WorldWideScience

Sample records for adjacent vessel sign

  1. Significance of 'Bridging vessel sign' on color Doppler ultrasound in diagnosis of uterine subserosal leiomyoma

    International Nuclear Information System (INIS)

    Lee, Jin Hee; Lee, Jung Hee; Sohn, Chul Ho; Woo, Seung Koo; Kim, Jung Sik

    2002-01-01

    To evaluate the usefulness of the 'bridging vessel sign' in differentiating uterine subserosal leiomyoma from other pelvic masses mimicking leiomyoma on color Doppler ultrasound. Histologically (n=58) and clinically (n=1) proven 59 masses from 55 women were included in this study. Histologic diagnoses included leiomyoma (n=32) and various kinds of other masses (n=27). On gray scale ultrasound, the size of tumor and presence of the ovaries were recorded. On color Doppler ultrasound, the presence of 'bridging vessel sign', which was defined as a linear vessel demonstrated between the mass and the uterus was documented. Uterine subserosal leiomyoma was diagnosed on the basis of finding this sign, and the diagnostic accuracy of this sign in differentiating subserosal leiomyoma from other pelvic tumors was calculated. In addition, the diagnostic accuracy of this sign combined with the visibility of theopsilateral ovary was compared. The size of subserosal leiomyomas ranged from 4.2 to 22.1 cm (mean, 8.3 cm) while the size of other pelvic masses, from 4.6 to 21.5 cm (mean, 9.6 cm). The 'bridging vessel sign' was demonstrated in thirty of 32 leiomyomas and in three of 27 other pelvis masses. The sensitivity, specificity, accuracy, positive predictive value, and negative value of the 'bridging vessel sign' in the diagnosis of subserosal leiomyoma were 93.8%, 99.9%, 91.5%, 90.9% and 92.3%, respectively. The detection of the ipsilateral ovary was possible in 14 of 30 women with leiomyomas and in four of 25 women with other pelvic masses. The sensitivity, specificity, accuracy, positive predictive value and negative predictive value of this finding in the diagnosis of subserosal leiomyoma were 46.7%, 84.0%, 63.6%, 77.8%, and 56.8%, respectively. 'Bridging vessel sign' can be an useful finding in the differential diagnosis of subserosal leiomyomas from other pelvic masses mimicking leiomyoma.

  2. 75 FR 13654 - Use of Foreign-Flag Anchor Handling Vessels in the Beaufort Sea or Chukchi Sea Adjacent to Alaska

    Science.gov (United States)

    2010-03-22

    ... submitted by hand or by mail to the Docket Clerk, U.S. DOT Dockets, Room PL-401, Department of... handling vessel adjacent to the coast of Alaska. The foreign-flag anchor handling vessel (TOR VIKING...

  3. Significance of 'Bridging vessel sign' on color Doppler ultrasound in diagnosis of uterine subserosal leiomyoma

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jin Hee; Lee, Jung Hee; Sohn, Chul Ho; Woo, Seung Koo [Keimyung University School of Medicine, Taegu (Korea, Republic of); Kim, Jung Sik [Radiological Clinic, Taegu (Korea, Republic of)

    2002-06-15

    To evaluate the usefulness of the 'bridging vessel sign' in differentiating uterine subserosal leiomyoma from other pelvic masses mimicking leiomyoma on color Doppler ultrasound. Histologically (n=58) and clinically (n=1) proven 59 masses from 55 women were included in this study. Histologic diagnoses included leiomyoma (n=32) and various kinds of other masses (n=27). On gray scale ultrasound, the size of tumor and presence of the ovaries were recorded. On color Doppler ultrasound, the presence of 'bridging vessel sign', which was defined as a linear vessel demonstrated between the mass and the uterus was documented. Uterine subserosal leiomyoma was diagnosed on the basis of finding this sign, and the diagnostic accuracy of this sign in differentiating subserosal leiomyoma from other pelvic tumors was calculated. In addition, the diagnostic accuracy of this sign combined with the visibility of theopsilateral ovary was compared. The size of subserosal leiomyomas ranged from 4.2 to 22.1 cm (mean, 8.3 cm) while the size of other pelvic masses, from 4.6 to 21.5 cm (mean, 9.6 cm). The 'bridging vessel sign' was demonstrated in thirty of 32 leiomyomas and in three of 27 other pelvis masses. The sensitivity, specificity, accuracy, positive predictive value, and negative value of the 'bridging vessel sign' in the diagnosis of subserosal leiomyoma were 93.8%, 99.9%, 91.5%, 90.9% and 92.3%, respectively. The detection of the ipsilateral ovary was possible in 14 of 30 women with leiomyomas and in four of 25 women with other pelvic masses. The sensitivity, specificity, accuracy, positive predictive value and negative predictive value of this finding in the diagnosis of subserosal leiomyoma were 46.7%, 84.0%, 63.6%, 77.8%, and 56.8%, respectively. 'Bridging vessel sign' can be an useful finding in the differential diagnosis of subserosal leiomyomas from other pelvic masses mimicking leiomyoma.

  4. Quantitative evaluation in enhancement of pancreas and adjacent vessels during spiral CT

    International Nuclear Information System (INIS)

    Kim, Hyoung Seuk; Shin, Kue Hee; Park, Cheol Min; Cha, Sang Hoon; Chung, Kyoo Byung

    1997-01-01

    To determine by quantitative evaluation of pancreatic and adjacent vascular enhancement during spiral CT, the ideal scan delay for examination of the pancreas. Dual(n=3D90) and triple(n=3D90) phase spiral CT scans of patients whose pancreas showed no pathologic condition were retrospectively evaluated. Dual-phase scans were performed at 43 seconds(early), and 5-6 minutes(delayed) after the injection of 120ml of contrast material at an injection rate of 3ml/sec;triple-phase scans were performed at 25 seconds(arterial),60-65 seconds (portal) and 5-6 minutes (delayed) after the injection of 120-140ml of contrast material at an injection rate of 2-4ml/sec, and ten patients also underwent precontrast scanning. CT attenuation values(HU) were measured in the head, body and tail of the pancreas, aorta, and main portal vein during each phase of all scans. Triple-phase protocol was used to measure the effect of different total volumes and injection rates on enhancement of the pancreas and adjacent vessels. There was no significant difference in the degree of enhancement of the pancreas head, body and tail during each phase(p>0.05). The pancreas was maximally enhanced on 43 second delayed scan(132±20HU)(p 0.05). The main portal vein showed maximum enhancement on 43-second delayed scan(207±44HU)(p<0.05). Different total volume of contrast material did not change the enhancement of the pancreas and adjacent vessels. At an injection rate of 2ml/sec, peak enhancement of the pancreas, aorta and portal vein was obtained on 60-65 second delayed scan, and at 4ml/sec, peak enhancement was obtained on 25 second delayed scan(p<0.05). Observing the usual protocols for abdominal spiral CT scanning, the pancreas was most effectively evaluated using a 43-second delayed scan. An increased injection rate resulted in earlier enhancement of the pancreas, aorta and portal vein

  5. 33 CFR 165.1317 - Security and Safety Zone; Large Passenger Vessel Protection, Puget Sound and adjacent waters...

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Security and Safety Zone; Large Passenger Vessel Protection, Puget Sound and adjacent waters, Washington. 165.1317 Section 165.1317 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PORTS AND WATERWAYS...

  6. Blurring of the vessels of the interhemispheric fissure in multislice CT angiography: a sign of meningeal carcinomatosis

    International Nuclear Information System (INIS)

    Ertl-Wagner, Birgit B.; Hoffmann, Ralf-Thorsten; Herrmann, Karin; Reiser, Maximilian F.; Bruening, Roland; Dichgans, Martin

    2004-01-01

    Meningeal carcinomatosis remains a challenging diagnosis to make, with both cerebrospinal fluid (CSF) analysis and radiological methods having a limited sensitivity. We aimed at describing a possible diagnostic sign of multislice CT angiography (MS-CTA) in the diagnosis of meningeal carcinomatosis. Upon retrospective analysis of MSCT angiographies of the brain, a conspicuous sign of the vessels of the interhemispheric fissure was noted in five patients. Cranial MSCT angiographies were performed with a standardized protocol (120 kV, 200 mA s, collimation of 4 x 1 mm, table feed per rotation 4 mm). We injected 120 ml of nonionic contrast medium as a bolus, and data acquisition was started after a fixed delay of 35 s. In order to elucidate the finding, correlation with clinical follow-up and/or CSF findings was performed for all patients. In five patients there was a blurring, an increased number, and a pathologic configuration of the vessels of the interhemispheric fissure. All five patients with this sign had clinical signs and symptoms of meningeal carcinomatosis. Three patients had positive CSF cytology, one further patient had follow-up spinal MRI 6 weeks later demonstrating meningeal carcinomatosis. One patient declined lumbar puncture. MS-CTA has the capacity to demonstrate a pathologic configuration of the vessels of the interhemispheric fissure in patients with meningeal carcinomatosis. This sign may serve as an indicator of meningeal carcinomatosis and should raise the suspicion of this disease entity. (orig.)

  7. Treatment of hepatocellular carcinoma adjacent to large blood vessels using 1.5T MRI-guided percutaneous radiofrequency ablation combined with iodine-125 radioactive seed implantation

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Zheng-Yu, E-mail: linsinlan@yahoo.com.cn [The Department of Radiology, First Affiliated Hospital of Fujian Medical University, 20 Chazhong Road, Fuzhou 350005 (China); Chen, Jin, E-mail: snow8968851@163.com [The Department of Radiology, First Affiliated Hospital of Fujian Medical University, 20 Chazhong Road, Fuzhou 350005 (China); Deng, Xiu-Fen, E-mail: dxf197286@yahoo.com.cn [The Department of Radiology, First Affiliated Hospital of Fujian Medical University, 20 Chazhong Road, Fuzhou 350005 (China)

    2012-11-15

    Objective: The objective is to study the technology associated with and feasibility of the treatment of hepatocellular carcinoma (HCC) adjacent to large blood vessels using 1.5T MRI-guided radiofrequency ablation combined with iodine-125 (I-125) radioactive seed implantation. Methods: Sixteen patients with a total of 24 HCC lesions (average maximum diameter: 2.35 {+-} 1.03 cm) were pathologically confirmed by biopsy or clinically diagnosed received 1.5T MRI-guided percutaneous radiofrequency ablation (RFA) treatment. Each patient had one lesion adjacent to large blood vessels ({>=}3 mm); after the ablation, I-125 radioactive seeds were implanted in the portions of the lesions that were adjacent to the blood vessels. Results: All the ablations and I-125 radioactive seed implantations were successful; a total of 118 seeds were implanted. The ablated lesions exhibited hypointense signals on the T2WI sequence with a thin rim of hyperintense signals; they also exhibited significant hyperintense signals on the T1WI sequence with clear boundaries. The average follow-up period was 11.1 {+-} 6.2 months. There were 23 complete responses and one partial response in the 24 lesions. The alpha-fetoprotein (AFP) levels of the patients significantly decreased. Conclusion: The 1.5T MRI-guided RFA combined with I-125 radioactive seed implantation for the treatment of HCC adjacent to large blood vessels is an effective technology.

  8. World cup soccer players tend to be born with sun and moon in adjacent zodiacal signs

    Science.gov (United States)

    Verhulst, J

    2000-01-01

    The ecliptic elongation of the moon with respect to the sun does not show uniform distribution on the birth dates of the 704 soccer players selected for the 1998 World Cup. However, a uniform distribution is expected on astronomical grounds. The World Cup players show a very pronounced tendency (p = 0.00001) to be born on days when the sun and moon are in adjacent zodiacal signs. Key Words: soccer; World Cup; astrology; moon PMID:11131239

  9. Evaluation of the relationship between extremity soft tissue sarcomas and adjacent major vessels using contrast-enhanced multidetector CT and three-dimensional volume-rendered CT angiography - A preliminary study

    International Nuclear Information System (INIS)

    Li, YangKang; Lin, JianBang; Cai, AiQun; Zhou, XiuGuo; Zheng, Yu; Wei, XiaoLong; Cheng, Ying; Liu, GuoRui

    2013-01-01

    Background: Accurate description of the relationship between extremity soft tissue sarcoma and the adjacent major vessels is crucial for successful surgery. In addition to magnetic resonance imaging (MRI) or in patients who cannot undergo MRI, two-dimensional (2D) postcontrast computed tomography (CT) images and three-dimensional (3D) volume-rendered CT angiography may be valuable alternative imaging techniques for preoperative evaluation of extremity sarcomas. Purpose: To preoperatively assess extremity sarcomas using multidetector CT (MDCT), with emphasis on postcontrast MDCT images and 3D volume-rendered MDCT angiography in evaluating the relationship between tumors and adjacent major vessels. Material and Methods: MDCT examinations were performed on 13 patients with non-metastatic extremity sarcomas. Conventional CT images and 3D volume-rendered CT angiography were evaluated, with focus on the relationship between tumors and adjacent major vessels. Kappa consistency statistics were performed with surgery serving as the reference standard. Results: The relationship between sarcomas and adjacent vessels was described as one of three patterns: proximity, adhesion, and encasement. Proximity was seen in five cases on postcontrast CT images or in eight cases on volume-rendered images. Adhesion was seen in three cases on both postcontrast CT images and volume-rendered images. Encasement was seen in five cases on postcontrast CT images or in two cases on volume-rendered images. Compared to surgical results, postcontrast CT images had 100% sensitivity, 83.3% specificity, 87.5% positive predictive value, 100% negative predictive value, and 92.3% accuracy in the detection of vascular invasion (κ = 0.843, P = 0.002). 3D volume-rendered CT angiography had 71.4% sensitivity, 100% specificity, 100% positive predictive value, 75% negative predictive value, and 84.6% accuracy in the detection of vascular invasion (κ = 0.698, P = 0.008). On volume-rendered images, all cases

  10. Objectifying the adjacent and opposite angles: a cultural historical analysis

    Science.gov (United States)

    Daher, Wajeeh; Musallam, Nadera

    2018-02-01

    The angle topic is central to the development of geometric knowledge. Two of the basic concepts associated with this topic are the adjacent and opposite angles. It is the goal of the present study to analyze, based on the cultural historical semiotics framework, how high-achieving seventh grade students objectify the adjacent and opposite angles' concepts. We videoed the learning of a group of three high-achieving students who used technology, specifically GeoGebra, to explore geometric relations related to the adjacent and opposite angles' concepts. To analyze students' objectification of these concepts, we used the categories of objectification of knowledge (attention and awareness) and the categories of generalization (factual, contextual and symbolic), developed by Radford. The research results indicate that teacher's and students' verbal and visual signs, together with the software dynamic tools, mediated the students' objectification of the adjacent and opposite angles' concepts. Specifically, eye and gestures perceiving were part of the semiosis cycles in which the participating students were engaged and which related to the mathematical signs that signified the adjacent and the opposite angles. Moreover, the teacher's suggestions/requests/questions included/suggested semiotic signs/tools, including verbal signs that helped the students pay attention, be aware of and objectify the adjacent and opposite angles' concepts.

  11. Radiological signs pointing to altered correlations between heart and major vessels, esophagus and trachea

    International Nuclear Information System (INIS)

    Frantsov, S.

    1993-01-01

    A number of rather frequently encountered varieties and anomalies, involving heart and major vessels, esophagus, trachea, lungs and their X-ray images, are outlined. The study rests on rich experience with X-ray diagnosis of congenital cardiovascular malformations and acquired heart defects, and considers their complexity and difficult differential diagnosis. The radiological signs and diagnostic algorithm of examination are described, followed by a discussion of the differential diagnosis. The author's experience is based on X-ray diagnosis verified during operation. 9 refs., 1 fig. (orig.)

  12. SIGNS The sandwich sign

    African Journals Online (AJOL)

    The sandwich sign is demonstrated on cross-sectional imaging, commonly on CT or ultrasound. It refers to homogeneous soft- tissue masses representing mesenteric lymphadenopathy as the two halves of a sandwich bun, encasing the mesenteric fat and tubular mesenteric vessels that constitute the 'sandwich filling' (Figs ...

  13. An automated vessel segmentation of retinal images using multiscale vesselness

    International Nuclear Information System (INIS)

    Ben Abdallah, M.; Malek, J.; Tourki, R.; Krissian, K.

    2011-01-01

    The ocular fundus image can provide information on pathological changes caused by local ocular diseases and early signs of certain systemic diseases, such as diabetes and hypertension. Automated analysis and interpretation of fundus images has become a necessary and important diagnostic procedure in ophthalmology. The extraction of blood vessels from retinal images is an important and challenging task in medical analysis and diagnosis. In this paper, we introduce an implementation of the anisotropic diffusion which allows reducing the noise and better preserving small structures like vessels in 2D images. A vessel detection filter, based on a multi-scale vesselness function, is then applied to enhance vascular structures.

  14. The meningeal sign: a new appraisal

    International Nuclear Information System (INIS)

    Hutzelmann, A.; Palmie, S.; Zimmer, C.; Benz, T.; Leweke, F.; Freund, M.

    1996-01-01

    To evaluate the occurrence of the meningeal sign in meningiomas and metastases. We studied 20 patients with meningiomas and 17 patients with cerebral metastases adjacent to the dura. MRI studies (Siemens, Magnetom 1,5) included axial T 1 -weighted and T 2 -weighted unenhanced as well as gadolinium-DTPA enhanced T 1 -weighted (axial, coronal, sagittal) SE imaging. In all patients the tumours were resected with the attached dura mater. Histopathological examinations were done, which corresponded to the area of marked enhancement by gadolinium-DTPA. There was no correlation between the occurrence of the meningeal sign and the histopathological examinations. In 20 patients with meningiomas adjacent to the dura we found the meningeal sign in 11 cases. Histologically we observed an increase of collagen fibres and fibrocytes. In 5 to 17 cases with superficial cerebral as dura infiltrations and microbleedings. The meningeal sign is not specific for meningiomas and can be observed in a wide variety of pathological entities. (orig.) [de

  15. The CT signs of intestinal volvulus

    International Nuclear Information System (INIS)

    Ji Jiansong; Wang Zufei; Xu Zhaolong; Lv Guijian; Xu Min; Zhao Zhongwei; Su Jinliang; Zhou Limin

    2005-01-01

    Objective: To improve the accuracy rate of spiral CT diagnosing intestinal volvulus. Methods: To analysis the CT findings of 9 cases of intestinal volvulus proved by operation, the main reconstruction techniques were multiplanar reformation (MPR) and sliding thin-slab maximum intensity projection (STS-MIP). Results: All the 9 cases were diagnosed accurately, the main signs were 'whirlpool' of intestine (6 cases) and vessels (9 cases),'target loop' (2 cases),'beak'(6 cases). Conclusion: 'Whirlpool' of vessels is a specific sign to diagnose intestinal volvulus, 'target loop', reduced enhancement of intestinal wall and ascites are the reliable signs to strangulated intestinal obstruction. Spiral CT and reconstructions have important value to diagnose the intestinal volvulus. (authors)

  16. ''Dural tail'' adjacent to acoustic neuroma on MRI: a case report

    International Nuclear Information System (INIS)

    Lunardi, P.; Mastronardi, L.; Nardacci, B.; Acqui, M.; Fortuna, A.

    1993-01-01

    A 'dural tail' on Gd-DTPA-enhanced MRI has been often observed adjacent to meningiomas and considered to be useful in distinguishing meningioma of the cerebellopontine angle from acoustic neuroma. However, demonstration of a dural tail adjacent to an acoustic neuroma indicates that this sign is not specific. (orig.)

  17. Hepatic angiographic findings of ruptured hepatocellular carcinoma: 'Sentinel signs' versus extravasation

    International Nuclear Information System (INIS)

    Yun, Seong Jong; Nam, Deok Ho

    2014-01-01

    This study retrospectively compared the accuracy of angiographic sentinel signs (sentinel vessels, hypovascular areas, and delayed dots) with extravasation in the diagnosis of ruptured hepatocellular carcinoma (HCC). Sixteen patients diagnosed with HCC between March 2007 and November 2011 were evaluated. Among the patients, we identified 32 HCCs (19 ruptured, 13 unruptured), and assessed all HCCs by hepatic angiography with regard to extravasation, sentinel vessels, hypovascular areas, and delayed dots. We compared the sensitivity and specificity of the sentinel signs with those of the extravasation for the diagnosis of a ruptured HCC. For the angiographic diagnosis of a ruptured HCC, the sensitivity of the sentinel signs (sentinel vessel, 63.2%; hypovascular area, 89.5%; delayed dot, 72.7%) was higher than the sensitivity of extravasation (15.8%). The difference in sensitivity between each sentinel sign and extravasation was statistically significant (sentinel vessel, p = 0.012; hypovascular area, p < 0.001; delayed dot, p 0.039). The specificity of sentinel signs for the diagnosis of ruptured HCC was not statistically different from the specificity of extravasation. Sentinel signs are more accurate than extravasation for the angiographic diagnosis of a ruptured HCC.

  18. Study of impact of the AP1000{sup Registered-Sign} reactor vessel upper internals design on fuel performance

    Energy Technology Data Exchange (ETDEWEB)

    Xu Yiban; Conner, Michael; Yuan Kun; Dzodzo, Milorad B.; Karoutas, Zeses; Beltz, Steven A.; Ray, Sumit; Bissett, Teresa A. [Westinghouse Electric Company, Cranberry Township, PA 16066 (United States); Chieng, Ching-Chang, E-mail: cchieng@ess.nthu.edu.tw [National Tsing Hua University, Hsinchu 30043, Taiwan (China); Kao, Min-Tsung; Wu, Chung-Yun [National Tsing Hua University, Hsinchu 30043, Taiwan (China)

    2012-11-15

    One aspect of the AP1000{sup Registered-Sign} reactor design is the reduction in the number of major components and simplification in manufacturing. One design change relative to current Westinghouse reactors of similar size is the reduction in the number of reactor vessel outlet nozzles/hot legs leaving the upper plenum from three to two. With regard to fuel performance, this design difference creates a different flow field in the AP1000 reactor vessel upper plenum (the region above the core). The flow exiting core and entering the upper plenum must turn 90 Degree-Sign , flow laterally through the upper plenum around support structures, and exit through one of the two outlet nozzles. While the flow in the top of the core is mostly axial, there is some lateral flow component as the core flow reacts to the flow field and pressure distribution in the upper plenum. The pressure distribution in the upper plenum varies laterally depending upon various factors including the proximity to the outlet nozzles. To determine how the lateral flow in the top of the AP1000 core compares to current Westinghouse reactors, a computational fluid dynamics (CFD) model of the flow in the upper portion of the AP1000 reactor vessel including the top region of the core, the upper plenum, the reactor vessel outlet nozzles, and a portion of the hot legs was created. Due to geometric symmetry, the computational domain was reduced to a quarter (from the top view) that includes Vulgar-Fraction-One-Quarter of the top of the core, Vulgar-Fraction-One-Quarter of the upper plenum, and Vulgar-Fraction-One-Half of an outlet nozzle. Results from this model include predicted velocity fields and pressure distributions throughout the model domain. The flow patterns inside and around guide tubes clearly demonstrate the influence of lateral flow due to the presence of the outlet nozzles. From these results, comparisons of AP1000 flow versus current Westinghouse plants were performed. Field performance

  19. Skew-signings of positive weighted digraphs

    Directory of Open Access Journals (Sweden)

    Kawtar Attas

    2018-07-01

    Full Text Available An arc-weighted digraph is a pair (D , ω where D is a digraph and ω is an arc-weight function that assigns to each arc u v of D a nonzero real number ω (u v . Given an arc-weighted digraph (D , ω with vertices v 1 , … , v n , the weighted adjacency matrix of (D , ω is defined as the n × n matrix A (D , ω = [ a i j ] where a i j = ω ( v i v j if v i v j is an arc of D , and 0 otherwise. Let (D , ω be a positive arc-weighted digraph and assume that D is loopless and symmetric. A skew-signing of (D , ω is an arc-weight function ω ′ such that ω ′ (u v = ± ω (u v and ω ′ (u v ω ′ (v u < 0 for every arc u v of D . In this paper, we give necessary and sufficient conditions under which the characteristic polynomial of A (D , ω ′ is the same for all skew-signings ω ′ of (D , ω . Our main theorem generalizes a result of Cavers et al. (2012 about skew-adjacency matrices of graphs. Keywords: Arc-weighted digraphs, Skew-signing of a digraph, Weighted adjacency matrix, Mathematics Subject Classification: 05C22, 05C31, 05C50

  20. Pressure vessels and methods of sealing leaky tubes disposed in pressure vessels

    International Nuclear Information System (INIS)

    Larson, G.C.

    1980-01-01

    This invention relates to pressure vessels and to methods of sealing leaky tubes in them and is especially applicable to pressure vessels in the form of sheet-and-tube type heat exchangers constructed with a large number of relatively small diameter tubes grouped in a bundle. To seal off a leaky tube in such a heat exchanger an explosive activated plug in the form of a hollow metal body is used, inserted at each end of the tube to be sealed. Using the arrangement of pressure vessel and associated tube sheets and the explosive activated plug method of sealing a leaky tube as described in this invention it is claimed that distortion of the adjacent tubes and the tube sheets is reduced when the explosive activated plugs are detonated. (U.K.)

  1. The sandwich sign | Mahomed | SA Journal of Radiology

    African Journals Online (AJOL)

    The sandwich sign refers to the sandwiching of mesenteric vessels and fat by enlarged mesenteric nodes on cross-sectional imaging, commonly occurring in lymphoma, but not specific to lymphoma. The sign is radiologically indistinguishable from post-transplant lymphoproliferative disorders. The radiological significance ...

  2. Seals for sealing a pressure vessel such as a nuclear reactor vessel or the like

    International Nuclear Information System (INIS)

    Bruns, H.J.; Huelsermann, K.H.

    1975-01-01

    A description is given of seals for sealing a pressure vessel such as a nuclear reactor vessel, steam boiler vessel, or any other vessel which is desirably sealed against pressure of the type including a housing and a housing closure that present opposed vertical sealing surfaces which define the sides of a channel. The seals of the present invention comprise at least one sealing member disposed in the channel, having at least one stop face, a base portion and two shank portions extending from the base portion to form a groove-like recess. The shank portions are provided with sealing surfaces arranged to mate with the opposed vertical pressure vessel sealing surfaces. A shank-spreading wedge element also disposed in the channel has at least one stop face and is engaged in the groove-like recess with the sealing member and wedge element stop face adjacent to each other

  3. 23 CFR 750.104 - Signs that may not be permitted in protected areas.

    Science.gov (United States)

    2010-04-01

    ... Advertising Adjacent to the Interstate System Under the 1958 Bonus Program § 750.104 Signs that may not be... protected areas: (a) Signs advertising activities that are illegal under State or Federal laws or regulations in effect at the location of such signs or at the location of such activities. (b) Obsolete signs...

  4. JT-60SA vacuum vessel manufacturing and assembly

    Energy Technology Data Exchange (ETDEWEB)

    Masaki, Kei, E-mail: masaki.kei@jaea.go.jp [Japan Atomic Energy Agency, Naka, Ibaraki-ken 311-0193 (Japan); Shibama, Yusuke K.; Sakurai, Shinji; Shibanuma, Kiyoshi; Sakasai, Akira [Japan Atomic Energy Agency, Naka, Ibaraki-ken 311-0193 (Japan)

    2012-08-15

    Highlights: Black-Right-Pointing-Pointer The design of the JT-60SA vacuum vessel body was completed with the demonstration of manufacturing procedure by the mock-up fabrication of the 20 Degree-Sign upper half of VV. Black-Right-Pointing-Pointer The actual VV manufacturing has started since November 2009. Black-Right-Pointing-Pointer The first product of the VV 40 Degree-Sign sector was completed in May 2011. Black-Right-Pointing-Pointer A basic VV assembly scenario and procedure were studied to complete the 360 Degree-Sign VV including positioning method and joint welding. - Abstract: The JT-60SA vacuum vessel (VV) has a D-shaped poloidal cross section and a toroidal configuration with 10 Degree-Sign segmented facets. A double wall structure is adopted to ensure high rigidity at operational load and high toroidal one-turn resistance. The material is 316L stainless steel with low cobalt content (<0.05%). The design temperatures of the VV at plasma operation and baking are 50 Degree-Sign C and 200 Degree-Sign C, respectively. In the double wall, boric-acid water is circulated at plasma operation to reduce the nuclear heating of the superconducting magnets. For baking, nitrogen gas is circulated in the double wall after draining of the boric-acid water. The manufacturing of the VV started in November 2009 after a fundamental welding R and D and a trial manufacturing of 20 Degree-Sign upper half mock-up. The manufacturing of the first VV 40 Degree-Sign sector was completed in May 2011. A basic concept and required jigs of the VV assembly were studied. This paper describes the design and manufacturing of the vacuum vessel. A plan of VV assembly in torus hall is also presented.

  5. An additional ultrasonographic sign of Hashimoto’s lymphocytic thyroiditis in children

    Directory of Open Access Journals (Sweden)

    Wojciech Kosiak

    2015-12-01

    Full Text Available We present an additional sonographic sign of Hashimoto’s thyroiditis (HLT, increasing the specifi city of this method in pediatric populations. Methods: A total of 98 children (mean age 12.7 years, range 7–17 years were selected from the registry of the endocrinology outpatient department. All subjects met the diagnostic criteria for HLT. All children underwent a prospective thyroid ultrasound examination with special attention paid to the presence of lymph nodes adjacent to the thyroid gland. In order to form a control group, we analyzed 102 healthy volunteers and 94 children with cervical lymphadenopathy, age- and sex-matched with the main study group. Results: The ultrasound of the thyroid revealed typical sonographic signs of autoimmune thyroid disease in all children with HLT and in none of the individuals in the control groups. In 96 children (98% from the HLT group, at least 2 lymph nodes adjacent to the lower part of the thyroid gland lobes localized on one or both sides of the thyroid were detected. No lymph nodes adjacent to the lower part of the thyroid lobes were found in healthy children or children with cervical lymphadenopathy. Conclusions: Lymph nodes adjacent to the lower part of the thyroid lobes are an additional ultrasound sign of pediatric Hashimoto’s lymphocytic thyroiditis, with 98% sensitivity and 100% specifi city.

  6. Dural invasion of meningiomas adjacent to the tumor margin on Gd-DTPA-enhanced MR images: histopathologic correlation

    International Nuclear Information System (INIS)

    Hutzelmann, A.; Palmie, S.; Freund, M.; Heller, M.; Buhl, R.

    1998-01-01

    In intracranial meningiomas a flat, contrast-enhancing, dural structure adjacent to the tumor can occasionally be observed on gadolinium-DTPA-enhanced MR images. We wished to evaluate whether there is a correlation between MR images and meningeal invasion of intracranial meningiomas. The study included 54 patients with intracranial meningioma and the meningeal sign. MR studies included T2-weighted and gadolinium-DTPA-enhanced T1-weighted images in axial, coronal, and sagittal planes. Histopathologic examinations were done on the meningiomas adjacent to the dura mater. The meningeal sign on MRI was observed from 2 up to 35 mm from the main tumor mass in 31 (57 %) of the 54 patients. In 20 of these 31 the histopathologic examination showed tumor invasion, while 11 patients had no tumor invasion but tissue proliferation, hypervascularity, and vascular dilatation. Seven of the 23 meningiomas without the meningeal sign had histologically proven infiltration of the adjacent dura. MR imaging is not able to determine definitive whether or not there is dural infiltration of the meningiomas. In conclusion, resection of the tumor with a wide margin is necessary to achieve complete excision of meningioma and to avoid recurrence. (orig.)

  7. Minimization of stress concentration factor in cylindrical pressure vessels with ellipsoidal heads

    International Nuclear Information System (INIS)

    Magnucki, K.; Szyc, W.; Lewinski, J.

    2002-01-01

    The paper presents the problem of stress concentration in a cylindrical pressure vessel with ellipsoidal heads subject to internal pressure. At the line, where the ellipsoidal head is adjacent to the circular cylindrical shell, a shear force and bending moment occur, disturbing the membrane stress state in the vessel. The degree of stress concentration depends on the ratio of thicknesses of both the adjacent parts of the shells and on the relative convexity of the ellipsoidal head, with the range for radius-to-thickness ratio between 75 and 125. The stress concentration was analytically described and, afterwards, the effect of these values on the stress concentration ratio was numerically examined. Results of the analysis are shown on charts

  8. CDC Vital Signs-Heart Age

    Centers for Disease Control (CDC) Podcasts

    This podcast is based on the September 2015 CDC Vital Signs report. Your heart age is the age of your heart and blood vessels as a result of your risk factors for heart attack and stroke. If you smoke or have high blood pressure, your heart age will be much higher than your actual age. Learn what you can do to lower your heart age and keep it low.

  9. Reverse-namaskar: A new sign in Ehlers-Danlos syndrome: A family pedigree study of four generations

    Directory of Open Access Journals (Sweden)

    Premalatha S

    2010-01-01

    Full Text Available Ehlers-Danlos Syndrome (EDS is a rare group of inheritable connective tissue disorder of defective collagen. Skin, joints and blood vessels are most commonly affected. Clinical signs such as Gorlin sign and Metenier sign have been described in this syndrome. We report another new clinical sign called ′Reverse-Namaskar′ sign as an important clinical finding in EDS, based on the family pedigree study of the proband.

  10. Radiological signs of transient tachypnoea and its differential diagnosis

    International Nuclear Information System (INIS)

    Ponhold, W.

    1981-01-01

    The radiological signs of transient tachypnoea are analysed via a study conducted with 9 children suffering from this disturbance of respiratory adaptation. The main signs are reticulonodular structural increases on both sides and extended vessels with unsharp outlines; to a lesser extent, marked small interlobar fissure, signs of an expiratory disturbance of ventilation, and cardiomegaly are seen also. Differentiation against hyaline membranes is easy and delineation against pneumonic and haemorrhagic infiltrations is usually not at all difficult. However, it may be less easy to differentiate between a relatively severe transient tachypnoea and cardiac left decompensation, since the radiological signs resemble each other. Assessment of a chest X-ray film of the newborn should be evaluated in such cases only if the clinical pattern of signs is known, since this is the only way to obtain adequate radiological clarification. (orig.) [de

  11. The reverse boomerang sign: a marker for first-trimester transposition of great arteries.

    Science.gov (United States)

    Bravo-Valenzuela, Nathalie Jeanne; Peixoto, Alberto Borges; Araujo Júnior, Edward; Da Silva Costa, Fabricio; Meagher, Simon

    2017-10-12

    To describe a new sonographic marker of transposition of great arteries (TGA) during the first-trimester screening. We reviewed six cases of TGA from 2013 to 2016 in which an antenatal diagnosis of TGA at first-trimester screening (11-13 + 6 weeks of gestation) was confirmed postnatally. We specifically assessed images obtained by scanning the fetal heart in three vessels (3V) and three-vessel with trachea (3VT) views using color Doppler. The "reverse boomerang" sign was defined as a reverse curvature of right ventricle outflow tract (RVOT) at level of the 3VT view. We described six cases of confirmed TGA, five singletons and one twin pregnancy, among which only two vessels and the reverse curvature of RVOT (reverse boomerang sign) was demonstrated in the first-trimester screening at level of 3VT view. Ventricular septal defects were observed in three cases, and double outlet right ventricle in one case. No other cardiac or extracardiac anomalies were identified. Termination of pregnancy was not performed in any case. Our series case suggests that the reverse boomerang sign may improve the early prenatal screening for TGA.

  12. An analysis of lymphographic signs for differentiating cancerous, lymphomatous, and normal lymph nodes

    International Nuclear Information System (INIS)

    Tatsuzaki, Hideo; Nakajima, Teiichi; Okumura, Toshiyuki; Akisada, Masayoshi

    1987-01-01

    Twenty-four lymphographic signs, obtained from a total of 204 cancerous (C), lymphomatous (L), and normal (N) lymph nodes, were analyzed based on the final diagnosis. Univariate analyses with correlation coefficient and multivariate regression analyses were employed to differentiate C, L, or N lymph nodes. Based on univariate analyses, lymphographic sings for C nodes were - enlarged node, irregular or deficient capsules or marginal sinuses, block of lymph vessels, extravasation, and defect in lymph-vascular and nodal phase (combination defect). The signs for L node were - enlarged node, elliptic shape from 2 projections, irregular or deficient capsules or marginal sinuses, and extravasation. Using multivariate analyses, the following signs were necessary for differentiating individual lymph nodes: (a) combination defect, specific pattern, granularity, nodal shape and stasis or preservation of lymph vessels for differentiating C from N nodes; (b) deficiencies of capsules, nodal shape, specific pattern, dislocation of lymph vessels, and nodal contrast for differentiating L from N nodes; and (c) character of defect, specific pattern, deformity, soft tissue shadow and nodal shape for differentiating C from L nodes. Should lymphography be used in the visualization of inside structure and lymphatic canal, it would even more increase the ability to diagnose cancer and malignant lymphomas. (Namekawa, K.)

  13. Atherosclerotic vessel damage in systemic lupus erythematosus and antiphospholipid syndrome in men

    Directory of Open Access Journals (Sweden)

    A. I. Iljina

    2005-01-01

    Full Text Available Objective. To study prevalence of clinical and subclinical atherosclerosis signs in men with systemic lupus erythematosus (SLE and antiphospholipid syndrome, to assess relationship between atherosclerotic vessel damage, risk factors, CRP and anti-cardiolipin antibodies (АСА Material and methods. 62 pts were included. Mean age was 35,7+11,6 years, mean disease duration - 129,3± 102 months. Traditional and related to the disease risk factors were analyzed. To reveal atherosclerotic vessel damage carotid sonographic examination was performed. Serum CRP concentration was evaluated by high sensitivity nephelometric immunoassay. IgG and IgM АСА were assessed by solid-phase immuno-enzyme assay. Results. Sonographic signs of carotid damage was revealed in 58% of pts, clinical signs of atherosclerosis - in 42%. Pts were divided into two groups according to intima-media complex thickness (IMCT. Group I included 36 pts with atherosclerotic vessel damage signs (IMCT?0,9 mm. Group 2-26 pts with IMCT<0,9 mm. Mean age at the examination, age of disease onset, disease duration, smoking frequency damage index in group I pts were higher than in group 2 pts. Mean CRP concentration in atherosclerosis group was significantly higher than in group 2 (p=0,007. 19 pts had APS signs. 43 pts did not. CRP level significantly correlated with IMCT in SLE pts with and without APS (p<0,05. Pts with atherosclerosis had higher IgG АСА level though the differences were not statistically significant. Conclusion. Men with SLE with or without APS have high risk of atherosclerosis development. CRP elevation is associated with IMCT increase.

  14. Utility of Vascular Enhancement Technique (ClarifyTM) in Ultrasonographic Evaluation of Abdominal Vessels

    International Nuclear Information System (INIS)

    Oh, Jong Young; Cho, Jin Han; Choi, Jong Cheol; Shin, Tae Beom; Lee, Jin Hwa; Yoon, Seong Kuk; Nam, Kyung Jin

    2006-01-01

    Vascular enhancement (VE) technology(ClarifyTM) is a new technique in vascular, B-mode imaging. The purpose of this study was to evaluate the value of VE technology in ultrasonographic diagnosis of abdominal vasculature. Seventy-one adult patients (39 men and 32 women: age range, 25-89 years: mean age, 56 years) who had undergone abdominal ultrasonography were included in this study. The imaging was performed with a 1.8-4.0 MHz convex array transducer (SONOLINE, Antares, Siemens Medical Solutions, WA) by an abdominal radiologist. The radiologist obtained images of the same vascular area with each of conventional ultrasonography imaging (CUS), tissue harmonic imaging (THI), CUS plus VE technique and THI plus VE technique. Images were divided into normal (56) and abnormal (15) groups. The vessel visibility, conspicuity of the vascular wall and contrast resolution with adjacent structures were evaluated in the normal group, and the lesion conspicuity and border sharpness were evaluated in the abnormal group. On the PACS monitor, the images were graded into four grades by two radiologists in consensus. Statistical analysis was performed using Wilcoxon signed rank test. In the normal group, all parameters of the ultrasonographic imaging which applied the VE technique were superior to those of the imaging without VE technique (p < 0.05). In the abnormal group, combined use of VE technique with CUS or THI provided better results than CUS or THI alone in terms of lesion conspicuity and border sharpness (p < 0.05). THI combined with VE technique provided the best image quality among the 4 ultrasonographic methods examined in this study for the evaluation of both normal and abnormal abdominal vessels (p < 0.05). VE technology was a helpful technique to evaluate the abdominal vasculature. Furthermore, VE technique combined with THI provided better image quality than other ultrasonographic methods in the evaluation of abdominal vessels

  15. Sign rank versus Vapnik-Chervonenkis dimension

    Science.gov (United States)

    Alon, N.; Moran, Sh; Yehudayoff, A.

    2017-12-01

    This work studies the maximum possible sign rank of sign (N × N)-matrices with a given Vapnik-Chervonenkis dimension d. For d=1, this maximum is three. For d=2, this maximum is \\widetilde{\\Theta}(N1/2). For d >2, similar but slightly less accurate statements hold. The lower bounds improve on previous ones by Ben-David et al., and the upper bounds are novel. The lower bounds are obtained by probabilistic constructions, using a theorem of Warren in real algebraic topology. The upper bounds are obtained using a result of Welzl about spanning trees with low stabbing number, and using the moment curve. The upper bound technique is also used to: (i) provide estimates on the number of classes of a given Vapnik-Chervonenkis dimension, and the number of maximum classes of a given Vapnik-Chervonenkis dimension--answering a question of Frankl from 1989, and (ii) design an efficient algorithm that provides an O(N/log(N)) multiplicative approximation for the sign rank. We also observe a general connection between sign rank and spectral gaps which is based on Forster's argument. Consider the adjacency (N × N)-matrix of a Δ-regular graph with a second eigenvalue of absolute value λ and Δ ≤ N/2. We show that the sign rank of the signed version of this matrix is at least Δ/λ. We use this connection to prove the existence of a maximum class C\\subseteq\\{+/- 1\\}^N with Vapnik-Chervonenkis dimension 2 and sign rank \\widetilde{\\Theta}(N1/2). This answers a question of Ben-David et al. regarding the sign rank of large Vapnik-Chervonenkis classes. We also describe limitations of this approach, in the spirit of the Alon-Boppana theorem. We further describe connections to communication complexity, geometry, learning theory, and combinatorics. Bibliography: 69 titles.

  16. EVALUATION OF THE COMPUTED TOMOGRAPHIC "SENTINEL CLOT SIGN" TO IDENTIFY BLEEDING ABDOMINAL ORGANS IN DOGS WITH HEMOABDOMEN.

    Science.gov (United States)

    Specchi, Swan; Auriemma, Edoardo; Morabito, Simona; Ferri, Filippo; Zini, Eric; Piola, Valentina; Pey, Pascaline; Rossi, Federica

    2017-01-01

    The CT "sentinel clot sign" has been defined as the highest attenuation hematoma adjacent to a bleeding organ in humans with hemoabdomen. The aims of this retrospective descriptive multicenter study were to describe CT findings in a sample of dogs with surgically or necropsy confirmed intra-abdominal bleeding and determine prevalence of the "sentinel clot sign" adjacent to the location of bleeding. Medical records between 2012 and 2014 were searched for dogs with hemoabdomen and in which the origin of the bleeding was confirmed either with surgery or necropsy. Retrieved CT images were reviewed for the presence and localization of the "sentinel clot sign," HU measurements of the "sentinel clot sign" and hemoabdomen, and presence of extravasation of contrast media within the abdominal cavity. Nineteen dogs were included. Three dogs were excluded due to the low amount of blood that did not allow the identification of a "sentinel clot sign." A "sentinel clot sign" was detected in the proximity of the confirmed bleeding organ in 14/16 (88%) of the patients. The mean HU of the "sentinel clot sign" was 56 (range: 43-70) while that of the hemoabdomen was 34 (range: 20-45). Active hemorrhage was identified as extravasation of contrast medium within the peritoneal cavity from the bleeding organ in three dogs. In conclusion, the CT "sentinel clot sign" may be helpful for identifying the source of bleeding in dogs with hemoabdomen. © 2016 American College of Veterinary Radiology.

  17. Apparatus for carrying out ultrasonic inspection of pressure vessels

    International Nuclear Information System (INIS)

    Dent, K.H.; Challender, R.S.

    1975-01-01

    Apparatus is described for use in carrying out ultrasonic inspection of coolant nozzles of nuclear reactor pressure vessels. It comprises a manipulator for supporting an ultrasonic scanning transducer within the coolant nozzle. The manipulator is carried by a support located within the pressure vessel and comprises a pair of legs pivotable in caliper manner to span the base of the nozzle. Means are provided for pivoting the legs together to enable free entry of the manipulator and scanning transducer into the nozzle, and for pivoting the legs apart to bring the transducer into an operating position adjacent to the wall of the nozzle. The manipulator is rotatable within the nozzle to enable scanning of its interior surface. (U.K.)

  18. CDC Vital Signs-Heart Age

    Centers for Disease Control (CDC) Podcasts

    2015-09-01

    This podcast is based on the September 2015 CDC Vital Signs report. Your heart age is the age of your heart and blood vessels as a result of your risk factors for heart attack and stroke. If you smoke or have high blood pressure, your heart age will be much higher than your actual age. Learn what you can do to lower your heart age and keep it low.  Created: 9/1/2015 by National Center for Chronic Disease Prevention and Health Promotion (NCCDPHP).   Date Released: 9/1/2015.

  19. Mechanism of endothelial progenitor cell recruitment into neo-vessels in adjacent non-tumor tissues in hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Yu, De-cai; Chen, Jun; Sun, Xi-tai; Zhuang, Lin-yuan; Jiang, Chun-ping; Ding, Yi-tao

    2010-01-01

    We investigated the distribution and clinical significance of mobilized endothelial progenitor cells (EPCs) in hepatocellular carcinoma (HCC). We found that many more EPCs were recruited to nonmalignant liver tissue (especially into adjacent non-tumor tissues (AT)) than to tumor vessels. These results suggest that the mechanism underlying the recruitment of EPCs into microvessels in AT merits further investigation Angiogenic factors were detected in three tissue microarrays comprising normal liver, paired tumor tissue (TT) and AT from 105 patients (who had undergone hepatectomy for HCC) using immunohistochemistry. Also, the number of EPCs (positive for Sca-1, Flk-1 and c-Kit) in the blood and liver of cirrhotic mice were determined by flow cytometry and immunohistochemistry. The distribution of these labeled EPCs in tumor and non-tumor tissues was then studied. The results from the tissue microarrays showed that the expression levels of VEGF-A, bFGF, TGF-β, MCP-1, TSP-1, MMP-9, TIMP-2, and endostatin were significantly higher in AT than in either normal liver or TT (p < 0.05), but no significant difference was found in the expression levels of COX-2 and NOS-2 between AT and TT. The expression of VEGF-A, bFGF, TGF-β, MCP-1, TSP-1, MMP-9, TIMP-2, endostatin, COX-2, and NOS-2 in normal liver tissue was weaker than that in AT or TT. In cirrhotic mice, the number of circulating endothelial progenitor cells gradually increased, before decreasing again. In this mouse model, increased numbers of EPCs were recruited and homed specifically to the cirrhotic liver. Both liver cirrhosis and HCC led to increased expression of pro-angiogenic factors, which resulted in the recruitment of EPCs into AT. Also, EPCs were mobilized, recruited and homed to cirrhotic liver. The unique pathology of HCC coupled with liver cirrhosis may, therefore, be associated with the distribution and function of EPCs

  20. TMI-2 Vessel Investigation Project Metallurgical Program

    International Nuclear Information System (INIS)

    Diercks, D.R.; Neimark, L.A.

    1990-01-01

    The TMI-2 [Three Mile Island unit 2] Vessel Investigation Project Metallurgical Program at Argonne National Laboratory is a part of the international TMI-2 Vessel Investigation Project being conducted jointly by the U.S. Nuclear Regulatory Commission and the Organization for Economic Co-operation and Development (OECD). The overall project consists of three phases, namely (1) recovery of material samples from the lower head of the TMI-2 reactor, (2) examination and analysis of the lower head samples and the preparation and testing of archive material subjected to a similar thermal history, and (3) procurement, examination, and analysis of companion core material located adjacent to or near the lower head material. The specific objectives of the ANL Metallurgical Program, which accounts for a major portion of Phase 2, are to prepare metallographic and mechanical test specimen blanks from the TMI-2 lower head material, prepare similar test specimen blanks from suitable archive material subjected to the appropriate thermal processing, determine the mechanical properties of the lower vessel head and archive materials under the conditions of the core-melt accident, and assess the lower head integrity and margin-to-failure during the accident. The ANL work consists of three tasks: (1) archive materials program, (2) fabrication of metallurgical and mechanical test specimens from the TMI-2 pressure vessel samples, and (3) mechanical property characterization of TMI-2 lower pressure vessel head and archive material

  1. Diaphragmatic lymphatic vessel behavior during local skeletal muscle contraction.

    Science.gov (United States)

    Moriondo, Andrea; Solari, Eleonora; Marcozzi, Cristiana; Negrini, Daniela

    2015-02-01

    The mechanism through which the stresses developed in the diaphragmatic tissue during skeletal muscle contraction sustain local lymphatic function was studied in 10 deeply anesthetized, tracheotomized adult Wistar rats whose diaphragm was exposed after thoracotomy. To evaluate the direct effect of skeletal muscle contraction on the hydraulic intraluminal lymphatic pressures (Plymph) and lymphatic vessel geometry, the maximal contraction of diaphragmatic fibers adjacent to a lymphatic vessel was elicited by injection of 9.2 nl of 1 M KCl solution among diaphragmatic fibers while Plymph was recorded through micropuncture and vessel geometry via stereomicroscopy video recording. In lymphatics oriented perpendicularly to the longitudinal axis of muscle fibers and located at skeletal muscle contraction (Dmc) decreased to 61.3 ± 1.4% of the precontraction value [resting diameter (Drest)]; however, if injection was at >900 μm from the vessel, Dmc enlarged to 131.1 ± 2.3% of Drest. In vessels parallel to muscle fibers, Dmc increased to 122.8 ± 2.9% of Drest. During contraction, Plymph decreased as much as 22.5 ± 2.6 cmH2O in all submesothelial superficial vessels, whereas it increased by 10.7 ± 5.1 cmH2O in deeper vessels running perpendicular to contracting muscle fibers. Hence, the three-dimensional arrangement of the diaphragmatic lymphatic network seems to be finalized to efficiently exploit the stresses exerted by muscle fibers during the contracting inspiratory phase to promote lymph formation in superficial submesothelial lymphatics and its further propulsion in deeper intramuscular vessels. Copyright © 2015 the American Physiological Society.

  2. 23 CFR 750.107 - Class 3 and 4 signs outside informational sites.

    Science.gov (United States)

    2010-04-01

    ... areas. (6) Not more than one such sign advertising activities being conducted as a single enterprise or... ENVIRONMENT HIGHWAY BEAUTIFICATION National Standards for Regulation by States of Outdoor Advertising Adjacent... traffic not served by an informational site within 12 air miles of the advertised activity; (2) Class 4...

  3. TMI-2 Vessel Investigation Project (VIP) Metallurgical Program

    International Nuclear Information System (INIS)

    Diercks, D.R.; Neimark, L.A.

    1990-06-01

    The TMI-2 Vessel Investigation Project (VIP) Metallurgical Program is a part of the international TMI-2 Vessel Investigation Project being conducting jointly by the US Nuclear Regulatory Commission and the Organization for Economic Co-operation and Development (OECD). The overall project consists of three phases, namely (1) recovery of material samples from the lower head of the TMI-2 reactor, (2) examination and analysis of the lower head samples and the preparation and testing of archive material subjected to a similar thermal history, and (3) procurement, examination, and analysis of companion core material located adjacent to or near the lower head material. The specific objectives of the ANL Metallurgical Program, which comprises a major portion of Phase 2, are to prepare metallographic and mechanical test specimen blanks from the TMI-2 lower head material, prepare similar test specimen blanks from suitable archive material subjected to the appropriate thermal processing, determine the mechanical properties of the lower vessel head and archive materials under the conditions of the core-melt accident, and assess the lower head integrity and margin-to-failure during the accident. The ANL work consists of three tasks: (1) archive materials program, (2) fabrication of metallurgical and mechanical test specimens from the TMI-2 pressure vessel samples, and (3) mechanical property characterization of TMI-2 lower pressure vessel head and archive material

  4. 50 CFR 660.312 - Vessel Monitoring System (VMS) requirements.

    Science.gov (United States)

    2010-10-01

    .... The communications service provider receives the transmission and relays it to NMFS OLE. (b) Who is... relay transmissions to NMFS OLE prior to fishing: (1) Any vessel registered for use with a limited entry... reports. Signed long-term departure exemption reports must be submitted by fax or by emailing a electronic...

  5. Relevant signs of stable and unstable thoracolumbar vertebral column trauma

    International Nuclear Information System (INIS)

    Gehweiler, J.A.; Daffner, R.H.; Osborne, R.L.

    1981-01-01

    One-hundred and seventeen patients with acute thoracolumbar vertebral column fracture or fracture-dislocations were analyzed and classified into stable (36%) and unstable (64%). Eight helpful roentgen signs were observed that may serve to direct attention to serious underlying, often occult, fractures and dislocations. The changes fall into four principal groups: abnormal soft tissues, abnormal vertebral alignment, abnormal joints, and widened vertebral canal. All stable and unstable lesions showed abnormal soft tissues, while 70% demonstrated kyphosis and/or scoliosis, and an abnormal adjacent intervertebral disk space. All unstable lesions showed one or more of the following signs: displaced vertebra, widened interspinous space, abnormal apophyseal joint(s), and widened vertebral canal. (orig.)

  6. Stress analysis of blanket vessel for JAERI experimental fusion reactor

    International Nuclear Information System (INIS)

    Sako, K.; Minato, A.

    1979-01-01

    A blanket structure of JAERI Experimental Fusion Reactor (JXFR) consists of about 2,300 blanket cells with round cornered rectangular cross sections (twelve slightly different shapes) and is placed in a vacuum vessel. Each blanket vessel is a double-walled thin-shell structure made of Type 316 stainless steel with a spherical domed surface at the plasma side. Ribs for coolant channel are provided between inner and outer walls. The blanket cell contains Li 2 O pebbles and blocks for tritium breeding and stainless steel blocks for neutron reflection. A coolant is helium gas at 10 kgf/cm 2 (0.98 MPa) and its inlet and outlet temperatures are 300 0 C and 500 0 C. The maxima of heat flux and nuclear heating rate at the first wall are 12 W/cm 2 and 2 W/cc. A design philosophy of the blanket structure is based on high tritium breeding ratio and more effective shielding performance. The thin-shell vessel with a rectangular cross section satisfies the design philosophy. We have designed the blanket structure so that the adjacent vessels are mutually supporting in order to decrease the large deformation and stress due to internal pressure in case of the thin-shell vessel. (orig.)

  7. Collateral vessels in moyamoya disease : comparison of MR and MRA with conventional angiography

    International Nuclear Information System (INIS)

    Shim, Joo Eun; Yoon, Dae Young; Yi, Jeong Geun; Kim, Ho Chul; Choi, Chul Sun; Bae, Sang Hoon

    1998-01-01

    To determine the value of magnetic resonance imaging (MR) and magnetic resonance angiography (MRA) in assessing collateral vessels of moyamoya disease. Twenty-four patients with moyamoya disease who underwent MR, 3D TOF MRA, and conventional angiography participated in this study. Two radiologists working independently and with no knowledge of the angiographic findings, interpreted the MR and MRA images. To determine the presence of parenchymal and leptomeningeal collaterals (48 hemispheres) and transdural collaterals (38 hemispheres in 19 patients were depicted by angiography of the external carotid), the findings were compared with those of angiography. Parenchymal, leptomeningeal, and transdural collaterals were depicted by conventional angiography in 34 (71%), 32 (67%), and 11 (29%) hemispheres respectively. The sensitivity and specificity of MR/MRA for collateral vessels were 79.1/88.1 % for parenchymal collaterals, 72.1/88.1 % for leptomeningeal collaterals, and 0.1/18.1 % for transdural collaterals, respectively. Respective sensitivity and specificity of MR/MRA were 88.94/94.1% for leptomeningeal collaterals, and 18.93/55.1 % for transdural collaterals, when the prominent posterior cerebral and external carotid artery were regarded as secondary signs of leptomeningeal and transdural collateral vessels. In moyamoya disease, MR and MRA are useful imaging modalities for the assessment of collateral vessels. The prominent posterior cerebral artery and external carotid artery can be useful secondary signs of leptomeningeal and transdural collateral vessels. (author). 18 refs., 2 figs

  8. Application of morphological bit planes in retinal blood vessel extraction.

    Science.gov (United States)

    Fraz, M M; Basit, A; Barman, S A

    2013-04-01

    The appearance of the retinal blood vessels is an important diagnostic indicator of various clinical disorders of the eye and the body. Retinal blood vessels have been shown to provide evidence in terms of change in diameter, branching angles, or tortuosity, as a result of ophthalmic disease. This paper reports the development for an automated method for segmentation of blood vessels in retinal images. A unique combination of methods for retinal blood vessel skeleton detection and multidirectional morphological bit plane slicing is presented to extract the blood vessels from the color retinal images. The skeleton of main vessels is extracted by the application of directional differential operators and then evaluation of combination of derivative signs and average derivative values. Mathematical morphology has been materialized as a proficient technique for quantifying the retinal vasculature in ocular fundus images. A multidirectional top-hat operator with rotating structuring elements is used to emphasize the vessels in a particular direction, and information is extracted using bit plane slicing. An iterative region growing method is applied to integrate the main skeleton and the images resulting from bit plane slicing of vessel direction-dependent morphological filters. The approach is tested on two publicly available databases DRIVE and STARE. Average accuracy achieved by the proposed method is 0.9423 for both the databases with significant values of sensitivity and specificity also; the algorithm outperforms the second human observer in terms of precision of segmented vessel tree.

  9. ITER vacuum vessel design (D201 subtask 1.3 and subtask 3). Final report

    International Nuclear Information System (INIS)

    1996-01-01

    ITER Task No. D201, Vacuum Vessel Design (Subtask 1.3 and Subtask 3), was initiated to propose and evaluate local vacuum vessel reinforcement alternatives in proximity to the Neutral Beam, Radial Mid-Plane, Top, and Divertor Ports. These areas were reported to be highly stressed regions based on the results of preliminary stress analyses performed by the USHT (US Home Team) and the ITER Joint Central Team (JCT) at the Garching JWS (Joint Work Site). Initial design activities focused on the divertor port region which was reported to experience the highest stress intensities. Existing stress analysis models and results were reviewed with the USHT stress analysts to obtain an overall understanding of the vessel response to the various applied loads. These reviews indicated that the reported stress intensities in the divertor port region were significantly affected by the loads applied to the vessel in adjacent regions

  10. PWR reactor pressure vessel failure probabilities

    International Nuclear Information System (INIS)

    Dufresne, J.; Lanore, J.M.; Lucia, A.C.; Elbaz, J.; Brunnhuber, R.

    1980-05-01

    To evaluate the rupture probability of a LWR vessel a probabilistic method using the fracture mechanics under probabilistic form has been proposed previously, but it appears that more accurate evaluation is possible. In consequence a joint collaboration agreement signed in 1976 between CEA, EURATOM, JRC Ispra and FRAMATOME set up and started a research program covering three parts: a computer code development, data acquisition and processing, and a support experimental program which aims at clarifying the most important parameters used in the COVASTOL computer code

  11. MORPHOMETRIC STUDY OF THE AREOLAR SPACE BETWEEN THE GREAT VESSELS AND THE LUMBAR SPINE

    Directory of Open Access Journals (Sweden)

    Luis Marchi

    2015-12-01

    Full Text Available Objective : This work aims to study the areolar space anterior to the lumbar spine, and also the positioning of the large vessels focusing a lateral approach. Methods :This is a morphometric study of 108 cases based on T2 weighted-MRI images in the supine position. The following measurements were performed: lumbar and segmental lordosis; anteroposterior disc diameter; space between the disc/vertebral body and the vessels; bifurcation between the abdominal aorta and the common iliac veins confluence in relation to the lumbar level. Results :The areolar space with respect to the iliac veins, and with the vena cava increased cranially (p<0.001, starting from average 0.6mm at L4-L5 and reaching 8.4mm at L2, while the abdominal aorta showed no increase or decrease pattern across the different levels (p=0.135 ranging from 1.8 to 4.6mm. The diameter of the discs increased distally (p<0.01 as well as the lordosis (p<0.001. The disc diameter was 11% larger when compared to the adjacent vertebral bodies (p<0.001 and that resulted in a smaller distance of the vessels in the disc level than in the level of the adjacent vertebral bodies (p<0.001. The aortic bifurcation was generally ahead of L4 (52% and less frequently at L3-L4 (28% and L4-L5 (18%. The confluence of the veins was usually at the L4-L5 level (38% and at L5 (37%, and less frequently at L4 (26%. Conclusions : There is an identifiable plane between the great vessels and the lumbar spine which is particularly narrow in its distal portion. It is theoretically feasible to reach this plan, handle the anterior complex disc/ALL and protect the great vessels by lateral approach, however, it is challenging.

  12. Significance of collateral vessels on the prediction of superior vena cava syndrome on CT

    International Nuclear Information System (INIS)

    Kim, Hyun Sook; Kim, Hyung Jin; Lee, Hyeng Gon; Ahn, In Oak; Chung, Sung Hoon

    1993-01-01

    Although visible collateral vessels on computed tomography (CT) has been considered as an important finding in superior vena cava (SVC) syndrome, there is no systematical analysis concerning correlation between the CT evidence of collateral vessels and clinical evidence of SVC syndrome. The purpose of this study is to evaluate how accurately we predict the clinical presence of SVC syndrome by the collateral vessels in patients with apparent SVC obstruction in CT. Forty seven patients having a CT evidence of obstruction or compression of SVC and/or its major tributaries were included in this study. Lung cancer was the most common underlying disease (n=40). The enhanced CT scans were obtained through either arm vein using a combined bolus and drip-infusion technique. Analyzing the CT scans, we particularly paid attention to the site and pattern of venous compromise, presence of collateral vessels, and if present, their location, without knowing whether symptoms and sign were present or nor, and then compared them with clinical data by a thorough review of charts, To verify the frequency of visible collateral vessels in normal subjects, we also evaluated the CT scans of 50 patients without mediastinal disease and clinical SVC syndrome as a control group. On CT, collateral vessels were found in 24 patients, among whom three patient had a single collateral and 21 patients had two or more collateral channels. There were two false positive cases, in which clinically overt SVC syndrome appeared 10 days and three months after CT examination respectively, and one false negative case. The presence of collateral vessels on CT, respectively, and one false negative case. The presence of collateral vessels on CT, regardless of the number and location of collateral vessels and pattern of venous obstruction, was a good clue for predicting the presence of clinical SVC syndrome with the sensitivity and the specificity of 95.7% and 91.7%, respectively. In control group, collateral

  13. Safety effects of traffic signing for left turn flashing yellow arrow signals.

    Science.gov (United States)

    Schattler, Kerrie L; Gulla, Cody J; Wallenfang, Travis J; Burdett, Beau A; Lund, Jessica A

    2015-02-01

    In 2010, the left turn flashing yellow arrow (FYA) signal displays were installed at signalized intersections on state routes in the Peoria, Illinois, area. Supplemental traffic signs with text "Left Turn Yield on Flashing Yellow Arrow" were mounted on the mast arm adjacent to the left turn signal at over half of the FYA installations. The purpose of this paper is to present the results of the effectiveness evaluation of the FYA supplemental sign on safety. Analyses are presented on the effects of the FYA supplemental sign for all drivers and a subset of drivers age 65 and older. A crash-based comparison of 164 FYA approaches including 90 approaches with the sign and 74 approaches without the sign showed greater crash reductions when the supplemental FYA sign was present. The results also showed that crashes involving drivers age 65 and older did not experience the same magnitudes of crash reductions as compared to all drivers. The findings of this research indicate that supplemental FYA signs may help in improving safety for left-turning vehicles during the permissive interval. Thus, it is recommended that supplemental signs be used when initially implementing the FYA, and that effort to educate the driving public on new traffic control be made to further improve safety at signalized intersections. Copyright © 2014. Published by Elsevier Ltd.

  14. CT morphology of splenic vessels in splenoportal fistula

    Energy Technology Data Exchange (ETDEWEB)

    Mansfeld, L; Poehls, C; Boitz, F

    1986-12-01

    CT examination of a 53-year-old patient with endocarditis and clinical signs of hepatosplenomegaly revealed an atypical vascular morphology in the hilum of the spleen, for which no diagnosis could be established. Angiography indicated the presence of a symptom-free splenoportal fistula, the histological study of which suggested its congenital genesis. The paper describes the morphology, as ascertained by CT, of the splenic vessels characterised by changed haemodynamics due to a hilar splenoportal fistula.

  15. Skew-adjacency matrices of graphs

    NARCIS (Netherlands)

    Cavers, M.; Cioaba, S.M.; Fallat, S.; Gregory, D.A.; Haemers, W.H.; Kirkland, S.J.; McDonald, J.J.; Tsatsomeros, M.

    2012-01-01

    The spectra of the skew-adjacency matrices of a graph are considered as a possible way to distinguish adjacency cospectral graphs. This leads to the following topics: graphs whose skew-adjacency matrices are all cospectral; relations between the matchings polynomial of a graph and the characteristic

  16. Breast Cancer Arising Adjacent to an Involuting Fibroadenoma: Serial Changes in Radiologic Features

    Science.gov (United States)

    Park, Chae Jung; Kim, Eun-Kyung; Woo, Ha Young; Moon, Hee Jung; Yoon, Jung Hyun

    2015-01-01

    Fibroadenoma is a common benign breast lesion and its malignant transformation is rare. There have been several case reports and studies that retrospectively reviewed breast cancers that arose within fibroadenomas; however, none of these studies reported serial changes in radiologic features of the cancer, including findings from mammography and ultrasound (US). We report a case of breast cancer arising adjacent to an involuting fibro adenoma in a 39-year-old woman who was undergoing serial follow-up after her fibroadenoma was diagnosed. Seven years after her diagnosis, the lesion showed evidence of coarse calcifications, a typical sign of involution. Four years later, US revealed a newly developed hypoechoic lesion with irregular margins and peripherally located calcifications adjacent to the fibroadenoma. A core biopsy was performed, and histopathological examination resulted in a diagnosis of invasive ductal carcinoma. When new suspicious features are observed in a fibroadenoma, radiologists should raise the concern for breast cancer and proceed with diagnosis and treatment accordingly. PMID:26472981

  17. Name signs in Danish Sign Language

    DEFF Research Database (Denmark)

    Bakken Jepsen, Julie

    2018-01-01

    in spoken languages, where a person working as a blacksmith by his friends might be referred to as ‘The Blacksmith’ (‘Here comes the Blacksmith!’) instead of using the person’s first name. Name signs are found not only in Danish Sign Language (DSL) but in most, if not all, sign languages studied to date....... This article provides examples of the creativity of the users of Danish Sign Language, including some of the processes in the use of metaphors, visual motivation and influence from Danish when name signs are created.......A name sign is a personal sign assigned to deaf, hearing impaired and hearing persons who enter the deaf community. The mouth action accompanying the sign reproduces all or part of the formal first name that the person has received by baptism or naming. Name signs can be compared to nicknames...

  18. Evaluation of structural reliability for vacuum vessel under external pressure and electromagnetic force

    International Nuclear Information System (INIS)

    Minato, Akio

    1983-08-01

    Static and dynamic structural analyses of the vacuum vessel for a Swimming Pool Type Tokamak Reactor (SPTR) have been conducted under the external pressure (hydraulic and atmospheric pressure) during normal operation or the electromagnetic force due to plasma disruption. The reactor structural design is based on the concept that the adjacent modules of the vacuum vessel are not connected mechanically with bolts in the torus inboard region each other, so as to save the required space for inserting the remote handling machine for tightenning and untightenning bolts in the region and to simplify the repair and maintenance of the reactor. The structural analyses of the vacuum vessel have been carried out under the external pressure and the electromagnetic force and the structural reliability against the static and dynamic loads is estimated. The several configurations of the lip seal between the modules, which is required to make a plasma vacuum boundary, have been proposed and the structural strength under the forced displacements due to the deformation of the vacuum vessel is also estimated. (author)

  19. CT morphology of splenic vessels in splenoportal fistula

    International Nuclear Information System (INIS)

    Mansfeld, L.; Poehls, C.; Boitz, F.

    1986-01-01

    CT examination of a 53-year-old patient with endocarditis and clinical signs of hepatosplenomegaly revealed an atypical vascular morphology in the hilum of the spleen, for which no diagnosis could be established. Angiography indicated the presence of a symptom-free splenoportal fistula, the histological study of which suggested its congenital genesis. The paper describes the morphology, as ascertained by CT, of the splenic vessels characterised by changed haemodynamics due to a hilar splenoportal fistula. (orig.) [de

  20. On the System of Person-Denoting Signs in Estonian Sign Language: Estonian Name Signs

    Science.gov (United States)

    Paales, Liina

    2010-01-01

    This article discusses Estonian personal name signs. According to study there are four personal name sign categories in Estonian Sign Language: (1) arbitrary name signs; (2) descriptive name signs; (3) initialized-descriptive name signs; (4) loan/borrowed name signs. Mostly there are represented descriptive and borrowed personal name signs among…

  1. Immediate management of epistaxis: bloody nuisance or ominous sign?

    Science.gov (United States)

    Davidson, T M; Davidson, D

    1996-08-01

    Epistaxis typically originates from the nasal septum when the nasal mucosa overlying a dilated blood vessel is injured. Epistaxis may, however, signal an underlying condition such as a coagulation disorder, so the treating physician must be alert for signs of serious illness. Most nosebleeds stop spontaneously within 5 minutes with or without pressure to the forehead, nose, or upper lip. Some require anterior nasal packing. A few arise from posterior arteries and require anterior-posterior nasal packing and a referral.

  2. TEMP-STRESS analysis of a reinforced concrete vessel under internal pressure

    International Nuclear Information System (INIS)

    Marchertas, A.H.; Kennedy, J.M.; Pfeiffer, P.A.

    1987-01-01

    The TEMP-STRESS FEM represents an axisymmetric simulation of the reinforced concrete vessel to internal pressurization. The information shows the global deformation, the state of strain/stress within the containment vessel with respect to the imposed pressures. Thus, the location and progress of concrete cracking, the stretching of the liner and the reinforcing bars and final failure are indicated through the entire loading range. Equilibrium of the entire system is assured at definite loading increments. With the progress of concrete cracking, the resisting load is continuously transferred to the reinforcing bars and the liner. Thus, after the tensile strength is exceeded and the concrete stress is set to zero, the internal pressures are entirely resisted by the liner and the reserve strength of the reinforcing bars. The reinforcing bars are mechanically connected to each other by splices, the ultimate strength of which is less than that of the rebars themselves. The corresponding strain at this limiting stress is lower than the ultimate strain of the liner. Therefore, the specified ultimate strength of the splices limits the pressurization of the vessel. Furthermore, once any of the splices fail, then load is transferred to the adjacent members, causing their failure and general failure of the vessel. (orig./HP)

  3. Leptomeningeal high signal intensity (ivy sign) on fluid-attenuated inversion-recovery (FLAIR) MR images in moyamoya disease

    Energy Technology Data Exchange (ETDEWEB)

    Fujiwara, Hirokazu [Department of Diagnostic Radiology, School of Medicine, Keio University, Tokyo 1608582 (Japan)]. E-mail: hirokazu_fujiwara@ybb.ne.jp; Momoshima, Suketaka [Department of Diagnostic Radiology, School of Medicine, Keio University, Tokyo 1608582 (Japan); Kuribayashi, Sachio [Department of Diagnostic Radiology, School of Medicine, Keio University, Tokyo 1608582 (Japan)

    2005-08-01

    Purpose: There are a few reports on leptomeningeal high signal intensity (LMHI: ivy sign) on fluid-attenuated inversion-recovery (FLAIR) images in moyamoya disease, but the feature of this finding has not been completely understood. The purpose of this study was to characterize LMHI on FLAIR images in moyamoya disease and to assess usefulness of this finding in the diagnosis of moyamoya disease in conventional MR imaging. Material and methods: MR imaging of 28 patients with moyamoya disease was retrospectively reviewed. The grade of LMHI on FLAIR images was classified as 'absent,' 'minimal,' 'moderate' and 'marked.' Fifty-four hemispheres of 28 patients (2 patients had unilateral disease) were assessed for the frequency of visualization and distribution of LMHI. The correlations between LMHI on FLAIR images, moyamoya vessels on T1- and T2-weighted images and MR angiography findings were also analyzed. Results: Moderate and marked LMHI was seen in 31 out of 54 hemispheres (57%). LMHI was seen more prominently in the frontal and parietal lobes than in the temporal and occipital lobes. Although there was a tendency for LMHI on FLAIR images to be prominent in groups with moderate and marked moyamoya vessels on T1- and T2-weighted images, there was no significant correlation. More prominent LMHI was observed in the hemispheres in which cortical branches of the middle cerebral arteries were poorly visualized on MR angiography. Conclusion: Leptomeningeal high signal intensity (ivy sign) on FLAIR images is predominantly seen in the frontal and parietal lobes. Because this sign can be seen in patients with unremarkable moyamoya vessels, LMHI is a useful sign in conventional MR imaging for the diagnosis of moyamoya disease.

  4. An approach to localize the retinal blood vessels using bit planes and centerline detection.

    Science.gov (United States)

    Fraz, M M; Barman, S A; Remagnino, P; Hoppe, A; Basit, A; Uyyanonvara, B; Rudnicka, A R; Owen, C G

    2012-11-01

    The change in morphology, diameter, branching pattern or tortuosity of retinal blood vessels is an important indicator of various clinical disorders of the eye and the body. This paper reports an automated method for segmentation of blood vessels in retinal images. A unique combination of techniques for vessel centerlines detection and morphological bit plane slicing is presented to extract the blood vessel tree from the retinal images. The centerlines are extracted by using the first order derivative of a Gaussian filter in four orientations and then evaluation of derivative signs and average derivative values is performed. Mathematical morphology has emerged as a proficient technique for quantifying the blood vessels in the retina. The shape and orientation map of blood vessels is obtained by applying a multidirectional morphological top-hat operator with a linear structuring element followed by bit plane slicing of the vessel enhanced grayscale image. The centerlines are combined with these maps to obtain the segmented vessel tree. The methodology is tested on three publicly available databases DRIVE, STARE and MESSIDOR. The results demonstrate that the performance of the proposed algorithm is comparable with state of the art techniques in terms of accuracy, sensitivity and specificity. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  5. Effect of static electronic advertising signs on road safety: an experimental case study.

    Science.gov (United States)

    Izadpanah, Pedram; Omrani, Reza; Koo, Sheldon; Hadayeghi, Ali

    2014-01-01

    As technology continues to advance, the outdoor advertising industry is taking advantage of electronic signs, some of which are static electronic signs (SES), with the ability to automatically change the message shown on the sign at regular intervals. Studies indicate that SES has a negative impact on the drivers' visual attention and on vehicle control. However, the actual effects of the SES on the number of collisions have been difficult to prove conclusively. The objective of this article is to generate a clear understanding of the safety impacts of SES on the number collisions by conducting a before-and-after analysis with comparison groups. The analysis was based on a total of 10 SES along the Highway 27 and the Gardiner Expressway of the city of Toronto. The results of the before-and-after study revealed that there was not enough evidence to suggest that these signs have any impact on road safety along the adjacent roadway sections at a 95% confidence interval. The same results were obtained by comparing collisions that occurred during daylight and artificial light.

  6. Embrittlement of the nuclear icebreaker Lenin reactor pressure vessel materials reconstruction

    International Nuclear Information System (INIS)

    Krasikov, E.A.; Nikolaenko, V.A.

    2008-01-01

    Paper deals with the results of the efforts to examine the radiation damage of the Lenin nuclear-powered ice-breaker decommissioned reactor pressure vessel on the basis of which one has determined the peculiar features of the metal radiation embrittlement. Under 10 10 -10 11 s -1 cm -2 low density neutron flux irradiation one notes the most intensive embrittlement of the metal. Then, as the noxious element content in the metal matrix grows smaller the embrittlement reduces up to the change of sign as to the normal curve plotted at the neutron flux density exceeding 10 13 s -1 cm -2 . One assumes that as a result of the low density neutron flux irradiation the reactor pressure vessel edge spaces at some operation stages may be damaged more severely in contrast to these near the reactor core. The neutron irradiation density is the factor affecting the reactor vessel material embrittlement, that is why, it is important to study the damage mechanism of the materials of the power reactor vessels under design characterized by the low radiation load. The mentioned is important, as well, to evaluate the efficiency of the efforts undertaken to mitigate the effect of the neutron radiation on the reactor vessel [ru

  7. Comparison of fishes taken by a sportfishing party vessel around oil platforms and adjacent natural reefs near Santa Barbara, California

    International Nuclear Information System (INIS)

    Love, M.S.; Westphal, W.

    1990-01-01

    Since 1958, 29 oil platforms have been sited in the southern California Bight of which 28 still remain in place. However, little is known of the fish populations surrounding these structures, particularly those sited in water deeper than 30 m. In the course of research on the Santa Barbara, California, party vessel sport fishery, it was noted that the platforms off Santa Barbara supported considerable sportfishing activity. Those platforms, located to the southeast of Santa Barbara in depths of 48-62 m, were particularly important and were fished intensively for various rockfishes (genus Sebastes). When fishing a platform, the vessel pulled up to within 5-10 m of a platform and drifts along one side, with the vessel operator using intermittent power to keep it near the structure. Most of the desirable species, particularly rockfishes, remained close to the platforms, rarely venturing more than perhaps 20 m from the structure. The party vessels also spent considerable time fishing over nearby natural reefs. In this survey, it was noted that there appeared to be differences in species catch composition and fish size between oil platforms and these natural reefs. Increased offshore oil drilling off California has raised interest in the role platforms play in marine systems. Questions have been raised regarding what fish live around platforms, how these structures influence populations over surrounding reefs, and whether the platforms act as fish enhancers (promoting recruitment) or only as aggregators. These questions are particularly relevant when the platforms are to be decommissioned and the possibility of allowing them to remain as artificial reefs is raised. This paper describes the results of the study on the fish populations around oil platforms and nearby natural reefs off Santa Barbara

  8. Novel method for edge detection of retinal vessels based on the model of the retinal vascular network and mathematical morphology

    Science.gov (United States)

    Xu, Lei; Zheng, Xiaoxiang; Zhang, Hengyi; Yu, Yajun

    1998-09-01

    Accurate edge detection of retinal vessels is a prerequisite for quantitative analysis of subtle morphological changes of retinal vessels under different pathological conditions. A novel method for edge detection of retinal vessels is presented in this paper. Methods: (1) Wavelet-based image preprocessing. (2) The signed edge detection algorithm and mathematical morphological operation are applied to get the approximate regions that contain retinal vessels. (3) By convolving the preprocessed image with a LoG operator only on the detected approximate regions of retinal vessels, followed by edges refining, clear edge maps of the retinal vessels are fast obtained. Results: A detailed performance evaluation together with the existing techniques is given to demonstrate the strong features of our method. Conclusions: True edge locations of retinal vessels can be fast detected with continuous structures of retinal vessels, less non- vessel segments left and insensitivity to noise. The method is also suitable for other application fields such as road edge detection.

  9. Time-constrained project scheduling with adjacent resources

    NARCIS (Netherlands)

    Hurink, Johann L.; Kok, A.L.; Paulus, J.J.; Schutten, Johannes M.J.

    We develop a decomposition method for the Time-Constrained Project Scheduling Problem (TCPSP) with adjacent resources. For adjacent resources the resource units are ordered and the units assigned to a job have to be adjacent. On top of that, adjacent resources are not required by single jobs, but by

  10. Time-constrained project scheduling with adjacent resources

    NARCIS (Netherlands)

    Hurink, Johann L.; Kok, A.L.; Paulus, J.J.; Schutten, Johannes M.J.

    2008-01-01

    We develop a decomposition method for the Time-Constrained Project Scheduling Problem (TCPSP) with Adjacent Resources. For adjacent resources the resource units are ordered and the units assigned to a job have to be adjacent. On top of that, adjacent resources are not required by single jobs, but by

  11. Intravital two-photon microscopy of immune cell dynamics in corneal lymphatic vessels.

    Directory of Open Access Journals (Sweden)

    Philipp Steven

    Full Text Available BACKGROUND: The role of lymphatic vessels in tissue and organ transplantation as well as in tumor growth and metastasis has drawn great attention in recent years. METHODOLOGY/PRINCIPAL FINDINGS: We now developed a novel method using non-invasive two-photon microscopy to simultaneously visualize and track specifically stained lymphatic vessels and autofluorescent adjacent tissues such as collagen fibrils, blood vessels and immune cells in the mouse model of corneal neovascularization in vivo. The mouse cornea serves as an ideal tissue for this technique due to its easy accessibility and its inducible and modifiable state of pathological hem- and lymphvascularization. Neovascularization was induced by suture placement in corneas of Balb/C mice. Two weeks after treatment, lymphatic vessels were stained intravital by intrastromal injection of a fluorescently labeled LYVE-1 antibody and the corneas were evaluated in vivo by two-photon microscopy (TPM. Intravital TPM was performed at 710 nm and 826 nm excitation wavelengths to detect immunofluorescence and tissue autofluorescence using a custom made animal holder. Corneas were then harvested, fixed and analyzed by histology. Time lapse imaging demonstrated the first in vivo evidence of immune cell migration into lymphatic vessels and luminal transport of individual cells. Cells immigrated within 1-5.5 min into the vessel lumen. Mean velocities of intrastromal corneal immune cells were around 9 µm/min and therefore comparable to those of T-cells and macrophages in other mucosal surfaces. CONCLUSIONS: To our knowledge we here demonstrate for the first time the intravital real-time transmigration of immune cells into lymphatic vessels. Overall this study demonstrates the valuable use of intravital autofluorescence two-photon microscopy in the model of suture-induced corneal vascularizations to study interactions of immune and subsequently tumor cells with lymphatic vessels under close as possible

  12. ORNAMENTAL PLANTS OF CHECHNYA AND ITS ADJACENT AREAS

    Directory of Open Access Journals (Sweden)

    Musa A. Taysumov

    2018-01-01

    Full Text Available Abstract. The aim of the research is to summarize the scattered information about the types of decorative flora of the Chechen Republic and adjacent territories; to identify highly resistant ornamental plants for cities and settlements of the North Caucasus and other territories of Russia. Discussion. Currently, in a variety of botanical gardens of the North Caucasus grows a large number of decorative plant species, widely used in green construction. However, not all species posses the quality to sufficient resist unfavorable conditions of the changed abiotic and biotic environment. Among the studied, the most valuable and promising for widespread introduction are the species of more than 122 taxa, the decorative effect of which is preserved throughout the year with no signs of aging. Many examples of the targeted use of herbs, tree species, lianas, bulbous plants were cited in the research. We give a large list of Caucasian species for growing on lawns, flowerbeds, flower gardens, alpine and stony mountains, roadsides and parks, urban parks, squares and alleys as a type of gardening. Their decorative properties, vitality, durability, life form and other bio-ecological features, attitude to abiotic factors (soil conditions, illumination, temperature, soil and atmospheric humidification conditions, etc. were taken into account. Conclusion. We give a large list of ornamental species and various planting techniques of specific species are introduced in conditions of Chechnya and its adjacent territories as well as the methods of implementing in the landscaping practice in other (middle and northern regions of Russia.

  13. 76 FR 31351 - Safety Requirements and Manning Exemption Eligibility on Distant Water Tuna Fleet Vessels

    Science.gov (United States)

    2011-05-31

    ... DWTF vessel owner/operator may demonstrate such non-availability, namely by recounting the good faith... Authorization Act (CGAA, signed into law (Pub. L. 111-281) on October 15, 2010) reauthorized the use of foreign... wording ``to the extent practicable.'' However, since licensed positions often have contracts associated...

  14. ''Dural tail'' adjacent to a giant posterior cerebral artery aneurysm: case report and review of the literature

    International Nuclear Information System (INIS)

    Good, C.D.; Kingsley, D.P.E.; Taylor, W.J.; Harkness, W.F.

    1997-01-01

    The ''dural tail'' sign on gadolinium (Gd-DTPA)-enhanced MRI has been described in association with meningiomas. Various series with histopathological correlation have shown that in some cases there is tumour invasion into the dura mater, but in the majority of cases it represents a hypervascular, non-neoplastic reaction. While this sign was originally thought to be specific for meningioma, subsequent case reports have described the presence of a dural tail in other intra- and extra-axial lesions. We present a patient with a giant aneurysm arising from the P2 segment of the right posterior cerebral artery, adjacent to the tentorium, with a prominent dural tail on Gd-DTPA-enhanced MRI. In this location, differentiation of an aneurysm from a meningioma was critical. (orig.). With 2 figs

  15. On the domination and signed domination numbers of zero-divisor graph

    Directory of Open Access Journals (Sweden)

    Ebrahim Vatandoost

    2016-10-01

    Full Text Available Let $R$ be a commutative ring (with 1 and let $Z(R$ be its set of zero-divisors. The zero-divisor graph $\\Gamma(R$ has vertex set $Z^*(R=Z(R \\setminus \\lbrace0 \\rbrace$ and for distinct $x,y \\in Z^*(R$, the vertices $x$ and $y$ are adjacent if and only if $xy=0$. In this paper, we consider the domination number and signed domination number on zero-divisor graph $\\Gamma(R$ of commutative ring $R$ such that for every $0 \

  16. Large vessel involvement by IgG4-related disease

    Science.gov (United States)

    Perugino, Cory A.; Wallace, Zachary S.; Meyersohn, Nandini; Oliveira, George; Stone, James R.; Stone, John H.

    2016-01-01

    Abstract Objectives: IgG4-related disease (IgG4-RD) is an immune-mediated fibroinflammatory condition that can affect multiple organs and lead to tumefactive, tissue-destructive lesions. Reports have described inflammatory aortitis and periaortitis, the latter in the setting of retroperitoneal fibrosis (RPF), but have not distinguished adequately between these 2 manifestations. The frequency, radiologic features, and response of vascular complications to B cell depletion remain poorly defined. We describe the clinical features, radiology findings, and treatment response in a cohort of 36 patients with IgG4-RD affecting large blood vessels. Methods: Clinical records of all patients diagnosed with IgG4-RD in our center were reviewed. All radiologic studies were reviewed. We distinguished between primary large blood vessel inflammation and secondary vascular involvement. Primary involvement was defined as inflammation in the blood vessel wall as a principal focus of disease. Secondary vascular involvement was defined as disease caused by the effects of adjacent inflammation on the blood vessel wall. Results: Of the 160 IgG4-RD patients in this cohort, 36 (22.5%) had large-vessel involvement. The mean age at disease onset of the patients with large-vessel IgG4-RD was 54.6 years. Twenty-eight patients (78%) were male and 8 (22%) were female. Thirteen patients (36%) had primary IgG4-related vasculitis and aortitis with aneurysm formation comprised the most common manifestation. This affected 5.6% of the entire IgG4-RD cohort and was observed in the thoracic aorta in 8 patients, the abdominal aorta in 4, and both the thoracic and abdominal aorta in 3. Three of these aneurysms were complicated by aortic dissection or contained perforation. Periaortitis secondary to RPF accounted for 27 of 29 patients (93%) of secondary vascular involvement by IgG4-RD. Only 5 patients demonstrated evidence of both primary and secondary blood vessel involvement. Of those treated with

  17. Pulsed liquid jet dissector using holmium: YAG laser - a novel neurosurgical device for brain incision without imparing vessels

    International Nuclear Information System (INIS)

    Hirano, T.; Nakagawa, A.; Jokura, H.; Shirane, R.; Uenohara, H.; Ohyama, H.; Takayama, K.

    2003-01-01

    Neurosurgery has long required a method for dissecting brain tissue without damaging principal vessels and adjacent tissue, so as to prevent neurological complications after operation. In this study we constructed a prototype of such a device and used it in an attempt to resect beagle brain cortex. The prototype device consisted of an optical fiber, a Y adapter, and a nozzle whose internal exit diameter was 100 μm. Cold physiological saline (4 o C) was supplied to it at a rate of 40 ml/h. Pulsed liquid jets were ejected from the nozzle by a pulsed Holmium:YAG) (Ho:YAG) laser at an irradiation energy of 300 mJ/pulse. The profile of the liquid jet was observed with a high-speed camera while changing the distance between the optical fiber end and nozzle exit (equivalent to the Standoff distance). With this device (3 Hz operation), brain dissection of anesthetized beagles was attempted while measuring the local temperature of the target. A histological study of the incised parts was also performed. When the Standoff distance was 24 mm, the liquid jet was emitted straight from the nozzle at a maximum initial velocity of 50 m/s. The brain parenchyma was cut with this device while preserving vessels larger than 200 μm in diameter and keeping the operative field clear. The local temperature rose to no more than 41 o C, below the functional heat damage threshold of brain tissue. Histological findings showed no signs of thermal tissue damage around the dissected margin. The Ho:YAG laser-induced liquid jet dissector can be applied to neurosurgery after incorporating some minor improvements. (author)

  18. Remotely replaceable fuel and feed nozzles for the NWCF calciner vessel

    International Nuclear Information System (INIS)

    Fletcher, R.D.; Carter, J.A.; May, K.W.

    1978-01-01

    The development and testing of remotely replaceable fuel and feed nozzles for calcination of liquid radioactive wastes in the calciner vessel of the New Waste Calcining Facility (NWCF) being built at the Idaho National Engineering Laboratory are described. A complete fuel nozzle assembly was fabricated and tested at the Remote Maintenance Development Facility to evolve design refinements, identify required support equipment, and develop handling techniques. The design also provided for remote replacement of the nozzle support carriage and adjacent feed and fuel pipe loops using two pairs of master-slave manipulators

  19. Value of CT angiography in anterior circulation large vessel occlusive stroke: Imaging findings, pearls, and pitfalls

    Energy Technology Data Exchange (ETDEWEB)

    Power, Sarah, E-mail: drsarahpower@gmail.com [Department of Neuroradiology, Beaumont Hospital, P.O. Box 1297, Beaumont Rd, Dublin 9 (Ireland); McEvoy, Sinead H., E-mail: sineadmcevoy@beaumont.ie [Department of Neuroradiology, Beaumont Hospital, P.O. Box 1297, Beaumont Rd, Dublin 9 (Ireland); Cunningham, Jane, E-mail: janecunningham0708@gmail.com [Department of Radiology, Beaumont Hospital, P.O. Box 1297, Beaumont Rd, Dublin 9 (Ireland); Ti, Joanna P., E-mail: joannapearlyti@gmail.com [Department of Neuroradiology, Beaumont Hospital, P.O. Box 1297, Beaumont Rd, Dublin 9 (Ireland); Looby, Seamus, E-mail: seamuslooby@beaumont.ie [Department of Neuroradiology, Beaumont Hospital, P.O. Box 1297, Beaumont Rd, Dublin 9 (Ireland); O' Hare, Alan, E-mail: alanohare@beaumont.ie [Department of Neuroradiology, Beaumont Hospital, P.O. Box 1297, Beaumont Rd, Dublin 9 (Ireland); Williams, David, E-mail: davidwilliams@rcsi.ie [Department of Geriatrics and Stroke Medicine, Royal College of Surgeons in Ireland (RCSI) and Beaumont Hospital, P.O. Box 1297, Beaumont Rd, Dublin 9 (Ireland); Brennan, Paul, E-mail: paulbrennan@beaumont.ie [Department of Neuroradiology, Beaumont Hospital, P.O. Box 1297, Beaumont Rd, Dublin 9 (Ireland); Thornton, John, E-mail: johnthornton@beaumont.ie [Department of Neuroradiology, Beaumont Hospital, P.O. Box 1297, Beaumont Rd, Dublin 9 (Ireland)

    2015-07-15

    Highlights: • Site of occlusion determines potential collateralization routes and impacts outcome. • Multifocality of arterial occlusion is common, seen in approximately 20% of cases. • ICA false occlusion sign can be seen in setting of ICA stenosis or carotid T occlusion. • False patency sign: hyperdense thrombus/calcified occlusive plaque misinterpreted as patent vessel. • Additional abnormalities on CTA may infer stroke mechanism or alter decision making. - Abstract: Hyperacute stroke imaging is playing an increasingly important role in determining management decisions in acute stroke patients, particularly patients with large vessel occlusive stroke who may benefit from endovascular intervention. CT angiography (CTA) is an important tool in the work-up of the acute stroke patient. It reliably detects large occlusive thrombi in proximal cerebral arteries and is a quick and highly accurate method in identifying candidates for endovascular stroke treatment. In this article we review the imaging findings on CTA in acute large vessel occlusive stroke using a pictorial case based approach. We retrospectively reviewed CTA studies in 48 patients presenting with acute anterior circulation large vessel occlusive stroke who were brought for intra-arterial acute stroke intervention. We discuss and illustrate patterns of proximal intracranial arterial occlusion, collateralization to the occluded territory, as well as reviewing some important pearls, pitfalls and teaching points in CTA assessment of the acute stroke patient. Performed from the level of the aortic arch CTA also gives valuable information regarding the state of other vessels in the acute stroke patient, identifying additional significant vascular stenoses or occlusions, and as we illustrate, can demonstrate other clinically significant findings which may impact on patient management and outcome.

  20. Value of CT angiography in anterior circulation large vessel occlusive stroke: Imaging findings, pearls, and pitfalls

    International Nuclear Information System (INIS)

    Power, Sarah; McEvoy, Sinead H.; Cunningham, Jane; Ti, Joanna P.; Looby, Seamus; O'Hare, Alan; Williams, David; Brennan, Paul; Thornton, John

    2015-01-01

    Highlights: • Site of occlusion determines potential collateralization routes and impacts outcome. • Multifocality of arterial occlusion is common, seen in approximately 20% of cases. • ICA false occlusion sign can be seen in setting of ICA stenosis or carotid T occlusion. • False patency sign: hyperdense thrombus/calcified occlusive plaque misinterpreted as patent vessel. • Additional abnormalities on CTA may infer stroke mechanism or alter decision making. - Abstract: Hyperacute stroke imaging is playing an increasingly important role in determining management decisions in acute stroke patients, particularly patients with large vessel occlusive stroke who may benefit from endovascular intervention. CT angiography (CTA) is an important tool in the work-up of the acute stroke patient. It reliably detects large occlusive thrombi in proximal cerebral arteries and is a quick and highly accurate method in identifying candidates for endovascular stroke treatment. In this article we review the imaging findings on CTA in acute large vessel occlusive stroke using a pictorial case based approach. We retrospectively reviewed CTA studies in 48 patients presenting with acute anterior circulation large vessel occlusive stroke who were brought for intra-arterial acute stroke intervention. We discuss and illustrate patterns of proximal intracranial arterial occlusion, collateralization to the occluded territory, as well as reviewing some important pearls, pitfalls and teaching points in CTA assessment of the acute stroke patient. Performed from the level of the aortic arch CTA also gives valuable information regarding the state of other vessels in the acute stroke patient, identifying additional significant vascular stenoses or occlusions, and as we illustrate, can demonstrate other clinically significant findings which may impact on patient management and outcome

  1. Ultrastructure of Pericystic or Intracystic Blood Vessels in Epidermoid Cysts-A Transmission Electron Microscopy Study: Laboratory Investigation.

    Science.gov (United States)

    Ren, Xiao-Hui; Ma, Jun; Zeng, Chun; Sun, Yi-Lin; Lin, Song

    2017-07-01

    Recently, we reported a tendency toward spontaneous hemorrhage in both the preoperative and postoperative periods in patients with intracranial epidermoid cyst (EC). According to our experience, this tendency for spontaneous hemorrhage was partly caused by the pathologic blood vessels adjacent to the EC. This study was designed to testify this hypothesis. Twenty-three removable pericystic or intracystic blood vessels from 17 patients with EC were collected during surgery and were then examined by transmission electron microscopy. The microvascular structure in gliomas was chosen as the control. Under electron microscopy, variant pathologic changes of vessels were found in all patients with EC. In the tunicae intima, we found vacuolization, apoptosis, necrosis, and intralumenal protrusion of endothelial cells, as well as swollen basement and highly flexed and discontinued elastic plate. In the tunicae media, vacuolization and swollen mitochondria were found in muscular cells. In the tunicae adventitia, extravascular erythrocytes, edema or apoptosis of pericytes, collagen predominance, and inflammatory cell infiltration and destruction were found. Neuron denature and necrosis were found in the peripheral brain tissue. In the microvascular structure of 5 glioma specimens, we found enlargement and hyperplasia of endothelial cells, swollen basement membrane, swollen pericytes, and astrocytic hyperplasia and neuron denature in adjacent brain tissues. Our findings provide strong evidence for the hypothesis that intracystic or pericystic vascular degeneration or destruction accounts for the spontaneous hemorrhage tendency before and after surgical resection of ECs. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. A high-throughput platform for low-volume high-temperature/pressure sealed vessel solvent extractions

    Energy Technology Data Exchange (ETDEWEB)

    Damm, Markus [Christian Doppler Laboratory for Microwave Chemistry (CDLMC) and Institute of Chemistry, Karl-Franzens-University Graz, Heinrichstrasse 28, A-8010 Graz (Austria); Kappe, C. Oliver, E-mail: oliver.kappe@uni-graz.at [Christian Doppler Laboratory for Microwave Chemistry (CDLMC) and Institute of Chemistry, Karl-Franzens-University Graz, Heinrichstrasse 28, A-8010 Graz (Austria)

    2011-11-30

    Highlights: Black-Right-Pointing-Pointer Parallel low-volume coffee extractions in sealed-vessel HPLC/GC vials. Black-Right-Pointing-Pointer Extractions are performed at high temperatures and pressures (200 Degree-Sign C/20 bar). Black-Right-Pointing-Pointer Rapid caffeine determination from the liquid phase. Black-Right-Pointing-Pointer Headspace analysis of volatiles using solid-phase microextraction (SPME). - Abstract: A high-throughput platform for performing parallel solvent extractions in sealed HPLC/GC vials inside a microwave reactor is described. The system consist of a strongly microwave-absorbing silicon carbide plate with 20 cylindrical wells of appropriate dimensions to be fitted with standard HPLC/GC autosampler vials serving as extraction vessels. Due to the possibility of heating up to four heating platforms simultaneously (80 vials), efficient parallel analytical-scale solvent extractions can be performed using volumes of 0.5-1.5 mL at a maximum temperature/pressure limit of 200 Degree-Sign C/20 bar. Since the extraction and subsequent analysis by either gas chromatography or liquid chromatography coupled with mass detection (GC-MS or LC-MS) is performed directly from the autosampler vial, errors caused by sample transfer can be minimized. The platform was evaluated for the extraction and quantification of caffeine from commercial coffee powders assessing different solvent types, extraction temperatures and times. For example, 141 {+-} 11 {mu}g caffeine (5 mg coffee powder) were extracted during a single extraction cycle using methanol as extraction solvent, whereas only 90 {+-} 11 were obtained performing the extraction in methylene chloride, applying the same reaction conditions (90 Degree-Sign C, 10 min). In multiple extraction experiments a total of {approx}150 {mu}g caffeine was extracted from 5 mg commercial coffee powder. In addition to the quantitative caffeine determination, a comparative qualitative analysis of the liquid phase coffee

  3. Sign Lowering and Phonetic Reduction in American Sign Language.

    Science.gov (United States)

    Tyrone, Martha E; Mauk, Claude E

    2010-04-01

    This study examines sign lowering as a form of phonetic reduction in American Sign Language. Phonetic reduction occurs in the course of normal language production, when instead of producing a carefully articulated form of a word, the language user produces a less clearly articulated form. When signs are produced in context by native signers, they often differ from the citation forms of signs. In some cases, phonetic reduction is manifested as a sign being produced at a lower location than in the citation form. Sign lowering has been documented previously, but this is the first study to examine it in phonetic detail. The data presented here are tokens of the sign WONDER, as produced by six native signers, in two phonetic contexts and at three signing rates, which were captured by optoelectronic motion capture. The results indicate that sign lowering occurred for all signers, according to the factors we manipulated. Sign production was affected by several phonetic factors that also influence speech production, namely, production rate, phonetic context, and position within an utterance. In addition, we have discovered interesting variations in sign production, which could underlie distinctions in signing style, analogous to accent or voice quality in speech.

  4. Percutaneous Retrieval of Foreign Bodies Around Vital Vessels Aided with Vascular Intervention: A Technical Note

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Xiu-Jun, E-mail: woothingyang2008@126.com [Shanghai Eighth People’s Hospital, Department of Radiology (China); Xing, Guang-Fu, E-mail: xgf8848@126.com [Shanghai Eighth People’s Hospital, Department of General Surgery (China)

    2015-10-15

    ObjectiveTo describe a new interventional technique to remove foreign bodies (FBs) embedded in soft tissues around vital vessels.MethodsUnder fluoroscopic guidance and using local anesthesia, percutaneous removal of FBs was performed using forceps in nine patients. All patients suffered from a metallic soft tissue FB located in close proximity to important vessels and one also had a small traumatic pseudoaneurysm adjacent to the FB. Prior to removal of the FB, the position of the nearest vessel was identified using a guide wire or catheter placed into the vessel. Balloon catheter was also simultaneously used to temporarily stop the blood flow of the nearest artery during the FB removal in three of the nine patients.ResultsAll of the nine FBs with 0–2 mm interval to the nearest vessel were successfully removed in the nine patients without any serious complications. The removed FBs measured 3–12 mm in length and 1–3 mm in width. The total fluoroscopic time of retrieval of each FB was 5–9 min (mean, 6.4 min). The volume of intraoperative bleeding ranged from 5 to 12 ml (mean, 7.5 ml). The length of hospital stay for each patient ranged from 4 to 8 days (mean, 5.5 days).ConclusionVascular intervention-aided percutaneous FB removal is minimally invasive and an effective method for removal of FBs around vital vessels.

  5. Primo vessel inside a lymph vessel emerging from a cancer tissue.

    Science.gov (United States)

    Lee, Sungwoo; Ryu, Yeonhee; Cha, Jinmyung; Lee, Jin-Kyu; Soh, Kwang-Sup; Kim, Sungchul; Lim, Jaekwan

    2012-10-01

    Primo vessels were observed inside the lymph vessels near the caudal vena cava of a rabbit and a rat and in the thoracic lymph duct of a mouse. In the current work we found a primo vessel inside the lymph vessel that came out from the tumor tissue of a mouse. A cancer model of a nude mouse was made with human lung cancer cell line NCI-H460. We injected fluorescent nanoparticles into the xenografted tumor tissue and studied their flow in blood, lymph, and primo vessels. Fluorescent nanoparticles flowed through the blood vessels quickly in few minutes, and but slowly in the lymph vessels. The bright fluorescent signals of nanoparticles disappeared within one hour in the blood vessels but remained much longer up to several hours in the case of lymph vessels. We found an exceptional case of lymph vessels that remained bright with fluorescence up to 24 hours. After detailed examination we found that the bright fluorescence was due to a putative primo vessel inside the lymph vessel. This rare observation is consistent with Bong-Han Kim's claim on the presence of a primo vascular system in lymph vessels. It provides a significant suggestion on the cancer metastasis through primo vessels and lymph vessels. Copyright © 2012. Published by Elsevier B.V.

  6. Low-frequency oscillations and vasoreactivity of cortical vessels in obstructive sleep apnea during wakefulness

    DEFF Research Database (Denmark)

    Schytz, Henrik Winther; Jensen, Benedicte Ersted; Jennum, Poul

    2013-01-01

    Effective nasal continuous positive airway pressure (CPAP) therapy reduces the cardiovascular outcomes associated with obstructive sleep apnea (OSA), but the mechanism behind this effect is unclear. We investigated if OSA patients during wakefulness showed signs of increased sympathetic activity...... and decreased vasoreactivity in cerebral cortical vessels as measured with near-infrared spectroscopy (NIRS), and if this may be reversed by CPAP treatment....

  7. Spondylolisthesis adjacent to a cervical disc arthroplasty does not increase the risk of adjacent level degeneration.

    Science.gov (United States)

    Kieser, David Christopher; Cawley, Derek Thomas; Roscop, Cecile; Mazas, Simon; Coudert, Pierre; Boissiere, Louis; Obeid, Ibrahim; Vital, Jean-Marc; Pointillart, Vincent; Gille, Olivier

    2018-03-31

    To understand whether a spondylolisthesis in the sub-axial spine cranial to a cervical disc arthroplasty (CDA) construes a risk of adjacent level disease (ALD). A retrospective review of 164 patients with a minimum 5-year follow-up of a cervical disc arthroplasty was performed. Multi-level surgeries, including hybrid procedures, were included. Multiple implant types were included. The two inter-vertebral discs (IVD) cranial of the CDA were monitored for evidence of radiologic degeneration using the Kettler criteria. The rate of ALD in CDA found in this series was 17.8%, with most affecting the immediately adjacent IVD (27.4 and 7.6%, respectively p = 0.000). Pre-operative mild spondylolisthesis adjacent to a planned CDA was not found to be a risk factor for ALD within 5 years. Those with a degenerative spondylolisthesis are at higher risk of ALD (33%) than those with a non-degenerative cause for their spondylolisthesis (11%). Post-operative CDA alignment, ROM or induced spondylolisthesis do not affect the rate of ALD in those with an adjacent spondylolisthesis. Patients with ALD experience significantly worse 5-year pain and functional outcomes than those unaffected by ALD. A pre-operatively identified mild spondylolisthesis in the sub-axial spine cranially adjacent to a planned CDA is not a risk factor for ALD within 5 years. These slides can be retrieved under Electronic Supplementary Material.

  8. Magnetic field control of 90 Degree-Sign , 180 Degree-Sign , and 360 Degree-Sign domain wall resistance

    Energy Technology Data Exchange (ETDEWEB)

    Majidi, Roya, E-mail: royamajidi@gmail.com [Department of Physics, Shahid Rajaee Teacher Training University, Lavizan, 16788-15811 Tehran (Iran, Islamic Republic of)

    2012-10-01

    In the present work, we have compared the resistance of the 90 Degree-Sign , 180 Degree-Sign , and 360 Degree-Sign domain walls in the presence of external magnetic field. The calculations are based on the Boltzmann transport equation within the relaxation time approximation. One-dimensional Neel-type domain walls between two domains whose magnetization differs by angle of 90 Degree-Sign , 180 Degree-Sign , and 360 Degree-Sign are considered. The results indicate that the resistance of the 360 Degree-Sign DW is more considerable than that of the 90 Degree-Sign and 180 Degree-Sign DWs. It is also found that the domain wall resistance can be controlled by applying transverse magnetic field. Increasing the strength of the external magnetic field enhances the domain wall resistance. In providing spintronic devices based on magnetic nanomaterials, considering and controlling the effect of domain wall on resistivity are essential.

  9. Stress-rupture lifetimes of organic fiber-epoxy strands and pressure vessels

    International Nuclear Information System (INIS)

    Hahn, H.T.; Chiu, I.L.; Gates, T.L.

    1979-01-01

    Long-term behavior of filament-wound pressure vessels were tested, Kevlar 49 epoxy strands were studied in stress-rupture for more than a year. Because the strands are the smallest structural unit in filament winding, their behavior directly controls the performance of vessels. Five different stress levels were studied: 86, 80, 74, 68, and 50% of the mean ultimate tensile strength (UTS). At each stress level, approximately one-hundred strands were hung in a room maintained at 22 to 24 0 C and below 20% relative humidity. Failure times were automatically recorded by a data acquisition system. Lifetimes were analyzed statistically using a two-parameter Weibull distribution. The maximum-likelihood method was used to estimate the parameters. The shape parameter, which is a measure of scatter and failure-rate change, increased with decreasing stress level. Less scatter and increasing failure rates were observed at lower stresses. There was no sign of an endurance limit down to 68% UTS. At 50% UTS no failure had yet occurred after 9000 h. The strand data were compared with data on lifetimes of pressure vessels wound with the same fiber and epoxy. The strands had slightly longer characteristic lifetimes, except at 86% UTS, and slightly less scatter, except at 68% UTS. The results of this study indicate that strands can provide valuable information about the long-term performance of filament-wound pressure vessels

  10. Dermoscopic findings in scalp psoriasis and seborrheic dermatitis; Two new signs; Signet ring vessel and hidden hair

    Directory of Open Access Journals (Sweden)

    Melike Kibar

    2015-01-01

    Full Text Available Background: Psoriasis and seborrheic dermatitis are both chronic erythemato-squamous dermatoses that can involve the scalp. It may be difficult to differentiate these two diseases when there is isolated scalp involvement. Recently, trichoscopy is commonly used to differentiate noncicatricial alopecias including psoriasis and seborrheic dermatitis that can lead to telogen effluvium (TE. Objectives: The objective of this study is to evaluate the trichoscopic figures that may help to differentiate scalp psoriasis and seborrheic dermatitis. Materials and Methods: Thirty one with scalp psoriasis and 112 patients with seborrheic dermatitis were enrolled. Trichoscopic examinations were performed using a videodermatoscope (MoleMax 3 ® . Trichoscopic findings of scalp psoriasis and seborrheic dermatitis were compared with each other, with 100 healthy individuals and with other noncicatricial alopecias including female androgenetic alopecia (FAGA (n: 138, male androgenetic alopecia (n: 63, FAGA of male pattern (FAGA.M (n: 5, alopecia areata (39, TE (n: 22 and trichotillomania (n: 4. Results: Atypical red vessels, red dots and globules (RDG, signet ring vessels (SRV, structureless red areas and hidden hairs (HH were statistically more common in psoriasis while twisted red loops and comma vessels (CV in seborrheic dermatitis. RDG were considered as the characteristic videodermatoscopic figure for psoriasis and arborizing red lines and CV for seborrheic dermatitis. In comparison with previous reports, our study yielded two new trichoscopic structures supporting the diagnosis of psoriasis; HH and SRV. Besides, according to our study, CV were described for the first time in seborrheic dermatitis and considered to be specific for seborrheic dermatitis. Conclusion: This study confirmed that trichoscopy might be useful in differentiating scalp psoriasis and seborrheic dermatitis from each other and from other noncicatricial alopecia with three trichoscopic

  11. Dynamic response of the JT-60 vacuum vessel under the electromagnetic forces

    International Nuclear Information System (INIS)

    Takatsu, H.; Shimizu, M.; Ohta, M.

    1982-01-01

    Dynamic response analyses of the JAERI Tokamak 60 (JT-60) vacuum vessel were carried out under three kinds of saddle-like electromagnetic forces. In the analysis, the dynamic response of the bellows was obtained by dividing it into three components; the first, caused by the forced deflection due to the displacement of an adjacent rigid ring; the second, caused by inertia force; and the third, caused by a saddle-like electromagnetic force. Eigenvalue analyses showed that the 20th mode is a typical rotation mode of the rigid ring around the major radius with a natural frequency of 46.3 Hz. From the results of the dynamic response analyses, the maximum displacement response of the rigid ring was 3.1 mm and remarkable dynamic response was observed in the case of plasma disruption with a time constant of 1 ms. In cases of start-up of the plasma current and plasma disruption with a time constant of 50 ms, the rigid ring vibrates quasi-statically. It is clear that the dynamic behavior of the vacuum vessel is governed mainly by the saddle-like electromagnetic force, with a smaller effect of the inverse saddle-like electromagnetic force on the dynamic response of the vacuum vessel. (orig.)

  12. Seatbelt sign in a case of blunt abdominal trauma; what lies beneath it?

    Science.gov (United States)

    Vailas, Michail G; Moris, Demetrios; Orfanos, Stamatios; Vergadis, Chrysovalantis; Papalampros, Alexandros

    2015-10-30

    The reported incidence of hollow viscus injuries (HVI) in blunt trauma patients is approximately 1%. The most common site of injury to the intestine in blunt abdominal trauma (BAT) is the small bowel followed by colon, with mesenteric injuries occurring three times more commonly than bowel injuries. Isolated colon injury is a rarely encountered condition. Clinical assessment alone in patients with suspected intestinal or mesenteric injury after blunt trauma is associated with unacceptable diagnostic delays. This is a case of a 31-year-old man, admitted to the emergency department after being the restrained driver, involved in a car accident. After initial resuscitation, focused assessment with sonography for trauma examination (FAST) was performed revealing a subhepatic mass, suspicious for intraperitoneal hematoma. A computed tomography scan (CT) that followed showed a hematoma of the mesocolon of the ascending colon with active extravasation of intravenous contrast material. An exploratory laparotomy was performed, hemoperitomeum was evacuated, and a subserosal hematoma of the cecum and ascending colon with areas of totally disrupted serosal wall was found. Hematoma of the adjacent mesocolon expanding to the root of mesenteric vessels was also noted. A right hemicolectomy along with primary ileocolonic anastomosis was performed. Patient's recovery progressed uneventfully. Identifying an isolated traumatic injury to the bowel or mesentery after BAT can be a clinical challenge because of its subtle and nonspecific clinical findings; meeting that challenge may eventually lead to a delay in diagnosis and treatment with subsequent increase in associated morbidity and mortality. Isolated colon injury is a rare finding after blunt trauma and usually accompanied by other intra-abdominal organ injuries. Abdominal 'seatbelt' sign, ecchymosis of the abdominal wall, increasing abdominal pain and distension are all associated with HVI. However, the accuracy of these findings

  13. Development of glia and blood vessels in the internal capsule of rats.

    Science.gov (United States)

    Earle, K L; Mitrofanis, J

    1998-02-01

    We have explored two aspects of internal capsule development that have not been described previously, namely, the development of glia and of blood vessels. To these ends, we used antibodies to glial fibrillary acidic protein (GFAP) and to vimentin (to identify astrocytes and to radial glia) and Griffonia simplicifolia (lectin; to identify microglia and blood vessels). Further, we made intracardiac injections of Evans Blue to examine the permeability of this dye in the vessels of the internal capsule during neonatal development. Our results show that large numbers of radial glia, astrocytes and microglia are not labelled with these markers in the white matter of the internal capsule until about birth; very few are labelled earlier, during the critical stages of corticofugal and corticopetal axonal ingrowth (E15-E20). The large glial labelling in the internal capsule at birth is accompanied by a dense vascular innervation of the capsule; as with the glia, very few labelled patent vessels are seen earlier. After intracardiac injections of Evans Blue, we find that the blood vessels of the internal capsule are not particularly permeable to Evans Blue. At each age examined (P0, P5, P15), blood vessels are outlined very clearly and there is no diffuse haze of fluorescence within the extracellular space, which is indicative of a leaky vessel. There are three striking differences between the glial environment of the internal capsule and that of the adjacent thalamus. First, the internal capsule is never rich with radial glial fibres (vimentin- and GFAP-immunoreactive) during development (except at P0), whereas the thalamus has many radial fibres from very early development (E15-E17). Second, astrocytes (vimentin- and GFAP-immunoreactive) first become apparent in the internal capsule (E20-P0) well before they do in the thalamus (P15). Third, the internal capsule houses a large transient population of amoeboid microglia (P0-P22), whereas the thalamus does not; only ramified

  14. Evaluation for In-Vessel Retention Capabilities with In-Vessel Injection and External Reactor Vessel Cooling

    International Nuclear Information System (INIS)

    Lee, Jeong Seong; Ryu, In Chul; Moon, Young Tae

    2016-01-01

    If the accident has not progressed to the point of substantial changes in the core geometry, establishing adequate cooling is as straightforward as re-establishing flow through the reactor core. However, if the accident has progressed to the point where the core geometry is substantially altered as a result of material melting and relocation, as was the case in the TMI-2 accident, the means of cooling the debris are not as straightforward. From this time on, the reactor core was either completely or nearly covered by water, with high pressure injection flow initiated shortly after three hours into the accident. However, the core debris was not coolable in this configuration and a substantial quantity of molten core material drained into the bypass region, with approximately twenty metric tons of molten debris draining into the reactor pressure vessel (RPV) lower head. Hence, the core configuration developed at approximately three hours into the accident was not coolable, even submerged in water. The purpose of this paper is to evaluate in-vessel retention capabilities with in-vessel injection (IVI) and external reactor vessel cooling (ERVC) available in a reactor application by using the integrated severe accident analysis code. The MAAP5 models were improved to facilitate evaluation of the in-vessel retention capability of APR1400. In-vessel retention capabilities have been analyzed for the APR1400 using the MAAP5.03 code. The results show that in-vessel retention is feasible when in-vessel injection is initiated within a relatively short time frame under the simulation condition used in the present study

  15. Evaluation for In-Vessel Retention Capabilities with In-Vessel Injection and External Reactor Vessel Cooling

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jeong Seong; Ryu, In Chul; Moon, Young Tae [KEPCO Engineering and Construction Co. Ltd., Deajeon (Korea, Republic of)

    2016-10-15

    If the accident has not progressed to the point of substantial changes in the core geometry, establishing adequate cooling is as straightforward as re-establishing flow through the reactor core. However, if the accident has progressed to the point where the core geometry is substantially altered as a result of material melting and relocation, as was the case in the TMI-2 accident, the means of cooling the debris are not as straightforward. From this time on, the reactor core was either completely or nearly covered by water, with high pressure injection flow initiated shortly after three hours into the accident. However, the core debris was not coolable in this configuration and a substantial quantity of molten core material drained into the bypass region, with approximately twenty metric tons of molten debris draining into the reactor pressure vessel (RPV) lower head. Hence, the core configuration developed at approximately three hours into the accident was not coolable, even submerged in water. The purpose of this paper is to evaluate in-vessel retention capabilities with in-vessel injection (IVI) and external reactor vessel cooling (ERVC) available in a reactor application by using the integrated severe accident analysis code. The MAAP5 models were improved to facilitate evaluation of the in-vessel retention capability of APR1400. In-vessel retention capabilities have been analyzed for the APR1400 using the MAAP5.03 code. The results show that in-vessel retention is feasible when in-vessel injection is initiated within a relatively short time frame under the simulation condition used in the present study.

  16. Multi-atlas pancreas segmentation: Atlas selection based on vessel structure.

    Science.gov (United States)

    Karasawa, Ken'ichi; Oda, Masahiro; Kitasaka, Takayuki; Misawa, Kazunari; Fujiwara, Michitaka; Chu, Chengwen; Zheng, Guoyan; Rueckert, Daniel; Mori, Kensaku

    2017-07-01

    Automated organ segmentation from medical images is an indispensable component for clinical applications such as computer-aided diagnosis (CAD) and computer-assisted surgery (CAS). We utilize a multi-atlas segmentation scheme, which has recently been used in different approaches in the literature to achieve more accurate and robust segmentation of anatomical structures in computed tomography (CT) volume data. Among abdominal organs, the pancreas has large inter-patient variability in its position, size and shape. Moreover, the CT intensity of the pancreas closely resembles adjacent tissues, rendering its segmentation a challenging task. Due to this, conventional intensity-based atlas selection for pancreas segmentation often fails to select atlases that are similar in pancreas position and shape to those of the unlabeled target volume. In this paper, we propose a new atlas selection strategy based on vessel structure around the pancreatic tissue and demonstrate its application to a multi-atlas pancreas segmentation. Our method utilizes vessel structure around the pancreas to select atlases with high pancreatic resemblance to the unlabeled volume. Also, we investigate two types of applications of the vessel structure information to the atlas selection. Our segmentations were evaluated on 150 abdominal contrast-enhanced CT volumes. The experimental results showed that our approach can segment the pancreas with an average Jaccard index of 66.3% and an average Dice overlap coefficient of 78.5%. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Remotely replaceable fuel and feed nozzles for the new waste calcining facility calciner vessel

    International Nuclear Information System (INIS)

    Fletcher, R.D.; Carter, J.A.; May, K.W.

    1978-01-01

    The development and testing of remotely replaceable fuel and feed nozzles for calcination of liquid radioactive wastes in the calciner vessel of the New Waste Calcining Facility being built at the Idaho National Engineering Laboratory is described. A complete fuel nozzle assembly was fabricated and tested at the Remote Maintenance Development Facility to evolve design refinements, identify required support equipment, and develop handling techniques. The design also provided for remote replacement of the nozzle support carriage and adjacent feed and fuel pipe loops using two pairs of master-slave manipulators

  18. Metacarpal sign

    Directory of Open Access Journals (Sweden)

    Barbara Nieradko-Iwanicka

    2018-02-01

    Full Text Available Background Archibald's sign, or metacarpal sign is defined as shortening of the IV and V metacarpal bones, is a rare phenomenon found in the Turner syndrome, homocystinuria and in Albright's osteodystrophy. Objectives The aim of the article was to show a rare case of metacarpal sign with atypical shortening of the III and IV metacarpal bones not connected with gonadal dysgenesia, genetic disorders nor osteodystrophy. Material and methods Case report of a 60-year-old female patient. Results Artchibald's metacarpal sign in the described case was accompanied by erosive arthritis in the left lower extremity. No features of genetic disorders nor gonadal disgenesia were found in the patient. Undifferentiated seronegative asymmetric erosive arthritis developed in the patient. The level of parathormon was within the normal range. No signs of tumor were seen in bone scintigraphy. Conclusions Archibald's metacarpal sign may be present in patients without genetic disorders.

  19. Ergonomics and design: traffic sign and street name sign.

    Science.gov (United States)

    Moroni, Janaina Luisa da Silva; Aymone, José Luís Farinatti

    2012-01-01

    This work proposes a design methodology using ergonomics and anthropometry concepts applied to traffic sign and street name sign projects. Initially, a literature revision on cognitive ergonomics and anthropometry is performed. Several authors and their design methodologies are analyzed and the aspects to be considered in projects of traffic and street name signs are selected and other specific aspects are proposed for the design methodology. A case study of the signs of "Street of Antiques" in Porto Alegre city is presented. To do that, interviews with the population are made to evaluate the current situation of signs. After that, a new sign proposal with virtual prototyping is done using the developed methodology. The results obtained with new interviews about the proposal show the user satisfaction and the importance of cognitive ergonomics to development of this type of urban furniture.

  20. Sign language comprehension: the case of Spanish sign language.

    Science.gov (United States)

    Rodríguez Ortiz, I R

    2008-01-01

    This study aims to answer the question, how much of Spanish Sign Language interpreting deaf individuals really understand. Study sampling included 36 deaf people (deafness ranging from severe to profound; variety depending on the age at which they learned sign language) and 36 hearing people who had good knowledge of sign language (most were interpreters). Sign language comprehension was assessed using passages of secondary level. After being exposed to the passages, the participants had to tell what they had understood about them, answer a set of related questions, and offer a title for the passage. Sign language comprehension by deaf participants was quite acceptable but not as good as that by hearing signers who, unlike deaf participants, were not only late learners of sign language as a second language but had also learned it through formal training.

  1. Multiple shell pressure vessel

    International Nuclear Information System (INIS)

    Wedellsborg, B.W.

    1988-01-01

    A method is described of fabricating a pressure vessel comprising the steps of: attaching a first inner pressure vessel having means defining inlet and outlet openings to a top flange, placing a second inner pressure vessel, having means defining inlet and outlet opening, concentric with and spaced about the first inner pressure vessel and attaching the second inner pressure vessel to the top flange, placing an outer pressure vessel, having inlet and outlet openings, concentric with and spaced apart about the second inner pressure vessel and attaching the outer pressure vessel to the top flange, attaching a generally cylindrical inner inlet conduit and a generally cylindrical inner outlet conduit respectively to the inlet and outlet openings in the first inner pressure vessel, attaching a generally cylindrical outer inlet conduit and a generally cylindrical outer outlet conduit respectively to the inlet and outlet opening in the second inner pressure vessel, heating the assembled pressure vessel to a temperature above the melting point of a material selected from the group, lead, tin, antimony, bismuth, potassium, sodium, boron and mixtures thereof, filling the space between the first inner pressure vessel and the second inner pressure vessel with material selected from the group, filling the space between the second inner pressure vessel and the outer pressure vessel with material selected from the group, and pressurizing the material filling the spaces between the pressure vessels to a predetermined pressure, the step comprising: pressurizing the spaces to a pressure whereby the wall of the first inner pressure vessel is maintained in compression during steady state operation of the pressure vessel

  2. Headaches - danger signs

    Science.gov (United States)

    Migraine headache - danger signs; Tension headache - danger signs; Cluster headache - danger signs; Vascular headache - danger signs ... and other head pain. In: Goldman L, Schafer AI, eds. Goldman-Cecil Medicine . 25th ed. Philadelphia, PA: ...

  3. 33 CFR 90.3 - Pushing vessel and vessel being pushed: Composite unit.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Pushing vessel and vessel being... HOMELAND SECURITY INLAND NAVIGATION RULES INLAND RULES: INTERPRETATIVE RULES § 90.3 Pushing vessel and vessel being pushed: Composite unit. Rule 24(b) of the Inland Rules states that when a pushing vessel and...

  4. 33 CFR 82.3 - Pushing vessel and vessel being pushed: Composite unit.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Pushing vessel and vessel being... HOMELAND SECURITY INTERNATIONAL NAVIGATION RULES 72 COLREGS: INTERPRETATIVE RULES § 82.3 Pushing vessel and vessel being pushed: Composite unit. Rule 24(b) of the 72 COLREGS states that when a pushing vessel and a...

  5. Sign language typology: The contribution of rural sign languages

    NARCIS (Netherlands)

    de Vos, C.; Pfau, R.

    2015-01-01

    Since the 1990s, the field of sign language typology has shown that sign languages exhibit typological variation at all relevant levels of linguistic description. These initial typological comparisons were heavily skewed toward the urban sign languages of developed countries, mostly in the Western

  6. The pretzel sign: angiographic pattern of tortuous intra-aneurysmal blood flow in a giant serpentine aneurysm.

    LENUS (Irish Health Repository)

    Fanning, N F

    2012-02-03

    Giant serpentine aneurysms (GSAs) form a specific subgroup of giant cerebral aneurysms that have pathognomonic angiographic features. We report the angiographic findings of a GSA demonstrating a striking convoluted dynamic flow pattern, which we have called the \\'pretzel sign\\'. The aneurysm was successfully treated by permanent occlusion of the parent vessel using a detachable balloon. GSAs should be identified prior to treatment in view of their particular management requirements.

  7. Malaysian sign language dataset for automatic sign language ...

    African Journals Online (AJOL)

    Journal of Fundamental and Applied Sciences. Journal Home · ABOUT ... SL recognition system based on the Malaysian Sign Language (MSL). Implementation results are described. Keywords: sign language; pattern classification; database.

  8. Vessel Operator System

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Operator cards are required for any operator of a charter/party boat and or a commercial vessel (including carrier and processor vessels) issued a vessel permit from...

  9. Size ratio performance in detecting cerebral aneurysm rupture status is insensitive to small vessel removal.

    Science.gov (United States)

    Lauric, Alexandra; Baharoglu, Merih I; Malek, Adel M

    2013-04-01

    The variable definition of size ratio (SR) for sidewall (SW) vs bifurcation (BIF) aneurysms raises confusion for lesions harboring small branches, such as carotid ophthalmic or posterior communicating locations. These aneurysms are considered SW by many clinicians, but SR methodology classifies them as BIF. To evaluate the effect of ignoring small vessels and SW vs stringent BIF labeling on SR ruptured aneurysm detection performance in borderline aneurysms with small branches, and to reconcile SR-based labeling with clinical SW/BIF classification. Catheter rotational angiographic datasets of 134 consecutive aneurysms (60 ruptured) were automatically measured in 3-dimensional. Stringent BIF labeling was applied to clinically labeled aneurysms, with 21 aneurysms switching label from SW to BIF. Parent vessel size was evaluated both taking into account, and ignoring, small vessels. SR was defined accordingly as the ratio between aneurysm and parent vessel sizes. Univariate and multivariate statistics identified significant features. The square of the correlation coefficient (R(2)) was reported for bivariate analysis of alternative SR calculations. Regardless of SW/BIF labeling method, SR was equally significant in discriminating aneurysm ruptured status (P analysis of alternative SR had a high correlation of R(2) = 0.94 on the whole dataset, and R = 0.98 on the 21 borderline aneurysms. Ignoring small branches from SR calculation maintains rupture status detection performance, while reducing postprocessing complexity and removing labeling ambiguity. Aneurysms adjacent to these vessels can be considered SW for morphometric analysis. It is reasonable to use the clinical SW/BIF labeling when using SR for rupture risk evaluation.

  10. Comprehending the structure of a vacuum vessel and in-vessel components of fusion machines. 1. Comprehending the vacuum vessel structure

    International Nuclear Information System (INIS)

    Onozuka, Masanori; Nakahira, Masataka

    2006-01-01

    The functions, conditions and structure of vacuum vessel using tokamak fusion machines are explained. The structural standard and code of vacuum vessel, process of vacuum vessel design, and design of ITER vacuum vessel are described. Production and maintenance of ultra high vacuum, confinement of radioactive materials, support of machines in vessel and electromagnetic force, radiation shield, plasma vertical stability, one-turn electric resistance, high temperature baking heat and remove of nuclear heat, reduce of troidal ripple, structural standard, features of safety of nuclear fusion machines, subjects of structural standard of fusion vacuum vessel, design flow of vacuum vessel, establishment of radial build, selections of materials, baking and cooling method, basic structure, structure of special parts, shield structure, and of support structure, and example of design of structure, ITER, are stated. (S.Y.)

  11. Images in pediatrics: the thymic sail sign and thymic wave sign.

    Science.gov (United States)

    Alves, Nuno D; Sousa, Marta

    2013-01-01

    The authors present a radiographic image portraying the "thymic sail sign" and the "thymic wave sign," both normal findings in infant radiographs and present a short description of these signs. These are distinguished from pathologic findings such as the "spinnaker-sail sign" in pneumomediastinum.

  12. An Experimental Study to Replace the Thoracic Descending Aorta for Pigs with a Self-Made Sutureless Blood Vessel

    Directory of Open Access Journals (Sweden)

    Fenglin Song

    2014-01-01

    Full Text Available To simplify the procedure of blood vessel replacement operation and shorten the vascular anastomosis time, we developed a special artificial blood vessel which can be connected to native blood vessels without suture. The self-made sutureless blood vessel (SMSBV was made from two titanium connectors and a Gore-Tex graft. To investigate blood compatibility and histocompatibility of the SMSBV, we carried thoracic descending aorta replacement using either SMSBV or Gore-Tex, respectively, in pigs. The aortic clamp time and the operative blood loss in the experimental group (using SMSBV were less than those in the control group (using Gore-Tex. The whole blood hematocrit, platelet count, plasma soluble P-selectin, plasma free hemoglobin, and interleukins 2, 6 at each time point were not different significantly between the two groups. Light microscopy and transmission electron microscopy examination showed there were layers of vascular smooth muscle cells and endothelial cells adhered in the inner wall of artificial blood vessel without any signs of thrombosis. Based on the result, we have drawn the conclusion that the application of SMSBV can significantly shorten the vascular anastomosis time, reduce operative blood loss, and show good blood and tissue compatibility.

  13. Conjugate heat transfer analysis for in-vessel retention with external reactor vessel cooling

    International Nuclear Information System (INIS)

    Park, Jong-Woon; Bae, Jae-ho; Song, Hyuk-Jin

    2016-01-01

    Highlights: • A conjugate heat transfer analysis method is applied for in-vessel corium retention. • 3D heat diffusion has a formidable effect in alleviating focusing heat load from metallic layer. • The focusing heat load is decreased by about 2.5 times on the external surface. - Abstract: A conjugate heat transfer analysis method for the thermal integrity of a reactor vessel under external reactor vessel cooling conditions is developed to resolve light metal layer focusing effect issue for in-vessel retention. The method calculates steady-state three-dimensional temperature distribution of a reactor vessel using coupled conjugate heat transfer between in-vessel three-layered stratified corium (metallic pool, oxide pool and heavy metal and polar-angle dependent boiling heat transfer at the outer surface of a reactor vessel). The three-layer corium heat transfer model is utilizing lumped-parameter thermal-resistance circuit method. For the ex-vessel boiling boundary conditions, nucleate, transition and film boiling are considered. The thermal integrity of a reactor vessel is addressed in terms of heat flux at the outer-most nodes of the vessel and remaining thickness profile. The vessel three-dimensional heat conduction is validated against a commercial code. It is found that even though the internal heat flux from the metal layer goes far beyond critical heat flux (CHF) the heat flux from the outermost nodes of the vessel may be maintained below CHF due to massive vessel heat diffusion. The heat diffusion throughout the vessel is more pronounced for relatively low heat generation rate in an oxide pool. Parametric calculations are performed considering thermal conditions such as peak heat flux from a light metal layer, heat generation in an oxide pool and external boiling conditions. The major finding is that the most crucial factor for success of in-vessel retention is not the mass of the molten light metal above the oxide pool but the heat generation rate

  14. On the System of Place Name Signs in Estonian Sign Language

    Directory of Open Access Journals (Sweden)

    Liina Paales

    2011-05-01

    Full Text Available A place name sign is a linguistic-cultural marker that includes both memory and landscape. The author regards toponymic signs in Estonian Sign Language as representations of images held by the Estonian Deaf community: they reflect the geographical place, the period, the relationships of the Deaf community with hearing community, and the common and distinguishing features of the two cultures perceived by community's members. Name signs represent an element of signlore, which includes various types of creative linguistic play. There are stories hidden behind the place name signs that reveal the etymological origin of place name signs and reflect the community's memory. The purpose of this article is twofold. Firstly, it aims to introduce Estonian place name signs as Deaf signlore forms, analyse their structure and specify the main formation methods. Secondly, it interprets place-denoting signs in the light of understanding the foundations of Estonian Sign Language, Estonian Deaf education and education history, the traditions of local Deaf communities, and also of the cultural and local traditions of the dominant hearing communities. Both perspectives - linguistic and folkloristic - are represented in the current article.

  15. [Morphological signs of mitochondrial cytopathy in skeletal muscles and micro-vessel walls in a patient with cerebral artery dissection associated with MELAS syndrome].

    Science.gov (United States)

    Sakharova, A V; Kalashnikova, L A; Chaĭkovskaia, R P; Mir-Kasimov, M F; Nazarova, M A; Pykhtina, T N; Dobrynina, L A; Patrusheva, N L; Patrushev, L I; Protskiĭ, S V

    2012-01-01

    Skin and muscles biopsy specimens of a patient harboring A3243G mutation in mitochondrial DNA, with dissection of internal carotid and vertebral arteries, associated with MELAS were studied using histochemical and electron-microscopy techniques. Ragged red fibers, regional variability of SDH histochemical reaction, two types of morphologically atypical mitochondria and their aggregation were found in muscle. There was correlation between SDH histochemical staining and number of mitochondria revealed by electron microscopy in muscle tissue. Similar mitochondrial abnormality, their distribution and cell lesions followed by extra-cellular matrix mineralization were found in the blood vessel walls. In line with generalization of cytopathy process caused by gene mutation it can be supposed that changes found in skin and muscle microvessels also exist in large cerebral vessels causing the vessel wall "weakness", predisposing them to dissection.

  16. Radiographic and tomographic aspects of meningeal hemangiosarcoma in a German Shepherd dog with clinical signs of cauda equina sindrome

    International Nuclear Information System (INIS)

    Pinto, A.C.B. de C.F.; Ferrigno, C.R.A.; Matera, J.M.; Torres, L.N.; Sinhorini, I.L.; Cortopassi, S.R.G.; Hage, M.C.F.N.S.

    2007-01-01

    Hemangiosarcoma is a highly malignant neoplasia derived from the endothelial cell line and, therefore, can arise in any tissue with blood vessels. A case of a rare meningeal site of hemangiosarcoma in an eight-year old German Shepherd dog with clinical signs of cauda equina sindrome is described. The diagnosis was made based on clinical, radiographic, tomographic and histopathological findings [pt

  17. Evaluation of carotid vessel wall enhancement with image subtraction after gadobenate dimeglumine-enhanced MR angiography

    International Nuclear Information System (INIS)

    Sardanelli, Francesco; Di Leo, Giovanni; Aliprandi, Alberto; Flor, Nicola; Papini, Giacomo D.E.; Roccatagliata, Luca; Cotticelli, Biagio; Nano, Giovanni; Cornalba, Gianpaolo

    2009-01-01

    Objectives: This study was aimed at testing the value of image subtraction for evaluating carotid vessel wall enhancement in contrast-enhanced MR angiography (MRA). Materials and methods: IRB approval was obtained. The scans of 81 consecutive patients who underwent carotid MRA with 0.1 mmol/kg of gadobenate dimeglumine were reviewed. Axial carotid 3D T1-weighted fast low-angle shot sequence before and 3 min after contrast injection were acquired and subtracted (enhanced minus unenhanced). Vessel wall enhancement was assigned a four-point score using native or subtracted images from 0 (no enhancement) to 3 (strong enhancement). Stenosis degree was graded according to NASCET. Results: With native images, vessel wall enhancement was detected in 20/81 patients (25%) and in 20/161 carotids (12%), and scored 2.0 ± 0.6 (mean ± standard deviation); with subtracted images, in 21/81 (26%) and 22/161 (14%), and scored 2.5 ± 0.6, respectively (P < 0.001, Sign test). The overall stenosis degree distribution was: mild, 41/161 (25%); moderate, 77/161 (48%); severe, 43/161 (27%). Carotids with moderate stenosis showed vessel wall enhancement with a frequency (17/77, 22%) significantly higher than that observed in carotids with mild stenosis (1/41, 2%) (P = 0.005, Fisher exact test) and higher, even though with borderline significance (P = 0.078, Fisher exact test), than that observed in carotids with severe stenosis (4/43, 9%). Conclusion: Roughly a quarter of patients undergoing carotid MRA showed vessel wall enhancement. Image subtraction improved vessel wall enhancement conspicuity. Vessel wall enhancement seems to be an event relatively independent from the degree of stenosis. Further studies are warranted to define the relation between vessel wall enhancement and histopathology, inflammatory status, and instability.

  18. Assembly of the sectors and ports of the ITER vacuum vessel

    International Nuclear Information System (INIS)

    Corino, S.; Moreno, R.

    2014-01-01

    The International Thermonuclear Experimental Reactor, ITER is a very complex Project that aims to prove the technical reliability of nuclear fusion. ITER has been Ensa's commitment to the future to strengthen as one of the main manufacturers of big equipment and services internationally in the nuclear field. Ensa started working on the qualification process to be able to bid for the 'Assembly of the ITER vacuum vessel' in June 2010, after two and a half years of pre-qualification, offers, clarifications and long technical meetings, that were followed by commercial meetings Ensa achieved its goal. The 30 of November, Ensa signed what at that time was the biggest of the supplies signed by IO (ITER Organization). A lot of efforts and hard work had been done in order to achieve this goal, but the hardest of all was yet to come, after the signature of the contract, Ensa has 7 years ahead to achieve the final goal, the assembly and welding of the 9 sectors that put together the ITER vacuum vessel and the 54 ports that will allow the assembly of the different auxiliary systems. The scope of the works to be performed can generally be divided into the following areas: - Welding of the sectors and ports; - Non-destructive tests; - Machining; - Dimensional Controls. In order to achieve this goal, the project has been divided into 3 different phases. - Development phase: January 2013 - July 2015; - Pre-production phase: July 2015 - February 2016; - Production phase: February 2016 - February 2020

  19. Cryopreserved embryo transfer: adjacent or non-adjacent to failed fresh long GnRH-agonist protocol IVF cycle.

    Science.gov (United States)

    Volodarsky-Perel, Alexander; Eldar-Geva, Talia; Holzer, Hananel E G; Schonberger, Oshrat; Reichman, Orna; Gal, Michael

    2017-03-01

    The optimal time to perform cryopreserved embryo transfer (CET) after a failed oocyte retrieval-embryo transfer (OR-ET) cycle is unknown. Similar clinical pregnancy rates were recently reported in immediate and delayed CET, performed after failed fresh OR-ET, in cycles with the gonadotrophin-releasing hormone (GnRH) antagonist protocol. This study compared outcomes of CET performed adjacently (<50 days, n = 67) and non-adjacently (≥50 to 120 days, n = 62) to the last OR-day of cycles with the GnRH agonist down-regulation protocol. Additional inclusion criteria were patients' age 20-38 years, the transfer of only 1-2 cryopreserved embryos, one treatment cycle per patient and artificial preparation for CET. Significantly higher implantation, clinical pregnancy and live birth rates were found in the non-adjacent group than in the adjacent group: 30.5% versus 11.3% (P = 0.001), 41.9% versus 17.9% (P = 0.003) and 32.3% versus 13.4% (P = 0.01), respectively. These results support the postponement of CET after a failed OR-ET for at least one menstrual cycle, when a preceding long GnRH-agonist protocol is used. Copyright © 2016 Reproductive Healthcare Ltd. Published by Elsevier Ltd. All rights reserved.

  20. Automated method for identification and artery-venous classification of vessel trees in retinal vessel networks.

    Science.gov (United States)

    Joshi, Vinayak S; Reinhardt, Joseph M; Garvin, Mona K; Abramoff, Michael D

    2014-01-01

    The separation of the retinal vessel network into distinct arterial and venous vessel trees is of high interest. We propose an automated method for identification and separation of retinal vessel trees in a retinal color image by converting a vessel segmentation image into a vessel segment map and identifying the individual vessel trees by graph search. Orientation, width, and intensity of each vessel segment are utilized to find the optimal graph of vessel segments. The separated vessel trees are labeled as primary vessel or branches. We utilize the separated vessel trees for arterial-venous (AV) classification, based on the color properties of the vessels in each tree graph. We applied our approach to a dataset of 50 fundus images from 50 subjects. The proposed method resulted in an accuracy of 91.44% correctly classified vessel pixels as either artery or vein. The accuracy of correctly classified major vessel segments was 96.42%.

  1. LSE-Sign: A lexical database for Spanish Sign Language.

    Science.gov (United States)

    Gutierrez-Sigut, Eva; Costello, Brendan; Baus, Cristina; Carreiras, Manuel

    2016-03-01

    The LSE-Sign database is a free online tool for selecting Spanish Sign Language stimulus materials to be used in experiments. It contains 2,400 individual signs taken from a recent standardized LSE dictionary, and a further 2,700 related nonsigns. Each entry is coded for a wide range of grammatical, phonological, and articulatory information, including handshape, location, movement, and non-manual elements. The database is accessible via a graphically based search facility which is highly flexible both in terms of the search options available and the way the results are displayed. LSE-Sign is available at the following website: http://www.bcbl.eu/databases/lse/.

  2. Sign language perception research for improving automatic sign language recognition

    NARCIS (Netherlands)

    Ten Holt, G.A.; Arendsen, J.; De Ridder, H.; Van Doorn, A.J.; Reinders, M.J.T.; Hendriks, E.A.

    2009-01-01

    Current automatic sign language recognition (ASLR) seldom uses perceptual knowledge about the recognition of sign language. Using such knowledge can improve ASLR because it can give an indication which elements or phases of a sign are important for its meaning. Also, the current generation of

  3. Morphological signs of the intravital contraction (retraction of thrombotic emboli

    Directory of Open Access Journals (Sweden)

    R R Khismatullin

    2018-02-01

    Full Text Available Aim. To establish whether contraction (retraction of thrombi and thrombotic emboli occurs in vivo using structural signs of blood clot compression, such as compressive deformation of erythrocytes and redistribution of fibrin on the surface of a clot. Methods. Three postmortem pulmonary thrombotic emboli were examined by scanning electron microscopy and light microscopy after staining with hematoxylin and eosin as well as with Mallory’s method. Results. In 2 studied pulmonary emboli, extracted 7 and 15 hours after patients’ death, polyhedral erythrocytes (polyhedrocytes were revealed that were formed as a result of mechanical deformation under the action of contractile forces generated by activated platelets. In addition, the uneven distribution of fibrin within the emboli was found with displacement of fibrin to the periphery of the emboli, which is characteristic for contracted blood clot. In the first and the «oldest» clot extracted 38 hours after the patient’s death, the described contraction signs were absent, which was likely related to the postmortem autolysis or intravital pathological impairment of contraction. Conclusion. Thrombotic emboli ex vivo have morphological signs of contraction, suggesting intravital compression of the primary thrombi and/or thrombotic emboli, which might be an important pathogenetic mechanism for modulation of impaired blood flow at the sites of thrombotic occlusion of a vessel; the presence or absence of compressed erythrocytes inside and predominant location of fibrin on the periphery of a thrombus or embolus can potentially serve as additional pathomorphological criteria of death coming prescription.

  4. Smarandachely Adjacent-Vertex-Distinguishing Proper Edge Chromatic Number of Cm∨Kn

    OpenAIRE

    Shunqin Liu

    2016-01-01

    According to different conditions, researchers have defined a great deal of coloring problems and the corresponding chromatic numbers. Such as, adjacent-vertex-distinguishing total chromatic number, adjacent-vertex-distinguishing proper edge chromatic number, smarandachely-adjacent-vertex-distinguishing proper edge chromatic number, smarandachely-adjacent-vertex-distinguishing proper total chromatic number. And we focus on the smarandachely adjacent-vertex-distinguishing proper edge chromatic...

  5. Pressure vessel for nuclear reactor plant consisting of several pre-stressed cast pressure vessels

    International Nuclear Information System (INIS)

    Bodmann, E.

    1984-01-01

    Several cylindrical pressure vessel components made of pressure castings are arranged on a sector of a circle around the cylindrical cast pressure vessel for accommodating the helium cooled HTR. Each component pressure vessel is connected to the reactor vessel by a horizontal gas duct. The contact surfaces between reactor and component pressure vessel are in one plane. In the spaces between the individual component pressure vessels, there are supporting blocks made of cast iron, which are hollow and also have flat surfaces. With the reactor vessel and the component pressure vessels they form a disc-shaped connecting part below and above the gas ducts. (orig./PW)

  6. Loading effects of anterior cervical spine fusion on adjacent segments

    Directory of Open Access Journals (Sweden)

    Chien-Shiung Wang

    2012-11-01

    Full Text Available Adjacent segment degeneration typically follows anterior cervical spine fusion. However, the primary cause of adjacent segment degeneration remains unknown. Therefore, in order to identify the loading effects that cause adjacent segment degeneration, this study examined the loading effects to superior segments adjacent to fused bone following anterior cervical spine fusion. The C3–C6 cervical spine segments of 12 sheep were examined. Specimens were divided into the following groups: intact spine (group 1; and C5–C6 segments that were fused via cage-instrumented plate fixation (group 2. Specimens were cycled between 20° flexion and 15° extension with a displacement control of 1°/second. The tested parameters included the range of motion (ROM of each segment, torque and strain on both the body and inferior articular process at the superior segments (C3–C4 adjacent to the fused bone, and the position of the neutral axis of stress at under 20° flexion and 15° extension. Under flexion and Group 2, torque, ROM, and strain on both the bodies and facets of superior segments adjacent to the fused bone were higher than those of Group 1. Under extension and Group 2, ROM for the fused segment was less than that of Group 1; torque, ROM, and stress on both the bodies and facets of superior segments adjacent to the fused bone were higher than those of Group 1. These analytical results indicate that the muscles and ligaments require greater force to achieve cervical motion than the intact spine following anterior cervical spine fusion. In addition, ROM and stress on the bodies and facets of the joint segments adjacent to the fused bone were significantly increased. Under flexion, the neutral axis of the stress on the adjacent segment moved backward, and the stress on the bodies of the segments adjacent to the fused bone increased. These comparative results indicate that increased stress on the adjacent segments is caused by stress-shielding effects

  7. Probabilistic retinal vessel segmentation

    Science.gov (United States)

    Wu, Chang-Hua; Agam, Gady

    2007-03-01

    Optic fundus assessment is widely used for diagnosing vascular and non-vascular pathology. Inspection of the retinal vasculature may reveal hypertension, diabetes, arteriosclerosis, cardiovascular disease and stroke. Due to various imaging conditions retinal images may be degraded. Consequently, the enhancement of such images and vessels in them is an important task with direct clinical applications. We propose a novel technique for vessel enhancement in retinal images that is capable of enhancing vessel junctions in addition to linear vessel segments. This is an extension of vessel filters we have previously developed for vessel enhancement in thoracic CT scans. The proposed approach is based on probabilistic models which can discern vessels and junctions. Evaluation shows the proposed filter is better than several known techniques and is comparable to the state of the art when evaluated on a standard dataset. A ridge-based vessel tracking process is applied on the enhanced image to demonstrate the effectiveness of the enhancement filter.

  8. ITER vacuum vessel design and electromagnetic analysis on in-vessel components

    International Nuclear Information System (INIS)

    Ioki, K.; Johnson, G.; Shimizu, K.; Williamson, D.; Iizuka, T.

    1995-01-01

    Major functional requirements for the vacuum vessel are to provide the first safety barrier and to support electromagnetic loads due to plasma disruptions and vertical displacement events, and to withstand plausible accidents without losing confinement. A double wall structure concept has been developed for the vacuum vessel due to its beneficial characteristics from the viewpoints of structural integrity and electrical continuity. An electromagnetic analysis of the blanket modules and the vacuum vessel has been performed to investigate force distributions on in-vessel components. According to the vertical displacement events (VDE) scenario, which assumes a critical q-value of 1.5, the total downward vertical force, induced by coupling between the eddy current and external fields, is about 110 MN. We have performed a stress analysis for the vacuum vessel using the VDE disruption forces acting on the blankets, and a maximum stress intensity of 112 MPa was obtained in the vicinity of the lower support of the vessel. (orig.)

  9. Research vessels

    Digital Repository Service at National Institute of Oceanography (India)

    Rao, P.S.

    The role of the research vessels as a tool for marine research and exploration is very important. Technical requirements of a suitable vessel and the laboratories needed on board are discussed. The history and the research work carried out...

  10. 'Felson Signs' revisited

    International Nuclear Information System (INIS)

    George, Phiji P.; Irodi, Aparna; Keshava, Shyamkumar N.; Lamont, Anthony C.

    2014-01-01

    In this article we revisit, with the help of images, those classic signs in chest radiography described by Dr Benjamin Felson himself, or other illustrious radiologists of his time, cited and discussed in 'Chest Roentgenology'. We briefly describe the causes of the signs, their utility and the differential diagnosis to be considered when each sign is seen. Wherever possible, we use CT images to illustrate the basis of some of these classic radiographic signs.

  11. Integration of ITER in-vessel diagnostic components in the vacuum vessel

    International Nuclear Information System (INIS)

    Encheva, A.; Bertalot, L.; Macklin, B.; Vayakis, G.; Walker, C.

    2009-01-01

    The integration of ITER in-vessel diagnostic components is an important engineering activity. The positioning of the diagnostic components must correlate not only with their functional specifications but also with the design of the major parts of ITER torus, in particular the vacuum vessel, blanket modules, blanket manifolds, divertor, and port plugs, some of which are not yet finally designed. Moreover, the recently introduced Edge Localised Mode (ELM)/Vertical Stability (VS) coils mounted on the vacuum vessel inner wall call for not only more than a simple review of the engineering design settled down for several years now, but also for a change in the in-vessel distribution of the diagnostic components and their full impact has yet to be determined. Meanwhile, the procurement arrangement (a document defining roles and responsibilities of ITER Organization and Domestic Agency(s) (DAs) for each in-kind procurement including technical scope of work, quality assurance requirements, schedule, administrative matters) for the vacuum vessel must be finalized. These make the interface process even more challenging in terms of meeting the vacuum vessel (VV) procurement arrangement's deadline. The process of planning the installation of all the ITER diagnostics and integrating their installation into the ITER Integrated Project Schedule (IPS) is now underway. This paper covers the progress made recently on updating and issuing the interfaces of the in-vessel diagnostic components with the vacuum vessel, outlines the requirements for their attachment and summarises the installation sequence.

  12. sign-by-sign'' correlation

    International Nuclear Information System (INIS)

    Schmidt, Sabine; Lepori, Domenico; Meuwly, Jean-Yves; Duvoisin, Bertrand; Meuli, Reto; Schnyder, Pierre; Denys, Alban; Michetti, Pierre; Felley, Christian; Melle, Guy van

    2003-01-01

    Our objective was a prospective comparison of MR enteroclysis (MRE) with multidetector spiral-CT enteroclysis (MSCTE). Fifty patients with various suspected small bowel diseases were investigated by MSCTE and MRE. The MSCTE was performed using slices of 2.5 mm, immediately followed by MRE, obtaining T1- and T2-weighted sequences, including gadolinium-enhanced acquisition with fat saturation. Three radiologists independently evaluated MSCTE and MRE searching for 12 pathological signs. Interobserver agreement was calculated. Sensitivities and specificities resulted from comparison with pathological results (n=29) and patient's clinical evolution (n=21). Most pathological signs, such as bowel wall thickening (BWT), bowel wall enhancement (BWE) and lymphadenopathy (ADP), showed better interobserver agreement on MSCTE than on MRE (BWT: 0.65 vs 0.48; BWE: 0.51 vs 0.37; ADP: 0.52 vs 0.15). Sensitivity of MSCTE was higher than that of MRE in detecting BWT (88.9 vs 60%), BWE (78.6 vs 55.5%) and ADP (63.8 vs 14.3%). Wilcoxon signed-rank test revealed significantly better sensitivity of MSCTE than that of MRE for each observer (p=0.028, p=0.046, p=0.028, respectively). Taking the given study design into account, MSCTE provides better sensitivity in detecting lesions of the small bowel than MRE, with higher interobserver agreement. (orig.)

  13. FFTF and CRBRP reactor vessels

    International Nuclear Information System (INIS)

    Morgan, R.E.

    1977-01-01

    The Fast Flux Test Facility (FFTF) reactor vessel and the Clinch River Breeder Reactor Plant (CRBRP) reactor vessel each serve to enclose a fast spectrum reactor core, contain the sodium coolant, and provide support and positioning for the closure head and internal structure. Each vessel is located in its reactor cavity and is protected by a guard vessel which would ensure continued decay heat removal capability should a major system leak develop. Although the two plants have significantly different thermal power ratings, 400 megawatts for FFTF and 975 megawatts for CRBRP, the two reactor vessels are comparable in size, the CRBRP vessel being approximately 28% longer than the FFTF vessel. The FFTF vessel diameter was controlled by the space required for the three individual In-Vessel Handling Machines and Instrument Trees. Utilization of the triple rotating plug scheme for CRBRP refueling enables packaging of the larger CRBRP core in a vessel the same diameter as the FFTF vessel

  14. Tumor Blood Vessel Dynamics

    Science.gov (United States)

    Munn, Lance

    2009-11-01

    ``Normalization'' of tumor blood vessels has shown promise to improve the efficacy of chemotherapeutics. In theory, anti-angiogenic drugs targeting endothelial VEGF signaling can improve vessel network structure and function, enhancing the transport of subsequent cytotoxic drugs to cancer cells. In practice, the effects are unpredictable, with varying levels of success. The predominant effects of anti-VEGF therapies are decreased vessel leakiness (hydraulic conductivity), decreased vessel diameters and pruning of the immature vessel network. It is thought that each of these can influence perfusion of the vessel network, inducing flow in regions that were previously sluggish or stagnant. Unfortunately, when anti-VEGF therapies affect vessel structure and function, the changes are dynamic and overlapping in time, and it has been difficult to identify a consistent and predictable normalization ``window'' during which perfusion and subsequent drug delivery is optimal. This is largely due to the non-linearity in the system, and the inability to distinguish the effects of decreased vessel leakiness from those due to network structural changes in clinical trials or animal studies. We have developed a mathematical model to calculate blood flow in complex tumor networks imaged by two-photon microscopy. The model incorporates the necessary and sufficient components for addressing the problem of normalization of tumor vasculature: i) lattice-Boltzmann calculations of the full flow field within the vasculature and within the tissue, ii) diffusion and convection of soluble species such as oxygen or drugs within vessels and the tissue domain, iii) distinct and spatially-resolved vessel hydraulic conductivities and permeabilities for each species, iv) erythrocyte particles advecting in the flow and delivering oxygen with real oxygen release kinetics, v) shear stress-mediated vascular remodeling. This model, guided by multi-parameter intravital imaging of tumor vessel structure

  15. Non parametric, self organizing, scalable modeling of spatiotemporal inputs: the sign language paradigm.

    Science.gov (United States)

    Caridakis, G; Karpouzis, K; Drosopoulos, A; Kollias, S

    2012-12-01

    Modeling and recognizing spatiotemporal, as opposed to static input, is a challenging task since it incorporates input dynamics as part of the problem. The vast majority of existing methods tackle the problem as an extension of the static counterpart, using dynamics, such as input derivatives, at feature level and adopting artificial intelligence and machine learning techniques originally designed for solving problems that do not specifically address the temporal aspect. The proposed approach deals with temporal and spatial aspects of the spatiotemporal domain in a discriminative as well as coupling manner. Self Organizing Maps (SOM) model the spatial aspect of the problem and Markov models its temporal counterpart. Incorporation of adjacency, both in training and classification, enhances the overall architecture with robustness and adaptability. The proposed scheme is validated both theoretically, through an error propagation study, and experimentally, on the recognition of individual signs, performed by different, native Greek Sign Language users. Results illustrate the architecture's superiority when compared to Hidden Markov Model techniques and variations both in terms of classification performance and computational cost. Copyright © 2012 Elsevier Ltd. All rights reserved.

  16. The TPX vacuum vessel and in-vessel components

    International Nuclear Information System (INIS)

    Heitzenroeder, P.; Bialek, J.; Ellis, R.; Kessel, C.; Liew, S.

    1994-01-01

    The Tokamak Physics Experiment (TPX) is a superconducting tokamak with double-null diverters. TPX is designed for 1,000-second discharges with the capability of being upgraded to steady state operation. High neutron yields resulting from the long duration discharges require that special consideration be given to materials and maintainability. A unique feature of the TPX is the use of a low activation, titanium alloy vacuum vessel. Double-wall vessel construction is used since it offers an efficient solution for shielding, bakeout and cooling. Contained within the vacuum vessel are the passive coil system, Plasma Facing Components (PFCs), magnetic diagnostics, and the internal control coils. All PFCs utilize carbon-carbon composites for exposed surfaces

  17. Specific Fluorescence in Situ Hybridization (FISH) Test to Highlight Colonization of Xylem Vessels by Xylella fastidiosa in Naturally Infected Olive Trees (Olea europaea L.)

    Science.gov (United States)

    Cardinale, Massimiliano; Luvisi, Andrea; Meyer, Joana B.; Sabella, Erika; De Bellis, Luigi; Cruz, Albert C.; Ampatzidis, Yiannis; Cherubini, Paolo

    2018-01-01

    The colonization behavior of the Xylella fastidiosa strain CoDiRO, the causal agent of olive quick decline syndrome (OQDS), within the xylem of Olea europaea L. is still quite controversial. As previous literature suggests, even if xylem vessel occlusions in naturally infected olive plants were observed, cell aggregation in the formation of occlusions had a minimal role. This observation left some open questions about the whole behavior of the CoDiRO strain and its actual role in OQDS pathogenesis. In order to evaluate the extent of bacterial infection in olive trees and the role of bacterial aggregates in vessel occlusions, we tested a specific fluorescence in situ hybridization (FISH) probe (KO 210) for X. fastidiosa and quantified the level of infection and vessel occlusion in both petioles and branches of naturally infected and non-infected olive trees. All symptomatic petioles showed colonization by X. fastidiosa, especially in the larger innermost vessels. In several cases, the vessels appeared completely occluded by a biofilm containing bacterial cells and extracellular matrix and the frequent colonization of adjacent vessels suggested a horizontal movement of the bacteria. Infected symptomatic trees had 21.6 ± 10.7% of petiole vessels colonized by the pathogen, indicating an irregular distribution in olive tree xylem. Thus, our observations point out the primary role of the pathogen in olive vessel occlusions. Furthermore, our findings indicate that the KO 210 FISH probe is suitable for the specific detection of X. fastidiosa. PMID:29681910

  18. Hygrometric measurement for on-line monitoring of PWR vessel head penetrations

    International Nuclear Information System (INIS)

    Germain, J.L.; Loisy, F.; Apolzan, S.

    1994-06-01

    In September 1991, a small leak was found on one of the reactor's upper vessel head penetrations. After inspection, other non-throughwall cracks were localized in the lower part of the vessel head adapter in questions. The same type of crack was later found inside some adapters on other French PWR units. After repairs, the safety authorities granted approval to continue unit operation, with the specific provision that a system for ongoing monitoring of the penetrations be set up. Two types of system were selected to detect leaks through any potential cracks: the first is based on nitrogen-13 detection and the second on steam detection. Both systems call for sampling the air in a confined space above the vessel head. The number and distribution of sampling taps in the circuit, and the balancing of their respective flow rates, are factors in proper monitoring of all vessel head penetrations. Gas-injection holes are also installed in the confined space. These holes are used during the sampling system qualification tests to simulate leaks in various positions and calculate the effective performance of the sampling system. Leaks are simulated using a helium-base gas tracer and measuring tracer concentrations in the sampling system. The system for measuring steam levels in air samples uses chilled-mirror hygrometers. A microcomputer takes regular readings, drives the various automatic functions of the measurement system and automatically analyses the readings so as to monitor operations and trigger an alarm at the first sign of a leak. This system has now been installed for a year and a half on three French PWR units and is functioning satisfactorily. (authors). 5 figs

  19. Careful treatment planning enables safe ablation of liver tumors adjacent to major blood vessels by percutaneous irreversible electroporation (IRE).

    Science.gov (United States)

    Kos, Bor; Voigt, Peter; Miklavcic, Damijan; Moche, Michael

    2015-09-01

    Irreversible electroporation (IRE) is a tissue ablation method, which relies on the phenomenon of electroporation. When cells are exposed to a sufficiently electric field, the plasma membrane is disrupted and cells undergo an apoptotic or necrotic cell death. Although heating effects are known IRE is considered as non-thermal ablation technique and is currently applied to treat tumors in locations where thermal ablation techniques are contraindicated. The manufacturer of the only commercially available pulse generator for IRE recommends a voltage-to-distance ratio of 1500 to 1700 V/cm for treating tumors in the liver. However, major blood vessels can influence the electric field distribution. We present a method for treatment planning of IRE which takes the influence of blood vessels on the electric field into account; this is illustrated on a treatment of 48-year-old patient with a metastasis near the remaining hepatic vein after a right side hemi-hepatectomy. Output of the numerical treatment planning method shows that a 19.9 cm3 irreversible electroporation lesion was generated and the whole tumor was covered with at least 900 V/cm. This compares well with the volume of the hypodense lesion seen in contrast enhanced CT images taken after the IRE treatment. A significant temperature raise occurs near the electrodes. However, the hepatic vein remains open after the treatment without evidence of tumor recurrence after 6 months. Treatment planning using accurate computer models was recognized as important for electrochemotherapy and irreversible electroporation. An important finding of this study was, that the surface of the electrodes heat up significantly. Therefore the clinical user should generally avoid placing the electrodes less than 4 mm away from risk structures when following recommendations of the manufacturer.

  20. An experimental study on feasibility of ex-vessel cooling through the external guide vessel

    International Nuclear Information System (INIS)

    Kang, Kyoung-Ho; Kim, Jong-Hwan; Park, Rae-Jun; Kim, Sang-Baik

    2000-01-01

    This paper presents the results of a series of experiments for assessing the efficacy of ex-vessel cooling through the external guide vessel during a severe accident. Four tests were performed in the LAVA test facility at KAERI, varying the boundary conditions at the outer surface of the vessel. The first test was a dry condition test conducted without cooling the outside of the vessel. On the other hand, in the second test, the cooling of the vessel surface was produced by gravity-driven forced injection of water along the annular gap of 25 mm between the vessel and the external guide vessel. Water flow rate was about 0.85 kg/s and total mass of available water was 300 kg. For the evaluation of the water flow rate effect, the third test was performed with a pool type cooling in the annulus without any circulation of water. These two external cooling tests were performed under elevated pressure of about 1.6 MPa. Finally, the fourth test was conducted under atmospheric pressure to evaluate the effect of system pressure on boiling heat transfer characteristics. In the dry test and the pool type ex-vessel cooling test performed under atmospheric pressure, the vessel was failed by a melt penetration at about 40 degree upper position from the vessel bottom, which is coincident with the boundary of the Al 2 O 3 /Fe melt separated layers. On the other hand, in both of the ex-vessel cooling tests conducted under elevated pressure of about 1.6 MPa, the vessel didn't fail. Compared with the pool boiling test, the vessel experienced effective cooling due to the inlet flow in the forced flow test. Synthesized the results of the tests, it was shown that the heat removal with ex-vessel cooling through the guide vessel is feasible, but the additional evaluations should be performed to guarantee enough thermal margin. (author)

  1. Special enclosure for a pressure vessel

    International Nuclear Information System (INIS)

    Wedellsborg, B.W.; Wedellsborg, U.W.

    1993-01-01

    A pressure vessel enclosure is described comprising a primary pressure vessel, a first pressure vessel containment assembly adapted to enclose said primary pressure vessel and be spaced apart therefrom, a first upper pressure vessel jacket adapted to enclose the upper half of said first pressure vessel containment assembly and be spaced apart therefrom, said upper pressure vessel jacket having an upper rim and a lower rim, each of said rims connected in a slidable relationship to the outer surface of said first pressure vessel containment assembly, mean for connecting in a sealable relationship said upper rim of said first upper pressure vessel jacket to the outer surface of said first pressure vessel containment assembly, means for connecting in a sealable relationship said lower rim of said first upper pressure vessel jacket to the outer surface of said first pressure vessel containment assembly, a first lower pressure vessel jacket adapted to enclose the lower half of said first pressure vessel containment assembly and be spaced apart therefrom, said lower pressure vessel jacket having an upper rim connected in a slidable relationship to the outer surface of said first pressure vessel containment assembly, and means for connecting in a sealable relationship said upper rim of said first lower pressure vessel jacket to the outer surface of said first pressure vessel containment assembly, a second upper pressure vessel jacket adapted to enclose said first upper pressure vessel jacket and be spaced apart therefrom, said second upper pressure vessel jacket having an upper rim and a lower rim, each of said rims adapted to slidably engage the outer surface of said first upper pressure vessel jacket, means for sealing said rims, a second lower pressure vessel jacket adapted to enclose said first lower pressure vessel jacket and be spaced apart therefrom

  2. Vessel classification method based on vessel behavior in the port of Rotterdam

    NARCIS (Netherlands)

    Zhou, Y.; Daamen, W.; Vellinga, T.; Hoogendoorn, S.P.

    2015-01-01

    AIS (Automatic Identification System) data have proven to be a valuable source to investigate vessel behavior. The analysis of AIS data provides a possibility to recognize vessel behavior patterns in a waterway area. Furthermore, AIS data can be used to classify vessel behavior into several

  3. Vessel Operating Units (Vessels)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains data for vessels that are greater than five net tons and have a current US Coast Guard documentation number. Beginning in1979, the NMFS...

  4. Sign Inference for Dynamic Signed Networks via Dictionary Learning

    Directory of Open Access Journals (Sweden)

    Yi Cen

    2013-01-01

    Full Text Available Mobile online social network (mOSN is a burgeoning research area. However, most existing works referring to mOSNs deal with static network structures and simply encode whether relationships among entities exist or not. In contrast, relationships in signed mOSNs can be positive or negative and may be changed with time and locations. Applying certain global characteristics of social balance, in this paper, we aim to infer the unknown relationships in dynamic signed mOSNs and formulate this sign inference problem as a low-rank matrix estimation problem. Specifically, motivated by the Singular Value Thresholding (SVT algorithm, a compact dictionary is selected from the observed dataset. Based on this compact dictionary, the relationships in the dynamic signed mOSNs are estimated via solving the formulated problem. Furthermore, the estimation accuracy is improved by employing a dictionary self-updating mechanism.

  5. Awareness of Deaf Sign Language and Gang Signs.

    Science.gov (United States)

    Smith, Cynthia; Morgan, Robert L.

    There have been increasing incidents of innocent people who use American Sign Language (ASL) or another form of sign language being victimized by gang violence due to misinterpretation of ASL hand formations. ASL is familiar to learners with a variety of disabilities, particularly those in the deaf community. The problem is that gang members have…

  6. Improvement to reactor vessel

    International Nuclear Information System (INIS)

    1974-01-01

    The vessel described includes a prestressed concrete vessel containing a chamber and a removable cover closing this chamber. The cover is in concrete and is kept in its closed position by main and auxiliary retainers, comprising fittings integral with the concrete of the vessel. The auxiliary retainers pass through the concrete of the cover. This improvement may be applied to BWR, PWR and LMFBR type reactor vessel [fr

  7. Integrating Multiple Autonomous Underwater Vessels, Surface Vessels and Aircraft into Oceanographic Research Vessel Operations

    Science.gov (United States)

    McGillivary, P. A.; Borges de Sousa, J.; Martins, R.; Rajan, K.

    2012-12-01

    Autonomous platforms are increasingly used as components of Integrated Ocean Observing Systems and oceanographic research cruises. Systems deployed can include gliders or propeller-driven autonomous underwater vessels (AUVs), autonomous surface vessels (ASVs), and unmanned aircraft systems (UAS). Prior field campaigns have demonstrated successful communication, sensor data fusion and visualization for studies using gliders and AUVs. However, additional requirements exist for incorporating ASVs and UASs into ship operations. For these systems to be optimally integrated into research vessel data management and operational planning systems involves addressing three key issues: real-time field data availability, platform coordination, and data archiving for later analysis. A fleet of AUVs, ASVs and UAS deployed from a research vessel is best operated as a system integrated with the ship, provided communications among them can be sustained. For this purpose, Disruptive Tolerant Networking (DTN) software protocols for operation in communication-challenged environments help ensure reliable high-bandwidth communications. Additionally, system components need to have considerable onboard autonomy, namely adaptive sampling capabilities using their own onboard sensor data stream analysis. We discuss Oceanographic Decision Support System (ODSS) software currently used for situational awareness and planning onshore, and in the near future event detection and response will be coordinated among multiple vehicles. Results from recent field studies from oceanographic research vessels using AUVs, ASVs and UAS, including the Rapid Environmental Picture (REP-12) cruise, are presented describing methods and results for use of multi-vehicle communication and deliberative control networks, adaptive sampling with single and multiple platforms, issues relating to data management and archiving, and finally challenges that remain in addressing these technological issues. Significantly, the

  8. In-vessel tritium

    International Nuclear Information System (INIS)

    Ueda, Yoshio; Ohya, Kaoru; Ashikawa, Naoko; Ito, Atsushi M.; Kato, Daiji; Kawamura, Gakushi; Takayama, Arimichi; Tomita, Yukihiro; Nakamura, Hiroaki; Ono, Tadayoshi; Kawashima, Hisato; Shimizu, Katsuhiro; Takizuka, Tomonori; Nakano, Tomohide; Nakamura, Makoto; Hoshino, Kazuo; Kenmotsu, Takahiro; Wada, Motoi; Saito, Seiki; Takagi, Ikuji; Tanaka, Yasunori; Tanabe, Tetsuo; Yoshida, Masafumi; Toma, Mitsunori; Hatayama, Akiyoshi; Homma, Yuki; Tolstikhina, Inga Yu.

    2012-01-01

    The in-vessel tritium research is closely related to the plasma-materials interaction. It deals with the edge-plasma-wall interaction, the wall erosion, transport and re-deposition of neutral particles and the effect of neutral particles on the fuel recycling. Since the in-vessel tritium shows a complex nonlinear behavior, there remain many unsolved problems. So far, behaviors of in-vessel tritium have been investigated by two groups A01 and A02. The A01 group performed experiments on accumulation and recovery of tritium in thermonuclear fusion reactors and the A02 group studied theory and simulation on the in-vessel tritium behavior. In the present article, outcomes of the research are reviewed. (author)

  9. Automatic sign language recognition inspired by human sign perception

    NARCIS (Netherlands)

    Ten Holt, G.A.

    2010-01-01

    Automatic sign language recognition is a relatively new field of research (since ca. 1990). Its objectives are to automatically analyze sign language utterances. There are several issues within the research area that merit investigation: how to capture the utterances (cameras, magnetic sensors,

  10. Inuit Sign Language: a contribution to sign language typology

    NARCIS (Netherlands)

    Schuit, J.; Baker, A.; Pfau, R.

    2011-01-01

    Sign language typology is a fairly new research field and typological classifications have yet to be established. For spoken languages, these classifications are generally based on typological parameters; it would thus be desirable to establish these for sign languages. In this paper, different

  11. Implicit vessel surface reconstruction for visualization and CFD simulation

    International Nuclear Information System (INIS)

    Schumann, Christian; Peitgen, Heinz-Otto; Neugebauer, Mathias; Bade, Ragnar; Preim, Bernhard

    2008-01-01

    Accurate and high-quality reconstructions of vascular structures are essential for vascular disease diagnosis and blood flow simulations.These applications necessitate a trade-off between accuracy and smoothness. An additional requirement for the volume grid generation for Computational Fluid Dynamics (CFD) simulations is a high triangle quality. We propose a method that produces an accurate reconstruction of the vessel surface with satisfactory surface quality. A point cloud representing the vascular boundary is generated based on a segmentation result. Thin vessels are subsampled to enable an accurate reconstruction. A signed distance field is generated using Multi-level Partition of Unity Implicits and subsequently polygonized using a surface tracking approach. To guarantee a high triangle quality, the surface is remeshed. Compared to other methods, our approach represents a good trade-off between accuracy and smoothness. For the tested data, the average surface deviation to the segmentation results is 0.19 voxel diagonals and the maximum equi-angle skewness values are below 0.75. The generated surfaces are considerably more accurate than those obtained using model-based approaches. Compared to other model-free approaches, the proposed method produces smoother results and thus better supports the perception and interpretation of the vascular topology. Moreover, the triangle quality of the generated surfaces is suitable for CFD simulations. (orig.)

  12. Transarterial chemoembolization through collateral vessels in hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ji Hye; Han, Joon Koo; Chung, Jin Wook; Park, Jae Hyung; Han, Man Chung [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1993-11-15

    We performed 70 procedures of transarterial chemoembolization (TAE) through extrahepatic collateral vessels (n=27) or parasitic feeders (n=18) in 45 hepatocellular carcinoma patients. The collaterals developed after interruption of the hepatic artery due to repeated TAE (n=17), surgical ligation (n=7)and primary celiac occlusion (n=3). Radiologic findings suggest the existence of parasitic or collateral supply for hepatocellular carcinoma were 1) a focal defect of Lipiodol retention on CT or plain film after TAE via the hepatic artery, 2) dilated and tortuous vessels around the mass on angiography, 3) persistent elevation of the level of serum alpha-fetoprotein or continuous clinical symptoms in spite of sufficient devascularization of the tumor via the hepatic artery, and 4) radiological findings of direct invasion into adjacent organ. The sites of the catheter placement were the inferior phrenic artery(n=19), omental branches(n=16), periportal collaterals (n=6), pancreaticodenal arcade (n=3), gastroduodenal artery(n=3), internal mammary artery (n=2), intercosal artery (n=2), lateral thoracic artery (n=1), bronchial artery (n=1), and colic branches (n=1). Masses feeded by the inferior phrenic and chest wall collaterals were usually located at the dome area of the liver, and the omental and gastroduodenal collaterals developed in the masses located at the inferior tip of the liver. After TAE via collateral vessels, 37 patients underwent follow-up study. In 18 cases(48%), the tumor favorably responded to TAE. Specific complications of collateral TAE were epigastric soreness (n=10), severe shoulder pain (n=4), and embolization of the spinal artery during embolization through the intercostal artery (n=1). In conclusion, various extrahepatic collateals are important alternative or addition routes for effective chemoembolization in patients with advanced hepatoma, and early recognition of the parasitic supply and the effort to perform TAE via collaterals is very

  13. Transarterial chemoembolization through collateral vessels in hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Kim, Ji Hye; Han, Joon Koo; Chung, Jin Wook; Park, Jae Hyung; Han, Man Chung

    1993-01-01

    We performed 70 procedures of transarterial chemoembolization (TAE) through extrahepatic collateral vessels (n=27) or parasitic feeders (n=18) in 45 hepatocellular carcinoma patients. The collaterals developed after interruption of the hepatic artery due to repeated TAE (n=17), surgical ligation (n=7)and primary celiac occlusion (n=3). Radiologic findings suggest the existence of parasitic or collateral supply for hepatocellular carcinoma were 1) a focal defect of Lipiodol retention on CT or plain film after TAE via the hepatic artery, 2) dilated and tortuous vessels around the mass on angiography, 3) persistent elevation of the level of serum alpha-fetoprotein or continuous clinical symptoms in spite of sufficient devascularization of the tumor via the hepatic artery, and 4) radiological findings of direct invasion into adjacent organ. The sites of the catheter placement were the inferior phrenic artery(n=19), omental branches(n=16), periportal collaterals (n=6), pancreaticodenal arcade (n=3), gastroduodenal artery(n=3), internal mammary artery (n=2), intercosal artery (n=2), lateral thoracic artery (n=1), bronchial artery (n=1), and colic branches (n=1). Masses feeded by the inferior phrenic and chest wall collaterals were usually located at the dome area of the liver, and the omental and gastroduodenal collaterals developed in the masses located at the inferior tip of the liver. After TAE via collateral vessels, 37 patients underwent follow-up study. In 18 cases(48%), the tumor favorably responded to TAE. Specific complications of collateral TAE were epigastric soreness (n=10), severe shoulder pain (n=4), and embolization of the spinal artery during embolization through the intercostal artery (n=1). In conclusion, various extrahepatic collateals are important alternative or addition routes for effective chemoembolization in patients with advanced hepatoma, and early recognition of the parasitic supply and the effort to perform TAE via collaterals is very

  14. Toward the Ideal Signing Avatar

    Directory of Open Access Journals (Sweden)

    Nicoletta Adamo-Villani

    2016-06-01

    Full Text Available The paper discusses ongoing research on the effects of a signing avatar's modeling/rendering features on the perception of sign language animation. It reports a recent study that aimed to determine whether a character's visual style has an effect on how signing animated characters are perceived by viewers. The stimuli of the study were two polygonal characters presenting two different visual styles: stylized and realistic. Each character signed four sentences. Forty-seven participants with experience in American Sign Language (ASL viewed the animated signing clips in random order via web survey. They (1 identified the signed sentences (if recognizable, (2 rated their legibility, and (3 rated the appeal of the signing avatar. Findings show that while character's visual style does not have an effect on subjects' perceived legibility of the signs and sign recognition, it has an effect on subjects' interest in the character. The stylized signing avatar was perceived as more appealing than the realistic one.

  15. Significance of satellite sign and spot sign in predicting hematoma expansion in spontaneous intracerebral hemorrhage.

    Science.gov (United States)

    Yu, Zhiyuan; Zheng, Jun; Ali, Hasan; Guo, Rui; Li, Mou; Wang, Xiaoze; Ma, Lu; Li, Hao; You, Chao

    2017-11-01

    Hematoma expansion is related to poor outcome in spontaneous intracerebral hemorrhage (ICH). Recently, a non-enhanced computed tomography (CT) based finding, termed the 'satellite sign', was reported to be a novel predictor for poor outcome in spontaneous ICH. However, it is still unclear whether the presence of the satellite sign is related to hematoma expansion. Initial computed tomography angiography (CTA) was conducted within 6h after ictus. Satellite sign on non-enhanced CT and spot sign on CTA were detected by two independent reviewers. The sensitivity and specificity of both satellite sign and spot sign were calculated. Receiver-operator analysis was conducted to evaluate their predictive accuracy for hematoma expansion. This study included 153 patients. Satellite sign was detected in 58 (37.91%) patients and spot sign was detected in 38 (24.84%) patients. Among 37 patients with hematoma expansion, 22 (59.46%) had satellite sign and 23 (62.16%) had spot sign. The sensitivity and specificity of satellite sign for prediction of hematoma expansion were 59.46% and 68.97%, respectively. The sensitivity and specificity of spot sign were 62.16% and 87.07%, respectively. The area under the curve (AUC) of satellite sign was 0.642 and the AUC of spot sign was 0.746. (P=0.157) CONCLUSION: Our results suggest that the satellite sign is an independent predictor for hematoma expansion in spontaneous ICH. Although spot sign has the higher predictive accuracy, satellite sign is still an acceptable predictor for hematoma expansion when CTA is unavailable. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Computational triadic algebras of signs

    Energy Technology Data Exchange (ETDEWEB)

    Zadrozny, W. [T.J. Watson Research Center, Yorktown Heights, NY (United States)

    1996-12-31

    We present a finite model of Peirce`s ten classes of signs. We briefly describe Peirce`s taxonomy of signs; we prove that any finite collection of signs can be extended to a finite algebra of signs in which all interpretants are themselves being interpreted; and we argue that Peirce`s ten classes of signs can be defined using constraints on algebras of signs. The paper opens the possibility of defining multimodal cognitive agents using Peirce`s classes of signs, and is a first step towards building a computational logic of signs based on Peirce`s taxonomies.

  17. NCSX Vacuum Vessel Fabrication

    International Nuclear Information System (INIS)

    Viola ME; Brown T; Heitzenroeder P; Malinowski F; Reiersen W; Sutton L; Goranson P; Nelson B; Cole M; Manuel M; McCorkle D.

    2005-01-01

    The National Compact Stellarator Experiment (NCSX) is being constructed at the Princeton Plasma Physics Laboratory (PPPL) in conjunction with the Oak Ridge National Laboratory (ORNL). The goal of this experiment is to develop a device which has the steady state properties of a traditional stellarator along with the high performance characteristics of a tokamak. A key element of this device is its highly shaped Inconel 625 vacuum vessel. This paper describes the manufacturing of the vessel. The vessel is being fabricated by Major Tool and Machine, Inc. (MTM) in three identical 120 o vessel segments, corresponding to the three NCSX field periods, in order to accommodate assembly of the device. The port extensions are welded on, leak checked, cut off within 1-inch of the vessel surface at MTM and then reattached at PPPL, to accommodate assembly of the close-fitting modular coils that surround the vessel. The 120 o vessel segments are formed by welding two 60 o segments together. Each 60 o segment is fabricated by welding ten press-formed panels together over a collapsible welding fixture which is needed to precisely position the panels. The vessel is joined at assembly by welding via custom machined 8-inch (20.3 cm) wide spacer ''spool pieces''. The vessel must have a total leak rate less than 5 X 10 -6 t-l/s, magnetic permeability less than 1.02(micro), and its contours must be within 0.188-inch (4.76 mm). It is scheduled for completion in January 2006

  18. Simulation of In-Vessel Corium Retention through External Reactor Vessel Cooling for SMART using SIMPLE

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Jin-Sung; Son, Donggun; Park, Rae-Joon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    Thermal load analysis from the corium pool to the outer reactor vessel in the lower plenum of the reactor vessel is necessary to evaluate the effect of the IVR-ERVC during a severe accident for SMART. A computational code called SIMPLE (Sever Invessel Melt Progression in Lower plenum Environment) has been developed for analyze transient behavior of molten corium in the lower plenum, interaction between corium and coolant, and heat-up and ablation of reactor vessel wall. In this study, heat load analysis of the reactor vessel for SMART has been conducted using the SIMPLE. Transient behavior of the molten corium in the lower plenum and IVR-ERVC for SMART has been simulated using SIMPLE. Heat flux from the corium pool to the outer reactor vessel is concentrated in metallic layer by the focusing effect. As a result, metallic layer shows higher temperature than the oxidic layer. Also, vessel wall of metallic layer has been ablated by the high in-vessel temperature. Ex-vessel temperature of the metallic layer was maintained 390 K and vessel thickness was maintained 14 cm. It means that the reactor vessel integrity is maintained by the IVR-ERVC.

  19. A computational algorithm addressing how vessel length might depend on vessel diameter

    Science.gov (United States)

    Jing Cai; Shuoxin Zhang; Melvin T. Tyree

    2010-01-01

    The objective of this method paper was to examine a computational algorithm that may reveal how vessel length might depend on vessel diameter within any given stem or species. The computational method requires the assumption that vessels remain approximately constant in diameter over their entire length. When this method is applied to three species or hybrids in the...

  20. A systematic review of definitions and classification systems of adjacent segment pathology.

    Science.gov (United States)

    Kraemer, Paul; Fehlings, Michael G; Hashimoto, Robin; Lee, Michael J; Anderson, Paul A; Chapman, Jens R; Raich, Annie; Norvell, Daniel C

    2012-10-15

    Systematic review. To undertake a systematic review to determine how "adjacent segment degeneration," "adjacent segment disease," or clinical pathological processes that serve as surrogates for adjacent segment pathology are classified and defined in the peer-reviewed literature. Adjacent segment degeneration and adjacent segment disease are terms referring to degenerative changes known to occur after reconstructive spine surgery, most commonly at an immediately adjacent functional spinal unit. These can include disc degeneration, instability, spinal stenosis, facet degeneration, and deformity. The true incidence and clinical impact of degenerative changes at the adjacent segment is unclear because there is lack of a universally accepted classification system that rigorously addresses clinical and radiological issues. A systematic review of the English language literature was undertaken and articles were classified using the Grades of Recommendation Assessment, Development, and Evaluation criteria. RESULTS.: Seven classification systems of spinal degeneration, including degeneration at the adjacent segment, were identified. None have been evaluated for reliability or validity specific to patients with degeneration at the adjacent segment. The ways in which terms related to adjacent segment "degeneration" or "disease" are defined in the peer-reviewed literature are highly variable. On the basis of the systematic review presented in this article, no formal classification system for either cervical or thoracolumbar adjacent segment disorders currently exists. No recommendations regarding the use of current classification of degeneration at any segments can be made based on the available literature. A new comprehensive definition for adjacent segment pathology (ASP, the now preferred terminology) has been proposed in this Focus Issue, which reflects the diverse pathology observed at functional spinal units adjacent to previous spinal reconstruction and balances

  1. Gesture, sign, and language: The coming of age of sign language and gesture studies.

    Science.gov (United States)

    Goldin-Meadow, Susan; Brentari, Diane

    2017-01-01

    How does sign language compare with gesture, on the one hand, and spoken language on the other? Sign was once viewed as nothing more than a system of pictorial gestures without linguistic structure. More recently, researchers have argued that sign is no different from spoken language, with all of the same linguistic structures. The pendulum is currently swinging back toward the view that sign is gestural, or at least has gestural components. The goal of this review is to elucidate the relationships among sign language, gesture, and spoken language. We do so by taking a close look not only at how sign has been studied over the past 50 years, but also at how the spontaneous gestures that accompany speech have been studied. We conclude that signers gesture just as speakers do. Both produce imagistic gestures along with more categorical signs or words. Because at present it is difficult to tell where sign stops and gesture begins, we suggest that sign should not be compared with speech alone but should be compared with speech-plus-gesture. Although it might be easier (and, in some cases, preferable) to blur the distinction between sign and gesture, we argue that distinguishing between sign (or speech) and gesture is essential to predict certain types of learning and allows us to understand the conditions under which gesture takes on properties of sign, and speech takes on properties of gesture. We end by calling for new technology that may help us better calibrate the borders between sign and gesture.

  2. Pressure vessel design manual

    CERN Document Server

    Moss, Dennis R

    2013-01-01

    Pressure vessels are closed containers designed to hold gases or liquids at a pressure substantially different from the ambient pressure. They have a variety of applications in industry, including in oil refineries, nuclear reactors, vehicle airbrake reservoirs, and more. The pressure differential with such vessels is dangerous, and due to the risk of accident and fatality around their use, the design, manufacture, operation and inspection of pressure vessels is regulated by engineering authorities and guided by legal codes and standards. Pressure Vessel Design Manual is a solutions-focused guide to the many problems and technical challenges involved in the design of pressure vessels to match stringent standards and codes. It brings together otherwise scattered information and explanations into one easy-to-use resource to minimize research and take readers from problem to solution in the most direct manner possible. * Covers almost all problems that a working pressure vessel designer can expect to face, with ...

  3. LANL Robotic Vessel Scanning

    Energy Technology Data Exchange (ETDEWEB)

    Webber, Nels W. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-11-25

    Los Alamos National Laboratory in J-1 DARHT Operations Group uses 6ft spherical vessels to contain hazardous materials produced in a hydrodynamic experiment. These contaminated vessels must be analyzed by means of a worker entering the vessel to locate, measure, and document every penetration mark on the vessel. If the worker can be replaced by a highly automated robotic system with a high precision scanner, it will eliminate the risks to the worker and provide management with an accurate 3D model of the vessel presenting the existing damage with the flexibility to manipulate the model for better and more in-depth assessment.The project was successful in meeting the primary goal of installing an automated system which scanned a 6ft vessel with an elapsed time of 45 minutes. This robotic system reduces the total time for the original scope of work by 75 minutes and results in excellent data accumulation and transmission to the 3D model imaging program.

  4. Signed Language Working Memory Capacity of Signed Language Interpreters and Deaf Signers

    Science.gov (United States)

    Wang, Jihong; Napier, Jemina

    2013-01-01

    This study investigated the effects of hearing status and age of signed language acquisition on signed language working memory capacity. Professional Auslan (Australian sign language)/English interpreters (hearing native signers and hearing nonnative signers) and deaf Auslan signers (deaf native signers and deaf nonnative signers) completed an…

  5. Information structure in Russian Sign Language and Sign Language of the Netherlands

    NARCIS (Netherlands)

    Kimmelman, V.

    2014-01-01

    This dissertation explores Information Structure in two sign languages: Sign Language of the Netherlands and Russian Sign Language. Based on corpus data and elicitation tasks we show how topic and focus are expressed in these languages. In particular, we show that topics can be marked syntactically

  6. Warning Signs of Bullying

    Science.gov (United States)

    ... of Aggressive Behavior Print Share Warning Signs for Bullying There are many warning signs that may indicate ... Get help right away . Signs a Child is Bullying Others Kids may be bullying others if they: ...

  7. PDX vacuum vessel stress analysis

    International Nuclear Information System (INIS)

    Nikodem, Z.D.

    1975-01-01

    A stress analysis of PDX vacuum vessel is described and the summary of results is presented. The vacuum vessel is treated as a toroidal shell of revolution subjected to an internal vacuum. The critical buckling pressure is calculated. The effects of the geometrical discontinuity at the juncture of toroidal shell head and cylindrical outside wall, and the concavity of the cylindrical wall are examined. An effect of the poloidal field coil supports and the vessel outside supports on the stress distribution in the vacuum vessel is determined. A method evaluating the influence of circular ports in the vessel wall on the stress level in the vessel is outlined

  8. The Danish Sign Language Dictionary

    DEFF Research Database (Denmark)

    Kristoffersen, Jette Hedegaard; Troelsgård, Thomas

    2010-01-01

    The entries of the The Danish Sign Language Dictionary have four sections:  Entry header: In this section the sign headword is shown as a photo and a gloss. The first occurring location and handshape of the sign are shown as icons.  Video window: By default the base form of the sign headword...... forms of the sign (only for classifier entries). In addition to this, frequent co-occurrences with the sign are shown in this section. The signs in the The Danish Sign Language Dictionary can be looked up through:  Handshape: Particular handshapes for the active and the passive hand can be specified...... to find signs that are not themselves lemmas in the dictionary, but appear in example sentences.  Topic: Topics can be chosen as search criteria from a list of 70 topics....

  9. Integrated conjugate heat transfer analysis method for in-vessel retention with external reactor vessel cooling - 15477

    International Nuclear Information System (INIS)

    Park, J.W.; Bae, J.H.; Seol, W.C.

    2015-01-01

    An integrated conjugate heat transfer analysis method for the thermal integrity of a reactor vessel under external reactor vessel cooling conditions is developed to resolve light metal layer focusing effect issue. The method calculates steady-state 3-dimensional temperature distribution of a reactor vessel using coupled conjugate heat transfer between in-vessel 3-layered stratified corium (metallic pool, oxide pool and heavy metal) and polar-angle dependent boiling heat transfer at the outer surface of a reactor vessel. The 3-layer corium heat transfer model is utilizing lumped-parameter thermal-resistance circuit method and ex-vessel boiling regimes are parametrically considered. The thermal integrity of a reactor vessel is addressed in terms of un-molten thickness profile. The vessel 3-dimensional heat conduction is validated against a commercial code. It is found that even though the internal heat flux from the metal layer goes far beyond critical heat flux (CHF) the heat flux from the outermost nodes of the vessel may be maintained below CHF due to massive vessel heat diffusion. The heat diffusion throughout the vessel is more pronounced for relatively low heat generation rate in an oxide pool. Parametric calculations are performed considering thermal conditions such as peak heat flux from a light metal layer, heat generation in an oxide pool and external boiling conditions. The major finding is that the most crucial factor for success of in-vessel retention is not the mass of the molten light metal above the oxide pool but the heat generation rate inside the oxide pool and the 3-dimensional vessel heat transfer provides a much larger minimum vessel wall thickness. (authors)

  10. ALICE HMPID Radiator Vessel

    CERN Document Server

    2003-01-01

    View of the radiator vessels of the ALICE/HMPID mounted on the support frame. Each HMPID module is equipped with 3 indipendent radiator vessels made out of neoceram and fused silica (quartz) windows glued together. The spacers inside the vessel are needed to stand the hydrostatic pressure. http://alice-hmpid.web.cern.ch/alice-hmpid

  11. Fluid sign in the treated bodies after percutaneous vertebroplasty

    International Nuclear Information System (INIS)

    Lin, Chao-Chun; Yen, Pao-Sheng; Wen, Shu-Hui

    2008-01-01

    The aims of this study are to describe non-healing in the treated vertebral body after percutaneous vertebroplasty and analyze the influence of vacuum cleft, location, and severity of collapse on the development of nonunion cement. Of 208 patients (266 treated vertebral bodies) who were treated with percutaneous vertebroplasty from September 2002 to May 2006, 23 patients (41 treated levels) with residual or recurrent pain underwent follow-up magnetic resonance imaging (MRI) study. Retrospective chart review with analysis of preoperative and postoperative MRIs were performed in these 23 patients. In the 41 treated vertebral bodies, 22 of 41 bodies had vacuum cleft found in the preoperative MRI study. Eight of the 22 treated vertebral bodies with preoperative vacuum clefts were found to have fluid between the interface of cement and the residual bone in the collapsed vertebral bodies on follow-up MRI. The adjacent discs of these treated vertebral bodies were upward/downward displaced. The endplate of the adjacent vertebral body exhibited fibrotic change. Treated bodies with vacuum clefts and level A location (T9, T11, T12, and L1) had higher probability of developing nonunion of the cement with statistical significance. The probability of nonunion cement in severe collapsed bodies might be higher than that of union cement in mild collapsed ones, but was not statistically significant. Fluid sign in the treated body represents unhealed bone-cement interface. The location of the treated vertebral body and existence of vacuum cleft in the treated bodies may be important factors influencing the nonunion of cement. (orig.)

  12. The Phonetics of Head and Body Movement in the Realization of American Sign Language Signs.

    Science.gov (United States)

    Tyrone, Martha E; Mauk, Claude E

    2016-01-01

    Because the primary articulators for sign languages are the hands, sign phonology and phonetics have focused mainly on them and treated other articulators as passive targets. However, there is abundant research on the role of nonmanual articulators in sign language grammar and prosody. The current study examines how hand and head/body movements are coordinated to realize phonetic targets. Kinematic data were collected from 5 deaf American Sign Language (ASL) signers to allow the analysis of movements of the hands, head and body during signing. In particular, we examine how the chin, forehead and torso move during the production of ASL signs at those three phonological locations. Our findings suggest that for signs with a lexical movement toward the head, the forehead and chin move to facilitate convergence with the hand. By comparison, the torso does not move to facilitate convergence with the hand for signs located at the torso. These results imply that the nonmanual articulators serve a phonetic as well as a grammatical or prosodic role in sign languages. Future models of sign phonetics and phonology should take into consideration the movements of the nonmanual articulators in the realization of signs. © 2016 S. Karger AG, Basel.

  13. The definition of radiological signs in gastric ulcer and assessment of their validity by inter-observer variation study.

    Science.gov (United States)

    Schulman, A; Simpkins, K C

    1975-07-01

    The initial aim was to program a computer with information on the frequency of radiological signs in benign and malignant gastric ulcers in order to obtain a percentage probability of benignancy or malignancy in succeeding ulcers in clinical practice. However, only four of the many signs described in gastric ulcer were confirmed to be of validity (i.e. reliable existence) by an inter-observer variation study using two observers and the films from 69 barium meal examinations. These were projection or non-projection of the in-profile ulcer, presence or absence of adjacent mucosal folds, good or poor definition of the in-face ulcer's edge, and extension of radiating folds to the in-face ulcer's edge. A few more remained unassessed due to insufficient numbers of relevant cases. It is condluced that: as defined in the literature the majority of radiological signs in this field are of uncertain existence; and the four that were found to be valid do not fully describe the important appearances that may be seen in benign and malignant ulcers and would be inadequate to differentiate them to a sufficiently high degree of probability.

  14. Reactor vessel sealing plug

    International Nuclear Information System (INIS)

    Dooley, R.A.

    1986-01-01

    This invention relates to an apparatus and method for sealing the cold leg nozzles of a nuclear reactor pressure vessel from a remote location during maintenance and inspection of associated steam generators and pumps while the pressure vessel and refueling canal are filled with water. The apparatus includes a sealing plug for mechanically sealing the cold leg nozzle from the inside of a reactor pressure vessel. The sealing plugs include a primary and a secondary O-ring. An installation tool is suspended within the reactor vessel and carries the sealing plug. The tool telescopes to insert the sealing plug within the cold leg nozzle, and to subsequently remove the plug. Hydraulic means are used to activate the sealing plug, and support means serve to suspend the installation tool within the reactor vessel during installation and removal of the sealing plug

  15. New radiation warning sign

    International Nuclear Information System (INIS)

    Mac Kenzie, C.; Mason, C.

    2006-01-01

    Full text: Radiation accidents involving orphan radioactive sources have happened as a result of people not recognizing the radiation trefoil symbol or from being illiterate and not understanding a warning statement on the radiation source. The trefoil symbol has no inherent meaning to people that have not been instructed in its use. A new radiation warning sign, to supplement the existing trefoil symbol, has been developed to address these issues. Human Factors experts, United Nations member states, and members of the international community of radiation protection professionals were consulted for input on the design of a new radiation warning sign that would clearly convey the message of 'Danger- Run Away- Stay Away' when in close proximity to a dangerous source of radiation. Cultural differences of perception on various warning symbols were taken into consideration and arrays of possible signs were developed. The signs were initially tested in international children for identification with the desired message and response. Based on these test results and further input from radiation protection professionals, five warning signs were identified as the most successful in conveying the desired message and response. These five signs were tested internationally in eleven countries by a professional survey company to determine the best sign for this purpose. The conclusion of the international testing is presented. The new radiation warning sign is currently a draft ISO standard under committee review. The design of the propose d radiation warning sign and the proposed implementation strategy outlined in the draft ISO standard is presented. (authors)

  16. Green's Theorem for Sign Data

    OpenAIRE

    Houston, Louis M.

    2012-01-01

    Sign data are the signs of signal added to noise. It is well known that a constant signal can be recovered from sign data. In this paper, we show that an integral over variant signal can be recovered from an integral over sign data based on the variant signal. We refer to this as a generalized sign data average. We use this result to derive a Green's theorem for sign data. Green's theorem is important to various seismic processing methods, including seismic migration. Results in this paper ge...

  17. Transfemoral transcatheter aortic valve implantation in patients with small diseased peripheral vessels

    International Nuclear Information System (INIS)

    Ruparelia, Neil; Buzzatti, Nicola; Romano, Vittorio; Longoni, Matteo; Figini, Fillipo; Montorfano, Matteo; Kawamoto, Hiroyoshi; Miyazaki, Tadashi; Spagnolo, Pietro; Alfieri, Ottavio; Colombo, Antonio; Latib, Azeem

    2015-01-01

    Objectives: The aim of this study was to assess the feasibility, safety and short-term outcomes of transfemoral transcatheter aortic valve implantation (TF-TAVI) in patients with small diseased peripheral vessels. Background: The transfemoral (TF) route for transcatheter aortic valve (TAVI) is the default option due to associated advantages. However, this is limited due to the high prevalence of significant peripheral arterial disease and increased risk of vascular complications. Methods: Of 539 consecutive patients undergoing TAVI in a single Italian center, 23 patients underwent TF-TAVI in the presence of small peripheral vessels as defined by a minimal luminal diameter (MLD) of ≤ 5.5 mm [by computed tomography (CT)] and/or the inability to advance a large-bore sheath. Calcification was defined as being concentric if calcium extended more than 270° around the circumference of the artery. All patients underwent 30-day clinical follow-up. Results: 17 (73.9%) patients underwent peripheral vessel pre-dilatation with a semi-compliant balloon and 6 (26.1%) patients with a Solopath sheath. 6 (26.1%) patients suffered a peri-procedural complication, with 1 patient requiring surgical embolectomy for thrombotic occlusion and the remaining patients successfully managed percutaneously in the catheter laboratory. No patient suffered a vessel perforation or required implantation of a covered stent. At 30-day follow-up, all patients were free of symptoms and signs or symptoms of peripheral vascular disease, with well-functioning TAVI prostheses as evaluated by echocardiography. Conclusions: Performing TF-TAVI is feasible in patients with no other viable vascular access option in the presence of small MLD and calcification of the peripheral vasculature, with any anticipated acute vascular complication managed in the catheter laboratory with established percutaneous techniques. - Highlights: • Small peripheral vessels is regarded as contraindication to transfemoral TAVI.

  18. Transfemoral transcatheter aortic valve implantation in patients with small diseased peripheral vessels

    Energy Technology Data Exchange (ETDEWEB)

    Ruparelia, Neil [San Raffaele Scientific Institute, Milan (Italy); Imperial College, London (United Kingdom); Buzzatti, Nicola; Romano, Vittorio; Longoni, Matteo; Figini, Fillipo; Montorfano, Matteo; Kawamoto, Hiroyoshi; Miyazaki, Tadashi; Spagnolo, Pietro; Alfieri, Ottavio; Colombo, Antonio [San Raffaele Scientific Institute, Milan (Italy); Latib, Azeem, E-mail: info@emocolumbus.it [San Raffaele Scientific Institute, Milan (Italy)

    2015-09-15

    Objectives: The aim of this study was to assess the feasibility, safety and short-term outcomes of transfemoral transcatheter aortic valve implantation (TF-TAVI) in patients with small diseased peripheral vessels. Background: The transfemoral (TF) route for transcatheter aortic valve (TAVI) is the default option due to associated advantages. However, this is limited due to the high prevalence of significant peripheral arterial disease and increased risk of vascular complications. Methods: Of 539 consecutive patients undergoing TAVI in a single Italian center, 23 patients underwent TF-TAVI in the presence of small peripheral vessels as defined by a minimal luminal diameter (MLD) of ≤ 5.5 mm [by computed tomography (CT)] and/or the inability to advance a large-bore sheath. Calcification was defined as being concentric if calcium extended more than 270° around the circumference of the artery. All patients underwent 30-day clinical follow-up. Results: 17 (73.9%) patients underwent peripheral vessel pre-dilatation with a semi-compliant balloon and 6 (26.1%) patients with a Solopath sheath. 6 (26.1%) patients suffered a peri-procedural complication, with 1 patient requiring surgical embolectomy for thrombotic occlusion and the remaining patients successfully managed percutaneously in the catheter laboratory. No patient suffered a vessel perforation or required implantation of a covered stent. At 30-day follow-up, all patients were free of symptoms and signs or symptoms of peripheral vascular disease, with well-functioning TAVI prostheses as evaluated by echocardiography. Conclusions: Performing TF-TAVI is feasible in patients with no other viable vascular access option in the presence of small MLD and calcification of the peripheral vasculature, with any anticipated acute vascular complication managed in the catheter laboratory with established percutaneous techniques. - Highlights: • Small peripheral vessels is regarded as contraindication to transfemoral TAVI.

  19. Pink-color sign in esophageal squamous neoplasia, and speculation regarding the underlying mechanism

    Science.gov (United States)

    Ishihara, Ryu; Kanzaki, Hiromitsu; Iishi, Hiroyasu; Nagai, Kengo; Matsui, Fumi; Yamashina, Takeshi; Matsuura, Noriko; Ito, Takashi; Fujii, Mototsugu; Yamamoto, Sachiko; Hanaoka, Noboru; Takeuchi, Yoji; Higashino, Koji; Uedo, Noriya; Tatsuta, Masaharu; Tomita, Yasuhiko; Ishiguro, Shingo

    2013-01-01

    AIM: To investigate the reasons for the occurrence of the pink-color sign of iodine-unstained lesions. METHODS: In chromoendoscopy, the pink-color sign of iodine-unstained lesions is recognized as useful for the diagnosis of esophageal squamous cell carcinoma. Patients with superficial esophageal neoplasms treated by endoscopic resection were included in the study. Areas of mucosa with and without the pink-color sign were evaluated histologically. The following histologic features that were possibly associated with the pink-color sign were evaluated. The keratinous layer and basal cell layer were classified as present or absent. Cellular atypia was classified as high grade, moderate grade or low grade, based on nuclear irregularity, mitotic figures, loss of polarity, chromatin pattern and nuclear/cytoplasmic ratio. Vascular change was assessed based on dilatation, tortuosity, caliber change and variability in shape. Vessels with these four findings were classified as positive for vascular change. Endoscopic images of the lesions were captured immediately after iodine staining, 2-3 min after iodine staining and after complete fading of iodine staining. Quantitative analysis of color changes after iodine staining was also performed. RESULTS: A total of 61 superficial esophageal neoplasms in 54 patients were included in the study. The lesions were located in the cervical esophagus in one case, the upper thoracic esophagus in 10 cases, the mid-thoracic esophagus in 33 cases, and the lower thoracic esophagus in 17 cases. The median diameter of the lesions was 20 mm (range: 2-74 mm). Of the 61 lesions, 28 were classified as pink-color sign positive and 33 as pink-color sign negative. The histologic diagnosis was high-grade intraepithelial neoplasia (HGIN) or cancer invading into the lamina propria in 26 of the 28 pink-color sign positive lesions. There was a significant association between pink-color sign positive epithelium and HGIN or invasive cancer (P = 0

  20. Variable length adjacent partitioning for PTS based PAPR reduction of OFDM signal

    International Nuclear Information System (INIS)

    Ibraheem, Zeyid T.; Rahman, Md. Mijanur; Yaakob, S. N.; Razalli, Mohammad Shahrazel; Kadhim, Rasim A.

    2015-01-01

    Peak-to-Average power ratio (PAPR) is a major drawback in OFDM communication. It leads the power amplifier into nonlinear region operation resulting into loss of data integrity. As such, there is a strong motivation to find techniques to reduce PAPR. Partial Transmit Sequence (PTS) is an attractive scheme for this purpose. Judicious partitioning the OFDM data frame into disjoint subsets is a pivotal component of any PTS scheme. Out of the existing partitioning techniques, adjacent partitioning is characterized by an attractive trade-off between cost and performance. With an aim of determining effects of length variability of adjacent partitions, we performed an investigation into the performances of a variable length adjacent partitioning (VL-AP) and fixed length adjacent partitioning in comparison with other partitioning schemes such as pseudorandom partitioning. Simulation results with different modulation and partitioning scenarios showed that fixed length adjacent partition had better performance compared to variable length adjacent partitioning. As expected, simulation results showed a slightly better performance of pseudorandom partitioning technique compared to fixed and variable adjacent partitioning schemes. However, as the pseudorandom technique incurs high computational complexities, adjacent partitioning schemes were still seen as favorable candidates for PAPR reduction

  1. Variable length adjacent partitioning for PTS based PAPR reduction of OFDM signal

    Energy Technology Data Exchange (ETDEWEB)

    Ibraheem, Zeyid T.; Rahman, Md. Mijanur; Yaakob, S. N.; Razalli, Mohammad Shahrazel; Kadhim, Rasim A. [School of Computer and Communication Engineering, Universiti Malaysia Perlis, 02600 Arau, Perlis (Malaysia)

    2015-05-15

    Peak-to-Average power ratio (PAPR) is a major drawback in OFDM communication. It leads the power amplifier into nonlinear region operation resulting into loss of data integrity. As such, there is a strong motivation to find techniques to reduce PAPR. Partial Transmit Sequence (PTS) is an attractive scheme for this purpose. Judicious partitioning the OFDM data frame into disjoint subsets is a pivotal component of any PTS scheme. Out of the existing partitioning techniques, adjacent partitioning is characterized by an attractive trade-off between cost and performance. With an aim of determining effects of length variability of adjacent partitions, we performed an investigation into the performances of a variable length adjacent partitioning (VL-AP) and fixed length adjacent partitioning in comparison with other partitioning schemes such as pseudorandom partitioning. Simulation results with different modulation and partitioning scenarios showed that fixed length adjacent partition had better performance compared to variable length adjacent partitioning. As expected, simulation results showed a slightly better performance of pseudorandom partitioning technique compared to fixed and variable adjacent partitioning schemes. However, as the pseudorandom technique incurs high computational complexities, adjacent partitioning schemes were still seen as favorable candidates for PAPR reduction.

  2. Signed languages and globalization

    NARCIS (Netherlands)

    Hiddinga, A.; Crasborn, O.

    2011-01-01

    Deaf people who form part of a Deaf community communicate using a shared sign language. When meeting people from another language community, they can fall back on a flexible and highly context-dependent form of communication called international sign, in which shared elements from their own sign

  3. Reactor vessel stud closure system

    International Nuclear Information System (INIS)

    Spiegelman, S.R.; Salton, R.B.; Beer, R.W.; Malandra, L.J.; Cognevich, M.L.

    1982-01-01

    A quick-acting stud tensioner apparatus for enabling the loosening or tightening of a stud nut on a reactor vessel stud. The apparatus is adapted to engage the vessel stud by closing a gripper around an upper end of the vessel stud when the apparatus is seated on the stud. Upon lifting the apparatus, the gripper releases the vessel stud so that the apparatus can be removed

  4. On the temporal dynamics of sign production: An ERP study in Catalan Sign Language (LSC).

    Science.gov (United States)

    Baus, Cristina; Costa, Albert

    2015-06-03

    This study investigates the temporal dynamics of sign production and how particular aspects of the signed modality influence the early stages of lexical access. To that end, we explored the electrophysiological correlates associated to sign frequency and iconicity in a picture signing task in a group of bimodal bilinguals. Moreover, a subset of the same participants was tested in the same task but naming the pictures instead. Our results revealed that both frequency and iconicity influenced lexical access in sign production. At the ERP level, iconicity effects originated very early in the course of signing (while absent in the spoken modality), suggesting a stronger activation of the semantic properties for iconic signs. Moreover, frequency effects were modulated by iconicity, suggesting that lexical access in signed language is determined by the iconic properties of the signs. These results support the idea that lexical access is sensitive to the same phenomena in word and sign production, but its time-course is modulated by particular aspects of the modality in which a lexical item will be finally articulated. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Containment vessel drain system

    Science.gov (United States)

    Harris, Scott G.

    2018-01-30

    A system for draining a containment vessel may include a drain inlet located in a lower portion of the containment vessel. The containment vessel may be at least partially filled with a liquid, and the drain inlet may be located below a surface of the liquid. The system may further comprise an inlet located in an upper portion of the containment vessel. The inlet may be configured to insert pressurized gas into the containment vessel to form a pressurized region above the surface of the liquid, and the pressurized region may operate to apply a surface pressure that forces the liquid into the drain inlet. Additionally, a fluid separation device may be operatively connected to the drain inlet. The fluid separation device may be configured to separate the liquid from the pressurized gas that enters the drain inlet after the surface of the liquid falls below the drain inlet.

  6. Superior mesenteric vein rotation: a CT sign of midgut malrotation

    International Nuclear Information System (INIS)

    Nichols, D.M.; Li, D.K.

    1983-01-01

    Computed tomography (CT) of the pancreas, with its excellent display of peripancreatic anatomy, allows visualization of the major vessels entering the mesenteric root. In scans of the normal upper abdomen obtained at or just below the level of the uncinate process of the pancreas, the proximal superior mesenteric vein (SMV) easily can be identified lying on the right ventral aspect of the superior mesenteric artery (SMA). The authors have observed a characteristic abnormality in this normal vascular arrangement on CT scans of the pancreas in three adult patients with suspected chronic pancreatitis who were subsequently proved to have midgut malrotation. They called this the SMV rotation sign and believe that its detection even on CT scans limited to the level of the pancreas should alert the radiologist to the presence of a midgut malrotation that may have been unsuspected

  7. Autocorrelation descriptor improvements for QSAR: 2DA_Sign and 3DA_Sign

    Science.gov (United States)

    Sliwoski, Gregory; Mendenhall, Jeffrey; Meiler, Jens

    2016-03-01

    Quantitative structure-activity relationship (QSAR) is a branch of computer aided drug discovery that relates chemical structures to biological activity. Two well established and related QSAR descriptors are two- and three-dimensional autocorrelation (2DA and 3DA). These descriptors encode the relative position of atoms or atom properties by calculating the separation between atom pairs in terms of number of bonds (2DA) or Euclidean distance (3DA). The sums of all values computed for a given small molecule are collected in a histogram. Atom properties can be added with a coefficient that is the product of atom properties for each pair. This procedure can lead to information loss when signed atom properties are considered such as partial charge. For example, the product of two positive charges is indistinguishable from the product of two equivalent negative charges. In this paper, we present variations of 2DA and 3DA called 2DA_Sign and 3DA_Sign that avoid information loss by splitting unique sign pairs into individual histograms. We evaluate these variations with models trained on nine datasets spanning a range of drug target classes. Both 2DA_Sign and 3DA_Sign significantly increase model performance across all datasets when compared with traditional 2DA and 3DA. Lastly, we find that limiting 3DA_Sign to maximum atom pair distances of 6 Å instead of 12 Å further increases model performance, suggesting that conformational flexibility may hinder performance with longer 3DA descriptors. Consistent with this finding, limiting the number of bonds in 2DA_Sign from 11 to 5 fails to improve performance.

  8. Non-flood season neap tides in the Yangtze estuary offshore: Flow mixing processes and its potential impacts on adjacent wetlands

    Science.gov (United States)

    Wei, Taoyuan; Wang, Zhanghua; Chen, Jing; Li, Maotian

    2018-02-01

    How flow mixing process influences the wetlands of the Yangtze Estuary is still poorly understood. Hydrological fieldwork was conducted on five vessel-anchored sites (S1-S2; M1-M2-M3) near the major wetlands of the Yangtze Estuary offshore (121°57‧-122°30‧E, 30°50‧-31°23‧N) on May 8-11 2004, to examine the dynamics of neap tides in the non-flood season of the Yangtze (∼24, 700 m3s-1 at Datong) and their impacts on adjacent wetlands. Based on the measurement of the acoustic Doppler current profiler (aDcp), direct-reading current meter and optical backscattering sensor (OBS-3A), two flow patterns were revealed: 1) well mixing flow pattern caused by the turbulent tidal currents, and 2) weak mixing flow pattern resulted by the estuarine circulation in the North Port of the estuary. The characteristics of such different flow patterns were analyzed and resultant sediment dispersals were discussed in relation to the adjacent wetlands. It is suggested that the estuarine circulation might be the important process to nourish the eastern wetland of the Yangtze Estuary which has been neglected before.

  9. 33 CFR 80.1395 - Puget Sound and adjacent waters.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Puget Sound and adjacent waters. 80.1395 Section 80.1395 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... waters. The 72 COLREGS shall apply on all waters of Puget Sound and adjacent waters, including Lake Union...

  10. Mobile nuclear reactor containment vessel

    International Nuclear Information System (INIS)

    Thompson, R.E.; Spurrier, F.R.; Jones, A.R.

    1978-01-01

    A containment vessel for use in mobile nuclear reactor installations is described. The containment vessel completely surrounds the entire primary system, and is located as close to the reactor primary system components as is possible in order to minimize weight. In addition to being designed to withstand a specified internal pressure, the containment vessel is also designed to maintain integrity as a containment vessel in case of a possible collision accident

  11. Thermal Behavior of the Reactor Vessel Penetration Under External Vessel Cooling During a Severe Accident

    International Nuclear Information System (INIS)

    Kang, Kyoung-Ho; Park, Rae-Joon; Kim, Jong-Tae; Min, Byung-Tae; Lee, Ki-Young; Kim, Sang-Baik

    2004-01-01

    Experimental and analytical studies on the thermal behavior of reactor vessel penetration have been performed under external vessel cooling during a severe accident in the Korean next-generation reactor APR1400. Two types of tests, SUS-EXT and SUS-DRY with and without external vessel cooling, respectively, have been performed using sustained heating by an induction heater. Three tests have been carried out varying the cooling conditions at the vessel outer surface in the SUS-EXT tests. The experimental results have been thermally estimated using the LILAC computer code. The experimental results indicate that the inner surface of the vessel was ablated by the 45-mm thickness in the SUS-DRY test. Despite the total ablation of the welding material, the penetration was not ejected outside the vessel, which could be attributed to the thermal expansion of the penetration. Unlike the SUS-DRY test, the thickness of the ablation was ∼15 to 20 mm at most, so the welding was preserved in the SUS-EXT tests. It is concluded from the experimental results that the external vessel cooling highly affected the ablation configuration and the thermal behaviors of the vessel and the penetration. An increase in coolant mass flow rate from 0.047 to 0.152 kg/s had effects on the thermal behavior of the lower head vessel and penetration in the SUS-EXT tests. The LILAC analytical results on temperature distribution and ablation depth in the lower head vessel and penetration were very similar to the experimental results

  12. [Problems with certification of work capability for people with symptoms of functional and organic diseases of cerebral vessels].

    Science.gov (United States)

    Polakowska, B

    1993-01-01

    The problems of certifying work capability for people with the symptoms of functional and organic diseases of cerebral vessels were investigated basing on the documentation of 470 medical consultations performed at the Out-Patient Department of Occupational Diseases, the Institute of Occupational Medicine, Lodz, Poland. The certification was most difficult in people with angiogenic headache, symptoms of transient cerebral ischaemia and apoplexy with non-intensive deficiency signs. The certification criteria most appropriate for that group of diseases were formulated.

  13. British Sign Name Customs

    Science.gov (United States)

    Day, Linda; Sutton-Spence, Rachel

    2010-01-01

    Research presented here describes the sign names and the customs of name allocation within the British Deaf community. While some aspects of British Sign Language sign names and British Deaf naming customs differ from those in most Western societies, there are many similarities. There are also similarities with other societies outside the more…

  14. Negation switching invariant signed graphs

    Directory of Open Access Journals (Sweden)

    Deepa Sinha

    2014-04-01

    Full Text Available A signed graph (or, $sigraph$ in short is a graph G in which each edge x carries a value $\\sigma(x \\in \\{-, +\\}$ called its sign. Given a sigraph S, the negation $\\eta(S$ of the sigraph S is a sigraph obtained from S by reversing the sign of every edge of S. Two sigraphs $S_{1}$ and $S_{2}$ on the same underlying graph are switching equivalent if it is possible to assign signs `+' (`plus' or `-' (`minus' to vertices of $S_{1}$ such that by reversing the sign of each of its edges that has received opposite signs at its ends, one obtains $S_{2}$. In this paper, we characterize sigraphs which are negation switching invariant and also see for what sigraphs, S and $\\eta (S$ are signed isomorphic.

  15. Nuclear reactor vessel decontamination systems

    International Nuclear Information System (INIS)

    McGuire, P. J.

    1985-01-01

    There is disclosed in the present application, a decontamination system for reactor vessels. The system is operatable without entry by personnel into the contaminated vessel before the decontamination operation is carried out and comprises an assembly which is introduced into the vertical cylindrical vessel of the typical boiling water reactor through the open top. The assembly includes a circular track which is centered by guideways permanently installed in the reactor vessel and the track guides opposed pairs of nozzles through which water under very high pressure is directed at the wall for progressively cutting and sweeping a tenacious radioactive coating as the nozzles are driven around the track in close proximity to the vessel wall. The whole assembly is hoisted to a level above the top of the vessel by a crane, outboard slides on the assembly brought into engagement with the permanent guideways and the assembly progressively lowered in the vessel as the decontamination operation progresses. The assembly also includes a low pressure nozzle which forms a spray umbrella above the high pressure nozzles to contain radioactive particles dislodged during the decontamination

  16. What is cerebral small vessel disease?

    International Nuclear Information System (INIS)

    Onodera, Osamu

    2011-01-01

    An accumulating amount of evidence suggests that the white matter hyperintensities on T 2 weighted brain magnetic resonance imaging predict an increased risk of dementia and gait disturbance. This state has been proposed as cerebral small vessel disease, including leukoaraiosis, Binswanger's disease, lacunar stroke and cerebral microbleeds. However, the concept of cerebral small vessel disease is still obscure. To understand the cerebral small vessel disease, the precise structure and function of cerebral small vessels must be clarified. Cerebral small vessels include several different arteries which have different anatomical structures and functions. Important functions of the cerebral small vessels are blood-brain barrier and perivasucular drainage of interstitial fluid from the brain parenchyma. Cerebral capillaries and glial endfeet, take an important role for these functions. However, the previous pathological investigations on cerebral small vessels have focused on larger arteries than capillaries. Therefore little is known about the pathology of capillaries in small vessel disease. The recent discoveries of genes which cause the cerebral small vessel disease indicate that the cerebral small vessel diseases are caused by a distinct molecular mechanism. One of the pathological findings in hereditary cerebral small vessel disease is the loss of smooth muscle cells, which is an also well-recognized finding in sporadic cerebral small vessel disease. Since pericytes have similar character with the smooth muscle cells, the pericytes should be investigated in these disorders. In addition, the loss of smooth muscle cells may result in dysfunction of drainage of interstitial fluid from capillaries. The precise correlation between the loss of smooth muscle cells and white matter disease is still unknown. However, the function that is specific to cerebral small vessel may be associated with the pathogenesis of cerebral small vessel disease. (author)

  17. Signs of political economy

    Directory of Open Access Journals (Sweden)

    Bernard Lamizet

    2015-12-01

    Full Text Available Like any political system, economy is a system of signs and representations. The Semiotics of economy elaborates its analytical methods to interpret such signs, which give meaning to the economy by representing its performances in public debate and in the media. Four major features distinguish the Semiotics of political economy from other semiotic forms or other systems of information and political representation. First of all, the relationship between the signification of the economy and the real or the imaginary phenomena to which they refer always pertains to the order of values. The second characteristic of economic signs is the significance of the state of lack they express. The third characteristic of signs of the economy is the form of sign production, which can be designated by the concept of emission of signs and their diffusion. Finally, as all signs, the economic sign is arbitrary. In the field of Economics, such arbitrariness does not imply that the Subject is free to superimpose whatever value to the signs themselves, but refers to the rupture between the world and its possible transformation. The very meaning of the word economy is here at stake. Oikos, in Greek (the term from which the word economy is derived refers to a known, familiar space. Economy transforms the real, natural world into a symbolic social world, into a world of relations with others whom we recognise and whose actions are relatively predictable. It might be useful to consider the contemporary issue of debt, its implications and its multiple meanings, which includes both the ethical and moral dimension of the condemnation of debt as well as the imaginary political dimension based on the expression of an idea of independence.

  18. Planning Sign Languages: Promoting Hearing Hegemony? Conceptualizing Sign Language Standardization

    Science.gov (United States)

    Eichmann, Hanna

    2009-01-01

    In light of the absence of a codified standard variety in British Sign Language and German Sign Language ("Deutsche Gebardensprache") there have been repeated calls for the standardization of both languages primarily from outside the Deaf community. The paper is based on a recent grounded theory study which explored perspectives on sign…

  19. Signs of the arctic: Typological aspects of Inuit Sign Language

    NARCIS (Netherlands)

    Schuit, J.M.

    2014-01-01

    In this thesis, the native sign language used by deaf Inuit people is described. Inuit Sign Language (IUR) is used by less than 40 people as their sole means of communication, and is therefore highly endangered. Apart from the description of IUR as such, an additional goal is to contribute to the

  20. Ranks of dense alternating sign matrices and their sign patterns

    Czech Academy of Sciences Publication Activity Database

    Fiedler, Miroslav; Gao, W.; Hall, F.J.; Jing, G.; Li, Z.; Stroev, M.

    2015-01-01

    Roč. 471, April (2015), s. 109-121 ISSN 0024-3795 R&D Projects: GA ČR(CZ) GA14-07880S Institutional support: RVO:67985840 Keywords : alternating sign matrix * dense matrix * sign pattern matrix Subject RIV: BA - General Mathematics Impact factor: 0.965, year: 2015 http://www.sciencedirect.com/science/article/pii/S0024379515000257

  1. Nuclear reactor vessel inspection apparatus

    International Nuclear Information System (INIS)

    Blackstone, E.G.; Lofy, R.A.; Williams, L.P.

    1979-01-01

    Apparatus for the in situ inspection of a nuclear reactor vessel to detect the location and character of flaws in the walls of the vessel, in the welds joining the various sections of the vessel, in the welds joining attachments such as nozzles, elbows and the like to the reactor vessel and in such attachments wherein an inspection head carrying one or more ultrasonic transducers follows predetermined paths in scanning the various reactor sections, welds and attachments

  2. Sociolinguistic Variation and Change in British Sign Language Number Signs: Evidence of Leveling?

    Science.gov (United States)

    Stamp, Rose; Schembri, Adam; Fenlon, Jordan; Rentelis, Ramas

    2015-01-01

    This article presents findings from the first major study to investigate lexical variation and change in British Sign Language (BSL) number signs. As part of the BSL Corpus Project, number sign variants were elicited from 249 deaf signers from eight sites throughout the UK. Age, school location, and language background were found to be significant…

  3. Occult inflammatory breast cancer: review of clinical, mammographic, US and pathologic signs

    International Nuclear Information System (INIS)

    Cumo, Francesca; Gaioni, Maria Berenice; Bonetti, Franco; Manfrin, Erminia; Remo, Andrea; Pattaro, Christian; Policlinico G.B. Rossi, Verona

    2005-01-01

    Purpose: To examine the clinical, radiologic and pathologic findings of occult inflammatory breast cancer (OIBC) in order to identify features useful for diagnosis. Materials and methods: We retrospectively reviewed the records of 19 women with OIBC observed at our Department between 1992 and 2001. We analysed the clinical history, mammographic, ultrasonographic, and pathologic findings and investigated overall survival (OS), prognostic variables and radio-pathologic correlations. Results: The most common mammographic findings were: diffusely density (52.63%), trabecular thickening (42.1%), mass (36.84%). The most common US findings were axillary lymphadenopathy (68,75%), skin thickening (43.75%) and mass (56.25%). At least one inflammatory sign was found in 14 women (74%) at mammography (subcutaneous thickening, trabecular thickening, diffuse increase of density) or at US (subcutaneous thickening, diffuse increase in echogenicity due to oedema, lymph vessel dilatation). Estrogen receptors (ER) were present in 63.2% and Progesterone receptors (PgR) in 36.8%. Significant prognostic variables were ER and Ki 67. Conclusions: The typical radiological pattern of clinical inflammatory breast carcinoma is less frequently present in OIBC; nevertheless the radiologist must pay attention because frequently OIBC presents just one radiological sign and this should be enough for a diagnostic suspicion. Moreover, the absence of clinical and radiological inflammatory signs does not exclude inflammatory breasts cancer because OIBC can manifest at imaging as a mass or isolated calcification. ER and PgR are positive in a high percentage of patients and confirm that OIBC has a better prognosis that clinical inflammatory breast cancer [it

  4. Flexible Composite-Material Pressure Vessel

    Science.gov (United States)

    Brown, Glen; Haggard, Roy; Harris, Paul A.

    2003-01-01

    A proposed lightweight pressure vessel would be made of a composite of high-tenacity continuous fibers and a flexible matrix material. The flexibility of this pressure vessel would render it (1) compactly stowable for transport and (2) more able to withstand impacts, relative to lightweight pressure vessels made of rigid composite materials. The vessel would be designed as a structural shell wherein the fibers would be predominantly bias-oriented, the orientations being optimized to make the fibers bear the tensile loads in the structure. Such efficient use of tension-bearing fibers would minimize or eliminate the need for stitching and fill (weft) fibers for strength. The vessel could be fabricated by techniques adapted from filament winding of prior composite-material vessels, perhaps in conjunction with the use of dry film adhesives. In addition to the high-bias main-body substructure described above, the vessel would include a low-bias end substructure to complete coverage and react peak loads. Axial elements would be overlaid to contain damage and to control fiber orientation around side openings. Fiber ring structures would be used as interfaces for connection to ancillary hardware.

  5. Ionizing radiations and blood vessels

    International Nuclear Information System (INIS)

    Vorob'ev, E.I.; Stepanov, R.P.

    1985-01-01

    Data on phenomeology of radiation changes of blood vessels are systemized and the authors' experience is generalyzed. A critical analysis of modern conceptions on processes resulting in vessel structure damage after irradiation, is given. Special attention is paid to reparation and compensation of radiation injury of vessels

  6. Adolf Kussmaul and Kussmaul's sign

    Directory of Open Access Journals (Sweden)

    Navreet Singh

    2015-01-01

    Full Text Available Kussmaul's has provided us with three important signs: Pulses paradoxus, Kussmaul's sign and Kussmaul Breathing. This article discusses Kussmaul's sign, its discovery, first description, pathophyiology and exceptions.

  7. Acrylic vessel cleaning tests

    International Nuclear Information System (INIS)

    Earle, D.; Hahn, R.L.; Boger, J.; Bonvin, E.

    1997-01-01

    The acrylic vessel as constructed is dirty. The dirt includes blue tape, Al tape, grease pencil, gemak, the glue or residue form these tapes, finger prints and dust of an unknown composition but probably mostly acrylic dust. This dirt has to be removed and once removed, the vessel has to be kept clean or at least to be easily cleanable at some future stage when access becomes much more difficult. The authors report on the results of a series of tests designed: (a) to prepare typical dirty samples of acrylic; (b) to remove dirt stuck to the acrylic surface; and (c) to measure the optical quality and Th concentration after cleaning. Specifications of the vessel call for very low levels of Th which could come from tape residues, the grease pencil, or other sources of dirt. This report does not address the concerns of how to keep the vessel clean after an initial cleaning and during the removal of the scaffolding. Alconox is recommended as the cleaner of choice. This acrylic vessel will be used in the Sudbury Neutrino Observatory

  8. DIFFERENCES BETWEEN AMERICAN SIGN LANGUAGE (ASL AND BRITISH SIGN LANGUAGE (BSL

    Directory of Open Access Journals (Sweden)

    Zora JACHOVA

    2008-06-01

    Full Text Available In the communication of deaf people between them­selves and hearing people there are three ba­sic as­pects of interaction: gesture, finger signs and writing. The gesture is a conditionally agreed manner of communication with the help of the hands followed by face and body mimic. The ges­ture and the move­ments pre-exist the speech and they had the purpose to mark something, and later to emphasize the speech expression.Stokoe was the first linguist that realised that the signs are not a whole that can not be analysed. He analysed signs in insignificant parts that he called “chemeres”, and many linguists today call them pho­nemes. He created three main phoneme catego­ries: hand position, location and movement.Sign languages as spoken languages have back­ground from the distant past. They developed par­allel with the development of spoken language and undertook many historical changes. Therefore, to­day they do not represent a replacement of the spoken language, but are languages themselves in the real sense of the word.Although the structures of the English language used in USA and in Great Britain is the same, still their sign languages-ASL and BSL are different.

  9. Local adjacency metric dimension of sun graph and stacked book graph

    Science.gov (United States)

    Yulisda Badri, Alifiah; Darmaji

    2018-03-01

    A graph is a mathematical system consisting of a non-empty set of nodes and a set of empty sides. One of the topics to be studied in graph theory is the metric dimension. Application in the metric dimension is the navigation robot system on a path. Robot moves from one vertex to another vertex in the field by minimizing the errors that occur in translating the instructions (code) obtained from the vertices of that location. To move the robot must give different instructions (code). In order for the robot to move efficiently, the robot must be fast to translate the code of the nodes of the location it passes. so that the location vertex has a minimum distance. However, if the robot must move with the vertex location on a very large field, so the robot can not detect because the distance is too far.[6] In this case, the robot can determine its position by utilizing location vertices based on adjacency. The problem is to find the minimum cardinality of the required location vertex, and where to put, so that the robot can determine its location. The solution to this problem is the dimension of adjacency metric and adjacency metric bases. Rodrguez-Velzquez and Fernau combine the adjacency metric dimensions with local metric dimensions, thus becoming the local adjacency metric dimension. In the local adjacency metric dimension each vertex in the graph may have the same adjacency representation as the terms of the vertices. To obtain the local metric dimension of values in the graph of the Sun and the stacked book graph is used the construction method by considering the representation of each adjacent vertex of the graph.

  10. Development of PWR pressure vessel steels

    International Nuclear Information System (INIS)

    Druce, S.; Edwards, B.

    1982-01-01

    Requirements to be met by vessel steels for pressurized water reactors are analyzed. Chemicat composition of low-alloyed steels, mechanical properties of sheets and forgings made of these steels and changes in the composition and properties over the wall thickness of the reactor vessel are presented. Problems of the vessel manufacturing including welding and heat treatment processes of sheets and forgings are considered. Special attention is paid to steel embrittlement during vessel fabrication and operation (radiation embrittlement, thermal embrittlement). The role of non-metal inclusions and their effect on anisotropy of fracture toughness is discussed. Possible developments of vessel steels and procedures for producing reactor vessels are reviewed

  11. Development of PWR pressure vessel steels

    Energy Technology Data Exchange (ETDEWEB)

    Druce, S.; Edwards, B.

    1982-01-01

    Requirements to be met by vessel steels for pressurized water reactors are analyzed. Chemicat composition of low-alloyed steels, mechanical properties of sheets and forgings made of these steels and changes in the composition and properties over the wall thickness of the reactor vessel are presented. Problems of the vessel manufacturing including welding and heat treatment processes of sheets and forgings are considered. Special attention is paid to steel embrittlement during vessel fabrication and operation (radiation embrittlement, thermal embrittlement). The role of non-metal inclusions and their effect on anisotropy of fracture toughness is discussed. Possible developments of vessel steels and procedures for producing reactor vessels are reviewed.

  12. On Mathematical Optimization for the Visualization of Frequencies and Adjacencies as Rectangular Maps

    DEFF Research Database (Denmark)

    Carrizosa, Emilio; Guerrero, Vanesa; Morales, Dolores Romero

    2018-01-01

    individuals as adjacent rectangular portions as possible and adding as few false adjacencies, i.e., adjacencies between rectangular portions corresponding to non-adjacent individuals, as possible. We formulate this visualization problem as a Mixed Integer Linear Programming (MILP) model. We propose......In this paper we address the problem of visualizing a frequency distribution and an adjacency relation attached to a set of individuals. We represent this information using a rectangular map, i.e., a subdivision of a rectangle into rectangular portions so that each portion is associated with one...

  13. Clay Corner: Recreating Chinese Bronze Vessels.

    Science.gov (United States)

    Gamble, Harriet

    1998-01-01

    Presents a lesson where students make faux Chinese bronze vessels through slab or coil clay construction after they learn about the history, function, and design of these vessels. Utilizes a variety of glaze finishes in order to give the vessels an aged look. Gives detailed guidelines for creating the vessels. (CMK)

  14. Gammatography of thick lead vessels

    International Nuclear Information System (INIS)

    Raghunath, V.M.; Bhatnagar, P.K.; Sundaram, V.M.

    1979-01-01

    Radiography, scintillation and GM counting and dose measurements using ionisation chamber equipment are commonly used for detecting flaws/voids in materials. The first method is mostly used for steel vessels and to a lesser extent thin lead vessels also and is essentially qualitative. Dose measuring techniques are used for very thick and large lead vessels for which high strength radioactive sources are required, with its inherent handling problems. For vessels of intermediate thicknesses, it is ideal to use a small strength source and a GM or scintillation counter assembly. At the Reactor Research Centre, Kalpakkam, such a system was used for checking three lead vessels of thicknesses varying from 38mm to 65mm. The tolerances specified were +- 4% variation in lead thickness. The measurements also revealed the non concentricity of one vessel which had a thickness varying from 38mm to 44mm. The second vessel was patently non-concentric and the dimensional variation was truly reproduced in the measurements. A third vessel was fabricated with careful control of dimensions and the measurements exhibited good concentricity. Small deviations were observed, attributable to imperfect bondings between steel and lead. This technique has the following advantages: (a) weaker sources used result in less handling problems reducing the personnel exposures considerably; (b) the sensitivity of the instrument is quite good because of better statistics; (c) the time required for scanning a small vessel is more, but a judicious use of a scintillometer for initial fast scan will help in reducing the total scanning time; (d) this method can take advantage of the dimensional variations themselves to get the calibration and to estimate the deviations from specified tolerances. (auth.)

  15. Smooth muscle cell recruitment to lymphatic vessels requires PDGFB and impacts vessel size but not identity.

    Science.gov (United States)

    Wang, Yixin; Jin, Yi; Mäe, Maarja Andaloussi; Zhang, Yang; Ortsäter, Henrik; Betsholtz, Christer; Mäkinen, Taija; Jakobsson, Lars

    2017-10-01

    Tissue fluid drains through blind-ended lymphatic capillaries, via smooth muscle cell (SMC)-covered collecting vessels into venous circulation. Both defective SMC recruitment to collecting vessels and ectopic recruitment to lymphatic capillaries are thought to contribute to vessel failure, leading to lymphedema. However, mechanisms controlling lymphatic SMC recruitment and its role in vessel maturation are unknown. Here, we demonstrate that platelet-derived growth factor B (PDGFB) regulates lymphatic SMC recruitment in multiple vascular beds. PDGFB is selectively expressed by lymphatic endothelial cells (LECs) of collecting vessels. LEC-specific deletion of Pdgfb prevented SMC recruitment causing dilation and failure of pulsatile contraction of collecting vessels. However, vessel remodelling and identity were unaffected. Unexpectedly, Pdgfb overexpression in LECs did not induce SMC recruitment to capillaries. This was explained by the demonstrated requirement of PDGFB extracellular matrix (ECM) retention for lymphatic SMC recruitment, and the low presence of PDGFB-binding ECM components around lymphatic capillaries. These results demonstrate the requirement of LEC-autonomous PDGFB expression and retention for SMC recruitment to lymphatic vessels, and suggest an ECM-controlled checkpoint that prevents SMC investment of capillaries, which is a common feature in lymphedematous skin. © 2017. Published by The Company of Biologists Ltd.

  16. On Pathos Adjacency Cut Vertex Jump Graph of a Tree

    OpenAIRE

    Nagesh.H.M; R.Chandrasekhar

    2014-01-01

    In this paper the concept of pathos adjacency cut vertex jump graph PJC(T) of a tree T is introduced. We also present a characterization of graphs whose pathos adjacency cut vertex jump graphs are planar, outerplanar, minimally non-outerplanar, Eulerian and Hamiltonian.

  17. Lubricant coating of dowel for the ITER vacuum vessel gravity support

    Energy Technology Data Exchange (ETDEWEB)

    Kim, B.Y. [ITER Korea, National Fusion Research Institute, Daejeon 305-333 (Korea, Republic of); Ahn, H.J., E-mail: hjahn@nfri.re.kr [ITER Korea, National Fusion Research Institute, Daejeon 305-333 (Korea, Republic of); Bak, J.S. [ITER Korea, National Fusion Research Institute, Daejeon 305-333 (Korea, Republic of); Choi, C.H.; Ioki, K. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Zauner, C. [KRP-Mechatec Engineering GbR, 85748 Garching b, Muenchen (Germany)

    2012-08-15

    The ITER vacuum vessel gravity supports located in the lower level shall sustain loads in radial, toroidal and vertical directions. The hinge type VVGS consists of two hinges, upper and lower blocks and dowels. In order to develop the design concept and verify the structural integrity of the hinge system, the design analysis has been performed in detail. Inclination of 15 Degree-Sign for the hinge based supporting system was introduced to provide centering force to make stable equilibrium state of the vacuum vessel. Due to this inclination the hinges are rotated by the radial expansion of the VV during operation and baking, respectively. If a dowel is seized in the hinge, the supporting system can be highly stressed due to the restrained displacement in the seized dowel. Therefore, solid lubricant coatings were suggested on dowels in order to avoid seizing in the sliding area. In this work, several sets of coupons were made with different coating materials to investigate the effect according to the selection of coating material. Also, a test facility was designed to cover the ITER relevant loading and boundary conditions, e.g. vacuum condition, temperature, contact pressure, cycles, etc. From those test results, the optimized coating method was found to avoid seizure of dowel in the ITER VVGS.

  18. Conceptual design of an in-vessel inspection robotic system for Tokamak environment

    International Nuclear Information System (INIS)

    Kumar, Prabhat; Raju, Daniel; Ranjan, Vaibhav; Patel, Prateek; Dave, Jatinkumar; Naik, Mehul

    2013-01-01

    An in-vessel inspection robotic system has been conceptualized for operation inside a tokamak vessel. The robotic system is envisaged to comprise of a robotic arm, end-effector, microcontroller and wireless communication system. The end-effector is envisaged to be a special purpose camera for in-situ inspection between plasma shots. The three-link robotic arm, designed for ITER-like environment, has 4 revolute joints- 3 providing manipulation in poloidal plane and the fourth one providing limited movement in adjacent toroidal planes. This paper provides the conceptual design of the system along with kinematic analysis of robotic arm. Solutions have been derived for forward and inverse kinematic models and the Jacobian matrix for the robotic arm linkage. In forward kinematic model, given a set of joint-link parameters, the position and orientation of end-effector are determined with respect to a reference frame. In inverse kinematic model, given the specified position and orientation of end-effector with respect to a reference frame, a set of joint variables are derived that would bring the end-effector into the required posture. Using Jacobian matrix, the relation between the end-effector velocity and the joint velocity of a manipulator is obtained i.e. given the individual joint velocity; the end-effector velocity is obtained. A CAD model has been generated using CATIA to simulate the kinematic model and carry out computational stress analysis. (author)

  19. Fracture probability evaluation of a LWR pressure vessel

    International Nuclear Information System (INIS)

    Grandemange, J.; Pellissier-Tanon, A.; Quero, J.; Carnino, A.; Dufresne, J.

    1978-01-01

    Fracture probability evaluation, of a LWR pressure vessel have been performed in the past, using statistical data from conventional plant. A more accurate evaluation has been requested in 1976 from the SCSIN to the CEA. With this object, a joint collaboration agreement has been signed between CEA, EURATOM/ISPRA and FRAMATOME. The whole program proceeding from this agreement is managed by a joint board including the three partners. The basic objective of this program is to develop a method which integrates, or makes it possible to integrate at a later stage, the greatest number of significant parameters. Also, in order to prepare the practical applications, a special effort is being made to collect the data corresponding to these parameters. Parallel basic research program have been launched in order to clarify our knowledge on some important parts of the main factors contributing to the evaluation. The results of this research will be progressively introduced into the method or will help checking its validity

  20. Signs in neuroradiology - part 1

    Energy Technology Data Exchange (ETDEWEB)

    Goncalves, Fabricio Guimaraes, E-mail: goncalves.neuroradio@gmail.co [McGill University Health Centre (MUHC), Montreal, Quebec (Canada). Montreal General Hospital; Barra, Filipe Ramos; Jovem, Cassio Lemos [Hospital Universitario de Brasilia, DF (Brazil). Dept. of Radiology and Imaging Diagnosis; Matos, Valter de Lima [Hospital Santa Luzia, Brasilia, DF (Brazil); Amaral, Lazaro Luis Faria do [MedImagem - Hospital da Beneficencia Portuguesa de Sao Paulo, SP (Brazil). Dept. of Neuroradiology; Carpio-O' Donovan, Raquel del [McGill University Health Centre (MUHC), Montreal, Quebec (Canada)

    2011-03-15

    The use of signs or analogies for interpretation and description of medical images is an old and common practice among radiologists. Comparison of findings with animals, food or objects is not unprecedented and routinely performed. Many signs are quite specific and, in some cases, pathognomonic. Indeed, notwithstanding their degree of specificity, signs may help in the characterization of certain diseases. Several neuroradiological signs have been already described. The authors will present 15 neuroradiology signs in the present essay, approaching their main characteristics, the significance of their role in the clinical practice, as well as their respective imaging findings. (author)

  1. Signs in neuroradiology - part 1

    International Nuclear Information System (INIS)

    Goncalves, Fabricio Guimaraes; Amaral, Lazaro Luis Faria do

    2011-01-01

    The use of signs or analogies for interpretation and description of medical images is an old and common practice among radiologists. Comparison of findings with animals, food or objects is not unprecedented and routinely performed. Many signs are quite specific and, in some cases, pathognomonic. Indeed, notwithstanding their degree of specificity, signs may help in the characterization of certain diseases. Several neuroradiological signs have been already described. The authors will present 15 neuroradiology signs in the present essay, approaching their main characteristics, the significance of their role in the clinical practice, as well as their respective imaging findings. (author)

  2. Emission of pesticides during drilling and deposition in adjacent areas

    Directory of Open Access Journals (Sweden)

    Heimbach, Udo

    2014-02-01

    Full Text Available In seven experiments seeds of maize, oil seed rape and barley, treated with neonicotinoids, were sown using pneumatic drilling equipment with deflectors attached in case of pneumatic suction systems. Directly adjacent to the drilled area of usually about 50 m width were replicated areas with bare soil as well as with crops. During maize (Zea mays drilling flowering oil seed rape (Brassica napus and during drilling of barley (Hordeum vulgare and oil seed rape flowering white mustard (Sinapis alba was adjacent. The amount of residues in the adjacent non crop areas in Petri dishes being distributed on the bare soil declined only slowly from 1 to 20 m distance from the area drilled. Seed batches with more abrasion and higher content of active substances in the dust resulted in higher residues off crop. After drilling of maize in four experiments in Petri dishes in adjacent non crop areas in 1-5 m distance between 0.02 and 0.40 g a.s./ha of neonicotinoids and in the adjacent oil seed rape a total of 0.05–0.80 g a.s./ha were detected. After drilling oil seed rape or barley these values were only 0.02–0.06 g a.s./ha in Petri dishes in non crop areas and 0.03-0.08 g a.s./ha in total in adjacent white mustard. In gauze net samplers installed vertically in 3 m distance in non crop areas up to seven times higher values were detected compared to Petri dishes.

  3. Americium behaviour in plastic vessels

    Energy Technology Data Exchange (ETDEWEB)

    Legarda, F.; Herranz, M. [Departamento de Ingenieria Nuclear y Mecanica de Fluidos, Escuela Tecnica Superior de Ingenieria de Bilbao, Universidad del Pais Vasco (UPV/EHU), Alameda de Urquijo s/n, 48013 Bilbao (Spain); Idoeta, R., E-mail: raquel.idoeta@ehu.e [Departamento de Ingenieria Nuclear y Mecanica de Fluidos, Escuela Tecnica Superior de Ingenieria de Bilbao, Universidad del Pais Vasco (UPV/EHU), Alameda de Urquijo s/n, 48013 Bilbao (Spain); Abelairas, A. [Departamento de Ingenieria Nuclear y Mecanica de Fluidos, Escuela Tecnica Superior de Ingenieria de Bilbao, Universidad del Pais Vasco (UPV/EHU), Alameda de Urquijo s/n, 48013 Bilbao (Spain)

    2010-07-15

    The adsorption of {sup 241}Am dissolved in water in different plastic storage vessels was determined. Three different plastics were investigated with natural and distilled waters and the retention of {sup 241}Am by these plastics was studied. The same was done by varying vessel agitation time, vessel agitation speed, surface/volume ratio of water in the vessels and water pH. Adsorptions were measured to be between 0% and 70%. The adsorption of {sup 241}Am is minimized with no water agitation, with PET or PVC plastics, and by water acidification.

  4. Americium behaviour in plastic vessels

    International Nuclear Information System (INIS)

    Legarda, F.; Herranz, M.; Idoeta, R.; Abelairas, A.

    2010-01-01

    The adsorption of 241 Am dissolved in water in different plastic storage vessels was determined. Three different plastics were investigated with natural and distilled waters and the retention of 241 Am by these plastics was studied. The same was done by varying vessel agitation time, vessel agitation speed, surface/volume ratio of water in the vessels and water pH. Adsorptions were measured to be between 0% and 70%. The adsorption of 241 Am is minimized with no water agitation, with PET or PVC plastics, and by water acidification.

  5. PWR vessel flaw distribution development

    International Nuclear Information System (INIS)

    Rosinski, S.T.; Kennedy, E.L.; Foulds, J.R.; Kinsman, K.M.

    1990-01-01

    This paper reports on PWR pressure vessels which operate under NRC rules and regulatory guides intended to prevent failure of the vessels. Plants failing to meet the operating criteria specified under these rules and regulations are required to analytically demonstrate fitness for service in order to continue operation. The initial flaw size or distribution of initial vessel flaws is a key input to the required vessel integrity analyses. However, the flaw distribution assumed in the development of the NRC Regulations and recommended for the plant specific analyses is potentially over-conservative. This is because the distribution is based on the limited amount of vessel inspection data available at the time the criteria were being developed and does not take full advantage of the more recent and reliable domestic vessel inspection results. The U.S. Department of Energy is funding an effort through Sandia National Laboratories to investigate the possibility of developing a new flaw distribution based on the increased amount and improved reliability of domestic vessel inspection data. Results of Phase I of the program indicate that state-of-the-art NDE systems' capabilities are sufficient for development of a new flaw distribution that could ultimately provide life extension benefits over the presently required operating practice

  6. Test of 6-in.-thick pressure vessels. Series 3: intermediate test vessel V-7

    International Nuclear Information System (INIS)

    Merkle, J.G.; Robinson, G.C.; Holz, P.P.; Smith, J.E.; Bryan, R.H.

    1976-08-01

    The test of intermediate test vessel V-7 was a crack-initiation fracture test of a 152-mm-thick (6-in.), 990-mm-OD (39-in.) vessel of ASTM A533, grade B, class 1 steel plate with a sharp outside surface flaw 457 mm (18 in.) long and about 135 mm (5.3 in.) deep. The vessel was heated to 91 0 C (196 0 F) and pressurized hydraulically until leakage through the flaw terminated the test at a peak pressure of 147 MPa (21,350 psi). Fracture toughness data obtained by testing precracked Charpy-V and compact-tension specimens machined from a prolongation of the cylindrical test shell were used in pretest analyses of the flawed vessel. The vessel, as expected, did not burst. Upon depressurization, the ruptured ligament closed so as to maintain static pressure without leakage at about 129 MPa

  7. Hydrogen storage in insulated pressure vessels

    Energy Technology Data Exchange (ETDEWEB)

    Aceves, S.M.; Garcia-Villazana, O. [Lawrence Livermore National Lab., CA (United States)

    1998-08-01

    Insulated pressure vessels are cryogenic-capable pressure vessels that can be fueled with liquid hydrogen (LH{sub 2}) or ambient-temperature compressed hydrogen (CH{sub 2}). Insulated pressure vessels offer the advantages of liquid hydrogen tanks (low weight and volume), with reduced disadvantages (lower energy requirement for hydrogen liquefaction and reduced evaporative losses). This paper shows an evaluation of the applicability of the insulated pressure vessels for light-duty vehicles. The paper shows an evaluation of evaporative losses and insulation requirements and a description of the current analysis and experimental plans for testing insulated pressure vessels. The results show significant advantages to the use of insulated pressure vessels for light-duty vehicles.

  8. Earthquake-proof supporting structure in reactor vessel

    International Nuclear Information System (INIS)

    Sakurai, Akio; Sekine, Katsuhisa; Madokoro, Manabu; Katoono, Shin-ichi; Konno, Mutsuo; Suzuki, Takuro.

    1990-01-01

    Conventional earthquake-proof structure comprises a vessel vibration stopper integrated to a reactor vessel, powder for restricting the horizontal displacements, a safety vessel surrounds the outer periphery of the reactor vessel and a safety vessel vibration stopper integrated therewith, which are fixed to buildings. However, there was a problem that a great amount of stresses are generated in the base of the reactor vessel vibration stopper due to reaction of the powders which restrict thermal expansion. In order to remarkably reduce the reaction of the powers, powders are charged into a spaces formed between each of the reactor vessel vibration stopper, the safety vessel vibration stopper and the flexible member disposed between them. According to this constitution, the reactor vessel vibration stopper does not undergo a great reaction of the powers upon thermal expansion of the reactor vessel to moderate the generated stresses, maintain the strength and provide earthquake-proof supporting function. (N.H.)

  9. Diffusion-Weighted MRI Assessment of Adjacent Disc Degeneration After Thoracolumbar Vertebral Fractures

    Energy Technology Data Exchange (ETDEWEB)

    Noriega, David C., E-mail: dcnoriega1970@gmail.com [Valladolid University Hospital, Spine Department (Spain); Marcia, Stefano, E-mail: stemarcia@gmail.com [SS. Trinità Hospital ASL 8 Cagliari, Department of Radiology (Italy); Ardura, Francisco, E-mail: fardura@ono.com [Valladolid University Hospital, Spine Department (Spain); Lite, Israel Sanchez, E-mail: israelslite@hotmail.com [Valladolid University Hospital, Radiology Department (Spain); Marras, Mariangela, E-mail: mariangela.marrasmd@gmail.com [Azienda Ospedaliero Brotzu (A.O.B.), Department of Radiology (Italy); Saba, Luca, E-mail: lucasaba@tiscali.it [Azienda Ospedaliero Universitaria (A.O.U.), Department of Radiology (Italy)

    2016-09-15

    ObjectiveThe purpose of this study was to assess, by the mean apparent diffusion coefficient (ADC), if a relationship exists between disc ADC and MR findings of adjacent disc degeneration after thoracolumbar fractures treated by anatomic reduction using vertebral augmentation (VAP).Materials and MethodsTwenty non-consecutive patients (mean age 50.7 years; range 45–56) treated because of vertebral fractures, were included in this study. There were 10 A3.1 and 10 A1.2 fractures (AO classification). Surgical treatment using VAP was applied in 14 cases, and conservative in 6 patients. MRI T2-weighted images and mapping of apparent diffusion coefficient (ADC) of the intervertebral disc adjacent to the fractured segment were performed after a mean follow-up of 32 months. A total of 60 discs, 3 per patient, were analysed: infra-adjacent, supra-adjacent and a control disc one level above the supra-adjacent.ResultsNo differences between patients surgically treated and those following a conservative protocol regarding the average ADC values obtained in the 20 control discs analysed were found. Considering all discs, average ADC in the supra-adjacent level was lower than in the infra-adjacent (1.35 ± 0.12 vs. 1.53 ± 0.06; p < 0.001). Average ADC values of the discs used as a control were similar to those of the infra-adjacent level (1.54 ± 0.06). Compared to surgically treated patients, discs at the supra-adjacent fracture level showed statistically significant lower values in cases treated conservatively (p < 0.001). The variation in the delay of surgery had no influence on the average values of ADC at any of the measured levels.ConclusionsADC measurements of the supra-adjacent discs after a mean follow-up of 32 months following thoracolumbar fractures, showed that restoration of the vertebral collapse by minimally invasive VAP prevents posttraumatic disc degeneration.

  10. Pressure vessel for nuclear reactors

    International Nuclear Information System (INIS)

    1975-01-01

    The invention applies to a pressure vessel for nuclear reactors whose shell, made of cast metal segments, has a steel liner. This liner must be constructed to withstand all operational stresses and to be easily repairable. The invention solves this problem by installing the liner at a certain distance from the inner wall of the pressure vessel shell and by filling this clearance with supporting concrete. Both the concrete and the steel liner must have a lower prestress than the pressure vessel shell. In order to avoid damage to the liner when prestressing the pressure vessel shell, special connecting elements are provided which consist of welded-on fastening elements projecting into recesses in the cast metal segments of the pressure vessel. Their design is described in detail. (TK) [de

  11. Safety vessels for explosive fusion reactor

    International Nuclear Information System (INIS)

    Mineev, V.

    1994-01-01

    The failure of several types of geometrically similar cylindrical and spherical steel and glass fibers vessels filled with water or air was investigated when an explosive charge of TNT was detonated in the center. Vessels had radius 50-1000 mm, thickness of walls 2-20%. The detonation on TNT imitated energy release. The parameter: K = M/mf is a measure of the strength of the vessel where M is the mass of the vessel, and mf is the mass of TNT for which the vessel fails. This demanded 2-4 destroyed and nondestroyed shots. It may be showed that: K=A/σ f where σ f is the fracture stress of the material vessel, and A = const = F(energy TNT, characteristic of elasticity of vessel material). The chief results are the following: (1) A similar increase in the geometrical dimensions of steel vessels by a factor of 10 leads to the increase of parameter K in about 5 times and to decrease of failure deformation in 7 times (scale effect). (2) For glass fibers, scale effect is absent. (3) This problem is solved in terms of theory energetic scale effect. (4) The concept of TNT equivalent explosive makes it possible to use these investigations to evaluate the response of safety vessels for explosive fusion reactor

  12. Radioactive waste processing vessel

    International Nuclear Information System (INIS)

    Hayashi, Masaru; Suzuki, Osamu; Ishizaki, Kanjiro.

    1987-01-01

    Purpose: To obtain a vessel of a reduced weight and with no external leaching of radioactive materials. Constitution: The vessel main body is constituted, for example, with light weight concretes or foamed concretes, particularly, foamed concretes containing fine closed bubbles in the inside. Then, layers having dense texture made of synthetic resin such as polystylene, vinylchloride resin, etc. or metal plate such as stainless plate are integrally disposed to the inner surface of the vessel main body. The cover member also has the same structure. (Sekiya, K.)

  13. Ionizing radiations and blood vessels

    International Nuclear Information System (INIS)

    Vorob'ev, E.I.; Stepanov, R.P.

    1985-01-01

    Data on phenomenology of radiation-induced changes in blood vessels are systematized and authors' experience is generalized. Modern concepts about processes leading to vessel structure injury after irradiation is critically analyzed. Special attention is paid to reparation and compensation of X-ray vessel injury, consideration of which is not yet sufficiently elucidated in literature

  14. Clinical results of single-vessel versus multiple-vessel infrapopliteal intervention

    OpenAIRE

    Darling, Jeremy; McCallum, John C.; Soden, Peter A.; Hon, J.J. (John J.); Guzman, R.J. (Raul J.); Wyers, M.C. (Mark C.); Verhagen, Hence; Schermerhorn, Marc

    2016-01-01

    textabstractObjective The effects of concomitant endovascular interventions on multiple infrapopliteal vessels are not well known, and the short-term and long-term sequelae of such procedures have not been reported. Methods From 2004 to 2014, 673 limbs in 528 patients underwent an infrapopliteal endovascular intervention for tissue loss (77%), rest pain (13%), stenosis of a previously treated vessel (5%), acute limb ischemia (3%), or claudication (2%). Outcomes included wound healing, RAS eve...

  15. Molten material-containing vessel

    International Nuclear Information System (INIS)

    Akagawa, Katsuhiko

    1998-01-01

    The molten material-containing vessel of the present invention comprises a vessel main body having an entrance opened at the upper end, a lid for closing the entrance, an outer tube having an upper end disposed at the lower surface of the lid, extended downwardly and having an closed lower end and an inner tube disposed coaxially with the outer tube. When a molten material is charged from the entrance to the inside of the vessel main body of the molten material-containing vessel and the entrance is closed by the lid, the outer tube and the inner tube are buried in the molten material in the vessel main body, accordingly, a fluid having its temperature elevated by absorption of the heat of the molten material rises along the inner circumferential surface of the outer tube, abuts against the lower surface of the lid and cooled by exchanging heat with the lid and forms a circulating flow. Since the heat in the molten material is continuously absorbed by the fluid, transferred to the lid and released from the lid to the atmospheric air, heat releasing efficiency can be improved compared with conventional cases. (N.H.)

  16. Americium behaviour in plastic vessels.

    Science.gov (United States)

    Legarda, F; Herranz, M; Idoeta, R; Abelairas, A

    2010-01-01

    The adsorption of (241)Am dissolved in water in different plastic storage vessels was determined. Three different plastics were investigated with natural and distilled waters and the retention of (241)Am by these plastics was studied. The same was done by varying vessel agitation time, vessel agitation speed, surface/volume ratio of water in the vessels and water pH. Adsorptions were measured to be between 0% and 70%. The adsorption of (241)Am is minimized with no water agitation, with PET or PVC plastics, and by water acidification. Copyright 2009 Elsevier Ltd. All rights reserved.

  17. Vessel Sampling and Blood Flow Velocity Distribution With Vessel Diameter for Characterizing the Human Bulbar Conjunctival Microvasculature.

    Science.gov (United States)

    Wang, Liang; Yuan, Jin; Jiang, Hong; Yan, Wentao; Cintrón-Colón, Hector R; Perez, Victor L; DeBuc, Delia C; Feuer, William J; Wang, Jianhua

    2016-03-01

    This study determined (1) how many vessels (i.e., the vessel sampling) are needed to reliably characterize the bulbar conjunctival microvasculature and (2) if characteristic information can be obtained from the distribution histogram of the blood flow velocity and vessel diameter. Functional slitlamp biomicroscope was used to image hundreds of venules per subject. The bulbar conjunctiva in five healthy human subjects was imaged on six different locations in the temporal bulbar conjunctiva. The histograms of the diameter and velocity were plotted to examine whether the distribution was normal. Standard errors were calculated from the standard deviation and vessel sample size. The ratio of the standard error of the mean over the population mean was used to determine the sample size cutoff. The velocity was plotted as a function of the vessel diameter to display the distribution of the diameter and velocity. The results showed that the sampling size was approximately 15 vessels, which generated a standard error equivalent to 15% of the population mean from the total vessel population. The distributions of the diameter and velocity were not only unimodal, but also somewhat positively skewed and not normal. The blood flow velocity was related to the vessel diameter (r=0.23, Psampling size of the vessels and the distribution histogram of the blood flow velocity and vessel diameter, which may lead to a better understanding of the human microvascular system of the bulbar conjunctiva.

  18. Radiation embrittlement of PWR vessel supports

    International Nuclear Information System (INIS)

    Cheverton, R.D.; Robinson, G.C.; Pennell, W.E.; Nanstad, R.K.

    1989-01-01

    Several studies pertaining to radiation damage of PWR vessel supports were conducted between 1978 and 1987. During this period, apparently there was no reason to believe that low-temperature (<100 degree C) MTR embrittlement data were not appropriate for evaluating embrittlement of PWR vessel supports. However, late in 1986, data from the High Flux Isotope Reactor (HFIR) vessel surveillance program indicated that the embrittlement rates of the several HFIR vessel materials (A212-B, A350-LF3, A105-II) were substantially greater than anticipated on the basis of MTR data. Further evaluation of the HFIR data suggested that a fluence-rate effect was responsible for the apparent discrepancy, and shortly thereafter it became apparent that this rate effect was applicable to the evaluation of LWR vessel supports. As a result, the Nuclear Regulatory Commission (NRC) requested that the Oak Ridge National Laboratory (ORNL) evaluate the impact of the apparent embrittlement rate effect on the integrity of light-water-reactor (LWR) vessel supports. The purpose of the study was to provide an indication of whether the integrity of reactor vessel supports is likely to be challenged by radiation-induced embrittlement. The scope of the evaluation included correlation of the HFIR data for application to the evaluation of LWR vessel supports; a survey and cursory evaluation of all US LWR vessel support designs, selection of two plants for specific-plant evaluation, and a specific-plant evaluation of both plants to determine critical flaw sizes for their vessel supports. 19 refs., 8 figs., 2 tabs

  19. Prestressed cast iron pressure vessels as burst-proof pressure vessels for innovative nuclear applications

    International Nuclear Information System (INIS)

    Froehling, W.; Boettcher, A.; Bounin, D.; Steinwarz, W.; Geiss, M.; Trauth, M.

    2000-01-01

    The amendment to the German Atomic Energy Act from July 28, 1994 requires that events 'whose occurrence is practically excluded by the measures against damages', i.e. events of the category residual risk, must not necessitate far reaching protective measures outside the plant. For a conventional reactor pressure vessel, the residual risk consists in the very small probability of a catastrophic failure (formation of a large fracture opening, bursting of the vessel). With a prestressed cast iron vessel (PCIV), the formation of a large fracture opening or bursting of the vessel, respectively, is impossible due to its design properties. Against this background the possibility of the use of this type of pressure vessel for lightwater reactors has been studied in the frame of a 'Working Group for Innovative Nuclear Technology', founded by different research institutes and industrial companies. Furthermore, it has been studied whether the use of the PCIV support the realization of a corecatcher system. The results are presented in this report. Already many years earlier, Siempelkamp has performed industrial development and Forschungszentrum Juelich related experimental and theoretical safety research for the PCIV as an innovative, bust-proof pressure vessel concept. This development of the PCIV as well as its safety properties are also presented in a conclusive manner. (orig.) [de

  20. Modeling online social signed networks

    Science.gov (United States)

    Li, Le; Gu, Ke; Zeng, An; Fan, Ying; Di, Zengru

    2018-04-01

    People's online rating behavior can be modeled by user-object bipartite networks directly. However, few works have been devoted to reveal the hidden relations between users, especially from the perspective of signed networks. We analyze the signed monopartite networks projected by the signed user-object bipartite networks, finding that the networks are highly clustered with obvious community structure. Interestingly, the positive clustering coefficient is remarkably higher than the negative clustering coefficient. Then, a Signed Growing Network model (SGN) based on local preferential attachment is proposed to generate a user's signed network that has community structure and high positive clustering coefficient. Other structural properties of the modeled networks are also found to be similar to the empirical networks.

  1. Sign language: an international handbook

    NARCIS (Netherlands)

    Pfau, R.; Steinbach, M.; Woll, B.

    2012-01-01

    Sign language linguists show here that all the questions relevant to the linguistic investigation of spoken languages can be asked about sign languages. Conversely, questions that sign language linguists consider - even if spoken language researchers have not asked them yet - should also be asked of

  2. 46 CFR 4.03-40 - Public vessels.

    Science.gov (United States)

    2010-10-01

    ... INVESTIGATIONS Definitions § 4.03-40 Public vessels. Public vessel means a vessel that— (a) Is owned, or demise... Department (except a vessel operated by the Coast Guard or Saint Lawrence Seaway Development Corporation...

  3. Association between parafunctional habit and sign and symptoms of temporomandibular dysfunction

    Directory of Open Access Journals (Sweden)

    Harshali Fale

    2018-01-01

    Full Text Available Introduction: Temporomandibular disorder (TMD is a group of condition affecting the temporomandibular joint, masticatory muscles, and the adjacent structures. The etiology of TMD in children and adolescents is considered multifactorial in nature and has been related to trauma, malocclusion, and parafunctional habits. Aim: The aim of this study is to find whether harmful oral habits are associated with sign and symptoms of TMD among adolescents in Wardha district. Materials and Methods: A short-span study was conducted in Wardha, Maharashtra. A self-administered based study was done among 200 adolescents which comprised of 107 females and 93 males. Data were collected using self-administered questionnaire and clinical oral examination that was conducted. The questionnaire was consist of knowledge responses (yes/no and attitude responses (never, rarely, sometimes, often, and always. Chi-square test was used to perform statistical analysis and level of significance was set at P < 0.05. Results: The main method used was self-administered questionnaires with sample characteristics of 53.5% female and 46.5% male. Population was divided into two age groups. Total number of adolescents in age Group 1 (9–14 years was 85 and age Group 2 (15–19 years was 115. Seventy-seven (38.5% adolescent reported no sign and symptoms of TMD and rest of them reported yes to at least one statement of questionnaire. Bruxism (67% was the most frequently observed habit whereas chewing gums (5% as the least observed habit. Statistically significant gender difference was not observed in the questionnaire. Higher frequency of TMD symptoms was reported in the age group of 15–19 years. Sixteen (8% subjects reported nonparafunctional habits whereas 184 (92% subjects had parafunctional habits. During clinical examination, muscle sensitivity to palpation was most frequent sign in the age of group 15–19 years with P = 0.023. Higher severity was reported are morning facial

  4. Prosopomorphic vessels from Moesia Superior

    Directory of Open Access Journals (Sweden)

    Nikolić Snežana

    2008-01-01

    Full Text Available The prosopomorphic vessels from Moesia Superior had the form of beakers varying in outline but similar in size. They were wheel-thrown, mould-made or manufactured by using a combination of wheel-throwing and mould-made appliqués. Given that face vessels are considerably scarcer than other kinds of pottery, more than fifty finds from Moesia Superior make an enviable collection. In this and other provinces face vessels have been recovered from military camps, civilian settlements and necropolises, which suggests that they served more than one purpose. It is generally accepted that the faces-masks gave a protective role to the vessels, be it to protect the deceased or the family, their house and possessions. More than forty of all known finds from Moesia Superior come from Viminacium, a half of that number from necropolises. Although tangible evidence is lacking, there must have been several local workshops producing face vessels. The number and technological characteristics of the discovered vessels suggest that one of the workshops is likely to have been at Viminacium, an important pottery-making centre in the second and third centuries.

  5. Nuclear reactor pressure vessel flaw distribution development

    International Nuclear Information System (INIS)

    Kennedy, E.L.; Foulds, J.R.; Basin, S.L.

    1991-12-01

    Previous attempts to develop flaw distributions for probabilistic fracture mechanics analyses of pressurized water reactor (PWR) vessels have aimed at the estimation of a ''generic'' distribution applicable to all PWR vessels. In contrast, this report describes (1) a new flaw distribution development analytic methodology that can be applied to the analysis of vessel-specific inservice inspection (ISI) data, and (2) results of the application of the methodology to the analysis of flaw data for each vessel case (ISI data on three PWR vessels and laboratory inspection data on sections of the Midland reactor vessel). Results of this study show significant variation among the flaw distributions derived from the various data sets analyzed, strongly suggesting than a vessel-specific flaw distribution (for vessel integrity prediction under pressurized thermal shock) is preferred over a ''generic'' distribution. In addition, quantitative inspection system flaw sizing accuracy requirements have been identified for developing a flaw distribution from vessel ISI data. The new flaw data analysis methodology also permits quantifying the reliability of the flaw distribution estimate. Included in the report are identified needs for further development of several aspects of ISI data acquisition and vessel integrity prediction practice

  6. Traffic sign detection and analysis

    DEFF Research Database (Denmark)

    Møgelmose, Andreas; Trivedi, Mohan M.; Moeslund, Thomas B.

    2012-01-01

    Traffic sign recognition (TSR) is a research field that has seen much activity in the recent decade. This paper introduces the problem and presents 4 recent papers on traffic sign detection and 4 recent papers on traffic sign classification. It attempts to extract recent trends in the field...

  7. Targeting Therapy Resistant Tumor Vessels

    Science.gov (United States)

    2008-08-01

    Morris LS. Hysterectomy vs. resectoscopic endometrial ablation for the control of abnormal uterine bleeding . A cost-comparative study. J Reprod Med 1994;39...after the antibody treatment contain a pericyte coat, vessel architecture is normal, the diameter of the vessels is smaller (dilated, abnormal vessels...involvement of proteases from inflammatory mast cells and functionally abnormal (Carmeliet and Jain, 2000; Pasqualini (Coussens et al., 1999) and other bone

  8. The Forbidden Signs

    DEFF Research Database (Denmark)

    Kilstrup, Mogens

    2016-01-01

    While the field of semiotics has been active since it was started by Peirce, it appears like the last decade has been especially productive with a number of important new concepts being developed within the biosemiotics community. The novel concept of the Semiotic scaffold by Hoffmeyer is an impo......While the field of semiotics has been active since it was started by Peirce, it appears like the last decade has been especially productive with a number of important new concepts being developed within the biosemiotics community. The novel concept of the Semiotic scaffold by Hoffmeyer...... is an important addition that offers insight into the hardware requirements for bio-semiosis. As any type of semiosis must be dependent upon Semiotic scaffolds, I recently argued that the process of semiosis has to be divided into two separate processes of sign establishment and sign interpretation....... I also show that biological semiosis offers examples of forbidden signs, where the faulty interpretation of signs may lead to decimation of whole evolutionary lines of organisms. A new concept of Evolutionary memory which is applicable to both human and biological semiosis is explained...

  9. Pressurized wet digestion in open vessels (T11)

    International Nuclear Information System (INIS)

    Kettisch, P.; Maichin, P.; Zischka, M.; Knapp, G.

    2002-01-01

    Full text: Pressurized wet digestion in closed vessels, microwave assisted or with conventional conductive heating, is the most important sample preparation technique for digestion or leaching procedures in element analysis. In comparison to open vessel digestion closed vessel digestion methods have many advantages, but there is one disadvantage - complex and expensive vessel designs. A new technique - pressurized wet digestion in open vessels - combine the advantages of closed vessel sample digestion with the application of simple and cheap open vessels made of quartz or PFA. The vessels are placed in a high pressure Asher HPA, which is adapted with a Teflon liner and filled partly with water. The analytical results with 30 ml quartz vessels, 22 ml PFA vessels and 1.5 ml PIA auto sampler cups will be shown. In principle every dimensions of vessels can be used. The vessels are loaded with sample material (max. 1.5 g with quartz vessels, max. 0.5 g with PFA vessels and 50 mg with auto sampler cups) and digestion reagent. Afterwards the vessels are simply covered with PTFE stoppers and not sealed. The vessels are transferred into a special adapted HPA and digested at temperatures up to 270 o C. The digestion time is 90 min. and cooling down to room temperature 30 min. The analytical results of CRM's are within the certified values and no cross contamination and losses of volatile elements could be observed. (author)

  10. Early Verb Constructions in French: Adjacency on the Left Edge

    Science.gov (United States)

    Veneziano, Edy; Clark, Eve V.

    2016-01-01

    Children acquiring French elaborate their early verb constructions by adding adjacent morphemes incrementally at the left edge of core verbs. This hypothesis was tested with 2657 verb uses from four children between 1;3 and 2;7. Consistent with the Adjacency Hypothesis, children added clitic subjects frst only to present tense forms (as in…

  11. Flaw distribution development from vessel ISI data

    International Nuclear Information System (INIS)

    Foulds, J.R.; Kennedy, E.L.; Basin, S.L.; Rosinski, S.T.

    1991-01-01

    Previous attempts to develop flaw distributions for use in the structural integrity evaluation of pressurized water reactor (PWR) vessels have aimed at the estimation of a ''generic'' distribution applicable to all vessels. In contrast, this paper describes the analysis of vessel-specific in-service inspection (ISI) data for the development of a flaw distribution reliably representative of the condition of the particular vessel inspected. The application of the methodology may be extended to other vessels, but has been primarily developed for PWR reactor vessels. For this study, the flaw data analyzed included data obtained from three recently performed PWR vessel ISIs and from laboratory inspection of selected weldment sections of the Midland reactor vessel. The variability in both the character of the reviewed data (size range of flaws, number of flaws) and the UT (ultrasonic test) inspection system performance identified a need for analyzing the inspection results on a vessel-, or data set-specific basis. For this purpose, traditional histogram-based methods were inadequate, and a new methodology that can accept a very small number of flaws (typical of vessel-specific ISI results) and that includes consideration of inspection system flaw detection reliability, flaw sizing accuracy and flaw detection threshold, was developed. Results of the application of the methodology to each of the four PWR reactor vessel cases studied are presented and discussed

  12. Did antepartum hypoxic insult caused by fetal vessel thrombosis influence the procalcitonin level in umbilical blood? A case report.

    Science.gov (United States)

    Kaneko, Masatoki; Yamauchi, Aya; Yamashita, Rie; Sato, Yuichiro; Kodama, Yuki; Sameshima, Hiroshi

    2015-11-01

    We report a case of marked elevation of the procalcitonin level in umbilical blood and neonatal blood at birth. The mother did not perceive fetal motion. Antepartum fetal heart rate monitoring showed a loss of variability and absence of acceleration. No fetal breathing movement, fetal movement, or fetal tone were observed by ultrasonography. The female neonate was delivered by cesarean section at 25 weeks of gestation, with birthweight 774 g. The umbilical arterial pH value at birth was 7.29. Mild elevation in interleukin-6 and tumor necrosis factor-α in umbilical blood were observed. Cytochrome c showed a high level in umbilical and neonatal blood at birth. Placental histopathology revealed multiple fetal vessel thrombosis in the large stem villi and chorionic vessels. The neonate showed no infectious signs throughout the neonatal period. Computed tomography at 3 months of age revealed atrophy in the cerebrum and cerebellum. At 1 year after birth, the infant showed spastic quadriplegia. In this case, antepartum asphyxia due to fetal vessel thrombosis may have influenced the elevation of procalcitonin level in umbilical blood and neonatal blood at birth. © 2015 Japan Society of Obstetrics and Gynecology.

  13. Trapping of Embolic Particles in a Vessel Phantom by Cavitation-Enhanced Acoustic Streaming

    Science.gov (United States)

    Maxwell, Adam D.; Park, Simone; Vaughan, Benjamin L.; Cain, Charles A.; Grotberg, James B.; Xu, Zhen

    2014-01-01

    Cavitation clouds generated by short, high-amplitude, focused ultrasound pulses were previously observed to attract, trap, and erode thrombus fragments in a vessel phantom. This phenomenon may offer a noninvasive method to capture and eliminate embolic fragments flowing through the bloodstream during a cardiovascular intervention. In this article, the mechanism of embolus trapping was explored by particle image velocimetry (PIV). PIV was used to examine the fluid streaming patterns generated by ultrasound in a vessel phantom with and without crossflow of blood-mimicking fluid. Cavitation enhanced streaming, which generated fluid vortices adjacent to the focus. The focal streaming velocity, uf, was as high as 120 cm/s, while mean crossflow velocities, uc, were imposed up to 14 cm/s. When a solid particle 3-4 mm diameter was introduced into crossflow, it was trapped near the focus. Increasing uf promoted particle trapping while increasing uc promoted particle escape. The maximum crossflow Reynolds number at which particles could be trapped, Rec, was approximately linear with focal streaming number, Ref, i.e. Rec = 0.25Ref + 67.44 (R2=0.76) corresponding to dimensional velocities uc=0.084uf + 3.122 for 20 < uf < 120 cm/s. The fluidic pressure map was estimated from PIV and indicated a negative pressure gradient towards the focus, trapping the embolus near this location. PMID:25109407

  14. Proposal of Ex-Vessel dosimetry for pressure vessel Atucha II

    International Nuclear Information System (INIS)

    Chiaraviglio, N.; Bazzana, S.

    2013-01-01

    Nuclear reactor dosimetry has the purpose of guarantee that changes in material mechanical properties of critical materials do not compromise the reactor safety. In PWR in which the top of the reactor vessel is open once a year, is possible to use Charpy specimens to measure the change in mechanical properties. Atucha II nuclear power plant is a reactor with on-line refueling so there is no access to the inside of the pressure vessel. Because of this, ex-vessel dosimetry must be performed and mechanical properties changes must be inferred from radiation damage estimations. This damage can be calculated using displacement per atom cross sections and a transport code such as MCNP. To increase results reliability it is proposed to make a neutron spectrum unfolding using activation dosimeters irradiated during one operation cycle of the power plant. In this work we present a dosimetry proposal for such end, made in base of unfolding procedures and experimental background. (author) [es

  15. Numeral Incorporation in Japanese Sign Language

    Science.gov (United States)

    Ktejik, Mish

    2013-01-01

    This article explores the morphological process of numeral incorporation in Japanese Sign Language. Numeral incorporation is defined and the available research on numeral incorporation in signed language is discussed. The numeral signs in Japanese Sign Language are then introduced and followed by an explanation of the numeral morphemes which are…

  16. High Performance Marine Vessels

    CERN Document Server

    Yun, Liang

    2012-01-01

    High Performance Marine Vessels (HPMVs) range from the Fast Ferries to the latest high speed Navy Craft, including competition power boats and hydroplanes, hydrofoils, hovercraft, catamarans and other multi-hull craft. High Performance Marine Vessels covers the main concepts of HPMVs and discusses historical background, design features, services that have been successful and not so successful, and some sample data of the range of HPMVs to date. Included is a comparison of all HPMVs craft and the differences between them and descriptions of performance (hydrodynamics and aerodynamics). Readers will find a comprehensive overview of the design, development and building of HPMVs. In summary, this book: Focuses on technology at the aero-marine interface Covers the full range of high performance marine vessel concepts Explains the historical development of various HPMVs Discusses ferries, racing and pleasure craft, as well as utility and military missions High Performance Marine Vessels is an ideal book for student...

  17. Reactor-vessel-sectioning demonstration

    International Nuclear Information System (INIS)

    Lundgren, R.A.

    1981-07-01

    A successful technical demonstration of simulated reactor vessel sectioning was completed using the combined techniques of air arc gouging and flame cutting. A 4-ft x 3-ft x 9-in. thick sample was fabricated of A36 carbon steel to simulate a reactor vessel wall. A 1/4-in layer of stainless steel (SS) was tungsten inert gas (TIG)-welded to the carbon steel. Several techniques were considered to section the simulated reactor vessel: an air arc gouger was chosen to penetrate the stainless steel, and flame cutting was selected to sever the carbon steel. After the simulated vessel was successfully cut from the SS side, another cut was made, starting from the carbon steel side. This cut was also successful. Cutting from the carbon steel side has the advantages of cost reduction since the air arc gouging step is eliminated and contamination controlled because the molten metal is blown inward

  18. The vessel fluence; Fluence cuve

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    This book presents the proceedings of the technical meeting on the reactors vessels fluence. They are grouped in eight sessions: the industrial context and the stakes of the vessels control; the organization and the methodology for the fluence computation; the concerned physical properties; the reference computation methods; the fluence monitoring in an industrial context; vessels monitoring under irradiation; others methods in the world; the research and development programs. (A.L.B.)

  19. Objectifying the Adjacent and Opposite Angles: A Cultural Historical Analysis

    Science.gov (United States)

    Daher, Wajeeh; Musallam, Nadera

    2018-01-01

    The angle topic is central to the development of geometric knowledge. Two of the basic concepts associated with this topic are the adjacent and opposite angles. It is the goal of the present study to analyze, based on the cultural historical semiotics framework, how high-achieving seventh grade students objectify the adjacent and opposite angles'…

  20. 13 CFR 305.12 - Project sign.

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Project sign. 305.12 Section 305... WORKS AND ECONOMIC DEVELOPMENT INVESTMENTS Requirements for Approved Projects § 305.12 Project sign. The... the construction period of a sign or signs at a conspicuous place at the Project site indicating that...

  1. Expanded Fermilab pressure vessel directory program

    Energy Technology Data Exchange (ETDEWEB)

    Tanner, A.

    1983-01-01

    Several procedures have been written to manage the information pertaining to the vacuum tanks and pressure vessels for which the laboratory is responsible. These procedures have been named TANK1 for the vessels belonging to the Accelerator Division, TANK2 and TANK3 for the vessels belonging to the Research Division and to Technical Support respectively, and TANK4 for the vessels belonging to the Business Division. The operating procedures are otherwise identical in every respect.

  2. Expanded Fermilab pressure vessel directory program

    International Nuclear Information System (INIS)

    Tanner, A.

    1983-01-01

    Several procedures have been written to manage the information pertaining to the vacuum tanks and pressure vessels for which the laboratory is responsible. These procedures have been named TANK1 for the vessels belonging to the Accelerator Division, TANK2 and TANK3 for the vessels belonging to the Research Division and to Technical Support respectively, and TANK4 for the vessels belonging to the Business Division. The operating procedures are otherwise identical in every respect

  3. Effect of the in- and ex-vessel dual cooling on the retention of an internally heated melt pool in a hemispherical vessel

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, K.I.; Kim, B.S.; Kim, D.H. [Korea Atomic Energy Research Inst., Thermal Hydraulic Safety Research, Taejon (Korea, Republic of)

    2001-07-01

    A concept of in-vessel melt retention (IVMR) by in-vessel reflooding and/or reactor cavity flooding has been considered as one of severe accident management strategies and intensive researches to be performed worldwide. This paper provides some results of analytical investigations on the effect of both in- / ex-vessel cooling on the retention of an internally heated molten pool confined in a hemispherical vessel and the related thermal behavior of the vessel wall. For the present analysis, a scale-down reactor vessel for the KSNP reactor design of 1000 MWe (a large dry PWR) is utilized for a reactor vessel. Aluminum oxide melt simulant is also utilized for a real corium pool. An internal power density in the molten pool is determined by a simple scaling analysis that equates the heat flux on the the scale-down vessel wall to that estimated from KSNP. Well-known temperature-dependent boiling heat transfer curves are applied to the in- and ex-vessel cooling boundaries and radiative heat transfer has been only considered in the case of dry in-vessel. MELTPOOL, which is a computational fluid dynamics (CFD) code developed at KAERI, is applied to obtain the time-varying heat flux distribution from a molten pool and the vessel wall temperature distributions with angular positions along the vessel wall. In order to gain further insights on the effectiveness of in- and ex-vessel dual cooling on the in-vessel corium retention, four different boundary conditions has been considered: no water inside the vessel without ex-vessel cooling, water inside the vessel without ex-vessel cooling, no water inside the vessel with ex-vessel cooling, and water inside the vessel with ex-vessel cooling. (authors)

  4. Effect of the in- and ex-vessel dual cooling on the retention of an internally heated melt pool in a hemispherical vessel

    International Nuclear Information System (INIS)

    Ahn, K.I.; Kim, B.S.; Kim, D.H.

    2001-01-01

    A concept of in-vessel melt retention (IVMR) by in-vessel reflooding and/or reactor cavity flooding has been considered as one of severe accident management strategies and intensive researches to be performed worldwide. This paper provides some results of analytical investigations on the effect of both in- / ex-vessel cooling on the retention of an internally heated molten pool confined in a hemispherical vessel and the related thermal behavior of the vessel wall. For the present analysis, a scale-down reactor vessel for the KSNP reactor design of 1000 MWe (a large dry PWR) is utilized for a reactor vessel. Aluminum oxide melt simulant is also utilized for a real corium pool. An internal power density in the molten pool is determined by a simple scaling analysis that equates the heat flux on the the scale-down vessel wall to that estimated from KSNP. Well-known temperature-dependent boiling heat transfer curves are applied to the in- and ex-vessel cooling boundaries and radiative heat transfer has been only considered in the case of dry in-vessel. MELTPOOL, which is a computational fluid dynamics (CFD) code developed at KAERI, is applied to obtain the time-varying heat flux distribution from a molten pool and the vessel wall temperature distributions with angular positions along the vessel wall. In order to gain further insights on the effectiveness of in- and ex-vessel dual cooling on the in-vessel corium retention, four different boundary conditions has been considered: no water inside the vessel without ex-vessel cooling, water inside the vessel without ex-vessel cooling, no water inside the vessel with ex-vessel cooling, and water inside the vessel with ex-vessel cooling. (authors)

  5. Vacuum vessel for thermonuclear device

    International Nuclear Information System (INIS)

    Kikuchi, Mitsuru; Kurita, Gen-ichi; Onozuka, Masaki; Suzuki, Masaru.

    1997-01-01

    Heat of inner walls of a vacuum vessel that receive radiation heat from plasmas by way of first walls is removed by a cooling medium flowing in channels for cooling the inner walls. Nuclear heat generation of constitutional materials of the vacuum vessel caused by fast neutrons and γ rays is removed by a cooling medium flowing in cooling channels disposed in the vacuum vessel. Since the heat from plasmas and the nuclear heat generation are removed separately, the amount of the cooling medium flowing in the channels for cooling inner walls is increased for cooling a great amount of heat from plasmas while the amount of the cooling medium flowing in the channels for cooling the inside of the vacuum vessel is reduced for cooling the small amount of nuclear heat generation. Since the amount of the cooling medium can thus be optimized, the capacity of the facilities for circulating the cooling medium can be reduced. In addition, since the channels for cooling the inner walls and the channels of cooling medium formed in the vacuum vessel are disposed to the inner walls of the vacuum vessel on the side opposite to plasmas, integrity of the channels relative to leakage of the cooling medium can be ensured. (N.H.)

  6. Vacuum vessel for thermonuclear device

    Energy Technology Data Exchange (ETDEWEB)

    Kikuchi, Mitsuru; Kurita, Gen-ichi [Japan Atomic Energy Research Inst., Tokyo (Japan); Onozuka, Masaki; Suzuki, Masaru

    1997-07-31

    Heat of inner walls of a vacuum vessel that receive radiation heat from plasmas by way of first walls is removed by a cooling medium flowing in channels for cooling the inner walls. Nuclear heat generation of constitutional materials of the vacuum vessel caused by fast neutrons and {gamma} rays is removed by a cooling medium flowing in cooling channels disposed in the vacuum vessel. Since the heat from plasmas and the nuclear heat generation are removed separately, the amount of the cooling medium flowing in the channels for cooling inner walls is increased for cooling a great amount of heat from plasmas while the amount of the cooling medium flowing in the channels for cooling the inside of the vacuum vessel is reduced for cooling the small amount of nuclear heat generation. Since the amount of the cooling medium can thus be optimized, the capacity of the facilities for circulating the cooling medium can be reduced. In addition, since the channels for cooling the inner walls and the channels of cooling medium formed in the vacuum vessel are disposed to the inner walls of the vacuum vessel on the side opposite to plasmas, integrity of the channels relative to leakage of the cooling medium can be ensured. (N.H.)

  7. The Volpe Center GPS Adjacent Band Compatibility Program Plan : GPS Adjacent Band Compatibility Workshop, Volpe Center, Cambridge MA

    Science.gov (United States)

    2014-09-18

    Approach to DOT GPS Adjacent Band Compatibility Assessment. Identify forums and provide public outreach to make sure the progress and work are as open and transparent as possible. Develop an implementation plan that incorporates aspects from the DOT ...

  8. LARGE VESSEL INVOLVEMENT IN BEHCET’S DISEASE

    Directory of Open Access Journals (Sweden)

    AR. Jamshidi F. Davatchi

    2004-08-01

    Full Text Available Large vessel involvement is one of the hallmarks of Behcet’s disease (BD but its prevalence varies widely due to ethnic variation or environmental factors. The aim of this study is to find the characteristics of vasculo-Behcet (VB in Iran. In a cohort of 4769 patients with BD, those with vascular involvement were selected. Different manifestations of disease were compared with the remaining group of patients. A confidence interval at 95% (CI was calculated for each item. Vascular involvement was seen in 409 cases (8.6%; CI, 0.8. Venous involvement was seen in 396 cases, deep vein thrombosis in 294 (6.2%; CI, 0.7, superficial phlebitis in 108 (2.3%; CI, 0.4 and large vein thrombosis in 45 (0.9%; CI, 0.3. Arterial involvement was seen in 28 patients (25 aneurysms and 4 thromboses. Thirteen patients showed both arterial and venous involvement. The mean age of the patients with VB was slightly higher (P<0.03, but the disease duration was significantly longer (P<0.0003. VB was more common in men. As the presenting sign, ocular lesions were less frequent in VB (P<0.0006, while skin lesions were over 2 times more common in these cases (P<0.000001. VB was associated with a higher frequency of genital aphthosis, skin involvement, joint manifestations, epididymitis, CNS lesions and GI involvement. The juvenile form was less common in VB (P<0.03. High ESR was more frequent in VB (P=0.000002, but the frequency of false positive VDRL, pathergy phenomenon, HLA-B5 or HLA-B27 showed no significant difference between the two groups. In Iranian patients with BD, vascular involvement is not common and large vessel involvement is rare. It may be sex-related, and is more common in well-established disease with multiple organ involvement and longer disease duration.

  9. "Hearing" the signs:influence of sign language in an inclusive classroom

    OpenAIRE

    Monney, M. (Mariette)

    2017-01-01

    Abstract Finding new methods to achieve the goals of Education For All is a constant worry for primary school teachers. Multisensory methods have been proved to be efficient in the past decades. Sign Language, being a visual and kinesthetic language, could become a future educational tool to fulfill the needs of a growing diversity of learners. This ethnographic study describes how Sign Language exposure in inclusive classr...

  10. Kinship in Mongolian Sign Language

    Science.gov (United States)

    Geer, Leah

    2011-01-01

    Information and research on Mongolian Sign Language is scant. To date, only one dictionary is available in the United States (Badnaa and Boll 1995), and even that dictionary presents only a subset of the signs employed in Mongolia. The present study describes the kinship system used in Mongolian Sign Language (MSL) based on data elicited from…

  11. Tempest in a vessel

    International Nuclear Information System (INIS)

    Barre, Bertrand

    2015-01-01

    As the ASN made some statements about anomalies of carbon content in the EPR vessel bottom and top, the author recalls and comments some technical issues to better understand the information published on this topic. He notably addresses the role of the vessel, briefly indicates its operating conditions, shape and structure, and mechanical components for the top, its material and mechanical properties, and test samples used to assess mechanical properties. He also comments the phenomenon of radio-induced embrittlement, the vessel manufacturing process, and evokes the applicable regulations. He quotes and comments statements made by the ASN and Areva which evoke further assessments of the concerned components

  12. Eye Gaze in Creative Sign Language

    Science.gov (United States)

    Kaneko, Michiko; Mesch, Johanna

    2013-01-01

    This article discusses the role of eye gaze in creative sign language. Because eye gaze conveys various types of linguistic and poetic information, it is an intrinsic part of sign language linguistics in general and of creative signing in particular. We discuss various functions of eye gaze in poetic signing and propose a classification of gaze…

  13. Electronic traffic signs: Reflecting upon its transition

    Energy Technology Data Exchange (ETDEWEB)

    Arbaiza Martin, A.E.; Alba, A.L.; Hernando Mazon, A.; Blanch Mico, M.T.

    2016-07-01

    In our days we face a fundamental issue concerning road signs. We may display contents in vertical and horizontal format (static signs, variable message signs, road markings), either on a post, a gantry or a dashboard. And we foresee a coming age where the excellent matrix resolution of painted signs will be truly approached by the resolution of full matrix displays. But we also risk a babel context threatening the universal approach encouraged by international catalogues as the 1968 Convention (ECE/TRANS/196, 2007). And the fundamental risk comes from our decisions regarding how the transition from the contents and formats displayed on static message signs to the ones displayed on electronic signs (in gantries or dashboards) should be. Our work explores this issue specifically, considering the transition from Advance Direction Signs (static message signs, class G, 1 in the 1968 Convention) to what could be termed Advance Location Signs (signs concerning the location of variable events with regards to certain landmarks) developed as an adaptation of the G, 1 class to electronic traffic signs.(Author)

  14. Do Mangroves Subsidize Carbon to Adjacent Mudflat Fish Communities?

    Science.gov (United States)

    Henkel, S.; Kasten, S.; Hartmann, J.; Staubwasser, M.; Hernandez, M. F.; West, L.; Midway, S. R.; Polito, M. J.

    2017-12-01

    Mangroves are often implicated as energetic sources for fisheries productivity. However, the validity of this connection still remains in contention. Stable isotopes may provide answers by tracking the use of specific basal carbon sources in fish and invertebrates living in mangrove-mudflat habitat mosaics. We analyzed 307 consumer samples representing n=44 fish and invertebrate species collected from mangrove forest creeks and adjacent mudflats in coastal Tanzania using bulk carbon and nitrogen stable isotope analysis. Given the proposed high productivity of mangrove habitats, we hypothesize that mudflat communities will have carbon stable isotope values similar to mangrove communities either through the flux of mangrove carbon into adjacent mudflats and/or via the movement of mudflat fish communities into and out of mangrove habitats. Alternatively, mangrove carbon is often refractory, which may result in mudflat communities with isotopic values that differ from those found in adjacent mangrove communities. This scenario would suggest limited carbon flow between mudflat and mangrove food webs and that the movement of fish into and out of mangrove habitats is related to shelter from predation more than feeding. Data analysis is ongoing to test these competing hypotheses. By understanding the contribution of mangrove carbon to adjacent habitats, managers in Tanzania can make better informed decisions regarding the protection of mangroves and the local fisheries, which are a crucial source of income and food.

  15. Road Signs for UV-Completion

    CERN Document Server

    Dvali, Gia; Gomez, Cesar

    2012-01-01

    We confront the concepts of Wilsonian UV-completion versus self-completion by Classicalization in theories with derivatively-coupled scalars. We observe that the information about the UV-completion road is encoded in the sign of the derivative terms. We note that the sign of the derivative couplings for which there is no consistent Wilsonian UV-completion is the one that allows for consistent classicalons. This is an indication that for such a sign the vertex must be treated as fundamental and the theory self-protects against potential inconsistencies, such as superluminality, via self-completion by classicalization. Applying this reasoning to the UV-completion of the Standard Model, we see that the information about the Higgs versus classicalization is encoded in the sign of the scattering amplitude of longitudinal W-bosons. Negative sign excludes Higgs or any other weakly-coupled Wilsonian physics.

  16. Automatic Vessel Segmentation on Retinal Images

    Institute of Scientific and Technical Information of China (English)

    Chun-Yuan Yu; Chia-Jen Chang; Yen-Ju Yao; Shyr-Shen Yu

    2014-01-01

    Several features of retinal vessels can be used to monitor the progression of diseases. Changes in vascular structures, for example, vessel caliber, branching angle, and tortuosity, are portents of many diseases such as diabetic retinopathy and arterial hyper-tension. This paper proposes an automatic retinal vessel segmentation method based on morphological closing and multi-scale line detection. First, an illumination correction is performed on the green band retinal image. Next, the morphological closing and subtraction processing are applied to obtain the crude retinal vessel image. Then, the multi-scale line detection is used to fine the vessel image. Finally, the binary vasculature is extracted by the Otsu algorithm. In this paper, for improving the drawbacks of multi-scale line detection, only the line detectors at 4 scales are used. The experimental results show that the accuracy is 0.939 for DRIVE (digital retinal images for vessel extraction) retinal database, which is much better than other methods.

  17. The Use of Sign Language Pronouns by Native-Signing Children with Autism

    Science.gov (United States)

    Shield, Aaron; Meier, Richard P.; Tager-Flusberg, Helen

    2015-01-01

    We report the first study on pronoun use by an under-studied research population, children with autism spectrum disorder (ASD) exposed to American Sign Language from birth by their deaf parents. Personal pronouns cause difficulties for hearing children with ASD, who sometimes reverse or avoid them. Unlike speech pronouns, sign pronouns are…

  18. Nuclear reactor construction with bottom supported reactor vessel

    International Nuclear Information System (INIS)

    Sharbaugh, J.E.

    1987-01-01

    This patent describes an improved liquid metal nuclear reactor construction comprising: (a) a nuclear reactor core having a bottom platform support structure; (b) a reactor vessel for holding a large pool of low pressure liquid metal coolant and housing the core; (c) a containment structure surrounding the reactor vessel and having a sidewall spaced outwardly from the reactor vessel side wall and having a base mat spaced below the reactor vessel bottom end wall; (d) a central small diameter post anchored to the containment structure base mat and extending upwardly to the reactor vessel to axially fix the bottom end wall of the reactor vessel and provide a center column support for the lower end of the reactor core; (e) annular support structure disposed in the reactor vessel on the bottom end wall and extending about the lower end of the core; (f) structural support means disposed between the containment structure base mat and bottom end of the reactor vessel wall and cooperating for supporting the reactor vessel at its bottom end wall on the containment structure base mat to allow the reactor vessel to expand radially but substantially prevent any lateral motions that might be imposed by the occurrence of a seismic event; (g) a bed of insulating material disposed between the containment structure base mat and the bottom end wall of the reactor vessel and uniformly supporting the reactor vessel at its bottom end wall; freely expand radially from the central post as it heats up while providing continuous support thereof; (h) a deck supported upon the wall of the containment vessel above the top open end of the reactor vessel; and (i) extendible and retractable coupling means extending between the deck and the top open end of the reactor vessel and flexibly and sealably interconnecting the reactor vessel at its top end to the deck

  19. Vacuum vessel for thermonuclear device

    International Nuclear Information System (INIS)

    Kikuchi, Mitsuru; Nagashima, Keisuke; Suzuki, Masaru; Onozuka, Masaki.

    1997-01-01

    A vacuum vessel main body and structural members at the inside and the outside of the vacuum vessel main body are constituted by structural materials activated by irradiation of neutrons from plasmas such as stainless steels. Shielding members comprising tungsten or molybdenum are disposed on the surface of the vacuum vessel main body and the structural members of the inside and the outside of the main body. The shielding members have a function also as first walls or a seat member for the first walls. Armor tiles may be disposed to the shielding members. The shielding members and the armor tiles are secured to a securing seat member disposed, for example, to an inner plate of the vacuum vessel main body by bolts. Since the shielding members are disposed, it is not necessary to constitute the vacuum vessel main body and the structural members at the inside and the outside thereof by using a low activation material which is less activated, such as a titanium alloy. (I.N.)

  20. Vacuum vessel for thermonuclear device

    Energy Technology Data Exchange (ETDEWEB)

    Kikuchi, Mitsuru; Nagashima, Keisuke [Japan Atomic Energy Research Inst., Tokyo (Japan); Suzuki, Masaru; Onozuka, Masaki

    1997-07-11

    A vacuum vessel main body and structural members at the inside and the outside of the vacuum vessel main body are constituted by structural materials activated by irradiation of neutrons from plasmas such as stainless steels. Shielding members comprising tungsten or molybdenum are disposed on the surface of the vacuum vessel main body and the structural members of the inside and the outside of the main body. The shielding members have a function also as first walls or a seat member for the first walls. Armor tiles may be disposed to the shielding members. The shielding members and the armor tiles are secured to a securing seat member disposed, for example, to an inner plate of the vacuum vessel main body by bolts. Since the shielding members are disposed, it is not necessary to constitute the vacuum vessel main body and the structural members at the inside and the outside thereof by using a low activation material which is less activated, such as a titanium alloy. (I.N.)

  1. Nonlinear spin wave coupling in adjacent magnonic crystals

    Energy Technology Data Exchange (ETDEWEB)

    Sadovnikov, A. V., E-mail: sadovnikovav@gmail.com; Nikitov, S. A. [Laboratory “Metamaterials,” Saratov State University, Saratov 410012 (Russian Federation); Kotel' nikov Institute of Radioengineering and Electronics, Russian Academy of Sciences, Moscow 125009 (Russian Federation); Beginin, E. N.; Morozova, M. A.; Sharaevskii, Yu. P.; Grishin, S. V.; Sheshukova, S. E. [Laboratory “Metamaterials,” Saratov State University, Saratov 410012 (Russian Federation)

    2016-07-25

    We have experimentally studied the coupling of spin waves in the adjacent magnonic crystals. Space- and time-resolved Brillouin light-scattering spectroscopy is used to demonstrate the frequency and intensity dependent spin-wave energy exchange between the side-coupled magnonic crystals. The experiments and the numerical simulation of spin wave propagation in the coupled periodic structures show that the nonlinear phase shift of spin wave in the adjacent magnonic crystals leads to the nonlinear switching regime at the frequencies near the forbidden magnonic gap. The proposed side-coupled magnonic crystals represent a significant advance towards the all-magnonic signal processing in the integrated magnonic circuits.

  2. Nonlinear spin wave coupling in adjacent magnonic crystals

    International Nuclear Information System (INIS)

    Sadovnikov, A. V.; Nikitov, S. A.; Beginin, E. N.; Morozova, M. A.; Sharaevskii, Yu. P.; Grishin, S. V.; Sheshukova, S. E.

    2016-01-01

    We have experimentally studied the coupling of spin waves in the adjacent magnonic crystals. Space- and time-resolved Brillouin light-scattering spectroscopy is used to demonstrate the frequency and intensity dependent spin-wave energy exchange between the side-coupled magnonic crystals. The experiments and the numerical simulation of spin wave propagation in the coupled periodic structures show that the nonlinear phase shift of spin wave in the adjacent magnonic crystals leads to the nonlinear switching regime at the frequencies near the forbidden magnonic gap. The proposed side-coupled magnonic crystals represent a significant advance towards the all-magnonic signal processing in the integrated magnonic circuits.

  3. Vessels in Transit - Web Tool

    Data.gov (United States)

    Department of Transportation — A web tool that provides real-time information on vessels transiting the Saint Lawrence Seaway. Visitors may sort by order of turn, vessel name, or last location in...

  4. High-performance fiber/epoxy composite pressure vessels

    Science.gov (United States)

    Chiao, T. T.; Hamstad, M. A.; Jessop, E. S.; Toland, R. H.

    1978-01-01

    Activities described include: (1) determining the applicability of an ultrahigh-strength graphite fiber to composite pressure vessels; (2) defining the fatigue performance of thin-titanium-lined, high-strength graphite/epoxy pressure vessel; (3) selecting epoxy resin systems suitable for filament winding; (4) studying the fatigue life potential of Kevlar 49/epoxy pressure vessels; and (5) developing polymer liners for composite pressure vessels. Kevlar 49/epoxy and graphite fiber/epoxy pressure vessels, 10.2 cm in diameter, some with aluminum liners and some with alternation layers of rubber and polymer were fabricated. To determine liner performance, vessels were subjected to gas permeation tests, fatigue cycling, and burst tests, measuring composite performance, fatigue life, and leak rates. Both the metal and the rubber/polymer liner performed well. Proportionately larger pressure vessels (20.3 and 38 cm in diameter) were made and subjected to the same tests. In these larger vessels, line leakage problems with both liners developed the causes of the leaks were identified and some solutions to such liner problems are recommended.

  5. Reactor vessel supported by flexure member

    International Nuclear Information System (INIS)

    Crawford, J.D.; Pankow, B.

    1975-01-01

    A description is given of a reactor pressure vessel which is provided with vertical support means in the form of circumferentially spaced columns upon which the vessel is mounted. The columns are adapted to undergo flexure in order to accommodate the thermally induced displacements experienced by the vessel during operational transients

  6. 50 CFR 648.4 - Vessel permits.

    Science.gov (United States)

    2010-10-01

    ... carrying passengers for hire. (8) Atlantic bluefish vessels. (i) Commercial. Any vessel of the United... lands Atlantic bluefish in or from the EEZ in excess of the recreational possession limit specified at § 648.164 must have been issued and carry on board a valid commercial bluefish vessel permit. (ii) Party...

  7. Histomorphological changes of vessel structure in head and neck vessels following preoperative or postoperative radiotherapy

    International Nuclear Information System (INIS)

    Schultze-Mosgau, S.; Wehrhan, F.; Wiltfang, J.; Grabenbauer, G.G.; Sauer, R.; Roedel, F.; Radespiel-Troeger, M.

    2002-01-01

    Patients and Methods: In 348 patients (October 1995-March 2002) receiving primarly or secondarily 356 microvascular hard- and soft tissue reconstruction, a total of 209 vessels were obtained from neck recipient vessels and transplant vessels during anastomosis. Three groups were analysed: group 1 (27 patients) treated with no radiotherapy or chemotherapy; group 2 (29 patients) treated with preoperative irradiation (40-50 Gy) and chemotherapy (800 mg/m 2 /day 5-FU and 20 mg/m 2 /day cisplatin) 1.5 months prior to surgery; group 3 (20 patients) treated with radiotherapy (60-70 Gy) (median interval 78.7 months; IQR: 31.3 months) prior to surgery. From each of the 209 vessel specimens, 3 sections were investigated histomorphometrically, qualitatively and quantitatively (ratio media area/total vessel area) by NIH-Image-digitized measurements. To evaluate these changes as a function of age, radiation dose and chemotherapy, a statistical analysis was performed using an analysis of covariance and χ 2 tests (p > 0.05, SPSS V10). Results: In group 3, qualitative changes (intima dehiscence, hyalinosis) were found in recipient arteries significantly more frequently than in groups 1 and 2. For group 3 recipient arteries, histomorphometry revealed a significant decrease in the ratio media area/total vessel area (median 0.51, IQR 0.10) in comparison with groups 1 (p = 0.02) (median 0.61, IQR 0.29) and 2 (p = 0.046) (median 0.58, IQR 0.19). No significant difference was found between the vessels of groups 1 and 2 (p = 0.48). There were no significant differences in transplant arteries and recipient or transplant veins between the groups. Age and chemotherapy did not appear to have a significant influence on vessel changes in this study (p > 0.05). Conclusions: Following irradiation with 60-70 Gy, significant qualitative and quantitative histological changes to the recipient arteries, but not to the recipient veins, could be observed. In contrast, irradiation at a dose of 40-50 Gy

  8. The predictive accuracy of the black hole sign and the spot sign for hematoma expansion in patients with spontaneous intracerebral hemorrhage.

    Science.gov (United States)

    Yu, Zhiyuan; Zheng, Jun; Ma, Lu; Guo, Rui; Li, Mou; Wang, Xiaoze; Lin, Sen; Li, Hao; You, Chao

    2017-09-01

    In patients with spontaneous intracerebral hemorrhage (sICH), hematoma expansion (HE) is associated with poor outcome. Spot sign and black hole sign are neuroimaging predictors for HE. This study was aimed to compare the predictive value of two signs for HE. Within 6 h after onset of sICH, patients were screened for the computed tomography angiography spot sign and the non-contrast computed tomography black hole sign. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of two signs for HE prediction were calculated. The accuracy of two signs in predicting HE was analyzed by receiver-operator analysis. A total of 129 patients were included in this study. Spot sign was identified in 30 (23.3%) patients and black hole sign in 29 (22.5%) patients, respectively. Of 32 patients with HE, spot sign was observed in 19 (59.4%) and black hole sign was found in 14 (43.8%). The occurrence of black hole sign was significantly associated with spot sign (P black hole sign for predicting HE were 43.75, 84.54, 48.28, and 82.00%, respectively. The area under the curve was 0.740 for spot sign and 0.641 for black hole sign. (P = 0.228) Both spot sign and black hole sign appeared to have good predictive value for HE, and spot sign seemed to be a better predictor.

  9. In-vessel core debris retention through external flooding of the reactor pressure vessel. State-of-the-art report

    Energy Technology Data Exchange (ETDEWEB)

    Heel, A.M.J.M. van

    1995-07-01

    An overview of the state-of-the-art knowledge on the ex-vessel flooding accident management strategy for severe accidents in a NPP has been given. The feasibility has been discussed, as well as the in- and ex-vessel phenomena, which influence the structural integrity of the vessel. Finally, some computer codes with the ability to model the phenomena involved in ex-vessel flooding have been discussed. (orig./HP).

  10. In-vessel core debris retention through external flooding of the reactor pressure vessel. State-of-the-art report

    International Nuclear Information System (INIS)

    Heel, A.M.J.M. van.

    1995-07-01

    An overview of the state-of-the-art knowledge on the ex-vessel flooding accident management strategy for severe accidents in a NPP has been given. The feasibility has been discussed, as well as the in- and ex-vessel phenomena, which influence the structural integrity of the vessel. Finally, some computer codes with the ability to model the phenomena involved in ex-vessel flooding have been discussed. (orig./HP)

  11. 19 CFR 4.97 - Salvage vessels.

    Science.gov (United States)

    2010-04-01

    ... United States and Great Britain ‘concerning reciprocal rights for United States and Canada in the... meaning of this statute. (e) A Mexican vessel may engage in a salvage operation on a Mexican vessel in any territorial waters of the United States in which Mexican vessels are permitted to conduct such operations by...

  12. Vacuum vessel for thermonuclear device

    International Nuclear Information System (INIS)

    Hagiwara, Koji; Imura, Yasuya.

    1979-01-01

    Purpose: To provide constituted method for easily performing baking of vacuum vessel, using short-circuiting segments. Constitution: At the time of baking, one turn circuit is formed by the vacuum vessel and short-circuiting segments, and current transformer converting the one turn circuit into a secondary circuit by the primary coil and iron core is formed, and the vacuum vessel is Joule heated by an induction current from the primary coil. After completion of baking, the short-circuiting segments are removed. (Kamimura, M.)

  13. 33 CFR 148.217 - How can a State be designated as an adjacent coastal State?

    Science.gov (United States)

    2010-07-01

    ... an adjacent coastal State? 148.217 Section 148.217 Navigation and Navigable Waters COAST GUARD... General § 148.217 How can a State be designated as an adjacent coastal State? (a) Adjacent coastal States... as an adjacent coastal State in the notice may request to be designated as one if the environmental...

  14. Sociolinguistic Typology and Sign Languages.

    Science.gov (United States)

    Schembri, Adam; Fenlon, Jordan; Cormier, Kearsy; Johnston, Trevor

    2018-01-01

    This paper examines the possible relationship between proposed social determinants of morphological 'complexity' and how this contributes to linguistic diversity, specifically via the typological nature of the sign languages of deaf communities. We sketch how the notion of morphological complexity, as defined by Trudgill (2011), applies to sign languages. Using these criteria, sign languages appear to be languages with low to moderate levels of morphological complexity. This may partly reflect the influence of key social characteristics of communities on the typological nature of languages. Although many deaf communities are relatively small and may involve dense social networks (both social characteristics that Trudgill claimed may lend themselves to morphological 'complexification'), the picture is complicated by the highly variable nature of the sign language acquisition for most deaf people, and the ongoing contact between native signers, hearing non-native signers, and those deaf individuals who only acquire sign languages in later childhood and early adulthood. These are all factors that may work against the emergence of morphological complexification. The relationship between linguistic typology and these key social factors may lead to a better understanding of the nature of sign language grammar. This perspective stands in contrast to other work where sign languages are sometimes presented as having complex morphology despite being young languages (e.g., Aronoff et al., 2005); in some descriptions, the social determinants of morphological complexity have not received much attention, nor has the notion of complexity itself been specifically explored.

  15. Sociolinguistic Typology and Sign Languages

    Science.gov (United States)

    Schembri, Adam; Fenlon, Jordan; Cormier, Kearsy; Johnston, Trevor

    2018-01-01

    This paper examines the possible relationship between proposed social determinants of morphological ‘complexity’ and how this contributes to linguistic diversity, specifically via the typological nature of the sign languages of deaf communities. We sketch how the notion of morphological complexity, as defined by Trudgill (2011), applies to sign languages. Using these criteria, sign languages appear to be languages with low to moderate levels of morphological complexity. This may partly reflect the influence of key social characteristics of communities on the typological nature of languages. Although many deaf communities are relatively small and may involve dense social networks (both social characteristics that Trudgill claimed may lend themselves to morphological ‘complexification’), the picture is complicated by the highly variable nature of the sign language acquisition for most deaf people, and the ongoing contact between native signers, hearing non-native signers, and those deaf individuals who only acquire sign languages in later childhood and early adulthood. These are all factors that may work against the emergence of morphological complexification. The relationship between linguistic typology and these key social factors may lead to a better understanding of the nature of sign language grammar. This perspective stands in contrast to other work where sign languages are sometimes presented as having complex morphology despite being young languages (e.g., Aronoff et al., 2005); in some descriptions, the social determinants of morphological complexity have not received much attention, nor has the notion of complexity itself been specifically explored. PMID:29515506

  16. Sociolinguistic Typology and Sign Languages

    Directory of Open Access Journals (Sweden)

    Adam Schembri

    2018-02-01

    Full Text Available This paper examines the possible relationship between proposed social determinants of morphological ‘complexity’ and how this contributes to linguistic diversity, specifically via the typological nature of the sign languages of deaf communities. We sketch how the notion of morphological complexity, as defined by Trudgill (2011, applies to sign languages. Using these criteria, sign languages appear to be languages with low to moderate levels of morphological complexity. This may partly reflect the influence of key social characteristics of communities on the typological nature of languages. Although many deaf communities are relatively small and may involve dense social networks (both social characteristics that Trudgill claimed may lend themselves to morphological ‘complexification’, the picture is complicated by the highly variable nature of the sign language acquisition for most deaf people, and the ongoing contact between native signers, hearing non-native signers, and those deaf individuals who only acquire sign languages in later childhood and early adulthood. These are all factors that may work against the emergence of morphological complexification. The relationship between linguistic typology and these key social factors may lead to a better understanding of the nature of sign language grammar. This perspective stands in contrast to other work where sign languages are sometimes presented as having complex morphology despite being young languages (e.g., Aronoff et al., 2005; in some descriptions, the social determinants of morphological complexity have not received much attention, nor has the notion of complexity itself been specifically explored.

  17. Structural analysis of the KSTAR vacuum vessel

    Energy Technology Data Exchange (ETDEWEB)

    In, Sang Ryul; Yoon, Byeong Joo [Korea Atomic Energy Research Institute, Taejon (Korea)

    1998-10-01

    Structure analysis of the vacuum vessel for the KSTAR tokamak which, is in the end phase of the conceptual design have been performed. Mechanical stresses and deformations of the vessel produced by constant forces due to atmospheric pressure, dead weight, fluid pressure, etc and various transient electromagnetic forces induced during tokamak operations were calculated as well as modal characteristics and buckling properties were investigated. Influences of the temperature gradient and the constraint condition of the support on the thermal stress and deformation of the vessel were analyzed. The thermal stress due to the temperature distribution on the vessel as supplying the N{sub 2} gas of 400 deg C through poloidal channels according to the recent baking concept were calculated. No severe problem in the robustness of the vessel was found when applying the constant pressures on the vessel. However the mechanical stress due to the EM force induced by halo currents flowing on the vessel and the plasma facing components (PFCs) far exceeded the allowable limit. Some reinforcing components should be added on the boundary of the PFC support and the vessel, and that of the vessel support and the vessel. A steep temperature gradient in the vicinity of the inlet and oulet of the heating gas produced a thermal stress much higher than allowable. It is necessary to make the temperature of the vessel as uniform as possible and to develop a new support concept which is flexible enough to accommodate a thermal expansion of a few cm while sufficiently strong to resist mechanical impacts. (author). 5 refs., 41 figs., 9 tabs.

  18. Adapting tests of sign language assessment for other sign languages--a review of linguistic, cultural, and psychometric problems.

    Science.gov (United States)

    Haug, Tobias; Mann, Wolfgang

    2008-01-01

    Given the current lack of appropriate assessment tools for measuring deaf children's sign language skills, many test developers have used existing tests of other sign languages as templates to measure the sign language used by deaf people in their country. This article discusses factors that may influence the adaptation of assessment tests from one natural sign language to another. Two tests which have been adapted for several other sign languages are focused upon: the Test for American Sign Language and the British Sign Language Receptive Skills Test. A brief description is given of each test as well as insights from ongoing adaptations of these tests for other sign languages. The problems reported in these adaptations were found to be grounded in linguistic and cultural differences, which need to be considered for future test adaptations. Other reported shortcomings of test adaptation are related to the question of how well psychometric measures transfer from one instrument to another.

  19. 33 CFR 151.1512 - Vessel safety.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Vessel safety. 151.1512 Section... River § 151.1512 Vessel safety. Nothing in this subpart relieves the master of the responsibility for ensuring the safety and stability of the vessel or the safety of the crew and passengers, or any other...

  20. Vitamin D Status in Small Vessel and Large Vessel Ischemic Stroke Patients: A Case–control Study

    Directory of Open Access Journals (Sweden)

    Navid Manouchehri

    2017-01-01

    Full Text Available Background: Vitamin D insufficiency is a globally widespread issue. Recent studies have reported a high prevalence of Vitamin D deficiency in Middle-East countries. Studies have shown negative effects of Vitamin D deficiency on endothelium and related diseases such as ischemic brain stroke. Here, we assessed Vitamin D status in patients with different types of ischemic brain stroke and control group. Materials and Methods: Seventy-five patients (49.3% small vessel, 50.7% large vessel and 75 controls, matched for age (68.01 ± 10.94 vs. 67.64 ± 10.24 and sex (42 male and 33 female were recruited. 25(OH D levels were measured by Chemiluminescence immunoassay. 25(OH D status was considered as severely, moderately, or mildly deficient and normal with 25(OH D levels of less than 5, 5-10, 10-16, and> 16 ng/ml, respectively. Results: Mean ± standard error concentration of 25(OH D in cases and controls were 17.7 ± 1.5 and 26.9 ± 1.6 (P = 0.0001, respectively. Mild, moderate, and severe Vitamin D deficiency were observed in 10.8%, 32.4%, 8.1% vs. 34.3%, 31.5%, 9.5% of small vessel and large vessel group, respectively. 21.7% of the controls were Vitamin D deficient. Vitamin D deficiency was significantly associated with higher risk for ischemic stroke, (P = 0.000, OR = 7.17, 95% confidence interval: 3.36–15.29. 25(OH D levels were significantly higher in control group comparing to small vessel (26.9 ± 1.6 vs. 20.59 ± 2.6 P < 0.05 and large vessel (26.9 ± 1.6 vs. 13.4 ± 1.3 P < 0.001 stroke patients. Small vessel group had significantly higher levels of Vitamin D than large vessel (P < 0.05. Conclusion: Vitamin D deficiency significantly increases the risk of ischemic stroke, favoring the types with the pathogenesis of large vessel strokes.

  1. Sociolinguistic Typology and Sign Languages

    OpenAIRE

    Adam Schembri; Jordan Fenlon; Kearsy Cormier; Trevor Johnston

    2018-01-01

    This paper examines the possible relationship between proposed social determinants of morphological ‘complexity’ and how this contributes to linguistic diversity, specifically via the typological nature of the sign languages of deaf communities. We sketch how the notion of morphological complexity, as defined by Trudgill (2011), applies to sign languages. Using these criteria, sign languages appear to be languages with low to moderate levels of morphological complexity. This may partly reflec...

  2. AFSC/FMA/Vessel Assessment Logging

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Vessels fishing trawl gear, vessels fishing hook-and-line and pot gear that are also greater than 57.5 feet overall, and shoreside and floating processing facilities...

  3. Fluorides leaching from restorative materials and the effect on adjacent teeth

    DEFF Research Database (Denmark)

    Qvist, Vibeke; Poulsen, Agneta; Teglers, Poul Thorpen

    2010-01-01

    Placing a Class II restoration in a tooth changes the local environment, including that for the adjacent tooth. Apart from the change to a less- or non-cariogenic environment for the restored tooth, the effect of leachable components from a restoration in the adjacent tooth should be taken into c...

  4. Vessel size measurements in angiograms: Manual measurements

    International Nuclear Information System (INIS)

    Hoffmann, Kenneth R.; Dmochowski, Jacek; Nazareth, Daryl P.; Miskolczi, Laszlo; Nemes, Balazs; Gopal, Anant; Wang Zhou; Rudin, Stephen; Bednarek, Daniel R.

    2003-01-01

    Vessel size measurement is perhaps the most often performed quantitative analysis in diagnostic and interventional angiography. Although automated vessel sizing techniques are generally considered to have good accuracy and precision, we have observed that clinicians rarely use these techniques in standard clinical practice, choosing to indicate the edges of vessels and catheters to determine sizes and calibrate magnifications, i.e., manual measurements. Thus, we undertook an investigation of the accuracy and precision of vessel sizes calculated from manually indicated edges of vessels. Manual measurements were performed by three neuroradiologists and three physicists. Vessel sizes ranged from 0.1-3.0 mm in simulation studies and 0.3-6.4 mm in phantom studies. Simulation resolution functions had full-widths-at-half-maximum (FWHM) ranging from 0.0 to 0.5 mm. Phantom studies were performed with 4.5 in., 6 in., 9 in., and 12 in. image intensifier modes, magnification factor = 1, with and without zooming. The accuracy and reproducibility of the measurements ranged from 0.1 to 0.2 mm, depending on vessel size, resolution, and pixel size, and zoom. These results indicate that manual measurements may have accuracies comparable to automated techniques for vessels with sizes greater than 1 mm, but that automated techniques which take into account the resolution function should be used for vessels with sizes smaller than 1 mm

  5. Variable impact of CSF flow suppression on quantitative 3.0T intracranial vessel wall measurements.

    Science.gov (United States)

    Cogswell, Petrice M; Siero, Jeroen C W; Lants, Sarah K; Waddle, Spencer; Davis, L Taylor; Gilbert, Guillaume; Hendrikse, Jeroen; Donahue, Manus J

    2018-03-31

    Flow suppression techniques have been developed for intracranial (IC) vessel wall imaging (VWI) and optimized using simulations; however, simulation results may not translate in vivo. To evaluate experimentally how IC vessel wall and lumen measurements change in identical subjects when evaluated using the most commonly available blood and cerebrospinal fluid (CSF) flow suppression modules and VWI sequences. Prospective. Healthy adults (n = 13; age = 37 ± 15 years) were enrolled. A 3.0T 3D T 1 /proton density (PD)-weighted turbo-spin-echo (TSE) acquisition with post-readout anti-driven equilibrium module, with and without Delay-Alternating-with-Nutation-for-Tailored-Excitation (DANTE) was applied. DANTE flip angle (8-12°) and TSE refocusing angle (sweep = 40-120° or 50-120°) were varied. Basilar artery and internal carotid artery (ICA) wall thicknesses, CSF signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and signal ratio (SR) were assessed. Measurements were made by two readers (radiology resident and board-certified neuroradiologist). A Wilcoxon signed-rank test was applied with corrected two-sided P CSF suppression. Addition of the DANTE preparation reduced CSF SNR from 17.4 to 6.7, thereby providing significant (P CSF suppression. The DANTE preparation also resulted in a significant (P CSF CNR improvement (P = 0.87). There was a trend for a difference in blood SNR with vs. without DANTE (P = 0.05). The outer vessel wall diameter and wall thickness values were lower (P CSF suppression and CNR of the approaches evaluated. However, improvements are heterogeneous, likely owing to intersubject vessel pulsatility and CSF flow variations, which can lead to variable flow suppression efficacy in these velocity-dependent modules. 2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018. © 2018 International Society for Magnetic Resonance in Medicine.

  6. Phonological Development in Hearing Learners of a Sign Language: The Influence of Phonological Parameters, Sign Complexity, and Iconicity

    Science.gov (United States)

    Ortega, Gerardo; Morgan, Gary

    2015-01-01

    The present study implemented a sign-repetition task at two points in time to hearing adult learners of British Sign Language and explored how each phonological parameter, sign complexity, and iconicity affected sign production over an 11-week (22-hour) instructional period. The results show that training improves articulation accuracy and that…

  7. Standardization of Sign Languages

    Science.gov (United States)

    Adam, Robert

    2015-01-01

    Over the years attempts have been made to standardize sign languages. This form of language planning has been tackled by a variety of agents, most notably teachers of Deaf students, social workers, government agencies, and occasionally groups of Deaf people themselves. Their efforts have most often involved the development of sign language books…

  8. Assessment of reactor vessel integrity (ARVI)

    Energy Technology Data Exchange (ETDEWEB)

    Sehgal, B.R. E-mail: sehgal@ne.kth.se; Theerthan, A.; Giri, A.; Karbojian, A.; Willschuetz, H.G.; Kymaelaeinen, O.; Vandroux, S.; Bonnet, J.M.; Seiler, J.M.; Ikkonen, K.; Sairanen, R.; Bhandari, S.; Buerger, M.; Buck, M.; Widmann, W.; Dienstbier, J.; Techy, Z.; Kostka, P.; Taubner, R.; Theofanous, T.; Dinh, T.N

    2003-04-01

    The cost-shared project ARVI (assessment of reactor vessel integrity) involves a total of nine organisations from Europe and USA. The objective of the ARVI Project is to resolve the safety issues that remain unresolved for the melt vessel interaction phase of the in-vessel progression of a severe accident. The work consists of experiments and analysis development. Four tests were performed in the EC-FOREVER Programme, in which failure was achieved in-vessels employing the French pressure vessel steel. The tests were analysed with the commercial code ANSYS-Multiphysics, and the codes SYSTUS+ and PASULA, and quite good agreement was achieved for the failure location. Natural convection experiments in stratified pools have been performed in the SIMECO and the COPO facilities, which showed that much greater heat is transferred downwards for immiscible layers or before layers mix. A model for gap cooling and a set of simplified models for the system codes have been developed. MVITA code calculations have been performed for the Czech and Hungarian VVERs, towards evaluation of the in-vessel melt retention accident management scheme. Tests have been performed at the ULPU facility with organised flow for vessel external cooling. Considerable enhancement of the critical heat flux (CHF) was obtained. The ARVI Project has reached the halfway stage. This paper presents the results obtained thus far from the project.

  9. Quantifying the effect of disruptions to temporal coherence on the intelligibility of compressed American Sign Language video

    Science.gov (United States)

    Ciaramello, Frank M.; Hemami, Sheila S.

    2009-02-01

    Communication of American Sign Language (ASL) over mobile phones would be very beneficial to the Deaf community. ASL video encoded to achieve the rates provided by current cellular networks must be heavily compressed and appropriate assessment techniques are required to analyze the intelligibility of the compressed video. As an extension to a purely spatial measure of intelligibility, this paper quantifies the effect of temporal compression artifacts on sign language intelligibility. These artifacts can be the result of motion-compensation errors that distract the observer or frame rate reductions. They reduce the the perception of smooth motion and disrupt the temporal coherence of the video. Motion-compensation errors that affect temporal coherence are identified by measuring the block-level correlation between co-located macroblocks in adjacent frames. The impact of frame rate reductions was quantified through experimental testing. A subjective study was performed in which fluent ASL participants rated the intelligibility of sequences encoded at a range of 5 different frame rates and with 3 different levels of distortion. The subjective data is used to parameterize an objective intelligibility measure which is highly correlated with subjective ratings at multiple frame rates.

  10. In vivo experimental study on laser welded ICG-loaded chitosan patches for vessel repair

    Science.gov (United States)

    Rossi, Francesca; Matteini, Paolo; Esposito, Giuseppe; Albanese, Alessio; Puca, Alfredo; Maira, Giulio; Rossi, Giacomo; Pini, Roberto

    2011-03-01

    Laser welding of microvessels provides several advantages over conventional suturing techniques: surgical times reduction, vascular healing process improvement, tissue damage reduction. We present the first application of biopolymeric patches in an in vivo laser assisted procedure for vessel repair. The study was performed in 20 New Zealand rabbits. After anesthesia, a 3-cm segment of the right common carotid artery was exposed and clamped proximally and distally. A linear lesion 3 mm in length was carried out. We used a diode laser emitting at 810 nm and equipped with a 300 μm diameter optical fiber. To close the cut, ICG-loaded chitosan films were prepared: chitosan is characterized by biodegradability, biocompatibility, antimicrobial, haemostatic and wound healing-promoting activity. ICG is an organic chromophore commonly used in the laser welding procedures to mediate the photothermal conversion at the basis of the welding effect. The membranes were used to wrap the whole length of the cut, and then they were welded in the correct position by delivering single laser spots to induce local patch/tissue adhesion. The result is an immediate closure of the wound, with no bleeding at clamps release. The animals were observed during follow-up and sacrificed after 2, 7, 30 and 90 days. All the repaired vessels were patent, no bleeding signs were documented. The carotid samples underwent histological examinations. The advantages of the proposed technique are: simplification of the surgical procedure and shortening of the operative time; good strength of the vessel repair; decreased foreign-body reaction, reduced inflammatory response and improved vascular healing process.

  11. Neutron Assay System for Confinement Vessel Disposition

    International Nuclear Information System (INIS)

    Frame, Katherine C.; Bourne, Mark M.; Crooks, William J.; Evans, Louise; Mayo, Douglas R.; Miko, David K.; Salazar, William R.; Stange, Sy; Valdez, Jose I.; Vigil, Georgiana M.

    2012-01-01

    Los Alamos National Laboratory has a number of spherical confinement vessels (CVs) remaining from tests involving nuclear materials. These vessels have an inner diameter of 6 feet with 1-inch thick steel walls. The goal of the Confinement Vessel Disposition (CVD) project is to remove debris and reduce contamination inside the CVs. The Confinement Vessel Assay System (CVAS) was developed to measure the amount of special nuclear material (SNM) in CVs before and after cleanout. Prior to cleanout, the system will be used to perform a verification measurement of each vessel. After cleanout, the system will be used to perform safeguards-quality assays of (le)100-g 239 Pu equivalent in a vessel for safeguards termination. The CVAS has been tested and calibrated in preparation for verification and safeguards measurements.

  12. Containment vessel

    International Nuclear Information System (INIS)

    Zbirohowski-Koscia, K.F.; Roberts, A.C.

    1980-01-01

    A concrete containment vessel for nuclear reactors is disclosed that is spherical and that has prestressing tendons disposed in first, second and third sets, the tendons of each set being all substantially concentric and centred around a respective one of the three orthogonal axes of the sphere; the tendons of the first set being anchored at each end at a first anchor rib running around a circumference of the vessel, the tendons of the second set being anchored at each end at a second anchor rib running around a circumference of the sphere and disposed at 90 0 to the first rib, and the tendons of the third set being anchored some to the first rib and the remainder to the second rib. (author)

  13. Nuclear reactor pressure vessel-specific flaw distribution development

    International Nuclear Information System (INIS)

    Rosinski, S.T.

    1992-01-01

    Vessel integrity predictions performed through fracture mechanics analysis of a pressurized thermal shock event have been shown to be significantly sensitive to the overall flaw distribution input. It has also been shown that modem vessel in-service inspection (ISI) results can be used for development of vessel flaw distribution(s) that are more representative of US vessels. This paper describes the development and application of a methodology to analyze ISI data for the purpose of flaw distribution determination. The resultant methodology considers detection reliability, flaw sizing accuracy, and flaw detection threshold in its application. Application of the methodology was then demonstrated using four recently acquired US PWR vessel inspection data sets. Throughout the program, new insight was obtained into several key inspection performance and vessel integrity prediction practice issues that will impact future vessel integrity evaluation. For example, the potential application of a vessel-specific flaw distribution now provides at least one method by which a vessel-specific reference flaw size applicable to pressure-temperature limit curves determination can be estimated. This paper will discuss the development and application of the methodology and the impact to future vessel integrity analyses

  14. Integral experiments on in-vessel coolability and vessel creep: results and analysis of the FOREVER-C1 test

    Energy Technology Data Exchange (ETDEWEB)

    Sehgal, B.R.; Nourgaliev, R.R.; Dinh, T.N.; Karbojian, A. [Division of Nuclear Power Safety, Royal Institute of Technology, Drottning Kristinas Vaeg., Stockholm (Sweden)

    1999-07-01

    This paper describes the FOREVER (Failure Of REactor VEssel Retention) experimental program, which is currently underway at the Division of Nuclear Power Safety, Royal Institute of Technology (RIT/NPS). The objectives of the FOREVER experiments are to obtain data and develop validated models (i) on the melt coolability process inside the vessel, in the presence of water (in particular, on the efficacy of the postulated gap cooling to preclude vessel failure); and (ii) on the lower head failure due to the creep process in the absence of water inside and/or outside the lower head. The paper presents the experimental results and analysis of the first FOREVER-C1 test. During this experiment, the 1/10th scale pressure vessel, heated to about 900degC and pressurized to 26 bars, was subjected to creep deformation in a non-stop 24-hours test. The vessel wall displacement data clearly shows different stages of the vessel deformation due to thermal expansion, elastic, plastic and creep processes. The maximum displacement was observed at the lowermost region of the vessel lower plenum. Information on the FOREVER-C1 measured thermal characteristics and analysis of the observed thermal and structural behavior is presented. The coupled nature of thermal and mechanical processes, as well as the effect of other system conditions (such as depressurization) on the melt pool and vessel temperature responses are analyzed. (author)

  15. Prediction of Large Vessel Occlusions in Acute Stroke: National Institute of Health Stroke Scale Is Hard to Beat.

    Science.gov (United States)

    Vanacker, Peter; Heldner, Mirjam R; Amiguet, Michael; Faouzi, Mohamed; Cras, Patrick; Ntaios, George; Arnold, Marcel; Mattle, Heinrich P; Gralla, Jan; Fischer, Urs; Michel, Patrik

    2016-06-01

    Endovascular treatment for acute ischemic stroke with a large vessel occlusion was recently shown to be effective. We aimed to develop a score capable of predicting large vessel occlusion eligible for endovascular treatment in the early hospital management. Retrospective, cohort study. Two tertiary, Swiss stroke centers. Consecutive acute ischemic stroke patients (1,645 patients; Acute STroke Registry and Analysis of Lausanne registry), who had CT angiography within 6 and 12 hours of symptom onset, were categorized according to the occlusion site. Demographic and clinical information was used in logistic regression analysis to derive predictors of large vessel occlusion (defined as intracranial carotid, basilar, and M1 segment of middle cerebral artery occlusions). Based on logistic regression coefficients, an integer score was created and validated internally and externally (848 patients; Bernese Stroke Registry). None. Large vessel occlusions were present in 316 patients (21%) in the derivation and 566 (28%) in the external validation cohort. Five predictors added significantly to the score: National Institute of Health Stroke Scale at admission, hemineglect, female sex, atrial fibrillation, and no history of stroke and prestroke handicap (modified Rankin Scale score, < 2). Diagnostic accuracy in internal and external validation cohorts was excellent (area under the receiver operating characteristic curve, 0.84 both). The score performed slightly better than National Institute of Health Stroke Scale alone regarding prediction error (Wilcoxon signed rank test, p < 0.001) and regarding discriminatory power in derivation and pooled cohorts (area under the receiver operating characteristic curve, 0.81 vs 0.80; DeLong test, p = 0.02). Our score accurately predicts the presence of emergent large vessel occlusions, which are eligible for endovascular treatment. However, incorporation of additional demographic and historical information available on hospital arrival

  16. Pressure vessel integrity 1991

    International Nuclear Information System (INIS)

    Bhandari, S.; Doney, R.O.; McDonald, M.S.; Jones, D.P.; Wilson, W.K.; Pennell, W.E.

    1991-01-01

    This volume contains papers relating to the structural integrity assessment of pressure vessels and piping, with special emphasis on nuclear industry applications. The papers were prepared for technical sessions developed under the sponsorship of the ASME Pressure Vessels and Piping Division Committees for Codes and Standards, Computer Technology, Design and Analysis, and Materials Fabrication. They were presented at the 1991 Pressure Vessels and Piping Division Conference in San Diego, California, June 23-27. The primary objective of the sponsoring organization is to provide a forum for the dissemination and discussion of information on development and application of technology for the structural integrity assessment of pressure vessels and piping. This publication includes contributions from authors from Australia, France, Japan, Sweden, Switzerland, the United Kingdom, and the United States. The papers here are organized in six sections, each with a particular emphasis as indicated in the following section titles: Fracture Technology Status and Application Experience; Crack Initiation, Propagation and Arrest; Ductile Tearing; Constraint, Stress State, and Local-Brittle-Zones Effects; Computational Techniques for Fracture and Corrosion Fatigue; and Codes and Standards for Fatigue, Fracture and Erosion/Corrosion

  17. First insights into the functional role of vasicentric tracheids and parenchyma in eucalyptus species with solitary vessels: do they contribute to xylem efficiency or safety?

    Science.gov (United States)

    Barotto, Antonio José; Fernandez, María Elena; Gyenge, Javier; Meyra, Ariel; Martinez-Meier, Alejandro; Monteoliva, Silvia

    2016-12-01

    The relationship between hydraulic specific conductivity (k s ) and vulnerability to cavitation (VC) with size and number of vessels has been studied in many angiosperms. However, few of the studies link other cell types (vasicentric tracheids (VT), fibre-tracheids, parenchyma) with these hydraulic functions. Eucalyptus is one of the most important genera in forestry worldwide. It exhibits a complex wood anatomy, with solitary vessels surrounded by VT and parenchyma, which could serve as a good model to investigate the functional role of the different cell types in xylem functioning. Wood anatomy (several traits of vessels, VT, fibres and parenchyma) in conjunction with maximum k s and VC was studied in adult trees of commercial species with medium-to-high wood density (Eucalyptus globulus Labill., Eucalyptus viminalis Labill. and Eucalyptus camaldulensis Dehnh.). Traits of cells accompanying vessels presented correlations with functional variables suggesting that they contribute to both increasing connectivity between adjacent vessels-and, therefore, to xylem conduction efficiency-and decreasing the probability of embolism propagation into the tissue, i.e., xylem safety. All three species presented moderate-to-high resistance to cavitation (mean P 50 values = -2.4 to -4.2 MPa) with no general trade-off between efficiency and safety at the interspecific level. The results in these species do not support some well-established hypotheses of the functional meaning of wood anatomy. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  18. Phonological Similarity in American Sign Language.

    Science.gov (United States)

    Hildebrandt, Ursula; Corina, David

    2002-01-01

    Investigates deaf and hearing subjects' ratings of American Sign Language (ASL) signs to assess whether linguistic experience shapes judgments of sign similarity. Findings are consistent with linguistic theories that posit movement and location as core structural elements of syllable structure in ASL. (Author/VWL)

  19. Symmetry breaking of adjacent tracks in perpendicular recording system

    International Nuclear Information System (INIS)

    Xie Huang; Wei Dan

    2007-01-01

    The track density increase in a perpendicular magnetic recording system is limited by the adjacent-track interference (ATI). In this work, a composite micromagnetic simulation model of the read/write process is developed to analyse ATI by the symmetry of signal and noise in two adjacent W = 60 nm tracks with the track pitch of the order of 100 nm. Based on the two-dimensional medium noise distribution of dibit recording, it is found that the noise in the first and later recorded tracks start to be asymmetric when the track pitch is lower than 2 W; if the read width is limited within 2/3 of the write width, the asymmetry of noise appears when the track pitch is less than 1.5 W. At higher recording densities, the signal-to-noise ratio degradation is mainly due to the noise caused by the interference from the signal of the adjacent track. Side writing can be effectively eliminated by the use of a guard band whose width is at least half the track width

  20. Test of 6-in.-thick pressure vessels. Series 3: intermediate test vessel V-7A under sustained loading

    International Nuclear Information System (INIS)

    Bryan, R.H.; Cate, T.M.; Holz, P.P.; King, T.A.; Merkle, J.G.; Robinson, G.C.; Smith, G.C.; Smith, J.E.; Whitman, G.D.

    1978-01-01

    HSST intermediate test vessel V-7 was repaired after being tested hydrostatically to leakage and was retested pneumatically as vessel V-7A. Except for the method of applying the load, the conditions in both tests were nearly identical. In each case, a sharp outside surface flaw 547 mm long (18 in.) by about 135 mm deep (5.3 in.) was prepared in the 152-mm-thick (6-in.) test cylinder of A533, grade B, class 1 steel. The inside surface of vessel V-7A was sealed in the region of the flaw by a thin metal patch so that pressure could be sustained after rupture. Vessel V-7A failed by rupture of the flaw ligament without burst, as expected. Rupture occurred at 144.3 MPa (20.92 ksi), after which pressure was sustained for 30 min without any indication of instability. The rupture pressure of vessel V-7A was about 2 percent less than that of vessel V-7

  1. Altered expression of estrogen receptor-α variant messenger RNAs between adjacent normal breast and breast tumor tissues

    International Nuclear Information System (INIS)

    Leygue, Etienne; Dotzlaw, Helmut; Watson, Peter H; Murphy, Leigh C

    2000-01-01

    -α variant (ERD3) messenger RNA in tumor tissues and cancer cell lines versus independent normal reduction mammoplasty samples has recently been reported. These data were obtained in tissues from different individuals and possible interindividual differences cannot be excluded. The goal of this study was to investigate the expressions of ERC4, ERD5 and ERD3 variant messenger RNAs in normal breast tissues and their matched adjacent primary breast tumor tissues. Eighteen cases were selected from the Manitoba Breast Tumor Bank, which had well separated and histopathologically characterized normal and adjacent neoplastic components. All tumors were classified as primary invasive ductal carcinomas. Six tumors were ER-negative/progesterone receptor (PR)-negative, nine were ER-positive/PR-positive, two were ER-positive/PR-negative, and one was ER-negative/PR-positive, as measured by ligand-binding assay. For each specimen, total RNA was extracted from frozen normal and tumor tissue sections and was reverse transcribed. The expressions of ERC4, ERD3 and ERD5 messenger RNAs relative to WT ER-α messenger RNA were investigated by previously validated semiquantitative reverse transcription polymerase chain reaction (PCR) assays performed using three different sets of primers. As shown Figure 1a, two PCR products were obtained that corresponded to WT ER and ERC4 messenger RNAs. For each case, the mean of the ratios obtained in at least three independent PCR experiments is shown for both normal and tumor compartments (Fig 1b). A statistically higher ERC4 messenger RNA relative expression was found in the neoplastic components of ER-positive/PR-positive tumors, as compared with matched adjacent normal tissues (n = 9; P = 0.019, Wilcoxon signed-rank test). Two PCR products were obtained that corresponded to WT ER and ERD3 messenger RNAs (Fig 2a). A significantly higher expression of ERD3 messenger RNA was observed in the normal compared with the adjacent neoplastic components of ER

  2. Graywater Discharges from Vessels

    Science.gov (United States)

    2011-11-01

    metals (e.g., cadmium, chromium, lead, copper , zinc, silver, nickel, and mercury), solids, and nutrients (USEPA, 2008b; USEPA 2010). Wastewater from... flotation ), and disinfection (using ultraviolet light) as compared to traditional Type II MSDs that use either simple maceration and chlorination, or...Coliform Naval Vessels Oceanographic Vessels Small Cruise Ships 25a Vendor 2 Hamann AG Biological Treatment with Dissolved Air Flotation and

  3. Trapping of embolic particles in a vessel phantom by cavitation-enhanced acoustic streaming

    International Nuclear Information System (INIS)

    Maxwell, Adam D; Park, Simone; Cain, Charles A; Grotberg, James B; Xu, Zhen; Vaughan, Benjamin L

    2014-01-01

    Cavitation clouds generated by short, high-amplitude, focused ultrasound pulses were previously observed to attract, trap, and erode thrombus fragments in a vessel phantom. This phenomenon may offer a noninvasive method to capture and eliminate embolic fragments flowing through the bloodstream during a cardiovascular intervention. In this article, the mechanism of embolus trapping was explored by particle image velocimetry (PIV). PIV was used to examine the fluid streaming patterns generated by ultrasound in a vessel phantom with and without crossflow of blood-mimicking fluid. Cavitation enhanced streaming, which generated fluid vortices adjacent to the focus. The focal streaming velocity, u f , was as high as 120 cm/s, while mean crossflow velocities, u c , were imposed up to 14 cm/s. When a solid particle 3–4 mm diameter was introduced into crossflow, it was trapped near the focus. Increasing u f promoted particle trapping while increasing u c promoted particle escape. The maximum crossflow Reynolds number at which particles could be trapped, Re c , was approximately linear with focal streaming number, Re f , i.e. Re c = 0.25Re f + 67.44 (R 2 = 0.76) corresponding to dimensional velocities u c = 0.084u f + 3.122 for 20 < u f  < 120 cm/s. The fluidic pressure map was estimated from PIV and indicated a negative pressure gradient towards the focus, trapping the embolus near this location. (paper)

  4. The halo sign and peripancreatic fluid: useful CT signs of hypovolaemic shock complex in adults

    International Nuclear Information System (INIS)

    Ryan, M.F.; Hamilton, P.A.; Sarrazin, J.; Chu, P.; Benjaminov, O.; Lam, K.

    2005-01-01

    AIM: To report two new, useful computed tomography (CT) signs of the hypovolaemic shock complex (HSC) in adults admitted after blunt abdominal trauma: the halo sign (ring of fluid around a collapsed intra-hepatic inferior vena cava (IVC)), and peripancreatic retroperitoneal fluid. MATERIALS AND METHODS: CT images of 498 consecutive patients admitted after blunt abdominal trauma were reviewed, of which 27 had CT signs of the HSC. The CT images of these 27 patients were analysed. A control group of 101 patients examined using CT for suspected blunt abdominal trauma who did not have the HSC were chosen for comparison. RESULTS: The most common features involved the vascular compartment: diminished IVC diameter (n=27), a positive halo sign (n=21); diminished anteroposterior diameter of the aorta (n=13); and abnormal vascular enhancement (n=10). Peripancreatic retroperitoneal fluid in the absence of pancreatic injury, pancreatitis or pancreatic disease was observed in eight patients. Hollow visceral abnormalities included: diffuse increased mucosal enhancement of both the small and large bowel (n=19); diffuse thickening of the small bowel wall (n=11); and small bowel dilatation (n=7). Solid visceral abnormalities included both decreased and or increased enhancement. Several concomitant intra- and extra-abdominal injuries were also identified. CONCLUSION: In the setting of blunt abdominal trauma, early abdominal CT can show diffuse abnormalities due to the HSC, which occasionally may alert clinicians of unsuspected shock. Recognition of these signs as distinguished from injured viscera is important in order to avoid unnecessary laparotomy. Two new signs are described: the halo sign and peripancreatic retroperitoneal fluid

  5. The halo sign and peripancreatic fluid: useful CT signs of hypovolaemic shock complex in adults

    Energy Technology Data Exchange (ETDEWEB)

    Ryan, M.F.; Hamilton, P.A.; Sarrazin, J.; Chu, P.; Benjaminov, O.; Lam, K

    2005-05-01

    AIM: To report two new, useful computed tomography (CT) signs of the hypovolaemic shock complex (HSC) in adults admitted after blunt abdominal trauma: the halo sign (ring of fluid around a collapsed intra-hepatic inferior vena cava (IVC)), and peripancreatic retroperitoneal fluid. MATERIALS AND METHODS: CT images of 498 consecutive patients admitted after blunt abdominal trauma were reviewed, of which 27 had CT signs of the HSC. The CT images of these 27 patients were analysed. A control group of 101 patients examined using CT for suspected blunt abdominal trauma who did not have the HSC were chosen for comparison. RESULTS: The most common features involved the vascular compartment: diminished IVC diameter (n=27), a positive halo sign (n=21); diminished anteroposterior diameter of the aorta (n=13); and abnormal vascular enhancement (n=10). Peripancreatic retroperitoneal fluid in the absence of pancreatic injury, pancreatitis or pancreatic disease was observed in eight patients. Hollow visceral abnormalities included: diffuse increased mucosal enhancement of both the small and large bowel (n=19); diffuse thickening of the small bowel wall (n=11); and small bowel dilatation (n=7). Solid visceral abnormalities included both decreased and or increased enhancement. Several concomitant intra- and extra-abdominal injuries were also identified. CONCLUSION: In the setting of blunt abdominal trauma, early abdominal CT can show diffuse abnormalities due to the HSC, which occasionally may alert clinicians of unsuspected shock. Recognition of these signs as distinguished from injured viscera is important in order to avoid unnecessary laparotomy. Two new signs are described: the halo sign and peripancreatic retroperitoneal fluid.

  6. Generating potentially nilpotent full sign patterns

    NARCIS (Netherlands)

    Kim, I.J.; Olesky, D.D.; Shader, B.L.; Driessche, van den P.; Holst, van der H.; Vander Meulen, K.N.

    2009-01-01

    A sign pattern is a matrix with entries in {+,-, 0}. A full sign pattern has no zero entries. The refined inertia of a matrix pattern is defined and techniques are developed for constructing potentially nilpotent full sign patterns. Such patterns are spectrally arbitrary. These techniques can also

  7. Reactor vessel decommissioning project. Final report

    International Nuclear Information System (INIS)

    Schoonen, D.H.

    1984-09-01

    This report describes a reactor vessel decommissioning project; it documents and explains the project objectives, scope, performance results, and sodium removal process. The project was successfully completed in FY-1983, within budget and without significant problems or adverse impact on the environment. Waste generated by the operation included the reactor vessel, drained sodium, and liquid, solid, and gaseous wastes which were significantly less than project estimates. Personnel radiation exposures were minimized, such that the project total was one-half the predicted exposure level. Except for the sodium removed, the material remaining in the reactor vessel is essentially the same as when the vessel arrived for processing

  8. Electrical discharge machining for vessel sample removal

    International Nuclear Information System (INIS)

    Litka, T.J.

    1993-01-01

    Due to aging-related problems or essential metallurgy information (plant-life extension or decommissioning) of nuclear plants, sample removal from vessels may be required as part of an examination. Vessel or cladding samples with cracks may be removed to determine the cause of cracking. Vessel weld samples may be removed to determine the weld metallurgy. In all cases, an engineering analysis must be done prior to sample removal to determine the vessel's integrity upon sample removal. Electrical discharge machining (EDM) is being used for in-vessel nuclear power plant vessel sampling. Machining operations in reactor coolant system (RCS) components must be accomplished while collecting machining chips that could cause damage if they become part of the flow stream. The debris from EDM is a fine talclike particulate (no chips), which can be collected by flushing and filtration

  9. LHCb: Wrong-Sign to Right-Sign Yield in Flavor Tagged $D^0 \\to K\\pi$ Data at LHCb

    CERN Multimedia

    Bessner, M

    2011-01-01

    Initial results on wrong-sign $D^0 \\rightarrow K^+ \\pi^-$ decays based on the 2010 dataset are presented: the selection criteria, the yield, the time-integrated ratio of wrong-sign to right-sign ($D^0 \\rightarrow K^- \\pi^+$) decays, and a decay time acceptance corrected ratio. The corrected ratio is measured to be $R_{acc \\, cor} = (0.409 \\pm 0.031 (stat.) \\pm 0.039 (sys.)) \\%$. This analysis is the first step towards the measurement of the time-dependent wrong-sign/right-sign ratio from which $D^0$ mixing parameters may be extracted.

  10. Nuclear power plant pressure vessels. Inservice inspections

    International Nuclear Information System (INIS)

    1995-01-01

    The requirements for the planning and reporting of inservice inspections of nuclear power plant pressure vessels are presented. The guide specifically applies to inservice inspections of Safety class 1 and 2 nuclear power plant pressure vessels, piping, pumps and valves plus their supports and reactor pressure vessel internals by non- destructive examination methods (NDE). Inservice inspections according to the Pressure Vessel Degree (549/73) are discussed separately in the guide YVL 3.0. (4 refs.)

  11. Offshore wind transport and installation vessel

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    The initial objective of the project was to complete a feasibility study to determine the viability of an innovative transportation vessel to be deployed in the installation of offshore wind farms. This included the feasibility of providing a stable-working platform that can be used in harsh offshore environments. A study of current installation contractors and their installation equipment was used to provide a preliminary specification for the installation vessel. A typical barge was selected and a number of hydrodynamic analyses were carried out in order to establish it's on course and operational stability. The analysis proved the stability of the vessel during operation was critical and that in order to utilise the crane's full potential a stabilisation system must be employed. The main aim of the work to date was to establish whether it was feasible to use a stabilisation system on the installation vessel. The spud leg FEED study established that it was feasible to use spud legs to stabilise the vessel. In order to achieve the degree of stability required it is necessary to lift the vessel completely out of the water. This was not the original aim of the study but due to the external loads on the hull it was the only viable option. Lifting the vessel out of the water results in the legs and leg casings becoming very large. This has a number of consequences for the final design. Due to large loads on the legs spud cans must be used to avoid bottom penetration, the spud cans increase the draft of the vessel by 2m. The large loads require larger winches and more reeving to be used, this results in larger pumps and motors, all of which have to be housed. The stabilisation system has been proved to be feasible for a large installation vessel, the cost and physical size are however more excessive than first anticipated. (Author)

  12. Kinematic parameters of signed verbs.

    Science.gov (United States)

    Malaia, Evie; Wilbur, Ronnie B; Milkovic, Marina

    2013-10-01

    Sign language users recruit physical properties of visual motion to convey linguistic information. Research on American Sign Language (ASL) indicates that signers systematically use kinematic features (e.g., velocity, deceleration) of dominant hand motion for distinguishing specific semantic properties of verb classes in production ( Malaia & Wilbur, 2012a) and process these distinctions as part of the phonological structure of these verb classes in comprehension ( Malaia, Ranaweera, Wilbur, & Talavage, 2012). These studies are driven by the event visibility hypothesis by Wilbur (2003), who proposed that such use of kinematic features should be universal to sign language (SL) by the grammaticalization of physics and geometry for linguistic purposes. In a prior motion capture study, Malaia and Wilbur (2012a) lent support for the event visibility hypothesis in ASL, but there has not been quantitative data from other SLs to test the generalization to other languages. The authors investigated the kinematic parameters of predicates in Croatian Sign Language ( Hrvatskom Znakovnom Jeziku [HZJ]). Kinematic features of verb signs were affected both by event structure of the predicate (semantics) and phrase position within the sentence (prosody). The data demonstrate that kinematic features of motion in HZJ verb signs are recruited to convey morphological and prosodic information. This is the first crosslinguistic motion capture confirmation that specific kinematic properties of articulator motion are grammaticalized in other SLs to express linguistic features.

  13. 46 CFR 15.405 - Familiarity with vessel characteristics.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Familiarity with vessel characteristics. 15.405 Section... MANNING REQUIREMENTS Manning Requirements; All Vessels § 15.405 Familiarity with vessel characteristics. Each credentialed individual must become familiar with the relevant characteristics of the vessel on...

  14. Estimation of center line and diameter of brain blood vessel using three-dimensional blood vessel matching method with head three-dimensional CTA image

    International Nuclear Information System (INIS)

    Maekawa, Masashi; Shinohara, Toshihiro; Nakayama, Masato; Nakasako, Noboru

    2010-01-01

    To support and automate the brain blood vessel disease diagnosis, a novel method to obtain the center line and the diameter of a blood vessel is proposed with a three-dimensional head computed tomographic angiography (CTA) image. Although the line thinning processing with distance transform or gray information is generally used to obtain the blood vessel center line, this method is not essentially one to obtain the center line and tends to yield extra lines depending on CTA images. In this study, the center line of the blood vessel is obtained by tracing the vessel. The blood vessel is traced by sequentially estimating the center point and direction of the blood vessel. The center point and direction of the blood vessel are estimated by taking the correlation between the blood vessel and a solid model of the blood vessel that is designed by considering noise influence. In addition, the vessel diameter is also estimated by correlating the blood vessel and the blood vessel model of which the diameter is variable. The validity of the proposed method is confirmed by experimentally applied the proposed method to an actual three-dimensional head CTA image. (author)

  15. Adaptation of a Vocabulary Test from British Sign Language to American Sign Language

    Science.gov (United States)

    Mann, Wolfgang; Roy, Penny; Morgan, Gary

    2016-01-01

    This study describes the adaptation process of a vocabulary knowledge test for British Sign Language (BSL) into American Sign Language (ASL) and presents results from the first round of pilot testing with 20 deaf native ASL signers. The web-based test assesses the strength of deaf children's vocabulary knowledge by means of different mappings of…

  16. Design of the ITER vacuum vessel

    International Nuclear Information System (INIS)

    Ioki, K.; Johnson, G.; Shimizu, K.; Williamson, D.

    1995-01-01

    The ITER vacuum vessel is a major safety barrier and must support electromagnetic loads during plasma disruptions and vertical displacement events (VDE) and withstand plausible accidents without losing confinement.The vacuum vessel has a double wall structure to provide structural and electrical continuity in the toroidal direction. The inner and outer shells and poloidal stiffening ribs between them are joined by welding, which gives the vessel the required mechanical strength. The space between the shells will be filled with steel balls and plate inserts to provide additional nuclear shielding. Water flowing in this space is required to remove nuclear heat deposition, which is 0.2-2.5% of the total fusion power. The minor and major radii of the tokamak are 3.9 m and 13 m respectively, and the overall height is 15 m. The total thickness of the vessel wall structure is 0.4-0.7 m.The inboard and outboard blanket segments are supported from the vacuum vessel. The support structure is required to withstand a large total vertical force of 200-300 MN due to VDE and to allow for differential thermal expansion.The first candidate for the vacuum vessel material is Inconel 625, due to its higher electric resistivity and higher yield strength, even at high temperatures. Type 316 stainless steel is also considered a vacuum vessel material candidate, owing to its large database and because it is supported by more conventional fabrication technology. (orig.)

  17. No evidence for an open vessel effect in centrifuge-based vulnerability curves of a long-vesselled liana (Vitis vinifera).

    Science.gov (United States)

    Jacobsen, Anna L; Pratt, R Brandon

    2012-06-01

    Vulnerability to cavitation curves are used to estimate xylem cavitation resistance and can be constructed using multiple techniques. It was recently suggested that a technique that relies on centrifugal force to generate negative xylem pressures may be susceptible to an open vessel artifact in long-vesselled species. Here, we used custom centrifuge rotors to measure different sample lengths of 1-yr-old stems of grapevine to examine the influence of open vessels on vulnerability curves, thus testing the hypothesized open vessel artifact. These curves were compared with a dehydration-based vulnerability curve. Although samples differed significantly in the number of open vessels, there was no difference in the vulnerability to cavitation measured on 0.14- and 0.271-m-long samples of Vitis vinifera. Dehydration and centrifuge-based curves showed a similar pattern of declining xylem-specific hydraulic conductivity (K(s)) with declining water potential. The percentage loss in hydraulic conductivity (PLC) differed between dehydration and centrifuge curves and it was determined that grapevine is susceptible to errors in estimating maximum K(s) during dehydration because of the development of vessel blockages. Our results from a long-vesselled liana do not support the open vessel artifact hypothesis. © 2012 The Authors. New Phytologist © 2012 New Phytologist Trust.

  18. Test of 6-inch-thick pressure vessels. Series 2. Intermediate test vessels V-3, V-4, and V-6

    International Nuclear Information System (INIS)

    Bryan, R.H.; Merkle, J.G.; Raftenberg, M.N.; Robinson, G.C.; Smith, J.E.

    1975-11-01

    The second series of intermediate vessel tests were crack initiation fracture tests of 6-in.-thick 39-in.-OD steel vessels with sharp surface flaws approximately 2 1 / 2 in. deep by 8 in. long in the longitudinal weld seams of the test cylinders. Fracture was initiated by means of hydraulic pressurization. One vessel was tested at each of three temperatures: 75, 130, and 190 0 F. Pretest analyses were made to predict the failure pressures and strains. Fracture toughness data obtained by equivalent-energy analysis of precracked Charpy-V tests and compact-tension specimen tests were used in the fracture analyses. The vessels behaved generally as had been expected. Posttest fracture analyses were also performed for each vessel. Detailed discussions of the fracture analysis methods developed in support of the vessel tests described are included. 34 references

  19. PWR vessel inspection performance improvements

    International Nuclear Information System (INIS)

    Blair Fairbrother, D.; Bodson, Francis

    1998-01-01

    A compact robot for ultrasonic inspection of reactor vessels has been developed that reduces setup logistics and schedule time for mandatory code inspections. Rather than installing a large structure to access the entire weld inspection area from its flange attachment, the compact robot examines welds in overlapping patches from a suction cup anchor to the shell wall. The compact robot size allows two robots to be operated in the vessel simultaneously. This significantly reduces the time required to complete the inspection. Experience to date indicates that time for vessel examinations can be reduced to fewer than four days. (author)

  20. TPX vacuum vessel transient thermal and stress conditions

    International Nuclear Information System (INIS)

    Feldshteyn, Y.; Dinkevich, S.; Feng, T.; Majumder, D.

    1995-01-01

    The TPX vacuum vessel provides the vacuum boundary for the plasma and the mechanical support for the internal components. Another function of the vacuum vessel is to contain neutron shielding water in the double wall space during normal operation. This double wall space serves as a heat reservoir for the entire vacuum vessel during bakeout. The vacuum vessel and the internal components are subjected to thermal stresses induced by a nonuniform temperature distribution within the structure during bakeout. A successful Conceptual Design Review in March 1993 has established superheated steam as the heating source of the vacuum vessel. A transient bakeout mode of the vacuum vessel and in-vessel components has been analyzed to evaluate transient period duration, proper temperature level, actual thermal stresses and performance of the steam equipment. Thermally, the vacuum vessel structure may be considered as an adiabatic system because it is perfectly insulated by the strong surrounding vacuum and multiple layers of superinsulation. Important aspects of the analysis are described herein

  1. In service inspection of SUPERPHENIX 1 vessels: MIR

    International Nuclear Information System (INIS)

    Asty, M.; Viard, J.; Lerat, B.; Saglio, R.

    1985-01-01

    Although no in-service inspection constraints were imposed on the Phenix vessels, the Safety Authorities asked that the design of SUPERPHENIX 1 makes it possible to monitor throughout the lifetime of the reactor, surface and internal defects on the main vessel. A pool design and the presence of heat baffles inside the main vessel make access from the inside of the vessel impossible. Thus, an inspection can only be performed from the outside of the main vessel: the distance between the walls of the main and safety vessels is such that an inspection device can be introduced into the corresponding space. As the design of the reactor precludes radiographic inspection, the method which was selected for monitoring internal defects in the main vessel is ultrasonics. However, the anisotropic structure of austenitic stainless steel welds limits the performance of this technique. The authors present the in-service inspection device, MIR, which has been specially developed for the visual and ultrasonic examination of SUPERPHENIX 1 vessels

  2. Extraosseous Gaucher cell deposition without adjacent bone involvement.

    Science.gov (United States)

    Meyer, Brendan J; Mills, Anne M; Gaskin, Cree M

    2014-10-01

    Extraosseous Gaucher cell deposits are a rare complication of Gaucher disease that can mimic malignancy. We describe a case of Gaucher cell deposition in the subcutaneous soft tissues overlying the lower thoracic spine in an 18-year-old woman with known type III Gaucher disease. This case is unique in the literature because this subcutaneous Gaucher mass was not associated with extension from underlying bone involvement or clear lymph node origin. It demonstrated no discernible continuity with the adjacent thoracic spinous processes, the cortices of which appeared intact. Although patients with Gaucher disease are at increased risk of malignancy, Gaucher cell deposition should remain a differential consideration for soft tissue masses with or without adjacent bone involvement in patients with known Gaucher disease.

  3. The Legal Recognition of Sign Languages

    Science.gov (United States)

    De Meulder, Maartje

    2015-01-01

    This article provides an analytical overview of the different types of explicit legal recognition of sign languages. Five categories are distinguished: constitutional recognition, recognition by means of general language legislation, recognition by means of a sign language law or act, recognition by means of a sign language law or act including…

  4. Visual cortex entrains to sign language.

    Science.gov (United States)

    Brookshire, Geoffrey; Lu, Jenny; Nusbaum, Howard C; Goldin-Meadow, Susan; Casasanto, Daniel

    2017-06-13

    Despite immense variability across languages, people can learn to understand any human language, spoken or signed. What neural mechanisms allow people to comprehend language across sensory modalities? When people listen to speech, electrophysiological oscillations in auditory cortex entrain to slow ([Formula: see text]8 Hz) fluctuations in the acoustic envelope. Entrainment to the speech envelope may reflect mechanisms specialized for auditory perception. Alternatively, flexible entrainment may be a general-purpose cortical mechanism that optimizes sensitivity to rhythmic information regardless of modality. Here, we test these proposals by examining cortical coherence to visual information in sign language. First, we develop a metric to quantify visual change over time. We find quasiperiodic fluctuations in sign language, characterized by lower frequencies than fluctuations in speech. Next, we test for entrainment of neural oscillations to visual change in sign language, using electroencephalography (EEG) in fluent speakers of American Sign Language (ASL) as they watch videos in ASL. We find significant cortical entrainment to visual oscillations in sign language sign is strongest over occipital and parietal cortex, in contrast to speech, where coherence is strongest over the auditory cortex. Nonsigners also show coherence to sign language, but entrainment at frontal sites is reduced relative to fluent signers. These results demonstrate that flexible cortical entrainment to language does not depend on neural processes that are specific to auditory speech perception. Low-frequency oscillatory entrainment may reflect a general cortical mechanism that maximizes sensitivity to informational peaks in time-varying signals.

  5. Final report for the 2nd Ex-Vessel Neutron Dosimetry Installations and Evaluations for Yonggwang Unit 2 Reactor Pressure Vessel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byoung Chul; Yoo, Choon Sung; Lee, Sam Lai; Gong, Un Sik; Choi, Kwon Jae; Chung, Kyoung Ki; Kim, Kwan Hyun; Chang, Jong Hwa; Ha, Jea Ju

    2008-01-15

    This report describes a neutron fluence assessment performed for the Yonggwang Unit 2 pressure vessel beltline region based on the guidance specified in Regulatory Guide 1.190. In this assessment, maximum fast neutron exposures expressed in terms of fast neutron fluence (E>1 MeV) and iron atom displacements (dpa) were established for the beltline region of the pressure vessel. During Cycle 16 of reactor operation, an Ex-Vessel Neutron Dosimetry Program was instituted at Yonggwang Unit 2 to provide continuous monitoring of the beltline region of the reactor vessel. The use of the Ex-Vessel Neutron Dosimetry Program coupled with available surveillance capsule measurements provides a plant specific data base that enables the evaluation of the vessel exposure and the uncertainty associated with that exposure over the service life of the unit. Ex-Vessel Neutron Dosimetry has been evaluated at the conclusion of Cycle 16.

  6. Final report for the 1st ex-vessel neutron dosimetry installations and evaluations for Kori unit 2 reactor pressure vessel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byoung Chul; Yoo, Choon Sung; Lee, Sam Lai; Chang, Kee Ok; Gong, Un Sik; Choi, Kwon Jae; Chang, Jong Hwa; Lim, Nam Jin; Hong, Joon Wha; Cheon, Byeong Jin

    2006-11-15

    This report describes a neutron fluence assessment performed for the Kori unit 2 pressure vessel belt line region based on the guidance specified in regulatory guide 1.190. In this assessment, maximum fast neutron exposures expressed in terms of fast neutron fluence (E>1 MeV) and iron atom displacements (dpa) were established for the belt line region of the pressure vessel. During cycle 20 of reactor operation, an ex-vessel neutron dosimetry program was instituted at Kori unit 2 to provide continuous monitoring of the belt line region of the reactor vessel. The use of the ex-vessel neutron dosimetry program coupled with available surveillance capsule measurements provides a plant specific data base that enables the evaluation of the vessel exposure and the uncertainty associated with that exposure over the service life of the unit. Ex-vessel neutron dosimetry has been evaluated at the conclusion of cycle 20.

  7. Final Report of the 2nd Ex-Vessel Neutron Dosimetry Installation And Evaluations for Yonggwang Unit 1 Reactor Pressure Vessel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byoung Chul; Yoo, Choon Sung; Lee, Sam Lai; Chang, Kee Ok; Gong, Un Sik; Choi, Kwon Jae; Chang, Jong Hwa; Li, Nam Jin; Hong, Joon Wha

    2007-01-15

    This report describes a neutron fluence assessment performed for the Yonggwang Unit 1 pressure vessel belt line region based on the guidance specified in Regulatory Guide 1.190. In this assessment, maximum fast neutron exposures expressed in terms of fast neutron fluence (E>1 MeV) and iron atom displacements (dpa) were established for the belt line region of the pressure vessel. During Cycle 16 of reactor operation, 2nd Ex-Vessel Neutron Dosimetry Program was instituted at Yonggwang Unit 1 to provide continuous monitoring of the belt line region of the reactor vessel. The use of the Ex-Vessel Neutron Dosimetry Program coupled with available surveillance capsule measurements provides a plant specific data base that enables the evaluation of the vessel exposure and the uncertainty associated with that exposure over the service life of the unit. Ex-Vessel Neutron Dosimetry has been evaluated at the conclusion of Cycle 16.

  8. Final Report of the 2nd Ex-Vessel Neutron Dosimetry Installation And Evaluations for Yonggwang Unit 1 Reactor Pressure Vessel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byoung Chul; Yoo, Choon Sung; Lee, Sam Lai; Gong, Un Sik; Choi, Kwon Jae; Chung, Kyoung Ki; Kim, Kwan Hyun; Chang, Jong Hwa; Ha, Jea Ju

    2008-01-15

    This report describes a neutron fluence assessment performed for the Kori Unit 2 pressure vessel belt line region based on the guidance specified in Regulatory Guide 1.190. In this assessment, maximum fast neutron exposures expressed in terms of fast neutron fluence (E>1 MeV) and iron atom displacements (dpa) were established for the belt line region of the pressure vessel. During Cycle 21 of reactor operation, an Ex-Vessel Neutron Dosimetry Program was instituted at Kori Unit 2 to provide continuous monitoring of the belt line region of the reactor vessel. The use of the Ex-Vessel Neutron Dosimetry Program coupled with available surveillance capsule measurements provides a plant specific data base that enables the evaluation of the vessel exposure and the uncertainty associated with that exposure over the service life of the unit. Ex-Vessel Neutron Dosimetry has been evaluated at the conclusion of Cycle 21.

  9. Final report for the 1st ex-vessel neutron dosimetry installation and evaluations for Kori unit 4 reactor pressure vessel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byoung Chul; Yoo, Choon Sung; Lee, Sam Lai; Chang, Kee Ok; Gong, Un Sik; Choi, Kwon Jae; Chang, Jong Hwa; Lim, Nam Jin; Hong, Joon Wha; Cheon, Byeong Jin

    2006-11-15

    This report describes a neutron fluence assessment performed for the Kori unit 4 pressure vessel belt line region based on the guidance specified in regulatory guide 1.190. In this assessment, maximum fast neutron exposures expressed in terms of fast neutron fluence (E>1 MeV) and iron atom displacements (dpa) were established for the belt line region of the pressure vessel. During cycle 16 of reactor operation, an ex-vessel neutron dosimetry program was instituted at Kori unit 4 to provide continuous monitoring of the belt line region of the reactor vessel. The use of the ex-vessel neutron dosimetry program coupled with available surveillance capsule measurements provides a plant specific data base that enables the evaluation of the vessel exposure and the uncertainty associated with that exposure over the service life of the unit. Ex-vessel neutron dosimetry has been evaluated at the conclusion of cycle 16.

  10. Instrumentation of a prestressed concrete containment vessel model

    International Nuclear Information System (INIS)

    Hessheimer, M.F.; Rightley, M.J.; Matsumoto, T.

    1995-01-01

    A series of static overpressurization tests of scale models of nuclear containment structures is being conducted by Sandia National Laboratories for the Nuclear Power Engineering Corporation of Japan and the U.S. Nuclear Regulatory Commission. At present, two tests are being planned: a test of a model of a steel containment vessel (SCV) that is representative of an improved, boiling water reactor (BWR) Mark II design; and a test of a model of a prestressed concrete containment vessel (PCCV). This paper discusses plans and the results of a preliminary investigation of the instrumentation of the PCCV model. The instrumentation suite for this model will consist of approximately 2000 channels of data to record displacements, strains in the reinforcing steel, prestressing tendons, concrete, steel liner and liner anchors, as well as pressure and temperature. The instrumentation is being designed to monitor the response of the model during prestressing operations, during Structural Integrity and Integrated Leak Rate testing, and during test to failure of the model. Particular emphasis has been placed on instrumentation of the prestressing system in order to understand the behavior of the prestressing strands at design and beyond design pressure levels. Current plans are to place load cells at both ends of one third of the tendons in addition to placing strain measurement devices along the length of selected tendons. Strain measurements will be made using conventional bonded foil resistance gages and a wire resistance gage, known as a open-quotes Tensmegclose quotes reg-sign gage, specifically designed for use with seven-wire strand. The results of preliminary tests of both types of gages, in the laboratory and in a simulated model configuration, are reported and plans for instrumentation of the model are discussed

  11. Confinement Vessel Assay System: Calibration and Certification Report

    Energy Technology Data Exchange (ETDEWEB)

    Frame, Katherine C. [Los Alamos National Laboratory; Bourne, Mark M. [Los Alamos National Laboratory; Crooks, William J. [Los Alamos National Laboratory; Evans, Louise [Los Alamos National Laboratory; Gomez, Cipriano [Retired CMR-OPS: OPERATIONS; Mayo, Douglas R. [Los Alamos National Laboratory; Miko, David K. [Los Alamos National Laboratory; Salazar, William R. [Los Alamos National Laboratory; Stange, Sy [Los Alamos National Laboratory; Vigil, Georgiana M. [Los Alamos National Laboratory

    2012-07-17

    Los Alamos National Laboratory has a number of spherical confinement vessels (CVs) remaining from tests involving nuclear materials. These vessels have an inner diameter of 6 feet with 1 to 2 inch thick steel walls. The goal of the Confinement Vessel Disposition (CVD) project is to remove debris and reduce contamination inside the vessels. The Confinement Vessel Assay System (CVAS) was developed to measure the amount of SNM in CVs before and after cleanout. Prior to cleanout, the system will be used to perform a verification measurement of each vessel. After cleanout, the system will be used to perform safeguards-quality assays of {le} 100-g {sup 239}Pu equivalent in a vessel for safeguards termination. The system was calibrated in three different mass regions (low, medium, and high) to cover the entire plutonium mass range that will be assayed. The low mass calibration and medium mass calibration were verified for material positioned in the center of an empty vessel. The systematic uncertainty due to position bias was estimated using an MCNPX model to simulate the response of the system to material localized at various points along the inner surface of the vessel. The background component due to cosmic ray spallation was determined by performing measurements of an empty vessel and comparing to measurements in the same location with no vessel present. The CVAS has been tested and calibrated in preparation for verification and safeguards measurements of CVs before and after cleanout.

  12. Confinement Vessel Assay System: Calibration and Certification Report

    International Nuclear Information System (INIS)

    Frame, Katherine C.; Bourne, Mark M.; Crooks, William J.; Evans, Louise; Gomez, Cipriano; Mayo, Douglas R.; Miko, David K.; Salazar, William R.; Stange, Sy; Vigil, Georgiana M.

    2012-01-01

    Los Alamos National Laboratory has a number of spherical confinement vessels (CVs) remaining from tests involving nuclear materials. These vessels have an inner diameter of 6 feet with 1 to 2 inch thick steel walls. The goal of the Confinement Vessel Disposition (CVD) project is to remove debris and reduce contamination inside the vessels. The Confinement Vessel Assay System (CVAS) was developed to measure the amount of SNM in CVs before and after cleanout. Prior to cleanout, the system will be used to perform a verification measurement of each vessel. After cleanout, the system will be used to perform safeguards-quality assays of (le) 100-g 239 Pu equivalent in a vessel for safeguards termination. The system was calibrated in three different mass regions (low, medium, and high) to cover the entire plutonium mass range that will be assayed. The low mass calibration and medium mass calibration were verified for material positioned in the center of an empty vessel. The systematic uncertainty due to position bias was estimated using an MCNPX model to simulate the response of the system to material localized at various points along the inner surface of the vessel. The background component due to cosmic ray spallation was determined by performing measurements of an empty vessel and comparing to measurements in the same location with no vessel present. The CVAS has been tested and calibrated in preparation for verification and safeguards measurements of CVs before and after cleanout.

  13. Analysis of factors temporarily impacting traffic sign readability

    Directory of Open Access Journals (Sweden)

    Majid Khalilikhah

    2016-10-01

    Full Text Available Traffic sign readability can be affected by the existence of dirt on traffic sign faces. However, among damaged signs, dirty traffic signs are unique since their damage is not permanent and they just can be cleaned instead of replaced. This study aimed to identify the most important factors contributing to traffic sign dirt. To do so, a large number of traffic signs in Utah were measured by deploying a vehicle instrumented with mobile LiDAR imaging and digital photolog technologies. Each individual daytime digital image was inspected for dirt. Location and climate observations obtained from official sources were compiled using ArcGIS throughout the process. To identify contributing factors to traffic sign dirt, the chi-square test was employed. To analyze the data and rank all of the factors based on their importance to the sign dirt, Random forests statistical model was utilized. After analyzing the data, it can be concluded that ground elevation, sign mount height, and air pollution had the highest effect on making traffic signs dirty. The findings of this investigation assist transportation agencies in determining traffic signs with a higher likelihood of sign dirt. In this way, agencies would schedule to clean such traffic signs more frequently.

  14. Useful radiologic sign in diagnosis of peripheral lung cancer: Nucleohalo sign and its pathologic basis

    International Nuclear Information System (INIS)

    Wang, H.; Shi, D.

    1994-01-01

    The authors investigated the x-ray findings of 117 patients with peripheral lung cancer proved by operation and pathology, of them 35(29.9%) cases were found to have the 'nucleohalo sign', 6(13.6%) in 44 cases of solitary metastatic lung cancers, but none in 167 cases of benign lung nodular lesions and 4 cases of primary lung sarcoma and lymphoma. Radiologic and pathologic correlative study of the nucleohalo sign with surgical specimens of 14 lung cancers suggested that the cancerous parenchymas in nuclear areas were more than the interstitices in 12 cases and the other 2 were equal in both parenchymas and interstitices. Instead, the cancerous parenchymas in halo areas were less than cancerous interstitices in all cases. Dynamic observation of the 'nucleohalo sign' showed that this sign was an appearance of a stage in cancer growth. It is considered a very important sign in x-ray diagnosis of peripheral lung cancer, especially in the early diagnosis of lung cancer under or equal to 3 cm in diameter

  15. Method for temporary shielding of reactor vessel internals

    International Nuclear Information System (INIS)

    Grimm, N.P.; Sejvar, J.

    1991-01-01

    This patent describes a method for shielding stored internals for reactor vessel annealing. It comprises removing nuclear fuel from the reactor vessel containment building; removing and storing upper and lower core internals under water in a refueling canal storage area; assembling a support structure in the refueling canal between the reactor vessel and the stored internals; introducing vertical shielding tanks individually through a hatch in the containment building and positioning each into the support structure; introducing horizontal shielding tanks individually through a hatch in the containment building and positioning each above the stored internals and vertical tanks; draining water from the refueling canal to the level of a flange of the reactor vessel; placing an annealing apparatus in the reactor vessel; pumping the remaining water from the reactor vessel; and annealing the reactor vessel

  16. Lymphangiography: Forgotten Tool or Rising Star in the Diagnosis and Therapy of Postoperative Lymphatic Vessel Leakage

    International Nuclear Information System (INIS)

    Kos, Sebastian; Haueisen, Harald; Lachmund, Ulrich; Roeren, Thomas

    2007-01-01

    Since the advent of computed tomography, numbers and expertise in Lymphangiography (LAG) have markedly dropped. The intention of our study was to demonstrate the persisting diagnostic and therapeutic impact of LAG on the postoperative patient with known or suspected lymphatic vessel leakage. Between May 1, 1999, and April 30, 2006, we investigated pedal lipiodol-LAGs (18 monopedal, 2 bipedal) on 22 patients (16 male, 6 female) with known or suspected postoperative chylothorax, chylaskos, lymphocele, or lymphatic fistula. Ages varied from 26 to 81 years. The spectrum of operative procedures was broad: 6 thoracic, 5 abdominal, and 11 peripheral operations were performed. In 20 patients who underwent mono- or bipedal LAG for lymphatic vessel injury, we were able to demonstrate the specific site of leakage in 15 cases (75%) and found signs of extravasation in 5 patients (25%). Furthermore, in 11 patients (55%) we were able to avoid surgery because of closure of the leak after LAG. As the conservative therapeutic approach usually takes 2-3 weeks to reveal its therapeutic effects, 73.3% (11/15) of the patients who were not reoperated before this hallmark was passed did not need any further operation. Our study clearly demonstrates that even in the decades of modern cross-sectional imaging, classic LAG is a powerful and highly reliable tool to visualize and even assist occlusion of the postoperatively damaged lymphatic vessel and may thereby avoid the need for reoperation

  17. Study on road sign recognition in LabVIEW

    Science.gov (United States)

    Panoiu, M.; Rat, C. L.; Panoiu, C.

    2016-02-01

    Road and traffic sign identification is a field of study that can be used to aid the development of in-car advisory systems. It uses computer vision and artificial intelligence to extract the road signs from outdoor images acquired by a camera in uncontrolled lighting conditions where they may be occluded by other objects, or may suffer from problems such as color fading, disorientation, variations in shape and size, etc. An automatic means of identifying traffic signs, in these conditions, can make a significant contribution to develop an Intelligent Transport Systems (ITS) that continuously monitors the driver, the vehicle, and the road. Road and traffic signs are characterized by a number of features which make them recognizable from the environment. Road signs are located in standard positions and have standard shapes, standard colors, and known pictograms. These characteristics make them suitable for image identification. Traffic sign identification covers two problems: traffic sign detection and traffic sign recognition. Traffic sign detection is meant for the accurate localization of traffic signs in the image space, while traffic sign recognition handles the labeling of such detections into specific traffic sign types or subcategories [1].

  18. Method of burying vessel containing radioactive waste

    International Nuclear Information System (INIS)

    Koga, Yoshihito.

    1989-01-01

    A float having an inert gas sealed therein is attached to a tightly closed vessel containing radioactive wastes. The vessel is inserted and kept in a small hole for burying the tightly closed vessel in an excavated shaft in rocks such as of granite or rock salts, while filling bentonite as shielding material therearound. In this case, the float is so adjusted that the apparent specific gravity is made equal or nearer between the tightly closed vessel and the bentonite, so that the rightly closed vessel does not sink and cause direct contact with the rocks even if bentonite flows due to earthquakes, etc. This can prevent radioactivity contamination through water in the rocks. (S.K.)

  19. The sign language skills classroom observation: a process for describing sign language proficiency in classroom settings.

    Science.gov (United States)

    Reeves, J B; Newell, W; Holcomb, B R; Stinson, M

    2000-10-01

    In collaboration with teachers and students at the National Technical Institute for the Deaf (NTID), the Sign Language Skills Classroom Observation (SLSCO) was designed to provide feedback to teachers on their sign language communication skills in the classroom. In the present article, the impetus and rationale for development of the SLSCO is discussed. Previous studies related to classroom signing and observation methodology are reviewed. The procedure for developing the SLSCO is then described. This procedure included (a) interviews with faculty and students at NTID, (b) identification of linguistic features of sign language important for conveying content to deaf students, (c) development of forms for recording observations of classroom signing, (d) analysis of use of the forms, (e) development of a protocol for conducting the SLSCO, and (f) piloting of the SLSCO in classrooms. The results of use of the SLSCO with NTID faculty during a trial year are summarized.

  20. Life extension of the BR2 aluminium vessel

    International Nuclear Information System (INIS)

    Koonen, E.; Fabry, A.; Chaouadi, R.; Verwerft, M.; Raedt, C. de; Winckel, S. van; Wacquier, W.; Dadoumont, J.; Verwimp, A.

    2000-01-01

    The BR2 reactor has recently undergone a major refurbishment comprising the replacement of all vessel internals. The vessel itself however was not replaced. An important requalification programme has been executed to prove that the vessel would remain fit during the contemplated life extension period of BR2. Representative material samples could be obtained from the shroud surrounding the vessel. A comprehensive in-service inspection was carried out and a vessel surveillance programme has been established. (author)

  1. Probabilistic atlas based labeling of the cerebral vessel tree

    Science.gov (United States)

    Van de Giessen, Martijn; Janssen, Jasper P.; Brouwer, Patrick A.; Reiber, Johan H. C.; Lelieveldt, Boudewijn P. F.; Dijkstra, Jouke

    2015-03-01

    Preoperative imaging of the cerebral vessel tree is essential for planning therapy on intracranial stenoses and aneurysms. Usually, a magnetic resonance angiography (MRA) or computed tomography angiography (CTA) is acquired from which the cerebral vessel tree is segmented. Accurate analysis is helped by the labeling of the cerebral vessels, but labeling is non-trivial due to anatomical topological variability and missing branches due to acquisition issues. In recent literature, labeling the cerebral vasculature around the Circle of Willis has mainly been approached as a graph-based problem. The most successful method, however, requires the definition of all possible permutations of missing vessels, which limits application to subsets of the tree and ignores spatial information about the vessel locations. This research aims to perform labeling using probabilistic atlases that model spatial vessel and label likelihoods. A cerebral vessel tree is aligned to a probabilistic atlas and subsequently each vessel is labeled by computing the maximum label likelihood per segment from label-specific atlases. The proposed method was validated on 25 segmented cerebral vessel trees. Labeling accuracies were close to 100% for large vessels, but dropped to 50-60% for small vessels that were only present in less than 50% of the set. With this work we showed that using solely spatial information of the vessel labels, vessel segments from stable vessels (>50% presence) were reliably classified. This spatial information will form the basis for a future labeling strategy with a very loose topological model.

  2. Reactor pressure vessel status report

    International Nuclear Information System (INIS)

    Strosnider, J.; Wichman, K.; Elliot, B.

    1994-12-01

    This report gives a brief description of the reactor pressure vessel (RPV), followed by a discussion of the radiation embrittlement of RPV beltline materials and the two indicators for measuring embrittlement, the end-of-license (EOL) reference temperature and the EOL upper-shelf energy. It also summarizes the GL 92-01 effort and presents, for all 37 boiling water reactor plants and 74 pressurized water reactor plants in the United States, the current status of compliance with regulatory requirements related to ensuring RPV integrity. The staff has evaluated the material data needed to predict neutron embrittlement of the reactor vessel beltline materials. These data will be stored in a computer database entitled the reactor vessel integrity database (RVID). This database will be updated annually to reflect the changes made by the licensees in future submittals and will be used by the NRC staff to assess the issues related to vessel structural integrity

  3. Repetitions in French Belgian Sign Language (LSFB) and Flemish Sign Language (VGT) narratives and conversations

    OpenAIRE

    Notarrigo, Ingrid; Meurant, Laurence; Van Herreweghe, Mieke; Vermeerbergen, Myriam

    2016-01-01

    Repetition was described in the nineties by a limited number of sign linguists: Vermeerbergen & De Vriendt (1994) looked at a small corpus of VGT data, Fisher & Janis (1990) analysed “verb sandwiches” in ASL and Pinsonneault (1994) “verb echos” in Quebec Sign Language. More recently the same phenomenon has been the focus of research in a growing number of signed languages, including American (Nunes and de Quadros 2008), Hong Kong (Sze 2008), Russian (Shamaro 2008), Polish (Flilipczak and Most...

  4. Impact of body mass index on adjacent segment disease after lumbar fusion for degenerative spine disease.

    Science.gov (United States)

    Ou, Chien-Yu; Lee, Tao-Chen; Lee, Tsung-Han; Huang, Yu-Hua

    2015-04-01

    Adjacent segment disease is an important complication after fusion of degenerative lumbar spines. However, the role of body mass index (BMI) in adjacent segment disease has been addressed less. To examine the relationship between BMI and adjacent segment disease after lumbar fusion for degenerative spine diseases. For this retrospective study, we enrolled 190 patients undergoing lumbar fusion surgery for degeneration. BMI at admission was documented. Adjacent segment disease was defined by integration of the clinical presentations and radiographic criteria based on the morphology of the dural sac on magnetic resonance images. Adjacent segment disease was identified in 13 of the 190 patients, accounting for 6.8%. The interval between surgery and diagnosis as adjacent segment disease ranged from 21 to 66 months. Five of the 13 patients required subsequent surgical intervention for clinically relevant adjacent segment disease. In the logistic regression model, BMI was a risk factor for adjacent segment disease after lumbar fusion for degenerative spine diseases (odds ratio, 1.68; 95% confidence interval, 1.27-2.21; P disease rate by 67.6%. The patients were subdivided into 2 groups based on BMI, and up to 11.9% of patients with BMI ≥ 25 kg/m were diagnosed as having adjacent segment disease at the last follow-up. BMI is a risk factor for adjacent segment disease in patients undergoing lumbar fusion for degenerative spine diseases. Because BMI is clinically objective and modifiable, controlling body weight before or after surgery may provide opportunities to reduce the rate of adjacent segment disease and to improve the outcome of fusion surgery.

  5. Developmental tumors and adjacent cortical dysplasia: single or dual pathology?

    Science.gov (United States)

    Palmini, André; Paglioli, Eliseu; Silva, Vinicius Duval

    2013-12-01

    Developmental tumors often lead to refractory partial seizures and constitute a well-defined, surgically remediable epilepsy syndrome. Dysplastic features are often associated with these tumors, and their significance carries both practical and conceptual relevance. If associated focal cortical dysplasia (FCD) relates to the extent of the epileptogenic tissue, then presurgical evaluation and surgical strategies should target both the tumor and the surrounding dyslaminated cortex. Furthermore, the association has been included in the recently revised classification of FCD and the epileptogenicity of this associated dysplastic tissue is crucial to validate such revision. In addition to the possibility of representing dual pathology, the association of developmental tumors and adjacent dysplasia may instead represent a single developmental lesion with distinct parts distributed along a histopathologic continuum. Moreover, the possibility that this adjacent dyslamination is of minor epileptogenic relevance should also be entertained. Surgical data show that complete resection of the solid tumors and immediately adjacent tissue harboring satellites may disrupt epileptogenic networks and lead to high rates of seizure freedom, challenging the epileptogenic relevance of more extensive adjacent dyslaminated cortex. Whether the latter is a primary or secondary abnormality and whether dyslaminated cortex in the context of a second lesion may produce seizures after complete resection of the main lesion is still to be proven. Wiley Periodicals, Inc. © 2013 International League Against Epilepsy.

  6. Radioactive liquid containing vessel

    International Nuclear Information System (INIS)

    Sakurada, Tetsuo; Kawamura, Hironobu.

    1993-01-01

    Cooling jackets are coiled around the outer circumference of a container vessel, and the outer circumference thereof is covered with a surrounding plate. A liquid of good conductivity (for example, water) is filled between the cooling jackets and the surrounding plate. A radioactive liquid is supplied to the container vessel passing through a supply pipe and discharged passing through a discharge pipe. Cooling water at high pressure is passed through the cooling water jackets in order to remove the heat generated from the radioactive liquid. Since cooling water at high pressure is thus passed through the coiled pipes, the wall thickness of the container vessel and the cooling water jackets can be reduced, thereby enabling to reduce the cost. Further, even if the radioactive liquid is leaked, there is no worry of contaminating cooling water, to prevent contamination. (I.N.)

  7. The pressure vessel for the NSF tandem

    International Nuclear Information System (INIS)

    Jones, C.W.

    1979-04-01

    The pressure vessel is a major component of the 30 MV tandem Van de Graaff electrostatic accelerator to be used in nuclear structure research at Daresbury Laboratory. The accelerator will be capable of accelerating the full range of ions in the form of a beam. Acceleration takes place in a vertical evacuated tube (beam tube) by means of a high potential on a terminal at the central position, the terminal and beam tube assembly being supported by an insulated stack structure within the pressure vessel. Under operating conditions the vessel is filled with sulphur hexafluoride gas (SF 6 ) at high pressure which acts as an insulating medium between the centre terminal and the vessel wall. The vessel is situated inside a concrete tower which besides supporting the injector room above the vessel also acts as radiation shielding around the accelerator. The report covers: functional requirements; fundamental considerations with regard to the design and procurement; detail design; materials; manufacture; acceptance test; surface treatment; final leak test. (U.K.)

  8. Vessel discoloration detection in malarial retinopathy

    Science.gov (United States)

    Agurto, C.; Nemeth, S.; Barriga, S.; Soliz, P.; MacCormick, I.; Taylor, T.; Harding, S.; Lewallen, S.; Joshi, V.

    2016-03-01

    Cerebral malaria (CM) is a life-threatening clinical syndrome associated with malarial infection. It affects approximately 200 million people, mostly sub-Saharan African children under five years of age. Malarial retinopathy (MR) is a condition in which lesions such as whitening and vessel discoloration that are highly specific to CM appear in the retina. Other unrelated diseases can present with symptoms similar to CM, therefore the exact nature of the clinical symptoms must be ascertained in order to avoid misdiagnosis, which can lead to inappropriate treatment and, potentially, death. In this paper we outline the first system to detect the presence of discolored vessels associated with MR as a means to improve the CM diagnosis. We modified and improved our previous vessel segmentation algorithm by incorporating the `a' channel of the CIELab color space and noise reduction. We then divided the segmented vasculature into vessel segments and extracted features at the wall and in the centerline of the segment. Finally, we used a regression classifier to sort the segments into discolored and not-discolored vessel classes. By counting the abnormal vessel segments in each image, we were able to divide the analyzed images into two groups: normal and presence of vessel discoloration due to MR. We achieved an accuracy of 85% with sensitivity of 94% and specificity of 67%. In clinical practice, this algorithm would be combined with other MR retinal pathology detection algorithms. Therefore, a high specificity can be achieved. By choosing a different operating point in the ROC curve, our system achieved sensitivity of 67% with specificity of 100%.

  9. Limiting Factors for External Reactor Vessel Cooling

    International Nuclear Information System (INIS)

    Cheung, F.B.

    2005-01-01

    The method of external reactor vessel cooling (ERVC) that involves flooding of the reactor cavity during a severe accident has been considered a viable means for in-vessel retention (IVR). For high-power reactors, however, there are some limiting factors that might adversely affect the feasibility of using ERVC as a means for IVR. In this paper, the key limiting factors for ERVC have been identified and critically discussed. These factors include the choking limit for steam venting (CLSV) through the bottleneck of the vessel/insulation structure, the critical heat flux (CHF) for downward-facing boiling on the vessel outer surface, and the two-phase flow instabilities in the natural circulation loop within the flooded cavity. To enhance ERVC, it is necessary to eliminate or relax these limiting factors. Accordingly, methods to enhance ERVC and thus improve margins for IVR have been proposed and demonstrated, using the APR1400 as an example. The strategy is based on using two distinctly different methods to enhance ERVC. One involves the use of an enhanced vessel/insulation design to facilitate steam venting through the bottleneck of the annular channel. The other involves the use of an appropriate vessel coating to promote downward-facing boiling. It is found that the use of an enhanced vessel/insulation design with bottleneck enlargement could greatly facilitate the process of steam venting through the bottleneck region as well as streamline the resulting two-phase motions in the annular channel. By selecting a suitable enhanced vessel/insulation design, not only the CLSV but also the CHF limits could be significantly increased. In addition, the problem associated with two-phase flow instabilities and flow-induced mechanical vibration could be minimized. It is also found that the use of vessel coatings made of microporous metallic layers could greatly facilitate downward-facing boiling on the vessel outer surface. With vessel coatings, the local CHF limits at

  10. Electronic structure of C28, Pa at sign C28, and U at sign C28

    International Nuclear Information System (INIS)

    Zhao, K.; Pitzer, R.M.

    1996-01-01

    Electronic structure calculations, including relativistic core potentials and the spin-orbit interaction, have been carried out on the C 28 , Pa at sign C 28 , and U at sign C 28 species. Excitation energies, spin-orbit splittings, the electron affinity, and the ionization potential are computed for C 28 . The ground state of C 28 is described well by the Hartree-Fock wave functions, but other states are not. The computed electron affinity and ionization potential are similar to those of C 60 . Strong metal-cage binding is found for Pa at sign C 28 and U at sign C 28 , similar to that in U(C 8 H 8 ) 2 . The ground electronic states depend on the order of the lowest-energy cage π * and metal 5f orbitals, with (π * ) 1 and (π * ) 1 (5f) 1 found to be the ground electronic configurations for the two complexes. U at sign C 28 is found to be diamagnetic. 30 refs., 1 fig., 13 tabs

  11. Proactive life extension of pressure vessels

    Science.gov (United States)

    Mager, Lloyd

    1998-03-01

    For a company to maintain its competitive edge in today's global market every opportunity to gain an advantage must be exploited. Many companies are strategically focusing on improved utilization of existing equipment as well as regulatory compliance. Abbott Laboratories is no exception. Pharmaceutical companies such as Abbott Laboratories realize that reliability and availability of their production equipment is critical to be successful and competitive. Abbott Laboratories, like many of our competitors, is working to improve safety, minimize downtime and maximize the productivity and efficiency of key production equipment such as the pressure vessels utilized in our processes. The correct strategy in obtaining these objectives is to perform meaningful inspection with prioritization based on hazard analysis and risk. The inspection data gathered in Abbott Laboratories pressure vessel program allows informed decisions leading to improved process control. The results of the program are reduced risks to the corporation and employees when operating pressure retaining equipment. Accurate and meaningful inspection methods become the cornerstone of a program allowing proper preventative maintenance actions to occur. Successful preventative/predictive maintenance programs must utilize meaningful nondestructive evaluation techniques and inspection methods. Nondestructive examination methods require accurate useful tools that allow rapid inspection for the entire pressure vessel. Results from the examination must allow the owner to prove compliance of all applicable regulatory laws and codes. At Abbott Laboratories the use of advanced NDE techniques, primarily B-scan ultrasonics, has provided us with the proper tools allowing us to obtain our objectives. Abbott Laboratories uses B-scan ultrasonics utilizing a pulse echo pitch catch technique to provide essential data on our pressure vessels. Equipment downtime is reduced because the nondestructive examination usually takes

  12. Determinants of injuries in passenger vessel accidents.

    Science.gov (United States)

    Yip, Tsz Leung; Jin, Di; Talley, Wayne K

    2015-09-01

    This paper investigates determinants of crew and passenger injuries in passenger vessel accidents. Crew and passenger injury equations are estimated for ferry, ocean cruise, and river cruise vessel accidents, utilizing detailed data of individual vessel accidents that were investigated by the U.S. Coast Guard during the time period 2001-2008. The estimation results provide empirical evidence (for the first time in the literature) that crew injuries are determinants of passenger injuries in passenger vessel accidents. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Improved nuclear reactor construction with bottom supported reactor vessel

    International Nuclear Information System (INIS)

    Sharbaugh, J.E.

    1987-01-01

    An improved liquid metal nuclear reactor construction has a reactor core and a generally cylindrical reactor vessel for holding liquid metal coolant and housing the core within the pool. A generally cylindrical concrete containment structure surrounds the reactor vessel and a central support pedestal is anchored to the containment structure base mat and supports the bottom wall of the reactor vessel and the reactor core. The periphery of the reactor vessel bore is supported by an annular structure which allows thermal expansion but not seismic motion of the vessel, and a bed of thermally insulating material uniformly supports the vessel base whilst allowing expansion thereof. A guard ring prevents lateral seismic motion of the upper end of the reactor vessel. The periphery of the core is supported by an annular structure supported by the vessel base and keyed to the vessel wall so as to be able to expand but not undergo seismic motion. A deck is supported on the containment structure above the reactor vessel open top by annular bellows, the deck carrying the reactor control rods such that heating of the reactor vessel results in upward expansion against the control rods. (author)

  14. Benign Lesions in Mucosa Adjacent to Intestinal-Type Sinonasal Adenocarcinoma

    Directory of Open Access Journals (Sweden)

    Blanca Vivanco

    2011-01-01

    Full Text Available Occupational exposure to wood dust is a strong risk factor for the development of intestinal-type sinonasal adenocarcinoma (ITAC; however, knowledge on possible precursor lesions or biomarkers is limited. Fifty-one samples of tumor-adjacent mucosa and 19 control samples of mucosa from the unaffected fossa of ITAC patients were evaluated for histological changes and p53 protein expression. Mild dysplasia was observed in 14%, cuboidal metaplasia in 57%, intestinal metaplasia in 8%, squamous metaplasia in 24%, and cylindrocellular hyperplasia in 53% of cases. P53 immunopositivity was generally weak occurring most frequently in squamous metaplasia. Wood dust etiology did not appear of influence on the histological changes, but p53 showed a tendency for higher positivity. Dysplasia adjacent to tumor was indicative of subsequent development of recurrence. In conclusion, precursor lesions do occur in mucosa adjacent to ITAC. This is clinically important, because it may justify the screening of high-risk individuals such as woodworkers.

  15. Eigen-Gradients for Traffic Sign Recognition

    Directory of Open Access Journals (Sweden)

    Sheila Esmeralda Gonzalez-Reyna

    2013-01-01

    Full Text Available Traffic sign detection and recognition systems include a variety of applications like autonomous driving, road sign inventory, and driver support systems. Machine learning algorithms provide useful tools for traffic sign identification tasks. However, classification algorithms depend on the preprocessing stage to obtain high accuracy rates. This paper proposes a road sign characterization method based on oriented gradient maps and the Karhunen-Loeve transform in order to improve classification performance. Dimensionality reduction may be important for portable applications on resource constrained devices like FPGAs; therefore, our approach focuses on achieving a good classification accuracy by using a reduced amount of attributes compared to some state-of-the-art methods. The proposed method was tested using German Traffic Sign Recognition Benchmark, reaching a dimensionality reduction of 99.3% and a classification accuracy of 95.9% with a Multi-Layer Perceptron.

  16. Final processing vessel for radioactive waste

    International Nuclear Information System (INIS)

    Tejima, Takaya; Hiraki, Akimitsu.

    1989-01-01

    An inorganic inner layer comprising dense inorganic material such as organic polymer-impregnated concretes is formed to about 10 - 50 mm in average thickness at the inside of a metal vessel. Further, the surface of the vessel is formed as a flat surface with no or only small reinforcing protrusions. Thus, if the final processing vessel should be dropped during transportation or handling by mistake, since impact shocks do not concentrate to protrusions as usual, no local stress concentration occurs to the inorganic inner liner layer. Accordingly, the risk of rapture can be reduced greatly. Further, since impact shock resistance layer put between the metal vessel and the inorganic inner liner layer absorbs shocks, a further sufficient strength can be obtained against dropping accident. (T.M.)

  17. 33 CFR 88.11 - Law enforcement vessels.

    Science.gov (United States)

    2010-07-01

    ... NAVIGATION RULES ANNEX V: PILOT RULES § 88.11 Law enforcement vessels. (a) Law enforcement vessels may display a flashing blue light when engaged in direct law enforcement or public safety activities. This... lights. (b) The blue light described in this section may be displayed by law enforcement vessels of the...

  18. 2013 EPA Vessels General Permit (VGP)

    Data.gov (United States)

    U.S. Environmental Protection Agency — Information for any vessel that submitted a Notice of Intent (NOI), Notice of Termination (NOT), or annual report under EPA's 2013 Vessel General Permit (VGP)....

  19. EDS V25 containment vessel explosive qualification test report.

    Energy Technology Data Exchange (ETDEWEB)

    Rudolphi, John Joseph

    2012-04-01

    The V25 containment vessel was procured by the Project Manager, Non-Stockpile Chemical Materiel (PMNSCM) as a replacement vessel for use on the P2 Explosive Destruction Systems. It is the first EDS vessel to be fabricated under Code Case 2564 of the ASME Boiler and Pressure Vessel Code, which provides rules for the design of impulsively loaded vessels. The explosive rating for the vessel based on the Code Case is nine (9) pounds TNT-equivalent for up to 637 detonations. This limit is an increase from the 4.8 pounds TNT-equivalency rating for previous vessels. This report describes the explosive qualification tests that were performed in the vessel as part of the process for qualifying the vessel for explosive use. The tests consisted of a 11.25 pound TNT equivalent bare charge detonation followed by a 9 pound TNT equivalent detonation.

  20. Approaching Sign Language Test Construction: Adaptation of the German Sign Language Receptive Skills Test

    Science.gov (United States)

    Haug, Tobias

    2011-01-01

    There is a current need for reliable and valid test instruments in different countries in order to monitor deaf children's sign language acquisition. However, very few tests are commercially available that offer strong evidence for their psychometric properties. A German Sign Language (DGS) test focusing on linguistic structures that are acquired…

  1. The role of syllables in sign language production.

    Science.gov (United States)

    Baus, Cristina; Gutiérrez, Eva; Carreiras, Manuel

    2014-01-01

    The aim of the present study was to investigate the functional role of syllables in sign language and how the different phonological combinations influence sign production. Moreover, the influence of age of acquisition was evaluated. Deaf signers (native and non-native) of Catalan Signed Language (LSC) were asked in a picture-sign interference task to sign picture names while ignoring distractor-signs with which they shared two phonological parameters (out of three of the main sign parameters: Location, Movement, and Handshape). The results revealed a different impact of the three phonological combinations. While no effect was observed for the phonological combination Handshape-Location, the combination Handshape-Movement slowed down signing latencies, but only in the non-native group. A facilitatory effect was observed for both groups when pictures and distractors shared Location-Movement. Importantly, linguistic models have considered this phonological combination to be a privileged unit in the composition of signs, as syllables are in spoken languages. Thus, our results support the functional role of syllable units during phonological articulation in sign language production.

  2. Guidelines for pressure vessel safety assessment

    Science.gov (United States)

    Yukawa, S.

    1990-04-01

    A technical overview and information on metallic pressure containment vessels and tanks is given. The intent is to provide Occupational Safety and Health Administration (OSHA) personnel and other persons with information to assist in the evaluation of the safety of operating pressure vessels and low pressure storage tanks. The scope is limited to general industrial application vessels and tanks constructed of carbon or low alloy steels and used at temperatures between -75 and 315 C (-100 and 600 F). Information on design codes, materials, fabrication processes, inspection and testing applicable to the vessels and tanks are presented. The majority of the vessels and tanks are made to the rules and requirements of ASME Code Section VIII or API Standard 620. The causes of deterioration and damage in operation are described and methods and capabilities of detecting serious damage and cracking are discussed. Guidelines and recommendations formulated by various groups to inspect for the damages being found and to mitigate the causes and effects of the problems are presented.

  3. Community conservation adjacent to Ruaha National Park, Tanzania

    Science.gov (United States)

    Sue Stolberger

    2007-01-01

    In the areas adjacent to Ruaha National Park where rural communities exist, much more work and education is required to enable them to benefit directly and indirectly from tourism and managing their own natural resources.

  4. Model tests for prestressed concrete pressure vessels

    International Nuclear Information System (INIS)

    Stoever, R.

    1975-01-01

    Investigations with models of reactor pressure vessels are used to check results of three dimensional calculation methods and to predict the behaviour of the prototype. Model tests with 1:50 elastic pressure vessel models and with a 1:5 prestressed concrete pressure vessel are described and experimental results are presented. (orig.) [de

  5. Development of automatic ultrasonic testing equipment for reactor pressure vessel

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Kee Ok; Park, Dae Yung; Park, Moon Hoh; Koo, Kil Mo; Park, Kwang Heui; Kang, Sang Sin; Bang, Heui Song; Noh, Heui Choong; Kong, Woon Sik [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1994-08-01

    The selected weld areas of reactor pressure vessel and adjacent piping are examined by remote mechanized ultrasonic testing(MUT) equipment. Since the MUT equipment was purchased from Southwest Research Institute (SwRI) in April 1985, we have performed 15 inservice inspections and 5 preservice inspections. However, the reliability of examination was recently decreased rapidly as the problems which results from the old age of equipment and the frequent movement to plant site to site have occurred frequently. Therefore, the 3-axis control system hardware in occurring many problems among the equipments of mechanized ultrasonic testing (MUT) was designed and developed to cover the examination areas of nozzle-shell weld as specified in ASME Code Section XI and to improve the examination reliability. The new 3-axis control system hardware with the performance of this project was developed to be compatible with the old one and it was used as dual system or spare parts of the old system. Furthermore, the established technologies are expected to be applied to the similar control systems in nuclear power plant. 17 figs, 2 pix, 2 tabs, 10 refs. (Author).

  6. Development of automatic ultrasonic testing equipment for reactor pressure vessel

    International Nuclear Information System (INIS)

    Jang, Kee Ok; Park, Dae Yung; Park, Moon Hoh; Koo, Kil Mo; Park, Kwang Heui; Kang, Sang Sin; Bang, Heui Song; Noh, Heui Choong; Kong, Woon Sik

    1994-08-01

    The selected weld areas of reactor pressure vessel and adjacent piping are examined by remote mechanized ultrasonic testing(MUT) equipment. Since the MUT equipment was purchased from Southwest Research Institute (SwRI) in April 1985, we have performed 15 inservice inspections and 5 preservice inspections. However, the reliability of examination was recently decreased rapidly as the problems which results from the old age of equipment and the frequent movement to plant site to site have occurred frequently. Therefore, the 3-axis control system hardware in occurring many problems among the equipments of mechanized ultrasonic testing (MUT) was designed and developed to cover the examination areas of nozzle-shell weld as specified in ASME Code Section XI and to improve the examination reliability. The new 3-axis control system hardware with the performance of this project was developed to be compatible with the old one and it was used as dual system or spare parts of the old system. Furthermore, the established technologies are expected to be applied to the similar control systems in nuclear power plant. 17 figs, 2 pix, 2 tabs, 10 refs. (Author)

  7. Integrated sign management system : ADOT maintenance group

    Science.gov (United States)

    2003-12-01

    The Arizona Department of Transportation (ADOT) maintains and manages an inventory of roadway signs. Before the implementation of this project, sign technicians maintained inventory records on individual laptops to track their daily sign maintenance ...

  8. Crack propagation on spherical pressure vessels

    International Nuclear Information System (INIS)

    Lebey, J.; Roche, R.

    1975-01-01

    The risk presented by a crack on a pressure vessel built with a ductile steel cannot be well evaluated by simple application of the rules of Linear Elastic Fracture Mechanics, which only apply to brittle materials. Tests were carried out on spherical vessels of three different scales built with the same steel. Cracks of different length were machined through the vessel wall. From the results obtained, crack initiation stress (beginning of stable propagation) and instable propagation stress may be plotted against the lengths of these cracks. For small and medium size, subject to ductile fracture, the resulting curves are identical, and may be used for ductile fracture prediction. Brittle rupture was observed on larger vessels and crack propagation occurred at lower stress level. Preceedings curves are not usable for fracture analysis. Ultimate pressure can be computed with a good accuracy by using equivalent energy toughness, Ksub(1cd), characteristic of the metal plates. Satisfactory measurements have been obtained on thin samples. The risks of brittle fracture may then judged by comparing Ksub(1cd) with the calculated K 1 value, in which corrections for vessel shape are taken into account. It is thus possible to establish the bursting pressure of cracked spherical vessels, with the help of two rules, one for brittle fracture, the other for ductile instability. A practical method is proposed on the basis of the work reported here

  9. Sealing method and sealing device for radioactive waste containing vessel

    International Nuclear Information System (INIS)

    Ishiwatari, Koji; Otsuki, Akira

    1998-01-01

    A radioactive waste-containing body is hoisted down into a strong-material vessel opened upwardly, and a strong-material lid is hoisted down to the opening of the strong-material-vessel and welded. The strong material vessel is hoisted up and loaded on a corrosion resistant-material bottom plate placed horizontally. A corrosion resistant-material vessel having one opening end and having a corrosion resistant-material flange on the other end and previously agreed with the strong material-vessel main body is hoisted up by a hoisting device having an inserting device so that the opening of the corrosion resistant vessel is directed downwardly. The corrosion resistant vessel is press-fitted to the outside of the strong material-vessel by the inserting device while being heated by a preheater to shrink. Subsequently, the lower end of the corrosion resistant-material vessel and the corrosion resistant-material bottom plate are welded to constitute a corrosion resistant-material vessel. Then, the radioactive waste containing body can be sealed in a sealing vessel comprising the strong-material vessel and the corrosion resistant-material vessel. (N.H.)

  10. Bone marrow blood vessels: normal and neoplastic niche

    Directory of Open Access Journals (Sweden)

    Saeid Shahrabi

    2016-11-01

    Full Text Available Blood vessels are among the most important factors in the transport of materials such as nutrients and oxygen. This study will review the role of blood vessels in normal bone marrow hematopoiesis as well as pathological conditions like leukemia and metastasis. Relevant literature was identified by a Pubmed search (1992-2016 of English-language papers using the terms bone marrow, leukemia, metastasis, and vessel. Given that blood vessels are conduits for the transfer of nutrients, they create a favorable situation for cancer cells and cause their growth and development. On the other hand, blood vessels protect leukemia cells against chemotherapy drugs. Finally, it may be concluded that the vessels are an important factor in the development of malignant diseases.

  11. Uplink scheduling and adjacent-channel coupling loss analysis for TD-LTE deployment.

    Science.gov (United States)

    Yeo, Woon-Young; Moon, Sung Ho; Kim, Jae-Hoon

    2014-01-01

    TD-LTE, one of the two duplexing modes in LTE, operates in unpaired spectrum and has the advantages of TDD-based technologies. It is expected that TD-LTE will be more rapidly deployed in near future and most of WiMax operators will upgrade their networks to TD-LTE gradually. Before completely upgrading to TD-LTE, WiMax may coexist with TD-LTE in an adjacent frequency band. In addition, multiple TD-LTE operators may deploy their networks in adjacent bands. When more than one TDD network operates in adjacent frequency bands, severe interference may happen due to adjacent channel interference (ACI) and unsynchronized operations. In this paper, coexistence issues between TD-LTE and other systems are analyzed and coexistence requirements are provided. This paper has three research objectives. First, frame synchronization between TD-LTE and WiMax is discussed by investigating possible combinations of TD-LTE and WiMax configurations. Second, an uplink scheduling algorithm is proposed to utilize a leakage pattern of ACI in synchronized operations. Third, minimum requirements for coexistence in unsynchronized operations are analyzed by introducing a concept of adjacent-channel coupling loss. From the analysis and simulation results, we can see that coexistence of TD-LTE with other TDD systems is feasible if the two networks are synchronized. For the unsynchronized case, some special cell-site engineering techniques may be required to reduce the ACI.

  12. Vessel calibration for accurate material accountancy at RRP

    International Nuclear Information System (INIS)

    Yanagisawa, Yuu; Ono, Sawako; Iwamoto, Tomonori

    2004-01-01

    RRP has a 800t·Upr capacity a year to re-process, where would be handled a large amount of nuclear materials as solution. A large scale plant like RRP will require accurate materials accountancy system, so that the vessel calibration with high-precision is very important as initial vessel calibration before operation. In order to obtain the calibration curve, it is needed well-known each the increment volume related with liquid height. Then we performed at least 2 or 3 times run with water for vessel calibration and careful evaluation for the calibration data should be needed. We performed vessel calibration overall 210 vessels, and the calibration of 81 vessels including IAT and OAT were held under presence of JSGO and IAEA inspectors taking into account importance on the material accountancy. This paper describes outline of the initial vessel calibration and calibration results based on back pressure measurement with dip tubes. (author)

  13. 46 CFR 90.10-16 - Industrial vessel.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Industrial vessel. 90.10-16 Section 90.10-16 Shipping... PROVISIONS Definition of Terms Used in This Subchapter § 90.10-16 Industrial vessel. This term means every vessel which by reason of its special outfit, purpose, design, or function engages in certain industrial...

  14. Equipment for decontamination of inner vessel surfaces featuring sound or ultrasound transducer on float inside liquid-filled vessel

    International Nuclear Information System (INIS)

    Bar, J.; Straka, M.

    1982-01-01

    The equipment for the decontamination of the inner surfaces of vessels consists of an immersion float which is provided with a screw, an electric motor, a rudder and at least one float chamber, and a remotely controlled valve. The float is provided with a power source, a high frequency a.c. current generator and a control panel outside the vessel. The float is connected to parts of the equipment outside the vessel by a multi-core cable. The immersion float may also be provided with a detector for measuring the quantity of ionizing radiation whose display is placed outside the vessel being decontaminated. (B.S.)

  15. Discharge of Non-Reactive Fluids from Vessels

    Directory of Open Access Journals (Sweden)

    M. Castier

    Full Text Available Abstract This paper presents simulations of discharges from pressure vessels that consistently account for non-ideal fluid behavior in all the required thermodynamic properties and individually considers all the chemical components present. The underlying assumption is that phase equilibrium occurs instantaneously inside the vessel and, thus, the dynamics of the fluid in the vessel comprises a sequence of equilibrium states. The formulation leads to a system of differential-algebraic equations in which the component mass balances and the energy balance are ordinary differential equations. The algebraic equations account for the phase equilibrium conditions inside the vessel and at the discharge point, and for sound speed calculations. The simulator allows detailed predictions of the condition inside the vessel and at the discharge point as a function of time, including the flow rate and composition of the discharge. The paper presents conceptual applications of the simulator to predict the effect of leaks from vessels containing mixtures of light gases and/or hydrocarbons and comparisons to experimental data.

  16. Pressure vessel integrity and weld inspection procedure

    International Nuclear Information System (INIS)

    Solomon, K.A.; Okrent, D.; Kastenberg, W.E.

    1975-01-01

    The primary objective of this paper is to develop a simple methodology which, when coupled with existing observations on pressure vessel behavior, provides an inter-relation between pressure vessel integrity, and the parameters of the in-service inspection program, including inspection sample size, frequency and efficiency. A modified Markov process is employed and a computer code was written to obtain numerical results. The Markov process mathematically describes the following physical events. In a nuclear reactor pressure vessel weld, some defects may exist prior to the zeroth inspection (i.e., prior to vessel operation). During the zeroth inspection and repair processes, some of these defects are removed. During the first cycle of vessel operation, the existing defects may grow and some new defects may be generated. Those defects that are found at the first (and succeeding) inspection interval and warrant repair, are repaired. The above process continues through several operating cycles to the end of vessel life. During any inspection, only a portion of the welds may be inspected, and with less than perfect efficiency

  17. Ultrasonographic, endoscopic and histological appearances of the caecum in cats presenting with chronic clinical signs of caecocolic disease.

    Science.gov (United States)

    Hahn, Harriet; Pey, Pascaline; Baril, Aurélie; Charpentier, Julie; Desquilbet, Loic; Le Poder, Sophie; Château-Joubert, Sophie; Laloy, Eve; Freiche, Valerie

    2017-02-01

    Objectives This study aimed to describe the ultrasonographic, endoscopic and histological characteristics of the caecum and ileocaecocolic junction in cats suffering from chronic clinical signs compatible with caecocolic disease. Methods Cats presenting with clinical signs suggestive of a caecocolic disease were prospectively recruited. All cats underwent an ultrasonographic examination of the caecum, ileum, colon, ileocolic lymph nodes and local mesenteric fat, in addition to comprehensive abdominal ultrasonography. This was followed by a colonoscopy with a macroscopic assessment of the caecocolic mucosa; caecocolic tissue samples were systematically collected for histologic analysis. Results Eighteen cats were included. Eleven of 18 cats had ultrasonographic abnormalities adjacent to the ileocaecocolic junction (lymphadenopathy, local steatitis) and 13/18 cats had abnormalities directly related to the junction (wall thickening, loss of wall layering). Seventeen of 18 cats had at least one ultrasonographic abnormality. Endoscopically, hyperaemia, oedema, discoloration and/or erosions were found in all cats. Each cat was classified as having mild or moderate-to-severe lesions according to endoscopic results; no classification could be established statistically for ultrasonographic results. The accentuation of the dimpled pattern tended to be inversely related to the severity of endoscopic lesion scoring. Histologically, a large proportion of cats showed typhlitis (13/16), one had lymphoma and two were normal. All cats with typhlitis also had colitis. There was only slight agreement between endoscopic and histological caecal results regarding the severity of lesions. Loss of caecal wall layering on ultrasound was found in 7/18 cats and, surprisingly, did not appear as a reliable predictor of the severity of inflammation or of malignancy; neither did local steatitis nor lymph node size. Conclusions and relevance Ultrasonography and endoscopy should not be used as the

  18. Segmentation of British Sign Language (BSL): Mind the gap!

    OpenAIRE

    Orfanidou, E.; McQueen, J.; Adam, R.; Morgan, G.

    2015-01-01

    This study asks how users of British Sign Language (BSL) recognize individual signs in connected sign sequences. We examined whether this is achieved through modality-specific or modality-general segmentation procedures. A modality-specific feature of signed languages is that, during continuous signing, there are salient transitions between sign locations. We used the sign-spotting task to ask if and how BSL signers use these transitions in segmentation. A total of 96 real BSL signs were prec...

  19. Bone marrow changes adjacent to the sacroiliac joints after pelvic radiotherapy mimicking metastases on MRI

    Energy Technology Data Exchange (ETDEWEB)

    Kanberoglu, K.; Mihmanli, I.; Kurugoglu, S.; Ogut, G.; Kantarci, F. [Dept. of Radiology, Istanbul Univ. (Turkey)

    2001-09-01

    Radiation-induced changes in the sacroiliac joints mimicking metastases on MR images were evaluated. Twelve patients who received radiotherapy to the pelvic region due to pelvic malignancy were included in the study. All patients had undergone external beam radiation therapy to the pelvic region, and 2 patients received supplementary internal radiation. The changes in the sacroiliac joints were evaluated. Computed-tomography-guided core bone biopsy from the bone marrow was taken from their corresponding MR sections in 5 of the patients. T1 hypointense and T2 hyperintense areas with ill-defined margins in the bone marrow adjacent to the sacroiliac joints were observed in all patients. On bone scintigraphy all the lesions demonstrated increased activity. Other radiological modalities excluded fracture, soft tissue mass, and osseous destruction. Bone biopsies demonstrated peritrabecular fibrosis and inflammatory cell infiltration. Patients receiving radiotherapy to the pelvis may demonstrate T1 hypointense/T2 hyperintense, ill-defined postradiotherapeutic benign changes in the sacroiliac joints. In the absence of any other signs of disease progression and when the imaging pattern is typical, close radiological follow-up should be sufficient to rule out metastases. (orig.)

  20. Nuclear power plant pressure vessels. Control of piping

    International Nuclear Information System (INIS)

    2000-01-01

    The guide presents requirements for the pipework of nuclear facilities in Finland. According to the section 117 of the Finnish Nuclear Energy Degree (161/88), the Radiation and Nuclear Safety Authority of Finland (STUK) controls the pressure vessels of nuclear facilities in accordance with the Nuclear Energy Act (990/87) and, to the extent applicable in accordance with the Act of Pressure Vessels (98/73) and the rules and regulations issued by the virtue of these. In addition STUK is an inspecting authority of pressure vessels of nuclear facilities in accordance with the Pressure Vessel Degree (549/1973). According to the section of the Pressure Vessel Degree, a pressure vessel is a steam boiler, pressure container, pipework of other such appliance in which the pressure is above or may come to exceed the atmospheric pressure. Guide YVL 3.0 describes in general terms how STUK controls pressure vessels. STUK controls Safety Class 1, 2 and 3 piping as well as Class EYT (non-nuclear) and their support structures in accordance with this guide and applies the provisions of the Decision of the Ministry of Trade and Industry on piping (71/1975) issued by virtue of the Pressure Vessel Decree

  1. Electronic traffic signs: The interplay between hybrid and full matrix e-signs

    Energy Technology Data Exchange (ETDEWEB)

    Lucas-Alba, A.; Hernando Mazon, A.; Blanch Mico, A.M.; Gutierrez Perez, D.; Echeverria Villaspi, J.I.; Landa Tejero-Garces, N.

    2016-07-01

    Road signs constitute a complex and growing communication system where different elements (pictograms, shapes, texts, etc.) are combined following different strategies. In this paper we have confronted drivers with a number of messages (congestion or road works, before, between, after location/s) developed as an adaptation of Advance Location Signs (class G, 1c in the 1968 Convention) to electronic displays. We manipulate two main factors a) the reading strategy (top-down vs. bottom-up) and the type of matrix display (hybrid, dissociating pictogram and text, vs. full matrix), in a repeated measures experimental design. The time taken to answer and the response given (correct, incorrect) was measured for each of the 24 message-blocks. Results show that the organization of the elements displayed is a key determinant for driver comprehension. Further thoughts on the need to understand the interplay between the formats adopted by static vs electronic message signs are provided. (Author)

  2. Sacroiliac Joint Fusion Minimally Affects Adjacent Lumbar Segment Motion: A Finite Element Study.

    Science.gov (United States)

    Lindsey, Derek P; Kiapour, Ali; Yerby, Scott A; Goel, Vijay K

    2015-01-01

    Adjacent segment disease is a recognized consequence of fusion in the spinal column. Fusion of the sacroiliac joint is an effective method of pain reduction. Although effective, the consequences of sacroiliac joint fusion and the potential for adjacent segment disease for the adjacent lumbar spinal levels is unknown. The objective of this study was to quantify the change in range of motion of the sacroiliac joint and the adjacent lumbar spinal motion segments due to sacroiliac joint fusion and compare these changes to previous literature to assess the potential for adjacent segment disease in the lumbar spine. An experimentally validated finite element model of the lumbar spine and pelvis was used to simulate a fusion of the sacroiliac joint using three laterally placed triangular implants (iFuse Implant System, SI-BONE, Inc., San Jose, CA). The range of motion of the sacroiliac joint and the adjacent lumbar spinal motion segments were calculated using a hybrid loading protocol and compared with the intact range of motion in flexion, extension, lateral bending, and axial rotation. The range of motions of the treated sacroiliac joints were reduced in flexion, extension, lateral bending, and axial rotation, by 56.6%, 59.5%, 27.8%, and 53.3%, respectively when compared with the intact condition. The stiffening of the sacroiliac joint resulted in increases at the adjacent lumbar motion segment (L5-S1) for flexion, extension, lateral bending, and axial rotation, of 3.0%, 3.7%, 1.1%, and 4.6%, respectively. Fusion of the sacroiliac joint resulted in substantial (> 50%) reductions in flexion, extension, and axial rotation of the sacroiliac joint with minimal (sacroiliac joint fusion, the long-term clinical results remain to be investigated.

  3. Fast-neutron nuclear reactor vessel

    International Nuclear Information System (INIS)

    Presciuttini, L.

    1984-01-01

    The reactor vessel comprises a cylindrical shell, of which axis is vertical, coupled at its lower part with a dished bottom. The reactor core rests on a support plate bearing on the bottom of the vessel. The above dished bottom comprises a spherical sector having the same radius and the same axis as the cylindrical shell and joining the lower part of the shell, and a spherical head of which radius is a little more important than the spherical sector one. A cylindrical support for the reactor core is attached to the vessel at the joint between the two dished sections. The invention applies more particularly to integrated type reactors cooled by liquid sodium [fr

  4. Analysis of CD83 antigen expression in human breast fibroadenoma and adjacent tissue

    Directory of Open Access Journals (Sweden)

    Marcus Nascimento Borges

    Full Text Available CONTEXT AND OBJECTIVE: Dendritic cell maturation is considered essential for starting an immune response. The CD83 antigen is an important marker of dendritic cell maturation. The objectives here were to analyze CD83 antigen expression in human breast fibroadenoma and breast tissue adjacent to the lesion and to identify clinical factors that might influence this expression. DESIGN AND SETTING: This was a retrospective study at a public university hospital, in which 29 histopathological samples of breast fibroadenoma and adjacent breast tissue, from 28 women of reproductive age, were analyzed. METHODS: The immunohistochemistry method was used to analyze the cell expression of the antigen. The antigen expression in the cells was evaluated by means of random manual counting using an optical microscope. RESULTS: Positive expression of the CD83 antigen in the epithelial cells of the fibroadenoma (365.52; standard deviation ± 133.13 in relation to the adjacent breast tissue cells (189.59; standard deviation ± 140.75 was statistically larger (P < 0.001. Several clinical features were analyzed, but only parity was shown to influence CD83 antigen expression in the adjacent breast tissue, such that positive expression was more evident in nulliparous women (P = 0.042. CONCLUSIONS: The expression of the CD83 antigen in the fibroadenoma was positive and greater than in the adjacent breast tissue. Positive expression of the antigen in the adjacent breast tissue was influenced by parity, and was significantly more evident in nulliparous women.

  5. Risk Factors for the Development of Adjacent Segment Disease Following Anterior Cervical Arthrodesis

    Directory of Open Access Journals (Sweden)

    Ezgi Akar

    2015-06-01

    Full Text Available Aim: The aim of this study was to clinically and radiologically evaluate the efficacy of anterior cervical discectomy and fusion (ACDF in the treatment of adjacent level degeneration. Methods: We retrospectively evaluated 89 patients (55 females, 34 males who underwent ACDF. Adjacent segment degeneration findings were evaluated by investigating new osteophyte formation, growth of existing osteophytes, ossification of the anterior longitudinal ligament, presence of intervertebral disc space narrowing, sagittal alignment and range of motion (ROM using serial radiographs and magnetic resonance imaging. Results: The mean age of the 89 patients was 41.3 (24-76 years. The mean follow-up duration was 34.3 (12-64 months. Radiographic evidence of adjacent segment degeneration was observed in 12 patients (13.4%. Nine (75% patients had new complaints. Of the patients who had degenerative changes, 7 were (58% were male, 5 (42% were female; the mean age was 46 (30- 62 years. It was observed that the level of fusion and the number of fusion did not increase the adjacent segment degeneration. All of 12 patients were observed to have a non lordotic cervical spine and increased ROM. Conclusion: Development of degeneration at the level adjacent to region anterior cervical discectomy and fusion performed is higher compared to non-adjacent levels. The level of fusion and the number of fusion levels have no effect on the development of degeneration. (The Medical Bulletin of Haseki 2015; 53:120-3

  6. UNITED STATES DEPARTMENT OF TRANSPORTATION GLOBAL POSITIONING SYSTEM (GPS) ADJACENT BAND COMPATIBILITY ASSESSMENT

    Science.gov (United States)

    2018-04-01

    The goal of the U.S. Department of Transportation (DOT) Global Positioning System (GPS) Adjacent Band Compatibility Assessment is to evaluate the maximum transmitted power levels of adjacent band radiofrequency (RF) systems that can be tolerated by G...

  7. Application of annealing for WWER vessels life extension

    International Nuclear Information System (INIS)

    Badanin, V.I.; Gorynin, I.V.; Nickolaev, V.A.; Dragunov, Y.G.; Fedorov, V.G.

    1989-01-01

    Safe operation of NPP is greatly dependent on the guarantee of reactor vessel brittle failure strength with account for the effect of radiation embrittlement of vessel material. Recovery of irradiated material properties is principally important way to extend radiation life of reactor vessel. The aim of this report is to demonstrate the efficiency of annealing for recovery of vessel material properties and extension of its service-life

  8. Analysis of CD83 antigen expression in human breast fibroadenoma and adjacent tissue.

    Science.gov (United States)

    Borges, Marcus Nascimento; Facina, Gil; Silva, Ismael Dale Cotrin Guerreiro; Waitzberg, Angela Flávia Logullo; Nazario, Afonso Celso Pinto

    2011-12-01

    Dendritic cell maturation is considered essential for starting an immune response. The CD83 antigen is an important marker of dendritic cell maturation. The objectives here were to analyze CD83 antigen expression in human breast fibroadenoma and breast tissue adjacent to the lesion and to identify clinical factors that might influence this expression. This was a retrospective study at a public university hospital, in which 29 histopathological samples of breast fibroadenoma and adjacent breast tissue, from 28 women of reproductive age, were analyzed. The immunohistochemistry method was used to analyze the cell expression of the antigen. The antigen expression in the cells was evaluated by means of random manual counting using an optical microscope. Positive expression of the CD83 antigen in the epithelial cells of the fibroadenoma (365.52; standard deviation ± 133.13) in relation to the adjacent breast tissue cells (189.59; standard deviation ± 140.75) was statistically larger (P fibroadenoma was positive and greater than in the adjacent breast tissue. Positive expression of the antigen in the adjacent breast tissue was influenced by parity, and was significantly more evident in nulliparous women.

  9. Proof testing of an explosion containment vessel

    Energy Technology Data Exchange (ETDEWEB)

    Esparza, E.D. [Esparza (Edward D.), San Antonio, TX (United States); Stacy, H.; Wackerle, J. [Los Alamos National Lab., NM (United States)

    1996-10-01

    A steel containment vessel was fabricated and proof tested for use by the Los Alamos National Laboratory at their M-9 facility. The HY-100 steel vessel was designed to provide total containment for high explosives tests up to 22 lb (10 kg) of TNT equivalent. The vessel was fabricated from an 11.5-ft diameter cylindrical shell, 1.5 in thick, and 2:1 elliptical ends, 2 in thick. Prior to delivery and acceptance, three types of tests were required for proof testing the vessel: a hydrostatic pressure test, air leak tests, and two full design charge explosion tests. The hydrostatic pressure test provided an initial static check on the capacity of the vessel and functioning of the strain instrumentation. The pneumatic air leak tests were performed before, in between, and after the explosion tests. After three smaller preliminary charge tests, the full design charge weight explosion tests demonstrated that no yielding occurred in the vessel at its rated capacity. The blast pressures generated by the explosions and the dynamic response of the vessel were measured and recorded with 33 strain channels, 4 blast pressure channels, 2 gas pressure channels, and 3 displacement channels. This paper presents an overview of the test program, a short summary of the methodology used to predict the design blast loads, a brief description of the transducer locations and measurement systems, some of the hydrostatic test strain and stress results, examples of the explosion pressure and dynamic strain data, and some comparisons of the measured data with the design loads and stresses on the vessel.

  10. Modeling fires in adjacent ship compartments with computational fluid dynamics

    International Nuclear Information System (INIS)

    Wix, S.D.; Cole, J.K.; Koski, J.A.

    1998-01-01

    This paper presents an analysis of the thermal effects on radioactive (RAM) transportation pack ages with a fire in an adjacent compartment. An assumption for this analysis is that the adjacent hold fire is some sort of engine room fire. Computational fluid dynamics (CFD) analysis tools were used to perform the analysis in order to include convective heat transfer effects. The analysis results were compared to experimental data gathered in a series of tests on the United States Coast Guard ship Mayo Lykes located at Mobile, Alabama. (authors)

  11. Issues in Sign Language Lexicography

    DEFF Research Database (Denmark)

    Zwitserlood, Inge; Kristoffersen, Jette Hedegaard; Troelsgård, Thomas

    2013-01-01

    ge lexicography has thus far been a relatively obscure area in the world of lexicography. Therefore, this article will contain background information on signed languages and the communities in which they are used, on the lexicography of sign languages, the situation in the Netherlands as well...

  12. Learning to Detect Traffic Signs

    DEFF Research Database (Denmark)

    Møgelmose, Andreas; Trivedi, Mohan M.; Moeslund, Thomas B.

    2012-01-01

    This study compares the performance of sign detection based on synthetic training data to the performance of detection based on real-world training images. Viola-Jones detectors are created for 4 different traffic signs with both synthetic and real data, and varying numbers of training samples. T...

  13. Concise Lexicon for Sign Linguistics

    NARCIS (Netherlands)

    dr. Jan Nijen Twilhaar; Dr. Beppie van den Bogaerde

    2016-01-01

    This extensive, well-researched and clearly formatted lexicon of a wide variety of linguistic terms is a long overdue. It is an extremely welcome addition to the bookshelves of sign language teachers, interpreters, linguists, learners and other sign language users, and of course of the Deaf

  14. Reactor pressure vessel design

    International Nuclear Information System (INIS)

    Foehl, J.

    1998-01-01

    As a result of the popularity of the Agencies report 'Neutron Irradiation Embrittlement of Reactor Pressure Vessel Steels' of 1975, it was decided that another report on this broad subject would be of use. In this report, background and contemporary views on specially identified areas of the subject are considered as self-contained chapters, written by experts. In chapter 2, the general principles of reactor pressure vessel design are elaborated. Crack and fracture initiation and propagation are treated in some detail

  15. Prestressed reactor vessel for nuclear power plants

    International Nuclear Information System (INIS)

    Schoening, J.; Schwiers, H.G.

    1982-01-01

    With usual pressure vessels for nuclear reactor plants, especially for gas-cooled nuclear reactors, the load occurring due to the inner overpressure, especially the tensile load affecting the vessel top and/or bottom, their axis of inertia being horizontal, shall be compensated without a supplementary modification in design of the top and/or the bottom. This is attained by choosing an appropriate prestressing system of the vessel wall in the field the top and/or the bottom, so that the top and/or the bottom form a tension vault directed towards the interior of the vessel. (orig.) [de

  16. Increase of cyclic durability of pressure vessels

    International Nuclear Information System (INIS)

    Vorona, V.A.; Zvezdin, Yu.I.

    1980-01-01

    The durability of multilayer pressure vessels under cyclic loading is compared with single-layer vessels. The relative conditional durability is calculated taking into account the assumption on the consequent destruction of layers and viewing a vessel wall as an indefinite plate. It is established that the durability is mainly determined by the number of layers and to a lesser degree depends on the relative size of the defect for the given layer thickness. The advantage of the multilayer vessels is the possibility of selecting layer materials so that to exclude the effect of agressive corrosion media on the strength [ru

  17. Visualization of femoral vessels in delayed bone scans - a sign of arteriosclerosis. A comparison of /sup 99m/Tc-MDP and /sup 99m/Tc-DPD

    Energy Technology Data Exchange (ETDEWEB)

    Lantto, T.; Jaervi, K.; Toivio, I.; Vaehaetalo, S.; Vorne, M.

    1989-05-01

    The activity of femoral vessels in delayed bone scans was evaluated visually in 237 consecutive patients and quantified in 40 female patients. In visual analysis the patients were randomly divided into three groups and in quantitative analysis into four groups of equal size. Two different MDP preparations and one DPD preparation were used as bone-seeking agents. With aging, the activity in femoral vessels increased with all agents in visual analysis, significantly with MDPs (P < 0.001) between patients less than or equal to 60 years and > 60 years. In female patients with all agents a significant increase in femoral activity was found (P < 0.001 with MDPs, P < 0.05 with DPD). In patients > 60 years, the femoral uptake was significantly higher with MDP when compared with the DPD uptake (P < 0.01 with MDP 1, P < 0.05 with MDP 2). Between the MDPs no significant differences were found. In quantitative analysis the femoral vessel to soft tissue ratio was significantly higher in patients > 70 years when compared with patients less than or equal to 50 years with MDP. No difference was found with DPD. Histological examination of excised arteries of ten patients with intense femoral uptake of MDP showed arteriosclerosis and calcification in all cases. The findings suggest that the femoral visualization in delayed bone scans is probably related to arteriosclerosis and is not a non specific finding. There may be age-related differences in the distribution of MDP and DPD.

  18. «Existe-t-il des signes visuels?» Rivisitazione del Traité du signe visueldel Groupe μ

    Directory of Open Access Journals (Sweden)

    Michele Amadò

    2008-06-01

    Full Text Available In order to develop its great potential, visual communication needs to be founded on the characteristics of the visual channel and on the typologies of the visual signs (iconic and plastic, therefore, on a specific semiotic and rhetoric distinct from the ones of the linguistic sign. Visual signs, in particular the noblest expressions like the artistic ones, reveal themselves more as aims rather than as means. They do not point away from themselves but to themselves: this connotation is founded on the autonomy of visual signs as regards the reported reality. The respective itineraries can emphasize the possibilities and inherent to a visually constructed logic with nonverbal characteristics.

  19. Signs of Resistance: Peer Learning of Sign Languages within "Oral" Schools for the Deaf

    Science.gov (United States)

    Anglin-Jaffe, Hannah

    2013-01-01

    This article explores the role of the Deaf child as peer educator. In schools where sign languages were banned, Deaf children became the educators of their Deaf peers in a number of contexts worldwide. This paper analyses how this peer education of sign language worked in context by drawing on two examples from boarding schools for the deaf in…

  20. Parkinsonian signs are a risk factor for falls.

    Science.gov (United States)

    Dahodwala, Nabila; Nwadiogbu, Chinwe; Fitts, Whitney; Partridge, Helen; Karlawish, Jason

    2017-06-01

    Parkinsonian signs are common, non-specific findings in older adults and associated with increased rates of dementia and mortality. It is important to understand which motor outcomes are associated with parkinsonian signs. To determine the role of parkinsonian signs on fall rates among older adults. We conducted a longitudinal study of primary care patients from the University of Pennsylvania Health System. Adults over 55 years were assessed at baseline through surveys and a neurological examination. We recorded falls over the following 2 years. Parkinsonian signs were defined as the presence of 2 of 4 cardinal signs. Incident falls were compared between subjects with and without parkinsonian signs, and modified Poisson regression used to adjust for potential confounders in the relationship between parkinsonian signs and falls. 982 subjects with a mean age of 68 (s.d. 8.8) years participated. 29% of participants fell and 12% exhibited parkinsonian signs at baseline. The unadjusted RR for falls among individuals with parkinsonian signs was 1.36 (95% CI 1.05-1.76, p=0.02). After adjusting for age, cognitive function, urinary incontinence, depression, diabetes, stroke and arthritis, individuals with parkinsonian signs were still 38% more likely to fall than those without parkinsonian signs (RR 1.38, 95% CI 1.04-1.82; p=0.03). Falls among those with parkinsonian signs were more likely to lead to injury (53% vs 37%; p=0.04). Parkinsonian signs are a significant, independent risk factor for falls. Early detection of this clinical state is important in order to implement fall prevention programs among primary care patients. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Traffic signs recognition for driving assistance

    Science.gov (United States)

    Sai Sangram Reddy, Yatham; Karthik, Devareddy; Rana, Nikunj; Jasmine Pemeena Priyadarsini, M.; Rajini, G. K.; Naseera, Shaik

    2017-11-01

    In the current circumstances with the innovative headway, we must be able to provide assistance to the driving in recognising the traffic signs on the roads. At present time, many reviews are being directed moving in the direction of the usage of a keen Traffic Systems. One field of this exploration is driving support systems, and many reviews are being directed to create frameworks which distinguish and perceive street signs in front of the vehicle, and afterward utilize the data to advise the driver or to even control the vehicle by implementing this system on self-driving vehicles. In this paper we propose a method to detect the traffic sign board in a frame using HAAR cascading and then identifying the sign on it. The output may be either given out in voice or can be displayed as per the driver’s convenience. Each of the Traffic Sign is recognised using a database of images of symbols used to train the KNN classifier using open CV libraries.

  2. Abdominal X-ray signs of intra-intestinal drug smuggling.

    Science.gov (United States)

    Niewiarowski, Sylwia; Gogbashian, Andrew; Afaq, Asim; Kantor, Robin; Win, Zarni

    2010-05-01

    "Body packers" either swallow or insert drug filled packets rectally or vaginally in order to smuggle illicit drugs. AXR is used routinely to screen suspects for the presence of intra-intestinal drug packages. AXR diagnosis can be difficult as stool or gas within the intestine may resemble ingested foreign bodies. We identify the frequency and co-existence of several signs; tic-tac sign, rosette sign, double condom sign, dense surrounding material, density and discover a new sign; parallelism, which will aid in increasing the radiological accuracy. We retrospectively reviewed 285 AXRs performed for suspicion of drug smuggling during the period of March 2006-March 2009 to identify the frequency of these signs. Of the 285 AXRs performed 59 were positive, 221 negative and five were indeterminate. The tic-tac sign was present in 93%, double condom sign in 73%, dense surrounding wrapping material in 36% and parallelism in 27%. Sixty one percentage of drug packages were iso-dense to faeces and 39% hyperdense. Twenty percentage of the positive abdominal radiographs demonstrated one of the radiographic signs, 39% demonstrated two signs, 32% demonstrated three and 7% four. The most common radiographic sign combination was the tic-tac sign with either dense surrounding material or double condom sign. The most commonly encountered radiographic sign is the tic-tac sign, followed by the double condom sign and dense surrounding material. We also discover a new sign, "parallelism" which although uncommon is highly specific. Accuracy is further increased by comparing the density of packages to faeces and looking for the co-existence of multiple signs. Copyright (c) 2010 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  3. Reactor-vessel-sectioning demonstration

    International Nuclear Information System (INIS)

    Lundgren, R.A.

    1981-09-01

    A technical demonstration was successfully completed of simulated reactor vessel sectioning using the combined techniques of air arc gouging and flame cutting. A 4-ft x 3-ft x 9-in. thick sample was fabricated of A36 carbon steel to simulate a reactor vessel wall. A 1/4-in. layer of stainless steel (SS) was tungsten inert gas (TIG)-welded to the carbon steel. Several techniques were considered to section the simulated reactor vessel; air arc gouging was selected to penetrate the stainless steel, and flame cutting was selected to sever the carbon steel. Three sectioning operations were demonstrated. For all three, the operating parameters were the same; but the position of the sample was varied. For the first cut, the sample was placed in a horizontal position, and it was successfully severed from the SS side. For the second cut, the sample was turned over and cut from the carbon steel side. Cutting from the carbon steel side has the advantages of cost reduction

  4. Definitions for warning signs and signs of severe dengue according to the WHO 2009 classification: Systematic review of literature.

    Science.gov (United States)

    Morra, Mostafa Ebraheem; Altibi, Ahmed M A; Iqtadar, Somia; Minh, Le Huu Nhat; Elawady, Sameh Samir; Hallab, Asma; Elshafay, Abdelrahman; Omer, Omer Abedlbagi; Iraqi, Ahmed; Adhikari, Purushottam; Labib, Jonair Hussein; Elhusseiny, Khaled Mosaad; Elgebaly, Ahmed; Yacoub, Sophie; Huong, Le Thi Minh; Hirayama, Kenji; Huy, Nguyen Tien

    2018-04-24

    Since warning signs and signs of severe dengue are defined differently between studies, we conducted a systematic review on how researchers defined these signs. We conducted an electronic search in Scopus to identify relevant articles, using key words including dengue, "warning signs," "severe dengue," and "classification." A total of 491 articles were identified through this search strategy and were subsequently screened by 2 independent reviewers for definitions of any of the warning or severe signs in the 2009 WHO dengue classification. We included all original articles published in English after 2009, classifying dengue by the 2009 WHO classification or providing the additional definition or criterion of warning signs and severity (besides the information of 2009 WHO). Analysis of the extracted data from 44 articles showed wide variations among definitions and cutoff values used by physicians to classify patients diagnosed with dengue infection. The establishment of clear definitions for warning signs and severity is essential to prevent unnecessary hospitalization and harmonizing the interpretation and comparability of epidemiological studies dedicated to dengue infection. Copyright © 2018 John Wiley & Sons, Ltd.

  5. Baking results of KSTAR vacuum vessel

    International Nuclear Information System (INIS)

    Kim, S. T.; Kim, Y. J.; Kim, K. M.; Im, D. S.; Joung, N. Y.; Yang, H. L.; Kim, Y. S.; Kwon, M.

    2009-01-01

    The Korea Superconducting Tokamak Advanced Research (KSTAR) is an advanced superconducting tokamak designed to establish a scientific and technological basis for an attractive fusion reactor. The fusion energy in the tokamak device is released through fusion reactions of light atoms such as deuterium or helium in hot plasma state, of which temperature reaches several hundreds of millions Celsius. The high temperature plasma is created in the vacuum vessel that provides ultra high vacuum status. Accordingly, it is most important for the vacuum condition to keep clean not only inner space but also surface of the vacuum vessel to make high quality plasma. There are two methods planned to clean the wall surface of the KSTAR vacuum vessel. One is surface baking and the other is glow discharge cleaning (GDC). To bake the vacuum vessel, De-Ionized (DI) water is heated to 130 .deg. C and circulated in the passage between double walls of the vacuum vessel (VV) in order to bake the surface. The GDC operation uses hydrogen and inert gas discharges. In this paper, general configuration and brief introduction of the baking result will be reported

  6. Reactor vessel supported by flexure member

    International Nuclear Information System (INIS)

    Crawford, J.D.; Pankow, B.

    1977-01-01

    According to the present invention there is provided an improved arrangement for supporting a reactor vessel within a containment structure against static and dynamic vertical loadings capable of being imposed as a result of a serious accident as well as during periods of normal plant operation. The support arrangement of the invention is, at the same time, capable of accommodating radial displacements that normally occur between the reactor vessel and the containment structure due to operational transients. The arrangement comprises a plurality of vertical columns connected between the reactor vessel and a support base within the containment structure. The columns are designed to accommodate relative displacements between the vessel and the containment structure by flexing. This eliminates the need for relative sliding movements and thus enables the columns to be securely fixed to the vessel. This elimination of a provision for relative sliding movements avoids the spaces or gaps between the retention members and the retained elements as occurred in prior art arrangements and, concomitantly, the danger of establishing impact forces on the retention members in the event of an accident is reduced. (author)

  7. Baking results of KSTAR vacuum vessel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, S. T.; Kim, Y. J.; Kim, K. M.; Im, D. S.; Joung, N. Y.; Yang, H. L.; Kim, Y. S.; Kwon, M. [National Fusion Research Institute, Daejeon (Korea, Republic of)

    2009-05-15

    The Korea Superconducting Tokamak Advanced Research (KSTAR) is an advanced superconducting tokamak designed to establish a scientific and technological basis for an attractive fusion reactor. The fusion energy in the tokamak device is released through fusion reactions of light atoms such as deuterium or helium in hot plasma state, of which temperature reaches several hundreds of millions Celsius. The high temperature plasma is created in the vacuum vessel that provides ultra high vacuum status. Accordingly, it is most important for the vacuum condition to keep clean not only inner space but also surface of the vacuum vessel to make high quality plasma. There are two methods planned to clean the wall surface of the KSTAR vacuum vessel. One is surface baking and the other is glow discharge cleaning (GDC). To bake the vacuum vessel, De-Ionized (DI) water is heated to 130 .deg. C and circulated in the passage between double walls of the vacuum vessel (VV) in order to bake the surface. The GDC operation uses hydrogen and inert gas discharges. In this paper, general configuration and brief introduction of the baking result will be reported.

  8. Signed Young Modules and Simple Specht Modules

    OpenAIRE

    Danz, Susanne; Lim, Kay Jin

    2015-01-01

    By a result of Hemmer, every simple Specht module of a finite symmetric group over a field of odd characteristic is a signed Young module. While Specht modules are parametrized by partitions, indecomposable signed Young modules are parametrized by certain pairs of partitions. The main result of this article establishes the signed Young module labels of simple Specht modules. Along the way we prove a number of results concerning indecomposable signed Young modules that are of independent inter...

  9. Irreducible Specht modules are signed Young modules

    OpenAIRE

    Hemmer, David J.

    2005-01-01

    Recently Donkin defined signed Young modules as a simultaneous generalization of Young and twisted Young modules for the symmetric group. We show that in odd characteristic, if a Specht module $S^\\lambda$ is irreducible, then $S^\\lambda$ is a signed Young module. Thus the set of irreducible Specht modules coincides with the set of irreducible signed Young modules. This provides evidence for our conjecture that the signed Young modules are precisely the class of indecomposable self-dual module...

  10. History of metaphoric signs in radiology

    Energy Technology Data Exchange (ETDEWEB)

    Baker, Stephen R., E-mail: bakersr@umdnj.edu; Noorelahi, Yasser M., E-mail: dr.ynoorelahi@gmail.com; Ghosh, Shanchita, E-mail: Ghoshs1@umdnj.edu; Yang, Lily C., E-mail: yangclily@gmail.com; Kasper, David J., E-mail: dkasp86@gmail.com

    2013-09-15

    Purpose: To survey the nearly 100 year history of metaphoric sign naming in radiology describing the pace of their overall accumulation in the radiology canon, their specific rates of growth by modality and subspecialty and the characteristics of the referents to which the signs are attached. Materials and methods: A comprehensive list of metaphoric signs was compiled from a search of articles in several major English language radiology journals, from a roster compiled in a monograph on the subject published in 1984 and from a search of several databases to find signs published in the first half of the 20th century. Results: The growth of radiological metaphorical signs naming was slow for several decades after the first one was published in 1918. It then increased rapidly until the 1980s encompassing all modalities and subspecialties. Recently the practice has shown a marked and steady decline. Conclusion: Metaphoric sign naming was a frequently reported contribution to the radiological literature in the second half of the 20th century corresponding with Radiology's growth as a descriptive discipline. Its decline since then may be a consequence of Radiology's evolution into a more analytic, data-driven field of inquiry.

  11. History of metaphoric signs in radiology

    International Nuclear Information System (INIS)

    Baker, Stephen R.; Noorelahi, Yasser M.; Ghosh, Shanchita; Yang, Lily C.; Kasper, David J.

    2013-01-01

    Purpose: To survey the nearly 100 year history of metaphoric sign naming in radiology describing the pace of their overall accumulation in the radiology canon, their specific rates of growth by modality and subspecialty and the characteristics of the referents to which the signs are attached. Materials and methods: A comprehensive list of metaphoric signs was compiled from a search of articles in several major English language radiology journals, from a roster compiled in a monograph on the subject published in 1984 and from a search of several databases to find signs published in the first half of the 20th century. Results: The growth of radiological metaphorical signs naming was slow for several decades after the first one was published in 1918. It then increased rapidly until the 1980s encompassing all modalities and subspecialties. Recently the practice has shown a marked and steady decline. Conclusion: Metaphoric sign naming was a frequently reported contribution to the radiological literature in the second half of the 20th century corresponding with Radiology's growth as a descriptive discipline. Its decline since then may be a consequence of Radiology's evolution into a more analytic, data-driven field of inquiry

  12. Assessment of W7-X plasma vessel pressurisation in case of LOCA taking into account in-vessel components

    Energy Technology Data Exchange (ETDEWEB)

    Urbonavičius, E., E-mail: Egidijus.Urbonavicius@lei.lt; Povilaitis, M., E-mail: Mantas.Povilaitis@lei.lt; Kontautas, A., E-mail: Aurimas.Kontautas@lei.lt

    2015-11-15

    Highlights: • Analysis of the vacuum vessel response to the LOCA in W7-X was performed using lumped-parameter codes COCOSYS and ASTEC. • Benchmarking of the results received with two codes provides more confidence in results and helps in identification of possible important differences in the modelling. • The performed analysis answered the questions set in the installed plasma vessel venting system during overpressure of PV in case of 40 mm diameter LOCA in “baking” mode. • Differences in time until opening the burst disk observed in ASTEC and COCOSYS results are caused by differences in heat transfer modelling. - Abstract: This paper presents the analysis of W7-X vacuum vessel response taking into account in-vessel components. A detailed analysis of the vacuum vessel response to the loss of coolant accident was performed using lumped-parameter codes COCOSYS and ASTEC. The performed analysis showed that the installed plasma vessel venting system prevents overpressure of PV in case of 40 mm diameter LOCA in “baking” mode. The performed analysis revealed differences in heat transfer modelling implemented in ASTEC and COCOSYS computer codes, which require further investigation to justify the correct approach for application to fusion facilities.

  13. Assessment of W7-X plasma vessel pressurisation in case of LOCA taking into account in-vessel components

    International Nuclear Information System (INIS)

    Urbonavičius, E.; Povilaitis, M.; Kontautas, A.

    2015-01-01

    Highlights: • Analysis of the vacuum vessel response to the LOCA in W7-X was performed using lumped-parameter codes COCOSYS and ASTEC. • Benchmarking of the results received with two codes provides more confidence in results and helps in identification of possible important differences in the modelling. • The performed analysis answered the questions set in the installed plasma vessel venting system during overpressure of PV in case of 40 mm diameter LOCA in “baking” mode. • Differences in time until opening the burst disk observed in ASTEC and COCOSYS results are caused by differences in heat transfer modelling. - Abstract: This paper presents the analysis of W7-X vacuum vessel response taking into account in-vessel components. A detailed analysis of the vacuum vessel response to the loss of coolant accident was performed using lumped-parameter codes COCOSYS and ASTEC. The performed analysis showed that the installed plasma vessel venting system prevents overpressure of PV in case of 40 mm diameter LOCA in “baking” mode. The performed analysis revealed differences in heat transfer modelling implemented in ASTEC and COCOSYS computer codes, which require further investigation to justify the correct approach for application to fusion facilities.

  14. Development of heat transfer enhancement techniques for external cooling of an advanced reactor vessel

    Science.gov (United States)

    Yang, Jun

    coatings by comparing the measurements with those for a plain vessel without coatings. An overall enhancement in nucleate boiling rates and CHF limits up to 100% were observed. Moreover, combination of data from quenching experiments and steady-state experiments produced new sets of boiling curves, which covered both the nucleate and transient boiling regimes with much greater accuracy. Beside the experimental work, a theoretical CHF model has also been developed by considering the vapor dynamics and the boiling-induced two-phase motions in three separate regions adjacent to the heating surface. The CHF model is capable of predicting the performance of micro-porous coatings with given particle diameter, porosity, media permeability and thickness. It is found that the present CHF model agrees favorably with the experimental data. Effects of an enhanced vessel/insulation structure on the local nucleate boiling rate and CHF limit have also been investigated experimentally. It is observed that the local two-phase flow quantities such as the local void fraction, quality, mean vapor velocity, mean liquid velocity, and mean vapor and liquid mass flow rates could have great impact on the local surface heat flux as boiling of water takes place on the vessel surface. An upward co-current two-phase flow model has been developed to predict the local two-phase flow behavior for different flow channel geometries, which are set by the design of insulation structures. It is found from the two-phase flow visualization experiments and the two-phase flow model calculations that the enhanced vessel/insulation structure greatly improved the steam venting process at the minimum gap location compared to the performance of thermal insulation structures without enhancement. Moveover, depending on the angular location, steady-state boiling experiments with the enhanced insulation design showed an enhancement of 1.8 to 3.0 times in the local critical heat flux. Finally, nucleate boiling and CHF

  15. The dynamics of microtidal lagoons and adjacent coasts

    NARCIS (Netherlands)

    Stive, M.J.F.; Capobianco, M.; Wang, Z.B.; Ruol, P.

    1996-01-01

    We have formulated an aggregated-scale behaviour-model for the interaction between a tidal basin and its adjacent coastal environment, without adopting a priory assumptions about their independent dynamic equilibrium behaviour. Necessarily so, the model combines observations and findings resuhing

  16. Development of Catamaran Fishing Vessel

    Directory of Open Access Journals (Sweden)

    A. Jamaluddin

    2010-11-01

    Full Text Available Multihull due to a couple of advantages has been the topic of extensive research work in naval architecture. In this study, a series of investigation of fishing vessel to save fuel energy was carried out at ITS. Two types of ship models, monohull (round bilge and hard chine and catamaran, a boat with two hulls (symmetrical and asymmetrical were developed. Four models were produced physically and numerically, tested (towing tank and simulated numerically (CFD code. The results of the two approaches indicated that the catamaran mode might have drag (resistance smaller than those of monohull at the same displacement. A layout of catamaran fishing vessel, proposed here, indicates the freedom of setting the deck equipments for fishing vessel.

  17. Metallurgy of steels for PWR pressure vessels

    International Nuclear Information System (INIS)

    Kepka, M.; Mocek, J.; Barackova, L.

    1980-01-01

    A survey and the chemical compositions are presented of reactor pressure vessel steels. The metallurgy is described of steel making for pressure vessels in Japan and the USSR. Both acidic and alkaline open-hearth steel is used for the manufacture of ingots. The leading world manufacturers of forging ingots for pressure vessels, however, exclusively use electric steel. Vacuum casting techniques are exclusively used. Experience is shown gained with the introduction of the manufacture of forging ingots for pressure vessels at SKODA, Plzen. The metallurgical procedure was tested utilizing alkaline open hearths, electric arc furnaces and facilities for vacuum casting of steel. Pure charge raw materials should be used for securing high steel purity. Prior to forging pressure vessel rings, not only should sufficiently big bottoms and heads be removed but also the ingot middle part should be scrapped showing higher contents of impurities and nonhomogeneous structure. (B.S.)

  18. Metallurgy of steels for PWR pressure vessels

    Energy Technology Data Exchange (ETDEWEB)

    Kepka, M; Mocek, J; Barackova, L [Skoda, Plzen (Czechoslovakia)

    1980-09-01

    A survey and the chemical compositions are presented of reactor pressure vessel steels. The metallurgy is described of steel making for pressure vessels in Japan and the USSR. Both acidic and alkaline open-hearth steel is used for the manufacture of ingots. The leading world manufacturers of forging ingots for pressure vessels, however, exclusively use electric steel. Vacuum casting techniques are exclusively used. Experience is shown gained with the introduction of the manufacture of forging ingots for pressure vessels at SKODA, Plzen. The metallurgical procedure was tested utilizing alkaline open hearths, electric arc furnaces and facilities for vacuum casting of steel. Pure charge raw materials should be used for securing high steel purity. Prior to forging pressure vessel rings, not only should sufficiently big bottoms and heads be removed but also the ingot middle part should be scrapped showing higher contents of impurities and nonhomogeneous structure.

  19. Nuclear reactor vessel fuel thermal insulating barrier

    Science.gov (United States)

    Keegan, C. Patrick; Scobel, James H.; Wright, Richard F.

    2013-03-19

    The reactor vessel of a nuclear reactor installation which is suspended from the cold leg nozzles in a reactor cavity is provided with a lower thermal insulating barrier spaced from the reactor vessel that has a hemispherical lower section that increases in volume from the center line of the reactor to the outer extent of the diameter of the thermal insulating barrier and smoothly transitions up the side walls of the vessel. The space between the thermal insulating harrier and the reactor vessel forms a chamber which can be flooded with cooling water through passive valving to directly cool the reactor vessel in the event of a severe accident. The passive inlet valve for the cooling water includes a buoyant door that is normally maintained sealed under its own weight and floats open when the cavity is Hooded. Passively opening steam vents are also provided.

  20. Vessel size measurements in angiograms: A comparison of techniques

    International Nuclear Information System (INIS)

    Hoffmann, Kenneth R.; Nazareth, Daryl P.; Miskolczi, Laszlo; Gopal, Anant; Wang Zhou; Rudin, Stephen; Bednarek, Daniel R.

    2002-01-01

    As interventional procedures become more complicated, the need for accurate quantitative vascular information increases. In response to this need, many commercial vendors provide techniques for measurement of vessel sizes, usually based on derivative techniques. In this study, we investigate the accuracy of several techniques used in the measurement of vessel size. Simulated images of vessels having circular cross sections were generated and convolved with various focal spot distributions taking into account the magnification. These vessel images were then convolved with Gaussian image detector line spread functions (LSFs). Additionally, images of a phantom containing vessels with a range of diameters were acquired for the 4.5'', 6'', 9'', and 12'' modes of an image intensifier-TV (II-TV) system. Vessel sizes in the images were determined using a first-derivative technique, a second-derivative technique, a linear combination of these two measured sizes, a thresholding technique, a densitometric technique, and a model-based technique. For the same focal spot size, the shape of the focal spot distribution does not affect measured vessel sizes except at large magnifications. For vessels with diameters larger than the full-width-at-half-maximum (FWHM) of the LSF, accurate vessel sizes (errors ∼0.1 mm) could be obtained by using an average of sizes determined by the first and second derivatives. For vessels with diameters smaller than the FWHM of the LSF, the densitometric and model-based techniques can provide accurate vessel sizes when these techniques are properly calibrated

  1. Intraabdominal laparoscopy-assisted "open" vessel ligation of testicular vessels: a potential treatment for varicocele.

    Science.gov (United States)

    Miyano, Go; Miyahara, Katsumi; Halibieke, Abudebieke; Lane, Geoffrey J; Okazaki, Tadaharu; Yamataka, Atsuyuki

    2011-10-01

    We tested our laparoscopy-assisted "open" ligation (LOL) technique on testicular vessels. We ligated the left testicular artery and vein (TAV) in 8-week-old male Wister rats using LOL (LOL group; n=10) or laparotomy (open group; n=10). In LOL, a 0-degree laparoscope was introduced through a 5-mm epigastric trocar. A 3-mm grasper was used to expose the left TAV. A lapa-her-closure (LHC) needle loaded with 3-0 SurgiPro was directly inserted into the left lower quadrant where the left TAV should be and advanced under the vessels, and the suture material was released leaving one end outside. The LHC was then withdrawn a little and advanced again over the vessels to grasp the end of the suture material just released to bring it outside. This was proximally repeated. The two ends of both sutures were conventionally tied outside, and the knot was passed through the insertion site and tightened around the vessels. In the open group, the left TAV were ligated using two 3-0 SurgiPro ties. In both groups, the right side was left intact. All rats were sacrificed 2 weeks postoperatively, and both testes were examined with hematoxylin and eosin. Treatment time was 5-7 minutes for LOL and 7-8 minutes for the open group. Postoperative recovery was uneventful. No adhesions were present between the ligated vessels and bowel in any rat. Histopathology of all left testes showed coagulative necrosis of germinal cells and seminiferous tubules; all right testes were normal. LOL appears to be as effective as open ligation and may find application for treating varicocele.

  2. Constructing an optimal facility layout to maximize adjacency as a function of common boundary length

    Science.gov (United States)

    Ghassemi Tari, Farhad; Neghabi, Hossein

    2018-03-01

    An effective facility layout implies that departments with high flow are laid adjacent. However, in the case of a very narrow boundary length between the neighbouring departments, the adjacency would actually be useless. In traditional layout design methods, a score is generally assigned independent of the department's boundary length. This may result in a layout design with a restricted material flow. This article proposes a new concept of adjacency in which the department pairs are laid adjacent with a wider path. To apply this concept, a shop with unequal rectangular departments is contemplated and a mathematical programming model with the objective of maximizing the sum of the adjacency degrees is proposed. A computational experiment is conducted to demonstrate the efficiency of the layout design. It is demonstrated that the new concept provides a more efficient and a more realistic layout design.

  3. Transition from Sign-Reversed to Sign-Preserved Cooper-Pairing Symmetry in Sulfur-Doped Iron Selenide Superconductors.

    Science.gov (United States)

    Wang, Qisi; Park, J T; Feng, Yu; Shen, Yao; Hao, Yiqing; Pan, Bingying; Lynn, J W; Ivanov, A; Chi, Songxue; Matsuda, M; Cao, Huibo; Birgeneau, R J; Efremov, D V; Zhao, Jun

    2016-05-13

    An essential step toward elucidating the mechanism of superconductivity is to determine the sign or phase of the superconducting order parameter, as it is closely related to the pairing interaction. In conventional superconductors, the electron-phonon interaction induces attraction between electrons near the Fermi energy and results in a sign-preserved s-wave pairing. For high-temperature superconductors, including cuprates and iron-based superconductors, prevalent weak coupling theories suggest that the electron pairing is mediated by spin fluctuations which lead to repulsive interactions, and therefore that a sign-reversed pairing with an s_{±} or d-wave symmetry is favored. Here, by using magnetic neutron scattering, a phase sensitive probe of the superconducting gap, we report the observation of a transition from the sign-reversed to sign-preserved Cooper-pairing symmetry with insignificant changes in T_{c} in the S-doped iron selenide superconductors K_{x}Fe_{2-y}(Se_{1-z}S_{z})_{2}. We show that a rather sharp magnetic resonant mode well below the superconducting gap (2Δ) in the undoped sample (z=0) is replaced by a broad hump structure above 2Δ under 50% S doping. These results cannot be readily explained by simple spin fluctuation-exchange pairing theories and, therefore, multiple pairing channels are required to describe superconductivity in this system. Our findings may also yield a simple explanation for the sometimes contradictory data on the sign of the superconducting order parameter in iron-based materials.

  4. Tritium in Exit Signs | RadTown USA | US EPA

    Science.gov (United States)

    2017-08-07

    Many exit signs contain tritium to light the sign without batteries or electricity. Using tritium in exit signs allows the sign to remain lit if the power goes out. Tritium is most dangerous when it is inhaled or swallowed. Never tamper with a tritium exit sign. If a tritium exit sign is broken, leave the area immediately and notify the building maintenance staff.

  5. Fast Drawing of Traffic Sign Using Mobile Mapping System

    Science.gov (United States)

    Yao, Q.; Tan, B.; Huang, Y.

    2016-06-01

    Traffic sign provides road users with the specified instruction and information to enhance traffic safety. Automatic detection of traffic sign is important for navigation, autonomous driving, transportation asset management, etc. With the advance of laser and imaging sensors, Mobile Mapping System (MMS) becomes widely used in transportation agencies to map the transportation infrastructure. Although many algorithms of traffic sign detection are developed in the literature, they are still a tradeoff between the detection speed and accuracy, especially for the large-scale mobile mapping of both the rural and urban roads. This paper is motivated to efficiently survey traffic signs while mapping the road network and the roadside landscape. Inspired by the manual delineation of traffic sign, a drawing strategy is proposed to quickly approximate the boundary of traffic sign. Both the shape and color prior of the traffic sign are simultaneously involved during the drawing process. The most common speed-limit sign circle and the statistic color model of traffic sign are studied in this paper. Anchor points of traffic sign edge are located with the local maxima of color and gradient difference. Starting with the anchor points, contour of traffic sign is drawn smartly along the most significant direction of color and intensity consistency. The drawing process is also constrained by the curvature feature of the traffic sign circle. The drawing of linear growth is discarded immediately if it fails to form an arc over some steps. The Kalman filter principle is adopted to predict the temporal context of traffic sign. Based on the estimated point,we can predict and double check the traffic sign in consecutive frames.The event probability of having a traffic sign over the consecutive observations is compared with the null hypothesis of no perceptible traffic sign. The temporally salient traffic sign is then detected statistically and automatically as the rare event of having a

  6. Cheboygan Vessel Base

    Data.gov (United States)

    Federal Laboratory Consortium — Cheboygan Vessel Base (CVB), located in Cheboygan, Michigan, is a field station of the USGS Great Lakes Science Center (GLSC). CVB was established by congressional...

  7. Reactors with pressure vessel in pre-stressed concrete

    International Nuclear Information System (INIS)

    Devillers, Christian; Lafore, Pierre

    1964-12-01

    After having proposed a general description of the evolution of the general design of reactors with a vessel in pre-stressed concrete, this report outlines the interest of this technical solution of a vessel in pre-stressed concrete with integrated exchangers, which is to replace steel vessel. This solution is presented as much safer. The authors discuss the various issues related to protection: inner and outer biological protection of the vessel, material protection (against heating, steel irradiation, Wigner effect, and moderator radiolytic corrosion). They report the application of calculation methods: calculation of vessel concrete heating, study of the intermediate zone in integrated reactors, neutron spectrum and flows in the core of a graphite pile

  8. Adult Sail Sign: Radiographic and Computed Tomographic Features

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yu-Jin; Han, Daehee; Koh, Young Hwan; Zo, Joo Hee; Kim, Sang-Hyun; Kim, Deog Kyeom; Lee, Jeong Sang; Moon, Hyeon Jong; Kim, Jong Seung; Chun, Eun Ju; Youn, Byung Jae; Lee, Chang Hyun; Kim, Sam Soo (Dept. of Radiology, Cheil General Hospital, Kwandong Univ. College of Medicine, Seoul (KR))

    2008-02-15

    Background: The sail sign is a well-known radiographic feature of the pediatric chest. This sign can be observed in an adult population as well, but for a different reason. Purpose: To investigate the sail sign appearing in adult chest radiography. Material and Methods: Based on two anecdotal adult cases in which frontal chest radiographs showed the sail sign, we prospectively screened radiographs of 10,238 patients to determine the incidence of the sail sign found in adults in their 40s or older. The cause of the sail sign was assessed using computed tomography (CT). Results: The sail sign was revealed in 10 (seven males, three females; median age 60.6 years) of 10,238 patients. Of these 10 patients with a sail sign on frontal radiographs, eight underwent CT. The frontal radiographs of these 10 patients showed a concave superior margin toward the lung in nine patients, a concave inferior margin in five, and a double-lined inferior margin in three. Lateral radiographs disclosed a focal opacity over the minor fissure in five of six patients, which was either fuzzy (n = 4) or sharp (n = 1) in its upper margin, and was sometimes double lined in the inferior margin (n = 3). CT revealed the anterior mediastinal fat to be the cause of the radiographic sail sign, which stretched laterally from the mediastinum to insinuate into the minor fissure. Conclusion: The incidence of sail sign on adult chest radiographs is about 0.1%. The sign is specific enough to eliminate the need for more sophisticated imaging

  9. Adult Sail Sign: Radiographic and Computed Tomographic Features

    International Nuclear Information System (INIS)

    Lee, Yu-Jin; Han, Daehee; Koh, Young Hwan; Zo, Joo Hee; Kim, Sang-Hyun; Kim, Deog Kyeom; Lee, Jeong Sang; Moon, Hyeon Jong; Kim, Jong Seung; Chun, Eun Ju; Y oun, Byung Jae; Lee, Chang Hyun; Kim, Sam Soo

    2008-01-01

    Background: The sail sign is a well-known radiographic feature of the pediatric chest. This sign can be observed in an adult population as well, but for a different reason. Purpose: To investigate the sail sign appearing in adult chest radiography. Material and Methods: Based on two anecdotal adult cases in which frontal chest radiographs showed the sail sign, we prospectively screened radiographs of 10,238 patients to determine the incidence of the sail sign found in adults in their 40s or older. The cause of the sail sign was assessed using computed tomography (CT). Results: The sail sign was revealed in 10 (seven males, three females; median age 60.6 years) of 10,238 patients. Of these 10 patients with a sail sign on frontal radiographs, eight underwent CT. The frontal radiographs of these 10 patients showed a concave superior margin toward the lung in nine patients, a concave inferior margin in five, and a double-lined inferior margin in three. Lateral radiographs disclosed a focal opacity over the minor fissure in five of six patients, which was either fuzzy (n = 4) or sharp (n = 1) in its upper margin, and was sometimes double lined in the inferior margin (n = 3). CT revealed the anterior mediastinal fat to be the cause of the radiographic sail sign, which stretched laterally from the mediastinum to insinuate into the minor fissure. Conclusion: The incidence of sail sign on adult chest radiographs is about 0.1%. The sign is specific enough to eliminate the need for more sophisticated imaging

  10. Adult sail sign: radiographic and computed tomographic features.

    Science.gov (United States)

    Lee, Yu-Jin; Han, Daehee; Koh, Young Hwan; Zo, Joo Hee; Kim, Sang-Hyun; Kim, Deog Kyeom; Lee, Jeong Sang; Moon, Hyeon Jong; Kim, Jong Seung; Chun, Eun Ju; Youn, Byung Jae; Lee, Chang Hyun; Kim, Sam Soo

    2008-02-01

    The sail sign is a well-known radiographic feature of the pediatric chest. This sign can be observed in an adult population as well, but for a different reason. To investigate the sail sign appearing in adult chest radiography. Based on two anecdotal adult cases in which frontal chest radiographs showed the sail sign, we prospectively screened radiographs of 10,238 patients to determine the incidence of the sail sign found in adults in their 40s or older. The cause of the sail sign was assessed using computed tomography (CT). The sail sign was revealed in 10 (seven males, three females; median age 60.6 years) of 10,238 patients. Of these 10 patients with a sail sign on frontal radiographs, eight underwent CT. The frontal radiographs of these 10 patients showed a concave superior margin toward the lung in nine patients, a concave inferior margin in five, and a double-lined inferior margin in three. Lateral radiographs disclosed a focal opacity over the minor fissure in five of six patients, which was either fuzzy (n = 4) or sharp (n = 1) in its upper margin, and was sometimes double lined in the inferior margin (n = 3). CT revealed the anterior mediastinal fat to be the cause of the radiographic sail sign, which stretched laterally from the mediastinum to insinuate into the minor fissure. The incidence of sail sign on adult chest radiographs is about 0.1%. The sign is specific enough to eliminate the need for more sophisticated imaging.

  11. Adjacent segment disease and C-ADR: promises fulfilled?

    Science.gov (United States)

    Riew, K Daniel; Schenk-Kisser, Jeannette M.; Skelly, Andrea C.

    2012-01-01

    Study design: Systematic review. Clinical question: Do the rates and timing of adjacent segment disease (ASD) differ between cervical total disc arthroplasty (C-ADR) and anterior cervical discectomy and fusion (ACDF) in patients treated for cervical degenerative disc disease? Methods: A systematic search of MEDLINE/PubMed and bibliographies of key articles was done to identify studies with long-term follow-up for symptomatic and/or radiographic ASD comparing C-ADR with fusion for degenerative disc disease of the cervical spine. The focus was on studies with longer follow-up (48–60 months) of primary US Food and Drug Administration trials of Prestige ST, Prodisc-C, and Bryan devices as available. Trials of other discs with a minimum of 24 months follow-up were considered for inclusion. Studies evaluating lordosis/angle changes at adjacent segments and case series were excluded. Results: From 14 citations identified, four reports from three randomized controlled trials and four nonrandomized studies are summarized. Risk differences between C-ADR and ACF for symptomatic ASD were 1.5%–2.3% and were not significant across RCT reports. Time to development of ASD did not significantly differ between treatments. Rates of radiographic ASD were variable. No meaningful comparison of ASD rates based on disc design was possible. No statistical differences in adjacent segment range of motion were noted between treatment groups. Conclusion: Our analysis reveals that, to date, there is no evidence that arthroplasty decreases ASD compared with ACDF; the promise of arthroplasty decreasing ASD has not been fulfilled. PMID:23236312

  12. Computerized reactor pressure vessel materials information system

    International Nuclear Information System (INIS)

    Strosnider, J.; Monserrate, C.; Kenworthy, L.D.; Tether, C.D.

    1980-10-01

    A computerized information system for storage and retrieval of reactor pressure vessel materials data was established, as part of Task Action Plan A-11, Reactor Vessel Materials Toughness. Data stored in the system are necessary for evaluating the resistance of reactor pressure vessels to flaw-induced fracture. This report includes (1) a description of the information system; (2) guidance on accessing the system; and (3) a user's manual for the system

  13. Time integrated ratio of wrong-sign to right-sign $D^0 \\rightarrow K\\pi$ decays in 2010 data at LHCb

    CERN Document Server

    The LHCb Collaboration

    2011-01-01

    First results of the measurement on wrong-sign $D^0 \\rightarrow K^{+} \\pi^{-}$ decays based on the 2010 dataset taken with the LHCb detector are presented. The ratio of wrong-sign to right-sign ($D^0 \\rightarrow K^{-} \\pi^{+}$) $D^0$ decays corrected for the decay time acceptance is determined to be $R_{{\\rm corr}}=(0.409 \\pm 0.031 ({\\rm stat.}) \\pm 0.039 ({\\rm sys.})) \\% $. This analysis is the first step towards a measurement of the time-dependent wrong-sign to right-sign ratio from which the $D^0$ mixing parameters can be extracted.

  14. How to replace a reactor pressure vessel

    International Nuclear Information System (INIS)

    Huber, R.

    1996-01-01

    A potential life extending procedure for a nuclear reactor after, say, 40 years of service life, might in some circumstances be the replacement of the reactor pressure vessel. Neutron induced degradation of the vessel might make replacement by one of a different material composition desirable, for example. Although the replacement of heavy components, such as steam generators, has been possible for many years, the pressure vessel presents a much more demanding task if only because it is highly irradiated. Some preliminary feasibility studies by Siemens are reported for the two removal strategies that might be considered. These are removal of the entire pressure vessel in one piece and dismantling it into sections. (UK)

  15. TMI-2 Vessel Investigation Project integration report

    Energy Technology Data Exchange (ETDEWEB)

    Wolf, J. R.; Rempe, J. L.; Stickler, L. A.; Korth, G. E.; Diercks, D. R.; Neimark, L. A.; Akers, D W; Schuetz, B. K.; Shearer, T L; Chavez, S. A.; Thinnes, G. L.; Witt, R. J.; Corradini, M L; Kos, J. A. [EG and G Idaho, Inc., Idaho Falls, ID (United States)

    1994-03-01

    The Three Mile Island Unit 2 (TMI-2) Vessel Investigation Project (VIP) was an international effort that was sponsored by the Nuclear Energy Agency of the Organization for Economic Cooperation and Development. The primary objectives of the VIP were to extract and examine samples from the lower head and to evaluate the potential modes of failure and the margin of structural integrity that remained in the TMI-2 reactor vessel during the accident. This report presents a summary of the major findings and conclusions that were developed from research during the VIP. Results from the various elements of the project are integrated to form a cohesive understanding of the vessel`s condition after the accident.

  16. Lung vessel segmentation in CT images using graph-cuts

    Science.gov (United States)

    Zhai, Zhiwei; Staring, Marius; Stoel, Berend C.

    2016-03-01

    Accurate lung vessel segmentation is an important operation for lung CT analysis. Filters that are based on analyzing the eigenvalues of the Hessian matrix are popular for pulmonary vessel enhancement. However, due to their low response at vessel bifurcations and vessel boundaries, extracting lung vessels by thresholding the vesselness is not sufficiently accurate. Some methods turn to graph-cuts for more accurate segmentation, as it incorporates neighbourhood information. In this work, we propose a new graph-cuts cost function combining appearance and shape, where CT intensity represents appearance and vesselness from a Hessian-based filter represents shape. Due to the amount of voxels in high resolution CT scans, the memory requirement and time consumption for building a graph structure is very high. In order to make the graph representation computationally tractable, those voxels that are considered clearly background are removed from the graph nodes, using a threshold on the vesselness map. The graph structure is then established based on the remaining voxel nodes, source/sink nodes and the neighbourhood relationship of the remaining voxels. Vessels are segmented by minimizing the energy cost function with the graph-cuts optimization framework. We optimized the parameters used in the graph-cuts cost function and evaluated the proposed method with two manually labeled sub-volumes. For independent evaluation, we used 20 CT scans of the VESSEL12 challenge. The evaluation results of the sub-volume data show that the proposed method produced a more accurate vessel segmentation compared to the previous methods, with F1 score 0.76 and 0.69. In the VESSEL12 data-set, our method obtained a competitive performance with an area under the ROC curve of 0.975, especially among the binary submissions.

  17. 50 CFR 85.43 - Signs and symbols.

    Science.gov (United States)

    2010-10-01

    ... sign. (i) You may place the message “P PUMP OUT”, “P PUMPOUT STATION”, “P PORTABLE TOILET DUMP STATION... information signs at pumpout and portable toilet dump stations. Such information should indicate fees... sign at the entrance to a marina advertising the presence of a pumpout and/or portable toilet dump...

  18. 33 CFR 110.168 - Hampton Roads, Virginia and adjacent waters (Datum: NAD 83).

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Hampton Roads, Virginia and adjacent waters (Datum: NAD 83). 110.168 Section 110.168 Navigation and Navigable Waters COAST GUARD..., Virginia and adjacent waters (Datum: NAD 83). (a) Anchorage Grounds—(1) Anchorage A [Naval Anchorage]. The...

  19. FAST DRAWING OF TRAFFIC SIGN USING MOBILE MAPPING SYSTEM

    Directory of Open Access Journals (Sweden)

    Q. Yao

    2016-06-01

    Full Text Available Traffic sign provides road users with the specified instruction and information to enhance traffic safety. Automatic detection of traffic sign is important for navigation, autonomous driving, transportation asset management, etc. With the advance of laser and imaging sensors, Mobile Mapping System (MMS becomes widely used in transportation agencies to map the transportation infrastructure. Although many algorithms of traffic sign detection are developed in the literature, they are still a tradeoff between the detection speed and accuracy, especially for the large-scale mobile mapping of both the rural and urban roads. This paper is motivated to efficiently survey traffic signs while mapping the road network and the roadside landscape. Inspired by the manual delineation of traffic sign, a drawing strategy is proposed to quickly approximate the boundary of traffic sign. Both the shape and color prior of the traffic sign are simultaneously involved during the drawing process. The most common speed-limit sign circle and the statistic color model of traffic sign are studied in this paper. Anchor points of traffic sign edge are located with the local maxima of color and gradient difference. Starting with the anchor points, contour of traffic sign is drawn smartly along the most significant direction of color and intensity consistency. The drawing process is also constrained by the curvature feature of the traffic sign circle. The drawing of linear growth is discarded immediately if it fails to form an arc over some steps. The Kalman filter principle is adopted to predict the temporal context of traffic sign. Based on the estimated point,we can predict and double check the traffic sign in consecutive frames.The event probability of having a traffic sign over the consecutive observations is compared with the null hypothesis of no perceptible traffic sign. The temporally salient traffic sign is then detected statistically and automatically as the rare

  20. Edges and vertices in a unique signed circle in a signed graph

    Directory of Open Access Journals (Sweden)

    Richard Behr

    2017-12-01

    Full Text Available We examine the conditions under which a signed graph contains an edge or a vertex that is contained in a unique negative circle or a unique positive circle. For an edge in a unique signed circle, the positive and negative case require the same structure on the underlying graph, but the requirements on the signature are different. We characterize the structure of the underlying graph necessary to support such an edge in terms of bridges of a circle. We then use the results from the edge version of the problem to help solve the vertex version.

  1. Constraints on Negative Prefixation in Polish Sign Language.

    Science.gov (United States)

    Tomaszewski, Piotr

    2015-01-01

    The aim of this article is to describe a negative prefix, NEG-, in Polish Sign Language (PJM) which appears to be indigenous to the language. This is of interest given the relative rarity of prefixes in sign languages. Prefixed PJM signs were analyzed on the basis of both a corpus of texts signed by 15 deaf PJM users who are either native or near-native signers, and material including a specified range of prefixed signs as demonstrated by native signers in dictionary form (i.e. signs produced in isolation, not as part of phrases or sentences). In order to define the morphological rules behind prefixation on both the phonological and morphological levels, native PJM users were consulted for their expertise. The research results can enrich models for describing processes of grammaticalization in the context of the visual-gestural modality that forms the basis for sign language structure.

  2. Blood Vessels in Allotransplantation.

    Science.gov (United States)

    Abrahimi, P; Liu, R; Pober, J S

    2015-07-01

    Human vascularized allografts are perfused through blood vessels composed of cells (endothelium, pericytes, and smooth muscle cells) that remain largely of graft origin and are thus subject to host alloimmune responses. Graft vessels must be healthy to maintain homeostatic functions including control of perfusion, maintenance of permselectivity, prevention of thrombosis, and participation in immune surveillance. Vascular cell injury can cause dysfunction that interferes with these processes. Graft vascular cells can be activated by mediators of innate and adaptive immunity to participate in graft inflammation contributing to both ischemia/reperfusion injury and allograft rejection. Different forms of rejection may affect graft vessels in different ways, ranging from thrombosis and neutrophilic inflammation in hyperacute rejection, to endothelialitis/intimal arteritis and fibrinoid necrosis in acute cell-mediated or antibody-mediated rejection, respectively, and to diffuse luminal stenosis in chronic rejection. While some current therapies targeting the host immune system do affect graft vascular cells, direct targeting of the graft vasculature may create new opportunities for preventing allograft injury and loss. © Copyright 2015 The American Society of Transplantation and the American Society of Transplant Surgeons.

  3. Irradiation embrittlement of reactor vessel steels

    International Nuclear Information System (INIS)

    Bros, J.

    2000-01-01

    From the historical decision of closing the Yankee Rowe NPP because of the uncertainties on the level of reactor pressure vessel neutron embrittlement, this paper reviews the technical-scientist bases of the degradation phenomena, and refers to the evolution of reactor pressure vessel radiation surveillance programs. (Author)

  4. Segmentation of British Sign Language (BSL): mind the gap!

    Science.gov (United States)

    Orfanidou, Eleni; McQueen, James M; Adam, Robert; Morgan, Gary

    2015-01-01

    This study asks how users of British Sign Language (BSL) recognize individual signs in connected sign sequences. We examined whether this is achieved through modality-specific or modality-general segmentation procedures. A modality-specific feature of signed languages is that, during continuous signing, there are salient transitions between sign locations. We used the sign-spotting task to ask if and how BSL signers use these transitions in segmentation. A total of 96 real BSL signs were preceded by nonsense signs which were produced in either the target location or another location (with a small or large transition). Half of the transitions were within the same major body area (e.g., head) and half were across body areas (e.g., chest to hand). Deaf adult BSL users (a group of natives and early learners, and a group of late learners) spotted target signs best when there was a minimal transition and worst when there was a large transition. When location changes were present, both groups performed better when transitions were to a different body area than when they were within the same area. These findings suggest that transitions do not provide explicit sign-boundary cues in a modality-specific fashion. Instead, we argue that smaller transitions help recognition in a modality-general way by limiting lexical search to signs within location neighbourhoods, and that transitions across body areas also aid segmentation in a modality-general way, by providing a phonotactic cue to a sign boundary. We propose that sign segmentation is based on modality-general procedures which are core language-processing mechanisms.

  5. Effect of light-curable fluoride varnish on enamel demineralization adjacent to orthodontic brackets: an in-vivo study.

    Science.gov (United States)

    Mehta, Anurag; Paramshivam, Ganesh; Chugh, Vinay Kumar; Singh, Surjit; Halkai, Sudha; Kumar, Santosh

    2015-11-01

    The purpose of this in-vivo study was to evaluate the effect of a single application of Clinpro XT (3M ESPE, Pymble, New South Wales, Australia), a light-curable fluoride varnish, on enamel demineralization adjacent to orthodontic brackets. Thirty-eight patients (152 teeth) whose orthodontic treatment involved extraction of 4 first premolars were recruited. Two premolars each were assigned to the control group (no treatment) and the experimental group (received fluoride varnish application). The study was designed as a nonrandomized split-mouth study in which diagonally opposite quadrants received the same treatment. After the bonding procedures, a sectional T-loop was ligated into each bracket to serve as a site for plaque retention for enhanced demineralization. Clinpro XT was applied on the buccal surfaces adjacent to the brackets on all teeth in the experimental group only. Teeth in both groups were extracted after 15 days (n = 30), 30 days (n = 30), 45 days (n = 30), 90 days (n = 18), and 120 days (n = 18). Buccolingual sections were then evaluated under polarized light microscopy. After we excluded the dropouts, the mean depth of the demineralized enamel lesions was measured in final sample of 126 teeth. The Mann-Whitney test was used for comparison of the groups. In the control group, the depths of the demineralized enamel lesions increased from 30 to 120 days, whereas in the experimental group no sign of demineralization was noted throughout the observation period except for 3 teeth. Significant differences in the depths of demineralized lesions were found between the study groups. Clinpro XT light-curable fluoride varnish may be a reasonable alternative in the reduction of enamel demineralization around orthodontic brackets, especially in noncompliant and high-risk patients. Copyright © 2015 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  6. Retinal vessel diameters in relation to hematocrit variation during acclimatization of highlanders to sea level altitude

    DEFF Research Database (Denmark)

    Kofoed, Peter Kristian; Sander, Birgit; Zubieta-Calleja, Gustavo

    2009-01-01

    PURPOSE: To examine variations in retinal vessel diameters during acclimatization of native highlanders to normobaric normoxia at sea level. METHODS: Fifteen healthy residents of the greater La Paz region in Bolivia (3600 m above sea level) were examined thrice over a 72-day period, after having...... traveled by airplane to Copenhagen, Denmark, near sea level. RESULTS: In the study subjects, hematocrit decreased from 49.6% (day 2) to 45.9% (P = 0.0066, day 23) and 41.7% (P ... diameters were indistinguishable from baseline after 72 days. No funduscopic signs of retinopathy were observed. Arterial blood pressure remained stable throughout the study. CONCLUSIONS: Although a 16% reduction in hematocrit occurred between days 2 and 72 after arrival at sea level, the only significant...

  7. [Usefulness of AccuSign in emergency room].

    Science.gov (United States)

    Nakamura, Yoshihiko; Nakano, Minoru; Takahashi, Eiji; Suzuki, Hiroyuki; Hasuike, Toshikazu; Akuzawa, Hisashi; Yuasa, Hideko

    2012-09-01

    TriageDOA is effective for screening patients with methamphetamine intoxication, but false positives also sometimes occur. A definite diagnosis is made by performing an instrumental analysis for methamphetamine intoxication, but this is difficult to conduct in general hospitals. AccuSign using immunochromatography can identify methamphetamine (MET) and amphetamine (AMP) individually. An improvement in the diagnostic accuracy is expected by combining the measurements of both AccuSign MET and AMP. We herein investigated the diagnostic accuracy of AccuSign. THE SUBJECTS AND METHOD: Investigation A: The subjects comprised 115 cases of urine samples that were brought to the crime laboratory of the Gunma prefectural police (hereinafter, crime laboratory) under suspicion of methamphetamine intoxication from January 2006 to April 2009. The outcomes of the measurements of MET from AccuSign MET, AMP and instrumental analyses were compared. Investigation B: The subjects comprised 16 cases in which TriageDOA was positive and AccuSign MET and AMP were performed on patients suspected of methamphetamine intoxication or patients with a disturbance of consciousness in our hospital from July 2009 to October 2010. The outcomes of the measurements of MET and AMP from AccuSign MET, AMP and instrumental analyses were compared. Investigation A: The results were classified into positive for AccuSign MET as well as AMP, and others. The sensitivity of MET detected by instrumental analyses was 88.8% (40/45), with a specificity of 100% (70/70). Investigation B:The results were classified into positive for AccuSign MET as well as AMP, and others. The sensitivity of MET detected by instrumental analyses was 80.0% (4/5), with a specificity of 100% (11/11). A definite diagnosis of methamphetamine intoxication would be possible without using instrumental analyses when both AccuSign MET and AMP are positive.

  8. Exponential Stabilization of an Underactuated Surface Vessel

    Directory of Open Access Journals (Sweden)

    Kristin Y. Pettersen

    1997-07-01

    Full Text Available The paper shows that a large class of underactuated vehicles cannot be asymptotically stabilized by either continuous or discontinuous state feedback. Furthermore, stabilization of an underactuated surface vessel is considered. Controllability properties of the surface vessels is presented, and a continuous periodic time-varying feedback law is proposed. It is shown that this feedback law exponentially stabilizes the surface vessel to the origin, and this is illustrated by simulations.

  9. Ocean Station Vessel

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Ocean Station Vessels (OSV) or Weather Ships captured atmospheric conditions while being stationed continuously in a single location. While While most of the...

  10. 32 CFR 150.6 - Signing of papers.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 1 2010-07-01 2010-07-01 false Signing of papers. 150.6 Section 150.6 National... JUSTICE COURTS OF CRIMINAL APPEALS RULES OF PRACTICE AND PROCEDURE § 150.6 Signing of papers. All formal papers shall be signed and shall show, typewritten or printed, the signer's name, address, military grade...

  11. From gesture to sign language: conventionalization of classifier constructions by adult hearing learners of British Sign Language.

    Science.gov (United States)

    Marshall, Chloë R; Morgan, Gary

    2015-01-01

    There has long been interest in why languages are shaped the way they are, and in the relationship between sign language and gesture. In sign languages, entity classifiers are handshapes that encode how objects move, how they are located relative to one another, and how multiple objects of the same type are distributed in space. Previous studies have shown that hearing adults who are asked to use only manual gestures to describe how objects move in space will use gestures that bear some similarities to classifiers. We investigated how accurately hearing adults, who had been learning British Sign Language (BSL) for 1-3 years, produce and comprehend classifiers in (static) locative and distributive constructions. In a production task, learners of BSL knew that they could use their hands to represent objects, but they had difficulty choosing the same, conventionalized, handshapes as native signers. They were, however, highly accurate at encoding location and orientation information. Learners therefore show the same pattern found in sign-naïve gesturers. In contrast, handshape, orientation, and location were comprehended with equal (high) accuracy, and testing a group of sign-naïve adults showed that they too were able to understand classifiers with higher than chance accuracy. We conclude that adult learners of BSL bring their visuo-spatial knowledge and gestural abilities to the tasks of understanding and producing constructions that contain entity classifiers. We speculate that investigating the time course of adult sign language acquisition might shed light on how gesture became (and, indeed, becomes) conventionalized during the genesis of sign languages. Copyright © 2014 Cognitive Science Society, Inc.

  12. Persistent Mullerian duct syndrome in a Miniature Schnauzer dog with signs of feminization and a Sertoli cell tumour.

    Science.gov (United States)

    Vegter, A R; Kooistra, H S; van Sluijs, F J; van Bruggen, L W L; Ijzer, J; Zijlstra, C; Okkens, A C

    2010-06-01

    A 5-year-old male Miniature Schnauzer was presented with unilateral cryptorchidism and signs of feminization. Abdominal ultrasonography revealed an enlarged right testis and a large, fluid-filled cavity that appeared to arise from the prostate. Computed tomography revealed the cavity to be consistent with an enlarged uterine body, arising from the prostate, and showed two structures resembling uterine horns that terminated close to the adjacent testes. The dog had a normal male karyotype, 78 XY. Gonadohysterectomy was performed and both the surgical and the histological findings confirmed the presence of a uterus in this male animal, resulting in a diagnosis of persistent Mullerian duct syndrome (PMDS). The enlarged intra-abdominal testis contained a Sertoli cell tumour. Computed tomography proved to be an excellent diagnostic tool for PMDS.

  13. Superior long term outcome associated with native vessel versus graft vessel PCI following secondary PCI in patients with prior CABG.

    Science.gov (United States)

    Mavroudis, Chrysostomos A; Kotecha, Tushar; Chehab, Omar; Hudson, Jonathan; Rakhit, Roby D

    2017-02-01

    Secondary percutaneous coronary intervention (PCI) in patients with prior coronary artery bypass graft surgery is increasingly common. Graft vessel PCI has higher rates of adverse events compared with native coronary vessel PCI. To investigate the clinical outcomes of patients with prior CABG who underwent secondary PCI of either a graft vessel (GV), a native coronary vessel (NV) or both graft and native (NG) vessels. 220 patients (84% male) who underwent PCI in our institution to either GV (n=89), NV (n=103) or both GV and NV (NG group) (n=28) were studied. The study population underwent 378 procedures (GV group; n=126, NV group; n=164 and NG group; n=88). Median follow up was for 36months [range 2-75months]. Target vessel revascularisation (TVR) occurred in 12.5% of the GV group and 3.6% in the NV group [p=0.0004], and was predominantly due to in-stent restenosis. Patients who had PCI due to TVR were more likely to suffer from diabetes and peripheral vascular disease. History of chronic renal failure was associated with higher risk (HR 2.21, p=0.005) whereas preserved left ventricular ejection fraction (LVEF) with lower risk (HR 0.17, p=0.0007) of death. The median survival (interval between CABG and end of follow-up period) was lower in the GV compared with the NV group (315 vs 372months p=0.005). This registry demonstrates inferior long term outcome for patients undergoing secondary PCI of GV versus NV. Where possible, a strategy of NV rather than GV target PCI should be considered in patients with prior CABG. Secondary PCI in patients with prior CABG surgery is increasingly common. Graft vessel PCI has inferior outcomes with high rates of restenosis and occlusion compared with native coronary vessel PCI. We studied the clinical outcomes of 220 patients with prior CABG who underwent secondary PCI to either a graft vessel (GV), a native coronary vessel (NV) or both graft and native (NG) vessels. Target vessel revascularisation was 5 times higher in the GV

  14. Signing Earth Science: Accommodations for Students Who Are Deaf or Hard of Hearing and Whose First Language Is Sign

    Science.gov (United States)

    Vesel, J.; Hurdich, J.

    2014-12-01

    TERC and Vcom3D used the SigningAvatar® accessibility software to research and develop a Signing Earth Science Dictionary (SESD) of approximately 750 standards-based Earth science terms for high school students who are deaf and hard of hearing and whose first language is sign. The partners also evaluated the extent to which use of the SESD furthers understanding of Earth science content, command of the language of Earth science, and the ability to study Earth science independently. Disseminated as a Web-based version and App, the SESD is intended to serve the ~36,000 grade 9-12 students who are deaf or hard of hearing and whose first language is sign, the majority of whom leave high school reading at the fifth grade or below. It is also intended for teachers and interpreters who interact with members of this population and professionals working with Earth science education programs during field trips, internships etc. The signed SESD terms have been incorporated into a Mobile Communication App (MCA). This App for Androids is intended to facilitate communication between English speakers and persons who communicate in American Sign Language (ASL) or Signed English. It can translate words, phrases, or whole sentences from written or spoken English to animated signing. It can also fingerspell proper names and other words for which there are no signs. For our presentation, we will demonstrate the interactive features of the SigningAvatar® accessibility software that support the three principles of Universal Design for Learning (UDL) and have been incorporated into the SESD and MCA. Results from national field-tests will provide insight into the SESD's and MCA's potential applicability beyond grade 12 as accommodations that can be used for accessing the vocabulary deaf and hard of hearing students need for study of the geosciences and for facilitating communication about content. This work was funded in part by grants from NSF and the U.S. Department of Education.

  15. Dictionaries of African Sign Languages: An Overview

    Science.gov (United States)

    Schmaling, Constanze H.

    2012-01-01

    This article gives an overview of dictionaries of African sign languages that have been published to date most of which have not been widely distributed. After an introduction into the field of sign language lexicography and a discussion of some of the obstacles that authors of sign language dictionaries face in general, I will show problems…

  16. Analyzing Vessel Behavior Using Process Mining

    NARCIS (Netherlands)

    Maggi, F.M.; Mooij, A.J.; Aalst, W.M.P. van der

    2013-01-01

    In the maritime domain, electronic sensors such as AIS receivers and radars collect large amounts of data about the vessels in a certain geographical area. We investigate the use of process mining techniques for analyzing the behavior of the vessels based on these data. In the context of maritime

  17. 2011 Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  18. 2013 Vessel Density

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Automatic Identification Systems (AIS) are a navigation safety device that transmits and monitors the location and characteristics of many vessels in U.S. and...

  19. Design and construction of the prestressed concrete boiler closures for the Hartlepool and Heysham pressure vessels

    International Nuclear Information System (INIS)

    Crowder, R.; Howells, R.M.; Paton, A.A.

    1976-01-01

    At a relatively late stage in the station design, the boiler closures for the reactor vessels at Hartlepool and Heysham were changed from steel to prestressed concrete. This paper sets out the criteria which were finally evolved for the new style of closure and describes the way in which the prestressed concrete closure's parts were designed to satisfy these criteria. With both the civil and mechanical components of the closure having their own specific requirements, close co-operation was necessary between these disciplines to ensure that a compatible and practical closure design resulted. This close interrelationship has been carried through into the construction stage and a special concreting and prestressing factory has been built adjacent to the works of the mechanical component fabricator. This enabled an optimum manufacturing cycle to be followed and the important aspects of this are described in the paper. (author)

  20. A Study on Guide Sign Validity in Driving Simulator

    Directory of Open Access Journals (Sweden)

    Wei Zhonghua

    2011-12-01

    Full Text Available The role of guide sign to inform road user about the information of network is important. How to design and locate guide sign to increase traffic operation efficiency is a key point for traffic engineers. Driving simulator is useful devised to study guide sign in the process and system control. For the purpose of studying guide signs using the tool of driving simulator, guide sign's validity in driving simulator was studied. Results of this experiment are the foundation of further study on guide sign. Simulator calibration procedure for guide sign was set up in this study. Legibility distance as measure of performance was used to evaluate the validity of guide sign in driving simulator. Thirty two participants were recruited. Results indicated legibility distance and speed were inversely related with the method of data mining. Legibility distance and text height of guide sign were positive related. When speed is 20km/h, 30km/h, 40km/h, magnifying power of text height is 4.3, 4.1, 3.8, while guide signs are absolute validity in driving simulator.

  1. A rare sign of ischemia during exercise ECG: PR interval lengthening in the recovery period.

    Science.gov (United States)

    Durakoğlugil, Murtaza Emre; Kocaman, Sinan Altan; Ciçek, Yüksel; Cetin, Mustafa

    2012-12-01

    Exercise electrocardiography (ECG) is one of the most commonly utilized tests in cardiology. Despite the drawbacks, exercise ECG is widely preferred due to low cost, standardization, and strong prognostic information. A prolonged PR interval during recovery has recently been proposed as an indicator of mortality. Herein, we report an interesting case of a patient who presented with the complaint of exertional dyspnea and exhibited PR lengthening during the recovery period on the exercise ECG. The patient had a PR interval of 240 ms before exercise, which decreased to 160 ms at peak stress. However, during recovery, the PR interval prolonged gradually, reaching 320 ms at the second minute and persisting at that length until the end of the recovery period. The patient achieved 87% of the age predicted maximum heart rate, and experienced non-disabling shortness of breath and a pressure sensation in the chest, with no apparent ST segment depression. Recovery parameters, including heart rate recovery and systolic blood pressure recovery, were also within normal limits. The patient underwent coronary angiography with the suspicion of CAD which revealed severe multi-vessel disease. This rare case emphasizes the importance of PR lengthening in the recovery period as a sign of severe ischemia, in addition to other signs, such as prominent ST-segment changes, chronotropic incompetence, impaired hemodynamic response, and poor exercise capacity during stress ECG evaluation.

  2. fMRI Evidence of Acupoints Specificity in Two Adjacent Acupoints

    Directory of Open Access Journals (Sweden)

    Hua Liu

    2013-01-01

    Full Text Available Objectives. Acupoint specificity is the foundation of acupuncture treatment. The aim of this study is to investigate whether the acupoint specificity exists in two adjacent acupoints. Design and Setting. Two adjacent real acupoints, LR3 (Taichong and ST44 (Neiting, and a nearby nonacupoint were selected. Thirty-three health volunteers were divided into three groups in random order, and each group only received acupuncture at one of the three points. While they received acupuncture, fMRI scan was performed. Results. The common cerebral activated areas responding to LR3 and ST44 included the contralateral primary somatosensory area (SI and ipsilateral cerebellum. Acupuncture at LR3 specifically activated contralateral middle occipital gyrus, ipsilateral medial frontal gyrus, superior parietal lobe, middle temporal gyrus, rostral anterior cingulate cortex (rACC, lentiform nucleus, insula, and contralateral thalamus. Stimulation at ST44 selectively activated ipsilateral secondary somatosensory area (SII, contralateral middle frontal gyrus, inferior frontal gyrus, lingual gyrus, lentiform nucleus, and bilateral posterior cingulate cortex (PCC. Conclusions. Acupuncture at adjacent acupoints elicits distinct cerebral activation patterns, and those specific patterns might be involved in the mechanism of the specific therapeutic effects of different acupoints.

  3. Using BRDFs for accurate albedo calculations and adjacency effect corrections

    Energy Technology Data Exchange (ETDEWEB)

    Borel, C.C.; Gerstl, S.A.W.

    1996-09-01

    In this paper the authors discuss two uses of BRDFs in remote sensing: (1) in determining the clear sky top of the atmosphere (TOA) albedo, (2) in quantifying the effect of the BRDF on the adjacency point-spread function and on atmospheric corrections. The TOA spectral albedo is an important parameter retrieved by the Multi-angle Imaging Spectro-Radiometer (MISR). Its accuracy depends mainly on how well one can model the surface BRDF for many different situations. The authors present results from an algorithm which matches several semi-empirical functions to the nine MISR measured BRFs that are then numerically integrated to yield the clear sky TOA spectral albedo in four spectral channels. They show that absolute accuracies in the albedo of better than 1% are possible for the visible and better than 2% in the near infrared channels. Using a simplified extensive radiosity model, the authors show that the shape of the adjacency point-spread function (PSF) depends on the underlying surface BRDFs. The adjacency point-spread function at a given offset (x,y) from the center pixel is given by the integral of transmission-weighted products of BRDF and scattering phase function along the line of sight.

  4. Models and Algorithms for Container Vessel Stowage Optimization

    DEFF Research Database (Denmark)

    Delgado-Ortegon, Alberto

    .g., selection of vessels to buy that satisfy specific demands), through to operational decisions (e.g., selection of containers that optimize revenue, and stowing those containers into a vessel). This thesis addresses the question of whether it is possible to formulate stowage optimization models...... container of those to be loaded in a port should be placed in a vessel, i.e., to generate stowage plans. This thesis explores two different approaches to solve this problem, both follow a 2-phase decomposition that assigns containers to vessel sections in the first phase, i.e., master planning...

  5. Sealing analysis for nuclear vessels of PWR

    International Nuclear Information System (INIS)

    Qu Jiadi; Dou Yikang

    1988-01-01

    The fundamental equations of sealing analysis for vessels are given and a computer program named SMEC, which considers the change of stud loading, the elastic contact between flange mating surfaces and the transient thermal effects, is developed accordingly. The SMEC is verified by several test. On the basis of analysis, a new concept of classifying vessels into three types according to increasing or decreasing of bolt loading with increasing pressure is suggested. Type-A vessel is that in which the bolt loading increases monotonically with increasing pressure, while in type-B, the bolt loading decreases monotonically, and in type-C, the bolt loading changes nonmonotonically. It is important for vessel design to distinguish the types through analysis. The sealing mechanism is also discussed

  6. Method to moor an offshore operating vessel

    Energy Technology Data Exchange (ETDEWEB)

    Flory, J.F.

    1983-01-24

    A vessel such as a storage vessel is permanently moored, by means such as a yoke pivoted on the forecastle of the vessel, to a mooring leg, e.g. a riser or anchor chain, which is attached to a base located on the ocean floor. Mounted on the vessel is tension exsisting means, for example, counterweights, springs, winches, or the like, operably connected with the mooring leg for applying tension thereto such as by lifting the yoke. The top of the mooring leg is connected to the end of the yoke through a mooring swivel and a gimbaled mooring table or a universal joint. A fluid swivel may be located above the mooring table or about a load-carrying shaft connected to the mooring leg. 8 drawings.

  7. MRA of fibromuscular dysplasia in cervical vessels

    International Nuclear Information System (INIS)

    Link, J.; Steffens, J.C.; Mueller-Huelsbeck, S.; Brossmann, J.; Heller, M.

    1996-01-01

    In 386 selective angiograms of cervical vessels fibromuscular dysplasia was revealed in 4 female patients in the age of 30-54 years. FMD was located in the carotid artery (n=5) and in the vertebral artery (n=2) with a total of 8 lesions. 6/8 of the lesions of the seven cervical vessels were located typically in the mid cervical portion of the vessels and 2/6 lesions were located in the atlas loop of the vertebral artery. 4 lesions showed moderate stenosis and 4 vessels showed only mild stenosis. These patterns which demonstrated the typical morphology of fibromuscular dysplasia with alternating irregular zones of widening and narrowing were evaluated well with MR angiography, the others were missed. (orig./MG) [de

  8. Retinal Vessels Segmentation Techniques and Algorithms: A Survey

    Directory of Open Access Journals (Sweden)

    Jasem Almotiri

    2018-01-01

    Full Text Available Retinal vessels identification and localization aim to separate the different retinal vasculature structure tissues, either wide or narrow ones, from the fundus image background and other retinal anatomical structures such as optic disc, macula, and abnormal lesions. Retinal vessels identification studies are attracting more and more attention in recent years due to non-invasive fundus imaging and the crucial information contained in vasculature structure which is helpful for the detection and diagnosis of a variety of retinal pathologies included but not limited to: Diabetic Retinopathy (DR, glaucoma, hypertension, and Age-related Macular Degeneration (AMD. With the development of almost two decades, the innovative approaches applying computer-aided techniques for segmenting retinal vessels are becoming more and more crucial and coming closer to routine clinical applications. The purpose of this paper is to provide a comprehensive overview for retinal vessels segmentation techniques. Firstly, a brief introduction to retinal fundus photography and imaging modalities of retinal images is given. Then, the preprocessing operations and the state of the art methods of retinal vessels identification are introduced. Moreover, the evaluation and validation of the results of retinal vessels segmentation are discussed. Finally, an objective assessment is presented and future developments and trends are addressed for retinal vessels identification techniques.

  9. Sharing Vital Signs between mobile phone applications.

    Science.gov (United States)

    Karlen, Walter; Dumont, Guy A; Scheffer, Cornie

    2014-01-01

    We propose a communication library, ShareVitalSigns, for the standardized exchange of vital sign information between health applications running on mobile platforms. The library allows an application to request one or multiple vital signs from independent measurement applications on the Android OS. Compatible measurement applications are automatically detected and can be launched from within the requesting application, simplifying the work flow for the user and reducing typing errors. Data is shared between applications using intents, a passive data structure available on Android OS. The library is accompanied by a test application which serves as a demonstrator. The secure exchange of vital sign information using a standardized library like ShareVitalSigns will facilitate the integration of measurement applications into diagnostic and other high level health monitoring applications and reduce errors due to manual entry of information.

  10. Sleeping sickness surveys: game reserve adjacent villages in Malawi

    African Journals Online (AJOL)

    Sleeping sickness surveys: game reserve adjacent villages in Malawi. ... Sera from 160 game ranger volunteers and from 82 suspected cases_of Rhodesian sleeping sickness were tested by use of ELISA, ... AJOL African Journals Online.

  11. Three Dimensional Shallow Water Adaptive Hydraulics (ADH-SW3): Waterborne Vessels

    Science.gov (United States)

    2015-10-01

    Type Value Description 1 char CBOW Card type 2 int > 0 Vessel number 3 real # Ratio of vessel bow to vessel draft CSTR FRACTION OF DRAFT...APPLIED TO PSTR Field Type Value Description 1 char CSTR Card type 2 int > 0 Vessel number 3 real # Ratio of vessel stern to vessel draft PROP

  12. Hepatic dimple sign on CT

    International Nuclear Information System (INIS)

    Matsumoto, Kunihiko; Nakajima, Teiichi; Ishikawa, Nobuyoshi; Ebihara, Reiko; Saida, Yukihisa

    1983-01-01

    The ''Dimple sign'' has been coined by Baltaxe et al. in 1974 and was said to be useful angiographic sign of avascular tumor. Similar dimple can be seen in the margin of the liver on CT examination of the hepatic tumors. We called this hepatic dimple sign and its clinical usefulness on CT examination was studied with 133 cases of hepatic tumors. Among 133 cases, there were 68 cases of hepatocellular carcinoma, 57 cases of metastatic liver tumor, 5 cases of hemangioma of the liver and 3 cases of hepatoblastoma. Hepatic dimple sign was recognized on 2 cases of metastatic liver tumor, 1 case of hemangioma, and 1 case of carcinoma of the gallbladder with hepatic infiltration. Cases experienced in the affiliated hospitals were also studied. A case of hepatocellular carcinoma and a case of metastatic liver tumor were evaluated. These tumors were relativly large measuring over 5cm in the greatest diameter and low density areas were apparent on plain CT. Therefore, dimples in the hepatic margin seen in CT scan did not contribute to the diagnostic accuracy of the liver tumor in these cases. (author)

  13. Hepatic dimple sign on CT

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, Kunihiko; Nakajima, Teiichi; Ishikawa, Nobuyoshi; Ebihara, Reiko; Saida, Yukihisa

    1983-06-01

    The ''Dimple sign'' has been coined by Baltaxe et al. in 1974 and was said to be useful angiographic sign of avascular tumor. Similar dimple can be seen in the margin of the liver on CT examination of the hepatic tumors. We called this hepatic dimple sign and its clinical usefulness on CT examination was studied with 133 cases of hepatic tumors. Among 133 cases, there were 68 cases of hepatocellular carcinoma, 57 cases of metastatic liver tumor, 5 cases of hemangioma of the liver and 3 cases of hepatoblastoma. Hepatic dimple sign was recognized on 2 cases of metastatic liver tumor, 1 case of hemangioma, and 1 case of carcinoma of the gallbladder with hepatic infiltration. Cases experienced in the affiliated hospitals were also studied. A case of hepatocellular carcinoma and a case of metastatic liver tumor were evaluated. These tumors were relativly large measuring over 5cm in the greatest diameter and low density areas were apparent on plain CT. Therefore, dimples in the hepatic margin seen in CT scan did not contribute to the diagnostic accuracy of the liver tumor in these cases. (author).

  14. Roi Detection and Vessel Segmentation in Retinal Image

    Science.gov (United States)

    Sabaz, F.; Atila, U.

    2017-11-01

    Diabetes disrupts work by affecting the structure of the eye and afterwards leads to loss of vision. Depending on the stage of disease that called diabetic retinopathy, there are sudden loss of vision and blurred vision problems. Automated detection of vessels in retinal images is a useful study to diagnose eye diseases, disease classification and other clinical trials. The shape and structure of the vessels give information about the severity of the disease and the stage of the disease. Automatic and fast detection of vessels allows for a quick diagnosis of the disease and the treatment process to start shortly. ROI detection and vessel extraction methods for retinal image are mentioned in this study. It is shown that the Frangi filter used in image processing can be successfully used in detection and extraction of vessels.

  15. Power reactor pressure vessel benchmarks

    International Nuclear Information System (INIS)

    Rahn, F.J.

    1978-01-01

    A review is given of the current status of experimental and calculational benchmarks for use in understanding the radiation embrittlement effects in the pressure vessels of operating light water power reactors. The requirements of such benchmarks for application to pressure vessel dosimetry are stated. Recent developments in active and passive neutron detectors sensitive in the ranges of importance to embrittlement studies are summarized and recommendations for improvements in the benchmark are made. (author)

  16. Commissioning result of the KSTAR in-vessel cryo-pump

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Y. B.; Lee, H. J.; Park, Y.M. [National Fusion Research Institute, Daejeon (Korea, Republic of); and others

    2013-12-15

    KSTAR in-vessel cryo-pump has been installed in the vacuum vessel top and bottom side with up-down symmetry for the better plasma density control in the D-shape H-mode. The cryogenic helium lines of the in-vessel cryo-pump are located at the vertical positions from the vacuum vessel torus center 2,000 mm. The inductive electrical potential has been optimized to reduce risk of electrical breakdown during plasma disruption. In-vessel cryo-pump consists of three parts of coaxial circular shape components; cryo-panel, thermal shield and particle shield. The cryo-panel is cooled down to below 4.5 K. The cryo-panel and thermal shields were made by Inconel 625 tube for higher mechanical strength. The thermal shields and their cooling tubes were annealed in air environment to improve the thermal radiation emissivity on the surface. Surface of cryo-panel was electro-polished to minimize the thermal radiation heat load. The in-vessel cryo-pump was pre-assembled on a test bed in 180 degree segment base. The leak test was carried out after the thermal shock between room temperature to LN2 one before installing them into vacuum vessel. Two segments were welded together in the vacuum vessel and final leak test was performed after the thermal shock. Commissioning of the in-vessel cryo-pump was carried out using a temporary liquid helium supply system.

  17. Vessel eddy current characteristics in SST-1 tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Jana, Subrata; Pradhan, Subrata, E-mail: pradhan@ipr.res.in; Dhongde, Jasraj; Masand, Harish

    2016-11-15

    Highlights: • Eddy current distribution in the SST-1 vacuum vessel. • Circuit model analysis of eddy current. • A comparison of the field lines with and without the plasma column in identical conditions. • The influence of eddy current in magnetic NULL dynamics. - Abstract: Eddy current distribution in the vacuum vessel of the Steady state superconducting (SST-1) tokamak has been determined from the experimental data obtained using an array of internal voltage loops (flux loop) installed inside the vacuum vessel. A simple circuit model has been employed. The model takes into account the geometric and constructional features of SST-1 vacuum vessel. SST-1 vacuum vessel is a modified ‘D’ shaped vessel having major axis of 1.285 m and minor axis of 0.81 m and has been manufactured from non-magnetic stainless steel. The Plasma facing components installed inside the vacuum vessel are graphite blocks mounted on Copper Chromium Zirconium (CuCrZr) heat sink plates on inconel supports. During discharge of the central solenoid, eddy currents get generated in the vacuum vessel and passive supports on it. These eddy currents influence the early magnetic NULL dynamics and plasma break-down and start-up characteristics. The computed results obtained from the model have been benchmarked against experimental data obtained in large number of SST-1 plasma shots. The results are in good agreement. Once bench marked, the calculated eddy current based on flux loop signal and circuit equation model has been extended to the reconstruction of the overall B- field contours of SST-1 tokamak in the vessel region. A comparison of the field lines with and without the plasma column in identical conditions of the central solenoid and equilibrium field profiles has also been done with an aim to quantify the diagnostics responses in vacuum shots.

  18. CDC Vital Signs-Preventing Stroke Deaths

    Centers for Disease Control (CDC) Podcasts

    This podcast is based on the September 2017 CDC Vital Signs report. Each year, more than 140,000 people die and many survivors face disability. Eighty percent of strokes are preventable. Learn the signs of stroke and how to prevent them.

  19. Foundamental characteristics of layered pressure vessel

    International Nuclear Information System (INIS)

    Moriwaki, Yoshikazu; Fugino, Masayuki; Shimizu, Yasuhiro; Nakamura, Takeshi

    1978-01-01

    Pressure vessels become larger and the working pressure become higher with the remarkable development of petroleum, chemical, thermal power generation and atomic energy industries. Multi-layered pressure vessels can be manufactured cheaply without large installations, and large wall thickness can be made, therefore they are suitable for large pressure vessels. The stress and deformation behaviors of such vessels are very complex because of the effect of frictional force working between layers. In this study, the phenomena arising in multiple layers and the difference as compared with single wall were studied fundamentally as one step for analyzing multi-layered pressure vessels as a whole. Finite element technique was employed as the analyzing method, and the behavior of multiple layers was analyzed, regarding it as multiple contact problem. The behavior of multiple layers seems to appear conspicuously in case of bending load, therefore the basic characteristics regarding bending were examined. The evaluation of interfacial stiffness was carried out by experiment. The computer program for analyzing multiple contact problem was developed. In order to examine the validity of the program, comparison with the analytical solution heretofore and the result of calculation by finite element technique was carried out. Moreover, the experimental proof with multi-layered models was made. The frictional force between layers hardly contributes to the stiffness. (Kako, I.)

  20. 46 CFR 115.812 - Pressure vessels and boilers.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Pressure vessels and boilers. 115.812 Section 115.812... CERTIFICATION Material Inspections § 115.812 Pressure vessels and boilers. (a) Pressure vessels must be tested... testing requirements for boilers are contained in § 61.05 in subchapter F of this chapter. [CGD 85-080, 61...