite density estimation is often complicated by highly aggregated distributions of parasites within the hosts. This causes additional challenges when calculating transmission parameters. Using Echinococcus spp. as a model organism, this manuscript gives a brief overview of the types of descriptors of parasite densities, how to estimate them and on the use of these estimates in a transmission model.

  13. The transmission link of CAPS navigation and communication system

    Institute of Scientific and Technical Information of China (English)

    CUI JunXia; SHI HuLi; CHEN JiBin; PEI Jun

    2009-01-01

    The Chinese Area Positioning System (CAPS) is based on communication satellites with integrated oapability,whioh is different from the Global Positioning System (GPS),the International Maritime Satellite Organization (Inmarsat) and so on.CAPS works at G-band,and its navigation information ie not directly generated from the satellite,but from the master control station on the ground and transmitted to users via the satellite.The slightly inclined geostationary-satellite orbit (SIGSO) satellites are adopted in CAPS.All of these increase the difficulty in the design of the system and terminals.In this paper,the authors study the CAPS oonfiguration parameters of the navigation master control station,information transmission capability,and the selection of the antenna aperture of the communication oenter station,as well as the impact of satellite parameters on the whole communication system from the perspective of the transmission link budget.The conclusion of availability of the GAPS navigation system is achieved.The results show that the GAPS inbound communication system forms a new low-data-rate satellite communicaUon system,which can accommodate mass communication termihale with the transmission rate of no more than 1 kbps for every terminal.The communication center station should be configured with a large-aperture antenna (about 10--15 m); spread spectrum communication technology should be used with the spreading gain as high as about 40 dB; reduction of the satellite transponder gain attenuation is beneficial to improving the signal-to-noise ratio of the system,with the attenuation value of 0 or 2 dB as the best choice.The fact that the GAPS navigation system has been checked and aooepted by the experts and the operation is stable till now larifies the rationality of the analysis results.The fact that a variety of experiments and applications of the satellite communication system designed according to the findings in this paper have been successfully carried out

  14. Peak Power Reduction in OFDM Systems for Multicarrier Transmission

    Directory of Open Access Journals (Sweden)

    Sabhyata Uppal

    2013-05-01

    Full Text Available The transmit signals in an OFDM system can have high peak values in the time domain since many subcarrier components are added via an IFFT operation. Therefore, OFDM systems are known to have a high PAPR (Peak-to-Average Power Ratio, compared with single-carrier systems. In fact, the high PAPR is one of the most detrimental aspects in the OFDM system, as it decreases the SQNR (Signal-to-Quantization Noise Ratio of ADC (Analog-to-Digital Converter and DAC (Digital-to-Analog Converter while degrading the efficiency of the power amplifier in the transmitter. This study describes some of the important PAPR reduction techniques for multicarrier transmission including amplitude clipping and filtering, coding and partial transmit.

  15. A flexible computerized system for environmental data acquisition and transmission

    Science.gov (United States)

    Zappalà, G.

    2009-04-01

    In recent years increasing importance has been addressed to the knowledge of the marine environment, either to help detecting and understanding global climate change phenomena, or to protect and preserve those coastal areas, where multiple interests converge (linked to the tourism, recreational or productive activities…) and which suffer greater impact from anthropogenic activities; this has in turn stimulated the start of research programs devoted to the monitoring and surveillance of these particular zones, coupling the needs for knowledge, sustainable development and exploitation of natural resources. There is an increasing need to have data available in real time or near real time in order to intervene in emergency situations. Cabled or wireless data transmission can be used. The first allows the transmission of a higher amount of data only in coastal sites, while the second gives a bigger flexibility in terms of application to different environments; more, using mobile phone services (either terrestrial or satellite), it is possible to allocate the data centre in the most convenient place, without any need of proximity to the sea. Traditional oceanographic techniques, based on ship surveys, hardly fit the needs of operational oceanography, because of their high cost and fragmentary nature, both in spatial and temporal domains. To obtain a good synopticity, it is necessary to complement traditional ship observations with measurements from fixed stations (buoys moored in sites chosen to be representative of wider areas, or to constitute a sentinel against the arrival of pollutants), satellite observations, use of ships of opportunity and of newly developed instruments, like the gliders, or towed sliding devices, like the SAVE. Modern instruments rely on an electronic heart; an integrated hardware-software system developed in Messina is here presented, used in various versions to control data acquisition and transmission on buoys or on ship

  16. A flexible computerized system for environmental data acquisition and transmission

    Science.gov (United States)

    Zappalà, G.

    2009-04-01

    In recent years increasing importance has been addressed to the knowledge of the marine environment, either to help detecting and understanding global climate change phenomena, or to protect and preserve those coastal areas, where multiple interests converge (linked to the tourism, recreational or productive activities…) and which suffer greater impact from anthropogenic activities; this has in turn stimulated the start of research programs devoted to the monitoring and surveillance of these particular zones, coupling the needs for knowledge, sustainable development and exploitation of natural resources. There is an increasing need to have data available in real time or near real time in order to intervene in emergency situations. Cabled or wireless data transmission can be used. The first allows the transmission of a higher amount of data only in coastal sites, while the second gives a bigger flexibility in terms of application to different environments; more, using mobile phone services (either terrestrial or satellite), it is possible to allocate the data centre in the most convenient place, without any need of proximity to the sea. Traditional oceanographic techniques, based on ship surveys, hardly fit the needs of operational oceanography, because of their high cost and fragmentary nature, both in spatial and temporal domains. To obtain a good synopticity, it is necessary to complement traditional ship observations with measurements from fixed stations (buoys moored in sites chosen to be representative of wider areas, or to constitute a sentinel against the arrival of pollutants), satellite observations, use of ships of opportunity and of newly developed instruments, like the gliders, or towed sliding devices, like the SAVE. Modern instruments rely on an electronic heart; an integrated hardware-software system developed in Messina is here presented, used in various versions to control data acquisition and transmission on buoys or on ship

  17. ARQ schemes for data transmission in mobile radio systems

    Science.gov (United States)

    Comroe, R. A.; Costello, D. J., Jr.

    1984-01-01

    The problem of providing data communications over a land mobile radio channel is considered, taking into account error detection combined with retransmission on request as a means of obtaining reliability in digital data transmission. The considered systems are referred to as automatic RQ (repeat-request) or ARQ. It is pointed out that the distinguishing features of a land mobile radio (LMR) system, as far as the ARQ protocol is concerned, are a frequency or pair of frequencies shared by a large population of half-duplex users which cannot transmit and receive simultaneously. A description is presented of those variations of ARQ which are adaptable to an LMR system. A new channel model for a fading LMR channel is developed, and several ARQ protocols and some new protocol combinations are described. The relationships are developed for a description of the various protocols in terms of channel failure probabilities. Undetected error probabilities are developed and compared.

  18. Generation and transmission of greenhouse gases in river system

    Institute of Scientific and Technical Information of China (English)

    ZHANG Yu; WANG Shu-bo

    2016-01-01

    The research progress on the current domestic and foreign about river water system of the greenhouse gas methane(CH4), and nitrous oxide(N2O) generation, transmission and release mechanism are reviewed in this paper. At present, at home and abroad of river water system of methane production and release of the driving factors and mechanism has been basically clear, but the N2O production mechanism is not clear, multi factor interaction of river water system of N2O production and release of complex, in different regions and time of result differences. The calculation of water flux of N2O river discharge coefficient of river IPCC released based on N2O, the release amount may underestimate the river water N2O.

  19. Comparison of scientific and administrative database management systems

    Science.gov (United States)

    Stoltzfus, J. C.

    1983-01-01

    Some characteristics found to be different for scientific and administrative data bases are identified and some of the corresponding generic requirements for data base management systems (DBMS) are discussed. The requirements discussed are especially stringent for either the scientific or administrative data bases. For some, no commercial DBMS is fully satisfactory, and the data base designer must invent a suitable approach. For others, commercial systems are available with elegant solutions, and a wrong choice would mean an expensive work-around to provide the missing features. It is concluded that selection of a DBMS must be based on the requirements for the information system. There is no unique distinction between scientific and administrative data bases or DBMS. The distinction comes from the logical structure of the data, and understanding the data and their relationships is the key to defining the requirements and selecting an appropriate DBMS for a given set of applications.

  20. Building Fit-for-Purpose Land Administration Systems

    DEFF Research Database (Denmark)

    Enemark, Stig; Bell, Keith; Lemmen, Christiaan;

    2014-01-01

    of society today and that can be incrementally improved over time. The paper addresses some of the key technological, economic, legal, and social issues related to building fit-for purpose land administration systems in support of sustainable and transparent land governance especially in developing countries......Arguably sound land governance is the key to achieve sustainable development and to support the global agenda set by adoption of the Millennium Development Goals (MDGs). The operational component of land governance is the country specific land administration systems dealing with the four key...... functions of land tenure, land value, land, and land development. Land administration systems - whether highly advanced or very basic – require a land parcel framework to operate. Building such a land parcel framework – showing the way land is divided into parcels and plots for specific use and possession...

  1. Transmission imaging for integrated PET-MR systems

    Science.gov (United States)

    Bowen, Spencer L.; Fuin, Niccolò; Levine, Michael A.; Catana, Ciprian

    2016-08-01

    Attenuation correction for PET-MR systems continues to be a challenging problem, particularly for body regions outside the head. The simultaneous acquisition of transmission scan based μ-maps and MR images on integrated PET-MR systems may significantly increase the performance of and offer validation for new MR-based μ-map algorithms. For the Biograph mMR (Siemens Healthcare), however, use of conventional transmission schemes is not practical as the patient table and relatively small diameter scanner bore significantly restrict radioactive source motion and limit source placement. We propose a method for emission-free coincidence transmission imaging on the Biograph mMR. The intended application is not for routine subject imaging, but rather to improve and validate MR-based μ-map algorithms; particularly for patient implant and scanner hardware attenuation correction. In this study we optimized source geometry and assessed the method’s performance with Monte Carlo simulations and phantom scans. We utilized a Bayesian reconstruction algorithm, which directly generates μ-map estimates from multiple bed positions, combined with a robust scatter correction method. For simulations with a pelvis phantom a single torus produced peak noise equivalent count rates (34.8 kcps) dramatically larger than a full axial length ring (11.32 kcps) and conventional rotating source configurations. Bias in reconstructed μ-maps for head and pelvis simulations was  ⩽4% for soft tissue and  ⩽11% for bone ROIs. An implementation of the single torus source was filled with 18F-fluorodeoxyglucose and the proposed method quantified for several test cases alone or in comparison with CT-derived μ-maps. A volume average of 0.095 cm‑1 was recorded for an experimental uniform cylinder phantom scan, while a bias of  images with significantly higher SNR than competing fixed geometries at matched total acquisition time.

  2. Nonlinear Vibroimpact Characteristics of a Planetary Gear Transmission System

    Directory of Open Access Journals (Sweden)

    Jianxing Zhou

    2016-01-01

    Full Text Available In order to research the vibroimpact characteristics of a planetary gear transmission system under high speed and lightly loaded conditions, a new modeling method is proposed. In the modeling process, linear spring was used to simulate gear mesh elasticity under heavy load cases, and Hertz contact theory was used to calculate the contact force of gear pair under light load cases. Then, effects of the working conditions on the system vibroimpact characteristics are analyzed. The results show that, with input speed growing, the mesh force produced obvious fluctuations on the resonance frequencies of the sun gear and carrier torsion vibration, ring gear’s transverse vibration under the heavy load. Under light load condition, the collision vibration occurs in the gear pair; the changing trend of the contact force shows strongly nonlinear characteristics. The time of mesh-apart in gears pair decreases gradually as the load is increased; until it reaches collision vibration threshold value, the gear pair is no longer mesh-apart. With increasing of the input speed, the time of mesh-apart is decreased gradually; the fluctuation amplitude of contact force shows a linearly increasing trend. The study provides useful theoretical guideline for planetary gear transmission low-noise design.

  3. Information systems security policies: a survey in Portuguese public administration

    OpenAIRE

    Lopes, Isabel Maria; Sá-Soares, Filipe de

    2010-01-01

    Information Systems Security is a relevant factor for present organizations. Among the security measures, policies assume a central role in literature. However, there is a reduced number of empirical studies about the adoption of information systems security policies. This paper contributes to mitigate this flaw by presenting the results of a survey in the adoption of Information System Security Policies in Local Public Administration in Portugal. The results are discussed in light of lite...

  4. Shift Control System of Heavy-duty Vehicle Automatic Transmission

    Directory of Open Access Journals (Sweden)

    Yan Zhang

    2013-12-01

    Full Text Available Heavy-duty vehicle hydrodynamic mechanical automatic transmission shifting operation system was designed, mathematical model of its simplified hydraulic system was established and simulation model of shifting operation system was established with AMESim, the simulation experiment was carried out, then oil pressure curves of each clutch hydraulic cylinder were obtained when giving forward gear or reverse gear signals. The simulation results show that shifting operating system meets the design requirements, and verify the correctness of the model. The shift timing is correct, and there is no power interruption or gear overlap during the shift transition process. Joint oil pressure of designed system is stable, and shifting shock is small. The research results are providing the basis for further study of shifting operation system and a reasonable platform for the studying of shift schedule and quality. The theoretical design method and dynamic simulation experiment will be feasible for the real industrial applications. The research results can be used in design and optimization of hydraulic system

  5. SURGNET: An Integrated Surgical Data Transmission System for Telesurgery

    Directory of Open Access Journals (Sweden)

    Sriram Natarajan

    2009-01-01

    Full Text Available Remote surgery information requires quick and reliable transmission between the surgeon and the patient site. However, the networks that interconnect the surgeon and patient sites are usually time varying and lossy which can cause packet loss and delay jitter. In this paper we propose SURGNET, a telesurgery system for which we developed the architecture, algorithms and implemented it on a testbed. The algorithms include adaptive packet prediction and buffer time adjustment techniques which reduce the negative effects caused by the lossy and time varying networks. To evaluate the proposed SURGNET system, at the therapist site, we implemented a therapist panel which controls the force feedback device movements and provides image analysis functionality. At the patient site we controlled a virtual reality applet built in Matlab. The varying network conditions were emulated using NISTNet emulator. Our results show that even for severe packet loss and variable delay jitter, the proposed integrated synchronization techniques significantly improve SURGNET performance.

  6. Dynamic security risk assessment and optimization of power transmission system

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    The paper presents a practical dynamic security region (PDSR) based dynamic security risk assessment and optimization model for power transmission system. The cost of comprehensive security control and the influence of uncertainties of power injections are considered in the model of dynamic security risk assessment. The transient stability constraints and uncertainties of power injections can be considered easily by PDSR in form of hyper-box. A method to define and classify contingency set is presented, and a risk control optimization model is given which takes total dynamic insecurity risk as the objective function for a dominant con-tingency set. An optimal solution of dynamic insecurity risk is obtained by opti-mizing preventive and emergency control cost and contingency set decomposition. The effectiveness of this model has been proved by test results on the New Eng-land 10-genarator 39-bus system.

  7. Post-Mass Drug Administration Transmission Assessment Survey for Elimination of Lymphatic Filariasis in La Ciénaga, Dominican Republic.

    Science.gov (United States)

    Noland, Gregory S; Blount, Stephen; Gonzalez, Manuel

    2015-12-01

    The Dominican Republic is one of four remaining countries in the Americas with lymphatic filariasis (LF). Annual mass drug administration (MDA) with albendazole and diethylcarbamazine was conducted in La Ciénaga, an impoverished urban barrio in Santo Domingo, from 2004 to 2006. Eight years after the last MDA, a transmission assessment survey (TAS) was conducted in November-December 2014 to determine if LF transmission remains absent. Of 815 first and second grade primary school students (mean age: 6.51 years; range 5-9) tested by immunochromatographic test (ICT), zero (0.0%) were positive. This is below the TAS critical cutoff of nine, indicating that the area "passed" TAS and that transmission remains interrupted in La Ciénaga. Importantly, this also provides evidence that three rounds of effective (> 65% coverage) MDA, likely aided by environmental improvements and periodic school-based albendazole monotherapy MDA, achieved interruption of LF transmission from a relatively low-transmission setting.

  8. Decline in lymphatic filariasis transmission with annual mass drug administration using DEC with and without albendazole over a 10year period in India.

    Science.gov (United States)

    Sunish, I P; Kalimuthu, M; Rajendran, R; Munirathinam, A; Ashok Kumar, V; Nagaraj, J; Tyagi, B K

    2015-02-01

    The National Programme for the Elimination of Lymphatic Filariasis is underway in the endemic districts of Tamil Nadu State, South India, since 2001. Annual mass drug administration (MDA) was carried out by the state health department to all eligible individuals. The impact of MDAs on transmission parameters was evaluated in 2 revenue blocks, viz, one with DEC alone and the other with a combination of albendazole. After 10 years with 6 annual MDAs, the transmission indices reached low levels in both treatment arms, but still persisted. However, the DEC alone arm showed higher transmission rates, compared to the DEC+ALB arm. Few villages which demonstrated persistent transmission need to be targeted with an additional control measure viz, vector control, to achieve LF elimination. It is evident from the 10 year period of the study that inclusion of albendazole along with DEC has significantly reduced the transmission indices to almost nil level, as compared to DEC alone.

  9. Decline in lymphatic filariasis transmission with annual mass drug administration using DEC with and without albendazole over a 10year period in India.

    Science.gov (United States)

    Sunish, I P; Kalimuthu, M; Rajendran, R; Munirathinam, A; Ashok Kumar, V; Nagaraj, J; Tyagi, B K

    2015-02-01

    The National Programme for the Elimination of Lymphatic Filariasis is underway in the endemic districts of Tamil Nadu State, South India, since 2001. Annual mass drug administration (MDA) was carried out by the state health department to all eligible individuals. The impact of MDAs on transmission parameters was evaluated in 2 revenue blocks, viz, one with DEC alone and the other with a combination of albendazole. After 10 years with 6 annual MDAs, the transmission indices reached low levels in both treatment arms, but still persisted. However, the DEC alone arm showed higher transmission rates, compared to the DEC+ALB arm. Few villages which demonstrated persistent transmission need to be targeted with an additional control measure viz, vector control, to achieve LF elimination. It is evident from the 10 year period of the study that inclusion of albendazole along with DEC has significantly reduced the transmission indices to almost nil level, as compared to DEC alone. PMID:25205435

  10. Building Fit-For-Purpose Land Administration Systems: Guiding Principles

    DEFF Research Database (Denmark)

    Enemark, Stig; McLaren, Robin; Lemmen, Christiaan

    2016-01-01

    This paper describes the key principles for building sustainable and Fit-For-Purpose (FFP) Land Administration Systems especially in developing countries where often less the 10 per cent of the land and population is included in the formal systems. New solutions are required that can deliver...... security of tenure for all, are affordable and can be quickly developed and incrementally improved over time. The Fit-For-Purpose (FFP) approach to land administration has emerged to meet these simple, but challenging requirements. It is argued that the FFP approach is the only viable solution to solving...... Administration in collaboration with key partners. This paper presents the conceptual outcome of this project. The resulting GLTN publication will be launched at the FIG Working Week, Christchurch, New Zealand, May 2016. The FFP approach has three fundamental characteristics. Firstly there is a focus...

  11. Impacts of Western Area Power Administration`s power marketing alternatives on electric utility systems

    Energy Technology Data Exchange (ETDEWEB)

    Veselka, T.D.; Portante, E.C.; Koritarov, V. [and others

    1995-03-01

    This technical memorandum estimates the effects of alternative contractual commitments that may be initiated by the Western Area Power Administration`s Salt Lake City Area Office. It also studies hydropower operational restrictions at the Salt Lake City Area Integrated Projects in combination with these alternatives. Power marketing and hydropower operational effects are estimated in support of Western`s Electric Power Marketing Environmental Impact Statement (EIS). Electricity production and capacity expansion for utility systems that will be directly affected by alternatives specified in the EIS are simulated. Cost estimates are presented by utility type and for various activities such as capacity expansion, generation, long-term firm purchases and sales, fixed operation and maintenance expenses, and spot market activities. Operational changes at hydropower facilities are also investigated.

  12. Toroidal Continuously Variable Transmission Systems: Terminology and Present Studies

    Directory of Open Access Journals (Sweden)

    Ahmet YILDIZ

    2014-04-01

    Full Text Available The use of continuously variable transmission systems in many different areas such as aerospace, robotics, machinery and automotive industries as an alternative to conventional speed changers with constant ratio becomes widely.Especially in the automotive industry, these systems have been used increasingly, since they enable that internal combustion engines in vehicles run at optimal speeds, and consequently provide considerable fuel savings and therefore lower emission values and also they provide powerful acceleration and quiet working. CVT systems have several constructive variants such as belted, chained, balled, toroidal etc. In this paper, toroidal CVT systems based on elastohydrodynamic principles are concerned with, and fundamental works of last two decades in this field are reviewed. However, the relevant terminology and dynamics along with the control of these systems are briefly treated for better understanding of the literature mentioned. Attention is drawn to the lack of some significant issues in present research works, and potential future works are pointed out. This paper, to the authors’ knowledge, will be the first review on toroidal CVT systems in Turkish literature

  13. Analysis the Performance of Coded WSK-DWDM Transmission System

    Directory of Open Access Journals (Sweden)

    Bobby Barua

    2012-12-01

    Full Text Available Dense Wavelength Division Multiplexing (DWDM is the system with more than eight active wavelengths per fiber. Again high data rates as well as long spans between amplifiers in a chain require high optical power per channel to satisfy the signal to noise ratio (SNR requirements. So the DWDM systems with long repeater-less spans, the simultaneous requirements of high launched power and low dispersion fibers lead to the generation of new waves by four-wave mixing (FWM, which degrades the performance of a multi-channel transmission system. Several methods have been proposed to mitigate the effect of FWM crosstalk. All these works are performed considering only binary WSK scheme. Although M-ary WSK (M>2 schemes have higher spectral efficiency than binary WSK system. Again, the BER performances for M-ary WDM system are not satisfactory with the effect of FWM. Therefore, in this paper we include the effect of FWM on the performance of an M-ary WDM system and try to mitigate the effect by employing the energy efficient convolution code in a normal dispersive fiber as well as in a dispersion shifted fiber (DSF.

  14. Transient dynamics in electric power system with dc transmission: Fractal growth in stability boundary

    OpenAIRE

    Susuki, Yoshihiko; Hikihara, Takashi

    2005-01-01

    The paper is concerned with transient dynamics and stability of an electric power system with DC transmission. Nowadays, DC transmission systems are widely applied to conventional electric power systems. However, the transient dynamics of AC/DC power systems, affected by the active power that flows into DC transmissions, is not entirely understood. The paper derives a non-symmetrical swing equation system to analyse the transient dynamics of an AC/DC power system. The non-symmetry implies a u...

  15. Identity Management Mismatch Challenges in the Danish Municipality Administration System

    DEFF Research Database (Denmark)

    Andersen, Mads Schaarup; Christensen, Henrik Bærbak

    2010-01-01

    Integrating a COTS product in a company’s product portfolio is appealing from a business perspective but highly challenging from the perspective of the software architecture. In this paper we outline research challenges regarding authorization in the identity management part of the Danish...... municipality administration system, called Opus BRS, a system that integrates SAP, legacy mainframe systems, and other systems present in the individual municipalities. Each of these systems defines their own access control model and architecture, which leads to architectural mismatch that impacts security...

  16. Hybrid energy harvesting/transmission system for embedded devices

    Science.gov (United States)

    Hehr, Adam; Park, Gyuhae; Farinholt, Kevin

    2012-04-01

    In most energy harvesting applications the need for a reliable long-term energy supply is essential in powering embedded sensing and control electronics. The goal of many harvesters is to extract energy from the ambient environment to power hardware; however in some applications there may be conditions in which the harvester's performance cannot meet all of the demands of the embedded electronics. One method for addressing this shortfall is to supplement harvested power through the transmission of wireless energy, a concept that has successfully been demonstrated by the authors in previous studies. In this paper we present our findings on the use of a single electromagnetic coil to harvest kinetic energy in a solenoid configuration, as well as background and directed wireless energy in the 2.4 GHz radio frequency (RF) bands commonly used in WiFi and cellular phone applications. The motivation for this study is to develop a compact energy harvester / receiver that conserves physical volume, while providing multi-modal energy harvesting capabilities. As with most hybrid systems there are performance trade-offs that must be considered when capturing energy from different physical sources. As part of this paper, many of the issues related to power transmission, physical design, and potential applications are addressed for this device.

  17. Security administration plan for HANDI 2000 business management system

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, D.

    1998-09-29

    This document encompasses and standardizes the integrated approach for security within the PP and Ps applications, It also identifies the security tools and methods to be used. The Security Administration Plan becomes effective as of this document`s acceptance and will provide guidance through implementation efforts and, as a ``living document`` will support the operations and maintenance of the system.

  18. Transmission media appropriate laser-microwave solar power satellite system

    Science.gov (United States)

    Schäfer, C. A.; Gray, D.

    2012-10-01

    As a solution to the most critical problems with Solar power Satellite (SPS) development, a system is proposed which uses laser power transmission in space to a receiver high in the atmosphere that relays the power to Earth by either cable or microwave power transmission. It has been shown in the past that such hybrid systems have the advantages of a reduction in the mass of equipment required in geostationary orbit and avoidance of radio frequency interference with other satellites and terrestrial communications systems. The advantage over a purely laser power beam SPS is that atmospheric absorption is avoided and outages due to clouds and precipitation will not occur, allowing for deployment in the equatorial zone and guaranteeing year round operation. This proposal is supported by brief literature surveys and theoretical calculations to estimate crucial parameters in this paper. In relation to this concept, we build on a recently proposed method to collect solar energy by a tethered balloon at high altitude because it enables a low-cost start for bringing the first Watt of power to Earth giving some quick return on investment, which is desperately missing in the traditional SPS concept. To tackle the significant problem of GW-class SPSs of high launch cost per kg mass brought to space, this paper introduces a concept which aims to achieve a superior power over mass ratio compared to traditional satellite designs by the use of thin-film solar cells combined with optical fibres for power delivery. To minimise the aperture sizes and cost of the transmitting and receiving components of the satellite and high altitude receiver, closed-loop laser beam pointing and target tracking is crucial for pointing a laser beam onto a target area that is of similar size to the beam's diameter. A recently developed technique based on optical phase conjugation is introduced and its applicability for maintaining power transmission between the satellite and high altitude receiver is

  19. Research on target information optics communications transmission characteristic and performance in multi-screens testing system

    Science.gov (United States)

    Li, Hanshan

    2016-04-01

    To enhance the stability and reliability of multi-screens testing system, this paper studies multi-screens target optical information transmission link properties and performance in long-distance, sets up the discrete multi-tone modulation transmission model based on geometric model of laser multi-screens testing system and visible light information communication principle; analyzes the electro-optic and photoelectric conversion function of sender and receiver in target optical information communication system; researches target information transmission performance and transfer function of the generalized visible-light communication channel; found optical information communication transmission link light intensity space distribution model and distribution function; derives the SNR model of information transmission communication system. Through the calculation and experiment analysis, the results show that the transmission error rate increases with the increment of transmission rate in a certain channel modulation depth; when selecting the appropriate transmission rate, the bit error rate reach 0.01.

  20. Artificial intelligence in the service of system administrators

    CERN Document Server

    Haen, Christophe; Bonaccorsi, E; Neufeld, N

    2012-01-01

    The LHCb online system relies on a large and heterogeneous IT infrastructure made from thousands of servers on which many different applications are running. They run a great variety of tasks: critical ones such as data taking and secondary ones like web servers. The administration of such a system and making sure it is working properly represents a very important workload for the small expert-operator team. Research has been performed to try to automatize (some) system administration tasks, starting in 2001 when IBM defined the so-called self objectives supposed to lead to autonomic computing. In this context, we present a framework that makes use of artificial intelligence and machine learning to monitor and diagnose at a low level and in a non intrusive way Linux-based systems and their interaction with software. Moreover, the multi agent approach we use, coupled with an object oriented paradigm architecture should increase our learning speed a lot and highlight relations between problems.

  1. Oral High-Dose Ankaferd Administration Effects on Gastrointestinal System

    OpenAIRE

    Akbal, Erdem; Köklü, Seyfettin; Astarcı, Hesna Müzeyyen; Koçak, Erdem; Karaca, Gökhan; Beyazıt, Yavuz; Topcu, Güler; Acar, Bilgehan; Ergün, Dilek; Haznedaroğlu, İbrahim Celalettin

    2013-01-01

    Background and aims: Ankaferd Blood Stopper (ABS) is a herbal extract obtained from five different plants. It has a therapeutic potential for the management of external hemorrhage and controlling gastrointestinal bleeding. However, ABS's effects are not unknown on gastrointestinal systems. The aim of this study was to assess the effect of short- and long-term systemic exposure and gastrointestinal safety following the oral administration of high-dose ABS in rats. Methods: Eighteen healthy adu...

  2. Redesign and modernization of radioactive waste administration systems in Ukraine

    Energy Technology Data Exchange (ETDEWEB)

    Nieder-Westermann, Gerald H.; Walther, Thorsten; Krone, Juergen [DBE Technology GmbH, Peine (Germany)

    2016-06-15

    The European Commission (EC) has undertaken a series of projects to render assistance to Ukraine in modernizing and redesigning the Ukrainian approach to the administration, management and ultimately disposal of all forms of radioactive waste, including waste associated with the Chornobyl accident as well as waste generated as part of the Ukrainian energy infrastructure and from industrial and medical applications. One of the most recently completed projects focused on modernizing Ukraine's management and administrative systems responsible for the disposal of radioactive waste.

  3. Optimal transmissions for space-time coded OFDM UWB systems

    Institute of Scientific and Technical Information of China (English)

    WANG Jun-fang; ZHU Guang-xi; JIN Jiang

    2005-01-01

    The emerging ultra-wideband (UWB) system offers a great potential for the design of high-speed short-range communications. Compared with great progress at physical layer, the corresponding medium access control (MAC) layer designs are naturally placed on the schedules. We focus on the optimal power load scheme, which is an integral part of the MAC layer protocol design, for UWB space-time coded (STC) orthogonal frequency-division multiplexing (OFDM)transmissions. Assumed the transmitter has perfect or partial channel stage information (CSI). Based on the optimization criteria of maximizing capacity, three kinds of power load schemes were presented with different tradeoff among performance, complexity and feedback bandwidth overhead. The proposed schemes are verified and compared under the channel prototype proposed by IEEE 802.15.3a Task Group.

  4. EHV/HV Underground Cable Systems for Power Transmission

    DEFF Research Database (Denmark)

    Bak, Claus Leth

    lines are undesirable. Therefore, we must come up with an alternative, acceptable to the public. Underground cables fulfil the above mentioned need to be more publically acceptable, but, for long transmission lines, they are in many ways unproven. Guidelines for their design are needed. This thesis...... presents the results of a decade of underground cable research studies performed in Denmark by Danish TSO Energinet.dk and the Department of Energy Technology. The thesis is based upon a number of selected publications and summarises the results of these at a presentation level intended to have an easier...... cables is given, and secondly, the modelling approach and validation of this is discussed. Thirdly, making up the main core of the work presented, dynamics of underground cable systems are discussed and important cases to study are highlighted, and next, protection and fault location are discussed...

  5. On multiuser switched diversity transmission for spectrum sharing systems

    KAUST Repository

    Qaraqe, Marwa

    2012-01-01

    In this paper, we develop multiuser access schemes for spectrum sharing systems whereby secondary users share the spectrum with primary users. In particular, we devise two schemes for selecting the user among those that satisfy the interference constraints and achieve an acceptable signal-to-noise ratio (SNR) level. The first scheme selects the user with the maximum SNR at the receiver, whereas in the second scheme the users are scanned in a sequential manner until an acceptable user is found. In addition, we consider two power adaptive settings. In the on/off power adaptive setting, the users transmit based on whether the interference constraint is met or not while in the full power adaptive setting, the users vary their transmission power to satisfy the interference constraint. Finally, we present numerical results of our proposed algorithms where we show the trade-off between the average spectral efficiency and average feedback load of both schemes. © 2012 ICST.

  6. Transmission imaging for integrated PET-MR systems

    Science.gov (United States)

    Bowen, Spencer L.; Fuin, Niccolò; Levine, Michael A.; Catana, Ciprian

    2016-08-01

    Attenuation correction for PET-MR systems continues to be a challenging problem, particularly for body regions outside the head. The simultaneous acquisition of transmission scan based μ-maps and MR images on integrated PET-MR systems may significantly increase the performance of and offer validation for new MR-based μ-map algorithms. For the Biograph mMR (Siemens Healthcare), however, use of conventional transmission schemes is not practical as the patient table and relatively small diameter scanner bore significantly restrict radioactive source motion and limit source placement. We propose a method for emission-free coincidence transmission imaging on the Biograph mMR. The intended application is not for routine subject imaging, but rather to improve and validate MR-based μ-map algorithms; particularly for patient implant and scanner hardware attenuation correction. In this study we optimized source geometry and assessed the method’s performance with Monte Carlo simulations and phantom scans. We utilized a Bayesian reconstruction algorithm, which directly generates μ-map estimates from multiple bed positions, combined with a robust scatter correction method. For simulations with a pelvis phantom a single torus produced peak noise equivalent count rates (34.8 kcps) dramatically larger than a full axial length ring (11.32 kcps) and conventional rotating source configurations. Bias in reconstructed μ-maps for head and pelvis simulations was  ⩽4% for soft tissue and  ⩽11% for bone ROIs. An implementation of the single torus source was filled with 18F-fluorodeoxyglucose and the proposed method quantified for several test cases alone or in comparison with CT-derived μ-maps. A volume average of 0.095 cm-1 was recorded for an experimental uniform cylinder phantom scan, while a bias of  <2% was measured for the cortical bone equivalent insert of the multi-compartment phantom. Single torus μ-maps of a hip implant phantom showed significantly less

  7. Gas data transmission system by satellite telephone; Systeme de transmission de donnees sur le gaz utilisant le telephone par satellite

    Energy Technology Data Exchange (ETDEWEB)

    Ogasawara, S.; Tanji, A. [Dengineer Co., Ltd (Japan); Akiyama, S. [Buyo Gas Company (Japan)

    2000-07-01

    Dengineer Co., Ltd. and Buyo Gas Co., Ltd. had been developing and using the data and alarm transmission system by public telephone since 1984, that was first practical use in Japan. It is very important for business management that adjusts the production value of gas by measuring gas pressures in each governor. Also, it is indispensable to know the accident of gas leakage or abnormal gas pressure quickly. But this convenient system is not spread yet in Japanese market cause of the following reasons. - Take time and cost for installation of terminal station. - Terminal station is apt to damage by thunder. - Big disaster must stop working this system. In order to solve those problems, we have developed and tested the system organized of the satellite telephone system and solar cells for power. This system will be very useful for wide place, not only Japanese market but also the area, which has no electricity and phone. Also, it will be convenient for international rescue as is able to access it from the foreign countries. (authors)

  8. Model documentation: Natural Gas Transmission and Distribution Model of the National Energy Modeling System; Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-02-24

    The Natural Gas Transmission and Distribution Model (NGTDM) is a component of the National Energy Modeling System (NEMS) used to represent the domestic natural gas transmission and distribution system. NEMS is the third in a series of computer-based, midterm energy modeling systems used since 1974 by the Energy Information Administration (EIA) and its predecessor, the Federal Energy Administration, to analyze domestic energy-economy markets and develop projections. This report documents the archived version of NGTDM that was used to produce the natural gas forecasts used in support of the Annual Energy Outlook 1994, DOE/EIA-0383(94). The purpose of this report is to provide a reference document for model analysts, users, and the public that defines the objectives of the model, describes its basic design, provides detail on the methodology employed, and describes the model inputs, outputs, and key assumptions. It is intended to fulfill the legal obligation of the EIA to provide adequate documentation in support of its models (Public Law 94-385, Section 57.b.2). This report represents Volume 1 of a two-volume set. (Volume 2 will report on model performance, detailing convergence criteria and properties, results of sensitivity testing, comparison of model outputs with the literature and/or other model results, and major unresolved issues.) Subsequent chapters of this report provide: (1) an overview of the NGTDM (Chapter 2); (2) a description of the interface between the National Energy Modeling System (NEMS) and the NGTDM (Chapter 3); (3) an overview of the solution methodology of the NGTDM (Chapter 4); (4) the solution methodology for the Annual Flow Module (Chapter 5); (5) the solution methodology for the Distributor Tariff Module (Chapter 6); (6) the solution methodology for the Capacity Expansion Module (Chapter 7); (7) the solution methodology for the Pipeline Tariff Module (Chapter 8); and (8) a description of model assumptions, inputs, and outputs (Chapter 9).

  9. Fast Decoupled Power Flow for Power System with High Voltage Direct Current Transmission Line System

    OpenAIRE

    Prechanon Kumkratug

    2010-01-01

    Problem statement: High voltage direct current transmission line system has been widely applied for control power flow in power system. The power flow analysis was the one of powerful tools by which the power system equipped was analyzed both for planning and operation strategies. Approach: This study presented the method to analyze power flow of power system consisted of HVDC system. HVDC was modeled as the complex power injections. The presented complex power injected was incorporated into ...

  10. Power System Stability Improvement of Long Transmission Line System by Using Static Var Compensator (SVC)

    OpenAIRE

    Pardeep Singh Virk

    2013-01-01

    Power system stability is defined as the ability of power system to preserve it’s steady stability or recover the initial steady state after any deviation of the system’s operation. This paper will discuss how SVC has successfully been applied to control dynamic performance of transmission system and regulate the system voltage effectively. Present time power systems are being operated nearer to their stability limits due to economic and environmental reasons. Maintaining a stable and secure ...

  11. The Diagnostic System of A – 604 Automatic Transmission

    Directory of Open Access Journals (Sweden)

    Czaban Jaroslaw

    2014-09-01

    Full Text Available Automatic gearbox gains increasing popularity in Europe. Little interest in diagnosis of such type of transmission in Poland results from the fact of small share in the whole market of operated cars, so there is a lack of availability of special diagnostic devices. These factors cause issues of expensive repairs, often involving a replacement of subassembly to new or aftermarket one. To a small extent some prophylactic diagnostic tests are conducted, which can eliminate future gearbox system failures. In the paper, the proposition of diagnostic system of popular A - 604 gearbox was presented. The authors are seeking for the possibility of using such type of devices to functional elaboration of gearboxes after renovation. The built system pursues the drive of the researched object, connected with simulated load, where special controller, replacing the original one, is responsible for controlling gearbox operation. This way is used to evaluate the mechanic and hydraulic parts' state. Analysis of signal runs, registered during measurements lets conclude about operation correctness, where as comparison with stock data verifies the technical state of an automatic gearbox.

  12. The Need of Politically Descentralization in Romanian Administrative System

    OpenAIRE

    Simona Mina

    2011-01-01

    The need for decentralization of the administrative system is one of the most discussed and acclaimed topics, in the Romanian governing acts. Decentralization, however, cannot be achieved without political decentralization, a democratization process of democracy, achieved from top to bottom, in which the state supports the evolution of the civil society through partnership, by stimulating local initiative and community development. According to Anthony Giddens’ theory, which is even more rele...

  13. Study on New Concatenated Code in WDM Optical Transmission Systems

    Institute of Scientific and Technical Information of China (English)

    YUAN Jian-guo; JIANG Ze; MAO You-ju; YE Wen-wei

    2007-01-01

    A new concatenated code of RS(255,239)+BCH(2 040,1 930) code to be suitable for WDM optical transmission systems is proposed.The simulation results show that this new concatenated code,compared with the RS(255,239)+CSOC(k0/n0=6/7,J=8) code in ITU-T G.75.1,has a lower redundancy and better error-correction performance,furthermore,its net coding gain(NCG) is respectively 0.46 dB,0.43 dB more than that of RS(255,239)+CSOC(k0/n0 =6/7,J=8) code and BCH(3 860,3 824)+BCH(2 040,1 930) code in ITU-T G.75.1 at the third iteration for the bit error rate(BER) of 10-12.Therefore,the new super forward error correction(Super-FEC) concatenated code can be better used in ultra long-haul,ultra large-capacity and ultra high-speed WDM optical communication systems.

  14. Avoidance of Pressure Oscillations in Discrete Fluid Power Systems with Transmission Lines - An Analytical Approach

    DEFF Research Database (Denmark)

    Hansen, Anders Hedegaard; Pedersen, Henrik C.

    2014-01-01

    transmission lines often impose pressure oscillation/ pressure waves to occur in systems operated discrete or very fast. The current work focus on developing an analytical algorithm computing the flow requirement into a cylinder chamber through a transmission line that will impose a smooth pressure change...... in the cylinder chamber. This is realised based on a lumped parameter transmission line model. The algorithm is tested with two different transmission line models....

  15. Absence of Frequent Herpesvirus Transmission in a Nonhuman Primate Predator-Prey System in the Wild

    OpenAIRE

    Murthy, Sripriya; Couacy-Hymann, Emmanuel; Metzger, Sonja; Nowak, Kathrin; De Nys, Helene; Boesch, Christophe; Wittig, Roman; Jarvis, Michael A.; Leendertz, Fabian; Ehlers, Bernhard

    2013-01-01

    Emergence of viruses into the human population by transmission from nonhuman primates (NHPs) represents a serious potential threat to human health that is primarily associated with the increased bushmeat trade. Transmission of RNA viruses across primate species appears to be relatively frequent. In contrast, DNA viruses appear to be largely host specific, suggesting low transmission potential. Herein, we use a primate predator-prey system to study the risk of herpesvirus transmission between ...

  16. Statistics and Analysis on Reliability of HVDC Transmission Systems of SGCC

    Institute of Scientific and Technical Information of China (English)

    Xu

    2010-01-01

    Reliability level of HVDC power transmission systems becomes an important factor impacting the entire power grid. The author analyzes the reliability of HVDC power transmission systems owned by SGCC since 2003 in respect of forced outage times, forced energy unavailability, scheduled energy unavailability and energy utilization efficiency. The results show that the reliability level of HVDC power transmission systems owned by SGCC is improving. By analyzing different reliability indices of HVDC power transmission system, the maximum asset benefits of power grid can be achieved through building a scientific and reasonable reliability evaluation system.

  17. Phronesis, a diagnosis and recovery tool for system administrators

    CERN Document Server

    Haen, Christophe; Neufeld, Niko

    The administration of a large computer infrastructure is a great challenge in many aspects and requires experts in various domains to be successful. One criterion to which the users of a data center are directly exposed is the availability of the infrastructure. A high availability comes at the cost of constant and performant monitoring solutions as well as experts ready to diagnose and solve the problems. It is unfortunately not always possible to have an expert team constantly on site. This work presents a tool which is meant to support system administrators in their tasks by diagnosing problems, offering recovery solutions, and acting as a history and knowledge database. We will first detail what large data centers are composed of and what are the various competences that are required in order to successfully administrate them. This will lead us to consider the problems that are traditionally encountered by the administrators. Those problems are at the source of this project, and we will define our goals f...

  18. Power Improvement of Transmission Line Using High Voltage Direct Current (Hvdc Transmission System

    Directory of Open Access Journals (Sweden)

    Lasisi, H

    2016-08-01

    Full Text Available The use of long EHV (Extremely High Voltage ac lines for the transmission of electrical energy increases the line reactance and susceptance which limits the thermal loadings on the line in order to keep sufficient margin against transient instability. With the scheme proposed in this paper, it is possible to load the lines very close to their limit with zero reactance and susceptance. The conductors are allowed to carry usual ac along with dc superimposed on it. The added dc power flow does not cause any transient instability. The scheme comprises a twelve-pulse bridge rectifier, dc-links, pulse width modulated (PSW-voltage sourced inverter (VSI and converter transformers. The master current controller is used to implement the scheme which senses ac current and regulates the dc current orders for converters online such that conductor current never exceeds its thermal limit. This paper gives the feasibility of converting a double circuit ac line into composite ac–dc power transmission line given the advantage of stability improvement, damping oscillations, voltage stabilization and reactive power compensation for ac weak buses. Simulation and experimental studies using MATLAB (Matrix Laboratory are carried out for the coordinated control as well as independent control of ac and dc power transmissions.

  19. Power System Stability Improvement of Long Transmission Line System by Using Static Var Compensator (SVC

    Directory of Open Access Journals (Sweden)

    Pardeep Singh Virk

    2013-09-01

    Full Text Available Power system stability is defined as the ability of power system to preserve it’s steady stability or recover the initial steady state after any deviation of the system’s operation. This paper will discuss how SVC has successfully been applied to control dynamic performance of transmission system and regulate the system voltage effectively. Present time power systems are being operated nearer to their stability limits due to economic and environmental reasons. Maintaining a stable and secure operation of a powersystem is therefore a very important and challenging issue. Shunt FACTS devices play an important role in improving the transient stability, increasing transmission capacity and damping low frequency oscillations. In this paper shunt FACTS device-SVC is used in a two area power system for improving the power system stability. MATLAB software has been used in this study.

  20. Economic Aspect of HVDC Transmission System for Indonesia Consideration in Nuclear Power Development

    International Nuclear Information System (INIS)

    As a country with hundreds million people, Indonesia needs to generate large scale power and distribute it to thorough country to improve gross domestic product of the population. In the power transmission domain, the High Voltage Direct Current (HVDC) transmission system should be considered for the next decades concerning any technical and economical problems with HVAC transmission. HVDC transmission system is the answer for the Indonesian condition. This system can connect the high energy potential regions to the high energy demand regions. HVDC is the most efficient to transport energy from one region to another one region. Dismantling and removing assets costs are included to the estimated for capital costs, while the environmental and property costs are the costs of securing designations and resource consents, and valuation and legal advice for the HVDC investment. Although converter terminals are expensive however, for long transmissions HVDC system can compensate the costs over breakeven distance through very efficient transmission system. Efficiency of HVDC is appearing from conductor wire, supporting tower, low energy loses and free space used by route of the transmission line. HVDC system is also free from some problem, concerning stability, inductive and capacitive load components, phase differences and frequency system. In the economic aspect the HVDC capital costs for the transmission options comprise estimates of the cost to design, purchase and construct new HVDC transmission components. While operating and maintenance costs of HVDC assets comprise the costs for replacement the old existing overhead transmission lines, underground and submarine cables, and HVDC converter station components. (author)

  1. Artificial Intelligence in the service of system administrators

    CERN Document Server

    CERN. Geneva

    2012-01-01

    Research has been performed to try to automatize (some) system administration tasks, starting in 2001 when IBM defined the so-called “self objectives” supposed to lead to “autonomic computing”. In this context, we present a framework that makes use of artificial intelligence and machine learning to monitor and diagnose at a low level and in a non intrusive way  Linux-based systems and their interaction with software. Moreover, the multi agent approach we use, coupled with a "object oriented paradigm" architecture should increase a lot our learning speed, and highlight relations between probl...

  2. Modelling of Hazards Effect on Safety Integrity of Open Transmission Systems

    OpenAIRE

    Karol Rástočný; Mária Franeková; Peter Holečko; Iveta Zolotová

    2016-01-01

    The paper is concerned with safety appraisal of safety-related communication systems (SRComSs) with open transmission system, where except in addition to message transmission integrity also confidentiality is recommended to be provided. The authors focused on safety analysis of safety-related messages transmission secured using cryptographic and safety code mechanisms and on the possibilities of modelling safety-related industrial communication system, where a high safety integrity level SIL3...

  3. Model documentation Natural Gas Transmission and Distribution Model of the National Energy Modeling System. Volume 1

    International Nuclear Information System (INIS)

    The Natural Gas Transmission and Distribution Model (NGTDM) of the National Energy Modeling System is developed and maintained by the Energy Information Administration (EIA), Office of Integrated Analysis and Forecasting. This report documents the archived version of the NGTDM that was used to produce the natural gas forecasts presented in the Annual Energy Outlook 1996, (DOE/EIA-0383(96)). The purpose of this report is to provide a reference document for model analysts, users, and the public that defines the objectives of the model, describes its basic approach, and provides detail on the methodology employed. Previously this report represented Volume I of a two-volume set. Volume II reported on model performance, detailing convergence criteria and properties, results of sensitivity testing, comparison of model outputs with the literature and/or other model results, and major unresolved issues

  4. Model documentation Natural Gas Transmission and Distribution Model of the National Energy Modeling System. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-02-26

    The Natural Gas Transmission and Distribution Model (NGTDM) of the National Energy Modeling System is developed and maintained by the Energy Information Administration (EIA), Office of Integrated Analysis and Forecasting. This report documents the archived version of the NGTDM that was used to produce the natural gas forecasts presented in the Annual Energy Outlook 1996, (DOE/EIA-0383(96)). The purpose of this report is to provide a reference document for model analysts, users, and the public that defines the objectives of the model, describes its basic approach, and provides detail on the methodology employed. Previously this report represented Volume I of a two-volume set. Volume II reported on model performance, detailing convergence criteria and properties, results of sensitivity testing, comparison of model outputs with the literature and/or other model results, and major unresolved issues.

  5. Design of a data transmission system based on gigabit ethernet

    Science.gov (United States)

    Yuan, Yongxin; Zhang, Lijun; Xu, Bin; Wang, Jiqiang; Yuan, Yonggang

    2013-09-01

    FPGA(Field-programmable gate array) is programmable device, characterized by high speed and reconfiguration. We could test the circuit programmed by HDL (Hardware Description Language). By observing results of simulations through ModelSim, developers could fix logic errors. Also, they could analyze performance of circuits by the results. In the system, we build the Gigabit Ethernet development platform based on a FPGA. This paper presents the technique of FPGA and Gigabit Ethernet, as well as relevant techniques. On the basis of merits and drawbacks of different design proposals and real demands, we take the EP3C10E144C8N chip belonging to the series of Cyclone III produced by Altera corp. as main controller chip. By the use of an AX88180 MAC chip produced by ASIX Electronics Corporation and a RTL8211E physical chip by Realtek Semiconductor Corporation, we build the development platform. At the receiving end, we capture data frames from the network adapter by winpcap programming and throw video data in the buffer. Considering large amounts of data in the real-time transportation, we design fixed-length queue as the primary structures for buffer. Size of a buffer unit is 32KB, which means that 32 packets can fill the buffer. When the buffer is full, we put the buffer unit to the end of the queue. We get data from buffer and hand it over to application process to display and store video data. When packet loss is detected by the system, log file will record it and thus we can check how many packets lose. The simulations by Quartus II and practical application proves that the system is stable, featuring high speed and low cost. It can be used in various high speed real-time transmission with little modification.

  6. Polar On-Line Acquisition Relay and Transmission System (POLARATS)

    Energy Technology Data Exchange (ETDEWEB)

    Yuracko, K.

    2004-07-15

    POLARATS (Polar On-Line Acquisition Relay And Transmission System) is being developed by YAHSGS LLC (YAHSGS) and Oak Ridge National Laboratory (ORNL) to provide remote, unattended monitoring of environmental parameters under harsh environmental conditions. In particular, instrumental design and engineering is oriented towards protection of human health in the Arctic, and with the additional goal of advancing Arctic education and research. POLARATS will obtain and transmit environmental data from hardened monitoring devices deployed in locations important to understanding atmospheric and aquatic pollutant migration as it is biomagnified in Arctic food chains. An Internet- and personal computer (PC)-based educational module will provide real time sensor data, on-line educational content, and will be integrated with workbooks and textbooks for use in middle and high school science programs. The educational elements of POLARATS include an Internet-based educational module that will instruct students in the use of the data and how those data fit into changing Arctic environments and food chains. POLARATS will: (1) Enable students, members of the community, and scientific researchers to monitor local environmental conditions in real time over the Internet; and (2) Provide additional educational benefits through integration with middle- and high-school science curricula. Information will be relayed from POLARATS devices to classrooms and libraries along with custom-designed POLARATS teaching materials that will be integrated into existing curricula to enhance the educational benefits realized from the information obtained.

  7. Stress transmission through a model system of cohesionless elastic grains

    Science.gov (United States)

    Da Silva, Miguel; Rajchenbach, Jean

    2000-08-01

    Understanding the mechanical properties of granular materials is important for applications in civil and chemical engineering, geophysical sciences and the food industry, as well as for the control or prevention of avalanches and landslides. Unlike continuous media, granular materials lack cohesion, and cannot resist tensile stresses. Current descriptions of the mechanical properties of collections of cohesionless grains have relied either on elasto-plastic models classically used in civil engineering, or on a recent model involving hyperbolic equations. The former models suggest that collections of elastic grains submitted to a compressive load will behave elastically. Here we present the results of an experiment on a two-dimensional model system-made of discrete square cells submitted to a point load-in which the region in which the stress is confined is photoelastically visualized as a parabola. These results, which can be interpreted within a statistical framework, demonstrate that the collective response of the pile contradicts the standard elastic predictions and supports a diffusive description of stress transmission. We expect that these findings will be applicable to problems in soil mechanics, such as the behaviour of cohesionless soils or sand piles.

  8. Federal Emergency Management Information System (FEMIS) system administration guide. Version 1.2

    Energy Technology Data Exchange (ETDEWEB)

    Burford, M.J.; Burnett, R.A.; Curtis, L.M. [and others

    1996-05-01

    The Federal Emergency Management Information System (FEMIS) is an emergency management planning and analysis tool that is being developed under the direction of the US Army Chemical biological Defense Command. The FEMIS System Administration Guide defines FEMIS hardware and software requirements and gives instructions for installing the FEMIS system package. System administrators, database administrators, and general users can use this guide to install, configure, and maintain the FEMIS client software package. This document provides a description of the FEMIS environment; distribution media; data, communications, and electronic mail servers; user workstations; and system management.

  9. ATLAS TDAQ System Administration: evolution and re-design

    Science.gov (United States)

    Ballestrero, S.; Bogdanchikov, A.; Brasolin, F.; Contescu, C.; Dubrov, S.; Fazio, D.; Korol, A.; Lee, C. J.; Scannicchio, D. A.; Twomey, M. S.

    2015-12-01

    The ATLAS Trigger and Data Acquisition system is responsible for the online processing of live data, streaming from the ATLAS experiment at the Large Hadron Collider at CERN. The online farm is composed of ∼3000 servers, processing the data read out from ∼100 million detector channels through multiple trigger levels. During the two years of the first Long Shutdown there has been a tremendous amount of work done by the ATLAS Trigger and Data Acquisition System Administrators, implementing numerous new software applications, upgrading the OS and the hardware, changing some design philosophies and exploiting the High- Level Trigger farm with different purposes. The OS version has been upgraded to SLC6; for the largest part of the farm, which is composed of net booted nodes, this required a completely new design of the net booting system. In parallel, the migration to Puppet of the Configuration Management systems has been completed for both net booted and local booted hosts; the Post-Boot Scripts system and Quattor have been consequently dismissed. Virtual Machine usage has been investigated and tested and many of the core servers are now running on Virtual Machines. Virtualisation has also been used to adapt the High-Level Trigger farm as a batch system, which has been used for running Monte Carlo production jobs that are mostly CPU and not I/O bound. Finally, monitoring the health and the status of ∼3000 machines in the experimental area is obviously of the utmost importance, so the obsolete Nagios v2 has been replaced with Icinga, complemented by Ganglia as a performance data provider. This paper serves for reporting of the actions taken by the Systems Administrators in order to improve and produce a system capable of performing for the next three years of ATLAS data taking.

  10. 47 CFR 73.6024 - Transmission standards and system requirements.

    Science.gov (United States)

    2010-10-01

    ... RADIO SERVICES RADIO BROADCAST SERVICES Class A Television Broadcast Stations § 73.6024 Transmission... cause any condition of uncorrectable interference due to radiation of radio frequency energy outside...

  11. Artificial intelligence in the service of system administrators

    International Nuclear Information System (INIS)

    The LHCb online system relies on a large and heterogeneous IT infrastructure made from thousands of servers on which many different applications are running. They run a great variety of tasks: critical ones such as data taking and secondary ones like web servers. The administration of such a system and making sure it is working properly represents a very important workload for the small expert-operator team. Research has been performed to try to automatize (some) system administration tasks, starting in 2001 when IBM defined the so-called “self objectives” supposed to lead to “autonomic computing”. In this context, we present a framework that makes use of artificial intelligence and machine learning to monitor and diagnose at a low level and in a non intrusive way Linux-based systems and their interaction with software. Moreover, the multi agent approach we use, coupled with an “object oriented paradigm” architecture should increase our learning speed a lot and highlight relations between problems.

  12. Artificial intelligence in the service of system administrators

    Science.gov (United States)

    Haen, C.; Barra, V.; Bonaccorsi, E.; Neufeld, N.

    2012-12-01

    The LHCb online system relies on a large and heterogeneous IT infrastructure made from thousands of servers on which many different applications are running. They run a great variety of tasks: critical ones such as data taking and secondary ones like web servers. The administration of such a system and making sure it is working properly represents a very important workload for the small expert-operator team. Research has been performed to try to automatize (some) system administration tasks, starting in 2001 when IBM defined the so-called “self objectives” supposed to lead to “autonomic computing”. In this context, we present a framework that makes use of artificial intelligence and machine learning to monitor and diagnose at a low level and in a non intrusive way Linux-based systems and their interaction with software. Moreover, the multi agent approach we use, coupled with an “object oriented paradigm” architecture should increase our learning speed a lot and highlight relations between problems.

  13. Study for wireless power transmission of nuclear robot system

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jongseog [Central Research Institute of Korea Hydro and Nuclear Power Co., Daejeon (Korea, Republic of)

    2013-05-15

    Gasoline engine or electric motor is generally used for driving power of working. Gasoline tank is uncomfortable to carry. Battery capacity does not sustain long time working. Frequent moving back of robot to power charger or refueling tank is inconvenient. Long power cable connection occur winding problem if there are complex structures in walking way. We need some solution for continuous supply of robot energy at the free moving condition of robot. 'Wireless power transmission' is one of the solutions. Some experiment result to transmit wireless power to moving robot is described herein. To find possible wireless power transmission method for nuclear robot, wireless power transmission tests were performed. As result of these tests, it was confirmed that wireless power transmission by using dipole and mat type magnetic induction were possible. As result of flying robot experiment, it was realized that development of light weight core for receiver and wave reflection device for high directional transmitter are necessary for practical use of the dipole type wireless power transmission. Small size core and high directional transmitter will be next target. Mat type wireless power transmission is regarded as useful for robot power charging station in the inside containment.

  14. Study for wireless power transmission of nuclear robot system

    International Nuclear Information System (INIS)

    Gasoline engine or electric motor is generally used for driving power of working. Gasoline tank is uncomfortable to carry. Battery capacity does not sustain long time working. Frequent moving back of robot to power charger or refueling tank is inconvenient. Long power cable connection occur winding problem if there are complex structures in walking way. We need some solution for continuous supply of robot energy at the free moving condition of robot. 'Wireless power transmission' is one of the solutions. Some experiment result to transmit wireless power to moving robot is described herein. To find possible wireless power transmission method for nuclear robot, wireless power transmission tests were performed. As result of these tests, it was confirmed that wireless power transmission by using dipole and mat type magnetic induction were possible. As result of flying robot experiment, it was realized that development of light weight core for receiver and wave reflection device for high directional transmitter are necessary for practical use of the dipole type wireless power transmission. Small size core and high directional transmitter will be next target. Mat type wireless power transmission is regarded as useful for robot power charging station in the inside containment

  15. Information system for administrating and distributing color images through internet

    Directory of Open Access Journals (Sweden)

    2007-01-01

    Full Text Available The information system for administrating and distributing color images through the Internet ensures the consistent replication of color images, their storage - in an on-line data base - and predictable distribution, by means of a digitally distributed flow, based on Windows platform and POD (Print On Demand technology. The consistent replication of color images inde-pendently from the parameters of the processing equipment and from the features of the programs composing the technological flow, is ensured by the standard color management sys-tem defined by ICC (International Color Consortium, which is integrated by the Windows operation system and by the POD technology. The latter minimize the noticeable differences between the colors captured, displayed or printed by various replication equipments and/or edited by various graphical applications. The system integrated web application ensures the uploading of the color images in an on-line database and their administration and distribution among the users via the Internet. For the preservation of the data expressed by the color im-ages during their transfer along a digitally distributed flow, the software application includes an original tool ensuring the accurate replication of colors on computer displays or when printing them by means of various color printers or presses. For development and use, this application employs a hardware platform based on PC support and a competitive software platform, based on: the Windows operation system, the .NET. Development medium and the C# programming language. This information system is beneficial for creators and users of color images, the success of the printed or on-line (Internet publications depending on the sizeable, predictable and accurate replication of colors employed for the visual expression of information in every activity fields of the modern society. The herein introduced information system enables all interested persons to access the

  16. Public sector administration of ecological economics systems using mediated modeling.

    Science.gov (United States)

    van den Belt, Marjan; Kenyan, Jennifer R; Krueger, Elizabeth; Maynard, Alison; Roy, Matthew Galen; Raphael, Ian

    2010-01-01

    In today's climate of government outsourcing and multiple stakeholder involvement in public sector management and service delivery, it is more important than ever to rethink and redesign the structure of how policy decisions are made, implemented, monitored, and adapted to new realities. The traditional command-and-control approach is now less effective because an increasing amount of responsibility to deliver public goods and services falls on networks of nongovernment agencies. Even though public administrators are seeking new decision-making models in an increasingly more complex environment, the public sector currently only sparsely utilizes Mediated Modeling (MM). There is growing evidence, however, that by employing MM and similar tools, public interest networks can be better equipped to deal with their long-term viability while maintaining the short-term needs of their clients. However, it may require a shift in organizational culture within and between organizations to achieve the desired results. This paper explores the successes and barriers to implementing MM and similar tools in the public sector and offers insights into utilizing them through a review of case studies and interdisciplinary literature. We aim to raise a broader interest in MM and similar tools among public sector administrators at various administrative levels. We focus primarily, but not exclusively, on those cases operating at the interface of ecology and socio-economic systems.

  17. Wavelet Based Fault Detection, Classification in Transmission System with TCSC Controllers

    Directory of Open Access Journals (Sweden)

    G.Satyanarayana,

    2015-08-01

    Full Text Available This paper presents simulation results of the application of distance relays for the protection of transmission systems employing flexible alternating current transmission controllers such as Thyristor Controlled Series Capacitor (TCSC. The complete digital simulation of TCSC within a transmission system is performed in the MATLAB/Simulink environment using the Power System Block set (PSB. This paper presents an efficient method based on wavelet transforms both fault detection and classification which is almost independent of fault impedance, fault location and fault inception angle of transmission line fault currents with FACTS controllers.

  18. Investigate the Performance of LG 00 Mode in Cost Effective Hybrid Radio over Multimode Transmission System

    OpenAIRE

    Pardeep Kaur; Rajbir Kaur

    2014-01-01

    Radio over fiber (RoF) technology composed for apprehension of future high performance integrated networks and future broadband networks. Multimode fiber links can offer a convenient approach for low cost and short Radio over Fiber (RoF) systems. This work is based on the cost effective radio over multimode transmission system (Ro-MMF) for long reach transmission. Error free transmission of 10 Gbps data with 10 GHz radio signal over multimode fiber link successfully demonstrat...

  19. 75 FR 64389 - Proposed Recommendation to the Social Security Administration for Occupational Information System...

    Science.gov (United States)

    2010-10-19

    ... ADMINISTRATION Proposed Recommendation to the Social Security Administration for Occupational Information System... on plans and activities to create an occupational information system tailored specifically for our... System Development Planning. The comment period is open through November 8, 2010. Contact...

  20. Lymphatic filariasis control in Tanzania: effect of six rounds of mass drug administration with ivermectin and albendazole on infection and transmission

    OpenAIRE

    Paul E Simonsen; Yahya A Derua; Kisinza, William N.; Magesa, Stephen M; Malecela, Mwele N.; Pedersen, Erling M

    2013-01-01

    Background Control of lymphatic filariasis (LF) in most countries of sub-Saharan Africa is based on annual mass drug administration (MDA) with a combination of ivermectin and albendazole, in order to interrupt transmission. We present findings from a detailed study on the effect of six rounds of MDA with this drug combination as implemented by the National Lymphatic Filariasis Elimination Programme (NLFEP) in a highly endemic rural area of north-eastern Tanzania. Methods The effect of treatme...

  1. 5 CFR 930.205 - Administrative law judge pay system.

    Science.gov (United States)

    2010-01-01

    ... administrative law judge's annual rate of basic pay to an hourly, daily, weekly, or biweekly rate: (i) To derive... AL-3, an administrative law judge may be paid at the minimum rate A, unless the administrative law... administrative law judge applicant with prior Federal service a higher than minimum rate up to the lowest rate......

  2. Surveillance of systemic autoimmune rheumatic diseases using administrative data.

    Science.gov (United States)

    Bernatsky, S; Lix, L; Hanly, J G; Hudson, M; Badley, E; Peschken, C; Pineau, C A; Clarke, A E; Fortin, P R; Smith, M; Bélisle, P; Lagace, C; Bergeron, L; Joseph, L

    2011-04-01

    There is growing interest in developing tools and methods for the surveillance of chronic rheumatic diseases, using existing resources such as administrative health databases. To illustrate how this might work, we used population-based administrative data to estimate and compare the prevalence of systemic autoimmune rheumatic diseases (SARDs) across three Canadian provinces, assessing for regional differences and the effects of demographic factors. Cases of SARDs (systemic lupus erythematosus, scleroderma, primary Sjogren's, polymyositis/dermatomyositis) were ascertained from provincial physician billing and hospitalization data. We combined information from three case definitions, using hierarchical Bayesian latent class regression models that account for the imperfect nature of each case definition. Using methods that account for the imperfect nature of both billing and hospitalization databases, we estimated the over-all prevalence of SARDs to be approximately 2-3 cases per 1,000 residents. Stratified prevalence estimates suggested similar demographic trends across provinces (i.e. greater prevalence in females-versus-males, and in persons of older age). The prevalence in older females approached or exceeded 1 in 100, which may reflect the high burden of primary Sjogren's syndrome in this group. Adjusting for demographics, there was a greater prevalence in urban-versus-rural settings. In our work, prevalence estimates had good face validity and provided useful information about potential regional and demographic variations. Our results suggest that surveillance of some rheumatic diseases using administrative data may indeed be feasible. Our work highlights the usefulness of using multiple data sources, adjusting for the error in each. PMID:20665025

  3. Performance analysis for optimum transmission and comparison with maximal ratio transmission for MIMO systems with cochannel interference

    Directory of Open Access Journals (Sweden)

    Lin Sheng-Chou

    2011-01-01

    Full Text Available Abstract This article presents the performance analysis of multiple-input/multiple-output (MIMO systems with quadrature amplitude modulation (QAM transmission in the presence of cochannel interference (CCI in nonfading and flat Rayleigh fading environments. The use of optimum transmission (OT and maximum ratio transmission (MRT is considered and compared. In addition to determining precise results for the performance of QAM in the presence of CCI, it is our another aim in this article to examine the validity of the Gaussian interference model in the MRT-based systems. Nyquist pulse shaping and the effects of cross-channel intersymbol interference produced by CCI due to random symbol of the interfering signals are considered in the precise interference model. The error probability for each fading channel is estimated fast and accurately using Gauss quadrature rules which can approximate the probability density function (pdf of the output residual interference. The results of this article indicate that Gaussian interference model may overestimate the effects of interference, particularly, for high-order MRT-based MIMO systems over fading channels. In addition, OT cannot always outperform MRT due to the significant noise enhancement when OT intends to cancel CCI, depending on the combination of the antennas at the transmitter and the receiver, number of interference and the statistical characteristics of the channel.

  4. Experimental characterization of dispersion maps with Raman gain in 160 Gb/s transmission systems

    DEFF Research Database (Denmark)

    Zhenbo, Xu; Seoane, Jorge; Siahlo, Andrei;

    2004-01-01

    We investigate the combined effects of dispersion compensation and Raman amplification in SMF-based transmission span of 160 Gb/s system. The post compensation map shows better power tolerance.......We investigate the combined effects of dispersion compensation and Raman amplification in SMF-based transmission span of 160 Gb/s system. The post compensation map shows better power tolerance....

  5. 47 CFR 74.795 - Digital low power TV and TV translator transmission system facilities.

    Science.gov (United States)

    2010-10-01

    ... translator transmission system facilities. (a) A digital low power TV or TV translator station shall operate... 47 Telecommunication 4 2010-10-01 2010-10-01 false Digital low power TV and TV translator transmission system facilities. 74.795 Section 74.795 Telecommunication FEDERAL COMMUNICATIONS...

  6. Carbon footprint of the Danish electricity transmission and distribution systems

    DEFF Research Database (Denmark)

    Turconi, Roberto; Astrup, Thomas Fruergaard

    , and relevant auxiliary infrastructures. Electricity T&D provided respectively 29 and 17 gCO2e/kWh, mainly related to power losses. Emissions from distribution were larger than those from transmission, because of higher losses and higher complexity and material consumption. Large differences were found between......The electricity sector is among the main sources of greenhouse gas (GHG) emissions; today, those are mainly due to combustion of fossil fuels, but with increasing renewable sources the importance of infrastructures both in electricity generation and in transmission and distribution (T......&D) will likely grow. Several studies are available on renewable energy technologies, but only a few on transmission of electricity, and none on its distribution. This study provides life cycle inventory data for electricity distribution networks, and a life cycle GHG accounting of the Danish T&D networks...

  7. Central amygdala opioid transmission is necessary for increased high-fat intake following 24-h food deprivation, but not following intra-accumbens opioid administration.

    Science.gov (United States)

    Parker, Kyle E; Johns, Howard W; Floros, Ted G; Will, Matthew J

    2014-03-01

    Previous research has demonstrated a dissociation of certain neural mediators that contribute to the increased consumption of a high-fat diet that follows intra-accumbens (Acb) administration of μ-opioid receptor agonists vs. 24-h food deprivation. These two models, both which induce rapid consumption of the diet, have been shown to involve a distributed corticolimbic circuitry, including the amygdala. Specifically, the central amygdala (CeA) has been shown to be involved in high-fat feeding within both opioid and food-deprivation driven models. The present experiments were conducted to examine the more specific role of CeA opioid transmission in mediating high-fat feeding driven by either intra-Acb administration of the μ-opioid agonist d-Ala2-NMe-Phe4-Glyol5-enkephalin (DAMGO) or 24-h home cage food deprivation. Injection of DAMGO into the Acb (0.25 μg/0.5 μl/side) increased consumption of the high-fat diet, but this feeding was unaffected by administration of opioid antagonist, naltrexone (5 μg/0.25 μl/side) administered into the CeA. In contrast, intra-CeA naltrexone administration attenuated high-fat intake driven by 24-h food deprivation, demonstrating a specific role for CeA opioid transmission in high-fat consumption. Intra-CeA naltrexone administration alone had no effect on baseline feeding levels within either feeding model. These findings suggest that CeA opioid transmission mediates consumption of a palatable high-fat diet driven by short-term negative-energy balance (24-h food deprivation), but not intra-Acb opioid receptor activation.

  8. Western Area Power Administration. Combined power system financial statements

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-02-26

    This report presents the results of the independent certified public accountants` audit of the Western Area Power Administration`s combined power system statements of assets, Federal investment and liabilities, and the related combined statements of revenues, expenses and accumulated net revenues, and cash flows. The auditors` report on Westerns internal control structure disclosed three new reportable conditions concerning the lack of: (1) a reconciliation of stores inventory from subsidiary ledgers to summary financial information, (2) communication of interest during construction and related adjustments to interest on Federal investment, and (3) a system to prevent and detect power billing errors. None of the conditions were considered to be material weaknesses. Western provided concurrence and corrective action plans. The auditors` report on Western`s compliance with laws and regulations also disclosed two new instances of noncompliance. Western failed to calculate nonreimbursable expenses in accordance with the Grand Canyon Protection Act and had an unexplained difference in gross Federal investment balances used to calculate interest on Federal investment. Western provided concurrence and corrective action plans for the instances.

  9. Preliminary survey of integrated monitoring system for transmission liens. Sodensen sogo kanshi system no yobi kento

    Energy Technology Data Exchange (ETDEWEB)

    Sasano, Takao; Nishiyama, Fumihiko

    1988-04-01

    The integrated monitoring system of transmission lines utilizing ground wire with built-in optical fibres(OPGW) which was put to practical use was surveyed. The overhead transmission lines have potential to be impeded supply owing to the line exposure to severe natural envioronment or by the change of surrounding environment such as trees, buildings under lines and ground or by deterioration of equipments. This report describes the system to monitor integrally the transmission lines by using OPGW or sensor technology to maintain and operate with higher reliability and lower cost and to reflect in the design, except the conventional maintenance and checking. The effect to foresee and prevent accidents is expected from this system, but the regional difference must be considered. This system can provide continously reliable monitoring, collection of maintenance informations and operation support and further can provide accident informations to be used in the design through the evaluation. It is necessary to use highly reliable repeaters for optical informations, protect instruments under intense field, prevent malfunction and develop the auto-movable robot for taking picture and local weather prediction system in order to realize this system. (5 figs, 6 tabs, 8 refs)

  10. Tuning of JET transmission line/antenna system during ICRH

    International Nuclear Information System (INIS)

    The launched toroidal wave spectrum for ICRH and ICRH current drive is controlled by the phasing of the antenna currents. This causes imbalance in the transmission lines, which makes it more difficult to use the full power of the ICRH generators. Further, the generators are sensitive to the amount of reflected power. To reduce the amount of reflected power the transmission lines have to be constantly tuned. To study the tuning three models of the antenna are developed and compared with experimental results. A method is suggested which enables better usage of the generated power using a power correction unit to evenly distribute the power load between the generators. 4 refs, 24 figs

  11. Parameter design and performance analysis of zero inertia continuously variable transmission system

    Institute of Scientific and Technical Information of China (English)

    胡建军; 吉毅; 晏玖江

    2015-01-01

    In order to solve the problem of weak power performance of vehicle equipped with continuously variable transmission (CVT) system working under transient operating conditions, a new CVT equipped with planetary gear mechanism and flywheel was researched, a design method of transmission parameter optimization was proposed, and the comprehensive matching control strategy was established for the new transmission system. Fuzzy controllers for throttle opening and CVT speed ratio were designed, and power performance and fuel economy of both vehicles respectively equipped with conventional CVT system and new transmission system wrere compared and analyzed by simulation. The results show that power performance and fuel economy of the vehicle equipped with new transmission system are better than that equipped with conventional CVT, thus the rationality of the parameter design method and control algorithm are verified.

  12. Numerical and experimental analysis of structure-borne sound transmission in coupled systems

    Science.gov (United States)

    Cao, Xiaodong; Backhaus, Stefan-Georg; Scheidl, Rudolf; Rembe, Christian

    2016-06-01

    The vibration-power transmission is often applied as a quantity to describe the structure-borne sound transmission in a vibration system and is, therefore, of major interest for machine manufactures. Well-developed theories about power transfer for multi-point coupled systems exist, especially, for structure-borne sound characterization. However, a theoretic analysis of area coupled systems is still a research topic because a direct measurement of vibration-power transmission in the contact interface for such systems is not possible. This paper introduces a strategy to investigate the vibration power transmission in such systems by using a finite element model which is updated by the so-called "model updating technique" based on experimental modal analysis, which is performed by a laser scanning Doppler vibrometer, in opposite to conventionally by accelerometer. The strategy is demonstrated on a simple test assembly and the estimated power transmission is derived.

  13. Design and Realization of Phased Array Radar Optical Fiber Transmission System

    Institute of Scientific and Technical Information of China (English)

    HU Shan-qing; LIU Feng; LONG Teng

    2007-01-01

    One optical fiber transmission system is designed.The modularization optical fiber transmission adapters were utilized in the system,so the system structure could be flexibly scalable.The sub-array adapter and signal processor adapter were designed and realized utilizing the new field programmable gate array (FPGA) which could drive the optical transceiver.The transmission agreement was designed based on the data stream.In order to solve the signal synchronization problem of the optical fiber transmitted phased array radar,a method named synchronous clock was designed.The fiber transmission error code rate of the system was zero with an experimental transmission velocity of 800 Mbit/s.The phased array radar system has detected the airplane target,thus validated the feasibility of the design method.

  14. PROXY-BASED PATCHING STREAM TRANSMISSION STRATEGY IN MOBILE STREAMING MEDIA SYSTEM

    Institute of Scientific and Technical Information of China (English)

    Liao Jianxin; Lei Zhengxiong; Ma Xutao; Zhu Xiaomin

    2006-01-01

    A mobile transmission strategy, PMPatching (Proxy-based Mobile Patching) transmission strategy is proposed, it applies to the proxy-based mobile streaming media system in Wideband Code Division Multiple Access (WCDMA) network. Performance of the whole system can be improved by using patching stream to transmit anterior part of the suffix that had been played back, and by batching all the demands for the suffix arrived in prefix period and patching stream transmission threshold period. Experimental results show that this strategy can efficiently reduce average network transmission cost and number of channels consumed in central streaming media server.

  15. Post-Mass Drug Administration Transmission Assessment Survey for Elimination of Lymphatic Filariasis in La Ciénaga, Dominican Republic.

    Science.gov (United States)

    Noland, Gregory S; Blount, Stephen; Gonzalez, Manuel

    2015-12-01

    The Dominican Republic is one of four remaining countries in the Americas with lymphatic filariasis (LF). Annual mass drug administration (MDA) with albendazole and diethylcarbamazine was conducted in La Ciénaga, an impoverished urban barrio in Santo Domingo, from 2004 to 2006. Eight years after the last MDA, a transmission assessment survey (TAS) was conducted in November-December 2014 to determine if LF transmission remains absent. Of 815 first and second grade primary school students (mean age: 6.51 years; range 5-9) tested by immunochromatographic test (ICT), zero (0.0%) were positive. This is below the TAS critical cutoff of nine, indicating that the area "passed" TAS and that transmission remains interrupted in La Ciénaga. Importantly, this also provides evidence that three rounds of effective (> 65% coverage) MDA, likely aided by environmental improvements and periodic school-based albendazole monotherapy MDA, achieved interruption of LF transmission from a relatively low-transmission setting. PMID:26503279

  16. A Study on System Availability Vs System Administration Efforts with Mathematical Models

    Institute of Scientific and Technical Information of China (English)

    郑建德

    2003-01-01

    Two mathematical models are developed in this paper to study the effectiveness of system administration efforts on the improvement of system availability, based on the assumption that there exists a transitional state for a computer system in operation before it is brought down by some hardware or software problems and with intensified system administration efforts, it is possible to discover and fix the problems in time to bring the system back to normal state before it is down. Markov chain is used to simulate the transition of system states. A conclusion is made that increasing system administration efforts may be a cost-effective way to meet the requirements for moderate improvement on system availability, but higher demand on this aspect still has to be met by advanced technologies.

  17. Virtual Pipeline System Testbed to Optimize the U.S. Natural Gas Transmission Pipeline System

    Energy Technology Data Exchange (ETDEWEB)

    Kirby S. Chapman; Prakash Krishniswami; Virg Wallentine; Mohammed Abbaspour; Revathi Ranganathan; Ravi Addanki; Jeet Sengupta; Liubo Chen

    2005-06-01

    The goal of this project is to develop a Virtual Pipeline System Testbed (VPST) for natural gas transmission. This study uses a fully implicit finite difference method to analyze transient, nonisothermal compressible gas flow through a gas pipeline system. The inertia term of the momentum equation is included in the analysis. The testbed simulate compressor stations, the pipe that connects these compressor stations, the supply sources, and the end-user demand markets. The compressor station is described by identifying the make, model, and number of engines, gas turbines, and compressors. System operators and engineers can analyze the impact of system changes on the dynamic deliverability of gas and on the environment.

  18. Non-systemic transmission of tick-borne diseases: A network approach

    Science.gov (United States)

    Ferreri, Luca; Bajardi, Paolo; Giacobini, Mario

    2016-10-01

    Tick-borne diseases can be transmitted via non-systemic (NS) transmission. This occurs when tick gets the infection by co-feeding with infected ticks on the same host resulting in a direct pathogen transmission between the vectors, without infecting the host. This transmission is peculiar, as it does not require any systemic infection of the host. The NS transmission is the main efficient transmission for the persistence of the tick-borne encephalitis virus in nature. By describing the heterogeneous ticks aggregation on hosts through a bipartite graphs representation, we are able to mathematically define the NS transmission and to depict the epidemiological conditions for the pathogen persistence. Despite the fact that the underlying network is largely fragmented, analytical and computational results show that the larger is the variability of the aggregation, and the easier is for the pathogen to persist in the population.

  19. ATLAS TDAQ System Administration: evolution and re-design

    CERN Document Server

    Ballestrero, Sergio; The ATLAS collaboration; Brasolin, Franco; Contescu, Alexandru Cristian; Dubrov, Sergei; Fazio, Daniel; Korol, Aleksandr; Lee, Christopher Jon; Scannicchio, Diana; Twomey, Matthew Shaun

    2015-01-01

    The ATLAS Trigger and Data Acquisition (TDAQ) system is responsible for the online processing of live data, streaming from the ATLAS experiment at the Large Hadron Collider (LHC) at CERN. The online farm is composed of $\\sim 3000$ servers, processing the data readout from $\\sim 100$ million detector channels through multiple trigger levels. During the two years of the first Long Shutdown (LS1) there has been a tremendous amount of work done by the ATLAS TDAQ System Administrators, implementing numerous new software applications, upgrading the OS and the hardware, changing some design philosophies and exploiting the High Level Trigger farm with different purposes. The OS version has been upgraded to SLC6; for the largest part of the farm, which is composed by net booted nodes, this required a completely new design of the net booting system. In parallel, the migration to Puppet of the Configuration Management systems has been completed for both net booted and local booted hosts; the Post-Boot Scripts system and...

  20. Initial assessment: electromagnetic compatibility aspects of proposed SPS Microwave Power Transmission System (MPTS) operations

    Energy Technology Data Exchange (ETDEWEB)

    1978-02-01

    An analysis of major concerns with regard to the effects on radio and electronic systems by the proposed Microwave Power Transmission System for transmitting power from a satellite solar power station to earth is presented. (LCL)

  1. Modeling and simulation of the transmission system for a chainless electric bicycle

    OpenAIRE

    Garcia Farreny, Alex

    2015-01-01

    This project, entitled Modeling and Simulation of the Transmission System for a Chainless Electric Bicycle, consists in the design of the controllers’ logics governing a chainless electric bicycle’s transmission in order to accomplish certain behavior in front of inputs such as pedaling torque, slope gradient, frontal wind, gear selected, etc. To better understand it, a chainless electric bicycle replaces the conventional mechanical transmission (chain) by two electric mac...

  2. Analysis of transmission efficiency of the superconducting resonance coil according the materials of cooling system

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yu Kyeong; Hwang, Jun Won; Choi, Hyo Sang [Chosun University, Gwangju (Korea, Republic of)

    2016-03-15

    The wireless power transfer (WPT) system using a magnetic resonance was based on magnetic resonance coupling of the transmission and the receiver coils. In these system, it is important to maintain a high quality-factor (Q-factor) to increase the transmission efficiency of WPT system. Our research team used a superconducting coil to increase the Q-factor of the magnetic resonance coil in WPT system. When the superconductor is applied in these system, we confirmed that transmission efficiency of WPT system was higher than normal conductor coil through a preceding study. The efficiency of the transmission and the receiver coil is affected by the magnetic shielding effect of materials around the coils. The magnetic shielding effect is dependent on the type, thickness, frequency, distance, shape of materials. Therefore, it is necessary to study the WPT system on the basis of these conditions. In this paper, the magnetic shield properties of the cooling system were analyzed using the High-Frequency Structure Simulation (HFSS, Ansys) program. We have used the shielding materials such as plastic, aluminum and iron, etc. As a result, when we applied the fiber reinforced polymer (FRP), the transmission efficiency of WPT was not affected because electromagnetic waves went through the FRP. On the other hand, in case of a iron and aluminum, transmission efficiency was decreased because of their electromagnetic shielding effect. Based on these results, the research to improve the transmission efficiency and reliability of WPT system is continuously necessary.

  3. 77 FR 4292 - Midwest Independent Transmission System Operator, Inc.; Notice of Filing of Response to Data Request

    Science.gov (United States)

    2012-01-27

    ... Energy Regulatory Commission Midwest Independent Transmission System Operator, Inc.; Notice of Filing of Response to Data Request Take notice that on January 19, 2012, Midwest Independent Transmission System... representatives of Transmission Owners and Non-Transmission Owners, MISO Advisory Committee participants, and...

  4. Study on protection scheme using SFCL for transmission system with Thyristor Controlled Series Capacitor

    Science.gov (United States)

    Huh, Jae-Sun; Moon, Won-Sik; Kim, Jae-Chul

    2015-11-01

    In this paper, we propose a protection scheme using a superconducting fault current limiter (SFCL) for the power transmission system with Thyristor Controlled Series Capacitor (TCSC). TCSC can lead effectiveness such as power flow control, increase in transmission capacity, and improvement for system transient phenomena. But, because this has same effect to the reducing series impedances in transmission system, there are serious problem such as increase in fault current, transient stability deterioration and series voltage stress of TCSC in the transmission line. The proposed protection scheme using the SFCL into TCSC configuration can mitigate these problems. In addition, SFCL can be expected to protect the TCSC from a large transient current generated by lightning or switching surge in power transmission system. To verify the effect of the proposed protection scheme, PSCAD/EMTDC is used. From simulation result, we had good results for fault current limitation and insulating protection of TCSC.

  5. Grey Problems of a Mechanical Transmission System in a Reliability Study

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    In the light of the Grey characters of reliability on a mechanical transmission system,Grey problems that could assist in the study on mechanical transmission system were analyzed.For example, the factors of time function, the factors of environment and the factors of people have some relationships with the system in this paper: And then, the methods and procedures,which were based upon the theory of Grey system, were elaborated.

  6. Academic Management and Administration System Reform in Higher Education Institutions

    Institute of Scientific and Technical Information of China (English)

    Xiang Xianming

    2006-01-01

    Reforms in colleges and universities should promote the humanistic character of higher education-rather than simply serve for pure economic production--but also observe the sacred mission of transmiting and creating culture and knowledge.wim these two possessing momentous differences.These then demand rationality in academic management to guard against declination toward dehumanization or bureaucracy.Thus.the relationship between academic power and administrative power must be harmonized,and a reasonable equilibrium must be guaranteed.An academic management idea of power in learning is particularly emphasized to overcome the false polarity of managerism,straightforwardly reducing complicated academic operations to a kind of economic prosecution,hence truly promoting the function of a higher education system.

  7. Transmission needs across a fully renewable European power system

    CERN Document Server

    Rodriguez, Rolando A; Andresen, Gorm B; Heide, Dominik; Greiner, Martin

    2013-01-01

    The residual load and excess power generation of 27 European countries with a 100% penetration of variable renewable energy sources are explored in order to quantify the benefit of power transmission between countries. Estimates are based on extensive weather data, which allows for modelling of hourly mismatches between the demand and renewable generation from wind and solar photovoltaics. For separated countries, balancing is required to cover around 24% of the total annual energy consumption. This number can be reduced down to 15% once all countries are networked together with uncon- strained interconnectors. The reduction represents the maximum possible benefit of transmission for the countries. The total Net Transfer Capacity of the unconstrained interconnectors is roughly twelve times larger than current values. However, constrained interconnector capacities six times larger than the current values are found to provide 97% of the maximum possible benefit of cooperation. This motivates a detailed investig...

  8. Linearization Technologies for Broadband Radio-Over-Fiber Transmission Systems

    OpenAIRE

    Xiupu Zhang; Ran Zhu; Dongyan Shen; Taijun Liu

    2014-01-01

    Linearization technologies that can be used for linearizing RoF transmission are reviewed. Three main linearization methods, i.e. electrical analog linearization, optical linearization, and electrical digital linearization are presented and compared. Analog linearization can be achieved using analog predistortion circuits, and can be used for suppression of odd order nonlinear distortion components, such as third and fifth order. Optical linearization includes mixed-polarization, dual-wavelen...

  9. Transmission system planning in competitive and restructured environment: part-1

    International Nuclear Information System (INIS)

    In restructured environment, competitive markets expose transmission planners to new uncertainties. These are handled using a decision analysis approach whose key contribution is quantifying, minimizing risk with least cost effective plans. Power utility worldwide is under the process of disintegration these days. Now, it is the need of time that existing trends should be changed with the new ones in competitive restructured environment to escape from the present situation and enter into a new set up which is more reliable both from service and stability point of view. Traditionally, transmission planning used to be done by a state owned vertically integrated utility. This type of control on utilities is going to be diminished in coming restructured environment. In restructured environment, open access and on non-discriminatory basis clearly explains its importance including the aspects which gives better and more reliable and stable service in addition to future expansion provisions along with the role of private sector, but not affecting the country's security at any cost. A proper regulatory body must check the activities of private set up transmission planners and also it is must be for private sector to act upon the rules provided by the regulatory authority of that country. The are bound to act upon the guidelines provided by that Regulatory Authority. (author)

  10. Linearization Technologies for Broadband Radio-Over-Fiber Transmission Systems

    Directory of Open Access Journals (Sweden)

    Xiupu Zhang

    2014-11-01

    Full Text Available Linearization technologies that can be used for linearizing RoF transmission are reviewed. Three main linearization methods, i.e. electrical analog linearization, optical linearization, and electrical digital linearization are presented and compared. Analog linearization can be achieved using analog predistortion circuits, and can be used for suppression of odd order nonlinear distortion components, such as third and fifth order. Optical linearization includes mixed-polarization, dual-wavelength, optical channelization and the others, implemented in optical domain, to suppress both even and odd order nonlinear distortion components, such as second and third order. Digital predistortion has been a widely used linearization method for RF power amplifiers. However, digital linearization that requires analog to digital converter is severely limited to hundreds of MHz bandwidth. Instead, analog and optical linearization provide broadband linearization with up to tens of GHz. Therefore, for broadband radio over fiber transmission that can be used for future broadband cloud radio access networks, analog and optical linearization are more appropriate than digital linearization. Generally speaking, both analog and optical linearization are able to improve spur-free dynamic range greater than 10 dB over tens of GHz. In order for current digital linearization to be used for broadband radio over fiber transmission, the reduced linearization complexity and increased linearization bandwidth are required. Moreover, some digital linearization methods in which the complexity can be reduced, such as Hammerstein type, may be more promising and require further investigation.

  11. Federal Emergency Management Information System (FEMIS) system administration guide. Version 1.3

    Energy Technology Data Exchange (ETDEWEB)

    Burford, M.J.; Burnett, R.A.; Downing, T.R. [and others

    1996-12-01

    The Federal Emergency Management Information System (FEMIS) is an emergency management planning and analysis tool that was developed by the (Pacific Northwest National Laboratory) (PNNL) under the direction of the U.S. Army Chemical Biological Defense Command. The FEMIS System Administration Guide defines FEMIS hardware and software requirements and gives instructions for installing the FEMIS software package. 91 This document also contains information on the following: software installation for the FEMIS data servers, communication server, mail server, and the emergency management workstations; distribution media loading and FEMIS installation validation and troubleshooting; and system management of FEMIS users, login, privileges, and usage. The system administration utilities (tools), available in the FEMIS client software, are described for user accounts and site profile. This document also describes the installation and use of system and database administration utilities that will assist in keeping the FEMIS system running in an operational environment.

  12. Line Capacity Expansion and Transmission Switching in Power Systems With Large-Scale Wind Power

    DEFF Research Database (Denmark)

    Villumsen, Jonas Christoffer; Bronmo, Geir; Philpott, Andy B.

    2013-01-01

    In 2020 electricity production from wind power should constitute nearly 50% of electricity demand in Denmark. In this paper we look at optimal expansion of the transmission network in order to integrate 50% wind power in the system, while minimizing total fixed investment cost and expected cost...... of power generation. We allow for active switching of transmission elements to reduce congestion effects caused by Kirchhoff's voltage law. Results show that actively switching transmission lines may yield a better utilization of transmission networks with large-scale wind power and increase wind power...

  13. The integration of renewable energy sources into electric power transmission systems

    Energy Technology Data Exchange (ETDEWEB)

    Barnes, P.R.; Dykas, W.P.; Kirby, B.J.; Purucker, S.L. [Oak Ridge National Lab., TN (United States); Lawler, J.S. [Univ. of Tennessee, Knoxville, TN (United States)

    1995-07-01

    Renewable energy technologies such as photovoltaics, solar thermal power plants, and wind turbines are nonconventional, environmentally attractive sources of energy that can be considered for electric power generation. Many of the areas with abundant renewable energy resources (very sunny or windy areas) are far removed from major load centers. Although electrical power can be transmitted over long distances of many hundreds of miles through high-voltage transmission lines, power transmission systems often operate near their limits with little excess capacity for new generation sources. This study assesses the available capacity of transmission systems in designated abundant renewable energy resource regions and identifies the requirements for high-capacity plant integration in selected cases. In general, about 50 MW of power from renewable sources can be integrated into existing transmission systems to supply local loads without transmission upgrades beyond the construction of a substation to connect to the grid. Except in the Southwest, significant investment to strengthen transmission systems will be required to support the development of high-capacity renewable sources of 1000 MW or greater in areas remote from major load centers. Cost estimates for new transmission facilities to integrate and dispatch some of these high-capacity renewable sources ranged from several million dollars to approximately one billion dollars, with the latter figure an increase in total investment of 35%, assuming that the renewable source is the only user of the transmission facility.

  14. Communication protocol in chassis detecting wireless transmission system based on WiFi

    Science.gov (United States)

    In chassis detecting wireless transmission system, the wireless network communication protocol plays a key role in the information exchange and synchronization between the host and chassis PDA. This paper presents a wireless network transmission protocol based on TCP/IP which makes the rules of info...

  15. State of the art analysis of online fault location on AC cables in underground transmission systems

    DEFF Research Database (Denmark)

    Jensen, Christian Flytkjær; Gudmundsdottir, Unnur Stella; Bak, Claus Leth

    2011-01-01

    In this article the state of the art research for online fault location on cross-bonded transmission level cables is presented. The article is focused on the difficulties in using the algorithms developed for OHL-systems and distribution cables directly on cross-bonded transmission cables...

  16. Joint impact of quantization and clipping on single- and multi-carrier block transmission systems

    NARCIS (Netherlands)

    Yang, H.; Schenk, T.C.W.; Smulders, P.F.M.; Fledderus, E.R.

    2008-01-01

    This work investigates the joint impact of quantization and clipping, caused by analog-to-digital converters (ADCs) with low bit resolutions, on single- and multi-carrier block transmission systems in wireless multipath environments. We consider single carrier block transmission with frequency domai

  17. Wideband Analog Transmission System Based on the External Intensity Electro-Optic Modulator

    Directory of Open Access Journals (Sweden)

    Jiri Svarny

    2016-01-01

    Full Text Available The work deals with design and integration of an analog electro-optic transmission system suitable for some specialized tasks of diagnostics and measurements. The system is based on principle of external intensity modulation of fiber guided laser radiation. Besides wideband and almost lossless transmission the system tolerates extreme length of the transmitting medium and ensures ultimate galvanic barrier between the input and output.

  18. Performance Analysis of a Voltage Source Converter (VSC based HVDC Transmission System under Faulted Conditions

    Directory of Open Access Journals (Sweden)

    Amiri RABIE

    2009-12-01

    Full Text Available Voltage Source Converter (VSC based HVDC transmission technology hasbeen selected as the basis for several recent projects due to its controllability,compact modular design, ease of system interface, and low environmentalimpact. This paper investigates the dynamic performance of a 200MW,±100kV VSC-HVDC transmission system under some faulted conditionsusing MATLAB/Simulink. Simulation results confirm the satisfactoryperformance of the proposed system under active and reactive powervariations and fault conditions.

  19. Noise and signal interference in optical fiber transmission systems an optimum design approach

    CERN Document Server

    Bottacchi, Stefano

    2008-01-01

    A comprehensive reference to noise and signal interference in optical fiber communications Noise and Signal Interference in Optical Fiber Transmission Systems is a compendium on specific topics within optical fiber transmission and the optimization process of the system design. It offers comprehensive treatment of noise and intersymbol interference (ISI) components affecting optical fiber communications systems, containing coverage on noise from the light source, the fiber and the receiver. The ISI is modeled with a statistical approach, leading to new useful computational m

  20. Effect of energy harvesting network reactive support on transmission system voltage performance

    OpenAIRE

    Cuffe, Paul; Smith, Paul; Keane, Andrew

    2011-01-01

    It is common to operate distributed generators (DGs) at fixed inductive power factors to overcome voltage rise constraints on distribution networks. This approach increases distribution system reactive power demand, which may strain transmission system reactive power resources at times of system-wide high DG output, particularly if such output displaces synchronous generators. If a number of adjacent DGs are connected to a transmission node in a clustered fashion via a dedicated energy ha...

  1. Transmission prices in the electric system. Technical constraints and economic efficiency

    International Nuclear Information System (INIS)

    This article analyses the two main models at the core of today's theoretical discussion on transmission pricing in electricity sectors under competition. The first aim of the paper is showing how technical constraints that characterise transmission systems may affect energy production and transmission and therefore the definition of the price system for using the electric grid. The second aim of the paper is showing how it is possible to suggest solutions, although not free from limitations, that can be used for an efficient management of electric systems characterised by generation and consumption sectors under competition

  2. Research and Development of Engine-Generator Set Control System for Tracked Vehicle Electric Transmission System

    Institute of Scientific and Technical Information of China (English)

    HUANG Ying; HUANG Qian; SUN Feng-chun; LIU Bo-lan; LIU Jia

    2007-01-01

    As an energy generating equipment, the engine-generator set supplies power to the electric transmission. Therefore, its control is one of the key technologies of electric vehicles. Based on the discussion about the demands to the engine-generator set in tracked vehicles, the detailed function of engine-generator and the control strategy are determined. The hardware and software of the control system are also developed and tested in a prototype vehicle. The experiment results show that the control system has good reliability and can satisfy the power requirements of vehicles under all operating conditions.

  3. Planning the future of JPL's management and administrative support systems around an integrated database

    Science.gov (United States)

    Ebersole, M. M.

    1983-01-01

    JPL's management and administrative support systems have been developed piece meal and without consistency in design approach over the past twenty years. These systems are now proving to be inadequate to support effective management of tasks and administration of the Laboratory. New approaches are needed. Modern database management technology has the potential for providing the foundation for more effective administrative tools for JPL managers and administrators. Plans for upgrading JPL's management and administrative systems over a six year period evolving around the development of an integrated management and administrative data base are discussed.

  4. Portable Automated Oxygen Administration System for hypoxaemic patients

    OpenAIRE

    Alzoubi, Khawla; Alguraan, Ziyad; Omar M. Ramahi

    2016-01-01

    Oxygen is a lifesaving medication that should be offered with an administration to a patient who suffers from oxygen deficiency to avoid toxic effects of excessive oxygen supplement as well as to minimize the exposure to hypoxaemia. This work aims to automate the process of administering oxygen delivery in order to extend the continuous oxygen administration process beyond the IC units, reduce the cost of oxygen administration in terms of well-trained health care providers and equipment, prol...

  5. Modeling of leak detection system for high pressure transmission system of natural gas

    International Nuclear Information System (INIS)

    Gas Industry can be considered as one of the most important industries in the economy of any country. Safe Transportation of Gas is thus considered to be vital because interruption of Supply of Gas to consumers not only causes domestic problems but also loss of revenue to country. Now most of power generation Sector has switched over their system to Natural Gas. So, interruption of supply to this sector can cause a lot of problems. This paper has provided assessment of technology approach and formulated this approach for Leak Detection Model in High Pressure Transmission system for current and future operations, which will improve the efficiency of any transmission company to a great extent. This model can be extremely helpful in conditions of Rupture Emergencies or Leakage because of corrosive conditions of Pipeline to manage the situation of resources in pipeline network. Any exceptional readings or messages should alert the user to the fact that something is wrong with the system. Such a system helps a lot in the safe and efficient management of pipeline network. The data and information provided by the Leak Detection System applications will allow for efficient and safe pipeline operation maximizing profitability over the pipeline's service lifetime. (author)

  6. A Study on the Application for Enhancing the Transmission Capability of the KEPCO Power System

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Han; Kwon, Tea Won; Whang, Jong Young; Lee, Gun Joon; Kim, Tae Hoon; Chang, Byung Hoon; Min, Wan Ki [Korea Electric Power Research Institute, Taejon (Korea, Republic of); Park, Young Moon; Park, Jong Gun [Seoul National University, Seoul (Korea, Republic of); Kim, Gun Joong [Chungnam National University, Taejon (Korea, Republic of); Oh, Tae Kwu; Choi, Kwu Hyung [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1996-12-31

    Investigation of stability for power system in 2000 year and 2006 year by using the analysis of real power system. Comparative investigation of the conventional transmission line upgrading methods such as HVDC, HOP, new conductor scheme. Investigation of FACTS, the recent transmission line upgrading method, with respect to the aspect of technique and cost and effect analysis when this method is applied to real power system. Development of the evaluation method of transmission type that should be considered when above method is applied to real power system with respect to aspect of technique and cost. Development of a long-range plan for the transmission capacity upgrading and the evaluation method of reliability. (author).

  7. Transmission system planning in competitive and restructured environment - case study: part-1

    International Nuclear Information System (INIS)

    In continuation with previous paper, it is obvious that transmission planning in competitive and restructured environment is very important to have an efficient and economical power system / transmission network in changing trends globally. The recommendations give in part of this paper are implemented on a case study. The conclusions drawn by the study done in part clearly gives positive results in favor of transmission system planning in competitive and restructured environment to have open access and on non-discriminatory basis including the features of wheeling transactions and controlled by the regulatory body to monitor the activities of private set up specially from defense point of view and reliability and stability of the system. The results obtained in previous paper are going to be implemented on a study case. Results of application of transmission system planning in competitive and restructured environment is given at the end. (author)

  8. Training-based Channel Estimation for Signal Equalization and OPM in 16-QAM Optical Transmission Systems

    DEFF Research Database (Denmark)

    Pittalà, Fabio; Hauske, Fabian N.; Ye, Yabin;

    2012-01-01

    Efficient channel estimation for signal equalization and OPM based on short CAZAC sequences with QPSK and 8PSK constellation formats is demonstrated in a 224-Gb/s PDM 16-QAM optical linear transmission system....

  9. System Design for Ocean Sensor Data Transmission Based on Inductive Coupling

    Science.gov (United States)

    Xu, Ming; Liu, Fei; Zong, Yuan; Hong, Feng

    Ocean observation is the precondition to explore and utilize ocean. How to acquire ocean data in a precise, efficient and real-time way is the key question of ocean surveillance. Traditionally, there are three types of methods for ocean data transmission: underwater acoustic, GPRS via mobile network and satellite communication. However, none of them can meet the requirements of efficiency, accuracy, real-time and low cost at the same time. In this paper, we propose a new wireless transmission system for underwater sensors, which established on FGR wireless modules, combined with inductive coupling lab and offshore experiments confirmed the feasibility and effectiveness of the proposed wireless transmission system.

  10. Electrical transmission systems and smart grids selected entries from the encyclopedia of sustainability science and technology

    CERN Document Server

    Begovic, Miroslav M

    2012-01-01

    Electric transmission networks are among the largest human-made engineering systems: For example, the transmission network in the United States covers over 300,000 km of lines and is served by 500 companies (electric utilities). In sharp contrast to the very incremental developments of the last century, transmission and control technologies experienced a major breakthrough at the beginning of the 21st century. The rapid growth of new energy generation technologies (renewables), significant advances in information processing applied to system monitoring, planning, operation, control, and protec

  11. Transmission Dynamics of a Driven Two-Level System Dissipated by Leads

    Institute of Scientific and Technical Information of China (English)

    ZHANG Ping; FAN Wen-Bin; ZHAO Xian-Geng

    2001-01-01

    We study the transmission dynamics of a driven two-level system dissipated by the two leads. Using the nonequilibrium Green function, we derive an analytical transmission formula for an electron incident from the left lead,through the double quantum dots, to the right lead. The Landauer-type conductance and current are also given.A discussion of the internal tunnelling dynamics reveals crucial effects of the localization and delocalization on the transport of the system.

  12. Low pressure electrospray ionization system and process for effective transmission of ions

    Science.gov (United States)

    Tang, Keqi; Page, Jason S.; Kelly, Ryan T.; Smith, Richard D.

    2010-03-02

    A system and method are disclosed that provide up to complete transmission of ions between coupled stages with low effective ion losses. A novel "interfaceless" electrospray ionization system is further described that operates the electrospray at a reduced pressure such that standard electrospray sample solutions can be directly sprayed into an electrodynamic ion funnel which provides ion focusing and transmission of ions into a mass analyzer.

  13. Simulation on Dual-stream Transmission System of Unmanned Tracked Armored Vehicle Using ADAMS

    Directory of Open Access Journals (Sweden)

    Sun Wei

    2015-01-01

    Full Text Available For the dual-stream transmission system of unmanned tracked armored vehicle, simulation analysis is carried out. Using SolidWorks to establish three-dimensional model of its chassis, the result of the simulation is processed in AdAMS/Solver. The simulation results are showed in lines. Comparative analysis for each simulation lines is conducted, and it verifies the feasibility of the dual-stream transmission system.

  14. Massive WDM and TDM Soliton Transmission Systems : a ROSC Symposium

    CERN Document Server

    2002-01-01

    This book summarizes the proceedings of the invited talks presented at the “International Symposium on Massive TDM and WDM Optical Soliton Tra- mission Systems” held in Kyoto during November 9–12, 1999. The symposium is the third of the series organized by Research Group for Optical Soliton C- munications (ROSC) chaired by Akira Hasegawa. The research group, ROSC, was established in Japan in April 1995 with a support of the Japanese Ministry of Post and Telecommunications to promote collaboration and information - change among communication service companies, communication industries and academic circles in the theory and application of optical solitons. The symposium attracted enthusiastic response from worldwide researchers in the field of soliton based communications and intensive discussions were made. In the symposium held in 1997, new concept of soliton transmission based on dispersion management of optical fibers were presented. This new soliton is now called the dispersion managed soliton. The p...

  15. Design of security scheme of the radiotherapy planning administration system based on the hospital information system

    International Nuclear Information System (INIS)

    Objective: To design a security scheme of radiotherapy planning administration system. Methods: Power Builder 9i language was used to program the system through the model of client-server machine. Oracle 9i was used as the database server. Results In this system, user registration management, user login management, application-level functions of control, database access control, and audit trail were designed to provide system security. Conclusions: As a prototype for the security analysis and protection of this scheme provides security of the system, application system, important data and message, which ensures the system work normally. (authors)

  16. FORMING MANAGEMENT IMPACTS IN AVIATION COMPANIES ECONOMIC DEVELOPMENT ADMINISTRATION SYSTEM

    Directory of Open Access Journals (Sweden)

    Victoria Prokhorova

    2016-06-01

    Full Text Available Purpose: Oriented reflective approach to management involves restructuring of goal, ideal and pragmatic, creating a program of action, organizing, correcting, control the definition of the new strategy. This process is only possible with multidimensional analysis and reflection of all the administrative restructuring process and its elements in determining and planning activities, creating conditions of restructuring, predicting outcomes and consequences of making a choice of ways to solve problems means to achieve the goal of information called ' bonds with participants restructuring process and correction flow management process based on continuous reflection. Methods: Development of the system of economic development now requires the use of mechanisms for continuous monitoring of internal and external environment to identify factors that threaten businesses. Rest of this is possible through the use of diagnostic tests: static analysis, expert diagnosis, linear and dynamic programming. Results: Built as part of the study economic and mathematical models can determine the status and level of economic development potential of aerospace companies that were investigated, confirming the need for action to manage economic development. To develop the mechanism of competition in the aircraft building sector must: implementation in practice of management motivation mechanisms to ensure the appropriate level of interest in the functioning of airlines on the basis of private property; formation of economic market institutions in the field of aircraft construction, affecting the creation of a competitive environment. Discussion: Stipulates that in difficult economic crisis positive results can be achieved managers who are constantly looking for original approaches to inclusion in the development process by aligning internal external opportunities generated by market. It is concluded that aviation business management in times of economic instability or

  17. The emergence of global administrative systems: the case of sport.

    Directory of Open Access Journals (Sweden)

    L. Casini

    2015-04-01

    Full Text Available The “global” dimension of sport is, in the first instance, regulatory, and it embraces the whole complex of norms produced and implemented by regulatory sporting regimes at the international and domestic levels. These rules include not only private norms set by the International Olympic Committee (IOC and by International Federations (IFs but also “hybrid” public-private norms approved by the World Anti-Doping Agency (WADA and international law (such as the UNESCO Convention Against Doping in Sport. Sports law, therefore, is highly heterogeneous, and, above all, it is not simply transnational, but actually “global”. This law represents an autonomous global legal system, which displays distinctive features such as the presence of some separation of powers (in particular quasi-judicial, with the strategic role played by the Court of Arbitration for Sport and the development of relevant procedural principles (e.g. fairness and due process; and these principles operate both in rulemaking procedures (e.g. the adoption of the WADA Code and in adjudicatory ones (e.g. for disciplinary measures. Finally, this global legal system is made up with several international regulatory regimes, both private – such as the Olympic movement – and hybrid public and private – such as the world anti-doping regime. The paper will deal in particular with this latter issue. The analysis will focus on the global administrative dimensions of sports regimes, together with their inter-institutional relationships and its legal implications for the public and private interaction.

  18. Combination of AC Transmission Expansion Planning and Reactive Power Planning in the restructured power system

    International Nuclear Information System (INIS)

    Highlights: ► To overcome the disadvantages of DC model in Transmission Expansion Planning, AC model should be used. ► The Transmission Expansion Planning associated with Reactive Power Planning results in fewer new transmission lines. ► Electricity market concepts should be considered in Transmission Expansion Planning problem. ► Reliability aspects should be considered in Transmission Expansion Planning problem. ► Particle Swarm Optimization is a suitable optimization method to solve Transmission Expansion Planning problem. - Abstract: Transmission Expansion Planning (TEP) is an important issue in power system studies. It involves decisions on location and number of new transmission lines. Before deregulation of the power system, the goal of TEP problem was investment cost minimization. But in the restructured power system, nodal prices, congestion management, congestion surplus and so on, have been considered too. In this paper, an AC model of TEP problem (AC-TEP) associated with Reactive Power Planning (RPP) is presented. The goals of the proposed planning problem are to minimize investment cost and maximize social benefit at the same time. In the proposed planning problem, in order to improve the reliability of the system the Expected Energy Not Supplied (EENS) index of the system is limited by a constraint. For this purpose, Monte Carlo simulation method is used to determine the EENS. Particle Swarm Optimization (PSO) method is used to solve the proposed planning problem which is a nonlinear mixed integer optimization problem. Simulation results on Garver and RTS systems verify the effectiveness of the proposed planning problem for reduction of the total investment cost, EENS index and also increasing social welfare of the system.

  19. No apparent reduction in schistosome burden or genetic diversity following four years of school-based mass drug administration in mwea, central kenya, a heavy transmission area.

    Directory of Open Access Journals (Sweden)

    Agola E Lelo

    2014-10-01

    Full Text Available Schistosomiasis is a debilitating neglected tropical disease that infects over 200 million people worldwide. To combat this disease, in 2012, the World Health Organization announced a goal of reducing and eliminating transmission of schistosomes. Current control focuses primarily on mass drug administration (MDA. Therefore, we monitored transmission of Schistosoma mansoni via fecal egg counts and genetic markers in a typical school based MDA setting to ascertain the actual impacts of MDA on the targeted schistosome population.For 4 years, we followed 67 children enrolled in a MDA program in Kenya. Infection status and egg counts were measured each year prior to treatment. For 15 of these children, for which there was no evidence of acquired resistance, meaning they became re-infected following each treatment, we collected microsatellite genotype data from schistosomes passed in fecal samples as a representation of the force of transmission between drug treatments. We genotyped a total of 4938 parasites from these children, with an average of 329.2 parasites per child for the entire study, and an average of 82.3 parasites per child per annual examination. We compared prevalence, egg counts, and genetic measures including allelic richness, gene diversity (expected heterozygosity, adult worm burdens and effective number of breeders among time points to search for evidence for a change in transmission or schistosome populations during the MDA program.We found no evidence of reduced transmission or schistosome population decline over the course of the program. Although prevalence declined in the 67 children as it did in the overall program, reinfection rates were high, and for the 15 children studied in detail, schistosome egg counts and estimated adult worm burdens did not decline between years 1 and 4, and genetic diversity increased over the course of drug treatment.School based control programs undoubtedly improve the health of individuals

  20. [Study on transmission efficiency of interference system in spatially modulated Fourier transform spectrometer].

    Science.gov (United States)

    Lü, Jin-Guang; Liang, Jing-Qiu; Liang, Zhong-Zhu; Qin, Yu-Xin; Tian, Chao

    2013-03-01

    The reflection of the optic system surface and the absorption of the infrared material could reduce the transmission of the incident light in spatially modulated Fourier transform infrared spectrometer. Through the calculation of the transmission function of the interference system and the simulation of the interferogram image and recovered spectrum affected by transmission function, it was indicated that the contrast of the interferogram image declined and the spectral line intensity weakened. The theoretical analysis shows that the contrast of the interferogram image was related to the intensity reflectance of the anti-reflection film, and the attenuation of the spectrum was determined by transmission efficiency concerned with intensity reflectance R1 of the anti-reflection film, intensity reflectance R2 of the beam splitter film, and the absorption coefficient. By means of the analysis and argumentation, the absorption of the material could be ignored in our investigative wave band. So the transmission efficiency was determined only by R1 and R2. Then taking the transmission efficiency as the design target, according to the transmission required by system, the tolerance of the R1 and R2 could be gained.

  1. Cost estimation of HVDC transmission system of Bangka’s NPP candidates

    International Nuclear Information System (INIS)

    Regarding nuclear power plant development in Bangka Island, it can be estimated that produced power will be oversupply for the Bangka Island and needs to transmit to Sumatra or Java Island. The distance between the regions or islands causing considerable loss of power in transmission by alternating current, and a wide range of technical and economical issues. The objective of this paper addresses to economics analysis of direct current transmission system to overcome those technical problem. Direct current transmission has a stable characteristic, so that the power delivery from Bangka to Sumatra or Java in a large scale efficiently and reliably can be done. HVDC system costs depend on the power capacity applied to the system and length of the transmission line in addition to other variables that may be different

  2. Analysis of Interline Power Flow Controller (IPFC Location in Power Transmission Systems

    Directory of Open Access Journals (Sweden)

    Amir Kahyaei

    2011-07-01

    Full Text Available The Interline Power Flow Controller (IPFC is one of the latest generation Flexible AC Transmission Systems (FACTS controller used to control power flows of multiple transmission lines. The aim of this paper is investigation of the effect of location of IPFC on profile of voltage and real and reactive power flow in transmission lines in power system. This model is incorporated in Newton- Raphson (NR power flow algorithm to study the power flow control in transmission lines in which IPFC is placed. A program in MATLAB/SIMULINK has been written in order to extend conventional NR algorithm based on this model. Numerical results are carried out on a standard power system. The results without and with IPFC for various locations are compared in terms of voltages, active and reactive power flows to demonstrate the performance of the IPFC model.

  3. Cost estimation of HVDC transmission system of Bangka’s NPP candidates

    Energy Technology Data Exchange (ETDEWEB)

    Liun, Edwaren, E-mail: edwaren@batan.go.id; Suparman, E-mail: edwaren@batan.go.id [Centre for Nuclear Energy Development, National Nuclear Energy Agency of Indonesia (Indonesia)

    2014-09-30

    Regarding nuclear power plant development in Bangka Island, it can be estimated that produced power will be oversupply for the Bangka Island and needs to transmit to Sumatra or Java Island. The distance between the regions or islands causing considerable loss of power in transmission by alternating current, and a wide range of technical and economical issues. The objective of this paper addresses to economics analysis of direct current transmission system to overcome those technical problem. Direct current transmission has a stable characteristic, so that the power delivery from Bangka to Sumatra or Java in a large scale efficiently and reliably can be done. HVDC system costs depend on the power capacity applied to the system and length of the transmission line in addition to other variables that may be different.

  4. High-voltage transmission tower-line system subjected to disaster loads

    Institute of Scientific and Technical Information of China (English)

    LI Hongnan; BAI Haifeng

    2006-01-01

    The high-voltage power transmission system is an important lifeline structure. It is significant for wide researches on the features and ability of the system subjected to earthquake and environmental loads. The promising prosperity of the system has been demonstrated around the world. The corresponding advances of the system with respect to the mechanism of loading action, analytical methods, experimental research measurements, structural vibration control, fatigue damage, lifetime prediction, and design methods are comprehensively discussed herein. Finally, further research work on dynamic response characteristics of high-voltage transmission towerline system in the near future is predicted.

  5. Optimisation of Transmission Systems by use of Phase Shifting Transformers

    Energy Technology Data Exchange (ETDEWEB)

    Verboomen, J.

    2008-10-13

    In this thesis, transmission grids with PSTs (Phase Shifting Transformers) are investigated. In particular, the following goals are put forward: (a) The analysis and quantification of the impact of a PST on a meshed grid. This includes the development of models for the device; (b) The development of methods to obtain optimal coordination of several PSTs in a meshed grid. An objective function should be formulated, and an optimisation method must be adopted to solve the problem; and (c) The investigation of different strategies to use a PST. Chapter 2 gives a short overview of active power flow controlling devices. In chapter 3, a first step towards optimal PST coordination is taken. In chapter 4, metaheuristic optimisation methods are discussed. Chapter 5 introduces DC load flow approximations, leading to analytically closed equations that describe the relation between PST settings and active power flows. In chapter 6, some applications of the methods that are developed in earlier chapters are presented. Chapter 7 contains the conclusions of this thesis, as well as recommendations for future work.

  6. Investigations and system design for simultaneous energy and data transmission through inductively coupled resonances

    Science.gov (United States)

    Schmidt, C.; Lloret Fuentes, E.; Buchholz, M.

    2015-11-01

    Wireless Power Transfer (WPT) with simultaneous data transmission through coupled magnetic resonators is investigated in this paper. The development of this system is dedicated to serve as a basis for applications in the field of Ambient Assisted Living (AAL), for example tracking vital parameters remotely, charge and control sensors and so on. Due to these different scenarios we consider, it is important to have a system which is reliable under the circumstance of changing positioning of the receiving device. State of the art radio systems would be able to handle this. Nevertheless, energy harvesting from far field sources is not sufficient to power the devices additionally on mid-range distances. For this reason, coupled magnetic resonant circuits are proposed as a promising alternative, although suffering from more complex positioning dependency. Based on measurements on a simple prototype system, an equivalent circuit description is used to model the transmission system dependent on different transmission distances and impedance matching conditions. Additionally, the simulation model is used to extract system parameters such as coupling coefficients, coil resistance and self-capacitance, which cannot be calculated in a simple and reliable way. Furthermore, a mathematical channel model based on the schematic model has been built in MATLAB©. It is used to point out the problems occurring in a transmission system with variable transmission distance, especially the change of the passband's centre frequency and its bandwidth. Existing solutions dealing with this distance dependent behaviour, namely the change of the transmission frequency dependent on distance and the addition of losses to the resonators to increase the bandwidth, are considered as not inventive. First, changing the transmission frequency increases the complexity in the data transmission system and would use a disproportional total bandwidth compared to the actually available bandwidth

  7. Effect of Tooth Profile Modification on Vibration of Power Split Gear Transmission System

    Institute of Scientific and Technical Information of China (English)

    He Lin

    2016-01-01

    Based on Newton's second law, the bend⁃torsion⁃shaft coupling nonlinear dynamic model and equations of power split gear transmission system are established. According to the principle of tooth profile modification, the tooth profile modification is considered as time⁃varying gear backlash function acting along the line of action. Then the dynamic functions are solved by using Runge⁃Kutta numerical method. After analyzing the effect of tooth profile modification quantity( TPMQ) and relative tooth profile modification length( TPML) to the nonlinear dynamic characteristics of power split gear transmission, the following conclusions are drawn:①The TPMQ of a certain stage transmission affects the vibration of its own stage more significantly than the other stage, and the coupling effect between two stages can be ignored usually in the modification design;②If the first stage TPMLs are less than 0.3, the influence of the first stage TPMLs to the first stage transmission vibration is much more greatly than the influence of the second stage TPMLs to the first stage transmission vibration, or else both the first and second stage TPMLs affect the first stage transmission vibration largely. The same is true for the second stage TPMLs, and the cutoff value is 0. 2; ③The TPMQ affects the vibration of power split gear transmission system more principally than the TPML, and should be top⁃priority in the modification design.

  8. Peak Power Reduction in OFDM Systems for Multicarrier Transmission

    OpenAIRE

    Sabhyata Uppal,; Sanjay Sharma

    2013-01-01

    The transmit signals in an OFDM system can have high peak values in the time domain since many subcarrier components are added via an IFFT operation. Therefore, OFDM systems are known to have a high PAPR (Peak-to-Average Power Ratio), compared with single-carrier systems. In fact, the high PAPR is one of the most detrimental aspects in the OFDM system, as it decreases the SQNR (Signal-to-Quantization Noise Ratio) of ADC (Analog-to-Digital Converter) and DAC (Digital-to-Analog Converter) while...

  9. 78 FR 73112 - Monitoring System Conditions-Transmission Operations Reliability Standards; Interconnection...

    Science.gov (United States)

    2013-12-05

    ...); TOP-005-2a (Operational Reliability Information); TOP-006-2 (Monitoring System Conditions); TOP-007-0... Reliability Standards ``address the important reliability goal of ensuring that the transmission system is... System Operating Limits (SOLs).\\5\\ The provisions in the proposed TOP Reliability Standards that...

  10. Expedience of application of MIMO systems of digital communication for complex chaotic signal transmission

    OpenAIRE

    Vasyuta, K. S.; Zakharchenko, I. V.; Ozerov, S. V.

    2015-01-01

    The paper discusses the expediency of using MIMO digital systems for transmission of chaotic signals as a way of partial solution of electromagnetic compatibility of perspective broadband communication systems with an existing class of narrow-band radio-technical systems.

  11. Line-of-Sight MIMO for Next-Generation Microwave Transmission Systems

    Institute of Scientific and Technical Information of China (English)

    Xianwei Gong; Zhifeng Yuan; Jun Xu; Liujun Hu

    2012-01-01

    Line-of-sight MIMQ (LoS MIMO) is not applicable in scattering wireless transmission scenarios, but it may be applied in LoS microwave transmission scenarios if antenna spacing (within transmit and/or receive arrays) is suitable and there is one hop distance. LoS MIMQ can improve channel capacity and performance of a transmission system. In this paper, we discuss factors affecting channel capacity and performance in LoS MIMO. We also discuss the feasibility LoS MIMO applications.

  12. Optimal transmission strategy for spatially correlated MIMO systems with channel statistical information

    Institute of Scientific and Technical Information of China (English)

    ZHAO Zhen-shan; XU Guo-zhi

    2007-01-01

    In real multiple-input multiple-output (MIMO) systems, the perfect channel state information (CSI) may be costly or impossible to acquire. But the channel statistical information can be considered relatively stationary during long-term transmission.The statistical information can be obtained at the receiver and fed back to the transmitter and do not require frequent update. By exploiting channel mean and covariance information at the transmitter simultaneously, this paper investigates the optimal transmission strategy for spatially correlated MIMO channels. An upper bound of ergodic capacity is derived and taken as the performance criterion. Simulation results are also given to show the performance improvement of the optimal transmission strategy.

  13. Transmission Needs In A Fully Renewable Pan-European Electricity System

    DEFF Research Database (Denmark)

    Rodriguez, Rolando A.; Bruun Andresen, Gorm; Becker, Sarah;

    2012-01-01

    Based on high-resolution weather and electrical load data, the transmission needs for a fully renewable pan-European electricity system are determined. The ideal cross-border transmission capacities turn out to be a factor 10 larger than those of today. A reduction of cross-border transmission ca...... capacities lead to a non-linear increase of balancing needs. A good compromise turns out to be a capacity layout, which is a factor 5 larger than today’s one. On average each country will only be able to import / export 40% of its residual demand / renewable excess generation....

  14. Precision-analog fiber-optic transmission system

    International Nuclear Information System (INIS)

    This article describes the design, experimental development, and construction of a DC-coupled precision analog fiber optic link. Topics to be covered include overall electrical and mechanical system parameters, basic circuit organization, modulation format, optical system design, optical receiver circuit analysis, and the experimental verification of the major design parameters

  15. Kansas Communication and Instruction System through Fiber-Optic Transmission.

    Science.gov (United States)

    Kansas State Dept. of Education, Topeka.

    Schools and communities will restructure as they move into the next decade. The success of this restructuring will be dependent upon access to and sharing of quality teaching and information through an expanded communication system. One of the major two-way interactive technologies is the fiber-optic cable: a delivery system that will provide…

  16. Guidelines for transient analysis in water transmission and distribution systems

    NARCIS (Netherlands)

    Pothof, I.W.M.; Karney, B.W.

    2012-01-01

    All water systems leak, and many supply systems do so considerably, with water losses typically of approximately 20% of the water production. The IWA Water Loss Task Force aims for a significant reduction of annual water losses by drafting documents to assist practitioners and others to prevent, mon

  17. The design and analysis of channel transmission communication system of XCTD profiler

    Science.gov (United States)

    Zheng, Yu; Wang, Xiao-Rui; Jin, Xiang-Yu; Song, Guo-Min; Shang, Ying-Sheng; Li, Hong-Zhi

    2016-10-01

    In this paper, a channel transmission communication system of expendable conductivity-temperature-depth is established in accordance to the operation characteristics of the transmission line to more accurately assess the characteristics of deep-sea abandoned profiler channel. The wrapping inductance is eliminated to maximum extent through the wrapping pattern of the underwater spool and the overwater spool and the calculation of the wrapping diameter. The feasibility of the proposed channel transmission communication system is verified through theoretical analysis and practical measurement of the transmission signal error rate in the amplitude shift keying (ASK) modulation. The proposed design provides a new research method for the channel assessment of complex abandoned measuring instrument and an important experiment evidence for the rapid development of the deep-sea abandoned measuring instrument.

  18. Research on WDM optical fiber transmission system based on fiber Raman amplifier

    Institute of Scientific and Technical Information of China (English)

    Fei Xue(薛飞); Kun Qiu(邱昆); Yue Chen(陈玥)

    2003-01-01

    After wavelength division multiplexing (WDM) optical fiber transmission system based on fiber Raman amplifier (FRA) is investigated in detail, the influence of the collocation of dispersion compensation fiber (DCF), the dispersion coefficient, dispersion slope (DS), effective core area, nonlinear index, length of FRA, launch power and the bandwidth of Bessel filter on bit error rate (BER) is deduced. The influence of Rayleigh backscattering noise on optical signal noise ratio (OSNR) is also investigated, which affects the performance of long haul transmission badly. The result indicates that the broadband long haul transmission can be realized through the reasonable design of the fiber. The result is useful to the optimal design of the WDM optical fiber transmission system based on FRA.

  19. Research of data transmission security in videoconference system

    Institute of Scientific and Technical Information of China (English)

    LIU Yan-long; WANG Chun-lei; SUN Zhi-tao

    2007-01-01

    Many coal enterprises have built the videoconference systems on their LAN(Local Area Network). As the development of these enterprises, their organizations are distributed over our country and even over the world. Therefore, the videoconference systems have to run over WAN (Wide Area Network). Normally, the structure of a videoconference system is center_division including MCU (multi control unit) and participants. No QoS and security assurance are available now because all videoconference system is based on TCP/IP. Therefore, the system stability is absolutely depended on the Network.This paper discussed how to anti ARP attacking. The method discussed in this paper is based on TCP/IP.

  20. Lymphatic filariasis control in Tanzania: effect of six rounds of mass drug administration with ivermectin and albendazole on infection and transmission

    Science.gov (United States)

    2013-01-01

    Background Control of lymphatic filariasis (LF) in most countries of sub-Saharan Africa is based on annual mass drug administration (MDA) with a combination of ivermectin and albendazole, in order to interrupt transmission. We present findings from a detailed study on the effect of six rounds of MDA with this drug combination as implemented by the National Lymphatic Filariasis Elimination Programme (NLFEP) in a highly endemic rural area of north-eastern Tanzania. Methods The effect of treatment on transmission and human infection was monitored in a community- and a school-based study during an 8-year period (one pre-intervention and 7 post-intervention years) from 2003 to 2011. Results Before intervention, 24.5% of the community population had microfilariae (mf) in the blood, 53.3% had circulating filarial antigens (CFA) and 78.9% had specific antibodies to the recombinant filarial antigen Bm14. One year after the sixth MDA, these values had decreased considerably to 2.7%, 19.6% and 27.5%, respectively. During the same period, the CFA prevalence among new intakes of Standard 1 pupils in 10 primary schools decreased from 25.2% to 5.6%. In line with this, transmission by the three vectors (Anopheles gambiae, An. funestus and Culex quinquefasciatus) as determined by dissection declined sharply (overall vector infectivity rate by 99.3% and mean monthly transmission potential by 99.2% between pre-intervention and fifth post-intervention period). A major shift in vector species composition, from predominantly anopheline to almost exclusively culicine was observed over the years. This may be largely unrelated to the MDAs but may have important implications for the epidemiology of LF in the area. Conclusions Six MDAs caused considerable decrease in all the measured indices for transmission and human infection. In spite of this, indices were still relatively high in the late period of the study, and it may take a long time to reach the recommended cut-off levels for

  1. Federal Emergency Management Information System (FEMIS) system administration guide. Version 1.4

    Energy Technology Data Exchange (ETDEWEB)

    Arp, J.A.; Burnett, R.A.; Downing, T.R. [and others

    1997-11-21

    The Federal Emergency Management Information System (FEMIS) is an emergency management planning and analysis tool that was developed by the Pacific Northwest National Laboratory (PNNL) under the direction of the US Army Chemical Biological Defense Command. The FEMIS System Administration Guide defines FEMIS hardware and software requirements and gives instructions for installing the FEMIS software package. This document also contains information on the following: software installation for the FEMIS data servers, communication server, mail server, and the emergency management workstations; distribution media loading and FEMIS installation validation and troubleshooting; and system management of FEMIS users, login privileges, and usage. The system administration utilities (tools), available in the FEMIS client software, are described for user accounts and site profile. This document also describes the installation and use of system and database administration utilities that will assist in keeping the FEMIS system running in an operational environment. The FEMIS system is designed for a single Chemical Stockpile Emergency Preparedness Program (CSEPP) site that has multiple Emergency Operations Centers (EOCs). Each EOC has personal computers (PCs) that emergency planners and operations personnel use to do their jobs. These PCs are connected via a local area network (LAN) to servers that provide EOC-wide services. Each EOC is interconnected to other EOCs via telecommunications links.

  2. Bio-Authentication based Secure Transmission System using Steganography

    CERN Document Server

    Zehra, Najme; Ahuja, Somya; Bansal, Shubha

    2010-01-01

    Biometrics deals with identity verification of an individual by using certain physiological or behavioral features associated with a person. Biometric identification systems using fingerprints patterns are called AFIS (Automatic Fingerprint Identification System). In this paper a composite method for Fingerprint recognition is considered using a combination of Fast Fourier Transform (FFT) and Sobel Filters for improvement of a poor quality fingerprint image. Steganography hides messages inside other messages in such a way that an "adversary" would not even know a secret message were present. The objective of our paper is to make a bio-secure system. In this paper bio-authentication has been implemented in terms of finger print recognition and the second part of the paper is an interactive steganographic system hides the user's data by two options- creating a songs list or hiding the data in an image.

  3. 78 FR 33705 - Postdecisional Administrative Review Process for Occupancy or Use of National Forest System Lands...

    Science.gov (United States)

    2013-06-05

    ..., the Department adopted an administrative appeal rule at 36 CFR part 251, subpart C (54 FR 3362) (251... Administrative Review Process for Occupancy or Use of National Forest System Lands and Resources AGENCY: USDA... and is not part of the administrative review process under the 251 Appeal Rule. Public Involvement...

  4. Frequency Transmission Control of Local Networked Control Systems Approach

    OpenAIRE

    O. Esquivel-Flores; H. Benítez-Pérez

    2012-01-01

    The use of Network Control Systems has been successful in the industry and therefore has opened several lines ofresearch. Control systems over a communication network include two important considerations, control andscheduling. Co-design strategies are focused on maintaining adequate control performance and maximize the level ofservice. Network scheduling is the main objective to resolve because through a balanced data load is possible tomaintain control performance in a desired level. This a...

  5. SUNRA - a sustainability rating system framework for National Road Administrations

    DEFF Research Database (Denmark)

    Sowerby, Chris; Langstraat, James; Harmer, Clare;

    National Road Administrations (NRAs) across Europe strive to improve the performance of their road networks. This improvement has been underpinned by significant research in the optimisation of road planning, design, construction and maintenance, which has enhanced the understanding of the social......, environmental and economic aspects of managing a road network. Whilst there is common understanding in some aspects of sustainability there is not a common understanding of sustainability as a whole and thus how to benchmark and improve overall performance. The Sustainability: National Road Administrations...

  6. Impact of Utility-Scale Distributed Wind on Transmission-Level System Operations

    Energy Technology Data Exchange (ETDEWEB)

    Brancucci Martinez-Anido, C.; Hodge, B. M.

    2014-09-01

    This report presents a new renewable integration study that aims to assess the potential for adding distributed wind to the current power system with minimal or no upgrades to the distribution or transmission electricity systems. It investigates the impacts of integrating large amounts of utility-scale distributed wind power on bulk system operations by performing a case study on the power system of the Independent System Operator-New England (ISO-NE).

  7. The Need of Politically Descentralization in Romanian Administrative System

    Directory of Open Access Journals (Sweden)

    Simona Mina

    2011-05-01

    Full Text Available The need for decentralization of the administrative system is one of the most discussed and acclaimed topics, in the Romanian governing acts. Decentralization, however, cannot be achieved without political decentralization, a democratization process of democracy, achieved from top to bottom, in which the state supports the evolution of the civil society through partnership, by stimulating local initiative and community development. According to Anthony Giddens’ theory, which is even more relevant due to the present economic recession, it states that the civil society represents a third option (neo-liberalism and social democracy being the other two in achieving social welfare. The welfare type state concept is replaced by the welfare society concept, in which the state and the civil society work together for progress, development and mutual support. Apart from the need for a participant democracy, the objective of this present study is to analyze the stages of the present political decentralization in Romania. We intend to find explanations and solutions regarding the fragile voice of the Romanian participant political culture. What were we lacking: logistics or the collective mentality (a consequence of the emerging democracy…? What are the distinctive mechanisms for proper governing, by which we can monitor the citizens’ involvement in the process of public decision and the ongoing possibility of influencing the governmental authorities’ policies and decisions by the people, at a national level by empowering the citizens with more authority? Respecting the existing interests of the society and not only those of the dignitaries, constitutes a condition for representation, something that the Romanian democracy lacks. Monitoring the manner in which the citizens’ interests are represented by public decision, constitutes a fundamental element of proper governing. This study’s objective is to create certain logistic conditions for the

  8. Systemic administration of erythropoietin inhibits retinopathy in RCS rats.

    Directory of Open Access Journals (Sweden)

    Weiyong Shen

    Full Text Available OBJECTIVE: Royal College of Surgeons (RCS rats develop vasculopathy as photoreceptors degenerate. The aim of this study was to examine the effect of erythropoietin (EPO on retinopathy in RCS rats. METHODS: Fluorescein angiography was used to monitor retinal vascular changes over time. Changes in retinal glia and vasculature were studied by immunostaining. To study the effects of EPO on retinal pathology, EPO (5000 IU/kg was injected intraperitoneally in 14 week old normal and RCS rats twice a week for 4 weeks. Changes in the retinal vasculature, glia and microglia, photoreceptor apoptosis, differential expression of p75 neurotrophin receptor (p75NTR, pro-neurotrophin 3 (pro-NT3, tumour necrosis factor-α (TNFα, pigment epithelium derived factor (PEDF and vascular endothelial growth factor-A (VEGF-A, the production of CD34(+ cells and mobilization of CD34(+/VEGF-R2(+ cells as well as recruitment of CD34(+ cells into the retina were examined after EPO treatment. RESULTS: RCS rats developed progressive capillary dropout and subretinal neovascularization which were accompanied by retinal gliosis. Systemic administration of EPO stabilized the retinal vasculature and inhibited the development of focal vascular lesions. Further studies showed that EPO modulated retinal gliosis, attenuated photoreceptor apoptosis and p75NTR and pro-NT3 upregulation, promoted the infiltration of ramified microglia and stimulated VEGF-A expression but had little effect on TNFα and PEDF expression. EPO stimulated the production of red and white blood cells and CD34(+ cells along with effective mobilization of CD34(+/VEGF-R2(+ cells. Immunofluorescence study demonstrated that EPO enhanced the recruitment of CD34+ cells into the retina. CONCLUSIONS: Our results suggest that EPO has therapeutic potentials in treatment of neuronal and vascular pathology in retinal disease. The protective effects of EPO on photoreceptors and the retinal vasculature may involve multiple

  9. Theoretical and experimental comparison of an ultra-high-speed laser data transmission system

    Science.gov (United States)

    Tycz, M.

    1973-01-01

    The performance of a digital optical data transmission system is specified by the probability that the system erroneously decides a signal has or has not been transmitted. Two factors which induce signal fading and thereby decrease system performance are atmospheric scintillation and transmitter pointing inaccuracy. A channel simulator was developed that is capable of producing the effects of both atmospheric scintillation and the transmitter pointing problem for a neodymium-yag optical data transmission systems. Comparison of data taken from the modulated intensity of a beam having been transmitted through the channel simulator with experimental data from GEOS-B argon laser transmission through the atmosphere to a low earth-orbiting satellite indicates that the modulated signal intensity is log-normal to the degree of measured atmospheric scintillation.

  10. Transmission Congestion and Voltage Profile Management Using TCSC and TCPAR in Deregulated Power System

    Directory of Open Access Journals (Sweden)

    K.Ragini

    2014-10-01

    Full Text Available In present days all our basic needs are relates with electricity. As the population increases, the demand for electricity is also tremendously increases. In the past, the entire electricity industry is under the control of government and also monopolized. But now, the power industry in many countries is moving rapidly from regulated conventional setup to deregulated environment. The transmission congestion is one of the technical problems that particularly appear in the deregulated power system. If congestion is not managed we face the problems of electricity price improvement and security and stability problems. Congestion relief can be handled using FACTS device such as TCSC, TCPAR where transmission capability will be improved. These FACTS devices are optimally placed on transmission system using Sensitivity approach method. The proposed method is carried out on Modified IEEE-14 bus system and IEEE-24 bus system Using Power World Simulator17 software.

  11. The Effects of Crack on the Transmission Matrix of Rotor Systems

    Directory of Open Access Journals (Sweden)

    Z.K. Peng

    2011-01-01

    Full Text Available The dynamic behavior of rotor containing crack is a subject of particular interest and has been extensively investigated by researchers. The effects of crack on the natural frequencies and modal shapes and motion orbits of rotor systems have already been well explored by researchers. In the present study, the infl uence of crack on the transmission matrices of the rotor systems is investigated by using the FEM (finite element method analysis and the HBM (harmonic balance method technique. It is for the first time revealed that there are differences between the transmission matrices for the fundamental frequency components and the transmission matrices for the super-harmonic components, and the differences are mainly determined by the crack location. The results are validated by numerical experiments where the system responses of a rotor system are obtained using Runge-Kutta method. The results are of significance for the development of effective crack detection methods in practice.

  12. Report on Nova Scotia Power Company's transmission system and outages communications

    Energy Technology Data Exchange (ETDEWEB)

    Stright, R.; Cannata, M.D.Jr.; Lautenschlager, M.; Kozlosky, C.K.; Arndt, S.M. [Liberty Consulting Group, Quentin, PA (United States)

    2005-03-04

    A severe storm occurred in Nova Scotia on November 13 and 14, 2004, during which a large portion of Nova Scotia Power Inc. (NSPI) customers were without power. The storm severely damaged sections of Nova Scotia's power transmission and distribution systems. The Nova Scotia Utility and Review Board issued a request for proposals (RFP) for consultants to examine NSPI's communications as well as its transmission system operations, maintenance and planning. The Liberty Consulting Group conducted the study and reported on transmission system maintenance and structure design; transmission system planning and system design; and communications and outage response. The consultant field inspected the adequacy of design criteria and the condition of failed and remaining towers and poles in areas affected by the storm and compared results with areas not affected by the storm. The consultant also evaluated NSPI's maintenance and inspection programs, vegetation management, staffing, replacement structure inventory and lessons learned from previous weather events. The report revealed how the collapse of a small number of transmission towers resulted in such a major outage. Following the review, 74 actions were created, of which more than half are complete. tabs, figs.

  13. Asynchronous Message Transmission Technique for Latency Requirements in Time Critical Ship-borne System

    Directory of Open Access Journals (Sweden)

    N. P. Shrivastava

    2016-01-01

    Full Text Available A solution to data ageing requirements in time critical ship system like fire control system is presented. In an operational sea borne platform, navigation requirements for the onboard systems are fulfilled by ring laser gyro-based inertial navigation system. For critical systems like fire control system, navigational data must be delivered in real time without any delay. However due to delay occurring in processing of raw information and transmission of data on interface bus some latency is introduced. Algorithm for an asynchronous message transmission technique from inertial navigation system to user system to meet its latency requirements is discussed. Latency requirement is achieved by sending a separate message with the time stamp for the instance the first byte of 100 Hz attitude data is received at the processing computer of navigation system.Defence Science Journal, Vol. 66, No. 1, January 2016, pp. 26-29, DOI: http://dx.doi.org/10.14429/dsj.66.8502

  14. Development of Wireless Data Transmission System for the Monitoring in Geological Disposal of Radioactive Waste - 12063

    International Nuclear Information System (INIS)

    The authors have been developing a wireless data transmission system to monitor the performance of a geological disposal system for radioactive waste. The system's concepts, advantages, and a recent development focused on reducing transmitter size to suit narrow spaces such as bentonite buffers and boreholes. A wireless transmitter with a built-in temperature sensor and a connector for external sensors has been developed, measuring 130 mm in length and 50 mm in diameter. The capability of the transmitter was confirmed by transmission tests on the ground and in a bentonite block. (authors)

  15. Phase-modulation transmission system for quantum cryptography.

    Science.gov (United States)

    Mérolla, J M; Mazurenko, Y; Goedgebuer, J P; Porte, H; Rhodes, W T

    1999-01-15

    We describe a new method for quantum key distribution that utilizes phase modulation of sidebands of modulation by use of integrated electro-optic modulators at the transmitting and receiving modules. The system is shown to produce constructive or destructive interference with unity visibility, which should allow quantum cryptography to be carried out with high flexibility by use of conventional devices.

  16. A management strategy for the Naval administrative telephone system.

    OpenAIRE

    Edgell, Timothy L.

    1985-01-01

    Management responsibility for the Navy's administrative telephones is in transition from the Commander, Naval Facilities Engineering Command to the Commander, Naval Telecommunications Command. This shift of responsibility was precipitated by fundamental structural changes within the telecommunications industry, changes which produced a volatile market structure rife with competition. A new management strategy is required to deal with these changes. The development of a...

  17. Systemic administration of 3-bromopyruvate in treating disseminated aggressive lymphoma.

    Science.gov (United States)

    Schaefer, Niklaus G; Geschwind, Jean F; Engles, James; Buchanan, Julia W; Wahl, Richard L

    2012-01-01

    toxicity of the daily administration of 10 mg/kg 3-BrPA was a reduction in body weight. Body weight at day 0 was 17.22 g ± 0.84 g in the treatment group and 17.58 g ± 0.86 g in the control group. Body weight at day +6 was 15.02 g ± 2.04 g in the treated group and 19.4 g ± 0.63 g in the control group. 3-BrPA demonstrated a significant positive tumor response both in vitro and in vivo. This, to our knowledge, is the first report of the use of 3-BrPA in a systemic tumor model. Based on these data, 3-BrPA holds promise for treatment of systemic metastatic cancers. PMID:22153810

  18. Frequency Transmission Control of Local Networked Control Systems Approach

    Directory of Open Access Journals (Sweden)

    O. Esquivel-Flores

    2012-08-01

    Full Text Available The use of Network Control Systems has been successful in the industry and therefore has opened several lines ofresearch. Control systems over a communication network include two important considerations, control andscheduling. Co-design strategies are focused on maintaining adequate control performance and maximize the level ofservice. Network scheduling is the main objective to resolve because through a balanced data load is possible tomaintain control performance in a desired level. This article reviews a scheduling strategy based on frequencytransition modeled as a linear subsystem, this control reconfigure on line the sensors’ periods. The case of study isthe control of a prototype helicopter and by numerical simulations it shows the effect of changing the transmissionfrequency.

  19. Portable light transmission measuring system for preserved corneas

    Science.gov (United States)

    Ventura, Liliane; de Jesus, Gabriel Torres; de Oliveira, Gunter Camilo Dablas; Sousa, Sidney JF

    2005-01-01

    Background The authors have developed a small portable device for the objective measurement of the transparency of corneas stored in preservative medium, for use by eye banks in evaluation prior to transplantation. Methods The optical system consists of a white light, lenses, and pinholes that collimate the white light beams and illuminate the cornea in its preservative medium, and an optical filter (400–700 nm) that selects the range of the wavelength of interest. A sensor detects the light that passes through the cornea, and the average corneal transparency is displayed. In order to obtain only the tissue transparency, an electronic circuit was built to detect a baseline input of the preservative medium prior to the measurement of corneal transparency. The operation of the system involves three steps: adjusting the "0 %" transmittance of the instrument, determining the "100 %" transmittance of the system, and finally measuring the transparency of the preserved cornea inside the storage medium. Results Fifty selected corneas were evaluated. Each cornea was submitted to three evaluation methods: subjective classification of transparency through a slit lamp, quantification of the transmittance of light using a corneal spectrophotometer previously developed, and measurement of transparency with the portable device. Conclusion By comparing the three methods and using the expertise of eye bank trained personnel, a table for quantifying corneal transparency with the new device has been developed. The correlation factor between the corneal spectrophotometer and the new device is 0,99813, leading to a system that is able to standardize transparency measurements of preserved corneas, which is currently done subjectively. PMID:16372912

  20. Compensating for Nonlinear Effects in Coherent Detection Optical Transmission Systems

    Institute of Scientific and Technical Information of China (English)

    2012-01-01

    Fiber nonlinearity is one of the most important limiters of capacity in coherent optical communications. In this paper, we review two nonlinear compensation methods: digital backward propagation (BP) and nonlinear electrical equalizer (NLEE) based on the timedomain Volterra series. These compensation algorithms are implemented in a singlechannel 50 Gb/s coherent optical singlecarrier frequency division multiplexed (CO-SCFDM) system transmitting over 10 × 80 km of standard singlemode fiber (SSMF).

  1. Nonreciprocal transmission of neutrons through the noncoplanar magnetic system

    OpenAIRE

    Tatarskiy, D. A.; Petrenko, A. V.; S. N. VDOVICHEV; Udalov, O. G.; Nikitenko, Yu. V.; Fraerman, A. A.

    2014-01-01

    We report on observation of the time reversal symmetry breaking in unpolarized neutrons scattering experiment. Neutron transmittivity through the system consisting of two magnetic mirrors placed in an external magnetic field is measured. Time reversal symmetry holds for coplanar magnetic configuration, meaning that transmitted intensity does not change when interchanging neutron source and detector. Contrarily, for noncoplanar magnetic configuration the time reversal symmetry breaks down. In ...

  2. Probe Improvement of Inductive Sensor for Online Health Monitoring of Mechanical Transmission Systems

    DEFF Research Database (Denmark)

    Wang, Chao; Liu, Xiao; Chen, Zhe

    2015-01-01

    Metal debris in lubricating oil contains abundant information regarding the ageing and wear/damage of mechanical transmission systems. The health condition of the lubricated systems can be indicated by the concentration and size of the metal abrasive particles, which may provide very early warnings...

  3. Experimental security estimation of multimedia digital data transmission systems based on SHDSL technologies

    OpenAIRE

    Shynkarenko, I.V.; Tsopa, O. I.

    2011-01-01

    The paper presents a structure of the hardware-software complex for investigating the wiretap channels of wire segments of local communication systems. In addition, it also presents new experimental data on the estimation of hiding and noise immunity of multimedia digital data transmission systems based on SHDSL technologies.

  4. Insulator and Clerance Requirements in Overhead Line Transmission Systems without Shield Wires

    DEFF Research Database (Denmark)

    Sørensen, Thomas Kjærsgaard; Holbøll, Joachim

    2008-01-01

    This paper theoretically examines the required insulation lengths and clearances in 400 kV overhead line systems when not making use of ground wires as lightning protection. The influence of lightning strikes to the system is investigated based on dynamic transmission line simulations of a 400 kV...

  5. Data model for the collaboration between land administration systems and agricultural land parcel identification systems.

    Science.gov (United States)

    Inan, Halil Ibrahim; Sagris, Valentina; Devos, Wim; Milenov, Pavel; van Oosterom, Peter; Zevenbergen, Jaap

    2010-12-01

    The Common Agricultural Policy (CAP) of the European Union (EU) has dramatically changed after 1992, and from then on the CAP focused on the management of direct income subsidies instead of production-based subsidies. For this focus, Member States (MS) are expected to establish Integrated Administration and Control System (IACS), including a Land Parcel Identification System (LPIS) as the spatial part of IACS. Different MS have chosen different solutions for their LPIS. Currently, some MS based their IACS/LPIS on data from their Land Administration Systems (LAS), and many others use purpose built special systems for their IACS/LPIS. The issue with these different IACS/LPIS is that they do not have standardized structures; rather, each represents a unique design in each MS, both in the case of LAS based or special systems. In this study, we aim at designing a core data model for those IACS/LPIS based on LAS. For this purpose, we make use of the ongoing standardization initiatives for LAS (Land Administration Domain Model: LADM) and IACS/LPIS (LPIS Core Model: LCM). The data model we propose in this study implies the collaboration between LADM and LCM and includes some extensions. Some basic issues with the collaboration model are discussed within this study: registration of farmers, land use rights and farming limitations, geometry/topology, temporal data management etc. For further explanation of the model structure, sample instance level diagrams illustrating some typical situations are also included.

  6. A full-duplex CATV/wireless-over-fiber lightwave transmission system.

    Science.gov (United States)

    Li, Chung-Yi; Lu, Hai-Han; Ying, Cheng-Ling; Cheng, Chun-Jen; Lin, Che-Yu; Wan, Zhi-Wei; Chen, Jian-Hua

    2015-04-01

    A full-duplex CATV/wireless-over-fiber lightwave transmission system consisting of one broadband light source (BLS), two optical interleavers (ILs), one intensity modulator, and one phase modulator is proposed and experimentally demonstrated. The downstream light is optically promoted from 10Gbps/25GHz microwave (MW) data signal to 10Gbps/100GHz and 10Gbps/50GHz millimeter-wave (MMW) data signals in fiber-wireless convergence, and intensity-modulated with 50-550 MHz CATV signal. For up-link transmission, the downstream light is phase-remodulated with 10Gbps/25GHz MW data signal in fiber-wireless convergence. Over a 40-km single-mode fiber (SMF) and a 10-m radio frequency (RF) wireless transport, bit error rate (BER), carrier-to-noise ratio (CNR), composite second-order (CSO), and composite triple-beat (CTB) are observed to perform well in such full-duplex CATV/wireless-over-fiber lightwave transmission systems. This full-duplex 100-GHz/50-GHz/25-GHz/550-MHz lightwave transmission system is an attractive alternative. This transmission system not only presents its advancement in the integration of fiber backbone and CATV/wireless feeder networks, but also it provides the advantages of a communication channel for higher data rates and bandwidth.

  7. Power line maintenance information system using low-power radio data transmission. Shodenryoku musen denso wo riyoshita sodensen hoshu joho system

    Energy Technology Data Exchange (ETDEWEB)

    Kanemaru, K.; Matsubara, R.; Kaito, J.; Toyota, S. (Hitachi Cable, Ltd., Tokyo (Japan))

    1994-05-20

    Currently in the major power transmission line, a composite fiber optic overhead ground wire (OPGW) is installed, and it is being made the best use as an information transmission line. When the various maintenance informations on the transmission lines can be collected and transmitted by utilizing this OPGW, there will be the benefits that an effective system for the maintenance work of the transmission lines can be constructed, the informations, which could not be obtained by a conventional patrol and tour inspection so far, could be all the time acquired highly accurately and more rapidly. In this report by considering a use of the radio transmission together with OPGW transmission, in order to solve the constraints on an information transmission in a power transmission line maintenance system by utilizing OPGW, the concrete radio transmission systems were proposed about each of interpolation method of the sensor signal transmission method and the OPGW data transmission system. Especially as for the sensor signal system, it was shown that, as a result of the quantitative investigation of a transmission efficiency taking account of the hidden terminal problems, an interpolating data transmission system through a low-power radio combined the slotted transmission timing with the carrier sensed multiple access (CSMA) system was superior. 8 refs., 7 figs., 6 tabs.

  8. HVDC transmission power conversion applications in power systems

    CERN Document Server

    Kim, Chan-Ki; Jang, Gil-Soo; Lim, Seong-Joo; Lee, Seok-Jin

    2009-01-01

    HVDC is a critical solution to several major problems encountered when trying to maintain systemic links and quality in large-scale renewable energy environments. HDVC can resolve a number of issues, including voltage stability of AC power networks, reducing fault current, and optimal management of electric power, ensuring the technology will play an increasingly important role in the electric power industry. To address the pressing need for an up-to-date and comprehensive treatment of the subject, Kim, Sood, Jang, Lim and Lee have collaborated to produce this key text and reference.  Combin

  9. Reliability worth applied to transmission expansion planning based on ant colony system

    Energy Technology Data Exchange (ETDEWEB)

    Leite da Silva, Armando M.; Rezende, Leandro S. [Institute of Electric Systems and Energy, Federal University of Itajuba, UNIFEI (Brazil); da Fonseca Manso, Luiz A.; de Resende, Leonidas C. [Department of Electrical Engineering, Federal University of Sao Joao del Rei, UFSJ (Brazil)

    2010-12-15

    This paper proposes a new methodology to solve transmission expansion planning (TEP) problems in power system, based on the metaheuristic ant colony optimisation (ACO). The TEP problem includes the search for the least cost solution, bearing in mind investment cost and reliability worth. Reliability worth is considered through the assessment of the interruption costs represented by the index LOLC - loss of load cost. The focus of this work is the development of a tool for the multi-stage planning of transmission systems and how reliability aspects can influence on the decision-making process. The applications of the proposed methodology are illustrated through case studies carried out using a test system and a real sub-transmission network. (author)

  10. A Case Study Of Turkish Transmission System For VoltageDips

    DEFF Research Database (Denmark)

    Inan, E.; Alboyaci, B.; Bak, Claus Leth

    2009-01-01

    Power quality problems usually appear in the form of voltage sags, transients and harmonics. From these three broad categories of power quality problems, voltage dips account the most disturbances experienced by industrial customers. Voltage dips generally refer to instantaneous short......-duration voltage variations. The aim of this paper is to have an idea about voltage dip performance of Turkey Transmission System. Turkey's transmission system has 21 regions. For simulations, 2nd region, which includes Istanbul city's area is heavy loaded, is selected. For purposes of early warning and later...... analysis of voltage dip performance of the whole transmission system, is used to compare with results constructed fault statics from SIMPOW DIPS analysis program real data. SIMPOW DIPS software enables to calculate dip frequency for all busses and lines....

  11. Optogenetic stimulation of VTA dopamine neurons reveals that tonic but not phasic patterns of dopamine transmission reduce ethanol self-administration

    Directory of Open Access Journals (Sweden)

    Caroline E Bass

    2013-11-01

    Full Text Available There is compelling evidence that acute ethanol exposure stimulates ventral tegmental area (VTA dopamine cell activity and that VTA-dependent dopamine release in terminal fields within the nucleus accumbens plays an integral role in the regulation of ethanol drinking behaviors. Unfortunately, due to technical limitations, the specific temporal dynamics linking VTA dopamine cell activation and ethanol self-administration are not known. In fact, establishing a causal link between specific patterns of dopamine transmission and ethanol drinking behaviors has proven elusive. Here, we sought to address these gaps in our knowledge using a newly developed viral-mediated gene delivery strategy to selectively express Channelrhodopsin-2 (ChR2 on dopamine cells in the VTA of wild-type rats. We then used this approach to precisely control VTA dopamine transmission during voluntary ethanol drinking sessions. The results confirmed that ChR2 was selectively expressed on VTA dopamine cells and delivery of blue light pulses to the VTA induced dopamine release in accumbal terminal fields with very high temporal and spatial precision. Brief high frequency VTA stimulation induced phasic patterns of dopamine release in the nucleus accumbens. Lower frequency stimulation, applied for longer periods mimicked tonic increases in accumbal dopamine. Notably, using this optogenetic approach in rats engaged in an intermittent ethanol drinking procedure, we found that tonic, but not phasic, stimulation of VTA dopamine cells selectively attenuated ethanol drinking behaviors. Collectively, these data demonstrate the effectiveness of a novel viral targeting strategy that can be used to restrict opsin expression to dopamine cells in standard outbred animals and provide the first causal evidence demonstrating that tonic activation of VTA dopamine neurons selectively decreases ethanol self-administration behaviors.

  12. Optogenetic stimulation of VTA dopamine neurons reveals that tonic but not phasic patterns of dopamine transmission reduce ethanol self-administration.

    Science.gov (United States)

    Bass, Caroline E; Grinevich, Valentina P; Gioia, Dominic; Day-Brown, Jonathan D; Bonin, Keith D; Stuber, Garret D; Weiner, Jeff L; Budygin, Evgeny A

    2013-01-01

    There is compelling evidence that acute ethanol exposure stimulates ventral tegmental area (VTA) dopamine cell activity and that VTA-dependent dopamine release in terminal fields within the nucleus accumbens plays an integral role in the regulation of ethanol drinking behaviors. Unfortunately, due to technical limitations, the specific temporal dynamics linking VTA dopamine cell activation and ethanol self-administration are not known. In fact, establishing a causal link between specific patterns of dopamine transmission and ethanol drinking behaviors has proven elusive. Here, we sought to address these gaps in our knowledge using a newly developed viral-mediated gene delivery strategy to selectively express Channelrhodopsin-2 (ChR2) on dopamine cells in the VTA of wild-type rats. We then used this approach to precisely control VTA dopamine transmission during voluntary ethanol drinking sessions. The results confirmed that ChR2 was selectively expressed on VTA dopamine cells and delivery of blue light pulses to the VTA induced dopamine release in accumbal terminal fields with very high temporal and spatial precision. Brief high frequency VTA stimulation induced phasic patterns of dopamine release in the nucleus accumbens. Lower frequency stimulation, applied for longer periods mimicked tonic increases in accumbal dopamine. Notably, using this optogenetic approach in rats engaged in an intermittent ethanol drinking procedure, we found that tonic, but not phasic, stimulation of VTA dopamine cells selectively attenuated ethanol drinking behaviors. Collectively, these data demonstrate the effectiveness of a novel viral targeting strategy that can be used to restrict opsin expression to dopamine cells in standard outbred animals and provide the first causal evidence demonstrating that tonic activation of VTA dopamine neurons selectively decreases ethanol self-administration behaviors.

  13. Stability analysis of transmission system with high penetration of distributed generation

    OpenAIRE

    M.Reza

    2006-01-01

    Nowadays, interest in generating electricity using decentralized generators of relatively small scale ('distributed generation', DG) is increasing. This work deals with the impact of implementing DG on the transmission system transient stability, with the emphasis on a potential transition from a 'vertical power system' to a 'horizontal power system. A problem in power systems is maintaining synchronous operation of all (centralized) synchronous machines. This stability problem associated is ...

  14. An analysis of reform in administrative system of Chinese higher education

    Institute of Scientific and Technical Information of China (English)

    Hu Jian-hua

    2006-01-01

    After the founding of the People's Republic of China,the administrative system of higher education then was characterized as"centra lized","Tiao and Kuai"were segmented (some higher education institutions were directly administered by provincial govemments,and some were affiliated to the relative administrative departments of the state) and higher education institutions (HEIs) were government-run.The reform in the administrative system of higher education launched in the 1980s broke down the segmentation of"Tiao and Kuai",and changed it into a new administrative system emphasizing the role of the provincial governments ("Kuai-oriented mode").Thus,HEIs gained more autonomy and tremendous changes have taken place in the relation between HEIs and the government.However,weakening the government's administrative control over HEIs and readjusting government-HEIs relations are still the main concerns in reforming the administrative system of Chinese higher education.

  15. Ethosomes as delivery system for transdermal administration of vinpocetine.

    Science.gov (United States)

    Mao, Yan-Ting; Hua, Hai-Ying; Zhang, Xiang-Guo; Zhu, Dong-Xue; Li, Feng; Gui, Zhen-Hua; Zhao, Yong-Xing

    2013-05-01

    The purpose of the present study was to develop a novel transdermal vinpocetine patch containing a stable formulation and with good entrapment efficiency, and percutaneous absorption which via ethosome. Ethosome was found to be a more efficient delivery carrier with high encapsulation capacities (79.5% +/- 1.8%) and nanometric size (180.7 +/- 1.5 nm). In vitro percutaneous permeation experiments demonstrated that the permeation of vinpocetine through abdominal skin of Sprague Dawley was significantly increased when ethosome was used. The vinpocetine transdermal fluxes from ethosome gel (3.56 +/- 0.13 microg/cm2/h) were 6.72 and 3.10 times higher than that of vinpocetine gel solution and vinpocetine aueous solution, respectively. Furthermore, the AUC(0 --> infinity), and eliminiation half-life by the transdermal administration were significantly higher than those by the intragastric administration (P ethosome is a promising vesicular carrier for enhancing percutaneous absorption of vinpocetine. PMID:23802438

  16. Ethosomes as delivery system for transdermal administration of vinpocetine.

    Science.gov (United States)

    Mao, Yan-Ting; Hua, Hai-Ying; Zhang, Xiang-Guo; Zhu, Dong-Xue; Li, Feng; Gui, Zhen-Hua; Zhao, Yong-Xing

    2013-05-01

    The purpose of the present study was to develop a novel transdermal vinpocetine patch containing a stable formulation and with good entrapment efficiency, and percutaneous absorption which via ethosome. Ethosome was found to be a more efficient delivery carrier with high encapsulation capacities (79.5% +/- 1.8%) and nanometric size (180.7 +/- 1.5 nm). In vitro percutaneous permeation experiments demonstrated that the permeation of vinpocetine through abdominal skin of Sprague Dawley was significantly increased when ethosome was used. The vinpocetine transdermal fluxes from ethosome gel (3.56 +/- 0.13 microg/cm2/h) were 6.72 and 3.10 times higher than that of vinpocetine gel solution and vinpocetine aueous solution, respectively. Furthermore, the AUC(0 --> infinity), and eliminiation half-life by the transdermal administration were significantly higher than those by the intragastric administration (P ethosome is a promising vesicular carrier for enhancing percutaneous absorption of vinpocetine.

  17. GPS-Like Phasing Control of the Space Solar Power System Transmission Array

    Science.gov (United States)

    Psiaki, Mark L.

    2003-01-01

    The problem of phasing of the Space Solar Power System's transmission array has been addressed by developing a GPS-like radio navigation system. The goal of this system is to provide power transmission phasing control for each node of the array that causes the power signals to add constructively at the ground reception station. The phasing control system operates in a distributed manner, which makes it practical to implement. A leader node and two radio navigation beacons are used to control the power transmission phasing of multiple follower nodes. The necessary one-way communications to the follower nodes are implemented using the RF beacon signals. The phasing control system uses differential carrier phase relative navigation/timing techniques. A special feature of the system is an integer ambiguity resolution procedure that periodically resolves carrier phase cycle count ambiguities via encoding of pseudo-random number codes on the power transmission signals. The system is capable of achieving phasing accuracies on the order of 3 mm down to 0.4 mm depending on whether the radio navigation beacons operate in the L or C bands.

  18. Transient Stability of the Power System with the Exact Long Transmission Line Model

    Directory of Open Access Journals (Sweden)

    Prechanon Kumkratug

    2012-01-01

    Full Text Available Problem statement: The exact long transmission line model consists of the lump of the series resistance, reactance and shunt capacitance. With the consideration the actual long transmission line model, it causes in the difficulty of deriving the mathematical model. Approach: This study investigates the transient stability of power system with consideration the exact long transmission line model. The concept of two-port network is applied in this study. The generator, transformer and short transmission line are represented by two-port networks. With the combination principles of the series and shunt connection, the mathematical model is achieved in a much simpler way. The proposed method is tested on the sample system and compared on various cases. Results: The first swing of rotor angle curve of the faulted system without the resistance is obviously higher than that of with the resistance whereas the second swing of the faulted system without the resistance is slightly less than that of with the resistance. The critical clearing time of the system with the resistance is better than that of with resistance. Conclusion: It was found from the simulation results that the resistance of the line provides the improvement of the first swing but not for the second swing. It was found from this study that for practical long line, the resistance is very import parameters to determine the critical clearing time of the single machine infinite system whereas shunt capacitance insignificantly affects on the critical clearing time of the single machine infinite bus system.

  19. FORMING MANAGEMENT IMPACTS IN AVIATION COMPANIES ECONOMIC DEVELOPMENT ADMINISTRATION SYSTEM

    OpenAIRE

    Prokhorova, Victoria; Ukrainian Engineering and Pedagogical Academy, Kharkov, Ukraine; Bezuhla, Yuliia; Ukrainian Engineering and Pedagogical Academy, Kharkov, Ukraine

    2016-01-01

    Purpose: Oriented reflective approach to management involves restructuring of goal, ideal and pragmatic, creating a program of action, organizing, correcting, control the definition of the new strategy. This process is only possible with multidimensional analysis and reflection of all the administrative restructuring process and its elements in determining and planning activities, creating conditions of restructuring, predicting outcomes and consequences of making a choice of ways to solve pr...

  20. A Data Transmission Technique for Personal Health Systems

    Directory of Open Access Journals (Sweden)

    Jih-Fu Tu

    2013-01-01

    Full Text Available We used the modular technique to design a personal health data transmitter (PHDT that is composed of the following components: (1 the core is an embedded signal chip, (2 three kinds of transmutation modules such as USB, RF, and UART, (3 an I2C interface is used to acquire the users data, and (4 through Internet it links to the cloud server to store the personal-health data. By the experiment, we find that the modular manner is feasible, stable of functional, integral, and accurate, while it is exploited to design the PHDT. For the experiment, we present each module algorithm to find that our system is very helpful to people.

  1. Disaster Management: AN Integral Part of Science & Technology System and Land Administration-Management System

    Science.gov (United States)

    Ghawana, T.; Zlatanova, S.

    2016-06-01

    Disaster management is a multidisciplinary field, which requires a general coordination approach as well as specialist approaches. Science and Technology system of a country allows to create policies and execution of technical inputs required which provide services for the specific types of disasters management. Land administration and management agencies, as the administrative and management bodies, focus more on the coordination of designated tasks to various agencies responsible for their dedicated roles. They get help from Scientific and technical inputs & policies which require to be implemented in a professional manner. The paper provides an example of such integration from India where these two systems complement each other with their dedicated services. Delhi, the Capital of India, has such a disaster management system which has lot of technical departments of government which are mandated to provide their services as Emergency Service Functionaries. Thus, it is shown that disaster management is a job which is an integral part of Science & Technology system of a country while being implemented primarily with the help of land administration and management agencies. It is required that new policies or mandates for the Science and technology organizations of government should give a primary space to disaster management

  2. Higher order capacity statistics of multi-hop transmission systems over Rayleigh fading channels

    KAUST Repository

    Yilmaz, Ferkan

    2012-03-01

    In this paper, we present an exact analytical expression to evaluate the higher order statistics of the channel capacity for amplify and forward (AF) multihop transmission systems operating over Rayleigh fading channels. Furthermore, we present simple and efficient closed-form expression to the higher order moments of the channel capacity of dual hop transmission system with Rayleigh fading channels. In order to analyze the behavior of the higher order capacity statistics and investigate the usefulness of the mathematical analysis, some selected numerical and simulation results are presented. Our results are found to be in perfect agreement. © 2012 IEEE.

  3. 77 FR 26275 - Bonneville Power Administration; Montana-to-Washington Transmission System Upgrade Project EIS

    Science.gov (United States)

    2012-05-03

    ... fields, sensitive plants and animals, soil erosion, wetlands, floodplains, and fish and water resources... Substation in Western Montana to load centers west of the Cascades and to market hubs serving the entire Northwest power market. With this Notice of Intent, BPA is initiating the public scoping process for the...

  4. Design of high-speed data transmission system for Lanzhou heavy ion therapy accelerator

    International Nuclear Information System (INIS)

    In order to satisfy the transmission requirements of partial synchronization data and process data for the heavy ion therapy accelerator, a high-speed, error-correction, long-distance, and real-time data transmission system was proposed and achieved. It can improve the efficiency and reliability of the accelerator control and synchronization. The system optimizes the hardware configuration and layout of the traditional system. FPGA, gigabit fiber module, PXI and SDRAM are the main parts of the system. It replaces the low-speed, short-distance, and poor anti-interference of the traditional data path and the data processing chips. Through the programming in the two FPGA chips, the PXI and DMA transmission mode was used to exchange data with the server of the accelerator. The front-end of the system achieves a real-time, long-distance, and high-speed serial frame transmission with 800 MHz carrier and 100 MHz base band signal. The real-time -data like synchronous event signal, power waveform data of the heavy ion therapy accelerator can be transmitted efficiently between the server and the remote controller through the system. (authors)

  5. Nurses' Attitudes Toward the Use of the Bar-coding Medication Administration System

    NARCIS (Netherlands)

    S.D. Marini; A. Hasman; H.A.S. Huijer; H. Dimassi

    2010-01-01

    This study determines nurses' attitudes toward bar-coding medication administration system use. Some of the factors underlying the successful use of bar-coding medication administration systems that are viewed as a connotative indicator of users' attitudes were used to gather data that describe the

  6. Experiences Integrating Transmission and Distribution Simulations for DERs with the Integrated Grid Modeling System (IGMS)

    Energy Technology Data Exchange (ETDEWEB)

    Palmintier, Bryan; Hale, Elaine; Hodge, Bri-Mathias; Baker, Kyri; Hansen, Timothy M.

    2016-08-11

    This paper discusses the development of, approaches for, experiences with, and some results from a large-scale, high-performance-computer-based (HPC-based) co-simulation of electric power transmission and distribution systems using the Integrated Grid Modeling System (IGMS). IGMS was developed at the National Renewable Energy Laboratory (NREL) as a novel Independent System Operator (ISO)-to-appliance scale electric power system modeling platform that combines off-the-shelf tools to simultaneously model 100s to 1000s of distribution systems in co-simulation with detailed ISO markets, transmission power flows, and AGC-level reserve deployment. Lessons learned from the co-simulation architecture development are shared, along with a case study that explores the reactive power impacts of PV inverter voltage support on the bulk power system.

  7. Coordinated multi-point transmission technique in TDD cellular mobile system

    Institute of Scientific and Technical Information of China (English)

    Sun Shaohui; Gao Qiubin; Rakesh Tamrakar; Wang Yingmin

    2011-01-01

    Coordinated multi-point transmission/reception, CoMP, technique converts the interference signal into the useful information by controlling the interfering signals among adjacent cells. Theoretically, it is a breakthrough from the traditional interference limited non-cooperative single point transmission system, improving link reliability and enhancing the data rate. CoMP is regarded as one of the most essential and effective techniques in eliminating the inter-cell interference, boosting cell edge throughput and overall system throughput. CoMP technique has obvious advantages in TDD (time division duplexing) cellular mobile system; the necessary channel state information for CoMP can be easily obtained through channel reciprocity property in TDD system. CoMP scheme in TDD system and likely problems are analyzed in this paper, and it is shown by system simulations that the significant gain can be achieved.

  8. Fuzzy-Wavelet Based Double Line Transmission System Protection Scheme in the Presence of SVC

    Science.gov (United States)

    Goli, Ravikumar; Shaik, Abdul Gafoor; Tulasi Ram, Sankara S.

    2014-07-01

    Increasing the power transfer capability and efficient utilization of available transmission lines, improving the power system controllability and stability, power oscillation damping and voltage compensation have made strides and created Flexible AC Transmission (FACTS) devices in recent decades. Shunt FACTS devices can have adverse effects on distance protection both in steady state and transient periods. Severe under reaching is the most important problem of relay which is caused by current injection at the point of connection to the system. Current absorption of compensator leads to overreach of relay. This work presents an efficient method based on wavelet transforms, fault detection, classification and location using Fuzzy logic technique which is almost independent of fault impedance, fault distance and fault inception angle. The proposed protection scheme is found to be fast, reliable and accurate for various types of faults on transmission lines with and without Static Var compensator at different locations and with various incidence angles.

  9. A test of a 2 Tesla superconducting transmission line magnet system

    Energy Technology Data Exchange (ETDEWEB)

    Piekarz, Henryk; Carcagno, Ruben; Claypool, Brad; Foster, George W.; Hays, Steven L.; Huang, Yuenian; Kashikhin, Vladimir; Malamud, Ernest; Mazur, Peter O.; Nehring,; Oleck, Andrew; Rabehl, Roger; Schlabach, Phil; Sylvester, Cosmore; Velev, Gueorgui; Volk, James; /Fermilab; Wake, Masayoshi; /KEK, Tsukuba

    2005-09-01

    Superconducting transmission line magnet test system for an injector accelerator of a staged VLHC proton-proton colliding beam accelerator has been built and operated at Fermilab. The 1.5 m long, twin-aperture, combined function dipole magnet of 2 Tesla field is excited by a single turn 100 kA transmission line superconductor. The 100 kA dc current is generated using dc-dc switching converters powered by a bulk 240 kW supply. A pair of horizontally placed conventional leads facilitates transfer of this current to the magnet transmission line superconductor operating at liquid helium temperature. Fabrication of magnet components and magnet assembly work are described. The magnet test system and its operation are presented, and the performance is summarized.

  10. Advances in fibers and transmission line technology for long haul submarine systems

    Science.gov (United States)

    Peckham, David W.; Kim, Jinkee; Sun, Yi; Lingle, Robert L., Jr.; Levring, Ole

    2007-11-01

    The 7.1-magnitude earthquake on December 26, 2006 in the Strait of Luzon resulted in the failure of several submarine cable systems. Seven of the nine cables that pass through the strait were damaged, disrupting communications to China, Taiwan, Japan, Korea and Singapore. This recent event highlighted the dependence of international communications on submarine fiber optic transmission systems. This paper will review the evolution of optical fiber transmission line technology that has been deployed in the long haul undersea telecommunications network. It will start with a discussion of the chronological evolution of the optical fiber transmission line architecture in section one, then give more detail regarding the technology that is still being deployed today.

  11. Remote Control System of the TJ-II Microwave Transmission Lines Mirrors

    International Nuclear Information System (INIS)

    The ECRH system of the TJ-II stellarator has two gyrotrons, which deliver a maximum power of 300 kW each at a frequency of 53.2 GHz. Another 28 GHz gyrotron will be used to heat the plasma by electron Bernstein waves (EBWH). The microwave power is transmitted from the gyrotrons to the vacuum chamber by two quasi-optical transmission lines for ECRH and a corrugated waveguide for EBWH. All transmission lines have an internal movable mirror inside the vacuum chamber to focus the beam and to be able to change the launching angle. The control of the beam polarization is very important and the lines have two corrugated mirrors, which actuate as polarizers. In this report the control system of the position of these three internal mirrors and the polarizers of the EBWH transmission line is described. (Author) 20 refs

  12. Modified EESM Based Link Adaptation Algorithm for Multimedia Transmission in Multicarrier Systems

    CERN Document Server

    Sandanalakshmi, R; Manivannan, K

    2010-01-01

    The previous link adaptation algorithms on ofdm based systems use equal modulation order for all sub carrier index within a block. For multimedia transmission using ofdm as the modulation technique, unequal constellation is used within one ofdm subcarrier block, a set of subcarriers for audio and another set for video transmissions. A generic model has been shown for such a transmission and link adaptation algorithm has been proposed using EESM (Effective Exponential SNR mapping) method as basic method. Mathematical model has been derived for the channel based on bivariate Gaussian distribution in which the amplitude varies two dimensionally in the same envelope. From the Moment generating function of bivariate distribution, Probability of error has been theoretically derived. Results have been shown for BER performance of an ofdm system using unequal constellation. BER performances have been shown for different values of correlation parameter and fading figure.

  13. Impact of modulator chirp in 100 Gbps class optical discrete multi-tone transmission system

    Science.gov (United States)

    Nishihara, Masato; Tanaka, Toshiki; Takahara, Tomoo; Li, Lei; Tao, Zhenning; Rasmussen, Jens C.

    2012-12-01

    Discrete multi-tone (DMT) technology is an attractive modulation technique for short reach optical transmission system. One of the main factors that limit the performance of the 1.5-μm band DMT system is the interplay between the chromatic dispersion of the transmission fiber and the chirp characteristic of the transmitter. We experimentally measured and compared the chirp characteristics of various modulator configurations, which are lithium-niobate Mach-Zehnder modulator, directly modulated laser, and electro-absorption modulator, by the frequency discriminator method using MZ interferometer. We also measured and compared the transmission characteristics of the transmitters using above-mentioned modulators and discuss the suitable transmitter configuration for DMT technology.

  14. Adaptable System Increasing the Transmission Speed and Reliability in Packet Network by Optimizing Delay

    Directory of Open Access Journals (Sweden)

    Zbynek Kocur

    2014-01-01

    Full Text Available There is a great diversity in the transmission technologies in current data networks. Individual technologies are in most cases incompatible at physical and partially also at the link layer of the reference ISO/OSI model. Network compatibility, as the ability to transmit data, is realizable through the third layer, which is able to guarantee the operation of the different devices across their technological differences. The proposed inverse packet multiplexer addresses increase of the speed and reliability of packet transmission to the third layer, and at the same time it increases the stability of the data communication by the regulation of the delay value during the transmission. This article presents implementation of a communication system and its verification in real conditions. The conclusion compares the strengths and weaknesses of the proposed control system.

  15. 160 km all-optical OFDM transmission system with inline chromatic dispersion compensation

    Institute of Scientific and Technical Information of China (English)

    Xingyao Gu; Hongwei Chen; Minghua Chen; Shizhong Xie

    2012-01-01

    An experimental demonstration of an all-optical sampling orthogonal frequency division multiplexing (AOS-OFDM) transmission system with inline chromatic dispersion (CD) compensation is carried out to test the nonlinear influence. With five subcarriers non-return-to-zero (NRZ) modulated, the total bit rate is 50 Gb/s without polarization multiplexing. The receiver end is highly simplified with direct detection using optical Fourier transform filter. After transmission in 160-km standard single-mode fiber (SSMF) link with 130-ps/nm residual CD, an optimum input optical power for the system performance is achieved.%An experimental demonstration of an all-optical sampling orthogonal frequency division multiplexing (AOS-OFDM) transmission system with inline chromatic dispersion (CD) compensation is carried out to test the nonlinear influence.With five subcarriers non-return-to-zero (NRZ) modulated,the total bit rate is 50 Gb/s without polarization multiplexing.The receiver end is highly simplified with direct detection using optical Fourier transform filter.After transmission in 160-km standard single-mode fiber (SSMF) link with 130-ps/nm residual CD,an optimum input optical power for the system performance is achieved.Optical orthogonal frequency division multiplexing (OOFDM) method has recently drawn increasing attention as a promising technology for future high-speed optical communication systems[1,2].O-OFDM has high tolerance to chromatic dispersion (CD),polarization mode dispersion,and optical nonlinearity[3-5].

  16. Transmission Performance Analysis of Fiber Optical Parametric Amplifiers for WDM System

    Directory of Open Access Journals (Sweden)

    Xiaohong Jiang

    2009-01-01

    Full Text Available A numerical analysis is presented on the long-haul wavelength-division multiplexing (WDM transmission system employing fiber-optic parametric amplifier (FOPA cascades based on one-pump FOPA model with Raman Effect taken into account. The end-to-end equalization scheme is applied to optimize the system features in terms of proper output powers and signal-to-noise ratios (SNRs in all the channels. The numerical results show that—through adjusting the fiber spans along with the number of FOPAs as well as the channel powers at the terminals in a prescribed way—the transmission distance and system performance can be optimized. By comparing the results generated by different lengths of fiber span, we come to the optimal span length to achieve the best transmission performance. Furthermore, we make a comparison among the long-haul WDM transmission systems employing different inline amplifiers, namely, FOPA, erbium-doped fiber amplifier (EDFA, and Fiber Raman Amplifier (FRA. FOPA demonstrates its advantage over the other two in terms of system features.

  17. A method of applying two-pump system in automatic transmissions for energy conservation

    Directory of Open Access Journals (Sweden)

    Peng Dong

    2015-06-01

    Full Text Available In order to improve the hydraulic efficiency, modern automatic transmissions tend to apply electric oil pump in their hydraulic system. The electric oil pump can support the mechanical oil pump for cooling, lubrication, and maintaining the line pressure at low engine speeds. In addition, the start–stop function can be realized by means of the electric oil pump; thus, the fuel consumption can be further reduced. This article proposes a method of applying two-pump system (one electric oil pump and one mechanical oil pump in automatic transmissions based on the forward driving simulation. A mathematical model for calculating the transmission power loss is developed. The power loss transfers to heat which requires oil flow for cooling and lubrication. A leakage model is developed to calculate the leakage of the hydraulic system. In order to satisfy the flow requirement, a flow-based control strategy for the electric oil pump is developed. Simulation results of different driving cycles show that there is a best combination of the size of electric oil pump and the size of mechanical oil pump with respect to the optimal energy conservation. Besides, the two-pump system can also satisfy the requirement of the start–stop function. This research is extremely valuable for the forward design of a two-pump system in automatic transmissions with respect to energy conservation and start–stop function.

  18. Hybrid wireless-over-fiber transmission system based on multiple injection-locked FP LDs.

    Science.gov (United States)

    Li, Chung-Yi; Lu, Hai-Han; Chu, Chien-An; Ying, Cheng-Ling; Lu, Ting-Chien; Peng, Peng-Chun

    2015-07-27

    A hybrid wireless-over-fiber (WoF) transmission system based on multiple injection-locked Fabry-Perot laser diodes (FP LDs) is proposed and experimentally demonstrated. Unlike the traditional hybrid WoF transmission systems that require multiple distributed feedback (DFB) LDs to support different kinds of services, the proposed system employs multiple injection-locked FP LDs to provide different kinds of applications. Such a hybrid WoF transmission system delivers downstream intensity-modulated 20-GHz microwave (MW)/60-GHz millimeter-wave (MMW)/550-MHz cable television (CATV) signals and upstream phase-remodulated 20-GHz MW signal. Excellent bit error rate (BER), carrier-to-noise ratio (CNR), composite second-order (CSO), and composite triple-beat (CTB) are observed over a 40-km single-mode fiber (SMF) and a 4-m radio frequency (RF) wireless transport. Such a hybrid WoF transmission system has practical applications for fiber-wireless convergence to provide broadband integrated services, including telecommunication, data communication, and CATV services.

  19. Stimulated Raman Effect in Bi—driectionally Amplified and Transmission WDM Systems

    Institute of Scientific and Technical Information of China (English)

    KanZHANG; AnshiXU

    1997-01-01

    One of the nonlinear effect-SRS effect in bi-directional WDM transmission systems is studied in this paper,Analytical and numerical results are given to show the effect of SRS.Systems with uni-and bi-directional EDFAs(Erbium doped fiber amplifiers0 are also considered.And a new method to deal with SRS effect in bi-directional systems is drawn out.

  20. Temperature independent 80 Gb/s transmission system using spectral phase modulation-based TDC

    Institute of Scientific and Technical Information of China (English)

    Kangping Zhong; Tangjun Li; Nan Jia; Jian Sun; Muguang Wang

    2012-01-01

    A temperature independent 80-Gb/s 100-km transmission system is demonstrated with the use of spectral phase modulation-based tunable dispersion compensator (TDC). The principle of dispersion compensation based on spectral phase modulation as well as the relationship between spectral phase modulation function and group velocity dispersion (GVD) are theoretically studied. TDC based on spectral phase modulation is implemented. The performance of 80-Gb/s transmission system is experimentally evaluated. The nonlinear relationship between temperature and temperature-induced dispersion fluctuations is demonstrated through the asymmetric temperature-induced power penalty without dispersion compensation. With respect to the low temperature area, the temperature-induced dispersion fluctuations are smaller than those in the high temperature area. By using the proposed TDC, temperature independent 80-Gb/s transmission is successfully demonstrated under a temperature range of -20 - 60 °C with a power penalty of less than 0.8 Db.%A temperature independent 80-Gb/s 100-km transmission system is demonstrated with the use of spectral phase modulation-based tunable dispersion compensator (TDC).The principle of dispersion compensation based on spectral phase modulation as well as the relationship between spectral phase modulation function and group velocity dispersion (GVD) are theoretically studied.TDC based on spectral phase modulation is implemented.The performance of 80-Gb/s transmission system is experimentally evaluated.The nonlinear relationship between temperature and temperature-induced dispersion fluctuations is demonstrated through the asymmetric temperature-induced power penalty without dispersion compensation.With respect to the low temperature area,the temperature-induced dispersion fluctuations are smaller than those in the high temperature area.By using the proposed TDC,temperature independent 80-Gb/s transmission is successfully demonstrated under a temperature range

  1. Simulation of full duplex data transmission in ROF system using Optisystem

    Directory of Open Access Journals (Sweden)

    Sandeep Singh

    2012-06-01

    Full Text Available Wireless coverage of the end-user domain; be it outdoors or indoors, is poised to become an essential part of broadband communication networks. In order to offer integrated broadband services (combining voice, data, video, multimedia services, and new value added services, systems will need to offer higher data transmission capacities. The need for increased capacity per unit area leads to higher operating frequencies, smaller radio cells and large number of base stations (BSs, therefore cost-effective BS development is a key success to the market. For this radio over fiber (RoF technology has been proposed since it provides functionally simple BSs that are connected to a central station (CS via an optical fiber. A full-duplex data and video signal transmission over single-mode fiber (SMF based on wavelengthdivision-multiplexing (WDM and an optical add-drop multiplexing (OADM technique is proposed and simulated. Four data signals of 1.25 Gb/s /9.1-9.4GHz are transmitted over long-haul single-mode fiber for downlink transmission. For uplink transmission, four data signals, each from a BS, of 1.25 Gb/s/9.6-9.9GHz is used. Good bit error rate (BER performances were achieved for both down-link and up-link transmissions in our full-duplex RoF transport system.

  2. Lumped-element model of a tapered transmission line for impedance matching in a pulsed power system

    Science.gov (United States)

    Lee, Kun-A.; Ko, Kwang-Cheol

    2016-07-01

    In a pulsed power system, impedance matching is one of the significant factors for increasing the efficiency of the system. One of the most general methods for impedance matching is to use a tapered transmission line. Because the characteristics of a tapered transmission line are changed continuously according to its position, modeling the tapered transmission line by using lumped elements is difficult. In this study, we investigated a tapered transmission line to match the impedance of power supply to that of a load by using lumped elements especially in a pulsed power system. In modeling the tapered transmission line, we used the concept of a transmission, and we introduced an efficient modeling method. We propose a simulation model based on the investigation results. The results of the study will be useful for research on tapered transmission lines.

  3. Reprint of “Performance analysis of a model-sized superconducting DC transmission system based VSC-HVDC transmission technologies using RTDS”

    Energy Technology Data Exchange (ETDEWEB)

    Dinh, Minh-Chau, E-mail: thanchau7787@gmail.com [Changwon National University, 9 Sarim-Dong, Changwon 641-733 (Korea, Republic of); Ju, Chang-Hyeon; Kim, Sung-Kyu; Kim, Jin-Geun; Park, Minwon [Changwon National University, 9 Sarim-Dong, Changwon 641-733 (Korea, Republic of); Yu, In-Keun, E-mail: yuik@changwon.ac.kr [Changwon National University, 9 Sarim-Dong, Changwon 641-733 (Korea, Republic of)

    2013-01-15

    Highlights: ► A model-sized superconducting VSC-HVDC system was designed and fabricated. ► A real-time simulation using Real Time Digital Simulator has been performed. ► The AC loss characteristics of HTS DC power cable caused by harmonics were analyzed. ► The AC loss of the HTS DC power cable will be used as a parameter to design the cable cooling system. -- Abstract: The combination of a high temperature superconducting DC power cable and a voltage source converter based HVDC (VSC-HVDC) creates a new option for transmitting power with multiple collection and distribution points for long distance and bulk power transmissions. It offers some greater advantages compared with HVAC or conventional HVDC transmission systems, and it is well suited for the grid integration of renewable energy sources in existing distribution or transmission systems. For this reason, a superconducting DC transmission system based HVDC transmission technologies is planned to be set up in the Jeju power system, Korea. Before applying this system to a real power system on Jeju Island, system analysis should be performed through a real time test. In this paper, a model-sized superconducting VSC-HVDC system, which consists of a small model-sized VSC-HVDC connected to a 2 m YBCO HTS DC model cable, is implemented. The authors have performed the real-time simulation method that incorporates the model-sized superconducting VSC-HVDC system into the simulated Jeju power system using Real Time Digital Simulator (RTDS). The performance analysis of the superconducting VSC-HVDC systems has been verified by the proposed test platform and the results were discussed in detail.

  4. Advanced Error-Control Coding Methods Enhance Reliability of Transmission and Storage Data Systems

    Directory of Open Access Journals (Sweden)

    K. Vlcek

    2003-04-01

    Full Text Available Iterative coding systems are currently being proposed and acceptedfor many future systems as next generation wireless transmission andstorage systems. The text gives an overview of the state of the art initerative decoded FEC (Forward Error-Correction error-control systems.Such systems can typically achieve capacity to within a fraction of adB at unprecedented low complexities. Using a single code requires verylong code words, and consequently very complex coding system. One wayaround the problem of achieving very low error probabilities is turbocoding (TC application. A general model of concatenated coding systemis shown - an algorithm of turbo codes is given in this paper.

  5. Lightning location system for power transmission lines; Sodensen rakurai chiten no tanchi system

    Energy Technology Data Exchange (ETDEWEB)

    Kurihara, M. [Central Research Institute of Electric Power Industry, Tokyo (Japan)

    1996-04-01

    A novel Lightning Location System (LLS) for power transmission lines has been developed. In this system, an optical loop is constituted, wherein a light signal is reflected by an Optical Fiber Composite Ground Wire (OPGW) end, positioned opposite to the incident end, and returns to the incident end. When a lightning lands on an OPGW, the lightning current travels through the steel tower serving as the grounding route and, because the OPGW is a strand of aluminum-clad wires, produces a magnetic field in the OPGW along its longitudinal direction, which causes fluctuations in polarization simultaneously in the light signals traveling, up or down in the opposite directions, through the lightning-struck spot. When the fluctuations are observed at the receiving end, two fluctuations are detected with a certain time difference between the two, and the time difference is the required information because the time difference is equivalent to the time that is twice the time that a light signal requires to travel from the lightning-struck spot to the light-reflecting end. Accordingly, the distance from the lightning-struck spot can be calculated using the observed time difference. In actual observation in a lightning-abundant period of approximately two months and half, fluctuations in polarization were observed 51 times, and there was agreement on the order of second with the LLS lightning detecting time in 43 out of the 51. 5 refs., 3 figs.

  6. Resonant Transmission in One-Dimensional Quantum Systems with Two Parity-Invariant Point Interactions

    CERN Document Server

    Konno, Kohkichi; Takahashi, Rohta

    2016-01-01

    We discuss one-dimensional quantum systems with two parity-invariant point interactions within the framework of quantum mechanics. By investigating the conditions under which resonant transmission occurs, we show that an infinite number of resonant peaks appear only when (anti-)symmetric relations between the parameters which characterize the point interactions hold.

  7. Sound transmission through pipe systems and into plate structures in buildings. A simplified sea model

    NARCIS (Netherlands)

    Bron-van der Jagt, G.S.

    2007-01-01

    In the study presented, it has been investigated whether Statistical Energy Analysis (SEA) could be applied in a simplified way as a framework for a prediction model regarding noise due to service equipment, specifically sound transmission within (plastic wastewater) pipe systems and between these p

  8. Wide area control concepts. A pre-study. Power transmission systems

    International Nuclear Information System (INIS)

    The aim of this pre-study has been to assess technology and benefits related to new control concepts for power transmission systems. The objective is to provide basic results and information in order to prepare a main project proposal for further research activities in this area. The study has focused on recent developments in control and monitoring of power transmission systems and describes promising applications within the areas of voltage stability, angle stability (power oscillations) and system protection. Selected case studies have been performed in order to assess the technical possibility of increasing power transfer limits on critical transmission corridors in the Norwegian power system and to indicate the economic benefits involved. The case studies have mainly focused on voltage stability monitoring and power oscillation damping. One significant result from the study is related to the power export capacity on the ''Hasle'' interface, which is the main transmission corridor between Southern Norway and Sweden. The studies indicate a potential of reducing annual congestion costs on this interface in the order of 15-20 mill. NOK. It is shown that this can be achieved by increasing the export limit to 2000 MW and that this is technically possible from a security point of view through improved control and monitoring as illustrated by the case studies. The report also includes a number of proposed research activities and a layout for a main project proposal. (Author)

  9. Analysis and Simulation on Current Commutation of DC Transfer Switches in UHVDC Transmission Systems

    Institute of Scientific and Technical Information of China (English)

    PENG Chang; WEN Jialiang; MA Guohua; WANG Xiuhuan; LIU Zhigang; YU Kunshan

    2011-01-01

    The most severe working conditions of transfer switches in HVDC transmission systems identified as below: DC are For MRTB and GRTS, the most severe working condition is the failure of a single pole under operation mode. MRTB has to commutate the current from the ground return to metallic return. GRTS works in the contrary way.

  10. Multi-Terabit Long-Haul Transmission System Utilizing Distributed Raman Amplification Technologies

    Institute of Scientific and Technical Information of China (English)

    Takao; Naito; Toshiki; Tanaka

    2003-01-01

    Here we summarize multi-terabit long-haul transmission experiment and distributed Raman amplification (DRA) technologies. As well, we investigate the configuration of dispersion-managed fibers for the DRA-based system from the viewpoint of the fiber non-linear effect and required pumping power.

  11. 78 FR 5794 - Occidental Chemical Corporation v. Midwest Independent Transmission System Operator, Inc.; Notice...

    Science.gov (United States)

    2013-01-28

    ... Energy Regulatory Commission Occidental Chemical Corporation v. Midwest Independent Transmission System... (FERC or Commission); 18 CFR 385.206 and 18 CFR 385.207(a)(2) (2012), Occidental Chemical Corporation... must file a notice of intervention or motion to intervene, as appropriate. The Respondent's answer...

  12. An Initial Topology of Multi-terminal HVDC Transmission System in Europe

    DEFF Research Database (Denmark)

    Irnawan, Roni; Silva, Filipe Miguel Faria da; Bak, Claus Leth;

    2016-01-01

    In this paper, technical challenges for realizing offshore multi-terminal HVDC (MTDC) transmission system in Europe is evaluated. An offshore MTDC topology is projected by interconnecting point-to-point HVDC links with the same voltage level and technology found in south-eastern part of North Sea...

  13. Theories and technologies of electronic-electrical-mechanical integrated(EEMI)transmission system

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    @@ EEMI is one of the hot spots in cross-disciplinary research. The research in this topic was to discard the traditional mechanical gear reducer, integrate electrical motor with mechanical load, control the electrical motor by electrical power generated by microelectronics and electrical electronics; namely, form a EEMI transmission system in the mechanical equipments with low rotation rate and large rotation torque.

  14. Effect of Polarization Dependent Loss on Polarization-Multiplexed Transmission System

    Institute of Scientific and Technical Information of China (English)

    H.; C.; Ji; J.; H.; Lee; K.; J.; Park; Y.; C.; Chung

    2003-01-01

    We report on the effects of the polarization-dependent loss (PDL) on the polarization-multiplexed system. The result shows that the PDL of 0.9 dB could cause 1-dB power penalty. Unlike PMD, the effect of PDL was not dependent on the transmission speed.

  15. Stability analysis of transmission system with high penetration of distributed generation

    NARCIS (Netherlands)

    Reza, M.

    2006-01-01

    Nowadays, interest in generating electricity using decentralized generators of relatively small scale ('distributed generation', DG) is increasing. This work deals with the impact of implementing DG on the transmission system transient stability, with the emphasis on a potential transition from a 'v

  16. Transmission modulation system for mobile phone reduces battery consumption without increasing bit error rate

    NARCIS (Netherlands)

    Moretti, M.; Janssen, G.J.M.

    2000-01-01

    The transmission modulation system minimizes the wasted 'out of band' power. The digital data (1) to be transmitted is fed via a pulse response filter (2) to a mixer (4) where it modulates a carrier wave (4). The digital data is also fed via a delay circuit (5) and identical filter (6) to a second m

  17. A Seismic Transmission System for Continuous Monitoring of the Lithosphere: A Proposition

    NARCIS (Netherlands)

    Unger, R.

    2002-01-01

    The main objective of this thesis is to enhance earthquake prediction feasibility. We present the concept and the design layout of a novel seismic transmission system capable of continuously monitoring the Lithosphere for changes in Earth physics parameters governing seismic wave propagation. New-te

  18. Operation and control of a DC-grid offshore wind farm under DC transmission system faults

    DEFF Research Database (Denmark)

    Deng, Fujin; Chen, Zhe

    2013-01-01

    So far, all existing offshore wind farms have an ac collection system, and the collected power in the offshore wind farm is sent to an onshore ac grid through high-voltage ac (HVAC) or DC (HVDC) transmission lines. However, future of fshore wind farms may use dc also for power collection. Consequ...

  19. Federal Emergency Management Information System (FEMIS) System Administration Guide for FEMIS Version 1.4.6

    Energy Technology Data Exchange (ETDEWEB)

    Arp, J.A.; Bower, J.C.; Burnett, R.A.; Carter, R.J.; Downing, T.R.; Fangman, P.M.; Gerhardstein, L.H.; Homer, B.J.; Johnson, D.M.; Johnson, R.L.; Johnson, S.M.; Loveall, R.M.; Martin, T.J.; Millard, W.D.; Schulze, S.A.; Stoops, L.R.; Tzemos, S.; Wood, B.M.

    1999-06-29

    The Federal Emergency Management Information System (FEMIS) is an emergency management planning and response tool that was developed by the Pacific Northwest National Laboratory (PNNL) under the direction of the U.S. Army Chemical Biological Defense Command. The FEMIS System Administration Guide provides information necessary for the system administrator to maintain the FEMIS system. The FEMIS system is designed for a single Chemical Stockpile Emergency Preparedness Program (CSEPP) site that has multiple Emergency Operations Centers (EOCs). Each EOC has personal computers (PCs) that emergency planners and operations personnel use to do their jobs. These PCs are corrected via a local area network (LAN) to servers that provide EOC-wide services. Each EOC is interconnected to other EOCs via a Wide Area Network (WAN). Thus, FEMIS is an integrated software product that resides on client/server computer architecture. The main body of FEMIS software, referred to as the FEMIS Application Software, resides on the PC client(s) and is directly accessible to emergency management personnel. The remainder of the FEMIS software, referred to as the FEMIS Support Software, resides on the UNIX server. The Support Software provides the communication data distribution and notification functionality necessary to operate FEMIS in a networked, client/server environment.

  20. OPTIONS FOR DEVELOPMENT OF POWER TRANSMISSIONS OF MOLDAVIAN POWER SYSTEM IN PARALLEL WITH POWER SYSTEM OF UKRAINE

    Directory of Open Access Journals (Sweden)

    Kalinin L.P.

    2012-04-01

    Full Text Available The paper focuses on the analysis of possible scenarios for the future development of power transmission of Moldavian Power System in parallel operation with the Power System of Ukraine. In this case the problem is considered in the absence of synchronous connection with ENTSO-E.

  1. Longitudinal measurement of chromatic dispersion along an optical fiber transmission system with a new correction factor

    International Nuclear Information System (INIS)

    At present existence OTDR based techniques have become a standard practice for measuring chromatic dispersion distribution along an optical fiber transmission link. A constructive measurement technique has been offered in this paper, in which a four wavelength bidirectional optical time domain reflectometer (OTDR) has been used to compute the chromatic dispersion allocation beside an optical fiber transmission system. To improve the correction factor a novel formulation has been developed, which leads to an enhanced and defined measurement. The investigational outcomes obtained are in good harmony

  2. The competitive role of the transmission system in price-regulated power industries

    Energy Technology Data Exchange (ETDEWEB)

    Arellano, M. Soledad [Department of Industrial Engineering, Universidad de Chile (Chile); Serra, Pablo [Department of Economics, Universidad de Chile (Chile)

    2008-07-15

    This note shows how the transmission system can enhance competition in price-regulated power industries, thus extending earlier findings reported in the literature for deregulated industries. In the context of a two-technology, price-regulated power industry, we show that the interconnection of two markets initially supplied by a different monopoly reduces market power and raises welfare. We also show that the capacity of the transmission line plays a key role in determining whether market equilibrium lies closer to competition or monopoly. (author)

  3. MIHAELA AIRINEI,The Practice of Nepotism in the Romanian Administrative System

    OpenAIRE

    CRISTIAN MIHAI AIRINEI

    2011-01-01

    This study, which deals with the phenomenon of "nepotism" within the Romanian administrative system, intends to present the way in which this practice that has taken roots and has even acquired the status of administrative custom affects the operation of public administration and, thereby, of contemporary Romanian society. The article presents the channels whereby civil servants are recruited and how the prerogatives of their position are exercised. The article also analyzes the government's...

  4. Influence of fiber parameters on the performance of a SCM_QPSK transmission system

    Science.gov (United States)

    Togneri, Arnaldo P.; Segatto, Marcelo E. V.; Pontes, Maria José; Giraldi, Maria Thereza M. R.; Costa, J. C. W. A.

    2006-04-01

    The performance of a Subcarrier Multiplexing (SCM) optical fibre system using QPSK modulation is analysed in this paper. Our results will show that it is possible to increase the system bandwidth by controlling the input optical power. Various fibre dispersion values and subcarrier channel spacing are used in order to check the bandwidth increase proportional to the optical power. The transmission bandwidth was studied in terms of fibre dispersion and input optical power. The frequency response was measured and computed. Limitations imposed by nonlinear distortions mainly due to interplay between dispersion and self-phase modulation are verified as well. The analysis to the SCM_QPSK transmission system such as the subcarrier channel spacing, signal input power, available frequency bandwidth under the fibre specifications and system conditions operation will be explored in a specific application. It means applying this technique after setting the requirements necessary to the operation of an optical ground-wire (OPGW) already installed system. The results showed an increase of the transmission bandwidth as the optical power increases. For QPSK modulation, power penalties smaller than 1 dB were obtained only for channel spacing higher than 1.2 multiplied by the symbol rate. Experimental measurements obtained in the literature were used to validate our results. Eye opening and received eye diagrams will be evaluated in order to have a simpler receiver layout and make the entire system more reliable, since it will become more robust to error disturbance, maintenance is easier and system upgrades will be facilitated.

  5. Voltage Balancing Method on Expert System for 51-Level MMC in High Voltage Direct Current Transmission

    Directory of Open Access Journals (Sweden)

    Yong Chen

    2016-01-01

    Full Text Available The Modular Multilevel Converters (MMC have been a spotlight for the high voltage and high power transmission systems. In the VSC-HVDC (High Voltage Direct Current based on Voltage Source Converter transmission system, the energy of DC link is stored in the distributed capacitors, and the difference of capacitors in parameters and charge rates causes capacitor voltage balance which affects the safety and stability of HVDC system. A method of MMC based on the expert system for reducing the frequency of the submodules (SMs of the IGBT switching frequency is proposed. Firstly, MMC with 51 levels for HVDC is designed. Secondly, the nearest level control (NLC for 51-level MMC is introduced. Thirdly, a modified capacitor voltage balancing method based on expert system for MMC-based HVDC transmission system is proposed. Finally, a simulation platform for 51-level Modular Multilevel Converter is constructed by using MATLAB/SIMULINK. The results indicate that the strategy proposed reduces the switching frequency on the premise of keeping submodule voltage basically identical, which greatly reduces the power losses for MMC-HVDC system.

  6. Network expansion by a proactive transmission system operator: A case study

    International Nuclear Information System (INIS)

    Complex planning procedures often amplify the difference in investment time between generation and transmission. In this work we consider a transmission project in Italy and, relying on a recently proposed methodology, we compare costs and benefits of anticipating the planning process before the connection of new power plants becomes certain. Whereas the system faces lower congestion costs if the network is reinforced immediately, anticipation constitutes a sunk cost in case generation is not built. For realistic load and generation scenarios, anticipation costs, as well as differences in investment times, our results indicate that anticipation is the most efficient choice for a relatively low connection probability. Analyses of this sort are particularly relevant in light of the increasing complexity of public engagement processes and of the remarkable growth in renewable generation. - Highlights: • Delays in transmission investments can increase congestion costs. • Anticipating a transmission upgrade before a generator connects has costs/benefits. • Case study: real-life transmission project in the North of Italy. • Anticipation is the efficient choice under several scenarios

  7. Adaptive transmission schemes for MISO spectrum sharing systems: Tradeoffs and performance analysis

    KAUST Repository

    Bouida, Zied

    2014-10-01

    In this paper, we propose a number of adaptive transmission techniques in order to improve the performance of the secondary link in a spectrum sharing system. We first introduce the concept of minimum-selection maximum ratio transmission (MS-MRT) as an adaptive variation of the existing MRT (MRT) technique. While in MRT all available antennas are used for transmission, MS-MRT uses the minimum subset of antennas verifying both the interference constraint (IC) to the primary user and the bit error rate (BER) requirements. Similar to MRT, MS-MRT assumes that perfect channel state information (CSI) is available at the secondary transmitter (ST), which makes this scheme challenging from a practical point of view. To overcome this challenge, we propose another transmission technique based on orthogonal space-time block codes with transmit antenna selection (TAS). This technique uses the full-rate full-diversity Alamouti scheme in order to maximize the secondary\\'s transmission rate. The performance of these techniques is analyzed in terms of the average spectral efficiency (ASE), average number of transmit antennas, average delay, average BER, and outage performance. In order to give the motivation behind these analytical results, the tradeoffs offered by the proposed schemes are summarized and then demonstrated through several numerical examples.

  8. Reduction of PAPR and Efficient detection ordering scheme for MIMO Transmission Systems Using Power Control

    Directory of Open Access Journals (Sweden)

    V.Sreevani

    2015-12-01

    Full Text Available The technical challenges for communication engineers is the development of best performance wireless networks with negligible amount of distortions. We have to consider multipath propagation attenuation and radio spectrum inefficiency. Now a days, In MIMO (Multi Input Multi Output systems there is a huge demand for the networks with the high transmission rates and better quality of service which are having low PAPR ratio. Instead of OFDMA, filter banks are used in massive MIMO to reduce the complexity. But they are error prone to noise. This base paper discusses about PAPR reduction in MIMO systems using different precoding based OFDM systems. Mainly, minimization of multi-antenna systems by controlling the transmission power and reduction of PAPR using ZC (Zadoff-Chu matrix transform.

  9. Learning from the blackouts. Transmission system security in competitive electricity markets

    Energy Technology Data Exchange (ETDEWEB)

    none

    2005-07-01

    Electricity market reform has fundamentally changed the environment for maintaining reliable and secure power supplies. Growing inter-regional trade has placed new demands on transmission systems, creating a more integrated and dynamic network environment with new real-time challenges for reliable and secure transmission system operation. Despite these fundamental changes, system operating rules and practices remain largely unchanged. The major blackouts of 2003 and 2004 raised searching questions about the appropriateness of these arrangements. Management of system security needs to be transformed to maintain reliable electricity services in this more dynamic operating environment. These challenges raise fundamental issues for policymakers. This publication presents case studies drawn from recent large-scale blackouts in Europe, North America, and Australia. It concludes that a comprehensive, integrated policy response is required to avoid preventable large-scale blackouts in the future.

  10. Transient Stability Studies on Industrial Power Systems Interconnected to the Transmission Grid

    Directory of Open Access Journals (Sweden)

    Calderón–Guizar J.G.

    2010-10-01

    Full Text Available Aiming to ensure continuity in the electrical supply to critical processes, the electrical systems of large industrial plants, i.e. gas, and petrochemical industries usually posses local generation. Should the local generation be enough to satisfy the demand of the plant, then the interconnection with the public grid is commonly used as an important support for emergency conditions. This paper is concerned with the dynamical performance of two interconnected industrial power systems tied to the transmission system. Simulation results indicate that the frequency performance of one of the industrial plants, after the transients caused by the loss of the tie with the transmission system have died out, is greatly improved if both industrial plants remain connected after the disturbance.

  11. Multiplex transmission system for gate drive signals of inverter circuit using surface acoustic wave filters

    Science.gov (United States)

    Suzuki, Akifumi; Ueda, Kensuke; Goka, Shigeyoshi; Wada, Keiji; Kakio, Shoji

    2016-07-01

    We propose and fabricate a multiplexed transmission system based on frequency-division multiple access (FDMA) with surface acoustic wave (SAW) filters. SAW filters are suitable for use in wide-gap switching devices and multilevel inverters because of their capability to operate at high temperatures, good electrical isolation, low cost, and high reliability. Our proposed system reduces the number of electrical signal wires needed to control each switching device and eliminates the need for isolation circuits, simplifying the transmission system and gate drive circuits. We successfully controlled two switching devices with a single coaxial line and confirmed the operation of a single-phase half-bridge inverter at a supply voltage of 100 V, and the total delay time to control the switching devices was less than 2.5 µs. Our experimental results validated our proposed system.

  12. High-power microwave transmission and launching systems for fusion plasma heating systems

    International Nuclear Information System (INIS)

    Microwave power in the 30- to 300-GHz frequency range is becoming widely used for heating of plasma in present-day fusion energy magnetic confinement experiments. Microwave power is effective in ionizing plasma and heating electrons through the electron cyclotron heating (ECH) process. Since the power is absorbed in regions of the magnetic field where resonance occurs and launching antennas with narrow beam widths are possible, power deposition location can be highly controlled. This is important for maximizing the power utilization efficiency and improving plasma parameters. Development of the gyrotron oscillator tube has advanced in recent years so that a 1-MW continuous-wave, 140-GHz power source will soon be available. Gyrotron output power is typically in a circular waveguide propagating a circular electric mode (such as TE0,2) or a whispering-gallery mode (such as TE15,2), depending on frequency and power level. An alternative high-power microwave source currently under development is the free-electron laser (FEL), which may be capable of generating 2-10 MW of average power at frequencies of up to 500 GHz. The FEL has a rectangular output waveguide carrying the TE0,1 mode. Because of its higher complexity and cost, the high-average-power FEL is not yet as extensively developed as the gyrotron. In this paper, several types of operating ECH transmission systems are discussed, as well systems currently being developed. The trend in this area is toward higher power and frequency due to the improvements in plasma density and temperature possible. Every system requires a variety of components, such as mode converters, waveguide bends, launchers, and directional couplers. Some of these components are discussed here, along with ongoing work to improve their performance. 8 refs

  13. Design and analysis of the Gemini chain system in dual clutch transmission of automobile

    Science.gov (United States)

    Cheng, Yabing; Guo, Haitao; Fu, Zhenming; Wan, Nen; Li, Lei; Wang, Yang

    2015-01-01

    Chain drive system is widely used in the conditions of high-speed, overload, variable speed and load. Many studies are focused on the meshing theory and wear characteristics of chain drive system, but system design, analysis, and noise characteristics of the chain drive system are weak. System design and noise characteristic are studied for a new type Gemini chain of dual-clutch automatic transmission. Based on the meshing theory of silent chain, the design parameters of the Gemini chain system are calculated and the mathematical models and dynamic analysis models of the Gemini chain system are established. Dynamic characteristics of the Gemini chain system is simulated and the contact force of plate and pin, plate and sprockets, the chain tension forces, the transmission error and the stress of plates and pins are analyzed. According to the simulation results of the Gemini chain system, the noise experiment about system is carried out. The noise values are tested at different speed and load and spectral characteristics are analyzed. The results of simulation and experimental show that the contact forces of plate and pin, plate and sprockets are smaller than the allowable stress values, the chain tension force is less than ultimate tension and transmission error is limited in 1.2%. The noise values can meet the requirements of industrial design, and it is proved that the design and analysis method of the Gemini chain system is scientific and feasible. The design and test system is built from analysis to test of Gemini chain system. This research presented will provide a corresponding theoretical guidance for the design and dynamic characteristics and noise characteristics of chain drive system.

  14. Design and Analysis of the Gemini Chain System in Dual Clutch Transmission of Automobile

    Institute of Scientific and Technical Information of China (English)

    CHENG Yabing; GUO Haitao; FU Zhenming; WAN Nen; LI Lei; WANG Yang

    2015-01-01

    Chain drive system is widely used in the conditions of high-speed, overload, variable speed and load. Many studies are focused on the meshing theory and wear characteristics of chain drive system, but system design, analysis, and noise characteristics of the chain drive system are weak. System design and noise characteristic are studied for a new type Gemini chain of dual-clutch automatic transmission. Based on the meshing theory of silent chain, the design parameters of the Gemini chain system are calculated and the mathematical models and dynamic analysis models of the Gemini chain system are established. Dynamic characteristics of the Gemini chain system is simulated and the contact force of plate and pin, plate and sprockets, the chain tension forces, the transmission error and the stress of plates and pins are analyzed. According to the simulation results of the Gemini chain system, the noise experiment about system is carried out. The noise values are tested at different speed and load and spectral characteristics are analyzed. The results of simulation and experimental show that the contact forces of plate and pin, plate and sprockets are smaller than the allowable stress values, the chain tension force is less than ultimate tension and transmission error is limited in 1.2%. The noise values can meet the requirements of industrial design, and it is proved that the design and analysis method of the Gemini chain system is scientific and feasible. The design and test system is built from analysis to test of Gemini chain system. This research presented will provide a corresponding theoretical guidance for the design and dynamic characteristics and noise characteristics of chain drive system.

  15. ATLAS TDAQ System Administration: an overview and evolution

    CERN Document Server

    LEE, CJ; The ATLAS collaboration; BOGDANCHIKOV, A; BRASOLIN, F; CONTESCU, AC; DARLEA, GL; KOROL, A; SCANNICCHIO, DA; TWOMEY, M; VALSAN, ML

    2013-01-01

    The ATLAS Trigger and Data Acquisition (TDAQ) system is responsible for the online processing of live data streaming from the ATLAS experiment at the Large Hadron Collider (LHC) at CERN. The system processes the direct data readout from ~100 million channels on the detector through three trigger levels, selecting interesting events for analysis with a factor of 10^7 reduction on the data rate with a latency of less than a few seconds. Most of the functionality is implemented on ~3000 servers composing the online farm. Due to the critical functionality of the system a sophisticated computing environment is maintained, covering the online farm and ATLAS control rooms, as well as a number of development and testing labs. The specificity of the system required the development of dedicated applications (e.g. ConfDB, BWM) for system configuration and maintenance; in parallel other Open Source tools (Puppet and Quattor) are used to centrally configure the operating systems. The health monitoring of the TDAQ system h...

  16. Oxygen transmissibility of piggyback systems with conventional soft and silicone hydrogel contact lenses

    OpenAIRE

    López-Alemany, António; González-Méijome, José Manuel; Almeida, José B.; Parafita, Manuel A.; Refojo, Miguel F.

    2006-01-01

    To investigate the apparent oxygen transmissibility of various piggyback systems using conventional and silicone hydrogel soft contact lenses of different water content and permeability, rigid poly(methyl methacrylate), and rigid gas-permeable lenses of medium, high, and ultrahigh oxygen permeability. The aim of the study was to establish which material (rigid or hydrogel) is more representative of the resulting oxygen performance of piggyback systems. METHODS: The apparent oxygen transmissib...

  17. Power flow transmission in a coupled flexible system with active executive elements

    Institute of Scientific and Technical Information of China (English)

    HUO Rui; SHI Yin; SONG Kongjie

    2002-01-01

    Based on its prototype of machine-isolator-foundation systems, a theoretical model for dynamic coupled linear system is established, in which both the passive and active control factors are considered. Power flow is used as the cost function to evaluate the isolation effectiveness. And the transmission of vibratory power flow from a vibrating rigid body into a simply supported thin panel through passive isolators and actuators is investigated numerically. The active control strategy is summarized in the conclusion.

  18. Compact transmission system using single-sideband modulation of light for quantum cryptography.

    Science.gov (United States)

    Duraffourg, L; Merolla, J M; Goedgebuer, J P; Mazurenko, Y; Rhodes, W T

    2001-09-15

    We report a new transmission that can be used for quantum key distribution. The system uses single-sideband-modulated light in an implementation of the BB84 quantum cryptography protocol. The system is formed by two integrated unbalanced Mach-Zehnder interferometers and is based on interference between phase-modulated sidebands in the spectral domain. Experiments show that high interference visibility can be obtained.

  19. Professional performance evaluation within the Romanian administrative system

    Directory of Open Access Journals (Sweden)

    Cristina MANOLE

    2010-12-01

    Full Text Available The current economic crisis, manifested in the entire world, highlights the need for sustained involvement of the local and regional authorities in each country, in conceiving and implementing Community policies (which already exist at European level having an essential role in implementing the economic plans achievement. This view was shared by all European Union Member States, of which Romania is part, since 2007. Therefore, the economic crisis which is reflected in the Romanian society today, requires prompt and sustained intervention by the authorities in the execution of the economic recovery plan, implying the community strategies, due to sharply budgetary expenses cut, which is found in all European countries. In order to achieve this major objective, the Romanian authorities should have qualified and properly motivated personnel through an adequate remuneration, according to the training, skills, responsibilities and especially individual performance obtained at each position, as it happens in most developed countries of the European Union. In this context, this study approaches the issues related to the performance evaluation of the public sector’s employees. Considering the fact that strengthening and developing the human resources segment is a strategic goal of the Romanian administration for the period 2008 - 2013, which will lead to modernizing it and making it more efficient (at both central and local level, the personnel performance evaluation, at the organizational level represents a fundamental activity from the human resources’ management perspective.

  20. Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-140- SalemAlbany1)

    Energy Technology Data Exchange (ETDEWEB)

    Sherer, Brett M. [Bonneville Power Administration, Portland, OR (United States)

    2003-04-04

    Bonneville Power Administration (BPA) proposes to remove unwanted vegetation along the right-of- way, access roads, switch platforms, microwave beam paths, and around tower structures of the subject transmission line corridor that may impede the operation and maintenance of the identified transmission lines. BPA plans to conduct vegetation control with the goal of removing tall growing vegetation that is currently or will soon be a hazard to the transmission line. BPA’s overall goal is to have low-growing plant communities along the rights-of-way to control the development of potentially threatening vegetation.

  1. The Design of Administrative System Based On Portable Intellectual Equipment

    Institute of Scientific and Technical Information of China (English)

    Zeng,Jianhua; Chen,Haisong; Feng,Mingfa; Liang,Zhaofeng

    2005-01-01

    Regard property management of intelligentized residential area as the application background, we introduce a kind of method for the design of a management system based on portable intelligent equipments. The system is made up of intelligent terminals and personal computers. The intelligent terminals are for data collection and data storage. They communicate with personal computers through high-speed interface. The personal computers communicate with intelligent devices and carry out data analysis and data processing with VB6.0.

  2. THE INFORMATIONAL SYSTEM FOR RESOURSES ADMINISTRATION IN FISH FARMS

    Directory of Open Access Journals (Sweden)

    Adrian ZUGRAVU

    2005-01-01

    Full Text Available The informational system for aquaculture activities provide a financial planning and analysis tool.The software can also be of assistance to land-based farmers who want to more thoroughly utilizetheir water resources by developing small-scale fish farm systems to provide supplementary income.Informational model has been enhanced to produce a comprehensive software package foraquaculture feasibility modeling, financial planning, sales and harvesting planning and managementinformation tools.

  3. ATLAS TDAQ System Administration: an overview and evolution

    CERN Document Server

    LEE, CJ; The ATLAS collaboration; BOGDANCHIKOV, A; BRASOLIN, F; CONTESCU, AC; DARLEA, G-L; KOROL, A; SCANNICCHIO, DA; TWOMEY, M; VALSAN, ML

    2013-01-01

    The ATLAS Trigger and Data Acquisition (TDAQ) system is responsible for the online processing of live data streaming from the ATLAS experiment at the Large Hadron Collider (LHC) at CERN. The system processes the direct data readout from ~100 million channels on the detector through multiple trigger levels, selecting interesting events for analysis with a factor of $10^{7}$ reduction on the data rate with a latency of less than a few seconds. Most of the functionality is implemented on ~3000 servers composing the online farm. Due to the critical functionality of the system a sophisticated computing environment is maintained, covering the online farm and ATLAS control rooms, as well as a number of development and testing labs. The specificity of the system required the development of dedicated applications (e.g. ConfDB, BWM) for system configuration and maintenance; in parallel other Open Source tools (Puppet and Quattor) are used to centrally configure the operating systems. The health monitoring of the TDAQ s...

  4. Enhanced analgesic effect of morphine-nimodipine combination after intraspinal administration as compared to systemic administration in mice

    Indian Academy of Sciences (India)

    Dilip Verma; Subrata Basu Ray; Ishan Patro; Shashi Wadhwa

    2005-09-01

    Calcium plays an important role in the pathophysiology of pain. A number of studies have investigated the effect of L-type calcium channel blockers on the analgesic response of morphine. However, the results are conflicting. In the present study, the antinociceptive effect of morphine (2.5 g) and nimodipine (1 g) co-administered intraspinally in mice was observed using the tail flick test. It was compared to the analgesic effect of these drugs (morphine – 250 g subcutaneously; nimodipine – 100 g intraperitoneally) after systemic administration. Nimodipine is highly lipophilic and readily crosses the blood brain barrier. Addition of nimodipine to morphine potentiated the analgesic response of the latter when administered through the intraspinal route but not when administered through systemic route. It may be due to direct inhibitory effect of morphine and nimodipine on neurons of superficial laminae of the spinal cord after binding to -opioid receptors and L-type calcium channels respectively.

  5. Structural contradictions in control system by enterprise as function of associate administrative decisions

    OpenAIRE

    Kalyuzhna, N.; Golovkova, К.

    2013-01-01

    The key role of organizationally-functional structure improvement of management is reasonable in the increase of efficiency of preparation processes, acceptance and realization of administrative decisions on an enterprise. The algorithm of structural exposure contradictions is offered in control system by an enterprise. The morphological matrix of description of structural contradiction as functions of associate administrative decisions is formed. Sources 22.

  6. Science, Systems, and Theoretical Alternatives in Educational Administration: The Road Less Travelled

    Science.gov (United States)

    Evers, Colin W.; Lakomski, Gabriele

    2012-01-01

    Purpose: The purpose of this paper is to offer a critical reflection on ideas that have been published in the "Journal of Educational Administration" over the last 50 years that present perspectives on the nature of educational administration and its various aspects, that are alternatives to the mainstream systems-scientific view of educational…

  7. Estimation of tax administration system by taxpayers in the Ural federal district

    Directory of Open Access Journals (Sweden)

    Aleksey Sergeevich Naydyonov

    2012-12-01

    Full Text Available Significance of a government grows considerably in the context of adverse exogenous conditions and the recessionary tendencies in the world economy. One of the effective tools of a purposeful influence on the economy is tax administration. It is evident that tax administration system improvement is inseparable from development of a system of effectiveness evaluation. Analysis and systematization of theoretical and empirical investigations in the field of tax administration carried out in the course of study resulted in formulating the author’s notion of the concept of the tax administration system, which was defined as a set of forms and methods of realization of the tax mechanism by public administration intended for the encouragement of socio-economic development. Relying on the notion of tax administration system and the institutional theory it was concluded that first of all tax administration ought to be aimed at satisfying requirements of taxpayers. The extent of satisfying requirements of taxpayers was proposed to evaluate by means of designed technique of estimation of tax administration attractiveness for taxpayers. The results obtained by the application of the technique are presented in the article

  8. Discussion on the System of Administrative Counterpart's Right of Resistance in China

    Institute of Scientific and Technical Information of China (English)

    FENG Yuan; SHI Hong-ping

    2011-01-01

    The research value of the right of resistance in the administrative law has been highlighted gradually in recent years with the enhancement of legal awareness and the increase of administrative cases in our country.In this paper,based on the concept and characteristics of the administrative counterpart's right of resistance and the present situation of its development in our country,a conception of system of administrative counterpart's right of resistance is proposed with the use of the regulations concerning the right of resistance in other countries for reference.

  9. Evaluation and Verification of Channel Transmission Characteristics of Human Body for Optimizing Data Transmission Rate in Electrostatic-Coupling Intra Body Communication System: A Comparative Analysis.

    Directory of Open Access Journals (Sweden)

    Yuhwai Tseng

    Full Text Available Intra-body communication is a new wireless scheme for transmitting signals through the human body. Understanding the transmission characteristics of the human body is therefore becoming increasingly important. Electrostatic-coupling intra-body communication system in a ground-free situation that integrate electronic products that are discretely located on individuals, such as mobile phones, PDAs, wearable computers, and biomedical sensors, are of particular interest.The human body is modeled as a simplified Resistor-Capacitor network. A virtual ground between the transmitter and receiver in the system is represented by a resister-capacitor network. Value of its resistance and capacitance are determined from a system perspective. The system is characterized by using a mathematical unit step function in digital baseband transmission scheme with and without Manchester code. As a result, the signal-to-noise and to-intersymbol-interference ratios are improved by manipulating the load resistor. The data transmission rate of the system is optimized. A battery-powered transmitter and receiver are developed to validate the proposal.A ground-free system fade signal energy especially for a low-frequency signal limited system transmission rate. The system transmission rate is maximized by simply manipulating the load resistor. Experimental results demonstrate that for a load resistance of 10k-50k Ω, the high-pass 3 dB frequency of the band-pass channel is 400kHz-2MHz in the worst-case scenario. The system allows a Manchester-coded baseband signal to be transmitted at speeds of up to 20M bit per second with signal-to-noise and signal-to-intersymbol-interference ratio of more than 10 dB.The human body can function as a high speed transmission medium with a data transmission rate of 20Mbps in an electrostatic-coupling intra-body communication system. Therefore, a wideband signal can be transmitted directly through the human body with a good signal

  10. Federal Emergency Management Information System (FEMIS) system administration guide, version 1.4.5

    Energy Technology Data Exchange (ETDEWEB)

    Arp, J.A.; Burnett, R.A.; Carter, R.J. [and others

    1998-06-26

    The Federal Emergency Management Information Systems (FEMIS) is an emergency management planning and response tool that was developed by the Pacific Northwest National Laboratory (PNNL) under the direction of the US Army Chemical Biological Defense Command. The FEMIS System Administration Guide provides information necessary for the system administrator to maintain the FEMIS system. The FEMIS system is designed for a single Chemical Stockpile Emergency Preparedness Program (CSEPP) site that has multiple Emergency Operations Centers (EOCs). Each EOC has personal computers (PCs) that emergency planners and operations personnel use to do their jobs. These PCs are connected via a local area network (LAN) to servers that provide EOC-wide services. Each EOC is interconnected to other EOCs via a Wide Area Network (WAN). Thus, FEMIS is an integrated software product that resides on client/server computer architecture. The main body of FEMIS software, referred to as the FEMIS Application Software, resides on the PC client(s) and is directly accessible to emergency management personnel. The remainder of the FEMIS software, referred to as the FEMIS Support Software, resides on the UNIX server. The Support Software provides the communication, data distribution, and notification functionality necessary to operate FEMIS in a networked, client/server environment. The UNIX server provides an Oracle relational database management system (RDBMS) services, ARC/INFO GIS (optional) capabilities, and basic file management services. PNNL developed utilities that reside on the server include the Notification Service, the Command Service that executes the evacuation model, and AutoRecovery. To operate FEMIS, the Application Software must have access to a site specific FEMIS emergency management database. Data that pertains to an individual EOC`s jurisdiction is stored on the EOC`s local server. Information that needs to be accessible to all EOCs is automatically distributed by the FEMIS

  11. The design of high-speed data transmission method for a small nuclear physics DAQ system

    CERN Document Server

    Zhou, Wenxiong; Nan, Gangyang; Zhang, Jianchuan

    2013-01-01

    A large number of data need to be transmitted in high-speed between Field Programmable Gate Array (FPGA) and Advanced RISC Machines 11 micro-controller (ARM11) when we design a small data acquisition (DAQ) system for nuclear experiments. However, it is a complex problem to beat the target. In this paper, we will introduce a method which can realize the high-speed data transmission. By this way, FPGA is designed to acquire massive data from Front-end electronics (FEE) and send it to ARM11, which will transmit the data to other computer through the TCP/IP protocol. This paper mainly introduces the interface design of the high-speed transmission between FPGA and ARM11, the transmission logic of FPGA and the driver program of ARM11. The research shows that the maximal transmission speed between FPGA and ARM11 by this way can reach 50MB/s theoretically, while in nuclear physics experiment, the system can acquire data with the speed of 2.2MB/s.

  12. Improving the Transmission System Reliability for the 154kV Radial Network Operation

    Energy Technology Data Exchange (ETDEWEB)

    Choo, Jin Boo; Yoo, Myeong Ho; Yoon, Young Beum; Kim, Tae Won [Korea Electric Power Research Institute, Taejon (Korea, Republic of); Lee, Gi Won; Chung, Beom Jin; Jung, Jung Won; Park, Kyu Hyun; Lee, Myung Hee; Kim, Hyun Jong; Kim, Chae Hee [KEYIN CO., (Korea, Republic of)

    1996-12-31

    Analyzing that 154kV radial network current ed operated, we developed Automatic Power Reconfiguration System(APRS) which restore blackout area. It consists of special data acquisition system(DAU) and central monitoring system for reason of protecting currently operating power system. In addition, it communicates using optical communication network for high speed data transmission and accuracy. An Accuracy of operation and stability of the developed system is tested using Real Time Digital Simulator in 3-bus equivalent model system. In An Outage case, our developed system can restore a blackout area in three second. An ability of the restoration of a blackout was verified by simulations. For the field test, the developed system was set up at SINCHON S/S, SESOMUN S/S, SINDANG S/S and MAJANG S/S governed by Seoul Power Transmission Center. If the system reliability is proved for a one year test in real power system, application of the system will be extended to the other substations.

  13. Application of the Wireless Digital Transmission Technology in Remote ECG Monitoring System

    Institute of Scientific and Technical Information of China (English)

    Xu,Lixin; Li,Qingliang; Chen,Zhen; Qi,Xinbo; Zhang,Xincheng

    2005-01-01

    Heart disease is one of the main diseases menace human' s health. The limited monitoring ability and limited serving ability are shortcomings of the existing remote ECG (electrocardiograph) monitoring system. It is practical to bring ECG monitoring from hospital to home. A new method is introduced that the application of wireless digital transmission technology in remote ECG monitoring system. In the system, the portable ECG monitoring device to collect and transmit patient""s electrocardiogram signals and the device to transmit and receive ECG signals are designed by using the PTR2000. The method solves the remote collection and transmission of patient's electrocardiogram signals, and creates the condition of the transmitting of patient"" s electrocardiogram signals through the Broadband network.

  14. Application of the Wireless Digital Transmission Technology in Remote ECG Monitoring System

    Institute of Scientific and Technical Information of China (English)

    Xu,Lixin; Li,Qingliang; Chen,Zhen; Qi,Xinbo; Zhang,Xincheng

    2005-01-01

    Heart disease is one of the main diseases menace human's health. The limited monitoring ability and limited serving ability are shortcomings of the existing remote ECG (electrocardiograph) monitoring system. It is practical to bring ECG monitoring from hospital to home. A new method is introduced that the application of wireless digital transmission technology in remote ECG monitoring system. In the system, the portable ECG monitoring device to collect and transmit patient's electrocardiogram signals and the device to transmit and receive ECG signals are designed by using the PTR2000. The method solves the remote collection and transmission of patient s electrocardiogram signals, and creates the condition of the transmitting of patient's electrocardiogram signals through the Broadband network.

  15. Sensitivity analysis and dynamic modification of modal parameter in mechanical transmission system

    Institute of Scientific and Technical Information of China (English)

    2005-01-01

    Sensitivity analysis is one of the effective methods in the dynamic modification. The sensitivity of the modal parameters such as the natural frequencies and mode shapes in undamped free vibration of mechanical transmission system is analyzed in this paper.In particular,the sensitivities of the modal parameters to physical parameters of shaft system such as the inertia and stiffness are given.A calculation formula for dynamic modification is presented based on the analysis of modal parameter.With a mechanical transmission system as an example, the sensitivities of natural frequencies and modes shape are calculated and analyzed. Furthermore, the dynamic modification is also carried out and a good result is obtained.

  16. Accurate one-end fault location for overhead transmission lines in interconnected power systems

    Energy Technology Data Exchange (ETDEWEB)

    Eisa, Amir A.A.; Ramar, K. [Faculty of Engineering, Multimedia University, 63100 Cyberjaya (Malaysia)

    2010-06-15

    This paper presents a new one-end fault location method for overhead transmission lines embedded in a general n-bus interconnected power system. High accuracy in fault location is achieved by using both an accurate distributed parameters model for the faulted transmission line, and a two-bus Thevenin equivalent network model for the power system that accurately accounts for its interconnectivity. The method has been tested using transient fault data obtained from PSCAD/EMTDC simulations of an 11-bus interconnected power system. The results obtained indicate that the method is capable of estimating the fault distance with high accuracy for various fault conditions. They also indicate that method is sensitive to errors in the value of the local bus impedance, but is insensitive to errors in the value of the remote bus impedance. (author)

  17. Grid connection of active stall wind farms using a VSC based DC transmission system

    DEFF Research Database (Denmark)

    Iov, Florin; Sorensen, Paul; Hansen, Anca-Daniela;

    2005-01-01

    Currently, there is an increasing trend to connect large MW wind farms to the transmission system. Requirements that focus on the influence of the farms on the grid stability and power quality, and on the control capabilities of wind farms have already been established. The main trends of modern...... wind turbines/farms are clearly the variable speed operation and a grid connection through a power electronic interface, especially using doubly fed induction generators. Using power electronics the control capabilities of these wind turbines/farms are extended and thus the grid requirements are...... fulfilled. However, the traditional squirrel-cage generators based wind turbines/wind farms directly connected to the grid have less control capabilities. These wind turbines/farms cannot regulate their production and contribute to power system stability. A DC transmission system for connection of the...

  18. A new inductive sensor for online health monitoring of mechanical transmission systems

    DEFF Research Database (Denmark)

    Wang, Chao; Liu, Xiao; Chen, Zhe

    2015-01-01

    Metal debris in lubricating oil contains abundant information regarding the ageing and wear of mechanical transmission systems. The health condition of the lubricated systems can be indicated by the quantity and size of the metal particles, which may provide very early warnings of faults/ failures...... indicates the infancy failure of the system [1-2]. Inductive sensor, which transforms the quantity and size of the particles into the number and magnitude variation of pulses of coil inductance, is widely used in the online metal debris monitoring systems [1-5]....

  19. Serial Failure Diagnosis of a Transmission Line Protection Relaying System by Petri Nets

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    With the development of large-scale complicated modern power systems, the requirement for the associatedprotection scheme tends to be more stringent and its combination more complex. However, it is very difficult to figureout the factors of failure of such systems. This paper proposes a Petri net model of a transmission line protectionrelaying system, including three types of relays as well as an automatic re-closing device, and shows how to diagnoseserial failure of the system by analyzing invariant sets of the model. Furthermore, it gives four basic types of failuresequences and its execution is much more intuitive and effective than the traditional method.

  20. A role for high frequency superconducting devices in free space power transmission systems

    Science.gov (United States)

    Christian, Jose L., Jr.; Cull, Ronald C.

    1988-01-01

    Major advances in space power technology are being made in photovoltaic, solar thermal, and nuclear systems. Despite these advances, the power systems required by the energy and power intensive mission of the future will be massive due to the large collecting surfaces, large thermal management systems, and heavy shielding. Reducing this mass on board the space vehicle can result in significant benefits because of the high cost of transporting and moving mass about in space. An approach to this problem is beaming the power from a point where the massiveness of the power plant is not such a major concern. The viability of such an approach was already investigated. Efficient microwave power beam transmission at 2.45 GHz was demonstrated over short range. Higher frequencies are desired for efficient transmission over several hundred or thousand kilometers in space. Superconducting DC-RF conversion as well as RF-DC conversion offers exciting possibilities. Multivoltage power conditioning for multicavity high power RF tubes could be eliminated since only low voltages are required for Josephson junctions. Small, high efficiency receivers may be possible using the reverse Josephson effects. A conceptual receiving antenna design using superconducting devices to determine possible system operating efficiency is assessed. If realized, these preliminary assessments indicate a role for superconducting devices in millimeter and submillimeter free space power transmission systems.

  1. Modeling Interregional Transmission Congestion in the NationalEnergy Modeling System

    Energy Technology Data Exchange (ETDEWEB)

    Gumerman, Etan; Chan, Peter; Lesieutre, Bernard; Marnay, Chris; Wang, Juan

    2006-05-25

    Congestion analysis using National Energy Modeling National Energy Modeling System (NEMS) or NEMS-derivatives, such as LBNL-NEMS, is subject to significant caveats because the generation logic inherent in NEMS limits the extent to which interregional transmission can be utilized and intraregional transmission is not represented at all. The EMM is designed primarily to represent national energy markets therefore regional effects may be simplified in ways that make congestion analysis harder. Two ways in particular come to mind. First, NEMS underutilizes the capability of the traditional electric grid as it builds the dedicated and detached grid. Second, it also undervalues the costs of congestion by allowing more transmission than it should, due to its use of a transportation model rather than a transmission model. In order to evaluate benefits of reduced congestion using LBNL-NEMS, Berkeley Lab identified three possible solutions: (1) implement true simultaneous power flow, (2) always build new plants within EMM regions even to serve remote load, and (3) the dedicated and detached grid should be part of the known grid. Based on these findings, Berkeley Lab recommends the following next steps: (1) Change the build logic that always places new capacity where it is needed and allow the transmission grid to be expanded dynamically. (2) The dedicated and detached grid should be combined with the traditional grid. (3) Remove the bias towards gas fired combine cycle and coal generation, which are the only types of generation currently allowed out of region. (4) A power flow layer should be embedded in LBNL-NEMS to appropriately model and limit transmission.

  2. The Mathematical Model of Power System with Thyristor Controlled Series Capacitor in Long Transmission Line

    Directory of Open Access Journals (Sweden)

    Prechanon Kumkratug

    2012-01-01

    Full Text Available Problem statement: It is becoming increasingly important to fully utilize the existing transmission system assets due to environmental legislation, rights-of-way issues and costs of construction and deregulation policies that introduced in recent years. The Thyristor Controlled Series Capacitor (TCSC has been proposed for the better control power flow and dynamic performance. The exact long transmission line model consists of the resistance and reactance. Most of previous researches studies transient stability performance of the TCSC in SMIB System with neglecting the resistance of the line. Thus the fully capability of the TCSC on transient stability improvement of power system may not be applied. The consideration of the resistance causes in the difficulty of deriving the mathematical model. Approach: This study investigates the effect of the TCSC on transient stability of the power system with consideration the exact long transmission line mode. The concept of two-port network is applied to simplify the mathematical model of the power system. The proposed method is tested on sample system and compared on various cases. Results: The first swing of rotor angle curve of the faulted system without resistance is obviously higher than that of with resistance whereas the second swing of the faulted system without resistance is slightly less than that of with resistance. The system with a TCSC can improve transient stability of power system. Conclusion: It was found from this study that the TCSC and resistance of the line can improve first swing of rotor angle. However, the resistance of the line provides the negative effect on second swing of rotor angle. The simulation results indicate that for practical long line, the resistance is very import parameters for evaluating transient stability of power system.

  3. The Mathematical Model of Power System with Static Var Compensator in Long Transmission Line

    Directory of Open Access Journals (Sweden)

    Prechanon Kumkratug

    2012-01-01

    Full Text Available Problem statement: It is becoming increasingly important to fully utilize the existing transmission system assets due to environmental legislation, rights-of-way issues and costs of construction and deregulation policies that introduced in recent years. The Static Var Compensator (SVC has been proposed for the better control power flow and dynamic performance. The exact long transmission line model consists of the resistance and reactance. Most of previous researches studies transient stability performance of the SVC in SMIB System with neglecting resistance of the line. Thus the fully capability of the SVC on transient stability improvement of power system may not be applied. The consideration of the resistance causes in the difficulty of deriving mathematical model. Approach: This study investigates the effect of the SVC on transient stability of the power system with consideration the exact long transmission line mode. The concept of two-port network is applied to simplify the mathematical model of the power system. The proposed method is tested on sample system and compared on various cases. Results: The first swing of rotor angle curve of the faulted system without resistance is obviously higher than that of with resistance whereas the second swing of the faulted system without resistance is slightly less than that of with resistance. The system with the SVC can improve transient stability of power system. Conclusion: It is found from this study that the SVC and resistance of the line can improve first swing of rotor angle. The resistance of the line provides the negative effect on second swing of rotor angle. The simulation results indicate that for practical long line, the resistance is very import parameters for evaluating transient stability of power system.

  4. Phronesis, a diagnosis and recovery tool for system administrators

    CERN Document Server

    Haen, C; Bonaccorsi, E; Neufeld, N

    2014-01-01

    The LHCb experiment relies on the Online system, which includes a very large and heterogeneous computing cluster. Ensuring the proper behavior of the different tasks running on the more than 2000 servers represents a huge workload for the small operator team and is a 24/7 task. At CHEP 2012, we presented a prototype of a framework that we designed in order to support the experts. The main objective is to provide them with steadily improving diagnosis and recovery solutions in case of misbehavior of a service, without having to modify the original applications. Our framework is based on adapted principles of the Autonomic Computing model, on Reinforcement Learning algorithms, as well as innovative concepts such as Shared Experience. While the submission at CHEP 2012 showed the validity of our prototype on simulations, we here present an implementation with improved algorithms and manipulation tools, and report on the experience gained with running it in the LHCb Online system.

  5. Geographic Information System - Modern Teaching Method in Business Administration

    OpenAIRE

    Irina Albăstroiu; Mihai Felea; Cristinel Vasiliu

    2014-01-01

    The evolution of information and communication technologies has made possible the use of new ways of teaching and learning. Geographic Information System (GIS), one of these new technologies, allows a visual learning environment, facilitates active learning and spatial thinking, and also improves students` skills on using information technologies. The aim of this paper is to examine how GIS applications contribute to the education field but also to present the limitations of their use in the ...

  6. Healthcare Decision Support System for Administration of Chronic Diseases

    OpenAIRE

    Woo, Ji-In; Yang, Jung-Gi; Lee, Young-Ho; Kang, Un-Gu

    2014-01-01

    Objectives A healthcare decision-making support model and rule management system is proposed based on a personalized rule-based intelligent concept, to effectively manage chronic diseases. Methods A Web service was built using a standard message transfer protocol for interoperability of personal health records among healthcare institutions. An intelligent decision service is provided that analyzes data using a service-oriented healthcare rule inference function and machine-learning platform; ...

  7. NASIS data base management system: IBM 360 TSS implementation. Volume 8: Data base administrator user's guide

    Science.gov (United States)

    1973-01-01

    The Data Base Administrator User's Guide for the NASA Aerospace Safety Information System is presented. The subjects discussed are: (1) multi-terminal tasking, (2) data base executive, (3) utilities, (4) maintenance, (5) terminal support, and (6) retrieval subsystem.

  8. Modular VSC converter based HVDC power transmission from offshore wind power plant: Compared to the conventional HVAC system

    DEFF Research Database (Denmark)

    Sharma, Ranjan; Rasmussen, Tonny Wederberg; Jensen, Kim Høj;

    2010-01-01

    The size of wind power plants (WPPs), both physical and in terms of power rating, is rapidly growing. More and more WPPs are commissioned as offshore as well as the distances from the WPP to the coast are increasing. The problems associated with long HVAC sea-cables are well documented. Alternative...... power transmission options with HVDC systems are under consideration. In this paper, a comparison between a conventional HVAC transmission system and a HVDC system equipped with modular voltage source converters is provided. The comparison is based on the total energy transmission capability...... and the energy losses. A complete procedure of evaluating the energy transmission as well as losses in both systems are presented. A brief discussion about the limitations of HVAC transmission is also included in the paper together with advantages and disadvantages of both systems....

  9. CONTROL STRATEGY OF A PARALLEL HYBRID CAR WITH A METAL BELT-PLANETARY GEAR CONTINUOUSLY VARIABLE TRANSMISSION SYSTEM

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    The most remarkable characteristic of a metal belt-planetary gear continuously variable transmission is a wider ratio range and a bigger torque capacity than a conventional metal pushing belt continuously variable transmission. A parallel hybrid car with this transmission system not only can reduce fuel consumption and pollutant emission at a ECE city cycle, but also can keep the motor working in the most efficiency area and can be started by a lower power motor by oneself. At the same time, the continuously variable transmission system can realize the smooth switch between the motor and the engine.

  10. Real-time all-optical OFDM transmission system based on time-domain optical fourier transformation

    DEFF Research Database (Denmark)

    Guan, Pengyu; Kong, Deming; Røge, Kasper Meldgaard;

    2014-01-01

    We propose a novel simple all-optical OFDM transmission system based on time-domain OFT using time-lenses. A real-time 160 Gbit/s DPSK OFDM transmission with 16 decorrelated data subcarriers is successfully demonstrated over 100 km.......We propose a novel simple all-optical OFDM transmission system based on time-domain OFT using time-lenses. A real-time 160 Gbit/s DPSK OFDM transmission with 16 decorrelated data subcarriers is successfully demonstrated over 100 km....

  11. Design of a telemetry system based on wireless power transmission for physiological parameter monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Jia, Zhiwei, E-mail: jiayege@hotmail.com [College of Electrical and Information Engineering, Changsha University of Science and Technology, Changsha (China); Yan, Guozheng; Zhu, Bingquan [820 Institute, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai (China)

    2015-04-15

    An implanted telemetry system for experimental animals with or without anaesthesia can be used to continuously monitor physiological parameters. This system is significant not only in the study of organisms but also in the evaluation of drug efficacy, artificial organs, and auxiliary devices. The system is composed of a miniature electronic capsule, a wireless power transmission module, a data-recording device, and a processing module. An electrocardiograph, a temperature sensor, and a pressure sensor are integrated in the miniature electronic capsule, in which the signals are transmitted in vitro by wireless communication after filtering, amplification, and A/D sampling. To overcome the power shortage of batteries, a wireless power transmission module based on electromagnetic induction was designed. The transmitting coil of a rectangular-section solenoid and a 3D receiving coil are proposed according to stability and safety constraints. Experiments show that at least 150 mW of power could pick up on the load in a volume of Φ10.5 mm × 11 mm, with a transmission efficiency of 2.56%. Vivisection experiments verified the feasibility of the integrated radio-telemetry system.

  12. A unified modeling and control design for precision transmission system with friction and backlash

    Directory of Open Access Journals (Sweden)

    Xiulan Bao

    2016-05-01

    Full Text Available The structural flexibility, nonlinear friction, and backlash are the major factors limiting the control performance of precision transmission systems. If uncompensated, these factors compromise the positioning and tracking accuracy of precision transmission systems and even cause limit cycles and oscillation. In this article, a framework for integrated design from dynamic modeling to controller design is proposed. A multi-state dynamic model is presented, which can unify the modeling for a multi-state, discontinuous system including the motor state, the motion state, the mechanical contact state, and the friction state. Then, a control design method related to the dynamic modeling using perturbation separation of the model parameters is presented. Using the proposed modeling method, a continuous dynamic model is established to include all different partition models. The model comprehensively describes the mechanical and electrical characteristics of the precision transmission system. A robust controller is designed using the proposed control method. Experimental results demonstrate that the proposed modeling method is accurate and the proposed control method significantly improves accuracy and robustness of the controller compared to traditional control methods.

  13. Design of a telemetry system based on wireless power transmission for physiological parameter monitoring

    Science.gov (United States)

    Jia, Zhiwei; Yan, Guozheng; Zhu, Bingquan

    2015-04-01

    An implanted telemetry system for experimental animals with or without anaesthesia can be used to continuously monitor physiological parameters. This system is significant not only in the study of organisms but also in the evaluation of drug efficacy, artificial organs, and auxiliary devices. The system is composed of a miniature electronic capsule, a wireless power transmission module, a data-recording device, and a processing module. An electrocardiograph, a temperature sensor, and a pressure sensor are integrated in the miniature electronic capsule, in which the signals are transmitted in vitro by wireless communication after filtering, amplification, and A/D sampling. To overcome the power shortage of batteries, a wireless power transmission module based on electromagnetic induction was designed. The transmitting coil of a rectangular-section solenoid and a 3D receiving coil are proposed according to stability and safety constraints. Experiments show that at least 150 mW of power could pick up on the load in a volume of Φ10.5 mm × 11 mm, with a transmission efficiency of 2.56%. Vivisection experiments verified the feasibility of the integrated radio-telemetry system.

  14. Design of a telemetry system based on wireless power transmission for physiological parameter monitoring

    International Nuclear Information System (INIS)

    An implanted telemetry system for experimental animals with or without anaesthesia can be used to continuously monitor physiological parameters. This system is significant not only in the study of organisms but also in the evaluation of drug efficacy, artificial organs, and auxiliary devices. The system is composed of a miniature electronic capsule, a wireless power transmission module, a data-recording device, and a processing module. An electrocardiograph, a temperature sensor, and a pressure sensor are integrated in the miniature electronic capsule, in which the signals are transmitted in vitro by wireless communication after filtering, amplification, and A/D sampling. To overcome the power shortage of batteries, a wireless power transmission module based on electromagnetic induction was designed. The transmitting coil of a rectangular-section solenoid and a 3D receiving coil are proposed according to stability and safety constraints. Experiments show that at least 150 mW of power could pick up on the load in a volume of Φ10.5 mm × 11 mm, with a transmission efficiency of 2.56%. Vivisection experiments verified the feasibility of the integrated radio-telemetry system

  15. Safety awareness educational topics for the construction of power transmission systems with smart grid technologies

    Directory of Open Access Journals (Sweden)

    Bryan Hubbard

    2013-09-01

    Full Text Available Power transmission facilities in the U.S. are undergoing a transformation due to the increased use of distributed generation sources such as wind and solar power.  The current power grid system is also antiquated and in need of substantial retrofits to make it more efficient and reliable.  The new energy transmission system being designed and built to optimize power delivery is known as “Smart Grid”.  The increased activity in the construction of power transmission facilities and installation of new technologies into the current power system raises potential safety concerns.  Existing construction management curriculum may include general information about safety training, but does not typically include information about this specialized sector.  The objective of this study was to work with industry to identify key safety topics appropriate for inclusion in an introductory industrial construction course.  Results of interviews with industry identified numerous hazards that are not typically covered in typical construction curricula.  A joint undergraduate and graduate course in industrial construction was created to address these and additional concepts. A survey of the students was performed to determine the effectiveness of the course and also to determine their thoughts about the smart grid technologies and safety training. Information on electrical system hazards is presented along with results of the student surveys.

  16. ICT enabled land administration systems for sustainable development:the Danish way

    OpenAIRE

    Enemark, Stig

    2006-01-01

    This paper analyses the current Land Administration System (LAS) in Denmark with a focus on institutional arrangements, land policies, land information infrastructure, and the four land administration functions: land tenure, land value, land-use, and land development. The analysis, this way, builds on the land management paradigm. Some challenges and barriers are identified and the key initiatives for improvement are described. It is concluded that the system works well in the sense that it s...

  17. Study on the dynamics responses of a transmission system made from carbon nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Yin, Hang; Cai, Kun, E-mail: kuicansj@163.com; Wei, Ning [College of Water Resources and Architectural Engineering, Northwest A and F University, Yangling 712100 (China); Qin, Qing-Hua [Research School of Engineering, The Australian National University, Canberra, Australian Capital Territory 2601 (Australia); Shi, Jiao [Department of Civil and Environmental Engineering, University of Missouri, Columbia, Missouri 65211-2200 (United States)

    2015-06-21

    A rotational transmission system from coaxial carbon nanotubes (CNTs) is investigated using a computational molecular dynamics approach. The system consists of a motor from a single-walled carbon nanotube and a bearing from a double-walled carbon nanotube. The motor has a high fixed rotational frequency and the two ends of the outer tube in the bearing are fixed. The inner tube in the bearing works as a rotor. Because of the interlayer friction in the bearing, configurations of the joint between the adjacent ends of motor and rotor have significant effects on rotational transmission properties. Four factors are considered in simulation, i.e., the bonding types of atoms (sp{sup 1} and sp{sup 2}) on the ends of motor and rotor, the difference between motor and rotor radii, the rotational speed of motor, and the environmental temperature. It is found that the synchronous transmission happens if the sp{sup 1} atoms on the jointed ends of motor and rotor are bonded each other and become new sp{sup 2} atoms. Therefore, the lower difference between radii of motor and rotor, higher temperature of environment leads to synchronous rotational transmission easily. If the environmental temperature is too low (e.g., <150 K), the end of motor adjacent to rotor is easily under buckling and new sp{sup 2} atoms appear, too. With capped CNTs or higher radii difference between rotor and motor at an appropriate temperature, a stable asynchronous rotation of rotor can be generated, and the rotor's frequency varying linearly with motor's frequency between 230 and 270 GHz. A multi-signal transmission device combined with oscillating and rotational motion is proposed for motor and stator shares a same size in radius.

  18. Study on the dynamics responses of a transmission system made from carbon nanotubes

    International Nuclear Information System (INIS)

    A rotational transmission system from coaxial carbon nanotubes (CNTs) is investigated using a computational molecular dynamics approach. The system consists of a motor from a single-walled carbon nanotube and a bearing from a double-walled carbon nanotube. The motor has a high fixed rotational frequency and the two ends of the outer tube in the bearing are fixed. The inner tube in the bearing works as a rotor. Because of the interlayer friction in the bearing, configurations of the joint between the adjacent ends of motor and rotor have significant effects on rotational transmission properties. Four factors are considered in simulation, i.e., the bonding types of atoms (sp1 and sp2) on the ends of motor and rotor, the difference between motor and rotor radii, the rotational speed of motor, and the environmental temperature. It is found that the synchronous transmission happens if the sp1 atoms on the jointed ends of motor and rotor are bonded each other and become new sp2 atoms. Therefore, the lower difference between radii of motor and rotor, higher temperature of environment leads to synchronous rotational transmission easily. If the environmental temperature is too low (e.g., <150 K), the end of motor adjacent to rotor is easily under buckling and new sp2 atoms appear, too. With capped CNTs or higher radii difference between rotor and motor at an appropriate temperature, a stable asynchronous rotation of rotor can be generated, and the rotor's frequency varying linearly with motor's frequency between 230 and 270 GHz. A multi-signal transmission device combined with oscillating and rotational motion is proposed for motor and stator shares a same size in radius

  19. Perceived impact by administrators of psychiatric emergency services after changes in a state's mental health system.

    Science.gov (United States)

    Arfken, Cynthia L; Zeman, Lori Lackman; Koch, Alison

    2006-06-01

    As a safety net, psychiatric emergency services are sensitive to system changes. To determine the impact of a state's changes in its mental health system, administrators of publicly funded psychiatric emergency services were surveyed. They reported few (M=0.8) negative changes in coordination of care but 77% endorsed change in administrative burden (54% saying it negatively affected quality of services). Reporting negative effect of administrative burden was associated with treating more persons with substance abuse problems and greater challenge posed by distance to local providers. These results suggest that impact of state-level changes was not uniform but associated with local characteristics.

  20. LHCb: Phronesis, a diagnosis and recovery tool for system administrators

    CERN Multimedia

    Haen, C; Bonaccorsi, E; Neufeld, N

    2013-01-01

    The backbone of the LHCb experiment is the Online system, which is a very large and heterogeneous computing center. Making sure of the proper behavior of the many different tasks running on the more than 2000 servers represents a huge workload for the small expert-operator team and is a 24/7 task. At the occasion of CHEP 2012, we presented a prototype of a framework that we designed in order to support the experts. The main objective is to provide them with always improving diagnosis and recovery solutions in case of misbehavior of a service, without having to modify the original applications. Our framework is based on adapted principles of the Autonomic Computing model, on reinforcement learning algorithms, as well as innovative concepts such as Shared Experience. While the presentation made at CHEP 2012 showed the validity of our prototype on simulations, we here present a version with improved algorithms, manipulation tools, and report on experience with running it in the LHCb Online system.

  1. Multiplexed Optical Transmission System For Automobiles Using Polymer Fiber With High Heat Resistance

    Science.gov (United States)

    Sasayama, Takao; Asano, Hideki; Taketani, Noriaki

    1989-02-01

    A multiplexed optical transmission system for automobiles utilizing newly developed polymer fiber has been proposed. The system is composed with a star-shaped optical network, in which the ootical signals can be transmitted bi-directionally through polymer optical fiber and optical branches with the central and local controllers. The polymer fiber has been developed for this purpose in order to overcome the conventional problems which prevented its wide use for a long time. The new polymer fiber is fabricated with a thereto-setting resin for core which is pushed out from heating furnace after the process of polymerization. The fiber shows the desirable characteristics for this application, that is, the heat resistance is as high as 200°C, and the transmission loss is as low as 0.5003/m at 660 nm wavelength.

  2. Photonic Crystal Fibres as the Transmission Medium for Future Optical Communication Systems

    DEFF Research Database (Denmark)

    Zsigri, Beata

    2006-01-01

    During this Ph.D. work, air-silica photonic crystal fibres(PCFs) have been investigated for telecommunication applications. PCFs have a complicated cladding structure, where air holes, running along the entire fibre length, ensure light guidance. Photonic crystal fibres can be classified into two...... and index guiding PCFs. Nevertheless, both PCF types exhibit numerous novel properties { not obtainable by standard fibre technology { that are very attractive for optical communication systems. Even though PCFs have now existed already for a decade, their exploitation for telecommunication applications has...... begun only recently. This thesis follows the evolution of PCFs as transmission media from the beginning up to now and presents state-of-the-art results of their various possible system applications. Index guiding PCFs have been investigated for transmission purposes. In this thesis, some of the initial...

  3. Sensor selection of helicopter transmission systems based on physical model and sensitivity analysis

    Institute of Scientific and Technical Information of China (English)

    Lyu Kehong; Tan Xiaodong; Liu Guanjun; Zhao Chenxu

    2014-01-01

    In the helicopter transmission systems, it is important to monitor and track the tooth damage evolution using lots of sensors and detection methods. This paper develops a novel approach for sensor selection based on physical model and sensitivity analysis. Firstly, a physical model of tooth damage and mesh stiffness is built. Secondly, some effective condition indicators (CIs) are presented, and the optimal CIs set is selected by comparing their test statistics according to Mann-Kendall test. Afterwards, the selected CIs are used to generate a health indicator (HI) through sen slop estimator. Then, the sensors are selected according to the monotonic relevance and sensitivity to the damage levels. Finally, the proposed method is verified by the simulation and experimental data. The results show that the approach can provide a guide for health monitor-ing of helicopter transmission systems, and it is effective to reduce the test cost and improve the system’s reliability.

  4. Sensor selection of helicopter transmission systems based on physical model and sensitivity analysis

    Directory of Open Access Journals (Sweden)

    Lyu Kehong

    2014-06-01

    Full Text Available In the helicopter transmission systems, it is important to monitor and track the tooth damage evolution using lots of sensors and detection methods. This paper develops a novel approach for sensor selection based on physical model and sensitivity analysis. Firstly, a physical model of tooth damage and mesh stiffness is built. Secondly, some effective condition indicators (CIs are presented, and the optimal CIs set is selected by comparing their test statistics according to Mann–Kendall test. Afterwards, the selected CIs are used to generate a health indicator (HI through sen slop estimator. Then, the sensors are selected according to the monotonic relevance and sensitivity to the damage levels. Finally, the proposed method is verified by the simulation and experimental data. The results show that the approach can provide a guide for health monitoring of helicopter transmission systems, and it is effective to reduce the test cost and improve the system’s reliability.

  5. Multichannel Adaptive Polarization Mode Dispersion Compensation with One Compensator in Dense Wavelength Division Multiplexing Transmission Systems

    Institute of Scientific and Technical Information of China (English)

    ZHANG Qi; CHEN Ming-hua; ZHANG Ji-yu; XIE Shi-zhong

    2007-01-01

    A simple two-section polarization mode dispersion(PMD) compensator is proposed for multichannel PMD compensation, which can compensate two or even more channels simultaneously. Because of the statistical characteristics and the frequency-dependence of PMD, for current single mode fiber with moderate PMD, the probability that all channels are severely degraded at the same time is extremely small, which makes it possible to compensate a dense wavelength division multiplexing(DWDM) transmission system with moderate PMD using this compensator. It is shown that the outage probability of a 40×43Gb/s DWDM transmission system using this compensator is decreased significantly from 3.6×10-3 to 3.6×10-5.

  6. Analysis of the ITER low field side reflectometer transmission line system.

    Science.gov (United States)

    Hanson, G R; Wilgen, J B; Bigelow, T S; Diem, S J; Biewer, T M

    2010-10-01

    A critical issue in the design of the ITER low field side reflectometer is the transmission line (TL) system. A TL connects each launcher to a diagnostic instrument. Each TL will typically consist of ∼42 m of corrugated waveguide and up to ten miter bends. Important issues for the performance of the TL system are mode conversion and reflections. Minimizing these issues are critical to minimizing standing waves and phase errors. The performance of TL system is analyzed and recommendations are given.

  7. Shaft torsional oscillation interactions between turbo-generators in parallel in series compensated transmission systems

    Energy Technology Data Exchange (ETDEWEB)

    Mello, F.P. de

    1994-12-31

    Several investigators have raised the possibility of interaction between shaft systems of parallel units, particularly among identical units. The question addressed in this paper is the significance of this interaction between shaft systems of units coupled through the electrical system. A time domain model of two parallels units connected to an infinite bus trough a series compensated transmission is used to evaluate the phenomena. The same model is used to extract pertinent frequency response functions by Fourier processing of pulse response tests from which a frequency response analysis is performed to lend additional insight into the phenomena. (author) 8 refs., 13 figs., 3 tabs.

  8. Minimum fuel control of a vehicle with a continuously variable transmission. [control system simulation

    Science.gov (United States)

    Burghart, J. H.; Donoghue, J. F.

    1980-01-01

    The design and evaluation of a control system for a sedan with a heat engine and a continuously variable transmission, is considered in a effort to minimize fuel consumption and achieve satisfactory dynamic response of vehicle variables as the vehicle is driven over a standard driving cycle. Even though the vehicle system was highly nonlinear, attention was restricted to linear control algorithms which could be easily understood and implemented demonstrated by simulation. Simulation results also revealed that the vehicle could exhibit unexpected dynamic behavior which must be taken into account in any control system design.

  9. A digital, decentralized power station control system with bus-transmission facilitates the problem of backfitting

    International Nuclear Information System (INIS)

    Current NPP control equipment technology is essentially characterized by the transmission of information in parallel using individual cables, and utilizes hardwired techniques for the processing of information. Progress in the area of semiconductor development characterized by micro-processors and LSI-circuits, has opened up new possibilities for the solution of the control tasks. The new power station control system PROCONTROL P utilizes these possibilities

  10. Link adaptation algorithm for distributed coded transmissions in cooperative OFDMA systems

    DEFF Research Database (Denmark)

    Varga, Mihaly; Badiu, Mihai Alin; Bota, Vasile

    2015-01-01

    This paper proposes a link adaptation algorithm for cooperative transmissions in the down-link connection of an OFDMA-based wireless system. The algorithm aims at maximizing the spectral efficiency of a relay-aided communication link, while satisfying the block error rate constraints at both the ...... adaptation algorithm has linear complexity with the number of available resource blocks, while still provides a very good performance, as shown by simulation results....

  11. Damage Detection Strategies in Structural Health Monitoring of Overhead Power Transmission System

    OpenAIRE

    Skarbek, Lukasz; Zak, Arkadiusz; Ambroziak, Dominik

    2014-01-01

    Overhead power transmission lines, their supporting towers, insulators and other elements create a highly distributed system that is vulnerable to damage. Typical damage scenarios cover cracking of foundation, breakage of insulators, loosening of rivets, as well as cracking and breakage of lines. Such scenarios may result from various factors: groundings, lightning strikes, floods, earthquakes, aeolian vibrations, conductors galloping, icing, and also include sabotage or terrorist attacks. It...

  12. Power-Voltage Characteristics of Power System with the Short Transmission Line

    OpenAIRE

    Prechanon Kumkratug

    2012-01-01

    Problem statement: Power-Voltage curve provides very important information for voltage stability analysis. The exact short transmission line model consists of the resistance and reactance. The resistance causes in the active line loss. It is not easy task to achieve the power-voltage curve characteristics of power system with the exact short line model. Approach: This study applied the concept of the Newton-Raphson method to iteratively solve the nonlinear power flow equations. The power-volt...

  13. Power-Voltage Characteristics of Power System with the Medium Transmission Line

    OpenAIRE

    Prechanon Kumkratug

    2012-01-01

    Problem statement: Power-Voltage curve provides very important information for voltage stability analysis. The exact medium transmission line model consists of the resistance and the reactance. The resistance causes in the active line loss. It is not easy task to achieve the power-voltage curve characteristics of power system with the exact medium line model. Approach: This study applies the concept of the Newton-Raphson method to iteratively solve the nonlinear power flow equations. The Powe...

  14. Power-Voltage Characteristics of Power System with the Long Transmission Line

    OpenAIRE

    Prechanon Kumkratug

    2012-01-01

    Problem statement: Power- Voltage curve provides very important information for voltage stability analysis. The exact long transmission line model consists of the resistance and the reactance. The resistance causes in the active line loss. It is not easy task to achieve the power-voltage curve characteristics of power system with the exact long line model. Approach: This study applies the concept of the Newton-Raphson method to iteratively solve the nonlinear power flow equations. The Power-V...

  15. Principles of functioning of the transmission mechanism of the monetary system in international business

    OpenAIRE

    Poliakova Iana O.

    2014-01-01

    Modern international economic relations are characterised with reduction of rates of economic growth of the majority of developed economic systems, gradual oligopolisation of international markets, domination of private investors interests in political relations, growth of intensity and frequency of local, regional and international economic crises, which negatively influences the tendencies of formation of main directions of transmission and use of capital. Consideration of theoretical groun...

  16. A Common Definition of the System Operators' Core Activities[Electric Power Transmission System Operator

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-02-15

    In this report a common definition of the system operator's core activities in the Nordic countries is identified and also a list of non-core activities is introduced. As a starting point the common tasks for system responsibility as identified by Nordel has been used for the work. The term TSO (Transmission System Operator) is employed as a common denominator in the report. It is found out that the TSOs carry out common core activities in the roles as a transmission operator, a system operator and a balance settlement responsible. The core activities for the TSO as a transmission network operator are: Maintain the adequate transmission system in the long run and network development plan on the national as well as on the Nordic level using sophisticated analysis and planning methods and tools. Plan the transmission network on the national as well as on the Nordic level utilising new investments, renewal and maintenance of existing network components so that the network is secure to operate and adequate transmission capacity is guaranteed. Aim at timely network expansions using enhanced information exchange between the Nordic TSOs, and on the national level between the TSO and distribution and regional network operators, large consumers and large producers. Secure the technical compatibility with networks across the border and within a country by establishing connection requirements on the national level and ensuring that the national requirements are compatible across the Nordic power system. The core activities for the TSO as a system operator are: Define common technical requirements for the secure system operation using common planning, operation, connection and data exchange procedures. Secure the system operation with the operational planning for the following year by using information exchange between TSOs enabling the TSOs to make the best possible forecast of the global grid situation in order to assess the flows in their network and the available

  17. Comparison of mechanical and hydraulic transmission systems for aerogenerators. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    1982-12-01

    The report presented is concerned with studies of three types of aerogenerator transmission systems namely, fixed pitch rotor hydraulic, variable pitch rotor mechanical, and fixed pitch rotor mechanical, each type being considered in three sizes. The study covers systems design, control, performance, reliability/availability, weight, wind speed effects from three sites, energy yields, and energy costs. The principal results and conclusions discussed include that for many applications, the principal advantages of the hydraulic system compared with the variable pitch mechanical system are unlikely to outweigh its principal disadvantages e.g. lower energy yield, higher energy costs, and development requirements, the fixed pitch rotor mechanical system is the least attractive of the three types of system, and for all the systems, high wind speed sites are preferred because they yield more energy at significantly lower unit energy costs.

  18. Interference Robust Transmission for the Downlink of an OFDM-Based Mobile Communications System

    Directory of Open Access Journals (Sweden)

    Markus Konrad

    2008-01-01

    Full Text Available Radio networks for future mobile communications systems, for example, 3GPP Long-Term Evolution (LTE, are likely to use an orthogonal frequency division multiplexing- (OFDM- based air interface in the downlink with a frequency reuse factor of one to avoid frequency planning. Therefore, system capacity is limited by interference, which is particularly crucial for mobile terminals with a single receive antenna. Nevertheless, next generation mobile communications systems aim at increasing downlink throughput. In this paper, a single antenna interference cancellation (SAIC algorithm is introduced for amplitude-shift keying (ASK modulation schemes in combination with bit-interleaved coded OFDM. By using such a transmission strategy, high gains in comparison to a conventional OFDM transmission with quadrature amplitude modulation (QAM can be achieved. The superior performance of the novel scheme is confirmed by an analytical bit-error probability (BEP analysis of the SAIC receiver for a single interferer, Rayleigh fading, and uncoded transmission. For the practically more relevant multiple interferer case we present an adaptive least-mean-square (LMS and an adaptive recursive least-squares (RLS SAIC algorithm. We show that in particular the RLS approach enables a good tradeoff between performance and complexity and is robust even to multiple interferers.

  19. Scalable Heuristics for Planning, Placement and Sizing of Flexible AC Transmission System Devices

    Energy Technology Data Exchange (ETDEWEB)

    Frolov, Vladmir [Skolkovo Institute of Science and Technology, Skolkovo (Russia); Backhaus, Scott N. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Chertkov, Michael [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-07-02

    Aiming to relieve transmission grid congestion and improve or extend feasibility domain of the operations, we build optimization heuristics, generalizing standard AC Optimal Power Flow (OPF), for placement and sizing of Flexible Alternating Current Transmission System (FACTS) devices of the Series Compensation (SC) and Static VAR Compensation (SVC) type. One use of these devices is in resolving the case when the AC OPF solution does not exist because of congestion. Another application is developing a long-term investment strategy for placement and sizing of the SC and SVC devices to reduce operational cost and improve power system operation. SC and SVC devices are represented by modification of the transmission line inductances and reactive power nodal corrections respectively. We find one placement and sizing of FACTs devices for multiple scenarios and optimal settings for each scenario simultaneously. Our solution of the nonlinear and nonconvex generalized AC-OPF consists of building a convergent sequence of convex optimizations containing only linear constraints and shows good computational scaling to larger systems. The approach is illustrated on single- and multi-scenario examples of the Matpower case-30 model.

  20. ELECTRODYNAMICS OF TRANSMISSION AND LOSSES OF POWER IN THE DEVICES OF ELECTRIC TRACTION SYSTEMS

    Directory of Open Access Journals (Sweden)

    M. O. Kostin

    2014-01-01

    Full Text Available Purpose. Theoretical justification of the "field" approach (based on electromagnetic field to the transmission and losses of power in the devices of traction power supply systems and electric rolling stock. Methodology. The methods of electromagnetic field theory and, in particular, the theory and practice of electromagnetic energy transmission based on the concept of the Poynting vector and elements of the theory of propagation, reflection and refraction of plane electromagnetic waves were used. Findings. Theoretical studies of electromagnetic energy transmission from the traction substation to the electric rolling stock through dielectric (air surrounding traction network: between the contact wire and the rail were carried out. It is proposed strategic designing "squat" (low types of electric rolling stock. The components of electric energy flow through the roof of electric rolling stock and its frontal part of the body were estimated. This allows reliable etimating active power losses in electric traction system. To compensate the reactive power consumed by electric rolling stock, which is conditioned by standing waves, it is proposed (for extinction of the the last to develop and put in front of electric rolling stock the layer of particular environment with the necessary parameters. Originality. The "field" principle of the power transmission analysis and its losses arising in electric traction system was first proposed. The laws of motion of electromagnetic energy flows through the roof and the frontal part of the body of electric rolling stock were established. Practical value. An expression of the absolute value of the Poynting vector in the points of dielectric (air between the contact wire and the rail was obtained. This allows assessing the highest density of energy, which is transferred to the time unit and predicting the main dimensions of the unit of electric rolling stock. The energy indices of the roof of electric rolling stock

  1. Asymmetric multi-input multi-output system in visible light communication for polarization-tolerant polarization division multiplexing transmission

    Science.gov (United States)

    Kim, Sung-Jin; Kwon, Do-Hoon; Yang, Se-Hoon; Han, Sang-Kook

    2016-03-01

    We propose an asymmetric 3×2 multi-input multi-output (MIMO) system for polarization division multiplexing (PDM) transmission in visible light communication (VLC). In PDM transmission, independent channels are constructed by polarization orthogonality, which is vulnerable to misalignment of polarization between the transmitter and the receiver. Although PDM-based VLC system may not maintain polarization orthogonality, the proposed asymmetric MIMO system can achieve the polarization diversity required for a multichannel system. We experimentally demonstrate the performance enhancement of PDM VLC transmission using the proposed asymmetric 3×2 MIMO technique.

  2. Reliability assessment of generation and transmission systems using fault-tree analysis

    International Nuclear Information System (INIS)

    This paper presents a method that integrates deterministic approach with fault-tree analysis for reliability assessment of a composite system (generation and transmission in power systems). The contingency screening is conducted in the first step. The results are further classified into three clusters in the second step: normal, local trouble and system trouble. The fault-tree analysis is used to assess the reliability of the composite system in the third step. Finally, Risk Reduction Worth is adopted as a measure of importance for identifying the crucial element that has significant impact on the reliability. In this paper, a composite system in Taiwan serves as an example for illustrating the simulation results attained by the proposed method. The simulation results, verified by Siemens PTI PSS/E TPLAN software package, show that the proposed method is applicable for large scale power systems.

  3. Independent transmission system operators and their role in maintaining reliability in a restructured electric power industry

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-01-01

    This report summarizes the current status of proposals to form Independent System Operators (ISOs) to operate high-voltage transmission systems in the United States and reviews their potential role in maintaining bulk power system reliability. As background information, the likely new industry structure, nature of deregulated markets, and institutional framework for bulk power system reliability are reviewed. The report identifies issues related to the formation of ISOs and their roles in markets and in reliability, and describes potential policy directions for encouraging the formation of effective ISOs and ensuring bulk system reliability. Two appendices are provided, which address: (1) system operation arrangements in other countries, and (2) summaries of regional U.S. ISO proposals.

  4. Analysis of operations and cyber security policies for a system of cooperating Flexible Alternating Current Transmission System (FACTS) devices.

    Energy Technology Data Exchange (ETDEWEB)

    Phillips, Laurence R.; Tejani, Bankim; Margulies, Jonathan; Hills, Jason L.; Richardson, Bryan T.; Baca, Micheal J.; Weiland, Laura

    2005-12-01

    Flexible Alternating Current Transmission Systems (FACTS) devices are installed on electric power transmission lines to stabilize and regulate power flow. Power lines protected by FACTS devices can increase power flow and better respond to contingencies. The University of Missouri Rolla (UMR) is currently working on a multi-year project to examine the potential use of multiple FACTS devices distributed over a large power system region in a cooperative arrangement in which the FACTS devices work together to optimize and stabilize the regional power system. The report describes operational and security challenges that need to be addressed to employ FACTS devices in this way and recommends references, processes, technologies, and policies to address these challenges.

  5. Stability analysis of transmission system with high penetration of distributed generation

    Energy Technology Data Exchange (ETDEWEB)

    Reza, M.

    2006-12-21

    Nowadays, interest in generating electricity using decentralized generators of relatively small scale ('distributed generation', DG) is increasing. This work deals with the impact of implementing DG on the transmission system transient stability, with the emphasis on a potential transition from a 'vertical power system' to a 'horizontal power system. A problem in power systems is maintaining synchronous operation of all (centralized) synchronous machines. This stability problem associated is called rotor angle stability. In this work, the impact of the DG implementation on this is investigated. The impact of DG levels on the system transient stability when the increasing DG level is followed by a reduction of centralized generators in service resulting in a 'vertical to horizontal' transformation of the power system is also investigated. Furthermore, a stochastic analysis is used to study the transient stability of the power systems. The results show that including the stochastic behavior of DG leads to a more complete and detailed view of the system performance. Finally, the situation when the power system is pushed towards a scenario, where DG penetration reaches a level that covers the total load of the original power system (100% DG level) is investigated. The research performed in this work indicates that from the transmission system stability point of view, if higher DG penetration levels are coming up, sufficient inertia and voltage support must be installed. Furthermore, one should be aware of the fact that the system behaves stochastically, especially with DG. To a certain extent regional balancing of power can be performed by local voltage control.

  6. Application of Wireless Power Transmission Systems in Wireless Capsule Endoscopy: An Overview

    Directory of Open Access Journals (Sweden)

    Md Rubel Basar

    2014-06-01

    Full Text Available Wireless capsule endoscopy (WCE is a promising technology for direct diagnosis of the entire small bowel to detect lethal diseases, including cancer and obscure gastrointestinal bleeding (OGIB. To improve the quality of diagnosis, some vital specifications of WCE such as image resolution, frame rate and working time need to be improved. Additionally, future multi-functioning robotic capsule endoscopy (RCE units may utilize advanced features such as active system control over capsule motion, drug delivery systems, semi-surgical tools and biopsy. However, the inclusion of the above advanced features demands additional power that make conventional power source methods impractical. In this regards, wireless power transmission (WPT system has received attention among researchers to overcome this problem. Systematic reviews on techniques of using WPT for WCE are limited, especially when involving the recent technological advancements. This paper aims to fill that gap by providing a systematic review with emphasis on the aspects related to the amount of transmitted power, the power transmission efficiency, the system stability and patient safety. It is noted that, thus far the development of WPT system for this WCE application is still in initial stage and there is room for improvements, especially involving system efficiency, stability, and the patient safety aspects.

  7. The Cost and Benefit of Bulk Energy Storage in the Arizona Power Transmission System

    Science.gov (United States)

    Ruggiero, John

    This thesis addresses the issue of making an economic case for energy storage in power systems. Bulk energy storage has often been suggested for large scale electric power systems in order to levelize load; store energy when it is inexpensive and discharge energy when it is expensive; potentially defer transmission and generation expansion; and provide for generation reserve margins. As renewable energy resource penetration increases, the uncertainty and variability of wind and solar may be alleviated by bulk energy storage technologies. The quadratic programming function in MATLAB is used to simulate an economic dispatch that includes energy storage. A program is created that utilizes quadratic programming to analyze various cases using a 2010 summer peak load from the Arizona transmission system, part of the Western Electricity Coordinating Council (WECC). The MATLAB program is used first to test the Arizona test bed with a low level of energy storage to study how the storage power limit effects several optimization out-puts such as the system wide operating costs. Very high levels of energy storage are then added to see how high level energy storage affects peak shaving, load factor, and other system applications. Finally, various constraint relaxations are made to analyze why the applications tested eventually approach a constant value. This research illustrates the use of energy storage which helps minimize the system wide generator operating cost by "shaving" energy off of the peak demand.

  8. A social-based cyber-physical system for distributed message transmission

    Science.gov (United States)

    Chen, Kang; Shen, Haiying

    2014-06-01

    The explosive increase of the availability of personal mobile devices has brought about a significant amount of peer-to-peer communication opportunities upon their encountering, which can be exploited to realize distributed message transmission among mobile devices. However, the opportunistic encountering among mobile devices, which is determined by the mobility of their holders, has introduced great difficulties on efficiently transmitting a message to its designated destination. Actually, people usually present a certain pattern on daily mobility. Further, device holders often belong to a certain social network community. Therefore, in this paper, we propose a social- based cyber-physical system for distributed message transmission, namely SocMessaging, by integrating both the mobility pattern and the social network of device holders. When selecting an encountered node for message relay, in addition to the node's historical encountering records with the destination node, SocMessaging also considers its social closeness with the destination node. Then, the message is always transmitted to the node that is most likely to meet its destination. As a result, SocMessaging closely connects the cyber world (i.e., network), physical world (i.e., people) and social network (i.e., social connection). Finally, our experimental results demonstrate the efficiency of the proposed system in message transmission between device holders.

  9. Enhancing power transfer capability through flexible AC transmission system devices:a review

    Institute of Scientific and Technical Information of China (English)

    Fadi M ALBATSH; Saad MEKHILEF; Shameem AHMAD; H MOKHLIS; M A HASSAN

    2015-01-01

    Global demand for power has significantly increased, but power generation and transmission capacities have not increased proportionally with this demand. As a result, power consumers suffer from various problems, such as voltage and frequency instability and power quality issues. To overcome these problems, the capacity for available power transfer of a transmission network should be enhanced. Researchers worldwide have addressed this issue by using flexible AC transmission system (FACTS) devices. We have conducted a comprehensive review of how FACTS controllers are used to enhance the avail-able transfer capability (ATC) and power transfer capability (PTC) of power system networks. This review includes a discussion of the classification of different FACTS devices according to different factors. The popularity and applications of these devices are discussed together with relevant statistics. The operating principles of six major FACTS devices and their application in increasing ATC and PTC are also presented. Finally, we evaluate the performance of FACTS devices in ATC and PTC im-provement with respect to different control algorithms.

  10. Natural Gas Transmission and Distribution Model of the National Energy Modeling System. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-01-01

    The Natural Gas Transmission and Distribution Model (NGTDM) is the component of the National Energy Modeling System (NEMS) that is used to represent the domestic natural gas transmission and distribution system. The NGTDM is the model within the NEMS that represents the transmission, distribution, and pricing of natural gas. The model also includes representations of the end-use demand for natural gas, the production of domestic natural gas, and the availability of natural gas traded on the international market based on information received from other NEMS models. The NGTDM determines the flow of natural gas in an aggregate, domestic pipeline network, connecting domestic and foreign supply regions with 12 demand regions. The purpose of this report is to provide a reference document for model analysts, users, and the public that defines the objectives of the model, describes its basic design, provides detail on the methodology employed, and describes the model inputs, outputs, and key assumptions. Subsequent chapters of this report provide: an overview of NGTDM; a description of the interface between the NEMS and NGTDM; an overview of the solution methodology of the NGTDM; the solution methodology for the Annual Flow Module; the solution methodology for the Distributor Tariff Module; the solution methodology for the Capacity Expansion Module; the solution methodology for the Pipeline Tariff Module; and a description of model assumptions, inputs, and outputs.

  11. Effect of bulk modulus on performance of a hydrostatic transmission control system

    Indian Academy of Sciences (India)

    Ali Volkan Akkaya

    2006-10-01

    In this paper, we examine the performance of PID (proportional integral derivative) and fuzzy controllers on the angular velocity of a hydrostatic transmission system by means of Matlab-Simulink. A very novel aspect is that it includes the analysis of the effect of bulk modulus on system control. Simulation results demonstrates that bulk modulus should be considered as a variable parameter to obtain a more realistic model. Additionally, a PID controller is insufficient in presence of variable bulk modulus, whereas a fuzzy controller provides robust angular velocity control.

  12. Controller design for networked control system with data packet dropout and transmission delays

    Institute of Scientific and Technical Information of China (English)

    Xinping GUAN; Shuangfeng DAI; Chengnian LONG

    2007-01-01

    In this paper, the stabilization problem for a class of networked control systems (NCSs) with data packet dropouts and transmission time delays is considered, where the delays are time-varying and uncertain, the data packet dropout is modeled as a two-state Markov chain. To compensate the lost packet, a data packet dropout compensator is established. Thus a more realistic model for such NCSs is presented. Sufficient conditions for the stabilization of the new resulting system are derived in the form of linear matrix inequalities (LMIs). Numerical example illustrates the solvability and effectiveness of the results.

  13. Prospective application of advanced series compensation to improve transmission system performance

    Energy Technology Data Exchange (ETDEWEB)

    Gama, C.A.; Scavassa, J.L.; Silva, W.M. da; Silva, J.M.M. da; Ponte, J.R. [ELETRONORTE, Brasilia, DF (Brazil)

    1994-12-31

    This paper describes the main aspects and results of the planning studies undertaken to evaluate the technical benefits of using Thyristor Controlled Series Compensation (TCSC), in a large 500 kV transmission system (Brazilian North-Northeast system). TCSC controllers design and simplified models for digital non-linear time domain simulations are discussed. The proposed controllers are tuned and used to support the comparative analysis between controlled and fixed series compensation. The relevant conclusions concerning this comparison are highlighted. (author) 2 refs., 14 figs., 3 tabs.

  14. A Horn-to-Horn Power Transmission System at Terahertz Frequencies

    Science.gov (United States)

    Gonzalez, A.; Uzawa, Y.; Fujii, Y.; Kaneko, K.; Kuroiwa, K.

    2011-11-01

    A horn-to-horn power transmission system at Terahertz frequencies has been designed and tested. Power is generated at microwave frequencies and then frequency multiplied to the band 799-938 GHz. The resultant signal is radiated by a diagonal horn and redirected by two identical elliptical mirrors to another diagonal horn located far away. Useful design equations have been derived for the proposed system. The concept has been proven by careful measurements and utilized for the local oscillator injection in the Atacama Large Millimeter Array (ALMA) Band-10 receiver.

  15. High power switch mode linear amplifiers for flexible ac transmission system

    Energy Technology Data Exchange (ETDEWEB)

    Mwinyiwiwa, B.; Wolanski, Z.; Ooi, B.T. [McGill Univ., Montreal, Quebec (Canada). Dept. of Electrical Engineering

    1996-10-01

    The Pulse Width Modulation (PWM) technique has been proposed for the force-commutated Shunt and Series VAR Controllers and Unified Power Flow Controllers in Flexible AC Transmission Systems. The PWM converters can be operated as linear amplifiers of constant gain so that treasure trove of linear control system theory can be brought to bear more easily when applying feedback controls. For example, pole-placement and active filtering have been successfully applied in laboratory models. This paper is written as a tutorial describing the stages of signal processing: modulation, amplification and demodulation, without reference to power electronics since the solid-state switches are modelled as ON-OFF switches.

  16. Harmonics in Offshore Wind Power Plants Employing Power Electronic Devices in the Transmission System

    DEFF Research Database (Denmark)

    Glasdam, Jakob Bærholm

    Introduction The trend in power generation is to partly replace conventional power plants with renewable energy sources. Offshore wind power has been selected to take up a significant proportion of the renewable energy production. The grid codes have been updated to accommodate the rising share...... of wind power. The onshore as well as offshore wind power plants (OWPPs) therefore have to meet the same stringent requirement as the conventional power plants. This can be accommodated by employment of flexible alternating current transmission system (FACTS) devices, such as the static compensator...... gives rise to a number of challenges to the wind power industry with regard to construction, installation as well as transmission of the generated energy. The STATCOM and the voltage-sourced converter high-voltage direct current (VSC-HVDC) are attractive solutions for grid connection of remotely located...

  17. Composite second-order performance improvement in optical fibre CATV transmission system using chirped fibre grating

    Institute of Scientific and Technical Information of China (English)

    Ye Qing; Liu Feng; Cai Hai-Wen; Qu Rong-Hui; Fang Zu-Jie

    2005-01-01

    Theoretically, we analyse the dispersion compensation characteristics of the chirped fibre grating (CFG) in an optical fibre cable television (CATV) system and obtain the analytic expression of the composite second-order (CSO)distortion using the time-domain form of the field envelope wave equation. The obtained result is in good agreement with the numerical simulation result. Experimentally, we verify the result by making use of the tunable characteristics of CFG to change the dispersion compensation amount and obtain an optimal CSO performance in a 125km fibre transmission link. Both the theoretical and experimental results show that the CSO performance can be improved by properly choosing the dispersion compensation amount for a certain fibre transmission link.

  18. Multiagent System-Based Distributed Coordinated Control for Radial DC Microgrid Considering Transmission Time Delays

    DEFF Research Database (Denmark)

    Dou, Chun-Xia; Yue, Dong; Guerrero, Josep M.;

    2016-01-01

    This paper focuses on a multi-agent based distributed coordinated control for radial DC microgrid considering trans-mission time delays. Firstly, a two-level multi-agent system is constructed, where local control is formulated based on local states and executed by means of the first-level agent...... units. Moreover, the distributed coordinated controller is designed by means of delay-dependent H∞ robust control method taking into account transmission time delays. Finally, the validity of the proposed control scheme is demonstrated by means of simulation results....... controller. For pur-pose of robust stability, the local control is designed as local state-feedback based H∞ robust controller. It is worth mention-ing that the distributed coordinated control consists of local state feedback control and decoupling coordinated control law that only come from adjacent DER...

  19. Study on Power Supply System by Using CT in High-Voltage Transmission Lines

    Directory of Open Access Journals (Sweden)

    He Zhi-Min

    2013-10-01

    Full Text Available In online monitoring of the transmission line, its power supply is one of the key issues. This study presents a device using special transformer which can induce power to supply the high side circuitry. The front-end of the protection device includes output-power-control circuitry, which can take output-power limited to a small range. At the back side it contains rechargeable lithium batteries. By using the reasonable control strategy, it can provide a stable output-power at the transmission line current ranging from 40 to 1500A. And in the larger current the fever of transformer is not serious. Experiments show that the power supply system has the high reliability and efficiency.

  20. Visible CWDM system design for Multi-Gbit/s transmission over SI-POF

    Science.gov (United States)

    Vázquez, Carmen; Pinzón, Plinio Jesús; Pérez, Isabel

    2015-01-01

    In order to increase the data rates of Multi-Gbit/s links based on large core step index (SI) plastic optical fibers (POF), different modulation scenes have been proposed. Another option is to use multiple optical carriers for parallel transmission of communication channels over the same fiber. Some designs to reach data rates of 14.77 Gb/s in 50 m, with 4 channels have been developed by off line processing. In this work, designs to test the potential of real Multi- Gbit/s transmission systems using commercial products are reported. Special care in designing low insertion loss multiplexers and demultiplexers is carried out to allow for greener solutions in terms of power consumption.