WorldWideScience

Sample records for administration transmission system

  1. 77 FR 26275 - Bonneville Power Administration; Montana-to-Washington Transmission System Upgrade Project EIS

    Science.gov (United States)

    2012-05-03

    ... Bonneville Power Administration; Montana-to-Washington Transmission System Upgrade Project EIS AGENCY...``''sts for long-term transmission service. During the NOS process, utilities and power generators (including wind generators and power marketers) requested the use of BPA's transmission system to...

  2. Nanoformulations of Rilpivirine for Topical Pericoital and Systemic Coitus-Independent Administration Efficiently Prevent HIV Transmission.

    Directory of Open Access Journals (Sweden)

    Martina Kovarova

    2015-08-01

    Full Text Available Vaginal HIV transmission accounts for the majority of new infections worldwide. Currently, multiple efforts to prevent HIV transmission are based on pre-exposure prophylaxis with various antiretroviral drugs. Here, we describe two novel nanoformulations of the reverse transcriptase inhibitor rilpivirine for pericoital and coitus-independent HIV prevention. Topically applied rilpivirine, encapsulated in PLGA nanoparticles, was delivered in a thermosensitive gel, which becomes solid at body temperature. PLGA nanoparticles with encapsulated rilpivirine coated the reproductive tract and offered significant protection to BLT humanized mice from a vaginal high-dose HIV-1 challenge. A different nanosuspension of crystalline rilpivirine (RPV LA, administered intramuscularly, protected BLT mice from a single vaginal high-dose HIV-1 challenge one week after drug administration. Using transmitted/founder viruses, which were previously shown to establish de novo infection in humans, we demonstrated that RPV LA offers significant protection from two consecutive high-dose HIV-1 challenges one and four weeks after drug administration. In this experiment, we also showed that, in certain cases, even in the presence of drug, HIV infection could occur without overt or detectable systemic replication until levels of drug were reduced. We also showed that infection in the presence of drug can result in acquisition of multiple viruses after subsequent exposures. These observations have important implications for the implementation of long-acting antiretroviral formulations for HIV prevention. They provide first evidence that occult infections can occur, despite the presence of sustained levels of antiretroviral drugs. Together, our results demonstrate that topically- or systemically administered rilpivirine offers significant coitus-dependent or coitus-independent protection from HIV infection.

  3. Bonneville Power Administration Transmission System Vegetation Management Program - Final Environmental Impact Statement

    Energy Technology Data Exchange (ETDEWEB)

    N/A

    2000-06-23

    Bonneville is responsible for maintaining a network of 24,000 kilometers (km) or 15,000 miles (mi.) of electric transmission lines and 350 substations in a region of diverse vegetation. This vegetation can interfere with electric power flow, pose safety problems for us and the public, and interfere with our ability to maintain these facilities. We need to (1) keep vegetation away from our electric facilities; (2) increase our program efficiency and consistency; (3) review herbicide use (under increased public scrutiny); and (4) maximize the range of tools we can use while minimizing environmental impact (Integrated Vegetation Management). This Final Environmental Impact Statement (FEIS) establishes Planning Steps for managing vegetation for specific projects (to be tiered to this Environmental Impact Statement (EIS)). In addition to No Action (current practice), alternatives are presented for Rights-of-way, Electric Yards, and Non-electric Facilities (landscaping, work yards). Four vegetation control methods are analyzed manual, mechanical, herbicide, and biological. Also evaluated are 23 herbicide active ingredients and 4 herbicide application techniques (spot, localized, broadcast, and aerial). For rights-of-way, we consider three sets of alternatives: alternative management approaches (time-driven or establishing low-growing plant communities); alternative method packages; and, if herbicides are in a methods package, alternative vegetation selections (noxious weeds, deciduous, or any vegetation). For electric yards, one herbicide-use alternative is considered. For non-electric facilities, two method package alternatives are considered. For rights-of-way, the environmentally preferred alternative(s) would use manual, mechanical, and biological control methods, as well as spot and localized herbicide applications for noxious and deciduous plant species; the BPA-preferred alternative(s) would add broadcast and aerial herbicide applications, and would use herbicides

  4. Systemic administration of antiretrovirals prior to exposure prevents rectal and intravenous HIV-1 transmission in humanized BLT mice.

    Directory of Open Access Journals (Sweden)

    Paul W Denton

    Full Text Available Successful antiretroviral pre-exposure prophylaxis (PrEP for mucosal and intravenous HIV-1 transmission could reduce new infections among targeted high-risk populations including discordant couples, injection drug users, high-risk women and men who have sex with men. Targeted antiretroviral PrEP could be particularly effective at slowing the spread of HIV-1 if a single antiretroviral combination were found to be broadly protective across multiple routes of transmission. Therefore, we designed our in vivo preclinical study to systematically investigate whether rectal and intravenous HIV-1 transmission can be blocked by antiretrovirals administered systemically prior to HIV-1 exposure. We performed these studies using a highly relevant in vivo model of mucosal HIV-1 transmission, humanized Bone marrow/Liver/Thymus mice (BLT. BLT mice are susceptible to HIV-1 infection via three major physiological routes of viral transmission: vaginal, rectal and intravenous. Our results show that BLT mice given systemic antiretroviral PrEP are efficiently protected from HIV-1 infection regardless of the route of exposure. Specifically, systemic antiretroviral PrEP with emtricitabine and tenofovir disoproxil fumarate prevented both rectal (Chi square = 8.6, df = 1, p = 0.003 and intravenous (Chi square = 13, df = 1, p = 0.0003 HIV-1 transmission. Our results indicate that antiretroviral PrEP has the potential to be broadly effective at preventing new rectal or intravenous HIV transmissions in targeted high risk individuals. These in vivo preclinical findings provide strong experimental evidence supporting the potential clinical implementation of antiretroviral based pre-exposure prophylactic measures to prevent the spread of HIV/AIDS.

  5. Down hole transmission system

    Science.gov (United States)

    Hall, David R.; Hall, Jr., H. Tracy

    2007-07-24

    A transmission system in a downhole component comprises a data transmission element in both ends of the downhole component. Each data transmission element houses an electrically conducting coil in a MCEI circular trough. The electrically conducting coil comprises at least two generally fractional loops. In the preferred embodiment, the transmission elements are connected by an electrical conductor. Preferably, the electrical conductor is a coaxial cable. Preferably, the MCEI trough comprises ferrite. In the preferred embodiment, the fractional loops are connected by a connecting cable. In one aspect of the present invention, the connecting cable is a pair of twisted wires. In one embodiment the connecting cable is a shielded pair of twisted wires. In another aspect of the present invention, the connecting cable is a coaxial cable. The connecting cable may be disposed outside of the MCEI circular trough.

  6. Understanding land administration systems

    DEFF Research Database (Denmark)

    P. Williamson, Ian; Enemark, Stig; Wallace, Judy

    2008-01-01

    This paper introduces basic land administration theory and highlights four key concepts that are fundamental to understanding modern land administration systems. Readers may recall the first part of the paper in October issue of Coordinates. Here is the concluding part that focuses on the changing...... role of ownership and the role of land markets. Udgivelsesdato: November...

  7. Pro Python System Administration

    CERN Document Server

    Sileika, R

    2010-01-01

    As time goes on, system administrators are presented with increasingly complicated challenges. In the early days, a team of engineers might have had to look after one or two systems. These days, one engineer can administer hundreds or thousands of systems. System administrators are gradually replacing their tools with more advanced and flexible ones. One of the choices is Python. Structurally, Python is a modern, high-level language with a very clean syntax. Python comes with many built-in libraries that can make automation tasks easier. It also has extensive set of third-party libraries and a

  8. Linux System Administration

    CERN Document Server

    Adelstein, Tom

    2007-01-01

    If you're an experienced system administrator looking to acquire Linux skills, or a seasoned Linux user facing a new challenge, Linux System Administration offers practical knowledge for managing a complete range of Linux systems and servers. The book summarizes the steps you need to build everything from standalone SOHO hubs, web servers, and LAN servers to load-balanced clusters and servers consolidated through virtualization. Along the way, you'll learn about all of the tools you need to set up and maintain these working environments. Linux is now a standard corporate platform with user

  9. NB Power Transmission system

    Energy Technology Data Exchange (ETDEWEB)

    Williamson, J. [NB Power Transmission, Fredericton, NB (Canada)

    2006-07-01

    The NB Power Transmission System operates 6700 km of transmission lines having voltages of 69 kV, 138 kV, 230 kV, and 345 kV. The history of lightning protection on this transmission system was presented. Lightning protection with shield wires has been applied selectively on the 69 kV and 138 kV lines and has been applied to all lines in the 230 kV and 345 kV range. Beginning in 2000, line arresters were installed on selected 69 kV and 138 kV lines. It was noted that although overhead shield wires are commonly installed to capture lightning strikes and shield the conductors, problems can occur if the electrical flashover of insulators result in a line to ground fault. Good grounding is needed to ensure that lightning enters the ground from the tower. The new approach is to install line arresters on structures without overhead shield wires. Line arresters are surge arresters applied in parallel with the insulator string. This new line arrester technology was tested by installing nearly 1200 arresters in the Saint John area. This paper described the reasons for choosing line arresters over shield wires and presented the methods of installation. The problems and failure rates of the installed line arresters were presented along with solutions, including solutions to protect lines against lightning in areas with heavy icing. Recommendations for future research into the use, application and development of line arresters were also presented. tabs., figs.

  10. Understanding land administration systems

    DEFF Research Database (Denmark)

    P. Williamson, Ian; Enemark, Stig; Wallace, Judy

    2008-01-01

    in contributing to sustainable development, thirdly the changing nature of ownership and the role of land markets, and lastly a land management vision that promotes land administration in support of sustainable development and spatial enablement of society. We present here the first part of the paper. The second...... part focuses on the changing  role of ownership and the role of land markets, and a land management vision will be published in November issue of Coordinates. Udgivelsesdato: Oktober......This paper introduces basic land administration theory and highlights four key concepts that are fundamental to understanding modern land administration systems - firstly the land management paradigm and its influence on the land administration framework, secondly the role that the cadastre plays...

  11. Land Administration Systems

    DEFF Research Database (Denmark)

    Enemark, Stig

    2014-01-01

    are the rights inherent to all human beings without discrimination. The “constitution” of human rights is the Universal Declaration of Human Rights (UN, 1948) stating the universal rights of human beings based on the principle of respect for the individual – rights that can be enjoyed by everyone simple because...... and that every country and jurisdiction needs to ensure that efficient and effective land administration mechanisms are in place to pursue this interaction. Land administration systems should embed a human rights perspective when managing rights, restrictions and responsibilities in land. This, in turn, imposes...

  12. ATLAS TDAQ System Administration:

    CERN Document Server

    Lee, Christopher Jon; The ATLAS collaboration; Bogdanchikov, Alexander; Ballestrero, Sergio; Contescu, Alexandru Cristian; Dubrov, Sergei; Fazio, Daniel; Korol, Aleksandr; Scannicchio, Diana; Twomey, Matthew Shaun; Voronkov, Artem

    2015-01-01

    The ATLAS Trigger and Data Acquisition (TDAQ) system is responsible for the online processing of live data, streaming from the ATLAS experiment at the Large Hadron Collider (LHC) at CERN. The online farm is composed of ̃3000 servers, processing the data readout from ̃100 million detector channels through multiple trigger levels. During the two years of the first Long Shutdown (LS1) there has been a tremendous amount of work done by the ATLAS TDAQ System Administrators, implementing numerous new software applications, upgrading the OS and the hardware, changing some design philosophies and exploiting the High Level Trigger farm with different purposes. During the data taking only critical security updates are applied and broken hardware is replaced to ensure a stable operational environment. The LS1 provided an excellent opportunity to look into new technologies and applications that would help to improve and streamline the daily tasks of not only the System Administrators, but also of the scientists who wil...

  13. 78 FR 65641 - Recommendation From the Western Area Power Administration To Pursue Regional Transmission...

    Science.gov (United States)

    2013-11-01

    ... Transmission Organization Membership AGENCY: Western Area Power Administration, DOE. ACTION: Notice of Western Area Power Administration Recommendation to Pursue Regional Transmission Organization Membership... formal negotiations with the Southwest Power Pool (SPP), a Regional Transmission Organization...

  14. RBAC Administration in Distributed Systems

    NARCIS (Netherlands)

    Dekker, M.A.C.; Crampton, J.; Etalle, S.

    2007-01-01

    Despite a large body of literature on the administration of RBAC policies in centralized systems, the problem of the administration of a distributed system has hardly been addressed. We present a formal system for modelling a distributed RBAC system and its administration. We define two basic requir

  15. Centos system administration essentials

    CERN Document Server

    Mallett, Andrew

    2014-01-01

    If you are a Linux administrator who is looking to gain knowledge that differentiates yourself from the crowd, then this is the book for you. Beginners who have a keen interest to learn more about Linux administration will also progress quickly with this resourceful learning guide.

  16. Hybrid-Vehicle Transmission System

    Science.gov (United States)

    Lupo, G.; Dotti, G.

    1985-01-01

    Continuously-variable transmission system for hybrid vehicles couples internal-combustion engine and electric motor section, either individually or in parallel, to power vehicle wheels during steering and braking.

  17. Harmonics in transmission power systems

    DEFF Research Database (Denmark)

    Wiechowski, Wojciech Tomasz

    in transmission power systems" was formulated. In this project, the entire 400 kV and 150 kV western transmission network of Energinet.dk is modelled using the simulation software DIgSILENT PowerFactory. A fundamental frequency load-flow model is used as a basis that is to be extended. The model is sought......, provided that background harmonic distortion, and the network configuration, are not changing during the measurement. It is shown that switching of a shunt linear power system component can result in variation of the harmonic levels that can be measured and used to verify the harmonic model of the network......, in order to determine which power system component, when switched, results in the largest change in harmonic levels, some initial harmonic simulations, using the created harmonic model of Energinet.dk transmission network, are performed. The criterion is that the measuring equipment shall not be installed...

  18. CONTRACT ADMINISTRATIVE TRACKING SYSTEM (CATS)

    Science.gov (United States)

    The Contract Administrative Tracking System (CATS) was developed in response to an ORD NHEERL, Mid-Continent Ecology Division (MED)-recognized need for an automated tracking and retrieval system for Cost Reimbursable Level of Effort (CR/LOE) Contracts. CATS is an Oracle-based app...

  19. Transmission system planning in Ontario

    Energy Technology Data Exchange (ETDEWEB)

    Barrie, D.; Macedo, F.X.; Mcconnach, J.S. [Ontario Hydro, Toronto, ON (Canada)

    1994-12-31

    In recent years, new and modified approaches to planning the large transmission system that serves the province of Ontario, Canada, have been necessary to accommodate the rapidly changing planning environment including slower uncertain growth, ageing of facilities, integration of demand side management and non utility generation options, increased competitiveness, increased financial stresses and affordable constraints. This paper describes some of the new and modified approaches and tools that have been adopted or are being developed by Ontario Hydro to cope with this changing environment. (author) 9 refs., 4 figs.

  20. VIDEO TRANSMISSION SYSTEM IN ITV APPLICATION

    Institute of Scientific and Technical Information of China (English)

    WangYancai; WangQunwei; WangZhaohui

    1996-01-01

    The transmission characteristics of video transmission mediums,coaxial cable and optical fiber ,are discussed in the paper. The formulas for frequency bandwidthare given to evaluate the video transmission distance. For typical video transmissionsystems with BB/IM and PFM/IM using optical fiber as the channel, expressions andcalculating results for both SIN and sensitivity are given. Finally. the principle for selecting different type of transmission systems according to transmission distances of the industrial TV is presented.

  1. 49 CFR 191.13 - Distribution systems reporting transmission pipelines; transmission or gathering systems...

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Distribution systems reporting transmission pipelines; transmission or gathering systems reporting distribution pipelines. 191.13 Section 191.13... Distribution systems reporting transmission pipelines; transmission or gathering systems reporting...

  2. Fractional Frequency Transmission System and Its Applications

    Institute of Scientific and Technical Information of China (English)

    WANG Xifan; WANG Xiuli; TENG Yufei

    2012-01-01

    In 1994, we proposed transmission approach, the a novel fractional electricity frequency transmission system (FFTS), which uses lower frequency (50/3 Hz) to reduce the electrical length of AC power lines and thus obviously increases transmission capacity. The system is especially suitable to transmit remote renewable power such as hydro power and wind power.

  3. Game Changing Usage of High-Voltage Power Transmission Systems as Extremely Large Antennas for Space Physical and Geophysical Remote Imaging Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Geomagnetic storms drive geomagnetically induced currents (GIC) in high-voltage power transmission systems worldwide. GIC distribution in the transmission system is...

  4. RESEARCH OF DYNAMIC CHARACTERIATIC FOR TRANSMISSION SYSTEM

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The kinetic precision of transmission chain is a key problem in the research of gear cutting machine transmission system.The traditional point of view is to consider the transmission chain as a geometrical meshing system,thus it is deemed that the kinetic precision of the transmission chain only depends on the manufacturing and assembly errors of its transmission parts.But further research reveals that the kinetic precision of transmission system is closely related with the system dynamic effects.Therefore,from the dynamic point of view,it is discerned that not only deems the transmission chain as a geometrical meshing system but also considers it as a dynamic system performing with torsional vibration.On the basis of analyses and processes of measuring data of samples from tests of cutting machine's kinetic precision of transmission chain,the results represent that the influences of dynamic characteristics of the transmission system on its kinetic precision is non-negligible.Experimental methods for discerning the transfer function of torsional vibration of gear transmission system and experimental results have been given.

  5. International Conference on Harmonisation; Electronic Transmission of Postmarket Individual Case Safety Reports for Drugs and Biologics, Excluding Vaccines; Availability of Food and Drug Administration Regional Implementation Specifications for ICH E2B(R3) Reporting to the Food and Drug Administration Adverse Event Reporting System. Notice of Availability.

    Science.gov (United States)

    2016-06-23

    The Food and Drug Administration (FDA) is announcing the availability of its FDA Adverse Event Reporting System (FAERS) Regional Implementation Specifications for the International Conference on Harmonisation (ICH) E2B(R3) Specification. FDA is making this technical specifications document available to assist interested parties in electronically submitting individual case safety reports (ICSRs) (and ICSR attachments) to the Center for Drug Evaluation and Research (CDER) and the Center for Biologics Evaluation and Research (CBER). This document, entitled "FDA Regional Implementation Specifications for ICH E2B(R3) Implementation: Postmarket Submission of Individual Case Safety Reports (ICSRs) for Drugs and Biologics, Excluding Vaccines" supplements the "E2B(R3) Electronic Transmission of Individual Case Safety Reports (ICSRs) Implementation Guide--Data Elements and Message Specification" final guidance for industry and describes FDA's technical approach for receiving ICSRs, for incorporating regionally controlled terminology, and for adding region-specific data elements when reporting to FAERS.

  6. Bonneville, Power Administration Timing System

    Science.gov (United States)

    Martin, Kenneth E.

    1996-01-01

    Time is an integral part of the Bonneville Power Administration's (BPA) operational systems. Generation and power transfers are planned in advance. Utilities coordinate with each other by making these adjustments on a timed schedule. Price varies with demand, so billing is based on time. Outages for maintenance are scheduled to assure they do not interrupt reliable power delivery. Disturbance records are aligned with recorded timetags for analysis and comparison with related information. Advanced applications like traveling wave fault location and real-time phase measurement require continuous timing with high precision. Most of BPA is served by a Central Time System (CTS) at the Dittmer Control Center near Portland, OR. This system keeps time locally and supplies time to both the control center systems and field locations via a microwave signal. It is kept synchronized to national standard time and coordinated with interconnected utilities. It is the official BPA time. Powwer system control and operation is described, followed by a description of BPA timing systems including CTS, the Fault Location Acquisition Reporter, time dissemination, and phasor measurements. References are provided for further reading.

  7. TWRS information locator database system administrator`s manual

    Energy Technology Data Exchange (ETDEWEB)

    Knutson, B.J., Westinghouse Hanford

    1996-09-13

    This document is a guide for use by the Tank Waste Remediation System (TWRS) Information Locator Database (ILD) System Administrator. The TWRS ILD System is an inventory of information used in the TWRS Systems Engineering process to represent the TWRS Technical Baseline. The inventory is maintained in the form of a relational database developed in Paradox 4.5.

  8. THE ADMINISTRATIVE SYSTEM IN FRANCE

    Directory of Open Access Journals (Sweden)

    DOINA POPESCU

    2012-05-01

    Full Text Available According to the Constitution promulgated on the 6th of October 1958, with the latest amendments made in 1999, France is a presidential republic. The three authority branches are broadly represented in the French administration: the judicial branch – French courts of law are divided into: judicial courts and administrative courts. Judicial courts are under the supreme authority of the Court of Cassation with jurisdiction to cancel judgments passed courts on inferior hierarchy levels and plays a central role in the appropriate performance of the activity. The legislative body - normally, the legislation is voted by Parliament. French Parliament is comprised of two chambers: the National Assembly and the Senate. The National Assembly is elected for five years by way of direct universal voting. The Senate is elected by way of indirect universal voting by the electoral group. The election system is based on rules contained in the Election Code. The executive authority is divided between the President of the Republic and the Prime Minister. The President of the Republic makes the appointments for civil and military positions located at the highest state level. The Council of Ministers is responsible for appointing the positions of state councillors, prefect and public administration director. The central government is headed by the Prime Minister. Regional authorities – the regions are free territories administered by elected Councils. As far as the metropolitan part of France is concerned, there are 22 such territories, to which are added other four districts / counties which are located out of borders. The region’s Prefect represents the state and is empowered to deploy legal actions in order to protect the state’s best interest. County authorities – there are currently 96 de districts, to which four other territories located out of borders are added, as well as the territorial communities of Mayoutte and St-Pierre et Miquelon. There are

  9. Repeated administration of imipramine modifies GABAergic transmission in rat frontal cortex.

    Science.gov (United States)

    Wabno, Joanna; Hess, Grzegorz

    2013-05-01

    Alterations in the functions of brain gamma-aminobutyric acid (GABA) inhibitory system and a distortion in the balance between excitatory and inhibitory synaptic transmission have been hypothesized to be possible causes of mood disorders. Experimental evidence points to modifications of GABAergic transmission as a result of prolonged treatment with antidepressant drugs, however, the influence of the tricyclic antidepressant imipramine on inhibitory synaptic transmission in the rat cerebral cortex has not yet been investigated. Therefore, in the present study the effects of single and repeated administration of imipramine were evaluated ex vivo in slices of the rat frontal cortex using electrophysiological approach. In slices prepared 2 days after the last drug administration from animals receiving imipramine for 14 days (dose 10 mg/kg p.o., twice daily) the mean frequency of spontaneous inhibitory postsynaptic currents (sIPSCs) recorded from layer II/III pyramidal neurons was decreased, while the mean amplitude of sIPSCs was increased. These effects were absent in slices obtained from rats which received imipramine once. Application of N,N'-dibenzhydrylethane-1,2-diamine dihydrochloride (AMN 082), a selective mGluR7 allosteric agonist, to the slice incubation medium resulted in a decrease in the mean frequency of sIPSCs in preparations obtained from repeated imipramine-treated animals, in contrast to slices originating from control rats where no AMN 082-induced effects were observed. Repeated imipramine treatment reduced protein density levels of the three tested GABAA receptor subunits: α 1, β 2 and γ 2. These data indicate that repeated treatment of normal rats with imipramine results in a modification of the release mechanism of GABA from presynaptic terminals and its modulation by mGluR7 receptors as well as in an alteration in GABAA receptor subunit protein levels in the rat cerebral cortex.

  10. Gear Transmission Error Measurement System Made Operational

    Science.gov (United States)

    Oswald, Fred B.

    2002-01-01

    A system directly measuring the transmission error between the meshing spur or helical gears was installed at the NASA Glenn Research Center and made operational in August 2001. This system employs light beams directed by lenses and prisms through gratings mounted on the two gear shafts. The amount of light that passes through both gratings is directly proportional to the transmission error of the gears. The device is capable of resolution better than 0.1 mm (one thousandth the thickness of a human hair). The measured transmission error can be displayed in a "map" that shows how the transmission error varies with the gear rotation or it can be converted to spectra to show the components at the meshing frequencies. Accurate transmission error data will help researchers better understand the mechanisms that cause gear noise and vibration and will lead to The Design Unit at the University of Newcastle in England specifically designed the new system for NASA. It is the only device in the United States that can measure dynamic transmission error at high rotational speeds. The new system will be used to develop new techniques to reduce dynamic transmission error along with the resulting noise and vibration of aeronautical transmissions.

  11. THE ADMINISTRATIVE SYSTEM IN FRANCE

    OpenAIRE

    2012-01-01

    According to the Constitution promulgated on the 6th of October 1958, with the latest amendments made in 1999, France is a presidential republic. The three authority branches are broadly represented in the French administration: the judicial branch – French courts of law are divided into: judicial courts and administrative courts. Judicial courts are under the supreme authority of the Court of Cassation with jurisdiction to cancel judgments passed courts on inferior hierarchy levels and plays...

  12. Methods, apparatus, and systems for monitoring transmission systems

    Energy Technology Data Exchange (ETDEWEB)

    Polk, Robert E; Svoboda, John M.; West, Phillip B.; Heath, Gail L.; Scott, Clark L.

    2016-07-19

    A sensing platform for monitoring a transmission system, and method therefor, may include a sensor that senses one or more conditions relating to a condition of the transmission system and/or the condition of an environment around the transmission system. A control system operatively associated with the sensor produces output data based on an output signal produced by the sensor. A transmitter operatively associated with the control system transmits the output data from the control system.

  13. APEnet+ 34 Gbps data transmission system and custom transmission logic

    Science.gov (United States)

    Ammendola, R.; Biagioni, A.; Frezza, O.; Lonardo, A.; Lo Cicero, F.; Paolucci, P. S.; Rossetti, D.; Simula, F.; Tosoratto, L.; Vicini, P.

    2013-12-01

    APEnet+ is a point-to-point, low-latency, 3D-torus network controller integrated in a PCIe Gen2 board based on the Altera Stratix IV FPGA. We characterize the transmission system (embedded transceivers driving external QSFP+ modules) analyzing signal integrity, throughput, latency, BER and jitter at different data rates up to 34 Gbps. We estimate the efficiency of a custom logic able to sustain 2.6 GB/s per link with an FPGA on-chip memory footprint of 40 KB, providing deadlock-free routing and systemic awareness of faults. Finally, we show the preliminary results obtained with the embedded transceivers of a next-generation FPGA and outline some ideas to increase the performance with the same FPGA memory footprint.

  14. Transmission assessment surveys (TAS) to define endpoints for lymphatic filariasis mass drug administration

    DEFF Research Database (Denmark)

    Chu, Brian K.; Deming, Michael; Biritwum, Nana-Kwadwo

    2013-01-01

    Lymphatic filariasis (LF) is targeted for global elimination through treatment of entire at-risk populations with repeated annual mass drug administration (MDA). Essential for program success is defining and confirming the appropriate endpoint for MDA when transmission is presumed to have reached...

  15. Economics Of Optical Fibre Transmission Systems

    Science.gov (United States)

    Murray, W. J.

    1983-08-01

    Optical fibre as a telecommunication transmission medium has become one of the most significant developments so far of the digital era. A major contributory factor to the availability of optical fibre transmission systems has been the outstanding progress in the technology of manufacturing high quality glass fibre having relatively low attenuation and broad bandwidths. This and other achievements has enabled manufacturers in the United Kingdom to develop a range of optical fibre cables and transmission equipment for operation over short and long distances at the CCITT recommended digital hierarchical rates of 2, 8, 34 and 140Mbit/s which have been adopted by British Telecom (BT) for modernisation to an all digital transmission network. These optical fibre systems are now becoming increasingly price and performance competitive with conventional technology in many parts of telecommunications networks. In the British Telecom (BT) network the 140Mbit/s optical fibre systems are now economically competitive with equivalent systems on coaxial cable and microwave radio. The economics of 8 and 34Mbit/s systems are not yet sufficiently attractive, compared with 2Mbit/s digital line systems on pair type copper cables, for large scale use in rural and local distribution networks and are presently only justified on cost in and around large cities. As system costs decrease large applications are predicted particularly in support of future high speed data, cable television and visual information services.

  16. New Gear Transmission Error Measurement System Designed

    Science.gov (United States)

    Oswald, Fred B.

    2001-01-01

    The prime source of vibration and noise in a gear system is the transmission error between the meshing gears. Transmission error is caused by manufacturing inaccuracy, mounting errors, and elastic deflections under load. Gear designers often attempt to compensate for transmission error by modifying gear teeth. This is done traditionally by a rough "rule of thumb" or more recently under the guidance of an analytical code. In order for a designer to have confidence in a code, the code must be validated through experiment. NASA Glenn Research Center contracted with the Design Unit of the University of Newcastle in England for a system to measure the transmission error of spur and helical test gears in the NASA Gear Noise Rig. The new system measures transmission error optically by means of light beams directed by lenses and prisms through gratings mounted on the gear shafts. The amount of light that passes through both gratings is directly proportional to the transmission error of the gears. A photodetector circuit converts the light to an analog electrical signal. To increase accuracy and reduce "noise" due to transverse vibration, there are parallel light paths at the top and bottom of the gears. The two signals are subtracted via differential amplifiers in the electronics package. The output of the system is 40 mV/mm, giving a resolution in the time domain of better than 0.1 mm, and discrimination in the frequency domain of better than 0.01 mm. The new system will be used to validate gear analytical codes and to investigate mechanisms that produce vibration and noise in parallel axis gears.

  17. Ivermectin mass drug administration to humans disrupts malaria parasite transmission in Senegalese villages.

    Science.gov (United States)

    Kobylinski, Kevin C; Sylla, Massamba; Chapman, Phillip L; Sarr, Moussa D; Foy, Brian D

    2011-07-01

    Ivermectin mass drug administration (MDA) to humans is used to control onchocerciasis and lymphatic filariasis. Recent field studies have shown an added killing effect of ivermectin MDA against malaria vectors. We report that ivermectin MDA reduced the proportion of Plasmodium falciparum infectious Anopheles gambiae sensu stricto (s.s.) in treated villages in southeastern Senegal. Ivermectin MDA is a different delivery method and has a different mode of action from current malaria control agents. It could be a powerful and synergistic new tool to reduce malaria transmission in regions with epidemic or seasonal malaria transmission, and the prevalence and intensity of neglected tropical diseases.

  18. International Benchmarking of Electricity Transmission System Operators

    DEFF Research Database (Denmark)

    Agrell, Per J.; Bogetoft, Peter

    2014-01-01

    Electricity transmission system operators (TSO) in Europe are increasing subject to high-powered performance-based regulation, such as revenue-cap regimes. The determination of the parameters in such regimes is challenging for national regulatory authorities (NRA), since there is normally a single...

  19. Benchmarking European Gas Transmission System Operators

    DEFF Research Database (Denmark)

    Agrell, Per J.; Bogetoft, Peter; Trinkner, Urs

    This is the final report for the pan-European efficiency benchmarking of gas transmission system operations commissioned by the Netherlands Authority for Consumers and Markets (ACM), Den Haag, on behalf of the Council of European Energy Regulators (CEER) under the supervision of the authors....

  20. Wireless Transmission System for Vehicle Inspection Data

    Institute of Scientific and Technical Information of China (English)

    LIU Yuan; MIAO Chang-yun

    2008-01-01

    Based on general packet radio service(GPRS) and TCP/IP protocol, a wireless transmission system of vehicle inspection data is designed. Basic structure and work theory are expounded. SIM300 designed by SIMCOM is used for client GPRS communication module. Using Winsock control of visual basic(VB), the client and server communication has been accomplished. By means of a client and server communications software, the remote wireless transmission of vehicle inspection data has been accomplished also. The server management software has been developed by using Microsoft SQL Server 2000 and VB6.0. Functions of software include import, inquiry, export and maintenance of test data.

  1. Debian 7 system administration best practices

    CERN Document Server

    Pollei, Rich

    2013-01-01

    A step-by-step, example-based guide to learning how to install and administer the Debian Linux distribution.Debian 7: System Administration Best Practices is for users and administrators who are new to Debian, or for seasoned administrators who are switching to Debian from another Linux distribution. A basic knowledge of Linux or UNIX systems is useful, but not strictly required. Since the book is a high level guide, the reader should be willing to go to the referenced material for further details and practical examples.

  2. Python for Unix and Linux system administration

    CERN Document Server

    Gift, Noah

    2007-01-01

    Python is an ideal language for solving problems, especially in Linux and Unix networks. With this pragmatic book, administrators can review various tasks that often occur in the management of these systems, and learn how Python can provide a more efficient and less painful way to handle them. Each chapter in Python for Unix and Linux System Administration presents a particular administrative issue, such as concurrency or data backup, and presents Python solutions through hands-on examples. Once you finish this book, you'll be able to develop your own set of command-line utilities with Pytho

  3. System Administrator for LCS Development Sets

    Science.gov (United States)

    Garcia, Aaron

    2013-01-01

    The Spaceport Command and Control System Project is creating a Checkout and Control System that will eventually launch the next generation of vehicles from Kennedy Space Center. KSC has a large set of Development and Operational equipment already deployed in several facilities, including the Launch Control Center, which requires support. The position of System Administrator will complete tasks across multiple platforms (Linux/Windows), many of them virtual. The Hardware Branch of the Control and Data Systems Division at the Kennedy Space Center uses system administrators for a variety of tasks. The position of system administrator comes with many responsibilities which include maintaining computer systems, repair or set up hardware, install software, create backups and recover drive images are a sample of jobs which one must complete. Other duties may include working with clients in person or over the phone and resolving their computer system needs. Training is a major part of learning how an organization functions and operates. Taking that into consideration, NASA is no exception. Training on how to better protect the NASA computer infrastructure will be a topic to learn, followed by NASA work polices. Attending meetings and discussing progress will be expected. A system administrator will have an account with root access. Root access gives a user full access to a computer system and or network. System admins can remove critical system files and recover files using a tape backup. Problem solving will be an important skill to develop in order to complete the many tasks.

  4. Transmission techniques for 4G systems

    CERN Document Server

    Da Silva, Mario Marques

    2012-01-01

    Fourth Generation (4G) wireless communication systems support current and emergent multimedia services such as mobile TV, social networks and gaming, high-definition TV, video teleconferencing, and messaging services. These systems feature the All-over-IP concept and boast improved quality of service. Several important R&D activities are currently under way in the field of wireless communications for 4G systems, but the coverage is widespread in the literature. Transmission Techniques for 4G Systems presents a compilation of the latest developments in the field of wireless communications for 4

  5. Software Architecture Patterns for System Administration Support

    NARCIS (Netherlands)

    Bijvank, Ronald; Wiersema, Wiebe; Köppe, Christian

    2013-01-01

    Many quality aspects of software systems are addressed in the existing literature on software architecture patterns. But the aspect of system administration seems to be a bit overlooked, even though it is an important aspect too. In this work we present three software architecture patterns that, whe

  6. Switching in electrical transmission and distribution systems

    CERN Document Server

    Smeets, René; Kapetanovic, Mirsad; Peelo, David F; Janssen, Anton

    2014-01-01

    Switching in Electrical Transmission and Distribution Systems presents the issues and technological solutions associated with switching in power systems, from medium to ultra-high voltage. The book systematically discusses the electrical aspects of switching, details the way load and fault currents are interrupted, the impact of fault currents, and compares switching equipment in particular circuit-breakers. The authors also explain all examples of practical switching phenomena by examining real measurements from switching tests. Other highlights include: up to date commentary on new develo

  7. Flexible AC transmission systems modelling and control

    CERN Document Server

    Zhang, Xiao-Ping; Pal, Bikash

    2012-01-01

    The extended and revised second edition of this successful monograph presents advanced modeling, analysis and control techniques of Flexible AC Transmission Systems (FACTS). The book covers comprehensively a range of power-system control problems: from steady-state voltage and power flow control, to voltage and reactive power control, to voltage stability control, to small signal stability control using FACTS controllers. In the six years since the first edition of the book has been published research on the FACTS has continued to flourish while renewable energy has developed into a mature and

  8. Network video transmission system based on SOPC

    Science.gov (United States)

    Zhang, Zhengbing; Deng, Huiping; Xia, Zhenhua

    2008-03-01

    Video systems have been widely used in many fields such as conferences, public security, military affairs and medical treatment. With the rapid development of FPGA, SOPC has been paid great attentions in the area of image and video processing in recent years. A network video transmission system based on SOPC is proposed in this paper for the purpose of video acquisition, video encoding and network transmission. The hardware platform utilized to design the system is an SOPC board of model Altera's DE2, which includes an FPGA chip of model EP2C35F672C6, an Ethernet controller and a video I/O interface. An IP core, known as Nios II embedded processor, is used as the CPU of the system. In addition, a hardware module for format conversion of video data, and another module to realize Motion-JPEG have been designed with Verilog HDL. These two modules are attached to the Nios II processor as peripheral equipments through the Avalon bus. Simulation results show that these two modules work as expected. Uclinux including TCP/IP protocol as well as the driver of Ethernet controller is chosen as the embedded operating system and an application program scheme is proposed.

  9. 47 CFR 73.6023 - Distributed transmission systems.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Distributed transmission systems. 73.6023... distributed transmission system. ... RADIO BROADCAST SERVICES Class A Television Broadcast Stations § 73.6023 Distributed...

  10. EFFICIENT IMAGE TRANSMISSION SCHEME IN FMT SYSTEM

    Institute of Scientific and Technical Information of China (English)

    Qi Zhongrui; Gao Zhenming

    2005-01-01

    An efficient image transmission scheme is proposed based on byte partition and adaptive sub-channel distribution technique in Filtered MultiTone (FMT) system over frequency selective slow fading channel. According to the simulation results and analysis of a typical image with matlab, improvement in Peak Signal to Noise Ratio (PSNR) of the received image and low complexity for equalization is demonstrated remarkably. Comparing with no adaptive and no actual channel equalization scheme, the proposed scheme saves over 6 dB when PSNR=40 dB.

  11. International Benchmarking of Electricity Transmission System Operators

    DEFF Research Database (Denmark)

    Agrell, Per J.; Bogetoft, Peter

    2014-01-01

    Electricity transmission system operators (TSO) in Europe are increasing subject to high-powered performance-based regulation, such as revenue-cap regimes. The determination of the parameters in such regimes is challenging for national regulatory authorities (NRA), since there is normally a single...... TSO operating in each jurisdiction. The solution for European regulators has been found in international regulatory benchmarking, organized in collaboration with the Council of European Energy Regulators (CEER) in 2008 and 2012 for 22 and 23 TSOs, respectively. The frontier study provides static cost...

  12. Alternate Routes of Administration among Prescription Opioid Misusers and Associations with Sexual HIV Transmission Risk Behaviors.

    Science.gov (United States)

    Buttram, Mance E; Kurtz, Steven P

    2016-01-01

    Literature suggests that young adult prescription opioid misusers who are using alternate routes of administration (e.g., snorting, injecting) may be engaging in sexual and non-sexual HIV risk behaviors. This study examines demographics, substance use, sexual risk behavior, and health and social problems associated with alternate routes of administration of prescription opioids among a sample of young adult prescription opioid misusers. Data are drawn from baseline assessments from a behavioral intervention trial. Eligible participants were ages 18-39, and reported recent (past 90 days) heterosexual sex, and recent and regular substance use and attendance at large, recognized local nightclubs. The analyses include 446 racially/ethnically diverse participants. In bivariate regression models, compared to those who did not, participants reporting alternate routes of administration (n = 209) were more likely to be White (p routes of administration of prescription opioids are associated with sexual HIV transmission risk behaviors. Early prevention and intervention efforts that address sexual and non-sexual HIV risk behaviors are warranted.

  13. 47 CFR 73.626 - DTV distributed transmission systems.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false DTV distributed transmission systems. 73.626... RADIO BROADCAST SERVICES Television Broadcast Stations § 73.626 DTV distributed transmission systems. (a... distributed transmission system (DTS). Except as expressly provided in this section, DTV stations operating...

  14. CLARA: an integrated clinical research administration system.

    Science.gov (United States)

    Bian, Jiang; Xie, Mengjun; Hogan, William; Hutchins, Laura; Topaloglu, Umit; Lane, Cheryl; Holland, Jennifer; Wells, Thomas

    2014-10-01

    Administration of human subject research is complex, involving not only the institutional review board but also many other regulatory and compliance entities within a research enterprise. Its efficiency has a direct and substantial impact on the conduct and management of clinical research. In this paper, we report on the Clinical Research Administration (CLARA) platform developed at the University of Arkansas for Medical Sciences. CLARA is a comprehensive web-based system that can streamline research administrative tasks such as submissions, reviews, and approval processes for both investigators and different review committees on a single integrated platform. CLARA not only helps investigators to meet regulatory requirements but also provides tools for managing other clinical research activities including budgeting, contracting, and participant schedule planning.

  15. ATLAS TDAQ System Administration: Master of Puppets

    CERN Document Server

    Lee, Christopher; The ATLAS collaboration

    2016-01-01

    Within the ATLAS detector, the Trigger and Data Acquisition system is responsible for the online processing of data streamed from the detector during collisions at the Large Hadron Collider at CERN. The online farm is comprised of ~4000 servers processing the data read out from ~100 million detector channels through multiple trigger levels. Configuring of these servers is not an easy task, especially since the detector itself is made up of multiple different sub-detectors, each with their own particular requirements. The previous method of configuring these servers, using Quattor and a hierarchical scripts system was cumbersome and restrictive. A better, unified system was therefore required to simplify the tasks of the TDAQ Systems Administrators, for both the local and net booted systems, and to be able to fulfil the requirements of TDAQ, Detector Control Systems and the sub-detectors groups. Various configuration management systems were evaluated, though in the end, Puppet was chosen as the application of ...

  16. Multi-transmission-line-beam interactive system

    Energy Technology Data Exchange (ETDEWEB)

    Figotin, Alexander; Reyes, Guillermo [Department of Mathematics, University of California at Irvine, Irvine, California 92697-3875 (United States)

    2013-11-15

    We construct here a Lagrangian field formulation for a system consisting of an electron beam interacting with a slow-wave structure modeled by a possibly non-uniform multiple transmission line (MTL). In the case of a single line we recover the linear model of a traveling wave tube due to J. R. Pierce. Since a properly chosen MTL can approximate a real waveguide structure with any desired accuracy, the proposed model can be used in particular for design optimization. Furthermore, the Lagrangian formulation provides: (i) a clear identification of the mathematical source of amplification, (ii) exact expressions for the conserved energy and its flux distributions obtained from the Noether theorem. In the case of uniform MTLs we carry out an exhaustive analysis of eigenmodes and find sharp conditions on the parameters of the system to provide for amplifying regimes.

  17. Flexible AC transmission systems: the state of the art

    Energy Technology Data Exchange (ETDEWEB)

    Edris, Abdel-Aty [Electric Power Research Inst., Palo Alto, CA (United States). Electric Systems Division

    1994-12-31

    Flexible AC transmission systems (FACTS) is a concept promoting the use of power electronic controllers to enhance the controllability and usable capacity of AC transmission. This paper presents the state of the art of FACTS and the status of the current projects for the application of the FACTS controllers in transmission systems. (author) 8 refs., 8 figs.

  18. Combined heuristic with fuzzy system to transmission system expansion planning

    Energy Technology Data Exchange (ETDEWEB)

    Silva Sousa, Aldir; Asada, Eduardo N. [University of Sao Paulo, Sao Carlos School of Engineering, Department of Electrical Engineering Av. Trabalhador Sao-carlense, 400, 13566-590 Sao Carlos, SP (Brazil)

    2011-01-15

    A heuristic algorithm that employs fuzzy logic is proposed to the power system transmission expansion planning problem. The algorithm is based on the divide to conquer strategy, which is controlled by the fuzzy system. The algorithm provides high quality solutions with the use of fuzzy decision making, which is based on nondeterministic criteria to guide the search. The fuzzy system provides a self-adjusting mechanism that eliminates the manual adjustment of parameters to each system being solved. (author)

  19. Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-142- KeelerOregon City #2)

    Energy Technology Data Exchange (ETDEWEB)

    Barndt, Shawn L. [Bonneville Power Administration, Portland, OR (United States)

    2003-04-04

    Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-142- KeelerOregon #2). Bonneville Power Administration proposes to remove vegetation alongside Transmission Right-of-Ways

  20. Insulation systems for superconducting transmission cables

    DEFF Research Database (Denmark)

    Tønnesen, Ole

    1996-01-01

    This paper describes shortly the status of superconducting transmission lines and assesses what impact the recently discovered BSCCO superconductors may have on the design of the cables.Two basically different insulation systems are discussed:1) The room temperature dielectric design, where...... the electrical insulation is placed outside both the superconducting tube and the cryostat. The superconducting tube is cooled by liquid nitrogen which is pumped through the hollow part of the tube.2) The cryogenic dielectric design, where the electrical insulation is placed inside the cryostat and thus is kept...... at temperature near 77 K.The optimal design is determined by a loss evaluation in relation to the power transfer capacity of the cable. Development work in progress on the design and construction of superconducting cables in Denmark is described as an example....

  1. Microfluidic system for transmission electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Ring, Elisabeth A [ORNL; De Jonge, Niels [ORNL

    2010-01-01

    We present a microfluidic system that maintains liquid flow in a specimen chamber for (scanning) transmission electron microscope ((S)TEM) imaging. The specimen chamber consists of two ultra-thin silicon nitride windows supported by silicon microchips. They are placed in a specimen holder that seals the sample from the vacuum in the electron microscope, and incorporates tubing to and from the sample connected to a syringe pump outside the microscope. Using results obtained from fluorescence microscopy of microspheres flowing through the system, an equation to characterize the liquid flow through the system was calibrated. Gold nanoparticles of diameters of 30 and 100 nm moving in liquid were imaged with a 200 kV STEM. It was concluded that despite strong influences from Brownian motion, and sensitivity to small changes in the depth of the bypass channel, the electron microscopy flow data matched the calculated flow speed within an order of magnitude. The system allows for rapid (within a minute) liquid exchange, which can potentially be used, for example, to investigate the response of specimens, e.g., eukaryotic-, or bacterial cells, to certain stimuli.

  2. Contemporary Development Trends in Administrative-Legal Relations in the System of Administrative Justice

    Science.gov (United States)

    Abdikerimova, Aynur A.

    2016-01-01

    The purpose of the study is to determine the main contemporary development trends in administrative-legal relations in the field of administrative justice. In order to examine theoretical and practical issues of modern administrative justice, normative legal acts identifying the relations in the system of administrative justice in the Republic in…

  3. New Comparison of HVDC and HVAC Transmission system

    Directory of Open Access Journals (Sweden)

    Vahid Behravesh

    2012-06-01

    Full Text Available Alternating current (AC is the main driving force in the industries and residential areas, but for the long transmission line (more than 400 miles AC transmission is more expensive than that of direct current (DC. Technically, AC transmission line control is more complicated because of the frequency. DC transmission does not have these limitations, which has led to build long HVDC transmission lines over the last 40 years. HVDC technology made possible to transfer bulk power over long distances. This paper presents a comparative evaluation of HVDC and HVAC transmission systems .

  4. Development of the Field of Flexible AC Transmission Systems (FACTS)

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    @@ Theoretical and technological development of large capacity power electronics and flexible AC transmission systems are one of the most important projects developed by Tsinghua University. The Flexible AC Transmission System (FACTS) technology which uses power electronics to improve the efficiency and quality of the electrical generation, transmission and distribution system is considered to be one of the most significant technological innovations for power systems in the 20th century. The advanced static var generator (ASVG) is a key FACTS device.

  5. An embedded Video Transmission System Based on H.264

    Institute of Scientific and Technical Information of China (English)

    GAO Jing-min; LAN Ya-zhu

    2009-01-01

    In this paper,an embedded Video Transmission System based on H.264 is proposed.In this system,the latest video compression standards-H.264 is used as video codec algorithm,the i.mx27 is used as the center processors of the system,embedded Linux is used as the operating system and RTP/UDP is used as the network transmission protocol.The paper introduces the design way and the frame of the system.The test results of the system show that the proposed system can support good quality transmission of the video information.The parameters with the transmission are D1,720*480,30fps and 4Mbps.In addition,in order to ensure the security of the video information in the transmission,the system provides the encryption to the information in the process of compressing.

  6. Transmission techniques for emergent multicast and broadcast systems

    CERN Document Server

    da Silva, Mario Marques; Dinis, Rui; Souto, Nuno; Silva, Joao Carlos

    2010-01-01

    Describing efficient transmission schemes for broadband wireless systems, Transmission Techniques for Emergent Multicast and Broadcast Systems examines advances in transmission techniques and receiver designs capable of supporting the emergent wireless needs for multimedia broadcast and multicast service (MBMS) requirements. It summarizes the research and development taking place in wireless communications for multimedia MBMS and addresses the means to improved spectral efficiency to allow for increased user bit rate, as well as increased capacity of the digital cellular radio network.The text

  7. MIMO Identical Eigenmode Transmission System (IETS) - A Channel Decomposition Perspective

    CERN Document Server

    Shakir, M Zeeshan

    2010-01-01

    In the past few years considerable attention has been given to the design of Multiple-Input Multiple-Output (MIMO) Eigenmode Transmission Systems (EMTS). This paper presents an in-depth analysis of a new MIMO eigenmode transmission strategy. The non-linear decomposition technique called Geometric Mean Decomposition (GMD) is employed for the formation of eigenmodes over MIMO flatfading channel. Exploiting GMD technique, identical, parallel and independent transmission pipes are created for data transmission at higher rate. The system based on such decomposition technique is referred to as MIMO Identical Eigenmode Transmission System (IETS). The comparative analysis of the MIMO transceiver design exploiting nonlinear and linear decomposition techniques for variable constellation is presented in this paper. The new transmission strategy is tested in combination with the Vertical Bell Labs Layered Space Time (V-BLAST) decoding scheme using different number of antennas on both sides of the communication link. The ...

  8. 47 CFR 73.49 - AM transmission system fencing requirements.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false AM transmission system fencing requirements. 73.49 Section 73.49 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES RADIO BROADCAST SERVICES AM Broadcast Stations § 73.49 AM transmission system fencing...

  9. Optimization of transmission system design based on genetic algorithm

    Directory of Open Access Journals (Sweden)

    Xianbing Chen

    2016-05-01

    Full Text Available Transmission system is a crucial precision mechanism for twin-screw chemi-mechanical pulping equipment. The structure of the system designed by traditional method is not optimal because the structure designed by the traditional methods is easy to fall into the local optimum. To achieve the global optimum, this article applies the genetic algorithm which has grown in recent years in the field of structure optimization. The article uses the volume of transmission system as the objective function to optimize the structure designed by traditional method. Compared to the simulation results, the original structure is not optimal, and the optimized structure is tighter and more reasonable. Based on the optimized results, the transmission shafts in the transmission system are designed and checked, and the parameters of the twin screw are selected and calculated. The article provided an effective method to design the structure of transmission system.

  10. Nonlinear system guidance in the presence of transmission zero dynamics

    Science.gov (United States)

    Meyer, G.; Hunt, L. R.; Su, R.

    1995-01-01

    An iterative procedure is proposed for computing the commanded state trajectories and controls that guide a possibly multiaxis, time-varying, nonlinear system with transmission zero dynamics through a given arbitrary sequence of control points. The procedure is initialized by the system inverse with the transmission zero effects nulled out. Then the 'steady state' solution of the perturbation model with the transmission zero dynamics intact is computed and used to correct the initial zero-free solution. Both time domain and frequency domain methods are presented for computing the steady state solutions of the possibly nonminimum phase transmission zero dynamics. The procedure is illustrated by means of linear and nonlinear examples.

  11. 40 Gb/s optical transmission systems

    DEFF Research Database (Denmark)

    Buxens Azcoaga, Alvaro Juan; Nielsen, Steen Krogh

    2003-01-01

    application (maximum distance of 40 km) the maximum PMD coeficient allowed in the transmission fiber, 0.4 ps=pkm, is below the values defined by actual standards, 0.5 ps=pkm. The most promising PMD compensation methods are presented and their advantages and disadvantages are discussed. A PMD compensator based...

  12. Measurement of Transmission Error Including Backlash in Angle Transmission Mechanisms for Mechatronic Systems

    Science.gov (United States)

    Ming, Aiguo; Kajitani, Makoto; Kanamori, Chisato; Ishikawa, Jiro

    The characteristics of angle transmission mechanisms exert a great influence on the servo performance in the robotic or mechatronic mechanism. Especially, the backlash of angle transmission mechanism is preferable the small amount. Recently, some new types of gear reducers with non-backlash have been developed for robots. However, the measurement and evaluation method of the backlash of gear trains has not been considered except old methods which can statically measure at only several meshing points of gears. This paper proposes an overall performance testing method of angle transmission mechanisms for the mechatronic systems. This method can measure the angle transmission error both clockwise and counterclockwise. In addition the backlash can be continuously measured in all meshing positions automatically. This system has been applied to the testing process in the production line of gear reducers for robots, and it has been effective for reducing the backlash of the gear trains.

  13. Strategic Generation with Conjectured Transmission Price Responses in a Mixed Transmission Pricing System. Part 1. Formulation

    Energy Technology Data Exchange (ETDEWEB)

    Hobbs, B.F. [Department of Geography and Environmental Engineering, The Johns Hopkins University, Baltimore, MD (United States); Rijkers, F.A.M. [Office of Energy Regulation DTe, Den Haag (Netherlands)

    2004-05-01

    The conjectured supply function (CSF) model calculates an oligopolistic equilibrium among competing generating companies (GenCos), presuming that GenCos anticipate that rival firms will react to price increases by expanding their sales at an assumed rate. The CSF model is generalized here to include each generator's conjectures concerning how the price of transmission services (point-to-point service and constrained interfaces) will be affected by the amount of those services that the generator demands. This generalization reflects the market reality that large producers will anticipate that they can favorably affect transmission prices by their actions. The model simulates oligopolistic competition among generators while simultaneously representing a mixed transmission pricing system. This mixed system includes fixed transmission tariffs, congestion-based pricing of physical transmission constraints (represented as a linearized dc load flow), and auctions of interface capacity in a path-based pricing system. Pricing inefficiencies, such as export fees and no credit for counterflows, can be simulated. The model is formulated as a linear mixed complementarity problem, which enables very large market models to be solved. In the second paper of this two-paper series, the capabilities of the model are illustrated with an application to northwest Europe, where transmission pricing is based on such a mixture of approaches.

  14. Reform and Development of Educational Administration System in China

    Science.gov (United States)

    Li, Qiang; Wu, Zhongyuan

    2008-01-01

    The paper mainly introduces the development of the educational administration agency in China, including the evolution of the educational administration agency, the Course of instituting legal system of education in China, the missions of the now Minister of Education, questions emerged in the development of the educational administration system,…

  15. Distance Protection of Cross-Bonded Transmission Cable-Systems

    DEFF Research Database (Denmark)

    Bak, Claus Leth; F. Jensen, Christian

    2014-01-01

    In this paper the problems of protecting a cross-bonded cable system using distance protection are analysed. The combination of the desire to expand the high voltage transmission grid and the public's opinion towards new installations of overhead lines (OHL), more and more transmission cable syst...

  16. Underwater Acoustic Image Transmission System Based on DSP

    Institute of Scientific and Technical Information of China (English)

    Cheng En; Xu Ru

    2002-01-01

    The underwater acoustic image transmission system based on the high-speed DSP device TMS320C549 has been studied. We use Goertzel algorithm for source decoding and MFSK for modulation. Turbo code is used for channel coding and decoding. The purpose is to implement underwater video image data transmission.

  17. Long-lasting insecticidal nets are synergistic with mass drug administration for interruption of lymphatic filariasis transmission in Nigeria.

    Directory of Open Access Journals (Sweden)

    Abel Eigege

    Full Text Available In central Nigeria Anopheles mosquitoes transmit malaria and lymphatic filariasis (LF. The strategy used for interrupting LF transmission in this area is annual mass drug administration (MDA with albendazole and ivermectin, but after 8 years of MDA, entomological evaluations in sentinel villages showed continued low-grade mosquito infection rates of 0.32%. After long-lasting insecticidal net (LLIN distribution by the national malaria program in late 2010, however, we were no longer able to detect infected vectors over a 24-month period. This is evidence that LLINs are synergistic with MDA in interrupting LF transmission.

  18. INFORMATION-MEASURING TEST SYSTEM OF DIESEL LOCOMOTIVE HYDRAULIC TRANSMISSIONS

    Directory of Open Access Journals (Sweden)

    I. V. Zhukovytskyy

    2015-08-01

    Full Text Available Purpose. The article describes the process of developing the information-measuring test system of diesel locomotives hydraulic transmission, which gives the possibility to obtain baseline data to conduct further studies for the determination of the technical condition of diesel locomotives hydraulic transmission. The improvement of factory technology of post-repair tests of hydraulic transmissions by automating the existing hydraulic transmission test stands according to the specifications of the diesel locomotive repair enterprises was analyzed. It is achieved based on a detailed review of existing foreign information-measuring test systems for hydraulic transmission of diesel locomotives, BelAZ earthmover, aircraft tug, slag car, truck, BelAZ wheel dozer, some brands of tractors, etc. The problem for creation the information-measuring test systems for diesel locomotive hydraulic transmission is being solved, starting in the first place from the possibility of automation of the existing test stand of diesel locomotives hydraulic transmission at Dnipropetrovsk Diesel Locomotive Repair Plant "Promteplovoz". Methodology. In the work the researchers proposed the method to create a microprocessor automated system of diesel locomotives hydraulic transmission stand testing in the locomotive plant conditions. It acts by justifying the selection of the necessary sensors, as well as the application of the necessary hardware and software for information-measuring systems. Findings. Based on the conducted analysis there was grounded the necessity of improvement the plant hydraulic transmission stand testing by creating a microprocessor testing system, supported by the experience of developing such systems abroad. Further research should be aimed to improve the accuracy and frequency of data collection by adopting the more modern and reliable sensors in tandem with the use of filtering software for electromagnetic and other interference. Originality. The

  19. Vibration transmissibility characteristics of smart spring vibration isolation system

    Institute of Scientific and Technical Information of China (English)

    倪德; 朱如鹏; 陆凤霞; 鲍和云; 付秋菊

    2014-01-01

    The objective of this work was to study the vibration transmissibility characteristics of the undamped and damped smart spring systems. The frequency response characteristics of them were analyzed by using the equivalent linearization technique, and the possible types of the system motion were distinguished by using the starting and ending frequencies. The influences of system parameters on the vibration transmissibility characteristics were discussed. The following conclusions may be drawn from the analysis results. The undamped smart spring system may simultaneously have one starting frequency and one ending frequency or only have one starting frequency, and the damped system may simultaneously have two starting frequencies and one ending frequency. There is an optimal control parameter to make the peak value of the vibration transmissibility curve of the system be minimum. When the mass ratio is far away from the stiffness ratio, the vibration transmissibility is small. The effect of the damping ratio on the system vibration transmissibility is significant while the control parameter is less than its optimal value. But the influence of the relative damping ratio on the vibration transmissibility is small.

  20. Design of MAGLEV Information Transmission System by Radio Inductive Loop

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Sang Kweun [Taejon National University of Technology (Korea, Republic of); Park, Seok Ha; Kim, Jong Bum; Kim, Yang Mo [Chungnam National University (Korea, Republic of); Park, Jeong Soo [ACE Technology (Korea, Republic of)

    1999-01-01

    This paper presents the information transmission between on-board and ground-site in MAGLEV Considering safety and high speed operation and density operation and density operation information, transmission between them is necessary. Therefore it is necessary for transmission system to ensure high speed transmission, low error rate, massive information, and reliability of information. To provide above conditions, 1.1km signal line assembly was constructed and Frequency Shift Keying(FSK) modulation and Open System Interconnection(OSI) based high-level data link control(HDLC) protocol are applied, To modulate digital signal for transmission from ground-site to on-board, carrier frequency of 70khz is used and 90khz is used for transmission from on-board to ground-site. Transmission speed is 2400bps for consideration of train speed, quantity of information, and data error rate. And this paper introduces information monitoring considering user interface and presents the method for an effective data transmission in MAGLEV which is now being tested and intends to provide for an intelligent train operation in future. (author). 9 refs., 9 figs., 1 tab.

  1. Alternative electrical transmission systems and their environmental impact

    Energy Technology Data Exchange (ETDEWEB)

    Schiefelbein, G.F.

    1977-08-01

    A general description is provided of electrical transmission systems as an aid in determining their environmental impacts. Alternating current, direct current, overhead systems, underground systems, and water crossings are treated. The cost, performance, reliability, safety, and environmental impact of these systems are compared.

  2. Pediatric medication administration errors and workflow following implementation of a bar code medication administration system.

    Science.gov (United States)

    Hardmeier, Anna; Tsourounis, Candy; Moore, Mary; Abbott, Wendy E; Guglielmo, B Joseph

    2014-01-01

    Direct observation was used to detect medication errors and Bar Code Medication Administration (BCMA) workarounds on two pediatric units and one neonatal unit at UCSF Benioff Children's Hospital. The study (1) measured the frequency of nursing medication administration-related errors, (2) characterized the types of medication errors, (3) assessed compliance with the institution's six medication administration safety processes, and (4) identified observed workarounds following BCMA implementation. The results of the direct observation were compared to medication administration-related incident reports (IRs) for the same period. The frequency of medication errors was 5% for the three units. Compliance with the process measures was achieved 86% of the time (range 23-100%). Seven medication administration-related IRs were submitted during the same observation period. Three BCMA workarounds were identified; (1) failure to visually confirm patient's identification, (2) failure to compare the medication to the electronic medication administration record at least twice before administration, and (3) charting administration of medication before actual administration. The direct observation methodology identified a low frequency of medication administration errors (MAEs) consistent with post-BCMA implementation. The incident reporting system identified different MAEs than direct observation suggesting that both methods should be used to better characterize the scope of MAEs.

  3. Transmission Reinforcements in the Central American Regional Power System

    Energy Technology Data Exchange (ETDEWEB)

    Elizondo, Marcelo A.; Vallem, Mallikarjuna R.; Samaan, Nader A.; Makarov, Yuri V.; Vyakaranam, Bharat; Nguyen, Tony B.; Munoz, Christian; Herrera, Ricardo; Midence, Diego; Shpitsberg, Anna

    2016-07-25

    The Central American regional interconnected power system (SER) connects the countries members of the Central American regional electricity market (MER): Guatemala, El Salvador, Honduras, Nicaragua, Costa Rica, and Panama. The SER was a result of a long term regional effort, and was initially conceived to transfer 300 MW between countries. However, the current transfer limits between countries range from 70 MW to 300 MW. Regional entities, like CRIE (Regional Commission of Electrical Interconnection), EOR (Central American Regional System Operator), and CDMER (Board of Directors of the Central American Market) are working on coordinating the national transmission expansion plans with regional transmission planning efforts. This paper presents experience in Central America region to recommend transmission reinforcements to achieve 300 MW transfer capacity between any pair of member countries of the Central American regional electricity market (MER). This paper also provides a methodology for technical analysis and for coordination among the regional and national entities. This methodology is unique for transmission systems of these characteristics.

  4. Cost estimation of HVDC transmission system of Bangka's NPP candidates

    Science.gov (United States)

    Liun, Edwaren; Suparman

    2014-09-01

    Regarding nuclear power plant development in Bangka Island, it can be estimated that produced power will be oversupply for the Bangka Island and needs to transmit to Sumatra or Java Island. The distance between the regions or islands causing considerable loss of power in transmission by alternating current, and a wide range of technical and economical issues. The objective of this paper addresses to economics analysis of direct current transmission system to overcome those technical problem. Direct current transmission has a stable characteristic, so that the power delivery from Bangka to Sumatra or Java in a large scale efficiently and reliably can be done. HVDC system costs depend on the power capacity applied to the system and length of the transmission line in addition to other variables that may be different.

  5. A linear signal transmission system calibration method of wideband GPR

    Science.gov (United States)

    Wu, Bin; Zhao, Kai; Gu, Ling-jia; Cao, Qiong; Li, Xiao-feng; Zheng, Xing-ming

    2016-09-01

    In VHF pulse Ground Penetrating Radar(GPR) system, the echo pass through the antenna and transmission line circuit, then reach the GPR receiver. Thus the reflection coefficient at the receiver sampling gate interface, which is at the end of the transmission line, is different from the real reflection coefficient of the media at the antenna interface, which could cause the GPR receiving error. The pulse GPR receiver is a wideband system that can't be simply described as traditional narrowband transmission line model. Since the GPR transmission circuit is a linear system, the linear transformation method could be used to analyze the characteristic of the GPR receiving system. A GPR receiver calibration method based on transmission line theory is proposed in this paper, which analyzes the relationship between the reflection coefficients of theory calculation at antenna interface and the measuring data by network analyzer at the sampling gate interface. Then the least square method is introduced to calibrate the transfer function of the GPR receiver transmission circuit. This calibration method can be useful in media quantitative inversion by GPR. When the reflection coefficient at the sampling gate is obtained, the real reflection coefficient of the media at the antenna interface can be easily determined.

  6. Optimal Transmission Power in a Nonlinear VLC System

    Institute of Scientific and Technical Information of China (English)

    ZHAO Shuang; CAI Sunzeng; KANG Kai; QIAN Hua

    2016-01-01

    In a visible light communication (VLC) system, the light emitting diode (LED) is nonlinear for large signals, which limits the trans⁃mission power or equivalently the coverage of the VLC system. When the input signal amplitude is large, the nonlinear distortion creates harmonic and intermodulation distortion, which degrades the transmission error vector magnitude (EVM). To evaluate the impact of nonlinearity on system performance, the signal to noise and distortion ratio (SNDR) is applied, defined as the linear sig⁃nal power over the thermal noise plus the front end nonlinear distortion. At a given noise level, the optimal system performance can be achieved by maximizing the SNDR, which results in high transmission rate or long transmission range for the VLC system. In this paper, we provide theoretical analysis on the optimization of SNDR with a nonlinear Hammerstein model of LED. Simula⁃tion results and lab experiments validate the theoretical analysis.

  7. Administration

    DEFF Research Database (Denmark)

    Bogen handler om den praksis, vi kalder administration. Vi er i den offentlige sektor i Danmark hos kontorfolkene med deres sagsmapper, computere, telefoner,, lovsamlinger,, retningslinier og regneark. I bogen udfoldes en mangfoldighed af konkrete historier om det administrative arbejde fra...... forskellige områder i den offentlige sektor. Hensigten er at forstå den praksis og faglighed der knytter sig til det administrative arbejde...

  8. Rhode Island Model Evaluation & Support System: Building Administrator. Edition III

    Science.gov (United States)

    Rhode Island Department of Education, 2015

    2015-01-01

    Rhode Island educators believe that implementing a fair, accurate, and meaningful educator evaluation and support system will help improve teaching, learning, and school leadership. The primary purpose of the Rhode Island Model Building Administrator Evaluation and Support System (Rhode Island Model) is to help all building administrators improve.…

  9. Tidal current turbine based on hydraulic transmission system

    Institute of Scientific and Technical Information of China (English)

    Hong-wei LIU; Wei LI; Yong-gang LIN; Shun MA

    2011-01-01

    Tidal current turbines (TCTs) are newly developed electricity generating devices.Aiming at the stabilization of the power output of TCTs,this paper introduces the hydraulic transmission technologies into TCTs.The hydrodynamics of the turbine was analyzed at first and its power output characteristics were predicted.A hydraulic power transmission system and a hydraulic pitch-controlled system were designed.Then related simulations were conducted.Finally,a TCT prototype was manufactured and tested in the workshop.The test results have confirmed the correctness of the current design and availability of installation of the hydraulic system in TCTs.

  10. FPGA Implementation of Video Transmission System Based on LTE

    Directory of Open Access Journals (Sweden)

    Lu Yan

    2015-01-01

    Full Text Available In order to support high-definition video transmission, an implementation of video transmission system based on Long Term Evolution is designed. This system is developed on Xilinx Virtex-6 FPGA ML605 Evaluation Board. The paper elaborates the features of baseband link designed in Xilinx ISE and protocol stack designed in Xilinx SDK, and introduces the process of setting up hardware and software platform in Xilinx XPS. According to test, this system consumes less hardware resource and is able to transmit bidirectional video clearly and stably.

  11. Subcarrier multiplexing tolerant dispersion transmission system employing optical broadband sources.

    Science.gov (United States)

    Grassi, Fulvio; Mora, José; Ortega, Beatriz; Capmany, José

    2009-03-16

    This paper presents a novel SCM optical transmission system for next-generation WDM-PONs combining broadband optical sources and a Mach-Zehnder interferometric structure. The approach leeds to transport RF signals up to 50 GHz being compatible with RoF systems since a second configuration has been proposed in order to overcome dispersion carrier suppression effect using DSB modulation. The theoretical analysis validates the potentiality of the system also considering the effects of the dispersion slope over the transmission window.

  12. VLBI data transmission system using multiple IP streams

    Science.gov (United States)

    Uose, Hisao

    We have developed an IP-based data transmission system which can directly replace K4 (ID1) VLBI data recorder. It employs multiple TCP data steams and individual buffers to cope with variable usable bandwidth we encouter when we use shared academic networks. This paper describes the outline of the system and preliminary testing results.

  13. Load flow computations in hybrid transmission - distributed power systems

    NARCIS (Netherlands)

    Wobbes, E.D.; Lahaye, D.J.P.

    2013-01-01

    We interconnect transmission and distribution power systems and perform load flow computations in the hybrid network. In the largest example we managed to build, fifty copies of a distribution network consisting of fifteen nodes is connected to the UCTE study model, resulting in a system consisting

  14. Information Network Systems and Information Sharing on Administrative Websites

    Institute of Scientific and Technical Information of China (English)

    HIROTA Denjiro

    2004-01-01

    In Japanese "e-government" policy, called "e-Japan", the "administrative document management system" is functioning as information searching systems. On the other hand, this system has also generated the problem that it is not fully functioning as a means for the information sharing in a governmental agency. So, the purpose of this research is to find how the administrative document management system can function as information sharing in administrative organization. For this purpose,this paper considers the current status and some problems firstly. And secondary, this paper proposes the idea and constructs some information systems using administrative official Website. This is the method and approach of this research. As a conclusion, this proposal information system functions as information sharing support systems.

  15. NASA Administrative Data Base Management Systems, 1984

    Science.gov (United States)

    Radosevich, J. D. (Editor)

    1984-01-01

    Strategies for converting to a data base management system (DBMS) and the implementation of the software packages necessary are discussed. Experiences with DBMS at various NASA centers are related including Langley's ADABAS/NATURAL and the NEMS subsystem of the NASA metrology informaton system. The value of the integrated workstation with a personal computer is explored.

  16. Cryogenic System for a High Temperature Superconducting Power Transmission Cable

    Energy Technology Data Exchange (ETDEWEB)

    Demko, J.A.; Gouge, M.J.; Hughey, R.L.; Lue, J.W.; Martin, R.; Sinha, U.; Stovall, J.P.

    1999-07-12

    High-temperature superconducting (HTS) cable systems for power transmission are under development that will use pressurized liquid nitrogen to provide cooling of the cable and termination hardware. Southwire Company and Oak Ridge National Laboratory have been operating a prototype HTS cable system that contains many of the typical components needed for a commercial power transmission application. It is being used to conduct research in the development of components and systems for eventual commercial deployment. The cryogenic system was built by Air Products and Chemicals, Allentown, Pennsylvania, and can circulate up to 0.35 kg/s of liquid nitrogen at temperatures as low as 67 K at pressures of 1 to 10 bars. Sufficient cooling is provided for testing a 5-m-long HTS transmission cable system that includes the terminations required for room temperature electrical connections. Testing of the 5-m HTS transmission cable has been conducted at the design ac conditions of 1250 A and 7.5 kV line to ground. This paper contains a description of the essential features of the HTS cable cryogenic system and performance results obtained during operation of the system. The salient features of the operation that are important in large commercial HTS cable applications will be discussed.

  17. Stokes Space in Direct-Detection Data Transmission Systems

    DEFF Research Database (Denmark)

    Estaran Tolosa, Jose Manuel; Lu, Xiaofeng; Zibar, Darko;

    2015-01-01

    Stokes-based processing permits complete and phase-insensitive characterization of the field’s SOP, readily unlocking polarization diversity in transmission systems where DD is desired. We present an overview on Stokes notions and most recent achievements in this context.......Stokes-based processing permits complete and phase-insensitive characterization of the field’s SOP, readily unlocking polarization diversity in transmission systems where DD is desired. We present an overview on Stokes notions and most recent achievements in this context....

  18. Technology for extending transmission distance of EPON system

    Institute of Scientific and Technical Information of China (English)

    Li ZHANG; Deming LIU; Cbuanbao ZHANG; Guangsbeng WU

    2009-01-01

    At present, the maximal transmission distance between the optical line terminal (OLT) and opticalnetwork unit (ONU) of an Ethemet passive optical network (EPON) system is 20 km.However, this distance should be extended to 50 km or even longer in some applications such as fiber to the village (FTTV).A method for extending the transmission distance of an EPON system is proposed in this paper, in which the optical power amplifier and the adjustment of dynamic bandwidth allocation (DBA) are the key technologies.

  19. A Proposal on Low Frequency AC Transmission as a Multi-Terminal Transmission System

    Directory of Open Access Journals (Sweden)

    Achara Pichetjamroen

    2016-08-01

    Full Text Available This paper is focused on the discussion and comparison of characteristics and behavior of three low frequency ac (LFAC transmission system configurations operating under the same control scheme and conditions to identify the most promising operation system for LFAC. Merits of LFAC over high voltage direct current (HVDC are mentioned first. By changing power flow direction without auxiliary switches in multi-terminal application and easiness of short circuit protection are explained. The three configurations of LFACs are described and applied by the control scheme with the aid of the tool of the PSCAD/EMTDC software to consider the behavior of each LFAC system on line frequency and low frequency sides. For two-phase system, no fluctuation occurs on the line frequency side, which is the advantage over single-phase system. Furthermore, current rating on thyristor devices during operation and number of devices that used in each type of LFAC are calculated and compared. These results can lead to determine the most suitable transmission system for the LFAC system operation.

  20. HIV transmission in a state prison system, 1988-2005.

    Directory of Open Access Journals (Sweden)

    Krishna Jafa

    Full Text Available INTRODUCTION: HIV prevalence among state prison inmates in the United States is more than five times higher than among nonincarcerated persons, but HIV transmission within U.S. prisons is sparsely documented. We investigated 88 HIV seroconversions reported from 1988-2005 among male Georgia prison inmates. METHODS: We analyzed medical and administrative data to describe seroconverters' HIV testing histories and performed a case-crossover analysis of their risks before and after HIV diagnosis. We sequenced the gag, env, and pol genes of seroconverters' HIV strains to identify genetically-related HIV transmission clusters and antiretroviral resistance. We combined risk, genetic, and administrative data to describe prison HIV transmission networks. RESULTS: Forty-one (47% seroconverters were diagnosed with HIV from July 2003-June 2005 when voluntary annual testing was offered. Seroconverters were less likely to report sex (OR [odds ratio] = 0.02, 95% CI [confidence interval]: 0-0.10 and tattooing (OR = 0.03, 95% CI: <0.01-0.20 in prison after their HIV diagnosis than before. Of 67 seroconverters' specimens tested, 33 (49% fell into one of 10 genetically-related clusters; of these, 25 (76% reported sex in prison before their HIV diagnosis. The HIV strains of 8 (61% of 13 antiretroviral-naïve and 21 (40% of 52 antiretroviral-treated seroconverters were antiretroviral-resistant. DISCUSSION: Half of all HIV seroconversions were identified when routine voluntary testing was offered, and seroconverters reduced their risks following their diagnosis. Most genetically-related seroconverters reported sex in prison, suggesting HIV transmission through sexual networks. Resistance testing before initiating antiretroviral therapy is important for newly-diagnosed inmates.

  1. A New Design of Video Streaming Capture and Transmission System

    Directory of Open Access Journals (Sweden)

    Xingyu Geng

    2014-10-01

    Full Text Available Aiming to solve some existing problems such as low video streaming rate, high cost and complex set-up, a new video streaming capture and transmission system based on servfox is proposed. This system uses servfox to invoke V4L APIs to capture video streaming in Linux operating system, and then transmits the data to a remote monitoring client through Internet which can display the video streaming. Remote client can be either a software or a web browser. The experimental results show that the image captured by this system is high-quality and the streaming rate is high. At the same time, the system possesses high reliability and low cost. Compared with existing methods, this system can be widely used in the process of video streaming capture and transmission

  2. Power Transmission System Vulnerability Assessment Using Genetic Algorithm

    Directory of Open Access Journals (Sweden)

    E. Karimi

    2012-11-01

    Full Text Available Recent blackouts in power systems have shown the necessity of vulnerability assessment. Among all factors, transmission system components have a more important role. Power system vulnerability assessment could capture cascading outages which result in large blackouts and is an effective tool for power system engineers for defining power system bottlenecks and weak points. In this paper a new method based on fault chains concept is developed which uses new measures. Genetic algorithm with an effective structure is used for finding vulnerable branches in a practical power transmission system. Analytic hierarchy process is a technique used to determine the weighting factors in fitness function of genetic algorithm. Finally, the numerical results for Isfahan Regional Electric Company are presented which verifies the effectiveness and precision of the proposed method according to the practical expriments.

  3. Impedance matching wireless power transmission system for biomedical devices.

    Science.gov (United States)

    Lum, Kin Yun; Lindén, Maria; Tan, Tian Swee

    2015-01-01

    For medical application, the efficiency and transmission distance of the wireless power transfer (WPT) are always the main concern. Research has been showing that the impedance matching is one of the critical factors for dealing with the problem. However, there is not much work performed taking both the source and load sides into consideration. Both sides matching is crucial in achieving an optimum overall performance, and the present work proposes a circuit model analysis for design and implementation. The proposed technique was validated against experiment and software simulation. Result was showing an improvement in transmission distance up to 6 times, and efficiency at this transmission distance had been improved up to 7 times as compared to the impedance mismatch system. The system had demonstrated a near-constant transfer efficiency for an operating range of 2cm-12cm.

  4. Medical data transmission system for remote healthcare centres

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, E A; Cagnolo, F J; Olmos, C E; Centeno, C A; Riva, G G; Zerbini, C A [Clinical Engineering Group, National Technological University, Cordoba Regional Faculty, Maestro M Lopez St and Cruz Roja Argentina St, Cordoba (Argentina)

    2007-11-15

    The main motivation of this project is to improve the healthcare centres equipment and human resources efficiency, enabling those centres for transmission of parameters of medical interest. This system facilitates remote consultation, in particular between specialists and remote healthcare centres. Likewise it contributes to the qualification of professionals. The electrocardiographic (ECG) and electroencephalographic (EEG) signals are acquired, processed and then sent, fulfilling the effective norms, for application in the hospital network of Cordoba Province, which has nodes interconnected by phone line. As innovative aspects we emphasized the low cost of development and maintenance, great versatility and handling simplicity with a modular design for interconnection with diverse data transmission media (Wi-Fi, GPRS, etc.). Successfully experiences were obtained during the acquisition of the signals and transmissions on wired LAN networks. As improvements, we can mention: energy consumption optimization and mobile communication systems usage, in order to offer more autonomy.

  5. Expert Systems for Civilian Personnel Administration,

    Science.gov (United States)

    1985-07-01

    April 1985. Doherty, Michael J. "Comments on Sixth Generation Computers." Dr. Dobb’s Journal, #92 June, 1984. Doyle, Jon . "Expert Systems Without...853-5593. Lisp Machine, Inc. Los Angeles, CA. Mr. Kenneth Gruber . (213) 642-1116. Santa Clara, CA. Mr. Warren Goddard. (408) 496-1151. Scientific

  6. Guidelines for transient analysis in water transmission and distribution systems

    OpenAIRE

    Pothof, Ivo; Karney, Bryan

    2012-01-01

    All water systems leak, and many supply systems do so considerably, with water losses typically of approximately 20% of the water production. The IWA Water Loss Task Force aims for a significant reduction of annual water losses by drafting documents to assist practitioners and others to prevent, monitor and mitigate water losses in water transmission and distribution systems. One of the causes of water losses are transient phenomena, caused by normal and accidental pump and valve operations. ...

  7. Advanced coding techniques for few mode transmission systems.

    Science.gov (United States)

    Okonkwo, Chigo; van Uden, Roy; Chen, Haoshuo; de Waardt, Huug; Koonen, Ton

    2015-01-26

    We experimentally verify the advantage of employing advanced coding schemes such as space-time coding and 4 dimensional modulation formats to enhance the transmission performance of a 3-mode transmission system. The performance gain of space-time block codes for extending the optical signal-to-noise ratio tolerance in multiple-input multiple-output optical coherent spatial division multiplexing transmission systems with respect to single-mode transmission performance are evaluated. By exploiting the spatial diversity that few-mode-fibers offer, with respect to single mode fiber back-to-back performance, significant OSNR gains of 3.2, 4.1, 4.9, and 6.8 dB at the hard-decision forward error correcting limit are demonstrated for DP-QPSK 8, 16 and 32 QAM, respectively. Furthermore, by employing 4D constellations, 6 × 28Gbaud 128 set partitioned quadrature amplitude modulation is shown to outperform conventional 8 QAM transmission performance, whilst carrying an additional 0.5 bit/symbol.

  8. System Administration Support/SWORDS G2

    Science.gov (United States)

    Dito, Scott Joseph

    2014-01-01

    The Soldier-Warfighter Operationally Responsive Deployer for Space (SWORDS) rocket is a dedicated small satellite launcher that will minimize danger and complexity in order to allow soldiers in the field to put payloads of up to 25kg into orbit from the field. The SWORDSG2 project is the development of a model, simulation, and ultimately a working application that will control and monitor the cryogenic fluid delivery to the SWORDS rocket for testing purposes. To accomplish this, the project is using the programming language environment Gensym G2. The environment is an all-inclusive application that allows development, testing, modeling, and finally operation of the unique application through graphical and programmatic methods. In addition, observation of the current cryogenic fluid delivery system in the Kennedy Space Center Cry Lab has allowed me to gain valuable experience of fluid systems and propelant delivery that is valuable to our team when developing amd modeling our own system.The ultimate goal of having a test-ready application to show to the heads of the project, and demonstrating G2's capabilities, by late 2014 will require hard work and intense study and understanding of not only the programming aspect but also the physical phenomena we want to model, observe, and control.

  9. Federal Emergency Management Information System (FEMIS) System Administration Guide for FEMIS Version 1.5

    Energy Technology Data Exchange (ETDEWEB)

    Bower, John C.(BATTELLE (PACIFIC NW LAB)); Burnett, Robert A.(BATTELLE (PACIFIC NW LAB)); Carter, Richard J.(BATTELLE (PACIFIC NW LAB)); Downing, Timothy R.(BATTELLE (PACIFIC NW LAB)); Homer, Brian J.(BATTELLE (PACIFIC NW LAB)); Holter, Nancy A.(BATTELLE (PACIFIC NW LAB)); Johnson, Daniel M.(BATTELLE (PACIFIC NW LAB)); Johnson, Ranata L.(BATTELLE (PACIFIC NW LAB)); Johnson, Sharon M.(BATTELLE (PACIFIC NW LAB)); Loveall, Robert M.(BATTELLE (PACIFIC NW LAB)); Ramos Jr., Juan (BATTELLE (PACIFIC NW LAB)); Schulze, Stacy A.(BATTELLE (PACIFIC NW LAB)); Sivaraman, Chitra (BATTELLE (PACIFIC NW LAB)); Stephan, Alex J.(BATTELLE (PACIFIC NW LAB)); Stoops, Lamar R.(BATTELLE (PACIFIC NW LAB)); Wood, Blanche M.(BATTELLE (PACIFIC NW LAB))

    2001-12-01

    The Federal Emergency Management System (FEMIS) is an emergency management planning and response tool. The FEMIS System Administration Guide provides information on FEMIS System Administrator activities as well as the utilities that are included with FEMIS.

  10. Ivermectin Mass Drug Administration to Humans Disrupts Malaria Parasite Transmission in Senegalese Villages

    OpenAIRE

    Kobylinski, Kevin C; Sylla, Massamba; Chapman, Phillip L.; Sarr, Moussa D.; Foy, Brian D

    2011-01-01

    Ivermectin mass drug administration (MDA) to humans is used to control onchocerciasis and lymphatic filariasis. Recent field studies have shown an added killing effect of ivermectin MDA against malaria vectors. We report that ivermectin MDA reduced the proportion of Plasmodium falciparum infectious Anopheles gambiae sensu stricto (s.s.) in treated villages in southeastern Senegal. Ivermectin MDA is a different delivery method and has a different mode of action from current malaria control age...

  11. A CONTACTLESS TRANSMITTER FOR THE M TYPE DATA TRANSMISSION SYSTEM.

    Science.gov (United States)

    A contactless transmitter employing electromagnetic principles for the M type data transmission system is described. It could be contained in a size 11 standard housing if the six semiconductor main switches are mounted externally. Tests showed that the transmitter will operate satisfactorily at speeds in excess of 3000 rev/min, and that it could form the basis of a brushless dc motor . (Author)

  12. Using Word Processing to Implement an Effective Administrative Support System

    Science.gov (United States)

    Taylor, Wendy

    1978-01-01

    Describes the steps taken to reorganize the Administrative Support System of Houston Independent School District, to make it more efficient. A more flexible multi-function support team replaced the traditional private secretaries arrangement. (GA)

  13. A development of ITV system for power transmission line monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Hong Keun; Kim, Seok Ku; Lee, Kwang Joong; Lee, Won Bin [Korea Electric Power Corp. (KEPCO), Taejon (Korea, Republic of). Research Center

    1995-12-31

    Transmission lines which are important to supply the electricity installed on the terrestrially severe site such as mountains needed to be monitored to prevent electric fault by snow accelerating, icing, tree contact, fire etc. Inspections by human patrol has been done but it seems not so efficient and satisfiable. To cope with this a transmission line monitoring system using industrial television and OPGW was developed and field trilled at the site. This paper describes about the optical video transceiver, video distributor and control devices (author).

  14. Administrative law risks of the governmental and municipal procurement system

    Directory of Open Access Journals (Sweden)

    Dyuzhikov Sergey, A.

    2015-09-01

    Full Text Available The paper deals with the administrative law risks of the Russian system of public procurement. The authors analyze the foregoing risks in the view of the correlation of risk situations, risk actions (omission and administrative law prohibitions. The authors are considering problems of the subject and some other characteristics essential to the administrative offenses in terms of the most systemic risk in this sphere – an information risk. The materials on law practice open to general use generated in more than 25 entities of the Russian Federation were used in the paper while preparing.

  15. Selective transmission and channel estimation in massive MIMO systems

    Institute of Scientific and Technical Information of China (English)

    杨睿哲

    2016-01-01

    Massive MIMO systems have got extraordinary spectral efficiency using a large number of base station antennas, but it is in the challenge of pilot contamination using the aligned pilots.To address this issue, a selective transmission is proposed using time-shifted pilots with cell grouping, where the strong interfering users in downlink transmission cells are temporally stopped during the pilots transmission in uplink cells.Based on the spatial characteristics of physical channel models, the strong interfering users are selected to minimize the inter-cell interference and the cell grouping is designed to have less temporally stopped users within a smaller area.Furthermore, a Kalman estima-tor is proposed to reduce the unexpected effect of residual interferences in channel estimation, which exploits both the spatial-time correlation of channels and the share of the interference information. The numerical results show that our scheme significantly improves the channel estimation accuracy and the data rates.

  16. Model documentation: Natural gas transmission and distribution model of the National Energy Modeling System. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-02-17

    The Natural Gas Transmission and Distribution Model (NGTDM) is the component of the National Energy Modeling System (NEMS) that is used to represent the domestic natural gas transmission and distribution system. NEMS was developed in the Office of integrated Analysis and Forecasting of the Energy information Administration (EIA). NEMS is the third in a series of computer-based, midterm energy modeling systems used since 1974 by the EIA and its predecessor, the Federal Energy Administration, to analyze domestic energy-economy markets and develop projections. The NGTDM is the model within the NEMS that represents the transmission, distribution, and pricing of natural gas. The model also includes representations of the end-use demand for natural gas, the production of domestic natural gas, and the availability of natural gas traded on the international market based on information received from other NEMS models. The NGTDM determines the flow of natural gas in an aggregate, domestic pipeline network, connecting domestic and foreign supply regions with 12 demand regions. The methodology employed allows the analysis of impacts of regional capacity constraints in the interstate natural gas pipeline network and the identification of pipeline capacity expansion requirements. There is an explicit representation of core and noncore markets for natural gas transmission and distribution services, and the key components of pipeline tariffs are represented in a pricing algorithm. Natural gas pricing and flow patterns are derived by obtaining a market equilibrium across the three main elements of the natural gas market: the supply element, the demand element, and the transmission and distribution network that links them. The NGTDM consists of four modules: the Annual Flow Module, the Capacity F-expansion Module, the Pipeline Tariff Module, and the Distributor Tariff Module. A model abstract is provided in Appendix A.

  17. Fast isolation of faults in transmission systems using current transients

    Energy Technology Data Exchange (ETDEWEB)

    Perera, N.; Rajapakse, A.D. [University of Manitoba, Department of Electrical and Computer Engineering, Engineering Building, 15 Gillson Street, Winnipeg, Manitoba (Canada)

    2008-09-15

    This paper presents a protection scheme that is capable of very fast isolation of faults in high voltage transmission systems. Proposed scheme comprises set of relays connected through a telecommunication network, located at different nodes of the system. Relays use wavelet coefficients of current signals to identify the fault directions relative to their location. Fault directions identified at different locations in the system can be combined to determine the faulted line (or busbar) and isolate it. A robust single ended traveling wave based fault distance estimation approach is proposed as a backup in case of communication failure. Investigations were carried out using time domain simulations in PSCAD/EMTDC for a high voltage transmission system. (author)

  18. DistFlow Extensions for AC Transmission Systems

    OpenAIRE

    Coffrin, Carleton; Hijazi, Hassan L.; Van Hentenryck, Pascal

    2015-01-01

    Convex relaxations of the power flow equations and, in particular, the Semi-Definite Programming (SDP), Second-Order Cone (SOC), and Convex DistFlow (CDF) relaxations, have attracted significant interest in recent years. Thus far, studies of the CDF model and its connection to the other relaxations have been limited to power distribution systems, which omit several parameters necessary for modeling transmission systems. To increase the applicability of the CDF relaxation, this paper develops ...

  19. The Application of Standardization System in Corporate Management and Administration

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    This paper briefly discusses three important components of corporate standardization system and their functions and how such a system can be used in corporate management and administration. It also offers certain solutions and suggestions to some of the existing problems in the process of implementing corporate standardization system.

  20. Natural gas transmission and distribution model of the National Energy Modeling System

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-02-01

    The Natural Gas Transmission and Distribution Model (NGTDM) is the component of the National Energy Modeling System (NEMS) that is used to represent the domestic natural gas transmission and distribution system. NEMS was developed in the Office of Integrated Analysis and Forecasting of the Energy Information Administration (EIA). NEMS is the third in a series of computer-based, midterm energy modeling systems used since 1974 by the EIA and its predecessor, the Federal Energy Administration, to analyze domestic energy-economy markets and develop projections. From 1982 through 1993, the Intermediate Future Forecasting System (IFFS) was used by the EIA for its analyses, and the Gas Analysis Modeling System (GAMS) was used within IFFS to represent natural gas markets. Prior to 1982, the Midterm Energy Forecasting System (MEFS), also referred to as the Project Independence Evaluation System (PIES), was employed. NEMS was developed to enhance and update EIA`s modeling capability by internally incorporating models of energy markets that had previously been analyzed off-line. In addition, greater structural detail in NEMS permits the analysis of a broader range of energy issues. The time horizon of NEMS is the midterm period (i.e., through 2015). In order to represent the regional differences in energy markets, the component models of NEMS function at regional levels appropriate for the markets represented, with subsequent aggregation/disaggregation to the Census Division level for reporting purposes.

  1. Aswan HighDam/Cairo proposed HVDC transmission system

    Directory of Open Access Journals (Sweden)

    Ahmed Y.M.R. Salama

    2014-03-01

    The DC lines can carry more much power with two conductors than the power transmitted using an AC lines with three conductors of the same size. For the given power level, a DC line requires simpler and cheaper towers (From economical point of view, already installed towers for AC system can be used. Also reduced conductor sizes and insulator can be used. The power transmission losses also will be reduced to about two-thirds of the comparable AC system. The absence of skin effect with DC is also beneficial in reducing power losses marginally. Due to its fast controllability, HVDC transmission system has full control over transmitted power, an ability to enhance transient and dynamic stability in associated AC networks and can limit fault currents levels in the DC lines.

  2. Productive efficiency in electricity transmission and distribution systems

    Energy Technology Data Exchange (ETDEWEB)

    Pollitt, M.G. [Oxford Univ. (United Kingdom)

    1994-09-01

    This paper presents a Data Envelopment Analysis (DEA) and an OLS analysis of productive efficiency (cost efficiency) in 129 electricity transmission and 145 electricity distribution systems operating in the accounting year 1990. The transmission data contains US electric systems while the distribution data includes 136 US and 9 UK companies. The paper tests the null hypothesis that privately owned and publicly owned electricity systems do not have significantly different costs. The results of the analysis indicate two things: firstly, a strong inability to reject the null hypothesis in favour of the alternative hypothesis that privately owned firms are more efficient; and secondly, a relatively high level of technical efficiency within the UK companies in the year immediately prior to privatisation. (author)

  3. Transmission dispatch and congestion management in open market systems

    Science.gov (United States)

    Fang, Risheng

    This thesis is located in the domain of electricity supply industry restructuring. It deals with emerging issues, whose understanding is essential to advancing knowledge of open access transmission theory and proceeds to develop approaches for solving the transmission dispatch and congestion management problem. An overview of current trends and experiences in utility restructuring and the main models for restructuring, as well as the classifications of system operators, is first presented. A fully unbundled competitive electricity market model, called the bilateral/multilateral trades model, is then developed. A survey of current research in transmission dispatch and congestion management is included with discussion of transmission capacity and ancillary services. A methodology for the power dispatch problem in a structure dominated by bilateral and multilateral transmission contracts is presented. Group structures are mathematically formulated and explored and three basic types of curtailment strategies proposed for use by market participants. A more complex model is then developed, which takes into account the co-existence of bilateral and multilateral contracts with pool type dynamic supplies and demands based on bids and market clearing prices. An integrated dispatch strategy to reconcile all three types of transactions (bilateral, multilateral and pool) is then developed. Prioritization of electricity transactions and related curtailment strategies are explored and a mechanism for coordination between market participants to achieve additional economic advantages is described. A theory of security based rescheduling is presented in order to investigate the security-related aspects of operation in an unbundled and deregulated system. The impact of post-contingency corrective capability on optimal rescheduling results has been identified and the advantage of incorporating post-contingency corrective rescheduling into the objective function demonstrated. Finally

  4. The transmission link of CAPS navigation and communication system

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    The Chinese Area Positioning System (CAPS) is based on communication satellites with integrated capability, which is different from the Global Positioning System (GPS), the International Maritime Satellite Organization (Inmarsat) and so on. CAPS works at C-band, and its navigation information is not directly generated from the satellite, but from the master control station on the ground and transmitted to users via the satellite. The slightly inclined geostationary-satellite orbit (SIGSO) satellites are adopted in CAPS. All of these increase the difficulty in the design of the system and terminals. In this paper, the authors study the CAPS configuration parameters of the navigation master control station, information transmission capability, and the selection of the antenna aperture of the communication center station, as well as the impact of satellite parameters on the whole communication system from the perspective of the transmission link budget. The conclusion of availability of the CAPS navigation system is achieved. The results show that the CAPS inbound communication system forms a new low-data-rate satellite communication system, which can accommodate mass communication terminals with the transmission rate of no more than 1 kbps for every terminal. The communication center station should be configured with a large-aperture antenna (about 10-15 m); spread spectrum com- munication technology should be used with the spreading gain as high as about 40 dB; reduction of the satellite transponder gain attenuation is beneficial to improving the signal-to-noise ratio of the system, with the attenuation value of 0 or 2 dB as the best choice. The fact that the CAPS navigation system has been checked and accepted by the experts and the operation is stable till now clarifies the rationality of the analysis results. The fact that a variety of experiments and applications of the satellite communication system designed according to the findings in this paper have been

  5. Data Acquisition and Transmission System for Building Energy Consumption Monitoring

    Directory of Open Access Journals (Sweden)

    Liang Zhao

    2013-01-01

    Full Text Available Building energy consumption monitoring and management system have been developed widely in China in order to gain the real-time data of energy consumption in buildings for analyzing it in the next state work. This paper describes a low-cost and small-sized collector based on the STM32 microcontroller, which can be placed in a building easily to implement the work of data acquisition, storage, and transmission. The collector gathers the electricity, water, heat, and energy consumption data through the RS485 field bus and stores the data into an SD card with mass storage, finally, using Internet to finish the communication and transmission to data server through TCP protocol. The collector has been used in application for two years, and the results show that the system is reliable and stable.

  6. Energy-Efficient Transmission Schemes in Cooperative Cellular Systems

    CERN Document Server

    Yang, Wei; Wang, Ying; Sun, Wanlu

    2010-01-01

    Energy-efficient communication is an important requirement for mobile devices, as the battery technology has not kept up with the growing requirements stemming from ubiquitous multimedia applications. This paper considers energy-efficient transmission schemes in cooperative cellular systems with unbalanced traffic between uplink and downlink. Theoretically, we derive the optimal transmission data rate, which minimizes the total energy consumption of battery-powered terminals per information bit. The energy-efficient cooperation regions are then investigated to illustrate the effects of relay locations on the energy-efficiency of the systems, and the optimal relay location is found for maximum energy-efficiency. Finally, numerical results are provided to demonstrate the tradeoff between energy-efficiency and spectral efficiency.

  7. Adaptive Image Transmission Scheme over Wavelet-Based OFDM System

    Institute of Scientific and Technical Information of China (English)

    GAOXinying; YUANDongfeng; ZHANGHaixia

    2005-01-01

    In this paper an adaptive image transmission scheme is proposed over Wavelet-based OFDM (WOFDM) system with Unequal error protection (UEP) by the design of non-uniform signal constellation in MLC. Two different data division schemes: byte-based and bitbased, are analyzed and compared. Different bits are protected unequally according to their different contribution to the image quality in bit-based data division scheme, which causes UEP combined with this scheme more powerful than that with byte-based scheme. Simulation results demonstrate that image transmission by UEP with bit-based data division scheme presents much higher PSNR values and surprisingly better image quality. Furthermore, by considering the tradeoff of complexity and BER performance, Haar wavelet with the shortest compactly supported filter length is the most suitable one among orthogonal Daubechies wavelet series in our proposed system.

  8. A Multiple-Antenna System for ISM-Band Transmission

    Directory of Open Access Journals (Sweden)

    Rinas J

    2004-01-01

    Full Text Available We present a multiple antenna system for industrial, scientific, and medical (ISM-band transmission (MASI. The hardware demonstrator was developed and realized at our institute. It enables multiple-input multiple-output (MIMO-communication applications and is capable of transmiting arbitrary signals using transmit and receive antennas in parallel. It operates in the 2.4 GHz ISM-band. The hardware concept is introduced and some design specifications are discussed. Using this transmission system, we present some measurement results to show the feasibility of MIMO concepts currently under discussion. The applications include transmit and receive diversity for single carrier and OFDM as well as blind source separation (BSS techniques.

  9. Portable wireless power transmission system for video capsule endoscopy.

    Science.gov (United States)

    Zhiwei, Jia; Guozheng, Yan; Bingquan, Zhu

    2014-10-01

    Wireless power transmission is considered a practical way of overcoming the power shortage of wireless capsule endoscopy (VCE). However, most patients cannot tolerate the long hours of lying in a fixed transmitting coil during diagnosis. To develop a portable wireless power transmission system for VCE, a compact transmitting coil and a portable inverter circuit driven by rechargeable batteries are proposed. The couple coils, optimized considering the stability and safety conditions, are 28 turns of transmitting coil and six strands of receiving coil. The driven circuit is designed according to the portable principle. Experiments show that the integrated system could continuously supply power to a dual-head VCE for more than 8 h at a frame rate of 30 frames per second with resolution of 320 × 240. The portable VCE exhibits potential for clinical applications, but requires further improvement and tests.

  10. Rigorous theoretical derivation of lumped models to transmission line systems

    Institute of Scientific and Technical Information of China (English)

    Zhao Jixiang

    2012-01-01

    By virtue of the negative electric parameter concept,i.e.negative lumped resistance,inductance,conductance and capacitance (N-RLGC),the lumped equivalent models of transmission line systems,including the circuit model,two-port π-network and T-network,are given.We start from the N-segment-ladder-like equivalent networks composed distributed parameters,and achieve the input impedance in the form of a continued fraction.Utilizing the continued fraction theory,the expressions of input impedance are obtained under three kinds of extreme cases,i.e.the load impedances are equal to zero,infinity and characteristic impedance,respectively.When the number of segment N is limited to infinity,they are transformed to lumped elements.Comparison between the distributed model and lumped model of transmission lines,the expression of tanh yd,which is the key term in the transmission line equations,are obtained by RLGC,furthermore,according to input admittance,admittance matrix and ABCD matrix of transmission lines,the lumped equivalent circuit models,π-networks and T-networks have been given.The models are verified in the frequency and time domain,respectively,showing that the models are accurate and efficient.

  11. Short-term repeated corticosterone administration enhances glutamatergic but not GABAergic transmission in the rat motor cortex.

    Science.gov (United States)

    Kula, Joanna; Blasiak, Anna; Czerw, Anna; Tylko, Grzegorz; Sowa, Joanna; Hess, Grzegorz

    2016-04-01

    It has been demonstrated that stress impairs performance of skilled reaching and walking tasks in rats due to the action of glucocorticoids involved in the stress response. Skilled reaching and walking are controlled by the primary motor cortex (M1); however, it is not known whether stress-related impairments in skilled motor tasks are related to functional and/or structural alterations within the M1. We studied the effects of single and repeated injections of corticosterone (twice daily for 7 days) on spontaneous excitatory and inhibitory postsynaptic currents (sEPSCs and sIPSCs) recorded from layer II/III pyramidal neurons in ex vivo slices of the M1, prepared 2 days after the last administration of the hormone. We also measured the density of dendritic spines on pyramidal cells and the protein levels of selected subunits of AMPA, NMDA, and GABAA receptors after repeated corticosterone administration. Repeatedly administered corticosterone induced an increase in the frequency but not in the amplitude of sEPSCs, while a single administration had no effect on the recorded excitatory currents. The frequency and amplitude of sIPSCs as well as the excitability of pyramidal cells were changed neither after single nor after repeated corticosterone administration. Treatment with corticosterone for 7 days did not modify the density of dendritic spines on pyramidal neurons. Corticosterone influenced neither the protein levels of GluA1, GluA2, GluN1, GluN2A, and GluN2B subunits of glutamate receptors nor those of α1, β2, and γ2 subunits of the GABAA receptor. The increase in sEPSCs frequency induced by repeated corticosterone administration faded out within 7 days. These data indicate that prolonged administration of exogenous corticosterone selectively and reversibly enhances glutamatergic, but not GABAergic transmission in the rat motor cortex. Our results suggest that corticosterone treatment results in an enhancement of spontaneous glutamate release from presynaptic

  12. Control strategies for VSC-based HVDC transmission system

    DEFF Research Database (Denmark)

    Stan, Ana-Irina; Stroe, Daniel Ioan; Silva, Rodrigo Da

    2011-01-01

    Throughout this paper the modeling and control of the VSC-based HVDC systems are investigated and described. Two different control methods capable of controlling such systems are proposed. Both developed control strategies are implemented in the dq synchronous reference frame. In order to analyze...... the behavior of the developed VSC-based HVDC transmission system two study cases are carried out using MATLAB/Simulink. The results obtained from simulations show acceptable performances, of the proposed strategies, when changes in the reference parameters are considered. The active power flow between...... the converters is succesfully achieved while, the independent control of active and reactive power is also verified....

  13. Observed reductions in Schistosoma mansoni transmission from large-scale administration of praziquantel in Uganda: a mathematical modelling study.

    Directory of Open Access Journals (Sweden)

    Michael D French

    Full Text Available BACKGROUND: To date schistosomiasis control programmes based on chemotherapy have largely aimed at controlling morbidity in treated individuals rather than at suppressing transmission. In this study, a mathematical modelling approach was used to estimate reductions in the rate of Schistosoma mansoni reinfection following annual mass drug administration (MDA with praziquantel in Uganda over four years (2003-2006. In doing this we aim to elucidate the benefits of MDA in reducing community transmission. METHODS: Age-structured models were fitted to a longitudinal cohort followed up across successive rounds of annual treatment for four years (Baseline: 2003, TREATMENT: 2004-2006; n = 1,764. Instead of modelling contamination, infection and immunity processes separately, these functions were combined in order to estimate a composite force of infection (FOI, i.e., the rate of parasite acquisition by hosts. RESULTS: MDA achieved substantial and statistically significant reductions in the FOI following one round of treatment in areas of low baseline infection intensity, and following two rounds in areas with high and medium intensities. In all areas, the FOI remained suppressed following a third round of treatment. CONCLUSIONS/SIGNIFICANCE: This study represents one of the first attempts to monitor reductions in the FOI within a large-scale MDA schistosomiasis morbidity control programme in sub-Saharan Africa. The results indicate that the Schistosomiasis Control Initiative, as a model for other MDA programmes, is likely exerting a significant ancillary impact on reducing transmission within the community, and may provide health benefits to those who do not receive treatment. The results obtained will have implications for evaluating the cost-effectiveness of schistosomiasis control programmes and the design of monitoring and evaluation approaches in general.

  14. Transmission of order in some unusual dilute systems

    Science.gov (United States)

    Adler, Joan; Palmer, R. G.; Meyer, H.

    1987-03-01

    As a system is diluted, the critical temperature T may fall to zero at a concentration X sub c greater than the percolation concentration, because mere connectivity does not guarantee the transmission of order even at T = 0. Detailed results, including bounds on X sub c, are presented for the three-state Potts antiferromagnet on a triangular lattice and for quadrupolar models of (o-H2)x(p-H2)1-x mixtures on fcc and triangular lattices.

  15. TRANSMISSION OF DATA USING POWER LINE CARRIER COMMUNICATION SYSTEM

    Directory of Open Access Journals (Sweden)

    Jovita Serrao

    2012-11-01

    Full Text Available This paper serves as a general and technical reference to transmission of data using a power line carrier communication system which is a preferred choice over Wireless or other Home Networking technologies due to the ease of installation, availability of AC outlets, higher throughput, low cost, reliability and security. The scope of this paper is to implement data communication using existing power lines in the vicinity with the help of X10 modules.

  16. A GIS-based Power Transmission Management Information System

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    <正>Based on analyzing the shortcomings of electric power enterprise in traditional operation pattern,this paper combines components GIS with the application of management information system,and uses the structure which unifies three layers C/S and B/S.Also,proposed using the GPS intellectualization patrol.This may be useful to guarantees the transmission line’s operation to be safe and stable.

  17. EHV/HV Underground Cable Systems for Power Transmission

    DEFF Research Database (Denmark)

    Bak, Claus Leth

    are to be found. One very good example of this is offshore wind power plants. The current transmission system is laid out in a traditional manner, which is based on the idea of not transporting power over longer distances as the power plants have been located near centres of consumption. It has merely played....... Many interesting research topics are still open, especially with regards to asset management tools....

  18. Comparison of scientific and administrative database management systems

    Science.gov (United States)

    Stoltzfus, J. C.

    1983-01-01

    Some characteristics found to be different for scientific and administrative data bases are identified and some of the corresponding generic requirements for data base management systems (DBMS) are discussed. The requirements discussed are especially stringent for either the scientific or administrative data bases. For some, no commercial DBMS is fully satisfactory, and the data base designer must invent a suitable approach. For others, commercial systems are available with elegant solutions, and a wrong choice would mean an expensive work-around to provide the missing features. It is concluded that selection of a DBMS must be based on the requirements for the information system. There is no unique distinction between scientific and administrative data bases or DBMS. The distinction comes from the logical structure of the data, and understanding the data and their relationships is the key to defining the requirements and selecting an appropriate DBMS for a given set of applications.

  19. Control and Simulation of Continuously Variable Transmission for Electric Transmission System

    Institute of Scientific and Technical Information of China (English)

    张豫南; 葛蕴珊; 马晓军; 臧克茂

    2004-01-01

    According to the study of electric transmission, the concept of the fore and the aft power chain is presented. The control method of continuously variable transmission is established in the aft chain of electric transmission based on brushless DC motor. A fuzzy controller is designed with continuous fuzzy variables and the simulation module of the aft power chain is proved by test. The fuzzy controller controls the process of continuously variable transmission steadily and the acceleration of vehicle is quick according to simulation results. The elementary performance exhibited in the simulation is a foundation for the further study of the electric transmission track vehicle.

  20. Downlink transmission in multi-carrier systems with reduced feedback

    DEFF Research Database (Denmark)

    Wang, Yuanye; Pedersen, Klaus; Sørensen, Troels Bundgaard

    2010-01-01

    in this paper we address the problem of reducing the feedback for the downlink transmission in multi-carrier systems. In these systems multiple Component Carriers (CCs) are aggregated together to form a wide spectrum. Consequently, a large feedback overhead is required to report the channel quality...... information over such a wide bandwidth. We first generalize two existing feedback reduction techniques, and then propose a new one. These techniques use different feedback schemes across the CCs, or allow some CCs to be un-reported, for the purpose of reducing the amount of feedback. Performance...

  1. A multicarrier TDM transmission system for DBS-A

    Science.gov (United States)

    Campanella, S. J.

    1992-03-01

    Satellite communications service for space based broadcasting has been suggested by the National Research Council's Technical Operation's Committee for the Voice of America. The service is referred to as direct broadcast from space-audio (DBS-A). This paper presents a concept incorporating low bit rate source coding for voice and music, digital modulation, forward error correction coding and Viterbi decoding, multiple satellite beams, and multiple carrier time division multiplexed (TDM) transmission to provide a system capable of world wide coverage. The system provides the capability to narrow cast to specific geographically clustered audiences. Emphasis is on the space segment (transmitter) and earth segment (receiver) using the techniques mentioned above.

  2. A novel fiber audio transmission system for secure communication

    Institute of Scientific and Technical Information of China (English)

    SU Ke; JIA Bo

    2005-01-01

    A new,simple and efficient fiber audio transmission method for the long distance secure communication is presented, which performs signal modulation by the strain-optic effects and signal demodulation by the all-fiber interferometer. The interferometer is a truly path-matched device, which eliminates much of the undesirable noise by combining the reference and the sensing arms within the same optical fiber. The sinusoidal signals adopted in the experiment are in a frequency range of 300 HZ-3 400 HZ and of the multi-frequency, and the system shows good capabilities, robust security and maintenance of audio integrity. The device may be applicable in the field of point to point secure communication of 40 kilometer long transmission range.

  3. Building Fit-For-Purpose Land Administration Systems

    DEFF Research Database (Denmark)

    Enemark, Stig; McLaren, Robin; Lemmen, Christiaan

    2016-01-01

    This paper describes the key principles for building sustainable and Fit-For-Purpose (FFP) Land Administration Systems especially in developing countries where often less the 10 per cent of the land and population is included in the formal systems. New solutions are required that can deliver...... security of tenure for all, are affordable and can be quickly developed and incrementally improved over time. The Fit-For-Purpose (FFP) approach to land administration has emerged to meet these simple, but challenging requirements. It is argued that the FFP approach is the only viable solution to solving...... Administration in collaboration with key partners. This paper presents the conceptual outcome of this project. The resulting GLTN publication will be launched at the FIG Working Week, Christchurch, New Zealand, May 2016. The FFP approach has three fundamental characteristics. Firstly there is a focus...

  4. ICT enabled land administration systems for sustainable development

    DEFF Research Database (Denmark)

    Enemark, Stig

    2006-01-01

    This paper analyses the current Land Administration System (LAS) in Denmark with a focus on institutional arrangements, land policies, land information infrastructure, and the four land administration functions: land tenure, land value, land-use, and land development. The analysis, this way, builds...... on the land management paradigm. Some challenges and barriers are identified and the key initiatives for improvement are described. It is concluded that the system works well in the sense that it supports sustainable development through an efficient land market and effective land-use management. The property...... layer (the cadastre) is well integrated as the basis for a land information infrastructure in support of all four land administration functions. Furthermore, the LAS is well tailored for a decentralised approach to land-use management placing the decisionmaking power at regional and especially local...

  5. Power and signal transmission for mobile teleoperated systems

    Energy Technology Data Exchange (ETDEWEB)

    Morris, A.C. Jr.; Hamel, W.R.

    1985-01-01

    Appropriate means must be furnished for supplying power and for sending controlling commands to mobile teleoperated systems. Because a sizable number of possibilities are available for such applications, methods used in designing both the power and communications systems built into mobile vehicles that serve in radiological emergencies must be carefully selected. This paper describes a number of umbilical, on-board, and wireless systems used in tranmitting power that are available for mobile teleoperator services. The pros and cons of selecting appropriate methods from a list of possible communication systems (wired, fiber optic, and radio frequency) are also examined. Moreover, hybrid systems combining wireless power transmissions with command-information signals are also possible.

  6. Lightning location system supervising Swedish power transmission network

    Science.gov (United States)

    Melin, Stefan A.

    1991-01-01

    For electric utilities, the ability to prevent or minimize lightning damage on personnel and power systems is of great importance. Therefore, the Swedish State Power Board, has been using data since 1983 from a nationwide lightning location system (LLS) for accurately locating lightning ground strikes. Lightning data is distributed and presented on color graphic displays at regional power network control centers as well as at the national power system control center for optimal data use. The main objectives for use of LLS data are: supervising the power system for optimal and safe use of the transmission and generating capacity during periods of thunderstorms; warning service to maintenance and service crews at power line and substations to end operations hazardous when lightning; rapid positioning of emergency crews to locate network damage at areas of detected lightning; and post analysis of power outages and transmission faults in relation to lightning, using archived lightning data for determination of appropriate design and insulation levels of equipment. Staff have found LLS data useful and economically justified since the availability of power system has increased as well as level of personnel safety.

  7. Performance analysis of a model-sized superconducting DC transmission system based VSC-HVDC transmission technologies using RTDS

    Science.gov (United States)

    Dinh, Minh-Chau; Ju, Chang-Hyeon; Kim, Sung-Kyu; Kim, Jin-Geun; Park, Minwon; Yu, In-Keun

    2012-08-01

    The combination of a high temperature superconducting DC power cable and a voltage source converter based HVDC (VSC-HVDC) creates a new option for transmitting power with multiple collection and distribution points for long distance and bulk power transmissions. It offers some greater advantages compared with HVAC or conventional HVDC transmission systems, and it is well suited for the grid integration of renewable energy sources in existing distribution or transmission systems. For this reason, a superconducting DC transmission system based HVDC transmission technologies is planned to be set up in the Jeju power system, Korea. Before applying this system to a real power system on Jeju Island, system analysis should be performed through a real time test. In this paper, a model-sized superconducting VSC-HVDC system, which consists of a small model-sized VSC-HVDC connected to a 2 m YBCO HTS DC model cable, is implemented. The authors have performed the real-time simulation method that incorporates the model-sized superconducting VSC-HVDC system into the simulated Jeju power system using Real Time Digital Simulator (RTDS). The performance analysis of the superconducting VSC-HVDC systems has been verified by the proposed test platform and the results were discussed in detail.

  8. International Conference on Harmonisation; guidance on data elements for transmission of individual case safety reports; availability. Notice. Food and Drug Administration, HHS.

    Science.gov (United States)

    1998-01-15

    The Food and Drug Administration (FDA) is publishing a guidance entitled "E2B Data Elements for Transmission of Individual Case Safety Reports." The guidance was prepared under the auspices of the International Conference on Harmonisation of Technical Requirements for Registration of Pharmaceuticals for Human Use (ICH). The guidance is intended to facilitate the standardization of the data elements for the transmission of individual case safety reports for both preapproval and postapproval reporting periods.

  9. Building Fit-for-Purpose Land Administration Systems

    DEFF Research Database (Denmark)

    Enemark, Stig; Bell, Keith; Lemmen, Christiaan;

    2014-01-01

    Arguably sound land governance is the key to achieve sustainable development and to support the global agenda set by adoption of the Millennium Development Goals (MDGs). The operational component of land governance is the country specific land administration systems dealing with the four key func...

  10. Security administration plan for HANDI 2000 business management system

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, D.

    1998-09-29

    This document encompasses and standardizes the integrated approach for security within the PP and Ps applications, It also identifies the security tools and methods to be used. The Security Administration Plan becomes effective as of this document`s acceptance and will provide guidance through implementation efforts and, as a ``living document`` will support the operations and maintenance of the system.

  11. Blending Administrative and Academic Units in a Systems Application.

    Science.gov (United States)

    Fowler, George C.; Rose, Warren

    1981-01-01

    Describes how the business computing science department at Texas A. & M. University devised a computerized information system about students for the university's new medical school. Discusses the roles of faculty members and administrators in the project and the design, implementation, and evaluation of the project. (Author/RW)

  12. Adaptive transmission schemes for MISO spectrum sharing systems

    KAUST Repository

    Bouida, Zied

    2013-06-01

    We propose three adaptive transmission techniques aiming to maximize the capacity of a multiple-input-single-output (MISO) secondary system under the scenario of an underlay cognitive radio network. In the first scheme, namely the best antenna selection (BAS) scheme, the antenna maximizing the capacity of the secondary link is used for transmission. We then propose an orthogonal space time bloc code (OSTBC) transmission scheme using the Alamouti scheme with transmit antenna selection (TAS), namely the TAS/STBC scheme. The performance improvement offered by this scheme comes at the expense of an increased complexity and delay when compared to the BAS scheme. As a compromise between these schemes, we propose a hybrid scheme using BAS when only one antenna verifies the interference condition and TAS/STBC when two or more antennas are illegible for communication. We first derive closed-form expressions of the statistics of the received signal-to-interference-and-noise ratio (SINR) at the secondary receiver (SR). These results are then used to analyze the performance of the proposed techniques in terms of the average spectral efficiency, the average number of transmit antennas, and the average bit error rate (BER). This performance is then illustrated via selected numerical examples. © 2013 IEEE.

  13. The transmission link of CAPS navigation and communication system

    Institute of Scientific and Technical Information of China (English)

    CUI JunXia; SHI HuLi; CHEN JiBin; PEI Jun

    2009-01-01

    The Chinese Area Positioning System (CAPS) is based on communication satellites with integrated oapability,whioh is different from the Global Positioning System (GPS),the International Maritime Satellite Organization (Inmarsat) and so on.CAPS works at G-band,and its navigation information ie not directly generated from the satellite,but from the master control station on the ground and transmitted to users via the satellite.The slightly inclined geostationary-satellite orbit (SIGSO) satellites are adopted in CAPS.All of these increase the difficulty in the design of the system and terminals.In this paper,the authors study the CAPS oonfiguration parameters of the navigation master control station,information transmission capability,and the selection of the antenna aperture of the communication oenter station,as well as the impact of satellite parameters on the whole communication system from the perspective of the transmission link budget.The conclusion of availability of the GAPS navigation system is achieved.The results show that the GAPS inbound communication system forms a new low-data-rate satellite communicaUon system,which can accommodate mass communication termihale with the transmission rate of no more than 1 kbps for every terminal.The communication center station should be configured with a large-aperture antenna (about 10--15 m); spread spectrum communication technology should be used with the spreading gain as high as about 40 dB; reduction of the satellite transponder gain attenuation is beneficial to improving the signal-to-noise ratio of the system,with the attenuation value of 0 or 2 dB as the best choice.The fact that the GAPS navigation system has been checked and aooepted by the experts and the operation is stable till now larifies the rationality of the analysis results.The fact that a variety of experiments and applications of the satellite communication system designed according to the findings in this paper have been successfully carried out

  14. Artificial intelligence in the service of system administrators

    CERN Document Server

    Haen, Christophe; Bonaccorsi, E; Neufeld, N

    2012-01-01

    The LHCb online system relies on a large and heterogeneous IT infrastructure made from thousands of servers on which many different applications are running. They run a great variety of tasks: critical ones such as data taking and secondary ones like web servers. The administration of such a system and making sure it is working properly represents a very important workload for the small expert-operator team. Research has been performed to try to automatize (some) system administration tasks, starting in 2001 when IBM defined the so-called self objectives supposed to lead to autonomic computing. In this context, we present a framework that makes use of artificial intelligence and machine learning to monitor and diagnose at a low level and in a non intrusive way Linux-based systems and their interaction with software. Moreover, the multi agent approach we use, coupled with an object oriented paradigm architecture should increase our learning speed a lot and highlight relations between problems.

  15. Decline in lymphatic filariasis transmission with annual mass drug administration using DEC with and without albendazole over a 10year period in India.

    Science.gov (United States)

    Sunish, I P; Kalimuthu, M; Rajendran, R; Munirathinam, A; Ashok Kumar, V; Nagaraj, J; Tyagi, B K

    2015-02-01

    The National Programme for the Elimination of Lymphatic Filariasis is underway in the endemic districts of Tamil Nadu State, South India, since 2001. Annual mass drug administration (MDA) was carried out by the state health department to all eligible individuals. The impact of MDAs on transmission parameters was evaluated in 2 revenue blocks, viz, one with DEC alone and the other with a combination of albendazole. After 10 years with 6 annual MDAs, the transmission indices reached low levels in both treatment arms, but still persisted. However, the DEC alone arm showed higher transmission rates, compared to the DEC+ALB arm. Few villages which demonstrated persistent transmission need to be targeted with an additional control measure viz, vector control, to achieve LF elimination. It is evident from the 10 year period of the study that inclusion of albendazole along with DEC has significantly reduced the transmission indices to almost nil level, as compared to DEC alone.

  16. Redesign and modernization of radioactive waste administration systems in Ukraine

    Energy Technology Data Exchange (ETDEWEB)

    Nieder-Westermann, Gerald H.; Walther, Thorsten; Krone, Juergen [DBE Technology GmbH, Peine (Germany)

    2016-06-15

    The European Commission (EC) has undertaken a series of projects to render assistance to Ukraine in modernizing and redesigning the Ukrainian approach to the administration, management and ultimately disposal of all forms of radioactive waste, including waste associated with the Chornobyl accident as well as waste generated as part of the Ukrainian energy infrastructure and from industrial and medical applications. One of the most recently completed projects focused on modernizing Ukraine's management and administrative systems responsible for the disposal of radioactive waste.

  17. Multi-core Fibers in Submarine Networks for High-Capacity Undersea Transmission Systems

    DEFF Research Database (Denmark)

    Nooruzzaman, Md; Morioka, Toshio

    2017-01-01

    Application of multi-core fibers in undersea networks for high-capacity submarine transmission systems is studied. It is demonstrated how different architectures of submerged branching unit affect network component counts in long-haul undersea transmission systems......Application of multi-core fibers in undersea networks for high-capacity submarine transmission systems is studied. It is demonstrated how different architectures of submerged branching unit affect network component counts in long-haul undersea transmission systems...

  18. Generation and transmission of greenhouse gases in river system

    Institute of Scientific and Technical Information of China (English)

    ZHANG Yu; WANG Shu-bo

    2016-01-01

    The research progress on the current domestic and foreign about river water system of the greenhouse gas methane(CH4), and nitrous oxide(N2O) generation, transmission and release mechanism are reviewed in this paper. At present, at home and abroad of river water system of methane production and release of the driving factors and mechanism has been basically clear, but the N2O production mechanism is not clear, multi factor interaction of river water system of N2O production and release of complex, in different regions and time of result differences. The calculation of water flux of N2O river discharge coefficient of river IPCC released based on N2O, the release amount may underestimate the river water N2O.

  19. A portable wireless power transmission system for video capsule endoscopes.

    Science.gov (United States)

    Shi, Yu; Yan, Guozheng; Zhu, Bingquan; Liu, Gang

    2015-01-01

    Wireless power transmission (WPT) technology can solve the energy shortage problem of the video capsule endoscope (VCE) powered by button batteries, but the fixed platform limited its clinical application. This paper presents a portable WPT system for VCE. Besides portability, power transfer efficiency and stability are considered as the main indexes of optimization design of the system, which consists of the transmitting coil structure, portable control box, operating frequency, magnetic core and winding of receiving coil. Upon the above principles, the correlation parameters are measured, compared and chosen. Finally, through experiments on the platform, the methods are tested and evaluated. In the gastrointestinal tract of small pig, the VCE is supplied with sufficient energy by the WPT system, and the energy conversion efficiency is 2.8%. The video obtained is clear with a resolution of 320×240 and a frame rate of 30 frames per second. The experiments verify the feasibility of design scheme, and further improvement direction is discussed.

  20. Carbon footprint of the Danish electricity transmission and distribution systems

    DEFF Research Database (Denmark)

    Turconi, Roberto; Astrup, Thomas Fruergaard

    &D) will likely grow. Several studies are available on renewable energy technologies, but only a few on transmission of electricity, and none on its distribution. This study provides life cycle inventory data for electricity distribution networks, and a life cycle GHG accounting of the Danish T&D networks....... The purpose was to evaluate the potential importance of environmental impacts associated with T&D in current and future electricity systems. Including the emissions from electricity T&D is needed to provide a full carbon footprint of electricity systems, and is essential to properly assess the environmental...... consequences of potential changes in an electricity system. So far, the basis for such assessments has not been available. The functional unit of this study was the delivery of one kWh of electricity in Denmark. The 2010 Danish electricity T&D networks were modeled, including power lines, transformers...

  1. 75 FR 3223 - California Independent System Operator Corporation; Midwest Independent Transmission System...

    Science.gov (United States)

    2010-01-20

    ... a subsequent notice. \\1\\ Wholesale Competition in Regions with Organized Electric Market, Order No... the responsiveness of regional transmission organizations (RTOs) and independent system operators... lead to decisions that do not adequately consider the price of electricity to residential consumers....

  2. A flexible computerized system for environmental data acquisition and transmission

    Science.gov (United States)

    Zappalà, G.

    2009-04-01

    In recent years increasing importance has been addressed to the knowledge of the marine environment, either to help detecting and understanding global climate change phenomena, or to protect and preserve those coastal areas, where multiple interests converge (linked to the tourism, recreational or productive activities…) and which suffer greater impact from anthropogenic activities; this has in turn stimulated the start of research programs devoted to the monitoring and surveillance of these particular zones, coupling the needs for knowledge, sustainable development and exploitation of natural resources. There is an increasing need to have data available in real time or near real time in order to intervene in emergency situations. Cabled or wireless data transmission can be used. The first allows the transmission of a higher amount of data only in coastal sites, while the second gives a bigger flexibility in terms of application to different environments; more, using mobile phone services (either terrestrial or satellite), it is possible to allocate the data centre in the most convenient place, without any need of proximity to the sea. Traditional oceanographic techniques, based on ship surveys, hardly fit the needs of operational oceanography, because of their high cost and fragmentary nature, both in spatial and temporal domains. To obtain a good synopticity, it is necessary to complement traditional ship observations with measurements from fixed stations (buoys moored in sites chosen to be representative of wider areas, or to constitute a sentinel against the arrival of pollutants), satellite observations, use of ships of opportunity and of newly developed instruments, like the gliders, or towed sliding devices, like the SAVE. Modern instruments rely on an electronic heart; an integrated hardware-software system developed in Messina is here presented, used in various versions to control data acquisition and transmission on buoys or on ship

  3. Nonlinear Vibroimpact Characteristics of a Planetary Gear Transmission System

    Directory of Open Access Journals (Sweden)

    Jianxing Zhou

    2016-01-01

    Full Text Available In order to research the vibroimpact characteristics of a planetary gear transmission system under high speed and lightly loaded conditions, a new modeling method is proposed. In the modeling process, linear spring was used to simulate gear mesh elasticity under heavy load cases, and Hertz contact theory was used to calculate the contact force of gear pair under light load cases. Then, effects of the working conditions on the system vibroimpact characteristics are analyzed. The results show that, with input speed growing, the mesh force produced obvious fluctuations on the resonance frequencies of the sun gear and carrier torsion vibration, ring gear’s transverse vibration under the heavy load. Under light load condition, the collision vibration occurs in the gear pair; the changing trend of the contact force shows strongly nonlinear characteristics. The time of mesh-apart in gears pair decreases gradually as the load is increased; until it reaches collision vibration threshold value, the gear pair is no longer mesh-apart. With increasing of the input speed, the time of mesh-apart is decreased gradually; the fluctuation amplitude of contact force shows a linearly increasing trend. The study provides useful theoretical guideline for planetary gear transmission low-noise design.

  4. Fast Decoupled Power Flow for Power System with High Voltage Direct Current Transmission Line System

    Directory of Open Access Journals (Sweden)

    Prechanon Kumkratug

    2010-01-01

    Full Text Available Problem statement: High voltage direct current transmission line system has been widely applied for control power flow in power system. The power flow analysis was the one of powerful tools by which the power system equipped was analyzed both for planning and operation strategies. Approach: This study presented the method to analyze power flow of power system consisted of HVDC system. HVDC was modeled as the complex power injections. The presented complex power injected was incorporated into the existing power flow program based on fast decoupled method. The presented method was tested on the multimachine power system. Results: The transmission line loss of the system with and without HVDC was compared. Conclusion: From the simulation results, the HVDC can reduce transmission line loss of power system.

  5. The Effect Analysis of Strain Rate on Power Transmission Tower-Line System under Seismic Excitation

    OpenAIRE

    Li Tian; Wenming Wang; Hui Qian

    2014-01-01

    The effect analysis of strain rate on power transmission tower-line system under seismic excitation is studied in this paper. A three-dimensional finite element model of a transmission tower-line system is created based on a real project. Using theoretical analysis and numerical simulation, incremental dynamic analysis of the power transmission tower-line system is conducted to investigate the effect of strain rate on the nonlinear responses of the transmission tower and line. The results sho...

  6. Optimisation of power transmission systems using a discrete Tabu Search method

    OpenAIRE

    Connor, Andy M.; Tilley, Derek G.

    2016-01-01

    This paper presents a brief description of the Tabu Search method and shows how it can be applied to two different power transmission systems. Examples are presented from two transmission systems. In the first example a mechanical transmission system is considered. A four bar mechanism is synthesised in order to produce a desired output motion. The second example is a hydrostatic transmission operating under closed loop control in order to maintain a constant operating speed as the loading co...

  7. Analysis of torsional vibration in an electromechanical transmission system

    Directory of Open Access Journals (Sweden)

    Kai Chen

    2016-06-01

    Full Text Available Aiming at the torsional vibration in the electromechanical transmission system, this article introduces the active vibration method and analyzes the vibration characteristics on the condition of the external excitation, and then, the condition of the permanent magnetic synchronous motor parameter is obtained. In the braking energy recovery working condition, the permanent magnetic synchronous motor is operated in generator mode and is subjected to power control, this cause it to produce negative effect of damping. Negative effect of damping leads to the increasing torsional vibration. Then, the improved power control strategy is introduced to reduce the vibration. Computer simulations are used to demonstrate the active vibration method and the effectiveness of the proposed control strategy, which provides reference for the design of electromechanical systems in the hybrid electrical vehicles.

  8. Application of DSP in the image transmission system

    Science.gov (United States)

    Gui, Feng; Wei, LinQi

    2006-05-01

    A scheme to realize static image and video code and decode based on TI DSP chip TMS320C6416 was proposed in this paper, and a reliable image transmission system was developed. According to the application demand, the software has six major modules: (1) initialization of DSP chip and other hardware; (2) video acquisition and input control program; (3) serial port communicating program; (4) RAM storage and communicating program that applies and releases the token-ring; (5) video reconstruct and output control; (6) the major parts of the software, encoding and decoding program, in which wavelet was applied first, then run length coding and Huffman coding were carried out, the image or video could had balance resolution and better visual effect by adaptive processing, in the decoding parts, the reverse operation were executed. After the system line up debugging was carried out, a satisfying result was reached: the comparatively high compression rate, preferable image quality and relatively real-time result.

  9. Dynamic security risk assessment and optimization of power transmission system

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    The paper presents a practical dynamic security region (PDSR) based dynamic security risk assessment and optimization model for power transmission system. The cost of comprehensive security control and the influence of uncertainties of power injections are considered in the model of dynamic security risk assessment. The transient stability constraints and uncertainties of power injections can be considered easily by PDSR in form of hyper-box. A method to define and classify contingency set is presented, and a risk control optimization model is given which takes total dynamic insecurity risk as the objective function for a dominant con-tingency set. An optimal solution of dynamic insecurity risk is obtained by opti-mizing preventive and emergency control cost and contingency set decomposition. The effectiveness of this model has been proved by test results on the New Eng-land 10-genarator 39-bus system.

  10. Best Practices for Land Administration Systems in Developing Countries

    OpenAIRE

    2000-01-01

    This paper is a post-conference summary of the International Conference on Land Policy Reform that took place in Jarkarta from July 25-27, 2000. The paper concerns best practice in land administration systems. While the paper is focussed on world's best practice, it does so in the context of developing and emerging industrial countries such as Indonesia which have diverse land tenure relat...

  11. Risk measures for power failures in transmission systems

    Science.gov (United States)

    Cassidy, Alex; Feinstein, Zachary; Nehorai, Arye

    2016-11-01

    We present a novel framework for evaluating the risk of failures in power transmission systems. We use the concept of systemic risk measures from the financial mathematics literature with models of power system failures in order to quantify the risk of the entire power system for design and comparative purposes. The proposed risk measures provide the collection of capacity vectors for the components in the system that lead to acceptable outcomes. Keys to the formulation of our measures of risk are two elements: a model of system behavior that provides the (distribution of) outcomes based on component capacities and an acceptability criterion that determines whether a (random) outcome is acceptable from an aggregated point of view. We examine the effects of altering the line capacities on energy not served under a variety of networks, flow manipulation methods, load shedding schemes, and load profiles using Monte Carlo simulations. Our results provide a quantitative comparison of the performance of these schemes, measured by the required line capacity. These results provide more complete descriptions of the risks of power failures than the previous, one-dimensional metrics.

  12. Toroidal Continuously Variable Transmission Systems: Terminology and Present Studies

    Directory of Open Access Journals (Sweden)

    Ahmet YILDIZ

    2014-04-01

    Full Text Available The use of continuously variable transmission systems in many different areas such as aerospace, robotics, machinery and automotive industries as an alternative to conventional speed changers with constant ratio becomes widely.Especially in the automotive industry, these systems have been used increasingly, since they enable that internal combustion engines in vehicles run at optimal speeds, and consequently provide considerable fuel savings and therefore lower emission values and also they provide powerful acceleration and quiet working. CVT systems have several constructive variants such as belted, chained, balled, toroidal etc. In this paper, toroidal CVT systems based on elastohydrodynamic principles are concerned with, and fundamental works of last two decades in this field are reviewed. However, the relevant terminology and dynamics along with the control of these systems are briefly treated for better understanding of the literature mentioned. Attention is drawn to the lack of some significant issues in present research works, and potential future works are pointed out. This paper, to the authors’ knowledge, will be the first review on toroidal CVT systems in Turkish literature

  13. Analysis the Performance of Coded WSK-DWDM Transmission System

    Directory of Open Access Journals (Sweden)

    Bobby Barua

    2012-12-01

    Full Text Available Dense Wavelength Division Multiplexing (DWDM is the system with more than eight active wavelengths per fiber. Again high data rates as well as long spans between amplifiers in a chain require high optical power per channel to satisfy the signal to noise ratio (SNR requirements. So the DWDM systems with long repeater-less spans, the simultaneous requirements of high launched power and low dispersion fibers lead to the generation of new waves by four-wave mixing (FWM, which degrades the performance of a multi-channel transmission system. Several methods have been proposed to mitigate the effect of FWM crosstalk. All these works are performed considering only binary WSK scheme. Although M-ary WSK (M>2 schemes have higher spectral efficiency than binary WSK system. Again, the BER performances for M-ary WDM system are not satisfactory with the effect of FWM. Therefore, in this paper we include the effect of FWM on the performance of an M-ary WDM system and try to mitigate the effect by employing the energy efficient convolution code in a normal dispersive fiber as well as in a dispersion shifted fiber (DSF.

  14. Risk measures for power failures in transmission systems.

    Science.gov (United States)

    Cassidy, Alex; Feinstein, Zachary; Nehorai, Arye

    2016-11-01

    We present a novel framework for evaluating the risk of failures in power transmission systems. We use the concept of systemic risk measures from the financial mathematics literature with models of power system failures in order to quantify the risk of the entire power system for design and comparative purposes. The proposed risk measures provide the collection of capacity vectors for the components in the system that lead to acceptable outcomes. Keys to the formulation of our measures of risk are two elements: a model of system behavior that provides the (distribution of) outcomes based on component capacities and an acceptability criterion that determines whether a (random) outcome is acceptable from an aggregated point of view. We examine the effects of altering the line capacities on energy not served under a variety of networks, flow manipulation methods, load shedding schemes, and load profiles using Monte Carlo simulations. Our results provide a quantitative comparison of the performance of these schemes, measured by the required line capacity. These results provide more complete descriptions of the risks of power failures than the previous, one-dimensional metrics.

  15. Phronesis, a diagnosis and recovery tool for system administrators

    CERN Document Server

    Haen, Christophe; Neufeld, Niko

    The administration of a large computer infrastructure is a great challenge in many aspects and requires experts in various domains to be successful. One criterion to which the users of a data center are directly exposed is the availability of the infrastructure. A high availability comes at the cost of constant and performant monitoring solutions as well as experts ready to diagnose and solve the problems. It is unfortunately not always possible to have an expert team constantly on site. This work presents a tool which is meant to support system administrators in their tasks by diagnosing problems, offering recovery solutions, and acting as a history and knowledge database. We will first detail what large data centers are composed of and what are the various competences that are required in order to successfully administrate them. This will lead us to consider the problems that are traditionally encountered by the administrators. Those problems are at the source of this project, and we will define our goals f...

  16. Transmission of multiple system atrophy prions to transgenic mice.

    Science.gov (United States)

    Watts, Joel C; Giles, Kurt; Oehler, Abby; Middleton, Lefkos; Dexter, David T; Gentleman, Steve M; DeArmond, Stephen J; Prusiner, Stanley B

    2013-11-26

    Prions are proteins that adopt alternative conformations, which become self-propagating. Increasing evidence argues that prions feature in the synucleinopathies that include Parkinson's disease, Lewy body dementia, and multiple system atrophy (MSA). Although TgM83(+/+) mice homozygous for a mutant A53T α-synuclein transgene begin developing CNS dysfunction spontaneously at ∼10 mo of age, uninoculated TgM83(+/-) mice (hemizygous for the transgene) remain healthy. To determine whether MSA brains contain α-synuclein prions, we inoculated the TgM83(+/-) mice with brain homogenates from two pathologically confirmed MSA cases. Inoculated TgM83(+/-) mice developed progressive signs of neurologic disease with an incubation period of ∼100 d, whereas the same mice inoculated with brain homogenates from spontaneously ill TgM83(+/+) mice developed neurologic dysfunction in ∼210 d. Brains of MSA-inoculated mice exhibited prominent astrocytic gliosis and microglial activation as well as widespread deposits of phosphorylated α-synuclein that were proteinase K sensitive, detergent insoluble, and formic acid extractable. Our results provide compelling evidence that α-synuclein aggregates formed in the brains of MSA patients are transmissible and, as such, are prions. The MSA prion represents a unique human pathogen that is lethal upon transmission to Tg mice and as such, is reminiscent of the prion causing kuru, which was transmitted to chimpanzees nearly 5 decades ago.

  17. Spatial analysis in PGPB's risk administration system for pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Garcia, L.R.C.S.; Mendoza, J.L.M.; Betancourt, E.R. [Pemex Gas and Petrochemical Basics, Huasteca (Mexico); Polanco, R.P. [Petroleos Mexicanos, Huasteca (Mexico)

    2004-07-01

    Pemex Gas and Petrochemical Basics (PGPB) has been using Bass Trigon's Integrity Assessment Program (IAP) for risk administration. The software includes a risk administration system for pipelines (RASP), making it possible to identify and evaluate risks that could affect the transportation capacity of the petrochemical, liquefied petroleum gas and natural gas transmission system. The pipeline division of PGPB uses a geographic information system (GIS) called the facilities and assets information system (FAIS) for maintenance of its pipelines, as well as the design, construction and operation of pumping and compression stations. Some specific applications using the integrated FAIS and RASP system were presented to demonstrate risk assessment data analysis and their consequences. In particular, it described how PGPB used FAIS to analyse RASP data to decide if a liquefied petroleum gas terminal should change location. RASP considers over 200 variables that contribute to risk factors for external and internal corrosion, design and materials, third parties, ground movement and system operation. The spatial analysis system proved effective in supporting decision making, preventing accidents, and developing emergency plans. 4 refs., 5 tabs., 13 figs.

  18. Vibration and noise analysis of a gear transmission system

    Science.gov (United States)

    Choy, F. K.; Qian, W.; Zakrajsek, J. J.; Oswald, F. B.

    1993-01-01

    This paper presents a comprehensive procedure to predict both the vibration and noise generated by a gear transmission system under normal operating conditions. The gearbox vibrations were obtained from both numerical simulation and experimental studies using a gear noise test rig. In addition, the noise generated by the gearbox vibrations was recorded during the experimental testing. A numerical method was used to develop linear relationships between the gearbox vibration and the generated noise. The hypercoherence function is introduced to correlate the nonlinear relationship between the fundamental noise frequency and its harmonics. A numerical procedure was developed using both the linear and nonlinear relationships generated from the experimental data to predict noise resulting from the gearbox vibrations. The application of this methodology is demonstrated by comparing the numerical and experimental results from the gear noise test rig.

  19. Vibration Signature Analysis of a Faulted Gear Transmission System

    Science.gov (United States)

    Choy, F. K.; Huang, S.; Zakrajsek, J. J.; Handschuh, R. F.; Townsend, D. P.

    1996-01-01

    A comprehensive procedure in predicting faults in gear transmission systems under normal operating conditions is presented. Experimental data were obtained from a spiral bevel gear fatigue test rig at NASA/Lewis. Time-synchronous-averaged vibration data were recorded throughout the test as the fault progressed from a small single pit to severe pitting over several teeth, and finally tooth fracture. A numerical procedure based on the Wigner-Ville distribution was used to examine the time-averaged vibration data. Results from the Wigner-Ville procedure are compared to results from a variety of signal analysis techniques that include time-domain analysis methods and frequency analysis methods. Using photographs of the gear tooth at various stages of damage, the limitations and accuracy of the various techniques are compared and discussed. Conclusions are drawn from the comparison of the different approaches as well as the applicability of the Wigner-Ville method in predicting gear faults.

  20. On multiuser switched diversity transmission for spectrum sharing systems

    KAUST Repository

    Qaraqe, Marwa

    2012-01-01

    In this paper, we develop multiuser access schemes for spectrum sharing systems whereby secondary users share the spectrum with primary users. In particular, we devise two schemes for selecting the user among those that satisfy the interference constraints and achieve an acceptable signal-to-noise ratio (SNR) level. The first scheme selects the user with the maximum SNR at the receiver, whereas in the second scheme the users are scanned in a sequential manner until an acceptable user is found. In addition, we consider two power adaptive settings. In the on/off power adaptive setting, the users transmit based on whether the interference constraint is met or not while in the full power adaptive setting, the users vary their transmission power to satisfy the interference constraint. Finally, we present numerical results of our proposed algorithms where we show the trade-off between the average spectral efficiency and average feedback load of both schemes. © 2012 ICST.

  1. Gas data transmission system by satellite telephone; Systeme de transmission de donnees sur le gaz utilisant le telephone par satellite

    Energy Technology Data Exchange (ETDEWEB)

    Ogasawara, S.; Tanji, A. [Dengineer Co., Ltd (Japan); Akiyama, S. [Buyo Gas Company (Japan)

    2000-07-01

    Dengineer Co., Ltd. and Buyo Gas Co., Ltd. had been developing and using the data and alarm transmission system by public telephone since 1984, that was first practical use in Japan. It is very important for business management that adjusts the production value of gas by measuring gas pressures in each governor. Also, it is indispensable to know the accident of gas leakage or abnormal gas pressure quickly. But this convenient system is not spread yet in Japanese market cause of the following reasons. - Take time and cost for installation of terminal station. - Terminal station is apt to damage by thunder. - Big disaster must stop working this system. In order to solve those problems, we have developed and tested the system organized of the satellite telephone system and solar cells for power. This system will be very useful for wide place, not only Japanese market but also the area, which has no electricity and phone. Also, it will be convenient for international rescue as is able to access it from the foreign countries. (authors)

  2. Transmission imaging for integrated PET-MR systems.

    Science.gov (United States)

    Bowen, Spencer L; Fuin, Niccolò; Levine, Michael A; Catana, Ciprian

    2016-08-07

    Attenuation correction for PET-MR systems continues to be a challenging problem, particularly for body regions outside the head. The simultaneous acquisition of transmission scan based μ-maps and MR images on integrated PET-MR systems may significantly increase the performance of and offer validation for new MR-based μ-map algorithms. For the Biograph mMR (Siemens Healthcare), however, use of conventional transmission schemes is not practical as the patient table and relatively small diameter scanner bore significantly restrict radioactive source motion and limit source placement. We propose a method for emission-free coincidence transmission imaging on the Biograph mMR. The intended application is not for routine subject imaging, but rather to improve and validate MR-based μ-map algorithms; particularly for patient implant and scanner hardware attenuation correction. In this study we optimized source geometry and assessed the method's performance with Monte Carlo simulations and phantom scans. We utilized a Bayesian reconstruction algorithm, which directly generates μ-map estimates from multiple bed positions, combined with a robust scatter correction method. For simulations with a pelvis phantom a single torus produced peak noise equivalent count rates (34.8 kcps) dramatically larger than a full axial length ring (11.32 kcps) and conventional rotating source configurations. Bias in reconstructed μ-maps for head and pelvis simulations was  ⩽4% for soft tissue and  ⩽11% for bone ROIs. An implementation of the single torus source was filled with (18)F-fluorodeoxyglucose and the proposed method quantified for several test cases alone or in comparison with CT-derived μ-maps. A volume average of 0.095 cm(-1) was recorded for an experimental uniform cylinder phantom scan, while a bias of  <2% was measured for the cortical bone equivalent insert of the multi-compartment phantom. Single torus μ-maps of a hip implant phantom showed significantly

  3. Transmission imaging for integrated PET-MR systems

    Science.gov (United States)

    Bowen, Spencer L.; Fuin, Niccolò; Levine, Michael A.; Catana, Ciprian

    2016-08-01

    Attenuation correction for PET-MR systems continues to be a challenging problem, particularly for body regions outside the head. The simultaneous acquisition of transmission scan based μ-maps and MR images on integrated PET-MR systems may significantly increase the performance of and offer validation for new MR-based μ-map algorithms. For the Biograph mMR (Siemens Healthcare), however, use of conventional transmission schemes is not practical as the patient table and relatively small diameter scanner bore significantly restrict radioactive source motion and limit source placement. We propose a method for emission-free coincidence transmission imaging on the Biograph mMR. The intended application is not for routine subject imaging, but rather to improve and validate MR-based μ-map algorithms; particularly for patient implant and scanner hardware attenuation correction. In this study we optimized source geometry and assessed the method’s performance with Monte Carlo simulations and phantom scans. We utilized a Bayesian reconstruction algorithm, which directly generates μ-map estimates from multiple bed positions, combined with a robust scatter correction method. For simulations with a pelvis phantom a single torus produced peak noise equivalent count rates (34.8 kcps) dramatically larger than a full axial length ring (11.32 kcps) and conventional rotating source configurations. Bias in reconstructed μ-maps for head and pelvis simulations was  ⩽4% for soft tissue and  ⩽11% for bone ROIs. An implementation of the single torus source was filled with 18F-fluorodeoxyglucose and the proposed method quantified for several test cases alone or in comparison with CT-derived μ-maps. A volume average of 0.095 cm-1 was recorded for an experimental uniform cylinder phantom scan, while a bias of  translation of the patient table to perform complete tomographic sampling, generated highly quantitative measured μ-maps and is expected to produce images with

  4. Band gap transmission in periodic bistable mechanical systems

    Science.gov (United States)

    Frazier, Michael J.; Kochmann, Dennis M.

    2017-02-01

    We theoretically and numerically investigate the supratransmission phenomenon in discrete, nonlinear systems containing bistable elements. While linear waves cannot propagate within the band gaps of periodic structures, supratransmission allows large-amplitude waves to transmit energy through the band gap. For systems lacking bistability, the threshold amplitude for such energy transmission at a given frequency in the linear band gap is fixed. We show that the topological transitions due to bistability provide an avenue for switching the threshold amplitude between two well-separated values. Moreover, this versatility is achieved while leaving the linear dispersion properties of the system essentially unchanged. Interestingly, the behavior changes when an elastic chain is coupled to bistable resonators (in an extension of the well-studied linear locally resonant metamaterials). Here, we show that a fraction of the injected energy is confined near the boundary due to the resonators, providing a means of regulating the otherwise unrestrained energy flow due to supratransmission. Together, the results illustrate new means of controlling nonlinear wave propagation and energy transport in systems having multi-stable elements.

  5. Self-powered system with wireless data transmission.

    Science.gov (United States)

    Hu, Youfan; Zhang, Yan; Xu, Chen; Lin, Long; Snyder, Robert L; Wang, Zhong Lin

    2011-06-08

    We demonstrate the first self-powered system driven by a nanogenerator (NG) that works wirelessly and independently for long-distance data transmission. The NG was made of a free cantilever beam that consisted of a five-layer structure: a flexible polymer substrate, ZnO nanowire textured films on its top and bottom surfaces, and electrodes on the surfaces. When it was strained to 0.12% at a strain rate of 3.56% S(-1), the measured output voltage reached 10 V, and the output current exceeded 0.6 μA (corresponding power density 10 mW/cm(3)). A system was built up by integrating a NG, rectification circuit, capacitor for energy storage, sensor, and RF data transmitter. Wireless signals sent out by the system were detected by a commercial radio at a distance of 5-10 m. This study proves the feasibility of using ZnO nanowire NGs for building self-powered systems, and its potential application in wireless biosensing, environmental/infrastructure monitoring, sensor networks, personal electronics, and even national security.

  6. Artificial intelligence in the service of system administrators

    Science.gov (United States)

    Haen, C.; Barra, V.; Bonaccorsi, E.; Neufeld, N.

    2012-12-01

    The LHCb online system relies on a large and heterogeneous IT infrastructure made from thousands of servers on which many different applications are running. They run a great variety of tasks: critical ones such as data taking and secondary ones like web servers. The administration of such a system and making sure it is working properly represents a very important workload for the small expert-operator team. Research has been performed to try to automatize (some) system administration tasks, starting in 2001 when IBM defined the so-called “self objectives” supposed to lead to “autonomic computing”. In this context, we present a framework that makes use of artificial intelligence and machine learning to monitor and diagnose at a low level and in a non intrusive way Linux-based systems and their interaction with software. Moreover, the multi agent approach we use, coupled with an “object oriented paradigm” architecture should increase our learning speed a lot and highlight relations between problems.

  7. Federal Emergency Management Information System (FEMIS) system administration guide. Version 1.2

    Energy Technology Data Exchange (ETDEWEB)

    Burford, M.J.; Burnett, R.A.; Curtis, L.M. [and others

    1996-05-01

    The Federal Emergency Management Information System (FEMIS) is an emergency management planning and analysis tool that is being developed under the direction of the US Army Chemical biological Defense Command. The FEMIS System Administration Guide defines FEMIS hardware and software requirements and gives instructions for installing the FEMIS system package. System administrators, database administrators, and general users can use this guide to install, configure, and maintain the FEMIS client software package. This document provides a description of the FEMIS environment; distribution media; data, communications, and electronic mail servers; user workstations; and system management.

  8. Operations system administration plan for HANDI 2000 business management system

    Energy Technology Data Exchange (ETDEWEB)

    Adams, D.E.

    1998-09-29

    The Hanford Data Integration 2000 (HANDI 2000) Project will result in an integrated and comprehensive set of functional applications containing core information necessary to support the Project Hanford Management Contract (PHMC). It is based on the Commercial-Off-The-Shelf (COTS) product solution with commercially proven business processes. This includes systems that support finance, supply, chemical management, human resources and payroll activities on the Hanford Site. The Passport (PP) software is an integrated application for Accounts Payable, Contract Management, Inventory Management, Purchasing, and Material Safety Data Sheets (MSDS). The PeopleSoft (PS) software is an integrated application for General Ledger, Project Costing, Human Resources, Payroll, Benefits, and Training. The implementation of this set of products, as the first deliverable of the HANDI 2000 Project, is referred to as Business Management System (BMS) and MSDS.

  9. Asymmetric operation of AC power transmission systems : the key to optimizing power system reliability and economics

    Energy Technology Data Exchange (ETDEWEB)

    Marceau, R.J. [University of Ontario Inst. of Technology, Oshawa, ON (Canada); McGillis, D.T. [McGill Univ., Montreal, PQ (Canada). Dept. of Electrical and Computer Engineering]|[Concordia Univ., Montreal, PQ (Canada). Dept. of Electrical and Computer Engineering; Sana, A.R.

    2006-07-01

    This book provides an invaluable tool for professionals working in the field of electrical engineering and applied science. It presents a simple and cost-effective strategy to operate alternating current (AC) power transmission systems more reliably and economically. Typically, bulk power transmission systems are operated symmetrically. When a problem such as a short-circuit occurs on a 3-phase line on an individual phase, all 3 phases are taken out of service. Such a strategy is fundamentally inefficient, given that most faults are single-line-to-ground faults. The more effective operating strategy presented in this book is based on the concept of asymmetric operation, which defines the operation of a 3-phase AC transmission line as 3 independently operated entities. As such, a 3-phase line can be operated with 1 or 2 phases out of service for single-line transmission corridors or with 1 , 2 or 3 phases out of service in the case of multiple-line corridors. This approach also maintains 3-phase symmetrical operation at its extremities, thereby protecting loads and power plants from undesirable voltages and currents. The overall integrity of 3-phase transmission is maintained in terms of power delivery, balanced voltages and currents even in the event of failures in part of the transmission system. The result is improved security. 67 refs., 42 tabs., 73 figs., 2 appendices.

  10. Model documentation: Natural Gas Transmission and Distribution Model of the National Energy Modeling System; Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-02-24

    The Natural Gas Transmission and Distribution Model (NGTDM) is a component of the National Energy Modeling System (NEMS) used to represent the domestic natural gas transmission and distribution system. NEMS is the third in a series of computer-based, midterm energy modeling systems used since 1974 by the Energy Information Administration (EIA) and its predecessor, the Federal Energy Administration, to analyze domestic energy-economy markets and develop projections. This report documents the archived version of NGTDM that was used to produce the natural gas forecasts used in support of the Annual Energy Outlook 1994, DOE/EIA-0383(94). The purpose of this report is to provide a reference document for model analysts, users, and the public that defines the objectives of the model, describes its basic design, provides detail on the methodology employed, and describes the model inputs, outputs, and key assumptions. It is intended to fulfill the legal obligation of the EIA to provide adequate documentation in support of its models (Public Law 94-385, Section 57.b.2). This report represents Volume 1 of a two-volume set. (Volume 2 will report on model performance, detailing convergence criteria and properties, results of sensitivity testing, comparison of model outputs with the literature and/or other model results, and major unresolved issues.) Subsequent chapters of this report provide: (1) an overview of the NGTDM (Chapter 2); (2) a description of the interface between the National Energy Modeling System (NEMS) and the NGTDM (Chapter 3); (3) an overview of the solution methodology of the NGTDM (Chapter 4); (4) the solution methodology for the Annual Flow Module (Chapter 5); (5) the solution methodology for the Distributor Tariff Module (Chapter 6); (6) the solution methodology for the Capacity Expansion Module (Chapter 7); (7) the solution methodology for the Pipeline Tariff Module (Chapter 8); and (8) a description of model assumptions, inputs, and outputs (Chapter 9).

  11. Information system for administrating and distributing color images through internet

    Directory of Open Access Journals (Sweden)

    2007-01-01

    Full Text Available The information system for administrating and distributing color images through the Internet ensures the consistent replication of color images, their storage - in an on-line data base - and predictable distribution, by means of a digitally distributed flow, based on Windows platform and POD (Print On Demand technology. The consistent replication of color images inde-pendently from the parameters of the processing equipment and from the features of the programs composing the technological flow, is ensured by the standard color management sys-tem defined by ICC (International Color Consortium, which is integrated by the Windows operation system and by the POD technology. The latter minimize the noticeable differences between the colors captured, displayed or printed by various replication equipments and/or edited by various graphical applications. The system integrated web application ensures the uploading of the color images in an on-line database and their administration and distribution among the users via the Internet. For the preservation of the data expressed by the color im-ages during their transfer along a digitally distributed flow, the software application includes an original tool ensuring the accurate replication of colors on computer displays or when printing them by means of various color printers or presses. For development and use, this application employs a hardware platform based on PC support and a competitive software platform, based on: the Windows operation system, the .NET. Development medium and the C# programming language. This information system is beneficial for creators and users of color images, the success of the printed or on-line (Internet publications depending on the sizeable, predictable and accurate replication of colors employed for the visual expression of information in every activity fields of the modern society. The herein introduced information system enables all interested persons to access the

  12. The Diagnostic System of A – 604 Automatic Transmission

    Directory of Open Access Journals (Sweden)

    Czaban Jaroslaw

    2014-09-01

    Full Text Available Automatic gearbox gains increasing popularity in Europe. Little interest in diagnosis of such type of transmission in Poland results from the fact of small share in the whole market of operated cars, so there is a lack of availability of special diagnostic devices. These factors cause issues of expensive repairs, often involving a replacement of subassembly to new or aftermarket one. To a small extent some prophylactic diagnostic tests are conducted, which can eliminate future gearbox system failures. In the paper, the proposition of diagnostic system of popular A - 604 gearbox was presented. The authors are seeking for the possibility of using such type of devices to functional elaboration of gearboxes after renovation. The built system pursues the drive of the researched object, connected with simulated load, where special controller, replacing the original one, is responsible for controlling gearbox operation. This way is used to evaluate the mechanic and hydraulic parts' state. Analysis of signal runs, registered during measurements lets conclude about operation correctness, where as comparison with stock data verifies the technical state of an automatic gearbox.

  13. Public sector administration of ecological economics systems using mediated modeling.

    Science.gov (United States)

    van den Belt, Marjan; Kenyan, Jennifer R; Krueger, Elizabeth; Maynard, Alison; Roy, Matthew Galen; Raphael, Ian

    2010-01-01

    In today's climate of government outsourcing and multiple stakeholder involvement in public sector management and service delivery, it is more important than ever to rethink and redesign the structure of how policy decisions are made, implemented, monitored, and adapted to new realities. The traditional command-and-control approach is now less effective because an increasing amount of responsibility to deliver public goods and services falls on networks of nongovernment agencies. Even though public administrators are seeking new decision-making models in an increasingly more complex environment, the public sector currently only sparsely utilizes Mediated Modeling (MM). There is growing evidence, however, that by employing MM and similar tools, public interest networks can be better equipped to deal with their long-term viability while maintaining the short-term needs of their clients. However, it may require a shift in organizational culture within and between organizations to achieve the desired results. This paper explores the successes and barriers to implementing MM and similar tools in the public sector and offers insights into utilizing them through a review of case studies and interdisciplinary literature. We aim to raise a broader interest in MM and similar tools among public sector administrators at various administrative levels. We focus primarily, but not exclusively, on those cases operating at the interface of ecology and socio-economic systems.

  14. Transmissibility of the monkeypox virus clades via respiratory transmission: investigation using the prairie dog-monkeypox virus challenge system.

    Directory of Open Access Journals (Sweden)

    Christina L Hutson

    Full Text Available Monkeypox virus (MPXV is endemic within Africa where it sporadically is reported to cause outbreaks of human disease. In 2003, an outbreak of human MPXV occurred in the US after the importation of infected African rodents. Since the eradication of smallpox (caused by an orthopoxvirus (OPXV related to MPXV and cessation of routine smallpox vaccination (with the live OPXV vaccinia, there is an increasing population of people susceptible to OPXV diseases. Previous studies have shown that the prairie dog MPXV model is a functional animal model for the study of systemic human OPXV illness. Studies with this model have demonstrated that infected animals are able to transmit the virus to naive animals through multiple routes of exposure causing subsequent infection, but were not able to prove that infected animals could transmit the virus exclusively via the respiratory route. Herein we used the model system to evaluate the hypothesis that the Congo Basin clade of MPXV is more easily transmitted, via respiratory route, than the West African clade. Using a small number of test animals, we show that transmission of viruses from each of the MPXV clade was minimal via respiratory transmission. However, transmissibility of the Congo Basin clade was slightly greater than West African MXPV clade (16.7% and 0% respectively. Based on these findings, respiratory transmission appears to be less efficient than those of previous studies assessing contact as a mechanism of transmission within the prairie dog MPXV animal model.

  15. 75 FR 64389 - Proposed Recommendation to the Social Security Administration for Occupational Information System...

    Science.gov (United States)

    2010-10-19

    ... ADMINISTRATION Proposed Recommendation to the Social Security Administration for Occupational Information System... on plans and activities to create an occupational information system tailored specifically for our... System Development Planning. The comment period is open through November 8, 2010. Contact...

  16. Response prediction techniques and case studies of a path blocking system based on Global Transmissibility Direct Transmissibility method

    Science.gov (United States)

    Wang, Zengwei; Zhu, Ping; Zhao, Jianxuan

    2017-02-01

    In this paper, the prediction capabilities of the Global Transmissibility Direct Transmissibility (GTDT) method are further developed. Two path blocking techniques solely using the easily measured variables of the original system to predict the response of a path blocking system are generalized to finite element models of continuous systems. The proposed techniques are derived theoretically in a general form for the scenarios of setting the response of a subsystem to zero and of removing the link between two directly connected subsystems. The objective of this paper is to verify the reliability of the proposed techniques by finite element simulations. Two typical cases, the structural vibration transmission case and the structure-borne sound case, in two different configurations are employed to illustrate the validity of proposed techniques. The points of attention for each case have been discussed, and conclusions are given. It is shown that for the two cases of blocking a subsystem the proposed techniques are able to predict the new response using measured variables of the original system, even though operational forces are unknown. For the structural vibration transmission case of removing a connector between two components, the proposed techniques are available only when the rotational component responses of the connector are very small. The proposed techniques offer relative path measures and provide an alternative way to deal with NVH problems. The work in this paper provides guidance and reference for the engineering application of the GTDT prediction techniques.

  17. Statistics and Analysis on Reliability of HVDC Transmission Systems of SGCC

    Institute of Scientific and Technical Information of China (English)

    Xu

    2010-01-01

    Reliability level of HVDC power transmission systems becomes an important factor impacting the entire power grid. The author analyzes the reliability of HVDC power transmission systems owned by SGCC since 2003 in respect of forced outage times, forced energy unavailability, scheduled energy unavailability and energy utilization efficiency. The results show that the reliability level of HVDC power transmission systems owned by SGCC is improving. By analyzing different reliability indices of HVDC power transmission system, the maximum asset benefits of power grid can be achieved through building a scientific and reasonable reliability evaluation system.

  18. Study on New Concatenated Code in WDM Optical Transmission Systems

    Institute of Scientific and Technical Information of China (English)

    YUAN Jian-guo; JIANG Ze; MAO You-ju; YE Wen-wei

    2007-01-01

    A new concatenated code of RS(255,239)+BCH(2 040,1 930) code to be suitable for WDM optical transmission systems is proposed.The simulation results show that this new concatenated code,compared with the RS(255,239)+CSOC(k0/n0=6/7,J=8) code in ITU-T G.75.1,has a lower redundancy and better error-correction performance,furthermore,its net coding gain(NCG) is respectively 0.46 dB,0.43 dB more than that of RS(255,239)+CSOC(k0/n0 =6/7,J=8) code and BCH(3 860,3 824)+BCH(2 040,1 930) code in ITU-T G.75.1 at the third iteration for the bit error rate(BER) of 10-12.Therefore,the new super forward error correction(Super-FEC) concatenated code can be better used in ultra long-haul,ultra large-capacity and ultra high-speed WDM optical communication systems.

  19. Unified active and reactive power modulation of HVDC transmission systems

    Science.gov (United States)

    Grund, C. E.; Pohl, R. V.

    1981-11-01

    The power modulation of a high voltage direct current (HVDC) system for stabilization of an ac/dc network was investigated. It was found that simultaneous modulation of both dc current and voltage was more effective than just current modulation by itself, since the dc voltage modulation could be used to minimize the reactive power changes resulting from a change of the dc current. This helps stabilize the ac busbar voltages at the converters, which reduces undesirable load flow changes to voltage dependent ac loads, thus improving the effectiveness of the dc power modulation. This unified modulation control concept was evaluated by means of digital computer studies as well as a special purpose HVDC simulator. Several combined ac/dc power transmission systems were synthesized for testing of different modulation controller concepts. An optimum controller design incorporating a linear quadratic control algorithm with full state feedback was first studied. This provided a basis for comparison of suboptimal controller designs utilizing reduced state feedback and a Kalman filter state reconstruction technique.

  20. 47 CFR 73.644 - Subscription TV transmission systems.

    Science.gov (United States)

    2010-10-01

    ... adjacent channel stations must not increase over that resulting from the transmission of programming with..., of Subpart H of Part 15 of the FCC Rules for TV Interface Devices. (c) Prior to commencing the transmission of encoded subscription programming, the licensee or permittee of a TV broadcast or low power...

  1. Western Area Power Administration. Combined power system financial statements

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-02-26

    This report presents the results of the independent certified public accountants` audit of the Western Area Power Administration`s combined power system statements of assets, Federal investment and liabilities, and the related combined statements of revenues, expenses and accumulated net revenues, and cash flows. The auditors` report on Westerns internal control structure disclosed three new reportable conditions concerning the lack of: (1) a reconciliation of stores inventory from subsidiary ledgers to summary financial information, (2) communication of interest during construction and related adjustments to interest on Federal investment, and (3) a system to prevent and detect power billing errors. None of the conditions were considered to be material weaknesses. Western provided concurrence and corrective action plans. The auditors` report on Western`s compliance with laws and regulations also disclosed two new instances of noncompliance. Western failed to calculate nonreimbursable expenses in accordance with the Grand Canyon Protection Act and had an unexplained difference in gross Federal investment balances used to calculate interest on Federal investment. Western provided concurrence and corrective action plans for the instances.

  2. Power Improvement of Transmission Line Using High Voltage Direct Current (Hvdc Transmission System

    Directory of Open Access Journals (Sweden)

    Lasisi, H

    2016-08-01

    Full Text Available The use of long EHV (Extremely High Voltage ac lines for the transmission of electrical energy increases the line reactance and susceptance which limits the thermal loadings on the line in order to keep sufficient margin against transient instability. With the scheme proposed in this paper, it is possible to load the lines very close to their limit with zero reactance and susceptance. The conductors are allowed to carry usual ac along with dc superimposed on it. The added dc power flow does not cause any transient instability. The scheme comprises a twelve-pulse bridge rectifier, dc-links, pulse width modulated (PSW-voltage sourced inverter (VSI and converter transformers. The master current controller is used to implement the scheme which senses ac current and regulates the dc current orders for converters online such that conductor current never exceeds its thermal limit. This paper gives the feasibility of converting a double circuit ac line into composite ac–dc power transmission line given the advantage of stability improvement, damping oscillations, voltage stabilization and reactive power compensation for ac weak buses. Simulation and experimental studies using MATLAB (Matrix Laboratory are carried out for the coordinated control as well as independent control of ac and dc power transmissions.

  3. Model documentation Natural Gas Transmission and Distribution Model of the National Energy Modeling System. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-02-26

    The Natural Gas Transmission and Distribution Model (NGTDM) of the National Energy Modeling System is developed and maintained by the Energy Information Administration (EIA), Office of Integrated Analysis and Forecasting. This report documents the archived version of the NGTDM that was used to produce the natural gas forecasts presented in the Annual Energy Outlook 1996, (DOE/EIA-0383(96)). The purpose of this report is to provide a reference document for model analysts, users, and the public that defines the objectives of the model, describes its basic approach, and provides detail on the methodology employed. Previously this report represented Volume I of a two-volume set. Volume II reported on model performance, detailing convergence criteria and properties, results of sensitivity testing, comparison of model outputs with the literature and/or other model results, and major unresolved issues.

  4. Voith power transmission systems in diesel multiple units and railcars. A review on recent developments

    Energy Technology Data Exchange (ETDEWEB)

    Paetzold, W. [Voith Turbo GmbH und Co. KG, Heidenheim (Germany). Rail Div.

    1999-04-01

    Voith today offers complete transmission systems consisting of hydrodynamic and hydromechanical transmissions with integrated retarders, cardan shafts, final drives and cooling units. For DMUs with underfloor powerpacks, the hydrodynamic power transmission system currently is the pre-eminent drive system worldwide and meets the established standards for rail service, i.e. high availability, low operating costs and a reasonable purchasing price. In this article, the author describes Voith`s contribution to the further development of these transmission systems in several modern dieselhydraulic railcars and DMUs for regional and main-line operations. (orig.)

  5. 75 FR 2457 - Defense Federal Acquisition Regulation Supplement; Business Systems-Definition and Administration...

    Science.gov (United States)

    2010-01-15

    ... define contractor business systems as accounting systems, estimating systems, purchasing systems, earned... conditions of this contract. Business systems means-- (1) Accounting system, if this contract includes the... Federal Acquisition Regulation Supplement; Business Systems--Definition and Administration (DFARS...

  6. A Hybrid LCC-VSC HVDC Transmission System Supplying a Passive Load

    Science.gov (United States)

    Kotb, Omar

    High Voltage Direct Current (HVDC) transmission systems continue to be an excellent asset in modern power systems, mainly for their ability to overcome the problems of AC transmission, such as the interconnection of asynchronous grids, stability of long transmission lines, and use of long cables for power transmission. In the past 20 years, Voltage Source Converter (VSC)-HVDC transmission systems were developed and installed in many projects, thereby adding more operational benefits to DC transmission option, such as high controllability, ability to supply weak networks, and reduced converter reactive power demand. Nevertheless, VSC-HVDC transmission suffers from the disadvantages of high losses and cost. In this research, a hybrid HVDC employing a Line Commutated Converter (LCC) as rectifier and a VSC as inverter is used to supply a passive network through a DC cable. The hybrid system is best suited for unidirectional power transmission scenarios, such as power transmission to islands and remote load centers, where the construction of new transmission lines is prohibitively expensive. Control modes for the rectifier and inverter are selected and implemented using Proportional Integral (PI) controllers. Special control schemes are developed for abnormal operating conditions such as starting at light load and recovering from AC network faults. The system performance under steady state and transient conditions is investigated by EMTP-RV simulations. The results show the feasibility of the hybrid system.

  7. ATLAS TDAQ System Administration: evolution and re-design

    CERN Document Server

    Ballestrero, Sergio; The ATLAS collaboration; Brasolin, Franco; Contescu, Alexandru Cristian; Dubrov, Sergei; Fazio, Daniel; Korol, Aleksandr; Lee, Christopher Jon; Scannicchio, Diana; Twomey, Matthew Shaun

    2015-01-01

    The ATLAS Trigger and Data Acquisition (TDAQ) system is responsible for the online processing of live data, streaming from the ATLAS experiment at the Large Hadron Collider (LHC) at CERN. The online farm is composed of $\\sim 3000$ servers, processing the data readout from $\\sim 100$ million detector channels through multiple trigger levels. During the two years of the first Long Shutdown (LS1) there has been a tremendous amount of work done by the ATLAS TDAQ System Administrators, implementing numerous new software applications, upgrading the OS and the hardware, changing some design philosophies and exploiting the High Level Trigger farm with different purposes. The OS version has been upgraded to SLC6; for the largest part of the farm, which is composed by net booted nodes, this required a completely new design of the net booting system. In parallel, the migration to Puppet of the Configuration Management systems has been completed for both net booted and local booted hosts; the Post-Boot Scripts system and...

  8. Polar On-Line Acquisition Relay and Transmission System (POLARATS)

    Energy Technology Data Exchange (ETDEWEB)

    Yuracko, K.

    2004-07-15

    POLARATS (Polar On-Line Acquisition Relay And Transmission System) is being developed by YAHSGS LLC (YAHSGS) and Oak Ridge National Laboratory (ORNL) to provide remote, unattended monitoring of environmental parameters under harsh environmental conditions. In particular, instrumental design and engineering is oriented towards protection of human health in the Arctic, and with the additional goal of advancing Arctic education and research. POLARATS will obtain and transmit environmental data from hardened monitoring devices deployed in locations important to understanding atmospheric and aquatic pollutant migration as it is biomagnified in Arctic food chains. An Internet- and personal computer (PC)-based educational module will provide real time sensor data, on-line educational content, and will be integrated with workbooks and textbooks for use in middle and high school science programs. The educational elements of POLARATS include an Internet-based educational module that will instruct students in the use of the data and how those data fit into changing Arctic environments and food chains. POLARATS will: (1) Enable students, members of the community, and scientific researchers to monitor local environmental conditions in real time over the Internet; and (2) Provide additional educational benefits through integration with middle- and high-school science curricula. Information will be relayed from POLARATS devices to classrooms and libraries along with custom-designed POLARATS teaching materials that will be integrated into existing curricula to enhance the educational benefits realized from the information obtained.

  9. Stress transmission through a model system of cohesionless elastic grains

    Science.gov (United States)

    Da Silva, Miguel; Rajchenbach, Jean

    2000-08-01

    Understanding the mechanical properties of granular materials is important for applications in civil and chemical engineering, geophysical sciences and the food industry, as well as for the control or prevention of avalanches and landslides. Unlike continuous media, granular materials lack cohesion, and cannot resist tensile stresses. Current descriptions of the mechanical properties of collections of cohesionless grains have relied either on elasto-plastic models classically used in civil engineering, or on a recent model involving hyperbolic equations. The former models suggest that collections of elastic grains submitted to a compressive load will behave elastically. Here we present the results of an experiment on a two-dimensional model system-made of discrete square cells submitted to a point load-in which the region in which the stress is confined is photoelastically visualized as a parabola. These results, which can be interpreted within a statistical framework, demonstrate that the collective response of the pile contradicts the standard elastic predictions and supports a diffusive description of stress transmission. We expect that these findings will be applicable to problems in soil mechanics, such as the behaviour of cohesionless soils or sand piles.

  10. Central amygdala opioid transmission is necessary for increased high-fat intake following 24-h food deprivation, but not following intra-accumbens opioid administration.

    Science.gov (United States)

    Parker, Kyle E; Johns, Howard W; Floros, Ted G; Will, Matthew J

    2014-03-01

    Previous research has demonstrated a dissociation of certain neural mediators that contribute to the increased consumption of a high-fat diet that follows intra-accumbens (Acb) administration of μ-opioid receptor agonists vs. 24-h food deprivation. These two models, both which induce rapid consumption of the diet, have been shown to involve a distributed corticolimbic circuitry, including the amygdala. Specifically, the central amygdala (CeA) has been shown to be involved in high-fat feeding within both opioid and food-deprivation driven models. The present experiments were conducted to examine the more specific role of CeA opioid transmission in mediating high-fat feeding driven by either intra-Acb administration of the μ-opioid agonist d-Ala2-NMe-Phe4-Glyol5-enkephalin (DAMGO) or 24-h home cage food deprivation. Injection of DAMGO into the Acb (0.25 μg/0.5 μl/side) increased consumption of the high-fat diet, but this feeding was unaffected by administration of opioid antagonist, naltrexone (5 μg/0.25 μl/side) administered into the CeA. In contrast, intra-CeA naltrexone administration attenuated high-fat intake driven by 24-h food deprivation, demonstrating a specific role for CeA opioid transmission in high-fat consumption. Intra-CeA naltrexone administration alone had no effect on baseline feeding levels within either feeding model. These findings suggest that CeA opioid transmission mediates consumption of a palatable high-fat diet driven by short-term negative-energy balance (24-h food deprivation), but not intra-Acb opioid receptor activation.

  11. A Study on System Availability Vs System Administration Efforts with Mathematical Models

    Institute of Scientific and Technical Information of China (English)

    郑建德

    2003-01-01

    Two mathematical models are developed in this paper to study the effectiveness of system administration efforts on the improvement of system availability, based on the assumption that there exists a transitional state for a computer system in operation before it is brought down by some hardware or software problems and with intensified system administration efforts, it is possible to discover and fix the problems in time to bring the system back to normal state before it is down. Markov chain is used to simulate the transition of system states. A conclusion is made that increasing system administration efforts may be a cost-effective way to meet the requirements for moderate improvement on system availability, but higher demand on this aspect still has to be met by advanced technologies.

  12. 47 CFR 73.6024 - Transmission standards and system requirements.

    Science.gov (United States)

    2010-10-01

    ... RADIO SERVICES RADIO BROADCAST SERVICES Class A Television Broadcast Stations § 73.6024 Transmission... cause any condition of uncorrectable interference due to radiation of radio frequency energy outside...

  13. Settlement Between Electric Transmission Companies under the Point of Connection Tariff or "Postal Stamp" System (Japanese)

    OpenAIRE

    Hatta, Tatsuo

    2009-01-01

    This paper discusses how an electric transmission company in a pass-through area should settle the cost of a pass-through with the neighboring transmission companies under the point-of-connection tariff system. First, the paper shows that if the cost of the pass-through is settled based on the principle that determines the (metered) power transmission fares for ordinary customers (i.e. injectors and withdrawers) of the transmission companies, the fare receipts of the pass-through transmission...

  14. Study for wireless power transmission of nuclear robot system

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jongseog [Central Research Institute of Korea Hydro and Nuclear Power Co., Daejeon (Korea, Republic of)

    2013-05-15

    Gasoline engine or electric motor is generally used for driving power of working. Gasoline tank is uncomfortable to carry. Battery capacity does not sustain long time working. Frequent moving back of robot to power charger or refueling tank is inconvenient. Long power cable connection occur winding problem if there are complex structures in walking way. We need some solution for continuous supply of robot energy at the free moving condition of robot. 'Wireless power transmission' is one of the solutions. Some experiment result to transmit wireless power to moving robot is described herein. To find possible wireless power transmission method for nuclear robot, wireless power transmission tests were performed. As result of these tests, it was confirmed that wireless power transmission by using dipole and mat type magnetic induction were possible. As result of flying robot experiment, it was realized that development of light weight core for receiver and wave reflection device for high directional transmitter are necessary for practical use of the dipole type wireless power transmission. Small size core and high directional transmitter will be next target. Mat type wireless power transmission is regarded as useful for robot power charging station in the inside containment.

  15. Academic Management and Administration System Reform in Higher Education Institutions

    Institute of Scientific and Technical Information of China (English)

    Xiang Xianming

    2006-01-01

    Reforms in colleges and universities should promote the humanistic character of higher education-rather than simply serve for pure economic production--but also observe the sacred mission of transmiting and creating culture and knowledge.wim these two possessing momentous differences.These then demand rationality in academic management to guard against declination toward dehumanization or bureaucracy.Thus.the relationship between academic power and administrative power must be harmonized,and a reasonable equilibrium must be guaranteed.An academic management idea of power in learning is particularly emphasized to overcome the false polarity of managerism,straightforwardly reducing complicated academic operations to a kind of economic prosecution,hence truly promoting the function of a higher education system.

  16. Simulation Study on Coil Design of Wireless Power Transfer System for Optimal Transmission Efficiency

    Directory of Open Access Journals (Sweden)

    Hao Qiang

    2013-05-01

    Full Text Available As an emerging research field, Wireless Power Transfer (WPT has attracted wide spread attention recently. In this study, the coil design of WPT system for optimal transmission efficiency is investigated. We deduce Tthe design criteria are deduced to meet various conditions of transmission distance and load. The results of simulation and experiment show the transmission efficiency from transmitting coil to receiving coil can keep high when the corresponding optimal condition is achieved. Thusen it can improve the overall transmission efficiency of the WPT system and it makes it suitable for the practical application of WPT system.

  17. Wavelet Based Fault Detection, Classification in Transmission System with TCSC Controllers

    Directory of Open Access Journals (Sweden)

    G.Satyanarayana,

    2015-08-01

    Full Text Available This paper presents simulation results of the application of distance relays for the protection of transmission systems employing flexible alternating current transmission controllers such as Thyristor Controlled Series Capacitor (TCSC. The complete digital simulation of TCSC within a transmission system is performed in the MATLAB/Simulink environment using the Power System Block set (PSB. This paper presents an efficient method based on wavelet transforms both fault detection and classification which is almost independent of fault impedance, fault location and fault inception angle of transmission line fault currents with FACTS controllers.

  18. 77 FR 11355 - Defense Federal Acquisition Regulation Supplement; Business Systems-Definition and Administration...

    Science.gov (United States)

    2012-02-24

    ... Defense Federal Acquisition Regulation Supplement; Business Systems--Definition and Administration (DFARS... proposed rule for Business Systems-- Definition and Administration (DFARS Case 2009-D038) in the Federal... contractor business systems, DoD has clarified the definition and administration of contractor...

  19. 75 FR 75549 - Defense Federal Acquisition Regulation Supplement; Business Systems-Definition and Administration...

    Science.gov (United States)

    2010-12-03

    ... Acquisition Regulation Supplement; Business Systems-- Definition and Administration (DFARS Case 2009-D038...D published a proposed rule for Business Systems--Definition and Administration (DFARS Case 2009... contractor business systems, DoD is considering a rule to clarify the definition and administration...

  20. Experimental characterization of dispersion maps with Raman gain in 160 Gb/s transmission systems

    DEFF Research Database (Denmark)

    Zhenbo, Xu; Seoane, Jorge; Siahlo, Andrei;

    2004-01-01

    We investigate the combined effects of dispersion compensation and Raman amplification in SMF-based transmission span of 160 Gb/s system. The post compensation map shows better power tolerance.......We investigate the combined effects of dispersion compensation and Raman amplification in SMF-based transmission span of 160 Gb/s system. The post compensation map shows better power tolerance....

  1. 47 CFR 74.795 - Digital low power TV and TV translator transmission system facilities.

    Science.gov (United States)

    2010-10-01

    ... translator transmission system facilities. (a) A digital low power TV or TV translator station shall operate... 47 Telecommunication 4 2010-10-01 2010-10-01 false Digital low power TV and TV translator transmission system facilities. 74.795 Section 74.795 Telecommunication FEDERAL COMMUNICATIONS...

  2. Performance analysis for optimum transmission and comparison with maximal ratio transmission for MIMO systems with cochannel interference

    Directory of Open Access Journals (Sweden)

    Lin Sheng-Chou

    2011-01-01

    Full Text Available Abstract This article presents the performance analysis of multiple-input/multiple-output (MIMO systems with quadrature amplitude modulation (QAM transmission in the presence of cochannel interference (CCI in nonfading and flat Rayleigh fading environments. The use of optimum transmission (OT and maximum ratio transmission (MRT is considered and compared. In addition to determining precise results for the performance of QAM in the presence of CCI, it is our another aim in this article to examine the validity of the Gaussian interference model in the MRT-based systems. Nyquist pulse shaping and the effects of cross-channel intersymbol interference produced by CCI due to random symbol of the interfering signals are considered in the precise interference model. The error probability for each fading channel is estimated fast and accurately using Gauss quadrature rules which can approximate the probability density function (pdf of the output residual interference. The results of this article indicate that Gaussian interference model may overestimate the effects of interference, particularly, for high-order MRT-based MIMO systems over fading channels. In addition, OT cannot always outperform MRT due to the significant noise enhancement when OT intends to cancel CCI, depending on the combination of the antennas at the transmitter and the receiver, number of interference and the statistical characteristics of the channel.

  3. Preliminary survey of integrated monitoring system for transmission liens. Sodensen sogo kanshi system no yobi kento

    Energy Technology Data Exchange (ETDEWEB)

    Sasano, Takao; Nishiyama, Fumihiko

    1988-04-01

    The integrated monitoring system of transmission lines utilizing ground wire with built-in optical fibres(OPGW) which was put to practical use was surveyed. The overhead transmission lines have potential to be impeded supply owing to the line exposure to severe natural envioronment or by the change of surrounding environment such as trees, buildings under lines and ground or by deterioration of equipments. This report describes the system to monitor integrally the transmission lines by using OPGW or sensor technology to maintain and operate with higher reliability and lower cost and to reflect in the design, except the conventional maintenance and checking. The effect to foresee and prevent accidents is expected from this system, but the regional difference must be considered. This system can provide continously reliable monitoring, collection of maintenance informations and operation support and further can provide accident informations to be used in the design through the evaluation. It is necessary to use highly reliable repeaters for optical informations, protect instruments under intense field, prevent malfunction and develop the auto-movable robot for taking picture and local weather prediction system in order to realize this system. (5 figs, 6 tabs, 8 refs)

  4. Parameter design and performance analysis of zero inertia continuously variable transmission system

    Institute of Scientific and Technical Information of China (English)

    胡建军; 吉毅; 晏玖江

    2015-01-01

    In order to solve the problem of weak power performance of vehicle equipped with continuously variable transmission (CVT) system working under transient operating conditions, a new CVT equipped with planetary gear mechanism and flywheel was researched, a design method of transmission parameter optimization was proposed, and the comprehensive matching control strategy was established for the new transmission system. Fuzzy controllers for throttle opening and CVT speed ratio were designed, and power performance and fuel economy of both vehicles respectively equipped with conventional CVT system and new transmission system wrere compared and analyzed by simulation. The results show that power performance and fuel economy of the vehicle equipped with new transmission system are better than that equipped with conventional CVT, thus the rationality of the parameter design method and control algorithm are verified.

  5. Design and Realization of Phased Array Radar Optical Fiber Transmission System

    Institute of Scientific and Technical Information of China (English)

    HU Shan-qing; LIU Feng; LONG Teng

    2007-01-01

    One optical fiber transmission system is designed.The modularization optical fiber transmission adapters were utilized in the system,so the system structure could be flexibly scalable.The sub-array adapter and signal processor adapter were designed and realized utilizing the new field programmable gate array (FPGA) which could drive the optical transceiver.The transmission agreement was designed based on the data stream.In order to solve the signal synchronization problem of the optical fiber transmitted phased array radar,a method named synchronous clock was designed.The fiber transmission error code rate of the system was zero with an experimental transmission velocity of 800 Mbit/s.The phased array radar system has detected the airplane target,thus validated the feasibility of the design method.

  6. PROXY-BASED PATCHING STREAM TRANSMISSION STRATEGY IN MOBILE STREAMING MEDIA SYSTEM

    Institute of Scientific and Technical Information of China (English)

    Liao Jianxin; Lei Zhengxiong; Ma Xutao; Zhu Xiaomin

    2006-01-01

    A mobile transmission strategy, PMPatching (Proxy-based Mobile Patching) transmission strategy is proposed, it applies to the proxy-based mobile streaming media system in Wideband Code Division Multiple Access (WCDMA) network. Performance of the whole system can be improved by using patching stream to transmit anterior part of the suffix that had been played back, and by batching all the demands for the suffix arrived in prefix period and patching stream transmission threshold period. Experimental results show that this strategy can efficiently reduce average network transmission cost and number of channels consumed in central streaming media server.

  7. The Communication System of the Presidential Administration in Romania

    Directory of Open Access Journals (Sweden)

    Flaviu Călin RUS

    2016-10-01

    Full Text Available The purpose of this article is to clarify the notions regarding the Presidential Administration in Romania. We shall try to emphasize the difference between the political communication and the public communication of the Presidential Administration. Along with the two objectives that have already been mentioned, we shall also attempt to make a presentation of the Communication Department of the Presidential Administration, as well as of the means through which the President expresses his/her ideas.

  8. Planning the future of JPL's management and administrative support systems around an integrated database

    Science.gov (United States)

    Ebersole, M. M.

    1983-01-01

    JPL's management and administrative support systems have been developed piece meal and without consistency in design approach over the past twenty years. These systems are now proving to be inadequate to support effective management of tasks and administration of the Laboratory. New approaches are needed. Modern database management technology has the potential for providing the foundation for more effective administrative tools for JPL managers and administrators. Plans for upgrading JPL's management and administrative systems over a six year period evolving around the development of an integrated management and administrative data base are discussed.

  9. Virtual Pipeline System Testbed to Optimize the U.S. Natural Gas Transmission Pipeline System

    Energy Technology Data Exchange (ETDEWEB)

    Kirby S. Chapman; Prakash Krishniswami; Virg Wallentine; Mohammed Abbaspour; Revathi Ranganathan; Ravi Addanki; Jeet Sengupta; Liubo Chen

    2005-06-01

    The goal of this project is to develop a Virtual Pipeline System Testbed (VPST) for natural gas transmission. This study uses a fully implicit finite difference method to analyze transient, nonisothermal compressible gas flow through a gas pipeline system. The inertia term of the momentum equation is included in the analysis. The testbed simulate compressor stations, the pipe that connects these compressor stations, the supply sources, and the end-user demand markets. The compressor station is described by identifying the make, model, and number of engines, gas turbines, and compressors. System operators and engineers can analyze the impact of system changes on the dynamic deliverability of gas and on the environment.

  10. Non-systemic transmission of tick-borne diseases: A network approach

    Science.gov (United States)

    Ferreri, Luca; Bajardi, Paolo; Giacobini, Mario

    2016-10-01

    Tick-borne diseases can be transmitted via non-systemic (NS) transmission. This occurs when tick gets the infection by co-feeding with infected ticks on the same host resulting in a direct pathogen transmission between the vectors, without infecting the host. This transmission is peculiar, as it does not require any systemic infection of the host. The NS transmission is the main efficient transmission for the persistence of the tick-borne encephalitis virus in nature. By describing the heterogeneous ticks aggregation on hosts through a bipartite graphs representation, we are able to mathematically define the NS transmission and to depict the epidemiological conditions for the pathogen persistence. Despite the fact that the underlying network is largely fragmented, analytical and computational results show that the larger is the variability of the aggregation, and the easier is for the pathogen to persist in the population.

  11. 75 FR 76692 - Defense Federal Acquisition Regulation Supplement; Business Systems-Definition and Administration...

    Science.gov (United States)

    2010-12-09

    ... Federal Acquisition Regulation Supplement; Business Systems--Definition and Administration (DFARS Case... INFORMATION: I. Background DoD published a proposed rule for Business Systems--Definition and...

  12. Initial assessment: electromagnetic compatibility aspects of proposed SPS Microwave Power Transmission System (MPTS) operations

    Energy Technology Data Exchange (ETDEWEB)

    1978-02-01

    An analysis of major concerns with regard to the effects on radio and electronic systems by the proposed Microwave Power Transmission System for transmitting power from a satellite solar power station to earth is presented. (LCL)

  13. Condition Assessment Technologies for Water Transmission and Distribution Systems

    Science.gov (United States)

    As part of the U.S. Environmental Protection Agency’s (EPA’s) Aging Water Infrastructure Research Program, this research was conducted to identify and characterize the state of the technology for structural condition assessment of drinking water transmission and distribution syst...

  14. Condition Assessment of Drinking Water Transmission and Distribution Systems

    Science.gov (United States)

    Condition assessment of water transmission and distribution mains is the collection of data and information through direct and/or indirect methods, followed by analysis of the data and information, to make a determination of the current and/or future structural, water quality, an...

  15. 47 CFR 73.875 - Modification of transmission systems.

    Science.gov (United States)

    2010-10-01

    ... RADIO BROADCAST SERVICES Low Power FM Broadcast Stations (LPFM) § 73.875 Modification of transmission... application on FCC Form 318. (1) Any construction of a new tower structure for broadcast purposes, except for replacement of an existing tower with a new tower of identical height and geographic coordinates. (2)...

  16. Analysis of transmission efficiency of the superconducting resonance coil according the materials of cooling system

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yu Kyeong; Hwang, Jun Won; Choi, Hyo Sang [Chosun University, Gwangju (Korea, Republic of)

    2016-03-15

    The wireless power transfer (WPT) system using a magnetic resonance was based on magnetic resonance coupling of the transmission and the receiver coils. In these system, it is important to maintain a high quality-factor (Q-factor) to increase the transmission efficiency of WPT system. Our research team used a superconducting coil to increase the Q-factor of the magnetic resonance coil in WPT system. When the superconductor is applied in these system, we confirmed that transmission efficiency of WPT system was higher than normal conductor coil through a preceding study. The efficiency of the transmission and the receiver coil is affected by the magnetic shielding effect of materials around the coils. The magnetic shielding effect is dependent on the type, thickness, frequency, distance, shape of materials. Therefore, it is necessary to study the WPT system on the basis of these conditions. In this paper, the magnetic shield properties of the cooling system were analyzed using the High-Frequency Structure Simulation (HFSS, Ansys) program. We have used the shielding materials such as plastic, aluminum and iron, etc. As a result, when we applied the fiber reinforced polymer (FRP), the transmission efficiency of WPT was not affected because electromagnetic waves went through the FRP. On the other hand, in case of a iron and aluminum, transmission efficiency was decreased because of their electromagnetic shielding effect. Based on these results, the research to improve the transmission efficiency and reliability of WPT system is continuously necessary.

  17. Seismic Performance Research of Transmission Tower in Consideration of the Pile-soil-structure System

    Science.gov (United States)

    Liu, Chuncheng; Mao, Long; Wang, Chongyang; Zha, Chuanming

    2016-11-01

    The seismic performance of transmission tower in consideration of pile-soil- structure dynamic interaction is researched through numerical simulation. Based on a transmission tower of a specific project, pile-soil-transmission tower coupled system is established. By using the method of time history, the pile-soil- transmission tower system dynamic response under seismic load were calculated, and comparing with the results without considering interaction system. Results show that, after considering interaction of the system, the period of the structure have extended and the mode of the structure lagged. On soft sites, compare with no considering the interaction, the results have a big difference, the relative increment of the maximum displacement at the top of the tower is 39.82%, respectively. Therefore it is suggested that the pile-soil-structure dynamic interaction should be fully considered in aseismic design of transmission tower on soft sites and medium soft sites.

  18. FORMING MANAGEMENT IMPACTS IN AVIATION COMPANIES ECONOMIC DEVELOPMENT ADMINISTRATION SYSTEM

    Directory of Open Access Journals (Sweden)

    Victoria Prokhorova

    2016-06-01

    Full Text Available Purpose: Oriented reflective approach to management involves restructuring of goal, ideal and pragmatic, creating a program of action, organizing, correcting, control the definition of the new strategy. This process is only possible with multidimensional analysis and reflection of all the administrative restructuring process and its elements in determining and planning activities, creating conditions of restructuring, predicting outcomes and consequences of making a choice of ways to solve problems means to achieve the goal of information called ' bonds with participants restructuring process and correction flow management process based on continuous reflection. Methods: Development of the system of economic development now requires the use of mechanisms for continuous monitoring of internal and external environment to identify factors that threaten businesses. Rest of this is possible through the use of diagnostic tests: static analysis, expert diagnosis, linear and dynamic programming. Results: Built as part of the study economic and mathematical models can determine the status and level of economic development potential of aerospace companies that were investigated, confirming the need for action to manage economic development. To develop the mechanism of competition in the aircraft building sector must: implementation in practice of management motivation mechanisms to ensure the appropriate level of interest in the functioning of airlines on the basis of private property; formation of economic market institutions in the field of aircraft construction, affecting the creation of a competitive environment. Discussion: Stipulates that in difficult economic crisis positive results can be achieved managers who are constantly looking for original approaches to inclusion in the development process by aligning internal external opportunities generated by market. It is concluded that aviation business management in times of economic instability or

  19. The emergence of global administrative systems: the case of sport.

    Directory of Open Access Journals (Sweden)

    L. Casini

    2015-04-01

    Full Text Available The “global” dimension of sport is, in the first instance, regulatory, and it embraces the whole complex of norms produced and implemented by regulatory sporting regimes at the international and domestic levels. These rules include not only private norms set by the International Olympic Committee (IOC and by International Federations (IFs but also “hybrid” public-private norms approved by the World Anti-Doping Agency (WADA and international law (such as the UNESCO Convention Against Doping in Sport. Sports law, therefore, is highly heterogeneous, and, above all, it is not simply transnational, but actually “global”. This law represents an autonomous global legal system, which displays distinctive features such as the presence of some separation of powers (in particular quasi-judicial, with the strategic role played by the Court of Arbitration for Sport and the development of relevant procedural principles (e.g. fairness and due process; and these principles operate both in rulemaking procedures (e.g. the adoption of the WADA Code and in adjudicatory ones (e.g. for disciplinary measures. Finally, this global legal system is made up with several international regulatory regimes, both private – such as the Olympic movement – and hybrid public and private – such as the world anti-doping regime. The paper will deal in particular with this latter issue. The analysis will focus on the global administrative dimensions of sports regimes, together with their inter-institutional relationships and its legal implications for the public and private interaction.

  20. Transmission needs across a fully renewable European power system

    CERN Document Server

    Rodriguez, Rolando A; Andresen, Gorm B; Heide, Dominik; Greiner, Martin

    2013-01-01

    The residual load and excess power generation of 27 European countries with a 100% penetration of variable renewable energy sources are explored in order to quantify the benefit of power transmission between countries. Estimates are based on extensive weather data, which allows for modelling of hourly mismatches between the demand and renewable generation from wind and solar photovoltaics. For separated countries, balancing is required to cover around 24% of the total annual energy consumption. This number can be reduced down to 15% once all countries are networked together with uncon- strained interconnectors. The reduction represents the maximum possible benefit of transmission for the countries. The total Net Transfer Capacity of the unconstrained interconnectors is roughly twelve times larger than current values. However, constrained interconnector capacities six times larger than the current values are found to provide 97% of the maximum possible benefit of cooperation. This motivates a detailed investig...

  1. Optical signal monitoring in phase modulated optical fiber transmission systems

    Science.gov (United States)

    Zhao, Jian

    Optical performance monitoring (OPM) is one of the essential functions for future high speed optical networks. Among the parameters to be monitored, chromatic dispersion (CD) is especially important since it has a significant impact on overall system performance. In this thesis effective CD monitoring approaches for phase-shift keying (PSK) based optical transmission systems are investigated. A number of monitoring schemes based on radio frequency (RF) spectrum analysis and delay-tap sampling are proposed and their performance evaluated. A method for dispersion monitoring of differential phase-shift keying (DPSK) signals based on RF power detection is studied. The RF power spectrum is found to increase with the increase of CD and decrease with polarization mode dispersion (PMD). The spectral power density dependence on CD is studied theoretically and then verified through simulations and experiments. The monitoring sensitivity for nonreturn-to-zero differential phase-shift keying (NRZ-DPSK) and return-to-zero differential phase-shift keying (RZ-DPSK) based systems can reach 80ps/nm/dB and 34ps/nm/dB respectively. The scheme enables the monitoring of differential group delay (DGD) and CD simultaneously. The monitoring sensitivity of CD and DGD can reach 56.7ps/nm/dB and 3.1ps/dB using a bandpass filter. The effects of optical signal-to-noise ratio (OSNR), DGD, fiber nonlinearity and chirp on the monitoring results are investigated. Two RF pilot tones are employed for CD monitoring of DPSK signals. Specially selected pilot tone frequencies enable good monitoring sensitivity with minimum influence on the received signals. The dynamic range exceeding 35dB and monitoring sensitivity up to 9.5ps/nm/dB are achieved. Asynchronous sampling technique is employed for CD monitoring. A signed CD monitoring method for 10Gb/s NRZ-DPSK and RZ-DPSK systems using asynchronous delay-tap sampling technique is studied. The demodulated signals suffer asymmetric waveform distortion if

  2. Dynamic Efficiency of a Container Crane’s Hoisting Transmission System under Hoisting Dynamic Load

    Directory of Open Access Journals (Sweden)

    Yuanyuan Liu

    2016-01-01

    Full Text Available The dynamic efficiency of hoisting transmission system on a container crane is fundamental for accurate efficiency prediction, while the dynamic efficiency of hoisting transmission system has not been investigated sufficiently. This paper will focus on dynamic efficiency of hoisting transmission system under hoisting dynamic load. A power loss model of gearbox was built. Then the dynamic model of gear transmission was developed including time-varying mesh stiffness and hoisting dynamic load was studied. Power loss, dynamic efficiency, and equivalent static efficiency were conducted in hoisting and lowering working conditions. The result shows that dynamic efficiency which consists of the significant lower frequency component coincided with hoisting load torque of the higher frequency component which is directly related to dynamic mesh and bearing force. And in two processes, the equivalent static efficiency in constant speed stage is min, whereas maximum value occurs in different stage. The research results lay a foundation for hoisting gear transmission dynamic efficiency analysis.

  3. Linearization Technologies for Broadband Radio-Over-Fiber Transmission Systems

    Directory of Open Access Journals (Sweden)

    Xiupu Zhang

    2014-11-01

    Full Text Available Linearization technologies that can be used for linearizing RoF transmission are reviewed. Three main linearization methods, i.e. electrical analog linearization, optical linearization, and electrical digital linearization are presented and compared. Analog linearization can be achieved using analog predistortion circuits, and can be used for suppression of odd order nonlinear distortion components, such as third and fifth order. Optical linearization includes mixed-polarization, dual-wavelength, optical channelization and the others, implemented in optical domain, to suppress both even and odd order nonlinear distortion components, such as second and third order. Digital predistortion has been a widely used linearization method for RF power amplifiers. However, digital linearization that requires analog to digital converter is severely limited to hundreds of MHz bandwidth. Instead, analog and optical linearization provide broadband linearization with up to tens of GHz. Therefore, for broadband radio over fiber transmission that can be used for future broadband cloud radio access networks, analog and optical linearization are more appropriate than digital linearization. Generally speaking, both analog and optical linearization are able to improve spur-free dynamic range greater than 10 dB over tens of GHz. In order for current digital linearization to be used for broadband radio over fiber transmission, the reduced linearization complexity and increased linearization bandwidth are required. Moreover, some digital linearization methods in which the complexity can be reduced, such as Hammerstein type, may be more promising and require further investigation.

  4. The integration of renewable energy sources into electric power transmission systems

    Energy Technology Data Exchange (ETDEWEB)

    Barnes, P.R.; Dykas, W.P.; Kirby, B.J.; Purucker, S.L. [Oak Ridge National Lab., TN (United States); Lawler, J.S. [Univ. of Tennessee, Knoxville, TN (United States)

    1995-07-01

    Renewable energy technologies such as photovoltaics, solar thermal power plants, and wind turbines are nonconventional, environmentally attractive sources of energy that can be considered for electric power generation. Many of the areas with abundant renewable energy resources (very sunny or windy areas) are far removed from major load centers. Although electrical power can be transmitted over long distances of many hundreds of miles through high-voltage transmission lines, power transmission systems often operate near their limits with little excess capacity for new generation sources. This study assesses the available capacity of transmission systems in designated abundant renewable energy resource regions and identifies the requirements for high-capacity plant integration in selected cases. In general, about 50 MW of power from renewable sources can be integrated into existing transmission systems to supply local loads without transmission upgrades beyond the construction of a substation to connect to the grid. Except in the Southwest, significant investment to strengthen transmission systems will be required to support the development of high-capacity renewable sources of 1000 MW or greater in areas remote from major load centers. Cost estimates for new transmission facilities to integrate and dispatch some of these high-capacity renewable sources ranged from several million dollars to approximately one billion dollars, with the latter figure an increase in total investment of 35%, assuming that the renewable source is the only user of the transmission facility.

  5. State of the art analysis of online fault location on AC cables in underground transmission systems

    DEFF Research Database (Denmark)

    Jensen, Christian Flytkjær; Gudmundsdottir, Unnur Stella; Bak, Claus Leth

    2011-01-01

    In this article the state of the art research for online fault location on cross-bonded transmission level cables is presented. The article is focused on the difficulties in using the algorithms developed for OHL-systems and distribution cables directly on cross-bonded transmission cables...

  6. Communication protocol in chassis detecting wireless transmission system based on WiFi

    Science.gov (United States)

    In chassis detecting wireless transmission system, the wireless network communication protocol plays a key role in the information exchange and synchronization between the host and chassis PDA. This paper presents a wireless network transmission protocol based on TCP/IP which makes the rules of info...

  7. Avoidance of Pressure Oscillations in Discrete Fluid Power Systems with Transmission Lines - An Analytical Approach

    DEFF Research Database (Denmark)

    Hansen, Anders Hedegaard; Pedersen, Henrik C.

    2014-01-01

    transmission lines often impose pressure oscillation/ pressure waves to occur in systems operated discrete or very fast. The current work focus on developing an analytical algorithm computing the flow requirement into a cylinder chamber through a transmission line that will impose a smooth pressure change...

  8. Joint impact of quantization and clipping on single- and multi-carrier block transmission systems

    NARCIS (Netherlands)

    Yang, H.; Schenk, T.C.W.; Smulders, P.F.M.; Fledderus, E.R.

    2008-01-01

    This work investigates the joint impact of quantization and clipping, caused by analog-to-digital converters (ADCs) with low bit resolutions, on single- and multi-carrier block transmission systems in wireless multipath environments. We consider single carrier block transmission with frequency domai

  9. Design of wireless video transmission system based on STM32 microcontroller

    Science.gov (United States)

    Yang, Fan; Ma, Chunting; Li, Haoyi

    2017-03-01

    The design of a wireless video transmission system based on STM32, the system uses the STM32F103VET6 microprocessor as the core, through the video acquisition module collects video data, video data will be sent to the receiver through the wireless transmitting module, receiving data will be displayed on the LCD screen. The software design process of receiver and transmitter is introduced. The experiment proves that the system realizes wireless video transmission function.

  10. Wideband Analog Transmission System Based on the External Intensity Electro-Optic Modulator

    Directory of Open Access Journals (Sweden)

    Jiri Svarny

    2016-01-01

    Full Text Available The work deals with design and integration of an analog electro-optic transmission system suitable for some specialized tasks of diagnostics and measurements. The system is based on principle of external intensity modulation of fiber guided laser radiation. Besides wideband and almost lossless transmission the system tolerates extreme length of the transmitting medium and ensures ultimate galvanic barrier between the input and output.

  11. Noise and signal interference in optical fiber transmission systems an optimum design approach

    CERN Document Server

    Bottacchi, Stefano

    2008-01-01

    A comprehensive reference to noise and signal interference in optical fiber communications Noise and Signal Interference in Optical Fiber Transmission Systems is a compendium on specific topics within optical fiber transmission and the optimization process of the system design. It offers comprehensive treatment of noise and intersymbol interference (ISI) components affecting optical fiber communications systems, containing coverage on noise from the light source, the fiber and the receiver. The ISI is modeled with a statistical approach, leading to new useful computational m

  12. No apparent reduction in schistosome burden or genetic diversity following four years of school-based mass drug administration in mwea, central kenya, a heavy transmission area.

    Directory of Open Access Journals (Sweden)

    Agola E Lelo

    2014-10-01

    Full Text Available Schistosomiasis is a debilitating neglected tropical disease that infects over 200 million people worldwide. To combat this disease, in 2012, the World Health Organization announced a goal of reducing and eliminating transmission of schistosomes. Current control focuses primarily on mass drug administration (MDA. Therefore, we monitored transmission of Schistosoma mansoni via fecal egg counts and genetic markers in a typical school based MDA setting to ascertain the actual impacts of MDA on the targeted schistosome population.For 4 years, we followed 67 children enrolled in a MDA program in Kenya. Infection status and egg counts were measured each year prior to treatment. For 15 of these children, for which there was no evidence of acquired resistance, meaning they became re-infected following each treatment, we collected microsatellite genotype data from schistosomes passed in fecal samples as a representation of the force of transmission between drug treatments. We genotyped a total of 4938 parasites from these children, with an average of 329.2 parasites per child for the entire study, and an average of 82.3 parasites per child per annual examination. We compared prevalence, egg counts, and genetic measures including allelic richness, gene diversity (expected heterozygosity, adult worm burdens and effective number of breeders among time points to search for evidence for a change in transmission or schistosome populations during the MDA program.We found no evidence of reduced transmission or schistosome population decline over the course of the program. Although prevalence declined in the 67 children as it did in the overall program, reinfection rates were high, and for the 15 children studied in detail, schistosome egg counts and estimated adult worm burdens did not decline between years 1 and 4, and genetic diversity increased over the course of drug treatment.School based control programs undoubtedly improve the health of individuals

  13. Analysis of Bifurcation and Nonlinear Control for Chaos in Gear Transmission System

    Directory of Open Access Journals (Sweden)

    Wang Jingyue

    2013-07-01

    Full Text Available In order to study the bifurcation characteristics and control chaotic vibration of the gear transmission system. The complex dynamics characters of gear transmission system are studied. The dynamical equation and the state equation of gear transmission system are established according to Newton's rule. The route to chaos of the system is studied by the bifurcation diagram, phase portrait, time course diagram and Poincaré map. A method of controlling chaos by nonlinear feedback controller is developed to guide chaotic motions towards regular motions. Numerical simulation shows that with the increase of meshing stiffness, gear transmission system will be from the periodic motion to chaotic motion by doubling bifurcation, the effectiveness and feasibility of the strategy to get rid of chaos by stabilizing the related unstable periodic orbit.

  14. Research and Development of Engine-Generator Set Control System for Tracked Vehicle Electric Transmission System

    Institute of Scientific and Technical Information of China (English)

    HUANG Ying; HUANG Qian; SUN Feng-chun; LIU Bo-lan; LIU Jia

    2007-01-01

    As an energy generating equipment, the engine-generator set supplies power to the electric transmission. Therefore, its control is one of the key technologies of electric vehicles. Based on the discussion about the demands to the engine-generator set in tracked vehicles, the detailed function of engine-generator and the control strategy are determined. The hardware and software of the control system are also developed and tested in a prototype vehicle. The experiment results show that the control system has good reliability and can satisfy the power requirements of vehicles under all operating conditions.

  15. Control system of the physical simulation for the HVDC transmission system

    Science.gov (United States)

    Liu, Zheng; Huang, Tongyuan; Liu, Wei; Ai, Bing; Mou, Daohuai

    2007-12-01

    The intention of this paper is to present the control system of the physical simulation for the Three Gorges HVDC transmission system. It covers all essential control functions which are involved in the continuously working power flow control and power modulation including converter firing and pole current control. This system include two convert stations, They design the fault arbitrator for the dual-controller system based on fault-tolerant technology and figure-safety-comparing technology. The arbitrator can endure long working time with high reliability. Controller A and B not only works independent, but also can controlled by the master controller from CAN bus. At the same time, because the master controller is a industrial PC, we can easy adjust and enhance the functions. This characteristic is especially fit the physical simulation system.

  16. Evaluation of power system security and development of transmission pricing method

    Science.gov (United States)

    Kim, Hyungchul

    The electric power utility industry is presently undergoing a change towards the deregulated environment. This has resulted in unbundling of generation, transmission and distribution services. The introduction of competition into unbundled electricity services may lead system operation closer to its security boundaries resulting in smaller operating safety margins. The competitive environment is expected to lead to lower price rates for customers and higher efficiency for power suppliers in the long run. Under this deregulated environment, security assessment and pricing of transmission services have become important issues in power systems. This dissertation provides new methods for power system security assessment and transmission pricing. In power system security assessment, the following issues are discussed (1) The description of probabilistic methods for power system security assessment; (2) The computation time of simulation methods; (3) on-line security assessment for operation. A probabilistic method using Monte-Carlo simulation is proposed for power system security assessment. This method takes into account dynamic and static effects corresponding to contingencies. Two different Kohonen networks, Self-Organizing Maps and Learning Vector Quantization, are employed to speed up the probabilistic method. The combination of Kohonen networks and Monte-Carlo simulation can reduce computation time in comparison with straight Monte-Carlo simulation. A technique for security assessment employing Bayes classifier is also proposed. This method can be useful for system operators to make security decisions during on-line power system operation. This dissertation also suggests an approach for allocating transmission transaction costs based on reliability benefits in transmission services. The proposed method shows the transmission transaction cost of reliability benefits when transmission line capacities are considered. The ratio between allocation by transmission line

  17. A Study on the Application for Enhancing the Transmission Capability of the KEPCO Power System

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Han; Kwon, Tea Won; Whang, Jong Young; Lee, Gun Joon; Kim, Tae Hoon; Chang, Byung Hoon; Min, Wan Ki [Korea Electric Power Research Institute, Taejon (Korea, Republic of); Park, Young Moon; Park, Jong Gun [Seoul National University, Seoul (Korea, Republic of); Kim, Gun Joong [Chungnam National University, Taejon (Korea, Republic of); Oh, Tae Kwu; Choi, Kwu Hyung [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1996-12-31

    Investigation of stability for power system in 2000 year and 2006 year by using the analysis of real power system. Comparative investigation of the conventional transmission line upgrading methods such as HVDC, HOP, new conductor scheme. Investigation of FACTS, the recent transmission line upgrading method, with respect to the aspect of technique and cost and effect analysis when this method is applied to real power system. Development of the evaluation method of transmission type that should be considered when above method is applied to real power system with respect to aspect of technique and cost. Development of a long-range plan for the transmission capacity upgrading and the evaluation method of reliability. (author).

  18. Training-based Channel Estimation for Signal Equalization and OPM in 16-QAM Optical Transmission Systems

    DEFF Research Database (Denmark)

    Pittalà, Fabio; Hauske, Fabian N.; Ye, Yabin;

    2012-01-01

    Efficient channel estimation for signal equalization and OPM based on short CAZAC sequences with QPSK and 8PSK constellation formats is demonstrated in a 224-Gb/s PDM 16-QAM optical linear transmission system....

  19. The effect analysis of strain rate on power transmission tower-line system under seismic excitation.

    Science.gov (United States)

    Tian, Li; Wang, Wenming; Qian, Hui

    2014-01-01

    The effect analysis of strain rate on power transmission tower-line system under seismic excitation is studied in this paper. A three-dimensional finite element model of a transmission tower-line system is created based on a real project. Using theoretical analysis and numerical simulation, incremental dynamic analysis of the power transmission tower-line system is conducted to investigate the effect of strain rate on the nonlinear responses of the transmission tower and line. The results show that the effect of strain rate on the transmission tower generally decreases the maximum top displacements, but it would increase the maximum base shear forces, and thus it is necessary to consider the effect of strain rate on the seismic analysis of the transmission tower. The effect of strain rate could be ignored for the seismic analysis of the conductors and ground lines, but the responses of the ground lines considering strain rate effect are larger than those of the conductors. The results could provide a reference for the seismic design of the transmission tower-line system.

  20. Federal Emergency Management Information System (FEMIS) system administration guide. Version 1.4

    Energy Technology Data Exchange (ETDEWEB)

    Arp, J.A.; Burnett, R.A.; Downing, T.R. [and others

    1997-11-21

    The Federal Emergency Management Information System (FEMIS) is an emergency management planning and analysis tool that was developed by the Pacific Northwest National Laboratory (PNNL) under the direction of the US Army Chemical Biological Defense Command. The FEMIS System Administration Guide defines FEMIS hardware and software requirements and gives instructions for installing the FEMIS software package. This document also contains information on the following: software installation for the FEMIS data servers, communication server, mail server, and the emergency management workstations; distribution media loading and FEMIS installation validation and troubleshooting; and system management of FEMIS users, login privileges, and usage. The system administration utilities (tools), available in the FEMIS client software, are described for user accounts and site profile. This document also describes the installation and use of system and database administration utilities that will assist in keeping the FEMIS system running in an operational environment. The FEMIS system is designed for a single Chemical Stockpile Emergency Preparedness Program (CSEPP) site that has multiple Emergency Operations Centers (EOCs). Each EOC has personal computers (PCs) that emergency planners and operations personnel use to do their jobs. These PCs are connected via a local area network (LAN) to servers that provide EOC-wide services. Each EOC is interconnected to other EOCs via telecommunications links.

  1. Systemic administration of erythropoietin inhibits retinopathy in RCS rats.

    Directory of Open Access Journals (Sweden)

    Weiyong Shen

    Full Text Available OBJECTIVE: Royal College of Surgeons (RCS rats develop vasculopathy as photoreceptors degenerate. The aim of this study was to examine the effect of erythropoietin (EPO on retinopathy in RCS rats. METHODS: Fluorescein angiography was used to monitor retinal vascular changes over time. Changes in retinal glia and vasculature were studied by immunostaining. To study the effects of EPO on retinal pathology, EPO (5000 IU/kg was injected intraperitoneally in 14 week old normal and RCS rats twice a week for 4 weeks. Changes in the retinal vasculature, glia and microglia, photoreceptor apoptosis, differential expression of p75 neurotrophin receptor (p75NTR, pro-neurotrophin 3 (pro-NT3, tumour necrosis factor-α (TNFα, pigment epithelium derived factor (PEDF and vascular endothelial growth factor-A (VEGF-A, the production of CD34(+ cells and mobilization of CD34(+/VEGF-R2(+ cells as well as recruitment of CD34(+ cells into the retina were examined after EPO treatment. RESULTS: RCS rats developed progressive capillary dropout and subretinal neovascularization which were accompanied by retinal gliosis. Systemic administration of EPO stabilized the retinal vasculature and inhibited the development of focal vascular lesions. Further studies showed that EPO modulated retinal gliosis, attenuated photoreceptor apoptosis and p75NTR and pro-NT3 upregulation, promoted the infiltration of ramified microglia and stimulated VEGF-A expression but had little effect on TNFα and PEDF expression. EPO stimulated the production of red and white blood cells and CD34(+ cells along with effective mobilization of CD34(+/VEGF-R2(+ cells. Immunofluorescence study demonstrated that EPO enhanced the recruitment of CD34+ cells into the retina. CONCLUSIONS: Our results suggest that EPO has therapeutic potentials in treatment of neuronal and vascular pathology in retinal disease. The protective effects of EPO on photoreceptors and the retinal vasculature may involve multiple

  2. System Design for Ocean Sensor Data Transmission Based on Inductive Coupling

    Science.gov (United States)

    Xu, Ming; Liu, Fei; Zong, Yuan; Hong, Feng

    Ocean observation is the precondition to explore and utilize ocean. How to acquire ocean data in a precise, efficient and real-time way is the key question of ocean surveillance. Traditionally, there are three types of methods for ocean data transmission: underwater acoustic, GPRS via mobile network and satellite communication. However, none of them can meet the requirements of efficiency, accuracy, real-time and low cost at the same time. In this paper, we propose a new wireless transmission system for underwater sensors, which established on FGR wireless modules, combined with inductive coupling lab and offshore experiments confirmed the feasibility and effectiveness of the proposed wireless transmission system.

  3. Electrical transmission systems and smart grids selected entries from the encyclopedia of sustainability science and technology

    CERN Document Server

    Begovic, Miroslav M

    2012-01-01

    Electric transmission networks are among the largest human-made engineering systems: For example, the transmission network in the United States covers over 300,000 km of lines and is served by 500 companies (electric utilities). In sharp contrast to the very incremental developments of the last century, transmission and control technologies experienced a major breakthrough at the beginning of the 21st century. The rapid growth of new energy generation technologies (renewables), significant advances in information processing applied to system monitoring, planning, operation, control, and protec

  4. Transmission Dynamics of a Driven Two-Level System Dissipated by Leads

    Institute of Scientific and Technical Information of China (English)

    ZHANG Ping; FAN Wen-Bin; ZHAO Xian-Geng

    2001-01-01

    We study the transmission dynamics of a driven two-level system dissipated by the two leads. Using the nonequilibrium Green function, we derive an analytical transmission formula for an electron incident from the left lead,through the double quantum dots, to the right lead. The Landauer-type conductance and current are also given.A discussion of the internal tunnelling dynamics reveals crucial effects of the localization and delocalization on the transport of the system.

  5. The Numerical Analysis of Transmission Tower-Line System Wind-Induced Collapsed Performance

    OpenAIRE

    Zhuoqun Zhang; Hongnan Li; Gang Li; Wenming Wang; Li Tian

    2013-01-01

    The numerical simulation of transmission tower-line systems' progressive collapse performance is considered as a major research hotspot and significant project, due to the increasing number of wind-induced collapse accidents recently. In this study, the finite element models for single tower and transmission tower-line system were established to simulate wind-induced progressive collapse by birth-to-death element technique in ABAQUS/Explicit. The wind field, based on the Kaimal fluctuating wi...

  6. Simulation on Dual-stream Transmission System of Unmanned Tracked Armored Vehicle Using ADAMS

    Directory of Open Access Journals (Sweden)

    Sun Wei

    2015-01-01

    Full Text Available For the dual-stream transmission system of unmanned tracked armored vehicle, simulation analysis is carried out. Using SolidWorks to establish three-dimensional model of its chassis, the result of the simulation is processed in AdAMS/Solver. The simulation results are showed in lines. Comparative analysis for each simulation lines is conducted, and it verifies the feasibility of the dual-stream transmission system.

  7. Modular VSC converter based HVDC power transmission from offshore wind power plant: Compared to the conventional HVAC system

    DEFF Research Database (Denmark)

    Sharma, Ranjan; Rasmussen, Tonny Wederberg; Jensen, Kim Høj;

    2010-01-01

    power transmission options with HVDC systems are under consideration. In this paper, a comparison between a conventional HVAC transmission system and a HVDC system equipped with modular voltage source converters is provided. The comparison is based on the total energy transmission capability...

  8. SUNRA - a sustainability rating system framework for National Road Administrations

    DEFF Research Database (Denmark)

    Sowerby, Chris; Langstraat, James; Harmer, Clare;

    National Road Administrations (NRAs) across Europe strive to improve the performance of their road networks. This improvement has been underpinned by significant research in the optimisation of road planning, design, construction and maintenance, which has enhanced the understanding of the social...

  9. Massive WDM and TDM Soliton Transmission Systems : a ROSC Symposium

    CERN Document Server

    2002-01-01

    This book summarizes the proceedings of the invited talks presented at the “International Symposium on Massive TDM and WDM Optical Soliton Tra- mission Systems” held in Kyoto during November 9–12, 1999. The symposium is the third of the series organized by Research Group for Optical Soliton C- munications (ROSC) chaired by Akira Hasegawa. The research group, ROSC, was established in Japan in April 1995 with a support of the Japanese Ministry of Post and Telecommunications to promote collaboration and information - change among communication service companies, communication industries and academic circles in the theory and application of optical solitons. The symposium attracted enthusiastic response from worldwide researchers in the field of soliton based communications and intensive discussions were made. In the symposium held in 1997, new concept of soliton transmission based on dispersion management of optical fibers were presented. This new soliton is now called the dispersion managed soliton. The p...

  10. Single Ended Fault Location Estimation for EHV Transmission Systems

    Institute of Scientific and Technical Information of China (English)

    ZHANG Qing-chao张庆超; LI Hui李晖; D. W. P. Thomas

    2004-01-01

    A novel numerical algorithm for fault location estimation of single-phase-to-earth fault on EHV transmission lines is presented in this paper. The method is based on one-terminal voltage and current data and is used in a procedure that provides the automatic determination of faulted types and phases, rather than requires engineer to specify them. The loop and nodal equations comparing the faulted phase to non-faulted phases of multi-parallel lines are introduced in the fault location estimation models, in which source impedance of remote end is not involved. Precise algorithms of locating fault are derived. The effect of load flow and fault resistance,on the location accuracy, are effectively eliminated. The algorithms are demonstrated by digital computer simulations.

  11. Transmission systems expansion planning considering security and generation programming plans

    OpenAIRE

    Irenio de Jesus Silva Junior

    2005-01-01

    Resumo: Este trabalho apresenta algumas propostas para solucionar o problema de planejamento da expansão de sistemas de transmissão, estático e multiestágio, considerando restrições de segurança - critério de segurança (n_1), assim como para o planejamento da expansão de um sistema elétrico que satisfaça simultaneamente vários planos de programação da geração pré-especificados. Visando superar deficiências na determinação de soluções ótimas para sistemas de grande porte quando se usa métodos ...

  12. Systemic administration of 3-bromopyruvate in treating disseminated aggressive lymphoma.

    Science.gov (United States)

    Schaefer, Niklaus G; Geschwind, Jean F; Engles, James; Buchanan, Julia W; Wahl, Richard L

    2012-01-01

    toxicity of the daily administration of 10 mg/kg 3-BrPA was a reduction in body weight. Body weight at day 0 was 17.22 g ± 0.84 g in the treatment group and 17.58 g ± 0.86 g in the control group. Body weight at day +6 was 15.02 g ± 2.04 g in the treated group and 19.4 g ± 0.63 g in the control group. 3-BrPA demonstrated a significant positive tumor response both in vitro and in vivo. This, to our knowledge, is the first report of the use of 3-BrPA in a systemic tumor model. Based on these data, 3-BrPA holds promise for treatment of systemic metastatic cancers.

  13. LQR Feedback Control Development for Wind Turbines Featuring a Digital Fluid Power Transmission System

    DEFF Research Database (Denmark)

    Pedersen, Niels Henrik; Johansen, Per; Andersen, Torben O.

    2016-01-01

    Research within digital fluid power (DFP) transmissions is receiving an increased attention as an alternative to conventional transmission technologies. The use of DFP displacement machines entail a need for applicable control algorithms. However, the design and analysis of controllers...... for such digital systems are complicated by its non-smooth behavior. In this paper a control design approach for a digital displacement machine® is proposed and a performance analysis of a wind turbine using a DFP transmission is presented. The performance evaluation is based on a dynamic model of the transmission...... invariant model. Using full-field flow wind profiles as input, the design approach and control performance is verified by simulation in the dynamic model of the wind turbine featuring the DFP transmission. Additionally, the performance is compared to that of the conventional NREL reference turbine...

  14. [Study on transmission efficiency of interference system in spatially modulated Fourier transform spectrometer].

    Science.gov (United States)

    Lü, Jin-Guang; Liang, Jing-Qiu; Liang, Zhong-Zhu; Qin, Yu-Xin; Tian, Chao

    2013-03-01

    The reflection of the optic system surface and the absorption of the infrared material could reduce the transmission of the incident light in spatially modulated Fourier transform infrared spectrometer. Through the calculation of the transmission function of the interference system and the simulation of the interferogram image and recovered spectrum affected by transmission function, it was indicated that the contrast of the interferogram image declined and the spectral line intensity weakened. The theoretical analysis shows that the contrast of the interferogram image was related to the intensity reflectance of the anti-reflection film, and the attenuation of the spectrum was determined by transmission efficiency concerned with intensity reflectance R1 of the anti-reflection film, intensity reflectance R2 of the beam splitter film, and the absorption coefficient. By means of the analysis and argumentation, the absorption of the material could be ignored in our investigative wave band. So the transmission efficiency was determined only by R1 and R2. Then taking the transmission efficiency as the design target, according to the transmission required by system, the tolerance of the R1 and R2 could be gained.

  15. Load speed regulation in compliant mechanical transmission systems using feedback and feedforward control actions.

    Science.gov (United States)

    Raul, P R; Dwivedula, R V; Pagilla, P R

    2016-07-01

    The problem of controlling the load speed of a mechanical transmission system consisting of a belt-pulley and gear-pair is considered. The system is modeled as two inertia (motor and load) connected by a compliant transmission. If the transmission is assumed to be rigid, then using either the motor or load speed feedback provides the same result. However, with transmission compliance, due to belts or long shafts, the stability characteristics and performance of the closed-loop system are quite different when either motor or load speed feedback is employed. We investigate motor and load speed feedback schemes by utilizing the singular perturbation method. We propose and discuss a control scheme that utilizes both motor and load speed feedback, and design an adaptive feedforward action to reject load torque disturbances. The control algorithms are implemented on an experimental platform that is typically used in roll-to-roll manufacturing and results are shown and discussed.

  16. Analysis of Interline Power Flow Controller (IPFC Location in Power Transmission Systems

    Directory of Open Access Journals (Sweden)

    Amir Kahyaei

    2011-07-01

    Full Text Available The Interline Power Flow Controller (IPFC is one of the latest generation Flexible AC Transmission Systems (FACTS controller used to control power flows of multiple transmission lines. The aim of this paper is investigation of the effect of location of IPFC on profile of voltage and real and reactive power flow in transmission lines in power system. This model is incorporated in Newton- Raphson (NR power flow algorithm to study the power flow control in transmission lines in which IPFC is placed. A program in MATLAB/SIMULINK has been written in order to extend conventional NR algorithm based on this model. Numerical results are carried out on a standard power system. The results without and with IPFC for various locations are compared in terms of voltages, active and reactive power flows to demonstrate the performance of the IPFC model.

  17. Cost estimation of HVDC transmission system of Bangka’s NPP candidates

    Energy Technology Data Exchange (ETDEWEB)

    Liun, Edwaren, E-mail: edwaren@batan.go.id; Suparman, E-mail: edwaren@batan.go.id [Centre for Nuclear Energy Development, National Nuclear Energy Agency of Indonesia (Indonesia)

    2014-09-30

    Regarding nuclear power plant development in Bangka Island, it can be estimated that produced power will be oversupply for the Bangka Island and needs to transmit to Sumatra or Java Island. The distance between the regions or islands causing considerable loss of power in transmission by alternating current, and a wide range of technical and economical issues. The objective of this paper addresses to economics analysis of direct current transmission system to overcome those technical problem. Direct current transmission has a stable characteristic, so that the power delivery from Bangka to Sumatra or Java in a large scale efficiently and reliably can be done. HVDC system costs depend on the power capacity applied to the system and length of the transmission line in addition to other variables that may be different.

  18. High-voltage transmission tower-line system subjected to disaster loads

    Institute of Scientific and Technical Information of China (English)

    LI Hongnan; BAI Haifeng

    2006-01-01

    The high-voltage power transmission system is an important lifeline structure. It is significant for wide researches on the features and ability of the system subjected to earthquake and environmental loads. The promising prosperity of the system has been demonstrated around the world. The corresponding advances of the system with respect to the mechanism of loading action, analytical methods, experimental research measurements, structural vibration control, fatigue damage, lifetime prediction, and design methods are comprehensively discussed herein. Finally, further research work on dynamic response characteristics of high-voltage transmission towerline system in the near future is predicted.

  19. 47 CFR 73.1350 - Transmission system operation.

    Science.gov (United States)

    2010-10-01

    ... regarding antenna tower lighting, and § 73.69 regarding the parameters of an AM directional antenna system... system tolerances, see § 73.62; (2) AM directional antenna monitoring points, see § 73.158; (3) TV...

  20. Microwave power transmission system workshop, session on solid state

    Science.gov (United States)

    Finnell, W.

    1980-01-01

    The development of solid state technology for solar power satellite systems is briefly addressed. The economic advantages of solid state based systems are listed along with some conclusions and issues regarding specific design concepts.

  1. Ethosomes as delivery system for transdermal administration of vinpocetine.

    Science.gov (United States)

    Mao, Yan-Ting; Hua, Hai-Ying; Zhang, Xiang-Guo; Zhu, Dong-Xue; Li, Feng; Gui, Zhen-Hua; Zhao, Yong-Xing

    2013-05-01

    The purpose of the present study was to develop a novel transdermal vinpocetine patch containing a stable formulation and with good entrapment efficiency, and percutaneous absorption which via ethosome. Ethosome was found to be a more efficient delivery carrier with high encapsulation capacities (79.5% +/- 1.8%) and nanometric size (180.7 +/- 1.5 nm). In vitro percutaneous permeation experiments demonstrated that the permeation of vinpocetine through abdominal skin of Sprague Dawley was significantly increased when ethosome was used. The vinpocetine transdermal fluxes from ethosome gel (3.56 +/- 0.13 microg/cm2/h) were 6.72 and 3.10 times higher than that of vinpocetine gel solution and vinpocetine aueous solution, respectively. Furthermore, the AUC(0 --> infinity), and eliminiation half-life by the transdermal administration were significantly higher than those by the intragastric administration (P ethosome is a promising vesicular carrier for enhancing percutaneous absorption of vinpocetine.

  2. Data model for the collaboration between land administration systems and agricultural land parcel identification systems.

    Science.gov (United States)

    Inan, Halil Ibrahim; Sagris, Valentina; Devos, Wim; Milenov, Pavel; van Oosterom, Peter; Zevenbergen, Jaap

    2010-12-01

    The Common Agricultural Policy (CAP) of the European Union (EU) has dramatically changed after 1992, and from then on the CAP focused on the management of direct income subsidies instead of production-based subsidies. For this focus, Member States (MS) are expected to establish Integrated Administration and Control System (IACS), including a Land Parcel Identification System (LPIS) as the spatial part of IACS. Different MS have chosen different solutions for their LPIS. Currently, some MS based their IACS/LPIS on data from their Land Administration Systems (LAS), and many others use purpose built special systems for their IACS/LPIS. The issue with these different IACS/LPIS is that they do not have standardized structures; rather, each represents a unique design in each MS, both in the case of LAS based or special systems. In this study, we aim at designing a core data model for those IACS/LPIS based on LAS. For this purpose, we make use of the ongoing standardization initiatives for LAS (Land Administration Domain Model: LADM) and IACS/LPIS (LPIS Core Model: LCM). The data model we propose in this study implies the collaboration between LADM and LCM and includes some extensions. Some basic issues with the collaboration model are discussed within this study: registration of farmers, land use rights and farming limitations, geometry/topology, temporal data management etc. For further explanation of the model structure, sample instance level diagrams illustrating some typical situations are also included.

  3. Electrical Collection and Transmission Systems for Offshore Wind Power: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Green, J.; Bowen, A.; Fingersh, L.J.; Wan, Y.

    2007-03-01

    The electrical systems needed for offshore wind farms to collect power from wind turbines--and transmit it to shore--will be a significant cost element of these systems. This paper describes the development of a simplified model of the cost and performance of such systems.

  4. Systemic uptake of buprenorphine by cats after oral mucosal administration.

    Science.gov (United States)

    Robertson, S A; Taylor, P M; Sear, J W

    2003-05-31

    The plasma concentration of buprenorphine was measured by radioimmunoassay in six female cats after the administration of 0.01 mg/kg (0.033 ml/kg) buprenorphine hydrochloride solution into the side of the cat's mouth. Blood samples were taken through a preplaced jugular catheter before and one, two, four, six, 10, 15, 30, 45 and 60 minutes, and two, four, six, 12 and 24 hours after the dose was administered. The buprenorphine was accepted well by all the cats and did not cause salivation or vomiting. Its median peak plasma concentration was 7.5 ng/ml and was reached after 15 minutes. The pharmacokinetic data were similar to the pharmacokinetic data obtained after the intramuscular and intravenous administration of buprenorphine to cats from the same colony, suggesting that the mucosal route of administration should be as effective as intravenous and intramuscular injections. In addition, the pH of the oral cavity of 26 cats was measured with pH paper, and 100 cat owners were asked their preferred method of administering drugs to cats. The pH of the cats' mouths was between 8 and 9, and the technique preferred by the cat owners was the use of drops placed in the mouth.

  5. An analysis of reform in administrative system of Chinese higher education

    Institute of Scientific and Technical Information of China (English)

    Hu Jian-hua

    2006-01-01

    After the founding of the People's Republic of China,the administrative system of higher education then was characterized as"centra lized","Tiao and Kuai"were segmented (some higher education institutions were directly administered by provincial govemments,and some were affiliated to the relative administrative departments of the state) and higher education institutions (HEIs) were government-run.The reform in the administrative system of higher education launched in the 1980s broke down the segmentation of"Tiao and Kuai",and changed it into a new administrative system emphasizing the role of the provincial governments ("Kuai-oriented mode").Thus,HEIs gained more autonomy and tremendous changes have taken place in the relation between HEIs and the government.However,weakening the government's administrative control over HEIs and readjusting government-HEIs relations are still the main concerns in reforming the administrative system of Chinese higher education.

  6. Investigations and system design for simultaneous energy and data transmission through inductively coupled resonances

    Science.gov (United States)

    Schmidt, C.; Lloret Fuentes, E.; Buchholz, M.

    2015-11-01

    Wireless Power Transfer (WPT) with simultaneous data transmission through coupled magnetic resonators is investigated in this paper. The development of this system is dedicated to serve as a basis for applications in the field of Ambient Assisted Living (AAL), for example tracking vital parameters remotely, charge and control sensors and so on. Due to these different scenarios we consider, it is important to have a system which is reliable under the circumstance of changing positioning of the receiving device. State of the art radio systems would be able to handle this. Nevertheless, energy harvesting from far field sources is not sufficient to power the devices additionally on mid-range distances. For this reason, coupled magnetic resonant circuits are proposed as a promising alternative, although suffering from more complex positioning dependency. Based on measurements on a simple prototype system, an equivalent circuit description is used to model the transmission system dependent on different transmission distances and impedance matching conditions. Additionally, the simulation model is used to extract system parameters such as coupling coefficients, coil resistance and self-capacitance, which cannot be calculated in a simple and reliable way. Furthermore, a mathematical channel model based on the schematic model has been built in MATLAB©. It is used to point out the problems occurring in a transmission system with variable transmission distance, especially the change of the passband's centre frequency and its bandwidth. Existing solutions dealing with this distance dependent behaviour, namely the change of the transmission frequency dependent on distance and the addition of losses to the resonators to increase the bandwidth, are considered as not inventive. First, changing the transmission frequency increases the complexity in the data transmission system and would use a disproportional total bandwidth compared to the actually available bandwidth

  7. Optimisation of Transmission Systems by use of Phase Shifting Transformers

    Energy Technology Data Exchange (ETDEWEB)

    Verboomen, J.

    2008-10-13

    In this thesis, transmission grids with PSTs (Phase Shifting Transformers) are investigated. In particular, the following goals are put forward: (a) The analysis and quantification of the impact of a PST on a meshed grid. This includes the development of models for the device; (b) The development of methods to obtain optimal coordination of several PSTs in a meshed grid. An objective function should be formulated, and an optimisation method must be adopted to solve the problem; and (c) The investigation of different strategies to use a PST. Chapter 2 gives a short overview of active power flow controlling devices. In chapter 3, a first step towards optimal PST coordination is taken. In chapter 4, metaheuristic optimisation methods are discussed. Chapter 5 introduces DC load flow approximations, leading to analytically closed equations that describe the relation between PST settings and active power flows. In chapter 6, some applications of the methods that are developed in earlier chapters are presented. Chapter 7 contains the conclusions of this thesis, as well as recommendations for future work.

  8. Effect of Tooth Profile Modification on Vibration of Power Split Gear Transmission System

    Institute of Scientific and Technical Information of China (English)

    He Lin

    2016-01-01

    Based on Newton's second law, the bend⁃torsion⁃shaft coupling nonlinear dynamic model and equations of power split gear transmission system are established. According to the principle of tooth profile modification, the tooth profile modification is considered as time⁃varying gear backlash function acting along the line of action. Then the dynamic functions are solved by using Runge⁃Kutta numerical method. After analyzing the effect of tooth profile modification quantity( TPMQ) and relative tooth profile modification length( TPML) to the nonlinear dynamic characteristics of power split gear transmission, the following conclusions are drawn:①The TPMQ of a certain stage transmission affects the vibration of its own stage more significantly than the other stage, and the coupling effect between two stages can be ignored usually in the modification design;②If the first stage TPMLs are less than 0.3, the influence of the first stage TPMLs to the first stage transmission vibration is much more greatly than the influence of the second stage TPMLs to the first stage transmission vibration, or else both the first and second stage TPMLs affect the first stage transmission vibration largely. The same is true for the second stage TPMLs, and the cutoff value is 0. 2; ③The TPMQ affects the vibration of power split gear transmission system more principally than the TPML, and should be top⁃priority in the modification design.

  9. Expedience of application of MIMO systems of digital communication for complex chaotic signal transmission

    OpenAIRE

    Vasyuta, K. S.; Zakharchenko, I. V.; Ozerov, S. V.

    2015-01-01

    The paper discusses the expediency of using MIMO digital systems for transmission of chaotic signals as a way of partial solution of electromagnetic compatibility of perspective broadband communication systems with an existing class of narrow-band radio-technical systems.

  10. Transmission Needs In A Fully Renewable Pan-European Electricity System

    DEFF Research Database (Denmark)

    Rodriguez, Rolando A.; Bruun Andresen, Gorm; Becker, Sarah;

    2012-01-01

    Based on high-resolution weather and electrical load data, the transmission needs for a fully renewable pan-European electricity system are determined. The ideal cross-border transmission capacities turn out to be a factor 10 larger than those of today. A reduction of cross-border transmission...... capacities lead to a non-linear increase of balancing needs. A good compromise turns out to be a capacity layout, which is a factor 5 larger than today’s one. On average each country will only be able to import / export 40% of its residual demand / renewable excess generation....

  11. Optimal transmission strategy for spatially correlated MIMO systems with channel statistical information

    Institute of Scientific and Technical Information of China (English)

    ZHAO Zhen-shan; XU Guo-zhi

    2007-01-01

    In real multiple-input multiple-output (MIMO) systems, the perfect channel state information (CSI) may be costly or impossible to acquire. But the channel statistical information can be considered relatively stationary during long-term transmission.The statistical information can be obtained at the receiver and fed back to the transmitter and do not require frequent update. By exploiting channel mean and covariance information at the transmitter simultaneously, this paper investigates the optimal transmission strategy for spatially correlated MIMO channels. An upper bound of ergodic capacity is derived and taken as the performance criterion. Simulation results are also given to show the performance improvement of the optimal transmission strategy.

  12. Design, control and application of modular multilevel converters for HVDC transmission systems

    CERN Document Server

    Sharifabadi, Kamran; Nee, Hans-Peter; Norrga, Staffan; Teodorescu, Remus

    2016-01-01

    Design, Control and Application of Modular Multilevel Converters for HVDC Transmission Systems is a comprehensive guide to semiconductor technologies applicable for MMC design, component sizing control, modulation, and application of the MMC technology for HVDC transmission. Separated into three distinct parts, the first offers an overview of MMC technology, including information on converter component sizing, Control and Communication, Protection and Fault Management, and Generic Modelling and Simulation. The second covers the applications of MMC in offshore WPP, including planning, technical and economic requirements and optimization options, fault management, dynamic and transient stability. Finally, the third chapter explores the applications of MMC in HVDC transmission and Multi Terminal configurations, including Supergrids.

  13. Disaster Management: AN Integral Part of Science & Technology System and Land Administration-Management System

    Science.gov (United States)

    Ghawana, T.; Zlatanova, S.

    2016-06-01

    Disaster management is a multidisciplinary field, which requires a general coordination approach as well as specialist approaches. Science and Technology system of a country allows to create policies and execution of technical inputs required which provide services for the specific types of disasters management. Land administration and management agencies, as the administrative and management bodies, focus more on the coordination of designated tasks to various agencies responsible for their dedicated roles. They get help from Scientific and technical inputs & policies which require to be implemented in a professional manner. The paper provides an example of such integration from India where these two systems complement each other with their dedicated services. Delhi, the Capital of India, has such a disaster management system which has lot of technical departments of government which are mandated to provide their services as Emergency Service Functionaries. Thus, it is shown that disaster management is a job which is an integral part of Science & Technology system of a country while being implemented primarily with the help of land administration and management agencies. It is required that new policies or mandates for the Science and technology organizations of government should give a primary space to disaster management

  14. Design of the Eelectron Cyclotron Resonance Heating Transmission System for HL-2A

    Institute of Scientific and Technical Information of China (English)

    周俊; 刘永

    2004-01-01

    HL-2A will be equipped with a 75 GHz/1 MW/1s electron cyclotron resonance heating (ECRH) system. The paper describes the design of the transmission system, which is made up of a transmission line, an equatorial launcher and a measureing system. The paper describes in detail the design of main components of the system such as, waveguides, ellipsoidal surface mirrors, chemical vapor (CVD) diamond window, steering mirror, and new directional coupler with a k-spectrometer. The newly-designed launcher can make the beam steer poloidally to deposit energy in different locations.

  15. Research on WDM optical fiber transmission system based on fiber Raman amplifier

    Institute of Scientific and Technical Information of China (English)

    Fei Xue(薛飞); Kun Qiu(邱昆); Yue Chen(陈玥)

    2003-01-01

    After wavelength division multiplexing (WDM) optical fiber transmission system based on fiber Raman amplifier (FRA) is investigated in detail, the influence of the collocation of dispersion compensation fiber (DCF), the dispersion coefficient, dispersion slope (DS), effective core area, nonlinear index, length of FRA, launch power and the bandwidth of Bessel filter on bit error rate (BER) is deduced. The influence of Rayleigh backscattering noise on optical signal noise ratio (OSNR) is also investigated, which affects the performance of long haul transmission badly. The result indicates that the broadband long haul transmission can be realized through the reasonable design of the fiber. The result is useful to the optimal design of the WDM optical fiber transmission system based on FRA.

  16. The design and analysis of channel transmission communication system of XCTD profiler.

    Science.gov (United States)

    Zheng, Yu; Wang, Xiao-Rui; Jin, Xiang-Yu; Song, Guo-Min; Shang, Ying-Sheng; Li, Hong-Zhi

    2016-10-01

    In this paper, a channel transmission communication system of expendable conductivity-temperature-depth is established in accordance to the operation characteristics of the transmission line to more accurately assess the characteristics of deep-sea abandoned profiler channel. The wrapping inductance is eliminated to maximum extent through the wrapping pattern of the underwater spool and the overwater spool and the calculation of the wrapping diameter. The feasibility of the proposed channel transmission communication system is verified through theoretical analysis and practical measurement of the transmission signal error rate in the amplitude shift keying (ASK) modulation. The proposed design provides a new research method for the channel assessment of complex abandoned measuring instrument and an important experiment evidence for the rapid development of the deep-sea abandoned measuring instrument.

  17. Coordinated Transmissions to Direct and Relayed Users in Wireless Cellular Systems

    CERN Document Server

    Thai, Chan Dai Truyen; Kaneko, Megumi; de Carvalho, Elisabeth

    2010-01-01

    The ideas of wireless network coding at the physical layer promise high throughput gains in wireless systems with relays and multi-way traffic flows. This gain can be ascribed to two principles: (1) joint transmission of multiple communication flows and (2) usage of \\emph{a priori} information to cancel the interference. In this paper we use these principles to devise new transmission schemes in wireless cellular systems that feature both users served directly by the base stations (direct users) and users served through relays (relayed users). We present four different schemes for \\emph{coordinated transmission} of uplink and downlink traffic in which one direct and one relayed user are served. These schemes are then used as building blocks in multi-user scenarios, where we present several schemes for scheduling pairs of users for coordinated transmissions. The optimal scheme involves exhaustive search of the best user pair in terms of overall rate. We propose several suboptimal scheduling schemes, which perf...

  18. The design and analysis of channel transmission communication system of XCTD profiler

    Science.gov (United States)

    Zheng, Yu; Wang, Xiao-Rui; Jin, Xiang-Yu; Song, Guo-Min; Shang, Ying-Sheng; Li, Hong-Zhi

    2016-10-01

    In this paper, a channel transmission communication system of expendable conductivity-temperature-depth is established in accordance to the operation characteristics of the transmission line to more accurately assess the characteristics of deep-sea abandoned profiler channel. The wrapping inductance is eliminated to maximum extent through the wrapping pattern of the underwater spool and the overwater spool and the calculation of the wrapping diameter. The feasibility of the proposed channel transmission communication system is verified through theoretical analysis and practical measurement of the transmission signal error rate in the amplitude shift keying (ASK) modulation. The proposed design provides a new research method for the channel assessment of complex abandoned measuring instrument and an important experiment evidence for the rapid development of the deep-sea abandoned measuring instrument.

  19. Hole-assisted multicore optical fiber for next generation telecom transmission systems

    Science.gov (United States)

    Ziolowicz, A.; Szymanski, M.; Szostkiewicz, L.; Tenderenda, T.; Napierala, M.; Murawski, M.; Holdynski, Z.; Ostrowski, L.; Mergo, P.; Poturaj, K.; Makara, M.; Slowikowski, M.; Pawlik, K.; Stanczyk, T.; Stepien, K.; Wysokinski, K.; Broczkowska, M.; Nasilowski, T.

    2014-08-01

    We present a multicore fiber dedicated for next generation transmission systems. To overcome the issue of multicore fibers' integration with existing transmission systems, the fiber is designed in such a way that the transmission parameters for each core (i.e., chromatic dispersion, attenuation, bending loss, etc.) are in total accordance with the obligatory standards for telecommunication single core fibers (i.e., ITU-T G.652 and G.657). We show the results of numerical investigations and measurements carried out for the fabricated fiber, which confirm low core-to-core crosstalk and compatibility with standard single-core single-mode transmission links making the fiber ready for implementation in the near future.

  20. Coordinated Transmissions to Direct and Relayed Users in Wireless Cellular Systems

    DEFF Research Database (Denmark)

    Thai, Chan; Popovski, Petar; Kaneko, Megumi

    2011-01-01

    The ideas of wireless network coding at the physical layer promise high throughput gains in wireless systems with relays and multi–way traffic flows. This gain can be ascribed to two principles: (1) joint transmission of multiple communication flows and (2) usage of a priori information to cancel...... the interference. In this paper we use these principles to devise new transmission schemes in wireless cellular systems that feature both users served directly by the base stations (direct users) and users served through relays (relayed users). We present four different schemes for coordinated transmission...... of uplink and downlink traffic in which one direct and one relayed user are served. These schemes are then used as building blocks in multi–user scenarios, where we present several schemes for scheduling pairs of users for coordinated transmissions. The optimal scheme involves exhaustive search of the best...

  1. Optogenetic stimulation of VTA dopamine neurons reveals that tonic but not phasic patterns of dopamine transmission reduce ethanol self-administration

    Directory of Open Access Journals (Sweden)

    Caroline E Bass

    2013-11-01

    Full Text Available There is compelling evidence that acute ethanol exposure stimulates ventral tegmental area (VTA dopamine cell activity and that VTA-dependent dopamine release in terminal fields within the nucleus accumbens plays an integral role in the regulation of ethanol drinking behaviors. Unfortunately, due to technical limitations, the specific temporal dynamics linking VTA dopamine cell activation and ethanol self-administration are not known. In fact, establishing a causal link between specific patterns of dopamine transmission and ethanol drinking behaviors has proven elusive. Here, we sought to address these gaps in our knowledge using a newly developed viral-mediated gene delivery strategy to selectively express Channelrhodopsin-2 (ChR2 on dopamine cells in the VTA of wild-type rats. We then used this approach to precisely control VTA dopamine transmission during voluntary ethanol drinking sessions. The results confirmed that ChR2 was selectively expressed on VTA dopamine cells and delivery of blue light pulses to the VTA induced dopamine release in accumbal terminal fields with very high temporal and spatial precision. Brief high frequency VTA stimulation induced phasic patterns of dopamine release in the nucleus accumbens. Lower frequency stimulation, applied for longer periods mimicked tonic increases in accumbal dopamine. Notably, using this optogenetic approach in rats engaged in an intermittent ethanol drinking procedure, we found that tonic, but not phasic, stimulation of VTA dopamine cells selectively attenuated ethanol drinking behaviors. Collectively, these data demonstrate the effectiveness of a novel viral targeting strategy that can be used to restrict opsin expression to dopamine cells in standard outbred animals and provide the first causal evidence demonstrating that tonic activation of VTA dopamine neurons selectively decreases ethanol self-administration behaviors.

  2. Optogenetic stimulation of VTA dopamine neurons reveals that tonic but not phasic patterns of dopamine transmission reduce ethanol self-administration.

    Science.gov (United States)

    Bass, Caroline E; Grinevich, Valentina P; Gioia, Dominic; Day-Brown, Jonathan D; Bonin, Keith D; Stuber, Garret D; Weiner, Jeff L; Budygin, Evgeny A

    2013-01-01

    There is compelling evidence that acute ethanol exposure stimulates ventral tegmental area (VTA) dopamine cell activity and that VTA-dependent dopamine release in terminal fields within the nucleus accumbens plays an integral role in the regulation of ethanol drinking behaviors. Unfortunately, due to technical limitations, the specific temporal dynamics linking VTA dopamine cell activation and ethanol self-administration are not known. In fact, establishing a causal link between specific patterns of dopamine transmission and ethanol drinking behaviors has proven elusive. Here, we sought to address these gaps in our knowledge using a newly developed viral-mediated gene delivery strategy to selectively express Channelrhodopsin-2 (ChR2) on dopamine cells in the VTA of wild-type rats. We then used this approach to precisely control VTA dopamine transmission during voluntary ethanol drinking sessions. The results confirmed that ChR2 was selectively expressed on VTA dopamine cells and delivery of blue light pulses to the VTA induced dopamine release in accumbal terminal fields with very high temporal and spatial precision. Brief high frequency VTA stimulation induced phasic patterns of dopamine release in the nucleus accumbens. Lower frequency stimulation, applied for longer periods mimicked tonic increases in accumbal dopamine. Notably, using this optogenetic approach in rats engaged in an intermittent ethanol drinking procedure, we found that tonic, but not phasic, stimulation of VTA dopamine cells selectively attenuated ethanol drinking behaviors. Collectively, these data demonstrate the effectiveness of a novel viral targeting strategy that can be used to restrict opsin expression to dopamine cells in standard outbred animals and provide the first causal evidence demonstrating that tonic activation of VTA dopamine neurons selectively decreases ethanol self-administration behaviors.

  3. Guidelines for transient analysis in water transmission and distribution systems

    NARCIS (Netherlands)

    Pothof, I.W.M.; Karney, B.W.

    2012-01-01

    All water systems leak, and many supply systems do so considerably, with water losses typically of approximately 20% of the water production. The IWA Water Loss Task Force aims for a significant reduction of annual water losses by drafting documents to assist practitioners and others to prevent, mon

  4. Kansas Communication and Instruction System through Fiber-Optic Transmission.

    Science.gov (United States)

    Kansas State Dept. of Education, Topeka.

    Schools and communities will restructure as they move into the next decade. The success of this restructuring will be dependent upon access to and sharing of quality teaching and information through an expanded communication system. One of the major two-way interactive technologies is the fiber-optic cable: a delivery system that will provide…

  5. Analysis of Basic Transmission Networks for Integrated Ship Control Systems

    DEFF Research Database (Denmark)

    Hansen, T.N.; Granum-Jensen, M.

    1993-01-01

    Description of a computer network for Integrated Ship Control Systems which is going to be developed as part of an EC-project. Today equipment of different make are not able to communicate with each other because most often each supplier of ISC systems has got their own proprietary network.....

  6. Research of data transmission security in videoconference system

    Institute of Scientific and Technical Information of China (English)

    LIU Yan-long; WANG Chun-lei; SUN Zhi-tao

    2007-01-01

    Many coal enterprises have built the videoconference systems on their LAN(Local Area Network). As the development of these enterprises, their organizations are distributed over our country and even over the world. Therefore, the videoconference systems have to run over WAN (Wide Area Network). Normally, the structure of a videoconference system is center_division including MCU (multi control unit) and participants. No QoS and security assurance are available now because all videoconference system is based on TCP/IP. Therefore, the system stability is absolutely depended on the Network.This paper discussed how to anti ARP attacking. The method discussed in this paper is based on TCP/IP.

  7. Nonlinear phase noise in coherent optical OFDM transmission systems.

    Science.gov (United States)

    Zhu, Xianming; Kumar, Shiva

    2010-03-29

    We derive an analytical formula to estimate the variance of nonlinear phase noise caused by the interaction of amplified spontaneous emission (ASE) noise with fiber nonlinearity such as self-phase modulation (SPM), cross-phase modulation (XPM), and four-wave mixing (FWM) in coherent orthogonal frequency division multiplexing (OFDM) systems. The analytical results agree very well with numerical simulations, enabling the study of the nonlinear penalties in long-haul coherent OFDM systems without extensive numerical simulation. Our results show that the nonlinear phase noise induced by FWM is significantly larger than that induced by SPM and XPM, which is in contrast to traditional WDM systems where ASE-FWM interaction is negligible in quasi-linear systems. We also found that fiber chromatic dispersion can reduce the nonlinear phase noise. The variance of the total phase noise increases linearly with the bit rate, and does not depend significantly on the number of subcarriers for systems with moderate fiber chromatic dispersion.

  8. Nurses' Attitudes Toward the Use of the Bar-coding Medication Administration System

    NARCIS (Netherlands)

    S.D. Marini; A. Hasman; H.A.S. Huijer; H. Dimassi

    2010-01-01

    This study determines nurses' attitudes toward bar-coding medication administration system use. Some of the factors underlying the successful use of bar-coding medication administration systems that are viewed as a connotative indicator of users' attitudes were used to gather data that describe the

  9. Fatigue Prediction of a Gear Transmission System based on Vibro-Acoustic Measurements

    OpenAIRE

    Ahmaida, Anwar; Zhen, Dong; Gu, Fengshou.; Ball, Andrew

    2013-01-01

    Gearing components play a pivotal role in most power transmission mechanisms but their application in industry consistently results in significant disruption and losses due to gear failures. This emphasises the significance of condition monitoring and fault diagnostics techniques of gear transmission systems to enhance overall safety and operational reliability in order to minimise gearbox failure rates and their associated disruption and losses to industry. In a wide range of industrial cont...

  10. Reprint of “Performance analysis of a model-sized superconducting DC transmission system based VSC-HVDC transmission technologies using RTDS”

    Science.gov (United States)

    Dinh, Minh-Chau; Ju, Chang-Hyeon; Kim, Sung-Kyu; Kim, Jin-Geun; Park, Minwon; Yu, In-Keun

    2013-01-01

    The combination of a high temperature superconducting DC power cable and a voltage source converter based HVDC (VSC-HVDC) creates a new option for transmitting power with multiple collection and distribution points for long distance and bulk power transmissions. It offers some greater advantages compared with HVAC or conventional HVDC transmission systems, and it is well suited for the grid integration of renewable energy sources in existing distribution or transmission systems. For this reason, a superconducting DC transmission system based HVDC transmission technologies is planned to be set up in the Jeju power system, Korea. Before applying this system to a real power system on Jeju Island, system analysis should be performed through a real time test. In this paper, a model-sized superconducting VSC-HVDC system, which consists of a small model-sized VSC-HVDC connected to a 2 m YBCO HTS DC model cable, is implemented. The authors have performed the real-time simulation method that incorporates the model-sized superconducting VSC-HVDC system into the simulated Jeju power system using Real Time Digital Simulator (RTDS). The performance analysis of the superconducting VSC-HVDC systems has been verified by the proposed test platform and the results were discussed in detail.

  11. Automatic Voltage Control (AVC) of Danish Transmission System - Concept design

    DEFF Research Database (Denmark)

    Qin, Nan; Abildgaard, Hans; Lund, P.

    2014-01-01

    , objectives, constraints, algorithms for optimal power flow and some special functions in particular systems, which inspires the concept design of a Danish AVC system to address the future challenges of voltage control. In the concept, the Danish AVC design is based on a centralized control scheme. All...... the buses are monitored where the voltage magnitudes are maintained continually. The loss minimization including switching cost is the objectives of the AVC system. The reactive power reserves as constraints are taken into account to limit the regulation capabilities of generators. The Day ahead and short...

  12. Analytical investigation of the pericyclic variable-speed transmission system for helicopter main-gearbox

    Science.gov (United States)

    Saribay, Zihni Burcay

    In the recent years, there has been significant interest in the new developments and improvements of the rotorcraft transmission systems. The main goal of the rotorcraft transmission research is the reduction of overall gear train weight while maintaining the efficiency and reliability. The Pericyclic Variable-Speed Transmission (PVT) System is one of the potential candidates of the future rotorcraft drive trains to achieve these goals. Hence, this thesis explores the feasibility of the Pericyclic Variable Speed Transmission (PVT) for rotorcraft transmissions. The contributions of this research are grouped in two main categories. These two categories are in the component level and in the system level. These contributions are originated from the analysis of the Pericyclic Variable Speed (PVT) System. In the component level, a new concept of face-gear meshing is presented first time in the gear research field. The meshing of a face-gear with another face-gear is presented at high shaft angles as an alternative to bevel gears. The conjugacy of this new face-gear meshing concept is formulated and demonstrated. The geometry, unloaded mesh kinematics and loaded mesh kinematics of the conjugate meshing face-gear pair is analyzed. The physics behind the meshing face-gear teeth contact is revealed using theory of gearing, differentiable geometry and elastohydrodynamic lubrication theory. The existence of the lubricant film formation between the meshing teeth is demonstrated. The behavior of the sliding friction coefficient is analytically simulated through the meshing cycle. In the system level contributions, the Pericyclic Variable Speed (PVT) Transmission is presented as a new unique innovative gear train mechanism. The speed change capability is analyzed for rotorcraft demands. The power flow behavior is explored for its use in variable speed transmission systems. The established component level contributions are evaluated with the PVT at the system level. The efficiency

  13. Bio-Authentication based Secure Transmission System using Steganography

    CERN Document Server

    Zehra, Najme; Ahuja, Somya; Bansal, Shubha

    2010-01-01

    Biometrics deals with identity verification of an individual by using certain physiological or behavioral features associated with a person. Biometric identification systems using fingerprints patterns are called AFIS (Automatic Fingerprint Identification System). In this paper a composite method for Fingerprint recognition is considered using a combination of Fast Fourier Transform (FFT) and Sobel Filters for improvement of a poor quality fingerprint image. Steganography hides messages inside other messages in such a way that an "adversary" would not even know a secret message were present. The objective of our paper is to make a bio-secure system. In this paper bio-authentication has been implemented in terms of finger print recognition and the second part of the paper is an interactive steganographic system hides the user's data by two options- creating a songs list or hiding the data in an image.

  14. Investigation of EDFA Performance in 8 Channel WDM Transmission System

    OpenAIRE

    Lavrinoviča, I; Poriņš, J

    2015-01-01

    Erbium Doped Fiber Amplifier (EDFA) obtained a wide range of applications in research and commercial applications in optical fiber communication systems. It has been considered as an attractive solution because of several major advantages - low loss optical window of silica based fiber (1525-1565 nm), high energy efficiency (>50 %) and time constant enough to cover modulation noises. However, the presence of amplified spontaneous emission (ASE), the difficulty in implementing a WDM system - t...

  15. Impact of Utility-Scale Distributed Wind on Transmission-Level System Operations

    Energy Technology Data Exchange (ETDEWEB)

    Brancucci Martinez-Anido, C.; Hodge, B. M.

    2014-09-01

    This report presents a new renewable integration study that aims to assess the potential for adding distributed wind to the current power system with minimal or no upgrades to the distribution or transmission electricity systems. It investigates the impacts of integrating large amounts of utility-scale distributed wind power on bulk system operations by performing a case study on the power system of the Independent System Operator-New England (ISO-NE).

  16. Investigate the Performance of LG 00 Mode in Cost Effective Hybrid Radio over Multimode Transmission System

    Directory of Open Access Journals (Sweden)

    Pardeep Kaur

    2014-05-01

    Full Text Available Radio over fiber (RoF technology composed for apprehension of future high performance integrated networks and future broadband networks. Multimode fiber links can offer a convenient approach for low cost and short Radio over Fiber (RoF systems. This work is based on the cost effective radio over multimode transmission system (Ro-MMF for long reach transmission. Error free transmission of 10 Gbps data with 10 GHz radio signal over multimode fiber link successfully demonstrated over 40 km. furthermore, The results are represented for Ro-MMF system by using LG (Laguerre-Gaussian 00 mode. The Performance of LG 00 mode in terms of SNR and Eye diagram investigated in proposed system.

  17. Harmonics in Offshore Wind Power Plants Employing Power Electronic Devices in the Transmission System

    DEFF Research Database (Denmark)

    Glasdam, Jakob Bærholm

    of wind power. The onshore as well as offshore wind power plants (OWPPs) therefore have to meet the same stringent requirement as the conventional power plants. This can be accommodated by employment of flexible alternating current transmission system (FACTS) devices, such as the static compensator...... gives rise to a number of challenges to the wind power industry with regard to construction, installation as well as transmission of the generated energy. The STATCOM and the voltage-sourced converter high-voltage direct current (VSC-HVDC) are attractive solutions for grid connection of remotely located...... OWPPs. The new system configuration requires in-depth knowledge of all relevant technical aspects, including e.g. the involved control systems performance and robustness for all possible operating conditions. The transmission system operator might impose new control requirements when the VSC...

  18. Nonlinear phase noise mitigation in phase-sensitive amplified transmission systems.

    Science.gov (United States)

    Olsson, Samuel L I; Karlsson, Magnus; Andrekson, Peter A

    2015-05-04

    We investigate the impact of in-line amplifier noise in transmission systems amplified by two-mode phase-sensitive amplifiers (PSAs) and present the first experimental demonstration of nonlinear phase noise (NLPN) mitigation in a modulation format independent PSA-amplified transmission system. The NLPN mitigation capability is attributed to the correlated noise on the signal and idler waves at the input of the transmission span. We study a single-span system with noise loading in the transmitter but the results are expected to be applicable also in multi-span systems. The experimental investigation is supported by numerical simulations showing excellent agreement with the experiments. In addition to demonstrating NLPN mitigation we also present a record high sensitivity receiver, enabled by low-noise PSA-amplification, requiring only 4.1 photons per bit to obtain a bit error ratio (BER) of 1 × 10(-3) with 10 GBd quadrature phase-shift keying (QPSK) data.

  19. Transmission Congestion and Voltage Profile Management Using TCSC and TCPAR in Deregulated Power System

    Directory of Open Access Journals (Sweden)

    K.Ragini

    2014-10-01

    Full Text Available In present days all our basic needs are relates with electricity. As the population increases, the demand for electricity is also tremendously increases. In the past, the entire electricity industry is under the control of government and also monopolized. But now, the power industry in many countries is moving rapidly from regulated conventional setup to deregulated environment. The transmission congestion is one of the technical problems that particularly appear in the deregulated power system. If congestion is not managed we face the problems of electricity price improvement and security and stability problems. Congestion relief can be handled using FACTS device such as TCSC, TCPAR where transmission capability will be improved. These FACTS devices are optimally placed on transmission system using Sensitivity approach method. The proposed method is carried out on Modified IEEE-14 bus system and IEEE-24 bus system Using Power World Simulator17 software.

  20. Design of aircraft turbine fan drive gear transmission system

    Science.gov (United States)

    Dent, E.; Hirsch, R. A.; Peterson, V. W.

    1970-01-01

    The following basic types of gear reduction concepts were studied as being feasible power train systems for a low-bypass-ratio, single-spool, geared turbofan engine for general aircraft use: (1) single-stage external-internal reduction, (2) gears (offset shafting), (3) multiple compound idler gear system (concentric shafting), and (4) star gear planetary system with internal ring gear final output member (concentric shafting-counterrotation). In addition, studies were made of taking the accessories drive power off both the high-speed and low-speed shafting, using either face gears or spiral bevel gears. Both antifriction and sleeve-type bearings were considered for the external-internal and star-planet reduction concepts.

  1. Word width reduction system for videosignal processing and transmission

    NARCIS (Netherlands)

    Coenen, A.J.

    1991-01-01

    Abstract of WO 9104611 (A1) System for converting a PCM input signal with uniform noise spectrum, comprising a series of digital words each of K-bits appearing with a predetermined repetition frequency, into a PCM output signal with a non-uniform noise spectrum comprising a series of digital wor

  2. Phase-modulation transmission system for quantum cryptography.

    Science.gov (United States)

    Mérolla, J M; Mazurenko, Y; Goedgebuer, J P; Porte, H; Rhodes, W T

    1999-01-15

    We describe a new method for quantum key distribution that utilizes phase modulation of sidebands of modulation by use of integrated electro-optic modulators at the transmitting and receiving modules. The system is shown to produce constructive or destructive interference with unity visibility, which should allow quantum cryptography to be carried out with high flexibility by use of conventional devices.

  3. Absence of frequent herpesvirus transmission in a nonhuman primate predator-prey system in the wild.

    Science.gov (United States)

    Murthy, Sripriya; Couacy-Hymann, Emmanuel; Metzger, Sonja; Nowak, Kathrin; De Nys, Helene; Boesch, Christophe; Wittig, Roman; Jarvis, Michael A; Leendertz, Fabian H; Ehlers, Bernhard

    2013-10-01

    Emergence of viruses into the human population by transmission from nonhuman primates (NHPs) represents a serious potential threat to human health that is primarily associated with the increased bushmeat trade. Transmission of RNA viruses across primate species appears to be relatively frequent. In contrast, DNA viruses appear to be largely host specific, suggesting low transmission potential. Herein, we use a primate predator-prey system to study the risk of herpesvirus transmission between different primate species in the wild. The system was comprised of western chimpanzees (Pan troglodytes verus) and their primary (western red colobus, Piliocolobus badius badius) and secondary (black-and-white colobus, Colobus polykomos) prey monkey species. NHP species were frequently observed to be coinfected with multiple beta- and gammaherpesviruses (including new cytomegalo- and rhadinoviruses). However, despite frequent exposure of chimpanzees to blood, organs, and bones of their herpesvirus-infected monkey prey, there was no evidence for cross-species herpesvirus transmission. These findings suggest that interspecies transmission of NHP beta- and gammaherpesviruses is, at most, a rare event in the wild.

  4. Experiment on 60-GHz MMW transmission performance in an optical fiber and wireless system

    Institute of Scientific and Technical Information of China (English)

    Qi Tang; Lin Chen; Jiangnan Xiao; Zizheng Cao

    2011-01-01

    We experimentally investigate the transmission performance of 60-GHz signals over standard single-mode fiber (SSMF) and wireless links at different bit rates.Experimental results show that in a transmission of over 10-km SSMF and 1.3-m wireless link, bit rate reaches up to 5 Gb/s and bit error rate (BER) is leas than 10-4.The main limiting factor in such radio-over-fiber (ROF) systems is intersymbol interferences caused by the so-called walk-off effect when BER is below 10-8.In addition, a transmission of over 20-km SSMF without chromatic dispersion compensation is briefly investigated.For a BER of 10-8, the optical penalty is 2 dB.%@@ We experimentally investigate the transmission performance of 60-GHz signals over standard single-mode fiber (SSMF) and wireless links at different bit rates.Experimental results show that in a transmission of over 10-km SSMF and 1.3-m wireless link, bit rate reaches up to 5 Gb/s and bit error rate (BER) is less than 10-4.The main limiting factor in such radio-over-fiber (ROF) systems is intersymbol interferences caused by the so-called walk-off effect when BER is below 10-8.In addition, a transmission of over 20-km SSMF without chromatic dispersion compensation is briefly investigated.For a BER of 10-s, the optical penalty is 2 dB.

  5. Federal Emergency Management Information System (FEMIS) System Administration Guide for FEMIS Version 1.4.6

    Energy Technology Data Exchange (ETDEWEB)

    Arp, J.A.; Bower, J.C.; Burnett, R.A.; Carter, R.J.; Downing, T.R.; Fangman, P.M.; Gerhardstein, L.H.; Homer, B.J.; Johnson, D.M.; Johnson, R.L.; Johnson, S.M.; Loveall, R.M.; Martin, T.J.; Millard, W.D.; Schulze, S.A.; Stoops, L.R.; Tzemos, S.; Wood, B.M.

    1999-06-29

    The Federal Emergency Management Information System (FEMIS) is an emergency management planning and response tool that was developed by the Pacific Northwest National Laboratory (PNNL) under the direction of the U.S. Army Chemical Biological Defense Command. The FEMIS System Administration Guide provides information necessary for the system administrator to maintain the FEMIS system. The FEMIS system is designed for a single Chemical Stockpile Emergency Preparedness Program (CSEPP) site that has multiple Emergency Operations Centers (EOCs). Each EOC has personal computers (PCs) that emergency planners and operations personnel use to do their jobs. These PCs are corrected via a local area network (LAN) to servers that provide EOC-wide services. Each EOC is interconnected to other EOCs via a Wide Area Network (WAN). Thus, FEMIS is an integrated software product that resides on client/server computer architecture. The main body of FEMIS software, referred to as the FEMIS Application Software, resides on the PC client(s) and is directly accessible to emergency management personnel. The remainder of the FEMIS software, referred to as the FEMIS Support Software, resides on the UNIX server. The Support Software provides the communication data distribution and notification functionality necessary to operate FEMIS in a networked, client/server environment.

  6. Grid connection of active stall wind farms using a VSC based DC transmission system

    DEFF Research Database (Denmark)

    Iov, Florin; Sorensen, Paul; Hansen, Anca-Daniela;

    2005-01-01

    are fulfilled. However, the traditional squirrel-cage generators based wind turbines/wind farms directly connected to the grid have less control capabilities. These wind turbines/farms cannot regulate their production and contribute to power system stability. A DC transmission system for connection...

  7. A new inductive sensor for online health monitoring of mechanical transmission systems

    DEFF Research Database (Denmark)

    Wang, Chao; Liu, Xiao; Chen, Zhe

    2015-01-01

    Metal debris in lubricating oil contains abundant information regarding the ageing and wear of mechanical transmission systems. The health condition of the lubricated systems can be indicated by the quantity and size of the metal particles, which may provide very early warnings of faults/ failure...

  8. Probe Improvement of Inductive Sensor for Online Health Monitoring of Mechanical Transmission Systems

    DEFF Research Database (Denmark)

    Wang, Chao; Liu, Xiao; Chen, Zhe

    2015-01-01

    Metal debris in lubricating oil contains abundant information regarding the ageing and wear/damage of mechanical transmission systems. The health condition of the lubricated systems can be indicated by the concentration and size of the metal abrasive particles, which may provide very early warnin...

  9. Insulator and Clerance Requirements in Overhead Line Transmission Systems without Shield Wires

    DEFF Research Database (Denmark)

    Sørensen, Thomas Kjærsgaard; Holbøll, Joachim

    2008-01-01

    This paper theoretically examines the required insulation lengths and clearances in 400 kV overhead line systems when not making use of ground wires as lightning protection. The influence of lightning strikes to the system is investigated based on dynamic transmission line simulations of a 400 kV...

  10. The development of a system to guide volatile anaesthetic administration.

    Science.gov (United States)

    Kennedy, R R; French, R A

    2011-03-01

    We have developed and deployed within our operating rooms a system which provides real-time estimates of effect-site levels of inhalational anaesthetic agents along with forward predictions of end-tidal and effect-site concentrations. The initial aim of this project was to provide users of inhalational agents with tools similar to those available in target-controlled infusion systems. This paper describes the development and implementation of the system and outlines evaluation and uses of the system. The prototype was developed by combining a locally developed data logging and trend display system with a model of uptake developed as a teaching tool in 1982. This uptake model performs as well as contemporary models of propofol uptake and distribution. Following initial evaluation, the system has been deployed in over half our operating rooms and uses data gathered from the Datex/GE Anaesthesia Delivery Unit anaesthetic machines. We have conducted a number of studies of the system itself explored aspects of the underlying models, and used the system to investigate effect-site guided anesthesia and as a tool for data collection in other studies. The system has been well accepted locally and has been shown to facilitate faster changes in inhalational levels. We have also seen a significant decrease in fresh gas flow rates over recent years and attribute this in part to the predictive system, which simplifies the task of determining the appropriate combination of gas flow and vapour dial setting. The system also provides a useful platform for a range of research projects.

  11. Frequency Transmission Control of Local Networked Control Systems Approach

    Directory of Open Access Journals (Sweden)

    O. Esquivel-Flores

    2012-08-01

    Full Text Available The use of Network Control Systems has been successful in the industry and therefore has opened several lines ofresearch. Control systems over a communication network include two important considerations, control andscheduling. Co-design strategies are focused on maintaining adequate control performance and maximize the level ofservice. Network scheduling is the main objective to resolve because through a balanced data load is possible tomaintain control performance in a desired level. This article reviews a scheduling strategy based on frequencytransition modeled as a linear subsystem, this control reconfigure on line the sensors’ periods. The case of study isthe control of a prototype helicopter and by numerical simulations it shows the effect of changing the transmissionfrequency.

  12. Portable light transmission measuring system for preserved corneas

    Science.gov (United States)

    Ventura, Liliane; de Jesus, Gabriel Torres; de Oliveira, Gunter Camilo Dablas; Sousa, Sidney JF

    2005-01-01

    Background The authors have developed a small portable device for the objective measurement of the transparency of corneas stored in preservative medium, for use by eye banks in evaluation prior to transplantation. Methods The optical system consists of a white light, lenses, and pinholes that collimate the white light beams and illuminate the cornea in its preservative medium, and an optical filter (400–700 nm) that selects the range of the wavelength of interest. A sensor detects the light that passes through the cornea, and the average corneal transparency is displayed. In order to obtain only the tissue transparency, an electronic circuit was built to detect a baseline input of the preservative medium prior to the measurement of corneal transparency. The operation of the system involves three steps: adjusting the "0 %" transmittance of the instrument, determining the "100 %" transmittance of the system, and finally measuring the transparency of the preserved cornea inside the storage medium. Results Fifty selected corneas were evaluated. Each cornea was submitted to three evaluation methods: subjective classification of transparency through a slit lamp, quantification of the transmittance of light using a corneal spectrophotometer previously developed, and measurement of transparency with the portable device. Conclusion By comparing the three methods and using the expertise of eye bank trained personnel, a table for quantifying corneal transparency with the new device has been developed. The correlation factor between the corneal spectrophotometer and the new device is 0,99813, leading to a system that is able to standardize transparency measurements of preserved corneas, which is currently done subjectively. PMID:16372912

  13. A full-duplex CATV/wireless-over-fiber lightwave transmission system.

    Science.gov (United States)

    Li, Chung-Yi; Lu, Hai-Han; Ying, Cheng-Ling; Cheng, Chun-Jen; Lin, Che-Yu; Wan, Zhi-Wei; Chen, Jian-Hua

    2015-04-06

    A full-duplex CATV/wireless-over-fiber lightwave transmission system consisting of one broadband light source (BLS), two optical interleavers (ILs), one intensity modulator, and one phase modulator is proposed and experimentally demonstrated. The downstream light is optically promoted from 10Gbps/25GHz microwave (MW) data signal to 10Gbps/100GHz and 10Gbps/50GHz millimeter-wave (MMW) data signals in fiber-wireless convergence, and intensity-modulated with 50-550 MHz CATV signal. For up-link transmission, the downstream light is phase-remodulated with 10Gbps/25GHz MW data signal in fiber-wireless convergence. Over a 40-km single-mode fiber (SMF) and a 10-m radio frequency (RF) wireless transport, bit error rate (BER), carrier-to-noise ratio (CNR), composite second-order (CSO), and composite triple-beat (CTB) are observed to perform well in such full-duplex CATV/wireless-over-fiber lightwave transmission systems. This full-duplex 100-GHz/50-GHz/25-GHz/550-MHz lightwave transmission system is an attractive alternative. This transmission system not only presents its advancement in the integration of fiber backbone and CATV/wireless feeder networks, but also it provides the advantages of a communication channel for higher data rates and bandwidth.

  14. Transmission stability and Raman-induced amplitude dynamics in multichannel soliton-based optical waveguide systems

    Science.gov (United States)

    Peleg, Avner; Nguyen, Quan M.; Tran, Thinh P.

    2016-12-01

    We study transmission stability and dynamics of pulse amplitudes in N-channel soliton-based optical waveguide systems, taking into account second-order dispersion, Kerr nonlinearity, delayed Raman response, and frequency dependent linear gain-loss. We carry out numerical simulations with systems of N coupled nonlinear Schrödinger (NLS) equations and compare the results with the predictions of a simplified predator-prey model for Raman-induced amplitude dynamics. Coupled-NLS simulations for single-fiber transmission with 2 ≤ N ≤ 4 frequency channels show stable oscillatory dynamics of soliton amplitudes at short-to-intermediate distances, in excellent agreement with the predator-prey model's predictions. However, at larger distances, we observe transmission destabilization due to resonant formation of radiative sidebands, which is caused by Kerr nonlinearity. The presence of linear gain-loss in a single fiber leads to a limited increase in transmission stability. Significantly stronger enhancement of transmission stability is achieved in a nonlinear N-waveguide coupler due to efficient suppression of radiative sideband generation by the linear gain-loss. As a result, the distances along which stable Raman-induced dynamics of soliton amplitudes is observed are significantly larger in the waveguide coupler system compared with the single-fiber system.

  15. Power line maintenance information system using low-power radio data transmission. Shodenryoku musen denso wo riyoshita sodensen hoshu joho system

    Energy Technology Data Exchange (ETDEWEB)

    Kanemaru, K.; Matsubara, R.; Kaito, J.; Toyota, S. (Hitachi Cable, Ltd., Tokyo (Japan))

    1994-05-20

    Currently in the major power transmission line, a composite fiber optic overhead ground wire (OPGW) is installed, and it is being made the best use as an information transmission line. When the various maintenance informations on the transmission lines can be collected and transmitted by utilizing this OPGW, there will be the benefits that an effective system for the maintenance work of the transmission lines can be constructed, the informations, which could not be obtained by a conventional patrol and tour inspection so far, could be all the time acquired highly accurately and more rapidly. In this report by considering a use of the radio transmission together with OPGW transmission, in order to solve the constraints on an information transmission in a power transmission line maintenance system by utilizing OPGW, the concrete radio transmission systems were proposed about each of interpolation method of the sensor signal transmission method and the OPGW data transmission system. Especially as for the sensor signal system, it was shown that, as a result of the quantitative investigation of a transmission efficiency taking account of the hidden terminal problems, an interpolating data transmission system through a low-power radio combined the slotted transmission timing with the carrier sensed multiple access (CSMA) system was superior. 8 refs., 7 figs., 6 tabs.

  16. A Case Study Of Turkish Transmission System For VoltageDips

    DEFF Research Database (Denmark)

    Inan, E.; Alboyaci, B.; Bak, Claus Leth

    2009-01-01

    Power quality problems usually appear in the form of voltage sags, transients and harmonics. From these three broad categories of power quality problems, voltage dips account the most disturbances experienced by industrial customers. Voltage dips generally refer to instantaneous short...... analysis of voltage dip performance of the whole transmission system, is used to compare with results constructed fault statics from SIMPOW DIPS analysis program real data. SIMPOW DIPS software enables to calculate dip frequency for all busses and lines.......-duration voltage variations. The aim of this paper is to have an idea about voltage dip performance of Turkey Transmission System. Turkey's transmission system has 21 regions. For simulations, 2nd region, which includes Istanbul city's area is heavy loaded, is selected. For purposes of early warning and later...

  17. Reliability worth applied to transmission expansion planning based on ant colony system

    Energy Technology Data Exchange (ETDEWEB)

    Leite da Silva, Armando M.; Rezende, Leandro S. [Institute of Electric Systems and Energy, Federal University of Itajuba, UNIFEI (Brazil); da Fonseca Manso, Luiz A.; de Resende, Leonidas C. [Department of Electrical Engineering, Federal University of Sao Joao del Rei, UFSJ (Brazil)

    2010-12-15

    This paper proposes a new methodology to solve transmission expansion planning (TEP) problems in power system, based on the metaheuristic ant colony optimisation (ACO). The TEP problem includes the search for the least cost solution, bearing in mind investment cost and reliability worth. Reliability worth is considered through the assessment of the interruption costs represented by the index LOLC - loss of load cost. The focus of this work is the development of a tool for the multi-stage planning of transmission systems and how reliability aspects can influence on the decision-making process. The applications of the proposed methodology are illustrated through case studies carried out using a test system and a real sub-transmission network. (author)

  18. ATLAS TDAQ System Administration: an overview and evolution

    CERN Document Server

    LEE, CJ; The ATLAS collaboration; BOGDANCHIKOV, A; BRASOLIN, F; CONTESCU, AC; DARLEA, GL; KOROL, A; SCANNICCHIO, DA; TWOMEY, M; VALSAN, ML

    2013-01-01

    The ATLAS Trigger and Data Acquisition (TDAQ) system is responsible for the online processing of live data streaming from the ATLAS experiment at the Large Hadron Collider (LHC) at CERN. The system processes the direct data readout from ~100 million channels on the detector through three trigger levels, selecting interesting events for analysis with a factor of 10^7 reduction on the data rate with a latency of less than a few seconds. Most of the functionality is implemented on ~3000 servers composing the online farm. Due to the critical functionality of the system a sophisticated computing environment is maintained, covering the online farm and ATLAS control rooms, as well as a number of development and testing labs. The specificity of the system required the development of dedicated applications (e.g. ConfDB, BWM) for system configuration and maintenance; in parallel other Open Source tools (Puppet and Quattor) are used to centrally configure the operating systems. The health monitoring of the TDAQ system h...

  19. HVDC transmission power conversion applications in power systems

    CERN Document Server

    Kim, Chan-Ki; Jang, Gil-Soo; Lim, Seong-Joo; Lee, Seok-Jin

    2009-01-01

    HVDC is a critical solution to several major problems encountered when trying to maintain systemic links and quality in large-scale renewable energy environments. HDVC can resolve a number of issues, including voltage stability of AC power networks, reducing fault current, and optimal management of electric power, ensuring the technology will play an increasingly important role in the electric power industry. To address the pressing need for an up-to-date and comprehensive treatment of the subject, Kim, Sood, Jang, Lim and Lee have collaborated to produce this key text and reference.  Combin

  20. Under Water Wireless Control Using Zigbee For Transmissions Systems

    Directory of Open Access Journals (Sweden)

    Sreenivsa Reddy P,

    2014-07-01

    Full Text Available The aim of this project is to develop under water communication system using the zigbee protocol stack. A robot can be defined as a programmable, self-controlled device consisting of electronic, electrical, or mechanical units. An industrial robot is officially defined by as an automatically controlled, reprogrammable, multipurpose, manipulator, programmable in three or more axes. Robots are especially desirable for certain work functions because, unlike humans, they never get tired. They can endure physical conditions that are uncomfortable or even dangerous; they can operate in airless conditions.

  1. Professional performance evaluation within the Romanian administrative system

    Directory of Open Access Journals (Sweden)

    Cristina MANOLE

    2010-12-01

    Full Text Available The current economic crisis, manifested in the entire world, highlights the need for sustained involvement of the local and regional authorities in each country, in conceiving and implementing Community policies (which already exist at European level having an essential role in implementing the economic plans achievement. This view was shared by all European Union Member States, of which Romania is part, since 2007. Therefore, the economic crisis which is reflected in the Romanian society today, requires prompt and sustained intervention by the authorities in the execution of the economic recovery plan, implying the community strategies, due to sharply budgetary expenses cut, which is found in all European countries. In order to achieve this major objective, the Romanian authorities should have qualified and properly motivated personnel through an adequate remuneration, according to the training, skills, responsibilities and especially individual performance obtained at each position, as it happens in most developed countries of the European Union. In this context, this study approaches the issues related to the performance evaluation of the public sector’s employees. Considering the fact that strengthening and developing the human resources segment is a strategic goal of the Romanian administration for the period 2008 - 2013, which will lead to modernizing it and making it more efficient (at both central and local level, the personnel performance evaluation, at the organizational level represents a fundamental activity from the human resources’ management perspective.

  2. Transient Stability of the Power System with the Exact Long Transmission Line Model

    Directory of Open Access Journals (Sweden)

    Prechanon Kumkratug

    2012-01-01

    Full Text Available Problem statement: The exact long transmission line model consists of the lump of the series resistance, reactance and shunt capacitance. With the consideration the actual long transmission line model, it causes in the difficulty of deriving the mathematical model. Approach: This study investigates the transient stability of power system with consideration the exact long transmission line model. The concept of two-port network is applied in this study. The generator, transformer and short transmission line are represented by two-port networks. With the combination principles of the series and shunt connection, the mathematical model is achieved in a much simpler way. The proposed method is tested on the sample system and compared on various cases. Results: The first swing of rotor angle curve of the faulted system without the resistance is obviously higher than that of with the resistance whereas the second swing of the faulted system without the resistance is slightly less than that of with the resistance. The critical clearing time of the system with the resistance is better than that of with resistance. Conclusion: It was found from the simulation results that the resistance of the line provides the improvement of the first swing but not for the second swing. It was found from this study that for practical long line, the resistance is very import parameters to determine the critical clearing time of the single machine infinite system whereas shunt capacitance insignificantly affects on the critical clearing time of the single machine infinite bus system.

  3. GPS-Like Phasing Control of the Space Solar Power System Transmission Array

    Science.gov (United States)

    Psiaki, Mark L.

    2003-01-01

    The problem of phasing of the Space Solar Power System's transmission array has been addressed by developing a GPS-like radio navigation system. The goal of this system is to provide power transmission phasing control for each node of the array that causes the power signals to add constructively at the ground reception station. The phasing control system operates in a distributed manner, which makes it practical to implement. A leader node and two radio navigation beacons are used to control the power transmission phasing of multiple follower nodes. The necessary one-way communications to the follower nodes are implemented using the RF beacon signals. The phasing control system uses differential carrier phase relative navigation/timing techniques. A special feature of the system is an integer ambiguity resolution procedure that periodically resolves carrier phase cycle count ambiguities via encoding of pseudo-random number codes on the power transmission signals. The system is capable of achieving phasing accuracies on the order of 3 mm down to 0.4 mm depending on whether the radio navigation beacons operate in the L or C bands.

  4. Adequacy assessment of composite generation and transmission systems incorporating wind energy conversion systems

    Science.gov (United States)

    Gao, Yi

    The development and utilization of wind energy for satisfying electrical demand has received considerable attention in recent years due to its tremendous environmental, social and economic benefits, together with public support and government incentives. Electric power generation from wind energy behaves quite differently from that of conventional sources. The fundamentally different operating characteristics of wind energy facilities therefore affect power system reliability in a different manner than those of conventional systems. The reliability impact of such a highly variable energy source is an important aspect that must be assessed when the wind power penetration is significant. The focus of the research described in this thesis is on the utilization of state sampling Monte Carlo simulation in wind integrated bulk electric system reliability analysis and the application of these concepts in system planning and decision making. Load forecast uncertainty is an important factor in long range planning and system development. This thesis describes two approximate approaches developed to reduce the number of steps in a load duration curve which includes load forecast uncertainty, and to provide reasonably accurate generating and bulk system reliability index predictions. The developed approaches are illustrated by application to two composite test systems. A method of generating correlated random numbers with uniform distributions and a specified correlation coefficient in the state sampling method is proposed and used to conduct adequacy assessment in generating systems and in bulk electric systems containing correlated wind farms in this thesis. The studies described show that it is possible to use the state sampling Monte Carlo simulation technique to quantitatively assess the reliability implications associated with adding wind power to a composite generation and transmission system including the effects of multiple correlated wind sites. This is an important

  5. Enhanced analgesic effect of morphine-nimodipine combination after intraspinal administration as compared to systemic administration in mice

    Indian Academy of Sciences (India)

    Dilip Verma; Subrata Basu Ray; Ishan Patro; Shashi Wadhwa

    2005-09-01

    Calcium plays an important role in the pathophysiology of pain. A number of studies have investigated the effect of L-type calcium channel blockers on the analgesic response of morphine. However, the results are conflicting. In the present study, the antinociceptive effect of morphine (2.5 g) and nimodipine (1 g) co-administered intraspinally in mice was observed using the tail flick test. It was compared to the analgesic effect of these drugs (morphine – 250 g subcutaneously; nimodipine – 100 g intraperitoneally) after systemic administration. Nimodipine is highly lipophilic and readily crosses the blood brain barrier. Addition of nimodipine to morphine potentiated the analgesic response of the latter when administered through the intraspinal route but not when administered through systemic route. It may be due to direct inhibitory effect of morphine and nimodipine on neurons of superficial laminae of the spinal cord after binding to -opioid receptors and L-type calcium channels respectively.

  6. Library Systems: FY 2012 Public Libraries Survey (Administrative Entity)

    Data.gov (United States)

    Institute of Museum and Library Services — Find key information on library systems around the United States.These data include imputed values for libraries that did not submit information in the FY 2012 data...

  7. Library Systems: FY 2013 Public Libraries Survey (Administrative Entity)

    Data.gov (United States)

    Institute of Museum and Library Services — Find key information on library systems around the United States.These data include imputed values for libraries that did not submit information in the FY 2013 data...

  8. Library Systems: FY 2014 Public Libraries Survey (Administrative Entity Data)

    Data.gov (United States)

    Institute of Museum and Library Services — Find key information on library systems around the United States.These data include imputed values for libraries that did not submit information in the FY 2014 data...

  9. THE INFORMATIONAL SYSTEM FOR RESOURSES ADMINISTRATION IN FISH FARMS

    Directory of Open Access Journals (Sweden)

    Adrian ZUGRAVU

    2005-01-01

    Full Text Available The informational system for aquaculture activities provide a financial planning and analysis tool.The software can also be of assistance to land-based farmers who want to more thoroughly utilizetheir water resources by developing small-scale fish farm systems to provide supplementary income.Informational model has been enhanced to produce a comprehensive software package foraquaculture feasibility modeling, financial planning, sales and harvesting planning and managementinformation tools.

  10. The Design of Administrative System Based On Portable Intellectual Equipment

    Institute of Scientific and Technical Information of China (English)

    Zeng,Jianhua; Chen,Haisong; Feng,Mingfa; Liang,Zhaofeng

    2005-01-01

    Regard property management of intelligentized residential area as the application background, we introduce a kind of method for the design of a management system based on portable intelligent equipments. The system is made up of intelligent terminals and personal computers. The intelligent terminals are for data collection and data storage. They communicate with personal computers through high-speed interface. The personal computers communicate with intelligent devices and carry out data analysis and data processing with VB6.0.

  11. ATLAS TDAQ System Administration: an overview and evolution

    CERN Document Server

    LEE, CJ; The ATLAS collaboration; BOGDANCHIKOV, A; BRASOLIN, F; CONTESCU, AC; DARLEA, G-L; KOROL, A; SCANNICCHIO, DA; TWOMEY, M; VALSAN, ML

    2013-01-01

    The ATLAS Trigger and Data Acquisition (TDAQ) system is responsible for the online processing of live data streaming from the ATLAS experiment at the Large Hadron Collider (LHC) at CERN. The system processes the direct data readout from ~100 million channels on the detector through multiple trigger levels, selecting interesting events for analysis with a factor of $10^{7}$ reduction on the data rate with a latency of less than a few seconds. Most of the functionality is implemented on ~3000 servers composing the online farm. Due to the critical functionality of the system a sophisticated computing environment is maintained, covering the online farm and ATLAS control rooms, as well as a number of development and testing labs. The specificity of the system required the development of dedicated applications (e.g. ConfDB, BWM) for system configuration and maintenance; in parallel other Open Source tools (Puppet and Quattor) are used to centrally configure the operating systems. The health monitoring of the TDAQ s...

  12. Transmission of specific groups of bacteria through water distribution system.

    Science.gov (United States)

    Grabińska-Łoniewska, Anna; Wardzyńska, Grazyna; Pajor, Elzbieta; Korsak, Dorota; Boryń, Krystyna

    2007-01-01

    Microbial contamination of a water distribution system was examined. The number and the taxonomy of non-pigmented and pigmented heterotrophic bacteria (HB), number of bacteria (Pseudomonas sp., Enterococcus sp., Campylobacter sp., Yersinia sp., representatives of the Enterobacteriaceae, coagulase-positive staphylococci, and C. pefringens) in the bulk water phase, biomass of zoogloeal aggregates of bacteria, fungi, algae, protozoa and rotifers (ZABFAPR) (separated from the above on 5 microm pore size filters) and in pipe sediments was determined. An increased number of HB occurred at the sampling sites situated as close as 4.2 km to the Water Treatment Plant (WTP), and was especially significant at 10.3 km. It was shown that the main reservoir of hygienically relevant bacteria did not occur in the water phase which is monitored in routine control analyses carried out by the WTP laboratories, but in the ZABFAPR biomass not monitored so far.

  13. Coordinated Direct and Relay Transmission with Interference Cancelation in Wireless Systems

    DEFF Research Database (Denmark)

    Thai, Chan; Popovski, Petar

    2011-01-01

    Two-way relaying schemes in wireless systems obtain throughput gain by utilizing two features (1) jointly serve two communication flows, thus implementing network coding and (2) use of information that is a priori known to cancel interference and obtain the desired signal. Based on these principles......, we propose other schemes that bring throughput gains in wireless cellular systems, where relayed and direct transmissions are carried out in coordinated way. The results show that the coordinated transmission exhibit throughput improvement similar to the two–way relaying schemes....

  14. Higher order capacity statistics of multi-hop transmission systems over Rayleigh fading channels

    KAUST Repository

    Yilmaz, Ferkan

    2012-03-01

    In this paper, we present an exact analytical expression to evaluate the higher order statistics of the channel capacity for amplify and forward (AF) multihop transmission systems operating over Rayleigh fading channels. Furthermore, we present simple and efficient closed-form expression to the higher order moments of the channel capacity of dual hop transmission system with Rayleigh fading channels. In order to analyze the behavior of the higher order capacity statistics and investigate the usefulness of the mathematical analysis, some selected numerical and simulation results are presented. Our results are found to be in perfect agreement. © 2012 IEEE.

  15. Spatiotemporal dynamics of the epidemic transmission in a predator-prey system.

    Science.gov (United States)

    Su, Min; Hui, Cang; Zhang, Yanyu; Li, Zizhen

    2008-11-01

    Epidemic transmission is one of the critical density-dependent mechanisms that affect species viability and dynamics. In a predator-prey system, epidemic transmission can strongly affect the success probability of hunting, especially for social animals. Predators, therefore, will suffer from the positive density-dependence, i.e., Allee effect, due to epidemic transmission in the population. The rate of species contacting the epidemic, especially for those endangered or invasive, has largely increased due to the habitat destruction caused by anthropogenic disturbance. Using ordinary differential equations and cellular automata, we here explored the epidemic transmission in a predator-prey system. Results show that a moderate Allee effect will destabilize the dynamics, but it is not true for the extreme Allee effect (weak or strong). The predator-prey dynamics amazingly stabilize by the extreme Allee effect. Predators suffer the most from the epidemic disease at moderate transmission probability. Counter-intuitively, habitat destruction will benefit the control of the epidemic disease. The demographic stochasticity dramatically influences the spatial distribution of the system. The spatial distribution changes from oil-bubble-like (due to local interaction) to aggregated spatially scattered points (due to local interaction and demographic stochasticity). It indicates the possibility of using human disturbance in habitat as a potential epidemic-control method in conservation.

  16. Science, Systems, and Theoretical Alternatives in Educational Administration: The Road Less Travelled

    Science.gov (United States)

    Evers, Colin W.; Lakomski, Gabriele

    2012-01-01

    Purpose: The purpose of this paper is to offer a critical reflection on ideas that have been published in the "Journal of Educational Administration" over the last 50 years that present perspectives on the nature of educational administration and its various aspects, that are alternatives to the mainstream systems-scientific view of…

  17. Systemic administration of D-penicillamine prevents the locomotor activation after intra-VTA ethanol administration in rats.

    Science.gov (United States)

    Martí-Prats, Lucía; Sánchez-Catalán, María José; Hipólito, Lucía; Orrico, Alejandro; Zornoza, Teodoro; Polache, Ana; Granero, Luis

    2010-10-11

    Although recently published studies seem to confirm the important role displayed by acetaldehyde (ACH), the main metabolite of ethanol, in the behavioral effects of ethanol, the origin of ACH is still a matter of debate. While some authors confer more importance to the central (brain metabolism) origin of ACH, others indicate that the hepatic origin could be more relevant. In this study we have addressed this topic using an experimental approach that combines local microinjections of ethanol into the ventral tegmental area (VTA) (which guarantees the brain origin of the ACH) to induce motor activation in rats together with systemic administration (i.p.) of several doses (0, 12.5, 25 and 50 mg/kg) of D-penicillamine (DP), a sequestering agent of ACH with contrasted efficiency to abolish the behavioral effects of the drug. Our results clearly show that DP prevented in a dose-dependent manner the motor activation induced by intra-VTA ethanol, being the 50 mg/kg dose the most efficient. DP per se did not affect the basal activity of the rats. In order to determine the specificity of the DP action, we also studied the effects of DP 50 mg/kg on the DAMGO-induced motor activation after the intra-VTA administration of this mu-opioid receptors agonist. DP did not significantly modify the motor activation induced by DAMGO thus confirming the specificity of the DP effects. Our results clearly suggest that the brain-derived ACH is necessary to manifest the activating effects resulting from ethanol administration.

  18. Discussion on the System of Administrative Counterpart's Right of Resistance in China

    Institute of Scientific and Technical Information of China (English)

    FENG Yuan; SHI Hong-ping

    2011-01-01

    The research value of the right of resistance in the administrative law has been highlighted gradually in recent years with the enhancement of legal awareness and the increase of administrative cases in our country.In this paper,based on the concept and characteristics of the administrative counterpart's right of resistance and the present situation of its development in our country,a conception of system of administrative counterpart's right of resistance is proposed with the use of the regulations concerning the right of resistance in other countries for reference.

  19. Clinical evaluation of target controlled infusion system for sufentanil administration

    Institute of Scientific and Technical Information of China (English)

    ZHAO Yan; ZHANG Li-ping; WU Xin-min; JIANG Jian-yu; DUAN Jing-li; HU Yong-fang; LI Min; LIU Wei; SHENG Xiao-yan; NI Cheng; XU Mao; GUO Xiang-yang

    2009-01-01

    Background Sufentanil target controlled infusion (TCI) provides stable analgesia, better hemodynamic control than a bolus injection of intravenous anesthetics, anticipated recovery and improved quality of anesthesia during perioperative period. This study evaluated the accuracy and feasibility of TCI system for sufentanil at high concentrations in Chinese surgical patients.Methods Twelve low risk adult patients undergoing elective surgery under general anesthesia were included in this study. Sufentanil was administered with a specific TCI system incorporating the population pharmacokinetic data of sufentanil previously reported, using a target effect-site concentration of sufentanil 4 or 6 ng/ml. Sufentanil TCI duration was 30 minutes. Frequent arterial blood samples were taken during and up to 24 hours after sufentanil TCI for determination of plasma sufentanil concentrations by liquid chromatography-mass spectrometry/mass spectrometry. The changes of circulatory system function during the precedure, recovery profile and adverse effects were recorded.Measured plasma sufentanil concentrations were compared with the values predicted by the TCI system. The bias (median performance error, MDPE), procision (median absolute performance error, MDAPE) and wobble (variability of performance error) of the sufentanil TCI system were determined.Results All patients had stable cardiovascular variables during induction and maintenance of anesthesia. Time to eye opening and extubation were (5.6±1.7) minutes when TCI set to 4 ng/ml and (7.2±9.3) minutes when set to 6 ng/ml.There was no episode of agitation, muscle rigidity or intraoperative awareness. The bias (MDPE), precision (MDAPE)and wobble of the sufentanil TCI system were -3.7%, 18.9% and 19.6% respectively during TCI, and the MDPE, MDAPE and wobble were -29.1%, 31.7% and 15.0% respectively after TCI (up to 8 hours).Conclusions The TCI system programmed for sufentanil at 4 or 6 ng/ml was considered acceptable for

  20. Concept design of the high voltage transmission system for the collider tunnel

    Science.gov (United States)

    Norman, L. S.

    1992-03-01

    In order to provide electrical service to the Superconducting Super Collider Laboratory (SSCL) 54-mile-circumference collider of 125 MVA at 69 kV or 155 MVA at 138 kV of distributed power, it must be demonstrated that the concept design for a high-voltage transmission system can meet the distribution requirements of the collider electrical system with its cryogenic system's large motor loads and its pulsed power technical systems. It is a practical design, safe for operating personnel and cost-effective. The normal high-voltage transmission techniques of overhead and underground around the 54-mile collider tunnel could not be applied because of technical and physical constraints, or was environmentally unacceptable. The approach taken to solve these problems is the installation of 69-kV or 138-kV exposed solid dielectric transmission cable inside the collider tunnel with the superconducting magnets, cryogenic piping, electrical medium, and low-voltage distribution systems, and electronic/instrumentation wiring systems. This mixed-use approach has never been attempted in a collider tunnel. Research into all aspects of the engineering and installation problems and consultation with transmission cable manufacturers, electrical utilities, and European entities with similar installations--such as the Channel Tunnel--demonstrate that the concept design is feasible and practical. This paper presents a history of the evolution of the concept design. Design studies are underway to determine the system configuration and voltages. Included in this report are tunnel transmission cable system considerations and evaluation of solid dielectric high-voltage cable design.

  1. Comprehensive Benefit Evaluation of the Wind-PV-ES and Transmission Hybrid Power System Consideration of System Functionality and Proportionality

    Directory of Open Access Journals (Sweden)

    Huizheng Ji

    2017-01-01

    Full Text Available In the background of decreasing fossil fuels and increasing environmental pollution, the wind-photovoltaic energy storage and transmission hybrid power system (or called the wind-PV-ES and transmission hybrid system has become a strategic choice to achieve energy sustainability. However, the comprehensive benefit evaluation of such a combined power system is in a relatively blank state in China, which will hinder the reasonable and orderly development of this station. Four parts, the technical performance, economic benefit, ecological impact and social benefit, are considered in this paper, and a multi-angle evaluation index system of the wind-PV-ES and transmission system is designed. The projection pursuit model is used to evaluated system functionality conventionally; relative entropy theory is used to evaluate the system functionality simultaneously; and a comprehensive benefit evaluation model of the technique for order preference by similar to ideal solution (TOPSIS considering both system functionality and proportionality is constructed. Finally, the national demonstration station of the wind-PV-ES-transmission system is taken as an example to testify to the practicability and validity of the evaluation index system and model.

  2. Experiences Integrating Transmission and Distribution Simulations for DERs with the Integrated Grid Modeling System (IGMS)

    Energy Technology Data Exchange (ETDEWEB)

    Palmintier, Bryan; Hale, Elaine; Hodge, Bri-Mathias; Baker, Kyri; Hansen, Timothy M.

    2016-08-11

    This paper discusses the development of, approaches for, experiences with, and some results from a large-scale, high-performance-computer-based (HPC-based) co-simulation of electric power transmission and distribution systems using the Integrated Grid Modeling System (IGMS). IGMS was developed at the National Renewable Energy Laboratory (NREL) as a novel Independent System Operator (ISO)-to-appliance scale electric power system modeling platform that combines off-the-shelf tools to simultaneously model 100s to 1000s of distribution systems in co-simulation with detailed ISO markets, transmission power flows, and AGC-level reserve deployment. Lessons learned from the co-simulation architecture development are shared, along with a case study that explores the reactive power impacts of PV inverter voltage support on the bulk power system.

  3. Coordinated multi-point transmission technique in TDD cellular mobile system

    Institute of Scientific and Technical Information of China (English)

    Sun Shaohui; Gao Qiubin; Rakesh Tamrakar; Wang Yingmin

    2011-01-01

    Coordinated multi-point transmission/reception, CoMP, technique converts the interference signal into the useful information by controlling the interfering signals among adjacent cells. Theoretically, it is a breakthrough from the traditional interference limited non-cooperative single point transmission system, improving link reliability and enhancing the data rate. CoMP is regarded as one of the most essential and effective techniques in eliminating the inter-cell interference, boosting cell edge throughput and overall system throughput. CoMP technique has obvious advantages in TDD (time division duplexing) cellular mobile system; the necessary channel state information for CoMP can be easily obtained through channel reciprocity property in TDD system. CoMP scheme in TDD system and likely problems are analyzed in this paper, and it is shown by system simulations that the significant gain can be achieved.

  4. Study on Seismic Control of Power Transmission Tower-Line Coupled System under Multicomponent Excitations

    Directory of Open Access Journals (Sweden)

    Li Tian

    2013-01-01

    Full Text Available The seismic control of power transmission tower-line coupled system subjected to multicomponent excitations is studied in this paper. The schematic of tuned mass damper is introduced, and equations of motion of a system with tuned mass damper under multi-component excitations are proposed. Three-dimensional finite tower-line system models are created based on practical engineering in studying the response of this system without and with control. The time domain analysis takes into account geometric nonlinearity due to finite deformation. The optimal design of the transmission tower-line system with tuned mass damper is obtained according to different mass ratio. The effects of wave travel, coherency loss, and different site conditions on the system without and with control are investigated, respectively.

  5. Advances in fibers and transmission line technology for long haul submarine systems

    Science.gov (United States)

    Peckham, David W.; Kim, Jinkee; Sun, Yi; Lingle, Robert L., Jr.; Levring, Ole

    2007-11-01

    The 7.1-magnitude earthquake on December 26, 2006 in the Strait of Luzon resulted in the failure of several submarine cable systems. Seven of the nine cables that pass through the strait were damaged, disrupting communications to China, Taiwan, Japan, Korea and Singapore. This recent event highlighted the dependence of international communications on submarine fiber optic transmission systems. This paper will review the evolution of optical fiber transmission line technology that has been deployed in the long haul undersea telecommunications network. It will start with a discussion of the chronological evolution of the optical fiber transmission line architecture in section one, then give more detail regarding the technology that is still being deployed today.

  6. Vibration transmission through rolling element bearings. III - Geared rotor system studies

    Science.gov (United States)

    Lim, T. C.; Singh, R.

    1991-01-01

    The bearing matrix formulations proposed by Lim and Singh (1990) are extended to analyze the overall dynamics of a geared rotor system which includes a spur gear pair, shafts, rolling-element bearings, a motor, a load, a casing, and flexible or rigid mounts. For this purpose, discrete vibration models are developed and used to predict vibration transmission through the bearings and to investigate the effects of the bearing, casing, and mount dynamics on the dynamic characteristics of the internal rotating system. Analytical predictions show that the theory is capable of predicting the bearing and mount moment transmissibilities in addition to the force transmissibilities. The predicted flexural vibrations of the casing plate are in good agreement with measurements conducted on an experimental set-up that consisted of a high-precision beam and pinion, and four identical rolling element bearings contained in a flexible casing mounted rigidly on a massive foundation.

  7. Adaptable System Increasing the Transmission Speed and Reliability in Packet Network by Optimizing Delay

    Directory of Open Access Journals (Sweden)

    Zbynek Kocur

    2014-01-01

    Full Text Available There is a great diversity in the transmission technologies in current data networks. Individual technologies are in most cases incompatible at physical and partially also at the link layer of the reference ISO/OSI model. Network compatibility, as the ability to transmit data, is realizable through the third layer, which is able to guarantee the operation of the different devices across their technological differences. The proposed inverse packet multiplexer addresses increase of the speed and reliability of packet transmission to the third layer, and at the same time it increases the stability of the data communication by the regulation of the delay value during the transmission. This article presents implementation of a communication system and its verification in real conditions. The conclusion compares the strengths and weaknesses of the proposed control system.

  8. A test of a 2 Tesla superconducting transmission line magnet system

    Energy Technology Data Exchange (ETDEWEB)

    Piekarz, Henryk; Carcagno, Ruben; Claypool, Brad; Foster, George W.; Hays, Steven L.; Huang, Yuenian; Kashikhin, Vladimir; Malamud, Ernest; Mazur, Peter O.; Nehring,; Oleck, Andrew; Rabehl, Roger; Schlabach, Phil; Sylvester, Cosmore; Velev, Gueorgui; Volk, James; /Fermilab; Wake, Masayoshi; /KEK, Tsukuba

    2005-09-01

    Superconducting transmission line magnet test system for an injector accelerator of a staged VLHC proton-proton colliding beam accelerator has been built and operated at Fermilab. The 1.5 m long, twin-aperture, combined function dipole magnet of 2 Tesla field is excited by a single turn 100 kA transmission line superconductor. The 100 kA dc current is generated using dc-dc switching converters powered by a bulk 240 kW supply. A pair of horizontally placed conventional leads facilitates transfer of this current to the magnet transmission line superconductor operating at liquid helium temperature. Fabrication of magnet components and magnet assembly work are described. The magnet test system and its operation are presented, and the performance is summarized.

  9. An Implementation of Low Cost and Low-power Network Broadcast Data Transmission and Storage System

    Science.gov (United States)

    Yi, Qing-Ming; Shi, Min; He, Yi-Hua

    A connectivity and realization method for the one-to-many remote network data transmission and storage was introduced in this paper. 3D LED display array needs large size data to display a stereo picture. This method was used in 3D LED display array to resolve data secure transmission problem. Combining the Intel 28FJ3A series Flash and Ethernet control chip DM9000A,it applied the Field-Programmable Gate Array (FPGA) and Verilog HDL programming technology to the system, implemented synchronic display and storage of stereograph, and reached 100 Mbps in the network transmission .Testing shows that the system is of low-cost,low-power and high-speed.

  10. Federal Emergency Management Information System (FEMIS) system administration guide, version 1.4.5

    Energy Technology Data Exchange (ETDEWEB)

    Arp, J.A.; Burnett, R.A.; Carter, R.J. [and others

    1998-06-26

    The Federal Emergency Management Information Systems (FEMIS) is an emergency management planning and response tool that was developed by the Pacific Northwest National Laboratory (PNNL) under the direction of the US Army Chemical Biological Defense Command. The FEMIS System Administration Guide provides information necessary for the system administrator to maintain the FEMIS system. The FEMIS system is designed for a single Chemical Stockpile Emergency Preparedness Program (CSEPP) site that has multiple Emergency Operations Centers (EOCs). Each EOC has personal computers (PCs) that emergency planners and operations personnel use to do their jobs. These PCs are connected via a local area network (LAN) to servers that provide EOC-wide services. Each EOC is interconnected to other EOCs via a Wide Area Network (WAN). Thus, FEMIS is an integrated software product that resides on client/server computer architecture. The main body of FEMIS software, referred to as the FEMIS Application Software, resides on the PC client(s) and is directly accessible to emergency management personnel. The remainder of the FEMIS software, referred to as the FEMIS Support Software, resides on the UNIX server. The Support Software provides the communication, data distribution, and notification functionality necessary to operate FEMIS in a networked, client/server environment. The UNIX server provides an Oracle relational database management system (RDBMS) services, ARC/INFO GIS (optional) capabilities, and basic file management services. PNNL developed utilities that reside on the server include the Notification Service, the Command Service that executes the evacuation model, and AutoRecovery. To operate FEMIS, the Application Software must have access to a site specific FEMIS emergency management database. Data that pertains to an individual EOC`s jurisdiction is stored on the EOC`s local server. Information that needs to be accessible to all EOCs is automatically distributed by the FEMIS

  11. Phronesis, a diagnosis and recovery tool for system administrators

    CERN Document Server

    Haen, C; Bonaccorsi, E; Neufeld, N

    2014-01-01

    The LHCb experiment relies on the Online system, which includes a very large and heterogeneous computing cluster. Ensuring the proper behavior of the different tasks running on the more than 2000 servers represents a huge workload for the small operator team and is a 24/7 task. At CHEP 2012, we presented a prototype of a framework that we designed in order to support the experts. The main objective is to provide them with steadily improving diagnosis and recovery solutions in case of misbehavior of a service, without having to modify the original applications. Our framework is based on adapted principles of the Autonomic Computing model, on Reinforcement Learning algorithms, as well as innovative concepts such as Shared Experience. While the submission at CHEP 2012 showed the validity of our prototype on simulations, we here present an implementation with improved algorithms and manipulation tools, and report on the experience gained with running it in the LHCb Online system.

  12. Hybrid wireless-over-fiber transmission system based on multiple injection-locked FP LDs.

    Science.gov (United States)

    Li, Chung-Yi; Lu, Hai-Han; Chu, Chien-An; Ying, Cheng-Ling; Lu, Ting-Chien; Peng, Peng-Chun

    2015-07-27

    A hybrid wireless-over-fiber (WoF) transmission system based on multiple injection-locked Fabry-Perot laser diodes (FP LDs) is proposed and experimentally demonstrated. Unlike the traditional hybrid WoF transmission systems that require multiple distributed feedback (DFB) LDs to support different kinds of services, the proposed system employs multiple injection-locked FP LDs to provide different kinds of applications. Such a hybrid WoF transmission system delivers downstream intensity-modulated 20-GHz microwave (MW)/60-GHz millimeter-wave (MMW)/550-MHz cable television (CATV) signals and upstream phase-remodulated 20-GHz MW signal. Excellent bit error rate (BER), carrier-to-noise ratio (CNR), composite second-order (CSO), and composite triple-beat (CTB) are observed over a 40-km single-mode fiber (SMF) and a 4-m radio frequency (RF) wireless transport. Such a hybrid WoF transmission system has practical applications for fiber-wireless convergence to provide broadband integrated services, including telecommunication, data communication, and CATV services.

  13. Transmission Performance Analysis of Fiber Optical Parametric Amplifiers for WDM System

    Directory of Open Access Journals (Sweden)

    Xiaohong Jiang

    2009-01-01

    Full Text Available A numerical analysis is presented on the long-haul wavelength-division multiplexing (WDM transmission system employing fiber-optic parametric amplifier (FOPA cascades based on one-pump FOPA model with Raman Effect taken into account. The end-to-end equalization scheme is applied to optimize the system features in terms of proper output powers and signal-to-noise ratios (SNRs in all the channels. The numerical results show that—through adjusting the fiber spans along with the number of FOPAs as well as the channel powers at the terminals in a prescribed way—the transmission distance and system performance can be optimized. By comparing the results generated by different lengths of fiber span, we come to the optimal span length to achieve the best transmission performance. Furthermore, we make a comparison among the long-haul WDM transmission systems employing different inline amplifiers, namely, FOPA, erbium-doped fiber amplifier (EDFA, and Fiber Raman Amplifier (FRA. FOPA demonstrates its advantage over the other two in terms of system features.

  14. A method of applying two-pump system in automatic transmissions for energy conservation

    Directory of Open Access Journals (Sweden)

    Peng Dong

    2015-06-01

    Full Text Available In order to improve the hydraulic efficiency, modern automatic transmissions tend to apply electric oil pump in their hydraulic system. The electric oil pump can support the mechanical oil pump for cooling, lubrication, and maintaining the line pressure at low engine speeds. In addition, the start–stop function can be realized by means of the electric oil pump; thus, the fuel consumption can be further reduced. This article proposes a method of applying two-pump system (one electric oil pump and one mechanical oil pump in automatic transmissions based on the forward driving simulation. A mathematical model for calculating the transmission power loss is developed. The power loss transfers to heat which requires oil flow for cooling and lubrication. A leakage model is developed to calculate the leakage of the hydraulic system. In order to satisfy the flow requirement, a flow-based control strategy for the electric oil pump is developed. Simulation results of different driving cycles show that there is a best combination of the size of electric oil pump and the size of mechanical oil pump with respect to the optimal energy conservation. Besides, the two-pump system can also satisfy the requirement of the start–stop function. This research is extremely valuable for the forward design of a two-pump system in automatic transmissions with respect to energy conservation and start–stop function.

  15. Stimulated Raman Effect in Bi—driectionally Amplified and Transmission WDM Systems

    Institute of Scientific and Technical Information of China (English)

    KanZHANG; AnshiXU

    1997-01-01

    One of the nonlinear effect-SRS effect in bi-directional WDM transmission systems is studied in this paper,Analytical and numerical results are given to show the effect of SRS.Systems with uni-and bi-directional EDFAs(Erbium doped fiber amplifiers0 are also considered.And a new method to deal with SRS effect in bi-directional systems is drawn out.

  16. Innovation on Energy Power Technology (8)First HVDC Transmission System in Japan

    Science.gov (United States)

    Sampei, Masatoshi

    This paper is an episode concerning the Hokkaido-Honshu HVDC Link that is the first High Voltage DC Current transmission system in Japan. The effort to the commissioning of the first stage of this system is explained. Moreover, it explains the research and development executed to achieve 600MW of this system that is the final stage. In addition, the adoption episode of the frequency control method introduced for Hokkaido-Honshu HVDC Link is explained.

  17. Lumped-element model of a tapered transmission line for impedance matching in a pulsed power system

    Science.gov (United States)

    Lee, Kun-A.; Ko, Kwang-Cheol

    2016-07-01

    In a pulsed power system, impedance matching is one of the significant factors for increasing the efficiency of the system. One of the most general methods for impedance matching is to use a tapered transmission line. Because the characteristics of a tapered transmission line are changed continuously according to its position, modeling the tapered transmission line by using lumped elements is difficult. In this study, we investigated a tapered transmission line to match the impedance of power supply to that of a load by using lumped elements especially in a pulsed power system. In modeling the tapered transmission line, we used the concept of a transmission, and we introduced an efficient modeling method. We propose a simulation model based on the investigation results. The results of the study will be useful for research on tapered transmission lines.

  18. Simulation of full duplex data transmission in ROF system using Optisystem

    Directory of Open Access Journals (Sweden)

    Sandeep Singh

    2012-06-01

    Full Text Available Wireless coverage of the end-user domain; be it outdoors or indoors, is poised to become an essential part of broadband communication networks. In order to offer integrated broadband services (combining voice, data, video, multimedia services, and new value added services, systems will need to offer higher data transmission capacities. The need for increased capacity per unit area leads to higher operating frequencies, smaller radio cells and large number of base stations (BSs, therefore cost-effective BS development is a key success to the market. For this radio over fiber (RoF technology has been proposed since it provides functionally simple BSs that are connected to a central station (CS via an optical fiber. A full-duplex data and video signal transmission over single-mode fiber (SMF based on wavelengthdivision-multiplexing (WDM and an optical add-drop multiplexing (OADM technique is proposed and simulated. Four data signals of 1.25 Gb/s /9.1-9.4GHz are transmitted over long-haul single-mode fiber for downlink transmission. For uplink transmission, four data signals, each from a BS, of 1.25 Gb/s/9.6-9.9GHz is used. Good bit error rate (BER performances were achieved for both down-link and up-link transmissions in our full-duplex RoF transport system.

  19. The study about torsional vibration charateristics and its optimization of vehicle transmission system

    Science.gov (United States)

    Huang, Yuxin; Xin, Qinkun; Yin, Huabing

    2010-06-01

    The torsional vibration of vehicle transmission system is heavily concerned with the increase of vehicle speed. The whole powertrain system has to be matched according to the torsional vibration characteristics, especially in developing a new vehicle. The selection of proper elastic coupling has to be made for the torsional vibration match and some frequencies have to be moved out of engine's range . Thus the torsional vibration model of powertrain needs to be built. In the paper a new torsional vibration model is built, which is programmed in the form of a platform. The whole powertrain system torsional vibration model of a vehicle is built firstly with consideration of gear mesh stiffness and engine's excitation in it. The free torsional vibration mode analysis is made and the resonant torques of each lumped inertia in the transmission system are obtained. Secondly the forced vibration of transmission system with the engine's excitation is made and the dynamic torques of each lumped inertias are obtained. Thirdly the process for the torsional vibration analysis is integrated into the optimization process and the selection of elastic coupling for the transmission system is made according the optimization and match results. Fourthly in order to modify the design parameters in the structural design, the sensitivities of inertia and torsional stiffness with reference to eigenvalues are obtained. At last the evaluations of analysis results are made and some suggestions for structural modification for engineers are presented. According to the above study, the conclusion can be made that the new torsional modelling method, the elastic coupling selection method and integration optimization method in the paper are practical and reliabl and these methods play very important roles in torsional vibration analyzing, match and optimization of vehicle transmission system.

  20. NASIS data base management system: IBM 360 TSS implementation. Volume 8: Data base administrator user's guide

    Science.gov (United States)

    1973-01-01

    The Data Base Administrator User's Guide for the NASA Aerospace Safety Information System is presented. The subjects discussed are: (1) multi-terminal tasking, (2) data base executive, (3) utilities, (4) maintenance, (5) terminal support, and (6) retrieval subsystem.

  1. The effect of age on systemic absorption and systemic disposition of bupivacaine after subarachnoid administration

    Energy Technology Data Exchange (ETDEWEB)

    Veering, B.T.; Burm, A.G.; Vletter, A.A.; van den Hoeven, R.A.; Spierdijk, J. (Leiden Univ. Hospital (Netherlands))

    1991-02-01

    In order to evaluate the role of the pharmacokinetics of the age-related changes in the clinical profile of spinal anesthesia with bupivacaine, we studied the influence of age on the systemic absorption and systemic disposition of bupivacaine after subarachnoid administration in 20 male patients (22-81 yr), ASA Physical Status 1 or 2, by a stable isotope method. After subarachnoid administration of 3 ml 0.5% bupivacaine in 8% glucose, a deuterium-labeled analog (13.4 mg) was administered intravenously. Blood samples were collected for 24 h. Plasma concentrations of unlabeled and deuterium-labeled bupivacaine were determined with a combination of gas chromatography and mass fragmentography. Biexponential functions were fitted to the plasma concentration-time data of the deuterium-labeled bupivacaine. The systemic absorption was evaluated by means of deconvolution. Mono- and biexponential functions were fitted to the data of fraction absorbed versus time. The maximal height of analgesia and the duration of analgesia at T12 increased with age (r = 0.715, P less than 0.001; r = 0.640, P less than 0.01, respectively). In 18 patients the systemic absorption of bupivacaine was best described by a biexponential equation. The half-life of the slow systemic absorption process (r = -0.478; P less than 0.05) and the mean absorption time (r = -0.551; P less than 0.02) decreased with age. The total plasma clearance decreased with age (r = -0.650, P less than 0.002), whereas the mean residence time and terminal half-life increased with age (r = 0.597, P less than 0.01; r = 0.503, P less than 0.05).

  2. LHCb: Phronesis, a diagnosis and recovery tool for system administrators

    CERN Multimedia

    Haen, C; Bonaccorsi, E; Neufeld, N

    2013-01-01

    The backbone of the LHCb experiment is the Online system, which is a very large and heterogeneous computing center. Making sure of the proper behavior of the many different tasks running on the more than 2000 servers represents a huge workload for the small expert-operator team and is a 24/7 task. At the occasion of CHEP 2012, we presented a prototype of a framework that we designed in order to support the experts. The main objective is to provide them with always improving diagnosis and recovery solutions in case of misbehavior of a service, without having to modify the original applications. Our framework is based on adapted principles of the Autonomic Computing model, on reinforcement learning algorithms, as well as innovative concepts such as Shared Experience. While the presentation made at CHEP 2012 showed the validity of our prototype on simulations, we here present a version with improved algorithms, manipulation tools, and report on experience with running it in the LHCb Online system.

  3. Advanced Error-Control Coding Methods Enhance Reliability of Transmission and Storage Data Systems

    Directory of Open Access Journals (Sweden)

    K. Vlcek

    2003-04-01

    Full Text Available Iterative coding systems are currently being proposed and acceptedfor many future systems as next generation wireless transmission andstorage systems. The text gives an overview of the state of the art initerative decoded FEC (Forward Error-Correction error-control systems.Such systems can typically achieve capacity to within a fraction of adB at unprecedented low complexities. Using a single code requires verylong code words, and consequently very complex coding system. One wayaround the problem of achieving very low error probabilities is turbocoding (TC application. A general model of concatenated coding systemis shown - an algorithm of turbo codes is given in this paper.

  4. Theories and technologies of electronic-electrical-mechanical integrated(EEMI)transmission system

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    @@ EEMI is one of the hot spots in cross-disciplinary research. The research in this topic was to discard the traditional mechanical gear reducer, integrate electrical motor with mechanical load, control the electrical motor by electrical power generated by microelectronics and electrical electronics; namely, form a EEMI transmission system in the mechanical equipments with low rotation rate and large rotation torque.

  5. A Seismic Transmission System for Continuous Monitoring of the Lithosphere: A Proposition

    NARCIS (Netherlands)

    Unger, R.

    2002-01-01

    The main objective of this thesis is to enhance earthquake prediction feasibility. We present the concept and the design layout of a novel seismic transmission system capable of continuously monitoring the Lithosphere for changes in Earth physics parameters governing seismic wave propagation. New-te

  6. Multi-Terabit Long-Haul Transmission System Utilizing Distributed Raman Amplification Technologies

    Institute of Scientific and Technical Information of China (English)

    Takao Naito; Toshiki Tanaka

    2003-01-01

    Here we summarize multi-terabit long-haul transmission experiment and distributed Raman amplification (DRA) technologies. As well, we investigate the configuration of dispersion-managed fibers for the DRA-based system from the viewpoint of the fiber non-linear effect and required pumping power.

  7. Condition Assessment of Ferrous Water Transmission and Distribution Systems State of Technology Review Report

    Science.gov (United States)

    This White Paper was developed to serve as the basis for discussion at a Technology Forum on Condition Assessment of Water Transmission and Distribution Systems that was held on September 9 and 10, 2008, at Edison, NJ. It was distributed to the Forum participants for review in a...

  8. Stability analysis of transmission system with high penetration of distributed generation

    NARCIS (Netherlands)

    Reza, M.

    2006-01-01

    Nowadays, interest in generating electricity using decentralized generators of relatively small scale ('distributed generation', DG) is increasing. This work deals with the impact of implementing DG on the transmission system transient stability, with the emphasis on a potential transition from a 'v

  9. Transmission modulation system for mobile phone reduces battery consumption without increasing bit error rate

    NARCIS (Netherlands)

    Moretti, M.; Janssen, G.J.M.

    2000-01-01

    The transmission modulation system minimizes the wasted 'out of band' power. The digital data (1) to be transmitted is fed via a pulse response filter (2) to a mixer (4) where it modulates a carrier wave (4). The digital data is also fed via a delay circuit (5) and identical filter (6) to a second m

  10. Secure Analog Data Transmission Based on Rössler Chaotic System Behavior

    OpenAIRE

    Daniel CURIAC; Ioan FILIP; Florin DRĂGAN

    2000-01-01

    This paper describes a new methodology for increasing the security of analog data transmission based on a mixture of the original analog signal with one of the state variables of Rössler chaotic system. The method is described emphasizing on the practical implementation aspects.

  11. Secure Analog Data Transmission Based on Rössler Chaotic System Behavior

    Directory of Open Access Journals (Sweden)

    Daniel CURIAC

    2000-12-01

    Full Text Available This paper describes a new methodology for increasing the security of analog data transmission based on a mixture of the original analog signal with one of the state variables of Rössler chaotic system. The method is described emphasizing on the practical implementation aspects.

  12. Optimization of Passive and Active Non-Linear Vibration Mounting Systems Based on Vibratory Power Transmission

    Science.gov (United States)

    Royston, T. J.; Singh, R.

    1996-07-01

    While significant non-linear behavior has been observed in many vibration mounting applications, most design studies are typically based on the concept of linear system theory in terms of force or motion transmissibility. In this paper, an improved analytical strategy is presented for the design optimization of complex, active of passive, non-linear mounting systems. This strategy is built upon the computational Galerkin method of weighted residuals, and incorporates order reduction and numerical continuation in an iterative optimization scheme. The overall dynamic characteristics of the mounting system are considered and vibratory power transmission is minimized via adjustment of mount parameters by using both passive and active means. The method is first applied through a computational example case to the optimization of basic passive and active, non-linear isolation configurations. It is found that either active control or intentionally introduced non-linearity can improve the mount's performance; but a combination of both produces the greatest benefit. Next, a novel experimental, active, non-linear isolation system is studied. The effect of non-linearity on vibratory power transmission and active control are assessed via experimental measurements and the enhanced Galerkin method. Results show how harmonic excitation can result in multiharmonic vibratory power transmission. The proposed optimization strategy offers designers some flexibility in utilizing both passive and active means in combination with linear and non-linear components for improved vibration mounts.

  13. Power Delivery in Multiterminal VSC-HVDC Transmission System for Offshore Wind Power Applications

    DEFF Research Database (Denmark)

    Silva, Rodrigo Da; Teodorescu, Remus; Rodriguez, Pedro

    2010-01-01

    This paper deals with one of the challenges in the field of offshore wind power systems: power transmission among the wind farms and the land when there is more than one AC grid to be considered. This case is known in the literature as multiterminal connection. The proposed studies are going to p...

  14. Interconnection of the power systems of the far east by using line HVDC transmission

    Directory of Open Access Journals (Sweden)

    Ilya Dydchenko

    2014-04-01

    Full Text Available The possibility of the interconnection continental part of the Russian Far East with the energy systems of Sakhalin and Japan. Indicate the technical possibility of this decision. The comparative analysis of the prospects for the construction of transmission lines of AC and DC. Proved the advantage of applying the lines of direct current for the interconnection of the Far East.

  15. Analysis and Simulation on Current Commutation of DC Transfer Switches in UHVDC Transmission Systems

    Institute of Scientific and Technical Information of China (English)

    PENG Chang; WEN Jialiang; MA Guohua; WANG Xiuhuan; LIU Zhigang; YU Kunshan

    2011-01-01

    The most severe working conditions of transfer switches in HVDC transmission systems identified as below: DC are For MRTB and GRTS, the most severe working condition is the failure of a single pole under operation mode. MRTB has to commutate the current from the ground return to metallic return. GRTS works in the contrary way.

  16. Effect of Polarization Dependent Loss on Polarization-Multiplexed Transmission System

    Institute of Scientific and Technical Information of China (English)

    H.; C.; Ji; J.; H.; Lee; K.; J.; Park; Y.; C.; Chung

    2003-01-01

    We report on the effects of the polarization-dependent loss (PDL) on the polarization-multiplexed system. The result shows that the PDL of 0.9 dB could cause 1-dB power penalty. Unlike PMD, the effect of PDL was not dependent on the transmission speed.

  17. 76 FR 44320 - Buckeye Power, Inc. v. American Transmission Systems, Incorporated; Notice of Complaint

    Science.gov (United States)

    2011-07-25

    ... Energy Regulatory Commission Buckeye Power, Inc. v. American Transmission Systems, Incorporated; Notice of Complaint Take notice that on July 18, 2011, pursuant to sections 206 and 306 of the Federal Power... (Commission), Buckeye Power, Inc. (Buckeye or Complainant) filed a formal complaint against...

  18. Operation and control of a DC-grid offshore wind farm under DC transmission system faults

    DEFF Research Database (Denmark)

    Deng, Fujin; Chen, Zhe

    2013-01-01

    So far, all existing offshore wind farms have an ac collection system, and the collected power in the offshore wind farm is sent to an onshore ac grid through high-voltage ac (HVAC) or DC (HVDC) transmission lines. However, future of fshore wind farms may use dc also for power collection. Consequ...

  19. Multiagent System-Based Distributed Coordinated Control for Radial DC Microgrid Considering Transmission Time Delays

    DEFF Research Database (Denmark)

    Dou, Chun-Xia; Yue, Dong; Guerrero, Josep M.

    2017-01-01

    This paper focuses on a multi-agent based distributed coordinated control for radial DC microgrid considering trans-mission time delays. Firstly, a two-level multi-agent system is constructed, where local control is formulated based on local states and executed by means of the first-level agent...

  20. Lightning location system for power transmission lines; Sodensen rakurai chiten no tanchi system

    Energy Technology Data Exchange (ETDEWEB)

    Kurihara, M. [Central Research Institute of Electric Power Industry, Tokyo (Japan)

    1996-04-01

    A novel Lightning Location System (LLS) for power transmission lines has been developed. In this system, an optical loop is constituted, wherein a light signal is reflected by an Optical Fiber Composite Ground Wire (OPGW) end, positioned opposite to the incident end, and returns to the incident end. When a lightning lands on an OPGW, the lightning current travels through the steel tower serving as the grounding route and, because the OPGW is a strand of aluminum-clad wires, produces a magnetic field in the OPGW along its longitudinal direction, which causes fluctuations in polarization simultaneously in the light signals traveling, up or down in the opposite directions, through the lightning-struck spot. When the fluctuations are observed at the receiving end, two fluctuations are detected with a certain time difference between the two, and the time difference is the required information because the time difference is equivalent to the time that is twice the time that a light signal requires to travel from the lightning-struck spot to the light-reflecting end. Accordingly, the distance from the lightning-struck spot can be calculated using the observed time difference. In actual observation in a lightning-abundant period of approximately two months and half, fluctuations in polarization were observed 51 times, and there was agreement on the order of second with the LLS lightning detecting time in 43 out of the 51. 5 refs., 3 figs.

  1. Perceived impact by administrators of psychiatric emergency services after changes in a state's mental health system.

    Science.gov (United States)

    Arfken, Cynthia L; Zeman, Lori Lackman; Koch, Alison

    2006-06-01

    As a safety net, psychiatric emergency services are sensitive to system changes. To determine the impact of a state's changes in its mental health system, administrators of publicly funded psychiatric emergency services were surveyed. They reported few (M=0.8) negative changes in coordination of care but 77% endorsed change in administrative burden (54% saying it negatively affected quality of services). Reporting negative effect of administrative burden was associated with treating more persons with substance abuse problems and greater challenge posed by distance to local providers. These results suggest that impact of state-level changes was not uniform but associated with local characteristics.

  2. Clinical systemic lupeol administration for canine oral malignant melanoma.

    Science.gov (United States)

    Yokoe, Inoru; Azuma, Kazuo; Hata, Keishi; Mukaiyama, Toshiyuki; Goto, Takahiro; Tsuka, Takeshi; Imagawa, Tomohiro; Itoh, Norihiko; Murahata, Yusuke; Osaki, Tomohiro; Minami, Saburo; Okamoto, Yoshiharu

    2015-01-01

    Canine oral malignant melanoma (COMM) is the most aggressive malignant tumor in dogs. Lupeol is a triterpene extracted from various fruits and vegetables that reportedly inhibits melanoma cell proliferation in vitro and in vivo. In this study, the efficacy of subcutaneous lupeol for spontaneous COMM was evaluated. A total of 11 dogs (3, 5 and 3 dogs diagnosed with clinical stage I, II and III melanoma, respectively) were evaluated. Subcutaneous lupeol (10 mg/kg) was administered postoperatively at various time points to treat these 11 COMM cases. Of the 11 subjects, 7 exhibited no local recurrence 180 days postoperatively and no severe adverse effects were observed in any of the cases. Furthermore, no distant metastasis was observed during the experimental period. Therefore, systemic lupeol may prevent local tumor progression and distant metastasis and may be a novel adjuvant treatment for the treatment of COMM.

  3. An examination of the vibration transmissibility of the hand-arm system in three orthogonal directions.

    Science.gov (United States)

    Welcome, Daniel E; Dong, Ren G; Xu, Xueyan S; Warren, Christopher; McDowell, Thomas W; Wu, John Z

    2015-02-01

    The objective of this study is to enhance the understanding of the vibration transmission in the hand-arm system in three orthogonal directions (X, Y, and Z). For the first time, the transmitted vibrations distributed on the entire hand-arm system exposed in the three orthogonal directions via a 3-D vibration test system were measured using a 3-D laser vibrometer. Seven adult male subjects participated in the experiment. This study confirms that the vibration transmissibility generally decreased with the increase in distance from the hand and it varied with the vibration direction. Specifically, to the upper arm and shoulder, only moderate vibration transmission was measured in the test frequency range (16 to 500 Hz), and virtually no transmission was measured in the frequency range higher than 50 Hz. The resonance vibration on the forearm was primarily in the range of 16-30 Hz with the peak amplitude of approximately 1.5 times of the input vibration amplitude. The major resonance on the dorsal surfaces of the hand and wrist occurred at around 30-40 Hz and, in the Y direction, with peak amplitude of more than 2.5 times of the input amplitude. At higher than 50 Hz, vibration transmission was effectively limited to the hand and fingers. A major finger resonance was observed at around 100 Hz in the X and Y directions and around 200 Hz in the Z direction. In the fingers, the resonance magnitude in the Z direction was generally the lowest, and the resonance magnitude in the Y direction was generally the highest with the resonance amplitude of 3 times the input vibration, which was similar to the transmissibility at the wrist and hand dorsum. The implications of the results are discussed.

  4. 146-GHz millimeter-wave radio-over-fiber photonic wireless transmission system.

    Science.gov (United States)

    Fice, M J; Rouvalis, E; van Dijk, F; Accard, A; Lelarge, F; Renaud, C C; Carpintero, G; Seeds, A J

    2012-01-16

    We report the experimental implementation of a wireless transmission system with a 146-GHz carrier frequency which is generated by optical heterodyning the two modes from a monolithically integrated quantum dash dual-DFB source. The monolithic structure of the device and the inherent low noise characteristics of quantum dash gain material allow us to demonstrate the transmission of a 1 Gbps ON-OFF keyed data signal with the two wavelengths in a free-running state at 146-GHz carrier wave frequency. The tuning range of the device fully covers the W-band (75 - 110 GHz) and the F-band (90 - 140 GHz).

  5. Performance evaluation of modulation formats in 40×40-Gb/s WDM repeaterless transmission systems

    Institute of Scientific and Technical Information of China (English)

    Guangshan Lu; Kun Xu; Jian Wu; Jintong Lin

    2006-01-01

    @@ Transmission performance of six modulation formats is numerically compared in 40 × 40-Gb/s wavelength division multiplexing (WDM) repeaterless systems. The results indicate that return-to-zero differential phase shift keying (RZ-DPSK) (33% duty cycle) demonstrates the best performance among all the formats when the accumulated amplified spontaneous emission power (AASEP) is small. But with the increasing of AASEP, the superiority of RZ-DPSK transmission performance over the other five modulation formats is vanished. AASEP is justified to be the major source for the deterioration of the superiority.

  6. Low-power system-on-chip implementation for respiratory rate detection and transmission.

    Science.gov (United States)

    Padasdao, Bryson; Yee, Roxanne; Boric-Lubecke, Olga

    2012-01-01

    Recent biosensors can measure respiratory rate non-invasively, but limits patient mobility or requires regular battery replacement. Respiratory effort, which can scavenge mW, may power the sensor, but requires minimal sensor power usage. This paper demonstrates feasibility of respiratory rate measurement by using a comparator instead of ADC. A low-power system-on-chip can implement respiratory rate detection and wireless data transmission with a total power consumption under 82 µW. This approach produces significant power savings, and transmission uses under 30% of total power consumption.

  7. Influence of fiber parameters on the performance of a SCM_QPSK transmission system

    Science.gov (United States)

    Togneri, Arnaldo P.; Segatto, Marcelo E. V.; Pontes, Maria José; Giraldi, Maria Thereza M. R.; Costa, J. C. W. A.

    2006-04-01

    The performance of a Subcarrier Multiplexing (SCM) optical fibre system using QPSK modulation is analysed in this paper. Our results will show that it is possible to increase the system bandwidth by controlling the input optical power. Various fibre dispersion values and subcarrier channel spacing are used in order to check the bandwidth increase proportional to the optical power. The transmission bandwidth was studied in terms of fibre dispersion and input optical power. The frequency response was measured and computed. Limitations imposed by nonlinear distortions mainly due to interplay between dispersion and self-phase modulation are verified as well. The analysis to the SCM_QPSK transmission system such as the subcarrier channel spacing, signal input power, available frequency bandwidth under the fibre specifications and system conditions operation will be explored in a specific application. It means applying this technique after setting the requirements necessary to the operation of an optical ground-wire (OPGW) already installed system. The results showed an increase of the transmission bandwidth as the optical power increases. For QPSK modulation, power penalties smaller than 1 dB were obtained only for channel spacing higher than 1.2 multiplied by the symbol rate. Experimental measurements obtained in the literature were used to validate our results. Eye opening and received eye diagrams will be evaluated in order to have a simpler receiver layout and make the entire system more reliable, since it will become more robust to error disturbance, maintenance is easier and system upgrades will be facilitated.

  8. Voltage Balancing Method on Expert System for 51-Level MMC in High Voltage Direct Current Transmission

    Directory of Open Access Journals (Sweden)

    Yong Chen

    2016-01-01

    Full Text Available The Modular Multilevel Converters (MMC have been a spotlight for the high voltage and high power transmission systems. In the VSC-HVDC (High Voltage Direct Current based on Voltage Source Converter transmission system, the energy of DC link is stored in the distributed capacitors, and the difference of capacitors in parameters and charge rates causes capacitor voltage balance which affects the safety and stability of HVDC system. A method of MMC based on the expert system for reducing the frequency of the submodules (SMs of the IGBT switching frequency is proposed. Firstly, MMC with 51 levels for HVDC is designed. Secondly, the nearest level control (NLC for 51-level MMC is introduced. Thirdly, a modified capacitor voltage balancing method based on expert system for MMC-based HVDC transmission system is proposed. Finally, a simulation platform for 51-level Modular Multilevel Converter is constructed by using MATLAB/SIMULINK. The results indicate that the strategy proposed reduces the switching frequency on the premise of keeping submodule voltage basically identical, which greatly reduces the power losses for MMC-HVDC system.

  9. Adaptive transmission schemes for MISO spectrum sharing systems: Tradeoffs and performance analysis

    KAUST Repository

    Bouida, Zied

    2014-10-01

    In this paper, we propose a number of adaptive transmission techniques in order to improve the performance of the secondary link in a spectrum sharing system. We first introduce the concept of minimum-selection maximum ratio transmission (MS-MRT) as an adaptive variation of the existing MRT (MRT) technique. While in MRT all available antennas are used for transmission, MS-MRT uses the minimum subset of antennas verifying both the interference constraint (IC) to the primary user and the bit error rate (BER) requirements. Similar to MRT, MS-MRT assumes that perfect channel state information (CSI) is available at the secondary transmitter (ST), which makes this scheme challenging from a practical point of view. To overcome this challenge, we propose another transmission technique based on orthogonal space-time block codes with transmit antenna selection (TAS). This technique uses the full-rate full-diversity Alamouti scheme in order to maximize the secondary\\'s transmission rate. The performance of these techniques is analyzed in terms of the average spectral efficiency (ASE), average number of transmit antennas, average delay, average BER, and outage performance. In order to give the motivation behind these analytical results, the tradeoffs offered by the proposed schemes are summarized and then demonstrated through several numerical examples.

  10. A Simplified Scheme of Estimation and Cancellation of Companding Noise for Companded Multicarrier Transmission Systems

    Directory of Open Access Journals (Sweden)

    S. Peng

    2015-04-01

    Full Text Available Nonlinear companding transform is an efficient method to reduce the high peak-to-average power ratio (PAPR of multicarrier transmission systems. However, the introduced companding noise greatly degrades the bit-error-rate (BER performance of the companded multicarrier systems. In this paper, a simplified but effective scheme of estimation and cancellation of companding noise for the companded multicarrier transmission system is proposed. By expressing the companded signals as the summation of original signals added with a companding noise component, and subtracting this estimated companding noise from the received signals, the BER performance of the overall system can be significantly improved. Simulation results well confirm the great advantages of the proposed scheme over other conventional decompanding or no decompanding schemes under various situations.

  11. Learning from the blackouts. Transmission system security in competitive electricity markets

    Energy Technology Data Exchange (ETDEWEB)

    none

    2005-07-01

    Electricity market reform has fundamentally changed the environment for maintaining reliable and secure power supplies. Growing inter-regional trade has placed new demands on transmission systems, creating a more integrated and dynamic network environment with new real-time challenges for reliable and secure transmission system operation. Despite these fundamental changes, system operating rules and practices remain largely unchanged. The major blackouts of 2003 and 2004 raised searching questions about the appropriateness of these arrangements. Management of system security needs to be transformed to maintain reliable electricity services in this more dynamic operating environment. These challenges raise fundamental issues for policymakers. This publication presents case studies drawn from recent large-scale blackouts in Europe, North America, and Australia. It concludes that a comprehensive, integrated policy response is required to avoid preventable large-scale blackouts in the future.

  12. Reduction of PAPR and Efficient detection ordering scheme for MIMO Transmission Systems Using Power Control

    Directory of Open Access Journals (Sweden)

    V.Sreevani

    2015-12-01

    Full Text Available The technical challenges for communication engineers is the development of best performance wireless networks with negligible amount of distortions. We have to consider multipath propagation attenuation and radio spectrum inefficiency. Now a days, In MIMO (Multi Input Multi Output systems there is a huge demand for the networks with the high transmission rates and better quality of service which are having low PAPR ratio. Instead of OFDMA, filter banks are used in massive MIMO to reduce the complexity. But they are error prone to noise. This base paper discusses about PAPR reduction in MIMO systems using different precoding based OFDM systems. Mainly, minimization of multi-antenna systems by controlling the transmission power and reduction of PAPR using ZC (Zadoff-Chu matrix transform.

  13. Investigation of broadband digital predistortion for broadband radio over fiber transmission systems

    Science.gov (United States)

    Zhang, Xiupu; Liu, Taijun; Shen, Dongya

    2016-12-01

    In future broadband cloud radio access networks (C-RAN), front-haul transmission systems play a significant role in performance and cost of C-RAN. Broadband and high linearity radio over fiber (RoF) transmission systems are considered a promising solution for the front-haul. Digital linearization is one possible solution for RoF front-haul. In this paper, we investigate RF domain digital predistortion (DPD) linearization for broadband RoF front-haul. The implemented DPD is first investigated in 2.4 GHz WiFi over fiber transmission systems at 36 Mb/s, and more than 8-dB and 5.6-dB improvements of error vector magnitude (EVM) are achieved in back to back (BTB) and after 10 km single mode fiber (SMF) transmission. Further, both WiFi and ultra wide band (UWB) wireless signals are transmitted together, in which the DPD has linearization bandwidth of 2.4 GHz. It is shown that the implemented DPD leads to EVM improvements of 4.5-dB (BTB) and 3.1-dB (10 km SMF) for the WiFi signal, and 4.6-dB (BTB) and 4-dB (10 km SMF) for the broadband UWB signal.

  14. Design and Analysis of the Gemini Chain System in Dual Clutch Transmission of Automobile

    Institute of Scientific and Technical Information of China (English)

    CHENG Yabing; GUO Haitao; FU Zhenming; WAN Nen; LI Lei; WANG Yang

    2015-01-01

    Chain drive system is widely used in the conditions of high-speed, overload, variable speed and load. Many studies are focused on the meshing theory and wear characteristics of chain drive system, but system design, analysis, and noise characteristics of the chain drive system are weak. System design and noise characteristic are studied for a new type Gemini chain of dual-clutch automatic transmission. Based on the meshing theory of silent chain, the design parameters of the Gemini chain system are calculated and the mathematical models and dynamic analysis models of the Gemini chain system are established. Dynamic characteristics of the Gemini chain system is simulated and the contact force of plate and pin, plate and sprockets, the chain tension forces, the transmission error and the stress of plates and pins are analyzed. According to the simulation results of the Gemini chain system, the noise experiment about system is carried out. The noise values are tested at different speed and load and spectral characteristics are analyzed. The results of simulation and experimental show that the contact forces of plate and pin, plate and sprockets are smaller than the allowable stress values, the chain tension force is less than ultimate tension and transmission error is limited in 1.2%. The noise values can meet the requirements of industrial design, and it is proved that the design and analysis method of the Gemini chain system is scientific and feasible. The design and test system is built from analysis to test of Gemini chain system. This research presented will provide a corresponding theoretical guidance for the design and dynamic characteristics and noise characteristics of chain drive system.

  15. Design and analysis of the Gemini chain system in dual clutch transmission of automobile

    Science.gov (United States)

    Cheng, Yabing; Guo, Haitao; Fu, Zhenming; Wan, Nen; Li, Lei; Wang, Yang

    2015-01-01

    Chain drive system is widely used in the conditions of high-speed, overload, variable speed and load. Many studies are focused on the meshing theory and wear characteristics of chain drive system, but system design, analysis, and noise characteristics of the chain drive system are weak. System design and noise characteristic are studied for a new type Gemini chain of dual-clutch automatic transmission. Based on the meshing theory of silent chain, the design parameters of the Gemini chain system are calculated and the mathematical models and dynamic analysis models of the Gemini chain system are established. Dynamic characteristics of the Gemini chain system is simulated and the contact force of plate and pin, plate and sprockets, the chain tension forces, the transmission error and the stress of plates and pins are analyzed. According to the simulation results of the Gemini chain system, the noise experiment about system is carried out. The noise values are tested at different speed and load and spectral characteristics are analyzed. The results of simulation and experimental show that the contact forces of plate and pin, plate and sprockets are smaller than the allowable stress values, the chain tension force is less than ultimate tension and transmission error is limited in 1.2%. The noise values can meet the requirements of industrial design, and it is proved that the design and analysis method of the Gemini chain system is scientific and feasible. The design and test system is built from analysis to test of Gemini chain system. This research presented will provide a corresponding theoretical guidance for the design and dynamic characteristics and noise characteristics of chain drive system.

  16. Power flow transmission in a coupled flexible system with active executive elements

    Institute of Scientific and Technical Information of China (English)

    HUO Rui; SHI Yin; SONG Kongjie

    2002-01-01

    Based on its prototype of machine-isolator-foundation systems, a theoretical model for dynamic coupled linear system is established, in which both the passive and active control factors are considered. Power flow is used as the cost function to evaluate the isolation effectiveness. And the transmission of vibratory power flow from a vibrating rigid body into a simply supported thin panel through passive isolators and actuators is investigated numerically. The active control strategy is summarized in the conclusion.

  17. Dynamic Simulations of Combined Transmission and Distribution Systems using Parallel Processing Techniques

    OpenAIRE

    Aristidou, P; Van Cutsem, T

    2014-01-01

    Simulating a power system with both transmission and distribution networks modeled in detail is a huge computational challenge. In this paper, we propose a Schur-complement-based domain decomposition algorithm to provide accurate, detailed dynamic simulations of the combined system. The simulation procedure is accelerated with the use of parallel programming techniques, taking advantage of the parallelization opportunities inherent in domain decomposition algorithms. The proposed algorithm is...

  18. A Parallel Processing Approach to Dynamic Simulations of Combined Transmission and Distribution Systems

    OpenAIRE

    Aristidou, P; Van Cutsem, T

    2015-01-01

    Simulating a power system with both transmission and distribution networks modeled in detail is a huge computational challenge. In this paper, a Schur-complement-based domain decomposition algorithm is proposed to provide accurate, detailed dynamic simulations of such systems. The simulation procedure is accelerated with the use of parallel programming techniques, taking advantage of the parallelization opportunities inherent to domain decomposition algorithms. The proposed algorithm is gener...

  19. Compact transmission system using single-sideband modulation of light for quantum cryptography.

    Science.gov (United States)

    Duraffourg, L; Merolla, J M; Goedgebuer, J P; Mazurenko, Y; Rhodes, W T

    2001-09-15

    We report a new transmission that can be used for quantum key distribution. The system uses single-sideband-modulated light in an implementation of the BB84 quantum cryptography protocol. The system is formed by two integrated unbalanced Mach-Zehnder interferometers and is based on interference between phase-modulated sidebands in the spectral domain. Experiments show that high interference visibility can be obtained.

  20. Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-140- SalemAlbany1)

    Energy Technology Data Exchange (ETDEWEB)

    Sherer, Brett M. [Bonneville Power Administration, Portland, OR (United States)

    2003-04-04

    Bonneville Power Administration (BPA) proposes to remove unwanted vegetation along the right-of- way, access roads, switch platforms, microwave beam paths, and around tower structures of the subject transmission line corridor that may impede the operation and maintenance of the identified transmission lines. BPA plans to conduct vegetation control with the goal of removing tall growing vegetation that is currently or will soon be a hazard to the transmission line. BPA’s overall goal is to have low-growing plant communities along the rights-of-way to control the development of potentially threatening vegetation.

  1. Evaluation and Verification of Channel Transmission Characteristics of Human Body for Optimizing Data Transmission Rate in Electrostatic-Coupling Intra Body Communication System: A Comparative Analysis.

    Directory of Open Access Journals (Sweden)

    Yuhwai Tseng

    Full Text Available Intra-body communication is a new wireless scheme for transmitting signals through the human body. Understanding the transmission characteristics of the human body is therefore becoming increasingly important. Electrostatic-coupling intra-body communication system in a ground-free situation that integrate electronic products that are discretely located on individuals, such as mobile phones, PDAs, wearable computers, and biomedical sensors, are of particular interest.The human body is modeled as a simplified Resistor-Capacitor network. A virtual ground between the transmitter and receiver in the system is represented by a resister-capacitor network. Value of its resistance and capacitance are determined from a system perspective. The system is characterized by using a mathematical unit step function in digital baseband transmission scheme with and without Manchester code. As a result, the signal-to-noise and to-intersymbol-interference ratios are improved by manipulating the load resistor. The data transmission rate of the system is optimized. A battery-powered transmitter and receiver are developed to validate the proposal.A ground-free system fade signal energy especially for a low-frequency signal limited system transmission rate. The system transmission rate is maximized by simply manipulating the load resistor. Experimental results demonstrate that for a load resistance of 10k-50k Ω, the high-pass 3 dB frequency of the band-pass channel is 400kHz-2MHz in the worst-case scenario. The system allows a Manchester-coded baseband signal to be transmitted at speeds of up to 20M bit per second with signal-to-noise and signal-to-intersymbol-interference ratio of more than 10 dB.The human body can function as a high speed transmission medium with a data transmission rate of 20Mbps in an electrostatic-coupling intra-body communication system. Therefore, a wideband signal can be transmitted directly through the human body with a good signal

  2. Improving the Transmission System Reliability for the 154kV Radial Network Operation

    Energy Technology Data Exchange (ETDEWEB)

    Choo, Jin Boo; Yoo, Myeong Ho; Yoon, Young Beum; Kim, Tae Won [Korea Electric Power Research Institute, Taejon (Korea, Republic of); Lee, Gi Won; Chung, Beom Jin; Jung, Jung Won; Park, Kyu Hyun; Lee, Myung Hee; Kim, Hyun Jong; Kim, Chae Hee [KEYIN CO., (Korea, Republic of)

    1996-12-31

    Analyzing that 154kV radial network current ed operated, we developed Automatic Power Reconfiguration System(APRS) which restore blackout area. It consists of special data acquisition system(DAU) and central monitoring system for reason of protecting currently operating power system. In addition, it communicates using optical communication network for high speed data transmission and accuracy. An Accuracy of operation and stability of the developed system is tested using Real Time Digital Simulator in 3-bus equivalent model system. In An Outage case, our developed system can restore a blackout area in three second. An ability of the restoration of a blackout was verified by simulations. For the field test, the developed system was set up at SINCHON S/S, SESOMUN S/S, SINDANG S/S and MAJANG S/S governed by Seoul Power Transmission Center. If the system reliability is proved for a one year test in real power system, application of the system will be extended to the other substations.

  3. THz Wireless Transmission Systems Based on Photonic Generation of Highly Pure Beat-Notes

    DEFF Research Database (Denmark)

    Jia, Shi; Yu, Xianbin; Hu, Hao

    2016-01-01

    noise of photonically generated THz beat-notes when phase correlation of two optical comb tones is damaged due to their path-length difference. In addition, we demonstrate THz wireless transmission of various modulation formats, including OOK, QPSK, 16-QAM, and 32-QAM at beyond 10 Gb/s in such a system......In this paper, a terahertz (THz) wireless communication system at 400 GHz with various modulation formats [on–off keying (OOK), quadrature phase-shift keying (QPSK), 16-quadrature amplitude modulation (16-QAM), and 32-quadrature amplitude modulation (32-QAM)] is experimentally demonstrated based...... on photonic generation of highly pure THz carriers. The experimental THz wireless photonic transmission system is enabled by the ultrawideband behavior of an antenna-integrated unitraveling-carrier-photodiode-based transmitter and a Schottky mixer-based THz receiver. In the experiment, a phase...

  4. A Categorization of Converter Station Controllers Within Multi-terminal DC Transmission Systems

    DEFF Research Database (Denmark)

    Irnawan, Roni; Silva, Filipe Miguel Faria da; Bak, Claus Leth;

    2016-01-01

    As more and more VSC-HVDC links are planned and commissioned, interconnection of neighboring links or connection to an existing link becomes a feasible step towards secure and reliable multi-terminal DC (MTDC) transmission systems. Multi-vendor MTDC (MV-MTDC) operation is anticipated as an impact...... of this gradual DC grids development. In order to achieve certain operation conditions, DC grid controller needs to send specific control settings to individual converter station controls. One of the challenges in MV-MTDC transmission systems occurs in coordination of converters since different types...... of controller might exist in the same system. It is therefore important to identify the parameters required by the converter station controllers to ensure a smooth coordination. In this paper, different converter station controllers available in the literatures are categorized. Challenges of converter station...

  5. Sensitivity analysis and dynamic modification of modal parameter in mechanical transmission system

    Institute of Scientific and Technical Information of China (English)

    2005-01-01

    Sensitivity analysis is one of the effective methods in the dynamic modification. The sensitivity of the modal parameters such as the natural frequencies and mode shapes in undamped free vibration of mechanical transmission system is analyzed in this paper.In particular,the sensitivities of the modal parameters to physical parameters of shaft system such as the inertia and stiffness are given.A calculation formula for dynamic modification is presented based on the analysis of modal parameter.With a mechanical transmission system as an example, the sensitivities of natural frequencies and modes shape are calculated and analyzed. Furthermore, the dynamic modification is also carried out and a good result is obtained.

  6. Modeling and Power Flow Analysis for Herringbone Gears Power Dual-Branching Transmission System

    Science.gov (United States)

    Yang, Xiaofang; Zhu, Yanxiang; Fang, Zongde; Gu, Jiangong

    Based on power dual-branching transmission system of herringbone gears, the mechanical structural model was established. This study represented the simplified algorithm to obtain its power flow situations through formulating the deformation compatibility condition for the linear relationship between the torque and transverse deformation of tooth surface and the torque equilibrium condition. Besides, the effects on the power flow of system were calculated under all kinds of the installation error and processing error of gear pairs. Finally, the power flow situations of dual branches were solved via Programming. A numerical example that illustrated the developed theory was provided. The research results can be applied to analyze the actual application of herringbone gears power split-path transmission system.

  7. Power Flow Analysis of HVAC and HVDC Transmission Systems for Offshore WindParks

    DEFF Research Database (Denmark)

    da Silva, Filipe Miguel Faria; Castro, Rui

    2009-01-01

    , the two options are analysed from a power flow point of view. The influence in the voltage regulation of the onshore connection busbar is investigated in a 57 bus test power system. The simulation results obtained for each one of the above mentioned transmission system configurations allow the conclusion......As the onshore wind resource is running shorter, wind power promoters are paying attention to the offshore resources. As in most cases there is no load offshore, wind power must be transmitted to the main land. To do so, two options are available: HVAC and HVDC transmission systems. In this paper...... that HVAC solution is limited by the distance to shore and by the wind transmitted power. HVDC options do not show these limitations, but are more expensive and more delicate to deal with, because there is a lack of operational experience, so far....

  8. Accurate one-end fault location for overhead transmission lines in interconnected power systems

    Energy Technology Data Exchange (ETDEWEB)

    Eisa, Amir A.A.; Ramar, K. [Faculty of Engineering, Multimedia University, 63100 Cyberjaya (Malaysia)

    2010-06-15

    This paper presents a new one-end fault location method for overhead transmission lines embedded in a general n-bus interconnected power system. High accuracy in fault location is achieved by using both an accurate distributed parameters model for the faulted transmission line, and a two-bus Thevenin equivalent network model for the power system that accurately accounts for its interconnectivity. The method has been tested using transient fault data obtained from PSCAD/EMTDC simulations of an 11-bus interconnected power system. The results obtained indicate that the method is capable of estimating the fault distance with high accuracy for various fault conditions. They also indicate that method is sensitive to errors in the value of the local bus impedance, but is insensitive to errors in the value of the remote bus impedance. (author)

  9. Video Transmission over MIMO-OFDM System: MDC and Space-Time Coding-Based Approaches

    Directory of Open Access Journals (Sweden)

    Haifeng Zheng

    2007-03-01

    Full Text Available MIMO-OFDM is a promising technique for the broadband wireless communication system. In this paper, we propose a novel scheme that integrates multiple-description coding (MDC, error-resilient video coding, and unequal error protection strategy with hybrid space-time coding structure for robust video transmission over MIMO-OFDM system. The proposed MDC coder generates multiple bitstreams of equal importance which are very suitable for multiple-antennas system. Furthermore, according to the contribution to the reconstructed video quality, we apply unequal error protection strategy using BLAST and STBC space-time codes for each video bitstream. Experimental results have demonstrated that the proposed scheme can be an excellent alternative to achieve desired tradeoff between the reconstructed video quality and the transmission efficiency.

  10. Application of the Wireless Digital Transmission Technology in Remote ECG Monitoring System

    Institute of Scientific and Technical Information of China (English)

    Xu,Lixin; Li,Qingliang; Chen,Zhen; Qi,Xinbo; Zhang,Xincheng

    2005-01-01

    Heart disease is one of the main diseases menace human' s health. The limited monitoring ability and limited serving ability are shortcomings of the existing remote ECG (electrocardiograph) monitoring system. It is practical to bring ECG monitoring from hospital to home. A new method is introduced that the application of wireless digital transmission technology in remote ECG monitoring system. In the system, the portable ECG monitoring device to collect and transmit patient""s electrocardiogram signals and the device to transmit and receive ECG signals are designed by using the PTR2000. The method solves the remote collection and transmission of patient's electrocardiogram signals, and creates the condition of the transmitting of patient"" s electrocardiogram signals through the Broadband network.

  11. Application of the Wireless Digital Transmission Technology in Remote ECG Monitoring System

    Institute of Scientific and Technical Information of China (English)

    Xu,Lixin; Li,Qingliang; Chen,Zhen; Qi,Xinbo; Zhang,Xincheng

    2005-01-01

    Heart disease is one of the main diseases menace human's health. The limited monitoring ability and limited serving ability are shortcomings of the existing remote ECG (electrocardiograph) monitoring system. It is practical to bring ECG monitoring from hospital to home. A new method is introduced that the application of wireless digital transmission technology in remote ECG monitoring system. In the system, the portable ECG monitoring device to collect and transmit patient's electrocardiogram signals and the device to transmit and receive ECG signals are designed by using the PTR2000. The method solves the remote collection and transmission of patient s electrocardiogram signals, and creates the condition of the transmitting of patient's electrocardiogram signals through the Broadband network.

  12. MDP-based resource allocation for triple-play transmission on xDSL systems

    Science.gov (United States)

    de Souza, Lamartine V.; de Carvalho, Glaucio H. S.; Cardoso, Diego L.; de Carvalho, Solon V.; Frances, Carlos R. L.; Costa, João C. W. A.; Riu, Jaume Rius i.

    2007-09-01

    Many broadband services are based on multimedia applications, such as voice over internet protocol (VoIP), video conferencing, video on demand (VoD), and internet protocol television (IPTV). The combination "triple-play" is often used with IPTV. It simply means offering voice, video and data. IPTV and others services uses digital broadband networks such as ADSL2+ (Asymmetric Digital Subscriber Line) and VDSL (Very High Rate DSL) to transmit the data. We have formulated a MDP (Markov Decision Process) for a triple-play transmission on DSL environment. In this paper, we establish the relationship between DSL transmission characteristics and its finite-state Markov model for a triple-play transmission system. This relationship can be used for a resource management for multimedia applications delivered through a broadband infrastructure. The solution to our optimization problem can be found using dynamic programming (DP) techniques, such as value iteration and its variants. Our study results in a transmission strategy that chooses the optimal resource allocation according the triple-play traffic requirements, defined in technical report TR-126 (Triple-Play Services Quality of Experience Requirements) from DSL Forum, minimizing quality of service (QoS) violations with respect to bandwidth. Three traffic classes (video, audio, and best effort internet data) are defined and analyzed. Our simulation results show parameters like as blocking probability for each class, link utilization and optimal control policies. The MDP-based approach provides a satisfactory way of resource management for a DSL system.

  13. Assessing the effect of zooprophylaxis on zoonotic cutaneous leishmaniasis transmission: a system dynamics approach.

    Science.gov (United States)

    Kaabi, Belhassen; Ahmed, Sami Ben-hadj

    2013-12-01

    Capturing or diverting the disease carrying vector from humans can reduce the transmission of vector borne diseases such as leishmaniasis. The use of animals that act as dead-end hosts to relieve the vector (sandfly) bites on humans is called zooprophylaxis. However, as the number of blood meal providers especially domestic animals increases, the sandflies enhanced availability of blood meals will improve its number and survival, thereby countering the impact of diverting bites from humans. Thus, the transmission model exhibits the structure of a feedback loop characterizing complex dynamic systems. In order to rigorously assess the effect of zooprophylaxis, we propose a system dynamic model for zoonotic cutaneous leishmaniasis transmission with 3 blood-meal hosts: domestic animals, humans, and a reservoir (rodents). In this context, a simulation study of the proposed model with a follow-up period of 1000 days was performed. We explored how perturbations in the parameters characterizing the transmission, essentially the vector biting rates and the size of the domestic animal population, affect the zooprophylaxis outcome. The results show that the basic reproductive number R0 and the disease incidence in humans are decreasing function of the relative size of the domestic animal population. The speed of this decrease depends also on the vector biting rates of the different mammal species. The key factors influencing the magnitude of zooprophylaxis are: the sizes of the vector, rodent, and domestic animal populations, as well as, the biting rates which incorporate relative attraction and accessibility of the vectors to the mammalian populations.

  14. The design of high-speed data transmission method for a small nuclear physics DAQ system

    CERN Document Server

    Zhou, Wenxiong; Nan, Gangyang; Zhang, Jianchuan

    2013-01-01

    A large number of data need to be transmitted in high-speed between Field Programmable Gate Array (FPGA) and Advanced RISC Machines 11 micro-controller (ARM11) when we design a small data acquisition (DAQ) system for nuclear experiments. However, it is a complex problem to beat the target. In this paper, we will introduce a method which can realize the high-speed data transmission. By this way, FPGA is designed to acquire massive data from Front-end electronics (FEE) and send it to ARM11, which will transmit the data to other computer through the TCP/IP protocol. This paper mainly introduces the interface design of the high-speed transmission between FPGA and ARM11, the transmission logic of FPGA and the driver program of ARM11. The research shows that the maximal transmission speed between FPGA and ARM11 by this way can reach 50MB/s theoretically, while in nuclear physics experiment, the system can acquire data with the speed of 2.2MB/s.

  15. Re-engineering land administration systems for sustainable development — from rhetoric to reality

    Science.gov (United States)

    Williamson, Ian P.

    Current land administration systems are the product of 19th century economic and land market paradigms and have failed to properly support sustainable development. The need for urgent reform is accepted, but the way forward unclear in many jurisdictions. This paper will discuss current international initiatives and research to develop a new land administration vision to promote sustainable development. Within this context, this paper describes the changing humankind to land relationship, identifies some of the growing environmental pressures facing modern society and the need for sustainable development, explores the evolving role of land administration in society and highlights the need for land administration systems to play a more proactive role in supporting sustainable development objectives. The process to re-engineer land administrations is briefly reviewed. The paper then highlights the development of a national land administration vision and strategy. In proposing strategies the paper draws on international trends and experiences such as highlighted in the recent United Nations — International Federation of Surveyors Declaration on Land Administration for Sustainable Development.

  16. Serial Failure Diagnosis of a Transmission Line Protection Relaying System by Petri Nets

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    With the development of large-scale complicated modern power systems, the requirement for the associatedprotection scheme tends to be more stringent and its combination more complex. However, it is very difficult to figureout the factors of failure of such systems. This paper proposes a Petri net model of a transmission line protectionrelaying system, including three types of relays as well as an automatic re-closing device, and shows how to diagnoseserial failure of the system by analyzing invariant sets of the model. Furthermore, it gives four basic types of failuresequences and its execution is much more intuitive and effective than the traditional method.

  17. Optimization of the transmission system for wavelength routed optical network: trade-off between node complexity and transmission channel utilization

    DEFF Research Database (Denmark)

    Limal, Emmanuel; Hjelme, Dag Roar; Stubkjær, Kristian Elmholdt

    1998-01-01

    We study the influence of the number of wavelengths per fibre and the line bit rate on network dimensions and transmission capacity utilisation for wavelength routed optical transport networks. The networks considered are of European scale, and the traffic matrices used are projections of a traffic...

  18. Design and Realization of a New Signal Security System for Multimedia Data Transmission

    Directory of Open Access Journals (Sweden)

    Hun-Chen Chen

    2003-12-01

    Full Text Available We propose a new signal security system and its VLSI architecture for real-time multimedia data transmission applications. We first define two bit-circulation functions for one-dimensional binary array transformation. Then, we exploit a chaotic system in generating a binary sequence to control the bit-circulation functions defined for performing the successive transformation on the input data. Each eight 8-bit data elements is regarded as a set and is fed into an 8×8 binary matrix being transformed on each row and each column of the matrix by these two bit-circulation functions such that the signal can be transformed into completely disordered data. The features of the proposed design include low computational complexity, regular operations suitable for low-cost VLSI implementation, high data security, and high feasibility for easy integration with commercial multimedia storage and transmission applications. We have performed Matlab simulation to verify the functional correctness of the proposed system. In implementing the system, a low-cost VLSI architecture has been designed, verified, and physically realized based on a 0.35 μm CMOS technology. The implementation results show that the proposed signal security system can achieve 117 Mbytes/s data throughput rate that is fast enough for real-time data protection in multimedia transmission applications.

  19. Both acute and prolonged administration of EPO reduce cerebral and systemic vascular conductance in humans

    DEFF Research Database (Denmark)

    Rasmussen, Peter; Kim, Yu-Sok; Krogh-Madsen, Rikke;

    2012-01-01

    Administration of erythropoietin (EPO) has been linked to cerebrovascular events. EPO reduces vascular conductance, possibly because of the increase in hematocrit. Whether EPO in itself affects the vasculature remains unknown; here it was evaluated in healthy males by determining systemic...... and cerebrovascular variables following acute (30,000 IU/d for 3 d; n=8) and chronic (5000 IU/week for 13 wk; n=8) administration of EPO, while the responsiveness of the vasculature was challenged during cycling exercise, with and without hypoxia. Prolonged administration of EPO increased hematocrit from 42.5 ± 3...

  20. DPSK-DWT OFDM SYSTEM FOR RELIABLE DATA TRANSMISSION USING BARCODE SYSTEM IN MOBILE DEVICES

    OpenAIRE

    E. Akhila*, K. Ramesh

    2016-01-01

    DPSK-OFDM modulation scheme is implemented in the proposed work to handle the complexity issue in flexible manner for hassle-free data transmission in mobile devices. Barcode scheme has ability to convert the readable form of information into un-understandable form to provide complexity free transmission. Barcode printed on paper has interference free appearance which does not have any leakages while digital barcodes has observed while pixels are leaked into their corresponding black pixels w...

  1. The Mathematical Model of Power System with Thyristor Controlled Series Capacitor in Long Transmission Line

    Directory of Open Access Journals (Sweden)

    Prechanon Kumkratug

    2012-01-01

    Full Text Available Problem statement: It is becoming increasingly important to fully utilize the existing transmission system assets due to environmental legislation, rights-of-way issues and costs of construction and deregulation policies that introduced in recent years. The Thyristor Controlled Series Capacitor (TCSC has been proposed for the better control power flow and dynamic performance. The exact long transmission line model consists of the resistance and reactance. Most of previous researches studies transient stability performance of the TCSC in SMIB System with neglecting the resistance of the line. Thus the fully capability of the TCSC on transient stability improvement of power system may not be applied. The consideration of the resistance causes in the difficulty of deriving the mathematical model. Approach: This study investigates the effect of the TCSC on transient stability of the power system with consideration the exact long transmission line mode. The concept of two-port network is applied to simplify the mathematical model of the power system. The proposed method is tested on sample system and compared on various cases. Results: The first swing of rotor angle curve of the faulted system without resistance is obviously higher than that of with resistance whereas the second swing of the faulted system without resistance is slightly less than that of with resistance. The system with a TCSC can improve transient stability of power system. Conclusion: It was found from this study that the TCSC and resistance of the line can improve first swing of rotor angle. However, the resistance of the line provides the negative effect on second swing of rotor angle. The simulation results indicate that for practical long line, the resistance is very import parameters for evaluating transient stability of power system.

  2. Vibration transmission through rolling element bearings. Part III: Geared rotor system studies

    Science.gov (United States)

    Lim, T. C.; Singh, R.

    1991-11-01

    This paper extends the proposed bearing matrix formulation of Parts I and II to analyze the overall dynamics of a geared rotor system which includes a spur gear pair, shafts, rolling element bearing, a prime mover and a load (attached to the geared rotor system through flexible torsional couplings), a rigid or flexible casing, and compliant or massive mounts. Linear time-invariant, discrete dynamic models of a generic geared rotor system with proportional viscous damping are developed, by using lumped parameter and dynamic finite element techniques, which are then used to predict the vibration transmissibility through bearings and mounts, casing vibration motion, and dynamic response of the internal rotating system. Each rotating shaft is modeled as an Euler beam in the lumped parameter model and as a Timoshenko beam in the dynamic finite element model, but the gyroscopic moment is not included. Eigensolution and forced harmonic response studies due to rotating mass unbalance or kinematic transmission error excitation for the following example cases are obtained by using the formulation, and the results are compared with those of simple models currently available in the literature and/or experiment: case I, a single-stage rotor system with flexibly mounted rigid casing consisting of two bearings as a special case of the geared rotor system; case II, a spur gear pair drive supported by four bearings installed in a flexibly mounted rigid casing; and case III, an experimental set-up consisting of a high-precision gear and pinion, and four identical rolling element bearings contained in a flexible casing mounted rigidly on a massive foundation. Analytical predictions show that the theory is indeed capable of predicting bearing and mount moment transmissibilities in addition to the force transmissibilities. Also, flexural vibrations of the casing plate are predicted well as the theory is in good agreement with measurements made on case III; such predictions are not

  3. Impact of Distribution-Connected Large-Scale Wind Turbines on Transmission System Stability during Large Disturbances: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Y.; Allen, A.; Hodge, B. M.

    2014-02-01

    This work examines the dynamic impacts of distributed utility-scale wind power during contingency events on both the distribution system and the transmission system. It is the first step toward investigating high penetrations of distribution-connected wind power's impact on both distribution and transmission stability.

  4. Mass Drug Administration and beyond: how can we strengthen health systems to deliver complex interventions to eliminate neglected tropical diseases?

    Science.gov (United States)

    2015-01-01

    Achieving the 2020 goals for Neglected Tropical Diseases (NTDs) requires scale-up of Mass Drug Administration (MDA) which will require long-term commitment of national and global financing partners, strengthening national capacity and, at the community level, systems to monitor and evaluate activities and impact. For some settings and diseases, MDA is not appropriate and alternative interventions are required. Operational research is necessary to identify how existing MDA networks can deliver this more complex range of interventions equitably. The final stages of the different global programmes to eliminate NTDs require eliminating foci of transmission which are likely to persist in complex and remote rural settings. Operational research is required to identify how current tools and practices might be adapted to locate and eliminate these hard-to-reach foci. Chronic disabilities caused by NTDs will persist after transmission of pathogens ceases. Development and delivery of sustainable services to reduce the NTD-related disability is an urgent public health priority. LSTM and its partners are world leaders in developing and delivering interventions to control vector-borne NTDs and malaria, particularly in hard-to-reach settings in Africa. Our experience, partnerships and research capacity allows us to serve as a hub for developing, supporting, monitoring and evaluating global programmes to eliminate NTDs.

  5. CONTROL STRATEGY OF A PARALLEL HYBRID CAR WITH A METAL BELT-PLANETARY GEAR CONTINUOUSLY VARIABLE TRANSMISSION SYSTEM

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    The most remarkable characteristic of a metal belt-planetary gear continuously variable transmission is a wider ratio range and a bigger torque capacity than a conventional metal pushing belt continuously variable transmission. A parallel hybrid car with this transmission system not only can reduce fuel consumption and pollutant emission at a ECE city cycle, but also can keep the motor working in the most efficiency area and can be started by a lower power motor by oneself. At the same time, the continuously variable transmission system can realize the smooth switch between the motor and the engine.

  6. Real-time all-optical OFDM transmission system based on time-domain optical fourier transformation

    DEFF Research Database (Denmark)

    Guan, Pengyu; Kong, Deming; Røge, Kasper Meldgaard

    2014-01-01

    We propose a novel simple all-optical OFDM transmission system based on time-domain OFT using time-lenses. A real-time 160 Gbit/s DPSK OFDM transmission with 16 decorrelated data subcarriers is successfully demonstrated over 100 km.......We propose a novel simple all-optical OFDM transmission system based on time-domain OFT using time-lenses. A real-time 160 Gbit/s DPSK OFDM transmission with 16 decorrelated data subcarriers is successfully demonstrated over 100 km....

  7. An Evaluation of Open Source Learning Management Systems According to Administration Tools and Curriculum Design

    Science.gov (United States)

    Ozdamli, Fezile

    2007-01-01

    Distance education is becoming more important in the universities and schools. The aim of this research is to evaluate the current existing Open Source Learning Management Systems according to Administration tool and Curriculum Design. For this, seventy two Open Source Learning Management Systems have been subjected to a general evaluation. After…

  8. Diagnosis of multi-agent systems and its application to public administration

    NARCIS (Netherlands)

    A. Boer; T. van Engers

    2011-01-01

    In this paper we present a model-based diagnosis view on the complex social systems in which large public administration organizations operate. The purpose of diagnosis as presented in this paper is to identify agent role instances that are not conforming to expectations in a multi-agent system (MAS

  9. Data communication between data terminal equipment and the JPL administrative data base management system

    Science.gov (United States)

    Iverson, R. W.

    1984-01-01

    Approaches to enabling an installed base of mixed data terminal equipment to access a data base management system designed to work with a specific terminal are discussed. The approach taken by the Jet Propulsion Laboratory is described. Background information on the Jet Propulsion Laboratory (JPL), its organization and a description of the Administrative Data Base Management System is included.

  10. A unified modeling and control design for precision transmission system with friction and backlash

    Directory of Open Access Journals (Sweden)

    Xiulan Bao

    2016-05-01

    Full Text Available The structural flexibility, nonlinear friction, and backlash are the major factors limiting the control performance of precision transmission systems. If uncompensated, these factors compromise the positioning and tracking accuracy of precision transmission systems and even cause limit cycles and oscillation. In this article, a framework for integrated design from dynamic modeling to controller design is proposed. A multi-state dynamic model is presented, which can unify the modeling for a multi-state, discontinuous system including the motor state, the motion state, the mechanical contact state, and the friction state. Then, a control design method related to the dynamic modeling using perturbation separation of the model parameters is presented. Using the proposed modeling method, a continuous dynamic model is established to include all different partition models. The model comprehensively describes the mechanical and electrical characteristics of the precision transmission system. A robust controller is designed using the proposed control method. Experimental results demonstrate that the proposed modeling method is accurate and the proposed control method significantly improves accuracy and robustness of the controller compared to traditional control methods.

  11. Design of a telemetry system based on wireless power transmission for physiological parameter monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Jia, Zhiwei, E-mail: jiayege@hotmail.com [College of Electrical and Information Engineering, Changsha University of Science and Technology, Changsha (China); Yan, Guozheng; Zhu, Bingquan [820 Institute, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai (China)

    2015-04-15

    An implanted telemetry system for experimental animals with or without anaesthesia can be used to continuously monitor physiological parameters. This system is significant not only in the study of organisms but also in the evaluation of drug efficacy, artificial organs, and auxiliary devices. The system is composed of a miniature electronic capsule, a wireless power transmission module, a data-recording device, and a processing module. An electrocardiograph, a temperature sensor, and a pressure sensor are integrated in the miniature electronic capsule, in which the signals are transmitted in vitro by wireless communication after filtering, amplification, and A/D sampling. To overcome the power shortage of batteries, a wireless power transmission module based on electromagnetic induction was designed. The transmitting coil of a rectangular-section solenoid and a 3D receiving coil are proposed according to stability and safety constraints. Experiments show that at least 150 mW of power could pick up on the load in a volume of Φ10.5 mm × 11 mm, with a transmission efficiency of 2.56%. Vivisection experiments verified the feasibility of the integrated radio-telemetry system.

  12. Safety awareness educational topics for the construction of power transmission systems with smart grid technologies

    Directory of Open Access Journals (Sweden)

    Bryan Hubbard

    2013-09-01

    Full Text Available Power transmission facilities in the U.S. are undergoing a transformation due to the increased use of distributed generation sources such as wind and solar power.  The current power grid system is also antiquated and in need of substantial retrofits to make it more efficient and reliable.  The new energy transmission system being designed and built to optimize power delivery is known as “Smart Grid”.  The increased activity in the construction of power transmission facilities and installation of new technologies into the current power system raises potential safety concerns.  Existing construction management curriculum may include general information about safety training, but does not typically include information about this specialized sector.  The objective of this study was to work with industry to identify key safety topics appropriate for inclusion in an introductory industrial construction course.  Results of interviews with industry identified numerous hazards that are not typically covered in typical construction curricula.  A joint undergraduate and graduate course in industrial construction was created to address these and additional concepts. A survey of the students was performed to determine the effectiveness of the course and also to determine their thoughts about the smart grid technologies and safety training. Information on electrical system hazards is presented along with results of the student surveys.

  13. Seismic Response of Power Transmission Tower-Line System Subjected to Spatially Varying Ground Motions

    Directory of Open Access Journals (Sweden)

    Li Tian

    2010-01-01

    Full Text Available The behavior of power transmission tower-line system subjected to spatially varying base excitations is studied in this paper. The transmission towers are modeled by beam elements while the transmission lines are modeled by cable elements that account for the nonlinear geometry of the cables. The real multistation data from SMART-1 are used to analyze the system response subjected to spatially varying ground motions. The seismic input waves for vertical and horizontal ground motions are also generated based on the Code for Design of Seismic of Electrical Installations. Both the incoherency of seismic waves and wave travel effects are accounted for. The nonlinear time history analytical method is used in the analysis. The effects of boundary conditions, ground motion spatial variations, the incident angle of the seismic wave, coherency loss, and wave travel on the system are investigated. The results show that the uniform ground motion at all supports of system does not provide the most critical case for the response calculations.

  14. Power transfer capability assessment of transmission interfaces with SVC and load shedding systems

    Energy Technology Data Exchange (ETDEWEB)

    Pavlovsky, V. [DMCC-Engineering, Kiev (Ukraine). Inst. of Electrodynamics; Dolzhenitsa, Y. [DMCC Engineering, Kiev (Ukraine); Ushapovskiy, K. [National Power Co. Ukrenergo, Kiev (Ukraine)

    2009-07-01

    As a result of deregulation in the power industry, energy trade and markets are pushing transmission system operators to operate their systems closer to the edge of the power transfer capability. Voltage instability and inadequate reactive power support of generators is a key factor in most major outages around the world. The ideal way to control power systems is to avoid emergencies by reliable planning and secure operation of power systems. Therefore, the accurate calculation of the power transfer capability of transmission interfaces is an important task on the planning and operation stages. This paper discussed the issue of transfer capability assessment and monitoring for interfaces with static var compensator (SVC) and load shedding schemes. It also proposed a special measure, a distance to voltage instability point, to monitor transfer capability on-line. The distance may be observed by measurement of SVC output. The paper considered the problem of optimal SVC size selection and a new approach was proposed based on P-V curves analysis. The paper discussed the problem formulation and proposed approach. A case was also presented in order to demonstrate the proposed approach on the IPS Ukraine-Crimea interface. It was concluded that the proposed approach allows the optimal rating of SVC for increasing transfers capability of transmission corridors. 12 refs., 9 figs.

  15. Multichannel Adaptive Polarization Mode Dispersion Compensation with One Compensator in Dense Wavelength Division Multiplexing Transmission Systems

    Institute of Scientific and Technical Information of China (English)

    ZHANG Qi; CHEN Ming-hua; ZHANG Ji-yu; XIE Shi-zhong

    2007-01-01

    A simple two-section polarization mode dispersion(PMD) compensator is proposed for multichannel PMD compensation, which can compensate two or even more channels simultaneously. Because of the statistical characteristics and the frequency-dependence of PMD, for current single mode fiber with moderate PMD, the probability that all channels are severely degraded at the same time is extremely small, which makes it possible to compensate a dense wavelength division multiplexing(DWDM) transmission system with moderate PMD using this compensator. It is shown that the outage probability of a 40×43Gb/s DWDM transmission system using this compensator is decreased significantly from 3.6×10-3 to 3.6×10-5.

  16. A low-power high-speed ultra-wideband pulse radio transmission system.

    Science.gov (United States)

    Wei Tang; Culurciello, E

    2009-10-01

    We present a low-power high-speed ultra-wideband (UWB) transmitter with a wireless transmission test platform. The system is specifically designed for low-power high-speed wireless implantable biosensors. The integrated transmitter consists of a compact pulse generator and a modulator. The circuit is fabricated in the 0.5-mum silicon-on-sapphire process and occupies 420 mum times 420 mum silicon area. The transmitter is capable of generating pulses with 1-ns width and the pulse rate can be controlled between 90 MHz and 270 MHz. We built a demonstration/testing system for the transmitter. The transmitter achieves a 14-Mb/s data rate. With 50% duty cycle data, the power consumption of the chip is between 10 mW and 21 mW when the transmission distance is from 3.2 to 4 m. The core circuit size is 70 mum times 130 mum.

  17. Sensor selection of helicopter transmission systems based on physical model and sensitivity analysis

    Institute of Scientific and Technical Information of China (English)

    Lyu Kehong; Tan Xiaodong; Liu Guanjun; Zhao Chenxu

    2014-01-01

    In the helicopter transmission systems, it is important to monitor and track the tooth damage evolution using lots of sensors and detection methods. This paper develops a novel approach for sensor selection based on physical model and sensitivity analysis. Firstly, a physical model of tooth damage and mesh stiffness is built. Secondly, some effective condition indicators (CIs) are presented, and the optimal CIs set is selected by comparing their test statistics according to Mann-Kendall test. Afterwards, the selected CIs are used to generate a health indicator (HI) through sen slop estimator. Then, the sensors are selected according to the monotonic relevance and sensitivity to the damage levels. Finally, the proposed method is verified by the simulation and experimental data. The results show that the approach can provide a guide for health monitor-ing of helicopter transmission systems, and it is effective to reduce the test cost and improve the system’s reliability.

  18. Sensor selection of helicopter transmission systems based on physical model and sensitivity analysis

    Directory of Open Access Journals (Sweden)

    Lyu Kehong

    2014-06-01

    Full Text Available In the helicopter transmission systems, it is important to monitor and track the tooth damage evolution using lots of sensors and detection methods. This paper develops a novel approach for sensor selection based on physical model and sensitivity analysis. Firstly, a physical model of tooth damage and mesh stiffness is built. Secondly, some effective condition indicators (CIs are presented, and the optimal CIs set is selected by comparing their test statistics according to Mann–Kendall test. Afterwards, the selected CIs are used to generate a health indicator (HI through sen slop estimator. Then, the sensors are selected according to the monotonic relevance and sensitivity to the damage levels. Finally, the proposed method is verified by the simulation and experimental data. The results show that the approach can provide a guide for health monitoring of helicopter transmission systems, and it is effective to reduce the test cost and improve the system’s reliability.

  19. Identification of problems when using long high voltage AC cable in transmission system I: Switching transient problems

    DEFF Research Database (Denmark)

    Rahimi, Saeed; Wiechowski, W.; Randrup, M;

    2008-01-01

    area in early 1990s. Recently, the Danish TSO Energinet.dk has initiated a research project for analyzing the HV underground cable in transmission system. The objective of this paper and the companion paper is to address the most important problems expected in transmission system with relatively larger......Due to political and environmental pressures from the public and government side, upgrading and building new transmission facilities are becoming more and more difficult and in some cases the expansion of overhead transmission lines are impossible. This means that underground cable technology...... is the proper substitution and solution which make the transmission expansion possible with minimized visual impacts on the communities. Within European countries, Denmark was been at the forefront of replacing the transmission lines with cables. The project was supplying the power to the greater Copenhagen...

  20. A SECURE MESSAGE TRANSMISSION SYSTEM ARCHITECTURE FOR COMPUTER NETWORKS EMPLOYING SMART CARDS

    Directory of Open Access Journals (Sweden)

    Geylani KARDAŞ

    2008-01-01

    Full Text Available In this study, we introduce a mobile system architecture which employs smart cards for secure message transmission in computer networks. The use of smart card provides two security services as authentication and confidentiality in our design. The security of the system is provided by asymmetric encryption. Hence, smart cards are used to store personal account information as well as private key of each user for encryption / decryption operations. This offers further security, authentication and mobility to the system architecture. A real implementation of the proposed architecture which utilizes the JavaCard technology is also discussed in this study.

  1. Analysis of the ITER low field side reflectometer transmission line system.

    Science.gov (United States)

    Hanson, G R; Wilgen, J B; Bigelow, T S; Diem, S J; Biewer, T M

    2010-10-01

    A critical issue in the design of the ITER low field side reflectometer is the transmission line (TL) system. A TL connects each launcher to a diagnostic instrument. Each TL will typically consist of ∼42 m of corrugated waveguide and up to ten miter bends. Important issues for the performance of the TL system are mode conversion and reflections. Minimizing these issues are critical to minimizing standing waves and phase errors. The performance of TL system is analyzed and recommendations are given.

  2. Shaft torsional oscillation interactions between turbo-generators in parallel in series compensated transmission systems

    Energy Technology Data Exchange (ETDEWEB)

    Mello, F.P. de

    1994-12-31

    Several investigators have raised the possibility of interaction between shaft systems of parallel units, particularly among identical units. The question addressed in this paper is the significance of this interaction between shaft systems of units coupled through the electrical system. A time domain model of two parallels units connected to an infinite bus trough a series compensated transmission is used to evaluate the phenomena. The same model is used to extract pertinent frequency response functions by Fourier processing of pulse response tests from which a frequency response analysis is performed to lend additional insight into the phenomena. (author) 8 refs., 13 figs., 3 tabs.

  3. Guiding Principles in Selecting AC To DC Converters For Power Factor Corrections in AC Transmission System

    Directory of Open Access Journals (Sweden)

    Ibekwe B.E

    2014-10-01

    Full Text Available The ac to dc converters’ power factors correction in ac transmission system were investigated. The studies include: phase-controlled converter; pulse width modulated (PWM converter and ac input current shaped converter. Using Fourier series, power factors of these converters were calculated and simulated using MATLAB. The resulting curves are displayed in the hard copies for practical guides in the choice of converters; and comparatively, current shaped type is the best.

  4. 10Gb/s Bang-Bang Clock and Data Recovery (CDR for optical transmission systems

    Directory of Open Access Journals (Sweden)

    N. Dodel

    2005-01-01

    Full Text Available A Bang-Bang Clock-Data Recovery (CDR for 10Gb/s optical transmission systems is presented. A direct modulated architecture is used for the design. Its loop characteristics can be derived using an analogy to Σ Δ theory. The circuit was produced and measured in a commercial 0.25μm BiCMOS technology with a transition frequency fT70=GHz.

  5. 10Gb/s Bang-Bang Clock and Data Recovery (CDR) for optical transmission systems

    OpenAIRE

    N. Dodel; Klar, H.

    2005-01-01

    A Bang-Bang Clock-Data Recovery (CDR) for 10Gb/s optical transmission systems is presented. A direct modulated architecture is used for the design. Its loop characteristics can be derived using an analogy to Σ Δ theory. The circuit was produced and measured in a commercial 0.25μm BiCMOS technology with a transition frequency fT70=GHz.

  6. Precision power generator system for a single-wire electric power transmission

    OpenAIRE

    2014-01-01

    The article contains an example of the construction of precision oscillator operating frequency based of the chip AD 9832 company Аnalog Devices that implements the method of direct digital synthesis (DDS) and high-frequency power circuit for a system of single-wire electric power transmission which supports functions digital installations of the operating frequency.The use of DDS frequency synthesizer allows you to build a precision oscillator with a unique digital certainty: the signal gene...

  7. Analysis of electromagnetic interference from power system processing and transmission components for Space Station Freedom

    Science.gov (United States)

    Barber, Peter W.; Demerdash, Nabeel A. O.; Hurysz, B.; Luo, Z.; Denny, Hugh W.; Millard, David P.; Herkert, R.; Wang, R.

    1992-01-01

    The goal of this research project was to analyze the potential effects of electromagnetic interference (EMI) originating from power system processing and transmission components for Space Station Freedom. The approach consists of four steps: (1) developing analytical tools (models and computer programs); (2) conducting parameterization (what if?) studies; (3) predicting the global space station EMI environment; and (4) providing a basis for modification of EMI standards.

  8. A Common Definition of the System Operators' Core Activities[Electric Power Transmission System Operator

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-02-15

    In this report a common definition of the system operator's core activities in the Nordic countries is identified and also a list of non-core activities is introduced. As a starting point the common tasks for system responsibility as identified by Nordel has been used for the work. The term TSO (Transmission System Operator) is employed as a common denominator in the report. It is found out that the TSOs carry out common core activities in the roles as a transmission operator, a system operator and a balance settlement responsible. The core activities for the TSO as a transmission network operator are: Maintain the adequate transmission system in the long run and network development plan on the national as well as on the Nordic level using sophisticated analysis and planning methods and tools. Plan the transmission network on the national as well as on the Nordic level utilising new investments, renewal and maintenance of existing network components so that the network is secure to operate and adequate transmission capacity is guaranteed. Aim at timely network expansions using enhanced information exchange between the Nordic TSOs, and on the national level between the TSO and distribution and regional network operators, large consumers and large producers. Secure the technical compatibility with networks across the border and within a country by establishing connection requirements on the national level and ensuring that the national requirements are compatible across the Nordic power system. The core activities for the TSO as a system operator are: Define common technical requirements for the secure system operation using common planning, operation, connection and data exchange procedures. Secure the system operation with the operational planning for the following year by using information exchange between TSOs enabling the TSOs to make the best possible forecast of the global grid situation in order to assess the flows in their network and the available

  9. Partial PIC-MRC Receiver Design for Single Carrier Block Transmission System over Multipath Fading Channels

    Directory of Open Access Journals (Sweden)

    Juinn-Horng Deng

    2012-01-01

    Full Text Available Single carrier block transmission (SCBT system has become one of the most popular modulation systems due to its low peak-to-average power ratio (PAPR, and it is gradually considered to be used for uplink wireless communication systems. In this paper, a low complexity partial parallel interference cancellation (PIC with maximum ratio combining (MRC technology is proposed to use for receiver to combat the intersymbol interference (ISI problem over multipath fading channel. With the aid of MRC scheme, the proposed partial PIC technique can effectively perform the interference cancellation and acquire the benefit of time diversity gain. Finally, the proposed system can be extended to use for multiple antenna systems to provide excellent performance. Simulation results reveal that the proposed low complexity partial PIC-MRC SIMO system can provide robust performance and outperform the conventional PIC and the iterative frequency domain decision feedback equalizer (FD-DFE systems over multipath fading channel environment.

  10. Reduction of the visual impact of overhead transmission line systems through utilisation of line surge arresters as lightning protection

    DEFF Research Database (Denmark)

    Sørensen, Thomas Kjærsgaard; Holbøll, Joachim

    2008-01-01

    The main reason for the increasing public resistance to overhead transmission line systems in Denmark is the impact on the environment with emphasis on the visual aspect. Therefore the Danish Transmission System Operator Energinet.dk is currently carrying out a research project, in cooperation...... with the Technical University of Denmark, on how to lessen the visual impact of 400 kV overhead line transmission systems. In this paper omission of shield wires combined with installation of a suitable number of line surge arresters is investigated as a possible alternative to transmission lines equipped...... of the line and the required protection level in substations. The use of line surge arresters gives the possibility to decrease the height of towers thereby improving the visual impression of the overhead line transmission systems. However the usage of line surge arresters will, dependent upon line surge...

  11. A stable high-speed rotational transmission system based on nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Cai, Kun, E-mail: caikun1978@163.com [College of Water Resources and Architectural Engineering, Northwest A and F University, Yangling 712100 (China); State Key Laboratory of Structural Analysis for Industrial Equipment, Department of Engineering Mechanics, Faculty of Vehicle Engineering and Mechanics, Dalian University of Technology, Dalian 116024 (China); Yin, Hang; Wei, Ning [College of Water Resources and Architectural Engineering, Northwest A and F University, Yangling 712100 (China); Chen, Zhen [State Key Laboratory of Structural Analysis for Industrial Equipment, Department of Engineering Mechanics, Faculty of Vehicle Engineering and Mechanics, Dalian University of Technology, Dalian 116024 (China); Department of Civil and Environmental Engineering, University of Missouri, Columbia, Missouri 65211-2200 (United States); Shi, Jiao [Department of Civil and Environmental Engineering, University of Missouri, Columbia, Missouri 65211-2200 (United States)

    2015-01-12

    A stable rotational transmission system is designed with a single-walled carbon nanotube (SWCNT)-based motor and double-walled carbon nanotubes (DWCNTs)-based bearing. The system response is investigated using molecular dynamics (MD) simulation. It is found that the rotating motor can actuate the rotation of the inner tube in bearing because of the attraction between the two adjacent coaxial ends of motor and rotor (the inner tube in bearing). To have a stable nanostructure, each carbon atom on the adjacent ends of motor and rotor is bonded with a hydrogen atom. To obtain a stable high-speed rotational transmission system, both an armchair and a zigzag model are used in MD simulation. In each model, the motor with different diameters and rotational speeds is employed to examine the rotational transmission of corresponding DWCNTs. It is demonstrated that the long range van der Waals interaction between the adjacent ends of motor and rotor leads to a stable configuration of the adjacent ends, and further leads to a stable rotation of rotor when driven by a high-speed motor. As compared with the armchair model, the rotor in the zigzag model could reach a stable rotation mode much easier.

  12. A stable high-speed rotational transmission system based on nanotubes

    Science.gov (United States)

    Cai, Kun; Yin, Hang; Wei, Ning; Chen, Zhen; Shi, Jiao

    2015-01-01

    A stable rotational transmission system is designed with a single-walled carbon nanotube (SWCNT)-based motor and double-walled carbon nanotubes (DWCNTs)-based bearing. The system response is investigated using molecular dynamics (MD) simulation. It is found that the rotating motor can actuate the rotation of the inner tube in bearing because of the attraction between the two adjacent coaxial ends of motor and rotor (the inner tube in bearing). To have a stable nanostructure, each carbon atom on the adjacent ends of motor and rotor is bonded with a hydrogen atom. To obtain a stable high-speed rotational transmission system, both an armchair and a zigzag model are used in MD simulation. In each model, the motor with different diameters and rotational speeds is employed to examine the rotational transmission of corresponding DWCNTs. It is demonstrated that the long range van der Waals interaction between the adjacent ends of motor and rotor leads to a stable configuration of the adjacent ends, and further leads to a stable rotation of rotor when driven by a high-speed motor. As compared with the armchair model, the rotor in the zigzag model could reach a stable rotation mode much easier.

  13. Scalable Heuristics for Planning, Placement and Sizing of Flexible AC Transmission System Devices

    Energy Technology Data Exchange (ETDEWEB)

    Frolov, Vladmir [Skolkovo Institute of Science and Technology, Skolkovo (Russia); Backhaus, Scott N. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Chertkov, Michael [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-07-02

    Aiming to relieve transmission grid congestion and improve or extend feasibility domain of the operations, we build optimization heuristics, generalizing standard AC Optimal Power Flow (OPF), for placement and sizing of Flexible Alternating Current Transmission System (FACTS) devices of the Series Compensation (SC) and Static VAR Compensation (SVC) type. One use of these devices is in resolving the case when the AC OPF solution does not exist because of congestion. Another application is developing a long-term investment strategy for placement and sizing of the SC and SVC devices to reduce operational cost and improve power system operation. SC and SVC devices are represented by modification of the transmission line inductances and reactive power nodal corrections respectively. We find one placement and sizing of FACTs devices for multiple scenarios and optimal settings for each scenario simultaneously. Our solution of the nonlinear and nonconvex generalized AC-OPF consists of building a convergent sequence of convex optimizations containing only linear constraints and shows good computational scaling to larger systems. The approach is illustrated on single- and multi-scenario examples of the Matpower case-30 model.

  14. Interference Robust Transmission for the Downlink of an OFDM-Based Mobile Communications System

    Directory of Open Access Journals (Sweden)

    Markus Konrad

    2008-01-01

    Full Text Available Radio networks for future mobile communications systems, for example, 3GPP Long-Term Evolution (LTE, are likely to use an orthogonal frequency division multiplexing- (OFDM- based air interface in the downlink with a frequency reuse factor of one to avoid frequency planning. Therefore, system capacity is limited by interference, which is particularly crucial for mobile terminals with a single receive antenna. Nevertheless, next generation mobile communications systems aim at increasing downlink throughput. In this paper, a single antenna interference cancellation (SAIC algorithm is introduced for amplitude-shift keying (ASK modulation schemes in combination with bit-interleaved coded OFDM. By using such a transmission strategy, high gains in comparison to a conventional OFDM transmission with quadrature amplitude modulation (QAM can be achieved. The superior performance of the novel scheme is confirmed by an analytical bit-error probability (BEP analysis of the SAIC receiver for a single interferer, Rayleigh fading, and uncoded transmission. For the practically more relevant multiple interferer case we present an adaptive least-mean-square (LMS and an adaptive recursive least-squares (RLS SAIC algorithm. We show that in particular the RLS approach enables a good tradeoff between performance and complexity and is robust even to multiple interferers.

  15. Dosage Form Developments of Nanosuspension Drug Delivery System for Oral Administration Route.

    Science.gov (United States)

    Chen, Ang; Shi, Ye; Yan, Zhiqiang; Hao, Hongxun; Zhang, Yong; Zhong, Jian; Hou, Huiming

    2015-01-01

    A large amount of new drug candidates are practically insoluble in aqueous solvents and are even simultaneously poorly soluble in organic solvents. Nanosuspension drug delivery system (DDS) was firstly developed in 1994 and has attracted more and more attention as a formation solution for the poorly soluble drugs. By nansizing the poorly soluble drugs, nanosuspensions have several outstanding advantages for drug delivery. Among many administration routes of drug delivery, oral administration is the most preferred route due to its advantages such as ease of ingestion, versatility to accommodate various types of drug candidates, low production cost, high safety, good patient compliance, and pain avoidance. Current marketed pharmaceutical nanosuspension DDS products are mostly for oral administration. This review is to systematically summarize the nanosuspension DDS dosage form developments of poorly soluble drugs for oral administration use.

  16. Harmonic Resonance in Power Transmission Systems due to the Addition of Shunt Capacitors

    Science.gov (United States)

    Patil, Hardik U.

    Shunt capacitors are often added in transmission networks at suitable locations to improve the voltage profile. In this thesis, the transmission system in Arizona is considered as a test bed. Many shunt capacitors already exist in the Arizona transmission system and more are planned to be added. Addition of these shunt capacitors may create resonance conditions in response to harmonic voltages and currents. Such resonance, if it occurs, may create problematic issues in the system. It is main objective of this thesis to identify potential problematic effects that could occur after placing new shunt capacitors at selected buses in the Arizona network. Part of the objective is to create a systematic plan for avoidance of resonance issues. For this study, a method of capacitance scan is proposed. The bus admittance matrix is used as a model of the networked transmission system. The calculations on the admittance matrix were done using Matlab. The test bed is the actual transmission system in Arizona; however, for proprietary reasons, bus names are masked in the thesis copy intended for the public domain. The admittance matrix was obtained from data using the PowerWorld Simulator after equivalencing the 2016 summer peak load (planning case). The full Western Electricity Coordinating Council (WECC) system data were used. The equivalencing procedure retains only the Arizona portion of the WECC. The capacitor scan results for single capacitor placement and multiple capacitor placement cases are presented. Problematic cases are identified in the form of 'forbidden response. The harmonic voltage impact of known sources of harmonics, mainly large scale HVDC sources, is also presented. Specific key results for the study indicated include: (1) The forbidden zones obtained as per the IEEE 519 standard indicates the bus 10 to be the most problematic bus. (2) The forbidden zones also indicate that switching values for the switched shunt capacitor (if used) at bus 3 should be

  17. IBM i5iSeries Primer Concepts and Techniques for Programmers, Administrators, and System Operators

    CERN Document Server

    Forsythe, Kevin; Holt, Ted; Pence, Doug

    2012-01-01

    This comprehensive, 35-chapter book is the ultimate resource and a "must-have" for every professional working with the i5/iSeries. It is perfect for novice and intermediate programmers as well as for system administrators and operators. In simple, straightforward style, the authors explain core i5/iSeries concepts and show you step by step how to perform a wide variety of essential functions. The book includes sections on installation, operations, administration, system architecture, programming, the Internet, and troubleshooting. These sections are organized in free-standing style so you d

  18. ELECTRODYNAMICS OF TRANSMISSION AND LOSSES OF POWER IN THE DEVICES OF ELECTRIC TRACTION SYSTEMS

    Directory of Open Access Journals (Sweden)

    M. O. Kostin

    2014-01-01

    Full Text Available Purpose. Theoretical justification of the "field" approach (based on electromagnetic field to the transmission and losses of power in the devices of traction power supply systems and electric rolling stock. Methodology. The methods of electromagnetic field theory and, in particular, the theory and practice of electromagnetic energy transmission based on the concept of the Poynting vector and elements of the theory of propagation, reflection and refraction of plane electromagnetic waves were used. Findings. Theoretical studies of electromagnetic energy transmission from the traction substation to the electric rolling stock through dielectric (air surrounding traction network: between the contact wire and the rail were carried out. It is proposed strategic designing "squat" (low types of electric rolling stock. The components of electric energy flow through the roof of electric rolling stock and its frontal part of the body were estimated. This allows reliable etimating active power losses in electric traction system. To compensate the reactive power consumed by electric rolling stock, which is conditioned by standing waves, it is proposed (for extinction of the the last to develop and put in front of electric rolling stock the layer of particular environment with the necessary parameters. Originality. The "field" principle of the power transmission analysis and its losses arising in electric traction system was first proposed. The laws of motion of electromagnetic energy flows through the roof and the frontal part of the body of electric rolling stock were established. Practical value. An expression of the absolute value of the Poynting vector in the points of dielectric (air between the contact wire and the rail was obtained. This allows assessing the highest density of energy, which is transferred to the time unit and predicting the main dimensions of the unit of electric rolling stock. The energy indices of the roof of electric rolling stock

  19. A 60GHz RoF(radio-over-fiber) transmission system based on PM modulator

    Science.gov (United States)

    Wang, Xin; Liu, Yi; Wang, Wen-Ting

    2016-11-01

    As one of the most important applications of microwave photonic ROF (Radio over Fiber) system which combines the advantages of optical communication and wireless communication is a good candidate for broadband mobile Communication In this paper, we built and simulation a 60GHz RoF(Radio-over-Fiber) transmission system based on PM modulator. First, we introduce the PM-IM(Phase modulation to intensity modulation) modulation mechanisms by the breaking the phase balanced approach. This method solves the problem that the constant envelope (phase modulation signal) generated by the phase modulator can not be directly detected by a photo detector. A standard single-mode fiber (SMF) is connected input to the F-P(Fabry-Perot) optical filter, which is to achieve the PM-IM modulation conversion by changing the wavelength of the laser or the frequency of the modulation factor of the F-P optical filter to adapt to different fiber lengths and the signal transmission rate. These two methods which changing the phase relationship between the optical carrier and the optical side band can realize the ideal phase transition to obtain efficient and low loss modulation conversion. Finally, the simulation results show that different fiber lengths and the signal transmission rate configuration of different wavelength of the laser or the frequency of the modulation factor of the F-P optical filter, the BER performance and the eye diagram of the 60GHz RoF transmission system signals have been improved based on these PM-IM modulation methods.

  20. Independent transmission system operators and their role in maintaining reliability in a restructured electric power industry

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-01-01

    This report summarizes the current status of proposals to form Independent System Operators (ISOs) to operate high-voltage transmission systems in the United States and reviews their potential role in maintaining bulk power system reliability. As background information, the likely new industry structure, nature of deregulated markets, and institutional framework for bulk power system reliability are reviewed. The report identifies issues related to the formation of ISOs and their roles in markets and in reliability, and describes potential policy directions for encouraging the formation of effective ISOs and ensuring bulk system reliability. Two appendices are provided, which address: (1) system operation arrangements in other countries, and (2) summaries of regional U.S. ISO proposals.

  1. Stability analysis of transmission system with high penetration of distributed generation

    Energy Technology Data Exchange (ETDEWEB)

    Reza, M.

    2006-12-21

    Nowadays, interest in generating electricity using decentralized generators of relatively small scale ('distributed generation', DG) is increasing. This work deals with the impact of implementing DG on the transmission system transient stability, with the emphasis on a potential transition from a 'vertical power system' to a 'horizontal power system. A problem in power systems is maintaining synchronous operation of all (centralized) synchronous machines. This stability problem associated is called rotor angle stability. In this work, the impact of the DG implementation on this is investigated. The impact of DG levels on the system transient stability when the increasing DG level is followed by a reduction of centralized generators in service resulting in a 'vertical to horizontal' transformation of the power system is also investigated. Furthermore, a stochastic analysis is used to study the transient stability of the power systems. The results show that including the stochastic behavior of DG leads to a more complete and detailed view of the system performance. Finally, the situation when the power system is pushed towards a scenario, where DG penetration reaches a level that covers the total load of the original power system (100% DG level) is investigated. The research performed in this work indicates that from the transmission system stability point of view, if higher DG penetration levels are coming up, sufficient inertia and voltage support must be installed. Furthermore, one should be aware of the fact that the system behaves stochastically, especially with DG. To a certain extent regional balancing of power can be performed by local voltage control.

  2. Analysis of operations and cyber security policies for a system of cooperating Flexible Alternating Current Transmission System (FACTS) devices.

    Energy Technology Data Exchange (ETDEWEB)

    Phillips, Laurence R.; Tejani, Bankim; Margulies, Jonathan; Hills, Jason L.; Richardson, Bryan T.; Baca, Micheal J.; Weiland, Laura

    2005-12-01

    Flexible Alternating Current Transmission Systems (FACTS) devices are installed on electric power transmission lines to stabilize and regulate power flow. Power lines protected by FACTS devices can increase power flow and better respond to contingencies. The University of Missouri Rolla (UMR) is currently working on a multi-year project to examine the potential use of multiple FACTS devices distributed over a large power system region in a cooperative arrangement in which the FACTS devices work together to optimize and stabilize the regional power system. The report describes operational and security challenges that need to be addressed to employ FACTS devices in this way and recommends references, processes, technologies, and policies to address these challenges.

  3. Application of Wireless Power Transmission Systems in Wireless Capsule Endoscopy: An Overview

    Directory of Open Access Journals (Sweden)

    Md Rubel Basar

    2014-06-01

    Full Text Available Wireless capsule endoscopy (WCE is a promising technology for direct diagnosis of the entire small bowel to detect lethal diseases, including cancer and obscure gastrointestinal bleeding (OGIB. To improve the quality of diagnosis, some vital specifications of WCE such as image resolution, frame rate and working time need to be improved. Additionally, future multi-functioning robotic capsule endoscopy (RCE units may utilize advanced features such as active system control over capsule motion, drug delivery systems, semi-surgical tools and biopsy. However, the inclusion of the above advanced features demands additional power that make conventional power source methods impractical. In this regards, wireless power transmission (WPT system has received attention among researchers to overcome this problem. Systematic reviews on techniques of using WPT for WCE are limited, especially when involving the recent technological advancements. This paper aims to fill that gap by providing a systematic review with emphasis on the aspects related to the amount of transmitted power, the power transmission efficiency, the system stability and patient safety. It is noted that, thus far the development of WPT system for this WCE application is still in initial stage and there is room for improvements, especially involving system efficiency, stability, and the patient safety aspects.

  4. The Cost and Benefit of Bulk Energy Storage in the Arizona Power Transmission System

    Science.gov (United States)

    Ruggiero, John

    This thesis addresses the issue of making an economic case for energy storage in power systems. Bulk energy storage has often been suggested for large scale electric power systems in order to levelize load; store energy when it is inexpensive and discharge energy when it is expensive; potentially defer transmission and generation expansion; and provide for generation reserve margins. As renewable energy resource penetration increases, the uncertainty and variability of wind and solar may be alleviated by bulk energy storage technologies. The quadratic programming function in MATLAB is used to simulate an economic dispatch that includes energy storage. A program is created that utilizes quadratic programming to analyze various cases using a 2010 summer peak load from the Arizona transmission system, part of the Western Electricity Coordinating Council (WECC). The MATLAB program is used first to test the Arizona test bed with a low level of energy storage to study how the storage power limit effects several optimization out-puts such as the system wide operating costs. Very high levels of energy storage are then added to see how high level energy storage affects peak shaving, load factor, and other system applications. Finally, various constraint relaxations are made to analyze why the applications tested eventually approach a constant value. This research illustrates the use of energy storage which helps minimize the system wide generator operating cost by "shaving" energy off of the peak demand.

  5. Application of wireless power transmission systems in wireless capsule endoscopy: an overview.

    Science.gov (United States)

    Basar, Md Rubel; Ahmad, Mohd Yazed; Cho, Jongman; Ibrahim, Fatimah

    2014-06-19

    Wireless capsule endoscopy (WCE) is a promising technology for direct diagnosis of the entire small bowel to detect lethal diseases, including cancer and obscure gastrointestinal bleeding (OGIB). To improve the quality of diagnosis, some vital specifications of WCE such as image resolution, frame rate and working time need to be improved. Additionally, future multi-functioning robotic capsule endoscopy (RCE) units may utilize advanced features such as active system control over capsule motion, drug delivery systems, semi-surgical tools and biopsy. However, the inclusion of the above advanced features demands additional power that make conventional power source methods impractical. In this regards, wireless power transmission (WPT) system has received attention among researchers to overcome this problem. Systematic reviews on techniques of using WPT for WCE are limited, especially when involving the recent technological advancements. This paper aims to fill that gap by providing a systematic review with emphasis on the aspects related to the amount of transmitted power, the power transmission efficiency, the system stability and patient safety. It is noted that, thus far the development of WPT system for this WCE application is still in initial stage and there is room for improvements, especially involving system efficiency, stability, and the patient safety aspects.

  6. Modeling the Impacts of Geomagnetic Disturbances on the New York State Power Transmission System

    Science.gov (United States)

    Ouedraogo, D.; Castillo, O. L.; Mohamed, A.; Damas, M. C.; Ngwira, C. M.

    2015-12-01

    Our society today relies heavily on electricity in order to meet its essential basic needs. However, to meet the rising demands for this energy, all power companies require smooth and efficient delivery of services to the consumers. The US power grid is a complex electrical apparatus that has well known sensitivities to space weather disturbances. Events produced by space weather includes solar storms or geomagnetic disturbances [GMD]. The propagation of such events in the direction of Earth perturbs the electric currents in the magnetosphere and the ionosphere, causing a unique effect known as a Geomagnetically Induced Current [GIC]. GICs are known to saturate and overheat transformers in the power grid, threatening the safe operation of the power system. A GMD induces a geoelectric field in high-voltage and extra high-voltage transmission circuits. This geoelectric field represents electromotive force, and causes GICs to circulate through transmission circuits and transformers. Power models are being developed using MATLAB/Simulink® software to simulate the propagation of GIC flows in a power system, while using New York State (NYS) power transmission network as an example. We will present results of the models used to assess the impacts of possible GMD strikes on the various parts of the power network.

  7. Onshore continuation of bipolar cable systems for bulk wind power transmission

    Energy Technology Data Exchange (ETDEWEB)

    Brakelmann, Heinrich; Brueggmann, Jan; Stammen, Joerg [Duisburg-Essen Univ., Duisburg (Germany). Dept. of Electrical Engineering

    2009-07-01

    Offshore windfarms have to be connected to the onshore grid by means of high voltage submarine cables. Typical windfarms (pilot-phase) may have an installed power of 400 MW. Several windfarms can be arranged to a cluster with a common grid connection which has to be designed for e.g. 2000 MW. For such tasks of bulk power transmission, the HVAC bipolar cable system was proposed. By use of three 245 kV bipolar four-core submarine cables, the desired 2000 MW can be transmitted over distances of more than 150 km. Hence, HVAC bipolar systems offer an efficient bulk power transmission with flexibility in installation and operation. Onshore, such connections have to find a continuation by use of land cables. In order to enable extreme transmission capacities, cable routes are analysed, which are equipped with standard 245 kV single-core XLPE-cables in bipolar configurations and with special, thermally improved backfill. Time varying loads and partially dried-out soil are considered. (orig.)

  8. A social-based cyber-physical system for distributed message transmission

    Science.gov (United States)

    Chen, Kang; Shen, Haiying

    2014-06-01

    The explosive increase of the availability of personal mobile devices has brought about a significant amount of peer-to-peer communication opportunities upon their encountering, which can be exploited to realize distributed message transmission among mobile devices. However, the opportunistic encountering among mobile devices, which is determined by the mobility of their holders, has introduced great difficulties on efficiently transmitting a message to its designated destination. Actually, people usually present a certain pattern on daily mobility. Further, device holders often belong to a certain social network community. Therefore, in this paper, we propose a social- based cyber-physical system for distributed message transmission, namely SocMessaging, by integrating both the mobility pattern and the social network of device holders. When selecting an encountered node for message relay, in addition to the node's historical encountering records with the destination node, SocMessaging also considers its social closeness with the destination node. Then, the message is always transmitted to the node that is most likely to meet its destination. As a result, SocMessaging closely connects the cyber world (i.e., network), physical world (i.e., people) and social network (i.e., social connection). Finally, our experimental results demonstrate the efficiency of the proposed system in message transmission between device holders.

  9. Information-transmission rates in manual control of unstable systems with time delays.

    Science.gov (United States)

    Lupu, Mircea F; Sun, Mingui; Wang, Fei-Yue; Mao, Zhi-Hong

    2015-01-01

    In analyzing the human-machine interaction (HMI), a human-centered approach is needed to address the potential and limitation of human control, especially in the control of high-order or unstable systems. However, there is no quantitative measure of the human performance or cognitive workload in these difficult HMI tasks. We propose to characterize the HMI as information flows quantified by the information-transmission rate in bits per second (b/s). Using information- and control-theoretic approaches, we derive the minimum rates of information transmission in manual control required by any deterministic controller to stabilize the feedback system. Furthermore, we suggest a method adopted from time-series analysis to estimate the information-transmission rate from human experiments. We show that the relationship between the empirically estimated information rates and the minimum bounds allows for the quantitative indication of the potential and limitation of human manual control. We illustrate our method in the control of an inverted pendulum with time delays.

  10. Natural Gas Transmission and Distribution Model of the National Energy Modeling System. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-01-01

    The Natural Gas Transmission and Distribution Model (NGTDM) is the component of the National Energy Modeling System (NEMS) that is used to represent the domestic natural gas transmission and distribution system. The NGTDM is the model within the NEMS that represents the transmission, distribution, and pricing of natural gas. The model also includes representations of the end-use demand for natural gas, the production of domestic natural gas, and the availability of natural gas traded on the international market based on information received from other NEMS models. The NGTDM determines the flow of natural gas in an aggregate, domestic pipeline network, connecting domestic and foreign supply regions with 12 demand regions. The purpose of this report is to provide a reference document for model analysts, users, and the public that defines the objectives of the model, describes its basic design, provides detail on the methodology employed, and describes the model inputs, outputs, and key assumptions. Subsequent chapters of this report provide: an overview of NGTDM; a description of the interface between the NEMS and NGTDM; an overview of the solution methodology of the NGTDM; the solution methodology for the Annual Flow Module; the solution methodology for the Distributor Tariff Module; the solution methodology for the Capacity Expansion Module; the solution methodology for the Pipeline Tariff Module; and a description of model assumptions, inputs, and outputs.

  11. Enhancing power transfer capability through flexible AC transmission system devices:a review

    Institute of Scientific and Technical Information of China (English)

    Fadi M ALBATSH; Saad MEKHILEF; Shameem AHMAD; H MOKHLIS; M A HASSAN

    2015-01-01

    Global demand for power has significantly increased, but power generation and transmission capacities have not increased proportionally with this demand. As a result, power consumers suffer from various problems, such as voltage and frequency instability and power quality issues. To overcome these problems, the capacity for available power transfer of a transmission network should be enhanced. Researchers worldwide have addressed this issue by using flexible AC transmission system (FACTS) devices. We have conducted a comprehensive review of how FACTS controllers are used to enhance the avail-able transfer capability (ATC) and power transfer capability (PTC) of power system networks. This review includes a discussion of the classification of different FACTS devices according to different factors. The popularity and applications of these devices are discussed together with relevant statistics. The operating principles of six major FACTS devices and their application in increasing ATC and PTC are also presented. Finally, we evaluate the performance of FACTS devices in ATC and PTC im-provement with respect to different control algorithms.

  12. Prospective application of advanced series compensation to improve transmission system performance

    Energy Technology Data Exchange (ETDEWEB)

    Gama, C.A.; Scavassa, J.L.; Silva, W.M. da; Silva, J.M.M. da; Ponte, J.R. [ELETRONORTE, Brasilia, DF (Brazil)

    1994-12-31

    This paper describes the main aspects and results of the planning studies undertaken to evaluate the technical benefits of using Thyristor Controlled Series Compensation (TCSC), in a large 500 kV transmission system (Brazilian North-Northeast system). TCSC controllers design and simplified models for digital non-linear time domain simulations are discussed. The proposed controllers are tuned and used to support the comparative analysis between controlled and fixed series compensation. The relevant conclusions concerning this comparison are highlighted. (author) 2 refs., 14 figs., 3 tabs.

  13. The European Legislation Applicable to Medium-Range Inductive Wireless Power Transmission Systems

    Directory of Open Access Journals (Sweden)

    Frédéric Broydé

    2014-01-01

    Full Text Available Medium-range inductive wireless power transmission systems allow a sufficient power transfer without requiring close proximity between a primary coil and a secondary coil. We briefly investigate the range of a typical system and its radiated emission, from the perspectives of electromagnetic compatibility (EMC and human exposure requirements. We then discuss the applicable legislation in the European Union, the main question being the applicability of the R&TTE or radio equipment directives. Our conclusion is that this applicability depends on multiple parameters, among which is the presence of a self-tuning capability or of a transmitter control based on telemetry.

  14. LogAmp electronics and optical transmission for the new SPS beam position measurement system

    Science.gov (United States)

    Bogey, T.; Deplano, C.; Gonzalez, J. L.; Savioz, J. J.

    2013-12-01

    A new front-end board is under development for the CERN SPS Multi ORbit Position System (MOPOS). Based on logarithmic amplifiers, it measures the beam position over a large dynamic range of beam intensities and resolves the multi-batch structure of the SPS beams. Analogue data are digitized at 10 MS/s, packed in frames by an FPGA and on every turn sent to the readout board, via a 2.4 Gb/s optical transmission link. A first prototype has been successfully tested with several SPS beams. This paper presents an overall description of the system and its capabilities highlighted by the first beam measurements.

  15. LogAmp electronics and Optical Transmission for the new SPS Beam Position Measurement System

    CERN Document Server

    Deplano, C; Gonzalez, J L; Savioz, J J

    2013-01-01

    A new front-end board is under development for the CERN SPS Multi ORbit Position System (MOPOS). Based on logarithmic amplifiers, it measures the beam position over a large dynamic range of beam intensities and resolves the multi-batch structure of the SPS beams. Analogue data are digitized at 10 MS/s, packed in frames by an FPGA and on every turn sent to the readout board, via a 2.4 Gb/s optical transmission link. A first prototype has been successfully tested with several SPS beams. This paper presents an overall description of the system and its capabilities highlighted by the first beam measurements.

  16. Effect of bulk modulus on performance of a hydrostatic transmission control system

    Indian Academy of Sciences (India)

    Ali Volkan Akkaya

    2006-10-01

    In this paper, we examine the performance of PID (proportional integral derivative) and fuzzy controllers on the angular velocity of a hydrostatic transmission system by means of Matlab-Simulink. A very novel aspect is that it includes the analysis of the effect of bulk modulus on system control. Simulation results demonstrates that bulk modulus should be considered as a variable parameter to obtain a more realistic model. Additionally, a PID controller is insufficient in presence of variable bulk modulus, whereas a fuzzy controller provides robust angular velocity control.

  17. A Horn-to-Horn Power Transmission System at Terahertz Frequencies

    Science.gov (United States)

    Gonzalez, A.; Uzawa, Y.; Fujii, Y.; Kaneko, K.; Kuroiwa, K.

    2011-11-01

    A horn-to-horn power transmission system at Terahertz frequencies has been designed and tested. Power is generated at microwave frequencies and then frequency multiplied to the band 799-938 GHz. The resultant signal is radiated by a diagonal horn and redirected by two identical elliptical mirrors to another diagonal horn located far away. Useful design equations have been derived for the proposed system. The concept has been proven by careful measurements and utilized for the local oscillator injection in the Atacama Large Millimeter Array (ALMA) Band-10 receiver.

  18. An Initial Topology of Multi-terminal HVDC Transmission System in Europe

    DEFF Research Database (Denmark)

    Irnawan, Roni; Silva, Filipe Miguel Faria da; Bak, Claus Leth;

    2016-01-01

    In this paper, technical challenges for realizing offshore multi-terminal HVDC (MTDC) transmission system in Europe is evaluated. An offshore MTDC topology is projected by interconnecting point-to-point HVDC links with the same voltage level and technology found in south-eastern part of North Sea....... Availability analysis is done to evaluate the feasibility of the proposed offshore MTDC topology. As compared to point-to-point (PtP) HVDC link, MTDC operation gives a more secure and reliable system. This paper shows that the proposed MTDC topology can operate 98.36% of the time....

  19. Route-asymmetrical light transmission of a fiber-chip-fiber optomechanical system

    DEFF Research Database (Denmark)

    Liu, Li; Ding, Yunhong; Cai, Xinlun;

    2016-01-01

    In this paper, we proposed and experimentally demonstrated a route-asymmetrical light transmission scheme based on the thermal radiative effect, which means that forward and backward propagations of an optical device have different transmittances provided they are not present simultaneously......-wave (CW) light but also 10 Gbit/s on-off-keying (OOK) digital signals. Above mentioned unique features can be mostly attributed to the significant characteristics of the thermal radiative effect, which could cause a fiber displacement up to tens of microns. The powerful and significant thermal radiative...... effect opens up a new opportunity and method for route-asymmetrical light transmission. Moreover, this research may have important applications in all-optical systems, such as the optical limiters and ultra-low loss switches....

  20. Transmission line design for a power distribution system at 20 kHz for aircraft

    Science.gov (United States)

    Zelby, L. W.; Mathes, J. B.; Shawver, J. W.

    1986-01-01

    A low inductance, low characteristic impedance transmission line was designed for a 20 kHz power distribution system. Several different conductor configurations were considered: strip lines, interdigitated metal ribbons, and standard insulated wires in multiwire configurations (circular and rectangular cylindrical arrangements). The final design was a rectangular arrangement of multiple wires of the same gauge with alternating polarities from wire to wire. This offered the lowest inductance per unit length (on the order of several nanohenries/meter) and the lowest characteristic impedance (on the order of one Ohm). Standard multipin connectors with gold-plated elements were recommended with this transmission line, the junction boxes to be internally connected with flat metal ribbons for low inductance, and the line to be constructed in sections of suitable length. Computer programs for the calculation of inductance of multiwire lines and of capacitances of strip lines were developed.