WorldWideScience

Sample records for adding subtracting multiplying

  1. Tomography of photon-added and photon-subtracted states

    NARCIS (Netherlands)

    Bazrafkan, MR; Man'ko, [No Value

    The purpose of this paper is to introduce symplectic and optical tomograms of photon-added and photon-subtracted quantum states. Explicit relations for the tomograms of photon-added and photon-subtracted squeezed coherent states and squeezed number states are obtained. Generating functions for the

  2. New holographic limit of AdS5(multiply-in-circle sign)S5

    International Nuclear Information System (INIS)

    Hatsuda, Machiko; Siegel, Warren

    2003-01-01

    We reexamine the projective light cone limit of the gauge-invariant Green-Schwarz action on five-dimensional anti-de Sitter (multiply-in-circle sign) the five-sphere. It implies the usual holography for AdS 5 , but also (a complex) one for S 5 . The result is N=4 projective superspace, which unlike N=4 harmonic superspace can describe N=4 super Yang-Mills theory off shell

  3. Ad Hoc Microphone Array Beamforming Using the Primal-Dual Method of Multipliers

    DEFF Research Database (Denmark)

    Tavakoli, Vincent Mohammad; Jensen, Jesper Rindom; Heusdens, Richard

    2016-01-01

    In the recent years, there have been increasing amount of researches aiming at optimal beamforming with ad hoc microphone arrays, mostly with fusion-based schemes. However, huge amount of computational complexity and communication overhead impede many of these algorithms from being useful in prac...... the distributed linearly-constrained minimum variance beamformer using the the state of the art primal-dual method of multipliers. We study the proposed algorithm with an experiment....

  4. Updates to Constituent Subtraction in Heavy Ions at CMS

    CERN Document Server

    CMS Collaboration

    2018-01-01

    The latest upgrades and performance of constituent subtraction in 5.02 TeV PbPb collisions is presented. The constituent subtraction is extended through the full tracker acceptance, increasing the rapidity reach of correctly subtracted jets. A modulation in azimuthal angle is added to the subtraction, accounting for flow on an event-by-event basis and improving jet energy resolution. Closure of jet energy scale after corrections and jet energy resolution is shown for R=0.4 and R=0.8 jets, the latter for the first time in CMS Heavy-Ions.

  5. A method for subtraction of the extrarenal 'background' in dynamic 131I-hippurate renoscintigraphy

    International Nuclear Information System (INIS)

    Mlodkowska, E.; Liniecki, J.; Surma, M.

    1979-01-01

    Using a Toshiba GC-401 gamma camera with MDS computer Trinary a new method was developed for subtracting the extrarenal (extracanalicular) 'background' from the count rate recorded over the kidneys after intravenous administration of 131 I-hippurate. Mean subtraction factors of the 'blood' activity curve were calculated from a study of 27 patients who were given 51 Cr-HSA for purposes of conventional renography with 'background' subtraction. The values of the mean subtraction factors anti Fsub(R,L) for the right and left kidney, by which a blood count rate should be multiplied amounted to 0.86 +- 0.12 and 0.79 +- 0.13, respectively. A comparison of the coefficients of variation of the pure renal signal when mean vs. individually determined subtraction factors were used, and the verification of the method in unilaterally nephrectomized patients have demonstrated that determination of the factors, anti Fsub(R,L), for each patient individually is not required and sufficient precision can be obtained by using the method and factors reported in this study. (orig.) [de

  6. Novel subtractive transcription-based amplification of mRNA (STAR method and its application in search of rare and differentially expressed genes in AD brains

    Directory of Open Access Journals (Sweden)

    Walker P Roy

    2006-11-01

    Full Text Available Abstract Background Alzheimer's disease (AD is a complex disorder that involves multiple biological processes. Many genes implicated in these processes may be present in low abundance in the human brain. DNA microarray analysis identifies changed genes that are expressed at high or moderate levels. Complementary to this approach, we described here a novel technology designed specifically to isolate rare and novel genes previously undetectable by other methods. We have used this method to identify differentially expressed genes in brains affected by AD. Our method, termed Subtractive Transcription-based Amplification of mRNA (STAR, is a combination of subtractive RNA/DNA hybridization and RNA amplification, which allows the removal of non-differentially expressed transcripts and the linear amplification of the differentially expressed genes. Results Using the STAR technology we have identified over 800 differentially expressed sequences in AD brains, both up- and down- regulated, compared to age-matched controls. Over 55% of the sequences represent genes of unknown function and roughly half of them were novel and rare discoveries in the human brain. The expression changes of nearly 80 unique genes were further confirmed by qRT-PCR and the association of additional genes with AD and/or neurodegeneration was established using an in-house literature mining tool (LitMiner. Conclusion The STAR process significantly amplifies unique and rare sequences relative to abundant housekeeping genes and, as a consequence, identifies genes not previously linked to AD. This method also offers new opportunities to study the subtle changes in gene expression that potentially contribute to the development and/or progression of AD.

  7. Digital subtraction angiography in patients with central vertigo

    International Nuclear Information System (INIS)

    Inamori, Toru; Takayasu, Yukio; Umetani, Yoshio; Taruoka, Akinori.

    1985-01-01

    Digital subtraction angiography (DSA) is a recently developed non-invasive intravenous angiography which has become possible through real time digital subtraction of x-ray transmission data from an image intensifier and television system. The output signals of the image intensifier-television camera system are digitized by an analog-digital converter. The digital information, 512x512 pixels and 9 bits deep, is fed into the image processing assembly after logarithmic amplification, where 2-8 frames are added and subtracted from mask images for the final digital images. Intravenous digital subtraction angiography was performed in 21 patients with intractable dizzy spells of central origin resistant to treatment. These patients showed some signs of CNS disturbance, although there were no significant findings on CT scans. Surprisingly, findings were abnormal in 14 of 21 patients (66.7%). DSA is, therefore, considered to be an important aid in the diagnosis of vertigo of the central type. (J.P.N.)

  8. A comparison of subtracted images from dental subtraction programs

    International Nuclear Information System (INIS)

    Han, Won Jeong

    2002-01-01

    To compare the standard deviation of gray levels on digital subtracted images obtained by different dental subtraction programs. Paired periapical films were taken at the lower premolar and molar areas of the phantoms involving human mandible. The bite registration group used Rinn XCP equipment and bite registration material, based on polyvinyl siloxane, for standardization. The no bite registration group used only Rinn XCP equipment. The periapical film images were digitized at 1200 dpi resolution and 256 gray levels by a flat bed scanner with transparency unit. Dental digital subtraction programs used for this study were Subtractor (Biomedisys Co., Korea) and Emago (Oral Diagnostic Systems, The Netherlands). To measure the similarities between the subtracted images, the standard deviations of the gray levels were obtained using a histogram of subtracted images, which were then analyzed statistically. Subtracted images obtained by using the Emago program without manual selection of corresponding points showed the lowest standard deviation of gray levels (p<0.01). And the standard deviation of gray levels was lower in subtracted images in the group of a bite registration than in the group of no use of bite registration (p<0.01). Digital radiographic subtraction without manual selection of reference points was found to be a convenient and superior method.

  9. Subtractive Leadership

    Science.gov (United States)

    Larwin, K. H.; Thomas, Eugene M.; Larwin, David A.

    2015-01-01

    This paper introduces a new term and concept to the leadership discourse: Subtractive Leadership. As an extension of the distributive leadership model, the notion of subtractive leadership refers to a leadership style that detracts from organizational culture and productivity. Subtractive leadership fails to embrace and balance the characteristics…

  10. Evaluation of multiplier effect of housing investments in the city economy

    Science.gov (United States)

    Ovsiannikova, T.; Rabtsevich, O.; Yugova, I.

    2017-01-01

    The given study presents evaluation of the role and significance of housing investments providing stable social and economic development of a city. It also justifies multiplier impact of investments in housing construction on all the sectors of urban economy. Growth of housing investments generates multiplier effect triggering the development of other different interrelated sectors. The paper suggests approach developed by the authors to evaluate the level of city development. It involves defining gross city product on the basis of integral criterion of gross value added of types of economic activities in the city economy. The algorithm of gross value added generation in urban economy is presented as a result of multiplier effect of housing investments. The evaluation of the mentioned effect was shown on the case of the city of Tomsk (Russia). The study has revealed that multiplier effect allows obtaining four rubles of added value out of one ruble of housing investments in the city economy. Methods used in the present study include the ones of the System of National Accounts, as well as methods of statistical and structural analysis. It has been proved that priority investment in housing construction is considered to be the key factor for stable social and economic development of the city. Developed approach is intended for justification of priority directions in municipal and regional investment policy. City and regional governing bodies and potential investors are the ones to apply the given approach.

  11. Tourism multipliers in the Mexican economy

    Directory of Open Access Journals (Sweden)

    Antonio Kido-Cruz

    2016-12-01

    Full Text Available This paper presents an analysis of the multiplier impact generated by the tourism sector in Mexico in the year 2013. The importance of studying this sector, in particular, lies in its contribution to the National GDP of over 8% and in its promising development based on services’ quality and the preferred destination of the developed countries. In addition, it is proposed to simulate the multiplier impact that will generate two current events, as they are, the construction of the new International Airport of Mexico and the increase of the investment in Fibers. The results were very punctual, a better distribution of the investment is generated, it is invested in the tourism sector, mainly in variables such as value added and remuneration.

  12. Dark energy from modified gravity with Lagrange multipliers

    International Nuclear Information System (INIS)

    Capozziello, Salvatore; Matsumoto, Jiro; Nojiri, Shin'ichi; Odintsov, Sergei D.

    2010-01-01

    We study scalar-tensor theory, k-essence and modified gravity with Lagrange multiplier constraint which role is to reduce the number of degrees of freedom. Dark Energy cosmology of different types (ΛCDM, unified inflation with DE, smooth non-phantom/phantom transition epoch) is reconstructed in such models. It is demonstrated that presence of Lagrange multiplier simplifies the reconstruction scenario. It is shown that mathematical equivalence between scalar theory and F(R) gravity is broken due to presence of constraint. The cosmological evolution is defined by the second F 2 (R) function dictated by the constraint. The convenient F(R) gravity sector is relevant for local tests. This opens the possibility to make originally non-realistic theory to be viable by adding the corresponding constraint. A general discussion on the role of Lagrange multipliers to make higher-derivative gravity canonical is developed.

  13. An Application of Multiplier Analysis in Analyzing the Role of Mining Sectors on Indonesian National Economy

    Science.gov (United States)

    Subanti, S.; Hakim, A. R.; Hakim, I. M.

    2018-03-01

    This purpose of the current study aims is to analyze the multiplier analysis on mining sector in Indonesia. The mining sectors defined by coal and metal; crude oil, natural gas, and geothermal; and other mining and quarrying. The multiplier analysis based from input output analysis, this divided by income multiplier and output multiplier. This results show that (1) Indonesian mining sectors ranked 6th with contribute amount of 6.81% on national total output; (2) Based on total gross value added, this sector contribute amount of 12.13% or ranked 4th; (3) The value from income multiplier is 0.7062 and the value from output multiplier is 1.2426.

  14. Hardware Implementation of a Bilateral Subtraction Filter

    Science.gov (United States)

    Huertas, Andres; Watson, Robert; Villalpando, Carlos; Goldberg, Steven

    2009-01-01

    its position in the window as well as the pixel value for the central pixel of the window. The absolute difference between these two pixel values is calculated and used as an address in a lookup table. Each processing element has a lookup table, unique for its position in the window, containing the weight coefficients for the Gaussian function for that position. The pixel value is multiplied by the weight, and the outputs of the processing element are the weight and pixel-value weight product. The products and weights are fed to the adder tree. The sum of the products and the sum of the weights are fed to the divider, which computes the sum of products the sum of weights. The output of the divider is denoted the bilateral smoothed image. The smoothing function is a simple weighted average computed over a 3 3 subwindow centered in the 9 9 window. After smoothing, the image is delayed by an additional amount of time needed to match the processing time for computing the bilateral smoothed image. The bilateral smoothed image is then subtracted from the 3 3 smoothed image to produce the final output. The prototype filter as implemented in a commercially available FPGA processes one pixel per clock cycle. Operation at a clock speed of 66 MHz has been demonstrated, and results of a static timing analysis have been interpreted as suggesting that the clock speed could be increased to as much as 100 MHz.

  15. Automatic dipole subtraction

    International Nuclear Information System (INIS)

    Hasegawa, K.

    2008-01-01

    The Catani-Seymour dipole subtraction is a general procedure to treat infrared divergences in real emission processes at next-to-leading order in QCD. We automatized the procedure in a computer code. The code is useful especially for the processes with many parton legs. In this talk, we first explain the algorithm of the dipole subtraction and the whole structure of our code. After that we show the results for some processes where the infrared divergences of real emission processes are subtracted. (author)

  16. Channel electron multipliers

    International Nuclear Information System (INIS)

    Seidman, A.; Avrahami, Z.; Sheinfux, B.; Grinberg, J.

    1976-01-01

    A channel electron multiplier is described having a tubular wall coated with a secondary-electron emitting material and including an electric field for accelerating the electrons, the electric field comprising a plurality of low-resistive conductive rings each alternating with a high-resistive insulating ring. The thickness of the low-resistive rings is many times larger than that of the high-resistive rings, being in the order of tens of microns for the low-resistive rings and at least one order of magnitude lower for the high-resistive rings; and the diameter of the channel tubular walls is also many times larger than the thickness of the high-resistive rings. Both single-channel and multiple-channel electron multipliers are described. A very important advantage, particularly in making multiple-channel multipliers, is the simplicity of the procedure that may be used in constructing such multipliers. Other operational advantages are described

  17. Building Maintenance. Math Learning Activity Packet.

    Science.gov (United States)

    Grant, Shelia I.

    This collection of learning activities is intended for use in reinforcing mathematics instruction as it relates to building maintenance. Fifty activity sheets are provided. These are organized into units on the following topics: numeration, adding whole numbers, subtracting whole numbers, multiplying whole numbers, dividing whole numbers,…

  18. 99mTc-RBC subtraction scintigraphy

    International Nuclear Information System (INIS)

    Inagaki, Syoichi; Tonami, Syuichi; Yasui, Masakazu; Kuranishi, Makoto; Sugishita, Kouki; Nakamura, Mamoru

    1994-01-01

    Sequential abdominal scintigrams with 99m Tc-labelled red blood cells (RBC) were subtracted for observing a site of gastrointestinal bleeding and calculating the bleeding rate. This method is technically very easy and can detect the site of bleeding with the minimum rate, as low as 0.2 ml/min., in a phantom experiment. In 23 cases with final diagnosis of gastrointestinal bleeding, conventional non-subtraction scintigraphy detected only 30% (7/23), but subtraction scintigraphy detected 61% (14/23). It was concluded that subtraction scintigraphy had higher sensitivity than conventional scintigraphy for early diagnosing bleeding. A combination of non-subtraction and subtraction scintigraphy is recommended to detect a site of gastrointestinal bleeding in a clinical setting. (author)

  19. Exercise intravenous digital subtraction angiography

    International Nuclear Information System (INIS)

    Yiannikas, J.

    1986-01-01

    Attempts to use exercise ventriculography have been made, not only to give diagnostic and perhaps even prognostic information in patients with coronary artery disease, but also in patients with valvular heart disease both before and after surgical intervention. Clearly an accurate method of assessing ventricular function under conditions of stress in various cardiac diseases would provide important information that would help in patient management. Exercise ventriculography using gated blood pool equilibrium technetium studies are widely used, but are limited by spatial resolution and by the foreshortening affects of visualizing the left ventricular chamber in the left anterior oblique view. First pass radionuclide studies have the added advantage of being able to visualize the ventricular chamber in the anterior or even the right anterior oblique view, but are even more limited by their spatial resolution problems. Several investigations have shown that digital subtraction angiography produces left ventricular images with a spatial resolution almost identical to that of conventional contrast ventriculography, but without the inherent problems of cardiac arrhythmias, which often limit the assessment of left ventricular function. Because of its ability to accurately delineate wall motion abnormalities, the technique may provide an adequate assessment of global and regional left ventricular function after exercise. Digital subtraction angiography may identify ischemic wall motion abnormalities produced by exercise in patients who already had significant permanent left ventricular damage from myocardial infarction

  20. Kodak Skills Enhancement Program Curriculum: Math for Manufacturing and Quality Control. Report No. AEP-93-01.

    Science.gov (United States)

    Beaudin, Bart P.; And Others

    This teacher's guide is intended for use in helping Kodak Corporation employees develop the basic mathematics skills required to perform the manufacturing and quality control tasks expected of them. The following topics are covered in the first five modules: the four basic functions (adding, subtracting, multiplying, and dividing), calculations…

  1. Helping Students with Emotional and Behavioral Disorders Solve Mathematics Word Problems

    Science.gov (United States)

    Alter, Peter

    2012-01-01

    The author presents a strategy for helping students with emotional and behavioral disorders become more proficient at solving math word problems. Math word problems require students to go beyond simple computation in mathematics (e.g., adding, subtracting, multiplying, and dividing) and use higher level reasoning that includes recognizing relevant…

  2. UWB delay and multiply receiver

    Energy Technology Data Exchange (ETDEWEB)

    Dallum, Gregory E.; Pratt, Garth C.; Haugen, Peter C.; Romero, Carlos E.

    2013-09-10

    An ultra-wideband (UWB) delay and multiply receiver is formed of a receive antenna; a variable gain attenuator connected to the receive antenna; a signal splitter connected to the variable gain attenuator; a multiplier having one input connected to an undelayed signal from the signal splitter and another input connected to a delayed signal from the signal splitter, the delay between the splitter signals being equal to the spacing between pulses from a transmitter whose pulses are being received by the receive antenna; a peak detection circuit connected to the output of the multiplier and connected to the variable gain attenuator to control the variable gain attenuator to maintain a constant amplitude output from the multiplier; and a digital output circuit connected to the output of the multiplier.

  3. Faster and Energy-Efficient Signed Multipliers

    Directory of Open Access Journals (Sweden)

    B. Ramkumar

    2013-01-01

    Full Text Available We demonstrate faster and energy-efficient column compression multiplication with very small area overheads by using a combination of two techniques: partition of the partial products into two parts for independent parallel column compression and acceleration of the final addition using new hybrid adder structures proposed here. Based on the proposed techniques, 8-b, 16-b, 32-b, and 64-b Wallace (W, Dadda (D, and HPM (H reduction tree based Baugh-Wooley multipliers are developed and compared with the regular W, D, H based Baugh-Wooley multipliers. The performances of the proposed multipliers are analyzed by evaluating the delay, area, and power, with 65 nm process technologies on interconnect and layout using industry standard design and layout tools. The result analysis shows that the 64-bit proposed multipliers are as much as 29%, 27%, and 21% faster than the regular W, D, H based Baugh-Wooley multipliers, respectively, with a maximum of only 2.4% power overhead. Also, the power-delay products (energy consumption of the proposed 16-b, 32-b, and 64-b multipliers are significantly lower than those of the regular Baugh-Wooley multiplier. Applicability of the proposed techniques to the Booth-Encoded multipliers is also discussed.

  4. X-ray image subtracting system

    International Nuclear Information System (INIS)

    Wesbey, W.H.; Keyes, G.S.; Georges, J.-P.J.

    1982-01-01

    An X-ray image subtracting system for making low contrast structures in the images more conspicuous is described. An X-ray source projects successive high and low energy X-ray beam pulses through a body and the resultant X-ray images are converted to optical images. Two image pick-up devices such as TV cameras that have synchronously operated shutters receive the alternate images and convert them to corresponding analog video signals. In some embodiments, the analog signals are converted to a matrix of digital pixel signals that are variously processed and subtracted and converted to signals for driving a TV monitor display and analog storage devices. In other embodiments the signals are processed and subtracted in analog form for display. The high and low energy pulses can follow each other immediately so good registration between subtracted images is obtainable even though the anatomy is in motion. The energy levels of the X-ray pulses are chosen to maximize the difference in attenuation between the anatomical structure which is to be subtracted out and that which remains. (author)

  5. Temporal subtraction of dual-energy chest radiographs

    International Nuclear Information System (INIS)

    Armato, Samuel G. III; Doshi, Devang J.; Engelmann, Roger; Caligiuri, Philip; MacMahon, Heber

    2006-01-01

    Temporal subtraction and dual-energy imaging are two enhanced radiography techniques that are receiving increased attention in chest radiography. Temporal subtraction is an image processing technique that facilitates the visualization of pathologic change across serial chest radiographic images acquired from the same patient; dual-energy imaging exploits the differential relative attenuation of x-ray photons exhibited by soft-tissue and bony structures at different x-ray energies to generate a pair of images that accentuate those structures. Although temporal subtraction images provide a powerful mechanism for enhancing visualization of subtle change, misregistration artifacts in these images can mimic or obscure abnormalities. The purpose of this study was to evaluate whether dual-energy imaging could improve the quality of temporal subtraction images. Temporal subtraction images were generated from 100 pairs of temporally sequential standard radiographic chest images and from the corresponding 100 pairs of dual-energy, soft-tissue radiographic images. The registration accuracy demonstrated in the resulting temporal subtraction images was evaluated subjectively by two radiologists. The registration accuracy of the soft-tissue-based temporal subtraction images was rated superior to that of the conventional temporal subtraction images. Registration accuracy also was evaluated objectively through an automated method, which achieved an area-under-the-ROC-curve value of 0.92 in the distinction between temporal subtraction images that demonstrated clinically acceptable and clinically unacceptable registration accuracy. By combining dual-energy soft-tissue images with temporal subtraction, misregistration artifacts can be reduced and superior image quality can be obtained

  6. Ceramic Electron Multiplier

    International Nuclear Information System (INIS)

    Comby, G.

    1996-01-01

    The Ceramic Electron Multipliers (CEM) is a compact, robust, linear and fast multi-channel electron multiplier. The Multi Layer Ceramic Technique (MLCT) allows to build metallic dynodes inside a compact ceramic block. The activation of the metallic dynodes enhances their secondary electron emission (SEE). The CEM can be used in multi-channel photomultipliers, multi-channel light intensifiers, ion detection, spectroscopy, analysis of time of flight events, particle detection or Cherenkov imaging detectors. (auth)

  7. Digital subtraction angiography of the heart and lungs

    International Nuclear Information System (INIS)

    Moodie, D.S.; Yiannikas, J.

    1986-01-01

    This book contains 12 chapters. Some of the chapter titles are: Physical Principles of Cardiac Digital Subtraction Angiography, The Use of Intravenous Digital Subtraction Angiography in Evaluating Patients with Complex Congenital Heart Disease, Exercise Intravenous Digital Subtraction Angiograpny, Cardiomyopathic and Cardiac Neoplastic Disease, Digital Subtraction Angiography in the Catheterization Laboratory, and Cardiac Digital Subtraction Angiography - Future Directions

  8. The value of subtraction MRI in detection of amyloid-related imaging abnormalities with oedema or effusion in Alzheimer's patients: An interobserver study.

    Science.gov (United States)

    Martens, Roland M; Bechten, Arianne; Ingala, Silvia; van Schijndel, Ronald A; Machado, Vania B; de Jong, Marcus C; Sanchez, Esther; Purcell, Derk; Arrighi, Michael H; Brashear, Robert H; Wattjes, Mike P; Barkhof, Frederik

    2018-03-01

    Immunotherapeutic treatments targeting amyloid-β plaques in Alzheimer's disease (AD) are associated with the presence of amyloid-related imaging abnormalities with oedema or effusion (ARIA-E), whose detection and classification is crucial to evaluate subjects enrolled in clinical trials. To investigate the applicability of subtraction MRI in the ARIA-E detection using an established ARIA-E-rating scale. We included 75 AD patients receiving bapineuzumab treatment, including 29 ARIA-E cases. Five neuroradiologists rated their brain MRI-scans with and without subtraction images. The accuracy of evaluating the presence of ARIA-E, intraclass correlation coefficient (ICC) and specific agreement was calculated. Subtraction resulted in higher sensitivity (0.966) and lower specificity (0.970) than native images (0.959, 0.991, respectively). Individual rater detection was excellent. ICC scores ranged from excellent to good, except for gyral swelling (moderate). Excellent negative and good positive specific agreement among all ARIA-E imaging features was reported in both groups. Combining sulcal hyperintensity and gyral swelling significantly increased positive agreement for subtraction images. Subtraction MRI has potential as a visual aid increasing the sensitivity of ARIA-E assessment. However, in order to improve its usefulness isotropic acquisition and enhanced training are required. The ARIA-E rating scale may benefit from combining sulcal hyperintensity and swelling. • Subtraction technique can improve detection amyloid-related imaging-abnormalities with edema/effusion in Alzheimer's patients. • The value of ARIA-E detection, classification and monitoring using subtraction was assessed. • Validation of an established ARIA-E rating scale, recommendations for improvement are reported. • Complementary statistical methods were employed to measure accuracy, inter-rater-reliability and specific agreement.

  9. Background subtraction theory and practice

    CERN Document Server

    Elgammal, Ahmed

    2014-01-01

    Background subtraction is a widely used concept for detection of moving objects in videos. In the last two decades there has been a lot of development in designing algorithms for background subtraction, as well as wide use of these algorithms in various important applications, such as visual surveillance, sports video analysis, motion capture, etc. Various statistical approaches have been proposed to model scene backgrounds. The concept of background subtraction also has been extended to detect objects from videos captured from moving cameras. This book reviews the concept and practice of back

  10. Recoded and nonrecoded trinary signed-digit adders and multipliers with redundant-bit representations

    Science.gov (United States)

    Cherri, Abdallah K.; Alam, Mohammed S.

    1998-07-01

    Highly-efficient two-step recoded and one-step nonrecoded trinary signed-digit (TSD) carry-free adders subtracters are presented on the basis of redundant-bit representation for the operands digits. It has been shown that only 24 (30) minterms are needed to implement the two-step recoded (the one-step nonrecoded) TSD addition for any operand length. Optical implementation of the proposed arithmetic can be carried out by use of correlation- or matrix-multiplication-based schemes, saving 50% of the system memory. Furthermore, we present four different multiplication designs based on our proposed recoded and nonrecoded TSD adders. Our multiplication designs require a small number of reduced minterms to generate the multiplication partial products. Finally, a recently proposed pipelined iterative-tree algorithm can be used in the TSD adders multipliers; consequently, efficient use of all available adders can be made.

  11. Synthesis algorithm of VLSI multipliers for ASIC

    Science.gov (United States)

    Chua, O. H.; Eldin, A. G.

    1993-01-01

    Multipliers are critical sub-blocks in ASIC design, especially for digital signal processing and communications applications. A flexible multiplier synthesis tool is developed which is capable of generating multiplier blocks for word size in the range of 4 to 256 bits. A comparison of existing multiplier algorithms is made in terms of speed, silicon area, and suitability for automated synthesis and verification of its VLSI implementation. The algorithm divides the range of supported word sizes into sub-ranges and provides each sub-range with a specific multiplier architecture for optimal speed and area. The algorithm of the synthesis tool and the multiplier architectures are presented. Circuit implementation and the automated synthesis methodology are discussed.

  12. A subtraction scheme for computing QCD jet cross sections at NNLO: integrating the subtraction terms I

    Science.gov (United States)

    Somogyi, Gábor; Trócsányi, Zoltán

    2008-08-01

    In previous articles we outlined a subtraction scheme for regularizing doubly-real emission and real-virtual emission in next-to-next-to-leading order (NNLO) calculations of jet cross sections in electron-positron annihilation. In order to find the NNLO correction these subtraction terms have to be integrated over the factorized unresolved phase space and combined with the two-loop corrections. In this paper we perform the integration of all one-parton unresolved subtraction terms.

  13. Tritium-caused background currents in electron multipliers

    International Nuclear Information System (INIS)

    Malinowski, M.E.

    1979-05-01

    One channel electron multiplier (Galileo No. 4501) and one 14 stage Be/Cu multiplier (Dumont No. SPM3) were exposed to tritium pressures between approx. 10 -7 Torr to 10 -3 Torr in amounts from approx. 10 -5 Torr-s to 60 Torr-s and the β-decay caused currents in the multipliers measured. The background currents in both multipliers consisted of two components: (1) a high, reversible current which was proportional to the tritium exposure pressure; and (2) a lower, irreversible background current which increased with increasing cumulative tritium exposure. The β-decay caused currents in each multiplier increased the same way with exposure, suggesting the detected electrons arose from decaying tritium adsorbed on surfaced external to the multipliers

  14. Bone images from dual-energy subtraction chest radiography in the detection of rib fractures

    Energy Technology Data Exchange (ETDEWEB)

    Szucs-Farkas, Zsolt, E-mail: zsolt.szuecs@insel.ch [Department of Diagnostic, Interventional and Pediatric Radiology, University Hospital Bern, Freiburgstrasse 4, Bern CH-3010 (Switzerland); Lautenschlager, Katrin, E-mail: katrin@students.unibe.ch [Department of Diagnostic, Interventional and Pediatric Radiology, University Hospital Bern, Freiburgstrasse 4, Bern CH-3010 (Switzerland); Flach, Patricia M., E-mail: patricia.flach@irm.unibe.ch [Institute of Forensic Medicine, University of Bern, Freiburgstrasse 4, Bern CH-3010 (Switzerland); Ott, Daniel, E-mail: daniel.ott@insel.ch [Department of Diagnostic, Interventional and Pediatric Radiology, University Hospital Bern, Freiburgstrasse 4, Bern CH-3010 (Switzerland); Strautz, Tamara, E-mail: tamara.strautz@insel.ch [Department of Diagnostic, Interventional and Pediatric Radiology, University Hospital Bern, Freiburgstrasse 4, Bern CH-3010 (Switzerland); Vock, Peter, E-mail: peter.vock@insel.ch [Department of Diagnostic, Interventional and Pediatric Radiology, University Hospital Bern, Freiburgstrasse 4, Bern CH-3010 (Switzerland); Ruder, Thomas D., E-mail: thomas.ruder@irm.unibe.ch [Institute of Forensic Medicine, University of Bern, Freiburgstrasse 4, Bern CH-3010 (Switzerland)

    2011-08-15

    Objective: To assess the sensitivity and image quality of chest radiography (CXR) with or without dual-energy subtracted (ES) bone images in the detection of rib fractures. Materials and methods: In this retrospective study, 39 patients with 204 rib fractures and 24 subjects with no fractures were examined with a single exposure dual-energy subtraction digital radiography system. Three blinded readers first evaluated the non-subtracted posteroanterior and lateral chest radiographs alone, and 3 months later they evaluated the non-subtracted images together with the subtracted posteroanterior bone images. The locations of rib fractures were registered with confidence levels on a 3-grade scale. Image quality was rated on a 5-point scale. Marks by readers were compared with fracture localizations in CT as a standard of reference. Results: The sensivity for fracture detection using both methods was very similar (34.3% with standard CXR and 33.5% with ES-CXR, p = 0.92). At the patient level, both sensitivity (71.8%) and specificity (92.9%) with or without ES were identical. Diagnostic confidence was not significantly different (2.61 with CXR and 2.75 with ES-CXR, p = 0.063). Image quality with ES was rated higher than that on standard CXR (4.08 vs. 3.74, p < 0.001). Conclusions: Despite a better image quality, adding ES bone images to standard radiographs of the chest does not provide better sensitivity or improved diagnostic confidence in the detection of rib fractures.

  15. The value of subtraction MRI in detection of amyloid-related imaging abnormalities with oedema or effusion in Alzheimer's patients. An interobserver study

    International Nuclear Information System (INIS)

    Martens, Roland M.; Bechten, Arianne; Ingala, Silvia; Schijndel, Ronald A. van; Machado, Vania B.; Jong, Marcus C. de; Sanchez, Esther; Wattjes, Mike P.; Purcell, Derk; Arrighi, Michael H.; Brashear, Robert H.; Barkhof, Frederik

    2018-01-01

    Immunotherapeutic treatments targeting amyloid-β plaques in Alzheimer's disease (AD) are associated with the presence of amyloid-related imaging abnormalities with oedema or effusion (ARIA-E), whose detection and classification is crucial to evaluate subjects enrolled in clinical trials. To investigate the applicability of subtraction MRI in the ARIA-E detection using an established ARIA-E-rating scale. We included 75 AD patients receiving bapineuzumab treatment, including 29 ARIA-E cases. Five neuroradiologists rated their brain MRI-scans with and without subtraction images. The accuracy of evaluating the presence of ARIA-E, intraclass correlation coefficient (ICC) and specific agreement was calculated. Subtraction resulted in higher sensitivity (0.966) and lower specificity (0.970) than native images (0.959, 0.991, respectively). Individual rater detection was excellent. ICC scores ranged from excellent to good, except for gyral swelling (moderate). Excellent negative and good positive specific agreement among all ARIA-E imaging features was reported in both groups. Combining sulcal hyperintensity and gyral swelling significantly increased positive agreement for subtraction images. Subtraction MRI has potential as a visual aid increasing the sensitivity of ARIA-E assessment. However, in order to improve its usefulness isotropic acquisition and enhanced training are required. The ARIA-E rating scale may benefit from combining sulcal hyperintensity and swelling. (orig.)

  16. The value of subtraction MRI in detection of amyloid-related imaging abnormalities with oedema or effusion in Alzheimer's patients. An interobserver study

    Energy Technology Data Exchange (ETDEWEB)

    Martens, Roland M.; Bechten, Arianne; Ingala, Silvia; Schijndel, Ronald A. van; Machado, Vania B.; Jong, Marcus C. de; Sanchez, Esther; Wattjes, Mike P. [VU University Medical Center, Department of Radiology and Nuclear Medicine, Neuroscience Campus Amsterdam (Netherlands); Purcell, Derk [California Pacific Medical Center, Department of Radiology, San Francisco, CA (United States); BioClinica Inc, Newark, CA (United States); Arrighi, Michael H.; Brashear, Robert H. [Janssen Alzheimer Immunotherapy Research and Development, LLC, South San Francisco, CA (United States); Barkhof, Frederik [VU University Medical Center, Department of Radiology and Nuclear Medicine, Neuroscience Campus Amsterdam (Netherlands); University College London, Institutes of Neurology and Healthcare Engineering, London (United Kingdom)

    2018-03-15

    Immunotherapeutic treatments targeting amyloid-β plaques in Alzheimer's disease (AD) are associated with the presence of amyloid-related imaging abnormalities with oedema or effusion (ARIA-E), whose detection and classification is crucial to evaluate subjects enrolled in clinical trials. To investigate the applicability of subtraction MRI in the ARIA-E detection using an established ARIA-E-rating scale. We included 75 AD patients receiving bapineuzumab treatment, including 29 ARIA-E cases. Five neuroradiologists rated their brain MRI-scans with and without subtraction images. The accuracy of evaluating the presence of ARIA-E, intraclass correlation coefficient (ICC) and specific agreement was calculated. Subtraction resulted in higher sensitivity (0.966) and lower specificity (0.970) than native images (0.959, 0.991, respectively). Individual rater detection was excellent. ICC scores ranged from excellent to good, except for gyral swelling (moderate). Excellent negative and good positive specific agreement among all ARIA-E imaging features was reported in both groups. Combining sulcal hyperintensity and gyral swelling significantly increased positive agreement for subtraction images. Subtraction MRI has potential as a visual aid increasing the sensitivity of ARIA-E assessment. However, in order to improve its usefulness isotropic acquisition and enhanced training are required. The ARIA-E rating scale may benefit from combining sulcal hyperintensity and swelling. (orig.)

  17. Estimation's Role in Calculations with Fractions

    Science.gov (United States)

    Johanning, Debra I.

    2011-01-01

    Estimation is more than a skill or an isolated topic. It is a thinking tool that needs to be emphasized during instruction so that students will learn to develop algorithmic procedures and meaning for fraction operations. For students to realize when fractions should be added, subtracted, multiplied, or divided, they need to develop a sense of…

  18. Digital contrast subtraction radiography for proximal caries diagnosis

    International Nuclear Information System (INIS)

    Kang, Byung Cheol; Yoon, Suk Ja

    2002-01-01

    To determine whether subtraction images utilizing contrast media can improve the diagnostic performance of proximal caries diagnosis compared to conventional periapical radiographic images. Thirty-six teeth with 57 proximal surfaces were radiographied using a size no.2 RVG-ui sensor (Trophy Radiology, Marne-la-Vallee, France). The teeth immersed in water-soluble contrast media and subtraction images were taken. Each tooth was then sectioned for histologic examination. The digital radiographic images and subtraction images were examined and interpreted by three dentists for proximal caries. The results of the proximal caries diagnosis were then verified with the results of the histologic examination. The proximal caries sensitivity using digital subtraction radiography was significantly higher than simply examining a single digital radiograph. The sensitivity of the proximal dentinal carious lesion when analyzed with the subtraction radiograph and the radiograph together was higher than with the subtraction radiograph or the radiograph alone. The use of subtraction radiography with contrast media may be useful for detecting proximal dentinal carious lesions.

  19. Digital subtraction angiography for breast cancer

    International Nuclear Information System (INIS)

    Tsurumi, Kiyohiko; Okuyama, Nobuo

    1987-01-01

    We performed digital subtraction angiography (DSA) on 42 patients with breast diseases to investigate its efficiency. As a result we came to the following conclusions: 1. The sensitivity was well evaluated in intraarterial digital subtraction angiography (IA-DSA) of breast. 2. IA-DSA could diagnose difficult cases like cancer which had undergone augmentation mammoplasty, or like Paget's disease and others. 3. DSA was a safe examination method. 4. The sensitivity of IA-DSA of breast cancer is superior to intravenous digital subtraction angiography (IV-DSA). (author)

  20. Digital subtraction angiography in ischemic cerebrovascular accidents

    Energy Technology Data Exchange (ETDEWEB)

    Manelfe, C.; Bonafe, A.; Ducos de Lahitte, M.; Rascol, A.; Prere, J.; Guiraud, B.; Marc-Vergnes, J.P. (Hopital Purpan, 31 - Toulouse (France))

    1983-12-29

    Recent advances in computer and radiological technology have permitted reassessment of intravenous angiography in the evaluation of cerebrovascular disorders. Although digital subtraction angiography is a relatively new technique, it has rapidly gained a widespread acceptance. It has extended the use of angiography to outpatients and to people in whom conventional angiography is contraindicated. This reliable, safe, and relatively noninvasive technique offers the user two benefits: real-time subtraction and enhanced image quality. The system allows angiographic evaluation of the extracranial and intracranial vessels by means of intravenous injection of contrast material. Extracranial studies clearly demonstrate stenoses and occlusions of the major cervicocephalic arteries. Intracranial studies usually detect major cerebrovascular occlusions and provide insight into the collateral flow patterns. Intravenous digital subtraction angiography permits accurate assessment of cervicocephalic vessels after surgical repair. Although intravenous digital subtraction angiography obviates the need for conventional angiography in many cases, movements from the patients, or superimposition of vascular structures can substantially degrade the quality of the images. Digital subtraction angiography with intra-arterial injection of contrast medium will be contemplated in patients with poor intravenous digital subtraction angiography studies prior to surgery.

  1. Digital subtraction angiography in ischemic cerebrovascular accidents

    International Nuclear Information System (INIS)

    Manelfe, C.; Bonafe, A.; Ducos de Lahitte, M.; Rascol, A.; Prere, J.; Guiraud, B.; Marc-Vergnes, J.P.

    1983-01-01

    Recent advances in computer and radiological technology have permitted reassessment of intravenous angiography in the evaluation of cerebrovascular disorders. Although digital subtraction angiography is a relatively new technique, it has rapidly gained a widespread acceptance. It has extended the use of angiography to outpatients and to people in whom conventional angiography is contraindicated. This reliable, safe, and relatively noninvasive technique offers the user two benefits: real-time subtraction and enhanced image quality. The system allows angiographic evaluation of the extracranial and intracranial vessels by means of intravenous injection of contrast material. Extracranial studies clearly demonstrate stenoses and occlusions of the major cervicocephalic arteries. Intracranial studies usually detect major cerebrovascular occlusions and provide insight into the collateral flow patterns. Intravenous digital subtraction angiography permits accurate assessment of cervicocephalic vessels after surgical repair. Although intravenous digital subtraction angiography obviates the need for conventional angiography in many cases, movements from the patients, or superimposition of vascular structures can substantially degrade the quality of the images. Digital subtraction angiography with intra-arterial injection of contrast medium will be contemplated in patients with poor intravenous digital subtraction angiography studies prior to surgery [fr

  2. Calculated characteristics of multichannel photoelectron multipliers

    International Nuclear Information System (INIS)

    Vasil'chenko, V.G.; Dajkovskij, A.G.; Milova, N.V.; Rakhmatov, V.E.; Rykalin, V.I.

    1990-01-01

    Structural features and main calculated characteristics of some modifications of position-sensitive two-coordinate multichannel photoelectron multipliers (PEM) with plate-type multiplying systems are described. The presented PEM structures are free from direct optical and ion feedbacks, provide coordinate resolution ≅ 1 mm with efficiency of photoelectron detection ≅ 90%. Capabilities for using silicon field-effect photocathodes, providing electron extraction into vacuum, as well as prospects of using multichannel multiplying systems for readout of the data from solid detectors are considered

  3. Medicaid Contradictions: Adding, Subtracting, and Redeterminations in Illinois.

    Science.gov (United States)

    Koetting, Michael

    2016-04-01

    States are required to conduct annual Medicaid redeterminations. How these redeterminations are undertaken is crucial to determining the nature of Medicaid coverage. There can be wide variations in the proportion of clients disenrolled, with potentially large numbers of people disenrolled each year. This case study of Illinois Medicaid shows how, as the Affordable Care Act added people, redeterminations were taking people off the rolls-about 25 percent of all Medicaid clients were disenrolled in one year. Many of these people were no longer eligible, but it appears that a larger number were in fact eligible but simply failed to comply with administrative requirements in a timely way. Balancing between the two imperatives of program integrity and continuity of care is a difficult act for Medicaid programs. The Illinois experience also illustrates impacts on information technology and outsourcing of eligibility functions, not to mention budget considerations. Copyright © 2016 by Duke University Press.

  4. Study of Confinement/Deconfinement Transition in AdS/QCD with Generalized Warp Factors

    Directory of Open Access Journals (Sweden)

    Shobhit Sachan

    2014-01-01

    Full Text Available We study analytical solutions of charged black holes and thermally charged AdS with generalized warped factors in Einstein-Maxwell-Dilaton system. We calculate Euclidean action for charged AdS and thermally charged AdS. The actions in both backgrounds are regularized by the method of background subtraction. The study of phase transition between charged black hole and thermally charged AdS gives an insight into the confinement/deconfinement transition. The plots of grand potential versus temperature and chemical potential versus transition temperature are obtained.

  5. Utility of noise addition image made by using water phantom and image addition and subtraction software

    International Nuclear Information System (INIS)

    Watanabe, Ryo; Aoki, Takahiro; Hayano, Mizuho; Ogawa, Masato; Mituzono, Hiroki; Watanabe, Yuka

    2010-01-01

    In optimizing exposures, it is very important to evaluate the impact of image noise on image quality. To realize this, there is a need to evaluate how much image noise will make the subject disease invisible. But generally it is very difficult to shoot images of different quality in a clinical examination. Thus, a method to create a noise addition image by adding the image noise to raw data has been reported. However, this approach requires a special system, so it is difficult to implement in many facilities. We have invented a method to easily create a noise addition image by using the water phantom and image add-subtract software that accompanies the device. To create a noise addition image, first we made a noise image by subtracting the water phantom with different standard deviation (SD). A noise addition image was then created by adding the noise image to the original image. By using this method, a simulation image with intergraded SD can be created from the original. Moreover, the noise frequency component of the created noise addition image is as same as the real image. Thus, the relationship of image quality to SD in the clinical image can be evaluated. Although this method is an easy method of LDSI creation on image data, a noise addition image can be easily created by using image addition and subtraction software and water phantom, and this can be implemented in many facilities. (author)

  6. BPHZL-subtraction scheme and axial gauges

    Energy Technology Data Exchange (ETDEWEB)

    Kreuzer, M.; Rebhan, A.; Schweda, M.; Piguet, O.

    1986-03-27

    The application of the BPHZL subtraction scheme to Yang-Mills theories in axial gauges is presented. In the auxillary mass formulation we show the validity of the convergence theorems for subtracted momentum space integrals, and we give the integral formulae necessary for one-loop calculations. (orig.).

  7. Design of two easily-testable VLSI array multipliers

    Energy Technology Data Exchange (ETDEWEB)

    Ferguson, J.; Shen, J.P.

    1983-01-01

    Array multipliers are well-suited to VLSI implementation because of the regularity in their iterative structure. However, most VLSI circuits are very difficult to test. This paper shows that, with appropriate cell design, array multipliers can be designed to be very easily testable. An array multiplier is called c-testable if all its adder cells can be exhaustively tested while requiring only a constant number of test patterns. The testability of two well-known array multiplier structures are studied. The conventional design of the carry-save array multipler is shown to be not c-testable. However, a modified design, using a modified adder cell, is generated and shown to be c-testable and requires only 16 test patterns. Similar results are obtained for the baugh-wooley two's complement array multiplier. A modified design of the baugh-wooley array multiplier is shown to be c-testable and requires 55 test patterns. The implementation of a practical c-testable 16*16 array multiplier is also presented. 10 references.

  8. Subtracted versus non-subtracted digital imaging in peripheral angiography

    International Nuclear Information System (INIS)

    Fink, U.; Heywang, S.; Mayr, B.; Berger, H.

    1989-01-01

    Digital subtraction angiography (DSA) plays an important role in the management of vascular diseases of the lower extremities. A disadvantage is the lack of an automatically moving table top. We used a 1,024x1,024 matrix with a large-screen intensifier system and an automated 'stepping' facility. In 161 examinations of the arteries of the lower extremity digital peripheral arteriography was performed with and without the subtraction technique. We compared the influence of different iodine concentrations in DA and DSA. Peripheral DA proved to be equal to peripheral DSA in the region of the pelvis, thigh and knee, with no adequate contrasting being obtained merely in the region of the lower leg arteries in about 45%. It is necessary to use contrast medium at a concentration of 300 mg I/ml. The installation of an automated 'stepping' facility reduces the amount of contrast' medium needed and the exposure time. (orig.)

  9. Comparison between various notions of conserved charges in asymptotically AdS spacetimes

    International Nuclear Information System (INIS)

    Hollands, Stefan; Ishibashi, Akihiro; Marolf, Donald

    2005-01-01

    We derive Hamiltonian generators of asymptotic symmetries for general relativity with asymptotic AdS boundary conditions using the 'covariant phase space' method of Wald et al. We then compare our results with other definitions that have been proposed in the literature. We find that our definition agrees with that proposed by Ashtekar et al, with the spinor definition, and with the background-dependent definition of Henneaux and Teitelboim. Our definition disagrees with that obtained from the 'counterterm subtraction method', but the difference is found to consist only of a 'constant offset' that is determined entirely in terms of the boundary metric. We finally discuss and justify our boundary conditions by a linear perturbation analysis, and we comment on generalizations of our boundary conditions, as well as inclusion of matter fields

  10. Faster Double-Size Bipartite Multiplication out of Montgomery Multipliers

    Science.gov (United States)

    Yoshino, Masayuki; Okeya, Katsuyuki; Vuillaume, Camille

    This paper proposes novel algorithms for computing double-size modular multiplications with few modulus-dependent precomputations. Low-end devices such as smartcards are usually equipped with hardware Montgomery multipliers. However, due to progresses of mathematical attacks, security institutions such as NIST have steadily demanded longer bit-lengths for public-key cryptography, making the multipliers quickly obsolete. In an attempt to extend the lifespan of such multipliers, double-size techniques compute modular multiplications with twice the bit-length of the multipliers. Techniques are known for extending the bit-length of classical Euclidean multipliers, of Montgomery multipliers and the combination thereof, namely bipartite multipliers. However, unlike classical and bipartite multiplications, Montgomery multiplications involve modulus-dependent precomputations, which amount to a large part of an RSA encryption or signature verification. The proposed double-size technique simulates double-size multiplications based on single-size Montgomery multipliers, and yet precomputations are essentially free: in an 2048-bit RSA encryption or signature verification with public exponent e=216+1, the proposal with a 1024-bit Montgomery multiplier is at least 1.5 times faster than previous double-size Montgomery multiplications.

  11. Self-masking subtraction tomosynthesis

    International Nuclear Information System (INIS)

    Chakraborty, D.P.; Yester, M.V.; Barnes, G.T.; Lakshminarayanan, A.V.

    1984-01-01

    The authors tested the image quality and dose savings of self-masking subtraction tomosynthesis (SST), which combines digital tomosynthesis with subtraction of a blurred self-mask. High-quality images of the inner ear of a head phantom were obtained at moderate dose savings. Although they were taken with linear motion, they did not exhibit the streaking due to off-fulcrum objects that is characteristic of conventional linear tomography. SST could reduce patient dose by a factor of at least 12 in examinations of the inner ear, and the mechanical aspects can be implemented with moderate modifications of existing instrumentation

  12. Left-right subtraction of brain CT

    International Nuclear Information System (INIS)

    Ishiguchi, Tsuneo; Sakuma, Sadayuki

    1986-01-01

    A new image-processing method to obtain a left-right subtraction image of CT was designed for the automated detection of abnormalities in brain CT. An original CT image was divided in two by a centerline. Then the right half of the image was subtracted from the left half by calculating the absorption value of the pixels on the symmetrical positions against the centerline. The mean and the standard deviation of the absorption value of the pixels in the subtraction image were used as parameters for analysis, and the detectability of abnormal CT findings was evaluated in 100 cases - 50 cases each with normal and abnormal CT. The presence of abnormalities could be diagnosed with a sensitivity of 86 %, a specificity of 90 %, and an overall accuracy of 88 % when the borderline of these parameters between normal and abnormal CT was set at the mean + 2SD in the normal group. As a further analysis, the CT image was subdivided into several areas from a functional or anatomical viewpoint, such as cerebral vascular territories, and the left-right subtraction image of each area was obtained. The possibilities of diagnosing the location of an abnormality and of detecting smaller lesions with this method were shown. Left-right subtraction was considered to be a useful method for the detection of asymmetric abnormalities in the automated diagnosis of brain CT. (author)

  13. Longitudinal development of subtraction performance in elementary school.

    Science.gov (United States)

    Artemenko, Christina; Pixner, Silvia; Moeller, Korbinian; Nuerk, Hans-Christoph

    2017-10-05

    A major goal of education in elementary mathematics is the mastery of arithmetic operations. However, research on subtraction is rather scarce, probably because subtraction is often implicitly assumed to be cognitively similar to addition, its mathematical inverse. To evaluate this assumption, we examined the relation between the borrow effect in subtraction and the carry effect in addition, and the developmental trajectory of the borrow effect in children using a choice reaction paradigm in a longitudinal study. In contrast to the carry effect in adults, carry and borrow effects in children were found to be categorical rather than continuous. From grades 3 to 4, children became more proficient in two-digit subtraction in general, but not in performing the borrow operation in particular. Thus, we observed no specific developmental progress in place-value computation, but a general improvement in subtraction procedures. Statement of contribution What is already known on this subject? The borrow operation increases difficulty in two-digit subtraction in adults. The carry effect in addition, as the inverse operation of borrowing, comprises categorical and continuous processing characteristics. What does this study add? In contrast to the carry effect in adults, the borrow and carry effects are categorical in elementary school children. Children generally improve in subtraction performance from grades 3 to 4 but do not progress in place-value computation in particular. © 2017 The British Psychological Society.

  14. Development of Shimadzu digital subtraction system

    International Nuclear Information System (INIS)

    Nishioka, Hiroyuki; Shibata, Koichi; Shimizu, Yasumitsu; Shibata, Kenji; Wani, Hidenobu

    1985-01-01

    Shimadzu has recently developed a digital subtraction system. It can perform intra-arterial digital subtraction angiography (DSA) using low concentration of contrast medium, or can visualize arteries with intravenuous injection. It can extremely reduce patient's pain in angiography. Image quality of DSA has been much improved by the development of high quality image amplifiers, improvement of signal-to-noise ratio of the x-ray television unit and the development of digital disk recorders. The peak-hold subtraction method that is now under clinical study presents images of blood vessels as the trace of the flow of contrast medium. The maximum-hold memory where the maximum value of the brightness in some period is stored for every picture element is subtracted from the minimum-hold memory where the minimum value is stored, and thus images of blood vessels can be obtained. Hardware of this method is rather simple and it is expected that the amount of contrast medium may be reduced or x-ray dose of the patient may be decreased. (author)

  15. Effective switching frequency multiplier inverter

    Science.gov (United States)

    Su, Gui-Jia [Oak Ridge, TN; Peng, Fang Z [Okemos, MI

    2007-08-07

    A switching frequency multiplier inverter for low inductance machines that uses parallel connection of switches and each switch is independently controlled according to a pulse width modulation scheme. The effective switching frequency is multiplied by the number of switches connected in parallel while each individual switch operates within its limit of switching frequency. This technique can also be used for other power converters such as DC/DC, AC/DC converters.

  16. An automated subtraction of NLO EW infrared divergences

    Energy Technology Data Exchange (ETDEWEB)

    Schoenherr, Marek [CERN, Theoretical Physics Department, Geneva (Switzerland)

    2018-02-15

    In this paper a generalisation of the Catani-Seymour dipole subtraction method to next-to-leading order electroweak calculations is presented. All singularities due to photon and gluon radiation off both massless and massive partons in the presence of both massless and massive spectators are accounted for. Particular attention is paid to the simultaneous subtraction of singularities of both QCD and electroweak origin which are present in the next-to-leading order corrections to processes with more than one perturbative order contributing at Born level. Similarly, embedding non-dipole-like photon splittings in the dipole subtraction scheme discussed. The implementation of the formulated subtraction scheme in the framework of the Sherpa Monte-Carlo event generator, including the restriction of the dipole phase space through the α-parameters and expanding its existing subtraction for NLO QCD calculations, is detailed and numerous internal consistency checks validating the obtained results are presented. (orig.)

  17. Soft-collinear factorization and zero-bin subtractions

    International Nuclear Information System (INIS)

    Chiu Juiyu; Fuhrer, Andreas; Kelley, Randall; Manohar, Aneesh V.; Hoang, Andre H.

    2009-01-01

    We study the Sudakov form factor for a spontaneously broken gauge theory using a (new) Δ-regulator. To be well defined, the effective theory requires zero-bin subtractions for the collinear sectors. The zero-bin subtractions depend on the gauge boson mass M and are not scaleless. They have both finite and 1/ε contributions and are needed to give the correct anomalous dimension and low-scale matching contributions. We also demonstrate the necessity of zero-bin subtractions for soft-collinear factorization. We find that after zero-bin subtractions the form factor is the sum of the collinear contributions minus a soft mass-mode contribution, in agreement with a previous result of Idilbi and Mehen in QCD. This appears to conflict with the method-of-regions approach, where one gets the sum of contributions from different regions.

  18. Multipliers for continuous frames in Hilbert spaces

    International Nuclear Information System (INIS)

    Balazs, P; Bayer, D; Rahimi, A

    2012-01-01

    In this paper, we examine the general theory of continuous frame multipliers in Hilbert space. These operators are a generalization of the widely used notion of (discrete) frame multipliers. Well-known examples include anti-Wick operators, STFT multipliers or Calderón–Toeplitz operators. Due to the possible peculiarities of the underlying measure spaces, continuous frames do not behave quite as their discrete counterparts. Nonetheless, many results similar to the discrete case are proven for continuous frame multipliers as well, for instance compactness and Schatten-class properties. Furthermore, the concepts of controlled and weighted frames are transferred to the continuous setting. This article is part of a special issue of Journal of Physics A: Mathematical and Theoretical devoted to ‘Coherent states: mathematical and physical aspects’. (paper)

  19. Lagrange multipliers and gravitational theory

    International Nuclear Information System (INIS)

    Elston, F.D.

    1977-01-01

    The Lagrange multiplier variational method is extended to nonlinear Lagrangians in a Riemann space, where it is shown explicitly for the quadratic Lagrangians that, as expected, this approach is equivalent to the Hilbert variational method. It is not, in general, equivalent to the Palatini variational method. The nonvanishing Lagrange multipliers for the quadratic Lagrangians are explicitly obtained in covariant form. A similiar analysis is then carried out in a Riemann--Cartan torsional metric space for the specific Lagrangians g/sup 1/2/R tilde and g/sup 1/2/R/sub uv/tilde R/sup uv/tilde. The possible relevance of the R/sub uv/R/sup u anti v/ invariant to an action-principle formulation of the Rainich--Misner--Wheeler (RMW) already-unified theory is also discussed. It is then pointed out how a different use of the Lagrange multiplier technique in the language of the 3 + 1 canonical formalism developed by Arnowitt, Deser, and Misner (ADM) permits the recasting of the equations of motion for quadratic and general higher-order invariants into the ADM canonical formalism. In general, without this Lagrange multiplier approach, the higher-order ADM problem could not be solved. This is done explicitly for the simplest quadratic Langrangian g/sup 1/2/R 2 as an example

  20. Keynesian multiplier versus velocity of money

    Science.gov (United States)

    Wang, Yougui; Xu, Yan; Liu, Li

    2010-08-01

    In this paper we present the relation between Keynesian multiplier and the velocity of money circulation in a money exchange model. For this purpose we modify the original exchange model by constructing the interrelation between income and expenditure. The random exchange yields an agent's income, which along with the amount of money he processed determines his expenditure. In this interactive process, both the circulation of money and Keynesian multiplier effect can be formulated. The equilibrium values of Keynesian multiplier are demonstrated to be closely related to the velocity of money. Thus the impacts of macroeconomic policies on aggregate income can be understood by concentrating solely on the variations of money circulation.

  1. Study of heterogeneous multiplying and non-multiplying media by the neutron pulsed source technique

    International Nuclear Information System (INIS)

    Deniz, V.

    1969-01-01

    The pulsed neutron technique consists essentially in sending in the medium to be studied a short neutron pulse and in determining the asymptotic decay constant of the generated population. The variation of the decay constant as a function of the size of the medium allows the medium characteristics to be defined. This technique has been largely developed these last years and has been applied as well to moderator as to multiplying media, in most cases homogeneous ones. We considered of interest of apply this technique to lattices, to see if useful informations could be collected for lattice calculations. We present here a general theoretical study of the problem, and results and interpretation of a series of experiments made on graphite lattices. There is a good agreement for non-multiplying media. In the case of multiplying media, it is shown that the age value used until now in graphite lattices calculations is over-estimated by about 10 per cent [fr

  2. On compact multipliers of topological algebras

    International Nuclear Information System (INIS)

    Mohammad, N.

    1994-08-01

    It is shown that if the maximal ideal space Δ(A) of a semisimple commutative complete metrizable locally convex algebra contains no isolated points, then every compact multiplier is trivial. Particularly, compact multipliers on semisimple commutative Frechet algebras whose maximal ideal space has no isolated points are identically zero. (author). 5 refs

  3. Subtraction and dynamic MR images of breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Murakami, Yoshitaka; Aoki, Manabu; Harada, Junta (Jikei Univ., Tokyo (Japan). School of Medicine)

    1993-04-01

    The purpose of this study was to evaluate the diagnostic effectiveness of subtraction and dynamic MR imaging in patients with breast masses. In 23 breast cancers and six fibroadenomas, spin echo T1 images were obtained at 0.2 Tesla before and every minute after intravenous injection of Gd-DTPA (0.1 or 0.2 mmol/kg). Subtraction images were obtained sequentially on the CRT monitor. All breast masses were enhanced after gadolinium and stood out as bright lesions on subtraction images. The tumor margin and its extension were more precisely evaluated on subtraction MR images than on conventional postcontrast MR images. Breast cancer showed a characteristic time-intensity curve with an early peak, in contrast to fibroadenoma, which showed a gradual increase in signal intensity. Subtraction MR imaging is a simple method for the evaluation of breast masses, and further, the time-intensity curve obtained by dynamic study is helpful in the differential diagnosis of lesions. (author).

  4. Spectral amplitude coding OCDMA using and subtraction technique.

    Science.gov (United States)

    Hasoon, Feras N; Aljunid, S A; Samad, M D A; Abdullah, Mohamad Khazani; Shaari, Sahbudin

    2008-03-20

    An optical decoding technique is proposed for a spectral-amplitude-coding-optical code division multiple access, namely, the AND subtraction technique. The theory is being elaborated and experimental results have been done by comparing a double-weight code against the existing code, Hadamard. We have proved that the and subtraction technique gives better bit error rate performance than the conventional complementary subtraction technique against the received power level.

  5. Optical studies of multiply excited states

    International Nuclear Information System (INIS)

    Mannervik, S.

    1989-01-01

    Optical studies of multiply-excited states are reviewed with emphasis on emission spectroscopy. From optical measurements, properties such as excitation energies, lifetimes and autoionization widths can be determined with high accuracy, which constitutes a challenge for modern computational methods. This article mainly covers work on two-, three- and four-electron systems, but also sodium-like quartet systems. Furthermore, some comments are given on bound multiply-excited states in negative ions. Fine structure effects on transition wavelengths and lifetimes (autoionization) are discussed. In particular, the most recent experimental and theoretical studies of multiply-excited states are covered. Some remaining problems, which require further attention, are discussed in more detail. (orig.) With 228 refs

  6. Otanps synapse linear relation multiplier circuit

    International Nuclear Information System (INIS)

    Chible, H.

    2008-01-01

    In this paper, a four quadrant VLSI analog multiplier will be proposed, in order to be used in the implementation of the neurons and synapses modules of the artificial neural networks. The main characteristics of this multiplier are the small silicon area and the low power consumption and the high value of the weight input voltage. (author)

  7. Parallel decompositions of Mueller matrices and polarimetric subtraction

    Directory of Open Access Journals (Sweden)

    Gil J.J.

    2010-06-01

    Full Text Available From a general formulation of the physically realizable parallel decompositions of the Mueller matrix M of a given depolarizing system, a procedure for determining the set of pure Mueller matrices susceptible to be subtracted from M is presented. This procedure provides a way to check if a given pure Mueller matrix N can be subtracted from M or not. If this check is positive, the value of the relative cross section of the subtracted component is also determined.

  8. The Multiplier Effect.

    Science.gov (United States)

    Flowers, William L., Jr.; Harris, John B.

    1981-01-01

    The multiplier effect is discussed as it applies to the field of continuing education. The authors' main point is that one grant or contract can, and should, be used as the basis for building organizational competencies and capabilities that will secure other funds. (Author/CT)

  9. Developing a Model to Support Students in Solving Subtraction

    Directory of Open Access Journals (Sweden)

    Nila Mareta Murdiyani

    2013-01-01

    Full Text Available Subtraction has two meanings and each meaning leads to the different strategies. The meaning of “taking away something” suggests a direct subtraction, while the meaning of “determining the difference between two numbers” is more likely to be modeled as indirect addition. Many prior researches found that the second meaning and second strategy rarely appeared in the mathematical textbooks and teacher explanations, including in Indonesia. Therefore, this study was conducted to contribute to the development of a local instruction theory for subtraction by designing instructional activities that can facilitate first grade of primary school students to develop a model in solving two digit numbers subtraction. Consequently, design research was chosen as an appropriate approach for achieving the research aim and Realistic Mathematics Education (RME was used as a guide to design the lesson. This study involved 6 students in the pilot experiment, 31 students in the teaching experiment, and a first grade teacher of SDN 179 Palembang. The  result of this study shows that the beads string could bridge students from the contextual problems (taking ginger candies and making grains bracelets to the use of the empty number line. It also shows that the empty number line could promote students to  use different strategies (direct subtraction, indirect addition, and indirect subtraction in solving subtraction problems. Based on these findings, it is recommended to apply RME in the teaching learning process to make it more meaningful for students. Keywords: Subtraction, Design Research, Realistic Mathematics Education, The Beads String, The Empty Number Line DOI: http://dx.doi.org/10.22342/jme.4.1.567.95-112

  10. Hadamard Multipliers and Abel Dual of Hardy Spaces

    Directory of Open Access Journals (Sweden)

    Paweł Mleczko

    2016-01-01

    Full Text Available The paper is devoted to the study of Hadamard multipliers of functions from the abstract Hardy classes generated by rearrangement invariant spaces. In particular the relation between the existence of such multiplier and the boundedness of the appropriate convolution operator on spaces of measurable functions is presented. As an application, the description of Hadamard multipliers into H∞ is given and the Abel type theorem for mentioned Hardy spaces is proved.

  11. Dual-energy subtraction radiography of the breast

    International Nuclear Information System (INIS)

    Asaga, Taro; Masuzawa, Chihiro; Kawahara, Satoru; Motohashi, Hisahiko; Okamoto, Takashi; Tamura, Nobuo

    1988-01-01

    Dual-energy projection radiography was applied to breast examination. To perform the dual-energy subtraction radiography using a digital radiography unit, high and low-energy exposures were made at an appropriate time interval under differing X-ray exposure conditions. Dual-energy subtraction radiography was performed in 41 cancer patients in whom the tumor shadow was equivocal or the border of cancer infiltration was not clearly demonstrated by compression mammography, and 15 patients with benign diseases such as fibrocystic disease, cyst and fibroadenoma. In 21 cases out of the 41 cancer patients, the dual-energy subtraction radiography clearly visualized the malignant tumor shadows and the border of cancer infiltration and the daughter nodules by removing the shadows of normal mammary gland. On the other hand, beign diseases such as fibrocystic disease and cyst could be diagnosed as such, because the tumor shadow and the irregularly concentrated image of mammary gland disappeared by the dual-energy subtraction. These results suggest that this new technique will be useful in examination of breast masses. (author)

  12. Dual-energy subtraction radiography of the breast

    Energy Technology Data Exchange (ETDEWEB)

    Asaga, Taro; Masuzawa, Chihiro; Kawahara, Satoru; Motohashi, Hisahiko; Okamoto, Takashi; Tamura, Nobuo

    1988-06-01

    Dual-energy projection radiography was applied to breast examination. To perform the dual-energy subtraction radiography using a digital radiography unit, high and low-energy exposures were made at an appropriate time interval under differing X-ray exposure conditions. Dual-energy subtraction radiography was performed in 41 cancer patients in whom the tumor shadow was equivocal or the border of cancer infiltration was not clearly demonstrated by compression mammography, and 15 patients with benign diseases such as fibrocystic disease, cyst and fibroadenoma. In 21 cases out of the 41 cancer patients, the dual-energy subtraction radiography clearly visualized the malignant tumor shadows and the border of cancer infiltration and the daughter nodules by removing the shadows of normal mammary gland. On the other hand, beign diseases such as fibrocystic disease and cyst could be diagnosed as such, because the tumor shadow and the irregularly concentrated image of mammary gland disappeared by the dual-energy subtraction. These results suggest that this new technique will be useful in examination of breast masses.

  13. Efek Multiplier Zakat terhadap Pendapatan di Provinsi DKI Jakarta

    OpenAIRE

    Al Arif, M. Nur Rianto

    2012-01-01

    The aim of this research is to analyse the multiplier effect of zakâh revenue in DKI Jakarta. A study case at Badan Amil Zakat, Infak, and Sadaqah (BAZIS) DKI Jakarta. Least square method is used to analyze the data. The coefficients will be used to calculate the multiplier effect of zakâh-revenue and it will be compared with the economy without zakah revenue. The results showed 2,522 multiplier effects of zakâh-revenue and 3.561 multiplier effect ofeconomic income without zakâh-revenue. Thi...

  14. Digital subtraction angiography system evaluation with phantoms

    International Nuclear Information System (INIS)

    Wenstrup, R.S.; Sweeney, K.P.; Scholz, F.J.

    1985-01-01

    Advances in digital subtraction angiography imaging demonstrate the need for critical evaluation of the performance of digital subtraction equipment. The design of a phantom set for noninvasive assessment of the imaging quality of digital subtraction equipment is described; components include a remotely controlled transport system and individual patterns to evaluate the contrast and detail properties of the image intensifier, low-contrast sensitivity and resolution of the system, geometric distortion of image, linearity, mechanical and electronic stability of equipment, and effects of bone and bowel gas on iodine perception. The performance of an add-on digital radiographic system is presented, along with radiation exposure levels at the image intensifier for a range of radiographic techniques

  15. Motion subtraction of the larynx using digital radiography

    International Nuclear Information System (INIS)

    Kumakawa, Kohzoh; Miyakawa, Kouichi

    1990-01-01

    The development of digital radiography (DR) has made it possible to analyze the contour of the laryngeal soft tissue structures in more detail than the conventional screen-film method. The authors first used the DR system for time subtraction of the larynx during inspiration and phonation. The images are acquired by means of frontal tomography of the larynx using the imaging plate during inspiration and phonation separately, and stored into the memory of the DR system. The thickness of the slices is 5.0 mm. Time subtraction between the mask image during inspiration and the live image during phonation is performed using digital processing on CRT. Superimposing the two images at the upper trachea and the thyroid cartilage of the same depth, makes it possible to measure movement of the vocal cord and false vocal cord quantitatively in three dimensions. The authors named this time subtraction as motion subtraction of the larynx. This motion subtraction image can be obtained by on-line digital processing without complicated development technique, but has so high spatial resolution. This image processing seems to be useful in functional radiographic analysis of laryngeal diseases. (author)

  16. Digital subtraction cerebral angiography by intraarterial injection: comparison with conventional angiography

    International Nuclear Information System (INIS)

    Brant-Zawadzki, M.; Gould, R.; Norman, D.; Newton, T.H.; Lane, B.

    1983-01-01

    For 4 months, a prototype digital subtraction system was used to obtain images of the cerebral vasculature after intraarterial contrast injections. In 12 instances, the intraarterial injections were recorded with both a digital subtraction unit and conventional direct magnification film-screen system. The digital subtraction and conventional film subtraction images were compared and graded for quality and information content by three skilled observers. In addition, quantitative measurements of contrast-detail performance and spatial resolution were obtained on both the digital system and the screen-film imaging chain. In a clinical setting, both the digital subtraction and conventional film-screen systems provided similar quality images and angiographic information. Contrast-detail curves demonstrated that digital subtraction angiography outperformed conventional film technique for low-contrast objects. Digital subtraction angiography also reduced the time required to obtain the angiogram, markedly reduced film cost, and lowered the contrast agent burden

  17. Development of digital subtraction system DAR-1200

    International Nuclear Information System (INIS)

    Kawai, Masumi; Shimizu, Yasumitsu; Ozaki, Takeshi; Sawada, Hiroshi; Uzuyama, Kazuhiro; Nishioka, Hiroyuki

    1989-01-01

    Digital subtraction angiography (DSA) has been of widespread use clinically, and it has attracted considerable attention in angiographic examination today. The merits of Shimadzu high resolution digital subtraction system DAR-1200 are reported in this paper. Furthermore, the principle and clinical usefullness of a new method of DSA called the Peak-Hold DSA are explained especially in details. (author)

  18. φ-Multipliers on Banach Algebras and Topological Modules

    OpenAIRE

    Adib, Marjan

    2015-01-01

    We prove some results concerning Arens regularity and amenability of the Banach algebra ${M}_{\\phi }(A)$ of all $\\phi $ -multipliers on a given Banach algebra $A$ . We also consider $\\phi $ -multipliers in the general topological module setting and investigate some of their properties. We discuss the $\\phi $ -strict and $\\phi $ -uniform topologies on ${M}_{\\phi }(A)$ . A characterization of $\\phi $ -multipliers on ${L}_{1}(G)$ -module ${L}_{p}(G)$ , where $G$ is a compact group, is given.

  19. Single electron based binary multipliers with overflow detection ...

    African Journals Online (AJOL)

    electron based device. Multipliers with overflow detection based on serial and parallel prefix computation algorithm are elaborately discussed analytically and designed. The overflow detection circuits works in parallel with a simplified multiplier to ...

  20. Advanced Background Subtraction Applied to Aeroacoustic Wind Tunnel Testing

    Science.gov (United States)

    Bahr, Christopher J.; Horne, William C.

    2015-01-01

    An advanced form of background subtraction is presented and applied to aeroacoustic wind tunnel data. A variant of this method has seen use in other fields such as climatology and medical imaging. The technique, based on an eigenvalue decomposition of the background noise cross-spectral matrix, is robust against situations where isolated background auto-spectral levels are measured to be higher than levels of combined source and background signals. It also provides an alternate estimate of the cross-spectrum, which previously might have poor definition for low signal-to-noise ratio measurements. Simulated results indicate similar performance to conventional background subtraction when the subtracted spectra are weaker than the true contaminating background levels. Superior performance is observed when the subtracted spectra are stronger than the true contaminating background levels. Experimental results show limited success in recovering signal behavior for data where conventional background subtraction fails. They also demonstrate the new subtraction technique's ability to maintain a proper coherence relationship in the modified cross-spectral matrix. Beam-forming and de-convolution results indicate the method can successfully separate sources. Results also show a reduced need for the use of diagonal removal in phased array processing, at least for the limited data sets considered.

  1. Sky Subtraction with Fiber-Fed Spectrograph

    Science.gov (United States)

    Rodrigues, Myriam

    2017-09-01

    "Historically, fiber-fed spectrographs had been deemed inadequate for the observation of faint targets, mainly because of the difficulty to achieve high accuracy on the sky subtraction. The impossibility to sample the sky in the immediate vicinity of the target in fiber instruments has led to a commonly held view that a multi-object fibre spectrograph cannot achieve an accurate sky subtraction under 1% contrary to their slit counterpart. The next generation of multi-objects spectrograph at the VLT (MOONS) and the planed MOS for the E-ELT (MOSAIC) are fiber-fed instruments, and are aimed to observed targets fainter than the sky continuum level. In this talk, I will present the state-of-art on sky subtraction strategies and data reduction algorithm specifically developed for fiber-fed spectrographs. I will also present the main results of an observational campaign to better characterise the sky spatial and temporal variations ( in particular the continuum and faint sky lines)."

  2. Isometric multipliers of a vector valued Beurling algebra on a ...

    Indian Academy of Sciences (India)

    Home; Journals; Proceedings – Mathematical Sciences; Volume 127; Issue 1. Isometric multipliers of a vector valued Beurling algebra on a discrete semigroup. Research Article Volume 127 Issue 1 February 2017 pp 109- ... Keywords. Weighted semigroup; multipliers of a semigroup; Beurling algebra; isometric multipliers.

  3. Economic Multipliers and Mega-Event Analysis

    OpenAIRE

    Victor Matheson

    2004-01-01

    Critics of economic impact studies that purport to show that mega-events such as the Olympics bring large benefits to the communities “lucky” enough to host them frequently cite the use of inappropriate multipliers as a primary reason why these impact studies overstate the true economic gains to the hosts of these events. This brief paper shows in a numerical example how mega-events may lead to inflated multipliers and exaggerated claims of economic benefits.

  4. AdS2 holographic dictionary

    International Nuclear Information System (INIS)

    Cvetič, Mirjam; Papadimitriou, Ioannis

    2016-01-01

    We construct the holographic dictionary for both running and constant dilaton solutions of the two dimensional Einstein-Maxwell-Dilaton theory that is obtained by a circle reduction from Einstein-Hilbert gravity with negative cosmological constant in three dimensions. This specific model ensures that the dual theory has a well defined ultraviolet completion in terms of a two dimensional conformal field theory, but our results apply qualitatively to a wider class of two dimensional dilaton gravity theories. For each type of solutions we perform holographic renormalization, compute the exact renormalized one-point functions in the presence of arbitrary sources, and derive the asymptotic symmetries and the corresponding conserved charges. In both cases we find that the scalar operator dual to the dilaton plays a crucial role in the description of the dynamics. Its source gives rise to a matter conformal anomaly for the running dilaton solutions, while its expectation value is the only non trivial observable for constant dilaton solutions. The role of this operator has been largely overlooked in the literature. We further show that the only non trivial conserved charges for running dilaton solutions are the mass and the electric charge, while for constant dilaton solutions only the electric charge is non zero. However, by uplifting the solutions to three dimensions we show that constant dilaton solutions can support non trivial extended symmetry algebras, including the one found by Compère, Song and Strominger http://dx.doi.org/10.1007/JHEP05(2013)152, in agreement with the results of Castro and Song http://arxiv.org/abs/1411.1948. Finally, we demonstrate that any solution of this specific dilaton gravity model can be uplifted to a family of asymptotically AdS 2 ×S 2 or conformally AdS 2 ×S 2 solutions of the STU model in four dimensions, including non extremal black holes. The four dimensional solutions obtained by uplifting the running dilaton solutions coincide

  5. Spin sensitivity of a channel electron multiplier

    International Nuclear Information System (INIS)

    Scholten, R.E.; McClelland, J.J.; Kelley, M.H.; Celotta, R.J.

    1988-01-01

    We report direct measurements of the sensitivity of a channel electron multiplier to electrons with different spin orientations. Four regions of the multiplier cone were examined using polarized electrons at 100-eV incident energy. Pulse counting and analog modes of operation were both investigated and in each case the observed spin effects were less than 0.5%

  6. Sociophysics of sexism: normal and anomalous petrie multipliers

    Science.gov (United States)

    Eliazar, Iddo

    2015-07-01

    A recent mathematical model by Karen Petrie explains how sexism towards women can arise in organizations where male and female are equally sexist. Indeed, the Petrie model predicts that such sexism will emerge whenever there is a male majority, and quantifies this majority bias by the ‘Petrie multiplier’: the square of the male/female ratio. In this paper—emulating the shift from ‘normal’ to ‘anomalous’ diffusion—we generalize the Petrie model to a stochastic Poisson model that accommodates heterogeneously sexist men and woman, and that extends the ‘normal’ quadratic Petrie multiplier to ‘anomalous’ non-quadratic multipliers. The Petrie multipliers span a full spectrum of behaviors which we classify into four universal types. A variation of the stochastic Poisson model and its Petrie multipliers is further applied to the context of cyber warfare.

  7. Implementation gap between the theory and practice of biodiversity offset multipliers

    DEFF Research Database (Denmark)

    Bull, Joseph William; Lloyd, Samuel P.; Strange, Niels

    2017-01-01

    literature on multipliers. Then, we collate data on multipliers implemented in practice, rep- resenting the most complete such assessment to date. Finally, we explore remaining design gaps relating to social, ethical, and governance considerations. Multiplier values should theoretically be tens or hundreds...... when considering, for example, ecological uncertainties. We propose even larger multipliers required to satisfy previously ignored considerations – including prospect theory, taboo trades, and power relationships. Conversely, our data analyses show that multipliers are smaller in practice, regularly...... for the implementation gap we have identified. At the same time, there is a need to explore when and where the social, ethical, and governance requirements for NNL reviewed here can be met through approaches other than multipliers....

  8. A study on the geometric correction for the digital subtraction radiograph

    International Nuclear Information System (INIS)

    Lim, Suk Young; Koh, Kwang Joon

    2001-01-01

    To develop a new subtraction program for registering digital images based on the correspondence of anatomic structures. The digital periapical images were obtained by Digora system with Rinn XCP equipment after translation of 1-16 mm, and rotation of 2-20 at the premolar and molar areas of the human dried mandible. The new subtraction program, NIH Image program and Emago/Advanced program were compared by the peak-signal -to noise ratio (PSNR). The new subtraction program was superior to NIH Images program and Emago/Advanced program up to 16 mm translation and horizontal angulation up to 4. The new subtraction program can be used for subtracting digital periapical images

  9. New stable multiply charged negative atomic ions in linearly polarized superintense laser fields

    International Nuclear Information System (INIS)

    Wei Qi; Kais, Sabre; Moiseyev, Nimrod

    2006-01-01

    Singly charged negative atomic ions exist in the gas phase and are of fundamental importance in atomic and molecular physics. However, theoretical calculations and experimental results clearly exclude the existence of any stable doubly-negatively-charged atomic ion in the gas phase, only one electron can be added to a free atom in the gas phase. In this report, using the high-frequency Floquet theory, we predict that in a linear superintense laser field one can stabilize multiply charged negative atomic ions in the gas phase. We present self-consistent field calculations for the linear superintense laser fields needed to bind extra one and two electrons to form He - , He 2- , and Li 2- , with detachment energies dependent on the laser intensity and maximal values of 1.2, 0.12, and 0.13 eV, respectively. The fields and frequencies needed for binding extra electrons are within experimental reach. This method of stabilization is general and can be used to predict stability of larger multiply charged negative atomic ions

  10. Model Checking Timed Automata with Priorities using DBM Subtraction

    DEFF Research Database (Denmark)

    David, Alexandre; Larsen, Kim Guldstrand; Pettersson, Paul

    2006-01-01

    In this paper we describe an extension of timed automata with priorities, and efficient algorithms to compute subtraction on DBMs (difference bounded matrices), needed in symbolic model-checking of timed automata with priorities. The subtraction is one of the few operations on DBMs that result...... in a non-convex set needing sets of DBMs for representation. Our subtraction algorithms are efficient in the sense that the number of generated DBMs is significantly reduced compared to a naive algorithm. The overhead in time is compensated by the gain from reducing the number of resulting DBMs since...... this number affects the performance of symbolic model-checking. The uses of the DBM subtraction operation extend beyond timed automata with priorities. It is also useful for allowing guards on transitions with urgent actions, deadlock checking, and timed games....

  11. Tables of compound-discount interest rate multipliers for evaluating forestry investments.

    Science.gov (United States)

    Allen L. Lundgren

    1971-01-01

    Tables, prepared by computer, are presented for 10 selected compound-discount interest rate multipliers commonly used in financial analyses of forestry investments. Two set of tables are given for each of the 10 multipliers. The first set gives multipliers for each year from 1 to 40 years; the second set gives multipliers at 5-year intervals from 5 to 160 years....

  12. Efek Multiplier Zakat Terhadap Pendapatan di Propinsi DKI Jakarta

    Directory of Open Access Journals (Sweden)

    M. Nur Rianto Al Arif

    2015-10-01

    Full Text Available The aim of this research is to analyze the multiplier effect of zakah revenue in DKI Jakarta, a study case at Badan Amil Zakat, Infak, and Shadaqah (BAZIS DKI Jakarta. Least square methods is used to analyze the data. The coefficient will be used to calculate the multiplier effect of zakah revenue and it will be compared with the economy without zakah revenue. The result showed 2,522 multiplier effects of zakah revenue and 3,561 multiplier effect of economic income without zakah revenue. This suggest that the management of zakah in BAZIS DKI Jakarta still can have a significant influence on the economyDOI: 10.15408/aiq.v4i1.2079

  13. Microchannel electron multiplier

    International Nuclear Information System (INIS)

    Beranek, I.; Janousek, L.; Vitovsky, O.

    1981-01-01

    A microchannel electron multiplier is described for detecting low levels of alpha, beta, soft X-ray and UV radiations. It consists of a glass tube or a system of tubes of various shapes made of common technological glass. The inner tube surface is provided with an active coat with photoemitter and secondary emitter properties. (B.S.)

  14. Evaluation of sacroiliitis: contrast-enhanced MRI with subtraction technique

    Energy Technology Data Exchange (ETDEWEB)

    Algin, Oktay; Gokalp, Gokhan; Baran, Bulent; Ocakoglu, Gokhan; Yazici, Zeynep [Uludag University, Medical Faculty, Department of Radiology, Gorukle, Bursa (Turkey)

    2009-10-15

    The purpose of the study was to investigate the diagnostic value of contrast-enhanced MRI using the subtraction technique in the detection of active sacroiliitis. Magnetic resonance imaging was performed in 8 asymptomatic volunteers and 50 patients with clinically suspected active sacroiliitis. On precontrast MR images, T1-weighted spin-echo images with and without fat saturation (T1WFS and T1W), STIR and 3D-FLASH images with fat saturation were obtained in the semicoronal plane using a 1.5 Tesla imager. Postcontrast MRI was performed using the same T1WFS sequence as before contrast injection for all volunteers and patients. Postcontrast images were subtracted from fat-suppressed precontrast images. Enhancement within the joint space and bone marrow was considered to demonstrate active sacroiliitis. In 50 patients (100 sacroiliac joints [SIJs]), 40 (76 SIJs) were considered to have active sacroiliitis based on MR images. Bone marrow edema was present in 33 patients (62 SIJs) on STIR images. Routine MRI allowed identification of contrast enhancement in SIJs on postcontrast T1WFS images in 31 patients (49 SIJs). Contrast enhancement was observed in 40 patients (76 SIJs) who were examined by MRI using the subtraction technique. Contrast enhancement was significantly more conspicuous on subtraction images than on non-subtracted postcontrast T1WFS images (Mann-Whitney U test, p<0.001). Contrast-enhanced MRI with subtraction technique may be useful for early detection of active sacroiliitis. (orig.)

  15. EFEK MULTIPLIER ZAKAT TERHADAP PENDAPATAN DI PROVINSI DKI JAKARTA

    Directory of Open Access Journals (Sweden)

    M. Nur Rianto Al Arif

    2016-02-01

    Full Text Available The aim of this research is to analyse the multiplier effect of zakâh revenue in DKI Jakarta. A study case at Badan Amil Zakat, Infak, and Sadaqah (BAZIS DKI Jakarta. Least square method is used to analyze the data. The coefficients will be used to calculate the multiplier effect of zakâh-revenue and it will  be compared with the economy without zakah revenue. The results showed 2,522 multiplier effects of zakâh-revenue and 3.561 multiplier effect ofeconomic income without zakâh-revenue. This suggests that the management of zakat in BAZIS Jakarta still can have a significant influence on the economy.DOI: 10.15408/aiq.v4i1.2533

  16. Digital subtraction radiographic evaluation of the standardize periapical intraoral radiographs

    International Nuclear Information System (INIS)

    Cho, Bong Hae; Nah, Kyung Soo

    1993-01-01

    The geometrically standardized intraoral radiographs using 5 occlusal registration material were taken serially from immediate, 1 day, 2, 4, 8, 12 and 16 weeks after making the bite blocks. The qualities of those subtracted images were evaluated to check the degree of reproducibility of each impression material. The results were as follows: 1. The standard deviations of the grey scales of the overall subtracted images were 4.9 for Exaflex, 7.2 for Pattern resin, 9.0 for Tooth Shade Acrylic, 12.2 for XCP only, 14.8 for Impregum. 2. The standard deviation of the grey scales of the overall subtracted images were grossly related to those of the localized horizontal line of interest. 3. Exaflex which showed the best subtracted image quality had 15 cases of straight, 14 cases of wave, 1 case of canyon shape. Impregum which showed the worst subtracted image quality had 4 cases of straight, 8 cases of wave, 18 cases of canyon shape respectively.

  17. Temporal subtraction in chest radiography: Automated assessment of registration accuracy

    International Nuclear Information System (INIS)

    Armato, Samuel G. III; Doshi, Devang J.; Engelmann, Roger; Croteau, Charles L.; MacMahon, Heber

    2006-01-01

    Radiologists routinely compare multiple chest radiographs acquired from the same patient over time to more completely understand changes in anatomy and pathology. While such comparisons are achieved conventionally through a side-by-side display of images, image registration techniques have been developed to combine information from two separate radiographic images through construction of a 'temporal subtraction image'. Although temporal subtraction images provide a powerful mechanism for the enhanced visualization of subtle change, errors in the clinical evaluation of these images may arise from misregistration artifacts that can mimic or obscure pathologic change. We have developed a computerized method for the automated assessment of registration accuracy as demonstrated in temporal subtraction images created from radiographic chest image pairs. The registration accuracy of 150 temporal subtraction images constructed from the computed radiography images of 72 patients was rated manually using a five-point scale ranging from '5-excellent' to '1-poor'; ratings of 3, 4, or 5 reflected clinically acceptable subtraction images, and ratings of 1 or 2 reflected clinically unacceptable images. Gray-level histogram-based features and texture measures are computed at multiple spatial scales within a 'lung mask' region that encompasses both lungs in the temporal subtraction images. A subset of these features is merged through a linear discriminant classifier. With a leave-one-out-by-patient training/testing paradigm, the automated method attained an A z value of 0.92 in distinguishing between temporal subtraction images that demonstrated clinically acceptable and clinically unacceptable registration accuracy. A second linear discriminant classifier yielded an A z value of 0.82 based on a feature subset selected from an independent database of digitized film images. These methods are expected to advance the clinical utility of temporal subtraction images for chest

  18. Multiplier convergent series and uniform convergence of mapping ...

    Indian Academy of Sciences (India)

    MS received 14 April 2011; revised 17 November 2012. Abstract. In this paper, we introduce the frame property of complex sequence sets and study the uniform convergence of nonlinear mapping series in β-dual of spaces consisting of multiplier convergent series. Keywords. Multiplier convergent series; mapping series. 1.

  19. Method and apparatus for performing digital intravenous subtraction angiography

    International Nuclear Information System (INIS)

    Stein, J.A.

    1986-01-01

    This invention relates to digital intravenous subtraction angiography (DISA), and more particularly concerns novel apparatus and techniques for providing high resolution angiograms with equipment that coacts with existing standard medical X-ray equipment. A typical medical X-ray generator provides low mA, continuous X-ray exposures illuminating a standard image intensifier producing an image scanned by a conventional television camera to produce a video signal. An analog-to-digital converter digitizes the signal, and adding means adds the digital frame signals together in real time to provide an intermediate digital signal representing the addition of 5 to 20 frames. Digital storage means store the intermediate image signals. Preferably there are two system memories with means for summing a subsequent intermediate image in the second memory while a previously-formed intermediate image is being transferred to disk storage

  20. Temperature Insensitive Current-Mode Four Quadrant Multiplier Using Single CFCTA

    Directory of Open Access Journals (Sweden)

    Tuntrakool Sunti

    2017-01-01

    Full Text Available A four quadrant multiplier of two current input signals using active building block, namely current follower cascaded transconductance amplifier (CFCTA is presented in this paper. The proposed multiplier consists of only single CFCTA without the use of any passive element. The presented circuit has low impedance at current input node and high impedance at current output node which is convenient for cascading in current mode circuit without the need of current buffer circuits. The output current can multiply two input currents with temperature insensitivity. Moreover, the magnitude of output current can be controlled electronically via DC bias current. With only single active building block, the presented multiplier is suitable for integrated circuit implementation for analog signal processing. Simulation results from a PSpice program are presented in order to demonstrate the multiplier proposed here.

  1. Cavallo's multiplier for in situ generation of high voltage

    Science.gov (United States)

    Clayton, S. M.; Ito, T. M.; Ramsey, J. C.; Wei, W.; Blatnik, M. A.; Filippone, B. W.; Seidel, G. M.

    2018-05-01

    A classic electrostatic induction machine, Cavallo's multiplier, is suggested for in situ production of very high voltage in cryogenic environments. The device is suitable for generating a large electrostatic field under conditions of very small load current. Operation of the Cavallo multiplier is analyzed, with quantitative description in terms of mutual capacitances between electrodes in the system. A demonstration apparatus was constructed, and measured voltages are compared to predictions based on measured capacitances in the system. The simplicity of the Cavallo multiplier makes it amenable to electrostatic analysis using finite element software, and electrode shapes can be optimized to take advantage of a high dielectric strength medium such as liquid helium. A design study is presented for a Cavallo multiplier in a large-scale, cryogenic experiment to measure the neutron electric dipole moment.

  2. On the usefulness of portal monitor unit subtraction in radiation therapy

    International Nuclear Information System (INIS)

    Kuperman, Vadim Y; Lubich, Leslie M

    2003-01-01

    In order to avoid additional dose to patients caused by portal imaging with megavoltage x-rays, portal monitor units (MUs) are frequently subtracted from the actual treatment MUs. This study examines the usefulness of portal MU subtraction in radiation therapy. For 11 prostate cancer patients treated with 23 MV photons, dose to prostate due to portal filming with 6 MV photons was determined. In all 11 patients subtraction of portal MU values from the actual treatment MUs resulted in a small underdosing of the prostate with an average treatment error of -0.5%. Portal filming without MU subtraction would cause small overdosing of the prostate with an average treatment error of 1.2%. The results of this study indicate that the benefits of portal MU subtraction are in doubt if (a) the energy of treatment x-rays is much higher than that of the portal x-rays and/or (b) when radiotherapy is performed with physical wedges. Based on the obtained results, we argue against unconditional use of the portal MU subtraction method to eliminate the dose from portal imaging

  3. A new registration method with voxel-matching technique for temporal subtraction images

    Science.gov (United States)

    Itai, Yoshinori; Kim, Hyoungseop; Ishikawa, Seiji; Katsuragawa, Shigehiko; Doi, Kunio

    2008-03-01

    A temporal subtraction image, which is obtained by subtraction of a previous image from a current one, can be used for enhancing interval changes on medical images by removing most of normal structures. One of the important problems in temporal subtraction is that subtraction images commonly include artifacts created by slight differences in the size, shape, and/or location of anatomical structures. In this paper, we developed a new registration method with voxel-matching technique for substantially removing the subtraction artifacts on the temporal subtraction image obtained from multiple-detector computed tomography (MDCT). With this technique, the voxel value in a warped (or non-warped) previous image is replaced by a voxel value within a kernel, such as a small cube centered at a given location, which would be closest (identical or nearly equal) to the voxel value in the corresponding location in the current image. Our new method was examined on 16 clinical cases with MDCT images. Preliminary results indicated that interval changes on the subtraction images were enhanced considerably, with a substantial reduction of misregistration artifacts. The temporal subtraction images obtained by use of the voxel-matching technique would be very useful for radiologists in the detection of interval changes on MDCT images.

  4. Combined nuclear and digital subtraction contrast arthrography in painful knee prosthesis

    International Nuclear Information System (INIS)

    Namasivayam, J.; Forrester, A.; Poon, F.W.; Cuthbert, G.F.; McKillop, J.H.; Bryan, A.S.

    1992-01-01

    The evaluation of a painful knee prosthesis remains a difficult problem for both orthopaedic surgeons and radiologists. We have compared digital subtraction arthrography with nuclear-arthrography in 7 patients with a painful knee prosthesis. Three patients showed a loose tibial component, demonstrated by both digital subtraction and nuclear arthrography. All 3 underwent revision of their prosthesis. One patient had an equivocal digital subtraction arthrogram and negative nuclear arthrogram, while both studies were negative in the 3 remaining patients. Nuclear arthrography is a simple procedure and can provide useful additional information when combined with digital subtraction arthrography. (orig.)

  5. Arthrography of painful hips following arthroplasty: Digital versus plain film subtraction

    Energy Technology Data Exchange (ETDEWEB)

    Walker, C W; FitzRandolph, R L; Dalrymple, G V [Arkansas Univ. for Medical Sciences, Little Rock, AR (USA). Dept. of Radiology John McClellan Memorial Veterans Hospital, Little Rock, AR (USA); Collins, D N [Arkansas Univ. for Medical Sciences, Little Rock, AR (USA). Dept. of Orthopedics John McClellan Memorial Veterans Hospital, Little Rock, AR (USA)

    1991-08-01

    Digital and manual subtraction images obtained during the arthrographic evaluation of 78 painful hip prostheses were reviewed retrospectively. Revision arthroplasty was performed in 53 of these cases, and the arthrographic and surgical findings were correlated. The digital and manual subtraction images were evaluated without knowledge of the surgical results using established criteria for component loosening. The difference between detection of femoral component loosening on digital as opposed to manual subtraction images was statistically significant (P < 0.05). This study demonstrates that digital subtraction improves the evaluation of femoral component loosening in painful hip prostheses. (orig./GDG).

  6. Use of signal subtraction methods in ESR dating of burned flint

    International Nuclear Information System (INIS)

    Porat, Naomi; Schwarcz, H.P.

    1991-01-01

    Geological samples of chert display some of the characteristics of electron spin resonance (ESR) signals of quartz. When chert is heated in a fireplace, most of these signals are annealed. The signals grow again in fire-heated chert buried in archaeological sites, as a result of internal and external radiation doses. The date of the heating event can be determined from the acquired dose (AD) and the dose rate. The E' and Al signals are best suited for dating. Although many cherts, when heated to a sufficient temperature, acquire a carbon radical (C) signal that largely obscures the E' signal, it can be subtracted from digitized spectra. The E' signal also appears to saturate at relatively low doses, restricting the time range of dating to between 200 and 600 ka, depending on the dose rates. The Al signal shows no saturation, but is also interfered with by organic signals, present in burnt and unburned flint. These can also be subtracted to reveal the ''pure'' Al signal. Applying the E' signal to date flint from Yabroud, we obtain an age between 100 and 125 ka, while both thermoluminescence (TL) dating of the flint and ESR dating of tooth enamel give 195 and 225 ka, respectively; the discrepancy may be due to an overestimate of the α-efficiency. At Nahr Ibrahim, the age (c. 80 ka) is consistent with archaeological estimates. (author)

  7. A cascaded three-phase symmetrical multistage voltage multiplier

    International Nuclear Information System (INIS)

    Iqbal, Shahid; Singh, G K; Besar, R; Muhammad, G

    2006-01-01

    A cascaded three-phase symmetrical multistage Cockcroft-Walton voltage multiplier (CW-VM) is proposed in this report. It consists of three single-phase symmetrical voltage multipliers, which are connected in series at their smoothing columns like string of batteries and are driven by three-phase ac power source. The smoothing column of each voltage multiplier is charged twice every cycle independently by respective oscillating columns and discharged in series through load. The charging discharging process completes six times a cycle and therefore the output voltage ripple's frequency is of sixth order of the drive signal frequency. Thus the proposed approach eliminates the first five harmonic components of load generated voltage ripples and sixth harmonic is the major ripple component. The proposed cascaded three-phase symmetrical voltage multiplier has less than half the voltage ripple, and three times larger output voltage and output power than the conventional single-phase symmetrical CW-VM. Experimental and simulation results of the laboratory prototype are given to show the feasibility of proposed cascaded three-phase symmetrical CW-VM

  8. [sup 99m]Tc-RBC subtraction scintigraphy; Assessmet of bleeding site and rate

    Energy Technology Data Exchange (ETDEWEB)

    Inagaki, Syoichi; Tonami, Syuichi; Yasui, Masakazu; Kuranishi, Makoto; Sugishita, Kouki; Nakamura, Mamoru (Toyama Medical and Pharmaceutical Univ. (Japan). Hospital)

    1994-03-01

    Sequential abdominal scintigrams with [sup 99m]Tc-labelled red blood cells (RBC) were subtracted for observing a site of gastrointestinal bleeding and calculating the bleeding rate. This method is technically very easy and can detect the site of bleeding with the minimum rate, as low as 0.2 ml/min., in a phantom experiment. In 23 cases with final diagnosis of gastrointestinal bleeding, conventional non-subtraction scintigraphy detected only 30% (7/23), but subtraction scintigraphy detected 61% (14/23). It was concluded that subtraction scintigraphy had higher sensitivity than conventional scintigraphy for early diagnosing bleeding. A combination of non-subtraction and subtraction scintigraphy is recommended to detect a site of gastrointestinal bleeding in a clinical setting. (author).

  9. Multiplier Accounting of Indian Mining Industry: The Application

    Science.gov (United States)

    Hussain, Azhar; Karmakar, Netai Chandra

    2017-10-01

    In the previous paper (Hussain and Karmakar in Inst Eng India Ser, 2014. doi: 10.1007/s40033-014-0058-0), the concepts of input-output transaction matrix and multiplier were explained in detail. Input-output multipliers are indicators used for predicting the total impact on an economy due to changes in its industrial demand and output which is calculated using transaction matrix. The aim of this paper is to present an application of the concepts with respect to the mining industry, showing progress in different sectors of mining with time and explaining different outcomes from the results obtained. The analysis shows that a few mineral industries saw a significant growth in their multiplier values over the years.

  10. Bone marrow edema pattern identification in patients with lytic bone lesions using digital subtraction angiography-like bone subtraction on large-area detector computed tomography.

    Science.gov (United States)

    Gondim Teixeira, Pedro Augusto; Hossu, Gabriela; Lecocq, Sophie; Razeto, Marco; Louis, Matthias; Blum, Alain

    2014-03-01

    The objective of this study was to evaluate the performance of digital subtraction angiography (DSA)-like bone subtraction with 2 different registration methods for the identification of bone marrow edema pattern (BMEP) in patients with lytic bone lesions, using magnetic resonance imaging as the criterion standard. Fifty-five patients with a lytic bone lesion were included in this prospective study with approval from the ethics committee. All patients underwent magnetic resonance imaging and low-dose computed tomographic (CT) perfusion after signing an informed consent. Two CT volumes were used for bone subtraction, which was performed with 2 different algorithms (rigid and nonrigid). Enhancement at the nonlytic bone marrow was considered as a sign of BMEP. Two readers evaluated the images blindly. The presence of BMEP on bone-subtracted CT images was evaluated subjectively and quantitatively. Image quality was assessed. Magnetic resonance imaging was used as the criterion standard. Using a rigid registration method, the sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of CT with DSA-like bone subtraction BMEP was 77%, 100%, 100%, 68%, and 85%, respectively. The interobserver agreement was good (κ, 0.782). Image quality was better using a nonrigid registration. With this algorithm, artifacts interfered with image interpretation in only 5% of cases. However, there was a noticeable drop in sensitivity and negative predictive value when a nonrigid algorithm was used: 56% and 52%, respectively. The interobserver agreement was average with a nonrigid subtraction algorithm. Computed tomography with DSA-like bone subtraction is sensitive and highly specific for the identification of BMEP associated with lytic bone lesions. Rigid registering should be preferred, but nonrigid algorithms can be used as a second option when artifacts interfere with image interpretation.

  11. Production processes of multiply charged ions by electron impact

    International Nuclear Information System (INIS)

    Oda, Nobuo

    1980-02-01

    First, are compared the foil or gas stripper and the ion sources utilizing electron-atom ionizing collisions, which are practically used or are under development to produce multiply charged ions. A review is made of the fundamental physical parameters such as successive ionization potentials and various ionization cross sections by electron impact, as well as the primary processes in multiply charged ion production. Multiply charged ion production processes are described for the different existing ion sources such as high temperature plasma type, ion-trapping type and discharge type. (author)

  12. The Growth Points of Regional Economy and Regression Estimation for Branch Investment Multipliers

    Directory of Open Access Journals (Sweden)

    Nina Pavlovna Goridko

    2018-03-01

    Full Text Available The article develops the methodology of using investment multipliers to identify growth points for a regional economy. The paper discusses various options for the assessment of multiplicative effects caused by investments in certain sectors of the economy. All calculations are carried out on the example of economy of the Republic of Tatarstan for the period 2005–2015. The instrument of regression modeling using the method of least squares, permits to estimate sectoral and cross-sectoral investment multipliers in the economy of the Republic of Tatarstan. Moreover, this method allows to assess the elasticity of gross output of regional economy and its individual sectors depending on investment in various sectors of the economy. Calculations results allowed to identify three growth points of the economy of the Republic of Tatarstan. They are mining industry, manufacturing industry and construction. The success of a particular industry or sub-industry in a country or a region should be measured not only by its share in macro-system’s gross output or value added, but also by the multiplicative effect that investments in the industry have on the development of other industries, on employment and on general national or regional product. In recent years, the growth of the Russian was close to zero. Thus, it is crucial to understand the structural consequences of the increasing investments in various sectors of the Russian economy. In this regard, the problems solved in the article are relevant for a number of countries and regions with a similar economic situation. The obtained results can be applied for similar estimations of investment multipliers as well as multipliers of government spending, and other components of aggregate demand in various countries and regions to identify growth points. Investments in these growth points will induce the greatest and the most evident increment of the outcome from the macro-system’s economic activities.

  13. Added sugars in kids' meals from chain restaurants.

    Science.gov (United States)

    Scourboutakos, Mary J; Semnani-Azad, Zhila; L'Abbé, Mary R

    2016-06-01

    To analyze the added sugars in kids' meals from Canadian chain restaurants in relation to the World Health Organization's proposed sugar recommendation (less than 5% of total daily calories should come from added sugars) and current recommendation (less than 10% of total daily calories should come from added sugars). Total sugar levels were retrieved from the websites of 10 fast-food and 7 sit-down restaurants in 2010. The added sugar levels in 3178 kids' meals from Canadian chain restaurants were calculated in 2014 (in Toronto, Canada) by subtracting all naturally occurring sugars from the total sugar level. The average amount of added sugars in restaurant kids' meals (25 ± 0.36 g) exceeded the WHO's proposed daily recommendation for sugar intake. There was a wide range of added sugar levels in kids' meals ranging from 0 g to 114 g. 50% of meals exceeded the WHO's proposed daily sugar recommendation, and 19% exceeded the WHO's current daily sugar recommendation. There is a wide range of sugar levels in kids' meals from restaurants, and many contain more than a day's worth of sugar.

  14. The study of myocardial ischemic quality with weighted-subtraction-bull's-eye analysis

    International Nuclear Information System (INIS)

    Chen Wuduan; Tian Jiahe; Hou Qingtian

    1993-01-01

    Weighted-Subtraction-Bull's-eye analysis was studied in 33 normal subjects and 58 patients with coronary artery disease after dipyridamole 99m Tc-MIBI myocardial SPECT imaging. Two kinds of Bull's-eye were produced: (1) subtract rest from 1.2 times dipyridamole from 1.2 times rest Bull's-eye; (2) subtract dipyridamole Bull's-eye. The results showed that the weighted-subtraction-Bull's-eye could clearly displayed the location and puality of ischemic myocardium. And also 74% segments showed so called combined ischemic i.e the blood perfusion reduced, increased and sustained simultaneously after dipyridamole. Therefore weighted-subtraction-Bull's-eye analysis had provided a new method for determination of the quality of ischemia

  15. The Multiply Handicapped Child.

    Science.gov (United States)

    Wolf, James M., Ed.; Anderson, Robert M., Ed.

    Articles presented in the area of the medical and educational challenge of the multiply handicapped child are an overview of the problem, the increasing challenge, congenital malformations, children whose mothers had rubella, prematurity and deafness, the epidemiology of reproductive casualty, and new education for old problems. Discussions of…

  16. Digital subtraction cardiopulmonary angiography using FCR (Fuji computed radiography)

    International Nuclear Information System (INIS)

    Tanimura, Shigeo; Tomoyasu, Hiroshi; Banba, Jiro; Masaki, Mikio; Kanno, Yukio; Abe, Kazuo

    1987-01-01

    Digital subtraction cardiopulmonary angiography using FCR was performed on 46 patients including lung cancer, mediastinal tumor, giant bullous formation and others. The images of digital subtraction for pulmonary artery, pulmonary vein and thoracic aorta were studied by comparing to the conventional pulmonary angiogram. Good images of pulmonary artery due to digital subtraction were obtained in 80 % of the 45 cases. This method needed only half volume of contrast media compared to the conventional for obtaining good images and thus reduced side effect. Therefore this method seems to be an usefull pre-operative examination in various chest diseases, especially in case of lung cancer. (author)

  17. N-jettiness Subtractions for NNLO QCD calculations

    International Nuclear Information System (INIS)

    Gaunt, Jonathan R.; Stahlhofen, Maximilian; Tackmann, Frank J.; Walsh, Jonathan R.; California Univ., CA

    2015-05-01

    We present a subtraction method utilizing the N-jettiness observable, Τ N , to perform QCD calculations for arbitrary processes at next-to-next-to-leading order (NNLO). Our method employs soft-collinear effective theory (SCET) to determine the IR singular contributions of N-jet cross sections for Τ N → 0, and uses these to construct suitable Τ N -subtractions. The construction is systematic and economic, due to being based on a physical observable. The resulting NNLO calculation is fully differential and in a form directly suitable for combining with resummation and parton showers. We explain in detail the application to processes with an arbitrary number of massless partons at lepton and hadron colliders together with the required external inputs in the form of QCD amplitudes and lower-order calculations. We provide explicit expressions for the Τ N -subtractions at NLO and NNLO. The required ingredients are fully known at NLO, and at NNLO for processes with two external QCD partons. The remaining NNLO ingredient for three or more external partons can be obtained numerically with existing NNLO techniques. As an example, we employ our method to obtain the NNLO rapidity spectrum for Drell-Yan and gluon-fusion Higgs production. We discuss aspects of numerical accuracy and convergence and the practical implementation. We also discuss and comment on possible extensions, such as more-differential subtractions, necessary steps for going to N 3 LO, and the treatment of massive quarks.

  18. Value of blood-pool subtraction in cardiac indium-111-labeled platelet imaging

    Energy Technology Data Exchange (ETDEWEB)

    Machac, J.; Vallabhajosula, S.; Goldman, M.E.; Goldsmith, S.J.; Palestro, C.; Strashun, A.; Vaquer, R.; Phillips, R.A.; Fuster, V. (Mt. Sinai Medical Center, New York, NY (USA))

    1989-09-01

    Blood-pool subtraction has been proposed to enhance {sup 111}In-labeled platelet imaging of intracardiac thrombi. We tested the accuracy of labeled platelet imaging, with and without blood-pool subtraction, in ten subjects with cardiac thrombi of varying age, eight with endocarditis being treated with antimicrobial therapy and ten normal controls. Imaging was performed early after labeled platelet injection (24 hr or less) and late (48 hr or more). Blood-pool subtraction was carried out. All images were graded subjectively by four experienced, blinded readers. Detection accuracy was measured by the sensitivity at three fixed levels of specificity estimated from receiver operator characteristic curve analysis and tested by three-way analysis of variance. Detection accuracy was generally improved on delayed images. Blood-pool subtraction did not improve accuracy. Although blood-pool subtraction increased detection sensitivity, this was offset by decreased specificity. For this population studied, blood-pool subtraction did not improve subjective detection of abnormal platelet deposition by 111In platelet imaging.

  19. Value of blood-pool subtraction in cardiac indium-111-labeled platelet imaging

    International Nuclear Information System (INIS)

    Machac, J.; Vallabhajosula, S.; Goldman, M.E.; Goldsmith, S.J.; Palestro, C.; Strashun, A.; Vaquer, R.; Phillips, R.A.; Fuster, V.

    1989-01-01

    Blood-pool subtraction has been proposed to enhance 111 In-labeled platelet imaging of intracardiac thrombi. We tested the accuracy of labeled platelet imaging, with and without blood-pool subtraction, in ten subjects with cardiac thrombi of varying age, eight with endocarditis being treated with antimicrobial therapy and ten normal controls. Imaging was performed early after labeled platelet injection (24 hr or less) and late (48 hr or more). Blood-pool subtraction was carried out. All images were graded subjectively by four experienced, blinded readers. Detection accuracy was measured by the sensitivity at three fixed levels of specificity estimated from receiver operator characteristic curve analysis and tested by three-way analysis of variance. Detection accuracy was generally improved on delayed images. Blood-pool subtraction did not improve accuracy. Although blood-pool subtraction increased detection sensitivity, this was offset by decreased specificity. For this population studied, blood-pool subtraction did not improve subjective detection of abnormal platelet deposition by 111In platelet imaging

  20. Ictal cerebral perfusion patterns in partial epilepsy: SPECT subtraction

    International Nuclear Information System (INIS)

    Lee, Hyang Woon; Hong, Seung Bong; Tae, Woo Suk; Kim, Sang Eun; Seo, Dae Won; Jeong, Seung Cheol; Yi, Ji Young; Hong, Seung Chyul

    2000-01-01

    To investigate the various ictal perfusion patterns and find the relationships between clinical factors and different perfusion patterns. Interictal and ictal SPECT and SPECT subtraction were performed in 61 patients with partial epilepsy. Both positive images showing ictal hyperperfusion and negative images revealing ictal hypoperfusion were obtained by SPECT subtraction. The ictal perfusion patterns of subtracted SPECT were classified into focal hyperperfusion, hyperperfusion-plus, combined hyperperfusion-hypoperfusion, and focal hypoperfusion only. The concordance rates with epileptic focus were 91.8% in combined analysis of ictal hyperperfusion and hypoperfusion images of subtracted SPECT, 85.2% in hyperperfusion images only of subtracted SPECT, and 68.9% in conventional ictal SPECT analysis. Ictal hypoperfusion occurred less frequently in temporal lobe epilepsy (TLE) than extratemporal lobe epilepsy. Mesial temporal hyperperfusion alone was seen only in mesial TLE while lateral temporal hyperperfusion alone was observed only in neocortical TLE. Hippocampal sclerosis had much lower incidence of ictal hypoperfusion than any other pathology. Some patients showed ictal hypoperfusion at epileptic focus with ictal hyperperfusion in the neighboring brain regions where ictal discharges propagated. Hypoperfusion as well as hyperperfusion in ictal SPECT should be considered for localizing epileptic focus. Although the mechanism of ictal hypoperfusion could be an intra-ictal early exhaustion of seizure focus or a steal phenomenon by the propagation of ictal discharges to adjacent brain areas, further study is needed to elucidate it.=20

  1. Ictal cerebral perfusion patterns in partial epilepsy: SPECT subtraction

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hyang Woon; Hong, Seung Bong; Tae, Woo Suk; Kim, Sang Eun; Seo, Dae Won; Jeong, Seung Cheol; Yi, Ji Young; Hong, Seung Chyul [Sungkyunkwan Univ. School of Medicine, Seoul (Korea, Republic of)

    2000-06-01

    To investigate the various ictal perfusion patterns and find the relationships between clinical factors and different perfusion patterns. Interictal and ictal SPECT and SPECT subtraction were performed in 61 patients with partial epilepsy. Both positive images showing ictal hyperperfusion and negative images revealing ictal hypoperfusion were obtained by SPECT subtraction. The ictal perfusion patterns of subtracted SPECT were classified into focal hyperperfusion, hyperperfusion-plus, combined hyperperfusion-hypoperfusion, and focal hypoperfusion only. The concordance rates with epileptic focus were 91.8% in combined analysis of ictal hyperperfusion and hypoperfusion images of subtracted SPECT, 85.2% in hyperperfusion images only of subtracted SPECT, and 68.9% in conventional ictal SPECT analysis. Ictal hypoperfusion occurred less frequently in temporal lobe epilepsy (TLE) than extratemporal lobe epilepsy. Mesial temporal hyperperfusion alone was seen only in mesial TLE while lateral temporal hyperperfusion alone was observed only in neocortical TLE. Hippocampal sclerosis had much lower incidence of ictal hypoperfusion than any other pathology. Some patients showed ictal hypoperfusion at epileptic focus with ictal hyperperfusion in the neighboring brain regions where ictal discharges propagated. Hypoperfusion as well as hyperperfusion in ictal SPECT should be considered for localizing epileptic focus. Although the mechanism of ictal hypoperfusion could be an intra-ictal early exhaustion of seizure focus or a steal phenomenon by the propagation of ictal discharges to adjacent brain areas, further study is needed to elucidate it.

  2. Integrated optic vector-matrix multiplier

    Science.gov (United States)

    Watts, Michael R [Albuquerque, NM

    2011-09-27

    A vector-matrix multiplier is disclosed which uses N different wavelengths of light that are modulated with amplitudes representing elements of an N.times.1 vector and combined to form an input wavelength-division multiplexed (WDM) light stream. The input WDM light stream is split into N streamlets from which each wavelength of the light is individually coupled out and modulated for a second time using an input signal representing elements of an M.times.N matrix, and is then coupled into an output waveguide for each streamlet to form an output WDM light stream which is detected to generate a product of the vector and matrix. The vector-matrix multiplier can be formed as an integrated optical circuit using either waveguide amplitude modulators or ring resonator amplitude modulators.

  3. Digital subtraction imaging in cardiac investigations

    International Nuclear Information System (INIS)

    Partridge, J.B.; Dickinson, D.F.

    1984-01-01

    The role of digital subtraction imaging (DSI) in the investigation of heart disease in patients of all ages, including neonates, was evaluated by the addition of a continuous fluoroscopy system to an existing, single-plane catheterisation laboratory. In some situations, DSI provided diagnostic images where conventional radiography could not and, in general, provided images of comparable quality to cineangiography. The total dose of contrast medium was usually less than that which would have been required for biplane cineangiography and the dose of radiation was always less. Digital subtraction imaging can make a significant contribution to the investigation of congenital heart disease and has some useful features in the study of acquired heart disease. (author)

  4. Multipliers for the Absolute Euler Summability of Fourier Series

    Indian Academy of Sciences (India)

    In this paper, the author has investigated necessary and sufficient conditions for the absolute Euler summability of the Fourier series with multipliers. These conditions are weaker than those obtained earlier by some workers. It is further shown that the multipliers are best possible in certain sense.

  5. Multiplier less high-speed squaring circuit for binary numbers

    Science.gov (United States)

    Sethi, Kabiraj; Panda, Rutuparna

    2015-03-01

    The squaring operation is important in many applications in signal processing, cryptography etc. In general, squaring circuits reported in the literature use fast multipliers. A novel idea of a squaring circuit without using multipliers is proposed in this paper. Ancient Indian method used for squaring decimal numbers is extended here for binary numbers. The key to our success is that no multiplier is used. Instead, one squaring circuit is used. The hardware architecture of the proposed squaring circuit is presented. The design is coded in VHDL and synthesised and simulated in Xilinx ISE Design Suite 10.1 (Xilinx Inc., San Jose, CA, USA). It is implemented in Xilinx Vertex 4vls15sf363-12 device (Xilinx Inc.). The results in terms of time delay and area is compared with both modified Booth's algorithm and squaring circuit using Vedic multipliers. Our proposed squaring circuit seems to have better performance in terms of both speed and area.

  6. AutoDipole - Automated generation of dipole subtraction terms

    International Nuclear Information System (INIS)

    Hasegawa, K.; Uwer, P.

    2009-11-01

    We present an automated generation of the subtraction terms for next-to-leading order QCD calculations in the Catani-Seymour dipole formalism. For a given scattering process with n external particles our Mathematica package generates all dipole terms, allowing for bothmassless and massive dipoles. The numerical evaluation of the subtraction terms proceeds with MadGraph, which provides Fortran code for the necessary scattering amplitudes. Checks of the numerical stability are discussed. (orig.)

  7. AutoDipole - Automated generation of dipole subtraction terms

    Energy Technology Data Exchange (ETDEWEB)

    Hasegawa, K.; Uwer, P. [Humboldt-Universitaet, Berlin (Germany). Inst. fuer Physik; Moch, S. [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany)

    2009-11-15

    We present an automated generation of the subtraction terms for next-to-leading order QCD calculations in the Catani-Seymour dipole formalism. For a given scattering process with n external particles our Mathematica package generates all dipole terms, allowing for bothmassless and massive dipoles. The numerical evaluation of the subtraction terms proceeds with MadGraph, which provides Fortran code for the necessary scattering amplitudes. Checks of the numerical stability are discussed. (orig.)

  8. ECG-gating in non-cardiac digital subtraction angiography

    International Nuclear Information System (INIS)

    Gattoni, F.; Baldini, V.; Cairo, F.

    1987-01-01

    This paper reports the results of the ECG-gating in non-cardiac digital subtraction angiography (DSA). One hundred and fifteen patients underwent DSA (126 examinations); ECG-gating was applied in 66/126 examinations: images recorded at 70% of R wave were subtracted. Artifacts produced by vascular movements were evaluated in all patients: only 40 examinations, carried out whithout ECG-gating, showed vascular artifacts. The major advantage of the ECG-gated DSA is the more efficent subtraction because of the better images superimposition: therefore, ECG-gating can be clinically helpful. On the contrary, it could be a problem in arrhytmic or bradycardic patients. ECG-gating is helpful in DSA imaging of the thoracic and abdominal aorta and of the cervical and renal arteries. In the examinations of peripheral vessels of the limbs it is not so efficent as in the trunk or in the neck

  9. Automating dipole subtraction

    Energy Technology Data Exchange (ETDEWEB)

    Hasegawa, K.; Moch, S. [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany); Uwer, P. [Karlsruhe Univ. (T.H.) (Germany). Inst. fuer Theoretische Teilchenphysik

    2008-07-15

    We report on automating the Catani-Seymour dipole subtraction which is a general procedure to treat infrared divergences in real emission processes at next-to-leading order in QCD. The automatization rests on three essential steps: the creation of the dipole terms, the calculation of the color linked squared Born matrix elements, and the evaluation of different helicity amplitudes. The routines have been tested for a number of complex processes, such as the real emission process gg{yields}t anti tggg. (orig.)

  10. Automating dipole subtraction

    International Nuclear Information System (INIS)

    Hasegawa, K.; Moch, S.; Uwer, P.

    2008-07-01

    We report on automating the Catani-Seymour dipole subtraction which is a general procedure to treat infrared divergences in real emission processes at next-to-leading order in QCD. The automatization rests on three essential steps: the creation of the dipole terms, the calculation of the color linked squared Born matrix elements, and the evaluation of different helicity amplitudes. The routines have been tested for a number of complex processes, such as the real emission process gg→t anti tggg. (orig.)

  11. Colourful FKS subtraction

    CERN Document Server

    Frixione, Stefano

    2011-01-01

    I formulate in a colour-friendly way the FKS method for the computation of QCD cross sections at the next-to-leading order accuracy. This is achieved through the definition of subtraction terms for squared matrix elements, constructed with single colour-dressed or pairs of colour-ordered amplitudes. The latter approach relies on the use of colour flows, is exact to all orders in $N$, and is thus particularly suited to being organized as a systematic expansion in 1/N.

  12. Electronic de-multipliers II (ring-shape systems)

    International Nuclear Information System (INIS)

    Raievski, V.

    1948-09-01

    This report describes a new type of ring-shape fast electronic counter (de-multiplier) with a resolution capacity equivalent to the one made by Regener (Rev. of Scientific Instruments USA 1946, 17, 180-89) but requiring two-times less electronic valves. This report follows the general description of electronic de-multipliers made by J. Ailloud (CEA--001). The ring comprises 5 flip-flop circuits with two valves each. The different elements of the ring are calculated with enough details to allow the transfer of this calculation to different valve types. (J.S.)

  13. Nonenhanced magnetic resonance angiography (MRA) of the calf arteries at 3 Tesla: intraindividual comparison of 3D flow-dependent subtractive MRA and 2D flow-independent non-subtractive MRA.

    Science.gov (United States)

    Knobloch, Gesine; Lauff, Marie-Teres; Hirsch, Sebastian; Schwenke, Carsten; Hamm, Bernd; Wagner, Moritz

    2016-12-01

    To prospectively compare 3D flow-dependent subtractive MRA vs. 2D flow-independent non-subtractive MRA for assessment of the calf arteries at 3 Tesla. Forty-two patients with peripheral arterial occlusive disease underwent nonenhanced MRA of calf arteries at 3 Tesla with 3D flow-dependent subtractive MRA (fast spin echo sequence; 3D-FSE-MRA) and 2D flow-independent non-subtractive MRA (balanced steady-state-free-precession sequence; 2D-bSSFP-MRA). Moreover, all patients underwent contrast-enhanced MRA (CE-MRA) as standard-of-reference. Two readers performed a per-segment evaluation for image quality (4 = excellent to 0 = non-diagnostic) and severity of stenosis. Image quality scores of 2D-bSSFP-MRA were significantly higher compared to 3D-FSE-MRA (medians across readers: 4 vs. 3; p Tesla with significantly higher image quality and diagnostic accuracy compared to 3D flow-dependent subtractive MRA (3D-FSE-MRA). • 2D flow-independent non-subtractive MRA (2D-bSSFP-MRA) is a robust NE-MRA technique at 3T • 2D-bSSFP-MRA outperforms 3D flow-dependent subtractive MRA (3D-FSE-MRA) as NE-MRA of calf arteries • 2D-bSSFP-MRA is a promising alternative to CE-MRA for calf PAOD evaluation.

  14. Principal parameters of classical multiply charged ion sources

    International Nuclear Information System (INIS)

    Winter, H.; Wolf, B.H.

    1974-01-01

    A review is given of the operational principles of classical multiply charged ion sources (operating sources for intense beams of multiply charged ions using discharge plasmas; MCIS). The fractional rates of creation of multiply charged ions in MCIS plasmas cannot be deduced from the discharge parameters in a simple manner; they depend essentially on three principal parameters, the density and energy distribution of the ionizing electrons, and the confinement time of ions in the ionization space. Simple discharge models were used to find relations between principal parameters, and results of model calculations are compared to actually measured charge state density distributions of extracted ions. Details of processes which determine the energy distribution of ionizing electrons (heating effects), confinement times of ions (instabilities), and some technical aspects of classical MCIS (cathodes, surface processes, conditioning, life time) are discussed

  15. Digital subtraction angiography (DSA)

    International Nuclear Information System (INIS)

    Ludwig, J.W.; Eikelboom, B.C.; Van Schaik, C.C.; Taams, A.J.; Teeuwen, C.

    1985-01-01

    Besides the non-invasive techniques, angiography remains essential. The disadvantages of angiography are the complexity of the procedure and the possibility of complications. Digital subtraction angiography (DSA) is a considerable improvement in the examination of vessels. In DSA, subtraction combined with enhancement of the signals allows the use of intravenous injection to obtain good images of the arteries. However, when the contrast material is supplied intravenously, a rather large amount of contrast material is necessary to obtain images of good quality. Quantities of 30-40 cc of contrast material are required. The advantage of the intravenous injection of contrast material rather than the use of a catheter to deliver the contrast material in loco is that it is almost non-invasive thus circumventing the complications caused by catheter manipulation in the arterial system. This makes it possible to apply this method on an out-patient basis. DSA can also be applied with intra-arterial selective injection of the contrast material. In this case, the strong enhancement with DSA allows the use of a small quantity of contrast material while still obtaining images of the vessels with good contrast definition

  16. Dimension of the c-nilpotent multiplier of Lie algebras

    Indian Academy of Sciences (India)

    Abstract. The purpose of this paper is to derive some inequalities for dimension of the c-nilpotent multiplier of finite dimensional Lie algebras and their factor Lie algebras. We further obtain an inequality between dimensions of c-nilpotent multiplier of Lie algebra L and tensor product of a central ideal by its abelianized factor ...

  17. Subleading power corrections for N -jettiness subtractions

    Science.gov (United States)

    Moult, Ian; Rothen, Lorena; Stewart, Iain W.; Tackmann, Frank J.; Zhu, Hua Xing

    2017-04-01

    The N -jettiness observable TN provides a way of describing the leading singular behavior of the N -jet cross section in the τ =TN/Q →0 limit, where Q is a hard interaction scale. We consider subleading-power corrections in the τ ≪1 expansion, and employ soft-collinear effective theory to obtain analytic results for the dominant αsτ ln τ and αs2τ ln3τ subleading terms for thrust in e+e- collisions and 0-jettiness for q q ¯-initiated Drell-Yan-like processes at hadron colliders. These results can be used to significantly improve the numerical accuracy and stability of the N -jettiness subtraction technique for performing fixed-order calculations at next-to-leading order and next-to-next-to-leading order. They reduce the size of missing power corrections in the subtractions by an order of magnitude. We also point out that the precise definition of N -jettiness has an important impact on the size of the power corrections and thus the numerical accuracy of the subtractions. The sometimes employed definition of N -jettiness in the hadronic center-of-mass frame suffers from power corrections that grow exponentially with rapidity, causing the power expansion to deteriorate away from central rapidity. This degradation does not occur for the original N -jettiness definition, which explicitly accounts for the boost of the Born process relative to the frame of the hadronic collision, and has a well-behaved power expansion throughout the entire phase space. Integrated over rapidity, using this N -jettiness definition in the subtractions yields another order of magnitude improvement compared to employing the hadronic-frame definition.

  18. Physical principles of cardiac digital subtraction angiography

    International Nuclear Information System (INIS)

    Buonocore, E.; Pavlicek, W.

    1986-01-01

    Advances in the applications of computers with standard radiologic equipment have resulted in the development of electronic, or so-called ''film-less'' imaging. This technique, discussed by the authors, has become of particular value in the visualization of the central vascular system and has become known as digital subtraction angiography (DSA). Commercial products have become increasingly available and are capable of converting T.V. signals, obtained by conventional fluorography, to a computed array of digital values. Addition, subtraction, and averaging of this data, result in images with adequate signal-to-noise ratios that achieve detection of low concentrations of contrast media not possible with conventional screen film techniques. Computer subtraction of unnecessary background information improves the conspicuity of the opacified vessels to permit detection of vascular structures containing a concentration of no more than 1-3 percent of contrast media. This improved visualization is possible even with intravenous peripheral injections or reduced amounts of contrast media given intraarterially. With either method of contrast media administration, DSDA has become an excellent means of anatomic demonstration of the heart and great vessels with decreased morbidity and at lower cost

  19. Probabilistic Model-based Background Subtraction

    DEFF Research Database (Denmark)

    Krüger, Volker; Anderson, Jakob; Prehn, Thomas

    2005-01-01

    is the correlation between pixels. In this paper we introduce a model-based background subtraction approach which facilitates prior knowledge of pixel correlations for clearer and better results. Model knowledge is being learned from good training video data, the data is stored for fast access in a hierarchical...

  20. Evaluation of seismic forces due to anchor movement and inertial effects in multiply supported piping systems

    International Nuclear Information System (INIS)

    Burdisso, R.A.; Singh, M.P.

    1987-01-01

    The results indicate that various ad hoc approaches used for calculating the dynamic and pseudo static responses of a multiply supported secondary system do not provide the correct estimates of the response. The approaches can under- or over-estimate the true response. Also, the contribution of the dynamic, pseudo static responses to the total response is likely to vary with the type of response, member in which the response is calculated, characteristics of the two systems and the input. No generalizations can be made about the relative contribution of these components. Furthermore, the contribution of the correlation between the dynamic and pseudo static response component to the total response can be very significant. It can not be correctly included by the currently used approximate rules for the combination of dynamic and pseudo static responses. In summary, to obtain the correct response for a multiply supported secondary system, one must use proper inputs at the support as well as employ analytically rational approach to calculate the response from the inputs. (orig./HP)

  1. ADS National Programmes: China

    International Nuclear Information System (INIS)

    2015-01-01

    In China the conceptual study of an ADS concept which lasted for about five years ended in 1999. As one project of the National Basic Research Programme of China (973 Programme) in energy domain, which is sponsored by the China Ministry of Science and Technology (MOST), a five year programme of fundamental research of ADS physics and related technology was launched in 2000 and passed national review at the end of 2005. From 2007, another five year 973 Programme Key Technology Research of Accelerator Driven Subcritical System for Nuclear waste Transmutation started. The research activities were focused on HPPA physics and technology, reactor physics of external source driven subcritical assembly, nuclear data base and material study. For HPPA, a high current injector consisting of an ECR ion source, LEBT and an RFQ accelerating structure of 3.5 MeV has been built and were being improved. In reactor physics study, a series of neutron multiplication experimental study has been carrying out. The VENUS I facility has been constructed as the basic experimental platform for neutronics study in ADS blanket. VENUS I a zero power subcritical neutron multiplying assembly driven by external neutron produced by a pulsed neutron generator or 252Cf neutron source. The theoretical, experimental and simulation studies on nuclear data, material properties and nuclear fuel circulation related to ADS are carried out in order to provide the database for ADS system analysis. China Institute of Atomic Energy (CIAE), Institute of High Energy Physics (IHEP) and other Chinese institutes carried out the MOST project together. Besides CIAE, China Academy of Science (CAS) pays more and more attention to Advanced Nuclear Fuel Cycles (ANFC). A large programme of ANFC, including ADS and Th based nuclear fuel cycle, has been launched by CAS

  2. Effect of the equity multiplier indicator in companies according the sectors

    Directory of Open Access Journals (Sweden)

    Lenka Lízalová

    2013-01-01

    Full Text Available Managers carry out the demand of the owners to maximise the rentability of invested capital with regards to the taken risk. The tool that evaluates the suitability to indebt in order to reach a higher rentability is the equity multiplier indicator. An analysis of the multiplier was carried out on 10 years of data from 456 Czech companies. Based on the data from these companies the influence of two components of the multiplier, which characterise the influence of indebtedness on the return on equity, was analysed. These components are “financial leverage” and “interest burden”, these having an antagonistic effect. The low variability of the equity multiplier is apparent in the companies of the administrative and support service sector and it is also relatively low in the companies of the agriculture, forestry and fishing sector; on the contrary, in for example the professional, scientific and technical activities and the sector of water, sewage and waste there are companies with higher variability of the equity multiplier. The paper identifies companies (in view of their sector specialization inclining to a larger utility of debts to increase the return on equity. The largest equity is reached in companies of the construction sector; the lowest effect of the multiplier is to be found in companies of the agriculture sector. The resulting value of the multiplier is to a large extent determined by the financial leverage indicator, to a lower extent and at the same time negatively by the interest burden indicator.

  3. Physics of subcritical multiplying regions and experimental validation

    International Nuclear Information System (INIS)

    Salvatores, M.

    1996-01-01

    The coupling of a particle accelerator with a spallation target and with a subcritical multiplying region has been proposed in the fifties and is called here a hybrid system. This article gives some ideas about the energetic balance of such a system. The possibilities of experimental validation of some properties of a subcritical multiplying region by using MASURCA facility at CEA-Cadarache are examined. The results of a preliminary experiment called MUSE are presented. (A.C.)

  4. Digital image comparison by subtracting contextual transformations—percentile rank order differentiation

    Science.gov (United States)

    Wehde, M. E.

    1995-01-01

    The common method of digital image comparison by subtraction imposes various constraints on the image contents. Precise registration of images is required to assure proper evaluation of surface locations. The attribute being measured and the calibration and scaling of the sensor are also important to the validity and interpretability of the subtraction result. Influences of sensor gains and offsets complicate the subtraction process. The presence of any uniform systematic transformation component in one of two images to be compared distorts the subtraction results and requires analyst intervention to interpret or remove it. A new technique has been developed to overcome these constraints. Images to be compared are first transformed using the cumulative relative frequency as a transfer function. The transformed images represent the contextual relationship of each surface location with respect to all others within the image. The process of differentiating between the transformed images results in a percentile rank ordered difference. This process produces consistent terrain-change information even when the above requirements necessary for subtraction are relaxed. This technique may be valuable to an appropriately designed hierarchical terrain-monitoring methodology because it does not require human participation in the process.

  5. Late iodine enhancement computed tomography with image subtraction for assessment of myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Tanabe, Yuki; Kido, Teruhito; Kurata, Akira; Kouchi, Takanori; Fukuyama, Naoki; Yokoi, Takahiro; Miyagawa, Masao; Mochizuki, Teruhito [Ehime University Graduate School of Medicine, Department of Radiology, Toon City, Ehime (Japan); Uetani, Teruyoshi [Department of Cardiology, Ehime University Graduate School of Medicine, Toon City, Ehime (Japan); Yamashita, Natsumi [National Hospital Organization Shikoku Cancer Center, Department of Clinical Biostatistics, Section of Cancer Prevention and Epidemiology, Clinical Research Center, Matsuyama City, Ehime (Japan)

    2018-03-15

    To evaluate the feasibility of image subtraction in late iodine enhancement CT (LIE-CT) for assessment of myocardial infarction (MI). A comprehensive cardiac CT protocol and late gadolinium enhancement MRI (LGE-MRI) was used to assess coronary artery disease in 27 patients. LIE-CT was performed after stress CT perfusion (CTP) and CT angiography. Subtraction LIE-CT was created by subtracting the mask volume of the left ventricle (LV) cavity from the original LIE-CT using CTP dataset. The %MI volume was quantified as the ratio of LIE to entire LV volume, and transmural extent (TME) of LIE was classified as 0%, 1-24%, 25-49%, 50-74% or 75-100%. These results were compared with LGE-MRI using the Spearman rank test, Bland-Altman method and chi-square test. One hundred twenty-five (29%) of 432 segments were positive on LGE-MRI. Correlation coefficients for original and subtraction LIE-CT to LGE-MRI were 0.79 and 0.85 for %MI volume. Concordances of the 5-point grading scale between original and subtraction LIE-CT with LGE-MRI were 75% and 84% for TME; concordance was significantly improved using the subtraction technique (p <0.05). Subtraction LIE-CT allowed more accurate assessment of MI extent than the original LIE-CT. (orig.)

  6. Decoupling Subtraction Conserving Full Gauge Symmetries : Particles and Fields

    OpenAIRE

    Noriyasu, OHTSUBO; Hideo, MIYATA; Department of Phycics, Kanazawa Technical College; Department of Information Science, Kanazawa Institute of Technolgy

    1984-01-01

    A new subtraction scheme (^^^) which realizes the decoupling and conserves the symmetries of full gauge group simultaneously, is proposed. One particle irreducible Green's functions subtracted by ^^^ reveal the effective low energy symmetries at -p^2≪M^2 and the full symmetries at -p^2≫M^2, where M denotes a heavy mass. Also discussed are conditions in order to carry out ^^^ under two-loop approximation.

  7. Multiply charged ions from solid substances with the mVINIS Ion Source

    International Nuclear Information System (INIS)

    Dragani, I; Nedeljkovi, T; Jovovi, J; Siljegovic, M; Dobrosavljevic, A

    2007-01-01

    We have used the well known metal-ions-from-volatile-compounds (MIVOC) method at the mVINIS Ion Source to produce the multiply charged ion beams form solid substances. Based on this method the very intense and stable multiply charged ion beams of several solid substances having the high melting points were extracted. The ion yields and the spectra of multiply charged ion beams obtained from solid materials like Fe and Hf will be presented. We have utilized the multiply charged ion beams from solid substances to irradiate the polymers, fullerenes and glassy carbon at the low energy channel for modification of materials

  8. Why Multiply by "g"?

    Science.gov (United States)

    Nelson, Jane Bray

    2012-01-01

    As a new physics teacher, I was explaining how to find the weight of an object sitting on a table near the surface of the Earth. It bothered me when a student asked, "The object is not accelerating so why do you multiply the mass of the object by the acceleration due to gravity?" I answered something like, "That's true, but if the table were not…

  9. Intravenous digital subtraction angiography of transplanted kidney artery

    International Nuclear Information System (INIS)

    Tessier, J.P; Teyssou, H.; Verdier, J.P.; Tison, E.; Meyblum, J.; Marchal, M.

    1986-01-01

    Results of 351 intravenous digital subtraction angiographs (AN) of transplanted kidneys emphasized reliability of this examination for detection of renal artery stenosis. A prospective study of 219 patients (188 interpretable AN) showed significant stenosis of grafted artery in 22% of cases: 17% of the 126 patients with normal blood pressure and 34% of the 62 cases of hypertension. Digital subtraction allows, with a single injection, assessment of renal artery, nephrogram and excretory cavities, but it is not a substitute for conventional intravenous urography 1 to 2 months after grafting [fr

  10. Lagrangian relaxation technique in power systems operation planning: Multipliers updating problem

    Energy Technology Data Exchange (ETDEWEB)

    Ruzic, S. [Electric Power Utility of Serbia, Belgrade (Yugoslavia)

    1995-11-01

    All Lagrangian relaxation based approaches to the power systems operation planning have an important common part: the Lagrangian multipliers correction procedure. It is the subject of this paper. Different approaches presented in the literature are discussed and an original method for the Lagrangian multipliers updating is proposed. The basic idea of this new method is to update Lagrangian multipliers trying to satisfy Khun-Tucker optimality conditions. Instead of the dual function maximization the `distance of optimality function` is defined and minimized. If Khun-Tucker optimality conditions are satisfied the value of this function is in range (-1,0); otherwise the function has a big positive value. This method called `the distance of optimality method` takes into account future changes in planning generations due to the Lagrangian multipliers updating. The influence of changes in a multiplier associated to one system constraint to the satisfaction of some other system requirements is also considered. The numerical efficiency of the proposed method is analyzed and compared with results obtained using the sub-gradient technique. 20 refs, 2 tabs

  11. Digital subtraction radiography in the study of the lacrimal system

    International Nuclear Information System (INIS)

    Falaschi, F.; Pieri, L.; Perri, G.; Signorini, G.; Genovese Ebert, F.

    1988-01-01

    The authors emphasize the usefulness of digital dacrycystography (DCG), as compared with various current technoques. Utilizing a radiographic unit equipped with a video-fluoroscopic system and interfaced to a digital video-processor, several digitalized images are acquired before, during and after the injection of contrast medium. Final images are obtained by subtraction of suitable pairs of source frames. Twenty-six patients affected by epiphora have been examined so far. In 21 cases digital subtraction DCG allowed an accurate visualization of the lacrimal system; in the other five patients the amount of information was acceptable. This methodology allows the assessment of both the normal anatomy of the lacrimal passages and their pathological patterns, such as obstructions, stenoses, fistulas, chronic dacrycystites, lacrimal stones. The examination is easy and quick to perform, with no discomfort for the patient. Digital subtraction DCG proves thus to be a very valuable technique thanks to its possible electronic elaboration - i.e. the subtraction and the magnification of images - to its better contrast resolution, and to the possibility it yields of dynamic studies under radioscopic control

  12. Deflation Expectation Financial System and Decline in Money Multiplier(in Japanese)

    OpenAIRE

    IIDA Yasuyuki

    2005-01-01

    The money multiplier is in a continuous downward trend now since the bubble burst, and, in addition, the trend has accelerated after 2000. It is said that the monetary policy is difficult because the money multiplier has declined. To think about the monetary policy for the future, we should think about the cause of the decline of the money multiplier. I want to verify two typical hypotheses "Deflation Expectation Hypothesis" and "Financial System Hypothesis" for the decision of the money mult...

  13. Detection of intracranial aneurysms using three-dimensional multidetector-row CT angiography: Is bone subtraction necessary?

    International Nuclear Information System (INIS)

    Hwang, Seung Bae; Kwak, Hyo Sung; Han, Young Min; Chung, Gyung Ho

    2011-01-01

    Purpose: The aim of this study was to evaluate the usefulness of three-dimensional CT angiography (3D CTA) with bone subtraction in a comparison with 3D CTA without bone subtraction for the detection of intracranial aneurysms. Materials and methods: Among 337 consecutive patients who had intracranial aneurysms detected on 3D CTA, 170 patients who underwent digital subtraction angiography (DSA) were included in the study. CTA was performed with a 16-slice multidetector-row CT (MDCT) scanner. We created the 3D reconstruction images with and without bone subtraction by using the volume rendering technique. Three neuroradiologists in a blinded fashion interpreted both 3D CTA images with and without bone subtraction. The diagnostic accuracy of both techniques was evaluated using the alternative free-response receiver operating characteristic (ROC) analysis. The sensitivity and positive predictive value were also evaluated. Results: A total of 200 aneurysms (size: 2-23 mm) were detected in 170 patients. The area under the receiver operating characteristic curve (Az) for 3D CTA with bone subtraction (mean, Az = 0.933) was significantly higher than that for 3D CTA without bone subtraction (mean, Az = 0.879) for all observers (P < 0.05). The sensitivity of 3D CTA with bone subtraction for three observers was 90.0, 92.0 and 92.5%, respectively, while the sensitivity of 3D CTA without bone subtraction was 83.5, 83.5 and 87.5%, respectively. No significant difference in positive predictive value was observed between the two modalities. Conclusions: 3D CTA with bone subtraction showed significantly higher diagnostic accuracy for the detection of intracranial aneurysms as compared to 3D CTA without bone subtraction.

  14. Incidence of ischemic lesions in diffusion-weighted imaging after transbrachial digital subtraction angiography

    International Nuclear Information System (INIS)

    Aschenbach, R.; Majeed, A.; Eger, C.; Basche, S.; Kerl, J.M.; Vogl, T.J.

    2008-01-01

    Purpose: to evaluate the frequency of ischemia after transbrachial digital subtraction angiography under ambulant conditions using diffusion-weighted imaging. Materials and methods: 200 patients were included in a prospective study design and received transbrachial digital subtraction angiography under ambulant conditions. Before and after digital subtraction angiography, diffusion-weighted imaging of the brain was performed. Results: in our study population no new lesions were found in diffusion-weighted imaging after digital subtraction angiography during the 3-hour window after angiography. One new lesion was found 3 days after angiography as a late onset complication. Therefore, the frequency of neurological complications is at the level of the confidence interval of 0 - 1.5%. Conclusion: the transbrachial approach under ambulant conditions is a safe method for digital subtraction angiography resulting in a low rate of ischemic lesions in diffusion-weighted imaging. (orig.)

  15. Digital subtraction angiography in traumatology

    International Nuclear Information System (INIS)

    Steudel, A.; Harder, T.; Lackner, K.; Schneider, B.; Orellano, L.; Bonn Univ.; Bonn Univ.

    1986-01-01

    The methods, indications and results of digital subtraction angiography in traumatology are presented, based on 56 examinations. The different use of intravenous or intraarterial DSA will be discussed with respect to expanding and localisation of traumatic vascular injury. DSA is recommended as the method of choice for follow-up after vascular reconstructive procedure. (orig.) [de

  16. Subtractive Structural Modification of Morpho Butterfly Wings.

    Science.gov (United States)

    Shen, Qingchen; He, Jiaqing; Ni, Mengtian; Song, Chengyi; Zhou, Lingye; Hu, Hang; Zhang, Ruoxi; Luo, Zhen; Wang, Ge; Tao, Peng; Deng, Tao; Shang, Wen

    2015-11-11

    Different from studies of butterfly wings through additive modification, this work for the first time studies the property change of butterfly wings through subtractive modification using oxygen plasma etching. The controlled modification of butterfly wings through such subtractive process results in gradual change of the optical properties, and helps the further understanding of structural optimization through natural evolution. The brilliant color of Morpho butterfly wings is originated from the hierarchical nanostructure on the wing scales. Such nanoarchitecture has attracted a lot of research effort, including the study of its optical properties, its potential use in sensing and infrared imaging, and also the use of such structure as template for the fabrication of high-performance photocatalytic materials. The controlled subtractive processes provide a new path to modify such nanoarchitecture and its optical property. Distinct from previous studies on the optical property of the Morpho wing structure, this study provides additional experimental evidence for the origination of the optical property of the natural butterfly wing scales. The study also offers a facile approach to generate new 3D nanostructures using butterfly wings as the templates and may lead to simpler structure models for large-scale man-made structures than those offered by original butterfly wings. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Semigroups of Herz-Schur multipliers

    DEFF Research Database (Denmark)

    Knudby, Søren

    2014-01-01

    function (see Theorem 1.2). It is then shown that a (not necessarily proper) generator of a semigroup of Herz–Schur multipliers splits into a positive definite kernel and a conditionally negative definite kernel. We also show that the generator has a particularly pleasant form if and only if the group...

  18. Multiplied Environmental Literacy. Final Report.

    Science.gov (United States)

    Buethe, Chris

    This booklet presents a pupil-oriented program designed to increase the environmental literacy of teachers and students in Indiana schools through a programmed multiplier effect. Junior and senior high school science teachers were prepared to teach students the meanings of 44 selected environmental terms and related concepts. Those teachers then…

  19. Digital subtraction angiography: first 900 cases

    International Nuclear Information System (INIS)

    Rodgers, H.

    1984-01-01

    The diagnostic technique of digital subtraction angiography (DSA) is briefly outlined. The operational and technical experiences with a DR-960 DSA system used in the examination of the first 900 cases at St. Thomas' Hospital, London are described. (U.K.)

  20. Thallium-201 and technetium-99m pertechnetate subtraction scintigraphy in patients with hyperparathyroidism

    International Nuclear Information System (INIS)

    Kuwashima, Shigeko; Koizumi, Mitsuru; Goto, Masafumi; Nomura, Toshiharu; Fujioka, Mutsuhisa; Watari, Tsutomu

    1992-01-01

    A reliable technique for detecting and localizing abnormal parathyroid tissue has been a persistent problem. We evaluated thallium-technetium (Tl/Tc) subtraction scintigraphy in 16 patients with clinical biochemical evidence of hyperparathyroidism prior to other diagnostic methods and surgery. Seven patients had surgery and were confirmed to have parathyroid adenoma or hyperplasia. The other methods included ultrasonography (US) in 6 patients, computed tomography (CT) in 10 patients, magnetic resonance imaging (MRI) in 8 patients, and bone scintigraphy in 7 patients. In patients who had several imaging modalities, the detection rate was significantly better for Tl/Tc subtraction scan than for US, CT or MRI. Bote scintigraphy, though not so sensitive as Tl/Tc subtraction studies, was an important tool for evaluating metabolic bone disorder including hyperparathyroidism and renal osteodystrophy. Thus, Tl/Tc subtraction scan is more useful for diagnosis when hyperparathyroidism is suspected if both Tl/Tc subtraction scan and bone scan are performed. The detectability depended on the mass size, and detection of abnormal glands was greater for adenoma than for hyperplasia. The results suggest that Tl/Tc subtraction scan is a simple, non-invasive and useful tool for locating parathyroid abnormality even when compared with MRI. (author)

  1. Subtraction by Distraction: Publishing Value-Added Estimates of Teachers by Name Hinders Education Reform

    Science.gov (United States)

    Epstein, Diana; Miller, Raegen T.

    2011-01-01

    In August 2010 the "Los Angeles Times" published a special report on their website featuring performance ratings for nearly 6,000 Los Angeles Unified School District teachers. The move was controversial because the ratings were based on so-called value-added estimates of teachers' contributions to student learning. As with most…

  2. Color Addition and Subtraction Apps

    Science.gov (United States)

    Ruiz, Frances; Ruiz, Michael J.

    2015-01-01

    Color addition and subtraction apps in HTML5 have been developed for students as an online hands-on experience so that they can more easily master principles introduced through traditional classroom demonstrations. The evolution of the additive RGB color model is traced through the early IBM color adapters so that students can proceed step by step…

  3. Power corrections in the N-jettiness subtraction scheme

    Energy Technology Data Exchange (ETDEWEB)

    Boughezal, Radja [High Energy Physics Division, Argonne National Laboratory,Argonne, IL 60439 (United States); Liu, Xiaohui [Department of Physics, Beijing Normal University,Beijing, 100875 (China); Center of Advanced Quantum Studies, Beijing Normal University,Beijing, 100875 (China); Center for High-Energy Physics, Peking University,Beijing, 100871 (China); Maryland Center for Fundamental Physics, University of Maryland,College Park, MD 20742 (United States); Petriello, Frank [Department of Physics & Astronomy, Northwestern University,Evanston, IL 60208 (United States); High Energy Physics Division, Argonne National Laboratory,Argonne, IL 60439 (United States)

    2017-03-30

    We discuss the leading-logarithmic power corrections in the N-jettiness subtraction scheme for higher-order perturbative QCD calculations. We compute the next-to-leading order power corrections for an arbitrary N-jet process, and we explicitly calculate the power correction through next-to-next-to-leading order for color-singlet production for both qq̄ and gg initiated processes. Our results are compact and simple to implement numerically. Including the leading power correction in the N-jettiness subtraction scheme substantially improves its numerical efficiency. We discuss what features of our techniques extend to processes containing final-state jets.

  4. A simple digital subtraction angiographic instrument

    International Nuclear Information System (INIS)

    Ando, Hiroshi; Kobayashi, Tsuyoshi; Imai, Yutaka; Yanagishita, Akira

    1983-01-01

    A digital subtraction angiographic instrument was manufactured using a conventional x-ray TV for gastrointestinal series and a computer for processing of nuclear medical data. The results of visualization of the aorta and its primary branches were reviewed with demonstrable cases. (Chiba, N.)

  5. Effect of the channel electron multiplier connection diagram on its parameters

    International Nuclear Information System (INIS)

    Ajnbund, M.R.

    1976-01-01

    Basic alternatives of connection of a channel electron multiplier are described. A dependence of a gain factor and amplitude resolution of the channel electron multiplier upon its connection diagram is studied. The studies have shown that the maximum gain factor is typical of an open-output circuit where the signal is recorded from the anode of the channel electron multiplier at a potential with respect to the channel outlet. The highest amplitude resolution is inherent in a separate-anode circuit where the loading resistance is connected directly to the channel outlet

  6. Summation and subtraction using a modified autoshaping procedure in pigeons.

    Science.gov (United States)

    Ploog, Bertram O

    2008-06-01

    A modified autoshaping paradigm (significantly different from those previously reported in the summation literature) was employed to allow for the simultaneous assessment of stimulus summation and subtraction in pigeons. The response requirements and the probability of food delivery were adjusted such that towards the end of training 12 of 48 trials ended in food delivery, the same proportion as under testing. Stimuli (outlines of squares of three sizes and colors: A, B, and C) were used that could be presented separately or in any combination of two or three stimuli. Twelve of the pigeons (summation groups) were trained with either A, B, and C or with AB, BC, and CA, and tested with ABC. The remaining 12 pigeons (subtraction groups) received training with ABC but were tested with A, B, and C or with AB, BC, and CA. These groups were further subdivided according to whether stimulus elements were presented either in a concentric or dispersed manner. Summation did not occur; subtraction occurred in the two concentric groups. For interpretation of the results, configural theory, the Rescorla-Wagner model, and the composite-stimulus control model were considered. The results suggest different mechanisms responsible for summation and subtraction.

  7. Appearance of the canine meninges in subtraction magnetic resonance images.

    Science.gov (United States)

    Lamb, Christopher R; Lam, Richard; Keenihan, Erin K; Frean, Stephen

    2014-01-01

    The canine meninges are not visible as discrete structures in noncontrast magnetic resonance (MR) images, and are incompletely visualized in T1-weighted, postgadolinium images, reportedly appearing as short, thin curvilinear segments with minimal enhancement. Subtraction imaging facilitates detection of enhancement of tissues, hence may increase the conspicuity of meninges. The aim of the present study was to describe qualitatively the appearance of canine meninges in subtraction MR images obtained using a dynamic technique. Images were reviewed of 10 consecutive dogs that had dynamic pre- and postgadolinium T1W imaging of the brain that was interpreted as normal, and had normal cerebrospinal fluid. Image-anatomic correlation was facilitated by dissection and histologic examination of two canine cadavers. Meningeal enhancement was relatively inconspicuous in postgadolinium T1-weighted images, but was clearly visible in subtraction images of all dogs. Enhancement was visible as faint, small-rounded foci compatible with vessels seen end on within the sulci, a series of larger rounded foci compatible with vessels of variable caliber on the dorsal aspect of the cerebral cortex, and a continuous thin zone of moderate enhancement around the brain. Superimposition of color-encoded subtraction images on pregadolinium T1- and T2-weighted images facilitated localization of the origin of enhancement, which appeared to be predominantly dural, with relatively few leptomeningeal structures visible. Dynamic subtraction MR imaging should be considered for inclusion in clinical brain MR protocols because of the possibility that its use may increase sensitivity for lesions affecting the meninges. © 2014 American College of Veterinary Radiology.

  8. Fiscal Multipliers in Ukraine

    OpenAIRE

    Pritha Mitra; Tigran Poghosyan

    2015-01-01

    Amid renewed crisis, falling tax revenues, and rising debt, Ukraine faces serious fiscal consolidation needs. Durable fiscal adjustment can support economic confidence and rebuild buffers but what is its overall impact on growth? How effective are revenue versus spending instruments? Does current or capital spending have a larger impact? Applying a structural vector autoregressive model, this paper finds that Ukraine’s near-term revenue and spending multipliers are well below one. In the medi...

  9. IR subtraction schemes. Integrating the counterterms at NNLO in QCD

    Energy Technology Data Exchange (ETDEWEB)

    Bolzoni, Paolo; Somogyi, Gabor

    2010-06-15

    We briefly review a subtraction scheme for computing radiative corrections to QCD jet cross sections that can be defined at any order in perturbation theory. Hereafter we discuss the computational methods used to evaluate analytically and numerically the integrated counterterms arising from such a subtraction scheme. Basically these methods the Mellin-Barnes (MB) representations technique together with the harmonic summation and the sector decomposition. (orig.)

  10. IR subtraction schemes. Integrating the counterterms at NNLO in QCD

    International Nuclear Information System (INIS)

    Bolzoni, Paolo; Somogyi, Gabor

    2010-06-01

    We briefly review a subtraction scheme for computing radiative corrections to QCD jet cross sections that can be defined at any order in perturbation theory. Hereafter we discuss the computational methods used to evaluate analytically and numerically the integrated counterterms arising from such a subtraction scheme. Basically these methods the Mellin-Barnes (MB) representations technique together with the harmonic summation and the sector decomposition. (orig.)

  11. Digital subtraction arthrography in preoperative evaluation of painful total hip arthroplasty

    International Nuclear Information System (INIS)

    Ginai, A.Z.; Biezen, F.C. van; Kint, P.A.M.; Oei, H.Y.; Hop, W.C.J.

    1996-01-01

    Digital subtraction arthrograms, scintigrams and plain radiographs of 70 consecutive patients who underwent revision hip arthroplasty were scored individually and in masked fashion for the presence or absence of features indicating loosening of femoral and/or acetabular components. The operative findings acted as the gold standard. Digital subtraction arthrography was best for predicting a loose acetabular component, while no significant additional predictive value was found for plain radiographs and scintigraphy. Digital subtraction arthrography was also the most important modality for predicting a loose femoral component, while the plain radiograph was of significant additional value and scintigraphy was of no additional value on multivariate analysis. (orig./MG)

  12. 3D temporal subtraction on multislice CT images using nonlinear warping technique

    Science.gov (United States)

    Ishida, Takayuki; Katsuragawa, Shigehiko; Kawashita, Ikuo; Kim, Hyounseop; Itai, Yoshinori; Awai, Kazuo; Li, Qiang; Doi, Kunio

    2007-03-01

    The detection of very subtle lesions and/or lesions overlapped with vessels on CT images is a time consuming and difficult task for radiologists. In this study, we have developed a 3D temporal subtraction method to enhance interval changes between previous and current multislice CT images based on a nonlinear image warping technique. Our method provides a subtraction CT image which is obtained by subtraction of a previous CT image from a current CT image. Reduction of misregistration artifacts is important in the temporal subtraction method. Therefore, our computerized method includes global and local image matching techniques for accurate registration of current and previous CT images. For global image matching, we selected the corresponding previous section image for each current section image by using 2D cross-correlation between a blurred low-resolution current CT image and a blurred previous CT image. For local image matching, we applied the 3D template matching technique with translation and rotation of volumes of interests (VOIs) which were selected in the current and the previous CT images. The local shift vector for each VOI pair was determined when the cross-correlation value became the maximum in the 3D template matching. The local shift vectors at all voxels were determined by interpolation of shift vectors of VOIs, and then the previous CT image was nonlinearly warped according to the shift vector for each voxel. Finally, the warped previous CT image was subtracted from the current CT image. The 3D temporal subtraction method was applied to 19 clinical cases. The normal background structures such as vessels, ribs, and heart were removed without large misregistration artifacts. Thus, interval changes due to lung diseases were clearly enhanced as white shadows on subtraction CT images.

  13. Karatsuba-Ofman Multiplier with Integrated Modular Reduction for GF(2m

    Directory of Open Access Journals (Sweden)

    CUEVAS-FARFAN, E.

    2013-05-01

    Full Text Available In this paper a novel GF(2m multiplier based on Karatsuba-Ofman Algorithm is presented. A binary field multiplication in polynomial basis is typically viewed as a two steps process, a polynomial multiplication followed by a modular reduction step. This research proposes a modification to the original Karatsuba-Ofman Algorithm in order to integrate the modular reduction inside the polynomial multiplication step. Modular reduction is achieved by using parallel linear feedback registers. The new algorithm is described in detail and results from a hardware implementation on FPGA technology are discussed. The hardware architecture is described in VHDL and synthesized for a Virtex-6 device. Although the proposed field multiplier can be implemented for arbitrary finite fields, the targeted finite fields are recommended for Elliptic Curve Cryptography. Comparing other KOA multipliers, our proposed multiplier uses 36% less area resources and improves the maximum delay in 10%.

  14. Real-time out-of-plane artifact subtraction tomosynthesis imaging using prior CT for scanning beam digital x-ray system

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Meng, E-mail: mengwu@stanford.edu [Department of Electrical Engineering, Stanford University, Stanford, California 94305 (United States); Fahrig, Rebecca [Department of Radiology, Stanford University, Stanford, California 94305 (United States)

    2014-11-01

    Purpose: The scanning beam digital x-ray system (SBDX) is an inverse geometry fluoroscopic system with high dose efficiency and the ability to perform continuous real-time tomosynthesis in multiple planes. This system could be used for image guidance during lung nodule biopsy. However, the reconstructed images suffer from strong out-of-plane artifact due to the small tomographic angle of the system. Methods: The authors propose an out-of-plane artifact subtraction tomosynthesis (OPAST) algorithm that utilizes a prior CT volume to augment the run-time image processing. A blur-and-add (BAA) analytical model, derived from the project-to-backproject physical model, permits the generation of tomosynthesis images that are a good approximation to the shift-and-add (SAA) reconstructed image. A computationally practical algorithm is proposed to simulate images and out-of-plane artifacts from patient-specific prior CT volumes using the BAA model. A 3D image registration algorithm to align the simulated and reconstructed images is described. The accuracy of the BAA analytical model and the OPAST algorithm was evaluated using three lung cancer patients’ CT data. The OPAST and image registration algorithms were also tested with added nonrigid respiratory motions. Results: Image similarity measurements, including the correlation coefficient, mean squared error, and structural similarity index, indicated that the BAA model is very accurate in simulating the SAA images from the prior CT for the SBDX system. The shift-variant effect of the BAA model can be ignored when the shifts between SBDX images and CT volumes are within ±10 mm in the x and y directions. The nodule visibility and depth resolution are improved by subtracting simulated artifacts from the reconstructions. The image registration and OPAST are robust in the presence of added respiratory motions. The dominant artifacts in the subtraction images are caused by the mismatches between the real object and the prior CT

  15. The Use of Procedural Knowledge in Simple Addition and Subtraction Problems

    Science.gov (United States)

    Fayol, Michel; Thevenot, Catherine

    2012-01-01

    In a first experiment, adults were asked to solve one-digit additions, subtractions and multiplications. When the sign appeared 150 ms before the operands, addition and subtraction were solved faster than when the sign and the operands appeared simultaneously on screen. This priming effect was not observed for multiplication problems. A second…

  16. Temporal subtraction of chest radiographs compensating pose differences

    Science.gov (United States)

    von Berg, Jens; Dworzak, Jalda; Klinder, Tobias; Manke, Dirk; Kreth, Adrian; Lamecker, Hans; Zachow, Stefan; Lorenz, Cristian

    2011-03-01

    Temporal subtraction techniques using 2D image registration improve the detectability of interval changes from chest radiographs. Although such methods are well known for some time they are not widely used in radiologic practice. The reason is the occurrence of strong pose differences between two acquisitions with a time interval of months to years in between. Such strong perspective differences occur in a reasonable number of cases. They cannot be compensated by available image registration methods and thus mask interval changes to be undetectable. In this paper a method is proposed to estimate a 3D pose difference by the adaptation of a 3D rib cage model to both projections. The difference between both is then compensated for, thus producing a subtraction image with virtually no change in pose. The method generally assumes that no 3D image data is available from the patient. The accuracy of pose estimation is validated with chest phantom images acquired under controlled geometric conditions. A subtle interval change simulated by a piece of plastic foam attached to the phantom becomes visible in subtraction images generated with this technique even at strong angular pose differences like an anterior-posterior inclination of 13 degrees.

  17. Wilson expansion in the minimal subtraction scheme

    International Nuclear Information System (INIS)

    Smirnov, V.A.

    1989-01-01

    The small distance expansion of the product of composite fields is constructed for an arbitrary renormalization procedure of the type of minimal subtraction scheme. Coefficient functions of the expansion are expressed explicitly through the Green functions of composite fields. The expansion has the explicity finite form: the ultraviolet (UV) divergences of the coefficient functions and composite fields are removed by the initial renormalization procedure while the infrared (IR) divergences in massless diagrams with nonvanishing contribution into the coefficient functions are removed by the R-operation which is the IR part of the R-operation. The latter is the generalization of the dimensional renormalization in the case when both UV and IR divergences are present. To derive the expansion, a ''pre-subtracting operator'' is introduced and formulas of the counter-term technique are exploited

  18. The evolution of unconditional strategies via the 'multiplier effect'.

    Science.gov (United States)

    McNamara, John M; Dall, Sasha R X

    2011-03-01

    Ostensibly, it makes sense in a changeable world to condition behaviour and development on information when it is available. Nevertheless, unconditional behavioural and life history strategies are widespread. Here, we show how intergenerational effects can limit the evolutionary value of responding to reliable environmental cues, and thus favour the evolutionary persistence of otherwise paradoxical unconditional strategies. While cue-ignoring genotypes do poorly in the wrong environments, in the right environment they will leave many copies of themselves, which will themselves leave many copies, and so on, leading genotypes to accumulate in habitats in which they do well. We call this 'The Multiplier Effect'. We explore the consequences of the multiplier effect by focussing on the ecologically important phenomenon of natal philopatry. We model the environment as a large number of temporally varying breeding sites connected by natal dispersal between sites. Our aim is to identify which aspects of an environment promote the multiplier effect. We show, if sites remain connected through some background level of 'accidental' dispersal, unconditional natal philopatry can evolve even when there is density dependence (with its accompanying kin competition effects), and cues that are only mildly erroneous. Thus, the multiplier effect may underpin the evolution and maintenance of unconditional strategies such as natal philopatry in many biological systems. © 2011 Blackwell Publishing Ltd/CNRS.

  19. Dynamic contrast-enhanced subtraction MR angiography in intracranial vascular abnormalities

    International Nuclear Information System (INIS)

    Takano, K.; Ono, H.; Utsunomiya, H.; Okazaki, M.; Tanaka, A.

    1999-01-01

    We present our clinical experience with dynamic contrast-enhanced MR angiography (MRA) with subtraction for assessing intracranial vascular abnormalities. Ten patients with various cerebrovascular disorders underwent dynamic contrast-enhanced MRA on a 1.0-T system. Thirty sections (2 mm) were acquired in 29-30 s. Maximum intensity projection images and subtracted source images were compared with those obtained by conventional angiography. In all cases, the presence or absence of abnormalities in the targeted vessels, as well as the morphology of the sagittal sinuses, was clearly visualized as in conventional angiography, without any obstructions such as hyperintense hematomas or thrombi, or intraluminal turbulence. Although the temporal and spatial resolutions with current hardware are insufficient, these preliminary results suggest that dynamic contrast-enhanced MRA with subtraction may be useful for assessing vascular lesions with hemorrhage or thrombus, and the dural sinuses. (orig.)

  20. The long-run relationship between the Japanese credit and money multipliers

    OpenAIRE

    Mototsugu Fukushige

    2013-01-01

    The standard argument is that while money creation and credit creation have different channels, they provide the same theoretical size of multipliers. However, there is usually some difference in practice. Consequently, in this paper we investigate the long-run relationship between the credit and money multipliers in Japan.

  1. The generalization of the Schur multipliers of Bieberbach groups

    Science.gov (United States)

    Masri, Rohaidah; Hassim, Hazzirah Izzati Mat; Sarmin, Nor Haniza; Ali, Nor Muhainiah Mohd; Idrus, Nor'ashiqin Mohd

    2014-12-01

    The Schur multiplier is the second homology group of a group. It has been found to be isomorphic to the kernel of a homomorphism which maps the elements in the exterior square of the group to the elements in its derived subgroup. Meanwhile, a Bieberbach group is a space group which is a discrete cocompact group of isometries of oriented Euclidean space. In this research, the Schur multipliers of Bieberbach groups with cyclic point group of order two of finite dimension are computed.

  2. A temporal subtraction method for thoracic CT images based on generalized gradient vector flow

    International Nuclear Information System (INIS)

    Miyake, Noriaki; Kim, H.; Maeda, Shinya; Itai, Yoshinori; Tan, J.K.; Ishikawa, Seiji; Katsuragawa, Shigehiko

    2010-01-01

    A temporal subtraction image, which is obtained by subtraction of a previous image from a current one, can be used for enhancing interval changes (such as formation of new lesions and changes in existing abnormalities) on medical images by removing most of the normal structures. If image registration is incorrect, not only the interval changes but also the normal structures would be appeared as some artifacts on the temporal subtraction image. In a temporal subtraction technique for 2-D X-ray image, the effectiveness is shown through a lot of clinical evaluation experiments, and practical use is advancing. Moreover, the MDCT (Multi-Detector row Computed Tomography) can easily introduced on medical field, the development of a temporal subtraction for thoracic CT Images is expected. In our study, a temporal subtraction technique for thoracic CT Images is developed. As the technique, the vector fields are described by use of GGVF (Generalized Gradient Vector Flow) from the previous and current CT images. Afterwards, VOI (Volume of Interest) are set up on the previous and current CT image pairs. The shift vectors are calculated by using nearest neighbor matching of the vector fields in these VOIs. The search kernel on previous CT image is set up from the obtained shift vector. The previous CT voxel which resemble standard the current voxel is detected by voxel value and vector of the GGVF in the kernel. And, the previous CT image is transformed to the same coordinate of standard voxel. Finally, temporal subtraction image is made by subtraction of a warping image from a current one. To verify the proposal method, the result of application to 7 cases and the effectiveness are described. (author)

  3. IS THE VALUE ADDED TAX A SUPERIOR SALES TAX IN ALL SALES TAXES?

    Directory of Open Access Journals (Sweden)

    MUSTAFA ALİ SARILI

    2013-05-01

    Full Text Available Value Added Tax (VAT is a tax imposed on the value added to a product at each stage of the production and distribution process. Value added is never taxed twice under VAT and thus cascading (tax on tax effects do not occur. It is a single tax on goods and services but the tax is collected multiple stages. At each of these stages, the amount of tax payable is computed by subtracting the tax previously paid on purchases from the tax charged on sales by the traders for each taxation period. In last three decades, VAT, a relatively new and better commodity taxation, has been introduced in many countries. It has replaced different types of sales taxes in such countries. This article attempts to evaluate VAT by comparing with other sales taxes.

  4. New design of an RSFQ parallel multiply-accumulate unit

    International Nuclear Information System (INIS)

    Kataeva, Irina; Engseth, Henrik; Kidiyarova-Shevchenko, Anna

    2006-01-01

    The multiply-accumulate unit (MAC) is a central component of a successive interference canceller, an advanced receiver for W-CDMA base stations. A 4 x 4 two's complement fixed point RSFQ MAC with rounding to 5 bits has been simulated using VHDL, and maximum performance is equal to 24 GMACS (giga-multiply-accumulates per second). The clock distribution network has been re-designed from a linear ripple to a binary tree network in order to eliminate the data dependence of the clock propagation speed and reduce the number of Josephson junctions in clock lines. The 4 x 4 bit MAC has been designed for the HYPRES 4.5 kA cm -2 process and its components have been experimentally tested at low frequency: the 5-bit combiner, using an exhaustive test pattern, had margins on DC bias voltage of ± 18%, and the 4 x 4 parallel multiplier had margins equal to ± 2%

  5. Momentum-subtraction renormalization techniques in curved space-time

    Energy Technology Data Exchange (ETDEWEB)

    Foda, O.

    1987-10-01

    Momentum-subtraction techniques, specifically BPHZ and Zimmermann's Normal Product algorithm, are introduced as useful tools in the study of quantum field theories in the presence of background fields. In a model of a self-interacting massive scalar field, conformally coupled to a general asymptotically-flat curved space-time with a trivial topology, momentum-subtractions are shown to respect invariance under general coordinate transformations. As an illustration, general expressions for the trace anomalies are derived, and checked by explicit evaluation of the purely gravitational contributions in the free field theory limit. Furthermore, the trace of the renormalized energy-momentum tensor is shown to vanish at the Gell-Mann Low eigenvalue as it should.

  6. Momentum-subtraction renormalization techniques in curved space-time

    International Nuclear Information System (INIS)

    Foda, O.

    1987-01-01

    Momentum-subtraction techniques, specifically BPHZ and Zimmermann's Normal Product algorithm, are introduced as useful tools in the study of quantum field theories in the presence of background fields. In a model of a self-interacting massive scalar field, conformally coupled to a general asymptotically-flat curved space-time with a trivial topology, momentum-subtractions are shown to respect invariance under general coordinate transformations. As an illustration, general expressions for the trace anomalies are derived, and checked by explicit evaluation of the purely gravitational contributions in the free field theory limit. Furthermore, the trace of the renormalized energy-momentum tensor is shown to vanish at the Gell-Mann Low eigenvalue as it should

  7. Subtraction with hadronic initial states at NLO: an NNLO-compatible scheme

    Science.gov (United States)

    Somogyi, Gábor

    2009-05-01

    We present an NNLO-compatible subtraction scheme for computing QCD jet cross sections of hadron-initiated processes at NLO accuracy. The scheme is constructed specifically with those complications in mind, that emerge when extending the subtraction algorithm to next-to-next-to-leading order. It is therefore possible to embed the present scheme in a full NNLO computation without any modifications.

  8. Subtraction with hadronic initial states at NLO: an NNLO-compatible scheme

    International Nuclear Information System (INIS)

    Somogyi, Gabor

    2009-01-01

    We present an NNLO-compatible subtraction scheme for computing QCD jet cross sections of hadron-initiated processes at NLO accuracy. The scheme is constructed specifically with those complications in mind, that emerge when extending the subtraction algorithm to next-to-next-to-leading order. It is therefore possible to embed the present scheme in a full NNLO computation without any modifications.

  9. Continuous-variable measurement-device-independent quantum key distribution with photon subtraction

    Science.gov (United States)

    Ma, Hong-Xin; Huang, Peng; Bai, Dong-Yun; Wang, Shi-Yu; Bao, Wan-Su; Zeng, Gui-Hua

    2018-04-01

    It has been found that non-Gaussian operations can be applied to increase and distill entanglement between Gaussian entangled states. We show the successful use of the non-Gaussian operation, in particular, photon subtraction operation, on the continuous-variable measurement-device-independent quantum key distribution (CV-MDI-QKD) protocol. The proposed method can be implemented based on existing technologies. Security analysis shows that the photon subtraction operation can remarkably increase the maximal transmission distance of the CV-MDI-QKD protocol, which precisely make up for the shortcoming of the original CV-MDI-QKD protocol, and one-photon subtraction operation has the best performance. Moreover, the proposed protocol provides a feasible method for the experimental implementation of the CV-MDI-QKD protocol.

  10. Digital subtraction radiography in the study of moving laryngeal structures

    International Nuclear Information System (INIS)

    Perri, G.; Falaschi, F.; Pieri, L.; Esposito, S.; Ursino, F.

    1988-01-01

    Digital subtraction radiography (DSR) was applied to the study of the larynx in 11 healthy subjects and 15 pathological cases. The method, consisting in the subtraction of images obtained at rest and during phonation or respiratory phases, allowed a clear definition of the normal moving structures - i.e. vocal cords, false cords, pyriform sinuses, thyroid cartilage. Moreover, several pathological conditions could be demonstrated. DSR asserts thus itself as a suitable technique in the functional evaluation of glottis

  11. SU-D-17A-02: Four-Dimensional CBCT Using Conventional CBCT Dataset and Iterative Subtraction Algorithm of a Lung Patient

    International Nuclear Information System (INIS)

    Hu, E; Lasio, G; Yi, B

    2014-01-01

    Purpose: The Iterative Subtraction Algorithm (ISA) method generates retrospectively a pre-selected motion phase cone-beam CT image from the full motion cone-beam CT acquired at standard rotation speed. This work evaluates ISA method with real lung patient data. Methods: The goal of the ISA algorithm is to extract motion and no- motion components form the full reconstruction CBCT. The workflow consists of subtracting from the full CBCT all of the undesired motion phases and obtain a motion de-blurred single-phase CBCT image, followed by iteration of this subtraction process. ISA is realized as follows: 1) The projections are sorted to various phases, and from all phases, a full reconstruction is performed to generate an image CTM. 2) Generate forward projections of CTM at the desired phase projection angles, the subtraction of projection and the forward projection will reconstruct a CTSub1, which diminishes the desired phase component. 3) By adding back the CTSub1 to CTm, no motion CBCT, CTS1, can be computed. 4) CTS1 still contains residual motion component. 5) This residual motion component can be further reduced by iteration.The ISA 4DCBCT technique was implemented using Varian Trilogy accelerator OBI system. To evaluate the method, a lung patient CBCT dataset was used. The reconstruction algorithm is FDK. Results: The single phase CBCT reconstruction generated via ISA successfully isolates the desired motion phase from the full motion CBCT, effectively reducing motion blur. It also shows improved image quality, with reduced streak artifacts with respect to the reconstructions from unprocessed phase-sorted projections only. Conclusion: A CBCT motion de-blurring algorithm, ISA, has been developed and evaluated with lung patient data. The algorithm allows improved visualization of a single phase motion extracted from a standard CBCT dataset. This study has been supported by National Institute of Health through R01CA133539

  12. A method for dynamic subtraction MR imaging of the liver

    Directory of Open Access Journals (Sweden)

    Setti Ernesto

    2006-06-01

    Full Text Available Abstract Background Subtraction of Dynamic Contrast-Enhanced 3D Magnetic Resonance (DCE-MR volumes can result in images that depict and accurately characterize a variety of liver lesions. However, the diagnostic utility of subtraction images depends on the extent of co-registration between non-enhanced and enhanced volumes. Movement of liver structures during acquisition must be corrected prior to subtraction. Currently available methods are computer intensive. We report a new method for the dynamic subtraction of MR liver images that does not require excessive computer time. Methods Nineteen consecutive patients (median age 45 years; range 37–67 were evaluated by VIBE T1-weighted sequences (TR 5.2 ms, TE 2.6 ms, flip angle 20°, slice thickness 1.5 mm acquired before and 45s after contrast injection. Acquisition parameters were optimized for best portal system enhancement. Pre and post-contrast liver volumes were realigned using our 3D registration method which combines: (a rigid 3D translation using maximization of normalized mutual information (NMI, and (b fast 2D non-rigid registration which employs a complex discrete wavelet transform algorithm to maximize pixel phase correlation and perform multiresolution analysis. Registration performance was assessed quantitatively by NMI. Results The new registration procedure was able to realign liver structures in all 19 patients. NMI increased by about 8% after rigid registration (native vs. rigid registration 0.073 ± 0.031 vs. 0.078 ± 0.031, n.s., paired t-test and by a further 23% (0.096 ± 0.035 vs. 0.078 ± 0.031, p t-test after non-rigid realignment. The overall average NMI increase was 31%. Conclusion This new method for realigning dynamic contrast-enhanced 3D MR volumes of liver leads to subtraction images that enhance diagnostic possibilities for liver lesions.

  13. Multiplying Money

    Directory of Open Access Journals (Sweden)

    Garry Jacobs

    2013-05-01

    Full Text Available This article is not a comprehensive factual history of money as an economic instrument. It aims rather to present an essential psychological history of the power of money as a social organization or social technology. It explores the catalytic role of money in the development of society and its ever-increasing capacity for accomplishment in both economic and non-economic fields. This perspective focuses attention on the unutilized potential for harnessing the social power of money for promoting full employment, global development and human welfare. The title ‘multiplying money’ is intended to convey the idea that this untapped potential is exponential in nature. In order to recognize it, some fundamental misconceptions about the nature of money, how it is created and on what it is based need to be examined. This is the second article in a series.

  14. Equations for the stochastic cumulative multiplying chain

    Energy Technology Data Exchange (ETDEWEB)

    Lewins, J D [Cambridge Univ. (UK). Dept. of Engineering

    1980-01-01

    The forward and backward equations for the conditional probability of the neutron multiplying chain are derived in a new generalization accounting for the chain length and admitting time dependent properties. These Kolmogorov equations form the basis of a variational and hence complete description of the 'lumped' multiplying system. The equations reduce to the marginal distribution, summed over all chain lengths, and to the simpler equations previously derived for that problem. The method of derivation, direct and in the probability space with the minimum of mathematical manipulations, is perhaps the chief attraction: the equations are also displayed in conventional generating function form. As such, they appear to apply to number of problems in areas of social anthropology, polymer chemistry, genetics and cell biology as well as neutron reactor theory and radiation damage.

  15. Equations for the stochastic cumulative multiplying chain

    International Nuclear Information System (INIS)

    Lewins, J.D.

    1980-01-01

    The forward and backward equations for the conditional probability of the neutron multiplying chain are derived in a new generalization accounting for the chain length and admitting time dependent properties. These Kolmogorov equations form the basis of a variational and hence complete description of the 'lumped' multiplying system. The equations reduce to the marginal distribution, summed over all chain lengths, and to the simpler equations previously derived for that problem. The method of derivation, direct and in the probability space with the minimum of mathematical manipulations, is perhaps the chief attraction: the equations are also displayed in conventional generating function form. As such, they appear to apply to number of problems in areas of social anthropology, polymer chemistry, genetics and cell biology as well as neutron reactor theory and radiation damage. (author)

  16. Enhancing shelf life of minimally processed multiplier onion using silicone membrane.

    Science.gov (United States)

    Naik, Ravindra; Ambrose, Dawn C P; Raghavan, G S Vijaya; Annamalai, S J K

    2014-12-01

    The aim of storage of minimal processed product is to increase the shelf life and thereby extend the period of availability of minimally processed produce. The silicone membrane makes use of the ability of polymer to permit selective passage of gases at different rates according to their physical and chemical properties. Here, the product stored maintains its own atmosphere by the combined effects of respiration process of the commodity and the diffusion rate through the membrane. A study was undertaken to enhance the shelf life of minimally processed multiplier onion with silicone membrane. The respiration activity was recorded at a temperature of 30 ± 2 °C (RH = 60 %) and 5 ± 1 °C (RH = 90 %). The respiration was found to be 23.4, 15.6, 10 mg CO2kg(-1)h(-1) at 5 ± 1 °C and 140, 110, 60 mg CO2kg(-1) h(-1) at 30 ± 2° for the peeled, sliced and diced multiplier onion, respectively. The respiration rate for the fresh multiplier onion was recorded to be 5, 10 mg CO2kg(-1) h(-1) at 5 ± 1 °C and 30 ± 1 ° C, respectively. Based on the shelf life studies and on the sensory evaluation, it was found that only the peeled multiplier onion could be stored. The sliced and diced multiplier onion did not have the required shelf life. The shelf life of the multiplier onion in the peel form could be increased from 4-5 days to 14 days by using the combined effect of silicone membrane (6 cm(2)/kg) and low temperature (5 ± 1 °C).

  17. Private Debt Overhang and the Government Spending Multiplier: Evidence for the United States

    OpenAIRE

    Bernardini, Marco; Peersman, Gert

    2015-01-01

    Using state-dependent local projection methods and historical U.S. data, we find that government spending multipliers are considerably larger in periods of private debt overhang. In particular, we find significant crowding-out of personal consumption and investment in low-debt states, resulting in multipliers that are significantly below one. Conversely, in periods of private debt overhang, there is a strong crowding-in effect, while multipliers are much larger than one. In high-debt states, ...

  18. Mental Computation or Standard Algorithm? Children's Strategy Choices on Multi-Digit Subtractions

    Science.gov (United States)

    Torbeyns, Joke; Verschaffel, Lieven

    2016-01-01

    This study analyzed children's use of mental computation strategies and the standard algorithm on multi-digit subtractions. Fifty-eight Flemish 4th graders of varying mathematical achievement level were individually offered subtractions that either stimulated the use of mental computation strategies or the standard algorithm in one choice and two…

  19. Removal of arterial wall calcifications in CT angiography by local subtraction

    International Nuclear Information System (INIS)

    Straten, Marcel van; Venema, Henk W.; Streekstra, Geert J.; Reekers, Jim A.; Heeten, Gerard J. den; Grimbergen, Cornelis A.

    2003-01-01

    CT Angiography (CTA) is an established technique for the minimally invasive imaging of arteries. The technique of maximum intensity projection (MIP) is often used to get a comprehensive overview of the vascular anatomy. On a MIP, however, arterial wall calcifications may hinder the visualization of the arterial lumen. These calcifications are in direct contact with the contrast-enhanced blood, which makes removal difficult. We present a local subtraction method for the automatic removal of these calcifications. In our approach a second CT scan has to be made, prior to contrast injection. The calcifications in both scans are registered prior to subtraction to compensate for displacements in between the two scans. Local subtraction results are compared with results obtained by thresholding. The method was tested in a phantom and with data from four patients. The phantom represented an artery with different types of stenosis. Data were used from patients for which CTA of the renal arteries was performed. For two patients the electrocardiogram (ECG) was recorded during the CTA examination, making retrospective cardiac gated reconstructions possible. Both the phantom and the patient study showed that the local subtraction method is capable of removing calcifications and visualizing the residual lumen. In the patient study it appeared that some artifacts remained for higher pitch values. We conclude that the local subtraction method is less subjective and more accurate than thresholding. Best results are obtained by use of a small pitch, at the expense of the volume covered during a single breath hold

  20. Nonenhanced magnetic resonance angiography (MRA) of the calf arteries at 3 Tesla: intraindividual comparison of 3D flow-dependent subtractive MRA and 2D flow-independent non-subtractive MRA

    Energy Technology Data Exchange (ETDEWEB)

    Knobloch, Gesine; Lauff, Marie-Teres; Hirsch, Sebastian; Hamm, Bernd; Wagner, Moritz [Charite - Universitaetsmedizin Berlin, Department of Radiology, Berlin (Germany); Schwenke, Carsten [SCO:SSiS Statistical Consulting, Berlin (Germany)

    2016-12-15

    To prospectively compare 3D flow-dependent subtractive MRA vs. 2D flow-independent non-subtractive MRA for assessment of the calf arteries at 3 Tesla. Forty-two patients with peripheral arterial occlusive disease underwent nonenhanced MRA of calf arteries at 3 Tesla with 3D flow-dependent subtractive MRA (fast spin echo sequence; 3D-FSE-MRA) and 2D flow-independent non-subtractive MRA (balanced steady-state-free-precession sequence; 2D-bSSFP-MRA). Moreover, all patients underwent contrast-enhanced MRA (CE-MRA) as standard-of-reference. Two readers performed a per-segment evaluation for image quality (4 = excellent to 0 = non-diagnostic) and severity of stenosis. Image quality scores of 2D-bSSFP-MRA were significantly higher compared to 3D-FSE-MRA (medians across readers: 4 vs. 3; p < 0.0001) with lower rates of non-diagnostic vessel segments on 2D-bSSFP-MRA (reader 1: <1 % vs. 15 %; reader 2: 1 % vs. 29 %; p < 0.05). Diagnostic performance of 2D-bSSFP-MRA and 3D-FSE-MRA across readers showed sensitivities of 89 % (214/240) vs. 70 % (168/240), p = 0.0153; specificities: 91 % (840/926) vs. 63 % (585/926), p < 0.0001; and diagnostic accuracies of 90 % (1054/1166) vs. 65 % (753/1166), p < 0.0001. 2D flow-independent non-subtractive MRA (2D-bSSFP-MRA) is a robust nonenhanced MRA technique for assessment of the calf arteries at 3 Tesla with significantly higher image quality and diagnostic accuracy compared to 3D flow-dependent subtractive MRA (3D-FSE-MRA). (orig.)

  1. Digital subtraction angiography of carotid bifurcation

    International Nuclear Information System (INIS)

    Vries, A.R. de.

    1984-01-01

    This study demonstrates the reliability of digital subtraction angiography (DSA) by means of intra- and interobserver investigations as well as indicating the possibility of substituting catheterangiography by DSA in the diagnosis of carotid bifurcation. Whenever insufficient information is obtained from the combination of non-invasive investigation and DSA, a catheterangiogram will be necessary. (Auth.)

  2. Digital subtraction angiography: myths and reality

    International Nuclear Information System (INIS)

    Levin, D.C.

    1984-01-01

    Some of the claims made about digital subtraction angiography (DSA) when it was first developed have turned out to be greatly exaggerated, and some members of the radiologic community have become disillusioned with its capabilities. The author discusses some of the limitations of DSA, and concludes that the advantages of DSA outweigh its limitations

  3. On centralized power pool auction: a novel multipliers stabilization procedure

    International Nuclear Information System (INIS)

    Jimenez-Redondo, Noemi

    2005-01-01

    This paper addresses the Short-Term Hydro-Thermal Coordination (STHTC) problem. It is a large-scale, combinatorial and nonlinear optimization problem. It is usually solved using a Lagrangian Relaxation (LR) approach. LR procedure is based on the solution of the dual problem of the original one. The dual problem variables are the Lagrange multipliers. These multipliers have an economic meaning: electric energy hourly prices. This paper focuses on an efficient solution of the dual problem of the STHTC problem. A novel multiplier stabilization technique, which significantly improves the quality of the solution, is presented. The provided method could be the optimization tool used by the Independent System Operator of a centralized Power Pool. The solution procedure diminishes the conflict of interest in determining energy prices. A realistic large-scale case study illustrates the behavior of the presented approach. (Author)

  4. Study on neutron irradiation behavior of beryllium as neutron multiplier

    Energy Technology Data Exchange (ETDEWEB)

    Ishitsuka, Etsuo [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment

    1998-03-01

    More than 300 tons beryllium is expected to be used as a neutron multiplier in ITER, and study on the neutron irradiation behavior of beryllium as the neutron multiplier with Japan Materials Testing Reactor (JMTR) were performed to get the engineering data for fusion blanket design. This study started as the study on the tritium behavior in beryllium neutron reflector in order to make clear the generation mechanism on tritium of JMTR primary coolant since 1985. These experiences were handed over to beryllium studies for fusion study, and overall studies such as production technology of beryllium pebbles, irradiation behavior evaluation and reprocessing technology have been started since 1990. In this presentation, study on the neutron irradiation behavior of beryllium as the neutron multiplier with JMTR was reviewed from the point of tritium release, thermal properties, mechanical properties and reprocessing technology. (author)

  5. The contribution of chemical shift imaging with digital subtracting images to the diagnosis of steatohepatitis

    International Nuclear Information System (INIS)

    Guo Xinghua; Wang Juanping; Zhang Chongjie; Zheng Guofang; Fan Ruiqiang; Zhu Sumei; Liu Qiwang

    2006-01-01

    Objective: To investigate the diagnosis value of chemical shift imaging with digital subtracting in steatohepatitis. Methods: The in-phase images were subtracted by the out-phase ones in 34 cases of steatohepatitis, and the CNR were measured on these subtracted images to estimate the steatosis of the liver. The relationship of CT grade of steatohepatitis and CNR from the subtracted images was analyzed to evaluate the relationship between CNR and the degree of hepatic steatosis. The sensitivity and specificity of the subtracting and eyeballing methods were compared with chi-square test. Results: On the subtracted images, the liver and spleen were seen nearly the same aspects as low signals, CNR=0.98±0.06, meanwhile the spongy vertebra and the subcutaneous or abdominal lipid were seen as obvious higher signals in 52 normal cases. On the 34 steatohepatitis, scattered high signals were seen in the liver, which made the signal of liver higher than that of spleen, CNR=3.25±0.91--14.35±6.10. There was positive correlation between CNR and CT grade in the 34 cases of steatohepatitis, r=0.893, P<0.01. The sensitivity and specificity of the subtracting method were 88.24% and 94. 23%, significantly higher than that of the eyeballing results, 32.35% and 80.77%, P<0.01 and P<0.05. Conclusion: Chemical shift imaging with digital subtracting is a sensitive, specific, objective method to diagnose steatohepatitis and it is of potential ability for quantitative diagnosis. (authors)

  6. Evaluation of the minimum iodine concentration for contrast-enhanced subtraction mammography

    International Nuclear Information System (INIS)

    Baldelli, P; Bravin, A; Maggio, C Di; Gennaro, G; Sarnelli, A; Taibi, A; Gambaccini, M

    2006-01-01

    Early manifestation of breast cancer is often very subtle and is displayed in a complex and variable pattern of normal anatomy that may obscure the disease. The use of dual-energy techniques, that can remove the structural noise, and contrast media, that enhance the region surrounding the tumour, could help us to improve the detectability of the lesions. The aim of this work is to investigate the use of an iodine-based contrast medium in mammography with two different double exposure techniques: K-edge subtraction mammography and temporal subtraction mammography. Both techniques have been investigated by using an ideal source, like monochromatic beams produced at a synchrotron radiation facility and a clinical digital mammography system. A dedicated three-component phantom containing cavities filled with different iodine concentrations has been developed and used for measurements. For each technique, information about the minimum iodine concentration, which provides a significant enhancement of the detectability of the pathology by minimizing the risk due to high dose and high concentration of contrast medium, has been obtained. In particular, for cavities of 5 and 8 mm in diameter filled with iodine solutions, the minimum concentration needed to obtain a contrast-to-noise ratio of 5 with a mean glandular dose of 2 mGy has been calculated. The minimum concentrations estimated with monochromatic beams and K-edge subtraction mammography are 0.9 mg ml -1 and 1.34 mg ml -1 for the biggest and smallest details, respectively, while for temporal subtraction mammography they are 0.84 mg ml -1 and 1.31 mg ml -1 . With the conventional clinical system the minimum concentrations for the K-edge subtraction mammography are 4.13 mg ml -1 (8 mm diameter) and 5.75 mg ml -1 (5 mm diameter), while for the temporal subtraction mammography they are 1.01 mg ml -1 (8 mm diameter) and 1.57 mg ml -1 (5 mm diameter)

  7. KAJIAN EFEK MULTIPLIER PRODUK UNGGULAN BERBASIS KLUSTER UKM PENGOLAHAN IKAN ASAP

    Directory of Open Access Journals (Sweden)

    Yusmar Ardhi Hidayat

    2015-05-01

    Full Text Available The purpose of this research are to analyze scale of production of leading commodities and multiplier effect of cultivation and smoked fish in Wonosari, Bonang Demak. This research applies census method in collecting data from all business unit which identified as leading commodities in Wirosari Village, Bonang, Demak Regency. Regarding survey conducted, there are 18 catfish breeders and 49 smoked fish small business used as respondent. Primary data used in this research are rate of production in basis goods, land area, capital, raw materials, manpower, and income multiplier. To support empirical discussion, tools of analysis used in this research are descriptive statistics and income multiplier. Results of this research are primary commodities in Wonosari Village are smoked fish and fresh cat fish. Total production of smoked fish reaches 6.4 Ton each day for with type of smoked fish such as river cat fish, tongkol, sting-ray, cat fish, and other river fish. Meanwhile total production of catfish breeding reaches 105 Ton in first harvest after 2-3 months. Based on that number, smoked fish business promise higher profit than profits catfish breeding. Tujuan penelitian ini adalah menganalisis tingkat produksi dan efek multiplier produk unggulan budidaya dan pengasapan ikan di Desa Wonosari, Bonang Kabupaten Demak. Penelitian mengunakan metode sensus dengan mencari data dari semua unit usaha yang merupakan produk unggulan di Desa Wirosari, Bonang Kecamatan Demak. Responden yang diperoleh sejumlah 18 pembudidaya ikan dan 49 usaha pengasapan ikan. Data primer yang akan digunakan yaitu data jumlah produksi komoditas unggulan, luas lahan, jumlah modal, bahan baku, tenaga kerja, dan multiplier pendapatan. Alat analisis yang digunakan dalam penelitian ini adalah statistik deskriptif, dan indeks multiplier pendapatan. Hasil penelitian menunjukkan bahwa komoditas unggulan Desa Wonosari Kecamatan Bonang Kabupaten Demak adalah Ikan Asap dan Budidaya Ikan Lele

  8. Multiply excited molecules produced by photon and electron interactions

    International Nuclear Information System (INIS)

    Odagiri, T.; Kouchi, N.

    2006-01-01

    The photon and electron interactions with molecules resulting in the formation of multiply excited molecules and the subsequent decay are subjects of great interest because the independent electron model and Born-Oppenheimer approximation are much less reliable for the multiply excited states of molecules than for the ground and lower excited electronic states. We have three methods to observe and investigate multiply excited molecules: 1) Measurements of the cross sections for the emission of fluorescence emitted by neutral fragments in the photoexcitation of molecules as a function of incident photon energy [1-3], 2) Measurements of the electron energy-loss spectra tagged with the fluorescence photons emitted by neutral fragments [4], 3) Measurements of the cross sections for generating a pair of photons in absorption of a single photon by a molecule as a function of incident photon energy [5-7]. Multiply excited states degenerate with ionization continua, which make a large contribution in the cross section curve involving ionization processes. The key point of our methods is hence that we measure cross sections free from ionization. The feature of multiply excited states is noticeable in such a cross section curve. Recently we have measured: i) the cross sections for the emission of the Lyman- fluorescence in the photoexcitation of CH 4 as a function of incident photon energy in the range 18-51 eV, ii) the electron energy-loss spectrum of CH 4 tagged with the Lyman-photons at 80 eV incident electron energy and 10 electron scattering angle in the range of the energy loss 20-45 eV, in order to understand the formation and decay of the doubly excited methane in photon and electron interactions. [8] The results are summarized in this paper and the simultaneous excitation of two electrons by electron interaction is compared with that by photon interaction in terms of the oscillator strength. (authors)

  9. Isometric multipliers of a vector valued Beurling algebra on a ...

    Indian Academy of Sciences (India)

    Throughout, let S be a nonunital faith- ful abelian semigroup, and let A be a commutative Banach algebra. A map σ : S → S is a multiplier [1, 4] if σ(xy) = xσ(y) = σ(x)y, x,y ∈ S. Let M(S) be the set of all multipliers of S. Then M(S) is a unital abelian semigroup under composition. Since S is faithful, S can be imbedded as an ...

  10. [The backgroud sky subtraction around [OIII] line in LAMOST QSO spectra].

    Science.gov (United States)

    Shi, Zhi-Xin; Comte, Georges; Luo, A-Li; Tu, Liang-Ping; Zhao, Yong-Heng; Wu, Fu-Chao

    2014-11-01

    At present, most sky-subtraction methods focus on the full spectrum, not the particular location, especially for the backgroud sky around [OIII] line which is very important to low redshift quasars. A new method to precisely subtract sky lines in local region is proposed in the present paper, which sloves the problem that the width of Hβ-[OIII] line is effected by the backgroud sky subtraction. The exprimental results show that, for different redshift quasars, the spectral quality has been significantly improved using our method relative to the original batch program by LAMOST. It provides a complementary solution for the small part of LAMOST spectra which are not well handled by LAMOST 2D pipeline. Meanwhile, This method has been used in searching for candidates of double-peaked Active Galactic Nuclei.

  11. A study of transverse image reconstruction with digital subtraction angiography

    International Nuclear Information System (INIS)

    Sakamoto, Kiyoshi; Kotoura, Noriko; Terasawa, Yuuji; Oda, Masahiko; Gotou, Hiroshi; Nasada, Toshiya; Tanooka, Masao

    1995-01-01

    For digital subtraction angiography (DSA) with C-type equipment, it is possible to radiate an X-ray during rotation and to collect data at different angular settings. We tried to reconstruct transverse image from data obtained by scanning DSA images at different angular settings. 88 projection data were obtained by rotating the object at 180deg during radiation. Reconstruction was made using the convolution method with pixel value distribution for each projection. Similarly, the image quality of the reconstructed images were compared with the unsubtracted and subtracted ones. In case a part object was outside the calculating region, artifacts were generally produced. However, the artifacts were reduced by subtracting the background from the image. In addition, the cupping phenomenon caused by beam hardening was relaxed and high-quality imaging could be achieved. This method will become even more effective, if we will use it with selective angiography in which the limited area is enhanced. (author)

  12. Low‐Power and Low‐Hardware Bit‐Parallel Polynomial Basis Systolic Multiplier over GF(2m for Irreducible Polynomials

    Directory of Open Access Journals (Sweden)

    Sudha Ellison Mathe

    2017-08-01

    Full Text Available Multiplication in finite fields is used in many applications, especially in cryptography. It is a basic and the most computationally intensive operation from among all such operations. Several systolic multipliers are proposed in the literature that offer low hardware complexity or high speed. In this paper, a bit‐parallel polynomial basis systolic multiplier for generic irreducible polynomials is proposed based on a modified interleaved multiplication method. The hardware complexity and delay of the proposed multiplier are estimated, and a comparison with the corresponding multipliers available in the literature is presented. Of the corresponding multipliers, the proposed multiplier achieves a reduction in the hardware complexity of up to 20% when compared to the best multiplier for m = 163. The synthesis results of application‐specific integrated circuit and field‐programmable gate array implementations of the proposed multiplier are also presented. From the synthesis results, it is inferred that the proposed multiplier achieves low power consumption and low area complexitywhen compared to the best of the corresponding multipliers.

  13. Subtracting and Fitting Histograms using Profile Likelihood

    CERN Document Server

    D'Almeida, F M L

    2008-01-01

    It is known that many interesting signals expected at LHC are of unknown shape and strongly contaminated by background events. These signals will be dif cult to detect during the rst years of LHC operation due to the initial low luminosity. In this work, one presents a method of subtracting histograms based on the pro le likelihood function when the background is previously estimated by Monte Carlo events and one has low statistics. Estimators for the signal in each bin of the histogram difference are calculated so as limits for the signals with 68.3% of Con dence Level in a low statistics case when one has a exponential background and a Gaussian signal. The method can also be used to t histograms when the signal shape is known. Our results show a good performance and avoid the problem of negative values when subtracting histograms.

  14. Californium Multiplier. Part I. Design for neutron radiography

    International Nuclear Information System (INIS)

    Crosbie, K.L.; Preskitt, C.A.; John, J.; Hastings, J.D.

    1982-01-01

    The Californium Multiplier (CFX) is a subcritical assembly of enriched uranium surrounding a californium-252 neutron source. The function of the CFX is to multiply the neutrons emitted by the source to a number sufficient for neutron radiography. The CFX is designed to provide a collimated beam of thermal neutrons from which the gamma radiation is filtered, and the scattered neutrons are reduced to make it suitable for high resolution radiography. The entire system has inherent safety features, which provide for system and personnel safety, and it operates at moderate cost. In Part I, the CFX and the theory of its operation are described in detail. Part II covers the performance of the Mound Facility CFX

  15. Comparative study between rib imaging of DR dual energy subtraction technology and chest imaging

    International Nuclear Information System (INIS)

    Yu Jianming; Lei Ziqiao; Kong Xiangchuang

    2006-01-01

    Objective: To investigate the application value of DR dual energy subtraction technology in rib lesions. Methods: 200 patients were performed with chest DR dual energy subtraction, comparing the rib imaging between DR of thorax and chest imaging using ROC analysis. Results: Among the total of 200 patients, there are 50 cases of rib calcification, 7 cases of rib destruction, 22 cases of rib fracture. The calcification, destruction and fracture were displayed respectively by ribs below diaphragm and rib markings. The analytic parameter of rib imaging of DR dual energy subtraction Az is 0.9367, while that of rib imaging of chest Az is 0.6830. Conclusion: DR dual energy subtraction technology is superior to chest imaging in the displaying of rib lesion and ribs below diaphragm. (authors)

  16. Subtraction of random coincidences in γ-ray spectroscopy: A new approach

    International Nuclear Information System (INIS)

    Pattabiraman, N.S.; Ghugre, S.S.; Basu, S.K.; Garg, U.; Ray, S.; Sinha, A.K.; Zhu, S.

    2006-01-01

    A new analytical method for estimation and subsequent subtraction of random coincidences has been developed. It utilizes the knowledge of the counts in the main diagonal of a background-subtracted symmetric data set for the estimation of the events originating from random coincidences. This procedure has been successfully applied to several data sets. It could be a valuable tool for low-fold data sets, especially for low-cross-section events

  17. Area efficient radix 4/sup 2/ 64 point pipeline fft architecture using modified csd multiplier

    International Nuclear Information System (INIS)

    Siddiq, F.; Muhammad, T.; Iqbal, M.

    2014-01-01

    A modified Fast Fourier Transform (FFT) based radix 42 algorithm for Orthogonal Frequency Division Multiplexing (OFDM) systems is presented. When compared with similar schemes like Canonic signed digit (CSD) Constant Multiplier, the modified CSD multiplier can provide a improvement of more than 36% in terms of multiplicative complexity. In Comparison of area being occupied the amount of Full adders is reduced by 32% and amount of half adders is reduced by 42%. The modified CSD multiplier scheme is implemented on Xilinx ISE 10.1 using Spartan-III XC3S1000 FPGA as a target device. The synthesis results of modified CSD Multiplier on Xilinx show efficient Twiddle Factor ROM Design and effective area reduction in comparison to CSD constant multiplier. (author)

  18. Quantitative analysis of planar technetium-99m-sestamibi myocardial perfusion images using modified background subtraction

    International Nuclear Information System (INIS)

    Koster, K.; Wackers, F.J.; Mattera, J.A.; Fetterman, R.C.

    1990-01-01

    Standard interpolative background subtraction, as used for thallium-201 ( 201 Tl), may create artifacts when applied to planar technetium-99m-Sestamibi ( 99m Tc-Sestamibi) images, apparently because of the oversubtraction of relatively high extra-cardiac activity. A modified background subtraction algorithm was developed and compared to standard background subtraction in 16 patients who had both exercise-delayed 201 Tl and exercise-rest 99m Tc-Sestamibi imaging. Furthermore, a new normal data base was generated. Normal 99m Tc-Sestamibi distribution was slightly different compared to 201 Tl. Using standard background subtraction, mean defect reversibility was significantly underestimated by 99m Tc-Sestamibi compared to 201 Tl (2.8 +/- 4.9 versus -1.8 +/- 8.4, p less than 0.05). Using the modified background subtraction, mean defect reversibility on 201 Tl and 99m Tc-Sestamibi images was comparable (2.8 +/- 4.9 versus 1.7 +/- 5.2, p = NS). We conclude, that for quantification of 99m Tc-Sestamibi images a new normal data base, as well as a modification of the interpolative background subtraction method should be employed to obtain quantitative results comparable to those with 201 Tl

  19. The digital subtraction technique in lateral urethrocystography. Die laterale Urethrozystographie in digitaler Subtraktionstechnik

    Energy Technology Data Exchange (ETDEWEB)

    Wolf, K. (Radiologische Abt., Caritas-Krankenhaus, Bad Mergentheim (Germany)); Peterseim, H. (Frauenklinik, Caritas-Krankenhaus, Bad Mergentheim (Germany)); Grehn, S. (Radiologische Abt., Caritas-Krankenhaus, Bad Mergentheim (Germany))

    1994-09-01

    The first application of the digital subtraction technique to lateral urethrocystography is described. This methodology facilitates gynecological-urological operations by providing reliable investigation results and an unambiguous image interpretation. Methods and first experiences with the digital subtraction technique in gynecological-urological diagnosis are reported. (orig.)

  20. Spectral Subtraction Approach for Interference Reduction of MIMO Channel Wireless Systems

    Directory of Open Access Journals (Sweden)

    Tomohiro Ono

    2005-08-01

    Full Text Available In this paper, a generalized spectral subtraction approach for reducing additive impulsive noise, narrowband signals, white Gaussian noise and DS-CDMA interferences in MIMO channel DS-CDMA wireless communication systems is investigated. The interference noise reduction or suppression is essential problem in wireless mobile communication systems to improve the quality of communication. The spectrum subtraction scheme is applied to the interference noise reduction problems for noisy MIMO channel systems. The interferences in space and time domain signals can effectively be suppressed by selecting threshold values, and the computational load with the FFT is not large. Further, the fading effects of channel are compensated by spectral modification with the spectral subtraction process. In the simulations, the effectiveness of the proposed methods for the MIMO channel DS-CDMA is shown to compare with the conventional MIMO channel DS-CDMA.

  1. Time efficient signed Vedic multiplier using redundant binary representation

    Directory of Open Access Journals (Sweden)

    Ranjan Kumar Barik

    2017-03-01

    Full Text Available This study presents a high-speed signed Vedic multiplier (SVM architecture using redundant binary (RB representation in Urdhva Tiryagbhyam (UT sutra. This is the first ever effort towards extension of Vedic algorithms to the signed numbers. The proposed multiplier architecture solves the carry propagation issue in UT sutra, as carry free addition is possible in RB representation. The proposed design is coded in VHDL and synthesised in Xilinx ISE 14.4 of various FPGA devices. The proposed SVM architecture has better speed performances as compared with various state-of-the-art conventional as well as Vedic architectures.

  2. Radial multipliers on amalgamated free products of II-factors

    DEFF Research Database (Denmark)

    Möller, Sören

    2014-01-01

    Let ℳi be a family of II1-factors, containing a common II1-subfactor 풩, such that [ℳi : 풩] ∈ ℕ0 for all i. Furthermore, let ϕ: ℕ0 → ℂ. We show that if a Hankel matrix related to ϕ is trace-class, then there exists a unique completely bounded map Mϕ on the amalgamated free product of the ℳi...... with amalgamation over 풩, which acts as a radial multiplier. Hereby, we extend a result of Haagerup and the author for radial multipliers on reduced free products of unital C*- and von Neumann algebras....

  3. [Construction of forward and reverse subtracted cDNA libraries between muscle tissue of Meishan and Landrace pigs].

    Science.gov (United States)

    Xu, De-Quan; Zhang, Yi-Bing; Xiong, Yuan-Zhu; Gui, Jian-Fang; Jiang, Si-Wen; Su, Yu-Hong

    2003-07-01

    Using suppression subtractive hybridization (SSH) technique, forward and reverse subtracted cDNA libraries were constructed between Longissimus muscles from Meishan and Landrace pigs. A housekeeping gene, G3PDH, was used to estimate the efficiency of subtractive cDNA. In two cDNA libraries, G3PDH was subtracted very efficiently at appropriate 2(10) and 2(5) folds, respectively, indicating that some differentially expressed genes were also enriched at the same folds and the two subtractive cDNA libraries were very successful. A total of 709 and 673 positive clones were isolated from forward and reverse subtracted cDNA libraries, respectively. Analysis of PCR showed that most of all plasmids in the clones contained 150-750 bp inserts. The construction of subtractive cDNA libraries between muscle tissue from different pig breeds laid solid foundations for isolating and identifying the genes determining muscle growth and meat quality, which will be important to understand the mechanism of muscle growth, determination of meat quality and practice of molecular breeding.

  4. Intraarterial digital subtraction angiography

    International Nuclear Information System (INIS)

    Davis, P.C.

    1987-01-01

    Digital subtraction angiography (DSA) refers to a radiographic technique of amplifying low levels of contrast from intravascular iodine into an acceptable image of vascular anatomy. Initial enthusiasm suggested that DSA using intravenous injections (IV-DSA) would eliminate most conventional film-screen angiographic studies. It was soon apparent, however, that IV-DSA examinations were often compromised in those patients who most needed a less invasive study. Indeed, only a 70 to 85 percent accuracy rate was achieved with IV-DSA, primarily due to motion artifact, poor cardiac output, overlap of pertinent vessels, and inability to resolve smaller vessels

  5. On a gauge invariant subtraction scheme for massive quantum electrodynamics

    International Nuclear Information System (INIS)

    Abdalla, E.; Gomes, M.; Koeberle, R.

    A momentum-space subtraction scheme for massive quantum electrodynamics is proposed which respects gauge invariance, in contrast to ordinary normal product techniques. As a consequence the dependence of Green functions on the ghost mass becomes very simple and formally gauge invariant normal products of degree up to four, when subtracted according to the proposed scheme, are automatically gauge invariant. As an aplication we discuss the proof of the Adler-Bardeen theorem. Zero mass limits can be taken for Green function after the integration over intermediate states has been carried out [pt

  6. Digital subtraction arthrography of the hips and of the shoulders

    International Nuclear Information System (INIS)

    Fink, B.K.; Schedel, J.; Fink, U.; Hansen, M.; Hilbertz, T.; Hagena, F.W.

    1991-01-01

    In a study on 60 patients, it could be shown that very good results can be achieved in the region of the shoulder joint with the use of the digital subtraction technique and of digital image intensifier radiography. A further possibility of using the digital subtraction technique for proving endoprosthesis loosenings of the hip demonstrated its importance after a short time and has become a routine method in the meantime. These two examination techniques are displayed methodologically and their clinical possibilities of use are assessed in this contribution. (orig.)

  7. Radionuclide identification using subtractive clustering method

    International Nuclear Information System (INIS)

    Farias, Marcos Santana; Mourelle, Luiza de Macedo

    2011-01-01

    Radionuclide identification is crucial to planning protective measures in emergency situations. This paper presents the application of a method for a classification system of radioactive elements with a fast and efficient response. To achieve this goal is proposed the application of subtractive clustering algorithm. The proposed application can be implemented in reconfigurable hardware, a flexible medium to implement digital hardware circuits. (author)

  8. Subtraction imaging of the ECG gated cardiac CT

    Energy Technology Data Exchange (ETDEWEB)

    Tanegashima, K.; Fukui, M.; Hyodo, H.

    1987-05-01

    The subtracting manipulation of contrast-enhanced gated cardiac CT (GCCT) images was experimentally studied with TCT 60A - 30 type (Toshiba) for clinical use, thereby reducing the amount of contrast medium (CM). Initially the optimum relationship between the concentration of CM and its injected velocity was determined using the model of resected canine hearts and in actual dogs. The emphasized good-subtracted images were obtained when the difference of CT values was approximately 40 H.U. between cardiac cavity and myocardium. Such condition was feasible in the use of 25 % Diatrizoic acid and its injected velocity of 0.02 ml/kg/sec. Finally the reduction of the amount of CM by 1/3 became possible in clinical settings. The method is applicable to multi-slice GCCT in various heart diseases.

  9. Determination of stress multipliers for thin perforated plates with square array of holes

    International Nuclear Information System (INIS)

    Bhattacharya, A.; Murli, B.; Kushwaha, H.S.

    1991-01-01

    The peak stress multipliers are required to determine the maximum stresses in perforated plates for the realistic evaluation of their fatigue life. The Section III of ASME Boiler and Pressure Vessels Code does not provide any information about such multipliers to be used in thin perforated plates with square penetration pattern. Although such multipliers for membrane loadings are available in literature, they were obtained either by classical analysis or by photoelastic experiments and there is no significant finite element analysis in this area. Also it has been a common practice among designers to apply the same multipliers for loads producing bending type of stress. The stress multipliers in bending are lower than those in membrane. Therefore a reduction of resultant peak stress occurs if proper stress multipliers are used for bending. The present paper is aimed at developing a finite element technique which can be used for determining the peak stress multipliers in thin plates for membrane as well as bending loads. A quarter symmetric part of a 3 x 3 square array was chosen for the analysis. The results were obtained by computer programs PAFEC and COSMOS/M using 2-D plane stress elements for the membrane and degenerated 3-D shell element for the bending part. The results for the membrane are compared with Bailey, Hicks and Hulbert and with Meijers' finite element results for the bending part. A study was made at the initial stage by analysing a 6 x 6 square array to see the effect of holes beyond one pitch, which were left out by the 3 x 3 array and the effect of additional holes was found to be negligible. Therefore it was decided to carry out further analysis with 3 x 3 square array. Photoelastic experiments were also performed to validate the results obtained by theoretical analysis. (author)

  10. Preliminary study of lateral cerebral angiography with reverse rotation in the digital image registration and subtraction

    International Nuclear Information System (INIS)

    Shen Zhenglin; Liu Dongyang; Shen Zhenghai; Li Shuping; Zhang Ziyan; Wu Yongjuan; Liu Peijun

    2012-01-01

    Objective: Investigate the value and feasibility of image registration with reverse rotation in lateral cerebral DSA. Methods: (1) Experimental study: the target images were subtracted directly, and subtracted again after reverse rotation. Software of registration and subtraction with reverse rotation edited by the author utilizing Visual Basic. The function of the automatic angle detection by the software were evaluated to see whether it detected the angle of line. The subtraction function of DSA by the software was evaluated. (2) Clinical retrospective study: the untreated mask and target images of 15 patients with motion along vertical axis during lateral cerebral DSA were uploaded to the software. The target images were processed with and without the software to get two sets of images. (3) Evaluation: four experienced radiologists read and compared the two sets of the images,and graded their findings. Results: (1) The automatic detection by the software suggested that the target images should be rotated counterclockwise 1.3°. The subtraction result of the software was satisfactory. (2) In the 15 sets of images, there were only three sets of images deemed optimal after traditional subtraction. After reverse rotation, artifacts were significantly reduced and the image sharper. There were ten cases with significant artifacts after traditional subtraction, and those images were sharper and showed more peripheral vessels after reverse rotation. The traditional subtraction images of two sets could not be interpreted,the reverse rotation registration images reached the diagnostic quality. (3) Subjective evaluation: there were more information and less noise and distortion in the registration images with reverse rotation than in the traditional subtraction. But the image resolution decreased slightly after reverse rotation registration. Conclusion: The registration of digital angiography with reverse rotation can improve the image quality in lateral cerebral DSA

  11. A comparative study of additive and subtractive manufacturing for dental restorations.

    Science.gov (United States)

    Bae, Eun-Jeong; Jeong, Il-Do; Kim, Woong-Chul; Kim, Ji-Hwan

    2017-08-01

    Digital systems have recently found widespread application in the fabrication of dental restorations. For the clinical assessment of dental restorations fabricated digitally, it is necessary to evaluate their accuracy. However, studies of the accuracy of inlay restorations fabricated with additive manufacturing are lacking. The purpose of this in vitro study was to evaluate and compare the accuracy of inlay restorations fabricated by using recently introduced additive manufacturing with the accuracy of subtractive methods. The inlay (distal occlusal cavity) shape was fabricated using 3-dimensional image (reference data) software. Specimens were fabricated using 4 different methods (each n=10, total N=40), including 2 additive manufacturing methods, stereolithography apparatus and selective laser sintering; and 2 subtractive methods, wax and zirconia milling. Fabricated specimens were scanned using a dental scanner and then compared by overlapping reference data. The results were statistically analyzed using a 1-way analysis of variance (α=.05). Additionally, the surface morphology of 1 randomly (the first of each specimen) selected specimen from each group was evaluated using a digital microscope. The results of the overlap analysis of the dental restorations indicated that the root mean square (RMS) deviation observed in the restorations fabricated using the additive manufacturing methods were significantly different from those fabricated using the subtractive methods (Padditive manufacturing methods (P=.466). Similarly, no significant differences were found between wax and zirconia, the subtractive methods (P=.986). The observed RMS values were 106 μm for stereolithography apparatus, 113 μm for selective laser sintering, 116 μm for wax, and 119 μm for zirconia. Microscopic evaluation of the surface revealed a fine linear gap between the layers of restorations fabricated using stereolithography apparatus and a grooved hole with inconsistent weak scratches

  12. Investigation of the Decelerating Field of an Electron Multiplier under Negative Ion Impact

    DEFF Research Database (Denmark)

    Larsen, Elfinn; Kjeldgaard, K.

    1973-01-01

    The effect of the decelerating field of an electron multiplier towards negative ions was investigated under standard mass spectrometric conditions. Diminishing of this decelerating field by changing of the potential of the electron multiplier increased the overall sensitivity to negative ions...

  13. Subtractions in the Adler sum rule and violation of charge symmetry

    International Nuclear Information System (INIS)

    Dominguez, C.A.; Moreno, H.; Zepeda, A.

    1976-01-01

    The consequences of a once-subtracted dispersion relation in the derivation of the Adler sum rule are investigated. It is shown that one can expect a breakdown of charge symmetry, of the isotriplet-current hypothesis, and of scaling of the structure functions. These breakdowns are related to the possible presence of a nonzero subtraction function at asymptotic energies and arbitrary q 2 . We also comment about second-class currents and PCAC (partial conservation of axial-vector current) relations

  14. [Construction of fetal mesenchymal stem cell cDNA subtractive library].

    Science.gov (United States)

    Yang, Li; Wang, Dong-Mei; Li, Liang; Bai, Ci-Xian; Cao, Hua; Li, Ting-Yu; Pei, Xue-Tao

    2002-04-01

    To identify differentially expressed genes between fetal mesenchymal stem cell (MSC) and adult MSC, especially specified genes expressed in fetal MSC, a cDNA subtractive library of fetal MSC was constructed using suppression subtractive hybridization (SSH) technique. At first, total RNA was isolated from fetal and adult MSC. Using SMART PCR synthesis method, single-strand and double-strand cDNAs were synthesized. After Rsa I digestion, fetal MSC cDNAs were divided into two groups and ligated to adaptor 1 and adaptor 2 respectively. Results showed that the amplified library contains 890 clones. Analysis of 890 clones with PCR demonstrated that 768 clones were positive. The positive rate is 86.3%. The size of inserted fragments in these positive clones was between 0.2 - 1 kb, with an average of 400 - 600 bp. SSH is a convenient and effective method for screening differentially expressed genes. The constructed cDNA subtractive library of fetal MSC cDNA lays solid foundation for screening and cloning new and specific function related genes of fetal MSC.

  15. IMPROVED BACKGROUND SUBTRACTION FOR THE SLOAN DIGITAL SKY SURVEY IMAGES

    International Nuclear Information System (INIS)

    Blanton, Michael R.; Kazin, Eyal; Muna, Demitri; Weaver, Benjamin A.; Price-Whelan, Adrian

    2011-01-01

    We describe a procedure for background subtracting Sloan Digital Sky Survey (SDSS) imaging that improves the resulting detection and photometry of large galaxies on the sky. Within each SDSS drift scan run, we mask out detected sources and then fit a smooth function to the variation of the sky background. This procedure has been applied to all SDSS-III Data Release 8 images, and the results are available as part of that data set. We have tested the effect of our background subtraction on the photometry of large galaxies by inserting fake galaxies into the raw pixels, reanalyzing the data, and measuring them after background subtraction. Our technique results in no size-dependent bias in galaxy fluxes up to half-light radii r 50 ∼ 100 arcsec; in contrast, for galaxies of that size the standard SDSS photometric catalog underestimates fluxes by about 1.5 mag. Our results represent a substantial improvement over the standard SDSS catalog results and should form the basis of any analysis of nearby galaxies using the SDSS imaging data.

  16. A quantum architecture for multiplying signed integers

    International Nuclear Information System (INIS)

    Alvarez-Sanchez, J J; Alvarez-Bravo, J V; Nieto, L M

    2008-01-01

    A new quantum architecture for multiplying signed integers is presented based on Booth's algorithm, which is well known in classical computation. It is shown how a quantum binary chain might be encoded by its flank changes, giving the final product in 2's-complement representation.

  17. Computed tomography lung iodine contrast mapping by image registration and subtraction

    Science.gov (United States)

    Goatman, Keith; Plakas, Costas; Schuijf, Joanne; Beveridge, Erin; Prokop, Mathias

    2014-03-01

    Pulmonary embolism (PE) is a relatively common and potentially life threatening disease, affecting around 600,000 people annually in the United States alone. Prompt treatment using anticoagulants is effective and saves lives, but unnecessary treatment risks life threatening haemorrhage. The specificity of any diagnostic test for PE is therefore as important as its sensitivity. Computed tomography (CT) angiography is routinely used to diagnose PE. However, there are concerns it may over-report the condition. Additional information about the severity of an occlusion can be obtained from an iodine contrast map that represents tissue perfusion. Such maps tend to be derived from dual-energy CT acquisitions. However, they may also be calculated by subtracting pre- and post-contrast CT scans. Indeed, there are technical advantages to such a subtraction approach, including better contrast-to-noise ratio for the same radiation dose, and bone suppression. However, subtraction relies on accurate image registration. This paper presents a framework for the automatic alignment of pre- and post-contrast lung volumes prior to subtraction. The registration accuracy is evaluated for seven subjects for whom pre- and post-contrast helical CT scans were acquired using a Toshiba Aquilion ONE scanner. One hundred corresponding points were annotated on the pre- and post-contrast scans, distributed throughout the lung volume. Surface-to-surface error distances were also calculated from lung segmentations. Prior to registration the mean Euclidean landmark alignment error was 2.57mm (range 1.43-4.34 mm), and following registration the mean error was 0.54mm (range 0.44-0.64 mm). The mean surface error distance was 1.89mm before registration and 0.47mm after registration. There was a commensurate reduction in visual artefacts following registration. In conclusion, a framework for pre- and post-contrast lung registration has been developed that is sufficiently accurate for lung subtraction

  18. Clinical utility of Gd-DTPA subtraction MR imaging for spinal bone metastasis

    International Nuclear Information System (INIS)

    Ando, Keiichi; Murakami, Masao; Kuroda, Yasumasa

    1993-01-01

    Based on reports that Gd-DTPA contributes to the detection of tumors, we used it in 31 cases (97 lesions) of spinal bone metastases. The result was that Gd-DTPA increased the intensity of tumors and the surrounding bone marrow to almost the same level in 53%. To show the metastases clearly, an existing subtraction command system was utilized. The technique included the pixel-by-pixel method, to obtain a Gd-DTPA T1-weighted image (T1WI) subtracted by the original T1WI. The detectability of the subtraction image was improved up to 96%, but was less than the original T1WI (99%). Because of the different imaging rationale between two methods, a means to assess the quality of diagnosis must be proposed. To check the normal background, the same kind of postprocessing was performed in 21 patients without malignancy. Gd-DTPA prefusion was highest in the paravertebral veins, moderate in muscles and epidural fat, and lowest in the spinal cord, intervertebral disk and bone cortex. Gd-DTPA enhanced subtraction MR imaging provides a new diagnostic tool to detect and to assess bone metastasis. (author)

  19. The South African wildlife ranching sector: A Social Accounting Matrix Leontief multiplier analysis

    Directory of Open Access Journals (Sweden)

    Philippus C. Cloete

    2014-10-01

    Research purpose: The purpose of this article is to put into context the relative economic contribution of the wildlife ranching sector, as opposed to other land-use options in South Africa. Motivation for the study: Growth in the wildlife ranching sector at the cost of other traditional farming practices resulted in disagreements amongst various role players about the impact thereof on the national economy. The controversy can most probably be explained by different beliefs, coupled with the lack of a proper understanding and quantification of the wildlife ranching sector’s contribution toward the economy. Research methodology: The study employed a Social Accounting Matrix-based Leontief multiplier analysis for South Africa. Main findings: Results from the multiplier analysis revealed that developments within the wildlife ranching sector are likely to make a relatively more superior contribution towards the economy, especially when compared to similar land-use options such as extensive livestock production. Practical/managerial implications: It has been acknowledged by both academia and private sector that a major need exists for more research on the South African wildlife ranching industry, specifically looking at issues such as the industries, economic and social contributions, potentials and constraints. The research, therefore, contributes toward the depth of economic information and research regarding the South African wildlife sector. Contribution/value added: The research provides valuable information in dealing with the ‘popular belief’, especially amongst some of South Africa’s decision makers, namely, that growth in the wildlife ranching sector is not or does not have the ability to contribute significantly toward economic and socioeconomic factors.

  20. Hybrid intravenous digital subtraction angiography of the carotid bifurcation

    International Nuclear Information System (INIS)

    Burbank, F.H.; Enzmann, D.; Keyes, G.S.; Brody, W.R.

    1984-01-01

    A hybrid digital subtraction angiography technique and noise-reduction algorithm were used to evaluate the carotid bifurcation. Temporal, hybrid, and reduced-noise hybrid images were obtained in right and left anterior oblique projections, and both single- and multiple-frame images were created with each method. The resulting images were graded on a scale of 1 to 5 by three experienced neuroradiologists. Temporal images were preferred over hybrid images. The percentage of nondiagnostic examinations, as agreed upon by two readers, was higher for temporal alone than temporal + hybrid. In addition, also by agreement between two readers, temporal + hybrid images significantly increased the number of bifurcations seen in two views (87%) compared to temporal subtraction alone

  1. Tomosynthesis applied to digital subtraction angiography

    International Nuclear Information System (INIS)

    Kruger, R.A.; Sedaghati, M.; Roy, D.G.; Liu, P.; Nelson, J.A.; Kubal, W.; Del Rio, P.

    1984-01-01

    This extension of the author's previous work on tomographic digital subtraction angiography (DSA) describes the theory of tomosynthetic DSA image reconstruction techniques. In addition to developing the resolution limits resulting from x-ray exposure length and image intensifier field curvature, the authors describe one method of image formation and show tomosynthetic DSA images of animal and human anatomy. Methods for improving the present technique are discussed

  2. Digital subtraction angiography

    International Nuclear Information System (INIS)

    Neuwirth, J. Jr.; Bohutova, J.

    1987-01-01

    The quality of radiodiagnostic methods to a great extent depends on the quality of the resulting image. The basic technical principles are summed up of the different parts of digital subtraction angiography apparatus and of methods of improving the image. The instrument is based on a videochain consisting of an X-ray tube, an intensifier of the radiographic image, optical parts, a video camera, an analog-to-digital converter and a computer. The main advantage of the digitally processed image is the possibility of optimizing the image into a form which will contain the biggest amount of diagnostically valuable information. Described are the mathematical operations for improving the digital image: spatial filtration, pixel shift, time filtration, image integration, time interval differentation and matched filtering. (M.D.). 8 refs., 3 figs

  3. Preoperative radiological diagnosis by 99mTc·MIBI-99mTc subtraction scintigraphy for primary hyperparathyroidism

    International Nuclear Information System (INIS)

    Inouye, Takahiro; Tomita, Toshiki; Shinden, Seiichi; Takagi, Hitoshi; Kano, Shigeru.

    1996-01-01

    Preoperative radiological diagnosis constitutes the most important factor for the surgical treatment of hyperparathyroidism. In this regard, MRI is useful for detecting the abnormal parathyroid, but it is often difficult to localize it using MRI only. It is thus necessary to combine this procedure with excellent subtraction scintigraphy. We performed both 201 Tl- 99m Tc and 99m Tc·MIBI- 99m Tc subtraction scintigraphy in seven patients with primary hyperparathyroidism and compared them the radiological results. Five patients presented parathyroid adenomas and the rest hypertrophy of the parathyroid. We could detect the abnormal parathyroid in four patients (57.1%) by 201 Tl- 99m Tc subtraction scintigraphy and in six patients (85.7%) by 99m Tc·MIBI- 99m Tc subtraction scintigraphy. We therefore believe that 99m Tc·MIBI- 99m Tc subtraction scintigraphy will become an essential examination for primary hyperparathyroidism rather than the presently employed 201 Tl- 99m Tc subtraction scintigraphy. (author)

  4. Parathyroid localizlation by 201Tl-99mTc subtraction scintigraphy

    International Nuclear Information System (INIS)

    Rademaker, P.; Meijer, S.; Piers, D.A.

    1990-01-01

    Subtraction scintigraphy with 201 Tl and 99m Tc for parathyroid localization was performed preoperatively in 13 patients with chronic renal failure and secondary hyperparathyroidism. Twenty of the 37 examined pathological glands were predicted correctly (sensitivity 54%). In 3 patients with recurrent hyperparathyroidism after surgery all pathological glands found at second operation had been detected correctly by subtraction scintigraphy. We conclude that this localization method has a limited value when used prior to first neck exploration in secondary hyperparathyroidism. In persistent hyperparathyroidism after surgery it may play a useful role in localizing missed and ectopic glands. (author)

  5. Informed baseline subtraction of proteomic mass spectrometry data aided by a novel sliding window algorithm.

    Science.gov (United States)

    Stanford, Tyman E; Bagley, Christopher J; Solomon, Patty J

    2016-01-01

    Proteomic matrix-assisted laser desorption/ionisation (MALDI) linear time-of-flight (TOF) mass spectrometry (MS) may be used to produce protein profiles from biological samples with the aim of discovering biomarkers for disease. However, the raw protein profiles suffer from several sources of bias or systematic variation which need to be removed via pre-processing before meaningful downstream analysis of the data can be undertaken. Baseline subtraction, an early pre-processing step that removes the non-peptide signal from the spectra, is complicated by the following: (i) each spectrum has, on average, wider peaks for peptides with higher mass-to-charge ratios ( m / z ), and (ii) the time-consuming and error-prone trial-and-error process for optimising the baseline subtraction input arguments. With reference to the aforementioned complications, we present an automated pipeline that includes (i) a novel 'continuous' line segment algorithm that efficiently operates over data with a transformed m / z -axis to remove the relationship between peptide mass and peak width, and (ii) an input-free algorithm to estimate peak widths on the transformed m / z scale. The automated baseline subtraction method was deployed on six publicly available proteomic MS datasets using six different m/z-axis transformations. Optimality of the automated baseline subtraction pipeline was assessed quantitatively using the mean absolute scaled error (MASE) when compared to a gold-standard baseline subtracted signal. Several of the transformations investigated were able to reduce, if not entirely remove, the peak width and peak location relationship resulting in near-optimal baseline subtraction using the automated pipeline. The proposed novel 'continuous' line segment algorithm is shown to far outperform naive sliding window algorithms with regard to the computational time required. The improvement in computational time was at least four-fold on real MALDI TOF-MS data and at least an order of

  6. A microchannel plate X-ray multiplier with rising-time less than 170 ps

    International Nuclear Information System (INIS)

    Zhao Shicheng; Ouyang Bin

    1987-01-01

    The time reponse of a microchannel plate X-ray multiplier has been improved considerably by using a coupling construction of coaxial tapers. The experimental calibration results with laser plasma X-ray source show that the rising-time of the multiplier is less than 170 ps

  7. Addition and Subtraction but Not Multiplication and Division Cause Shifts of Spatial Attention

    Directory of Open Access Journals (Sweden)

    Mengjin Li

    2018-05-01

    Full Text Available Many studies have shown that solving addition and subtraction problems can induce overt shifts of spatial attention. In particular, right-side targets are detected faster than left-side targets when preceded by an addition operation, while left-side targets are detected faster than right-side targets when preceded by a subtraction operation. However, the interaction between space and arithmetic in multiplication or division is hardly studied and remains controversial. In order to make a strong case for the interaction between space and mental arithmetic, we attempted to replicate the spatial-arithmetic association in addition and subtraction (Experiment 1, and at the same time investigated whether shift of spatial attention would also be induced by multiplication or division operations (Experiment 2. We found that solving addition problems facilitated the detection of right-side targets, whereas left-side targets were detected faster after solving subtraction problems. However, no interaction between space and arithmetic operation was observed in multiplication or division. The implication of these findings is discussed.

  8. Proximal caries detection using digital subtraction radiography in the artificial caries activity model

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jong Hoon; Lee, Gi Ja; Choi, Sam Jin; Park, Young Ho; Kim, Kyung Soo; Jin, Hyun Seok; Hong, Kyung Won; Oh, Berm Seok; Park, Hun Kuk [Department of Biomedical Engineering, School of Medicine, Kyung Hee University, Seoul (Korea, Republic of); Choi, Yong Suk; Hwang, Eui Hwan [Department of Oral and Maxillofacial Radiology, Institute of Oral Biology, School of Dentistry, Kyung Hee University, Seoul (Korea, Republic of)

    2009-03-15

    The purpose of the experiment was to evaluating the diagnostic ability of dental caries detection using digital subtraction in the artificial caries activity model. Digital radiographs of five teeth with 8 proximal surfaces were obtained by CCD sensor (Kodak RVG 6100 using a size no.2). The digital radiographic images and subtraction images from artificial proximal caries were examined and interpreted. In this study, we proposed novel caries detection method which could diagnose the dental proximal caries from single digital radiographic image. In artificial caries activity model, the range of lesional depth was 572-1,374 {mu}m and the range of lesional area was 36.95-138.52 mm{sup 2}. The lesional depth and the area were significantly increased with demineralization time (p<0.001). Furthermore, the proximal caries detection using digital subtraction radiography showed high detection rate compared to the proximal caries examination using simple digital radiograph. The results demonstrated that the digital subtraction radiography from single radiographic image of artificial caries was highly efficient in the detection of dental caries compared to the data from simple digital radiograph.

  9. Proximal caries detection using digital subtraction radiography in the artificial caries activity model

    International Nuclear Information System (INIS)

    Park, Jong Hoon; Lee, Gi Ja; Choi, Sam Jin; Park, Young Ho; Kim, Kyung Soo; Jin, Hyun Seok; Hong, Kyung Won; Oh, Berm Seok; Park, Hun Kuk; Choi, Yong Suk; Hwang, Eui Hwan

    2009-01-01

    The purpose of the experiment was to evaluating the diagnostic ability of dental caries detection using digital subtraction in the artificial caries activity model. Digital radiographs of five teeth with 8 proximal surfaces were obtained by CCD sensor (Kodak RVG 6100 using a size no.2). The digital radiographic images and subtraction images from artificial proximal caries were examined and interpreted. In this study, we proposed novel caries detection method which could diagnose the dental proximal caries from single digital radiographic image. In artificial caries activity model, the range of lesional depth was 572-1,374 μm and the range of lesional area was 36.95-138.52 mm 2 . The lesional depth and the area were significantly increased with demineralization time (p<0.001). Furthermore, the proximal caries detection using digital subtraction radiography showed high detection rate compared to the proximal caries examination using simple digital radiograph. The results demonstrated that the digital subtraction radiography from single radiographic image of artificial caries was highly efficient in the detection of dental caries compared to the data from simple digital radiograph.

  10. Novel Ratio Subtraction and Isoabsorptive Point Methods for ...

    African Journals Online (AJOL)

    Purpose: To develop and validate two innovative spectrophotometric methods used for the simultaneous determination of ambroxol hydrochloride and doxycycline in their binary mixture. Methods: Ratio subtraction and isoabsorptive point methods were used for the simultaneous determination of ambroxol hydrochloride ...

  11. A CMOS four-quadrant analog current multiplier

    NARCIS (Netherlands)

    Wiegerink, Remco J.

    1991-01-01

    A CMOS four-quadrant analog current multiplier is described. The circuit is based on the square-law characteristic of an MOS transistor and is insensitive to temperature and process variations. The circuit is insensitive to the body effect so it is not necessary to place transistors in individual

  12. A simultaneous all-optical half/full-subtraction strategy using cascaded highly nonlinear fibers

    Science.gov (United States)

    Singh, Karamdeep; Kaur, Gurmeet; Singh, Maninder Lal

    2018-02-01

    Using non-linear effects such as cross-gain modulation (XGM) and cross-phase modulation (XPM) inside two highly non-linear fibres (HNLF) arranged in cascaded configuration, a simultaneous half/full-subtracter is proposed. The proposed simultaneous half/full-subtracter design is attractive due to several features such as input data pattern independence and usage of minimal number of non-linear elements i.e. HNLFs. Proof of concept simulations have been conducted at 100 Gbps rate, indicating fine performance, as extinction ratio (dB) > 6.28 dB and eye opening factors (EO) > 77.1072% are recorded for each implemented output. The proposed simultaneous half/full-subtracter can be used as a key component in all-optical information processing circuits.

  13. Background dose subtraction in personnel dosimetry

    International Nuclear Information System (INIS)

    Picazo, T.; Llorca, N.; Alabau, J.

    1997-01-01

    In this paper it is proposed to consider the mode of the frequency distribution of the low dose dosemeters from each clinic that uses X rays as the background environmental dose that should be subtracted from the personnel dosimetry to evaluate the doses due to practice. The problems and advantages of this indirect method to estimate the environmental background dose are discussed. The results for 60 towns are presented. (author)

  14. Bone images from dual-energy subtraction chest radiography in the detection of rib fractures.

    Science.gov (United States)

    Szucs-Farkas, Zsolt; Lautenschlager, Katrin; Flach, Patricia M; Ott, Daniel; Strautz, Tamara; Vock, Peter; Ruder, Thomas D

    2011-08-01

    To assess the sensitivity and image quality of chest radiography (CXR) with or without dual-energy subtracted (ES) bone images in the detection of rib fractures. In this retrospective study, 39 patients with 204 rib fractures and 24 subjects with no fractures were examined with a single exposure dual-energy subtraction digital radiography system. Three blinded readers first evaluated the non-subtracted posteroanterior and lateral chest radiographs alone, and 3 months later they evaluated the non-subtracted images together with the subtracted posteroanterior bone images. The locations of rib fractures were registered with confidence levels on a 3-grade scale. Image quality was rated on a 5-point scale. Marks by readers were compared with fracture localizations in CT as a standard of reference. The sensivity for fracture detection using both methods was very similar (34.3% with standard CXR and 33.5% with ES-CXR, p=0.92). At the patient level, both sensitivity (71.8%) and specificity (92.9%) with or without ES were identical. Diagnostic confidence was not significantly different (2.61 with CXR and 2.75 with ES-CXR, p=0.063). Image quality with ES was rated higher than that on standard CXR (4.08 vs. 3.74, prib fractures. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  15. Digital subtraction angiography in the assessment of cardiovascular disease

    International Nuclear Information System (INIS)

    Harrington, D.P.; Boxt, L.M.

    1985-01-01

    Digital subtraction angiography (DSA) is a new radiographic method for evaluating the cardiovascular system. It represents another in a continuing series of computer-assisted diagnostic imaging modalities. The advantages of this technique are its relatively noninvasive nature combined with diagnostically acceptable angiographic images of a variety of cardiovascular structures. Major clinical applications of DSA include its use in imaging of localized regions of peripheral arterial disease and as a screening procedure in evaluating extracranial carotid and vertebral artery disease and renovascular hypertension. Cardiac applications of DSA include assessment of ventricular function, recognition and quantification of intracardiac shunts, visualization of coronary artery bypass grafts, and the study of complex congenital cardiac malformations. Digital subtraction angiography may also be used to evaluate intracranial aneurysms and vascular tumors

  16. Spinal pedicle subtraction osteotomy for fixed sagittal imbalance patients

    Science.gov (United States)

    Hyun, Seung-Jae; Kim, Yongjung J; Rhim, Seung-Chul

    2013-01-01

    In addressing spinal sagittal imbalance through a posterior approach, the surgeon now may choose from among a variety of osteotomy techniques. Posterior column osteotomies such as the facetectomy or Ponte or Smith-Petersen osteotomy provide the least correction, but can be used at multiple levels with minimal blood loss and a lower operative risk. Pedicle subtraction osteotomies provide nearly 3 times the per-level correction of Ponte/Smith-Petersen osteotomies; however, they carry increased technical demands, longer operative time, and greater blood loss and associated significant morbidity, including neurological injury. The literature focusing on pedicle subtraction osteotomy for fixed sagittal imbalance patients is reviewed. The long-term overall outcomes, surgical tips to reduce the complications and suggestions for their proper application are also provided. PMID:24340276

  17. Introduction to the principles of Digital Subtraction Angiography (DSA)

    Energy Technology Data Exchange (ETDEWEB)

    Kaplanis, P [Medical Physics Department, Nicosia General Hospital, Nicosia (Cyprus)

    1998-12-31

    Medical applications of advanced technology have rapidly become more sophisticated and more widespread. The field of diagnostic imaging is by no means an exception. There has been a number of breathtaking developments in the field of medical imaging in recent years. Today higher quality, greater clarity and more minute precision are considered not advantages but necessities. Hence new developments are concentrated in the data acquisition and image processing based on the microprocessor controlled modules interfaced with state of the art radiological imaging equipment. One such development is the subtraction of x-rays vis a computer for better visualization of blood vessels, cavities of the heart and of the coronary and pulmonary vascular system. This procedure is termed Digital Subtraction Angiography (DSA). (author). 5 refs, 3 figs.

  18. Introduction to the principles of Digital Subtraction Angiography (DSA)

    International Nuclear Information System (INIS)

    Kaplanis, P.

    1997-01-01

    Medical applications of advanced technology have rapidly become more sophisticated and more widespread. The field of diagnostic imaging is by no means an exception. There has been a number of breathtaking developments in the field of medical imaging in recent years. Today higher quality, greater clarity and more minute precision are considered not advantages but necessities. Hence new developments are concentrated in the data acquisition and image processing based on the microprocessor controlled modules interfaced with state of the art radiological imaging equipment. One such development is the subtraction of x-rays vis a computer for better visualization of blood vessels, cavities of the heart and of the coronary and pulmonary vascular system. This procedure is termed Digital Subtraction Angiography (DSA). (author)

  19. Neutron fluctuations in a multiplying medium randomly varying in time

    Energy Technology Data Exchange (ETDEWEB)

    Pal, L. [KFKI Atomic Energy Research Inst., Budapest (Hungary); Pazsit, I. [Chalmers Univ. of Technology, Goeteborg (Sweden). Dept. of Nuclear Engineering

    2006-07-15

    The master equation approach, which has traditionally been used for the calculation of neutron fluctuations in multiplying systems with constant parameters, is extended to a case when the parameters of the system change randomly in time. A forward type master equation is considered for the case of a multiplying system whose properties jump randomly between two discrete states, both with and without a stationary external source. The first two factorial moments are calculated, including the covariance. This model can be considered as the unification of stochastic methods that were used either in a constant multiplying medium via the master equation technique, or in a fluctuating medium via the Langevin technique. The results obtained show a much richer characteristic of the zero power noise than that in constant systems. The results are relevant in medium power subcritical nuclear systems where the zero power noise is still significant, but they also have a bearing on all types of branching processes, such as evolution of biological systems, spreading of epidemics etc, which are set in a time-varying environment.

  20. Neutron fluctuations in a multiplying medium randomly varying in time

    International Nuclear Information System (INIS)

    Pal, L.; Pazsit, I.

    2006-01-01

    The master equation approach, which has traditionally been used for the calculation of neutron fluctuations in multiplying systems with constant parameters, is extended to a case when the parameters of the system change randomly in time. A forward type master equation is considered for the case of a multiplying system whose properties jump randomly between two discrete states, both with and without a stationary external source. The first two factorial moments are calculated, including the covariance. This model can be considered as the unification of stochastic methods that were used either in a constant multiplying medium via the master equation technique, or in a fluctuating medium via the Langevin technique. The results obtained show a much richer characteristic of the zero power noise than that in constant systems. The results are relevant in medium power subcritical nuclear systems where the zero power noise is still significant, but they also have a bearing on all types of branching processes, such as evolution of biological systems, spreading of epidemics etc, which are set in a time-varying environment

  1. Atlantic Richfield Hanford Company californium multiplier/delayed neutron counter safety analysis

    International Nuclear Information System (INIS)

    Zimmer, W.H.

    1976-08-01

    The Californium Multiplier (CFX) is a subcritical assembly of uranium surrounding 252 Cf spontaneously fissioning neutron sources; its function is to multiply the neutron flux to a level useful for activation analysis. This document summarizes the safety analysis aspects of the CFX, DNC, pneumatic transfer system, and instrumentation and to detail all the aspects of the total facility as a starting point for the ARHCO Safety Analysis Review. Recognized hazards and steps already taken to neutralize them are itemized

  2. Economic Multipliers and Sectoral Linkages: Ghana and the New Oil Sector

    Directory of Open Access Journals (Sweden)

    Dennis Nchor

    2016-01-01

    Full Text Available The study seeks to assess the structure of the economy of Ghana in terms of changes in the economic structure before and after the production of oil in commercial quantities. This is viewed with regards to economic multipliers, sectoral interdependence and trade concentration. The results show that changes occurred with regards to multipliers and sectoral interdependence. The output multipliers of most sectors have declined. The results also show that the agricultural sector experienced an initial decline in its growth while industry experienced an increase. The performance of the services sector was relatively stable for the period covered by the study. There is a decline in the level of trade concentration though on a whole the concentration index is still high. The study employed input-output modeling techniques and the data was obtained from the Ghana statistical service and the World Development Indicators.

  3. Four-State Continuous-Variable Quantum Key Distribution with Photon Subtraction

    Science.gov (United States)

    Li, Fei; Wang, Yijun; Liao, Qin; Guo, Ying

    2018-06-01

    Four-state continuous-variable quantum key distribution (CVQKD) is one of the discretely modulated CVQKD which generates four nonorthogonal coherent states and exploits the sign of the measured quadrature of each state to encode information rather than uses the quadrature \\hat {x} or \\hat {p} itself. It has been proven that four-state CVQKD is more suitable than Gaussian modulated CVQKD in terms of transmission distance. In this paper, we propose an improved four-state CVQKD using an non-Gaussian operation, photon subtraction. A suitable photon-subtraction operation can be exploited to improve the maximal transmission of CVQKD in point-to-point quantum communication since it provides a method to enhance the performance of entanglement-based (EB) CVQKD. Photon subtraction not only can lengthen the maximal transmission distance by increasing the signal-to-noise rate but also can be easily implemented with existing technologies. Security analysis shows that the proposed scheme can lengthen the maximum transmission distance. Furthermore, by taking finite-size effect into account we obtain a tighter bound of the secure distance, which is more practical than that obtained in the asymptotic limit.

  4. A subtraction scheme for computing QCD jet cross sections at NNLO: integrating the doubly unresolved subtraction terms

    CERN Document Server

    Somogyi, Gabor

    2013-01-01

    We finish the definition of a subtraction scheme for computing NNLO corrections to QCD jet cross sections. In particular, we perform the integration of the soft-type contributions to the doubly unresolved counterterms via the method of Mellin-Barnes representations. With these final ingredients in place, the definition of the scheme is complete and the computation of the regularised doubly virtual contribution to the NNLO cross section becomes feasible.

  5. Misconception on Addition and Subtraction of Fraction at Primary School Students in Fifth-Grade

    Science.gov (United States)

    Trivena, V.; Ningsih, A. R.; Jupri, A.

    2017-09-01

    This study aims to investigate the mastery concept of the student in mathematics learning especially in addition and subtraction of fraction at primary school level. By using qualitative research method, the data were collected from 23 grade five students (10-11-year-old). Instruments included a test, that is accompanied by Certainty Response Index (CRI) and interview with students and teacher. The result of the test has been obtained, then processed by analyzing the student’s answers for each item and then grouped by the CRI categories that combined with the results of the interview with students and teacher. The results showed that student’s mastery-concept on additional and subtraction dominated by category ‘misconception’. So, we can say that mastery-concept on addition and subtraction of fraction at fifth-grade students is still low. Finally, the impact can make most of primary student think that learning addition and subtraction of fraction in mathematics is difficult.

  6. Human reliability under sleep deprivation: Derivation of performance shaping factor multipliers from empirical data

    International Nuclear Information System (INIS)

    Griffith, Candice D.; Mahadevan, Sankaran

    2015-01-01

    This paper develops a probabilistic approach that could use empirical data to derive values of performance shaping factor (PSF) multipliers for use in quantitative human reliability analysis (HRA). The proposed approach is illustrated with data on sleep deprivation effects on performance. A review of existing HRA methods reveals that sleep deprivation is not explicitly included at present, and expert opinion is frequently used to inform HRA model multipliers. In this paper, quantitative data from empirical studies regarding the effect of continuous hours of wakefulness on performance measures (reaction time, accuracy, and number of lapses) are used to develop a method to derive PSF multiplier values for sleep deprivation, in the context of the SPAR-H model. Data is extracted from the identified studies according to the meta-analysis research synthesis method and used to investigate performance trends and error probabilities. The error probabilities in test and control conditions are compared, and the resulting probability ratios are suggested for use in informing the selection of PSF multipliers in HRA methods. Although illustrated for sleep deprivation, the proposed methodology is general, and can be applied to other performance shaping factors. - Highlights: • Method proposed to derive performance shaping factor multipliers from empirical data. • Studies reporting the effect of sleep deprivation on performance are analyzed. • Test data using psychomotor vigilance tasks are analyzed. • Error probability multipliers computed for reaction time, lapses, and accuracy measures.

  7. Multiplying dimensions

    CERN Multimedia

    2013-01-01

    A few weeks ago, I had a vague notion of what TED was, and how it worked, but now I’m a confirmed fan. It was my privilege to host CERN’s first TEDx event last Friday, and I can honestly say that I can’t remember a time when I was exposed to so much brilliance in such a short time.   TEDxCERN was designed to give a platform to science. That’s why we called it Multiplying Dimensions – a nod towards the work we do here, while pointing to the broader importance of science in society. We had talks ranging from the most subtle pondering on the nature of consciousness to an eighteen year old researcher urging us to be patient, and to learn from our mistakes. We had musical interludes that included encounters between the choirs of local schools and will.i.am, between an Israeli pianist and an Iranian percussionist, and between Grand Opera and high humour. And although I opened the event by announcing it as a day off from physics, we had a quite brill...

  8. Two-dimensional real-time imaging system for subtraction angiography using an iodine filter

    Science.gov (United States)

    Umetani, Keiji; Ueda, Ken; Takeda, Tohoru; Anno, Izumi; Itai, Yuji; Akisada, Masayoshi; Nakajima, Teiichi

    1992-01-01

    A new type of subtraction imaging system was developed using an iodine filter and a single-energy broad bandwidth monochromatized x ray. The x-ray images of coronary arteries made after intravenous injection of a contrast agent are enhanced by an energy-subtraction technique. Filter chopping of the x-ray beam switches energies rapidly, so that a nearly simultaneous pair of filtered and nonfiltered images can be made. By using a high-speed video camera, a pair of two 512 × 512 pixel images can be obtained within 9 ms. Three hundred eighty-four images (raw data) are stored in a 144-Mbyte frame memory. After phantom studies, in vivo subtracted images of coronary arteries in dogs were obtained at a rate of 15 images/s.

  9. Venous digital subtraction angiography for diagnosis of renal artery stenosis in arterial hypertony

    International Nuclear Information System (INIS)

    Schoerner, W.; Kempter, H.; Banzer, D.; Aviles, C.; Weiss, T.; Felix, R.

    1984-01-01

    Venous digital subtraction angiography was performed in 248 patients for the diagnosis of renal arterial stenosis. In 88% of the investigations the stenosis could be found. Comparison of digital angiography and conventional angiography was made for 57 renal arteries (25 investigations). In 52 renal arteries we found the same results with both methods, in 5 renal arteries we found the same results with both methods, in 5 renal arteries the digital angiography showed false positive results. The spatial resolution of digital subtraction angiography is sufficient for the correct diagnosis of significant renal arterial stenosis. With regard to the lower invasion of digital subtraction angiography compared to conventional angiography the first method should be used for clarification of renal arterial hypertension. (orig.)

  10. Digital Subtraction Angiography (DSA) "Road Map": An Angiographic Tool

    Science.gov (United States)

    Turski, P. A.; Stieghorst, M. F.; Strother, C. M.; Crummy, A. B.; Lieberman, R. P.; Mistretta, C. A.

    1982-12-01

    Continuous Digital subtraction combined with intraarterial injections of contrast medium permits the display of arterial structures during real time fluoroscopy. This DSA "road map" facilitates selective catheterization and has proved useful in interventional procedures.

  11. Comparison of two interpolative background subtraction methods using phantom and clinical data

    International Nuclear Information System (INIS)

    Houston, A.S.; Sampson, W.F.D.

    1989-01-01

    Two interpolative background subtraction methods used in scintigraphy are tested using both phantom and clinical data. Cauchy integral subtraction was found to be relatively free of artefacts but required more computing time than bilinear interpolation. Both methods may be used with reasonable confidence for the quantification of relative measurements such as left ventricular ejection fraction and myocardial perfusion index but should be avoided if at all possible in the quantification of absolute measurements such as glomerular filtration rate. (author)

  12. Clinical application of subtraction CT imaging for evaluation of pulmonary vascular permeability

    International Nuclear Information System (INIS)

    Kato, Shiro; Asai, Toshihiko; Yatagai, Shigeo; Oonuma, Noboru; Ohno, Kunihiko; Nakamoto, Takaaki; Iizuka, Masahiko

    1991-01-01

    In this clinical study, one normal subject, one patient with primary interstitial pneumonia, one patient with segmental pneumonia due to Staphylococcus aureus, one patient with post-operative esophageal carcinoma, and two patients with mitral stenosis were studied. Dynamic CT scan images under continuous injection of low osmotic contrast medium were analyzed in series, in an attempt to evaluate vascular permeability quantitatively. The following results were obtained. Subtraction CT scan image 10 minutes after the start of contrast medium injection in two patients with pneumonia, showed a reduction of pulmonary vascular permeability following therapy. Subtraction CT scan image of the patient with post-operative esophageal carcinoma treated with 25 Gy radiation showed a discrepancy between pulmonary vascular permeability and other findings. In hemodynamically stable patients with mitral stenosis, subtraction CT images demonstrated that pulmonary vascular permeability was not affected by pulmonary congestion, irrespective of its severity. (author)

  13. A subtraction scheme for computing QCD jet cross sections at NNLO: integrating the doubly unresolved subtraction terms

    Science.gov (United States)

    Somogyi, Gábor

    2013-04-01

    We finish the definition of a subtraction scheme for computing NNLO corrections to QCD jet cross sections. In particular, we perform the integration of the soft-type contributions to the doubly unresolved counterterms via the method of Mellin-Barnes representations. With these final ingredients in place, the definition of the scheme is complete and the computation of fully differential rates for electron-positron annihilation into two and three jets at NNLO accuracy becomes feasible.

  14. A subtraction scheme for computing QCD jet cross sections at NNLO: integrating the doubly unresolved subtraction terms

    OpenAIRE

    Somogyi, Gabor

    2013-01-01

    We finish the definition of a subtraction scheme for computing NNLO corrections to QCD jet cross sections. In particular, we perform the integration of the soft-type contributions to the doubly unresolved counterterms via the method of Mellin-Barnes representations. With these final ingredients in place, the definition of the scheme is complete and the computation of fully differential rates for electron-positron annihilation into two and three jets at NNLO accuracy becomes feasible.

  15. A High-Speed Design of Montgomery Multiplier

    Science.gov (United States)

    Fan, Yibo; Ikenaga, Takeshi; Goto, Satoshi

    With the increase of key length used in public cryptographic algorithms such as RSA and ECC, the speed of Montgomery multiplication becomes a bottleneck. This paper proposes a high speed design of Montgomery multiplier. Firstly, a modified scalable high-radix Montgomery algorithm is proposed to reduce critical path. Secondly, a high-radix clock-saving dataflow is proposed to support high-radix operation and one clock cycle delay in dataflow. Finally, a hardware-reused architecture is proposed to reduce the hardware cost and a parallel radix-16 design of data path is proposed to accelerate the speed. By using HHNEC 0.25μm standard cell library, the implementation results show that the total cost of Montgomery multiplier is 130 KGates, the clock frequency is 180MHz and the throughput of 1024-bit RSA encryption is 352kbps. This design is suitable to be used in high speed RSA or ECC encryption/decryption. As a scalable design, it supports any key-length encryption/decryption up to the size of on-chip memory.

  16. Enriching Addition and Subtraction Fact Mastery through Games

    Science.gov (United States)

    Bay-Williams, Jennifer M.; Kling, Gina

    2014-01-01

    The learning of "basic facts"--single-digit combinations for addition, subtraction, multiplication, and division--has long been a focus of elementary school mathematics. Many people remember completing endless worksheets, timed tests, and flash card drills as they attempted to "master" their basic facts as children. However,…

  17. Improvement in visibility of simulated lung nodules on computed radiography (CR) chest images by use of temporal subtraction technique

    International Nuclear Information System (INIS)

    Oda, Nobuhiro; Fujimoto, Keiji; Murakami, Seiichi; Katsuragawa, Shigehiko; Doi, Kunio; Nakata, Hajime

    1999-01-01

    A temporal subtraction image obtained by subtraction of a previous image from a current one can enhance interval change on chest images. In this study, we compared the visibility of simulated lung nodules on CR images with and without temporal subtraction. Chest phantom images without and with simulated nodules were obtained as previous and current images, respectively, by a CR system. Then, subtraction images were produced with an iterative image warping technique. Twelve simulated nodules were attached on various locations of the chest phantom. The diameter of nodules having a CT number of 47 ranged from 3 mm to 10 mm. Seven radiologists subjectively evaluated the visibility of simulated nodules on CR images with and without temporal subtraction using a three-point rating scale (0: invisible, +1: questionable, +2:visible). The minimum diameter of simulated nodules visible at a frequency greater than 50% was 4 mm on the CR images with temporal subtraction and 6 mm on those without. Our results indicated that the subtraction images clearly improved the visibility of simulated nodules. (author)

  18. Pediatric head and neck lesions: assessment of vascularity by MR digital subtraction angiography.

    Science.gov (United States)

    Chooi, Weng Kong; Woodhouse, Neil; Coley, Stuart C; Griffiths, Paul D

    2004-08-01

    Pediatric head and neck lesions can be difficult to characterize on clinical grounds alone. We investigated the use of dynamic MR digital subtraction angiography as a noninvasive adjunct for the assessment of the vascularity of these abnormalities. Twelve patients (age range, 2 days to 16 years) with known or suspected vascular abnormalities were studied. Routine MR imaging, time-of-flight MR angiography, and MR digital subtraction angiography were performed in all patients. The dynamic sequence was acquired in two planes at one frame per second by using a thick section (6-10 cm) selective radio-frequency spoiled fast gradient-echo sequence and an IV administered bolus of contrast material. The images were subtracted from a preliminary mask sequence and viewed as a video-inverted cine loop. In all cases, MR digital subtraction angiography was successfully performed. The technique showed the following: 1) slow flow lesions (two choroidal angiomas, eyelid hemangioma, and scalp venous malformation); 2) high flow lesions that were not always suspected by clinical examination alone (parotid hemangioma, scalp, occipital, and eyelid arteriovenous malformations plus a palatal teratoma); 3) a hypovascular tumor for which a biopsy could be safely performed (Burkitt lymphoma); and 4) a hypervascular tumor of the palate (cystic teratoma). Our early experience suggests that MR digital subtraction angiography can be reliably performed in children of all ages without complication. The technique provided a noninvasive assessment of the vascularity of each lesion that could not always have been predicted on the basis of clinical examination or routine MR imaging alone.

  19. Design of a High Linearity Four-Quadrant Analog Multiplier in Wideband Frequency Range

    Directory of Open Access Journals (Sweden)

    Abdul kareem Mokif Obais

    2017-05-01

    Full Text Available In this paper, a voltage mode four quadrant analog multiplier in the wideband frequency rangeis designed using a wideband operational amplifier (OPAMP and squaring circuits. The wideband OPAMP is designed using 10 identical NMOS transistorsand operated with supply voltages of ±12V. Two NMOS transistors and two wideband OPAMP are utilized in the design of the proposed squaring circuit. All the NMOS transistors are based on 0.35µm NMOStechnology. The multiplier has input and output voltage ranges of ±10 V, high range of linearity from -10 V to +10 V, and cutoff frequency of about 5 GHz. The proposed multiplier is designed on PSpice in Orcad 16.6

  20. Lagrange-multiplier tests for weak exogeneity: a synthesis.

    NARCIS (Netherlands)

    Boswijk, H.P.; Urbain, J.P.

    1997-01-01

    This paper unifies two seemingly separate approaches to test weak exogeneity in dynamic regression models with Lagrange-multiplier statistics. The first class of tests focuses on the orthogonality between innovations and conditioning variables, and thus is related to the Durbin-Wu-Hausman

  1. Big Bang Observer and the neutron-star-binary subtraction problem

    International Nuclear Information System (INIS)

    Cutler, Curt; Harms, Jan

    2006-01-01

    The Big Bang Observer (BBO) is a proposed space-based gravitational-wave (GW) mission designed primarily to search for an inflation-generated GW background in the frequency range ∼10 -1 Hz-1 Hz. The major astrophysical foreground in this range is gravitational radiation from inspiralling compact binaries. This foreground is expected to be much larger than the inflation-generated background, so to accomplish its main goal, BBO must be sensitive enough to identify and subtract out practically all such binaries in the observable universe. It is somewhat subtle to decide whether BBO's current baseline design is sufficiently sensitive for this task, since, at least initially, the dominant noise source impeding identification of any one binary is confusion noise from all the others (rather than instrumental noise). Here we present a self-consistent scheme for deciding whether BBO's baseline design is indeed adequate for subtracting out the binary foreground. We conclude that the current baseline should be sufficient. However, if BBO's sensitivity were degraded by a factor 2 from the current baseline, then its ability to detect an underlying primordial background would depend critically on the value of ρ th , the threshold signal-to-noise ratio marking the boundary between detectable and undetectable sources. If BBO's sensitivity were degraded by a factor 4 from the current baseline, it could not detect a primordial background below Ω GW ∼10 -15 . It is impossible to perfectly subtract out each of the binary inspiral waveforms, so an important question is how to deal with the 'residual' errors in the post-subtraction data stream. We sketch a strategy of 'projecting out' these residual errors, at the cost of some effective bandwidth. We also provide estimates of the sizes of various post-Newtonian effects in the inspiral waveforms that must be accounted for in the BBO analysis

  2. Digital subtraction in gadolinium-enhanced MR imaging of the brain: a method to reduce contrast dosage

    International Nuclear Information System (INIS)

    Chan, J.H.M.; Tsui, E.Y.K.; Chan, C.Y.; Lai, K.F.; Cheung, Y.K.; Wong, K.P.C.; Yuen, M.K.; Chau, L.F.; Fong, D.; Mok, C.K.

    2002-01-01

    The aim of the study was to investigate the feasibility of using digital subtraction in contrast-enhanced MR imaging of the brain to reduce the MR contrast dosage without jeopardizing patient care. Fifty-two patients with intracranial lesions, either intra-axial or extra-axial, detected by computerized tomography were selected for contrast-enhanced MR imaging with half-dose and full-dose of gadopentetate dimeglumine. The half-dose unsubtracted, full-dose unsubtracted, and half-dose subtracted MR images were visually assessed by counting the number of enhancing brain lesions in the images and quantitatively analyzed by computing their lesion contrast-to-background ratios (CBR). The visual conspicuity of the half-dose subtracted MR images was comparable to that of the full-dose unsubtracted MR images (p>0.05), whereas the CBR of the half-dose subtracted images was approximately two to three times higher than that of the full-dose unsubtracted images. The half-dose subtracted T1-weighted spin-echo images might be able to replace the conventional standard-dose T1-weighted spin-echo images in MR imaging of the brain. (orig.)

  3. [Development of a digital chest phantom for studies on energy subtraction techniques].

    Science.gov (United States)

    Hayashi, Norio; Taniguchi, Anna; Noto, Kimiya; Shimosegawa, Masayuki; Ogura, Toshihiro; Doi, Kunio

    2014-03-01

    Digital chest phantoms continue to play a significant role in optimizing imaging parameters for chest X-ray examinations. The purpose of this study was to develop a digital chest phantom for studies on energy subtraction techniques under ideal conditions without image noise. Computed tomography (CT) images from the LIDC (Lung Image Database Consortium) were employed to develop a digital chest phantom. The method consisted of the following four steps: 1) segmentation of the lung and bone regions on CT images; 2) creation of simulated nodules; 3) transformation to attenuation coefficient maps from the segmented images; and 4) projection from attenuation coefficient maps. To evaluate the usefulness of digital chest phantoms, we determined the contrast of the simulated nodules in projection images of the digital chest phantom using high and low X-ray energies, soft tissue images obtained by energy subtraction, and "gold standard" images of the soft tissues. Using our method, the lung and bone regions were segmented on the original CT images. The contrast of simulated nodules in soft tissue images obtained by energy subtraction closely matched that obtained using the gold standard images. We thus conclude that it is possible to carry out simulation studies based on energy subtraction techniques using the created digital chest phantoms. Our method is potentially useful for performing simulation studies for optimizing the imaging parameters in chest X-ray examinations.

  4. Jacobi's last multiplier and symmetries for the Kepler problem plus a lineal story

    International Nuclear Information System (INIS)

    Nucci, M C; Leach, P G L

    2004-01-01

    We calculate the first integrals of the Kepler problem by the method of Jacobi's last multiplier using the symmetries for the equations of motion. Also we provide another example which shows that Jacobi's last multiplier together with Lie symmetries unveils many first integrals neither necessarily algebraic nor rational whereas other published methods may yield just one

  5. Moving object detection using background subtraction

    CERN Document Server

    Shaikh, Soharab Hossain; Chaki, Nabendu

    2014-01-01

    This Springer Brief presents a comprehensive survey of the existing methodologies of background subtraction methods. It presents a framework for quantitative performance evaluation of different approaches and summarizes the public databases available for research purposes. This well-known methodology has applications in moving object detection from video captured with a stationery camera, separating foreground and background objects and object classification and recognition. The authors identify common challenges faced by researchers including gradual or sudden illumination change, dynamic bac

  6. Practical applications and methods in performing cardiac digital subtraction angiography

    International Nuclear Information System (INIS)

    Markovic, D.M.; Withrow, S.; Moodie, D.S.

    1986-01-01

    One of the purposes of this book is to outline the utility of digital subtraction angiography (DSA) in common clinical practice. No text has dealt with the actual physical setup of the room or the patient prior and during a digital subtraction angiographic study at rest and with exercise. This chapter outlines the steps commonly used when cardiac DSA is performed on patients in the authors' laboratory. The authors have learned over the last few years the best way to prepare the patient and the equipment and it is hoped that utilizing this experience, other centers may avoid the mistakes the authors have made in the past and develop new techniques for the future

  7. Safety analysis report for the Neutron Multiplier Facility, 329 Building

    International Nuclear Information System (INIS)

    Rieck, H.G.

    1978-09-01

    Neutron multiplication is a process wherein the flux of a neutron source such as 252 Cf is enhanced by fission reactions that occur in a subcritical assemblage of fissile material. The multiplication factor of the device depends upon the consequences of neutron reactions with matter and is independent of the initial number of neutrons present. Safe utilization of such a device demands that the fissile material assemblage be maintained in a subcritical state throughout all normal and credibly abnormal conditions. Examples of things that can alter the multiplication factor (and degree of subcriticality) are temperature fluctuations, changes in moderator material such as voiding or composition, addition of fissile materials, and change in assembly configuration. The Neutron Multiplier Facility (NMF) utilizes a multiplier- 252 Cf assembly to produce neutrons for activation analysis of organic and inorganic environmental samples and for on-line mass spectrometry analysis of fission products which diffuse from a stationary fissile target (less than or equal to 4 g fissile material) located in the Neutron Multiplier. The NMF annex to the 329 Building provides close proximity to related counting equipment, and delay between sample irradiation and counting is minimized

  8. The Uncertainty Multiplier and Business Cycles

    OpenAIRE

    Saijo, Hikaru

    2013-01-01

    I study a business cycle model where agents learn about the state of the economy by accumulating capital. During recessions, agents invest less, and this generates noisier estimates of macroeconomic conditions and an increase in uncertainty. The endogenous increase in aggregate uncertainty further reduces economic activity, which in turn leads to more uncertainty, and so on. Thus, through changes in uncertainty, learning gives rise to a multiplier effect that amplifies business cycles. I use ...

  9. Subtracted Dispersion Relations for In-medium Meson Correlators in QCD Sum Rules

    Energy Technology Data Exchange (ETDEWEB)

    Florkowski, W; Broniowski, W [The H. Niewodniczanski Institute of Nuclear Physics, Cracow (Poland)

    1999-01-01

    We analyze subtracted dispersion relations for meson correlators at finite baryon density and temperature. Such relations are needed for QCD sum rules. We point out that importance of scattering terms, as well as finite, well-defined subtraction constants. Both are necessary for consistency, in particular for the equality of the longitudinal and transverse correlators in the limit of the vanishing three-momentum of mesons relative to the medium. We present detailed calculations in various mesonic channels of the Fermi gas of nucleons. (author)

  10. A high reliability automatic multiplier for a mass spectrometer ion detector circuit

    International Nuclear Information System (INIS)

    Hoshino, Kiichi; Satooka, Sakae

    1978-01-01

    An automatic multiplier of an ion detector circuit for measurement of isotopic abundance ratio of heavy hydrogen to be used with a single collector has been constructed. This multiplier works at 1/1, 1/5, 1/20, 1/100, 1/500, 1/2000 and infinity, and the input voltage which is required to change the range from 1/1 to 1/5 is 10 mV and that from 1/2000 to infinity is 20 V. As the amplifier preceding the automatic multiplier, a vibrating reed electrometer which generates maximum output of 30 V is used. On measurement, marks which indicate the magnifications are recorded on the chart of electronic recorder. It is possible to set the minimum magnification at 1/1, 1/5, or 1/20 by a switch for setting the minimum magnification. (author)

  11. Higgs boson production in association with a jet using jettiness subtraction

    Directory of Open Access Journals (Sweden)

    Radja Boughezal

    2015-09-01

    Full Text Available We use the recently proposed jettiness-subtraction scheme to provide the complete calculation of Higgs boson production in association with a jet in hadronic collisions through next-to-next-to-leading order in perturbative QCD. This method exploits the observation that the N-jettiness event-shape variable completely describes the singularity structure of QCD when final-state colored particles are present. Our results are in agreement with a recent computation of the gg and qg partonic initial states based on sector-improved residue subtraction. We present phenomenological results for both fiducial cross sections and distributions at the LHC.

  12. Subtraction method of computing QCD jet cross sections at NNLO accuracy

    Science.gov (United States)

    Trócsányi, Zoltán; Somogyi, Gábor

    2008-10-01

    We present a general subtraction method for computing radiative corrections to QCD jet cross sections at next-to-next-to-leading order accuracy. The steps needed to set up this subtraction scheme are the same as those used in next-to-leading order computations. However, all steps need non-trivial modifications, which we implement such that that those can be defined at any order in perturbation theory. We give a status report of the implementation of the method to computing jet cross sections in electron-positron annihilation at the next-to-next-to-leading order accuracy.

  13. Subtraction method of computing QCD jet cross sections at NNLO accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Trocsanyi, Zoltan [University of Debrecen and Institute of Nuclear Research of the Hungarian Academy of Sciences, H-4001 Debrecen P.O.Box 51 (Hungary)], E-mail: Zoltan.Trocsanyi@cern.ch; Somogyi, Gabor [University of Zuerich, Winterthurerstrasse 190, CH-8057 Zuerich (Switzerland)], E-mail: sgabi@physik.unizh.ch

    2008-10-15

    We present a general subtraction method for computing radiative corrections to QCD jet cross sections at next-to-next-to-leading order accuracy. The steps needed to set up this subtraction scheme are the same as those used in next-to-leading order computations. However, all steps need non-trivial modifications, which we implement such that that those can be defined at any order in perturbation theory. We give a status report of the implementation of the method to computing jet cross sections in electron-positron annihilation at the next-to-next-to-leading order accuracy.

  14. Increasing Entanglement between Gaussian States by Coherent Photon Subtraction

    DEFF Research Database (Denmark)

    Ourjoumtsev, Alexei; Dantan, Aurelien Romain; Tualle Brouri, Rosa

    2007-01-01

    We experimentally demonstrate that the entanglement between Gaussian entangled states can be increased by non-Gaussian operations. Coherent subtraction of single photons from Gaussian quadrature-entangled light pulses, created by a nondegenerate parametric amplifier, produces delocalized states...

  15. Atomic collisions in fusion plasmas involving multiply charged ions

    International Nuclear Information System (INIS)

    Salzborn, E.

    1980-01-01

    A short survey is given on atomic collisions involving multiply charged ions. The basic features of charge transfer processes in ion-ion and ion-atom collisions relevant to fusion plasmas are discussed. (author)

  16. Improvement of temporal and dynamic subtraction images on abdominal CT using 3D global image matching and nonlinear image warping techniques

    International Nuclear Information System (INIS)

    Okumura, E; Sanada, S; Suzuki, M; Takemura, A; Matsui, O

    2007-01-01

    Accurate registration of the corresponding non-enhanced and arterial-phase CT images is necessary to create temporal and dynamic subtraction images for the enhancement of subtle abnormalities. However, respiratory movement causes misregistration at the periphery of the liver. To reduce these misregistration errors, we developed a temporal and dynamic subtraction technique to enhance small HCC by 3D global matching and nonlinear image warping techniques. The study population consisted of 21 patients with HCC. Using the 3D global matching and nonlinear image warping technique, we registered current and previous arterial-phase CT images or current non-enhanced and arterial-phase CT images obtained in the same position. The temporal subtraction image was obtained by subtracting the previous arterial-phase CT image from the warped current arterial-phase CT image. The dynamic subtraction image was obtained by the subtraction of the current non-enhanced CT image from the warped current arterial-phase CT image. The percentage of fair or superior temporal subtraction images increased from 52.4% to 95.2% using the new technique, while on the dynamic subtraction images, the percentage increased from 66.6% to 95.2%. The new subtraction technique may facilitate the diagnosis of subtle HCC based on the superior ability of these subtraction images to show nodular and/or ring enhancement

  17. Energy and intensity distributions of 0.279 MeV multiply Compton-scattered photons in soldering material

    International Nuclear Information System (INIS)

    Singh, Manpreet; Singh, Gurvinderjit; Singh, Bhajan; Sandhu, B.S.

    2007-01-01

    An inverse response matrix converts the observed pulse-height distribution of a NaI(Tl) scintillation detector to a photon spectrum. This also results in extraction of intensity distribution of multiply scattered events originating from interactions of 0.279 MeV photons with thick targets of soldering material. The observed pulse-height distributions are a composite of singly and multiply scattered events in addition to bremmstrahlung-and Rayleigh-scattered events. To evaluate the contribution of multiply scattered events, the spectrum of singly scattered events contributing to inelastic Compton peak is reconstructed analytically. The optimum thickness (saturation depth), at which the number of multiply scattered events saturates, has been measured. Monte Carlo calculations also support the present results

  18. Multivariate spatial condition mapping using subtractive fuzzy cluster means.

    Science.gov (United States)

    Sabit, Hakilo; Al-Anbuky, Adnan

    2014-10-13

    Wireless sensor networks are usually deployed for monitoring given physical phenomena taking place in a specific space and over a specific duration of time. The spatio-temporal distribution of these phenomena often correlates to certain physical events. To appropriately characterise these events-phenomena relationships over a given space for a given time frame, we require continuous monitoring of the conditions. WSNs are perfectly suited for these tasks, due to their inherent robustness. This paper presents a subtractive fuzzy cluster means algorithm and its application in data stream mining for wireless sensor systems over a cloud-computing-like architecture, which we call sensor cloud data stream mining. Benchmarking on standard mining algorithms, the k-means and the FCM algorithms, we have demonstrated that the subtractive fuzzy cluster means model can perform high quality distributed data stream mining tasks comparable to centralised data stream mining.

  19. New electronic filtering technique in digital subtraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Stacul, F; Pozzi-Mucelli, R; Predonzan, F; Magnaldi, S; Godina, G

    1986-01-01

    The authors report their experience with a new electronic filtering technique in digital subtraction angiography (DSA). The principles of the technique are reported and the advantages in comparison with conventional filters are stressed (accurate and fast placement without fluoroscopic exposure). The system provided excellent results in about 900 DSA examinations.

  20. Proposal for electro-optic multiplier based on dual transverse electro-optic Kerr effect.

    Science.gov (United States)

    Li, Changsheng

    2008-10-20

    A novel electro-optic multiplier is proposed, which can perform voltage multiplication operation by use of the Kerr medium exhibiting dual transverse electro-optic Kerr effect. In this kind of Kerr medium, electro-optic phase retardation is proportional to the square of its applied electric field, and orientations of the field-induced birefringent axes are only related to the direction of the field. Based on this effect, we can design an electro-optic multiplier by selecting the crystals of 6/mmm, 432, and m3m classes and isotropic Kerr media such as glass. Simple calculation demonstrates that a kind of glass-ceramic material with a large Kerr constant can be used for the design of the proposed electro-optic multiplier.

  1. Garbage-free reversible constant multipliers for arbitrary integers

    DEFF Research Database (Denmark)

    Mogensen, Torben Ægidius

    2013-01-01

    We present a method for constructing reversible circuitry for multiplying integers by arbitrary integer constants. The method is based on Mealy machines and gives circuits whose size are (in the worst case) linear in the size of the constant. This makes the method unsuitable for large constants...

  2. NNLO jet cross sections by subtraction

    International Nuclear Information System (INIS)

    Somogyi, G.; Bolzoni, P.; Trocsanyi, Z.

    2010-06-01

    We report on the computation of a class of integrals that appear when integrating the so-called iterated singly-unresolved approximate cross section of an earlier NNLO subtraction scheme over the factorised phase space of unresolved partons. The integrated approximate cross section itself can be written as the product of an insertion operator (in colour space) times the Born cross section. We give selected results for the insertion operator for processes with two and three hard partons in the final state. (orig.)

  3. NNLO jet cross sections by subtraction

    Energy Technology Data Exchange (ETDEWEB)

    Somogyi, G.; Bolzoni, P. [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany); Trocsanyi, Z. [CERN, Geneva (Switzerland)

    2010-06-15

    We report on the computation of a class of integrals that appear when integrating the so-called iterated singly-unresolved approximate cross section of an earlier NNLO subtraction scheme over the factorised phase space of unresolved partons. The integrated approximate cross section itself can be written as the product of an insertion operator (in colour space) times the Born cross section. We give selected results for the insertion operator for processes with two and three hard partons in the final state. (orig.)

  4. NNLO jet cross sections by subtraction

    CERN Document Server

    Somogyi, Gabor; Trocsanyi, Zoltan

    2010-01-01

    We report on the computation of a class of integrals that appear when integrating the so-called iterated singly-unresolved approximate cross section of the NNLO subtraction scheme of [1-4], over the factorised phase space of unresolved partons. The integrated approximate cross section itself can be written as the product of an insertion operator (in colour space) times the Born cross section. We give selected results for the insertion operator for processes with two and three hard partons in the final state.

  5. Image restorations constrained by a multiply exposed picture

    International Nuclear Information System (INIS)

    Breedlove, J.R. Jr.; Kruger, R.P.; Trussell, H.J.; Hunt, B.R.

    1977-01-01

    There are a number of possible industrial and scientific applications of nanosecond cineradiographs. While the technology exists to produce closely spaced pulses of x rays for this application, the quality of the time-resolved radiographs is severely limited. The limitations arise from the necessity of using a fluorescent screen to convert the transmitted x rays to light and then using electro-optical imaging systems to gate and to record the images with conventional high-speed cameras. It has been proposed that in addition to the time-resolved images, a conventional multiply-exposed radiograph be obtained. Simulations are used to demonstrate that the additional information supplied by the multiply-exposed radiograph can be used to improve the quality of digital image restorations of the time-resolved pictures over what could be achieved with the degraded images alone. Because of the need for image registration and rubber sheet transformations, this problem is one which can best be solved on a digital, as opposed to an optical, computer

  6. Multiplier-free filters for wideband SAR

    DEFF Research Database (Denmark)

    Dall, Jørgen; Christensen, Erik Lintz

    2001-01-01

    This paper derives a set of parameters to be optimized when designing filters for digital demodulation and range prefiltering in SAR systems. Aiming at an implementation in field programmable gate arrays (FPGAs), an approach for the design of multiplier-free filters is outlined. Design results...... are presented in terms of filter complexity and performance. One filter has been coded in VHDL and preliminary results indicate that the filter can meet a 2 GHz input sample rate....

  7. Solution of second order linear fuzzy difference equation by Lagrange's multiplier method

    Directory of Open Access Journals (Sweden)

    Sankar Prasad Mondal

    2016-06-01

    Full Text Available In this paper we execute the solution procedure for second order linear fuzzy difference equation by Lagrange's multiplier method. In crisp sense the difference equation are easy to solve, but when we take in fuzzy sense it forms a system of difference equation which is not so easy to solve. By the help of Lagrange's multiplier we can solved it easily. The results are illustrated by two different numerical examples and followed by two applications.

  8. Digital subtraction angiography

    International Nuclear Information System (INIS)

    Gmelin, E.; Arlart, I.P.

    1987-01-01

    The introduction explains the technical and physical fundamentals of digital radiography, the principles of digital subtraction, and the various filtering methods. The authors then define the requirements to be met by a DSA equipment in terms of technical components and operational performance. A very extensive chapter deals with the indications supporting intravenous or intraarterial DSA and compares the two methods, showing advantages and drawbacks with respect to practical results. Another chapter discusses the applications of DSA for cardiological diagnostics, as e.g. imaging of the coronary arteries or arterial bypasses, and explains the densitometric and planimetric evaluation of the coronary functional processes. The book also discusses less customary applications of DSA such as the sialography or dacryocystography, as well as angiologic examinations in children. The limits of the DSA methods are discussed in the last chapter, together with aspects such as the radiation exposure of the patient, and cost-benefit analyses, and potential future improvements. With 204 figs., 44 tabs [de

  9. Design of Low Power Multiplier with Energy Efficient Full Adder Using DPTAAL

    Directory of Open Access Journals (Sweden)

    A. Kishore Kumar

    2013-01-01

    Full Text Available Asynchronous adiabatic logic (AAL is a novel lowpower design technique which combines the energy saving benefits of asynchronous systems with adiabatic benefits. In this paper, energy efficient full adder using double pass transistor with asynchronous adiabatic logic (DPTAAL is used to design a low power multiplier. Asynchronous adiabatic circuits are very low power circuits to preserve energy for reuse, which reduces the amount of energy drawn directly from the power supply. In this work, an 8×8 multiplier using DPTAAL is designed and simulated, which exhibits low power and reliable logical operations. To improve the circuit performance at reduced voltage level, double pass transistor logic (DPL is introduced. The power results of the proposed multiplier design are compared with the conventional CMOS implementation. Simulation results show significant improvement in power for clock rates ranging from 100 MHz to 300 MHz.

  10. DO PUBLIC AND PRIVATE DEBT LEVELS AFFECT THE SIZE OF FISCAL MULTIPLIERS?

    Directory of Open Access Journals (Sweden)

    Chairul Adi

    2017-09-01

    Full Text Available This paper investigates the effectiveness of fiscal policies – as measured by the impact and cumulative multipliers – and how they interact with public and private debt. Harnessing the moderated panel regression approach, based on the yearly data set of several economies during the period from 1996 to 2012, the analysis is focused on the impact of spending-and-revenue-based fiscal policies on economic growth and how these fiscal instruments interact with public and private indebtedness. The result of spending stimuli advocates the basic Keynesian theory. An increase in public expenditures contemporaneously generates a positive multiplier, of around 0.29 – 0.44 and around 0.45 – 0.58 during two years. Decomposing the expenditures into their elements, this paper documents a stronger impact from public investment than that from government purchases. On the other hand, the revenue stimuli seem to follow the Ricardian Equivalence Hypothesis (REH, arguing that current tax cuts are inconsequential. The impact and cumulative multipliers for this fiscal instrument have mixed results, ranging from -0.21 to 0.05 and -0.26 to 0.06, respectively. Moreover, no robust evidence is found to support the argument that government debt moderates the effectiveness of fiscal policies. The size of the multipliers for both spending and revenue policies remain constant with the level of public debt. On the other hand, private debt appears to show a statistically significant moderating effect on spending stimuli. Its impact on spending multipliers, however, is economically insignificant. The moderation effect of private debt on the revenue stimuli does not seem to exist. Finally, this paper documents that both public and private debt exhibit a negative and statistically significant estimation for economic output.

  11. The Gas Electron Multiplier Chamber Exhibition LEPFest 2000

    CERN Multimedia

    2000-01-01

    The Gas Electron Multiplier (GEM) is a novel device introduced in 1996.Large area detectors based on this technology are in construction for high energy physics detectors.This technology can also be used for high-rate X-ray imaging in medical diagnostics and for monitoring irradiation during cancer treatment

  12. Comparison of iodine K-edge subtraction and fluorescence subtraction imaging in an animal system

    International Nuclear Information System (INIS)

    Zhang, H.; Zhu, Y.; Bewer, B.; Zhang, L.; Korbas, M.; Pickering, I.J.; George, G.N.; Gupta, M.; Chapman, D.

    2008-01-01

    K-Edge Subtraction (KES) utilizes the discontinuity in the X-ray absorption across the absorption edge of the selected contrast element and creates an image of the projected density of the contrast element from two images acquired just above and below the K-edge of the contrast element. KES has proved to be powerful in coronary angiography, micro-angiography, bronchography, and lymphatic imaging. X-ray fluorescence imaging is a successful technique for the detection of dilute quantities of elements in specimens. However, its application at high X-ray energies (e.g. at the iodine K-edge) is complicated by significant Compton background, which may enter the energy window set for the contrast material's fluorescent X-rays. Inspired by KES, Fluorescence Subtraction Imaging (FSI) is a technique for high-energy (>20 keV) fluorescence imaging using two different incident beam energies just above and below the absorption edge of a contrast element (e.g. iodine). The below-edge image can be assumed as a 'background' image, which includes Compton scatter and fluorescence from other elements. The above-edge image will contain nearly identical spectral content as the below-edge image but will contain the additional fluorescence of the contrast element. This imaging method is especially promising with thick objects with dilute contrast materials, significant Compton background, and/or competing fluorescence lines from other materials. A quality factor is developed to facilitate the comparison. The theoretical value of the quality factor sets the upper limit that an imaging method can achieve when the noise is Poisson limited. The measured value of this factor makes two or more imaging methods comparable. Using the Hard X-ray Micro-Analysis (HXMA) beamline at the Canadian Light Source (CLS), the techniques of FSI and KES were critically compared, with reference to radiation dose, image acquisition time, resolution, signal-to-noise ratios, and quality factor

  13. Auditing the multiply-related concepts within the UMLS.

    Science.gov (United States)

    Mougin, Fleur; Grabar, Natalia

    2014-10-01

    This work focuses on multiply-related Unified Medical Language System (UMLS) concepts, that is, concepts associated through multiple relations. The relations involved in such situations are audited to determine whether they are provided by source vocabularies or result from the integration of these vocabularies within the UMLS. We study the compatibility of the multiple relations which associate the concepts under investigation and try to explain the reason why they co-occur. Towards this end, we analyze the relations both at the concept and term levels. In addition, we randomly select 288 concepts associated through contradictory relations and manually analyze them. At the UMLS scale, only 0.7% of combinations of relations are contradictory, while homogeneous combinations are observed in one-third of situations. At the scale of source vocabularies, one-third do not contain more than one relation between the concepts under investigation. Among the remaining source vocabularies, seven of them mainly present multiple non-homogeneous relations between terms. Analysis at the term level also shows that only in a quarter of cases are the source vocabularies responsible for the presence of multiply-related concepts in the UMLS. These results are available at: http://www.isped.u-bordeaux2.fr/ArticleJAMIA/results_multiply_related_concepts.aspx. Manual analysis was useful to explain the conceptualization difference in relations between terms across source vocabularies. The exploitation of source relations was helpful for understanding why some source vocabularies describe multiple relations between a given pair of terms. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  14. A Feature Subtraction Method for Image Based Kinship Verification under Uncontrolled Environments

    DEFF Research Database (Denmark)

    Duan, Xiaodong; Tan, Zheng-Hua

    2015-01-01

    The most fundamental problem of local feature based kinship verification methods is that a local feature can capture the variations of environmental conditions and the differences between two persons having a kin relation, which can significantly decrease the performance. To address this problem...... the feature distance between face image pairs with kinship and maximize the distance between non-kinship pairs. Based on the subtracted feature, the verification is realized through a simple Gaussian based distance comparison method. Experiments on two public databases show that the feature subtraction method...

  15. Clinical usefulness of subtraction scintigraphy of the liver with Ga-67-citrate and Tc-99m-colloid

    International Nuclear Information System (INIS)

    Oyamada, H.; Terui, S.; Nagaiwa, K.; Kawai, H.; Fukukita, H.

    1983-01-01

    Subtraction scintigraphy of the liver with Ga-67-citrate and Tc-99m-colloid was performed for the radionuclide image diagnosis of intrahepatic masses, especially hepatoma. In this method the Tc-99m image was subtracted from the Ga-67 image. After normalizing both images, 4 different factors (0.6, 0.8, 1.0, and 1.2) were applied to the Tc-99m image before the subtraction. Finally, 4 subtraction images with different contrasts were obtained in one X-ray film. This method was found to be very useful in the assessment of intrahepatic focal accumulation of Ga-67, especially in cases with hepatoma, because it eliminated the uncertainty in the former method in which only visual judgment was done

  16. Speech Enhancement by Multichannel Crosstalk Resistant ANC and Improved Spectrum Subtraction

    Directory of Open Access Journals (Sweden)

    Zeng Qingning

    2006-01-01

    Full Text Available A scheme combining multichannel crosstalk resistant adaptive noise cancellation (MCRANC algorithm and improved spectrum subtraction (ISS algorithm is presented to enhance noise carrying speech signals. The scheme would permit locating the microphones in close proximity by virtue of using MCRANC which has the capability of removing the crosstalk effect. MCRANC would also permit canceling out nonstationary noise and making the residual noise more stationary for further treatment by ISS algorithm. Experimental results have indicated that this scheme outperforms many commonly used techniques in the sense of SNR improvement and music effect reduction which is an inevitable byproduct of the spectrum subtraction algorithm.

  17. Quantum mechanics in a multiply connected region

    International Nuclear Information System (INIS)

    Miyazawa, H.

    1986-01-01

    It is usually assumed that wave fields or wave functions are single valued functions of space-time. However, the phase of a complex field is an unobservable quantity and there is no obvious reason that it must be single valued. On this point quantum mechanics in a multiply connected regions is not well formulated. This ambiguity appears e.g., in the case of the Bohm-Aharonov effect concerning the observability of the vector potential around a magnetic flux. The author discusses the single or multiple valuedness of wave functions and attempts to see if such an effect really exists or not. The wave function of a charged particle in a multiply connected region is not necessarily single valued. The condition that the ground state energy be a minimum fixes the character of the multiple valuedness. For a charged particle around a magnetic flux a multiple valued wave function is preferable and no Bohm-Aharonov effect is observed. The minimum energy principle is proved if one also considers the interaction of a charged particle with external objects. Then theoretically the Bohm-Aharonov effect should not be observed. Experiments are not yet conclusive on this point

  18. Charge amplification and transfer processes in the gas electron multiplier

    International Nuclear Information System (INIS)

    Bachmann, S.; Bressan, A.; Ropelewski, L.; Sauli, F.; Sharma, A.; Moermann, D.

    1999-01-01

    We report the results of systematic investigations on the operating properties of detectors based on the gas electron multiplier (GEM). The dependence of gain and charge collection efficiency on the external fields has been studied in a range of values for the hole diameter and pitch. The collection efficiency of ionization electrons into the multiplier, after an initial increase, reaches a plateau extending to higher values of drift field the larger the GEM voltage and its optical transparency. The effective gain, fraction of electrons collected by an electrode following the multiplier, increases almost linearly with the collection field, until entering a steeper parallel plate multiplication regime. The maximum effective gain attainable increases with the reduction in the hole diameter, stabilizing to a constant value at a diameter approximately corresponding to the foil thickness. Charge transfer properties appear to depend only on ratios of fields outside and within the channels, with no interaction between the external fields. With proper design, GEM detectors can be optimized to satisfy a wide range of experimental requirements: tracking of minimum ionizing particles, good electron collection with small distortions in high magnetic fields, improved multi-track resolution and strong ion feedback suppression in large volume and time-projection chambers

  19. Effects of global signal regression and subtraction methods on resting-state functional connectivity using arterial spin labeling data.

    Science.gov (United States)

    Silva, João Paulo Santos; Mônaco, Luciana da Mata; Paschoal, André Monteiro; Oliveira, Ícaro Agenor Ferreira de; Leoni, Renata Ferranti

    2018-05-16

    Arterial spin labeling (ASL) is an established magnetic resonance imaging (MRI) technique that is finding broader applications in functional studies of the healthy and diseased brain. To promote improvement in cerebral blood flow (CBF) signal specificity, many algorithms and imaging procedures, such as subtraction methods, were proposed to eliminate or, at least, minimize noise sources. Therefore, this study addressed the main considerations of how CBF functional connectivity (FC) is changed, regarding resting brain network (RBN) identification and correlations between regions of interest (ROI), by different subtraction methods and removal of residual motion artifacts and global signal fluctuations (RMAGSF). Twenty young healthy participants (13 M/7F, mean age = 25 ± 3 years) underwent an MRI protocol with a pseudo-continuous ASL (pCASL) sequence. Perfusion-based images were obtained using simple, sinc and running subtraction. RMAGSF removal was applied to all CBF time series. Independent Component Analysis (ICA) was used for RBN identification, while Pearson' correlation was performed for ROI-based FC analysis. Temporal signal-to-noise ratio (tSNR) was higher in CBF maps obtained by sinc subtraction, although RMAGSF removal had a significant effect on maps obtained with simple and running subtractions. Neither the subtraction method nor the RMAGSF removal directly affected the identification of RBNs. However, the number of correlated and anti-correlated voxels varied for different subtraction and filtering methods. In an ROI-to-ROI level, changes were prominent in FC values and their statistical significance. Our study showed that both RMAGSF filtering and subtraction method might influence resting-state FC results, especially in an ROI level, consequently affecting FC analysis and its interpretation. Taking our results and the whole discussion together, we understand that for an exploratory assessment of the brain, one could avoid removing RMAGSF to

  20. Simultaneous optical digital half-subtraction and -addition using SOAs and a PPLN waveguide.

    Science.gov (United States)

    McGeehan, John E; Kumar, Saurabh; Willner, Alan E

    2007-04-30

    We demonstrate an optical half-subtracter and half-adder module that performs simultaneous bit-wise subtraction and addition of two 5 Gbit/s RZ data streams. We generate Borrow (/X*Y) and Difference/Sum (X plus sign in circleY, or XOR) outputs using cross-gain modulation (XGM) in two parallel SOAs. Taking advantage of the gain saturation inherent to SOAs, we generate two signals, /X*Y, and X*/Y, and combine them using a passive optical coupler to generate the XOR Difference/Sum output. We use difference-frequency-generation-based lambda-conversion in a PPLN waveguide to generate the Carry (X*Y) output. The PPLN waveguide allows bit-synchronous wavelength shifting, is wide-bandwidth, and offers no intrinsic chirp. Our module uses three active elements to perform simultaneous half-subtraction and addition, and carries a maximum power penalty of 1.0 dB.

  1. Electron cyclotron resonance multiply charged ion sources

    International Nuclear Information System (INIS)

    Geller, R.

    1975-01-01

    Three ion sources, that deliver multiply charged ion beams are described. All of them are E.C.R. ion sources and are characterized by the fact that the electrons are emitted by the plasma itself and are accelerated to the adequate energy through electron cyclotron resonance (E.C.R.). They can work without interruption during several months in a quasi-continuous regime. (Duty cycle: [fr

  2. Improved detection of pulmonary nodules on energy-subtracted chest radiographs with a commercial computer-aided diagnosis software: comparison with human observers

    International Nuclear Information System (INIS)

    Szucs-Farkas, Zsolt; Patak, Michael A.; Yuksel-Hatz, Seyran; Ruder, Thomas; Vock, Peter

    2010-01-01

    To retrospectively analyze the performance of a commercial computer-aided diagnosis (CAD) software in the detection of pulmonary nodules in original and energy-subtracted (ES) chest radiographs. Original and ES chest radiographs of 58 patients with 105 pulmonary nodules measuring 5-30 mm and images of 25 control subjects with no nodules were randomized. Five blinded readers evaluated firstly the original postero-anterior images alone and then together with the subtracted radiographs. In a second phase, original and ES images were analyzed by a commercial CAD program. CT was used as reference standard. CAD results were compared to the readers' findings. True-positive (TP) and false-positive (FP) findings with CAD on subtracted and non-subtracted images were compared. Depending on the reader's experience, CAD detected between 11 and 21 nodules missed by readers. Human observers found three to 16 lesions missed by the CAD software. CAD used with ES images produced significantly fewer FPs than with non-subtracted images: 1.75 and 2.14 FPs per image, respectively (p=0.029). The difference for the TP nodules was not significant (40 nodules on ES images and 34 lesions in non-subtracted radiographs, p = 0.142). CAD can improve lesion detection both on energy subtracted and non-subtracted chest images, especially for less experienced readers. The CAD program marked less FPs on energy-subtracted images than on original chest radiographs. (orig.)

  3. Design, implementation and performance comparison of multiplier topologies in power-delay space

    Directory of Open Access Journals (Sweden)

    Mansi Jhamb

    2016-03-01

    Full Text Available With the advancements in the semiconductor industry, designing a high performance processor is a prime concern. Multiplier is one of the most crucial parts in almost every digital signal processing applications. This paper addresses the implementation of an 8-bit multiplier design employing CMOS full adder, full adder using Double Pass Transistor (DPL and multioutput carry Lookahead logic (CLA. DPL adder avoids the noise margin problem and speed degradation at low value of supply voltages associated with complementary pass transistor (CPL logic circuits. Multioutput carry lookahead adder leads to significant improvement in the speed of the overall circuitry. The investigation is carried out with simulation runs on HSPICE environment using 90 nm process technology at 25 °C. Finally, the design guidelines are derived to select the most suitable topology for the desired applications. Investigation reveals that multiplier design using multioutput carry lookahead adder proves to be more speed efficient in comparison with the other two considered design strategies.

  4. Formation of molecules in interstellar clouds from singly and multiply ionized atoms

    International Nuclear Information System (INIS)

    Langer, W.D.; and NASA, Institute for Space Studies, Goddard Space Flight Center, New York)

    1978-01-01

    Soft X-ray and cosmic rays produce multiply ionized atoms which may initiate molecule production in interstellar clouds. This molecule production can occur via ion-molecule reactions with H 2 , either directly from the multiply ionized atom (e.g.,C ++ + H 2 →CH + + H + ), or indirectly from the singly ionized atoms (e.g., N + + H 2 →NH + + H) that are formed from the recombination or charge transfer of the highly ionized atom (e.g., N ++ + e→N + + hv). We investigate the contribution of these reactions to the abundances of carbon-, nitrogen-, and oxygen-bearing molecules in isobaric models of diffuse clouds. In the presence of the average flux estimated for the diffuse soft X-ray background, multiply ionized atoms contribute only minimally (a few percent) to carbon-bearing molecules such as CH. In the neighborhood of diffuse structures or discrete sources, however, where the X-ray flux is enhanced, multiple ionization is considerably more important for molecule production

  5. Lower-Order Compensation Chain Threshold-Reduction Technique for Multi-Stage Voltage Multipliers.

    Science.gov (United States)

    Dell' Anna, Francesco; Dong, Tao; Li, Ping; Wen, Yumei; Azadmehr, Mehdi; Casu, Mario; Berg, Yngvar

    2018-04-17

    This paper presents a novel threshold-compensation technique for multi-stage voltage multipliers employed in low power applications such as passive and autonomous wireless sensing nodes (WSNs) powered by energy harvesters. The proposed threshold-reduction technique enables a topological design methodology which, through an optimum control of the trade-off among transistor conductivity and leakage losses, is aimed at maximizing the voltage conversion efficiency (VCE) for a given ac input signal and physical chip area occupation. The conducted simulations positively assert the validity of the proposed design methodology, emphasizing the exploitable design space yielded by the transistor connection scheme in the voltage multiplier chain. An experimental validation and comparison of threshold-compensation techniques was performed, adopting 2N5247 N-channel junction field effect transistors (JFETs) for the realization of the voltage multiplier prototypes. The attained measurements clearly support the effectiveness of the proposed threshold-reduction approach, which can significantly reduce the chip area occupation for a given target output performance and ac input signal.

  6. Can approximate mental calculation account for operational momentum in addition and subtraction?

    Science.gov (United States)

    Knops, André; Dehaene, Stanislas; Berteletti, Ilaria; Zorzi, Marco

    2014-01-01

    The operational momentum (OM) effect describes a cognitive bias whereby we overestimate the results of mental addition problems while underestimating for subtraction. To test whether the OM emerges from psychophysical characteristics of the mental magnitude representation we measured two basic parameters (Weber fraction and numerical estimation accuracy) characterizing the mental magnitude representation and participants' performance in cross-notational addition and subtraction problems. Although participants were able to solve the cross-notational problems, they consistently chose relatively larger results in addition problems than in subtraction problems, thus replicating and extending previous results. Combining the above measures in a psychophysical model allowed us to partially predict the chosen results. Most crucially, however, we were not able to fully model the OM bias on the basis of these psychophysical parameters. Our results speak against the idea that the OM is due to basic characteristics of the mental magnitude representation. In turn, this might be interpreted as evidence for the assumption that the OM effect is better explained by attentional shifts along the mental magnitude representation during mental calculation.

  7. Detection of aneurysms in subarachnoidal hemorrhage - CT-angiography versus digital subtraction angiography

    International Nuclear Information System (INIS)

    Roehnert, W.; Haenig, V.; Hietschold, V.; Abolmaali, N.

    1998-01-01

    Purpose: The value of CT-angiography (CT-A) for the visualization of intracranial aneurysms was more closely defined by comparison with digital subtraction angiography (DSA). Methods: Over a period of 18 months a total of 106 patients in whom a subarachnoidal hemorrhage had been detected on native CT were examined in parallel by spiral CT and DSA. CT-angiography was performed under standardized parameters and included processing with 3D surface reconstructions. Results: In 64 patients (60.4%) at total of 72 aneurysms were detected. In four cases (6.2%) there were two and in two cases (3.1%) even three aneurysms. The findings of DSA and CTA agreed in 98 cases (92.5%). In four patients (3.8%) a false negative results was obtained in CTA and the initial DSA. Conclusions: Digital subtraction angiography must still be considered as the gold standard in the diagnosis of cerebral aneurysms. On account of its excellent spatial delineation of aneurysms and possibilities for exact measurements, CT-angiography represents a valuable, supplementary method - in some cases also an alternative method - to digital subtraction angiography. (orig.) [de

  8. Children's Understanding of the Addition/Subtraction Complement Principle

    Science.gov (United States)

    Torbeyns, Joke; Peters, Greet; De Smedt, Bert; Ghesquière, Pol; Verschaffel, Lieven

    2016-01-01

    Background: In the last decades, children's understanding of mathematical principles has become an important research topic. Different from the commutativity and inversion principles, only few studies have focused on children's understanding of the addition/subtraction complement principle (if a - b = c, then c + b = a), mainly relying on verbal…

  9. Visualization of the renal venous system by renal arteriography with digital subtraction angiography

    International Nuclear Information System (INIS)

    Nagai, Jun

    1989-01-01

    The purpose of this study was to obtain vivid and precise images of intrarenal venous branching using DSA for renal arteriography. The type of system used was an ADAC DPS-4100C with 70-80 kVp, and 320 mA, 25-50 msec at 6 frames/sec. The duration was 10 sec and the matrix size was 512x512. In order to retain clear subtracted images of intrarenal venous branching with minimal noise the three frames were selected on the time-density curve of DSA: (Fig.3). 1) a frame on which renal arteries disappear (frame X), 2) the frame with highest renal venous density value as (frame Y), 3) the difference of the nephrogram density between X and Y frames in which only the density of the nephrogram decreases (frame Z). The mask image is the image subtracted by the equation of the weighted averaging method on X and Z frame and is subtracted from the image of Y frame in the final step. By this method, 40 kidneys in 36 patients were studied, and the intrarenal venous branches up to the interlobar vein was clearly demonstrated in 28 of these cases (70%). This method is useful to estimate the extent of intrarenal lesions and detect abnormal renal blood flow compared with conventional temporal subtraction method. (author)

  10. The role of contrast-enhanced digital subtraction MRI in the diagnosis of vertebral metastasic tumors

    International Nuclear Information System (INIS)

    Xiao Yeyu; Yang Jun; Qi Weili; Liu Qize; Hong Bikai; Wu Renhua

    2008-01-01

    Objective: To evaluate the contrast-enhanced digital subtraction MRI in the diagnosis of vertebral metastasic tumors. Methods 66 vertebral metastasic tumors in 43 patients were examined with conventional MRI (T 1 WI, STIR and Contrast-enhanced T 1 WI) and contrast-enhanced digital subtraction MR imaging. All lesions were histologically proved. The quantity and characteristic imaging signs (including spiculation, bull eye sign and irregular edge) of lesions were detected separately by different sequences. K independent samples test was used. Results: The detection rates of 35 vertebral metastasic tumors with vertebral morphological changes were same in all MR sequences. But in the other 31 lesions without vertebral morphological changes, the detection rates were different and STIR was the highest in all sequences. Contrast-enhanced digital subtraction MRI was more sensitive than all the conventional MR sequences in finding characteristic imaging signs with statistically significant differences. Conclusion: Contrast enhanced subtraction MRI is an useful and convenient technique which has great value in finding vertebral metastasic tumors and depicting the characteristic imaging signs. (authors)

  11. Magnetization transfer contrast (MTC) and MTC-subtraction: enhancement of cartilage lesions and intracartilaginous degeneration in vitro

    International Nuclear Information System (INIS)

    Vahlensieck, M.; Dombrowski, F.; Leutner, C.; Wagner, U.; Reiser, M.

    1994-01-01

    Human articular cartilage from 16 cadaveric or amputated knees was studied using standard magnetic resonance imaging (MRI), on-resonance magnetization transfer contrast (MTC) and MTC-subtraction MRI. Results were compared with subsequent macroscopic and histopathological findings. MTC-subtraction and T2-weighted spin-echo images visualized cartilaginous surface defects with high sensitivity and specificity. MTC and T2-weighted spin-echo images revealed intra-cartilaginous signal loss without surface defects in 80% of the cases, corresponding to an increased collagen concentration. It is concluded that MTC is sensitive to early cartilage degeneration and MTC-subtraction can be helpful in detecting cartilage defects. (orig.)

  12. Evaluation of the pulmonary vascular bed by digital subtraction angiography

    International Nuclear Information System (INIS)

    Shikuwa, Masahiro; Asai, Sadahiro; Hara, Shiro; Yamasa, Toshihiko; Miyahara, Yoshiyuki; Hara, Kohei; Nishijima, Kyoji.

    1995-01-01

    We studied the usefulness of digital subtraction angiography for evaluating the pulmonary capillary bed. Four individuals underwent the procedure. One was a healthy volunteer and the others were patients with chronic pulmonary emphysema. During catheterization, an 8 F balloon catheter was manipulated into the right pulmonary artery. A total of 20 ml of contrast material was injected at a rate of 10 ml/sec at full inspiration. In the normal subject, the capillary bed filled homogeneously and no defect was seen. In the patients, the pulmonary artery was nearly normal, but severe defects were observed in the pulmonary capillaries. Contrast resolvability was greater with digital subtraction pulmonary angiography than with pulmonary perfusion scintigraphy or pulmonary arteriography. This technique makes possible the visual evaluation of the pulmonary capillary bed. (author)

  13. Composite Field Multiplier based on Look-Up Table for Elliptic Curve Cryptography Implementation

    Directory of Open Access Journals (Sweden)

    Marisa W. Paryasto

    2012-04-01

    Full Text Available Implementing a secure cryptosystem requires operations involving hundreds of bits. One of the most recommended algorithm is Elliptic Curve Cryptography (ECC. The complexity of elliptic curve algorithms and parameters with hundreds of bits requires specific design and implementation strategy. The design architecture must be customized according to security requirement, available resources and parameter choices. In this work we propose the use of composite field to implement finite field multiplication for ECC implementation. We use 299-bit keylength represented in GF((21323 instead of in GF(2299. Composite field multiplier can be implemented using different multiplier for ground-field and for extension field. In this paper, LUT is used for multiplication in the ground-field and classic multiplieris used for the extension field multiplication. A generic architecture for the multiplier is presented. Implementation is done with VHDL with the target device Altera DE2. The work in this paper uses the simplest algorithm to confirm the idea that by dividing field into composite, use different multiplier for base and extension field would give better trade-off for time and area. This work will be the beginning of our more advanced further research that implements composite-field using Mastrovito Hybrid, KOA and LUT.

  14. Testing of money multiplier model for Pakistan: does monetary base carry any information?

    Directory of Open Access Journals (Sweden)

    Muhammad Arshad Khan

    2010-02-01

    Full Text Available This paper tests the constancy and stationarity of mechanic version of the money multiplier model for Pakistan using monthly data over the period 1972M1-2009M2. We split the data into pre-liberalization (1972M1-1990M12 and post-liberalization (1991M1-2009M2 periods to examine the impact of financial sector reforms. We first examine the constancy and stationarity of the money multiplier and the results suggest the money multiplier remains non-stationary for the entire sample period and sub-periods. We then tested cointegration between money supply and monetary base and find the evidence of cointegration between two variables for the entire period and two sub-periods. The coefficient restrictions are satisfied only for the post-liberalization period. Two-way long-run causality between money supply and monetary base is found for the entire period and post-liberalization. For the post-liberalization period the evidence of short-run causality running from monetary base to money supply is also identified. On the whole, the results suggest that money multiplier model can serve as framework for conducting short-run monetary policy in Pakistan. However, the monetary authority may consider the co-movements between money supply and reserve money at the time of conducting monetary policy.

  15. Composite Field Multiplier based on Look-Up Table for Elliptic Curve Cryptography Implementation

    Directory of Open Access Journals (Sweden)

    Marisa W. Paryasto

    2013-09-01

    Full Text Available Implementing a secure cryptosystem requires operations involving hundreds of bits. One of the most recommended algorithm is Elliptic Curve Cryptography (ECC. The complexity of elliptic curve algorithms and parameters with hundreds of bits requires specific design and implementation strategy. The design architecture must be customized according to security requirement, available resources and parameter choices. In this work we propose the use of composite field to implement finite field multiplication for ECC implementation. We use 299-bit keylength represented in GF((21323 instead of in GF(2299. Composite field multiplier can be implemented using different multiplier for ground-field and for extension field. In this paper, LUT is used for multiplication in the ground-field and classic multiplieris used for the extension field multiplication. A generic architecture for the multiplier is presented. Implementation is done with VHDL with the target device Altera DE2. The work in this paper uses the simplest algorithm to confirm the idea that by dividing field into composite, use different multiplier for base and extension field would give better trade-off for time and area. This work will be the beginning of our more advanced further research that implements composite-field using Mastrovito Hybrid, KOA and LUT.

  16. Evaluation of the utility of temporal subtraction images in successive whole-body bone scans: a prospective clinical study

    International Nuclear Information System (INIS)

    Shiraishi, J.; Appelbaum, D.; Pu, Y.; Engelmann, R.; Li Qiang; Doi, K.

    2007-01-01

    We have begun a prospective clinical study for evaluating the clinical utility of temporal subtraction images in successive whole-body bone scans. The computerized temporal subtraction technique has been developed in order to highlight interval changes of abnormal lesions due to skeletal metastases, primary bone tumors, osteomyelitis, and fractures. In our initial preliminary results of the prospective study which was started on November 22, 2006 in our hospital, radiologists reported some interval changes which were not recognized in the initial standard readings, but were obvious when temporal subtraction images were viewed. The usefulness of the temporal subtraction images will be investigated in terms of its clinical utility by the prospective clinical study. (orig.)

  17. Dynamic gadolinium-enhanced subtraction MR imaging - a simple technique for the early diagnosis of Legg-Calve-Perthes disease: preliminary results

    International Nuclear Information System (INIS)

    Sebag, G.; Ducou Le Pointe, H.; Klein, I.; Maiza, D.; Mazda, K.; Bensahel, H.; Hassan, M.

    1997-01-01

    To determine whether the simple technique of dynamic gadolinium-enhanced subtraction MR imaging, which is available on standard MR units, can detect ischemia of the femoral head in children with early Legg-Calve-Perthes disease (LCP). Bone perfusion of eight hips in four patients (mean age 7.5 years) was studied using dynamic gadolinium-enhanced substraction MR imaging at the onset of proven LCP (with initial negative plain films). Enhancement of subtracted images was compared with that on standard MR images and with bone scintigraphy findings. Subtraction MR imaging depicted ischemia as a widespread absence of enhancement and was in good agreement with bone scintigraphy. The subtraction technique improved the sensitivity and the specificity of MR imaging in two children. Furthermore, subtraction MR imaging allowed recognition of the pattern of early reperfusion. Our preliminary results indicate that dynamic gadolinium-enhanced subtraction MRI is a simple and promising means of early recognition of ischemia in LCP. (orig.)

  18. A multiple regression analysis for accurate background subtraction in 99Tcm-DTPA renography

    International Nuclear Information System (INIS)

    Middleton, G.W.; Thomson, W.H.; Davies, I.H.; Morgan, A.

    1989-01-01

    A technique for accurate background subtraction in 99 Tc m -DTPA renography is described. The technique is based on a multiple regression analysis of the renal curves and separate heart and soft tissue curves which together represent background activity. It is compared, in over 100 renograms, with a previously described linear regression technique. Results show that the method provides accurate background subtraction, even in very poorly functioning kidneys, thus enabling relative renal filtration and excretion to be accurately estimated. (author)

  19. Detection of pulmonary nodules on lung X-ray images. Studies on multi-resolutional filter and energy subtraction images

    International Nuclear Information System (INIS)

    Sawada, Akira; Sato, Yoshinobu; Kido, Shoji; Tamura, Shinichi

    1999-01-01

    The purpose of this work is to prove the effectiveness of an energy subtraction image for the detection of pulmonary nodules and the effectiveness of multi-resolutional filter on an energy subtraction image to detect pulmonary nodules. Also we study influential factors to the accuracy of detection of pulmonary nodules from viewpoints of types of images, types of digital filters and types of evaluation methods. As one type of images, we select an energy subtraction image, which removes bones such as ribs from the conventional X-ray image by utilizing the difference of X-ray absorption ratios at different energy between bones and soft tissue. Ribs and vessels are major causes of CAD errors in detection of pulmonary nodules and many researches have tried to solve this problem. So we select conventional X-ray images and energy subtraction X-ray images as types of images, and at the same time select ∇ 2 G (Laplacian of Guassian) filter, Min-DD (Minimum Directional Difference) filter and our multi-resolutional filter as types of digital filters. Also we select two evaluation methods and prove the effectiveness of an energy subtraction image, the effectiveness of Min-DD filter on a conventional X-ray image and the effectiveness of multi-resolutional filter on an energy subtraction image. (author)

  20. Relation between thallium-201/iodine 123-BMIPP subtraction and fluorine 18 deoxyglucose polar maps in patients with hypertrophic cardiomyopathy.

    Science.gov (United States)

    Ito, Y; Hasegawa, S; Yamaguchi, H; Yoshioka, J; Uehara, T; Nishimura, T

    2000-01-01

    Clinical studies have shown discrepancies in the distribution of thallium-201 and iodine 123-beta-methyl-iodophenylpentadecanoic acid (BMIPP) in patients with hypertrophic cardiomyopathy (HCM). Myocardial uptake of fluorine 18 deoxyglucose (FDG) is increased in the hypertrophic area in HCM. We examined whether the distribution of a Tl-201/BMIPP subtraction polar map correlates with that of an FDG polar map. We normalized to maximum count each Tl-201 and BMIPP bull's-eye polar map of 6 volunteers and obtained a standard Tl-201/BMIPP subtraction polar map by subtracting a normalized BMIPP bull's-eye polar map from a normalized Tl-201 bull's-eye polar map. The Tl-201/BMIPP subtraction polar map was then applied to 8 patients with HCM (mean age 65+/-12 years) to evaluate the discrepancy between Tl-201 and BMIPP distribution. We compared the Tl-201/BMIPP subtraction polar map with an FDG polar map. In patients with HCM, the Tl-201/BMIPP subtraction polar map showed a focal uptake pattern in the hypertrophic area similar to that of the FDG polar map. By quantitative analysis, the severity score of the Tl-201/BMIPP subtraction polar map was significantly correlated with the percent dose uptake of the FDG polar map. These results suggest that this new quantitative method may be an alternative to FDG positron emission tomography for the routine evaluation of HCM.

  1. Digital subtraction CT angiography for the detection of posterior inferior cerebellar artery aneurysms: comparison with digital subtraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Guo Zhong; Luo, Song; Zhou, Chang Sheng; Zhang, Long Jiang; Lu, Guang Ming [Jinling Hospital, Medical School of Nanjing University, Department of Medical Imaging, Nanjing, Jiangsu (China)

    2017-09-15

    To evaluate the diagnostic accuracy of digital subtraction CT angiography (DS-CTA) in detecting posterior inferior cerebellar artery (PICA) aneurysms with digital subtraction angiography (DSA) as reference standard. A total of 115 patients, including 56 patients diagnosed with PICA aneurysms by CTA or DSA and 59 non-PICA-aneurysm patients were included in this retrospective study. All patients underwent DS-CTA and DSA. The site of PICA aneurysms and the pattern of haemorrhage were analysed. Sensitivity and specificity of DS-CTA without and with combining haemorrhage pattern in diagnosing PICA aneurysms were evaluated on a per patient and per aneurysm basis with DSA. Of 115 patients, 56 patients (48.7%) had 61 PICA aneurysms (size range, 1.1-13.5 mm; mean size, 4.9 ± 2.8 mm) on DSA. The sensitivity and specificity in depicting PICA aneurysms were 89.3% and 96.6% on a per patient basis and 90.2% and 93.4% on a per aneurysm basis, while the corresponding values were 94.6% and 96.6% on a per patient basis and 95.1% and 93.4% on a per aneurysm basis when combining with haemorrhage site. DS-CTA has a high sensitivity and specificity in detecting PICA aneurysms compared with DSA. It may be helpful for clinical diagnosis of PICA aneurysms to combine with haemorrhage sites. (orig.)

  2. Deblurring in digital tomosynthesis by iterative self-layer subtraction

    Science.gov (United States)

    Youn, Hanbean; Kim, Jee Young; Jang, SunYoung; Cho, Min Kook; Cho, Seungryong; Kim, Ho Kyung

    2010-04-01

    Recent developments in large-area flat-panel detectors have made tomosynthesis technology revisited in multiplanar xray imaging. However, the typical shift-and-add (SAA) or backprojection reconstruction method is notably claimed by a lack of sharpness in the reconstructed images because of blur artifact which is the superposition of objects which are out of planes. In this study, we have devised an intuitive simple method to reduce the blur artifact based on an iterative approach. This method repeats a forward and backward projection procedure to determine the blur artifact affecting on the plane-of-interest (POI), and then subtracts it from the POI. The proposed method does not include any Fourierdomain operations hence excluding the Fourier-domain-originated artifacts. We describe the concept of the self-layer subtractive tomosynthesis and demonstrate its performance with numerical simulation and experiments. Comparative analysis with the conventional methods, such as the SAA and filtered backprojection methods, is addressed.

  3. Self-mixing differential vibrometer based on electronic channel subtraction

    International Nuclear Information System (INIS)

    Donati, Silvano; Norgia, Michele; Giuliani, Guido

    2006-01-01

    An instrument for noncontact measurement of differential vibrations is developed, based on the self-mixing interferometer. As no reference arm is available in the self-mixing configuration, the differential mode is obtained by electronic subtraction of signals from two (nominally equal) vibrometer channels, taking advantage that channels are servo stabilized and thus insensitive to speckle and other sources of amplitude fluctuation. We show that electronic subtraction is nearly as effective as field superposition. Common-mode suppression is 25-30 dB, the dynamic range (amplitude) is in excess of 100 μm, and the minimum measurable (differential) amplitude is 20 nm on aB=10 kHz bandwidth. The instrument has been used to measure vibrations of two metal samples kept in contact, revealing the hysteresis cycle in the microslip and gross-slip regimes, which are of interest in the study of friction induced vibration damping of gas turbine blades for aircraft applications

  4. Smooth bifurcation for variational inequalities based on Lagrange multipliers

    Czech Academy of Sciences Publication Activity Database

    Eisner, Jan; Kučera, Milan; Recke, L.

    2006-01-01

    Roč. 19, č. 9 (2006), s. 981-1000 ISSN 0893-4983 R&D Projects: GA AV ČR(CZ) IAA100190506 Institutional research plan: CEZ:AV0Z10190503 Keywords : abstract variational inequality * bifurcation * Lagrange multipliers Subject RIV: BA - General Mathematics

  5. Accuracy of digital subtraction radiography in combination with a contrast media in assessment of proximal caries depth

    Directory of Open Access Journals (Sweden)

    Farzad Esmaeili

    2008-07-01

    Full Text Available Background and aims. Radiography is used to diagnose the demineralization process and carious lesions; however, conventional radiography and direct digital images do not show these lesions when the amount of demineralization is less than 40%. Digital subtraction radiography has recently been used to improve the diagnostic quality of these lesions. The purpose of this study was to compare the caries depth estimated by digital subtraction radiography in combination with barium sulfate in diagnosing proximal dental caries with histopathologic evaluation. Materials and methods. In this study 30 molars and premolars (24 demineralized lesions with cavity, 8 without cavity were studied. Direct digital images were taken (kVp: 68, mA: 8; t: 0.12 for premolars and t: 0.16 for molars whereas the position of X-ray tube and CCD receptor and teeth was fixed. To prepare the second images 135 gr/L barium sulfate was used. The images obtained with the same exposure and geometry and then subtracted. The depth of the lesions in direct digital and subtracted images were assessed and compared with the depth measured in histopathologic assessments. Results. The mean depths (± SD of the lesions were 1.80 ± 0.77 mm in direct digital radiography, 2.32 ± 0.76 mm in subtracted images after barium sulfate treatment, and 2.51 ± 0.43 mm in histopathologic sections. The statistical difference between direct digital radiography and the other methods was significant (P < 0.05. However, the differences were not statistically significant between subtracted images and histopathologic sections. The average intra-class correlation coefficient was 0.7241 (CI: 95%. Conclusion. The present study has demonstrated that digital subtraction radiography images have the potential to measure the depth of proximal caries with no significant difference with histopathologic evaluation.

  6. An evaluation of the subtraction photoshop software accuracy to detect minor changes in optical density by radiovisiography

    Directory of Open Access Journals (Sweden)

    Talaeipour AR.

    2004-06-01

    Full Text Available Statement of Problem: Subtraction is a newly presented radiography technique to detect minor density"nchanges that are not visible by conventional radiography."nPurpose: The aim of this In-vitro study was to evaluate the efficacy of photoshop subtraction software for"ndetecting minor density changes between two dental images."nMaterials and Methods: In this research, five dried human mandibles were held in fixed position while thin"naluminium sheets were superimposed on each mandible on the 1th and 2nd molar teeth regions."nA reference image, without aluminium sheet placement, was obtained from each mandible subsequently series"nconsist of 20 images with aluminium sheets, ranging from 50p. to "5Q0"x were recorded by radiovisiography"n(RVG system. Initial images were subtracted from subsequent ones by Photoshop subtraction software. The"ndifference in density between the two images at the 1st and 2nd molar sites was related to the aluminium"nsheets. The optical density of aluminium sheets was determined by densitometer."nResults: In the present study, 6.6% of the optical density changes of the minimum aluminium thickness as"n300u. could be detected by photoshop software software."nConclusion: The findings of this study showed that the accuracy of photoshop subtraction software was equal"nto that of the conventional subtraction softwares. Additionally, the accuracy of this software was proved to be"nsuitable for clinical investigations of small localized changes in alveolar bone.

  7. Instructional Computing Project Uses "Multiplier Effect" to Train Florida Teachers.

    Science.gov (United States)

    Roblyer, M. D.; Castine, W. H.

    1987-01-01

    Reviews the efforts undertaken in the Florida Model Microcomputer Trainer Project (FMMTP) and its statewide impact. Outlines its procedural strategies, trainer curriculum, networking system, and the results of its multiplier effect. (ML)

  8. Rhinoplasty for the multiply revised nose.

    Science.gov (United States)

    Foda, Hossam M T

    2005-01-01

    To evaluate the problems encountered on revising a multiply operated nose and the methods used in correcting such problems. The study included 50 cases presenting for revision rhinoplasty after having had 2 or more previous rhinoplasties. An external rhinoplasty approach was used in all cases. Simultaneous septal surgery was done whenever indicated. All cases were followed for a mean period of 32 months (range, 1.5-8 years). Evaluation of the surgical result depended on clinical examination, comparison of pre- and postoperative photographs, and degree of patients' satisfaction with their aesthetic and functional outcome. Functionally, 68% suffered nasal obstruction that was mainly caused by septal deviations and nasal valve problems. Aesthetically, the most common deformities of the upper two thirds of the nose included pollybeak (64%), dorsal irregularities (54%), dorsal saddle (44%), and open roof deformity (42%), whereas the deformities of lower third included depressed tip (68%), tip contour irregularities (60%), and overrotated tip (42%). Nasal grafting was necessary in all cases; usually more than 1 type of graft was used in each case. Postoperatively, 79% of the patients, with preoperative nasal obstruction, reported improved breathing; 84% were satisfied with their aesthetic result; and only 8 cases (16%) requested further revision to correct minor deformities. Revision of a multiply operated nose is a complex and technically demanding task, yet, in a good percentage of cases, aesthetic as well as functional improvement are still possible.

  9. Fission multipliers for D-D/D-T neutron generators

    International Nuclear Information System (INIS)

    Lou, T.P.; Vujic, J.L.; Koivunoro, H.; Reijonen, J.; Leung, K.-N.

    2003-01-01

    A compact D-D/D-T fusion based neutron generator is being designed at the Lawrence Berkeley National Laboratory to have a potential yield of 10 12 D-D n/s and 10 14 D-T n/s. Because of its high neutron yield and compact size (∼20 cm in diameter by 4 cm long), this neutron generator design will be suitable for many applications. However, some applications required higher flux available from nuclear reactors and spallation neutron sources operated with GeV proton beams. In this study, a subcritical fission multiplier with k eff of 0.98 is coupled with the compact neutron generators in order to increase the neutron flux output. We have chosen two applications to show the gain in flux due to the use of fission multipliers--in-core irradiation and out-of-core irradiation. For the in-core irradiation, we have shown that a gain of ∼25 can be achieved in a positron production system using D-T generator. For the out-of-core irradiation, a gain of ∼17 times is obtained in Boron Neutron Capture Therapy (BNCT) using a D-D neutron generator. The total number of fission neutrons generated by a source neutron in a fission multiplier with k eff is ∼50. For the out-of-core irradiation, the theoretical maximum net multiplication is ∼30 due to the absorption of neutrons in the fuel. A discussion of the achievable multiplication and the theoretical multiplication will be presented in this paper

  10. Digital subtraction angiography in the diagnosis of Fallot's tetralogy

    International Nuclear Information System (INIS)

    Ivanitskij, A.V.; Tereshkin, Ya.A.; Sobolev, A.V.; Stolyar, V.L.; Slyunyastikov, M.A.

    1995-01-01

    The authors analyze the efficacy of digital subtraction angiography (DSA) in the diagnosis of Fallot's tetralogy (FT); this method helps simplity and cut down their scope of investigations but does not deteriorate their informative value. DSA findings in 120 patients with TF are analyzed. 5 refs.; 6 figs

  11. Different I/O Standard and Technology Based Thermal Aware Energy Efficient Vedic Multiplier Design for Green Wireless Communication on FPGA

    DEFF Research Database (Denmark)

    Goswami, Kavita; Pandey, Bishwajeet; Kumar, Tanesh

    2017-01-01

    and that eventually decrease power dissipation of wireless communications systems. In order to study the effect of different process technology (40, 65, 90 nm) on our design, a novel design is implemented on 40, 65 and 90 nm based FPGA. In this work, we are integrating thermal aware design approach for energy......This paper deals with low power multiplier design that plays a significant role in green wireless communications systems. Over the period of time, researchers have proposed various multiplier designs in order to get high speed. Vedic multiplier is considered as one of the low power multiplier along...... with high speed as compared with traditional array and booth multipliers. Vedic Multiplier contains a total of sixteen algorithms/sutras for predominantly logical operations. This research focuses on thermal aspects and energy efficiency of wireless communications systems with the thermal aware low power...

  12. Utilization of a channel electron multiplier for counting-measurement on condensed molecular jet

    International Nuclear Information System (INIS)

    Le Bihan, A.M.; Bottiglioni, F.; Coutant, J.; Fois, M.; CEA Centre d'Etudes Nucleaires de Fontenay-aux-Roses, 92

    1974-01-01

    A channel electron multiplier has been used for counting ionized clusters containing up to a few thousands molecules; clusters are accelerated towards a negative (approximately-220V) copper target; a larger negative bias (approximately-3000V) is applied to the multiplier entrance so as to collect positive secondary ions and/or reflected cluster fragments; in the present application this gives better signal to noise ratio than detecting clusters directly or by secondary electron emission on the target [fr

  13. Radiation-hardened I2L 8*8 multiplier circuit

    International Nuclear Information System (INIS)

    Doyle, B.R.; Kreps, S.A.; Van Vonno, N.W.; Lake, G.W.

    1979-01-01

    Development of improved Substrate Fed I 2 L (SFL) processing has been combined with geometry and fanout constraints to design a radiation hardened LSI 8.8 Multiplier. This study describes details of the process and circuit design and gives resultant electrical and radiation test performance

  14. Tumor scintigraphy by the method for subtracting the initial image with technetium-99m labeled antibody

    International Nuclear Information System (INIS)

    Karube, Yoshiharu; Katsuno, Kentaro; Ito, Sanae; Matsunaga, Kazuhisa; Takata, Jiro; Kuroki, Masahide; Murakami, Masaaki; Matsuoka, Yuji

    1999-01-01

    The method for subtracting the initial image from the localization image was evaluated for radioimmunoscintigraphy of tumors with technetium-99m (Tc-99m) labeled antibodies. Monoclonal antibodies were parental mouse and mouse-human chimeric antibodies to carcinoembryonic antigen (CEA), designated F11-39 and ChF11-39, respectively, both of which have been found to discriminate CEA in tumor tissues from the CEA-related antigens. After reduction of the intrinsic disulfide bonds, these antibodies were labeled with Tc-99m. In vivo studies were performed on athymic nude mice bearing the human CEA-producing gastric carcinoma xenografts. Though biodistribution results showed selective and progressive accumulation of Tc-99m labeled antibodies at the tumor site, high radioactivity in blood was inappropriate for scintigraphic visualization of the tumors within a few hours. We examined the subtraction of the initial Tc-99m image from the Tc-99m localization image after a few hours. Subtracted images of the same count reflected the in vivo behavior of the Tc-99m radioactivity. The subtracted scintigrams revealed excellent tumor images with no significant extrarenal background. Visualization of the tumor site was dependent on antigen-specific binding and nonspecific exudation. These results demonstrate that a method of subtraction of the initial image may serve as a potentially useful diagnostic method for an abnormal site for agents with a low pharmacokinetic value. (author)

  15. Lower-Order Compensation Chain Threshold-Reduction Technique for Multi-Stage Voltage Multipliers

    Directory of Open Access Journals (Sweden)

    Francesco Dell’ Anna

    2018-04-01

    Full Text Available This paper presents a novel threshold-compensation technique for multi-stage voltage multipliers employed in low power applications such as passive and autonomous wireless sensing nodes (WSNs powered by energy harvesters. The proposed threshold-reduction technique enables a topological design methodology which, through an optimum control of the trade-off among transistor conductivity and leakage losses, is aimed at maximizing the voltage conversion efficiency (VCE for a given ac input signal and physical chip area occupation. The conducted simulations positively assert the validity of the proposed design methodology, emphasizing the exploitable design space yielded by the transistor connection scheme in the voltage multiplier chain. An experimental validation and comparison of threshold-compensation techniques was performed, adopting 2N5247 N-channel junction field effect transistors (JFETs for the realization of the voltage multiplier prototypes. The attained measurements clearly support the effectiveness of the proposed threshold-reduction approach, which can significantly reduce the chip area occupation for a given target output performance and ac input signal.

  16. Mining, regional Australia and the economic multiplier

    Directory of Open Access Journals (Sweden)

    Paul Cleary

    2012-12-01

    Full Text Available Mining in Australia has traditionally delivered a strong development multiplier for regional communities where most mines are based. This relationship has weakened in recent decades as a result of the introduction of mobile workforces - typically known as fly in, fly out. Political parties have responded with policies known as ‘royalties for regions’, though in designing them they overlooked long established Indigenous arrangements for sharing benefits with areas affected directly by mining.

  17. Counting the mismatches - lung ventilation/perfusion subtraction index

    International Nuclear Information System (INIS)

    Anderson, T.C.; Evans, S.G.; Larcos, G.; Farlow, D.C.

    1998-01-01

    Full text: There is potential for interobserver variability in interpretation of ventilation/perfusion (V/Q) scans. Objective quantification of V/Q mismatch could be useful. Thus, the aim of this study is to determine the validity of image subtraction in a group of 27 patients (11 men, 8 women; mean age 59.4 years [range 21-81 years])investigated by V/Q scans for suspected pulmonary emboli. A standard 6 view V/Q scan was obtained with two cobalt markers used on the anterior and posterior surfaces for image alignment. Ventilation images were normalised to the perfusion using an area of normal ventilation and perfusion. With the use of automated, and if required, manual alignment, perfusion images were subtracted from ventilation, with a median filter applied. A summed index of mismatch for each lung scan was calculated from the difference. This index was then retrospectively compared to the result reported by one of four experienced physicians. Two patients with chronic obstructive airways disease were excluded from analysis. We conclude that high probability V/Q scans can be differentiated from low probability studies using this index; further prospective investigation in a larger cohort is warranted

  18. Determination of the kalium-subtracted total beta in food

    International Nuclear Information System (INIS)

    Liu Guofan

    1985-01-01

    A procedure for measuring the kalium-subtracted total beta in food can be applied to estimating the contamination of beta nuclides except 40 K. The procedure, calculating formula, and some experiences in practice are described in this paper. The method is simple, rapid, and very useful to food contamination monitoring

  19. Continuous-variable measurement-device-independent quantum key distribution with virtual photon subtraction

    Science.gov (United States)

    Zhao, Yijia; Zhang, Yichen; Xu, Bingjie; Yu, Song; Guo, Hong

    2018-04-01

    The method of improving the performance of continuous-variable quantum key distribution protocols by postselection has been recently proposed and verified. In continuous-variable measurement-device-independent quantum key distribution (CV-MDI QKD) protocols, the measurement results are obtained from untrusted third party Charlie. There is still not an effective method of improving CV-MDI QKD by the postselection with untrusted measurement. We propose a method to improve the performance of coherent-state CV-MDI QKD protocol by virtual photon subtraction via non-Gaussian postselection. The non-Gaussian postselection of transmitted data is equivalent to an ideal photon subtraction on the two-mode squeezed vacuum state, which is favorable to enhance the performance of CV-MDI QKD. In CV-MDI QKD protocol with non-Gaussian postselection, two users select their own data independently. We demonstrate that the optimal performance of the renovated CV-MDI QKD protocol is obtained with the transmitted data only selected by Alice. By setting appropriate parameters of the virtual photon subtraction, the secret key rate and tolerable excess noise are both improved at long transmission distance. The method provides an effective optimization scheme for the application of CV-MDI QKD protocols.

  20. Photoionization of multiply charged ions at the advanced light source

    International Nuclear Information System (INIS)

    Schlachter, A.S.; Kilcoyne, A.L.D.; Aguilar, A.; Gharaibeh, M.F.; Emmons, E.D.; Scully, S.W.J.; Phaneuf, R.A.; Muller, A.; Schippers, S.; Alvarez, I.; Cisneros, C.; Hinojosa, G.; McLaughlin, B.M.

    2004-01-01

    Photoionization of multiply charged ions is studied using the merged-beams technique at the Advanced Light Source. Absolute photoionization cross sections have been measured for a variety of ions along both isoelectronic and isonuclear sequences

  1. Exponential decay and exponential recovery of modal gains in high count rate channel electron multipliers

    International Nuclear Information System (INIS)

    Hahn, S.F.; Burch, J.L.

    1980-01-01

    A series of data on high count rate channel electron multipliers revealed an initial drop and subsequent recovery of gains in exponential fashion. The FWHM of the pulse height distribution at the initial stage of testing can be used as a good criterion for the selection of operating bias voltage of the channel electron multiplier

  2. ANALYSIS OF THE INVESTMENT ARBITRAGE STRATEGY USING FINANCIAL MULTIPLIERS

    Directory of Open Access Journals (Sweden)

    Dmitry S. Pashkov

    2013-01-01

    Full Text Available This article describes an algorithm for stock pairs trading using financial multipliers of underlying companies. This algorithm has been tested on historical data and compared with classical Bollinger bands strategy. The results of tests were presented for two financial sectors of US stock market.

  3. Venous digital subtraction angiography of the renal arteries in hypertensive patients

    International Nuclear Information System (INIS)

    Brecht, G.; Harder, T.; Franken, T.

    1984-01-01

    We carried out 1890 venous digital subtraction angiograms; this included 113 patients with hypertension in order to exclude renal artery stenosis. On four occasions it was used following surgery on a renal artery. Renal artery stenosis or occlusion was demonstrated in twelve patients, and other vascular diseases or anomalies were found in 24. Two abnormal renal arteries were found following renal artery surgery. The results are compared with smaller groups of patients examined by DSA, and with the results of conventional subtraction methods reported in the literature. In only eight patients (6.8%) DSA provided insufficient information and had to be supplemented by aortography. The method has proved to be a valuable and simple screening method for the investigation of hypertension. (orig.) [de

  4. [X-ray semiotics of sialolithiasis in functional digital subtraction sialography].

    Science.gov (United States)

    Iudin, L A; Kondrashin, S A; Afanas'ev, V V; Shchipskiĭ, A V

    1995-01-01

    Twenty-seven patients with sialolithiasis were examined using functional subtraction sialography developed by the authors. Differential diagnostic signs characterizing the degree of involvement of the salivary gland were defined. High efficacy of the method helps correctly plan the treatment strategy.

  5. Generation of fast multiply charged ions in conical targets

    International Nuclear Information System (INIS)

    Demchenko, V.V.; Chukbar, K.V.

    1990-01-01

    So-called conical targets, when the thermonuclear fuel is compressed and heated in a conical cavity in a heavy material (lead, gold, etc.) with the help of a spherical segment that is accelerated by a laser pulse or a beam of charged particles, are often employed in experimental studies of inertial-confinement fusion. In spite of the obvious advantages of such a scheme, one of which is a significant reduction of the required energy input compared with the complete spherical target, it also introduces additional effects into the process of cumulation of energy. In this paper the authors call attention to an effect observed in numerical calculations: the hydrodynamic heating of a small group of multiply charged heavy ions of the walls of the conical cavity up to high energies (T i approx-gt 100 keV). This effect ultimately occurs as a result of the high radiation losses of a multiply charged plasma

  6. PCA-based approach for subtracting thermal background emission in high-contrast imaging data

    Science.gov (United States)

    Hunziker, S.; Quanz, S. P.; Amara, A.; Meyer, M. R.

    2018-03-01

    Aims.Ground-based observations at thermal infrared wavelengths suffer from large background radiation due to the sky, telescope and warm surfaces in the instrument. This significantly limits the sensitivity of ground-based observations at wavelengths longer than 3 μm. The main purpose of this work is to analyse this background emission in infrared high-contrast imaging data as illustrative of the problem, show how it can be modelled and subtracted and demonstrate that it can improve the detection of faint sources, such as exoplanets. Methods: We used principal component analysis (PCA) to model and subtract the thermal background emission in three archival high-contrast angular differential imaging datasets in the M' and L' filter. We used an M' dataset of β Pic to describe in detail how the algorithm works and explain how it can be applied. The results of the background subtraction are compared to the results from a conventional mean background subtraction scheme applied to the same dataset. Finally, both methods for background subtraction are compared by performing complete data reductions. We analysed the results from the M' dataset of HD 100546 only qualitatively. For the M' band dataset of β Pic and the L' band dataset of HD 169142, which was obtained with an angular groove phase mask vortex vector coronagraph, we also calculated and analysed the achieved signal-to-noise ratio (S/N). Results: We show that applying PCA is an effective way to remove spatially and temporarily varying thermal background emission down to close to the background limit. The procedure also proves to be very successful at reconstructing the background that is hidden behind the point spread function. In the complete data reductions, we find at least qualitative improvements for HD 100546 and HD 169142, however, we fail to find a significant increase in S/N of β Pic b. We discuss these findings and argue that in particular datasets with strongly varying observing conditions or

  7. Analytical optimization of digital subtraction mammography with contrast medium using a commercial unit.

    Science.gov (United States)

    Rosado-Méndez, I; Palma, B A; Brandan, M E

    2008-12-01

    Contrast-medium-enhanced digital mammography (CEDM) is an image subtraction technique which might help unmasking lesions embedded in very dense breasts. Previous works have stated the feasibility of CEDM and the imperative need of radiological optimization. This work presents an extension of a former analytical formalism to predict contrast-to-noise ratio (CNR) in subtracted mammograms. The goal is to optimize radiological parameters available in a clinical mammographic unit (x-ray tube anode/filter combination, voltage, and loading) by maximizing CNR and minimizing total mean glandular dose (D(gT)), simulating the experimental application of an iodine-based contrast medium and the image subtraction under dual-energy nontemporal, and single- or dual-energy temporal modalities. Total breast-entrance air kerma is limited to a fixed 8.76 mGy (1 R, similar to screening studies). Mathematical expressions obtained from the formalism are evaluated using computed mammographic x-ray spectra attenuated by an adipose/glandular breast containing an elongated structure filled with an iodinated solution in various concentrations. A systematic study of contrast, its associated variance, and CNR for different spectral combinations is performed, concluding in the proposal of optimum x-ray spectra. The linearity between contrast in subtracted images and iodine mass thickness is proven, including the determination of iodine visualization limits based on Rose's detection criterion. Finally, total breast-entrance air kerma is distributed between both images in various proportions in order to maximize the figure of merit CNR2/D(gT). Predicted results indicate the advantage of temporal subtraction (either single- or dual-energy modalities) with optimum parameters corresponding to high-voltage, strongly hardened Rh/Rh spectra. For temporal techniques, CNR was found to depend mostly on the energy of the iodinated image, and thus reduction in D(gT) could be achieved if the spectral energy

  8. Beyond the static money multiplier: in search of a dynamic theory of money

    OpenAIRE

    Berardi, Michele

    2007-01-01

    In this paper, we analyze the process of money creation in a credit economy. We start from the consideration that the traditional money multiplier is a poor description of this process and present an alternative and dynamic approach that takes into account the heterogeneity of agents in the economy and their interactions. We show that this heterogeneity can account for the instability of the multiplier and that it can make the system path-dependent. By using concepts and techniques borrowed f...

  9. Intraarterial digital subtraction angiography in neuroradiology

    International Nuclear Information System (INIS)

    Zeumer, H.

    1987-01-01

    Neuroradiology always could make best use of subtraction methods, due to the relative immobility and constant shape of the skull. Arterial DSA now has extended the potential uses while reducing the patient's radiation exposure, the contrast medium dosage and osmolarity. The considerable cut-back in time required for invasive examination has reduced the risk of diagnostic and therapeutic measures. The advantages consisting of immediate image display with high contrast resolution in most of the diagnostic tasks counterbalance the disadvantage of low focal resolution of the DSA in neuroradiology. Interventional neuroradiology today cannot do without i.a. DSA. (orig.) [de

  10. Navy Additive Manufacturing: Adding Parts, Subtracting Steps

    Science.gov (United States)

    2015-06-01

    consumers shifted buying preferences to vehicles that had higher gas mileage. Figure 13 depicts declining sales for GM, Ford, and Chrysler from 2004... Toyota leads the most costly recall in history when they recalled close to 9 million vehicles for models between 2004–2010 (Avalon, Camry, Corolla, Matrix...cases of runaway vehicles, half resulted in at least one death; thus, “ Toyota issued two separate recalls in 2009 and 2010 to ‘reconfigure’ the

  11. Aggression-related brain function assessed with the Point Subtraction Aggression Paradigm in fMRI

    DEFF Research Database (Denmark)

    Skibsted, Anine P; Cunha-Bang, Sofi da; Carré, Justin M

    2017-01-01

    The Point Subtraction Aggression Paradigm (PSAP) measures aggressive behavior in response to provocations. The aim of the study was to implement the PSAP in a functional neuroimaging environment (fMRI) and evaluate aggression-related brain reactivity including response to provocations and associa......The Point Subtraction Aggression Paradigm (PSAP) measures aggressive behavior in response to provocations. The aim of the study was to implement the PSAP in a functional neuroimaging environment (fMRI) and evaluate aggression-related brain reactivity including response to provocations...... and associations with aggression within the paradigm. Twenty healthy participants completed two 12-min PSAP sessions within the scanner. We evaluated brain responses to aggressive behavior (removing points from an opponent), provocations (point subtractions by the opponent), and winning points. Our results showed...... with the involvement of these brain regions in emotional and impulsive behavior. Striatal reactivity may suggest an involvement of reward during winning and stealing points....

  12. Effect of relative nanohole position on colour purity of ultrathin plasmonic subtractive colour filters

    International Nuclear Information System (INIS)

    Sun, L B; Hu, X L; Zhang, D X; Zeng, Beibei; Wang, L S; Yang, S M; Tai, R Z; Fecht, H J; Jiang, J Z

    2015-01-01

    Plasmonic subtractive color filters through patterning periodic nanostructures on ultrathin Ag films deposited on a glass substrate, exhibiting good durability, simple fabrication, and flexible color tunability, have attracted considerable attention due to their tremendous potential applications. While previous studies have mainly focused on their extraordinary physical mechanisms, color purity, which is another key parameter for high quality imaging applications, has been much less investigated. In this work, we demonstrate that the relative position of nanoholes patterned on ultrathin Ag films can largely affect the color purity of plasmonic subtractive color filters. The calculated results agree reasonably well with the experimental data, revealing that the purity of subtractive colors can be improved by changing the nanohole arrays from square lattice to triangular lattice without reducing transmission at visible frequencies. In addition, underlying mechanisms are clarified by systematically analyzing the dominant valley in transmission spectra. (paper)

  13. A study on computer-aided diagnosis based on temporal subtraction of sequential chest radiographs (in Japanese)

    International Nuclear Information System (INIS)

    Kano, Akiko

    2001-01-01

    An automated digital image subtraction technique for use with pairs of temporally sequential chest radiographs has been developed to aid radiologists in the detection of interval changes. Automated image registration based on nonlinear geometric warping is performed prior to subtraction in order to deal with complicated radiographic misregistration. Processing includes global matching, to achieve rough registration between the entire lung fields in the two images, and local matching, based on a cross-correlation method, to determine local shift values for a number of small regions. A proper warping of x,y-coordinates is determined by fitting two-dimensional polynomials to the distributions of the shift values. One image is warped and then subtracted from the other. The resultant subtraction images were able to enhance the conspicuity of various types of interval changes. Improved global matching based on a weighted template matching method achieved robust registration even with photofluorographs taken in chest mass screening programs, which had previously presented us with a relatively large number of poor-registration images. The new method was applied to 129 pairs of chest mass screening images, and offered registration accuracy as good as manual global matching. An observer test using 114 cases including 57 lung cancer cases presented better sensitivity and specificity on average compared to conventional comparison readings. In addition, newly developed image processing that eliminates the rib edge artifacts in subtraction images was applied to 26 images having pathological interval changes; results showed the potential for application to automated schemes for the detection of interval change patterns. With its capacity to improve the diagnostic accuracy of chest radiographs, the chest temporal subtraction technique promises to become an important element of computer-aided diagnosis (CAD) systems

  14. Construction and identification of subtracted cDNA library in bone marrow cells of radon-exposed mice

    International Nuclear Information System (INIS)

    Li Jianxiang; Nie Jihua; Tong Jian; Fu Chunling; Zhou Jianwei

    2008-01-01

    Objective: To construct and identify subtracted cDNA library in bone marrow cells of mice exposed to radon inhalation. Methods: Adult male BALB/c mice, weighing 18-22 g, were placed in a multi- functional radon chamber. One group of mice was exposed to radon up to the accumulative dose of 105 work level month (WLM). The control group of mice was housed in a room with an accumulative dose of 1 WLM. To construct a subtracted cDNA library enriched with differentially expressed genes, the SMART technique and the suppression subtractive hybridization were performed. The obtained forward and reverse cDNA fragments were directly inserted into pMD18-T vector and transformed into E. coli JM109. The inserting cDNA fragments were screened by the blue-and-white blot screening and nested PCR of bacterium liquid. Results: The 244 of 285 white bacteria clones obtained randomly were positive clones contained 100-1100 bp inserted cDNA fragments. Conclusions: The forward and reverse subtracted cDNA library in bone marrow cells of mice exposed to radon inhalation is successfully constructed. (authors)

  15. Enhancing quantum entanglement for continuous variables by a coherent superposition of photon subtraction and addition

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Su-Yong; Kim, Ho-Joon [Department of Physics, Texas A and M University at Qatar, P.O. Box 23874, Doha (Qatar); Ji, Se-Wan [School of Computational Sciences, Korea Institute for Advanced Study, Seoul 130-012 (Korea, Republic of); Nha, Hyunchul [Department of Physics, Texas A and M University at Qatar, P.O. Box 23874, Doha (Qatar); Institute fuer Quantenphysik, Universitaet Ulm, D-89069 Ulm (Germany)

    2011-07-15

    We investigate how the entanglement properties of a two-mode state can be improved by performing a coherent superposition operation ta+ra{sup {dagger}} of photon subtraction and addition, proposed by Lee and Nha [Phys. Rev. A 82, 053812 (2010)], on each mode. We show that the degree of entanglement, the Einstein-Podolsky-Rosen-type correlation, and the performance of quantum teleportation can be all enhanced for the output state when the coherent operation is applied to a two-mode squeezed state. The effects of the coherent operation are more prominent than those of the mere photon subtraction a and the addition a{sup {dagger}} particularly in the small-squeezing regime, whereas the optimal operation becomes the photon subtraction (case of r=0) in the large-squeezing regime.

  16. Evaporator line for special electron tubes, in particular electron multipliers

    International Nuclear Information System (INIS)

    Richter, M.

    1984-01-01

    The invention has been aimed at reducing the effort for preventing short circuits in achieving certain material-dependent effects e.g. secondary emission, by deposition through evaporation in the production of electron tubes, in particular electron multipliers

  17. A database analysis of information on multiply charged ions

    International Nuclear Information System (INIS)

    Delcroix, J.L.

    1989-01-01

    A statistical analysis of data related to multiply charged ions, is performed in GAPHYOR data base: over-all statistics by ionization degree from q=1 to q=99, 'historical' development from 1975 to 1987, distribution (for q≥ 5) over physical processes (energy levels, charge exchange,...) and chemical elements

  18. Familiar Sports and Activities Adapted for Multiply Impaired Persons.

    Science.gov (United States)

    Schilling, Mary Lou, Ed.

    1984-01-01

    Means of adapting some familiar and popular physical activities for multiply impaired persons are described. Games reviewed are dice baseball, one base baseball, in-house bowling, wheelchair bowling, ramp bowling, swing-ball bowling, table tennis, shuffleboard, beanbag bingo and tic-tac-toe, balloon basketball, circle football, and wheelchair…

  19. Multiply-negatively charged aluminium clusters and fullerenes

    Energy Technology Data Exchange (ETDEWEB)

    Walsh, Noelle

    2008-07-15

    Multiply negatively charged aluminium clusters and fullerenes were generated in a Penning trap using the 'electron-bath' technique. Aluminium monoanions were generated using a laser vaporisation source. After this, two-, three- and four-times negatively charged aluminium clusters were generated for the first time. This research marks the first observation of tetra-anionic metal clusters in the gas phase. Additionally, doubly-negatively charged fullerenes were generated. The smallest fullerene dianion observed contained 70 atoms. (orig.)

  20. Tax Multipliers: Pitfalls in Measurement and Identification

    OpenAIRE

    Daniel Riera-Crichton; Carlos A. Vegh; Guillermo Vuletin

    2012-01-01

    We contribute to the literature on tax multipliers by analyzing the pitfalls in identification and measurement of tax shocks. Our main focus is on disentangling the discussion regarding the identification of exogenous tax policy shocks (i.e., changes in tax policy that are not the result of policymakers responding to output fluctuations) from the discussion related to the measurement of tax policy (i.e., finding a tax policy variable under the direct control of the policymaker). For this purp...

  1. An analysis of the influence of background subtraction and quenching on jet observables in heavy-ion collisions

    CERN Document Server

    Apolinario, Liliana; Cunqueiro, Leticia

    2013-01-01

    Subtraction of the large background in reconstruction is a key ingredient in jet studies in high-energy heavy-ion collisions at RHIC and the LHC. Here we address the question to which extent the most commonly used subtraction techniques are able to eliminate the effects of the background on the most commonly discussed observables at present: single inclusive jet distributions, dijet asymmetry and azimuthal distributions. We consider two different background subtraction methods, an area-based one implemented through the FastJet pack- age and a pedestal subtraction method, that resemble the ones used by the experimental collaborations at the LHC. We also analyze different ways of defining the optimal parame- ters in the second method. We use a toy model that easily allows variations of the background characteristics: average background level and fluctuations and azimuthal structure, but cross- checks are also done with a Monte Carlo simulator. Furthermore, we consider the influence of quenching using Q-PYTHIA o...

  2. New Lagrange Multipliers for the Blind Adaptive Deconvolution Problem Applicable for the Noisy Case

    Directory of Open Access Journals (Sweden)

    Monika Pinchas

    2016-02-01

    Full Text Available Recently, a new blind adaptive deconvolution algorithm was proposed based on a new closed-form approximated expression for the conditional expectation (the expectation of the source input given the equalized or deconvolutional output where the output and input probability density function (pdf of the deconvolutional process were approximated with the maximum entropy density approximation technique. The Lagrange multipliers for the output pdf were set to those used for the input pdf. Although this new blind adaptive deconvolution method has been shown to have improved equalization performance compared to the maximum entropy blind adaptive deconvolution algorithm recently proposed by the same author, it is not applicable for the very noisy case. In this paper, we derive new Lagrange multipliers for the output and input pdfs, where the Lagrange multipliers related to the output pdf are a function of the channel noise power. Simulation results indicate that the newly obtained blind adaptive deconvolution algorithm using these new Lagrange multipliers is robust to signal-to-noise ratios (SNR, unlike the previously proposed method, and is applicable for the whole range of SNR down to 7 dB. In addition, we also obtain new closed-form approximated expressions for the conditional expectation and mean square error (MSE.

  3. Features of produced flows of multiply charged ions at interaction of laser radiation with single-component solids

    International Nuclear Information System (INIS)

    Bedilov, M.R.; Bedilov, R.M.; Beysembaeva, H.B.; Sabitov, M.S.; Kamalova, J.O.

    2006-01-01

    Full text: The results of study features of formation multiply charged ions spectra of single-component solids depending on a target element composition in an interval of laser radiation power density q = 10 7 / 10 12 W/cm 2 with using of the laser multiply charged mass spectrometer [1] are given in this work. As single-component targets are used Be, B, C, Al, Ti, Fe, Co, Ni, Cu, Ag, Ta, W, Pt, Au as tablets in diameter of 10 mm and thickness of 3-5 mm. Analysis of the obtained mass-charge and energy spectra of multiply charged ions depending on a target element composition has allowed us to find features of formation spectra and escape multiply charged ions of a single-component targets. These features consist in characteristic changes: a threshold produced of ions; formation of mass-charge and energy spectra of multiply charged ions; nonlinear dependence of maximal charge number (Z max ) of ions from power density (q) of the laser; etc. Experimentally it was found that, with target atomic weight increase, threshold power of ions occurrence, nonlinearity ionization target structure, and intensity of ions, and energy spectra of ions increase. Let's note that, in case of targets Be, B, C, Al by laser radiation it is completely ionized and multiply charged ions and nuclei Be 4+ , B 5+ , C 6+ , Al 13+ are formed. The major level of ionization is attained in case of targets from Ti (Ti 17+ ) and Co (Co 18+ ). It is peculiar that structure formation and escape of multiply charged ion flows with Z max and nuclei depending on target element composition corresponds to various maximal values q of the laser. Increase of the maximal charge number of ions (atoms) observed with increase q of the laser for all investigated targets has nonlinear dependence in various levels that is especially shown beginning from q≥ 10 11 W/cm 2 . It is found that depending on target element composition multiply charged ions have a wide energy range with a maximum of allocation. With increase

  4. Spectral multipliers on spaces of distributions associated with non-negative self-adjoint operators

    DEFF Research Database (Denmark)

    Georgiadis, Athanasios; Nielsen, Morten

    2018-01-01

    and Triebel–Lizorkin spaces with full range of indices is established too. As an application, we obtain equivalent norm characterizations for the spaces mentioned above. Non-classical spaces as well as Lebesgue, Hardy, (generalized) Sobolev and Lipschitz spaces are also covered by our approach.......We consider spaces of homogeneous type associated with a non-negative self-adjoint operator whose heat kernel satisfies certain upper Gaussian bounds. Spectral multipliers are introduced and studied on distributions associated with this operator. The boundedness of spectral multipliers on Besov...

  5. Identification of multiply charged proteins and amino acid clusters by liquid nitrogen assisted spray ionization mass spectrometry.

    Science.gov (United States)

    Kumar Kailasa, Suresh; Hasan, Nazim; Wu, Hui-Fen

    2012-08-15

    The development of liquid nitrogen assisted spray ionization mass spectrometry (LNASI MS) for the analysis of multiply charged proteins (insulin, ubiquitin, cytochrome c, α-lactalbumin, myoglobin and BSA), peptides (glutathione, HW6, angiotensin-II and valinomycin) and amino acid (arginine) clusters is described. The charged droplets are formed by liquid nitrogen assisted sample spray through a stainless steel nebulizer and transported into mass analyzer for the identification of multiply charged protein ions. The effects of acids and modifier volumes for the efficient ionization of the above analytes in LNASI MS were carefully investigated. Multiply charged proteins and amino acid clusters were effectively identified by LNASI MS. The present approach can effectively detect the multiply charged states of cytochrome c at 400 nM. A comparison between LNASI and ESI, CSI, SSI and V-EASI methods on instrumental conditions, applied temperature and observed charge states for the multiply charged proteins, shows that the LNASI method produces the good quality spectra of amino acid clusters at ambient conditions without applied any electric field and heat. To date, we believe that the LNASI method is the most simple, low cost and provided an alternative paradigm for production of multiply charged ions by LNASI MS, just as ESI-like ions yet no need for applying any electrical field and it could be operated at low temperature for generation of highly charged protein/peptide ions. Copyright © 2012 Elsevier B.V. All rights reserved.

  6. Sky subtraction at the Poisson limit with fibre-optic multiobject spectroscopy

    Science.gov (United States)

    Sharp, R.; Parkinson, H.

    2010-11-01

    We report on the limitations of sky-subtraction accuracy for long-duration fibre-optic multiobject spectroscopy of faint astronomical sources during long-duration exposures. We show that while standard sky subtraction techniques yield accuracies consistent with the Poisson noise limit for exposures of 1h duration, there are large-scale systematic defects that inhibit the sensitivity gains expected on the summation of longer duration exposures. For the AAOmega system at the Anglo-Australian Telescope, we identify a limiting systematic sky-subtraction accuracy, which is reached after integration times of 4-10h. We show that these systematic defects can be avoided through the use of the fibre nod-and-shuffle (N+S) observing mode, but with a potential cost in observing efficiency. Finally, we demonstrate that these disadvantages can be overcome through the application of a Principal Components Analysis (PCA) sky-subtraction routine. Such an approach minimize systematic residuals across long-duration exposures, allowing deep integrations. We apply the PCA approach to over 200h of on-sky observations and conclude that for the AAOmega system, the residual error in long-duration observations falls at a rate proportional to τ-0.32 in contrast to the τ-0.5 rate expected from theoretical considerations. With this modest rate of decline, the PCA approach represents a more efficient mode of observation than the N+S technique for observations in the sky limited regime with durations of 10-100h (even before accounting for the additional signal-to-noise ratio and targeting efficiency losses often associated with the N+S technique). This conclusion has important implications for the observing strategies of the next generation of fibre-optics redshift surveys with existing facilities as well as design implications for fibre-optic systems destined for new facilities. It argues against the use of the inherently inefficient N+S technique for faint object fibre-optic survey

  7. Supersymmetric AdS3, AdS2 and bubble solutions

    International Nuclear Information System (INIS)

    Gauntlett, Jerome P.; Waldram, Daniel; Kim, Nakwoo

    2007-01-01

    We present new supersymmetric AdS 3 solutions of type IIB supergravity and AdS 2 solutions of D = 11 supergravity. The former are dual to conformal field theories in two dimensions with N = (0, 2) supersymmetry while the latter are dual to conformal quantum mechanics with two supercharges. Our construction also includes AdS 2 solutions of D = 11 supergravity that have non-compact internal spaces which are dual to three-dimensional N = 2 superconformal field theories coupled to point-like defects. We also present some new bubble-type solutions, corresponding to BPS states in conformal theories, that preserve four supersymmetries

  8. Clinical evaluation of dual-energy bone removal in CT angiography of the head and neck: comparison with conventional bone-subtraction CT angiography

    International Nuclear Information System (INIS)

    Deng, K.; Liu, C.; Ma, R.; Sun, C.; Wang, X.-M.; Ma, Z.-T.; Sun, X.-L.

    2009-01-01

    Aim: To evaluate the bone-subtraction effect of dual-energy bone removal in computed tomography angiography (CTA) of the head and neck in comparison with conventional bone-subtraction CTA. Material and Methods: The study comprised 52 patients who were divided into two groups at random, and examined using dual-source CT for head and neck CTA. Dual-energy bone removal CTA and conventional bone-subtraction CTA were applied to each of the two groups, respectively. The bone subtraction was performed automatically in both methods. Vascular structures, as well as brain tissue remained visible. The subtracted images were further processed with maximum intensity projection (MIP) and volume-rendering technique (VRT) for image evaluation. Two experienced radiologists reviewed the resulting subtracted and non-subtracted volume data with respect to the delineation and detection of image quality and vascular pathology. Results: The means of the weighted CT dose index (CTDIvol) for bone-removal dual-energy CTA and conventional bone-subtraction CTA were 20.56 ± 0.01 mGy and 25.57 ± 0.56 mGy, respectively. There was a significant difference between them. The percentage of carotid and vertebral arteries and all other vessels that could be successfully assessed with these two methods were 87.8, 68, and 83%, and 93.5, 91.8, and 92.6%, respectively. There were no significant differences in the visualization of the carotid arteries; however, there were significant differences in the visualization of the vertebral arteries. Conclusion: Compared with conventional bone-subtraction CTA, dual-energy bone-removal CTA had a lower radiation dose. It eliminated most bones in the head and neck successfully; however, the bone subtraction effect around the vertebral artery was unsatisfactory. Dual-energy bone-removal CTA provides a new method for detecting vascular diseases in routine clinical work.

  9. The added value of contrast enhanced spectral mammography in identification of multiplicity of suspicious lesions in dense breast

    Directory of Open Access Journals (Sweden)

    Amr Farouk Ibrahim Moustafa

    2018-03-01

    Full Text Available Objective: To evaluate the additive value of Contrast Enhanced Spectral Mammography (CESM in the preoperative assessment of malignant lesions in dense breast parenchyma regarding multiplicity. Material and methods: The study included 160 women having heterogeneous dense breast parenchyma (ACR c and d with suspicious lesions identified on sono mammography examination. All patients performed contrast enhanced spectral mammography to confirm or exclude lesion multiplicity. The number of lesions was calculated in the contrast high energy subtraction images with the reference standard being histopathological analysis. Results: Adding CESM to sono-mammography the accuracy in identifying multiple malignant lesion increased from 81.8% accuracy of sono-mammography up to 100% accuracy after adding CESM. Conclusion: Contrast enhanced spectral mammogram showed an added value in the preoperative assessment of breast masses increasing the accuracy of detection of lesions and multiplicity (multifocality and multi-centricity. Keywords: Breast cancer, Contrast enhanced spectral mammogram

  10. Experiment study on the thick GEM-like multiplier for X-ray photoelectrons energy deposition gaining

    International Nuclear Information System (INIS)

    Zhu Pengfei; Ye Yan; Long Yan; Cao Ningxiang; Jia Xing; Li Jianfeng

    2009-01-01

    The GEM is a novel detector with high gain,high time and location resolution. Imitating the structure of the GEM, a thick GEM-like multiplier which has the similar function with that of the GEM is designed and manufactured. The characteristics of the thick GEM-like multiplier increasing electron energy deposition in absorbing medium has been experimentally studied. The results indicate that the energy deposition gain of x-ray photoelectron in medium is apparent, and the maximum energy deposition can increase by more than 40%. Some suggestions of further increasing the energy deposition are given, and the future application of the way of increasing the x-ray photoelectron energy deposition by the thick GEM-like multiplier in hard x-ray imaging is prospected. (authors)

  11. Input/output Buffer based Vedic Multiplier Design for Thermal Aware Energy Efficient Digital Signal Processing on 28nm FPGA

    DEFF Research Database (Denmark)

    Goswami, Kavita; Pandey, Bishwajeet; Hussain, Dil muhammed Akbar

    2016-01-01

    Multiplier is used for multiplication of a signal and a constant in digital signal processing (DSP). 28nm technology based Vedic multiplier is implemented with use of VHDL HDL, Xilinx ISE, Kintex-7 FPGA and XPower Analyzer. Vedic multiplier gain speed improvements by parallelizing the generation...... Programmable Gate Array (FPGA) in order to reduce the development cost. The development cost for Application Specific Integrated Circuits (ASICs) are high in compare to FPGA. Selection of the most energy efficient IO standards in place of signal gating is the main design methodology for design of energy...... efficient Vedic multiplier.There is 68.51%, 69.86%, 74.65%, and 78.39% contraction in total power of Vedic multiplier on 28nm Kintex-7 FPGA, when we use HSTL_II in place of HSTL_II_DCI_18 at 56.7oC, 53.5oC, 40oC and 21oC respectively....

  12. Similarity renormalization group evolution of N N interactions within a subtractive renormalization scheme

    Directory of Open Access Journals (Sweden)

    Durães F.O.

    2010-04-01

    Full Text Available We apply the similarity renormalization group (SRG approach to evolve a nucleon-nucleon (N N interaction in leading-order (LO chiral effective field theory (ChEFT, renormalized within the framework of the subtracted kernel method (SKM. We derive a fixed-point interaction and show the renormalization group (RG invariance in the SKM approach. We also compare the evolution of N N potentials with the subtraction scale through a SKM RG equation in the form of a non-relativistic Callan-Symanzik (NRCS equation and the evolution with the similarity cutoff through the SRG transformation.

  13. Estimates for Unimodular Multipliers on Modulation Hardy Spaces

    Directory of Open Access Journals (Sweden)

    Jiecheng Chen

    2013-01-01

    Full Text Available It is known that the unimodular Fourier multipliers eit|Δ|α/2, α>0, are bounded on all modulation spaces Mp,qs for 1≤p,q≤∞. We extend such boundedness to the case of all 00 and obtain the local well-posedness for the Cauchy problem of some nonlinear partial differential equations with fundamental semigroup eit|Δ|α/2.

  14. On the design of a radix-10 online floating-point multiplier

    Science.gov (United States)

    McIlhenny, Robert D.; Ercegovac, Milos D.

    2009-08-01

    This paper describes an approach to design and implement a radix-10 online floating-point multiplier. An online approach is considered because it offers computational flexibility not available with conventional arithmetic. The design was coded in VHDL and compiled, synthesized, and mapped onto a Virtex 5 FPGA to measure cost in terms of LUTs (look-up-tables) as well as the cycle time and total latency. The routing delay which was not optimized is the major component in the cycle time. For a rough estimate of the cost/latency characteristics, our design was compared to a standard radix-2 floating-point multiplier of equivalent precision. The results demonstrate that even an unoptimized radix-10 online design is an attractive implementation alternative for FPGA floating-point multiplication.

  15. Multiplier effects and government assistance to energy megaprojects: An application to Hibernia

    International Nuclear Information System (INIS)

    Feehan, J.P.; Locke, L.W.

    1993-01-01

    Energy megaprojects typically require several years to construct and entail substantial costs. These costs, in the forms of employment, capital equipment and material inputs, are sometimes viewed as benefits. Moreover, the expenditures on these inputs can induce further increases in employment and income. On the basis of these project-specific and induced effects, government assistance is sometimes sought. The very limiting circumstances under which such government aid is justified are described. Multiplier effects only become relevant if private expenditure would not otherwise occur in some form in the economy. There are contractionary multiplier effects associated with the imposition of taxes to finance the project, and so the two opposing forces may be largely offsetting. Government assistance can only be justified in the presence of unemployment, and where the multiplier effects are large. When these criteria are applied to the Hibernia project, it is found that the project does not generate employment and income effects that are large relative to the total expenditure, or even relative to the level of federal government assistance. The job creation argument for the justification of government assistance to the Hibernia project is very weak. 18 refs., 1 tab

  16. Low-order-mode harmonic multiplying gyrotron traveling-wave amplifier in W band

    International Nuclear Information System (INIS)

    Yeh, Y. S.; Chen, C. H.; Yang, S. J.; Lai, C. H.; Lin, T. Y.; Lo, Y. C.; Hong, J. W.; Hung, C. L.; Chang, T. H.

    2012-01-01

    Harmonic multiplying gyrotron traveling-wave amplifiers (gyro-TWAs) allow for magnetic field reduction and frequency multiplication. To avoid absolute instabilities, this work proposes a W-band harmonic multiplying gyro-TWA operating at low-order modes. By amplifying a fundamental harmonic TE 11 drive wave, the second harmonic component of the beam current initiates a TE 21 wave to be amplified. Absolute instabilities in the gyro-TWA are suppressed by shortening the interaction circuit and increasing wall losses. Simulation results reveal that compared with Ka-band gyro-TWTs, the lower wall losses effectively suppress absolute instabilities in the W-band gyro-TWA. However, a global reflective oscillation occurs as the wall losses decrease. Increasing the length or resistivity of the lossy section can reduce the feedback of the oscillation to stabilize the amplifier. The W-band harmonic multiplying gyro-TWA is predicted to yield a peak output power of 111 kW at 98 GHz with an efficiency of 25%, a saturated gain of 26 dB, and a bandwidth of 1.6 GHz for a 60 kV, 7.5 A electron beam with an axial velocity spread of 8%.

  17. Electronic de-multipliers II (ring-shape systems); Demultiplieurs electroniques II (systeme en anneau)

    Energy Technology Data Exchange (ETDEWEB)

    Raievski, V

    1948-09-01

    This report describes a new type of ring-shape fast electronic counter (de-multiplier) with a resolution capacity equivalent to the one made by Regener (Rev. of Scientific Instruments USA 1946, 17, 180-89) but requiring two-times less electronic valves. This report follows the general description of electronic de-multipliers made by J. Ailloud (CEA--001). The ring comprises 5 flip-flop circuits with two valves each. The different elements of the ring are calculated with enough details to allow the transfer of this calculation to different valve types. (J.S.)

  18. Electronic de-multipliers; Demultiplicateurs electroniques

    Energy Technology Data Exchange (ETDEWEB)

    Ailloud, J

    1948-07-01

    The counting of a huge number of events, randomly or periodically distributed, requires the use of electronic counters which can work with a flow of up to 500000 events per second, while mechanical systems have a much lower resolution which leads to an important percentage of losses (non-counted events). Thus, hybrid systems are generally used which comprise an electronic part with fast counting capabilities but low recording capacities, and a mechanical part for the recording of the successive resets of the electronic part. This report describes the basic elementary circuits of these electronic counters (de-multipliers): dividers by 2 and 5 and flip-flop circuits using triode and pentode valves for the counting of events in the decimal system. (J.S.)

  19. Detection of differential item functioning using Lagrange multiplier tests

    NARCIS (Netherlands)

    Glas, Cornelis A.W.

    1998-01-01

    Abstract: In the present paper it is shown that differential item functioning can be evaluated using the Lagrange multiplier test or Rao’s efficient score test. The test is presented in the framework of a number of IRT models such as the Rasch model, the OPLM, the 2-parameter logistic model, the

  20. Detection of differential item functioning using Lagrange multiplier tests

    NARCIS (Netherlands)

    Glas, Cornelis A.W.

    1996-01-01

    In this paper it is shown that differential item functioning can be evaluated using the Lagrange multiplier test or C. R. Rao's efficient score test. The test is presented in the framework of a number of item response theory (IRT) models such as the Rasch model, the one-parameter logistic model, the

  1. Removing ECG Artifact from the Surface EMG Signal Using Adaptive Subtraction Technique

    Science.gov (United States)

    Abbaspour, S; Fallah, A

    2014-01-01

    Background: The electrocardiogram artifact is a major contamination in the electromyogram signals when electromyogram signal is recorded from upper trunk muscles and because of that the contaminated electromyogram is not useful. Objective: Removing electrocardiogram contamination from electromyogram signals. Methods: In this paper, the clean electromyogram signal, electrocardiogram artifact and electrocardiogram signal were recorded from leg muscles, the pectoralis major muscle of the left side and V4, respectively. After the pre-processing, contaminated electromyogram signal is simulated with a combination of clean electromyogram and electrocardiogram artifact. Then, contaminated electromyogram is cleaned using adaptive subtraction method. This method contains some steps; (1) QRS detection, (2) formation of electrocardiogram template by averaging the electrocardiogram complexes, (3) using low pass filter to remove undesirable artifacts, (4) subtraction. Results: Performance of our method is evaluated using qualitative criteria, power spectrum density and coherence and quantitative criteria signal to noise ratio, relative error and cross correlation. The result of signal to noise ratio, relative error and cross correlation is equal to 10.493, 0.04 and %97 respectively. Finally, there is a comparison between proposed method and some existing methods. Conclusion: The result indicates that adaptive subtraction method is somewhat effective to remove electrocardiogram artifact from contaminated electromyogram signal and has an acceptable result. PMID:25505766

  2. Photon Subtraction by Many-Body Decoherence

    DEFF Research Database (Denmark)

    Murray, C. R.; Mirgorodskiy, I.; Tresp, C.

    2018-01-01

    We experimentally and theoretically investigate the scattering of a photonic quantum field from another stored in a strongly interacting atomic Rydberg ensemble. Considering the many-body limit of this problem, we derive an exact solution to the scattering-induced spatial decoherence of multiple...... stored photons, allowing for a rigorous understanding of the underlying dissipative quantum dynamics. Combined with our experiments, this analysis reveals a correlated coherence-protection process in which the scattering from one excitation can shield all others from spatial decoherence. We discuss how...... this effect can be used to manipulate light at the quantum level, providing a robust mechanism for single-photon subtraction, and experimentally demonstrate this capability....

  3. Determination of Ultimate Torque for Multiply Connected Cross Section Rod

    Directory of Open Access Journals (Sweden)

    V. L. Danilov

    2015-01-01

    Full Text Available The aim of this work is to determine load-carrying capability of the multiply cross-section rod. This calculation is based on the model of the ideal plasticity of the material, so that the desired ultimate torque is a torque at which the entire cross section goes into a plastic state.The article discusses the cylindrical multiply cross-section rod. To satisfy the equilibrium equation and the condition of plasticity simultaneously, two stress function Ф and φ are introduced. By mathematical transformations it has been proved that Ф is constant along the path, and a formula to find its values on the contours has been obtained. The paper also presents the rationale of the line of stress discontinuity and obtained relationships, which allow us to derive the equations break lines for simple interaction of neighboring circuits, such as two lines, straight lines and circles, circles and a different sign of the curvature.After substitution into the boundary condition at the end of the stress function Ф and mathematical transformations a formula is obtained to determine the ultimate torque for the multiply cross-section rod.Using the doubly connected cross-section and three-connected cross-section rods as an example the application of the formula of ultimate torque is studied.For doubly connected cross-section rod, the paper offers a formula of the torque versus the radius of the rod, the aperture radius and the distance between their centers. It also clearly demonstrates the torque dependence both on the ratio of the radii and on the displacement of hole. It is shown that the value of the torque is more influenced by the displacement of hole, rather than by the ratio of the radii.For the three-connected cross-section rod the paper shows the integration feature that consists in selection of a coordinate system. As an example, the ultimate torque is found by two methods: analytical one and 3D modeling. The method of 3D modeling is based on the Nadai

  4. Intraarterial digital subtraction angiography applied to diagnosis of hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Nishizawa, Sadahiko; Sano, Akira; Imanaka, Kazufumi; Sasai, Keisuke; Nagae, Toshiyuki; Mizutani, Masaru; Hatabu, Hiroto; Sadatou, Norihiro; Kuroda, Yasumasa

    1985-12-01

    This paper deals with diagnostic values of intraarterial digital subtraction angiography (IADSA) for evaluating hepatocellular carcinoma. The present series consists of 44 patients with hepatocellular carcinoma, who underwent IADSA combined with conventional hepatic angiography 67 times in total. The evaluated vessels by IADSA included 70 hepatic arteries and 36 portal veins. Comparative studies on the image quality of IADSA with conventional angiography were made in referring to the tumor stain for arteriograms and resolution of intrahepatic portal branches for portograms. Diagnostic superiority including equality of DSA image to conventional was noted in arteriograms: 72.7 % in the right lobe and 86 % in the left. Most deteriorated DSA images were caused by misregistration artifacts. IADSA portography revealed basically diagnostic values to demonstrate lobar, segmental or more peripheral branches in about 95 % of cases studied. DSA, characterized by high contrast resolution and real-time subtraction, offered important and effective informations for interventional angiography as well as resectability of the tumors, requiring less contrast medium.

  5. Iodine filter imaging system for subtraction angiography using synchrotron radiation

    Science.gov (United States)

    Umetani, K.; Ueda, K.; Takeda, T.; Itai, Y.; Akisada, M.; Nakajima, T.

    1993-11-01

    A new type of real-time imaging system was developed for transvenous coronary angiography. A combination of an iodine filter and a single energy broad-bandwidth X-ray produces two-energy images for the iodine K-edge subtraction technique. X-ray images are sequentially converted to visible images by an X-ray image intensifier. By synchronizing the timing of the movement of the iodine filter into and out of the X-ray beam, two output images of the image intensifier are focused side by side on the photoconductive layer of a camera tube by an oscillating mirror. Both images are read out by electron beam scanning of a 1050-scanning-line video camera within a camera frame time of 66.7 ms. One hundred ninety two pairs of iodine-filtered and non-iodine-filtered images are stored in the frame memory at a rate of 15 pairs/s. In vivo subtracted images of coronary arteries in dogs were obtained in the form of motion pictures.

  6. Mixed Analog/Digital Matrix-Vector Multiplier for Neural Network Synapses

    DEFF Research Database (Denmark)

    Lehmann, Torsten; Bruun, Erik; Dietrich, Casper

    1996-01-01

    In this work we present a hardware efficient matrix-vector multiplier architecture for artificial neural networks with digitally stored synapse strengths. We present a novel technique for manipulating bipolar inputs based on an analog two's complements method and an accurate current rectifier...

  7. Optimization of Passive Voltage Multipliers for Fast Start-up and Multi-voltage Power Supplies in Electromagnetic Energy Harvesting Systems

    Science.gov (United States)

    Yang, G.; Stark, B. H.; Burrow, S. G.; Hollis, S. J.

    2014-11-01

    This paper demonstrates the use of passive voltage multipliers for rapid start-up of sub-milliwatt electromagnetic energy harvesting systems. The work describes circuit optimization to make as short as possible the transition from completely depleted energy storage to the first powering-up of an actively controlled switched-mode converter. The dependency of the start-up time on component parameters and topologies is derived by simulation and experimentation. The resulting optimized multiplier design reduces the start-up time from several minutes to 1 second. An additional improvement uses the inherent cascade structure of the voltage multiplier to power sub-systems at different voltages. This multi-rail start-up is shown to reduce the circuit losses of the active converter by 72% with respect to the optimized single-rail system. The experimental results provide insight into the multiplier's transient behaviour, including circuit interactions, in a complete harvesting system, and offer important information to optimize voltage multipliers for rapid start-up.

  8. Optimization of Passive Voltage Multipliers for Fast Start-up and Multi-voltage Power Supplies in Electromagnetic Energy Harvesting Systems

    International Nuclear Information System (INIS)

    Yang, G; Stark, B H; Burrow, S G; Hollis, S J

    2014-01-01

    This paper demonstrates the use of passive voltage multipliers for rapid start-up of sub-milliwatt electromagnetic energy harvesting systems. The work describes circuit optimization to make as short as possible the transition from completely depleted energy storage to the first powering-up of an actively controlled switched-mode converter. The dependency of the start-up time on component parameters and topologies is derived by simulation and experimentation. The resulting optimized multiplier design reduces the start-up time from several minutes to 1 second. An additional improvement uses the inherent cascade structure of the voltage multiplier to power sub-systems at different voltages. This multi-rail start-up is shown to reduce the circuit losses of the active converter by 72% with respect to the optimized single-rail system. The experimental results provide insight into the multiplier's transient behaviour, including circuit interactions, in a complete harvesting system, and offer important information to optimize voltage multipliers for rapid start-up

  9. Low rank alternating direction method of multipliers reconstruction for MR fingerprinting.

    Science.gov (United States)

    Assländer, Jakob; Cloos, Martijn A; Knoll, Florian; Sodickson, Daniel K; Hennig, Jürgen; Lattanzi, Riccardo

    2018-01-01

    The proposed reconstruction framework addresses the reconstruction accuracy, noise propagation and computation time for magnetic resonance fingerprinting. Based on a singular value decomposition of the signal evolution, magnetic resonance fingerprinting is formulated as a low rank (LR) inverse problem in which one image is reconstructed for each singular value under consideration. This LR approximation of the signal evolution reduces the computational burden by reducing the number of Fourier transformations. Also, the LR approximation improves the conditioning of the problem, which is further improved by extending the LR inverse problem to an augmented Lagrangian that is solved by the alternating direction method of multipliers. The root mean square error and the noise propagation are analyzed in simulations. For verification, in vivo examples are provided. The proposed LR alternating direction method of multipliers approach shows a reduced root mean square error compared to the original fingerprinting reconstruction, to a LR approximation alone and to an alternating direction method of multipliers approach without a LR approximation. Incorporating sensitivity encoding allows for further artifact reduction. The proposed reconstruction provides robust convergence, reduced computational burden and improved image quality compared to other magnetic resonance fingerprinting reconstruction approaches evaluated in this study. Magn Reson Med 79:83-96, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  10. Fiscal multipliers over the growth cycle : evidence from Malaysia

    OpenAIRE

    Rafiq, Sohrab; Zeufack, Albert

    2012-01-01

    This paper explores the stabilisation properties of fiscal policy in Malaysia using a model incorporating nonlinearities into the dynamic relationship between fiscal policy and real economic activity over the growth cycle. The paper also investigates how output multipliers for government purchases may alter for different components of government spending. The authors find that fiscal polic...

  11. Digital subtraction angiography in pediatric cerebrovascular occlusive disease

    International Nuclear Information System (INIS)

    Faerber, E.N.; Griska, L.A.B.; Swartz, J.D.; Capitanio, M.A.; Popky, G.L.

    1984-01-01

    While conventional angiography has been used to demonstrate cerebrovascular occlusive disease in the past, digital subtraction angiography (DSA) is capable of showing progressive vascular involvement with ease, simplicity, and extremely low morbidity, making it particularly well suited for children and outpatients either alone or coordinated with computed tomography. The authors discuss the usefulness and advantages of DSA as demonstrated in 7 infants and children with hemiplegia, 4 of whom had sickle-cell disease

  12. Short-cut math

    CERN Document Server

    Kelly, Gerard W

    1984-01-01

    Clear, concise compendium of about 150 time-saving math short-cuts features faster, easier ways to add, subtract, multiply, and divide. Each problem includes an explanation of the method. No special math ability needed.

  13. Digital subtraction angiography of the thoracic aorta

    International Nuclear Information System (INIS)

    Grossman, L.B.; Buonocore, E.; Modic, M.T.; Meaney, T.F.

    1984-01-01

    Forty-three patients with acquired and congenital abnormalities of the thoracic aorta were studied using digital subtraction angiography (DSA) after an intravenous bolus injection of 40 ml of contrast material. Abnormalities studied included coarctation, pseudocoarctation, Marfan syndrome, cervical aorta, double aortic arch, aneurysm, dissection, and tumor. Twenty-four patients also had conventional angiography. DSA was accurate in 95% of cases; in the other 5%, involving patients with acute type I dissection, the coronary arteries could not be seen. The authors concluded that in 92% of their patients, DSA could have replaced the standard aortogram

  14. Digital subtraction angiography of the thoracic aorta

    Energy Technology Data Exchange (ETDEWEB)

    Grossman, L.B.; Buonocore, E.; Modic, M.T.; Meaney, T.F.

    1984-02-01

    Forty-three patients with acquired and congenital abnormalities of the thoracic aorta were studied using digital subtraction angiography (DSA) after an intravenous bolus injection of 40 ml of contrast material. Abnormalities studied included coarctation, pseudocoarctation, Marfan syndrome, cervical aorta, double aortic arch, aneurysm, dissection, and tumor. Twenty-four patients also had conventional angiography. DSA was accurate in 95% of cases; in the other 5%, involving patients with acute type I dissection, the coronary arteries could not be seen. The authors concluded that in 92% of their patients, DSA could have replaced the standard aortogram.

  15. Real-time digital x-ray subtraction imaging

    International Nuclear Information System (INIS)

    Mistretta, C.A.; Kruger, R.A.; Houk, T.L.

    1982-01-01

    A method of producing visible difference images derived from an x-ray image of an anatomical subject is described. X-rays are directed through the subject, and the image is converted into television fields comprising trains of analog video signals. The analog signals are converted into digital signals, which are then integrated over a predetermined time corresponding to several television fields. Difference video signals are produced by performing a subtraction between the ongoing video signals and the corresponding integrated signals, and are converted into visible television difference images representing changes in the x-ray image

  16. Clinical application of digital subtraction angiography (DSA)

    International Nuclear Information System (INIS)

    Morimoto, Tadashi; Kaku, Suiei; Morikawa, Eiji

    1984-01-01

    Intra-arterial digital subtraction angiography (IA-DSA) by the direct puncture of the carotid artery was described with special reference to its techniques, and cases were presented. This method was safe and painless and could be performed repeatedly. Cerebral angiographic images obtained by this method were either superior or fully compatible to the conventional cerebral angiography. It is therefore of great diagnostic value and can replace the conventional method. Furthermore, since the pretreatment is unnecessary and the time required is short, IA-DSA can be used as an adjuvant method for emergency diagnosis. (Namekawa, K)

  17. Procedures for imaging of hemodialysis fistulas with particular reference to digital subtraction angiography (DSA)

    International Nuclear Information System (INIS)

    Neufang, K.F.R.; Erasmi-Koerber, H.; Wimmer, G.; Koeln Univ.

    1983-01-01

    All angiographic procedures established for imaging of hemodialysis fistulas, such as direct venous angiography, intravenous subtraction angiography and arteriography by direct puncture of the brachial artery of by Seldinger's transfemoral technique, can also be effected with digital image processing. Depending on the angiographic technique, the use of digital subtraction angiography has several advantages: lower doses and concentrations of the contrast agent, lower risk of complications (thrombosis of the fistula, vasospasm) and freedom from pain. In addition, there is a marked reduction of examination time and film cost. (orig.)

  18. A single injection technique for subtraction of blood background in 131I-hippuran renograms

    International Nuclear Information System (INIS)

    Rutland, M.D.

    1979-01-01

    A method of subtracting blood background during probe-renography is presented which does not require a prior injection of RIHSA and which produces results approximately 11% higher than the RIHSA method. The new method treats the renogram up to two-and-a-half minutes as a combination of a fraction of the blood curve and a fraction of the integral of the blood curve. Analysis of the data, using either a computer or a programmed calculator, enables these two fractions to be calculated, hence producing the 'background subtraction factor' and the 'uptake constant'. (author)

  19. Optimized GF(2k) ONB type I multiplier architecture based on the Massey-Omura multiplication pattern

    International Nuclear Information System (INIS)

    Fournaris, A P; Koufopavlou, O

    2005-01-01

    Multiplication in GF(2 k ) finite fields is becoming rapidly a very promising solution for fast, small, efficient binary algorithms designed for hardware applications. GF(2 k ) finite fields defined over optimal normal bases (ONB) can be very advantageous in term of gates number and multiplication time delay. Many ONB multipliers works have been proposed that use the Massey-Omura multiplication pattern. In this paper, a method for designing type I optimal normal basis multipliers and an optimal normal basis (ONB) type I multiplier hardware architecture is proposed that, through parallelism and pairing categorization of the ONB multiplication table matrix, achieves very interesting results in terms of gate number and multiplication time delay

  20. Evaluation of chronic periapical lesions by digital subtraction radiography by using Adobe Photoshop CS: a technical report.

    Science.gov (United States)

    Carvalho, Fabiola B; Gonçalves, Marcelo; Tanomaru-Filho, Mário

    2007-04-01

    The purpose of this study was to describe a new technique by using Adobe Photoshop CS (San Jose, CA) image-analysis software to evaluate the radiographic changes of chronic periapical lesions after root canal treatment by digital subtraction radiography. Thirteen upper anterior human teeth with pulp necrosis and radiographic image of chronic periapical lesion were endodontically treated and radiographed 0, 2, 4, and 6 months after root canal treatment by using a film holder. The radiographic films were automatically developed and digitized. The radiographic images taken 0, 2, 4, and 6 months after root canal therapy were submitted to digital subtraction in pairs (0 and 2 months, 2 and 4 months, and 4 and 6 months) choosing "image," "calculation," "subtract," and "new document" tools from Adobe Photoshop CS image-analysis software toolbar. The resulting images showed areas of periapical healing in all cases. According to this methodology, the healing or expansion of periapical lesions can be evaluated by means of digital subtraction radiography by using Adobe Photoshop CS software.

  1. Increasing LIGO sensitivity by feedforward subtraction of auxiliary length control noise

    International Nuclear Information System (INIS)

    Meadors, Grant David; Riles, Keith; Kawabe, Keita

    2014-01-01

    LIGO, the Laser Interferometer Gravitational-wave Observatory, has been designed and constructed to measure gravitational wave strain via differential arm length. The LIGO 4 km Michelson arms with Fabry–Perot cavities have auxiliary length control servos for suppressing Michelson motion of the beam-splitter and arm cavity input mirrors, which degrades interferometer sensitivity. We demonstrate how a post facto pipeline improves a data sample from LIGO Science Run 6 with feedforward subtraction. Dividing data into 1024 s windows, we numerically fit filter functions representing the frequency-domain transfer functions from Michelson length channels into the gravitational-wave strain data channel for each window, then subtract the filtered Michelson channel noise (witness) from the strain channel (target). In this paper we describe the algorithm, assess achievable improvements in sensitivity to astrophysical sources, and consider relevance to future interferometry. (paper)

  2. Use of digital subtraction angiography for renal transplant evaluation

    International Nuclear Information System (INIS)

    Fanucci, E.; Orlacchio, A.; Pocek, M.; Svegliati, F.

    1986-01-01

    Intravenous digital subtraction angiography (IVDSA) was used to evaluate 6 renal allograft recipients and 3 potential renal donors. In 4 potential renal donors and in 2 allograft recipients, angiographic data were confirmed by surgery. IVDSA is a safe, accurate, easily performed, outpatient procedure; in our opinion DSA should became the procedure of choice to study vascular anatomy in renal transplant evaluation

  3. Evaluation of carotid vessel wall enhancement with image subtraction after gadobenate dimeglumine-enhanced MR angiography

    International Nuclear Information System (INIS)

    Sardanelli, Francesco; Di Leo, Giovanni; Aliprandi, Alberto; Flor, Nicola; Papini, Giacomo D.E.; Roccatagliata, Luca; Cotticelli, Biagio; Nano, Giovanni; Cornalba, Gianpaolo

    2009-01-01

    Objectives: This study was aimed at testing the value of image subtraction for evaluating carotid vessel wall enhancement in contrast-enhanced MR angiography (MRA). Materials and methods: IRB approval was obtained. The scans of 81 consecutive patients who underwent carotid MRA with 0.1 mmol/kg of gadobenate dimeglumine were reviewed. Axial carotid 3D T1-weighted fast low-angle shot sequence before and 3 min after contrast injection were acquired and subtracted (enhanced minus unenhanced). Vessel wall enhancement was assigned a four-point score using native or subtracted images from 0 (no enhancement) to 3 (strong enhancement). Stenosis degree was graded according to NASCET. Results: With native images, vessel wall enhancement was detected in 20/81 patients (25%) and in 20/161 carotids (12%), and scored 2.0 ± 0.6 (mean ± standard deviation); with subtracted images, in 21/81 (26%) and 22/161 (14%), and scored 2.5 ± 0.6, respectively (P < 0.001, Sign test). The overall stenosis degree distribution was: mild, 41/161 (25%); moderate, 77/161 (48%); severe, 43/161 (27%). Carotids with moderate stenosis showed vessel wall enhancement with a frequency (17/77, 22%) significantly higher than that observed in carotids with mild stenosis (1/41, 2%) (P = 0.005, Fisher exact test) and higher, even though with borderline significance (P = 0.078, Fisher exact test), than that observed in carotids with severe stenosis (4/43, 9%). Conclusion: Roughly a quarter of patients undergoing carotid MRA showed vessel wall enhancement. Image subtraction improved vessel wall enhancement conspicuity. Vessel wall enhancement seems to be an event relatively independent from the degree of stenosis. Further studies are warranted to define the relation between vessel wall enhancement and histopathology, inflammatory status, and instability.

  4. Scintigraphy of the pancreas head

    Energy Technology Data Exchange (ETDEWEB)

    Basse-Cathalinat, B; Beck, C; Ducassou, D; Blanquet, P [Hopital Pellegrin, 33 - Bordeaux (France)

    1975-01-01

    Emphasis is placed on the considerable improvement due to the computer in pancreatic scintigraphy, which has become more exact as a result. A liver subtraction technique is used. From the data acquired in this method two matrices are established, one for selenomethionine 75 and the other for gold 198. For processing the data are integrated in two broad hepatic areas, of coordinates identical in the two scintigrams, and their ratio is found; the computer multiplies the specifically hepatic matrix by this ratio then subtracts one from the two scintigrams thus normalized. The background can be subtracted from the resulting image.

  5. Reduction of Musical Noise in Spectral Subtraction Method Using Subframe Phase Randomization

    Energy Technology Data Exchange (ETDEWEB)

    Seok, J.W.; Bae, K.S. [Kyungpook National University, Taegu (Korea)

    1999-06-01

    The Subframe phase randomization method is applied to the spectral subtraction method to reduce the musical noise in nonvoicing region after speech enhancement. The musical noise in the spectral subtraction method is the result of the narrowband tonal components that appearing somewhat periodically in the spectrogram of unvoiced and silence regions. Thus each synthesis frame in nonvoicing region is divided into several subframes to broaden the narrowband spectrum, and then phases of silence and unvoiced regions are randomized to eliminate the tonal components in the spectrum while keeping the shape of the amplitude spectrum. Performance assessments based on visual inspection of spectrogram, objective measure, and informal subjective listening tests demonstrate the superiority of the proposed algorithm. (author). 7 refs., 5 figs.

  6. Multi-MW K-Band Harmonic Multiplier: RF Source For High-Gradient Accelerator R & D

    Science.gov (United States)

    Solyak, N. A.; Yakovlev, V. P.; Kazakov, S. Yu.; Hirshfield, J. L.

    2009-01-01

    A preliminary design is presented for a two-cavity harmonic multiplier, intended as a high-power RF source for use in experiments aimed at developing high-gradient structures for a future collider. The harmonic multiplier is to produce power at selected frequencies in K-band (18-26.5 GHz) using as an RF driver an XK-5 S-band klystron (2.856 GHz). The device is to be built with a TE111 rotating mode input cavity and interchangeable output cavities running in the TEn11 rotating mode, with n = 7,8,9 at 19.992, 22.848, and 25.704 GHz. An example for a 7th harmonic multiplier is described, using a 250 kV, 20 A injected laminar electron beam; with 10 MW of S-band drive power, 4.7 MW of 20-GHz output power is predicted. Details are described of the magnetic circuit, cavities, and output coupler.

  7. The Relationship Between Problem Size and Fixation Patterns During Addition, Subtraction, Multiplication, and Division

    Directory of Open Access Journals (Sweden)

    Evan T. Curtis

    2016-08-01

    Full Text Available Eye-tracking methods have only rarely been used to examine the online cognitive processing that occurs during mental arithmetic on simple arithmetic problems, that is, addition and multiplication problems with single-digit operands (e.g., operands 2 through 9; 2 + 3, 6 x 8 and the inverse subtraction and division problems (e.g., 5 – 3; 48 ÷ 6. Participants (N = 109 solved arithmetic problems from one of the four operations while their eye movements were recorded. We found three unique fixation patterns. During addition and multiplication, participants allocated half of their fixations to the operator and one-quarter to each operand, independent of problem size. The pattern was similar on small subtraction and division problems. However, on large subtraction problems, fixations were distributed approximately evenly across the three stimulus components. On large division problems, over half of the fixations occurred on the left operand, with the rest distributed between the operation sign and the right operand. We discuss the relations between these eye tracking patterns and other research on the differences in processing across arithmetic operations.

  8. Motion compensation in digital subtraction angiography using graphics hardware.

    Science.gov (United States)

    Deuerling-Zheng, Yu; Lell, Michael; Galant, Adam; Hornegger, Joachim

    2006-07-01

    An inherent disadvantage of digital subtraction angiography (DSA) is its sensitivity to patient motion which causes artifacts in the subtraction images. These artifacts could often reduce the diagnostic value of this technique. Automated, fast and accurate motion compensation is therefore required. To cope with this requirement, we first examine a method explicitly designed to detect local motions in DSA. Then, we implement a motion compensation algorithm by means of block matching on modern graphics hardware. Both methods search for maximal local similarity by evaluating a histogram-based measure. In this context, we are the first who have mapped an optimizing search strategy on graphics hardware while paralleling block matching. Moreover, we provide an innovative method for creating histograms on graphics hardware with vertex texturing and frame buffer blending. It turns out that both methods can effectively correct the artifacts in most case, as the hardware implementation of block matching performs much faster: the displacements of two 1024 x 1024 images can be calculated at 3 frames/s with integer precision or 2 frames/s with sub-pixel precision. Preliminary clinical evaluation indicates that the computation with integer precision could already be sufficient.

  9. Best approximation of the Dunkl Multiplier Operators Tk,ℓ,m

    Directory of Open Access Journals (Sweden)

    Fethi Soltani

    2015-03-01

    Full Text Available We study some class of Dunkl multiplier operators Tk,ℓ,m; and we give for them an application of the theory of reproducing kernels to the Tikhonov regularization,which gives the best approximation of the operators Tk,ℓ,m on a Hilbert spaces Hskℓ.

  10. Time-area efficient multiplier-free filter architectures for FPGA implementation

    DEFF Research Database (Denmark)

    Shajaan, Mohammad; Nielsen, Karsten; Sørensen, John Aasted

    1995-01-01

    Simultaneous design of multiplier-free filters and their hardware implementation in Xilinx field programmable gate array (XC4000) is presented. The filter synthesis method is a new approach based on cascade coupling of low order sections. The complexity of the design algorithm is 𝒪 (filter o...

  11. Ultra-low-power, class-AB, CMOS four-quadrant current multiplier

    NARCIS (Netherlands)

    Sawigun, C.; Serdijn, W.A.

    2009-01-01

    A class-AB four-quadrant current multiplier constituted by a class-AB current amplifier and a current splitter which can handle input signals in excess of ten times the bias current is presented. The proposed circuit operation is based on the exponential characteristic of BJTs or subthreshold

  12. Imaging moving objects from multiply scattered waves and multiple sensors

    International Nuclear Information System (INIS)

    Miranda, Analee; Cheney, Margaret

    2013-01-01

    In this paper, we develop a linearized imaging theory that combines the spatial, temporal and spectral components of multiply scattered waves as they scatter from moving objects. In particular, we consider the case of multiple fixed sensors transmitting and receiving information from multiply scattered waves. We use a priori information about the multipath background. We use a simple model for multiple scattering, namely scattering from a fixed, perfectly reflecting (mirror) plane. We base our image reconstruction and velocity estimation technique on a modification of a filtered backprojection method that produces a phase-space image. We plot examples of point-spread functions for different geometries and waveforms, and from these plots, we estimate the resolution in space and velocity. Through this analysis, we are able to identify how the imaging system depends on parameters such as bandwidth and number of sensors. We ultimately show that enhanced phase-space resolution for a distribution of moving and stationary targets in a multipath environment may be achieved using multiple sensors. (paper)

  13. Closing of Coster-Kronig transitions in multiply ionised gold atoms

    International Nuclear Information System (INIS)

    Banas, D.; Braziewicz, J.; Czarnota, M.; Fijal, I.; Jaskola, M.; Korman, A.; Kretschmer, W.; Pajek, M.; Semaniak, J.

    2003-01-01

    The paper discusses the effect of closing of L- and M-shell Coster-Kronig (CK) transitions in multiply ionised Au atoms, for which the selected CK transitions become energetically forbidden. This effect plays an important role when the Coster-Kronig energy for single-hole configuration is relatively low, being comparable with a change of the electronic binding energies in multiply ionised atom. We show, by using a simplified model, that for gold the effect of closing of CK transitions occurs for strong L 1 -L 3 M 4,5 transition for the L 1 -subshell as well as the M 3 -M 5 N 6,7 and M 4 -M 5 O 3,4 CK transitions for the M 3 - and M 4 -subshell, respectively. We demonstrate that the discussed effect of closing CK transitions substantially changes the X-ray fluorescence and Coster-Kronig yields and thus has to be considered in interpretation of X-rays excited by heavy ion impact

  14. A novel approach to background subtraction in contrast-enhanced dual-energy digital mammography with commercially available mammography devices: Noise minimization

    International Nuclear Information System (INIS)

    Contillo, Adriano; Di Domenico, Giovanni; Cardarelli, Paolo; Gambaccini, Mauro; Taibi, Angelo

    2016-01-01

    Purpose: Dual-energy image subtraction represents a useful tool to improve the detectability of small lesions, especially in dense breasts. A feature it shares with all x-ray imaging techniques is the appearance of fluctuations in the texture of the background, which can obscure the visibility of interesting details. The aim of the work is to investigate the main noise sources, in order to create a better performing subtraction mechanism. In particular, the structural noise cancellation was achieved by means of a suitable extension of the dual-energy algorithm. Methods: The effect of the cancellation procedure was tested on an analytical simulation of a target with varying structural composition. Subsequently, the subtraction algorithm was also applied to a set of actual radiographs of a breast phantom exhibiting a nonuniform background pattern. The background power spectra of the outcomes were computed and compared to the ones obtained from a standard subtraction algorithm. Results: The comparison between the standard and the proposed cancellations showed an overall suppression of the magnitudes of the spectra, as well as a flattening of the frequency dependence of the structural component of the noise. Conclusions: The proposed subtraction procedure provides an effective cancellation of the residual background fluctuations. When combined with the polychromatic correction already described in a companion publication, it results in a high performing dual-energy subtraction scheme for commercial mammography units.

  15. A novel approach to background subtraction in contrast-enhanced dual-energy digital mammography with commercially available mammography devices: Noise minimization

    Energy Technology Data Exchange (ETDEWEB)

    Contillo, Adriano, E-mail: contillo@fe.infn.it; Di Domenico, Giovanni; Cardarelli, Paolo; Gambaccini, Mauro; Taibi, Angelo [Dipartimento di Fisica e Scienze della Terra, Università degli Studi di Ferrara, Via Saragat 1, I-44122 Ferrara (Italy)

    2016-06-15

    Purpose: Dual-energy image subtraction represents a useful tool to improve the detectability of small lesions, especially in dense breasts. A feature it shares with all x-ray imaging techniques is the appearance of fluctuations in the texture of the background, which can obscure the visibility of interesting details. The aim of the work is to investigate the main noise sources, in order to create a better performing subtraction mechanism. In particular, the structural noise cancellation was achieved by means of a suitable extension of the dual-energy algorithm. Methods: The effect of the cancellation procedure was tested on an analytical simulation of a target with varying structural composition. Subsequently, the subtraction algorithm was also applied to a set of actual radiographs of a breast phantom exhibiting a nonuniform background pattern. The background power spectra of the outcomes were computed and compared to the ones obtained from a standard subtraction algorithm. Results: The comparison between the standard and the proposed cancellations showed an overall suppression of the magnitudes of the spectra, as well as a flattening of the frequency dependence of the structural component of the noise. Conclusions: The proposed subtraction procedure provides an effective cancellation of the residual background fluctuations. When combined with the polychromatic correction already described in a companion publication, it results in a high performing dual-energy subtraction scheme for commercial mammography units.

  16. Modeling radiative transfer with the doubling and adding approach in a climate GCM setting

    Science.gov (United States)

    Lacis, A. A.

    2017-12-01

    The nonlinear dependence of multiply scattered radiation on particle size, optical depth, and solar zenith angle, makes accurate treatment of multiple scattering in the climate GCM setting problematic, due primarily to computational cost issues. In regard to the accurate methods of calculating multiple scattering that are available, their computational cost is far too prohibitive for climate GCM applications. Utilization of two-stream-type radiative transfer approximations may be computationally fast enough, but at the cost of reduced accuracy. We describe here a parameterization of the doubling/adding method that is being used in the GISS climate GCM, which is an adaptation of the doubling/adding formalism configured to operate with a look-up table utilizing a single gauss quadrature point with an extra-angle formulation. It is designed to closely reproduce the accuracy of full-angle doubling and adding for the multiple scattering effects of clouds and aerosols in a realistic atmosphere as a function of particle size, optical depth, and solar zenith angle. With an additional inverse look-up table, this single-gauss-point doubling/adding approach can be adapted to model fractional cloud cover for any GCM grid-box in the independent pixel approximation as a function of the fractional cloud particle sizes, optical depths, and solar zenith angle dependence.

  17. DESIGN STUDY: INTEGER SUBTRACTION OPERATION TEACHING LEARNING USING MULTIMEDIA IN PRIMARY SCHOOL

    Directory of Open Access Journals (Sweden)

    Rendi Muhammad Aris

    2016-12-01

    Full Text Available This study aims to develop a learning trajectory to help students understand concept of subtraction of integers using multimedia in the fourth grade. This study is thematic integrative learning in Curriculum 2013 PMRI based. The method used is design research consists of three stages; preparing for the experiment, design experiment, retrospective analysis. The studied was conducted on 20 students of grade four SDN 1 Muara Batun, OKI. The activities of students in this study consisted of six learning trajectories. The first activity asks the students to classify heroism and non-heroism acts, summarize, and classify integers and non-integer. The second activity asks the students to answer the questions in the film given. The third activity asks students to count the remaining gravel in the film. The fourth activity asks students to count remaining spent money in the film. The fifth activity invites students to play rubber seeds in the bag. The last activity asks students to answer the questions in the student worksheet. The media used along the learning activities are a ruler, rubber seed, student worksheet, money, gravel, and film. The results indicate that the learning trajectory using multimedia help students understand the concept of integer subtraction integer. Keywords: Subtraction Integer, PMRI, Multimedia DOI: http://dx.doi.org/10.22342/jme.8.1.3233.95-102

  18. Intravenous digital subtraction angiography investigation of reversible cerebral ischemia

    International Nuclear Information System (INIS)

    Pistolesi, G.F.; Maso, R.; Filosto, L.; Piovan, E.; Morgante, D.; Taddei, G.; Tonegutti, M.; Portuese, A.

    1986-01-01

    The brachio-cephalic, carotid, vertebral and intra-cranial vessels of 497 patients presenting reversible ischemic attacks (R.I.A) were evaluated with venous digital subtraction angiography (V.D.S.A.). Alterations of the vascular wall were observed in 289/497 (58.2%) patients, of whom 60% presented multiple locations (539 lesions): obstruction (12%), stenosis >50% (29%), stenosis 50%. The incidence of vascular lesions was higher (p [fr

  19. Segmentation of Moving Object Using Background Subtraction Method in Complex Environments

    Directory of Open Access Journals (Sweden)

    S. Kumar

    2016-06-01

    Full Text Available Background subtraction is an extensively used approach to localize the moving object in a video sequence. However, detecting an object under the spatiotemporal behavior of background such as rippling of water, moving curtain and illumination change or low resolution is not a straightforward task. To deal with the above-mentioned problem, we address a background maintenance scheme based on the updating of background pixels by estimating the current spatial variance along the temporal line. The work is focused to immune the variation of local motion in the background. Finally, the most suitable label assignment to the motion field is estimated and optimized by using iterated conditional mode (ICM under a Markovian framework. Performance evaluation and comparisons with the other well-known background subtraction methods show that the proposed method is unaffected by the problem of aperture distortion, ghost image, and high frequency noise.

  20. Robust formation control of marine surface craft using Lagrange multipliers

    DEFF Research Database (Denmark)

    Ihle, Ivar-Andre F.; Jouffroy, Jerome; Fossen, Thor I.

    2006-01-01

    This paper presents a formation modelling scheme based on a set of inter-body constraint functions and Lagrangian multipliers. Formation control for a °eet of marine craft is achieved by stabilizing the auxiliary constraints such that the desired formation con¯guration appears. In the proposed fr...

  1. [Myocardial perfusion imaging by digital subtraction angiography].

    Science.gov (United States)

    Kadowaki, H; Ishikawa, K; Ogai, T; Katori, R

    1986-03-01

    Several methods of digital subtraction angiography (DSA) were compared to determine which could better visualize regional myocardial perfusion using coronary angiography in seven patients with myocardial infarction, two with angina pectoris and five with normal coronary arteries. Satisfactory DSA was judged to be achieved if the shape of the heart on the mask film was identical to that on the live film and if both films were exactly superimposed. To obtain an identical mask film in the shape of each live film, both films were selected from the following three phases of the cardiac cycle; at the R wave of the electrocardiogram, 100 msec before the R wave, and 200 msec before the R wave. The last two were superior for obtaining mask and live films which were similar in shape, because the cardiac motion in these phases was relatively small. Using these mask and live films, DSA was performed either with the continuous image mode (CI mode) or the time interval difference mode (TID mode). The overall perfusion of contrast medium through the artery to the vein was adequately visualized using the CI mode. Passage of contrast medium through the artery, capillary and vein was visualized at each phase using TID mode. Subtracted images were displayed and photographed, and the density of the contrast medium was adequate to display contour lines as in a relief map. Using this DSA, it was found that regional perfusion of the contrast medium was not always uniform in normal subjects, depending on the typography of the coronary artery.(ABSTRACT TRUNCATED AT 250 WORDS)

  2. Using a digital signal processor as a data stream controller for digital subtraction angiography

    International Nuclear Information System (INIS)

    Meng, J.D.; Katz, J.E.

    1991-10-01

    High speed, flexibility, and good arithmetic abilities make digital signal processors (DSP) a good choice as input/output controllers for real time applications. The DSP can be made to pre-process data in real time to reduce data volume, to open early windows on what is being acquired and to implement local servo loops. We present an example of a DSP as an input/output controller for a digital subtraction angiographic imaging system. The DSP pre-processes the raw data, reducing data volume by a factor of two, and is potentially capable of producing real-time subtracted images for immediate display

  3. A New Approach for the Discovery of Antibiotics by Targeting Non-Multiplying Bacteria: A Novel Topical Antibiotic for Staphylococcal Infections

    Science.gov (United States)

    Hu, Yanmin; Shamaei-Tousi, Alireza; Liu, Yingjun; Coates, Anthony

    2010-01-01

    In a clinical infection, multiplying and non-multiplying bacteria co-exist. Antibiotics kill multiplying bacteria, but they are very inefficient at killing non-multipliers which leads to slow or partial death of the total target population of microbes in an infected tissue. This prolongs the duration of therapy, increases the emergence of resistance and so contributes to the short life span of antibiotics after they reach the market. Targeting non-multiplying bacteria from the onset of an antibiotic development program is a new concept. This paper describes the proof of principle for this concept, which has resulted in the development of the first antibiotic using this approach. The antibiotic, called HT61, is a small quinolone-derived compound with a molecular mass of about 400 Daltons, and is active against non-multiplying bacteria, including methicillin sensitive and resistant, as well as Panton-Valentine leukocidin-carrying Staphylococcus aureus. It also kills mupirocin resistant MRSA. The mechanism of action of the drug is depolarisation of the cell membrane and destruction of the cell wall. The speed of kill is within two hours. In comparison to the conventional antibiotics, HT61 kills non-multiplying cells more effectively, 6 logs versus less than one log for major marketed antibiotics. HT61 kills methicillin sensitive and resistant S. aureus in the murine skin bacterial colonization and infection models. No resistant phenotype was produced during 50 serial cultures over a one year period. The antibiotic caused no adverse affects after application to the skin of minipigs. Targeting non-multiplying bacteria using this method should be able to yield many new classes of antibiotic. These antibiotics may be able to reduce the rate of emergence of resistance, shorten the duration of therapy, and reduce relapse rates. PMID:20676403

  4. Enhanced fuel production in thorium/lithium hybrid blankets utilizing uranium multipliers

    International Nuclear Information System (INIS)

    Pitulski, R.H.

    1979-10-01

    A consistent neutronics analysis is performed to determine the effectiveness of uranium bearing neutron multiplier zones on increasing the production of U 233 in thorium/lithium blankets for use in a tokamak fusion-fission hybrid reactor. The nuclear performance of these blankets is evaluated as a function of zone thicknesses and exposure by using the coupled transport burnup code ANISN-CINDER-HIC. Various parameters such as U 233 , Pu 239 , and H 3 production rates, the blanket energy multiplication, isotopic composition of the fuels, and neutron leakages into the various zones are evaluated during a 5 year (6 MW.y.m -2 ) exposure period. Although the results of this study were obtained for a tokomak magnetic fusion device, the qualitative behavior associated with the use of the uranium bearing neutron multiplier should be applicable to all fusion-fission hybrids

  5. Preconditioned alternating direction method of multipliers for inverse problems with constraints

    International Nuclear Information System (INIS)

    Jiao, Yuling; Jin, Qinian; Lu, Xiliang; Wang, Weijie

    2017-01-01

    We propose a preconditioned alternating direction method of multipliers (ADMM) to solve linear inverse problems in Hilbert spaces with constraints, where the feature of the sought solution under a linear transformation is captured by a possibly non-smooth convex function. During each iteration step, our method avoids solving large linear systems by choosing a suitable preconditioning operator. In case the data is given exactly, we prove the convergence of our preconditioned ADMM without assuming the existence of a Lagrange multiplier. In case the data is corrupted by noise, we propose a stopping rule using information on noise level and show that our preconditioned ADMM is a regularization method; we also propose a heuristic rule when the information on noise level is unavailable or unreliable and give its detailed analysis. Numerical examples are presented to test the performance of the proposed method. (paper)

  6. Observed travel times for Multiply-reflected ScS waves from a deep-focus earthquake

    Directory of Open Access Journals (Sweden)

    A. F. ESPISOSA

    1966-06-01

    Full Text Available Tlie deep-focus Argentinean earthquake of December 8
    1962, generated multiply reflected ScS phases which were recorded very
    clearly at stations of the IGY and the TJSC&GS standardized worldwide
    networks and at Canadian stations. The data gathered from this earthquake
    for the multiply-reflected ScS and sScS were used to construct the
    travel times and to extend them to shorter epicentral distances. These
    new data brought to light an error in published travel times for the 2(ScS
    phase.

  7. Non-perturbative subtractions in the heavy quark effective field theory

    International Nuclear Information System (INIS)

    Maiani, L.; Martinelli, G.; Sachrajda, C.T.

    1992-01-01

    We demonstrate the presence of ultraviolet power divergences in the O(1/m h ) corrections to matrix elements of hadronic operators containing a heavy quark field (where m h is the mass of the heavy quark). These power divergences must be subtracted non-perturbatively. The implications for lattice computations are discussed in detail. (orig.)

  8. Operator expansions in the minimal subtraction scheme. II. Explicit formulas for coefficient functions

    International Nuclear Information System (INIS)

    Chetyrkin, K.G.

    1989-01-01

    It is shown in an arbitrary model that the coefficient functions of the operator expansion (renormalized in the minimal subtraction scheme) are finite. Explicit formulas convenient for calculating them in practice are obtained. The gluing method and the formalism of the R* operation are used to transform the formulas in such a way that the coefficient functions can be expressed in terms of ordinary diagrams containing neither nonstandard propagators nor an additional loop integration. An important feature of the representation for the coefficient functions is that the R* operation, which subtracts simultaneously the ultraviolet and infrared divergences, guarantees the existence of the coefficient functions in the limit when the dimensional regularization is lifted without any restrictions

  9. Digital subtraction angiography in the evaluation of chemodectomas

    International Nuclear Information System (INIS)

    Vlahos, L.; Papathanasiou, M.; Gouliamos, A.; Dimakakos, P.; Papavassiliou, C.

    1988-01-01

    During the last 2 years eleven patients with surgically confirmed chemodectomas have been investigated by means of digital subtraction angiography (DSA). Seven patients underwent i.v. DSA, which revealed eight carotid body tumours, and in the remaining four with jugulotympanic chemodectomas intra-arterial (i.a.) DSA was performed. We found i.v. DSA an easy and satisfactory method for the investigation of carotid body tumours but when glomus intravagale, tympanicum or jugulare is suspected an i.a. selective injection is required. (orig.) [de

  10. Digital subtraction angiography in the evaluation of chemodectomas

    Energy Technology Data Exchange (ETDEWEB)

    Vlahos, L.; Papathanasiou, M.; Gouliamos, A.; Dimakakos, P.; Papavassiliou, C.

    1988-05-01

    During the last 2 years eleven patients with surgically confirmed chemodectomas have been investigated by means of digital subtraction angiography (DSA). Seven patients underwent i.v. DSA, which revealed eight carotid body tumours, and in the remaining four with jugulotympanic chemodectomas intra-arterial (i.a.) DSA was performed. We found i.v. DSA an easy and satisfactory method for the investigation of carotid body tumours but when glomus intravagale, tympanicum or jugulare is suspected an i.a. selective injection is required.

  11. SIMAC - A phosphoproteomic strategy for the rapid separation of mono-phosphorylated from multiply phosphorylated peptides

    DEFF Research Database (Denmark)

    Thingholm, Tine E; Jensen, Ole N; Robinson, Phillip J

    2008-01-01

    spectrometric analysis, such as immobilized metal affinity chromatography or titanium dioxide the coverage of the phosphoproteome of a given sample is limited. Here we report a simple and rapid strategy - SIMAC - for sequential separation of mono-phosphorylated peptides and multiply phosphorylated peptides from...... and an optimized titanium dioxide chromatographic method. More than double the total number of identified phosphorylation sites was obtained with SIMAC, primarily from a three-fold increase in recovery of multiply phosphorylated peptides....

  12. Construction and partial sequencing of a subtractive library in Calcutta 4 (Musa AA in early stage of infection with Mycosphaerella fijiensis Morelet

    Directory of Open Access Journals (Sweden)

    Milady Mendoza-Rodríguez

    2006-10-01

    Full Text Available The study of genes involved in plant defense response against pathogen attack, is one of most important steps leading to the elucidation of disease resistance molecular mechanisms. The generation of subtracted deoxyribonucleic acid libraries (cDNA, by means of suppression subtractive hybridization technique (SSH, has been used for this purpose. A subtractive hybridization was made between a cDNA population obtained from ‘Calcutta 4’ inoculated leaves with M. fijiensis (CCIBP-Pf83 and a mixture of cDNA from ‘Calcutta 4’ non inoculated leaves and mycelium. Leaves samples were taken at 6, 10 and 12 days after inoculation. The subtracted library was obtained by cloning and transformation of subtracted products and as a result, 600 recombinants clones were obtained. Sequence analysis of sixty nine clones, revealed redundancy of the expressed sequence tags and most of them showed no homology with reported sequences at databases and only 13 % had a high homology with metalothioneins. The results constitute a step in advance in the molecular study of Musa-Mycosphaerella fijiensis interaction. Key words: Banana-Mycosphaerella fijiensis interaction, BlackSigatoka, Musa spp., suppression subtractive hybridization

  13. Angular distribution of 662keV multiply-Compton scattered gamma rays in copper

    International Nuclear Information System (INIS)

    Singh, Manpreet; Singh, Gurvinderjit; Sandhu, B.S.; Singh, Bhajan

    2007-01-01

    The angular distribution of multiple Compton scattering of 662keV gamma photons, obtained from six Curie 137 Cs source, incident on copper scatterer of varying thickness is studied experimentally in both the forward and backward hemispheres. The scattered photons are detected by a 51mmx51mm NaI(Tl) scintillation detector. The full-energy peak corresponding to singly scattered events is reconstructed analytically. We observe that the numbers of multiply scattered events, having same energy as in the singly scattered distribution, first increases with increase in target thickness and then saturate. The optimum thickness at which the multiply scattered events saturate is determined at different scattering angles

  14. Quasiparticle trapping and the quasiparticle multiplier

    International Nuclear Information System (INIS)

    Booth, N.E.

    1987-01-01

    Superconductors and in particular superconducting tunnel junctions can be used to detect phonons, electromagnetic radiation, x rays, and nuclear particles by the mechanism of Cooper-pair breaking to produce excess quasiparticles and phonons. We show that the sensitivity can be increased by a factor of 100 or more by trapping the quasiparticles in another superconductor of lower gap in the region of the tunnel junction. Moreover, if the ratio of the gap energies is >3 a multiplication process can occur due to the interaction of the relaxation phonons. This leads to the concept of the quasiparticle multiplier, a device which could have wider applications than the Gray effect transistor or the quiteron

  15. Multiply charged ions of the oxygen - produced at interaction of laser radiation with two-element solids

    International Nuclear Information System (INIS)

    Bedilov, M.R.; Bedilov, R.M.; Kamalova, J.O.; Davletov, I.Yu.; Matnazarov, A.R.

    2007-01-01

    Full text: The interest to study of the oxygen multiply charged ions spectra produced at interaction laser radiation with one and two-element solids, is associate with possibility of creating laser and inertial thermonuclear syntheses, effective sources of multiply charged ions and nuclei atoms elements, plasma lasers, lasers on multiply charged transition, design of radiation-resistant materials and others. The present time many works is devoted to multiply charged ions, obtained from one element targets. Experimental results of study charge and energy spectra multiply charged ions of the oxygen, formed at interaction laser radiation with one and two-element solids are given in this work. Our experiments, we used installation, which is described in [1]. Neodymium laser had following parameters: wavelength 1.06 μm; intensity q = (0.1 h 1000) GW/sm 2 ; angle of incidence = 180. Were study one element Al, and two-element Al 2 O 3 , Y 2 O 3 targets by a diameter of 10 mm and thickness of 3 mm. Analysis obtained charge and energy spectra of multiply charged ions one (Al) and two-element (Al 2 O 3 , Y 2 O 3 ) targets depending on intensity of laser radiation and targets components reveal the following: - maximal charge number one element target (Al) at q 500 GW/sm 2 is equal Z max = 6 and all peaks corresponding to charge numbers Z = 1 - 6 well resolved, but two-element targets (Al 2 O 3 ) Z max ions Al decrease before 3. Also it is necessary to note that, Z max ions of the oxygen depend on target components. In case Al 2 O 3 and Y 2 O 3 maximal charge number of oxygen ions are equal Z max = 6 and 3, accordingly; - obtained charge and energy spectra of oxygen ions being included in two-element targets, are indicative of that, general regularities of the change Z max , E max and structures charge and energy spectra depending on q laser are saved. However they hang by target components; - common features and some differences of energy spectra multiply charged oxygen ions

  16. GEM the gas electron multiplier

    CERN Document Server

    Sauli, Fabio

    1997-01-01

    We describe the basic structure and operation of a new device, the Gas Electron Multiplier. Consisting in a polymer foil, metal-clad on both sides and perforated by a high density of holes, the GEM mesh allows to pre-amplify charges released in the gas with good uniformity and energy. Coupled to a micro-strip plate, the pre-amplification element allows to preserve high rate capability and resolution at considerably lower operating voltages, thus completely eliminating discharges and instabilities. Several GEM grids can be operated in cascade; charge gains are large enough to allow detection of signals in the ionization mode on the last element, permitting the use of a simple printed circuit as read-out electrode. Two-dimensional read-out can then be easily implemented. A new generation of simple, reliable and cheap fast position sensitive detectors seems at hand.

  17. Digital subtraction angiography (DSA) of the heart and coronary arteries

    International Nuclear Information System (INIS)

    Struyven, J.J.; Delcour, C.; Brion, J.P.; Vandenbosch, G.; Claessens, J.

    1986-01-01

    Digital subtraction angiography has potential advantages over conventional radiography. The removal of background structures makes possible to visualize chambers of the heart, great vessels and coronary arteries with a lower iodine signal than with conventional cineangiography. Digital data used for imaging can been manipulated for assessment and quantitation of the ventricular fonction and the coronary circulation

  18. Multiply ionization of diethyl ether clusters by 532 nm nanosecond laser: The influence of laser intensity and the electron energy distribution

    International Nuclear Information System (INIS)

    Zhang Nazhen; Wang Weiguo; Zhao Wuduo; Han Fenglei; Li Haiyang

    2010-01-01

    Graphical abstract: The formation mechanism for multiply charged ions (C q+ and O q+ (q = 2-4)) were investigated experimentally and theoretically using a dual polarity time-of-flight mass spectrometer when diethyl ether clusters interacted with nanosecond laser pulse. - Abstract: The formation mechanism for multiply charged ions (C q+ and O q+ (q = 2-4)) were investigated using a dual polarity time-of-flight mass spectrometer when diethyl ether clusters interacted with nanosecond laser pulse. The signal intensity of multiply charged ions and electron energy was measured experimentally. It was shown that the intensity of multiply charged ions increased about 50 times when laser intensity increased from 7.6 x 10 9 to 7.0 x 10 10 W/cm 2 , then saturated as laser intensity increased further. It is interesting that the evolution of the mean value of electron energy was same to that of multiply charged ions. The theoretical calculation showed the ionization potential of atomic ions could be significantly decreased due to the effect of Coulomb screening especially at low laser intensity. It indicated that the electron ionization combined with Coulomb screening effect could explain the production of multiply charged ions in nanosecond laser field.

  19. Mass spectrometric determination of magnesium isotopic ratios and its corrections for electron multiplier discrimination and mass fractionation

    International Nuclear Information System (INIS)

    Deng Zhongguo

    1989-01-01

    The mass spectrometric determination of magnesium isotopic ratios by the use of uranyl nitrate added to magnesium samples to act as a binding agent is reported. Prebaking empty filaments and preheating filaments with deposited magnesium samples on its surface in a vacuum are employed to reduce the Na signal from the thenium-ribbon. Methods for correcting magnesium isotopic ratios for electron multiplier discrimination and mass fractionation are described in detail. The results of the determination of natural magnesium isotopic ratios are 25 Mg/ 24 Mg = 0.12660 (1±0.01%) and 26 Mg/ 24 Mg = 0.13938 (1±0.10%). The magnesium isotopic ratios of rich - 26 Mg-2 sample and rich- 25 Mg-1 sample are 24 Mg/ 26 Mg = 0.003463 (1±0.2%), 25 Mg/ 26 Mg = 0.001656 (±0.2%) and 24 Mg/ 25 Mg = 0.006716 (1±0.2%), 26 Mg/ 25 Mg = 0.007264 (1±0.2%) respectively

  20. Radial multipliers on reduced free products of operator algebras

    DEFF Research Database (Denmark)

    Haagerup, Uffe; Møller, Søren

    2012-01-01

    Let AiAi be a family of unital C¿C¿-algebras, respectively, of von Neumann algebras and ¿:N0¿C¿:N0¿C. We show that if a Hankel matrix related to ¿ is trace-class, then there exists a unique completely bounded map M¿M¿ on the reduced free product of the AiAi, which acts as a radial multiplier...

  1. K-edge subtraction synchrotron X-ray imaging in bio-medical research.

    Science.gov (United States)

    Thomlinson, W; Elleaume, H; Porra, L; Suortti, P

    2018-05-01

    High contrast in X-ray medical imaging, while maintaining acceptable radiation dose levels to the patient, has long been a goal. One of the most promising methods is that of K-edge subtraction imaging. This technique, first advanced as long ago as 1953 by B. Jacobson, uses the large difference in the absorption coefficient of elements at energies above and below the K-edge. Two images, one taken above the edge and one below the edge, are subtracted leaving, ideally, only the image of the distribution of the target element. This paper reviews the development of the KES techniques and technology as applied to bio-medical imaging from the early low-power tube sources of X-rays to the latest high-power synchrotron sources. Applications to coronary angiography, functional lung imaging and bone growth are highlighted. A vision of possible imaging with new compact sources is presented. Copyright © 2018 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  2. Auger transitions in singly and multiply ionized atoms

    International Nuclear Information System (INIS)

    Mehlhorn, W.

    1978-01-01

    Some recent progress in Auger and autoionizing electron spectrometry of free metal atoms and of multiply ionized atoms is reviewed. The differences which arise between the spectra of atoms in the gaseous and the solid state are due to solid state effects. This will be shown for Cd as an example. The super Coster-Kronig transitions 3p-3d 2 (hole notation) and Coster-Kronig transitions 3p-3d 4s have been measured and compared with free-atom calculations for free Zn atoms. The experimental width GAMMA(3p)=(2.1+-0.2)eV found for the free atom agrees with the value obtained for solid Zn but is considerably smaller than the theoretical value for the free atom. Autoionizing spectra of Na following an L-shell excitation or ionization by different particles are compared and discussed. The nonisotropic angular distribution of electrons from the transition 2p 5 3s 2 2 Psub(3/2)→2p 6 +e - is compared with theoretical calculations. Two examples for Auger spectrometry of multiply ionized atoms are given: (1) excitation of neon target atoms by light and heavy ions, and (2) excitation of projectile ions Be + and B + in single gas collisions with CH 4 . A strong alignment of the excited atoms has also been found here

  3. Hardware Design and Implementation of Fixed-Width Standard and Truncated 4×4, 6×6, 8×8 and 12×12-BIT Multipliers Using Fpga

    Science.gov (United States)

    Rais, Muhammad H.

    2010-06-01

    This paper presents Field Programmable Gate Array (FPGA) implementation of standard and truncated multipliers using Very High Speed Integrated Circuit Hardware Description Language (VHDL). Truncated multiplier is a good candidate for digital signal processing (DSP) applications such as finite impulse response (FIR) and discrete cosine transform (DCT). Remarkable reduction in FPGA resources, delay, and power can be achieved using truncated multipliers instead of standard parallel multipliers when the full precision of the standard multiplier is not required. The truncated multipliers show significant improvement as compared to standard multipliers. Results show that the anomaly in Spartan-3 AN average connection and maximum pin delay have been efficiently reduced in Virtex-4 device.

  4. Time-area efficient multiplier-free recursive filter architectures for FPGA implementation

    DEFF Research Database (Denmark)

    Shajaan, Mohammad; Sørensen, John Aasted

    1996-01-01

    Simultaneous design of multiplier-free recursive filters (IIR filters) and their hardware implementation in Xilinx field programmable gate array (XC4000) is presented. The hardware design methodology leads to high performance recursive filters with sampling frequencies in the interval 15-21 MHz (...

  5. Fourier Multipliers on Decomposition Spaces of Modulation and Triebel–Lizorkin Type

    DEFF Research Database (Denmark)

    Cleanthous, G.; Georgiadis, Athanasios; Nielsen, Morten

    2018-01-01

    spaces in both the isotropic and an anisotropic setting. We derive a boundedness result for Fourier multipliers on anisotropic decomposition spaces of modulation and Triebel–Lizorkin type. As an application, we obtain equivalent quasi-norm characterizations for this class of decomposition spaces....

  6. Transient phenomena in bounded fast multiplying assemblies

    International Nuclear Information System (INIS)

    Kraft, T.E.

    1976-01-01

    A generalized dispersion formalism is developed in the context of time-, space-, and energy-dependent transport theory. The evolution of the neutron population in a fast multiplying system following an initial burst of neutrons is examined. The generalized dispersion law obtained is an integral equation, in one variable, for the Laplace and Fourier transformed time- and space-dependent sources of fission neutrons. An approximation technique is shown to generate solutions which converge in L 2 norm to the exact solution for exact elastic, exact inelastic, Goertzel-Grueling or Wigner scattering kernels, and any reasonable fission spectrum

  7. Multipliers on Generalized Mixed Norm Sequence Spaces

    Directory of Open Access Journals (Sweden)

    Oscar Blasco

    2014-01-01

    Full Text Available Given 1≤p,q≤∞ and sequences of integers (nkk and (nk′k such that nk≤nk′≤nk+1, the generalized mixed norm space ℓℐ(p,q is defined as those sequences (ajj such that ((∑j∈Ik‍|aj|p1/pk∈ℓq where Ik={j∈ℕ0 s.t. nk≤jmultipliers (ℓℐ(r,s,ℓ(u,v, for different sequences ℐ and of intervals in ℕ0, are determined.

  8. Effects of tritium on electron multiplier performance

    International Nuclear Information System (INIS)

    Kerst, R.A.; Malinowski, M.E.

    1980-01-01

    In developing diagnostic instruments for fusion reactors, it is necessary to measure the effects of tritium contamination on channel electron multipliers (CEM). A CEM was exposed to T 2 pressures of up to 1.5 x 10 -1 Pa, with exposure quantities ranging up to 8800 Pa-s. The counting rate of the CEM is shown to consist of a prompt (Type I) signal caused by gas-phase tritium and a residual (Type II) signal, probably caused by near-surface tritium. The potential for using CEMs for observing the dynamics of tritium adsorption and absorption is discussed

  9. Enhanced fuel production in thorium/lithium hybrid blankets utilizing uranium multipliers

    Energy Technology Data Exchange (ETDEWEB)

    Pitulski, R.H.

    1979-10-01

    A consistent neutronics analysis is performed to determine the effectiveness of uranium bearing neutron multiplier zones on increasing the production of U/sup 233/ in thorium/lithium blankets for use in a tokamak fusion-fission hybrid reactor. The nuclear performance of these blankets is evaluated as a function of zone thicknesses and exposure by using the coupled transport burnup code ANISN-CINDER-HIC. Various parameters such as U/sup 233/, Pu/sup 239/, and H/sup 3/ production rates, the blanket energy multiplication, isotopic composition of the fuels, and neutron leakages into the various zones are evaluated during a 5 year (6 MW.y.m/sup -2/) exposure period. Although the results of this study were obtained for a tokomak magnetic fusion device, the qualitative behavior associated with the use of the uranium bearing neutron multiplier should be applicable to all fusion-fission hybrids.

  10. Evaluation of left ventricular function using digital subtraction ventriculography

    International Nuclear Information System (INIS)

    Yiannikas, J.; Detrano, R.

    1986-01-01

    Digital subtraction ventriculography following injections of contrast via peripheral veins provides excellent images to assess left ventricular function. The images are essentially identical to those following DCV, but allow more uniform mixing of contrast in the left ventricular chamber. Furthermore, few, if any, cardiac arrhythmias occur, hence obviating difficulties that arise from DCV. The spatial resolution of the method is such that regional wall motion assessment of ventricular function is more accurate than that of other noninvasive imaging methods. The use of video-densitometry allows accurate assessment of left ventricular function even when the left ventricular cavity is nonsymmetrically deformed and aneurysmal. In the setting of the cardiac catheterization laboratory, digital ventriculography may provide a safer means of assessing left ventricular function when critical coronary or myocardial disease is present and allows multiple assessments of ventricular function during the same study. Although excellent correlations with standard ventriculography have been noted by all workers, significant discrepancies still exist in individual patients, particularly in the calculations of end diastolic volumes. In the authors experience and in those of most workers, the largest discrepancies existed in patients in whom suboptimal studies are included for analysis. The most frequent reason for the occasional suboptimal study as with all digital subtraction work is the misregistration that results from motion

  11. Non-contrast-enhanced MR angiography in critical limb ischemia: performance of quiescent-interval single-shot (QISS) and TSE-based subtraction techniques

    International Nuclear Information System (INIS)

    Altaha, Mustafa A.; Jaskolka, Jeffrey D.; Tan, Kongteng; Menezes, Ravi J.; Rick, Manuela; Schmitt, Peter; Wintersperger, Bernd J.

    2017-01-01

    The aim of this study was to evaluate diagnostic performance of non-contrast-enhanced 2D quiescent-interval single-shot (QISS) and 3D turbo spin-echo (TSE)-based subtraction magnetic resonance angiography (MRA) in the assessment of peripheral arteries in patients with critical limb ischemia (CLI). Nineteen consecutive patients (74 % male, 72.8 ± 9.9 years) with CLI underwent 2D QISS and 3D TSE-based subtraction MRA at 1.5 T. Axial-overlapping QISS MRA (3 mm/2 mm; 1 x 1 mm 2 ) covered from the toes to the aortic bifurcation while coronal 3D TSE-based subtraction MRA (1.3 x 1.2 x 1.3 mm 3 ) was restricted to the calf only. MRA data sets (two readers) were evaluated for stenosis (≥50 %) and image quality. Results were compared with digital subtraction angiography (DSA). Two hundred and sixty-seven (267) segments were available for MRA-DSA comparison, with a prevalence of stenosis ≥50 % of 41.9 %. QISS MRA was rated as good to excellent in 79.5-96.0 % of segments without any nondiagnostic segments; 89.8-96.1 % of segments in 3D TSE-based subtraction MRA were rated as nondiagnostic or poor. QISS MRA sensitivities and specificities (segmental) were 92 % and 95 %, respectively, for reader one and 81-97 % for reader two. Due to poor image quality of 3D TSE-based subtraction MRA, diagnostic performance measures were not calculated. QISS MRA demonstrates excellent diagnostic performance and higher robustness than 3D TSE-based subtraction MRA in the challenging patient population with CLI. (orig.)

  12. Non-contrast-enhanced MR angiography in critical limb ischemia: performance of quiescent-interval single-shot (QISS) and TSE-based subtraction techniques

    Energy Technology Data Exchange (ETDEWEB)

    Altaha, Mustafa A. [University Health Network, Department of Medical Imaging, Peter Munk Cardiac Centre, Toronto, Ontario (Canada); Jaskolka, Jeffrey D.; Tan, Kongteng; Menezes, Ravi J. [University Health Network, Department of Medical Imaging, Peter Munk Cardiac Centre, Toronto, Ontario (Canada); University of Toronto, Department of Medical Imaging, Toronto, Ontario (Canada); Rick, Manuela; Schmitt, Peter [Siemens Healthcare, Erlangen (Germany); Wintersperger, Bernd J. [University Health Network, Department of Medical Imaging, Peter Munk Cardiac Centre, Toronto, Ontario (Canada); University of Toronto, Department of Medical Imaging, Toronto, Ontario (Canada); Toronto General Hospital, Department of Medical Imaging, Toronto, Ontario (Canada)

    2017-03-15

    The aim of this study was to evaluate diagnostic performance of non-contrast-enhanced 2D quiescent-interval single-shot (QISS) and 3D turbo spin-echo (TSE)-based subtraction magnetic resonance angiography (MRA) in the assessment of peripheral arteries in patients with critical limb ischemia (CLI). Nineteen consecutive patients (74 % male, 72.8 ± 9.9 years) with CLI underwent 2D QISS and 3D TSE-based subtraction MRA at 1.5 T. Axial-overlapping QISS MRA (3 mm/2 mm; 1 x 1 mm{sup 2}) covered from the toes to the aortic bifurcation while coronal 3D TSE-based subtraction MRA (1.3 x 1.2 x 1.3 mm{sup 3}) was restricted to the calf only. MRA data sets (two readers) were evaluated for stenosis (≥50 %) and image quality. Results were compared with digital subtraction angiography (DSA). Two hundred and sixty-seven (267) segments were available for MRA-DSA comparison, with a prevalence of stenosis ≥50 % of 41.9 %. QISS MRA was rated as good to excellent in 79.5-96.0 % of segments without any nondiagnostic segments; 89.8-96.1 % of segments in 3D TSE-based subtraction MRA were rated as nondiagnostic or poor. QISS MRA sensitivities and specificities (segmental) were 92 % and 95 %, respectively, for reader one and 81-97 % for reader two. Due to poor image quality of 3D TSE-based subtraction MRA, diagnostic performance measures were not calculated. QISS MRA demonstrates excellent diagnostic performance and higher robustness than 3D TSE-based subtraction MRA in the challenging patient population with CLI. (orig.)

  13. Shape Analysis of Planar Multiply-Connected Objects Using Conformal Welding.

    Science.gov (United States)

    Lok Ming Lui; Wei Zeng; Shing-Tung Yau; Xianfeng Gu

    2014-07-01

    Shape analysis is a central problem in the field of computer vision. In 2D shape analysis, classification and recognition of objects from their observed silhouettes are extremely crucial but difficult. It usually involves an efficient representation of 2D shape space with a metric, so that its mathematical structure can be used for further analysis. Although the study of 2D simply-connected shapes has been subject to a corpus of literatures, the analysis of multiply-connected shapes is comparatively less studied. In this work, we propose a representation for general 2D multiply-connected domains with arbitrary topologies using conformal welding. A metric can be defined on the proposed representation space, which gives a metric to measure dissimilarities between objects. The main idea is to map the exterior and interior of the domain conformally to unit disks and circle domains (unit disk with several inner disks removed), using holomorphic 1-forms. A set of diffeomorphisms of the unit circle S(1) can be obtained, which together with the conformal modules are used to define the shape signature. A shape distance between shape signatures can be defined to measure dissimilarities between shapes. We prove theoretically that the proposed shape signature uniquely determines the multiply-connected objects under suitable normalization. We also introduce a reconstruction algorithm to obtain shapes from their signatures. This completes our framework and allows us to move back and forth between shapes and signatures. With that, a morphing algorithm between shapes can be developed through the interpolation of the Beltrami coefficients associated with the signatures. Experiments have been carried out on shapes extracted from real images. Results demonstrate the efficacy of our proposed algorithm as a stable shape representation scheme.

  14. Multiplier method may be unreliable to predict the timing of temporary hemiepiphysiodesis for coronal angular deformity.

    Science.gov (United States)

    Wu, Zhenkai; Ding, Jing; Zhao, Dahang; Zhao, Li; Li, Hai; Liu, Jianlin

    2017-07-10

    The multiplier method was introduced by Paley to calculate the timing for temporary hemiepiphysiodesis. However, this method has not been verified in terms of clinical outcome measure. We aimed to (1) predict the rate of angular correction per year (ACPY) at the various corresponding ages by means of multiplier method and verify the reliability based on the data from the published studies and (2) screen out risk factors for deviation of prediction. A comprehensive search was performed in the following electronic databases: Cochrane, PubMed, and EMBASE™. A total of 22 studies met the inclusion criteria. If the actual value of ACPY from the collected date was located out of the range of the predicted value based on the multiplier method, it was considered as the deviation of prediction (DOP). The associations of patient characteristics with DOP were assessed with the use of univariate logistic regression. Only one article was evaluated as moderate evidence; the remaining articles were evaluated as poor quality. The rate of DOP was 31.82%. In the detailed individual data of included studies, the rate of DOP was 55.44%. The multiplier method is not reliable in predicting the timing for temporary hemiepiphysiodesis, even though it is prone to be more reliable for the younger patients with idiopathic genu coronal deformity.

  15. High dynamic range isotope ratio measurements using an analog electron multiplier

    Czech Academy of Sciences Publication Activity Database

    Williams, P.; Lorinčík, Jan; Franzreb, K.; Herwig, R.

    2013-01-01

    Roč. 45, č. 1 (2013), s. 549-552 ISSN 0142-2421 R&D Projects: GA MŠk ME 894 Institutional support: RVO:67985882 Keywords : Isotope ratios * electron multiplier * dynamic range Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 1.393, year: 2013

  16. Four-gate transistor analog multiplier circuit

    Science.gov (United States)

    Mojarradi, Mohammad M. (Inventor); Blalock, Benjamin (Inventor); Cristoloveanu, Sorin (Inventor); Chen, Suheng (Inventor); Akarvardar, Kerem (Inventor)

    2011-01-01

    A differential output analog multiplier circuit utilizing four G.sup.4-FETs, each source connected to a current source. The four G.sup.4-FETs may be grouped into two pairs of two G.sup.4-FETs each, where one pair has its drains connected to a load, and the other par has its drains connected to another load. The differential output voltage is taken at the two loads. In one embodiment, for each G.sup.4-FET, the first and second junction gates are each connected together, where a first input voltage is applied to the front gates of each pair, and a second input voltage is applied to the first junction gates of each pair. Other embodiments are described and claimed.

  17. Supergravity one-loop corrections on AdS7 and AdS3, higher spins and AdS/CFT

    Directory of Open Access Journals (Sweden)

    Matteo Beccaria

    2015-03-01

    Full Text Available As was shown earlier, the one-loop correction in 10d supergravity on AdS5×S5 corresponds to the contributions to the vacuum energy and 4d boundary conformal anomaly which are minus the values for one N=4 Maxwell supermultiplet, thus reproducing the subleading term in the N2−1 coefficient in the dual SU(N SYM theory. We perform similar one-loop computations in 11d supergravity on AdS7×S4 and 10d supergravity on AdS3×S3×T4. In the AdS7 case we find that the corrections to the 6d conformal anomaly a-coefficient and the vacuum energy are again minus the ones for one (2,0 tensor multiplet, suggesting that the total a-anomaly coefficient for the dual (2,0 theory is 4N3−9/4N−7/4 and thus vanishes for N=1. In the AdS3 case the one-loop correction to the vacuum energy or 2d central charge turns out to be equal to that of one free (4,4 scalar multiplet, i.e. is c=+6. This reproduces the subleading term in the central charge c=6(Q1Q5+1 of the dual 2d CFT describing decoupling limit of D5–D1 system. We also present the expressions for the 6d a-anomaly coefficient and vacuum energy contributions of general-symmetry higher spin field in AdS7 and consider their application to tests of vectorial AdS/CFT with the boundary conformal 6d theory represented by free scalars, spinors or rank-2 antisymmetric tensors.

  18. Multiple images of our galaxy in closed, multiply connected cosmologies

    International Nuclear Information System (INIS)

    Fagundes, H.V.

    1985-01-01

    Friedmanian cosmology with multiply connected spatial sections allows multiple images of cosmic sources, in particular of the galaxy itself. This is illustrated with a specific example of a closed hyperbolic model and a brief mention of a spherical model. Such images may eventually become observable (or recognized as such), thus providing a new test of relativistic cosmology. (Author) [pt

  19. A subtraction scheme for computing QCD jet cross sections at NNLO. Integrating the iterated singly-unresolved subtraction terms

    Energy Technology Data Exchange (ETDEWEB)

    Bolzoni, Paolo [Hamburg Univ. (Germany). II. Inst. fuer Theoretische Physik; Somogyi, Gabor [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany); Trocsanyi, Zoltan [Debrecen Univ. (Hungary); Hungarian Academy of Sciences, Debrecen (Hungary). Inst. of Nuclear Research

    2010-11-15

    We perform the integration of all iterated singly-unresolved subtraction terms over the two-particle factorized phase space. We also sum over the unresolved parton flavours. The final result can be written as a convolution (in colour space) of the Born cross section and an insertion operator. We spell out the insertion operator in terms of 24 basic integrals that are defined explicitly. We compute the coefficients of the Laurent-expansion of these integrals in two different ways, with the method of Mellin-Barnes representations and sector decomposition. Finally, we present the Laurentexpansion of the full insertion operator for the specific examples of electron-positron annihilation into two and three jets. (orig.)

  20. A subtraction scheme for computing QCD jet cross sections at NNLO: integrating the iterated singly-unresolved subtraction terms

    Science.gov (United States)

    Bolzoni, Paolo; Somogyi, Gábor; Trócsányi, Zoltán

    2011-01-01

    We perform the integration of all iterated singly-unresolved subtraction terms, as defined in ref. [1], over the two-particle factorized phase space. We also sum over the unresolved parton flavours. The final result can be written as a convolution (in colour space) of the Born cross section and an insertion operator. We spell out the insertion operator in terms of 24 basic integrals that are defined explicitly. We compute the coefficients of the Laurent expansion of these integrals in two different ways, with the method of Mellin-Barnes representations and sector decomposition. Finally, we present the Laurent-expansion of the full insertion operator for the specific examples of electron-positron annihilation into two and three jets.

  1. Enhanced ground bounce noise reduction in a low-leakage CMOS multiplier

    Science.gov (United States)

    Verma, Bipin Kumar; Akashe, Shyam; Sharma, Sanjay

    2015-09-01

    In this paper, various parameters are used to reduce leakage power, leakage current and noise margin of circuits to enhance their performance. A multiplier is proposed with low-leakage current and low ground bounce noise for the microprocessor, digital signal processors (DSP) and graphics engines. The ground bounce noise problem appears when a conventional power-gating circuit transits from sleep-to-active mode. This paper discusses a reduction in leakage current in the stacking power-gating technique by three modes - sleep, active and sleep-to-active. The simulation results are performed on a 4 × 4 carry-save multiplier for leakage current, active power, leakage power and ground bounce noise, and comparison made for different nanoscales. Ground bounce noise is limited to 90%. The leakage current of the circuit is decimated up to 80% and the active power is reduced to 31%. We performed simulations using cadence virtuoso 180 and 45 nm at room temperature at various supply voltages.

  2. Brain MR post-gadolinium contrast in multiple sclerosis: the role of magnetization transfer and image subtraction in detecting more enhancing lesions

    Energy Technology Data Exchange (ETDEWEB)

    Gavra, M.M.; Gouliamos, A.D.; Vlahos, L.J. [Department of Radiology, ' ' Aretaieion' ' Hospital,University of Athens Medical School, Athens (Greece); Voumvourakis, C.; Sfagos, C. [Department of Neurology, ' ' Eginiteion' ' Hospital, University of Athens Medical School, Athens (Greece)

    2004-03-01

    Our purpose was to evaluate the role of magnetization transfer and image subtraction in detecting more enhancing lesions in brain MR imaging of patients with multiple sclerosis (MS). Thirty-one MS patients underwent MR imaging of the brain with T1-weighted spin echo sequences without and with magnetization transfer (MT) using a 1.5 T imager. Both sequences were acquired before and after intravenous injection of a paramagnetic contrast agent. Subtraction images in T1-weighted sequences were obtained by subtracting the pre-contrast images from the post-contrast ones. A significant difference was found between the numbers of enhanced areas in post-gadolinium T1-weighted images without and with MT (p=0.020). The post-gadolinium T1-weighted images with MT allowed the detection of an increased (13) number of enhancing lesions compared with post-gadolinium T1-weighted images without MT. A significant difference was also found between the numbers of enhanced areas in post-gadolinium T1-weighted images without MT and subtraction images without MT (p=0.020). The subtraction images without MT allowed the detection of an increased (10) number of enhancing lesions compared with post-gadolinium T1-weighted images without MT. Magnetization transfer contrast and subtraction techniques appear to be the simplest and least time-consuming applications to improve the conspicuity and detection of contrast-enhancing lesions in patients with MS. (orig.)

  3. Brain MR post-gadolinium contrast in multiple sclerosis: the role of magnetization transfer and image subtraction in detecting more enhancing lesions

    International Nuclear Information System (INIS)

    Gavra, M.M.; Gouliamos, A.D.; Vlahos, L.J.; Voumvourakis, C.; Sfagos, C.

    2004-01-01

    Our purpose was to evaluate the role of magnetization transfer and image subtraction in detecting more enhancing lesions in brain MR imaging of patients with multiple sclerosis (MS). Thirty-one MS patients underwent MR imaging of the brain with T1-weighted spin echo sequences without and with magnetization transfer (MT) using a 1.5 T imager. Both sequences were acquired before and after intravenous injection of a paramagnetic contrast agent. Subtraction images in T1-weighted sequences were obtained by subtracting the pre-contrast images from the post-contrast ones. A significant difference was found between the numbers of enhanced areas in post-gadolinium T1-weighted images without and with MT (p=0.020). The post-gadolinium T1-weighted images with MT allowed the detection of an increased (13) number of enhancing lesions compared with post-gadolinium T1-weighted images without MT. A significant difference was also found between the numbers of enhanced areas in post-gadolinium T1-weighted images without MT and subtraction images without MT (p=0.020). The subtraction images without MT allowed the detection of an increased (10) number of enhancing lesions compared with post-gadolinium T1-weighted images without MT. Magnetization transfer contrast and subtraction techniques appear to be the simplest and least time-consuming applications to improve the conspicuity and detection of contrast-enhancing lesions in patients with MS. (orig.)

  4. Performance of computed tomography for contrast agent concentration measurements with monochromatic x-ray beams: comparison of K-edge versus temporal subtraction

    International Nuclear Information System (INIS)

    Elleaume, H.; Charvet, A.M.; Corde, S.; Esteve, F.; Le Bas, J.F.

    2002-01-01

    We investigated the performance of monochromatic computed tomography for the quantification of contrast agent concentrations. Two subtraction methods (K-edge subtraction and temporal subtraction) were evaluated and compared theoretically and experimentally in terms of detection limit, precision and accuracy. Measurements were performed using synchrotron x-rays with Lucite phantoms (10 cm and 17.5 cm in diameter) containing iodine or gadolinium solutions ranging from 50 μg ml -1 to 5 mg ml -1 . The experiments were carried out using monochromators developed at the European Synchrotron Radiation Facility (ESRF) medical beamline. The phantoms were imaged either above and below the contrast agent K-edge, or before and after the addition of the contrast agent. Both methods gave comparable performance for phantoms less than 10 cm in diameter. For large phantoms, equivalent to a human head, the temporal subtraction is more suitable for detecting elements such as iodine, keeping a reasonable x-ray dose delivered to the phantom. A good agreement was obtained between analytical calculations, simulations and measurements. The beam harmonic content was taken into account in the simulations. It explains the performance degradation with high contrast agent concentrations. The temporal subtraction technique has the advantage of energy tunability and is well suited for imaging elements, such as iodine or gadolinium, in highly absorbing samples. For technical reasons, the K-edge method is preferable when the imaged organ is moving since the two measurements can be performed simultaneously, which is mandatory for obtaining a good subtraction. (author)

  5. Features of destruction of solids by laser radiation in process of formation of multiply charged ions

    International Nuclear Information System (INIS)

    Bedilov, R.M.; Bedilov, M.R.; Sabitov, M.M.; Matnazarov, A.; Niyozov, B.

    2004-01-01

    Full text: It is known, under interaction of laser radiation with solid surface a power density q > 0.01 W/cm 2 are observed destruction of a solid and issue of electrons, ions, neutrals, neutrons, plasmas, and also radiation in a wide ranges of a spectra. Despite of a plenty of works, devoted to study of processes of interaction, the studies of feature of destruction of solids by laser beam in process of formation multiply charged ions are insufficiently investigated. The results of study feature of destruction of solids by laser radiation in process of formation multiply charged ions are given in this work. In our experiments, we used the mass spectrometer with single-channel laser radiation. The laser installation had the following parameters: a power density of laser radiation q=(0.1-50) GW/cm 2 ; the angle of incidence a=18 deg. to the target surface Al, (W). It was obtained experimentally dynamics of morphology of destruction and also mass - charge and energy spectra of multiply charged ions formed under interaction of laser radiation with Al (W) in the intensity range q=(0.1-50) GW/cm 2 . These studies showed features of destruction Al(W) by laser radiation, i.e. invariable of value evaporation mass from a surface of a solid increase as the laser intensity q. But thus temperature a pair increases in accordance with increase of flow density of a laser radiation. Increase of temperature the pair gives in formation of multiply charged plasma. It is typical that, as q of the laser increases the maximum charge number of ions in laser plasma considerably increase and their energy spectra extend toward higher energies. For example, under q=0.1 GW/cm 2 and 50 GW/cm 2 the maximum charge number of ions Al (W) are equal to Z max = 1 and 7, respectively. From the experimental data obtained, we can conclude that, the formed multiply charged plasma practically completely absorption laser radiation and 'shielding' a target surface for various metals at power densities

  6. Subtractive fabrication of ferroelectric thin films with precisely controlled thickness

    Science.gov (United States)

    Ievlev, Anton V.; Chyasnavichyus, Marius; Leonard, Donovan N.; Agar, Joshua C.; Velarde, Gabriel A.; Martin, Lane W.; Kalinin, Sergei V.; Maksymovych, Petro; Ovchinnikova, Olga S.

    2018-04-01

    The ability to control thin-film growth has led to advances in our understanding of fundamental physics as well as to the emergence of novel technologies. However, common thin-film growth techniques introduce a number of limitations related to the concentration of defects on film interfaces and surfaces that limit the scope of systems that can be produced and studied experimentally. Here, we developed an ion-beam based subtractive fabrication process that enables creation and modification of thin films with pre-defined thicknesses. To accomplish this we transformed a multimodal imaging platform that combines time-of-flight secondary ion mass spectrometry with atomic force microscopy to a unique fabrication tool that allows for precise sputtering of the nanometer-thin layers of material. To demonstrate fabrication of thin-films with in situ feedback and control on film thickness and functionality we systematically studied thickness dependence of ferroelectric switching of lead-zirconate-titanate, within a single epitaxial film. Our results demonstrate that through a subtractive film fabrication process we can control the piezoelectric response as a function of film thickness as well as improve on the overall piezoelectric response versus an untreated film.

  7. Quantitative analysis of alveolar bone change following implant placement using intraoral radiographic subtraction

    International Nuclear Information System (INIS)

    Kimura, Hiroyuki; Kanda, Shigenobu; Tanaka, Takemasa

    2002-01-01

    The purpose of this study was to develop a procedure for quantitative analysis using intraoral radiographs of alveolar bone after placement of dental implants and to consider the validity of the method. We evaluated the ten patients (2 males and 8 females, average age: 48.4 years-old), who were treated with dental implant operation in the site of mandibular molar region, since October of 1999 until September of 2000 in Kimura Dental Clinic (Kumamoto, Japan). We evaluated the intraoral radiographs taken pre- and post- operatively and at follow-up examination. To detect alveolar bone change on radiograph, we adopted the digital subtraction method. Although the radiographs were taken under an ordinary technique with cone indicator, we did not apply the standardized technique with fixing material customized for each patient. Therefore, we used geometric correction and density compensation before subtraction. We assessed the basic statistical values (mean, variance, kurtosis and skewness) of the region of interest (ROI) of the subtracted images. Also, we noted PPD (probing pocket depth) and BOP (bleeding on probing) at each site as indicators of clinical findings and all implanted sites were classified according to the PPD or BOP, i.e. PPD increased group ''PPD (+)'' and PPD stable group ''PPD (-)'', likewise BOP positive group ''BOP (+)'' and negative group ''BOP (-)''. We considered the statistical values of ROI in each group and compared these findings. Mean and variance values of PPD (+) were higher than those of PPD (-) and there was a significant difference in mean value (p=0.031). Similarly, mean and variance values of BOP (+) were statistically higher than those of BOP (-) (p=0.041 and p=0.0087, respectively). Concerning kurtosis and skewness, there was no difference between PPD (+) and PPD (-), or between BOP (+) and BOP (-). Using our method, the radiographs taken for follow-up examination could be assessed quantitatively. It is suggested that geometric

  8. Analysis of luminosity distributions of strong lensing galaxies: subtraction of diffuse lensed signal

    Science.gov (United States)

    Biernaux, J.; Magain, P.; Hauret, C.

    2017-08-01

    Context. Strong gravitational lensing gives access to the total mass distribution of galaxies. It can unveil a great deal of information about the lenses' dark matter content when combined with the study of the lenses' light profile. However, gravitational lensing galaxies, by definition, appear surrounded by lensed signal, both point-like and diffuse, that is irrelevant to the lens flux. Therefore, the observer is most often restricted to studying the innermost portions of the galaxy, where classical fitting methods show some instabilities. Aims: We aim at subtracting that lensed signal and at characterising some lenses' light profile by computing their shape parameters (half-light radius, ellipticity, and position angle). Our objective is to evaluate the total integrated flux in an aperture the size of the Einstein ring in order to obtain a robust estimate of the quantity of ordinary (luminous) matter in each system. Methods: We are expanding the work we started in a previous paper that consisted in subtracting point-like lensed images and in independently measuring each shape parameter. We improve it by designing a subtraction of the diffuse lensed signal, based only on one simple hypothesis of symmetry. We apply it to the cases where it proves to be necessary. This extra step improves our study of the shape parameters and we refine it even more by upgrading our half-light radius measurement method. We also calculate the impact of our specific image processing on the error bars. Results: The diffuse lensed signal subtraction makes it possible to study a larger portion of relevant galactic flux, as the radius of the fitting region increases by on average 17%. We retrieve new half-light radii values that are on average 11% smaller than in our previous work, although the uncertainties overlap in most cases. This shows that not taking the diffuse lensed signal into account may lead to a significant overestimate of the half-light radius. We are also able to measure

  9. On bifurcations of a system of cubic differential equations with an integrating multiplier singular along a second-order curve

    Directory of Open Access Journals (Sweden)

    Aleksandr Alekseev

    2015-07-01

    Full Text Available We establish necessary and sufficient conditions for existence of an integrating multiplier of a special form for systems of two cubic differential equations of the first order. We further study bifurcations of such systems with the change of parameters of their integrating multipliers.

  10. Cluster-assistant generation of multiply charged atomic ions in nanosecond laser ionization of seeded methyl iodide beam

    International Nuclear Information System (INIS)

    Luo Xiaolin; Niu Dongmei; Kong Xianglei; Wen Lihua; Liang Feng; Pei Kemei; Wang Bin; Li Haiyang

    2005-01-01

    The photoionization of methyl iodide beam seeded in argon and helium is studied by time-of-flight mass spectrometry using a 25 ns, 532 nm Nd-YAG laser with intensities in the range of 2 x 10 10 -2 x 10 11 W/cm 2 . Multiply charged ions of I q+ (q = 2-3) and C 2+ with tens of eV kinetic energies have been observed when laser interacts with the middle part of the pulsed molecular beam, whose peak profiles are independent on the laser polarization directions. Strong evidences show that these ions are coming from the Coulomb explosion of multiply charged CH 3 I clusters, and laser induced inverse bremsstrahlung absorption of caged electrons plays a key role in the formation of multiply charged ions

  11. Modeling Photo-multiplier Gain and Regenerating Pulse Height Data for Application Development

    Science.gov (United States)

    Aspinall, Michael D.; Jones, Ashley R.

    2018-01-01

    Systems that adopt organic scintillation detector arrays often require a calibration process prior to the intended measurement campaign to correct for significant performance variances between detectors within the array. These differences exist because of low tolerances associated with photo-multiplier tube technology and environmental influences. Differences in detector response can be corrected for by adjusting the supplied photo-multiplier tube voltage to control its gain and the effect that this has on the pulse height spectra from a gamma-only calibration source with a defined photo-peak. Automated methods that analyze these spectra and adjust the photo-multiplier tube bias accordingly are emerging for hardware that integrate acquisition electronics and high voltage control. However, development of such algorithms require access to the hardware, multiple detectors and calibration source for prolonged periods, all with associated constraints and risks. In this work, we report on a software function and related models developed to rescale and regenerate pulse height data acquired from a single scintillation detector. Such a function could be used to generate significant and varied pulse height data that can be used to integration-test algorithms that are capable of automatically response matching multiple detectors using pulse height spectra analysis. Furthermore, a function of this sort removes the dependence on multiple detectors, digital analyzers and calibration source. Results show a good match between the real and regenerated pulse height data. The function has also been used successfully to develop auto-calibration algorithms.

  12. Geometrical accuracy of metallic objects produced with additive or subtractive manufacturing: A comparative in vitro study.

    Science.gov (United States)

    Braian, Michael; Jönsson, David; Kevci, Mir; Wennerberg, Ann

    2018-04-06

    To evaluate the accuracy and precision of objects produced by additive manufacturing systems (AM) for use in dentistry and to compare with subtractive manufacturing systems (SM). Ten specimens of two geometrical objects were produced by five different AM machines and one SM machine. Object A mimics an inlay-shaped object, while object B imitates a four-unit bridge model. All the objects were sorted into different measurement dimensions (x, y, z), linear distances, angles and corner radius. None of the additive manufacturing or subtractive manufacturing groups presented a perfect match to the CAD file with regard to all parameters included in the present study. Considering linear measurements, the precision for subtractive manufacturing group was consistent in all axes for object A, presenting results of additive manufacturing groups had consistent precision in the x-axis and y-axis but not in the z-axis. With regard to corner radius measurements, the SM group had the best overall accuracy and precision for both objects A and B when compared to the AM groups. Within the limitations of this in vitro study, the conclusion can be made that subtractive manufacturing presented overall precision on all measurements below 0.050mm. The AM machines also presented fairly good precision, additive techniques are now being implemented. Thus all these production techniques need to be tested, compared and validated. Copyright © 2018 The Academy of Dental Materials. Published by Elsevier Inc. All rights reserved.

  13. Hairy AdS solitons

    International Nuclear Information System (INIS)

    Anabalón, Andrés; Astefanesei, Dumitru; Choque, David

    2016-01-01

    We construct exact hairy AdS soliton solutions in Einstein-dilaton gravity theory. We examine their thermodynamic properties and discuss the role of these solutions for the existence of first order phase transitions for hairy black holes. The negative energy density associated to hairy AdS solitons can be interpreted as the Casimir energy that is generated in the dual filed theory when the fermions are antiperiodic on the compact coordinate.

  14. Hairy AdS solitons

    Energy Technology Data Exchange (ETDEWEB)

    Anabalón, Andrés, E-mail: andres.anabalon@uai.cl [Departamento de Ciencias, Facultad de Artes Liberales and Facultad de Ingeniería y Ciencias, Universidad Adolfo Ibáñez, Av. Padre Hurtado 750, Viña del Mar (Chile); Astefanesei, Dumitru, E-mail: dumitru.astefanesei@pucv.cl [Instituto de Física, Pontificia Universidad Católica de Valparaíso, Casilla 4059, Valparaíso (Chile); Choque, David, E-mail: brst1010123@gmail.com [Instituto de Física, Pontificia Universidad Católica de Valparaíso, Casilla 4059, Valparaíso (Chile); Universidad Técnica Federico Santa María, Av. España 1680, Valparaíso (Chile)

    2016-11-10

    We construct exact hairy AdS soliton solutions in Einstein-dilaton gravity theory. We examine their thermodynamic properties and discuss the role of these solutions for the existence of first order phase transitions for hairy black holes. The negative energy density associated to hairy AdS solitons can be interpreted as the Casimir energy that is generated in the dual filed theory when the fermions are antiperiodic on the compact coordinate.

  15. The potential for neurovascular intravenous angiography using K-edge digital subtraction angiography

    International Nuclear Information System (INIS)

    Schueltke, E.; Fiedler, S.; Kelly, M.; Griebel, R.; Juurlink, B.; LeDuc, G.; Esteve, F.; Le Bas, J.-F.; Renier, M.; Nemoz, C.; Meguro, K.

    2005-01-01

    Background: Catheterization of small-caliber blood vessels in the central nervous system can be extremely challenging. Alternatively, intravenous (i.v.) administration of contrast agent is minimally invasive and therefore carries a much lower risk for the patient. With conventional X-ray equipment, volumes of contrast agent that could be safely administered to the patient do not allow acquisition of high-quality images after i.v. injection, because the contrast bolus is extremely diluted by passage through the heart. However, synchrotron-based digital K-edge subtraction angiography does allow acquisition of high-quality images after i.v. administration of relatively small doses of contrast agent. Materials and methods: Eight adult male New Zealand rabbits were used for our experiments. Animals were submitted to both angiography with conventional X-ray equipment and synchrotron-based digital subtraction angiography. Results: With conventional X-ray equipment, no contrast was seen in either cerebral or spinal blood vessels after i.v. injection of iodinated contrast agent. However, using K-edge digital subtraction angiography, as little as 1 ml iodinated contrast agent, when administered as i.v. bolus, yielded images of small-caliber blood vessels in the central nervous system (both brain and spinal cord). Conclusions: If it would be possible to image blood vessels of the same diameter in the central nervous system of human patients, the synchrotron-based technique could yield high-quality images at a significantly lower risk for the patient than conventional X-ray imaging. Images could be acquired where catheterization of feeding blood vessels has proven impossible

  16. Time-resolved PHERMEX image restorations constrained with an additional multiply-exposed image

    International Nuclear Information System (INIS)

    Kruger, R.P.; Breedlove, J.R. Jr.; Trussell, H.J.

    1978-06-01

    There are a number of possible industrial and scientific applications of nanosecond cineradiographs. Although the technology exists to produce closely spaced pulses of x rays for this application, the quality of the time-resolved radiographs is severely limited. The limitations arise from the necessity of using a fluorescent screen to convert the transmitted x rays to light and then using electro-optical imaging systems to gate and to record the images with conventional high-speed cameras. It has been proposed that, in addition to the time-resolved images, a conventional multiply exposed radiograph be obtained. This report uses both PHERMEX and conventional photographic simulations to demonstrate that the additional information supplied by the multiply exposed radiograph can be used to improve the quality of digital image restorations of the time-resolved pictures over what could be achieved with the degraded images alone

  17. Characterization of a prototype matrix of Silicon PhotoMultipliers

    Energy Technology Data Exchange (ETDEWEB)

    Dinu, N. [Laboratory of Linear Accelerator (LAL), IN2P3-CNRS, 91898 Orsay (France)], E-mail: dinu@lal.in2p3.fr; Barrillon, P.; Bazin, C. [Laboratory of Linear Accelerator (LAL), IN2P3-CNRS, 91898 Orsay (France); Belcari, N.; Bisogni, M.G. [Universita di Pisa, Dipartimento di Fisica ' E. Fermi' , 56127 Pisa (Italy); INFN, Sezione di Pisa, 56127 Pisa (Italy); Bondil-Blin, S. [Laboratory of Linear Accelerator (LAL), IN2P3-CNRS, 91898 Orsay (France); Boscardin, M. [Fondazione Bruno Kessler (FBK-irst), 38050 Trento (Italy); Chaumat, V. [Laboratory of Linear Accelerator (LAL), IN2P3-CNRS, 91898 Orsay (France); Collazuol, G. [Scuola Normale Superiore (SNS), 56127 Pisa (Italy); INFN, Sezione di Pisa, 56127 Pisa (Italy); De La Taille, C. [Laboratory of Linear Accelerator (LAL), IN2P3-CNRS, 91898 Orsay (France); Del Guerra, A. [Universita di Pisa, Dipartimento di Fisica ' E. Fermi' , 56127 Pisa (Italy); INFN, Sezione di Pisa, 56127 Pisa (Italy); Llosa, G. [Universita di Pisa, Dipartimento di Fisica ' E. Fermi' , 56127 Pisa (Italy); Marcatili, S. [Universita di Pisa, Dipartimento di Fisica ' E. Fermi' , 56127 Pisa (Italy); INFN, Sezione di Pisa, 56127 Pisa (Italy); Melchiorri, M.; Piemonte, C. [Fondazione Bruno Kessler (FBK-irst), 38050 Trento (Italy); Puill, V. [Laboratory of Linear Accelerator (LAL), IN2P3-CNRS, 91898 Orsay (France); Tarolli, A. [Fondazione Bruno Kessler (FBK-irst), 38050 Trento (Italy); Vagnucci, J.F. [Laboratory of Linear Accelerator (LAL), IN2P3-CNRS, 91898 Orsay (France); Zorzi, N. [Fondazione Bruno Kessler (FBK-irst), 38050 Trento (Italy)

    2009-10-21

    This work reports on the electrical as well as the optical characterizations of a prototype matrix of Silicon PhotoMultipliers (SiPM). The electrical test consists of the measurement of the static (breakdown voltage, quenching resistance, post-breakdown dark current) as well as the dynamic characteristics (gain, dark count rate). The optical test consists of the estimation of the photon detection efficiency as a function of wavelength as well as operation voltage.

  18. Characterization of a prototype matrix of Silicon PhotoMultipliers

    International Nuclear Information System (INIS)

    Dinu, N.; Barrillon, P.; Bazin, C.; Belcari, N.; Bisogni, M.G.; Bondil-Blin, S.; Boscardin, M.; Chaumat, V.; Collazuol, G.; De La Taille, C.; Del Guerra, A.; Llosa, G.; Marcatili, S.; Melchiorri, M.; Piemonte, C.; Puill, V.; Tarolli, A.; Vagnucci, J.F.; Zorzi, N.

    2009-01-01

    This work reports on the electrical as well as the optical characterizations of a prototype matrix of Silicon PhotoMultipliers (SiPM). The electrical test consists of the measurement of the static (breakdown voltage, quenching resistance, post-breakdown dark current) as well as the dynamic characteristics (gain, dark count rate). The optical test consists of the estimation of the photon detection efficiency as a function of wavelength as well as operation voltage.

  19. Using the hydrophobic subtraction model to choose orthogonal columns for online comprehensive two-dimensional liquid chromatography

    DEFF Research Database (Denmark)

    Græsbøll, Rune; Nielsen, Nikoline Juul; Christensen, Jan H.

    2014-01-01

    A method for choosing orthogonal columns for a specific sample set in on-line comprehensive two-dimensional liquid chromatography (LC×LC) was developed on the basis of the hydrophobic subtraction model. The method takes into account the properties of the sample analytes by estimating new F...... neutral and 4 acidic oxygenated polycyclic aromatic compounds (PACs) and 3 nitrogen-containing PAC bases was measured isocratically on 12 columns. The isocratic runs were used to determine the hydrophobic subtraction model analyte parameters, and these were used to estimate new F-weights and predict...

  20. AdS solutions through transgression

    International Nuclear Information System (INIS)

    Donos, Aristomenis; Gauntlett, Jerome P.; Kim, Nakwoo

    2008-01-01

    We present new classes of explicit supersymmetric AdS 3 solutions of type IIB supergravity with non-vanishing five-form flux and AdS 2 solutions of D = 11 supergravity with electric four-form flux. The former are dual to two-dimensional SCFTs with (0,2) supersymmetry and the latter to supersymmetric quantum mechanics with two supercharges. We also investigate more general classes of AdS 3 solutions of type IIB supergravity and AdS 2 solutions of D = 11 supergravity which in addition have non-vanishing three-form flux and magnetic four-form flux, respectively. The construction of these more general solutions makes essential use of the Chern-Simons or 'transgression' terms in the Bianchi identity or the equation of motion of the field strengths in the supergravity theories. We construct infinite new classes of explicit examples and for some of the type IIB solutions determine the central charge of the dual SCFTs. The type IIB solutions with non-vanishing three-form flux that we construct include a two-torus, and after two T-dualities and an S-duality, we obtain new AdS 3 solutions with only the NS fields being non-trivial.